WorldWideScience

Sample records for high-precision systematic study

  1. High-precision Mg isotopic systematics of bulk chondrites

    Science.gov (United States)

    Schiller, Martin; Handler, Monica R.; Baker, Joel A.

    2010-08-01

    Variations of the mass-independent abundance of 26Mg ( δ26Mg*) and stable Mg ( δ25Mg) isotope composition of chondrites are important because they constrain the homogeneity of 26Al and Mg isotopes in the proto-planetary disc and the validity of the short-lived 26Al-to- 26Mg chronometer applied to meteorites. We present high-precision Mg isotope data and Al/Mg ratios of chondrites representing nearly all major chondrite classes, including a step-leaching experiment on the CM2 chondrite Murchison. δ26Mg* variations in leachates of Murchison representing acid soluble material are ≤ 30 times smaller than reported for neutron-rich isotopes of Ti and Cr and do not reveal resolvable deficits in δ26Mg* (-0.002 to + 0.118‰). Very small variations in δ26Mg* anomalies in bulk chondrites (-0.006 to + 0.019‰) correlate with increasing 27Al/ 24Mg ratios and δ50Ti, reflecting the variable presence of calcium-aluminium-rich inclusions (CAIs) in some types of carbonaceous chondrites. Similarly, release of radiogenic 26Mg produced by 26Al decay from CAI material in the step-leaching of Murchison best explains the high δ26Mg* observed in the last, aggressive, leaching steps of this experiment. Overall, the observed variations in δ26Mg* are small and potential differences beyond that which result from the presence of CAI-like material cannot be detected within the analytical uncertainties of this study (± 0.004‰). The results do not allow radical heterogeneity of 26Al (≥±30%) or measurable Mg nucleosynthetic heterogeneity (≥±0.005‰) to have existed on a planetesimal scale in the proto-planetary disc. Combined with published δ26Mg* data for CAIs, the bulk chondrite data yield a precise initial ( 26Al/ 27Al) 0 = (5.21 ± 0.06) × 10 -5 and δ26Mg* = -0.0340 ± 0.0016‰ for the Solar System. However, it is not possible with the currently available data to determine with certainty whether CAIs and the material from which planetesimals accreted including

  2. Some comments on high precision study of neutrino oscillations

    Science.gov (United States)

    Bilenky, S. M.

    2015-07-01

    I discuss here some problems connected with the high precision study of neutrino oscillations. In the general case of n-neutrino mixing I derive a convenient expression for transition probability in which only independent terms (and mass-squared differences) enter. For three-neutrino mixing I discuss a problem of a definition of a large (atmospheric) neutrino mass-squared difference. I comment also possibilities to reveal the character of neutrino mass spectrum in future reactor neutrino experiments.

  3. Resolving high precision U-Pb ages from Tertiary plutons with complex zircon systematics

    Science.gov (United States)

    Mcclelland, William C.; Mattinson, James M.

    1996-10-01

    Success in establishing high precision crystallization ages with the U/Pb zircon method is highly dependent on the ability to isolate or remove the effects of inherited xenocrystic components or secondary lead-loss, or the combined effects of both. Current "conventional" single crystal and ion probe (SHRIMP) methods are successfully applied to Paleozoic and older samples but typically suffer from imprecision when applied to younger (Mesozoic-Cenozoic) samples due to generally reduced radiogenic lead concentrations. Here we apply a series of intense partial dissolution steps to multigrain zircon fractions from a series of Paleocene tonalitic to granodioritic intrusive rocks from southeastern Alaska. The zircon systematics are complicated by both minor inheritance and postcrystallization lead-loss. Physical and isotopic evidence demonstrate that the partial dissolution steps preferentially remove outer layers susceptible to lead loss, as well as core regions containing inherited components. The final residues are often hollow shells of low-U primary igneous zircon that yield highly precise, reproducible, and concordant ages. The resulting age determinations commonly statistically differ at the 95% confidence level from ages based on apparently concordant, but less precise conventional isotope dilution analyses, the uncertainties of which masked minor, subtle isotopic complexities. This observation strongly cautions against basing age assignments of samples yielding slightly discordant data on (1) single "concordant" analyses accompanied by an array of discordant data or (2) the mean of several 206Pb/ 238U or 207Pb/ 206Pb ages. The step-wise dissolution technique allows age determinations on young, relatively low U and Pb zircons at a resolution not currently possible with techniques such as single-grain conventional or spot ion probe analyses. Widespread application of the technique will likely prove instrumental in resolving detailed magmatic histories of igneous

  4. A Study of Particle Beam Spin Dynamics for High Precision Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Fiedler, Andrew J. [Northern Illinois Univ., DeKalb, IL (United States)

    2017-05-01

    In the search for physics beyond the Standard Model, high precision experiments to measure fundamental properties of particles are an important frontier. One group of such measurements involves magnetic dipole moment (MDM) values as well as searching for an electric dipole moment (EDM), both of which could provide insights about how particles interact with their environment at the quantum level and if there are undiscovered new particles. For these types of high precision experiments, minimizing statistical uncertainties in the measurements plays a critical role. \\\\ \\indent This work leverages computer simulations to quantify the effects of statistical uncertainty for experiments investigating spin dynamics. In it, analysis of beam properties and lattice design effects on the polarization of the beam is performed. As a case study, the beam lines that will provide polarized muon beams to the Fermilab Muon \\emph{g}-2 experiment are analyzed to determine the effects of correlations between the phase space variables and the overall polarization of the muon beam.

  5. Study of highly precise outdoor characterization technique for photovoltaic modules in terms of reproducibility

    Science.gov (United States)

    Fukabori, Akihiro; Takenouchi, Takakazu; Matsuda, Youji; Tsuno, Yuki; Hishikawa, Yoshihiro

    2015-08-01

    In this study, novel outdoor measurements were conducted for highly precise characterization of photovoltaic (PV) modules by measuring current-voltage (I-V) curves with fast sweep speeds and module’s temperature, and with a PV sensor for reference. Fast sweep speeds suppressed the irradiance variation. As a result, smooth I-V curves were obtained and the PV parameter deviation was suppressed. The module’s temperature was measured by attaching resistive temperature detector sensors on the module’s backsheet. The PV sensor was measured synchronously with the PV module. The PV parameters including Isc, Pmax, Voc, and FF were estimated after correcting the I-V curves using the IEC standards. The reproducibility of Isc, Pmax, Voc, and FF relative to the outdoor fits was evaluated as 0.43, 0.58, 0.24, and 0.23%, respectively. The results demonstrate that highly precise measurements are possible using a PV measurement system with the three above-mentioned features.

  6. Flow-Based Systems for Rapid and High-Precision Enzyme Kinetics Studies

    Directory of Open Access Journals (Sweden)

    Supaporn Kradtap Hartwell

    2012-01-01

    Full Text Available Enzyme kinetics studies normally focus on the initial rate of enzymatic reaction. However, the manual operation of steps of the conventional enzyme kinetics method has some drawbacks. Errors can result from the imprecise time control and time necessary for manual changing the reaction cuvettes into and out of the detector. By using the automatic flow-based analytical systems, enzyme kinetics studies can be carried out at real-time initial rate avoiding the potential errors inherent in manual operation. Flow-based systems have been developed to provide rapid, low-volume, and high-precision analyses that effectively replace the many tedious and high volume requirements of conventional wet chemistry analyses. This article presents various arrangements of flow-based techniques and their potential use in future enzyme kinetics applications.

  7. A study on using image serving technology for high precision mechanical positioning

    Science.gov (United States)

    Lin, Chuen-Horng; Hsiao, Muh-Don; Lai, Kuo-Jung

    2016-12-01

    This paper focused on using image server technology for high precision mechanical positioning. Rapid and precise positioning systems depend on the correct positions of CCD (Charge Coupled Device) video cameras, as well as on pattern matching modes. This study deals with four different positions captured by an automatic detection system employing a CCD video camera. According to a variety of hybrid image registration systems, this study proposes an entire set of methods for achieving optimal hybrid pattern matching. First, the four different position detections captured by the CCD video camera in low-resolution were examined. Next, the original position detection was carried out in high-resolution, in order to derive a precise set of CCD video camera positions. The fiducial mark (FM) was then divided into two types in the optimal option for pattern matching: the "fiducial mark" and "non-fiducial mark", which were then used for sampling. The automatic detection method is able to achieve the first pattern matching detection for recognized images. Unrecognized images or images that cannot have an FM were subjected to fine pattern matching detection. When it is not possible to find more than one FM after the proposed detection method, this suggests that the position of the CCD video camera should be reset. In this paper, the results of the experiment regarding the CCD camera precision location and the segmentation of fiducial patterns or insignificant fiducial patterns can detect and segment more unique areas and areas with unique features.

  8. The study about forming high-precision optical lens minimalized sinuous error structures for designed surface

    Science.gov (United States)

    Katahira, Yu; Fukuta, Masahiko; Katsuki, Masahide; Momochi, Takeshi; Yamamoto, Yoshihiro

    2016-09-01

    Recently, it has been required to improve qualities of aspherical lenses mounted on camera units. Optical lenses in highvolume production generally are applied with molding process using cemented carbide or Ni-P coated steel, which can be selected from lens material such as glass and plastic. Additionally it can be obtained high quality of the cut or ground surface on mold due to developments of different mold product technologies. As results, it can be less than 100nmPV as form-error and 1nmRa as surface roughness in molds. Furthermore it comes to need higher quality, not only formerror( PV) and surface roughness(Ra) but also other surface characteristics. For instance, it can be caused distorted shapes at imaging by middle spatial frequency undulations on the lens surface. In this study, we made focus on several types of sinuous structures, which can be classified into form errors for designed surface and deteriorate optical system performances. And it was obtained mold product processes minimalizing undulations on the surface. In the report, it was mentioned about the analyzing process by using PSD so as to evaluate micro undulations on the machined surface quantitatively. In addition, it was mentioned that the grinding process with circumferential velocity control was effective for large aperture lenses fabrication and could minimalize undulations appeared on outer area of the machined surface, and mentioned about the optical glass lens molding process by using the high precision press machine.

  9. Study of the data taking strategy for a high precision τ mass measurement

    Institute of Scientific and Technical Information of China (English)

    WANG You-Kai; ZHANG Jian-Yong; MO Xiao-Hu; YUAN Chang-Zheng

    2009-01-01

    To achieve a high precision τ mass measurement at the high luminosity experiment BESⅢ, Monte Carlo simulation and sampling technique are utilized to simulate various data taking cases for single and multi-parameter fits by virtue of which the optimal scheme is determined. The optimized proportion of luminosity distributed at selected points and the relation between precision and luminosity are obtained. In addition, the optimization of the fit scheme is confirmed by scrutinizing a variety of fit possibilities.

  10. Studies on fast timing and high precision tracking performance of Resistive Plate Chamber

    CERN Document Server

    Han, L; The ATLAS collaboration

    2013-01-01

    Resistive plate chambers (RPC), produced in large scales, are widely used as trigger detectors with O(ns) time resolution in high energy and high intensity experiments. To confront the future high experimental frontiers, such as the super-LHC, RPCs equipped with fine-pitch readout strips were tested with 180GeV/c muon at CERN SPS H8 beam line, to assess the viability of using RPCs for both fast timing and high precision tracking trigger.

  11. Overview of the JYFLTRAP mass measurements and high-precision -values for weak interaction studies

    Indian Academy of Sciences (India)

    T Eronen; Jyfltrap

    2010-08-01

    The JYFLTRAP Penning trap set-up at the University of Jyväskylä, Finland, is a Penning trap facility that has provided high-precision atomic mass values for short-lived nuclides since 2003. Until now, masses of more than 250 short-lived nuclides have been measured. Since JYFLTRAP is coupled to the chemically insensitive IGISOL mass separator, any element can be accessed. So far, a huge mass surface extending from magnesium ( = 12) to lead ( = 82) has been covered.

  12. High Precision Thermal Ionization Mass Spectrometric Dating of Corals and Its Application to Paleo—Environmental Study

    Institute of Scientific and Technical Information of China (English)

    王兆荣; 张兆峰; 等

    2001-01-01

    Global change has become a hot spot in Quaternary geology,and high-precision,high-sensitivity dating is also an urgent problem which needs to be solved.This paper presents some achievements in U-servies dating of marine corals by thermal ionization mass spectrometry (TIMS) and its application to the study of paleo-environments.Recently,coral samples were determined for their ages on a MAT-262 mass spectrometer and satisfactory results have been obtained.

  13. High Precision Thermal Ionization Mass Spectrometric Dating of Corals and Its Application to Paleo-Environmental Study

    Institute of Scientific and Technical Information of China (English)

    王兆荣; 张兆峰; 彭子成; 马志邦

    2001-01-01

    Global change has become a hot spot in Quaternary geology, and high-precision,high-sensitivity dating is also an urgent problem which needs to be solved. This paper presents some achievements in U-series dating of marine corals by thermal ionization mass spectrometry (TIMS) and its application to the study of paleo-environments. Recently, coral samples were determined for their ages on a MAT-262 mass spectrometer and satisfactory results have been obtained.

  14. Neoarchean metamorphism recorded in high-precision Sm-Nd isotope systematics of garnets from the Jack Hills (Western Australia)

    Science.gov (United States)

    Eccles, K. A.; Baxter, E. F.; Mojzsis, S. J.; Marschall, H.; Williams, M. L.; Jercinovic, M. J.

    2013-12-01

    Studies of metasedimentary rocks from the Jack Hills, which host Earth's oldest known detrital minerals, have focused on zircon and occasionally monazite or xenotime, but no attention has been directed toward one of the most common mineral markers of metamorphism: garnet. Garnet can provide a record of the post-depositional, prograde metamorphic history of Archean metasedimentary rocks. Additionally, the use of a newly developed detrital garnet dating technique [1,2] may reveal information about pre-depositional metamorphism that could address lingering questions about the nature and timing of Earth's earliest tectonometamorphic events. Here we investigate garnet from the Jack Hills metasedimentary rocks to test whether they record in situ metamorphism or are a detrital relict of even older metamorphic events. We identified garnet in two bulk quartz-pebble conglomerate samples collected from the 'discovery' outcrop at Eranondoo Hill in the Jack Hills of Western Australia. Electron microprobe analyses of polished grains and SEM measurements of unpolished grain surfaces are consistent, revealing garnet composition indicative of a single generation/population of predominantly almandine-spessartine solid solution (~10-35% mole fraction spessartine). Compositional maps of garnet grains reveal little zoning and no discontinuities, most consistent with a single growth event. Dating Jack Hills' garnet via the Sm-Nd system is possible due to continued development of small sample analysis techniques, including running NdO+ TIMS analyses with Ta2O5 activator [3] permitting nondestructive chemical prescreening technique (tabletop SEM) allows for grouping of multiple grains based on chemical similarity. Final Nd loads in the 450-750pg range routinely yield dates with precisions <×10Ma for two point isochrons between clean garnet (Sm/Nd ≥ 1.0) and their leached inclusion populations [2]. Four grouped garnet grain separates from one sample yield preliminary dates of 2703.6×6

  15. Study on the high-precision laser welding technology of nuclear fuel elements processing

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Sung; Yang, M. S.; Kim, W. K.; Lee, D. Y

    2001-01-01

    The proper welding method for appendage of bearing pads and spacers of PHWR nuclear fuel elements is considered important in respect to the soundness of weldments and the improvement of the performance of nuclear fuels during the operation in reactor. The probability of welding defects of the appendage parts is mostly apt to occur and it is connected directly with the safty and life prediction of the nuclear reactor in operation. Recently there has been studied all over the world to develope welding technology by laser in nuclear fuel processing, and the appendage of bearing pads and spacers of PHWR nuclear fuel elements. Therefore, the purpose of this study is to investigate the characteristics of the laser welded specimens and make some samples for the appendage of bearing pads of PHWR nuclear fuel elements. This study will be also provide the basic data for the fabrications of the appendage of bearing pads and spacers. Especially the laser welding is supposed to be used in the practical application such as precise materials manufacturing fields. In this respect this technology is not only a basic advanced technology with wide applications but also likely to be used for the development of directly applicable technologies for industries, with high potential benefits derived in the view point of economy and industry.

  16. Using Pharmacological Manipulation and High-precision Radio Telemetry to Study the Spatial Cognition in Free-ranging Animals.

    Science.gov (United States)

    Roth, Timothy C; Krochmal, Aaron R; Gerwig, William B; Rush, Sage; Simmons, Nathaniel T; Sullivan, Jeffery D; Wachter, Katrina

    2016-11-06

    An animal's ability to perceive and learn about its environment plays a key role in many behavioral processes, including navigation, migration, dispersal and foraging. However, the understanding of the role of cognition in the development of navigation strategies and the mechanisms underlying these strategies is limited by the methodological difficulties involved in monitoring, manipulating the cognition of, and tracking wild animals. This study describes a protocol for addressing the role of cognition in navigation that combines pharmacological manipulation of behavior with high-precision radio telemetry. The approach uses scopolamine, a muscarinic acetylcholine receptor antagonist, to manipulate cognitive spatial abilities. Treated animals are then monitored with high frequency and high spatial resolution via remote triangulation. This protocol was applied within a population of Eastern painted turtles (Chrysemys picta) that has inhabited seasonally ephemeral water sources for ~100 years, moving between far-off sources using precise (± 3.5 m), complex (i.e., non-linear with high tortuosity that traverse multiple habitats), and predictable routes learned before 4 years of age. This study showed that the processes used by these turtles are consistent with spatial memory formation and recall. Together, these results are consistent with a role of spatial cognition in complex navigation and highlight the integration of ecological and pharmacological techniques in the study of cognition and navigation.

  17. Feasibility study of performing high precision gamma spectroscopy of {lambda}{lambda} hypernuclei in the anti PANDA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Lorente, Alicia

    2010-09-30

    Hypernuclear research will be one of the main topics addressed by the anti PANDA experiment at the planned Facility for Antiproton and Ion Research anti FAIR. Thanks to the use of stored anti p beams, copious production of double {lambda} hypernuclei is expected at the anti PANDA experiment, which will enable high precision {gamma} spectroscopy of such nuclei for the first time. At anti PANDA excited states of {xi}{sup -} hypernuclei will be used as a basis for the formation of double {lambda} hypernuclei. For their detection, a devoted hypernuclear detector setup is planned. This setup consists of a primary nuclear target for the production of {xi}{sup -}+ anti {xi} pairs, a secondary active target for the hypernuclei formation and the identification of associated decay products and a germanium array detector to perform {gamma} spectroscopy. In the present work, the feasibility of performing high precision {gamma} spectroscopy of double {lambda} hypernuclei at the anti PANDA experiment has been studied by means of a Monte Carlo simulation. For this issue, the designing and simulation of the devoted detector setup as well as of the mechanism to produce double {lambda} hypernuclei have been optimized together with the performance of the whole system. In addition, the production yields of double hypernuclei in excitedparticle stable states have been evaluated within a statistical decay model. A strategy for the unique assignment of various newly observed {gamma}-transitions to specific double hypernuclei has been successfully implemented by combining the predicted energy spectra of each target with the measurement of two pion momenta from the subsequent weak decays of a double hypernucleus. Indeed, based on these Monte Carlo simulation, the analysis of the statistical decay of {sup 13}{sub {lambda}}{sub {lambda}}B has been performed. As result, three {gamma}-transitions associated to the double hypernuclei {sup 11}{sub {lambda}}{sub {lambda}}Be and to the single

  18. Oxygen isotope systematics of chondrules in the Allende CV3 chondrite: High precision ion microprobe studies

    Digital Repository Service at National Institute of Oceanography (India)

    Rudraswami, N.G.; Ushikubo, T.; Nakashima, D.; Kita, N.T.

    chondrules range from -5 ppt to 0 ppt, indicating that not all BO chondrules plot near the terrestrial fractionation line as suggested by previous bulk chondrule analyses. Based on these data, we suggest the presence of multiple oxygen isotope reservoirs...

  19. High Precision Electon Beam Polarimetry

    National Research Council Canada - National Science Library

    Dutta, D

    2016-01-01

    Over the last three decades high precision electron beam polarimetry has been at the fore-front of progress made in leveraging the spin degrees of freedom in nuclear and particle physics experiments...

  20. A high precision gas flow cell for performing in situ neutron studies of local atomic structure in catalytic materials

    Science.gov (United States)

    Olds, Daniel; Page, Katharine; Paecklar, Arnold; Peterson, Peter F.; Liu, Jue; Rucker, Gerald; Ruiz-Rodriguez, Mariano; Olsen, Michael; Pawel, Michelle; Overbury, Steven H.; Neilson, James R.

    2017-03-01

    Gas-solid interfaces enable a multitude of industrial processes, including heterogeneous catalysis; however, there are few methods available for studying the structure of this interface under operating conditions. Here, we present a new sample environment for interrogating materials under gas-flow conditions using time-of-flight neutron scattering under both constant and pulse probe gas flow. Outlined are descriptions of the gas flow cell and a commissioning example using the adsorption of N2 by Ca-exchanged zeolite-X (Na78-2xCaxAl78Si144O384,x ≈ 38). We demonstrate sensitivities to lattice contraction and N2 adsorption sites in the structure, with both static gas loading and gas flow. A steady-state isotope transient kinetic analysis of N2 adsorption measured simultaneously with mass spectrometry is also demonstrated. In the experiment, the gas flow through a plugged-flow gas-solid contactor is switched between 15N2 and 14N2 isotopes at a temperature of 300 K and a constant pressure of 1 atm; the gas flow and mass spectrum are correlated with the structure factor determined from event-based neutron total scattering. Available flow conditions, sample considerations, and future applications are discussed.

  1. Very high precision and accuracy analysis of triple isotopic ratios of water. A critical instrumentation comparison study.

    Science.gov (United States)

    Gkinis, Vasileios; Holme, Christian; Morris, Valerie; Thayer, Abigail Grace; Vaughn, Bruce; Kjaer, Helle Astrid; Vallelonga, Paul; Simonsen, Marius; Jensen, Camilla Marie; Svensson, Anders; Maffrezzoli, Niccolo; Vinther, Bo; Dallmayr, Remi

    2017-04-01

    We present a performance comparison study between two state of the art Cavity Ring Down Spectrometers (Picarro L2310-i, L2140-i). The comparison took place during the Continuous Flow Analysis (CFA) campaign for the measurement of the Renland ice core, over a period of three months. Instant and complete vaporisation of the ice core melt stream, as well as of in-house water reference materials is achieved by accurate control of microflows of liquid into a homemade calibration system by following simple principles of the Hagen-Poiseuille law. Both instruments share the same vaporisation unit in a configuration that minimises sample preparation discrepancies between the two analyses. We describe our SMOW-SLAP calibration and measurement protocols for such a CFA application and present quality control metrics acquired during the full period of the campaign on a daily basis. The results indicate an unprecedented performance for all 3 isotopic ratios (δ2H, δ17O, δ18O ) in terms of precision, accuracy and resolution. We also comment on the precision and accuracy of the second order excess parameters of HD16O and H217O over H218O (Dxs, Δ17O ). To our knowledge these are the first reported CFA measurements at this level of precision and accuracy for all three isotopic ratios. Differences on the performance of the two instruments are carefully assessed during the measurement and reported here. Our quality control protocols extend to the area of low water mixing ratios, a regime in which often atmospheric vapour measurements take place and Cavity Ring Down Analysers show a poorer performance due to the lower signal to noise ratios. We address such issues and propose calibration protocols from which water vapour isotopic analyses can benefit from.

  2. Surface texture metrology for high precision surfaces

    DEFF Research Database (Denmark)

    Hansen, Hans Nørgaard; Gasparin, Stefania; Tosello, Guido

    2010-01-01

    This paper introduces some of the challenges related to surface texture measurement of high precision surfaces. The paper is presenting two case studies related to polished tool surfaces and micro part surfaces. In both cases measuring instrumentation, measurement procedure and the measurement...

  3. Surface texture metrology for high precision surfaces

    DEFF Research Database (Denmark)

    Hansen, Hans Nørgaard; Gasparin, Stefania; Tosello, Guido

    2010-01-01

    This paper introduces some of the challenges related to surface texture measurement of high precision surfaces. The paper is presenting two case studies related to polished tool surfaces and micro part surfaces. In both cases measuring instrumentation, measurement procedure and the measurement re...

  4. High precision, continuous measurements of water vapor isotopes using a field deployable analyzer with a novel automated calibration system to facilitate ecohydrological studies

    Science.gov (United States)

    Gupta, P.; Crosson, E.; Richman, B. A.; Apodaca, R. L.; Green, I.

    2009-12-01

    The use of stable isotopic analysis techniques has proved quite valuable in establishing links between ecology and hydrology. We present an alternative and novel approach to isotope ratio mass spectrometry (IRMS) for making high-precision D/H and 18O/16O isotope ratio measurements of water vapor at a field site using wavelength-scanned cavity ring-down spectroscopy (WS-CRDS) based technology. This WS-CRDS analyzer allows continuous real-time measurements of water vapor with automated periodic calibration using liquid standards, needing no human intervention for weeks during deployment. The new automated calibration system, designed specifically for field deployment, uses syringe pumps and is robust, consistent and reliable. The advanced temperature and pressure control within the analyzer are some of the key design features that allow high precision (0.2‰ for δ18O and 1.0‰ for δD) performance at extremely low drift (water vapor analyzer, a field trial was conducted where the common isotopologues of water vapor were measured at a local ecological site over a period of a few days. The resulting high resolution data gives us the ability to understand the impact of meteorology and plant physiology on the isotopic composition of water vapor in ambient air. Such measurements of water vapor, when combined with measurements of the isotopic composition of liquid water in plants, soil water and local water bodies, will close the eco-hydrological loop of any region. The ability of the WS-CRDS analyzer to make continuous, real-time measurements with a resolution on the order of a few seconds will aid in understanding the complex interdependencies between ecological and hydrological processes and will provide critical information in refining existing models of water transport in ecosystems. These studies are critical to understanding the impact of global climate change on landscapes.

  5. The PLATO End-to-End CCD Simulator -- Modelling space-based ultra-high precision CCD photometry for the assessment study of the PLATO Mission

    CERN Document Server

    Zima, W; De Ridder, J; Salmon, S; Catala, C; Kjeldsen, H; Aerts, C

    2010-01-01

    The PLATO satellite mission project is a next generation ESA Cosmic Vision satellite project dedicated to the detection of exo-planets and to asteroseismology of their host-stars using ultra-high precision photometry. The main goal of the PLATO mission is to provide a full statistical analysis of exo-planetary systems around stars that are bright and close enough for detailed follow-up studies. Many aspects concerning the design trade-off of a space-based instrument and its performance can best be tackled through realistic simulations of the expected observations. The complex interplay of various noise sources in the course of the observations made such simulations an indispensable part of the assessment study of the PLATO Payload Consortium. We created an end-to-end CCD simulation software-tool, dubbed PLATOSim, which simulates photometric time-series of CCD images by including realistic models of the CCD and its electronics, the telescope optics, the stellar field, the pointing uncertainty of the satellite ...

  6. High precision radial velocities with GIANO spectra

    CERN Document Server

    Carleo, I; Gratton, R; Benatti, S; Bonavita, M; Oliva, E; Origlia, L; Desidera, S; Claudi, R; Sissa, E

    2016-01-01

    Radial velocities (RV) measured from near-infrared (NIR) spectra are a potentially excellent tool to search for extrasolar planets around cool or active stars. High resolution infrared (IR) spectrographs now available are reaching the high precision of visible instruments, with a constant improvement over time. GIANO is an infrared echelle spectrograph at the Telescopio Nazionale Galileo (TNG) and it is a powerful tool to provide high resolution spectra for accurate RV measurements of exoplanets and for chemical and dynamical studies of stellar or extragalactic objects. No other high spectral resolution IR instrument has GIANO's capability to cover the entire NIR wavelength range (0.95-2.45 micron) in a single exposure. In this paper we describe the ensemble of procedures that we have developed to measure high precision RVs on GIANO spectra acquired during the Science Verification (SV) run, using the telluric lines as wavelength reference. We used the Cross Correlation Function (CCF) method to determine the v...

  7. Application of high-precision 3D seismic technology to shale gas exploration: A case study of the large Jiaoshiba shale gas field in the Sichuan Basin

    Directory of Open Access Journals (Sweden)

    Zuqing Chen

    2016-03-01

    Full Text Available The accumulation pattern of the marine shale gas in South China is different from that in North America. The former has generally thin reservoirs and complex preservation conditions, so it is difficult to make a fine description of the structural features of shale formations and to reflect accurately the distribution pattern of high-quality shale by using the conventional 2D and 3D seismic exploration technology, which has an adverse effect on the successful deployment of horizontal wells. In view of this, high-precision 3D seismic prospecting focusing on lithological survey was implemented to make an accurate description of the distribution of shale gas sweet spots so that commercial shale gas production can be obtained. Therefore, due to the complex seismic geological condition of Jiaoshiba area in Fuling, SE Sichuan Basin, the observation system of high-precision 3D seismic acquisition should have such features as wide-azimuth angles, small trace intervals, high folds, uniform vertical and horizontal coverage and long spread to meet the needs of the shale gas exploration in terms of structural interpretation, lithological interpretation and fracture prediction. Based on this idea, the first implemented high-precision 3D seismic exploration project in Jiaoshiba area played an important role in the discovery of the large Jiaoshiba shale gas field. Considering that the high-quality marine shale in the Sichuan Basin shows the characteristics of multi-layer development from the Silurian system to the Cambrian system, the strategy of shale gas stereoscopic exploration should be implemented to fully obtain the oil and gas information of the shallow, medium and deep strata from the high-precision 3D seismic data, and ultimately to expand the prospecting achievements in an all-round way to balance the high upstream exploration cost, and to continue to push the efficient shale gas exploration and development process in China.

  8. Adaptive Iterative Learning Control for High Precision Motion Systems

    NARCIS (Netherlands)

    Rotariu, I.; Steinbuch, M.; Ellenbroek, R.

    2008-01-01

    Iterative learning control (ILC) is a very effective technique to reduce systematic errors that occur in systems that repetitively perform the same motion or operation. However, several characteristics have prevented standard ILC from being widely used for high precision motion systems. Most importa

  9. Digitalization of highly precise fluxgate magnetometers

    DEFF Research Database (Denmark)

    Cerman, Ales; Kuna, A.; Ripka, P.

    2005-01-01

    This paper describes the theory behind all three known ways of digitalizing the fluxgate magnetometers: analogue magnetometers with digitalized output using high resolution ADC, application of the delta-sigma modulation to the sensor feedback loop and fully digital signal detection. At present time...... the Delta-Sigma ADCs are mostly used for the digitalization of the highly precise fluxgate magnetorneters. The relevant part of the paper demonstrates some pitfalls of their application studied during the design of the magnetometer for the new Czech scientific satellite MIMOSA. The part discussing...... the application of the A-E modulation to the sensor feedback loop theoretically derives the main advantage of this method-increasing of the modulation order and shows its real potential compared to the analog magnetometer with consequential digitalization. The comparison is realized on the modular magnetometer...

  10. Digitalization of highly precise fluxgate magnetometers

    DEFF Research Database (Denmark)

    Cerman, Ales; Kuna, A.; Ripka, P.

    2005-01-01

    allowing configurations with modulator inside and outside the feedback loop. The last principle is demonstrated on the project of the fully digital fluxgate magnetometer based on the digital signal processor (DSP). The results of the presented projects are compared with recently published competitive......This paper describes the theory behind all three known ways of digitalizing the fluxgate magnetometers: analogue magnetometers with digitalized output using high resolution ADC, application of the delta-sigma modulation to the sensor feedback loop and fully digital signal detection. At present time...... the Delta-Sigma ADCs are mostly used for the digitalization of the highly precise fluxgate magnetorneters. The relevant part of the paper demonstrates some pitfalls of their application studied during the design of the magnetometer for the new Czech scientific satellite MIMOSA. The part discussing...

  11. Study of High Precision Dynamic Initial Alignment Technology for Inertial Navigation System%惯导系统高精度动态对准技术研究

    Institute of Scientific and Technical Information of China (English)

    先治文; 胡小平; 练军想; 李冠南

    2013-01-01

    惯性导航初始对准技术是惯性导航的关键技术之一,而动态对准技术可以增强惯导系统的环境适应性.就GPS位置信息辅助下的惯性导航系统高精度动态对准技术进行研究.首先构建了15状态的Kalman滤波器,分析验证了Kalman滤波参数对于对准精度和对准速度的影响,在一定范围内,适当调整滤波参数,可以较好地改善滤波性能;然后在对准过程中使用了两位置转动观测增强的方法,提高了系统可观性,正确地估计比传感器件的零偏误差,并在纯惯导中加以补偿;最后通过跑车实验进行行车动态对准,达到了对准后24h纯惯导定位误差优于1 nmil的精度.%Inertial navigation is a process of integration, the main task of initial alignment of inertial navigation is determine the initial values of the integration and gyro drift errors and accelerometer biases. The initial alignment is one of the key technique of inertial navigation , in which dynamic initial alignment can improve the application of inertial navigation. In the paper, a high precision dynamic initial alignment technique is proposed for the GPS aided inertial navigation system (INS) on the moving base. This paper proposes the Kalman filter of 15 states, analyzes the effects of the Kalman parameters on the alignment accuracy and speed, showes that it will improve the performace of the filter that changing the Kalman paramaters properly. On the other hand, this paper uses the two-position a-lignment to improve the observability of the system, estimated the sensor-errores correctly then compensated them in the process of inertial navigation. Finally, the field-test used the high precision dynamic initial alignment technique, and the position error of navigation o-vermatch 1 nmile for 24 hours navigation.

  12. 基于ANFIS高精度光照度计的仿真研究%The Simulation Study of High-precision Light Illuminometer Based on ANFIS

    Institute of Scientific and Technical Information of China (English)

    张洋; 王鑫

    2011-01-01

    为提高光照度计的检测精度,针对光照度检测系统,应用Takagi-Sugeno模型的自适应神经模糊推理方法(ANFIS)到光照度检测系统,对光照度检测电路进行了误差补偿,并给出了硅光电池高精度光照度计的软件仿真.最后利用光照度检测实验平台实测数据作为样本数据,在MATLAB软件下的仿真结果表明:自适应神经模糊推理方法通过自学习,可以调整模糊规则和隶属函数参数,提高了光照度计的检测精度.%To improve the detecting precision of light illuminometer, for the illumination detection system, Takagi-Sugeno model of Adaptive Neural-Fuzzy Inference System( ANFIS) is applied, compensated the error of illumination detection circuits, and introduced software simulation of silicon-photocell high-precision light illuminometer. Finally, using measured data of the light test platform as the sample data, the MATLAB software simulation results show that: Adaptive Neural-Fuzzy Inference System through self-learning , can automatically adjust membership function parameters and the fuzzy rules, improves the precision of illumination detection.

  13. 高精度零磁通电流传感器的研究%Study on high-precision current sensor with zero flux

    Institute of Scientific and Technical Information of China (English)

    张振洪; 赵有俊

    2009-01-01

    The measurement accuracy of common current sensor is only 3 %~5 % and it is difficult to meet the needs of high-precision measurement. Through the error analysis of current sensor, the electronic circuit is added to the common current sensor to track the magnetizing current of iron core and compensate it dynamically,so that the iron core can achieve "zero flux" state. The working principle of current sensor by adding electronic compensation circuit,the structure of electronic circuit and the selection method of parameters in circuit are analyzed. The material and structure of iron core and shielding method of current sensor are also analyzed. The performance test shows that the accuracy of current sensor is improved and the compensation effect is good.%普通电流传感器的测量精度只有3%~5%,难以满足高精度测量的需要.通过对电流传感器误差的分析,在普通电流传感器的基础上,加入电子线路动态跟踪铁芯中的激磁电流并进行补偿,使铁芯动态地达到"零磁通"状态.分析了加入电子补偿线路后电流传感器的工作原理、电子线路的结构与线路中参数的确定方法,并对铁芯的材料、结构与屏蔽等做了分析.测试表明:电流传感器的精度得到了提高,补偿效果良好.

  14. High-precision astrometry towards ELTs

    CERN Document Server

    Massari, Davide; Tolstoy, Eline; McConnachie, Alan; Stuik, Remko; Schreiber, Laura; Andersen, David; Clénet, Yann; Davies, Richard; Gratadour, Damien; Kuijken, Konrad; Navarro, Ramon; Pott, Jörg-Uwe; Rodeghiero, Gabriele; Turri, Paolo; Kleijn, Gijs Verdoes

    2016-01-01

    With the aim of paving the road for future accurate astrometry with MICADO at the European-ELT, we performed an astrometric study using two different but complementary approaches to investigate two critical components that contribute to the total astrometric accuracy. First, we tested the predicted improvement in the astrometric measurements with the use of an atmospheric dispersion corrector (ADC) by simulating realistic images of a crowded Galactic globular cluster. We found that the positional measurement accuracy should be improved by up to ~2 mas with the ADC, making this component fundamental for high-precision astrometry. Second, we analysed observations of a globular cluster taken with the only currently available Multi-Conjugate Adaptive Optics assisted camera, GeMS/GSAOI at Gemini South. Making use of previously measured proper motions of stars in the field of view, we were able to model the distortions affecting the stellar positions. We found that they can be as large as ~200 mas, and that our bes...

  15. High precision {sup 14}C AMS at CIRCE

    Energy Technology Data Exchange (ETDEWEB)

    Terrasi, Filippo [Dipartimento di Scienze Ambientali, II Universita di Napoli, Via Vivaldi 43, Caserta 81100 (Italy); CIRCE, INNOVA, Via Campi Flegrei 34, Pozzuoli 80078 (Italy)], E-mail: filippo.terrasi@unina2.it; De Cesare, Nicola [Dipartimento di Scienze della Vita, II Universita di Napoli, Via Vivaldi 43, Caserta 81100 (Italy); CIRCE, INNOVA, Via Campi Flegrei 34, Pozzuoli 80078 (Italy); D' Onofrio, Antonio; Lubritto, Carmine; Marzaioli, Fabio [Dipartimento di Scienze Ambientali, II Universita di Napoli, Via Vivaldi 43, Caserta 81100 (Italy); CIRCE, INNOVA, Via Campi Flegrei 34, Pozzuoli 80078 (Italy); Passariello, Isabella [CIRCE, INNOVA, Via Campi Flegrei 34, Pozzuoli 80078 (Italy); Rogalla, Detlef [Institut fuer Experimentalphysik III, Ruhr-Universitaet Bochum, Bochum D-44780 (Germany); Sabbarese, Carlo [Dipartimento di Scienze Ambientali, II Universita di Napoli, Via Vivaldi 43, Caserta 81100 (Italy); CIRCE, INNOVA, Via Campi Flegrei 34, Pozzuoli 80078 (Italy); Borriello, Gianluca; Casa, Giovanni; Palmieri, Antonio [Dipartimento di Scienze Ambientali, II Universita di Napoli, Via Vivaldi 43, Caserta 81100 (Italy)

    2008-05-15

    The CIRCE AMS system started operation in March 2005. The measurement of isotopic ratios {sup 14}C/{sup 12}C in samples of archaeological and environmental interest has rapidly attained high precision and accuracy levels in routine operation. The results of the intercomparison campaign in the framework of the VIRI program, as well as the outcome of a statistical analysis of the about 200 control measurements performed with standard samples, have shown the capability of the whole system for high precision measurements ({delta}R/R < 0.3%), allowing systematic investigations in both archaeological and environmental sciences. {sup 26}Al AMS has been implemented for the measurement of the astrophysically relevant {sup 25}Mg(p,{gamma}){sup 26}Al reaction cross section, while a beam line is under construction for the measurement of actinides isotopic ratios.

  16. Research News -- Meson scattering at high precision

    CERN Document Server

    Ananthanarayan, B

    2007-01-01

    A fascinating new generation of experiments has determined certain meson scattering parameters at high precision. A confluence of highly sophisticated theory as well as new experimental ideas have led to this state of affairs, which sheds important light on the properties of the strong interactions. A brief review of the experiments and the theory is presented.

  17. High precision, rapid laser hole drilling

    Science.gov (United States)

    Chang, Jim J.; Friedman, Herbert W.; Comaskey, Brian J.

    2013-04-02

    A laser system produces a first laser beam for rapidly removing the bulk of material in an area to form a ragged hole. The laser system produces a second laser beam for accurately cleaning up the ragged hole so that the final hole has dimensions of high precision.

  18. High-Precision Photometry with the RCT

    Science.gov (United States)

    Everett, M.; Howell, S.; Davis, D.; McGruder, C. H., III; Gelderman, R.; Guinan, E.; Mattox, J. R.; Walter, D. K.

    2003-05-01

    We plan to conduct a high-precision photometric search for transitting extra-solar planets using the refurbished 1.3 m (50 inch) Robotically-Controlled Telescope (RCT) at Kitt Peak. The photometric capabilities and extra-solar planet search strategy for the RCT are discussed. Refurbishment of the RCT has been made possible by NASA grant NAG58762.

  19. Preparatory studies for a high-precision Penning-trap measurement of the {sup 163}Ho electron capture Q-value

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, F. [Johannes Gutenberg-Universitaet, Institut fuer Kernchemie, Mainz (Germany); Johannes Gutenberg-Universitaet, Institut fuer Physik, Mainz (Germany); Beyer, T.; Blaum, K.; Eibach, M.; Eliseev, S.; Nagy, Sz. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Block, M. [Johannes Gutenberg-Universitaet, Institut fuer Kernchemie, Mainz (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Helmholtz-Institut Mainz, Mainz (Germany); Chenmarev, S.; Novikov, Yu.N. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Saint Petersburg State University, Physical Faculty, Saint Petersburg (Russian Federation); Dorrer, H. [Johannes Gutenberg-Universitaet, Institut fuer Kernchemie, Mainz (Germany); Paul Scherrer Institute, Villigen (Switzerland); Universitaet Bern, Bern (Switzerland); Duellmann, C.E. [Johannes Gutenberg-Universitaet, Institut fuer Kernchemie, Mainz (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Helmholtz-Institut Mainz, Mainz (Germany); Johannes Gutenberg-Universitaet, PRISMA Cluster of Excellence, Mainz (Germany); Eberhardt, K. [Johannes Gutenberg-Universitaet, Institut fuer Kernchemie, Mainz (Germany); Helmholtz-Institut Mainz, Mainz (Germany); Grund, J. [Johannes Gutenberg-Universitaet, Institut fuer Kernchemie, Mainz (Germany); Johannes Gutenberg-Universitaet, PRISMA Cluster of Excellence, Mainz (Germany); Koester, U. [Institut Laue-Langevin, Grenoble (France); Renisch, D. [Johannes Gutenberg-Universitaet, Institut fuer Kernchemie, Mainz (Germany); Tuerler, A. [Paul Scherrer Institute, Villigen (Switzerland); Universitaet Bern, Bern (Switzerland); Wendt, K. [Johannes Gutenberg-Universitaet, Institut fuer Physik, Mainz (Germany); Johannes Gutenberg-Universitaet, PRISMA Cluster of Excellence, Mainz (Germany)

    2015-07-15

    The ECHo Collaboration (Electron Capture {sup 163}Ho) aims to investigate the calorimetric spectrum following the electron capture decay of {sup 163}Ho to determine the mass of the electron neutrino. The size of the neutrino mass is reflected in the endpoint region of the spectrum, i.e., the last few eV below the transition energy. To check for systematic uncertainties, an independent determination of this transition energy, the Q-value, is mandatory. Using the TRIGA-TRAP setup, we demonstrate the feasibility of performing this measurement by Penning-trap mass spectrometry. With the currently available, purified {sup 163}Ho sample and an improved laser ablation mini-RFQ ion source, we were able to perform direct mass measurements of {sup 163}Ho and {sup 163}Dy with a sample size of less than 10{sup 17} atoms. The measurements were carried out by determining the ratio of the cyclotron frequencies of the two isotopes to those of carbon cluster ions using the time-of-flight ion cyclotron resonance method. The obtained mass excess values are ME({sup 163}Ho)= -66379.3(9) keV and ME({sup 163}Dy)= -66381.7(8) keV. In addition, the Q-value was measured for the first time by Penning-trap mass spectrometry to be Q = 2.5(7) keV. (orig.)

  20. Portable high precision pressure transducer system

    Science.gov (United States)

    Piper, T. C.; Morgan, J. P.; Marchant, N. J.; Bolton, S. M.

    A high precision pressure transducer system for checking the reliability of a second pressure transducer system used to monitor the level of a fluid confined in a holding tank is presented. Since the response of the pressure transducer is temperature sensitive, it is continually housed in a battery powered oven which is configured to provide a temperature stable environment at specified temperature for an extended period of time. Further, a high precision temperature stabilized oscillator and counter are coupled to a single board computer to accurately determine the pressure transducer oscillation frequency and convert it to an applied pressure. All of the components are powered by the batteries which during periods of availability of line power are charged by an on-board battery charger. The pressure readings outputs are transmitted to a line printer and a vacuum fluorescent display.

  1. High-Precision Computation and Mathematical Physics

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, David H.; Borwein, Jonathan M.

    2008-11-03

    At the present time, IEEE 64-bit floating-point arithmetic is sufficiently accurate for most scientific applications. However, for a rapidly growing body of important scientific computing applications, a higher level of numeric precision is required. Such calculations are facilitated by high-precision software packages that include high-level language translation modules to minimize the conversion effort. This paper presents a survey of recent applications of these techniques and provides some analysis of their numerical requirements. These applications include supernova simulations, climate modeling, planetary orbit calculations, Coulomb n-body atomic systems, scattering amplitudes of quarks, gluons and bosons, nonlinear oscillator theory, Ising theory, quantum field theory and experimental mathematics. We conclude that high-precision arithmetic facilities are now an indispensable component of a modern large-scale scientific computing environment.

  2. 高精度的测距系统中的测相技术研究%Study on the phase difference measurement technology in high precision distance measurement system

    Institute of Scientific and Technical Information of China (English)

    屈八一; 周渭; 李珊珊; 王江安

    2012-01-01

    The high precision phase difference measurement technology is one of the key technologies in the system of measuring the distance between satellite to satellite or satellite to the ground with high precision quality. This paper studies the phase difference measurement technology based on a double frequency subtraction phase difference measurement technology and its applications in the above distance measurement system. Experimental results show that phase difference measurement technology has a resolution better than 10-6 and the distance deviation caused by the noise floor of the system itself is less than 77μm.%高精度的测相技术是星星间或星地间的测距系统中的关键技术之一.研究了基于双差频测相技术的高精度测相技术及其在上述高精度的测距系统中的应用.实验结果表明双差频测相技术具有10-6以上的测相分辨率及由系统本底噪声引起的测距误差小于7μm.

  3. High-Precision Spectroscopy with Counter-Propagating Femtosecond Pulses

    CERN Document Server

    Barmes, Itan; Eikema, Kjeld S E

    2013-01-01

    An experimental realization of high-precision direct frequency comb spectroscopy using counter-propagating femtosecond pulses on two-photon atomic transitions is presented. Doppler broadened background signal, hampering precision spectroscopy with ultrashort pulses, is effectively eliminated with a simple pulse shaping method. As a result, all four 5S-7S two-photon transitions in a rubidium vapor are determined with both statistical and systematic uncertainties below 10$^{-11}$, which is an order of magnitude better than previous experiments on these transitions.

  4. TerraSAR-X Data for High-Precision Land Subsidence Monitoring: A Case Study in the Historical Centre of Hanoi, Vietnam

    Directory of Open Access Journals (Sweden)

    Tuan S. Le

    2016-04-01

    Full Text Available In this study, subsidence patterns in the Historical Centre of Hanoi, Vietnam are mapped using the Interferometric Synthetic Aperture Radar (InSAR technique, with particular emphasis on the stability of ancient monuments, historical buildings and archaeological sectors. Due to the small and scattered characteristics of these structures, not only is a comprehensive coverage of radar targets needed, but also the details of a single building or monument. We took advantage of the high-resolution TerraSAR-X imagery with the aid of oversampling implementation on the Small Baseline (SB InSAR approach to reveal the subsidence patterns. A total of 6.29 million radar targets were obtained, maintaining the average density of 217,012 points/km2. Our results suggest that image oversampling not only increased the number of measurement points 4.4 times more than the standard processing chain, but also removed some of the noisiest points. The observed subsidence patterns are mostly related to adjacent groundwater extraction and construction activities, with maximum subsiding rate reaching −18.1 mm/year for the study period April 2012 to November 2013. Generally, heritage assets and monuments in the Citadel, the Old Quarter and French Quarter remain in a steady state, whereas those located along the Red River and in southern Hanoi are subject to subsidence.

  5. High precision detector robot arm system

    Science.gov (United States)

    Shu, Deming; Chu, Yong

    2017-01-31

    A method and high precision robot arm system are provided, for example, for X-ray nanodiffraction with an X-ray nanoprobe. The robot arm system includes duo-vertical-stages and a kinematic linkage system. A two-dimensional (2D) vertical plane ultra-precision robot arm supporting an X-ray detector provides positioning and manipulating of the X-ray detector. A vertical support for the 2D vertical plane robot arm includes spaced apart rails respectively engaging a first bearing structure and a second bearing structure carried by the 2D vertical plane robot arm.

  6. Recent high precision surveys at PEP

    Energy Technology Data Exchange (ETDEWEB)

    Sah, R.C.

    1980-12-01

    The task of surveying and aligning the components of PEP has provided an opportunity to develop new instruments and techniques for the purpose of high precision surveys. The new instruments are quick and easy to use, and they automatically encode survey data and read them into the memory of an on-line computer. When measurements of several beam elements have been taken, the on-line computer analyzes the measured data, compares them with desired parameters, and calculates the required adjustments to beam element support stands.

  7. High precision detector robot arm system

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Deming; Chu, Yong

    2017-01-31

    A method and high precision robot arm system are provided, for example, for X-ray nanodiffraction with an X-ray nanoprobe. The robot arm system includes duo-vertical-stages and a kinematic linkage system. A two-dimensional (2D) vertical plane ultra-precision robot arm supporting an X-ray detector provides positioning and manipulating of the X-ray detector. A vertical support for the 2D vertical plane robot arm includes spaced apart rails respectively engaging a first bearing structure and a second bearing structure carried by the 2D vertical plane robot arm.

  8. A simple and feasible process for using multi-stage high-precision DTMs, field surveys and rainfall data to study debris flow occurrence factors of Shenmu area, Taiwan

    Directory of Open Access Journals (Sweden)

    W.-C. Lo

    2012-11-01

    Full Text Available The occurrence of typhoon Herb in 1996 caused massive landslides in the Shenmu area of Taiwan. Many people died and stream and river beds were covered by meters of debris. Debris flows almost always take place in the Shenmu area during the flood season, especially in the catchment areas around Tsushui river and Aiyuzih river. Anthropogenic and natural factors that cause debris flow occurrences are complex and numerous. The precise conditions of initiation are difficult to be identified, but three factors are generally considered to be the most important ones, i.e. rainfall characteristics, geologic conditions and topography. This study proposes a simple and feasible process that combines remote sensing technology and multi-stage high-precision DTMs from aerial orthoimages and airborne LiDAR with field surveys to establish a connection between three major occurrence factors that trigger debris flows in the Shenmu area.

