WorldWideScience

Sample records for high-rate performance analysis

  1. Performance of high-rate gravel-packed oil wells

    Energy Technology Data Exchange (ETDEWEB)

    Unneland, Trond

    2001-05-01

    Improved methods for the prediction, evaluation, and monitoring of performance in high-rate cased-hole gravel-packed oil wells are presented in this thesis. The ability to predict well performance prior to the gravel-pack operations, evaluate the results after the operation, and monitor well performance over time has been improved. This lifetime approach to performance analysis of gravel-packed oil wells contributes to increase oil production and field profitability. First, analytical models available for prediction of performance in gravel-packed oil wells are reviewed, with particular emphasis on high-velocity flow effects. From the analysis of field data from three North Sea oil fields, improved and calibrated cased-hole gravel-pack performance prediction models are presented. The recommended model is based on serial flow through formation sand and gravel in the perforation tunnels. In addition, new correlations for high-velocity flow in high-rate gravel-packed oil wells are introduced. Combined, this improves the performance prediction for gravel-packed oil wells, and specific areas can be targeted for optimized well design. Next, limitations in the current methods and alternative methods for evaluation and comparison of well performance are presented. The most widely used parameter, the skin factor, remains a convenient and important parameter. However, using the skin concept in direct comparisons between wells with different reservoir properties may result in misleading or even invalid conclusions. A discussion of the parameters affecting the skin value, with a clarification of limitations, is included. A methodology for evaluation and comparison of gravel-packed well performance is presented, and this includes the use of results from production logs and the use of effective perforation tunnel permeability as a parameter. This contributes to optimized operational procedures from well to well and from field to field. Finally, the data sources available for

  2. High rate response of ultra-high-performance fiber-reinforced concretes under direct tension

    Energy Technology Data Exchange (ETDEWEB)

    Tran, Ngoc Thanh [Department of Civil and Environmental Engineering, Sejong University, 98 Gunja-Dong, Gwangjin-Gu, Seoul 143-747 (Korea, Republic of); Tran, Tuan Kiet [Department of Civil and Environmental Engineering, Sejong University, 98 Gunja-Dong, Gwangjin-Gu, Seoul 143-747 (Korea, Republic of); Department of Civil Engineering and Applied Mechanics, Ho Chi Minh City University of Technology and Education, 01 Vo Van Ngan, Thu Duc District, Ho Chi Minh City (Viet Nam); Kim, Dong Joo, E-mail: djkim75@sejong.ac.kr [Department of Civil and Environmental Engineering, Sejong University, 98 Gunja-Dong, Gwangjin-Gu, Seoul 143-747 (Korea, Republic of)

    2015-03-15

    The tensile response of ultra-high-performance fiber-reinforced concretes (UHPFRCs) at high strain rates (5–24 s{sup −} {sup 1}) was investigated. Three types of steel fibers, including twisted, long and short smooth steel fibers, were added by 1.5% volume content in an ultra high performance concrete (UHPC) with a compressive strength of 180 MPa. Two different cross sections, 25 × 25 and 25 × 50 mm{sup 2}, of tensile specimens were used to investigate the effect of the cross section area on the measured tensile response of UHPFRCs. Although all the three fibers generated strain hardening behavior even at high strain rates, long smooth fibers produced the highest tensile resistance at high rates whereas twisted fiber did at static rate. The breakages of twisted fibers were observed from the specimens tested at high strain rates unlike smooth steel fibers. The tensile behavior of UHPFRCs at high strain rates was clearly influenced by the specimen size, especially in post-cracking strength.

  3. Organization of pulse-height analysis programs for high event rates

    Energy Technology Data Exchange (ETDEWEB)

    Cohn, C E [Argonne National Lab., Ill. (USA)

    1976-09-01

    The ability of a pulse-height analysis program to handle high event rates can be enhanced by organizing it so as to minimize the time spent in interrupt housekeeping. Specifically, the routine that services the data-ready interrupt from the ADC should test whether another event is ready before performing the interrupt return.

  4. High-Rate Performance of Muon Drift Tube Detectors

    CERN Document Server

    Schwegler, Philipp

    The Large Hadron Collider (LHC) at the European Centre for Particle Physics, CERN, collides protons with an unprecedentedly high centre-of-mass energy and luminosity. The collision products are recorded and analysed by four big experiments, one of which is the ATLAS detector. In parallel with the first LHC run from 2009 to 2012, which culminated in the discovery of the last missing particle of the Standard Model of particle physics, the Higgs boson, planning of upgrades of the LHC for higher instantaneous luminosities (HL-LHC) is already progressing. The high instantaneous luminosity of the LHC puts high demands on the detectors with respect to radiation hardness and rate capability which are further increased with the luminosity upgrade. In this thesis, the limitations of the Muon Drift Tube (MDT) chambers of the ATLAS Muon Spectrometer at the high background counting rates at the LHC and performance of new small diameter muon drift tube (sMDT) detectors at the even higher background rates at HL-LHC are stud...

  5. High-rate performance of muon drift tube detectors

    International Nuclear Information System (INIS)

    Schwegler, Philipp

    2014-01-01

    The Large Hadron Collider (LHC) at the European Centre for Particle Physics, CERN, collides protons with an unprecedentedly high centre-of-mass energy and luminosity. The collision products are recorded and analysed by four big experiments, one of which is the ATLAS detector. In parallel with the first LHC run from 2009 to 2012, which culminated in the discovery of the last missing particle of the Standard Model of particle physics, the Higgs boson, planning of upgrades of the LHC for higher instantaneous luminosities (HL-LHC) is already progressing. The high instantaneous luminosity of the LHC puts high demands on the detectors with respect to radiation hardness and rate capability which are further increased with the luminosity upgrade. In this thesis, the limitations of the Muon Drift Tube (MDT) chambers of the ATLAS Muon Spectrometer at the high background counting rates at the LHC and performance of new small diameter muon drift tube (sMDT) detectors at the even higher background rates at HL-LHC are studied. The resolution and efficiency of sMDT chambers at high γ-ray and proton irradiation rates well beyond the ones expected at HL-LHC have been measured and the irradiation effects understood using detailed simulations. The sMDT chambers offer an about an order of magnitude better rate capability and are an ideal replacement for the MDT chambers because of compatibility of services and read-out. The limitations of the sMDT chambers are now in the read-out electronics, taken from the MDT chambers, to which improvements for even higher rate capability are proposed.

  6. Potassium vapor assisted preparation of highly graphitized hierarchical porous carbon for high rate performance supercapacitors

    Science.gov (United States)

    Liu, Zheng; Zeng, Ying; Tang, Qunli; Hu, Aiping; Xiao, Kuikui; Zhang, Shiying; Deng, Weina; Fan, Binbin; Zhu, Yanfei; Chen, Xiaohua

    2017-09-01

    Ultrahigh graphitized carbon microspheres with rich hierarchical pores (AGHPCM-1) have been successfully synthesized through the one-step activation-carbonization strategy (OACS) with porous sulfonated poly-divinylbenzene as the carbon precursor, iron as the hard template and catalyst, and potassium hydroxide (KOH) as activation agent. Through the XRD, TEM, Raman and BET analysis, AGHPCM-1 shows very high graphitization degree and rich micro-, meso- and macro-pores. More importantly, the mechanism for KOH to improve the graphitization degree of carbon materials in OACS has been illustrated by the thermodynamical theory. The tremendous heat releasing from the reaction between the catalyst precursor of Fe2O3 and potassium vapor plays a key role in the formation of graphitized carbon. It may provide a general direction to prepare highly graphitized porous carbon at a moderate temperature. Integrating the advantages of high graphitization degree and rich hierarchical porous structure, the AGHPCM-1 exhibits an excellent rate performance with a response to up to the high current density of 150 A g-1 and high scan rate of 2000 mV s-1. No obvious capacitance decay can be observed after 10000 charge/discharge cycles even at the high current density of 20 A g-1.

  7. MDT Performance in a High Rate Background Environment

    CERN Document Server

    Aleksa, Martin; Hessey, N P; Riegler, W

    1998-01-01

    A Cs137 gamma source with different lead filters in the SPS beam-line X5 has been used to simulate the ATLAS background radiation. This note shows the impact of high background rates on the MDT efficiency and resolution for three kinds of pulse shaping and compares the results with GARFIELD simulations. Furthermore it explains how the performance can be improved by time slewing corrections and double track separation.

  8. Cost minimization analysis of high-dose-rate versus low-dose-rate brachytherapy in endometrial cancer

    International Nuclear Information System (INIS)

    Pinilla, James

    1998-01-01

    Purpose: Endometrial cancer is a common, usually curable malignancy whose treatment frequently involves low-dose-rate (LDR) or high-dose-rate (HDR) brachytherapy. These treatments involve substantial resource commitments and this is increasingly important. This paper presents a cost minimization analysis of HDR versus LDR brachytherapy in the treatment of endometrial cancer. Methods and Materials: The perspective of the analysis is that of the payor, in this case the Ministry of Health. One course of LDR treatment is compared to two courses of HDR treatment. The two alternatives are considered to be comparable with respect to local control, survival, and toxicities. Labor, overhead, and capital costs are accounted for and carefully measured. A 5% inflation rate is used where applicable. A univariate sensitivity analysis is performed. Results: The HDR regime is 22% less expensive compared to the LDR regime. This is $991.66 per patient or, based on the current workload of this department (30 patients per year) over the useful lifetime of the after loader, $297,498 over 10 years in 1997 dollars. Conclusion: HDR brachytherapy minimizes costs in the treatment of endometrial cancer relative to LDR brachytherapy. These results may be used by other centers to make rational decisions regarding brachytherapy equipment replacement or acquisition

  9. A new rate-dependent model for high-frequency tracking performance enhancement of piezoactuator system

    Science.gov (United States)

    Tian, Lizhi; Xiong, Zhenhua; Wu, Jianhua; Ding, Han

    2017-05-01

    Feedforward-feedback control is widely used in motion control of piezoactuator systems. Due to the phase lag caused by incomplete dynamics compensation, the performance of the composite controller is greatly limited at high frequency. This paper proposes a new rate-dependent model to improve the high-frequency tracking performance by reducing dynamics compensation error. The rate-dependent model is designed as a function of the input and input variation rate to describe the input-output relationship of the residual system dynamics which mainly performs as phase lag in a wide frequency band. Then the direct inversion of the proposed rate-dependent model is used to compensate the residual system dynamics. Using the proposed rate-dependent model as feedforward term, the open loop performance can be improved significantly at medium-high frequency. Then, combining the with feedback controller, the composite controller can provide enhanced close loop performance from low frequency to high frequency. At the frequency of 1 Hz, the proposed controller presents the same performance as previous methods. However, at the frequency of 900 Hz, the tracking error is reduced to be 30.7% of the decoupled approach.

  10. Reduced graphene oxide aerogel with high-rate supercapacitive performance in aqueous electrolytes

    Science.gov (United States)

    Si, Weijiang; Wu, Xiaozhong; Zhou, Jin; Guo, Feifei; Zhuo, Shuping; Cui, Hongyou; Xing, Wei

    2013-05-01

    Reduced graphene oxide aerogel (RGOA) is synthesized successfully through a simultaneous self-assembly and reduction process using hypophosphorous acid and I2 as reductant. Nitrogen sorption analysis shows that the Brunauer-Emmett-Teller surface area of RGOA could reach as high as 830 m2 g-1, which is the largest value ever reported for graphene-based aerogels obtained through the simultaneous self-assembly and reduction strategy. The as-prepared RGOA is characterized by a variety of means such as scanning electron microscopy, transmission electron microscopy, X-ray diffraction, Raman spectroscopy, and X-ray photoelectron spectroscopy. Electrochemical tests show that RGOA exhibits a high-rate supercapacitive performance in aqueous electrolytes. The specific capacitance of RGOA is calculated to be 211.8 and 278.6 F g-1 in KOH and H2SO4 electrolytes, respectively. The perfect supercapacitive performance of RGOA is ascribed to its three-dimensional structure and the existence of oxygen-containing groups.

  11. A digital approach for real time high-rate high-resolution radiation measurements

    International Nuclear Information System (INIS)

    Gerardi, G.; Abbene, L.

    2014-01-01

    Modern spectrometers are currently developed by using digital pulse processing (DPP) systems, showing several advantages over traditional analog electronics. The aim of this work is to present digital strategies, in a time domain, for the development of real time high-rate high-resolution spectrometers. We propose a digital method, based on the single delay line (SDL) shaping technique, able to perform multi-parameter analysis with high performance even at high photon counting rates. A robust pulse shape and height analysis (PSHA), applied on single isolated time windows of the detector output waveforms, is presented. The potentialities of the proposed strategy are highlighted through both theoretical and experimental approaches. To strengthen our approach, the implementation of the method on a real-time system together with some experimental results are presented. X-ray spectra measurements with a semiconductor detector are performed both at low and high photon counting rates (up to 1.1 Mcps)

  12. A digital approach for real time high-rate high-resolution radiation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Gerardi, G.; Abbene, L., E-mail: leonardo.abbene@unipa.it

    2014-12-21

    Modern spectrometers are currently developed by using digital pulse processing (DPP) systems, showing several advantages over traditional analog electronics. The aim of this work is to present digital strategies, in a time domain, for the development of real time high-rate high-resolution spectrometers. We propose a digital method, based on the single delay line (SDL) shaping technique, able to perform multi-parameter analysis with high performance even at high photon counting rates. A robust pulse shape and height analysis (PSHA), applied on single isolated time windows of the detector output waveforms, is presented. The potentialities of the proposed strategy are highlighted through both theoretical and experimental approaches. To strengthen our approach, the implementation of the method on a real-time system together with some experimental results are presented. X-ray spectra measurements with a semiconductor detector are performed both at low and high photon counting rates (up to 1.1 Mcps)

  13. Performance of Drift-Tube Detectors at High Counting Rates for High-Luminosity LHC Upgrades

    CERN Document Server

    Bittner, Bernhard; Kortner, Oliver; Kroha, Hubert; Manfredini, Alessandro; Nowak, Sebastian; Ott, Sebastian; Richter, Robert; Schwegler, Philipp; Zanzi, Daniele; Biebel, Otmar; Hertenberger, Ralf; Ruschke, Alexander; Zibell, Andre

    2016-01-01

    The performance of pressurized drift-tube detectors at very high background rates has been studied at the Gamma Irradiation Facility (GIF) at CERN and in an intense 20 MeV proton beam at the Munich Van-der-Graaf tandem accelerator for applications in large-area precision muon tracking at high-luminosity upgrades of the Large Hadron Collider (LHC). The ATLAS muon drifttube (MDT) chambers with 30 mm tube diameter have been designed to cope with and neutron background hit rates of up to 500 Hz/square cm. Background rates of up to 14 kHz/square cm are expected at LHC upgrades. The test results with standard MDT readout electronics show that the reduction of the drift-tube diameter to 15 mm, while leaving the operating parameters unchanged, vastly increases the rate capability well beyond the requirements. The development of new small-diameter muon drift-tube (sMDT) chambers for LHC upgrades is completed. Further improvements of tracking e?ciency and spatial resolution at high counting rates will be achieved with ...

  14. The Effect of Selected Nonmusical Factors on Adjudicators' Ratings of High School Solo Vocal Performances

    Science.gov (United States)

    Howard, Sandra A.

    2012-01-01

    The purpose of this study was to examine the effect of differentiated performance attire and stage deportment on adjudicators' ratings of high school solo vocal performances. High school choral students (n = 153) and undergraduate (n = 97) and graduate music majors (n = 32) served as adjudicators (N = 282). Adjudicators rated recorded solo vocal…

  15. Geisinger high-risk osteoporosis clinic (HiROC): 2013-2015 FLS performance analysis.

    Science.gov (United States)

    Dunn, P; Webb, D; Olenginski, T P

    2018-02-01

    Geisinger Health System (GHS) high-risk osteoporosis clinic (HiROC), which treats patients with low-trauma, fragility fractures, reports their 2013-2015 performance measures in secondary fracture prevention. This fracture liaison service (FLS) pathway treats 75% of high-risk, drug eligible patients, compared to 13.8% in GHS primary care. This performance points to the need for more FLS programs throughout the world. The purpose of this study is to analyze and report ongoing performance measures in outpatient and inpatient high-risk osteoporosis clinic (HiROC) program designed for patients with low-trauma, fragility fractures. Retrospective chart review of outpatient HiROC (511 patients) and inpatient HiROC (1279 patients) performance from 2013 to 2015 is reported within Geisinger Health System (GHS). Similar to a prior report, we document that Geisinger's branded outpatient and inpatient HiROC pathways continue to function as an all-fracture FLS. Importantly, this analysis emphasizes the importance of FLS care that HiROC's treatment rate of 75% was markedly superior to GHS-PCP care of 13.8%. However, a large percentage of patients (37.8%) were lost to follow-up care. This led to the identification of multiple care gaps/barriers to ideal best practice. FLS programs use case finding strategies and address secondary fracture prevention. GHS HiROC's performance and initiation of drug therapy in this fracture patient population contrasts with GHS-PCP care's much lower rate of treatment, documenting the need for ongoing FLS care. Importantly, the results of this analysis have prompted the beginnings of GHS programmatic changes, designed to narrow the reported care gaps in this mature FLS.

  16. High dose rate versus low dose rate brachytherapy for oral cancer--a meta-analysis of clinical trials.

    Directory of Open Access Journals (Sweden)

    Zhenxing Liu

    Full Text Available To compare the efficacy and safety of high dose rate (HDR and low dose rate (LDR brachytherapy in treating early-stage oral cancer.A systematic search of MEDLINE, EMBASE and Cochrane Library databases, restricted to English language up to June 1, 2012, was performed to identify potentially relevant studies.Only randomized controlled trials (RCT and controlled trials that compared HDR to LDR brachytherapy in treatment of early-stage oral cancer (stages I, II and III were of interest.Two investigators independently extracted data from retrieved studies and controversies were solved by discussion. Meta-analysis was performed using RevMan 5.1. One RCT and five controlled trials (607 patients: 447 for LDR and 160 for HDR met the inclusion criteria. The odds ratio showed no statistically significant difference between LDR group and HDR group in terms of local recurrence (OR = 1.12, CI 95% 0.62-2.01, overall mortality (OR = 1.01, CI 95% 0.61-1.66 and Grade 3/4 complications (OR = 0.86, CI 95% 0.52-1.42.This meta-analysis indicated that HDR brachytherapy was a comparable alternative to LDR brachytherapy in treatment of oral cancer. HDR brachytherapy might become a routine choice for early-stage oral cancer in the future.

  17. Visualization and Data Analysis for High-Performance Computing

    Energy Technology Data Exchange (ETDEWEB)

    Sewell, Christopher Meyer [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-27

    This is a set of slides from a guest lecture for a class at the University of Texas, El Paso on visualization and data analysis for high-performance computing. The topics covered are the following: trends in high-performance computing; scientific visualization, such as OpenGL, ray tracing and volume rendering, VTK, and ParaView; data science at scale, such as in-situ visualization, image databases, distributed memory parallelism, shared memory parallelism, VTK-m, "big data", and then an analysis example.

  18. Development of ultra high speed photographic system using high repetition rate visible laser

    International Nuclear Information System (INIS)

    Lee, Jong Min; Cha, Byung Hun; Kim, Sung Ho; Kim, Jung Bog; Lim, Chang Hwan; Cha, Hyung Ki; Song, Kyu Seok; Lee, Byung Deok; Rhi, Jong Hoon; Baik, Dae Hyun; Han, Jae Min; Rho, Si Pyo; Lee, Byung Cheol; Jeong, Do Yung; Choi, An Seong; Jeong, Chan Ik; Park, Dae Ung; Jeong, Sung Min; Lee, Sang Kil; Kim, Heon Jun; Jang, Rae gak; Jo, Do Hun; Park, Min Young

    1992-12-01

    The goal of this project is to develop and commercialize a high speed photographic system equipped with a high repetition rate visible laser. The developed system provides the characteristics of high time resolution and large number of frames. The system consists of 10 W air cooled CVL or a 30 W water cooled CVL, a rotating drum-type high speed camera with the framing rate of 35,000 fps, and a automatic control device. The system has the performance of 10 nsec time resolution, 35,000 fps framing rate, and 250 picture frames. The high speed photographic systems are widely applied to the fields such as high-efficient engine development, high-speed vibration analysis, shock wave propagation study, flow visualization analysis, weapon development, etc. (Author)

  19. WO{sub 3-x} rate at Au rate at MnO{sub 2} core-shell nanowires on carbon fabric for high-performance flexible supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Xihong; Zhai, Teng [Wuhan National Laboratory for Optoelectronics (WNLO), College of Optoelectronic Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan (China); School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou (China); Zhang, Xianghui; Shen, Yongqi; Yuan, Longyan; Hu, Bin; Gao, Yihua; Zhou, Jun [Wuhan National Laboratory for Optoelectronics (WNLO), College of Optoelectronic Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan (China); Gong, Li; Chen, Jian [Instrumental Analysis and Research Center, Sun Yat-sen University, Guangzhou (China); Tong, Yexiang [School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou (China); Wang, Zhong Lin [Wuhan National Laboratory for Optoelectronics (WNLO), College of Optoelectronic Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan (China); School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia (United States)

    2012-02-14

    WO{sub 3-x} rate at Au rate at MnO{sub 2} core-shell nanowires (NWs) are synthesized on a flexible carbon fabric and show outstanding electrochemical performance in supercapacitors such as high specific capacitance, good cyclic stability, high energy density, and high power density. These results suggest that the WO{sub 3-x} rate at Au rate at MnO{sub 2} NWs have promising potential for use in high-performance flexible supercapacitors. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  20. Ultra-high Performance Liquid Chromatography in Steroid Analysis

    OpenAIRE

    Salonen, Fanny

    2017-01-01

    The latest version of liquid chromatography is ultra-high performance (or pressure) chromatography (UHPLC). In the technique, short and narrow-bore columns with particle sizes below 3 µm are used. The extremely high pressure used results in very short analysis times, excellent separation, and good resolution. This makes UHPLC a good choice for steroidal analysis. Steroids are a highly interesting area of study; they can be recognized as biomarkers for several diseases and are a relevant topic...

  1. Critical Factors Explaining the Leadership Performance of High-Performing Principals

    Science.gov (United States)

    Hutton, Disraeli M.

    2018-01-01

    The study explored critical factors that explain leadership performance of high-performing principals and examined the relationship between these factors based on the ratings of school constituents in the public school system. The principal component analysis with the use of Varimax Rotation revealed that four components explain 51.1% of the…

  2. Improvement on high rate performance of LiFePO4 cathodes using graphene as a conductive agent

    Science.gov (United States)

    Wei, Xufang; Guan, Yibiao; Zheng, Xiaohui; Zhu, Qizhen; Shen, Jinran; Qiao, Ning; Zhou, Shuqin; Xu, Bin

    2018-05-01

    In this work, the electrochemical properties of the LiFePO4 cathode using graphene as a conductive agent were revealed. Compared to the conventional LiFePO4 electrodes with carbon black as a conductive agent, the graphene sheets can establish a more effective conductive framework due to their layered structure and excellent electronic conductivity, leading to better electrochemical rate performance. Furthermore, the obverse of increasing graphene content is continued gains in high-rate performance of the LiFePO4 electrodes. The electrodes with 30 wt% graphene show high capacities up to 103.1 mA h g-1 and 68 mA h g-1 during discharging with extremely high rates of 30 C and 50 C, respectively. Besides, good cycling performance at high rate is also achieved. The electrodes with 30 wt% graphene display a capacity retention higher than 80% after 1000 cycles at 30 C. These results not only indicate that the graphene could be a promising candidate as a conductive agent, but also provide a new insight for designing LiFePO4 electrodes with brilliant high-rate performance via a simple method.

  3. A Lithium-Air Battery Stably Working at High Temperature with High Rate Performance.

    Science.gov (United States)

    Pan, Jian; Li, Houpu; Sun, Hao; Zhang, Ye; Wang, Lie; Liao, Meng; Sun, Xuemei; Peng, Huisheng

    2018-02-01

    Driven by the increasing requirements for energy supply in both modern life and the automobile industry, the lithium-air battery serves as a promising candidate due to its high energy density. However, organic solvents in electrolytes are likely to rapidly vaporize and form flammable gases under increasing temperatures. In this case, serious safety problems may occur and cause great harm to people. Therefore, a kind of lithium-air that can work stably under high temperature is desirable. Herein, through the use of an ionic liquid and aligned carbon nanotubes, and a fiber shaped design, a new type of lithium-air battery that can effectively work at high temperatures up to 140 °C is developed. Ionic liquids can offer wide electrochemical windows and low vapor pressures, as well as provide high thermal stability for lithium-air batteries. The aligned carbon nanotubes have good electric and heat conductivity. Meanwhile, the fiber format can offer both flexibility and weavability, and realize rapid heat conduction and uniform heat distribution of the battery. In addition, the high temperature has also largely improved the specific powers by increasing the ionic conductivity and catalytic activity of the cathode. Consequently, the lithium-air battery can work stably at 140 °C with a high specific current of 10 A g -1 for 380 cycles, indicating high stability and good rate performance at high temperatures. This work may provide an effective paradigm for the development of high-performance energy storage devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Performance analysis for the bit-error rate of SAC-OCDMA systems

    Science.gov (United States)

    Feng, Gang; Cheng, Wenqing; Chen, Fujun

    2015-09-01

    Under low power, Gaussian statistics by invoking the central limit theorem is feasible to predict the upper bound in the spectral-amplitude-coding optical code division multiple access (SAC-OCDMA) system. However, this case severely underestimates the bit-error rate (BER) performance of the system under high power assumption. Fortunately, the exact negative binomial (NB) model is a perfect replacement for the Gaussian model in the prediction and evaluation. Based on NB statistics, a more accurate closed-form expression is analyzed and derived for the SAC-OCDMA system. The experiment shows that the obtained expression provides a more precise prediction of the BER performance under the low and high power assumptions.

  5. RSA prediction of high failure rate for the uncoated Interax TKA confirmed by meta-analysis.

    Science.gov (United States)

    Pijls, Bart G; Nieuwenhuijse, Marc J; Schoones, Jan W; Middeldorp, Saskia; Valstar, Edward R; Nelissen, Rob G H H

    2012-04-01

    In a previous radiostereometric (RSA) trial the uncoated, uncemented, Interax tibial components showed excessive migration within 2 years compared to HA-coated and cemented tibial components. It was predicted that this type of fixation would have a high failure rate. The purpose of this systematic review and meta-analysis was to investigate whether this RSA prediction was correct. We performed a systematic review and meta-analysis to determine the revision rate for aseptic loosening of the uncoated and cemented Interax tibial components. 3 studies were included, involving 349 Interax total knee arthroplasties (TKAs) for the comparison of uncoated and cemented fixation. There were 30 revisions: 27 uncoated and 3 cemented components. There was a 3-times higher revision rate for the uncoated Interax components than that for cemented Interax components (OR = 3; 95% CI: 1.4-7.2). This meta-analysis confirms the prediction of a previous RSA trial. The uncoated Interax components showed the highest migration and turned out to have the highest revision rate for aseptic loosening. RSA appears to enable efficient detection of an inferior design as early as 2 years postoperatively in a small group of patients.

  6. Accelerated Synchrotron X-ray Diffraction Data Analysis on a Heterogeneous High Performance Computing System

    Energy Technology Data Exchange (ETDEWEB)

    Qin, J; Bauer, M A, E-mail: qin.jinhui@gmail.com, E-mail: bauer@uwo.ca [Computer Science Department, University of Western Ontario, London, ON N6A 5B7 (Canada)

    2010-11-01

    The analysis of synchrotron X-ray Diffraction (XRD) data has been used by scientists and engineers to understand and predict properties of materials. However, the large volume of XRD image data and the intensive computations involved in the data analysis makes it hard for researchers to quickly reach any conclusions about the images from an experiment when using conventional XRD data analysis software. Synchrotron time is valuable and delays in XRD data analysis can impact decisions about subsequent experiments or about materials that they are investigating. In order to improve the data analysis performance, ideally to achieve near real time data analysis during an XRD experiment, we designed and implemented software for accelerated XRD data analysis. The software has been developed for a heterogeneous high performance computing (HPC) system, comprised of IBM PowerXCell 8i processors and Intel quad-core Xeon processors. This paper describes the software and reports on the improved performance. The results indicate that it is possible for XRD data to be analyzed at the rate it is being produced.

  7. Accelerated Synchrotron X-ray Diffraction Data Analysis on a Heterogeneous High Performance Computing System

    International Nuclear Information System (INIS)

    Qin, J; Bauer, M A

    2010-01-01

    The analysis of synchrotron X-ray Diffraction (XRD) data has been used by scientists and engineers to understand and predict properties of materials. However, the large volume of XRD image data and the intensive computations involved in the data analysis makes it hard for researchers to quickly reach any conclusions about the images from an experiment when using conventional XRD data analysis software. Synchrotron time is valuable and delays in XRD data analysis can impact decisions about subsequent experiments or about materials that they are investigating. In order to improve the data analysis performance, ideally to achieve near real time data analysis during an XRD experiment, we designed and implemented software for accelerated XRD data analysis. The software has been developed for a heterogeneous high performance computing (HPC) system, comprised of IBM PowerXCell 8i processors and Intel quad-core Xeon processors. This paper describes the software and reports on the improved performance. The results indicate that it is possible for XRD data to be analyzed at the rate it is being produced.

  8. Influence of the electrolyte distribution near the micropores of the activated carbon (AC) electrode on high rate performance of high voltage capacitors

    International Nuclear Information System (INIS)

    Lee, Chung ho; Xu, Fan; Jung, Cheolsoo

    2014-01-01

    Highlights: • TFB can enhance the rate performance of high voltage capacitors. • TFB can suppress to increase the discharge slope to improve the cell performance. • TFB decreases the charge transfer resistance of an AC cell. • TFB affects the distribution of the electrolyte components near the microporous AC. - Abstract: This paper presents a method to enhance the rate performance of high voltage capacitors using an electrolyte additive, 1,3,5-trifluorobenzene (TFB). With increasing discharge rate, the capacity of the activated carbon (AC)/lithium (Li) cell decreases with increasing the slope of the discharge curve and its potential drop at 4.6 V. By adding TFB, the discharge slope improves to increase the rate performance of the cell, and EIS showed that the charge transfer resistance (Rc) of the AC cell decreases. These results suggest that TFB affects the distribution of the electrolyte components near the microporous AC and improves the rate performance of the AC cell

  9. Error-rate performance analysis of opportunistic regenerative relaying

    KAUST Repository

    Tourki, Kamel

    2011-09-01

    In this paper, we investigate an opportunistic relaying scheme where the selected relay assists the source-destination (direct) communication. In our study, we consider a regenerative opportunistic relaying scheme in which the direct path can be considered unusable, and takes into account the effect of the possible erroneously detected and transmitted data at the best relay. We first derive the exact statistics of each hop, in terms of probability density function (PDF). Then, the PDFs are used to determine accurate closed form expressions for end-to-end bit-error rate (BER) of binary phase-shift keying (BPSK) modulation where the detector may use maximum ration combining (MRC) or selection combining (SC). Finally, we validate our analysis by showing that performance simulation results coincide with our analytical results over linear network (LN) architecture and considering Rayleigh fading channels. © 2011 IEEE.

  10. Numerical analysis of performance of steam reformer of methane reforming hydrogen production system connected with high-temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Yin Huaqiang; Jiang Shengyao; Zhang Youjie

    2007-01-01

    Methane conversion rate and hydrogen output are important performance indexes of the steam reformer. The paper presents numerical analysis of performance of the reformer connected with high-temperature gas-cooled reactor HTR-10. Setting helium inlet flow rate fixed, performance of the reformer was examined with different helium inlet temperature, pressure, different process gas temperature, pressure, flow rate, and different steam to carbon ratio. As the range concerned, helium inlet temperature has remarkable influence on the performance, and helium inlet temperature, process gas temperature and pressure have little influence on the performance, and improving process gas flow rate, methane conversion rate decreases and hydrogen output increases, however improving steam to carbon ratio has reverse influence on the performance. (authors)

  11. Development of high performance liquid chromatography method for miconazole analysis in powder sample

    Science.gov (United States)

    Hermawan, D.; Suwandri; Sulaeman, U.; Istiqomah, A.; Aboul-Enein, H. Y.

    2017-02-01

    A simple high performance liquid chromatography (HPLC) method has been developed in this study for the analysis of miconazole, an antifungal drug, in powder sample. The optimized HPLC system using C8 column was achieved using mobile phase composition containing methanol:water (85:15, v/v), a flow rate of 0.8 mL/min, and UV detection at 220 nm. The calibration graph was linear in the range from 10 to 50 mg/L with r 2 of 0.9983. The limit of detection (LOD) and limit of quantitation (LOQ) obtained were 2.24 mg/L and 7.47 mg/L, respectively. The present HPLC method is applicable for the determination of miconazole in the powder sample with a recovery of 101.28 % (RSD = 0.96%, n = 3). The developed HPLC method provides short analysis time, high reproducibility and high sensitivity.

  12. Analysis of Operating Performance and Three Dimensional Magnetic Field of High Voltage Induction Motors with Stator Chute

    Directory of Open Access Journals (Sweden)

    WANG Qing-shan

    2017-06-01

    Full Text Available In view of the difficulties on technology of rotor chute in high voltage induction motor,the desig method adopted stator chute structure is put forward. The mathematical model of three dimensional nonlinear transient field for solving stator chute in high voltage induction motor is set up. Through the three dimensional entity model of motor,three dimensional finite element method based on T,ψ - ψ electromagnetic potential is adopted for the analysis and calculation of stator chute in high voltage induction motor under rated condition. The distributions long axial of fundamental wave magnetic field and tooth harmonic wave magnetic field are analyzed after stator chute,and the weakening effects on main tooth harmonic magnetic field are researched. Further more,the comparison analysis of main performance parameters of chute and straight slot is carried out under rated condition. The results show that the electrical performance of stator chute is better than that of straight slot in high voltage induction motor,and the tooth harmonic has been sharply decreased

  13. Performance Analysis of High-Speed Deep/Shallow Recessed Hybrid Bearing

    Directory of Open Access Journals (Sweden)

    Lei Wang

    2013-01-01

    Full Text Available The present paper proposes a theoretical analysis of the performance of deep/shallow recessed hybrid bearing. It is intended that, on the basis of the numerical results drawn from this study, appropriate shallow recess depth and width can be determined for use in the bearing design process. By adopting bulk flow theory, the turbulent Reynolds equation and energy equation are modified and solved numerically including concentrated inertia effects at the recess edge with different depth and width of shallow recess. The results indicate that the load capacity, drag torque increases as the depth of shallow recess is shallower and the width ratio (half angle of deep recess versus half angle of shallow recess is smaller. In contrast, the flow rate decreases as the depth of shallow recess is shallower and the width ratio is smaller. Nevertheless, the appropriate design of the depth and width of shallow recess might well induce the performance of high-speed deep/shallow recessed hybrid bearing.

  14. Postal auditing methodology used to find out the performance of high rate brachytherapy equipment

    International Nuclear Information System (INIS)

    Morales, J.A.; Campa, R.

    1998-01-01

    This work describes results from a methodology implemented at the Secondary Laboratory for Dosimetric Calibration at CPHR used to check the brachytherapy performance at high doses rate using Cesium 137 or cobalt 60 sources

  15. High Strain Rate Characterisation of Composite Materials

    DEFF Research Database (Denmark)

    Eriksen, Rasmus Normann Wilken

    -reinforced polymers, were considered, and it was first shown that the loading history controls equilibrium process. Then the High-speed servo-hydraulic test machine was analysed in terms its ability to create a state of constant strain rate in the specimen. The invertible inertial forces in the load train prevented...... from designing and constructing a high-speed servo-hydraulic test machine and by performing a comprehensive test series. The difficulties encountered in the test work could be addressed with the developed analysis. The conclusion was that the High-speed servo-hydraulic test machine is less suited...... for testing fibre-reinforced polymers due to their elastic behaviour and low strain to failure. This is problematic as the High-speed servo-hydraulic test machine closes the gap between quasi-static tests rates and lower strain rates, which are achievable with the Split Hopkinson Pressure Bar. The Split...

  16. Brachytherapy for cervix cancer: low-dose rate or high-dose rate brachytherapy – a meta-analysis of clinical trials

    Directory of Open Access Journals (Sweden)

    Stefano Eduardo J

    2009-04-01

    Full Text Available Abstract Background The literature supporting high-dose rate brachytherapy (HDR in the treatment of cervical carcinoma derives primarily from retrospective series. However, controversy still persists regarding the efficacy and safety of HDR brachytherapy compared to low-dose rate (LDR brachytherapy, in particular, due to inadequate tumor coverage for stage III patients. Whether LDR or HDR brachytherapy produces better results for these patients in terms of survival rate, local control rate and the treatment complications remain controversial. Methods A meta-analysis of RCT was performed comparing LDR to HDR brachytherapy for cervix cancer treated for radiotherapy alone. The MEDLINE, EMBASE, CANCERLIT and Cochrane Library databases, as well as abstracts published in the annual proceedings were systematically searched. We assessed methodological quality for each outcome by grading the quality of evidence using the Grading of Recommendations Assessment, Development and Evaluation (GRADE methodology. We used "recommend" for strong recommendations, and "suggest" for weak recommendations. Results Pooled results from five randomized trials (2,065 patients of HDR brachytherapy in cervix cancer showed no significant increase of mortality (p = 0.52, local recurrence (p = 0.68, or late complications (rectal; p = 0.7, bladder; p = 0.95 or small intestine; p = 0.06 rates as compared to LDR brachytherapy. In the subgroup analysis no difference was observed for overall mortality and local recurrence in patients with clinical stages I, II and III. The quality of evidence was low for mortality and local recurrence in patients with clinical stage I, and moderate for other clinical stages. Conclusion Our meta-analysis shows that there are no differences between HDR and LDR for overall survival, local recurrence and late complications for clinical stages I, II and III. By means of the GRADE system, we recommend the use of HDR for all clinical stages of cervix

  17. Brachytherapy for cervix cancer: low-dose rate or high-dose rate brachytherapy – a meta-analysis of clinical trials

    Science.gov (United States)

    Viani, Gustavo A; Manta, Gustavo B; Stefano, Eduardo J; de Fendi, Ligia I

    2009-01-01

    Background The literature supporting high-dose rate brachytherapy (HDR) in the treatment of cervical carcinoma derives primarily from retrospective series. However, controversy still persists regarding the efficacy and safety of HDR brachytherapy compared to low-dose rate (LDR) brachytherapy, in particular, due to inadequate tumor coverage for stage III patients. Whether LDR or HDR brachytherapy produces better results for these patients in terms of survival rate, local control rate and the treatment complications remain controversial. Methods A meta-analysis of RCT was performed comparing LDR to HDR brachytherapy for cervix cancer treated for radiotherapy alone. The MEDLINE, EMBASE, CANCERLIT and Cochrane Library databases, as well as abstracts published in the annual proceedings were systematically searched. We assessed methodological quality for each outcome by grading the quality of evidence using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology. We used "recommend" for strong recommendations, and "suggest" for weak recommendations. Results Pooled results from five randomized trials (2,065 patients) of HDR brachytherapy in cervix cancer showed no significant increase of mortality (p = 0.52), local recurrence (p = 0.68), or late complications (rectal; p = 0.7, bladder; p = 0.95 or small intestine; p = 0.06) rates as compared to LDR brachytherapy. In the subgroup analysis no difference was observed for overall mortality and local recurrence in patients with clinical stages I, II and III. The quality of evidence was low for mortality and local recurrence in patients with clinical stage I, and moderate for other clinical stages. Conclusion Our meta-analysis shows that there are no differences between HDR and LDR for overall survival, local recurrence and late complications for clinical stages I, II and III. By means of the GRADE system, we recommend the use of HDR for all clinical stages of cervix cancer. PMID:19344527

  18. High rate gamma spectroscopy system for activation analysis of short-lived isomeric transitions

    Energy Technology Data Exchange (ETDEWEB)

    Westphall, G P [Atominstitut der Oesterreichischen Hochschulen, Vienna

    1976-07-15

    A high rate spectroscopy system specially suited for measurement of short-lived isomeric transitions is described, which, as part of a fast activation analysis facility at the TRIGA Mark II reactor, provides for automatic recording and immediate evaluation of gamma spectra taken from nuclides activated at stationary or pulsed reactor power. The system consists of a commercial de-coupled Ge(Li)-detector of 70 cm/sup 3/ modified for recycling operation for input rates in excess of 500000 c/s /sup 60/Co, a time variant trapezoidal shaping section and a fast constant dead-time ADC coupled to a programmed multichannel analyzer. Novel circuits for efficient pile-up rejection and time variant base line restoration extend the concept of gated integration up to count rates of more than 200000 c/s /sup 60/Co. Time-sequenced recording of spectra is performed by a minicomputer operated as a front-end processor of a larger laboratory computer, where final data processing takes place. New concepts for very simple and cost-effective implementation of multichannel analyzers by means of general purpose small computers are described.

  19. Validation of Heart Rate Monitor Polar RS800 for Heart Rate Variability Analysis During Exercise.

    Science.gov (United States)

    Hernando, David; Garatachea, Nuria; Almeida, Rute; Casajús, Jose A; Bailón, Raquel

    2018-03-01

    Hernando, D, Garatachea, N, Almeida, R, Casajús, JA, and Bailón, R. Validation of heart rate monitor Polar RS800 for heart rate variability analysis during exercise. J Strength Cond Res 32(3): 716-725, 2018-Heart rate variability (HRV) analysis during exercise is an interesting noninvasive tool to measure the cardiovascular response to the stress of exercise. Wearable heart rate monitors are a comfortable option to measure interbeat (RR) intervals while doing physical activities. It is necessary to evaluate the agreement between HRV parameters derived from the RR series recorded by wearable devices and those derived from an electrocardiogram (ECG) during dynamic exercise of low to high intensity. Twenty-three male volunteers performed an exercise stress test on a cycle ergometer. Subjects wore a Polar RS800 device, whereas ECG was also recorded simultaneously to extract the reference RR intervals. A time-frequency spectral analysis was performed to extract the instantaneous mean heart rate (HRM), and the power of low-frequency (PLF) and high-frequency (PHF) components, the latter centered on the respiratory frequency. Analysis was done in intervals of different exercise intensity based on oxygen consumption. Linear correlation, reliability, and agreement were computed in each interval. The agreement between the RR series obtained from the Polar device and from the ECG is high throughout the whole test although the shorter the RR is, the more differences there are. Both methods are interchangeable when analyzing HRV at rest. At high exercise intensity, HRM and PLF still presented a high correlation (ρ > 0.8) and excellent reliability and agreement indices (above 0.9). However, the PHF measurements from the Polar showed reliability and agreement coefficients around 0.5 or lower when the level of the exercise increases (for levels of O2 above 60%).

  20. A Performance Evaluation of a Notebook PC under a High Dose-Rate Gamma Ray Irradiation Test

    Directory of Open Access Journals (Sweden)

    Jai Wan Cho

    2014-01-01

    Full Text Available We describe the performance of a notebook PC under a high dose-rate gamma ray irradiation test. A notebook PC, which is small and light weight, is generally used as the control unit of a robot system and loaded onto the robot body. Using TEPCO’s CAMS (containment atmospheric monitoring system data, the gamma ray dose rate before and after a hydrogen explosion in reactor units 1–3 of the Fukushima nuclear power plant was more than 150 Gy/h. To use a notebook PC as the control unit of a robot system entering a reactor building to mitigate the severe accident situation of a nuclear power plant, the performance of the notebook PC under such intense gamma-irradiation fields should be evaluated. Under a similar dose-rate (150 Gy/h gamma ray environment, the performances of different notebook PCs were evaluated. In addition, a simple method for a performance evaluation of a notebook PC under a high dose-rate gamma ray irradiation test is proposed. Three notebook PCs were tested to verify the method proposed in this paper.

  1. Improvements in the energy resolution and high-count-rate performance of bismuth germanate

    International Nuclear Information System (INIS)

    Koehler, P.E.; Wender, S.A.; Kapustinsky, J.S.

    1985-01-01

    Several methods for improving the energy resolution of bismuth germanate (BGO) have been investigated. It is shown that some of these methods resulted in a substantial improvement in the energy resolution. In addition, a method to improve the performance of BGO at high counting rates has been systematically studied. The results of this study are presented and discussed

  2. Understanding High Rate Behavior Through Low Rate Analog

    Science.gov (United States)

    2014-04-28

    challenges in high rate character- isation of polymers. The most important is that, owing to their low stress wavespeed, the structural response of...box’ tool, to provide supporting date for the rate dependent mechanical character- isation . Experiments were performed on a TA instruments Q800

  3. Investigation of high-rate lithium-thionyl chloride cells

    Science.gov (United States)

    Hayes, Catherine A.; Gust, Steven; Farrington, Michael D.; Lockwood, Judith A.; Donaldson, George J.

    Chemical analysis of a commercially produced high-rate D-size lithium-thionyl cell was carried out, as a function of rate of discharge (1 ohm and 5 ohms), depth of discharge, and temperature (25 C and -40 C), using specially developed methods for identifying suspected minor cell products or impurities which may effect cell performance. These methods include a product-retrieval system which involves solvent extraction to enhance the recovery of suspected semivolatile minor chemicals, and methods of quantitative GC analysis of volatile and semivolatile products. The nonvolatile products were analyzed by wet chemical methods. The results of the analyses indicate that the predominant discharge reaction in this cell is 4Li + 2SOCl2 going to 4LiCl + S + SO2, with SO2 formation decreasing towards the end of cell life (7 to 12 Ah). The rate of discharge had no effect on the product distribution. Upon discharge of the high-rate cell at -40 C, one cell exploded, and all others exhibited overheating and rapid internal pressure rise when allowed to warm up to room temperature.

  4. High rate performance of the carbon encapsulated Li4Ti5O12 for lithium ion battery

    Directory of Open Access Journals (Sweden)

    Qi Cheng

    Full Text Available Li4Ti5O12 (LTO is attractive alternative anode material with excellent cyclic performance and high rate after coating modifications of the conductive materials. Anatase TiO2 and glucose were applied of the synthesis of the carbon coated LTO (C@LTO. XRD results showed that all the major diffractions from the spinel structure of LTO can be found in the C@LTO such as (111, (311, (400 but there are no observations of the Carbon diffraction peaks. Electrochemical Impedance Spectroscopy (EIS data shows C@LTO resistance was nearly half of the LTO value. Rate performance showed that capacity of C@LTO was higher than that of the pure LTO from 0.1 C, 0.2 C, 1 C, 2 C, 5 C and 10 C, which indicates that this is a promising approach to prepare the high performance LTO anode. Keywords: Li-ion batteries, Rate performance, Carbon materials, Li4Ti5O12 anode

  5. Stochastic interest rates in the analysis of energy investments: Implications on economic performance and sustainability

    International Nuclear Information System (INIS)

    Tolis, Athanasios; Tatsiopoulos, Ilias; Doukelis, Aggelos

    2010-01-01

    A systematic impact assessment of stochastic interest and inflation rates on the analysis of energy investments is presented. A real-options algorithm has been created for this task. Constant interest rates incorporating high risk premium have been extensively used for economic calculations, within the framework of traditional direct cash flow methods, thus favouring immediate, irreversible investments in the expense of, sometimes, insubstantially low anticipated yields. In this article, not only incomes and expenses but also interest and inflation rates are considered stochastically evolving according to specific probabilistic models. The numerical experiments indicated that the stochastic interest rate forecasts fluctuate in such low levels that may signal delayed investment entry in favour of higher expected yields. The implementation of stochastically evolving interest rates in energy investment analysis may have a controversial effect on sustainability. Displacements of inefficient plants may be significantly delayed, thus prolonging high CO 2 emission rates. Under the current CO 2 allowance prices or their medium-term forecasts, this situation may not be improved and flexible policy interventions may be necessitated. (author)

  6. A Meta-Analysis of Adult-Rated Child Personality and Academic Performance in Primary Education

    Science.gov (United States)

    Poropat, Arthur E.

    2014-01-01

    Background: Personality is reliably associated with academic performance, but personality measurement in primary education can be problematic. Young children find it difficult to accurately self-rate personality, and dominant models of adult personality may be inappropriate for children. Aims: This meta-analysis was conducted to determine the…

  7. Failure Analysis of a Modern High Performance Diesel Engine Cylinder Head

    Directory of Open Access Journals (Sweden)

    Bingbin Guo

    2014-05-01

    Full Text Available This paper presents a failure analysis on a modern high performance diesel engine cylinder head made of gray cast iron. Cracks appeared intensively at the intersection of two exhaust passages in the cylinder head. The metallurgical examination was conducted in the crack origin zone and other zones. Meanwhile, the load state of the failure part of the cylinder head was determined through the Finite Element Analysis. The results showed that both the point of the maximum temperature and the point of the maximum thermal-mechanical coupling stress were not in the crack position. The excessive load was not the main cause of the failure. The large cooling rate in the casting process created an abnormal graphite zone that existed below the surface of the exhaust passage (about 1.1 mm depth, which led to the fracture of the cylinder head. In the fractured area, there were a large number of casting defects (dip sand, voids, etc. and inferior graphite structure (type D, type E which caused stress concentration. Moreover, high temperature gas entered the cracks, which caused material corrosion, material oxidization, and crack propagation. Finally, premature fracture of the cylinder head took place.

  8. High-tech industries' overseas investment performance evaluation - Application of data envelopment analysis

    Directory of Open Access Journals (Sweden)

    Ridong Hu

    2013-12-01

    Full Text Available With the rapid change of the social environment, Mainland China has become a new economic market due to the great domestic demand caused by its enormous population and the increasing economic growth rate. Taiwanese businesses have gradually turned to develop in China under the pressure of increasing domestic wages and land costs for expanding factories as well as the enhancement of environmental protection. Mainland China presents the advantages of ample land, low labor costs, monoethnicity, and easy language communication making it an attractive major investment location for Taiwanese high-tech industries. Data Envelopment Analysis (DEA is applied to measure overseas investment efficiency evaluation of Taiwanese high-tech businesses in China, where the Delphi Method is used for selecting the inputs of the number of employees, R&D expenses, and gross sales in total assets. Sensitivity Analysis is further utilized for acquiring the most efficient unit and individual units with operating efficiency. The research results show that 1.Three high-tech businesses that present constant returns to scale perform optimally with overseas investment efficiency 2.Two high-tech companies with decreasing returns to scale appear that they could improve the overseas investment efficiency by decreasing the scale to enhancing the marginal returns, and 3.Sixteen high-tech enterprises reveal increasing returns to scale, showing that they could expand the scale to enhance the marginal returns and further promote efficiency.

  9. Pedalling rate affects endurance performance during high-intensity cycling

    DEFF Research Database (Denmark)

    Nielsen, Jens Steen; Hansen, Ernst Albin; Sjøgaard, Gisela

    2004-01-01

    The purpose of this study into high-intensity cycling was to: (1) test the hypothesis that endurance time is longest at a freely chosen pedalling rate (FCPR), compared to pedalling rates 25% lower (FCPR-25) and higher (FCPR+25) than FCPR, and (2) investigate how physiological variables......, and endurance time at W90 with FCPR-25, FCPR, and FCPR+25. Power reserve was calculated as the difference between applied power output at a given pedalling rate and peak crank power at this same pedalling rate. W90 was 325 (47) W. FCPR at W90 was 78 (11) rpm, resulting in FCPR-25 being 59 (8) rpm and FCPR+25...... time was negatively related to VO(2max), W90 and % MHC I, while positively related to power reserve. In conclusion, at group level, endurance time was longer at FCPR and at a pedalling rate 25% lower compared to a pedalling rate 25% higher than FCPR. Further, inter-individual physiological variables...

  10. Analysis of heating effect on the process of high deposition rate microcrystalline silicon

    International Nuclear Information System (INIS)

    Xiao-Dan, Zhang; He, Zhang; Chang-Chun, Wei; Jian, Sun; Guo-Fu, Hou; Shao-Zhen, Xiong; Xin-Hua, Geng; Ying, Zhao

    2010-01-01

    A possible heating effect on the process of high deposition rate microcrystalline silicon has been studied. It includes the discharge time-accumulating heating effect, discharge power, inter-electrode distance, and total gas flow rate induced heating effect. It is found that the heating effects mentioned above are in some ways quite similar to and in other ways very different from each other. However, all of them will directly or indirectly cause the increase of the substrate surface temperature during the process of depositing microcrystalline silicon thin films, which will affect the properties of the materials with increasing time. This phenomenon is very serious for the high deposition rate of microcrystalline silicon thin films because of the high input power and the relatively small inter-electrode distance needed. Through analysis of the heating effects occurring in the process of depositing microcrystalline silicon, it is proposed that the discharge power and the heating temperature should be as low as possible, and the total gas flow rate and the inter-electrode distance should be suitable so that device-grade high quality deposition rate microcrystalline silicon thin films can be fabricated

  11. High Performance Descriptive Semantic Analysis of Semantic Graph Databases

    Energy Technology Data Exchange (ETDEWEB)

    Joslyn, Cliff A.; Adolf, Robert D.; al-Saffar, Sinan; Feo, John T.; Haglin, David J.; Mackey, Greg E.; Mizell, David W.

    2011-06-02

    As semantic graph database technology grows to address components ranging from extant large triple stores to SPARQL endpoints over SQL-structured relational databases, it will become increasingly important to be able to understand their inherent semantic structure, whether codified in explicit ontologies or not. Our group is researching novel methods for what we call descriptive semantic analysis of RDF triplestores, to serve purposes of analysis, interpretation, visualization, and optimization. But data size and computational complexity makes it increasingly necessary to bring high performance computational resources to bear on this task. Our research group built a novel high performance hybrid system comprising computational capability for semantic graph database processing utilizing the large multi-threaded architecture of the Cray XMT platform, conventional servers, and large data stores. In this paper we describe that architecture and our methods, and present the results of our analyses of basic properties, connected components, namespace interaction, and typed paths such for the Billion Triple Challenge 2010 dataset.

  12. A high rate gamma spectroscopy system for activation analysis of short lived isomeric transitions

    Energy Technology Data Exchange (ETDEWEB)

    Westphal, G P [Atominstitut, Vienna (Austria)

    1976-07-01

    A high rate spectroscopy system specially suited for measurement of short-lived isomeric transitions is described, which, as part of a fast activation analysis facility at the TRIGA Mark II reactor, provides for automatic recording and immediate evaluation of gamma spectra taken from nuclides activated at stationary or pulsed reactor power. The system consists of a commercial DC-coupled Ge(Li)-detector of 70 cm{sup 3} modified for recycling operation for input rates in excess of 500,000 c/s Co-60, a time variant trapezoidal shaping section and a fast constant dead-time ADC coupled to a programmed multi-channel analyzer. Novel circuits for efficient pile-up rejection and time variant base line restoration extend the concept of gated integration up to count rates of more than 300,000 c/s Co-60. Time-sequenced recording of spectra is performed by a mini computer operated as a front-end processor of a larger laboratory computer, where final data processing takes place. New concepts for very simple and cost-effective implementation of multi-channel analyzers by means of general purpose small computers are described. (author)

  13. One-step electrochemically expanded graphite foil for flexible all-solid supercapacitor with high rate performance

    International Nuclear Information System (INIS)

    Li, Han-Yu; Yu, Yao; Liu, Lang; Liu, Lin; Wu, Yue

    2017-01-01

    Flexible solid-state supercapacitors (SSCs) as a candidate for energy storage source, have been attracting intensive attention. Graphene-based materials for SSCs have been widely studied. However, most reported preparation methods for graphene-based materials are energy-consuming, time-consuming and environmentally hazardous, what’s more, the assembling of SSCs need additives, such as current collectors, flexible substrates. So, it is necessary to develop simpler and greener attempts to achieve high-performance, cost-effective, substrates/additives-free and flexible electrodes for SSC devices. Herein, we reported a green and facile one-step process of electrochemical oxidation and expansion in salt solution to activate graphite foil (GF) for fabricating expanded graphite foil (EGF). The EGF electrode with unique structure and high conductivity showed high supercapacitor performance of 65 mF cm −2 , remarkable rate-capability maintaining at a level of 80% even at a current density of 20 mA cm −2 and excellent cycling stability with ∼95% capacitance remaining after 10000 cycles at a current density of 20 mA cm −2 . Moreover, a symmetric flexible all-solid supercapacitor (SSC) device was integrated using EGFs without any current collectors and additives. The flexible EGF-based device showed a high capacitance capacity of 30.5 mF cm −2 , excellent rate performance and good cycle stability which make it holds promise for applications in flexible, portable and wearable electronic devices.

  14. The high performance cluster computing system for BES offline data analysis

    International Nuclear Information System (INIS)

    Sun Yongzhao; Xu Dong; Zhang Shaoqiang; Yang Ting

    2004-01-01

    A high performance cluster computing system (EPCfarm) is introduced, which used for BES offline data analysis. The setup and the characteristics of the hardware and software of EPCfarm are described. The PBS, a queue management package, and the performance of EPCfarm is presented also. (authors)

  15. High-intensity intermittent exercise and its effects on heart rate variability and subsequent strength performance

    Directory of Open Access Journals (Sweden)

    Valéria Leme Gonçalves Panissa

    2016-03-01

    Full Text Available PRUPOSE: To investigate the effects of a 5-km high-intensity interval exercise (HIIE on heart rate variability (HRV and subsequent strength performance. METHODS: nine trained males performed a control session composed of a half-squat strength exercise (4 x 80% of one repetition maximum – 1RM in isolation and 30-min, 1-, 4-, 8- and 24-h after an HIIE (1-min at the velocity peak:1-min passive recovery. All experimental sessions were performed on different days. The maximum number of repetitions and total weight lifted during the strength exercise were registered in all conditions; in addition, prior to each session, HRV were assessed [beat-to-beat intervals (RR and log-transformed of root means square of successive differences in the normal-to-normal intervals (lnRMSSD]. RESULTS: Performance in the strength exercise dropped at 30-min (31% and 1-h (19% post-HIIE concomitantly with lower values of RR (781±79 ms; 799±134 ms, respectively in the same recovery intervals compared to the control (1015±197 ms. Inferential analysis did not detect any effect of condition on lnRMSSD, however, values were lower after 30-min (3.5±0.4 ms and 1-h (3.3±0.5 ms with moderate and large effect sizes (0.9 and 1.2, respectively compared with the control condition (3.9±0.4 ms. CONCLUSION: Both RR and lnRMSSD seem to be associated with deleterious effects on strength performance, although further studies should be conducted to clarify this association.

  16. Performance evaluations of hybrid modulation with different optical labels over PDQ in high bit-rate OLS network systems.

    Science.gov (United States)

    Xu, M; Li, Y; Kang, T Z; Zhang, T S; Ji, J H; Yang, S W

    2016-11-14

    Two orthogonal modulation optical label switching(OLS) schemes, which are based on payload of polarization multiplexing-differential quadrature phase shift keying(POLMUX-DQPSK or PDQ) modulated with identifications of duobinary (DB) label and pulse position modulation(PPM) label, are researched in high bit-rate OLS network. The BER performance of hybrid modulation with payload and label signals are discussed and evaluated in theory and simulation. The theoretical BER expressions of PDQ, PDQ-DB and PDQ-PPM are given with analysis method of hybrid modulation encoding in different the bit-rate ratios of payload and label. Theoretical derivation results are shown that the payload of hybrid modulation has a certain gain of receiver sensitivity than payload without label. The sizes of payload BER gain obtained from hybrid modulation are related to the different types of label. The simulation results are consistent with that of theoretical conclusions. The extinction ratio (ER) conflicting between hybrid encoding of intensity and phase types can be compromised and optimized in OLS system of hybrid modulation. The BER analysis method of hybrid modulation encoding in OLS system can be applied to other n-ary hybrid modulation or combination modulation systems.

  17. Improvement in high-voltage and high rate cycling performance of nickel-rich layered cathode materials via facile chemical vapor deposition with methane

    International Nuclear Information System (INIS)

    Hyuk Son, In; Park, Kwangjin; Hwan Park, Jong

    2017-01-01

    Nickel-rich layered-oxide materials are considered promising candidates for application as cathode material in high-energy lithium ion batteries. However, their cycling performance at high voltages and rate conditions require further improvement for the purpose of commercialization. Here, we report on the facile surface modification of nickel-rich layered oxide by chemical vapor deposition with methane which yields a conductive and protective artificial solid electrolyte interphase layer consisting of amorphous carbon, alkyl lithium carbonate, and lithium carbonate. We examine the mechanism of the protective layer formation and structural deformation of the nickel-rich layered oxide during chemical vapor deposition with methane. Via optimizing the reaction conditions, we improve the electrical conductivity as well as the interfacial stability of the nickel-rich layered oxide without inducing structural deformation. The surface-modified nickel-rich layered oxide exhibits an improved performance due to the resulting enhanced rate capability, high initial efficiency, and long cycle life at high voltage (>4.5 V).

  18. High rate performance of the carbon encapsulated Li4Ti5O12 for lithium ion battery

    Science.gov (United States)

    Cheng, Qi; Tang, Shun; Liang, Jiyuan; Zhao, Jinxing; Lan, Qian; Liu, Chang; Cao, Yuan-Cheng

    Li4Ti5O12 (LTO) is attractive alternative anode material with excellent cyclic performance and high rate after coating modifications of the conductive materials. Anatase TiO2 and glucose were applied of the synthesis of the carbon coated LTO (C@LTO). XRD results showed that all the major diffractions from the spinel structure of LTO can be found in the C@LTO such as (1 1 1), (3 1 1), (4 0 0) but there are no observations of the Carbon diffraction peaks. Electrochemical Impedance Spectroscopy (EIS) data shows C@LTO resistance was nearly half of the LTO value. Rate performance showed that capacity of C@LTO was higher than that of the pure LTO from 0.1 C, 0.2 C, 1 C, 2 C, 5 C and 10 C, which indicates that this is a promising approach to prepare the high performance LTO anode.

  19. Investing in improved performance of national tuberculosis programs reduces the tuberculosis burden: analysis of 22 high-burden countries, 2002-2009.

    Science.gov (United States)

    Akachi, Yoko; Zumla, Alimuddin; Atun, Rifat

    2012-05-15

    To assess the impact of investment in national tuberculosis programs (NTPs) on NTP performance and tuberculosis burden in 22 high-burden countries, as determined by the World Health Organization (WHO). Estimates of annual tuberculosis burden and NTP performance indicators and control variables during 2002-2009 were obtained from the Organization for Economic Cooperation and Development, the WHO, the World Bank, and the Penn World Table for the 22 high-burden countries. Panel data analysis was performed using the outcome variables tuberculosis incidence, prevalence, and mortality and the key explanatory variables Partnership case detection rate and treatment success rate, controlling for gross domestic product per capita, population structure, and human immunodeficiency virus (HIV) prevalence. A $1 per capita (general population) higher NTP budget (including domestic and external sources) was associated with a 1.9% (95% confidence interval, .12%-3.6%) higher estimated case detection rate the following year for the 22 high-burden countries between 2002 and 2009. In the final models, which corrected for autocorrelation and heteroskedasticity, achieving the STOP TB Partnership case detection rate target of >70% was associated with significantly (P < .01) lower tuberculosis incidence, prevalence, and mortality the following year, even when controlling for general economic development and HIV prevalence as potential confounding variables. Increased investment in NTPs was significantly associated with improved performance and with a downward trend in the tuberculosis burden in the 22 high-burden countries during 2002-2009.

  20. Hierarchical N-Rich Carbon Sponge with Excellent Cycling Performance for Lithium-Sulfur Battery at High Rates.

    Science.gov (United States)

    Zhen, Mengmeng; Wang, Juan; Wang, Xin; Wang, Cheng

    2018-04-17

    Lithium-sulfur batteries (LSBs) are receiving extensive attention because of their high theoretical energy density. However, practical applications of LSBs are still hindered by their rapid capacity decay and short cycle life, especially at high rates. Herein, a highly N-doped (≈13.42 at %) hierarchical carbon sponge (HNCS) with strong chemical adsorption for lithium polysulfide is fabricated through a simple sol-gel route followed by carbonization. Upon using the HNCS as the sulfur host material in the cathode and an HNCS-coated separator, the battery delivers an excellent cycling stability with high specific capacities of 424 and 326 mA h g -1 and low capacity fading rates of 0.033 % and 0.030 % per cycle after 1000 cycles under high rates of 5 and 10 C, respectively, which are superior to those of other reported carbonaceous materials. These impressive cycling performances indicate that such a battery could promote the practical application prospects of LSBs. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Biphase Cobalt-Manganese Oxide with High Capacity and Rate Performance for Aqueous Sodium-Ion Electrochemical Energy Storage

    Energy Technology Data Exchange (ETDEWEB)

    Shan, Xiaoqiang [Univ. of New Hampshire, Durham, NH (United States). Dept. of Chemical Engineering; Charles, Daniel S. [Univ. of New Hampshire, Durham, NH (United States). Dept. of Chemical Engineering; Xu, Wenqian [Argonne National Lab. (ANL), Argonne, IL (United States). Advanced Photon Source (APS). X-ray Science Division; Feygenson, Mikhail [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Chemical and Engineering Materials Division and Spallation Neutron Source (SNS) outstation Juelich Centre for Neutron Science (JCNS), Forschungszentrum Juelich GmbH; Su, Dong [Brookhaven National Lab. (BNL), Upton, NY (United States). Center for Functional Nanomaterials (CFN); Teng, Xiaowei [Univ. of New Hampshire, Durham, NH (United States). Dept. of Chemical Engineering

    2017-11-22

    Manganese-based metal oxide electrode materials are of great importance in electrochemical energy storage for their favorable redox behavior, low cost and environmental-friendliness. However, their storage capacity and cycle life in aqueous Na-ion electrolytes is not satisfactory. In this paper, we report the development of a bi-phase cobalt-manganese oxide (Co-Mn-O) nanostructured electrode material, comprised of a layered MnO2.H2O birnessite phase and a (Co0.83Mn0.13Va0.04)tetra(Co0.38Mn1.62)octaO3.72 (Va: vacancy; tetra: tetrahedral sites; octa: octahedral sites) spinel phase, verified by neutron total scattering and pair distribution function analyses. The bi-phase Co-Mn-O material demonstrates an excellent storage capacity towards Na-ions in an aqueous electrolyte (121 mA h g-1 at a scan rate of 1 mV s-1 in the half-cell and 81 mA h g-1 at a current density of 2 A g-1 after 5000 cycles in full-cells), as well as high rate performance (57 mA h g-1 a rate of 360 C). Electro-kinetic analysis and in situ X-ray diffraction measurements further confirm that the synergistic interaction between the spinel and layered phases, as well as the vacancy of the tetrahedral sites of spinel phase, contribute to the improved capacity and rate performance of the Co-Mn-O material by facilitating both diffusion-limited redox and capacitive charge storage processes.

  2. Modeling Phase-transitions Using a High-performance, Isogeometric Analysis Framework

    KAUST Repository

    Vignal, Philippe; Dalcin, Lisandro; Collier, Nathan; Calo, Victor M.

    2014-01-01

    In this paper, we present a high-performance framework for solving partial differential equations using Isogeometric Analysis, called PetIGA, and show how it can be used to solve phase-field problems. We specifically chose the Cahn-Hilliard equation

  3. Effects of Rating Purpose and Rater Self-Esteem on Performance Ratings.

    Science.gov (United States)

    1983-03-01

    examined in a laboratory study, using a 2x2 analysis of variance design. Results indicate that low self - esteem raters assign significantly higher...design. Results indicate that low self - esteem raters assign significantly higher performance ratings when performance appraisal information will be used...studies indicated that individuals low in self - esteem have less self -confidence, feel less competent, and rely more on others’ opinions than do individuals

  4. ANALYSIS OF RELAPSE RATE AND METASTASES OF HIGH DIFFERENTIATED THYROID CANCER

    Directory of Open Access Journals (Sweden)

    E. V. Savenok

    2015-01-01

    Full Text Available  Analysis of rate of relapses and metastases with well-differentiated thyroid cancer was performed for patients in 2009 to 2013. The study involved 189 patients with thyroid cancer including 98 (51.9 % patients suffering from papillary thyroid cancer, 77 (40.7 % patients suffering from follicular thyroid cancer, and 14 (7.4 % patients suffering from medullary thyroid cancer. 2.04 % of the 98 patients suffering from papillary thyroid cancer manifested a relapse, and lymphogenic metastases of cancer were revealed with 1.0 % of patients. With follicular thyroid cancer (n = 77, lymphogenic metastases were registered in 7.8 % of cases, relapses were revealed in 1.3 % of cases. This analysis demonstrated that observation of patients for 5 years revealed a higher percentage of metastases with patients that suffered from follicular thyroid cancer.

  5. 3D interconnected honeycomb-like and high rate performance porous carbons from petroleum asphalt for supercapacitors

    Science.gov (United States)

    Pan, Lei; Li, Xinxin; Wang, Yixian; Liu, Jialiang; Tian, Wei; Ning, Hui; Wu, Mingbo

    2018-06-01

    In this paper, 3D interconnected honeycomb-like hierarchical porous carbons (HPCs) are prepared from petroleum asphalt via in-situ KOH activation in a molten salt medium. As symmetry two electrodes for supercapacitors, HPCs with high specific surface area of 2227 m2 g-1 show high rate performance, i.e. 265 F g-1 at 0.05 A g-1, 221 F g-1 at 20 A g-1, and superior cycle stability with 91.1% capacitance retention at 5 A g-1 after 10,000 cycles in 6 M KOH electrolyte. This facile strategy to prepare massive HPCs from cheap petroleum asphalt can provide high performance electrode materials for energy storage devices.

  6. High performance separation of lanthanides and actinides

    International Nuclear Information System (INIS)

    Sivaraman, N.; Vasudeva Rao, P.R.

