WorldWideScience

Sample records for high-pressure polarized 3he

  1. The SLAC high-density gaseous polarized 3He target

    International Nuclear Information System (INIS)

    Johnson, J.R.; Chupp, T.E.; Smith, T.B.; Cates, G.D.; Driehuys, B.; Middleton, H.; Newbury, N.R.; Hughes, E.W.; Meyer, W.

    1995-01-01

    A large-scale high-pressure gaseous 3 He polarized target has been developed for use with a high-intensity polarized electron beam at the Stanford Linear Accelerator Center. This target was used successfully in an experiment to study the spin structure of the neutron. The target provided an areal density of about 7x10 21 nuclei/cm 2 and operated at 3 He polarizations between about 30% and 40% for the six-week duration of the experiment. ((orig.))

  2. Development of polarized {sup 3}He filter for polarized neutron experiment

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, K.; Sato, H.; Yoshimi, A.; Asahi, K. [Tokyo Inst. of Tech. (Japan). Faculty of Science; Masuda, Y.; Muto, S.; Ishimoto, S.; Morimoto, K.

    1996-08-01

    A high-pressure polarized {sup 3}He gas cell, pumped with two diode lasers, has been developed at KEK for use as a polarizer and a spin analyzer for low energy neutrons. The polarization attained of {sup 3}He was determined through the measurement of the transmission of the unpolarized neutrons through the {sup 3}He cell. So far we obtained P{sub He}=18% at 10 atm and P{sub He}=12% at 20 atm. (author)

  3. Metastability-exchange optical pumping of 3He for neutron polarizers

    International Nuclear Information System (INIS)

    Gentile, T.R.; Thompson, A.K.; Snow, W.M.

    1995-01-01

    Research is underway at NIST and IU to develop neutron polarizers that are based on polarized 3 He. Such polarizers rely on the strong spin dependence of the cross section for neutron capture by polarized 3 He. Two methods can produce the high density of polarized 3 He gas (10 19 -10 20 cm -3 ) required for an effective neutron polarizer: spin-exchange optical pumping, which is performed directly at high pressure (1-10 bar), and metastability-exchange optical pumping, in which the gas is polarized at low pressure (1 mbar) and then compressed. While we are pursuing both methods, progress in the metastable method will be discussed. The features of the metastable method are the high rate at which the gas can be polarized and the inherent separation of the optical pumping and target cells. In a landmark achievement, researchers at the Univ. of Mainz have developed a piston compressor that can fill a 130 cm 3 cell to a pressure of 7 bar of 45% polarized 3 He gas in 2 hours. We plan to develop a compressor and test it at the NIST Cold Neutron Research Facility. We have constructed a metastable-pumping apparatus at NIST and have obtained 76% polarization with a pumping rate of 1.2 x 10 18 atoms/sec in a 0.4 mbar, 270 cm 3 cell

  4. Phase equilibrium in a polarized saturated 3He-4He mixture

    International Nuclear Information System (INIS)

    Rodrigues, A.; Vermeulen, G.

    1997-01-01

    We present experimental results on the phase equilibrium of a saturated 3 He- 4 He mixture, which has been cooled to a temperature of 10-15 mK and polarized in a 4 He circulating dilution refrigerator to a stationary polarization of 15 %, 7 times higher than the equilibrium polarization in the external field of 7 T. The pressure dependence of the polarization enhancement in the refrigerator shows that the molar susceptibilities of the concentrated and dilute phase of a saturated 3 He- 4 He mixture are equal at p = 2.60 ± 0.04 bar. This result affects the Fermi liquid parameters of the dilute phase. The osmotic pressure in the dilute phase has been measured as a function of the polarization of the coexisting concentrated phase up to 15 %. We find that the osmotic pressure at low polarization ( < 7 % ) agrees well with thermodynamics using the new Fermi liquid parameters of the dilute phase

  5. Experimental considerations on producing highly polarized liquid 3He in a matrix of solid 4He

    International Nuclear Information System (INIS)

    Greenberg, A.S.; Hebral, B.; Papoular, M.; Beal-Monod, M.T.

    1980-01-01

    Two experiments are briefly reviewed in which droplets of 3 He were formed in solid 4 He. These experiments indicate such conditions are favorable for the production of quasi-stable highly polarized liquid 3 He. A solid solution of dilute 3 He in 4 He is proposed as a promising system to produce experimentally realizable highly polarized liquid 3 He using the Castaing-Nozieres decompression

  6. Optimum transmission for a 3He neutron polarizer

    International Nuclear Information System (INIS)

    Tasset, F.; Ressouche, E.

    1995-01-01

    Following recent achievements in polarizing gaseous 3 He targets by optical pumping at room temperature, polarized helium-3 is now the most promising polarizer for thermal and epithermal neutrons and should soon compete favorably with existing Heusler polarizing crystals. Because it is gaseous, a degree of freedom exists in such a filter: the pressure of the gas in the cell. This parameter allows a choice to be made in the filter design: for a given polarization of 3 He, one is able to increase the pressure, to favor neutron beam polarization, or to stay at relatively low pressure to favor the filter's transmission. In this paper, we discuss this point in the framework of a classical polarized neutron experiment, and we compare our more general results with the quality factor Q=P√(T), which is generally taken as standard for such a filter. (orig.)

  7. Production of highly polarized 3He using spectrally narrowed diode laser array bars

    International Nuclear Information System (INIS)

    Chann, B.; Babcock, E.; Anderson, L.W.; Walker, T.G.; Chen, W.C.; Smith, T.B.; Thompson, A.K.; Gentile, T.R.

    2003-01-01

    We have produced 70%-75% 3 He polarization by spin-exchange optical pumping in cells ≅100 cm 3 in volume. The polarization achieved is consistent with known spin-exchange and spin-relaxation rates, but only when the recently discovered temperature dependence of 3 He relaxation is included. Absolute 3 He polarization measurements were performed using two different methods in two different laboratories. The results were obtained with either a spectrally narrowed laser or one type of broadband laser. Based on tests of several larger cells at pressures near 1 bar, we find that the power required to reach the same polarization is typically three times lower for the spectrally narrowed laser. This last result indicates that spectrally narrowed lasers will be important for obtaining the highest polarization in large volume neutron spin filters. Polarization in excess of 55% as obtained in cells up to 640 cm 3 in volume and 70% polarization is anticipated with available increases in spectrally narrowed laser power

  8. Spin polarized 3He: a ''new'' quantum fluid

    International Nuclear Information System (INIS)

    Lhuillier, C.; Laloe, F.

    1979-01-01

    The physical properties of a 3 He fluid are studied, in which all nuclear spins are parallel to each other (fully polarized 3 He). At low temperatures, significant differences can exist between this polarized fluid and normal 3 He. The origin of these differences is purely quantum mechanical and arises from the Pauli exclusion principle. At low densities, only the transport properties of the gas are modified. At higher densities. The equilibrium properties (virial coefficients) are also changed by the nuclear polarization. Changes of the liquid-vapour or liquid-solid equilibrium pressures, as well as modifications of the 3 He- 4 He mixture phase diagram are predicted. This article gives a preliminary theoretical study of these new effects. Experimental prospects are briefly discussed [fr

  9. Calculations of static properties of spin-polarized 3He--4He mixtures

    International Nuclear Information System (INIS)

    Owers-Bradley, J.R.; Bowley, R.M.; Main, P.C.

    1985-01-01

    The theory of dilute mixtures of 3 He in 4 He that have been polarized by a strong magnetic field is developed. The interaction between the quasiparticles is taken to be constant, an approximation valid at low temperatures. The polarization of the mixture depends on the strength of the interaction. The internal energy, the specific heat, the osmotic pressure, and the velocity of second sound are also calculated. The specific heat is relatively insensitive to the interaction, but it does change significantly with magnetic field. The osmotic pressure is more sensitive to the effects of the interaction for some 3 He concentrations and temperatures. The velocity of second sound behaves qualitatively like the osmotic pressure. The measurement of these quantities as a function of temperature and magnetic field is discussed with a view to obtaining the strength of the interaction between quasiparticles

  10. Neutron polarization in polarized 3He targets

    International Nuclear Information System (INIS)

    Friar, J.L.; Gibson, B.F.; Payne, G.L.; Bernstein, A.M.; Chupp, T.E.

    1990-01-01

    Simple formulas for the neutron and proton polarizations in polarized 3 He targets are derived assuming (1) quasielastic final states; (2) no final-state interactions; (3) no meson-exchange currents; (4) large momentum transfers; (5) factorizability of 3 He SU(4) response-function components. Numerical results from a wide variety of bound-state solutions of the Faddeev equations are presented. It is found that this simple model predicts the polarization of neutrons in a fully polarized 3 He target to be 87%, while protons should have a slight residual polarization of -2.7%. Numerical studies show that this model works very well for quasielastic electron scattering

  11. Polarized (3) He Spin Filters for Slow Neutron Physics.

    Science.gov (United States)

    Gentile, T R; Chen, W C; Jones, G L; Babcock, E; Walker, T G

    2005-01-01

    Polarized (3)He spin filters are needed for a variety of experiments with slow neutrons. Their demonstrated utility for highly accurate determination of neutron polarization are critical to the next generation of betadecay correlation coefficient measurements. In addition, they are broadband devices that can polarize large area and high divergence neutron beams with little gamma-ray background, and allow for an additional spin-flip for systematic tests. These attributes are relevant to all neutron sources, but are particularly well-matched to time of flight analysis at spallation sources. There are several issues in the practical use of (3)He spin filters for slow neutron physics. Besides the essential goal of maximizing the (3)He polarization, we also seek to decrease the constraints on cell lifetimes and magnetic field homogeneity. In addition, cells with highly uniform gas thickness are required to produce the spatially uniform neutron polarization needed for beta-decay correlation coefficient experiments. We are currently employing spin-exchange (SE) and metastability-exchange (ME) optical pumping to polarize (3)He, but will focus on SE. We will discuss the recent demonstration of 75 % (3)He polarization, temperature-dependent relaxation mechanism of unknown origin, cell development, spectrally narrowed lasers, and hybrid spin-exchange optical pumping.

  12. Development of high-performance alkali-hybrid polarized 3He targets for electron scattering

    Science.gov (United States)

    Singh, Jaideep T.; Dolph, P. A. M.; Tobias, W. A.; Averett, T. D.; Kelleher, A.; Mooney, K. E.; Nelyubin, V. V.; Wang, Yunxiao; Zheng, Yuan; Cates, G. D.

    2015-05-01

    Background: Polarized 3He targets have been used as effective polarized neutron targets for electron scattering experiments for over twenty years. Over the last ten years, the effective luminosity of polarized 3He targets based on spin-exchange optical pumping has increased by over an order of magnitude. This has come about because of improvements in commercially-available lasers and an improved understanding of the physics behind the polarization process. Purpose: We present the development of high-performance polarized 3He targets for use in electron scattering experiments. Improvements in the performance of polarized 3He targets, target properties, and operating parameters are documented. Methods: We utilize the technique of alkali-hybrid spin-exchange optical pumping to polarize the 3He targets. Spectrally narrowed diode lasers used for the optical pumping greatly improved the performance. A simulation of the alkali-hybrid spin-exchange optical pumping process was developed to provide guidance in the design of the targets. Data was collected during the characterization of 24 separate glass target cells, each of which was constructed while preparing for one of four experiments at Jefferson Laboratory in Newport News, Virginia. Results: From the data obtained we made determinations of the so-called X -factors that quantify a temperature-dependent and as-yet poorly understood spin-relaxation mechanism that limits the maximum achievable 3He polarization to well under 100%. The presence of the X -factor spin-relaxation mechanism was clearly evident in our data. Good agreement between the simulation and the actual target performance was obtained by including details such as off-resonant optical pumping. Included in our results is a measurement of the K -3He spin-exchange rate coefficient kseK=(7.46 ±0.62 ) ×10-20cm3/s over the temperature range 503 K to 563 K. Conclusions: In order to achieve high performance under the operating conditions described in this paper

  13. Polarimetry on dense samples of spin-polarized 3He by magnetostatic detection

    International Nuclear Information System (INIS)

    Wilms, E.; Ebert, M.; Heil, W.; Surkau, R.

    1997-01-01

    A very sensitive low-field fluxgate magnetometer is used to detect the static magnetic field produced by dense samples of spin-polarized 3 He gas contained in spherical glass cells at pressures around several bars. The 3 He nuclear polarization can be extracted with high precision ΔP/P<1% by utilizing magnetostatic detection in combination with adiabatic fast-passage spin reversal. The polarization losses can be kept well below 0.1% thus making this type of polarimetry almost non-destructive. More simply even, P can be measured with reduced accuracy by the change of field when the cell is removed from the fluxgate. In this case the accuracy is limited to about 10% due to the uncertainties about the susceptibilities of the cell walls. (orig.)

  14. Opportunities for Polarized He-3 in RHIC and EIC

    Energy Technology Data Exchange (ETDEWEB)

    Aschenauer E.; Deshpande, A.; Fischer, W.; Derbenev, S.; Milner, R.; Roser, T.; Zelenski, A.

    2011-10-01

    The workshop on opportunities for polarized He-3 in RHIC and EIC was targeted at finding practical ways of implementing and using polarized He-3 beams. Polarized He-3 beams will provide the unique opportunity for first measurements, i.e, to a full quark flavor separation measuring single spin asymmetries for p{sup +}, p{sup -} and p{sup 0} in hadron-hadron collisions. In electron ion collisions the combination of data recorded with polarized electron proton/He-3 beams allows to determine the quark flavor separated helicity and transverse momentum distributions. The workshop had sessions on polarized He-3 sources, the physics of colliding polarized He-3 beams, polarimetry, and beam acceleration in the AGS Booster, AGS, RHIC, and ELIC. The material presented at the workshop will allow making plans for the implementation of polarized He-3 beams in RHIC.

  15. Magnetization-dependent viscosity in brute-force-polarized liquid 3He

    DEFF Research Database (Denmark)

    Vermeulen, G.A.; Schuhl, A.; Joffrin, J.

    1988-01-01

    A new method to measure the magnetization dependence of the viscosity in polarized liquid He3 is presented. The magnetization is obtained by "brute-force polarization" at 45 mK in magnetic fields up to 11 T; it is subsequently destroyed by saturation of the NMR signal. Our result, a relative...... increase of the viscosity of (31.5)×10-3 at 3.9% polarization and a pressure of 30 bars, disagrees with a prediction based on the "nearly metamagnetic" model....

  16. Measurement of the polarized neutron---polarized 3He total cross section

    International Nuclear Information System (INIS)

    Keith, C.D.; Gould, C.R.; Haase, D.G.; Seely, M.L.; Huffman, P.R.; Roberson, N.R.; Tornow, W.; Wilburn, W.S.

    1995-01-01

    The first measurements of polarized neutron--polarized 3 He scattering in the few MeV energy region are reported. The total cross section difference Δσ T for transversely polarized target and beam has been measured for neutron energies between 1.9 and 7.5 MeV. Comparison is made to predictions of Δσ T using various descriptions of the 4 He continuum. A brute-force polarized target of solid 3 He has been developed for these measurements. The target is 4.3x10 22 atoms/cm 2 thick and is polarized to 38% at 7 Telsa and 12 mK. copyright 1995 American Institute of Physics

  17. Elastic scattering of polarized neutrons by 3He at low energy

    International Nuclear Information System (INIS)

    Drigo, L.; Tornielli, G.; Zannoni, G.

    1982-01-01

    Elastic scattering by 3 He for 1.67, 2.43, 3.0, 3.4 and 7.8 MeV neutron beams of known polarization was measured at seven angles from 25 0 to 155 0 using a high pressure gas scintillation counter. The geometrical and multiple scattering effects were accounted for by the Monte Carlo technique. The corrected results were compared with previous experimental data and with the existing predictions based on microscopic calculations and phenomenological analyses. (author)

  18. Polarimetry on dense samples of spin-polarized {sup 3}He by magnetostatic detection

    Energy Technology Data Exchange (ETDEWEB)

    Wilms, E.; Ebert, M.; Heil, W.; Surkau, R. [Mainz Univ. (Germany). Inst. fuer Physik

    1997-12-21

    A very sensitive low-field fluxgate magnetometer is used to detect the static magnetic field produced by dense samples of spin-polarized {sup 3}He gas contained in spherical glass cells at pressures around several bars. The {sup 3}He nuclear polarization can be extracted with high precision {Delta}P/P<1% by utilizing magnetostatic detection in combination with adiabatic fast-passage spin reversal. The polarization losses can be kept well below 0.1% thus making this type of polarimetry almost non-destructive. More simply even, P can be measured with reduced accuracy by the change of field when the cell is removed from the fluxgate. In this case the accuracy is limited to about 10% due to the uncertainties about the susceptibilities of the cell walls. (orig.). 29 refs.

  19. Experiment on the melting pressure of spin polarized He3

    DEFF Research Database (Denmark)

    Chapellier, M.; Olsen, M.; Rasmussen, Finn Berg

    1981-01-01

    In liquid He in a Pomeranchuk cell, the melting curve has been observed to be suppressed, presumably in regions with a strong local spin polarization. In the temperature range 30-50 mK the observed suppression was 60-80 kPa. The corresponding local polarization is estimated, in a crude model...

  20. Test of sup 3 He-based neutron polarizers at NIST

    CERN Document Server

    Jones, G L; Thompson, A K; Chowdhuri, Z; Dewey, M S; Snow, W M; Wietfeldt, F E

    2000-01-01

    Neutron spin filters based on polarized sup 3 He are useful over a wide neutron energy range and have a large angular acceptance among other advantages. Two optical pumping methods, spin-exchange and metastability-exchange, can produce the volume of highly polarized sup 3 He gas required for such neutron spin filters. We report a test of polarizers based on each of these two methods on a new cold, monochromatic neutron beam line at the NIST Center for Neutron Research.

  1. Towards helium-3 neutron polarizers

    International Nuclear Information System (INIS)

    Tasset, F.

    1995-01-01

    With a large absorption cross-section entirely due to antiparallel spin capture, polarized helium-3 is presently the most promising broad-band polarizer for thermal and epithermal neutrons. Immediate interest was raised amongst the neutron community when a dense gaseous 3 He polarizer was used for the first time in 1988, on a pulsed neutron beam at Los Alamos. With 20 W of laser power on a 30 cm long, 8.6 atm target, 40% 3 He polarization was achieved in a recent polarized electron scattering experiment at SLAC. In this technique the 3 He nuclei are polarized directly at an appropriate high pressure through spin-exchange collisions with a thick, optically pumped rubidium vapor. A different and competitive approach is being presently developed at Mainz University in collaboration with ENS Paris and now the ILL. A discharge is established in pure 3 He at low pressure producing excited metastable atoms which can be optically pumped with infra-red light. Highly effective exchange collision with the atoms remaining in the ground state quickly produces 75% polarization at 1.5 mbar. A truly non-magnetic system then compresses the polarized gas up to several bars as required. The most recent machine comprises a two-stage glass-titanium compressor. In less than 1 h it can inflate a 100 cm 3 target cell with three bars of polarized gas. The very long relaxation times (several days) now being obtained at high pressure with a special metallic coating on the glass walls, the polarized cell can be detached and inserted in the neutron beam as polarizer. We expect 50% 3 He-polarization to be reached soon, allowing such filters to compete favorably with existing Heusler-crystal polarizers at thermal and short neutron wavelengths. It must be stressed that such a system based on a 3 He polarization factory able to feed several passive, transportable, polarizers is well matched to neutron scattering needs. (orig.)

  2. Realization of a broad band neutron spin filter with compressed, polarized 3He gas

    International Nuclear Information System (INIS)

    Surkau, R.; Otten, E.W.; Steiner, M.; Tasset, F.; Trautmann, N.

    1997-01-01

    The strongly spin dependent absorption of neutrons in nuclear spin polarized 3 -2pt vector He opens the possibility to polarize beams of thermal and epithermal neutrons. An effective 3 He neutron spin filter (NSF) requires high 3 He nuclear polarization as well as a filter thickness corresponding to a gas amount of the order of 1 bar l. We realized such a filter using direct optical pumping of metastable 3 He * atoms in a 3 He plasma at 1 mbar. Metastable exchange scattering transfers the angular momentum to the whole ensemble of 3 He atoms. At present 3 x 10 18 3 He-atoms/s are polarized up to 64%. Subsequent polarization preserving compression by a two stage compressor system enables to prepare NSF cells of about 300 cm 3 volume with 3 bar of polarized 3 He within 2 h. 3 He polarizations up to 53% were measured in a cell with a filter length of about 15 cm. By this cell a thermal neutron beam from the Mainz TRIGA reactor was polarized. A wavelength selective polarization analysis by means of Bragg scattering revealed a neutron polarization of 84% at a total transmission of 12% for a neutron wavelength of 1 A. (orig.)

  3. Non-uniform 3He polarization formed by multiple collisions of a fast 3He+ ion with polarized Rb vapor in a strong magnetic field

    International Nuclear Information System (INIS)

    Arimoto, Y.; Yonehara, K.; Yamagata, T.; Tanaka, M.

    2001-01-01

    We investigated the spatial distribution of a polarization in 3 He beam expected from a novel polarized 3 He ion source based on electron pumping, i.e., multiple electron capture and stripping collisions of an incident fast 3 He + ion with a polarized Rb vapor in a strong axial magnetic field. For this purpose, a Monte Carlo simulation was carried out for 19 keV 3 He + ions with varying Rb vapor thickness, magnetic field, and beam emittance. The calculated results showed a distribution of the 3 He polarization that we call a 'polarization hole', which has a low polarization area around the beam axis. The parameters characterizing the polarization hole, i.e., the polarization and radius of the hole, were found to depend on the Rb vapor thickness, the magnetic field, the beam size, and the angular divergence of the initial beam. These parameters were successfully reproduced with analytical functions deduced from a probability density function prescription. This provides a powerful tool to treat complex phenomena of multiple collisions in strong magnetic fields without performing time-consuming Monte Carlo calculations

  4. High-pressure 3He gas scintillation neutron spectrometer

    International Nuclear Information System (INIS)

    Derzon, M.S.; Slaughter, D.R.; Prussin, S.G.

    1985-10-01

    A high-pressure, 3 He-Xe gas scintillation spectrometer has been developed for neutron spectroscopy on D-D fusion plasmas. The spectrometer exhibits an energy resolution of (121 +- 20 keV) keV (FWHM) at 2.5 MeV and an efficiency of (1.9 +- 0.4) x 10 -3 (n/cm 2 ) -1 . The contribution to the resolution (FWHM) from counting statistics is only (22 +- 3 keV) and the remainder is due predominantly to the variation of light collection efficiency with location of neutron events within the active volume of the detector

  5. Neutron beam effects on spin-exchange-polarized 3He.

    Science.gov (United States)

    Sharma, M; Babcock, E; Andersen, K H; Barrón-Palos, L; Becker, M; Boag, S; Chen, W C; Chupp, T E; Danagoulian, A; Gentile, T R; Klein, A; Penttila, S; Petoukhov, A; Soldner, T; Tardiff, E R; Walker, T G; Wilburn, W S

    2008-08-22

    We have observed depolarization effects when high intensity cold neutron beams are incident on alkali-metal spin-exchange-polarized 3He cells used as neutron spin filters. This was first observed as a reduction of the maximum attainable 3He polarization and was attributed to a decrease of alkali-metal polarization, which led us to directly measure alkali-metal polarization and spin relaxation over a range of neutron fluxes at Los Alamos Neutron Science Center and Institute Laue-Langevin. The data reveal a new alkali-metal spin-relaxation mechanism that approximately scales as sqrt[phi_{n}], where phi_{n} is the neutron capture-flux density incident on the cell. This is consistent with an effect proportional to the concentration of electron-ion pairs but is much larger than expected from earlier work.

  6. The scattering of polarized neutrons from statically polarized solid {sup 3}He

    Energy Technology Data Exchange (ETDEWEB)

    Haase, D.G.; Keith, C.D.; Gould, C.R.; Seely, M.L. [North Carolina State Univ., Raleigh, NC (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Huffman, P.R.; Roberson, N.R.; Tornow, W.; Wilburn, W.S. [Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States)]|[Duke University, Durham, NC 27708-0308 (United States)

    1998-01-11

    We have constructed a 0.4 mole solid {sup 3}He target, cryogenically polarized at 12 mK in a field of 7 T. The 0.04 atoms/b target reached a polarization of 38% in 35 h. Such a target may be applied to any experiment which is tolerant of the large ambient magnetic field and which produces target heating of less than a microwatt. High energy neutron and photon scattering experiments meet these requirements. The target`s figure of merit for neutron transmission measurement exceeds that of polarized gas targets by greater than 35. At the Triangle Universities Nuclear Laboratory we have used the target to measure the total cross section differences {Delta}{sigma}{sub T} and {Delta}{sigma}{sub L} for incident polarized neutrons of energies 2-8 MeV. The cross section difference is sensitive to the excited state structure of the n-{sup 3}He system. The results have been compared to a recent R-matrix analysis of A=4 scattering and reaction data, and provide support for the {sup 4}He level scheme derived from that analysis. (orig.). 11 refs.

  7. Results on Double-polarization Asymmetries in Quasielastic Scattering from Polarized 3He

    Directory of Open Access Journals (Sweden)

    Sulkosky Vincent A.

    2016-01-01

    Full Text Available The 3He nucleus has become extremely important in the investigation of the neutron’s spin structure. When polarized, 3He acts as an effective polarized neutron target and hence facilitates our understanding of the neutron’s internal structure. However, to be used in this manner, our understanding of the internal structure of 3He is of extreme importance. As the precision of experiments has improved, the extraction of polarized neutron information from 3He leads to an ever larger share of the systematic uncertainty for these experiments. In these proceedings, I present a precise measurement of beam-target asymmetries in the He→3(e→ ,e′d${}^3\\overrightarrow {He} (\\vec e,e'd$ and He→3(e→,e′p${}^3\\overrightarrow {He} (\\vec e,e'p$ reactions. The former process is a uniquely sensitive probe of hadron dynamics in 3He and the structure of the underlying electromagnetic currents. The measurements have been performed around the quasi-elastic peak at Q2 = 0.25 (GeV/c2 and 0.35 (GeV/c2 for recoil momenta up to 270 MeV/c. The experimental apparatus, analysis and results were presented together with a comparison to state-of-the art Faddeev calculations.

  8. Studies on optical pumping cells (OPC) to polarize 3He

    International Nuclear Information System (INIS)

    Hutanu, V.; Rupp, A.

    2004-01-01

    The technique applied at HMI to obtain nuclear-spin-polarized 3 He, used in neutron spin filters (NSFs), is metastability-exchange optical pumping. To prepare efficient NSF, one must highly polarize 3 He nuclei in the optical pumping volume (OPV) and reduce the polarization losses during the compression phase. Great progress has been achieved in reducing of depolarization due to the recent development of both, large polarization preserving piston compressors and long relaxation time filter cells. It is even more important to significantly enhance the 3 He polarization rate during optical pumping in order to increase NSF efficiency. Different cells materials were tested, such as Duran and quartz glass. In order to use the laser light more efficiently and to decrease the risk of 3 He depolarization due to unfavorable reflections, antireflection (AR) coatings were used on cell windows made of quartz glass. They were compared with the ones without coating, made of quartz, Duran and BK7 glass. The comparison of various techniques to mount the windows such as blowing, gluing or molecular diffusion was also conducted. It indicated that the molecular diffusion is the most suitable technique because of a better purity of the gas in the cell and the preservation of the optical flatness of the windows. Cells, for practical reasons each entirely made from the same material (Duran, Quartz glass) with windows mounted using this method, showed the best polarization performance

  9. The Spin Structure of the Neutron Determined Using a Polarized He-3 Target

    Energy Technology Data Exchange (ETDEWEB)

    Middleton, H

    2004-01-06

    Described is a study of the internal spin structure of the neutron performed by measuring the asymmetry in spin-dependent deep inelastic scattering of polarized electrons from nuclear polarized {sup 3}He. Stanford Linear Accelerator experiment E142's sample of 400 million scattering events collected at beam energies between 19 and 26 GeV led to the most precise measurement of a nucleon spin structure function to date. The {sup 3}He target represents a major advance in polarized target technology, using the technique of spin exchange with optically pumped rubidium vapor to produce a typical {sup 3}He nuclear polarization of 34% in a 30cm long target cell with a gas density of 2.3 x 10{sup 20} cm{sup -3}. The target polarization was measured to {+-}7% using an Adiabatic Fast Passage NMR system calibrated with the thermal equilibrium polarization of the protons in a sample of water. The relatively high polarization and target thickness were the result of the development of large volume glass target cells which had inherent nuclear spin relaxation times for the {sup 3}He gas of as long as 70 hours. A target cell production procedure is presented which focuses on special glass blowing techniques to minimize surface interactions with the {sup 3}He nuclei and careful gas purification and vacuum system procedures to reduce relaxation inducing impurities.

  10. A Precision Measurement of the Neutron Spin Structure Functions Using a Polarized HE-3 Target

    International Nuclear Information System (INIS)

    Smith, T

    2003-01-01

    This thesis describes a precision measurement of the neutron spin dependent structure function, g 1 n (x). The measurement was made by the E154 collaboration at SLAC using a longitudinally polarized, 48.3 GeV electron beam, and a 3 He target polarized by spin exchange with optically pumped rubidium. A target polarization as high as 50% was achieved. The elements of the experiment which pertain to the polarized 3 He target will be described in detail in this thesis. To achieve a precision measurement, it has been necessary to minimize the systematic error from the uncertainty in the target parameters. All of the parameters of the target have been carefully measured, and the most important parameters of the target have been measured using multiple techniques. The polarization of the target was measured using nuclear magnetic resonance techniques, and has been calibrated using both proton NMR and by measuring the shift of the Rb Zeeman resonance frequency due to the 3 He polarization. The fraction of events which originated in the 3 He, as measured by the spectrometers, has been determined using a physical model of the target and the spectrometers. It was also measured during the experiment using a variable pressure 3 He reference cell in place of the polarized 3 He target. The spin dependent structure function g 1 n (z) was measured in the Bjorken x range of 0.014 2 of 5 (GeV/c) 2 . One of the primary motivations for this experiment was to test the Bjorken sum rule. Because the experiment had smaller statistical errors and a broader kinematic coverage than previous experiments, the behavior of the spin structure function g 1 n (x) could be studied in detail at low values of the Bjorken scaling variable x. It was found that g 1 n (x) has a strongly divergent behavior at low values of x, calling into question the methods commonly used to extrapolate the value of g 1 n (x) to low x. The precision of the measurement made by the E154 collaboration at SLAC puts a tighter

  11. A polarized sup 3 He internal target for storage rings

    CERN Document Server

    Poolman, H R; Bulten, H J; Doets, M; Ent, R; Ferro-Luzzi, M; Geurts, D G; Harvey, M; Mul, F A

    2000-01-01

    A polarized sup 3 He internal target was employed at the internal target facility of the Amsterdam electron Pulse Stretcher and Storage ring (AmPS) at the Dutch National Institute for Nuclear and High-Energy Physics (NIKHEF). The unique features of internal targets such as chemical and isotopic purity, high and rapidly reversible polarization, and the ability to manipulate the target spin orientation were successfully demonstrated. A nuclear polarization of 0.50 (0.42) at a sup 3 He gas flow of 1.0 (2.0)x10 sup 1 sup 7 at s sup - sup 1 could be obtained. Operation at a nominal flow of 1x10 sup 1 sup 7 at s sup - sup 1 resulted in a target thickness of 0.7x10 sup 1 sup 5 at cm sup - sup 2 at a target temperature of 17 K.

  12. Progress in Polarized 3He Ion Source at RCNP

    International Nuclear Information System (INIS)

    Tanaka, M.; Takahashi, Y.; Shimoda, T.; Yasui, S.; Yosoi, M.; Takahisa, K.; Shimakura, N.; Plis, Yu. A.; Donets, E. D.

    2007-01-01

    A long history on the polarized 3He ion source developed at RCNP is presented. We started with an 'OPPIS' (Optical Pumping Polarized Ion Source) and later found the fundamental difficulties in the OPPIS. To overcome them an 'EPPIS' (Electron Pumping Polarized Ion Source) was proposed and its validity was experimentally proven. However, a serious technical disadvantage was also found in the EPPIS. To avoid this disadvantage we proposed a new concept, 'SEPIS' (Spin Exchange Polarized Ion Source), which uses an enhanced spin-exchange cross section theoretically expected at low 3He+ incident energies in the 3He+ + Rb system. Next, we describe the present status of the SEPIS development: construction of a bench test device allowing the measurements of not only the spin-exchange cross sections σse but also the electron capture cross sections σec for the 3He+ + Rb system. The latest experimental data on σec are presented and compared with other previous experimental data and the theoretical calculations.Finally, a design study of the SEPIS for practical use in nuclear (cyclotron) and particle physics (synchrotron) is shortly mentioned

  13. A method for the accurate determination of the polarization of a neutron beam using a polarized 3He spin filter

    International Nuclear Information System (INIS)

    Greene, G.L.; Thompson, A.K.; Dewey, M.S.

    1995-01-01

    A new method for the accurate determination of the degree of polarization of a neutron beam which has been polarized by transmission through a spin polarized 3 He cell is given. The method does not require the use of an analyzer or spin flipper nor does it require an accurate independent determination of the 3 He polarization. The method provides a continuous on-line determination of the neutron polarization. The method may be of use in the accurate determination of correlation coefficients in neutron beta decay which provide a test of the standard model for the electroweak interaction. The method may also provide an accurate procedure for the calibration of polarized 3 He targets used in medium and high energy scattering experiments. ((orig.))

  14. A polarized solid {sup 3}He target for neutron transmission experiments

    Energy Technology Data Exchange (ETDEWEB)

    Keith, C.D. [North Carolina State Univ., Raleigh, NC (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Gould, C.R. [North Carolina State Univ., Raleigh, NC (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Haase, D.G. [North Carolina State Univ., Raleigh, NC (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Huffman, P.R. [Duke University, Durham, NC 27708-0308 (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Roberson, N.R. [Duke University, Durham, NC 27708-0308 (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Seely, M.L. [North Carolina State Univ., Raleigh, NC (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Tornow, W. [Duke University, Durham, NC 27708-0308 (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Wilburn, W.S. [Duke University, Durham, NC 27708-0308 (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States)

    1995-04-01

    We describe the construction and operation of a solid {sup 3}He polarized nuclear target which we have used for measurements of the spin dependence of the n-{sup 3}He interaction at MeV energies. The target, which contains 0.4 mole of {sup 3}He was polarized to 38% at 12 mK in a field of 7 T. The target is suitable for nuclear physics measurements which are insensitive to the large magnetic field and produce beam heating of tenths of microwatts.We discuss refinements and paths to improved solid {sup 3}He targets at higher polarizations and lower fields. ((orig.)).

  15. In situ polarized 3He system for the Magnetism Reflectometer at the Spallation Neutron Source.

    Science.gov (United States)

    Tong, X; Jiang, C Y; Lauter, V; Ambaye, H; Brown, D; Crow, L; Gentile, T R; Goyette, R; Lee, W T; Parizzi, A; Robertson, J L

    2012-07-01

    We report on the in situ polarized (3)He neutron polarization analyzer developed for the time-of-flight Magnetism Reflectometer at the Spallation Neutron Source at Oak Ridge National Laboratory. Using the spin exchange optical pumping method, we achieved a (3)He polarization of 76% ± 1% and maintained it for the entire three-day duration of the test experiment. Based on transmission measurements with unpolarized neutrons, we show that the average analyzing efficiency of the (3)He system is 98% for the neutron wavelength band of 2-5 Å. Using a highly polarized incident neutron beam produced by a supermirror bender polarizer, we obtained a flipping ratio of >100 with a transmission of 25% for polarized neutrons, averaged over the wavelength band of 2-5 Å. After the cell was depolarized for transmission measurements, it was reproducibly polarized and this performance was maintained for three weeks. A high quality polarization analysis experiment was performed on a reference sample of Fe/Cr multilayer with strong spin-flip off-specular scattering. Using a combination of the position sensitive detector, time-of-flight method, and the excellent parameters of the (3)He cell, the polarization analysis of the two-dimensional maps of reflected, refracted, and off-specular scattered intensity above and below the horizon were obtained, simultaneously.

  16. A Precision Measurement of the Neutron Spin Structure Functions Using a Polarized HE-3 Target

    Energy Technology Data Exchange (ETDEWEB)

    Smith, T

    2003-11-05

    This thesis describes a precision measurement of the neutron spin dependent structure function, g{sub 1}{sup n}(x). The measurement was made by the E154 collaboration at SLAC using a longitudinally polarized, 48.3 GeV electron beam, and a {sup 3}He target polarized by spin exchange with optically pumped rubidium. A target polarization as high as 50% was achieved. The elements of the experiment which pertain to the polarized {sup 3}He target will be described in detail in this thesis. To achieve a precision measurement, it has been necessary to minimize the systematic error from the uncertainty in the target parameters. All of the parameters of the target have been carefully measured, and the most important parameters of the target have been measured using multiple techniques. The polarization of the target was measured using nuclear magnetic resonance techniques, and has been calibrated using both proton NMR and by measuring the shift of the Rb Zeeman resonance frequency due to the {sup 3}He polarization. The fraction of events which originated in the {sup 3}He, as measured by the spectrometers, has been determined using a physical model of the target and the spectrometers. It was also measured during the experiment using a variable pressure {sup 3}He reference cell in place of the polarized {sup 3}He target. The spin dependent structure function g{sub 1}{sup n}(z) was measured in the Bjorken x range of 0.014 < x < 0.7 with an average Q{sup 2} of 5 (GeV/c){sup 2}. One of the primary motivations for this experiment was to test the Bjorken sum rule. Because the experiment had smaller statistical errors and a broader kinematic coverage than previous experiments, the behavior of the spin structure function g{sub 1}{sup n}(x) could be studied in detail at low values of the Bjorken scaling variable x. It was found that g{sub 1}{sup n}(x) has a strongly divergent behavior at low values of x, calling into question the methods commonly used to extrapolate the value of g

  17. π--induced single charge exchange on polarized 3He

    International Nuclear Information System (INIS)

    Zhao, Q.; Burleson, S.; Blanchard, T.

    1995-01-01

    Asymmetries, A y , for the (π - ,π 0 ) reaction on polarized 3 He were measured using the pion beam of the P3W channel at LAMPF. The π 0 were detected with the new Neutral Meson Spectrometer (NMS) in coincidence with recoiling tritons. The recoil detector consisted of scintillation-counter telescopes and a wire chamber that provided energy-loss and direction information, respectively. The polarized gaseous 3 He target developed at TRIUMF was modified and run with the use of two diode lasers. Polarizations were typically 50%. The A y taken at T π = 200 MeV between 60 and 105 degrees were found to be strongly angle-dependent. The results will be compared with the theoretical predictions

  18. Spin exchange optical pumping based polarized 3He filling station for the Hybrid Spectrometer at the Spallation Neutron Source.

    Science.gov (United States)

    Jiang, C Y; Tong, X; Brown, D R; Culbertson, H; Graves-Brook, M K; Hagen, M E; Kadron, B; Lee, W T; Robertson, J L; Winn, B

    2013-06-01

    The Hybrid Spectrometer (HYSPEC) is a new direct geometry spectrometer at the Spallation Neutron Source at the Oak Ridge National Laboratory. This instrument is equipped with polarization analysis capability with 60° horizontal and 15° vertical detector coverages. In order to provide wide angle polarization analysis for this instrument, we have designed and built a novel polarized (3)He filling station based on the spin exchange optical pumping method. It is designed to supply polarized (3)He gas to HYSPEC as a neutron polarization analyzer. In addition, the station can optimize the (3)He pressure with respect to the scattered neutron energies. The depolarized (3)He gas in the analyzer can be transferred back to the station to be repolarized. We have constructed the prototype filling station. Preliminary tests have been carried out demonstrating the feasibility of the filling station. Here, we report on the design, construction, and the preliminary results of the prototype filling station.

  19. Laser - Polarized HE-3 Target Used for a Precision Measurement of the Neutron Spin Structure

    Energy Technology Data Exchange (ETDEWEB)

    Romalis, M

    2003-11-05

    This thesis describes a precision measurement of the deep inelastic neutron spin structure function g{sub 1}{sup n}(x). The main motivation for the experiment is a test of the Bjorken sum rule. Because of smaller statistical errors and broader kinematic coverage than in previous experiments, we are able to study in detail the behavior of the spin structure function g{sub 1}{sup n}(x) for low values of the Bjorken scaling variable x. We find that it has a strongly divergent behavior, in contradiction to the naive predictions of the Regge theory. This calls into question the methods commonly used for extrapolation of g{sub 1}{sup n}(x) to x = 0. The difference between the proton and the neutron spin structure functions is less divergent at low x, so a test of the Bjorken sum rule is possible. We confirm the sum rule with an accuracy of 8%. The experiment was performed at SLAC using a 50 GeV polarized electron beam and a polarized {sup 3}He target. In this thesis the polarized target is described in detail. We used the technique of Rb optical pumping and Rb-He spin exchange to polarize the {sup 3}He. Because of a novel mechanical design our target had the smallest dilution ever achieved for a high density gas target. Since this is a precision measurement, particular efforts were made to reduce the systematic errors due to the uncertainty in the target parameters. Most important parameters were measured by more than one method. We implemented novel techniques for measuring the thickness of the glass windows of the target, the {sup 3}He density, and the polarization. In particular, one of the methods for measuring the gas density relied on the broadening of the Rb optical absorption lines by collisions with {sup 3}He atoms. The calibration of this technique resulted in the most precise measurements of the pressure broadening parameters for {sup 3}He as well as several other gases, which are described in an Appendix. The polarization of the {sup 3}He was also measured by

  20. Polarized 3He Neutron Spin Filters

    Energy Technology Data Exchange (ETDEWEB)

    Sno, William Michael [Indiana Univ., Bloomington, IN (United States)

    2016-01-12

    The goal of this grant to Indiana University and subcontractors at Hamilton College and Wisconsin and the associated Interagency Agreement with NIST was to extend the technique of polarized neutron scattering by the development and application of polarized 3He-based neutron spin filters. This effort was blessed with long-term support from the DOE Office of Science, which started in 2003 and continued until the end of a final no-cost extension of the last 3-year period of support in 2013. The steady support from the DOE Office of Science for this long-term development project was essential to its eventual success. Further 3He neutron spin filter development is now sited at NIST and ORNL.

  1. Study of mechanical compression of spin-polarized 3He gas

    International Nuclear Information System (INIS)

    Becker, J.; Heil, W.; Krug, B.; Leduc, M.; Meyerhoff, M.; Nacher, P.J.; Otten, E.W.; Prokscha, T.; Schearer, L.D.; Surkau, R.

    1994-01-01

    We have piloted mechanical compression of spinpolarized 3He by a titanium piston compressor. Questions of materials and design are discussed, followed by a thorough investigation of relaxation sources in the course of compression. The latter are traced mainly to regions with large surface to volume ratio, through which fast passage is demanded, therefore. We conclude from this feasibility study that polarized 3He may be compressed this way up to many bars without serious polarization losses. ((orig.))

  2. POLARIZED-LIGHT EMISSION IN KEV HE2++NA(3S) COLLISIONS

    NARCIS (Netherlands)

    BODUCH, P; VANBUCHEM, J; BLIEK, FW; HOEKSTRA, R; MORGENSTERN, R; OLSON, RE

    1995-01-01

    We investigated l and m-distributions of He II (n = 4) states formed during 2-13.3 keV amu(-1) He2+ + Na(3s) collisions by measuring profiles and the linear polarization of the He II (4 --> 3) emission. We found that at these energies capture into He+(4f) dominates over capture into other He+(4l)

  3. Analyzing Power of 3He(n, n)3He Between 1.60 and 5.54 MeV

    International Nuclear Information System (INIS)

    Esterline, J.; Tornow, W.

    2013-01-01

    We report the measurements of the analyzing power A y (θ) of n- 3 He elastic scattering with unprecedented accuracy and angular coverage at five incident neutron energies between 1.60 and 5.54 MeV. To this end, we employed the polarization-transfer reactions 3 H(p, n) 3 He and 2 H(d, n) 3 He at 0 ° for neutron generation and a recently developed high-pressure 3 He gas scintillator as an active target, enabling neutron-time-of-flight and 3 He recoil-energy determinations. We obtained simultaneously the neutron polarization with a 4 He-based polarimeter, capitalizing on the well-known n- 4 He A y (θ). Our n- 3 He A y (θ) data are compared to rigorous four-nucleon calculations using high-precision nucleon–nucleon potential models. The agreement between data and calculations is fair at the lower energies and becomes less satisfactory with increasing neutron energy. However, in comparison to the pure isotriplet p- 3 He system in the same energy region, the agreement between measured and calculated A y is much better for the mixed (isotriplet and isosinglet) n- 3 He system, indicating large and somewhat counterintuitive isospin effects. We note that the incorporation of a Δ-mediated three-nucleon force in calculations of n- 3 He scattering was found to affect A y (θ) negligibly, suggesting the need for the reconsideration of fundamental interactions in resolving the four-nucleon analyzing power puzzle first established about a decade ago in p- 3 He scattering. (author)

  4. Spin-polarized 3He nuclear targets and metastable 4He atoms by optical pumping with a tunable, Nd:YAP laser

    International Nuclear Information System (INIS)

    Bohler, C.L.; Schearer, L.D.; Leduc, M.; Nacher, P.J.; Zachorowski, L.; Milner, R.G.; McKeown, R.D.; Woodward, C.E.

    1988-01-01

    Several Nd:YAP lasers were constructed which could be broadly tuned in the 1083-nm region which includes the helium 2 3 S-2 3 P transition, using a Lyot filter and thin, uncoated etalons within the laser cavity. 1 W of power could be extracted at 1083 nm through a 1% transmitting output coupler. This laser beam was used to optically pump metastable 4 He and 3 He 2 3 S helium atoms in a weak discharge cell, spin polarizing the metastable ensemble. In a 3 He cell the polarization is transferred to the nuclear spin system. A 3 He target cell at 0.3 Torr was polarized to 52% in a few minutes. We describe the application of this system to the design of polarized targets for experiments in nuclear physics

  5. Recent advancements of wide-angle polarization analysis with 3He neutron spin filters

    International Nuclear Information System (INIS)

    Chen, W.C.; Gentile, T.R.; Ye, Q.; Kirchhoff, A.; Watson, S.M.; Rodriguez-Rivera, J.A.; Qiu, Y.; Broholm, C.

    2016-01-01

    Wide-angle polarization analysis with polarized 3 He based neutron spin filters (NSFs) has recently been employed on the Multi-Axis Crystal Spectrometer (MACS) at the National Institute of Standards and Technology Center for Neutron Research (NCNR). Over the past several years, the apparatus has undergone many upgrades to address the fundamental requirements for wide angle polarization analysis using spin exchange optical pumping based 3 He NSFs. In this paper, we report substantial improvements in the on-beam-line performance of the apparatus and progress toward routine user capability. We discuss new standard samples used for 3 He NSF characterization and the flipping ratio measurement on MACS. We further discuss the management of stray magnetic fields produced by operation of superconducting magnets on the MACS instrument, which can significantly reduce the 3 He polarization relaxation time. Finally, we present the results of recent development of horseshoe-shaped wide angle cells. (paper)

  6. Spin-polarized electron capture for the Na+3He2+ system at a 3He2+ impact energy of 5.33--9.33 keV/amu

    International Nuclear Information System (INIS)

    Tanaka, M.; Shimakura, N.; Ohshima, T.; Katori, K.; Fujiwara, M.; Ogata, H.; Kondo, M.

    1994-01-01

    3 He + atomic polarizations following the spin-polarized electron capture process for the N rvec a(3s)+ 3 He 2+ system were measured at 3 He 2+ impact energies from 5.33 to 9.33 keV/amu. The magnitude of the 3 He + atomic polarizations was deduced from the 3 He + nuclear polarization measured by means of beam-foil spectroscopy. The observed polarization transfer coefficient P T defined by the ratio of the 3 He + atomic polarization to the sodium one showed a pronounced reduction from unity, which was qualitatively explained by the prediction of a simple cascade photon decay model. Evidence for a further reduction of P T from the above model and a possible impact energy dependence of P T suggested an excessive depolarization due to the presence of the collision alignment parameter A 0 col of 3 He + formed by the electron capture process. In order to see this more closely, the observed P T 's were examined theoretically using the semiclassical impact parameter method, in which an 18-state molecular expansion was employed, and atomic-type electron translation effects were rigorously taken into account. Ensuring that both the absolute values and the impact energy dependence of the observed capture cross sections were remarkably well reproduced by the calculations in which the states up to 4f in 3 He + were introduced, it was demonstrated that the calculated results for P T qualitatively reproduced not only the absolute values of the observed P T 's but also their gentle decrease with increasing impact energy. Production of nuclear polarizations resulting from the polarized electron capture processes between multicharged heavy ions and alkaline-earth-metal atoms is an example of one use of the future project of universal polarized heavy-ion sources

  7. The osmotic pressure of 3He-4He mixtures along the phase separation curve

    NARCIS (Netherlands)

    van de Klundert, L.J.M.; Bos, M.R.E.; van der Meij, J.A.M.; Steffens, H.A.

    1977-01-01

    The osmotic pressure of 3He-4He mixtures was measured along the phase separation curve at temperatures up to 500 mK by balancing it with the fountain pressure of pure 4He. The usefullness of the secondary osmotic pressure thermometer was reinvestigated.

  8. The osmotic pressure of 3He-4He mixtures along the phase separation curve

    International Nuclear Information System (INIS)

    Klundert, L.J.M. van de; Bos, M.R.E.; Meij, J.A.M. van der; Steffens, H.A.

    1977-01-01

    The osmotic pressure of 3 He- 4 He mixtures was measured along the phase separation curve at temperatures up to 500 mK by balancing it with the fountain pressure of pure 4 He. The usefullness of the secondary osmotic pressure thermometer was reinvestigated. (Auth.)

  9. Low level neutron monitoring using high pressure 3He detectors

    International Nuclear Information System (INIS)

    Pszona, S.

    1995-01-01

    Three detectors, two spherical proportional counters and an ionisation chamber, all filled with 3 He to pressures of 160 kPa, 325 kPa and 1 MPa respectively have been experimentally studied with respect to their use for low level neutron monitoring. The ambient dose equivalent responses and the energy resolutions of these detectors have been determined. It is shown that spectral analysis of the signals from these detectors not only gives high sensitivity with regard to ambient dose equivalent but also improves the quality of the measurements. A special instrumentation for low level neutron monitoring is described in which a quality control method has been implemented. (Author)

  10. Effect of spin-polarized D-3He fuel on dense plasma focus for space propulsion

    Science.gov (United States)

    Mei-Yu Wang, Choi, Chan K.; Mead, Franklin B.

    1992-01-01

    Spin-polarized D-3He fusion fuel is analyzed to study its effect on the dense plasma focus (DPF) device for space propulsion. The Mather-type plasma focus device is adopted because of the ``axial'' acceleration of the current carrying plasma sheath, like a coaxial plasma gun. The D-3He fuel is chosen based on the neutron-lean fusion reactions with high charged-particle fusion products. Impulsive mode of operation is used with multi-thrusters in order to make higher thrust (F)-to-weight (W) ratio with relatively high value of specific impulse (Isp). Both current (I) scalings with I2 and I8/3 are considered for plasma pinch temperature and capacitor mass. For a 30-day Mars mission, with four thrusters, for example, the typical F/W values ranging from 0.5-0.6 to 0.1-0.2 for I2 and I8/3 scalings, respectively, and the Isp values of above 1600 s are obtained. Parametric studies indicate that the spin-polarized D-3He provides increased values of F/W and Isp over conventional D-3He fuel which was due to the increased fusion power and decreased radiation losses for the spin-polarized case.

  11. Polarization transfer in the 3H(rvec p,rvec n)3He reaction and the 0- level in 4He

    International Nuclear Information System (INIS)

    Walston, J.R.; Gould, C.R.; Haase, D.G.; Raichle, B.W.; Seely, M.L.; Walston, J.R.; Keith, C.D.; Gould, C.R.; Haase, D.G.; Raichle, B.W.; Seely, M.L.; Tornow, W.; Wilburn, W.S.; Keith, C.D.; Tornow, W.; Wilburn, W.S.; Hoffmann, G.W.; Penttilae, S.I.

    1998-01-01

    Longitudinal polarization-transfer coefficients for the 3 H(rvec p,rvec n) 3 He reaction have been measured at zero degrees for proton energies of 1.3 endash 2.8 MeV. The results show a striking resonance behavior for energies corresponding to excitation of the 0 - level in 4 He at 21.0 MeV. In agreement with R-matrix calculations, the value approaches unity at 1.52 MeV, the peak of the resonance. Near this same energy, at 1.62 MeV, the transverse polarization-transfer coefficient was measured to be consistent with zero. copyright 1998 The American Physical Society

  12. Study of the nuclear structure of 3He by means of polarization observables

    International Nuclear Information System (INIS)

    Weinriefer, Markus

    2011-01-01

    With the possibility to measure several polarization degrees of freedom in the quasi-elastic electron scattering of 3 He is a new way to access small, but important partial wave contributions (S ' , D-wave) to the 3 He ground state. This gives direct access to a better understanding of the three-body-system. It also opens up a way to directly test the 3 He structure and dynamics. With this information it is possible to test ab initio calculations and to calculate corrections that are needed for different experiments (measurement of G en for example). Modern Faddeev-calculations do not only give a quantitative description of the 3 He ground state. They also give insight in so called spin dependent momentum distributions. A systematic experimental investigation is needed to get a good basis for tests of the theoretical models. A triple-polarization-experiment can give important data in this field. Also with the help of such an experiment one can investigate if polarized 3 He can be used as an effective polarized proton target by the method of ''deuteron-tagging''. The experiment presented in this work combines for the first time beam- and target-polarization as well as a measurement of the polarization of the outgoing proton. The measurement was done in summer of 2007 at the three spectrometer setup of the A1 collaboration at the MAMI accelerator. A beam energy of E=855 MeV was used and we measured at q 2 =-0.14 (GeV/c) 2 (ω=0.13 GeV, q=0.4 GeV/c). The measured cross section, as well as the beam-target- and triple-asymmetry were compared to a theoretical calculation by J. Golak (he gives a plane wave impulse approximation (PWIA) calculation and a calculation also taking final state interaction into account). The cross section was also compared to a model by de Forest that is using a measured spectral function. The comparison shows a good agreement between the measured cross section as well as the double and triple asymmetry and the theoretical calculations. The

  13. Towards polarization measurements of laser-accelerated helium-3 ions

    Energy Technology Data Exchange (ETDEWEB)

    Engin, Ilhan

    2015-08-28

    In the framework of this thesis, preparatory investigations for the spin-polarization measurement of {sup 3}He ions from laser-induced plasmas have been performed. Therefore, experiments aiming at an efficient laser-induced ion acceleration out of a {sup 4}He gas target were carried out at two high-intensity laser facilities: the Arcturus laser at Heinrich-Heine-Universitaet Duesseldorf as well as PHELIX at GSI Darmstadt. The scientific goal of both experiments was to investigate the ion-acceleration process in underdense plasmas by measuring the ion energy spectra and the angular distribution of the ion signal around the gas-jet target. Laser-accelerated MeV-He-ions could successfully be detected. The main acceleration direction at large angles with regard to the laser propagation direction was determined. In a second step, unpolarized {sup 3}He gas was attached in order to cross-check the experimental results with those of {sup 4}He. With the help of the achieved ion yield data, the expected rates of the fusion reaction D({sup 3}He,p){sup 4}He in the polarized case have been estimated: the information regarding the fusion proton yield from this nuclear reaction allows an experimentally based estimation for future experiments with pre-polarized {sup 3}He gas as plasma target. The experimental data is in line with supporting Particle-in-Cell (PIC) simulations performed on the Juelich supercomputers. For this purpose, the simulated target was defined as a neutral gas. The use of pre-polarized {sup 3}He gas demands a special preparation of a polarized {sup 3}He target for laser-acceleration experiments. This layout includes an (external) homogeneous magnetic holding field (field strength of ∝1.4 mT) for storing the pre-polarized gas for long time durations inside the PHELIX target chamber. For this purpose, a precise Halbach array consisting of horizontally arranged rings with built-in permanent magnets had to be designed, optimized, and constructed to deliver high

  14. Polarization Observables for the Collinear dp → 3 Heπ0 Reaction

    International Nuclear Information System (INIS)

    Ladygin, V.P.; Ladygina, N.B.

    1994-01-01

    Effects due to polarizations of both colliding particles have been analyzed in terms of two independent amplitudes which in the general case define the spin structure of the amplitude of the dp → 3 Heπ 0 reaction in collinear geometry. The energy dependence of spin-correlation C L , L , O , O due to longitudinal polarization of colliding particles is predicted using the moduli of amplitudes extracted from experimental data. The limit of possible deviations is obtained for spin-correlation C N , N , O , O due to transverse polarization of both particles. The value of these polarization observables at threshold are predicted. The behaviour of these polarization observables for the dp → 3 Heη 0 reaction, having the same spin structure, is discussed. 22 refs., 5 figs., 2 tabs

  15. Increasing the pump-up rate to polarize 3He gas using spin-exchange optical pumping method

    International Nuclear Information System (INIS)

    Lee, W.T.; Tong Xin; Rich, Dennis; Liu Yun; Fleenor, Michael; Ismaili, Akbar; Pierce, Joshua; Hagen, Mark; Dadras, Jonny; Robertson, J. Lee

    2009-01-01

    In recent years, polarized 3 He gas has increasingly been used as neutron polarizers and polarization analyzers. Two of the leading methods to polarize the 3 He gas are the spin-exchange optical pumping (SEOP) method and the meta-stable exchange optical pumping (MEOP) method. At present, the SEOP setup is comparatively compact due to the fact that it does not require the sophisticated compressor system used in the MEOP method. The temperature and the laser power available determine the speed, at which the SEOP method polarizes the 3 He gas. For the quantity of gas typically used in neutron scattering work, this speed is independent of the quantity of the gas required, whereas the polarizing time using the MEOP method is proportional to the quantity of gas required. Currently, using the SEOP method to polarize several bar-liters of 3 He to 70% polarization would require 20-40 h. This is an order of magnitude longer than the MEOP method for the same quantity of gas and polarization. It would therefore be advantageous to speed up the SEOP process. In this article, we analyze the requirements for temperature, laser power, and the type of alkali used in order to shorten the time required to polarize 3 He gas using the SEOP method.

  16. The scattering of polarized deuterons on 3He between 10 and 17 MeV

    International Nuclear Information System (INIS)

    Ohlsen, G.G.; Jarmie, N.; Haglund, R.H. Jr.; Brown, R.E.; Schmelzbach, P.A.

    1978-01-01

    Using the LASL polarized beam facility, the cross section and vector and tensor analysing powers for the 3 He(d vector,d) 3 He and 3 He(d vector,p) 4 He reactions have been measured in a large angular range at energies between 10 and 17 MeV. (orig./WL) [de

  17. Second sound, osmotic pressure, and Fermi-liquid parameters in 3He-4He solutions

    International Nuclear Information System (INIS)

    Corruccini, L.R.

    1984-01-01

    Second-sound velocities and osmotic pressures are analyzed to obtain the first experimental values for the Landau compressibility parameter F 0 /sup s/ in 3 He- 4 He solutions. Data are presented as a function of pressure and 3 He concentration, and are compared to theoretical predictions. The square of the second-sound velocity at finite temperature is found to be accurately proportional to the internal energy of a perfect Fermi gas. Using inertial effective masses given by the Landau-Pomeranchuk theory, the square of the velocity is found to separate into two parts: a temperature-dependent part characterized completely by ideal Fermi-gas behavior and a temperature-independent part containing all the Fermi-liquid corrections. This is related to a similar separation found in the osmotic pressure

  18. A polarized {sup 3}He target for the photon beam at MAMI

    Energy Technology Data Exchange (ETDEWEB)

    Krimmer, J., E-mail: j.krimmer@ipnl.in2p3.fr [Institut fuer Physik, Johannes Gutenberg-Universitaet, Staudinger Weg 7, 55099 Mainz (Germany); Institut de Physique Nucleaire de Lyon, 4 rue Enrico Fermi, 69622 Villeurbanne cedex (France); Aguar Bartolome, P.; Ahrens, J. [Institut fuer Kernphysik, Johannes Gutenberg-Universitaet, Johann-Joachim-Becher-Weg 45, 55099 Mainz (Germany); Altieri, S. [INFN Sezione di Pavia, Pavia (Italy); Dipartimento di Fisica Nucleare e Teorica, Universita di Pavia, Pavia (Italy); Arends, H.J. [Institut fuer Kernphysik, Johannes Gutenberg-Universitaet, Johann-Joachim-Becher-Weg 45, 55099 Mainz (Germany); Heil, W.; Karpuk, S.; Otten, E.W. [Institut fuer Physik, Johannes Gutenberg-Universitaet, Staudinger Weg 7, 55099 Mainz (Germany); Pedroni, P. [INFN Sezione di Pavia, Pavia (Italy); Salhi, Z. [Institut fuer Physik, Johannes Gutenberg-Universitaet, Staudinger Weg 7, 55099 Mainz (Germany); Thomas, A. [Institut fuer Kernphysik, Johannes Gutenberg-Universitaet, Johann-Joachim-Becher-Weg 45, 55099 Mainz (Germany)

    2011-08-21

    A polarized {sup 3}He target has been installed for the first time inside the 4{pi} Crystal Ball detector at the tagged photon beam of the MAinz MIcrotron (MAMI). It has been demonstrated that the system works reliably and that the polarization losses during handling of the polarized gas are under control. Initial polarization values up to 70% and total relaxation times up to 20 h could be obtained during a first test beam time devoted to the measurement of the double polarized photoabsorption cross-section in the {Delta}(1232) baryon resonance region.

  19. Determination of the spin polarization of a 4He+ ion beam

    International Nuclear Information System (INIS)

    Suzuki, T.; Yamauchi, Y.

    2008-01-01

    It was demonstrated that the spin polarization of a 4 He + ion beam (P He + ) can be determined from the spin dependence of the electron emission in the deexcitation process of spin-polarized He metastable atoms (He*, 2 3 S 1 ) and spin-polarized He + ions on Fe (100) surfaces. On Fe (100) surfaces, both He* and He + deexcite via Auger neutralization, and therefore, the spin asymmetry obtained from spin-polarized He + ion neutralization spectroscopy should be equal to that from spin-polarized metastable He* deexcitation spectroscopy. The spin polarization of He* was obtained from Stern-Gerlach measurements. P He + was finally determined to be 0.19±0.02

  20. Development of a compact in situ polarized 3He neutron spin filter at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Jiang, C. Y.; Tong, X.; Brown, D. R.; Kadron, B. J.; Robertson, J. L.; Chi, S.; Christianson, A. D.; Winn, B. L.

    2014-01-01

    We constructed a compact in situ polarized 3 He neutron spin filter based on spin-exchange optical pumping which is capable of continuous pumping of the 3 He gas while the system is in place in the neutron beam on an instrument. The compact size and light weight of the system simplifies its utilization on various neutron instruments. The system has been successfully tested as a neutron polarizer on the triple-axis spectrometer (HB3) and the hybrid spectrometer (HYSPEC) at Oak Ridge National Laboratory. Over 70% 3 He polarization was achieved and maintained during the test experiments. Over 90% neutron polarization and an average of 25% transmission for neutrons of 14.7 meV and 15 meV was also obtained

  1. High-pressure 3He-Xe gas scintillators for simultaneous detection of neutrons and gamma rays over a large energy range

    International Nuclear Information System (INIS)

    Tornow, W.; Esterline, J.H.; Leckey, C.A.; Weisel, G.J.

    2011-01-01

    We report on features of high-pressure 3 He-Xe gas scintillators which have not been sufficiently addressed in the past. Such gas scintillators can be used not only for the efficient detection of low-energy neutrons but at the same time for the detection and identification of γ-rays as well. Furthermore, 3 He-Xe gas scintillators are also very convenient detectors for fast neutrons in the 1-10 MeV energy range and for high-energy γ-rays in the 7-15 MeV energy range. Due to their linear pulse-height response and self calibration via the 3 He(n,p) 3 H reaction, neutron and γ-ray energies can easily be determined in this high-energy regime.

  2. Setup for polarized neutron imaging using in situ 3He cells at the Oak Ridge National Laboratory High Flux Isotope Reactor CG-1D beamline.

    Science.gov (United States)

    Dhiman, I; Ziesche, Ralf; Wang, Tianhao; Bilheux, Hassina; Santodonato, Lou; Tong, X; Jiang, C Y; Manke, Ingo; Treimer, Wolfgang; Chatterji, Tapan; Kardjilov, Nikolay

    2017-09-01

    In the present study, we report a new setup for polarized neutron imaging at the ORNL High Flux Isotope Reactor CG-1D beamline using an in situ 3 He polarizer and analyzer. This development is very important for extending the capabilities of the imaging instrument at ORNL providing a polarized beam with a large field-of-view, which can be further used in combination with optical devices like Wolter optics, focusing guides, or other lenses for the development of microscope arrangement. Such a setup can be of advantage for the existing and future imaging beamlines at the pulsed neutron sources. The first proof-of-concept experiment is performed to study the ferromagnetic phase transition in the Fe 3 Pt sample. We also demonstrate that the polychromatic neutron beam in combination with in situ 3 He cells can be used as the initial step for the rapid measurement and qualitative analysis of radiographs.

  3. High-pressure {sup 3}He-Xe gas scintillators for simultaneous detection of neutrons and gamma rays over a large energy range

    Energy Technology Data Exchange (ETDEWEB)

    Tornow, W., E-mail: tornow@tunl.duke.edu [Department of Physics, Duke University, Durham, NC 27708 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Esterline, J.H. [Department of Physics, Duke University, Durham, NC 27708 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Leckey, C.A. [Department of Physics, The College of William and Mary, Williamsburg, VA 23187 (United States); Weisel, G.J. [Department of Physics, Penn State Altoona, Altoona, PA 16601 (United States)

    2011-08-11

    We report on features of high-pressure {sup 3}He-Xe gas scintillators which have not been sufficiently addressed in the past. Such gas scintillators can be used not only for the efficient detection of low-energy neutrons but at the same time for the detection and identification of {gamma}-rays as well. Furthermore, {sup 3}He-Xe gas scintillators are also very convenient detectors for fast neutrons in the 1-10 MeV energy range and for high-energy {gamma}-rays in the 7-15 MeV energy range. Due to their linear pulse-height response and self calibration via the {sup 3}He(n,p){sup 3}H reaction, neutron and {gamma}-ray energies can easily be determined in this high-energy regime.

  4. Intermediate energy charge-exchange reactions induced by polarized 3He

    International Nuclear Information System (INIS)

    Kim, B.T.

    1998-01-01

    Spin polarization transfer is proven to be very useful in obtaining detailed information of the continuum nuclear responses. The data, taken for the (vector p,vector n) reactions, have enabled us to separate the response into the spin longitudinal and transverse components. These partial nuclear responses have been successfully used to make critical tests of nuclear structure models. In the present paper, we first summarize the results of the data and the theoretical analyses made so far. We then discuss information obtainable from the ( 3 vector He,vector t) reaction, emphasizing on the differences and similarities in comparison with the (vector p,vector n) reaction. The results of numerical calculations made for ( 3 vector He,vector t) reactions based on the microscopic distorted wave impulse approximation will also be reported. (orig.)

  5. Development of a 3He nuclear spin flip system on an in-situ SEOP 3He spin filter and demonstration for a neutron reflectometer and magnetic imaging technique

    International Nuclear Information System (INIS)

    Hayashida, H; Kira, H; Miyata, N; Akutsu, K; Mizusawa, M; Parker, J D; Matsumoto, Y; Oku, T; Sakai, K; Hiroi, K; Shinohara, T; Takeda, M; Yamazaki, D; Oikawa, K; Harada, M; Ino, T; Imagawa, T; Ohkawara, M; Ohoyama, K; Kakurai, K

    2016-01-01

    We have been developing a 3 He neutron spin filter (NSF) using the spin exchange optical pumping (SEOP) technique. The 3 He NSF provides a high-energy polarized neutron beam with large beam size. Moreover the 3 He NSF can work as a π-flipper for a polarized neutron beam by flipping the 3 He nuclear spin using a nuclear magnetic resonance (NMR) technique. For NMR with the in-situ SEOP technique, the polarization of the laser must be reversed simultaneously because a non-reversed laser reduces the polarization of the spin-flipped 3 He. To change the polarity of the laser, a half-wavelength plate was installed. The rotation angle of the half-wavelength plate was optimized, and a polarization of 97% was obtained for the circularly polarized laser. The 3 He polarization reached 70% and was stable over one week. A demonstration of the 3 He nuclear spin flip system was performed at the polarized neutron reflectometer SHARAKU (BL17) and NOBORU (BL10) at J-PARC. Off-specular measurement from a magnetic Fe/Cr thin film and magnetic imaging of a magnetic steel sheet were performed at BL17 and BL10, respectively. (paper)

  6. A measurement of the absolute neutron beam polarization produced by an optically pumped 3He neutron spin filter

    International Nuclear Information System (INIS)

    Rich, D.R.; Bowman, J.D.; Crawford, B.E.; Delheij, P.P.J.; Espy, M.A.; Haseyama, T.; Jones, G.; Keith, C.D.; Knudson, J.; Leuschner, M.B.; Masaike, A.; Masuda, Y.; Matsuda, Y.; Penttilae, S.I.; Pomeroy, V.R.; Smith, D.A.; Snow, W.M.; Szymanski, J.J.; Stephenson, S.L.; Thompson, A.K.; Yuan, V.

    2002-01-01

    The capability of performing accurate absolute measurements of neutron beam polarization opens a number of exciting opportunities in fundamental neutron physics and in neutron scattering. At the LANSCE pulsed neutron source we have measured the neutron beam polarization with an absolute accuracy of 0.3% in the neutron energy range from 40 meV to 10 eV using an optically pumped polarized 3 He spin filter and a relative transmission measurement technique. 3 He was polarized using the Rb spin-exchange method. We describe the measurement technique, present our results, and discuss some of the systematic effects associated with the method

  7. Neutron spin filter based on optically polarized sup 3 He in a near-zero magnetic field

    CERN Document Server

    Skoy, V R; Sorokin, V N; Kolachevsky, N N; Sobelman, I I; Sermyagin, A V

    2003-01-01

    A test of polarization of sup 3 He nuclei via spin-exchange collisions with optically pumped rubidium atoms in an extremely low applied magnetic field was carried out. Permalloy magnetic shields were used to prevent a fast relaxation of sup 3 He polarization owing to the inhomogeneity of a surrounding magnetic field. The whole installation was placed at the neutron beam line of the IBR-30 facility, and used as a neutron spin filter. Thus, a prototype of new design of neutron polarizer was introduced. We intend to apply this experience for the full-scale KaTRIn facility to test the time reversal violation in neutron-nuclear reactions.

  8. Dimensional crossover of effective orbital dynamics in polar distorted He 3 -A : Transitions to antispacetime

    Science.gov (United States)

    Nissinen, J.; Volovik, G. E.