  9. Mechanical Analysis of high precision manipulator

    Directory of Open Access Journals (Sweden)

    O.J. Elle

    1995-10-01

    Full Text Available It is of great importance that high precision manipulators are well designed from a mechanical point of view. A thorough analysis of all mechanical aspects concerning an accurate manipulator will make a good basis for further design. This paper presents a new approach to mechanical analysis of high-precision manipulators. A typical six axis anthropomorphic manipulator configuration is chosen as a model for the analysis. The paper is divided into two main parts; static deformation analysis and dynamic analysis. The static deformation analysis consists of three sub-parts; link deformation, joint deformation and total mechanical deformation. A simple fixed beam deformation model is used to simulate every link. Both specific gravity and a load attached at the end of the beam is considered. By varying material, outer dimensions and wall thickness it is possible to determine optimal values. Looking at the whole structure with an attacking force at the end, it is possible to select appropriate motor/transmission combinations. Each combination represents compliance and combined with the arm compliance the total deformation can be found. The result shows that deformation due to compliance in the joints represents 97

  10. High Precision Measurements Using High Frequency Signals

    CERN Document Server

    Jin, Aohan; Sakurai, Atsunori; Liu, Liang; Edman, Fredrik; Öwall, Viktor; Pullerits, Tonu; Karki, Khadga J

    2014-01-01

    Generalized lock-in amplifiers use digital cavities with Q-factors as high as 5X10^8. In this letter, we show that generalized lock-in amplifiers can be used to analyze microwave (giga-hertz) signals with a precision of few tens of hertz. We propose that the physical changes in the medium of propagation can be measured precisely by the ultra-high precision measurement of the signal. We provide evidence to our proposition by verifying the Newton's law of cooling by measuring the effect of change in temperature on the phase and amplitude of the signals propagating through two calibrated cables. The technique could be used to precisely measure different physical properties of the propagation medium, for example length, resistance, etc. Real time implementation of the technique can open up new methodologies of in-situ virtual metrology in material design.

  11. High-precision ground-based photometry of exoplanets

    Directory of Open Access Journals (Sweden)

    de Mooij Ernst J.W.

    2013-04-01

    Full Text Available High-precision photometry of transiting exoplanet systems has contributed significantly to our understanding of the properties of their atmospheres. The best targets are the bright exoplanet systems, for which the high number of photons allow very high signal-to-noise ratios. Most of the current instruments are not optimised for these high-precision measurements, either they have a large read-out overhead to reduce the readnoise and/or their field-of-view is limited, preventing simultaneous observations of both the target and a reference star. Recently we have proposed a new wide-field imager for the Observatoir de Mont-Megantic optimised for these bright systems (PI: Jayawardhana. The instruments has a dual beam design and a field-of-view of 17' by 17'. The cameras have a read-out time of 2 seconds, significantly reducing read-out overheads. Over the past years we have obtained significant experience with how to reach the high precision required for the characterisation of exoplanet atmospheres. Based on our experience we provide the following advice: Get the best calibrations possible. In the case of bad weather, characterise the instrument (e.g. non-linearity, dome flats, bias level, this is vital for better understanding of the science data. Observe the target for as long as possible, the out-of-transit baseline is as important as the transit/eclipse itself. A short baseline can lead to improperly corrected systematic and mis-estimation of the red-noise. Keep everything (e.g. position on detector, exposure time as stable as possible. Take care that the defocus is not too strong. For a large defocus, the contribution of the total flux from the sky-background in the aperture could well exceed that of the target, resulting in very strict requirements on the precision at which the background is measured.

  12. Design of high-precision ranging system for laser fuze

    Science.gov (United States)

    Chen, Shanshan; Zhang, He; Xu, Xiaobin

    2016-10-01

    According to the problem of the high-precision ranging in the circumferential scanning probe laser proximity fuze, a new type of pulsed laser ranging system has been designed. The laser transmitting module, laser receiving module and ranging processing module have been designed respectively. The factors affecting the ranging accuracy are discussed. And the method of improving the ranging accuracy is studied. The high-precision ranging system adopts the general high performance microprocessor C8051FXXX as the core. And the time interval measurement chip TDC-GP21 was used to implement the system. A PCB circuit board was processed to carry on the experiment. The results of the experiment prove that a centimeter level accuracy ranging system has been achieved. The works can offer reference for ranging system design of the circumferential scanning probe laser proximity fuze.

  13. Design and control of a high precision drive mechanism

    Science.gov (United States)

    Pan, Bo; He, Yongqiang; Wang, Haowei; Zhang, Shuyang; Zhang, Donghua; Wei, Xiaorong; Jiang, Zhihong

    2017-01-01

    This paper summarizes the development of a high precision drive mechanism (HPDM) for space application, such as the directional antenna, the laser communication device, the mobile camera and other pointing mechanisms. In view of the great practical significance of high precision drive system, control technology for permanent magnet synchronous motor (PMSM) servo system is also studied and a PMSM servo controller is designed in this paper. And the software alignment was applied to the controller to eliminate the steady error of the optical encoder, which helps to realize the 1 arcsec (1σ) control precision. To assess its capabilities, the qualification environment testing including the thermal vacuum cycling testing, and the sinusoidal and random vibration were carried out. The testing results show that the performance of the HPDM is almost the same between the former and the end of each testing.

  14. High precision innovative micropump for artificial pancreas

    Science.gov (United States)

    Chappel, E.; Mefti, S.; Lettieri, G.-L.; Proennecke, S.; Conan, C.

    2014-03-01

    The concept of artificial pancreas, which comprises an insulin pump, a continuous glucose meter and a control algorithm, is a major step forward in managing patient with type 1 diabetes mellitus. The stability of the control algorithm is based on short-term precision micropump to deliver rapid-acting insulin and to specific integrated sensors able to monitor any failure leading to a loss of accuracy. Debiotech's MEMS micropump, based on the membrane pump principle, is made of a stack of 3 silicon wafers. The pumping chamber comprises a pillar check-valve at the inlet, a pumping membrane which is actuated against stop limiters by a piezo cantilever, an anti-free-flow outlet valve and a pressure sensor. The micropump inlet is tightly connected to the insulin reservoir while the outlet is in direct communication with the patient skin via a cannula. To meet the requirement of a pump dedicated to closed-loop application for diabetes care, in addition to the well-controlled displacement of the pumping membrane, the high precision of the micropump is based on specific actuation profiles that balance effect of pump elasticity in low-consumption push-pull mode.

  15. Magnetic Shielding Method and Experiment Study of Inertial Measurement Unit Based on High Precision Fiber-optic Gyroscope%高精度光纤IMU的磁屏蔽方法及实验研究

    Institute of Scientific and Technical Information of China (English)

    李金涛; 房建成

    2011-01-01

    惯性测量单元(IMU)是位置姿态系统(POS)的核心部分,IMU的精度很大程度上决定着POS精度.由于高精度光纤陀螺(FOG)的光纤线圈对磁场敏感,基于高精度FOG的IMU精度会受磁场影响而降低.本文研究了FOG磁敏感性机理,通过实验得出高精度光纤IMU对磁场敏感的结论.采用电磁场有限元分析软件Ansoft Maxwell研究了磁屏蔽体采用不同材料、不同厚度时的磁屏蔽效能(SE),并进行了IMU磁屏蔽结构设计.通过亥姆霍兹线圈测试得到的磁屏蔽体实际屏蔽效能最高为48.20 dB,与有限元分析结果基本一致.转台环境测试表明:屏蔽体使FOG漂移减小到9%以上;亥姆霍兹线圈测试表明:通过磁屏蔽使FOG零偏磁敏感度衰减2~21 dB,漂移磁敏感度衰减9~23 dB,对提高光纤IMU测试和应用精度以及机载环境适应性有重要意义.%The inertial measurement unit (IMU) is the core of a position and orientation system (POS), whose accuracy has a crucial impact on POS accuracy. But the IMU accuracy based on high precision fiber-optic gyroscope (FOG) is degraded because of the sensitivity of the FOG fiber coil to the magnetic field. This paper studied the magnetic sensitivity mechanism of the FOG. And through experimental study reached the conclusion that the IMU based on a high precision FOG is also sensitive to the magnetic field. An IMU shielding is designed, and its shielding effectiveness (SE) is analyzed by electromagnetic field finite element analysis software Ansoft Maxwell for different materials with different thicknesses. The best SE of 48.20 Db is achieved with a Helmholtz coil test, which is consistent with the results of the finite element analysis. The turn table test shows that a reduction of over 9% of the FOG drift is achieved with the enclosure. The Helmholtz coil test with magnetic shielding demonstrates that the bias and drift magnetic sensitivity of the FOG are decreased by 2-21 Db and 9-23 Db

  16. A High Precision, Optical Polarimeter to Measure Inclinations of High Mass X-Ray Binaries

    CERN Document Server

    Wiktorowicz, Sloane J

    2008-01-01

    We present commissioning data for the POLISH instrument obtained on the Hale 5-m telescope. The goal of this high precision polarimeter is to constrain orbital inclination of high mass X-ray binaries and to therefore obtain independent mass estimates for their black hole companions. We have obtained photon shot noise limited precision on standard stars, and we have measured the polarization of bright stars at the part per million level on a nightly basis. Systematic effects have been reduced to less than 1% of the measured polarization for polarized sources and to the part per million level for weakly polarized sources. The high sensitivity of this instrument to asymmetry suggests that valuable contributions will be made in many other fields, including studies of extrasolar planets, debris disks, and stellar astrophysics.

  17. High-Precision Computation: Mathematical Physics and Dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, D. H.; Barrio, R.; Borwein, J. M.

    2010-04-01

    At the present time, IEEE 64-bit oating-point arithmetic is suficiently accurate for most scientic applications. However, for a rapidly growing body of important scientic computing applications, a higher level of numeric precision is required. Such calculations are facilitated by high-precision software packages that include high-level language translation modules to minimize the conversion e ort. This pa- per presents a survey of recent applications of these techniques and provides someanalysis of their numerical requirements. These applications include supernova simulations, climate modeling, planetary orbit calculations, Coulomb n-body atomic systems, studies of the one structure constant, scattering amplitudes of quarks, glu- ons and bosons, nonlinear oscillator theory, experimental mathematics, evaluation of orthogonal polynomials, numerical integration of ODEs, computation of periodic orbits, studies of the splitting of separatrices, detection of strange nonchaotic at- tractors, Ising theory, quantum held theory, and discrete dynamical systems. We conclude that high-precision arithmetic facilities are now an indispensable compo- nent of a modern large-scale scientic computing environment.

  18. MultiView High Precision VLBI Astrometry at Low Frequencies

    Science.gov (United States)

    Rioja, María J.; Dodson, Richard; Orosz, Gabor; Imai, Hiroshi; Frey, Sandor

    2017-03-01

    The arrival of the Square Kilometer Array (SKA) will revitalize all aspects of Very Long Baseline Interferometry (VLBI) astronomy at lower frequencies. In the last decade, there have been huge strides toward routinely achieving high precision VLBI astrometry at frequencies dominated by tropospheric contributions, most notably at 22 GHz, using advanced phase-referencing techniques. Nevertheless, to increase the capability for high precision astrometric measurements at low radio frequencies (phase-referencing calibrator. The MultiView technique holds the key to compensating for atmospheric spatial-structure errors, by using observations of multiple calibrators and two-dimensional interpolation in the visibility domain. In this paper we present the first demonstration of the power of MultiView using three calibrators, several degrees from the target, along with a comparative study of the astrometric accuracy between MultiView and phase-referencing techniques. MultiView calibration provides an order of magnitude improvement in astrometry with respect to conventional phase referencing, achieving ∼100 μas astrometry errors in a single epoch of observations, effectively reaching the thermal noise limit. MultiView will achieve its full potential with the enhanced sensitivity and multibeam capabilities of SKA and the pathfinders, which will enable simultaneous observations of the target and calibrators. Our demonstration indicates that the 10 μas goal of astrometry at ∼1.6 GHz using VLBI with SKA is feasible using the MultiView technique.

  19. High-Precision Direct Mass Determination of Unstable Isotopes

    CERN Multimedia

    2002-01-01

    The extension of systematic high-precision measurements of the nuclear mass to nuclei far from the valley of $\\beta$ stability is of great interest in nuclear physics and astrophysics. The mass, or binding energy, is a fundamental gross property and a key input parameter for nuclear matter calculations. It is also a sensitive probe for collective and single-particle effects in nuclear structure. \\\\ \\\\ For such purposes, nuclear masses need to be known to an accuracy of about 10$^{-7}$ (i.e. $\\Delta$M~$\\leq$~10~keV for A~=~100). To resolve a particular mass from its nuclear isomers and isobars, resolving power of 10$^6$ are often required. To achieve this, the ions delivered by the on-line mass separator ISOLDE are confined in a Penning quadrupole trap. This trap is placed in the very homogeneous and stable magnetic field of a superconducting magnet. Here, the cyclotron frequency and hence the mass are determined. \\\\ \\\\ The first measurements using this new technique have been completed for a long chain of Cs ...

  20. A high-precision polarimeter for small telescopes

    Science.gov (United States)

    Bailey, Jeremy; Cotton, Daniel V.; Kedziora-Chudczer, Lucyna

    2017-02-01

    We describe Mini-HIPPI (Miniature HIgh Precision Polarimetric Instrument), a stellar polarimeter weighing just 650 gm but capable of measuring linear polarization to ˜10-5. Mini-HIPPI is based on the use of a Ferroelectric Liquid Crystal modulator. It can easily be mounted on a small telescope and allows us to study the polarization of bright stars at levels of precision which are hitherto largely unexplored. We present results obtained with Mini-HIPPI on a 35-cm telescope. Measurements of polarized standard stars are in good agreement with predicted values. Measurements of a number of bright stars agree well with those from other high-sensitivity polarimeters. Observations of the binary system Spica show polarization variability around the orbital cycle.

  1. Preparation of cold molecules for high-precision measurements

    Science.gov (United States)

    Wall, T. E.

    2016-12-01

    Molecules can be used to test fundamental physics. Such tests often require cold molecules for detailed spectroscopic analysis. Cooling internal degrees of freedom provides a high level of state-selectivity, with large populations in the molecular states of interest. Cold translational motion allows slow, bright beams to be created, allowing long interaction times. In this tutorial article we describe the common techniques for producing cold molecules for high-precision spectroscopy experiments. For each technique we give examples of its application in experiments that use molecular structure to probe fundamental physics, choosing one experiment in particular as a case study. We then discuss a number of new techniques, some currently under development, others proposed, that promise high flux sources of cold molecules applicable to precise spectroscopic tests of fundamental physics.

  2. Monolithic interferometer for high precision radial velocity measurements

    Science.gov (United States)

    Wan, Xiaoke; Ge, Jian; Wang, Ji; Lee, Brian

    2009-08-01

    In high precision radial velocity (RV) measurements for extrasolar planets searching and studies, a stable wide field Michelson interferometer is very critical in Exoplanet Tracker (ET) instruments. Adopting a new design, monolithic interferometers are homogenous and continuous in thermal expansion, and field compensation and thermal compensation are both satisfied. Interferometer design and fabrication are decrypted in details. In performance evaluations, field angle is typically 22° and thermal sensitivity is typically -1.7 x 10-6/°C, which corresponds to ~500 m/s /°C in RV scale. In interferometer stability monitoring using a wavelength stabilized laser source, phase shift data was continuously recorded for nearly seven days. Appling a frequent calibration every 30 minutes as in typical star observations, the interferometer instability contributes less than 1.4 m/s in RV error, in a conservative estimation.

  3. High-Precision Spectroscopy of Pulsating Stars

    CERN Document Server

    Aerts, C; Desmet, M; Carrier, F; Zima, W; Briquet, M; De Ridder, J

    2007-01-01

    We review methodologies currently available to interprete time series of high-resolution high-S/N spectroscopic data of pulsating stars in terms of the kind of (non-radial) modes that are excited. We illustrate the drastic improvement of the detection treshold of line-profile variability thanks to the advancement of the instrumentation over the past two decades. This has led to the opportunity to interprete line-profile variations with amplitudes of order m/s, which is a factor 1000 lower than the earliest line-profile time series studies allowed for.

  4. High precision mass measurements for wine metabolomics

    Science.gov (United States)

    Roullier-Gall, Chloé; Witting, Michael; Gougeon, Régis; Schmitt-Kopplin, Philippe

    2014-11-01

    An overview of the critical steps for the non-targeted Ultra-High Performance Liquid Chromatography coupled with Quadrupole Time-of-Flight Mass Spectrometry (UPLC-Q-ToF-MS) analysis of wine chemistry is given, ranging from the study design, data preprocessing and statistical analyses, to markers identification. UPLC-Q-ToF-MS data was enhanced by the alignment of exact mass data from FTICR-MS, and marker peaks were identified using UPLC-Q-ToF-MS². In combination with multivariate statistical tools and the annotation of peaks with metabolites from relevant databases, this analytical process provides a fine description of the chemical complexity of wines, as exemplified in the case of red (Pinot noir) and white (Chardonnay) wines from various geographic origins in Burgundy.

  5. High precision flux measurements with ENUBET

    Science.gov (United States)

    Pozzato, M.; ENUBET collaboration

    2017-09-01

    The challenges of precision neutrino physics (i.e the study of CP violation) require measurements of absolute ν cross sections at the GeV scale with exquisite (O(1)%) precision. Such precision is presently limited to about 10% by the uncertainties on neutrino flux at the source. A reduction of this uncertainty by one order of magnitude can be achieved monitoring the positron production in the decay tunnel originating from the Ke3 decays of charged kaons in a sign and momentum selected narrow band beam. This novel technique enables the measurement of the most relevant cross-sections for CP violation (νe and {\\displaystyle \\bar{ν }}e) with a precision of 1% and requires a special instrumented beam-line. Such non-conventional beam-line will be developed in the framework of the ENUBET Horizon-2020 Consolidator Grant (PI A. Longhin), recently approved by the European Research Council (grant agreement N° 681647). In this poster, we will present the Project and the early experimental results on ultra-compact calorimeters that can embedded in the instrumented decay tunnel.

  6. Prospects for High-Precision Pulsar Timing

    CERN Document Server

    Liu, K; Kramer, M; Stappers, B W; van Straten, W; Cordes, J M

    2011-01-01

    Timing pulses of pulsars has proved to be a most powerful technique useful to a host of research areas in astronomy and physics. Importantly, the precision of this timing is not only affected by radiometer noise, but also by intrinsic pulse shape changes, interstellar medium (ISM) evolution, instrumental distortions, etc. In this paper we review the known causes of pulse shape variations and assess their effect on the precision and accuracy of a single measurement of pulse arrival time with current instrumentation. Throughout this analysis we use the brightest and most precisely timed millisecond pulsar (MSP), PSR J0437-4715, as a case study, and develop a set of diagnostic tools to evaluate profile stability in timing observations. We conclude that most causes of distortion can be either corrected by state-of-the-art techniques or taken into account in the estimation of time-of-arrival (TOA) uncertainties. The advent of a new generation of radio telescopes (e.g. the Square Kilometre Array, SKA), and their in...

  7. Design of High Precision Temperature Measurement System based on Labview

    Directory of Open Access Journals (Sweden)

    Weimin Zhu

    2015-06-01

    Full Text Available Using the LabVIEW software platform, a high precision temperature measuring device is designed based on the principle of the thermocouple. The system uses the STM32 MCU as the main control chip, using AD7076 analog digital converter. The converter has 8 channel, synchronous sampling, and bipolar input. Improving the precision of temperature measurement by cold end compensation, fitting and other measures. The test results show that, the device temperature measurement precision can reach ±0.1 °C, has the advantages of small size, high precision, and reliable performance, this high precision temperature measurement can be widely used in industrial production.

  8. [High Precision Identification of Igneous Rock Lithology by Laser Induced Breakdown Spectroscopy].

    Science.gov (United States)

    Wang, Chao; Zhang, Wei-gang; Yan, Zhi-quan

    2015-09-01

    In the field of petroleum exploration, lithology identification of finely cuttings sample, especially high precision identification of igneous rock with similar property, has become one of the geological problems. In order to solve this problem, a new method is proposed based on element analysis of Laser-Induced Breakdown Spectroscopy (LIBS) and Total Alkali versus Silica (TAS) diagram. Using independent LIBS system, factors influencing spectral signal, such as pulse energy, acquisition time delay, spectrum acquisition method and pre-ablation are researched through contrast experiments systematically. The best analysis conditions of igneous rock are determined: pulse energy is 50 mJ, acquisition time delay is 2 μs, the analysis result is integral average of 20 different points of sample's surface, and pre-ablation has been proved not suitable for igneous rock sample by experiment. The repeatability of spectral data is improved effectively. Characteristic lines of 7 elements (Na, Mg, Al, Si, K, Ca, Fe) commonly used for lithology identification of igneous rock are determined, and igneous rock samples of different lithology are analyzed and compared. Calibration curves of Na, K, Si are generated by using national standard series of rock samples, and all the linearly dependent coefficients are greater than 0.9. The accuracy of quantitative analysis is investigated by national standard samples. Element content of igneous rock is analyzed quantitatively by calibration curve, and its lithology is identified accurately by the method of TAS diagram, whose accuracy rate is 90.7%. The study indicates that LIBS can effectively achieve the high precision identification of the lithology of igneous rock.

  9. High Precision Measurements of $\\theta_{\\odot}$ in Solar and Reactor Neutrino Experiments

    CERN Document Server

    Bandyopadhyay, A; Goswami, S; Petcov, S T; Bandyopadhyay, Abhijit; Choubey, Sandhya; Goswami, Srubabati

    2004-01-01

    We discuss the possibilities of high precision measurement of the solar neutrino mixing angle $\\theta_\\odot \\equiv \\theta_{12}$ in solar and reactor neutrino experiments. The improvements in the determination of $\\sin^2\\theta_{12}$, which can be achieved with the expected increase of statistics and reduction of systematic errors in the currently operating solar and KamLAND experiments, are summarised. The potential of LowNu $\

  10. Repeated High-Precision Gravity and GPS Measurement Techniques

    Science.gov (United States)

    Gettings, P.; Harris, R. N.; Allis, R.; Chapman, D. S.

    2003-12-01

    Repeated high-precision gravity and GPS measurements are becoming a common tool for tracking changes in subsurface reservoirs. Despite this, there is little literature which discusses measurement techniques and the expected errors. Our research has focused on improving measurement techniques to be applied to ground water and geothermal steam reservoirs, including quantifying the minimum error levels with modern equipment. We applied these methods in two studies: ground water monitoring of the southern Salt Lake valley, Utah, USA, and steam monitoring of The Geysers geothermal field, California, USA. Gravity measurements using modern relative high-precision meters, such as Scintrex CG-3Ms or L&R E series, can now be routinely made to an accuracy of 5 μ Gal. Such accuracy requires the use of time series analysis at each station, and non-linear instrument drift functions. Modern computerized meters are capable of internally storing a time series of measurements for each station; older meters can often be fitted to log such data to a field computer. This time series, typically of 10-15 minute duration in our work, can then be analyzed in several ways to produce stable estimates of the gravity reading. In particular, our research has emphasized using a weighted arithmetic average (for long occupations), or a Thiele extrapolation scheme (for shorter station occupations). Instrument drift is removed through a superposition of a linear long-term drift function, and an empirical staircase function formed from differences between repeated station occupations. To achieve high-accuracy GPS measurements while maximizing the number of field stations in a survey, rapid-static measurements are necessary. We have tested the effect of occupation time and processing schemes on the absolute accuracy of the resulting GPS position. Using a post-processing differential method with a fixed (but not necessarily continuous) base station within 15 km, positioning error of <4 cm vertical is

  11. High precision spectroscopy and imaging in THz frequency range

    Science.gov (United States)

    Vaks, Vladimir L.

    2014-03-01

    Application of microwave methods for development of the THz frequency range has resulted in elaboration of high precision THz spectrometers based on nonstationary effects. The spectrometers characteristics (spectral resolution and sensitivity) meet the requirements for high precision analysis. The gas analyzers, based on the high precision spectrometers, have been successfully applied for analytical investigations of gas impurities in high pure substances. These investigations can be carried out both in absorption cell and in reactor. The devices can be used for ecological monitoring, detecting the components of chemical weapons and explosive in the atmosphere. The great field of THz investigations is the medicine application. Using the THz spectrometers developed one can detect markers for some diseases in exhaled air.

  12. Bounding the Probability of Error for High Precision Recognition

    CERN Document Server

    Kae, Andrew; Learned-Miller, Erik

    2009-01-01

    We consider models for which it is important, early in processing, to estimate some variables with high precision, but perhaps at relatively low rates of recall. If some variables can be identified with near certainty, then they can be conditioned upon, allowing further inference to be done efficiently. Specifically, we consider optical character recognition (OCR) systems that can be bootstrapped by identifying a subset of correctly translated document words with very high precision. This "clean set" is subsequently used as document-specific training data. While many current OCR systems produce measures of confidence for the identity of each letter or word, thresholding these confidence values, even at very high values, still produces some errors. We introduce a novel technique for identifying a set of correct words with very high precision. Rather than estimating posterior probabilities, we bound the probability that any given word is incorrect under very general assumptions, using an approximate worst case ...

  13. High precision u/th dating of first Polynesian settlement.

    Directory of Open Access Journals (Sweden)

    David Burley

    Full Text Available Previous studies document Nukuleka in the Kingdom of Tonga as a founder colony for first settlement of Polynesia by Lapita peoples. A limited number of radiocarbon dates are one line of evidence supporting this claim, but they cannot precisely establish when this event occurred, nor can they afford a detailed chronology for sequent occupation. High precision U/Th dates of Acropora coral files (abraders from Nukuleka give unprecedented resolution, identifying the founder event by 2838±8 BP and documenting site development over the ensuing 250 years. The potential for dating error due to post depositional diagenetic alteration of ancient corals at Nukuleka also is addressed through sample preparation protocols and paired dates on spatially separated samples for individual specimens. Acropora coral files are widely distributed in Lapita sites across Oceania. U/Th dating of these artifacts provides unparalleled opportunities for greater precision and insight into the speed and timing of this final chapter in human settlement of the globe.

  14. Preparing polished crystal slices with high precision orientation

    DEFF Research Database (Denmark)

    Mathiesen, S. Ipsen; Gerward, Leif; Pedersen, O.

    1974-01-01

    A polishing procedure is described which utilizes a high precision Laue technique for crystal orientation. Crystal slices with their final polished surfaces parallel to a crystallographic plane within 0.02° can be prepared. ©1974 The American Institute of Physics......A polishing procedure is described which utilizes a high precision Laue technique for crystal orientation. Crystal slices with their final polished surfaces parallel to a crystallographic plane within 0.02° can be prepared. ©1974 The American Institute of Physics...

  15. Intellective high-precision macromolecule resistance temperature/humidity instrument

    Science.gov (United States)

    Liu, Guixiong; Zhou, Qinhe; Kuang, Yongcong; Xu, Jing; Zeng, Zhixin

    2001-09-01

    Considering that the resistance of macromolecule resistor varies in a wide range and humidity sensor component is sensitive to temperature as well, a intelligent high- precision macromolecule resistance temperature/humidity instrument was proposed in this paper, the instrument is based on the integration of frequency-and-period-measuring method, and sensing characteristic calculation and compensation using interpolation. Practical applications show that the instrument has the advantages of high precision, simple peripheral circuit, low cost, suitability for remote measurement, strong ability of anti-interference and wide operation range.

  16. Design considerations of high precision 6-HTRT parallel manipulator

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xiu-feng; SUN Li-ning

    2006-01-01

    Describes a new architecture of a parallel robot with six degrees of freedom and focuses on improving orientation accuracy of movable platform in mechanism, error correction and control methods. A set of formulations about inverse kinematics, Jacobin matrix, and forward kinematics for the high precision 6-HTRT parallel robots is presented. The analysis of errors existing in the manipulator is discussed and a novel approach for error correction is advanced. By DSP technique, inverse kinematics is solved in real time conditions with high precision and the hardware control system is given. The experimental results demonstrate the effectiveness of the proposed technique.

  17. High Precision Measurement of the differential W and Z boson cross-sections

    CERN Document Server

    Gasnikova, Ksenia; The ATLAS collaboration

    2017-01-01

    Measurements of the Drell-Yan production of W and Z/gamma bosons at the LHC provide a benchmark of our understanding of perturbative QCD and probe the proton structure in a unique way. The ATLAS collaboration has performed new high precision measurements at center-of-mass energies of 7. The measurements are performed for W+, W- and Z/gamma bosons integrated and as a function of the boson or lepton rapidity and the Z/gamma* mass. Unprecedented precision is reached and strong constraints on Parton Distribution functions, in particular the strange density are found. Z cross sections are also measured at a center-of-mass energies of 8TeV and 13TeV, and cross-section ratios to the top-quark pair production have been derived. This ratio measurement leads to a cancellation of several systematic effects and allows therefore for a high precision comparison to the theory predictions.

  18. Process influences and correction possibilities for high precision injection molded freeform optics

    Science.gov (United States)

    Dick, Lars; Risse, Stefan; Tünnermann, Andreas

    2016-08-01

    Modern injection molding processes offer a cost-efficient method for manufacturing high precision plastic optics for high volume applications. Besides form deviation of molded freeform optics, internal material stress is a relevant influencing factor for the functionality of a freeform optics in an optical system. This paper illustrates dominant influence parameters of an injection molding process relating to form deviation and internal material stress based on a freeform demonstrator geometry. Furthermore, a deterministic and efficient way for 3D mold correcting of systematic, asymmetrical shrinkage errors is shown to reach micrometer range shape accuracy at diameters up to 40 mm. In a second case, a stress-optimized parameter combination using unusual molding conditions was 3D corrected to reach high precision and low stress freeform polymer optics.

  19. High precision module for Chaos Many-Body Engine

    CERN Document Server

    Grossu, I V; Felea, D; Jipa, Al

    2014-01-01

    In this paper we present a C# high precision relativistic many-body module integrated with Chaos Many-Body Engine. As a direct application, we used it for estimating the butterfly effect involved by the gravitational force in a specific nuclear relativistic collision toy-model.

  20. Towards high precision measurements of nuclear g-factors for the Be isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Takamine, A., E-mail: icot@riken.jp [RIKEN, Nishina Center for Accelerator Based Science, Wako City, Saitama (Japan); Wada, M. [RIKEN, Nishina Center for Accelerator Based Science, Wako City, Saitama (Japan); Okada, K. [Department of Physics, Sophia University, Chiyoda Ward, Tokyo (Japan); Ito, Y. [RIKEN, Nishina Center for Accelerator Based Science, Wako City, Saitama (Japan); Schury, P.; Arai, F. [RIKEN, Nishina Center for Accelerator Based Science, Wako City, Saitama (Japan); Institute of Physics, University of Tsukuba, Tsukuba City, Ibaraki (Japan); Katayama, I. [RIKEN, Nishina Center for Accelerator Based Science, Wako City, Saitama (Japan); Imamura, K. [RIKEN, Nishina Center for Accelerator Based Science, Wako City, Saitama (Japan); Department of Physics, Meiji University, Kawasaki City, Kanagawa (Japan); Ichikawa, Y.; Ueno, H. [RIKEN, Nishina Center for Accelerator Based Science, Wako City, Saitama (Japan); Wollnik, H. [Department of Chemistry and BioChemistry, New Mexico State University, Las Cruces, NM (United States); Schuessler, H.A. [Department of Physics, Texas A& M University, College Station, TX (United States)

    2016-06-01

    We describe the present status of future high-precision measurements of nuclear g-factors utilizing laser-microwave double and laser-microwave-rf triple resonance methods for online-trapped, laser-cooled radioactive beryllium isotope ions. These methods have applicability to other suitably chosen isotopes and for beryllium show promise in deducing the hyperfine anomaly of {sup 11}Be with a sufficiently high precision to study the nuclear magnetization distribution of this one-neutron halo nucleus in a nuclear-model-independent manner.

  1. High precision modeling at the 10^{-20} level

    CERN Document Server

    Andres, M; Costea, A; Hackmann, E; Herrmann, S; Lämmerzahl, C; Nesemann, L; Rievers, B; Stephan, E P

    2011-01-01

    The requirements for accurate numerical simulation are increasing constantly. Modern high precision physics experiments now exceed the achievable numerical accuracy of standard commercial and scientific simulation tools. One example are optical resonators for which changes in the optical length are now commonly measured to 10^{-15} precision. The achievable measurement accuracy for resonators and cavities is directly influenced by changes in the distances between the optical components. If deformations in the range of 10^{-15} occur, those effects cannot be modeled and analysed any more with standard methods based on double precision data types. New experimental approaches point out that the achievable experimental accuracies may improve down to the level of 10^{-17} in the near future. For the development and improvement of high precision resonators and the analysis of experimental data, new methods have to be developed which enable the needed level of simulation accuracy. Therefore we plan the development o...

  2. Note: High precision measurements using high frequency gigahertz signals

    Science.gov (United States)

    Jin, Aohan; Fu, Siyuan; Sakurai, Atsunori; Liu, Liang; Edman, Fredrik; Pullerits, Tõnu; Öwall, Viktor; Karki, Khadga Jung

    2014-12-01

    Generalized lock-in amplifiers use digital cavities with Q-factors as high as 5 × 108 to measure signals with very high precision. In this Note, we show that generalized lock-in amplifiers can be used to analyze microwave (giga-hertz) signals with a precision of few tens of hertz. We propose that the physical changes in the medium of propagation can be measured precisely by the ultra-high precision measurement of the signal. We provide evidence to our proposition by verifying the Newton's law of cooling by measuring the effect of change in temperature on the phase and amplitude of the signals propagating through two calibrated cables. The technique could be used to precisely measure different physical properties of the propagation medium, for example, the change in length, resistance, etc. Real time implementation of the technique can open up new methodologies of in situ virtual metrology in material design.

  3. High-precision photometry by telescope defocusing - VII. The ultrashort period planet WASP-103

    DEFF Research Database (Denmark)

    Southworth, John; Mancini, L.; Ciceri, S.

    2015-01-01

    We present 17 transit light curves of the ultra-short period planetary system WASP-103, a strong candidate for the detection of tidally-induced orbital decay. We use these to establish a high-precision reference epoch for transit timing studies. The time of the reference transit midpoint is now m...

  4. Early Bronze Jericho : High-precision C-14 dates of short-lived palaeobotanic remains

    NARCIS (Netherlands)

    Bruins, HJ; Van Der Plicht, J; Mook, W.G.

    1998-01-01

    Reliable series of high-precision radiocarbon dates in a stratified archaeological context are of great importance for interdisciplinary chronological and historical studies. The Early Bronze Age in the Near East is characterized by the beginning of the great civilizations in Egypt and Mesopotamia,

  5. Design of High Precision Temperature Measurement System based on Labview

    OpenAIRE

    Weimin Zhu; Jin Liu; Haima Yang; Chaochao Yan

    2015-01-01

    Using the LabVIEW software platform, a high precision temperature measuring device is designed based on the principle of the thermocouple. The system uses the STM32 MCU as the main control chip, using AD7076 analog digital converter. The converter has 8 channel, synchronous sampling, and bipolar input. Improving the precision of temperature measurement by cold end compensation, fitting and other measures. The test results show that, the device temperature measurement precision can reach ±0.1 ...

  6. High Precision Signal Processing Algorithm for White Light Interferometry

    OpenAIRE

    Kim, Jeonggon Harrison

    2008-01-01

    A new signal processing algorithm for absolute temperature measurement using white light interferometry has been proposed and investigated theoretically. The proposed algorithm determines the phase delay of an interferometer with very high precision (≪ one fringe) by identifying the zero order fringe peak of cross-correlation of two fringe scans of white light interferometer. The algorithm features cross-correlation of interferometer fringe scans, hypothesis testing and fine tuning. The hypot...

  7. Nucleosynthesis Predictions and High-Precision Deuterium Measurements

    Directory of Open Access Journals (Sweden)

    Signe Riemer-Sørensen

    2017-05-01

    Full Text Available Two new high-precision measurements of the deuterium abundance from absorbers along the line of sight to the quasar PKS1937–1009 were presented. The absorbers have lower neutral hydrogen column densities (N(HI ≈ 18 cm − 2 than for previous high-precision measurements, boding well for further extensions of the sample due to the plenitude of low column density absorbers. The total high-precision sample now consists of 12 measurements with a weighted average deuterium abundance of D/H = 2 . 55 ± 0 . 02 × 10 − 5 . The sample does not favour a dipole similar to the one detected for the fine structure constant. The increased precision also calls for improved nucleosynthesis predictions. For that purpose we have updated the public AlterBBN code including new reactions, updated nuclear reaction rates, and the possibility of adding new physics such as dark matter. The standard Big Bang Nucleosynthesis prediction of D/H = 2 . 456 ± 0 . 057 × 10 − 5 is consistent with the observed value within 1.7 standard deviations.

  8. High-precision gas gain and energy transfer measurements in Ar–CO{sub 2} mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Şahin, Özkan, E-mail: osahin@uludag.edu.tr [Department of Physics, Uludağ University, 16059 Bursa (Turkey); Kowalski, Tadeusz Z. [Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Kraków (Poland); Veenhof, Rob [Department of Physics, Uludağ University, 16059 Bursa (Turkey); RD51 collaboration, CERN, Genève (Switzerland)

    2014-12-21

    Ar–CO{sub 2} is a Penning mixture since a fraction of the energy stored in Ar 3p{sup 5}3d and higher excited states can be transferred to ionize CO{sub 2} molecules. In the present work, concentration and pressure dependence of Penning transfer rate and photon feedback parameter in Ar–CO{sub 2} mixtures have been investigated with recent systematic high-precision gas gain measurements which cover the range 1–50% CO{sub 2} at 400, 800, 1200, 1800 hPa and gas gain from 1 to 5×10{sup 5}.

  9. High-precision gas gain and energy transfer measurements in Ar–CO2 mixtures

    CERN Document Server

    Şahin, Özkan; Veenhof, Rob

    2014-01-01

    Ar–CO2 is a Penning mixture since a fraction of the energy stored in Ar 3p53d3p53d and higher excited states can be transferred to ionize CO2 molecules. In the present work, concentration and pressure dependence of Penning transfer rate and photon feedback parameter in Ar–CO2 mixtures have been investigated with recent systematic high-precision gas gain measurements which cover the range 1–50% CO2 at 400, 800, 1200, 1800 hPa and gas gain from 1 to 5×105.

  10. High-Precision U-Pb Zircon Dates as Benchmarks in Absolute Time

    Science.gov (United States)

    Schmitz, M. D.; Bowring, S. A.; Schoene, B.

    2003-12-01

    High-precision IDTIMS U-Pb zircon dates provide the most precise and accurate isotopic benchmarks in absolute time, due to the concordancy check of the paired U-Pb decay schemes, the precisely measured 235U and 238U decay constants, very high initial parent/daughter ratios, and the robust nature of zircon to loss or gain of U and Pb over geologic time. However, caveats to the use of such zircon dates include the accurate assessment and minimization of random and systematic errors in the analytical methods, and decay constant uncertainties. Unfortunately, there exists little consensus within the U-Pb geochronological community regarding an international zircon standard for the external assessment of interlaboratory reproducibility, while residual questions remain regarding the potential for systematic error in the single available high-precision counting experiment of the U decay constants1. Stringent criteria are imposed on candidates for zircon geochronology standards including the absence of inheritance and Pb-loss at both the single grain scale and the resolution of microbeam techniques. We present an example of the potential and limitations of a possible zircon standard, AS3, from the Duluth Complex, North American Midcontinent Rift2. New data for 27 single zircons are indistinguishable from prior results, with 207Pb/206Pb and upper intercept dates identical within error to a U-Pb concordia date of 1099.1+/-0.2 Ma (+/-1.2 Ma with systematic errors) based on 12 concordant and equivalent analyses. However, we must reiterate that a zircon population exhibiting consistent concordancy remains elusive, as AS3 and all Paleozoic and older standard candidates so far examined contain grains exhibiting Pb-loss, although rigorous selection and preparation of zircons through diamagnetic separation and aggressive abrasion can mitigate this phenomenon. The continued screening of candidate standards by both IDTIMS and SHRIMP techniques should be an organized, international

  11. Seismicity analysis in Indonesia region from high precision hypocenter location

    Science.gov (United States)

    Nugraha, Andri; Shiddiqi, Hasbi; Widiyantoro, Sri; Ramdhan, Mohamad; Wandono, Wandono

    2015-04-01

    As a complex tectonic region, Indonesia has a high seismicity rate which is related to subduction and collision as well as strike-slip fault. High-precision earthquake locations with adequate relocation method and proper velocity model are necessary for seismicity analysis. We used nearly 25,000 earthquakes that were relocated using double-difference method. In our relocation process, we employed teleseismic, regional, and local P-wave arrival times. Furthermore, we employed regional-global nested velocity models that take into account the subduction slab in the study region by using a 3D model for area inside and a 1D model for area outside Indonesia. Relocation results show shifted hypocenters that are generally perpendicular to the trench. Beneath western Sunda arc, the Wadati-Benioff Zone (WBZ) extents to a depth of about 300 km and depicts a gently dipping slab. The WBZ beneath eastern Sunda arc extends deeper to about 500 km and depicts a steep slab geometry. In the Sunda-Banda transition zone, we found anomalously low seismicity beneath the oceanic-continental transition region. The WBZ of the severely curved Banda arc extends to a depth of about 600 km and depicts a two-slab model. In the Molucca collision zone, seismicity clearly depicts two opposing slabs of the Molucca sea plate, i.e. to the east and to the west. Around Sulawesi region, most earthquakes are related to the north Sulawesi trench and depict subducted slab beneath the northern part of the island. In Sumatra region, we identified a seismic gap in the WBZ between 70 km and 150 km. Seismicity gaps are also detected beneath particular regions, e.g. Mentawai region, and several parts along the subducted slab. Similar to the Sumatra region, beneath eastern Sunda arc, seismic gap in WBZ is also detected but deeper, i.e. at depths of 150 km to 250 km. Furthermore, we used global centroid moment tensor catalog data available for earthquakes with magnitude 5.0 or greater. In general, focal mechanism

  12. GENERATION AND CONTROL OF HIGH PRECISION BEAMS AT LEPTON ACCELERATORS

    Energy Technology Data Exchange (ETDEWEB)

    Yu-Chiu Chao

    2007-06-25

    Parity violation experiments require precision manipulation of helicity-correlated beam coordinates on target at the nm/nrad-level. Achieving this unprecedented level of control requires a detailed understanding of the particle optics and careful tuning of the beam transport to keep anomalies from compromising the design adiabatic damping. Such efforts are often hindered by machine configuration and instrumentation limitations at the low energy end. A technique has been developed at CEBAF including high precision measurements, Mathematica-based analysis for obtaining corrective solutions, and control hardware/software developments for realizing such level of control at energies up to 5 GeV.

  13. High precision fundamental constants at the TeV scale

    CERN Document Server

    Moch, S; Alekhin, S; Blumlein, J; de la Cruz, L; Dittmaier, S; Dowling, M; Erler, J; Espinosa, J R; Fuster, J; Tormo, X Garcia i; Hoang, A H; Huss, A; Kluth, S; Mulders, M; Papanastasiou, A S; Piclum, J; Rabbertz, K; Schwinn, C; Schulze, M; Shintani, E; Uwer, P; Zerf, N

    2014-01-01

    This report summarizes the proceedings of the 2014 Mainz Institute for Theoretical Physics (MITP) scientific program on "High precision fundamental constants at the TeV scale". The two outstanding parameters in the Standard Model dealt with during the MITP scientific program are the strong coupling constant $\\alpha_s$ and the top-quark mass $m_t$. Lacking knowledge on the value of those fundamental constants is often the limiting factor in the accuracy of theoretical predictions. The current status on $\\alpha_s$ and $m_t$ has been reviewed and directions for future research have been identified.

  14. Globular Cluster Streams as Galactic High-Precision Scales

    CERN Document Server

    Küpper, A H W; Bonaca, A; Johnston, K V; Hogg, D W; Kroupa, P; Santiago, B X

    2015-01-01

    Tidal streams of globular clusters are ideal tracers of the Galactic gravitational potential. Compared to the few known, complex and diffuse dwarf-galaxy streams, they are kinematically cold, have thin morphologies and are abundant in the halo of the Milky Way. Their coldness and thinness in combination with potential epicyclic substructure in the vicinity of the stream progenitor turns them into high-precision scales. With the example of Palomar 5, we demonstrate how modeling of a globular cluster stream allows us to simultaneously measure the properties of the disrupting globular cluster, its orbital motion, and the gravitational potential of the Milky Way.

  15. High precision photon flux determination for photon tagging experiments

    Science.gov (United States)

    Teymurazyan, A.; Ahmidouch, A.; Ambrozewicz, P.; Asratyan, A.; Baker, K.; Benton, L.; Burkert, V.; Clinton, E.; Cole, P.; Collins, P.; Dale, D.; Danagoulian, S.; Davidenko, G.; Demirchyan, R.; Deur, A.; Dolgolenko, A.; Dzyubenko, G.; Ent, R.; Evdokimov, A.; Feng, J.; Gabrielyan, M.; Gan, L.; Gasparian, A.; Glamazdin, A.; Goryachev, V.; Hardy, K.; He, J.; Ito, M.; Jiang, L.; Kashy, D.; Khandaker, M.; Kolarkar, A.; Konchatnyi, M.; Korchin, A.; Korsch, W.; Kosinov, O.; Kowalski, S.; Kubantsev, M.; Kubarovsky, V.; Larin, I.; Lawrence, D.; Li, X.; Martel, P.; Matveev, V.; McNulty, D.; Mecking, B.; Milbrath, B.; Minehart, R.; Miskimen, R.; Mochalov, V.; Nakagawa, I.; Overby, S.; Pasyuk, E.; Payen, M.; Pedroni, R.; Prok, Y.; Ritchie, B.; Salgado, C.; Shahinyan, A.; Sitnikov, A.; Sober, D.; Stepanyan, S.; Stevens, W.; Underwood, J.; Vasiliev, A.; Vishnyakov, V.; Wood, M.; Zhou, S.

    2014-12-01

    The Jefferson Laboratory PrimEx Collaboration has developed and implemented a method to control the tagged photon flux in photoproduction experiments at the 1% level over the photon energy range from 4.9 to 5.5 GeV. This method has been successfully implemented in a high precision measurement of the neutral pion lifetime. Here, we outline the experimental equipment and the analysis techniques used to accomplish this. These include the use of a total absorption counter for absolute flux calibration, a pair spectrometer for online relative flux monitoring, and a new method for post-bremsstrahlung electron counting.

  16. High-precision micro/nano-scale machining system

    Science.gov (United States)

    Kapoor, Shiv G.; Bourne, Keith Allen; DeVor, Richard E.

    2014-08-19

    A high precision micro/nanoscale machining system. A multi-axis movement machine provides relative movement along multiple axes between a workpiece and a tool holder. A cutting tool is disposed on a flexible cantilever held by the tool holder, the tool holder being movable to provide at least two of the axes to set the angle and distance of the cutting tool relative to the workpiece. A feedback control system uses measurement of deflection of the cantilever during cutting to maintain a desired cantilever deflection and hence a desired load on the cutting tool.

  17. High-precision Absolute Coordinate Measurement using Frequency Scanned Interferometry

    CERN Document Server

    Chen, Tianxiang; Riles, Keith; Li, Cheng

    2013-01-01

    In this paper, we report high-precision absolute position measurement performed with frequency scanned interferometry (FSI). We reported previously on measurement of absolute distance with FSI [1]. Absolute position is determined by several related absolute distances measured simultaneously. The achieved precision of 2-dimensional measurements is better than 1 micron, and in 3-dimensional measurements, the precision on X and Y is confirmed to be below 1 micron, while the confirmed precision on Z is about 2 microns, where the confirmation is limited by the lower precision of the moving stage in Z direction.

  18. Calibration of the TWIST high-precision drift chambers

    CERN Document Server

    Grossheim, A; Olin, A; 10.1016/j.nima.2010.08.105

    2010-01-01

    A method for the precise measurement of drift times for the high-precision drift chambers used in the TWIST detector is described. It is based on the iterative correction of the space-time relationships by the time residuals of the track fit, resulting in a measurement of the effective drift times. The corrected drift time maps are parametrised individually for each chamber using spline functions. Biases introduced by the reconstruction itself are taken into account as well, making it necessary to apply the procedure to both data and simulation. The described calibration is shown to improve the reconstruction performance and to extend significantly the physics reach of the experiment.

  19. High precision spectra at large redshift for dynamical DE cosmologies

    CERN Document Server

    Bonometto, S A; Maccio', A V; Stinson, G

    2010-01-01

    The next generation mass probes will investigate DE nature by measuring non-linear power spectra at various z, and comparing them with high precision simulations. Producing a complete set of them, taking into account baryon physics and for any DE state equation w(z), would really be numerically expensive. Regularities reducing such duty are essential. This paper presents further n-body tests of a relation we found, linking models with DE state parameter w(z) to const.-w models, and also tests the relation in hydro simulations.

  20. Strategies for high-precision Global Positioning System orbit determination

    Science.gov (United States)

    Lichten, Stephen M.; Border, James S.

    1987-01-01

    Various strategies for the high-precision orbit determination of the GPS satellites are explored using data from the 1985 GPS field test. Several refinements to the orbit determination strategies were found to be crucial for achieving high levels of repeatability and accuracy. These include the fine tuning of the GPS solar radiation coefficients and the ground station zenith tropospheric delays. Multiday arcs of 3-6 days provided better orbits and baselines than the 8-hr arcs from single-day passes. Highest-quality orbits and baselines were obtained with combined carrier phase and pseudorange solutions.

  1. High Precision Time Domain Forward Modeling for Crosshole Electromagnetic Tomography

    Institute of Scientific and Technical Information of China (English)

    Lin Shuhai; Zhao Liying

    2007-01-01

    To improve the resolution of crosshole electromagnetic tomography, high precision of forward modeling is necessary. A pseudo-spectral time domain (PSTD) forward modeling was used to simulate electromagnetic wave propagation between two boreholes. The PSTD algorithm is based on the finite difference time domain (FDTD) method and uses the fast Fourier transform (FFT) algorithm for spatial derivatives in Maxwell's equations. Besides having the strongpoint of the FDTD method, the calculation precision of the PSTD algorithm is higher than that of the FDTD method under the same calculation condition. The forward modeling using the PSTD method will play an important role in enhancing the resolution of crosshole electromagnetic tomography.

  2. High-precision methods in eigenvalue problems and their applications

    CERN Document Server

    Akulenko, Leonid D

    2004-01-01

    This book presents a survey of analytical, asymptotic, numerical, and combined methods of solving eigenvalue problems. It considers the new method of accelerated convergence for solving problems of the Sturm-Liouville type as well as boundary-value problems with boundary conditions of the first, second, and third kind. The authors also present high-precision asymptotic methods for determining eigenvalues and eigenfunctions of higher oscillation modes and consider numerous eigenvalue problems that appear in oscillation theory, acoustics, elasticity, hydrodynamics, geophysics, quantum mechanics, structural mechanics, electrodynamics, and microelectronics.

  3. Automated high precision secondary pH measurements

    Science.gov (United States)

    Bastkowski, F.; Jakobsen, P. T.; Stefan, F.; Kristensen, H. B.; Jensen, H. D.; Kawiecki, R.; Wied, C. E.; Kauert, A.; Seidl, B.; Spitzer, P.; Eberhardt, R.; Adel, B.

    2013-04-01

    A new setup for high precision, automated secondary pH measurements together with a reference measurement procedure has been developed and tested in interlaboratory comparisons using buffers pH 4.005, pH 7.000, and pH 10.012 at 25 °C and 37 °C. Using primary buffers as standards, a standard uncertainty in pH better than 0.005 can be reached. The central measuring device is a one piece, thermostatted cell of PFA (perfluoroalkoxy) with a built-in Hamilton® Single Pore™ Glass electrode. Due to its flow-through principle this device allows pH measurements with low consumption of measurement solutions. The very hydrophobic and smooth PFA as construction material facilitates complete emptying of the cell. Furthermore, the tempering unit affords very precise temperature control and hence contributes to the low target uncertainty of the produced secondary buffer solutions. Use of a symmetric measurement sequence and the two point calibration was sufficient to reach high precision and accuracy.