    2011-01-01

    The major advantage of High Performance Liquid Chromatography (HPLC) is its ability to provide rapid and high performance separations. It is evident from Van Deemter curve for particle size versus resolution that packing materials with particle sizes less than 2 μm provide better resolution for high speed separations and resolving complex mixtures compared to 5 μm based supports. In the recent past, chromatographic support material using monolith has been studied extensively at our laboratory. Monolith column consists of single piece of porous, rigid material containing mesopores and micropores, which provide fast analyte mass transfer. Monolith support provides significantly higher separation efficiency than particle-packed columns. A clear advantage of monolith is that it could be operated at higher flow rates but with lower back pressure. Higher operating flow rate results in higher column permeability, which drastically reduces analysis time and provides high separation efficiency. The above developed fast separation methods were applied to assay the lanthanides and actinides from the dissolver solutions of nuclear reactor fuels

  7. Performance of high-rate TRD prototypes for the CBM experiment in test beam and simulation

    Energy Technology Data Exchange (ETDEWEB)

    Klein-Boesing, Melanie [Institut fuer Kernphysik, Muenster (Germany)

    2008-07-01

    The goal of the future Compressed Baryonic Matter (CBM) experiment is to explore the QCD phase diagram in the region of high baryon densities not covered by other experiments. Among other detectors, it will employ a Transition Radiation Detector (TRD) for tracking of charged particles and electron identification. To meet the demands for tracking and for electron identification at large particle densities and very high interaction rates, high efficiency TRD prototypes have been developed. These prototypes with double-sided pad plane electrodes based on Multiwire Proportional Chambers (MWPC) have been tested at GSI and implemented in the simulation framework of CBM. Results of the performance in a test beam and in simulations are shown. In addition, we present a study of the performance of CBM for electron identification and dilepton reconstruction with this new detector layout.

  8. Cultural values and performance appraisal: assessing the effects of rater self-construal on performance ratings.

    Science.gov (United States)

    Mishra, Vipanchi; Roch, Sylvia G

    2013-01-01

    Much of the prior research investigating the influence of cultural values on performance ratings has focused either on conducting cross-national comparisons among raters or using cultural level individualism/collectivism scales to measure the effects of cultural values on performance ratings. Recent research has shown that there is considerable within country variation in cultural values, i.e. people in one country can be more individualistic or collectivistic in nature. Taking the latter perspective, the present study used Markus and Kitayama's (1991) conceptualization of independent and interdependent self-construals as measures of individual variations in cultural values to investigate within culture variations in performance ratings. Results suggest that rater self-construal has a significant influence on overall performance evaluations; specifically, raters with a highly interdependent self-construal tend to show a preference for interdependent ratees, whereas raters high on independent self-construal do not show a preference for specific type of ratees when making overall performance evaluations. Although rater self-construal significantly influenced overall performance evaluations, no such effects were observed for specific dimension ratings. Implications of these results for performance appraisal research and practice are discussed.

  9. Strategies of high-performing paramedic educational programs.

    Science.gov (United States)

    Margolis, Gregg S; Romero, Gabriel A; Fernandez, Antonio R; Studnek, Jonathan R

    2009-01-01

    To identify the specific educational strategies used by paramedic educational programs that have attained consistently high success rates on the National Registry of Emergency Medical Technicians (NREMT) examination. NREMT data from 2003-2007 were analyzed to identify consistently high-performing paramedic educational programs. Representatives from 12 programs that have maintained a 75% first-attempt pass rate for at least four of five years and had more than 20 graduates per year were invited to participate in a focus group. Using the nominal group technique (NGT), participants were asked to answer the following question: "What are specific strategies that lead to a successful paramedic educational program?" All 12 emergency medical services (EMS) educational programs meeting the eligibility requirements participated. After completing the seven-step NGT process, 12 strategies were identified as leading to a successful paramedic educational program: 1) achieve and maintain national accreditation; 2) maintain high-level entry requirements and prerequisites; 3) provide students with a clear idea of expectations for student success; 4) establish a philosophy and foster a culture that values continuous review and improvement; 5) create your own examinations, lesson plans, presentations, and course materials using multiple current references; 6) emphasize emergency medical technician (EMT)-Basic concepts throughout the class; 7) use frequent case-based classroom scenarios; 8) expose students to as many prehospital advanced life support (ALS) patient contacts as possible, preferably where they are in charge; 9) create and administer valid examinations that have been through a review process (such as qualitative analysis); 10) provide students with frequent detailed feedback regarding their performance (such as formal examination reviews); 11) incorporate critical thinking and problem solving into all testing; and 12) deploy predictive testing with analysis prior to

  10. High Data Rates for AubieSat-2 A & B, Two CubeSats Performing High Energy Science in the Upper Atmosphere

    Science.gov (United States)

    Sims, William H.

    2015-01-01

    This paper will discuss a proposed CubeSat size (3 Units / 6 Units) telemetry system concept being developed at Marshall Space Flight Center (MSFC) in cooperation with Auburn University. The telemetry system incorporates efficient, high-bandwidth communications by developing flight-ready, low-cost, PROTOFLIGHT software defined radio (SDR) payload for use on CubeSats. The current telemetry system is slightly larger in dimension of footprint than required to fit within a 0.75 Unit CubeSat volume. Extensible and modular communications for CubeSat technologies will provide high data rates for science experiments performed by two CubeSats flying in formation in Low Earth Orbit. The project is a collaboration between the University of Alabama in Huntsville and Auburn University to study high energy phenomena in the upper atmosphere. Higher bandwidth capacity will enable high-volume, low error-rate data transfer to and from the CubeSats, while also providing additional bandwidth and error correction margin to accommodate more complex encryption algorithms and higher user volume.

  11. Market Concentration Rate and Market Performance of China’s Swine Industry

    Institute of Scientific and Technical Information of China (English)

    Jia ZHANG; Yucheng HE

    2016-01-01

    Empirical study on market concentration rate and market performance of China’s Swine Industry indicates that higher market concentration rate brings higher overall performance of swine industry. There exists no obvious causal relation between market concentration rate and market performance,but market performance is highly correlated with market concentration rate. The improvement in performance of swine industry is dependent on further optimization of market concentration rate and other factors.

  12. Solving nonlinear, High-order partial differential equations using a high-performance isogeometric analysis framework

    KAUST Repository

    Cortes, Adriano Mauricio; Vignal, Philippe; Sarmiento, Adel; Garcí a, Daniel O.; Collier, Nathan; Dalcin, Lisandro; Calo, Victor M.

    2014-01-01

    In this paper we present PetIGA, a high-performance implementation of Isogeometric Analysis built on top of PETSc. We show its use in solving nonlinear and time-dependent problems, such as phase-field models, by taking advantage of the high-continuity of the basis functions granted by the isogeometric framework. In this work, we focus on the Cahn-Hilliard equation and the phase-field crystal equation.

  13. [Analysis of microalbuminuria with immunonephelometry and high performance liquid chromatography. Evaluation of new criteria].

    Science.gov (United States)

    Markó, Lajos; Molnár, Gergo Attila; Wagner, Zoltán; Koszegi, Tamás; Matus, Zoltán; Mohás, Márton; Kuzma, Mónika; Szijártó, István András; Wittmann, István

    2008-01-13

    Evaluation study, the rate of microalbuminuria positivity among the immunonephelometrically negative patients decreased to 14.5% by high performance liquid chromatography and the decrease in the number of microalbuminuria positive cases by high performance liquid chromatography could be observed mainly in the diabetic and hypertensive group (49% vs. 7.5%), while slighter decrease could be observed in the non-diabetic hypertensive group (37% vs. 26.5%). Applying the traditional criteria, the strongest predictor was the male gender by the logistic regression analysis. In 28% of microalbuminuria negative patients by immunonephelometry the diagnosis of microalbuminuria can be established using high performance liquid chromatography. Almost in one-third of microalbuminuria negative patients by immunonephelometry the diagnosis of microalbuminuria can be established by high performance liquid chromatography for which diagnosis three constitutive urine examinations are still needed. New criteria determined by the Heart Outcomes Prevention Evaluation study can be used neither in case of diabetic and hypertensive patients, nor in the case of non-diabetic hypertensive patients. The gender as the most important predictor of microalbuminuria cannot be ignored.

  14. Evaluation of a High Resolving Power Time-of-Flight Mass Spectrometer for Drug Analysis in Terms of Resolving Power and Acquisition Rate

    Science.gov (United States)

    Pelander, Anna; Decker, Petra; Baessmann, Carsten; Ojanperä, Ilkka

    2011-02-01

    Liquid chromatography time-of-flight mass spectrometry (LC-TOFMS) is applied increasingly to various fields of small molecule analysis. The moderate resolving power (RP) of standard TOFMS instruments poses a risk of false negative results when complex biological matrices are to be analyzed. In this study, the performance of a high resolving power TOFMS instrument (maXis by Bruker Daltonik, Bremen, Germany) was evaluated for drug analysis. By flow injection analysis of critical drug mixtures, including a total of 17 compounds with nominal masses of 212-415 Da and with mass differences of 8.8-23.5 mDa, RP varied from 34,400 to 51,900 (FWHM). The effect of acquisition rate on RP, mass accuracy, and isotopic pattern fit was studied by applying 1, 2, 5, 10, and 20 Hz acquisition rates in a 16 min gradient elution LC separation. All three variables were independent of the acquisition rate, with an average mass accuracy and isotopic pattern fit factor (mSigma) of 0.33 ppm and 5.9, respectively. The average relative standard deviation of RP was 1.8%, showing high repeatability. The performance was tested further with authentic urine extracts containing a co-eluting compound pair with a nominal mass of 296 Da and an 11.2 mDa mass difference. The authentic sample components were readily resolved and correctly identified by the automated data analysis. The average RP, mass accuracy, and isotopic pattern fit were 36,600, 0.9 ppm, and 7.3 mSigma, respectively.

  15. Effects of Excerpt Tempo and Duration on Musicians' Ratings of High-Level Piano Performances

    Science.gov (United States)

    Wapnick, Joel; Ryan, Charlene; Campbell, Louise; Deek, Patricia; Lemire, Renata; Darrow, Alice-Ann

    2005-01-01

    The purpose of this study was to determine how judgments of solo performances recorded at an international piano competition might be affected by excerpt duration (20 versus 60 seconds) and tempo (slow versus fast). Musicians rated performances on six test items. Results indicated that piano majors rated slow excerpts higher than they rated fast…

  16. Three-Dimensional Tubular MoS2/PANI Hybrid Electrode for High Rate Performance Supercapacitor.

    Science.gov (United States)

    Ren, Lijun; Zhang, Gaini; Yan, Zhe; Kang, Liping; Xu, Hua; Shi, Feng; Lei, Zhibin; Liu, Zong-Huai

    2015-12-30

    By using three-dimensional (3D) tubular molybdenum disulfide (MoS2) as both an active material in electrochemical reaction and a framework to provide more paths for insertion and extraction of ions, PANI nanowire arrays with a diameter of 10-20 nm can be controllably grown on both the external and internal surface of 3D tubular MoS2 by in situ oxidative polymerization of aniline monomers and 3D tubular MoS2/PANI hybrid materials with different amounts of PANI are prepared. A controllable growth of PANI nanowire arrays on the tubular MoS2 surface provides an opportunity to optimize the capacitive performance of the obtained electrodes. When the loading amount of PANI is 60%, the obtained MoS2/PANI-60 hybrid electrode not only shows a high specific capacitance of 552 F/g at a current density of 0.5 A/g, but also gives excellent rate capability of 82% from 0.5 to 30 A/g. The remarkable rate performance can be mainly attributed to the architecture with synergistic effect between 3D tubular MoS2 and PANI nanowire arrays. Moreover, the MoS2/PANI-60 based symmetric supercapacitor also exhibits the excellent rate performance and good cycling stability. The specific capacitance based on the total mass of the two electrodes is 124 F/g at a current density of 1 A/g and 79% of its initial capacitance is remained after 6000 cycles. The 3D tubular structure provides a good and favorable method for improving the capacitance retention of PANI electrode.

  17. 3D Networked Tin Oxide/Graphene Aerogel with a Hierarchically Porous Architecture for High-Rate Performance Sodium-Ion Batteries.

    Science.gov (United States)

    Xie, Xiuqiang; Chen, Shuangqiang; Sun, Bing; Wang, Chengyin; Wang, Guoxiu

    2015-09-07

    Low-cost and sustainable sodium-ion batteries are regarded as a promising technology for large-scale energy storage and conversion. The development of high-rate anode materials is highly desirable for sodium-ion batteries. The optimization of mass transport and electron transfer is crucial in the discovery of electrode materials with good high-rate performances. Herein, we report the synthesis of 3 D interconnected SnO2 /graphene aerogels with a hierarchically porous structure as anode materials for sodium-ion batteries. The unique 3 D architecture was prepared by a facile in situ process, during which cross-linked 3 D conductive graphene networks with macro-/meso-sized hierarchical pores were formed and SnO2 nanoparticles were dispersed uniformly on the graphene surface simultaneously. Such a 3 D functional architecture not only facilitates the electrode-electrolyte interaction but also provides an efficient electron pathway within the graphene networks. When applied as anode materials in sodium-ion batteries, the as-prepared SnO2 /graphene aerogel exhibited high reversible capacity, improved cycling performance compared to SnO2 , and promising high-rate capability. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Analysis of Fluconazole in Human Urine Sample by High Performance Liquid Chromatography Method

    International Nuclear Information System (INIS)

    Hermawan, D; Ali, N A Md; Ibrahim, W A Wan; Sanagi, M M

    2013-01-01

    A method for determination of fluconazole, antifungal drug in human urine by using reversed-phased high performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detector was developed. Optimization HPLC conditions were carried out by changing the flow rate and composition of mobile phase. The optimum separation conditions at a flow rate 0.85 mL/min with a composition of mobile phase containing methanol:water (70:30, v/v) with UV detection at a wavelength 254 nm was able to analyze fluconazole within 3 min. The excellent linearity was obtained in the range of concentration 1 to 10 μg/mL with r 2 = 0.998. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.39 μg/mL and 1.28 μg/mL, respectively. Solid phase extraction (SPE) method using octadecylsilane (C18) as a sorbent was used to clean-up and pre-concentrated of the urine sample prior to HPLC analysis. The average recoveries of fluconazole in spiked urine sample was 72.4% with RSD of 3.21% (n=3).

  19. As-grown vertically aligned amorphous TiO2 nanotube arrays as high-rate Li-based micro-battery anodes with improved long-term performance

    International Nuclear Information System (INIS)

    Lamberti, Andrea; Garino, Nadia; Sacco, Adriano; Bianco, Stefano; Chiodoni, Angelica; Gerbaldi, Claudio

    2015-01-01

    Highlights: • Amorphous TiO 2 nanotube (NT) arrays are fabricated by fast and facile anodic oxidation. • Near-theoretical initial specific capacity and remarkable rate capability. • Very long-term cycling stability (>2000 cycles) at a very high C-rate. • High surface area and improved interfacial characteristics for fast diffusion kinetics. • NTs show promising prospects in storage devices conceived for high power applications. - Abstract: Vertically oriented arrays of high surface area TiO 2 nanotubes (NTs) are fabricated by the fast and facile anodic oxidation of a titanium foil. The formation of well-defined one-dimensional nanotubular carpets is assessed by means of morphological Field Emission Scanning Electron Microscopy characterisation, while X-ray diffraction analysis and Transmission Electron Microscopy imaging confirm the amorphous nature of the samples. The electrochemical response evaluated in lab-scale lithium cells is highly satisfying with near-theoretical initial specific capacity and remarkable rate capability, noteworthy in the absence of binders and conductive agents, which would affect the overall energy density. A specific capacity exceeding 200 mAh g −1 is observed at very high 24 C and approx. 80 mAh g −1 are retained even at very high 96 C rate, thus accounting for the promising prospects in storage devices conceived for high power applications. Moreover, the NTs can perform with good cycling stability and capacity retention approaching 50% of the initial value after very long-term operation along with improved durability (> 2000 cycles)

  20. Retrospective analysis of dose delivery in intra-operative high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Oh, M.; Avadhani, J.S.; Malhotra, H.K.; Cunningham, B.; Tripp, P.; Jaggernauth, W.; Podgorsak, M.B.

    2007-01-01

    Background. This study was performed to quantify the inaccuracy in clinical dose delivery due to the incomplete scatter conditions inherent in intra-operative high dose rate (IOHDR) brachytherapy. Methods. Treatment plans of 10 patients previously treated in our facility, which had irregular shapes of treated areas, were used. Treatment geometries reflecting each clinical case were simulated using a phantom assembly with no added build-up on top of the applicator. The treatment planning geometry (full scatter surrounding the applicator) was subsequently simulated for each case by adding bolus on top of the applicator. Results. For geometries representing the clinical IOHDR incomplete scatter environment, measured doses at the 5 mm and 10 mm prescription depths were lower than the corresponding prescribed doses by about 7.7% and 11.1%, respectively. Also, for the two prescription methods, an analysis of the measured dose distributions and their corresponding treatment plans showed average decreases of 1.2 mm and 2.2 mm in depth of prescription dose, respectively. Conclusions. Dosimetric calculations with the assumption of an infinite scatter environment around the applicator and target volume have shown to result in dose delivery errors that significantly decrease the prescription depth for IOHDR treatment.(author)

  1. Potentiostatic activation of as-made graphene electrodes for high-rate performance in supercapacitors

    Science.gov (United States)

    Senthilkumar, Krishnan; Jeong, Seok; Lah, Myoung Soo; Sohn, Kee-Sun; Pyo, Myoungho

    2016-10-01

    A thermally expanded graphene oxide (EGO) electrode is electrochemically activated to simultaneously introduce electrolyte-accessible mesopores and oxygen functional groups. The former is produced via O2 evolution and the latter is incorporated by the intermediate hydroxyl radicals generated during the potentiostatic oxidation of H2O in 1 M H2SO4 at 1.2 V (vs. Ag/AgCl). When applied as a supercapacitor, the potentiostatically treated EGO (EGO-PS) shows significant enhancement in an electric-double layer (EDL) process with a noticeable Faradaic reaction and delivers high capacitance at fast charge/discharge (C/D) rates (334 F g-1 at 0.1 A g-1 and 230 F g-1 at 50 A g-1). In contrast to EGO-PS, EGO that is oxidized potentiodynamically (EGO-PD) shows negligible enhancement in EDL currents. EGO that is subjected to successive potential pulses also shows behaviors similar to EGO-PD, which indicates the importance of hydroxyl radical accumulation via a potentiostatic method for simultaneous functionalization and microstructural control of graphenes. The potentiostatic post-treatment presented here is a convenient post-treatment strategy that could be used to readily increase capacitance and simultaneously improve the high-rate performance of carbon-based electrodes.

  2. High-rate lithium thionyl chloride cells

    Science.gov (United States)

    Goebel, F.

    1982-03-01

    A high-rate C cell with disc electrodes was developed to demonstrate current rates which are comparable to other primary systems. The tests performed established the limits of abuse beyond which the cell becomes hazardous. Tests include: impact, shock, and vibration tests; temperature cycling; and salt water immersion of fresh cells.

  3. Disclosure of Individual Surgeon's Performance Rates During Informed Consent

    Science.gov (United States)

    Burger, Ingrid; Schill, Kathryn; Goodman, Steven

    2007-01-01

    Objective: The purpose of the paper is to examine the ethical arguments for and against disclosing surgeon-specific performance rates to patients during informed consent, and to examine the challenges that generating and using performance rates entail. Methods: Ethical, legal, and statistical theory is explored to approach the question of whether, when, and how surgeons should disclosure their personal performance rates to patients. The main ethical question addressed is what type of information surgeons owe their patients during informed consent. This question comprises 3 related, ethically relevant considerations that are explored in detail: 1) Does surgeon-specific performance information enhance patient decision-making? 2) Do patients want this type of information? 3) How do the potential benefits of disclosure balance against the risks? Results: Calculating individual performance measures requires tradeoffs and involves inherent uncertainty. There is a lack of evidence regarding whether patients want this information, whether it facilitates their decision-making for surgery, and how it is best communicated to them. Disclosure of personal performance rates during informed consent has the potential benefits of enhancing patient autonomy, improving patient decision-making, and improving quality of care. The major risks of disclosure include inaccurate and misleading performance rates, avoidance of high-risk cases, unjust damage to surgeon's reputations, and jeopardized patient trust. Conclusion: At this time, we think that, for most conditions, surgical procedures, and outcomes, the accuracy of surgeon- and patient-specific performance rates is illusory, obviating the ethical obligation to communicate them as part of the informed consent process. Nonetheless, the surgical profession has the duty to develop information systems that allow for performance to be evaluated to a high degree of accuracy. In the meantime, patients should be informed of the quantity of

  4. High performance light-colored nitrile-butadiene rubber nanocomposites.

    Science.gov (United States)

    Lei, Yanda; Guo, Baochun; Chen, Feng; Zhu, Lixin; Zhou, Wenyou; Jia, Demin

    2011-12-01

    High mechanical performance nitrile-butadiene rubber (NBR) with light color was fabricated by the method of in situ formation of zinc disorbate (ZDS) or magnesium disorbate (MDS). The in situ formed ZDS and its polymerization via internal mixing was confirmed by X-ray diffaraction. The mechanical properties, ageing resistance, morphology and the dynamic mechanical analysis were fully studied. It was found that with increasing loading of metallic disorbate both the curing rate and the ionic crosslink density was largely increased. The modulus, tensile strength and tear strength were largely increased. With a comparison between internal mixing and opening mixing, the mechanical performance for the former one was obviously better than the latter one. The high performance was ascribed to the finely dispersion nano domains with irregular shape and obscure interfacial structures. Except for the NBR vulcanizate with a high loading of MDS, the others' ageing resistance with incorporation of these two metallic disorbate was found to be good. Dynamic mechanical analysis (DMA) showed that, with increasing loading of metallic disorbate, the highly increased storage modulus above -20 degrees C, the up-shifted glass transition temperature (Tg) and the reduced mechanical loss were ascribed to strengthened interfacial interactions.

  5. Improved high-rate charge/discharge performances of LiFePO{sub 4}/C via V-doping

    Energy Technology Data Exchange (ETDEWEB)

    Sun, C.S.; Zhou, Z.; Xu, Z.G.; Wang, D.G.; Wei, J.P.; Bian, X.K.; Yan, J. [Institute of New Energy Material Chemistry, Nankai University, Tianjin 300071 (China)

    2009-09-05

    V-doped LiFePO{sub 4}/C cathode materials were prepared through a carbothermal reduction route. The microstructure was characterized by X-ray diffraction, X-ray photoelectron spectroscopy and scanning electron microscopy. The electrochemical Li{sup +} intercalation performances of V-doped LiFePO{sub 4}/C were compared with those of undoped one through galvanostatic intermittent titration technique, cyclic voltamperometry, and electrochemical impedance spectrum. V-doped LiFePO{sub 4}/C showed a high discharge capacity of {proportional_to}70 mAh g{sup -1} at the rate of 20 C (3400 mA g{sup -1}) at room temperature. The significantly improved high-rate charge/discharge capacity is attributed to the increase of Li{sup +} ion ''effective'' diffusion capability. (author)

  6. High capacity and high rate capability of nitrogen-doped porous hollow carbon spheres for capacitive deionization

    International Nuclear Information System (INIS)

    Zhao, Shanshan; Yan, Tingting; Wang, Hui; Chen, Guorong; Huang, Lei; Zhang, Jianping; Shi, Liyi; Zhang, Dengsong

    2016-01-01

    Graphical abstract: - Highlights: • The nitrogen-doped porous hollow carbon spheres were prepared. • The obtained materials have a good capacitive deionization performance. • The electrodes show high salt adsorption rate and good regeneration performance. - Abstract: In this work, nitrogen-doped porous hollow carbon spheres (N-PHCS) were well prepared by using polystyrene (PS) spheres as hard templates and dopamine hydrochloride as carbon and nitrogen sources. Field emission scanning electron microscopy (SEM) and transmission electron microscopy (TEM) images demonstrate that the N-PHCS have a uniform, spherical and hollow structure. Nitrogen adsorption–desorption analysis shows that the N-PHCS have a high specific area of 512 m 2 /g. X-ray photoelectron spectroscopy result reveals that the nitrogen doping amount is 2.92%. The hollow and porous structure and effective nitrogen doping can contribute to large accessible surface area, efficient ion transport and good conductivity. In the electrochemical tests, we can conclude that the N-PHCS have a high specific capacitance value, a good stability and low inner resistance. The N-PHCS electrodes present a high salt adsorption capacity of 12.95 mg/g at a cell voltage of 1.4 V with a flow rate of 40 mL/min in a 500 mg/L NaCl aqueous solution. Moreover, the N-PHCS electrodes show high salt adsorption rate and good regeneration performance in the CDI process. With high surface specific area and effective nitrogen doping, the N-PHCS is promising to the CDI and other electrochemical applications.

  7. High capacity and high rate capability of nitrogen-doped porous hollow carbon spheres for capacitive deionization

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Shanshan; Yan, Tingting; Wang, Hui; Chen, Guorong; Huang, Lei; Zhang, Jianping; Shi, Liyi; Zhang, Dengsong, E-mail: dszhang@shu.edu.cn

    2016-04-30

    Graphical abstract: - Highlights: • The nitrogen-doped porous hollow carbon spheres were prepared. • The obtained materials have a good capacitive deionization performance. • The electrodes show high salt adsorption rate and good regeneration performance. - Abstract: In this work, nitrogen-doped porous hollow carbon spheres (N-PHCS) were well prepared by using polystyrene (PS) spheres as hard templates and dopamine hydrochloride as carbon and nitrogen sources. Field emission scanning electron microscopy (SEM) and transmission electron microscopy (TEM) images demonstrate that the N-PHCS have a uniform, spherical and hollow structure. Nitrogen adsorption–desorption analysis shows that the N-PHCS have a high specific area of 512 m{sup 2}/g. X-ray photoelectron spectroscopy result reveals that the nitrogen doping amount is 2.92%. The hollow and porous structure and effective nitrogen doping can contribute to large accessible surface area, efficient ion transport and good conductivity. In the electrochemical tests, we can conclude that the N-PHCS have a high specific capacitance value, a good stability and low inner resistance. The N-PHCS electrodes present a high salt adsorption capacity of 12.95 mg/g at a cell voltage of 1.4 V with a flow rate of 40 mL/min in a 500 mg/L NaCl aqueous solution. Moreover, the N-PHCS electrodes show high salt adsorption rate and good regeneration performance in the CDI process. With high surface specific area and effective nitrogen doping, the N-PHCS is promising to the CDI and other electrochemical applications.

  8. Effects of Selected Variables on Musicians' Ratings of High-Level Piano Performances

    Science.gov (United States)

    Wapnick, Joel; Ryan, Charlene; Lacaille, Nathalie; Darrow, Alice-Ann

    2004-01-01

    The purpose of this study was to ascertain whether judgments of solo performances recorded at a well-known international piano competition would be affected by musical characteristics such as style (classic period versus early 20th-century Russian) and tempo (slow versus fast). Evaluators rated performances on six test items: tone quality, note…

  9. A High-Spin Rate Measurement Method for Projectiles Using a Magnetoresistive Sensor Based on Time-Frequency Domain Analysis.

    Science.gov (United States)

    Shang, Jianyu; Deng, Zhihong; Fu, Mengyin; Wang, Shunting

    2016-06-16

    Traditional artillery guidance can significantly improve the attack accuracy and overall combat efficiency of projectiles, which makes it more adaptable to the information warfare of the future. Obviously, the accurate measurement of artillery spin rate, which has long been regarded as a daunting task, is the basis of precise guidance and control. Magnetoresistive (MR) sensors can be applied to spin rate measurement, especially in the high-spin and high-g projectile launch environment. In this paper, based on the theory of a MR sensor measuring spin rate, the mathematical relationship model between the frequency of MR sensor output and projectile spin rate was established through a fundamental derivation. By analyzing the characteristics of MR sensor output whose frequency varies with time, this paper proposed the Chirp z-Transform (CZT) time-frequency (TF) domain analysis method based on the rolling window of a Blackman window function (BCZT) which can accurately extract the projectile spin rate. To put it into practice, BCZT was applied to measure the spin rate of 155 mm artillery projectile. After extracting the spin rate, the impact that launch rotational angular velocity and aspect angle have on the extraction accuracy of the spin rate was analyzed. Simulation results show that the BCZT TF domain analysis method can effectively and accurately measure the projectile spin rate, especially in a high-spin and high-g projectile launch environment.

  10. Study of the performance of ATLAS muon drift-tube chambers in magntic fields and at high irradiation rates

    Energy Technology Data Exchange (ETDEWEB)

    Valderanis, Chrysostomos

    2012-07-26

    The performance of ATLAS muon drift-tube (MDT) chambers has been studied in detail using high-energy muon beams. The measurements of the drift tube properties in magnetic fields showed that inelastic collisions of the drifting electrons with the CO{sub 2} molecules in the Ar:CO{sub 2} (93:7) gas mixture of the MDT chambers have to be taken into account in the simulation of the drift properties. Such inelastic collisions are now correctly treated by the Garfield simulation programme from version 9 providing an accurate description of the behaviour of the ATLAS muon drift tubes, in particular in the magnetic field. Measurements at the Gamma Irradiation Facility at CERN were performed to study the performance of the MDT chambers in the presence of high {gamma} ray background fluences. The chambers have a spatial resolution better than 40 {mu}m at the nominal background rates expected at the Large Hadron Collider design luminosity of 10{sup 34} cm{sup -2}s{sup -1} and a resolution better than 50 {mu}m for up to five times higher background rates. Efficient muon detection up to background counting rates of 500 kHz per tube corresponding to 35% occupancy was demonstrated.

  11. Dose rate laser simulation tests adequacy: Shadowing and high intensity effects analysis

    International Nuclear Information System (INIS)

    Nikiforov, A.Y.; Skorobogatov, P.K.

    1996-01-01

    The adequacy of laser based simulation of the flash X-ray effects in microcircuits may be corrupted mainly due to laser radiation shadowing by the metallization and the non-linear absorption in a high intensity range. The numerical joint solution of the optical equations and the fundamental system of equations in a two-dimensional approximation were performed to adjust the application range of laser simulation. As a result the equivalent dose rate to laser intensity correspondence was established taking into account the shadowing as well as the high intensity effects. The simulation adequacy was verified in the range up to 4·10 11 rad(Si)/s with the comparative laser test of a specially designed test structure

  12. Electrical Rating of Concentrated Photovoltaic (CPV) Systems: Long-Term Performance Analysis and Comparison to Conventional PV Systems

    KAUST Repository

    Burhan, Muhammad

    2016-02-29

    The dynamic nature of meteorological data and the commercial availability of diverse photovoltaic systems, ranging from single-junction silicon-based PV panels to concentrated photovoltaic (CPV) systems utilizing multi-junction solar cells and a two-axis solar tracker, demand a simple but accurate methodology for energy planners and PV system designers to understand the economic feasibility of photovoltaic or renewable energy systems. In this paper, an electrical rating methodology is proposed that provides a common playing field for planners, consumers and PV manufacturers to evaluate the long-term performance of photovoltaic systems, as long-term electricity rating is deemed to be a quick and accurate method to evaluate economic viability and determine plant sizes and photovoltaic system power production. A long-term performance analysis based on monthly and electrical ratings (in kWh/m2/year) of two developed CPV prototypes, the Cassegrain mini dish and Fresnel lens CPVs with triple-junction solar cells operating under the meteorological conditions of Singapore, is presented in this paper. Performances are compared to other conventional photovoltaic systems.

  13. Hospital Evaluations by Social Media: A Comparative Analysis of Facebook Ratings among Performance Outliers.

    Science.gov (United States)

    Glover, McKinley; Khalilzadeh, Omid; Choy, Garry; Prabhakar, Anand M; Pandharipande, Pari V; Gazelle, G Scott

    2015-10-01

    An increasing number of hospitals and health systems utilize social media to allow users to provide feedback and ratings. The correlation between ratings on social media and more conventional hospital quality metrics remains largely unclear, raising concern that healthcare consumers may make decisions on inaccurate or inappropriate information regarding quality. The purpose of this study was to examine the extent to which hospitals utilize social media and whether user-generated metrics on Facebook(®) correlate with a Hospital Compare(®) metric, specifically 30-day all cause unplanned hospital readmission rates. This was a retrospective cross-sectional study conducted among all U.S. hospitals performing outside the confidence interval for the national average on 30-day hospital readmission rates as reported on Hospital Compare. Participants were 315 hospitals performing better than U.S. national rate on 30-day readmissions and 364 hospitals performing worse than the U.S. national rate. The study analyzed ratings of hospitals on Facebook's five-star rating scale, 30-day readmission rates, and hospital characteristics including beds, teaching status, urban vs. rural location, and ownership type. Hospitals performing better than the national average on 30-day readmissions were more likely to use Facebook than lower-performing hospitals (93.3 % vs. 83.5 %; p Facebook rating was associated with increased odds of the hospital belonging to the low readmission rate group by a factor of 5.0 (CI: 2.6-10.3, p Facebook-related variables. Hospitals with lower rates of 30-day hospital-wide unplanned readmissions have higher ratings on Facebook than hospitals with higher readmission rates. These findings add strength to the concept that aggregate measures of patient satisfaction on social media correlate with more traditionally accepted measures of hospital quality.

  14. High-rate anisotropic ablation and deposition of polytetrafluoroethylene using synchrotron radiation process

    International Nuclear Information System (INIS)

    Inayoshi, Muneto; Ikeda, Masanobu; Hori, Masaru; Goto, Toshio; Hiramatsu, Mineo; Hiraya, Atsunari.

    1995-01-01

    Both anisotropic ablation and thin film formation of polytetrafluoroethylene (PTFE) were successfully demonstrated using synchrotron radiation (SR) irradiation of PTFE, that is, the SR ablation process. Anisotropic ablation by the SR irradiation was performed at an extremely high rate of 3500 μm/min at a PTFE target temperature of 200degC. Moreover, a PTFE thin film was formed at a high rate of 2.6 μm/min using SR ablation of PTFE. The chemical structure of the deposited film was similar to that of the PTFE target as determined from Fourier transform infrared absorption spectroscopy (FT-IR) analysis. (author)

  15. Performance analysis of 60-min to 1-min integration time rain rate conversion models in Malaysia

    Science.gov (United States)

    Ng, Yun-Yann; Singh, Mandeep Singh Jit; Thiruchelvam, Vinesh

    2018-01-01

    Utilizing the frequency band above 10 GHz is in focus nowadays as a result of the fast expansion of radio communication systems in Malaysia. However, rain fade is the critical factor in attenuation of signal propagation for frequencies above 10 GHz. Malaysia is located in a tropical and equatorial region with high rain intensity throughout the year, and this study will review rain distribution and evaluate the performance of 60-min to 1-min integration time rain rate conversion methods for Malaysia. Several conversion methods such as Segal, Chebil & Rahman, Burgeono, Emiliani, Lavergnat and Gole (LG), Simplified Moupfouma, Joo et al., fourth order polynomial fit and logarithmic model have been chosen to evaluate the performance to predict 1-min rain rate for 10 sites in Malaysia. After the completion of this research, the results show that Chebil & Rahman model, Lavergnat & Gole model, Fourth order polynomial fit and Logarithmic model have shown the best performances in 60-min to 1-min rain rate conversion over 10 sites. In conclusion, it is proven that there is no single model which can claim to perform the best across 10 sites. By averaging RMSE and SC-RMSE over 10 sites, Chebil and Rahman model is the best method.

  16. Recommended HPI [High Pressure Injection] rates for the TMI-2 analysis exercise (0 to 300 minutes)

    International Nuclear Information System (INIS)

    Anderson, J.L.

    1987-09-01

    An international analysis exercise has been organized to evaluate the ability of nuclear reactor severe accident computer codes to predict the TMI-2 accident sequence and core damage progression during the first 300 minutes of the accident. A required boundary condition for the analysis exercise is the High Pressure Injection or make-up rates into the primary system during the accident. Recommended injection rates for the first 300 minutes of the accident are presented. Recommendations for several sensitivity studies are also presented. 6 refs., 5 figs., 1 tab

  17. Self-serving bias effects on job analysis ratings.

    Science.gov (United States)

    Cucina, Jeffrey M; Martin, Nicholas R; Vasilopoulos, Nicholas L; Thibodeuax, Henry F

    2012-01-01

    The purpose of this study was to investigate whether worker-oriented job analysis importance ratings were influenced by subject matter experts' (SME) standing (as measured by self-rated performance) on a competency. This type of relationship (whereby SMEs indicate that the traits they have are important for successful job performance) is an example of the self-serving bias (which is widely described in the social cognition literature and rarely described in the industrial/organizational psychology literature). An archival dataset covering 57 clerical and technical occupations with 26,682 participants was used. Support was found for the relationship between self-rated performance and importance ratings. Significant relationships (typically in the .30s) were observed for all 31 competencies that were studied. Controls were taken to account for common method bias and differences in the competencies required for each of the 57 occupations. Past research has demonstrated the effects of the self-serving bias on personality-based job analysis ratings. This study was the first to extend these findings to traditional job analysis, which covers other competencies in addition to personality. In addition, this study is the first to use operational field data instead of laboratory data.

  18. 5 CFR 430.308 - Rating performance.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Rating performance. 430.308 Section 430.308 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Managing Senior Executive Performance § 430.308 Rating performance. (a) Initial summary rating...

  19. An analysis of acute complications and perioperative morbidity from high dose rate brachytherapy in the treatment of gynecological malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Sarkaria, Jann N; Petereit, Daniel G; Kinsella, Timothy J; Buchler, Dolores A

    1995-07-01

    Purpose: To evaluate the acute morbidity and mortality for high dose-rate (HDR) brachytherapy performed in an outpatient setting in the treatment of gynecological malignancies, and to identify possible risk factors for adverse outcomes. Materials and Methods: One hundred seventy-one patients with cervical (n=129) or uterine (n=42) carcinoma with an intact uterus were evaluated and treated from August 1989 through December 1994, with at least part of their therapy delivered with intracavitary HDR {sup 192}Ir radiation. A total of 830 ICR insertions were performed with greater than 95% done on an outpatient basis under heavy intravenous sedation using fentanyl and midazolam. Perioperative morbidity and mortality were recorded for any event occurring within 30 days of the completion of therapy. Anesthesia risk was evaluated retrospectively in all patients based on the American Society of Anesthesiologists' (ASA) Physical Class System. Results: The uterine patients, many treated with radiation alone because of morbid obesity or medical inoperability, had a significantly higher perioperative morbidity and mortality rate as compared to the cervix patient cohort. Thirteen of the 42 (31%) uterine patients and 8 of the 129 (6%) cervix patients required hospitalization within 30 days of treatment completion (p<0.001). Four of these uterine patients (10%) died of medical complications related to therapy or disease progression within 30 days, while 2 of the cervix patients (1.5%) died: one from disease progression and the other due to radiation enteritis (p=0.05). Preliminary analysis suggests that uterine patients with a high anesthesia risk score (ASA>2) experienced greater morbidity and mortality, while the best predictor of complications in the cervix patients was age greater than 70 years. For the entire cohort of patients, no correlation was found between the 30 day morbidity and mortality and the doses of fentanyl and midazolam used or the length of the procedure

  20. Rate-adaptive BCH coding for Slepian-Wolf coding of highly correlated sources

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Salmistraro, Matteo; Larsen, Knud J.

    2012-01-01

    This paper considers using BCH codes for distributed source coding using feedback. The focus is on coding using short block lengths for a binary source, X, having a high correlation between each symbol to be coded and a side information, Y, such that the marginal probability of each symbol, Xi in X......, given Y is highly skewed. In the analysis, noiseless feedback and noiseless communication are assumed. A rate-adaptive BCH code is presented and applied to distributed source coding. Simulation results for a fixed error probability show that rate-adaptive BCH achieves better performance than LDPCA (Low......-Density Parity-Check Accumulate) codes for high correlation between source symbols and the side information....

  1. Why The Rate Of Financing In Islamic Banks Is High? An Analysis Based On Malaysian Case

    Directory of Open Access Journals (Sweden)

    Irfan Syauqi Beik

    2008-01-01

    Full Text Available Islamic banking has grown rapidly and has become fi nancial-nerve centre in today’s world economy, particularly in the last three decades. It has attracted various entrepreneurs and enterprises to get its fi nancing. However, Islamic banks tend to have a higher rate of fi nancing compared to the conventional ones. This less competitiveness encourage the demand for Islamic products may fall leaving the Islamic banks. Good debtors opted for conventional loans since the interest rates paid were relatively lower and the rest (the bad debtors successfully made their way to Islamic banks. Therefore, the nonperforming financing of Islamic banks is high. This paper attempts to analyze factors that determine high rate of fi nancing in Islamic banks, by taking the case of Malaysian Islamic banks. In this paper, the top three of Islamic banks and conventional banks are selected for comparison. It finds that high default premium and overheads per capital contribute signifi cantly to the high fi nancing rate. Hence, the Islamic banks should diversify their assets and implement universal banking concept.Keywords: Islamic bank, rate of fi nancing, NPF (Non-Performing Financing, universal banking system

  2. Metabolic rate and gross efficiency at high work rates in world class and national level sprint skiers.

    Science.gov (United States)

    Sandbakk, Øyvind; Holmberg, Hans-Christer; Leirdal, Stig; Ettema, Gertjan

    2010-06-01

    The present study investigated metabolic rate (MR) and gross efficiency (GE) at moderate and high work rates, and the relationships to gross kinematics and physical characteristics in elite cross-country skiers. Eight world class (WC) and eight national level (NL) male sprint cross-country skiers performed three 5-min stages using the skating G3 technique, whilst roller skiing on a treadmill. GE was calculated by dividing work rate by MR. Work rate was calculated as the sum of power against gravity and frictional rolling forces. MR was calculated using gas exchange and blood lactate values. Gross kinematics, i.e. cycle length (CL) and cycle rate (CR) were measured by video analysis. Furthermore, the skiers were tested for time to exhaustion (TTE), peak oxygen uptake (VO(2peak)), and maximal speed (V(max)) on the treadmill, and maximal strength in the laboratory. Individual performance level in sprint skating was determined by FIS points. WC skiers did not differ in aerobic MR, but showed lower anaerobic MR and higher GE than NL skiers at a given speed (all P higher V(max) and TTE (all P better technique and to technique-specific power.

  3. Static Analysis of High-Performance Fixed Fluid Power Drive with a Single Positive-Displacement Hydraulic Motor

    Directory of Open Access Journals (Sweden)

    O. F. Nikitin

    2015-01-01

    Full Text Available The article deals with the static calculations in designing a high-performance fixed fluid power drive with a single positive-displacement hydraulic motor. Designing is aimed at using a drive that is under development and yet unavailable to find and record the minimum of calculations and maximum of existing hydraulic units that enable clear and unambiguous performance, taking into consideration an available assortment of hydraulic units of hydraulic drives, to have the best efficiency.The specified power (power, moment and kinematics (linear velocity or angular velocity of rotation parameters of the output element of hydraulic motor determine the main output parameters of the hydraulic drive and the useful power of the hydraulic drive under development. The value of the overall efficiency of the hydraulic drive enables us to judge the efficiency of high-performance fixed fluid power drive.The energy analysis of a diagram of the high-performance fixed fluid power drive shows that its high efficiency is achieved when the flow rate of fluid flowing into each cylinder and the magnitude of the feed pump unit (pump are as nearly as possible.The paper considers the ways of determining the geometric parameters of working hydromotors (effective working area or working volume, which allow a selection of the pumping unit parameters. It discusses the ways to improve hydraulic drive efficiency. Using the principle of holding constant conductivity allows us to specify the values of the pressure losses in the hydraulic units used in noncatalog modes. In case of no exact matching between the parameters of existing hydraulic power modes and a proposed characteristics of the pump unit, the nearest to the expected characteristics is taken as a working version.All of the steps allow us to create the high-performance fixed fluid power drive capable of operating at the required power and kinematic parameters with high efficiency.

  4. Design and Performance Investigation for the Optical Combinational Networks at High Data Rate

    Science.gov (United States)

    Tripathi, Devendra Kr.

    2017-05-01

    This article explores performance study for optical combinational designs based on nonlinear characteristics with semiconductor optical amplifier (SOA). Two configurations for optical half-adder with non-return-to-zero modulation pattern altogether with Mach-Zehnder modulator, interferometer at 50-Gbps data rate have been successfully realized. Accordingly, SUM and CARRY outputs have been concurrently executed and verified for their output waveforms. Numerical simulations for variation of data rate and key design parameters have been effectively executed outcome with optimum performance. Investigations depict overall good performance of the design in terms of the extinction factor. It also inferred that all-optical realization based on SOA is competent scheme, as it circumvents costly optoelectronic translation. This could be well supportive to erect larger complex optical combinational circuits.

  5. High-rate supercapacitive performance of GO/r-GO electrodes interfaced with plastic-crystal-based flexible gel polymer electrolyte

    International Nuclear Information System (INIS)

    Suleman, Mohd; Kumar, Yogesh; Hashmi, S.A.

    2015-01-01

    We report the performance of symmetrical electric double layer capacitors (EDLCs) fabricated with graphene oxide (GO) and reduced graphene oxide (r-GO) electrodes, and plastic crystal based flexible gel polymer electrolyte (GPE) film. The GPE, comprising the solution of lithium bis(trifluoromethanesulfonyl) imide (LiTFSI) in a plastic crystal succinonitrile (SN) entrapped in poly (vinylidinefluoride-co-hexafluoropropylene) (PVdF-HFP), shows suitability as separator/electrolyte in EDLCs due to its excellent electrochemical properties including high ionic conductivity (∼1.97 × 10 −3 S cm −1 a 20 °C). The GO and r-GO electrodes exhibit supercapacitive properties with the SN-based GPE as evidenced from electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and galvanostatic charge-discharge analyses. The residual oxygen functionalities associated with GO-electrodes provide additional pseudo-capacitance resulting in higher specific capacitance and specific energy (∼66 F g −1 and 18 Wh kg −1 , respectively) as compared to r-GO electrodes (specific capacitance ∼60 F g −1 and specific energy ∼15.6 Wh kg −1 ). High knee frequency f k (∼38 Hz), low response time ∼τ 0 (∼166.5 ms) and high pulse power P 0 (∼32.9 kW kg −1 ), observed from EIS studies, indicate the high rate capability of GO-electrodes-based EDLCs. About three fold increase in f k and three times decrease in τ 0 indicates a substantially higher rate performance of r-GO-based EDLCs with respect to GO-based cell. The high rate capability of GO/r-GO electrodes in combination with SN-based GPEs is further confirmed from the rectangular CV shapes up to scan rates of 5 V s −1 for GO and 10 V s −1 for r-GO electrodes. The r-GO based EDLC offers higher specific power (∼54.9 kW kg −1 ) as compared to that of GO-based EDLC (∼33.3 kW kg −1 ), as observed from charge-discaharge studies. Both EDLCs show stable capacitive performance up to ∼11000-13500 charge

  6. Core-Shell Columns in High-Performance Liquid Chromatography: Food Analysis Applications

    Science.gov (United States)

    Preti, Raffaella

    2016-01-01

    The increased separation efficiency provided by the new technology of column packed with core-shell particles in high-performance liquid chromatography (HPLC) has resulted in their widespread diffusion in several analytical fields: from pharmaceutical, biological, environmental, and toxicological. The present paper presents their most recent applications in food analysis. Their use has proved to be particularly advantageous for the determination of compounds at trace levels or when a large amount of samples must be analyzed fast using reliable and solvent-saving apparatus. The literature hereby described shows how the outstanding performances provided by core-shell particles column on a traditional HPLC instruments are comparable to those obtained with a costly UHPLC instrumentation, making this novel column a promising key tool in food analysis. PMID:27143972

  7. Joint variable frame rate and length analysis for speech recognition under adverse conditions

    DEFF Research Database (Denmark)

    Tan, Zheng-Hua; Kraljevski, Ivan

    2014-01-01

    This paper presents a method that combines variable frame length and rate analysis for speech recognition in noisy environments, together with an investigation of the effect of different frame lengths on speech recognition performance. The method adopts frame selection using an a posteriori signal......-to-noise (SNR) ratio weighted energy distance and increases the length of the selected frames, according to the number of non-selected preceding frames. It assigns a higher frame rate and a normal frame length to a rapidly changing and high SNR region of a speech signal, and a lower frame rate and an increased...... frame length to a steady or low SNR region. The speech recognition results show that the proposed variable frame rate and length method outperforms fixed frame rate and length analysis, as well as standalone variable frame rate analysis in terms of noise-robustness....

  8. High-rate operant behavior in two mouse strains: a response-bout analysis.

    Science.gov (United States)

    Johnson, Joshua E; Pesek, Erin F; Newland, M Christopher

    2009-06-01

    Operant behavior sometimes occurs in bouts characterized by an initiation rate, within-bout response rate, and bout length. The generality of this structure was tested using high-rate nose-poking in mice. Reinforcement of short interresponse times produced high response rates while a random-interval schedule held reinforcement rates constant. BALB/c mice produced bouts that were more frequent, longer, and contained a higher within-bout rate of responding (nine nose-pokes/s) than did the C57BL/6 mice (five nose-pokes/s). Adding a running wheel decreased total nose-pokes and bout length, and increased bout-initiation rate. Free-feeding reduced nose-poking by decreasing bout-initiation rate. Photoperiod reversal decreased bout-initiation rate but not total nose-poke rate. Despite strain differences in bout structure, both strains responded similarly to the interventions. The three bout measures were correlated with overall rate but not with each other. Log-survival analyses provided independent descriptors of the structure of high-rate responding in these two strains.

  9. High energy density of Li3-xNaxV2(PO4)3/C cathode material with high rate cycling performance for lithium-ion batteries

    Science.gov (United States)

    Zuo, Zong-Lin; Deng, Jian-Qiu; Pan, Jin; Luo, Wen-Bin; Yao, Qing-Rong; Wang, Zhong-Min; Zhou, Huai-Ying; Liu, Hua-Kun

    2017-07-01

    A serials of micro-sized Li3-xNaxV2(PO4)3/C composite has been synthesized by sol-gel method, comprised of numerous primary nanocrystals. This structure can efficiently facilitate lithium-ion transport in secondary aggregated individual particles due to the short diffusion distance among primary nanocrystals, along with a high tap density. With the increasing of Na doping content, the structure evolution occurs in Li3-xNaxV2(PO4)3 from a single-phase structure to a two-phase structure. The appearance of rhombohedral phase can provide a larger free volume of the interstitial space, fastening ionic movement to offer an excellent high rate capability. Furthermore, Na doping can stabilize the rhombohedral structure of the V2(PO4)3 framework, leading to the remarkable cycling stability. Among all the composites, Li2.6Na0.4V2(PO4)3/C presents the best electrochemical performance with a high energy density of 478.8 Wh kg-1, delivering high initial discharge capacities of 121.6, 113.8 and 109.7 mAh g-1 at the rate of 5 C, 10 C and 20 C in a voltage range of 3.0 - 4.3 V, respectively. It also exhibit an excellent high rate cycling performance, with capacity retention of 85.9 %, 81.7 % and 76.5 % after 1000 cycles at the rate of 5 C, 10 C and 20 C in a voltage range of 3.0 - 4.3 V.

  10. Modeling Phase-transitions Using a High-performance, Isogeometric Analysis Framework

    KAUST Repository

    Vignal, Philippe

    2014-06-06

    In this paper, we present a high-performance framework for solving partial differential equations using Isogeometric Analysis, called PetIGA, and show how it can be used to solve phase-field problems. We specifically chose the Cahn-Hilliard equation, and the phase-field crystal equation as test cases. These two models allow us to highlight some of the main advantages that we have access to while using PetIGA for scientific computing.

  11. Analysis of short-chain acids from anaerobic bacteria by high-performance liquid chromatography.

    OpenAIRE

    Guerrant, G O; Lambert, M A; Moss, C W

    1982-01-01

    A standard mixture of 25 short-chain fatty acids was resolved by high-performance liquid chromatography, using an Aminex HPX-87 column. The acids produced in culture media by anaerobic bacteria were analyzed by high-performance liquid chromatography after extraction with ether and reextraction into a small volume of 0.1 N NaOH. The presence of fumaric acid in culture extracts of Peptostreptococcus anaerobius was confirmed by gas chromatography-mass spectrometry analysis of the trapped eluent ...

  12. The effects of finite rate chemical processes on high enthalpy nozzle performance - A comparison between SPARK and SEAGULL

    Science.gov (United States)

    Carpenter, M. H.

    1988-01-01

    The generalized chemistry version of the computer code SPARK is extended to include two higher-order numerical schemes, yielding fourth-order spatial accuracy for the inviscid terms. The new and old formulations are used to study the influences of finite rate chemical processes on nozzle performance. A determination is made of the computationally optimum reaction scheme for use in high-enthalpy nozzles. Finite rate calculations are compared with the frozen and equilibrium limits to assess the validity of each formulation. In addition, the finite rate SPARK results are compared with the constant ratio of specific heats (gamma) SEAGULL code, to determine its accuracy in variable gamma flow situations. Finally, the higher-order SPARK code is used to calculate nozzle flows having species stratification. Flame quenching occurs at low nozzle pressures, while for high pressures, significant burning continues in the nozzle.

  13. High Rate Performance Nanocomposite Electrode of Mesoporous Manganese Dioxide/Silver Nanowires in KI Electrolytes

    Directory of Open Access Journals (Sweden)

    Yanhua Jiang

    2015-10-01

    Full Text Available In recent years, manganese dioxide has become a research hotspot as an electrode material because of its low price. However, it has also become an obstacle to industrialization due to its low ratio of capacitance and the low rate performance which is caused by the poor electrical conductivity. In this study, a KI solution with electrochemical activity was innovatively applied to the electrolyte, and we systematically investigated the rate performance of the mesoporous manganese dioxide and the composite electrode with silver nanowires in supercapacitors. The results showed that when mesoporous manganese dioxide and mesoporous manganese dioxide/silver nanowires composite were used as electrodes, the strength of the current was amplified five times (from 0.1 to 0.5 A/g, the remaining rates of specific capacitance were 95% (from 205.5 down to 197.1 F/g and 92% (from 208.1 down to 191.7 F/g in the KI electrolyte, and the rate performance was much higher than which in an Na2SO4 electrolyte with a remaining rate of 25% (from 200.3 down to 49.1 F/g and 60% (from 187.2 down to 113.1 F/g. The morphology and detail structure were investigated by Scanning electron microscopy, X-ray diffraction, Fourier transform infrared spectrometry and Nitrogen adsorption-desorption isotherms. The electrochemical performance was assessed by cyclic voltammograms, galvanostatic charge/discharge and electrochemical impedance spectroscopy.

  14. Evaluation of Dynamic Deformation Behaviors in Metallic Materials under High Strain-Rates Using Taylor Bar Impact Test

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Kyung Oh; Shin, Hyung Seop [Andong National Univ., Andong (Korea, Republic of)

    2016-09-15

    To ensure the reliability and safety of various mechanical systems in accordance with their high-speed usage, it is necessary to evaluate the dynamic deformation behavior of structural materials under impact load. However, it is not easy to understand the dynamic deformation behavior of the structural materials using experimental methods in the high strain-rate range exceeding 10{sup 4} s{sup -1}. In this study, the Taylor bar impact test was conducted to investigate the dynamic deformation behavior of metallic materials in the high strain-rate region, using a high-speed photography system. Numerical analysis of the Taylor bar impact test was performed using AUTODYN S/W. The results of the analysis were compared with the experimental results, and the material behavior in the high strain-rate region was discussed.

  15. A Study of the Associations between Conditions of Performance and Characteristics of Performers and New York State Solo Performance Ratings

    Science.gov (United States)

    vonWurmb, Elizabeth C.

    2013-01-01

    This dissertation undertakes an analysis of 1,044 performance evaluations from New York State School Music Association (NYSSMA) Spring Festival solo adjudication ratings of student performers from a large suburban school district. It relies on results of evaluations of observed performances, and takes these evaluations as assessments of what the…

  16. Ni foam supported quasi-core-shell structure of ultrathin Ti3C2 nanosheets through electrostatic layer-by-layer self-assembly as high rate-performance electrodes of supercapacitors

    Science.gov (United States)

    Tian, Yapeng; Yang, Chenhui; Que, Wenxiu; He, Yucheng; Liu, Xiaobin; Luo, Yangyang; Yin, Xingtian; Kong, Ling Bing

    2017-11-01

    Supercapacitor, as an important energy storage device, is a critical component for next generation electric power system, due to its high power density and long cycle life. In this study, a novel electrode material with quasi-core-shell structure, consisting of negatively charged few layer Ti3C2 nanosheets (FL-Ti3C2) and positively charged polyethyleneimine as building blocks, has been prepared by using an electrostatic layer-by-layer self-assembly method, with highly conductive Ni foam to be used as the skeleton. The unique quasi-core-shell structured ultrathin Ti3C2 nanosheets provide an excellent electron channel, ion transport channel and large effective contact area, thus leading to a great improvement in electrochemical performance of the material. The specific capacitance of the binder-free FL-Ti3C2@Ni foam electrodes reaches 370 F g-1 at the scan rate of 2 mV s-1 and a specific capacitance of 117 F g-1 is obtained even at the scan rate of 1000 mV s-1 in the electrolyte of Li2SO4, indicating a high rate performance. In addition, this electrode shows a long-term cyclic stability with a loss of only 13.7% after 10,000 circles. Furthermore, quantitative analysis has been conducted to ensure the relationship between the capacitive contribution and the rate performance of the as-fabricated electrode.

  17. SPECTRAL ANALYSIS OF EXCHANGE RATES

    Directory of Open Access Journals (Sweden)

    ALEŠA LOTRIČ DOLINAR

    2013-06-01

    Full Text Available Using spectral analysis is very common in technical areas but rather unusual in economics and finance, where ARIMA and GARCH modeling are much more in use. To show that spectral analysis can be useful in determining hidden periodic components for high-frequency finance data as well, we use the example of foreign exchange rates

  18. High rate spectroscopy for on-line nuclear coal analyzer (Nucoalyzer)

    International Nuclear Information System (INIS)

    McQuaid, J.H.; Brown, D.R.; Gozani, T.; Bozorgmanesh, H.

    1980-01-01

    A high count rate, time-variant Ge(Li) spectrometer has been developed for on-line coal analysis. The analyzer is being fabricated for use in a power generating station. Prompt neutron activation of coal samples is the basis of analysis, with 252 Cf as the source for irradiation. The spectroscopy system allows counting rates up to 150 k counts per second without significant loss in energy resolution or peak shape. The high data throughput allows the coal analyzer to be used for on-line process control. The coal analyzer will be discussed, with emphasis on the high-rate signal processing system. Results of analysis of coal samples will be presented

  19. A High Performance Impedance-based Platform for Evaporation Rate Detection.

    Science.gov (United States)

    Chou, Wei-Lung; Lee, Pee-Yew; Chen, Cheng-You; Lin, Yu-Hsin; Lin, Yung-Sheng

    2016-10-17

    This paper describes the method of a novel impedance-based platform for the detection of the evaporation rate. The model compound hyaluronic acid was employed here for demonstration purposes. Multiple evaporation tests on the model compound as a humectant with various concentrations in solutions were conducted for comparison purposes. A conventional weight loss approach is known as the most straightforward, but time-consuming, measurement technique for evaporation rate detection. Yet, a clear disadvantage is that a large volume of sample is required and multiple sample tests cannot be conducted at the same time. For the first time in literature, an electrical impedance sensing chip is successfully applied to a real-time evaporation investigation in a time sharing, continuous and automatic manner. Moreover, as little as 0.5 ml of test samples is required in this impedance-based apparatus, and a large impedance variation is demonstrated among various dilute solutions. The proposed high-sensitivity and fast-response impedance sensing system is found to outperform a conventional weight loss approach in terms of evaporation rate detection.

  20. Improved method for the determination of the cortisol production rate using high-performance liquid chromatography and liquid scintillation counting

    NARCIS (Netherlands)

    van Ingen, H. E.; Endert, E.

    1988-01-01

    Two new methods for the determination of the cortisol production rate using reversed-phase high-performance liquid chromatography are described. One uses ultraviolet detection at 205 nm, the other on-line post-column derivatization with benzamidine, followed by fluorimetric detection. The specific

  1. Research Activity in Computational Physics utilizing High Performance Computing: Co-authorship Network Analysis

    Science.gov (United States)

    Ahn, Sul-Ah; Jung, Youngim

    2016-10-01

    The research activities of the computational physicists utilizing high performance computing are analyzed by bibliometirc approaches. This study aims at providing the computational physicists utilizing high-performance computing and policy planners with useful bibliometric results for an assessment of research activities. In order to achieve this purpose, we carried out a co-authorship network analysis of journal articles to assess the research activities of researchers for high-performance computational physics as a case study. For this study, we used journal articles of the Scopus database from Elsevier covering the time period of 2004-2013. We extracted the author rank in the physics field utilizing high-performance computing by the number of papers published during ten years from 2004. Finally, we drew the co-authorship network for 45 top-authors and their coauthors, and described some features of the co-authorship network in relation to the author rank. Suggestions for further studies are discussed.

  2. Mood states and motor performance: a study with high performance voleybol athletes

    Directory of Open Access Journals (Sweden)

    Lenamar Fiorese Vieira

    2008-07-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2008v10n1p62 The objective of this research was to investigate the relationship between the sporting performance and mood states of high performance volleyball athletes. Twenty-three adult athletes of both sexes were assessed. The measurement instrument adopted was the POMS questionnaire. Data collection was carried out individually during the state championships. Dada were analyzed using descriptive statistics; the Friedman test for analysis of variance and the Mann-Whitney test for differences between means. The results demonstrated that both teams exhibited the mood state profi le corresponding to the “iceberg” profile. In the male team, vigor remained constant throughout all phases of the competition, while in the female team this element was unstable. The male team’s fatigue began low, during the training phase, with rates that rose as the competition progressed, with statistically significant differences between the fi rst and last matches the team played. In the female team, the confusion factor, which was at a high level during training, reduced progressively throughout the competition, with a difference that was signifi cant to p ≤ 0.05. With relation to performance and mood profi le, the female team exhibited statistically significant differences between the mean vigor and fatigue factors of high and low performance athletes. It is therefore concluded that the mood state profi le is a factor that impacts on the motor performance of these high performance teams.

  3. LHCb: LHCb Muon System Performance at High Luminosity

    CERN Multimedia

    Pinci, D

    2013-01-01

    The LHCb detector was conceived to operate with an average Luminosity of $2 \\times 10^{32}$ cm$^{-2}$ s$^{-1}$. During the last year of LHC run, the whole apparatus has shown to be able to perfectly acquire and manage data produced at a Luminosity as high as $4 \\times 10^{32}$ cm$^{-2}$ s$^{-1}$. In these conditions, all sub-detectors operated at average particle rates higher than the design ones and in particular the Multi-Wire Proportional Chambers equipping the Muon System had to sustain a particle rate as high as 250 kHz/cm$^{2}$. In order to study the possibility of increasing the Luminosity of operation of the whole experiment several tests were performed. The effective beam Luminosity at the interaction point of LHCb was increased in several steps up to $10^{33}$ cm$^{-2}$ s$^{-1}$ and in each step the behavior of all the detectors in the Muon System was recorded. The data analysis has allowed to study the performance of the Muon System as a function of the LHC Luminosity and the results are r...

  4. A Multi-Contact, Low Capacitance HPGe Detector for High Rate Gamma Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Cox, Christopher [XIA LLC, Hayward, CA (United States)

    2014-12-04

    The detection, identification and non-destructive assay of special nuclear materials and nuclear fission by-products are critically important activities in support of nuclear non-proliferation programs. Both national and international nuclear safeguard agencies recognize that current accounting methods for spent nuclear fuel are inadequate from a safeguards perspective. Radiation detection and analysis by gamma-ray spectroscopy is a key tool in this field, but no instrument exists that can deliver the required performance (energy resolution and detection sensitivity) in the presence of very high background count rates encountered in the nuclear safeguards arena. The work of this project addresses this critical need by developing a unique gamma-ray detector based on high purity germanium that has the previously unachievable property of operating in the 1 million counts-per-second range while achieving state-of-the-art energy resolution necessary to identify and analyze the isotopes of interest. The technical approach was to design and fabricate a germanium detector with multiple segmented electrodes coupled to multi-channel high rate spectroscopy electronics. Dividing the germanium detector’s signal electrode into smaller sections offers two advantages; firstly, the energy resolution of the detector is potentially improved, and secondly, the detector is able to operate at higher count rates. The design challenges included the following; determining the optimum electrode configuration to meet the stringent energy resolution and count rate requirements; determining the electronic noise (and therefore energy resolution) of the completed system after multiple signals are recombined; designing the germanium crystal housing and vacuum cryostat; and customizing electronics to perform the signal recombination function in real time. In this phase I work, commercial off-the-shelf electrostatic modeling software was used to develop the segmented germanium crystal geometry

  5. Sensitivity of performance assessment of the engineered barriers to nuances of release rate criteria

    International Nuclear Information System (INIS)

    Oliver, D.L.R.

    1987-01-01

    The United States Nuclear Regulatory Commission (NRC) has established criteria for the long-term performance of proposed high-level waste repositories. As with any regulation, the criteria may be interpreted in several ways. Due to the high capital costs and the emotional political climate associated with any high-level radioactive waste repository, it is important that there be an early consensus regarding interpretations of the criteria, and what assumptions may be used to demonstrate compliance with them. This work uses analytic solutions of mass transport theory to demonstrate how sensitive performance analyses are to various nuances of the NRC release rate criterion for the engineered barriers. The analysis is directed at the proposed repository in basalt at the Hanford site in Washington State

  6. Diversity Performance Analysis on Multiple HAP Networks

    Science.gov (United States)

    Dong, Feihong; Li, Min; Gong, Xiangwu; Li, Hongjun; Gao, Fengyue

    2015-01-01

    One of the main design challenges in wireless sensor networks (WSNs) is achieving a high-data-rate transmission for individual sensor devices. The high altitude platform (HAP) is an important communication relay platform for WSNs and next-generation wireless networks. Multiple-input multiple-output (MIMO) techniques provide the diversity and multiplexing gain, which can improve the network performance effectively. In this paper, a virtual MIMO (V-MIMO) model is proposed by networking multiple HAPs with the concept of multiple assets in view (MAV). In a shadowed Rician fading channel, the diversity performance is investigated. The probability density function (PDF) and cumulative distribution function (CDF) of the received signal-to-noise ratio (SNR) are derived. In addition, the average symbol error rate (ASER) with BPSK and QPSK is given for the V-MIMO model. The system capacity is studied for both perfect channel state information (CSI) and unknown CSI individually. The ergodic capacity with various SNR and Rician factors for different network configurations is also analyzed. The simulation results validate the effectiveness of the performance analysis. It is shown that the performance of the HAPs network in WSNs can be significantly improved by utilizing the MAV to achieve overlapping coverage, with the help of the V-MIMO techniques. PMID:26134102

  7. Diversity Performance Analysis on Multiple HAP Networks

    Directory of Open Access Journals (Sweden)

    Feihong Dong

    2015-06-01

    Full Text Available One of the main design challenges in wireless sensor networks (WSNs is achieving a high-data-rate transmission for individual sensor devices. The high altitude platform (HAP is an important communication relay platform for WSNs and next-generation wireless networks. Multiple-input multiple-output (MIMO techniques provide the diversity and multiplexing gain, which can improve the network performance effectively. In this paper, a virtual MIMO (V-MIMO model is proposed by networking multiple HAPs with the concept of multiple assets in view (MAV. In a shadowed Rician fading channel, the diversity performance is investigated. The probability density function (PDF and cumulative distribution function (CDF of the received signal-to-noise ratio (SNR are derived. In addition, the average symbol error rate (ASER with BPSK and QPSK is given for the V-MIMO model. The system capacity is studied for both perfect channel state information (CSI and unknown CSI individually. The ergodic capacity with various SNR and Rician factors for different network configurations is also analyzed. The simulation results validate the effectiveness of the performance analysis. It is shown that the performance of the HAPs network in WSNs can be significantly improved by utilizing the MAV to achieve overlapping coverage, with the help of the V-MIMO techniques.

  8. Computational Environments and Analysis methods available on the NCI High Performance Computing (HPC) and High Performance Data (HPD) Platform

    Science.gov (United States)

    Evans, B. J. K.; Foster, C.; Minchin, S. A.; Pugh, T.; Lewis, A.; Wyborn, L. A.; Evans, B. J.; Uhlherr, A.

    2014-12-01

    The National Computational Infrastructure (NCI) has established a powerful in-situ computational environment to enable both high performance computing and data-intensive science across a wide spectrum of national environmental data collections - in particular climate, observational data and geoscientific assets. This paper examines 1) the computational environments that supports the modelling and data processing pipelines, 2) the analysis environments and methods to support data analysis, and 3) the progress in addressing harmonisation of the underlying data collections for future transdisciplinary research that enable accurate climate projections. NCI makes available 10+ PB major data collections from both the government and research sectors based on six themes: 1) weather, climate, and earth system science model simulations, 2) marine and earth observations, 3) geosciences, 4) terrestrial ecosystems, 5) water and hydrology, and 6) astronomy, social and biosciences. Collectively they span the lithosphere, crust, biosphere, hydrosphere, troposphere, and stratosphere. The data is largely sourced from NCI's partners (which include the custodians of many of the national scientific records), major research communities, and collaborating overseas organisations. The data is accessible within an integrated HPC-HPD environment - a 1.2 PFlop supercomputer (Raijin), a HPC class 3000 core OpenStack cloud system and several highly connected large scale and high-bandwidth Lustre filesystems. This computational environment supports a catalogue of integrated reusable software and workflows from earth system and ecosystem modelling, weather research, satellite and other observed data processing and analysis. To enable transdisciplinary research on this scale, data needs to be harmonised so that researchers can readily apply techniques and software across the corpus of data available and not be constrained to work within artificial disciplinary boundaries. Future challenges will

  9. Thermal Power Plant Performance Analysis

    CERN Document Server

    2012-01-01

    The analysis of the reliability and availability of power plants is frequently based on simple indexes that do not take into account the criticality of some failures used for availability analysis. This criticality should be evaluated based on concepts of reliability which consider the effect of a component failure on the performance of the entire plant. System reliability analysis tools provide a root-cause analysis leading to the improvement of the plant maintenance plan.   Taking in view that the power plant performance can be evaluated not only based on  thermodynamic related indexes, such as heat-rate, Thermal Power Plant Performance Analysis focuses on the presentation of reliability-based tools used to define performance of complex systems and introduces the basic concepts of reliability, maintainability and risk analysis aiming at their application as tools for power plant performance improvement, including: ·         selection of critical equipment and components, ·         defini...