    2018-01-01

    Topologically protected superfluid phases of He 3 allow one to simulate many important aspects of relativistic quantum field theories and quantum gravity in condensed matter. Here we discuss a topological Lifshitz transition of the effective quantum vacuum in which the determinant of the tetrad field changes sign through a crossing to a vacuum state with a degenerate fermionic metric. Such a transition is realized in polar distorted superfluid He 3 -A in terms of the effective tetrad fields emerging in the vicinity of the superfluid gap nodes: the tetrads of the Weyl points in the chiral A-phase of He 3 and the degenerate tetrad in the vicinity of a Dirac nodal line in the polar phase of He 3 . The continuous phase transition from the A -phase to the polar phase, i.e., the transition from the Weyl nodes to the Dirac nodal line and back, allows one to follow the behavior of the fermionic and bosonic effective actions when the sign of the tetrad determinant changes, and the effective chiral spacetime transforms to antichiral "anti-spacetime." This condensed matter realization demonstrates that while the original fermionic action is analytic across the transition, the effective action for the orbital degrees of freedom (pseudo-EM) fields and gravity have nonanalytic behavior. In particular, the action for the pseudo-EM field in the vacuum with Weyl fermions (A-phase) contains the modulus of the tetrad determinant. In the vacuum with the degenerate metric (polar phase) the nodal line is effectively a family of 2 +1 d Dirac fermion patches, which leads to a non-analytic (B2-E2)3/4 QED action in the vicinity of the Dirac line.

  9. Ring-diagram calculations of normal and spin-polarized 3He using the Aziz interactions

    International Nuclear Information System (INIS)

    Heyer, J.; Kiang, L.L.; Jiang, M.F.; Kuo, T.T.S.

    1991-01-01

    The authors calculate the ground-state energy of normal and spin-polarized 3 He within a model-space ring diagram framework where the particle-particle hole-hole (pphh) ring diagrams of the ground-state energy shift are summed up to all orders. The Aziz HFDHE2 and HFD-B(HE) interactions are employed. They first calculate a model space reaction matrix (G M ) whose intermediate states are required to be outside the chosen model space. The pphh ring diagrams with G M -matrix vertices are then summed within the model space by way of an RPA-type secular equation. The continuous single-particle spectrum of Mahaux is chosen. It is found that the inclusion of pphh ring diagrams gives a significant increase in the binding energy per particle (BE/A) as compared with Brueckner-Hartree-Fock calculations. For normal and spin-polarized 3 He their calculated values for BE/A and saturation densities are respectively (1.86 K, 0.72 angstrom -1 ) and (1.59 K, 0.91 angstrom -1 ), while the corresponding experimental values for normal 3 He are (2.47 K, 0.785 angstrom -1 ). 53 refs

  10. The search for high-energy deuterons in the 3He +3He reaction

    International Nuclear Information System (INIS)

    Pigeon, R.; Slobodrian, R.J.

    1979-01-01

    High-energy deuterons have been detected from the 3 He + 3 He reaction with a system sensitive to cross-sections of 0.6 nb sr -1 . Several tests have permitted to evaluate the small contribution of spurious events. The deuterons are kenematically consistent with the reaction 3 He + 3 He→ 2 H + 4 He + e + +ν, but the measured cross-section at 20deg laboratory is too high for a weak-interaction process; (1.3 +- 0.2) nb sr -1 . It might be due to an interaction of intermediate strength causing the decay of pp pairs ( 3 He) into deuterons. Other alternatives and the implications concerning fusion processes and the production of neutrinos in the sun are discussed in the text

  11. High-field 3He-F interaction at the surface of fluorocarbon spheres

    DEFF Research Database (Denmark)

    Schuhl, A.; Chapellier, M.; Rasmussen, Finn Berg

    1984-01-01

    High-field experiments on the relaxation betweenF in small Teflon spheres andHe on the surface are reported. WithHe as a monolayer, coupling times are found to be less than 5 sec, in magnetic fields up to 3 T and temperatures down to 50 mK, where electronic centers are completely polarized...

  12. Polarized 3He Gas Circulating Technologies for Neutron Analyzers

    Energy Technology Data Exchange (ETDEWEB)

    Watt, David [Xemed LLC, Durham, NH (United States); Hersman, Bill [Xemed LLC, Durham, NH (United States)

    2014-12-10

    We describe the development of an integrated system for quasi-continuous operation of a large volume neutron analyzer. The system consists of a non-magnetic diaphragm compressor, a prototype large volume helium polarizer, a surrogate neutron analyzer, a non-depolarizing gas storage reservoir, a non-ferrous valve manifold for handling gas distribution, a custom rubidium-vapor gas return purifier, and wire-wound transfer lines, all of which are immersed in a two-meter external magnetic field. Over the Phase II period we focused on three major tasks required for the successful deployment of these types of systems: 1) design and implementation of gas handling hardware, 2) automation for long-term operation, and 3) improvements in polarizer performance, specifically fabrication of aluminosilicate optical pumping cells. In this report we describe the design, implementation, and testing of the gas handling hardware. We describe improved polarizer performance resulting from improved cell materials and fabrication methods. These improvements yielded valved 8.5 liter cells with relaxation times greater than 12 hours. Pumping this cell with 1500W laser power with 1.25nm linewidth yielded peak polarizations of 60%, measured both inside and outside the polarizer. Fully narrowing this laser to 0.25nm, demonstrated separately on one stack of the four, would have allowed 70% polarization with this cell. We demonstrated the removal of 5 liters of polarized helium from the polarizer with no measured loss of polarization. We circulated the gas through a titanium-clad compressor with polarization loss below 3% per pass. We also prepared for the next phase of development by refining the design of the polarizer so that it can be engineer-certified for pressurized operation. The performance of our system far exceeds comparable efforts elsewhere.

  13. Measurements of the osmotic pressure in liquid mixtures of 3He and 4He near the lambda line and tricritical point

    International Nuclear Information System (INIS)

    Gearhart, C.A. Jr.

    1977-01-01

    Values of the concentration susceptibility (par. deltax/par. deltaΔ)/sub T,P/ near the lambda line and tricritical point in liquid mixtures of 3He and 4 He were calculated from measurements of osmotic pressure differences. Measurements were made by inducing a small 3 He mole fraction difference Δx between two chambrs separated by a pressure transducer, and measuring the resulting osmotic pressure difference as a function of temperature

  14. Specific heat of amorphous 3He films and confined liquid 3He

    International Nuclear Information System (INIS)

    Golov, A.; Pobell, F.

    1995-01-01

    We have measured the heat capacities of 3 He films and liquid 3 He in porous Vycor glass at 10 to 600 mK. With increasing the film thickness front 1 to 3 atomic layers , the specific heat evolves gradually from that typical to solid to that of liquid 3 He. At about 2 atomic layers, however, its low-temperature part is nearly temperature-independent; we interpret this as a result of gradual freezing of spins in an amorphous solid 3 He film with decreasing the temperature. The contribution of liquid 3 He in the center of the Vycor pores can be described as the specific heat of bulk liquid 3 He at corresponding pressures in the range 0 to 28 bar. The thickness of amorphous solid on the pore walls increases with external pressure roughly linearly. Preplating the walls with 4 He allows to determine the positions of 3 He atoms contributing to the surface specific heat at 10 to 50 mK. In addition, the contribution from the specific heat of 3 He- 4 He mixing at 100 to 600 mK is discussed as a function of pressure and amount of 4 He

  15. Spin structure of the 3He from the dd → 3Hen reaction

    International Nuclear Information System (INIS)

    Ladygin, V.P.; Ladygina, N.B.

    1995-01-01

    The polarization observables in the reaction dd → 3 Hen are considered. Their high sensitivity to the 3 He wave function at short distances is shown. Using of both polarized target and beam allows to extend sufficiently the number of possible experiments and to separate 3 He structure from the reaction mechanisms using different relative orientations of initial deuteron spins. 27 refs., 5 figs

  16. Measurement of electron drift velocities in the mixture of Xe and He for a new high-pressure Xe gamma-ray detector

    CERN Document Server

    Kobayashi, S; Dmitrenko, V V

    2003-01-01

    Drift velocities of electrons in a mixture of Xe (20 atm)-He (3 atm) were measured using a cylindrical high-pressure xenon chamber. The drift velocities were found to be greater than 3x10 sup 5 cm/s above the reduced electric field of 2.0x10 sup - sup 1 sup 8 V centre dot cm sup 2 at room temperature, which are close to those in Xe-H sub 2 (0.3%). The mixture of He gas into high-pressure xenon improved the resolving time of detectors because it increased the electron drift velocities. This implies that a high-pressure xenon chamber mixed with sup 3 He instead of He gas operates as a gamma-ray detector sensitive to thermal neutrons. (author)

  17. Comparative measurements between a Li-6 glass and a He-3 high-pressure gas scintillator

    International Nuclear Information System (INIS)

    Priesmeyer, H.G.; Fischer, P.; Harz, U.; Soldner, B.

    1983-01-01

    The He-3 high-pressure gas scintillation neutron detector commercially available as LND 800, has been compated to a Li-6 glass scintillator type NE 912. (n,γ) pulse height discrimination capabilities and neutron detection efficiencies have been determined. The objective of these measurements was to try to improve the Kiel Fast-Chopper TOF detector system by using a gasscintillator, which could cover the neutron beam geometry and by which gamma ray background contributions could be reduced. The time response always meets the requirements of a chopper experiment, but the neutron detection efficiency of the Li-6 glasses now used had to be maintained. (orig./HP) [de

  18. Superfluid 3He dynamcs in 3He - 4He solutions

    International Nuclear Information System (INIS)

    Mejerovich, A.Eh.

    1984-01-01

    The dynamics of a 3 He- 4 He superfluid solution with two condensates ( 3 He and 4 He) is investigated. Despite the fact that the hydrodynamics of the system is a three-velocity one (two superfluid and one normal velocity), all the thermo- and hydrodynamic functions are determined by the value of only a single linear combination of the velocities. 0n the basis of an analogy between a moving solution and a BCS system with coupling with a non-zero momentum, the dependence of the thermodynamic quantities on the velocities and critical velocities can easily be calculated for both homogeneous and inhomogeneous phases of the solution. In a magnetic field the temperature oscillations (analogue of second sound for a superfluid solution) are accompanied by oscillations of the magnetic moment. The velocity and damping of the spin-temperature waves are determined. The orienting action of a current on the inhomogeneous phases of the solution is discussed. It is shown that the energy and size of the vortexes in a superfluid solution are, due to drag effects, oscillating functions of the effective mass of the 3 He quasirartictes (pressure). At a pressure of the order of 10 atm a first order transition should take place in the vortex line which is accompanied by an abrupt change of the circulations of superfluid velocity of 3 He for a fixed circulation of the 4 He velocity

  19. Research and design of 3He pressure control loop

    International Nuclear Information System (INIS)

    Huang Xin; Zhang Peisheng; Tang Guoliang; Zhang Aimin; Zhang Yingchao

    2008-01-01

    In order to carry out power transient tests for PWR fuel element in China Advanced Research Reactor (CARR), the research and conceptual design of 3He pressure control loop were completed. The working principle, design parameters and technological flow of the loop were described. It is seen that the a He loop can adjust the power of the tested PWR fuel element rapidly, evenly and flexibly and it is an optimal path to realize the power transient regulation for tested PWR fuel. (authors)

  20. First measurement of the electric formfactor of the neutron in the exclusive quasielastic scattering of polarized electrons from polarized 3He

    International Nuclear Information System (INIS)

    Meyerhoff, M.; Eyl, D.; Frey, A.; Andresen, H.G.; Annand, J.R.M.; Aulenbacher, K.; Becker, J.; Blume-Werry, J.; Dombo, T.; Drescher, P.; Ducret, J.E.; Fischer, H.; Grabmayr, P.; Hall, S.; Hartmann, P.; Hehl, T.; Heil, W.; Hoffmann, J.; Kellie, J.D.; Klein, F.; Leduc, M.; Moeller, H.; Nachtigall, C.; Ostrick, M.; Otten, E.W.; Owens, R.O.; Pluetzer, S.; Reichert, E.; Rohe, D.; Schaefer, M.; Schearer, L.D.; Schmieden, H.; Steffens, K.; Surkau, R.; Walcher, T.

    1995-01-01

    A first measurement of the asymmetry in quasielastic scattering of longitudinally polarized electrons from a polarized 3 He gas target in coincidence with the knocked out neutron is reported. This measurement was made feasible by the cw beam of the 855 meV Mainz Microtron MAMI. It allows a determination of the electric formfactor of the neutron G n E independent of binding effects to first order. At bar Q 2 =0.31 (GeV/c) 2 two asymmetries bar A parallel (rvec S He parallel rvec q) and bar A perpendicular (rvec S He perpendicular rvec q) have been measured giving bar A parallel =(-7.40±0.73%) and bar A perpendicular =(0.89±0.30)%. The ratio bar A perpendicular /bar A parallel is independent of the absolute value of the electron and target polarization and yields G n E =0.035±0.012±0.005. copyright 1995 American Institute of Physics

  1. Polarized 3He gas circulating technologies for neutron analyzers

    Energy Technology Data Exchange (ETDEWEB)

    Watt, David W. [Xemed, LLC, Durham, NH (United States)

    2017-10-02

    We outline our project to develop a circulating polarized helium-3 system for developing of large, quasi-continuously operating neutron analyzers. The project consisted of four areas: 1) Development of robust external cavity narrowed diode laser output with spectral line width < 0.17 nm and power of 2000 W. 2) Development of large glass polarizing cells using cell surface treatments to obtain long relaxation lifetimes. 3) Refinements of the circulation system with an emphasis on gas purification and materials testing. 4) Design/fabrication of a new polarizer system. 5) Preliminary testing of the new polarizer. 1. Developed Robust High-Power Narrowed Laser The optical configuration of the laser was discussed in the proposal and will be reviewed in the body of this report. The external cavity is configured to mutually lock the wavelength of five 10-bar laser stacks. All the logistical milestones were been met and critical subsystems- laser stack manifold and power divider, external laser cavity, and output telescope- were assembled and tested at low power. Each individual bar is narrowed to ~0.05 nm; when combined the laser has a cumulative spectral width of 0.17 nm across the entire beam due to variations of the bars central wavelength by +/- 0.1 nm, which is similar to that of Volume Bragg Grating narrowed laser bars. This configuration eliminates the free-running “pedestal” that occurs in other external cavity diode lasers. The full-scale laser was completed in 2016 and was used in both the older and newer helium polarizers. This laser was operated at 75% power for periods of up to 8 hours. Once installed, the spectrum became slightly broader (~.25 nm) at full power; this is likely due to very slight misalignments that occurred during handling. 2. Developed the processes to create uniform sintered sol-gel coatings. Our work on cell development comprised: 1) Production of large GE180 cells and explore different means of cell preparation, and 2) Development of

  2. Development of a {sup 3}He magnetometer for a neutron electric dipole moment experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kraft, Andreas; Heil, Werner; Lauer, Thorsten; Neumann, Daniel [Johannes Gutenberg University, Institute of Physics, Mainz (Germany); Koch, Hans-Christian [Johannes Gutenberg University, Institute of Physics, Mainz (Germany); University of Fribourg, Physics Department, Fribourg (Switzerland); Daum, Manfred [Paul Scherrer Institute, Villigen (Switzerland); Pazgalev, Anatoly [Ioffe Institute, St Petersburg (Russian Federation); Sobolev, Yuri [Johannes Gutenberg University, Institute of Nuclear Chemistry, Mainz (Germany); Petersburg Nuclear Physics Institute, Gatchina (Russian Federation); Weis, Antoine [University of Fribourg, Physics Department, Fribourg (Switzerland)

    2014-01-01

    We have developed a highly sensitive {sup 3}He magnetometer for the accurate measurement of the magnetic field in an experiment searching for an electric dipole moment of the neutron. By measuring the Larmor frequency of nuclear spin polarized {sup 3}He atoms a sensitivity on the femto-Tesla scale can be achieved. A {sup 3}He/Cs-test facility was established at the Institute of Physics of the Johannes Gutenberg University in Mainz to investigate the readout of {sup 3}He free induction decay with a lamp-pumped Cs magnetometer. For this we designed and built an ultra-compact and transportable polarizer unit which polarizes {sup 3}He gas up to 55% by metastability exchange optical pumping. The polarized {sup 3}He was successfully transfered from the polarizer into a glass cell mounted in a magnetic shield and the {sup 3}He free induction decay was detected by a lamp-pumped Cs magnetometer. (orig.)

  3. End-compensated magnetostatic cavity for polarized 3He neutron spin filters.

    Science.gov (United States)

    McIver, J W; Erwin, R; Chen, W C; Gentile, T R

    2009-06-01

    We have expanded upon the "Magic Box" concept, a coil driven magnetic parallel plate capacitor constructed out of mu-metal, by introducing compensation sections at the ends of the box that are tuned to limit end-effects similar to those of short solenoids. This ability has reduced the length of the magic box design without sacrificing any loss in field homogeneity, making the device far more applicable to the often space limited neutron beam line. The appeal of the design beyond affording longer polarized 3He lifetimes is that it provides a vertical guide field, which facilitates neutron spin transport for typical polarized beam experiments. We have constructed two end-compensated magic boxes of dimensions 28.4 x 40 x 15 cm3 (length x width x height) with measured, normalized volume-averaged transverse field gradients ranging from 3.3 x 10(-4) to 6.3 x 10(-4) cm(-1) for cell sizes ranging from 8.1 x 6.0 to 12.0 x 7.9 cm2 (diameter x length), respectively.

  4. Improved results for the 2H(d, n)3He transverse vector polarization-transfer coefficient Kyy'(0o) at low energies

    International Nuclear Information System (INIS)

    Roper, C.D.; Dunham, J.D.; Clegg, T.B.; Mendez, A.J.; Tornow, W.; Walter, R.L.

    2010-01-01

    Measurements of the 2 H(d, n) 3 He transverse vector polarization-transfer coefficient K y y' at 0 o . are reported for 29 outgoing neutron energies between 3.94 and 8.47 MeV. Our new results determine K y y' (0 o ) more accurately than previous data, especially for neutron energies below 5 MeV. Low-energy data for this reaction are important both as a high-intensity source of highly polarized neutrons for nuclear physics studies with polarized neutron beams, and as a test of the emerging theoretical descriptions of the four-body system, where recently substantial progress has been made. (author)

  5. Measurement of "pretzelosity" asymmetry of charged pion production in semi-inclusive deep inelastic scattering on a polarized 3He target

    Science.gov (United States)

    Zhang, Y.; Qian, X.; Allada, K.; Dutta, C.; Huang, J.; Katich, J.; Wang, Y.; Aniol, K.; Annand, J. R. M.; Averett, T.; Benmokhtar, F.; Bertozzi, W.; Bradshaw, P. C.; Bosted, P.; Camsonne, A.; Canan, M.; Cates, G. D.; Chen, C.; Chen, J.-P.; Chen, W.; Chirapatpimol, K.; Chudakov, E.; Cisbani, E.; Cornejo, J. C.; Cusanno, F.; Dalton, M. M.; Deconinck, W.; de Jager, C. W.; De Leo, R.; Deng, X.; Deur, A.; Ding, H.; Dolph, P. A. M.; Dutta, D.; El Fassi, L.; Frullani, S.; Gao, H.; Garibaldi, F.; Gaskell, D.; Gilad, S.; Gilman, R.; Glamazdin, O.; Golge, S.; Guo, L.; Hamilton, D.; Hansen, O.; Higinbotham, D. W.; Holmstrom, T.; Huang, M.; Ibrahim, H. F.; Iodice, M.; Jiang, X.; Jin, G.; Jones, M. K.; Kelleher, A.; Kim, W.; Kolarkar, A.; Korsch, W.; LeRose, J. J.; Li, X.; Li, Y.; Lindgren, R.; Liyanage, N.; Long, E.; Lu, H.-J.; Margaziotis, D. J.; Markowitz, P.; Marrone, S.; McNulty, D.; Meziani, Z.-E.; Michaels, R.; Moffit, B.; Muñoz Camacho, C.; Nanda, S.; Narayan, A.; Nelyubin, V.; Norum, B.; Oh, Y.; Osipenko, M.; Parno, D.; Peng, J. C.; Phillips, S. K.; Posik, M.; Puckett, A. J. R.; Qiang, Y.; Rakhman, A.; Ransome, R. D.; Riordan, S.; Saha, A.; Sawatzky, B.; Schulte, E.; Shahinyan, A.; Shabestari, M. H.; Širca, S.; Stepanyan, S.; Subedi, R.; Sulkosky, V.; Tang, L.-G.; Tobias, W. A.; Urciuoli, G. M.; Vilardi, I.; Wang, K.; Wojtsekhowski, B.; Yan, X.; Yao, H.; Ye, Y.; Ye, Z.; Yuan, L.; Zhan, X.; Zhang, Y.-W.; Zhao, B.; Zheng, X.; Zhu, L.; Zhu, X.; Zong, X.; Jefferson Lab Hall A Collaboration

    2014-11-01

    An experiment to measure single-spin asymmetries of semi-inclusive production of charged pions in deep-inelastic scattering on a transversely polarized 3He target was performed at Jefferson Laboratory in the kinematic region of 0.16 3He, which are expressed as the convolution of the h1T ⊥ transverse-momentum-dependent distribution functions and the Collins fragmentation functions in the leading order, were measured for the first time. Under the effective polarization approximation, we extracted the corresponding neutron asymmetries from the measured 3He asymmetries and cross-section ratios between the proton and 3He. Our results show that both π± on 3He and on neutron pretzelosity asymmetries are consistent with zero within experimental uncertainties.

  6. Spin effects in medium-energy electron-3He scattering

    International Nuclear Information System (INIS)

    van den Brand, J.F.J.; Alarcon, R.; Bauer, T.

    1998-01-01

    New physics can be accessed by scattering polarized electrons from a polarized 3 He internal gas target. It is discussed how the asymmetries for the reactions 3 vector He(vector e,e'), 3 vector He(vector e,e'p), 3 vector He(vector e,e'n), 3 vector He(vector e,e'd), and 3 vector He(vector e,e'pn) may provide precise information on the S' and the D-wave parts of the 3 He ground-state wave function, the neutron form factors, and the role of spin-dependent reaction mechanism effects. The experiment uses up to 900 MeV (polarized) electrons from the AmPS storage ring in Amsterdam, Netherlands, in combination with large acceptance electron and hadron detectors. (orig.)

  7. Feasibility study of a sup 3 He-magnetometer for neutron electric dipole moment experiments

    CERN Document Server

    Borisov, Y; Leduc, M; Lobashev, V; Otten, E W; Sobolev, Y

    2000-01-01

    We report on a sup 3 He-magnetometer capable of detecting tiny magnetic field fluctuations of less than 10 sup - sup 1 sup 4 T in experiments for measuring the electric dipole moment (EDM) of the neutron. It is based on the Ramsey technique of separated oscillating fields and uses nuclear spin-polarized sup 3 He gas which is stored in two vessels of V approx =10 l in a sandwich-type arrangement around the storage bottle for ultra-cold neutrons (UCN). The gas is polarized by means of optical pumping in a separate, small discharge cell at pressures around 0.5 mbar and is then expanded into the actual magnetometer volume. To detect the polarization of sup 3 He gas at the end of the storage cycle the gas is pumped out by means of an oil-diffusion pump and compressed again into the discharge cell where optical detection of nuclear polarization is used.

  8. Recent Spin Pump Experiments on Superfluid 3He-A1

    Science.gov (United States)

    Yamaguchi, A.; Kamada, N.; Motoyama, G.; Sumiyama, A.; Aoki, Y.; Okuda, Y.; Kubota, M.; Kojima, H.

    2013-05-01

    The superfluid 3He A1 phase, containing a spin-polarized condensate allows us to explore the dynamics of superfluid spin current. In the mechano-spin effect (MSE), a mechanically applied pressure gradient and a superleak-spin filter enable one to directly boost spin polarization of 3He in a small chamber. We are developing new apparatus for achieving greater enhancement of spin density. A development of a new-type 3He-hydraulic actuator has been already reported. We present here the construction of new-type of superleak-spin-filter made of packed powder aluminum oxide (referred as PAP-SL). The PAP-SL is popular in the study of superfluid 4He, but has not been established for that of the superfluid 3He. The attempt to construct the PAP-SL for the spin pump experiment was made by using aluminum oxide powder with nominal 1 μm powder diameter and with packing fraction of 40 %. Before executing the experiment, the nuclear demagnetization cryostat of ISSP, Univ. Tokyo which has been used for this experimental activity, was heavily damaged by the 2011 Great East Japan (Higashi Nihon) Earthquake. The repair work and earthquake damage protection strengthening has just been accomplished.

  9. Accurate 3He polarimetry using the Rb Zeeman frequency shift due to the Rb-3He spin-exchange collisions

    International Nuclear Information System (INIS)

    Romalis, M.V.; Cates, G.D.

    1998-01-01

    We describe a method of 3 He polarimetry relying on the polarization-dependent frequency shift of the Rb Zeeman resonance. Our method is ideally suited for on-line measurements of the 3 He polarization produced by spin-exchange optical pumping. To calibrate the frequency shift we performed an accurate measurement of the imaginary part of the Rb- 3 He spin-exchange cross section in the temperature range typical for spin-exchange optical pumping of 3 He. We also present a detailed study of possible systematic errors in the frequency shift polarimetry. copyright 1998 The American Physical Society

  10. He3 cryostat

    International Nuclear Information System (INIS)

    Novichkova, L.G.; Kulikov, Yu.V.; Stashkova, N.M.

    1992-01-01

    An effective cryostat featuring a one-cycle He 3 refrigerator with a cryosorption pump is described. Gaseous He 3 in contained in a low-pressure vessel having a common wall with a liquid N 2 bath. Due to this, the gas is cooled before sorption and the sorption rate increases approximately by a factor of ten. The cryostat is provided with a needle valve which cuts off the ballast volume of the pipelines from the refrigerator. As a result, the pressure of He 3 vapours increases before condensation and with refrigerator dimensions selected properly, the liquefaction coefficient reaches approximately 80%. Test results of the cryostat and its specifications are presented. (Author)

  11. A compact spin-exchange optical pumping system for 3He polarization based on a solenoid coil, a VBG laser diode, and a cosine theta RF coil

    Science.gov (United States)

    Lee, Sungman; Kim, Jongyul; Moon, Myung Kook; Lee, Kye Hong; Lee, Seung Wook; Ino, Takashi; Skoy, Vadim R.; Lee, Manwoo; Kim, Guinyun

    2013-02-01

    For use as a neutron spin polarizer or analyzer in the neutron beam lines of the HANARO (High-flux Advanced Neutron Application ReactOr) nuclear research reactor, a 3He polarizer was designed based on both a compact solenoid coil and a VBG (volume Bragg grating) diode laser with a narrow spectral linewidth of 25 GHz. The nuclear magnetic resonance (NMR) signal was measured and analyzed using both a built-in cosine radio-frequency (RF) coil and a pick-up coil. Using a neutron transmission measurement, we estimated the polarization ratio of the 3He cell as 18% for an optical pumping time of 8 hours.

  12. X-ray-induced thinning of 3He and 3He/4He mixture films

    International Nuclear Information System (INIS)

    Penanen, Konstantin; Fukuto, Masafumi; Silvera, Isaac F.; Pershan, Peter

    2000-01-01

    Films of isotopic mixtures of helium have been studied using x-ray specular reflectivity techniques. In contrast with superfluid 4 He films, x-ray exposure causes a reduction in the thickness of 4 He films above the superfluid transition as well as films of pure 3 He and 3 He/ 4 He mixtures. One proposed model that could account for this effect is a charging model, in which thinning is caused by electrostatic pressure of free charges that accumulate on the helium surface. Unfortunately, this model is not fully consistent with all of the experimental observations. A localized heating model, in which indirect heating of the film causes it to thin would explain the data if there were dissipative film flow in the 3 He/ 4 He mixtures at temperatures where the bulk is superfluid. We argue that various published experimental results suggest such an effect. In this model, film thinning data for dilute 3 He/ 4 He films indicates dissipation that is linear in 3 He content of the film over two orders of magnitude

  13. Improved Results for the H-2(d, n)(3) He Transverse Vector Polarization- Transfer Coefficient K-y(y)' (0 degrees) at Low Energies

    International Nuclear Information System (INIS)

    Roper, C.D.; Clegg, T.; Dunham, J.D.; Mendez, Anthony J. II; Tornow, W.; Walter, R.L.

    2010-01-01

    Measurements of the H-2(d, n)(3) He transverse vector polarization-transfer coefficient K-y(y)' at 0 degrees. are reported for 29 outgoing neutron energies between 3.94 and 8.47MeV. Our new results determine K-y(y)' (0 degrees) more accurately than previous data, especially for neutron energies below 5MeV. Low-energy data for this reaction are important both as a high-intensity source of highly polarized neutrons for nuclear physics studies with polarized neutron beams, and as a test of the emerging theoretical descriptions of the four-body system, where recently substantial progress has been made.

  14. Thermodynamic properties of 3He--4He mixtures near Tlambda

    International Nuclear Information System (INIS)

    Kakizaki, A.; Satoh, T.

    1976-01-01

    In order to investigate 3 He impurity effects on the superfluid transition, measurements were made on the thermodynamic quantities, specific heat, thermal expansion coefficients, and pressure dependence of the lambda-transition temperature of three 3 He-- 4 He mixtures and pure 4 He in the neighborhood of the lambda-transition temperature under their saturated vapor pressure. Making use of these measured quantities, it is shown that the so-called Pippard--Buckingham--Fairbank relation holds for 3 He-- 4 He mixtures as well as for pure 4 He, at least in the temperature region of 10 -4 K less than or equal to absolute value (T - T/sub lambda/) less than or equal to 10 -2 K. Based on this, the 3 He impurity effects on the behavior of the specific heat near the lambda-transition are discussed

  15. Measurement of double polarized asymmetries in quasi-elastic processes ${}^3\\vec{He}(\\vec{e},e' d)$ and ${}^3\\vec{He}(\\vec{e},e' p)$

    Energy Technology Data Exchange (ETDEWEB)

    Mihovilovic, Miha [Univ. of Ljubljana (Slovenia)

    2012-01-01

    This thesis is dedicated to a study of a spin-isospin structure of the polarized 3He. First, an introduction to the spin structure of 3He is given, followed by a brief overview of past experiments. The main focus of the thesis is the E05-102 experiment at Jefferson Lab, in which the reactions ${}^3\\vec{He}(\\vec{e},e' d)$ and ${}^3\\vec{He}(\\vec{e},e' p)$ in the quasi-elastic region were studied. The purpose of this experiment was to better understand the effects of the S'- and D-state contributions to the 3He ground-state wave-functions by a precise measurement of beam-target asymmetries Ax and Az in the range of recoil momenta from 0 to about 300 MeV/c. The experimental equipment utilized in these measurements is described, with special attention devoted to the calibration of the hadron spectrometer, BigBite. Results on the measured asymmetries are presented, together with first attempts at their comparison to the state-of-the art Faddeev calculations. The remaining open problems and challenges for future work are also discussed.

  16. 3He(d,p)4He reaction calculation with three-body Faddeev equations

    International Nuclear Information System (INIS)

    Oryu, S.; Uzu, E.; Sunahara, H.; Yamada, T.; Tabaru, G.; Hino, T.

    1998-01-01

    In order to investigate the 3 He-n-p system as a three-body problem, we have formulated 3 He-n and 3 H-p effective potentials using both a microscopic treatment and a phenomenological approach. In the microscopic treatment, potentials are generated by means of the resonating group method (RGM) based on the Minnesota nucleon-nucleon potential. These potentials are converted into separable form by means of the microscopic Pauli correct (MPC) method. The MPC potentials are properly formulated to avoid Pauli forbidden states. The phenomenological potentials are obtained by modifying parameters of the EST approximation to the Paris nucleon-nucleon potential, such that they fit the low-energy 3 He-n, 3 H-p, and 3 He-p phase shifts. Therefore, they describe the 3 He-n differential cross section, the polarization observables, and the energy levels of 4 He. The 3 He-n-p Faddeev equations are solved numerically. We reproduce correctly the ground state and the first excited state of 5 Li. Furthermore, the Paris-type potential is used to investigate the 3 He(d,p) 4 He reaction at a deuteron bombarding energy of 270 MeV, where the system is treated as a three-body problem. Results for the polarized and unpolarized differential cross sections demonstrate convergence of the Born series. (orig.)

  17. Recent on-beam tests of wide angle neutron polarization analysis with a 3He spin filter: Magic PASTIS on V20 at HZB

    Science.gov (United States)

    Babcock, E.; Salhi, Z.; Gainov, R.; Woracek, R.; Soltner, H.; Pistel, P.; Beule, F.; Bussmann, K.; Heynen, A.; Kämmerling, H.; Suxdorf, F.; Strobl, M.; Russina, M.; Voigt, J.; Ioffe, A.

    2017-06-01

    A complete XYZ polarization analysis solution is under development for the new thermal time of flight spectrometer TOPAS [1], to be operated in the coming east neutron guide hall at the MLZ. Polarization Analysis Studies on a Thermal Inelastic Spectrometer, commonly called PASTIS [2], is based on polarized 3He neutron spin filters and an XYZ field configuration for the sample environment and a polarization-preserving neutron guide field. The complete system was designed to provide adiabatic transport of the neutron polarization to the sample position while maintaining the homogeneity of the XYZ field. This system has now been tested on the polarized time-of-flight ESS test beam line V20 at HZB [3]. Down to the minimum wavelength of 1.6 Å on the instrument, the magnetic configuration worked ideally for neutron spin transport while giving full experimental freedom to change between the X, Y or Z field configuration. The 3He cell used was polarized at the 3He lab of the JCNS at the MLZ in Garching and transported to HZB in Berlin via car showing that such a transport is indeed feasible for such experiments. We present results of this test and the next steps forward.

  18. Measurements of the osmotic pressure in liquid mixtures of 3He and 4He near the lambda line and tricritical point

    International Nuclear Information System (INIS)

    Gearhart, C.A. Jr.

    1977-06-01

    Values of the concentration susceptibility near the lambda line and tricritical point in liquid mixtures of 3 He and 4 He have been calculated from measurements of osmotic pressure differences. Measurements were made by inducing a small 3 He mole fraction difference Δx between two chambers separated by a pressure transducer, and measuring the resulting osmotic pressure difference as a function of temperature. Osmotic equilibrium was established through a Vycor glass superleak, which for 3 He mole fraction x > 0.55 functions not only in the superfluid phase but in portions of the normal fluid region of the phase diagram as well. Measurements were made at four 3 He mole fractions, x = 0.59, x = 0.64, x = 0.68, and x = 0.70. In contrast with determinations from light scattering and vapor pressure measurements, the present measurements show a pronounced peak at the lambda transition for the two values of x less than the tricritical value (x/sub t/ = 0.675). The susceptibilities are consistent with α = 0 both above and below the lambda transition except at x = 0.64, where some combination of α and α' greater than zero seems to be preferred. (The result α = 0 corresponds to a logarithmic divergence.) It is possible that this positive value of α or α' represents the influence of tricritical effects. It should be emphasized that there is considerable ambiguity in our determination of α, with acceptable least-squares fits corresponding to values of α between 0.0 and 0.2 being found at both concentrations, both above and below T/sub lambda/. The results appear to be consistent with the results of other experiments away from the lambda line, and also to be consistent with a simple tricritical scaling relationship

  19. Structure and dynamics of molecular complex He2*(a3Σu+) in condensed phases of helium

    International Nuclear Information System (INIS)

    Kafanov, S.G.; Parshin, A.Ya.; Tadoshchenko, I.A.

    2000-01-01

    The absorption spectra of the helium triplet metastable molecules in the a 3 Σ u + states in the liquid 4 He and 3 He by various pressures and in the 3 He dense gas are studied. The analysis of the spectrum, corresponding to the a 3 Σ u + → c 3 Σ g + transition, proves the conclusion on the availability of a microscopic bubble, surrounding the molecule in the liquid helium. Simple approximation of the wave function of the molecule valent electron is proposed and the bubble parameters under various experimental conditions are determined. The coefficient conditions are determined. The coefficient of the molecular recombination in the liquid 3 He and 4 He by different pressures and in the 3 He cold gas is experimentally determined. The obtained results agree well with the mutual recombination theory. It is shown, that molecular polarization in the helium condensed phases under the magnetic field effect does not lead to their mutual recombination [ru

  20. Small-angle neutron polarization for the 2H(d vector,n vector)3He reaction near Esub(d) = 8MeV

    International Nuclear Information System (INIS)

    Tornow, W.; Woye, W.; Mack, G.

    1981-01-01

    Considerable improvement in the quality of analyzing power experiments performed with polarized fast neutrons has been achieved during the last few years by using neutrons from the polarization transfer reaction 2 H(d vector,n vector) 3 He at a reaction angle of theta = 0 0 . To compromise in these experiments between intensity problems and finite geometry corrections, it is desirable in some instances to subtend a full-width angle Δtheta of 20 0 (lab) centered about theta = 0 0 . In order to investigate the suitability of this reaction as a source of polarized neutrons for cases where the scatterer is close to the neutron source, the neutron polarization of the reaction 2 H(d vector,n vector) 3 He has been studied with Δtheta of about 3 0 in 3 0 steps out to theta = 20 0 (lab). An incident deuteron energy near 8 MeV was chosen to yield outgoing neutrons at 11.0 MeV, a typical energy for neutron analyzing power experiments. It is found that the effective neutron polarization, a combination of the two polarizations measured when the direction of the deuteron polarization is inverted or flipped at the polarized ion source, is large and nearly constant for angles between theta = 0 0 and theta = 10 0 (lab). (orig.)

  1. First results from Tyrex, the new polarized-3He filling station at ILL

    International Nuclear Information System (INIS)

    Andersen, K.H.; Chung, R.; Guillard, V.; Humblot, H.; Jullien, D.; Lelievre-Berna, E.; Petoukhov, A.; Tasset, F.

    2005-01-01

    A new filling station for nuclear polarisation of 3 He gas has been constructed at the ILL, Grenoble. The 'Tyrex' machine uses metastability-exchange optical pumping for polarising the 3 He gas at about 1 mbar pressure. The gas is then compressed up to several bars via a hydraulic titanium-alloy piston compressor. The machine can provide about 1.5 bar-l/h of polarised gas--an order-of-magnitude increase over the first filling station installed at the ILL in 1996. The compressed, polarised gas is used for polarising neutron beams for condensed-matter and fundamental physics experiments. First results are presented and examples of implementations on existing neutron instruments at ILL are described

  2. Study of the multiple exchange frequencies in bcc 3He by thermodynamic measurements

    International Nuclear Information System (INIS)

    Bernier, M.; Suaudeau, E.; Roger, M.

    1987-08-01

    To study the multiple exchange hamiltonian of solid 3 He we measured the contribution of the spin exchange to the pressure of bcc solid in various magnetic fields (O≤ H≤ 7.5T). Due to the nature of the atomic exchange of a fermion system this contribution is a strong function of the spin polarization. The characteristic frequencies of the exchange hamiltonian are obtained by fitting the pressure measurements with the results of a statistical calculation using a high temperature series expansion of the hamiltonian in a temperature range where both the magnetic effect is significant and the expansion converges (7mK < T < 30mK). We discuss the results obtained for two molar volumes

  3. Kinetic energy of He atoms in liquid 4He-3He mixtures

    International Nuclear Information System (INIS)

    Senesi, R.; Andreani, C.; Fielding, A.L.; Mayers, J.; Stirling, W.G.

    2003-01-01

    Deep inelastic neutron scattering measurements on liquid 3 He- 4 He mixtures in the normal phase have been performed on the VESUVIO spectrometer at the ISIS pulsed neutron source at exchanged wave vectors of about q≅120.0 A -1 . The neutron Compton profiles J(y) of the mixtures were measured along the T=1.96 K isotherm for 3 He concentrations, x, ranging from 0.1 to 1.0 at saturated vapor pressures. Values of kinetic energies of 3 He and 4 He atoms as a function of x, (x), were extracted from the second moment of J(y). The present determinations of (x) confirm previous experimental findings for both isotopes and, in the case of 3 He, a substantial disagreement with theory is found. In particular (x) for the 3 He atoms is found to be independent of concentration yielding a value 3 (x=0.1)≅12 K, much lower than the value suggested by the most recent theoretical estimates of approximately 19 K

  4. Molar volume dependence of the pressure of solid 3He at very low temperatures

    International Nuclear Information System (INIS)

    Mamiya, T.; Sawada, A.; Fukuyama, H.; Iwahashi, K.; Masuda, Y.

    1983-01-01

    The pressure of solid 3 He has been measured as a function of temperature T between 0.3 and 50 mK at molar volumes between 24.19 and 23.31 cm 3 . The entropy discontinuity obtained from the pressure jump at the ordering transition turned out to be almost independent of molar volumes, being about 0.40Rln2 in the studied range of molar volumes

  5. 3He flow in dilute 3He-4He mixtures at temperatures between 10 and 150 mK

    International Nuclear Information System (INIS)

    Castelijns, C.A.M.; Kuerten, J.G.M.; de Waele, A.T.A.M.; Gijsman, H.M.

    1985-01-01

    The mutual friction between 3 He and 4 He II below 150 mK has been studied. Empirical relations for the adiabatic and the nonadiabatic flow properties of 3 He moving through 4 He have been determined using a dilution refrigerator with a single mixing chamber. The validity of the relations is verified by osmotic-pressure measurements and by measuring the properties of a double-mixing-chamber system. It is shown that superleak shunts have a strong effect on the flow characteristics. From the nonadiabatic flow properties an expression is derived for the mutual-friction-force density between 3 He and 4 He II. This has a strong resemblance to the Gorter-Mellink mutual-friction-force density between the normal and the superfluid components in pure 4 He II. It is speculated that the 3 He flow in our systems generates a 4 He vortex tangle, which leads to the observed mutual friction between 3 He and 4 He and also to a strong clamping of the 4 He to the walls

  6. The g-u interference oscillations observed in the emission cross sections and the optical polarizations in He+-He collisions

    International Nuclear Information System (INIS)

    Tani, M.; Hishikawa, A.; Okasaka, R.

    1991-01-01

    We have observed emission radiation from helium atoms excited in He + -He collisions by the direct and electron capture processes over the energy range 0.5-20 keV. The relative emission cross sections for transitions 2 1,3 P-3 1,3 S, 2 1,3 S-3 1,3 P and 2 1,3 P-2 1,3 D have been determined. Degrees of optical polarization have also been determined for the P- and D-state excitations. The emission cross section of the direct excitation and that of the electron capture excitation show oscillations against impact energy, which are in antiphase with each other. The polarization degrees for both processes are nearly the same magnitude and show weak oscillations in antiphase with each other. The oscillations of the cross section and those of the polarization degree are in phase in some cases and in antiphase in other cases. These oscillations are interpreted as due to the interference between the gerade and ungerade states of the helium quasimolecular ion. From the amplitude ratio and the phase correlation between the oscillations of the cross section and those of the polarization degree we find that the predominant g-u interference pair is Π g -Π u . (author)

  7. Development of a compact in situ polarized ³He neutron spin filter at Oak Ridge National Laboratory.

    Science.gov (United States)

    Jiang, C Y; Tong, X; Brown, D R; Chi, S; Christianson, A D; Kadron, B J; Robertson, J L; Winn, B L

    2014-07-01

    We constructed a compact in situ polarized (3)He neutron spin filter based on spin-exchange optical pumping which is capable of continuous pumping of the (3)He gas while the system is in place in the neutron beam on an instrument. The compact size and light weight of the system simplifies its utilization on various neutron instruments. The system has been successfully tested as a neutron polarizer on the triple-axis spectrometer (HB3) and the hybrid spectrometer (HYSPEC) at Oak Ridge National Laboratory. Over 70% (3)He polarization was achieved and maintained during the test experiments. Over 90% neutron polarization and an average of 25% transmission for neutrons of 14.7 meV and 15 meV was also obtained.

  8. Homogeneous nucleation in phase separation of solid 3He-4He mixtures

    International Nuclear Information System (INIS)

    Poole, M.; Smith, A.; Maidanov, V.A.; Rudavskii, E.Ya.; Grigor'ev, V.N.; Slezov, V.V.; Saunders, J.; Cowan, B.

    2003-01-01

    NMR and pressure have been measured during phase separation in solid 3 He- 4 He mixtures. Spin echoes were used to observe bounded diffusion and to estimate the diffusion coefficient, size and nuclei concentration in the 3 He-enriched phase. The characteristic phase separation time constant of the mixture was found from pressure measurements. The results argue convincingly for homogeneous nucleation. The surface tension of the nuclei is found independently from NMR and from pressure measurements; the two determinations agree well and yield a surface tension coefficient of 4.9x10 -6 J m -2

  9. Heat pulses in dilute 3He-4He mixtures

    International Nuclear Information System (INIS)

    Husson, L.P.J.

    1983-01-01

    The propagation of heat pulses in dilute 3 He- 4 He mixtures under pressure along a tube, which is long compared to its diameter, is discussed. At high temperatures, where the excitations are in local equilibrium with one another, the propagation of heat pulses in the liquid is determined by the phenomenon of second sound, which is essentially a density wave in the excitation gas. The velocity and attenuation of second sound can be determined from the shape of the transmitted pulse. Measurements on the scattering and absorption of phonons are presented, together with a detailed description of the experimental technique and the electronic equipment. Measurements on the velocity and absorption of second sound are presented. From the results for the velocity of second sound in pure 4 He, values of the phonon and roton parameters are deduced. The velocity data in the mixtures have been used to calculate values of the effective mass of 3 He in superfluid 4 He. The results of these calculations have been compared with values of the effective mass obtained by other authors. The coefficient of second-sound absorption in pure 4 He is computed from theory, making use of the phonon and roton parameters calculated from the second-sound velocity data in pure 4 He. The experimental results on the scattering and absorption of phonons have been analysed. The empirical expressions for the scattering and absorption rates obtained from the diffusive phonon signals were compared with the results of the Baym-Ebner theory, and have also been used to calculate the coefficient of thermal conductivity in dilute 3 He- 4 He mixtures. (Auth.)

  10. Small-angle neutron polarization for the /sup 2/H(d vector,n vector)/sup 3/He reaction near Esub(d) = 8MeV

    Energy Technology Data Exchange (ETDEWEB)

    Tornow, W.; Woye, W.; Mack, G. (Tuebingen Univ. (Germany, F.R.). Physikalisches Inst.); Walter, R.L.; Floyd, C.E.; Guss, P.P.; Byrd, R.C. (Duke Univ., Durham, NC (USA). Dept. of Physics; Triangle Universities Nuclear Lab., Durham, NC (USA))

    1981-12-15

    Considerable improvement in the quality of analyzing power experiments performed with polarized fast neutrons has been achieved during the last few years by using neutrons from the polarization transfer reaction /sup 2/H(d vector,n vector)/sup 3/He at a reaction angle of theta = 0/sup 0/. To compromise in these experiments between intensity problems and finite geometry corrections, it is desirable in some instances to subtend a full-width angle ..delta..theta of 20/sup 0/ (lab) centered about theta = 0/sup 0/. In order to investigate the suitability of this reaction as a source of polarized neutrons for cases where the scatterer is close to the neutron source, the neutron polarization of the reaction /sup 2/H(d vector,n vector)/sup 3/He has been studied with ..delta..theta of about 3/sup 0/ in 3/sup 0/ steps out to theta = 20/sup 0/ (lab). An incident deuteron energy near 8 MeV was chosen to yield outgoing neutrons at 11.0 MeV, a typical energy for neutron analyzing power experiments. It is found that the effective neutron polarization, a combination of the two polarizations measured when the direction of the deuteron polarization is inverted or flipped at the polarized ion source, is large and nearly constant for angles between theta = 0/sup 0/ and theta = 10/sup 0/ (lab).

  11. Experimental Study of Photon Induced Reactions on 3He and 4He at Low Energies

    International Nuclear Information System (INIS)

    Tornow, W.

    2011-01-01

    Data are reported for the photodisintegration cross section of the reaction 3 He(γ, p) 2 H at ten energies between 7.0 and 16.0 MeV. Very preliminary data are presented for the reaction 4 He(γ, p) 3 H between 22.0 and 29.5 MeV in 0.5 MeV energy steps, and for the reaction 4 He(γ, n) 3 He at three energies around 28.0 MeV. High-pressure He/Xe gas scintillators served as target and detector. Our data are in better agreement with recent theoretical calculations than the majority of the existing data for all three reactions, but differ significantly from recent data taken with a mono-energetic photon beam and a time-projection chamber. (author)

  12. Backward elastic p3He-scattering and high momentum components of 3He wave function

    International Nuclear Information System (INIS)

    Uzikov, Yu.N.

    1998-01-01

    It is shown that owing to a dominance of np-pair transfer mechanism of backward elastic p 3 He-scattering for incident proton kinetic energies T p > 1 GeV the cross section of this process is defined mainly by the values of the Faddeev component of the wave function of 3 He nucleus, φ 23 (q 23 , p 1 ), at high relative momenta q 23 > 0.6 GeV/c of the NN-pair in the 1 S 0 -state and at low spectator momenta p 1 ∼ 0 - 0.2 GeV/c

  13. Specific heat of 4He and 3He--4He mixtures at their lambda transition

    International Nuclear Information System (INIS)

    Gasparini, F.M.; Moldover, M.R.

    1975-01-01

    We have measured the specific heat near the lambda transition of pure 4 He and of five 3 He-- 4 He mixtures up to a mole fraction of 0.39 3 He in 4 He. Our data for 4 He confirm the results of Ahlers revealing an asymmetry in the exponents above and below T/sub lambda/ when the specific heat is represented by a simple-power-law temperature dependence. Our results for these exponents (α = 0.012 plus-or-minus 0.002 and α' = -0.012 plus-or-minus 0.004) differ somewhat from Ahlers's. Our results can be reconciled with the requirement of scaling (α = α') only by supposing substantial contributions to C/sub p/ are made by singular correction terms to a simple power law. The measured specific heat of the mixtures richest in 3 He appears to be finite, continuous, and cusped at the lambda line. These qualitative features have been termed ''renormalization'' by Fisher. An analysis of our mixture data with a power-law temperature dependence does not yield a fully renormalized exponent, but rather an effective exponent. Derivatives at the lambda line were used to calculate the specific heat along paths of constant pressure and constant relative chemical potential.This specific heat behaves very much like C/sub p/ of pure 4 He, this behavior supporting the idea of universality for the specific-heat exponents. It is also true that the same asymmetry in the branches above and below T/sub lambda/ which is []bserved in pure 4 He is retained in the mixtures. The persistence of the asymmetry of C/subp//sub phi/ as one moves along the lambda line towards increasing 3 He concentration (at the saturated vapor pressure of the mixtures) is analogous to the persistence of the asymmetry of C/subp/ as one moves along the lambda line towards increasing pressure in pure 4 He

  14. Photodisintegration of 3H and 3He

    International Nuclear Information System (INIS)

    Faul, D.D.

    1980-09-01

    The photoneutron cross sections for 3 H and 3 He have been measured from threshold to approx. 25 MeV with monoenergetic photons from the annihilation in flight of fast positrons at the LLL Electron-Positron Linear Accelerator facility. These reactions include the two-body breakup of 3 H and the three-body breakup of both 3 H and 3 He; these measurements for 3 H are the first to span the energy region across the peaks of the cross sections. An efficient BF 3 -tube-and-paraffin neutron detector and high-pressure gaseous samples of several moles each (the activity of the 3 H sample was approx. 200,000 Ci) were employed in these measurements. Measurements on 16 O and 2 H also were performed to verify the absolute cross-section scale. The results, when compared with each other and with results for the two-body breakup cross section for 3 He from the literature, show that the two-body breakup cross sections for 3 H and 3 He have nearly the same shape, but the one for 3 He lies lower in magnitude; the three-body breakup cross section for 3 He lies higher in magnitude and is broader in the peak region and also rises less sharply from threshold than that for 3 H; and these measured differences between the cross sections for the breakup modes largely compensate in their sum, so that the total photon absorption cross sections for 3 H and 3 He are nearly the same in both size and shape at energies near and above their peaks. Theoretical results from the literature disagree with the experimental results to a certain extent over the entire photon-energy region for which the photoneutron cross sections were measured. 50 figures, 7 tables

  15. Quantum properties of spin polarized helium 3 optically oriented by a LNA laser

    International Nuclear Information System (INIS)

    Leduc, M.; Laloe, F.; Nacher, P.J.; Tastevin, G.; Daniels, J.M.; Betts, D.

    1986-01-01

    Spin polarized helium 3 (/sup 3/He increasing) and also atomic hydrogen (H decreasing) are systems exhibiting a number of unusual and interesting properties at low temperature. This is true even for dilute polarized gases in spite of the weakness of the nuclear magnetic interaction between atoms. The changes in the macroscopic properties of the gas with the nuclear polarization P are pure consequences of the indistinguishability of the particles and of the symmetrization principle in quantum mechanics. The transport properties of the gas, such as viscosity and thermal conductivity, have been calculated and found to be strongly dependent on P below a few kelvins. Spin transport in /sup 3/He increasing gives rise at low temperature to collective oscillatory modes: the transverse spin waves. Large changes are also expected with P in the case of more dense /sup 3/He fluids, such as an increase with P in the saturated vapor pressure. Optical pumping is a convenient technique for efficient polarization of the nuclear spins in /sup 3/He gas/sup 2/ making use of the 2/sup 3/S-2/sup 3/P atomic line at 1.08 μm. The arrival of cw tunable lasers in the near IR in the early 1980s gave a strong impulse to the buildup of experiments with a view to measuring quantum properties of /sup 3/He increasing at low temperature. Color center lasers (F/sup +//sub 2/ in NaF) provide P values up to 70%. They are now being replaced by more easy to handle LNA lasers which have given so far P in excess of 50% at room temperature. At low temperature, direct optical pumping of a /sup 3/He cell leads to poor P values; for that reason a different technique is used

  16. NUCLEON POLARIZATION IN 3-BODY MODELS OF POLARIZED LI-6

    NARCIS (Netherlands)

    SCHELLINGERHOUT, NW; KOK, LP; COON, SA; ADAM, RM

    1993-01-01

    Just as He-3 --> can be approximately characterized as a polarized neutron target, polarized Li-6D has been advocated as a good isoscalar nuclear target for the extraction of the polarized gluon content of the nucleon. The original argument rests upon a presumed ''alpha + deuteron'' picture of Li-6,

  17. A New Approach for High Pressure Pixel Polar Distribution on Off-line Signature Verification

    Directory of Open Access Journals (Sweden)

    Jesús F. Vargas

    2010-06-01

    Full Text Available Features representing information of High Pressure Points froma static image of a handwritten signature are analyzed for an offline verification system. From grayscale images, a new approach for High Pressure threshold estimation is proposed. Two images, one containingthe High Pressure Points extracted and other with a binary version ofthe original signature, are transformed to polar coordinates where a pixel density ratio between them is calculated. Polar space had been divided into angular and radial segments, which permit a local analysis of the high pressure distribution. Finally two vectors containing the density distribution ratio are calculated for nearest and farthest points from geometric center of the original signature image. Experiments were carried out using a database containing signature from 160 individual. The robustness of the analyzed system for simple forgeries is tested out with Support Vector Machines models. For the sake of completeness, a comparison of the results obtained by the proposed approach with similar works published is presented.

  18. Recent progress on HYSPEC, and its polarization analysis capabilities

    Directory of Open Access Journals (Sweden)

    Winn Barry

    2015-01-01

    Full Text Available HYSPEC is a high-intensity, direct-geometry time-of-flight spectrometer at the Spallation Neutron Source, optimized for measurement of excitations in small single-crystal specimens with optional polarization analysis capabilities. The incident neutron beam is monochromated using a Fermi chopper with short, straight blades, and is then vertically focused by Bragg scattering onto the sample position by either a highly oriented pyrolitic graphite (unpolarized or a Heusler (polarized crystal array. Neutrons are detected by a bank of 3He tubes that can be positioned over a wide range of scattering angles about the sample axis. HYSPEC entered the user program in February 2013 for unpolarized experiments, and is already experiencing a vibrant research program. Polarization analysis will be accomplished by using the Heusler crystal array to polarize the incident beam, and either a 3He spin filter or a supermirror wide-angle polarization analyser to analyse the scattered beam. The 3He spin filter employs the spin-exchange optical pumping technique. A 60∘ wide angle 3He cell that matches the detector coverage will be used for polarization analysis. The polarized gas in the post-sample wide angle cell is designed to be periodically and automatically refreshed with an adjustable pressure of polarized gas, optically pumped in a separate cell and then transferred to the wide angle cell. The supermirror analyser has 960 supermirror polarizers distributed over 60∘, and has been characterized at the Swiss Spallation Neutron Source. The current status of the instrument and the development of its polarization analysis capabilities are presented.

  19. 186Os and 187Os enrichments and high-3He/4He sources in the Earth's mantle

    DEFF Research Database (Denmark)

    Brandon, A.D.; Graham, D.W.; Waight, Tod Earle

    2007-01-01

    at present remains core-mantle interaction. While some plumes with high 3He/4He, such as Hawaii, appear to have been subjected to detectable addition of Os (and possibly He) from the outer core, others such as Iceland do not. A positive correlation between 187Os/188Os and 3He/4He from 9.6 to 19 Ra in Iceland...

  20. Application of the three-body model to the reactions 6Li(3He,t 3He)3He and 6Li(3He,3He3He)3H

    International Nuclear Information System (INIS)

    Haftel, M.I.; Allas, R.G.; Beach, L.A.; Bondelid, R.O.; Petersen, E.L.; Slaus, I.; Lambert, J.M.; Treado, P.A.

    1977-01-01

    Experimental and theoretical cross sections are presented for the 6 Li( 3 He, 3 He 3 He) 3 H and 6 Li( 3 He,t 3 He) 3 He reactions for the symmetric angle pairs 20 0 -20 0 , 28.3 0 -28.3 0 , and 35 0 -35 0 . The theoretical cross sections are calculated in a three-body model where the trions (i.e., mass-3 nuclei) are treated as elementary particles with 6 Li being a 3 He- 3 H bound state. The trion-trion interaction is represented by S wave separable potentials with the breakup cross sections calculated with the tree-body Haftel-Ebenhoeh code. the Coulomb interaction is taken into account by fitting the separable potential parameters to the trion-trion scattering data and is included approximately in the breakup code. The experimental cross sections are compared with both the plane-wave impulse approximation and the three-body model predictions. The plane-wave impulse approximation predicts both the shapes and magnitudes poorly (10 to 20 times experiment). Without Coulomb corrections the three-body model gives good agreement with experiment for the shapes of the spectra with the magnitudes generally being about 40% of experiment for 6 Li( 3 He, 3 He 3 He) 3 H and about 80% for 6 Li( 3 He,t 3 He) 3 He. The Coulomb corrections improve the magnitudes predicted by the three-body model but not the shapes. It is observed that for these reactions S wave separable potentials describe the breakup data much better than they do the two-body trion-trion scattering data. This result should encourage further three-body treatment of these and similar reactions

  1. Elastic scattering of polarized protons from 3He at intermediate energies

    International Nuclear Information System (INIS)

    Hasell, D.K.; Bracco, A.; Gubler, H.P.

    1982-09-01

    Using the polarized proton beam facility of the TRIUMF cyclotron, differential cross sections and analyzing powers have been measured in the angular range 20 0 - 150 0 c.m. for proton elastic scattering from 3 He at incident proton energies of 200, 300, 415 and 515 MeV. The differential cross sections exhibit a minimum at t = -0.33 (GeV/c) 2 which becomes more pronounced with increasing energy. There is evidence for the onset of a second minimum corresponding to the interference between double and triple scattering amplitudes. Large analyzing powers are observed at the lower energies. The data from the present analysis, together with data obtained from the literature in the energy range 100-1000 MeV, have been analyzed within the framework of the Glauber multiple scattering formalism. Nucleon-nucleon scattering parameters were taken from a global phase shift analysis of nucleon-nucleon elastic scattering data. Reasonable agreement with the data is obtained

  2. I. A model for the magnetic equation of state of liquid 3He. II. An induced interaction model for a two-component Fermi liquid

    International Nuclear Information System (INIS)

    Sanchez-Castro, C.R.

    1988-01-01

    This dissertation is divided in six chapters. Chapter 1 is an introduction to the rest of the dissertation. In it, the author presents the different models for the magnetic equation state of liquid 3 He, a derivation of the induced interaction equations for a one component Fermi liquid, and discuss the basic hamiltonian describing the heavy fermion compounds. In Chapter 2 and Chapter 3, he presents a complete discussion of the thermodynamics and Landau theory of a spin polarized Fermi liquid. A phenomenological model is then developed to predict the polarization dependence of the longitudinal Landau parameters in liquid 3 He. This model predicts a new magnetic equation of state and the possibility of liquid 3 He being 'nearly metamagnetic' at high pressures. Chapter 4 contains a microscopic calculation of the magnetic field dependence of the Landau parameters in a strongly correlated Fermi system using the induced interaction model. The system he studied consists of a single component Fermi liquid with parabolic energy bands, and a large on-site repulsive interaction. In Chapter 5, he presents a complete discussion of the Landau theory of a two component Fermi liquid. Then, he generalizes the induced interaction equations to calculate Landau parameters and scattering amplitudes for an arbitrary, spin polarized, two component Fermi liquid. The resulting equations are used to study a model for the heavy fermion Fermi liquid state: a two band electronic system with an antiferromagnetic interaction between the two bands. Chapter 6 contains the concluding remarks of the dissertation

  3. Optical Pumping Spin Exchange 3He Gas Cells for Magnetic Resonance Imaging

    Science.gov (United States)

    Kim, W.; Stepanyan, S. S.; Kim, A.; Jung, Y.; Woo, S.; Yurov, M.; Jang, J.

    2009-08-01

    We present a device for spin-exchange optical pumping system to produce large quantities of polarized noble gases for Magnetic Resonance Imaging (MRI). A method and design of apparatus for pumping the polarization of noble gases is described. The method and apparatus enable production, storage and usage of hyperpolarized noble gases for different purposes, including Magnetic Resonance Imaging of human and animal subjects. Magnetic imaging agents breathed into lungs can be observed by the radio waves of the MRI scanner and report back physical and functional information about lung's health and desease. The technique known as spin exchange optical pumping is used. Nuclear magnetic resonance is implemented to measure the polarization of hyperpolarized gas. The cells prepared and sealed under high vacuum after handling Alkali metals into the cell and filling with the 3He-N2 mixture. The cells could be refilled. The 3He reaches around 50% polarization in 5-15 hours.

  4. Comparison of analyzing power and polarization in the reaction 3H(p,n)3He. Pt. 2

    International Nuclear Information System (INIS)

    Tornow, W.; Byrd, R.C.; Lisowski, P.W.; Walter, R.L.; Donoghue, T.R.

    1981-01-01

    The polarization Psup(y) for the 3 H(p,n) 3 He reaction was measured for energies between 2 and 4 MeV. Special care was given to minimizing the effects of background and to interpreting the experimental spectra. The new values for Psup(y) are significantly higher than previous values, and comparison to the available data for the analyzing power Asub(y) for the same reaction now shows that in this energy range Psup(y) ad Asub(y) are equal within experimental uncertainties. This equality negates earlier conclusions that sizeable differences existed between these observables. In particular, our new results demonstrate that in this reaction the effects of charge symmetry breaking on differences between these observables must be small. (orig.)

  5. Polarized targets in high energy physics

    Energy Technology Data Exchange (ETDEWEB)

    Cates, G.D. Jr. [Princeton Univ., NJ (United States)

    1994-12-01

    Various approaches are discussed for producing polarized nuclear targets for high energy physics experiments. As a unifying theme, examples are drawn from experiments to measure spin dependent structure functions of nucleons in deep inelastic scattering. This single physics goal has, over roughly two decades, been a driving force in advances in target technology. Actual or planned approaches have included solid targets polarized by dynamic nuclear polarization (DNP), several types of internal targets for use in storage rings, and gaseous {sup 3}He targets polarized by spin-exchange optical pumping. This last approach is the type of target adopted for SLAC E-142, an experiment to measure the spin structure function of the neutron, and is described in detail.

  6. Polarized targets in high energy physics

    International Nuclear Information System (INIS)

    Cates, G.D. Jr.

    1994-01-01

    Various approaches are discussed for producing polarized nuclear targets for high energy physics experiments. As a unifying theme, examples are drawn from experiments to measure spin dependent structure functions of nucleons in deep inelastic scattering. This single physics goal has, over roughly two decades, been a driving force in advances in target technology. Actual or planned approaches have included solid targets polarized by dynamic nuclear polarization (DNP), several types of internal targets for use in storage rings, and gaseous 3 He targets polarized by spin-exchange optical pumping. This last approach is the type of target adopted for SLAC E-142, an experiment to measure the spin structure function of the neutron, and is described in detail

  7. Measurement of Double-Polarization Asymmetries in the Quasielastic He3→(e → ,e'd ) Process

    Science.gov (United States)

    Mihovilovič, M.; Jin, G.; Long, E.; Zhang, Y.-W.; Allada, K.; Anderson, B.; Annand, J. R. M.; Averett, T.; Boeglin, W.; Bradshaw, P.; Camsonne, A.; Canan, M.; Cates, G. D.; Chen, C.; Chen, J. P.; Chudakov, E.; De Leo, R.; Deng, X.; Deltuva, A.; Deur, A.; Dutta, C.; El Fassi, L.; Flay, D.; Frullani, S.; Garibaldi, F.; Gao, H.; Gilad, S.; Gilman, R.; Glamazdin, O.; Golak, J.; Golge, S.; Gomez, J.; Hansen, O.; Higinbotham, D. W.; Holmstrom, T.; Huang, J.; Ibrahim, H.; de Jager, C. W.; Jensen, E.; Jiang, X.; Jones, M.; Kang, H.; Katich, J.; Khanal, H. P.; Kievsky, A.; King, P.; Korsch, W.; LeRose, J.; Lindgren, R.; Lu, H.-J.; Luo, W.; Marcucci, L. E.; Markowitz, P.; Meziane, M.; Michaels, R.; Moffit, B.; Monaghan, P.; Muangma, N.; Nanda, S.; Norum, B. E.; Pan, K.; Parno, D.; Piasetzky, E.; Posik, M.; Punjabi, V.; Puckett, A. J. R.; Qian, X.; Qiang, Y.; Qui, X.; Riordan, S.; Saha, A.; Sauer, P. U.; Sawatzky, B.; Schiavilla, R.; Schoenrock, B.; Shabestari, M.; Shahinyan, A.; Širca, S.; Skibiński, R.; John, J. St.; Subedi, R.; Sulkosky, V.; Tobias, W. A.; Tireman, W.; Urciuoli, G. M.; Viviani, M.; Wang, D.; Wang, K.; Wang, Y.; Watson, J.; Wojtsekhowski, B.; Witała, H.; Ye, Z.; Zhan, X.; Zhang, Y.; Zheng, X.; Zhao, B.; Zhu, L.; Jefferson Lab Hall A Collaboration

    2014-12-01

    We present a precise measurement of double-polarization asymmetries in the He3→(e → ,e'd ) reaction. This particular process is a uniquely sensitive probe of hadron dynamics in 3He and the structure of the underlying electromagnetic currents. The measurements have been performed in and around quasielastic kinematics at Q2=0.25 (GeV /c )2 for missing momenta up to 270 MeV /c . The asymmetries are in fair agreement with the state-of-the-art calculations in terms of their functional dependencies on pm and ω , but are systematically offset. Beyond the region of the quasielastic peak, the discrepancies become even more pronounced. Thus, our measurements have been able to reveal deficiencies in the most sophisticated calculations of the three-body nuclear system, and indicate that further refinement in the treatment of their two-and/or three-body dynamics is required.

  8. Growth and dissolution of liquid 3He droplets in solid 4He matrix

    International Nuclear Information System (INIS)

    Gan'shin, A.N.; Grigor'ev, V.N.; Majdanov, V.A.; Penzev, A.A.; Rudavskij, Eh.Ya.; Rybalko, A.S.

    2000-01-01

    The phase separation kinetics of solid 3 He - 4 He mixtures was investigated using pressure measurements in the conditions when the two-phase system formed consists of concentrated phase liquid droplets (almost pure 3 He) in the dilute phase crystal matrix (almost pure 4 He). It is shown that the liquid droplet growth may be described by a sum of two exponential processes with small and large time contacts as cooling down step by step. This is a result of the strong influence of strains which appear in the crystal at the phase separation due to a large difference in molar volume between the phases and probably give rise to plastic deformation of the matrix and to non-equilibrium 3 He concentration in it. The 3 He atom transfer occurs only to the extent of strain relaxation. It is found that the cyclic growth and dissolution of the liquid droplets affect the crystal quality and lead to pressure increase. The coexistence of liquid and solid phases in droplets is speculated to be possible

  9. Setup and taking into operation of a highly sensitive 3He magnetometer for a future experiment for the determination of an electric dipole moment of the free neutron

    International Nuclear Information System (INIS)

    Kraft, Andreas

    2012-01-01

    The measurement of the electric dipole moment of the free neutron is directly linked to the question on the accurate determination of the magnetic field conditions inside the nEDM spectrometer. Using in-situ the spin-precession of polarized 3 He, monitored by optically pumped Cs-magnetometers a sensitivity on the femto-tesla-scale can be obtained. At the institute of physics of the University Mainz a 3 He/Cs-test facility was built to investigate the readout of 3 He-spin-precession with a lamp-pumped Cs-magnetometer. Additionally, an ultra-compact and transportable polarizer unit was developed and installed in Mainz, which polarizes 3 He gas up to 55 % of polarization before the compressed gas is delivered to two sandwich magnetometer cells inside the EDM chamber. This theses will present some results of the first successful test of the polarizer unit in January 2012. 3 He was polarized in the ultra compact polarizer unit and transferred via guiding fields into a 4 layer mu-metal shield, where the free spin precession was detected with a lamp pumped Cs-magnetometer.

  10. Dimerization of 3He in 3He-4He mixture films

    International Nuclear Information System (INIS)

    Bashkin, E.

    1994-01-01

    3 He atoms dissolved in superfluid 4 He may form dimers ( 3 He) 2 in two-dimensional geometries. Dimer formation is studied in films of dilute 3 He- 4 He mixture. After designing a schematic 3 He- 3 He interaction potential, the dimer binding energy is calculated for various substrates. It is shown that 3 He impurity states localized near the substrate give rise to the highest magnitudes of the binding energy. (author). 32 refs., 6 figs.,; 1 tab

  11. Setup and taking into operation of a highly sensitive {sup 3}He magnetometer for a future experiment for the determination of an electric dipole moment of the free neutron; Aufbau und Inbetriebnahme eines hochsensitiven {sup 3}He-Magnetometers fuer ein zukuenftiges Experiment zur Bestimmung eines elektrischen Dipolmoments des freien Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Kraft, Andreas

    2012-12-20

    The measurement of the electric dipole moment of the free neutron is directly linked to the question on the accurate determination of the magnetic field conditions inside the nEDM spectrometer. Using in-situ the spin-precession of polarized {sup 3}He, monitored by optically pumped Cs-magnetometers a sensitivity on the femto-tesla-scale can be obtained. At the institute of physics of the University Mainz a {sup 3}He/Cs-test facility was built to investigate the readout of {sup 3}He-spin-precession with a lamp-pumped Cs-magnetometer. Additionally, an ultra-compact and transportable polarizer unit was developed and installed in Mainz, which polarizes {sup 3}He gas up to 55 % of polarization before the compressed gas is delivered to two sandwich magnetometer cells inside the EDM chamber. This theses will present some results of the first successful test of the polarizer unit in January 2012. {sup 3}He was polarized in the ultra compact polarizer unit and transferred via guiding fields into a 4 layer mu-metal shield, where the free spin precession was detected with a lamp pumped Cs-magnetometer.

  12. Effective interactions in dilute mixtures of 3He in 4He

    International Nuclear Information System (INIS)

    Hsu, W.; Pines, D.