  4. High Precision Signal Processing Algorithm for White Light Interferometry

    Directory of Open Access Journals (Sweden)

    Jeonggon Harrison Kim

    2008-12-01

    Full Text Available A new signal processing algorithm for absolute temperature measurement using white light interferometry has been proposed and investigated theoretically. The proposed algorithm determines the phase delay of an interferometer with very high precision (<< one fringe by identifying the zero order fringe peak of cross-correlation of two fringe scans of white light interferometer. The algorithm features cross-correlation of interferometer fringe scans, hypothesis testing and fine tuning. The hypothesis test looks for a zero order fringe peak candidate about which the cross-correlation is symmetric minimizing the uncertainty of mis-identification. Fine tuning provides the proposed algorithm with high precision subsample resolution phase delay estimation capability. The shot noise limited performance of the proposed algorithm has been analyzed using computer simulations. Root-mean-square (RMS phase error of the estimated zero order fringe peak has been calculated for the changes of three different parameters (SNR, fringe scan sample rate, coherence length of light source. Computer simulations showed that the proposed signal processing algorithm identified the zero order fringe peak with a miss rate of 3 x 10-4 at 31 dB SNR and the extrapolated miss rate at 35 dB was 3 x 10-8. Also, at 35 dB SNR, RMS phase error less than 10-3 fringe was obtained. The proposed signal processing algorithm uses a software approach that is potentially inexpensive, simple and fast.

  5. The development of high precision carbon fiber composite mirror

    Science.gov (United States)

    Xu, Liang; Ding, Jiao-teng; Wang, Yong-jie; Xie, Yong-jie; Ma, Zhen; Fan, Xue-wu

    2016-10-01

    Due to low density, high stiffness, low thermal expansion coefficient, duplicate molding, etc., carbon fiber reinforced polymer (CFRP) is one of the potential materials of the optical mirror. The process developed for Φ300mm high precision CFRP mirror described in this paper. A placement tool used to improve laying accuracy up to ± 0.1°.A special reinforced cell structure designed to increase rigidity and thermal stability. Optical replication process adopted for surface modification of the carbon fiber composite mirror blank. Finally, surface accuracy RMS of Φ300mm CFRP mirror is 0.22μm, surface roughness Ra is about 2nm, and the thermal stability can achieve 13nm /°C from the test result. The research content is of some reference value in the infrared as well as visible light applications.

  6. Computer Controlled High Precise,High Voltage Pules Generator

    Institute of Scientific and Technical Information of China (English)

    但果; 邹积岩; 丛吉远; 董恩源

    2003-01-01

    High precise, high voltage pulse generator made up of high-power IGBT and pulse transformers controlled by a computer are described. A simple main circuit topology employed in this pulse generator can reduce the cost meanwhile it still meets special requirements for pulsed electric fields (PEFs) in food process. The pulse generator utilizes a complex programmable logic device (CPLD) to generate trigger signals. Pulse-frequency, pulse-width and pulse-number are controlled via RS232 bus by a computer. The high voltage pulse generator well suits to the application for fluid food non-thermal effect in pulsed electric fields, for it can increase and decrease by the step length 1.

  7. A high-precision control system for robotic welding positioner

    Institute of Scientific and Technical Information of China (English)

    Shi Yu; Fan Ding; Chen Jianhong

    2005-01-01

    Aiming at the robotic welding positioner with characteristic of parameter change, load change, nonlinearity, and an intelligent control system was researched and developed. This control system used a two-mode controller that based on Fuzzy and PID control method. The results of simulation show that the dynamic and steady performances of the intelligent controller are better than that of single PID or Fuzzy controller. This paper has made a detail theoretical analysis of the constitution design and real-time controlled software and brought up the design and fulfillment method of multi-task real-time control software of high precisely and numerically controlled welding positioner , which has a good result in practice.

  8. A detector interferometric calibration experiment for high precision astrometry

    CERN Document Server

    Crouzier, A; Henault, F; Leger, A; Cara, C; LeDuigou, J M; Preis, O; Kern, P; Delboulbe, A; Martin, G; Feautrier, P; Stadler, E; Lafrasse, S; Rochat, S; Ketchazo, C; Donati, M; Doumayrou, E; Lagage, P O; Shao, M; Goullioud, R; Nemati, B; Zhai, C; Behar, E; Potin, S; Saint-Pe, M; Dupont, J

    2016-01-01

    Context: Exoplanet science has made staggering progress in the last two decades, due to the relentless exploration of new detection methods and refinement of existing ones. Yet astrometry offers a unique and untapped potential of discovery of habitable-zone low-mass planets around all the solar-like stars of the solar neighborhood. To fulfill this goal, astrometry must be paired with high precision calibration of the detector. Aims: We present a way to calibrate a detector for high accuracy astrometry. An experimental testbed combining an astrometric simulator and an interferometric calibration system is used to validate both the hardware needed for the calibration and the signal processing methods. The objective is an accuracy of 5e-6 pixel on the location of a Nyquist sampled polychromatic point spread function. Methods: The interferometric calibration system produced modulated Young fringes on the detector. The Young fringes were parametrized as products of time and space dependent functions, based on vari...

  9. Test results of high-precision large cryogenic lens holders

    Science.gov (United States)

    Gal, C.; Reutlinger, A.; Boesz, A.; Leberle, T.; Mottaghibonab, A.; Eckert, P.; Dubowy, M.; Gebler, H.; Grupp, F.; Geis, N.; Bode, A.; Katterloher, R.; Bender, R.

    2012-09-01

    For the Euclid mission a Pre-Development phase is implemented to prove feasibility of individual components of the system [1]. The Near Infrared Spectrometer and Photometer (NISP) of EUCLID requires high precision large lens holders (?170 mm) at cryogenic temperatures (150K). The four lenses of the optical system are made of different materials: fused silica, CaF2, and LF5G15 that are mounted in a separate lens barrel design. Each lens has its separate mechanical interface to the lens barrel, the so called adaption ring. The performance of the lens holder design is verified by adapted test equipment and test facility including an optical metrology system. The characterization of the lens deformation and displacement (decenter, tilt) due to mechanical loads of the holder itself as well as thermally induced loads are driven by the required submicron precision range and the operational thermal condition. The surface deformation of the lens and its holder is verified by interferometric measurements, while tilt and position accuracy are measured by in-situ fibre based distance sensors. The selected distance measurement sensors have the capability to measure in a few mm range with submicron resolution in ultra high vacuum, in vibration environments and at liquid nitrogen temperatures and below. The calibration of the measurement system is of crucial importance: impacts such as temperature fluctuation, surface roughness, surface reflectivity, straylight effects, etc. on the measured distance are carefully calibrated. Inbuilt thermal expansion effects of the fibre sensors are characterized and proven with lens dummy with quasi zero CTE. The paper presents the test results and measured performance of the high precision large cryogenic lens holders attained by the metrology system. These results are presented on behalf of the EUCLID consortium.

  10. High-Precision Mass Measurements of Exotic Nuclei with the Triple-Trap Mass Spectrometer Isoltrap

    CERN Multimedia

    Blaum, K; Zuber, K T; Stanja, J

    2002-01-01

    The masses of close to 200 short-lived nuclides have already been measured with the mass spectrometer ISOLTRAP with a relative precision between 1$\\times$10$^{-7}$ and 1$\\times$10^{-8}$. The installatin of a radio-frequency quadrupole trap increased the overall efficiency by two orders of magnitude which is at present about 1%. In a recent upgrade, we installed a carbon cluster laser ion source, which will allow us to use carbon clusters as mass references for absolute mass measurements. Due to these improvements and the high reliability of ISOLTRAP we are now able to perform accurate high-precision mass measurements all over the nuclear chart. We propose therefore mass measurements on light, medium and heavy nuclides on both sides of the valley of stability in the coming four years. ISOLTRAP is presently the only instrument capable of the high precision required for many of the proposed studies.

  11. A High-precision Motion Compensation Method for SAR Based on Image Intensity Optimization

    Directory of Open Access Journals (Sweden)

    Hu Ke-bin

    2015-02-01

    Full Text Available Owing to the platform instability and precision limitations of motion sensors, motion errors negatively affect the quality of synthetic aperture radar (SAR images. The autofocus Back Projection (BP algorithm based on the optimization of image sharpness compensates for motion errors through phase error estimation. This method can attain relatively good performance, while assuming the same phase error for all pixels, i.e., it ignores the spatial variance of motion errors. To overcome this drawback, a high-precision motion error compensation method is presented in this study. In the proposed method, the Antenna Phase Centers (APC are estimated via optimization using the criterion of maximum image intensity. Then, the estimated APCs are applied for BP imaging. Because the APC estimation equals the range history estimation for each pixel, high-precision phase compensation for every pixel can be achieved. Point-target simulations and processing of experimental data validate the effectiveness of the proposed method.

  12. Quality of silicon convex lenses fabricated by ultra-high precision diamond machining

    Directory of Open Access Journals (Sweden)

    Abou-El-Hossein, K.

    2013-05-01

    Full Text Available Infra-red optical components are made mainly from hard and brittle materials such as germanium and silicon. Silicon machining is characterised by some difficulties when ultra-high precision machined by mono-crystalline single-point diamond. Accelerated tool wear and machined-surface deterioration may take place if the machining parameters are not properly selected. In this study, we conducted a machining test on an ultra-high precision machine tool, using ductile regime cutting conditions when fabricating a convex surface on a silicon lens of aperture of 60 mm diameter, and using a mono-crystalline diamond. It was found that the cutting conditions for shaping a convex surface of 500 mm radius resulted in good form accuracy. However, more attention should be paid to optimising the holding force of the vacuum chuck employed.

  13. High-precision gravity network to monitor temporal variations in gravity across Yucca Mountain, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Harris, R.N.; Ponce, D.A.

    1988-12-31

    Repeatable high-precision gravity surveys provide a method of monitoring temporal variations in the gravity field. Fluctuations in the gravity field may indicate water table changes, crustal deformation, or precursors to volcanism and earthquakes. This report describes a high-precision gravity loop which has been established across Yucca Mountain, Nevada in support of the Nevada Nuclear Waste Storage Investigations (NNWSI) program. The purpose of this gravity loop is to monitor temporal variations in gravity across Yucca Mountain in an effort to interpret and predict the stability of the tectonic framework and changes in the subsurface density field. Studies of the tectonic framework which include volcanic hazard seismicity, and faulting studies are in progress. Repeat high-precision gravity surveys are less expensive and can be made more rapidly than a corresponding leveling survey. High-precision gravity surveys are capable of detecting elevation changes of 3 to 5 cm, and thus can be employed as an efficient tool for monitoring vertical crustal movements while supplementing or partially replacing leveling data. The Yucca Mountain gravity network has been tied to absolute gravity measurements established in southern Nevada. These ties provide an absolute datum for comparing repeat occupations of the gravity network, and provide a method of monitoring broad-scale changes in gravity. Absolute gravity measurements were also made at the bottom and top of the Charleston Peak calibration loop in southern Nevada. These absolute gravity measurements provide local control of calibrating gravity meters over the gravity ranges observed at Yucca Mountain. 13 refs., 7 figs., 3 tabs.

  14. High Precision Measurement of the differential vector boson cross-sections with the ATLAS detector

    CERN Document Server

    Armbruster, Aaron James; The ATLAS collaboration

    2017-01-01

    Measurements of the Drell-Yan production of W and Z/gamma bosons at the LHC provide a benchmark of our understanding of perturbative QCD and probe the proton structure in a unique way. The ATLAS collaboration has performed new high precision measurements at center-of-mass energies of 7. The measurements are performed for W+, W- and Z/gamma bosons integrated and as a function of the boson or lepton rapidity and the Z/gamma* mass. Unprecedented precision is reached and strong constraints on Parton Distribution functions, in particular the strange density are found. Z cross sections are also measured at center-of-mass energies of 8 eV and 13TeV, and cross-section ratios to the top-quark pair production have been derived. This ratio measurement leads to a cancellation of systematic effects and allows for a high precision comparison to the theory predictions. The cross section of single W events has also been measured precisely at center-of-mass energies of 8TeV and 13TeV and the W charge asymmetry has been determ...

  15. Radio emission from Supernovae and High Precision Astrometry

    Science.gov (United States)

    Perez-Torres, M. A.

    1999-11-01

    The present thesis work makes contributions in two scientific fronts: differential astrometry over the largest angular scales ever attempted (approx. 15 arcdegrees) and numerical simulations of radio emission from very young supernovae. In the first part, we describe the results of the use of very-long-baseline interferometry (VLBI) in one experiment designed to measure with very high precision the angular distance between the radio sources 1150+812 (QSO) and 1803+784 (BL Lac). We observed the radio sources on 19 November 1993 using an intercontinental array of radio telescopes, which simultaneously recorded at 2.3 and 8.4 GHz. VLBI differential astrometry is capable, Nature allowing, of yielding source positions with precisions well below the milliarcsecond level. To achieve this precision, we first had to accurately model the rotation of the interferometric fringes via the most precise models of Earth Orientation Parameters (EOP; precession, polar motion and UT1, nutation). With this model, we successfully connected our phase delay data at both frequencies and, using difference astrometric techniques, determined the coordinates of 1803+784 relative to those of 1150+812-within the IERS reference frame--with an standard error of about 0.6 mas in each coordinate. We then corrected for several effects including propagation medium (mainly the atmosphere and ionosphere), and opacity and source-structure effects within the radio sources. We stress that our dual-frequency measurements allowed us to accurately subtract the ionosphere contribution from our data. We also used GPS-based TEC measurements to independently find the ionosphere contribution, and showed that these contributions agree with our dual-frequency measurements within about 2 standard deviations in the less favorables cases (the longest baselines), but are usually well within one standard deviation. Our estimates of the relative positions, whether using dual-frequency-based or GPS-based ionosphere

  16. High Precision Sunphotometer using Wide Dynamic Range (WDR) Camera Tracking

    Science.gov (United States)

    Liss, J.; Dunagan, S. E.; Johnson, R. R.; Chang, C. S.; LeBlanc, S. E.; Shinozuka, Y.; Redemann, J.; Flynn, C. J.; Segal-Rosenhaimer, M.; Pistone, K.; Kacenelenbogen, M. S.; Fahey, L.

    2016-12-01

    High Precision Sunphotometer using Wide Dynamic Range (WDR) Camera TrackingThe NASA Ames Sun-photometer-Satellite Group, DOE, PNNL Atmospheric Sciences and Global Change Division, and NASA Goddard's AERONET (AErosol RObotic NETwork) team recently collaborated on the development of a new airborne sunphotometry instrument that provides information on gases and aerosols extending far beyond what can be derived from discrete-channel direct-beam measurements, while preserving or enhancing many of the desirable AATS features (e.g., compactness, versatility, automation, reliability). The enhanced instrument combines the sun-tracking ability of the current 14-Channel NASA Ames AATS-14 with the sky-scanning ability of the ground-based AERONET Sun/sky photometers, while extending both AATS-14 and AERONET capabilities by providing full spectral information from the UV (350 nm) to the SWIR (1,700 nm). Strengths of this measurement approach include many more wavelengths (isolated from gas absorption features) that may be used to characterize aerosols and detailed (oversampled) measurements of the absorption features of specific gas constituents. The Sky Scanning Sun Tracking Airborne Radiometer (3STAR) replicates the radiometer functionality of the AATS-14 instrument but incorporates modern COTS technologies for all instruments subsystems. A 19-channel radiometer bundle design is borrowed from a commercial water column radiance instrument manufactured by Biospherical Instruments of San Diego California (ref, Morrow and Hooker)) and developed using NASA funds under the Small Business Innovative Research (SBIR) program. The 3STAR design also incorporates the latest in robotic motor technology embodied in Rotary actuators from Oriental motor Corp. having better than 15 arc seconds of positioning accuracy. Control system was designed, tested and simulated using a Hybrid-Dynamical modeling methodology. The design also replaces the classic quadrant detector tracking sensor with a

  17. Key techniques of the high precision gravity field system

    Science.gov (United States)

    Xu, Weimin; Chen, Shi; Lu, Hongyan; Shi, Lei

    2017-04-01

    Ground-based gravity time series provide a direct method to monitor all sources of mass changes from local to global scale. But the effectively infinite spatial sensitivity of gravity measurements make it difficult to isolate the signal of interest. The high precision gravity field system is an alternative approach of modeling mass changes under-ground. The field system, consists of absolute gravity, gravity and gravity gradient, GNSS, leveling and climate hydrology measurements, can improve the signal-to-noise ratio for many applications by removing contributions of unwanted signal from elevation changes, air pressure changes, local hydrology, and others. The networks of field system combination, such as field-profile in more than 100 kilometers, can be used in critical zone with high seismic risk for monitoring earth dynamics, volcanic and seismic phenomena. The system is constituted by 9 typical observation stations in 3*3 array (or 4 in 2*2 array) in 60 square meters field, each station is designed for integrated measurements, including absolute gravity, gravity gradient, elevation changes, air pressure and hydrology. Time-lapse gravity changes resulting from absolute gravimeter (FG5 or A10) with standard deviation less than 2 μGal, without the contributions of Earth tides, loading and polar motion. Additional measurements such as air pressure change, local hydrology and soil moisture are indispensable. The elevation changes resulting from GNSS (on the base station) and leveling (between stations) with precision less than 10 mm. The gravity gradient is the significant measurement for delimiting the location of the related mass changes underground the station, which is measured by Scintrex CG-5 gravimeters in different height (80cm in the test field), with precision less than 10 E. It is necessary to improve the precision of gravity gradient measurements by certain method in field experiment for the high precision measurement system. Acknowledgment: This

  18. Silicon Avalanche Pixel Sensor for High Precision Tracking

    CERN Document Server

    D'Ascenzo, N; Moon, C S; Morsani, F; Ratti, L; Saveliev, V; Navarro, A Savoy; Xie, Q

    2013-01-01

    The development of an innovative position sensitive pixelated sensor to detect and measure with high precision the coordinates of the ionizing particles is proposed. The silicon avalanche pixel sensors (APiX) is based on the vertical integration of avalanche pixels connected in pairs and operated in coincidence in fully digital mode and with the processing electronics embedded on the chip. The APiX sensor addresses the need to minimize the material budget and related multiple scattering effects in tracking systems requiring a high spatial resolution in the presence of a large occupancy. The expected operation of the new sensor features: low noise, low power consumption and suitable radiation tolerance. The APiX device provides on-chip digital information on the position of the coordinate of the impinging charged particle and can be seen as the building block of a modular system of pixelated arrays, implementing a sparsified readout. The technological challenges are the 3D integration of the device under CMOS ...

  19. Highly precise and compact ultrahigh vacuum rotary feedthrough

    Science.gov (United States)

    Aiura, Y.; Kitano, K.

    2012-03-01

    The precision and rigidity of compact ultrahigh vacuum (UHV) rotary feedthroughs were substantially improved by preparing and installing an optimal crossed roller bearing with mounting holes. Since there are mounting holes on both the outer and inner races, the bearing can be mounted directly to rotary and stationary stages without any fixing plates and housing. As a result, it is possible to increase the thickness of the bearing or the size of the rolling elements in the bearing without increasing the distance between the rotating and fixing International Conflat flanges of the UHV rotary feedthrough. Larger rolling elements enhance the rigidity of the UHV rotary feedthrough. Moreover, owing to the structure having integrated inner and outer races and mounting holes, the performance is almost entirely unaffected by the installation of the bearing, allowing for a precise optical encoder to be installed in the compact UHV rotary feedthrough. Using position feedback via a worm gear system driven by a stepper motor and a precise rotary encoder, the actual angle of the compact UHV rotary feedthrough can be controlled with extremely high precision.

  20. High-precision experiments on a single trapped radium ion

    Energy Technology Data Exchange (ETDEWEB)

    Boell, O.; Giri, G.S.; Jungmann, K.; Sahoo, B.K.; Timmermans, R.G.E.; Versolato, O.O.; Wansbeek, L.W.; Willmann, L. [KVI, University of Groningen (Netherlands)

    2009-07-01

    A single, trapped radium ion is an ideal candidate for high precision experiments. Two Ra{sup +} experiments are under construction at KVI. Ultra-narrow transitions in radium ions provide an excellent basis for an all-optical, high-stability frequency standard, i.e. a clock. The off-the-shelf availability of semiconductor lasers for all necessary transitions is highly advantageous. In certain odd isotopes of radium, the nuclear electric quadrupole shift is absent. The same system and experimental hardware will be used to search for physics beyond the Standard Model of particle physics by measuring Atomic Parity Violation. This will serve as a low-energy test of the running of the electroweak mixing angle. Recent calculations have shown Ra{sup +} to be the superior candidate. Recently we have succeeded in the production and efficient slowing down of isotopes around {sup 213}Ra at the AGOR cyclotron and the TRI{mu}P facility of KVI. Progress has been made in the development of ion traps and in the laser set-up in a dedicated laser laboratory. Laser spectroscopy of the radium ion and the first ever trapping of this particle are planned in the near future.

  1. Fast, High-Precision Readout Circuit for Detector Arrays

    Science.gov (United States)

    Rider, David M.; Hancock, Bruce R.; Key, Richard W.; Cunningham, Thomas J.; Wrigley, Chris J.; Seshadri, Suresh; Sander, Stanley P.; Blavier, Jean-Francois L.

    2013-01-01

    The GEO-CAPE mission described in NASA's Earth Science and Applications Decadal Survey requires high spatial, temporal, and spectral resolution measurements to monitor and characterize the rapidly changing chemistry of the troposphere over North and South Americas. High-frame-rate focal plane arrays (FPAs) with many pixels are needed to enable such measurements. A high-throughput digital detector readout integrated circuit (ROIC) that meets the GEO-CAPE FPA needs has been developed, fabricated, and tested. The ROIC is based on an innovative charge integrating, fast, high-precision analog-to-digital circuit that is built into each pixel. The 128×128-pixel ROIC digitizes all 16,384 pixels simultaneously at frame rates up to 16 kHz to provide a completely digital output on a single integrated circuit at an unprecedented rate of 262 million pixels per second. The approach eliminates the need for off focal plane electronics, greatly reducing volume, mass, and power compared to conventional FPA implementations. A focal plane based on this ROIC will require less than 2 W of power on a 1×1-cm integrated circuit. The ROIC is fabricated of silicon using CMOS technology. It is designed to be indium bump bonded to a variety of detector materials including silicon PIN diodes, indium antimonide (InSb), indium gallium arsenide (In- GaAs), and mercury cadmium telluride (HgCdTe) detector arrays to provide coverage over a broad spectral range in the infrared, visible, and ultraviolet spectral ranges.

  2. High precision refractometry based on Fresnel diffraction from phase plates.

    Science.gov (United States)

    Tavassoly, M Taghi; Naraghi, Roxana Rezvani; Nahal, Arashmid; Hassani, Khosrow

    2012-05-01

    When a transparent plane-parallel plate is illuminated at a boundary region by a monochromatic parallel beam of light, Fresnel diffraction occurs because of the abrupt change in phase imposed by the finite change in refractive index at the plate boundary. The visibility of the diffraction fringes varies periodically with changes in incident angle. The visibility period depends on the plate thickness and the refractive indices of the plate and the surrounding medium. Plotting the phase change versus incident angle or counting the visibility repetition in an incident-angle interval provides, for a given plate thickness, the refractive index of the plate very accurately. It is shown here that the refractive index of a plate can be determined without knowing the plate thickness. Therefore, the technique can be utilized for measuring plate thickness with high precision. In addition, by installing a plate with known refractive index in a rectangular cell filled with a liquid and following the described procedures, the refractive index of the liquid is obtained. The technique is applied to measure the refractive indices of a glass slide, distilled water, and ethanol. The potential and merits of the technique are also discussed.

  3. Photonic systems for high precision radial velocity measurements

    Science.gov (United States)

    Halverson, Samuel

    2016-01-01

    I will discuss new instrumentation and techniques designed to maximize the Doppler radial velocity (RV) measurement precision of next generation exoplanet discovery instruments. These systems include a novel wavelength calibration device based on an all-fiber fabry-perot interferometer, a compact and efficient optical fiber image scrambler based on a single high-index ball lens, and a unique optical fiber mode mixer. These systems have been developed specifically to overcome three technological hurdles that have classically hindered high precision RV measurements in both the optical and near-infrared (NIR), namely: lack of available wavelength calibration sources, inadequate decoupling of the spectrograph from variable telescope illumination, and speckle-induced noise due to mode interference in optical fibers. The instrumentation presented here will be applied to the Habitable-zone Planet Finder, a NIR RV instrument designed to detect rocky planets orbiting in the habitable zones of nearby M-dwarfs, and represents a critical technological step towards the detection of potentially habitable Earth-like planets. While primarily focused in the NIR, many of these systems will be adapted to future optical RV instruments as well, such as NASA's new Extreme Precision Doppler Spectrometer for the WIYN telescope.

  4. High precision optomechanical assembly using threads as mechanical reference

    Science.gov (United States)

    Lamontagne, Frédéric; Desnoyers, Nichola; Bergeron, Guy; Cantin, Mario

    2016-09-01

    A convenient method to assemble optomechanical components is to use threaded interface. For example, lenses are often secured inside barrels using threaded rings. In other cases, multiple optical sub-assemblies such as lens barrels can be threaded to each other. Threads have the advantage to provide a simple assembly method, to be easy to manufacture, and to offer a compact mechanical design. On the other hand, threads are not considered to provide accurate centering between parts because of the assembly clearance between the inner and outer threads. For that reason, threads are often used in conjunction with precision cylindrical surfaces to limit the radial clearance between the parts to be centered. Therefore, tight manufacturing tolerances are needed on these pilot diameters, which affect the cost of the optical assembly. This paper presents a new optomechanical approach that uses threads as mechanical reference. This innovative method relies on geometric principles to auto-center parts to each other with a very low centering error that is usually less than 5 μm. The method allows to auto-center an optical group in a main barrel, to perform an axial adjustment of an optical group inside a main barrel, and to perform stacking of multiple barrels. In conjunction with the lens auto-centering method that also used threads as a mechanical reference, this novel solution opens new possibilities to realize a variety of different high precision optomechanical assemblies at lower cost.

  5. High precision measurement of electrical resistance across endothelial cell monolayers.

    Science.gov (United States)

    Tschugguel, W; Zhegu, Z; Gajdzik, L; Maier, M; Binder, B R; Graf, J

    1995-05-01

    Effects of vasoactive agonists on endothelial permeability was assessed by measurement of transendothelial electrical resistance (TEER) of human umbilical vein endothelial cells (HUVECs) grown on porous polycarbonate supports. Because of the low values of TEER obtained in this preparation (< 5 omega cm2) a design of an Ussing type recording chamber was chosen that provided for a homogeneous electric field across the monolayer and for proper correction of series resistances. Precision current pulses and appropriate rates of sampling and averaging of the voltage signal allowed for measurement of < 0.1 omega resistance changes of the endothelium on top of a 21 omega series resistance of the support and bathing fluid layers. Histamine (10 microM) and thrombin (10 U/ml) induced an abrupt and substantial decrease of TEER, bradykinin (1 microM) was less effective, PAF (380 nM) and LTC4 (1 microM) had no effect. TEER was also reduced by the calcium ionophore A-23187 (10 microM). The technique allows for measurements of TEER in low resistance monolayer cultures with high precision and time resolution. The results obtained extend previous observations in providing quantitative data on the increase of permeability of HUVECs in response to vasoactive agonists.

  6. A portable laser system for high precision atom interferometry experiments

    CERN Document Server

    Schmidt, Malte; Giorgini, Antonio; Tino, Guglielmo M; Peters, Achim

    2010-01-01

    We present a modular rack-mounted laser system for the cooling and manipulation of neutral rubidium atoms which has been developed for the portable gravimeter GAIN, an atom interferometer that will be capable of performing high precision gravity measurements directly at sites of geophysical interest. This laser system is designed to be compact, mobile and robust, yet it still offers improvements over many conventional laboratory-based laser systems. Our system is contained in a standard 19" rack and emits light at five different wavelengths simultaneously on up to 12 fibre ports at a total output power of 800 mW. These wavelengths can be changed and switched between ports in less than a microsecond. The setup includes two phase-locked Raman lasers with a phase noise spectral density of less than 1 \\mu rad/sqrt(Hz) in the frequency range in which our gravimeter is most sensitive to noise. We characterize this laser system and evaluate the performance limits it imposes on an interferometer.

  7. New research trends on high-precision time transfer technology

    Institute of Scientific and Technical Information of China (English)

    DONG; Ruifang; QUAN; Run’ai; HOU; Feiyan; WANG; Shaofeng; XIANG; Xiao; ZHOU; Conghua; WANG; Mengmeng; LIU; Tao; ZHANG; Shou’gang

    2015-01-01

    High-precision time transfer plays an important role in the areas of fundamental research and applications. Accompanying w ith the remarkable improvements in the ability of generating and measuring high-accuracy time-frequency signal,seeking for new time-transfer techniques betw een distant clocks w ith much further improved accuracy attracts attentions w orld-w idely. The time-transfer technique based on optical pulses has the highest precision presently,and the further improvement in the accuracy is heavily dependent on the time-domain properties of the pulse as w ell as the sensitivity of the applied measurement on the exchanged pulse. The application of optical frequency comb in time transfer for a precision up to femtosecond level are currently the focus of much interest,and has recently achieved many breakthroughs. Further investigations show that,utilizing quantum techniques,i.e. quantum measurement technique and quantum optical pulse source,can lead to a new limit on the measured timing information. Furthermore,it can be immune from atmospheric parameters,such as pressure,temperature,humidity and so on.Such quantum improvements on time-transfer have a bright prospect in the future applications requiring extremely high-accuracy timing and ranging. The potential achievements w ill form a technical basis for the future realization of sub-femtosecond time transfer system.

  8. HIGH PRECISION ROVIBRATIONAL SPECTROSCOPY OF OH{sup +}

    Energy Technology Data Exchange (ETDEWEB)

    Markus, Charles R.; Hodges, James N.; Perry, Adam J.; Kocheril, G. Stephen; McCall, Benjamin J. [Department of Chemistry, University of Illinois, Urbana, IL 61801 (United States); Müller, Holger S. P., E-mail: bjmccall@illinois.edu [I. Physikalisches Institut, Universität zu Köln, Zülpicher Str. 77, D-50937 Köln (Germany)

    2016-02-01

    The molecular ion OH{sup +} has long been known to be an important component of the interstellar medium. Its relative abundance can be used to indirectly measure cosmic ray ionization rates of hydrogen, and it is the first intermediate in the interstellar formation of water. To date, only a limited number of pure rotational transitions have been observed in the laboratory making it necessary to indirectly calculate rotational levels from high-precision rovibrational spectroscopy. We have remeasured 30 transitions in the fundamental band with MHz-level precision, in order to enable the prediction of a THz spectrum of OH{sup +}. The ions were produced in a water cooled discharge of O{sub 2}, H{sub 2}, and He, and the rovibrational transitions were measured with the technique Noise Immune Cavity Enhanced Optical Heterodyne Velocity Modulation Spectroscopy. These values have been included in a global fit of field free data to a {sup 3}Σ{sup −} linear molecule effective Hamiltonian to determine improved spectroscopic parameters which were used to predict the pure rotational transition frequencies.

  9. High precision measurements of the diamond Hugoniot in and above the melt region

    Energy Technology Data Exchange (ETDEWEB)

    Hicks, D; Boehly, T; Celliers, P; Bradley, D; Eggert, J; McWilliams, R S; Collins, G

    2008-08-05

    High precision laser-driven shock wave measurements of the diamond principal Hugoniot have been made at pressures between 6 and 19 Mbar. Shock velocities were determined with 0.3-1.1% precision using a velocity interferometer. Impedance matching analysis, incorporating systematic errors in the equation-of-state of the quartz standard, was used to determine the Hugoniot with 1.2-2.7% precision in density. The results are in good agreement with published ab initio calculations which predict a small negative melt slope along the Hugoniot, but disagree with previous laser-driven shock wave experiments which had observed a large density increase in the melt region. In the extensive solid-liquid coexistence regime between 6 and 10 Mbar these measurements indicate that the mixed phase may be slightly more dense than would be expected from a simple interpolation between liquid and solid Hugoniots.

  10. A detector interferometric calibration experiment for high precision astrometry

    Science.gov (United States)

    Crouzier, A.; Malbet, F.; Henault, F.; Léger, A.; Cara, C.; LeDuigou, J. M.; Preis, O.; Kern, P.; Delboulbe, A.; Martin, G.; Feautrier, P.; Stadler, E.; Lafrasse, S.; Rochat, S.; Ketchazo, C.; Donati, M.; Doumayrou, E.; Lagage, P. O.; Shao, M.; Goullioud, R.; Nemati, B.; Zhai, C.; Behar, E.; Potin, S.; Saint-Pe, M.; Dupont, J.

    2016-11-01

    Context. Exoplanet science has made staggering progress in the last two decades, due to the relentless exploration of new detection methods and refinement of existing ones. Yet astrometry offers a unique and untapped potential of discovery of habitable-zone low-mass planets around all the solar-like stars of the solar neighborhood. To fulfill this goal, astrometry must be paired with high precision calibration of the detector. Aims: We present a way to calibrate a detector for high accuracy astrometry. An experimental testbed combining an astrometric simulator and an interferometric calibration system is used to validate both the hardware needed for the calibration and the signal processing methods. The objective is an accuracy of 5 × 10-6 pixel on the location of a Nyquist sampled polychromatic point spread function. Methods: The interferometric calibration system produced modulated Young fringes on the detector. The Young fringes were parametrized as products of time and space dependent functions, based on various pixel parameters. The minimization of function parameters was done iteratively, until convergence was obtained, revealing the pixel information needed for the calibration of astrometric measurements. Results: The calibration system yielded the pixel positions to an accuracy estimated at 4 × 10-4 pixel. After including the pixel position information, an astrometric accuracy of 6 × 10-5 pixel was obtained, for a PSF motion over more than five pixels. In the static mode (small jitter motion of less than 1 × 10-3 pixel), a photon noise limited precision of 3 × 10-5 pixel was reached.

  11. Developing Performance Estimates for High Precision Astrometry with TMT

    Science.gov (United States)

    Schoeck, Matthias; Do, Tuan; Ellerbroek, Brent; Herriot, Glen; Meyer, Leo; Suzuki, Ryuji; Wang, Lianqi; Yelda, Sylvana

    2013-12-01

    Adaptive optics on Extremely Large Telescopes will open up many new science cases or expand existing science into regimes unattainable with the current generation of telescopes. One example of this is high-precision astrometry, which has requirements in the range from 10 to 50 micro-arc-seconds for some instruments and science cases. Achieving these requirements imposes stringent constraints on the design of the entire observatory, but also on the calibration procedures, observing sequences and the data analysis techniques. This paper summarizes our efforts to develop a top down astrometry error budget for TMT. It is predominantly developed for the first-light AO system, NFIRAOS, and the IRIS instrument, but many terms are applicable to other configurations as well. Astrometry error sources are divided into 5 categories: Reference source and catalog errors, atmospheric refraction correction errors, other residual atmospheric effects, opto-mechanical errors and focal plane measurement errors. Results are developed in parametric form whenever possible. However, almost every error term in the error budget depends on the details of the astrometry observations, such as whether absolute or differential astrometry is the goal, whether one observes a sparse or crowded field, what the time scales of interest are, etc. Thus, it is not possible to develop a single error budget that applies to all science cases and separate budgets are developed and detailed for key astrometric observations. Our error budget is consistent with the requirements for differential astrometry of tens of micro-arc-seconds for certain science cases. While no show stoppers have been found, the work has resulted in several modifications to the NFIRAOS optical surface specifications and reference source design that will help improve the achievable astrometry precision even further.

  12. High Precision Temperature Control and Analysis of RF Deionized Cooling Water System

    CERN Document Server

    Tsai, Zong-Da; Chen June Rong; Liu, Chen-Yao

    2005-01-01

    Previously, the Taiwan Light Source (TLS) has proven the good beam quality mainly depends on the utility system stability. A serial of efforts were devoted to these studies. Further, a high precision temperature control of the RF deionized cooling water system will be achieved to meet the more critical stability requirement. The paper investigates the mixing mechanism through thermal and flow analysis and verifies the practical influences. A flow mixing mechanism and control philosophy is studied and processed to optimize temperature variation which has been reduced from ±0.1? to ±0.01?. Also, the improvement of correlation between RF performance and water cooling stability will be presented.

  13. Use of Terrestrial Laser Scanning Technology for Long Term High Precision Deformation Monitoring

    Science.gov (United States)

    Vezočnik, Rok; Ambrožič, Tomaž; Sterle, Oskar; Bilban, Gregor; Pfeifer, Norbert; Stopar, Bojan

    2009-01-01

    The paper presents a new methodology for high precision monitoring of deformations with a long term perspective using terrestrial laser scanning technology. In order to solve the problem of a stable reference system and to assure the high quality of possible position changes of point clouds, scanning is integrated with two complementary surveying techniques, i.e., high quality static GNSS positioning and precise tacheometry. The case study object where the proposed methodology was tested is a high pressure underground pipeline situated in an area which is geologically unstable. PMID:22303152

  14. New insights into the Aeolian Islands and other arc source compositions from high-precision olivine chemistry

    Science.gov (United States)

    Zamboni, Denis; Trela, Jarek; Gazel, Esteban; Sobolev, Alexander V.; Cannatelli, Claudia; Lucchi, Federico; Batanova, Valentina G.; De Vivo, Benedetto

    2017-02-01

    The Aeolian arc (Italy) is characterized by some of the strongest along-the-arc geochemical variations in the planet, making it an ideal location to study the effect of subducting components in modifying the mantle source of island arc melts. Here, we use high-precision element concentrations in primitive phenocrystic olivine from basalts along the arc to elucidate the effects of mantle source modification by the subduction process. Olivines from this arc have Ni concentrations and Fe/Mn ratios that show similarity to peridotite sources that melted to produce mid-ocean ridge basalts. Nevertheless, they also have systematically lower Ca concentrations and Fe/Mn ratios that broadly overlap with olivines from the available global arc array. These phenocrysts also do not show significant variations in Ca as a function of olivine forsterite content. The global data suggest that all olivines crystallizing from island-arc melts have suppressed Ca concentrations and Fe/Mn ratios, relative to olivines derived from melts at intraplate and mid-ocean ridge settings suggesting elevated H2O concentrations and higher oxidation state of the equilibrium melts. Based on olivine chemistry, we interpret a predominantly peridotite source (fluxed by subduction fluids) beneath the Aeolian Arc and also for other examples of arc-related lavas.

  15. Multifrequency high precise subTHz-THz-IR spectroscopy for exhaled breath research

    Science.gov (United States)

    Vaks, Vladimir L.; Domracheva, Elena G.; Pripolzin, Sergey I.; Chernyaeva, Mariya B.

    2016-09-01

    Nowadays the development of analytical spectroscopy with high performance, sensitivity and spectral resolution for exhaled breath research is attended. The method of two-frequency high precise THz spectroscopy and the method of high precise subTHz-THz-IR spectroscopy are presented. Development of a subTHz-THz-IR gas analyzer increases the number of gases that can be identified and the reliability of the detection by confirming the signature in both THz and MIR ranges. The testing measurements have testified this new direction of analytical spectroscopy to open widespread trends of its using for various problems of medicine and biology. First of all, there are laboratory investigations of the processes in exhaled breath and studying of their dynamics. Besides, the methods presented can be applied for detecting intermediate and short time living products of reactions in exhaled breath. The spectrometers have been employed for investigations of acetone, methanol and ethanol in the breath samples of healthy volunteers and diabetes patients. The results have demonstrated an increased concentration of acetone in breath of diabetes patients. The dynamic of changing the acetone concentration before and after taking the medicines is discovered. The potential markers of pre-cancer states and oncological diseases of gastrointestinal tract organs have been detected. The changes in the NO concentration in exhaled breath of cancer patients during radiotherapy as well as increase of the NH3 concentration at gastrointestinal diseases have been revealed. The preliminary investigations of biomarkers in three frequency ranges have demonstrated the advantages of the multifrequency high precise spectroscopy for noninvasive medical diagnostics.

  16. The neutron decay spectrometer aSPECT: Results of systematic studies

    Energy Technology Data Exchange (ETDEWEB)

    Borg, Michael; Beck, Marcus; Ayala Guardia, Fidel; Heil, Werner; Mu noz Horta, Raquel; Konrad, Gertrud; Ostrick, Beatrix [Institut fuer Physik, Universitaet Mainz (Germany); Baessler, Stefan [University of Virginia, Charlottesville, VA (United States); Glueck, Ferenc [IEKP, Universitaet Karlsruhe (Germany); Konorov, Igor [Physik-Department E18, TU, Muenchen (Germany); Simson, Martin; Soldner, Torsten; Zimmer, Oliver [Institut Laue-Langevin, Grenoble (France); Wirth, Hans-Friedrich [Fakultaet fuer Physik, LMU, Muenchen (Germany)

    2011-07-01

    The purpose of the retardation spectrometer aSPECT is to determine the antineutrino electron angular correlation coefficient a with high precision in free neutron decay. By measuring the recoil spectrum of the proton precisely, a determination of the ratio ({sub g}A)/(gV) of the weak coupling constants becomes possible as well as tests of the validity of the Standard Model. Of great interest are the search for scalar and tensor interactions and to test the unitarity of the CKM matrix. The present error of prior determinations of the coefficient a is ({delta}a)/(a){approx}5%. In a beam time performed at the research reactor of the ILL in Grenoble/ France in April/ May 2008 we achieved a statistical precision of (({delta}a)/(a)){sub stat.}<1.4%. The dominating systematical uncertainties have been identified and studied and are presented in this talk.

  17. Aspects of ultra-high-precision diamond machining of RSA 443 optical aluminium

    Science.gov (United States)

    Mkoko, Z.; Abou-El-Hossein, K.

    2015-08-01

    Optical aluminium alloys such as 6061-T6 are traditionally used in ultra-high precision manufacturing for making optical mirrors for aerospace and other applications. However, the optics industry has recently witnessed the development of more advanced optical aluminium grades that are capable of addressing some of the issues encountered when turning with single-point natural monocrystalline diamond cutters. The advent of rapidly solidified aluminium (RSA) grades has generally opened up new possibilities for ultra-high precision manufacturing of optical components. In this study, experiments were conducted with single-point diamond cutters on rapidly solidified aluminium RSA 443 material. The objective of this study is to observe the effects of depth of cut and feed rate at a fixed rotational speed on the tool wear rate and resulting surface roughness of diamond turned specimens. This is done to gain further understanding of the rate of wear on the diamond cutters versus the surface texture generated on the RSA 443 material. The diamond machining experiments yielded machined surfaces which are less reflective but with consistent surface roughness values. Cutting tools were observed for wear through scanning microscopy; relatively low wear pattern was evident on the diamond tool edge. The highest tool wear were obtained at higher depth of cut and increased feed rate.

  18. High-precision photometry by telescope defocussing. VII. The ultra-short period planet WASP-103

    CERN Document Server

    Southworth, John; Ciceri, S; Budaj, J; Dominik, M; Jaimes, R Figuera; Haugbolle, T; Jorgensen, U G; Popovas, A; Rabus, M; Rahvar, S; von Essen, C; Schmidt, R W; Wertz, O; Alsubai, K A; Bozza, V; Bramich, D M; Novati, S Calchi; D'Ago, G; Hinse, T C; Henning, Th; Hundertmark, M; Juncher, D; Korhonen, H; Skottfelt, J; Snodgrass, C; Starkey, D; Surdej, J

    2014-01-01

    We present 17 transit light curves of the ultra-short period planetary system WASP-103, a strong candidate for the detection of tidally-induced orbital decay. We use these to establish a high-precision reference epoch for transit timing studies. The time of the reference transit midpoint is now measured to an accuracy of 4.8s, versus 67.4s in the discovery paper, aiding future searches for orbital decay. With the help of published spectroscopic measurements and theoretical stellar models, we determine the physical properties of the system to high precision and present a detailed error budget for these calculations. The planet has a Roche lobe filling factor of 0.58, leading to a significant asphericity; we correct its measured mass and mean density for this phenomenon. A high-resolution Lucky Imaging observation shows no evidence for faint stars close enough to contaminate the point spread function of WASP-103. Our data were obtained in the Bessell $RI$ and the SDSS $griz$ passbands and yield a larger planet ...

  19. Towards high-precision mass measurements of neutron-rich fission products at TRIGA-SPEC

    Energy Technology Data Exchange (ETDEWEB)

    Nagy, Szilard [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany)

    2010-07-01

    TRIGA-TRAP, the only Penning trap mass spectrometer worldwide at a nuclear research reactor, is installed at TRIGA Mainz as part of the TRIGA-SPEC experiment. The scientific goal is to perform high-precision mass measurements on lanthanoids, actinoids and neutron-rich fission products produced by thermal neutron induced fission of a target inside the reactor. High-precision mass data are scarce in this region of the nuclear chart, and further experimental data are needed for nuclear structure studies of heavy elements, to test the predictive power of nuclear mass models, or as input to nucleosynthesis calculations of the astrophysical r-process. Ions of certain lanthanoids and most actinoids as well as carbon clusters for calibration purposes can be routinely produced by a newly developed non-resonant laser ablation ion source, allowing off-line mass measurements. Besides fundamental research, TRIGA-TRAP serves as a test bench for the development of efficient ion detection techniques, which will enable mass measurements ultimately on a single ion with a half-life of the order of one second. To this end, a unique combination of the commonly used time-of-flight technique and the non-destructive image current detection method is realized in an on-line mass spectrometer. The first mass measurement results are reported.

  20. The U-Th-Pb systematics of zircon from the Bishop Tuff: A case study in challenges to high-precision Pb/U geochronology at the millennial scale

    Science.gov (United States)

    Ickert, Ryan B.; Mundil, Roland; Magee, Charles W.; Mulcahy, Sean R.

    2015-11-01

    Dating zircon by U-Pb in the Pleistocene Bishop Tuff is challenging because the concentration of radiogenic Pb is low and the correction required for disequilibrium in the intermediate daughter products is large. The dates can be difficult to interpret, because their absolute precision is similar in magnitude to purported timescales of crystallization. Previous estimates of the duration of zircon crystallization span two orders of magnitude and appear to depend on the analytical approach. To reconcile the differing interpretations, we present new SIMS and ID-TIMS zircon Pb/U dates, including some crystals that are dated by both techniques. Both the SIMS and ID-TIMS dates have similar distributions as previous results. Normalized to a Th/Umelt = 2.81, SIMS spot dates from interior regions of sectioned grains range from 769 ± 31 ka to 845 ± 28 ka (2σ) and ID-TIMS dates have a range from 760 ± 7 ka to 793 ± 6 ka. Individual crystals dated by both methods have an average difference of 31 ka, with the SIMS dates being consistently older than the bulk crystal dates. This level of variability precludes the assignment of a geological significance to a mean (or weighted-mean) zircon date. A previous ID-TIMS investigation of single BT zircon that showed apparent statistically significant clustering of zircon ages was compromised by an incorrect treatment of the covariance structure of 230Th-corrected Pb/U data. We show approximate and exact methods for the correct treatment and demonstrate substantially more scatter in that data than previously recognized. Close scrutiny of available partition coefficient data show that they are not adequately precise for Bishop Tuff to <775 ka, which conflicts with some estimates of the 40Ar-39Ar sanidine age of eruption.

  1. Toward High-Precision Astrometry with WFPC2. I. Deriving an Accurate PSF

    CERN Document Server

    Anderson, J; Anderson, Jay; King, Ivan R.

    2000-01-01

    The first step toward doing high-precision astrometry is the measurement of individual stars in individual images, a step that is fraught with dangers when the images are undersampled. The key to avoiding systematic positional error in undersampled images is to determine an extremely accurate point-spread function (PSF). We apply the concept of the {\\it effective} PSF, and show that in images that consist of pixels it is the ePSF, rather than the often-used instrumental PSF, that embodies the information from which accurate star positions and magnitudes can be derived. We show how, in a rich star field, one can use the information from dithered exposures to derive an extremely accurate effective PSF by iterating between the PSF itself and the star positions that we measure with it. We also give a simple but effective procedure for representing spatial variations of the HST PSF. With such attention to the PSF, we find that we are able to measure the position of a single reasonably bright star in a single image...

  2. MEASURING HIGH-PRECISION ASTROMETRY WITH THE INFRARED ARRAY CAMERA ON THE SPITZER SPACE TELESCOPE

    Energy Technology Data Exchange (ETDEWEB)

    Esplin, T. L.; Luhman, K. L., E-mail: taran.esplin@psu.edu [Department of Astronomy and Astrophysics, The Pennsylvania State University, University Park, PA 16802 (United States)

    2016-01-15

    The Infrared Array Camera (IRAC) on the Spitzer Space Telescope currently offers the greatest potential for high-precision astrometry of faint mid-IR sources across arcminute-scale fields, which would be especially valuable for measuring parallaxes of cold brown dwarfs in the solar neighborhood and proper motions of obscured members of nearby star-forming regions. To more fully realize IRAC's astrometric capabilities, we have sought to minimize the largest sources of uncertainty in astrometry with its 3.6 and 4.5 μm bands. By comparing different routines that estimate stellar positions, we have found that Point Response Function (PRF) fitting with the Spitzer Science Center's Astronomical Point Source Extractor produces both the smallest systematic errors from varying intra-pixel sensitivity and the greatest precision in measurements of positions. In addition, self-calibration has been used to derive new 7th and 8th order distortion corrections for the 3.6 and 4.5 μm arrays of IRAC, respectively. These corrections are suitable for data throughout the mission of Spitzer when a time-dependent scale factor is applied to the corrections. To illustrate the astrometric accuracy that can be achieved by combining PRF fitting with our new distortion corrections, we have applied them to archival data for a nearby star-forming region, arriving at total astrometric errors of ∼20 and 70 mas at signal to noise ratios of 100 and 10, respectively.

  3. High-precision thermodynamic and critical properties from tensor renormalization-group flows.

    Science.gov (United States)

    Hinczewski, Michael; Berker, A Nihat

    2008-01-01

    The recently developed tensor renormalization-group (TRG) method provides a highly precise technique for deriving thermodynamic and critical properties of lattice Hamiltonians. The TRG is a local coarse-graining transformation, with the elements of the tensor at each lattice site playing the part of the interactions that undergo the renormalization-group flows. These tensor flows are directly related to the phase diagram structure of the infinite system, with each phase flowing to a distinct surface of fixed points. Fixed-point analysis and summation along the flows give the critical exponents, as well as thermodynamic functions along the entire temperature range. Thus, for the ferromagnetic triangular lattice Ising model, the free energy is calculated to better than 10(-5) along the entire temperature range. Unlike previous position-space renormalization-group methods, the truncation (of the tensor index range D) in this general method converges under straightforward and systematic improvements. Our best results are easily obtained with D=24, corresponding to 4624-dimensional renormalization-group flows.

  4. High-Precision Thermodynamic and Critical Properties from Tensor Renormalization-Group Flows

    Science.gov (United States)

    Hinczewski, Michael; Berker, A. Nihat

    2008-03-01

    The recently developed tensor renormalization-group (TRG) method [1] provides a highly precise technique for deriving thermodynamic and critical properties of lattice Hamiltonians. The TRG is a local coarse-graining transformation, with the elements of the tensor at each lattice site playing the part of the interactions that undergo the renormalization-group flows. These tensor flows are directly related [2] to the phase diagram structure of the infinite system, with each phase flowing to a distinct surface of fixed points. Fixed-point analysis and summation along the flows give the critical exponents, as well as thermodynamic functions along the entire temperature range. Thus, for the ferromagnetic triangular lattice Ising model, the free energy is calculated to better than 10-5 along the entire temperature range. Unlike previous position-space renormalization-group methods, the truncation (of the tensor index range D) in this general method converges under straightforward and systematic improvements. Our best results are easily obtained with D=24, corresponding to 4624-dimensional renormalization-group flows. [1] M. Levin and C.P. Nave, Phys. Rev. Lett. 99, 120601 (2007). [2] M. Hinczewski and A.N. Berker, arXiv:0709.2803v1 [cond-mat.stat-mech], Phys. Rev. E, in press.