  10. Fuel-disruption experiments under high-ramp-rate heating conditions

    International Nuclear Information System (INIS)

    Wright, S.A.; Worledge, D.H.; Cano, G.L.; Mast, P.K.; Briscoe, F.

    1983-10-01

    This topical report presents the preliminary results and analysis of the High Ramp Rate fuel-disruption experiment series. These experiments were performed in the Annular Core Research Reactor at Sandia National Laboratories to investigate the timing and mode of fuel disruption during the prompt-burst phase of a loss-of-flow accident. High-speed cinematography was used to observe the timing and mode of the fuel disruption in a stack of five fuel pellets. Of the four experiments discussed, one used fresh mixed-oxide fuel, and three used irradiated mixed-oxide fuel. Analysis of the experiments indicates that in all cases, the observed disruption occurred well before fuel-vapor pressure was high enough to cause the disruption. The disruption appeared as a rapid spray-like expansion and occurred near the onset of fuel melting in the irradiated-fuel experiments and near the time of complete fuel melting in the fresh-fuel experiment. This early occurrence of fuel disruption is significant because it can potentially lower the work-energy release resulting from a prompt-burst disassembly accident

  11. High rate tests of the LHCb RICH Upgrade system

    CERN Multimedia

    Blago, Michele Piero

    2016-01-01

    One of the biggest challenges for the upgrade of the LHCb RICH detectors from 2020 is to readout the photon detectors at the full 40 MHz rate of the LHC proton-proton collisions. A test facility has been setup at CERN with the purpose to investigate the behaviour of the Multi Anode PMTs, which have been proposed for the upgrade, and their readout electronics at high trigger rates. The MaPMTs are illuminated with a monochromatic laser that can be triggered independently of the readout electronics. A first series of tests, including threshold scans, is performed at low trigger rates (20 kHz) for both the readout and the laser with the purpose to characterise the behaviour of the system under test. Then the trigger rate is increased in two separate steps. First the MaPMTs are exposed to high illumination by triggering the pulsed laser at a high (20 MHz) repetition rate while the DAQ is readout at the same low rate as before. In this way the performance of the MaPMTs and the attached electronics can be evaluated ...

  12. Authoritative school climate and high school dropout rates.

    Science.gov (United States)

    Jia, Yuane; Konold, Timothy R; Cornell, Dewey

    2016-06-01

    This study tested the association between school-wide measures of an authoritative school climate and high school dropout rates in a statewide sample of 315 high schools. Regression models at the school level of analysis used teacher and student measures of disciplinary structure, student support, and academic expectations to predict overall high school dropout rates. Analyses controlled for school demographics of school enrollment size, percentage of low-income students, percentage of minority students, and urbanicity. Consistent with authoritative school climate theory, moderation analyses found that when students perceive their teachers as supportive, high academic expectations are associated with lower dropout rates. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  13. Dose analysis on high performance vault storage system of spent nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Kei-ichiro; Maki, Koichi; Shimizu, Masashi; Oda, Masashi; Kumagai, Naoki [Hitachi, Ltd., Power and Industrial Systems R and D Laboratory, Hitachi, Ibaraki (Japan); Hoshikawa, Tadahiro; Oyama, Kenichi; Kanai, Hidetoshi [Hitachi Ltd., Ibaraki (Japan). Hitachi Works

    2000-03-01

    The radiation shielding design for the high performance vault storage system is studied in order to satisfy the design targets at the controlled area and the site boundaries. The additional gamma-ray shields in front of the storage tubes and the shielding structures at the entrance of the ducts are installed. The dose rates at the inlet and the outlet of the ducts are estimated by 3D calculation. And the dose rates at the controlled area and the site boundaries are evaluated taking the effect of the direct radiation and the indirect one (skyshine) into consideration. The dose rates at the controlled area and the site boundaries are about 7x10{sup -7} Sv/h and 3x10{sup -10} Sv/h, respectively. Thus, we have the prospect to satisfy the design targets. (author)

  14. Thermodynamic analysis on optimum performance of scramjet engine at high Mach numbers

    International Nuclear Information System (INIS)

    Zhang, Duo; Yang, Shengbo; Zhang, Silong; Qin, Jiang; Bao, Wen

    2015-01-01

    In order to predict the maximum performance of scramjet engine at flight conditions with high freestream Mach numbers, a thermodynamic model of Brayton cycle was utilized to analyze the effects of inlet pressure ratio, fuel equivalence ratio and the upper limit of gas temperature to the specific thrust and the fuel impulse of the scramjet considering the characteristics of non-isentropic compression in the inlet. The results show that both the inlet efficiency and the temperature limit in the combustor have remarkable effects on the overall engine performances. Different with the ideal Brayton cycles assuming isentropic compression without upper limit of gas temperature, both the maximum specific thrust and the maximum fuel impulse of a scramjet present non-monotonic trends against the fuel equivalence ratio in this study. Considering the empirical design efficiencies of inlet, there is a wide range of fuel equivalence ratios in which the fuel impulses remain at high values. Moreover, the maximum specific thrust can also be achieved with a fuel equivalence ratio near this range. Therefore, it is possible to achieve an overall high performance in a scramjet at high Mach numbers. - Highlights: • Thermodynamic analysis with Brayton cycle on overall performances of scramjet. • The compression loss in the inlet was considered in predicting scram-mode operation. • Non-monotonic trends of engine performances against fuel equivalence ratio.

  15. FRAC (failure rate analysis code): a computer program for analysis of variance of failure rates. An application user's guide

    International Nuclear Information System (INIS)

    Martz, H.F.; Beckman, R.J.; McInteer, C.R.

    1982-03-01

    Probabilistic risk assessments (PRAs) require estimates of the failure rates of various components whose failure modes appear in the event and fault trees used to quantify accident sequences. Several reliability data bases have been designed for use in providing the necessary reliability data to be used in constructing these estimates. In the nuclear industry, the Nuclear Plant Reliability Data System (NPRDS) and the In-Plant Reliability Data System (IRPDS), among others, were designed for this purpose. An important characteristic of such data bases is the selection and identification of numerous factors used to classify each component that is reported and the subsequent failures of each component. However, the presence of such factors often complicates the analysis of reliability data in the sense that it is inappropriate to group (that is, pool) data for those combinations of factors that yield significantly different failure rate values. These types of data can be analyzed by analysis of variance. FRAC (Failure Rate Analysis Code) is a computer code that performs an analysis of variance of failure rates. In addition, FRAC provides failure rate estimates

  16. Transistor reset preamplifier for high-rate high-resolution spectroscopy

    International Nuclear Information System (INIS)

    Landis, D.A.; Cork, C.P.; Madden, N.W.; Goulding, F.S.

    1981-10-01

    Pulsed transistor reset of high resolution charge sensitive preamplifiers used in cooled semiconductor spectrometers can sometimes have an advantage over pulsed light reset systems. Several versions of transistor reset spectrometers using both silicon and germanium detectors have been built. This paper discusses the advantages of the transistor reset system and illustrates several configurations of the packages used for the FET and reset transistor. It also describes the preamplifer circuit and shows the performance of the spectrometer at high rates

  17. The performance of one belt and one road exchange rate: Based on improved singular spectrum analysis

    Science.gov (United States)

    Lai, Lin; Guo, Kun

    2017-10-01

    ;One Belt and One Road; strategy in China is on push of foreign trade openness at northwest, southwest and northeast, absorption of the excess capacity and new support for economic increase. However, the fluctuation in RMB exchange rate with the countries along the road is unstable so related Chinese enterprises will face high risk of exchange rate. Precise explanation or prediction for exchange rate has been the challengeable hop point in the international finance. This paper decomposed the One Belt One Road Exchange Rate Index (OBORR) and the RMB Effective Exchange Rate Index (CNYX) into trend term, market fluctuation term and noise term using improved singular spectrum analysis (SSA). It turns out that the increasing velocity of OBORR is greater than that of CNYX in the long term, and there is dynamic lead-lag structure in the medium term. In the short term, the fluctuation range and frequency of OBORR are greater than those of CNYX, which means there will be more exchange rate risks in One Belt and One Road countries.

  18. High Performance Processing and Analysis of Geospatial Data Using CUDA on GPU

    Directory of Open Access Journals (Sweden)

    STOJANOVIC, N.

    2014-11-01

    Full Text Available In this paper, the high-performance processing of massive geospatial data on many-core GPU (Graphic Processing Unit is presented. We use CUDA (Compute Unified Device Architecture programming framework to implement parallel processing of common Geographic Information Systems (GIS algorithms, such as viewshed analysis and map-matching. Experimental evaluation indicates the improvement in performance with respect to CPU-based solutions and shows feasibility of using GPU and CUDA for parallel implementation of GIS algorithms over large-scale geospatial datasets.

  19. Introduction to State Estimation of High-Rate System Dynamics.

    Science.gov (United States)

    Hong, Jonathan; Laflamme, Simon; Dodson, Jacob; Joyce, Bryan

    2018-01-13

    Engineering systems experiencing high-rate dynamic events, including airbags, debris detection, and active blast protection systems, could benefit from real-time observability for enhanced performance. However, the task of high-rate state estimation is challenging, in particular for real-time applications where the rate of the observer's convergence needs to be in the microsecond range. This paper identifies the challenges of state estimation of high-rate systems and discusses the fundamental characteristics of high-rate systems. A survey of applications and methods for estimators that have the potential to produce accurate estimations for a complex system experiencing highly dynamic events is presented. It is argued that adaptive observers are important to this research. In particular, adaptive data-driven observers are advantageous due to their adaptability and lack of dependence on the system model.

  20. Core-Shell Columns in High-Performance Liquid Chromatography: Food Analysis Applications

    OpenAIRE

    Preti, Raffaella

    2016-01-01

    The increased separation efficiency provided by the new technology of column packed with core-shell particles in high-performance liquid chromatography (HPLC) has resulted in their widespread diffusion in several analytical fields: from pharmaceutical, biological, environmental, and toxicological. The present paper presents their most recent applications in food analysis. Their use has proved to be particularly advantageous for the determination of compounds at trace levels or when a large am...

  1. Code structure for U-Mo fuel performance analysis in high performance research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Gwan Yoon; Cho, Tae Won; Lee, Chul Min; Sohn, Dong Seong [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of); Lee, Kyu Hong; Park, Jong Man [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    A performance analysis modeling applicable to research reactor fuel is being developed with available models describing fuel performance phenomena observed from in-pile tests. We established the calculation algorithm and scheme to best predict fuel performance using radio-thermo-mechanically coupled system to consider fuel swelling, interaction layer growth, pore formation in the fuel meat, and creep fuel deformation and mass relocation, etc. In this paper, we present a general structure of the performance analysis code for typical research reactor fuel and advanced features such as a model to predict fuel failure induced by combination of breakaway swelling and pore growth in the fuel meat. Thermo-mechanical code dedicated to the modeling of U-Mo dispersion fuel plates is being under development in Korea to satisfy a demand for advanced performance analysis and safe assessment of the plates. The major physical phenomena during irradiation are considered in the code such that interaction layer formation by fuel-matrix interdiffusion, fission induced swelling of fuel particle, mass relocation by fission induced stress, and pore formation at the interface between the reaction product and Al matrix.

  2. High frame rate retrospectively triggered Cine MRI for assessment of murine diastolic function.

    Science.gov (United States)

    Coolen, Bram F; Abdurrachim, Desiree; Motaal, Abdallah G; Nicolay, Klaas; Prompers, Jeanine J; Strijkers, Gustav J

    2013-03-01

    To assess left ventricular (LV) diastolic function in mice with Cine MRI, a high frame rate (>60 frames per cardiac cycle) is required. For conventional electrocardiography-triggered Cine MRI, the frame rate is inversely proportional to the pulse repetition time (TR). However, TR cannot be lowered at will to increase the frame rate because of gradient hardware, spatial resolution, and signal-to-noise limitations. To overcome these limitations associated with electrocardiography-triggered Cine MRI, in this paper, we introduce a retrospectively triggered Cine MRI protocol capable of producing high-resolution high frame rate Cine MRI of the mouse heart for addressing left ventricular diastolic function. Simulations were performed to investigate the influence of MRI sequence parameters and the k-space filling trajectory in relation to the desired number of frames per cardiac cycle. An optimized protocol was applied in vivo and compared with electrocardiography-triggered Cine for which a high-frame rate could only be achieved by several interleaved acquisitions. Retrospective high frame rate Cine MRI proved superior to the interleaved electrocardiography-triggered protocols. High spatial-resolution Cine movies with frames rates up to 80 frames per cardiac cycle were obtained in 25 min. Analysis of left ventricular filling rate curves allowed accurate determination of early and late filling rates and revealed subtle impairments in left ventricular diastolic function of diabetic mice in comparison with nondiabetic mice. Copyright © 2012 Wiley Periodicals, Inc.

  3. Facile Synthesis of Bowl-Like LiFePO4/C Composite with High Rate-Performance

    Science.gov (United States)

    Jing, Peng; Yao, Lei; Xiang, Mingwu; Wang, Yan; Wu, Jinhua; Wang, Boya; Zhang, Yun; Wu, Hao; Liu, Heng

    2018-03-01

    Olivine-structured LiFePO4/C composites with high rate-performance were synthesized via an industrial spray-drying technique using a low cost Fe3O4 as iron source. The as-obtained LiFePO4/C exhibits a unique bowl-like morphology with a particle size of 2-5 μm in diameter. A continuous uniform carbon coating layer on the surface of LiFePO4/C cathodes promotes fast electron transport, whilst it guarantees the favorable electrochemical reaction. Especially the formation of porous structure leads to an average pore volume of 0.127 cm3 g-1 and a high specific surface area of 34.46 m2 g-1, which is conducive to facilitating the penetration of electrolyte and providing the more contact area of electrolyte with LiFePO4/C. As a result, the as-prepared LiFePO4/C cathode material delivers an outstanding discharge capacity of 102.1 mAh g-1, 94.2% of the initial capacity (108.3 mAh g-1), after 1000 cycles at 10 C. Even at an ultrahigh current rate of 50 C, it still shows an initial discharge capacity of 58 mAh g-1.

  4. Facile Synthesis of Bowl-Like LiFePO4/C Composite with High Rate-Performance

    Science.gov (United States)

    Jing, Peng; Yao, Lei; Xiang, Mingwu; Wang, Yan; Wu, Jinhua; Wang, Boya; Zhang, Yun; Wu, Hao; Liu, Heng

    2018-07-01

    Olivine-structured LiFePO4/C composites with high rate-performance were synthesized via an industrial spray-drying technique using a low cost Fe3O4 as iron source. The as-obtained LiFePO4/C exhibits a unique bowl-like morphology with a particle size of 2-5 μm in diameter. A continuous uniform carbon coating layer on the surface of LiFePO4/C cathodes promotes fast electron transport, whilst it guarantees the favorable electrochemical reaction. Especially the formation of porous structure leads to an average pore volume of 0.127 cm3 g-1 and a high specific surface area of 34.46 m2 g-1, which is conducive to facilitating the penetration of electrolyte and providing the more contact area of electrolyte with LiFePO4/C. As a result, the as-prepared LiFePO4/C cathode material delivers an outstanding discharge capacity of 102.1 mAh g-1, 94.2% of the initial capacity (108.3 mAh g-1), after 1000 cycles at 10 C. Even at an ultrahigh current rate of 50 C, it still shows an initial discharge capacity of 58 mAh g-1.

  5. Analysis of air temperature changes on blood pressure and heart rate and performance of undergraduate students.

    Science.gov (United States)

    Siqueira, Joseana C F; da Silva, Luiz Bueno; Coutinho, Antônio S; Rodrigues, Rafaela M

    2017-01-01

    The increase in air temperature has been associated with human deaths, some of which are related to cardiovascular dysfunctions, and with the reduction of physical and cognitive performance in humans. To analyze the relationship between blood pressure (BP) and heart rate (HR) and the cognitive performance of students who were submitted to temperature changes in classrooms. The university students answered a survey that was adapted from the Battery of Reasoning Tests over 3 consecutive days at different air temperatures while their thermal state and HR were measured. During those 3 days, BP and HR were evaluated before and after the cognitive test. The average and final HR increased at high temperatures; the tests execution time was reduced at high temperatures; and the cognitive tests was related to Mean BP at the beginning of the test, the maximum HR during the test and the air temperature. The cognitive performance of undergraduate students in the field of engineering and technology will increase while performing activities in a learning environment with an air temperature of approximately 23.3°C (according to their thermal perception), if students have an initial MBP of 93.33 mmHg and a 60 bpm HRmax.

  6. Performance improvement of two-dimensional EUV spectroscopy based on high frame rate CCD and signal normalization method

    International Nuclear Information System (INIS)

    Zhang, H.M.; Morita, S.; Ohishi, T.; Goto, M.; Huang, X.L.

    2014-01-01

    In the Large Helical Device (LHD), the performance of two-dimensional (2-D) extreme ultraviolet (EUV) spectroscopy with wavelength range of 30-650A has been improved by installing a high frame rate CCD and applying a signal intensity normalization method. With upgraded 2-D space-resolved EUV spectrometer, measurement of 2-D impurity emission profiles with high horizontal resolution is possible in high-density NBI discharges. The variation in intensities of EUV emission among a few discharges is significantly reduced by normalizing the signal to the spectral intensity from EUV_—Long spectrometer which works as an impurity monitor with high-time resolution. As a result, high resolution 2-D intensity distribution has been obtained from CIV (384.176A), CV(2x40.27A), CVI(2x33.73A) and HeII(303.78A). (author)

  7. High-performance thin-layer chromatography analysis of steviol glycosides in Stevia formulations and sugar-free food products, and benchmarking with (ultra) high-performance liquid chromatography.

    Science.gov (United States)

    Morlock, Gertrud E; Meyer, Stephanie; Zimmermann, Benno F; Roussel, Jean-Marc

    2014-07-11

    A high-performance TLC (HPTLC) method was newly developed and validated for analysis of 7 steviol glycosides in 6 different types of food and Stevia formulations. After a minimized one-step sample preparation, 21 samples were developed in parallel, allowing an effective food screening. Depending on the sample application volume, the method was suited to analyze food sample concentrations in the mg/kg range. LOQs of stevioside in natural yoghurt matrix spiked at 0.02, 0.13 and 0.2% were determined by the calibration curve method to be 12ng/band (peak height). ANOVA was successfully passed to prove data homogeneity in the working range (30-600ng/band). The accuracy (recovery tolerance limit, 92-120%), repeatability (3.1-5.4%) and intermediate precision (4.0-8.4%) were determined for stevioside in milk-based matrix including sample preparation and recovery rates at 3 different concentration levels. For the first time, the recording of HPTLC-ESI-MS spectra via the TLC-MS Interface was demonstrated for rebaudioside A. HPTLC contents for rebaudioside A were compared with results of two (U)HPLC methods. The running costs and analysis time of the three different methods were discussed in detail with regard to screening of food products. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Aging analysis of high performance FinFET flip-flop under Dynamic NBTI simulation configuration

    Science.gov (United States)

    Zainudin, M. F.; Hussin, H.; Halim, A. K.; Karim, J.

    2018-03-01

    A mechanism known as Negative-bias Temperature Instability (NBTI) degrades a main electrical parameters of a circuit especially in terms of performance. So far, the circuit design available at present are only focussed on high performance circuit without considering the circuit reliability and robustness. In this paper, the main circuit performances of high performance FinFET flip-flop such as delay time, and power were studied with the presence of the NBTI degradation. The aging analysis was verified using a 16nm High Performance Predictive Technology Model (PTM) based on different commands available at Synopsys HSPICE. The results shown that the circuit under the longer dynamic NBTI simulation produces the highest impact in the increasing of gate delay and decrease in the average power reduction from a fresh simulation until the aged stress time under a nominal condition. In addition, the circuit performance under a varied stress condition such as temperature and negative stress gate bias were also studied.

  9. MULTIFRACTAL ANALYSIS OFTHE DYNAMICS OF TURKISHEXCHANGE RATE

    Directory of Open Access Journals (Sweden)

    Ezgi Gülbaş

    2013-01-01

    Full Text Available We perform a comparative study of applicability of the Multifractal DetrendedFluctuation Analysis (MFDFA and the Wavelet Transform Modulus Maxima(WTMM method in properly detecting ofmono- and multifractal character ofdata. After summarizing the theory behind both methods, we apply both methodson USD/TRY currency. The results show thatour data has multifractal nature butnot at high level and multifractality ispoorer if WTMM method is used. We alsoinvestigated whether other Eastern European country currencies, such as RussianRubble and Hungarian Forint have multifractal characters by using MFDFAmethod. Therefore, forecasters have often encountered in trying to predict theseexchange rates with models that do notincorporate any notion of inhomogeneitywill have little predictive power.

  10. Dynamical analysis of electrochemical wall shear rate measurements

    NARCIS (Netherlands)

    Steenhoven, van A.A.; Beucken, van den F.J.H.M.

    1991-01-01

    The performance of a circular electrochemical wall shear rate probe under unsteady flow conditions is analysed through a combined ezxperimental, numerical and analytical approach. The experiments are performed with a ferri- and ferrocyanide redox couple and compared to finite element analysis of the

  11. Performance analysis of photovoltaic thermal (PVT) water collectors

    International Nuclear Information System (INIS)

    Fudholi, Ahmad; Sopian, Kamaruzzaman; Yazdi, Mohammad H.; Ruslan, Mohd Hafidz; Ibrahim, Adnan; Kazem, Hussein A.

    2014-01-01

    Highlights: • Performances analysis of PVT collector based on energy efficiencies. • New absorber designs of PVT collectors were presented. • Comparison present study with other absorber collector designs was presented. • High efficiencies were obtained for spiral flow absorber. - Abstract: The electrical and thermal performances of photovoltaic thermal (PVT) water collectors were determined under 500–800 W/m 2 solar radiation levels. At each solar radiation level, mass flow rates ranging from 0.011 kg/s to 0.041 kg/s were introduced. The PVT collectors were tested with respect to PV efficiency, thermal efficiency, and a combination of both (PVT efficiency). The results show that the spiral flow absorber exhibited the highest performance at a solar radiation level of 800 W/m 2 and mass flow rate of 0.041 kg/s. This absorber produced a PVT efficiency of 68.4%, a PV efficiency of 13.8%, and a thermal efficiency of 54.6%. It also produced a primary-energy saving efficiency ranging from 79% to 91% at a mass flow rate of 0.011–0.041 kg/s

  12. Resource management for multimedia services in high data rate wireless networks

    CERN Document Server

    Zhang, Ruonan; Pan, Jianping

    2017-01-01

    This brief offers a valuable resource on principles of quality-of-service (QoS) provisioning and the related link-layer resource management techniques for high data-rate wireless networks. The primary emphasis is on protocol modeling and analysis. It introduces media access control (MAC) protocols, standards of wireless local area networks (WLANs), wireless personal area networks (WPANs), and wireless body area networks (WBANs), discussing their key technologies, applications, and deployment scenarios. The main analytical approaches and models for performance analysis of the fundamental resource scheduling mechanisms, including the contention-based, reservation-based, and hybrid MAC, are presented. To help readers understand and evaluate system performance, the brief contains a range of simulation results. In addition, a thorough bibliography provides an additional tool. This brief is an essential resource for engineers, researchers, students, and users of wireless networks.

  13. Denaturing high-performance liquid chromatography mutation analysis in patients with reduced Protein S levels

    DEFF Research Database (Denmark)

    Bathum, Lise; Münster, Anna-Marie; Nybo, Mads

    2008-01-01

    diagnosis and risk estimation. The aim was to design a high-throughput genetic analysis based on denaturing high-performance liquid chromatography to identify sequence variations in the gene coding for Protein S. PATIENTS: In total, 55 patients referred to the Section of Thrombosis and Haemostasis, Odense......BACKGROUND: Patients with congenital Protein S deficiency have increased risk of venous thromboembolism. However, Protein S levels show large intra-individual variation and the biochemical assays have low accuracy and a high interlaboratory variability. Genetic analysis might aid in a more precise......, giving a precise diagnosis and subsequently a better risk estimation....

  14. Finite element analysis of the high strain rate testing of polymeric materials

    International Nuclear Information System (INIS)

    Gorwade, C V; Ashcroft, I A; Silberschmidt, V V; Alghamdi, A S; Song, M

    2012-01-01

    Advanced polymer materials are finding an increasing range of industrial and defence applications. Ultra-high molecular weight polymers (UHMWPE) are already used in lightweight body armour because of their good impact resistance with light weight. However, a broader use of such materials is limited by the complexity of the manufacturing processes and the lack of experimental data on their behaviour and failure evolution under high-strain rate loading conditions. The current study deals with an investigation of the internal heat generation during tensile of UHMWPE. A 3D finite element (FE) model of the tensile test is developed and validated the with experimental work. An elastic-plastic material model is used with adiabatic heat generation. The temperature and stresses obtained with FE analysis are found to be in a good agreement with the experimental results. The model can be used as a simple and cost effective tool to predict the thermo-mechanical behaviour of UHMWPE part under various loading conditions.

  15. Finite element analysis of the high strain rate testing of polymeric materials

    Science.gov (United States)

    Gorwade, C. V.; Alghamdi, A. S.; Ashcroft, I. A.; Silberschmidt, V. V.; Song, M.

    2012-08-01

    Advanced polymer materials are finding an increasing range of industrial and defence applications. Ultra-high molecular weight polymers (UHMWPE) are already used in lightweight body armour because of their good impact resistance with light weight. However, a broader use of such materials is limited by the complexity of the manufacturing processes and the lack of experimental data on their behaviour and failure evolution under high-strain rate loading conditions. The current study deals with an investigation of the internal heat generation during tensile of UHMWPE. A 3D finite element (FE) model of the tensile test is developed and validated the with experimental work. An elastic-plastic material model is used with adiabatic heat generation. The temperature and stresses obtained with FE analysis are found to be in a good agreement with the experimental results. The model can be used as a simple and cost effective tool to predict the thermo-mechanical behaviour of UHMWPE part under various loading conditions.

  16. Calculation and Analysis of B/T (Burning and/or Transmutation Rate of Minor Actinides and Plutonium Performed by Fast B/T Reactor

    Directory of Open Access Journals (Sweden)

    Marsodi

    2006-01-01

    Full Text Available Calculation and analysis of B/T (Burning and/or Transmutation rate of MA (minor actinides and Pu (Plutonium has been performed in fast B/T reactor. The study was based on the assumption that the spectrum shift of neutron flux to higher side of neutron energy had a potential significance for designing the fast B/T reactor and a remarkable effect for increasing the B/T rate of MA and/or Pu. The spectrum shifts of neutron have been performed by change MOX to metallic fuel. Blending fraction of MA and or Pu in B/T fuel and the volume ratio of fuel to coolant in the reactor core were also considered. Here, the performance of fast B/T reactor was evaluated theoretically based on the calculation results of the neutronics and burn-up analysis. In this study, the B/T rate of MA and/or Pu increased by increasing the blending fraction of MA and or Pu and by changing the F/C ratio. According to the results, the total B/T rate, i.e. [B/T rate]MA + [B/T rate]Pu, could be kept nearly constant under the critical condition, if the sum of the MA and Pu inventory in the core is nearly constant. The effect of loading structure was examined for inner or outer loading of concentric geometry and for homogeneous loading. Homogeneous loading of B/T fuel was the good structure for obtaining the higher B/T rate, rather than inner or outer loading

  17. gHRV: Heart rate variability analysis made easy.

    Science.gov (United States)

    Rodríguez-Liñares, L; Lado, M J; Vila, X A; Méndez, A J; Cuesta, P

    2014-08-01

    In this paper, the gHRV software tool is presented. It is a simple, free and portable tool developed in python for analysing heart rate variability. It includes a graphical user interface and it can import files in multiple formats, analyse time intervals in the signal, test statistical significance and export the results. This paper also contains, as an example of use, a clinical analysis performed with the gHRV tool, namely to determine whether the heart rate variability indexes change across different stages of sleep. Results from tests completed by researchers who have tried gHRV are also explained: in general the application was positively valued and results reflect a high level of satisfaction. gHRV is in continuous development and new versions will include suggestions made by testers. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Nitrogen-doped hierarchical porous carbon materials prepared from meta-aminophenol formaldehyde resin for supercapacitor with high rate performance

    International Nuclear Information System (INIS)

    Zhou, Jin; Zhang, Zhongshen; Xing, Wei; Yu, Jing; Han, Guoxing; Si, Weijiang; Zhuo, Shuping

    2015-01-01

    Graphical abstract: N-doped hierarchical porous carbons with high rate capacitive performance are prepared by a combination method of nano-SiO 2 template/KOH activation. - Highlights: • A mass produced nano-SiO 2 is used to prepared hierarchical porous carbon. • N-doped hierarchical porous carbon materials are easily prepared. • The NHPCs materials exhibit a very high capacitance of up to 260.5 F g −1 . • The NHPC-800 sample shows very high rate capability. • Hierarchical porosity and N-doping synergistically enhances the whole capacitance. - Abstract: In this work, nitrogen-doped hierarchical porous carbon materials (NHPCs) are prepared by a two-step method combined of a hard template process and KOH-activation treatment. Low cost and large-scale commercial nano-SiO 2 are used as a hard template. The hierarchical porosity, structure and nitrogen-doped surface chemical properties are proved by a varies of means, such as scanning electron microscopy, transition electron microscopy, N 2 sorption, Raman spectroscopy, X-ray diffraction and X-ray photoelectron spectroscopy. When the prepared NHPCs materials are used as the electrode materials for supercapacitors in KOH electrolyte, they exhibit very high specific capacitance, good power capability and excellent cyclic stability. NHPC-800 carbon shows a high capacitance of 114.0 F g −1 at the current density of 40 A g −1 , responding to a high energy and power densities of 4.0 Wh kg −1 and 10 000 W kg −1 , and a very short drain time of 1.4 s. The excellent capacitive performance may be due to the synergistic effect of the hierarchical porosity, high effective surface area and heteroatom doping, resulting in both electrochemical double layer and Faradaic capacitance contributions

  19. High performance fuel technology development

    Energy Technology Data Exchange (ETDEWEB)

    Koon, Yang Hyun; Kim, Keon Sik; Park, Jeong Yong; Yang, Yong Sik; In, Wang Kee; Kim, Hyung Kyu [KAERI, Daejeon (Korea, Republic of)

    2012-01-15

    {omicron} Development of High Plasticity and Annular Pellet - Development of strong candidates of ultra high burn-up fuel pellets for a PCI remedy - Development of fabrication technology of annular fuel pellet {omicron} Development of High Performance Cladding Materials - Irradiation test of HANA claddings in Halden research reactor and the evaluation of the in-pile performance - Development of the final candidates for the next generation cladding materials. - Development of the manufacturing technology for the dual-cooled fuel cladding tubes. {omicron} Irradiated Fuel Performance Evaluation Technology Development - Development of performance analysis code system for the dual-cooled fuel - Development of fuel performance-proving technology {omicron} Feasibility Studies on Dual-Cooled Annular Fuel Core - Analysis on the property of a reactor core with dual-cooled fuel - Feasibility evaluation on the dual-cooled fuel core {omicron} Development of Design Technology for Dual-Cooled Fuel Structure - Definition of technical issues and invention of concept for dual-cooled fuel structure - Basic design and development of main structure components for dual- cooled fuel - Basic design of a dual-cooled fuel rod.

  20. Estimating Driving Performance Based on EEG Spectrum Analysis

    Directory of Open Access Journals (Sweden)

    Jung Tzyy-Ping

    2005-01-01

    Full Text Available The growing number of traffic accidents in recent years has become a serious concern to society. Accidents caused by driver's drowsiness behind the steering wheel have a high fatality rate because of the marked decline in the driver's abilities of perception, recognition, and vehicle control abilities while sleepy. Preventing such accidents caused by drowsiness is highly desirable but requires techniques for continuously detecting, estimating, and predicting the level of alertness of drivers and delivering effective feedbacks to maintain their maximum performance. This paper proposes an EEG-based drowsiness estimation system that combines electroencephalogram (EEG log subband power spectrum, correlation analysis, principal component analysis, and linear regression models to indirectly estimate driver's drowsiness level in a virtual-reality-based driving simulator. Our results demonstrated that it is feasible to accurately estimate quantitatively driving performance, expressed as deviation between the center of the vehicle and the center of the cruising lane, in a realistic driving simulator.

  1. Sensitivity of monthly heart rate and psychometric measures for monitoring physical performance in highly trained young handball players.

    Science.gov (United States)

    Buchheit, M

    2015-05-01

    The aim of the present study was to examine whether monthly resting heart rate (HR), HR variability (HRV) and psychometric measures can be used to monitor changes in physical performance in highly-trained adolescent handball players. Data were collected in 37 adolescent players (training 10±2.1 h.wk(-1)) on 11 occasions from September to May during the in-season period, and included an estimation of training status (resting HR and HRV, the profile of mood state (POMS) questionnaire), and 3 physical performance tests (a 10-m sprint, a counter movement jump and a graded aerobic intermittent test, 30-15 Intermittent Fitness Test). The sensitivity of HR and psychometric measures to changes in physical performance was poor ( 75%), irrespective of the markers and the performance measures. Finally, the difference in physical performance between players with better vs. worse estimated training status were all almost certainly trivial. The present results highlight the limitation of monthly measures of resting HR, HRV and perceived mood and fatigue for predicting in-season changes in physical performance in highly-trained adolescent handball players. This suggests that more frequent monitoring might be required, and/or that other markers might need to be considered. © Georg Thieme Verlag KG Stuttgart · New York.

  2. The Performance Measurement of Enterprises Traded in Borsa Istanbul the Emerging Companies Market with Grey Relational Analysis

    Directory of Open Access Journals (Sweden)

    Kadir TUNA

    2013-12-01

    Full Text Available In this study, the performance measurement of eleven enterprises traded in Borsa Istanbul the Emerging Companies Market was performed. For this aim, six-rates were obtained by using the balance sheet and income statement data of the year 2011. The Grey Relational Analysis was applied by using these rates. As a result of the analysis, it was concluded that Denge Yatirim Holding Inc. (DENGE had the highest performance. Furthermore, it was found that the rates of net profit/total assets, net profit/capital stock, net profit/net sales of DENGE had high profitability ratios values.

  3. Hydrostatic Stress Effects Incorporated Into the Analysis of the High-Strain-Rate Deformation of Polymer Matrix Composites

    Science.gov (United States)

    Goldberg, Robert K.; Roberts, Gary D.

    2003-01-01

    Procedures for modeling the effect of high strain rate on composite materials are needed for designing reliable composite engine cases that are lighter than the metal cases in current use. The types of polymer matrix composites that are likely to be used in such an application have a deformation response that is nonlinear and that varies with strain rate. The nonlinearity and strain rate dependence of the composite response is primarily due to the matrix constituent. Therefore, in developing material models to be used in the design of impact-resistant composite engine cases, the deformation of the polymer matrix must be correctly analyzed. However, unlike in metals, the nonlinear response of polymers depends on the hydrostatic stresses, which must be accounted for within an analytical model. An experimental program has been carried out through a university grant with the Ohio State University to obtain tensile and shear deformation data for a representative polymer for strain rates ranging from quasi-static to high rates of several hundred per second. This information has been used at the NASA Glenn Research Center to develop, characterize, and correlate a material model in which the strain rate dependence and nonlinearity (including hydrostatic stress effects) of the polymer are correctly analyzed. To obtain the material data, Glenn s researchers designed and fabricated test specimens of a representative toughened epoxy resin. Quasi-static tests at low strain rates and split Hopkinson bar tests at high strain rates were then conducted at the Ohio State University. The experimental data confirmed the strong effects of strain rate on both the tensile and shear deformation of the polymer. For the analytical model, Glenn researchers modified state variable constitutive equations previously used for the viscoplastic analysis of metals to allow for the analysis of the nonlinear, strain-rate-dependent polymer deformation. Specifically, we accounted for the effects of

  4. National cyber defense high performance computing and analysis : concepts, planning and roadmap.

    Energy Technology Data Exchange (ETDEWEB)

    Hamlet, Jason R.; Keliiaa, Curtis M.

    2010-09-01

    There is a national cyber dilemma that threatens the very fabric of government, commercial and private use operations worldwide. Much is written about 'what' the problem is, and though the basis for this paper is an assessment of the problem space, we target the 'how' solution space of the wide-area national information infrastructure through the advancement of science, technology, evaluation and analysis with actionable results intended to produce a more secure national information infrastructure and a comprehensive national cyber defense capability. This cybersecurity High Performance Computing (HPC) analysis concepts, planning and roadmap activity was conducted as an assessment of cybersecurity analysis as a fertile area of research and investment for high value cybersecurity wide-area solutions. This report and a related SAND2010-4765 Assessment of Current Cybersecurity Practices in the Public Domain: Cyber Indications and Warnings Domain report are intended to provoke discussion throughout a broad audience about developing a cohesive HPC centric solution to wide-area cybersecurity problems.

  5. Phase-Separated Polyaniline/Graphene Composite Electrodes for High-Rate Electrochemical Supercapacitors.

    Science.gov (United States)

    Wu, Jifeng; Zhang, Qin'e; Zhou, An'an; Huang, Zhifeng; Bai, Hua; Li, Lei

    2016-12-01

    Polyaniline/graphene hydrogel composites with a macroscopically phase-separated structure are prepared. The composites show high specific capacitance and excellent rate performance. Further investigation demonstrates that polyaniline inside the graphene hydrogel has low rate performance, thus a phase-separated structure, in which polyaniline is mainly outside the graphene hydrogel matrix, can enhance the rate performance of the composites. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. High Rate Performing Li-ion Battery

    Science.gov (United States)

    2015-02-09

    journal article will be sufficient in most cases. This document may be as long or as short as needed to give a fair account of the work performed...Klink, J. J. & Moser, J. EPR Study of Vanadium (4+) in the Anatase and Rutile Phases of TiO2. Phys. Rev. B 34, 3060-3068 (1986). 40 Abragam, A

  7. Speciation analysis of cobalt in foods by high-performance liquid chromatography and neutron activation analysis

    International Nuclear Information System (INIS)

    Muto, Toshio; Koyama, Motoko

    1994-01-01

    A combined method by coupling high-performance liquid chromatography (HPLC, as a separation method) with neutron activation analysis (as a detection method) have been applied to the speciation analysis of cobalt in daily foods (e.g. egg, fish and milk). Cobalt species including free cobalt, vitamin B 12 and protein-bound cobalt were separated with a preparative HPLC and a centrifuge. Subsequently, the determination of cobalt in the separated species was made by neutron activation analysis. The results showed that the content of the total cobalt in the foods was found to lie in the range 0.4-11ng/g(0.4-11ppb) based on wet weight. The compositions of free cobalt, vitamin B 12 and protein-bound cobalt were ranged 16-43%, 55-73%, 2.3-17%, respectively. These experimental evidences suggest that the combination of HPLC and neutron activation analysis is expected to be a useful tool for speciation analysis of trace elements in biological as well as environmental materials. (author)

  8. Integrated approach for stress analysis of high performance diesel engine cylinder head

    Science.gov (United States)

    Chainov, N. D.; Myagkov, L. L.; Malastowski, N. S.; Blinov, A. S.

    2018-03-01

    Growing thermal and mechanical loads due to development of engines with high level of a mean effective pressure determine requirements to cylinder head durability. In this paper, computational schemes for thermal and mechanical stress analysis of a high performance diesel engine cylinder head were described. The most important aspects in this approach are the account of temperature fields of conjugated details (valves and saddles), heat transfer modeling in a cooling jacket of a cylinder head and topology optimization of the detail force scheme. Simulation results are shown and analyzed.

  9. High resolution gamma-ray spectroscopy at high count rates with a prototype High Purity Germanium detector

    Science.gov (United States)

    Cooper, R. J.; Amman, M.; Vetter, K.

    2018-04-01

    High-resolution gamma-ray spectrometers are required for applications in nuclear safeguards, emergency response, and fundamental nuclear physics. To overcome one of the shortcomings of conventional High Purity Germanium (HPGe) detectors, we have developed a prototype device capable of achieving high event throughput and high energy resolution at very high count rates. This device, the design of which we have previously reported on, features a planar HPGe crystal with a reduced-capacitance strip electrode geometry. This design is intended to provide good energy resolution at the short shaping or digital filter times that are required for high rate operation and which are enabled by the fast charge collection afforded by the planar geometry crystal. In this work, we report on the initial performance of the system at count rates up to and including two million counts per second.

  10. Dynamic High-Temperature Characterization of an Iridium Alloy in Compression at High Strain Rates

    Energy Technology Data Exchange (ETDEWEB)

    Song, Bo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Experimental Environment Simulation Dept.; Nelson, Kevin [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Mechanics of Materials Dept.; Lipinski, Ronald J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Nuclear Fuel Cycle Technology Dept.; Bignell, John L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Structural and Thermal Analysis Dept.; Ulrich, G. B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Radioisotope Power Systems Program; George, E. P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Radioisotope Power Systems Program

    2014-06-01

    Iridium alloys have superior strength and ductility at elevated temperatures, making them useful as structural materials for certain high-temperature applications. However, experimental data on their high-temperature high-strain-rate performance are needed for understanding high-speed impacts in severe elevated-temperature environments. Kolsky bars (also called split Hopkinson bars) have been extensively employed for high-strain-rate characterization of materials at room temperature, but it has been challenging to adapt them for the measurement of dynamic properties at high temperatures. Current high-temperature Kolsky compression bar techniques are not capable of obtaining satisfactory high-temperature high-strain-rate stress-strain response of thin iridium specimens investigated in this study. We analyzed the difficulties encountered in high-temperature Kolsky compression bar testing of thin iridium alloy specimens. Appropriate modifications were made to the current high-temperature Kolsky compression bar technique to obtain reliable compressive stress-strain response of an iridium alloy at high strain rates (300 – 10000 s-1) and temperatures (750°C and 1030°C). Uncertainties in such high-temperature high-strain-rate experiments on thin iridium specimens were also analyzed. The compressive stress-strain response of the iridium alloy showed significant sensitivity to strain rate and temperature.

  11. Fluorescence decay data analysis correcting for detector pulse pile-up at very high count rates

    Science.gov (United States)

    Patting, Matthias; Reisch, Paja; Sackrow, Marcus; Dowler, Rhys; Koenig, Marcelle; Wahl, Michael

    2018-03-01

    Using time-correlated single photon counting for the purpose of fluorescence lifetime measurements is usually limited in speed due to pile-up. With modern instrumentation, this limitation can be lifted significantly, but some artifacts due to frequent merging of closely spaced detector pulses (detector pulse pile-up) remain an issue to be addressed. We propose a data analysis method correcting for this type of artifact and the resulting systematic errors. It physically models the photon losses due to detector pulse pile-up and incorporates the loss in the decay fit model employed to obtain fluorescence lifetimes and relative amplitudes of the decay components. Comparison of results with and without this correction shows a significant reduction of systematic errors at count rates approaching the excitation rate. This allows quantitatively accurate fluorescence lifetime imaging at very high frame rates.

  12. Influence of transmission bit rate on performance of optical fibre communication systems with direct modulation of laser diodes

    International Nuclear Information System (INIS)

    Ahmed, Moustafa F

    2009-01-01

    This paper reports on the influence of the transmission bit rate on the performance of optical fibre communication systems employing laser diodes subjected to high-speed direct modulation. The performance is evaluated in terms of the bit error rate (BER) and power penalty associated with increasing the transmission bit rate while keeping the transmission distance. The study is based on numerical analysis of the stochastic rate equations of the laser diode and takes into account noise mechanisms in the receiver. Correlation between BER and the Q-parameter of the received signal is presented. The relative contributions of the transmitter noise and the circuit and shot noises of the receiver to BER are quantified as functions of the transmission bit rate. The results show that the power penalty at BER = 10 -9 required to keep the transmission distance increases moderately with the increase in the bit rate near 1 Gbps and at high bias currents. In this regime, the shot noise is the main contributor to BER. At higher bit rates and lower bias currents, the power penalty increases remarkably, which comes mainly from laser noise induced by the pseudorandom bit-pattern effect.

  13. High-speed counter-current chromatography coupled online to high performance liquid chromatography-diode array detector-mass spectrometry for purification, analysis and identification of target compounds from natural products.

    Science.gov (United States)

    Liang, Xuejuan; Zhang, Yuping; Chen, Wei; Cai, Ping; Zhang, Shuihan; Chen, Xiaoqin; Shi, Shuyun

    2015-03-13

    A challenge in coupling high-speed counter-current chromatography (HSCCC) online with high performance liquid chromatography (HPLC) for purity analysis was their time incompatibility. Consequently, HSCCC-HPLC was conducted by either controlling HPLC analysis time and HSCCC flow rate or using stop-and-go scheme. For natural products containing compounds with a wide range of polarities, the former would optimize experimental conditions, while the latter required more time. Here, a novel HSCCC-HPLC-diode array detector-mass spectrometry (HSCCC-HPLC-DAD-MS) was developed for undisrupted purification, analysis and identification of multi-compounds from natural products. Two six-port injection valves and a six-port switching valve were used as interface for collecting key HSCCC effluents alternatively for HPLC-DAD-MS analysis and identification. The ethyl acetate extract of Malus doumeri was performed on the hyphenated system to verify its efficacy. Five main flavonoids, 3-hydroxyphloridzin (1), phloridzin (2), 4',6'-dihydroxyhydrochalcone-2'-O-β-D-glucopyranoside (3, first found in M. doumeri), phloretin (4), and chrysin (5), were purified with purities over 99% by extrusion elution and/or stepwise elution mode in two-step HSCCC, and 25mM ammonium acetate solution was selected instead of water to depress emulsification in the first HSCCC. The online system shortened manipulation time largely compared with off-line analysis procedure and stop-and-go scheme. The results indicated that the present method could serve as a simple, rapid and effective way to achieve target compounds with high purity from natural products. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Preliminary Evaluation of MapReduce for High-Performance Climate Data Analysis

    Science.gov (United States)

    Duffy, Daniel Q.; Schnase, John L.; Thompson, John H.; Freeman, Shawn M.; Clune, Thomas L.

    2012-01-01

    MapReduce is an approach to high-performance analytics that may be useful to data intensive problems in climate research. It offers an analysis paradigm that uses clusters of computers and combines distributed storage of large data sets with parallel computation. We are particularly interested in the potential of MapReduce to speed up basic operations common to a wide range of analyses. In order to evaluate this potential, we are prototyping a series of canonical MapReduce operations over a test suite of observational and climate simulation datasets. Our initial focus has been on averaging operations over arbitrary spatial and temporal extents within Modern Era Retrospective- Analysis for Research and Applications (MERRA) data. Preliminary results suggest this approach can improve efficiencies within data intensive analytic workflows.

  15. ANALISIS RESIDU KLORPIRIFOS DALAM SAYUR-SAYURAN DENGAN TEKNIK HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC

    Directory of Open Access Journals (Sweden)

    Aman Sentosa Panggabean

    2016-06-01

    Full Text Available The research about analysis of chlorpyrifos residue in vegetables by using High Performance Liquid Chromatography (HPLC technique has been done. To obtain the optimal measurement results, the measurement performed several important parameters in the chromatographic system was composition of mobile phase, volume injection sample, flow rate and pH eluent. Optimum measurement conditions obtained was mobile phase composition (water : methanol with 70 : 30, volume injection sample are 5 mL, flow rate are 0.5mL/menit and pH eluent are 7. The analytical performance that obtained is good showed with the reproducibility value as percentage coefficient variance (% CV was 0.0664%, limit of detection (LOD was 0.44 ppm, with a recovery percentage of > 95%. The results obtained showed the HPLC technique can be used for the routine analysis in the determination of chlorpyrifos for the vegetable samples. Keywords: Chlorpyrifos, Vegetables, HPLC.

  16. Integrated State Estimation and Contingency Analysis Software Implementation using High Performance Computing Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yousu; Glaesemann, Kurt R.; Rice, Mark J.; Huang, Zhenyu

    2015-12-31

    Power system simulation tools are traditionally developed in sequential mode and codes are optimized for single core computing only. However, the increasing complexity in the power grid models requires more intensive computation. The traditional simulation tools will soon not be able to meet the grid operation requirements. Therefore, power system simulation tools need to evolve accordingly to provide faster and better results for grid operations. This paper presents an integrated state estimation and contingency analysis software implementation using high performance computing techniques. The software is able to solve large size state estimation problems within one second and achieve a near-linear speedup of 9,800 with 10,000 cores for contingency analysis application. The performance evaluation is presented to show its effectiveness.

  17. Conference on High Performance Software for Nonlinear Optimization

    CERN Document Server

    Murli, Almerico; Pardalos, Panos; Toraldo, Gerardo

    1998-01-01

    This book contains a selection of papers presented at the conference on High Performance Software for Nonlinear Optimization (HPSN097) which was held in Ischia, Italy, in June 1997. The rapid progress of computer technologies, including new parallel architec­ tures, has stimulated a large amount of research devoted to building software environments and defining algorithms able to fully exploit this new computa­ tional power. In some sense, numerical analysis has to conform itself to the new tools. The impact of parallel computing in nonlinear optimization, which had a slow start at the beginning, seems now to increase at a fast rate, and it is reasonable to expect an even greater acceleration in the future. As with the first HPSNO conference, the goal of the HPSN097 conference was to supply a broad overview of the more recent developments and trends in nonlinear optimization, emphasizing the algorithmic and high performance software aspects. Bringing together new computational methodologies with theoretical...

  18. Fast analysis of curcuminoids from turmeric (Curcuma longa L.) by high-performance liquid chromatography using a fused-core column.

    Science.gov (United States)

    Osorio-Tobón, J Felipe; Carvalho, Pedro I N; Barbero, Gerardo Fernández; Nogueira, Gislaine Chrystina; Rostagno, Mauricio Ariel; Meireles, Maria Angela de Almeida

    2016-06-01

    The recent development of fused-core technology in HPLC columns is enabling faster and highly efficient separations. This technology was evaluated for the development of a fast method for the analysis of main curcuminoids (curcumin, demethoxycurcumin and bisdemethoxycurcumin) present in extracts of turmeric (Curcuma longa L.). A step-by-step strategy was used to optimize temperature (40-55 °C), flow rate (1.0-2.5 mL min(-1)), mobile phase composition and equilibration time (1-5 min). A gradient method was developed using acidified water and acetonitrile combined with high column temperature (55 °C) and flow rate (2.5 mL min(-1)). Optimized conditions provided a method for the separation of these three curcuminoids in approximately 1.3 min with a total analysis time (sample-to-sample) of 7 min, including the clean-up and the re-equilibration of the column. Evaluation of chromatographic performance revealed excellent intraday and interday reproducibility (>99%), resolution (>2.23), selectivity (>1.12), peak symmetry (1.24-1.42) while presenting low limits of detection (<0.40 mg L(-1)) and quantification (<1.34 mg L(-1)). The robustness of the method was calculated according to the concentration/dilution of the sample and the injection volume. Several combinations of methanol and ethanol with water as sample solvents were evaluated and the best chromatographic results and extraction rate were obtained using 100% methanol. Finally, the developed method was validated with different extracts of turmeric rhizome and products that use turmeric in their formulation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Design of a high repetition rate S-band photocathode gun

    International Nuclear Information System (INIS)

    Han Janghui; Cox, Matthew; Huang, Houcheng; Pande, Shivaji

    2011-01-01

    Photocathode RF guns have been developed in many laboratories for generating high quality electron beams for free-electron lasers based on linear accelerators. Such guns can generate electron beams with an exceptionally high peak current as well as a small transverse emittance. Their applications have been recently expanded for ultrafast electron diffraction, coherent terahertz radiation, and X-ray or γ-ray radiation by Compton scattering. In this paper, we design an S-band normal-conducting gun with capabilities of high quality beam generation and high repetition rate operation. The RF design and thermal analysis of the gun cavity and coupler are introduced. Optimal position of the gun focusing solenoid for low emittance beam generation is found by performing particle tracking simulations. Then, the gun system is designed to be able to afford the optimal solenoid position. The cooling-water channel surrounding the gun cavity and coupler is designed and analyzed numerically. The pressure in the gun is simulated with a vacuum model containing the detailed inner structure of the gun. An injector for a free-electron laser application is designed by using this gun and the beam dynamics simulation is shown. A cold test with a prototype gun for confirmation of the RF design is reported. - Highlights: → We design an S-band gun for low emittance beam generation and high repetition rate operation. → The RF design and thermal analysis of the gun cavity and coupler are studied. → An FEL injector is designed by using this gun and the beam dynamics simulation is shown. → A cold test with a prototype gun for confirmation of the RF design is reported.

  20. High strain rate behaviour of polypropylene microfoams

    Science.gov (United States)

    Gómez-del Río, T.; Garrido, M. A.; Rodríguez, J.; Arencón, D.; Martínez, A. B.

    2012-08-01

    Microcellular materials such as polypropylene foams are often used in protective applications and passive safety for packaging (electronic components, aeronautical structures, food, etc.) or personal safety (helmets, knee-pads, etc.). In such applications the foams which are used are often designed to absorb the maximum energy and are generally subjected to severe loadings involving high strain rates. The manufacture process to obtain polymeric microcellular foams is based on the polymer saturation with a supercritical gas, at high temperature and pressure. This method presents several advantages over the conventional injection moulding techniques which make it industrially feasible. However, the effect of processing conditions such as blowing agent, concentration and microfoaming time and/or temperature on the microstructure of the resulting microcellular polymer (density, cell size and geometry) is not yet set up. The compressive mechanical behaviour of several microcellular polypropylene foams has been investigated over a wide range of strain rates (0.001 to 3000 s-1) in order to show the effects of the processing parameters and strain rate on the mechanical properties. High strain rate tests were performed using a Split Hopkinson Pressure Bar apparatus (SHPB). Polypropylene and polyethylene-ethylene block copolymer foams of various densities were considered.

  1. Performance Analysis of Modified Drain Gating Techniques for Low Power and High Speed Arithmetic Circuits

    Directory of Open Access Journals (Sweden)

    Shikha Panwar

    2014-01-01

    Full Text Available This paper presents several high performance and low power techniques for CMOS circuits. In these design methodologies, drain gating technique and its variations are modified by adding an additional NMOS sleep transistor at the output node which helps in faster discharge and thereby providing higher speed. In order to achieve high performance, the proposed design techniques trade power for performance in the delay critical sections of the circuit. Intensive simulations are performed using Cadence Virtuoso in a 45 nm standard CMOS technology at room temperature with supply voltage of 1.2 V. Comparative analysis of the present circuits with standard CMOS circuits shows smaller propagation delay and lesser power consumption.

  2. Authoritative School Climate and High School Dropout Rates

    Science.gov (United States)

    Jia, Yuane; Konold, Timothy R.; Cornell, Dewey

    2016-01-01

    This study tested the association between school-wide measures of an authoritative school climate and high school dropout rates in a statewide sample of 315 high schools. Regression models at the school level of analysis used teacher and student measures of disciplinary structure, student support, and academic expectations to predict overall high…

  3. Toxic Compounds Analysis With High Performance Liquid Chromatography Detected By Electro Chemical Detector (Ecd)

    OpenAIRE

    Hideharu Shintaniq

    2014-01-01

    The principal area of application of high performance liquid chromatography-electrochemical detector (HPLC-ECD) has been in the analysis of naturally-occurring analytes, such as catecholamines, and pharmaceuticals in biological samples, HPLC-ECD has also applied to the analysis of pesticides and other analytes of interest to the toxicologist. In this paper, toxic area is described. In these, ammatoxins, aromatic amine, nitro-compounds, algal toxins, fungal toxins, pesticides, veterinary drug ...

  4. A Meta-analysis on Resting State High-frequency Heart Rate Variability in Bulimia Nervosa.

    Science.gov (United States)

    Peschel, Stephanie K V; Feeling, Nicole R; Vögele, Claus; Kaess, Michael; Thayer, Julian F; Koenig, Julian

    2016-09-01

    Autonomic nervous system function is altered in eating disorders. We aimed to quantify differences in resting state vagal activity, indexed by high-frequency heart rate variability comparing patients with bulimia nervosa (BN) and healthy controls. A systematic search of the literature to identify studies eligible for inclusion and meta-analytical methods were applied. Meta-regression was used to identify potential covariates. Eight studies reporting measures of resting high-frequency heart rate variability in individuals with BN (n = 137) and controls (n = 190) were included. Random-effects meta-analysis revealed a sizeable main effect (Z = 2.22, p = .03; Hedge's g = 0.52, 95% CI [0.06;0.98]) indicating higher resting state vagal activity in individuals with BN. Meta-regression showed that body mass index and medication intake are significant covariates. Findings suggest higher vagal activity in BN at rest, particularly in unmedicated samples with lower body mass index. Potential mechanisms underlying these findings and implications for routine clinical care are discussed. Copyright © 2016 John Wiley & Sons, Ltd and Eating Disorders Association. Copyright © 2016 John Wiley & Sons, Ltd and Eating Disorders Association.

  5. Performance and safety analysis of WP-cave concept

    International Nuclear Information System (INIS)

    Skagius, K.; Svemar, C.

    1989-08-01

    The report presents a performance safety, and cost analysis of the WP-cave, WPC, concept. In the performance analysis, questions specific to the WPC have been addressed which have been identified to require more detailed studies. Based on the outcome of this analysis, a safety analysis has been made which comprises of the modeling and calculation of radionuclide transport from the repository to the biosphere and the resulting dose exposure to man. The result of the safety analysis indicates that the present design of a WPC repository may give unacceptably high doses. By improving the properties of the bentonite/sand barrier such that the hydraulic conductivity is reduced, or by changing the short-lived steel canisters to more long-lived canisters, e.g. copper canisters, it is judged possible to achieve a sufficiently low level of dose exposure rates to man. The cost for a WPC repository of the studied design is significantly higher than for a KBS-3 repository considering the Swedish conditions and the Swedish amount of spent fuel. The major costs are connected to the excavation and backfilling of the bentonite/sand barrier. The potential for cost savings is high but it is not judged possible to account for savings in such a way that the WPC concept shows lower cost than the KBS-3 concept. (34 figs., 33 tabs., 29 refs.)

  6. High-Performance Integrated Virtual Environment (HIVE) Tools and Applications for Big Data Analysis.

    Science.gov (United States)

    Simonyan, Vahan; Mazumder, Raja

    2014-09-30

    The High-performance Integrated Virtual Environment (HIVE) is a high-throughput cloud-based infrastructure developed for the storage and analysis of genomic and associated biological data. HIVE consists of a web-accessible interface for authorized users to deposit, retrieve, share, annotate, compute and visualize Next-generation Sequencing (NGS) data in a scalable and highly efficient fashion. The platform contains a distributed storage library and a distributed computational powerhouse linked seamlessly. Resources available through the interface include algorithms, tools and applications developed exclusively for the HIVE platform, as well as commonly used external tools adapted to operate within the parallel architecture of the system. HIVE is composed of a flexible infrastructure, which allows for simple implementation of new algorithms and tools. Currently, available HIVE tools include sequence alignment and nucleotide variation profiling tools, metagenomic analyzers, phylogenetic tree-building tools using NGS data, clone discovery algorithms, and recombination analysis algorithms. In addition to tools, HIVE also provides knowledgebases that can be used in conjunction with the tools for NGS sequence and metadata analysis.

  7. High-Performance Integrated Virtual Environment (HIVE Tools and Applications for Big Data Analysis

    Directory of Open Access Journals (Sweden)

    Vahan Simonyan

    2014-09-01

    Full Text Available The High-performance Integrated Virtual Environment (HIVE is a high-throughput cloud-based infrastructure developed for the storage and analysis of genomic and associated biological data. HIVE consists of a web-accessible interface for authorized users to deposit, retrieve, share, annotate, compute and visualize Next-generation Sequencing (NGS data in a scalable and highly efficient fashion. The platform contains a distributed storage library and a distributed computational powerhouse linked seamlessly. Resources available through the interface include algorithms, tools and applications developed exclusively for the HIVE platform, as well as commonly used external tools adapted to operate within the parallel architecture of the system. HIVE is composed of a flexible infrastructure, which allows for simple implementation of new algorithms and tools. Currently, available HIVE tools include sequence alignment and nucleotide variation profiling tools, metagenomic analyzers, phylogenetic tree-building tools using NGS data, clone discovery algorithms, and recombination analysis algorithms. In addition to tools, HIVE also provides knowledgebases that can be used in conjunction with the tools for NGS sequence and metadata analysis.

  8. Error-rate performance analysis of incremental decode-and-forward opportunistic relaying

    KAUST Repository

    Tourki, Kamel; Yang, Hongchuan; Alouini, Mohamed-Slim

    2011-01-01

    In this paper, we investigate an incremental opportunistic relaying scheme where the selected relay chooses to cooperate only if the source-destination channel is of an unacceptable quality. In our study, we consider regenerative relaying in which the decision to cooperate is based on a signal-to-noise ratio (SNR) threshold and takes into account the effect of the possible erroneously detected and transmitted data at the best relay. We derive a closed-form expression for the end-to-end bit-error rate (BER) of binary phase-shift keying (BPSK) modulation based on the exact probability density function (PDF) of each hop. Furthermore, we evaluate the asymptotic error performance and the diversity order is deduced. We show that performance simulation results coincide with our analytical results. © 2011 IEEE.

  9. Error-rate performance analysis of incremental decode-and-forward opportunistic relaying

    KAUST Repository

    Tourki, Kamel

    2010-10-01

    In this paper, we investigate an incremental opportunistic relaying scheme where the selected relay chooses to cooperate only if the source-destination channel is of an unacceptable quality. In our study, we consider regenerative relaying in which the decision to cooperate is based on a signal-to-noise ratio (SNR) threshold and takes into account the effect of the possible erroneously detected and transmitted data at the best relay. We derive a closed-form expression for the end-to-end biterror rate (BER) of binary phase-shift keying (BPSK) modulation based on the exact probability density function (PDF) of each hop. Furthermore, we evaluate the asymptotic error performance and the diversity order is deduced. We show that performance simulation results coincide with our analytical results. ©2010 IEEE.

  10. Error-rate performance analysis of incremental decode-and-forward opportunistic relaying

    KAUST Repository

    Tourki, Kamel; Yang, Hongchuan; Alouini, Mohamed-Slim

    2010-01-01

    In this paper, we investigate an incremental opportunistic relaying scheme where the selected relay chooses to cooperate only if the source-destination channel is of an unacceptable quality. In our study, we consider regenerative relaying in which the decision to cooperate is based on a signal-to-noise ratio (SNR) threshold and takes into account the effect of the possible erroneously detected and transmitted data at the best relay. We derive a closed-form expression for the end-to-end biterror rate (BER) of binary phase-shift keying (BPSK) modulation based on the exact probability density function (PDF) of each hop. Furthermore, we evaluate the asymptotic error performance and the diversity order is deduced. We show that performance simulation results coincide with our analytical results. ©2010 IEEE.

  11. Error-rate performance analysis of incremental decode-and-forward opportunistic relaying

    KAUST Repository

    Tourki, Kamel

    2011-06-01

    In this paper, we investigate an incremental opportunistic relaying scheme where the selected relay chooses to cooperate only if the source-destination channel is of an unacceptable quality. In our study, we consider regenerative relaying in which the decision to cooperate is based on a signal-to-noise ratio (SNR) threshold and takes into account the effect of the possible erroneously detected and transmitted data at the best relay. We derive a closed-form expression for the end-to-end bit-error rate (BER) of binary phase-shift keying (BPSK) modulation based on the exact probability density function (PDF) of each hop. Furthermore, we evaluate the asymptotic error performance and the diversity order is deduced. We show that performance simulation results coincide with our analytical results. © 2011 IEEE.

  12. High-dose-rate versus low-dose-rate brachytherapy in the treatment of cervical cancer: analysis of tumor recurrence - the University of Wisconsin experience

    International Nuclear Information System (INIS)

    Petereit, Daniel G.; Sarkaria, Jann N.; Potter, David M.; Schink, Julian C.

    1999-01-01

    Purpose: To retrospectively compare the clinical outcome for cervical cancer patients treated with high-dose-rate (HDR) vs. low-dose-rate (LDR) brachytherapy. Methods and Materials: One hundred ninety-one LDR patients were treated from 1977 to 1988 and compared to 173 HDR patients treated from 1989 to 1996. Patients of similar stage and tumor volumes were treated with identical external beam fractionation schedules. Brachytherapy was given in either 1 or 2 LDR implants for the earlier patient cohort, and 5 HDR implants for the latter cohort. For both patient groups, Point A received a minimum total dose of 80 Gy. The linear-quadratic formula was used to calculate the LDR dose-equivalent contribution to Point A for the HDR treatments. The primary endpoints assessed were survival, pelvic control, relapse-free survival, and distant metastases. Endpoints were estimated using the Kaplan-Meier method. Comparisons between treatment groups were performed using the log-rank test and Cox proportional hazards models. Results: The median follow-up was 65 months (2 to 208 months) in the LDR group and 22 months (1 to 85 months) in the HDR group. For all stages combined there was no difference in survival, pelvic control, relapse-free survival, or distant metastases between LDR and HDR patients. For Stage IB and II HDR patients, the pelvic control rates were 85% and 80% with survival rates of 86% and 65% at 3 years, respectively. In the LDR group, Stage IB and II patients had 91% and 78% pelvic control rates, with 82% and 58% survival rates at 3 years, respectively. No difference was seen in survival or pelvic control for bulky Stage I and II patients combined (> 5 cm). Pelvic control at 3 years was 44% (HDR) versus 75% (LDR) for Stage IIIB patients (p = 0.002). This difference in pelvic control was associated with a lower survival rate in the Stage IIIB HDR versus LDR population (33% versus 58%, p = 0.004). The only major difference, with regard to patient characteristics

  13. Analysis of scalability of high-performance 3D image processing platform for virtual colonoscopy.

    Science.gov (United States)

    Yoshida, Hiroyuki; Wu, Yin; Cai, Wenli

    2014-03-19

    One of the key challenges in three-dimensional (3D) medical imaging is to enable the fast turn-around time, which is often required for interactive or real-time response. This inevitably requires not only high computational power but also high memory bandwidth due to the massive amount of data that need to be processed. For this purpose, we previously developed a software platform for high-performance 3D medical image processing, called HPC 3D-MIP platform, which employs increasingly available and affordable commodity computing systems such as the multicore, cluster, and cloud computing systems. To achieve scalable high-performance computing, the platform employed size-adaptive, distributable block volumes as a core data structure for efficient parallelization of a wide range of 3D-MIP algorithms, supported task scheduling for efficient load distribution and balancing, and consisted of a layered parallel software libraries that allow image processing applications to share the common functionalities. We evaluated the performance of the HPC 3D-MIP platform by applying it to computationally intensive processes in virtual colonoscopy. Experimental results showed a 12-fold performance improvement on a workstation with 12-core CPUs over the original sequential implementation of the processes, indicating the efficiency of the platform. Analysis of performance scalability based on the Amdahl's law for symmetric multicore chips showed the potential of a high performance scalability of the HPC 3D-MIP platform when a larger number of cores is available.

  14. A Longitudinal Examination of Rater and Ratee Effects in Performance Ratings.

    Science.gov (United States)

    Vance, Robert J.; And Others

    1983-01-01

    Investigated the consistency and loci of leniency, halo, and range restriction effects in performance ratings in a longitudinal study. Policy supervisors (N=90) rated 350 subordinates on five occasions. Concluded that reliable variance in mean ratings is partly attributable to ratees, but mainly introduced by raters. (JAC)

  15. Clojure high performance programming

    CERN Document Server

    Kumar, Shantanu

    2013-01-01

    This is a short, practical guide that will teach you everything you need to know to start writing high performance Clojure code.This book is ideal for intermediate Clojure developers who are looking to get a good grip on how to achieve optimum performance. You should already have some experience with Clojure and it would help if you already know a little bit of Java. Knowledge of performance analysis and engineering is not required. For hands-on practice, you should have access to Clojure REPL with Leiningen.

  16. High-performance liquid chromatography coupled with tandem mass spectrometry technology in the analysis of Chinese Medicine Formulas: A bibliometric analysis (1997-2015).

    Science.gov (United States)

    He, Xi-Ran; Li, Chun-Guang; Zhu, Xiao-Shu; Li, Yuan-Qing; Jarouche, Mariam; Bensoussan, Alan; Li, Ping-Ping

    2017-01-01

    There is a recognized challenge in analyzing traditional Chinese medicine formulas because of their complex chemical compositions. The application of modern analytical techniques such as high-performance liquid chromatography coupled with a tandem mass spectrometry has improved the characterization of various compounds from traditional Chinese medicine formulas significantly. This study aims to conduct a bibliometric analysis to recognize the overall trend of high-performance liquid chromatography coupled with tandem mass spectrometry approaches in the analysis of traditional Chinese medicine formulas, its significance and possible underlying interactions between individual herbs in these formulas. Electronic databases were searched systematically, and the identified studies were collected and analyzed using Microsoft Access 2010, Graph Pad 5.0 software and Ucinet software package. 338 publications between 1997 and 2015 were identified, and analyzed in terms of annual growth and accumulated publications, top journals, forms of traditional Chinese medicine preparations and highly studied formulas and single herbs, as well as social network analysis of single herbs. There is a significant increase trend in using high-performance liquid chromatography coupled with tandem mass spectrometry related techniques in analysis of commonly used forms of traditional Chinese medicine formulas in the last 3 years. Stringent quality control is of great significance for the modernization and globalization of traditional Chinese medicine, and this bibliometric analysis provided the first and comprehensive summary within this field. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. High population increase rates.