    1985-01-01

    Nonlocal pseudopotentials which describe the effective interaction between 3 He quasiparticles, and between these quasiparticles and the background 4 He liquid, are obtained as a function of concentration and pressure by generalizing the Aldrich--Pines pseudopotentials for pure 3 He and 4 He to dilute mixtures. The hierarchy of physical effects which determine these pseudopotentials is established. Interaction-induced short-range correlations are the dominant physical feature; next in order of importance is the greater zero point motion associated with the replacement of a 4 He atom by a 3 He atom, while spin-duced ''Pauli principle'' correlations play a significantly smaller, albeit still important role. We find a consistent trend in the change of the effective direct quasiparticle interactions with increasing concentration, and show how the Aldrich-Pines pseudopotentials for pure 3 He quasiparticles represent a natural extension of our results for dilute mixtures. Our calculated nonlocal pseudopotential for 3 He quasiparticles is qualitatively similar to that proposed by Bardeen, Baym, and Pines; it changes sign at somewhat lower momentum transfers than the BBP result, varies little with concentration, and provides a physical basis for understanding the BBP result. The effective interaction between quasiparticles of parallel spin, here determined for the first time, is essentially repulsive in the very dilute limit; as the concentration increases, it becomes increasingly attractive at low momentum transfers, and resembles closely that between antiparallel spin quasiparticles at 5% concentration. The concentration-dependent transport properties calculated from these pseudopotentials (which involve only one phenomenological parameter) are in good agreement with experiment at saturated vapor pressure (SVP), 10 atm, and 20 atm

  13. Anomalous perovskite PbRuO3 stabilized under high pressure

    Science.gov (United States)

    Cheng, J.-G.; Kweon, K. E.; Zhou, J.-S.; Alonso, J. A.; Kong, P.-P.; Liu, Y.; Jin, Changqing; Wu, Junjie; Lin, Jung-Fu; Larregola, S. A.; Yang, Wenge; Shen, Guoyin; MacDonald, A. H.; Manthiram, Arumugam; Hwang, G. S.; Goodenough, John B.

    2013-01-01

    Perovskite oxides ABO3 are important materials used as components in electronic devices. The highly compact crystal structure consists of a framework of corner-shared BO6 octahedra enclosing the A-site cations. Because of these structural features, forming a strong bond between A and B cations is highly unlikely and has not been reported in the literature. Here we report a pressure-induced first-order transition in PbRuO3 from a common orthorhombic phase (Pbnm) to an orthorhombic phase (Pbn21) at 32 GPa by using synchrotron X-ray diffraction. This transition has been further verified with resistivity measurements and Raman spectra under high pressure. In contrast to most well-studied perovskites under high pressure, the Pbn21 phase of PbRuO3 stabilized at high pressure is a polar perovskite. More interestingly, the Pbn21 phase has the most distorted octahedra and a shortest Pb—Ru bond length relative to the average Pb—Ru bond length that has ever been reported in a perovskite structure. We have also simulated the behavior of the PbRuO3 perovskite under high pressure by first principles calculations. The calculated critical pressure for the phase transition and evolution of lattice parameters under pressure match the experimental results quantitatively. Our calculations also reveal that the hybridization between a Ru:t2g orbital and an sp hybrid on Pb increases dramatically in the Pbnm phase under pressure. This pressure-induced change destabilizes the Pbnm phase to give a phase transition to the Pbn21 phase where electrons in the overlapping orbitals form bonding and antibonding states along the shortest Ru—Pb direction at P > Pc. PMID:24277807

  14. High pressure Moessbauer spectrometer for the high-resolution 93.3 keV resonance in 67Zn

    International Nuclear Information System (INIS)

    Adlassnig, W.; Potzel, W.; Moser, J.; Schaefer, C.; Steiner, M.; Kalvius, G.M.

    1989-01-01

    A high pressure, low temperature Moessbauer spectrometer for the high-resolution 93.3 keV resonance in 67 Zn is described. The pressure is generated by applying the opposed anvil technique. Using B 4 C anvils and a sandwich gasket quasihydrostatic pressures up to 6 GPa were obtained for the required large samples of 7 mm diameter and 2 mm thickness. The piezoelectric Doppler drive is mounted on top of the pressure clamp. The whole system can be cooled to liquid He temperatures. The spectrometer was used to investigate at 4.2 K the pressure dependence of the Moessbauer parameters of Zn metal. (orig.)

  15. Deep inelastic scattering of polarized electrons by polarized 3 He and the study of the neutron spin structure

    International Nuclear Information System (INIS)

    Arnold, R.G.; Bosted, P.E.; Dunne, J.; Fellbaum, J.; Keppel, C.; Rock, S.E.; Spengos, M.; Szalata, Z.M.; White, J.L.; Breton, V.; Fonvieille, H.; Roblin, Y.; Shapiro, G.; Hughes, E.W.; Borel, H.; Lombard-Nelsen, R.M.; Marroncle, J.; Morgenstern, J.; Staley, F.; Terrien, Y.; Anthony, P.L.; Dietrich, F.S.; Chupp, T.E.; Smith, T.; Thompson, A.K.; Kuhn, S.E.; Cates, G.D.; Middleton, H.; Newbury, N.R.; Anthony, P.L.; Gearhart, R.; Hughes, E.W.; Maruyama, T.; Meyer, W.; Petratos, G.G.; Pitthan, R.; Rokni, S.H.; Stuart, L.M.; White, J.L.; Woods, M.; Young, C.C.; Erbacher, R.; Kawall, D.; Kuhn, S.E.; Meziani, Z.E.; Holmes, R.; Souder, P.A.; Xu, J.; Meziani, Z.E.; Band, H.R.; Johnson, J.R.; Maruyama, T.; Prepost, R.; Zapala, G.

    1996-01-01

    The neutron longitudinal and transverse asymmetries A 1 n and A 2 n have been extracted from deep inelastic scattering of polarized electrons by a polarized 3 He target at incident energies of 19.42, 22.66 and 25.51 GeV. The measurement allows for the determination of the neutron spin structure functions g 1 n (x, Q 2 ) and g 2 n (x, Q 2 ) over the range 0.03 2 of 2 (GeV/c) 2 . The data are used for the evaluation of the Ellis-Jaffe and Bjorken sum rules. The neutron spin structure function g 1 n (x, Q 2 ) is small and negative within the range of our measurement, yielding an integral ∫ 0.03 0.6 g 1 n (x)dx - 0.028 ± 0.006 (stat) ± 0.006 (syst). Assuming Regge behavior at low x, we extract Γ 1 n ∫ 0 1 g 1 n (x)dx = - 0.031 ± 0.006 (stat) ± 0.009 (syst). Combined with previous proton integral results from SLAC experiment E143, we find Γ 1 p - Γ 1 n = 0.160 ± 0.015 in agreement with the Bjorken sum rule prediction Γ 1 p - Γ 1 p 0.176 ± 0.008 at a Q 2 value of 3 (GeV/c) 2 evaluated using α s 0.32 ± 0.05. (authors)

  16. Measurement of the deuteron tensor polarization at the sup 3 He->d+p vertex up to internal momenta of 0.43 GeV/c

    CERN Document Server

    Sitnik, I M; Tomasi-Gustafsson, E; Azhgirey, L S; Ball, J; Bimbot, L; Bisson, Y; Boivin, M; Borzunov, Yu T; Boyard, J L; Courtat, P; Gacougnolle, R; Garçon, M; Golovanov, L B; Hennino, T; Jones, M; Kirillov, D A; Kunne, Ronald Alexander; Malinina, L V; Nedev, S; Piskunov, N M; Punjabi, V; Rekalo, M P; Sans, J L; Skowron, R; Strokovsky, E A; Yonnet, J

    2000-01-01

    The tensor polarization of deuterons, rho sub 2 sub 0 , emitted at zero degree in the sup 1 H( sup 3 He, d-reversible)X reaction, was measured at the Saturne National Laboratory in Saclay, using the SPES4 magnetic channel and the HYPOM polarimeter. The momentum of the detected deuterons was kept fixed at 3.77 GeV/c, while the momentum of the sup 3 He beam was varied from 5.66 to 4.60 GeV/c; this provided a range of internal momenta of a deuteron in sup 3 He, k, from 0 to 0.43 GeV/c.

  17. Electron emission in the Auger neutralization of a spin-polarized He+ ion embedded in a free electron gas

    International Nuclear Information System (INIS)

    Juaristi, J.I.; Alducin, M.; Diez Muino, R.; Roesler, M.

    2005-01-01

    Results are presented for the energy distribution and spin polarization of the electrons excited during the Auger neutralization of a spin polarized He + ion embedded in a paramagnetic free electron gas. The screening of the He + ion is calculated using density functional theory within the local spin density approximation. The Auger rates, the energy distribution and the spin polarization of the excited electrons are obtained using the Fermi golden rule. The transport of the electrons is calculated within the Boltzmann transport equation formalism. The spin-polarization of the initially excited electrons is very high (>70%) and parallel to that of the electron bound to the He + ion. Nevertheless, the emitted electrons show a much lower degree of polarization, mainly in the low energy range, due to the creation of the unpolarized cascade of secondaries in the transport process

  18. Coupling between Solid 3He on Aerogel and Superfluid 3He in the Low Temperature Limit

    International Nuclear Information System (INIS)

    Bradley, D. I.; Fisher, S. N.; Guenault, A. M.; Haley, R. P.; Pickett, G. R.; Tsepelin, V.; Whitehead, R. C. V.; Skyba, P.

    2006-01-01

    We have cooled liquid 3He contained in a 98% open aerogel sample surrounded by bulk superfluid 3He-B at zero pressure to below 120 μK. The aerogel sample is placed in a quasiparticle blackbody radiator cooled by a Lancaster-style nuclear cooling stage to ∼200 μK. We monitor the temperature of the 3He inside the blackbody radiator using a vibrating wire resonator. We find that reducing the magnetic field on the aerogel sample causes substantial cooling of all the superfluid inside the blackbody radiator. We believe this is due to the demagnetization of the solid 3He layers on the aerogel strands. This system has potential for achieving extremely low temperatures in the confined fluid

  19. Bound states of 3He in 3He-4He mixture films

    International Nuclear Information System (INIS)

    Bashkin, E.; Pavloff, N.; Treiner, J.

    1995-01-01

    3 He atoms dissolved in superfluid 4 He may form dimers ( 3 He) 2 in two-dimensional (2D) geometries. We study dimer formation in films of dilute 3 He- 4 He mixture. After designing a schematic 3 He- 4 He interaction potential we calculate the dimer binding energy for various substrates. It is shown that 3 He impurity states localized near the substrate give rise to the largest magnitudes of the binding energies

  20. Efficient 3He/4He separation in a nanoporous graphenylene membrane.

    Science.gov (United States)

    Qu, Yuanyuan; Li, Feng; Zhao, Mingwen

    2017-08-16

    Helium-3 is a precious noble gas, which is essential in many advanced technologies such as cryogenics, isotope labeling and nuclear weapons. The current imbalance of 3 He demand and supply shortage leads to the search for an efficient membrane with high performance for 3 He separation. In this study, based on first-principles calculations, we demonstrated that highly efficient 3 He harvesting can be achieved in a nanoporous graphenylene membrane with industrially-acceptable selectivity and permeance. The quantum tunneling effect leads to 3 He harvesting with high efficiency via kinetic sieving. Both the quantum tunneling effect and zero-point energy (ZPE) determine the 3 He/ 4 He separation via thermally-driven equilibrium sieving, where the ZPE effect dominates efficient 3 He/ 4 He separation between two reservoirs. The quantum effects revealed in this work suggest that the nanoporous graphenylene membrane is promising for efficient 3 He harvesting that can be exploited for industrial applications.

  1. Observation of the Rotational Spectra of 4HeH+, 4HeD+, 3HeH+, and 3HeD+

    International Nuclear Information System (INIS)

    Matsushima, F.; Oka, T.; Takagi, K.

    1997-01-01

    Low J rotational transitions of 4 HeH + , 4 HeD + , 3 HeH + , and 3 HeD + were observed in the 2 endash 5THz region with a high-precision far-infrared spectrometer. Dunham coefficients Y kl and isotopically independent parameters U kl , Δ He kl , and Δ H kl were determined. In particular, Δ parameters with k=0 and l=1,2 were determined with unprecedented accuracy, and provide important information for breakdown of the Born-Oppenheimer approximation. The lowest J=1 left-arrow 0 transition of 4 HeH + observed at 2010.1839(2)GHz will be an important future probe for detecting this species in space. copyright 1997 The American Physical Society

  2. Measurement of the Neutron (3He) Spin Structure at Low Q2 and the Extended Gerasimov-Drell-Hearn Sum Rule

    Energy Technology Data Exchange (ETDEWEB)

    Kominis, Ioannis [Princeton Univ., NJ (United States)

    2001-01-01

    This thesis presents the results of E-94010, an experiment at Thomas Jefferson National Accelerator Facility (TJNAF) designed to study the spin structure of the neutron at low momentum transfer, and to test the “extended” Gerasimov-Drell-Hearn (GDH) sum rule. The first experiment of its kind, it was performed in experimental Hall-A of TJNAF using a new polarized 3He facility. It has recently been shown that the GDH sum rule and the Bjorken sum rule are both special examples of a more general sum rule that applies to polarized electron scattering off nucleons. This generalized sum rule, due to Ji and Osborne, reduces to the GDH sum rule at Q2 = 0 and to the Bjorken sum rule at Q2 >> 1 GeV2. By studying the Q2 evolution of the extended GDH sum, one learns about the transition from quark-like behavior to hadronic-like behavior. We measured inclusive polarized cross sections by scattering high energy polarized electrons off the new TJNAF polarized 3He target with both longitudinal and transverse target orientations. The high density 3He target, based on optical pumping and spin exchange, was used as an effective neutron target. The target maintained a polarization of about 35% at beam currents as high as 151tA. We describe the precision 3He polarimetry leading to a systematic uncertainty of the target polarization of 4% (relative). A strained GaAs photocathode was utilized in the polarized electron gun, which provided an electron beam with a polarization of about 70%, known to 3% (relative). By using six different beam energies (between 0.86 and 5.06 GeV) and a fixed scattering angle of 15.5°, a wide kinematic coverage was achieved, with 0.02 GeV2< Q2 <1 GcV2 and 0.5 GeV< W < 2.5 GeV for the squared momentum transfer and invariant mass, respectively. From the measured cross sections we extract the 3He spin structure functions g$3 He

  3. The Precision Measurement of the Neutron Spin Structure Function Using Polarized HE-3 Target

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X

    2004-01-05

    Using a 48.6 GeV polarized electron beam scattering off a polarized {sup 3}He target at Stanford Linear Accelerator Centre (SLAC), they measured the neutron spin structure function g{sub 1}{sup n} over kinematic(x) ranging 0.014 < x <0.7 and 1 < Q{sup 2} < 17GeV{sup 2}. The measurement gave the integral result over the neutron spin structure function {integral}{sub 0.014}{sup 0.7} g{sub 1}{sup n}(x)dx = -0.036 {+-} 0.004(stat) {+-} 0.005(syst) at an average Q{sup 2} = 5GeV{sup 2}. Along with the proton results from SLAC E143 experiment (0.03 < x) and SMC experiment (0.014 < x < 0.03), they find the Bjorken sum rule appears to be largely saturated by the data integrated down to x of 0.014. However, they observe relatively large values for g{sub 1}{sup n} at low x. The result calls into question the usual methods (Regge theory) for extrapolating to x = 0 to find the full neutron integral {integral}{sub 0}{sup t} g{sub 1}{sup n}(x) dx, needed for testing the Quark-Parton Model (QMP).

  4. A novel polarization demodulation method using polarization beam splitter (PBS) for dynamic pressure sensor

    Science.gov (United States)

    Su, Yang; Zhou, Hua; Wang, Yiming; Shen, Huiping

    2018-03-01

    In this paper we propose a new design to demodulate polarization properties induced by pressure using a PBS (polarization beam splitter), which is different with traditional polarimeter based on the 4-detector polarization measurement approach. The theoretical model is established by Muller matrix method. Experimental results confirm the validity of our analysis. Proportional relationships and linear fit are found between output signal and applied pressure. A maximum sensitivity of 0.092182 mv/mv is experimentally achieved and the frequency response exhibits a <0.14 dB variation across the measurement bandwidth. The sensitivity dependence on incident SOP (state of polarization) is investigated. The simple and all-fiber configuration, low-cost and high speed potential make it promising for fiber-based dynamic pressure sensing.

  5. Study of the short-range 3He structure from the dd→3Hen reaction

    International Nuclear Information System (INIS)

    Ladygin, V.P.; Ladygina, N.V.

    1995-01-01

    An experiment on studying of the tensor analysing power C 0,NN,0,0 and spin correlation C N,N,0,0 due to the transverse polarization of both initial particles from the dd→ 3 Hen reaction has been proposed. Those polarization observables are very sensitive to the short-range 3 He structure. This experiment is proposed to be done at the LHE Accelerator Complex using both a polarized deuteron beam and a polarized deuterium target. 25 refs., 2 figs

  6. HE3 outgassing from four working palladium and uranium beds

    International Nuclear Information System (INIS)

    Souers, P. C.; Coronado, P. R.; Fearon, F. M.; Garza, R. G.; Shaw , J. F.; Stump, R. K.; Tsugawa, R. T.

    1988-01-01

    The He 3 output from two palladium and two uranium beds storing T 2 and D-T was studied as a function of time. Three of the beds were started new and watched for a year; the fourth bed was twelve years old. All four were beds used in routine tritium handling. Initial stoichiometries were PdT/sub 0.3/ and UT/sub 0.7/ so that both operated at similar 1 to 130 kPa pressures. The He 3 from palladium ranged from the 0.002 mo1% lower level of sensitivity to 0.01% for PdT 2 at one year of age. The UT system showed 0.1% He 3 at 4 to 62 days and 0.1 to 10% at longer times, with the first cuts being high in He 3 . The palladium bed with 95 to 97% pure T 2 enriches the output to as high as 97 to 99%. 9 refs., 1 fig., 2 tabs

  7. Differential osmotic pressure measurements of the concentration susceptibility of liquid 3He/4He mixtures near the lambda curve and tricritical point

    International Nuclear Information System (INIS)

    Gearhart, C.A. Jr.; Zimmermann, W. Jr.

    1979-01-01

    Values of the concentration susceptibility (partial x/partial Δ)/sub T/,P of liquid 3 He/ 4 He mixtures have been determined near the lambda curve and tricritical point from measurements of the differential osmotic pressure as a function of temperature T at four values of the 3 He mole fraction, x = 0.594, x = 0.644, x = 0.680, and x = 0.706. Here Δ = μ 3 - μ 4 is the difference between molar chemical potentials and P is the pressure. Our results for the two values of x less than the tricritical value x/sub t/ = 0.675 show pronounced peaks at the lambda transition. For 3 x 10 -4 -2 , where t equals [T - T/sub lambda/(x)]/T/sub lambda/(x), these peaks may be characterized both above and below the transition by the form (A/sub plus-or-minus//α/sub plus-or-minus/) (vertical-bart vertical-bar/sup -alpha/ +- - 1) + B/sub plus-or-minus/, with exponents α/sub plus-or-minus/ lying in the range from approx. 0.0 to approx. 0.2. Except perhaps for x -1 [T-T/sub t//T/sub t/)/vertical-barx-x/sub t//x/sub t/vertical-bar], where f and Ψ are functions determined by experiment and T/sub t/ = 0.867 K is the tricritical value of T. With the aid of this scaling relationship, the behavior of (partialx/partialΔ)/sub T/,P along curves of constant Δ near the lambda curve has been constucted from our data at constant x

  8. Sequential double photodetachment of He- in elliptically polarized laser fields

    Science.gov (United States)

    Génévriez, Matthieu; Dunseath, Kevin M.; Terao-Dunseath, Mariko; Urbain, Xavier

    2018-02-01

    Four-photon double detachment of the helium negative ion is investigated experimentally and theoretically for photon energies where the transient helium atom is in the 1 s 2 s 3S or 1 s 2 p P3o states, which subsequently ionize by absorption of three photons. Ionization is enhanced by intermediate resonances, giving rise to series of peaks in the He+ spectrum, which we study in detail. The He+ yield is measured in the wavelength ranges from 530 to 560 nm and from 685 to 730 nm and for various polarizations of the laser light. Double detachment is treated theoretically as a sequential process, within the framework of R -matrix theory for the first step and effective Hamiltonian theory for the second step. Experimental conditions are accurately modeled, and the measured and simulated yields are in good qualitative and, in some cases, quantitative agreement. Resonances in the double detachment spectra can be attributed to well-defined Rydberg states of the transient atom. The double detachment yield exhibits a strong dependence on the laser polarization which can be related to the magnetic quantum number of the intermediate atomic state. We also investigate the possibility of nonsequential double detachment with a two-color experiment but observe no evidence for it.

  9. Towards the observation of the magnetic structure of solid 3He

    International Nuclear Information System (INIS)

    Rufin, D.

    1982-03-01

    Experiments involving neutron scattering by 3 He for which thermalization problems have been solved, along with the development of novel measurement techniques (density, magnetization, temperature) by polarized neutron transmission, crystallization experiments with 3 He and 4 He: a single crystal of helium have been obtained within a sintered metal in which the pore size is less than a micron are presented [fr

  10. Measurement of the hyperfine structure of the ground state of muonic helium(3)

    International Nuclear Information System (INIS)

    Arnold, K.P.

    1984-01-01

    Polarization measurements by the muon spin rotation method yielded the detection that in the formation of 3 Heμ - e - the hfs states are occupied differently. In pure helium(3) a residual polarization of 2.6(4)% of the ( 3 Heμ - ) + ion was found. At an admixture of 2% xenon the neutral 3 Heμ - e - atom is formed with a polarization of 1.8(4)%. The hfs measurements were performed by means of the high-frequency spectroscopy. By inducing of Δmsub(F)=+-1 transitions the muon polarization is changed. This effects a change of the asymmetric electron distribution which arises by the parity-violating muon decay and can be detected by plastic scintillators. The measurements were performed at a highly pure gas target of 19.90 bar helium(3) to which 1.6% Xe were admixed, at 20 0 C and in a magnetic zero field. The pressure shift for the hfs measurements of 3 Heμ - e - , extrapolated to the buffer gas pressure zero, is: Δνsub(hfs)=4166.41(5) MHz. (orig./HSI) [de

  11. High-pressure {sup 4}He drift tubes for fissile material detection

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhehui, E-mail: zwang@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Morris, Christopher L. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Gray, F.E. [Regis University, Denver, CO 80221 (United States); Bacon, J.D.; Brockwell, M.I.; Chang, D.Y.; Chung, K.; Dai, W.G.; Greene, S.J.; Hogan, G.E.; Lisowski, P.W.; Makela, M.F.; Mariam, F.G.; McGaughey, P.L. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Mendenhall, M. [California Institute of Technology, Pasadena, CA 91125 (United States); Milner, E.C.; Miyadera, H.; Murray, M.M.; Perry, J.O.; Roybal, J.D. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); and others

    2013-03-01

    A detector efficiency model based on energy extraction from neutrons is described and used to compare {sup 4}He detectors with liquid scintillators (EJ301/NE-213). Detector efficiency can be divided into three regimes: single neutron scattering, multiple neutron scattering, and a transition regime in-between. For an average fission neutron of 2 MeV, the amount of {sup 4}He needed would be about 1/4 of the amount of the mass of EJ301/NE-213 in the single-scattering regime. For about 50% neutron energy extraction (1 MeV out of 2 MeV), the two types of detectors ({sup 4}He in the transition regime, EJ301 still in the single-scattering regime) have comparable mass, but {sup 4}He detectors can be much larger depending on the number density. A six-tube 11-bar-pressure {sup 4}He detector prototype is built and tested. Individual electrical pulses from the detector are recorded using a 12-bit digitizer. Differences in pulse rise time and amplitudes, due to different energy loss of neutrons and gamma rays, are used for neutron/gamma separation. Several energy spectra are also obtained and analyzed.

  12. Comparison of analyzing power and polarization in the reaction /sup 3/H(p,n)/sup 3/He. Pt. 2. New polarization results below 4 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Tornow, W.; Byrd, R.C.; Lisowski, P.W.; Walter, R.L. (Duke Univ., Durham, NC (USA). Dept. of Physics; Triangle Universities Nuclear Lab., Durham, NC (USA)); Donoghue, T.R. (Ohio State Univ., Columbus (USA). Dept. of Physics)

    1981-11-30

    The polarization Psup(y) for the /sup 3/H(p,n)/sup 3/He reaction was measured for energies between 2 and 4 MeV. Special care was given to minimizing the effects of background and to interpreting the experimental spectra. The new values for Psup(y) are significantly higher than previous values, and comparison to the available data for the analyzing power Asub(y) for the same reaction now shows that in this energy range Psup(y) ad Asub(y) are equal within experimental uncertainties. This equality negates earlier conclusions that sizeable differences existed between these observables. In particular, our new results demonstrate that in this reaction the effects of charge symmetry breaking on differences between these observables must be small.

  13. The 3He spectral function in light-front dynamics

    Directory of Open Access Journals (Sweden)

    Rinaldi Matteo

    2016-01-01

    Full Text Available A distorted spin-dependent spectral function for 3He is considered for the extraction of the transverse-momentum dependent parton distributions in the neutron from semi-inclusive deep inelastic electron scattering off polarized 3He at finite momentum transfers, where final state interactions are taken into account. The generalization of the analysis to a Poincaré covariant framework within the light-front dynamics is outlined.

  14. Competition and coexistence of polar and non-polar states in Sr1-x Ca x TiO3: an investigation using pressure dependent Raman spectroscopy

    Science.gov (United States)

    Tyagi, Shekhar; Sharma, Gaurav; Sathe, Vasant G.

    2018-03-01

    The competition and cooperation between ferroelectric and anti-ferro-distortion (AFD) instabilities are studied using pressure dependent Raman spectroscopy on polycrystalline powder samples of Sr1-x Ca x TiO3(x  =  0.0, 0.06, 0.25, 0.35). For x  =  0.0 composition, a broad polar mode is detected in the Raman spectra above 6 GPa, while for x  =  0.06 composition, the polar modes appear well above 9 GPa where the AFD modes showed strong suppression. In x  =  0.25 and 0.35 composition, the application of small pressure resulted in the appearance of strong AFD modes suppressing the polar modes. At elevated pressures, re-entrant polar modes are observed along with the broad AFD modes and some new peaks are also observed, signifying the lowering of local symmetry. The reappearance of polar modes is found to be related to pressure induced symmetry disorder at local level, suggesting its electronic origin. The re-entrant polar modes observed at higher pressure values are found to be significantly broad and asymmetric in nature, signifying the development of ferroelectric micro regions/nano domains coexisting with AFD. The lower symmetry at local length scale provides a conducive atmosphere for coexisting AFD and FE instabilities.

  15. Large-space cluster model calculations for the 3He(3He,2p)4He and 3H(3H,2n)4He reactions

    International Nuclear Information System (INIS)

    Csoto, Attila; Langanke, Karlheinz

    1999-01-01

    The 3 He( 3 He, 2p) 4 He and 3 H( 3 H, 2n) 4 He reactions are studied in a microscopic cluster model. We search for resonances in the 3 He+ 3 He and 4 He + p + p channels using methods that treat the two- and three-body resonance asymptotics correctly. Our results show that the existence of a low-energy resonance or virtual state, which could influence the 7 Be and 8 B solar neutrino fluxes, is rather unlikely. Our calculated 3 He( 3 He, 2p) 4 He and 3 H( 3 H, 2n) 4 He cross sections are in a good general agreement with the experimental data

  16. He 3 -Xe 129 Comagnetometery using Rb 87 Detection and Decoupling

    Science.gov (United States)

    Limes, M. E.; Sheng, D.; Romalis, M. V.

    2018-01-01

    We describe a He 3 -Xe 129 comagnetometer using Rb 87 atoms for noble-gas spin polarization and detection. We use a train of Rb 87 π pulses and σ+/σ- optical pumping to realize a finite-field Rb magnetometer with suppression of spin-exchange relaxation. We suppress frequency shifts from polarized Rb by measuring the He 3 and Xe 129 spin precession frequencies in the dark, while applying π pulses along two directions to depolarize Rb atoms. The plane of the π pulses is rotated to suppress the Bloch-Siegert shifts for the nuclear spins. We measure the ratio of He 3 to Xe 129 spin precession frequencies with sufficient absolute accuracy to resolve Earth's rotation without changing the orientation of the comagnetometer. A frequency resolution of 7 nHz is achieved after integration for 8 h without evidence of significant drift.

  17. 3He and chlorofluorocarbons (CFC) in the Southern Ocean

    International Nuclear Information System (INIS)

    Jean-Baptiste, P.; Jamous, D.; Mantisi, F.; Memery, L.; Universite Paris 6

    1991-01-01

    The distribution of 3 He across the Southern Ocean is depicted on the basis of a meridional section between Antarctica and South Africa measured during the INDIGO-3 survey (1988). A core of δ 3 He values above 10% is observed south of the Polar Front, associated with very low CFC concentrations. This 3 He enriched layer is documented from the GEOSECS and INDIGO 3 He data in the Southern Ocean. It is found at a density level around θ σ =27.8 in all the waters close to Antarctica (i.e. south of 50 degS). Its zonal distribution suggests that it is likely that it originates from the central/eastern Pacific. Hence, it provides an indication of the deep Pacific waters in the Antarctic Circumpolar Current, which are not easily detectable from the standard hydrographic parameters. (author). 19 refs.; 8 figs

  18. Nonlinear second- and first-sound wave equations in 3He-4He mixtures

    International Nuclear Information System (INIS)

    Mohazzab, Masoud; Mulders, Norbert

    2000-01-01

    We derive nonlinear Burgers equations for first and second sound in mixtures of 3 He- 4 He, using a reductive perturbation method and obtain expressions for the nonlinear and dissipation coefficients. We further find a diffusion equation for a coupled temperature-concentration mode. The amplitude of first (second) sound generated from second (first) sound in mixtures is also derived. Our derivation includes the dependence of thermodynamical quantities on temperature, pressure, and 3 He concentration, and is valid up to a first order in terms of the isobaric expansion coefficient. We show that close to the λ line the nonlinearity of second sound in mixtures is enhanced as compared with pure 4 He

  19. The polarization of a 29 MeV beam of 3{sup H}e particles scattered by C, Al, Cu, Sn, and Au; Estudio de la polarizacion producida en un Haz de 3{sup H}e de 29 de MeV por C, Al, Cu, Sn, y Au

    Energy Technology Data Exchange (ETDEWEB)

    Perez Dominguez, J M

    1964-07-01

    A series of 3{sup H}e polarization measurements has been carried out by means of double scattering experiments, in which 29 MeV 3{sup H}e particles were elastically scattered gist from carbon, aluminium, copper, tin or gold, il fork K1 nuclear plates were used as detector. The most important feature in the carbon polarization is the broad maxima in the interval from 30 degree centigrade to 40 degree centigrade (C.M.). Important asymmetries were also found for aluminium. Small asymmetries were found for copper and thin, in the angular interval covered by our experiment. Our experimental results show only very small asymmetries fro gold up to 50 degree centigrade C. M. (Author) 9 refs.

  20. Development of 3He-BOCA power ramping facility, 1

    International Nuclear Information System (INIS)

    Nakata, Hirokatsu; Ishii, Tadahiko; Itoh, Haruhiko; Abe, Hiroshi; Nakazaki, Chozaburo

    1979-11-01

    Development of a He-3 power controlled boiling water capsule, 3 He-BOCS, for LWR fuels power ramping test in JMTR has been carried out since 1978 on a five-year program; in the reactor, irradiation tests of various fuels and structual materials have been made since 1969. Using stagnant-pressurized water as a thermal medium, the capsule provides pressure and temperature conditions similar to those in LWRs. Heat generation of a fuel pin can be controlled by a He-3 gas screen surrounding the capsule. The facility is capable of testing numbers of both fresh and irradiated fuel pins under LWR operating conditions for power ramping and cycling. After explaining the operating priciples of 3 He-BOCA and the development program, the following are described: the results of preliminary out-of-pile test on heat conductive characteristics of the capsule and a conceptual design of the 3 He-BOCA for power ramping of a short fuel pin from 250 W/cm to 500 W/cm under BWR conditions. (author)

  1. Infrared spectra of 4HeH+, 4HeD+, 3HeH+, and 3HeD+

    International Nuclear Information System (INIS)

    Crofton, M.W.; Altman, R.S.; Haese, N.N.; Oka, T.

    1989-01-01

    Isotopic species of the HeH + molecular ion provide an excellent testing ground for studying isotopic dependence of vibration--rotation constants because of the small masses of He and H isotopes. We have observed infrared spectra of the hot band v=2 left-arrow 1 of HeH + and fundamental bands of isotopic species HeD + , 3 HeH + , and 3 HeD + , and obtained the Dunham coefficients Y kl , and the isotopically independent parameters U kl , Δ He kl , and Δ H kl

  2. NMR and superfluidity of 3He in 3He-4He solutions

    International Nuclear Information System (INIS)

    Ivanova, K.D.; Mejerovich, A.Eh.

    1986-01-01

    Two possibilities of determining the superfluid transition temperature for 3 He in a 3 He- 4 He solution by the NMR technique are discussed. One of the methods consists in measuring the spin diffusion coefficient in weak magnetic fields at ultralow temperatures, and the other in measuring the ratio of the spin diffusion coefficient to the spin wave absorption coefficient at not very low temperatures. The transition temperature is estimated on the basis of the available experimental data. The effect of the superfluid transition in a system of 3 He quasiparticles on the propagation of transverse spin waves and longitudinal spin-sound oscillations in 3 He- 4 He solutions is studied. It is shown that there is a range of weak magnetic field intensities restricted from both sides in which the propagation of weakly damped spin-sound waves is possible

  3. The effects of polarized light therapy in pressure ulcer healing.

    Science.gov (United States)

    Durović, Aleksandar; Marić, Dragan; Brdareski, Zorica; Jevtić, Miodrag; Durdević, Slavisa

    2008-12-01

    Neglecting polarized light as an adjuvant therapy for pressure ulcers and methodology distinctions in the trials engaging polarized light are the reasons for many dilemmas and contradictions. The aim of this study was to establish the effects of polarized light therapy in pressure ulcer healing. This prospective randomized single-blind study involved 40 patients with stage I-III of pressure ulcer. The patients in the experimental group (E) were subjected, besides polarized light therapy, to standard wound cleaning and dressing. Standard wound cleaning and dressing were the only treatment used in the control group (C). A polarized light source was a Bioptron lamp. Polarized light therapy was applied for six min daily, five times a week, four weeks. The Pressure Ulcer Scale for Healing (PUSH) was used in the assessment of outcome. Statistic analysis included Mann Whitney Test, Fisher Exact Test, Wilcoxon Signed Rank test. There were significant differences between the groups at the end of the treatment regarding the surface of pressure ulcer (E: 10.80 +/- 19.18; C: 22,97 +/- 25,47; p = 0.0005), rank of pressure ulcer (E: 5.90 +/- 2.48; C: 8.6 +/- 1.05; p = 0.0005) and total PUSH score (E: 7.35 +/- 3.17; C: 11.85 +/- 2.35; p = 0,0003). The patients in the experimental group had significantly better values of the parameters monitored than the patients in the control group. After a four-week polarized light therapy 20 patients with stage I-III ulcer had significant improvement in pressure ulcer healing, so it could be useful to apply polarized light in the treatment of pressure ulcers.

  4. Deep inelastic scattering of polarized electrons by polarized {sup 3} He and the study of the neutron spin structure

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, R G; Bosted, P E; Dunne, J; Fellbaum, J; Keppel, C; Rock, S E; Spengos, M; Szalata, Z M; White, J L [Washington State Univ., Pullman, WA (United States); Breton, V; Fonvieille, H; Roblin, Y [Clermont-Ferrand-2 Univ., 63 - Aubiere (France); Shapiro, G [Lawrence Berkeley Lab., CA (United States); Hughes, E W [California Inst. of Tech., Pasadena, CA (United States); Borel, H; Lombard-Nelsen, R M; Marroncle, J; Morgenstern, J; Staley, F; Terrien, Y [CEA Centre d` Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. d` Astrophysique, de la Physique des Particules, de la Physique Nucleaire et de l` Instrumentation Associee; Petratos, G G [Kent State Univ., OH (United States); Anthony, P L; Dietrich, F S [Lawrence Livermore National Lab., CA (United States); Chupp, T E; Smith, T [Michigan Univ., Dearborn, MI (United States); Thompson, A K [National Inst. of Standards and Technology, Gaithersburg, MD (United States); Kuhn, S E [Norfolk State Univ., VA (United States); Cates, G D; Middleton, H; Newbury, N R [Princeton Univ., NJ (United States); Anthony, P L; Gearhart, R; Hughes, E W; Maruyama, T; Meyer, W; Petratos, G G; Pitthan, R; Rokni, S H; Stuart, L M; White, J L; Woods, M; Young, C C [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Erbacher, R; Kawall, D; Kuhn, S E; Meziani, Z E [Stanford Univ., CA (United States); Holmes, R; Souder, P A; Xu, J [Syracuse Univ., NY (United States); Meziani, Z E [Temple Univ., Philadelphia, PA (United States); Band, H R; Johnson, J R; Maruyama, T; Prepost, R; Zapala, G [Wisconsin Univ., Madison, WI (United States)

    1997-12-31

    The neutron longitudinal and transverse asymmetries A{sub 1}{sup n} and A{sub 2}{sup n} have been extracted from deep inelastic scattering of polarized electrons by a polarized {sup 3}He target at incident energies of 19.42, 22.66 and 25.51 GeV. The measurement allows for the determination of the neutron spin structure functions g{sub 1}{sup n}(x, Q{sup 2}) and g{sub 2}{sup n} (x, Q{sup 2}) over the range 0.03 < x < 0.6 at an average Q{sup 2} of 2 (GeV/c){sup 2}. The data are used for the evaluation of the Ellis-Jaffe and Bjorken sum rules. The neutron spin structure function g{sub 1}{sup n} (x, Q{sup 2}) is small and negative within the range of our measurement, yielding an integral {integral}{sub 0.03}{sup 0.6} g{sub 1}{sup n} (x)dx - 0.028 {+-} 0.006 (stat) {+-} 0.006 (syst). Assuming Regge behavior at low x, we extract {Gamma}{sub 1}{sup n} {integral}{sub 0}{sup 1} g{sub 1}{sup n} (x)dx = - 0.031 {+-} 0.006 (stat) {+-} 0.009 (syst). Combined with previous proton integral results from SLAC experiment E143, we find {Gamma}{sub 1}{sup p} - {Gamma}{sub 1}{sup n} = 0.160 {+-} 0.015 in agreement with the Bjorken sum rule prediction {Gamma}{sub 1}{sup p} - {Gamma}{sub 1}{sup p} 0.176 {+-} 0.008 at a Q{sup 2} value of 3 (GeV/c){sup 2} evaluated using {alpha}{sub s} 0.32 {+-} 0.05. (authors). 109 refs.

  5. The sup(40,44,48)Ca(3He, 3He) and (3He, 4He) reactions at 50 MeV

    International Nuclear Information System (INIS)

    Griffiths, R.J.; Duggan, F.; Clarke, N.M.

    1981-01-01

    Measurements have been made of the ( 3 He, 3 He) and ( 3 He, 4 He) reactions on the isotopes of calcium 40 Ca, 44 Ca and 48 Ca at an energy of 50.4 MeV. The results have been analysed with conventional optical potentials and DWBA. The adequacy of the former and inadequacy of the latter for reactions with composite particles is discussed. (author)

  6. Combined He3 cryostats and He3-He4 dilution refrigerators

    International Nuclear Information System (INIS)

    Kovac, L.; Balla, J.

    1974-07-01

    A modular set of equipment was designed, which consists of a 4 He Dewar vessel with a very low evaporation rate, having a pumped 4 He bath in which either a 3 He cryostat or a dilution refrigerator within removable inserts can be placed. Any of them can be simply and rapidly connected to the versatile Dewar, auxiliary 4 He-, vacuum; and 3 He- 4 He systems. Two such sets have already been completed and can be used at temperatures from 1.5K to 0.05K for thermodynamic and neutron diffraction measurements. The performance of all inserts was stable and reliable, differences between the cryostats and runs were small - nearly all within the accuracy of temperature determination. The construction of a lot of parts is identical, allowing rapid manufacture. Assembling and repairs are simple, all parts are easily accessible. (K.A.)

  7. High-momentum response of liquid He3

    International Nuclear Information System (INIS)

    Mazzanti, F.; Polls, A.; Boronat, J.; Casulleras, J.

    2004-01-01

    A final-state-effects formalism suitable to analyze the high-momentum response of Fermi liquids is presented and used to study the dynamic structure function of liquid He 3 . The theory, developed as a natural extension of the Gersch-Rodriguez formalism, incorporates the Fermi statistics explicitly through a new additive term which depends on the semidiagonal two-body density matrix. The use of a realistic momentum distribution, calculated using the diffusion Monte Carlo method, and the inclusion of this additive correction allows for good agreement with available deep-inelastic neutron scattering data

  8. Spin-exchange and spin-destruction rates for the 3He-Na system

    International Nuclear Information System (INIS)

    Borel, P.I.; Soegaard, L.V.; Svendsen, W.E.; Andersen, N.

    2003-01-01

    Optically pumped Na is used as a spin-exchange partner to polarize 3 He. Polarizations around 20% have routinely been achieved in sealed spherical glass cells containing 3 He, N 2 , and a few droplets of Na. An optical technique has been developed to determine the Na- 3 He spin-exchange rate coefficient. By monitoring the Na spin relaxation ''in the dark,'' the average Na-Na spin-destruction cross section at 330 degree sign C is estimated to be around 5x10 -19 cm 2 . This value is 2-5 (15-30) times smaller than the previously reported values for the K-K (Rb-Rb) spin-relaxation cross section. In the temperature range 310-355 degree sign C the spin-exchange rate coefficient is found to be (6.1±0.6)x10 -20 cm 3 /s with no detectable temperature dependence. This value is in good agreement with a previous theoretical estimate reported by Walker and it is only slightly lower than the corresponding Rb- 3 He spin-exchange rate coefficient. The total Na- 3 He spin-destruction rate coefficient is, within errors, found to be the same as the Na- 3 He spin-exchange rate coefficient, thereby indicating that the maximum possible photon efficiency may approach unity for the Na- 3 He system. A technique, in which a charge-coupled device camera is used to take images of faint unquenched fluorescence light, has been utilized to allow for an instantaneous determination of the sodium number densities during the rate coefficient measurements

  9. The effects of polarized light therapy in pressure ulcer healing

    Directory of Open Access Journals (Sweden)

    Đurović Aleksandar

    2008-01-01

    Full Text Available Background/Aim. Neglecting polarized light as an adjuvant therapy for pressure ulcers and methodology distinctions in the trials engaging polarized light are the reasons for many dilemmas and contradictions. The aim of this study was to establish the effects of polarized light therapy in pressure ulcer healing. Methods. This prospective randomized single-blind study involved 40 patients with stage I-III of pressure ulcer. The patients in the experimental group (E were subjected, besides polarized light therapy, to standard wound cleaning and dressing. Standard wound cleaning and dressing were the only treatment used in the control group (C. A polarized light source was a Bioptron lamp. Polarized light therapy was applied for six min daily, five times a week, four weeks. The Pressure Ulcer Scale for Healing (PUSH was used in the assessment of outcome. Statistic analysis included Mann Whitney Test, Fisher Exact Test, Wilcoxon Signed Rank test. Results. There were significant differences between the groups at the end of the treatment regarding the surface of pressure ulcer (E: 10.80±19.18; C: 22,97±25,47; p = 0.0005, rank of pressure ulcer (E: 5.90±2.48; C: 8.6±1.05; p = 0.0005 and total PUSH score (E: 7.35±3.17; C: 11.85±2.35; p = 0,0003. The patients in the experimental group had significantly better values of the parameters monitored than the patients in the control group. Conclusion. After a four-week polarized light therapy 20 patients with stage I-III ulcer had significant improvement in pressure ulcer healing, so it could be useful to apply polarized light in the treatment of pressure ulcers.

  10. Experimental study of the spin structure of the neutron (3He) with low Q2: a relationship between the Bjorken and Gerasimov-Drell-Hearn sum rules

    International Nuclear Information System (INIS)

    Deur, A.

    2000-10-01

    This thesis presents an experimental study of the neutron (and 3 He) spin structure with a particular emphasis in the resonance domain (experiment E94010 that took place in 1997 at Jefferson Lab (TJNAF or formerly CEBAF) in Virginia). A polarized 3 He target was built in order to achieve this study since polarized 3 He nuclei can be seen as polarized neutrons. This target allowed the measurement of the polarized absolute cross sections σ 1/2 (Q 2 , ν) and σ 3/2 (Q 2 , ν) from the inclusive reaction → 3 He( → e, e')X for incident beam energies ranging from 0.86 GeV to 5.07 GeV at a scattering angle of 15.5 deg. The Q 2 evolution of the generalized Gerasimov-Drell-Hearn (GDH) integral on 3 He and on neutron was measured from 0.1 GeV 2 to 1.0 GeV 2 in order to understand the transition between perturbative QCD and non-perturbative QCD. The integration domain in ν (the energy loss of the scattered electron) is from the pion threshold to about 2.5 GeV which covers both the resonance region and the Deep Inelastic Scattering. The high precision of our data constrains the models giving the Q 2 evolution of the generalized GDH integral. The polarized quasi-elastic scattering was also measured. The cross section σ TT (Q 2 , ν) on 3 He and the spin structure functions g 1 3 He (Q 2 , ν) and g 2 3 He (Q 2 , ν) are presented. These data are an indication that the higher-twists are small in our kinematics domain and that the Bloom-Gilman duality seems to hold for the polarized spin structure functions. (author)

  11. A rate-equation model for polarized laser-induced fluorescence to measure electric field in glow discharge He plasmas

    International Nuclear Information System (INIS)

    Takiyama, K.; Watanabe, M.; Oda, T.

    1998-01-01

    Possibility of applying polarized laser-induced fluorescence (LIF) spectroscopy for measuring the electric field in a plasma with a large collisional depolarization has been investigated. A rate equation model including the depolarization process was employed to analyze the time evolution of LIF polarization components. The polarized LIF pulse shapes observed in the sheath of a He glow discharge plasma were successfully reproduced, and the electric field distribution was obtained with high accuracy. (author)

  12. Nuclear reactivity control using laser induced polarization

    International Nuclear Information System (INIS)

    Bowman, C.D.

    1990-01-01

    This patent describes a control element for reactivity control of a fission source provides an atomic density of 3 He in a control volume which is effective to control criticality as the 3 He is spin-polarized. Spin-polarization of the 3 He affects the cross section of the control volume for fission neutrons and hence, the reactivity. An irradiation source is directed within the 3 He for spin-polarizing the 3 He. An alkali-metal vapor may be included with the 3 He where a laser spin-polarizes the alkali-metal atoms which in turn, spin-couple with 3 He to spin-polarize the 3 He atoms

  13. Measurement of the Spin Structure Function of the Neutron G1(N) from Deep Inelastic Scattering of Polarized Electrons from Polarized Neutrons in He-3

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, J

    2004-01-06

    Polarized electrons of energies 19.42, 22.67, and 25.5 GeV were scattered off a polarized {sup 3}He target at SLAC's End Station A to measure the spin asymmetry of the neutron. From this asymmetry, the spin dependent structure function g{sub 1}{sup n}(x) was determined over a range in x from 0.03 to 0.6 with an average Q{sup 2} of 2 (GeV/C){sup 2}. The value of the integral of g{sub 1}{sup n} over x is {integral}g{sub 1}{sup n}(x)dx = -0.036 {+-} 0.009. The results were interpreted in the frame work of the Quark Parton Model (QPM) and used to test the Ellis-Jaffe and Bjorken sum rules. The value of the integral is 2.6 standard deviations from the Ellis-Jaffe prediction while the Bjorken sum rule was found to be in agreement with this data and proton data from SMC and E-143.

  14. A high volume, batch mode {sup 129}Xe polarizer

    Energy Technology Data Exchange (ETDEWEB)

    Wojna-Pelczar, Anna, E-mail: anna.wojna.pelczar@mail.muni.cz [Central European Institute of Technology, Masaryk University, Brno (Czech Republic); Formerly: Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków (Poland); Pałasz, Tadeusz [Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków (Poland)

    2017-06-01

    Numerous designs of optical gas polarizers have been proposed, broadening possible applications of the hyperpolarized gases as contrast agents in magnetic resonance imaging. We present a home–made {sup 129}Xe polarizer based on the spin exchange optical pumping method. The polarizer operates under 1 bar of the gas mixture (at the maximum temperature of 160 °C) in a high volume optical cell (5025 cm{sup 3}). Approximately 100 cm{sup 3} of {sup 129}Xe polarized at 1.50±0.37% is produced in a single cycle of polarization. Operation under standard pressure imposes polarization transfer mainly via van der Waals molecules, resulting in the efficient spin exchange between rubidium and {sup 129}Xe atoms. The design, construction and operation of the polarizer are described in details.

  15. Polarization extinction ratio of the polarization crosstalk caused by point pressure force in the polarization-maintaining fiber

    Science.gov (United States)

    Mukhtubayev, Azamat B.; Aksarin, Stanislav M.; Strigalev, Vladimir E.

    2017-11-01

    A study of the orthogonal polarization modes crosstalk changes in the point of different mechanical actions (pressure force) in the polarization-maintaining fiber with straining elliptical cladding is presented. It was found that by increasing of the pressure force the polarization extinction ratio increases nonlinearly. Also revealed the dependence of the extinction coefficient and the angle between vector of the mechanical action and polarization axes of the test fiber, which leads to change the extinction coefficient variable from -57 dB to -25 dB under the pressure force of 0.7 N. Also it was found that the cross angle of the fiber axes doesn't influence on the extinction ratio value of the mechanical induced polarization crosstalk.

  16. Positive ion mobilities in normal liquid 3He at ultralow temperatures

    International Nuclear Information System (INIS)

    Alexander, P.W.

    1978-11-01

    The mobility has been measured of positive ions in liquid 3 he in the range 2.5 mK 3 sub(m)/sup(V) 5 sub(m)/sup(V). The effects of 500 p.p.m. 4 He in the 3 He were investigated. It was found that, at low temperatures, several stable ion species could be produced for 3 He pressures of 23 bar and above and, between 25 mK and 60 mK, time dependent conversion from one species of ion to another was observed at all pressures. The creation mechanism, mobility and stability of multiple positive ions were studied. Possible explanations of the phenomena are discussed. The measured drift field dependence of mobility is used to test the quasiparticle scattering model assumed for the liquid. (U.K.)

  17. Remeasurement of p/suby/ for the 2H(d, n)3He reaction and its bearing on the reported f-wave admixture of the lowest 2- state in 4He

    International Nuclear Information System (INIS)

    Tornow, W.; Skubic, S.E.; Byrd, R.C.; Lisowski, P.W.; Walter, R.L.

    1976-01-01

    The polarization of neutrons from the reaction 2 H(d, n) 3 He has been measured for a deuteron energy E/subd/ = 2.44 MeV at emission angles of 45degree and 55degree (lab). The polarization values are discussed in relation both to previously reported discrepant data and to measured differences between p/suby/ and A/suby/ in the reaction 3 H(p, n) 3 He

  18. Nuclear magnetism of liquid 3He: new determination of the Landau parameter F0a

    International Nuclear Information System (INIS)

    Goudon, V.

    2006-10-01

    He 3 is a liquid Fermi model, isotropic, with an attainable Fermi temperature and the interaction between atoms can be controlled by changing the pressure of the liquid. In this document, we present accurate NMR measurements of the nuclear magnetic susceptibility of liquid He 3 as a function of temperature and pressure. The emphasis has been placed on reliable thermometry and on He 3 pressure measurements directly in the cell to increase the measuring range until solidification, and an accurate characterization of the NMR spectrometer. Our measurements give an effective Fermi temperature 5% lower than former results. The Landau parameter F 0 a depends on the effective mass, which is determined by specific heat measurements, and consequently on the temperature scale. The re-analysis of the specific heat measurements with the PLTS-2000 temperature scale yields an effective mass increase of 4.5%. In this document, F 0 a is determined for 2 temperature scales (PLTS-2000 and Greywall). Contrarily to former measurements, the F 0 a density dependence does not show any saturation at high pressures. (author)

  19. 4He-impurity effects on normal liquid 3He at low temperatures I - preliminary ideas and calculations

    International Nuclear Information System (INIS)

    Ghassib, H.B.; Chatterjee, S.

    1982-02-01

    The effects of 4 He impurities on the low-temperature properties of normal liquid 3 He are explored. It is argued that these effects should manifest themselves in, among other properties, the liquid structure factor at very low temperatures and momentum transfers, the acoustic impedance near the transition region from the zero- to the first-sound regime, the propagation of sound, the phase diagram, and the magnetic properties - including the magnetokinetic coefficients of the spin-polarized system. Several experiments are suggested to detect these macroscopic manifestations. (author)

  20. Application of the cubic-plus-association equation of state to mixtures with polar chemicals and high pressures

    DEFF Research Database (Denmark)

    Folas, Georgios; Kontogeorgis, Georgios; Michelsen, Michael Locht

    2006-01-01

    was given to low pressures and liquid-liquid equilibria. In this work, CPA is applied to two classes of mixtures containing polar chemicals for which high-pressure data are available: acetone-containing systems and dimethyl ether mixtures. They are of both scientific and industrial importance. Moreover, CPA......The cubic-plus-association (CPA) equation of state has been previously applied to vapor-liquid, liquid-liquid, and solid-liquid equilibria of mixtures containing associating compounds (water, alcohols, glycols, acids, amines). Although some high-pressure applications have been presented, emphasis...... to conventional models such as MHV2. Very good results are also obtained for multicomponent vapor-liquid-liquid equilibria for mixtures containing gases, water, and dimethyl ether. Finally, it is shown that high-pressure SLE can be predicted based on interaction parameters obtained from low-pressure SLE data....

  1. Direct harvesting of Helium-3 (3He) from heavy water nuclear reactors

    International Nuclear Information System (INIS)

    Bentoumi, G.; Didsbury, R.; Jonkmans, G.; Rodrigo, L.; Sur, B.

    2013-01-01

    The thermal neutron activation of deuterium inside a heavy-water-moderated or -cooled nuclear reactor produces a build-up of tritium in the heavy water. The in situ decay of tritium can, for certain reactor types and operating conditions, produce potentially useable amounts of 3 He, which can be directly extracted via the heavy-water cover gas without first separating, collecting and storing tritium outside the reactor. It is estimated that the amount of 3 He available for recovery from the moderator cover gas of a 700 MWe class Pressurized Heavy Water Reactor (PHWR) ranges from 0.1 to 0.7 m 3 (STP) per annum, varying with the tritium activity buildup in the moderator. The harvesting of 3 He would generate approximately 12.7 m 3 (STP) of 3 He, worth more than $30M at current market rates, over a typical 25-year operating cycle of the PHWR. This paper discusses the production of 3 He in the moderator of a PHWR and its extraction from the 4 He moderator cover gas system using conventional methods. (author)

  2. Experimental study of the spin structure of the neutron ({sup 3}He) with low Q{sup 2}: a relationship between the Bjorken and Gerasimov-Drell-Hearn sum rules; Etude experimentale de la structure en spin du neutron ({sup 3}He) a bas Q{sup 2}: une connexion entre les regles de somme de Bjorken et Gerasimov-Drell-Hearn

    Energy Technology Data Exchange (ETDEWEB)

    Deur, A

    2000-10-01

    This thesis presents an experimental study of the neutron (and {sup 3}He) spin structure with a particular emphasis in the resonance domain (experiment E94010 that took place in 1997 at Jefferson Lab (TJNAF or formerly CEBAF) in Virginia). A polarized {sup 3}He target was built in order to achieve this study since polarized {sup 3}He nuclei can be seen as polarized neutrons. This target allowed the measurement of the polarized absolute cross sections {sigma}{sub 1/2}(Q{sup 2}, {nu}) and {sigma}{sub 3/2}(Q{sup 2}, {nu}) from the inclusive reaction {sup {sup {yields}}{sup 3}He}({sup {yields}}e, e')X for incident beam energies ranging from 0.86 GeV to 5.07 GeV at a scattering angle of 15.5 deg. The Q{sup 2} evolution of the generalized Gerasimov-Drell-Hearn (GDH) integral on {sup 3}He and on neutron was measured from 0.1 GeV{sup 2} to 1.0 GeV{sup 2} in order to understand the transition between perturbative QCD and non-perturbative QCD. The integration domain in {nu} (the energy loss of the scattered electron) is from the pion threshold to about 2.5 GeV which covers both the resonance region and the Deep Inelastic Scattering. The high precision of our data constrains the models giving the Q{sup 2} evolution of the generalized GDH integral. The polarized quasi-elastic scattering was also measured. The cross section {sigma}{sup TT}(Q{sup 2}, {nu}) on {sup 3}He and the spin structure functions g{sub 1}{sup {sup 3}He}(Q{sup 2}, {nu}) and g{sub 2}{sup {sup 3}He}(Q{sup 2}, {nu}) are presented. These data are an indication that the higher-twists are small in our kinematics domain and that the Bloom-Gilman duality seems to hold for the polarized spin structure functions. (author)

  3. Experimental study of the spin structure of the neutron ({sup 3}He) with low Q{sup 2}: a relationship between the Bjorken and Gerasimov-Drell-Hearn sum rules; Etude experimentale de la structure en spin du neutron ({sup 3}He) a bas Q{sup 2}: une connexion entre les regles de somme de Bjorken et Gerasimov-Drell-Hearn

    Energy Technology Data Exchange (ETDEWEB)

    Deur, A

    2000-10-01

    This thesis presents an experimental study of the neutron (and {sup 3}He) spin structure with a particular emphasis in the resonance domain (experiment E94010 that took place in 1997 at Jefferson Lab (TJNAF or formerly CEBAF) in Virginia). A polarized {sup 3}He target was built in order to achieve this study since polarized {sup 3}He nuclei can be seen as polarized neutrons. This target allowed the measurement of the polarized absolute cross sections {sigma}{sub 1/2}(Q{sup 2}, {nu}) and {sigma}{sub 3/2}(Q{sup 2}, {nu}) from the inclusive reaction {sup {sup {yields}}{sup 3}He}({sup {yields}}e, e')X for incident beam energies ranging from 0.86 GeV to 5.07 GeV at a scattering angle of 15.5 deg. The Q{sup 2} evolution of the generalized Gerasimov-Drell-Hearn (GDH) integral on {sup 3}He and on neutron was measured from 0.1 GeV{sup 2} to 1.0 GeV{sup 2} in order to understand the transition between perturbative QCD and non-perturbative QCD. The integration domain in {nu} (the energy loss of the scattered electron) is from the pion threshold to about 2.5 GeV which covers both the resonance region and the Deep Inelastic Scattering. The high precision of our data constrains the models giving the Q{sup 2} evolution of the generalized GDH integral. The polarized quasi-elastic scattering was also measured. The cross section {sigma}{sup TT}(Q{sup 2}, {nu}) on {sup 3}He and the spin structure functions g{sub 1}{sup {sup 3}He}(Q{sup 2}, {nu}) and g{sub 2}{sup {sup 3}He}(Q{sup 2}, {nu}) are presented. These data are an indication that the higher-twists are small in our kinematics domain and that the Bloom-Gilman duality seems to hold for the polarized spin structure functions. (author)

  4. Few-body experiments with polarized beams and polarized targets

    International Nuclear Information System (INIS)

    Simmons, J.E.

    1983-01-01

    A survey is presented concerning recent polarization experiments in the elastic p-d, p- 3 He, and p- 4 He systems. Mention is made of selected neutron experiments. The nominal energy range is 10 to 1000 MeV. Recent results and interpretations of the p-d system near 10 MeV are discussed. New experiments on the energy dependence of back angle p-d tensor polarization are discussed with respect to resolution of discrepancies and difficulty of theoretical interpretation. Progress is noted concerning multiple scattering interpretation of forward p-d deuteron polarization. Some new results are presented concerning the p- 3 He system and higher energy p- 4 He polarization experiments. 52 references

  5. Study of elastic scattering of polarized proton with 6He by folding model

    International Nuclear Information System (INIS)

    Iseri, Y.; Tanifuji, M.; Ishikawa, S.; Hiyama, E.; Yamamoto, Y.

    2005-01-01

    Experimental data of the elastic scattering of 6 He with polarized proton target has been analyzed using a simple folding model. As we regard 6 He as three bodies consisting of 4 He+n+n, the potential between the proton and 6 He is obtained by folding the two potentials, one between a proton and 4 He and another between a proton and a neutron, with the density distribution of 6 He. Calculated results of both the differential cross section and the vector analyzing power reproduce the experimental data satisfactorily. It is shown that the vector analyzing power of the p- 6 He scattering is mainly due to the spin orbit interaction between the proton and 4 He. (S. Funahashi)

  6. Hard breakup of two nucleons from the 3He nucleus

    International Nuclear Information System (INIS)

    Sargsian, Misak M.; Granados, Carlos

    2009-01-01

    We investigate a large angle photodisintegration of two nucleons from the 3 He nucleus within the framework of the hard rescattering model (HRM). In the HRM a quark of one nucleon knocked out by an incoming photon rescatters with a quark of the other nucleon leading to the production of two nucleons with large relative momentum. Assuming the dominance of the quark-interchange mechanism in a hard nucleon-nucleon scattering, the HRM allows the expression of the amplitude of a two-nucleon breakup reaction through the convolution of photon-quark scattering, NN hard scattering amplitude, and nuclear spectral function, which can be calculated using a nonrelativistic 3 He wave function. The photon-quark scattering amplitude can be explicitly calculated in the high energy regime, whereas for NN scattering one uses the fit of the available experimental data. The HRM predicts several specific features for the hard breakup reaction. First, the cross section will approximately scale as s -11 . Second, the s 11 weighted cross section will have the shape of energy dependence similar to that of s 10 weighted NN elastic scattering cross section. Also one predicts an enhancement of the pp breakup relative to the pn breakup cross section as compared to the results from low energy kinematics. Another result is the prediction of different spectator momentum dependencies of pp and pn breakup cross sections. This is due to the fact that the same-helicity pp-component is strongly suppressed in the ground state wave function of 3 He. Because of this suppression the HRM predicts significantly different asymmetries for the cross section of polarization transfer NN breakup reactions for circularly polarized photons. For the pp breakup this asymmetry is predicted to be zero while for the pn it is close to (2/3).

  7. Inelastic electron scattering from 3He and 4He in the threshold region at high momentum transfer

    International Nuclear Information System (INIS)

    Rock, S.; Arnold, R.G.; Chertok, B.T.; Szalata, Z.M.; Day, D.; McCarthy, J.S.; Martin, F.; Mecking, B.A.; Sick, I.; Tamas, G.

    1981-01-01

    The cross section for inclusive inelastic electron scattering from the helium isotopes has been measured at momentum transfers squared of 0.8 less than or equal to Q 2 less than or equal to 5.0 (GeV/c) 2 for 3 He and 0.8 less than or equal to Q 2 less than or equal to 2.4 (GeV/c) 2 for 4 He. The data were taken at 10 0 and cover the range 1.0 2 /2M/sub He/ν, which includes the elastic peak, nuclear breakup threshold, the high momentum tail of the quasi elastic scattering, and pion production. The structure function, νW 2 , derived from the data is approaching a scaling limit at high Q 2 . It can be factored into a product of functions of Q 2 and of x as predicted by some models

  8. Examination of X-ray spectra from the antiprotonic helium isotopes 3He and 4He

    International Nuclear Information System (INIS)

    Schneider, M.

    1987-05-01

    Using the high intensity antiprotonic LEAR beam at CERN (Geneva), several measurements were done to investigate the X-ray spectra of the antiprotonic Helium isotopes 3 He and 4 He. For the first time antiprotons were stopped in gases at low pressures (600, 375, 72 and 36 mbar), which permitted observations on nearly isolated atoms. A newly developed method for stopping the antiprotons in gases by means of a focusing cyclotron field surrounding the target gas was used. The field was supplied by a superconducting magnet ('cyclotron trap'). The antiprotons were tangentially injected into the cyclotron field, where they slowed down by ionising the target gas. The inhomogeneous magnetic field guided the antiprotons in spiral orbits to the magnetic center. Thus, even at low pressures a very small stopping volume could be achieved. To detect the X-rays different Si(Li)- and Ge-semiconductor detectors were used, some of which were furnished with 'guard-rings'. They were used to investigate the effects of the strong interaction between the antiproton and the nucleus in the (3d → 2p) transition in both isotopes. The analyzis of this transition permitted directly the determination of the shift and width of the 2p-level. The width of the 3d-level could be determined only indirectly using an intensity balance. The utilization of gases with different pressures permitted investigations of the pressure dependence of the antiprotonic deexcitation process. The results for the widths and shifts were compared with earlier measurements and theoretical predictions. The theory agrees only partly with the measurements. The evaluation of a complex scattering length using an optical model contradicts some of the results of calculations. (orig.) [de

  9. Structure of vortices in superfluid 3He A-like phase in uniaxially stretched aerogel

    International Nuclear Information System (INIS)

    Aoyama, Kazushi; Ikeda, Ryusuke

    2009-01-01

    Possible vortex-core transitions in A-like phase of superfluid 3 He in uniaxially stretched aerogel are investigated. Since the global anisotropy in this system induces the polar pairing state in a narrow range close to the superfluid transition in addition to the A-like and B-like phases, the polar state may occur in the core of a vortex in the A-like phase identified with the ABM pairing state, like in the case of the bulk B phase where a core including the ABM state is realized at higher pressures. We examine the core structure of a single vortex under the boundary condition compatible with the Mermin-Ho vortex in the presence of the dipole interaction. Following Salomaa and Volovik's approach, we numerically solve the Ginzburg-Landau equation for an axially symmetric vortex and, by examining its stability against nonaxisymmetric perturbations, discuss possible vortex core states. It is found that a first order transition on core states may occur on warming from an axisymmetric vortex with a nonunitary core to a singular vortex with the polar core.

  10. Structure of vortices in superfluid 3He A-like phase in uniaxially stretched aerogel

    Science.gov (United States)

    Aoyama, Kazushi; Ikeda, Ryusuke

    2009-02-01

    Possible vortex-core transitions in A-like phase of superfluid 3He in uniaxially stretched aerogel are investigated. Since the global anisotropy in this system induces the polar pairing state in a narrow range close to the superfluid transition in addition to the A-like and B-like phases, the polar state may occur in the core of a vortex in the A-like phase identified with the ABM pairing state, like in the case of the bulk B phase where a core including the ABM state is realized at higher pressures. We examine the core structure of a single vortex under the boundary condition compatible with the Mermin-Ho vortex in the presence of the dipole interaction. Following Salomaa and Volovik's approach, we numerically solve the Ginzburg-Landau equation for an axially symmetric vortex and, by examining its stability against nonaxisymmetric perturbations, discuss possible vortex core states. It is found that a first order transition on core states may occur on warming from an axisymmetric vortex with a nonunitary core to a singular vortex with the polar core.

  11. Early episodes of high-pressure core formation preserved in plume mantle

    Science.gov (United States)

    Jackson, Colin R. M.; Bennett, Neil R.; Du, Zhixue; Cottrell, Elizabeth; Fei, Yingwei

    2018-01-01

    The decay of short-lived iodine (I) and plutonium (Pu) results in xenon (Xe) isotopic anomalies in the mantle that record Earth’s earliest stages of formation. Xe isotopic anomalies have been linked to degassing during accretion, but degassing alone cannot account for the co-occurrence of Xe and tungsten (W) isotopic heterogeneity in plume-derived basalts and their long-term preservation in the mantle. Here we describe measurements of I partitioning between liquid Fe alloys and liquid silicates at high pressure and temperature and propose that Xe isotopic anomalies found in modern plume rocks (that is, rocks with elevated 3He/4He ratios) result from I/Pu fractionations during early, high-pressure episodes of core formation. Our measurements demonstrate that I becomes progressively more siderophile as pressure increases, so that portions of mantle that experienced high-pressure core formation will have large I/Pu depletions not related to volatility. These portions of mantle could be the source of Xe and W anomalies observed in modern plume-derived basalts. Portions of mantle involved in early high-pressure core formation would also be rich in FeO, and hence denser than ambient mantle. This would aid the long-term preservation of these mantle portions, and potentially points to their modern manifestation within seismically slow, deep mantle reservoirs with high 3He/4He ratios.

  12. Binary and ternary recombination of D3+ ions with electrons in He-D2 plasma

    International Nuclear Information System (INIS)

    Glosik, J.; Korolov, I.; Plasil, R.; Kotrik, T.; Dohnal, P.; Novotny, O.; Varju, J.; Roucka, S.; Greene, Chris H.; Kokoouline, V.

    2009-01-01

    An experimental study is reported about the recombination of D 3 + ions with electrons in a low-temperature plasma (200-300 K) consisting of He with a small admixture of D 2 . At several temperatures, the pressure dependence of the apparent binary recombination rate coefficient (α eff ) was measured over a broad range of helium pressures (200-2000 Pa). The binary and ternary recombination rate coefficients were obtained from measured pressure dependences of α eff . The binary recombination rate coefficient obtained α bin (300 K)=(2.7±0.9)x10 -8 cm 3 s -1 is in agreement with recent theory. The ternary recombination rate coefficient obtained is K He (300 K)=(1.8±0.6)x10 -25 cm 6 s -1 . In analogy with the recently described process of helium-assisted ternary recombination of H 3 + ions, it is suggested that the ternary helium-assisted recombination of D 3 + ions proceeds through the formation of a neutral long-lived highly excited Rydberg molecule D 3 followed by a collision with a He atom.

  13. Equality of analyzing power and polarization in the reaction 3H(p,n)3He

    International Nuclear Information System (INIS)

    Donoghue, T.R.; Doyle, S.M.A.; Clark, H.W.; Dries, L.J.; Regner, J.L.; Tornow, W.; Byrd, R.C.; Lisowski, P.W.; Walter, R.L.

    1976-01-01

    The quantities A/sub y/ and P/sub y/ were remeasured for E/sub p/ 3 H(p,n) 3 He. Although our A/sub y/ data confirm previous data, our P/sub y/ values are appreciably larger than earlier results and in fact agree well with those for A/sub y/. Elimination of the previously reported A/sub y/-P/sub y/ difference has important consequences. Charge-symmetry-breaking effects must be small or nonexistent in this reaction; and the previously required f-wave admixture to the lowest J/sup pi/=2 - state of 4 He is no longer necessary

  14. Hyperbaric pressure effects measured by growth of a transplantable tumor in the C3H/HeN mouse.

    Science.gov (United States)

    Herndon, B L; Lally, J J

    1984-09-01

    Both hypobaric exposure at 0.5 atmospheres absolute (ATA) and hyperbaric pressure exposure at 3.5-8 ATA slowed transplantable tumor growth. These experiments detailed the hyperbaric pressure exposure. C3H/HeN-MTV+ mice, bearing the 16/C transplantable murine mammary adenocarcinoma and exposed to 18 days' treatment by a hyperbaric chamber at 3.5-8 ATA, had tumor weights that averaged 50-75% less than the tumor weights in mice caged at ambient ("sea level") pressure. A series of experiments was run to investigate this response to hyperbaric pressure exposure. After mice underwent continuous exposure to 3.5-8 ATA normoxic (normal oxygen) hyperbaric pressure with use of either argon or nitrogen inert gas, which began 3 days after tumor inoculation, tumors were removed at about 3 weeks' growth from these pressure-exposed mice and measured for growth by weighing. Final tumor weight in pressure-exposed experimental mice was significantly less than tumor weight in paired groups of tumor-bearing controls that received no hyperbaric pressure. Tumor weight was inversely related to pressure "dose," although the small pressure range produced an effect at all pressures used. The number of compression-decompression cycles to which the animals were subjected, however, was related positively to tumor weight at necropsy. Continued tumor growth in mice subjected to frequent pressure change (in conjunction with pressure exposure that otherwise limited tumor size) was unexplained by these experiments. The greatest difference between tumor weights in controls and pressure-exposed animals was seen with 2 weeks' continuous pressure exposure. A limited profile of blood tests was performed, and these reflected only minor, expected change in the pressure-exposed experimental animals. The data at hand did not suggest a mechanism by which chronic normoxic hyperbaric pressure limited tumor size.