  5. Measuring High-Precision Astrometry with the Infrared Array Camera on the Spitzer Space Telescope

    CERN Document Server

    Esplin, T L

    2015-01-01

    The Infrared Array Camera (IRAC) on the Spitzer Space Telescope currently offers the greatest potential for high-precision astrometry of faint mid-IR sources across arcminute-scale fields, which would be especially valuable for measuring parallaxes of cold brown dwarfs in the solar neighborhood and proper motions of obscured members of nearby star-forming regions. To more fully realize IRAC's astrometric capabilities, we have sought to minimize the largest sources of uncertainty in astrometry with its 3.6 and 4.5 $\\mu$m bands. By comparing different routines that estimate stellar positions, we have found that Point Response Function (PRF) fitting with the Spitzer Science Center's Astronomical Point Source Extractor produces both the smallest systematic errors from varying intra-pixel sensitivity and the greatest precision in measurements of positions. In addition, self-calibration has been used to derive new 7$^{\\rm th}$ and 8$^{\\rm th}$ order distortion corrections for the 3.6 and 4.5 $\\mu$m arrays of IRAC, ...

  6. Systematic hardness studies on lithium niobate crystals

    Indian Academy of Sciences (India)

    K G Subhadra; K Kishan Rao; D B Sirdeshmukh

    2000-04-01

    In view of discrepancies in the available information on the hardness of lithium niobate, a systematic study of the hardness has been carried out. Measurements have been made on two pure lithium niobate crystals with different growth origins, and a Fe-doped sample. The problem of load variation of hardness is examined in detail. The true hardness of LiNbO3 is found to be 630 ± 30 kg/mm2. The Fe-doped crystal has a larger hardness of 750 ± 50 kg/mm2.

  7. Upgrade of the SPIRAL identification station for high-precision measurements of nuclear β decay

    Energy Technology Data Exchange (ETDEWEB)

    Grinyer, G.F., E-mail: grinyer@ganil.fr [Grand Accélérateur National d' Ions Lourds (GANIL), CEA/DSM-CNRS/IN2P3, Bvd Henri Becquerel, 14076 Caen (France); Thomas, J.C. [Grand Accélérateur National d' Ions Lourds (GANIL), CEA/DSM-CNRS/IN2P3, Bvd Henri Becquerel, 14076 Caen (France); Blank, B. [Centre d’Études Nucléaires de Bordeaux Gradignan, Université Bordeaux 1, UMR 5797, CNRS/IN2P3, Chemin de Solarium, BP 120, 33175 Gradignan (France); Bouzomita, H. [Grand Accélérateur National d' Ions Lourds (GANIL), CEA/DSM-CNRS/IN2P3, Bvd Henri Becquerel, 14076 Caen (France); Austin, R.A.E. [Astronomy and Physics Department, Saint Mary' s University, Halifax, Nova Scotia, Canada B3H 3C3 (Canada); Ball, G.C. [TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia, Canada V6T 2A3 (Canada); Bucaille, F.; Delahaye, P. [Grand Accélérateur National d' Ions Lourds (GANIL), CEA/DSM-CNRS/IN2P3, Bvd Henri Becquerel, 14076 Caen (France); Finlay, P. [Instituut voor Kern- en Stralingsfysica, K.U. Leuven, Celestijnenlaan 200D, B-3001 Leuven (Belgium); Frémont, G. [Grand Accélérateur National d' Ions Lourds (GANIL), CEA/DSM-CNRS/IN2P3, Bvd Henri Becquerel, 14076 Caen (France); Gibelin, J. [LPC-Caen, ENSICAEN, Université de Caen, CNRS/IN2P3, Caen (France); Giovinazzo, J. [Centre d’Études Nucléaires de Bordeaux Gradignan, Université Bordeaux 1, UMR 5797, CNRS/IN2P3, Chemin de Solarium, BP 120, 33175 Gradignan (France); and others

    2014-03-21

    The low-energy identification station at SPIRAL (Système de Production d'Ions Radioactifs Accélérés en Ligne) has been upgraded for studying the β decays of short-lived radioactive isotopes and to perform high-precision half-life and branching-ratio measurements for superallowed Fermi and isospin T=1/2 mirror β decays. These new capabilities, combined with an existing Paul trap setup for measurements of β–ν angular-correlation coefficients, provide a powerful facility for investigating fundamental properties of the electroweak interaction through nuclear β decays. A detailed description of the design study, construction, and first results obtained from an in-beam commissioning experiment on the β{sup +} decays {sup 14} O and {sup 17}F are presented.

  8. Research on a High-Precision Delay Circuit in Data Acquisition Systems

    Institute of Scientific and Technical Information of China (English)

    MA Kai; SU Hong-qi; YANG Gong-xun

    2006-01-01

    This paper presents a novel precision delay circuit design for high-speed data acquisition systems. Many studies have suggested that various advanced electronic measurement apparatuses require that the delay circuit should have a high precision and a short delay interval. Practically, however, such measurement apparatuses are low in precision and long in delay interval at present. The structure and function of a data acquisition system is introduced first; then the principle of ramp-based precision delay circuits and the digitally programmable delay generator is studied and the precision delay circuit is designed. The authors also demonstrated 8-bit programmable delay circuits with a timing precision of 10 ps. Therefore the programmable precision delay circuit here presented has a higher precision, shorter interval and more detectable function than any other precision delay circuit.

  9. Development of a facility for high-precision irradiation of cells with carbon ions

    Energy Technology Data Exchange (ETDEWEB)

    Goethem, Marc-Jan van; Niemantsverdriet, Maarten; Brandenburg, Sytze; Langendijk, Johannes A.; Coppes, Robert P.; Luijk, Peter van [Department of Cell Biology, Section of Radiation and Stress Cell Biology, University Medical Center Groningen, University of Groningen, A. Deusinglaan 1, 9713AV Groningen (Netherlands); Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700RB Groningen (Netherlands); Kernfysisch Versneller Instituut, University of Groningen, Zernikelaan 25, 9747AA Groningen (Netherlands); Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700RB Groningen (Netherlands); Department of Cell Biology, Section of Radiation and Stress Cell Biology, University Medical Center Groningen, University of Groningen, A. Deusinglaan 1, 9713AV Groningen (Netherlands); Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700RB Groningen (Netherlands)

    2011-01-15

    Purpose: Compared to photons, using particle radiation in radiotherapy reduces the dose and irradiated volume of normal tissues, potentially reducing side effects. The biological effect of dose deposited by particles such as carbon ions, however, differs from that of dose deposited by photons. The inaccuracy in models to estimate the biological effects of particle radiation remains the most important source of uncertainties in particle therapy. Improving this requires high-precision studies on biological effects of particle radiation. Therefore, the authors aimed to develop a facility for reproducible and high-precision carbon-ion irradiation of cells in culture. The combined dose nonuniformity in the lateral and longitudinal direction should not exceed {+-}1.5%. Dose to the cells from particles than other carbon ions should not exceed 5%. Methods: A uniform lateral dose distribution was realized using a single scatter foil and quadrupole magnets. A modulator wheel was used to create a uniform longitudinal dose distribution. The choice of beam energy and the optimal design of these components was determined using GEANT4 and SRIM Monte Carlo simulations. Verification of the uniformity of the dose distribution was performed using a scintillating screen (lateral) and a water phantom (longitudinal). The reproducibility of dose delivery between experiments was assessed by repeated measurements of the spatial dose distribution. Moreover, the reproducibility of dose-response measurements was tested by measuring the survival of irradiated HEK293 cells in three independent experiments. Results: The relative contribution of dose from nuclear reaction fragments to the sample was found to be <5% when using 90 MeV/u carbon ions. This energy still allows accurate dosimetry conforming to the IAEA Report TRS-398, facilitating comparison to dose-effect data obtained with other radiation qualities. A 1.3 mm long spread-out Bragg peak with a diameter of 30 mm was created, allowing

  10. High precision and stable structures for particle detectors

    CERN Document Server

    Da Mota-Silva, S; Hauviller, Claude

    1999-01-01

    We are studying structures in CFRP with bonded piezoelectric sensors and actuators, able to monitor and compensate the vibrations affecting the performance of these systems. In this paper a detailed description of the simulation model is presented and the results compared with the experimental measurements. The transient response of a plate structure under vibrations with and without feedback control are shown. (7 refs).

  11. CUSB-II: A high precision electromagnetic spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Schamberger, R.D.; Heintz, U.; Lee-Franzini, J.; Lovelock, D.M.J.; Narain, M.; Willins, J.; Yanagisawa, C. (SUNY, Stony Brook, NY (United States)); Tuts, P.M.; Franzini, P.; Kanekal, S.; Wu, Q.W. (Columbia Univ., New York, NY (United States))

    1991-11-15

    The design, construction and performance of a very compact precision electromagnetic spectrometer is described. The CUSB-II detectors has been used to study {gamma} spectroscopy, search for exotic particles and measure properties of the B and B{sup *} mesons at the Cornell Electron Storage Ring. (orig.).

  12. Vibratory response modeling and verification of a high precision optical positioning system.

    Energy Technology Data Exchange (ETDEWEB)

    Barraza, J.; Kuzay, T.; Royston, T. J.; Shu, D.

    1999-06-18

    A generic vibratory-response modeling program has been developed as a tool for designing high-precision optical positioning systems. Based on multibody dynamics theory, the system is modeled as rigid-body structures connected by linear elastic elements, such as complex actuators and bearings. The full dynamic properties of each element are determined experimentally or theoretically, then integrated into the program as inertial and stiffness matrices. Utilizing this program, the theoretical and experimental verification of the vibratory behavior of a double-multilayer monochromator support and positioning system is presented. Results of parametric design studies that investigate the influence of support floor dynamics and highlight important design issues are also presented. Overall, good matches between theory and experiment demonstrate the effectiveness of the program as a dynamic modeling tool.

  13. Devices for high precision x-ray beam intensity monitoring on BSRF

    CERN Document Server

    Hua-Peng, LI; Zhao, Yi-Dong; Zheng, Lei; Liu, Shu-Hu; Zhao, Xiao-Liang; Zhao, Ya-Shuai

    2016-01-01

    Synchrotron radiation with the characteristic of high brilliance, high level of polarization, high collimation, low emittance and wide tunability in energy has been used as a standard source in metrology(1, 2). For a decade, lots of calibration work have been done on 4B7A in Beijing Synchrotron Radiation Facility (BSRF) (3, 4). For the calibration process, a high-precision online monitor is indispensable. To control the uncertainty under 0.1%, we studied different sizes parallel ion chambers with rare-gas and used different collecting methods to monitor the x-ray intensity of the beamline. Two methods to collect the signal of the ion chambers: reading the current directly with electrometer or signal amplification to collect the counts were compared.

  14. First-order reversal curves acquired by a high precision ac induction magnetometer.

    Science.gov (United States)

    Béron, F; Soares, G; Pirota, K R

    2011-06-01

    We present a setup allowing to characterize the local irreversible behavior of soft magnetic samples. It is achieved by modifying a conventional ac induction magnetometer in order to measure first-order reversal curves (FORCs), a magnetostatic characterization technique. The required modifications were performed on a home-made setup allowing high precision measurement, with sensibility less than 0.005 Oe for the applied field and 10(-6) emu for the magnetization. The main crucial point for the FORCs accuracy is the constancy of the applied field sweep rate, because of the magnetic viscosity. Therefore, instead of the common way to work at constant frequency, each FORC is acquired at a slightly different frequency, in order to keep the field variation constant in time. The obtained results exhibit the consequences of magnetic viscosity, thus opening up the path of studying this phenomenon for soft magnetic materials.

  15. High-precision photometry by telescope defocussing. VI. WASP-24, WASP-25 and WASP-26

    CERN Document Server

    Southworth, John; Burgdorf, M; Novati, S Calchi; Dominik, M; Galianni, P; Gerner, T; Giannini, E; Gu, S -H; Hundertmark, M; Jorgensen, U G; Juncher, D; Kerins, E; Mancini, L; Rabus, M; Ricci, D; Schaefer, S; Skottfelt, J; Tregloan-Reed, J; Wang, X -B; Wertz, O; Alsubai, K A; Andersen, J M; Bozza, V; Bramich, D M; Browne, P; Ciceri, S; D'Ago, G; Damerdji, Y; Diehl, C; Dodds, P; Elyiv, A; Fang, X -S; Finet, F; Jaimes, R Figuera; Hardis, S; Harpsoe, K; Jessen-Hansen, J; Kains, N; Kjeldsen, H; Korhonen, H; Liebig, C; Lund, M N; Lundkvist, M; Mathiasen, M; Penny, M T; Popovas, A; Proft, S; Rahvar, S; Sahu, K; Scarpetta, G; Schmidt, R W; Schoenebeck, F; Snodgrass, C; Street, R A; Surdej, J; Tsapras, Y; Vilela, C

    2014-01-01

    We present time-series photometric observations of thirteen transits in the planetary systems WASP-24, WASP-25 and WASP-26. All three systems have orbital obliquity measurements, WASP-24 and WASP-26 have been observed with Spitzer, and WASP-25 was previously comparatively neglected. Our light curves were obtained using the telescope-defocussing method and have scatters of 0.5 to 1.2 mmag relative to their best-fitting geometric models. We used these data to measure the physical properties and orbital ephemerides of the systems to high precision, finding that our improved measurements are in good agreement with previous studies. High-resolution Lucky Imaging observations of all three targets show no evidence for faint stars close enough to contaminate our photometry. We confirm the eclipsing nature of the star closest to WASP-24 and present the detection of a detached eclipsing binary within 4.25 arcmin of WASP-26.

  16. Drag-Free Motion Control of Satellite for High-Precision Gravity Field Mapping

    DEFF Research Database (Denmark)

    2002-01-01

    , sensors, actuators and environmental disturbances to the required micro-Newton accuracy. A control system is designed to compensate the non-gravitational disturbances on the satellite in three axes using an H∞-design. Performance is validated against mission requirements. Keywords: Spacecraft Attitude......High precision mapping of the geoid and the Earth's gravity field are of importance to a wide range of ongoing studies in areas like ocean circulation, solid Earth physics and ice sheet dynamics. Using a satellite in orbit around the Earth gives the opportunity to map the Earth's gravity field in 3...... dimensions with much better accuracy and spatial resolution than ever accomplished. To reach the desired quality of measurements, the satellite must fly in a low Earth orbit where disturbances from atmospheric drag and the Earth's magnetic field will perturb the satellite's motion. These effects...

  17. Effect of inhomogeneities on high precision measurements of cosmological distances

    CERN Document Server

    Peel, Austin; Ishak, Mustapha

    2014-01-01

    We study exact relativistic effects of inhomogeneities on distance measures, focusing on the distance modulus, in a Swiss-cheese model of the universe with $\\Lambda$CDM background dynamics, and where the `holes' are non-symmetric structures described by the Szekeres metric. The Szekeres exact solution of Einstein's equations, which is inhomogeneous and anisotropic, allows us to capture potentially relevant effects on light propagation due to nontrivial evolution of structures. Unlike Swiss-cheese model studies with spherically symmetric holes, we find a net shift in the distance modulus $\\mu$ to distant sources even when we average over many lines of sight with randomized hole orientations and impact parameters. The light also need not propagate strictly through underdense regions to result in an overall bias, which is an accumulated effect associated with the evolution of the anisotropic holes. We find the average shift $\\langle\\Delta\\mu\\rangle$ relative to a pure $\\Lambda$CDM model to increase with redshift...

  18. Derivative properties from high-precision equations of state.

    Science.gov (United States)

    Haghbakhsh, Reza; Konttorp, Morten; Raeissi, Sona; Peters, Cor J; O'Connell, John P

    2014-12-11

    In this study, the behavior of derivative properties estimated by equations of state, including isochoric heat capacity, isobaric heat capacity, speed of sound, and the Joule-Thomson coefficient for pure compounds and a mixture, has been investigated. The Schmidt-Wagner and Jacobsen-Stewart equations of state were used for predictions of derivative properties of 10 different pure compounds from various nonpolar hydrocarbons, nonpolar cyclic hydrocarbons, polar compounds, and refrigerants. The estimations were compared to experimental data. To evaluate the behavior of mixtures, the extended corresponding states principle (ECS) was studied. Analytical relationships were derived for isochoric heat capacity, isobaric heat capacity, the Joule-Thomson coefficient, and the speed of sound. The ECS calculations were compared to the reference surface data of methane + ethane. The ECS principle was found to generate data of high quality.

  19. High precision Symplectic Integrators for the Solar System

    CERN Document Server

    Farrés, Ariadna; Blanes, Sergio; Casas, Fernando; Makazaga, Joseba; Murua, Ander

    2012-01-01

    Using a Newtonian model of the Solar System with all 8 planets, we perform extensive tests on various symplectic integrators of high orders, searching for the best splitting scheme for long term studies in the Solar System. These comparisons are made in Jacobi and Heliocentric coordinates and the implementation of the algorithms is fully detailed for practical use. We conclude that high order integrators should be privileged, with a preference for the new $(10,6,4)$ method of (Blanes et al., 2012)

  20. Impact of Planetary Gravitation on High Precision Neutral Atom Measurements

    Science.gov (United States)

    Kucharek, H.; Galli, A.; Wurz, P.; Moebius, E.; Lee, M. A.; Park, J.; Fuselier, S. A.; Bzowski, M.; Schwadron, N.; McComas, D. J.

    2015-12-01

    Measurements of energetic neutral atoms (ENAs) have been extremely successful in providing very important information on physical processes inside and outside our heliosphere. For instance, recent IBEX observations provided new insights into the local interstellar environment and improved measurements of the interstellar He temperature, velocity, and direction of the interstellar flow vector. Since particle collisions are rare and radiation pressure is negligible for these neutrals, gravitational forces mainly determine the trajectories of neutral He atoms. Depending on the distance of an ENA to the source of a gravitational field and its relative speed and direction this can result in a significant deflection and acceleration. In this presentation we study the impact of the gravitational effects of the Earth, Moon, and Jupiter on ENA measurements performed in Earth orbit. We show that planetary gravitational effects do not significantly affect the interstellar neutral gas parameters obtained from IBEX observations. We further study the possibility whether the He focusing cone of the Sun or Jupiter could be measured by IBEX, and whether these cones could be used as an independent measure of the interstellar He temperature. These topics are of particular importance for future missions such as IMAP, which will provide ENA images for a broader energy range and with better sensitivity and resolution.

  1. High precision Hugoniot measurements of D2 near maximum compression

    Science.gov (United States)

    Benage, John; Knudson, Marcus; Desjarlais, Michael

    2015-11-01

    The Hugoniot response of liquid deuterium has been widely studied due to its general importance and to the significant discrepancy in the inferred shock response obtained from early experiments. With improvements in dynamic compression platforms and experimental standards these results have converged and show general agreement with several equation of state (EOS) models, including quantum molecular dynamics (QMD) calculations within the Generalized Gradient Approximation (GGA). This approach to modeling the EOS has also proven quite successful for other materials and is rapidly becoming a standard approach. However, small differences remain among predictions obtained using different local and semi-local density functionals; these small differences show up in the deuterium Hugoniot at ~ 30-40 GPa near the region of maximum compression. Here we present experimental results focusing on that region of the Hugoniot and take advantage of advancements in the platform and standards, resulting in data with significantly higher precision than that obtained in previous studies. These new data may prove to distinguish between the subtle differences predicted by the various density functionals. Results of these experiments will be presented along with comparison to various QMD calculations. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin company, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  2. Intrinsic Instrumental Polarization and High-Precision Pulsar Timing

    CERN Document Server

    Foster, Griffin; Paulin, Remi; Carozzi, Tobia; Johnston, Simon; van Straten, Willem

    2015-01-01

    Radio telescopes are used to accurately measure the time of arrival (ToA) of radio pulses in pulsar timing experiments that target mostly millisecond pulsars (MSPs) due to their high rotational stability. This allows for detailed study of MSPs and forms the basis of experiments to detect gravitational waves. Apart from intrinsic and propagation effects, such as pulse-to-pulse jitter and dispersion variations in the interstellar medium, timing precision is limited in part by the following: polarization purity of the telescope's orthogonally polarized receptors, the signal-to-noise ratio (S/N) of the pulsar profile, and the polarization fidelity of the system. Using simulations, we present how fundamental limitations in recovering the true polarization reduce the precision of ToA measurements. Any real system will respond differently to each source observed depending on the unique pulsar polarization profile. Using the profiles of known MSPs we quantify the limits of observing system specifications that yield s...

  3. High-Precision Measurements of Brightness Variation of Nereid

    CERN Document Server

    Terai, Tsuyoshi

    2012-01-01

    Nereid, a satellite of Neptune, has a highly eccentric prograde orbit with a semi-major axis larger than 200 Neptune radius and is classified as an irregular satellite. Although the capture origin of irregular satellites has been widely accepted, several previous studies suggest that Nereid was formed in the circumplanetary disk of Neptune and was ejected outward to the present location by Triton. Our time-series photometric observations confirm that the spin is stable and non-chaotic with a period of 11.5 hr as indicated by Grav et al. (2003). The optical colors of Nereid are indistinguishable from those of trans-Neptunian objects and Centaurs, especially those with neutral colors. We also find the consistency of Nereid's rotation with the size-rotation distribution of small outer bodies. It is more likely that Nereid originates in an immigrant body captured from a heliocentric orbit which was 4-5 AU away from Neptune's orbit.

  4. High precision and stable structures for particle detectors

    CERN Document Server

    Da Mota Silva, S; Hauviller, Claude

    1999-01-01

    The central detectors used in High Energy Physics Experiments require the use of light and stable structures capable of supporting delicate and precise radiation detection elements. These structures need to be highly stable under environmental conditions where external vibrations, high radiation levels, temperature and humidity gradients should be taken into account. Their main design drivers are high dimension and dynamic stability, high stiffness to mass ratio and large radiation length. For most applications, these constraints lead us to choose Carbon Fiber Reinforced Plastics ( CFRP) as structural element. The construction of light and stable structures with CFRP for these applications can be achieved by careful design engineering and further confirmation at the prototyping phase. However, the experimental environment can influence their characteristics and behavior. In this case, theuse of adaptive structures could become a solution for this problem. We are studying structures in CFRP with bonded piezoel...

  5. High Precision Cosmology with the Cosmic Background Radiation

    Science.gov (United States)

    Farhang, Marzieh

    In this thesis we investigate the two cosmic epochs of inflation and recombination, through their imprints on the temperature and polarization anisotropies of the cosmic microwave background radiation. To probe the early universe we develop a map-based maximum-likelihood estimator to measure the amplitude of inflation-induced gravity waves, parametrized by r, from the cosmic microwave background (CMB) polarization maps. Being optimal by construction, the estimator avoids E-B mixing, a possible source of contamination in the tiny B-mode detection, the target of many current and near future CMB experiments. We explore the leakage from the E- to the B-mode of polarization by using this estimator to study the linear response of the B-mode signal at different scales to variations in the E- mode power. Similarly, for various observational cases, we probe the dependence of r measurement on the signal from different scales of E and B polarization. The estimator is used to make forecasts for Spider-like and Planck-like experimental specifications and to investigate the sky-coverage optimization of the Spider-like case. We compare the forecast errors on r to the results from a similar multipole-based estimator which, by ignoring the mode-mixing, sets a lower limit on the achievable error on r. We find that an experiment with Spider-like specifications with fsky ˜ 0:02--0:2 could place a 2sigma r ≈ 0:014 bound (˜ 95% CL), which rises to 0:02 with an ℓ-dependent foreground residual left over from an assumed efficient component separation. For the Planck-like survey, a Galaxy-masked ( fsky = 0:75) sky would give 2sigmar ≈ 0:015, rising to ≈ 0:05 with the foreground residuals. We also use a novel information-based framework to compare how different generations of CMB experiments reveal information about the early universe, through their measurements of r. We also probe the epoch of recombination by investigating possible fluctuations in the free electron fraction Xe

  6. Systematic study of the uncertainties in fitting the cosmic positron data by AMS-02

    CERN Document Server

    Yuan, Qiang

    2015-01-01

    The launch of AMS-02 opens a new era for cosmic ray physics with unprecedented precision of data, which are comparable with the laboratory measurements. The high precision data allow a quantitative study on the cosmic ray physics and give strict constraints on the nature of cosmic ray sources. However, the intrinsic errors from theoretical models to interpret the data become dominant over the errors in data. In the present work we try to give a systematic study on these uncertainties to explain, as an explicit example, the first AMS-02 positron fraction data, which shows the cosmic ray positron/electron excesses together with the PAMELA, Fermi-LAT measurements. The excesses can be attributed to contributions from new positron/electron sources, like pulsars or dark matter annihilation. The precise data give strict constraints on properties of the new sources. We study the systematic uncertainties from cosmic ray propagation, solar modulation, the $pp$ interaction models, the nuclei injection spectrum and so on...

  7. Effect of inhomogeneities on high precision measurements of cosmological distances

    Science.gov (United States)

    Peel, Austin; Troxel, M. A.; Ishak, Mustapha

    2014-12-01

    We study effects of inhomogeneities on distance measures in an exact relativistic Swiss-cheese model of the Universe, focusing on the distance modulus. The model has Λ CDM background dynamics, and the "holes" are nonsymmetric structures described by the Szekeres metric. The Szekeres exact solution of Einstein's equations, which is inhomogeneous and anisotropic, allows us to capture potentially relevant effects on light propagation due to nontrivial evolution of structures in an exact framework. Light beams traversing a single Szekeres structure in different ways can experience either magnification or demagnification, depending on the particular path. Consistent with expectations, we find a shift in the distance modulus μ to distant sources due to demagnification when the light beam travels primarily through the void regions of our model. Conversely, beams are magnified when they propagate mainly through the overdense regions of the structures, and we explore a small additional effect due to time evolution of the structures. We then study the probability distributions of Δ μ =μΛ CDM-μSC for sources at different redshifts in various Swiss-cheese constructions, where the light beams travel through a large number of randomly oriented Szekeres holes with random impact parameters. We find for Δ μ the dispersions 0.004 ≤σΔ μ≤0.008 mag for sources with redshifts 1.0 ≤z ≤1.5 , which are smaller than the intrinsic dispersion of, for example, magnitudes of type Ia supernovae. The shapes of the distributions we obtain for our Swiss-cheese constructions are peculiar in the sense that they are not consistently skewed toward the demagnification side, as they are in analyses of lensing in cosmological simulations. Depending on the source redshift, the distributions for our models can be skewed to either the demagnification or the magnification side, reflecting a limitation of these constructions. This could be the result of requiring the continuity of Einstein

  8. High precision stress measurements in semiconductor structures by Raman microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Uhlig, Benjamin

    2009-07-01

    Stress in silicon structures plays an essential role in modern semiconductor technology. This stress has to be measured and due to the ongoing miniaturization in today's semiconductor industry, the measuring method has to meet certain requirements. The present thesis deals with the question how Raman spectroscopy can be used to measure the state of stress in semiconductor structures. In the first chapter the relation between Raman peakshift and stress in the material is explained. It is shown that detailed stress maps with a spatial resolution close to the diffraction limit can be obtained in structured semiconductor samples. Furthermore a novel procedure, the so called Stokes-AntiStokes-Difference method is introduced. With this method, topography, tool or drift effects can be distinguished from stress related influences in the sample. In the next chapter Tip-enhanced Raman Scattering (TERS) and its application for an improvement in lateral resolution is discussed. For this, a study is presented, which shows the influence of metal particles on the intensity and localization of the Raman signal. A method to attach metal particles to scannable tips is successfully applied. First TERS scans are shown and their impact on and challenges for high resolution stress measurements on semiconductor structures is explained. (orig.)

  9. Unraveling high precision stereocontrol in a triple cascade organocatalytic reaction.

    Science.gov (United States)

    Shinisha, C B; Sunoj, Raghavan B

    2008-11-07

    The mechanism and stereoselectivity in an organocatalyzed triple cascade reaction between an aldehyde, electron deficient olefin and an alpha,beta-unsaturated aldehyde are investigated for the first time using density functional theory. The factors responsible for high levels of observed stereoselectivity (Enders et al., Nature, 2006, 441, 861) towards the generation of cyclohexene carbaldehyde with four contiguous stereocentres are unravelled. The triple cascade reaction, comprising a Michael, Michael and aldol sequence as the key elementary reactions, is studied by identifying the corresponding transition states for the stereoselective C-C bond-formation. In the first Michael addition step between the enamine (derived from the chiral catalyst and propanal) and nitrostyrene, energetically the most preferred mode of addition is found to be between the si-face of (E)-anti-enamine on the si-face of nitrostyrene. The addition of the si-face of the nitroalkane anion on the re-face of the iminium ion (formed between the enal and the catalyst) is the lowest energy pathway for the second Michael addition step. The high level of asymmetric induction is rationalized with the help of relative activation barriers associated with the competitive diastereomeric pathways. Interesting weak interactions, along with the steric effects offered by the bulky alpha-substituent on the pyrrolidine ring, are identified as critical to the stereoselectivity in this triple cascade reaction. The predicted stereoselectivities using computed energetics are found to be in perfect harmony with the experimental stereoselectivities.

  10. High-Precision Gravity and GPS Monitoring of The Geysers Geothermal System

    Science.gov (United States)

    Gettings, P.; Allis, R.; Harris, R. N.; Chapman, D. S.

    2001-12-01

    Concurrent gravity and GPS monitoring of geothermal systems can provide important information on subsurface mass changes induced by production. High-precision GPS measurements provide direct, low-cost, surface deformation data, which are useful for tracking potential problems in reservoir engineering (e.g. well-bore shearing). Elevation changes combined with high-precision gravity data produce an accurate picture of total mass change in the system. Repeated observations over time track the spatial and temporal patterns of change. We present results of the first year of a coupled gravity and GPS study located in The Geysers geothermal system, northern California, USA. During 3 field campaigns, we occupied 60 stations on the production field to provide a baseline for future mass change, and to track the seasonal and inter-annual variability. Comparison of data between 1977 and 2000 show an average annual subsidence-corrected gravity change rate of ~-26 μ Gal/year, for a total change of ~-600 μ Gal. Existing GPS measurements from 1996 show subsidence up to 0.8 m [Mossop et al, 1997], which we have extrapolated by 20% to correct more recent gravity data. Spatial patterns in the gravity change follow the production history, and simple 1-D modeling of the gravity effect produces good agreement. A larger network (160 stations), covering the production field and surrounding areas, was installed in September 2001 to provide the baseline for future mass change associated with an enhanced injection project at the reservoir. Mossop, A., Murray, M., Owen, S., and Segall, P. 1997. Subsidence at The Geysers geothermal field: results and simple models. Proc. 22nd Workshop on Geothermal Reservoir Engineering, Stanford University, 377-382.

  11. HIGH-PRECISION DETERMINATION OF THE ANGULAR POSITION FOR POINT LIGHT SOURCE WITH CCD-ARRAYS

    Directory of Open Access Journals (Sweden)

    Y. G. Lebedko

    2015-05-01

    Full Text Available Subject of study. A method of angular position measuring for point light source in the system with CCD arrays is proposed by converting of angle – time – code in low light conditions and at high signal / noise ratio. Assessment of the method potential accuracy is given. It is determined by instrumental irremovable random errors of measurement in terms of optimal processing of incoming information with a single reading it with CCD – arrays. Method. This work introduces an optoelectronic system circuit with CCD arrays with stretched sensing elements and a point of reference for angular position measuring. In this case the arrays have images projections of both the reference point source and the target point source, which angular position is measured with high precision. From the CCD array output the signals arrive at an optimal (or apt linear filter, and then to the signal peak position detection circuit. The scheme provides minimum error due to the influence of noise. Pulse edges, corresponding to the signals maximum, make a time interval filled with high-frequency counting pulses. The number of pulses in this interval will correspond to the measured angular position of the target point source. Main results. Analysis of random errors has been carried out in terms of statistical decision theory. Analysis takes into account the spectral function of the signals defined by transfer functions of the optical system and a CCD array as an image analyzer. Research of measurement accuracy is carried out depending on the clock frequency of reading information from CCD arrays for different values of signal-to-noise ratio. It has been shown that even with a single readout with CCD array by the proposed opto-electronic circuit measuring error does not exceed 0.01 of the sensing element size. Practical significance. The results are usable in high-precision measuring opto-electronic systems of star sensors for determining the angular position of the low

  12. Evaluation of High-Precision Sensors in Structural Monitoring

    Directory of Open Access Journals (Sweden)

    Bihter Erol

    2010-12-01

    Full Text Available One of the most intricate branches of metrology involves the monitoring of displacements and deformations of natural and anthropogenic structures under environmental forces, such as tidal or tectonic phenomena, or ground water level changes. Technological progress has changed the measurement process, and steadily increasing accuracy requirements have led to the continued development of new measuring instruments. The adoption of an appropriate measurement strategy, with proper instruments suited for the characteristics of the observed structure and its environmental conditions, is of high priority in the planning of deformation monitoring processes. This paper describes the use of precise digital inclination sensors in continuous monitoring of structural deformations. The topic is treated from two viewpoints: (i evaluation of the performance of inclination sensors by comparing them to static and continuous GPS observations in deformation monitoring and (ii providing a strategy for analyzing the structural deformations. The movements of two case study objects, a tall building and a geodetic monument in Istanbul, were separately monitored using dual-axes micro-radian precision inclination sensors (inclinometers and GPS. The time series of continuous deformation observations were analyzed using the Least Squares Spectral Analysis Technique (LSSA. Overall, the inclinometers showed good performance for continuous monitoring of structural displacements, even at the sub-millimeter level. Static GPS observations remained insufficient for resolving the deformations to the sub-centimeter level due to the errors that affect GPS signals. With the accuracy advantage of inclination sensors, their use with GPS provides more detailed investigation of deformation phenomena. Using inclinometers and GPS is helpful to be able to identify the components of structural responses to the natural forces as static, quasi-static, or resonant.

  13. Single Crystal Piezomotor for Large Stroke, High Precision and Cryogenic Actuations Project

    Data.gov (United States)

    National Aeronautics and Space Administration — TRS Technologies proposes a novel single crystal piezomotor for large stroke, high precision, and cryogenic actuations with capability of position set-hold with...

  14. The High Precision Vibration Signal Data Acquisition System Based on the STM32

    National Research Council Canada - National Science Library

    Zhu Hui-Ling; Zhu Xin-Yin

    2014-01-01

    ... changes in cable resistance. Therefore, this paper proposed a high precision vibration signal acquisition with storage function based on STM32 microcontroller in order to promote safety in engineering construction...

  15. High-precision atom localization via controllable spontaneous emission in a cycle-configuration atomic system

    National Research Council Canada - National Science Library

    Ding, Chunling; Li, Jiahua; Yu, Rong; Hao, Xiangying; Wu, Ying

    2012-01-01

    .... Therefore, by detecting the emitted photon one could obtain the position information available, and then we demonstrate high-precision and high-resolution 2D atom localization induced by the quantum...

  16. High Precision and High Yield Fabrication of Dense Nanoparticle Arrays onto DNA Origami at Statistically Independent Binding Sites †

    OpenAIRE

    Takabayashi, Sadao; Klein, William P.; Onodera, Craig; Rapp, Blake; Flores-Estrada, Juan; Lindau, Elias; Snowball, Lejmarc; Sam, Joseph Tyler; Padilla, Jennifer E.; Lee, Jeunghoon; Knowlton, William B.; Graugnard, Elton; Yurke, Bernard; Kuang, Wan; Hughes, William L.

    2014-01-01

    High precision, high yield, and high density self-assembly of nanoparticles into arrays is essential for nanophotonics. Spatial deviations as small as a few nanometers can alter the properties of near-field coupled optical nanostructures. Several studies have reported assemblies of few nanoparticle structures with controlled spacing using DNA nanostructures with variable yield. Here, we report multi-tether design strategies and attachment yields for homo- and hetero-nanoparticle arrays templa...

  17. Laser cooling and trapping of atomic strontium for ultracold atom physics, high-precision spectroscopy and quantum sensors

    OpenAIRE

    Sorrentino, F.; Ferrari, G.; Poli, N.; Drullinger, R. E.; G. M. Tino

    2006-01-01

    This review describes the production of atomic strontium samples at ultra-low temperature and at high phase-space density, and their possible use for physical studies and applications. We describe the process of loading a magneto-optical trap from an atomic beam and preparing the sample for high precision measurements. Particular emphasis is given to the applications of ultracold Sr samples, spanning from optical frequency metrology to force sensing at micrometer scale.

  18. On the Mitigation of Solar Index Variability for High Precision Orbit Determination in Low Earth Orbit

    Science.gov (United States)

    2016-09-16

    Orbit Covariance Estimation and ANalysis (OCEAN) high precision orbit deter- mination tool in order to determine the suitability of each model for...Covariance Estimation and ANalysis (OCEAN) software was used to preform high precision orbit estimations. OCEAN is a highly configurable, database...lowest RMS position difference for each time span is highlighted in bold text . The Jacchia-Bowman 2008 models are labeled as JB08, the NRLMSISE-00

  19. Design of High-Precision Frequency Measure System Based on CPLD Time Delay Unit

    Energy Technology Data Exchange (ETDEWEB)

    Feng Qian; Ding Wei; Wang Hao, E-mail: fengqian@eqhb.gov.cn [Institute of Seismology, China Earthquake Administration, 40 Hongshan Road, Wuchang District, Wuhan (China)

    2011-02-01

    Introduced a method for high-precision frequency measurement, which do do not need the complicated measuring control circumstance. CPLD is used for improving the precision of measurement by the method of quantization time-delay. High precision frequency adjustable module based on the method has been used on the photoelectricity data acquisition system. Frequency accuracy is -8.306x10{sup -10}, which meet the requirement of instrument.

  20. Measuring High-Precision Astrometry with the Infrared Array Camera on the Spitzer Space Telescope

    Science.gov (United States)

    Esplin, T. L.; Luhman, K. L.

    2016-01-01

    The Infrared Array Camera (IRAC) on the Spitzer Space Telescope currently offers the greatest potential for high-precision astrometry of faint mid-IR sources across arcminute-scale fields, which would be especially valuable for measuring parallaxes of cold brown dwarfs in the solar neighborhood and proper motions of obscured members of nearby star-forming regions. To more fully realize IRAC's astrometric capabilities, we have sought to minimize the largest sources of uncertainty in astrometry with its 3.6 and 4.5 μm bands. By comparing different routines that estimate stellar positions, we have found that Point Response Function (PRF) fitting with the Spitzer Science Center's Astronomical Point Source Extractor produces both the smallest systematic errors from varying intra-pixel sensitivity and the greatest precision in measurements of positions. In addition, self-calibration has been used to derive new 7th and 8th order distortion corrections for the 3.6 and 4.5 μm arrays of IRAC, respectively. These corrections are suitable for data throughout the mission of Spitzer when a time-dependent scale factor is applied to the corrections. To illustrate the astrometric accuracy that can be achieved by combining PRF fitting with our new distortion corrections, we have applied them to archival data for a nearby star-forming region, arriving at total astrometric errors of ∼20 and 70 mas at signal to noise ratios of 100 and 10, respectively. Based on observations made with the Spitzer Space Telescope, which is operated by the Jet Propulsion Laboratory, California Institute of Technology under a contract with NASA.

  1. Multi-antenna synchronized global navigation satellite system receiver and its advantages in high-precision positioning applications

    Science.gov (United States)

    Dong, Danan; Chen, Wen; Cai, Miaomiao; Zhou, Feng; Wang, Minghua; Yu, Chao; Zheng, Zhengqi; Wang, Yuanfei

    2016-12-01

    The multi-antenna synchronized global navigation satellite system receiver is a high precision, low cost, and widely used emerging receiver. Using this type of receiver, the satellite and receiver clock errors can be eliminated simultaneously by forming between antenna single-differences, which is equivalent to the conventional double-difference model. However, current multi-antenna synchronized global navigation satellite system receiver products have not fully realized their potential to achieve better accuracy, efficiency, and broader applications. This paper introduces the conceptual design and derivable products of multi-antenna synchronized global navigation satellite system receivers involving the aspects of attitude determination, multipath effect mitigation, phase center variation correction, and ground-based carrier phase windup calibration. Through case studies, the advantages of multi-antenna synchronized global navigation satellite system receivers in high-precision positioning applications are demonstrated.

  2. High-precision 40Ar/39Ar age for the Jehol Biota

    Science.gov (United States)

    Chang, S.; Zhang, H.; Renne, P. R.; Fang, Y.

    2008-12-01

    Abundant fossils of the terrestrial Jehol Biota, including plants, insects, dinosaurs, birds, mammals and freshwater invertebrates, were discovered from the Yixian Formation and the overlying Jiufotang Formation in Inner Mongolia, Hebei Province and Liaoning Province, northeastern China. Because of the exceptional preservation of fossils, the Jehol Biota is one of the most important Mesozoic fossil outcrops and referred to as a "Mesozoic Pompeii". The Jehol Biota has provided a rare opportunity to address questions about the origin of birds, the evolution of feathers and flight, the early diversification of angiosperms and the timing of the radiation of placental mammals. The Tuchengzi Formation, which lies unconformably just below the Yixian Formation and consists mainly of variegated sandstones, is less fossiliferous than the two overlying formations. However, dinosaur tracks, silicified wood and compressed plants are found in this formation. A systematic 40Ar/39Ar dating of the Yixian and the Jiufotang formations was undertaken to provide a framework for understanding the timing and duration of the Jehol Biota and evolutionary events represented within it. Furthermore, determining the absolute age of the Tuchengzi Formation provides information to interpret abundant dinosaur tracks within and provide better age constrains for the beginning of the Jehol Biota. Here we present robust high-precision 40Ar/39Ar data for six tuff samples and two basalt samples collected from the Tuchengzi, the Yixian and the Jiufotang formations near the classic outcrops in western Liaoning, NE China. We obtain an age of 139.5 ± 1.0 Ma for the uppermost Tuchengzi Formation, an age of 129.7 ± 0.5 Ma for a basaltic lava from the bottom of the Yixian Formation and an age of 122.1 ± 0.3 Ma for a tuff from the base of the overlying Jiufotang Formation. Our data indicate that the Yixian Formation was deposited during the Early Cretaceous, the Barremian to early Aptian, within a time span

  3. 高精度地下水位监测仪%High Precision Groundwater Level Monitor

    Institute of Scientific and Technical Information of China (English)

    钟佳迅; 庹先国; 王洪辉; 张兆义; 张贵宇

    2012-01-01

    Through studying the change of groundwater on the influence of the geological hazards, such as landslide, a high precision groundwater level monitor was designed. The monitor took advantage of static-pressure water level sensor to get ground-water level information. By means of sophisticated I/V conversion, high precision A/D conversion, high stability reference voltage and cooperating with curve fitting method, it realized the high precision collection of groundwater level information, and the system error was less than 1 mm. In the actual application, the instrument highlighted its advantages such as high precision, stable performance, small volume,installation flexible,convenient operation,etc. The monitor can be applied to all kinds of monitoring wells very well,and used in geological disaster monitoring.%通过地下水位变化对滑坡等地质灾害的影响研究,设计了一种高精度地下水位监测仪器.仪器采用静压力式水位传感器获取地下水位信息,通过精密I/V转换、高精度A/D转换及高稳定性基准电压,并配合曲线拟合方法,实现了地下水位信息的高精度采集,误差≤1 mm.在实际应用中,仪器突出了精度高、性能稳定、体积小、安装灵活、操作方便等优点,对各类监测井具有很强的适应性,适合用于地质灾害监测.

  4. High precision during food recruitment of experienced (reactivated) foragers in the stingless bee Scaptotrigona mexicana (Apidae, Meliponini)

    Science.gov (United States)

    Sánchez, Daniel; Nieh, James C.; Hénaut, Yann; Cruz, Leopoldo; Vandame, Rémy

    Several studies have examined the existence of recruitment communication mechanisms in stingless bees. However, the spatial accuracy of location-specific recruitment has not been examined. Moreover, the location-specific recruitment of reactivated foragers, i.e., foragers that have previously experienced the same food source at a different location and time, has not been explicitly examined. However, such foragers may also play a significant role in colony foraging, particularly in small colonies. Here we report that reactivated Scaptotrigona mexicana foragers can recruit with high precision to a specific food location. The recruitment precision of reactivated foragers was evaluated by placing control feeders to the left and the right of the training feeder (direction-precision tests) and between the nest and the training feeder and beyond it (distance-precision tests). Reactivated foragers arrived at the correct location with high precision: 98.44% arrived at the training feeder in the direction trials (five-feeder fan-shaped array, accuracy of at least +/-6° of azimuth at 50 m from the nest), and 88.62% arrived at the training feeder in the distance trials (five-feeder linear array, accuracy of at least +/-5 m or +/-10% at 50 m from the nest). Thus, S. mexicana reactivated foragers can find the indicated food source at a specific distance and direction with high precision, higher than that shown by honeybees, Apis mellifera, which do not communicate food location at such close distances to the nest.

  5. A Systematic Study of Zerbar Lake Restoration

    Science.gov (United States)

    Hosseini, Reza; Oveis Torabi, Seyed; Forman Asgharzadeh, Deonna

    2017-04-01

    The beautiful lake of Zerbar, located near Marivan City at the west of Iran, is a freshwater lake with an area of 20 km2 and average depth of 5 meters. The lake is created by regional tectonic activities and is mainly fed with natural spring water from bottom. During the past three decades, regional development has caused much disturbance to the natural environment of the lake and its watershed. Rescuing the lake is crucial to the sustainability of the whole region. The study of Zerbar Restoration was performed with the aim to restore its health indicators. Variety of human activities in the watershed, as well as the multidisciplinary nature of lake restoration studies, made it necessary to develop a systematic approach to conduct the study. In Step I of restoration studies, satellite images were investigated to identify the historical changes of watershed during the past 30 years. Meanwhile, documents since 50 years ago were studied. Results indicate that farmland and graze land areas have been relatively constant during the past 50 years. Also, the area of lake, its riparian canes and floating plants have not changed much. In fact, the only significant land use change observed was the significant spread of Marivan City that has stretched toward the lake. The main physical variation to the lake has been elevating the southern edge of the lake by a constructing a landfill dam which was done to control the lake's overflow discharge for irrigation of downstream farmland development. Step II consists of studies performed by disciplines of water resources, hydrogeology, water quality, wetland and watershed ecology, agriculture, animal farming and fishery. Study results indicate that eutrophication (TSL>100), mainly caused by sewage from Marivan City and the surrounding rural areas has been the main reason for lake ecosystem degradation. DPSIR framework, as a novel approach in lake restoration, was applied to synthesize the study results of different disciplines in a

  6. High-Precision Calibration of Electron Beam Energy from the Hefei Light Source Using Spin Resonant Depolarization

    Science.gov (United States)

    Lan, Jie-Qin; Xu, Hong-Liang

    2014-12-01

    The electron beam energy at the Hefei Light Source (HLS) in the National Synchrotron Radiation Laboratory is highly precisely calibrated by using the method of spin resonant depolarization for the first time. The spin tune and the beam energy are determined by sweeping the frequency of a radial rf stripline oscillating magnetic field to artificially excite a spin resonance and depolarize the beam. The resonance signal is recognized by observing the sudden change of the Touschek loss counting rate of the beam. The possible systematic errors of the experiment are presented and the accuracy of the calibrated energy is shown to be about 10-4. A series of measurements show that the energy stability of the machine is of the order of 9 × 10-3.

  7. A High Precision Position Sensor Design and Its Signal Processing Algorithm for a Maglev Train

    Directory of Open Access Journals (Sweden)

    Wensen Chang

    2012-04-01

    Full Text Available High precision positioning technology for a kind of high speed maglev train with an electromagnetic suspension (EMS system is studied. At first, the basic structure and functions of the position sensor are introduced and some key techniques to enhance the positioning precision are designed. Then, in order to further improve the positioning signal quality and the fault-tolerant ability of the sensor, a new kind of discrete-time tracking differentiator (TD is proposed based on nonlinear optimal control theory. This new TD has good filtering and differentiating performances and a small calculation load. It is suitable for real-time signal processing. The stability, convergence property and frequency characteristics of the TD are studied and analyzed thoroughly. The delay constant of the TD is figured out and an effective time delay compensation algorithm is proposed. Based on the TD technology, a filtering process is introduced in to improve the positioning signal waveform when the sensor is under bad working conditions, and a two-sensor switching algorithm is designed to eliminate the positioning errors caused by the joint gaps of the long stator. The effectiveness and stability of the sensor and its signal processing algorithms are proved by the experiments on a test train during a long-term test run.

  8. A high precision position sensor design and its signal processing algorithm for a maglev train.

    Science.gov (United States)

    Xue, Song; Long, Zhiqiang; He, Ning; Chang, Wensen

    2012-01-01

    High precision positioning technology for a kind of high speed maglev train with an electromagnetic suspension (EMS) system is studied. At first, the basic structure and functions of the position sensor are introduced and some key techniques to enhance the positioning precision are designed. Then, in order to further improve the positioning signal quality and the fault-tolerant ability of the sensor, a new kind of discrete-time tracking differentiator (TD) is proposed based on nonlinear optimal control theory. This new TD has good filtering and differentiating performances and a small calculation load. It is suitable for real-time signal processing. The stability, convergence property and frequency characteristics of the TD are studied and analyzed thoroughly. The delay constant of the TD is figured out and an effective time delay compensation algorithm is proposed. Based on the TD technology, a filtering process is introduced in to improve the positioning signal waveform when the sensor is under bad working conditions, and a two-sensor switching algorithm is designed to eliminate the positioning errors caused by the joint gaps of the long stator. The effectiveness and stability of the sensor and its signal processing algorithms are proved by the experiments on a test train during a long-term test run.

  9. Refining Parameters of the XO-5 Planetary System with High-Precision Transit Photometry

    CERN Document Server

    Maciejewski, G; Adam, Ch; Raetz, St; Neuhaeuser, R

    2011-01-01

    Studies of transiting extrasolar planets offer an unique opportunity to get to know the internal structure of those worlds. The transiting exoplanet XO-5 b was found to have an anomalously high Safronov number and surface gravity. Our aim was to refine parameters of this intriguing system and search for signs of transit timing variations. We gathered high-precision light curves of two transits of XO-5 b. Assuming three different limb darkening laws, we found the best-fitting model and redetermined parameters of the system, including planet-to-star radius ratio, impact parameter and central time of transits. Error estimates were derived by the prayer bead method and Monte Carlo simulations. Although system's parameters obtained by us were found to agree with previous studies within one sigma, the planet was found to be notable smaller with the radius of 1.03+0.06-0.05 Jupiter radii. Our results confirm the high Safronov number and surface gravity of the planet. With two new mid-transit times, the ephemeris was...

  10. High-precision mass measurements of {sup 25}Al and {sup 30}P at JYFLTRAP

    Energy Technology Data Exchange (ETDEWEB)

    Canete, L.; Kankainen, A.; Eronen, T.; Gorelov, D.; Hakala, J.; Jokinen, A.; Kolhinen, V.S.; Koponen, J.; Moore, I.D.; Reinikainen, J.; Rinta-Antila, S. [University of Jyvaskylae (Finland)

    2016-05-15

    The masses of the astrophysically relevant nuclei {sup 25}Al and {sup 30}P have been measured with a Penning trap for the first time. The mass-excess values for {sup 25}Al (Δ=-8915.962(63) keV) and {sup 30}P (Δ=-20200.854(64) keV) obtained with the JYFLTRAP double Penning trap mass spectrometer are in good agreement with the Atomic Mass Evaluation 2012 values but ∼5-10 times more precise. A high precision is required for calculating resonant proton-capture rates of astrophysically important reactions {sup 25}Al(p,γ){sup 26}Si and {sup 30}P(p,γ){sup 31}S. In this work, Q{sub (p,γ)}=5513.99(13) keV and Q{sub (p,γ)}=6130.64(24) keV were obtained for {sup 25}Al and {sup 30}P, respectively. The effect of the more precise values on the resonant proton-capture rates has been studied. In addition to nuclear astrophysics, the measured Q{sub EC} value of {sup 25}Al, 4276.805(45) keV, is relevant for studies of T=1/2 mirror beta decays which have a potential to be used to test the Conserved Vector Current hypothesis. (orig.)