    Science.gov (United States)

    1991-09-01

    In addition to its economic and ethnic difficulties, the USSR faces several pressing demographic problems, including high population increase rates in several of its constituent republics. It has now become clear that although the country's rigid centralized planning succeeded in covering the basic needs of people, it did not lead to welfare growth. Since the 1970s, the Soviet economy has remained sluggish, which as led to increase in the death and birth rates. Furthermore, the ideology that held that demography could be entirely controlled by the country's political and economic system is contradicted by current Soviet reality, which shows that religion and ethnicity also play a significant role in demographic dynamics. Currently, Soviet republics fall under 2 categories--areas with high or low natural population increase rates. Republics with low rates consist of Christian populations (Armenia, Moldavia, Georgia, Byelorussia, Russia, Lithuania, Estonia, Latvia, Ukraine), while republics with high rates are Muslim (Tadzhikistan, Uzbekistan, Turkmenistan, Kirgizia, Azerbaijan Kazakhstan). The later group has natural increase rates as high as 3.3%. Although the USSR as a whole is not considered a developing country, the later group of republics fit the description of the UNFPA's priority list. Another serious demographic issue facing the USSR is its extremely high rate of abortion. This is especially true in the republics of low birth rates, where up to 60% of all pregnancies are terminated by induced abortions. Up to 1/5 of the USSR's annual health care budget is spent on clinical abortions -- money which could be better spent on the production of contraceptives. Along with the recent political and economic changes, the USSR is now eager to deal with its demographic problems.

  18. Electronics for very high rate tracking detectors

    International Nuclear Information System (INIS)

    Williams, H.H.; Dressnandt, N.; Ekenberg, T.; Gerds, E.J.; Newcomer, F.M.; Tedja, S.; Van Berg, R.; Van der Speigel, J.

    1995-01-01

    Results are presented on a system of electronics designed for very high rate tracking detectors at the SSC and LHC. The primary goal was a system for signal detection, time measurement, and readout for the straw tracker for SDC. An integrated circuit incorporating eight channels of amplifier-shaper-discriminator (including detector tail cancellation), and two different integrated circuits for time measurement are described. The performance of tracking measurements up to counting rates of 8 MHz per wire is reported, as well as preliminary results from a baseline restoration circuit. (orig.)

  19. Mammographic image reject rate analysis and cause – A National Maltese Study

    International Nuclear Information System (INIS)

    Mercieca, N.; Portelli, J.L.; Jadva-Patel, H.

    2017-01-01

    Mammography is used as a first-line investigation in the detection of breast cancer and imaging is required to be of optimal quality and achieved without adverse effects on the health of individuals. Repeated images come at a cost in terms of radiation dose, discomfort to clients and unnecessary financial burdens. No studies investigating mammography quality in Malta had been previously undertaken. Hence, this research aimed to investigate whether mammography is being performed at an acceptable level, through the investigation of reject rates. Quantitative methodology was used to collect data from eight participating mammography units, which were utilising screen film (SFM), computed radiography (CR) and direct digital mammography (DDM). Data relating to the total number of images performed, rejects and causes was prospectively collected over two weeks, resulting in a sample of 2291 images. All units were also asked to answer a questionnaire which provided other data that could be used for analysis. The national mammography reject rate was found to be 2.62%; within the 3% acceptable range. Individual rates' analysis revealed unacceptably high or low reject rates in some units. Positioning was the main reject cause. No significant difference in rejection was found between different types of mammography units or radiographers' experience. Alternatively, radiographers' qualifications, employment conditions and use of rejection criteria were proven to affect reject rates. Whilst on a national level, images are being rejected at an acceptable rate, individual units revealed suboptimal rates; at the cost of extra radiation, added discomfort and financial burden. - Highlights: • The national reject rate complied with the European Guidelines. • Reject rates in different units were found to vary. • Positioning was the commonest cause for repeats. • The equipment used and radiographers' experience did not affect reject rates. • Qualifications

  20. An alginic acid assisted rheological phase synthesis of carbon coated Li{sub 3}V{sub 2}(PO{sub 4}){sub 3} with high-rate performance

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Yue, E-mail: tju_wuyue@163.com [Department of Applied Chemistry, School of Chemical and Engineering, Tianjin University, Tianjin 300072 (China); Tang, Zhiyuan [Department of Applied Chemistry, School of Chemical and Engineering, Tianjin University, Tianjin 300072 (China); Guo, Xuyun [Department of Chemistry, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong Special Administrative Region (Hong Kong); Du, Chenqiang [Department of Applied Chemistry, School of Chemical and Engineering, Tianjin University, Tianjin 300072 (China); Zhang, Xinhe [McNair Technology Co., Ltd., Dongguan, Guangdong 523700 (China)

    2014-12-15

    Highlights: • Li{sub 3}V{sub 2}(PO{sub 4}){sub 3}/C sample was prepared by a modified rheological phase reaction method. • Alginic acid was firstly used as a promising carbon source and investigated. • LVP/C exhibits excellent rate and cycling performances in different voltage ranges. • LVP/C delivers the largest discharge capacity of 61.4 mAh g{sup −1} at 90 C rate in 3.0–4.3 V. • LVP/C can cycle 400 times with slight capacity fading at 20 C high rate in 3.0–4.8 V. - Abstract: A nanoscaled Li{sub 3}V{sub 2}(PO{sub 4}){sub 3}/C(LVP/C) composite is successfully synthesized via a modified rheological phase method. Alginic acid is applied as a new carbon source and ethylene glycol is used as the dispersant, and both of which play multifaceted roles during the synthetic route. A series of intensive investigations shows that the LVP/C composite possesses a three-dimensional carbon network and a loose structure, which provide discontinuous electronic and ionic pathways. The electrochemical performance of the LVP/C cathode is revealed to be impressive in terms of capacity, high-rate capability and long-life cycleability. Between 3.0 and 4.3 V, it delivers a discharge capacity of 132.3 mAh g{sup −1} at 0.5 C rate, approaching the theoretical value, and can cycle at a rate as high as 40 C without obvious capacity fading. Most distinctively, when discharged at 90 C ultrahigh rate (charged at 5 C rate), the largest capacity of 61.4 mAh g{sup −1} can still be available, after 600 cycles the capacity retention can still maintain 76%. When operated within 3.0–4.8 V, it cannot only discharge the initial capacity of 184.1 mAh g{sup −1} at 0.1 C, but also exhibit a stable cycling performance at 20 C for 400 cycles. These excellent performances can be fundamentally attributed to the high electronic/ionic conductivities which are related closely to the modified rheological phase preparation route and the promising new carbon source.

  1. PetIGA: A framework for high-performance isogeometric analysis

    KAUST Repository

    Dalcin, Lisandro; Collier, N.; Vignal, Philippe; Cortes, Adriano Mauricio; Calo, Victor M.

    2016-01-01

    We present PetIGA, a code framework to approximate the solution of partial differential equations using isogeometric analysis. PetIGA can be used to assemble matrices and vectors which come from a Galerkin weak form, discretized with Non-Uniform Rational B-spline basis functions. We base our framework on PETSc, a high-performance library for the scalable solution of partial differential equations, which simplifies the development of large-scale scientific codes, provides a rich environment for prototyping, and separates parallelism from algorithm choice. We describe the implementation of PetIGA, and exemplify its use by solving a model nonlinear problem. To illustrate the robustness and flexibility of PetIGA, we solve some challenging nonlinear partial differential equations that include problems in both solid and fluid mechanics. We show strong scaling results on up to 40964096 cores, which confirm the suitability of PetIGA for large scale simulations.

  2. PetIGA: A framework for high-performance isogeometric analysis

    KAUST Repository

    Dalcin, L.

    2016-05-25

    We present PetIGA, a code framework to approximate the solution of partial differential equations using isogeometric analysis. PetIGA can be used to assemble matrices and vectors which come from a Galerkin weak form, discretized with Non-Uniform Rational B-spline basis functions. We base our framework on PETSc, a high-performance library for the scalable solution of partial differential equations, which simplifies the development of large-scale scientific codes, provides a rich environment for prototyping, and separates parallelism from algorithm choice. We describe the implementation of PetIGA, and exemplify its use by solving a model nonlinear problem. To illustrate the robustness and flexibility of PetIGA, we solve some challenging nonlinear partial differential equations that include problems in both solid and fluid mechanics. We show strong scaling results on up to 40964096 cores, which confirm the suitability of PetIGA for large scale simulations.

  3. Mathematical modeling of high-rate Anammox UASB reactor based on granular packing patterns

    International Nuclear Information System (INIS)

    Tang, Chong-Jian; He, Rui; Zheng, Ping; Chai, Li-Yuan; Min, Xiao-Bo

    2013-01-01

    Highlights: ► A novel model was conducted to estimate volumetric nitrogen conversion rates. ► The packing patterns of the granules in Anammox reactor are investigated. ► The simple cubic packing pattern was simulated in high-rate Anammox UASB reactor. ► Operational strategies concerning sludge concentration were proposed by the modeling. -- Abstract: A novel mathematical model was developed to estimate the volumetric nitrogen conversion rates of a high-rate Anammox UASB reactor based on the packing patterns of granular sludge. A series of relationships among granular packing density, sludge concentration, hydraulic retention time and volumetric conversion rate were constructed to correlate Anammox reactor performance with granular packing patterns. It was suggested that the Anammox granules packed as the equivalent simple cubic pattern in high-rate UASB reactor with packing density of 50–55%, which not only accommodated a high concentration of sludge inside the reactor, but also provided large pore volume, thus prolonging the actual substrate conversion time. Results also indicated that it was necessary to improve Anammox reactor performance by enhancing substrate loading when sludge concentration was higher than 37.8 gVSS/L. The established model was carefully calibrated and verified, and it well simulated the performance of granule-based high-rate Anammox UASB reactor

  4. Mathematical modeling of high-rate Anammox UASB reactor based on granular packing patterns

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chong-Jian, E-mail: chjtangzju@yahoo.com.cn [Department of Environmental Engineering, School of Metallurgical Science and Engineering, Central South University, Changsha 410083 (China); National Engineering Research Center for Control and Treatment of Heavy Metal Pollution, Changsha 410083 (China); He, Rui; Zheng, Ping [Department of Environmental Engineering, Zhejiang University, Zijingang Campus, Hangzhou 310058 (China); Chai, Li-Yuan; Min, Xiao-Bo [Department of Environmental Engineering, School of Metallurgical Science and Engineering, Central South University, Changsha 410083 (China); National Engineering Research Center for Control and Treatment of Heavy Metal Pollution, Changsha 410083 (China)

    2013-04-15

    Highlights: ► A novel model was conducted to estimate volumetric nitrogen conversion rates. ► The packing patterns of the granules in Anammox reactor are investigated. ► The simple cubic packing pattern was simulated in high-rate Anammox UASB reactor. ► Operational strategies concerning sludge concentration were proposed by the modeling. -- Abstract: A novel mathematical model was developed to estimate the volumetric nitrogen conversion rates of a high-rate Anammox UASB reactor based on the packing patterns of granular sludge. A series of relationships among granular packing density, sludge concentration, hydraulic retention time and volumetric conversion rate were constructed to correlate Anammox reactor performance with granular packing patterns. It was suggested that the Anammox granules packed as the equivalent simple cubic pattern in high-rate UASB reactor with packing density of 50–55%, which not only accommodated a high concentration of sludge inside the reactor, but also provided large pore volume, thus prolonging the actual substrate conversion time. Results also indicated that it was necessary to improve Anammox reactor performance by enhancing substrate loading when sludge concentration was higher than 37.8 gVSS/L. The established model was carefully calibrated and verified, and it well simulated the performance of granule-based high-rate Anammox UASB reactor.

  5. Predicting Performance Ratings Using Motivational Antecedents

    National Research Council Canada - National Science Library

    Zazania, Michelle

    1998-01-01

    This research examined the role of motivation in predicting peer and trainer ratings of student performance and contrasted the relative importance of various antecedents for peer and trainer ratings...

  6. Analysis of speed, stroke rate, and stroke distance for world-class breaststroke swimming.

    Science.gov (United States)

    Garland Fritzdorf, Stephen; Hibbs, Angela; Kleshnev, Valery

    2009-02-15

    Speed in aquatic locomotion is determined by stroke distance and stroke rate, but it does not always follow that an increase in stroke rate will lead to an increase in speed. Kleshnev (2006) developed a method to evaluate the relationship between speed and stroke rate during rowing - the effective work per stroke. In this case study, the effective work per stroke was determined for a male world-class 100-m breaststroke swimmer for seven races in major championships and compared between: each of the seven races; each quarter within each race; and the best swims of this case study and seven other world-class swimmers. The effective work per stroke was related to race performance, with the fastest race having the highest effective work per stroke and lowest stroke rate, with slower races having low effectiveness and high stroke rate (R(2) = 0.85). The effective work per stroke was reduced in a race as the swimmer fatigued. The within-race standard deviation of effectiveness was lower in fast swims (R(2) = 0.84). This analysis has identified some characteristics of fast swimming: high effectiveness, optimal stroke rate, and a flat effectiveness profile. Training and racing strategies can now be devised to improve performance by increasing the sensitivity of assessment of strengths and weaknesses in individuals.

  7. Review of recycling performance indicators: a study on collection rate in Taiwan.

    Science.gov (United States)

    Wen, Lihchyi; Lin, Chun-Hsu; Lee, Soo-Cheol

    2009-08-01

    The Taiwan Environmental Protection Administration (Taiwan EPA) launched a national Extended Producer Responsibility (EPR) system after integrating eight private recycling organizations in 1998. After that, the environmental performance of the EPR system brought a lot of attention to policy makers. Many studies show positive environmental effects of the EPR system in Taiwan. However, there are controversial questions remained, such as whether the performance indicators used are the right choice to estimate the environmental effects of the recycling policy? Can those estimated results really reflect the performance of the system? This paper would therefore like to more accurately evaluate the performance indicators of the EPR system based on data observed over the past decade in Taiwan. In the process of evaluating the performance indicators, we have found that the collection rates for durable goods are often ignored in countries that pursue a zero waste policy. This may affect the actual recycling outcome and resource direction targeted by producers. However, in order for the collection rate to be adopted as a policy indicator, how to estimate the amounts of retired or waste products during a period is critical. In this paper, we estimate the collection rate for electrical and electronic waste by using the survival analysis and ownership data analysis approaches. We also provide a comparison of both approaches and put forward suggestions for directions in the future in solid waste management.

  8. Review of recycling performance indicators: A study on collection rate in Taiwan

    International Nuclear Information System (INIS)

    Wen Lihchyi; Lin Chunhsu; Lee, Soo-cheol

    2009-01-01

    The Taiwan Environmental Protection Administration (Taiwan EPA) launched a national Extended Producer Responsibility (EPR) system after integrating eight private recycling organizations in 1998. After that, the environmental performance of the EPR system brought a lot of attention to policy makers. Many studies show positive environmental effects of the EPR system in Taiwan. However, there are controversial questions remained, such as whether the performance indicators used are the right choice to estimate the environmental effects of the recycling policy? Can those estimated results really reflect the performance of the system? This paper would therefore like to more accurately evaluate the performance indicators of the EPR system based on data observed over the past decade in Taiwan. In the process of evaluating the performance indicators, we have found that the collection rates for durable goods are often ignored in countries that pursue a zero waste policy. This may affect the actual recycling outcome and resource direction targeted by producers. However, in order for the collection rate to be adopted as a policy indicator, how to estimate the amounts of retired or waste products during a period is critical. In this paper, we estimate the collection rate for electrical and electronic waste by using the survival analysis and ownership data analysis approaches. We also provide a comparison of both approaches and put forward suggestions for directions in the future in solid waste management.

  9. High strain rate behaviour of polypropylene microfoams

    Directory of Open Access Journals (Sweden)

    Martínez A.B.

    2012-08-01

    Full Text Available Microcellular materials such as polypropylene foams are often used in protective applications and passive safety for packaging (electronic components, aeronautical structures, food, etc. or personal safety (helmets, knee-pads, etc.. In such applications the foams which are used are often designed to absorb the maximum energy and are generally subjected to severe loadings involving high strain rates. The manufacture process to obtain polymeric microcellular foams is based on the polymer saturation with a supercritical gas, at high temperature and pressure. This method presents several advantages over the conventional injection moulding techniques which make it industrially feasible. However, the effect of processing conditions such as blowing agent, concentration and microfoaming time and/or temperature on the microstructure of the resulting microcellular polymer (density, cell size and geometry is not yet set up. The compressive mechanical behaviour of several microcellular polypropylene foams has been investigated over a wide range of strain rates (0.001 to 3000 s−1 in order to show the effects of the processing parameters and strain rate on the mechanical properties. High strain rate tests were performed using a Split Hopkinson Pressure Bar apparatus (SHPB. Polypropylene and polyethylene-ethylene block copolymer foams of various densities were considered.

  10. High-rate, High Temperature Acetotrophic Methanogenesis Governed by a Three Population Consortium in Anaerobic Bioreactors.

    Directory of Open Access Journals (Sweden)

    Dang Ho

    Full Text Available A combination of acetate oxidation and acetoclastic methanogenesis has been previously identified to enable high-rate methanogenesis at high temperatures (55 to 65°C, but this capability had not been linked to any key organisms. This study combined RNA-stable isotope probing on 13C-labelled acetate and 16S amplicon sequencing to identify the active micro-organisms involved in high-rate methanogenesis. Active biomass was harvested from three bench-scale thermophilic bioreactors treating waste activated sludge at 55, 60 and 65°C, and fed with 13-C labelled and 12C-unlabelled acetate. Acetate uptake and cumulative methane production were determined and kinetic parameters were estimated using model-based analysis. Pyrosequencing performed on 13C- enriched samples indicated that organisms accumulating labelled carbon were Coprothermobacter (all temperatures between 55 and 65°C, acetoclastic Methanosarcina (55 to 60°C and hydrogenotrophic Methanothermobacter (60 to 65°C. The increased relative abundance of Coprothermobacter with increased temperature corresponding with a shift to syntrophic acetate oxidation identified this as a potentially key oxidiser. Methanosarcina likely acts as both a hydrogen utilising and acetoclastic methanogen at 55°C, and is replaced by Methanothermobacter as a hydrogen utiliser at higher temperatures.

  11. High-rate, High Temperature Acetotrophic Methanogenesis Governed by a Three Population Consortium in Anaerobic Bioreactors.

    Science.gov (United States)

    Ho, Dang; Jensen, Paul; Gutierrez-Zamora, Maria-Luisa; Beckmann, Sabrina; Manefield, Mike; Batstone, Damien

    2016-01-01

    A combination of acetate oxidation and acetoclastic methanogenesis has been previously identified to enable high-rate methanogenesis at high temperatures (55 to 65°C), but this capability had not been linked to any key organisms. This study combined RNA-stable isotope probing on 13C-labelled acetate and 16S amplicon sequencing to identify the active micro-organisms involved in high-rate methanogenesis. Active biomass was harvested from three bench-scale thermophilic bioreactors treating waste activated sludge at 55, 60 and 65°C, and fed with 13-C labelled and 12C-unlabelled acetate. Acetate uptake and cumulative methane production were determined and kinetic parameters were estimated using model-based analysis. Pyrosequencing performed on 13C- enriched samples indicated that organisms accumulating labelled carbon were Coprothermobacter (all temperatures between 55 and 65°C), acetoclastic Methanosarcina (55 to 60°C) and hydrogenotrophic Methanothermobacter (60 to 65°C). The increased relative abundance of Coprothermobacter with increased temperature corresponding with a shift to syntrophic acetate oxidation identified this as a potentially key oxidiser. Methanosarcina likely acts as both a hydrogen utilising and acetoclastic methanogen at 55°C, and is replaced by Methanothermobacter as a hydrogen utiliser at higher temperatures.

  12. Mass composition analysis using elongation rate

    Energy Technology Data Exchange (ETDEWEB)

    Ochilo, Livingstone; Risse, Markus; Yushkov, Alexey [University of Siegen, Siegen (Germany)

    2015-07-01

    The all-particle cosmic ray energy spectrum has been observed to flatten at around 5.2 x 10{sup 18} eV where the spectral index changes from γ = 3.2 to γ = 2.6, a feature called the ''ankle'' of the spectrum. Cosmic rays with energy around the ankle and beyond, known as ultra-high energy cosmic rays (UHECR), have a very low flux and reconstruction of their properties from extensive air shower measurements is subject to uncertainties for instance from hadronic interaction models. Since the year 2004, the Pierre Auger Observatory has recorded a considerable number of UHECR events beyond the ankle. With the greatly improved statistics, the mass composition of the extreme end of the cosmic ray energy spectrum is now being investigated with improved accuracy. The measured composition of UHECR is an important parameter in validating the models used to explain their sources and acceleration mechanisms. In this study, we perform a mass composition analysis using elongation rate (the rate of change of the depth of shower maximum with energy), measured by the fluorescence detector of the Pierre Auger Observatory. The advantage of this approach is a weak dependence of the results on the choice of the hadronic interaction models.

  13. Noise performance in AlGaN/GaN HEMTs under high drain bias

    International Nuclear Information System (INIS)

    Pang Lei; Pu Yan; Lin Xinyu; Wang Liang; Liu Jian

    2009-01-01

    The advent of fully integrated GaN PA-LNA circuits makes it meaningful to investigate the noise performance under high drain bias. However, noise performance of AlGaN/GaN HEMTs under high bias has not received worldwide attention in theoretical studies due to its complicated mechanisms. The noise value is moderately higher and its rate of increase is fast with increasing high voltage. In this paper, several possible mechanisms are proposed to be responsible for it. Impact ionization under high electric field incurs great fluctuation of carrier density, which increases the drain diffusion noise. Besides, higher gate leakage current related shot noise and a more severe self-heating effect are also contributors to the noise increase at high bias. Analysis from macroscopic and microscopic perspectives can help us to design new device structures to improve noise performance of AlGaN/GaN HEMTs under high bias. (semiconductor devices)

  14. High-frame-rate digital radiographic videography

    Science.gov (United States)

    King, Nicholas S. P.; Cverna, Frank H.; Albright, Kevin L.; Jaramillo, Steven A.; Yates, George J.; McDonald, Thomas E.; Flynn, Michael J.; Tashman, Scott

    1994-10-01

    High speed x-ray imaging can be an important tool for observing internal processes in a wide range of applications. In this paper we describe preliminary implementation of a system having the eventual goal of observing the internal dynamics of bone and joint reactions during loading. Two Los Alamos National Laboratory (LANL) gated and image intensified camera systems were used to record images from an x-ray image convertor tube to demonstrate the potential of high frame-rate digital radiographic videography in the analysis of bone and joint dynamics of the human body. Preliminary experiments were done at LANL to test the systems. Initial high frame-rate imaging (from 500 to 1000 frames/s) of a swinging pendulum mounted to the face of an X-ray image convertor tube demonstrated high contrast response and baseline sensitivity. The systems were then evaluated at the Motion Analysis Laboratory of Henry Ford Health Systems Bone and Joint Center. Imaging of a 9 inch acrylic disk with embedded lead markers rotating at approximately 1000 RPM, demonstrated the system response to a high velocity/high contrast target. By gating the P-20 phosphor image from the X-ray image convertor with a second image intensifier (II) and using a 100 microsecond wide optical gate through the second II, enough prompt light decay from the x-ray image convertor phosphor had taken place to achieve reduction of most of the motion blurring. Measurement of the marker velocity was made by using video frames acquired at 500 frames/s. The data obtained from both experiments successfully demonstrated the feasibility of the technique. Several key areas for improvement are discussed along with salient test results and experiment details.

  15. Engineering-Based Problem Solving Strategies in AP Calculus: An Investigation into High School Student Performance on Related Rate Free-Response Problems

    Science.gov (United States)

    Thieken, John

    2012-01-01

    A sample of 127 high school Advanced Placement (AP) Calculus students from two schools was utilized to study the effects of an engineering design-based problem solving strategy on student performance with AP style Related Rate questions and changes in conceptions, beliefs, and influences. The research design followed a treatment-control multiple…

  16. Expressed microRNA associated with high rate of egg production in chicken ovarian follicles.

    Science.gov (United States)

    Wu, N; Gaur, U; Zhu, Q; Chen, B; Xu, Z; Zhao, X; Yang, M; Li, D

    2017-04-01

    MicroRNA (miRNA) is a highly conserved class of small noncoding RNA about 19-24 nucleotides in length that function in a specific manner to post-transcriptionally regulate gene expression in organisms. Tissue miRNA expression studies have discovered a myriad of functions for miRNAs in various aspects, but a role for miRNAs in chicken ovarian tissue at 300 days of age has not hitherto been reported. In this study, we performed the first miRNA analysis of ovarian tissues in chickens with low and high rates of egg production using high-throughput sequencing. By comparing low rate of egg production chickens with high rate of egg production chickens, 17 significantly differentially expressed miRNAs were found (P chickens with high rates of egg production, suggesting that these miRNAs have an important role in ovary development and reproductive management of chicken. Furthermore, we uncovered that a significantly up-regulated miRNA-gga-miR-200a-3p-is ubiquitous in reproduction-regulation-related pathways. This miRNA may play a special central role in the reproductive management of chicken, and needs to be further studied for confirmation. © 2016 Stichting International Foundation for Animal Genetics.

  17. High Heating Rates Affect Greatly the Inactivation Rate of Escherichia coli

    Science.gov (United States)

    Huertas, Juan-Pablo; Aznar, Arantxa; Esnoz, Arturo; Fernández, Pablo S.; Iguaz, Asunción; Periago, Paula M.; Palop, Alfredo

    2016-01-01

    Heat resistance of microorganisms can be affected by different influencing factors. Although, the effect of heating rates has been scarcely explored by the scientific community, recent researches have unraveled its important effect on the thermal resistance of different species of vegetative bacteria. Typically heating rates described in the literature ranged from 1 to 20°C/min but the impact of much higher heating rates is unclear. The aim of this research was to explore the effect of different heating rates, such as those currently achieved in the heat exchangers used in the food industry, on the heat resistance of Escherichia coli. A pilot plant tubular heat exchanger and a thermoresistometer Mastia were used for this purpose. Results showed that fast heating rates had a deep impact on the thermal resistance of E. coli. Heating rates between 20 and 50°C/min were achieved in the heat exchanger, which were much slower than those around 20°C/s achieved in the thermoresistometer. In all cases, these high heating rates led to higher inactivation than expected: in the heat exchanger, for all the experiments performed, when the observed inactivation had reached about seven log cycles, the predictions estimated about 1 log cycle of inactivation; in the thermoresistometer these differences between observed and predicted values were even more than 10 times higher, from 4.07 log cycles observed to 0.34 predicted at a flow rate of 70 mL/min and a maximum heating rate of 14.7°C/s. A quantification of the impact of the heating rates on the level of inactivation achieved was established. These results point out the important effect that the heating rate has on the thermal resistance of E. coli, with high heating rates resulting in an additional sensitization to heat and therefore an effective food safety strategy in terms of food processing. PMID:27563300

  18. An analysis of acute complications and perioperative morbidity from high dose rate brachytherapy in the treatment of gynecological malignancies

    International Nuclear Information System (INIS)

    Sarkaria, Jann N.; Petereit, Daniel G.; Kinsella, Timothy J.; Buchler, Dolores A.

    1995-01-01

    Purpose: To evaluate the acute morbidity and mortality for high dose-rate (HDR) brachytherapy performed in an outpatient setting in the treatment of gynecological malignancies, and to identify possible risk factors for adverse outcomes. Materials and Methods: One hundred seventy-one patients with cervical (n=129) or uterine (n=42) carcinoma with an intact uterus were evaluated and treated from August 1989 through December 1994, with at least part of their therapy delivered with intracavitary HDR 192 Ir radiation. A total of 830 ICR insertions were performed with greater than 95% done on an outpatient basis under heavy intravenous sedation using fentanyl and midazolam. Perioperative morbidity and mortality were recorded for any event occurring within 30 days of the completion of therapy. Anesthesia risk was evaluated retrospectively in all patients based on the American Society of Anesthesiologists' (ASA) Physical Class System. Results: The uterine patients, many treated with radiation alone because of morbid obesity or medical inoperability, had a significantly higher perioperative morbidity and mortality rate as compared to the cervix patient cohort. Thirteen of the 42 (31%) uterine patients and 8 of the 129 (6%) cervix patients required hospitalization within 30 days of treatment completion (p 2) experienced greater morbidity and mortality, while the best predictor of complications in the cervix patients was age greater than 70 years. For the entire cohort of patients, no correlation was found between the 30 day morbidity and mortality and the doses of fentanyl and midazolam used or the length of the procedure. Conclusions: The acute complication rate from HDR brachytherapy performed on an outpatient basis with heavy intravenous sedation is acceptable for the great majority of patients who present for treatment. However, the high morbidity and mortality experienced by certain patient cohorts suggests that careful assessment of the risk/benefit ratio for treatment

  19. Selection of High Performance Alloy for Gas Turbine Blade Using Multiphysics Analysis

    Directory of Open Access Journals (Sweden)

    H Khawaja

    2016-09-01

    Full Text Available With the extensive increase in the utilization of energy resources in the modern era, the need of energy extraction from various resources has pronounced in recent years. Thus comprehensive efforts have been made around the globe in the technological development of turbo machines where means of energy extraction is energized fluids. This development led the aviation industry to power boost due to better performing engines. Meanwhile, the structural conformability requirements relative to the functional requirements have also increased with the advent of newer, better performing materials. Thus there is a need to study the material behavior and its usage with the idea of selecting the best possible material for its application. In this work a gas turbine blade of a small turbofan engine, where geometry and aerodynamic data was available, was analyzed for its structural behavior in the proposed mission envelope, where the engine turbine is subjected to high thermal, inertial and aerodynamic loads. Multiphysics Finite Element (FE linear stress analysis was carried out on the turbine blade. The results revealed the upper limit of Ultimate Tensile Strength (UTS for the blade. Based on the limiting factor, high performance alloys were selected from the literature. The two most recommended alloy categories for gas turbine blades are NIMONIC and INCONEL from where total of 21 types of INCONEL alloys and 12 of NIMONIC alloys, available on commercial bases, were analyzed individually to meet the structural requirements. After applying selection criteria, four alloys were finalized from NIMONIC and INCONEL alloys for further analysis. On the basis of stress-strain behavior of finalized alloys, the Multiphysics FE nonlinear stress analysis was then carried out for the selection of the individual alloy by imposing a restriction of Ultimate Factor of Safety (UFOS of 1.33 and yield strength. Final selection is made keeping in view other factors

  20. Multicast Performance Analysis for High-Speed Torus Networks

    National Research Council Canada - National Science Library

    Oral, S; George, A

    2002-01-01

    ... for unicast-based and path-based multicast communication on high-speed torus networks. Software-based multicast performance results of selected algorithms on a 16-node Scalable Coherent Interface (SCI) torus are given...

  1. High Humidity Aerodynamic Effects Study on Offshore Wind Turbine Airfoil/Blade Performance through CFD Analysis

    Directory of Open Access Journals (Sweden)

    Weipeng Yue

    2017-01-01

    Full Text Available Damp air with high humidity combined with foggy, rainy weather, and icing in winter weather often is found to cause turbine performance degradation, and it is more concerned with offshore wind farm development. To address and understand the high humidity effects on wind turbine performance, our study has been conducted with spread sheet analysis on damp air properties investigation for air density and viscosity; then CFD modeling study using Fluent was carried out on airfoil and blade aerodynamic performance effects due to water vapor partial pressure of mixing flow and water condensation around leading edge and trailing edge of airfoil. It is found that the high humidity effects with water vapor mixing flow and water condensation thin film around airfoil may have insignificant effect directly on airfoil/blade performance; however, the indirect effects such as blade contamination and icing due to the water condensation may have significant effects on turbine performance degradation. Also it is that found the foggy weather with microwater droplet (including rainy weather may cause higher drag that lead to turbine performance degradation. It is found that, at high temperature, the high humidity effect on air density cannot be ignored for annual energy production calculation. The blade contamination and icing phenomenon need to be further investigated in the next study.

  2. Enabling High-performance Interactive Geoscience Data Analysis Through Data Placement and Movement Optimization

    Science.gov (United States)

    Zhu, F.; Yu, H.; Rilee, M. L.; Kuo, K. S.; Yu, L.; Pan, Y.; Jiang, H.

    2017-12-01

    Since the establishment of data archive centers and the standardization of file formats, scientists are required to search metadata catalogs for data needed and download the data files to their local machines to carry out data analysis. This approach has facilitated data discovery and access for decades, but it inevitably leads to data transfer from data archive centers to scientists' computers through low-bandwidth Internet connections. Data transfer becomes a major performance bottleneck in such an approach. Combined with generally constrained local compute/storage resources, they limit the extent of scientists' studies and deprive them of timely outcomes. Thus, this conventional approach is not scalable with respect to both the volume and variety of geoscience data. A much more viable solution is to couple analysis and storage systems to minimize data transfer. In our study, we compare loosely coupled approaches (exemplified by Spark and Hadoop) and tightly coupled approaches (exemplified by parallel distributed database management systems, e.g., SciDB). In particular, we investigate the optimization of data placement and movement to effectively tackle the variety challenge, and boost the popularization of parallelization to address the volume challenge. Our goal is to enable high-performance interactive analysis for a good portion of geoscience data analysis exercise. We show that tightly coupled approaches can concentrate data traffic between local storage systems and compute units, and thereby optimizing bandwidth utilization to achieve a better throughput. Based on our observations, we develop a geoscience data analysis system that tightly couples analysis engines with storages, which has direct access to the detailed map of data partition locations. Through an innovation data partitioning and distribution scheme, our system has demonstrated scalable and interactive performance in real-world geoscience data analysis applications.

  3. High Rate Digital Demodulator ASIC

    Science.gov (United States)

    Ghuman, Parminder; Sheikh, Salman; Koubek, Steve; Hoy, Scott; Gray, Andrew

    1998-01-01

    The architecture of High Rate (600 Mega-bits per second) Digital Demodulator (HRDD) ASIC capable of demodulating BPSK and QPSK modulated data is presented in this paper. The advantages of all-digital processing include increased flexibility and reliability with reduced reproduction costs. Conventional serial digital processing would require high processing rates necessitating a hardware implementation in other than CMOS technology such as Gallium Arsenide (GaAs) which has high cost and power requirements. It is more desirable to use CMOS technology with its lower power requirements and higher gate density. However, digital demodulation of high data rates in CMOS requires parallel algorithms to process the sampled data at a rate lower than the data rate. The parallel processing algorithms described here were developed jointly by NASA's Goddard Space Flight Center (GSFC) and the Jet Propulsion Laboratory (JPL). The resulting all-digital receiver has the capability to demodulate BPSK, QPSK, OQPSK, and DQPSK at data rates in excess of 300 Mega-bits per second (Mbps) per channel. This paper will provide an overview of the parallel architecture and features of the HRDR ASIC. In addition, this paper will provide an over-view of the implementation of the hardware architectures used to create flexibility over conventional high rate analog or hybrid receivers. This flexibility includes a wide range of data rates, modulation schemes, and operating environments. In conclusion it will be shown how this high rate digital demodulator can be used with an off-the-shelf A/D and a flexible analog front end, both of which are numerically computer controlled, to produce a very flexible, low cost high rate digital receiver.

  4. Construction and performance of MEGAs low-mass, high-rate cylindrical MWPCs

    Science.gov (United States)

    Cooper, M. D.; Armijo, V.; Black, J. K.; Bolton, R. D.; Carius, S.; Espinoza, C.; Hart, G.; Hogan, G. E.; Gonzales, A.; Kroupa, M. A.; Mischke, R. E.; Sandoval, J.; Schilling, S.; Sena, J.; Suazo, G.; Whitehouse, D. A.; Wilkinson, C. A.; Stantz, K.; Szymanski, J. J.; Jui, C. C.; Gagliardi, C. A.; Tribble, R. E.; Tu, X.-L.; Fisk, R. J.; Koetke, D. D.; Manweiler, R. W.; Nord, P. M.; Stanislaus, S.; Piilonen, L. E.; Zhang, Y. D.

    A design for extremely low mass, high-resolution multiwire proportional chambers (MWPC) was achieved by the MEGA collaboration in its experiment to search for the lepton family number violating decay μ→eγ. To extend the present branching ratio limit by over an order of magnitude, these MWPCs were operated in high particle fluxes. They showed minimal effects of aging, and evidenced spatial and energy resolutions for the orbiting positrons from muon decay which were consistent with our design parameters. The unique features of these chambers, their assembly into the MEGA positron spectrometer, and their performance during the experiment are described in this paper.

  5. Leak rate analysis of the Westinghouse Reactor Coolant Pump

    International Nuclear Information System (INIS)

    Boardman, T.; Jeanmougin, N.; Lofaro, R.; Prevost, J.

    1985-07-01

    An independent analysis was performed by ETEC to determine what the seal leakage rates would be for the Westinghouse Reactor Coolant Pump (RCP) during a postulated station blackout resulting from loss of ac electric power. The object of the study was to determine leakage rates for the following conditions: Case 1: All three seals function. Case 2: No. 1 seal fails open while Nos. 2 and 3 seals function. Case 3: All three seals fail open. The ETEC analysis confirmed Westinghouse calculations on RCP seal performance for the conditions investigated. The leak rates predicted by ETEC were slightly lower than those predicted by Westinghouse for each of the three cases as summarized below. Case 1: ETEC predicted 19.6 gpm, Westinghouse predicted 21.1 gpm. Case 2: ETEC predicted 64.7 gpm, Westinghouse predicted 75.6 gpm. Case 3: ETEC predicted 422 gpm, Westinghouse predicted 480 gpm. 3 refs., 22 figs., 6 tabs

  6. A fuel performance analysis for a 450 MWth deep burn-high temperature reactor

    International Nuclear Information System (INIS)

    Kim, Young Min; Jo, Chang Keun; Jun, Ji Su; Cho, Moon Sung; Venneri, Francesco

    2011-01-01

    Highlights: → We have checked, through a fuel performance analysis, if a 450 MW th high temperature reactor was safe for the deep burn of a TRU fuel. → During a core heat-up event, the fuel temperature was below 1600 deg. C and the maximum gas pressure in the void of coated fuel particle was about 90 MPa. → At elevated temperatures of the accident event, the failure fraction of coated fuel particles resulted from the mechanical failure and the thermal decomposition of the SiC barrier was 3.30 x 10 -3 . - Abstract: A performance analysis for a 450 MW th deep burn-high temperature reactor (DB-HTR) fuel was performed using COPA, a fuel performance analysis code of Korea Atomic Energy Research Institute (KAERI). The code computes gas pressure buildup in the void volume of a tri-isotropic coated fuel particle (TRISO), temperature distribution in a DB-HTR fuel, thermo-mechanical stress in a coated fuel particle (CFP), failure fractions of a batch of CFPs, and fission product (FP) releases into the coolant. The 350 μm DB-HTR kernel is composed of 30% UO 2 + 70% (5% NpO 2 + 95% PuO 1.8 ) mixed with 0.6 moles of silicon carbide (SiC) per mole of heavy metal. The DB-HTR is operated at the constant temperature and power of 858 deg. C and 39.02 mW per CFP for 1395 effective full power days (EFPD) and is subjected to a core heat-up event for 250 h during which the maximum coolant temperature reaches 1548.70 deg. C. Within the normal operating temperature, the fuel showed good thermal and mechanical integrity. At elevated temperatures of the accident event, the failure fraction of CFPs resulted from the mechanical failure (MF) and the thermal decomposition (TD) of the SiC barrier is 3.30 x 10 -3 .

  7. Performance evaluation of two highly interconnected Data Center networks

    DEFF Research Database (Denmark)

    Andrus, Bogdan-Mihai; Mihai Poncea, Ovidiu; Vegas Olmos, Juan José

    2015-01-01

    In this paper we present the analysis of highly interconnected topologies like hypercube and torus and how they can be implemented in data centers in order to cope with the rapid increase and demands for performance of the internal traffic. By replicating the topologies and subjecting them...... to uniformly distributed traffic routed by shortest path algorithms, we are able to extract relevant statistics related to average throughput, latency and loss rate. A decrease in throughput per connection of only about 5% for the hypercube compared to 16% for the 3D torus was measured when the size...

  8. Performance concerns for high duty fuel cycle

    International Nuclear Information System (INIS)

    Esposito, V.J.; Gutierrez, J.E.

    1999-01-01

    One of the goals of the nuclear industry is to achieve economic performance such that nuclear power plants are competitive in a de-regulated market. The manner in which nuclear fuel is designed and operated lies at the heart of economic viability. In this sense reliability, operating flexibility and low costs are the three major requirements of the NPP today. The translation of these three requirements to the design is part of our work. The challenge today is to produce a fuel design which will operate with long operating cycles, high discharge burnup, power up-rating and while still maintaining all design and safety margins. European Fuel Group (EFG) understands that to achieve the required performance high duty/energy fuel designs are needed. The concerns for high duty design includes, among other items, core design methods, advanced Safety Analysis methodologies, performance models, advanced material and operational strategies. The operational aspects require the trade-off and evaluation of various parameters including coolant chemistry control, material corrosion, boiling duty, boron level impacts, etc. In this environment MAEF is the design that EFG is now offering based on ZIRLO alloy and a robust skeleton. This new design is able to achieve 70 GWd/tU and Lead Test Programs are being executed to demonstrate this capability. A number of performance issues which have been a concern with current designs have been resolved such as cladding corrosion and incomplete RCCA insertion (IRI). As the core duty becomes more aggressive other new issues need to be addressed such as Axial Offset Anomaly. These new issues are being addressed by combination of the new design in concert with advanced methodologies to meet the demanding needs of NPP. The ability and strategy to meet high duty core requirements, flexibility of operation and maintain acceptable balance of all technical issues is the discussion in this paper. (authors)

  9. Implementation of the Principal Component Analysis onto High-Performance Computer Facilities for Hyperspectral Dimensionality Reduction: Results and Comparisons

    Directory of Open Access Journals (Sweden)

    Ernestina Martel

    2018-06-01

    Full Text Available Dimensionality reduction represents a critical preprocessing step in order to increase the efficiency and the performance of many hyperspectral imaging algorithms. However, dimensionality reduction algorithms, such as the Principal Component Analysis (PCA, suffer from their computationally demanding nature, becoming advisable for their implementation onto high-performance computer architectures for applications under strict latency constraints. This work presents the implementation of the PCA algorithm onto two different high-performance devices, namely, an NVIDIA Graphics Processing Unit (GPU and a Kalray manycore, uncovering a highly valuable set of tips and tricks in order to take full advantage of the inherent parallelism of these high-performance computing platforms, and hence, reducing the time that is required to process a given hyperspectral image. Moreover, the achieved results obtained with different hyperspectral images have been compared with the ones that were obtained with a field programmable gate array (FPGA-based implementation of the PCA algorithm that has been recently published, providing, for the first time in the literature, a comprehensive analysis in order to highlight the pros and cons of each option.

  10. Stretching of red blood cells at high strain rates

    Science.gov (United States)

    Mancuso, J. E.; Ristenpart, W. D.

    2017-10-01

    Most work on the mechanical behavior of red blood cells (RBCs) in flow has focused on simple shear flows. Relatively little work has examined RBC deformations in the physiologically important extensional flow that occurs at the entrance to a constriction. In particular, previous work suggests that RBCs rapidly stretch out and then retract upon entering the constriction, but to date no model predicts this behavior for the extremely high strain rates typically experienced there. In this Rapid Communication, we use high speed video to perform systematic measurements of the dynamic stretching behavior of RBCs as they enter a microfluidic constriction. We demonstrate that both the Kelvin-Voigt and Skalak viscoelastic models capture the observed stretching dynamics, up to strain rates as high as 2000 s-1. The results indicate that the effective elastic modulus of the RBC membrane at these strain rates is an order of magnitude larger than moduli measured by micropipette aspiration or other low strain rate techniques.

  11. Ultra-high performance size-exclusion chromatography in polar solvents.

    Science.gov (United States)

    Vancoillie, Gertjan; Vergaelen, Maarten; Hoogenboom, Richard

    2016-12-23

    Size-exclusion chromatography (SEC) is amongst the most widely used polymer characterization methods in both academic and industrial polymer research allowing the determination of molecular weight and distribution parameters, i.e. the dispersity (Ɖ), of unknown polymers. The many advantages, including accuracy, reproducibility and low sample consumption, have contributed to the worldwide success of this analytical technique. The current generation of SEC systems have a stationary phase mostly containing highly porous, styrene-divinylbenzene particles allowing for a size-based separation of various polymers in solution but limiting the flow rate and solvent compatibility. Recently, sub-2μm ethylene-bridged hybrid (BEH) packing materials have become available for SEC analysis. These packing materials can not only withstand much higher pressures up to 15000psi but also show high spatial stability towards different solvents. Combining these BEH columns with the ultra-high performance LC (UHPLC) technology opens up UHP-SEC analysis, showing strongly reduced runtimes and unprecedented solvent compatibility. In this work, this novel characterization technique was compared to conventional SEC using both highly viscous and highly polar solvents as eluent, namely N,N-dimethylacetamide (DMAc), N,N-dimethylformamide (DMF) and methanol, focusing on the suitability of the BEH-columns for analysis of highly functional polymers. The results show a high functional group compatibility comparable with conventional SEC with remarkably short runtimes and enhanced resolution in methanol. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Performance analysis

    International Nuclear Information System (INIS)

    2008-05-01

    This book introduces energy and resource technology development business with performance analysis, which has business division and definition, analysis of current situation of support, substance of basic plan of national energy, resource technique development, selection of analysis index, result of performance analysis by index, performance result of investigation, analysis and appraisal of energy and resource technology development business in 2007.

  13. High-dose-rate brachytherapy alone post-hysterectomy for endometrial cancer

    International Nuclear Information System (INIS)

    MacLeod, Craig; Fowler, Allan; Duval, Peter; D'Costa, Ieta; Dalrymple, Chris; Firth, Ian; Elliott, Peter; Atkinson, Ken; Carter, Jonathan

    1998-01-01

    Purpose: To evaluate the outcome of post-hysterectomy adjuvant vaginal high-dose-rate (HDR) brachytherapy. Methods and Materials: A retrospective analysis was performed on a series of 143 patients with endometrial cancer treated with HDR brachytherapy alone post-hysterectomy from 1985 to June 1993. Of these patients, 141 received 34 Gy in four fractions prescribed to the vaginal mucosa in a 2-week period. The median follow-up was 6.9 years. Patients were analyzed for treatment parameters, survival, local recurrence, distant relapse, and toxicity. Results: Five-year relapse free survival and overall survival was 100% and 88% for Stage 1A, 98% and 94% for Stage IB, 100% and 86% for Stage IC, and 92% and 92% for Stage IIA. The overall vaginal recurrence rate was 1.4%. The overall late-toxicity rate was low, and no RTOG grade 3, 4, or 5 complications were recorded. Conclusion: These results are similar to reported international series that have used either low-dose-rate or HDR brachytherapy. The biological effective dose was low for both acute and late responding tissues compared with some of the HDR brachytherapy series, and supports using this lower dose and possibly decreasing late side-effects with no apparent increased risk of vaginal recurrence

  14. Chemical fingerprint of Ganmaoling granule by double-wavelength ultra high performance liquid chromatography and ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Lou, Qiong; Ye, Xiaolan; Zhou, Yingyi; Li, Hua; Song, Fenyun

    2015-06-01

    A method incorporating double-wavelength ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry was developed for the investigation of the chemical fingerprint of Ganmaoling granule. The chromatographic separations were performed on an ACQUITY UPLC HSS C18 column (2.1 × 50 mm, 1.8 μm) at 30°C using gradient elution with water/formic acid (1%) and acetonitrile at a flow rate of 0.4 mL/min. A total of 11 chemical constituents of Ganmaoling granule were identified from their molecular weight, UV spectra, tandem mass spectrometry data, and retention behavior by comparing the results with those of the reference standards or literature. And 25 peaks were selected as the common peaks for fingerprint analysis to evaluate the similarities among 25 batches of Ganmaoling granule. The results of principal component analysis and orthogonal projection to latent structures discriminant analysis showed that the important chemical markers that could distinguish the different batches were revealed as 4,5-di-O-caffeoylquinic acid, 3,5-di-O-caffeoylquinic acid, and 4-O-caffeoylquinic acid. This is the first report of the ultra high performance liquid chromatography chemical fingerprint and component identification of Ganmaoling granule, which could lay a foundation for further studies of Ganmaoling granule. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Cost-Effectiveness Analysis in Practice: Interventions to Improve High School Completion

    Science.gov (United States)

    Hollands, Fiona; Bowden, A. Brooks; Belfield, Clive; Levin, Henry M.; Cheng, Henan; Shand, Robert; Pan, Yilin; Hanisch-Cerda, Barbara

    2014-01-01

    In this article, we perform cost-effectiveness analysis on interventions that improve the rate of high school completion. Using the What Works Clearinghouse to select effective interventions, we calculate cost-effectiveness ratios for five youth interventions. We document wide variation in cost-effectiveness ratios between programs and between…

  16. High-Bandwidth Tactical-Network Data Analysis in a High-Performance-Computing (HPC) Environment: Transport Protocol (Transmission Control Protocol/User Datagram Protocol [TCP/UDP]) Analysis

    Science.gov (United States)

    2015-09-01

    the network Mac8 Medium Access Control ( Mac ) (Ethernet) address observed as destination for outgoing packets subsessionid8 Zero-based index of...15. SUBJECT TERMS tactical networks, data reduction, high-performance computing, data analysis, big data 16. SECURITY CLASSIFICATION OF: 17...Integer index of row cts_deid Device (instrument) Identifier where observation took place cts_collpt Collection point or logical observation point on

  17. The Role of Performance Management in Creating and Maintaining a High-Performance Organization

    Directory of Open Access Journals (Sweden)

    André A. de Waal

    2015-04-01

    Full Text Available There is still a good deal of confusion in the literature about how the use of a performance management system affects overall organizational performance. Some researchers find that performance management enhances both the financial and non-financial results of an organization, while others do not find any positive effects or, at most, ambiguous effects. An important step toward getting more clarity in this relationship is to investigate the role performance management plays in creating and maintaining a high-performance organization (HPO. The purpose of this study is to integrate performance management analysis (PMA and high-performance organization (HPO. A questionnaire combining questions on PMA dimensions and HPO factors was administered to two European-based multinational firms. Based on 468 valid questionnaires, a correlation analysis was performed on the PMA dimensions and the HPO factors in order to test the impact of performance management on the factors of high organizational performance. The results show strong and significant correlations between all the PMA dimensions and all the HPO factors, indicating that a performance management system that fosters performance-driven behavior in the organization is of critical importance to strengthen overall financial and non-financial performance.

  18. Impression Management and Interview and Job Performance Ratings: A Meta-Analysis of Research Design with Tactics in Mind.

    Science.gov (United States)

    Peck, Jessica A; Levashina, Julia

    2017-01-01

    Impression management (IM) is pervasive in interview and job performance settings. We meta-analytically examine IM by self- and other-focused tactics to establish base rates of tactic usage, to understand the impact of tactics on interview and job performance ratings, and to examine the moderating effects of research design. Our results suggest IM is used more frequently in the interview rather than job performance settings. Self-focused tactics are more effective in the interview rather than in job performance settings, and other-focused tactics are more effective in job performance settings rather than in the interview. We explore several research design moderators including research fidelity, rater, and participants. IM has a somewhat stronger impact on interview ratings in lab settings than field settings. IM also has a stronger impact on interview ratings when the target of IM is also the rater of performance than when the rater of performance is an observer. Finally, labor market participants use IM more frequently and more effectively than students in interview settings. Our research has implications for understanding how different IM tactics function in interview and job performance settings and the effects of research design on IM frequency and impact.

  19. High-dose-rate brachytherapy in the treatment of uterine cervix cancer. Analysis of dose effectiveness and late complications

    International Nuclear Information System (INIS)

    Ferrigno, Robson; Novaes, Paulo Eduardo Ribeiro dos Santos; Pellizzon, Antonio Cassio Assis; Maia, Maria Aparecida Conte; Fogarolli, Ricardo Cesar; Gentil, Andre Cavalcanti; Salvajoli, Joao Victor

    2001-01-01

    Purpose: This retrospective analysis aims to report results of patients with cervix cancer treated by external beam radiotherapy (EBR) and high-dose-rate (HDR) brachytherapy. Methods and Materials: From September 1992 to December 1996, 138 patients with FIGO Stages II and III and mean age of 56 years were treated. Median EBR to the whole pelvis was 45 Gy in 25 fractions. Parametrial boost was performed in 93% of patients, with a median dose of 14.4 Gy. Brachytherapy with HDR was performed during EBR or following its completion with a dose of 24 Gy in four weekly fractions of 6 Gy to point A. Median overall treatment time was of 60 days. Patient age, tumor stage, and overall treatment time were variables analyzed for survival and local control. Cumulative biologic effective dose (BED) at rectal and bladder reference points were correlated with late complications in these organs and dose of EBR at parametrium was correlated with small bowel complications. Results: Median follow-up time was 38 months. Overall survival, disease-free survival, and local control at 5 years was 53.7%, 52.7%, and 62%, respectively. By multivariate and univariate analysis, overall treatment time up to 50 days was the only statistically significant adverse variable for overall survival (p=0.003) and actuarial local control (p=0.008). The 5-year actuarial incidence of rectal, bladder, and small bowel late complications was 16%, 11%, and 14%, respectively. Patients treated with cumulative BED at rectum points above 110 Gy 3 and at bladder point above 125 Gy 3 had a higher but not statistically significant 5-year actuarial rate of complications at these organs (18% vs. 12%, p=0.49 and 17% vs. 9%, p=0.20, respectively). Patients who received parametrial doses larger than 59 Gy had a higher 5-year actuarial rate of complications in the small bowel; however, this was not statistically significant (19% vs. 10%, p=0.260). Conclusion: This series suggests that 45 Gy to the whole pelvis combined with

  20. Solidification at the High and Low Rate Extreme

    Energy Technology Data Exchange (ETDEWEB)

    Meco, Halim [Iowa State Univ., Ames, IA (United States)

    2004-12-19

    The microstructures formed upon solidification are strongly influenced by the imposed growth rates on an alloy system. Depending on the characteristics of the solidification process, a wide range of growth rates is accessible. The prevailing solidification mechanisms, and thus the final microstructure of the alloy, are governed by these imposed growth rates. At the high rate extreme, for instance, one can have access to novel microstructures that are unattainable at low growth rates. While the low growth rates can be utilized for the study of the intrinsic growth behavior of a certain phase growing from the melt. Although the length scales associated with certain processes, such as capillarity, and the diffusion of heat and solute, are different at low and high rate extremes, the phenomena that govern the selection of a certain microstructural length scale or a growth mode are the same. Consequently, one can analyze the solidification phenomena at both high and low rates by using the same governing principles. In this study, we examined the microstructural control at both low and high extremes. For the high rate extreme, the formation of crystalline products and factors that control the microstructure during rapid solidification by free-jet melt spinning are examined in Fe-Si-B system. Particular attention was given to the behavior of the melt pool at different quench-wheel speeds. Since the solidification process takes place within the melt-pool that forms on the rotating quench-wheel, we examined the influence of melt-pool dynamics on nucleation and growth of crystalline solidification products and glass formation. High-speed imaging of the melt-pool, analysis of ribbon microstructure, and measurement of ribbon geometry and surface character all indicate upper and lower limits for melt-spinning rates for which nucleation can be avoided, and fully amorphous ribbons can be achieved. Comparison of the relevant time scales reveals that surface-controlled melt

  1. High performance thin layer chromatography fingerprint analysis of guava (Psidium guajava) leaves

    Science.gov (United States)

    Astuti, M.; Darusman, L. K.; Rafi, M.

    2017-05-01

    High-performance thin layer chromatography (HPTLC) fingerprint analysis is commonly used for quality control of medicinal plants in term of identification and authentication. In this study, we have been developed HPTLC fingerprint analysis for identification of guava (Psidium guajava) leaves raw material. A mixture of chloroform, acetone, and formic acid in the ratio 10:2:1 was used as the optimum mobile phase in HPTLC silica plate and with 13 bands were detected. As reference marker we chose gallic acid (Rf = 0.21) and catechin (Rf = 0.11). The two compound were detected as pale black bands at 366 nm after derivatization with sulfuric acid 10% v/v (in methanol) reagent. Validation of the method was met within validation criteria, so the developed method could be used for quality control of guava leaves.

  2. 5 CFR 9901.412 - Rating and rewarding performance.

    Science.gov (United States)

    2010-01-01

    ...'s performance with respect to his or her performance expectations, as amplified through work... rating of record. (f) A Pay Pool Panel will — (1) Review recommended ratings of record, share assignments... consistency across the pay pool; and (2) Afford the rating official the opportunity to provide further...

  3. Exploring Incomplete Rating Designs with Mokken Scale Analysis

    Science.gov (United States)

    Wind, Stefanie A.; Patil, Yogendra J.

    2018-01-01

    Recent research has explored the use of models adapted from Mokken scale analysis as a nonparametric approach to evaluating rating quality in educational performance assessments. A potential limiting factor to the widespread use of these techniques is the requirement for complete data, as practical constraints in operational assessment systems…

  4. A new high rate positron lifetime measurement system

    International Nuclear Information System (INIS)

    Bedwell, M.O.; Paulus, T.J.

    1979-01-01

    Positron lifetime measuring system, a technique to perform non-destructive studies on the internal structure of materials, has many components common to those used for nuclear time spectroscopy systems. In each case, a timing coincidence curve is measured for the energy range of interest, and this is accomplished in a typical timing coincidence system. The paper first describes the conventional timing coincidence system, then a new fast timing system is introduced. Comparing to the conventional fast/slow timing system, the fast timing technique offers reduced complexity, lower system cost, and improved high data rate capability. Experimental results show that the FWHM timing resolution ranges from 190 ps for a 1.1 : 1 dynamic range to 337 ps for a 100 : 1 dynamic range of signals with 60 Co. As for the timing resolution as a function of energy, the FWHM resolution for each channel ranges from 124 ps at 1 MeV to 400 ps at 100 keV. Since the excellent timing performance is maintained even at very high input rate, the experimenters can use much more active sources to increase the true coincidence rate and reduce data accumulation time. This method has the added advantage of minimizing long term drift effects since the experiments can be conducted in less time. (Wakatsuki, Y.)

  5. High-performance analysis of filtered semantic graphs

    OpenAIRE

    Buluç, A; Fox, A; Gilbert, JR; Kamil, S; Lugowski, A; Oliker, L; Williams, S

    2012-01-01

    High performance is a crucial consideration when executing a complex analytic query on a massive semantic graph. In a semantic graph, vertices and edges carry \\attributes" of various types. Analytic queries on semantic graphs typically depend on the values of these attributes; thus, the computation must either view the graph through a filter that passes only those individual vertices and edges of interest, or else must first materialize a subgraph or subgraphs consisting of only the vertices ...

  6. Persistent Ratee Contaminants in Performance Appraisal.

    Science.gov (United States)

    Van Fleet, David D.; Chamberlain, Howard

    The hypothesis that conventional approaches to evaluating contaminants in performance appraisal overlook important individual ratee effects was examined. A rating form was developed that consisted of the following dimensions and behaviors: warmth; guided discourse or indirect teaching methods; control of subject matter; enthusiasm and reinforcing;…

  7. Self-Informant Agreement in Well-Being Ratings: A Meta-Analysis

    Science.gov (United States)

    Schneider, Leann; Schimmack, Ulrich

    2009-01-01

    A meta-analysis of published studies that reported correlations between self-ratings and informant ratings of well-being (life-satisfaction, happiness, positive affect, negative affect) was performed. The average self-informant correlation based on 44 independent samples and 81 correlations for a total of 8,897 participants was r = 0.42 [99%…

  8. Automated high performance liquid chromatography and liquid scintillation counting determination of pesticide mixture octanol/water partition rates

    International Nuclear Information System (INIS)

    Moody, R.P.; Carroll, J.M.; Kresta, A.M.

    1987-01-01

    Two novel methods are reported for measuring octanol/water partition rates of pesticides. A liquid scintillation counting (LSC) method was developed for automated monitoring of 14 C-labeled pesticides partitioning in biphasic water/octanol cocktail systems with limited success. A high performance liquid chromatography (HPLC) method was developed for automated partition rate monitoring of several constituents in a pesticide mixture, simultaneously. The mean log Kow +/- SD determined from triplicate experimental runs were for: 2,4-D-DMA (2,4-dichlorophenoxyacetic acid dimethylamine), 0.65 +/- .17; Deet (N,N-diethyl-m-toluamide), 2.02 +/- .01; Guthion (O,O-dimethyl-S-(4-oxo-1,2,3-benzotriazin-3(4H)-ylmethyl) phosphorodithioate), 2.43 +/- .03; Methyl-Parathion (O,O-dimethyl-O-(p-nitrophenyl) phosphorothioate), 2.68 +/- .05; and Fenitrothion (O,O-dimethyl O-(4-nitro-m-tolyl) phosphorothioate), 3.16 +/- .03. A strong positive linear correlation (r = .9979) was obtained between log Kow and log k' (log Kow = 2.35 (log k') + 0.63). The advantages that this automated procedure has in comparison with the standard manual shake-flask procedure are discussed

  9. High-performance solid-state supercapacitors based on graphene-ZnO hybrid nanocomposites

    Science.gov (United States)

    Li, Zijiong; Zhou, Zhihua; Yun, Gaoqian; Shi, Kai; Lv, Xiaowei; Yang, Baocheng

    2013-11-01

    In this paper, we report a facile low-cost synthesis of the graphene-ZnO hybrid nanocomposites for solid-state supercapacitors. Structural analysis revealed a homogeneous distribution of ZnO nanorods that are inserted in graphene nanosheets, forming a sandwiched architecture. The material exhibited a high specific capacitance of 156 F g-1 at a scan rate of 5 mV.s-1. The fabricated solid-state supercapacitor device using these graphene-ZnO hybrid nanocomposites exhibits good supercapacitive performance and long-term cycle stability. The improved supercapacitance property of these materials could be ascribed to the increased conductivity of ZnO and better utilization of graphene. These results demonstrate the potential of the graphene-ZnO hybrid nanocomposites as an electrode in high-performance supercapacitors.

  10. Improving the performance of high-energy physics analysis through bitmap indices

    CERN Document Server

    Stockinger, K; Hoschek, W; Schikuta, E

    2000-01-01

    Bitmap indices are popular multi-dimensional data structures for accessing read-mostly data such as data warehouse (DW) applications, decision support systems (DSS) and online analytical processing (OLAP). One of their main strengths is that they provide good performance characteristics for complex adhoc queries and an efficient combination of multiple index dimensions in one query. Considerable research work has been done in the area of finite (and low) attribute cardinalities. However, additional complexity is imposed on the design of bitmap indices for high cardinality or even non-discrete attributes, where different optimisation techniques than the ones proposed so far have to be applied. We discuss the design and implementation of bitmap indices for high-energy physics (HEP) analysis, where the potential search space consists of hundreds of independent dimensions. A single HEP query typically covers 10 to 100 dimensions out of the whole search space. In this context we evaluated two different bitmap enco...

  11. High repetition rate intense ion beam source

    International Nuclear Information System (INIS)

    Hammer, D.A.; Glidden, S.C.; Noonan, B.

    1992-01-01

    This final report describes a ≤ 150kV, 40kA, 100ns high repetition rate pulsed power system and intense ion beam source which is now in operation at Cornell University. Operation of the Magnetically-controlled Anode Plasma (MAP) ion diode at > 100Hz (burst mode for up to 10 pulse bursts) provides an initial look at repetition rate limitations of both the ion diode and beam diagnostics. The pulsed power systems are capable of ≥ 1kHz operation (up to 10 pulse bursts), but ion diode operation was limited to ∼100Hz because of diagnostic limitations. By varying MAP diode operating parameters, ion beams can be extracted at a few 10s of keV or at up to 150keV, the corresponding accelerating gap impedance ranging from about 1Ω to about 10Ω. The ability to make hundreds of test pulses per day at an average repetition rate of about 2 pulses per minute permits statistical analysis of diode operation as a function of various parameters. Most diode components have now survived more than 10 4 pulses, and the design and construction of the various pulsed power components of the MAP diode which have enabled us to reach this point are discussed. A high speed data acquisition system and companion analysis software capable of acquiring pulse data at 1ms intervals (in bursts of up to 10 pulses) and processing it in ≤ min is described

  12. Generation of µW level plateau harmonics at high repetition rate.

    Science.gov (United States)

    Hädrich, S; Krebs, M; Rothhardt, J; Carstens, H; Demmler, S; Limpert, J; Tünnermann, A

    2011-09-26

    The process of high harmonic generation allows for coherent transfer of infrared laser light to the extreme ultraviolet spectral range opening a variety of applications. The low conversion efficiency of this process calls for optimization or higher repetition rate intense ultrashort pulse lasers. Here we present state-of-the-art fiber laser systems for the generation of high harmonics up to 1 MHz repetition rate. We perform measurements of the average power with a calibrated spectrometer and achieved µW harmonics between 45 nm and 61 nm (H23-H17) at a repetition rate of 50 kHz. Additionally, we show the potential for few-cycle pulses at high average power and repetition rate that may enable water-window harmonics at unprecedented repetition rate. © 2011 Optical Society of America

  13. Shutdown dose rate analysis with CAD geometry, Cartesian/tetrahedral mesh, and advanced variance reduction

    International Nuclear Information System (INIS)

    Biondo, Elliott D.; Davis, Andrew; Wilson, Paul P.H.

    2016-01-01

    Highlights: • A CAD-based shutdown dose rate analysis workflow has been implemented. • Cartesian and superimposed tetrahedral mesh are fully supported. • Biased and unbiased photon source sampling options are available. • Hybrid Monte Carlo/deterministic techniques accelerate photon transport. • The workflow has been validated with the FNG-ITER benchmark problem. - Abstract: In fusion energy systems (FES) high-energy neutrons born from burning plasma activate system components to form radionuclides. The biological dose rate that results from photons emitted by these radionuclides after shutdown—the shutdown dose rate (SDR)—must be quantified for maintenance planning. This can be done using the Rigorous Two-Step (R2S) method, which involves separate neutron and photon transport calculations, coupled by a nuclear inventory analysis code. The geometric complexity and highly attenuating configuration of FES motivates the use of CAD geometry and advanced variance reduction for this analysis. An R2S workflow has been created with the new capability of performing SDR analysis directly from CAD geometry with Cartesian or tetrahedral meshes and with biased photon source sampling, enabling the use of the Consistent Adjoint Driven Importance Sampling (CADIS) variance reduction technique. This workflow has been validated with the Frascati Neutron Generator (FNG)-ITER SDR benchmark using both Cartesian and tetrahedral meshes and both unbiased and biased photon source sampling. All results are within 20.4% of experimental values, which constitutes satisfactory agreement. Photon transport using CADIS is demonstrated to yield speedups as high as 8.5·10"5 for problems using the FNG geometry.

  14. Success rates of a skeletal anchorage system in orthodontics: A retrospective analysis.

    Science.gov (United States)

    Lam, Raymond; Goonewardene, Mithran S; Allan, Brent P; Sugawara, Junji

    2018-01-01

    To evaluate the premise that skeletal anchorage with SAS miniplates are highly successful and predictable for a range of complex orthodontic movements. This retrospective cross-sectional analysis consisted of 421 bone plates placed by one clinician in 163 patients (95 female, 68 male, mean age 29.4 years ± 12.02). Simple descriptive statistics were performed for a wide range of malocclusions and desired movements to obtain success, complication, and failure rates. The success rate of skeletal anchorage system miniplates was 98.6%, where approximately 40% of cases experienced mild complications. The most common complication was soft tissue inflammation, which was amenable to focused oral hygiene and antiseptic rinses. Infection occurred in approximately 15% of patients where there was a statistically significant correlation with poor oral hygiene. The most common movements were distalization and intrusion of teeth. More than a third of the cases involved complex movements in more than one plane of space. The success rate of skeletal anchorage system miniplates is high and predictable for a wide range of complex orthodontic movements.

  15. Comparison of the success rate between self-drilling and self-tapping miniscrews: a systematic review and meta-analysis.

    Science.gov (United States)

    Yi, Jianru; Ge, Mengke; Li, Meile; Li, Chunjie; Li, Yu; Li, Xiaobing; Zhao, Zhihe

    2017-06-01

    Both the self-drilling and self-tapping miniscrews have been commonly used as anchorage reinforcement devices in orthodontic treatment. The aim of this study was to compare the success rates of self-drilling and self-tapping miniscrews in orthodontic practice. Literature searches were performed by electronic search in database including PubMed, Embase, Cochrane Central Register of Controlled Trials, China National Knowledge Infrastructure and SIGLE, and manual search of relevant journals and reference lists of included studies. Randomized controlled trials, clinical controlled trials and cohort studies comparing the success rates of self-drilling and self-tapping miniscrews as orthodontic anchorage. The data of success rates and root contact rates were extracted by two investigators independently. After evaluating the risk of bias, the odds ratios (ORs) and 95% confidence intervals (CIs) were calculated. Subgroup analysis was performed on the basis of study design, follow-ups, participant ages and immediate/delayed loading. Sensitivity analysis was performed to test the stability of the results in meta-analysis. Six studies assessed as high quality were included in the meta-analysis. The meta-analysis results showed no difference between the two types of screws in the success rates. The root contact rates of the two screws were similar, while self-drilling miniscrews displayed higher risk of failure when contacting with a tooth root. Currently available clinical evidence suggests that the success rates of self-tapping and self-drilling miniscrews are similar. Determination of the position and direction of placement should be more precise when self-drilling miniscrews are used in sites with narrow root proximity. None. None. © The Author 2016. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

  16. The Relationship of Practice Exposure and Injury Rate on Game Performance and Season Success in Professional Male Basketball

    Directory of Open Access Journals (Sweden)

    Toni Caparrós, Eduard Alentorn-Geli, Gregory D. Myer, Lluís Capdevila, Kristian Samuelsson, Bruce Hamilton, Gil Rodas

    2016-09-01

    Full Text Available The objectives of this study were to determine the relationship among game performance, injury rate, and practice exposure in a professional male basketball team. A retroospective analysis of prospective collected data was conducted over seven consecutive seasons (2007/2008 to 2013/2014. Data collection included sports performance during competition (statistical evaluation, injury rate, and total exposure (games and practices. Over the surveillance period, 162 injuries (91 practice; 71 matches occurred over 32,668 hours of exposure (556 games and 2005 practices. There was a strong positive correlation between: 1 exposure (total number of practices and hours of exposure and the total number of injuries (r = 0.77; p = 0.04; 2 exposure (total hours of exposure and total hours of practice exposure and performance (total team ranking (r = 0.77 and p = 0.04, and r = 0.8 and p = 0.03, respectively; and 3 total number of injuries and performance (total team ranking (r = 0.84; p = 0.02. While increasing practice and competition time is related to greater team performance, it also increases the number of injuries. However, higher injury rates were not associated with worse overall team performance. Efforts to reduce high-risk activity during practice, optimally replaced with injury prevention training, might help to reduce injury risk.