  15. Boron-coated straws as a replacement for 3He-based neutron detectors

    International Nuclear Information System (INIS)

    Lacy, Jeffrey L.; Athanasiades, Athanasios; Sun, Liang; Martin, Christopher S.; Lyons, Tom D.; Foss, Michael A.; Haygood, Hal B.

    2011-01-01

    US and international government efforts to equip major seaports with large area neutron detectors, aimed to intercept the smuggling of nuclear materials, have precipitated a critical shortage of 3 He gas. It is estimated that the annual demand of 3 He for US security applications alone is more than the worldwide supply. This is strongly limiting the prospects of neutron science, safeguards, and other applications that rely heavily on 3 He-based detectors. Clearly, alternate neutron detection technologies that can support large sensitive areas, and have low gamma sensitivity and low cost must be developed. We propose a low-cost technology based on long copper tubes (straws), coated on the inside with a thin layer of 10 B-enriched boron carbide ( 10 B 4 C). In addition to the high abundance of boron on Earth and low cost of 10 B enrichment, the boron-coated straw (BCS) detector offers distinct advantages over conventional 3 He-based detectors, and alternate technologies such as 10 BF 3 tubes and 10 B-coated rigid tubes. These include better distribution inside moderator assemblies, many-times faster electronic signals, no pressurization, improved gamma-ray rejection, no toxic or flammable gases, and ease of serviceability. We present the performance of BCS detectors dispersed in a solid plastic moderator to address the need for portal monitoring. The design adopts the outer dimensions of currently deployed 3 He-based monitors, but takes advantage of the small BCS diameter to achieve a more uniform distribution of neutron converter throughout the moderating material. We show that approximately 63 BCS detectors, each 205 cm long, distributed inside the moderator, can match or exceed the detection efficiency of typical monitors fitted with a 5 cm diameter 3 He tube, 187 cm long, pressurized to 3 atm.

  16. Boron-coated straws as a replacement for 3He-based neutron detectors

    Science.gov (United States)

    Lacy, Jeffrey L.; Athanasiades, Athanasios; Sun, Liang; Martin, Christopher S.; Lyons, Tom D.; Foss, Michael A.; Haygood, Hal B.

    2011-10-01

    US and international government efforts to equip major seaports with large area neutron detectors, aimed to intercept the smuggling of nuclear materials, have precipitated a critical shortage of 3He gas. It is estimated that the annual demand of 3He for US security applications alone is more than the worldwide supply. This is strongly limiting the prospects of neutron science, safeguards, and other applications that rely heavily on 3He-based detectors. Clearly, alternate neutron detection technologies that can support large sensitive areas, and have low gamma sensitivity and low cost must be developed. We propose a low-cost technology based on long copper tubes (straws), coated on the inside with a thin layer of 10B-enriched boron carbide ( 10B 4C). In addition to the high abundance of boron on Earth and low cost of 10B enrichment, the boron-coated straw (BCS) detector offers distinct advantages over conventional 3He-based detectors, and alternate technologies such as 10BF 3 tubes and 10B-coated rigid tubes. These include better distribution inside moderator assemblies, many-times faster electronic signals, no pressurization, improved gamma-ray rejection, no toxic or flammable gases, and ease of serviceability. We present the performance of BCS detectors dispersed in a solid plastic moderator to address the need for portal monitoring. The design adopts the outer dimensions of currently deployed 3He-based monitors, but takes advantage of the small BCS diameter to achieve a more uniform distribution of neutron converter throughout the moderating material. We show that approximately 63 BCS detectors, each 205 cm long, distributed inside the moderator, can match or exceed the detection efficiency of typical monitors fitted with a 5 cm diameter 3He tube, 187 cm long, pressurized to 3 atm.

  17. Measurement of alveolar oxygen partial pressure in the rat lung using Carr-Purcell-Meiboom-Gill spin-spin relaxation times of hyperpolarized 3He and 129Xe at 74 mT.

    Science.gov (United States)

    Kraayvanger, Ryan J; Bidinosti, Christopher P; Dominguez-Viqueira, William; Parra-Robles, Juan; Fox, Matthew; Lam, Wilfred W; Santyr, Giles E

    2010-11-01

    Regional measurement of alveolar oxygen partial pressure can be obtained from the relaxation rates of hyperpolarized noble gases, (3) He and (129) Xe, in the lungs. Recently, it has been demonstrated that measurements of alveolar oxygen partial pressure can be obtained using the spin-spin relaxation rate (R(2) ) of (3) He at low magnetic field strengths (oxygen partial pressure measurements based on Carr-Purcell-Meiboom-Gill R(2) values of hyperpolarized (3) He and (129) Xe in vitro and in vivo in the rat lung at low magnetic field strength (74 mT) are presented. In vitro spin-spin relaxivity constants for (3) He and (129) Xe were determined to be (5.2 ± 0.6) × 10(-6) Pa(-1) sec(-1) and (7.3 ± 0.4) × 10(-6) Pa(-1) s(-1) compared with spin-lattice relaxivity constants of (4.0 ± 0.4) × 10(-6) Pa(-1) s(-1) and (4.3 ± 1.3) × 10(-6) Pa(-1) s(-1), respectively. In vivo experimental measurements of alveolar oxygen partial pressure using (3) He in whole rat lung show good agreement (r(2) = 0.973) with predictions based on lung volumes and ventilation parameters. For (129) Xe, multicomponent relaxation was observed with one component exhibiting an increase in R(2) with decreasing alveolar oxygen partial pressure. Copyright © 2010 Wiley-Liss, Inc.

  18. Spin-polarized fuel in ICF pellets

    International Nuclear Information System (INIS)

    Wakuta, Yoshihisa; Emoto, Nobuya; Nakao, Yasuyuki; Honda, Takuro; Honda, Yoshinori; Nakashima, Hideki.

    1990-01-01

    The use of parallel spin-polarized DT or D 3 He fuel increases the fusion cross-section by 50%. By implosion-burn simulation for inertially confined fusion (ICF) pellets of the spin-polarized fuels, we found that the input energy requirement could be reduced by nearly a fact of two. These pellets taken up here include large-high-aspect-ratio DT target proposed in ILE Osaka University and DT ignitor/D 3 He fuel pellet proposed by our group. We also found that the polarized state could survive during the implosion-burn phase. (author)

  19. Calibration of cosmogenic 3He and 10Be production rates in the High Tropics

    Science.gov (United States)

    Blard, Pierre-Henri; Martin, Léo; Lavé, Jérôme; Charreau, Julien; Condom, Thomas; Lupker, Maarten; Braucher, Régis; Bourlès, Didier

    2014-05-01

    It is critical to refine both the accuracy and the precision of the in situ cosmogenic dating tool, especially for establishing reliable glacial chronologies that can be compared to other paleoclimatic records. Recent cross-calibrations of cosmogenic 3He in pyroxene and 10Be in quartz [1, 2] showed that, both at low (1300 m) and high elevation (4850 m), the 3He/10Be production ratio was probably ~40% higher than the value of ~23 initially defined in the 90's. This recent update is consistent with the last independent determinations of the sea level high latitude production rates of 10Be and 3He, that are about 4 and 125 at.g-1.yr-1, respectively [e.g. 3, 4]. However, major questions remain about these production rates at high elevation, notably because existing calibration sites for both 3He and 10Be are scarce above 2000 m. It is thus crucial to produce new high precision calibration data at high elevation. Here we report cosmogenic 10Be data from boulders sampled on a glacial fan located at 3800 m in the Central Altiplano (Bolivia), whose age is independently constrained by stratigraphic correlations and radiocarbon dating at ca. 16 ka. These data can be used to calibrate the production rate of 10Be at high elevation, in the Tropics. After scaling to sea level and high latitude, these data yield a sea level high latitude P10 ranging from 3.8 to 4.2 at.g-1.yr-1, depending on the used scaling scheme. These new calibration data are in good agreement with recent absolute and cross-calibration of 3He in pyroxenes and 10Be in quartz, from dacitic moraines located at 4850 m in the Southern Altiplano (22° S, Tropical Andes) [2,5]. The so-obtained 3He/10Be production ratio of 33.3±0.9 (1σ) combined with an absolute 3He production rate locally calibrated in the Central Altiplano, at 3800 m, indeed yielded a sea level high latitude P10 ranging from 3.7±0.2 to 4.1±0.2 at.g-1.yr-1, depending on the scaling scheme [2,5]. These values are also consistent with the 10Be

  20. Two-body photodisintegration of 3He between 7 and 16 MeV

    International Nuclear Information System (INIS)

    Tornow, W.; Karwowski, H.J.; Kelley, J.H.; Raut, R.; Rusev, G.; Stave, S.C.; Tonchev, A.P.; Deltuva, A.; Fonseca, A.C.; Marcucci, L.E.; Viviani, M.; Kievsky, A.; Golak, J.; Skibinski, R.; Witala, H.; Schiavilla, R.

    2011-01-01

    A comprehensive data set is reported for the two-body photodisintegration cross section of 3 He using mono-energetic photon beams at eleven energies between 7.0 and 16.0 MeV. A 3 He+Xe high-pressure gas scintillator served as target and detector. Although our data are in much better agreement with our state-of-the-art theoretical calculations than the majority of the previous data, these calculations underpredict the new data by about 10%. This disagreement suggests an incomplete understanding of the dynamics of the three-nucleon system and its response to electromagnetic probes.

  1. Annihilation of antiprotons at rest in 3He and 4He

    International Nuclear Information System (INIS)

    Balestra, F.; Bossolasco, S.; Bussa, M.P.; Busso, L.; Fava, L.; Ferrero, L.; Panzieri, D.; Piragino, G.; Tosello, F.; Bendiscioli, G.; Rotondi, A.; Salvini, P.; Zenoni, A.; Batusov, Yu.A.; Bunyatov, S.A.; Falomkin, I.V.; Nichitiu, F.; Pontecorvo, G.B.; Sapozhnikov, M.G.; Tretyak, V.I.; Guaraldo, C.; Maggiora, A.; Haatuft, A.; Halsteinslid, A.; Myklebost, K.; Olsen, J.M.; Breivik, F.O.; Jacobsen, T.; Soerensen, S.O.

    1987-01-01

    At LEAR of CERN the annihilation of antiprotons, stopping in 3 He and 4 He filling a self-shunted streamer chamber in a magnetic field, has been studied. The charged-particle multiplicities have been measured and the relative probabilities of π - production in anti p 3 He and anti p 4 He annihilation events have been obtained. The ratio between the anti p annihilation probability on the neutron and the proton for 3 He and 4 He has been deduced to be about half the value obtained for 2 H in bubble chamber experiments. The analysis of the results shows that this difference cannot be due only to the pion final-state interaction or to the shadow effect of the nucleons of the nuclei. The probability of anti p annihilation at rest on a proton bound in the nucleus results to be twice as high as that on a bound neutron, showing the dominance of annihilation in the I=0 isospin states. (orig.)

  2. The relation between temperature and concentration gradients in superfluid sup 3 He- sup 4 He solutions

    CERN Document Server

    Zadorozhko, A A; Rudavskij, E Y; Chagovets, V K; Sheshin, G A

    2003-01-01

    The temperature and concentration gradients nabla T and nabla x in a superfluid sup 3 He- sup 4 He mixture with an initial concentration 9,8 % of sup 3 He are measured in a temperature range 70-500 mK. The gradients are produced by a steady thermal flow with heating from below. It is shown that the value of nabla x/nabla T observed in the experiment is in good agreement with the theoretical model derived from the temperature and concentration dependences of osmotic pressure. The experimental data permitted us to obtain a thermal diffusion ratio of the solution responsible for the thermal diffusion coefficient.

  3. Attractive well of He--He from 3He--4He differential elastic scattering measurements

    International Nuclear Information System (INIS)

    Burgmans, A.L.J.; Farrar, J.M.; Lee, Y.T.

    1976-01-01

    The elastic differential cross section for 3 He-- 4 He was measured at a relative collision energy of 0.799x10 -14 erg, approximately five times the well depth. The data are fitted to a multiparameter potential form with epsilon/k=10.57 degreeK and r/subm/=2.97 A. Comparisons with recent experimental and theoretical helium potentials are made. No evidence for a significant isotope effect in the 3 He-- 4 He and 4 He-- 4 He interactomic potentials is found in this work

  4. Superfluidity of a dilute 3He-4He solution

    International Nuclear Information System (INIS)

    Soda, Toshio

    1993-01-01

    The interaction between two 3 He atoms is calculated by taking into account the backflow effect of 3 He by the 4 He in the 3 He- 4 He mixture. The effect contributes solely to the P wave part of the interaction. The repulsive S wave part of the contact interaction contributes to the exchange interaction between the 3 He atoms, while the direct one phonon exchange interaction contributes both to the S and P wave attractive interactions. The overall contribution to the attractive interaction is dominated by the P wave part and the superfluidity in the P wave is more predominant than in the S wave for the 5 % dilute 3 He- 4 He solution, and vice versa for the 1.3 % solution. (author)

  5. Anomalous He-gas high-pressure studies on superconducting LaO1-xFxFeAs

    International Nuclear Information System (INIS)

    Bi, W; Banks, H B; Schilling, J S; Takahashi, H; Okada, H; Kamihara, Y; Hirano, M; Hosono, H

    2010-01-01

    Ac susceptibility measurements have been carried out on superconducting LaO 1-x F x FeAs for x=0.07 and 0.14 under He-gas pressures to ∼0.8 GPa. Not only do the measured values of dT c /dP differ substantially from those obtained in previous studies using other pressure media, but also the T c (P) dependences observed depend on the detailed pressure/temperature history of the sample. A sizeable sensitivity of T c (P) to shear stresses provides a possible explanation.

  6. Dissipation of flow in superfluid 3He-A

    International Nuclear Information System (INIS)

    Paalanen, M.A.; Osheroff, D.D.

    1980-01-01

    The first direct measurements of the dissipation due to flow are performed and the effects of that flow on the NMR properties of 3 He-A are studied. A temperature-independent critical velocity v/sub c/=0.52 mm/s is observed, above which a pressure difference proportional to v/sub s/-v/sub c/ developes across our flow orifice. simultaneously, the NMR frequency in 3 He-A is lowered by an amount also proportional to v/sub s/-v/sub c/, in contrast to current theoretical predictions

  7. Spin effects in the screening and Auger neutralization of He+ ions in a spin-polarized electron gas

    International Nuclear Information System (INIS)

    Alducin, M.; Diez Muino, R.; Juaristi, J.I.

    2005-01-01

    The screening of a He + ion embedded in a free electron gas is studied for different spin-polarizations of the medium. Density functional theory and the local spin density approximation are used to calculate the induced electronic density for each spin orientation, i.e. parallel or antiparallel to the spin of the electron bound to the ion. Since both the He + ion and the electron gas are spin-polarized, we analyze in detail the spin state of the screening cloud for the two different possibilities: the spin of the bound electron can be parallel to either the majority spin or the minority spin in the medium. Finally, the spin-dependent Kohn-Sham orbitals are used to calculate the Auger neutralization rate of the He + ion. The polarization of the Auger excited electron is influenced by the spin-polarization of the medium. The results are discussed in terms of the spin-dependent screening and the indistinguishability of electrons with the same spin state

  8. The cross section of 3He(3He,2p)4He measured at solar energies

    International Nuclear Information System (INIS)

    Junker, M.; Arpesella, C.; Bellotti, E.; Broggini, C.; Corvisiero, P.; D'Alessandro, A.; Fiorentini, G.; Fubini, A.; Gervino, G.; Greife, U.; Gustavino, C.; Lambert, J.; Prati, P.; Rodney, W.S.; Rolfs, C.; Trautvetter, H.P.; Zavatarelli, S.

    1999-01-01

    We report on the status of the 3 He( 3 He,2p) 4 He experiment at the underground accelerator facility LUNA (Gran Sasso). The lowest projectile energies for the measured cross section correspond already to energies below the center of the solar Gamow peak (E 0 =22 keV). The data provide no evidence for the existence of a hypothetical resonance in the energy range investigated. Although no extrapolation is needed anymore (except for energies at the low-energy tail of the Gamow peak), the data must be corrected for the effects of electron screening, clearly observed the first time for the 3 He( 3 He,2p) 4 He reaction. The effects are however larger than expected and not understood, leading presently to the largest uncertainty on the quoted S(0) value for bare nuclides (= 5.40 MeVb)

  9. Polarized Raman spectroscopic study of relaxed high density amorphous ices under pressure.

    Science.gov (United States)

    Suzuki, Yoshiharu; Tominaga, Yasunori

    2010-10-28

    We have made high density amorphous ice (HDA) by the pressure-induced amorphization of hexagonal ice at 77 K and measured the volume change on isobaric heating in a pressure range between 0.1 and 1.5 GPa. The volume of HDA on heating below ∼0.35 GPa increases, while the volume of HDA on heating above ∼0.35 GPa decreases. The polarized OH-stretching Raman spectra of the relaxed HDAs are compared with that of the unannealed HDA. The relaxed HDAs are prepared at 0.2 GPa at 130 K and 1.5 GPa at 160 K. It is found that the relatively strong totally symmetric OH-stretching vibration mode around 3100 cm(-1) exists in the depolarized reduced Raman spectrum χ(VH)(") of the unannealed HDA and that its intensity rapidly decreases by relaxation. The χ(VH)(") profiles of the relaxed HDA are similar to those of liquid water. These results indicate that the HDA reaches a nearly equilibrium state by annealing and the intrinsic state of HDA relates to a liquid state. The pressure-volume curve of the relaxed HDA at 140 K seems to be smooth in the pressure range below 1.5 GPa.

  10. Pressure induced magnetic phase transition in RhFe{sub 3}N and IrFe{sub 3}N: An ab-initio study

    Energy Technology Data Exchange (ETDEWEB)

    Puvaneswari, S. [Department of physics, E.M.G.Yadava women’s college, Madurai, Tamilnadu-625014 (India); Manikandan, M. [Department of physics, N.M.S.S.V.N college, Madurai, Tamilnadu-625019 (India); Rajeswarapalanichamy, R., E-mail: rrpalanichamy@gmail.com

    2016-05-06

    The structural, electronic, elastic and magnetic properties of RhFe{sub 3}N and IrFe{sub 3}N are investigated using ab-initio calculations based on density functional theory as implemented in VASP code within the gradient generalized approximation. The non-spin polarized and spin polarized calculations are performed for these nitrides at normal and high pressures. It is found that these ternary nitrides are stable in ferromagnetic state at normal pressure. The lattice constant and bulk modulus values are calculated. The electronic structure reveals that these nitrides are metallic at normal pressure. The calculated elastic constants indicate that they are mechanically stable at ambient pressure. Ferromagnetic to nonmagnetic phase transition is observed in RhFe{sub 3}N and IrFe{sub 3}N at high pressure. Ferromagnetism is quenched in these nitrides at high pressure.

  11. Study of charge symmetry in 4He by simultaneous 4He(e,e'p)3H and 4He(e,e'n)3He measurements

    International Nuclear Information System (INIS)

    Spahn, M.; Kihm, T.; Knopfle, K.T.; Friedrich, J.; Voegler, N.; Schmitt, C.; Walther, V.H.; Unkelbach, M.; Hofmann, H.M.

    1989-01-01

    We have measured the ( 3 H+p) and ( 3 He+n) breakup of 4 He by 4 He(e,e'c) coincidence experiments at low momentum transfer (q∼0.39 fm -1 ) in the excitation energy region 22≤E x ≤36 MeV. Both channels were studied simultaneously by detecting the charged fragments c=p, 3 H, and 3 He in the same detector system. The measured 4 He(e,e'p) 3 H and 4 He(e,e'n) 3 He angular correlations as well as the deduced total 4 He(e,e'p) 3 H and 4 He(e,e'n) 3 He cross sections are reproduced by microscopic model calculations with a charge-symmetric nuclear Hamiltonian

  12. Boron-coated straws as a replacement for {sup 3}He-based neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lacy, Jeffrey L., E-mail: jlacy@proportionaltech.com [Proportional Technologies, Inc., 8022 El Rio Street, Houston, TX 77054 (United States); Athanasiades, Athanasios; Sun, Liang; Martin, Christopher S.; Lyons, Tom D.; Foss, Michael A.; Haygood, Hal B. [Proportional Technologies, Inc., 8022 El Rio Street, Houston, TX 77054 (United States)

    2011-10-01

    US and international government efforts to equip major seaports with large area neutron detectors, aimed to intercept the smuggling of nuclear materials, have precipitated a critical shortage of {sup 3}He gas. It is estimated that the annual demand of {sup 3}He for US security applications alone is more than the worldwide supply. This is strongly limiting the prospects of neutron science, safeguards, and other applications that rely heavily on {sup 3}He-based detectors. Clearly, alternate neutron detection technologies that can support large sensitive areas, and have low gamma sensitivity and low cost must be developed. We propose a low-cost technology based on long copper tubes (straws), coated on the inside with a thin layer of {sup 10}B-enriched boron carbide ({sup 10}B{sub 4}C). In addition to the high abundance of boron on Earth and low cost of {sup 10}B enrichment, the boron-coated straw (BCS) detector offers distinct advantages over conventional {sup 3}He-based detectors, and alternate technologies such as {sup 10}BF{sub 3} tubes and {sup 10}B-coated rigid tubes. These include better distribution inside moderator assemblies, many-times faster electronic signals, no pressurization, improved gamma-ray rejection, no toxic or flammable gases, and ease of serviceability. We present the performance of BCS detectors dispersed in a solid plastic moderator to address the need for portal monitoring. The design adopts the outer dimensions of currently deployed {sup 3}He-based monitors, but takes advantage of the small BCS diameter to achieve a more uniform distribution of neutron converter throughout the moderating material. We show that approximately 63 BCS detectors, each 205 cm long, distributed inside the moderator, can match or exceed the detection efficiency of typical monitors fitted with a 5 cm diameter {sup 3}He tube, 187 cm long, pressurized to 3 atm.

  13. The polarization of MeV neutrons elastically scattered from 4He

    International Nuclear Information System (INIS)

    Bond, J.E.; Firk, F.W.K.

    1976-01-01

    The analyzing power of 4 He for neutron elastic scattering has been measured at four angles between 20 0 and 80 0 (lab) throughout the energy range 1.5-6.0 MeV using a double-scattering method. The intense flux of polarized neutrons was generated via the reactions Pb(γ, n)→ 12 C(n, n(pol.) 12 C, and the magnitude of the polarization of the neutron beam measured absolutely in a separate double-scattering experiment. Neutron energies were determined with a nanosecond time-of-flight spectrometer, and the generalized neutron spin-precession method was used to minimize systematic uncertainties. (Auth.)

  14. Triton-3He relative and differential flows and the high density behavior of nuclear symmetry

    International Nuclear Information System (INIS)

    Yong, Gaochan; Li, Baoan; Chen, Liewen

    2010-01-01

    Using a transport model coupled with a phase-space coalescence after-burner we study the triton- 3 He relative and differential transverse flows in semi-central 132 Sn + 124 Sn reactions at a beam energy of 400 MeV/nucleon. We find that the triton- 3 He pairs carry interesting information about the density dependence of the nuclear symmetry energy. The t- 3 He relative flow can be used as a particularly powerful probe of the high-density behavior of the nuclear symmetry energy. (author)

  15. The polarization of fast neutrons

    International Nuclear Information System (INIS)

    Talov, V.V.

    2000-01-01

    The present work is the review of polarization of fast neutrons and methods of polarization analysis. This also includes information about polarization of fast neutrons from first papers, which described polarization in the D(d,n) 3 He, 7 Li(p,n) 7 Be, and T(p,n) 3 He reactions. (authors)

  16. Precise measurement of the neutron magnetic form factor from quasielastic 3 rvec He(rvec e,e')

    International Nuclear Information System (INIS)

    Gao, H.

    1997-01-01

    Polarized 3 He targets have proven to be a useful tool for studying the electric and magnetic form factors of the neutron, and the spin structure of the neutron. The neutron magnetic form factor at low Q 2 was determined previously at MIT-Bates from the quasielastic 3 rvec He(rvec e, e ' ) process. New experiment was planned at TJNAF to systematically measure the inclusive 3 He quasielastic transverse asymmetry, A T ' , at Q 2 = 0.1 - 0.5 (GeV/c) 2 with high statistical and systematic accuracy. A 2% statistical uncertainty is aimed at all the pro- posed values of Q 2 , and 3% systematic uncertainty for A T ' can be achieved for this experiment. The precise data will constrain theoretical calculations of 3 He quasielastic asymmetry. Furthermore, the neutron magnetic form factor at Q 2 = 0.1 - 0.5 (GeV/c) 2 will be extracted from the measured asymmetries with an overall uncertainty of 2%. Precise measurements of G n M at low Q 2 will resolve the discrepancy among the existing data in the same Q 2 region

  17. Two-body photodisintegration of {sup 3}He between 7 and 16 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Tornow, W., E-mail: tornow@tunl.duke.edu [Duke University, Durham, NC 27708-0308 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Karwowski, H.J. [University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3255 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Kelley, J.H. [North Carolina State University, Raleigh, NC 27695-8202 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Raut, R.; Rusev, G.; Stave, S.C.; Tonchev, A.P. [Duke University, Durham, NC 27708-0308 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Deltuva, A.; Fonseca, A.C. [Centro de Fisica Nuclear da Universidade de Lisboa, P-1649-003 Lisboa (Portugal); Marcucci, L.E. [Department of Physics, ' Enrico Fermi' , University of Pisa, I-56127 Pisa (Italy); INFN, Sezione di Pisa, I-56100 Pisa (Italy); Viviani, M.; Kievsky, A. [INFN, Sezione di Pisa, I-56100 Pisa (Italy); Golak, J.; Skibinski, R.; Witala, H. [M. Smoluchowski Institute of Physics, Jagiellonian University, PL-30059 Krakow (Poland); Schiavilla, R. [Department of Physics, Old Dominion University, Norfolk, VA 23529 (United States); Thomas Jefferson National Accelerator Facility, Newport News, VA 23606 (United States)

    2011-08-11

    A comprehensive data set is reported for the two-body photodisintegration cross section of {sup 3}He using mono-energetic photon beams at eleven energies between 7.0 and 16.0 MeV. A {sup 3}He+Xe high-pressure gas scintillator served as target and detector. Although our data are in much better agreement with our state-of-the-art theoretical calculations than the majority of the previous data, these calculations underpredict the new data by about 10%. This disagreement suggests an incomplete understanding of the dynamics of the three-nucleon system and its response to electromagnetic probes.

  18. Assessment of the 3He pressure inside the CABRI transient rods - Development of a surrogate model based on measurements and complementary CFD calculations

    Science.gov (United States)

    Clamens, Olivier; Lecerf, Johann; Hudelot, Jean-Pascal; Duc, Bertrand; Cadiou, Thierry; Blaise, Patrick; Biard, Bruno

    2018-01-01

    CABRI is an experimental pulse reactor, funded by the French Nuclear Safety and Radioprotection Institute (IRSN) and operated by CEA at the Cadarache research center. It is designed to study fuel behavior under RIA conditions. In order to produce the power transients, reactivity is injected by depressurization of a neutron absorber (3He) situated in transient rods inside the reactor core. The shapes of power transients depend on the total amount of reactivity injected and on the injection speed. The injected reactivity can be calculated by conversion of the 3He gas density into units of reactivity. So, it is of upmost importance to properly master gas density evolution in transient rods during a power transient. The 3He depressurization was studied by CFD calculations and completed with measurements using pressure transducers. The CFD calculations show that the density evolution is slower than the pressure drop. Surrogate models were built based on CFD calculations and validated against preliminary tests in the CABRI transient system. Studies also show that it is harder to predict the depressurization during the power transients because of neutron/3He capture reactions that induce a gas heating. This phenomenon can be studied by a multiphysics approach based on reaction rate calculation thanks to Monte Carlo code and study the resulting heating effect with the validated CFD simulation.

  19. Assessment of the 3He pressure inside the CABRI transient rods - Development of a surrogate model based on measurements and complementary CFD calculations

    Directory of Open Access Journals (Sweden)

    Clamens Olivier

    2018-01-01

    Full Text Available CABRI is an experimental pulse reactor, funded by the French Nuclear Safety and Radioprotection Institute (IRSN and operated by CEA at the Cadarache research center. It is designed to study fuel behavior under RIA conditions. In order to produce the power transients, reactivity is injected by depressurization of a neutron absorber (3He situated in transient rods inside the reactor core. The shapes of power transients depend on the total amount of reactivity injected and on the injection speed. The injected reactivity can be calculated by conversion of the 3He gas density into units of reactivity. So, it is of upmost importance to properly master gas density evolution in transient rods during a power transient. The 3He depressurization was studied by CFD calculations and completed with measurements using pressure transducers. The CFD calculations show that the density evolution is slower than the pressure drop. Surrogate models were built based on CFD calculations and validated against preliminary tests in the CABRI transient system. Studies also show that it is harder to predict the depressurization during the power transients because of neutron/3He capture reactions that induce a gas heating. This phenomenon can be studied by a multiphysics approach based on reaction rate calculation thanks to Monte Carlo code and study the resulting heating effect with the validated CFD simulation.

  20. Specific-heat measurements on dilute 3He-4He mixtures

    International Nuclear Information System (INIS)

    Zeeuw, H.C.M. van der.

    1985-01-01

    The author measured the specific heat of dilute 3 He- 4 He mixtures in the concentration range from X = 1 x 10 -3 to X = 3 x 10 -3 and in the temperature range from 100 mK to 600 mK. This has been done by means of a thermal relaxation method. This method provides some interesting features and is applied, to our knowledge, for the first time to dilute 3 He- 4 He mixtures. To reach the required temperature range for our experiments a 4 He circulating 3 He- 4 He dilution refrigerator has been constructed. The results confirm the deviation of the 3 He contribution to the specific heat from the ideal Fermi gas behaviour. (Auth.)

  1. Asymmetry in nonmesonic decay of polarized sup 5 subLAMBDA He hypernucleus

    CERN Document Server

    Ajimura, S; Ejiri, H; Hasegawa, T; Hashimoto, O; Ishikawa, M; Ikeda, K; Kim, Y; Kishimoto, T; Maeda, K; Manabe, K; Nagae, T; Nakano, T; Noumi, H; Okusu, A; Park, H; Sekimoto, M; Shibata, T; Shinkai, N; Takahashi, T; Tanaka, Y; Youn, M

    2000-01-01

    We have measured the asymmetric emission of protons and pions from the non mesonic decay of the polarized sup 5 subLAMBDA He produced by the (pi sup + , K sup +) reaction. The polarization was derived by the observed asymmetry of the mesonic decay pions for the first time. The asymmetry parameter of the non mesonic decay has been evaluated using the obtained polarization and the asymmetry of the decay protons. The positive asymmetry parameter contradicts theoretical prediction based on meson exchange model. The discrepancy can be attributed to insufficient knowledge of the weak LAMBDA N interaction, especially at short range, which may consistently explain the discrepancy seen in the partial decay rates of the non mesonic decay.

  2. Electron scattering in dense He-Ar gas mixtures: A pressure shift study

    International Nuclear Information System (INIS)

    Asaf, U.; Felps, W.S.; McGlynn, S.P.

    1989-01-01

    The dependence of the energies of high-n Rydberg states of CH 3 I on the molar composition of helium-argon mixtures (in the number density range 1.3x10 20 --5.6x10 20 cm -3 ) is reported. The energy shifts, when normalized to a given density value, are found to vary linearly with the mole fraction of either component of the binary, rare-gas mixture. The observed change in sign of the energy shift is attributable to the different signs of the electron scattering lengths for the two rare-gas components. As a result, there exists a mixture composition, at a mole ratio [He]/[Ar]=2.0, at which the shift is null. The experimental results for the gas mixture agree with the Fermi formula, as modified to include the Alekseev-Sobel'man polarization term. Effective electron scattering lengths and cross sections, polarizabilities, and thermal velocities are used to characterize the effects of the binary gas perturber system

  3. Role of polarizability in the 3H(d,n)4He reaction

    International Nuclear Information System (INIS)

    Belyaev, V.B.; Kuzmichev, V.E.; Peresypkin, V.V.; Zepalova, M.L.

    1987-01-01

    The influence is investigated of the deuteron electric dipole polarizability on the cross section, astrophysical S-factor, and the yield of helium nuclei in the 3 H(d,n) 4 He reaction in the region of extremely low energies. Prediction is made of the existence of narrow maximum in the cross section at energies of an incident triton lower that 10 keV produced by the action of an attractive polarization potential in the d 3 H system. The growth of the cross section of d 3 H reaction increases the yield of 4 He nuclei at temperatures lower than keV

  4. Nuclear magnetism of liquid {sup 3}He: new determination of the Landau parameter F{sub 0}{sup a}; Magnetisme nucleaire de l'{sup 3}He liquide: nouvelle determination du parametre de Landau F{sup a}{sub 0}

    Energy Technology Data Exchange (ETDEWEB)

    Goudon, V

    2006-10-15

    He{sup 3} is a liquid Fermi model, isotropic, with an attainable Fermi temperature and the interaction between atoms can be controlled by changing the pressure of the liquid. In this document, we present accurate NMR measurements of the nuclear magnetic susceptibility of liquid He{sup 3} as a function of temperature and pressure. The emphasis has been placed on reliable thermometry and on He{sup 3} pressure measurements directly in the cell to increase the measuring range until solidification, and an accurate characterization of the NMR spectrometer. Our measurements give an effective Fermi temperature 5% lower than former results. The Landau parameter F{sub 0}{sup a} depends on the effective mass, which is determined by specific heat measurements, and consequently on the temperature scale. The re-analysis of the specific heat measurements with the PLTS-2000 temperature scale yields an effective mass increase of 4.5%. In this document, F{sub 0}{sup a} is determined for 2 temperature scales (PLTS-2000 and Greywall). Contrarily to former measurements, the F{sub 0}{sup a} density dependence does not show any saturation at high pressures. (author)

  5. Galactic evolution of D and 3He including stellar production of 3He

    International Nuclear Information System (INIS)

    Dearborn, D.S.; Steigman, G.; Tosi, M.

    1996-01-01

    New stellar models which track the production and destruction of 3 He (and D) have been evolved for a range of stellar masses (0.65≤M/M circle-dot ≤100), metallicities (0.01≤Z/Z circle-dot ≤1), and initial (main-sequence) 3 He mass fractions (10 -5 ≤X 3,MS ≤10 -3 ). Armed with the 3 He yields from these stellar models we have followed the evolution of D and 3 He using a variety of chemical evolution models with and without infall of primordial or processed material. Production of new 3 He by the lower mass stars overwhelms any reasonable primordial contributions and leads to predicted abundances in the presolar nebula and/or the present interstellar medium in excess of the observationally inferred values. This result, which obtains even for zero primordial D and 3 He, and was anticipated by Rood, Steigman, ampersand Tinsley is insensitive to the choice of chemical evolution model; it is driven by the large 3 He yields from low-mass stars. In an attempt to ameliorate this problem we have considered a number of nonstandard models in which the yields from low-mass stars have been modified. Although several of these nonstandard models may be consistent with the 3 He data, they may be inconsistent with observations of 12 C/ 13 C, 18 O, and, most seriously the super- 3 He rich planetary nebulae. Even using the most extreme of these nonstandard models we obtain a generous upper bound to pregalactic 3 He:X 3P ≤3.2x10 -5 which, nonetheless, leads to a stringent lower bound to the universal density of nucleons. copyright 1996 The American Astronomical Society

  6. Spin waves at the liquid 3He-4He interface

    International Nuclear Information System (INIS)

    Heff, A.; Candela, D.; Edwards, D.O.; Kumar, S.

    1987-01-01

    The properties of various interfaces in helium and, in particular, the interface between liquid 3 He and a solution of 3 He in 4 He, may be studied using spin waves. Assuming no transverse relaxation, the boundary condition for the transverse magnetization contains one complex kinetic coefficient, b. For the normal 3 He to 3 He- 4 He interface, b is related to the 3 He quasi-particle transmission probability antiτ, which we estimate from a simple model. A calculation of the spin wave absorption spectrum for a typical geometry shows that b and antiτ may be measured by NMR. Neither b nor antiτ is greatly affected when the pure 3 He enters the A phase, but both are strongly reduced in the B phase

  7. Biological Studies with Laser-Polarized ^129Xe

    Science.gov (United States)

    Tseng, C. H.; Oteiza, E. R.; Wong, G. A.; Walsworth, R. L.; Albert, M. S.; Nascimben, L.; Peled, S.; Sakai, K.; Jolesz, F. A.

    1996-05-01

    We have studied several biological systems using laser-polarized ^129Xe. In certain tissues magnetic resonance imaging (MRI) using inhaled laser-polarized noble gases may provide images superior to those from conventional proton MRI. High resolution laser-polarized ^3He images of air spaces in the human lung were recently obtained by the Princeton/Duke group. However, ^3He is not very soluble in tissue. Therefore, we are using laser polarized ^129Xe (tissue-soluble), with the long term goal of biomedical functional imaging. We have investigated multi-echo and multi-excitation magnetic resonance detection schemes to exploit the highly non-thermal ^129Xe magnetization produced by the laser polarization technique. We have inhalated live rats with laser-polarized ^129Xe gas and measured three distinct ^129Xe tissue resonances that last 20 to 40 sec. As a demonstration, we obtained a laser polarized ^129Xe image of the human oral cavity. Currently we are measuring the polarization lifetime of ^129Xe dissolved in human blood, the biological transporting medium. These studies and other recent developments will be reported.

  8. Interspecies Ion Diffusion Studies using DT, DT(3He), and DT(H) Implosions

    Science.gov (United States)

    Kim, Y.; Herrmann, H. W.; Schmitt, M. J.; Kagan, G.; McEvoy, A. M.; Hoffman, N. M.; Gales, S.; Leatherland, A.; Gatu Johnson, M.; Frenje, J.; Glevov, V. Yu; Forrest, C.

    2015-11-01

    Anomalous ICF yield degradation has been observed from gas fills containing mixtures (i.e., D(3He), DT(3He), D(Ar), and even DT). Interspecies ion diffusion theory has been suggested as a possible cause resulting from gradient-driven diffusion (i.e., pressure, electric potential, and temperature) which forces lower mass ions away from core and higher mass ions toward core. The theory predicts hydrogen addition to deuterium or tritium should result in increased yield compared to expected yield, which is opposite to 3He addition. At Omega laser facility, we have tested hydro-equivalent fills of DT, DT(3He), and DT(H) with the assumption that same fuel mass and particle pressure will provide identical convergence. Preliminary results verify a factor of 2 yield reduction relative to scaling when 3He added to DT. At DT(H) case, however, no significant yield degradation or a slight yield enhancement was observed which agrees with the interspecies ion diffusion theory. Detailed experiment results and simulation are needed to confirm the initial observation.

  9. SLC polarized beam source ultra-high-vacuum design

    International Nuclear Information System (INIS)

    Lavine, T.L.; Clendenin, J.E.; Garwin, E.L.; Hoyt, E.W.; Hoyt, M.W.; Miller, R.H.; Nuttall, J.A.; Schultz, D.C.; Wright, D.

    1991-05-01

    This paper describes the design of the ultra-high vacuum system for the beam-line from the 160-kV polarized electron gun to the linac injector in the Stanford Linear Collider (SLC). The polarized electron source is a GaAs photocathode, requiring 10 -11 -Torr-range pressure for adequate quantum efficiency and longevity. The photo-cathode is illuminated by 3-nsec-long laser pulses. Photo-cathode maintenance and improvements require occasional substitution of guns with rapid restoration of UHV conditions. Differential pumping is crucial since the pressure in the injector is more than 10 times greater than the photocathode can tolerate, and since electron-stimulated gas desorption from beam loss in excess of 0.1% of the 20-nC pulses may poison the photocathode. Our design for the transport line contains a differential pumping region isolated by a pair of valves. Exchange of guns requires venting only this isolated region which can be restored to UHV rapidly by baking. The differential pumping is performed by non-evaporable getters (NEGs) and an ion pump. 3 refs., 3 figs

  10. Broad-aperture polarized proton target with arbitrary orientation of polarization vector

    International Nuclear Information System (INIS)

    Belyaev, A.A.; Get'man, V.A.; Derkach, A.Ya.; Karnaukhov, I.M.; Lukhanin, A.A.; Razumnyj, A.A.; Sorokin, P.V.; Sporov, E.A.; Telegin, Yu.N.; Trotsenko, V.I.

    1985-01-01

    Polarized proton target with the Helmholtz broad-aperture superconducting magnetic system is described. Axial aperture α=95 deg, inter-coil access angle β=23 deg. The structure of the target allows various versions of the installation what make sure an arbitrary orientation of polarization vector. The 0.1 W cold output 3 He evaporation cryostat was used to obtain the work temperature 0.5 K allowing quick transformation to a 3 He- 4 He dilution refrigerator. Results of the study are given on the dynamical proton polarization in 1,2-propylenglycol with various stable Cr 5 complexes

  11. On the large COMPASS polarized deuteron target

    CERN Document Server

    Finger, M; Baum, G; Doshita, N; Finger, M Jr; Gautheron, F; Goertz, St; Hasegawa, T; Heckmann, J; Hess, Ch; Horikawa, N; Ishimoto, S; Iwata, T; Kisselev, Y; Koivuniemi, J; Kondo, K; Le Goff, J-M; Magnon, A; Marchand, C; Matsuda, T; Meyer, W; Reicherz, G; Srnka, A

    2006-01-01

    The spin structure of the nucleons is investigated in deep inelastic scattering of a polarized muon beam and a polarized nucleon target in the COMPASS experiment at CERN since 2001. To achieve high luminosities a large solid polarized target is used. The COMPASS polarized target consists of a high cooling power $^{3}$He/$^{4}$He dilution refrigerator capable to maintain working temperature of the target material at about 50mK, a superconducting solenoid and dipole magnet system for longitudinal and transversal magnetic field on the target material, respectively, target cells containing polarizable material, microwave cavities and high power microwave radiation systems for dynamic nuclear polarization and the nuclear magnetic resonance system for nuclear spin polarization measurements. During 2001–2004 experiments superconducting magnet system with opening angle $\\pm$69 mrad, polarized target holder with two target cells and corresponding microwave and NMR systems have been used. For the data taking from 200...

  12. Bubble nucleation dynamics in 3He/4He mixture by holographic interferometry

    International Nuclear Information System (INIS)

    Morikawa, M; Abe, H; Nomura, R; Okuda, Y

    2009-01-01

    We were able to nucleate a gas bubble in the diluted phase of 3 He- 4 He mixture by a 1 ms width strong sound pulse. The nucleated bubble became large and detached from the bottom transducer and was pushed out to the bulk liquid by the acoustic wave pulse. The bubble then repeatedly expanded and contracted a few times and finally disappeared. The overall motion of the bubble was traced by a high speed camera with a time resolution of 1 ms. We are attempting to investigate the small density fluctuation around the bubble by incorporating holographic interferometry technology. The measurement was done at T=0.35 K for the phase separated mixture at saturated vapor pressure. An acoustic wave transducer was located at the bottom of the cell, so the bubble was nucleated in the dilute phase of the mixture. We resolved the density fluctuation as small as Δρ/ρ = 2 x 10 -6 in the dilute phase with the sample width of 25 mm, which could not be obtained by other methods. It was found that there appeared a less dense region of -Δρ/ρ ∼ 1.46 x 10 -3 just above the bubble. The bubble appeared just after the pulse was turned off, but this less dense region appeared prior to the emergence of the bulk bubble. It should be an important information about the bubble nucleation mechanism. This very high sensitivity of holographic interferometry with respect to the density fluctuation could be widely used in quantum liquid.

  13. Nontarget analysis of polar contaminants in freshwater sediments influenced by pharmaceutical industry using ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Terzic, Senka, E-mail: terzic@irb.h [Division of Marine and Environmental Research, Rudjer Boskovic Institute, 10000 Zagreb (Croatia); Ahel, Marijan [Division of Marine and Environmental Research, Rudjer Boskovic Institute, 10000 Zagreb (Croatia)

    2011-02-15

    A comprehensive analytical procedure for a reliable identification of nontarget polar contaminants in aquatic sediments was developed, based on the application of ultra-high-pressure liquid chromatography (UHPLC) coupled to hybrid quadrupole time-of-flight mass spectrometry (QTOFMS). The procedure was applied for the analysis of freshwater sediment that was highly impacted by wastewater discharges from the pharmaceutical industry. A number of different contaminants were successfully identified owing to the high mass accuracy of the QTOFMS system, used in combination with high chromatographic resolution of UHPLC. The major compounds, identified in investigated sediment, included a series of polypropylene glycols (n = 3-16), alkylbenzene sulfonate and benzalkonium surfactants as well as a number of various pharmaceuticals (chlorthalidone, warfarin, terbinafine, torsemide, zolpidem and macrolide antibiotics). The particular advantage of the applied technique is its capability to detect less known pharmaceutical intermediates and/or transformation products, which have not been previously reported in freshwater sediments. - Research highlights: UHPLC-QTOFMS coupling was applied for nontarget analysis of polar contaminants. Wide spectrum of polar contaminants was identified in polluted sediments. Pharmaceuticals and their intermediates were present in high concentrations. - Comprehensive analysis of freshwater sediments by UPLC/QTOF indicated importance of pharmaceutically-derived polar contaminants.

  14. Binary and ternary recombination of D3+ ions with electrons in He-D2 plasma

    Science.gov (United States)

    Glosík, J.; Korolov, I.; Plašil, R.; Kotrík, T.; Dohnal, P.; Novotný, O.; Varju, J.; Roučka, Š.; Greene, Chris H.; Kokoouline, V.

    2009-10-01

    An experimental study is reported about the recombination of D3+ ions with electrons in a low-temperature plasma (200-300 K) consisting of He with a small admixture of D2 . At several temperatures, the pressure dependence of the apparent binary recombination rate coefficient (αeff) was measured over a broad range of helium pressures (200-2000 Pa). The binary and ternary recombination rate coefficients were obtained from measured pressure dependences of αeff . The binary recombination rate coefficient obtained αbin(300K)=(2.7±0.9)×10-8cm3s-1 is in agreement with recent theory. The ternary recombination rate coefficient obtained is KHe(300K)=(1.8±0.6)×10-25cm6s-1 . In analogy with the recently described process of helium-assisted ternary recombination of H3+ ions, it is suggested that the ternary helium-assisted recombination of D3+ ions proceeds through the formation of a neutral long-lived highly excited Rydberg molecule D3 followed by a collision with a He atom.

  15. Discovery of highly spin-polarized conducting surface states in the strong spin-orbit coupling semiconductor Sb2Se3

    Science.gov (United States)

    Das, Shekhar; Sirohi, Anshu; Kumar Gupta, Gaurav; Kamboj, Suman; Vasdev, Aastha; Gayen, Sirshendu; Guptasarma, Prasenjit; Das, Tanmoy; Sheet, Goutam

    2018-06-01

    Majority of the A2B3 -type chalcogenide systems with strong spin-orbit coupling (SOC), such as Bi2Se3,Bi2Te3 , and Sb2Te3 , etc., are topological insulators. One important exception is Sb2Se3 where a topological nontrivial phase was argued to be possible under ambient conditions, but such a phase could be detected to exist only under pressure. In this paper, we show that Sb2Se3 like Bi2Se3 displays a generation of highly spin-polarized current under mesoscopic superconducting point contacts as measured by point-contact Andreev reflection spectroscopy. In addition, we observe a large negative and anisotropic magnetoresistance of the mesoscopic metallic point contacts formed on Sb2Se3 . Our band-structure calculations confirm the trivial nature of Sb2Se3 crystals and reveal two trivial surface states one of which shows large spin splitting due to Rashba-type SOC. The observed high spin polarization and related phenomena in Sb2Se3 can be attributed to this spin splitting.

  16. Preconceptual engineering design for the APT 3He Target/Blanket concept

    International Nuclear Information System (INIS)

    Mensink, D.L.

    1994-01-01

    A preconceptual engineering design has been developed for the 3 He Target/Blanket (T/B) System for the Accelerator Production of Tritium Project. This concept uses an array of pressure tubes containing tungsten rods for the neutron spallation source and 3 He gas contained in a metal tank and blanket tubes as the tritium production material. The engineering design is based on a physics model optimized for efficient tritium production. Principle engineering consideration were: provisions for cooling all materials including the 3 He gas; containment of the gas and radionuclides; remote handling; material compatibility; minimization of 3 He, D 2 O, and activated waste; modularity; and manufacturability. The design provides a basis for estimating the cost to implement the system

  17. Fusion blankets for catalyzed D--D and D--He3 reactors

    International Nuclear Information System (INIS)

    Fillo, J.A.; Powell, J.R.

    1977-01-01

    Blanket designs are presented for catalyzed D-D (Cat-D) and D-He 3 fusion reactors. Because of relatively low neutron wall loads and the flexibility due to non-tritium breeding, blankets potentially should operate for reactor life-times of approximately 30 years. Unscheduled replacement of failed blanket modules should be relatively rapid, due to very low residual activity, by operators working either through access ports in the shield (option 1) or directly in the plasma chamber (option 2). Cat-D blanket designs are presented for high (approximately 30%) and low (approximately 12%) β noncircular Tokamak reactors. The blankets are thick graphite screens, operating at high temperature to anneal radiation damage; the deposited neutron and gamma energy is thermally radiated along internal cavities and conducted to a bank of internal SiC coolant tubes (approximately 4 cm. ID) containing high pressure helium. In the D-He 3 Tokamak reactor design, the blanket consists of multiple layers (e.g., three) of thin (approximately 10 cm.) high strength aluminum (e.g., SAP), modular plates, cooled by organic terphynyl coolant

  18. Fusion blankets for catalyzed D--D and D--3He reactors

    International Nuclear Information System (INIS)

    Fillo, J.A.; Powell, J.R.

    1977-01-01

    Blanket designs are presented for catalyzed D-D (Cat-D) and D-He 3 fusion reactors. Because of relatively low neutron wall loads and the flexibility due to non-tritium breeding, blankets potentially should operate for reactor life-times of approximately 30 years. Unscheduled replacement of failed blanket modules should be relatively rapid, due to very low residual activity, by operators working either through access ports in the shield (option 1) or directly in the plasma chamber (option 2). Cat-D blanket designs are presented for high (approximately 30%) and low (approximately 12%) β non-circular Tokamak reactors. The blankets are thick graphite screens, operating at high temperature to anneal radiation damage; the deposited neutron and gamma energy is thermally radiated along internal cavities and conducted to a bank of internal SiC coolant tubes (approximately 4 cm. ID) containing high pressure helium. In the D-He 3 Tokamak reactor design, the blanket consists of multiple layers (e.g., three) of thin (approximately 10 cm.) high strength aluminum (e.g., SAP), modular plates, cooled by organic terphenyl coolant

  19. Energy dependence of the 3He(3He,π+)6Li reaction

    International Nuclear Information System (INIS)

    Le Bornec, Y.; Hibou, F.; Bimbot, L.; Hennino, T.; Jourdain, J.C.; Reide, F.; Tatischeff, B.; Willis, N.; Aslanides, E.; Bergdolt, G.; Fassnacht, P.; Racca, C.; Boudard, A.; Bruge, G.; Lugol, J.C.

    1983-01-01

    The 3 He( 3 He, π + ) 6 Li reaction has been studied as a function of energy using the 3 He beam at SATURNE. Cross sections for the 6 Li ground state (1 + ) and 2.18 MeV (3 + ) levels have been obtained at 350, 420, 500 and 600 MeV incident energies at angles THETAsub(π)(lab)=15 0 and 40 0 . These results are compared with two theoretical predictions. (orig.)

  20. Burn characteristics of compressed fuel pellets for D-3He inertial fusion

    International Nuclear Information System (INIS)

    Nakao, Y.; Honda, T.; Honda, Y.; Kudo, K.; Nakashima, H.

    1992-01-01

    In this paper, the feasibility of using D- 3 He fuel in inertial confinement fusion is examined by using a hydrodynamics code that includes neutron and charged-particle transport routines. The use of a small amount of deuterium-tritium (D-T) ignitor is indispensable. Burn simulations are made for quasi-isobaric D-T/D- 3 He pellet models compressed to 5000 times the liquid density. Substantial fuel gains (∼500) are obtained from pellets having parameters ρR D-T = 3 g/cm 2 and ρR total = 14 g/cm 2 and a central spark temperature of 5 keV. The amount of driver energy needed to achieve these gains is estimated to be ∼ 30 MJ when the coupling efficiency is 10%. The driver energy requirement can be reduced by using spin-polarized D-T and D- 3 He fuels

  1. A new type of liquid-3He target system using small mechanical refrigerators

    International Nuclear Information System (INIS)

    Kato, S.; Kobayashi, K.; Maruyama, K.; Okuno, H.; Konno, O.; Suda, T.; Maki, T.; Asami, H.; Koizumi, T.

    1991-04-01

    A new type of liquid- 3 He target has been developed for photoabsorption experiments at intermediate energies. Using the cooling power of liquid 4 He at reduced vapour pressure, 3 He gas is liquefied into a cylindrical target cell of 180 ml and is maintained at 2.0 K during the experiment. Evaporated 4 He gas is evacuated by a rotary pump and returned into the 4 He bath in the cryostat, where two small mechanical refrigerators with cooling capacities of 3 W at 4.3 K and 10 W at 20 K are operated for the purpose of 4 He recondensation. A maintenance-free operation of more than 1,000 hours has become possible by adopting the 4 He circulation system. (author)

  2. Measurement of Single Spin Asymmetry in 3He↑(e, e'K±)X from a Transversely Polarized 3He Target

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Yuxiang [Univ. of Science and Technology, Hefei (China)

    2015-05-01

    Spin-dependent observables are a powerful tool to probe the internal structure of the nucleon and to study the dynamics of the strong interaction. Experimental study of the nucleon spin structure has provided us with many exciting and often surprising results. The so-called "spin crisis" in the 1980s revealed the limitation of naive quark-parton models and led to a worldwide effort to study the nucleon spin structure. However, this effort has been focused mainly on the nucleon's longitudinal spin structure. Recently, when the pioneer work revealed the significant role that transverse spin plays in understanding the full structure of the nucleon and in understanding the dynamics of the strong interaction, the study of the transverse spin structure became the new focus of the worldwide effort. Jefferson Lab (JLab) is located at Newport News, VA, US. It is equipped with the continuous electron beam accelerator facility (CEBAF) and four experimental halls: A, B, C and D. The accelerator can provide a continuous electron beam (2 ns beam bunch) with high polarization (up to ~ 90%) and high current (up to ~ 200μA) for fixed target experiments in all experimental halls. Hall A consists of two standard high-resolution spectrometers (HRS): left HRS (LHRS) and right HRS (RHRS). Another spectrometer, the BigBite spectrometer, can be installed on request by certain experiments. The experiment E06-010 ("Transversity Experiment") at JLab Hall A is the first measurement of the transverse spin structure of the neutron using a transversely polarized 3He target and a 5.89 GeV incident electron beam. The experiment measured target single spin asymmetries (SSA) and beam-target double-pin asymmetries (DSA) in semi-inclusive deep-inelastic scattering (SIDIS) and in deep-inelastic scattering (DIS) processes. It also collected inclusive hadron (pion, kaon and proton) production data parasitically. The scattered electrons were detected in the BigBite spectrometer with

  3. Theory of Inclusive Scattering of Polarized Electrons by Polarized $^{3}$He and the Neutron Form Factors

    OpenAIRE

    Atti, C. Ciofi degli; Pace, E.; Salmé, G.

    1993-01-01

    The theory of inclusive lepton scattering of polarized leptons by polarized J = 1/2 hadrons is presented and the origin of different expressions for the polarized nuclear response function appearing in the literature is explained. The sensitivity of the longitudinal asymmetry upon the neutron form factors is investigated.

  4. Single spin asymmetries in charged kaon production from semi-inclusive deep inelastic scattering on a transversely polarized 3He target

    Science.gov (United States)

    Zhao, Y. X.; Wang, Y.; Allada, K.; Aniol, K.; Annand, J. R. M.; Averett, T.; Benmokhtar, F.; Bertozzi, W.; Bradshaw, P. C.; Bosted, P.; Camsonne, A.; Canan, M.; Cates, G. D.; Chen, C.; Chen, J.-P.; Chen, W.; Chirapatpimol, K.; Chudakov, E.; Cisbani, E.; Cornejo, J. C.; Cusanno, F.; Dalton, M. M.; Deconinck, W.; de Jager, C. W.; De Leo, R.; Deng, X.; Deur, A.; Ding, H.; Dolph, P. A. M.; Dutta, C.; Dutta, D.; El Fassi, L.; Frullani, S.; Gao, H.; Garibaldi, F.; Gaskell, D.; Gilad, S.; Gilman, R.; Glamazdin, O.; Golge, S.; Guo, L.; Hamilton, D.; Hansen, O.; Higinbotham, D. W.; Holmstrom, T.; Huang, J.; Huang, M.; Ibrahim, H. F.; Iodice, M.; Jiang, X.; Jin, G.; Jones, M. K.; Katich, J.; Kelleher, A.; Kim, W.; Kolarkar, A.; Korsch, W.; LeRose, J. J.; Li, X.; Li, Y.; Lindgren, R.; Liyanage, N.; Long, E.; Lu, H.-J.; Margaziotis, D. J.; Markowitz, P.; Marrone, S.; McNulty, D.; Meziani, Z.-E.; Michaels, R.; Moffit, B.; Muñoz Camacho, C.; Nanda, S.; Narayan, A.; Nelyubin, V.; Norum, B.; Oh, Y.; Osipenko, M.; Parno, D.; Peng, J.-C.; Phillips, S. K.; Posik, M.; Puckett, A. J. R.; Qian, X.; Qiang, Y.; Rakhman, A.; Ransome, R.; Riordan, S.; Saha, A.; Sawatzky, B.; Schulte, E.; Shahinyan, A.; Shabestari, M. H.; Širca, S.; Stepanyan, S.; Subedi, R.; Sulkosky, V.; Tang, L.-G.; Tobias, A.; Urciuoli, G. M.; Vilardi, I.; Wang, K.; Wojtsekhowski, B.; Yan, X.; Yao, H.; Ye, Y.; Ye, Z.; Yuan, L.; Zhan, X.; Zhang, Y.; Zhang, Y.-W.; Zhao, B.; Zheng, X.; Zhu, L.; Zhu, X.; Zong, X.; Jefferson Lab Hall A Collaboration

    2014-11-01

    We report the first measurement of target single spin asymmetries of charged kaons produced in semi-inclusive deep inelastic scattering of electrons off a transversely polarized 3He target. Both the Collins and Sivers moments, which are related to the nucleon transversity and Sivers distributions, respectively, are extracted over the kinematic range of 0.1

  5. Nonlinear Dichroism in Back-to-Back Double Ionization of He by an Intense Elliptically Polarized Few-Cycle Extreme Ultraviolet Pulse.

    Science.gov (United States)

    Ngoko Djiokap, J M; Manakov, N L; Meremianin, A V; Hu, S X; Madsen, L B; Starace, Anthony F

    2014-11-28

    Control of double ionization of He by means of the polarization and carrier-envelope phase (CEP) of an intense, few-cycle extreme ultraviolet (XUV) pulse is demonstrated numerically by solving the six-dimensional two-electron, time-dependent Schrödinger equation for He interacting with an elliptically polarized XUV pulse. Guided by perturbation theory (PT), we predict the existence of a nonlinear dichroic effect (∝I^{3/2}) that is sensitive to the CEP, ellipticity, peak intensity I, and temporal duration of the pulse. This dichroic effect (i.e., the difference of the two-electron angular distributions for opposite helicities of the ionizing XUV pulse) originates from interference of first- and second-order PT amplitudes, allowing one to probe and control S- and D-wave channels of the two-electron continuum. We show that the back-to-back in-plane geometry with unequal energy sharing is an ideal one for observing this dichroic effect that occurs only for an elliptically polarized, few-cycle attosecond pulse.

  6. Ab Initio Predictions of K, He and Ar Partitioning Between Silicate Melt and Liquid Iron Under High Pressure

    Science.gov (United States)

    Xiong, Z.; Tsuchiya, T.

    2017-12-01

    Element partitioning is an important property in recording geochemical processes during the core-mantle differentiation. However, experimental measurements of element partitioning coefficients under extreme temperature and pressure condition are still challenging. Theoretical modeling is also not easy, because it requires estimation of high temperature Gibbs free energy, which is not directly accessible by the standard molecular dynamics method. We recently developed an original technique to simulate Gibbs free energy based on the thermodynamics integration method[1]. We apply it to element partitioning of geochemical intriguing trace elements between molten silicate and liquid iron such as potassium, helium and argon as starting examples. Radiogenic potassium in the core can provide energy for Earth's magnetic field, convection in the mantle and outer core[2]. However, its partitioning behavior between silicate and iron remains unclear under high pressure[3,4]. Our calculations suggest that a clear positive temperature dependence of the partitioning coefficient but an insignificant pressure effect. Unlike sulfur and silicon, oxygen dissolved in the metals considerably enhances potassium solubility. Calculated electronic structures reveal alkali-metallic feature of potassium in liquid iron, favoring oxygen with strong electron affinity. Our results suggest that 40K could serve as a potential radiogenic heat source in the outer core if oxygen is the major light element therein.­­ We now further extend our technique to partitioning behaviors of other elements, helium and argon, to get insides into the `helium paradox' and `missing argon' problems. References [1] T. Taniuchi, and T. Tsuchiya, Phys.Rev.B. In press [2] B.A. Buffett, H.E. Huppert, J.R. Lister, and A.W. Woods, Geophys.Res.Lett. 29 (1996) 7989-8006. [3] V.R. Murthy, W. Westrenen, and Y. Fei, Nature. 426 (2003) 163-165. [4] A. Corgne, S.Keshav, Y. Fei, and W.F. McDonough, Earth.Planet.Sci.Lett. 256 (2007

  7. On the 3He anomaly in hot subdwarf B stars

    Science.gov (United States)

    Schneider, David; Irrgang, Andreas; Heber, Ulrich; Nieva, Maria F.; Przybilla, Norbert

    2017-12-01

    Decades ago, 3He isotope enrichment in helium-weak B-type main-sequence, in blue horizontal branch and in hot subdwarf B (sdB) stars, i.e., helium-core burning stars of the extreme horizontal branch, were discovered. Diffusion processes in the atmosphere of these stars lead to the observed abundance anomalies. Quantitative spectral analyses of high-resolution spectra to derive photospheric isotopic helium abundance ratios for known 3He sdBs have not been performed yet. We present preliminary results of high-resolution and high S/N spectra to determine the 3He and 4He abundances of nine known 3He sdBs. We used a hybrid local/non-local thermodynamic equilibrium (LTE/NLTE) approach for B-type stars investigating multiple He i lines, including λ4922 Å and λ6678 Å, which show the strongest isotopic shifts in the optical spectral range.We also report the discovery of four new 3He sdBs from the ESO Supernova Progenitor survey. Most of the 3He sdBs cluster in a narrow temperature strip between ˜ 26000 K and ˜ 30000 K and have almost no atmospheric 4He at all. Interestingly, three 3He sdBs show evidence for vertical helium stratification.

  8. On the 3He anomaly in hot subdwarf B stars

    Directory of Open Access Journals (Sweden)

    Schneider David

    2017-12-01

    Full Text Available Decades ago, 3He isotope enrichment in helium-weak B-type main-sequence, in blue horizontal branch and in hot subdwarf B (sdB stars, i.e., helium-core burning stars of the extreme horizontal branch, were discovered. Diffusion processes in the atmosphere of these stars lead to the observed abundance anomalies. Quantitative spectral analyses of high-resolution spectra to derive photospheric isotopic helium abundance ratios for known 3He sdBs have not been performed yet. We present preliminary results of high-resolution and high S/N spectra to determine the 3He and 4He abundances of nine known 3He sdBs. We used a hybrid local/non-local thermodynamic equilibrium (LTE/NLTE approach for B-type stars investigating multiple He i lines, including λ4922 Å and λ6678 Å, which show the strongest isotopic shifts in the optical spectral range.We also report the discovery of four new 3He sdBs from the ESO Supernova Progenitor survey. Most of the 3He sdBs cluster in a narrow temperature strip between ∼ 26000 K and ∼ 30000 K and have almost no atmospheric 4He at all. Interestingly, three 3He sdBs show evidence for vertical helium stratification.

  9. Spin structure of the neutron ({sup 3}He) and the Bjoerken sum rule

    Energy Technology Data Exchange (ETDEWEB)

    Meziani, Z.E. [Stanford Univ., CA (United States)

    1994-12-01

    A first measurement of the longitudinal asymmetry of deep-inelastic scattering of polarized electrons from a polarized {sup 3}He target at energies ranging from 19 to 26 GeV has been performed at the Stanford Linear Accelerator Center (SLAC). The spin-structure function of the neutron g{sub 1}{sup n} has been extracted from the measured asymmetries. The Quark Parton Model (QPM) interpretation of the nucleon spin-structure function is examined in light of the new results. A test of the Ellis-Jaffe sum rule (E-J) on the neutron is performed at high momentum transfer and found to be satisfied. Furthermore, combining the proton results of the European Muon Collaboration (EMC) and the neutron results of E-142, the Bjoerken sum rule test is carried at high Q{sup 2} where higher order Perturbative Quantum Chromodynamics (PQCD) corrections and higher-twist corrections are smaller. The sum rule is saturated to within one standard deviation.

  10. Second sound velocities in superfluid 3He-4He solutions

    International Nuclear Information System (INIS)

    Dikina, L.S.; Kotenev, G.Ya.; Rudavskij, Eh.Ya.

    1978-01-01

    The velocities of the second sound in the superfluid He 3 -He 4 solutions were measured by the pulse method in the range of temperatures from 1.3 K to Tsub(lambda) and for He 3 concentrations up to 13%.The results obtained supplemented by those available before give the complete description of the concentration and temperature dependences of the second sound velocity in superfluid He 3 -He 4 solutions. The comprehensive comparison of the experimental data on the velocity of the second sound with the theoretical calculations for the superfluid solutions with arbitrary content of He 3 is performed. The good agreement is found between experiment and the theory. The experimental data obtained are used for determination of the potential, which determines the properties of the superfluid solutions

  11. Nontarget analysis of polar contaminants in freshwater sediments influenced by pharmaceutical industry using ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry

    International Nuclear Information System (INIS)

    Terzic, Senka; Ahel, Marijan

    2011-01-01

    A comprehensive analytical procedure for a reliable identification of nontarget polar contaminants in aquatic sediments was developed, based on the application of ultra-high-pressure liquid chromatography (UHPLC) coupled to hybrid quadrupole time-of-flight mass spectrometry (QTOFMS). The procedure was applied for the analysis of freshwater sediment that was highly impacted by wastewater discharges from the pharmaceutical industry. A number of different contaminants were successfully identified owing to the high mass accuracy of the QTOFMS system, used in combination with high chromatographic resolution of UHPLC. The major compounds, identified in investigated sediment, included a series of polypropylene glycols (n = 3-16), alkylbenzene sulfonate and benzalkonium surfactants as well as a number of various pharmaceuticals (chlorthalidone, warfarin, terbinafine, torsemide, zolpidem and macrolide antibiotics). The particular advantage of the applied technique is its capability to detect less known pharmaceutical intermediates and/or transformation products, which have not been previously reported in freshwater sediments. - Research highlights: → UHPLC-QTOFMS coupling was applied for nontarget analysis of polar contaminants. → Wide spectrum of polar contaminants was identified in polluted sediments. → Pharmaceuticals and their intermediates were present in high concentrations. - Comprehensive analysis of freshwater sediments by UPLC/QTOF indicated importance of pharmaceutically-derived polar contaminants.

  12. Performance of a mass spectrometer for determining low tritium levels from 3He/4He measurements

    International Nuclear Information System (INIS)

    Lynch, M.C.F.; Kay, D.J.

    1981-01-01

    The Micromass 3000 mass spectrometer is based on Clarke's 3 He/ 4 He instrument of McMaster University. The principal special features of the MM3000 are: (i) The double collector system, which uses an electron multiplier for the small 3 He + ion beams and a conventional Faraday detector for 4 He + ; (ii) The high sensitivity ion source; and (iii) The low-volume analyser tube employing static vacuum techniques. The sensitivity, resolution and background of the system are designed to permit measurement of 3 He and 4 He levels of the order of 10 -12 cm 3 STP and 10 -6 cm 3 STP, respectively, with a precision of 0.5%, although smaller quantities are detectable. The inherent resolution of the instrument is well in excess of 2000, but a resolution of 600-1000 is normally used for the 3 He + collector as this is sufficient to separate 3 He + from any interfering HD + or H + 3 ions. At this resolution 900 ions per second of 3 He + ions are obtained from 10 -12 cm 3 STP of 3 He. This is the size of 3 He samples obtained from water samples containing tritium at levels around 200 tritium units (1 tritium unit (TU) = IT/10 18 H). At lower tritium levels the 3 He + signal is correspondingly reduced, but the same techniques (described below) allow signals from 1-TU samples (5 ions/s) to be measured with good precision. The limit of detection is reached with quantities of 3 He in the region of 10 -15 cm 3 STP and tritium levels of around 0.1 TU. (author)

  13. Third sound resonance studies of 3He-4He mixture films

    International Nuclear Information System (INIS)

    Heinrichs, R.M.

    1985-01-01

    Third sound velocity and dissipation measurements were performed on 3 He- 4 He mixture films of 3.6 and 5.3 layers 4 He and up to 3 added layers 3 He in the temperature range 0.05-0.3 K using third sound resonance techniques. The 3 He concentration dependence of the velocity was in excellent agreement with a simple layered film model down to the lowest concentrations studied. At the higher 3 He concentrations, the velocity began to deviate from the model, rising above it. The concentration dependence of the dissipation showed some unique structure with a maximum at 0.3-0.5 layers added 3 He for both 4 He coverages. The third sound velocity in the low concentration mixture films had very little temperature dependence in the range studied. The dissipation, however, had some definite temperature dependent structure that evolved with concentration. This evolution was most pronounced at concentrations near the dissipation maximum and eventually became exponential at the higher coverages. Fitting these exponentials produced estimates of the difference in binding energy for the 3 He states in and on the film. In this higher 3 He concentration regime, a temperature dependence of the velocity was observed that began as a small peak at about 0.15 K and eventually became a step at the highest concentrations studied. The exponential nature of the dissipation became clouded when the velocity evolved into this last behavior

  14. Coherent deeply virtual Compton scattering off 3He and neutron generalized parton distributions

    Directory of Open Access Journals (Sweden)

    Rinaldi Matteo

    2014-06-01

    Full Text Available It has been recently proposed to study coherent deeply virtual Compton scattering (DVCS off 3He nuclei to access neutron generalized parton distributions (GPDs. In particular, it has been shown that, in Impulse Approximation (IA and at low momentum transfer, the sum of the quark helicity conserving GPDs of 3He, H and E, is dominated by the neutron contribution. This peculiar result makes the 3He target very promising to access the neutron information. We present here the IA calculation of the spin dependent GPD H See Formula in PDF of 3He. Also for this quantity the neutron contribution is found to be the dominant one, at low momentum transfer. The known forward limit of the IA calculation of H See Formula in PDF , yielding the polarized parton distributions of 3He, is correctly recovered. The extraction of the neutron information could be anyway non trivial, so that a procedure, able to take into account the nuclear effects encoded in the IA analysis, is proposed. These calculations, essential for the evaluation of the coherent DVCS cross section asymmetries, which depend on the GPDs H,E and H See Formula in PDF , represent a crucial step for planning possible experiments at Jefferson Lab.