  11. Polarization measurement analysis III. Analysis of the polarization angle dispersion function with high precision polarization data

    CERN Document Server

    Alina, D; Ristorcelli, I; Bernard, J -P; Levrier, F; Abdikamalov, E

    2016-01-01

    High precision polarization measurements open new opportunities for the study of the magnetic field structure as traced by polarimetric measurements of the interstellar dust emission. Polarization parameters suffer from bias in the presence of measurement noise. It is critical to take into account all the information available in the data in order to accurately derive these parameters. The goal of this paper is to characterize the bias on the polarization angle dispersion function that is used to study the spatial coherence of the polarization angle. We characterize, for the first time, the bias on the conventional estimator of the polarization angle dispersion function (S hereafter) and show that it can be positive or negative depending on the true value. Monte Carlo simulations are performed in order to explore the impact of the noise properties of the polarization data, as well as the impact of the distribution of the true polarization angles on the bias. We show that in the case where the ellipticity of t...

  12. High precision spectroscopy of pionic and antiprotonic atoms; Spectroscopie de precision des atomes pioniques et antiprotoniques

    Energy Technology Data Exchange (ETDEWEB)

    El-Khoury, P

    1998-04-15

    The study of exotic atoms, in which an orbiting electron of a normal atom is replaced by a negatively charged particle ({pi}{sup -}, {mu}{sup -}, p, {kappa}{sup -}, {sigma}{sup -},...) may provide information on the orbiting particle and the atomic nucleus, as well as on their interaction. In this work, we were interested in pionic atoms ({pi}{sup -14} N) on the one hand in order to determine the pion mass with high accuracy (4 ppm), and on the other hand in antiprotonic atoms (pp-bar) in order to study the strong nucleon-antinucleon interaction at threshold. In this respect, a high-resolution crystal spectrometer was coupled to a cyclotron trap which provides a high stop density for particles in gas targets at low pressure. Using curved crystals, an extended X-ray source could be imaged onto the detector. Charge-Coupled Devices were used as position sensitive detectors in order to measure the Bragg angle of the transition to a high precision. The use of gas targets resolved the ambiguity owing to the number of K electrons for the value of the pion mass, and, for the first time, strong interaction shift and broadening of the 2p level in antiprotonic hydrogen were measured directly. (author)

  13. High-Precision Registration of Point Clouds Based on Sphere Feature Constraints.

    Science.gov (United States)

    Huang, Junhui; Wang, Zhao; Gao, Jianmin; Huang, Youping; Towers, David Peter

    2016-12-30

    Point cloud registration is a key process in multi-view 3D measurements. Its precision affects the measurement precision directly. However, in the case of the point clouds with non-overlapping areas or curvature invariant surface, it is difficult to achieve a high precision. A high precision registration method based on sphere feature constraint is presented to overcome the difficulty in the paper. Some known sphere features with constraints are used to construct virtual overlapping areas. The virtual overlapping areas provide more accurate corresponding point pairs and reduce the influence of noise. Then the transformation parameters between the registered point clouds are solved by an optimization method with weight function. In that case, the impact of large noise in point clouds can be reduced and a high precision registration is achieved. Simulation and experiments validate the proposed method.

  14. Research Progress of Key Technology of High-Speed and High Precision Motorized Spindles

    Institute of Scientific and Technical Information of China (English)

    XIONG Wan-li; MI Hai-qing; HUANG Hon-gwu

    2005-01-01

    High speed machining and high precision machining are two tendencies of the manufacturing technology worldwide. The motorized spindle is the core component of the machine tools for achieving the high speed and high precise machining, which affects the general development level of the machine tools to a great extent. Progress of the key techniques is reviewed in this paper, in which the high speed and high precision spindle bearings, the dynamical and thermal characteristics of spindles, the design technique of the high frequency motors and the drivers, the anti-electromagnetic damage technique of the motors, and the machining and assembling technique are involved. Finally, tha development tendencies of the motorized spindles are presented.

  15. A High Precision Comprehensive Evaluation Method for Flood Disaster Loss Based on Improved Genetic Programming

    Institute of Scientific and Technical Information of China (English)

    ZHOU Yuliang; LU Guihua; JIN Juliang; TONG Fang; ZHOU Ping

    2006-01-01

    Precise comprehensive evaluation of flood disaster loss is significant for the prevention and mitigation of flood disasters. Here, one of the difficulties involved is how to establish a model capable of describing the complex relation between the input and output data of the system of flood disaster loss. Genetic programming (GP) solves problems by using ideas from genetic algorithm and generates computer programs automatically. In this study a new method named the evaluation of the grade of flood disaster loss (EGFD) on the basis of improved genetic programming (IGP) is presented (IGPEGFD). The flood disaster area and the direct economic loss are taken as the evaluation indexes of flood disaster loss. Obviously that the larger the evaluation index value, the larger the corresponding value of the grade of flood disaster loss is. Consequently the IGP code is designed to make the value of the grade of flood disaster be an increasing function of the index value. The result of the application of the IGP-EGFD model to Henan Province shows that a good function expression can be obtained within a bigger searched function space; and the model is of high precision and considerable practical significance.Thus, IGP-EGFD can be widely used in automatic modeling and other evaluation systems.

  16. High-precision gravity measurements using absolute and relative gravimeters at Mount Etna (Sicily, Italy

    Directory of Open Access Journals (Sweden)

    Ciro Del Negro

    2011-12-01

    Full Text Available Accurate detection of time gravity changes attributable to the dynamics of volcanoes requires high-precision gravity measurements. With the aim of improving the quality of data from the Mount Etna gravity network, we used both absolute and relative gravimeters in a hybrid method. In this report, some of the techniques for gravity surveys are reviewed, and the results related to each method are compared. We show how the total uncertainty estimated for the gravity measurements performed with this combined use of absolute and relative gravimeters is roughly comparable to that calculated when the measurements are acquired using only relative gravimeters (the traditional method. However, the data highlight how the hybrid approach improves the measurement capabilities for surveying the Mount Etna volcanic area. This approach enhances the accuracy of the data, and then of the four-dimensional surveying, which minimizes ambiguities inherent in the gravity measurements. As a case study, we refer to two gravity datasets acquired in 2005 and 2010 from the western part of the Etna volcano, which included five absolute and 13 relative stations of the Etna gravity network.

  17. High-precision and fast computation of Jacobi-Fourier moments for image description.

    Science.gov (United States)

    Camacho-Bello, C; Toxqui-Quitl, C; Padilla-Vivanco, A; Báez-Rojas, J J

    2014-01-01

    A high-precision and fast algorithm for computation of Jacobi-Fourier moments (JFMs) is presented. A fast recursive method is developed for the radial polynomials that occur in the kernel function of the JFMs. The proposed method is numerically stable and very fast in comparison with the conventional direct method. Moreover, the algorithm is suitable for computation of the JFMs of the highest orders. The JFMs are generic expressions to generate orthogonal moments changing the parameters α and β of Jacobi polynomials. The quality of the description of the proposed method with α and β parameters known is studied. Also, a search is performed of the best parameters, α and β, which significantly improves the quality of the reconstructed image and recognition. Experiments are performed on standard test images with various sets of JFMs to prove the superiority of the proposed method in comparison with the direct method. Furthermore, the proposed method is compared with other existing methods in terms of speed and accuracy.

  18. High precision quantum-chemical treatment of adsorption: Benchmarking physisorption of molecular hydrogen on graphane

    Science.gov (United States)

    Usvyat, Denis

    2015-09-01

    A multilevel hierarchical ab initio protocol for calculating adsorption on non-conducting surfaces is presented. It employs fully periodic treatment, which reaches local Møller-Plesset perturbation theory of second order (MP2) with correction for the basis set incompleteness via the local F12 technique. Post-MP2 corrections are calculated using finite clusters. That includes the coupled cluster treatment in the local and canonical frameworks (up to perturbative quadruples) and correlated core (with MP2). Using this protocol, the potential surface of hydrogen molecules adsorbed on graphane was computed. According to the calculations, hydrogen molecules are adsorbed on graphane in a perpendicular to the surface orientation with the minimum of the potential surface of around -3.6 kJ/mol located at the distance of 3.85 Å between the bond center of the hydrogen molecule and the mid-plane of graphane. The adsorption sites along the path from the downward-pointing carbon to the ring center of the graphane are energetically virtually equally preferable, which can enable nearly free translations of hydrogen molecules along these paths. Consequently, the hydrogen molecules on graphane most likely form a non-commensurate monolayer. The analysis of the remaining errors reveals a very high accuracy of the computed potential surface with an error bar of a few tenths of a kJ/mol. The obtained results are a high-precision benchmark for further theoretical and experimental studies of hydrogen molecules interacting with graphane.

  19. Design principle of high-precision flexure mechanisms based on parasitic-motion compensation

    Science.gov (United States)

    Li, Shouzhong; Yu, Jingjun

    2014-07-01

    In design of flexure mechanism, diminishing the parasitic-motion is a key point to improve the accuracy. However, most of existing topics concentrate on improving the accuracy of linear-motion flexure mechanisms via compensating the parasitic error, but few research the multi-dimensional flexure mechanisms. A general design principle and method for high-precision flexure mechanisms based on the parasitic-motion compensation is presented, and the proposed method can compensate the parasitic rotation in company with translation, or the parasitic translation in company with rotation, or both. The crucial step for the method is that the parasitic motion of a flexure mechanism is formulated and evaluated in terms of its compliance. The overall compliance matrix of a general flexure mechanism is formulated by using screw theory firstly, then the criteria for the parasitic motions is introduced by analyzing the characteristics of the resultant compliance matrix as well as with aid of the concept of instantaneous rotation center. Subsequently, a compliance-based compensation approach for reducing parasitic-motion is addressed as the most important part. The design principles and procedure are further discussed to help with improving the accuracy of flexure mechanisms, and case studies are provided to illustrate this method. Finally, an analytical verification is provided to demonstrate that the symmetry design philosophy widely used in flexure design can effectively improve accuracy in terms of the proposed method. The proposed compensation method can be well used to diminish the parasitic-motion of multi-dimensional flexure mechanisms.

  20. High-Precision Isotope Ratio Measurements of Sub-Picogram Actinide Samples

    Science.gov (United States)

    Pollington, A. D.; Kinman, W.

    2016-12-01

    One of the most exciting trends in analytical geochemistry over the past decade is the push towards smaller and smaller sample sizes while simultaneously achieving high precision isotope ratio measurements. This trend has been driven by advances in clean chemistry protocols, and by significant breakthroughs in mass spectrometer ionization efficiency and detector quality (stability and noise for low signals). In this presentation I will focus on new techniques currently being developed at Los Alamos National Laboratory for the characterization of ultra-small samples (pg, fg, ag), with particular focus on actinide measurements by MC-ICP-MS. Analyses of U, Pu, Th and Am are routinely carried out in our facility using multi-ion counting techniques. I will describe some of the challenges associated with using exclusively ion counting methods (e.g., stability, detector cross calibration, etc.), and how we work to mitigate them. While the focus of much of the work currently being carried out is in the broad field of nuclear forensics and safeguards, the techniques that are being developed are directly applicable to many geologic questions that require analyses of small samples of U and Th, for example. In addition to the description of the technique development, I will present case studies demonstrating the precision and accuracy of the method as applied to real-world samples.

  1. Frontend electronics for high-precision single photo-electron timing using FPGA-TDCs

    Energy Technology Data Exchange (ETDEWEB)

    Cardinali, M., E-mail: cardinal@kph.uni-mainz.de [Institut für Kernphysik, Johannes Gutenberg-University Mainz, Mainz (Germany); Helmholtz Institut Mainz, Mainz (Germany); Dzyhgadlo, R.; Gerhardt, A.; Götzen, K.; Hohler, R.; Kalicy, G.; Kumawat, H.; Lehmann, D.; Lewandowski, B.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Ugur, C.; Zühlsdorf, M. [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt (Germany); Dodokhov, V.Kh. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Britting, A. [Friedrich Alexander-University of Erlangen-Nuremberg, Erlangen (Germany); and others

    2014-12-01

    The next generation of high-luminosity experiments requires excellent particle identification detectors which calls for Imaging Cherenkov counters with fast electronics to cope with the expected hit rates. A Barrel DIRC will be used in the central region of the Target Spectrometer of the planned PANDA experiment at FAIR. A single photo-electron timing resolution of better than 100 ps is required by the Barrel DIRC to disentangle the complicated patterns created on the image plane. R and D studies have been performed to provide a design based on the TRB3 readout using FPGA-TDCs with a precision better than 20 ps RMS and custom frontend electronics with high-bandwidth pre-amplifiers and fast discriminators. The discriminators also provide time-over-threshold information thus enabling walk corrections to improve the timing resolution. Two types of frontend electronics cards optimised for reading out 64-channel PHOTONIS Planacon MCP-PMTs were tested: one based on the NINO ASIC and the other, called PADIWA, on FPGA discriminators. Promising results were obtained in a full characterisation using a fast laser setup and in a test experiment at MAMI, Mainz, with a small scale DIRC prototype. - Highlights: • Frontend electronics for Cherenkov detectors have been developed. • FPGA-TDCs have been used for high precision timing. • Time over threshold has been utilised for walk correction. • Single photo-electron timing resolution less than 100 ps has been achieved.

  2. High precision $^{89}$Y($\\alpha$,$\\alpha$)$^{89}$Y scattering at low energies

    CERN Document Server

    Kiss, G G; \\, Zs; Fülöp,; Galaviz, D; Gyürky, Gy; Elekes, Z; Somorjai, E; Kretschmer, A; Sonnabend, K; Zilges, A; Avrigeanu, M

    2010-01-01

    Elastic scattering cross sections of the $^{89}$Y($\\alpha$,$\\alpha$)$^{89}$Y reaction have been measured at energies E$_{c.m.}$ = 15.51 and 18.63 MeV. The high precision data for the semi-magic $N = 50$ nucleus $^{89}$Y are used to derive a local potential and to evaluate the predictions of global and regional $\\alpha$-nucleus potentials. The variation of the elastic alpha scattering cross sections along the $N = 50$ isotonic chain is investigated by a study of the ratios of angular distributions for $^{89}$Y($\\alpha$,$\\alpha$)$^{89}$Y and $^{92}$Mo($\\alpha$,$\\alpha$)$^{92}$Mo at E$_{c.m.} \\approx$ 15.51 and 18.63 MeV. This ratio is a very sensitive probe at energies close to the Coulomb barrier, where scattering data alone is usually not enough to characterize the different potentials. Furthermore, $\\alpha$-cluster states in $^{93}$Nb = $^{89}$Y $\\otimes$ $\\alpha$ are investigated.

  3. Development of high precision laser measurement to Space Debris and Applications in SHAO

    Science.gov (United States)

    Zhang, Zhongping; Chen, Juping; Xiong, Yaoheng; Han, Xingwei

    2016-07-01

    Artificial space debris has become the focus during the space exploration because of producing the damage for the future active spacecrafts and high precision measurement for space debris are required for debris surveillance and collision avoidance. Laser ranging technology is inherently high accurate and will play an important role in precise orbit determination, accurate catalog of space debris. Shanghai Astronomical Observatory (SHAO) of CAS, has been developing the technology of laser measurement to space debris for several years. According to characteristics of laser echoes from space debris and the experiences of relevant activities, high repetition rate, high power laser system and low dark noise APD detector with high quantum efficiency and high transmissivity of narrow bandwidth spectral filter are applied to laser measurement to space debris in SHAO. With these configurations, great achievements of laser measurement to space debris are made with hundreds of passes of laser data from space debris in the distance between 500km and 2500km with Radar Cross Section (RCS) of more than 10 m^{2} to less than 0.5m^{2} at the measuring precision of less than 1m (RMS). For better application of laser ranging technology, Chinese Space Debris Observation network, consisting of Shanghai, Changchun and Kunming station, has been preliminary developed and the coordinated observation has been performed to increase the measuring efficiency for space debris. It is referred from data that laser ranging technology can be as the essential high accuracy measurement technology in the study of space debris.

  4. High precision quantum-chemical treatment of adsorption: Benchmarking physisorption of molecular hydrogen on graphane

    Energy Technology Data Exchange (ETDEWEB)

    Usvyat, Denis, E-mail: denis.usvyat@chemie.uni-regensburg.de [Institute for Physical and Theoretical Chemistry, Universität Regensburg, Universitätsstrasse 31, D-93040 Regensburg (Germany)

    2015-09-14

    A multilevel hierarchical ab initio protocol for calculating adsorption on non-conducting surfaces is presented. It employs fully periodic treatment, which reaches local Møller-Plesset perturbation theory of second order (MP2) with correction for the basis set incompleteness via the local F12 technique. Post-MP2 corrections are calculated using finite clusters. That includes the coupled cluster treatment in the local and canonical frameworks (up to perturbative quadruples) and correlated core (with MP2). Using this protocol, the potential surface of hydrogen molecules adsorbed on graphane was computed. According to the calculations, hydrogen molecules are adsorbed on graphane in a perpendicular to the surface orientation with the minimum of the potential surface of around −3.6 kJ/mol located at the distance of 3.85 Å between the bond center of the hydrogen molecule and the mid-plane of graphane. The adsorption sites along the path from the downward-pointing carbon to the ring center of the graphane are energetically virtually equally preferable, which can enable nearly free translations of hydrogen molecules along these paths. Consequently, the hydrogen molecules on graphane most likely form a non-commensurate monolayer. The analysis of the remaining errors reveals a very high accuracy of the computed potential surface with an error bar of a few tenths of a kJ/mol. The obtained results are a high-precision benchmark for further theoretical and experimental studies of hydrogen molecules interacting with graphane.

  5. High-precision predictions for the light CP-even Higgs boson mass of the MSSM

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, T.; Hollik, W. [Max-Planck-Institut fuer Physik, Muenchen (Germany); Heinemeyer, S. [Instituto de Fisica de Cantabria (CSIC-UC), Santander (Spain); Rzehak, H. [Freiburg Univ. (Germany). Physikalisches Inst.; Weiglein, G. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2014-03-15

    For the interpretation of the signal discovered in the Higgs searches at the LHC it will be crucial in particular to discriminate between the minimal Higgs sector realised in the Standard Model (SM) and its most commonly studied extension, the Minimal Supersymmetric SM (MSSM). The measured mass value, having already reached the level of a precision observable with an experimental accuracy of about 500 MeV, plays an important role in this context. In the MSSM the mass of the light CP-even Higgs boson, M{sub h}, can directly be predicted from the other parameters of the model. The accuracy of this prediction should at least match the one of the experimental result. The relatively high mass value of about 126 GeV has led to many investigations where the scalar top quarks are in the multi-TeV range. We improve the prediction for M{sub h} in the MSSM by combining the existing fixed-order result, comprising the full one-loop and leading and subleading two-loop corrections, with a resummation of the leading and subleading logarithmic contributions from the scalar top sector to all orders. In this way for the first time a high-precision prediction for the mass of the light CP-even Higgs boson in the MSSM is possible all the way up to the multi-TeV region of the relevant supersymmetric particles. The results are included in the code FeynHiggs.

  6. Detailed seismotectonic analysis of Sumatra subduction zone revealed by high precision earthquake location

    Science.gov (United States)

    Sagala, Ricardo Alfencius; Harjadi, P. J. Prih; Heryandoko, Nova; Sianipar, Dimas

    2017-07-01

    Sumatra was one of the most high seismicity regions in Indonesia. The subduction of Indo-Australian plate beneath Eurasian plate in western Sumatra contributes for many significant earthquakes that occur in this area. These earthquake events can be used to analyze the seismotectonic of Sumatra subduction zone and its system. In this study we use teleseismic double-difference method to obtain more high precision earthquake distribution in Sumatra subduction zone. We use a 3D nested regional-global velocity model. We use a combination of data from both of ISC (International Seismological Center) and BMKG (Agency for Meteorology Climatology and Geophysics, Indonesia). We successfully relocate about 6886 earthquakes that occur on period of 1981-2015. We consider that this new location is more precise than the regular bulletin. The relocation results show greatly reduced of RMS residual of travel time. Using this data, we can construct a new seismotectonic map of Sumatra. A well-built geometry of subduction slab, faults and volcano arc can be obtained from the new bulletin. It is also showed that at a depth of 140-170 km, there is many events occur as moderate-to-deep earthquakes, and we consider about the relation of the slab's events with volcanic arc and inland fault system. A reliable slab model is also built from regression equation using new relocated data. We also analyze the spatial-temporal of seismotectonic using b-value mapping that inspected in detail horizontally and vertically cross-section.

  7. Effect of stellar activity on the high precision transit light curve

    Directory of Open Access Journals (Sweden)

    Oshagh, M.

    2015-01-01

    Full Text Available Stellar activity features such as spots and plages can create difficulties in determining planetary parameters through spectroscopic and photometric observations. The overlap of a transiting planet and a stellar spot, for instance, can produce anomalies in the transit light curve that may lead to inaccurate estimation of the transit duration, depth, and timing. Such inaccuracies can affect the precise derivation of the planet’s radius. In this talk we will present the results of a quantitative study on the effects of stellar spots on high precision transit light curves. We show that spot anomalies can lead to the estimate of a planet radius that is 4% smaller than the real value. The effects on the transit duration can also be of the order of 4%, longer or shorter. Depending on the size and distribution of spots, anomalies can also produce transit timing variations with significant amplitudes. For instance, TTVs with signal amplitudes of 200 seconds can be produced by spots as large as the largest sunspot. Finally, we examine the impact of active regions on the transit depth measurements in different wavelengths, in order to probe the impact of this effect on transmission spectroscopy measurements. We show that significant (up to 10% underestimation/overestimation of the planet-to-star radius ratio can be measured, especially in the short wavelength regime.

  8. High precision, medium flux rate CZT spectroscopy for coherent scatter imaging

    Science.gov (United States)

    Greenberg, Joel A.; Hassan, Mehadi; Brady, David J.; Iniewski, Kris

    2016-05-01

    CZT detectors are primary candidates for many next-generation X-ray imaging systems. These detectors are typically operated in either a high precision, low flux spectroscopy mode or a low precision, high flux photon counting mode. We demonstrate a new detector configuration that enables operation in a high precision, medium flux spectroscopy mode, which opens the potential for a variety of new applications in medical imaging, non-destructive testing and baggage scanning. In particular, we describe the requirements of a coded aperture coherent scattering X-ray system that can perform fast imaging with accurate material discrimination.

  9. Diamond turning of high-precision roll-to-roll imprinting molds for fabricating subwavelength gratings

    Science.gov (United States)

    Liu, Chun-Wei; Yan, Jiwang; Lin, Shih-Chieh

    2016-06-01

    Diamond turning of high-precision molds is a vital process for the roll-to-roll-based ultraviolet resin imprinting process in fabricating subwavelength gratings. The effects of the grating shape and grating period on diffraction efficiencies and diffraction angles were simulated. Experiments were then conducted to examine the effects of shape design, grating period, and cutting speed on machinability of the mold. According to the optical measurement results, the performance of the subwavelength gratings matched the design well at various incident angles. The results confirm that diamond turning of high-precision molds is a feasible approach for ensuring the continual mass production of subwavelength gratings.

  10. High precision planar waveguide propagation loss measurement technique using a Fabry-Perot cavity

    DEFF Research Database (Denmark)

    Feuchter, Thomas; Thirstrup, Carsten

    1994-01-01

    A high precision measurement technique for characterizing the propagation loss in silica low-loss optical waveguides, based on measuring the contrast of a Fabry-Perot cavity, is demonstrated. The cavity consists of the waveguide coupled to two polarization-maintaining fibers, each end facet coated...

  11. A high-precision calculation method for interface normal and curvature on an unstructured grid

    Science.gov (United States)

    Ito, Kei; Kunugi, Tomoaki; Ohno, Shuji; Kamide, Hideki; Ohshima, Hiroyuki

    2014-09-01

    In the volume-of-fluid algorithm, the calculations of the interface normal and curvature are crucially important for accurately simulating interfacial flows. However, few methods have been proposed for the high-precision interface calculation on an unstructured grid. In this paper, the authors develop a height function method that works appropriately on an unstructured grid. In the process, the definition of the height function is discussed, and the high-precision calculation method of the interface normal is developed to meet the necessary condition for a second-order method. This new method has highly reduced computational cost compared with a conventional high-precision method because the interface normal calculation is completed by solving relatively simple algebraic equations. The curvature calculation method is also discussed and the approximated quadric curve of an interface is employed to calculate the curvature. Following a basic verification, the developed height function method is shown to successfully provide superior calculation accuracy and highly reduced computational cost compared with conventional calculation methods in terms of the interface normal and curvature. In addition, the height function method succeeds in calculating accurately the slotted-disk revolution problem and the oscillating drop on unstructured grids. Therefore, the developed height function method is confirmed to be an efficient technique for the high-precision numerical simulation of interfacial flows on an unstructured grid.

  12. High-precision photometry by telescope defocusing - I. The transiting planetary system WASP-5

    DEFF Research Database (Denmark)

    Southworth, J.; Hinse, T. C.; Jørgensen, U. G.;

    2009-01-01

    We present high-precision photometry of two transit events of the extrasolar planetary system WASP-5, obtained with the Danish 1.54-m telescope at European Southern Obseratory La Silla. In order to minimize both random and flat-fielding errors, we defocused the telescope so its point spread...

  13. Optimizing Planning and Delivery of High-Precision Robotic Radiotherapy and Intensity-Modulated Proton Therapy

    NARCIS (Netherlands)

    S. van de Water (Steven)

    2015-01-01

    markdownabstract__Abstract__ High-precision robotic radiotherapy and intensity-modulated proton therapy (IMPT) are two relatively new radiotherapy techniques that particularly aim at a highly localized delivery of a curative dose to the tumor, while achieving excellent sparing of the surrounding

  14. Design of High Precision Horizontal Control Network for Large-Scale Hydropower Project

    Institute of Scientific and Technical Information of China (English)

    ZHANG Zhenglu; LUO Changlin; DENG Yong; XIE Niansheng

    2006-01-01

    A new solution of combination network of GPS and high precise distance measurements with EDM is proposed. Meanwhile, it's inadvisable only using GPS network without distance measurements. Three schemes: terrestrial network, GPS network and combination network are discussed for horizontal control network design of Xiangjiaba Dam in view of precision, reliability, coordinate and outlay in detail.

  15. Analysis of Trace Hydrogen Isotopes in Fusion Fuel Cycle by High Precision Gas Chromatograph

    Institute of Scientific and Technical Information of China (English)

    YANG; Li-ling; YANG; Hong-guang; ZHAO; Wei-wei; HE; Chang-shui; LIU; Zhen-xing; ZHAN; Qin

    2013-01-01

    It is essential to analysis of hydrogen isotopes in the fuel cycle system of fusion reactors,gas chromatography(GC)was found to be an effectively analytical technique.Compared with conventional GC,the high-precision GC with a cryogenic column could achieve fairly good performance to reduce the retention time.

  16. High-precision spectroscopy of the HD+ molecule at the 1-p.p.b. level

    CERN Document Server

    Biesheuvel, J; Hilico, L; Eikema, K S E; Ubachs, W; Koelemeij, J C J

    2016-01-01

    Recently we reported a high precision optical frequency measurement of the (v,L):(0,2)->(8,3) vibrational overtone transition in trapped deuterated molecular hydrogen (HD+) ions at 10 mK temperature. Achieving a resolution of 0.85 parts-per-billion (p.p.b.) we found the experimental value ($\

  17. High precision locating control system based on VCM for Talbot lithography

    Science.gov (United States)

    Yao, Jingwei; Zhao, Lixin; Deng, Qian; Hu, Song

    2016-10-01

    Aiming at the high precision and efficiency requirements of Z-direction locating in Talbot lithography, a control system based on Voice Coil Motor (VCM) was designed. In this paper, we built a math model of VCM and its moving characteristic was analyzed. A double-closed loop control strategy including position loop and current loop were accomplished. The current loop was implemented by driver, in order to achieve the rapid follow of the system current. The position loop was completed by the digital signal processor (DSP) and the position feedback was achieved by high precision linear scales. Feed forward control and position feedback Proportion Integration Differentiation (PID) control were applied in order to compensate for dynamic lag and improve the response speed of the system. And the high precision and efficiency of the system were verified by simulation and experiments. The results demonstrated that the performance of Z-direction gantry was obviously improved, having high precision, quick responses, strong real-time and easily to expend for higher precision.

  18. Optimizing Planning and Delivery of High-Precision Robotic Radiotherapy and Intensity-Modulated Proton Therapy

    NARCIS (Netherlands)

    S. van de Water (Steven)

    2015-01-01

    markdownabstract__Abstract__ High-precision robotic radiotherapy and intensity-modulated proton therapy (IMPT) are two relatively new radiotherapy techniques that particularly aim at a highly localized delivery of a curative dose to the tumor, while achieving excellent sparing of the surrounding he

  19. CLASSIFICATION OF LIDAR DATA FOR GENERATING A HIGH-PRECISION ROADWAY MAP

    Directory of Open Access Journals (Sweden)

    J. Jeong

    2016-06-01

    Full Text Available Generating of a highly precise map grows up with development of autonomous driving vehicles. The highly precise map includes a precision of centimetres level unlike an existing commercial map with the precision of meters level. It is important to understand road environments and make a decision for autonomous driving since a robust localization is one of the critical challenges for the autonomous driving car. The one of source data is from a Lidar because it provides highly dense point cloud data with three dimensional position, intensities and ranges from the sensor to target. In this paper, we focus on how to segment point cloud data from a Lidar on a vehicle and classify objects on the road for the highly precise map. In particular, we propose the combination with a feature descriptor and a classification algorithm in machine learning. Objects can be distinguish by geometrical features based on a surface normal of each point. To achieve correct classification using limited point cloud data sets, a Support Vector Machine algorithm in machine learning are used. Final step is to evaluate accuracies of obtained results by comparing them to reference data The results show sufficient accuracy and it will be utilized to generate a highly precise road map.

  20. Classification of LIDAR Data for Generating a High-Precision Roadway Map

    Science.gov (United States)

    Jeong, J.; Lee, I.

    2016-06-01

    Generating of a highly precise map grows up with development of autonomous driving vehicles. The highly precise map includes a precision of centimetres level unlike an existing commercial map with the precision of meters level. It is important to understand road environments and make a decision for autonomous driving since a robust localization is one of the critical challenges for the autonomous driving car. The one of source data is from a Lidar because it provides highly dense point cloud data with three dimensional position, intensities and ranges from the sensor to target. In this paper, we focus on how to segment point cloud data from a Lidar on a vehicle and classify objects on the road for the highly precise map. In particular, we propose the combination with a feature descriptor and a classification algorithm in machine learning. Objects can be distinguish by geometrical features based on a surface normal of each point. To achieve correct classification using limited point cloud data sets, a Support Vector Machine algorithm in machine learning are used. Final step is to evaluate accuracies of obtained results by comparing them to reference data The results show sufficient accuracy and it will be utilized to generate a highly precise road map.

  1. A high-precision protocol for identification of preschool children at risk for persisting obesity.

    Directory of Open Access Journals (Sweden)

    Toomas Timpka

    Full Text Available BACKGROUND: Recent studies suggest that adolescent adiposity is established already in preadolescence. Earlier studies have confirmed a strong tracking of obesity from adolescence to adulthood. Our aim was to examine the diagnostic accuracy of a population-derived protocol for identification of preschool children at risk for obesity in preadolescence. METHODOLOGY/PRINCIPAL FINDINGS: We analysed data obtained for child health surveillance up to age 5 from 5778 children born in a Swedish county in 1991. The basic data set included age, sex, and weight and height measurements from the regular checkups between ages 1.5 and 5. Data not routinely collected in the child health centre setting were disregarded. The children were at age 10 randomly assigned to protocol derivation and validation cohorts and assessed for obesity according to IOTF criteria. The accuracy of predicting obesity in the validation cohort was measured using decision precision, specificity, and sensitivity. The decision protocol selected 1.4% of preschool children as being at obesity risk. The precision of the protocol at age 10 was 82% for girls and 80% for boys, and the specificity was 100% for both boys and girls. The sensitivity was higher for girls (41% than for boys (21%. The relative risk for obesity at age 10 estimated by the odds ratio for individuals selected by the protocol compared to non-selected peers was 212.6 (95% confidence interval 56.6 to 798.4 for girls and 120.3 (95% CI 24.5 to 589.9 for boys. CONCLUSION/SIGNIFICANCE: A simple and inexpensive decision protocol based on BMI values proved to have high precision and specificity for identification of preschool children at risk for obesity persisting into adolescence, while the sensitivity was low especially for boys. Implementation and further evaluations of the protocol in child health centre settings are warranted.

  2. A near infrared laser frequency comb for high precision Doppler planet surveys

    Directory of Open Access Journals (Sweden)

    Bally J.

    2011-07-01

    Full Text Available Perhaps the most exciting area of astronomical research today is the study of exoplanets and exoplanetary systems, engaging the imagination not just of the astronomical community, but of the general population. Astronomical instrumentation has matured to the level where it is possible to detect terrestrial planets orbiting distant stars via radial velocity (RV measurements, with the most stable visible light spectrographs reporting RV results the order of 1 m/s. This, however, is an order of magnitude away from the precision needed to detect an Earth analog orbiting a star such as our sun, the Holy Grail of these efforts. By performing these observations in near infrared (NIR there is the potential to simplify the search for distant terrestrial planets by studying cooler, less massive, much more numerous class M stars, with a tighter habitable zone and correspondingly larger RV signal. This NIR advantage is undone by the lack of a suitable high precision, high stability wavelength standard, limiting NIR RV measurements to tens or hundreds of m/s [1, 2]. With the improved spectroscopic precision provided by a laser frequency comb based wavelength reference producing a set of bright, densely and uniformly spaced lines, it will be possible to achieve up to two orders of magnitude improvement in RV precision, limited only by the precision and sensitivity of existing spectrographs, enabling the observation of Earth analogs through RV measurements. We discuss the laser frequency comb as an astronomical wavelength reference, and describe progress towards a near infrared laser frequency comb at the National Institute of Standards and Technology and at the University of Colorado where we are operating a laser frequency comb suitable for use with a high resolution H band astronomical spectrograph.

  3. CLASH-VLT: A Highly Precise Strong Lensing Model of the Galaxy Cluster RXC J2248.7-4431 (Abell S1063) and Prospects for Cosmography

    CERN Document Server

    Caminha, G B; Rosati, P; Balestra, I; Karman, W; Lombardi, M; Mercurio, A; Nonino, M; Tozzi, P; Zitrin, A; Biviano, A; Girardi, M; Koekemoer, A M; Melchior, P; Meneghetti, M; Munari, E; Suyu, S H; Umetsu, K; Annunziatella, M; Borgani, S; Broadhurst, T; Caputi, K I; Coe, D; Delgado-Correal, C; Ettori, S; Fritz, A; Frye, B; Gobat, R; Maier, C; Monna, A; Postman, M; Sartoris, B; Seitz, S; Vanzella, E; Ziegler, B

    2015-01-01

    We perform a comprehensive study of the total mass distribution of the galaxy cluster RXCJ2248 ($z=0.348$) with a set of high-precision strong lensing models, which take advantage of extensive spectroscopic information on many multiply lensed systems. In the effort to understand and quantify inherent systematics in parametric strong lensing modelling, we explore a collection of 22 models where we use different samples of multiple image families, parametrizations of the mass distribution and cosmological parameters. As input information for the strong lensing models, we use the CLASH HST imaging data and spectroscopic follow-up observations, carried out with the VIMOS and MUSE spectrographs, to identify bona-fide multiple images. A total of 16 background sources, over the redshift range $1.0-6.1$, are multiply lensed into 47 images, 24 of which are spectroscopically confirmed and belong to 10 individual sources. The cluster total mass distribution and underlying cosmology in the models are optimized by matchin...

  4. High-Precision Surface Inspection: Uncertainty Evaluation within an Accuracy Range of 15μm with Triangulation-based Laser Line Scanners

    Science.gov (United States)

    Dupuis, Jan; Kuhlmann, Heiner

    2014-06-01

    Triangulation-based range sensors, e.g. laser line scanners, are used for high-precision geometrical acquisition of free-form surfaces, for reverse engineering tasks or quality management. In contrast to classical tactile measuring devices, these scanners generate a great amount of 3D-points in a short period of time and enable the inspection of soft materials. However, for accurate measurements, a number of aspects have to be considered to minimize measurement uncertainties. This study outlines possible sources of uncertainties during the measurement process regarding the scanner warm-up, the impact of laser power and exposure time as well as scanner’s reaction to areas of discontinuity, e.g. edges. All experiments were performed using a fixed scanner position to avoid effects resulting from imaging geometry. The results show a significant dependence of measurement accuracy on the correct adaption of exposure time as a function of surface reflectivity and laser power. Additionally, it is illustrated that surface structure as well as edges can cause significant systematic uncertainties.

  5. High-Precision Dispensing of Nanoliter Biofluids on Glass Pedestal Arrays for Ultrasensitive Biomolecule Detection.

    Science.gov (United States)

    Chen, Xiaoxiao; Liu, Yang; Xu, QianFeng; Zhu, Jing; Poget, Sébastien F; Lyons, Alan M

    2016-05-04

    Precise dispensing of nanoliter droplets is necessary for the development of sensitive and accurate assays, especially when the availability of the source solution is limited. Conventional approaches are limited by imprecise positioning, large shear forces, surface tension effects, and high costs. To address the need for precise and economical dispensing of nanoliter volumes, we developed a new approach where the dispensed volume is dependent on the size and shape of defined surface features, thus freeing the dispensing process from pumps and fine-gauge needles requiring accurate positioning. The surface we fabricated, called a nanoliter droplet virtual well microplate (nVWP), achieves high-precision dispensing (better than ±0.5 nL or ±1.6% at 32 nL) of 20-40 nL droplets using a small source drop (3-10 μL) on isolated hydrophilic glass pedestals (500 μm on a side) bonded to arrays of polydimethylsiloxane conical posts. The sharp 90° edge of the glass pedestal pins the solid-liquid-vapor triple contact line (TCL), averting the wetting of the glass sidewalls while the fluid is prevented from receding from the edge. This edge creates a sufficiently large energy barrier such that microliter water droplets can be poised on the glass pedestals, exhibiting contact angles greater >150°. This approach relieves the stringent mechanical alignment tolerances required for conventional dispensing techniques, shifting the control of dispensed volume to the area circumscribed by the glass edge. The effects of glass surface chemistry and dispense velocity on droplet volume were studied using optical microscopy and high-speed video. Functionalization of the glass pedestal surface enabled the selective adsorption of specific peptides and proteins from synthetic and natural biomolecule mixtures, such as venom. We further demonstrate how the nVWP dispensing platform can be used for a variety of assays, including sensitive detection of proteins and peptides by fluorescence

  6. Study of systematics for the SOX experiment

    Energy Technology Data Exchange (ETDEWEB)

    Neumair, Birgit [Technische Univ. Muenchen, Garching bei Muenchen (Germany); Collaboration: BOREXINO-Collaboration

    2016-07-01

    In the last years, several neutrino oscillation experiments reported results not compatible within the 3-neutrino model, which hint at the existence of light sterile neutrinos. To test this hypothesis, the SOX (Short distance neutrino Oscillations in BoreXino) experiment will search for oscillations from active to sterile neutrinos by placing radioactive electron (anti-)neutrino sources underneath the Borexino detector. Oscillations will be observed via a reduction of the detected interaction rate of the electron(anti-)neutrinos and an oscillatory pattern as a function of the neutrino energy and travelled distance. The talk gives an overview of the experiment with the focus on the systematics and their impact on the sensitivity for a 100kCi {sup 144}Ce source.

  7. Including non-public data and studies in systematic reviews and systematic maps.

    Science.gov (United States)

    Haddaway, Neal R; Collins, Alexandra M; Coughlin, Deborah; Kohl, Christian

    2017-02-01

    Systematic reviews and maps should be based on the best available evidence, and reviewers should make all reasonable efforts to source and include potentially relevant studies. However, reviewers may not be able to consider all existing evidence, since some data and studies may not be publicly available. Including non-public studies in reviews provides a valuable opportunity to increase systematic review/map comprehensiveness, potentially mitigating negative impacts of publication bias. Studies may be non-public for many reasons: some may still be in the process of being published (publication can take a long time); some may not be published due to author/publisher restrictions; publication bias may make it difficult to publish non-significant or negative results. Here, we consider what forms these non-public studies may take and the implications of including them in systematic reviews and maps. Reviewers should carefully consider the advantages and disadvantages of including non-public studies, weighing risks of bias against benefits of increased comprehensiveness. As with all systematic reviews and maps, reviewers must be transparent about methods used to obtain data and avoid risks of bias in their synthesis. We make tentative suggestions for reviewers in situations where non-public data may be present in an evidence base.

  8. High-Precision Image Aided Inertial Navigation with Known Features: Observability Analysis and Performance Evaluation

    Science.gov (United States)

    Jiang, Weiping; Wang, Li; Niu, Xiaoji; Zhang, Quan; Zhang, Hui; Tang, Min; Hu, Xiangyun

    2014-01-01

    A high-precision image-aided inertial navigation system (INS) is proposed as an alternative to the carrier-phase-based differential Global Navigation Satellite Systems (CDGNSSs) when satellite-based navigation systems are unavailable. In this paper, the image/INS integrated algorithm is modeled by a tightly-coupled iterative extended Kalman filter (IEKF). Tightly-coupled integration ensures that the integrated system is reliable, even if few known feature points (i.e., less than three) are observed in the images. A new global observability analysis of this tightly-coupled integration is presented to guarantee that the system is observable under the necessary conditions. The analysis conclusions were verified by simulations and field tests. The field tests also indicate that high-precision position (centimeter-level) and attitude (half-degree-level)-integrated solutions can be achieved in a global reference. PMID:25330046

  9. High-Precision Image Aided Inertial Navigation with Known Features: Observability Analysis and Performance Evaluation

    Directory of Open Access Journals (Sweden)

    Weiping Jiang

    2014-10-01

    Full Text Available A high-precision image-aided inertial navigation system (INS is proposed as an alternative to the carrier-phase-based differential Global Navigation Satellite Systems (CDGNSSs when satellite-based navigation systems are unavailable. In this paper, the image/INS integrated algorithm is modeled by a tightly-coupled iterative extended Kalman filter (IEKF. Tightly-coupled integration ensures that the integrated system is reliable, even if few known feature points (i.e., less than three are observed in the images. A new global observability analysis of this tightly-coupled integration is presented to guarantee that the system is observable under the necessary conditions. The analysis conclusions were verified by simulations and field tests. The field tests also indicate that high-precision position (centimeter-level and attitude (half-degree-level-integrated solutions can be achieved in a global reference.

  10. HIGH-PRECISION POSITIONING AND REAL-TIME DATA PROCESSING OF UAV-SYSTEMS

    Directory of Open Access Journals (Sweden)

    M. Rieke

    2012-09-01

    Full Text Available Available micro-sized Unmanned Aerial Vehicles (UAVs in the civilian domain currently make use of common GPS receivers and do not address scenarios where high-precision positioning of the UAV is an inevitable requirement. However, for use cases such as creating orthophotos using direct georeferencing, an improved positioning needs to be developed. This article analyses the requirements for integrating Real Time Kinematic positioning into micro-sized UAVs. Additionally, it describes the data processing and synchronisation of the high-precision position data for a workflow of orthorectification of aerial imagery. Preliminary results are described for the use case of precision farming. The described approach for positioning has the potential to achieve a positional accuracy of 1–3 cm, which can be considered as adequate for direct georeferencing of aerial imagery.

  11. High-Precision Half-Wave Rectifier Circuit In Dual Phase Output Mode

    Directory of Open Access Journals (Sweden)

    Theerayut Jamjaem

    2009-12-01

    Full Text Available This paper present high-precision half-wave rectifier circuit in dual phase output mode by 0.5 μm CMOS technology, +/- 1.5 V low voltage, it has received input signal and sent output current signal, respond in high frequency. The main structure compound with CMOS inverter circuit, common source circuit, and current mirror circuit. Simulation and confirmation quality of working by PSpice program, then it able to operating at maximum frequency about 100 MHz, maximum input current range about 400 μAp-p, high precision output signal, low power dissipation, and uses a little transistor.Keywords-component; half-wave; rectifier circuit; highprecession; dual phase;

  12. MRPC-PET: A new technique for high precision time and position measurements

    Energy Technology Data Exchange (ETDEWEB)

    Doroud, K., E-mail: kdoroud@cern.ch [World Laboratory, Geneva (Switzerland); Hatzifotiadou, D. [Sezione INFN, Bologna (Italy); Li, S. [World Laboratory, Geneva (Switzerland); Williams, M.C.S. [Sezione INFN, Bologna (Italy); Zichichi, A. [Dipartimento di Fisica dell' Universita, Bologna (Italy); PH Dept, CERN, Geneva (Switzerland); Zuyeuski, R. [World Laboratory, Geneva (Switzerland)

    2011-12-21

    The purpose of this paper is to consider a new technology for medical diagnosis: the MRPC-PET. This technology allows excellent time resolution together with 2-D position information thus providing a fundamental step in this field. The principle of this method is based on the Multigap Resistive Plate Chamber (MRPC) capable of high precision time measurements. We have previously found that the route to precise timing is differential readout (this requires matching anode and cathode strips); thus crossed strip readout schemes traditionally used for 2-D readout cannot be exploited. In this paper we consider the time difference from the two ends of the strip to provide a high precision measurement along the strip; the average time gives precise timing. The MRPC-PET thus provides a basic step in the field of medical technology: excellent time resolution together with 2-D position measurement.

  13. A high-precision K-band LFMCW radar for range measurement

    Science.gov (United States)

    Jia, Yingzhuo; Chen, Xiuwei; Zou, Yongliao

    2016-11-01

    K-band LFMCW radar may be applied in high-precision range measurement, if its range resolution is made be close to mm magnitude, good performance is not only needed in hardware design, algorithm selection and optimization is but also needed. In K-band LFMCW radar system, CZT algorithm is modified according to practical radar echo signal, its simulation model is built in the System Generator tool software, the corresponding algorithm is implemented in FPGA. K-band LFMCW radar may be applied in range measurement of great volume storage tank, the outfield experiment was done according to application, experiment result shows that range measurement precision may reach mm magnitude, the system can meet the requirement of remote high-precision measurement.

  14. An Approach to Predicting Hydrocarbon with High Precision Gravity and Seismic Data

    Institute of Scientific and Technical Information of China (English)

    Wang Xiwen

    1996-01-01

    @@ There are two ways for predicting hydrocarbon reservoirs with gravity data. One is related to the indirect prediction techniques used to delineate hydrocarbon-bearing structures with dense grids of survey and high-precision gravity data. The other is direct prediction technique based on high precision gravity data, which is used to measure negative anomalies resulted from significant density changes of porous formations when saturated with different kinds of liquid. The density change of porous formations may be as high as -0.3 × 103 to -0.1 × 103kg/m3 when saturated with oil instead of water and -0.6× 103 to -0.2 × 103 kg/m3 when saturated with gas instead of water.

  15. A High-Precision Registration Technology Based on Bundle Adjustment in Structured Light Scanning System

    Directory of Open Access Journals (Sweden)

    Jianying Yuan

    2014-01-01

    Full Text Available The multiview 3D data registration precision will decrease with the increasing number of registrations when measuring a large scale object using structured light scanning. In this paper, we propose a high-precision registration method based on multiple view geometry theory in order to solve this problem. First, a multiview network is constructed during the scanning process. The bundle adjustment method from digital close range photogrammetry is used to optimize the multiview network to obtain high-precision global control points. After that, the 3D data under each local coordinate of each scan are registered with the global control points. The method overcomes the error accumulation in the traditional registration process and reduces the time consumption of the following 3D data global optimization. The multiview 3D scan registration precision and efficiency are increased. Experiments verify the effectiveness of the proposed algorithm.

  16. CLASH-VLT : A highly precise strong lensing model of the galaxy cluster RXC J2248.7-4431 (Abell S1063) and prospects for cosmography

    NARCIS (Netherlands)

    Caminha, G. B.; Grillo, C.; Rosati, P.; Balestra, I.; Karman, W.; Lombardi, M.; Mercurio, A.; Nonino, M.; Tozzi, P.; Zitrin, A.; Biviano, A.; Girardi, M.; Koekemoer, A. M.; Melchior, P.; Meneghetti, M.; Munari, E.; Suyu, S. H.; Umetsu, K.; Annunziatella, M.; Borgani, S.; Broadhurst, T.; Caputi, K. I.; Coe, D.; Delgado-Correal, C.; Ettori, S.; Fritz, A.; Frye, B.; Gobat, R.; Maier, C.; Monna, A.; Postman, M.; Sartoris, B.; Seitz, S.; Vanzella, E.; Ziegler, B.

    2016-01-01

    Aims. We perform a comprehensive study of the total mass distribution of the galaxy cluster RXC J2248.7-4431 (z = 0.348) with a set of high precision strong lensing models, which take advantage of extensive spectroscopic information on many multiply lensed systems. In the effort to understand and qu

  17. CLASH-VLT : A highly precise strong lensing model of the galaxy cluster RXC J2248.7-4431 (Abell S1063) and prospects for cosmography

    NARCIS (Netherlands)

    Caminha, G. B.; Grillo, C.; Rosati, P.; Balestra, I.; Karman, W.; Lombardi, M.; Mercurio, A.; Nonino, M.; Tozzi, P.; Zitrin, A.; Biviano, A.; Girardi, M.; Koekemoer, A. M.; Melchior, P.; Meneghetti, M.; Munari, E.; Suyu, S. H.; Umetsu, K.; Annunziatella, M.; Borgani, S.; Broadhurst, T.; Caputi, K. I.; Coe, D.; Delgado-Correal, C.; Ettori, S.; Fritz, A.; Frye, B.; Gobat, R.; Maier, C.; Monna, A.; Postman, M.; Sartoris, B.; Seitz, S.; Vanzella, E.; Ziegler, B.

    2016-01-01

    Aims. We perform a comprehensive study of the total mass distribution of the galaxy cluster RXC J2248.7-4431 (z = 0.348) with a set of high precision strong lensing models, which take advantage of extensive spectroscopic information on many multiply lensed systems. In the effort to understand and qu

  18. Research on One High Precision Megnetic Heading System Based on on-line Estimation and Correction of Remnant Devia- tion with Neural Network

    Institute of Scientific and Technical Information of China (English)

    Xu,Guanlei; Ge,Dehong; Ji,Chunsheng

    2003-01-01

    This paper presented one high precision megneticheading system,and use neural network to correct the remnantdeviation of compass.This system can study on-line and be tak-en into practice directly,which not only realize the automation ofcorrection of deviation of compass and improve the effficiency,butalso raise the precision of this megnetic heading system.

  19. Technological Considerations and Constraints in the Manufacture of High Precision Ball and Roller Bearings

    Directory of Open Access Journals (Sweden)

    Prof.S.Rajendiran,

    2015-12-01

    Full Text Available Rolling element bearings for application in Aircraft systems are to be manufactured to higher accuracy levels. Various technology details like raw material, processing stages and facilities such as machining, heat treatment, grinding, super finishing, assembly and inspection are to be considered for manufacture. However the facilities available presently in India are inadequate to produce high precision bearings. This paper deals with the prototype manufacture of bearings for some typical applications.

  20. Multiscale Multisensor Data Fusion and Application in High Precision Marking and Cutting Robot System

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The multisensor online measure system for high precision marking and cutting robot system is designed and the data fusion method is introduced, which combines augment state multiscale process with extend Kalman filter. The technology measuring the three-dimensional deforming information of profiled bars is applied. The experimental result shows that applying the multisensor data fusion technology can enhance the measure precision and the reliability of measure system.

  1. VizieR Online Data Catalog: High-precision abundances for stars with planets (Ramirez+, 2014)

    Science.gov (United States)

    Ramirez, I.; Melendez, J.; Asplund, M.

    2013-11-01

    High-precision stellar parameters and chemical abundances are presented for 111 stars; 52 of them are late-F type dwarfs and 59 are metal-rich solar analogs. The atomic linelist employed in the derivation of chemical abundances is also given. This linelist includes hyperfine structure parameters for some species. The stars' isochrone masses and ages are also reported, along with estimates of chromospheric activity. (5 data files).