  17. Adaptive rate selection scheme for video transmission to resolve IEEE 802.11 performance anomaly

    Science.gov (United States)

    Tang, Guijin; Zhu, Xiuchang

    2011-10-01

    Multi-rate transmission may lead to performance anomaly in an IEEE 802.11 network. It will decrease the throughputs of all the higher rate stations. This paper proposes an adaptive rate selection scheme for video service when performance anomaly occurs. Considering that video has the characteristic of tolerance to packet loss, we actively drop several packets so as to select the rates as high as possible for transmitting packets. Experiment shows our algorithm can decrease the delay and jitter of video, and improve the system throughput as well.

  18. Obstetrician perceptions of the causes of high cesarean delivery rates in Turkey.

    Science.gov (United States)

    Küçük, Mert

    2017-07-01

    To assess obstetricians' perceptions surrounding cesarean delivery rates in Turkey. The present cross-sectional descriptive study was performed between May 1 and June 30, 2016. Practicing obstetricians with contact details known by the researchers and those attending a conference in Turkey were asked to complete a self-administered questionnaire that collected demographic data and information on participants' opinions, beliefs, knowledge, attitudes, and practices related to cesarean delivery. There were 100 obstetricians who responded to the survey. Awareness of high cesarean delivery rates was reported by 96 (96%) participants and 95 (95%) respondents said they were supportive of efforts to reduce it. There were 60 (60%), 83 (83%), and 100 (100%) participants aware of associations between high cesarean delivery rates and increased maternal and infant mortality; increased risk of uterine rupture; and increased risk of placenta previa, placenta accreta, and emergency cesarean hysterectomy, respectively. The most commonly reported reason for high cesarean delivery rates was high compensation costs during medical litigation legal proceedings, reported by all 100 (100%) participants. Participants were generally aware of the risks associated with high cesarean delivery rates. The results suggest that the greatest concern among obstetricians who perform cesarean deliveries was malpractice litigation. © 2017 International Federation of Gynecology and Obstetrics.

  19. The Effect of Exposure to High Noise Levels on the Performance and Rate of Error in Manual Activities.

    Science.gov (United States)

    Khajenasiri, Farahnaz; Zamanian, Alireza; Zamanian, Zahra

    2016-03-01

    Sound is among the significant environmental factors for people's health, and it has an important role in both physical and psychological injuries, and it also affects individuals' performance and productivity. The aim of this study was to determine the effect of exposure to high noise levels on the performance and rate of error in manual activities. This was an interventional study conducted on 50 students at Shiraz University of Medical Sciences (25 males and 25 females) in which each person was considered as its own control to assess the effect of noise on her or his performance at the sound levels of 70, 90, and 110 dB by using two factors of physical features and the creation of different conditions of sound source as well as applying the Two-Arm coordination Test. The data were analyzed using SPSS version 16. Repeated measurements were used to compare the length of performance as well as the errors measured in the test. Based on the results, we found a direct and significant association between the levels of sound and the length of performance. Moreover, the participant's performance was significantly different for different sound levels (at 110 dB as opposed to 70 and 90 dB, p < 0.05 and p < 0.001, respectively). This study found that a sound level of 110 dB had an important effect on the individuals' performances, i.e., the performances were decreased.

  20. Quantitative analysis of benzodiazepines in vitreous humor by high-performance liquid chromatography

    Science.gov (United States)

    Bazmi, Elham; Behnoush, Behnam; Akhgari, Maryam; Bahmanabadi, Leila

    2016-01-01

    Objective: Benzodiazepines are frequently screened drugs in emergency toxicology, drugs of abuse testing, and in forensic cases. As the variations of benzodiazepines concentrations in biological samples during bleeding, postmortem changes, and redistribution could be biasing forensic medicine examinations, hence selecting a suitable sample and a validated accurate method is essential for the quantitative analysis of these main drug categories. The aim of this study was to develop a valid method for the determination of four benzodiazepines (flurazepam, lorazepam, alprazolam, and diazepam) in vitreous humor using liquid–liquid extraction and high-performance liquid chromatography. Methods: Sample preparation was carried out using liquid–liquid extraction with n-hexane: ethyl acetate and subsequent detection by high-performance liquid chromatography method coupled to diode array detector. This method was applied to quantify benzodiazepines in 21 authentic vitreous humor samples. Linear curve for each drug was obtained within the range of 30–3000 ng/mL with coefficient of correlation higher than 0.99. Results: The limit of detection and quantitation were 30 and 100 ng/mL respectively for four drugs. The method showed an appropriate intra- and inter-day precision (coefficient of variation forensic toxicology laboratory. PMID:27635251

  1. Energy performance ratings and house prices in Wales: An empirical study

    International Nuclear Information System (INIS)

    Fuerst, Franz; McAllister, Pat; Nanda, Anupam; Wyatt, Pete

    2016-01-01

    This paper investigates the effect of Energy Performance Certificate (EPC) ratings on residential prices in Wales. Drawing on a sample of approximately 192,000 transactions, the capitalisation of energy efficiency ratings into house prices is investigated using two approaches. The first adopts a cross-sectional framework to investigate the effect of EPC rating on price. The second approach applies a repeat-sales methodology to investigate the impact of EPC rating on house price appreciation. Statistically significant positive price premiums are estimated for dwellings in EPC bands A/B (12.8%) and C (3.5%) compared to houses in band D. For dwellings in band E (−3.6%) and F (−6.5%) there are statistically significant discounts. Such effects may not be the result of energy performance alone. In addition to energy cost differences, the price effect may be due to additional benefits of energy efficient features. An analysis of the private rental segment reveals that, in contrast to the general market, low-EPC rated dwellings were not traded at a significant discount. This suggests different implicit prices of potential energy savings for landlords and owner-occupiers.

  2. Effect of 2 soccer matches in a week on physical performance and injury rate.

    Science.gov (United States)

    Dupont, Gregory; Nedelec, Mathieu; McCall, Alan; McCormack, Derek; Berthoin, Serge; Wisløff, Ulrik

    2010-09-01

    Recovery duration may be too short during the congested fixtures of professional soccer players with regard to maintaining physical performance and a low injury rate. To analyze the effects of 2 matches per week on physical performance and injury rate in male elite soccer players. Cohort study; Level of evidence, 3. Match results, match-related physical performance, and injuries were monitored during 2 seasons (2007-2008 and 2008-2009) for 32 professional soccer players in a top-level team participating in the UEFA (Union of European Football Associations) Champions League. Total distance, high-intensity distance, sprint distance, and number of sprints were collected for 52 home matches. Injuries and player participation in matches and training were recorded throughout the full season. Physical performance, as characterized by total distance covered, high-intensity distance, sprint distance, and number of sprints, was not significantly affected by the number of matches per week (1 versus 2), whereas the injury rate was significantly higher when players played 2 matches per week versus 1 match per week (25.6 versus 4.1 injuries per 1000 hours of exposure; P physical performance tested but is not long enough to maintain a low injury rate. The present data highlight the need for player rotation and for improved recovery strategies to maintain a low injury rate among athletes during periods with congested match fixtures.

  3. High performance multi-channel high-speed I/O circuits

    CERN Document Server

    Oh, Taehyoun

    2013-01-01

    This book describes design techniques that can be used to mitigate crosstalk in high-speed I/O circuits. The focus of the book is in developing compact and low power integrated circuits for crosstalk cancellation, inter-symbol interference (ISI) mitigation and improved bit error rates (BER) at higher speeds. This book is one of the first to discuss in detail the problem of crosstalk and ISI mitigation encountered as data rates have continued beyond 10Gb/s. Readers will learn to avoid the data performance cliff, with circuits and design techniques described for novel, low power crosstalk cancel

  4. Notes on human performance analysis

    International Nuclear Information System (INIS)

    Hollnagel, E.; Pedersen, O.M.; Rasmussen, J.

    1981-06-01

    This paper contains a framework for the integration of observation and analysis of human performance in nuclear environments - real or simulated. It identifies four main sources of data, and describes the characteristic data types and methods of analysis for each source in relation to a common conceptual background. The general conclusion is that it is highly useful to combine the knowledge and experience from different contexts into coherent picture of how nuclear operators perform under varying circumstances. (author)

  5. Mechanical characterization of alloys in extreme conditions of high strain rates and high temperature

    Science.gov (United States)

    Cadoni, Ezio

    2018-03-01

    The aim of this paper is the description of the mechanical characterization of alloys under extreme conditions of temperature and loading. In fact, in the frame of the Cost Action CA15102 “Solutions for Critical Raw Materials Under Extreme Conditions (CRM-EXTREME)” this aspect is crucial and many industrial applications have to consider the dynamic response of materials. Indeed, for a reduction and substitution of CRMs in alloys is necessary to design the materials and understand if the new materials behave better or if the substitution or reduction badly affect their performance. For this reason, a deep knowledge of the mechanical behaviour at high strain-rates of considered materials is required. In general, machinery manufacturing industry or transport industry as well as energy industry have important dynamic phenomena that are simultaneously affected by extended strain, high strain-rate, damage and pressure, as well as conspicuous temperature gradients. The experimental results in extreme conditions of high strain rate and high temperature of an austenitic stainless steel as well as a high-chromium tempered martensitic reduced activation steel Eurofer97 are presented.

  6. Analysis of 10 metabolites of polymethoxyflavones with high sensitivity by electrochemical detection in high-performance liquid chromatography.

    Science.gov (United States)

    Zheng, Jinkai; Bi, Jinfeng; Johnson, David; Sun, Yue; Song, Mingyue; Qiu, Peiju; Dong, Ping; Decker, Eric; Xiao, Hang

    2015-01-21

    Polymethoxyflavones (PMFs) have been known as a type of bioactive flavones that possess various beneficial biological functions. Accumulating evidence demonstrated that the metabolites of PMFs, that is, hydroxyl PMFs (OH-PMFs), had more potent beneficial biological effects than their corresponding parent PMFs. To facilitate the further identification and quantification of OH-PMFs in biological samples, the aim of this study was to develop a methodology for the simultaneous determination of 10 OH-PMFs using high-performance liquid chromatography (HPLC) coupled with electrochemistry detection. The HPLC profiles of these 10 OH-PMFs affected by different chromatographic parameters (different organic composition in mobile phases, the concentration of trifluoroacetic acid, and the concentration of ammonium acetate) are fully discussed in this study. The optimal condition was selected for the following validation studies. The linearity of calibration curves, accuracy, and precision (intra- and interday) at three concentration levels (low, middle, and high concentration range) were verified. The regression equations were linear (r > 0.9992) over the range of 0.005-10 μM. The limit of detection for 10 OH-PMFs was in the range of 0.8-3.7 ng/mL (S/N = 3, 10 μL injection). The recovery rates ranged from 86.6 to 108.7%. The precisions of intraday and interday analyses were less than 7.37 and 8.63% for relative standard deviation, respectively. This validated method was applied for the analysis of a variety of samples containing OH-PMFs. This paper also gives an example of analyzing the metabolites of nobiletin in mouse urine using the developed method. The transformation from nobiletin to traces of 5-hydroxyl metabolites has been discovered by this effective method, and this is the first paper to report such an association.

  7. Can a single pain rating replace a multiple pain rating in third molar surgery studies? Analysis of 220 patients

    NARCIS (Netherlands)

    Martin, W.J.J.M.; Heymans, M.W.; Skorpil, N.E.; Forouzanfar, T.

    2012-01-01

    This study describes the comparison of multiple and single pain ratings in patients after surgical removal of the third molar. Correlation and agreement analysis were performed between the average pain intensity measured three times a day over a period of 7 days and one single pain rating

  8. Longitudinal analysis of high-technology medical services and hospital financial performance.

    Science.gov (United States)

    Zengul, Ferhat D; Weech-Maldonado, Robert; Ozaydin, Bunyamin; Patrician, Patricia A; OʼConnor, Stephen J

    U.S. hospitals have been investing in high-technology medical services as a strategy to improve financial performance. Despite the interest in high-tech medical services, there is not much information available about the impact of high-tech services on financial performance. The aim of this study was to examine the impact of high-tech medical services on financial performance of U.S. hospitals by using the resource-based view of the firm as a conceptual framework. Fixed-effects regressions with 2 years lagged independent variables using a longitudinal panel sample of 3,268 hospitals (2005-2010). It was hypothesized that hospitals with rare or large numbers (breadth) of high-tech medical services will experience better financial performance. Fixed effects regression results supported the link between a larger breadth of high-tech services and total margin, but only among not-for-profit hospitals. Both breadth and rareness of high-tech services were associated with high total margin among not-for-profit hospitals. Neither breadth nor rareness of high-tech services was associated with operating margin. Although breadth and rareness of high-tech services resulted in lower expenses per inpatient day among not-for-profit hospitals, these lower costs were offset by lower revenues per inpatient day. Enhancing the breadth of high-tech services may be a legitimate organizational strategy to improve financial performance, especially among not-for-profit hospitals. Hospitals may experience increased productivity and efficiency, and therefore lower inpatient operating costs, as a result of newer technologies. However, the negative impact on operating revenue should caution hospital administrators about revenue reducing features of these technologies, which may be related to the payer mix that these technologies may attract. Therefore, managers should consider both the cost and revenue implications of these technologies.

  9. Demo : an embedded vision system for high frame rate visual servoing

    NARCIS (Netherlands)

    Ye, Z.; He, Y.; Pieters, R.S.; Mesman, B.; Corporaal, H.; Jonker, P.P.

    2011-01-01

    The frame rate of commercial off-the-shelf industrial cameras is breaking the threshold of 1000 frames-per-second, the sample rate required in high performance motion control systems. On the one hand, it enables computer vision as a cost-effective feedback source; On the other hand, it imposes

  10. Effect-directed analysis via hyphenated high-performance thin-layer chromatography for bioanalytical profiling of sunflower leaves.

    Science.gov (United States)

    Móricz, Ágnes M; Ott, Péter G; Yüce, Imanuel; Darcsi, András; Béni, Szabolcs; Morlock, Gertrud E

    2018-01-19

    High-performance thin-layer chromatography (HPTLC) coupled with effect-directed analysis was used for non-targeted screening of sunflower leaf extract for components exhibiting antioxidant, antibacterial and/or cholinesterase enzyme inhibitory effects. The active compounds were characterized by HPTLC-electrospray ionization-high resolution mass spectrometry (ESI-HRMS) and HPTLC-Direct Analysis in Real Time (DART)-MS/MS. The latter ambient ionization technique (less soft than ESI) resulted in oxidation and fragmentation products and characteristic fragment ions. NMR spectroscopy after targeted isolation via preparative normal phase flash chromatography and semi-preparative reversed phase high-performance liquid chromatography supported the identification of two diterpenes to be (-)-kaur-16-en-19-oic acid and 15-α-angeloyloxy-ent-kaur-16-en-19-oic acid. Both compounds found to be multi-potent as they inhibited acetylcholinesterase and butyrylcholinesterase and showed antibacterial effects against Gram-positive Bacillus subtilis and Gram-negative Aliivibrio fischeri bacteria. Kaurenoic acid was also active against the Gram-negative pepper pathogenic Xanthomonas euvesicatoria bacteria. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Acidulants for japanese quails housed at high stocking rates at finishing phase

    Directory of Open Access Journals (Sweden)

    Ana Paula de Oliveira Saccomani

    2013-12-01

    Full Text Available The quail for being an alternative species will be able to supply a new market niche due to its fast growth, high laying rate, low feed intake, in addition to the increase of the acceptance of its products by the consumer. A growing interest in raising the stocking rates in the cages as an alternative to increase the performance of the stock is noticed; although studies demonstrate that high densities can result into unfavorable environment to the birds’ welfare with alterations in the performance of the flocks and as a stressing factor being able to alter the production and profitability of the flock. At high stocking rates, the birds become predisposed to aggressiveness reactions, presenting cannibalism behavior, besides the combination of factors such as pH, temperature, ventilation and humidity deficiency which create environmental conditions favorable for certain benign bacteria which utilize uric acid of the manure through their enzymatic complexes and produce ammonia, causing stress to birds and which can cause damages to performance with significant economic losses to the producer.  The experiment with 112-day duration was conducted with the objective of evaluating the inclusion of acidulants in the Japanese quails’ drinking water and verifying the effect on the stocking rate in cages. A completely randomized design with four treatments (2 stocking rates of quails x 2 additions of and 5 replications of 24 and 36 birds per cage, corresponding to the stocking rates of 141.67 and 94.44 cm2/bird, respectively, receiving or not acidulant in the water (acetic, lactic and phosphoric acid was utilized. Performance was evaluated through egg weight (EWg, egg yield (%Laying., egg mass (EMg/bird/day, feed intake (FIg/bird/day, feed conversion (FCkg/dz and FCkg/kg and mortality (%Mort. No significant statistical differences about the performance (P>0.05 were found. There was a significant effect (P<0.05 of the density for daily feed intake with

  12. Analysis of Outcomes for High Tibial Osteotomies Performed With Cartilage Restoration Techniques.

    Science.gov (United States)

    Kahlenberg, Cynthia A; Nwachukwu, Benedict U; Hamid, Kamran S; Steinhaus, Michael E; Williams, Riley J

    2017-02-01

    To evaluate reported medium- to long-term outcomes after high tibial osteotomy (HTO) with associated cartilage restoration procedures. A review of the MEDLINE database was performed. The inclusion criteria were English language, clinical outcome study with HTO as the primary procedure, use of a form of cartilage repair included, and the mean follow-up period of at least 2 years. Each identified study was reviewed for study design, patient demographics, type of procedures performed, clinical outcomes, progression to total knee arthroplasty, and complications. Eight hundred and twenty-seven patients (839 knees) were included. The most common cartilage preservation technique used in conjunction with HTO was microfracture (4 studies; 22.2%). The mean Lyscholm scores, reported in 50% of the studies, ranged from 40 to 65.7 preoperatively and improved to a range of 67 to 94.6 postoperatively. Four studies (22.2%) used a visual analog scale for evaluation of pain and all had a mean visual analog scale of less than 3 postoperatively. Among studies evaluating conversion to arthroplasty, the rate of conversion was 6.8% and the range of mean number of years from HTO to conversion was 4.9 to 13.0. The overall reported complication rate was 10.3%. HTO with cartilage restoration procedures provides reliable improvement in functional status in the medium- to long-term period after surgery and has potential to delay or avoid the need for knee arthroplasty surgery. Level IV, systematic review of Level I to IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  13. Transport analysis of high radiation and high density plasmas in the ASDEX Upgrade tokamak

    Directory of Open Access Journals (Sweden)

    Casali L.

    2014-01-01

    Full Text Available Future fusion reactors, foreseen in the “European road map” such as DEMO, will operate under more demanding conditions compared to present devices. They will require high divertor and core radiation by impurity seeding to reduce heat loads on divertor target plates. In addition, DEMO will have to work at high core densities to reach adequate fusion performance. The performance of fusion reactors depends on three essential parameters: temperature, density and energy confinement time. The latter characterizes the loss rate due to both radiation and transport processes. The DEMO foreseen scenarios described above were not investigated so far, but are now addressed at the ASDEX Upgrade tokamak. In this work we present the transport analysis of such scenarios. Plasma with high radiation by impurity seeding: transport analysis taking into account the radiation distribution shows no change in transport during impurity seeding. The observed confinement improvement is an effect of higher pedestal temperatures which extend to the core via stiffness. A non coronal radiation model was developed and compared to the bolometric measurements in order to provide a reliable radiation profile for transport calculations. High density plasmas with pellets: the analysis of kinetic profiles reveals a transient phase at the start of the pellet fuelling due to a slower density build up compared to the temperature decrease. The low particle diffusion can explain the confinement behaviour.

  14. High-performance nanostructured supercapacitors on a sponge

    KAUST Repository

    Chen, Wei

    2011-12-14

    A simple and scalable method has been developed to fabricate nanostructured MnO 2-carbon nanotube (CNT)-sponge hybrid electrodes. A novel supercapacitor, henceforth referred to as "sponge supercapacitor", has been fabricated using these hybrid electrodes with remarkable performance. A specific capacitance of 1230 F/g (based on the mass of MnO 2) can be reached. Capacitors based on CNT-sponge substrates (without MnO 2) can be operated even under a high scan rate of 200 V/s, and they exhibit outstanding cycle performance with only 2% degradation after 100000 cycles under a scan rate of 10 V/s. The MnO 2-CNT-sponge supercapacitors show only 4% of degradation after 10000 cycles at a charge-discharge specific current of 5 A/g. The specific power and energy of the MnO 2-CNT-sponge supercapacitors are high with values of 63 kW/kg and 31 Wh/kg, respectively. The attractive performances exhibited by these sponge supercapacitors make them potentially promising candidates for future energy storage systems. © 2011 American Chemical Society.

  15. Desensitization Using Bortezomib and High-dose Immunoglobulin Increases Rate of Deceased Donor Kidney Transplantation.

    Science.gov (United States)

    Jeong, Jong Cheol; Jambaldorj, Enkthuya; Kwon, Hyuk Yong; Kim, Myung-Gyu; Im, Hye Jin; Jeon, Hee Jung; In, Ji Won; Han, Miyeun; Koo, Tai Yeon; Chung, Junho; Song, Eun Young; Ahn, Curie; Yang, Jaeseok

    2016-02-01

    Combination therapy of intravenous immunoglobulin (IVIG) and rituximab showed a good transplant rate in highly sensitized wait-listed patients for deceased donor kidney transplantation (DDKT), but carried the risk of antibody-mediated rejection. The authors investigated the impact of a new combination therapy of bortezomib, IVIG, and rituximab on transplantation rate.This study was a prospective, open-labeled clinical trial. The desensitization regimen consisted of 2 doses of IVIG (2  g/kg), a single dose of rituximab (375  mg/m), and 4 doses of bortezomib (1.3  mg/m). The transplant rate was analyzed. Anti-Human leukocyte antigen (HLA) DRB antibodies were determined by a Luminex solid-phase bead assay at baseline and after 2, 3, and 6 months in the desensitized patients.There were 19 highly sensitized patients who received desensitization and 17 patients in the control group. Baseline values of class I and II panel reactive antibody (%, peak mean fluorescence intensity) were 83  ±  16.0 (14952  ±  5820) and 63  ±  36.0 (10321  ±  7421), respectively. Deceased donor kidney transplantation was successfully performed in 8 patients (42.1%) in the desensitization group versus 4 (23.5%) in the control group. Multivariate time-varying covariate Cox regression analysis showed that desensitization increased the probability of DDKT (hazard ratio, 46.895; 95% confidence interval, 3.468-634.132; P = 0.004). Desensitization decreased mean fluorescence intensity values of class I panel reactive antibody by 15.5% (20.8%) at 2 months. In addition, a liberal mismatch strategy in post hoc analysis increased the benefit of desensitization in donor-specific antibody reduction. Desensitization was well tolerated, and acute rejection occurred only in the control group.In conclusion, a desensitization protocol using bortezomib, high-dose IVIG, and rituximab increased the DDKT rate in highly sensitized, wait-listed patients.

  16. Flow and failure of an aluminium alloy from low to high temperature and strain rate

    Science.gov (United States)

    Sancho, Rafael; Cendón, David; Gálvez, Francisco

    2015-09-01

    The mechanical behaviour of an aluminium alloy is presented in this paper. The study has been carried out to analyse the flow and failure of the aluminium alloy 7075-T73. An experimental study has been planned performing tests of un-notched and notched tensile specimens at low strain rates using a servo-hydraulic machine. High strain rate tests have been carried out using the same geometry in a Hopkinson Split Tensile Bar. The dynamic experiments at low temperature were performed using a cryogenic chamber, and the high temperature ones with a furnace, both incorporated to the Hopkinson bar. Testing temperatures ranged from - 50 ∘C to 100 ∘C and the strain rates from 10-4 s-1 to 600 s-1. The material behaviour was modelled using the Modified Johnson-Cook model and simulated using LS-DYNA. The results show that the Voce type of strain hardening is the most accurate for this material, while the traditional Johnson-Cook is not enough accurate to reproduce the necking of un-notched specimens. The failure criterion was obtained by means of the numerical simulations using the analysis of the stress triaxiality versus the strain to failure. The diameters at the failure time were measured using the images taken with an image camera, and the strain to failure was computed for un-notched and notched specimens. The numerical simulations show that the analysis of the evolution of the stress triaxiality is crucial to achieve accurate results. A material model using the Modified Johnson-Cook for flow and failure is proposed.

  17. High-performance computing in accelerating structure design and analysis

    International Nuclear Information System (INIS)

    Li Zenghai; Folwell, Nathan; Ge Lixin; Guetz, Adam; Ivanov, Valentin; Kowalski, Marc; Lee, Lie-Quan; Ng, Cho-Kuen; Schussman, Greg; Stingelin, Lukas; Uplenchwar, Ravindra; Wolf, Michael; Xiao, Liling; Ko, Kwok

    2006-01-01

    Future high-energy accelerators such as the Next Linear Collider (NLC) will accelerate multi-bunch beams of high current and low emittance to obtain high luminosity, which put stringent requirements on the accelerating structures for efficiency and beam stability. While numerical modeling has been quite standard in accelerator R and D, designing the NLC accelerating structure required a new simulation capability because of the geometric complexity and level of accuracy involved. Under the US DOE Advanced Computing initiatives (first the Grand Challenge and now SciDAC), SLAC has developed a suite of electromagnetic codes based on unstructured grids and utilizing high-performance computing to provide an advanced tool for modeling structures at accuracies and scales previously not possible. This paper will discuss the code development and computational science research (e.g. domain decomposition, scalable eigensolvers, adaptive mesh refinement) that have enabled the large-scale simulations needed for meeting the computational challenges posed by the NLC as well as projects such as the PEP-II and RIA. Numerical results will be presented to show how high-performance computing has made a qualitative improvement in accelerator structure modeling for these accelerators, either at the component level (single cell optimization), or on the scale of an entire structure (beam heating and long-range wakefields)

  18. High-voltage power supply of ND6 portable dose rate meter

    International Nuclear Information System (INIS)

    Wang Shaling

    2001-01-01

    Portable dose rate meter needs to be equipped with a set of high-voltage power supply which is supplied by batteries and has characteristic of high quality, low energy expense and small size. The author introduces application conditions and performance guide line

  19. High Performance Parallel Multigrid Algorithms for Unstructured Grids

    Science.gov (United States)

    Frederickson, Paul O.

    1996-01-01

    We describe a high performance parallel multigrid algorithm for a rather general class of unstructured grid problems in two and three dimensions. The algorithm PUMG, for parallel unstructured multigrid, is related in structure to the parallel multigrid algorithm PSMG introduced by McBryan and Frederickson, for they both obtain a higher convergence rate through the use of multiple coarse grids. Another reason for the high convergence rate of PUMG is its smoother, an approximate inverse developed by Baumgardner and Frederickson.

  20. High-performance solid-state supercapacitors based on graphene-ZnO hybrid nanocomposites

    Science.gov (United States)

    2013-01-01

    In this paper, we report a facile low-cost synthesis of the graphene-ZnO hybrid nanocomposites for solid-state supercapacitors. Structural analysis revealed a homogeneous distribution of ZnO nanorods that are inserted in graphene nanosheets, forming a sandwiched architecture. The material exhibited a high specific capacitance of 156 F g−1 at a scan rate of 5 mV.s−1. The fabricated solid-state supercapacitor device using these graphene-ZnO hybrid nanocomposites exhibits good supercapacitive performance and long-term cycle stability. The improved supercapacitance property of these materials could be ascribed to the increased conductivity of ZnO and better utilization of graphene. These results demonstrate the potential of the graphene-ZnO hybrid nanocomposites as an electrode in high-performance supercapacitors. PMID:24215772

  1. Radionuclide release rates from spent fuel for performance assessment modeling

    International Nuclear Information System (INIS)

    Curtis, D.B.

    1994-01-01

    In a scenario of aqueous transport from a high-level radioactive waste repository, the concentration of radionuclides in water in contact with the waste constitutes the source term for transport models, and as such represents a fundamental component of all performance assessment models. Many laboratory experiments have been done to characterize release rates and understand processes influencing radionuclide release rates from irradiated nuclear fuel. Natural analogues of these waste forms have been studied to obtain information regarding the long-term stability of potential waste forms in complex natural systems. This information from diverse sources must be brought together to develop and defend methods used to define source terms for performance assessment models. In this manuscript examples of measures of radionuclide release rates from spent nuclear fuel or analogues of nuclear fuel are presented. Each example represents a very different approach to obtaining a numerical measure and each has its limitations. There is no way to obtain an unambiguous measure of this or any parameter used in performance assessment codes for evaluating the effects of processes operative over many millennia. The examples are intended to suggest by example that in the absence of the ability to evaluate accuracy and precision, consistency of a broadly based set of data can be used as circumstantial evidence to defend the choice of parameters used in performance assessments

  2. Research on mechanical and sensoric set-up for high strain rate testing of high performance fibers

    Science.gov (United States)

    Unger, R.; Schegner, P.; Nocke, A.; Cherif, C.

    2017-10-01

    Within this research project, the tensile behavior of high performance fibers, such as carbon fibers, is investigated under high velocity loads. This contribution (paper) focuses on the clamp set-up of two testing machines. Based on a kinematic model, weight optimized clamps are designed and evaluated. By analyzing the complex dynamic behavior of conventional high velocity testing machines, it has been shown that the impact typically exhibits an elastic characteristic. This leads to barely predictable breaking speeds and will not work at higher speeds when acceleration force exceeds material specifications. Therefore, a plastic impact behavior has to be achieved, even at lower testing speeds. This type of impact behavior at lower speeds can be realized by means of some minor test set-up adaptions.

  3. Performance Analysis of Multi Stage Safety Injection Tank

    International Nuclear Information System (INIS)

    Shin, Soo Jai; Kim, Young In; Bae, Youngmin; Kang, Han-Ok; Kim, Keung Koo

    2015-01-01

    In general the integral reactor has such characteristics, the integral reactor requires a high flow rate of coolant safety injection at the initial stage of the accident in which the core level is relatively fast decreased, A medium flow rate of coolant safety injection at the early and middle stages of the accident in which the coolant discharge flow rate is relatively large due to a high internal pressure of the reactor vessel, and a low flow rate of coolant safety injection is required at the middle and late stages of the accident in which the coolant discharge flow rate is greatly reduced due to a decreased pressure of the reactor vessel. It is noted that a high flow rate of the integral reactor is quite smaller compared to a flow rate required in the commercial loop type reactor. However, a nitrogen pressurized safety injection tank has been typically designed to quickly inject a high flow rate of coolant when the internal pressure of the reactor vessel is rapidly decreased, and a core makeup tank has been designed to safely inject at a single mode flow rate due to a gravitational head of water subsequent to making a pressure balance between the reactor vessel and core makeup tank. As a result, in order to compensate such a disadvantage, various type systems are used in a complicated manner in a reactor according to the required characteristic of safety injection during an accident. In the present study, we have investigated numerically the performance of the multi stage safety injection tank. A parameter study has performed to understand the characteristics of the multi stage safety injection tank. The performance of the multi stage safety injection tank has been investigated numerically. When an accident occurs, the coolant in the multi stage safety injection tank is injected into a reactor vessel by a gravitational head of water subsequent to making a pressure balance between the reactor and tank. At the early stages of the accident, the high flow rate of

  4. Performance Analysis of Multi Stage Safety Injection Tank

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Soo Jai; Kim, Young In; Bae, Youngmin; Kang, Han-Ok; Kim, Keung Koo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In general the integral reactor has such characteristics, the integral reactor requires a high flow rate of coolant safety injection at the initial stage of the accident in which the core level is relatively fast decreased, A medium flow rate of coolant safety injection at the early and middle stages of the accident in which the coolant discharge flow rate is relatively large due to a high internal pressure of the reactor vessel, and a low flow rate of coolant safety injection is required at the middle and late stages of the accident in which the coolant discharge flow rate is greatly reduced due to a decreased pressure of the reactor vessel. It is noted that a high flow rate of the integral reactor is quite smaller compared to a flow rate required in the commercial loop type reactor. However, a nitrogen pressurized safety injection tank has been typically designed to quickly inject a high flow rate of coolant when the internal pressure of the reactor vessel is rapidly decreased, and a core makeup tank has been designed to safely inject at a single mode flow rate due to a gravitational head of water subsequent to making a pressure balance between the reactor vessel and core makeup tank. As a result, in order to compensate such a disadvantage, various type systems are used in a complicated manner in a reactor according to the required characteristic of safety injection during an accident. In the present study, we have investigated numerically the performance of the multi stage safety injection tank. A parameter study has performed to understand the characteristics of the multi stage safety injection tank. The performance of the multi stage safety injection tank has been investigated numerically. When an accident occurs, the coolant in the multi stage safety injection tank is injected into a reactor vessel by a gravitational head of water subsequent to making a pressure balance between the reactor and tank. At the early stages of the accident, the high flow rate of

  5. 3D Polyaniline Architecture by Concurrent Inorganic and Organic Acid Doping for Superior and Robust High Rate Supercapacitor Performance

    Science.gov (United States)

    Gawli, Yogesh; Banerjee, Abhik; Dhakras, Dipti; Deo, Meenal; Bulani, Dinesh; Wadgaonkar, Prakash; Shelke, Manjusha; Ogale, Satishchandra

    2016-02-01

    A good high rate supercapacitor performance requires a fine control of morphological (surface area and pore size distribution) and electrical properties of the electrode materials. Polyaniline (PANI) is an interesting material in supercapacitor context because it stores energy Faradaically. However in conventional inorganic (e.g. HCl) acid doping, the conductivity is high but the morphological features are undesirable. On the other hand, in weak organic acid (e.g. phytic acid) doping, interesting and desirable 3D connected morphological features are attained but the conductivity is poorer. Here the synergy of the positive quality factors of these two acid doping approaches is realized by concurrent and optimized strong-inorganic (HCl) and weak-organic (phytic) acid doping, resulting in a molecular composite material that renders impressive and robust supercapacitor performance. Thus, a nearly constant high specific capacitance of 350 F g-1 is realized for the optimised case of binary doping over the entire range of 1 A g-1 to 40 A g-1 with stability of 500 cycles at 40 A g-1. Frequency dependant conductivity measurements show that the optimized co-doped case is more metallic than separately doped materials. This transport property emanates from the unique 3D single molecular character of such system.

  6. 3D Polyaniline Architecture by Concurrent Inorganic and Organic Acid Doping for Superior and Robust High Rate Supercapacitor Performance.

    Science.gov (United States)

    Gawli, Yogesh; Banerjee, Abhik; Dhakras, Dipti; Deo, Meenal; Bulani, Dinesh; Wadgaonkar, Prakash; Shelke, Manjusha; Ogale, Satishchandra

    2016-02-12

    A good high rate supercapacitor performance requires a fine control of morphological (surface area and pore size distribution) and electrical properties of the electrode materials. Polyaniline (PANI) is an interesting material in supercapacitor context because it stores energy Faradaically. However in conventional inorganic (e.g. HCl) acid doping, the conductivity is high but the morphological features are undesirable. On the other hand, in weak organic acid (e.g. phytic acid) doping, interesting and desirable 3D connected morphological features are attained but the conductivity is poorer. Here the synergy of the positive quality factors of these two acid doping approaches is realized by concurrent and optimized strong-inorganic (HCl) and weak-organic (phytic) acid doping, resulting in a molecular composite material that renders impressive and robust supercapacitor performance. Thus, a nearly constant high specific capacitance of 350 F g(-1) is realized for the optimised case of binary doping over the entire range of 1 A g(-1) to 40 A g(-1) with stability of 500 cycles at 40 A g(-1). Frequency dependant conductivity measurements show that the optimized co-doped case is more metallic than separately doped materials. This transport property emanates from the unique 3D single molecular character of such system.

  7. The use of quality control performance charts to analyze cesarean delivery rates nationally.

    LENUS (Irish Health Repository)

    Turner, Michael J

    2012-02-01

    OBJECTIVE: To examine the use of quality control performance charts to analyze cesarean rates nationally. METHODS: Information on cesarean rates was obtained for all 19 Irish maternity hospitals receiving state funding in 2009. All women who underwent cesarean delivery of a live or stillborn infant weighing 500 g or more between January 1 and December 31 were included. Deliveries were classified as elective or emergency. Individual hospitals were not identified in the analysis. RESULTS: The mean rates per hospital of elective and emergency cesarean were 12.9+\\/-2.6% (n=9337) and 13.8+\\/-3.0% (n=9989), respectively-giving an overall mean rate of 26.7+\\/-4.2% (n=19326) per hospital. Cesarean rates were normally distributed. Using a quality control performance chart with a cutoff 2 standard deviations from the mean, 1 hospital was above the normal range for both total and elective cesareans, indicating that its pre-labor obstetric practices warrant clinical review. Another hospital had a mean emergency cesarean rate above the normal range, indicating that its labor ward practices warrant review. CONCLUSION: Quality control performance charts can be used to analyze cesarean rates nationally and, thus, to identify hospitals at which obstetric practices should be reviewed.

  8. LATENT CLUSTER ANALYSIS OF INSTRUCTIONAL PRACTICES REPORTED BY HIGH- AND LOW-PERFORMING MATHEMATICS TEACHERS IN FOUR COUNTRIES

    Directory of Open Access Journals (Sweden)

    Qiang Cheng

    2017-06-01

    Full Text Available Using Trends in International Mathematics and Science Study (TIMSS 2011 eighth-grade international dataset, this study explored the profiles of instructional practices reported by high- and low-performing mathematics teachers across the US, Finland, Korea, and Russia. Concepts of conceptual teaching and procedural teaching were used to frame the design of the current study. Latent cluster analysis was applied in the investigation of the profiles of mathematics teachers’ instructional practices across the four education systems. It was found that all mathematics teachers in the high- and low-performing groups used procedurally as well as conceptually oriented practices in their teaching. However, one group of high-performing mathematics teachers from the U.S. sample and all the high-performing teachers from Finland, Korea, and Russia showed more frequent use of conceptually oriented practices than their corresponding low-performing teachers. Another group of U.S. high-performing mathematics teachers showed a distinctive procedurally oriented pattern, which presented a rather different picture. Such results provide useful suggestions for practitioners and policy makers in their effort to improve mathematics teaching and learning in the US and in other countries as well.DOI: http://dx.doi.org/10.22342/jme.8.2.4066.115-132

  9. High burn rate solid composite propellants

    Science.gov (United States)

    Manship, Timothy D.

    High burn rate propellants help maintain high levels of thrust without requiring complex, high surface area grain geometries. Utilizing high burn rate propellants allows for simplified grain geometries that not only make production of the grains easier, but the simplified grains tend to have better mechanical strength, which is important in missiles undergoing high-g accelerations. Additionally, high burn rate propellants allow for a higher volumetric loading which reduces the overall missile's size and weight. The purpose of this study is to present methods of achieving a high burn rate propellant and to develop a composite propellant formulation that burns at 1.5 inches per second at 1000 psia. In this study, several means of achieving a high burn rate propellant were presented. In addition, several candidate approaches were evaluated using the Kepner-Tregoe method with hydroxyl terminated polybutadiene (HTPB)-based propellants using burn rate modifiers and dicyclopentadiene (DCPD)-based propellants being selected for further evaluation. Propellants with varying levels of nano-aluminum, nano-iron oxide, FeBTA, and overall solids loading were produced using the HTPB binder and evaluated in order to determine the effect the various ingredients have on the burn rate and to find a formulation that provides the burn rate desired. Experiments were conducted to compare the burn rates of propellants using the binders HTPB and DCPD. The DCPD formulation matched that of the baseline HTPB mix. Finally, GAP-plasticized DCPD gumstock dogbones were attempted to be made for mechanical evaluation. Results from the study show that nano-additives have a substantial effect on propellant burn rate with nano-iron oxide having the largest influence. Of the formulations tested, the highest burn rate was a 84% solids loading mix using nano-aluminum nano-iron oxide, and ammonium perchlorate in a 3:1(20 micron: 200 micron) ratio which achieved a burn rate of 1.2 inches per second at 1000

  10. Performance of a constructed wetland treating intensive shrimp aquaculture wastewater under high hydraulic loading rate

    International Nuclear Information System (INIS)

    Lin, Y.-F.; Jing, S.-R.; Lee, D.-Y.; Chang, Y.-F.; Chen, Y.-M.; Shih, K.-C.

    2005-01-01

    A water treatment unit, mainly consisting of free water surface (FWS) and subsurface flow (SF) constructed wetland cells, was integrated into a commercial-scale recirculating aquaculture system for intensive shrimp culture. This study investigated performance of the treatment wetlands for controlling water quality. The results showed that the FWS-SF cells effectively removed total suspended solids (55-66%), 5-day biochemical oxygen demand (37-54%), total ammonia (64-66%) and nitrite (83-94%) from the recirculating water under high hydraulic loading rates (1.57-1.95 m/day). This led to a water quality that was suitable for shrimp culture and effluent that always satisfied the discharge standards. The area ratios of wetlands to culture tank being demonstrated (0.43) and calculated (0.096) in this study were both significantly lower than the reported values. Accordingly, a constructed wetland was technically and economically feasible for managing water quality of an intensive aquaculture system. - A constructed wetland was found to be technically and economically feasible for managing water quality of an intensive recirculating aquaculture system

  11. Internal Flow of Contra-Rotating Small Hydroturbine at Off- Design Flow Rates

    Science.gov (United States)

    SHIGEMITSU, Toru; TAKESHIMA, Yasutoshi; OGAWA, Yuya; FUKUTOMI, Junichiro

    2016-11-01

    Small hydropower generation is one of important alternative energy, and enormous potential lie in the small hydropower. However, efficiency of small hydroturbines is lower than that of large one. Then, there are demands for small hydroturbines to keep high performance in wide flow rate range. Therefore, we adopted contra-rotating rotors, which can be expected to achieve high performance. In this research, performance of the contra-rotating small hydroturbine with 60mm casing diameter was investigated by an experiment and numerical analysis. Efficiency of the contra-rotating small hydroturbine was high in pico-hydroturbine and high efficiency could be kept in wide flow rate range, however the performance of a rear rotor decreased significantly in partial flow rates. Then, internal flow condition, which was difficult to measure experimentally, was investigated by the numerical flow analysis. Then, a relation between the performance and internal flow condition was considered by the numerical analysis result.

  12. Parametric study and performance analysis of hybrid rocket motors with double-tube configuration

    Science.gov (United States)

    Yu, Nanjia; Zhao, Bo; Lorente, Arnau Pons; Wang, Jue

    2017-03-01

    The practical implementation of hybrid rocket motors has historically been hampered by the slow regression rate of the solid fuel. In recent years, the research on advanced injector designs has achieved notable results in the enhancement of the regression rate and combustion efficiency of hybrid rockets. Following this path, this work studies a new configuration called double-tube characterized by injecting the gaseous oxidizer through a head end injector and an inner tube with injector holes distributed along the motor longitudinal axis. This design has demonstrated a significant potential for improving the performance of hybrid rockets by means of a better mixing of the species achieved through a customized injection of the oxidizer. Indeed, the CFD analysis of the double-tube configuration has revealed that this design may increase the regression rate over 50% with respect to the same motor with a conventional axial showerhead injector. However, in order to fully exploit the advantages of the double-tube concept, it is necessary to acquire a deeper understanding of the influence of the different design parameters in the overall performance. In this way, a parametric study is carried out taking into account the variation of the oxidizer mass flux rate, the ratio of oxidizer mass flow rate injected through the inner tube to the total oxidizer mass flow rate, and injection angle. The data for the analysis have been gathered from a large series of three-dimensional numerical simulations that considered the changes in the design parameters. The propellant combination adopted consists of gaseous oxygen as oxidizer and high-density polyethylene as solid fuel. Furthermore, the numerical model comprises Navier-Stokes equations, k-ε turbulence model, eddy-dissipation combustion model and solid-fuel pyrolysis, which is computed through user-defined functions. This numerical model was previously validated by analyzing the computational and experimental results obtained for

  13. Relapse rates after psychotherapy for depression - stable long-term effects? A meta-analysis.

    Science.gov (United States)

    Steinert, Christiane; Hofmann, Mareike; Kruse, Johannes; Leichsenring, Falk

    2014-10-01

    Depression is the most common mental disorder. Effective psychotherapeutic treatments for depression exist; however, data on their long-term effectiveness beyond a time span of two years is still scarce. Our aim was to perform a meta-analysis, investigating (a) overall rates of relapse more than two years after psychotherapy (meta-analysis 1), and (b) if psychotherapy has more enduring effects than non-psychotherapeutic comparison conditions (e.g. pharmacotherapy, treatment as usual), again beyond a time span of two years post-therapy (meta-analysis 2). We searched electronic databases Medline, PsycINFO and the COCHRANE Library. Main selection criteria were (i) RCT of psychotherapy with follow-up interval of more than 2 years, (ii) primary diagnosis of depression, assessed by observer ratings, (iii) report of relapse at follow-up. We identified 11 studies, 6 of which included a non-psychotherapeutic comparison condition. Together they comprised long-term data of 966 patients. Mean follow-up duration was 4.4 years. The overall relapse rate at long-term follow-up was 0.39 (95% CI 0.29, 0.50). Psychotherapy resulted in significantly less relapses (53.1% vs. 71.1%, OR 0.51; 95% CI 0.32, 0.82, p=0.005) than comparison treatments. This finding corresponded to a number needed to treat (NNT) of 5.55. Results can only be preliminary as data was sparse and studies differed methodologically. Heterogeneity in the first meta-analysis was high (I(2)=82%). Results indicated publication bias. The relapse rate more than two years after psychotherapy is relatively high, but significantly lower compared to non-psychotherapeutic treatments. Multiannual follow-ups should routinely be included in future psychotherapy RCTs. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Analysis of production factors in high performance concrete

    Directory of Open Access Journals (Sweden)

    Gilberto Carbonari

    2003-01-01

    Full Text Available The incorporation of silica fume and superplasticizers in high strength and high performance concrete, along with a low water-cement ratio, leads to significant changes in the workability and the energy needed to homogenize and compact the concrete. Moreover, several aspects of concrete production that are not critical for conventional concrete are important for high strength concrete. This paper will discuss the need for controlling the humidity of the aggregates, optimizing the mixing sequence used in the fabrication, and the slump loss. The application of a silica fume concrete in typical building columns will be analyzed considering the required consolidation, the variability of the material strength within the structural element and the relation between core and molded specimen strength. Comparisons will also be made with conventional concrete.

  15. Analysis of aromatic aldehydes in brandy and wine by high-performance capillary electrophoresis.

    Science.gov (United States)

    Panossian, A; Mamikonyan, G; Torosyan, M; Gabrielyan, E; Mkhitaryan, S

    2001-09-01

    A new method of analysis of vanillin, syringaldehyde, coniferaldehyde, and sinapaldehyde in brandy and wine by high-performance capillary electrophoresis is described. Electrophoretic mobility of these compounds is achieved by a borate buffer at pH 9.3. At this pH, the sensitivity of UV detection of these phenolic aldehydes also increases. UV absorptions at 348, 362, 404, and 422 nm were selected for monitoring vanillin, syringaldehyde, coniferaldehyde, and sinapaldehyde, respectively. This procedure was performed simultaneously during one run using a diode array detector. Samples of brandy or wine were analyzed directly without concentration, extraction, or any other preliminary treatment of the test sample. The limits of detection were found to be 0.275, 0.1425, 0.1475, and 0.1975 ppm for syringaldehyde, coniferaldehyde, sinapaldehyde, and vanillin, respectively, which is acceptable for analysis of both brandy and wine aged in oak barrels. The method has been shown to be linear in a range from 0.3 to 57 mg/L. Recoveries ranged between 99.9% and 107.7% for all of the compounds tested. Repeatability and reproducibility of the method were high. The relative standard deviation was consequently approximately 3% and also between 4.47% and 6.89% for all tested compounds. The method is useful for the identification of counterfeit brandy, which is easy to recognize by the absence of sinapaldehyde, syringaldehyde, and coniferaldehyde, which are not detectable in false brandy.

  16. INL High Performance Building Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Jennifer D. Morton

    2010-02-01

    (LEED®) Green Building Rating System (LEED 2009). The document employs a two-level approach for high performance building at INL. The first level identifies the requirements of the Guiding Principles for Sustainable New Construction and Major Renovations, and the second level recommends which credits should be met when LEED Gold certification is required.

  17. Design and performance of SiPM-based readout of PbF 2 crystals for high-rate, precision timing applications

    International Nuclear Information System (INIS)

    Kaspar, J.; Fienberg, A.T.; Hertzog, D.W.; Huehn, M.A.; Kammel, P.; Khaw, K.S.; Peterson, D.A.; Smith, M.W.; Wechel, T.D. Van; Chapelain, A.; Gibbons, L.K.; Sweigart, D.A.; Ferrari, C.; Fioretti, A.; Gabbanini, C.; Venanzoni, G.; Iacovacci, M.; Mastroianni, S.; Giovanetti, K.; Gohn, W.

    2017-01-01

    We have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g - 2 experiment at Fermilab. The calorimeter absorber is an array of lead-fluoride crystals, which produces short-duration Cherenkov light. The detector sits in the high magnetic field of the muon storage ring. The SiPMs selected, and their accompanying custom electronics, must preserve the short pulse shape, have high quantum efficiency, be non-magnetic, exhibit gain stability under varying rate conditions, and cover a fairly large fraction of the crystal exit surface area. We describe an optimized design that employs the new-generation of thru-silicon via devices. The performance is documented in a series of bench and beam tests.

  18. PERFORMANCE TREND” AND “PERFORMANCE CURRENT” RATINGS BY ECONOMIC VALUE ADDED (EVA

    Directory of Open Access Journals (Sweden)

    ALEXANDRU BOGEANU

    2013-08-01

    Full Text Available The Economic Value Added (EVA is an index of “durable development.” It was proposed by the Stern-Stewart Office and represents the true economic profit of companies. A company reports economic profit only if thereported accounting profit is higher than the opportunity cost of equity. The authors of the EVA model (Stern-Stewart have also proposed the ways of restating the financial statements to get a “fair image” of the results, thuseliminating the “accounting distortions.”Based on the performance indexes calculated based on EVA and second-generation indexes relating toEVA, we calculated two types of rating: Rating Performance Current and Rating Performance Trend. The rating iscalculated by means of the percentiles technique and the results are split into 22 rating classes.The used database is Russell 3000.

  19. Performance Analysis of DPSK-OCDMA System for Optical Access Network

    Science.gov (United States)

    Islam, Monirul; Ahmed, N.; Aljunid, S. A.; Ali, Sharafat; Sayeed, S.; Sabri, Naseer

    2016-03-01

    In this research, the performance of optical code division multiple access (OCDMA) using differential phase shift keying (DPSK) has been compared with OCDMA On-Off Keying (OOK). This comparison took place in terms of bit error rate (BER) and receiver power where two bit rates (155 Mbps and 622 Mbps) have been used for this analysis. Using of OptiSystem 7.0 simulation, comparing eye diagram and optical spectrum alongside with BER and Rx power. It is found that OCDMA-DPSK performs better in comparison to OCDMA-OOK. The performance analysis also provides parameter for designing and development of an OCDMA system for optical access network using DPSK.

  20. Performance of a high repetition pulse rate laser system for in-gas-jet laser ionization studies with the Leuven laser ion source LISOL

    International Nuclear Information System (INIS)

    Ferrer, R.; Sonnenschein, V.T.; Bastin, B.; Franchoo, S.; Huyse, M.; Kudryavtsev, Yu.; Kron, T.; Lecesne, N.; Moore, I.D.; Osmond, B.; Pauwels, D.; Radulov, D.; Raeder, S.; Rens, L.

    2012-01-01

    The laser ionization efficiency of the Leuven gas cell-based laser ion source was investigated under on- and off-line conditions using two distinctly different laser setups: a low-repetition rate dye laser system and a high-repetition rate Ti:sapphire laser system. A systematic study of the ion signal dependence on repetition rate and laser pulse energy was performed in off-line tests using stable cobalt and copper isotopes. These studies also included in-gas-jet laser spectroscopy measurements on the hyperfine structure of 63 Cu. A final run under on-line conditions in which the radioactive isotope 59 Cu (T 1/2 = 81.5 s) was produced, showed a comparable yield of the two laser systems for in-gas-cell ionization. However, a significantly improved time overlap by using the high-repetition rate laser system for in-gas-jet ionization was demonstrated by an increase of the overall duty cycle, and at the same time, pointed to the need for a better shaped atomic jet to reach higher ionization efficiencies.

  1. [Analysis of the preservative chlorphenesin in cosmetics by high performance liquid chromatography].

    Science.gov (United States)

    Zhu, Huijuan; Zhang, Weiqiang; Yang, Yanwei; Zhu, Ying

    2014-01-01

    An analytical method was developed for the determination of the preservative of chlorphenesin in cosmetics by high performance liquid chromatography (HPLC). A C18 column (250 mm x 4.6 mm, 5 microm) and a photodiode array detector were used. The mobile phase was methanol-water (55:45, v/v) with a flow rate of 1.0 mL/min. The detection wavelength was set at 280 nm and the column temperature was 25 degrees C. The limit of detection was 3 ng. A good linear relationship was obtained between the peak area and the mass concentration of chlorphenesin in the range of 1 - 500 mg/L and the correlation coefficient was 1.000 0. The recoveries of chlorphenesin at different spiked levels were 99.0% - 103% with the relative standard deviations (RSD) chlorphenesin in cosmetics.

  2. RELATIONSHIPS BETWEEN HEART RATE AND PHYSIOLOGICAL PARAMETERS OF PERFORMANCE IN TOP-LEVEL WATER POLO PLAYERS

    Directory of Open Access Journals (Sweden)

    O. Galy

    2014-07-01

    Full Text Available The aim of this study was to measure the heart rate (HR response of eight elite water polo players during the four 7-min quarters of the game and to check for relationships with the physiological parameters of performance ( ·VO2max, Th1vent, Th2vent. Each athlete performed a ·VO2max treadmill test and played a water polo game wearing a heart rate monitor. The game fatigue index was calculated as the ratio of the fourth-quarter HR to the first-quarter HR: HR4/HR1. The results showed a slight decrease in fourth-quarter HR compared with the first quarter, with the mean four-quarter HR equal to 79.9 ± 4.2% of HRmax. Stepwise multiple regression analysis showed ·VO2max to be the main explanatory factor of game intensity, i.e. game HR expressed in %HRreserve (R=0.88, P<0.01. We observed that higher aerobic capacity resulted in higher game intensity. We also observed a decrease in the playing intensity in the fourth quarter compared with the first, likely due to very high game involvement. We concluded that high aerobic capacity seems necessary to ensure high game intensity in water polo. This suggests that coaches should encourage their athletes to reach a minimum level of ·VO2max and that HR monitoring could be of great interest in the control of water polo training sessions.

  3. Liquid Argon Calorimeter performance at High Rates

    CERN Document Server

    Seifert, F; The ATLAS collaboration

    2013-01-01

    The expected increase of luminosity at HL-LHC by a factor of ten with respect to LHC luminosities has serious consequences for the signal reconstruction, radiation hardness requirements and operations of the ATLAS liquid argon calorimeters in the endcap, respectively forward region. Small modules of each type of calorimeter have been built and exposed to a high intensity proton beam of 50 GeV at IHEP/Protvino. The beam is extracted via the bent crystal technique, offering the unique opportunity to cover intensities ranging from $10^6$ p/s up to $3\\cdot10^{11}$ p/s. This exceeds the deposited energy per time expected at HL-LHC by more than a factor of 100. The correlation between beam intensity and the read-out signal has been studied. The data show clear indications of pulse shape distortion due to the high ionization build-up, in agreement with MC expectations. This is also confirmed from the dependence of the HV currents on beam intensity.

  4. Evaluation of functioning of high dose rate brachytherapy at the Instituto Nacional do Cancer

    International Nuclear Information System (INIS)

    Guedes, Laura M.A.; Barreto, Rodrigo V.; Silva, Penha M.; Macedo, Afranio A.; Borges, Solange C.; Martinez, Valeria P.O.

    2001-01-01

    Quality control tests are very useful tools to assure the quality of patient's treatment. A daily control of the high dose rate micro selectron was performed based on the security parameters of the equipment and on the quickness of performance. The purpose of this report is to evaluate and to discuss the errors found during the first three years with the high dose rate brachytherapy, at the Instituto Nacional de Cancer. (author)

  5. Performance analysis of CDMA-based wireless communication

    African Journals Online (AJOL)

    move towards higher data transmission rates, however, a number of other ... performance with number of users, number ... SYSTEM MODEL AND ANALYSIS ..... If we now define Fk as the variable for the set of all integers in [0, N-2] for which ai ...

  6. Performance analysis: a study using data envelopment analysis in 26 Brazilian hospitals.

    Science.gov (United States)

    Guerra, Mariana; de Souza, Antônio Artur; Moreira, Douglas Rafael

    2012-01-01

    This article describes a proposal for analyzing the performance of public Brazilian hospitals using financial and non-financial rates (i.e., operational rates), and thereby highlights the effectiveness (or otherwise) of the financial management of organizations in this study. A total of 72 hospitals in the Brazilian Unified Health Care System (in Portuguese, Sistema Unico de Saúde-SUS), were selected for accessibility and completeness of their data. Twenty-six organizations were used for the study sample, consisting of entities that had publicly disclosed financial statements for the period from 2008 (in particular, via the Internet) and whose operational data could be found in the SUS database. Our proposal, based on models using the method of Data Envelopment Analysis (DEA), was the construction of six initial models that were later compiled into a standard model. The relations between the rates that comprised the models were based on the variables and the notes of: Schuhmann, McCue and Nayar, Barnum and Kutzin, Younis, Younies, and Okojie, Marinho, Moreno, and Cavalini, and Ersoy, Kavuncubasi, Ozcan, and Harris II. We put forward an enhanced grant proposal applicable to Brazil aiming to (i) confirm or refute the rates that show the effectiveness or ineffectiveness of financial management of national hospitals; and (ii) determine the best performances, which could be used as a reference for future studies. Obtained results: (i) for all financial indicators considered, only one showed no significance in all models; and (ii) for operational indicators, the results were not relevant when the number of occupied beds was considered. Though the analysis was related to only services provided by SUS, we conclude that our study has great potential for analyzing the financial management performance of Brazilian hospitals in general, for the following reasons: (i) it shows the relationship of financial and operational rates that can be used to analyze the performance of

  7. HIGH-PERFORMANCE COMPUTING FOR THE STUDY OF EARTH AND ENVIRONMENTAL SCIENCE MATERIALS USING SYNCHROTRON X-RAY COMPUTED MICROTOMOGRAPHY

    International Nuclear Information System (INIS)

    FENG, H.; JONES, K.W.; MCGUIGAN, M.; SMITH, G.J.; SPILETIC, J.

    2001-01-01

    Synchrotron x-ray computed microtomography (CMT) is a non-destructive method for examination of rock, soil, and other types of samples studied in the earth and environmental sciences. The high x-ray intensities of the synchrotron source make possible the acquisition of tomographic volumes at a high rate that requires the application of high-performance computing techniques for data reconstruction to produce the three-dimensional volumes, for their visualization, and for data analysis. These problems are exacerbated by the need to share information between collaborators at widely separated locations over both local and tide-area networks. A summary of the CMT technique and examples of applications are given here together with a discussion of the applications of high-performance computing methods to improve the experimental techniques and analysis of the data

  8. HIGH-PERFORMANCE COMPUTING FOR THE STUDY OF EARTH AND ENVIRONMENTAL SCIENCE MATERIALS USING SYNCHROTRON X-RAY COMPUTED MICROTOMOGRAPHY.

    Energy Technology Data Exchange (ETDEWEB)

    FENG,H.; JONES,K.W.; MCGUIGAN,M.; SMITH,G.J.; SPILETIC,J.

    2001-10-12

    Synchrotron x-ray computed microtomography (CMT) is a non-destructive method for examination of rock, soil, and other types of samples studied in the earth and environmental sciences. The high x-ray intensities of the synchrotron source make possible the acquisition of tomographic volumes at a high rate that requires the application of high-performance computing techniques for data reconstruction to produce the three-dimensional volumes, for their visualization, and for data analysis. These problems are exacerbated by the need to share information between collaborators at widely separated locations over both local and tide-area networks. A summary of the CMT technique and examples of applications are given here together with a discussion of the applications of high-performance computing methods to improve the experimental techniques and analysis of the data.

  9. Activated carbon derived from melaleuca barks for outstanding high-rate supercapacitors

    Science.gov (United States)

    Luo, Qiu-Ping; Huang, Liang; Gao, Xiang; Cheng, Yongliang; Yao, Bin; Hu, Zhimi; Wan, Jun; Xiao, Xu; Zhou, Jun

    2015-07-01

    Activated carbon (AC) was prepared via carbonizing melaleuca bark in an argon atmosphere at 600 °C followed with KOH activation for high-rate supercapacitors. This AC electrode has a high capacitance of 233 F g-1 at a scan rate of 2 mV s-1 and an excellent rate capability of ˜80% when increasing the sweep rate from 2 to 500 mV s-1. The symmetric supercapacitor assembled by the above electrode can deliver a high energy density of 4.2 Wh kg-1 with a power density of 1500 W kg-1 when operated in the voltage range of 0-1 V in 1 M H2SO4 aqueous electrolyte while maintaining great cycling stability (less than 5% capacitance loss after 10 000 cycles at sweep rate of 100 mV s-1). All the outstanding electrochemical performances make this AC electrode a promising candidate for potential energy storage application.

  10. High fusion performance at high T i/T e in JET-ILW baseline plasmas with high NBI heating power and low gas puffing

    Science.gov (United States)

    Kim, Hyun-Tae; Sips, A. C. C.; Romanelli, M.; Challis, C. D.; Rimini, F.; Garzotti, L.; Lerche, E.; Buchanan, J.; Yuan, X.; Kaye, S.; contributors, JET

    2018-03-01

    This paper presents the transport analysis of high density baseline discharges in the 2016 experimental campaign of the Joint European Torus with the ITER-Like Wall (JET-ILW), where a significant increase in the deuterium-deuterium (D-D) fusion neutron rate (~2.8  ×  1016 s-1) was achieved with stable high neutral beam injection (NBI) powers of up to 28 MW and low gas puffing. Increase in T i exceeding T e were produced for the first time in baseline discharges despite the high electron density; this enabled a significant increase in the thermal fusion reaction rate. As a result, the new achieved record in fusion performance was much higher than the previous record in the same heating power baseline discharges, where T i  =  T e. In addition to the decreases in collisionality and the increases in ion heating fraction in the discharges with high NBI power, T i  >  T e can also be attributed to positive feedback between the high T i/T e ratio and stabilisation of the turbulent heat flux resulting from the ion temperature gradient driven mode. The high T i/T e ratio was correlated with high rotation frequency. Among the discharges with identical beam heating power, higher rotation frequencies were observed when particle fuelling was provided by low gas puffing and pellet injection. This reveals that particle fuelling played a key role for achieving high T i/T e, and the improved fusion performance.

  11. HiTempo: a platform for time-series analysis of remote-sensing satellite data in a high-performance computing environment

    CSIR Research Space (South Africa)

    Van den Bergh, F

    2012-08-01

    Full Text Available Course resolution earth observation satellites offer large data sets with daily observations at global scales. These data sets represent a rich resource that, because of the high acquisition rate, allows the application of time-series analysis...

  12. Analysis of Factors that Influence Infiltration Rates using the HELP Model

    International Nuclear Information System (INIS)

    Dyer, J.; Shipmon, J.

    2017-01-01

    The Hydrologic Evaluation of Landfill Performance (HELP) model is used by Savannah River National Laboratory (SRNL) in conjunction with PORFLOW groundwater flow simulation software to make longterm predictions of the fate and transport of radionuclides in the environment at radiological waste sites. The work summarized in this report supports preparation of the planned 2018 Performance Assessment for the E-Area Low-Level Waste Facility (LLWF) at the Savannah River Site (SRS). More specifically, this project focused on conducting a sensitivity analysis of infiltration (i.e., the rate at which water travels vertically in soil) through the proposed E-Area LLWF closure cap. A sensitivity analysis was completed using HELP v3.95D to identify the cap design and material property parameters that most impact infiltration rates through the proposed closure cap for a 10,000-year simulation period. The results of the sensitivity analysis indicate that saturated hydraulic conductivity (Ksat) for select cap layers, precipitation rate, surface vegetation type, and geomembrane layer defect density are dominant factors limiting infiltration rate. Interestingly, calculated infiltration rates were substantially influenced by changes in the saturated hydraulic conductivity of the Upper Foundation and Lateral Drainage layers. For example, an order-of-magnitude decrease in Ksat for the Upper Foundation layer lowered the maximum infiltration rate from a base-case 11 inches per year to only two inches per year. Conversely, an order-of-magnitude increase in Ksat led to an increase in infiltration rate from 11 to 15 inches per year. This work and its results provide a framework for quantifying uncertainty in the radionuclide transport and dose models for the planned 2018 E-Area Performance Assessment. Future work will focus on the development of a nonlinear regression model for infiltration rate using Minitab 17® to facilitate execution of probabilistic simulations in the GoldSim® overall

  13. Analysis of Factors that Influence Infiltration Rates using the HELP Model

    Energy Technology Data Exchange (ETDEWEB)

    Dyer, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Shipmon, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-09-28

    The Hydrologic Evaluation of Landfill Performance (HELP) model is used by Savannah River National Laboratory (SRNL) in conjunction with PORFLOW groundwater flow simulation software to make longterm predictions of the fate and transport of radionuclides in the environment at radiological waste sites. The work summarized in this report supports preparation of the planned 2018 Performance Assessment for the E-Area Low-Level Waste Facility (LLWF) at the Savannah River Site (SRS). More specifically, this project focused on conducting a sensitivity analysis of infiltration (i.e., the rate at which water travels vertically in soil) through the proposed E-Area LLWF closure cap. A sensitivity analysis was completed using HELP v3.95D to identify the cap design and material property parameters that most impact infiltration rates through the proposed closure cap for a 10,000-year simulation period. The results of the sensitivity analysis indicate that saturated hydraulic conductivity (Ksat) for select cap layers, precipitation rate, surface vegetation type, and geomembrane layer defect density are dominant factors limiting infiltration rate. Interestingly, calculated infiltration rates were substantially influenced by changes in the saturated hydraulic conductivity of the Upper Foundation and Lateral Drainage layers. For example, an order-of-magnitude decrease in Ksat for the Upper Foundation layer lowered the maximum infiltration rate from a base-case 11 inches per year to only two inches per year. Conversely, an order-of-magnitude increase in Ksat led to an increase in infiltration rate from 11 to 15 inches per year. This work and its results provide a framework for quantifying uncertainty in the radionuclide transport and dose models for the planned 2018 E-Area Performance Assessment. Future work will focus on the development of a nonlinear regression model for infiltration rate using Minitab 17® to facilitate execution of probabilistic simulations in the GoldSim® overall

  14. High-performance liquid chromatographic analysis of anthraquinone compounds in the Laurera benguelensis

    Science.gov (United States)

    Manojlović, N.; Marković, Z.; Gritsanapan, W.; Boonpragob, K.

    2009-09-01

    A high-performance liquid chromatographic (HPLC) method has been developed for the characterization of anthraquinone metabolites in extracts of the lichen Laurera benguelensis. With this method four anthraquinone derivatives 1,8-dihydroxy-3-methoxy-6-methylanthraquinone, 1,8-dihydroxy-3-formyl-6-methoxyanthraquinone, 1,8-dihydroxy-3-hydroxymethyl-6-methoxy-anthraquinone and 1,3,8-trihyroxy-6-methylanthraquinone can be analyzed. Components of lichen were detected by characteristic ultraviolet spectra and relative retention times. This is first report of phytochemical analysis of L. benguelensis. Importance of this research is in recognizing some new source (lichen and its extracts) as a natural emplacement of antioxidants because oxidation with free radicals or autooxidation is big problem for preservation of food products.

  15. A facility for the test of large area muon chambers at high rates

    CERN Document Server

    Agosteo, S; Belli, G; Bonifas, A; Carabelli, V; Gatignon, L; Hessey, N P; Maggi, M; Peigneux, J P; Reithler, H; Silari, Marco; Vitulo, P; Wegner, M

    2000-01-01

    Operation of large area muon detectors at the future Large Hadron Collider (LHC) will be characterized by large sustained hit rates over the whole area, reaching the range of kHz/\\scm. We describe a dedicated test zone built at CERN to test the performance and the aging of the muon chambers currently under development. A radioactive source delivers photons causing the sustained rate of random hits, while a narrow beam of high energy muons is used to directly calibrate the detector performance. A system of remotely controlled lead filters serves to vary the rate of photons over four orders of magnitude, to allow the study of performance as a function of rate.