  15. X-ray Debye-Waller factor measurements of solid 3He and 4He

    International Nuclear Information System (INIS)

    Arms, D.A.; Shah, R.S.; Simmons, R.O.

    2003-01-01

    X-ray synchrotron radiation was used to measure Debye-Waller factors of helium crystals for both 3 He and 4 He in both hcp and fcc phases. To our knowledge, there are no previous measurements for 3 He. The ranges studied for 3 He and 4 He crystals were 11.52-12.82 and 10.95-12.13 cm 3 , respectively, and 11.5-18.2 and 12.0-20.3 K. With small uncertainty, only a Gaussian dependence upon momentum transfer Q was found, and no anisotropy was detected in the hcp phase. Mean square atomic deviations, 2 >, and Lindemann ratios were obtained. Large Lindemann ratios confirm that these solids are highly anharmonic. The 2 > values agree within an average 1% with computations of Draeger and Ceperley from path integral Monte Carlo methods including unusual extrapolations to the thermodynamic limit. Because the path-integral Monte Carlo (PIMC) computations exhibit a T 3 dependence for 2 >, which also depends upon molar volume, an empirical analysis was made of the present data as well as of published x-ray and neutron data on hcp 4 He. The volume dependencies are similar to those found from calorimetry, over a large volume range, and the temperature dependencies show similar systematic variations with molar volume both in x-ray data and PIMC results

  16. Cryogenic polarized target facility: status

    International Nuclear Information System (INIS)

    Gould, C.; Nash, H.K.; Roberson, N.; Schneider, M.; Seagondollar, W.; Soderstrum, J.

    1985-01-01

    The TUNL cryogenically polarized target facility consists of a 3 He- 4 He dilution refrigerator and a superconducting magnet, together capable of maintaining samples at between 10 and 20 mK in magnetic fields up to 7 Tesla. At these temperatures and magnetic fields brute-force nuclear orientation occurs. Polarizations from 20 to 60% are attainable in about twenty nonzero spin nuclei. Most are metals, ranging in mass from 6 Li to 209 Bi, but the nuclei 1 H and 3 He are also polarizable via this method. The main effort is directed towards a better determination of the effective spin-spin force in nuclei. These experiments are briefly described and the beam stabilization system, cryostat and polarized 3 He targets are discussed

  17. The helium flux from the continents and ubiquity of low-3He/4He recycled crust and lithosphere

    Science.gov (United States)

    Day, James M. D.; Barry, Peter H.; Hilton, David R.; Burgess, Ray; Pearson, D. Graham; Taylor, Lawrence A.

    2015-03-01

    New helium isotope and trace-element abundance data are reported for pyroxenites and eclogites from South Africa, Siberia, and the Beni Bousera Massif, Morocco that are widely interpreted to form from recycled oceanic crustal protoliths. The first He isotope data are also presented for Archaean peridotites from the Kaapvaal (South Africa), Slave (Canada), and Siberian cratons, along with recently emplaced off-craton peridotite xenoliths from Kilbourne Hole, San Carlos (USA) and Vitim (Siberia), to complement existing 3He/4He values obtained for continental and oceanic peridotites. Helium isotope compositions of peridotite xenoliths vary from 7.3 to 9.6 RA in recently (volcanics that contain a contribution from asthenospheric sources. Using the new He isotope data for cratonic peridotites and assuming that significant portions (>50%) of the Archaean and Proterozoic continental lithospheric mantle are stable and unaffected by melt or fluid infiltration on geological timescales (>0.1 Ga), and that U and Th contents vary between cratonic lithosphere and non-cratonic lithosphere, calculations yield a 3He flux of 0.25-2.2 atoms/s/cm2 for the continental lithospheric mantle. These estimates differ by a factor of ten from non-cratonic lithospheric mantle and are closer to the observed 3He flux from the continents (<1 atoms/s/cm2). Pyroxenites and eclogites from the continental regions are all characterized by 3He/4He (0.03-5.6 RA) less than the depleted upper mantle, and relatively high U and Th contents. Together with oceanic and continental lithospheric peridotites, these materials represent reservoirs with low time-integrated 3He/(U + Th) in the mantle. Pyroxenites and eclogites are also characterized by higher Fe/Mg, more radiogenic Os-Pb isotope compositions, and more variable δ18O values (∼3‰ to 7‰), compared with peridotitic mantle. These xenoliths are widely interpreted to be the metamorphic/metasomatic equivalents of recycled oceanic crustal protoliths. The

  18. Time reversal tests in polarized neutron reactions

    International Nuclear Information System (INIS)

    Asahi, Koichiro; Bowman, J.D.; Crawford, B.

    1998-01-01

    This is the final report of a three-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). In recent years the nuclear weak interaction has been studied in the compound nucleus via parity violation. The observed parity-violating effects are strongly enhanced by nuclear structure. The predictions are that the interaction of polarized neutrons with polarized nuclear targets could be also used to perform sensitive tests of time-reversal-violation because of the nuclear enhancements. The author has designed experiments to search for time-reversal violation in neutron-nucleus interactions. He has also developed techniques to polarize neutrons with laser-polarized 3 He gas targets. Using the polarized 3 He neutron spin filter, he has performed two experiments at LANSCE: an absolute neutron beam polarization measurement with an accuracy of 0.2--0.3% and a neutron spin-rotation measurement on a 139 La sample

  19. Probing HeII Reionization at z>3.5 with Resolved HeII Lyman Alpha Forest Spectra

    Science.gov (United States)

    Worseck, Gabor

    2017-08-01

    The advent of GALEX and COS have revolutionized our view of HeII reionization, the final major phase transition of the intergalactic medium. COS spectra of the HeII Lyman alpha forest have confirmed with high confidence the high HeII transmission that signifies the completion of HeII reionization at z 2.7. However, the handful of z>3.5 quasars observed to date show a set of HeII transmission 'spikes' and larger regions with non-zero transmission that suggest HeII reionization was well underway by z=4. This is in striking conflict with predictions from state-of-the-art radiative transfer simulations of a HeII reionization driven by bright quasars. Explaining these measurements may require either faint quasars or more exotic sources of hard photons at z>4, with concomitant implications for HI reionization. However, many of the observed spikes are unresolved in G140L spectra and are significantly impacted by Poisson noise. Current data cannot reliably probe the ionization state of helium at z>3.5.We request 41 orbits to obtain science-grade G130M spectra of the two UV-brightest HeII-transmitting QSOs at z>3.5 to confirm and resolve their HeII transmission spikes as an unequivocal test of early HeII reionization. These spectra are complemented by recently obtained data from 8m telescopes: (1) Echelle spectra of the coeval HI Lya forest to map the underlying density field that modulates the HeII absorption, and (2) Our dedicated survey for foreground QSOs that may source the HeII transmission. Our recent HST programs revealed the only two viable targets to resolve the z>3.5 HeII Lyman alpha forest, and to conclusively solve this riddle.

  20. Target correlation and polarization effects on the electron impact ionization of He atoms

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Hari P, E-mail: hps1@physics.ucf.edu [Physics Department, University of Central Florida, Orlando, FL 32816 (United States)

    2011-03-28

    We have reported here the results of our investigation of the effects of electron correlation and polarization of the target in the incident channel on the electron impact ionization of the helium atom. The triple differential cross section (TDCS) is calculated for 28.6 eV incident electron energy for the case when the two final-state outgoing electrons share 4.0 eV excess energy equally and unequally and leave in the opposite direction. The electron correlation and polarization of the He-target in the initial state are considered completely ab initio using the recently extended multiconfiguration Hartree-Fock method. The electron correlation between the two outgoing electrons in the final state is included through the variationally determined screening potential. It is found that both target correlation and polarization in the incident channel play an important role; the polarization has larger effect on the TDCS than the target correlation. We compared our results with available experimental and theoretical data.

  1. Pressure drop and He II flow through fine mesh screens

    Science.gov (United States)

    Maddocks, J. R.; van Sciver, S. W.

    1989-05-01

    Fluid acquisition systems for He II transfer devices will utilize gallery arms to ensure that the fluid encounters the pump inlet. In near term experiments such as Superfluid Helium on Orbit Transfer (SHOOT), the preferred configuration consists of several rectangular channels which have one side made from a Dutch weave stainless steel screen having 325 x 2300 wires per inch. The effective pore diameter for this screen is about 5 microns. The present paper reports on measurements of pressure drop across a screen when it is subjected to a flow of liquid helium. The experiment measures the time rate of change of the level in two different helium reservoirs connected by a screen-blocked channel. Results with normal helium are compared with predictions based on the Armour-Cannon (1968) equations. The He II data show considerable deviation from the classical result. A discussion of the He II pressure drop results in terms of two fluid hydrodynamics is included.

  2. Role of interfaces on the trapping of He in 2D and 3D Cu–Nb nanocomposites

    International Nuclear Information System (INIS)

    Lach, Timothy G.; Ekiz, Elvan H.; Averback, Robert S.; Mara, Nathan A.; Bellon, Pascal

    2015-01-01

    The role of interface structure on the trapping of He in Cu–Nb nanocomposites was investigated by comparing He bubble formation in nano-multilayers grown by PVD, nanolaminates fabricated by accumulative roll bonding (ARB), and 3D nanocomposites obtained by high pressure torsion (HPT). All samples were implanted with 1 MeV He ions at room temperature and characterized by cross section transmission electron microscopy (TEM). The critical He concentration leading to bubble formation was determined by correlating the He bubble depth distribution detected by TEM with the implanted He depth profile obtained by SRIM. The critical He dose per unit interfacial area for bubble formation was largest for the PVD multilayers, lower by a factor of ∼1.4 in the HPT nanocomposites annealed at 500 °C, and lower by a factor of ∼4.6 in the ARB nanolaminates relative to the PVD multilayers. The results indicate that the (111)FCC||(110)BCC Kurdjumov-Sachs (KS) interfaces predominant in PVD and annealed HPT samples provide more effective traps than the (112)KS interfaces predominant in ARB nanolaminates; however, the good trapping efficiency and high interface area of 3D HPT structures make them most attractive for applications. - Highlights: • Cu–Nb nanocomposites with varying interface structure were implanted with He. • PVD multilayers trap the most He per interfacial area before bubbles form. • ARB nanolaminates held ∼4.6 times less He relative to the PVD multilayers. • 3D nanocomposites with high interface area can trap more He than 2D nanocomposites. • Interface structure and interfacial area density play key role in trapping He.

  3. High-resolution thermal expansion measurements under helium-gas pressure

    Science.gov (United States)

    Manna, Rudra Sekhar; Wolf, Bernd; de Souza, Mariano; Lang, Michael

    2012-08-01

    We report on the realization of a capacitive dilatometer, designed for high-resolution measurements of length changes of a material for temperatures 1.4 K ⩽ T ⩽ 300 K and hydrostatic pressure P ⩽ 250 MPa. Helium (4He) is used as a pressure-transmitting medium, ensuring hydrostatic-pressure conditions. Special emphasis has been given to guarantee, to a good approximation, constant-pressure conditions during temperature sweeps. The performance of the dilatometer is demonstrated by measurements of the coefficient of thermal expansion at pressures P ≃ 0.1 MPa (ambient pressure) and 104 MPa on a single crystal of azurite, Cu3(CO3)2(OH)2, a quasi-one-dimensional spin S = 1/2 Heisenberg antiferromagnet. The results indicate a strong effect of pressure on the magnetic interactions in this system.

  4. Quenching of 4He(21S,21P) and 3He(21S,21P) states by collisions with Ne(1S0) atoms

    International Nuclear Information System (INIS)

    Blagoev, K.B.; Dimova, E.; Petrov, G.M.

    2004-01-01

    The cross sections and rate constants for quenching 4 He(2 1 S), 4 He(2 1 P), 3 He(2 1 S) and 3 He(2 1 P) states by collisions with ground state Ne atoms are measured by a time-resolved method in a He-Ne electron beam excited plasma at low pressure. These rate constants at T g =600 K are: k 4 He(2 1 S) =(1.6±0.2)x10 -10 , k 4 He(2 1 P) =(3.4±2.5)x10 -10 , k 3 He(2 1 S) =(1.6±0.2)x10 -10 and k 3 He(2 1 P) =(5.7±1.2)x10 -10 cm 3 s -1 . The cross sections derived from the rate constant are σ 4 He(2 1 S) =(8.4±0.8)x10 -16 , σ 4 He(2 1 P) =(1.8±1.3)x10 -15 , σ 3 He(2 1 S) =(7.1±0.9)x10 -16 and σ 3 He(2 1 P) =(2.6±0.5)x10 -15 cm 2 , respectively. The diffusion coefficient of 3 He(2 1 S) in 3 He is estimated to be D 3 He(2 1 S)- 3 He =1.9D 4 He(2 1 S)- 4 He , based on comparison with 4 He. A time-dependent collisional radiative model for an e-beam sustained He-Ne plasma is developed and the predicted line intensity of NeI λ=6328 A line is compared with the experimental data. The influence of different processes involved in population and depopulation dynamics of He(2 1 S) state are evaluated

  5. The 3He Supply Problem

    Energy Technology Data Exchange (ETDEWEB)

    Kouzes, Richard T.

    2009-05-01

    One of the main uses for 3He is in gas proportional counters for neutron detection. Radiation portal monitors deployed for homeland security and non-proliferation use such detectors. Other uses of 3He are for research detectors, commercial instruments, well logging detectors, dilution refrigerators, for targets or cooling in nuclear research, and for basic research in condensed matter physics. The US supply of 3He comes almost entirely from the decay of tritium used in nuclear weapons by the US and Russia. A few other countries contribute a small amount to the world’s 3He supply. Due to the large increase in use of 3He for homeland security, the supply has dwindled, and can no longer meet the demand. This white paper reviews the problems of supply, utilization, and alternatives.

  6. Studies of electron transitions using solid He pressure techniques

    International Nuclear Information System (INIS)

    Schirber, J.E.

    1977-01-01

    Changes in the topology of the Fermi surfaces of metals occur with variation of temperature or stoichiometry in a number of metallic systems of current interest. Pressure generated by a variety of techniques has proven to be the most useful experimental variable in the study of these transitions, but in most cases only solid He techniques yield sufficiently hydrostatic conditions to permit direct measurements of the Fermi surface as a function of pressure

  7. Dynamics of phase-separated 3He-4He films

    International Nuclear Information System (INIS)

    Kurihara, Susumu

    1982-01-01

    A froehlich-type Hamiltonian is derived for third sound and 3 He quasi particles in phase-separated double layer of superfluid 4 He and normal 3 He liquid. It is stressed that our system is unique and valuable in that characteristic parameters can be varied in a wide range, simply by adjusting the film thickness. The effect of fermion-boson coupling on the velocity and damping of the third sound is examined. It is predicted that a rather drastic change in the third sound spectrum will occur when the Fermi velocity of 3 He system and the third sound velocity are nearly the same. It is pointed out that the system under consideration may show a variety of interesting phenomena, in addition to the softening of the third sound. (author)

  8. Searches for Lorentz violation in {sup 3}He/{sup 129}Xe clock comparison experiments

    Energy Technology Data Exchange (ETDEWEB)

    Allmendinger, F. [Universitaet Heidelberg, Physikalisches Institut (Germany); Burghoff, M. [Physikalisch-Technische Bundesanstalt (Germany); Heil, W., E-mail: wheil@uni-mainz.de; Karpuk, S. [Johannes-Gutenberg Universitaet, Institut fuer Physik (Germany); Kilian, W.; Knappe-Grueneberg, S.; Mueller, W. [Physikalisch-Technische Bundesanstalt (Germany); Schmidt, U. [Universitaet Heidelberg, Physikalisches Institut (Germany); Schnabel, A.; Seifert, F. [Physikalisch-Technische Bundesanstalt (Germany); Sobolev, Yu [Johannes-Gutenberg Universitaet, Institut fuer Physik (Germany); Trahms, L. [Physikalisch-Technische Bundesanstalt (Germany); Tullney, K. [Johannes-Gutenberg Universitaet, Institut fuer Physik (Germany)

    2013-03-15

    We discuss the design and performance of a very sensitive low-field magnetometer based on the detection of free spin precession of gaseous, nuclear polarized {sup 3}He or {sup 129}Xe samples with a SQUID as magnetic flux detector. Characteristic spin precession times T{sub 2}{sup Asterisk-Operator} of up to 115 h were measured in low magnetic fields (about 1 {mu}T) and in the regime of motional narrowing. With the detection of the free precession of co-located {sup 3}He/{sup 129}Xe nuclear spins (clock comparison), the device can be used as ultra-sensitive probe for non-magnetic spin interactions, since the magnetic dipole interaction (Zeeman-term) drops out in the weighted frequency difference, i.e., {Delta}{omega} = {omega}{sub He} - {gamma}{sub He}/{gamma}{sub Xe}{center_dot}{omega}{sub Xe}. We report on searches for Lorentz violating signatures by monitoring the Larmor frequencies of co-located {sup 3}He/{sup 129}Xe spin samples as the laboratory reference frame rotates with respect to distant stars (sidereal modulation).

  9. Helium solubility and bubble growth in metals under high pressure

    International Nuclear Information System (INIS)

    Laakmann, J.

    1985-07-01

    Helium solubility and bubble growth in metals under high pressure polycrystals and single crystals of gold were heated in helium at temperatures between 475 K and 1250 K in a pressure regime of 200 to 2700 bar to measure the solubility of helium in gold. After quenching to room temperature the helium content, measured by mass spectrometry, showed the following properties: 1) A linear dependence of the He solubility on pressure. 2) Thinning of the specimen reduces the helium content by a factor 10 to 100 but does not change the linear pressure dependence. 3) The thermal release of He from thinned polycrystals and single crystals occurs mainly in a single peak at 500 K. 4) The He concentration of the thinned single crystals was lower by a factor of 10 to 50 than that of the thinned polycrystals. 5) The He solubility in single crystals can be described by an enthalpy of solution Hsub(s)sup(f) = 0.85 +- 0.7 eV and a non-configurational entropy of Ssub(s)sup(f) between 0 k and 1 k (k: Boltzmann-constant). In order to measure the pressure dependence of helium bubble growth in nickel polycrystal Ni-foils were α-implanted to a helium content of 130 appm. The evaluation of the size distribution of the helium bubbles after heat treatments shows 1) The helium content of the observable bubbles - assumed to be in equilibrium - equals the amount of helium implanted into the specimen. 2) The activation energy for the growth of helium bubbles is 1.25 +- 0.3 eV. The comparison of specimen which had been heated at low pressures up to 10 bar with others heated at 2500-2700 bar does not show an unequivocal pressure dependence for helium bubble growth. (orig./IHOE) [de

  10. Multiple scattering effects in fast neutron polarization experiments using high-pressure helium-xenon gas scintillators as analyzers

    International Nuclear Information System (INIS)

    Tornow, W.; Mertens, G.

    1977-01-01

    In order to study multiple scattering effects both in the gas and particularly in the solid materials of high-pressure gas scintillators, two asymmetry experiments have been performed by scattering of 15.6 MeV polarized neutrons from helium contained in stainless steel vessels of different wall thicknesses. A monte Carlo computer code taking into account the polarization dependence of the differential scattering cross sections has been written to simulate the experiments and to calculate corrections for multiple scattering on helium, xenon and the gas containment materials. Besides the asymmetries for the various scattering processes involved, the code yields time-of-flight spectra of the scattered neutrons and pulse height spectra of the helium recoil nuclei in the gas scintillator. The agreement between experimental results and Monte Carlo calculations is satisfactory. (Auth.)

  11. Inelastic neutron scattering from high-density fcc 4He

    International Nuclear Information System (INIS)

    Thomlinson, W.; Eckert, J.; Shirane, G.

    1978-01-01

    The phonon dispersion relations in high-density crystals of fcc 4 He have been measured along high-symmetry directions by the neutron-inelastic-scattering technique. A recent study of the lattice dynamics of fcc 4 He by Eckert et al. has been extended to cover the fcc phase diagram at pressures below 5 kbar. Molar volumes of 9.03, 9.43, and 9.97 cm 3 /mole have been studied in the temperature range from near the melting curve to near the fcc-hcp transition line. The phonon dispersion relations are in good agreement with a first-order self-consistent phonon theory calculation by Goldman. The observed phonon-group line shapes at large energy and momentum transfers show evidence for multiphonon scattering in agreement with calculations by Glyde. Eckert et al. reported extremely large anharmonic isochoric temperature shifts of the phonon energies. The present work studied the shifts as a function of molar volume and temperature. Mode-Grueneisen-parameter dispersion curves have been measured using the present data and earlier measurements at lower density in the fcc phase by Traylor et al. Macroscopic Grueneisen parameters have been calculated from the phonon density of states obtained from the data

  12. Cosmogenic 3He in detrital gold

    Science.gov (United States)

    Stuart, Finlay; Yakubovich, Olga; Caracedo, Ana; Nesterenok, Alexander

    2017-04-01

    Since the measurement of cosmogenic He in an alluvial diamond by McConville and Reynolds (1996) the application of cosmogenic noble gases to individual detrital grains to quantify surface processes has not been vigorously pursued. The likely low rate of diffusion of cosmogenic He in native metals, and their resistance to weathering and disintegration during erosion and transport, makes them a potential record of long-term Earth surface processes. In an effort to assess the extent that detrital refractory metals record the exposure history during transport and storage we have undertaken a reconnaissance study of the He isotope composition in 18 grains (2-200 mg) of native gold, copper, silver, and PtPd, Pt3Fe and OsIr alloys from alluvial placer deposits from around the world. 4He is dominantly the result of U and Th decay within the grains, or decay of 190Pt in the Pt-rich alloys. 3He is measurable in 13 grains, concentrations range up to 2.7E+6 atoms/g. 3He/4He are always in excess of the crustal radiogenic ratio, up to 306 Ra. Although nucleogenic 3He produced by (n,α) reactions on 6Li, and 3He from trapped hydrothermal fluids, are present, the majority of the 3He is cosmogenic in origin. Using newly calculated cosmogenic 3He production rates in heavy metals, and a determination of the effect of implantation based on the stopping distances of spallogenic 3He and 3H, the grains have 3Hecos concentrations that are equivalent to 0.35 to 1.5 Ma exposure at Earth's surface. In a study of detrital gold grains from several sites in Scotland we have found that 10 % have 3He concentrations that are significantly in excess of that generated since the Last Glacial Maximum. These studies demonstrate that, with refinement, cosmogenic 3He in refractory detrital minerals can be used to quantify sediment transport and storage on the 1-10 Ma timescale. P. McConville & J.H. Reynolds (1989). Geochim. Cosmochim. Acta, 53, 2365-75.

  13. Annihilation of antiprotons at rest in 3He and 4He

    International Nuclear Information System (INIS)

    Balestra, F.; Bossolasco, S.; Bussa, M.P.; Busso, L.; Fava, L.; Ferrero, L.; Panzieri, D.; Piragino, G.; Tosello, F.; Bendiscioli, G.; Rotondi, R.; Salvini, P.; Zenoni, A.; Batusov, Y.A.; Bunyatov, S.A.; Falomkin, I.V.; Nichitiu, F.; Pontecorvo, G.B.; Sapozhnikov, M.G.; Tretyak, V.I.; Guaraldo, C.; Maggiora, A.; Haatuft, A.; Halsteinslid, A.; Myklebost, K.; Olsen, J.M.; Breivik, F.O.; Jacobsen, T.; Sorensen, S.O.

    1987-01-01

    At LEAR of CERN the annihilation of antiprotons stopping in 3 He and 4 He filling a self shunted streamer chamber in magnetic field has been studied. The relative probabilities of π - production in anti p 3 He and anti p 4 He annihilation events have been obtained. The ratio between the anti p annihilation probability on the neutron and on the proton for 3 He and 4 He has been deduced to be about half the value obtained for 2 H in bubble chamber experiments. The analysis of the results shows this difference cannot be ascribed only to the pion final state interaction or to the shadow effect of the nucleons in the nuclei. 9 refs.; 2 figs

  14. (3He,xn), (3He,pxn) and (3He, fission) reactions on 206Pb between 80 and 200MeV

    International Nuclear Information System (INIS)

    Andre, C.; Gauvin, H.; Le Beyec, Y.; Porile, N.T.

    1976-01-01

    The reactions induced in 206 Pb by 3 He particles having energies between 80 and 200MeV have been studied. Excitation functions for ( 3 He,xn) with x=3 to 14 and for ( 3 He,pxn) with x=2 to 5 have been obtained. Angular distributions of fission fragments were measured at 100, 125, 150 and 175MeV and total fission cross-sections were deduced from the data. On the basis of these results, analysis is attempted to examine the characteristics of reaction mechanisms. From these results it is concluded that non-compound processes play an important role in the reactions. Two features are characteristic of these processes: large cross-sections for charged particle emission and angular distribution of fission fragments closed to isotropy in the laboratory system. In the energy range 25 to 45MeV/nucleon, a comparison was made between the present results and those from an experimental study of α-particle induced reactions on 206 Pb. Also a comparison was made with an α-nucleus collision model applied to 206 Pb. All the observations strongly suggest a breakup of the projectile 3 He followed by the interactions of the fragments with the target nucleus [fr

  15. High-pressure U3O8 with the fluorite-type structure

    International Nuclear Information System (INIS)

    Zhang, F.X.; Lang, M.; Wang, J.W.; Li, W.X.; Sun, K.; Prakapenka, V.; Ewing, R.C.

    2014-01-01

    A new high-pressure phase of U 3 O 8 , which has a fluorite-type structure, forms at pressures greater than ∼8.1 GPa that was confirmed by in situ x-ray diffraction (XRD) measurements. The fluorite-type U 3 O 8 is stable at pressures at least up to ∼40 GPa and temperatures to 1700 K, and quenchable to ambient conditions. Based on the XRD analysis, there is a huge volume collapse (>20%) for U 3 O 8 during the phase transition and the quenched high-pressure phase is 28% denser than the initial orthorhombic phase at ambient conditions. The high-pressure phase has a very low compressibility comparing with the starting orthorhombic phase. - Graphical abstract: α-U 3 O 8 is in a layered structure with orthorhombic symmetry, at high pressures, it transformed to a fluorite-type cubic structure. There are a lot of defects in the cubic structure, and it is a new kind of hyperstoichiometric uranium oxide, which is stable at ambient conditions. - Highlights: • A new fluorite-type high-pressure phase was found in hyperstoichometric UO 2 +x (x∼0.8). • The new high-pressure structure is quenchable to ambient conditions. • Pressure driven phase transition in orthorhombic U 3 O 8 was first found

  16. Observations on 3He release from ErT2 films

    International Nuclear Information System (INIS)

    Venhaus, T.J.; Poths, J.

    2004-01-01

    We have loaded thin (500nm) films of erbium to a stoichiometry of ErT 2 , and have been observing their 3 He release characteristics. The films are stored in vacuum-tight metal vessels and the headspace helium is analyzed after accumulation for times ranging from a day to several months. Analysis is performed with very high sensitivity using a static noble gas mass spectrometer. For the first several years, 3 He release is a fairly constant function of helium generation, and does not depend on the substrate or the amount of helium accumulated in the film. We find a somewhat higher helium release (up to 3%) at very early times, decreasing over 6 months to a fairly consistent value (0.8%). This observation is consistent with a bubble nucleation and growth mechanism. The very early release behavior does not appear to be dependent upon the presence or growth of surface oxide layers. We also observed that, despite the very low vapor pressure of ErT 2 , our vacuum system became contaminated with low levels of tritium, representing perhaps a few ppm of the tritium in a sample.

  17. (3He,α) reaction mechanism at high energy and neutron inner shell structure

    International Nuclear Information System (INIS)

    Wiele, J. van de.

    1980-01-01

    The ( 3 He,α) reaction on 12 C, 16 O, 28 Si, 58 Ni, 90 Zr, 118 Sn, 124 Sn and 208 Pb targets has been studied at Esub( 3 He) = 217 MeV (or 205 MeV) in order to investigate the reaction mechanism at high energy and large momentum transfer. The reaction yields large cross sections at very forward angles and strongly enhances the largest orbital momentum transfer. The angular distribution shapes are well reproduced in the frame-work of the Z-R- D.W.B.A. analysis if we use a unique empirical α-potential: Vsub(α)(Esub(α)) = Vsub( 3 He)(3/4 Esub(α)) + Vsub(n)(1/4 Esub(α)). The excitation energy spectra have been measured up to 100 MeV in the residual light and medium nuclei and up to about 16 MeV in heavy nuclei. In addition to the well-known low-lying levels, peaks or broad structures are observed for each nucleus at higher excitation energies. They are attributed to pick up from inner shells: 1s( 11 C and 15 O), 1p( 27 Si), 1d5/2 + 1p( 57 Ni), 1f7/2( 89 Zr) 1g9/2 117 Sn, 123 Sn and 1h11/2( 207 Pb). Selectivity and localization of direct and indirect pick up ( 3 He,α) reactions were studied. Finite range calculations show that this reaction is not very sensitive to the details of the range from function but only to D 0 coefficient and range R. A microscopic α-nucleus optical potential calculated with n-n dependent and independent density forces is able to reproduce both elastic scattering and pick up reaction angular distributions [fr

  18. Extraction of GEN at Q2 = 1 (GeV/c)2 from Measurements of polarized He(pol. e, e')

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Ge [Univ. of Virginia, Charlottesville, VA (United States)

    2011-05-01

    The neutron electric form factor, GEN , is extracted for the first time at Q2 = 1 (GeV/c)2 from polarized 3$\\vec{He}$ ($\\vec{e}$ ,e ') measurements in Hall A at Jefferson Lab. By getting the ratio of asymmetries in longitudinal and transverse quasi-elastic 3$\\vec{He}$($\\vec{e}$,e ' ), the electric and magnetic contributions can be separated. The proton and neutron contributions to the 3 He quasi-elastic response functions are calculated in PWIA by Salme? et al., and the neutron electric form factor can be extracted. This method of inclusive scattering becomes feasible for the first time due to the falloff of the other form factors at high Q2 while G$n\\atop{E}$ keeps increasing in units of the dipole form factor. Approximately, 20% uncertainty is achieved in the extraction largely contributed by the statistical uncertainties from 3 days of data-taking. All aspects of the measurement will be discussed in this thesis including theoretical model, experiment setup and the details in the analysis.

  19. Study of the sup 3 H( sup 3 H, 2n) sup 4 He and sup 3 He( sup 3 He, 2p) sup 4 He reactions in the framework of three-cluster microscopic model

    CERN Document Server

    Vasilevsky, V S; Arickx, F; Broeckhove, J

    2002-01-01

    The reactions sup 3 H( sup 3 H, 2n) sup 4 He and sup 3 He( sup 3 He, 2p) sup 4 He are investigated within a fully microscopic cluster model featuring a three-cluster exit channel. A Hyperspherical Harmonics basis is used to describe the three-cluster continuum. The resulting astrophysical s-factor of both reactions is in good agreement with experimental data. Analysis of the low-energy scattering parameters reveals no evidence for a hidden resonance state would increase the cross-section of the reactions, and would help to resolve the solar neutrino problem.

  20. On the possibility of developing quasi-CW high-power high-pressure laser on 4p-4s transition of ArI with electron beam—optical pumping: quenching of 4s (3P2) lower laser level

    Science.gov (United States)

    Ionin, A. A.; Kholin, I. V.; L'dov, A. Yu; Seleznev, L. V.; Ustinovskii, N. N.; Zayarnyi, D. A.

    2017-12-01

    A new electron beam-optical procedure is proposed for quasi-cw pumping of high-pressure large-volume He-Ar laser on the 4p[1/2]1-4s[3/2]20 argon atom transition at the wavelength of 912.5 nm. It consists of creation and maintenance of a necessary density of the 4s[3/2]20 metastable state in the gain medium by a fast electron beam and subsequent optical pumping of the upper laser level via the classical three-level scheme using a laser diode. Absorption probing is used to study collisional quenching of Ar* metastable in electron-beam-excited high-pressure He-Ar mixtures with a low content of argon. The rate constants for plasma-chemical reactions Ar*  +  He  +  Ar  >  Ar2*   +  He (3.6  ±  0.4)  ×  10-33 cm6 s-1, Ar*  +  2He  >  HeAr*  +  He (4.4  ±  0.9)  ×  10-36 cm6 s-1 and Ar*  +  He  >  Products  +  He (2.4  ±  0.3)  ×  10-15 cm3 s-1 were for the first time measured.

  1. Electrical resistance, superconductivity and phase transformations of Rb and Cs under high pressure

    International Nuclear Information System (INIS)

    Ullrich, K.

    1980-01-01

    Four lead electrical resistance measurements were performed on Rb under pressures up to 210 kbar for temperatures in the range 0.05 K to 300 K. Pressure was applied using a Bridgman-anvil-configuration with dense sintered diamond in the highly stressed tip regions of the Carboloy pistons. The sample cell was pressurized at room temperature by a mechanical press connected to the mixing chamber of a 3 He- 4 He-cryostat. The pressure remained essentially constant during cooling. Discontinuous changes in resistance at pressures of 70 and 140 kbar indicate two phase transitions and confirm the results of other authors. The resistance of Rb increases after a minimum at 20 kbar by about two orders of magnitude. (orig.) [de

  2. Mobility of negative ions in superfluid 3He

    International Nuclear Information System (INIS)

    Ahonen, A.I.; Kokko, J.; Lounasmaa, O.V.; Paalanen, M.A.; Richardson, R.C.; Schoepe, W.; Takano, Y.

    1977-01-01

    The mobility of negative ions is shown to increase rapidly below T/sub c/ in both superfluid 3 He phases. The ratio μ/μ/sub N/ of superfluid to normal mobility is larger in the B phase than in the A phase. A critical velocity consistent in magnitude with the Landau limit for pair breaking has also been observed. In the normal fluid we find a temperature independent mobility between 40 mK and T/sub c/ for all pressures between 0 and 28 bar. The increase of μ/sub N/ with increasing pressure is in agreement with the bubble model for the negative ion

  3. Measurement of the neutron (3He) spin structure functions at low Q2: A connection between the Bjorken and gerasimov-drell-hearn sum rule

    Energy Technology Data Exchange (ETDEWEB)

    Djawotho, Pibero [College of William and Mary, Williamsburg, VA (United States)

    2002-12-01

    This dissertation presents results of experiment E94-010 performed at Jefferson Laboratory (simply known as JLab) in Hall A. The experiment aimed to measure the low Q2 evolution of the Gerasimov-Drell-Hearn (GDH) integral from Q2 = 0.1 to 0.9 GeV2. The GDH sum rule at the real photon point provides an important test of Quantum Chromodynamics (QCD). The low Q2 evolution of the GDH integral contests various resonance models, Chiral Perturbation Theory ({chi} PT) and lattice QCD calculations, but more importantly, it helps us understand the transition between partonic and hadronic degrees of freedom. At high Q2, beyond 1 GeV2, the difference of the GDH integrals for the proton and the neutron is related to the Bjorken sum rule, another fundamental test of QCD. In addition, results of the measurements for the spin structure functions g1 and g2, cross sections, and asymmetries are presented. E94-010 was the first experiment of its kind at JLab. It used a high-pressure, polarized 3He target with a gas pressure of 10 atm and average target polarization of 35%. For the first time, the polarized electron source delivered an average beam polarization of 70% with a beam current of 15 micro A. The limit on the beam current was only imposed by the target. The experiment required six different beam energies from 0.86 to 5.1 GeV. This was the first time the accelerator ever reached 5.1 GeV. Both High-Resolution Spectrometers of Hall A, used in singles mode, were positioned at 15.5 ° each.

  4. Construction and test of a polarized proton target

    International Nuclear Information System (INIS)

    Aures, R.

    1983-12-01

    This work describes experiments in which for the first time a proton target has been constructed which is polarized by the ''brute-force'' method. This method requires very low temperatures and high magnetic fields. The low temperatures (down to 10 mK) are obtained by a 3 He/ 4 He dilution refrigerator, the magnetic field (up to 9 T) is produced by a superconducting split pair magnet. The proton target has a volume of about 18 cm 3 and consists of pressed titaniumhydride powder, which has a titanium/-hydrogen ratio of 1:1,96. The hydrogen content is 1,3 mol. Titaniumhydride has the advantage of sufficient heat conductivity at low temperatures and a very high proton density. The heat conductivity of the sample is measured, with and without the presence of a magnetic field. Thermodynamical measurements and adiabatic demagnetisation experiments proved quantitatively the polarization of the protons. The polarization of the proton has been measured in a transmission experiment using polarized neutrons of 1.2 MeV. The result shows a good agreement of theoretical and actual polarization. From the results it can be concluded, that this sample can be used successfully as a polarized proton target for neutron scattering experiments to measure spin-correlations. (orig.) [de

  5. Thermodynamic study of the A-B phase transition in superfluid 3He: Phase diagram and consequences

    International Nuclear Information System (INIS)

    Hahn, I.

    1993-01-01

    The authors have measured the A-B phase transition temperature of superfluid 3 He at pressures from zero to 29 bars, and in all magnetic fields up to the high field limit of the B phase (0.59 Tesla). This work is the first precision measurement of the A-B phase transition over the entire phase diagram (P, T, B). Measurements at low magnetic fields can be related to microscopic interactions in liquid 3 He. The results show that all current microscopic models of normal liquid 3 He are incomplete. Also, the results suggest the possibility that the conventional identification of the order parameter of superfluid 3 He-A is incorrect. The measurements at high magnetic fields can be related through thermodynamic identities to quantities which are immeasurable directly, such as the molar volume changes at the A-B phase transition, and the specific heat of the A-phase of superfluid 3 He in the limit T → 0. The authors detect the phase transition by monitoring the attenuation of zero around traversing a 4-mm path in the superfluid. Because thermometry is so crucial to the success of the measurements, the authors elected to use two independent thermometers. The authors use a pulsed NMR measurement of the susceptibility of Pt nuclei, which varies as 1/T, to guarantee linearity of the temperature scale. In order to achieve the high resolution required by the experiment, the authors also use an LCMN thermometer driven by a unique digital bridge which the authors constructed

  6. Elastic scattering of polarized protons on helium three at 800 MeV

    International Nuclear Information System (INIS)

    Azizi, A.

    1985-07-01

    A set of spin dependent parameters and cross sections has been measured for polarized p- 3 He elastic scattering over the range of q .7 to 4.2 fm -1 . The experiment was done at the Los Alamos Meson Physics Facility (LAMPF) using the High Resolution Spectrometer (HRS) with a polarized proton beam at .8 GeV. The focal plane polarimeter of the HRS was used to determine the spin direction of the scattered proton. Since 3 He is one of the simplest nuclei, polarized p- 3 He scattering provides a very sensitive test of multiple scattering theories. The theoretical analysis was done by using two different wave functions for 3 He as input to the multiple scattering theory. The theoretical calculations and experimental data together will give us useful information about nucleon-nucleon amplitudes and also help us to obtain a better understanding of the scattering process. 68 refs., 55 figs., 9 tabs

  7. Elastic scattering of polarized protons on helium three at 800 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Azizi, A.

    1985-07-01

    A set of spin dependent parameters and cross sections has been measured for polarized p-/sup 3/He elastic scattering over the range of q .7 to 4.2 fm/sup -1/. The experiment was done at the Los Alamos Meson Physics Facility (LAMPF) using the High Resolution Spectrometer (HRS) with a polarized proton beam at .8 GeV. The focal plane polarimeter of the HRS was used to determine the spin direction of the scattered proton. Since /sup 3/He is one of the simplest nuclei, polarized p-/sup 3/He scattering provides a very sensitive test of multiple scattering theories. The theoretical analysis was done by using two different wave functions for /sup 3/He as input to the multiple scattering theory. The theoretical calculations and experimental data together will give us useful information about nucleon-nucleon amplitudes and also help us to obtain a better understanding of the scattering process. 68 refs., 55 figs., 9 tabs.

  8. Experimental Research of the Radiative Capture of Thermal Neutrons in $^{3}$He

    CERN Document Server

    Bystritsky, V M; Enik, T L; Filipowicz, M; Gerasimov, V V; Grebenyuk, V M; Kobzev, A P; Kublikov, R V; Nesvizhevsky, V V; Parzhitskii, S S; Pavlov, V N; Popov, N P; Salamatin, A V; Shvetsov, V N; Slepnev, V M; Strelkov, A V; Wozniak, J; Zamyatin, N I

    2006-01-01

    A project of an experiment on measurement of the cross sections of radiative thermal neutron capture by $^{3}$He nuclei with production of one and two $\\gamma $-quanta ($n_{\\rm th}+^{3}$He $\\to \\alpha + \\gamma $(2$\\gamma $)) is presented. The interest in studying the processes is dictated by the following factors: a possibility of obtaining information on parameters of the nucleon $N$-$N$ potential and structure of exchange meson currents; a possibility of verifying the model of the mechanism for nucleon capture by the nucleus $^{3}$He in the low-energy region; necessity to solve some questions existing in astrophysics. The experiment is planned to be carried out on the PF1B beam of ILL reactor (Grenoble). The target is a hollow cylinder of pure aluminium ($\\varnothing$140$\\times $80~mm) filled with $^{3}$He and $^{4}$He (background experiment) at the pressure 2~atm. Registration of the $\\gamma $-quanta is carried out by four BGO crystal ($\\varnothing$100$\\times $70~mm) detectors. According to the calculation...

  9. Thermometry in 3He

    International Nuclear Information System (INIS)

    Richardson, R.C.

    1977-01-01

    Some of the methods used in measuring the temperatures of the transitions in 3 He are reviewed. Although noise thermometers, γ-ray anisotropy thermometers and even Pt NMR thermometers are satisfactory for furnishing temperature standards, they are not satisfactory secondary thermometers. The susceptibility of CMN and various 3 He properties make more precise and quicker thermometric indications. (Auth.)

  10. Δ excitation in 3He and 4He by photons

    International Nuclear Information System (INIS)

    Maruyama, Koichi.

    1993-06-01

    The use of the 3 He and 4 He photodisintegration reactions in the study of the excitation, propagation, and decay of the Δ (1232) in these nuclei is proposed. By using the data obtained with TAGX for both photon absorption on neutron-proton pairs and complete photodisintegration, we find no compelling evidence for the change of the Δ property in the 3 He and 4 He nuclei. It is also proposed to use nuclear photodisintegration in the search for the excitation of the higher-mass nucleon resonances whose absence in the total photon-absorption cross sections in nuclei is reported recently. (author)

  11. Single crystal growth, characterization and high-pressure Raman spectroscopy of impurity-free magnesite (MgCO3)

    Science.gov (United States)

    Liang, Wen; Li, Zeming; Yin, Yuan; Li, Rui; Chen, Lin; He, Yu; Dong, Haini; Dai, Lidong; Li, Heping

    2018-05-01

    The understanding of the physical and chemical properties of magnesite (MgCO3) under deep-mantle conditions is highly important to capture the essence of deep-carbon storage in Earth's interior. To develop standard rating scales, the impurity-free magnesite single crystal, paying particular attention to the case of avoiding adverse impacts of Ca2+, Fe2+, and Mn2+ impurities in natural magnesite, is undoubtedly necessary for all research of magnesite, including crystalline structural phase transitions, anisotropic elasticity and conductivity, and equation of state (EoS). Thus, a high-quality single crystal of impurity-free magnesite was grown successfully for the first time using the self-flux method under high pressure-temperature conditions. The size of the magnesite single crystal, observed in a plane-polarized microscope, exceeds 200 μm, and the crystal exhibits a rhombohedral structure to cleave along the (101) plane. In addition, its composition of Mg0.999 ± 0.001CO3 was quantified through electron probing analysis. The structural property was investigated by means of single crystal X-ray diffraction and the unit cell dimensions obtained in the rhombohedral symmetry of the R\\bar {3}c space group are a = 4.6255 (3) and c = 14.987 (2), and the final R = 0.0243 for 718 reflections. High-pressure Raman spectroscopy of the magnesite single crystal was performed up to 27 GPa at ambient temperature. All Raman active bands, ν i, without any splitting increased almost linearly with increasing pressure. In combination with the high-pressure Raman results {{d/ν _i}}{{{d}P}} and the bulk modulus K T (103 GPa) reported from magnesite EoS studies, the mode Grüneisen parameters (1.49, 1.40, 0.26, and 0.27) of each vibration ( T, L, ν 4, and ν 1) were calculated.

  12. Highly polarization sensitive photodetectors based on quasi-1D titanium trisulfide (TiS3)

    Science.gov (United States)

    Liu, Sijie; Xiao, Wenbo; Zhong, Mianzeng; Pan, Longfei; Wang, Xiaoting; Deng, Hui-Xiong; Liu, Jian; Li, Jingbo; Wei, Zhongming

    2018-05-01

    Photodetectors with high polarization sensitivity are in great demand in advanced optical communication. Here, we demonstrate that photodetectors based on titanium trisulfide (TiS3) are extremely sensitive to polarized light (from visible to the infrared), due to its reduced in-plane structural symmetry. By density functional theory calculation, TiS3 has a direct bandgap of 1.13 eV. The highest photoresponsivity reaches 2500 A W-1. What is more, in-plane optical selection caused by strong anisotropy leads to the photoresponsivity ratio for different directions of polarization that can reach 4:1. The angle-dependent photocurrents of TiS3 clearly display strong linear dichroism. Moreover, the Raman peak at 370 cm-1 is also very sensitive to the polarization direction. The theoretical optical absorption of TiS3 is calculated by using the HSE06 hybrid functional method, in qualitative agreement with the observed experimental photoresponsivity.

  13. Development of a liquid {sup 3}He target for experimental studies of antikaon-nucleon interaction at J-PARC

    Energy Technology Data Exchange (ETDEWEB)

    Iio, M., E-mail: masami.iio@kek.jp [RIKEN Nishina Center, RIKEN, Saitama 351-0198 (Japan); High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Ishimoto, S. [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Sato, M. [Department of Physics, The University of Tokyo, Tokyo 113-0033 (Japan); Enomoto, S. [Department of Physics, Osaka University, Osaka 560-0043 (Japan); Hashimoto, T. [Department of Physics, The University of Tokyo, Tokyo 113-0033 (Japan); Suzuki, S. [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Iwasaki, M. [RIKEN Nishina Center, RIKEN, Saitama 351-0198 (Japan); Department of Physics, Tokyo Institute of Technology, Tokyo 152-8551 (Japan); Hayano, R.S. [Department of Physics, The University of Tokyo, Tokyo 113-0033 (Japan)

    2012-09-21

    A liquid {sup 3}He target system was developed for experimental studies of kaonic atoms and kaonic nuclei at J-PARC. {sup 3}He gas is liquefied in a heat exchanger cooled below 3.2 K by decompression of liquid {sup 4}He. To maintain a large acceptance of the cylindrical detector system for decay particles of kaonic nuclei, efficient heat transport between the separate target cell and the main unit is realized using circulation of liquid {sup 3}He. To minimize the amount of material, a vacuum vessel containing a carbon fiber reinforced plastic cylinder having an inside diameter of 150 mm and a thickness of 1 mm was produced. A target cell made of pure beryllium and beryllium-aluminum alloy was developed not only to minimize the amount of material but also to obtain high X-ray transmission. During a cooling test, the target cell was kept at 1.3 K at a pressure of 33 mbar. The total estimated heat load to the components including the target cell and heat exchanger cooled by liquid {sup 4}He decompression, was 0.21 W, and the liquid {sup 4}He consumption rate was 50 L/day.

  14. High-pressure phase transition in Ho2O3

    International Nuclear Information System (INIS)

    Lonappan, Dayana; Shekar, N.V. Chandra; Ravindran, T.R.; Sahu, P. Ch.

    2010-01-01

    High-pressure X-ray diffraction and Raman studies on holmium sesquioxide (Ho 2 O 3 ) have been carried out up to a pressure of ∼17 GPa in a diamond-anvil cell at room temperature. Holmium oxide, which has a cubic or bixbyite structure under ambient conditions, undergoes an irreversible structural phase transition at around 9.5 GPa. The high-pressure phase has been identified to be low symmetry monoclinic type. The two phases coexist to up to about 16 GPa, above which the parent phase disappears. The high-pressure laser-Raman studies have revealed that the prominent Raman band ∼370 cm -1 disappears around the similar transition pressure. The bulk modulus of the parent phase is reported.

  15. High-pressure powder x-ray diffraction experiments on Zn at low temperature

    CERN Document Server

    Takemura, K; Fujihisa, H; Kikegawa, T

    2002-01-01

    High-pressure powder x-ray diffraction experiments have been performed on Zn with a He-pressure medium at low temperature. When the sample was compressed in the He medium at low temperature, large nonhydrostaticity developed, yielding erroneous lattice parameters. On the other hand, when the pressure was changed at high temperatures, good hydrostaticity was maintained. No anomaly in the volume dependence of the c/a axial ratio has been found.

  16. A validation of the 3H/3He method for determining groundwater recharge

    Science.gov (United States)

    Solomon, D. K.; Schiff, S. L.; Poreda, R. J.; Clarke, W. B.

    1993-09-01

    Tritium and He isotopes have been measured at a site where groundwater flow is nearly vertical for a travel time of 100 years and where recharge rates are spatially variable. Because the mid-1960s 3H peak (arising from aboveground testing of thermonuclear devices) is well-defined, the vertical groundwater velocity is known with unusual accuracy at this site. Utilizing 3H and its stable daughter 3He to determine groundwater ages, we compute a recharge rate of 0.16 m/yr, which agrees to within about 5% of the value based on the depth of the 3H peak (measured both in 1986 and 1991) and two-dimensional modeling in an area of high recharge. Zero 3H/3He age occurs at a depth that is approximately equal to the average depth of the annual low water table, even though the capillary fringe extends to land surface during most of the year at the study site. In an area of low recharge (0.05 m/yr) where the 3H peak (and hence the vertical velocity) is also well-defined, the 3H/3He results could not be used to compute recharge because samples were not collected sufficiently far above the 3H peak; however, modeling indicates that the 3H/3He age gradient near the water table is an accurate measure of vertical velocities in the low-recharge area. Because 3H and 3He have different diffusion coefficients, and because the amount of mechanical mixing is different in the area of high recharge than in the low-recharge area, we have separated the dispersive effects of mechanical mixing from molecular diffusion. We estimate a longitudinal dispersivity of 0.07 m and effective diffusion coefficients for 3H (3HHO) and 3He of 2.4×10-5 and 1.3×10-4 m2/day, respectively. Although the 3H/3He age gradient is an excellent indicator of vertical groundwater velocities above the mid-1960s 3H peak, dispersive mixing and diffusive loss of 3He perturb the age gradient near and below the 3H peak.

  17. Effect of Gas Pressure on Polarization of SOFC Cathode Prepared by Plasma Spray

    Science.gov (United States)

    Li, Cheng-Xin; Wang, Zhun-Zhun; Liu, Shuai; Li, Chang-Jiu

    2013-06-01

    A cermet-supported tubular SOFC was fabricated using thermal spray. The cell performance was investigated at temperatures from 750 to 900 °C and pressures from 0.1 to 0.5 MPa to examine the effect of operating gas pressure on the cell performance. The influence of gas pressure on the cathodic polarization was studied through the electrochemical impedance approach to examine the controlling electrochemical processes during cell operation. Results show that increasing the operating gas pressure improves the power output performance significantly. When the gas pressure is increased from 0.1 to 0.3 MPa, the maximum power density is increased by a factor of 32% at a temperature of 800 °C. The cathode polarization decreases significantly with the increase of the gas pressure. The electrochemical analysis shows that the main control processes of the cathode reaction are the oxygen species transfer at the three-phase boundary and oxygen diffusion on the surface or in the bulk of the cathode, which are enhanced with increasing gas pressure.

  18. Analysis of the collagen birefringence and the relative attenuation coefficient of health and burned skin irradiated with linearly polarized He-Ne laser

    International Nuclear Information System (INIS)

    Silva, Daniela de Fatima Teixeira da

    2002-01-01

    Low-intensity laser therapy is characterized by its ability to induce athermic effects and nondestructive photobiological processes. Although it has been in use for more than 40 years, this phototherapy is still not an established therapeutic modality. The objectives of this study were: to quantify the collagen fibers organization by polarized light microscopy in normal and burned skin samples at day 17 post-injury considering preferential axis as the animal's spinal column and aligning the linear laser polarization in two directions of polarization, parallel or perpendicular to this axis; to determine the relative attenuation coefficient for the intensity light by the technique of imaging the light distribution in normal and burned skin during wound healing process taking only parallel direction of polarization. To reach the objectives, burns about 6 mm in diameter were created with liquid N 2 on the back of the rats and the lesions were irradiated on days 3, 7, 10 and 14 post-wounding, D= 1 J/cm 2 , to investigate the effects of low-intensity linearly polarized He-Ne laser beam on skin wounds healing. Control lesions were not irradiated. The results have demonstrated that: the skin samples irradiated with linearly parallel polarized He-Ne laser beam showed collagen fibers more organized; burned skin samples presents a higher attenuation coefficient than normal skin samples. These results are important to optimize low intensity laser therapy dosimetry on acceleration wound healing. (author)

  19. The analysis of energy efficiency in water electrolysis under high temperature and high pressure

    Science.gov (United States)

    Hourng, L. W.; Tsai, T. T.; Lin, M. Y.

    2017-11-01

    This paper aims to analyze the energy efficiency of water electrolysis under high pressure and high temperature conditions. The effects of temperature and pressure on four different kinds of reaction mechanisms, namely, reversible voltage, activation polarization, ohmic polarization, and concentration polarization, are investigated in details. Results show that the ohmic and concentration over-potentials are increased as temperature is increased, however, the reversible and activation over-potentials are decreased as temperature is increased. Therefore, the net efficiency is enhanced as temperature is increased. The efficiency of water electrolysis at 350°C/100 bars is increased about 17%, compared with that at 80°C/1bar.

  20. Polarized proton target-IV. Operations manual

    International Nuclear Information System (INIS)

    Hill, D.; Fletcher, O.; Moretti, A.; Onesto, F.

    1976-01-01

    Standard operating procedures are presented for the vacuum, cryogenic, and electronic systems of a polarized proton target. The systems are comprised of (1) a target cryostat; (2) a 4 He pumping system; (3) a 3 He pumping system; (4) a microwave system; (5) a magnet and power supply; (6) a computerized polarization monitor; and (7) miscellaneous auxiliary equipment

  1. Studies Of Submicron 3He Slabs Using A High Precision Torsional Oscillator

    International Nuclear Information System (INIS)

    Corcoles, Antonio; Casey, Andrew; Cowan, Brian; Saunders, John; Parpia, Jeevak; Bowley, Roger

    2006-01-01

    A high precision torsional oscillator has been used to study 3He films of thickness in the range 100 to 350 nm. In previous work we found that the films decoupled from the oscillator motion below 60 mK, in the Knudsen limit. This precluded observation of the superfluid transition. Here we report measurements using a torsional oscillator whose highly polished inner surfaces have been decorated with a low density of silver particles to act as random elastic scattering centres. This modification locks the normal film to the surface. A superfluid transition of the film is observed

  2. Temporal evolution of atmosphere pressure plasma jets driven by microsecond pulses with positive and negative polarities

    Science.gov (United States)

    Shao, Tao; Yang, Wenjin; Zhang, Cheng; Fang, Zhi; Zhou, Yixiao; Schamiloglu, Edl

    2014-09-01

    Current-voltage characteristics, discharge images, and optical spectra of atmospheric pressure plasma jets (APPJs) are studied using a microsecond pulse length generator producing repetitive output pulses with different polarities. The experimental results show that the APPJs excited by the pulses with positive polarity have longer plume, faster propagation speed, higher power, and more excited species, such as \\text{N}2 , O, He, \\text{N}2+ , than that with the negatively excited APPJs. The images taken using an intensified charge-coupled device show that the APPJs excited by pulses with positive polarity are characterized by a bullet-like structure, while the APPJs excited by pulses with negative polarity are continuous. The propagation speed of the APPJs driven by a microsecond pulse length generator is about tens of km/s, which is similar to the APPJs driven by a kHz frequency sinusoidal voltage source. The analysis shows that the space charge accumulation effect plays an important role during the discharge. The transient enhanced electric field induced by the accumulated ions between the needle-like electrode and the nozzle in the APPJs excited by pulses with negative polarity enhances electron field emission from the cathode, which is illustrated by the bright line on the time-integrated images. This makes the shape of the APPJ excited using pulses with negative polarity different from the bullet-like shape of the APPJs excited by pulses with positive polarity.

  3. Stabilization of He2(A(sup 3)Sigma(sub u)(+)) molecules in liquid helium by optical pumping for vacuum UV laser

    Science.gov (United States)

    Zmuidzinas, J. S. (Inventor)

    1978-01-01

    A technique is disclosed for achieving large populations of metastable spin-aligned He2(a 3 Sigma u +) molecules in superfluid helium to obtain lasing in the vacuum ultraviolet wavelength regime around 0.0800 micron m by electronically exciting liquid (superfluid) helium with a comparatively low-current electron beam and spin aligning the metastable molecules by means of optical pumping with a modestly-powered (100mW) circularly-polarized continuous wave laser operating at, for example, 0.9096 or 0.4650 micron m. Once a high concentration of spin-aligned He2 (a 3 Sigma u +) is achieved with lifetimes of a few milliseconds, a strong microwave signal destroys the spin alignment and induces a quick collisional transition of He2 (a 3 Sigma u +) molecules to the a 1 Sigma u + state and thereby a lasing transition to the X 1 Sigma g + state.

  4. Lowest vibrational states of 4He3He+: Non-Born-Oppenheimer calculations

    International Nuclear Information System (INIS)

    Stanke, Monika; Bubin, Sergiy; Kedziera, Dariusz; Molski, Marcin; Adamowicz, Ludwik

    2007-01-01

    Very accurate quantum mechanical calculations of the first five vibrational states of the 4 He 3 He + molecular ion are reported. The calculations have been performed explicitly including the coupling of the electronic and nuclear motions [i.e., without assuming the Born-Oppenheimer (BO) approximation]. The nonrelativistic non-BO wave functions were used to calculate the α 2 relativistic mass velocity, Darwin, and spin-spin interaction corrections. For the lowest vibrational transition, whose experimental energy is established with high precision, the calculated and the experimental results differ by only 0.16 cm -1

  5. Lattice dynamics of fcc helium at high pressure

    International Nuclear Information System (INIS)

    Eckert, J.; Thomlinson, W.; Shirane, G.

    1977-01-01

    The neutron-inelastic-scattering technique was used to measure the phonon dispersion relations in a high-density crystal of fcc He at 38 K. The crystal was grown at a pressure of 4.93 kbar and a temperature of 38.5 K in a high-pressure sample holder. Its lattice parameter was determined to be 3.915 +- 0.002 A, equivalent to a molar volume of 9.03 cm 3 /mol. The measured dispersion curves were found to be in good agreement with a recent calculation by Goldman using the first-order self-consistent phonon theory without short-range correlation functions. The strong anharmonic effects observed in earlier measurements on the crystals of 21 cm 3 /mol were found to be much less prominent in this He crystal. The magnitude of the multiphonon interference effects on the one-phonon intensities is shown to be less than half of that observed in the low-density crystals. Thermodynamic analysis of the data yielded THETA/sup M//sub D/ = 154 K which indicates that the ratio of mean amplitude of vibration to the nearest-neighbor distance is 8.6%, as opposed to nearly 30% for the lowest-density He crystals. The dependence of the phonon energies on volume is discussed with reference to the earlier work of Traylor et al. on an fcc crystal at 11.7 cm 3 /mol. Limited measurements were also made at 22 K to determine the temperature dependence of the phonon energies. Unusually large isochoric temperature shifts of as much as 15% for some phonons close to the zone center were found over the range of 22--38 K

  6. Dynamic Nuclear Polarization at low temperature and high magnetic eld for biomedical applications in Magnetic Resonance Spectroscopic Imaging

    International Nuclear Information System (INIS)

    Goutailler, Florent

    2011-01-01

    The aim of this thesis work was to design, build and optimize a large volume multi-samples DNP (Dynamic Nuclear Polarization) polarizer dedicated to Magnetic Resonance Spectroscopic Imaging applications. The experimental system is made up of a high magnetic field magnet (3,35 T) in which takes place a cryogenic system with a pumped bath of liquid helium ("4He) allowing temperatures lower than 1,2 K. A set of inserts is used for the different steps of DNP: irradiation of the sample by a microwave field (f=94 GHz and P=50 mW), polarization measurement by Nuclear Magnetic Resonance... With this system, up to three samples of 1 mL volume can be polarized to a rate of few per-cents. The system has a long autonomy of four hours, so it can be used for polarizing molecules with a long time constant of polarization. Finally, the possibility to get quasi-simultaneously, after dissolution, several samples with a high rate of polarization opens the way of new applications in biomedical imaging. (author) [fr

  7. Regional and temporal variations in CO2/3He, 3He/4He and δ13C along the North Anatolian Fault Zone, Turkey

    International Nuclear Information System (INIS)

    Leeuw, G.A.M. de; Hilton, D.R.; Guelec, N.; Mutlu, H.

    2010-01-01

    New He and C relative abundance, isotope and concentration results from nine geothermal locations situated along an 800-km transect of the North Anatolian Fault Zone (NAFZ), Turkey, that were monitored during the period November 2001-November 2004, are reported. The geothermal waters were collected every 3-6 months to study possible links between temporal geochemical variations and seismic activity along the NAFZ. At the nine sample locations, the He isotope ratios range from 0.24 to 2.3R A , δ 13 C values range from -4.5 to +5.8 per mille, and CO 2 / 3 He ratios range from 5 x 10 9 to 5 x 10 14 . The following geochemical observations are noted: (1) the highest 3 He/ 4 He ratios are found near the Galatean volcanic region, in the central section of the NAFZ, (2) at each of the nine sample locations, the 3 He/ 4 He ratios are generally constant; however, CO 2 / 3 He ratios and He contents both show one order of magnitude variability, and δ 13 C values show up to ∼4 per mille variability, and (3) at all locations (except Resadiye), δ 13 C values show positive correlations with CO 2 contents. The results indicate that at least three processes are necessary to account for the geochemical variations: (1) binary mixing between crustal and mantle-derived volatiles can explain the general characteristics of 3 He/ 4 He ratios, δ 13 C values, and CO 2 / 3 He ratios at the nine sample locations; (2) preferential degassing of He from the geothermal waters is responsible for variations in CO 2 / 3 He values and He contents at each sample location; and (3) CO 2 dissolution followed by calcite precipitation is responsible for variations in CO 2 contents and δ 13 C values at most locations. For each of the geochemical parameters, anomalies are defined in the temporal record by values that fall outside two standard deviations of average values at each specific location. Geochemical anomalies that may be related to seismic activity are recorded on June 28, 2004 at Yalova

  8. Generating highly polarized nuclear spins in solution using dynamic nuclear polarization

    DEFF Research Database (Denmark)

    Wolber, J.; Ellner, F.; Fridlund, B.

    2004-01-01

    A method to generate strongly polarized nuclear spins in solution has been developed, using Dynamic Nuclear Polarization (DNP) at a temperature of 1.2K, and at a field of 3.354T, corresponding to an electron spin resonance frequency of 94GHz. Trityl radicals are used to directly polarize 13C...... and other low-γ nuclei. Subsequent to the DNP process, the solid sample is dissolved rapidly with a warm solvent to create a solution of molecules with highly polarized nuclear spins. Two main applications are proposed: high-resolution liquid state NMR with enhanced sensitivity, and the use...

  9. Oxygen-sensitive 3He-MRI in bronchiolitis obliterans after lung transplantation

    International Nuclear Information System (INIS)

    Gast, Klaus K.; Biedermann, Alexander; Herweling, Annette; Schreiber, Wolfgang G.; Schmiedeskamp, Joerg; Mayer, Eckhard; Heussel, Claus P.; Markstaller, Klaus; Eberle, Balthasar; Kauczor, Hans-Ulrich

    2008-01-01

    Oxygen-sensitive 3 He-MRI was studied for the detection of differences in intrapulmonary oxygen partial pressure (pO 2 ) between patients with normal lung transplants and those with bronchiolitis obliterans syndrome (BOS). Using software developed in-house, oxygen-sensitive 3 He-MRI datasets from patients with normal lung grafts (n = 8) and with BOS (n = 6) were evaluated quantitatively. Datasets were acquired on a 1.5-T system using a spoiled gradient echo pulse sequence. Underlying diseases were pulmonary emphysema (n 10 datasets) and fibrosis (n = 4). BOS status was verified by pulmonary function tests. Additionally, 3 He-MRI was assessed blindedly for ventilation defects. Median intrapulmonary pO 2 in patients with normal lung grafts was 146 mbar compared with 108 mbar in patients with BOS. Homogeneity of pO2 distribution was greater in normal grafts (standard deviation pO2 34 versus 43 mbar). Median oxygen decrease rate during breath hold was higher in unaffected patients (-1.75 mbar/s versus -0.38 mbar/s). Normal grafts showed fewer ventilation defects (5% versus 28%, medians). Oxygen-sensitive 3 He-MRI appears capable of demonstrating differences of intrapulmonary pO2 between normal lung grafts and grafts affected by BOS. Oxygen-sensitive 3 He-MRI may add helpful regional information to other diagnostic techniques for the assessment and follow-up of lung transplant recipients. (orig.)

  10. The construction of a Pomeranchuk cell driven by a 4He-circulating dilution refrigerator and some related experiments

    International Nuclear Information System (INIS)

    Brandt, B. van den.

    1981-01-01

    This thesis deals with some investigations at very low temperatures in which a 4 He-circulating 3 He- 4 He dilution refrigerator and a Pomeranchuk cooling device are used. The main theme is the design and construction of a special device, a Pomeranchuk cell that is precooled and pressurized with a 4 He-circulating 3 He- 4 He dilution refrigerator, that can be used to obtain a lowest temperature of the order of 1.1 mK. Furthermore, some details of the working of such a dilution refrigerator and some properties of 3 He- 4 He mixtures at high pressures were investigated. (Auth.)

  11. Polarized targets at triangle universities nuclear laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Seely, M.L. [North Carolina State Univ., Raleigh, NC (United States); Gould, C.R. [North Carolina State Univ., Raleigh, NC (United States); Haase, D.G. [North Carolina State Univ., Raleigh, NC (United States); Huffman, P.R. [Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Keith, C.D. [North Carolina State Univ., Raleigh, NC (United States); Roberson, N.R. [Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Tornow, W. [Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Wilburn, W.S. [Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States)

    1995-03-01

    A summary of the polarized and aligned nuclear targets which have been constructed and used at the Triangle Universities Nuclear Laboratory is given. Statically polarized targets, typically operating at a temperature of 12 mK and a magnetic field of 7 T, have provided significant nuclear polarization in {sup 1}H, {sup 3}He, {sup 27}Al, {sup 93}Nb and {sup 165}Ho. A rotating, aligned {sup 165}Ho target is also in use. A {sup 3}He melting curve thermometer has been developed for use in statically polarized targets. A dynamically polarized proton target is under construction. ((orig.))

  12. Mobility of ions trapped on vortex lines in pure 4He and 3He--4He solutions

    International Nuclear Information System (INIS)

    Ostermeier, R.M.; Glaberson, W.I.

    1976-01-01

    Measurements have been made of the mobility of positive and negative ions trapped on vortex lines in pure 4 He and dilute 3 He-- 4 He solutions over the temperature range 1.6 greater than T greater than 0.3 K. In pure 4 He below about 0.7 K, several new effects not seen at higher temperatures are observed and are not easily explained with existing theories. Most notable are an enhanced broadening of the ion pulse and a rapid increase in the mobility with decreasing temperature. Measurements of the electric field dependence of the drift velocity in pure 4 He at low temperatures show a limiting velocity for sufficiently large fields. This behavior can be explained using a simple resonance theory. The inverse mobility data for solutions show sharp increases at certain critical temperatures, which are interpreted as being associated with the condensation of 3 He atoms onto the vortex cores. The dependence of the critical temperature on the bulk 3 He concentration is found to be in good agreement with a simple condensation theory. An extension of arguments used in this theory to lower temperatures leads to the picture of a 3 He-rich core growing with decreasing temperature, consistent with our lower temperature experimental data

  13. Time-reversal asymmetry: polarization and analyzing power in nuclear reactions

    International Nuclear Information System (INIS)

    Rioux, C.; Roy, R.; Slobodrian, R.J.; Conzett, H.E.

    1984-01-01

    Measurements of the proton polarization in the reactions 7 Li( 3 He, p vector) 9 Be and 9 Be( 3 He, p vector) 11 B and of the analyzing powers in the inverse reactions, initiated by polarized protons at the same center-of-mass energies, show significant differences. This implies the failure of the polarization-analyzing-power theorem and, prima facie, of time-reversal invariance in these reactions. The reaction 2 H( 3 He, p vector) 4 He and its inverse have also been investigated and show smaller differences. A discussion of instrumental asymmetries is presented

  14. Time asymmetry: Polarization and analyzing power in the nuclear reactions

    International Nuclear Information System (INIS)

    Rioux, C.; Roy, R.; Slobodrian, R.J.; Conzett, H.E.

    1983-01-01

    Measurements of the proton polarization in the reactions 7 Li( 3 He, p vector) 9 Be and 9 Be( 3 He, p vector) 11 B and of the analyzing powers of the inverse reactions, initiated by polarized protons at the same c.m. energies, show significant differences which imply the failure of the polarization-analyzing-power theorem and, prima facie, of time-reversal invariance in these reactions. The reaction 2 H( 3 He, p vector) 4 He and its inverse have also been investigated and show some smaller differences. A discussion of the instrumental asymmetries is presented. (orig.)

  15. Workshop on polarized neutron filters and polarized pulsed neutron experiments

    International Nuclear Information System (INIS)

    Itoh, Shinichi

    2004-07-01

    The workshop was held in KEK by thirty-three participants on April 26, 2004. The polarized neutron filter method was only discussed. It consists of three parts; the first part was discussed on the polarized neutron methods, the second part on the polarized neutron experiments and the third on the pulse neutron spectrometer and polarized neutron experiments. The six papers were presented such as the polarized 3 He neutron spin filter, neutron polarization by proton polarized filter, soft master and neutron scattering, polarized neutron in solid physics, polarization experiments by chopper spectroscope and neutron polarization system in superHRPD. (S.Y.)

  16. High-momentum components in 3He(e,e') and (e,e'p)

    International Nuclear Information System (INIS)

    Sick, I.

    1984-01-01

    In this talk, the author discusses the properties of the 3 He spectral function S(K,E) at large momentum K and large separation energy E. He deals in particular with the question how to measure S, and how to understand the physics connected to it. As experimental input he uses (e,e') data. He starts by discussing how to understand (e,e') in terms of properties of S(K,E). For this purpose, an extensive discussion of the scaling function F(y) is needed. When once it is found out how to exploit inclusive scattering, he comes back to exclusive reactions and discusses the relative merits of (e,e'p) and (e,e') in order to investigate how these tools can best complement each other. Some conclusions on the properties of S(K,E) at large K and E, together with some suggestions for future activities follows. (Auth.)