  2. FOTOMCAp: a new quasi-automatic code for high-precision photometry

    CERN Document Server

    Petrucci, Romina

    2016-01-01

    The search for Earth-like planets using the transit technique has encouraged the development of strategies to obtain light curves with increasingly precision. In this context we developed the FOTOMCAp program. This is an IRAF quasi-automatic code which employs the aperture correction method and allows to obtain high-precision light curves. In this contribution we describe how this code works and show the results obtained for planetary transits light curves.

  3. Development of a monoenergetic ultraslow antiproton beam source for high-precision investigation

    Directory of Open Access Journals (Sweden)

    N. Kuroda

    2012-02-01

    Full Text Available The ASACUSA collaboration developed an ultraslow antiproton beam source, monoenergetic ultraslow antiproton source for high-precision investigation (MUSASHI, consisting of an electromagnetic trap with a liquid He free superconducting solenoid and a low energy antiproton beam transport line. The MUSASHI was capable of trapping and cooling more than 1×10^{7} antiprotons and extracting them as an ultraslow antiproton beam with energy of 150–250 eV.

  4. FOTOMCAp: a new quasi-automatic code for high-precision photometry

    Science.gov (United States)

    Petrucci, R.; Jofré, J. E.

    2016-08-01

    The search for Earth-like planets using the transit technique has encouraged the development of strategies to obtain light curves with increasing precision. In this context we developed the fotomcap program. This is an iraf quasi-automatic code which employs the aperture correction method and allows to obtain high-precision light curves. In this contribution we describe how this code works and show the results obtained for planetary transits light curves.

  5. Computer Vision Approach for Low Cost, High Precision Measurement of Grapevine Trunk Diameter in Outdoor Conditions

    OpenAIRE

    Pérez, Diego Sebastián; Bromberg, Facundo; Antivilo, Francisco Gonzalez

    2014-01-01

    Trunk diameter is a variable of agricultural interest, used mainly in the prediction of fruit trees production. It is correlated with leaf area and biomass of trees, and consequently gives a good estimate of the potential production of the plants. This work presents a low cost, high precision method for the measurement of trunk diameter of grapevines based on Computer Vision techniques. Several methods based on Computer Vision and other techniques are introduced in the literature. These metho...

  6. High Precision Topographic Mapping at Chang'E-3 Landing Site with Multi-Source Data

    Science.gov (United States)

    Liu, Y.; Liu, B.; Xu, B.; Liu, Z.; Di, K.; Zhou, J.

    2014-04-01

    Chang'e-3 (CE-3) is the first lander and rover of China following the success of Chang'e-1 and Chang'e-2 (CE-2) orbiters. High precision topographic mapping can provide detailed terrain information to ensure the safety of the rover as well as to support scientific investigations. In this research, multi-source data are co-registered into a uniform geographic framework for high precision topographic mapping at the CE-3 landing site. CE-2 CCD images with 7 m- and 1.5 m- resolutions are registered using selfcalibration bundle adjustment method with ground control points (GCPs) selected from LRO WAC mosaic map and LOLA DTM. The trajectory of CE-3 descent images are recovered using self-calibration free net bundle adjustment, and then the topographic data is rectified by absolute orientation with GCPs selected from the adjusted CE-2 DEM and DOM. Finally, these topographic data are integrated into the same geographic framework for unified, multi-scale, high precision mapping of the CE-3 landing site. Key technologies and the mapping products of this research have been used to support the surface operations of CE-3 mission.

  7. Design and Characterization of a High-Precision Digital Electromagnetic Actuator with Four Discrete Positions

    Directory of Open Access Journals (Sweden)

    Laurent Petit

    2015-10-01

    Full Text Available A high-precision planar digital electromagnetic actuator with two displacement directions and four discrete positions is presented in this paper. The four discrete positions are located at each corner of a square cavity where a mobile permanent magnet moves thanks to Lorentz forces generated when a driving current passes through two orthogonal wires placed below the cavity. Four fixed permanent magnets are placed around the cavity in order to ensure high-precision magnetic holding of the mobile magnet at each discrete position. An analytical model of the actuator is presented and used to characterize its properties (switching time, energy consumption, and displaceable mass. Based on this model, an experimental prototype has been developed and then characterized. Comparisons between experimental and simulated results are carried out and show good agreement. The positioning repeatability errors have also been characterized according to the input signal in order to qualify the digital behavior of this high-precision actuator. Finally, an application of this digital actuator as a linear conveyor is presented and experimentally tested.

  8. High-precision comparison of the antiproton-to-proton charge-to-mass ratio

    CERN Document Server

    Ulmer, S; Mooser, A; Franke, K; Nagahama, H; Schneider, G; Higuchi, T; Van Gorp, S; Blaum, K; Matsuda, Y; Quint, W; Walz, J; Yamazaki, Y

    2015-01-01

    Invariance under the charge, parity, time-reversal (CPT) transformation$^{1}$ is one of the fundamental symmetries of the standard model of particle physics. This CPT invariance implies that the fundamental properties of antiparticles and their matter-conjugates are identical, apart from signs. There is a deep link between CPT invariance and Lorentz symmetry—that is, the laws of nature seem to be invariant under the symmetry transformation of spacetime—although it is model dependent$^{2}$. A number of high-precision CPT and Lorentz invariance tests—using a co-magnetometer, a torsion pendulum and a maser, among others—have been performed$^{3}$, but only a few direct high-precision CPT tests that compare the fundamental properties of matter and antimatter are available$^{4, 5, 6, 7, 8}$. Here we report high-precision cyclotron frequency comparisons of a single antiproton and a negatively charged hydrogen ion (H$^−$) carried out in a Penning trap system. From 13,000 frequency measurements we compare th...

  9. Super high precision 200 ppi liquid crystal display series; Chokoseido 200 ppi ekisho display series

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    In mobile equipment, in demand is a high precision liquid crystal display (LCD) having the power of expression equivalent to printed materials like magazines because of the necessity of displaying a large amount of information on a easily potable small screen. In addition, with the spread and high-quality image of digital still cameras, it is strongly desired to display photographed digital image data in high quality. Toshiba Corp., by low temperature polysilicone (p-Si) technology, commercialized the liquid crystal display series of 200 ppi (pixels per inch) precision dealing with the rise of the high-precision high-image quality LCD market. The super high precision of 200 ppi enables the display of smooth beautiful animation comparable to printed sheets of magazines and photographs. The display series are suitable for the display of various information services such as electronic books and electronic photo-viewers including internet. The screen sizes lined up are No. 4 type VGA (640x480 pixels) of a small pocket notebook size and No. 6.3 type XGA (1,024x768 pixels) of a paperback size, with a larger screen to be furthered. (translated by NEDO)

  10. Concept of modular flexure-based mechanisms for ultra-high precision robot design

    Directory of Open Access Journals (Sweden)

    M. Richard

    2011-05-01

    Full Text Available This paper introduces a new concept of modular flexure-based mechanisms to design industrial ultra-high precision robots, which aims at significantly reducing both the complexity of their design and their development time. This modular concept can be considered as a robotic Lego, where a finite number of building bricks is used to quickly build a high-precision robot. The core of the concept is the transformation of a 3-D design problem into several 2-D ones, which are simpler and well-mastered. This paper will first briefly present the theoretical bases of this methodology and the requirements of both types of building bricks: the active and the passive bricks. The section dedicated to the design of the active bricks will detail the current research directions, mainly the maximisation of the strokes and the development of an actuation sub-brick. As for the passive bricks, some examples will be presented, and a discussion regarding the establishment of a mechanical solution catalogue will conclude the section. Last, this modular concept will be illustrated with a practical example, consisting in the design of a 5-degree of freedom ultra-high precision robot.

  11. Design and algorithm research of high precision airborne infrared touch screen

    Science.gov (United States)

    Zhang, Xiao-Bing; Wang, Shuang-Jie; Fu, Yan; Chen, Zhao-Quan

    2016-10-01

    There are shortcomings of low precision, touch shaking, and sharp decrease of touch precision when emitting and receiving tubes are failure in the infrared touch screen. A high precision positioning algorithm based on extended axis is proposed to solve these problems. First, the unimpeded state of the beam between emitting and receiving tubes is recorded as 0, while the impeded state is recorded as 1. Then, the method of oblique scan is used, in which the light of one emitting tube is used for five receiving tubes. The impeded information of all emitting and receiving tubes is collected as matrix. Finally, according to the method of arithmetic average, the position of the touch object is calculated. The extended axis positioning algorithm is characteristic of high precision in case of failure of individual infrared tube and affects slightly the precision. The experimental result shows that the 90% display area of the touch error is less than 0.25D, where D is the distance between adjacent emitting tubes. The conclusion is gained that the algorithm based on extended axis has advantages of high precision, little impact when individual infrared tube is failure, and using easily.

  12. A Novel Gravity Compensation Method for High Precision Free-INS Based on "Extreme Learning Machine".

    Science.gov (United States)

    Zhou, Xiao; Yang, Gongliu; Cai, Qingzhong; Wang, Jing

    2016-11-29

    In recent years, with the emergency of high precision inertial sensors (accelerometers and gyros), gravity compensation has become a major source influencing the navigation accuracy in inertial navigation systems (INS), especially for high-precision INS. This paper presents preliminary results concerning the effect of gravity disturbance on INS. Meanwhile, this paper proposes a novel gravity compensation method for high-precision INS, which estimates the gravity disturbance on the track using the extreme learning machine (ELM) method based on measured gravity data on the geoid and processes the gravity disturbance to the height where INS has an upward continuation, then compensates the obtained gravity disturbance into the error equations of INS to restrain the INS error propagation. The estimation accuracy of the gravity disturbance data is verified by numerical tests. The root mean square error (RMSE) of the ELM estimation method can be improved by 23% and 44% compared with the bilinear interpolation method in plain and mountain areas, respectively. To further validate the proposed gravity compensation method, field experiments with an experimental vehicle were carried out in two regions. Test 1 was carried out in a plain area and Test 2 in a mountain area. The field experiment results also prove that the proposed gravity compensation method can significantly improve the positioning accuracy. During the 2-h field experiments, the positioning accuracy can be improved by 13% and 29% respectively, in Tests 1 and 2, when the navigation scheme is compensated by the proposed gravity compensation method.

  13. The ASTROID Simulator Software Package: Realistic Modelling of High-Precision High-Cadence Space-Based Imaging

    CERN Document Server

    Marcos-Arenal, P; De Ridder, J; Huygen, R; Aerts, C

    2014-01-01

    The preparation of a space-mission that carries out any kind of imaging to detect high-precision low-amplitude variability of its targets requires a robust model for the expected performance of its instruments. This model cannot be derived from simple addition of noise properties due to the complex interaction between the various noise sources. While it is not feasible to build and test a prototype of the imaging device on-ground, realistic numerical simulations in the form of an end-to-end simulator can be used to model the noise propagation in the observations. These simulations not only allow studying the performance of the instrument, its noise source response and its data quality, but also the instrument design verification for different types of configurations, the observing strategy and the scientific feasibility of an observing proposal. In this way, a complete description and assessment of the objectives to expect from the mission can be derived. We present a high-precision simulation software packag...

  14. A lane-level LBS system for vehicle network with high-precision BDS/GPS positioning.

    Science.gov (United States)

    Guo, Chi; Guo, Wenfei; Cao, Guangyi; Dong, Hongbo

    2015-01-01

    In recent years, research on vehicle network location service has begun to focus on its intelligence and precision. The accuracy of space-time information has become a core factor for vehicle network systems in a mobile environment. However, difficulties persist in vehicle satellite positioning since deficiencies in the provision of high-quality space-time references greatly limit the development and application of vehicle networks. In this paper, we propose a high-precision-based vehicle network location service to solve this problem. The major components of this study include the following: (1) application of wide-area precise positioning technology to the vehicle network system. An adaptive correction message broadcast protocol is designed to satisfy the requirements for large-scale target precise positioning in the mobile Internet environment; (2) development of a concurrence service system with a flexible virtual expansion architecture to guarantee reliable data interaction between vehicles and the background; (3) verification of the positioning precision and service quality in the urban environment. Based on this high-precision positioning service platform, a lane-level location service is designed to solve a typical traffic safety problem.

  15. Using text mining for study identification in systematic reviews: a systematic review of current approaches.

    Science.gov (United States)

    O'Mara-Eves, Alison; Thomas, James; McNaught, John; Miwa, Makoto; Ananiadou, Sophia

    2015-01-14

    The large and growing number of published studies, and their increasing rate of publication, makes the task of identifying relevant studies in an unbiased way for inclusion in systematic reviews both complex and time consuming. Text mining has been offered as a potential solution: through automating some of the screening process, reviewer time can be saved. The evidence base around the use of text mining for screening has not yet been pulled together systematically; this systematic review fills that research gap. Focusing mainly on non-technical issues, the review aims to increase awareness of the potential of these technologies and promote further collaborative research between the computer science and systematic review communities. Five research questions led our review: what is the state of the evidence base; how has workload reduction been evaluated; what are the purposes of semi-automation and how effective are they; how have key contextual problems of applying text mining to the systematic review field been addressed; and what challenges to implementation have emerged? We answered these questions using standard systematic review methods: systematic and exhaustive searching, quality-assured data extraction and a narrative synthesis to synthesise findings. The evidence base is active and diverse; there is almost no replication between studies or collaboration between research teams and, whilst it is difficult to establish any overall conclusions about best approaches, it is clear that efficiencies and reductions in workload are potentially achievable. On the whole, most suggested that a saving in workload of between 30% and 70% might be possible, though sometimes the saving in workload is accompanied by the loss of 5% of relevant studies (i.e. a 95% recall). Using text mining to prioritise the order in which items are screened should be considered safe and ready for use in 'live' reviews. The use of text mining as a 'second screener' may also be used cautiously

  16. High precision measurement of the {eta} meson mass at COSY-ANKE

    Energy Technology Data Exchange (ETDEWEB)

    Goslawski, Paul

    2013-07-01

    Previous measurements of the {eta} meson mass performed at different experimental facilities resulted in very precise data but differ by up to more than eight standard deviations, i.e., 0.5 MeV/c. Interestingly, the difference seems to be dependent on the measuring method: two missing mass experiments, which produce the {eta} meson in the {sup 3}He{eta} final state, deviate from the recent invariant mass ones. In order to clarify this ambiguous situation a high precision mass measurement was realised at the COSY-ANKE facility. Therefore, a set of deuteron laboratory beam momenta and their associated {sup 3}He centre-of-mass momenta was measured in the dp{yields}{sup 3}HeX reaction near the {eta} production threshold. The {eta} meson was identified by the missing mass peak, whereas its mass was extracted by fixing the production threshold. The individual beam momenta were determined with a relative precision of 3 x 10{sup -5} for values just above 3 GeV/c by using a polarised deuteron beam and inducing an artificial depolarising spin resonance occurring at a well-defined frequency. The final state momenta in the two-body reaction dp{yields}{sup 3}He{eta} were investigated in detail by studying the size of the {sup 3}He momentum sphere with the forward detection system of the ANKE spectrometer. Final alignment and momentum calibration of the spectrometer was achieved by a comprehensive study of the {sup 3}He final state momenta as a function of the centre-of-mass angles, taking advantage of the full geometrical acceptance. The value obtained for the mass at COSY-ANKE m{sub {eta}}=(547.873{+-}0.005{sub stat.}{+-}0.027{sub syst.}) MeV/c{sup 2} is therefore worldwide the most precise one. This mass value is contrary to earlier missing mass experiments but it is consistent and competitive with recent invariant mass measurements, in which the meson was detected through its decay products.

  17. High-precision comparison of the antiproton-to-proton charge-to-mass ratio

    Science.gov (United States)

    Ulmer, S.; Smorra, C.; Mooser, A.; Franke, K.; Nagahama, H.; Schneider, G.; Higuchi, T.; van Gorp, S.; Blaum, K.; Matsuda, Y.; Quint, W.; Walz, J.; Yamazaki, Y.

    2015-08-01

    Invariance under the charge, parity, time-reversal (CPT) transformation is one of the fundamental symmetries of the standard model of particle physics. This CPT invariance implies that the fundamental properties of antiparticles and their matter-conjugates are identical, apart from signs. There is a deep link between CPT invariance and Lorentz symmetry--that is, the laws of nature seem to be invariant under the symmetry transformation of spacetime--although it is model dependent. A number of high-precision CPT and Lorentz invariance tests--using a co-magnetometer, a torsion pendulum and a maser, among others--have been performed, but only a few direct high-precision CPT tests that compare the fundamental properties of matter and antimatter are available. Here we report high-precision cyclotron frequency comparisons of a single antiproton and a negatively charged hydrogen ion (H-) carried out in a Penning trap system. From 13,000 frequency measurements we compare the charge-to-mass ratio for the antiproton to that for the proton and obtain . The measurements were performed at cyclotron frequencies of 29.6 megahertz, so our result shows that the CPT theorem holds at the atto-electronvolt scale. Our precision of 69 parts per trillion exceeds the energy resolution of previous antiproton-to-proton mass comparisons as well as the respective figure of merit of the standard model extension by a factor of four. In addition, we give a limit on sidereal variations in the measured ratio of <720 parts per trillion. By following the arguments of ref. 11, our result can be interpreted as a stringent test of the weak equivalence principle of general relativity using baryonic antimatter, and it sets a new limit on the gravitational anomaly parameter of < 8.7 × 10-7.

  18. Proceedings, High-Precision $\\alpha_s$ Measurements from LHC to FCC-ee

    Energy Technology Data Exchange (ETDEWEB)

    d' Enterria, David [CERN; Skands, Peter Z. [Monash U.

    2015-01-01

    This document provides a writeup of all contributions to the workshop on "High precision measurements of $\\alpha_s$: From LHC to FCC-ee" held at CERN, Oct. 12--13, 2015. The workshop explored in depth the latest developments on the determination of the QCD coupling $\\alpha_s$ from 15 methods where high precision measurements are (or will be) available. Those include low-energy observables: (i) lattice QCD, (ii) pion decay factor, (iii) quarkonia and (iv) $\\tau$ decays, (v) soft parton-to-hadron fragmentation functions, as well as high-energy observables: (vi) global fits of parton distribution functions, (vii) hard parton-to-hadron fragmentation functions, (viii) jets in $e^\\pm$p DIS and $\\gamma$-p photoproduction, (ix) photon structure function in $\\gamma$-$\\gamma$, (x) event shapes and (xi) jet cross sections in $e^+e^-$ collisions, (xii) W boson and (xiii) Z boson decays, and (xiv) jets and (xv) top-quark cross sections in proton-(anti)proton collisions. The current status of the theoretical and experimental uncertainties associated to each extraction method, the improvements expected from LHC data in the coming years, and future perspectives achievable in $e^+e^-$ collisions at the Future Circular Collider (FCC-ee) with $\\cal{O}$(1--100 ab$^{-1}$) integrated luminosities yielding 10$^{12}$ Z bosons and jets, and 10$^{8}$ W bosons and $\\tau$ leptons, are thoroughly reviewed. The current uncertainty of the (preliminary) 2015 strong coupling world-average value, $\\alpha_s(m_Z)$ = 0.1177 $\\pm$ 0.0013, is about 1\\%. Some participants believed this may be reduced by a factor of three in the near future by including novel high-precision observables, although this opinion was not universally shared. At the FCC-ee facility, a factor of ten reduction in the $\\alpha_s$ uncertainty should be possible, mostly thanks to the huge Z and W data samples available.

  19. Gamification in Education: A Systematic Mapping Study

    Science.gov (United States)

    Dicheva, Darina; Dichev, Christo; Agre, Gennady; Angelova, Galia

    2015-01-01

    While gamification is gaining ground in business, marketing, corporate management, and wellness initiatives, its application in education is still an emerging trend. This article presents a study of the published empirical research on the application of gamification to education. The study is limited to papers that discuss explicitly the effects…

  20. Gamification in Education: A Systematic Mapping Study

    Science.gov (United States)

    Dicheva, Darina; Dichev, Christo; Agre, Gennady; Angelova, Galia

    2015-01-01

    While gamification is gaining ground in business, marketing, corporate management, and wellness initiatives, its application in education is still an emerging trend. This article presents a study of the published empirical research on the application of gamification to education. The study is limited to papers that discuss explicitly the effects…

  1. Microplasma patterning of bonded microchannels using high-precision "injected" electrodes.

    Science.gov (United States)

    Priest, Craig; Gruner, Philipp J; Szili, Endre J; Al-Bataineh, Sameer A; Bradley, James W; Ralston, John; Steele, David A; Short, Robert D

    2011-02-07

    A rapid, high-precision method for localised plasma-treatment of bonded PDMS microchannels is demonstrated. Patterned electrodes were prepared by injection of molten gallium into preformed microchannel guides. The electrode guides were prepared without any additional fabrication steps compared to conventional microchannel fabrication. Alignment of the "injected" electrodes is precisely controlled by the photomask design, rather than positioning accuracy of alignment tools. Surface modification is detected using a fluorescent dye (Rhodamine B), revealing a well-defined micropattern with regions less than 100 µm along the length of the microchannel.

  2. High Precision Prediction of Rolling Force Based on Fuzzy and Nerve Method for Cold Tandem Mill

    Institute of Scientific and Technical Information of China (English)

    JIA Chun-yu; SHAN Xiu-ying; NIU Zhao-ping

    2008-01-01

    The rolling force model for cold tandem mill was put forward by using the Elman dynamic recursive network method, based on the actual measured data. Furthermore, a good assumption is put forward, which brings a full universe of discourse self-adjusting factor fuzzy control, closed-loop adjusting, based on error feedback and expertise into a rolling force prediction model, to modify prediction outputs and improve prediction precision and robustness. The simulated results indicate that the method is highly effective and the prediction precision is better than that of the traditional method. Predicted relative error is less than ±4%, so the prediction is high precise for the cold tandem mill.

  3. [Physiological and hygienic characteristic of high-precision manufacturing operations in microelectronics].

    Science.gov (United States)

    Kirillov, V F; Mironov, A I; Gadakchan, K A; Mekhova, M M; Spiridonova, V S

    2010-01-01

    It was shown that workers performing high-precision manufacturing operations in microelectronic industry undergo severe visual, nervous and emotional stress combined with significant locomotor load, air deionization and deozonation, bacterial contamination, and UV deficit at their workplaces. These working conditions promote development of negative changes in the visual analyzer, nervous and emotional disorders, disturbances of systemic and regional hemodynamics. Also impaired is the functional state of the upper limb neuromuscular apparatus, central nervous and cardiovascular systems. The proposed certified complex of organizational, sanitary, hygienic, physiological, ergonomic, therapeutic and preventive measures has positive influence on the working capacity of employees in microelectronic industry.

  4. Precision mechatronics based on high-precision measuring and positioning systems and machines

    Science.gov (United States)

    Jäger, Gerd; Manske, Eberhard; Hausotte, Tino; Mastylo, Rostyslav; Dorozhovets, Natalja; Hofmann, Norbert

    2007-06-01

    Precision mechatronics is defined in the paper as the science and engineering of a new generation of high precision systems and machines. Nanomeasuring and nanopositioning engineering represents important fields of precision mechatronics. The nanometrology is described as the today's limit of the precision engineering. The problem, how to design nanopositioning machines with uncertainties as small as possible will be discussed. The integration of several optical and tactile nanoprobes makes the 3D-nanopositioning machine suitable for various tasks, such as long range scanning probe microscopy, mask and wafer inspection, nanotribology, nanoindentation, free form surface measurement as well as measurement of microoptics, precision molds, microgears, ring gauges and small holes.

  5. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Fasanella, Giuseppe

    2016-01-01

    The CMS Electromagnetic Calorimeter utilizes scintillating lead tungstate crystals, with avalanche photodiodes (APD) as photo-detectors in the barrel part. 1224 HV channels bias groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  6. High precision, low disturbance calibration system for the CMS Barrel Electromagnetic Calorimeter High Voltage apparatus

    Science.gov (United States)

    Fasanella, G.

    2017-01-01

    The CMS Electromagnetic Calorimeter utilizes scintillation lead tungstate crystals, with avalanche photodiodes (APD) as photo-detectors in the barrel part. 1224 HV channels bias groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3%/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  7. A High-Precision Forecasting Model and Its Constructing Method for Vein-Type Gold Deposits

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A high-precision forecasting and prospecting model incorporating the “field theory-field structure analysis-field simulation”, a temporal and spatial structural framework reflecting local extremely fine structures, is established to make an effective extraction and an integrated analysis of multivariate forecasting information. This model can best show not only the coupling between metallogenic anomalous structure, mineralized structure and information structure, but also the extraction, optimization, matching and summarization of key forecasting information. The technological keys to this model are the fine structural analysis of geological and geophysical and geochemical anomalous fields and metallogenic fields, and the establishment of occurrence patterns for the spatial location of orebodies.

  8. High-precision efficiency calibration of a high-purity co-axial germanium detector

    Energy Technology Data Exchange (ETDEWEB)

    Blank, B., E-mail: blank@cenbg.in2p3.fr [Centre d' Etudes Nucléaires de Bordeaux Gradignan, UMR 5797, CNRS/IN2P3, Université de Bordeaux, Chemin du Solarium, BP 120, 33175 Gradignan Cedex (France); Souin, J.; Ascher, P.; Audirac, L.; Canchel, G.; Gerbaux, M.; Grévy, S.; Giovinazzo, J.; Guérin, H.; Nieto, T. Kurtukian; Matea, I. [Centre d' Etudes Nucléaires de Bordeaux Gradignan, UMR 5797, CNRS/IN2P3, Université de Bordeaux, Chemin du Solarium, BP 120, 33175 Gradignan Cedex (France); Bouzomita, H.; Delahaye, P.; Grinyer, G.F.; Thomas, J.C. [Grand Accélérateur National d' Ions Lourds, CEA/DSM, CNRS/IN2P3, Bvd Henri Becquerel, BP 55027, F-14076 CAEN Cedex 5 (France)

    2015-03-11

    A high-purity co-axial germanium detector has been calibrated in efficiency to a precision of about 0.15% over a wide energy range. High-precision scans of the detector crystal and γ-ray source measurements have been compared to Monte-Carlo simulations to adjust the dimensions of a detector model. For this purpose, standard calibration sources and short-lived online sources have been used. The resulting efficiency calibration reaches the precision needed e.g. for branching ratio measurements of super-allowed β decays for tests of the weak-interaction standard model.

  9. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Marzocchi, Badder

    2017-01-01

    The CMS Electromagnetic Calorimeter is made of scintillating lead tungstate crystals, using avalanche photodiodes (APD) as photo-detectors in the barrel part. The high voltage system, consisting of 1224 channels, biases groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  10. Stellar Astrophysics Using Ultra-High Precision CCD Time Series Photometry

    Science.gov (United States)

    Howell, S.; Everett, M.; Huber, M.; Ciardi, D.; van Belle, G.

    2001-05-01

    Using time-series CCD photometry and a wide-field imager, we have extended the techniques of differential photometry to provide robust photometric precisions for each star over the entire field of view. Reaching photometric precisions of 2 milli-magnitudes, we produced high cadence light curves for over 12,000 stars at mid- and high galactic latitude. The fraction of stars seen to be variable is higher than the canonical wisdom, being 10-14 will present the details of our techniques, sample light curves, methods to access the data, and a summary of astrophysical uses of such high precision data.

  11. On the recovery of gravity anomalies from high precision altimeter data

    Science.gov (United States)

    Lelgemann, D.

    1976-01-01

    A model for the recovery of gravity anomalies from high precision altimeter data is derived which consists of small correction terms to the inverse Stokes' formula. The influence of unknown sea surface topography in the case of meandering currents such as the Gulf Stream is discussed. A formula was derived in order to estimate the accuracy of the gravity anomalies from the known accuracy of the altimeter data. It is shown that for the case of known harmonic coefficients of lower order the range of integration in Stokes inverse formula can be reduced very much.

  12. Proposed design for high precision refractive index sensor using integrated planar lightwave circuit

    Science.gov (United States)

    Maru, Koichi; Fujii, Yusaku; Zhang, Shulian; Hou, Wenmei

    2009-07-01

    A high precision and compact refractive index sensor is proposed. The combination of coarse measurement utilizing the change of the angle of refraction and fine measurement utilizing the phase change is newly proposed to measure absolute refractive index precisely. The proposed method does not need expensive optical measurement equipment such as an optical spectrum analyzer. The integrated planar lightwave circuit (PLC) technology enables us to obtain a compact sensor that is preferable for the practical use. The principle, design, and some configurations for precise refractive index measurement are described.

  13. Investigation of the proton-neutron interaction by high-precision nuclear mass measurements

    CERN Multimedia

    Savreux, R P; Akkus, B

    2007-01-01

    We propose to measure the atomic masses of a series of short-lived nuclides, including $^{70}$Ni, $^{122-130}$Cd, $^{134}$Sn, $^{138,140}$Xe, $^{207-210}$Hg, and $^{223-225}$Rn, that contribute to the investigation of the proton-neutron interaction and its role in nuclear structure. The high-precision mass measurements are planned for the Penning trap mass spectrometer ISOLTRAP that reaches the required precision of 10 keV in the nuclear mass determination.

  14. High precision measurement of the associated strangeness production in proton proton interactions

    CERN Document Server

    :,; Borodina, E; Clement, H; Doroshkevich, E; Dzhygadlo, R; Ehrhardt, K; Eyrich, W; Gast, W; Gillitzer, A; Grzonka, D; Hauenstein, F; Klaja, P; Kober, L; Kilian, K; Krapp, M; Mertens, M; Moskal, P; Ritman, J; Roderburg, E; Röder, M; Schroeder, W; Sefzick, T; Smyrski, J; Wintz, P; Wüstner, P

    2016-01-01

    A new high precision measurement of the reaction pp -> pK+Lambda at a beam momentum of 2.95 GeV/c with more than 200,000 analyzed events allows a detailed analysis of differential observables and their inter-dependencies. Correlations of the angular distributions with momenta are examined. The invariant mass distributions are compared for different regions in the Dalitz plots. The cusp structure at the N Sigma threshold is described with the Flatt\\'e formalism and its variation in the Dalitz plot is analyzed.

  15. High-precision measurement of the associated strangeness production in proton-proton interactions

    Energy Technology Data Exchange (ETDEWEB)

    Jowzaee, S. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Jagellonian University, Institute of Physics, Cracow (Poland); Borodina, E.; Dzhygadlo, R.; Gast, W.; Gillitzer, A.; Grzonka, D.; Kilian, K.; Mertens, M.; Roderburg, E.; Roeder, M.; Sefzick, T.; Wintz, P. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Clement, H. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Erlangen (Germany); University of Tuebingen, Kepler Center for Astro and Particle Physics, Tuebingen (Germany); Doroshkevich, E.; Ehrhardt, K. [Physikalisches Institut der Universitaet Tuebingen, Tuebingen (Germany); University of Tuebingen, Kepler Center for Astro and Particle Physics, Tuebingen (Germany); Eyrich, W.; Kober, L.; Krapp, M. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Erlangen (Germany); Hauenstein, F.; Klaja, P. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Erlangen (Germany); Moskal, P.; Smyrski, J. [Jagellonian University, Institute of Physics, Cracow (Poland); Ritman, J. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Forces and Matter Experiments (JARA-FAME), Juelich Aachen Research Allianz, Juelich (Germany); Ruhr-Universitaet Bochum, Experimentalphysik I, Bochum (Germany); Schroeder, W. [Forschungszentrum Juelich, Corporate Development, Juelich (Germany); Wuestner, P. [Elektronik und Analytik, Zentralinstitut fuer Engineering, Juelich (Germany); Collaboration: The COSY-TOF Collaboration

    2016-01-15

    A new high-precision measurement of the reaction pp → pK{sup +}Λ at a beam momentum of 2.95 GeV/c with more than 200 000 analyzed events allows a detailed analysis of differential observables and their inter-dependencies. Correlations of the angular distributions with momenta are examined. The invariant mass distributions are compared for different regions in the Dalitz plots. The cusp structure at the NΣ threshold is described with the Flatte formalism and its variation in the Dalitz plot is analyzed. (orig.)

  16. High-precision measurement of the associated strangeness production in proton-proton interactions

    Science.gov (United States)

    Jowzaee, S.; Borodina, E.; Clement, H.; Doroshkevich, E.; Dzhygadlo, R.; Ehrhardt, K.; Eyrich, W.; Gast, W.; Gillitzer, A.; Grzonka, D.; Hauenstein, F.; Klaja, P.; Kober, L.; Kilian, K.; Krapp, M.; Mertens, M.; Moskal, P.; Ritman, J.; Roderburg, E.; Röder, M.; Schroeder, W.; Sefzick, T.; Smyrski, J.; Wintz, P.; Wüstner, P.

    2016-01-01

    A new high-precision measurement of the reaction pp→ pK+Λ at a beam momentum of 2.95 GeV/ c with more than 200 000 analyzed events allows a detailed analysis of differential observables and their inter-dependencies. Correlations of the angular distributions with momenta are examined. The invariant mass distributions are compared for different regions in the Dalitz plots. The cusp structure at the NΣ threshold is described with the Flatté formalism and its variation in the Dalitz plot is analyzed.

  17. Mechanical optimisation of a high-precision fast wire scanner at CERN

    CERN Document Server

    Samuelsson, Sebastian; Veness, Raymond

    Wire scanners are instruments used to measure the transverse beam prole in particle accelerators by passing a thin wire through the particle beam. To avoid the issues of vacuum leakage through the bellows and wire failure related to current designs of wire scanners, a new concept for a wire scanner has been developed at CERN. This design has all moving parts inside the beam vacuum and has a nominal wire scanning speed of 20 m/s. The demands on the design associated with this together with the high precision requirements create a need for\

  18. High precision measurement of the differential $W$ and $Z$ boson production cross sections

    CERN Document Server

    Sommer, Philip; The ATLAS collaboration

    2017-01-01

    Measurements of the Drell-Yan production of $W$ and $Z/\\gamma^*$ bosons at the LHC provide a benchmark of our understanding of perturbative QCD and probe the proton structure in a unique way. The ATLAS collaboration has performed new high precision measurements at center-of-mass energies of 7 TeV. The measurements are performed for $W^+$, $W^-$ and $Z/\\gamma^*$ bosons integrated and as a function of the boson or lepton rapidity and the $Z/\\gamma^*$ mass. Unprecedented precision is reached and strong constraints on Parton Distribution functions, in particular the strange density are found. Slides for DIS 2017 in Birmingham

  19. Enabling ultra high precision on hard steels using surface defect machining

    OpenAIRE

    2014-01-01

    This paper is an extension to an idea coined during the 13th EUSPEN Conference (P6.23) named "surface defect machining" (SDM). The objective of this work was to demonstrate how a conventional CNC turret lathe can be used to obtain ultra high precision machined surface finish on hard steels without recourse to a sophisticated ultra precision machine tool. An AISI 4340 hard steel (69 HRC) workpiece was machined using a CBN cutting tool with and without SDM. Post-machining measurements by a Form...

  20. A faster, high precision algorithm for calculating symmetric and asymmetric $M_{T2}$

    CERN Document Server

    Lally, Colin H

    2015-01-01

    A new algorithm for calculating the stransverse mass, $M_{T2}$, in either symmetric or asymmetric situations has been developed which exhibits good stability, high precision and quadratic convergence for the majority of the $M_{T2}$ parameter space, leading to up to a factor of ten increase in speed compared to other $M_{T2}$ calculators of comparable precision. This document describes and validates the methodology used by the algorithm, and provides comparisons both in terms of accuracy and speed with other existing implementations.

  1. Nd-142/Nd-144 in bulk planetary reservoirs, the problem of incomplete mixing of interstellar components and significance of very high precision Nd-145/Nd-144 measurements

    Science.gov (United States)

    Harper, C. L., Jr.; Jacobsen, S. B.

    1993-01-01

    Apart from the challenge of very high precision Nd-142/Nd-144 ratio measurement, accurate applications of the coupled Sm-(146,147)-Nd-(142,143) systematics in planetary differentiation studies require very precise knowledge of the present-day (post-Sm-146 decay) Nd-142/Nd-144 ratios of bulk planetary objects (BP). The coupled systematics yield model ages for the time of formation of Sm/Nd-fractionated reservoirs by differentiation of Sm/Nd-unfractionated bulk planetary reservoirs. Estimates of (Nd-142/Nd-144)(sub BP) and (Nd-143/Nd-144)(sub BP) therefore provide the critical baseline relative to which these model ages are referenced. In the Sm-147-Nd-143 systematics, Nd-143/Nd-144 variations are mostly large; therefore, small variations in initial Nd-143/Nd-144 ratios generally can be ignored. However, in the case of Sm-146-Nd-142, the range of Nd-142/Nd-144 divergence for differentiated planetary reservoirs is much smaller. Consequently Sm-(146,147)-Nd-(142,143) model ages are sensitive to small variations in bulk planetary Nd-142/Nd-144 (both present-day and initial). One major unanswered question is whether or not Nd shelf standards (CIT Nd beta/Ames metal, La Jolla, NASA-JSC/Ames metal) have Nd-142/Nd-144 identical to the bulk Earth or otherwise might record some degree of radiogenic evolution in an early-fractionated reservoir. Our discussions of earth Earth differentiation based on Nd-142/Nd-144 in Isua and Acasta samples have employed a working assumption: (Nd-142/Nd-144)(sub Nd beta) = (Nd-142/Nd-144)(sub Bulk Earth). This requires experimental justification and is apparently contradicted by chondrite Nd-142/Nd-144 measurements, which have been interpreted to indicate: (Nd-142/Nd-144)(sub JSC/Ames metal) = ((Nd-142/Nd-144)(sub CHUR) = 35 plus or minus 8 ppm). At present, interpretations of the early Earth and Moon hinge largely on this issue. Because Ba in bulk chondrite samples exhibit similar magnitude nuclear anomalies, attributable to incomplete mixing

  2. The Social Relations Model in Family Studies: A Systematic Review

    Science.gov (United States)

    Eichelsheim, Veroni I.; Dekovic, Maja; Buist, Kirsten L.; Cook, William L.

    2009-01-01

    The Social Relations Model (SRM) allows for examination of family relations on three different levels: the individual level (actor and partner effects), the dyadic level (relationship effects), and the family level (family effect). The aim of this study was to present a systematic review of SRM family studies and identify general patterns in the…

  3. Study of systematic errors in the luminosity measurement

    Energy Technology Data Exchange (ETDEWEB)

    Arima, Tatsumi [Tsukuba Univ., Ibaraki (Japan). Inst. of Applied Physics

    1993-04-01

    The experimental systematic error in the barrel region was estimated to be 0.44 %. This value is derived considering the systematic uncertainties from the dominant sources but does not include uncertainties which are being studied. In the end cap region, the study of shower behavior and clustering effect is under way in order to determine the angular resolution at the low angle edge of the Liquid Argon Calorimeter. We also expect that the systematic error in this region will be less than 1 %. The technical precision of theoretical uncertainty is better than 0.1 % comparing the Tobimatsu-Shimizu program and BABAMC modified by ALEPH. To estimate the physical uncertainty we will use the ALIBABA [9] which includes O({alpha}{sup 2}) QED correction in leading-log approximation. (J.P.N.).

  4. Development and Preliminary Testing of a High Precision Long Stroke Slit Change Mechanism for the SPICE Instrument

    Science.gov (United States)

    Paciotti, Gabriel; Humphries, Martin; Rottmeier, Fabrice; Blecha, Luc

    2014-01-01

    In the frame of ESA's Solar Orbiter scientific mission, Almatech has been selected to design, develop and test the Slit Change Mechanism of the SPICE (SPectral Imaging of the Coronal Environment) instrument. In order to guaranty optical cleanliness level while fulfilling stringent positioning accuracies and repeatability requirements for slit positioning in the optical path of the instrument, a linear guiding system based on a double flexible blade arrangement has been selected. The four different slits to be used for the SPICE instrument resulted in a total stroke of 16.5 mm in this linear slit changer arrangement. The combination of long stroke and high precision positioning requirements has been identified as the main design challenge to be validated through breadboard models testing. This paper presents the development of SPICE's Slit Change Mechanism (SCM) and the two-step validation tests successfully performed on breadboard models of its flexible blade support system. The validation test results have demonstrated the full adequacy of the flexible blade guiding system implemented in SPICE's Slit Change Mechanism in a stand-alone configuration. Further breadboard test results, studying the influence of the compliant connection to the SCM linear actuator on an enhanced flexible guiding system design have shown significant enhancements in the positioning accuracy and repeatability of the selected flexible guiding system. Preliminary evaluation of the linear actuator design, including a detailed tolerance analyses, has shown the suitability of this satellite roller screw based mechanism for the actuation of the tested flexible guiding system and compliant connection. The presented development and preliminary testing of the high-precision long-stroke Slit Change Mechanism for the SPICE Instrument are considered fully successful such that future tests considering the full Slit Change Mechanism can be performed, with the gained confidence, directly on a

  5. Astronomical calibration of 40Ar/39Ar reference minerals using high-precision, multi-collector (ARGUSVI) mass spectrometry

    Science.gov (United States)

    Phillips, D.; Matchan, E. L.; Honda, M.; Kuiper, K. F.

    2017-01-01

    The new generation of multi-collector mass spectrometers (e.g. ARGUSVI) permit ultra-high precision (1%) in 40K decay constants and the ages of natural reference minerals that form the basis of the technique. For example, reported ages for widely used 40Ar/39Ar reference materials, such as the ca. 28 Ma Fish Canyon Tuff sanidine (FCTs) and the ca. 1.2 Ma Alder Creek Rhyolite sanidine (ACRs), vary by >1%. Recent attempts to independently calibrate these reference minerals have focused on K-Ar analyses of the same minerals and inter-comparisons with astronomically tuned tephras in sedimentary sequences and U-Pb zircon ages from volcanic rocks. Most of these studies used older generation (effectively single-collector) mass spectrometers that employed peak-jumping analytical methods to acquire 40Ar/39Ar data. In this study, we reassess the inter-calibration and ages of commonly used 40Ar/39Ar reference minerals Fish Canyon Tuff sanidine (FCTs), Alder Creek Rhyolite sanidine (ACRs) and Mount Dromedary biotite (MD2b; equivalent to GA-1550 biotite), relative to the astronomically tuned age of A1 Tephra sanidine (A1Ts), Faneromeni section, Crete (Rivera et al., 2011), using a multi-collector ARGUSVI mass spectrometer. These analyses confirm the exceptional precision capability (0.1% in the 40Ar/39Ar ages of reference minerals without consideration of recoil artefacts, thus limiting the benefits of high precision multi-collector analyses. Significant improvement to the accuracy of the 40Ar/39Ar method (<0.1%) will require further inter-laboratory 40Ar/39Ar studies utilizing multi-collector mass spectrometry, additional constraints on recoil 39ArK loss from reference minerals, further resolution of discrepancies between astronomically tuned sedimentary successions and refinement of the 238U/206Pb zircon age cross-calibration approach.

  6. High-precision, high-throughput stability determinations facilitated by robotics and a semiautomated titrating fluorometer.

    Science.gov (United States)

    Edgell, Marshall Hall; Sims, Dorothy A; Pielak, Gary J; Yi, Fang

    2003-06-24

    The use of statistical modeling to test hypotheses concerning the determinants of protein structure requires stability data (e.g., the free energy of denaturation in H(2)O, DeltaG(HOH)) from hundreds of protein mutants. Fluorescence-monitored chemical denaturation provides a convenient method for high-precision, high-throughput DeltaG(HOH) determination. For eglin c we find that a throughput of about 20 min per protein can be attained in a two-channel semiautomated titrating fluorometer. We find also that the use of robotics for protein purification and preparation of the solutions for chemical denaturation gives highly precise DeltaG(HOH) values in which the standard deviation of values from multiple preparations (+/-0.051 kcal/mol) differs very little from multiple measurements from a single preparation (+/-0.040 kcal/mol). Since the variance introduced into model fitting by DeltaG(HOH) increases as the square of measurement error, there is a premium on precision. In fact, the fraction of stability behavior explicable by otherwise perfect models goes from 98% to only 50% over the error range commonly reported for chemical denaturation measurements (0.1-0.6 kcal/mol). We have found that the precision of chemical denaturation DeltaG(HOH) measurements depends most heavily on the precision of the instrument used, followed by protein purity and the capacity to precisely prepare the solutions used for titrations.

  7. FPGA-based High-precision Measurement Algorithm for the Ultrasonic Echo Time of Flight

    Institute of Scientific and Technical Information of China (English)

    Bo-xiong WANG; Jin ZHANG

    2010-01-01

    Based on the evaluation of advantages and disadvantages of high-precision digital time interval measuring algorithms, and combined with the principle of the typical time-difference ultrasonic flow measurement,the requirements far the measurement of echo time of flight put forward by the ultrasonic flow measurement are an-alyzed.A new high-precision time interval measurement algorithm is presented, which combines the pulse counting method with the phase delay interpolation. The pulse counting method is used to ensure a large dynamic measuring range, and a double-edge triggering counter is designed to improve the accuracy and reduce the counting quantiza-tion error.The phase delay interpolation is used to reduce the quanti-zation error of pulse counting for further improving the time measure-ment resolution.Test data show that the system for the measurement of the ultrasonic echo time of flight based on this algorithm and im-plemented on an Field Programmable Gate Array(FPGA) needs a rel-atively short time for measurement,and has a measurement error of less than 105 ps.

  8. Remote and high precision step height measurement with an optical fiber multiplexing interferometric system

    Science.gov (United States)

    Wang, Yunzhi; Xie, Fang; Ma, Sen; Chen, Liang

    2015-03-01

    An optical fiber multiplexing low coherence and high coherence interferometric system, which includes a Fizeau interferometer as the sensing element and a Michelson interferometer as the demodulating element, is designed for remote and high precision step height measurement. The Fizeau interferometer is placed in the remote field for sensing the measurand, while the Michelson interferometer which works in both modes of low coherence interferometry and high coherence interferometry is employed for demodulating the measurand. The range of the step height is determined by the low coherence interferometry and the value of it is measured precisely by the high coherence interferometry. High precision has been obtained by searching precisely the peak of the low coherence interferogram symmetrically from two sides of the low coherence interferogram and stabilizing the Michelson interferometer with a feedback loop. The maximum step height that could be measured is 6 mm while the measurement resolution is less than 1 nm. The standard deviation of 10 times measurement results of a step height of 1 mm configurated with two gauge blocks is 0.5 nm.

  9. An optical fiber multiplexing interferometric system for measuring remote and high precision step height

    Science.gov (United States)

    Wang, Yunzhi; Xie, Fang; Ma, Sen; Chen, Liang

    2015-02-01

    In this paper, an optical fiber multiplexing interferometric system including a Fizeau interferometer and a Michelson interferometer is designed for remote and high precision step height measurement. The Fizeau interferometer which is inserted in the remote sensing field is used for sensing the measurand, while the Michelson interferometer which is stabilized by a feedback loop works in both modes of low coherence interferometry and high coherence interferometry to demodulate the measurand. The range of the step height is determined by the low coherence interferometry and the value of it is measured precisely by the high coherence interferometry. High precision has been obtained by using the symmetrical peak-searching method to address the peak of the low coherence interferogram precisely and stabilizing the Michelson interferometer with a feedback loop. The maximum step height that could be measured is 6 mm while the measurement resolution is less than 1 nm. The standard deviation of 10 times measurement results of a step height of 1 mm configurated with two gauge blocks is 0.5 nm.

  10. High precise control method for a new type of piezoelectric electro-hydraulic servo valve

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A new type of piezoelectric electro-hydraulic servo valve system was proposed. And then multilayer piezoelectric actuator based on new piezoelectric ceramic material was used as the electricity-machine converter of the proposed piezoelectric electro-hydraulic servo valve. The proposed piezoelectric electro-hydraulic servo valve has ascendant performance compared with conventional ones. But the system is of high nonlinearity and uncertainty, it cannot achieve favorable control performance by conventional control method. To develop an efficient way to control piezoelectric electro-hydraulic servo valve system, a high-precise fuzzy control method with hysteresis nonlinear model in feedforward loop was proposed. The control method is separated into two parts: a feedforward loop with Preisach hysteresis nonlinear model and a feedback loop with high-precise fuzzy control. Experimental results show that the hysteresis loop and the maximum output hysteresis by the PID control method are 4.22%and 2.11 μm, respectively; the hysteresis loop and the maximum output hysteresis by the proposed control method respectively are 0.74% and 0.37 μm, respectively; the maximum tracking error by the PID control method for sine wave reference signal is about 5.02%, the maximum tracking error by the proposed control method for sine wave reference signal is about 0.85%.

  11. High-precision Thickness Setting Models for Titanium Alloy Plate Cold Rolling without Tension

    Institute of Scientific and Technical Information of China (English)

    WANG Xiaochen; YANG Quan; HE Fei; SUN Youzhao; XIAO Huifang

    2015-01-01

    Due to its highly favorable physical and chemical properties, titanium and titanium alloy are widely used in a variety of industries. Because of the low output of a single batch, plate cold rolling without tension is the most common rolling production method for titanium alloy. This method is lack of on-line thickness closed-loop control, with carefully thickness setting models for precision. A set of high-precision thickness setting models are proposed to suit the production method. Because of frequent variations in rolling specification, a model structural for the combination of analytical models and statistical models is adopted to replace the traditional self-learning method. The deformation resistance and friction factor, the primary factors which affect model precision, are considered as the objectives of statistical modeling. Firstly, the coefficient fitting of deformation resistance analytical model based on over-determined equations set is adopted. Additionally, a support vector machine(SVM) is applied to the modeling of the deformation resistance and friction factor. The setting models are applied to a 1450 plate-coiling mill for titanium alloy plate rolling, and then thickness precision is found consistently to be within 3%, exceeding the precision of traditional setting models with a self-learning method based on a large number of stable rolling data. Excellent application performance is obtained. The proposed research provides a set of high-precision thickness setting models which are well adapted to the characteristics of titanium alloy plate cold rolling without tension.

  12. The honeycomb strip chamber: A two coordinate and high precision muon detector

    Energy Technology Data Exchange (ETDEWEB)

    Tolsma, H.P.T.

    1996-04-19

    This thesis describes the construction and performance of the Honeycomb Strip Chamber (HSC). The HSC offers several advantages with respect to classical drift chambers and drift tubes. The main features of the HSC are: -The detector offers the possibility of simultaneous readout of two orthogonal coordinates with approximately the same precision. - The HSC technology is optimised for mass production. This means that the design is modular (monolayers) and automisation of most of the production steps is possible (folding and welding machines). - The technology is flexible. The cell diameter can easily be changed from a few millimetres to at least 20 mm by changing the parameters in the computer programme of the folding machine. The number of monolayers per station can be chosen freely to the demands of the experiment. -The honeycomb structure gives the detector stiffness and makes it self supporting. This makes the technology a very transparent one in terms of radiation length which is important to prevent multiple scattering of high energetic muons. - The dimensions of the detector are defined by high precision templates. Those templates constrain for example the overall tolerance on the wire positions to 20 {mu}m rms. Reproduction of the high precision assembly of the detector is thus guaranteed. (orig.).

  13. A high-precision instrument for analyzing nonlinear dynamic behavior of bearing cage

    Science.gov (United States)

    Yang, Z.; Chen, H.; Yu, T.; Li, B.

    2016-08-01

    The high-precision ball bearing is fundamental to the performance of complex mechanical systems. As the speed increases, the cage behavior becomes a key factor in influencing the bearing performance, especially life and reliability. This paper develops a high-precision instrument for analyzing nonlinear dynamic behavior of the bearing cage. The trajectory of the rotational center and non-repetitive run-out (NRRO) of the cage are used to evaluate the instability of cage motion. This instrument applied an aerostatic spindle to support and spin test the bearing to decrease the influence of system error. Then, a high-speed camera is used to capture images when the bearing works at high speeds. A 3D trajectory tracking software tema Motion is used to track the spot which marked the cage surface. Finally, by developing the matlab program, a Lissajous' figure was used to evaluate the nonlinear dynamic behavior of the cage with different speeds. The trajectory of rotational center and NRRO of the cage with various speeds are analyzed. The results can be used to predict the initial failure and optimize cage structural parameters. In addition, the repeatability precision of instrument is also validated. In the future, the motorized spindle will be applied to increase testing speed and image processing algorithms will be developed to analyze the trajectory of the cage.