  16. A facility for the test of large-area muon chambers at high rates

    Energy Technology Data Exchange (ETDEWEB)

    Agosteo, S.; Altieri, S.; Belli, G.; Bonifas, A.; Carabelli, V.; Gatignon, L.; Hessey, N.; Maggi, M.; Peigneux, J.-P.; Reithler, H. E-mail: hans.reithler@cern.ch; Silari, M.; Vitulo, P.; Wegner, M

    2000-09-21

    Operation of large-area muon detectors at the future Large Hadron Collider (LHC) will be characterized by large sustained hit rates over the whole area, reaching the range of kHz cm{sup -2}. We describe a dedicated test zone built at CERN to test the performance and the aging of the muon chambers currently under development. A radioactive source delivers photons causing the sustained rate of random hits, while a narrow beam of high-energy muons is used to directly calibrate the detector performance. A system of remotely controlled lead filters serves to vary the rate of photons over four orders of magnitude, to allow the study of performance as a function of rate. (authors)

  17. High-Rate Strong-Signal Quantum Cryptography

    Science.gov (United States)

    Yuen, Horace P.

    1996-01-01

    Several quantum cryptosystems utilizing different kinds of nonclassical lights, which can accommodate high intensity fields and high data rate, are described. However, they are all sensitive to loss and both the high rate and the strong-signal character rapidly disappear. A squeezed light homodyne detection scheme is proposed which, with present-day technology, leads to more than two orders of magnitude data rate improvement over other current experimental systems for moderate loss.

  18. High performance computing environment for multidimensional image analysis.

    Science.gov (United States)

    Rao, A Ravishankar; Cecchi, Guillermo A; Magnasco, Marcelo

    2007-07-10

    The processing of images acquired through microscopy is a challenging task due to the large size of datasets (several gigabytes) and the fast turnaround time required. If the throughput of the image processing stage is significantly increased, it can have a major impact in microscopy applications. We present a high performance computing (HPC) solution to this problem. This involves decomposing the spatial 3D image into segments that are assigned to unique processors, and matched to the 3D torus architecture of the IBM Blue Gene/L machine. Communication between segments is restricted to the nearest neighbors. When running on a 2 Ghz Intel CPU, the task of 3D median filtering on a typical 256 megabyte dataset takes two and a half hours, whereas by using 1024 nodes of Blue Gene, this task can be performed in 18.8 seconds, a 478x speedup. Our parallel solution dramatically improves the performance of image processing, feature extraction and 3D reconstruction tasks. This increased throughput permits biologists to conduct unprecedented large scale experiments with massive datasets.

  19. Microwave-assisted preparation of Li3V2(PO4)3/C composite with high-rate capacity

    International Nuclear Information System (INIS)

    Yan, Ji; Mao, Wen-feng; Xie, Hui; Tang, Zhi-yuan; Yuan, Wei; Chen, Xue-cheng; Xu, Qiang; Ma, Li

    2012-01-01

    Highlights: ► High-rate Li 3 V 2 (PO 4 ) 3 /C is firstly reported via a microwave-assisted method. ► The reduced particle size is responsible for the improved high-rate performance. ► A discharge capacity of 100 mAh g −1 is obtained at 20 C charge–discharge rate. -- Abstract: A fast sol–gel assisted microwave heating approach has been developed for the synthesis of high-rate Li 3 V 2 (PO 4 ) 3 /C cathode material. This approach can synthesize Li 3 V 2 (PO 4 ) 3 /C particles with high purity and good crystallinity in 12 min at a low microwave power of 320 W. In the voltage range of 3.0–4.3 V, the obtained Li 3 V 2 (PO 4 ) 3 /C delivers a reversible discharge capacity of 100 mAh g −1 after 100 cycles at 20 °C, exhibiting excellent rate capability and cycling performance. The rate-recovery performance also suggests that the Li 3 V 2 (PO 4 ) 3 /C material possesses excellent structure stability after high-rate cycles, presenting excellent application value in high-power lithium ion batteries.

  20. Recruitment Methods and Show Rates to a Prostate Cancer Early Detection Program for High-Risk Men: A Comprehensive Analysis

    Science.gov (United States)

    Giri, Veda N.; Coups, Elliot J.; Ruth, Karen; Goplerud, Julia; Raysor, Susan; Kim, Taylor Y.; Bagden, Loretta; Mastalski, Kathleen; Zakrzewski, Debra; Leimkuhler, Suzanne; Watkins-Bruner, Deborah

    2009-01-01

    Purpose Men with a family history (FH) of prostate cancer (PCA) and African American (AA) men are at higher risk for PCA. Recruitment and retention of these high-risk men into early detection programs has been challenging. We report a comprehensive analysis on recruitment methods, show rates, and participant factors from the Prostate Cancer Risk Assessment Program (PRAP), which is a prospective, longitudinal PCA screening study. Materials and Methods Men 35–69 years are eligible if they have a FH of PCA, are AA, or have a BRCA1/2 mutation. Recruitment methods were analyzed with respect to participant demographics and show to the first PRAP appointment using standard statistical methods Results Out of 707 men recruited, 64.9% showed to the initial PRAP appointment. More individuals were recruited via radio than from referral or other methods (χ2 = 298.13, p < .0001). Men recruited via radio were more likely to be AA (p<0.001), less educated (p=0.003), not married or partnered (p=0.007), and have no FH of PCA (p<0.001). Men recruited via referrals had higher incomes (p=0.007). Men recruited via referral were more likely to attend their initial PRAP visit than those recruited by radio or other methods (χ2 = 27.08, p < .0001). Conclusions This comprehensive analysis finds that radio leads to higher recruitment of AA men with lower socioeconomic status. However, these are the high-risk men that have lower show rates for PCA screening. Targeted motivational measures need to be studied to improve show rates for PCA risk assessment for these high-risk men. PMID:19758657

  1. Development and validation of a dissolution test with reversed-phase high performance liquid chromatographic analysis for Candesartan cilexetil in tablet dosage forms

    Directory of Open Access Journals (Sweden)

    Vairappan Kamalakkannan

    2016-09-01

    Full Text Available A simple, rapid, selective and reproducible reversed-phase high performance liquid chromatographic (RP-HPLC method has been developed and validated for the estimation of release of Candesartan cilexetil (CC in tablets. Analysis was performed on an Agilent, Zorbax C8 column (150mm × 4.6mm, 5μm with the mobile phase consisting of phosphate buffer (pH2.5–acetonitrile (15:85, v/v at a flow rate of 1.0mL/min. UV detection was performed at 215nm and the retention time for CC was 2.2. The calibration curve was linear (correlation coefficient = 1.000 in the selected range of analyte. The optimized dissolution conditions include the USP apparatus 2 at a paddle rotation rate of 50rpm and 900mL of phosphate buffer (pH7.2 with 0.03% of polysorbate 80 as dissolution medium, at 37.0 ± 0.5°C. The method was validated for precision, linearity, specificity, accuracy, limit of quantitation and ruggedness. The system suitability parameters, such as theoretical plate, tailing factor and relative standard deviation (RSD between six standard replicates were well within the limits. The stability result shows that the drug is stable in the prescribed dissolution medium. Three different batches (A, B and C of the formulation containing 8mg of Candesartan cilexetil was performed with the developed method and the results showed no significant differences among the batches.

  2. Customer and performance rating in QFD using SVM classification

    Science.gov (United States)

    Dzulkifli, Syarizul Amri; Salleh, Mohd Najib Mohd; Leman, A. M.

    2017-09-01

    In a classification problem, where each input is associated to one output. Training data is used to create a model which predicts values to the true function. SVM is a popular method for binary classification due to their theoretical foundation and good generalization performance. However, when trained with noisy data, the decision hyperplane might deviate from optimal position because of the sum of misclassification errors in the objective function. In this paper, we introduce fuzzy in weighted learning approach for improving the accuracy of Support Vector Machine (SVM) classification. The main aim of this work is to determine appropriate weighted for SVM to adjust the parameters of learning method from a given set of noisy input to output data. The performance and customer rating in Quality Function Deployment (QFD) is used as our case study to determine implementing fuzzy SVM is highly scalable for very large data sets and generating high classification accuracy.

  3. High frame-rate neutron radiography of dynamic events

    International Nuclear Information System (INIS)

    Bossi, R.H.; Robinson, A.H.; Barton, J.P.

    1981-01-01

    A system has been developed to perform neutron radiographic analysis of dynamic events having a duration of several milliseconds. The system has been operated in the range of 2000 to 10,000 frames/second. Synchronization has provided high-speed-motion neutron radiographs for evaluation of the firing cycle of 7.62 mm munition rounds within a steel rifle barrel. The system has also been used to demonstrate the ability to produce neutron radiographic movies of two-phase flow. The equipment uses the Oregon State University TRIGA reactor capable of pulsing to 3000 MW peak power, a neutron beam collimator, a scintillator neutron conversion screen coupled to an image intensifier, and a 16 mm high speed movie camera. The peak neutron flux incident at the object position is approximately 4 x 10 11 n/cm 2 s with a pulse, full width at half maximum, of 9 ms. Special studies have been performed on the scintillator conversion screens and on the effects of statistical limitations on the image quality. Modulation transfer function analysis has been used to assist in the evaluation of the system performance

  4. High frame-rate neutron radiography of dynamic events

    International Nuclear Information System (INIS)

    Bossi, R.H.; Robinson, A.H.; Barton, J.P.

    1983-01-01

    A system has been developed to perform neutron radiographic analysis of dynamic events having a duration of several milliseconds. The system has been operated in the range of 2000 to 10,000 frames/second. Synchronization has provided high-speed-motion neutron radiographs for evaluation of the firing cycle of 7.62 mm munition rounds within a steel rifle barrel. The system has also been used to demonstrate the ability to produce neutron radiographic movies of two phase flow. The equipment uses the Oregon State University TRIGA reactor capable of pulsing to 3000 MW peak power, a neutron beam collimator, a scintillator neutron conversion screen coupled to an image intensifier, and a 16 mm high speed movie camera. The peak neutron flux incident at the object position is approximately 4 x 10 11 n/cm 2 s with a pulse, full width at half maximum, of 9 ms. Special studies have been performed on the scintillator conversion screens and on the effects of statistical limitations on the image quality. Modulation transfer function analysis has been used to assist in the evaluation of the system performance. (Auth.)

  5. Rapid startup and high rate nitrogen removal from anaerobic sludge digester liquor using a SNAP process.

    Science.gov (United States)

    Qiao, Sen; Nishiyama, Takashi; Fujii, Tatsuo; Bhatti, Zafar; Furukawa, Kenji

    2012-02-01

    In this study, a single-stage autotrophic nitrogen removal reactor, packed with a novel acrylic fiber biomass carrier material (Biofix), was applied for nitrogen removal from sludge digester liquor. For rapid start-up, conventional activated sludge was added to the reactor soon after the attachment of anammox biomass on the Biofix carriers, which allowed conventional activated sludge to form a protective layer of biofilm around the anammox biomass. The Nitrogen removal efficiency reached 75% within 1 week at a nitrogen loading rate of 0.46 kg-N/m(3)/day for synthetic wastewater treatment. By the end of the synthetic wastewater treatment period, the maximum nitrogen removal rate had increased to 0.92 kg-N/m(3)/day at a nitrogen loading rate of 1.0 kg-N/m(3)/day. High nitrogen removal rate was also achieved during the actual raw digester liquor treatment with the highest nitrogen removal rate being 0.83 kg-N/m(3)/day at a nitrogen loading rate of 0.93 kg-N/m(3)/day. The thick biofilm on Biofix carriers allowed anammox bacteria to survive under high DO concentration of 5-6 mg/l resulting in stable and high nitrogen removal performance. FISH and CLSM analysis demonstrated that anammox bacteria coexisted and surrounded by ammonium oxidizing bacteria.

  6. Rate of familial amyotrophic lateral sclerosis: a systematic review and meta-analysis.

    LENUS (Irish Health Repository)

    Byrne, Susan

    2010-11-03

    Background The population rate of familial amyotrophic lateral sclerosis (FALS) is frequently reported as 10%. However, a systematic review and meta-analysis of the true population based frequency of FALS has never been performed. Method A Medline literature review identified all original articles reporting a rate of FALS. Studies were grouped according to the type of data presented and examined for sources of case ascertainment. A systematic review and meta-analysis of reported rates of FALS was then conducted to facilitate comparison between studies and calculate a pooled rate of FALS. Results 38 papers reported a rate of FALS. Thirty-three papers were included in analysis and the rate of FALS for all studies was 4.6% (95% CI 3.9% to 5.5%). Restricting the analysis to prospective population based registry data revealed a rate of 5.1% (95% CI 4.1% to 6.1%). The incidence of FALS was lower in southern Europe. There was no correlation between rate of FALS and reported SOD1 mutation rates. Conclusion The rate of FALS among prospective population based registries is 5.1% (CI 4.1 to 6.1%), and not 10% as is often stated. Further detailed prospective population based studies of familial ALS are required to confirm this rate.

  7. Rate of familial amyotrophic lateral sclerosis: a systematic review and meta-analysis.

    LENUS (Irish Health Repository)

    Byrne, Susan

    2012-02-01

    BACKGROUND: The population rate of familial amyotrophic lateral sclerosis (FALS) is frequently reported as 10%. However, a systematic review and meta-analysis of the true population based frequency of FALS has never been performed. METHOD: A Medline literature review identified all original articles reporting a rate of FALS. Studies were grouped according to the type of data presented and examined for sources of case ascertainment. A systematic review and meta-analysis of reported rates of FALS was then conducted to facilitate comparison between studies and calculate a pooled rate of FALS. RESULTS: 38 papers reported a rate of FALS. Thirty-three papers were included in analysis and the rate of FALS for all studies was 4.6% (95% CI 3.9% to 5.5%). Restricting the analysis to prospective population based registry data revealed a rate of 5.1% (95% CI 4.1% to 6.1%). The incidence of FALS was lower in southern Europe. There was no correlation between rate of FALS and reported SOD1 mutation rates. CONCLUSION: The rate of FALS among prospective population based registries is 5.1% (CI 4.1 to 6.1%), and not 10% as is often stated. Further detailed prospective population based studies of familial ALS are required to confirm this rate.

  8. Increased effects of machining damage in beryllium observed at high strain rates

    International Nuclear Information System (INIS)

    Beitscher, S.; Brewer, A.W.; Corle, R.R.

    1980-01-01

    Tensile tests at both low and high strain rates, and also impact shear tests, were performed on a weldable grade powder-source beryllium. Impact energies increased by a factor of 2 to 3 from the as-machined level after etching or annealing. Similar increases in the ductility from machining damage removal were observed from the tensile data at the higher strain rate (10 s -1 ) while an insignificant increase in elongation was measured at the lower strain rate (10 -4 s -1 ). High strain-rate tests appear to be more sensitive and reliable for evaluating machining practice and damage removal methods for beryllium components subjected to sudden loads. 2 tables

  9. Performance analysis of conceptual waste package designs in salt repositories

    International Nuclear Information System (INIS)

    Jansen, G. Jr.; Raines, G.E.; Kircher, J.F.

    1984-01-01

    A performance analysis of commercial high-level waste and spent fuel conceptual package designs in reference repositories in three salt formations was conducted with the WAPPA waste package code. Expected conditions for temperature, stress, brine composition, radiation level, and brine flow rate were used as boundary conditions to compute expected corrosion of a thick-walled overpack of 1025 wrought steel. In all salt formations corrosion by low Mg salt-dissolution brines typical of intrusion scenarios was too slow to cause the package to fail for thousands of years after burial. In high Mg brines judged typical of thermally migrating brines in bedded salt formations, corrosion rates which would otherwise have caused the packages to fail within a few hundred years were limited by brine availability. All of the brine reaching the package was consumed by reaction with the iron in the overpack, thus preventing further corrosion. Uniform brine distribution over the package surface was an important factor in predicting long package lifetimes for the high Mg brines. 14 references, 15 figures

  10. High-performance mass storage system for workstations

    Science.gov (United States)

    Chiang, T.; Tang, Y.; Gupta, L.; Cooperman, S.

    1993-01-01

    Reduced Instruction Set Computer (RISC) workstations and Personnel Computers (PC) are very popular tools for office automation, command and control, scientific analysis, database management, and many other applications. However, when using Input/Output (I/O) intensive applications, the RISC workstations and PC's are often overburdened with the tasks of collecting, staging, storing, and distributing data. Also, by using standard high-performance peripherals and storage devices, the I/O function can still be a common bottleneck process. Therefore, the high-performance mass storage system, developed by Loral AeroSys' Independent Research and Development (IR&D) engineers, can offload a RISC workstation of I/O related functions and provide high-performance I/O functions and external interfaces. The high-performance mass storage system has the capabilities to ingest high-speed real-time data, perform signal or image processing, and stage, archive, and distribute the data. This mass storage system uses a hierarchical storage structure, thus reducing the total data storage cost, while maintaining high-I/O performance. The high-performance mass storage system is a network of low-cost parallel processors and storage devices. The nodes in the network have special I/O functions such as: SCSI controller, Ethernet controller, gateway controller, RS232 controller, IEEE488 controller, and digital/analog converter. The nodes are interconnected through high-speed direct memory access links to form a network. The topology of the network is easily reconfigurable to maximize system throughput for various applications. This high-performance mass storage system takes advantage of a 'busless' architecture for maximum expandability. The mass storage system consists of magnetic disks, a WORM optical disk jukebox, and an 8mm helical scan tape to form a hierarchical storage structure. Commonly used files are kept in the magnetic disk for fast retrieval. The optical disks are used as archive

  11. Teacher Performance Trajectories in High- and Lower-Poverty Schools

    Science.gov (United States)

    Xu, Zeyu; Özek, Umut; Hansen, Michael

    2015-01-01

    This study explores whether teacher performance trajectory over time differs by school-poverty settings. Focusing on elementary school mathematics teachers in North Carolina and Florida, we find no systematic relationship between school student poverty rates and teacher performance trajectories. In both high- (=60% free/reduced-price lunch [FRPL])…

  12. High-rate capability of lithium-ion batteries after storing at elevated temperature

    International Nuclear Information System (INIS)

    Wu, Mao-Sung; Chiang, Pin-Chi Julia

    2007-01-01

    High-rate performances of a lithium-ion battery after storage at elevated temperature are investigated electrochemically by means of three-electrode system. The high-rate capability is decreased significantly after high-temperature storage. A 3 C discharge capacities after room-temperature storage and 60 o C storage are 650 and 20 mAh, respectively. Lithium-ion diffusion in lithium cobalt oxide cathode limits the battery's capacity and the results show that storage temperature changes this diffusion behavior. Transmission electron microscopy (TEM) images show that many defects are directly observed in the cathode after storage compared with the fresh cathode; the structural defects block the diffusion within the particles. Electrochemical impedance and polarization curve indicate that mass-transfer (diffusion) dominates the discharge capacity during high-rate discharge

  13. Energy absorption at high strain rate of glass fiber reinforced mortars

    Directory of Open Access Journals (Sweden)

    Fenu Luigi

    2015-01-01

    Full Text Available In this paper, the dynamic behaviour of cement mortars reinforced with glass fibers was studied. The influence of the addition of glass fibers on energy absorption and tensile strength at high strain-rate was investigated. Static tests in compression, in tension and in bending were first performed. Dynamic tests by means of a Modified Hopkinson Bar were then carried out in order to investigate how glass fibers affected energy absorption and tensile strength at high strain-rate of the fiber reinforced mortar. The Dynamic Increase Factor (DIF was finally evaluated.

  14. INTEREST RATE REGIME AND THE PERFORMANCE OF THE NIGERIAN CAPITAL MARKET

    Directory of Open Access Journals (Sweden)

    Edirin Jeroh

    2015-12-01

    Full Text Available This study x-ray’s the interest rates regime in Nigeria as it affects the performance of the Nigerian Capital Market. In order to achieve this objective, relevant data for a period of 33 years spanning from 1981 – 2013 were obtained from the Factbook of the Nigerian Stock Exchange, CBN Statistical Bulletin as well as the annual accounts of quoted firms for the relevant years. The data obtained were analysed with the Ordinary Least Square (OLS technique. The result from our analysis reveal among others that changes in interest rate regimes have majorly influenced the level of the performance of the Nigerian Capital Market. Based on the above, we recommend that capital market regulators and other regulatory agencies should keep an eye on movements in interest rates and the Minimum Rediscount Rate (MRR (now MPR and watch their trend. We also recommend that efforts must be put in place to establish a policy review and reassessment mechanism that would help in assessing the impact of selected policy measures on the economy so that policy makers would know the effectiveness and efficiency of designed policies and be guided in the policy review and development process in the country.

  15. Determination of the survival rate in patients with congestive heart failure stratified by 123I-MIBG imaging. A meta-analysis from the studies performed in Japan

    International Nuclear Information System (INIS)

    Kuwabara, Yoichi; Tamaki, Nagara; Nakata, Tomoaki; Yamashina, Shohei; Yamazaki, Junichi

    2011-01-01

    The goals of this meta-analysis were to determine survival rates in patients with heart failure (HF) assessed by 123 I-metaiodobenzylguanidine (MIBG) imaging results using recently published studies and to determine the prognostic value of 123 I-MIBG imaging. We reviewed published cohort studies carried out in Japan that compared the prognosis of patients with their 123 I-MIBG activity quantified as late heart-to-mediastinum ratio (H/M) or washout rate by performing a PubMed search for articles in English up to December 2006. Studies were selected if they analyzed a clearly defined lethal outcome (cardiovascular death) using life tables to estimate the odds ratio at 24 months after enrollment. Of 158 articles related to cardiac 123 I-MIBG, seven referred to studies that met the inclusion criteria: 5 evaluated H/M via 123 I-MIBG in a total of 866 patients and 4 calculated washout rate in a total of 491 patients. A low H/M indicated a high risk of cardiac death: pooled odds ratio, 5.2; 95% confidence interval (CI) of 3.1-5.7. A high washout was also associated with lethal events with a pooled odds ratio of 2.8 (CI: 1.6-5.0). The association between washout and cardiac death was heterogeneous (Chi-square=11.0, P 123 I-MIBG studies conducted in Japan indicated that both a decreased cardiac 123 I-MIBG activity (H/M) and an increased washout rate are indicative of a poor prognosis in patients with chronic heart failure. (author)

  16. Effect of exposure to good vs poor medical trainee performance on attending physician ratings of subsequent performances.

    Science.gov (United States)

    Yeates, Peter; O'Neill, Paul; Mann, Karen; Eva, Kevin W

    2012-12-05

    Competency-based models of education require assessments to be based on individuals' capacity to perform, yet the nature of human judgment may fundamentally limit the extent to which such assessment is accurately possible. To determine whether recent observations of the Mini Clinical Evaluation Exercise (Mini-CEX) performance of postgraduate year 1 physicians influence raters' scores of subsequent performances, consistent with either anchoring bias (scores biased similar to previous experience) or contrast bias (scores biased away from previous experience). Internet-based randomized, blinded experiment using videos of Mini-CEX assessments of postgraduate year 1 trainees interviewing new internal medicine patients. Participants were 41 attending physicians from England and Wales experienced with the Mini-CEX, with 20 watching and scoring 3 good trainee performances and 21 watching and scoring 3 poor performances. All then watched and scored the same 3 borderline video performances. The study was completed between July and November 2011. The primary outcome was scores assigned to the borderline videos, using a 6-point Likert scale (anchors included: 1, well below expectations; 3, borderline; 6, well above expectations). Associations were tested in a multivariable analysis that included participants' sex, years of practice, and the stringency index (within-group z score of initial 3 ratings). The mean rating scores assigned by physicians who viewed borderline video performances following exposure to good performances was 2.7 (95% CI, 2.4-3.0) vs 3.4 (95% CI, 3.1-3.7) following exposure to poor performances (difference of 0.67 [95% CI, 0.28-1.07]; P = .001). Borderline videos were categorized as consistent with failing scores in 33 of 60 assessments (55%) in those exposed to good performances and in 15 of 63 assessments (24%) in those exposed to poor performances (P performances compared with 25 of 63 assessments (39.5%) in those exposed to poor performances (P poor

  17. Analog circuit design designing high performance amplifiers

    CERN Document Server

    Feucht, Dennis

    2010-01-01

    The third volume Designing High Performance Amplifiers applies the concepts from the first two volumes. It is an advanced treatment of amplifier design/analysis emphasizing both wideband and precision amplification.

  18. High-rate polyaniline/carbon-cloth electrodes: effect of mass loading on the pseudocapacitive performance

    Czech Academy of Sciences Publication Activity Database

    Tomšík, Elena; Ivanko, Iryna; Kohut, Olena; Hromádková, Jiřina

    2017-01-01

    Roč. 4, č. 11 (2017), s. 2884-2890 ISSN 2196-0216 R&D Projects: GA ČR(CZ) GA15-14791S Grant - others:OPPK(XE) CZ.2.16/3.1.00/21545 Program:OPPK Institutional support: RVO:61389013 Keywords : pseudocapacitors * polyaniline * high charge-discharge rate Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 4.136, year: 2016

  19. Regulation and drive system for high rep-rate magnetic-pulse compressors

    International Nuclear Information System (INIS)

    Birx, D.L.; Cook, E.G.; Hawkins, S.; Meyers, A.; Reginato, L.L.; Schmidt, J.A.; Smith, M.W.

    1982-01-01

    The essentially unlimited rep-rate capability of non-linear magnetic systems has imposed strict requirements on the drive system which initiates the pulse compression. An order of magnitude increase in the rep-rates achieved by the Advanced Test Accelerator (ATA) gas blown system is not difficult to achieve in the magnetic compressor. The added requirement of having a high degree of regulation at the higher rep-rates places strict requirements on the triggerable switch for charging and de-Queing. A novel feedback technique which applies the proper bias to a magnetic core by comparing a reference voltage to the charging voltage eases considerably the regulation required to achieve low jitter in magnetic compression. The performance of the high rep-rate charging and regulation systems will be described in the following pages

  20. Analysis of human milk oligosaccharides using high-performance anion-exchange chromatography with pulsed amperometric detection

    DEFF Research Database (Denmark)

    Lie, Aleksander; Pedersen, Lars Haastrup

    ) and lacto-N-neotetraose (Galβ1-4GlcNAcβ1-3Galβ1-4Glc), among others. High-performance anion-exchange chromatography (HPAE) with pulsed amperometric detection (PAD) is an analysis method highly suited for carbohydrates. HPAE with alkaline eluents results in retention of neutral carbohydrates depending...... on the number of charged group in the molecule, pH and concentration of competing anions, while the PAD has sensitivity for carbohydrates in the pmol-range (Lee 1990). As a basis for the development and optimisation of HPAE elution methods, the parameter space was investigated in terms of eluent concentrations...

  1. The Effects of Performance Budgeting and Funding Programs on Graduation Rate in Public Four-Year Colleges and Universities

    Directory of Open Access Journals (Sweden)

    Jung-cheol Shinn

    2004-05-01

    Full Text Available This study was conducted to determine whether states with performance budgeting and funding (PBF programs had improved institutional performance of higher education over the five years (1997 through 2001 considered in this study. First Time in College (FTIC graduation rate was used as the measure of institutional performance. In this study, the unit of analysis is institution level and the study population is all public four-or-more-year institutions in the United States. To test PBF program effectiveness, Hierarchical Linear Modeling (HLM growth analysis was applied. According to the HLM analysis, the growth of graduation rates in states with PBF programs was not greater than in states without PBF programs. The lack of growth in institutional graduation rates, however, does not mean that PBF programs failed to achieve their goals. Policy-makers are advised to sustain PBF programs long enough until such programs bear their fruits or are proven ineffective.

  2. Effects of organic loading rates on reactor performance and microbial community changes during thermophilic aerobic digestion process of high-strength food wastewater.

    Science.gov (United States)

    Jang, Hyun Min; Lee, Jae Won; Ha, Jeong Hyub; Park, Jong Moon

    2013-11-01

    To evaluate the applicability of single-stage thermophilic aerobic digestion (TAD) process treating high-strength food wastewater (FWW), TAD process was operated at four organic loading rates (OLRs) from 9.2 to 37.2 kg COD/m(3)d. The effects of OLRs on microbial community changes were also examined. The highest volumetric removal rate (13.3 kg COD/m(3)d) and the highest thermo-stable protease activity (0.95 unit/mL) were detected at OLR=18.6 kg COD/m(3)d. Denaturing gradient gel electrophoresis (DGGE) profiles and quantitative PCR (qPCR) results showed significant microbial community shifts in response to changes in OLR. In particular, DGGE and phylogenetic analysis demonstrate that the presence of Bacillus sp. (phylum of Firmicutes) was strongly correlated with efficient removal of organic particulates from high-strength food wastewater. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. High Performance Liquid Chromatography-mass Spectrometry Analysis of High Antioxidant Australian Fruits with Antiproliferative Activity Against Cancer Cells.

    Science.gov (United States)

    Sirdaarta, Joseph; Maen, Anton; Rayan, Paran; Matthews, Ben; Cock, Ian Edwin

    2016-05-01

    145 unique mass signals were detected in the lemon aspen methanolic and aqueous extracts by nonbiased high-performance liquid chromatography-mass spectrometry analysis. Of these, 20 compounds were identified as being of particular interest due to their reported antioxidant and/or anticancer activities. The lack of toxicity and antiproliferative activity of the high antioxidant plant extracts against HeLa and CaCo2 cancer cell lines indicates their potential in the treatment and prevention of some cancers. Australian fruit extracts with high antioxidant contents were potent inhibitors of CaCo2 and HeLa carcinoma cell proliferationMethanolic lemon aspen extract was particularly potent, with IC50 values of 480 μg/mL (HeLa) and 769 μg/mL (CaCo2)High-performance liquid chromatography-mass spectrometry-quadrupole time-of-flight analysis highlighted and putatively identified 20 compounds in the antiproliferative lemon aspen extractsIn contrast, lower antioxidant content extracts stimulated carcinoma cell proliferationAll extracts with antiproliferative activity were nontoxic in the Artemia nauplii assay. Abbreviations used: DPPH: di (phenyl)- (2,4,6-trinitrophenyl) iminoazanium, HPLC: High-performance liquid chromatography, IC50: The concentration required to inhibit by 50%, LC50: The concentration required to achieve 50% mortality, MS: Mass spectrometry.

  4. High Performance Liquid Chromatography-mass Spectrometry Analysis of High Antioxidant Australian Fruits with Antiproliferative Activity Against Cancer Cells

    Science.gov (United States)

    Sirdaarta, Joseph; Maen, Anton; Rayan, Paran; Matthews, Ben; Cock, Ian Edwin

    2016-01-01

    g/mL). All other extracts were nontoxic. A total of 145 unique mass signals were detected in the lemon aspen methanolic and aqueous extracts by nonbiased high-performance liquid chromatography-mass spectrometry analysis. Of these, 20 compounds were identified as being of particular interest due to their reported antioxidant and/or anticancer activities. Conclusions: The lack of toxicity and antiproliferative activity of the high antioxidant plant extracts against HeLa and CaCo2 cancer cell lines indicates their potential in the treatment and prevention of some cancers. SUMMARY Australian fruit extracts with high antioxidant contents were potent inhibitors of CaCo2 and HeLa carcinoma cell proliferationMethanolic lemon aspen extract was particularly potent, with IC50 values of 480 μg/mL (HeLa) and 769 μg/mL (CaCo2)High-performance liquid chromatography-mass spectrometry-quadrupole time-of-flight analysis highlighted and putatively identified 20 compounds in the antiproliferative lemon aspen extractsIn contrast, lower antioxidant content extracts stimulated carcinoma cell proliferationAll extracts with antiproliferative activity were nontoxic in the Artemia nauplii assay. Abbreviations used: DPPH: di (phenyl)- (2,4,6-trinitrophenyl) iminoazanium, HPLC: High-performance liquid chromatography, IC50: The concentration required to inhibit by 50%, LC50: The concentration required to achieve 50% mortality, MS: Mass spectrometry. PMID:27279705

  5. Scaling of black silicon processing time by high repetition rate femtosecond lasers

    Directory of Open Access Journals (Sweden)

    Nava Giorgio

    2013-11-01

    Full Text Available Surface texturing of silicon substrates is performed by femtosecond laser irradiation at high repetition rates. Various fabrication parameters are optimized in order to achieve very high absorptance in the visible region from the micro-structured silicon wafer as compared to the unstructured one. A 70-fold reduction of the processing time is demonstrated by increasing the laser repetition rate from 1 kHz to 200 kHz. Further scaling up to 1 MHz can be foreseen.

  6. Classification of the medicinal plants of the genus Atractylodes using high-performance liquid chromatography with diode array and tandem mass spectrometry detection combined with multivariate statistical analysis.

    Science.gov (United States)

    Cho, Hyun-Deok; Kim, Unyong; Suh, Joon Hyuk; Eom, Han Young; Kim, Junghyun; Lee, Seul Gi; Choi, Yong Seok; Han, Sang Beom

    2016-04-01

    Analytical methods using high-performance liquid chromatography with diode array and tandem mass spectrometry detection were developed for the discrimination of the rhizomes of four Atractylodes medicinal plants: A. japonica, A. macrocephala, A. chinensis, and A. lancea. A quantitative study was performed, selecting five bioactive components, including atractylenolide I, II, III, eudesma-4(14),7(11)-dien-8-one and atractylodin, on twenty-six Atractylodes samples of various origins. Sample extraction was optimized to sonication with 80% methanol for 40 min at room temperature. High-performance liquid chromatography with diode array detection was established using a C18 column with a water/acetonitrile gradient system at a flow rate of 1.0 mL/min, and the detection wavelength was set at 236 nm. Liquid chromatography with tandem mass spectrometry was applied to certify the reliability of the quantitative results. The developed methods were validated by ensuring specificity, linearity, limit of quantification, accuracy, precision, recovery, robustness, and stability. Results showed that cangzhu contained higher amounts of atractylenolide I and atractylodin than baizhu, and especially atractylodin contents showed the greatest variation between baizhu and cangzhu. Multivariate statistical analysis, such as principal component analysis and hierarchical cluster analysis, were also employed for further classification of the Atractylodes plants. The established method was suitable for quality control of the Atractylodes plants. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Ultra-high-performance liquid chromatography/tandem high-resolution mass spectrometry analysis of sixteen red beverages containing carminic acid: identification of degradation products by using principal component analysis/discriminant analysis.

    Science.gov (United States)

    Gosetti, Fabio; Chiuminatto, Ugo; Mazzucco, Eleonora; Mastroianni, Rita; Marengo, Emilio

    2015-01-15

    The study investigates the sunlight photodegradation process of carminic acid, a natural red colourant used in beverages. For this purpose, both carminic acid aqueous standard solutions and sixteen different commercial beverages, ten containing carminic acid and six containing E120 dye, were subjected to photoirradiation. The results show different patterns of degradation, not only between the standard solutions and the beverages, but also from beverage to beverage. Due to the different beverage recipes, unpredictable reactions take place between the dye and the other ingredients. To identify the dye degradation products in a very complex scenario, a methodology was used, based on the combined use of principal component analysis with discriminant analysis and ultra-high-performance liquid chromatography coupled with tandem high resolution mass spectrometry. The methodology is unaffected by beverage composition and allows the degradation products of carminic acid dye to be identified for each beverage. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. FPGA based high-performance multi-channel analyzer with local histogram memory

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Vaidya, P.P.; Paulson, M.

    2004-01-01

    Modern nuclear spectroscopy systems demand for a Multi-Channel Analyzer (MCA) with higher resolution, faster speed and other advanced features. The MCA described here is targeted for such demanding applications. The MCA has an in-built local histogram memory and a memory management unit integrated in an FPGA (Field Programmable Gate Array) chip. In addition to the integrated low power digital circuitry, the system utilizes state of the art advanced analog circuits like low power, high speed and high precision comparators, op-amps, ADC and DAC. The operating resolution is selectable from 256 channels to 16384 channels for pulse height analysis. It supports high count rate applications (typically 100 KHz) without significant dead time penalty. It can have an USB bus interface with simple changes. In general, the MCA gives a high performance, compact and low power alternative for portable and battery operated systems as well as for high end laboratory instruments. (author)

  9. Performance Analysis of Ivshmem for High-Performance Computing in Virtual Machines

    Science.gov (United States)

    Ivanovic, Pavle; Richter, Harald

    2018-01-01

    High-Performance computing (HPC) is rarely accomplished via virtual machines (VMs). In this paper, we present a remake of ivshmem which can change this. Ivshmem was a shared memory (SHM) between virtual machines on the same server, with SHM-access synchronization included, until about 5 years ago when newer versions of Linux and its virtualization library libvirt evolved. We restored that SHM-access synchronization feature because it is indispensable for HPC and made ivshmem runnable with contemporary versions of Linux, libvirt, KVM, QEMU and especially MPICH, which is an implementation of MPI - the standard HPC communication library. Additionally, MPICH was transparently modified by us to get ivshmem included, resulting in a three to ten times performance improvement compared to TCP/IP. Furthermore, we have transparently replaced MPI_PUT, a single-side MPICH communication mechanism, by an own MPI_PUT wrapper. As a result, our ivshmem even surpasses non-virtualized SHM data transfers for block lengths greater than 512 KBytes, showing the benefits of virtualization. All improvements were possible without using SR-IOV.

  10. Fuel performance analysis code 'FAIR'

    International Nuclear Information System (INIS)

    Swami Prasad, P.; Dutta, B.K.; Kushwaha, H.S.; Mahajan, S.C.; Kakodkar, A.

    1994-01-01

    For modelling nuclear reactor fuel rod behaviour of water cooled reactors under severe power maneuvering and high burnups, a mechanistic fuel performance analysis code FAIR has been developed. The code incorporates finite element based thermomechanical module, physically based fission gas release module and relevant models for modelling fuel related phenomena, such as, pellet cracking, densification and swelling, radial flux redistribution across the pellet due to the build up of plutonium near the pellet surface, pellet clad mechanical interaction/stress corrosion cracking (PCMI/SSC) failure of sheath etc. The code follows the established principles of fuel rod analysis programmes, such as coupling of thermal and mechanical solutions along with the fission gas release calculations, analysing different axial segments of fuel rod simultaneously, providing means for performing local analysis such as clad ridging analysis etc. The modular nature of the code offers flexibility in affecting modifications easily to the code for modelling MOX fuels and thorium based fuels. For performing analysis of fuel rods subjected to very long power histories within a reasonable amount of time, the code has been parallelised and is commissioned on the ANUPAM parallel processing system developed at Bhabha Atomic Research Centre (BARC). (author). 37 refs

  11. [High-performance liquid-liquid chromatography in beverage analysis].

    Science.gov (United States)

    Bricout, J; Koziet, Y; de Carpentrie, B

    1978-01-01

    Liquid liquid chromatography was performed with columns packed with stationary phases chemically bonded to silica microparticules. These columns show a high efficiency and are used very easily. Flavouring compounds like aromatic aldehydes which have a low volatility were analyzed in brandy using a polar phase alkylnitrile. Sapid substances like amarogentin in Gentiana lutea or glyryrrhizin in Glycyrrhiza glabra were determined by reversed phase chromatography. Finally ionizable substances like synthetic dyes can be analyzed by paired ion chromatography witha non polar stationary phase.

  12. A multi-region assessment of population rates of cardiac catheterization and yield of high-risk coronary artery disease

    Directory of Open Access Journals (Sweden)

    Clement Fiona M

    2011-11-01

    Full Text Available Abstract Background There is variation in cardiac catheterization utilization across jurisdictions. Previous work from Alberta, Canada, showed no evidence of a plateau in the yield of high-risk disease at cardiac catheterization rates as high as 600 per 100,000 population suggesting that the optimal rate is higher. This work aims 1 To determine if a previously demonstrated linear relationship between the yield of high-risk coronary disease and cardiac catheterization rates persists with contemporary data and 2 to explore whether the linear relationship exists in other jurisdictions. Methods Detailed clinical information on all patients undergoing cardiac catheterization in 3 Canadian provinces was available through the Alberta Provincial Project for Outcomes Assessment in Coronary Heart (APPROACH disease and partner initiatives in British Columbia and Nova Scotia. Population rates of catheterization and high-risk coronary disease detection for each health region in these three provinces, and age-adjusted rates produced using direct standardization. A mixed effects regression analysis was performed to assess the relationship between catheterization rate and high-risk coronary disease detection. Results In the contemporary Alberta data, we found a linear relationship between the population catheterization rate and the high-risk yield. Although the yield was slightly less in time period 2 (2002-2006 than in time period 1(1995-2001, there was no statistical evidence of a plateau. The linear relationship between catheterization rate and high-risk yield was similarly demonstrated in British Columbia and Nova Scotia and appears to extend, without a plateau in yield, to rates over 800 procedures per 100,000 population. Conclusions Our study demonstrates a consistent finding, over time and across jurisdictions, of linearly increasing detection of high-risk CAD as population rates of cardiac catheterization increase. This internationally-relevant finding

  13. High rate amplifier-digitizer system for liquid argon calorimeters

    International Nuclear Information System (INIS)

    Droege, T.F.; Lobkowicz, F.; Fukushima, Y.

    1978-01-01

    A low-cost charge amplifier for a liquid argon photon detector and a new method for pulse height analysis are described. This scheme is suitable for high-energy photon detection with high counting rate. Samples of preamplifer output are taken just before and just after the arrival of the charge from the detector. The difference of these samples provides a stable pedestal and rejects low frequency noise. Short two-pulse resolving time (approximately equal to 200ns) is achieved. 6 refs

  14. EXTRACTION AND QUANTITATIVE ANALYSIS OF ELEMENTAL SULFUR FROM SULFIDE MINERAL SURFACES BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY. (R826189)

    Science.gov (United States)

    A simple method for the quantitative determination of elemental sulfur on oxidized sulfide minerals is described. Extraction of elemental sulfur in perchloroethylene and subsequent analysis with high-performance liquid chromatography were used to ascertain the total elemental ...

  15. Symbol and Bit Error Rates Analysis of Hybrid PIM-CDMA

    Directory of Open Access Journals (Sweden)

    Ghassemlooy Z

    2005-01-01

    Full Text Available A hybrid pulse interval modulation code-division multiple-access (hPIM-CDMA scheme employing the strict optical orthogonal code (SOCC with unity and auto- and cross-correlation constraints for indoor optical wireless communications is proposed. In this paper, we analyse the symbol error rate (SER and bit error rate (BER of hPIM-CDMA. In the analysis, we consider multiple access interference (MAI, self-interference, and the hybrid nature of the hPIM-CDMA signal detection, which is based on the matched filter (MF. It is shown that the BER/SER performance can only be evaluated if the bit resolution conforms to the condition set by the number of consecutive false alarm pulses that might occur and be detected, so that one symbol being divided into two is unlikely to occur. Otherwise, the probability of SER and BER becomes extremely high and indeterminable. We show that for a large number of users, the BER improves when increasing the code weight . The results presented are compared with other modulation schemes.

  16. Experimental characterization and modelling of UO2 mechanical behaviour at high temperatures and high strain rates

    International Nuclear Information System (INIS)

    Salvo, Maxime

    2014-01-01

    The aim of this work is to characterize and model the mechanical behavior of uranium dioxide (UO 2 ) during a Reactivity Initiated Accident (RIA). The fuel loading during a RIA is characterized by high strain rates (up to 1/s) and high temperatures (1000 C - 2500 C). Two types of UO 2 pellets (commercial and high density) were therefore tested in compression with prescribed displacement rates (0.1 to 100 mm/min corresponding to strain rates of 10 -4 - 10 -1 /s) and temperatures (1100 C - 1350 C - 1550 C et 1700 C). Experimental results (geometry, yield stress and microstructure) allowed us to define a hyperbolic sine creep law and a Drucker-Prager criterion with associated plasticity, in order to model grain boundaries fragmentation at the macroscopic scale. Finite Element Simulations of these tests and of more than 200 creep tests were used to assess the model response to a wide range of temperatures (1100 C - 1700 C) and strain rates (10 -9 /s - 10 -1 /s). Finally, a constitutive law called L3F was developed for UO 2 by adding to the previous model irradiation creep and tensile macroscopic cracking. The L3F law was then introduced in the 1.5D scheme of the fuel performance code ALCYONE-RIA to simulate the REP-Na tests performed in the experimental reactor CABRI. Simulation results are in good agreement with post tests examinations. (author) [fr

  17. Social motivation in prospective memory: higher importance ratings and reported performance rates for social tasks.

    Science.gov (United States)

    Penningroth, Suzanna L; Scott, Walter D; Freuen, Margaret

    2011-03-01

    Few studies have addressed social motivation in prospective memory (PM). In a pilot study and two main studies, we examined whether social PM tasks possess a motivational advantage over nonsocial PM tasks. In the pilot study and Study 1, participants listed their real-life important and less important PM tasks. Independent raters categorized the PM tasks as social or nonsocial. Results from both studies showed a higher proportion of tasks rated as social when important tasks were requested than when less important tasks were requested. In Study 1, participants also reported whether they had remembered to perform each PM task. Reported performance rates were higher for tasks rated as social than for those rated as nonsocial. Finally, in Study 2, participants rated the importance of two hypothetical PM tasks, one social and one nonsocial. The social PM task was rated higher in importance. Overall, these findings suggest that social PM tasks are viewed as more important than nonsocial PM tasks and they are more likely to be performed. We propose that consideration of the social relevance of PM will lead to a more complete and ecologically valid theoretical description of PM performance. (PsycINFO Database Record (c) 2011 APA, all rights reserved).

  18. RECENT ADVANCES IN ULTRA-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY FOR THE ANALYSIS OF TRADITIONAL CHINESE MEDICINE

    Science.gov (United States)

    Huang, Huilian; Liu, Min; Chen, Pei

    2014-01-01

    Traditional Chinese medicine has been widely used for the prevention and treatment of various diseases for thousands of years in China. Ultra-high performance liquid chromatography (UHPLC) is a relatively new technique offering new possibilities. This paper reviews recent developments in UHPLC in the separation and identification, fingerprinting, quantification, and metabolism of traditional Chinese medicine. Recently, the combination of UHPLC with MS has improved the efficiency of the analysis of these materials. PMID:25045170

  19. The Rate of Seasonal Changes in Temperature Alters Acclimation of Performance under Climate Change.

    Science.gov (United States)

    Nilsson-Örtman, Viktor; Johansson, Frank

    2017-12-01

    How the ability to acclimate will impact individual performance and ecological interactions under climate change remains poorly understood. Theory predicts that the benefit an organism can gain from acclimating depends on the rate at which temperatures change relative to the time it takes to induce beneficial acclimation. Here, we present a conceptual model showing how slower seasonal changes under climate change can alter species' relative performance when they differ in acclimation rate and magnitude. To test predictions from theory, we performed a microcosm experiment where we reared a mid- and a high-latitude damselfly species alone or together under the rapid seasonality currently experienced at 62°N and the slower seasonality predicted for this latitude under climate change and measured larval growth and survival. To separate acclimation effects from fixed thermal responses, we simulated growth trajectories based on species' growth rates at constant temperatures and quantified how much and how fast species needed to acclimate to match the observed growth trajectories. Consistent with our predictions, the results showed that the midlatitude species had a greater capacity for acclimation than the high-latitude species. Furthermore, since acclimation occurred at a slower rate than seasonal temperature changes, the midlatitude species had a small growth advantage over the high-latitude species under the current seasonality but a greater growth advantage under the slower seasonality predicted for this latitude under climate change. In addition, the two species did not differ in survival under the current seasonality, but the midlatitude species had higher survival under the predicted climate change scenario, possibly because rates of cannibalism were lower when smaller heterospecifics were present. These findings highlight the need to incorporate acclimation rates in ecological models.

  20. Local Electric Field Facilitates High-Performance Li-Ion Batteries.

    Science.gov (United States)

    Liu, Youwen; Zhou, Tengfei; Zheng, Yang; He, Zhihai; Xiao, Chong; Pang, Wei Kong; Tong, Wei; Zou, Youming; Pan, Bicai; Guo, Zaiping; Xie, Yi

    2017-08-22

    By scrutinizing the energy storage process in Li-ion batteries, tuning Li-ion migration behavior by atomic level tailoring will unlock great potential for pursuing higher electrochemical performance. Vacancy, which can effectively modulate the electrical ordering on the nanoscale, even in tiny concentrations, will provide tempting opportunities for manipulating Li-ion migratory behavior. Herein, taking CuGeO 3 as a model, oxygen vacancies obtained by reducing the thickness dimension down to the atomic scale are introduced in this work. As the Li-ion storage progresses, the imbalanced charge distribution emerging around the oxygen vacancies could induce a local built-in electric field, which will accelerate the ions' migration rate by Coulomb forces and thus have benefits for high-rate performance. Furthermore, the thus-obtained CuGeO 3 ultrathin nanosheets (CGOUNs)/graphene van der Waals heterojunctions are used as anodes in Li-ion batteries, which deliver a reversible specific capacity of 1295 mAh g -1 at 100 mA g -1 , with improved rate capability and cycling performance compared to their bulk counterpart. Our findings build a clear connection between the atomic/defect/electronic structure and intrinsic properties for designing high-efficiency electrode materials.

  1. Microspherical polyaniline/graphene nanocomposites for high performance supercapacitors

    Science.gov (United States)

    Cao, Hailiang; Zhou, Xufeng; Zhang, Yiming; Chen, Liang; Liu, Zhaoping

    2013-12-01

    Polyaniline/graphene nanocomposites with microspherical morphology and porous structure are prepared as electrode materials for supercapacitors. Using few-layer graphene obtained by liquid phase exfoliation of graphite as the raw material, porous graphene microspheres are produced by spray drying, and are then employed as the substrates for the growth of polyaniline nanowire arrays by in situ polymerization. In the composite, interconnected graphene sheets with few structural defects constitute a high-efficient conductive network to improve the electrical conductivity of polyaniline. Furthermore, the microspherical architecture prevents restacking of polyaniline/graphene composite nanosheets, thus facilitates fast diffusion of electrolytes. Consequently, the nanocomposite exhibits excellent electrochemical performance. A specific capacitance of 338 F g-1 is reached in 1 M H2SO4 at a scan rate of 20 mV s-1, and a high capacity retention rate of 87.4% after 10,000 cycles at a current density of 3 A g-1 can be achieved, which suggests that the polyaniline/graphene composite with such kind of 3D architecture is a promising electrode material for high-performance supercapacitors.

  2. Spacecraft Multiple Array Communication System Performance Analysis

    Science.gov (United States)

    Hwu, Shian U.; Desilva, Kanishka; Sham, Catherine C.

    2010-01-01

    The Communication Systems Simulation Laboratory (CSSL) at the NASA Johnson Space Center is tasked to perform spacecraft and ground network communication system simulations, design validation, and performance verification. The CSSL has developed simulation tools that model spacecraft communication systems and the space and ground environment in which the tools operate. In this paper, a spacecraft communication system with multiple arrays is simulated. Multiple array combined technique is used to increase the radio frequency coverage and data rate performance. The technique is to achieve phase coherence among the phased arrays to combine the signals at the targeting receiver constructively. There are many technical challenges in spacecraft integration with a high transmit power communication system. The array combining technique can improve the communication system data rate and coverage performances without increasing the system transmit power requirements. Example simulation results indicate significant performance improvement can be achieved with phase coherence implementation.

  3. The Fuel Performance Analysis of LWR Fuel containing High Thermal Conductivity Reinforcements

    International Nuclear Information System (INIS)

    Kim, Seung Su; Ryu, Ho Jin

    2015-01-01

    The thermal conductivity of fuel affects many performance parameters including the fuel centerline temperature, fission gas release and internal pressure. In addition, enhanced safety margin of fuel might be expected when the thermal conductivity of fuel is improved by the addition of high thermal conductivity reinforcements. Therefore, the effects of thermal conductivity enhancement on the fuel performance of reinforced UO2 fuel with high thermal conductivity compounds should be analyzed. In this study, we analyzed the fuel performance of modified UO2 fuel with high thermal conductivity reinforcements by using the FRAPCON-3.5 code. The fissile density and mechanical properties of the modified fuel are considered the same with the standard UO2 fuel. The fuel performance of modified UO2 with high thermal conductivity reinforcements were analyzed by using the FRAPCON-3.5 code. The thermal conductivity enhancement factors of the modified fuels were obtained from the Maxwell model considering the volume fraction of reinforcements

  4. Precision tracking at high background rates with the ATLAS muon spectrometer

    CERN Document Server

    Hertenberger, Ralf; The ATLAS collaboration

    2012-01-01

    Since start of data taking the ATLAS muon spectrometer performs according to specification. End of this decade after the luminosity upgrade of LHC by a factor of ten the proportionally increasing background rates require the replacement of the detectors in the most forward part of the muon spectrometer to ensure high quality muon triggering and tracking at background hit rates of up to 15,kHz/cm$^2$. Square meter sized micromegas detectors together with improved thin gap trigger detectors are suggested as replacement. Micromegas detectors are intrinsically high rate capable. A single hit spatial resolution below 40,$mu$m has been shown for 250,$mu$m anode strip pitch and perpendicular incidence of high energy muons or pions. The ongoing development of large micromegas structures and their investigation under non-perpendicular incidence or in high background environments requires precise and reliable monitoring of muon tracks. A muon telescope consisting of six small micromegas works reliably and is presently ...

  5. Componential Analysis of Analogical-Reasoning Performance of High and Low Achievers.

    Science.gov (United States)

    Armour-Thomas, Eleanor; Allen, Brenda A.

    1990-01-01

    Assessed analogical reasoning in high- and low-achieving students at the high school level and determined whether analogical reasoning was related to academic achievement in ninth grade students (N=54). Results indicated that high achievers performed better than low achievers on all types of analogical-reasoning processes. (Author/ABL)

  6. Online physician ratings fail to predict actual performance on measures of quality, value, and peer review.

    Science.gov (United States)

    Daskivich, Timothy J; Houman, Justin; Fuller, Garth; Black, Jeanne T; Kim, Hyung L; Spiegel, Brennan

    2018-04-01

    Patients use online consumer ratings to identify high-performing physicians, but it is unclear if ratings are valid measures of clinical performance. We sought to determine whether online ratings of specialist physicians from 5 platforms predict quality of care, value of care, and peer-assessed physician performance. We conducted an observational study of 78 physicians representing 8 medical and surgical specialties. We assessed the association of consumer ratings with specialty-specific performance scores (metrics including adherence to Choosing Wisely measures, 30-day readmissions, length of stay, and adjusted cost of care), primary care physician peer-review scores, and administrator peer-review scores. Across ratings platforms, multivariable models showed no significant association between mean consumer ratings and specialty-specific performance scores (β-coefficient range, -0.04, 0.04), primary care physician scores (β-coefficient range, -0.01, 0.3), and administrator scores (β-coefficient range, -0.2, 0.1). There was no association between ratings and score subdomains addressing quality or value-based care. Among physicians in the lowest quartile of specialty-specific performance scores, only 5%-32% had consumer ratings in the lowest quartile across platforms. Ratings were consistent across platforms; a physician's score on one platform significantly predicted his/her score on another in 5 of 10 comparisons. Online ratings of specialist physicians do not predict objective measures of quality of care or peer assessment of clinical performance. Scores are consistent across platforms, suggesting that they jointly measure a latent construct that is unrelated to performance. Online consumer ratings should not be used in isolation to select physicians, given their poor association with clinical performance.

  7. A Prediction Model for Community Colleges Using Graduation Rate as the Performance Indicator

    Science.gov (United States)

    Moosai, Susan

    2010-01-01

    In this thesis a prediction model using graduation rate as the performance indicator is obtained for community colleges for three cohort years, 2003, 2004, and 2005 in the states of California, Florida, and Michigan. Multiple Regression analysis, using an aggregate of seven predictor variables, was employed in determining this prediction model.…

  8. Delayed high school start times later than 8:30am and impact on graduation rates and attendance rates.

    Science.gov (United States)

    McKeever, Pamela Malaspina; Clark, Linda

    2017-04-01

    The first purpose of this study was to investigate changes in high school graduation rates with a delayed school start time of later than 8:30am. The second aim of the study was to analyze the association between a delayed high school start time later than 8:30am and attendance rates. In the current study, a pre-post design using a repeated-measures analysis of variance was used to examine changes in attendance and graduation rates 2 years after a delayed start was implemented. Public high schools from 8 school districts (n=29 high schools) located throughout 7 different states. Schools were identified using previous research from the Children's National Medical Center's Division of Sleep Medicine Research Team. A total membership of more than 30,000 high school students enrolled in the 29 schools identified by the Children's National Medical Center's Research Team. A pre-post design was used for a within-subject design, controlling for any school-to-school difference in the calculation of the response variable. This is the recommended technique for a study that may include data with potential measurement error. Findings from this study linked a start time of later than 8:30am to improved attendance rates and graduation rates. Attendance rates and graduation rates significantly improved in schools with delayed start times of 8:30am or later. School officials need to take special notice that this investigation also raises questions about whether later start times are a mechanism for closing the achievement gap due to improved graduation rates. Copyright © 2017 National Sleep Foundation. Published by Elsevier Inc. All rights reserved.

  9. Validity analysis on merged and averaged data using within and between analysis: focus on effect of qualitative social capital on self-rated health.

    Science.gov (United States)

    Shin, Sang Soo; Shin, Young-Jeon

    2016-01-01

    With an increasing number of studies highlighting regional social capital (SC) as a determinant of health, many studies are using multi-level analysis with merged and averaged scores of community residents' survey responses calculated from community SC data. Sufficient examination is required to validate if the merged and averaged data can represent the community. Therefore, this study analyzes the validity of the selected indicators and their applicability in multi-level analysis. Within and between analysis (WABA) was performed after creating community variables using merged and averaged data of community residents' responses from the 2013 Community Health Survey in Korea, using subjective self-rated health assessment as a dependent variable. Further analysis was performed following the model suggested by WABA result. Both E-test results (1) and WABA results (2) revealed that single-level analysis needs to be performed using qualitative SC variable with cluster mean centering. Through single-level multivariate regression analysis, qualitative SC with cluster mean centering showed positive effect on self-rated health (0.054, panalysis using SC variables without cluster mean centering or multi-level analysis. As modification in qualitative SC was larger within the community than between communities, we validate that relational analysis of individual self-rated health can be performed within the group, using cluster mean centering. Other tests besides the WABA can be performed in the future to confirm the validity of using community variables and their applicability in multi-level analysis.

  10. Development of high-throughput analysis system using highly-functional organic polymer monoliths

    International Nuclear Information System (INIS)

    Umemura, Tomonari; Kojima, Norihisa; Ueki, Yuji

    2008-01-01

    The growing demand for high-throughput analysis in the current competitive life sciences and industries has promoted the development of high-speed HPLC techniques and tools. As one of such tools, monolithic columns have attracted increasing attention and interest in the last decade due to the low flow-resistance and excellent mass transfer, allowing for rapid separations and reactions at high flow rates with minimal loss of column efficiency. Monolithic materials are classified into two main groups: silica- and organic polymer-based monoliths, each with their own advantages and disadvantages. Organic polymer monoliths have several distinct advantages in life-science research, including wide pH stability, less irreversible adsorption, facile preparation and modification. Thus, we have so far tried to develop organic polymer monoliths for various chemical operations, such as separation, extraction, preconcentration, and reaction. In the present paper, recent progress in the development of organic polymer monoliths is discussed. Especially, the procedure for the preparation of methacrylate-based monoliths with various functional groups is described, where the influence of different compositional and processing parameters on the monolithic structure is also addressed. Furthermore, the performance of the produced monoliths is demonstrated through the results for (1) rapid separations of alklybenzenes at high flow rates, (2) flow-through enzymatic digestion of cytochrome c on a trypsin-immobilized monolithic column, and (3) separation of the tryptic digest on a reversed-phase monolithic column. The flexibility and versatility of organic polymer monoliths will be beneficial for further enhancing analytical performance, and will open the way for new applications and opportunities both in scientific and industrial research. (author)

  11. Crash rates analysis in China using a spatial panel model

    Directory of Open Access Journals (Sweden)

    Wonmongo Lacina Soro

    2017-10-01

    Full Text Available The consideration of spatial externalities in traffic safety analysis is of paramount importance for the success of road safety policies. Yet, the quasi-totality of spatial dependence studies on crash rates is performed within the framework of single-equation spatial cross-sectional studies. The present study extends the spatial cross-sectional scheme to a spatial fixed-effects panel model estimated using the maximum likelihood method. The spatial units are the 31 administrative regions of mainland China over the period 2004–2013. The presence of neighborhood effects is evidenced through the Moran's I statistic. Consistent with previous studies, the analysis reveals that omitting the spatial effects in traffic safety analysis is likely to bias the estimation results. The spatial and error lags are all positive and statistically significant suggesting similarities of crash rates pattern in neighboring regions. Some other explanatory variables, such as freight traffic, the length of paved roads and the populations of age 65 and above are related to higher rates while the opposite trend is observed for the Gross Regional Product, the urban unemployment rate and passenger traffic.

  12. High rate multiplicity detector for relativistic heavy-ion collisions

    International Nuclear Information System (INIS)

    Beavis, D.; Bennett, M.J.; Carroll, J.B.; Chiba, J.; Chikanian, A.; Crawford, H.J.; Cronqvist, M.; Dardenne, Y.; Debbe, R.; Doke, T.; Engelage, J.; Flores, I.; Greiner, L.; Hayano, R.S.; Hallman, T.J.; Heckman, H.H.; Kashiwagi, T.; Kikuchi, J.; Kumar, B.S.; Kuo, C.; Lindstrom, P.J.; Mitchell, J.W.; Nagamiya, S.; Nagle, J.L.; Pope, J.K.; Stankus, P.; Tanaka, K.H.; Welsh, R.C.; Zhan, W.

    1995-01-01

    We have constructed and operated a detector to measure the multiplicity of secondary particles produced in nucleus-nucleus collisions in the E878 experiment at the Brookhaven National Laboratory AGS facility. We describe the operation and performance of the detector in a high rate Au beam environment, and interpret the multiplicity data in terms of the impact parameters of the nucleus-nucleus collisions. ((orig.))

  13. High rate multiplicity detector for relativistic heavy-ion collisions

    Energy Technology Data Exchange (ETDEWEB)

    Beavis, D [Brookhaven National Lab., Upton, NY (United States); Bennett, M J [Yale University, A.W. Wright Nuclear Structure Laboratory, New Haven, CT 06511 (United States); Carroll, J B [University of California at Los Angeles, Los Angeles, CA (United States); Chiba, J [KEK National High Energy Physics, Tsukuba (Japan); Chikanian, A [Yale University, A.W. Wright Nuclear Structure Laboratory, New Haven, CT 06511 (United States); Crawford, H J [University of California Space Sciences Laboratory, Berkeley, CA (United States); Cronqvist, M [University of California Space Sciences Laboratory, Berkeley, CA (United States); Dardenne, Y [University of California Space Sciences Laboratory, Berkeley, CA (United States); Debbe, R [Brookhaven National Lab., Upton, NY (United States); Doke, T [Waseda University, Science and Engineering Research Institute, Waseda (Japan); Engelage, J [University of California Space Sciences Laboratory, Berkeley, CA (United States); Flores, I [University of California Space Sciences Laboratory, Berkeley, CA (United States); Greiner, L [University of California Space Sciences Laboratory, Berkeley, CA (United States); Hayano, R S [University of Tokyo, Tokyo (Japan); Hallman, T J [University of California at Los Angeles, Los Angeles, CA (United States); Heckman, H H [Lawrence Berkeley Lab., CA (United States); Kashiwagi, T [Waseda University, Science and Engineering Research Institute, Waseda (Japan); Kikuchi, J [Waseda University, Science and Engineering Research Institute, Waseda (Japan); Kumar, B S [Yale University, A.W. Wright Nuclear Structure Laboratory, New Haven, CT 06511 (United States); Kuo, C [University of California Space Sciences Laboratory, Berkeley, CA (United States); Lindstrom, P J [Lawrence Berkeley Lab., CA (United States); Mitchell, J W [Universities Space Research Association/Goddard Space Flight Center, Greenbelt, MD (United States); Nagamiya, S; E878 Collaboration

    1995-04-21

    We have constructed and operated a detector to measure the multiplicity of secondary particles produced in nucleus-nucleus collisions in the E878 experiment at the Brookhaven National Laboratory AGS facility. We describe the operation and performance of the detector in a high rate Au beam environment, and interpret the multiplicity data in terms of the impact parameters of the nucleus-nucleus collisions. ((orig.)).

  14. A parametric study of rate of advance and area coverage rate performance of synthetic aperture radar.

    Energy Technology Data Exchange (ETDEWEB)

    Raynal, Ann Marie [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Hensley, Jr., William H. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Burns, Bryan L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Doerry, Armin Walter [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2014-11-01

    The linear ground distance per unit time and ground area covered per unit time of producing synthetic aperture radar (SAR) imagery, termed rate of advance (ROA) and area coverage rate (ACR), are important metrics for platform and radar performance in surveillance applications. These metrics depend on many parameters of a SAR system such as wavelength, aircraft velocity, resolution, antenna beamwidth, imaging mode, and geometry. Often the effects of these parameters on rate of advance and area coverage rate are non-linear. This report addresses the impact of different parameter spaces as they relate to rate of advance and area coverage rate performance.

  15. A quantitative analysis of two-dimensional manually segmented transrectal ultrasound axial images in planning high dose rate brachytherapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Dabić-Stanković Kata

    2017-01-01

    Full Text Available Background/Aim. Prostate delineation, pre-planning and catheter implantation procedures, in high-dose rate brachytherapy (HDR-BT, are commonly based on the prostate manually segmented transrectal ultrasound (TRUS images. The aim of this study was to quantitatively analyze the consistency of prostate capsule delineation, done by a single therapist, prior to each HDR-BT fraction and the changes in the shape of the prostate capsule during HDR-BT, using two dimensional (2D TRUS axial image. Methods. A group of 16 patients were treated at the Medical System Belgrade Brachytherapy Department with definitive HDRBT. The total applied median dose of 52 Gy was divided into four individual fractions, each fraction being delivered 2– 3 weeks apart. Real time prostate axial visualization and the manual segmentation prior to each fraction were performed using B-K Medical ultrasound. Quantitative analyses, analysis of an area and shape were applied on 2D-TRUS axial images of the prostate. Area analyses were used to calculate the average value of the cross-sectional area of the prostate image. The parameters of the prostate shape, the fractal dimension and the circularity ratio of the prostate capsule contour were estimated at the maximum axial cross section of the prostate image. Results. The sample group consisted of four phases, each phase being performed prior to the first, second, third and fourth HDR-BT fraction, respectively. Statistical analysis showed that during HDR-BT fractions there were no significant differences in the average value of area, as well as in the maximum shape of prostate capsule. Conclusions. Quantitative analysis of TRUS axial prostate segmented images shows a successful capsule delineation in the series of manually segmented TRUS images, and the prostate maximum shape remaining unchanged during HDR-BT fractions.

  16. CFD analysis of heat transfer performance of graphene based hybrid nanofluid in radiators

    Science.gov (United States)

    Bharadwaj, Bharath R.; Sanketh Mogeraya, K.; Manjunath, D. M.; Rao Ponangi, Babu; Rajendra Prasad, K. S.; Krishna, V.

    2018-04-01

    For Improved performance of an automobile engine, Cooling systems are one of the critical systems that need attention. With increased capacity to carry away large amounts of wasted heat, performance of an engine is increased. Current research on Nano-fluids suggests that they offer higher heat transfer rate compared to that of conventional coolants. Hence this project seeks to investigate the use of hybrid-nanofluids in radiators so as to increase its heat transfer performance. Carboxyl Graphene and Graphene Oxide based nanoparticles were selected due to the very high thermal conductivity of Graphene. System Analysis of the radiator was performed by considering a small part of the whole automobile radiator modelled using SEIMENS NX. CFD analysis was conducted using ANSYS FLUENT® for the nanofluid defined and the increase in effectiveness was compared to that of conventional coolants. Usage of such nanofluids for a fixed cooling requirement in the future can lead to significant downsizing of the radiator.

  17. Development of high performance cladding materials

    International Nuclear Information System (INIS)

    Park, Jeong Yong; Jeong, Y. H.; Park, S. Y.

    2010-04-01

    The irradiation test for HANA claddings conducted and a series of evaluation for next-HANA claddings as well as their in-pile and out-of pile performances tests were also carried out at Halden research reactor. The 6th irradiation test have been completed successfully in Halden research reactor. As a result, HANA claddings showed high performance, such as corrosion resistance increased by 40% compared to Zircaloy-4. The high performance of HANA claddings in Halden test has enabled lead test rod program as the first step of the commercialization of HANA claddings. DB has been established for thermal and LOCA-related properties. It was confirmed from the thermal shock test that the integrity of HANA claddings was maintained in more expanded region than the criteria regulated by NRC. The manufacturing process of strips was established in order to apply HANA alloys, which were originally developed for the claddings, to the spacer grids. 250 kinds of model alloys for the next-generation claddings were designed and manufactured over 4 times and used to select the preliminary candidate alloys for the next-generation claddings. The selected candidate alloys showed 50% better corrosion resistance and 20% improved high temperature oxidation resistance compared to the foreign advanced claddings. We established the manufacturing condition controlling the performance of the dual-cooled claddings by changing the reduction rate in the cold working steps

  18. real exchange rate misalignment and economic performance in ...

    African Journals Online (AJOL)

    ... effects of real exchange rate misalignment on economic performance in Nigeria. .... main factors that impacts on real exchange rate in India .... financial assets and ignores non-economic factor such as .... and fiscal policies to control inflation.