  17. Surface damages of polycrystalline W and La2O3-doped W induced by high-flux He plasma irradiation

    Science.gov (United States)

    Liu, Lu; Li, Shouzhe; Liu, Dongping; Benstetter, Günther; Zhang, Yang; Hong, Yi; Fan, Hongyu; Ni, Weiyuan; Yang, Qi; Wu, Yunfeng; Bi, Zhenhua

    2018-04-01

    In this study, polycrystalline tungsten (W) and three oxide dispersed strengthened W with 0.1 vol %, 1.0 vol % and 5.0 vol % lanthanum trioxide (La2O3) were irradiated with low-energy (200 eV) and high-flux (5.8 × 1021 or 1.4 × 1022 ions/m2ṡs) He+ ions at elevated temperature. After He+ irradiation at a fluence of 3.0 × 1025/m2, their surface damages were observed by scanning electron microscopy, energy dispersive spectroscopy, scanning electron microscopy-electron backscatter diffraction, and conductive atomic force microscopy. Micron-sized holes were formed on the surface of W alloys after He+ irradiation at 1100 K. Analysis shows that the La2O3 grains doped in W were sputtered preferentially by the high-flux He+ ions when compared with the W grains. For irradiation at 1550 K, W nano-fuzz was formed at the surfaces of both polycrystalline W and La2O3-doped W. The thickness of the fuzz layers formed at the surface of La2O3-doped W is 40% lower than the one of polycrystalline W. The presence of La2O3 could suppress the diffusion and coalescence of He atoms inside W, which plays an important role in the growth of nanostructures fuzz.

  18. Helicity dependence of the γ 3He → πX reactions in the Δ(1232) resonance region

    International Nuclear Information System (INIS)

    Costanza, S.; Rigamonti, F.; Mushkarenkov, A.; Braghieri, A.; Pedroni, P.; Romaniuk, M.; Mandaglio, G.; Aguar Bartolome, P.; Ahrens, J.; Arends, H.J.; Heid, E.; Jahn, O.; Kashevarov, V.L.; Ostrick, M.; Ortega, H.; Otte, P.B.; Oussena, B.; Schumann, S.; Thomas, A.; Unverzagt, M.; Annand, J.R.M.; Hamilton, D.; Howdle, D.; Livingston, K.; MacGregor, I.J.D.; Mancell, J.; McGeorge, J.C.; Rosner, G.; Beck, R.; Bekrenev, V.; Kruglov, S.; Kulbardis, A.; Berghaeuser, H.; Drexler, P.; Metag, V.; Thiel, M.; Briscoe, W.J.; Downie, E.J.; Cherepnya, S.N.; Fil'kov, L.V.; Lisin, V.; Polonski, A.; Collicott, C.; Fix, A.; Glazier, D.I.; Heil, W.; Krimmer, J.; Hornidge, D.; Middleton, D.G.; Jaegle, I.; Keshelashvili, I.; Krusche, B.; Oberle, M.; Pheron, F.; Rostomyan, T.; Werthmueller, D.; Huber, G.M.; Jude, T.; Watts, D.P.; Kondratiev, R.; Korolija, M.; Supek, I.; Manley, D.M.; Nefkens, B.M.K.; Starostin, A.; Nikolaev, A.; Prakhov, S.; Sarty, A.J.

    2014-01-01

    The helicity dependences of the differential cross sections for the semi-inclusive γ 3 He → π 0 X and γ 3 He → π ± X reactions have been measured for the first time in the energy region 200 γ 450 MeV. The experiment was performed at the tagged photon beam facility of the MAMI accelerator in Mainz using a longitudinally polarised high-pressure 3 He gas target. Hadronic products were measured with the large-acceptance Crystal Ball detector complemented with additional devices for charged-particle tracking and identification. Unpolarised differential cross sections and their helicity dependence are compared with theoretical calculations using the Fix-Arenhoevel model. The effect of the intermediate excitation of the Δ(1232) resonance can be clearly seen from this comparison, especially for the polarised case, where nuclear effects are relatively small. The model provides a better theoretical description of the unpolarised charged pion photoproduction data than the neutral pion channel. It does significantly better in describing the helicity-dependent data in both channels. These comparisons provide new information on the mechanisms involved in pion photoproduction on 3 He and suggest that a polarised 3 He target can provide valuable information on the corresponding polarised quasi-free neutron reactions. (orig.)

  19. Development of a cryogenic source of polarized deuterons ''Polaris''

    International Nuclear Information System (INIS)

    Anishchenko, N.G.; Belushkina, A.A.; Ershov, V.P.

    1985-01-01

    To obtain a beam of polarized deuterons, a cryogenic source ''Polaris'' has been developed according to the program of research at the Dubna synchrophasotron. The source is installed on a high-voltage terminal of the linac preaccelerator. A beam of deuterons from the source is accelerated in the synchrophasotron. At present the source is being improved. A polarimeter with 3 He and 4 He targets has been developed to measure the polarization of the beam of deuterons after the linac. Results of this work are presented in the report

  20. Condensed matter at high shock pressures

    International Nuclear Information System (INIS)

    Nellis, W.J.; Holmes, N.C.; Mitchell, A.C.; Radousky, H.B.; Hamilton, D.

    1985-01-01

    Experimental techniques are described for shock waves in liquids: Hugoniot equation-of-state, shock temperature and emission spectroscopy, electrical conductivity, and Raman spectroscopy. Experimental data are reviewed and presented in terms of phenomena that occur at high densities and temperatures in shocked He, Ar, N 2 , CO, SiO 2 -aerogel, H 2 O, and C 6 H 6 . The superconducting properties of Nb metal shocked to 100 GPa (1 Mbar) and recovered intact are discussed in terms of prospects for synthesizing novel, metastable materials. Ultrahigh pressure data for Cu is reviewed in the range 0.3 to 6TPa (3 to 60 Mbar). 56 refs., 9 figs., 1 tab

  1. He I D3 OBSERVATIONS OF THE 1984 MAY 22 M6.3 SOLAR FLARE

    Energy Technology Data Exchange (ETDEWEB)

    Liu Chang; Xu Yan; Deng Na; Lee, Jeongwoo; Zhang Jifeng; Wang Haimin [Space Weather Research Laboratory, Center for Solar-Terrestrial Research, New Jersey Institute of Technology, University Heights, Newark, NJ 07102-1982 (United States); Prasad Choudhary, Debi, E-mail: chang.liu@njit.edu [Physics and Astronomy Department, California State University Northridge, 18111 Nordhoff Street, Northridge, CA 91330-0001 (United States)

    2013-09-01

    The He I D3 line has a unique response to a flare impact on the low solar atmosphere and can be a powerful diagnostic tool for energy transport processes. Using images obtained from the recently digitized films of the Big Bear Solar Observatory, we report D3 observations of the M6.3 flare on 1984 May 22, which occurred in an active region with a circular magnetic polarity inversion line (PIL). The impulsive phase of the flare starts with a main elongated source that darkens in D3, inside of which bright emission kernels appear at the time of the initial small peak in hard X-rays (HXRs). These flare cores subsequently evolve into a sharp emission strand lying within the dark halo; this evolution occurs at the same time as the main peak in HXRs, reversing the overall source contrast from -5% to 5%. The radiated energy in D3 during the main peak is estimated to be about 10{sup 30} erg, which is comparable to that carried by nonthermal electrons above 20 keV. Afterward, the flare proceeds along the circular PIL in the counterclockwise direction to form a dark circular ribbon in D3, which apparently mirrors the bright ribbons in H{alpha} and He I 10830 A. All of these ribbons last for over one hour in the late gradual phase. We suggest that the present event resembles the so-called black-light flare that was proposed based on continuum images, and that D3 darkening and brightening features herein may be due to thermal conduction heating and the direct precipitation of high-energy electrons, respectively.

  2. High-pressure behavior of methylammonium lead iodide (MAPbI_3) hybrid perovskite

    International Nuclear Information System (INIS)

    Capitani, Francesco; Marini, Carlo; Caramazza, Simone; Postorino, Paolo; Garbarino, Gaston; Hanfland, Michael; Pisanu, Ambra; Quadrelli, Paolo; Malavasi, Lorenzo

    2016-01-01

    In this paper we provide an accurate high-pressure structural and optical study of the MAPbI_3 hybrid perovskite. Structural data show the presence of a phase transition toward an orthorhombic structure around 0.3 GPa followed by full amorphization of the system above 3 GPa. After releasing the pressure, the system keeps the high-pressure orthorhombic phase. The occurrence of these structural transitions is further confirmed by pressure induced variations of the photoluminescence signal at high pressure. These variations clearly indicate that the bandgap value and the electronic structure of MAPI change across the phase transition.

  3. High-pressure behavior of methylammonium lead iodide (MAPbI3) hybrid perovskite

    Science.gov (United States)

    Capitani, Francesco; Marini, Carlo; Caramazza, Simone; Postorino, Paolo; Garbarino, Gaston; Hanfland, Michael; Pisanu, Ambra; Quadrelli, Paolo; Malavasi, Lorenzo

    2016-05-01

    In this paper we provide an accurate high-pressure structural and optical study of the MAPbI3 hybrid perovskite. Structural data show the presence of a phase transition toward an orthorhombic structure around 0.3 GPa followed by full amorphization of the system above 3 GPa. After releasing the pressure, the system keeps the high-pressure orthorhombic phase. The occurrence of these structural transitions is further confirmed by pressure induced variations of the photoluminescence signal at high pressure. These variations clearly indicate that the bandgap value and the electronic structure of MAPI change across the phase transition.

  4. Effects of Δ-isobar degrees of freedom on the reactions 3He(n,γ)4He and 3He(p,e+νe)4He at low-energy

    International Nuclear Information System (INIS)

    Schiavilla, R.

    1991-01-01

    The cross sections of the radiative 3 He(n,γ) 4 He and weak 3 He(p,e + ν e ) 4 He capture reactions at thermal neutron and keV proton energies have been calculated with the Variational Monte Carlo method. The ground state and low-energy continuum wave functions have been determined variationally from a realistic Hamiltonian, and include both nucleon and Δ-isobar degrees of freedom. The electroweak transition operator contains one- and two-body components in the N + Δ Hilbert space

  5. Superconductivity at high pressure in NbSe3

    International Nuclear Information System (INIS)

    Nunez Regueiro, M.; Castello, D.; Mignot, J.M.

    1992-01-01

    We have measured the electrical resistivity of NbSe 3 between 2 K and room temperature up to a pressure of 7.2 GPa. At P 1 = 3.5 GPa we observe the extinction of the high-temperature charge density wave (T 1 -CDW) and the enhancement of the superconducting critical temperature T c to ≅ 5 K. The logarithmic pressure slopes of T 1 (P 1 ) and T c (P > P 1 ) are found to be practically equal. A similar behaviour had been reported previously at lower pressures for T 2 (P 2 ) and T c (P 2 1 ) in the distorted state. We discuss these results in terms of an anisotropic superconducting state in NbSe 3 , with different gaps associated with different types of chains. 10 refs., 2 figs

  6. Development of an optical time-resolved measurement system under high-pressure and low-temperature with a piston-cylinder pressure cell

    Science.gov (United States)

    Tsuchiya, Satoshi; Kino, Yohei; Nakagawa, Koichi; Nakagawa, Daisuke; Yamada, Jun-ichi; Toda, Yasunori

    2016-04-01

    To perform the femtosecond pump-probe spectroscopy under high pressure and low temperature, we constructed a measurement system with a piston cylinder type pressure cell installing an optical fiber bundle. The applied pressure was achieved to 6 kbar and the cell was cooled down to 15 K. Several demonstrations revealed that broadening and change of polarization of pulse (duration of ˜120 fs) owing to the dispersions in the fiber bundle are much small indicating that those have little influence on the measurement of carrier relaxation dynamics. In the measurements of κ-(BEDT-TTF)2Cu(NCS)2 under 1.3 kbar at 43 K, we have successfully detected the polarization anisotropy of the carrier relaxation dynamics and estimated the decay time in the same way as the normal measurement.

  7. High pressure Moessbauer spectroscopy with nuclear resonant forward scattering of synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Nasu, Saburo [Osaka Univ., Toyonaka (Japan). Faculty of Engineering Science

    1996-04-01

    The first observation of the pressure-induced transition from the antiferromagnetic to the ferromagnetic SrFeO{sub 3} was succeeded by measuring Moessbauer spectroscopy under high pressure produced by the diamond anvil cell (DAC). Sample is a polycrystal powder of antiferromagnetic SrFe0{sub 3} with the Neel temperature T{sub N}=140 K, the cubic system and perovskite type crystal. The average pressures used were 44 GPa and 74 GPa (300 K). SrFeO{sub 3} is paramagnetic material at 300 K, but the Neel temperature increases more than 300 K under high pressure and the quantized axis turns to the external magnetic field, so that we take it as it means the system displaying the phase transition to the ferromagnet. By the method, we can practice the measurement at low and high temperature under the external magnetic field by using the polarized light source. (S.Y.)

  8. High pressure gas driven liquid metal MHD homopolar generator

    International Nuclear Information System (INIS)

    Itoh, Yasuyuki

    1988-01-01

    A liquid metal MHD homopolar generator is proposed to be used as a high repetition rate pulsed power supply. In the generator, the thermal energy stored in a high pressure gas (He) reservoir is rapidly converted into kinetic energy of a rotating liquid metal (NaK) cylinder which is contracted by a gas driven annular free piston. The rotational kinetic energy is converted into electrical energy by making use of the homopolar generator principle. The conversion efficiency is calculated to be 47% in generating electrical energy of 20 kJ/pulse (1.7 MW peak power) at a repetition rate of 7 Hz. From the viewpoint of energy storage, the high pressure gas reservoir with a charging pressure of 15 MPa is considered to ''electrically'' store the energy at a density of 10 MJ/m 3 . (author)

  9. Mobility of negative ions in superfluid 3He

    International Nuclear Information System (INIS)

    Ahonen, A.I.; Kokko, J.; Lounasmaa, O.V.; Paalanen, M.A.; Richardson, R.C.; Schoepe, W.; Takano, Y.

    1976-01-01

    We have found that the mobility of negative ions increases rapidly below T/sub c/ in both superfluid 3 He phases. The ratio μ/μ/sub N/ of superfluid to normal mobility is larger in the B phase than in the A phase. A critical velocity consistent in magnitude with the Landau limit for pair breaking has also been observed. In the normal fluid we find a temperature-independent mobility between 30 mK and T/sub c/ for all pressures between 0 and 28 bars

  10. Measurements of the Spectral Light Emission from Decaying High Pressure Helium Plasmas

    International Nuclear Information System (INIS)

    Stevefelt, J.; Johansson, J.

    1971-04-01

    The rate of electron density decay has been determined in a helium pulsed discharge plasma at pressures ranging from 100 to 600 Torr, primarily during the early afterglow where the electron density is from 10 19 to 2 x 10 17 /m 3 . Measurements of the electrical conductivity and the absolute intensity of the light emission were made. The effective recombination rate coefficient was found to increase faster than linearly with gas pressure. The total photon emission rate was significantly lower than the effective recombination rate. Below 400 Torr pressure the afterglow was dominated by He-bands, which were related to the recombination of He 2 + and He 3 + ions. At higher pressures the appearance of intense lines originating from the atomic n = 3 and 2 3 P states is proposed to result from the He 4 + recombination. Absorption measurements of the atomic metastable concentration gave evidence for recombination directly into the 2 3 S state. The concentration of molecular metastables was surprisingly low. The light emission had a T e χ dependence, with 0 < χ < 0.35 for the intense atomic lines and 0.78 < χ < 1.10 for the molecular bands

  11. The depolarization performances of 0.97PbZrO3-0.03Ba(Mg1/3Nb2/3)O3 ceramics under hydrostatic pressure

    Science.gov (United States)

    Su, Rigu; Nie, Hengchang; Liu, Zhen; Peng, Ping; Cao, Fei; Dong, Xianlin; Wang, Genshui

    2018-02-01

    Several 0.97PbZrO3-0.03Ba(Mg1/3Nb2/3)O3 (0.97PZ-0.03BMN) ceramics were prepared via the columbite precursor method. Their microstructures and pressure-dependent ferroelectric and depolarization performances were then studied. The X-ray diffraction patterns of ground and fresh samples indicate that a main rhombohedral symmetry crystal structure is present in the bulk and that it sits alongside a trace quantity of an orthorhombic antiferroelectric phase that results from the effect of grinding on the surface. The remanent polarization (Pr) of the 0.97PZ-0.03BMN reached 32.4 μC/cm2 at 4.5 kV/mm and ambient pressure. In an in situ pressure-induced current measurement, more than 91% of the retained Pr of the pre-poled sample was released when the pressure was increased from 194 MPa to 238 MPa. That this pressure-driven depolarization should be attributed to the pressure-induced ferroelectric-antiferroelectric phase transition is supported by the emergence of double P-E loops at high hydrostatic pressures. Moreover, the 0.97PZ-0.03BMN ceramics exhibit no temperature-induced phase transitions and little related polarization loss up to 125 °C, which suggests that Pr has excellent thermal stability. The sharp depolarization behavior at low pressures and excellent temperature stability reveal that our 0.97PZ-0.03BMN ceramics exhibit superior performances in mechanical-electrical energy conversion applications.

  12. Time asymmetry: Polarization and analyzing power in the nuclear reactions

    Energy Technology Data Exchange (ETDEWEB)

    Rioux, C.; Roy, R.; Slobodrian, R.J. (Laval Univ., Quebec City (Canada). Lab. de Physique Nucleaire); Conzett, H.E. (California Univ., Berkeley (USA). Lawrence Berkeley Lab.)

    1983-02-28

    Measurements of the proton polarization in the reactions /sup 7/Li(/sup 3/He, p vector)/sup 9/Be and /sup 9/Be(/sup 3/He, p vector)/sup 11/B and of the analyzing powers of the inverse reactions, initiated by polarized protons at the same c.m. energies, show significant differences which imply the failure of the polarization-analyzing-power theorem and, prima facie, of time-reversal invariance in these reactions. The reaction /sup 2/H(/sup 3/He, p vector)/sup 4/ He and its inverse have also been investigated and show some smaller differences. A discussion of the instrumental asymmetries is presented.

  13. The superflow state of 3He-B at a diffusive wall. Quasiclassical calculations

    International Nuclear Information System (INIS)

    Kopnin, N.B.; Soininen, P.I.

    1992-01-01

    The authors report first computations considering effects of a rough wall on the counterflow state in superfluid 3 He-B for high flow velocities. Using the quasiclassical Green's-function formalism supplemented by the boundary conditions for a diffusive wall, they calculate the order-parameter field and the supercurrent near a container wall for various pressures and temperatures. One of the results is that the current density at the wall as a function of the flow has a maximum at the velocity which is about half of the pair breaking velocity

  14. The polarization of fast neutrons

    International Nuclear Information System (INIS)

    Talov, V.V.

    2001-01-01

    It is insufficient to know coordinates and momentum to describe a state of a neutron. It is necessary to define a spin orientation. As far as it is known from quantum mechanics, a half spin has a projection in the positive direction or in the negative direction. The probability of both projections in an unpolarized beam is equal. If a direction exists, in which the projection is more probably then beam is called polarized in this direction. It is essential to know polarization of neutrons for characteristics of a neutron source, which is emitting it. The question of polarization of fast neutrons came up in 50's. The present work is the review of polarization of fast neutrons and methods of polarization analysis. This also includes information about polarization of fast neutrons from first papers, which described polarization in the D(d,n) 3 He, 7 Li (p,n) 7 Be, T(p,n) 3 He reactions. (authors)

  15. Surface modification of polyester fabrics by atmospheric-pressure air/He plasma for color strength and adhesion enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chunming, E-mail: zcm1229@126.com [College of Textiles and Clothing, Qingdao University, Qingdao 266071 (China); Sunvim Grp Co Ltd, Gaomi 261500 (China); Zhao, Meihua; Wang, Libing; Qu, Lijun [College of Textiles and Clothing, Qingdao University, Qingdao 266071 (China); Men, Yajing [Sunvim Grp Co Ltd, Gaomi 261500 (China)

    2017-04-01

    Highlights: • Air/He plasma gave hydrophilicity on polyester surface and decreased contact angle to 18°. • The roughness of polyester increased and pit-like structures appeared on the surface after plasma treatment. • XPS confirmed the generation of new functional groups on polyester fabric. • The improved pigment color yield and anti-bleeding performance were contributed by the alteration of pigment adhesion. • The air/He plasma was more effective than air plasma at the same treatment time. - Abstract: Surface properties of water-based pigmented inks for ink-jet printed polyester fabrics were modified with atmospheric-pressure air/He plasma to improve the color strength and pigment adhesion of the treated surfaces. The influence of various parameters, including the surface morphology, chemical compositions, surface energy and dynamic contact angles of the control and plasma treated samples was studied. Color strength and edge definition were used to evaluate the ink-jet printing performance of fabrics. The change in pigment adhesion to polyester fibers was analyzed by SEM (scanning electron microscopy). AFM (Atomic force microscope) and XPS (X-ray photoelectron spectroscopy) analyses indicated the increase in surface roughness and the oxygen-containing polar groups(C=O, C−OH and COOH) reinforced the fixation of pigments on the fiber surface. The result from this study suggested that the improved pigment color yield was clearly affected by alteration of pigment adhesion enhanced by plasma surface modification. Polyester fabrics exhibited better surface property and ink-jet printing performance after the air/He mixture plasma treatment comparing with those after air plasma treatment.

  16. Surface modification of polyester fabrics by atmospheric-pressure air/He plasma for color strength and adhesion enhancement

    International Nuclear Information System (INIS)

    Zhang, Chunming; Zhao, Meihua; Wang, Libing; Qu, Lijun; Men, Yajing

    2017-01-01

    Highlights: • Air/He plasma gave hydrophilicity on polyester surface and decreased contact angle to 18°. • The roughness of polyester increased and pit-like structures appeared on the surface after plasma treatment. • XPS confirmed the generation of new functional groups on polyester fabric. • The improved pigment color yield and anti-bleeding performance were contributed by the alteration of pigment adhesion. • The air/He plasma was more effective than air plasma at the same treatment time. - Abstract: Surface properties of water-based pigmented inks for ink-jet printed polyester fabrics were modified with atmospheric-pressure air/He plasma to improve the color strength and pigment adhesion of the treated surfaces. The influence of various parameters, including the surface morphology, chemical compositions, surface energy and dynamic contact angles of the control and plasma treated samples was studied. Color strength and edge definition were used to evaluate the ink-jet printing performance of fabrics. The change in pigment adhesion to polyester fibers was analyzed by SEM (scanning electron microscopy). AFM (Atomic force microscope) and XPS (X-ray photoelectron spectroscopy) analyses indicated the increase in surface roughness and the oxygen-containing polar groups(C=O, C−OH and COOH) reinforced the fixation of pigments on the fiber surface. The result from this study suggested that the improved pigment color yield was clearly affected by alteration of pigment adhesion enhanced by plasma surface modification. Polyester fabrics exhibited better surface property and ink-jet printing performance after the air/He mixture plasma treatment comparing with those after air plasma treatment.

  17. High pressure studies of planetary matter

    International Nuclear Information System (INIS)

    Ross, M.

    1989-06-01

    Those materials which are of greatest interest to the physics of the deep planetary interiors are Fe, H 2 , He and the Ices. These are sufficiently diverse and intensively studied to offer an overview of present day high pressure research. 13 refs., 1 fig

  18. Effect of He pressure on the superconducting transition temperatures of Na2CsC60 and (NH3)4Na2CsC60

    International Nuclear Information System (INIS)

    Schirber, J.E.; Bayless, W.R.; Rosseinsky, M.J.; Zhou, O.; Fleming, R.M.; Murphy, D.; Fischer, J.E.

    1994-01-01

    The Na based mixed alkali doped C 60 superconductors show anomalous behavior with respect to the ''universal'' superconducting transition temperature T c vs lattice constant a 0 relation followed by most of the fcc A 3 C 60 superconductors. We have measured dt c /dP for Na 2 CsC 60 and (NH 3 ) 4 Na 2 CsC 60 using solid He as the pressure medium to ∼ 6 kbar finding dT c /dP equal to -0.8±(0.01) K/kbar and -1.0(±0.1)K/kbar for Na 2 CsC 60 and Na 2 (NH 3 ) 4 C 60 respectively. Our value for Na 2 CsC 60 differs markedly from that obtained by Mizuki et al of about -1.3 K/kbar. However, using N 2 or Ar, we obtain values for dT c /dP in substantial agreement with Mizuki et al who used fluorinert to generate their pressure. This work emphasizes the need for compressibility measurements with the same pressure medium in the appropriate temperature range so that meaningful comparisons can be made between various pressure measurements and models which are based on lattic spacing

  19. Giant asymmetry of separation and homogenization processes in solid 3He-4He solutions

    International Nuclear Information System (INIS)

    Grigor'ev, V.N.; Majdanov, V.A.; Penzev, A.A.; Polev, A.V.; Rubets, S.P.; Rudavskij, Eh.Ya.; Rybalko, A.S.; Syrnikov, E.V.

    2005-01-01

    The kinetics of the processes of separation and homogenization of solid 3 He- 4 He solutions is compared by using the precision barometry. The experiments were made with the initial specimens of three types: weak 3 He- 4 He and 4 He- 3 He solutions and concentrated 3 He- 4 He ones. It is found that the homogenization rate at the initial stage may be more than 500 times higher that the rate of separation. This is the case for all types of the solutions studied. The appreciable rate of phase separation in the concentrated solutions where, according to the modern concepts, impurity atoms in quantum crystals should be localized, suggests that in such conditions there is a new unknown mechanism of mass-transfer, while the fast homogenization points to a nondiffusion nature of the process

  20. Plate Tectonic Cycling and Whole Mantle Convection Modulate Earth's 3He/22Ne Ratio

    Science.gov (United States)

    Dygert, N. J.; Jackson, C.; Hesse, M. A.; Tremblay, M. M.; Shuster, D. L.; Gu, J.

    2016-12-01

    3He and 22Ne are not produced in the mantle or fractionated by partial melting, and neither isotope is recycled back into the mantle by subduction of oceanic basalt or sediment. Thus, it is a surprise that large 3He/22Ne variations exist within the mantle and that the mantle has a net elevated 3He/22Ne ratio compared to volatile-rich planetary precursor materials. Depleted subcontinental lithospheric mantle and mid-ocean ridge basalt (MORB) mantle have distinctly higher 3He/22Ne compared to ocean island basalt (OIB) sources ( 4-12.5 vs. 2.5-4.5, respectively) [1,2]. The low 3He/22Ne of OIBs approaches chondritic ( 1) and solar nebula values ( 1.5). The high 3He/22Ne of the MORB mantle is not similar to solar sources or any known family of meteorites, requiring a mechanism for fractionating He from Ne in the mantle and suggesting isolation of distinct mantle reservoirs throughout geologic time. We model the formation of a MORB source with elevated and variable 3He/22Ne though diffusive exchange between dunite channel-hosted basaltic liquids and harzburgite wallrock beneath mid-ocean ridges. Over timescales relevant to mantle upwelling beneath spreading centers, He may diffuse tens to hundreds of meters into wallrock while Ne is relatively immobile, producing a regassed, depleted mantle lithosphere with elevated 3He/22Ne. Subduction of high 3He/22Ne mantle would generate a MORB source with high 3He/22Ne. Regassed, high 3He/22Ne mantle lithosphere has He concentrations 2-3 orders of magnitude lower than undegassed mantle. To preserve the large volumes of high 3He/22Ne mantle required by the MORB source, mixing between subducted and undegassed mantle reservoirs must have been limited throughout geologic time. Using the new 3He/22Ne constraints, we ran a model similar to [3] to quantify mantle mixing timescales, finding they are on the order of Gyr assuming physically reasonable seafloor spreading rates, and that Earth's convecting mantle has lost >99% of its primordial

  1. Overlap integrals of model wave functions of 4He and 3He,3H nuclei

    International Nuclear Information System (INIS)

    Voloshin, N.I.; Levshin, E.B.; Fursa, A.D.

    1990-01-01

    Overlap integrals of wave functions 4 He nucleus and 3 He and 3 H nuclei are calculated. Two types of model wave functions are used to describe the structure of nuclei. The wace function is taken as a product of the one-particle Gaussian functions of the Gaussian type in the second case

  2. Optical studies of polarized-electron-noble-gas collisions

    International Nuclear Information System (INIS)

    Gay, T.I.; Furst, J.E.; Geesmann, H.; Khakoo, M.A.; Madison, D.H.; Wijayaratna, W.M.K.P.; Bartschat, K.

    1992-01-01

    We have measured the Stoke's parameters of light emitted following impact excitation of He and Xe by transversely-polarized electrons. For He, the 2 3 S-3 3 P, 389 nm transition was studied in an effort to systematically develop a highly accurate optical electron polarimeter. The 6 3 P 2 -6 3 D 3 , 882 nm transition in Xe was used to assess the importance of spin-dependent forces on the continuum electron for this target. We attempted (and failed) to made the first optical observations of Mott scattering. (Author)

  3. Advanced research capabilities for neutron science and technology: Neutron polarizers for neutron scattering

    International Nuclear Information System (INIS)

    Penttila, S.I.; Fitzsimmons, M.R.; Delheij, P.J.

    1998-01-01

    The authors describe work on the development of polarized gaseous 3 He cells, which are intended for use as neutron polarizers. Laser diode arrays polarize Rb vapor in a sample cell and the 3 He is polarized via collisions. They describe development and tests of such a system at LANSCE

  4. Crystal Growth and Characterization of (Bi0.5Na0.5)TiO3-BaTiO3 Single Crystals Obtained by a Top-Seeded Solution Growth Method under High-Pressure Oxygen Atmosphere

    Science.gov (United States)

    Onozuka, Hiroaki; Kitanaka, Yuuki; Noguchi, Yuji; Miyayama, Masaru

    2011-09-01

    A single crystal of ferroelectric 0.88(Bi,Na)TiO3-0.12BaTiO3 (BNT-BT) solid solution with tetragonal P4mm structure was grown by a top-seeded solution growth (TSSG) method at a high oxygen pressure (PO2 ) of 0.9 MPa. The crystals exhibited a large remanent polarization (Pr) of 54 µC/cm2, which leads to a spontaneous polarization estimated to be 54 µC/cm2. The large Pr compared with that of crystals grown at PO2 = 0.1 MPa is suggested to originate from a low oxygen vacancy concentration. The high-PO2 TSSG method is demonstrated to be effective for obtaining large-sized, high-quality BNT-BT crystals.

  5. Determination of the π3He3H coupling constant

    International Nuclear Information System (INIS)

    Nichitiu, F.; Sapozhnikov, M.G.

    1977-01-01

    Despersion relations for the real part of the antisymmetric amplitude of the π +-3 He scattering have been used in order to determine the π 3 He 3 H coupling constant. The coupling constant value determined by this method is larger than the elementary pion-nucleon coupling constant, but is in good agreement with the value obtained by another method. The obtained value is f 2 sub(π 3 He 3 H) = 0.12+-0.01. Shown is the importance of using the Coulomb corrections for dispersion relation calculations because the value of π 3 He 3 H coupling constant obtained with corrected total cross sections is larger by about 0.014 than the one obtained without these corrections. The best energy ranges for future π 3 He experiments are commented

  6. Helicity dependence of the γ {sup 3}He → πX reactions in the Δ(1232) resonance region

    Energy Technology Data Exchange (ETDEWEB)

    Costanza, S.; Rigamonti, F. [INFN, Sezione di Pavia, Pavia (Italy); Universita di Pavia, Dipartimento di Fisica, Pavia (Italy); Mushkarenkov, A.; Braghieri, A.; Pedroni, P. [INFN, Sezione di Pavia, Pavia (Italy); Romaniuk, M.; Mandaglio, G. [INFN, Sezione di Catania, Catania (Italy); Universita di Messina, Dipartimento di Fisica e Scienze della Terra, Messina (Italy); Aguar Bartolome, P.; Ahrens, J.; Arends, H.J.; Heid, E.; Jahn, O.; Kashevarov, V.L.; Ostrick, M.; Ortega, H.; Otte, P.B.; Oussena, B.; Schumann, S.; Thomas, A.; Unverzagt, M. [Universitaet Mainz, Institut fuer Kernphysik, Mainz (Germany); Annand, J.R.M.; Hamilton, D.; Howdle, D.; Livingston, K.; MacGregor, I.J.D.; Mancell, J.; McGeorge, J.C.; Rosner, G. [University of Glasgow, SUPA School of Physics and Astronomy, Glasgow (United Kingdom); Beck, R. [University of Bonn, Helmholtz-Institut fuer Strahlen und Kernphysik, Bonn (Germany); Bekrenev, V.; Kruglov, S.; Kulbardis, A. [Petersburg Nuclear Physics Institute, Gatchina (Russian Federation); Berghaeuser, H.; Drexler, P.; Metag, V.; Thiel, M. [University of Giessen, II Physikalisches Institut, Giessen (Germany); Briscoe, W.J.; Downie, E.J. [The George Washington University, Washington, DC (United States); Cherepnya, S.N.; Fil' kov, L.V.; Lisin, V.; Polonski, A. [Institute for Nuclear Research, Moscow (Russian Federation); Collicott, C. [Dalhousie University, Halifax, NS (Canada); Saint Mary' s University, Halifax, NS (Canada); Fix, A. [Tomsk Polytechnic University, Tomsk (Russian Federation); Glazier, D.I. [University of Glasgow, SUPA School of Physics and Astronomy, Glasgow (United Kingdom); University of Edinburgh, SUPA School of Physics and Astronomy, Edinburgh (United Kingdom); Heil, W.; Krimmer, J. [Universitaet Mainz, Institut fuer Physik, Mainz (Germany); Hornidge, D.; Middleton, D.G. [Mount Allison University, Sackville, NB (Canada); Jaegle, I.; Keshelashvili, I.; Krusche, B.; Oberle, M.; Pheron, F.; Rostomyan, T.; Werthmueller, D. [University of Basel, Institut fuer Physik, Basel (Switzerland); Huber, G.M. [University of Regina, Regina, SK (Canada); Jude, T.; Watts, D.P. [University of Edinburgh, SUPA School of Physics and Astronomy, Edinburgh (United Kingdom); Kondratiev, R. [Lebedev Physical Institute, Moscow (Russian Federation); Korolija, M.; Supek, I. [Rudjer Boskovic Institute, Zagreb (Croatia); Manley, D.M. [Kent State University, Kent, Ohio (United States); Nefkens, B.M.K.; Starostin, A. [University of California, Los Angeles, California (United States); Nikolaev, A. [Universita di Pavia, Dipartimento di Fisica, Pavia (Italy); Prakhov, S. [Universitaet Mainz, Institut fuer Kernphysik, Mainz (Germany); The George Washington University, Washington, DC (United States); University of California, Los Angeles, California (United States); Sarty, A.J. [Saint Mary' s University, Halifax, NS (Canada); Collaboration: A2 Collaboration

    2014-11-15

    The helicity dependences of the differential cross sections for the semi-inclusive γ {sup 3}He → π{sup 0} X and γ {sup 3}He → π{sup ±} X reactions have been measured for the first time in the energy region 200 < E{sub γ} 450 MeV. The experiment was performed at the tagged photon beam facility of the MAMI accelerator in Mainz using a longitudinally polarised high-pressure {sup 3}He gas target. Hadronic products were measured with the large-acceptance Crystal Ball detector complemented with additional devices for charged-particle tracking and identification. Unpolarised differential cross sections and their helicity dependence are compared with theoretical calculations using the Fix-Arenhoevel model. The effect of the intermediate excitation of the Δ(1232) resonance can be clearly seen from this comparison, especially for the polarised case, where nuclear effects are relatively small. The model provides a better theoretical description of the unpolarised charged pion photoproduction data than the neutral pion channel. It does significantly better in describing the helicity-dependent data in both channels. These comparisons provide new information on the mechanisms involved in pion photoproduction on {sup 3}He and suggest that a polarised {sup 3}He target can provide valuable information on the corresponding polarised quasi-free neutron reactions. (orig.)

  7. Development of data acquisition system for CSNS 3He detector

    International Nuclear Information System (INIS)

    Zhao Dongxu; Zhang Hongyu

    2012-01-01

    This paper introduces the research and development of data acquisition system of CSNS 3 He detector prototype. This system provides high performance data acquisition capability of CSNS 3 He detector, as well as several performance tests of electronics prototype. This data acquisition system establishes foundation for the later data acquisition development. (authors)

  8. Polarization: A must for fusion

    Directory of Open Access Journals (Sweden)

    Didelez J.-P.

    2013-11-01

    Full Text Available The complete polarization of DT fuel would increase the fusion reactivity by 50% in magnetic as well as in inertial confinements. The persistence of polarization in a fusion process could be tested, using a terawatt laser hitting a polarized HD target. The polarized deuterons heated in the plasma induced by the laser can fuse producing a 3He and a neutron in the final state. The angular distribution of the emitted neutrons and the change in the corresponding total Cross Section (CS can sign the polarization persistence. The polarization of solid H2, D2 or T2 Hydrogen isotopes is very difficult. However, it has been possible to polarize HD, a hetero-molecular form of Hydrogen, by static polarization, at very low temperature and very high field. The radioactivity of DT molecules forbids there high polarization by the static method, therefore one has to develop the Dynamic Nuclear Polarization (DNP by RF transitions. The DNP of HD has been investigated in the past. The magnetic properties of HD and DT molecules are very similar, it is therefore expected that any polarization result obtained with HD could be extrapolated to DT.

  9. Condensed matter at high shock pressures

    Energy Technology Data Exchange (ETDEWEB)

    Nellis, W.J.; Holmes, N.C.; Mitchell, A.C.; Radousky, H.B.; Hamilton, D.

    1985-07-12

    Experimental techniques are described for shock waves in liquids: Hugoniot equation-of-state, shock temperature and emission spectroscopy, electrical conductivity, and Raman spectroscopy. Experimental data are reviewed and presented in terms of phenomena that occur at high densities and temperatures in shocked He, Ar, N/sub 2/, CO, SiO/sub 2/-aerogel, H/sub 2/O, and C/sub 6/H/sub 6/. The superconducting properties of Nb metal shocked to 100 GPa (1 Mbar) and recovered intact are discussed in terms of prospects for synthesizing novel, metastable materials. Ultrahigh pressure data for Cu is reviewed in the range 0.3 to 6TPa (3 to 60 Mbar). 56 refs., 9 figs., 1 tab.

  10. Latest polarization and beam characterization results of the Orsay polarized electron source

    International Nuclear Information System (INIS)

    Arianer, J.; Cohen, S.; Essabaa, S.; Frascaria, R.; Zerhouni, O.

    1995-01-01

    The Orsay polarized electron source based on the chemi-ionization of aligned He(2 3 S 1 ) atoms and CO 2 molecules is briefly described. The latest results concerning electron polarization and beam emittance are presented. The present development status is also discussed. (K.A.)

  11. Structural phase transition of BaZrO3 under high pressure

    International Nuclear Information System (INIS)

    Yang, Xue; Li, Quanjun; Liu, Ran; Liu, Bo; Zhang, Huafang; Jiang, Shuqing; Zou, Bo; Cui, Tian; Liu, Bingbing; Liu, Jing

    2014-01-01

    We studied the phase transition behavior of cubic BaZrO 3 perovskite by in situ high pressure synchrotron X-ray diffraction experiments up to 46.4 GPa at room temperature. The phase transition from cubic phase to tetragonal phase was observed in BaZrO 3 for the first time, which takes place at 17.2 GPa. A bulk modulus 189 (26) GPa for cubic BaZrO 3 is derived from the pressure–volume data. Upon decompression, the high pressure phase transforms into the initial cubic phase. It is suggested that the unstable phonon mode caused by the rotation of oxygen octahedra plays a crucial role in the high pressure phase transition behavior of BaZrO 3

  12. Study of Interaction of Low-Energy Antiprotons with H$^{2}$,He$^{3}$,He$^{4}$,Ne-Nuclei Using a Streamer Chamber in Magnetic Field

    CERN Multimedia

    2002-01-01

    The aim of this experiment is the systematic study of the interaction between low-energy antiprotons and the H|2,~He|3,~He|4,~Ne-nuclei using a self shunted streamer chamber in a magnetic field exposed to the antiproton beam of the LEAR facility. The properties of the self shunted streamer chamber, which allows the use of the filling gas (hydrogen, helium, neon at a pressure of l~atm) as a target, permit to carry out experiments also in the very low-energy region. \\\\ \\\\ The experimental apparatus is suitable for a large programme of measurements. We plan to measure the @*H|2 cross section and the spectator momentum distributions at @* momenta lower than 250~MeV/c, where data are lacking. It is interesting to study for the first time the @*He|3 and @*He|4 interactions measuring the cross sections and the emitted particle distributions. Among other things the knowledge of the branching ratio of the @*He|4 annihilation channels clarifies some open cosmological questions. The study of the process of nuclear absor...

  13. Structure properties of the 3He-4He mixture at T = O K

    International Nuclear Information System (INIS)

    Boronat, J.; Polls, A.; Fabrocini, A.

    1993-01-01

    The spatial structure properties of 3 He- 4 He mixtures at T = O K are investigated using the hypernetted-chain formalism. The variational wave function used to describe the ground-state of the mixture is a simple generalization of the trial wave functions for pure phases and contains two- and three-body correlations. The elementary diagrams are taken into account by means of an extension of the scaling approximation to the mixtures. The two-body distribution (g (α,β) (r)) and the structure functions (S (α,β) (k)) together with the different spin-spin distribution functions for the 3 He component in the mixture are analyzed for several concentrations of 3 He. Two sum-rules, for the direct and the exchange part of the g (3,3) (r), are used to ascertain the importance of the full treatment of the Fermi statistics in the calculation. The statistical correlations are found responsible for the main differences between the several components of the distribution function. Due to its low concentration, 3 He behaves as a quasi-free Fermi gas, as far as the statistical correlations are concerned, although it is strongly correlated with the 4 He atoms through the interatomic potential

  14. Beamline 9.3.2 - a high-resolution, bend-magnet beamline with circular polarization capability

    Energy Technology Data Exchange (ETDEWEB)

    Moler, E.J.; Hussain, Z.; Howells, M.R. [Lawrence Berkeley National Lab., CA (United States)] [and others

    1997-04-01

    Beamline 9.3.2 is a high resolution, SGM beamline on an ALS bending magnet with access to photon energies from 30-1500 eV. Features include circular polarization capability, a rotating chamber platform that allows switching between experiments without breaking vacuum, an active feedback system that keeps the beam centered on the entrance slit of the monochromator, and a bendable refocusing mirror. The beamline optics consist of horizontally and vertically focussing mirrors, a Spherical Grating Monochromator (SGM) with movable entrance and exit slits, and a bendable refocussing mirror. In addition, a movable aperature has been installed just upstream of the vertically focussing mirror which can select the x-rays above or below the plane of the synchrotron storage ring, allowing the user to select circularly or linearly polarized light. Circularly polarized x-rays are used to study the magnetic properties of materials. Beamline 9.3.2 can supply left and right circularly polarized x-rays by a computer controlled aperture which may be placed above or below the plane of the synchrotron storage ring. The degree of linear and circular polarization has been measured and calibrated.

  15. Imaging and tuning polarity at SrTiO3 domain walls

    Science.gov (United States)

    Frenkel, Yiftach; Haham, Noam; Shperber, Yishai; Bell, Christopher; Xie, Yanwu; Chen, Zhuoyu; Hikita, Yasuyuki; Hwang, Harold Y.; Salje, Ekhard K. H.; Kalisky, Beena

    2017-12-01

    Electrostatic fields tune the ground state of interfaces between complex oxide materials. Electronic properties, such as conductivity and superconductivity, can be tuned and then used to create and control circuit elements and gate-defined devices. Here we show that naturally occurring twin boundaries, with properties that are different from their surrounding bulk, can tune the LaAlO3/SrTiO3 interface 2DEG at the nanoscale. In particular, SrTiO3 domain boundaries have the unusual distinction of remaining highly mobile down to low temperatures, and were recently suggested to be polar. Here we apply localized pressure to an individual SrTiO3 twin boundary and detect a change in LaAlO3/SrTiO3 interface current distribution. Our data directly confirm the existence of polarity at the twin boundaries, and demonstrate that they can serve as effective tunable gates. As the location of SrTiO3 domain walls can be controlled using external field stimuli, our findings suggest a novel approach to manipulate SrTiO3-based devices on the nanoscale.

  16. Symmetry-protected topological superfluids and superconductors. From the basics to 3He

    International Nuclear Information System (INIS)

    Mizushima, Takeshi; Tsutsumi, Yasumasa; Kawakami, Takuto; Sato, Masatoshi; Ichioka, Masanori; Machida, Kazushige

    2016-01-01

    In this article, we give a comprehensive review of recent progress in research on symmetry-protected topological superfluids and topological crystalline superconductors, and their physical consequences such as helical and chiral Majorana fermions. We start this review article with the minimal model that captures the essence of such topological materials. The central part of this article is devoted to the superfluid 3 He, which serves as a rich repository of novel topological quantum phenomena originating from the intertwining of symmetries and topologies. In particular, it is emphasized that the quantum fluid confined to nanofabricated geometries possesses multiple superfluid phases composed of the symmetry-protected topological superfluid B-phase, the A-phase as a Weyl superfluid, the nodal planar and polar phases, and the crystalline ordered stripe phase. All these phases generate noteworthy topological phenomena, including topological phase transitions concomitant with spontaneous symmetry breaking, Majorana fermions, Weyl superfluidity, emergent supersymmetry, spontaneous edge mass and spin currents, topological Fermi arcs, and exotic quasiparticles bound to topological defects. In relation to the mass current carried by gapless edge states, we also briefly review a longstanding issue on the intrinsic angular momentum paradox in 3 He-A. Moreover, we share the current status of our knowledge on the topological aspects of unconventional superconductors, such as the heavy-fermion superconductor UPt 3 and superconducting doped topological insulators, in connection with the superfluid 3 He. (author)

  17. Anomalous Quasiparticle Reflection from the Surface of a ^{3}He-^{4}He Dilute Solution.

    Science.gov (United States)

    Ikegami, Hiroki; Kim, Kitak; Sato, Daisuke; Kono, Kimitoshi; Choi, Hyoungsoon; Monarkha, Yuriy P

    2017-11-10

    A free surface of a dilute ^{3}He-^{4}He liquid mixture is a unique system where two Fermi liquids with distinct dimensions coexist: a three-dimensional (3D) ^{3}He Fermi liquid in the bulk and a two-dimensional (2D) ^{3}He Fermi liquid at the surface. To investigate a novel effect generated by the interaction between the two Fermi liquids, the mobility of a Wigner crystal of electrons formed on the free surface of the mixture is studied. An anomalous enhancement of the mobility, compared with the case where the 3D and 2D systems do not interact with each other, is observed. The enhancement is explained by the nontrivial reflection of 3D quasiparticles from the surface covered with the 2D ^{3}He system.

  18. Instrumentation with polarized neutrons

    International Nuclear Information System (INIS)

    Boeni, P.; Muenzer, W.; Ostermann, A.

    2009-01-01

    Neutron scattering with polarization analysis is an indispensable tool for the investigation of novel materials exhibiting electronic, magnetic, and orbital degrees of freedom. In addition, polarized neutrons are necessary for neutron spin precession techniques that path the way to obtain extremely high resolution in space and time. Last but not least, polarized neutrons are being used for fundamental studies as well as very recently for neutron imaging. Many years ago, neutron beam lines were simply adapted for polarized beam applications by adding polarizing elements leading usually to unacceptable losses in neutron intensity. Recently, an increasing number of beam lines are designed such that an optimum use of polarized neutrons is facilitated. In addition, marked progress has been obtained in the technology of 3 He polarizers and the reflectivity of large-m supermirrors. Therefore, if properly designed, only factors of approximately 2-3 in neutron intensity are lost. It is shown that S-benders provide neutron beams with an almost wavelength independent polarization. Using twin cavities, polarized beams with a homogeneous phase space and P>0.99 can be produced without significantly sacrificing intensity. It is argued that elliptic guides, which are coated with large m polarizing supermirrors, provide the highest flux.

  19. Measurements of the Spectral Light Emission from Decaying High Pressure Helium Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Stevefelt, J; Johansson, J

    1971-04-15

    The rate of electron density decay has been determined in a helium pulsed discharge plasma at pressures ranging from 100 to 600 Torr, primarily during the early afterglow where the electron density is from 1019 to 2 x 1017/m3. Measurements of the electrical conductivity and the absolute intensity of the light emission were made. The effective recombination rate coefficient was found to increase faster than linearly with gas pressure. The total photon emission rate was significantly lower than the effective recombination rate. Below 400 Torr pressure the afterglow was dominated by He-bands, which were related to the recombination of He{sub 2+} and He{sub 3+} ions. At higher pressures the appearance of intense lines originating from the atomic n = 3 and 23 P states is proposed to result from the He{sub 4+} recombination. Absorption measurements of the atomic metastable concentration gave evidence for recombination directly into the 23 S state. The concentration of molecular metastables was surprisingly low. The light emission had a Techi dependence, with 0 < chi < 0.35 for the intense atomic lines and 0.78 < chi < 1.10 for the molecular bands

  20. Polarized proton Target-III operators manual, revision A

    International Nuclear Information System (INIS)

    Hill, D.; Moretti, A.; Onesto, F.; Rynes, P.

    1976-04-01

    A revision is given of a manual containing standard operating procedures for the vacuum, cryogenic, and electronic systems of a polarized proton target. The discussion includes the target cryostat, the 3 He and 4 He pumping systems, remote monitors and controls, the microwave system, the magnet and power supply, the computerized polarization monitor, the 4 He liquifier and gas recovery system, and miscellaneous auxiliary equipment

  1. Rotational spectrum of the NH3He van der Waals complex

    Directory of Open Access Journals (Sweden)

    Surin L.

    2017-01-01

    Full Text Available The interaction between ammonia and helium has attracted considerable interest over many years, partly because of the observation of interstellar ammonia. The rate coefficients of NH3He scattering are an important ingredient for numerical modeling of astrochemical environments. Another, though quite different application in which the NH3He interaction can play an important role is the doping of helium clusters with NH3 molecules to perform high-resolution spectroscopy. Such experiments are directed on the detection of non-classical response of molecular rotation in helium clusters addressing fundamental questions related to the microscopic nature of superfluidity. High-resolution spectroscopy on the NH3He complex is an important tool for increasing our understanding of intermolecular forces between NH3 and He.

  2. 3He Abundances in Planetary Nebulae

    Science.gov (United States)

    Guzman-Ramirez, Lizette

    2017-10-01

    Determination of the 3He isotope is important to many fields of astrophysics, including stellar evolution, chemical evolution, and cosmology. The isotope is produced in stars which evolve through the planetary nebula phase. Planetary nebulae are the final evolutionary phase of low- and intermediate-mass stars, where the extensive mass lost by the star on the asymptotic giant branch is ionised by the emerging white dwarf. This ejecta quickly disperses and merges with the surrounding ISM. 3He abundances in planetary nebulae have been derived from the hyperfine transition of the ionised 3He, 3He+, at the radio rest frequency 8.665 GHz. 3He abundances in PNe can help test models of the chemical evolution of the Galaxy. Many hours have been put into trying to detect this line, using telescopes like the Effelsberg 100m dish of the Max Planck Institute for Radio Astronomy, the National Radio Astronomy Observatory (NRAO) 140-foot telescope, the NRAO Very Large Array, the Arecibo antenna, the Green Bank Telescope, and only just recently, the Deep Space Station 63 antenna from the Madrid Deep Space Communications Complex.

  3. Polarization memory of blue and red luminescence from nanocrystalline porous silicon treated by high-pressure water vapor annealing

    International Nuclear Information System (INIS)

    Gelloz, B.; Koyama, H.; Koshida, N.

    2008-01-01

    The polarization memory (PM) effect in the blue and red photoluminescence (PL) of p-type porous Si (PS) treated by high-pressure water vapor annealing (HWA) has been investigated. HWA induces a significant blue PL emission at about 450 nm, together with a drastic enhancement of the red PL intensity. The polarization memory of the red emission band is anisotropic and is in agreement with emission from quantum sized Si nanocrystals, whereas that of the blue band is high and isotropic, indicating an emission mechanism related to localized states in the amorphous Si oxide surrounding the Si skeleton of the PS layer after HWA. HWA does not induce any blue emission in PS that was electrochemically oxidized (ECO) beforehand because the electrochemically grown oxide tends to prevent the formation of blue-emitting amorphous oxide upon HWA. The PM of ECO-PS at low emission energies is anisotropic, but in a direction 45 deg. rotated compared to that of PS treated by HWA. This unique behavior may be related to the electrical nature of electrochemical oxidation. HWA increases the PM of ECO-PS. This could be attributed to the enhanced passivation induced by HWA

  4. Terrestrial cosmogenic 3He: where are we 30 years after its discovery?

    Science.gov (United States)

    Blard, Pierre-Henri; Pik, Raphaël; Farley, Kenneth A.; Lavé, Jérôme; Marrocchi, Yves

    2016-04-01

    It is now 30 years since cosmogenic 3He has been detected for the first time in a terrestrial sample (Kurz, 1986). 3He is now a widely used geochemical tool in many fields of Earth sciences: volcanology, tectonics, paleoclimatology. 3He has the advantage to have a high "production rate" to "detection limit" ratio, allowing surfaces as young as hundred of years to be dated. Although its nuclear stability implies several limitations, it moreover represents a useful alternative to 10Be in mafic environments. This contribution is a review of the progresses that have been accomplished since this discovery, and discuss strategies to improve both the accuracy and the precision of this geochronometer. 1) Measurement of cosmogenic 3He Correction of magmatic 3He. To estimate the non-cosmogenic magmatic 3He, Kurz (1986) invented a two steps method involving crushing of phenocrysts (to analyze the isotopic ratio of the magmatic component), followed by a subsequent melting of the sample, to extract the remaining components, including the cosmogenic 3He: 3Hec = 3Hemelt -4Hemelt x (3He/4He)magmatic (1) Several studies suggested that the preliminary crushing may induce a loss of cosmogenic 3He (Hilton et al., 1993; Yokochi et al., 2005; Blard et al., 2006), implying an underestimate of the cosmogenic 3He measurement. However, subsequent work did not replicate these observations (Blard et al., 2008; Goerhing et al., 2010), suggesting an influence of the used apparatus. An isochron method (by directly melting several phenocrysts aliquots) is an alternative to avoid the preliminary crushing step (Blard and Pik, 2008). Atmospheric contamination. Protin et al. (in press) provides robust evidences for a large and irreversible contamination of atmospheric helium on silicate surfaces. This unexpected behavior may reconcile the contrasted observations about the amplitude of crushing loss. This undesirable atmospheric contamination is negligible if grain fractions smaller than 150 mm are

  5. Quantitative and sensitive analysis of CN molecules using laser induced low pressure He plasma

    Energy Technology Data Exchange (ETDEWEB)

    Pardede, Marincan [Department of Electrical Engineering, University of Pelita Harapan, 1100 M.H. Thamrin Boulevard, Lippo Village, Tangerang 15811 (Indonesia); Hedwig, Rinda [Department of Computer Engineering, Bina Nusantara University, 9 K.H. Syahdan, Jakarta 14810 (Indonesia); Abdulmadjid, Syahrun Nur; Lahna, Kurnia; Idris, Nasrullah; Ramli, Muliadi [Department of Physics, Faculty of Mathematics and Natural Sciences, Syiah Kuala University, Darussalam, Banda Aceh 23111, NAD (Indonesia); Jobiliong, Eric [Department of Industrial Engineering, University of Pelita Harapan, 1100 M.H. Thamrin Boulevard, Lippo Village, Tangerang 15811 (Indonesia); Suyanto, Hery [Department of Physics, Faculty of Mathematics and Natural Sciences, Udayana University, Kampus Bukit Jimbaran, Denpasar 80361, Bali (Indonesia); Marpaung, Alion Mangasi [Department of Physics, Faculty of Mathematics and Natural Sciences, Jakarta State University, 10 Rawamangun, Jakarta 13220 (Indonesia); Suliyanti, Maria Margaretha [Research Center for Physics, Indonesia Institute of Sciences, Kawasan Puspiptek, Serpong, Tangerang Selatan, 15314 Banten (Indonesia); Tjia, May On [Physics of Magnetism and Photonics Group, Faculty of Mathematics and Natural Sciences, Bandung Institute of Technology, 10 Ganesha, Bandung 40132 (Indonesia); Research Center of Maju Makmur Mandiri Foundation, 40/80 Srengseng Raya, Jakarta 11630 (Indonesia); Lie, Tjung Jie; Lie, Zener Sukra; Kurniawan, Davy Putra; Kurniawan, Koo Hendrik, E-mail: kurnia18@cbn.net.id [Research Center of Maju Makmur Mandiri Foundation, 40/80 Srengseng Raya, Jakarta 11630 (Indonesia); Kagawa, Kiichiro [Research Center of Maju Makmur Mandiri Foundation, 40/80 Srengseng Raya, Jakarta 11630 (Indonesia); Fukui Science Education Academy, Takagi Chuou 2 choume, Fukui 910-0804 (Japan)

    2015-03-21

    We report the results of experimental study on CN 388.3 nm and C I 247.8 nm emission characteristics using 40 mJ laser irradiation with He and N{sub 2} ambient gases. The results obtained with N{sub 2} ambient gas show undesirable interference effect between the native CN emission and the emission of CN molecules arising from the recombination of native C ablated from the sample with the N dissociated from the ambient gas. This problem is overcome by the use of He ambient gas at low pressure of 2 kPa, which also offers the additional advantages of cleaner and stronger emission lines. The result of applying this favorable experimental condition to emission spectrochemical measurement of milk sample having various protein concentrations is shown to yield a close to linear calibration curve with near zero extrapolated intercept. Additionally, a low detection limit of 5 μg/g is found in this experiment, making it potentially applicable for quantitative and sensitive CN analysis. The visibility of laser induced breakdown spectroscopy with low pressure He gas is also demonstrated by the result of its application to spectrochemical analysis of fossil samples. Furthermore, with the use of CO{sub 2} ambient gas at 600 Pa mimicking the Mars atmosphere, this technique also shows promising applications to exploration in Mars.

  6. Facility for the measurement of proton polarization in nuclear reactions

    Energy Technology Data Exchange (ETDEWEB)

    Slobodrian, R J; Irshad, M; Labrie, R; Rioux, C; Roy, R; Pigeon, R [Laval Univ., Quebec City (Canada). Lab. de Physique Nucleaire

    1979-02-15

    A polarimetry facility based on high resolution and high efficiency silicon polarimeters with on-line particle identification is described. It has proven its capability to measure polarization in (/sup 3/He, p(pol)) reaction with cross section levels of 40 ..mu..b/sr.

  7. HD 185330 — chemically peculiar 3He star in the Kepler field

    Science.gov (United States)

    Niemczura, E.; Vennes, S.; Różański, T.; Pigulski, A.; Hełminiak, K.; Lehmann, H.

    2018-01-01

    We analyzed high-resolution spectra of the chemically peculiar 3He star HD 185330. We determined its atmospheric parameters (Teff, log g, ξ) and constrained its rotation velocity and abundance pattern. In particular, we found a large (×100) phosphorus abundance excess and evidence of 3He and 4He abundance stratification in the atmosphere.

  8. Measurement of the 3He Spin Structure Functions in the Resonance Region: A Test of Quark-Hadron Duality on the Neutron

    International Nuclear Information System (INIS)

    Patricia Solvignon

    2006-01-01

    One of the biggest challenges in the study of the nucleon structure is the understanding of the transition from partonic degrees of freedom to hadronic degrees of freedom. In 1970, Bloom and Gilman noticed that structure function data taken at SLAC in the resonance region average to the scaling curve of deep inelastic scattering (DIS). Early theoretical interpretations suggested that these two very different regimes can be linked under the condition that the quark-gluon and quark-quark interactions are suppressed. Substantial efforts are ongoing to investigate this phenomenon both experimentally and theoretically. Quark-hadron duality has been confirmed for the unpolarized structure function F 2 of the proton and the deuteron using data from the experimental Hall C at Jefferson Lab (JLab). Indications of duality have been seen for the proton polarized structure function g 1 and the virtual photon asymmetry A 1 at JLab Hall B and HERMES. Because of the different resonance behavior, it is expected that the onset of duality for the neutron will happen at lower momentum transfer than for the proton. Now that precise spin structure data in the DIS region are available at large x, data in the resonance region are greatly needed in order to test duality in spin-dependent structure functions. The goal of experiment E01-012 was to provide such data on the neutron ( 3 He) in the moderate momentum transfer (Q 2 ) region, 1.0 2 2 ), where duality is expected to hold. The experiment ran successfully in early 2003 at Jefferson Lab in Hall B. It was an inclusive measurement of longitudinally polarized electrons scattering from a longitudinally or transversely polarized 3 He target. Asymmetries and cross section differences were measured in order to extract the 3 He spin structure function g 1 and virtual photon asymmetry A 1 in the resonance region. A test of quark-hadron duality has then been performed for the 3 He and neutron structure functions. The study of spin duality for

  9. Pressure response of vacancy ordered maghemite (γ-Fe2O3) and high pressure transformed hematite (α-Fe2O3)

    International Nuclear Information System (INIS)

    Hearne, Giovanni; Pischedda, Vittoria

    2012-01-01

    Combined XRD and Mössbauer effect spectroscopy studies to high pressures of ∼30 GPa of vacancy ordered maghemite are presented. The vacancy ordered superstructure is robust and remains intact up to the pressure-induced onset transition to hematite at 13–16 GPa. The pressure transformed hematite is shown to be crystallographically textured, unlike the randomised low pressure maghemite phase. This arises out of a pressure or stress instigated topotactic transformation of the cubic-spinel to hexagonal-corundum structure. The textured sample permits us to obtain information on the spin reorientation behavior of the pressure transformed hematite in compression and decompression sequences. Spin reorientation is restricted to ∼15° over wide pressure ranges, attributable to the effect of entrapped vacancies in the high pressure structure. Thus there are structural and magnetic peculiarities specific to pressure transformed hematite not evident in pressurized hematite starting material. These are triggered by the maghemite→hematite transformation. - Graphical abstract: Pressure instigated topotactic transformation of vacancy ordered γ-Fe 2 O 3 →α-Fe 2 O 3 . There is restricted spin (B hf ) reorientation in the new pressure transformed hematite due to entrapped vacancies. The change in direction of V zz signifies a distortion of the FeO 6 octahedral local environment. Highlights: ► Robust vacancy ordered superstructure in maghemite to high pressures. ► Pressure instigated topotactic transformation to hematite and subsequent texture. ► Defect trapping in the pressure transformed hematite. ► Entrapped defects restricts spin reorientation in pressure transformed hematite. ► Contrasting behavior with pressurized hematite starting material.

  10. Cosmogenic 10Be production rate calibrated against 3He in the high Tropical Andes (3800-4900 m, 20-22° S)

    Science.gov (United States)

    Blard, P.-H.; Braucher, R.; Lavé, J.; Bourlès, D.

    2013-11-01

    Many geomorphologic applications, notably glacier chronologies, require improvements in both the precision and the accuracy of the cosmogenic dating tool. Of particular importance is the need to better constrain the spatial variability of the cosmogenic nuclides production rates at high elevation and low latitudes. One strategy that can be adopted for this is to couple absolute calibrations, from independently dated surfaces, with cross-calibration studies, performed by measuring several cosmogenic nuclides in the same rock. In the present study, we report the highest-elevation (>4800 m) cross-calibration published to date, comprising measurements of cosmogenic 3He and 10Be in cogenetic pyroxene and quartz. The samples were collected from six dacitic moraine boulders, exposed from 32 to 65 ka at 4820 m on the flanks of the Uturuncu volcano (22° S, 67° W), Southern Lipez (Bolivia). The samples yield a remarkably tight cluster of 3He-10Be production ratios, with a weighted mean of 33.3±0.9 (1σ). This production ratio is undistinguishable, within uncertainties, from the 3He-10Be production ratio of 32.3±0.9 determined in the same mineral pair at low elevation (1333 m) by Amidon et al. (2009). These results agree at the 1σ level and suggest that any hypothetical increase of the 3He-10Be production ratio in pyroxene and quartz is likely to be lower than 5% over this elevation range (1000-5000 m). Moreover, the production ratio is almost insensitive to the Li content of the pyroxene (20 to 50 ppm Li), suggesting that the cosmogenic thermal neutron production of 3He is very low in this setting. The high-elevation 3He-10Be production ratio is used in combination with a local determination of the 3He production rate in the high Central Altiplano (3800 m) (Blard et al., 2013) to establish a local 10Be production rate of 30.0±1.4 at g yr at 3800 m and 20° S. After scaling to sea-level high latitude with the time-dependent Lal/Stone model, this yields a 10Be production

  11. Collisional energy transfer in Na(4p--3d)--He,H2 collisions

    International Nuclear Information System (INIS)

    Kleiber, P.D.; Wong, T.H.; Bililign, S.

    1993-01-01

    We have investigated the direct collisional energy transfer process Na*(4p)+M→Na*(3d)+M, where M=He,H 2 under gas cell conditions. We have measured the temporal profiles of the Na(3d--3p) sensitized fluorescence as a function of quenching gas pressure and fit the profiles to a two-state rate equation model to obtain the quenching rate coefficients from the Na*(4p) state. The total energy transfer rate coefficient out of the 4p state for He is small [(0.5±0.2)x10 -10 cm 3 /s]. The total quenching rate coefficient out of the 4p state is much larger for H 2 [(3.9±0.5)x10 -10 cm 3 /s]. Evidence suggests that the energy transfer rate coefficient for the 4p--3d process is ∼2.0x10 -10 cm 3 /s with the remainder of the 4p quenching being predominantly reactive. We also compare the far-red wing absorption line shapes for the NaHe and NaH 2 systems

  12. Determination of the nuclear induced electrical conductivity of 3He for magnetohydrodynamic energy conversion

    International Nuclear Information System (INIS)

    Bitteker, L.; Scheuer, J.; Howe, S.

    1996-01-01

    This is the final report for a one-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The continual need for more efficient, high-output energy conversion techniques has renewed interest in nuclear-driven magnetohydrodynamic (MHD) energy conversion. To provide the fundamental knowledge required to evaluate the potential value of this concept, a one-year project aimed at measuring the nuclear-induced electrical conductivity of a 3 He/ 4 He gas mixture under thermodynamic conditions consistent with the MHD flow conditions was carried out. The range of bulk gas conditions to be considered were: pressure = 0.1 to 3800 Torr and temperature = 300 to 1500 K. The maximum neutron flux to be considered was 10 16 /cm 2 sec. The range of parameters considered surpassed previous experiments in all aspects

  13. Variations of 3/He/4He isotope ratios within the Broadlands geothermal field, New Zealand

    International Nuclear Information System (INIS)

    Hulston, John; Lupton, John; University of California, Santa Barbara; Rosenberg, Nina

    1986-01-01

    The Broadlands-Ohaaki geothermal field is located 20 km NE of Wairakei on the Central Volcanic Zone of New Zealand. It falls within a resistivity low extending 4 km by 3 km. A study of 3 He/ 4 He ratios within this field has shown R/R A ratios close to 6.0 in the Ohaaki production area (NW). In contrast the production area to the SE on the east bank of the Waikato River has R/R A values close to 3.5. Differences in chemical ratios reported previously are found to correlate with the 3 He/ 4 He measurements. A tentative interpretation of the results indicate that there is a contribution of 3 He from the mantle and that the variations in the 3 He/ 4 He ratios are probably related to differences in the geochemistry of the rocks through which the geothermal fluids flow to the surface. Preliminary measurements of the argon isotopes also show a contribution from radiogenic rocks at depth

  14. High pressure study of high-temperature superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Souliou, Sofia-Michaela

    2014-09-29

    The current thesis studies experimentally the effect of high external pressure on high-T{sub c} superconductors. The structure and lattice dynamics of several members of the high-T{sub c} cuprate and Fe-based superconductors families were investigated by means of Raman spectroscopy and X-ray diffraction under well-controlled, hydrostatic high pressure and low temperature conditions. The lattice dynamics of the high-T{sub c} superconductor YBa{sub 2}Cu{sub 3}O{sub 6+x} have been investigated systematically by Raman spectroscopy as a function of doping (x = 0.95, 0.75, 0.60, 0.55, and 0.45) and external pressure. Under ambient pressure conditions, in addition to the Raman modes expected from group theory, we observe new Raman active phonons upon cooling the underdoped samples, at temperatures well above the superconducting transition temperature. The doping dependence and the onset temperatures of the new Raman features suggest that they are associated with the incommensurate charge density wave (CDW) state recently discovered in underdoped cuprates using synchrotron X-ray scattering techniques. Under high pressure conditions (from 2 to 12 GPa), our Raman measurements on highly ordered underdoped YBa{sub 2}Cu{sub 3}O{sub 6.55} samples do not show any of the new Raman phonons seen at ambient pressure. High pressure and low temperature Raman measurements have been performed on the underdoped superconductor YBa{sub 2}Cu{sub 4}O{sub 8}. A clear renormalization of some of the Raman phonons is seen below T{sub c} as a result of the changes in the phonon self-energy upon the opening of the superconducting gap, with the most prominent one being that of the B{sub 1g}-like buckling phonon mode. The amplitude of this renormalization strongly increases with pressure, resembling the effect of hole doping in YBa{sub 2}Cu{sub 3}O{sub 6+x}. At ∝ 10 GPa, the system undergoes a reversible pressure-induced structural phase transition to a non-centrosymmmetric structure (space group

  15. High pressure study of high-temperature superconductors

    International Nuclear Information System (INIS)

    Souliou, Sofia-Michaela

    2014-01-01

    The current thesis studies experimentally the effect of high external pressure on high-T c superconductors. The structure and lattice dynamics of several members of the high-T c cuprate and Fe-based superconductors families were investigated by means of Raman spectroscopy and X-ray diffraction under well-controlled, hydrostatic high pressure and low temperature conditions. The lattice dynamics of the high-T c superconductor YBa 2 Cu 3 O 6+x have been investigated systematically by Raman spectroscopy as a function of doping (x = 0.95, 0.75, 0.60, 0.55, and 0.45) and external pressure. Under ambient pressure conditions, in addition to the Raman modes expected from group theory, we observe new Raman active phonons upon cooling the underdoped samples, at temperatures well above the superconducting transition temperature. The doping dependence and the onset temperatures of the new Raman features suggest that they are associated with the incommensurate charge density wave (CDW) state recently discovered in underdoped cuprates using synchrotron X-ray scattering techniques. Under high pressure conditions (from 2 to 12 GPa), our Raman measurements on highly ordered underdoped YBa 2 Cu 3 O 6.55 samples do not show any of the new Raman phonons seen at ambient pressure. High pressure and low temperature Raman measurements have been performed on the underdoped superconductor YBa 2 Cu 4 O 8 . A clear renormalization of some of the Raman phonons is seen below T c as a result of the changes in the phonon self-energy upon the opening of the superconducting gap, with the most prominent one being that of the B 1g -like buckling phonon mode. The amplitude of this renormalization strongly increases with pressure, resembling the effect of hole doping in YBa 2 Cu 3 O 6+x . At ∝ 10 GPa, the system undergoes a reversible pressure-induced structural phase transition to a non-centrosymmmetric structure (space group Imm2). The structural transition is clearly reflected in the high pressure

  16. Angular dependence of the sup(6)Li(πsup(+),sup(3)He)sup(3)He reaction

    International Nuclear Information System (INIS)

    McParland, B.J.; Auld, E.G.; Couvert, P.