  14. High precision locations of long-period events at La Fossa Crater (Vulcano Island, Italy

    Directory of Open Access Journals (Sweden)

    Salvatore Rapisarda

    2009-06-01

    Full Text Available Since the last eruption in 1888-90, the volcanic activity on Vulcano Island (Aeolian Archipelago, Italy has been limited to fumarolic degassing. Fumaroles are mainly concentred at the active cone of La Fossa in the northern sector of the island and are periodically characterized by increases in temperature as well as in the amount of both CO2 and He. Seismic background activity at Vulcano is dominated by micro-seismicity originating at shallow depth (<1-1.5 km under La Fossa cone. This seismicity is related to geothermal system processes and comprises long period (LP events. LPs are generally considered as the resonance of a fluid-filled volume in response to a trigger. We analyzed LP events recorded during an anomalous degassing period (August-October 2006 applying a high precision technique to define the shape of the trigger source. Absolute and high precision locations suggest that LP events recorded at Vulcano during 2006 were produced by a shallow focal zone ca. 200 m long, 40 m wide and N30-40E oriented. Their occurrence is linked to magmatic fluid inputs that by modifying the hydrothermal system cause excitation of a fluid-filled cavity.

  15. Optimization design about gimbal structure of high-precision autonomous celestial navigation tracking mirror system

    Science.gov (United States)

    Huang, Wei; Yang, Xiao-xu; Han, Jun-feng; Wei, Yu; Zhang, Jing; Xie, Mei-lin; Yue, Peng

    2016-01-01

    High precision tracking platform of celestial navigation with control mirror servo structure form, to solve the disadvantages of big volume and rotational inertia, slow response speed, and so on. It improved the stability and tracking accuracy of platform. Due to optical sensor and mirror are installed on the middle-gimbal, stiffness and resonant frequency requirement for high. Based on the application of finite element modality analysis theory, doing Research on dynamic characteristics of the middle-gimbal, and ANSYS was used for the finite element dynamic emulator analysis. According to the result of the computer to find out the weak links of the structure, and Put forward improvement suggestions and reanalysis. The lowest resonant frequency of optimization middle-gimbal avoid the bandwidth of the platform servo mechanism, and much higher than the disturbance frequency of carrier aircraft, and reduces mechanical resonance of the framework. Reaching provides a theoretical basis for the whole machine structure optimization design of high-precision of autonomous Celestial navigation tracking mirror system.

  16. High-precision thickness setting models for titanium alloy plate cold rolling without tension

    Science.gov (United States)

    Wang, Xiaochen; Yang, Quan; He, Fei; Sun, Youzhao; Xiao, Huifang

    2015-03-01

    Due to its highly favorable physical and chemical properties, titanium and titanium alloy are widely used in a variety of industries. Because of the low output of a single batch, plate cold rolling without tension is the most common rolling production method for titanium alloy. This method is lack of on-line thickness closed-loop control, with carefully thickness setting models for precision. A set of high-precision thickness setting models are proposed to suit the production method. Because of frequent variations in rolling specification, a model structural for the combination of analytical models and statistical models is adopted to replace the traditional self-learning method. The deformation resistance and friction factor, the primary factors which affect model precision, are considered as the objectives of statistical modeling. Firstly, the coefficient fitting of deformation resistance analytical model based on over-determined equations set is adopted. Additionally, a support vector machine(SVM) is applied to the modeling of the deformation resistance and friction factor. The setting models are applied to a 1450 plate-coiling mill for titanium alloy plate rolling, and then thickness precision is found consistently to be within 3%, exceeding the precision of traditional setting models with a self-learning method based on a large number of stable rolling data. Excellent application performance is obtained. The proposed research provides a set of high-precision thickness setting models which are well adapted to the characteristics of titanium alloy plate cold rolling without tension.

  17. A high-precision instrument for analyzing nonlinear dynamic behavior of bearing cage.

    Science.gov (United States)

    Yang, Z; Chen, H; Yu, T; Li, B

    2016-08-01

    The high-precision ball bearing is fundamental to the performance of complex mechanical systems. As the speed increases, the cage behavior becomes a key factor in influencing the bearing performance, especially life and reliability. This paper develops a high-precision instrument for analyzing nonlinear dynamic behavior of the bearing cage. The trajectory of the rotational center and non-repetitive run-out (NRRO) of the cage are used to evaluate the instability of cage motion. This instrument applied an aerostatic spindle to support and spin test the bearing to decrease the influence of system error. Then, a high-speed camera is used to capture images when the bearing works at high speeds. A 3D trajectory tracking software tema Motion is used to track the spot which marked the cage surface. Finally, by developing the matlab program, a Lissajous' figure was used to evaluate the nonlinear dynamic behavior of the cage with different speeds. The trajectory of rotational center and NRRO of the cage with various speeds are analyzed. The results can be used to predict the initial failure and optimize cage structural parameters. In addition, the repeatability precision of instrument is also validated. In the future, the motorized spindle will be applied to increase testing speed and image processing algorithms will be developed to analyze the trajectory of the cage.

  18. [High-precision 3D morphology measurement by digital gatling method based on structured light].

    Science.gov (United States)

    Luo, Gang-Yin; Tang, Yu-Guo; Qiao, Pei-Yu; Wang, Bi-Dou; Jia, Zan-Dong; Xu, Zhong

    2012-09-01

    In order to measure the microscopic 3D morphology of the objects with high-precision, a 3D texture measurement system of digital gatling based on structured light was designed, which can calculate the 3D height information with the analytic phase method. First, the authors collected sixteen equal step phase images by the four-step equal step method, and calculated their main value by dividing them into four groups. Then, the authors found the average as the final phase main value. The pretreatment on the fringe was done by the adaptive Wiener filter and wavelet multi-threshold method to eliminate the various effects of noise, projector distortion and CCD camera distortion. Besides, gradient-oriented phase unwrapping algorithm based on multifrequency was introduced to avoid phase discontinuity point in the course phase unwrapping, and it was proven to be effective and stable. Experiments showed that the system's 3D resolution was 2.75 microm, and the high degree accuracy was better than 0.5 microm, when the system was running with the fringe parameter p0 = 22.7 mm(-1). In addition, the system has many advantages such as fast measuring, simple operation and non-contact, which can meet the need of the high precision measurement requirements for the microscopic 3D morphology.

  19. The high-precision videometrics methods to determining absolute vertical benchmark

    Science.gov (United States)

    Liu, Jinbo; Zhu, Zhaokun

    2013-01-01

    The mobile measurement equipment plays an important role in engineering measurement tasks and its measuring device is fixed with the vehicle platform. Therefore, how to correct the measured error in time that caused by swayed platform is a basic problem. Videometrics has its inherent advantages in solving this problem. First of all, videometrics technology is non-contact measurement, which has no effect on the target's structural characteristics and motion characteristics. Secondly, videometrics technology has high precision especially for surface targets and linear targets in the field of view. Thirdly, videometrics technology has the advantages of automatic, real-time and dynamic. This paper is mainly for mobile theodolite.etc that works under the environment of absolute vertical benchmark and proposed two high-precision methods to determine vertical benchmark: Direct-Extracting, which is based on the intersection of plats under the help of two cameras; Benchmark-Transformation, which gets the vertical benchmark by reconstructing the level-plat. Two methods both have the precision of under 10 seconds by digital simulation and physical experiments. The methods proposed by this paper have significance both on the theory and application.

  20. Workshop on High-precision $\\alpha_s$ measurements from LHC to FCC-ee

    CERN Document Server

    S. Alekhin; d'Enterria, David; A. Banfi; S. Bethke; J. Blümlein; K.G. Chetyrkin; D. d’Enterria; G. Dissertori; X. Garcia i Tormo; A. H. Hoang; M. Klasen; T. Klijnsma; S. Kluth; J.-L. Kneur; B.A. Kniehl; D. W. Kolodrubetz; J. Kühn; P. Mackenzie; B. Malaescu; V. Mateu; L. Mihaila; S. Moch; K. Mönig; R. Pérez-Ramos; A. Pich; J. Pires; K. Rabbertz; G. P. Salam; F. Sannino; J. Soto i Riera; M. Srebre; I. W. Stewart

    2015-01-01

    This document provides a writeup of all contributions to the workshop on "High precision measurements of $\\alpha_s$: From LHC to FCC-ee" held at CERN, Oct. 12--13, 2015. The workshop explored in depth the latest developments on the determination of the QCD coupling $\\alpha_s$ from 15 methods where high precision measurements are (or will be) available. Those include low-energy observables: (i) lattice QCD, (ii) pion decay factor, (iii) quarkonia and (iv) $\\tau$ decays, (v) soft parton-to-hadron fragmentation functions, as well as high-energy observables: (vi) global fits of parton distribution functions, (vii) hard parton-to-hadron fragmentation functions, (viii) jets in $e^\\pm$p DIS and $\\gamma$-p photoproduction, (ix) photon structure function in $\\gamma$-$\\gamma$, (x) event shapes and (xi) jet cross sections in $e^+e^-$ collisions, (xii) W boson and (xiii) Z boson decays, and (xiv) jets and (xv) top-quark cross sections in proton-(anti)proton collisions. The current status of the theoretical and experiment...

  1. High-Precision Superallowed Fermi β Decay Measurements at TRIUMF-ISAC

    Science.gov (United States)

    Svensson, C. E.

    2016-09-01

    High-precision measurements of the ft -values for superallowed Fermi β decays between nuclear isobaric analogue states provide demanding tests of the electroweak Standard Model, including confirmation of the Conserved Vector Current hypothesis at the level of 1 . 2 ×10-4 , the most stringent limits on weak scalar currents, and the most precise determination of the Vud element of the CKM quark-mixing matrix. The Isotope Separator and Accelerator (ISAC) facility at TRIUMF produces high-quality beams of several of the superallowed emitters with world-record intensities and hosts a suite of state-of-the-art spectrometers for the measurement of superallowed half-lives, branching ratios, QEC values, and charge-radii. Recent highlights from the superallowed program at ISAC, including high-precision half-life measurements for the light superallowed emitters 10C, 14O, 18Ne, and 26mAl and branching-ratio measurements for the heavy superallowed emitters 62Ga and 74Rb will be presented. The impact of these measurements on tests of the Standard Model, and future developments in the superallowed program at ISAC with the new high-efficiency GRIFFIN γ - ray spectrometer, will be discussed. Research supported by the Natural Sciences and Engineering Research Council of Canada, the Canada Foundation for Innovation, and the Canada Research Chairs Program. TRIUMF receives federal funding via the National Research Council of Canada.

  2. Design and development of a high-precision, high-payload telescope dual-drive system

    Science.gov (United States)

    Worthington, Michael S.; Beets, Timothy A.; Beno, Joseph H.; Mock, Jason R.; Murphy, Brian T.; South, Brian J.; Good, John M.

    2010-07-01

    A high precision, dual drive system has been designed and developed for the Wide Field Upgrade to the Hobby-Eberly Telescope* at McDonald Observatory in support of the Hobby-Eberly Telescope Dark Energy Experiment‡. Analysis, design and controls details will be of interest to designers of large scale, high precision robotic motion devices. The drive system positions the 19,000 kg star tracker to a precision of less than 5 microns along its 4-meter travel. While positioning requirements remain essentially equal to the existing HET, tracker mass increases by a factor greater than 5. The 10.5-meter long tracker is driven at each end by planetary roller screws, each having two distinct drive sources dictated by the desired operation: one slowly rotates the screw when tracking celestial objects and the second rotates the nut for rapid displacements. Key results of the roller screw rotordynamics analysis are presented. A description of the complex bearing arrangement providing required degrees of freedom as well as the impact of a detailed Failure Modes and Effects Analysis addressing necessary safety systems is also presented. Finite element analysis results demonstrate how mechanical springs increase the telescope's natural frequency response by 22 percent. The critical analysis and resulting design is provided.

  3. Extending and refining the mass surface around $^{208}$Pb by high-precision Penning-trap mass spectrometry with ISOLTRAP

    CERN Multimedia

    Herfurth, F; Stora, T; Blaum, K; Beck, D; Kowalska, M; Schwarz, S; Stanja, J; Herlert, A J; Yamaguchi, T

    We propose high-precision mass spectrometry of nuclides around the doubly magic $^{208}$Pb. On the neutron-rich side, we aim to extend the knowledge of Fr, At, Hg, and Au masses to study the robustness of the N = 126 shell closure and to provide mass data necessary for modeling the rapid-neutron-capture process. On the proton-rich side, we aim at high-resolution mass spectrometry of selected Au, At, and Fr isotopes to verify the predicted existence of very low-lying isomeric states. The proposal will make use of newly-available laser-ionization schemes for Au and At. Finally, the recently implemented multi-reflection time-of-flight mass separator for auxiliary isobaric purification now allows measurements which were not feasible before.

  4. High-precision mass measurements of nickel, copper, and gallium isotopes and the purported shell closure at N=40

    CERN Document Server

    Guenaut, C; Beck, D; Blaum, K; Bollen, G; Delahaye, P; Herfurth, F; Kellerbauer, A G; Kluge, H J; Libert, J; Lunney, M D; Schwarz, S; Schweikhard, L; Yazidjian, C

    2007-01-01

    High-precision mass measurements of more than thirty neutron-rich nuclides around the Z=28 closed proton shell were performed with the triple-trap mass spectrometer ISOLTRAP at ISOLDE/CERN to address the question of a possible neutron shell closure at N=40. The results, for 57,60,64-69Ni (Z=28), 65-74,76Cu (Z=29), and 63-65,68-78Ga (Z=31), have a relative uncertainty of the order of 10^8. In particular, the masses of 72-74,76Cu have been measured for the first time. We analyse the resulting mass surface for signs of magicity, comparing the behavior of N=40 to that of known magic numbers and to mid-shell behavior. Contrary to nuclear spectroscopy studies, no indications of a shell or sub-shell closure are found for N=40.

  5. SPIRou: the near-infrared spectropolarimeter/high-precision velocimeter for the Canada-France-Hawaii telescope

    CERN Document Server

    Artigau, Étienne; Donati, Jean-François; Doyon, René; Delfosse, Xavier; Baratchart, Sébastien; Lacombe, Marielle; Moutou, Claire; Rabou, Patrick; Parès, Laurent P; Micheau, Yoan; Thibault, Simon; Reshetov, Vladimir A; Dubois, Bruno; Hernandez, Olivier; Vallée, Philippe; Wang, Shiang-Yu; Dolon, François; Pepe, Francesco A; Bouchy, François; Striebig, Nicolas; Hénault, François; Loop, David; Saddlemyer, Leslie; Barrick, Gregory; Vermeulen, Tom; Dupieux, Michel; Hébrard, Guillaume; Boisse, Isabelle; Martioli, Eder; Alencar, Silvia H P; Nascimento, José-Diaz do; Figueira, Pedro

    2014-01-01

    SPIRou is a near-IR \\'echelle spectropolarimeter and high-precision velocimeter under construction as a next-generation instrument for the Canada-France-Hawaii-Telescope. It is designed to cover a very wide simultaneous near-IR spectral range (0.98-2.35 {\\mu}m) at a resolving power of 73.5K, providing unpolarized and polarized spectra of low-mass stars at a radial velocity (RV) precision of 1m/s. The main science goals of SPIRou are the detection of habitable super-Earths around low-mass stars and the study of how critically magnetic fields impact star / planet formation. Following a successful final design review in Spring 2014, SPIRou is now under construction and is scheduled to see first light in late 2017. We present an overview of key aspects of SPIRou's optical and mechanical design.

  6. Characteristics of Induced and Tectonic Seismicity in Oklahoma Based on High-precision Earthquake Relocations and Focal mechanisms

    Science.gov (United States)

    Aziz Zanjani, F.; Lin, G.

    2016-12-01

    Seismic activity in Oklahoma has greatly increased since 2013, when the number of wastewater disposal wells associated with oil and gas production was significantly increased in the area. An M5.8 earthquake at about 5 km depth struck near Pawnee, Oklahoma on September 3, 2016. This earthquake is postulated to be related with the anthropogenic activity in Oklahoma. In this study, we investigate the seismic characteristics in Oklahoma by using high-precision earthquake relocations and focal mechanisms. We acquire the seismic data between January 2013 and October 2016 recorded by the local and regional (within 200 km distance from the Pawnee mainshock) seismic stations from the Incorporated Research Institutions for Seismology (IRIS). We relocate all the earthquakes by applying the source-specific station term method and a differential time relocation method based on waveform cross-correlation data. The high-precision earthquake relocation catalog is then used to perform full-waveform modeling. We use Muller's reflection method for Green's function construction and the mtinvers program for moment tensor inversion. The sensitivity of the solution to the station and component distribution is evaluated by carrying out the Jackknife resampling. These earthquake relocation and focal mechanism results will help constrain the fault orientation and the earthquake rupture length. In order to examine the static Coulomb stress change due to the 2016 Pawnee earthquake, we utilize the Coulomb 3 software in the vicinity of the mainshock and compare the aftershock pattern with the calculated stress variation. The stress change in the study area can be translated into probability of seismic failure on other parts of the designated fault.

  7. Register mark measurement errors in high-precision roll-to-roll continuous systems: The effect of register mark geometry on measurement error

    Science.gov (United States)

    Lee, Jongsu; Isto, Pekka; Jeong, Hakyung; Park, Janghoon; Lee, Dongjin; Shin, Kee-Hyun

    2016-10-01

    It is important to achieve high-precision register control in roll-to-roll continuous printing systems. Thus far, many studies on the dynamics of registers and tension and on register control techniques have identified register control as a problem of controlling and minimizing the disturbance of strain of the substrate. However, register control using printed register marks is necessary, and printing defects in creating these marks cause measurement errors. This study demonstrates by experimental verification that the measurement error is generated by the widening and agglomeration of the register mark. Furthermore, the error is shown to differ with the size and shape of the mark under identical printing conditions. The results illustrate the importance of improving the printing quality of the register mark, selecting the desired geometry for register marks with regard to printability, and utilizing an edge-detection algorithm in the control program for high-precision register control.

  8. An optical fan for light beams for high-precision optical measurements and optical switching

    CERN Document Server

    Zhou, Zhi-Yuan; Ding, Dong-Sheng; Jiang, Yun-Kun; Zhang, Wei; Shi, Shuai; Shi, Bao-Sen; Guo, Guang-Can

    2014-01-01

    The polarization and orbital angular momentum properties of light are of great importance in optical science and technology in the fields of high precision optical measurements and high capacity and high speed optical communications. Here we show, a totally new method, based on a combination of these two properties and using the thermal dispersion and electro-optical effect of birefringent crystals, the construction of a simple and robust scheme to rotate a light beam like a fan. Using a computer-based digital image processing technique, we determine the temperature and the thermal dispersion difference of the crystal with high resolution. We also use the rotation phenomenon to realize thermo-optic and electro-optic switches. The basic operating principles for measurement and switching processes are presented in detail. The methods developed here will have wide practical applicability in various fields, including remote sensing, materials science and optical communication networks.

  9. Depth Impact Control of an Electromagnetic Actuator for High Precision Engraving

    Directory of Open Access Journals (Sweden)

    E. Castillo–Castañeda

    2008-10-01

    Full Text Available This document presents both the mechanical elements and the motion control of a novel three–axis metal engraving machine. The aim of this work is to improve the conventional high resolution engraving techniques that commonly use expensive piezoelectric actuators with reduced impact depth. Also, it is presented the depth impact control in open loop for an electromagnetic actuator (solenoid. A conical tool is fixed on the mobile part of the solenoid that moves toward the work piece when the solenoid is energized. This novel machine performs micro–impacts of controlled depth on metallic flat surfaces and it can be also applied to high precision machining processes. The machine was experimentally tested on steel work pieces using scanned pictures.

  10. A High Precision Direct Integration Scheme Based on Variational Principle and Its Applications

    Directory of Open Access Journals (Sweden)

    Zhu Shuai

    2016-01-01

    Full Text Available Dynamics response of systems to impact or loading may be effectively treated by direct integration. However, it is often difficult to select the time-step of integration properly, especially in the case which the system is badly stiff. High Precision Direct integration based on variational principle is given (HPD-VP for homogeneous systems and HHPD-VP method for the nonhomogeneous systems are given. This method not only takes the advantage of variational principle formula, which is much precise and is stiff A-stable, but also can avoid the truncation error of the computer. For the large systems, especially, the systems with different frequency or the stiff systems, our methods are stable, accurate and efficient. Numerical experiments show the convergence order of the scheme derived from the variational principle, and is much precise and is effective in engineering.

  11. High-Precision Floating-Point Arithmetic in ScientificComputation

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, David H.

    2004-12-31

    At the present time, IEEE 64-bit floating-point arithmetic is sufficiently accurate for most scientific applications. However, for a rapidly growing body of important scientific computing applications, a higher level of numeric precision is required: some of these applications require roughly twice this level; others require four times; while still others require hundreds or more digits to obtain numerically meaningful results. Such calculations have been facilitated by new high-precision software packages that include high-level language translation modules to minimize the conversion effort. These activities have yielded a number of interesting new scientific results in fields as diverse as quantum theory, climate modeling and experimental mathematics, a few of which are described in this article. Such developments suggest that in the future, the numeric precision used for a scientific computation may be as important to the program design as are the algorithms and data structures.

  12. High-precision gravimetric survey in support of lunar laser ranging at Haleakala, Maui, 1976 - 1978

    Science.gov (United States)

    Schenck, B. E.; Laurila, S. H.

    1978-01-01

    The planning, observations and adjustment of high-precision gravity survey networks established on the islands of Maui and Oahu as part of the geodetic-geophysical program in support of lunar laser ranging at Haleakala, Maui, Hawaii are described. The gravity survey networks include 43 independently measured gravity differences along the gravity calibration line from Kahului Airport to the summit of Mt. Haleakala, together with some key points close to tidal gauges on Maui, and 40 gravity differences within metropolitan Honolulu. The results of the 1976-1978 survey are compared with surveys made in 1961 and in 1964-1965. All final gravity values are given in the system of the international gravity standardization net 1971 (IGSN 71); values are obtained by subtracting 14.57 mgal from the Potsdam value at the gravity base station at the Hickam Air Force Base, Honolulu.

  13. Moving Object Detection Using Scanning Camera on a High-Precision Intelligent Holder

    Directory of Open Access Journals (Sweden)

    Shuoyang Chen

    2016-10-01

    Full Text Available During the process of moving object detection in an intelligent visual surveillance system, a scenario with complex background is sure to appear. The traditional methods, such as “frame difference” and “optical flow”, may not able to deal with the problem very well. In such scenarios, we use a modified algorithm to do the background modeling work. In this paper, we use edge detection to get an edge difference image just to enhance the ability of resistance illumination variation. Then we use a “multi-block temporal-analyzing LBP (Local Binary Pattern” algorithm to do the segmentation. In the end, a connected component is used to locate the object. We also produce a hardware platform, the core of which consists of the DSP (Digital Signal Processor and FPGA (Field Programmable Gate Array platforms and the high-precision intelligent holder.

  14. A high-precision cryogenically-cooled crystal monochromator for the APS diagnostics beamline

    Energy Technology Data Exchange (ETDEWEB)

    Rotela, E.; Yang, B.; Sharma, s.; Barcikowski, A.

    2000-07-24

    A high-precision cryogenically-cooled crystal monochromator has been developed for the APS diagnostics beamline. The design permits simultaneous measurements of the particle beam size and divergence. It provides for a large rotation angle, {minus}15{degree} to 180{degree}, with a resolution of 0.0005{degree}. The roll angle of the crystal can be adjusted by up to {+-}3{degree} with a resolution of 0.0001{degree}. A vertical translational stage, with a stroke of {+-}25 mm and resolution of 8 {micro}m, is provided to enable using different parts of the same crystal or to retract the crystal from the beam path. The modular design will allow optimization of cooling schemes to minimize thermal distortions of the crystal under high heat loads.

  15. High Precision Momentum Calibration of the Magnetic Spectrometers at MAMI for Hypernuclear Binding Energy Determination

    CERN Document Server

    Margaryan, A; Achenbach, P; Ajvazyan, R; Elbakyan, H; Montgomery, R; Nakamura, S N; Pochodzalla, J; Schulz, F; Toyama, Y; Zhamkochyan, S

    2016-01-01

    We propose a new method for absolute momentum calibration of magnetic spectrometers used in nuclear physics, using the time-of-flight (TOF), differences of pairs of particles with different masses. In cases where the flight path is not known, a calibration can be determined by using the TOF differences of two pair combinations of three particles. A Cherenkov detector, read out by a radio frequency photomultiplier tube, is considered as the high-resolution and highly stable TOF detector. By means of Monte Carlo simulations it is demonstrated that the magnetic spectrometers at the MAMI electron-scattering facility can be calibrated absolutely with an accuracy $\\delta p/p\\leq 10^{-4}$, which will be crucial for high precision determination of hypernuclear masses.

  16. A Direct Comparison of Two High Precision Relative Gravity Meters at Optimal Performance

    Science.gov (United States)

    van Westrum, D.

    2015-12-01

    NGS has maintained and operated GWR Superconducting Gravimeter #024 since 1995. It has been widely considered one of the most quiet instruments from that era. It was recently upgraded with state of the art electronics and its operating parameters reoptimzied. A Micro-g LaCoste gPhoneX, installed on a high precision tilt table, was collocated with the SG at the Table Mountain Geophysical Observatory near Boulder, CO and the two instruments operated side by side for approximately two months. Results in both the frequency domain and selected time series from large seismic signals (e.g. earthquakes) will be presented, allowing for a direct comparison between the instruments in identical, ideal conditions.

  17. Integrated Alignment and Inspection Platform for High Precision Optical Continuous Images

    Directory of Open Access Journals (Sweden)

    Chuen-Horng Lin

    2014-11-01

    Full Text Available This platform is mainly intended to be used as a facility for high precision optical continuous images. Then, with a fixed pattern being selected, this platform can quickly search, with resistance to variation, the mark that corresponds to the pattern in order to achieve the alignment and inspection target. Since the pattern is a minute component with multiple shapes and unstable features, this platform can automatically acquire it through the system or select it by user. The targets searched by the mark include light, intensity, occlusion and rotation. It then, calculates the variances of light, intensity, occlusion and rotation individually with the mark under detection, search and pattern to achieve the inspection function. Therefore, combined with a quick and accurate mark detection and the search method, this platform builds an interface integrated platform that is easy to operate and user-friendly.

  18. Determination of the half-life of 213Fr with high precision

    Science.gov (United States)

    Fisichella, M.; Musumarra, A.; Farinon, F.; Nociforo, C.; Del Zoppo, A.; Figuera, P.; La Cognata, M.; Pellegriti, M. G.; Scuderi, V.; Torresi, D.; Strano, E.

    2013-07-01

    High-precision measurement of half-life and Qα value of neutral and highly charged α emitters is a major subject of investigation currently. In this framework, we recently pushed half-life measurements of neutral emitters to a precision of a few per mil. This result was achieved by using different techniques and apparatuses at Istituto Nazionale di Fisica Nucleare Laboratori Nazionali del Sud (INFN-LNS) and GSI Darmstadt. Here we report on 213Fr half-life determination [T1/2(213Fr) = 34.14±0.06 s] at INFN-LNS, detailing the measurement protocol used. Direct comparison with the accepted value in the literature shows a discrepancy of more than three sigma. We propose this new value as a reference, discussing previous experiments.

  19. ACADEMIC TRAINING: Probing nature with high precision; particle traps, laser spectroscopy and optical combs

    CERN Multimedia

    Françoise Benz

    2002-01-01

    17, 18, 19 June LECTURE SERIES from 11.00 to 12.00 hrs - Auditorium, bldg. 500 Probing nature with high precision; particle traps, laser spectroscopy and optical combs by G. GABRIELSE / Harvard University, USA Experiments with atomic energy scales probe nature and its symmetries with exquisite precision. Particle traps allow the manipulation of single charged particles for months at a time, allow the most accurate comparison of theory and experiment, and promise to allow better measurement of fundamental quantities like the fine structure constant. Ions and atoms can be probed with lasers that are phase locked to microwave frequency standards via optical combs, thus calibrating optical sources in terms of the official cesium second. A series of three lectures will illustrate what can be measured and discuss key techniques.  ACADEMIC TRAINING Françoise Benz Tel. 73127 francoise.benz@cern.ch

  20. Limiting Energy Dissipation Induces Glassy Kinetics in Single-Cell High-Precision Responses.

    Science.gov (United States)

    Das, Jayajit

    2016-03-08

    Single cells often generate precise responses by involving dissipative out-of-thermodynamic-equilibrium processes in signaling networks. The available free energy to fuel these processes could become limited depending on the metabolic state of an individual cell. How does limiting dissipation affect the kinetics of high-precision responses in single cells? I address this question in the context of a kinetic proofreading scheme used in a simple model of early-time T cell signaling. Using exact analytical calculations and numerical simulations, I show that limiting dissipation qualitatively changes the kinetics in single cells marked by emergence of slow kinetics, large cell-to-cell variations of copy numbers, temporally correlated stochastic events (dynamic facilitation), and ergodicity breaking. Thus, constraints in energy dissipation, in addition to negatively affecting ligand discrimination in T cells, can create a fundamental difficulty in determining single-cell kinetics from cell-population results. Copyright © 2016 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  1. Nonlinear analysis of cylindrical capacitive sensor used for measuring high precision spindle rotation errors

    Science.gov (United States)

    Xiang, Kui; Wang, Wen; Zhang, Min; Lu, Keqing; Fan, Zongwei; Chen, Zichen

    2015-02-01

    A novel cylindrical capacitive sensor (CCS) with differential, symmetrical and integrated structure was proposed to measure multi-degree-of-freedom rotation errors of high precision spindle simultaneously and to reduce impacts of multiple sensors installation errors on the measurement accuracy. The nonlinear relationship between the output capacitance of CCS and the radial gap was derived using the capacitance formula and was quantitatively analyzed. It was found through analysis that the thickness of curved electrode plates led to the existence of fringe effect. The influence of the fringe effect on the output capacitance was investigated through FEM simulation. It was found through analysis and simulation that the CCS could be optimized to improve the measurement accuracy.

  2. Status and Outlook of CHIP-TRAP: the Central Michigan University High Precision Penning Trap

    CERN Document Server

    Redshaw, Matthew; Hawks, Paul; Gamage, Nadeesha D; Hunt, Curtis; Kandegedara, Rathnayake M E B; Ratnayake, Ishara S; Sharp, Lance

    2015-01-01

    At Central Michigan University we are developing a high-precision Penning trap mass spectrometer (CHIP-TRAP)that will focus on measurements with long-lived radioactive isotopes. CHIP-TRAP will consist of a pair of hyperbolic precision-measurement Penning traps, and a cylindrical capture/?filter trap in a 12 T magnetic field. Ions will be produced by external ion sources, including a laser ablation source, and transported to the capture trap at low energies enabling ions of a given m=q ratio to be selected via their time-of-flight. In the capture trap, contaminant ions will be removed with a mass-selective rf dipole excitation and the ion of interest will be transported to the measurement traps. A phase-sensitive image charge detection technique will be used for simultaneous cyclotron frequency measurements on single ions in the two precision traps, resulting in a reduction in statistical uncertainty due to magnetic field fluctuations.

  3. Design and Manufacturing of a High-Precision Sun Tracking System Based on Image Processing

    Directory of Open Access Journals (Sweden)

    Kianoosh Azizi

    2013-01-01

    Full Text Available Concentration solar arrays require greater solar tracking precision than conventional photovoltaic arrays. This paper presents a high precision low cost dual axis sun tracking system based on image processing for concentration photovoltaic applications. An imaging device is designed according to the principle of pinhole imaging, making sun rays to be received on a screen through pinhole and to be a sun spot. The location of the spot is used to adjust the orientation of the solar panel. A fuzzy logic controller is developed to achieve this goal. A prototype was built, and experimental results have proven the good performance of the proposed system and low error of tracking. The operation of this system is independent of geographical location, initial calibration, and periodical regulations.

  4. High precision (14 bit), high density (octal) analog to digital converter for spectroscopy applications

    Science.gov (United States)

    Subramaniam, E. T.; Jain, Mamta; Bhowmik, R. K.; Tripon, Michel

    2008-10-01

    Nuclear and particle physics experiments with large number of detectors require signal processing and data collection strategies that call for the ability to collect large amount of data while not sacrificing the precision and accuracy of the data being collected. This paper deals with the development of a high precision pulse peak detection, analog to digital converter (ADC) module with eight independent channels in plug-in daughter card motherboard model, best suited for spectroscopy experiments. This module provides multiple channels without cross-talk and of 14 bit resolution, while maintaining high density (each daughter card has an area of just 4.2″×0.51″) and exhibiting excellent integral nonlinearity (≤±2 mV or ±0.02% full scale reading) and differential nonlinearity (≤±1%). It was designed, developed and tested, in house, and gives added advantages of cost effectiveness and ease of maintenance.

  5. High precision measurement of the topological Aharonov-Casher effect with neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Cimmino, A.; Allman, B.E.; Klein, A.G.; Kaiser, H.; Werner, S.A

    2000-02-11

    The phase shift predicted by Aharonov and Casher (AC) for a magnetic dipole diffracting around a line charge was first observed by Cimmino et al. using a neutron interferometer. A number of subsequent atom interferometry experiments have been performed to observe this effect. These experiments measured the vxE phase shift due to the magnetic field induced in the rest frame of the atom, with no indication of the topological nature of the AC interaction. We intend to perform a high precision AC experiment with neutrons to improve the accuracy of our previous results and to highlight the topological nature of the effect. Finally, we present a novel geometry to achieve a spin-dependent magnetic phase shift00.

  6. High precision measurement of the topological Aharonov-Casher effect with neutrons

    CERN Document Server

    Cimmino, A; Klein, A G; Kaiser, H; Werner, S A

    2000-01-01

    The phase shift predicted by Aharonov and Casher (AC) for a magnetic dipole diffracting around a line charge was first observed by Cimmino et al. using a neutron interferometer. A number of subsequent atom interferometry experiments have been performed to observe this effect. These experiments measured the vxE phase shift due to the magnetic field induced in the rest frame of the atom, with no indication of the topological nature of the AC interaction. We intend to perform a high precision AC experiment with neutrons to improve the accuracy of our previous results and to highlight the topological nature of the effect. Finally, we present a novel geometry to achieve a spin-dependent magnetic phase shift.

  7. High-precision masses of neutron-deficient rubidium isotopes using a Penning trap mass spectrometer

    CERN Document Server

    Kellerbauer, A G; Beck, D; Blaum, K; Bollen, G; Guénaut, C; Herfurth, F; Herlert, A; Kluge, H J; Lunney, D; Schwarz, S; Schweikhard, L; Weber, C; Yazidjian, C

    2007-01-01

    The atomic masses of the neutron-deficient radioactive rubidium isotopes $^{74-77,79,80,83}$Rb have been measured with the Penning trap mass spectrometer ISOLTRAP. Using the time-of-flight cyclotron resonance technique, relative mass uncertainties ranging from $1.6 \\times 10^{-8}$ to $5.6 \\times 10^{-8}$ were achieved. In all cases, the mass precision was significantly improved as compared with the prior Atomic-Mass Evaluation; no significant deviations from the literature values were observed. The exotic nuclide $^{74}$Rb with a half-life of only 65 ms, is the shortest-lived nuclide on which a high-precision mass measurement in a Penning trap has been carried out. The significance of these measurements for a check of the conserved-vector-current hypothesis of the weak interaction and the unitarity of the Cabibbo-Kobayashi-Maskawa matrix is discussed.

  8. High-precision soft x-ray polarimeter at Diamond Light Source.

    Science.gov (United States)

    Wang, H; Dhesi, S S; Maccherozzi, F; Cavill, S; Shepherd, E; Yuan, F; Deshmukh, R; Scott, S; van der Laan, G; Sawhney, K J S

    2011-12-01

    The development and performance of a high-precision polarimeter for the polarization analysis in the soft x-ray region is presented. This versatile, high-vacuum compatible instrument is supported on a hexapod to simplify the alignment with a resolution less than 5 μrad, and can be moved with its own independent control system easily between different beamlines and synchrotron facilities. The polarimeter can also be used for the characterization of reflection and transmission properties of optical elements. A W/B(4)C multilayer phase retarder was used to characterize the polarization state up to 1200 eV. A fast and accurate alignment procedure was developed, and complete polarization analysis of the APPLE II undulator at 712 eV has been performed.

  9. HIGHLY PRECISE AND FAST COMPUTATION OF THE CONTINUOUS SIGNAL PAR IN OFDM AND DMT SYSTEMS

    Institute of Scientific and Technical Information of China (English)

    Yu Hua; Lin Yaorong; Wei Gang

    2005-01-01

    Two procedures are developed here to compute the Peak-to-Average envelope power Ratio (PAR) of the continuous signal with N subcarriers in the Orthogonal Frequency Division Multiplexing (OFDM) and Discrete MultiTone (DMT) systems. The first one is an accurate computation method for small N, in which the peak of the Instantaneous Envelope Power Function (IEPF) is obtained by solving the roots of a polynomial, a linear sum of a set of Chebyshev polynomials of the first kind and the second kind. The second procedure, called Stepwise Refinement Algorithm (SRA), is a highly precise and fast computation method for arbitrary N by using Inverse Fast Fourier Transform (IFFT), the Chirp Z-Transform (CZT) and a newly introduced relationship between the IEPF peak and its most adjacent oversampled sample.

  10. What can we learn from high precision measurements of neutrino mixing angles?

    Indian Academy of Sciences (India)

    R N Mohapatra

    2004-12-01

    Many experiments are being planned to measure the neutrino mixing angles more precisely. In this note, the theoretical significance of a high precision measurement of these parameters is discussed. It is emphasized that they can provide crucial information about different ways to understand the origin of large atmospheric neutrino mixing and move us closer towards determining the neutrino mass matrix. They may also be able to throw light on the question of lepton–quark unification as well as the existence of any leptonic symmetries. For instance if exact ↔ symmetry in the neutrino mass matrix is assumed to be the reason for maximal - mixing, one gets 13 = 0 and 13 ≃ $\\sqrt{ m^{2}_{\\odot} / m^{2}_{{\\text{A}}}$ or 13 ≃ $ m^{2}_{\\odot} / m^{2}_{{\\text{A}}}$ can provide information about the way the ↔ symmetry breaking manifests in the case of normal hierarchy.

  11. Measuring stellar differential rotation with high-precision space-borne photometry

    CERN Document Server

    Lanza, A F; De Medeiros, J R

    2014-01-01

    We introduce a method of measuring a lower limit to the amplitude of surface differential rotation from high-precision, evenly sampled photometric time series. It is applied to main-sequence late-type stars whose optical flux modulation is dominated by starspots. An autocorrelation of the time series was used to select stars that allow an accurate determination of starspot rotation periods. A simple two-spot model was applied together with a Bayesian information criterion to preliminarily select intervals of the time series showing evidence of differential rotation with starspots of almost constant area. Finally, the significance of the differential rotation detection and a measurement of its amplitude and uncertainty were obtained by an a posteriori Bayesian analysis based on a Monte Carlo Markov Chain approach. We applied our method to the Sun and eight other stars for which previous spot modelling had been performed to compare our results with previous ones. We find that autocorrelation is a simple method ...

  12. High Precision Measurements of Carbon Disulfide Negative Ion Mobility and Diffusion

    CERN Document Server

    Snowden-Ifft, D P

    2013-01-01

    High precision measurements were made of mobility, lateral and longitudinal diffusion of CS2 negative ions in 40 Torr CS2 and 30 - 10 Torr CS2 - CF4. The mobility was found to be be 363.1 +/- 0.5 Torr cm2 / s V in CS2 and 408.0 +/- 0.8 Torr cm2 / s V in the CS2 - CF4 gas mixture. The lateral diffusion temperatures for these two gases (295 +/- 15 K and 297 +/- 6 K) were found to be in good agreement with room temperature. By contrast longitudinal diffusion temperature was found to be slightly elevated (319 +/- 10 (stat) +/- 8 (sys) K and 310 +/- 20 (stat) +/- 6 (sys) K) though given the errors, room temperature diffusion can not be ruled out. For lateral diffusion significant capture distances (0.21 +/- 0.07 mm and 0.15 +/- 0.03 mm) were measured while for longitudinal diffusion the results were not conclusive.

  13. High-precision optomechanical lens system for space applications assembled by a local soldering technique

    Science.gov (United States)

    Pleguezuelo, Pol Ribes; Koechlin, Charlie; Hornaff, Marcel; Kamm, Andreas; Beckert, Erik; Fiault, Guillaume; Eberhardt, Ramona; Tünnermann, Andreas

    2016-06-01

    Soldering using metallic solder alloys is an alternative to adhesive bonding. Laser-based soldering processes are especially well suited for the joining of optical components made of fragile and brittle materials such as glass, ceramics, and optical crystals. This is due to a localized and minimized input of thermal energy. Solderjet bumping technology has been used to assemble a lens mount breadboard using specifications and requirements found for the optical beam expander for the European Space Agency EarthCare Mission. The silica lens and a titanium barrel have been designed and assembled with this technology in order to withstand the stringent mission demands of handling high mechanical and thermal loads without losing the optical performance. Finally, a high-precision optomechanical lens mount has been assembled with minimal localized stress (<1 MPa) showing outstanding performance in terms of wave-front error and beam depolarization ratio before and after environmental tests.

  14. High-precision soft x-ray polarimeter at Diamond Light Source

    Science.gov (United States)

    Wang, H.; Dhesi, S. S.; Maccherozzi, F.; Cavill, S.; Shepherd, E.; Yuan, F.; Deshmukh, R.; Scott, S.; van der Laan, G.; Sawhney, K. J. S.

    2011-12-01

    The development and performance of a high-precision polarimeter for the polarization analysis in the soft x-ray region is presented. This versatile, high-vacuum compatible instrument is supported on a hexapod to simplify the alignment with a resolution less than 5 μrad, and can be moved with its own independent control system easily between different beamlines and synchrotron facilities. The polarimeter can also be used for the characterization of reflection and transmission properties of optical elements. A W/B4C multilayer phase retarder was used to characterize the polarization state up to 1200 eV. A fast and accurate alignment procedure was developed, and complete polarization analysis of the APPLE II undulator at 712 eV has been performed.

  15. High Precision Calculations of the Lennard-Jones Lattice Constants for Five Lattices

    Science.gov (United States)

    Stein, Matthew

    2017-01-01

    The total potential energy of a crystal as described by the Lennard-Jones (L-J) potential depends in part upon the calculation of lattice constants. Knowing these constants to high precision is useful for prediction of the lattice type and simulation of crystals such as rare-gas solids or germanium detectors, but reaching higher precision is computationally costly and challenging. Presented here is the extension of the precision of the lattice constants, Lp, up to 32 decimal digits, and in some cases corrections from previous publication. The Lp terms are given for 4 cubic, face-centered cubic, body-centered cubic, hexagonal-close-pack, and diamond lattices. This precision was obtained through the use of careful parallelization technique, exploitation of the symmetries of each lattice, and the ``onionization'' of the simulated crystal. The results of this computation, along with the tools and algorithm strategies to make this computation possible, are explained in detail graphically.

  16. A comparison of cosmological Boltzmann codes: are we ready for high precision cosmology?

    CERN Document Server

    Seljak, U; White, M; Zaldarriaga, M

    2003-01-01

    We compare three independent, cosmological linear perturbation theory codes to asses the level of agreement between them and to improve upon it by investigating the sources of discrepancy. By eliminating the major sources of numerical instability the final level of agreement between the codes was improved by an order of magnitude. The relative error is now below 0.1% for the dark matter power spectrum. For the cosmic microwave background anisotropies the agreement is below the sampling variance up to l=3000, with close to 0.1% accuracy reached over most of this range of scales. The same level of agreement is also achieved for the polarization spectrum and the temperature-polarization cross-spectrum. Linear perturbation theory codes are thus well prepared for the present and upcoming high precision cosmological observations.

  17. High-Precision Determination of the Pion-Nucleon σ Term from Roy-Steiner Equations

    Science.gov (United States)

    Hoferichter, Martin; Ruiz de Elvira, Jacobo; Kubis, Bastian; Meißner, Ulf-G.

    2015-08-01

    We present a determination of the pion-nucleon (π N ) σ term σπ N based on the Cheng-Dashen low-energy theorem (LET), taking advantage of the recent high-precision data from pionic atoms to pin down the π N scattering lengths as well as of constraints from analyticity, unitarity, and crossing symmetry in the form of Roy-Steiner equations to perform the extrapolation to the Cheng-Dashen point in a reliable manner. With isospin-violating corrections included both in the scattering lengths and the LET, we obtain σπ N=(59.1 ±1.9 ±3.0 ) MeV =(59.1 ±3.5 ) MeV , where the first error refers to uncertainties in the π N amplitude and the second to the LET. Consequences for the scalar nucleon couplings relevant for the direct detection of dark matter are discussed.

  18. High Precision Stokes Polarimetry for Scattering Light using Wide Dynamic Range Intensity Detector

    Directory of Open Access Journals (Sweden)

    Shibata Shuhei

    2015-01-01

    Full Text Available This paper proposes a Stokes polarimetry for scattering light from a sample surface. To achieve a high accuracy measurement two approaches of an intensity detector and analysis algorism of a Stokes parameter were proposed. The dynamic range of this detector can achieve up to 1010 by combination of change of neutral-density (ND filters having different density and photon counting units. Stokes parameters can be measured by dual rotating of a retarder and an analyzer. The algorism of dual rotating polarimeter can be calibrated small linear diattenuation and linear retardance error of the retarder. This system can measured Stokes parameters from −20° to 70° of its scattering angle. It is possible to measure Stokes parameters of scattering of dust and scratch of optical device with high precision. This paper shows accuracy of this system, checking the polarization change of scattering angle and influence of beam size.

  19. Efficient high-precision matrix algebra on parallel architectures for nonlinear combinatorial optimization

    KAUST Repository

    Gunnels, John

    2010-06-01

    We provide a first demonstration of the idea that matrix-based algorithms for nonlinear combinatorial optimization problems can be efficiently implemented. Such algorithms were mainly conceived by theoretical computer scientists for proving efficiency. We are able to demonstrate the practicality of our approach by developing an implementation on a massively parallel architecture, and exploiting scalable and efficient parallel implementations of algorithms for ultra high-precision linear algebra. Additionally, we have delineated and implemented the necessary algorithmic and coding changes required in order to address problems several orders of magnitude larger, dealing with the limits of scalability from memory footprint, computational efficiency, reliability, and interconnect perspectives. © Springer and Mathematical Programming Society 2010.

  20. High precision metrology method for unobscured Three Mirror Anastigmatic (TMA) mapping camera boresight

    Science.gov (United States)

    Zhao, Xi-ting; Jiao, Wen-chun; Liao, Zhi-bo

    2012-10-01

    High precision of mapping camera boresight directly affects the positioning accuracy of geographical location and photogrammetry. Although it can fulfill the request of good performance for unobscured TMA optical system, which adopted computer aided alignment method, single lens was unobscured which unable ascertain boresight by using lens centering technology, and boresight is randomicity as a result of compensating relation of multivariables. A novel method using the measurement of theodolite space intersection was proposed to rapidly and high accurately complete establish the relation between boresight and a cube in precision alignment stage, simultaneously, the relation of component deflexion and boresight have been simulated by computer model reverse optimization. Thus, the image quality and precision of boresight was effective operated according to the request of satellite assembly.

  1. The high precision measurement of the 144Ce activity in the SOX experiment

    Science.gov (United States)

    Di Noto, L.; Agostini, M.; Althenmüller, K.; Appel, S.; Bellini, G.; Benziger, J.; Berton, N.; Bick, D.; Bonfini, G.; Bravo—Berguño, D.; Caccianiga, B.; Calaprice, F.; Caminata, A.; Cavalcante, P.; Cereseto, R.; Chepurnov, A.; Choi, K.; Cribier, M.; DAngelo, D.; Davini, S.; Derbin, A.; Drachnev, I.; Durero, M.; Etenko, A.; Farinon, S.; Fischer, V.; Fomenko, K.; Franco, D.; Gabriele, F.; Gaffiot, J.; Galbiati, C.; Ghiano, C.; Giammarchi, M.; Göeger-Neff, M.; Goretti, A.; Gromov, M.; Hagner, C.; Houdy, Th; Hungerford, E.; Ianni, Aldo; Ianni, Andrea; Jonquères, N.; Jedrzejczak, K.; Kaiser, M.; Kobychev, V.; Korablev, D.; Korga, G.; Kornoukhov, V.; Kryn, D.; Lachenmaier, T.; Lasserre, T.; Laubenstein, M.; Lehnert, T.; Link, J.; Litvinovich, E.; Lombardi, F.; Lombardi, P.; Ludhova, L.; Lukyanchenko, G.; Machulin, I.; Manecki, S.; Maneschg, W.; Marcocci, S.; Maricic, J.; Mention, G.; Meroni, E.; Meyer, M.; Miramonti, L.; Misiaszek, M.; Montuschi, M.; Mosteiro, P.; Muratova, V.; Musenich, R.; Neumair, B.; Oberauer, L.; Obolensky, M.; Ortica, F.; Pallavicini, M.; Papp, L.; Perasso, L.; Pocar, A.; Ranucci, G.; Razeto, A.; Re, A.; Romani, A.; Roncin, R.; Rossi, C.; Rossi, N.; Schönert, S.; Scola, L.; Semenov, D.; Simgen, H.; Skorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Sukhotin, S.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Thurn, J.; Toropova, M.; Veyssière, C.; Vivier, M.; Unzhakov, E.; Vogelaar, R. B.; von Feilitzsch, F.; Wang, H.; Weinz, S.; Winter, J.; Wojcik, M.; Wurm, M.; Yokley, Z.; Zaimidoroga, O.; Zavatarelli, S.; Zuber, K.; Zuzel, G.

    2016-02-01

    In order to perform a resolutive measurement to clarify the neutrino anomalies and to observe possible short distance neutrino oscillations, the SOX (Short distance neutrino Oscillations with BoreXino) experiment is under construction. In the first phase, a 100 kCi 144Ce-144Pr antineutrino source will be placed under the Borexino detector at the Laboratori Nazionali del Gran Sasso (LNGS), in center of Italy, and the rate measurement of the antineutrino events, observed by the very low radioactive background Borexino detector, will be compared with the high precision (< 1%) activity measurement performed by two calorimeters. The source will be embedded in a 19 mm thick tungsten alloy shield and both the calorimeters have been conceived for measuring the thermal heat absorbed by a water flow. In this report the design of the calorimeters will be described in detail and very preliminary results will be also shown.

  2. New high precision data on the differential cross sections of the pion-proton elastic scattering

    Directory of Open Access Journals (Sweden)

    Alekseev I. G.

    2014-01-01

    Full Text Available The EPECUR collaboration presents new high precision data on the pion-proton elastic scattering in the second resonance region. The experiment EPECUR is placed on the universal beam channel of the accelerator ITEP. The setup features 0.1% beam pion momentum tagging system, 25 cm long liquid hydrogen target, placed in mylar container and beryllium outer shell, low material wire drift chambers and high performance DAQ. More than 3 billions of triggers have been collected. The data cover pion beam momentum range 0.8 - 1.3 GeV/c and 40-120 degrees center-of-mass scattering angle range for both positive and negative pions. The measured differential cross section has 2% statistical accuracy in 2 degrees angle and 5 MeV/c momentum intervals.

  3. High-precision atom localization via controllable spontaneous emission in a cycle-configuration atomic system.

    Science.gov (United States)

    Ding, Chunling; Li, Jiahua; Yu, Rong; Hao, Xiangying; Wu, Ying

    2012-03-26

    A scheme for realizing two-dimensional (2D) atom localization is proposed based on controllable spontaneous emission in a coherently driven cycle-configuration atomic system. As the spatial-position-dependent atom-field interaction, the frequency of the spontaneously emitted photon carries the information about the position of the atom. Therefore, by detecting the emitted photon one could obtain the position information available, and then we demonstrate high-precision and high-resolution 2D atom localization induced by the quantum interference between the multiple spontaneous decay channels. Moreover, we can achieve 100% probability of finding the atom at an expected position by choosing appropriate system parameters under certain conditions.