  19. Analysis of metalaxyl racemate using high performance liquid chromatography coupled with four kinds of detectors.

    Science.gov (United States)

    Chen, Tao; Fan, Jun; Gao, Ruiqi; Wang, Tai; Yu, Ying; Zhang, Weiguang

    2016-10-07

    Chiral stationary phase-high performance liquid chromatography coupled with various detectors has been one of most commonly used methods for analysis and separation of chiral compounds over the past decades. Various detectors exhibit different characteristics in qualitative and quantitative studies under different chromatographic conditions. Herein, a comparative evaluation of HPLC coupled with ultraviolet, optical rotation, refractive index, and evaporative light scattering detectors has been conducted for qualitative and quantitative analyses of metalaxyl racemate. Effects of separation conditions on the peak area ratio between two enantiomers, including sample concentration, column temperature, mobile phase composition, as well as flow rate, have been investigated in detail. In addition, the limits of detection, the limits of quantitation, quantitative range and precision for these two enantiomers by using four detectors have been also studied. As indicated, the chromatographic separation conditions have been slight effects on ultraviolet and refractive index detections and the peak area ratio between two enantiomers remains almost unchanged, but the evaporative light scattering detection has been significantly affected by the above-mentioned chromatographic conditions and the corresponding peak area ratios varied greatly. Moreover, the limits of detection, the limits of quantitation, and the quantitative ranges of two enantiomers with UV detection were remarkably lower by 1-2 magnitudes than the others. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Conductor and Ensemble Performance Expressivity and State Festival Ratings

    Science.gov (United States)

    Price, Harry E.; Chang, E. Christina

    2005-01-01

    This study is the second in a series examining the relationship between conducting and ensemble performance. The purpose was to further examine the associations among conductor, ensemble performance expressivity, and festival ratings. Participants were asked to rate the expressivity of video-only conducting and parallel audio-only excerpts from a…

  1. High-performance liquid chromatography with fluorescence detection for the rapid analysis of pheophytins and pyropheophytins in virgin olive oil.

    Science.gov (United States)

    Li, Xueqi; Woodman, Michael; Wang, Selina C

    2015-08-01

    Pheophytins and pyropheophytin are degradation products of chlorophyll pigments, and their ratios can be used as a sensitive indicator of stress during the manufacturing and storage of olive oil. They increase over time depending on the storage condition and if the oil is exposed to heat treatments during the refining process. The traditional analysis method includes solvent- and time-consuming steps of solid-phase extraction followed by analysis by high-performance liquid chromatography with ultraviolet detection. We developed an improved dilute/fluorescence method where multi-step sample preparation was replaced by a simple isopropanol dilution before the high-performance liquid chromatography injection. A quaternary solvent gradient method was used to include a fourth strong solvent wash on a quaternary gradient pump, which avoided the need to premix any solvents and greatly reduced the oil residues on the column from previous analysis. This new method not only reduces analysis cost and time but shows reliability, repeatability, and improved sensitivity, especially important for low-level samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Power spectral analysis of heart rate in hyperthyroidism.

    Science.gov (United States)

    Cacciatori, V; Bellavere, F; Pezzarossa, A; Dellera, A; Gemma, M L; Thomaseth, K; Castello, R; Moghetti, P; Muggeo, M

    1996-08-01

    The aim of the present study was to evaluate the impact of hyperthyroidism on the cardiovascular system by separately analyzing the sympathetic and parasympathetic influences on heart rate. Heart rate variability was evaluated by autoregressive power spectral analysis. This method allows a reliable quantification of the low frequency (LF) and high frequency (HF) components of the heart rate power spectral density; these are considered to be under mainly sympathetic and pure parasympathetic control, respectively. In 10 newly diagnosed untreated hyperthyroid patients with Graves' disease, we analyzed power spectral density of heart rate cyclic variations at rest, while lying, and while standing. In addition, heart rate variations during deep breathing, lying and standing, and Valsalva's maneuver were analyzed. The results were compared to those obtained from 10 age-, sex-, and body mass index-matched control subjects. In 8 hyperthyroid patients, the same evaluation was repeated after the induction of stable euthyroidism by methimazole. Heart rate power spectral analysis showed a sharp reduction of HF components in hyperthyroid subjects compared to controls [lying, 13.3 +/- 4.1 vs. 32.0 +/- 5.6 normalized units (NU; P hyperthyroid subjects while both lying (11.3 +/- 4.5 vs. 3.5 +/- 1.1; P hyperthyroid patients than in controls (1.12 +/- 0.03 vs. 1.31 +/- 0.04; P activity and, thus, a relative hypersympathetic tone.

  3. Co-modification of nitrogen-doped graphene and carbon on Li3V2(PO4)3 particles with excellent long-term and high-rate performance for lithium storage

    Science.gov (United States)

    Ren, Manman; Yang, Mingzhi; Liu, Weiliang; Li, Mei; Su, Liwei; Wu, Xianbin; Wang, Yuanhao

    2016-09-01

    In this work, N-doped graphene and carbon co-modified Li3V2(PO4)3 composites (LVP/NGC) are successfully fabricated through a xerogel method for the first time. The obtained architecture combines two types of electronic contact with Li3V2(PO4)3 particles: the point-to-face contact of N-doped graphene and the face-to-face contact of N-doped carbon coating layers. Profiting from the favorable complex structure, graphene and carbon coating layers offer an extraordinary network for electron transfer and hence an excellent long-term and high-rate performance. Even tested at the rate of 40 C, the reversible capacity still maintains 86.9 mAh g-1 after 800 cycles without any fading. This work provides a promising route to improve the long-term and high-rate performance of cathodes for LIBs and enlightens us on exploring preferable strategies to develop advanced electrode materials for other energy storage devices.

  4. High dose rate brachytherapy for the palliation of malignant dysphagia

    International Nuclear Information System (INIS)

    Homs, Marjolein Y.V.; Eijkenboom, Wilhelmina M.H.; Coen, Veronique L.M.A.; Haringsma, Jelle; Blankenstein, Mark van; Kuipers, Ernst J.; Siersema, Peter D.

    2003-01-01

    Background and purpose: High dose rate (HDR) brachytherapy is a commonly used palliative treatment for esophageal carcinoma. We evaluated the outcome of HDR brachytherapy in patients with malignant dysphagia. Material and methods: A retrospective analysis over a 10-year period was performed of 149 patients treated with HDR brachytherapy, administered in one or two sessions, at a median dose of 15 Gy. Patients were evaluated for functional outcome, complications, recurrent dysphagia, and survival. Results: At 6 weeks after HDR brachytherapy, dysphagia scores had improved from a median of 3 to 2 (n=104; P<0.001), however, dysphagia had not improved in 51 (49%) patients. Procedure-related complications occurred in seven (5%) patients. Late complications, including fistula formation or bleeding, occurred in 11 (7%) patients. Twelve (8%) patients experienced minor retrosternal pain. Median survival of the patients was 160 days with a 1-year survival rate of 15%. Procedure-related mortality was 2%. At follow-up, 55 (37%) patients experienced recurrent dysphagia. In 34 (23%) patients a metal stent was placed to relieve persistent or recurrent dysphagia. Conclusion: HDR brachytherapy is a moderately effective treatment for the palliation of malignant dysphagia. The incidence of early major complications is low, however, persistent and recurrent dysphagia occur frequently, and require often additional treatment

  5. State-level high school completion rates: Concepts, measures, and trends.

    Directory of Open Access Journals (Sweden)

    John Robert Warren

    2005-12-01

    Full Text Available Since the mid 1970s the national rate at which incoming 9th graders have completed high school has fallen slowly but steadily; this is also true in 41 states. In 2002, about three in every four students who might have completed high school actually did so; in some states this figure is substantially lower. In this paper I review state-level measures of high school completion rates and describe and validate a new measure that reports these rates for 1975 through 2002. Existing measures based on the Current Population Survey are conceptually imperfect and statistically unreliable. Measures based on Common Core Data (CCD dropout information are unavailable for many states and have different conceptual weaknesses. Existing measures based on CCD enrollment and completion data are systematically biased by migration, changes in cohort size, and/or grade retention. The new CCD-based measure described here is considerably less biased, performs differently in empirical analyses, and gives a different picture of the dropout situation across states and over time.

  6. Time-Efficient High-Rate Data Flooding in One-Dimensional Acoustic Underwater Sensor Networks

    Directory of Open Access Journals (Sweden)

    Jae Kyun Kwon

    2015-10-01

    Full Text Available Because underwater communication environments have poor characteristics, such as severe attenuation, large propagation delays and narrow bandwidths, data is normally transmitted at low rates through acoustic waves. On the other hand, as high traffic has recently been required in diverse areas, high rate transmission has become necessary. In this paper, transmission/reception timing schemes that maximize the time axis use efficiency to improve the resource efficiency for high rate transmission are proposed. The excellence of the proposed scheme is identified by examining the power distributions by node, rate bounds, power levels depending on the rates and number of nodes, and network split gains through mathematical analysis and numerical results. In addition, the simulation results show that the proposed scheme outperforms the existing packet train method.

  7. Results in patients treated with high-dose-rate interstitial brachytherapy for oral tongue cancer

    International Nuclear Information System (INIS)

    Yamamoto, Michinori; Shirane, Makoto; Ueda, Tsutomu; Miyahara, Nobuyuki

    2006-01-01

    Eight patients were treated with high-dose-rate interstitial brachytherapy for oral tongue cancer between September 2000 and August 2004. The patient distribution was 1 T1, 5 T2, 1 T3, and 1 T4a. Patients received 50-60 Gy in 10 fractions over seven days with high-dose-rate brachytherapy. Six of the eight patients were treated with a combination of external beam radiotherapy (20-30 Gy) and interstitial brachytherapy. The two-year primary local control rate was 83% for initial case. High-dose-rate brachytherapy was performed safely even for an aged person, and was a useful treatment modality for oral tongue cancer. (author)

  8. High-performance phase-field modeling

    KAUST Repository

    Vignal, Philippe; Sarmiento, Adel; Cortes, Adriano Mauricio; Dalcin, L.; Collier, N.; Calo, Victor M.

    2015-01-01

    and phase-field crystal equation will be presented, which corroborate the theoretical findings, and illustrate the robustness of the method. Results related to more challenging examples, namely the Navier-Stokes Cahn-Hilliard and a diusion-reaction Cahn-Hilliard system, will also be presented. The implementation was done in PetIGA and PetIGA-MF, high-performance Isogeometric Analysis frameworks [1, 3], designed to handle non-linear, time-dependent problems.

  9. Neutral monosaccharide composition analysis of plant-derived oligo- and polysaccharides by high performance liquid chromatography.

    Science.gov (United States)

    Yan, Jun; Shi, Songshan; Wang, Hongwei; Liu, Ruimin; Li, Ning; Chen, Yonglin; Wang, Shunchun

    2016-01-20

    A novel analytical method for neutral monosaccharide composition analysis of plant-derived oligo- and polysaccharides was developed using hydrophilic interaction liquid chromatography coupled to a charged aerosol detector. The effects of column type, additives, pH and column temperature on retention and separation were evaluated. Additionally, the method could distinguish potential impurities in samples, including chloride, sulfate and sodium, from sugars. The results of validation demonstrated that this method had good linearity (R(2) ≥ 0.9981), high precision (relative standard deviation ≤ 4.43%), and adequate accuracy (94.02-103.37% recovery) and sensitivity (detection limit: 15-40 ng). Finally, the monosaccharide compositions of the polysaccharide from Eclipta prostrasta L. and stachyose were successfully profiled through this method. This report represents the first time that all of these common monosaccharides could be well-separated and determined simultaneously by high performance liquid chromatography without additional derivatization. This newly developed method is convenient, efficient and reliable for monosaccharide analysis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Staff background paper on performance-based rate making

    International Nuclear Information System (INIS)

    Fraser, J.; Brownell, B.

    1998-10-01

    An alternative to the traditional cost of service (COS) regulation for electric utilities in British Columbia has been proposed. The alternative to pure COS regulation is performance-based rate making (PBR). PBR partially decouples a utility's rates from its costs and ties utility profits to performance relative to specific benchmarks. The motivation underlying PBR is that ideally, it provides incentives for utilities to cost-effectively achieve pre-defined goals. This report describes the design of PBR mechanisms, base rate PBR formulas, base rate PBR in other jurisdictions including New York, California, Maine and New Jersey. The report also describes gas procurement PBR in other jurisdictions, as well as British Columbia Utilities' Commission's own experience with PBR. In general, PBR has the potential to provide resource efficiency, allocative efficiency, support for introduction of new services, and reduced regulatory administrative costs. 15 refs., 4 tabs

  11. High Performance Proactive Digital Forensics

    International Nuclear Information System (INIS)

    Alharbi, Soltan; Traore, Issa; Moa, Belaid; Weber-Jahnke, Jens

    2012-01-01

    With the increase in the number of digital crimes and in their sophistication, High Performance Computing (HPC) is becoming a must in Digital Forensics (DF). According to the FBI annual report, the size of data processed during the 2010 fiscal year reached 3,086 TB (compared to 2,334 TB in 2009) and the number of agencies that requested Regional Computer Forensics Laboratory assistance increasing from 689 in 2009 to 722 in 2010. Since most investigation tools are both I/O and CPU bound, the next-generation DF tools are required to be distributed and offer HPC capabilities. The need for HPC is even more evident in investigating crimes on clouds or when proactive DF analysis and on-site investigation, requiring semi-real time processing, are performed. Although overcoming the performance challenge is a major goal in DF, as far as we know, there is almost no research on HPC-DF except for few papers. As such, in this work, we extend our work on the need of a proactive system and present a high performance automated proactive digital forensic system. The most expensive phase of the system, namely proactive analysis and detection, uses a parallel extension of the iterative z algorithm. It also implements new parallel information-based outlier detection algorithms to proactively and forensically handle suspicious activities. To analyse a large number of targets and events and continuously do so (to capture the dynamics of the system), we rely on a multi-resolution approach to explore the digital forensic space. Data set from the Honeynet Forensic Challenge in 2001 is used to evaluate the system from DF and HPC perspectives.

  12. System-theoretic analysis of due-time performance in production systems

    Directory of Open Access Journals (Sweden)

    David Jacobs

    1995-01-01

    Full Text Available Along with the average production rate, the due-time performance is an important characteristic of manufacturing systems. Unlike the production rate, the due-time performance has received relatively little attention in the literature, especially in the context of large volume production. This paper is devoted to this topic. Specifically, the notion of due-time performance is formalized as the probability that the number of parts produced during the shipping period reaches the required shipment size. This performance index is analyzed for both lean and mass manufacturing environments. In particular, it is shown that, to achieve a high due-time performance in a lean environment, the production system should be scheduled for a sufficiently small fraction of its average production rate. In mass production, due-time performance arbitrarily close to one can be achieved for any scheduling practice, up to the average production rate.

  13. Operation of high rate microstrip gas chambers

    CERN Document Server

    Barr, A J; Bouclier, Roger; Capéans-Garrido, M; Dominik, Wojciech; Manzin, G; Million, Gilbert; Hoch, M; Ropelewski, Leszek; Sauli, Fabio; Sharma, A

    1996-01-01

    We describe recent measurements carried out in well controlled and reproducible conditions to help understanding the factors affecting the short and long term behaviour of Microstrip Gas Chambers. Special care has been taken concerning the gas purity and choice of materials used in the system and for the detectors construction. Detectors built on glasses with surface resistivity in the range $10^{13}-10^{15} \\Omega/\\Box$ have shown satisfactory performance as they do not show charging-up process at high rate and stand the large doses required for the future high luminosity experiments (~10 mC·cm-1·yr-1). Concerning the lifetime measurements, it has been observed that chambers manufactured on high-resistivity glass are far more susceptible of suffering ageing than detectors made on low resistivity, electron-conducting supports, independently of the metal used for the artwork (chromium or gold) at least in clean gas conditions. The successfully operation in the laboratory of detectors manufactured on diamond-...

  14. Ultra-high performance, solid-state, autoradiographic image digitization and analysis system

    International Nuclear Information System (INIS)

    Lear, J.L.; Pratt, J.P.; Ackermann, R.F.; Plotnick, J.; Rumley, S.

    1990-01-01

    We developed a Macintosh II-based, charge-coupled device (CCD), image digitization and analysis system for high-speed, high-resolution quantification of autoradiographic image data. A linear CCD array with 3,500 elements was attached to a precision drive assembly and mounted behind a high-uniformity lens. The drive assembly was used to sweep the array perpendicularly to its axis so that an entire 20 x 25-cm autoradiographic image-containing film could be digitized into 256 gray levels at 50-microns resolution in less than 30 sec. The scanner was interfaced to a Macintosh II computer through a specially constructed NuBus circuit board and software was developed for autoradiographic data analysis. The system was evaluated by scanning individual films multiple times, then measuring the variability of the digital data between the different scans. Image data were found to be virtually noise free. The coefficient of variation averaged less than 1%, a value significantly exceeding the accuracy of both high-speed, low-resolution, video camera (VC) systems and low-speed, high-resolution, rotating drum densitometers (RDD). Thus, the CCD scanner-Macintosh computer analysis system offers the advantage over VC systems of the ability to digitize entire films containing many autoradiograms, but with much greater speed and accuracy than achievable with RDD scanners

  15. Analysis of high burnup fuel safety issues

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chan Bock; Kim, D. H.; Bang, J. G.; Kim, Y. M.; Yang, Y. S.; Jung, Y. H.; Jeong, Y. H.; Nam, C.; Baik, J. H.; Song, K. W.; Kim, K. S

    2000-12-01

    Safety issues in steady state and transient behavior of high burnup LWR fuel above 50 - 60 MWD/kgU were analyzed. Effects of burnup extension upon fuel performance parameters was reviewed, and validity of both the fuel safety criteria and the performance analysis models which were based upon the lower burnup fuel test results was analyzed. It was found that further tests would be necessary in such areas as fuel failure and dispersion for RIA, and high temperature cladding corrosion and mechanical deformation for LOCA. Since domestic fuels have been irradiated in PWR up to burnup higher than 55 MWD/kgU-rod. avg., it can be said that Korea is in the same situation as the other countries in the high burnup fuel safety issues. Therefore, necessary research areas to be performed in Korea were derived. Considering that post-irradiation examination(PIE) for the domestic fuel of burnup higher than 30 MWD/kgU has not been done so far at all, it is primarily necessary to perform PIE for high burnup fuel, and then simulation tests for RIA and LOCA could be performed by using high burnup fuel specimens. For the areas which can not be performed in Korea, international cooperation will be helpful to obtain the test results. With those data base, safety of high burnup domestic fuels will be confirmed, current fuel safety criteria will be re-evaluated, and finally transient high burnup fuel behavior analysis technology will be developed through the fuel performance analysis code development.

  16. Analysis of high burnup fuel safety issues

    International Nuclear Information System (INIS)

    Lee, Chan Bock; Kim, D. H.; Bang, J. G.; Kim, Y. M.; Yang, Y. S.; Jung, Y. H.; Jeong, Y. H.; Nam, C.; Baik, J. H.; Song, K. W.; Kim, K. S

    2000-12-01

    Safety issues in steady state and transient behavior of high burnup LWR fuel above 50 - 60 MWD/kgU were analyzed. Effects of burnup extension upon fuel performance parameters was reviewed, and validity of both the fuel safety criteria and the performance analysis models which were based upon the lower burnup fuel test results was analyzed. It was found that further tests would be necessary in such areas as fuel failure and dispersion for RIA, and high temperature cladding corrosion and mechanical deformation for LOCA. Since domestic fuels have been irradiated in PWR up to burnup higher than 55 MWD/kgU-rod. avg., it can be said that Korea is in the same situation as the other countries in the high burnup fuel safety issues. Therefore, necessary research areas to be performed in Korea were derived. Considering that post-irradiation examination(PIE) for the domestic fuel of burnup higher than 30 MWD/kgU has not been done so far at all, it is primarily necessary to perform PIE for high burnup fuel, and then simulation tests for RIA and LOCA could be performed by using high burnup fuel specimens. For the areas which can not be performed in Korea, international cooperation will be helpful to obtain the test results. With those data base, safety of high burnup domestic fuels will be confirmed, current fuel safety criteria will be re-evaluated, and finally transient high burnup fuel behavior analysis technology will be developed through the fuel performance analysis code development

  17. High-Bandwidth Tactical-Network Data Analysis in a High-Performance-Computing (HPC) Environment: Packet-Level Analysis

    Science.gov (United States)

    2015-09-01

    individual fragments using the hash-based method. In general, fragments 6 appear in order and relatively close to each other in the file. A fragment...data product derived from the data model is shown in Fig. 5, a Google Earth12 Keyhole Markup Language (KML) file. This product includes aggregate...System BLOb binary large object FPGA field-programmable gate array HPC high-performance computing IP Internet Protocol KML Keyhole Markup Language

  18. Generalized MHD for numerical stability analysis of high-performance plasmas in tokamaks

    International Nuclear Information System (INIS)

    Mikhailovskii, A.B.

    1998-01-01

    provide a basis for development of generalized MHD codes for numerical stability analysis of high-performance plasmas in tokamaks. (author)

  19. Process Measurement Deviation Analysis for Flow Rate due to Miscalibration

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Eunsuk; Kim, Byung Rae; Jeong, Seog Hwan; Choi, Ji Hye; Shin, Yong Chul; Yun, Jae Hee [KEPCO Engineering and Construction Co., Deajeon (Korea, Republic of)

    2016-10-15

    An analysis was initiated to identify the root cause, and the exemption of high static line pressure correction to differential pressure (DP) transmitters was one of the major deviation factors. Also the miscalibrated DP transmitter range was identified as another major deviation factor. This paper presents considerations to be incorporated in the process flow measurement instrumentation calibration and the analysis results identified that the DP flow transmitter electrical output decreased by 3%. Thereafter, flow rate indication decreased by 1.9% resulting from the high static line pressure correction exemption and measurement range miscalibration. After re-calibration, the flow rate indication increased by 1.9%, which is consistent with the analysis result. This paper presents the brief calibration procedures for Rosemount DP flow transmitter, and analyzes possible three cases of measurement deviation including error and cause. Generally, the DP transmitter is required to be calibrated with precise process input range according to the calibration procedure provided for specific DP transmitter. Especially, in case of the DP transmitter installed in high static line pressure, it is important to correct the high static line pressure effect to avoid the inherent systematic error for Rosemount DP transmitter. Otherwise, failure to notice the correction may lead to indicating deviation from actual value.

  20. High performance homes

    DEFF Research Database (Denmark)

    Beim, Anne; Vibæk, Kasper Sánchez

    2014-01-01

    Can prefabrication contribute to the development of high performance homes? To answer this question, this chapter defines high performance in more broadly inclusive terms, acknowledging the technical, architectural, social and economic conditions under which energy consumption and production occur....... Consideration of all these factors is a precondition for a truly integrated practice and as this chapter demonstrates, innovative project delivery methods founded on the manufacturing of prefabricated buildings contribute to the production of high performance homes that are cost effective to construct, energy...

  1. High rate, fast timing Glass RPC for the high $\\eta$ CMS muon detectors

    CERN Document Server

    INSPIRE-00185093; Lagarde, François; Laktineh, Imad; Buridon, Victor; Chen, Xiushan; Combaret, Christophe; Eynard, Alexis; Germani, Lionel; Grenier, Gerald; Mathez, Hervé; Mirabito, Laurent; Petrukhin, Alexei; Steen, Arnaud; Tromeur, William; Wang, Yi; Gong, A.; Moreau, Nathalie; de la Taille, Christophe; Dulucq, Fréderic

    2017-02-11

    The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6 \\cdot 10^{34}$ cm$^{-2}$s$^{-1}$. The region of the forward muon spectrometer ($|\\eta| > 1.6$) is not equipped with RPC stations. The increase of the expected particles rate up to 2 kHz/cm$^2$ ( including a safety factor 3 ) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The actual RPC technology of CMS cannot sustain the expected background level. A new generation Glass-RPC (GRPC) using low resistivity glass (LR) is proposed to equip at least the two most far away of the four high eta muon stations of CMS. The design of small size prototypes and the studies of their performances under high rate particles flux is presented.

  2. Least reliable bits coding (LRBC) for high data rate satellite communications

    Science.gov (United States)

    Vanderaar, Mark; Budinger, James; Wagner, Paul

    1992-01-01

    LRBC, a bandwidth efficient multilevel/multistage block-coded modulation technique, is analyzed. LRBC uses simple multilevel component codes that provide increased error protection on increasingly unreliable modulated bits in order to maintain an overall high code rate that increases spectral efficiency. Soft-decision multistage decoding is used to make decisions on unprotected bits through corrections made on more protected bits. Analytical expressions and tight performance bounds are used to show that LRBC can achieve increased spectral efficiency and maintain equivalent or better power efficiency compared to that of BPSK. The relative simplicity of Galois field algebra vs the Viterbi algorithm and the availability of high-speed commercial VLSI for block codes indicates that LRBC using block codes is a desirable method for high data rate implementations.

  3. [Incidence rate of adverse reaction/event by Qingkailing injection: a Meta-analysis of single rate].

    Science.gov (United States)

    Ai, Chun-ling; Xie, Yan-ming; Li, Ming-quan; Wang, Lian-xin; Liao, Xing

    2015-12-01

    To systematically review the incidence rate of adverse drug reaction/event by Qingkailing injection. Such databases as the PubMed, EMbase, the Cochrane library, CNKI, VIP WanFang data and CBM were searched by computer from foundation to July 30, 2015. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data and cross check data. Then, Meta-analysis was performed by using the R 3.2.0 software, subgroup sensitivity analysis was performed based on age, mode of medicine, observation time and research quality. Sixty-three studies involving 9,793 patients with Qingkailing injection were included, 367 cases of adverse reactions/events were reported in total. The incidence rate of adverse reaction in skin and mucosa group was 2% [95% CI (0.02; 0.03)]; the digestive system adverse reaction was 6% [95% CI(0.05; 0.07); the injection site adverse reaction was 4% [95% CI (0.02; 0.07)]. In the digestive system as the main types of adverse reactions/events, incidence of children and adults were 4.6% [0.021 1; 0.097 7] and 6.9% [0.053 5; 0.089 8], respectively. Adverse reactions to skin and mucous membrane damage as the main performance/event type, the observation time > 7 days and ≤ 7 days incidence of 3% [0.012 9; 0.068 3] and 1.9% [0.007 8; 0.046 1], respectively. Subgroup analysis showed that different types of adverse reactions, combination in the incidence of adverse reactions/events were higher than that of single drug, the difference was statistically significant (P reactions occur, and clinical rational drug use, such as combination, age and other fators, and the influence factors vary in different populations. Therefore, clinical doctors for children and the elderly use special care was required for a clear and open spirit injection, the implementation of individualized medication.

  4. Determination of dasatinib in the tablet dosage form by ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis.

    Science.gov (United States)

    Gonzalez, Aroa Garcia; Taraba, Lukáš; Hraníček, Jakub; Kozlík, Petr; Coufal, Pavel

    2017-01-01

    Dasatinib is a novel oral prescription drug proposed for treating adult patients with chronic myeloid leukemia. Three analytical methods, namely ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis, were developed, validated, and compared for determination of the drug in the tablet dosage form. The total analysis time of optimized ultra high performance liquid chromatography and capillary zone electrophoresis methods was 2.0 and 2.2 min, respectively. Direct ultraviolet detection with detection wavelength of 322 nm was employed in both cases. The optimized sequential injection analysis method was based on spectrophotometric detection of dasatinib after a simple colorimetric reaction with folin ciocalteau reagent forming a blue-colored complex with an absorbance maximum at 745 nm. The total analysis time was 2.5 min. The ultra high performance liquid chromatography method provided the lowest detection and quantitation limits and the most precise and accurate results. All three newly developed methods were demonstrated to be specific, linear, sensitive, precise, and accurate, providing results satisfactorily meeting the requirements of the pharmaceutical industry, and can be employed for the routine determination of the active pharmaceutical ingredient in the tablet dosage form. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Ischemic risk stratification by means of multivariate analysis of the heart rate variability

    International Nuclear Information System (INIS)

    Valencia, José F; Vallverdú, Montserrat; Caminal, Pere; Porta, Alberto; Voss, Andreas; Schroeder, Rico; Vázquez, Rafael; Bayés de Luna, Antonio

    2013-01-01

    In this work, a univariate and multivariate statistical analysis of indexes derived from heart rate variability (HRV) was conducted to stratify patients with ischemic dilated cardiomyopathy (IDC) in cardiac risk groups. Indexes conditional entropy, refined multiscale entropy (RMSE), detrended fluctuation analysis, time and frequency analysis, were applied to the RR interval series (beat-to-beat series), for single and multiscale complexity analysis of the HRV in IDC patients. Also, clinical parameters were considered. Two different end-points after a follow-up of three years were considered: (i) analysis A, with 151 survivor patients as a low risk group and 13 patients that suffered sudden cardiac death as a high risk group; (ii) analysis B, with 192 survivor patients as a low risk group and 30 patients that suffered cardiac mortality as a high risk group. A univariate and multivariate linear discriminant analysis was used as a statistical technique for classifying patients in risk groups. Sensitivity (Sen) and specificity (Spe) were calculated as diagnostic criteria in order to evaluate the performance of the indexes and their linear combinations. Sen and Spe values of 80.0% and 72.9%, respectively, were obtained during daytime by combining one clinical parameter and one index from RMSE, and during nighttime Sen = 80% and Spe = 73.4% were attained by combining one clinical factor and two indexes from RMSE. In particular, relatively long time scales were more relevant for classifying patients into risk groups during nighttime, while during daytime shorter scales performed better. The results suggest that the left atrial size, indexed to body surface and RMSE indexes are those that allow enhanced classification of ischemic patients in their respective risk groups, confirming that a single measurement is not enough to fully characterize ischemic risk patients and the clinical relevance of HRV complexity measures. (paper)

  6. A Simple and High Performing Rate Control Initialization Method for H.264 AVC Coding Based on Motion Vector Map and Spatial Complexity at Low Bitrate

    Directory of Open Access Journals (Sweden)

    Yalin Wu

    2014-01-01

    Full Text Available The temporal complexity of video sequences can be characterized by motion vector map which consists of motion vectors of each macroblock (MB. In order to obtain the optimal initial QP (quantization parameter for the various video sequences which have different spatial and temporal complexities, this paper proposes a simple and high performance initial QP determining method based on motion vector map and temporal complexity to decide an initial QP in given target bit rate. The proposed algorithm produces the reconstructed video sequences with outstanding and stable quality. For any video sequences, the initial QP can be easily determined from matrices by target bit rate and mapped spatial complexity using proposed mapping method. Experimental results show that the proposed algorithm can show more outstanding objective and subjective performance than other conventional determining methods.

  7. Analysis of physical match performance in English Premier League soccer referees with particular reference to first half and player work rates.

    Science.gov (United States)

    Weston, Matthew; Castagna, Carlo; Impellizzeri, Franco M; Rampinini, Ermanno; Abt, Grant

    2007-12-01

    The aim of the present study was to examine the influence of first half activity, overall match intensity and seasonal variation on the physical match performances of English Premier League football referees. Match analysis data was collected using the Prozone match analysis system from 19 full-time professional referees during a total of 254 matches in the 2004-2005 season. Physical match performances were classified into three separate categories: 1, total distance covered (TD); 2, high-intensity running distance (running speed>5.5m/s, HIR); 3, average distance from infringements (DI). Using these match activity variables the influence of first half TD and HIR distances on second half activities and also the influence of players' match activities upon the referees' physical match performances were examined. The main finding of the present study was that the physical match performances of the referees were partly related to those of the players, in that the referees' HIR correlated with players' HIR (r=0.43, pphysical match performance of the referee. Further examination is required as to whether reduced physical performances in the second half of matches are a consequence of referee fatigue, tactical strategies on behalf of the referee or reduced player match activities resulting in a slower tempo of match.

  8. Sensitivity Analysis of Corrosion Rate Prediction Models Utilized for Reinforced Concrete Affected by Chloride

    Science.gov (United States)

    Siamphukdee, Kanjana; Collins, Frank; Zou, Roger

    2013-06-01

    Chloride-induced reinforcement corrosion is one of the major causes of premature deterioration in reinforced concrete (RC) structures. Given the high maintenance and replacement costs, accurate modeling of RC deterioration is indispensable for ensuring the optimal allocation of limited economic resources. Since corrosion rate is one of the major factors influencing the rate of deterioration, many predictive models exist. However, because the existing models use very different sets of input parameters, the choice of model for RC deterioration is made difficult. Although the factors affecting corrosion rate are frequently reported in the literature, there is no published quantitative study on the sensitivity of predicted corrosion rate to the various input parameters. This paper presents the results of the sensitivity analysis of the input parameters for nine selected corrosion rate prediction models. Three different methods of analysis are used to determine and compare the sensitivity of corrosion rate to various input parameters: (i) univariate regression analysis, (ii) multivariate regression analysis, and (iii) sensitivity index. The results from the analysis have quantitatively verified that the corrosion rate of steel reinforcement bars in RC structures is highly sensitive to corrosion duration time, concrete resistivity, and concrete chloride content. These important findings establish that future empirical models for predicting corrosion rate of RC should carefully consider and incorporate these input parameters.

  9. On the response of rubbers at high strain rates.

    Energy Technology Data Exchange (ETDEWEB)

    Niemczura, Johnathan Greenberg (University of Texas-Austin)

    2010-02-01

    In this report, we examine the propagation of tensile waves of finite deformation in rubbers through experiments and analysis. Attention is focused on the propagation of one-dimensional dispersive and shock waves in strips of latex and nitrile rubber. Tensile wave propagation experiments were conducted at high strain-rates by holding one end fixed and displacing the other end at a constant velocity. A high-speed video camera was used to monitor the motion and to determine the evolution of strain and particle velocity in the rubber strips. Analysis of the response through the theory of finite waves and quantitative matching between the experimental observations and analytical predictions was used to determine an appropriate instantaneous elastic response for the rubbers. This analysis also yields the tensile shock adiabat for rubber. Dispersive waves as well as shock waves are also observed in free-retraction experiments; these are used to quantify hysteretic effects in rubber.

  10. High-Performance Buildings – Value, Messaging, Financial and Policy Mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    McCabe, Molly

    2011-02-22

    At the request of the Pacific Northwest National Laboratory, an in-depth analysis of the rapidly evolving state of real estate investments, high-performance building technology, and interest in efficiency was conducted by HaydenTanner, LLC, for the U.S. Department of Energy (DOE) Building Technologies Program. The analysis objectives were • to evaluate the link between high-performance buildings and their market value • to identify core messaging to motivate owners, investors, financiers, and others in the real estate sector to appropriately value and deploy high-performance strategies and technologies across new and existing buildings • to summarize financial mechanisms that facilitate increased investment in these buildings. To meet these objectives, work consisted of a literature review of relevant writings, examination of existing and emergent financial and policy mechanisms, interviews with industry stakeholders, and an evaluation of the value implications through financial modeling. This report documents the analysis methodology and findings, conclusion and recommendations. Its intent is to support and inform the DOE Building Technologies Program on policy and program planning for the financing of high-performance new buildings and building retrofit projects.

  11. Time and position resolution of high granularity, high counting rate MRPC for the inner zone of the CBM-TOF wall

    CERN Document Server

    Petriş, M.

    2016-09-13

    Multi-gap RPC prototypes with readout on a multi-strip electrode were developed for the small polar angle region of the CBM-TOF subdetector, the most demanding zone in terms of granularity and counting rate. The prototypes are based on low resistivity ($\\sim$10$^{10}$ $\\Omega$cm) glass electrodes for performing in high counting rate environment. The strip width/pitch size was chosen such to fulfill the impedance matching with the front-end electronics and the granularity requirements of the innermost zone of the CBM-TOF wall. The in-beam tests using secondary particles produced in heavy ion collisions on a Pb target at SIS18 - GSI Darmstadt and SPS - CERN were focused on the performance of the prototype in conditions similar to the ones expected at SIS100/FAIR. An efficiency larger than 98\\% and a system time resolution in the order of 70~-~80~ps were obtained in high counting rate and high multiplicity environment.

  12. Consideration of wear rates at high velocity

    Science.gov (United States)

    Hale, Chad S.

    The development of the research presented here is one in which high velocity relative sliding motion between two bodies in contact has been considered. Overall, the wear environment is truly three-dimensional. The attempt to characterize three-dimensional wear was not economically feasible because it must be analyzed at the micro-mechanical level to get results. Thus, an engineering approximation was carried out. This approximation was based on a metallographic study identifying the need to include viscoplasticity constitutive material models, coefficient of friction, relationships between the normal load and velocity, and the need to understand wave propagation. A sled test run at the Holloman High Speed Test Track (HHSTT) was considered for the determination of high velocity wear rates. In order to adequately characterize high velocity wear, it was necessary to formulate a numerical model that contained all of the physical events present. The experimental results of a VascoMax 300 maraging steel slipper sliding on an AISI 1080 steel rail during a January 2008 sled test mission were analyzed. During this rocket sled test, the slipper traveled 5,816 meters in 8.14 seconds and reached a maximum velocity of 1,530 m/s. This type of environment was never considered previously in terms of wear evaluation. Each of the features of the metallography were obtained through micro-mechanical experimental techniques. The byproduct of this analysis is that it is now possible to formulate a model that contains viscoplasticity, asperity collisions, temperature and frictional features. Based on the observations of the metallographic analysis, these necessary features have been included in the numerical model, which makes use of a time-dynamic program which follows the movement of a slipper during its experimental test run. The resulting velocity and pressure functions of time have been implemented in the explicit finite element code, ABAQUS. Two-dimensional, plane strain models

  13. Development of amplifier and shaper for high-rate MWPC

    International Nuclear Information System (INIS)

    Kamiji, Ichinori; Nanjo, Hajime; Kawasaki, Naoki; Maeda, Yosuke; Naito, Daichi; Seki, Shigeto; Nakagiri, Kota; Sasao, Noboru; Nomura, Tadashi

    2015-01-01

    A multi-wire proportional chamber (MWPC) will be used as an in-beam charged particle detector for the J-PARC E14 (KOTO) experiment. The maximum counting rate of the MWPC is expected to be up to 1 MHz per channel due to the high neutron and photon flux, expected to be 1 GHz for the 30 x 30 cm"2 area. An amplifier to cope with such high counting-rate is required. We developed a prototype of such amplifier, which has a charge preamplifier with the integration time of 3 ns and a pulse shaping part with three pole-zero cancellation networks. The shaper reduced the characteristic long tail lasting tens of microseconds in the signal of MWPC to 150 ns. Its performance has been tested by using a single-channel MWPC which has almost the same geometrical parameters as the MWPC to be installed in the KOTO experiment. (author)

  14. Integrated High-Rate Transition Radiation Detector and Tracking Chamber for the LHC

    CERN Multimedia

    2002-01-01

    % RD-6 \\\\ \\\\Over the past five years, RD-6 has developed a transition radiation detector and charged particle tracker for high rate operation at LHC. The detector elements are based on C-fibre reinforced kapton straw tubes of 4~mm diameter filled with a Xenon gas mixture. Detailed measurements with and without magnetic field have been performed in test beams, and in particular have demonstrated the possibility of operating straw tubes at very high rate (up to 20~MHz) with accurate drift-time measurement accuracy. A full-scale engineering prototype containing 10~000 straws is presently under assembly and will be accurately measured with a powerful X-ray tube. Integrated front-end electronics with fast readout have been designed and successfully operated in test beam. \\\\ \\\\Finally extensive simulations performed for ATLAS have shown that such a detector will provide powerful pattern recognition, accurate momentum measurements, efficient level-2 triggering and excellent electron identification, even at the highe...

  15. Development of bonded semiconductor device for high counting rate high efficiency photon detectors

    International Nuclear Information System (INIS)

    Kanno, Ikuo

    2008-01-01

    We are trying to decrease dose exposure in medical diagnosis by way of measuring the energy of X-rays. For this purpose, radiation detectors for X-ray energy measurement with high counting rate should be developed. Direct bonding of Si wafers was carried out to make a radiation detector, which had separated X-ray absorber and detector. The resistivity of bonding interface was estimated with the results of four-probe measurements and model calculations. Direct bonding of high resistivity p and n-Si wafers was also performed. The resistance of the pn bonded diode was 0.7 MΩ. The resistance should be increased in the future. (author)

  16. Transperineal high-dose-rate interstitial radiation therapy in the management of gynecologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Itami, Jun; Hara, Ryuseke; Kozuka, Takuyou; Yamashita, Hideomi; Nakajima, Kaori; Shibata, Kouji; Abe, Yoshihisa; Fuse, Masashi; Ito, Masashi [International Medical Center of Japan, Tokyo (Japan). Dept. of Radiation Therapy and Oncology

    2003-11-01

    Background: High-dose-rate interstitial radiation therapy is a newly introduced modality, and its role in the management of gynecologic malignancies remains to be studied. Clinical experience in high-dose-rate interstitial radiation therapy was retrospectively investigated. Patients and Methods: Eight patients with primary and nine with recurrent gynecologic malignancies underwent high-dose-rate interstitial radiation therapy with/without external-beam irradiation. Fractional dose of the high-dose-rate interstitial radiation therapy ranged between 4 and 6 Gy with total doses of 15-54 Gy. Interstitial irradiation was performed twice daily with an interval of > 6 h. Results: 2-year local control rate was 75% for primary treatment and 47% for treatment of recurrence (p = 0.46). Maximum tumor size had a statistically significant impact on local control (p < 0.002). Grade 2 and 4 late complications were seen in five patients, and the incidence was significantly higher in patients with a larger volume enclosed by the prescribed fractional dose of high-dose-rate interstitial radiation therapy. The incidence of grade 2 and 4 complications at 18 months was 78% and 0% with a volume > 100 cm{sup 3} and {<=} 100 cm{sup 3}, respectively (p < 0.04). Conclusion: Although high-dose-rate interstitial radiation therapy is a promising modality, it must be applied cautiously to patients with bulky tumors because of the high incidence of serious complications. (orig.)

  17. Business Metrics for High-Performance Homes: A Colorado Springs Case Study

    Energy Technology Data Exchange (ETDEWEB)

    Beach, R. [IBACOS, Inc, Pittsburgh, PA (United States); Jones, A. [IBACOS, Inc, Pittsburgh, PA (United States)

    2016-04-26

    This report explores the correlation between energy efficiency and the business success of home builders by examining a data set of builders and homes in the Colorado Springs, Colorado, market between 2006 and 2014. During this time, the Great Recession of 2007 to 2009 occurred, and new-home sales plummeted both nationally and in Colorado Springs. What is evident from an analysis of builders and homes in Colorado Springs is that builders who had Home Energy Rating System (HERS) ratings performed on some or all of their homes during the Recession remained in business during this challenging economic period. Many builders who did not have HERS ratings performed on their homes at that time went out of business or left the area. From the analysis presented in this report, it is evident that a correlation exists between energy efficiency and the business success of home builders, although the reasons for this correlation remain largely anecdotal and not yet clearly understood.

  18. Thirty-Day Readmission Rates in Orthopedics: A Systematic Review and Meta-Analysis

    Science.gov (United States)

    Bernatz, James T.; Tueting, Jonathan L.; Anderson, Paul A.

    2015-01-01

    Background Hospital readmission rates are being used to evaluate performance. A survey of the present rates is needed before policies can be developed to decrease incidence of readmission. We address three questions: What is the present rate of 30-day readmission in orthopedics? How do factors such as orthopedic specialty, data source, patient insurance, and time of data collection affect the 30-day readmission rate? What are the causes and risk factors for 30-day readmissions? Methods/Findings A review was first registered with Prospero (CRD42014010293, 6/17/2014) and a meta-analysis was performed to assess the current 30-day readmission rate in orthopedics. Studies published after 2006 were retrieved, and 24 studies met the inclusion criteria. The 30-day readmission rate was extrapolated from each study along with the orthopedic subspecialty, data source, patient insurance, time of collection, patient demographics, and cause of readmission. A sensitivity analysis was completed on the stratified groups. The overall 30-day readmission rate across all orthopedics was 5.4 percent (95% confidence interval: 4.8,6.0). There was no significant difference between subspecialties. Studies that retrieved data from a multicenter registry had a lower 30-day readmission rate than those reporting data from a single hospital or a large national database. Patient populations that only included Medicare patients had a higher 30-day readmission rate than populations of all insurance. The 30-day readmission rate has decreased in the past ten years. Age, length of stay, discharge to skilled nursing facility, increased BMI, ASA score greater than 3, and Medicare/Medicaid insurance showed statistically positive correlation with increased 30-day readmissions in greater than 75 percent of studies. Surgical site complications accounted for 46 percent of 30-day readmissions. Conclusions This meta-analysis shows the present rate of 30-day readmissions in orthopedics. Demonstrable

  19. Three-Axis Attitude Estimation With a High-Bandwidth Angular Rate Sensor

    Science.gov (United States)

    Bayard, David S.; Green, Joseph J.

    2013-01-01

    A continuing challenge for modern instrument pointing control systems is to meet the increasingly stringent pointing performance requirements imposed by emerging advanced scientific, defense, and civilian payloads. Instruments such as adaptive optics telescopes, space interferometers, and optical communications make unprecedented demands on precision pointing capabilities. A cost-effective method was developed for increasing the pointing performance for this class of NASA applications. The solution was to develop an attitude estimator that fuses star tracker and gyro measurements with a high-bandwidth angular rotation sensor (ARS). An ARS is a rate sensor whose bandwidth extends well beyond that of the gyro, typically up to 1,000 Hz or higher. The most promising ARS sensor technology is based on a magnetohydrodynamic concept, and has recently become available commercially. The key idea is that the sensor fusion of the star tracker, gyro, and ARS provides a high-bandwidth attitude estimate suitable for supporting pointing control with a fast-steering mirror or other type of tip/tilt correction for increased performance. The ARS is relatively inexpensive and can be bolted directly next to the gyro and star tracker on the spacecraft bus. The high-bandwidth attitude estimator fuses an ARS sensor with a standard three-axis suite comprised of a gyro and star tracker. The estimation architecture is based on a dual-complementary filter (DCF) structure. The DCF takes a frequency- weighted combination of the sensors such that each sensor is most heavily weighted in a frequency region where it has the lowest noise. An important property of the DCF is that it avoids the need to model disturbance torques in the filter mechanization. This is important because the disturbance torques are generally not known in applications. This property represents an advantage over the prior art because it overcomes a weakness of the Kalman filter that arises when fusing more than one rate

  20. General Purpose Graphics Processing Unit Based High-Rate Rice Decompression and Reed-Solomon Decoding

    Energy Technology Data Exchange (ETDEWEB)

    Loughry, Thomas A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-02-01

    As the volume of data acquired by space-based sensors increases, mission data compression/decompression and forward error correction code processing performance must likewise scale. This competency development effort was explored using the General Purpose Graphics Processing Unit (GPGPU) to accomplish high-rate Rice Decompression and high-rate Reed-Solomon (RS) decoding at the satellite mission ground station. Each algorithm was implemented and benchmarked on a single GPGPU. Distributed processing across one to four GPGPUs was also investigated. The results show that the GPGPU has considerable potential for performing satellite communication Data Signal Processing, with three times or better performance improvements and up to ten times reduction in cost over custom hardware, at least in the case of Rice Decompression and Reed-Solomon Decoding.

  1. Germination, growth rates, and electron microscope analysis of tomato seeds flown on the LDEF

    Science.gov (United States)

    Hammond, Ernest C., Jr.; Bridgers, Kevin; Brown, Cecelia Wright

    1995-01-01

    The tomato seeds were flown in orbit aboard the Long Duration Exposure Facility (LDEF) for nearly six years. During this time, the tomato seeds received an abundant exposure to cosmic radiation and solar wind. Upon the return of the LDEF to earth, the seeds were distributed throughout the United States and 30 foreign countries for analysis. The purpose of the experiment was to determine the long term effect of cosmic rays on living tissue. Our university analysis included germination and growth rates as well as Scanning Electron Microscopy and X-ray analysis of the control as well as Space-exposed tomato seeds. In analyzing the seeds under the Electron Microscope, usual observations were performed on the nutritional and epidermis layer of the seed. These layers appeared to be more porous in the Space-exposed seeds than on the Earth-based control seeds. This unusual characteristic may explain the increases in the space seeds growth pattern. (Several test results show that the Space-exposed seeds germinate sooner than the Earth-Based seeds. Also, the Space-exposed seeds grew at a faster rate). The porous nutritional region may allow the seeds to receive necessary nutrients and liquids more readily, thus enabling the plant to grow at a faster rate. Roots, leaves and stems were cut into small sections and mounted. After sputter coating the specimens with Argon/Gold Palladium Plasma, they were ready to be viewed under the Electron Microscope. Many micrographs were taken. The X-ray analysis displayed possible identifications of calcium, potassium, chlorine, copper, aluminum, silicon, phosphate, carbon, and sometimes sulfur and iron. The highest concentrations were shown in potassium and calcium. The Space-exposed specimens displayed a high concentration of copper and calcium in the two specimens. There was a significantly high concentration of copper in the Earth-based specimens, whereas there was no copper in the Space-exposed specimens.

  2. High Performance Numerical Computing for High Energy Physics: A New Challenge for Big Data Science

    International Nuclear Information System (INIS)

    Pop, Florin

    2014-01-01

    Modern physics is based on both theoretical analysis and experimental validation. Complex scenarios like subatomic dimensions, high energy, and lower absolute temperature are frontiers for many theoretical models. Simulation with stable numerical methods represents an excellent instrument for high accuracy analysis, experimental validation, and visualization. High performance computing support offers possibility to make simulations at large scale, in parallel, but the volume of data generated by these experiments creates a new challenge for Big Data Science. This paper presents existing computational methods for high energy physics (HEP) analyzed from two perspectives: numerical methods and high performance computing. The computational methods presented are Monte Carlo methods and simulations of HEP processes, Markovian Monte Carlo, unfolding methods in particle physics, kernel estimation in HEP, and Random Matrix Theory used in analysis of particles spectrum. All of these methods produce data-intensive applications, which introduce new challenges and requirements for ICT systems architecture, programming paradigms, and storage capabilities.

  3. Palaeohistological Evidence for Ancestral High Metabolic Rate in Archosaurs.

    Science.gov (United States)

    Legendre, Lucas J; Guénard, Guillaume; Botha-Brink, Jennifer; Cubo, Jorge

    2016-11-01

    Metabolic heat production in archosaurs has played an important role in their evolutionary radiation during the Mesozoic, and their ancestral metabolic condition has long been a matter of debate in systematics and palaeontology. The study of fossil bone histology provides crucial information on bone growth rate, which has been used to indirectly investigate the evolution of thermometabolism in archosaurs. However, no quantitative estimation of metabolic rate has ever been performed on fossils using bone histological features. Moreover, to date, no inference model has included phylogenetic information in the form of predictive variables. Here we performed statistical predictive modeling using the new method of phylogenetic eigenvector maps on a set of bone histological features for a sample of extant and extinct vertebrates, to estimate metabolic rates of fossil archosauromorphs. This modeling procedure serves as a case study for eigenvector-based predictive modeling in a phylogenetic context, as well as an investigation of the poorly known evolutionary patterns of metabolic rate in archosaurs. Our results show that Mesozoic theropod dinosaurs exhibit metabolic rates very close to those found in modern birds, that archosaurs share a higher ancestral metabolic rate than that of extant ectotherms, and that this derived high metabolic rate was acquired at a much more inclusive level of the phylogenetic tree, among non-archosaurian archosauromorphs. These results also highlight the difficulties of assigning a given heat production strategy (i.e., endothermy, ectothermy) to an estimated metabolic rate value, and confirm findings of previous studies that the definition of the endotherm/ectotherm dichotomy may be ambiguous. © The Author(s) 2016. Published by Oxford University Press, on behalf of the Society of Systematic Biologists. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Relationship between Self-Rated Health and Lifestyle and Food Habits in Japanese High School Students.

    Science.gov (United States)

    Osera, Tomoko; Awai, Mitsuyo; Kobayashi, Misako; Tsutie, Setsuko; Kurihara, Nobutaka

    2017-10-18

    Self-rated health (SRH), a subjective assessment of health status, is extensively used in the field of public health. It is an important and valid measure that is strongly related to morbidity, mortality, longevity and health status. Adolescence is a crucial period for the formation of health status, because health-risk behaviours (e.g., skipping breakfast) are often established during this period. In this study, we investigated the relationship of SRH with lifestyle and eating habits in Japanese high school students. In this study, 1296 students aged 16-18 years from 11 high schools in Japan participated. A questionnaire was administered to these participants that included a question on SRH, five questions on demographic characteristics, six questions on lifestyle items (e.g., wake-up time), five questions on miscellaneous health issues (e.g., anorexia), and 25 questions on food habits and attitudes towards food. We examined the differences between self-rated healthy and unhealthy groups using logistic regression analysis adjusted for gender and age. A dichotomy regression analysis was performed using a stepwise elimination method. Of the 1296 respondents, 16.7% reported feeling unhealthy, 57.7% of whom were females. The self-rated healthy group had a higher frequency of eating breakfast (odds ratio (OR): 2.13; confidence interval (CI): 1.07-4.24) and liked home meals to a greater extent (OR: 3.12; CI: 1.27-7.65) than the self-rated unhealthy group. The two groups did not differ significantly in terms of other lifestyle factors or unidentified complaints. Our results suggest that liking home meals during adolescence may lead to the development of good eating habits, i.e., eating breakfast, and better SRH.

  5. Performance analysis and improvement of WPAN MAC for home networks.

    Science.gov (United States)

    Mehta, Saurabh; Kwak, Kyung Sup

    2010-01-01

    The wireless personal area network (WPAN) is an emerging wireless technology for future short range indoor and outdoor communication applications. The IEEE 802.15.3 medium access control (MAC) is proposed to coordinate the access to the wireless medium among the competing devices, especially for short range and high data rate applications in home networks. In this paper we use analytical modeling to study the performance analysis of WPAN (IEEE 802.15.3) MAC in terms of throughput, efficient bandwidth utilization, and delay with various ACK policies under error channel condition. This allows us to introduce a K-Dly-ACK-AGG policy, payload size adjustment mechanism, and Improved Backoff algorithm to improve the performance of the WPAN MAC. Performance evaluation results demonstrate the impact of our improvements on network capacity. Moreover, these results can be very useful to WPAN application designers and protocol architects to easily and correctly implement WPAN for home networking.

  6. Performance Analysis and Improvement of WPAN MAC for Home Networks

    Directory of Open Access Journals (Sweden)

    Saurabh Mehta

    2010-03-01

    Full Text Available The wireless personal area network (WPAN is an emerging wireless technology for future short range indoor and outdoor communication applications. The IEEE 802.15.3 medium access control (MAC is proposed to coordinate the access to the wireless medium among the competing devices, especially for short range and high data rate applications in home networks. In this paper we use analytical modeling to study the performance analysis of WPAN (IEEE 802.15.3 MAC in terms of throughput, efficient bandwidth utilization, and delay with various ACK policies under error channel condition. This allows us to introduce a K-Dly-ACK-AGG policy, payload size adjustment mechanism, and Improved Backoff algorithm to improve the performance of the WPAN MAC. Performance evaluation results demonstrate the impact of our improvements on network capacity. Moreover, these results can be very useful to WPAN application designers and protocol architects to easily and correctly implement WPAN for home networking.

  7. Comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones.

    Science.gov (United States)

    Carnes, Stephanie; O'Brien, Stacey; Szewczak, Angelica; Tremeau-Cayel, Lauriane; Rowe, Walter F; McCord, Bruce; Lurie, Ira S

    2017-09-01

    A comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones has been conducted. Nine different mixtures of bath salts were analyzed in this study. The three different chromatographic techniques were examined using a general set of controlled synthetic cathinones as well as a variety of other synthetic cathinones that exist as positional isomers. Overall 35 different synthetic cathinones were analyzed. A variety of column types and chromatographic modes were examined for developing each separation. For the ultra high performance supercritical fluid chromatography separations, analyses were performed using a series of Torus and Trefoil columns with either ammonium formate or ammonium hydroxide as additives, and methanol, ethanol or isopropanol organic solvents as modifiers. Ultra high performance liquid chromatographic separations were performed in both reversed phase and hydrophilic interaction chromatographic modes using SPP C18 and SPP HILIC columns. Gas chromatography separations were performed using an Elite-5MS capillary column. The orthogonality of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography was examined using principal component analysis. For the best overall separation of synthetic cathinones, the use of ultra high performance supercritical fluid chromatography in combination with gas chromatography is recommended. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Rewarded remembering: dissociations between self-rated motivation and memory performance.

    Science.gov (United States)

    Ngaosuvan, Leonard; Mäntylä, Timo

    2005-08-01

    People often claim that they perform better in memory performance tasks when they are more motivated. However, past research has shown minimal effects of motivation on memory performance when factors contributing to item-specific biases during encoding and retrieval are taken into account. The purpose of the present study was to examine the generality of this apparent dissociation by using more sensitive measures of experienced motivation and memory performance. Extrinsic motivation was manipulated through competition instructions, and subjective ratings of intrinsic and extrinsic motivation were obtained before and after study instructions. Participants studied a series of words, and memory performance was assessed by content recall (Experiment 1) and source recall (Experiment 2). Both experiments showed dissociation between subjective ratings of extrinsic motivation and actual memory performance, so that competition increased self-rated extrinsic motivation but had no effects on memory performance, including source recall. Inconsistent with most people's expectations, the findings suggest that extrinsic motivation has minimal effects on memory performance.

  9. High perfomance liquid chromatography fingerprint analysis for quality control of brotowali (Tinospora crispa)

    Science.gov (United States)

    Syarifah, V. B.; Rafi, M.; Wahyuni, W. T.

    2017-05-01

    Brotowali (Tinospora crispa) is widely used in Indonesia as ingredient of herbal medicine formulation. To ensure the quality, safety, and efficacy of herbal medicine products, its chemical constituents should be continuously evaluated. High performance liquid chromatography (HPLC) fingerprint is one of powerful technique for this quality control process. In this study, HPLC fingerprint analysis method was developed for quality control of brotowali. HPLC analysis was performed in C18 column and detection was performed using photodiode array detector. The optimum mobile phase for brotowali fingerprint was acetonitrile (ACN) and 0.1% formic acid in gradient elution mode at a flow rate of 1 mL/min. The number of peaks detected in HPLC fingerprint of brotowali was 32 peaks and 23 peaks for stems and leaves, respectively. Berberine as marker compound was detected at retention time of 20.525 minutes. Evaluation of analytical performance including precision, reproducibility, and stability prove that this HPLC fingerprint analysis was reliable and could be applied for quality control of brotowali.

  10. Constrained independent component analysis approach to nonobtrusive pulse rate measurements

    Science.gov (United States)

    Tsouri, Gill R.; Kyal, Survi; Dianat, Sohail; Mestha, Lalit K.

    2012-07-01

    Nonobtrusive pulse rate measurement using a webcam is considered. We demonstrate how state-of-the-art algorithms based on independent component analysis suffer from a sorting problem which hinders their performance, and propose a novel algorithm based on constrained independent component analysis to improve performance. We present how the proposed algorithm extracts a photoplethysmography signal and resolves the sorting problem. In addition, we perform a comparative study between the proposed algorithm and state-of-the-art algorithms over 45 video streams using a finger probe oxymeter for reference measurements. The proposed algorithm provides improved accuracy: the root mean square error is decreased from 20.6 and 9.5 beats per minute (bpm) for existing algorithms to 3.5 bpm for the proposed algorithm. An error of 3.5 bpm is within the inaccuracy expected from the reference measurements. This implies that the proposed algorithm provided performance of equal accuracy to the finger probe oximeter.

  11. Understanding the biological activity of high rate algae ponds through the calculation of oxygen balances.

    Science.gov (United States)

    Arbib, Zouhayr; de Godos Crespo, Ignacio; Corona, Enrique Lara; Rogalla, Frank

    2017-06-01

    Microalgae culture in high rate algae ponds (HRAP) is an environmentally friendly technology for wastewater treatment. However, for the implementation of these systems, a better understanding of the oxygenation potential and the influence of climate conditions is required. In this work, the rates of oxygen production, consumption, and exchange with the atmosphere were calculated under varying conditions of solar irradiance and dilution rate during six months of operation in a real scale unit. This analysis allowed determining the biological response of these dynamic systems. The rates of oxygen consumption measured were considerably higher than the values calculated based on the organic loading rate. The response to light intensity in terms of oxygen production in the bioreactor was described with one of the models proposed for microalgae culture in dense concentrations. This model is based on the availability of light inside the culture and the specific response of microalgae to this parameter. The specific response to solar radiation intensity showed a reasonable stability in spite of the fluctuations due to meteorological conditions. The methodology developed is a useful tool for optimization and prediction of the performance of these systems.

  12. Performance analysis of InSb based QWFET for ultra high speed applications

    International Nuclear Information System (INIS)

    Subash, T. D.; Gnanasekaran, T.; Divya, C.

    2015-01-01

    An indium antimonide based QWFET (quantum well field effect transistor) with the gate length down to 50 nm has been designed and investigated for the first time for L-band radar applications at 230 GHz. QWFETs are designed at the high performance node of the International Technology Road Map for Semiconductors (ITRS) requirements of drive current (Semiconductor Industry Association 2010). The performance of the device is investigated using the SYNOPSYS CAD (TCAD) software. InSb based QWFET could be a promising device technology for very low power and ultra-high speed performance with 5–10 times low DC power dissipation. (semiconductor devices)

  13. Structure Design and Performance Analysis of High-Speed Miniature Ball Bearing

    Science.gov (United States)

    Li, Songsheng; Zhang, Guoye; Chen, Bin; Shen, Yuan

    2017-07-01

    The working performances of miniature ball bearings are obviously affected by its’ geometric structure parameters. In this paper, quasi-static analysis theory is applied in the design of miniature ball bearings. Firstly, it is studied the influence of geometry structure, preload and rotating speed on the dynamic performance of bearing. Secondly, bearing dynamic characteristics are analyzed which include the bearing stiffness and Spin to roll Ratio. Lastly, the contact stress and bearing life are calculated. The results indicate that structure parameters play an importance role in bearing’s dynamic performances. Miniature ball bearings which have lager ball number, bigger ball diameter and smaller inner race groove radius can get better performances while velocity and preload have great impact on the bearing life. So that parameters of miniature bearing should be chosen cautiously.

  14. Analysis of final products from the liquid alkanes radiolysis at low dose, low temperature and high dose rate

    International Nuclear Information System (INIS)

    Tilquin, B.; Doncker, J. de.

    1991-01-01

    Yields of final products (dimers) from the radiolysis of n-hexane and 2,3-dimethylbutane are studied by capillary chromatographic techniques for trace analysis. Reaction of intermediates with the products, the alkane molecules or impurities, is reduced by using low dose (1 kGy), low temperature (195 K) and high dose rate (LINAC). Temperature is the most important experiment variable; by reducing the temperature, reactions with significant activation energies do not compete with radical-radical termination reactions. Products from LINAC radiolysis provide information about active species (reactive fragment, allylic radical...) which deserve a more detailed examination by direct methods [fr

  15. Discrimination of Wild Paris Based on Near Infrared Spectroscopy and High Performance Liquid Chromatography Combined with Multivariate Analysis

    Science.gov (United States)

    Zhao, Yanli; Zhang, Ji; Yuan, Tianjun; Shen, Tao; Li, Wei; Yang, Shihua; Hou, Ying; Wang, Yuanzhong; Jin, Hang

    2014-01-01

    Different geographical origins and species of Paris obtained from southwestern China were discriminated by near infrared (NIR) spectroscopy and high performance liquid chromatography (HPLC) combined with multivariate analysis. The NIR parameter settings were scanning (64 times), resolution (4 cm−1), scanning range (10000 cm−1∼4000 cm−1) and parallel collection (3 times). NIR spectrum was optimized by TQ 8.6 software, and the ranges 7455∼6852 cm−1 and 5973∼4007 cm−1 were selected according to the spectrum standard deviation. The contents of polyphyllin I, polyphyllin II, polyphyllin VI, and polyphyllin VII and total steroid saponins were detected by HPLC. The contents of chemical components data matrix and spectrum data matrix were integrated and analyzed by partial least squares discriminant analysis (PLS-DA). From the PLS-DA model of NIR spectrum, Paris samples were separated into three groups according to the different geographical origins. The R2X and Q2Y described accumulative contribution rates were 99.50% and 94.03% of the total variance, respectively. The PLS-DA model according to 12 species of Paris described 99.62% of the variation in X and predicted 95.23% in Y. The results of the contents of chemical components described differences among collections quantitatively. A multivariate statistical model of PLS-DA showed geographical origins of Paris had a much greater influence on Paris compared with species. NIR and HPLC combined with multivariate analysis could discriminate different geographical origins and different species. The quality of Paris showed regional dependence. PMID:24558477

  16. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  17. BANK RATING. A COMPARATIVE ANALYSIS

    Directory of Open Access Journals (Sweden)

    Batrancea Ioan

    2015-07-01

    Full Text Available Banks in Romania offers its customers a wide range of products but which involves both risk taking. Therefore researchers seek to build rating models to help managers of banks to risk of non-recovery of loans and interest. In the following we highlight rating Raiffeisen Bank, BCR-ERSTE Bank and Transilvania Bank, based on the models CAAMPL and Stickney making a comparative analysis of the two rating models.

  18. libRoadRunner: a high performance SBML simulation and analysis library.

    Science.gov (United States)

    Somogyi, Endre T; Bouteiller, Jean-Marie; Glazier, James A; König, Matthias; Medley, J Kyle; Swat, Maciej H; Sauro, Herbert M

    2015-10-15

    This article presents libRoadRunner, an extensible, high-performance, cross-platform, open-source software library for the simulation and analysis of models expressed using Systems Biology Markup Language (SBML). SBML is the most widely used standard for representing dynamic networks, especially biochemical networks. libRoadRunner is fast enough to support large-scale problems such as tissue models, studies that require large numbers of repeated runs and interactive simulations. libRoadRunner is a self-contained library, able to run both as a component inside other tools via its C++ and C bindings, and interactively through its Python interface. Its Python Application Programming Interface (API) is similar to the APIs of MATLAB ( WWWMATHWORKSCOM: ) and SciPy ( HTTP//WWWSCIPYORG/: ), making it fast and easy to learn. libRoadRunner uses a custom Just-In-Time (JIT) compiler built on the widely used LLVM JIT compiler framework. It compiles SBML-specified models directly into native machine code for a variety of processors, making it appropriate for solving extremely large models or repeated runs. libRoadRunner is flexible, supporting the bulk of the SBML specification (except for delay and non-linear algebraic equations) including several SBML extensions (composition and distributions). It offers multiple deterministic and stochastic integrators, as well as tools for steady-state analysis, stability analysis and structural analysis of the stoichiometric matrix. libRoadRunner binary distributions are available for Mac OS X, Linux and Windows. The library is licensed under Apache License Version 2.0. libRoadRunner is also available for ARM-based computers such as the Raspberry Pi. http://www.libroadrunner.org provides online documentation, full build instructions, binaries and a git source repository. hsauro@u.washington.edu or somogyie@indiana.edu Supplementary data are available at Bioinformatics online. Published by Oxford University Press 2015. This work is written

  19. Spanish experience of fuel performance under zinc injection conditions in high duty plants

    International Nuclear Information System (INIS)

    Sanchez, Alicia; Doncel, Nuria

    2008-01-01

    Zinc is being added to the reactor coolant system in three Spanish PWRs (Vandellos II, Asco I and Asco II), owned by Association Nuclear Asco Vandellos AIE (ANAV), to delay Primary Water Stress Corrosion Cracking (PWSCC) initiation. Although additional advantages from zinc addition are expected, in the short term some concern exists concerning fuel performance during the first cycles of zinc addition due to a possible elevation of corrosion products from system materials when zinc is initially added. Elevated corrosion product levels in a high duty plant may cause an enhancement on crud deposited on fuel, increasing Axial Offset Anomaly (AOA) risk and accelerated cladding corrosion. To demonstrate the acceptable performance of ZIRLOTM clad fuel under zinc chemistry at a high duty plant, EPRI's Fuel Reliability Program (FRP) has chosen Vandellos II as a zinc demonstration plant to perform oxide thickness measurements and crud scraping and analysis. This paper presents the results from Vandellos II and Asco II oxide measurements as well as the conclusions from the crud samples analyses performed at Vandellos II. Furthermore, the effect of zinc addition on corrosion product behavior and dose rates are be discussed

  20. High-capacity neutron activation analysis facility

    International Nuclear Information System (INIS)

    Hochel, R.C.

    1979-01-01

    A high-capacity neutron activation analysis facility, the Reactor Activation Facility, was designed and built and has been in operation for about a year at one of the Savannah River Plant's production reactors. The facility determines uranium and about 19 other trace elements in hydrogeochemical samples collected in the National Uranium Resource Evaluation program. The facility has a demonstrated average analysis rate of over 10,000 samples per month, and a peak rate of over 16,000 samples per month. Uranium is determined by cyclic activation and delayed neutron counting of the U-235 fission products; other elements are determined from gamma-ray spectra recorded in subsequent irradiation, decay, and counting steps. The method relies on the absolute activation technique and is highly automated for round-the-clock unattended operation

  1. Data and analytics to inform energy retrofit of high performance buildings

    International Nuclear Information System (INIS)

    Hong, Tianzhen; Yang, Le; Hill, David; Feng, Wei

    2014-01-01

    Highlights: • High performance buildings can be retrofitted using measured data and analytics. • Data of energy use, systems operating and environmental conditions are needed. • An energy data model based on the ISO Standard 12655 is key for energy benchmarking. • Three types of analytics are used: energy profiling, benchmarking, and diagnostics. • The case study shows 20% of electricity can be saved by retrofit. - Abstract: Buildings consume more than one-third of the world’s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energy audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis – energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high

  2. Analysis of native human plasma proteins and haemoglobin for the presence of bityrosine by high-performance liquid chromatography

    DEFF Research Database (Denmark)

    Daneshvar, B; Frandsen, H; Dragsted, L O

    1997-01-01

    fluorescent substance, bityrosine. High-performance liquid chromatography (HPLC) analysis of acid hydrolyzed serum albumin after oxidation with peroxidase/H2O2 or with Cu++/H2O2 showed that bityrosine had been formed whereas oxidation of this protein with Fe(III)/ascorbate did not result in the formation...

  3. Wavelet and receiver operating characteristic analysis of heart rate variability

    Science.gov (United States)

    McCaffery, G.; Griffith, T. M.; Naka, K.; Frennaux, M. P.; Matthai, C. C.