    1985-02-01

    Angular distributions of the differential cross sections for the pionic fission sup(6)Li(πsup(+),sup(3)He)sup(3)He have been measured at pion energies of 60 and 80 MeV. The differential cross section is found to decrease monotonically with cossup(2)thetasup(*) and is compared with a theoretical prediction

  17. Spectral simulations of polar diatomic molecules immersed in He clusters: application to the ICl (X) molecule

    International Nuclear Information System (INIS)

    Villarreal, P; Lara-Castells, M P de; Prosmiti, R; Delgado-Barrio, G; Lopez-Duran, D; Gianturco, F A; Jellinek, J

    2007-01-01

    A recently developed quantum-chemistry-like methodology to study molecules solvated in atomic clusters is applied to the ICl (iodine chloride) polar diatomic molecule immersed in clusters of He atoms. The atoms of the solvent clusters are treated as the 'electrons' and the solvated molecule as a structured 'nucleus' of the combined solvent-solute system. The helium-helium and helium-dopant interactions are represented by parametrized two-body and ab initio three-body potentials, respectively. The ground-state wavefunctions are used to compute the infrared (IR) spectra of the solvated molecule. In agreement with the experimental observations, the computed spectra exhibit considerable differences depending on whether the solvent cluster is comprised of bosonic ( 4 He) or fermionic ( 3 He) atoms. The source of these differences is attributed to the different spin-statistics of the solvent clusters. The bosonic versus fermionic nature of the solvent is reflected in the IR absorption selection rules. Only P and R branches with single state transitions appear in the spectrum when the molecule is solvated in a bosonic cluster. On the other hand, when the solvent represents a fermionic environment, quasi-degenerate multiplets of spin states contribute to each branch and, in addition, the Q-branch becomes also allowed. Combined, these two factors explain the more congested nature of the spectrum in the fermionic case

  18. Neutron scattering lengths of 3He

    International Nuclear Information System (INIS)

    Alfimenkov, V.P.; Akopian, G.G.; Wierzbicki, J.; Govorov, A.M.; Pikelner, L.B.; Sharapov, E.I.

    1976-01-01

    The total neutron scattering cross-section of 3 He has been measured in the neutron energy range from 20 meV to 2 eV. Together with the known value of coherent scattering amplitude it leads to the two sts of n 3 He scattering lengths

  19. Designing an Epithermal Neutron Beam for Boron Neutron Capture Therapy for the Fusion Reactions 2H(d,n)3He and 3H(d,n)4He1

    International Nuclear Information System (INIS)

    Verbeke, J.M.; Costes, S.V.; Bleuel, D.; Vujic, J.; Leung, K.N.

    1998-01-01

    A beam shaping assembly has been designed to moderate high energy neutrons from the fusion reactions 2 H(d,N) 3 He and 3 H(d,n) 4 He for use fin boron neutron capture therapy. The low neutron yield of the 2 H(d,n) 3 He reaction led to unacceptably long treatment times. However, a 160 mA deuteron beam of energy 400 keV led to a treatment time of 120 minutes with the reaction 3 H(d,n) 4 He. Equivalent doses of 9.6 Gy-Eq and 21.9 Gy-Eq to the skin and to a 8 cm deep tumor respectively have been computed

  20. Spin polarized electron source technology transferred from HE accelerators to electron microscopes

    International Nuclear Information System (INIS)

    Nakanishi, Tsutomu

    2009-01-01

    For many years, we have developed a technology of spin-polarized-electron-source (PES) for a future linear collider project (ILC). Various new techniques for achieving high polarization, high quantum efficiency, high current density, sub-nanosecond multi-bunch generation etc. were developed. Two fundamental technologies; reduction of dark current and preparation of extremely high vacuum environment to protect the Negative Electron Affinity (NEA) surface have been also developed. Using these PES technologies and a new transmission type photocathode, we recently succeeded in producing the high brightness and high polarization electron beam for the low energy electron microscope (LEEM). Our Spin-LEEM system enables the world-first dynamic observation of surface magnetic domain formed by evaporation on the metal substrate with ∼ 20 nm space resolutions. (author)

  1. Electron motion in high-pressure polar gases: NH3

    International Nuclear Information System (INIS)

    Christophorou, L.G.; Carter, J.G.; Maxey, D.V.

    1982-01-01

    Drift velocities w for slow electrons in NH 3 vapor have been measured and are reported as a function of the density-reduced electric field E/N ( -17 V cm 2 ), density N (2.43--292 x 10 18 molecule cm -3 ), and temperature T (300--650 K). The w decreases with increasing N considerably and this decrease varies with T; for a fixed N it is higher the lower the T. Use is made of the T- and N-dependence of w to assess the role of the various processes which delay the electron drift. The density range above approx.2.5 x 10 19 molecules cm -3 seems (anionic) electron state. The number density N/sub L/ at which complete electron localization occurs, has been estimated at various T. At T = 300 K, N/sub L/approx. =3.3 x 10 20 molecule cm -3 or approx.0.01 g cm 3 . Estimates have also been made of the binding energy of the electron to the trapping species (possibly NH 3 clusters) which, depending on T, range from 0.11 to 0.15 eV

  2. Acceleration of polarized proton in high energy accelerators

    International Nuclear Information System (INIS)

    Lee, S.Y.

    1991-01-01

    In low to medium energy accelerators, betatron tune jumps and vertical orbit harmonic correction methods have been used to overcome the intrinsic and imperfection resonances. At high energy accelerators, snakes are needed to preserve polarization. The author analyzes the effects of snake resonances, snake imperfections, and overlapping resonances on spin depolarization. He discusses also results of recent snake experiments at the IUCF Cooler Ring. The snake can overcome various kinds of spin depolarization resonances. These experiments pointed out further that partial snake can be used to cure the imperfection resonances in low to medium energy accelerators

  3. Apparent violation of isospin symmetry in the 3H(3He,2H)4He reaction

    International Nuclear Information System (INIS)

    Rai, G.; Blyth, C.O.; England, J.B.A.; Farooq, A.; Karban, O.; Rawas, E.; Roman, S.; Vlastou, R.

    1988-01-01

    Angular distributions of the vector analyzing powers for the 3 H( 3 He, 2 H) 4 He reaction have been measured over the incident energy range 18--33 MeV. The measurements centered about 18 MeV display a deviation from the antisymmetric shape expected from isospin symmetry. Concentrating on the explanation of the 90 0 analyzing powers, we report the results of a distorted-wave Born approximation (DWBA) analysis which includes the direct and exchange processes and the spin-orbit potential. It is shown that the anomalous behavior of the 90 0 vector analyzing powers can be largely explained by the effect of a single F-wave potential resonance which leads to the magnification of the short-range differences between the 3 He and 3 H wave functions

  4. 12C(3He,3He n)11C cross section at 910 MeV

    International Nuclear Information System (INIS)

    Aslanides, E.; Fassnacht, P.; Dellacasa, G.; Gallio, M.; Tuyn, J.W.N.

    1981-01-01

    The 12 C( 3 He, 3 He n) 11 C cross section at 910 MeV was measured by using a Ge(Li) gamma spectrometer to determine the disintegration rate and measuring the incident flux by means of a scintillator telescope. Cross sections for the production of 7 Be in C and Al and for the production of 24 Na in Al are then determined using the measured cross section as a monitor

  5. CAST search for sub-eV mass solar axions with $^{3}$He buffer gas

    CERN Document Server

    Aune, S; Belov, A; Borghi, S; Brauninger, H; Cantatore, G; Carmona, J M; Cetin, S A; Collar, J I; Dafni, T; Davenport, M; Eleftheriadis, C; Elias, N; Ezer, C; Fanourakis, G; Ferrer-Ribas, E; Friedrich, P; Galan, J; Garcia, J A; Gardikiotis, A; Gazis, E N; Geralis, T; Giomataris, I; Gninenko, S; Gomez, H; Gruber, E; Guthorl, T; Hartmann, R; Haug, F; Hasinoff, M D; Hoffmann, D H H; Iguaz, F J; Irastorza, I G; Jacoby, J; Jakovcic, K; Karuza, M; Konigsmann, K; Kotthaus, R; Krcmar, M; Kuster, M; Lakic, B; Laurent, J M; Liolios, A; Ljubicic, A; Lozza, V; Lutz, G; Luzon, G; Morales, J; Niinikoski, T; Nordt, A; Papaevangelou, T; Pivovaroff, M J; Raffelt, G; Rashba, T; Riege, H; Rodriguez, A; Rosu, M; Ruz, J; Savvidis, I; Silva, P S; Solanki, S.K; Stewart, L; Tomas, A; Tsagri, M; van Bibber, K; Vafeiadis, T; Villar, J A; Vogel, J K; Yildiz, S C; Zioutas, K

    2011-01-01

    The CERN Axion Solar Telescope (CAST) has extended its search for solar axions by using 3He as a buffer gas. At T=1.8 K this allows for larger pressure settings and hence sensitivity to higher axion masses than our previous measurements with 4He. With about 1 h of data taking at each of 252 different pressure settings we have scanned the axion mass range 0.39 eV < m_a < 0.64 eV. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 2.3 x 10^{-10} GeV^{-1} at 95% CL, the exact value depending on the pressure setting. KSVZ axions are excluded at the upper end of our mass range, the first time ever for any solar axion search. In future we will extend our search to m_a < 1.15 eV, comfortably overlapping with cosmological hot dark matter bounds.

  6. X-ray diffraction study of WO3 at high pressure

    International Nuclear Information System (INIS)

    Bouvier, P.; Crichton, W.A.; Boulova, M.; Lucazeau, G.

    2002-01-01

    The high-pressure behaviour of microcrystalline tungsten oxide (WO 3 ) has been investigated with angle-dispersive synchrotron x-ray powder diffraction in a diamond anvil cell up to 40 GPa at room temperature. Up to 21 GPa, the pressure dependence of the volume of the monoclinic high-pressure (P2 1 /c) phase is described by a third-order Birch-Murnaghan equation of state with parameters V 0 =210.9(7)A 3 , K T =27(2)GP a and K'=9.4(5). At 24 GPa, a first-order phase transition occurs with an approximate Δ V of 7.4% to a monoclinic P2 1 /a unit cell with a=6.1669(8)A, b=4.5758(6)A, c=5.3159(6)A, β=101.440(9) deg. A second transition is observed at pressures higher than 31 GPa with an approximate Δ V of 12% to a phase described by a third monoclinic unit cell, with a=10.3633(22)A, b=3.9065(8)A, c=9.3459(18)A and β=98.539(14) deg. (author)

  7. Precise measurement of magnetic field gradients from free spin precession signals of He-3 and Xe-129 magnetometers

    NARCIS (Netherlands)

    Allmendinger, Fabian; Blümler, Peter; Doll, Michael; Grasdijk, Oliver; Heil, Werner; Jungmann, Klaus; Karpuk, Sergej; Krause, Hans-Joachim; Offenhäuser, Andreas; Repetto, Maricel; Schmidt, Ulrich; Sobolev, Yuri; Tullney, Kathlyne; Willmann, Lorenz; Zimmer, Stefan

    2017-01-01

    We report on precise measurements of magnetic field gradients extracted from transverse relaxation rates of precessing spin samples. The experimental approach is based on the free precession of gaseous, nuclear spin polarized He-3 and (12)9Xe atoms in a spherical cell inside a magnetic guiding field

  8. Optimising neutron polarizers--measuring the flipping ratio and related quantities

    CERN Document Server

    Goossens, D J

    2002-01-01

    The continuing development of gaseous spin polarized sup 3 He transmission filters for use as neutron polarizers makes the choice of optimum thickness for these filters an important consideration. The 'quality factors' derived for the optimisation of transmission filters for particular measurements are general to all neutron polarizers. In this work optimisation conditions for neutron polarizers are derived and discussed for the family of studies related to measuring the flipping ratio from samples. The application of the optimisation conditions to sup 3 He transmission filters and other types of neutron polarizers is discussed. Absolute comparisons are made between the effectiveness of different types of polarizers for this sort of work.

  9. Spin-dependent electron emission from metals in the neutralization of He+ ions

    International Nuclear Information System (INIS)

    Alducin, M.; Roesler, M.; Juaristi, J.I.; Muino, R. Diez; Echenique, P.M.

    2005-01-01

    We calculate the spin-polarization of electrons emitted in the neutralization of He + ions interacting with metals. All stages of the emission process are included: the spin-dependent perturbation induced by the projectile, the excitation of electrons in Auger neutralization processes, the creation of a cascade of secondaries, and the escape of the electrons through the surface potential barrier. The model allows us to explain in quantitative terms the measured spin-polarization of the yield in the interaction of spin-polarized He + ions with paramagnetic surfaces, and to disentangle the role played by each of the involved mechanisms. We show that electron-electron scattering processes at the surface determine the spin-polarization of the total yield. High energy emitted electrons are the ones providing direct information on the He + ion neutralization process and on the electronic properties of the surface

  10. Polarization and pressure effects in caesium 6S-8S two-photon spectroscopy

    International Nuclear Information System (INIS)

    Lee, Yi-Chi; Tsai, Chin-Chun; Chui, Hsiang-Chen; Chang, Yi-Hsiu; Chen, Ying-Yu

    2010-01-01

    This work analyses the effects of polarization and pressure in caesium 6S-8S two-photon spectroscopy. The linewidth was broadened and the frequency was shifted by a change of polarization states. The frequency shift and the linewidth broadening of the caesium 6S-8S two-photon transition were measured as a function of laser power using one single-frequency Ti:sapphire ring cavity laser, two caesium cells and two quarter-wave plates to ensure polarization states of light, and we showed that the linewidth cannot be evaluated just by fitting data to a Lorentzian shape. As determined by fitting the data to a Voigt profile, the natural linewidth is independent of the polarization states of the pump beams, the laser power and the pressure. Caesium 6S-8S two-photon transitions pumped by a circularly polarized beam have narrower linewidths and smaller shifts than those pumped by a linearly polarized beam. The light shift obtained by pumping with the circularly polarized beam is -6.75(57) Hz (mW mm -2 ) -1 , and that obtained by pumping with a linearly polarized beam is -7.25(45) Hz (mW mm -2 ) -1 . These results agree closely with theoretical calculations. The pressure shift is -588(387) Hz mPa -1 . This work shows how to evaluate two-photon transitions with a Voigt profile, and then helps us to understand two-photon transitions with different polarization states, and improve the signal quality obtained when they are used as frequency markers.

  11. 3He impurities on liquid 4He: possible existence of excited states

    International Nuclear Information System (INIS)

    Pavloff, N.; Treiner, J.

    1989-01-01

    We study, using a density functional approach, the properties of the two dimensional system formed by 3 He atoms on the surface of liquid 4 He, as a function of 3 He coverage N s . We find that the excited state recently proposed by Dalfovo and Stringari in the case of infinite dilution does survive when the number of surface 3 He atoms increases. For small values of N s , the surface tension σ is, as expected, linear in N s 2 . For N s ≅0.035 atom per square-Angstrom, i.e. half a monolayer, a new type of surface state starts being occupied, and this feature manifests itself by a change in the slope of σ as a function of N s 2 and, more clearly, by a discontinuity in the surface specific heat, which increases by a factor of almost 2. These predictions call for experimental investigations

  12. Radiogenic 3He/4He Estimates and Their Effect on Calculating Plio-Pleistocene Cosmogenic 3He Ages of Alluvial-Fan Terraces in the Lower Colorado River Basin, USA

    Science.gov (United States)

    Fenton, C.; Pelletier, J.

    2005-12-01

    Several alluvial-fan terraces near Topock, AZ were created by successive entrenchment of Pliocene and Pleistocene alluvial-fan gravels shed from the adjacent Black Mountains along the lower Colorado River corridor below Hoover Dam. These fans interfinger with and overlie main-stem Colorado River sands and gravels and grade to terrace levels that correspond with pre-existing elevations of the Colorado River. Absolute dates for the ages of Quaternary deposits on the lower Colorado River are rare and cosmogenic 3He age estimates of these surfaces would help constrain the timing of aggradation and incision in the lower Colorado River corridor. We analyzed individual basalt boulders from several terrace surfaces for total 3He/4He concentrations to calculate cosmogenic 3He ages of each fan terrace; 3He/4He values, expressed as R/Ra where Ra is the 3He/4He of air, range from 0.29 to 590. Black Mountain volcanic rocks have reported K-Ar ages between 15 and 30 Ma and basalt samples from adjacent alluvial fans contain 0.42 to 47× 1012 at/g of 4He, which has likely accumulated due to nuclear processes. The amount of radiogenic 3He/4He can be significant in old rocks with young exposure ages and can complicate determination of cosmogenic 3 He content. Alpha-decay of U, Th, and their daughter isotopes produces large amounts of 4He, whereas significant amounts of radiogenic 3He are only produced through the neutron bombardment of Li and subsequent beta-decay of tritium. We measured Li, U, Th, major and rare-earth element concentrations in whole-rock basalts and mineral separates. These concentrations are used to estimate the ratio of radiogenic helium contributed to the total helium system in our samples. Li concentrations typically range from 6 to 17 ppm, with one outlier of 62 ppm. U contents range from calculations predict that the average radiogenic helium (R/Ra) contributed to the total helium in Black Mountain basalt samples is 0.011. Other noble gas studies have shown

  13. High-pressure apparatus

    NARCIS (Netherlands)

    Schepdael, van L.J.M.; Bartels, P.V.; Berg, van den R.W.

    1999-01-01

    The invention relates to a high-pressure device (1) having a cylindrical high-pressure vessel (3) and prestressing means in order to exert an axial pressure on the vessel. The vessel (3) can have been formed from a number of layers of composite material, such as glass, carbon or aramide fibers which

  14. Polarized emission from CsPbX3 perovskite quantum dots

    Science.gov (United States)

    Wang, Dan; Wu, Dan; Dong, Di; Chen, Wei; Hao, Junjie; Qin, Jing; Xu, Bing; Wang, Kai; Sun, Xiaowei

    2016-06-01

    Compared to organic/inorganic hybrid perovskites, full inorganic perovskite quantum dots (QDs) exhibit higher stability. In this study, full inorganic CsPbX3 (X = Br, I and mixed halide systems Br/I) perovskite QDs have been synthesized and interestingly, these QDs showed highly polarized photoluminescence which is systematically studied for the first time. Furthermore, the polarization of CsPbI3 was as high as 0.36 in hexane and 0.40 as a film. The CsPbX3 perovskite QDs with high polarization properties indicate that they possess great potential for application in new generation displays with wide colour gamut and low power consumption.Compared to organic/inorganic hybrid perovskites, full inorganic perovskite quantum dots (QDs) exhibit higher stability. In this study, full inorganic CsPbX3 (X = Br, I and mixed halide systems Br/I) perovskite QDs have been synthesized and interestingly, these QDs showed highly polarized photoluminescence which is systematically studied for the first time. Furthermore, the polarization of CsPbI3 was as high as 0.36 in hexane and 0.40 as a film. The CsPbX3 perovskite QDs with high polarization properties indicate that they possess great potential for application in new generation displays with wide colour gamut and low power consumption. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr01915c

  15. CH3CO + O2 + M (M = He, N2) Reaction Rate Coefficient Measurements and Implications for the OH Radical Product Yield.

    Science.gov (United States)

    Papadimitriou, Vassileios C; Karafas, Emmanuel S; Gierczak, Tomasz; Burkholder, James B

    2015-07-16

    The gas-phase CH3CO + O2 reaction is known to proceed via a chemical activation mechanism leading to the formation of OH and CH3C(O)OO radicals via bimolecular and termolecular reactive channels, respectively. In this work, rate coefficients, k, for the CH3CO + O2 reaction were measured over a range of temperature (241-373 K) and pressure (0.009-600 Torr) with He and N2 as the bath gas and used to characterize the bi- and ter-molecular reaction channels. Three independent experimental methods (pulsed laser photolysis-laser-induced fluorescence (PLP-LIF), pulsed laser photolysis-cavity ring-down spectroscopy (PLP-CRDS), and a very low-pressure reactor (VLPR)) were used to characterize k(T,M). PLP-LIF was the primary method used to measure k(T,M) in the high-pressure regime under pseudo-first-order conditions. CH3CO was produced by PLP, and LIF was used to monitor the OH radical bimolecular channel reaction product. CRDS, a complementary high-pressure method, measured k(295 K,M) over the pressure range 25-600 Torr (He) by monitoring the temporal CH3CO radical absorption following its production via PLP in the presence of excess O2. The VLPR technique was used in a relative rate mode to measure k(296 K,M) in the low-pressure regime (9-32 mTorr) with CH3CO + Cl2 used as the reference reaction. A kinetic mechanism analysis of the combined kinetic data set yielded a zero pressure limit rate coefficient, kint(T), of (6.4 ± 4) × 10(-14) exp((820 ± 150)/T) cm(3) molecule(-1) s(-1) (with kint(296 K) measured to be (9.94 ± 1.3) × 10(-13) cm(3) molecule(-1) s(-1)), k0(T) = (7.39 ± 0.3) × 10(-30) (T/300)(-2.2±0.3) cm(6) molecule(-2) s(-1), and k∞(T) = (4.88 ± 0.05) × 10(-12) (T/300)(-0.85±0.07) cm(3) molecule(-1) s(-1) with Fc = 0.8 and M = N2. A He/N2 collision efficiency ratio of 0.60 ± 0.05 was determined. The phenomenological kinetic results were used to define the pressure and temperature dependence of the OH radical yield in the CH3CO + O2 reaction. The

  16. Autoionization spectra of He excited by fast (MeV) H/sup +/, He/sup +/, and Li/sup n//sup +/ (N = 1,2,3) ions

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, D.; Arcuni, P.; Bruch, P.; Stoeffler, W.

    1983-01-01

    Autoionization spectra of He following excitation by 1 to 3 MeV H/sup +/, He/sup +/, and Li/sup n//sup +/ (n = 1,2,3) have been measured as a function of observation angle. The (2p/sup 2/)/sup 1/D and (2s2p)/sup 1/P resonances have been examined and a strong dependence on projectile velocities, charge state and observation angle was found. The measurements were performed in a crossed-beam scattering chamber. The target-gas pressure was in the order of 10/sup -4/ Torr. The secondary electrons have been energy analyzed by a 45/sup 0/ parallel-plate analyzer. Results are presented and discussed. (WHK)

  17. Temperature dependence of He(2 3PJ) reactions: Collision-induced mixing and conversion to He2( 3Πg) molecules

    International Nuclear Information System (INIS)

    Zhao, X.; Soletsky, P.A.; Bryan, W.H.; Dunning, F.B.; Walters, G.K.

    1993-01-01

    The rate coefficients for mixing between He(2 3 P J, MJ) levels during collisions with ground-state helium atoms and for conversion of He(2 3 P J ) atoms to He 2 (b 3 Π g ) molecules via three-body reactions in helium gas have been investigated over the temperature range 1.6--300 K. The measured rate coefficients for collisionally induced P-state mixing decrease slowly with decreasing temperature, from (1.8±0.5)x10 -9 cm 3 s -1 at 300 K to (4.5±0.5)x10 -10 cm 3 s -1 at 4.2 K. The rate coefficients for the production of He 2 (b 3 Π g ) molecules via three-body reactions are observed to increase with decreasing temperature and are described by the relation k P congruent(2.5+267T -1 )x10 -32 cm 6 s -1 . This behavior, which is very different from that noted in earlier studies of the conversion of He(2 3 S 1 ) atoms to He 2 (a 3 Σ u + ) molecules through three-body reactions, suggests that the reaction is not thermally activated

  18. Structure and magnetic properties of the 3d transition-metal mono-borides TM–B (TM=Mn, Fe, Co) under pressures

    International Nuclear Information System (INIS)

    Bourourou, Y.; Beldi, L.; Bentria, B.; Gueddouh, A.; Bouhafs, B.

    2014-01-01

    In this paper, spin-polarization and pressure effects on the structural and electronic properties of the 3d transition-metal mono-borides TM–B (TM=Mn, Fe, Co) have been studied by using both local spin-density approximation (LSDA) and generalized gradient approximation (GGA) within the framework of density-functional theory (DFT). At equilibrium, spin-polarization calculations show that MnB and FeB compounds carry magnetic moment. The non-spin-polarization results show that the non-magnetic state is unstable for MnB and FeB compounds, but a stable non-magnetic phase for CoB compound, which is discussed in the framework of the well-known Stoner criterion. The calculated lattice parameters, bulk moduli, their first-pressure derivatives and magnetic moments agree well with experimental and other theoretical results. Significant differences in volume and in bulk modulus were found between the magnetic and non-magnetic case reached 4%, 22%, respectively. The effect of pressure on the crystal structure reflects in a compression of the unit cell volume with a decreasing in the magnetic moment. The density of states of MnB and FeB ferromagnetic compounds are significantly modified under high pressures. The exchange energy decreases with increasing pressure, at approximately V/V 0 =0.6, the exchange energy becomes absent in ferromagnetic compounds causes mirror in upper and lowers half panels. Finally, we notice that spin-polarization and pressure play a crucially important role in determining the electronic and structural properties of 3d transition-metal mono-borides. - Highlights: • Spin polarization and pressure effects on TM–B (TM=Mn, Fe, Co) have been investigated. • The non-spin-polarization results show that the non-magnetic state is stable for CoB. • The magnetic states of MnB and FeB are found more stable than their nonmagnetic states. • We report significant differences between the magnetic and non-magnetic cases. • The density of states of MnB and

  19. Measurement of the Electrical Conductivity of He3 Plasma Induced by Neutron Irradiation

    International Nuclear Information System (INIS)

    Braun, J.; Nygaard, K.

    1966-03-01

    The conductivity of a He plasma created by the inelastic reaction with thermal neutrons: 3 He + n th -> 3 H + p + 0.76 MeV is studied as a function of neutron flux, gas temperature and gas density. Using reported values of the electron mobility the electron density is calculated from experimental conductivity values. Further, by accepting a reasonable value for the mean energy lost in creating one ion-pair, the recombination coefficient is estimated. The measurements performed so far cover temperatures between 300 - 1600 K and densities between 0.25 - 1 times the density at atmospheric pressure and 300 K. The neutron flux is varied between 10 10 - 10 11 n/cm 2 /s. As a sample of results achieved at 1600 K and the lowest density (corresponding to about atmospheric pressure) and the highest neutron flux the following values are obtained for the conductivity, the electron density and the recombination coefficient respectively: σ 0.2 S/m, n e 6x10 11 /cm 3 , α = 2xl0 -10 cm 3 /s. An extrapolation of data obtained shows that the concept of neutron induced conductivity should be attractive for MHD power generation

  20. Thermodynamics of dilute 3He-4He solid solutions with hcp structure

    Science.gov (United States)

    Chishko, K. A.

    2018-02-01

    To interpret the anomalies in heat capacity CV(T) and temperature-dependent pressure P(T) of solid hexagonal close-packed (hcp) 4He we exploit the model of hcp crystalline polytype with specific lattice degrees of freedom and describe the thermodynamics of impurity-free 4He solid as superposition of phononic and polytypic contributions. The hcp-based polytype is a stack of 2D basal atomic monolayers on triangular lattice packed with arbitrary long (up to infinity) spatial period along the hexagonal c axis perpendicular to the basal planes. It is a crystal with perfect ordering along the layers, but without microscopic translational symmetry in perpendicular direction (which remains, nevertheless, the rotational crystallographic axis of third order, so that the polytype can be considered as semidisordered system). Each atom of the hcp polytype has twelve crystallographic neighbors in both first and second coordination spheres at any arbitrary packing order. It is shown that the crystal of such structure behaves as anisotropic elastic medium with specific dispersion law of phonon excitations along c axis. The free energy and the heat capacity consist of two terms: one of them is a normal contribution [with CV(T) ˜ T3] from phonon excitations in an anisotropic lattice of hexagonal symmetry, and another term (an "excessive" heat) is a contribution resulted by packing entropy from quasi-one-dimensional system of 2D basal planes on triangular lattice stacked randomly along c axis without braking the closest pack between neighboring atomic layers. The excessive part of the free energy has been treated within 1D quasi-Ising (lattice gas) model using the transfer matrix approach. This model makes us possible to interpret successfully the thermodynamic anomaly (heat capacity peak in hcp 4He) observed experimentally.

  1. Experimental research of the radiative capture of thermal neutrons in 3He

    International Nuclear Information System (INIS)

    Bystritskij, V.M.; Enik, T.L.; Gerasimov, V.V.; Grebenyuk, V.M.; Kobzev, A.P.; Kublikov, R.V.; Parzhitskij, S.S.; Pavlov, V.N.; Salamatin, A.V.; Shvetsov, V.N.; Slepnev, V.M.; Strelkov, A.V.; Zamyatin, N.I.; Bystritskij, V.M.; Filipowicz, M.; Nesvizhevskij, V.V.; Popov, N.P.; Wozniak, J.

    2006-01-01

    A project of an experiment on measurement of the cross sections of radiative thermal neutron capture by 3 He nuclei with production of one and two γ-quanta (n th + 3 He→α+γ(2γ)) is presented. The interest in studying the processes is dictated by the following factors: a possibility of obtaining information on parameters of the nucleon N-N potential and structure of exchange meson currents; a possibility of verifying the model of the mechanism for nucleon capture by the nucleus 3 He in the low-energy region; necessity to solve some questions existing in astrophysics. The experiment is planned to be carried out on the PF1B beam of the ILL reactor (Grenoble). The target is a hollow cylinder of pure aluminium (diam. 140x80 mm) filled with 3 He and 4 He (background experiment) at the pressure 2 atm. Registration of the γ-quanta is carried out by four BGO crystal (diam. 100x70 mm) detectors. According to the calculations the experiment, with 400-500 h of the PF1B beam running time, will allow cross sections for the above reactions to be measured for the first time with an accuracy of 2-4% (one-quantum process) and 7-10 % (two-quantum process), which quite meets the purposes of the project

  2. A high efficiency bunching system for the TUNL polarized ion source

    International Nuclear Information System (INIS)

    Wender, S.A.

    1981-01-01

    The problem of producing pulsed beams without large beam current losses has been the topic of recent interest particularly in areas where large peak currents are required. In addition, an efficient bunching system will allow the use of pulsed beams when source intensities are limited. The motivation for the development of the authors' high efficiency bunching system arose from their strong interest in neutron physics and the desire to extend their research with experiments requiring polarized neutrons. A common method for the production of polarized neutrons is to bombard a deuterium gas cell with a polarized deuteron beam. The D(→d,n) 3 He reaction has a large cross section and the outgoing neutron has a polarization of approximately 60 % in the energy range between 6 MeV to 16 Mev. Most experiments which involve the detection of neutrons use time-of-flight techniques to determine the neutron energy. An excellent way of providing time-of-flight information is to use pulsed beams. To be useful for time of flight experiments beam pulses must be on the order of a few nanoseconds wide. In addition there must be sufficient time between beam bursts to allow the reaction neutrons to travel from the target to the detector before the next beam burst arrives at the target. For reactions studied at the authors' laboratory, with their flight paths, this time is on the order of 400 ns

  3. High pressure experimental studies on Na3Fe(PO4)(CO3) and Na3Mn(PO4)(CO3): Extensive pressure behaviors of carbonophosphates family

    Science.gov (United States)

    Gao, Jing; Huang, Weifeng; Wu, Xiang; Qin, Shan

    2018-04-01

    Carbon-bearing phases in the Earth's interior have profound implications for the long-term Earth carbon cycle. Here we investigate high-pressure behaviors of carbonophosphates bonshtedtite Na3Fe(PO4)(CO3) and sidorenkite Na3Mn(PO4)(CO3) in diamond anvil cells up to ∼12 GPa at room temperature. Modifications in in situ synchrotron X-ray diffraction patterns and Raman spectra confirm the structural stability of carbonophosphates within the pressure region. Fitting the third-order Birch-Murnaghan equation of state to the volume compression curve, the isothermal bulk modulus parameters are obtained to be K0 = 56(1) GPa, K0' = 3.3(1), V0 = 303.3(3) Å3 for Na3Fe(PO4)(CO3) and K0 = 54(1) GPa, K0' = 3.4(1), V0 = 313.4(2) Å3 for Na3Mn(PO4)(CO3). Crystallographic axes exhibit an elastic anisotropy with a more compressible c-axis relative to the ab-plane. An inverse linear correlation between the K0 value and the ionic radius of M2+ (M = Mg, Fe, Mn) is well determined for carbonophosphates. The pressure-dependence responsiveness of [PO4] and [CO3] in carbonophosphates show a negative relationship to the M2+ radius. We also discussed the effect of [PO4] group on the structural variations and high-pressure behaviors of carbonates. Furthermore, the geochemical properties of carbonophosphates hold implications to diamond genesis.

  4. Simple and efficient method of spin-polarizing a metastable helium beam by diode laser optical pumping

    International Nuclear Information System (INIS)

    Granitza, B.; Salvietti, M.; Torello, E.; Mattera, L.; Sasso, A.

    1995-01-01

    Diode laser optical pumping to produce a highly spin-polarized metastable He beam to be used in a spin-polarized metastable atom deexcitation spectroscopy experiment on magnetized surfaces is described. Efficient pumping of the beam is performed by means of an SDL-6702 distributed Bragg reflector diode laser which yields 50 mW of output power in a single longitudinal mode at 1083 nm, the resonance wavelength for the 2 3 S→2 3 P 0,1,2 (D 0 , D 1 , and D 2 ) transitions of He*. The light is circularly polarized by a quarter-wave plate, allowing easy change of the sense of atomic polarization. The laser frequency can be locked to the atomic transition for several hours by phase-sensitive detection of the saturated absorption signal in a He discharge cell. Any of the three transitions of the triplet system can be pumped with the laser but the maximum level of atomic polarization of 98.5% is found pumping the D 2 line. copyright 1995 American Institute of Physics

  5. Study of the high-pressure helium phase diagram using molecular dynamics

    International Nuclear Information System (INIS)

    Koci, L; Ahuja, R; Belonoshko, A B; Johansson, B

    2007-01-01

    The rich occurrence of helium and hydrogen in space makes their properties highly interesting. By means of molecular dynamics (MD), we have examined two interatomic potentials for 4 He. Both potentials are demonstrated to reproduce high-pressure solid and liquid equation of state (EOS) data. The EOS, solid-solid transitions and melting at high pressures (P) were studied using a two-phase method. The Buckingham potential shows a good agreement with theoretical and experimental EOS, but does not reproduce experimental melting data. The Aziz potential shows a perfect match with theoretical melting data. We conclude that there is a stable body-centred-cubic (bcc) phase for 4 He at temperatures (T) above 340 K and pressures above 22 GPa for the Buckingham potential, whereas no bcc phase is found for the Aziz potential in the applied PT range

  6. Pressure-induced Polarization Reversal in Z-type Hexaferrite Single Crystal

    Science.gov (United States)

    Jeon, Byung-Gu; Chun, Sae Hwan; Kim, Kee Hoon

    2012-02-01

    Multiferroic materials with a gigantic magnetoelectric (ME) coupling at room temperature have been searched for applications to novel devices. Recently, large direct and converse ME effects were realized at room temperature in the so-called Z-type hexaferrite (Ba,Sr)3Co2Fe24O41 single crystals [1,2]. To obtain a new control parameter for realizing a sensitive ME tuning, we studied ME properties of the crystals under uniaxial pressure. Upon applying a tiny uniaxial pressure of about 0.6 GPa, magnetic field-driven electric polarization reversal and anomaly in a M-H loop start to appear at 10 K and gradually disappear at higher temperature above 130 K. By comparing those results with longitudinal magnetostriction at ambient pressure, we propose the pressure-dependent variations of transverse conical spin configuration as well as its domain structure under small magnetic field bias, and point out the possibility of having two different physical origins of the ME coupling in this system. [1] Y. Kitagawa et al., Nat. Mater. 9, 797 (2010) [2] S. H. Chun et al., submitted.

  7. Ferroelectric and magnetic properties in high-pressure synthesized BiFeO3 compound

    International Nuclear Information System (INIS)

    Zhai, L.; Shi, Y.G.; Gao, J.L.; Tang, S.L.; Du, Y.W.

    2011-01-01

    Highlights: → A high-density polycrystalline BiFeO 3 compound was synthesized by high-pressure annealing method. → The sample showed weak ferromagnetic at room temperature, which could be attributed to the lattice distortion induced by the high-pressure annealing. → Irregular domains were observed on the surface of the sample by piezoresponse force microscopy, and a typical hysteresis loop was obtained. - Abstract: High-density polycrystalline BiFeO 3 compound was synthesized by high-pressure annealing. Measurements of crystal structure, magnetic, and ferroelectric properties were made on the sample. It was found that the sample was almost single phase with a distorted R3c structure. The results of the X-ray photoelectron spectra demonstrate that the oxidation state of Fe in the sample is Fe 3+ . The room-temperature field dependence of magnetization for BiFeO 3 exhibits a hysteretic behavior. The observed weak ferromagnetism could be ascribed to the lattice distortion induced by the high-pressure annealing. In addition, the local ferroelectric performance of the sample was studied by piezoresponse force microscopy.

  8. The 3H–3He Charge Radii Difference

    Directory of Open Access Journals (Sweden)

    Myers L. S.

    2016-01-01

    Full Text Available The upcoming E12-14-009 [1] experiment at Jefferson Lab will determine the ratio of the electric form factors for the A=3 mirror nuclei 3He and 3H. The measurement will use a 1.1 GeV electron beam, a special collimator plate to allow for simultaneous optics measurements, and the low-activity tritium target being prepared for Jefferson Lab. By observing the dependence of the form factor ratio as a function of Q2 over 0.05–0.09 GeV2, the dependence of the radii extraction on the shape of the form factors is minimized. As a result, we anticipate the uncertainty of the extracted charge radii difference to be 0.03 fm, a reduction of 70% from the current measurement. Using precise measurements of the 3He charge radius from isotopic shift or μHe measurements [2–4], we can deduce the absolute 3H charge radius. The results will provide a direct comparison to recent calculations of the charge radii.

  9. Hydrogen and helium under high pressure: a case for a classical theory of dense matter

    International Nuclear Information System (INIS)

    Celebonovic, V.

    1989-01-01

    When subject to high pressure, H 2 and 3 He are expected to undergo phase transitions, and to become metallic at a sufficiently high pressure. Using a semiclassical theory of dense matter proposed by Savic and Kasanin (1962/65), calculations of phase transition and metallisation pressure have been performed for these two materials. In hydrogen, metallisation occurs at 3.0±0.2 Mbar, while for helium the corresponding value is 106±1 Mbar. A phase transition occurs in helium at 10.0±0.4 Mbar. These values are close to the results obtainable by more rigorous methods. Possibilities of experimental verification of the calculations are briefly discussed. 38 refs

  10. Hydrogen and helium under high pressure: a case for a classical theory of dense matter

    Energy Technology Data Exchange (ETDEWEB)

    Celebonovic, V. (Belgrade Univ. (Yugoslavia). Inst. za Fiziku)

    1989-06-01

    When subject to high pressure, H{sub 2} and {sup 3}He are expected to undergo phase transitions, and to become metallic at a sufficiently high pressure. Using a semiclassical theory of dense matter proposed by Savic and Kasanin (1962/65), calculations of phase transition and metallisation pressure have been performed for these two materials. In hydrogen, metallisation occurs at 3.0{plus minus}0.2 Mbar, while for helium the corresponding value is 106{plus minus}1 Mbar. A phase transition occurs in helium at 10.0{plus minus}0.4 Mbar. These values are close to the results obtainable by more rigorous methods. Possibilities of experimental verification of the calculations are briefly discussed. 38 refs.

  11. Study of the 6Li + p → 3He + 4He reaction in inverse kinematics

    International Nuclear Information System (INIS)

    Betsou, C.; Pakou, A.; Aslanoglou, X.; Nicolis, N.G.; Sgouros, O.; Soukeras, V.; Cappuzzello, F.; Acosta, L.; Agodi, C.; Carbone, D.; Cavallaro, M.; Di Pietro, A.; Fernandez-Garcia, J.P.; Figuera, P.; Fisichella, M.; Foti, A.; Keeley, N.; Marquinez-Duran, G.; Martel, I.; Mazzocco, M.; Strano, E.; Torresi, D.; Pierroutsakou, D.; Rusek, K.; Stiliaris, E.

    2015-01-01

    Angular distribution measurements were performed for the 6 Li + p → 3 He + 4 He reaction in inverse kinematics at incident energies of 2.7, 3.3, 4.2 and 4.8 MeV/u. The detection of both recoils ( 3 He and 4 He) over the laboratory angle range θ lab = 16 circle to 34 circle allowed the determination of the angular distribution over a wide angular range in the center-of-mass frame (θ c.m. ∝ 40 circle to 140 circle ). The results clarify inconsistencies between existing data sets and are consistent with compound nucleus model calculations. (orig.)

  12. 3He/4He ratio, noble gas abundance and K-Ar dating of diamonds - an attempt to search for the records of early terrestrial history

    International Nuclear Information System (INIS)

    Ozima, M.; Zashu, S.; Nitoh, O.

    1983-01-01

    The 3 He/ 4 He ratios measured in 27 Southern Africa diamond stones, four from Premier Mine and the rest of unidentified origin, range from 4.2 x 10 -8 to 3.2 x 10 -4 , with three stones above 1 x 10 -4 . We conclude that the initial helium isotopic ratio ( 3 He/ 4 He) 0 in the earth was significantly higher than that of the planetary helium-A ( 3 He/ 4 He = 1.42 x 10 -4 ), but close to the solar helium ( 3 He/ 4 He = approx. 4 x 10 -4 ). The apparent K-Ar ages for the twelve diamonds of unidentified origin show enormously old age, indicating excess argon-40. 3 He/ 4 He evolution in diamonds suggests that the diamonds with the high 3 He/ 4 He ratio (> 2 x 10 -4 ) may be as old as the earth. Noble gas elemental abundance in the diamonds relative to the air noble gas abundance shows monotonic decrease with a decreasing mass number. This paper discusses the implications of these observations on the early solar system and the origin of diamonds. (author)

  13. Electric dipole moment of 3He

    International Nuclear Information System (INIS)

    Avishai, Y.; Fabre de la Ripelle, M.

    1987-01-01

    The contribution of CP violating nucleon-nucleon interaction to the electric dipole moment of 3 He is evaluated following a recent proposal for its experimental detection. Two models of CP violating interactions are used, namely, the Kobayashi-Maskawa mechanism and the occurrence of the Θ term in the QCD lagrangian. These CP violating interactions are combined with realistic strong nucleon-nucleon interactions to induce a CP forbidden component of the 3 He wave function. The matrix element of the electric dipole operator is then evaluated between CP allowed and CP forbidden components yielding the observable electric dipole moment. Using the parameters emerging from the penguin terms in the Kobaysashi-Maskawa model we obtain a result much larger than the electric dipole moment of the neutron in the same model. On the other hand, no enhancement is found for the Θ-term mechanism. A possible explanation for this difference is discussed. Numerical estimates can be given only in the Kobayashi-Maskawa model, giving d( 3 He) ≅ 10 30 e . cm. In the second mechanism, the estimate give d ( 3 He) ≅ 10 16 anti Θ. (orig.)

  14. Superfluidity in two-dimensions. A thermal conductivity study of 4He and 3He- 4He mixture films

    International Nuclear Information System (INIS)

    Finotello, D.

    1992-01-01

    We review measurement of the thermal transport of 4 He films and 3 He- 4 He mixture films near the superfluid transition. These measurements were performed on helium films of thickness ranging from 12 to 156 A and mixture films with 3 He concentration up to 2%. The superfluid transition temperature for these films ranged from 1.2 to 2.2. K. We discuss universal features of the data as well as the behavior of the ratio of the vortex diffusion constant to vortex core-parameter, the sharpness of the transition and the superfluid transition temperature as a function of thickness and concentration. We also describe new experiments that will contribute to a better understanding of the observed behavior (Author)

  15. In Situ Atmospheric Pressure Measurements in the Martian Southern Polar Region: Mars Volatiles and Climate Surveyor Meteorology Package on the Mars Polar Lander

    Science.gov (United States)

    Harri, A.-M.; Polkko, J.; Siili, T.; Crisp, D.

    1998-01-01

    Pressure observations are crucial for the success of the Mars Volatiles and Climate Surveyor (MVACS) Meteorology (MET) package onboard the Mars Polar Lander (MPL), due for launch early next year. The spacecraft is expected to land in December 1999 (L(sub s) = 256 degrees) at a high southern latitude (74 degrees - 78 degrees S). The nominal period of operation is 90 sols but may last up to 210 sols. The MVACS/MET experiment will provide the first in situ observations of atmospheric pressure, temperature, wind, and humidity in the southern hemisphere of Mars and in the polar regions. The martian atmosphere goes through a large-scale atmospheric pressure cycle due to the annual condensation/sublimation of the atmospheric CO2. Pressure also exhibits short period variations associated with dust storms, tides, and other atmospheric events. A series of pressure measurements can hence provide us with information on the large-scale state and dynamics of the atmosphere, including the CO2 and dust cycles as well as local weather phenomena. The measurements can also shed light on the shorter time scale phenomena (e.g., passage of dust devils) and hence be important in contributing to our understanding of mixing and transport of heat, dust, and water vapor.

  16. Application of {sup 14}N({sup 3}He,{sup 4}He){sup 13}N nuclear reaction to nitrogen profiling

    Energy Technology Data Exchange (ETDEWEB)

    Wielunski, L.S. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), Lindfield, NSW (Australia). Div. of Applied Physics

    1996-12-31

    In this paper the {sup 14}N({sup 3}He,{sup 4}He){sup 1`}3N reaction is proposed for nitrogen profiling in metals and other materials. The beam energy is chosen to be 4.65 MeV in order to use the high cross section. Two types of particle filtering are used: a 25 {mu}m thick mylar in front of the detector to avoid backscattered particle pileup and reduced detector bias voltage to avoid full energy detection of high energy protons produced by competing reactions. The depth resolution is about 150-200 nm and the sensitivity is better than for the {sup 14}N(d,{sup 4}He){sup 12}C reaction. The low level of neutron radiation background allows use of this reaction in accelerator laboratories without radiation shielding. 11 refs., 5 figs.

  17. Application of {sup 14}N({sup 3}He,{sup 4}He){sup 13}N nuclear reaction to nitrogen profiling

    Energy Technology Data Exchange (ETDEWEB)

    Wielunski, L S [Commonwealth Scientific and Industrial Research Organisation (CSIRO), Lindfield, NSW (Australia). Div. of Applied Physics

    1997-12-31

    In this paper the {sup 14}N({sup 3}He,{sup 4}He){sup 1`}3N reaction is proposed for nitrogen profiling in metals and other materials. The beam energy is chosen to be 4.65 MeV in order to use the high cross section. Two types of particle filtering are used: a 25 {mu}m thick mylar in front of the detector to avoid backscattered particle pileup and reduced detector bias voltage to avoid full energy detection of high energy protons produced by competing reactions. The depth resolution is about 150-200 nm and the sensitivity is better than for the {sup 14}N(d,{sup 4}He){sup 12}C reaction. The low level of neutron radiation background allows use of this reaction in accelerator laboratories without radiation shielding. 11 refs., 5 figs.

  18. Specific features of kinetics of He3-He4 solid solution transformations at superlow temperatures

    International Nuclear Information System (INIS)

    Mikheev, V.A.; Majdanov, V.A.; Mikhin, N.P.

    1986-01-01

    The NMR data on the phase transition kinetics of 3 He- 4 He solid solutions at T=100 mK are considered. Studied are solid helium samples of a molecular volume of 20.55 cm 2 /mol with a 3 He content of 0.54 %. An unusually long phase transition time is found which is dependent on the prehistory of sample. The spin diffusion of 3 He in the transformated solution concentrated phase is found to be of a quasi-one-dimensional nature with the diffusion coefficient value typical of liquid

  19. Specific features of concentrated phase under decomposition of weak solid /sup 3/He-/sup 4/He solution

    Energy Technology Data Exchange (ETDEWEB)

    Mikheev, V A; Majdamov, V A; Kal' noj, S E; Omelaenko, N I

    1988-06-01

    The decomposition of solid /sup 3/He-/sup 4/He solutuions is studied on the samples 0.54% /sup 3/He(V=20.55 cm/sup 3//mole) and 0.60% /sup 4/He (V=24.04-24.93 cm/sup 3//mole) using pulse NMR method. At T=100 mK the decomposition of a weak solution proceeds more than for 30 h, the decomposition rate and temperature being dependent on the sample prehistory. In the concentrated phase of the decomposed weak solution the spin diffraction of /sup 3/He is of the quasi-one-dimensional character with the diffusion coefficient D /similar to/ 10/sup -5/ cm/sup 2//sec typical of liquid /sup 3/He and exceeding that bulk solid /sup 3/He by two orders of magnitude. The longitudinal relaxation time in the quasi-one-dimensional phase (/similar to/ 1 sec) is characteristic of the solid state and coinsides with data for bulk /sup 3/He. The temperature behaviour of magnetization in the quasi-one-dimensional phase is well described by the Curie law.

  20. Three-critical phenomena in the He3-He4 mixture

    International Nuclear Information System (INIS)

    Carvalho Filho, C.A.A. de.

    1976-07-01

    A review of the phenomenology of tricritical behaviour in He 3 -He 4 mixtures is made. Starting from a model proposed by Blume, Emery and Griffiths the tricritical transition is investigated by means of the Renormalization Group making use of the Callan-Symanzik equation and usual perturbative methods of Relativistic Quantum Field Theory. Mean-field tricritical exponents and logarithmic corrections are found in a sup(n) unified context. The structure of scaling laws is also studied. (author) [pt

  1. 3He functions in tokamak-pumped laser systems

    International Nuclear Information System (INIS)

    Jassby, D.L.

    1986-10-01

    3 He placed in an annular cell around a tokamak fusion generator can convert moderated fusion neutrons to energetic ions by the 3 He(n,p)T reaction, and thereby excite gaseous lasants mixed with the 3 He while simultaneously breeding tritium. The total 3 He inventory is about 4 kg for large tokamak devices. Special configurations of toroidal-field magnets, neutron moderators and beryllium reflectors are required to permit nearly uniform neutron current into the laser cell with minimal attenuation. The annular laser radiation can be combined into a single output beam at the top of the tokamak

  2. Thermal transport properties in dilute 3He-4He mixtures near the superfluid transition

    International Nuclear Information System (INIS)

    Tuttle, J.G.

    1991-01-01

    The author describes measurements of various transport properties of dilute liquid 3 He- 4 He mixtures in two different sample cells. One cell was designed to measure the temperature drop ΔT across a fluid layer due to an applied heat flux Q, and the other allowed measurement of both ΔT and ΔX, the molar concentration drop. He studied the anomalous boundary resistance, ΔR b , in superfluid 4 He near T λ for Q between 4 and 100μW/cm 2 . He presents results for both the weakly divergent and the heat dependent, more strongly divergent contributions. He compares his data with those of Duncan and Ahlers and with theoretical predictions by Frank and Dohm. He also presents similar R b data for a mixture with X = 2.5 x 10 -6 . He determined the relaxation time τ for transients observed during thermal conductivity κ eff and thermal diffusion k T * measurements in superfluid mixtures between 1.7K and T λ with X ranging from 10 -6 to 5 x 10 -2 . He compares these results, taken with a fluid layer thickness h = 1.81 mm, with theoretical predictions and with earlier data for h = 1.47 mm. He shows the mass diffusion coefficient D computed both from τ and from κ eff data for 0.001 λ , and he compares the results of these two different determinations. In addition, he presents the 3 He-roton scattering cross section calculated using D results. In the normal phase he measured the thermal diffusion ratio k T and the thermal conductivity κ for 0.009 ≤ X ≤ 0.05 near T λ , and he compares these results with predictions by Dohm and Folk

  3. Ultra-high resolution spectroscopy of the He doubly excited states

    International Nuclear Information System (INIS)

    Bozek, J.D.; Schlachter, A.S.; Kaindl, G.; Schulz, K.

    1995-11-01

    Photoionization spectra of the doubly-excited states of He were measured using beamline 9.0.1 at the Advanced Light Source. The beamline utilizes a 4.5 m long 8 cm period undulator as its source together with a spherical grating monochromator to provide an extremely bright source of photons in the range of 20 - 300 eV. A resolving power (E/ΔE) of 64,000 was obtained from the 1 MeV FWEM (2p,3d) doubly excited state resonance of He at 64.12 eV. The high brightness of the source and the very high quality optical elements of the beamline were all essential for achieving such a high resolution. The beamline components and operation are described and spectra of the double excitation resonances of He presented

  4. Meaurement of the target single-spin asymmetry in quasi-elastic region from the reaction {sup 3}He{up_arrow}(e,e')

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yawei [Rutgers

    2013-10-01

    A measurement of the inclusive target single-spin asymmetry has been performed using the quasi-elastic {sup 3}He{up_arrow}(e,e') reaction with a vertically polarized {sup 3}He target at Q{sup 2} values of 0.13, 0.46 and 0.97 GeV{sup 2}. This asymmetry vanishes under the one photon exchange assumption. But the interference between two-photon exchange and one-photon exchange gives rise to an imaginary amplitude, so that a non-zero A{sub y} is allowed. The experiment, conducted in Hall A of Jefferson Laboratory in 2009, used two independent spectrometers to simultaneously measure the target single-spin asymmetry. Using the effective polarization approximation, the neutron single-spin asymmetries were extracted from the measured {sup 3}He asymmetries. The measurement is to establish a non-vanishing A{sub y}. Non-zero asymmetries were observed at all Q{sup 2} points, and the overall precision is an order of magnitude improved over the existing proton data. The data provide new constraints on Generalized Parton Distribution (GPD) models and new information on the dynamics of the two-photon exchange process.

  5. Exchange currents in low-energy nucleon capture by 3He

    International Nuclear Information System (INIS)

    Wervelman, Rob.

    1991-01-01

    The studies described in this thesis concern absolute cross-section measurements of the radiative neutron capture reactions 3 He (n,γ) 4 He and 3 He(n,γγ) 4 He, and are complements with shell-model calculations on the radiative thermal neutron capture reaction by 3 He and on the weak 3 He(p,e + ν e ) 4 He reaction. The experiments have been performed at two neutron energies, with sub-thermal neutrons where s-wave capture is dominant, and with a quasi-monochromatic 24.5 keV neutron beam (p-wave capture). It has been found that the thermal neutron capture cross section of 3 He is 55±3 μb. Measured at 24.5 keV-neutron energy, the radiative capture cross section for p-wave neutrons turned out to be 9.1±0.8 μb. A measurement on the double-photon reaction 3 He(n th ,γγ) has yielded a cross-section value of 30±80 μb. In the theoretical part of the work a standard model of nuclear weak and electromagnetic interaction currents, consisting of a one-body impulse approximation and a two-body meson-exchange current part, has been applied to the process of nucleon capture by 3 He. Within the framework of a (0+2) (h/2π)ω shell-model calculation, using Sussex matrix elements for the 3 He and 4 He ground state wave functions, the empirical radiative cross sections for thermal neutrons of 3 He could be reproduced with satisfactory agreement. The total MEC correction to the radiative thermal neutron capture cross section is rather small because large cancellations occur between the various contributions. In the 3 He(p,e + ν e ) 4 He reaction meson-exchange contributions enlarge the astrophysical S-factor by more than a factor two. The matrix element ratio of the weak 3 He+p and the electromagnetic 3 He+n reaction is calculated to be (4.3±0.6)g A C 0 . This ratio has been found to be fairly insensitive to the percentage D-state admixtures in the 3 He and 4 He ground state wave functions. (author). 129 refs.; 24 figs.; 5 tabs

  6. The (3He,t) and (d,2He)reactions at intermediate energies

    International Nuclear Information System (INIS)

    Brockstedt, A.

    1987-09-01

    The ( 3 He,t) reaction has been studied at 0.6-2.3 GeV at small scattering angles, 0-7 degrees, on various nuclei ( 12 C, 13 C, 26 Mg, 40 Ca, 48 Ca, 54 Fe, 90 Zr, 159 Tb, 208 Pb) including a proton target. The reaction is a single-step reaction and selects the spin-isospin channel. Angular distributions for low-lying states in 12 N are well described by DWIA calculations. From 13 C to 13 N transitions the ratio J στ /J τ , at momentum transfer, q, close to zero, is derived. The ratio remains roughly constant in the region 300 - 700 MeV/nucleon. The position of the quasi-free peak is shifted compared with free nucleon-nucleon scattering. The shift is towards higher excitation energies at q approx 1.4 fm -1 , and towards lower excitation energies at q approx 2.5 fm -1 . The p( 3 He,t)Δ ++ reaction is analysed as one-pion exchange and the ( 3 He,t) form factor is extracted. The shape and position of the Δ resonance seem to be independent of target mass for the targets studied. Compared with the p to Δ ++ transition the position is shifted towards lower excitation energy in nuclei. The (d,2p[ 1 S 0 ]) reaction, with the two protons in an 1 S 0 state labelled 2 He, is studied at 0.65 and 2.0 GeV at small angles, 0-4 degrees, on some of the targets used in the ( 3 He,t) experiment (p, 12 C, 40 Ca, 54 Fe). This reaction is also a one-step reaction that can be used for studies of spin-isospin excitations. Cross sections and tensor analysing powers are determined for the p(d, 2 He)n reaction. These results are compared with PWIA calculations. The Δ resonance in carbon is also here shifted down in excitation energy compared with the proton target. (author)

  7. A miniature adsorption3HE refrigerator

    International Nuclear Information System (INIS)

    Duband, L.; Ravex, A.; Lange, A.

    1991-01-01

    A self-contained, recyclable laboratory 3 He refrigerator has been developed. The refrigerator is very compact, portable and is designed to be safe and reliable. The unit can easily be installed on the cold plate of a superfluid 4 He cryostat. Once bolted on the cold plate, operation of the refrigerator is controlled by a single heater. In this new design the refrigerator has a cylindrical geometry. The adsorption pump is placed above the condensation point to prevent convection during the condensation phase and to improve the pumping speed. The inhibition of convection reduces the load on the 4 He bath and increases the condensation efficiency. This refrigeration technique has great potential for space applications. The absence of moving parts makes the system reliable and vibration free. Its simplicity and the absence of external components facilitate its integration on a cryostat. In fact, a rocket-borne 3 He refrigerator has already been successfully flown and has demonstrated the feasibility of this method

  8. Primary populations of metastable antiprotonic $^{4}He$ and $^{3}He$ atoms

    CERN Document Server

    Hori, Masaki; Hayano, R S; Ishikawa, T; Sakuguchi, J; Tasaki, T; Widmann, E; Yamaguchi, H; Torii, H A; Juhász, B; Horváth, D; Yamazaki, T

    2002-01-01

    Initial population distributions of metastable antiprotonic **4He and **3He atoms over principal and angular momentum quantum numbers were investigated using laser spectroscopy. The total fractions of antiprotons captured into the metastable states of the atoms were deduced. Cascade calculations were performed using the measure populations to reproduce the delayed annihilation time spectrum. Results showed agreement between the simulated and measured spectra. (Edited abstract) 30 Refs.

  9. Pressure drop in two-phase He I natural circulation loop at low vapour quality

    International Nuclear Information System (INIS)

    Baudouy, B.

    2003-01-01

    Steady state pressure drop in a two-phase He I natural circulation loop has been measured at atmospheric pressure. Results are obtained up to 0.2 exit vapor quality for a 14-mm diameter copper tube heated over a length of 1.2 m. Pressure drop assessment, done with the momentum balance equation including subcooling, reveals that the homogeneous model and Friedel's friction multiplier associated with Huq and Loth's void fraction correlations predict data within 15%. (author)

  10. Effects of {Delta}-isobar degrees of freedom on the reactions {sup 3}He(n,{gamma}){sup 4}He and {sup 3}He(p,e{sup +}{nu}{sub e}){sup 4}He at low-energy

    Energy Technology Data Exchange (ETDEWEB)

    Schiavilla, R.

    1991-12-31

    The cross sections of the radiative {sup 3}He(n,{gamma}){sup 4}He and weak {sup 3}He(p,e{sup +}{nu}{sub e}){sup 4}He capture reactions at thermal neutron and keV proton energies have been calculated with the Variational Monte Carlo method. The ground state and low-energy continuum wave functions have been determined variationally from a realistic Hamiltonian, and include both nucleon and {Delta}-isobar degrees of freedom. The electroweak transition operator contains one- and two-body components in the N + {Delta} Hilbert space.

  11. Effects of. Delta. -isobar degrees of freedom on the reactions sup 3 He(n,. gamma. ) sup 4 He and sup 3 He(p,e sup +. nu. sub e ) sup 4 He at low-energy

    Energy Technology Data Exchange (ETDEWEB)

    Schiavilla, R.

    1991-01-01

    The cross sections of the radiative {sup 3}He(n,{gamma}){sup 4}He and weak {sup 3}He(p,e{sup +}{nu}{sub e}){sup 4}He capture reactions at thermal neutron and keV proton energies have been calculated with the Variational Monte Carlo method. The ground state and low-energy continuum wave functions have been determined variationally from a realistic Hamiltonian, and include both nucleon and {Delta}-isobar degrees of freedom. The electroweak transition operator contains one- and two-body components in the N + {Delta} Hilbert space.

  12. Geometrical aspects of reaction cross sections for 3He, 4He and 12C projectiles

    International Nuclear Information System (INIS)

    Ingemarsson, A.; Lantz, M.

    2003-04-01

    A black-disc model combined with accurate matter densities has been used for an investigation of reaction cross sections for 3 He, 4 He and 12 C projectiles. A simple relation is derived between the energy dependence of the reaction cross sections and the strength of the nucleon-nucleon interaction. A comparison is also made of the reaction cross sections for 3 He and 4 He for six different nuclei 12 C, 16 O, 40 Ca, 58,60 Ni and 208 Pb

  13. Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. II. Temperature and pressure effects.

    Science.gov (United States)

    Åsberg, Dennis; Samuelsson, Jörgen; Leśko, Marek; Cavazzini, Alberto; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2015-07-03

    The importance of the generated temperature and pressure gradients in ultra-high-pressure liquid chromatography (UHPLC) are investigated and compared to high-pressure liquid chromatography (HPLC). The drug Omeprazole, together with three other model compounds (with different chemical characteristics, namely uncharged, positively and negatively charged) were used. Calculations of the complete temperature profile in the column at UHPLC conditions showed, in our experiments, a temperature difference between the inlet and outlet of 16 °C and a difference of 2 °C between the column center and the wall. Through van't Hoff plots, this information was used to single out the decrease in retention factor (k) solely due to the temperature gradient. The uncharged solute was least affected by temperature with a decrease in k of about 5% while for charged solutes the effect was more pronounced, with k decreases up to 14%. A pressure increase of 500 bar gave roughly 5% increase in k for the uncharged solute, while omeprazole and the other two charged solutes gave about 25, 20 and 15% increases in k, respectively. The stochastic model of chromatography was applied to estimate the dependence of the average number of adsorption/desorption events (n) and the average time spent by a molecule in the stationary phase (τs) on temperature and pressure on peak shape for the tailing, basic solute. Increasing the temperature yielded an increase in n and decrease in τs which resulted in less skew at high temperatures. With increasing pressure, the stochastic modeling gave interesting results for the basic solute showing that the skew of the peak increased with pressure. The conclusion is that pressure effects are more pronounced for both retention and peak shape than the temperature effects for the polar or charged compounds in our study. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Optimizing moderation of He-3 neutron detectors for shielded fission sources

    Energy Technology Data Exchange (ETDEWEB)

    Rees, Lawrence B., E-mail: Lawrence_Rees@byu.edu [Department of Physics and Astronomy, Brigham Young University, Provo, UT 84602 (United States); Czirr, J. Bart, E-mail: czirr@juno.com [Department of Physics and Astronomy, Brigham Young University, Provo, UT 84602 (United States)

    2012-11-01

    The response of a {sup 3}He neutron detector is highly dependent on the amount of moderator incorporated into the detector system. If there is too little moderation, neutrons will not react with the {sup 3}He. If there is too much moderation, neutrons will not reach the {sup 3}He. In applications for portal or border monitors where {sup 3}He detectors are used to interdict illicit importation of plutonium, the fission source is always shielded to some extent. Since the energy distribution of neutrons emitted from the source depends on the amount and type of shielding present, the optimum placement of moderating material around {sup 3}He tubes is a function of shielding. In this paper, we use Monte Carlo techniques to model the response of {sup 3}He tubes placed in polyethylene boxes for moderation. To model the shielded fission neutron source, we use a point {sup 252}Cf source placed in the center of polyethylene spheres of varying radius. Detector efficiency as a function of box geometry and shielding is explored. We find that increasing the amount of moderator behind and to the sides of the detector generally improves the detector response, but that incremental benefits are minimal if the thickness of the polyethylene moderator is greater than about 5-7 cm. The thickness of the moderator in front of the {sup 3}He tubes, however, is very important. For bare sources, about 4-5 cm of moderator is optimum, but as the shielding increases, the optimum thickness of this moderator decreases to 0.5-1 cm. Similar conclusions can be applied to polyethylene boxes employing two {sup 3}He tubes. Two-tube boxes with front moderators of non-uniform thickness may be useful for detecting neutrons over a wide energy range.

  15. High-Pressure Synthesis and Study of NO+NO3− and NO2+NO3− Ionic Solids

    Directory of Open Access Journals (Sweden)

    A. Yu. Kuznetsov

    2009-01-01

    Full Text Available Nitrosonium-nitrate NO+NO3− and dinitrogen pentoxide NO2+NO3− ionic crystals were synthesized by laser heating of a condensed oxygen-rich O2-N2 mixture compressed to different pressures, up to 40 GPa, in a diamond anvil cell (DAC. High-pressure/high-temperature Raman and X-ray diffraction studies of synthesized samples disclosed a transformation of NO+NO3− compound to NO2+NO3− crystal at temperatures above ambient and pressures below 9 GPa. High-pressure experiments revealed previously unreported bands in Raman spectra of NO+NO3− and NO2+NO3− ionic crystals. Structural properties of both ionic compounds are analyzed. Obtained experimental results support a hypothesis of a rotational disorder of NO+ complexes in NO+NO3− and indicate a rotational disorder of ionic complexes in NO2+NO3− solid.

  16. Search for a spin-dependent short-range force between nucleons with a 3He/129Xe clock-comparison experiment

    International Nuclear Information System (INIS)

    Tullney, Kathlynne

    2014-01-01

    Xe then correspond to ω He = γ He . B 0 = 11.4 Hz and ω Xe = γ Xe . B 0 = 4.7 Hz. By means of the weighted frequency difference Δω = ω He - (γ He /γ Xe ) . ω Xe , magnetic field drifts can be eliminated (Zeeman-term). Thus, the co-magnetometer is only sensitive to non-magnetic interactions. Based on the long spin coherence times of several hours, frequency shifts due to non-magnetic interactions in the order of a few nHz can be measured. The general idea of this experiment was to place an unpolarized matter close to the spin polarized samples, which is then removed to a distant position or vice versa. If the spin-dependent short-range interaction exists, the unpolarized matter causes a shift in the spin precession frequencies of 3 He and 129 Xe for the unpolarized matter close to the polarized gases. For 3 He as well as for 129 Xe this frequency shift essentially is stemming from the coupling of the axion to the spin of the valence neutron. Hence it is approximately equal for 3 He and 129 Xe and therefore does not drop out in the weighted frequency difference. Due to the high sensitivity of the co-magnetometer, the upper limit of this frequency shift could be determined to be 7.1 nHz. With this value, an upper limit of the scalar-pseudoscalar coupling of the axion to the spin of a bound neutron could be deduced within the axion mass window. For axion masses between 2 μeV and 500 μeV, the laboratory upper bounds were improved by up to 4 orders of magnitude.

  17. Distorted spin dependent spectral function of {sup 3}He and semi-inclusive deep inelastic scattering processes

    Energy Technology Data Exchange (ETDEWEB)

    Kaptari, Leonya P. [University of Perugia (Italy); INFN-Perugia (Italy); Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Joint Inst. for Nuclear Research, Dubna (Russia); Del Dotto, Alessio [University of Rome, Rome (Italy); INFN-Roma (Italy); Pace, Emanuele [University of Rome (Italy); INFN-Tor Vergata (Italy); Salme, Giovanni [INFN-Roma (Italy); Scopetta, Sergio [University of Perugia (Italy); INFN-Perugia (Italy)

    2014-03-01

    The spin dependent spectral function, relevant to describe polarized electron scattering off polarized {sup 3}He, is studied, within the Plane Wave Impulse Approximation and taking into account final state interaction effects (FSI). In particular, the case of semi-inclusive deep inelastic scattering (SiDIS) is considered, evaluating the FSI of the hadronizing quark with the nuclear remnants. It is shown that particular kinematical regions can be selected to minimize the latter effects, so that parton distributions in the neutron can be accessed. On the other side, in the regions where FSI dominates, the considered reactions can elucidate the mechanism of hadronization of quarks during the propagation in the nuclear medium. It is shown that the obtained spin dependent spectral function can be directly applied to investigate the SiDIS reaction e-vector + {sup 3}He-vector to h+X, where the hadron h originates from the current fragmentation. Experiments of this type are being performed at JLab to extract neutron transverse momentum dependent parton distributions. As a case study, a different SiDIS process, with detection of slow (A-1) systems in the final state, is considered in more details, in order to establish when nuclear structure effects and FSI can be distinguished from elementary reactions on quasi-free nucleons. It is argued that, by a proper choice of kinematics, the origin of nuclear effects in polarized DIS phenomena and the details of the interaction between the hadronizing quark and the nuclear medium can be investigated at a level which is not reachable in inclusive deep inelastic scattering.

  18. High-power laser diodes with high polarization purity

    Science.gov (United States)

    Rosenkrantz, Etai; Yanson, Dan; Peleg, Ophir; Blonder, Moshe; Rappaport, Noam; Klumel, Genady

    2017-02-01

    Fiber-coupled laser diode modules employ power scaling of single emitters for fiber laser pumping. To this end, techniques such as geometrical, spectral and polarization beam combining (PBC) are used. For PBC, linear polarization with high degree of purity is important, as any non-perfectly polarized light leads to losses and heating. Furthermore, PBC is typically performed in a collimated portion of the beams, which also cancels the angular dependence of the PBC element, e.g., beam-splitter. However, we discovered that single emitters have variable degrees of polarization, which depends both on the operating current and far-field divergence. We present data to show angle-resolved polarization measurements that correlate with the ignition of high-order modes in the slow-axis emission of the emitter. We demonstrate that the ultimate laser brightness includes not only the standard parameters such as power, emitting area and beam divergence, but also the degree of polarization (DoP), which is a strong function of the latter. Improved slow-axis divergence, therefore, contributes not only to high brightness but also high beam combining efficiency through polarization.

  19. High precision neutron polarization for PERC

    International Nuclear Information System (INIS)

    Klauser, C.

    2013-01-01

    The decay of the free neutron into a proton, an electron and an anti-electron neutrino offers a simple system to study the semi-leptonic weak decay. High precision measurements of angular correlation coefficients of this decay provide the opportunity to test the standard model on the low energy frontier. The Proton Electron Radiation Channel PERC is part of a new generation of expriments pushing the accuracy of such an angular correlation coefficient measurement towards 10 -4 . Past experiments have been limited to an accuracy of 10 -3 with uncertainties on the neutron polarization as one of the leading systematic errors. This thesis focuses on the development of a stable, highly precise neutron polarization for a large, divergent cold neutron beam. A diagnostic tool that provides polarization higher than 99.99 % and analyzes with an accuracy of 10 -4 , the Opaque Test Bench, is presented and validated. It consists of two highly opaque polarized helium cells. The Opaque Test Bench reveals depolarizing effects in polarizing supermirrors commonly used for polarization in neutron decay experiments. These effects are investigated in detail. They are due to imperfect lateral magnetization in supermirror layers and can be minimized by significantly increased magnetizing fields and low incidence angle and supermirror factor m. A subsequent test in the crossed (X-SM) geometry demonstrated polarizations up to 99.97% from supermirrors only, improving neutron polarization with supermirrors by an order of magnitude. The thesis also discusses other neutron optical components of the PERC beamline: Monte-Carlo simulations of the beamline under consideration of the primary guide are carried out. In addition, calculation shows that PERC would statistically profit from an installation at the European Spallation source. Furthermore, beamline components were tested. A radio-frequency spin flipper was confirmed to work with an efficiency higher than 0.9999. (author) [de

  20. Low-temperature H2-4He and H2-3He targets for operation on an electron beam

    International Nuclear Information System (INIS)

    Gol'dshtejn, V.A.; Lubyanyj, V.V.