    2002-02-01

    Multiresolution wavelet analysis has been used to study the heart rate variability in two classes of patients with different pathological conditions. The scale dependent measure of Thurner et al. was found to be statistically significant in discriminating patients suffering from hypercardiomyopathy from a control set of normal subjects. We have performed Receiver Operating Characteristc (ROC) analysis and found the ROC area to be a useful measure by which to label the significance of the discrimination, as well as to describe the severity of heart dysfunction.

  4. High School Graduation Rates:Alternative Methods and Implications

    Directory of Open Access Journals (Sweden)

    Jing Miao

    2004-10-01

    Full Text Available The No Child Left Behind Act has brought great attention to the high school graduation rate as one of the mandatory accountability measures for public school systems. However, there is no consensus on how to calculate the high school graduation rate given the lack of longitudinal databases that track individual students. This study reviews literature on and practices in reporting high school graduation rates, compares graduation rate estimates yielded from alternative methods, and estimates discrepancies between alternative results at national, state, and state ethnic group levels. Despite the graduation rate method used, results indicate that high school graduation rates in the U.S. have been declining in recent years and that graduation rates for black and Hispanic students lag substantially behind those of white students. As to graduation rate method preferred, this study found no evidence that the conceptually more complex methods yield more accurate or valid graduation rate estimates than the simpler methods.

  5. High-rate lithium thionyl-chloride battery development

    Energy Technology Data Exchange (ETDEWEB)

    Cieslak, W.R.; Weigand, D.E.

    1993-12-31

    We have developed a lithium thionyl-chloride cell for use in a high rate battery application to provide power for a missile computer and stage separation detonators. The battery pack contains 20 high surface area ``DD`` cells wired in a series-parallel configuration to supply a nominal 28 volts with a continuous draw of 20 amperes. The load profile also requires six squib firing pulses of one second duration at a 20 ampere peak. Performance and safety of the cells were optimized in a ``D`` cell configuration before progressing to the longer ``DD` cell. Active surface area in the ``D`` cell is 735 cm{sup 2}, and 1650 cm{sup 2} in the ``DD`` cell. The design includes 1.5M LiAlCl{sub 4}/SOCl{sub 2} electrolyte, a cathode blend of Shawinigan Acetylene Black and Cabot Black Pearls 2000 carbons, Scimat ETFE separator, and photoetched current collectors.

  6. Time motion and video analysis of classical ballet and contemporary dance performance.

    Science.gov (United States)

    Wyon, M A; Twitchett, E; Angioi, M; Clarke, F; Metsios, G; Koutedakis, Y

    2011-11-01

    Video analysis has become a useful tool in the preparation for sport performance and its use has highlighted the different physiological demands of seemingly similar sports and playing positions. The aim of the current study was to examine the performance differences between classical ballet and contemporary dance. In total 93 dance performances (48 ballet and 45 contemporary) were analysed for exercise intensity, changes in direction and specific discrete skills (e. g., jumps, lifts). Results revealed significant differences between the 2 dance forms for exercise intensity (pBallet was characterised by longer periods at rest (38 s x min(-1)) and high to very high exercise intensities (9 s x min(-1)), whilst contemporary dance featured more continuous moderate exercise intensities (27 s x min(-1)). These differences have implications on the energy systems utilised during performance with ballet potentially stressing the anaerobic system more than contemporary dance. The observed high rates in the discrete skills in ballet (5 jumps x min(-1); 2 lifts x min(-1)) can cause local muscular damage, particularly in relatively weaker individuals. In conclusion, classical ballet and contemporary dance performances are as significantly different in the underlying physical demands placed on their performers as the artistic aspects of the choreography. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Intra-system reliability of SICS: video-tracking system (Digital.Stadium®) for performance analysis in football.

    Science.gov (United States)

    Beato, Marco; Jamil, Mikael

    2017-05-09

    The correct evaluation of external load parameters is a key factor in professional football. The instrumentations usually utilised to quantify the external load parameters during official matches are Video-Tracking Systems (VTS). VTS is a technology that records two- dimensional position data (x and y) at high sampling rates (over 25 Hz). The aim of this study was to evaluate the intra-system reliability of Digital.Stadium® VTS. 28 professional male football players taking part in the Italian Serie A (age 24 ± 6 years, body mass 79.5 ± 7.8 kg, stature 1.83 ± 0.05 m) during the 2015/16 season were enrolled in this study (Team A and Team B). Video-analysis was done during an official match and data analysis was performed immediately after the game ended and then replicated a week later. This study reported a near perfect relationship between the initial analysis (analysis 1) and the replicated analysis undertaken a week later (analysis 2). R2 coefficients were highly significant for each of the performance parameters, p power of 9.65 ± 1.64 w kg-1 and 9.58 ± 1.61 w kg-1, in analysis 1 and analysis 2, respectively. The findings reported in this study underlined that all data reported by Digital.Stadium® VTS showed high levels of absolute and relative reliability.

  8. Heat affected zone and fatigue crack propagation behavior of high performance steel

    International Nuclear Information System (INIS)

    Choi, Sung Won; Kang, Dong Hwan; Kim, Tae Won; Lee, Jong Kwan

    2009-01-01

    The effect of heat affected zone in high performance steel on fatigue crack propagation behavior, which is related to the subsequent microstructure, was investigated. A modified Paris-Erdogan equation was presented for the analysis of fatigue crack propagation behavior corresponding to the heat affected zone conditions. Fatigue crack propagation tests under 0.3 stress ratio and 0.1 load frequency were conducted for both finegrained and coarse-grained heat affected zones, respectively. As shown in the results, much higher crack growth rate occurred in a relatively larger mean grain size material under the same stress intensity range of fatigue crack propagation process for the material.

  9. Application of high-frame-rate neutron radiography to fluid measurement

    International Nuclear Information System (INIS)

    Mishima, Kaichiro; Hibiki, Takashi

    1997-01-01

    To apply Neutron radiography (NR) technique to multiphase flow research, high frame-rate NR was developed by assembling up-to-date technologies for neutron source, scintillator, high-speed video and image intensifier. This imaging system has several advantages such as a long recording time (up to 21 minutes), high-frame-rate (up to 1000 frames/s) imaging and no need for triggering signal. Visualization studies of air-water two-phase flow in a metallic duct and molten metal-water interaction were performed at the recording speeds of 250, 500 and 1000 frames/s. The qualities of those consecutive images were good enough to observe the flow pattern and behavior. It was demonstrated also that some characteristics of two-phase flow could be measured from those images in collaboration with image processing techniques. By utilizing geometrical information extracted from NR images, data on flow regime, rising velocity of bubbles, and wave height and interfacial area in annular flow could be obtained. By utilizing attenuation characteristics of neutrons in materials, measurements of void profile and average void fraction could be performed. For this purpose, a quantification method, i.e. Σ-scaling method, was proposed based upon the consideration on the effect of scattered neutrons. This method was tested against known void profiles and compared with existing measurement methods and a correlation for void fraction. It was confirmed that this new technique has significant advantages both in visualizing and measuring high-speed fluid phenomena. (J.P.N.)

  10. Low Cost Metal Carbide Nanocrystals as Binding and Electrocatalytic Sites for High Performance Li-S Batteries.

    Science.gov (United States)

    Zhou, Fei; Li, Zheng; Luo, Xuan; Wu, Tong; Jiang, Bin; Lu, Lei-Lei; Yao, Hong-Bin; Antonietti, Markus; Yu, Shu-Hong

    2018-02-14

    Lithium sulfur (Li-S) batteries are considered as promising energy storage systems for the next generation of batteries due to their high theoretical energy densities and low cost. Much effort has been made to improve the practical energy densities and cycling stability of Li-S batteries via diverse designs of materials nanostructure. However, achieving simultaneously good rate capabilities and stable cycling of Li-S batteries is still challenging. Herein, we propose a strategy to utilize a dual effect of metal carbide nanoparticles decorated on carbon nanofibers (MC NPs-CNFs) to realize high rate performance, low hysteresis, and long cycling stability of Li-S batteries in one system. The adsorption experiments of lithium polysulfides (LiPS) to MC NPs and corresponding theoretical calculations demonstrate that LiPS are likely to be adsorbed and diffused on the surface of MC NPs because of their moderate chemical bonding. MC NPs turn out to have also an electrocatalytic role and accelerate electrochemical redox reactions of LiPS, as proven by cyclic voltammetry analysis. The fabricated Li-S batteries based on the W 2 C NPs-CNFs hybrid electrodes display not only high specific capacity of 1200 mAh/g at 0.2C but also excellent rate performance and cycling stability, for example, a model setup can be operated at 1C for 500 cycles maintaining a final specific capacity of 605 mAh/g with a degradation rate as low as 0.06%/cycle.

  11. Improving the singles rate method for modeling accidental coincidences in high-resolution PET

    International Nuclear Information System (INIS)

    Oliver, Josep F; Rafecas, Magdalena

    2010-01-01

    Random coincidences ('randoms') are one of the main sources of image degradation in PET imaging. In order to correct for this effect, an accurate method to estimate the contribution of random events is necessary. This aspect becomes especially relevant for high-resolution PET scanners where the highest image quality is sought and accurate quantitative analysis is undertaken. One common approach to estimate randoms is the so-called singles rate method (SR) widely used because of its good statistical properties. SR is based on the measurement of the singles rate in each detector element. However, recent studies suggest that SR systematically overestimates the correct random rate. This overestimation can be particularly marked for low energy thresholds, below 250 keV used in some applications and could entail a significant image degradation. In this work, we investigate the performance of SR as a function of the activity, geometry of the source and energy acceptance window used. We also investigate the performance of an alternative method, which we call 'singles trues' (ST) that improves SR by properly modeling the presence of true coincidences in the sample. Nevertheless, in any real data acquisition the knowledge of which singles are members of a true coincidence is lost. Therefore, we propose an iterative method, STi, that provides an estimation based on ST but which only requires the knowledge of measurable quantities: prompts and singles. Due to inter-crystal scatter, for wide energy windows ST only partially corrects SR overestimations. While SR deviations are in the range 86-300% (depending on the source geometry), the ST deviations are systematically smaller and contained in the range 4-60%. STi fails to reproduce the ST results, although for not too high activities the deviation with respect to ST is only a few percent. For conventional energy windows, i.e. those without inter-crystal scatter, the ST method corrects the SR overestimations, and deviations from

  12. Malignancy rates and diagnostic performance of the Bosniak classification for the diagnosis of cystic renal lesions in computed tomography - a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sevcenco, Sabina; Shariat, Shahrokh F. [Medical University of Vienna, Department of Urology, Vienna (Austria); Spick, Claudio; Helbich, Thomas H.; Baltzer, Pascal A. [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, General Hospital Vienna, Vienna (Austria); Heinz, Gertraud [University Hospital of Sankt-Poelten, Department of Radiology, Poelten (Austria); Klingler, Hans C. [Wilhelminenspital, Department of Urology, Vienna (Austria); Rauchenwald, Michael [Donauspital, Department of Urology, Vienna (Austria)

    2017-06-15

    To systematically review the literature on the Bosniak classification system in CT to determine its diagnostic performance to diagnose malignant cystic lesions and the prevalence of malignancy in Bosniak categories. A predefined database search was performed from 1 January 1986 to 18 January 2016. Two independent reviewers extracted data on malignancy rates in Bosniak categories and several covariates using predefined criteria. Study quality was assessed using QUADAS-2. Meta-analysis included data pooling, subgroup analyses, meta-regression and investigation of publication bias. A total of 35 studies, which included 2,578 lesions, were investigated. Data on observer experience, inter-observer variation and technical CT standards were insufficiently reported. The pooled rate of malignancy increased from Bosniak I (3.2 %, 95 % CI 0-6.8, I{sup 2} = 5 %) to Bosniak II (6 %, 95 % CI 2.7-9.3, I{sup 2} = 32 %), IIF (6.7 %, 95 % CI 5-8.4, I{sup 2} = 0 %), III (55.1 %, 95 % CI 45.7-64.5, I{sup 2} = 89 %) and IV (91 %, 95 % CI 87.7-94.2, I{sup 2} = 36). Several study design-related influences on malignancy rates and subsequent diagnostic performance indices were identified. The Bosniak classification is an accurate tool with which to stratify the risk of malignancy in renal cystic lesions. (orig.)

  13. Leaky Vaccines Protect Highly Exposed Recipients at a Lower Rate: Implications for Vaccine Efficacy Estimation and Sieve Analysis

    Directory of Open Access Journals (Sweden)

    Paul T. Edlefsen

    2014-01-01

    Full Text Available “Leaky” vaccines are those for which vaccine-induced protection reduces infection rates on a per-exposure basis, as opposed to “all-or-none” vaccines, which reduce infection rates to zero for some fraction of subjects, independent of the number of exposures. Leaky vaccines therefore protect subjects with fewer exposures at a higher effective rate than subjects with more exposures. This simple observation has serious implications for analysis methodologies that rely on the assumption that the vaccine effect is homogeneous across subjects. We argue and show through examples that this heterogeneous vaccine effect leads to a violation of the proportional hazards assumption, to incomparability of infected cases across treatment groups, and to nonindependence of the distributions of the competing failure processes in a competing risks setting. We discuss implications for vaccine efficacy estimation, correlates of protection analysis, and mark-specific efficacy analysis (also known as sieve analysis.

  14. Leaky vaccines protect highly exposed recipients at a lower rate: implications for vaccine efficacy estimation and sieve analysis.

    Science.gov (United States)

    Edlefsen, Paul T

    2014-01-01

    "Leaky" vaccines are those for which vaccine-induced protection reduces infection rates on a per-exposure basis, as opposed to "all-or-none" vaccines, which reduce infection rates to zero for some fraction of subjects, independent of the number of exposures. Leaky vaccines therefore protect subjects with fewer exposures at a higher effective rate than subjects with more exposures. This simple observation has serious implications for analysis methodologies that rely on the assumption that the vaccine effect is homogeneous across subjects. We argue and show through examples that this heterogeneous vaccine effect leads to a violation of the proportional hazards assumption, to incomparability of infected cases across treatment groups, and to nonindependence of the distributions of the competing failure processes in a competing risks setting. We discuss implications for vaccine efficacy estimation, correlates of protection analysis, and mark-specific efficacy analysis (also known as sieve analysis).

  15. The NCI High Performance Computing (HPC) and High Performance Data (HPD) Platform to Support the Analysis of Petascale Environmental Data Collections

    Science.gov (United States)

    Evans, B. J. K.; Pugh, T.; Wyborn, L. A.; Porter, D.; Allen, C.; Smillie, J.; Antony, J.; Trenham, C.; Evans, B. J.; Beckett, D.; Erwin, T.; King, E.; Hodge, J.; Woodcock, R.; Fraser, R.; Lescinsky, D. T.

    2014-12-01

    The National Computational Infrastructure (NCI) has co-located a priority set of national data assets within a HPC research platform. This powerful in-situ computational platform has been created to help serve and analyse the massive amounts of data across the spectrum of environmental collections - in particular the climate, observational data and geoscientific domains. This paper examines the infrastructure, innovation and opportunity for this significant research platform. NCI currently manages nationally significant data collections (10+ PB) categorised as 1) earth system sciences, climate and weather model data assets and products, 2) earth and marine observations and products, 3) geosciences, 4) terrestrial ecosystem, 5) water management and hydrology, and 6) astronomy, social science and biosciences. The data is largely sourced from the NCI partners (who include the custodians of many of the national scientific records), major research communities, and collaborating overseas organisations. By co-locating these large valuable data assets, new opportunities have arisen by harmonising the data collections, making a powerful transdisciplinary research platformThe data is accessible within an integrated HPC-HPD environment - a 1.2 PFlop supercomputer (Raijin), a HPC class 3000 core OpenStack cloud system and several highly connected large scale and high-bandwidth Lustre filesystems. New scientific software, cloud-scale techniques, server-side visualisation and data services have been harnessed and integrated into the platform, so that analysis is performed seamlessly across the traditional boundaries of the underlying data domains. Characterisation of the techniques along with performance profiling ensures scalability of each software component, all of which can either be enhanced or replaced through future improvements. A Development-to-Operations (DevOps) framework has also been implemented to manage the scale of the software complexity alone. This ensures that

  16. Aqueous Corrosion Rates for Waste Package Materials

    Energy Technology Data Exchange (ETDEWEB)

    S. Arthur

    2004-10-08

    The purpose of this analysis, as directed by ''Technical Work Plan for: Regulatory Integration Modeling and Analysis of the Waste Form and Waste Package'' (BSC 2004 [DIRS 171583]), is to compile applicable corrosion data from the literature (journal articles, engineering documents, materials handbooks, or standards, and national laboratory reports), evaluate the quality of these data, and use these to perform statistical analyses and distributions for aqueous corrosion rates of waste package materials. The purpose of this report is not to describe the performance of engineered barriers for the TSPA-LA. Instead, the analysis provides simple statistics on aqueous corrosion rates of steels and alloys. These rates are limited by various aqueous parameters such as temperature (up to 100 C), water type (i.e., fresh versus saline), and pH. Corrosion data of materials at pH extremes (below 4 and above 9) are not included in this analysis, as materials commonly display different corrosion behaviors under these conditions. The exception is highly corrosion-resistant materials (Inconel Alloys) for which rate data from corrosion tests at a pH of approximately 3 were included. The waste package materials investigated are those from the long and short 5-DHLW waste packages, 2-MCO/2-DHLW waste package, and the 21-PWR commercial waste package. This analysis also contains rate data for some of the materials present inside the fuel canisters for the following fuel types: U-Mo (Fermi U-10%Mo), MOX (FFTF), Thorium Carbide and Th/U Carbide (Fort Saint Vrain [FSVR]), Th/U Oxide (Shippingport LWBR), U-metal (N Reactor), Intact U-Oxide (Shippingport PWR, Commercial), aluminum-based, and U-Zr-H (TRIGA). Analysis of corrosion rates for Alloy 22, spent nuclear fuel, defense high level waste (DHLW) glass, and Titanium Grade 7 can be found in other analysis or model reports.

  17. Aqueous Corrosion Rates for Waste Package Materials

    International Nuclear Information System (INIS)

    Arthur, S.

    2004-01-01

    The purpose of this analysis, as directed by ''Technical Work Plan for: Regulatory Integration Modeling and Analysis of the Waste Form and Waste Package'' (BSC 2004 [DIRS 171583]), is to compile applicable corrosion data from the literature (journal articles, engineering documents, materials handbooks, or standards, and national laboratory reports), evaluate the quality of these data, and use these to perform statistical analyses and distributions for aqueous corrosion rates of waste package materials. The purpose of this report is not to describe the performance of engineered barriers for the TSPA-LA. Instead, the analysis provides simple statistics on aqueous corrosion rates of steels and alloys. These rates are limited by various aqueous parameters such as temperature (up to 100 C), water type (i.e., fresh versus saline), and pH. Corrosion data of materials at pH extremes (below 4 and above 9) are not included in this analysis, as materials commonly display different corrosion behaviors under these conditions. The exception is highly corrosion-resistant materials (Inconel Alloys) for which rate data from corrosion tests at a pH of approximately 3 were included. The waste package materials investigated are those from the long and short 5-DHLW waste packages, 2-MCO/2-DHLW waste package, and the 21-PWR commercial waste package. This analysis also contains rate data for some of the materials present inside the fuel canisters for the following fuel types: U-Mo (Fermi U-10%Mo), MOX (FFTF), Thorium Carbide and Th/U Carbide (Fort Saint Vrain [FSVR]), Th/U Oxide (Shippingport LWBR), U-metal (N Reactor), Intact U-Oxide (Shippingport PWR, Commercial), aluminum-based, and U-Zr-H (TRIGA). Analysis of corrosion rates for Alloy 22, spent nuclear fuel, defense high level waste (DHLW) glass, and Titanium Grade 7 can be found in other analysis or model reports

  18. Targeting high-performance liquid chromatography-high-resolution mass spectrometry-solid-phase extraction-nuclear magnetic resonance analysis with high-resolution radical scavenging profiles - bioactive secondary metabolites from the endophytic fungus Penicillium namyslowskii

    DEFF Research Database (Denmark)

    Wubshet, Sileshi Gizachew; Nyberg, Nils; Tejesvi, Mysore V.

    2013-01-01

    The high-resolution radical scavenging profile of an extract of the endophytic fungus Penicillium namyslowskii was used to target analysis by high-performance liquid chromatography-high-resolution mass spectrometry-solid-phase extraction-nuclear magnetic resonance spectroscopy, i.e., HPLC...... NMR probe designed for 1.7-mm NMR tubes. To further explore the potential of the above HPLC-HRMS-SPE-NMR platform for analysis of endophytic extracts, six peaks displaying no radical scavenging activity were also analyzed. This allowed unambiguous identification of six metabolites, i...... and griseofulvin, directly from crude extract via HPLC-HRMS-SPE-NMR. Dechlorodehydrogriseofulvin was reported for the first time from nature....

  19. Novel driver method to improve ordinary CCD frame rate for high-speed imaging diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Tong-Ding, E-mail: snuohui@126.com; Li, Bin-Kang; Yang, Shao-Hua; Guo, Ming-An; Yan, Ming

    2016-06-21

    The use of ordinary Charge-coupled-Device (CCD) imagers for the analysis of fast physical phenomenon is restricted because of the low-speed performance resulting from their long output times. Even though the form of Intensified-CCD (ICCD), coupled with a gated image intensifier, has extended their use for high speed imaging, the deficiency remains to be solved that ICDD could record only one image in a single shot. This paper presents a novel driver method designed to significantly improve the ordinary interline CCD burst frame rate for high-speed photography. This method is based on the use of vertical registers as storage, so that a small number of additional frames comprised of reduced-spatial-resolution images obtained via a specific sampling operation can be buffered. Hence, the interval time of the received series of images is related to the exposure and vertical transfer times only and, thus, the burst frame rate can be increased significantly. A prototype camera based on this method is designed as part of this study, exhibiting a burst rate of up to 250,000 frames per second (fps) and a capacity to record three continuous images. This device exhibits a speed enhancement of approximately 16,000 times compared with the conventional speed, with a spatial resolution reduction of only 1/4.

  20. Large inelastic deformation analysis of steel pressure vessels at high temperature

    International Nuclear Information System (INIS)

    Ikonen, K.

    2001-01-01

    This publication describes the calculation methodology developed for a large inelastic deformation analysis of pressure vessels at high temperature. Continuum mechanical formulation related to a large deformation analysis is presented. Application of the constitutive equations is simplified when the evolution of stress and deformation state of an infinitesimal material element is considered in the directions of principal strains determined by the deformation during a finite time increment. A quantitative modelling of time dependent inelastic deformation is applied for reactor pressure vessel steels. Experimental data of uniaxial tensile, relaxation and creep tests performed at different laboratories for reactor pressure vessel steels are investigated and processed. An inelastic deformation rate model of strain hardening type is adopted. The model simulates well the axial tensile, relaxation and creep tests from room temperature to high temperature with only a few fitting parameters. The measurement data refined for the inelastic deformation rate model show useful information about inelastic deformation phenomena of reactor pressure vessel steels over a wide temperature range. The methodology and calculation process are validated by comparing the calculated results with measurements from experiments on small scale pressure vessels. A reasonably good agreement, when taking several uncertainties into account, is obtained between the measured and calculated results concerning deformation rate and failure location. (orig.)

  1. Split-Hopkinson Pressure Bar: an experimental technique for high strain rate tests

    International Nuclear Information System (INIS)

    Sharma, S.; Chavan, V.M.; Agrawal, R.G.; Patel, R.J.; Kapoor, R.; Chakravartty, J.K.

    2011-06-01

    Mechanical properties of materials are, in general, strain rate dependent, i.e. they respond differently at quasi-static and higher strain rate condition. The Split-Hopkinson Pressure Bar (SHPB), also referred to as Kolsky bar is a commonly used setup for high strain rate testing. SHPB is suitable for high strain rate test in strain rate range of 10 2 to 10 4 s -1 . These high strain rate data are required for safety and structural integrity assessment of structures subjected to dynamic loading. As high strain rate data are not easily available in open literature need was felt for setting up such high strain rate testing machine. SHPB at BARC was designed and set-up inhouse jointly by Refuelling Technology Division and Mechanical Metallurgy Division, at Hall no. 3, BARC. A number of conceptual designs for SHPB were thought of and the optimized design was worked out. The challenges of precision tolerance, straightness in bars and design and proper functioning of pneumatic gun were met. This setup has been used extensively to study the high strain rate material behavior. This report introduces the SHPB in general and the setup at BARC in particular. The history of development of SHPB, the basic formulations of one dimensional wave propagation, the relations between the wave velocity, particle velocity and elastic strain in a one dimensional bar, and the equations used to obtain the final stress vs. strain curves are described. The calibration of the present setup, the pre-test calculations and the posttest analysis of data are described. Finally some of the experimental results on different materials such as Cu, SS305, SA516 and Zr, at room temperature and elevated temperatures are presented. (author)

  2. Leveraging the Power of High Performance Computing for Next Generation Sequencing Data Analysis: Tricks and Twists from a High Throughput Exome Workflow

    Science.gov (United States)

    Wonczak, Stephan; Thiele, Holger; Nieroda, Lech; Jabbari, Kamel; Borowski, Stefan; Sinha, Vishal; Gunia, Wilfried; Lang, Ulrich; Achter, Viktor; Nürnberg, Peter

    2015-01-01

    Next generation sequencing (NGS) has been a great success and is now a standard method of research in the life sciences. With this technology, dozens of whole genomes or hundreds of exomes can be sequenced in rather short time, producing huge amounts of data. Complex bioinformatics analyses are required to turn these data into scientific findings. In order to run these analyses fast, automated workflows implemented on high performance computers are state of the art. While providing sufficient compute power and storage to meet the NGS data challenge, high performance computing (HPC) systems require special care when utilized for high throughput processing. This is especially true if the HPC system is shared by different users. Here, stability, robustness and maintainability are as important for automated workflows as speed and throughput. To achieve all of these aims, dedicated solutions have to be developed. In this paper, we present the tricks and twists that we utilized in the implementation of our exome data processing workflow. It may serve as a guideline for other high throughput data analysis projects using a similar infrastructure. The code implementing our solutions is provided in the supporting information files. PMID:25942438

  3. High temperature performance limit of containment system of transport cask

    International Nuclear Information System (INIS)

    Kato, Osamu; Saegusa, Toshiari

    1998-01-01

    The containment performance of a containment system using elastomer gaskets for transport casks under a high temperature and high pressure was clarified. Major results are as follows; (1) The deformation characteristics of the gaskets were represented by the compressive permanent strain rate (Dp). The temperature and time dependence was shown by Larson-Miller Parameter (LMP). (2) Generally, the high temperature performance limit is obtained by a value of LMP when the Dp value reaches 80%. However, the gaskets (FKM, VMQ, EPDM) used for real transport casks were not damaged and the containment performance was not deteriorated as a conservative condition. (3) Assuming that the service period of the gaskets for transport casks is 3 months or 1 year, the high temperature performance limit of the gasket made of fluorine rubber (FKM) is 202degC or 182degC, respectively, which includes safety margin. (author)

  4. STUDY REGARDING THE DETERMINATION OF THE FINANCIAL PERFORMANCE OF A COMPANY THROUGH MARKET RATES

    Directory of Open Access Journals (Sweden)

    Nicolae Baltes

    2015-11-01

    Full Text Available Determining the financial performance of an enterprise is necessary when making the decision to invest, which represents the proper selection of securities and the appropriate moment to enter on the market, meaning the time to purchase the securities. The study’s objective is to define, determinate and interpret the market rates, that are used in financial analysis in order to measure the company’s performance. The study, conducted on a Romanian company listed on the Bucharest Stock Exchange, leads to the conclusion that because of the financial crisis, the company’s financial performance was significantly affected.

  5. High School Graduation Rates:Alternative Methods and Implications

    OpenAIRE

    Jing Miao; Walt Haney

    2004-01-01

    The No Child Left Behind Act has brought great attention to the high school graduation rate as one of the mandatory accountability measures for public school systems. However, there is no consensus on how to calculate the high school graduation rate given the lack of longitudinal databases that track individual students. This study reviews literature on and practices in reporting high school graduation rates, compares graduation rate estimates yielded from alternative methods, and estimates d...

  6. Coal-fired high performance power generating system. Quarterly progress report, July 1, 1993--September 30, 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-12-31

    This report covers work carried out under Task 3, Preliminary Research and Development, and Task 4, Commercial Generating Plant Design, under contract DE-AC22-92PC91155, {open_quotes}Engineering Development of a Coal Fired High Performance Power Generation System{close_quotes} between DOE Pittsburgh Energy Technology Center and United Technologies Research Center. The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of >47% thermal efficiency; NO{sub x}, SO{sub x}, and particulates {le} 25% NSPS; cost {ge} 65% of heat input; and all solid wastes benign. The report discusses progress in cycle analysis, chemical reactor modeling, ash deposition rate calculations for HITAF (high temperature advanced furnace) convective air heater, air heater materials, and deposit initiation and growth on ceramic substrates.

  7. Performance of Novel Randomly Oriented High Graphene Carbon in Lithium Ion Capacitors

    Directory of Open Access Journals (Sweden)

    Rahul S. Kadam

    2018-01-01

    Full Text Available The structure of carbon material comprising the anode is the key to the performance of a lithium ion capacitor. In addition to determining the capacity, the structure of the carbon material also determines the diffusion rate of the lithium ion into the anode which in turn controls power density which is vital in high rate applications. This paper covers details of systematic investigation of the performance of a structurally novel carbon, called Randomly Oriented High Graphene (ROHG carbon, and graphite in a high rate application device, that is, lithium ion capacitor. Electrochemical impedance spectroscopy shows that ROHG is less resistive and has faster lithium ion diffusion rates (393.7 × 10−3 S·s(1/2 compared to graphite (338.1 × 10−3 S·s(1/2. The impedance spectroscopy data is supported by the cell data showing that the ROHG carbon based device has energy density of 22.8 Wh/l with a power density of 4349.3 W/l, whereas baseline graphite based device has energy density of 5 Wh/l and power density of 4243.3 W/l. This data clearly shows advantage of the randomly oriented graphene platelet structure of ROHG in lithium ion capacitor performance.

  8. The Effect of Sex on Heart Rate Variability at High Altitude.

    Science.gov (United States)

    Boos, Christopher John; Vincent, Emma; Mellor, Adrian; O'Hara, John; Newman, Caroline; Cruttenden, Richard; Scott, Phylip; Cooke, Mark; Matu, Jamie; Woods, David Richard

    2017-12-01

    There is evidence suggesting that high altitude (HA) exposure leads to a fall in heart rate variability (HRV) that is linked to the development of acute mountain sickness (AMS). The effects of sex on changes in HRV at HA and its relationship to AMS are unknown. HRV (5-min single-lead ECG) was measured in 63 healthy adults (41 men and 22 women) 18-56 yr of age at sea level (SL) and during a HA trek at 3619, 4600, and 5140 m, respectively. The main effects of altitude (SL, 3619 m, 4600 m, and 5140 m) and sex (men vs women) and their potential interaction were assessed using a factorial repeated-measures ANOVA. Logistic regression analyses were performed to assess the ability of HRV to predict AMS. Men and women were of similar age (31.2 ± 9.3 vs 31.7 ± 7.5 yr), ethnicity, and body and mass index. There was main effect for altitude on heart rate, SD of normal-to-normal (NN) intervals (SDNN), root mean square of successive differences (RMSSD), number of pairs of successive NN differing by >50 ms (NN50), NN50/total number of NN, very low-frequency power, low-frequency (LF) power, high-frequency (HF) power, and total power (TP). The most consistent effect on post hoc analysis was reduction in these HRV measures between 3619 and 5140 m at HA. Heart rate was significantly lower and SDNN, RMSSD, LF power, HF power, and TP were higher in men compared with women at HA. There was no interaction between sex and altitude for any of the HRV indices measured. HRV was not predictive of AMS development. Increasing HA leads to a reduction in HRV. Significant differences between men and women emerge at HA. HRV was not predictive of AMS.

  9. [Qualitative and quantitative analysis of amygdalin and its metabolite prunasin in plasma by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry].

    Science.gov (United States)

    Gao, Meng; Wang, Yuesheng; Wei, Huizhen; Ouyang, Hui; He, Mingzhen; Zeng, Lianqing; Shen, Fengyun; Guo, Qiang; Rao, Yi

    2014-06-01

    A method was developed for the determination of amygdalin and its metabolite prunasin in rat plasma after intragastric administration of Maxing shigan decoction. The analytes were identified by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the qualitative analysis of amygdalin and prunasin in the plasma sample was performed on a Shim-pack XR-ODS III HPLC column (75 mm x 2.0 mm, 1.6 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on a Triple TOF 5600 quadrupole time of flight mass spectrometer. The quantitative analysis of amygdalin and prunasin in the plasma sample was performed by separation on an Agilent C18 HPLC column (50 mm x 2.1 mm, 1.7 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on an AB Q-TRAP 4500 triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The qualitative analysis results showed that amygdalin and its metabolite prunasin were detected in the plasma sample. The quantitative analysis results showed that the linear range of amygdalin was 1.05-4 200 ng/mL with the correlation coefficient of 0.999 0 and the linear range of prunasin was 1.25-2 490 ng/mL with the correlation coefficient of 0.997 0. The method had a good precision with the relative standard deviations (RSDs) lower than 9.20% and the overall recoveries varied from 82.33% to 95.25%. The limits of detection (LODs) of amygdalin and prunasin were 0.50 ng/mL. With good reproducibility, the method is simple, fast and effective for the qualitative and quantitative analysis of the amygdalin and prunasin in plasma sample of rats which were administered by Maxing shigan decoction.

  10. Error-rate performance analysis of cooperative OFDMA system with decode-and-forward relaying

    KAUST Repository

    Fareed, Muhammad Mehboob; Uysal, Murat; Tsiftsis, Theodoros A.

    2014-01-01

    In this paper, we investigate the performance of a cooperative orthogonal frequency-division multiple-access (OFDMA) system with decode-and-forward (DaF) relaying. Specifically, we derive a closed-form approximate symbol-error-rate expression and analyze the achievable diversity orders. Depending on the relay location, a diversity order up to (LSkD + 1) + σ M m = 1 min(LSkRm + 1, LR mD + 1) is available, where M is the number of relays, and LS kD + 1, LSkRm + 1, and LRmD + 1 are the lengths of channel impulse responses of source-to-destination, source-to- mth relay, and mth relay-to-destination links, respectively. Monte Carlo simulation results are also presented to confirm the analytical findings. © 2013 IEEE.

  11. Error-rate performance analysis of cooperative OFDMA system with decode-and-forward relaying

    KAUST Repository

    Fareed, Muhammad Mehboob

    2014-06-01

    In this paper, we investigate the performance of a cooperative orthogonal frequency-division multiple-access (OFDMA) system with decode-and-forward (DaF) relaying. Specifically, we derive a closed-form approximate symbol-error-rate expression and analyze the achievable diversity orders. Depending on the relay location, a diversity order up to (LSkD + 1) + σ M m = 1 min(LSkRm + 1, LR mD + 1) is available, where M is the number of relays, and LS kD + 1, LSkRm + 1, and LRmD + 1 are the lengths of channel impulse responses of source-to-destination, source-to- mth relay, and mth relay-to-destination links, respectively. Monte Carlo simulation results are also presented to confirm the analytical findings. © 2013 IEEE.

  12. Relationship between Self-Rated Health and Lifestyle and Food Habits in Japanese High School Students

    Directory of Open Access Journals (Sweden)

    Tomoko Osera

    2017-10-01

    Full Text Available Self-rated health (SRH, a subjective assessment of health status, is extensively used in the field of public health. It is an important and valid measure that is strongly related to morbidity, mortality, longevity and health status. Adolescence is a crucial period for the formation of health status, because health-risk behaviours (e.g., skipping breakfast are often established during this period. In this study, we investigated the relationship of SRH with lifestyle and eating habits in Japanese high school students. In this study, 1296 students aged 16–18 years from 11 high schools in Japan participated. A questionnaire was administered to these participants that included a question on SRH, five questions on demographic characteristics, six questions on lifestyle items (e.g., wake-up time, five questions on miscellaneous health issues (e.g., anorexia, and 25 questions on food habits and attitudes towards food. We examined the differences between self-rated healthy and unhealthy groups using logistic regression analysis adjusted for gender and age. A dichotomy regression analysis was performed using a stepwise elimination method. Of the 1296 respondents, 16.7% reported feeling unhealthy, 57.7% of whom were females. The self-rated healthy group had a higher frequency of eating breakfast (odds ratio (OR: 2.13; confidence interval (CI: 1.07–4.24 and liked home meals to a greater extent (OR: 3.12; CI: 1.27–7.65 than the self-rated unhealthy group. The two groups did not differ significantly in terms of other lifestyle factors or unidentified complaints. Our results suggest that liking home meals during adolescence may lead to the development of good eating habits, i.e., eating breakfast, and better SRH.

  13. THE ANALYSIS OF NON PERFORMING FINANCING (NPF DETERMINANTS ON INDONESIAN ISLAMIC BANKING (PERIOD FROM JANUARY 2003 - MARCH 2013

    Directory of Open Access Journals (Sweden)

    Mohammad Nasih

    2013-07-01

    Full Text Available This project presents a summary of analysis on the factors affecting Non Performing Financing (NPF of Sharia banking in Indonesia, namely Economic Performance (EK, Total Financing (FIN, Finance Rate (FR, Dummy Global Financial Crisis (D07 and Inflation Rate (INF.The method employed was Cointegration Test where the data used derived from January 2003 to March 2013 monthly data. The statistical analysis results showed that each of independent variables significantly influence the growth of NPF (non-performing financing of Sharia banking in Indonesia. Additionally, the study gave the implication that Islamic banking should apply prevention methods and prudence principles appropriately in providing finance to clients in order to avoid high NPF in Islamic banking. Afterward, the Government, as the highest authority of banking institution, was expected to support the sharia banking financing by establishing an independent agency to help the bank assessing the feasibility of the proposed candidates who would receive financing assistance from sharia banking

  14. Significant improvement in performances of LiNi0.5Mn1.5O4 through surface modification with high ordered Al-doped ZnO electro-conductive layer

    International Nuclear Information System (INIS)

    Sun, Hongdan; Xia, Bingbo; Liu, Weiwei; Fang, Guoqing; Wu, Jingjing; Wang, Haibo; Zhang, Ruixue; Kaneko, Shingo; Zheng, Junwei; Wang, Hongyu; Li, Decheng

    2015-01-01

    Graphical abstract: Al-doped ZnO (AZO)-coated LiNi 0.5 Mn 1.5 O 4 (LNMO) was prepared by sol–gel method. AZO-coated LNMO electrode shows excellent rate capability and a remarkable improvement in the cyclic performance at a high rate at elevated temperature. - Highlights: • Al-doped ZnO (AZO)-coated LiNi 0.5 Mn 1.5 O 4 (LNMO) was prepared by a traditional sol–gel method. • Al-doped ZnO (AZO) layer grown on the surface of LNMO is high ordered. • At a high rate of 10 C, the discharge capacity of the AZO-coated LNMO electrode can reach 114 mAh g −1 . • Al-doped ZnO (AZO) modification improved cyclic performance of LNMO at high temperatures. - Abstract: Al-doped ZnO (AZO)-coated LiNi 0.5 Mn 1.5 O 4 (LNMO) was prepared by sol–gel method. Transmission electron microscopy (TEM) analysis indicates that AZO layer grown on the surface of LNMO is high ordered. The results of electrochemical performance measurements reveal that the AZO-coated LNMO electrode displays the best rate capability compared with the bare LNMO and ZnO-coated LNMO, even at a high rate of 10 C. The discharge capacity of the AZO-coated LNMO electrode can still reach 114.3 mAh g −1 , about 89% of its discharge capacity at 0.1 C. Moreover, AZO-coated LNMO electrode shows a remarkable improvement in the cyclic performance at a high rate at elevated temperature due to the protective effect of AZO coating layer. The electrode delivers a capacity of 120.3 mAh g −1 with the capacity retention of 95% at 5 C in 50 cycles at 50 °C. The analysis of electrochemical impedance spectra (EIS) indicates that AZO-coated LNMO possesses the lowest charge transfer resistance compared to the bare LNMO and ZnO-coated LNMO, which may be responsible for improved rate capability

  15. How to predict a high rate of inappropriateness for upper endoscopy in an endoscopic centre?

    Science.gov (United States)

    Buri, L; Bersani, G; Hassan, C; Anti, M; Bianco, M A; Cipolletta, L; Di Giulio, E; Di Matteo, G; Familiari, L; Ficano, L; Loriga, P; Morini, S; Pietropaolo, V; Zambelli, A; Grossi, E; Intraligi, M; Tessari, F; Buscema, M

    2010-09-01

    Inappropriateness of upper endoscopy (EGD) indication causes decreased diagnostic yield. Our aim of was to identify predictors of appropriateness rate for EGD among endoscopic centres. A post-hoc analysis of two multicentre cross-sectional studies, including 6270 and 8252 patients consecutively referred to EGD in 44 (group A) and 55 (group B) endoscopic Italian centres in 2003 and 2007, respectively, was performed. A multiple forward stepwise regression was applied to group A, and independently validated in group B. A <70% threshold was adopted to define inadequate appropriateness rate clustered by centre. discrete variability of clustered appropriateness rates among the 44 group A centres was observed (median: 77%; range: 41-97%), and a <70% appropriateness rate was detected in 11 (25%). Independent predictors of centre appropriateness rate were: percentage of patients referred by general practitioners (GP), rate of urgent examinations, prevalence of relevant diseases, and academic status. For group B, sensitivity, specificity and area under receiver operating characteristic curve of the model in detecting centres with a <70% appropriateness rate were 54%, 93% and 0.72, respectively. A simple predictive rule, based on rate of patients referred by GPs, rate of urgent examinations, prevalence of relevant diseases and academic status, identified a small subset of centres characterised by a high rate of inappropriateness. These centres may be presumed to obtain the largest benefit from targeted educational programs. Copyright (c) 2010 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  16. Implementation trial of high performance trace analysis/environmental sampling (HPTA/ES) in uranium centrifuge enrichment plants

    International Nuclear Information System (INIS)

    Nackaerts, H.; Kloeckner, W.; Landresse, G.; MacLean, F.; Betti, M.; Forcina, V.; Hiernaut, T.; Tamborini, G.; Koch, L.; Schenkel, R.

    1999-01-01

    Field trials have demonstrated that the analysis of particles upon swipes obtained from inside nuclear installations provides clear signatures of past operations in that installation. This can offer a valuable tool for gaining assurance regarding the compliance with declared activities and the absence of undeclared activities (e.g. enrichment, reprocessing, and reactor operation) at such sites. This method, known as 'Environmental Sampling' (ES) or 'High Performance Trace Analysis' (HPTA) in EURATOM terminology, is at present being evaluated by the EURATOM Safeguards Directorate (ESD) in order to assess its possible use in nuclear installations within the European Union. It is expected that incorporation of HPTA/ES of sample collection and analysis into routine inspection activities will allow EURATOM to improve the effectiveness of safeguards in these installations and hopefully save inspection resources as well. The EURATOM Safeguards Directorate has therefore performed implementation trials involving the collection of particles by the so-called swipe sampling method in uranium centrifuge enrichment plants and hot cells in the European Union. These samples were subsequently analysed by the Joint Research Centre, Institute for Transuranium Elements (ITU) in Karlsruhe. Sampling points were chosen on the basis of the activities performed in the vicinity and by considering the possible ways through which particles are released, diffused and transported. The aim was to test the efficiency of the method as regards: the collection of enough representative material; the identification of a large enough number of uranium particles; the accurate measurement of the enrichment of the uranium particles found on the swipe; the representativity of the results in respect of past activities in the plant; the capability of detecting whether highly enriched uranium has been produced, used or occasionally transported in a location where low enriched uranium is routinely produced in

  17. High performance liquid chromatography analysis of aliphatic thiols in alimentary supplements and pharmaceuticals using menadione as a new useful derivatization reagent.

    Science.gov (United States)

    Gatti, Rita; Vitellaro, Valeria

    2013-12-04

    The use of menadione (MD) as a pre-column reagent for high performance liquid chromatography (HPLC) analysis of aliphatic thiols is proposed. The reaction was carried out for 5 min at room temperature and pH 8.5. The developed method was applied to the N-acetylcysteine (NAC) analysis of alimentary supplements and pharmaceutical formulations. The effect of the complex matrix was evaluated by the study of the thiol derivatization reaction both in standard and in placebo solutions. The yield of NAC-MD adduct was found to be quantitative at a reagent to thiol molar ratio of about 4 in comparison with an authentic specimen of synthesized NAC adduct, which was characterized by (1)H NMR, IR and UV. The routine chromatographic separations were performed on a Synergi MAX-RP column using a mobile phase consisting of methanol/triethylammonium (TEA) phosphate buffer (pH 3; 0.05 mol L(-1)) 70:30 (v/v) at a flow-rate of 0.4 mL min(-1). UV-diode array detection was used setting the wavelength at λ=260 nm. The validation parameters such as linearity, sensitivity, accuracy, precision, selectivity and ruggedness were found to be highly satisfactory. Similar linear responses were observed by standard and placebo solutions (determination coefficient: 0.9996). Limit of detection was about 0.019 μg g(-1). Intra-day precision (relative standard deviation, R.S.D.) was ≤0.81% for NAC to internal standard (IS) peak area ratio, ≤0.28% and ≤0.32%, respectively, for NAC and IS retention times (tR), without significant differences between intra- and inter-day data. NAC recovery studies gave good results (100.12%) with R.S.D.=1.05%. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Fast and comprehensive analysis of secondary metabolites in cocoa products using ultra high-performance liquid chromatography directly after pressurized liquid extraction.

    Science.gov (United States)

    Damm, Irina; Enger, Eileen; Chrubasik-Hausmann, Sigrun; Schieber, Andreas; Zimmermann, Benno F

    2016-08-01

    Fast methods for the extraction and analysis of various secondary metabolites from cocoa products were developed and optimized regarding speed and separation efficiency. Extraction by pressurized liquid extraction is automated and the extracts are analyzed by rapid reversed-phase ultra high-performance liquid chromatography and normal-phase high-performance liquid chromatography methods. After extraction, no further sample treatment is required before chromatographic analysis. The analytes comprise monomeric and oligomeric flavanols, flavonols, methylxanthins, N-phenylpropenoyl amino acids, and phenolic acids. Polyphenols and N-phenylpropenoyl amino acids are separated in a single run of 33 min, procyanidins are analyzed by normal-phase high-performance liquid chromatography within 16 min, and methylxanthins require only 6 min total run time. A fourth method is suitable for phenolic acids, but only protocatechuic acid was found in relevant quantities. The optimized methods were validated and applied to 27 dark chocolates, one milk chocolate, two cocoa powders and two food supplements based on cocoa extract. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Amplifier with time-invariant trapezoidal shaping and shape-sensitive pileup rejector for high-rate spectroscopy

    International Nuclear Information System (INIS)

    Drndarevic, V.; Ryge, P.; Gozani, T.

    1989-01-01

    An amplifier with trapezoidal pulse shaping was developed for high-rate high-energy gamma spectroscopy using NaI(T1) scintillation detectors. It employs a double delay-line technique for producing a nearly triangular pulse shape combined with a linear circuit for producing a flattopped pulse. Good energy resolution and short resolving time make this amplifier especially suitable for high count rate gamma ray spectroscopy. To provide a versatile high-performance system, it includes a pileup rejector based on inspection of a pileup signal obtained by combining the slow output signal and fast-shaped input signal. The trapezoidal shape provides a short resolving time for minimal occurrence of pileup with a width suitable for presentation to a standard multichannel analyzer. The performance of the system was tested, and the results are presented

  20. Performance Analysis of High-Speed Deep/Shallow Recessed Hybrid Bearing

    OpenAIRE

    Lei Wang; Shuyun Jiang

    2013-01-01

    The present paper proposes a theoretical analysis of the performance of deep/shallow recessed hybrid bearing. It is intended that, on the basis of the numerical results drawn from this study, appropriate shallow recess depth and width can be determined for use in the bearing design process. By adopting bulk flow theory, the turbulent Reynolds equation and energy equation are modified and solved numerically including concentrated inertia effects at the recess edge with different depth and widt...

  1. High performance computations using dynamical nucleation theory

    International Nuclear Information System (INIS)

    Windus, T L; Crosby, L D; Kathmann, S M

    2008-01-01

    Chemists continue to explore the use of very large computations to perform simulations that describe the molecular level physics of critical challenges in science. In this paper, we describe the Dynamical Nucleation Theory Monte Carlo (DNTMC) model - a model for determining molecular scale nucleation rate constants - and its parallel capabilities. The potential for bottlenecks and the challenges to running on future petascale or larger resources are delineated. A 'master-slave' solution is proposed to scale to the petascale and will be developed in the NWChem software. In addition, mathematical and data analysis challenges are described

  2. Exposure reduces negative bias in self-rated performance in public speaking fearful participants.

    Science.gov (United States)

    Cheng, Joyce; Niles, Andrea N; Craske, Michelle G

    2017-03-01

    Individuals with public speaking anxiety (PSA) under-rate their performance compared to objective observers. The present study examined whether exposure reduces the discrepancy between self and observer performance ratings and improved observer-rated performance in individuals with PSA. PSA participants gave a speech in front of a small audience and rated their performance using a questionnaire before and after completing repeated exposures to public speaking. Non-anxious control participants gave a speech and completed the questionnaire one time only. Objective observers watched videos of the speeches and rated performance using the same questionnaire. PSA participants underrated their performance to a greater degree than did controls prior to exposure, but also performed significantly more poorly than did controls when rated objectively. Bias significantly decreased and objective-rated performance significantly increased following completion of exposure in PSA participants, and on one performance measure, anxious participants no longer showed a greater discrepancy between self and observer performance ratings compared to controls. The study employed non-clinical student sample, but the results should be replicated in clinical anxiety samples. These findings indicate that exposure alone significantly reduces negative performance bias among PSA individuals, but additional exposure or additional interventions may be necessary to fully correct bias and performance deficits. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Accelerated partial breast irradiation: An analysis of variables associated with late toxicity and long-term cosmetic outcome after high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Wazer, David E.; Kaufman, Seth; Cuttino, Laurie; Di Petrillo, Thomas; Arthur, Douglas W.

    2006-01-01

    Purpose: To perform a detailed analysis of variables associated with late tissue effects of high-dose-rate (HDR) interstitial brachytherapy accelerated partial breast irradiation (APBI) in a large cohort of patients with prolonged follow-up. Methods and Materials: Beginning in 1995, 75 women with Stage I/II breast cancer were enrolled in identical institutional trials evaluating APBI as monotherapy after lumpectomy. Patients eligible included those with T1-2, N0-1 (≤3 nodes positive), M0 tumors of nonlobular histology with negative surgical margins, no extracapsular nodal extension, and negative results on postexcision mammogram. All patients underwent surgical excision and postoperative irradiation with HDR interstitial brachytherapy. The planning target volume was defined as the excision cavity plus a 2-cm margin. Treatment was delivered with a high-activity Ir-192 source at 3.4 Gy per fraction twice daily for 5 days to a total dose of 34 Gy. Dosimetric analyses were performed with three-dimensional postimplant dose and volume reconstructions. All patients were evaluated at 3-6-month intervals and assessed with a standardized cosmetic rating scale and according to Radiation Therapy Oncology Group late normal tissue toxicity scoring criteria. Clinical and therapy-related features were analyzed for their relationship to cosmetic outcome and toxicity rating. Clinical features analyzed included age, volume of resection, history of diabetes or hypertension, extent of axillary surgery, and systemic therapies. Therapy-related features analyzed included volume of tissue encompassed by the 100%, 150%, and 200% isodose lines (V100, V150, and V200, respectively), the dose homogeneity index (DHI), number of source dwell positions, and planar separation. Results: The median follow-up of all patients was 73 months (range, 43-118 months). The cosmetic outcome at last follow-up was rated as excellent, good, and fair/poor in 67%, 24%, and 9% of patients, respectively

  4. Comparative performance of high-fidelity training models for flexible ureteroscopy: Are all models effective?

    Directory of Open Access Journals (Sweden)

    Shashikant Mishra

    2011-01-01

    Full Text Available Objective: We performed a comparative study of high-fidelity training models for flexible ureteroscopy (URS. Our objective was to determine whether high-fidelity non-virtual reality (VR models are as effective as the VR model in teaching flexible URS skills. Materials and Methods: Twenty-one trained urologists without clinical experience of flexible URS underwent dry lab simulation practice. After a warm-up period of 2 h, tasks were performed on a high-fidelity non-VR (Uro-scopic Trainer TM ; Endo-Urologie-Modell TM and a high-fidelity VR model (URO Mentor TM . The participants were divided equally into three batches with rotation on each of the three stations for 30 min. Performance of the trainees was evaluated by an expert ureteroscopist using pass rating and global rating score (GRS. The participants rated a face validity questionnaire at the end of each session. Results: The GRS improved statistically at evaluation performed after second rotation (P<0.001 for batches 1, 2 and 3. Pass ratings also improved significantly for all training models when the third and first rotations were compared (P<0.05. The batch that was trained on the VR-based model had more improvement on pass ratings on second rotation but could not achieve statistical significance. Most of the realistic domains were higher for a VR model as compared with the non-VR model, except the realism of the flexible endoscope. Conclusions: All the models used for training flexible URS were effective in increasing the GRS and pass ratings irrespective of the VR status.

  5. Dose-rate determination by radiochemical analysis

    International Nuclear Information System (INIS)

    Mangini, A.; Pernicka, E.; Wagner, G.A.

    1983-01-01

    At the previous TL Specialist Seminr we had suggested that α-counting is an unsuitable technique for dose-rate determination due to overcounting effects. This is confirmed by combining α-counting, neutron activation analysis, fission track counting, α-spectrometry on various pottery samples. One result of this study is that disequilibrium in the uranium decay chain alone cannot account for the observed discrepancies between α-counting and chemical analysis. Therefore we propose for routine dose-rate determination in TL dating to apply chemical analysis of the radioactive elements supplemented by an α-spectrometric equilibrium check. (author)

  6. An improved high-performance lithium-air battery.

    Science.gov (United States)

    Jung, Hun-Gi; Hassoun, Jusef; Park, Jin-Bum; Sun, Yang-Kook; Scrosati, Bruno

    2012-06-10

    Although dominating the consumer electronics markets as the power source of choice for popular portable devices, the common lithium battery is not yet suited for use in sustainable electrified road transport. The development of advanced, higher-energy lithium batteries is essential in the rapid establishment of the electric car market. Owing to its exceptionally high energy potentiality, the lithium-air battery is a very appealing candidate for fulfilling this role. However, the performance of such batteries has been limited to only a few charge-discharge cycles with low rate capability. Here, by choosing a suitable stable electrolyte and appropriate cell design, we demonstrate a lithium-air battery capable of operating over many cycles with capacity and rate values as high as 5,000 mAh g(carbon)(-1) and 3 A g(carbon)(-1), respectively. For this battery we estimate an energy density value that is much higher than those offered by the currently available lithium-ion battery technology.

  7. Individual and contextual factors associated with community health workers' performance in Nyanza Province, Kenya: a multilevel analysis.

    Science.gov (United States)

    Kawakatsu, Yoshito; Sugishita, Tomohiko; Tsutsui, Junya; Oruenjo, Kennedy; Wakhule, Stephen; Kibosia, Kennedy; Were, Eric; Honda, Sumihisa

    2015-10-01

    Several African and South Asian countries are currently investing in new cadres of community health workers (CHWs) as a major part of strategies aimed at reaching the Millennium Development Goals. However, one review concluded that community health workers did not consistently provide services likely to have substantial effects on health and that quality was usually poor. The objective of this research was to assess the CHWs' performance in Western Kenya and describe determinants of that performance using a multilevel analysis of the two levels, individual and supervisor/community. This study conducted three surveys between August and September 2011 in Nyanza Province, Kenya. The participants of the three surveys were all 1,788 active CHWs, all their supervisors, and 2,560 randomly selected mothers who had children aged 12 to 23 months. CHW performance was generated by three indicators: reporting rate, health knowledge and household coverage. Multilevel analysis was performed to describe the determinants of that performance. The significant factors associated with the CHWs' performance were their marital status, educational level, the size of their household, their work experience, personal sanitation practice, number of supervisions received and the interaction between their supervisors' better health knowledge and the number of supervisions. A high quality of routine supervisions is one of the key interventions in sustaining a CHW's performance. In addition, decreasing the dropout rate of CHWs is important both for sustaining their performance and for avoiding the additional cost of replacing them. As for the selection criteria of new CHWs, good educational status, availability of supporters for household chores and good sanitation practices are all important in selecting CHWs who can maintain their high performance level.

  8. Retrofit Weight-Loss Outcomes at 6, 12, and 24 Months and Characteristics of 12-Month High Performers: A Retrospective Analysis.

    Science.gov (United States)

    Painter, Stefanie; Ditsch, Gary; Ahmed, Rezwan; Hanson, Nicholas Buck; Kachin, Kevin; Berger, Jan

    2016-08-22

    Obesity is the leading cause of preventable death costing the health care system billions of dollars. Combining self-monitoring technology with personalized behavior change strategies results in clinically significant weight loss. However, there is a lack of real-world outcomes in commercial weight-loss program research. Retrofit is a personalized weight management and disease-prevention solution. This study aimed to report Retrofit's weight-loss outcomes at 6, 12, and 24 months and characterize behaviors, age, and sex of high-performing participants who achieved weight loss of 10% or greater at 12 months. A retrospective analysis was performed from 2011 to 2014 using 2720 participants enrolled in a Retrofit weight-loss program. Participants had a starting body mass index (BMI) of >25 kg/m² and were at least 18 years of age. Weight measurements were assessed at 6, 12, and 24 months in the program to evaluate change in body weight, BMI, and percentage of participants who achieved 5% or greater weight loss. A secondary analysis characterized high-performing participants who lost ≥10% of their starting weight (n=238). Characterized behaviors were evaluated, including self-monitoring through weigh-ins, number of days wearing an activity tracker, daily step count average, and engagement through coaching conversations via Web-based messages, and number of coaching sessions attended. Average weight loss at 6 months was -5.55% for male and -4.86% for female participants. Male and female participants had an average weight loss of -6.28% and -5.37% at 12 months, respectively. Average weight loss at 24 months was -5.03% and -3.15% for males and females, respectively. Behaviors of high-performing participants were assessed at 12 months. Number of weigh-ins were greater in high-performing male (197.3 times vs 165.4 times, P=.001) and female participants (222 times vs 167 times, Pactivity tracker days and average steps per day were greater in high-performing females (304.7 vs

  9. Latent Cluster Analysis of Instructional Practices Reported by High- and Low-performing Mathematics Teachers in Four Countries

    OpenAIRE

    Cheng, Qiang; Hsu, Hsien-Yuan

    2017-01-01

    Using Trends in International Mathematics and Science Study (TIMSS) 2011 eighth-grade international dataset, this study explored the profiles of instructional practices reported by high- and low-performing mathematics teachers across the US, Finland, Korea, and Russia. Concepts of conceptual teaching and procedural teaching were used to frame the design of the current study. Latent cluster analysis was applied in the investigation of the profiles of mathematics teachers’ instructional practic...

  10. Use of a high repetition rate neutron generator for in vivo body composition measurements via neutron inelastic scattering

    International Nuclear Information System (INIS)

    Kehayias, J.J.; Ellis, K.J.; Cohn, S.H.; Weinlein, J.H.

    1986-01-01

    A small D-T neutron generator with a high pulse rate is used for the in vivo measurement of body carbon, oxygen and hydrogen. The core of the neutron generator is a 13 cm-long Zetatron tube pulsed at a rate of 10 kHz delivering 10 3 to 10 4 neutrons per pulse. A target-current feedback system regulates the source of the accelerator to assure constant neutron output. Carbon is measured by detecting the 4.44 MeV γ-rays from inelastic scattering. The short half-life of the 4.44 MeV state of carbon requires detection of the γ-rays during the 10 μs neutron pulse. Generators with low pulsing rate were found inappropriate for carbon measurements because of their low duty-cycle (high neutron output during the pulse). In vivo measurements were performed with normal volunteers using a scanning bed facility for a dose less than 25 mrem. This technique offers medical as well as general bulk analysis applications. 8 refs., 5 figs

  11. High performance sinter-HIP for hard metals

    International Nuclear Information System (INIS)

    Hongxia Chen; Deming Zhang; Yang Li; Jingping Chen

    2001-01-01

    The horizontal sinter-HIP equipment with great charge capacity and high performance, developed and manufactured by Central Iron and Steel Research Institute(CISRI), is mainly used for sintering and condensation of hard metals. This equipment is characterized by large hot zone, high heating speed, good temperature uniformity and fast cooling system. The equipment can provide uniform hot zone with temperature difference less than 6 o C at 1500-1600 o C and 6-10 MPa by controlling temperature, pressure and circulation of gas precisely. Using large scale horizontal sinter-HIP equipment to produce hard matals have many advantages such as stable quality, high efficiency of production, high rate of finished products and low production cost, so this equipment is a good choice for manufacturer of hard metals. (author)

  12. High-rate synthesis of phosphine-stabilized undecagold nanoclusters using a multilayered micromixer

    International Nuclear Information System (INIS)

    Jin, Hyung Dae; Chang, Chih-Hung; Garrison, Anna; Tseng, T; Paul, Brian K

    2010-01-01

    Growth in the potential applications of nanomaterials has led to a focus on the development of new manufacturing approaches for these materials. In particular, an increased demand due to the unique properties of nanomaterials requires a substantial yield of high-performance materials and a simultaneous reduction in the environmental impact of these processes. In this paper, a high-rate production of phosphine-stabilized undecagold nanoclusters was achieved using a layer-up strategy which involves the use of microlamination architectures; the patterning and bonding of thin layers of material (laminae) to create a multilayered micromixer in the range of 25-250 μm thick was used to step up the production of phosphine-stabilized undecagold nanoclusters. The continuous production of highly monodispersed phosphine-stabilized undecagold nanoclusters at a rate of about 11.8 (mg s -1 ) was achieved using a microreactor with a size of 1.687 cm 3 . This result is about 500 times over conventional batch syntheses based on the production rate per reactor volume.

  13. Exploring the relationships among performance-based functional ability, self-rated disability, perceived instrumental support, and depression: a structural equation model analysis.

    Science.gov (United States)

    Weil, Joyce; Hutchinson, Susan R; Traxler, Karen

    2014-11-01

    Data from the Women's Health and Aging Study were used to test a model of factors explaining depressive symptomology. The primary purpose of the study was to explore the association between performance-based measures of functional ability and depression and to examine the role of self-rated physical difficulties and perceived instrumental support in mediating the relationship between performance-based functioning and depression. The inclusion of performance-based measures allows for the testing of functional ability as a clinical precursor to disability and depression: a critical, but rarely examined, association in the disablement process. Structural equation modeling supported the overall fit of the model and found an indirect relationship between performance-based functioning and depression, with perceived physical difficulties serving as a significant mediator. Our results highlight the complementary nature of performance-based and self-rated measures and the importance of including perception of self-rated physical difficulties when examining depression in older persons. © The Author(s) 2014.

  14. Experimental investigation of the behaviour of tungsten and molybdenum alloys at high strain-rate and temperature

    CERN Document Server

    Scapin, Martina; Carra, Federico; Peroni, Lorenzo

    2015-01-01

    The introduction in recent years of new, extremely energetic particle accelerators such as the Large Hadron Collider (LHC) gives impulse to the development and testing of refractory metals and alloys based on molybdenum and tungsten to be used as structural materials. In this perspective, in this work the experimental results of a tests campaign on Inermet® IT180 and pure Molybdenum (sintered by two different producers) are presented. The investigation of the mechanical behaviour was performed in tension varying the strain-rates, the temperatures and both of them. Overall six orders of magnitude in strain-rate (between 10−3 and 103 s−1) were covered, starting from quasi-static up to high dynamic loading conditions. The high strain-rate tests were performed using a direct Hopkinson Bar setup. Both in quasi-static and high strain-rate conditions, the heating of the specimens was obtained with an induction coil system, controlled in feedback loop, based on measurements from thermocouples directly welded on...

  15. ANSI/ASHRAE/IES Standard 90.1-2016 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eley, Charles [Eley and Associates, Hobe Sound, FL (United States)

    2017-09-29

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1-2016 (Standard 90.1-2016). The PRM can be used to demonstrate compliance with the standard and to rate the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. Use of the PRM for demonstrating compliance with Standard 90.1 is a new feature of the 2016 edition. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM.

  16. High Performance Marine Vessels

    CERN Document Server

    Yun, Liang

    2012-01-01

    High Performance Marine Vessels (HPMVs) range from the Fast Ferries to the latest high speed Navy Craft, including competition power boats and hydroplanes, hydrofoils, hovercraft, catamarans and other multi-hull craft. High Performance Marine Vessels covers the main concepts of HPMVs and discusses historical background, design features, services that have been successful and not so successful, and some sample data of the range of HPMVs to date. Included is a comparison of all HPMVs craft and the differences between them and descriptions of performance (hydrodynamics and aerodynamics). Readers will find a comprehensive overview of the design, development and building of HPMVs. In summary, this book: Focuses on technology at the aero-marine interface Covers the full range of high performance marine vessel concepts Explains the historical development of various HPMVs Discusses ferries, racing and pleasure craft, as well as utility and military missions High Performance Marine Vessels is an ideal book for student...

  17. Analysis and Design of High-Order Parallel Resonant Converters

    Science.gov (United States)

    Batarseh, Issa Eid

    1990-01-01

    In this thesis, a special state variable transformation technique has been derived for the analysis of high order dc-to-dc resonant converters. Converters comprised of high order resonant tanks have the advantage of utilizing the parasitic elements by making them part of the resonant tank. A new set of state variables is defined in order to make use of two-dimensional state-plane diagrams in the analysis of high order converters. Such a method has been successfully used for the analysis of the conventional Parallel Resonant Converters (PRC). Consequently, two -dimensional state-plane diagrams are used to analyze the steady state response for third and fourth order PRC's when these converters are operated in the continuous conduction mode. Based on this analysis, a set of control characteristic curves for the LCC-, LLC- and LLCC-type PRC are presented from which various converter design parameters are obtained. Various design curves for component value selections and device ratings are given. This analysis of high order resonant converters shows that the addition of the reactive components to the resonant tank results in converters with better performance characteristics when compared with the conventional second order PRC. Complete design procedure along with design examples for 2nd, 3rd and 4th order converters are presented. Practical power supply units, normally used for computer applications, were built and tested by using the LCC-, LLC- and LLCC-type commutation schemes. In addition, computer simulation results are presented for these converters in order to verify the theoretical results.

  18. Analysis of Nitro-aromatic and Nitramine Explosives by Atmospheric Pressure Chemical Ionization / High Performance Liquid Chromatography / Mass Spectrometry / Mass Spectrometry

    International Nuclear Information System (INIS)

    Hicks, B.J.; Han, W.; Robben, J.R.

    2009-01-01

    This procedure is capable of separating and quantifying twenty-nine high explosives and internal surrogates with a single injection. After the initial preparation step, the sample is introduced to the high performance liquid chromatograph for target separation, ionized by atmospheric pressure chemical ionization and the explosives of interest are isolated / quantified by mass spectrometry / mass spectrometry. Concentrations of the target explosives are measured relative to the response of both internal and external standard concentrations. A C-18 reverse phase high performance liquid chromatograph column is used for separation. Ionization is performed using both positive and negative atmospheric pressure chemical ionization resulting in a molecular ion with little fragmentation. These ions are isolated at the first quadrupole of the mass spectrometer, dissociated by collision with argon in the collision cell and the resulting daughter ions are isolated at the second quadrupole. These daughter ions then reach the detector where they are quantified. To date this procedure represents the most thorough high performance liquid chromatography / mass spectrometry / mass spectrometry explosives analysis available in the environmental chemistry market. (authors)

  19. Distance Based Root Cause Analysis and Change Impact Analysis of Performance Regressions

    Directory of Open Access Journals (Sweden)

    Junzan Zhou

    2015-01-01

    Full Text Available Performance regression testing is applied to uncover both performance and functional problems of software releases. A performance problem revealed by performance testing can be high response time, low throughput, or even being out of service. Mature performance testing process helps systematically detect software performance problems. However, it is difficult to identify the root cause and evaluate the potential change impact. In this paper, we present an approach leveraging server side logs for identifying root causes of performance problems. Firstly, server side logs are used to recover call tree of each business transaction. We define a novel distance based metric computed from call trees for root cause analysis and apply inverted index from methods to business transactions for change impact analysis. Empirical studies show that our approach can effectively and efficiently help developers diagnose root cause of performance problems.

  20. Financial Prospect to The Application of High Rate Water Treatment Plant System

    Directory of Open Access Journals (Sweden)

    Mohajit Mohajit

    2015-10-01

    Full Text Available The High Rate Water Treatment Plant (HR-WTP system, which is inexpensive, effective and efficient, has been developed to reduce the common operational problems, and also as an alternative for the development of water treatment plant systems capacity in Indonesia.Implementation of HR-WTP system in up-rating of the Dekeng-WTP system at PDAM Kota Bogor proved successful in increasing the plant capacity from its original of 500 Lps to more than 1200 Lps. The performance of the WTP system was also significantly improved from poor performance to very good performance.The investment cost for up-rating proved competitive when compared to alternatively constructing a new WTP system with an equivalent capacity and performance. Application of HR-WTP systems for the development of WTP system in Indonesia, i.e. rehabilitation, up-grading, and up-rating, as well as construction of a new WTP system, is expected to bring technical, financial, and economic benefits. This new approach might be an innovative solution to the challenge of Millennium Development Goals in Water Supply Sector in Indonesia, where an additional capacity of ca 150,000 Lps should be developed within a 15 years period with an estimated budget of US $1.5 billions. This budget might be reduced to less than 50% through the application of the HR-WTP system.