    1981-01-01

    Structures and basic characteristics of H 2 - 4 He and H 2 - 3 He low temperature targets are given. Technique of 3 He target filling is described. Initial target cooling up to liquid 4 He temperature and its filling up take near approximately 1 h, at that 4 He flow rate equals 15 l. Repeated filling up of 4 He takes 20 min, and target filling up with 3 He - 10-15 min. Good thermal insulation of a cryostat and targets permits the 4 He target to be operated with an electron beam of a mean current of up to 0.5 μA without filling up 4 He for 70 h. At that flow rate of liquid 4 He amounts to 0.2 l/h, and liquid hydrogen - 0.04 l/h. It is concluded that H 2 - 4 He and H 2 - 3 He targets are reliable and simple in operation and permit to work with accelerated particle beams of intensity corresponding to power release >= 0.5 W without corrections for density change [ru

  1. Brillouin scattering at high pressures

    International Nuclear Information System (INIS)

    Grimsditch, M.; Polian, A.

    1988-02-01

    Technical advances which have made Brillouin scattering a useful tool in high pressure diamond anvil cell (DAC) studies, viz. multipassing and tandem operation of Fabry-Perot interferometers, are reviewed. Experimental aspects, such as allowed scattering geometries, are outlined and the data analysis required to transform Brillouin spectra into sound velocities and elastic constants is presented. Experimental results on H 2 , N 2 , Ar, and He are presented, and the close relationship between the Brillouin scattering results and equations of state is highlighted

  2. High energy polarized electron beams

    International Nuclear Information System (INIS)

    Rossmanith, R.

    1987-01-01

    In nearly all high energy electron storage rings the effect of beam polarization by synchrotron radiation has been measured. The buildup time for polarization in storage rings is of the order of 10 6 to 10 7 revolutions; the spins must remain aligned over this time in order to avoid depolarization. Even extremely small spin deviations per revolution can add up and cause depolarization. The injection and the acceleration of polarized electrons in linacs is much easier. Although some improvements are still necessary, reliable polarized electron sources with sufficiently high intensity and polarization are available. With the linac-type machines SLC at Stanford and CEBAF in Virginia, experiments with polarized electrons will be possible

  3. Pressure drop in two-phase He I natural circulation loop at low vapour quality

    Energy Technology Data Exchange (ETDEWEB)

    Baudouy, B

    2003-01-01

    Steady state pressure drop in a two-phase He I natural circulation loop has been measured at atmospheric pressure. Results are obtained up to 0.2 exit vapor quality for a 14-mm diameter copper tube heated over a length of 1.2 m. Pressure drop assessment, done with the momentum balance equation including subcooling, reveals that the homogeneous model and Friedel's friction multiplier associated with Huq and Loth's void fraction correlations predict data within 15%. (author)

  4. High molecular weight non-polar hydrocarbons as pure model substances and in motor oil samples can be ionized without fragmentation by atmospheric pressure chemical ionization mass spectrometry.

    Science.gov (United States)

    Hourani, Nadim; Kuhnert, Nikolai

    2012-10-15

    High molecular weight non-polar hydrocarbons are still difficult to detect by mass spectrometry. Although several studies have targeted this problem, lack of good self-ionization has limited the ability of mass spectrometry to examine these hydrocarbons. Failure to control ion generation in the atmospheric pressure chemical ionization (APCI) source hampers the detection of intact stable gas-phase ions of non-polar hydrocarbon in mass spectrometry. Seventeen non-volatile non-polar hydrocarbons, reported to be difficult to ionize, were examined by an optimized APCI methodology using nitrogen as the reagent gas. All these analytes were successfully ionized as abundant and intact stable [M-H](+) ions without the use of any derivatization or adduct chemistry and without significant fragmentation. Application of the method to real-life hydrocarbon mixtures like light shredder waste and car motor oil was demonstrated. Despite numerous reports to the contrary, it is possible to ionize high molecular weight non-polar hydrocarbons by APCI, omitting the use of additives. This finding represents a significant step towards extending the applicability of mass spectrometry to non-polar hydrocarbon analyses in crude oil, petrochemical products, waste or food. Copyright © 2012 John Wiley & Sons, Ltd.

  5. Post-perovskite transitions in CaB4+O3 at high pressure

    International Nuclear Information System (INIS)

    Akaogi, M; Shirako, Y; Kojitani, H; Takamori, S; Yamaura, K; Takayama-Muromachi, E

    2010-01-01

    High-pressure phase transitions in CaRhO 3 were examined using a multianvil apparatus up to 27 GPa and 1930 o C. CaRhO 3 perovskite transforms to post-perovskite via a monoclinic intermediate phase with increasing pressure. Volume changes for the transitions of perovskite - intermediate phase and of intermediate phase - post-perovskite are -1.1 and -0.7 %, respectively. CaRhO 3 post-perovskite is the fourth quenchable post-perovskite oxide found so far. By high-temperature calorimetric experiments, enthalpy of the perovskite - post-perovskite transition in CaRuO 3 was measured as 15.2±3.3 kJ/mol. Combining the datum with those of CaIrO 3 , it is shown that CaIrO 3 perovskite is energetically less stable than CaRuO 3 perovskite. This is consistent with the fact that orthorhombic distortion of CaIrO 3 perovskite is larger than CaRuO 3 , as indicated with the tilt-angle of octahedral framework of perovskite structure. The transition pressure from perovskite to post-perovskite in CaBO 3 (B = Ru, Rh, Ir) increases almost linearly with decreasing the tilt-angle, suggesting that the perovskite - post-perovskite transition may result from instability of the perovskite structure with pressure.

  6. Highly-nonlinear polarization-maintaining As2Se3-based photonic quasi-crystal fiber for supercontinuum generation

    Science.gov (United States)

    Zhao, Tongtong; Lian, Zhenggang; Benson, Trevor; Wang, Xin; Zhang, Wan; Lou, Shuqin

    2017-11-01

    We propose an As2Se3-based photonic quasi-crystal fiber (PQF) with high nonlinearity and birefringence. By optimizing the structure parameters, a nonlinear coefficient up to 2079 W-1km-1 can be achieved at the wavelength of 2 μm; the birefringence reaches up to the order of 10-2 due to the introduction of large circular air holes in the cladding. Using an optical pulse with a peak power of 6 kW, a pulse width of 150 fs, and a central wavelength of 2.94 μm as the pump pulse, a mid-infrared polarized supercontinuum is obtained by using a 15 mm long PQF. The spectral width for x- and y-polarizations covers 1 μm-10.2 μm and 1 μm-12.5 μm, respectively. The polarization state can be well maintained when the incident angle of the input pulse changes within ±2°. The proposed PQF, with high nonlinear coefficient and birefringence, has potential applications in mid-infrared polarization-maintaining supercontinuum generation.

  7. High Blood Pressure (Hypertension)

    Science.gov (United States)

    ... Print Page Text Size: A A A Listen High Blood Pressure (Hypertension) Nearly 1 in 3 American adults has ... weight. How Will I Know if I Have High Blood Pressure? High blood pressure is a silent problem — you ...

  8. The effect of Demkov coupling in the rotational predissociation of 3He4He+, ch. 4

    International Nuclear Information System (INIS)

    Asselt, N.P.F.B. van; Maas, J.G.; Los, J.

    1976-01-01

    The momentum distribution of the 3 He + and the 4 He + fragments, both originating from rotational predissociation of 3 He 4 He + has been measured. There is a pronounced difference between the intensity distributions in both spectra. This difference is explained as the result of a Demkov coupling between the two lowest electronic states of the molecular ion. The rotational quantum numbers of the states involved are calculated from the spectra

  9. Long-Lifetime Low-Scatter Neutron Polarization Target

    International Nuclear Information System (INIS)

    Richardson, Jonathan M.

    2004-01-01

    Polarized neutrons scattering is an important technology for characterizing magnetic and other materials. Polarized helium three (P-3He) is a novel technology for creating polarized beams and, perhaps more importantly, for the analysis of polarization in highly divergent scattered beams. Analysis of scattered beams requires specialized targets with complex geometries to ensure accurate results. Special materials and handling procedures are required to give the targets a long useful lifetime. In most cases, the targets must be shielded from stray magnetic fields from nearby equipment. SRL has developed and demonstrated hybrid targets made from glass and aluminum. We have also developed and calibrated a low-field NMR system for measuring polarization lifetimes. We have demonstrated that our low-field system is able to measure NMR signals in the presence of conducting (metallic) cell elements. We have also demonstrated a non-magnetic valve that can be used to seal the cells. We feel that these accomplishments in Phase I are sufficient to ensure a successful Phase II program. The commercial market for this technology is solid. There are over nine neutron scattering centers in the US and Canada and over 22 abroad. Currently, the US plans to build a new $1.4B scattering facility called the Spallation Neutron Source (SNS). The technology developed in this project will allow SRL to supply targets to both existing and future facilities. SRL is also involved with the application of P-3He to medical imaging

  10. 3He release characteristics of metal tritides and scandium--tritium solid solutions

    International Nuclear Information System (INIS)

    Perkins, W.G.; Kass, W.J.; Beavis, L.C.

    1976-01-01

    Tritides of such metals as Sc, Ti, and Er are useful materials for determining the effects of He accumulation in metallic solids, for example, CTR first wall materials. Such effects include lattice strain and gross deformation which are related to 3 He retention and ultimate release. Long term gas release studies have indicated that, during the early life of a metal ditritide, a large fraction of the 3 He is retained in the solid. At more advanced ages, the 3 He release rate becomes comparable to the generation rate. Statistical analysis of the data indicates that the acceleration in 3 He release rate depends on accumulated 3 He concentration rather than strictly on age. 3 He outgassing results are presented for thin films of ScT 2 , TiT 2 , and ErT 2 , and the critical 3 He concentrations are discussed in terms of a percolation model. Phase transformations which occur on tritide formation cast some doubt on the validity of extrapolating results obtained for metal tritides to predictions regarding the accumulation of helium in metals. Sc is unique among the early transition and rare-earth metals in that the metal exhibits a very high room temperature T solubility (T/Sc = 0.4) with no phase transformation. Indeed, even the lattice parameters of the hcp Sc lattice are only minimally changed by T solution. Single crystal ScT/sub 0.3/ samples in two crystallographic orientations were obtained. Using a very sensitive technique, 3 He emission was measured from both these samples, as well as from fine-grained thin film Sc--T solid solution samples (ScT/sub 0.3-0.4/). The fine-grained film samples release 3 He at 2-3 percent of the generation rate, while the emission rate from the single-crystal samples is approximately 0.05 percent of the generation rate, indicating a strong grain size effect

  11. Diffusion of πsup(+-) mesons on D, 3He, 4He with a streamer self-shunted camera in a magnetic field

    International Nuclear Information System (INIS)

    Atanasov, A.; Angelescu, T.; Balea, O.; Balestra, F.; Busso, L.; Garfagnini, R.

    1975-01-01

    A streamer self-shunted camera has been developed with the study of interactions of πsup(+-) mesons on D, 3 He, 4 He. The camera can operate at high beam currents (10 sup(5)/10sup(6)ssup(-1)), so processes with small cross sections can be studied

  12. Development of Laser-Polarized Noble Gas Magnetic Resonance Imaging (MRI) Technology

    Science.gov (United States)

    Walsworth, Ronald L.

    2004-01-01

    We are developing technology for laser-polarized noble gas nuclear magnetic resonance (NMR), with the aim of enabling it as a novel biomedical imaging tool for ground-based and eventually space-based application. This emerging multidisciplinary technology enables high-resolution gas-space magnetic resonance imaging (MRI)-e.g., of lung ventilation, perfusion, and gas-exchange. In addition, laser-polarized noble gases (3He and 1BXe) do not require a large magnetic field for sensitive NMR detection, opening the door to practical MRI with novel, open-access magnet designs at very low magnetic fields (and hence in confined spaces). We are pursuing two specific aims in this technology development program. The first aim is to develop an open-access, low-field (less than 0.01 T) instrument for MRI studies of human gas inhalation as a function of subject orientation, and the second aim is to develop functional imaging of the lung using laser-polarized He-3 and Xe-129.

  13. Thermoelectric properties of high pressure synthesized lithium and calcium double-filled CoSb3

    Directory of Open Access Journals (Sweden)

    Xiaohui Li

    2017-01-01

    Full Text Available Lithium and calcium are inefficient filling elements of CoSb3 at ambient pressure, but show nice filling behavior under high pressure. In this work, we synthesized Li/Ca double-filled CoSb3 with high pressure synthesis method. The products show the skutterudite structure of Im3¯ symmetry. Thermoelectric properties were effectively enhanced through Li and Ca co-filling. For the optimal Li0.08Ca0.18Co4Sb12 sample, the power factor maintains a relatively high value over the whole measurement temperature range and peaks at 4700μWm−1K−2, meanwhile the lattice thermal conductivity is greatly suppressed, leading to a maximal ZT of 1.18 at 700 K. Current work demonstrates high pressure synthesis as an effective method to produce multiple elemental filled CoSb3 skutterudites.

  14. Recent progress in the development of a polarized proton target for reactions with radioactive ion beams

    International Nuclear Information System (INIS)

    Urrego-Blanco, J.P.; Bingham, C.R.; Brandt, B. van den; Galindo-Uribarri, A.; Gomez del Campo, J.; Hautle, P.; Konter, J.A.; Padilla-Rodal, E.; Schmelzbach, P.A.

    2007-01-01

    Polarization observables in nuclear reactions with stable beams have provided important information concerning structural properties of nuclei and reaction mechanisms and hold great promise in the context of exotic nuclei. We report on the development of a polarized target based on plastic foils of 20-200 μm thickness to be used with radioactive ion beams. The operation of such a target requires a moderately high magnetic field and very low temperatures. The plastic foil is placed inside a chamber attached to the mixing chamber of a 3 He- 4 He dilution refrigerator. Cooling of the foil is achieved via a superfluid film of 4 He that can be supplied through two capillaries. The chamber has two thin, highly uniform silicon nitride windows. An NMR coil is attached to the target to monitor the polarization. Results of a first test to characterize the target system, using the elastic scattering of 38 MeV 12 C by protons in inverse kinematics are presented

  15. Energy dependence and temporal evolution of the 3He/4He ratios in heavy-ion-rich energetic particle events

    International Nuclear Information System (INIS)

    Moebius, E.; Hovestadt, D.; Klecker, B.; Gloeckler, G.

    1980-01-01

    The energy dependence of the 3 He/ 4 He ratio between 0.44 and 4.1 MeV per nucleon has been studied for six heavy-ion--rich events observed in 1974 and 1976 using the low-energy dE/dx versus E Ultralow-Energy Particle telescope (ULET) on IMP 8. We find that all selected heavy-ion--rich events are also enriched in 3 He, that the 3 He/ 4 He He ratio decreases with decreasing energies, and that a rapid temporal evolution of the 3 He/ 4 He and the Fe/(H+He) ratios is strongly correlated during one event with the maximum value at the onset. These results are discussed in terms of a model which is based on preferential injection of 3 He and Fe resulting from turbulent ion heating and subsequent Fermi acceleration

  16. The production of He-3 and heavy ion enrichment in He-3-rich flares by electromagnetic hydrogen cyclotron waves

    Science.gov (United States)

    Temerin, M.; Roth, I.

    1992-01-01

    A new model is presented for the production of He-3 and heavy ion enrichments in He-3-rich flares using a direct single-stage mechanism. In analogy with the production of electromagnetic hydrogen cyclotron waves in earth's aurora by electron beams, it is suggested that such waves should exist in the electron acceleration region of impulsive solar flares. Both analytic and test-particle models of the effect of such waves in a nonuniform magnetic field show that these waves can selectively accelerate He-3 and heavy ions to MeV energies in a single-stage process, in contrast to other models which require a two-stage mechanism.

  17. NpX3 compounds under high pressure

    International Nuclear Information System (INIS)

    Zwirner, S.; Kalvius, G.M.

    1993-01-01

    The systematics of hyperfine interactions and the ordering temperature T ord in isostructural NpX 3 compounds (X=Al, Si, Ga, Ge, ln, Sn) are briefly reviewed. NpSn 3 has been viewed as a Kondo lattice system, similar to CeAl 2 , NpIn 3 shows a modulated magnetic structure including low moment and nonmagnetic contributions at ambient pressure and 4.2 K. Preliminary results of recent 237 Np Moessbauer studies on NpIn 3 at ambient pressure and various temperatures and at 4.0(8) GPa and 4.2 K are reported. At 4.0(8) GPa, T ord rises from 17 to 22 K, the low-moment contributions of the modulated structure are reduced and the non-magnetic site is lost below T ord . The variation of the hyperfine parameters and of T ord with pressure is similar to the behavior observed in NpSn 3 . (orig.)

  18. Bulk damping of sound in superfluid 3He--4He under stagnation of the normal component

    International Nuclear Information System (INIS)

    Karchava, T.A.; Sanikidze, D.G.; Chkhaidze, N.D.

    1983-01-01

    The propagation of waves in superfluid 3 He-- 4 He solutions is considered under partial stagnation of the normal component. The wave processes in capillaries are presented as a superposition of the first sound, second sound, and viscous and diffusion waves. The damping coefficients are calculated for the modified first sound and for the thermal wave in superfluid 3 He-- 4 He solutions and related to the viscosity, thermal conductivity, diffusion, barodiffusion, and thermodiffusion coefficients

  19. Excitation energy of a helium 3 quasiparticle in the bulk mixture at constant pressure

    International Nuclear Information System (INIS)

    Yim, M.B.

    1981-01-01

    A 3 He quasiparticle excitation energy in bulk mixture at zero pressure and 6% solution is calculated to O(x) using the bulk effective interaction of Yim and Massey. The present 3 He quasiparticle excitation energy is in agreement with the experimental result of Hilton, Scherm and Stirling. (author)

  20. X-ray diffraction study of WO{sub 3} at high pressure

    Energy Technology Data Exchange (ETDEWEB)

    Bouvier, P. [ESRF, Grenoble (France); Laboratoire d' Electrochimie et de Physico-Chimie des Materiaux et des Interfaces UMR 5631 CNRS-INPG, St. Martin d' Heres (France); Crichton, W.A. [ESRF, Grenoble (France); Boulova, M. [Laboratoire d' Electrochimie et de Physico-Chimie des Materiaux et des Interfaces UMR 5631 CNRS-INPG, St. Martin d' Heres (France); Chemistry Department, Moscow State University, Moscow (Russian Federation); Lucazeau, G. [Laboratoire d' Electrochimie et de Physico-Chimie des Materiaux et des Interfaces UMR 5631 CNRS-INPG, St. Martin d' Heres (France)

    2002-07-08

    The high-pressure behaviour of microcrystalline tungsten oxide (WO{sub 3}) has been investigated with angle-dispersive synchrotron x-ray powder diffraction in a diamond anvil cell up to 40 GPa at room temperature. Up to 21 GPa, the pressure dependence of the volume of the monoclinic high-pressure (P2{sub 1}/c) phase is described by a third-order Birch-Murnaghan equation of state with parameters V{sub 0}=210.9(7)A{sup 3}, K{sub T}=27(2)GP a and K'=9.4(5). At 24 GPa, a first-order phase transition occurs with an approximate {delta} V of 7.4% to a monoclinic P2{sub 1}/a unit cell with a=6.1669(8)A, b=4.5758(6)A, c=5.3159(6)A, {beta}=101.440(9) deg. A second transition is observed at pressures higher than 31 GPa with an approximate {delta} V of 12% to a phase described by a third monoclinic unit cell, with a=10.3633(22)A, b=3.9065(8)A, c=9.3459(18)A and {beta}=98.539(14) deg. (author)

  1. Lagrangian of superfluid 3He

    International Nuclear Information System (INIS)

    Theodorakis, S.

    1988-01-01

    This paper presents a phenomenological Lagrangian that fully describes the dynamics of any homogeneous phase of superfluid 3 He, unitary or not, omitting relaxation. This Lagrangian is built by using the concept of a local SO(3) x SO(3) x U(1) symmetry. The spin and angular momentum play the role of gauge fields. We derive the Leggett equations for spin and orbital dynamics from the equations of motion, for both the A and the B phase. This Lagrangian not only enables us to describe both the spin and orbital dynamics of superfluid 3 He in a unified fashion, but can also be used for finding the dynamics in any experimental situation. Furthermore, it can describe the dynamics of the magnitude, as well as of the orientation of the order parameter, and thus it can be used to describe the dynamics of the A-B phase transition

  2. The Cosmic Abundance of 3He: Green Bank Telescope Observations

    Science.gov (United States)

    Balser, Dana; Bania, Thomas

    2018-01-01

    The Big Bang theory for the origin of the Universe predicts that during the first ~1,000 seconds significant amounts of the light elements (2H, 3He, 4He, and 7Li) were produced. Many generations of stellar evolution in the Galaxy modifies these primordial abundances. Observations of the 3He+ hyperfine transition in Galactic HII regions reveals a 3He/H abundance ratio that is constant with Galactocentric radius to within the uncertainties, and is consistent with the primordial value as determined from cosmic microwave background experiments (e.g., WMAP). This "3He Plateau" indicates that the net production and destruction of 3He in stars is approximately zero. Recent stellar evolution models that include thermohaline mixing, however, predict that 3He/H abundance ratios should slightly decrease with Galactocentric radius, or in places in the Galaxy with lower star formation rates. Here we discuss sensitive Green Bank Telescope (GBT) observations of 3He+ at 3.46 cm in a subset of our HII region sample. We develop HII region models and derive accurate 3He/H abundance ratios to better constrain these new stellar evolution models.

  3. Analysis of the collagen birefringence and the relative attenuation coefficient of health and burned skin irradiated with linearly polarized He-Ne laser; Analise da birrefringencia do colageno e do coeficiente de atenuacao de amostras de pele sadia e queimada irradiadas pelo laser de He-Ne linearmente polarizado

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Daniela de Fatima Teixeira da

    2002-07-01

    Low-intensity laser therapy is characterized by its ability to induce athermic effects and nondestructive photobiological processes. Although it has been in use for more than 40 years, this phototherapy is still not an established therapeutic modality. The objectives of this study were: to quantify the collagen fibers organization by polarized light microscopy in normal and burned skin samples at day 17 post-injury considering preferential axis as the animal's spinal column and aligning the linear laser polarization in two directions of polarization, parallel or perpendicular to this axis; to determine the relative attenuation coefficient for the intensity light by the technique of imaging the light distribution in normal and burned skin during wound healing process taking only parallel direction of polarization. To reach the objectives, burns about 6 mm in diameter were created with liquid N{sub 2} on the back of the rats and the lesions were irradiated on days 3, 7, 10 and 14 post-wounding, D= 1 J/cm{sup 2}, to investigate the effects of low-intensity linearly polarized He-Ne laser beam on skin wounds healing. Control lesions were not irradiated. The results have demonstrated that: the skin samples irradiated with linearly parallel polarized He-Ne laser beam showed collagen fibers more organized; burned skin samples presents a higher attenuation coefficient than normal skin samples. These results are important to optimize low intensity laser therapy dosimetry on acceleration wound healing. (author)

  4. High-efficiency resonant rf spin rotator with broad phase space acceptance for pulsed polarized cold neutron beams

    Directory of Open Access Journals (Sweden)

    P.-N. Seo

    2008-08-01

    Full Text Available High precision fundamental neutron physics experiments have been proposed for the intense pulsed spallation neutron beams at JSNS, LANSCE, and SNS to test the standard model and search for new physics. Certain systematic effects in some of these experiments have to be controlled at the few ppb level. The NPDGamma experiment, a search for the small parity-violating γ-ray asymmetry A_{γ} in polarized cold neutron capture on parahydrogen, is one example. For the NPDGamma experiment we developed a radio-frequency resonant spin rotator to reverse the neutron polarization in a 9.5  cm×9.5  cm pulsed cold neutron beam with high efficiency over a broad cold neutron energy range. The effect of the spin reversal by the rotator on the neutron beam phase space is compared qualitatively to rf neutron spin flippers based on adiabatic fast passage. We discuss the design of the spin rotator and describe two types of transmission-based neutron spin-flip efficiency measurements where the neutron beam was both polarized and analyzed by optically polarized ^{3}He neutron spin filters. The efficiency of the spin rotator was measured at LANSCE to be 98.8±0.5% for neutron energies from 3 to 20 meV over the full phase space of the beam. Systematic effects that the rf spin rotator introduces to the NPDGamma experiment are considered.

  5. Eilenberger equation for rotating superfluid 3He and calculation of the upper critical angular velocity Ω/sub c/2

    International Nuclear Information System (INIS)

    Schopohl, N.

    1980-01-01

    On the basis of Gorkov's formulation of superconductivity theory, generalized Eilenberger equations are derived which apply to rotating superfluid 3 He in the presence of a magnetic field h and finite superflow v. In analyogy to conventional type II superconductors, the possibility of vortex solutions in discussed. An implicit equation determining the upper critical angular velocity Ω/sub c/2 as a function of temperature T, magnetic field h, and superflow v parallel to the rotation axis is-inferred from the linearized Eilenberger equations. In contrast to the case of slowly rotating 3 He-A, the solution of the eigenvalue problem determining the order parameter Δ near the the upper critical angular velocity admits no coreless vortex no coreless solutions. The space-dependent amplitude of the order parameter is analogous to Abrikosov's vortex array solution, while the spin-orbit part is given either by a polar-state type or an Anderson-Brinkman-Morel (ABM)-state-type eigensolution. Among the possible eigensolutions the polar-state type yields for vanishing superflow v the highest critical rotation frequency. For finite superflow v parallel to the rotation axis, however, the ABM-state-type solution is stabilized in comparison to the polar state for Vertical BarvVertical Bar> or approx. =0.2π(Tc/sub c/0/T/sub F/)v/sub f/ at zero temperature

  6. High oxygen partial pressure increases photodynamic effect on HeLa cell lines in the presence of chloraluminium phthalocyanine.

    Science.gov (United States)

    Bajgar, Robert; Kolarova, Hana; Bolek, Lukas; Binder, Svatopluk; Pizova, Klara; Hanakova, Adela

    2014-08-01

    Photodynamic therapy (PDT) is linked with oxidative damage of biomolecules causing significant impairment of essential cellular functions that lead to cell death. It is the reason why photodynamic therapy has found application in treatment of different oncological, cardiovascular, skin and eye diseases. Efficacy of PDT depends on combined action of three components; sensitizer, light and oxygen. In the present study, we examined whether higher partial pressure of oxygen increases lethality in HeLa cell lines exposed to light in the presence of chloraluminium phthalocyanine disulfonate (ClAlPcS2). ClAlPcS2- sensitized HeLa cells incubated under different oxygen conditions were exposed to PDT. Production of singlet oxygen ((1)O2) and other forms of reactive oxygen species (ROS) as well as changes in mitochondrial membrane potential were determined by appropriately sensitive fluorescence probes. The effect of PDT on HeLa cell viability under different oxygen conditions was quantified using the standard methylthiazol tetrazolium (MTT) test. At the highest oxygen concentration of 28 ± 2 mg/l HeLa cells were significantly more sensitive to light-activated ClAlPcS2 (EC50=0.29 ± 0.05 μM) in comparison to cells incubated at lower oxygen concentrations of 8 ± 0.5 and 0.5 ± 0.1 mg/l, where the half maximal effective concentration was 0.42 ± 0.06 μM and 0.94 ± 0.14 μM, respectively. Moreover, we found that the higher presence of oxygen is accompanied with higher production of singlet oxygen, a higher rate of type II photodynamic reactions, and a significant drop in the mitochondrial membrane potential. These results demonstrate that the photodynamic effect in cervical cancer cells utilizing ClAlPcS2 significantly depends on oxygen level. Copyright© 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  7. Foam glass obtained through high-pressure sintering

    DEFF Research Database (Denmark)

    Østergaard, Martin Bonderup; Petersen, Rasmus Rosenlund; König, Jakob

    2018-01-01

    Foam glasses are usually prepared through a chemical approach, that is, by mixing glass powder with foaming agents, and heating the mixture to a temperature above the softening point (106.6 Pa s) of the glass. The foaming agents release gas, enabling expansion of the sintered glass. Here, we use...... a physical foaming approach to prepare foam glass. First, closed pores filled with inert gases (He, Ar, or N2) are physically introduced into a glass body by sintering cathode ray tube (CRT) panel glass powder at high gas pressure (5‐25 MPa) at 640°C and, then cooled to room temperature. The sintered bodies...... are subjected to a second heat treatment above the glass transition temperature at atmospheric pressure. This heat treatment causes expansion of the pores due to high internal gas pressure. We found that the foaming ability strongly depends on the gas pressure applied during sintering, and on the kinetic...

  8. PuBr3-type as high pressure modification of rare earth trihalides LnX3 (X = Cl, Br, I)

    International Nuclear Information System (INIS)

    Beck, H.P.; Gladrow, E.

    1983-01-01

    High pressure experiments in a belt-type apparatus were performed on rare earth trichlorides, -bromides and -iodides. The results underline the importance of the PuBr 3 -type arrangement. The range of existence of this structure type is considerably increased under pressure. X-ray high temperature investigations at ambient pressure on the quenched high pressure phases show a marked correlation between the transformation pressures, which rise with smaller cations, and the temperatures at which the high pressure phases are reconverted to the thermodynamically stable ones. (author)

  9. A Precision Measurement of the Transverse Asymmetry AT from Quasi-elastic 3He(e,e') process, and the Neutron Magnetic Form Factor GNM at low Q2

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Wang [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2002-06-01

    Electromagnetic form factors are fundamental quantities in describing the underlying electromagnetic structure of nucleons. While proton electromagnetic form factors have been determined with good precision, neutron form factors are known poorly, largely due to the lack of free neutron targets. Jefferson Lab Hall A experiment E95-001, a ''precise measurement of the transverse asymmetry AT' from the quasielastic 3He(e, e') process,'' was therefore designed to determine precisely the neutron magnetic form factor, G$n\\atop{M}$ at low momentum transfer values and was successfully completed in Spring 1999. High precision AT'data in the quasi-elastic region at Q2 values of 0.1 to 0.6 (GeV/c)2 were obtained using a high-pressure spin-exchange optically-pumped polarized 3He gas target with an average polarization of 30%, a longitudinally polarized e- beam, and two High Resolution Spectrometers: HRSe and HRSh. HRSe was employed to detect scattered electrons from the quasi-elastic kinematic region, and HRSh was employed as a elastic polarimetry to monitor the product of the beam and target polarizations. The extraction of form factors is usually model-dependent. Significant constraints on theoretical calculations are provided bu additional high precision quasi-elastic asymmetry data at Q2 values of 0.1 and 0.2 (GeV/c)2 in 3He breakup region, where effects of final state interactions (FSI) and meson exchange currents (MEC) are expected to be large [71]. G$n\\atop{M}$ is extracted from a non-relativistic Faddeev calculation which includes both FSI and MEC at Q2 values of 0.1 and 0.2 (GeV/c)2. The uncertainties of G$n\\atop{M}$ at these Q2 values are comparable to those of recent experiments with deuterium targets [58]. At the higher Q2 values from this experiment, G$n\\atop{M}$ is extracted

  10. Irradiated NH3 and ND3 - two new target materials for polarized targets

    International Nuclear Information System (INIS)

    Meyer, W.

    1982-11-01

    A study of dynamic nuclear polarization (DNP) in NH 3 and ND 3 was made at the Bonn 2.5 GeV electron synchrotron. The paramagnetic radicals in the polycristalline ammonia beads were created by irradiation in the high intensity 20 MeV electron beam (> 10 14 electrons/sec) of the injection linac. During irradiation the ammonia beads, produced by dropping into liquid nitrogen, were cooled in liquid argon at approx.= 90 K. DNP measurements were performed at 1 K, 0.5 K and 0.2 K in a 2.5 T magnetic field. Samples of NH 3 , prepared in this way, yielded a maximum proton polarization of 66% at a temperature of 0.5 K with a short polarization build-up time of 9 minutes. ND 3 could be polarized at a temperature of 0.2 K up to 31%. The radiation resistance of the polarization of NH 3 is better than that of butanol. (orig.)

  11. PENGUKURAN SIFAT POLARISASI BERBAGAI MINYAK NABATI MENGGUNAKAN LAMPU IR DAN LASER HE-NE

    Directory of Open Access Journals (Sweden)

    U Kaltsum

    2017-03-01

    Full Text Available Penelitian ini bertujuan untuk menguji sifat polarisasi berbagai minyak nabati (minyak sawit, minyak kedelai, minyak zaitun, VCO, minyak curah, dan jelantah dengan variasi keadaan baru dan kadaluwarsa, menggunakan lampu IR dan laser He-Ne. Pengujian dilakukan dengan menempatkan minyak nabati diantara polarisator dan analisator. Hasil penelitian pada kedua sumber cahaya menunjukkan pola yang hampir sama. Minyak zaitun dan VCO memiliki perubahan sudut polarisasi alami kecil, sedangkan minyak sawit, kedelai, jelantah, dan curah memiliki perubahan sudut polarisasi alami besar. Besarnya perubahan sudut polarisasi minyak kadaluwarsa lebih besar dibanding minyak baru. Perubahan sudut polarisasi sebanding dengan jumlah radikal bebas (ALB, peroksida dan molekul asimetri (asam lemak jenuh, molekul rantai panjang. Meskipun pola yang dihasilkan oleh kedua sumber cahaya sama, namun lampu IR memberikan nilai perubahan sudut polarisasi yang lebih tinggi dari laser He-Ne. Hal ini dimungkinkan karena daya lampu IR lebih besar dari He-Ne, sehingga energi yang dihasilkan lampu IR lebih tinggi dan perubahan sudut polarisasinya lebih besar. This research based on previous research that using IR lamp (250 watt and He-Ne laser (1 mW on a mixture of palm oil and animal oil. Both of light source were used again to measure polarization properties of various vegetable oils (palm oil, soybean oil, olive oil, VCO, rainfall oil and used cooking oil with a variety of new and expired. The tools used were a set polarization, IR lamp, He-Ne laser, and power supply. The experiment was done by placing vegetable oil between the polarizer and analyzers. The result showed both of light sources had similar pattern; polarization changes of olive oil and the VCO were small, while polarization changes of palm oil, soybean oil, used cooking oil, and rainfall were high. Polarization change of expired oil was higher than new oil. The value of polarization change was proportional to free

  12. 3He release characteristics of metal tritides and scandium--tritium solid solutions

    International Nuclear Information System (INIS)

    Perkins, W.G.; Kass, W.J.; Beavis, L.C.

    1975-01-01

    Tritides of such metals as scandium, titanium, and erbium are useful materials for determining the effects of helium accumulation in metallic solids, for example, CTR first wall materials. Such effects include lattice strain and gross deformation, as reported elsewhere, which are related to 3 He retention and ultimate release. Long term gas release studies have indicated that, during the early life of a metal ditritide, a large fraction of the 3 He is retained in the solid. At more advanced ages (2 to 4 years, depending on the parent metal), the 3 He release rate becomes comparable to the generation rate. Statistical analysis of the data indicates that the acceleration in 3 He release rate depends on accumulated 3 He concentration rather than strictly on age. 3 He outgassing results are presented for thin films of ScT 2 , TiT 2 , and ErT 2 , and the critical 3 He concentrations are discussed in terms of a percolation model. Phase transformations which occur on tritide formation cast some doubt on the validity of extrapolating results obtained for metal tritides to predictions regarding the accumulation of helium in metals. Scandium is unique among the early transition and rare-earth metals in that the metal exhibits a very high room temperature tritium solubility (T/Sc = 0.4) with no phase transformation. Indeed, even the lattice parameters of the hcp scandium lattice are only minimally changed by tritium solution, and we have succeeded in obtaining single crystal ScT 0 . 3 samples in two crystallographic orientations. Using a very sensitive technique, we have measured 3 He emission from both these samples, as well as from fine-grained thin film scandium-tritium solid solution samples (ScT 0 . 3 - 0 . 4 ). The fine-grained film samples release 3 He at 2 to 3 percent of the generation rate, while the emission rate from the single-crystal samples is approximately 0.05 percent of the generation rate, indicating a strong grain size effect

  13. Measurement of the Target-Normal Single-Spin Asymmetry in Deep-Inelastic Scattering from the Reaction 3He{uparrow}(e,e')X

    Energy Technology Data Exchange (ETDEWEB)

    Katich, Joseph; Qian, Xin; Zhao, Yuxiang; Allada, Kalyan; Aniol, Konrad; Annand, John; Averett, Todd; Benmokhtar, Fatiha; Bertozzi, William; Bradshaw, Elliott; Bosted, Peter; Camsonne, Alexandre; Canan, Mustafa; Cates, Gordon; Chen, Chunhua; Chen, Jian-Ping; Chen, Wei; Chirapatpimol, Khem; Chudakov, Eugene; Cisbani, Evaristo; Cornejo, Juan; Cusanno, Francesco; Dalton, Mark; Deconinck, Wouter; De Jager, Cornelis; De Leo, Raffaele; Deng, Xiaoyan; Deur, Alexandre; Ding, Huaibo; Dolph, Peter; Dutta, Chiranjib; Dutta, Dipangkar; El Fassi, Lamiaa; Frullani, Salvatore; Gao, Haiyan; Garibaldi, Franco; Gaskell, David; Gilad, Gilad; Gilman, Ronald; Glamazdin, Oleksandr; Golge, Serkan; Guo, Lei; Hamilton, David; Hansen, Jens-Ole; Higinbotham, Douglas; Holmstrom, Timothy; Huang, Jijun; Huang, Min; Ibrahim Abdalla, Hassan; Iodice, Mauro; Jin, Ge; Jones, Mark; Kelleher, Aidan; Kim, Wooyoung; Kolarkar, Ameya; Korsch, Wolfgang; LeRose, John; Li, Xiaomei; Li, Y; Lindgren, Richard; Liyanage, Nilanga; Long, Elena; Lu, Hai-jiang; Margaziotis, Demetrius; Markowitz, Pete; Marrone, Stefano; McNulty, Dustin; Meziani, Zein-Eddine; Michaels, Robert; Moffit, Bryan; Munoz Camacho, Carlos; Nanda, Sirish; Narayan, Amrendra; Nelyubin, Vladimir; Norum, Blaine; Oh, Yoomin; Osipenko, Mikhail; Parno, Diana; Peng, Jen-chieh; Phillips, Sarah; Posik, Matthew; Puckett, Andrew; Qiang, Yi; Rakhman, Abdurahim; Ransome, Ronald; Riordan, Seamus; Saha, Arunava; Sawatzky, Bradley; Schulte, Elaine; Shahinyan, Albert; Hashemi Shabestari, Mitra; Sirca, Simon; Stepanyan, Stepan; Subedi, Ramesh; Sulkosky, Vincent; Tang, Liguang; Tobias, William; Urciuoli, Guido; Vilardi, Ignazio; Wang, Kebin; Wang, Y; Wojtsekhowski, Bogdan; Yan, X; Yao, Huan; Ye, Yunxiu; Ye, Z; Yuan, Lulin; Zhan, Xiaohui; Zhang, Yi; Zhang, Y -W; Zhao, Bo; Zheng, Xiaochao; Zhu, Lingyan; Zhu, Xiaofeng; Zong, Xing

    2014-07-01

    We report the first measurement of the target single-spin asymmetry in deep-inelastic scattering from the inclusive reaction 3He{uparrow}(e,e')X on a 3He gas target polarized normal to the lepton plane. Assuming time-reversal invariance, this asymmetry is strictly zero in the Born approximation. The experiment, conducted at Jefferson Lab using a 5.89 GeV electron beam, covers a range of 1.7polarization and measured proton-to-3He cross section ratios. The measured neutron asymmetries are negative with an average value of (−1.04+/-0.38)×10−2 for invariant mass W>2 GeV, which is non-zero at the 2.75sigma level. Theoretical calculations, which assume two-photon exchange with quasi-free quarks, predict a neutron asymmetry of O(10−4) when both photons couple to one quark, and O(10−2) for the photons coupling to different quarks. Our measured asymmetry agrees both in sign and magnitude with the prediction that uses input based on the Sivers transverse momentum distribution obtained from semi-inclusive deep-inelastic scattering.

  14. Polarized proton beams since the ZGS

    International Nuclear Information System (INIS)

    Krisch, A.D.

    1994-01-01

    The author discusses research involving polarized proton beams since the ZGS's demise. He begins by reminding the attendee that in 1973 the ZGS accelerated the world's first high energy polarized proton beam; all in attendance at this meeting can be proud of this accomplishment. A few ZGS polarized proton beam experiments were done in the early 1970's; then from about 1976 until 1 October 1979, the majority of the ZGS running time was polarized running. A great deal of fundamental physics was done with the polarized beam when the ZGS ran as a dedicated polarized proton beam from about Fall 1977 until it shut down on 1 October 1979. The newly created polarization enthusiats then dispersed; some spread polarized seeds al over the world by polarizing beams elsewhere; some wound up running the High Energy and SSC programs at DOE

  15. 3He-MRI in follow-up of lung transplant recipients

    International Nuclear Information System (INIS)

    Gast, Klaus Kurt; Zaporozhan, Julia; Ley, Sebastian; Biedermann, Alexander; Knitz, Frank; Eberle, Balthasar; Schmiedeskamp, Joerg; Heussel, Claus-Peter; Mayer, Eckhard; Schreiber, Wolfgang Guenter; Thelen, Manfred; Kauczor, Hans-Ulrich

    2004-01-01

    The aim of this study was to evaluate the possible contribution of 3 He-MRI to detect obliterative bronchiolitis (OB) in the follow-up of lung transplant recipients. Nine single- and double-lung transplanted patients were studied by an initial and a follow-up 3 He-MRI study. Images were evaluated subjectively by estimation of ventilation defect area and quantitatively by individually adapted threshold segmentation and subsequent calculation of ventilated lung volume. Bronchiolitis obliterans syndrome (BOS) was diagnosed using pulmonary function tests. At 3 He-MRI, OB was suspected if ventilated lung volume had decreased by 10% or more at the follow-up MRI study compared with the initial study. General accordance between pulmonary function testing and 3 He-MRI was good, although subjective evaluation of 3 He-MRI underestimated improvement in ventilation as obtained by pulmonary function tests. The 3 He-MRI indicated OB in 6 cases. According to pulmonary function tests, BOS was diagnosed in 5 cases. All diagnoses of BOS were also detected by 3 He-MRI. In 2 of these 5 cases, 3 He-MRI indicated OB earlier than pulmonary function tests. The results support the hypothesis that 3 He-MRI may be sensitive for early detection of OB and emphasize the need for larger prospective follow-up studies. (orig.)

  16. Measurement of the 3He Spin Structure Functions in the Resonance Region: A Test of Quark-Hadron Duality on the Neutron

    Energy Technology Data Exchange (ETDEWEB)

    Solvignon, Patricia [Temple Univ., Philadelphia, PA (United States)

    2006-08-01

    One of the biggest challenges in the study of the nucleon structure is the understanding of the transition from partonic degrees of freedom to hadronic degrees of freedom. In 1970, Bloom and Gilman noticed that structure function data taken at SLAC in the resonance region average to the scaling curve of deep inelastic scattering (DIS). Early theoretical interpretations suggested that these two very different regimes can be linked under the condition that the quark-gluon and quark-quark interactions are suppressed. Substantial efforts are ongoing to investigate this phenomenon both experimentally and theoretically. Quark-hadron duality has been confirmed for the unpolarized structure function F2 of the proton and the deuteron using data from the experimental Hall C at Jefferson Lab (JLab). Indications of duality have been seen for the proton polarized structure function g1 and the virtual photon asymmetry A1 at JLab Hall B and HERMES. Because of the different resonance behavior, it is expected that the onset of duality for the neutron will happen at lower momentum transfer than for the proton. Now that precise spin structure data in the DIS region are available at large x, data in the resonance region are greatly needed in order to test duality in spin-dependent structure functions. The goal of experiment E01-012 was to provide such data on the neutron (3He) in the moderate momentum transfer (Q2) region, 1.0 < Q2 < 4.0 (GeV/c2), where duality is expected to hold. The experiment ran successfully in early 2003 at Jefferson Lab in Hall B. It was an inclusive measurement of longitudinally polarized electrons scattering from a longitudinally or transversely polarized 3He target. Asymmetries and cross section differences were measured in order to extract the 3He spin structure function g1 and virtual photon asymmetry A1 in the resonance region. A test

  17. Contribution to the experimental study of the polarized liquid helium-3; Contributions a l'etude experimentale de l'helium-3 liquide polarise

    Energy Technology Data Exchange (ETDEWEB)

    Villard, B

    1999-07-15

    Spin-polarized liquid helium-3 is prepared by laser optical pumping in low magnetic field and at room temperature, prior to fast liquefaction of the polarized sample. The use of a new helium-3 cryostat enabled us to obtain liquid helium-3 with polarization rates up to 25 % at well-stabilized temperatures (around 0.5 K). We could thereby study the effect of nuclear polarization on liquid-vapour equilibrium, and particularly on the saturated vapour pressure. Very sensitive capacitive gauges were developed. We estimated (to first order in M{sup 2}) the expected effects when the polarization M is suddenly destroyed. These effects were experimentally observed in helium-3/helium-4 mixtures, in pure helium-3, only a transient increase in pressure has been recorded. We then describe in a third part a preliminary experiment which aimed at determining the longitudinal relaxation time T1 in mixtures. Relaxation on the walls is efficiently reduced by a cesium coating and T1s of order 20 minutes were observed. A careful determination of the helium-3 concentration in the liquid phase was made. Finally we studied the effects of dipolar field on transverse polarisation decay in our strongly polarized samples. We observed the free precession of polarization after a NMR pulse, and analysed in detail its decay time constant as a function of different parameters. This time constant drastically varied with the tipping angle, an effect which could be linked to NMR dynamical instabilities. (author)

  18. Field-induced spin splitting and anomalous photoluminescence circular polarization in C H3N H3Pb I3 films at high magnetic field

    Science.gov (United States)

    Zhang, Chuang; Sun, Dali; Yu, Zhi-Gang; Sheng, Chuan-Xiang; McGill, Stephen; Semenov, Dmitry; Vardeny, Zeev Valy

    2018-04-01

    The organic-inorganic hybrid perovskites show excellent optical and electrical properties for photovoltaic and a myriad of other optoelectronics applications. Using high-field magneto-optical measurements up to 17.5 T at cryogenic temperatures, we have studied the spin-dependent optical transitions in the prototype C H3N H3Pb I3 , which are manifested in the field-induced circularly polarized photoluminescence emission. The energy splitting between left and right circularly polarized emission bands is measured to be ˜1.5 meV at 17.5 T, from which we obtained an exciton effective g factor of ˜1.32. Also from the photoluminescence diamagnetic shift we estimate the exciton binding energy to be ˜17 meV at low temperature. Surprisingly, the corresponding field-induced circular polarization is "anomalous" in that the photoluminescence emission of the higher split energy band is stronger than that of the lower split band. This "reversed" intensity ratio originates from the combination of long electron spin relaxation time and hole negative g factor in C H3N H3Pb I3 , which are in agreement with a model based on the k.p effective-mass approximation.

  19. Polarization holographic optical recording of a new photochromic diarylethene

    Science.gov (United States)

    Pu, Shouzhi; Miao, Wenjuan; Chen, Anyin; Cui, Shiqiang

    2008-12-01

    A new symmetrical photochromic diarylethene, 1,2-bis[2-methyl-5-(3-methoxylphenyl)-3-thienyl]perfluorocyclopentene (1a), was synthesized, and its photochromic properties were investigated. The compound exhibited good photochromism both in solution and in PMMA film with alternating irradiation by UV/VIS light, and the maxima absorption of its closed-ring isomer 1b are 582 and 599 nm, respectively. Using diarylethene 1b/PMMA film as recording medium and a He-Ne laser (633 nm) for recording and readout, four types of polarization and angular multiplexing holographic optical recording were performed perfectly. For different types of polarization recording including parallel linear polarization recording, parallel circular polarization recording, orthogonal linear polarization recording and orthogonal circular polarization recording,have been accomplished successfully. The results demonstrated that the orthogonal circular polarization recording is the best method for polarization holographic optical recording when this compound was used as recording material. With angular multiplexing recording technology, two high contrast holograms were recorded in the same place on the film with the dimension of 0.78 μm2.

  20. Note: Coincidence measurements of 3He and neutrons from a compact D-D neutron generator

    Science.gov (United States)

    Ji, Q.; Lin, C.-J.; Tindall, C.; Garcia-Sciveres, M.; Schenkel, T.; Ludewigt, B. A.

    2017-05-01

    Tagging of neutrons (2.45 MeV) with their associated 3He particles from deuterium-deuterium (D-D) fusion reactions has been demonstrated in a compact neutron generator setup enabled by a high brightness, microwave-driven ion source with a high fraction of deuterons. Energy spectra with well separated peaks of the D-D fusion reaction products, 3He, tritons, and protons, were measured with a silicon PIN diode. The neutrons were detected using a liquid scintillator detector with pulse shape discrimination. By correlating the 3He detection events with the neutron detection in time, we demonstrated the tagging of emitted neutrons with 3He particles detected with a Si PIN diode detector mounted inside the neutron generator vacuum vessel.

  1. Measurement of the Electrical Conductivity of He{sup 3} Plasma Induced by Neutron Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Braun, J; Nygaard, K

    1966-03-15

    The conductivity of a He plasma created by the inelastic reaction with thermal neutrons: {sup 3}He + n{sub th} -> {sup 3}H + p + 0.76 MeV is studied as a function of neutron flux, gas temperature and gas density. Using reported values of the electron mobility the electron density is calculated from experimental conductivity values. Further, by accepting a reasonable value for the mean energy lost in creating one ion-pair, the recombination coefficient is estimated. The measurements performed so far cover temperatures between 300 - 1600 K and densities between 0.25 - 1 times the density at atmospheric pressure and 300 K. The neutron flux is varied between 10{sup 10} - 10{sup 11} n/cm{sup 2}/s. As a sample of results achieved at 1600 K and the lowest density (corresponding to about atmospheric pressure) and the highest neutron flux the following values are obtained for the conductivity, the electron density and the recombination coefficient respectively: {sigma} 0.2 S/m, n{sub e} 6x10{sup 11}/cm{sup 3}, {alpha} = 2xl0{sup -10} cm{sup 3}/s. An extrapolation of data obtained shows that the concept of neutron induced conductivity should be attractive for MHD power generation.

  2. InN{0001} polarity by ion scattering spectroscopy

    International Nuclear Information System (INIS)

    Walker, M.; Veal, T.D.; McConville, C.F.; Lu, Hai; Schaff, W.J.

    2005-01-01

    The polarity of a wurtzite InN thin film grown on a c-plane sapphire substrate with GaN and AlN buffer layers has been investigated by co-axial impact collision ion scattering spectroscopy (CAICISS). Time of flight (TOF) spectra of He + ions scattered from the surface of the InN film were taken as a function of the incident angles of the primary 3 keV He + ions. From the TOF spectra, the polar angle-dependence of the In scattered intensity was obtained. Comparison of the experimental polar-angle dependence of the In CAICISS signal intensity with simulated results for the various volume ratios of (0001)- and (000 anti 1)-polarity domains indicated that the InN film is approximately 75% In-polarity and 25% N-polarity. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  3. Transport properties of Heusler Compound Mn3Si under high pressure

    International Nuclear Information System (INIS)

    Takaesu, Y; Uchima, K; Nakamura, S; Yogi, M; Niki, H; Hedo, M; Nakama, T; Tomiyoshi, S

    2014-01-01

    The electrical resistivity ρ and the thermopower S of the single crystalline sample of the Heusler compound Mn 3 Si have been measured in the temperature range between 2 and 300 K under high pressures up to 2.2 GPa. The temperature variations of ρ and S indicate the characteristic features at the Néel temperature T N . An additional anomaly in S(T), related to the 3Q satellites in SDW, is observed at P > 1 GPa, and it disappears at P > 1 GPa. The Néel temperature, obtained from ρ(T) and S(T) curves, increases with increasing pressure. The pressure dependences of the residual resistivity and the thermopower at T = 2 K show the discontinuous changes at P ≈ 1 GPa, indicating a pressure induced phase transition

  4. A high field optical-pumping spin-exchange polarized deuterium source

    International Nuclear Information System (INIS)

    Coulter, K.P.; Holt, R.J.; Kinney, E.R.; Kowalczyk, R.S.; Poelker, M.; Potterveld, D.H.; Young, L.; Zeidman, B.; Toporkov, D.

    1992-01-01

    Recent results from a prototype high field optical-pumping spin-exchange polarized deuterium source are presented. Atomic polarization as high as 62% have been observed with an intensity of 6.3 x 10 17 atoms-sec -1 and 65% dissociation fraction

  5. /sup 3/He functions in tokamak-pumped laser systems

    Energy Technology Data Exchange (ETDEWEB)

    Jassby, D.L.

    1986-10-01

    /sup 3/He placed in an annular cell around a tokamak fusion generator can convert moderated fusion neutrons to energetic ions by the /sup 3/He(n,p)T reaction, and thereby excite gaseous lasants mixed with the /sup 3/He while simultaneously breeding tritium. The total /sup 3/He inventory is about 4 kg for large tokamak devices. Special configurations of toroidal-field magnets, neutron moderators and beryllium reflectors are required to permit nearly uniform neutron current into the laser cell with minimal attenuation. The annular laser radiation can be combined into a single output beam at the top of the tokamak.

  6. The new phases of liquid 3He

    International Nuclear Information System (INIS)

    Leggett, A.J.

    1976-01-01

    Comments are made on two new phases of liquid 3 He, referred to as 3 He-A and 3 He-B, discovered in the temperature region below 3 mk. It has been assumed that these new phases are anisotropic superfluids, and a general picture of them is presented, which has been successful in explaining at least qualitatively, many of the static, dynamic and transport properties of the new phases. Whilst the qualitative behaviour is in good agreement with theory there are, however, some quantitative discrepancies. In many cases these may be due to orientational and geometric effects not yet understood. One of the most fruitful areas for comparison of theory and experiment is the NMR behaviour and the dynamic nuclear magnetism. The anomalous behaviour observed arises because the nuclear dipole energy, although very small, can act coherently in the superfluid state. (U.K.)

  7. Pressure effects on the 2D electron system in LaAlO{sub 3}/SrTiO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Borisov, Vladislav; Jeschke, Harald O.; Valenti, Roser [Institute of Theoretical Physics, Goethe University, D-60438 Frankfurt am Main (Germany); Zabaleta, Jone [Max Planck Institute for Solid State Research, D-70569 Stuttgart (Germany); Kopp, Thilo [Center for Electronic Correlations and Magnetism, Experimental Physics VI, Institute of Physics, University of Augsburg, D-86135 Augsburg (Germany)

    2016-07-01

    We present a theoretical study of pressure effects on the electronic properties of the LaAlO{sub 3}/SrTiO{sub 3} (001) interface. Lattice relaxation plays a crucial role for the formation of the 2D electron system (2DES), in agreement with previous reports. We observe that the carrier density of the 2DES at zero pressure is much lower than the ''polar catastrophe'' estimate of 0.5 e{sup -} per two-dimensional unit cell, which agrees with most experimental works. Under hydrostatic pressure, structural distortions in LaAlO{sub 3} (LAO) are largely suppressed, whereas they increase in SrTiO{sub 3} (STO), and the carrier density of the 2DES is enhanced by almost 45% using a moderate pressure of 4.1 GPa. The origin of this behavior as well as the explanation for the low carrier density at the interface at ambient pressure are discussed in terms of the lattice polarization and electronic Berry phase in the LAO oxide. Reduction of the calculated static dielectric constants of LAO and STO under pressure might account for the recent experimental findings regarding the carrier mobility.

  8. Towards accurate T-3He Q-value

    Energy Technology Data Exchange (ETDEWEB)

    Eronen, Tommi; Hoecker, Martin; Ketter, Jochen; Streubel, Sebastian; Blaum, Klaus [Max-Planck Institut fuer Kernphysik, Heidelberg (Germany); Van Dyck, Robert S. Jr. [Department of Physics, University of Washington, Seattle, WA (United States)

    2013-07-01

    Great efforts have been put forward to determine the neutrino mass from tritium β decay. The most prominent experimental setup, KATRIN, is expected to deliver an upper limit to the neutrino mass that is one order of magnitude more stringent than the current value by measuring the endpoint and the shape of the β spectrum of the tritium decay. The endpoint energy (assuming zero neutrino mass) can also be deduced from the Q-value of the decay by measuring the mass difference of tritium and the daughter {sup 3}He using high-resolution mass spectrometry. Such a measurement would give an excellent, independent calibration point for the KATRIN experiment to deduce its systematics. Our mass-difference measurement utilizes the Tritium- Helium double Penning trap (THe-Trap) setup. Based on the anharmonic cyclotron frequency determination method pioneered at the University of Washington, Seattle, precision at the level of 1 part in 10{sup 11} in the T/{sup 3}He mass ratio is expected. In this contribution, I describe the motivation, the principle, current status, and expectations of the experiment.

  9. High-pressure resistivity technique for quasi-hydrostatic compression experiments.

    Science.gov (United States)

    Rotundu, C R; Ćuk, T; Greene, R L; Shen, Z-X; Hemley, Russell J; Struzhkin, V V

    2013-06-01

    Diamond anvil cell techniques are now well established and powerful methods for measuring materials properties to very high pressure. However, high pressure resistivity measurements are challenging because the electrical contacts attached to the sample have to survive to extreme stress conditions. Until recently, experiments in a diamond anvil cell were mostly limited to non-hydrostatic or quasi-hydrostatic pressure media other than inert gases. We present here a solution to the problem by using focused ion beam ultrathin lithography for a diamond anvil cell loaded with inert gas (Ne) and show typical resistivity data. These ultrathin leads are deposited on the culet of the diamond and are attaching the sample to the anvil mechanically, therefore allowing for measurements in hydrostatic or nearly hydrostatic conditions of pressure using noble gases like Ne or He as pressure transmitting media.

  10. Test of Lorentz symmetry with a 3He/129Xe clock-comparison experiment

    International Nuclear Information System (INIS)

    Gemmel, Claudia

    2011-01-01

    The minimal Standard Model Extension (SME) of Kostelecky and coworkers, which parametrizes the general treatment of CPT- and Lorentz invariance violation, predicts sidereal modulations of atomic transition frequencies as the Earth rotates relative to a Lorentz-violating background field. One method to search for these modulations is the so-called clock-comparison experiment, where the frequencies of co-located clocks are compared as they rotate with respect to the fixed stars. In this work an experiment is presented where polarized 3 He and 129 Xe gas samples in a glass cell serve as clocks, whose nuclear spin precession frequencies are detected with the help of highly sensitive SQUID sensors inside a magnetically shielded room. The unique feature of this experiment is the fact that the spins are precessing freely, with transverse relaxation times T * 2 of up to 4.4 h for 129 Xe and 14.1 h for 3 He. To be sensitive to Lorentz-violating effects, the influence of external magnetic fields is canceled via the weighted 3 He/ 129 Xe phase difference, ΔΦ=Φ he -(γ he )/(γ xe ) Φ xe . The Lorentz-violating SME parameters for the neutron, b n X and b n Y , are determined out of a χ 2 fit on the phase difference data of 7 spin precession measurements of 12 to 16 hours length. The piecewise defined fit model contains a sine and a cosine term to describe the sidereal modulation, as well as 7 offset terms, 7 linear terms and 7 . 2 exponential terms decreasing with T * 2,he and T * 2,xe , which are assigned to the respective measurement. The linear term in the weighted phase difference mainly arises from deviations of the gyromagnetic ratios from their literature values due to chemical shifts, while the exponential terms reflect the phase shifts resulting from demagnetization fields in the non-ideally spherical sample cell. The result of the χ 2 fit constrains the parameter b n perpendicular to =√((b n X ) 2 +(b n Y ) 2 ) to be -32 GeV at the 95% confidence level. This

  11. Spin polarized deuterium

    International Nuclear Information System (INIS)

    Glyde, H.R.; Hernadi, S.I.

    1986-01-01

    Several ground state properties of (electron) spin-polarized deuterium (D) such as the energy, single quasiparticle energies and lifetimes, Landau parameters and sound velocities are evaluated. The calculations begin with the Kolos-Wolneiwicz potential and use the Galitskii-FeynmanHartree-Fock (GFHF) approximation. The deuteron nucleas has spin I = 1, and spin states I/sub z/ = 1,0,-1. We explore D 1 , D 2 and D 3 in which, respectively, one spin state only is populated, two states are equally populated, and three states are equally populated. We find the GFHF describes D 1 well, but D 2 and D 3 less well. The Landau parameters, F/sub L/, are small compared to liquid 3 He and very small for doubly polarized D 1 (i.e. the F/sub L/ decrease with nuclear polarization)

  12. Hydrostatic pressure mimics gravitational pressure in characean cells

    Science.gov (United States)

    Staves, M. P.; Wayne, R.; Leopold, A. C.

    1992-01-01

    Hydrostatic pressure applied to one end of a horizontal Chara cell induces a polarity of cytoplasmic streaming, thus mimicking the effect of gravity. A positive hydrostatic pressure induces a more rapid streaming away from the applied pressure and a slower streaming toward the applied pressure. In contrast, a negative pressure induces a more rapid streaming toward and a slower streaming away from the applied pressure. Both the hydrostatic pressure-induced and gravity-induced polarity of cytoplasmic streaming respond identically to cell ligation, UV microbeam irradiation, external Ca2+ concentrations, osmotic pressure, neutral red, TEA Cl-, and the Ca2+ channel blockers nifedipine and LaCl3. In addition, hydrostatic pressure applied to the bottom of a vertically-oriented cell can abolish and even reverse the gravity-induced polarity of cytoplasmic streaming. These data indicate that both gravity and hydrostatic pressure act at the same point of the signal transduction chain leading to the induction of a polarity of cytoplasmic streaming and support the hypothesis that characean cells respond to gravity by sensing a gravity-induced pressure differential between the cell ends.

  13. High-Pressure Single-Crystal Structures of 3D Lead-Halide Hybrid Perovskites and Pressure Effects on their Electronic and Optical Properties.

    Science.gov (United States)

    Jaffe, Adam; Lin, Yu; Beavers, Christine M; Voss, Johannes; Mao, Wendy L; Karunadasa, Hemamala I

    2016-04-27

    We report the first high-pressure single-crystal structures of hybrid perovskites. The crystalline semiconductors (MA)PbX3 (MA = CH3NH3 (+), X = Br(-) or I(-)) afford us the rare opportunity of understanding how compression modulates their structures and thereby their optoelectronic properties. Using atomic coordinates obtained from high-pressure single-crystal X-ray diffraction we track the perovskites' precise structural evolution upon compression. These structural changes correlate well with pressure-dependent single-crystal photoluminescence (PL) spectra and high-pressure bandgaps derived from density functional theory. We further observe dramatic piezochromism where the solids become lighter in color and then transition to opaque black with compression. Indeed, electronic conductivity measurements of (MA)PbI3 obtained within a diamond-anvil cell show that the material's resistivity decreases by 3 orders of magnitude between 0 and 51 GPa. The activation energy for conduction at 51 GPa is only 13.2(3) meV, suggesting that the perovskite is approaching a metallic state. Furthermore, the pressure response of mixed-halide perovskites shows new luminescent states that emerge at elevated pressures. We recently reported that the perovskites (MA)Pb(Br x I1-x )3 (0.2 < x < 1) reversibly form light-induced trap states, which pin their PL to a low energy. This may explain the low voltages obtained from solar cells employing these absorbers. Our high-pressure PL data indicate that compression can mitigate this PL redshift and may afford higher steady-state voltages from these absorbers. These studies show that pressure can significantly alter the transport and thermodynamic properties of these technologically important semiconductors.

  14. Characterization of highly scattering media by measurement of diffusely backscattered polarized light

    Science.gov (United States)

    Hielscher, Andreas H.; Mourant, Judith R.; Bigio, Irving J.

    2000-01-01

    An apparatus and method for recording spatially dependent intensity patterns of polarized light that is diffusely backscattered from highly scattering media are described. These intensity patterns can be used to differentiate different turbid media, such as polystyrene-sphere and biological-cell suspensions. Polarized light from a He-Ne laser (.lambda.=543 nm) is focused onto the surface of the scattering medium, and a surface area of approximately 4.times.4 cm centered on the light input point is imaged through polarization analysis optics onto a CCD camera. A variety of intensity patterns may be observed by varying the polarization state of the incident laser light and changing the analyzer configuration to detect different polarization components of the backscattered light. Experimental results for polystyrene-sphere and Intralipid suspensions demonstrate that the radial and azimuthal variations of the observed pattern depend on the concentration, size, and anisotropy factor, g, of the particles constituting the scattering medium. Measurements performed on biological cell suspensions show that intensity patterns can be used to differentiate between suspensions of cancerous and non-cancerous cells. Introduction of the Mueller-matrix for diffusely backscattered light, permits the selection of a subset of measurements which comprehensively describes the optical properties of backscattering media.

  15. Thermoset recycling via high-pressure high-temperature sintering: Revisiting the effect of interchange chemistry

    Science.gov (United States)

    Morin, Jeremy Edward

    In 1844 Charles Goodyear obtained U.S. Patent #3,633 for his "Gum Elastic Composition". In a published circular, which describes his patent for the sulfur vulcanization of gum elastic composition, he stated: "No degree of heat, without blaze, can melt it (rubber)... It resists the most powerful chemical reagents. Aquafortis (nitric acid), sulphuric acid, essential and common oils, turpentine and other solvents... ..." Goodyear's sulfur vulcanization of rubber fueled much of the industrial revolution and made transportation possible, as it exists today. In doing so, Goodyear created one of the most difficult materials to recycle. Rubber will not melt, dissolve, or lend itself to the usual methods of chemical decomposition. Ironically, Goodyear recognized this problem and in 1853 he patented the process of adding ground rubber to virgin material, now currently known as regrind blending. Today, scrap tires represent one of the most serious sources of pollution in the world. Studies estimate that there are roughly 2 billion scrap tires in U.S. landfills and more are being added at a rate of over 273 million tires per year. Current methods of recycling waste tires are crude, ineffective, and use rubber powder as a low cost filler instead of a new rubber. The groundwork for a very simple and effective method of producing high-quality rubber goods using 100% scrap rubber was discovered in 1944 by A. V. Tobolsky et al. This application, however, was not recognized until recently in our laboratory. The process as studied to date represents a method of creating quality, high-value added rubber goods with nothing other than heat and pressure. High pressure is required to obtain a void-free compaction of the rubber particles by forcing all of the free surfaces into intimate contact. High temperature then activates the chemical rearrangement, scission, and reformation of the chemical bonds thus providing new bridges between the once fractured interfaces. This occurs both within

  16. APT 3He target/blanket. Topical report

    International Nuclear Information System (INIS)

    1995-03-01

    The 3 He target/blanket (T/B) preconceptual design for the 3/8-Goal facility is based on a 1000-MeV, 200-mA accelerator to produce a high-intensity proton beam that is expanded and then strikes one of two T/B modules. Each module consists of a centralized neutron source made of tungsten and lead, a proton beam backstop region made of zirconium and lead, and a moderator made of D 2 O. Helium-3 gas is circulated through the neutron source region and the blanket to create tritium through neutron capture. The gas is continually processed to extract the tritium with an online separation process

  17. Pressure variation of Rashba spin splitting toward topological transition in the polar semiconductor BiTeI

    Science.gov (United States)

    Ideue, T.; Checkelsky, J. G.; Bahramy, M. S.; Murakawa, H.; Kaneko, Y.; Nagaosa, N.; Tokura, Y.

    2014-10-01

    BiTeI is a polar semiconductor with gigantic Rashba spin-split bands in bulk. We have investigated the effect of pressure on the electronic structure of this material via magnetotransport. Periods of Shubunikov-de Haas (SdH) oscillations originating from the spin-split outer Fermi surface and inner Fermi surface show disparate responses to pressure, while the carrier number derived from the Hall effect is unchanged with pressure. The associated parameters which characterize the spin-split band structure are strongly dependent on pressure, reflecting the pressure-induced band deformation. We find the SdH oscillations and transport response are consistent with the theoretically proposed pressure-induced band deformation leading to a topological phase transition. Our analysis suggests the critical pressure for the quantum phase transition near Pc=3.5 GPa.

  18. Effect of the potential well on low temperature pressure broadening in CO-He

    Science.gov (United States)

    Palma, A.; Green, S.

    1986-01-01

    Previously reported low-temperature pressure-broadening calculations (Green, 1985) for CO-He interacting via an SCF-CI potential are compared with new calculations in which the attractive part of the potential is either reduced by half or eliminated entirely. Results demonstrate that the attractive well is responsible for low-temperature enhancement of pressure-broadening cross sections and suggest that agreement with recent experimental values at 4 K (Messer and DeLucia, 1984) can be obtained by a modest reduction, probably within the expected uncertainty, in the attractive part of the SCF-CI potential.

  19. An apparatus for preparing isotopically pure He4

    International Nuclear Information System (INIS)

    McClintock, P.V.E.

    1978-01-01

    A cryostat has been constructed for extracting pure He 4 from He II of natural isotopic composition by means of a heat flush technique. It is shown that the method is in principle capable of yielding He 4 which is entirely devoid of He 3 isotopic impurities. A secondary heat flush, operated in conjunction with a conical heat exchanger of novel design, was used to place an experimental lower bound of 2 x 10 15 on the He 4 /He 3 ratio of the product, a standard sufficient for all present or projected applications requiring isotopically pure He 4 . The apparatus produces 2 000 1 (at standard temperature and pressure) of He 4 per thermal cycle. The design of future purifiers is discussed. (author)

  20. Radio polarization properties of quasars and active galaxies at high redshifts

    Science.gov (United States)

    Vernstrom, T.; Gaensler, B. M.; Vacca, V.; Farnes, J. S.; Haverkorn, M.; O'Sullivan, S. P.

    2018-04-01

    We present the largest ever sample of radio polarization properties for z > 4 sources, with 14 sources having significant polarization detections. Using wide-band data from the Karl G. Jansky Very Large Array, we obtained the rest-frame total intensity and polarization properties of 37 radio sources, nine of which have spectroscopic redshifts in the range 1 ≤ z ≤ 1.4, with the other 28 having spectroscopic redshifts in the range 3.5 ≤ z ≤ 6.21. Fits are performed for the Stokes I and fractional polarization spectra, and Faraday rotation measures are derived using rotation measure synthesis and QU fitting. Using archival data of 476 polarized sources, we compare high-redshift (z > 3) source properties to a 15 GHz rest-frame luminosity matched sample of low-redshift (z 3 sources and 57 ± 4 rad m-2 for z < 3. Although there is some indication of lower intrinsic rotation measures at high-z possibly due to higher depolarization from the high-density environments, using several statistical tests we detect no significant difference between low- and high-redshift sources. Larger samples are necessary to determine any true physical difference.