  4. A sub-1 V high-precision CMOS bandgap voltage reference

    Institute of Scientific and Technical Information of China (English)

    廖峻; 赵毅强; 耿俊峰

    2012-01-01

    A third-order,sub-1 V bandgap voltage reference design for low-power supply,high-precision applications is presented.This design uses a current-mode compensation technique and temperature-dependent resistor ratio to obtain high-order curvature compensation.The circuit was designed and fabricated by SMIC 0.18μm CMOS technology.It produces an output reference of 713.6 mV.The temperature coefficient is 3.235 pprn/℃ in the temperature range of-40 to 120 ℃,with a line regulation of 0.199 mV/V when the supply voltage varies from 0.95 to 3 V.The average current consumption of the whole circuit is 49 μA at the supply voltage of 1 V.

  5. A fast high-precision six-degree-of-freedom relative position sensor

    Science.gov (United States)

    Hughes, Gary B.; Macasaet, Van P.; Griswold, Janelle; Sison, Claudia A.; Lubin, Philip; Meinhold, Peter; Suen, Jonathan; Brashears, Travis; Zhang, Qicheng; Madajian, Jonathan

    2016-03-01

    Lasers are commonly used in high-precision measurement and profiling systems. Some laser measurement systems are based on interferometry principles, and others are based on active triangulation, depending on requirements of the application. This paper describes an active triangulation laser measurement system for a specific application wherein the relative position of two fixed, rigid mechanical components is to be measured dynamically with high precision in six degrees of freedom (DOF). Potential applications include optical systems with feedback to control for mechanical vibration, such as target acquisition devices with multiple focal planes. The method uses an array of several laser emitters mounted on one component. The lasers are directed at a reflective surface on the second component. The reflective surface consists of a piecewise-planar pattern such as a pyramid, or more generally a curved reflective surface such as a hyperbolic paraboloid. The reflected spots are sensed at 2-dimensional photodiode arrays on the emitter component. Changes in the relative position of the emitter component and reflective surface will shift the location of the reflected spots within photodiode arrays. Relative motion in any degree of freedom produces independent shifts in the reflected spot locations, allowing full six-DOF relative position determination between the two component positions. Response time of the sensor is limited by the read-out rate of the photodiode arrays. Algorithms are given for position determination with limits on uncertainty and sensitivity, based on laser and spot-sensor characteristics, and assuming regular surfaces. Additional uncertainty analysis is achievable for surface irregularities based on calibration data.

  6. Gravity Compensation Using EGM2008 for High-Precision Long-Term Inertial Navigation Systems

    Directory of Open Access Journals (Sweden)

    Ruonan Wu

    2016-12-01

    Full Text Available The gravity disturbance vector is one of the major error sources in high-precision and long-term inertial navigation applications. Specific to the inertial navigation systems (INSs with high-order horizontal damping networks, analyses of the error propagation show that the gravity-induced errors exist almost exclusively in the horizontal channels and are mostly caused by deflections of the vertical (DOV. Low-frequency components of the DOV propagate into the latitude and longitude errors at a ratio of 1:1 and time-varying fluctuations in the DOV excite Schuler oscillation. This paper presents two gravity compensation methods using the Earth Gravitational Model 2008 (EGM2008, namely, interpolation from the off-line database and computing gravity vectors directly using the spherical harmonic model. Particular attention is given to the error contribution of the gravity update interval and computing time delay. It is recommended for the marine navigation that a gravity vector should be calculated within 1 s and updated every 100 s at most. To meet this demand, the time duration of calculating the current gravity vector using EGM2008 has been reduced to less than 1 s by optimizing the calculation procedure. A few off-line experiments were conducted using the data of a shipborne INS collected during an actual sea test. With the aid of EGM2008, most of the low-frequency components of the position errors caused by the gravity disturbance vector have been removed and the Schuler oscillation has been attenuated effectively. In the rugged terrain, the horizontal position error could be reduced at best 48.85% of its regional maximum. The experimental results match with the theoretical analysis and indicate that EGM2008 is suitable for gravity compensation of the high-precision and long-term INSs.

  7. Gravity Compensation Using EGM2008 for High-Precision Long-Term Inertial Navigation Systems.

    Science.gov (United States)

    Wu, Ruonan; Wu, Qiuping; Han, Fengtian; Liu, Tianyi; Hu, Peida; Li, Haixia

    2016-12-18

    The gravity disturbance vector is one of the major error sources in high-precision and long-term inertial navigation applications. Specific to the inertial navigation systems (INSs) with high-order horizontal damping networks, analyses of the error propagation show that the gravity-induced errors exist almost exclusively in the horizontal channels and are mostly caused by deflections of the vertical (DOV). Low-frequency components of the DOV propagate into the latitude and longitude errors at a ratio of 1:1 and time-varying fluctuations in the DOV excite Schuler oscillation. This paper presents two gravity compensation methods using the Earth Gravitational Model 2008 (EGM2008), namely, interpolation from the off-line database and computing gravity vectors directly using the spherical harmonic model. Particular attention is given to the error contribution of the gravity update interval and computing time delay. It is recommended for the marine navigation that a gravity vector should be calculated within 1 s and updated every 100 s at most. To meet this demand, the time duration of calculating the current gravity vector using EGM2008 has been reduced to less than 1 s by optimizing the calculation procedure. A few off-line experiments were conducted using the data of a shipborne INS collected during an actual sea test. With the aid of EGM2008, most of the low-frequency components of the position errors caused by the gravity disturbance vector have been removed and the Schuler oscillation has been attenuated effectively. In the rugged terrain, the horizontal position error could be reduced at best 48.85% of its regional maximum. The experimental results match with the theoretical analysis and indicate that EGM2008 is suitable for gravity compensation of the high-precision and long-term INSs.

  8. Computational Calorimetry: High-Precision Calculation of Host-Guest Binding Thermodynamics.

    Science.gov (United States)

    Henriksen, Niel M; Fenley, Andrew T; Gilson, Michael K

    2015-09-08

    We present a strategy for carrying out high-precision calculations of binding free energy and binding enthalpy values from molecular dynamics simulations with explicit solvent. The approach is used to calculate the thermodynamic profiles for binding of nine small molecule guests to either the cucurbit[7]uril (CB7) or β-cyclodextrin (βCD) host. For these systems, calculations using commodity hardware can yield binding free energy and binding enthalpy values with a precision of ∼0.5 kcal/mol (95% CI) in a matter of days. Crucially, the self-consistency of the approach is established by calculating the binding enthalpy directly, via end point potential energy calculations, and indirectly, via the temperature dependence of the binding free energy, i.e., by the van't Hoff equation. Excellent agreement between the direct and van't Hoff methods is demonstrated for both host-guest systems and an ion-pair model system for which particularly well-converged results are attainable. Additionally, we find that hydrogen mass repartitioning allows marked acceleration of the calculations with no discernible cost in precision or accuracy. Finally, we provide guidance for accurately assessing numerical uncertainty of the results in settings where complex correlations in the time series can pose challenges to statistical analysis. The routine nature and high precision of these binding calculations opens the possibility of including measured binding thermodynamics as target data in force field optimization so that simulations may be used to reliably interpret experimental data and guide molecular design.

  9. High-precision method of binocular camera calibration with a distortion model.

    Science.gov (United States)

    Li, Weimin; Shan, Siyu; Liu, Hui

    2017-03-10

    A high-precision camera calibration method for binocular stereo vision system based on a multi-view template and alternative bundle adjustment is presented in this paper. The proposed method could be achieved by taking several photos on a specially designed calibration template that has diverse encoded points in different orientations. In this paper, the method utilized the existing algorithm used for monocular camera calibration to obtain the initialization, which involves a camera model, including radial lens distortion and tangential distortion. We created a reference coordinate system based on the left camera coordinate to optimize the intrinsic parameters of left camera through alternative bundle adjustment to obtain optimal values. Then, optimal intrinsic parameters of the right camera can be obtained through alternative bundle adjustment when we create a reference coordinate system based on the right camera coordinate. We also used all intrinsic parameters that were acquired to optimize extrinsic parameters. Thus, the optimal lens distortion parameters and intrinsic and extrinsic parameters were obtained. Synthetic and real data were used to test the method. The simulation results demonstrate that the maximum mean absolute relative calibration errors are about 3.5e-6 and 1.2e-6 for the focal length and the principal point, respectively, under zero-mean Gaussian noise with 0.05 pixels standard deviation. The real result shows that the reprojection error of our model is about 0.045 pixels with the relative standard deviation of 1.0e-6 over the intrinsic parameters. The proposed method is convenient, cost-efficient, highly precise, and simple to carry out.

  10. Toward high-precision values of the self energy of non-S states in hydrogen and hydrogen-like ions

    CERN Document Server

    Le Bigot, E O; Jentschura, U D; Mohr, P J; Bigot, Eric-Olivier Le; Indelicato, Paul; Jentschura, Ulrich D.; Mohr, Peter J.; ccsd-00003072, ccsd

    2004-01-01

    The method and status of a study to provide numerical, high-precision values of the self-energy level shift in hydrogen and hydrogen-like ions is described. Graphs of the self energy in hydrogen-like ions with nuclear charge number between 20 and 110 are given for a large number of states. The self-energy is the largest contribution of Quantum Electrodynamics (QED) to the energy levels of these atomic systems. These results greatly expand the number of levels for which the self energy is known with a controlled and high precision. Applications include the adjustment of the Rydberg constant and atomic calculations that take into account QED effects.

  11. High resolution and high precision absorption spectroscopy using high finesse cavities: application to the study of molecules with atmospheric interest; Cavites de haute finesse pour la spectroscopie d'absorption haute sensibilite et haute precision: application a l'etude de molecules d'interet atmospherique

    Energy Technology Data Exchange (ETDEWEB)

    Motto-Ros, V.

    2005-12-15

    High finesse cavities are used to measure very weak absorption features. Two different methodologies are investigated and applied to the study of molecules with atmospheric interest. First, Continuous Wave - Cavity Ring Down Spectroscopy (CW-CRDS) is used to study the atmospheric spectra of water vapour in the near infrared range. These measurements are performed for temperature and pressure of atmospheric relevance for DIAL applications (Differential Absorption Lidar). This study, financed by the European Space Agency (ESA), goes with the WALES mission (Water Vapour Lidar Experiment in Space). The experimental setup was conceived in order to control pressure, temperature and relative humidity conditions. A particular attention is done to characterize and describe the spectrometer. Then, measurements of red Oxygen B band are performed to demonstrate the huge performance of Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS). The desired optical feedback is obtained by light injection into the high finesse cavity through a glass plate placed inside the cavity and closed to the Brewster angle. We show a measurement dynamical range of 5 orders of magnitude (10{sup -5} to 10{sup -10} /cm) and a sensitivity of 10{sup -10} /cm/{radical} Hz. Also, sampling absorption spectra by the super linear cavity frequency comb allows very precise frequency measurements. This is demonstrated by the determination of Oxygen pressure shifts with an absolute accuracy of around 5 x 10{sup -5} cm{sup -1}/atm. To our knowledge, we provide the highest accuracy ever reported for this parameter. (author)

  12. Systematic study of gas mixtures for timing RPCs

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, L., E-mail: luisalberto@coimbra.lip.pt [LIP-Laboratorio de Instrumentacao e Fisica Experimental de Particulas, 3004-516 Coimbra (Portugal); Fonte, P. [LIP-Laboratorio de Instrumentacao e Fisica Experimental de Particulas, 3004-516 Coimbra (Portugal); Intituto Superior de Engenharia de Coimbra, 3030-199 Coimbra (Portugal); Mangiarotti, A. [LIP-Laboratorio de Instrumentacao e Fisica Experimental de Particulas, 3004-516 Coimbra (Portugal)

    2012-01-01

    RPC timing properties are mainly determined by the maximum ionization rate that can be sustained while keeping the streamer fraction at modest values. The last characteristic, resilience to streamers, cannot be fully calculated, calling for an experimental approach. In this work we systematically study the influence of a range of gas mixtures on the performance (background counting rate, efficiency, time resolution and charge spectrum) of timing RPCs, using cosmic rays as ionizing particles.

  13. Damage and loss assessment on rubber trees caused by typhoon based on high-precision remote sensing data and field investigation

    Science.gov (United States)

    Li, Jian; Fang, Weihua; Tan, Chenyan

    2016-04-01

    Forest dynamics are highly relevant to land hydrology, climate, carbon budget and biodiversity. Damage and loss assessment of forest caused by typhoon is essential to the understanding of ecosystem variations. Combination of high-precision remote sensing data and field investigation is critical to the assessment of forest damage loss. In this study, high-precision remote sensing data prior to and after typhoon from IKONOS, QuickBird, unmanned aerial vehicle (UAV) are used for identifying rubber tree disturbance. The ground truth data of rubber tree damage collected through field investigation are used to verify and compare the results. Taken the forest damage induced by typhoon Rammasun (201409) in Hainan as an example, 5 damage types (overthrown, trunk snapped below 2m, trunk snapped above 2m, half-overthrown, and sheared) of rubber trees are clearly interpreted compared with field investigation results. High-precision remote sensing data is then applied to other areas to evaluate the forest damage severity. At last, rubber tree damage severity is investigated with other typhoon hazard factors such as wind, topography, soil and precipitation.

  14. Development of High Precision Tsunami Runup Calculation Method Coupled with Structure Analysis

    Science.gov (United States)

    Arikawa, Taro; Seki, Katsumi; Chida, Yu; Takagawa, Tomohiro; Shimosako, Kenichiro

    2017-04-01

    The 2011 Great East Japan Earthquake (GEJE) has shown that tsunami disasters are not limited to inundation damage in a specified region, but may destroy a wide area, causing a major disaster. Evaluating standing land structures and damage to them requires highly precise evaluation of three-dimensional fluid motion - an expensive process. Our research goals were thus to develop a coupling STOC-CADMAS (Arikawa and Tomita, 2016) coupling with the structure analysis (Arikawa et. al., 2009) to efficiently calculate all stages from tsunami source to runup including the deformation of structures and to verify their applicability. We also investigated the stability of breakwaters at Kamaishi Bay. Fig. 1 shows the whole of this calculation system. The STOC-ML simulator approximates pressure by hydrostatic pressure and calculates the wave profiles based on an equation of continuity, thereby lowering calculation cost, primarily calculating from a e epi center to the shallow region. As a simulator, STOC-IC solves pressure based on a Poisson equation to account for a shallower, more complex topography, but reduces computation cost slightly to calculate the area near a port by setting the water surface based on an equation of continuity. CS3D also solves a Navier-Stokes equation and sets the water surface by VOF to deal with the runup area, with its complex surfaces of overflows and bores. STR solves the structure analysis including the geo analysis based on the Biot's formula. By coupling these, it efficiently calculates the tsunami profile from the propagation to the inundation. The numerical results compared with the physical experiments done by Arikawa et. al.,2012. It was good agreement with the experimental ones. Finally, the system applied to the local situation at Kamaishi bay. The almost breakwaters were washed away, whose situation was similar to the damage at Kamaishi bay. REFERENCES T. Arikawa and T. Tomita (2016): "Development of High Precision Tsunami Runup

  15. High-precision temporal constraints on intrusive magmatism of the Siberian Traps

    Science.gov (United States)

    Burgess, Seth; Bowring, Sam; Pavlov, Volodia E.; Veselovsky, Roman V.

    2014-05-01

    The broad temporal coincidence between large igneous province magmatism and some of the most severe biotic/environmental crises in Earth history has led many to infer a causal connection between the two. Notable examples include the end-Permian mass extinction and eruption/emplacement of the Siberian Traps large igneous province (LIP) and the end-Triassic mass extinction and the Central Atlantic Magmatic Province. In models proposing a causal connection between LIP magmatism and the environmental changes that lead to mass extinction, gases and particulates injected into the atmosphere are thought to cause abrupt changes in climate and ocean chemistry sufficient to drive mass extinction of marine and terrestrial biota. Magmatism has been proposed to cause voluminous volatile release via contact metamorphism of the sedimentary rocks. In the case of the Siberian Traps LIP, the compositions of sedimentary rocks (carbonates, evaporates, organic-rich shales) that host sills and dikes are ideal for greenhouse gas generation. When coupled with the enormous volume of Siberian LIP intrusive rocks, there is the potential for volatile generation on a scale necessary to drive environmental changes and mass extinction. This model must be tested by comparing the timing of intrusive magmatism with that of the mass extinction. Coupled high-precision geochronology and astrochronology have constrained the timing of biotic crisis and associated environmental perturbations from the deca-millennial to sub-millennial timescale, suggesting that the biotic crisis was abrupt, occurring over < 100 ka. Published geochronology on sills and dikes from the LIP are sparse and lack the necessary precision to resolve the relative timing of the two events outside of age uncertainty. We present new high-precision U-Pb zircon geochronology on seventeen gabbroic sills from throughout the magmatic province. This includes samples from the mineralized and differentiated intrusions in the Noril'sk region

  16. Can we systematically review studies that evaluate complex interventions?

    Directory of Open Access Journals (Sweden)

    Sasha Shepperd

    2009-08-01

    Full Text Available BACKGROUND TO THE DEBATE: The UK Medical Research Council defines complex interventions as those comprising "a number of separate elements which seem essential to the proper functioning of the interventions although the 'active ingredient' of the intervention that is effective is difficult to specify." A typical example is specialist care on a stroke unit, which involves a wide range of health professionals delivering a variety of treatments. Michelle Campbell and colleagues have argued that there are "specific difficulties in defining, developing, documenting, and reproducing complex interventions that are subject to more variation than a drug". These difficulties are one of the reasons why it is challenging for researchers to systematically review complex interventions and synthesize data from separate studies. This PLoS Medicine Debate considers the challenges facing systematic reviewers and suggests several ways of addressing them.

  17. High-precision measurements of cementless acetabular components using model-based RSA: an experimental study

    DEFF Research Database (Denmark)

    Baad-Hansen, Thomas; Kold, Søren; Kaptein, Bart L;

    2007-01-01

    BACKGROUND: In RSA, tantalum markers attached to metal-backed acetabular cups are often difficult to detect on stereo radiographs due to the high density of the metal shell. This results in occlusion of the prosthesis markers and may lead to inconclusive migration results. Within the last few yea...

  18. Study of a high-precision SAW-MOEMS strain sensor with laser optics

    Science.gov (United States)

    Liu, Xinwei; Chen, Shufen; Li, Honglang; Zou, Zhengfeng; Fu, Lei; Meng, Yanbin

    2015-02-01

    A novel structure design of a surface acoustic wave (SAW) micro-optic-electro-mechanical-system (MOEMS) strain sensor with a light readout unit is presented in this paper. By measuring the polarization intensity ratio of the TE/TM mode outputted from the waveguide, the strain produced from an object can be measured precisely. The basic working principle of the SAW MOEMS strain sensor is introduced and the mathematical model of the strain sensor system is established. The SAW characteristics effected by the strain sensor are mathematically deduced. The coupling coefficient between the SAW modes and light modes can be calculated based on the theory of coupling modes. The conversion coefficient of polarized light modes is obtained. Due to the restrictions of the specific parameters of the device, the level of technology and the material characteristics, the sensitivity of the strain sensor system is calculated through simulation as 0.1 μɛ, with a dynamic range of 0 ~ ±50 μɛ.

  19. Studies on high-precision machining and assembly of CLIC RF structures

    CERN Document Server

    Huopana, J; Riddone, G; Österberg, K

    2010-01-01

    The Compact Linear Collider (CLIC) is currently under development at CERN as a potential multi-TeV e+e– collider. The manufacturing and assembly tolerances for the required RF components are essential for the final efficiency and for the operation of CLIC. The proper function of an accelerating structure is sensitive to mechanical errors in the shape and the alignment of the accelerating cavity. The current tolerances are in the micron range. This raises challenges in the field of mechanical design and demands special manufacturing technologies and processes. Currently the mechanical design of the accelerating structures is based on a disk design. Alternatively, it is possible to create the accelerating assembly from quadrants, which has the potential to be favoured for the mass production due to simplicity and cost. In this case, the functional shape inside of the accelerating structure remains the same and a single assembly uses less parts. This paper focuses on the development work done in design and sim...

  20. High-Precision Timing of 5 Millisecond Pulsars: Space Velocities, Binary Evolution and Equivalence Principles

    CERN Document Server

    Gonzalez, M E; Ferdman, R D; Freire, P C C; Nice, D J; Demorest, P B; Ransom, S M; Kramer, M; Camilo, F; Hobbs, G; Manchester, R N; Lyne, A G

    2011-01-01

    We present high-precision timing of five millisecond pulsars (MSPs) carried out for more than seven years; four pulsars are in binary systems and one is isolated. We are able to measure the pulsars' proper motions and derive an estimate for their space velocities. The measured two-dimensional velocities are in the range 70-210 km/s, consistent with those measured for other MSPs. We also use all the available proper motion information for isolated and binary MSPs to update the known velocity distribution for these populations. As found by earlier works, we find that the velocity distribution of binary and isolated MSPs are indistinguishable with the current data. Four of the pulsars in our observing program are highly recycled with low-mass white dwarf companions and we are able to derive accurate binary parameters for these systems. For three of these binary systems we are able to place initial constraints on the pulsar masses with best-fit values in the range 1.0-1.6 M_sun. The implications of the results pr...

  1. Supplementary comparison EURAMET.L-S23 (#1269) high precision roundness measurement by error separation techniques

    Science.gov (United States)

    Prieto, Emilio; Muñoz, Rafael; Arce, Aelio A.; Bergmans, Rob; Kotte, Gerard; Holmberg, Maria; Svendsmark, Maria; Toftegaard, Jens Bo; Astrua, Milena; Pisani, Marco; Saraiva, Fernanda; Eusebio, Liliana; Nouira, Hichem; Salgado, José A.

    2017-01-01

    At its meeting in October 2012, the EURAMET Technical Committee for Length, EURAMET TC-L, decided that a key comparison on high precision roundness measurement by multi-step method shall be carried out with CEM acting as the pilot laboratory. The roundness standards to be calibrated were chosen to be a glass hemisphere with a diameter of about 50 mm and a sphere with a diameter of about 30 mm. A goal of the key comparisons for topics in dimensional metrology is to demonstrate the equivalence of routine calibration services offered by NMIs to clients, as listed in appendix C of the Mutual Recognition Agreement (MRA). To this end, participants in this comparison agreed to use the same apparatus and methods as routinely applied to client artefacts. The comparison was registered in March 2013 as Project EURAMET 1269 and at KCDB as supplementary comparison EURAMET.L-S23.2013. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Challenges in mold manufacturing for high precision molded diffractive optical elements

    Science.gov (United States)

    Pongs, Guido; Bresseler, Bernd; Schweizer, Klaus; Bergs, Thomas

    2016-09-01

    Isothermal precision glass molding of imaging optics is the key technology for mass production of precise optical elements. Especially for numerous consumer applications (e.g. digital cameras, smart phones, …), high precision glass molding is applied for the manufacturing of aspherical lenses. The usage of diffractive optical elements (DOEs) can help to further reduce the number of lenses in the optical systems which will lead to a reduced weight of hand-held optical devices. But today the application of molded glass DOEs is limited due to the technological challenges in structuring the mold surfaces. Depending on the application submicrometer structures are required on the mold surface. Furthermore these structures have to be replicated very precisely to the glass lens surface. Especially the micro structuring of hard and brittle mold materials such as Tungsten Carbide is very difficult and not established. Thus a multitude of innovative approaches using diffractive optical elements cannot be realized. Aixtooling has investigated in different mold materials and different suitable machining technologies for the micro- and sub-micrometer structuring of mold surfaces. The focus of the work lays on ultra-precision grinding to generate the diffractive pattern on the mold surfaces. This paper presents the latest achievements in diffractive structuring of Tungsten Carbide mold surfaces by ultra-precision grinding.

  3. GIARPS: the unique VIS-NIR high precision radial velocity facility in this world

    CERN Document Server

    Claudi, Riccardo; Carleo, Ilaria; Ghedina, Adriano; Molinari, Emilio; Oliva, Ernesto; Tozzi, Andrea; Baruffolo, Andrea; Cecconi, Massimo; Cosentino, Rosario; Fantinel, Daniela; Fini, Luca; Ghinassi, Francesca; Gonzalez, Manuel; Gratton, Raffaele; Guerra, Jose; Harutyunyan, Avet; Hernandez, Nauzet; Iuzzolino, Marcella; Lodi, Marcello; Malavolta, Luca; Maldonado, Jesus; Micela, Giusi; Sanna, Nicoletta; Sanjuan, Jose; Scuderi, Salvo; Sozzetti, Alessandro; Ventura, Hector Perez; Diaz, Marcos Hernandez; Galli, Alberto; Gonzalez, Carlos; Riverol, Luis; Riverol, Carlos

    2016-01-01

    GIARPS (GIAno & haRPS) is a project devoted to have on the same focal station of the Telescopio Nazionale Galileo (TNG) both the high resolution spectrographs HARPS-N (VIS) and GIANO (NIR) working simultaneously. This could be considered the first and unique worldwide instrument providing cross-dispersed echelle spectroscopy at a high resolution (R=115,000 in the visual and R=50,000 in the IR) and over in a wide spectral range (0.383 - 2.45 micron) in a single exposure. The science case is very broad, given the versatility of such an instrument and the large wavelength range. A number of outstanding science cases encompassing mainly extra-solar planet science starting from rocky planet search and hot Jupiters, atmosphere characterization can be considered. Furthermore both instrument can measure high precision radial velocity by means the simultaneous thorium technique (HARPS - N) and absorbing cell technique (GIANO) in a single exposure. Other science cases are also possible. Young stars and proto-planet...

  4. High-Precision Temperature Control of a Crystal Growth Furnace at 1,500 C

    Science.gov (United States)

    Stenzel, Ch.; Hess, A.; Croell, A.; Breuer, D.; Sauermann, H.

    2012-01-01

    For crystal growth of semiconductor materials a short-term temperature stability of 0.1 C at 1500 C is one of the essential parameters to be addressed for achieving high-quality crystals. Hence, for temperature monitoring and control with high precision in a floating zone furnace two sets of thermo-sensors, type B thermocouples and optical fibre thermometers, have been implemented and successfully operated in the furnace for more than 2000 h. The optical fibre thermometers consist of an optical system made of sapphire (two fibres plus a prism in between for deflection) and transmit the infra-red radiation of the heater to the outside of the hot core of the furnace for pyrometric temperature measurement. A dedicated control algorithm has been set up which controlled the power settings to the individual heaters. Both sensor types showed no degradation after this period and yielded a short-term stability at 1200 C of 0.05 C (optical fibre thermometers), respectively 0.08 C (thermocouples).

  5. Development of high precision digital driver of acoustic-optical frequency shifter for ROG

    Science.gov (United States)

    Zhang, Rong; Kong, Mei; Xu, Yameng

    2016-10-01

    We develop a high precision digital driver of the acoustic-optical frequency shifter (AOFS) based on the parallel direct digital synthesizer (DDS) technology. We use an atomic clock as the phase-locked loop (PLL) reference clock, and the PLL is realized by a dual digital phase-locked loop. A DDS sampling clock up to 320 MHz with a frequency stability as low as 10-12 Hz is obtained. By constructing the RF signal measurement system, it is measured that the frequency output range of the AOFS-driver is 52-58 MHz, the center frequency of the band-pass filter is 55 MHz, the ripple in the band is less than 1 dB@3MHz, the single channel output power is up to 0.3 W, the frequency stability is 1 ppb (1 hour duration), and the frequency-shift precision is 0.1 Hz. The obtained frequency stability has two orders of improvement compared to that of the analog AOFS-drivers. For the designed binary frequency shift keying (2-FSK) and binary phase shift keying (2-PSK) modulation system, the demodulating frequency of the input TTL synchronous level signal is up to 10 kHz. The designed digital-bus coding/decoding system is compatible with many conventional digital bus protocols. It can interface with the ROG signal detecting software through the integrated drive electronics (IDE) and exchange data with the two DDS frequency-shift channels through the signal detecting software.

  6. Microsurgery robots: addressing the needs of high-precision surgical interventions.

    Science.gov (United States)

    Mattos, Leonardo S; Caldwell, Darwin G; Peretti, Giorgio; Mora, Francesco; Guastini, Luca; Cingolani, Roberto

    2016-01-01

    Robotics has a significant potential to enhance the overall capacity and efficiency of healthcare systems. Robots can help surgeons perform better quality operations, leading to reductions in the hospitalisation time of patients and in the impact of surgery on their postoperative quality of life. In particular, robotics can have a significant impact on microsurgery, which presents stringent requirements for superhuman precision and control of the surgical tools. Microsurgery is, in fact, expected to gain importance in a growing range of surgical specialties as novel technologies progressively enable the detection, diagnosis and treatment of diseases at earlier stages. Within such scenarios, robotic microsurgery emerges as one of the key components of future surgical interventions, and will be a vital technology for addressing major surgical challenges. Nonetheless, several issues have yet to be overcome in terms of mechatronics, perception and surgeon-robot interfaces before microsurgical robots can achieve their full potential in operating rooms. Research in this direction is progressing quickly and microsurgery robot prototypes are gradually demonstrating significant clinical benefits in challenging applications such as reconstructive plastic surgery, ophthalmology, otology and laryngology. These are reassuring results offering confidence in a brighter future for high-precision surgical interventions.

  7. A method to discriminate solar and antisolar differential rotation in high-precision light curves

    CERN Document Server

    Reinhold, T

    2015-01-01

    Surface differential rotation (DR) is one major ingredient of the magnetic field generation process in the Sun and likely in other stars. The term solar-like differential rotation describes the observation that solar equatorial regions rotate faster than polar ones. The opposite effect of polar regions rotating faster than equatorial ones (termed as antisolar DR) has only been observed in a few stars, although there is evidence from theoretical dynamo models. We present a new method to detect the sign of DR (i.e. solar-like or antisolar DR) by analyzing long-term high-precision light curves with the Lomb-Scargle periodogram.We compute the Lomb-Scargle periodogram and identify a set of significant periods $P_k$, which we associate with active regions located at different latitudes on the the stellar surface. If detectable, the first harmonics ($P_k'$) of these periods were identified to compute their peak-height-ratios $r_k:=h(P_k')/h(P_k)$. Spots rotating at lower latitudes generate less sine-shaped light cur...

  8. A high-precision, distributed geodetic strainmeter based on dual coaxial cable Bragg gratings

    Science.gov (United States)

    Fu, J.; Wei, T.; Wei, M.; Shen, Y.

    2014-12-01

    Observations of surface deformation are essential for understanding a wide range of geophysical problems, including earthquakes, volcanoes, landslides, and glaciers. Current geodetic technologies, such as GPS, InSAR, borehole and laser strainmeters, are costly and limited in their temporal or spatial resolution. Here we present a new type of strainmeter based on coaxial cable Bragg grating (CCBG) sensing technology that provides high-precision, distributed strain measurements at a moderate cost. The coaxial-cable-based strainmeter is designed to cover a long distance (~ km) under harsh environmental conditions such as extreme temperatures. To minimize the environmental noises, two CCBGs are introduced into the geodetic strainmeter: one is used to measure the strain applied on it, and the other acts as a reference only to detect the environmental noises. The environmental noises are removed using the inputs from the strained CCBG and the reference CCBG in a frequency mixer. The test results show that the geodetic strainmeter with dual CCBGs has micron-strain accuracy in the lab.

  9. High precision mobile location framework and its service based on virtual reference station of GPS

    Science.gov (United States)

    Liu, Chun; Sun, Liangyu; Yao, Lianbi

    2008-10-01

    The wireless communication technology and space technology are synchronously developed in recent years, which bring up the development of location based service (LBS). At present, many location technology methods were developed. However, all these methods can only provide a relative poor location precision and depend on high cost. The technology of Virtual Reference Station (VRS) of GPS is then involved in this paper. One of the objective in this paper is aim to give the LBS position structure to improve the mobile location position when a mobile position instrument is connected with VRS network. The cheaper GPS built-in Personal Designer Aid (PDA) is then used to achieve a higher precision by using RTCM data from existing VRS network. In order to obtain a high precision position when using the low-cost GPS receiver as a rover, the infrusture of the mobile differential correction system is then put forward. According to network transportation of RTCM via internet protocol (NTRIP), the message is communicated through wireless network, such as GPRS, CDMA and so on. The rough coordinate information is sent to VRS control center continuously, and then the VRS correction information is replied to rover in the data format of RTCM3.1. So the position will be updated based on mathematic solution after the decoding of RTCM3.1 data. The thought of LBS position can improve the precision, and can speed the LBS.

  10. Identification of Error Sources in High Precision Weight Measurements of Gyroscopes

    CERN Document Server

    Lőrincz, I

    2015-01-01

    A number of weight anomalies have been reported in the past with respect to gyroscopes. Much attention was gained from a paper in Physical Review Letters, when Japanese scientists announced that a gyroscope loses weight up to $0.005\\%$ when spinning only in the clockwise rotation with the gyroscope's axis in the vertical direction. Immediately afterwards, a number of other teams tried to replicate the effect, obtaining a null result. It was suggested that the reported effect by the Japanese was probably due to a vibration artifact, however, no final conclusion on the real cause has been obtained. We decided to build a dedicated high precision setup to test weight anomalies of spinning gyroscopes in various configurations. A number of error sources like precession and vibration and the nature of their influence on the measurements have been clearly identified, which led to the conclusive explanation of the conflicting reports. We found no anomaly within $\\Delta m/m<2.6 \\times 10^{-6}$ valid for both horizon...

  11. High precision ultrasonic guided wave technique for inspection of power transmission line

    Science.gov (United States)

    Cheng, Jun; Qiu, Jinhao; Ji, Hongli; Wang, Enrong; Takagi, Toshiyuki; Uchimoto, Tetsuya

    2017-01-01

    Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave propagation in this structure is very complicated, leading to the unfavorable defect localization accuracy. Aiming at this situation, a high precision UGW technique for inspection of local surface defect in power transmission line is proposed. The technique is realized by adopting a novel segmental piezoelectric ring transducer and transducer mounting scheme, combining with the comprehensive characterization of wave propagation and circumferential defect positioning with multiple piezoelectric elements. Firstly, the propagation path of guided waves in the multi-wires of transmission line under the proposed technique condition is investigated experimentally. Next, the wave velocities are calculated by dispersion curves and experiment test respectively, and from comparing of the two results, the guided wave mode propagated in transmission line is confirmed to be F(1,1) mode. Finally, the axial and circumferential positioning of local defective wires in transmission line are both achieved, by using multiple piezoelectric elements to surround the stands and send elastic waves into every single wire. The proposed research can play a role of guiding the development of highly effective UGW method and detecting system for multi-wire transmission line.

  12. High-Precision CMOS Analog Computational Circuits Based on a New Linearly Tunable OTA

    Directory of Open Access Journals (Sweden)

    A. Naderi Saatlo

    2016-06-01

    Full Text Available Implementation of CMOS current-mode analog computational circuits are presented in this paper. A new Linearly Tunable OTA is employed in a modified structure as a basic building block for implementation of the circuits either linear or nonlinear functions. The proposed trans-conductance amplifier provides a constant Gm over a wide range of input voltage which allows the implementation of high precision computational circuits including square rooting, squaring, multiplication and division functions. Layout pattern of the proposed circuit confirms that the circuit can be implemented in 102μm*69μm active area. In order to verify the performance of the circuits, the post layout simulation results are presented through the use of HSPICE and Cadence with TSMC level 49 (BSIM3v3 parameters for 0.18 μm CMOS technology, where under supply voltage of 1.8 V, the maximum relative error of the circuits within 500 µA of input range is about 11 μA (2.2 % error and the THD remains as low as 1.2 % for the worst case. Moreover, the power dissipation of the complete structure is found to be 0.66 mW.

  13. High Precision Full Stokes Spectropolarimetry of the Sun as a star-Instrument design aspects

    CERN Document Server

    Bose, Souvik

    2016-01-01

    The magnetic field plays a major role in governing the dynamics of the sun. Many interesting features like sunspots, flares, prominences, and Coronal Mass Ejections (CMEs) occur on its surface due to the dynamics associated with the magnetic fields. The magnetic activity exhibits spatial scales ranging from very fine scale (below the resolution limit of the current largest telescope) to large scale such as sunspots, active regions and the spatial scales as large as the sun itself. While the major efforts in building large telescopes is going on towards the goal of resolving smallest structure possible we propose here to measure the magnetic field on the global scale. For this purpose we propose an instrument to carryout high precision and high accurate spectropolarimetry of sun-as-a-star. In this thesis, we explore various instrumental design aspects that are necessary to make such observations. As part of the design consideration we have analysed a major noise source i.e. seeing induced cross-talk through si...

  14. High-precision Detection of Facial Landmarks to Estimate Head Motions Based on Vision Models

    Directory of Open Access Journals (Sweden)

    Xiaohong W. Gao

    2007-01-01

    Full Text Available A new approach of determination of head movement is presented from the pictures recorded via digital cameras monitoring the scanning processing of PET. Two human vision models of CIECAMs and BMV are applied to segment the face region via skin colour and to detect local facial landmarks respectively. The developed algorithms are evaluated on the pictures (n=12 monitoring a subject’s head while simulating PET scanning captured by two calibrated cameras (located in the front and left side from a subject. It is shown that centers of chosen facial landmarks of eye corners and middle point of nose basement have been detected with very high precision (1 0.64 pixels. Three landmarks on pictures received by the front camera and two by the side camera have been identified. Preliminary results on 2D images with known moving parameters show that movement parameters of rotations and translations along X, Y, and Z directions can be obtained very accurately via the described methods.

  15. Next generation KATRIN high precision voltage divider for voltages up to 65kV

    CERN Document Server

    Bauer, S; Hochschulz, F; Ortjohann, H -W; Rosendahl, S; Thümmler, T; Schmidt, M; Weinheimer, C

    2013-01-01

    The KATRIN (KArlsruhe TRItium Neutrino) experiment aims to determine the mass of the electron antineutrino with a sensitivity of 200meV by precisely measuring the electron spectrum of the tritium beta decay. This will be done by the use of a retarding spectrometer of the MAC-E-Filter type. To achieve the desired sensitivity the stability of the retarding potential of -18.6kV has to be monitored with a precision of 3ppm over at least two months. Since this is not feasible with commercial devices, two ppm-class high voltage dividers were developed, following the concept of the standard divider for DC voltages of up to 100kV of the Physikalisch-Technische Bundesanstalt (PTB). In order to reach such high accuracies different effects have to be considered. The two most important ones are the temperature dependence of resistance and leakage currents, caused by insulators or corona discharges. For the second divider improvements were made concerning the high-precision resistors and the thermal design of the divider....

  16. A High-Precision NIR Survey for RV Variable Low-Mass Stars

    CERN Document Server

    Gagné, Jonathan; Gao, Peter; Anglada-Escude, Guillem; Furlan, Elise; Davison, Cassy; Tanner, Angelle; Henry, Todd J; Riedel, Adric R; Brinkworth, Carolyn; Latham, David; Bottom, Michael; White, Russel; Mills, Sean; Beichman, Chas; Johnson, John A; Ciardi, David R; Wallace, Kent; Mennesson, Bertrand; von Braun, Kaspar; Vasisht, Gautam; Prato, Lisa; Kane, Stephen R; Mamajek, Eric E; Walp, Bernie; Crawford, Timothy J; Rougeot, Raphaël; Geneser, Claire S; Catanzarite, Joseph

    2016-01-01

    We present the results of a precise near-infrared (NIR) radial velocity (RV) survey of 32 low-mass stars with spectral types K2-M4 using CSHELL at the NASA IRTF in the $K$-band with an isotopologue methane gas cell to achieve wavelength calibration and a novel iterative RV extraction method. We surveyed 14 members of young ($\\approx$ 25-150 Myr) moving groups, the young field star $\\varepsilon$ Eridani as well as 18 nearby ($<$ 25 pc) low-mass stars and achieved typical single-measurement precisions of 8-15 m s$^{-1}$ with a long-term stability of 15-50 m s$^{-1}$. We obtain the best NIR RV constraints to date on 27 targets in our sample, 19 of which were never followed by high-precision RV surveys. Our results indicate that very active stars can display long-term RV variations as low as $\\sim$ 25-50 m s$^{-1}$ at $\\approx$ 2.3125 $\\mu$m, thus constraining the effect of jitter at these wavelengths. We provide the first multi-wavelength confirmation of GJ 876 bc and independently retrieve orbital parameters...

  17. High Precision CTE-Measurement of SiC-100 for Cryogenic Space-Telescopes

    CERN Document Server

    Enya, K; Onaka, T; Nakagawa, T; Kaneda, H; Hirabayashi, M; Toulemont, Y; Castel, D; Kanai, Y; Fujishiro, N

    2007-01-01

    We present the results of high precision measurements of the thermal expansion of the sintered SiC, SiC-100, intended for use in cryogenic space-telescopes, in which minimization of thermal deformation of the mirror is critical and precise information of the thermal expansion is needed for the telescope design. The temperature range of the measurements extends from room temperature down to $\\sim$ 10 K. Three samples, #1, #2, and #3 were manufactured from blocks of SiC produced in different lots. The thermal expansion of the samples was measured with a cryogenic dilatometer, consisting of a laser interferometer, a cryostat, and a mechanical cooler. The typical thermal expansion curve is presented using the 8th order polynomial of the temperature. For the three samples, the coefficients of thermal expansion (CTE), $\\bar{\\alpha}_{#1}$, $\\bar{\\alpha}_{#2}$, and $\\bar{\\alpha}_{#3}$ were derived for temperatures between 293 K and 10 K. The average and the dispersion (1 $\\sigma$ rms) of these three CTEs are 0.816 an...

  18. GIARPS: the unique VIS-NIR high precision radial velocity facility in this world

    Science.gov (United States)

    Claudi, R.; Benatti, S.; Carleo, I.; Ghedina, A.; Molinari, E.; Oliva, E.; Tozzi, A.; Baruffolo, A.; Cecconi, M.; Cosentino, R.; Fantinel, D.; Fini, L.; Ghinassi, F.; Gonzalez, M.; Gratton, R.; Guerra, J.; Harutyunyan, A.; Hernandez, N.; Iuzzolino, M.; Lodi, M.; Malavolta, L.; Maldonado, J.; Micela, G.; Sanna, N.; Sanjuan, J.; Scuderi, S.; Sozzetti, A.; Pérez Ventura, H.; Diaz Marcos, H.; Galli, A.; Gonzalez, C.; Riverol, L.; Riverol, C.

    2016-08-01

    GIARPS (GIAno and haRPS) is a project devoted to have on the same focal station of the Telescopio Nazionale Galileo (TNG) both the high resolution spectrographs HARPS-N (VIS) and GIANO (NIR) working simultaneously. This could be considered the first and unique worldwide instrument providing cross-dispersed echelle spectroscopy at a high resolution (R=115,000 in the visual and R=50,000 in the IR) and over in a wide spectral range (0.383 - 2.45 μm) in a single exposure. The science case is very broad, given the versatility of such an instrument and the large wavelength range. A number of outstanding science cases encompassing mainly extra-solar planet science starting from rocky planet search and hot Jupiters, atmosphere characterization can be considered. Furthermore both instrument can measure high precision radial velocity by means the simultaneous thorium technique (HARPS - N) and absorbing cell technique (GIANO) in a single exposure. Other science cases are also possible. Young stars and proto- planetary disks, cool stars and stellar populations, moving minor bodies in the solar system, bursting young stellar objects, cataclysmic variables and X-ray binary transients in our Galaxy, supernovae up to gamma-ray bursts in the very distant and young Universe, can take advantage of the unicity of this facility both in terms of contemporaneous wide wavelength range and high resolution spectroscopy.

  19. Development and simulation of microfluidic Wheatstone bridge for high-precision sensor

    Science.gov (United States)

    Shipulya, N. D.; Konakov, S. A.; Krzhizhanovskaya, V. V.

    2016-08-01

    In this work we present the results of analytical modeling and 3D computer simulation of microfluidic Wheatstone bridge, which is used for high-accuracy measurements and precision instruments. We propose and simulate a new method of a bridge balancing process by changing the microchannel geometry. This process is based on the “etching in microchannel” technology we developed earlier (doi:10.1088/1742-6596/681/1/012035). Our method ensures a precise control of the flow rate and flow direction in the bridge microchannel. The advantage of our approach is the ability to work without any control valves and other active electronic systems, which are usually used for bridge balancing. The geometrical configuration of microchannels was selected based on the analytical estimations. A detailed 3D numerical model was based on Navier-Stokes equations for a laminar fluid flow at low Reynolds numbers. We investigated the behavior of the Wheatstone bridge under different process conditions; found a relation between the channel resistance and flow rate through the bridge; and calculated the pressure drop across the system under different total flow rates and viscosities. Finally, we describe a high-precision microfluidic pressure sensor that employs the Wheatstone bridge and discuss other applications in complex precision microfluidic systems.

  20. A high precision TDC based on a multi-phase clock

    CERN Document Server

    Qi, Zhong; Li, Deyuan; Yang, Lei; Yao, Zeen; Li, Dongcang

    2015-01-01

    The design of a high-precision time-to-digital converter (TDC) based on a multiphase clock implemented using a single field-programmable gate array is discussed in this paper. The TDC can increase the resolution of the measurement by using time interpolation. A phase-locked loop is used to generate four multiphase clocks whose frequencies are the same and whose phases are 0{\\deg}, 45{\\deg}, 90{\\deg}, and 135{\\deg}. In addition, the duty ratios of the four clocks are 50%. By utilizing four multiphase clocks to make up the interpolation clock, one clock period can be divided into eight uniform parts. The resolution of the TDC can be improved to 1/8 of a clock period. Furthermore, we have also designed a discriminator circuit for identifying the start and stop signals. On the basis of this circuit, the TDC can still measure the time interval of two signals when the start and stop signals are uncertain. The experimental results indicate that the time resolution of the TDC can achieve the theoretical value, and th...

  1. A high-precision finite element method for shock-tube calculations

    Science.gov (United States)

    Hughes, T. J. R.; Mallet, M.

    1985-01-01

    A two-pass explicit scheme is developed in order to exploit some of the capabilities of finite difference modeling (FDM) for finite element modeling (FEM), which offers the opportunity to account for any type of geometry in fluid flow modeling. Features of the first-order upwind and the Lax-Wendroff high precision explicit finite difference algorithms are reviewed. A flux limiter is developed for FEM to serve as an analog for the single limiter function which has been defined for the various FDMs. It is shown that an antidiffusive limiter must be introduced into the weighting function which normally multiplies the time-derivative term in the variational equation. The two-pass scheme which results is demonstrated to be the equivalent of FDMs with five-point support. However, the present scheme is valid only for one-dimensional calculations and linear shape functions for shock tube flow phenomena. Further work is required for its use with nonlinear hyperbolic systems.

  2. An Online Gravity Modeling Method Applied for High Precision Free-INS.

    Science.gov (United States)

    Wang, Jing; Yang, Gongliu; Li, Jing; Zhou, Xiao

    2016-09-23

    For real-time solution of inertial navigation system (INS), the high-degree spherical harmonic gravity model (SHM) is not applicable because of its time and space complexity, in which traditional normal gravity model (NGM) has been the dominant technique for gravity compensation. In this paper, a two-dimensional second-order polynomial model is derived from SHM according to the approximate linear characteristic of regional disturbing potential. Firstly, deflections of vertical (DOVs) on dense grids are calculated with SHM in an external computer. And then, the polynomial coefficients are obtained using these DOVs. To achieve global navigation, the coefficients and applicable region of polynomial model are both updated synchronously in above computer. Compared with high-degree SHM, the polynomial model takes less storage and computational time at the expense of minor precision. Meanwhile, the model is more accurate than NGM. Finally, numerical test and INS experiment show that the proposed method outperforms traditional gravity models applied for high precision free-INS.

  3. High-precision satellite relative-trajectory simulating servosystem for inter-satellite laser communications

    Science.gov (United States)

    Zhang, Lei; Liu, Liren; Luan, Zhu; Liu, Hongzhan; Xu, Rongwei

    2004-10-01

    Because PAT (pointing-acquisition-tracking) parameters and integrated technical specifications of laser communication terminals for inter-satellite link must be pre-verified and assessed thoroughly on a ground-based test-bed before launched into the space, it is necessary to develop a system as a primary part of the test bed to simulate the relative trajectory between the satellites. In this paper, an original high-precision satellite relative-trajectory simulating servosystem is introduced in detail as well as its structures and characteristics. The system is used to simulate the motion of relative-trajectory between satellites in different orbits. The principle of the system is to import the data of two satellites" orbits into a computer-based control system in advance. After processed and analyzed, the data is transformed into the angular displacement of the servomotor which drives the gimbal directly. The angular displacement of the two axes of the gimbal can simulate precisely the relative-trajectory, namely elevation angle and azimuth angle of the two satellites in communication. A laser communication terminal mounted on the gimbal then performs the PAT mechanisms to evaluate the system"s capacity.

  4. A high precision high PSRR bandgap reference with thermal hysteresis protection

    Energy Technology Data Exchange (ETDEWEB)

    Yang Yintang; Li Yani; Zhu Zhangming, E-mail: yanili@mail.xidian.edu.c [Key Laboratory of Wide Band-Gap Semiconductor Materials and Devices of the Ministry of Education, Institute of Microelectronics, Xidian University, Xi' an 710071 (China)

    2010-09-15

    To meet the accuracy requirement for the bandgap voltage reference by the increasing data conversion precision of integrated circuits, a high-order curvature-compensated bandgap voltage reference is presented employing the characteristic of bipolar transistor current gain exponentially changing with temperature variations. In addition, an over-temperature protection circuit with a thermal hysteresis function to prevent thermal oscillation is proposed. Based on the CSMC 0.5 {mu}m 20 V BCD process, the designed circuit is implemented; the active die area is 0.17 x 0.20 mm{sup 2}. Simulation and testing results show that the temperature coefficient is 13.7ppm/K with temperature ranging from -40 to 150 {sup 0}C, the power supply rejection ratio is -98.2 dB, the line regulation is 0.3 mV/V, and the power consumption is only 0.38 mW. The proposed bandgap voltage reference has good characteristics such as small area, low power consumption, good temperature stability, high power supply rejection ratio, as well as low line regulation. This circuit can effectively prevent thermal oscillation and is suitable for on-chip voltage reference in high precision analog, digital and mixed systems. (semiconductor integrated circuits)

  5. Maintaining high precision of isotope ratio analysis over extended periods of time.

    Science.gov (United States)

    Brand, Willi A

    2009-06-01

    Stable isotope ratios are reliable and long lasting process tracers. In order to compare data from different locations or different sampling times at a high level of precision, a measurement strategy must include reliable traceability to an international stable isotope scale via a reference material (RM). Since these international RMs are available in low quantities only, we have developed our own analysis schemes involving laboratory working RM. In addition, quality assurance RMs are used to control the long-term performance of the delta-value assignments. The analysis schemes allow the construction of quality assurance performance charts over years of operation. In this contribution, the performance of three typical techniques established in IsoLab at the MPI-BGC in Jena is discussed. The techniques are (1) isotope ratio mass spectrometry with an elemental analyser for delta(15)N and delta(13)C analysis of bulk (organic) material, (2) high precision delta(13)C and delta(18)O analysis of CO(2) in clean-air samples, and (3) stable isotope analysis of water samples using a high-temperature reaction with carbon. In addition, reference strategies on a laser ablation system for high spatial resolution delta(13)C analysis in tree rings is exemplified briefly.

  6. Development of a High-Precision Touch-Trigger Probe Using a Single Sensor

    Directory of Open Access Journals (Sweden)

    Rui-Jun Li

    2016-03-01

    Full Text Available To measure various components with nano-scale precision, a new high-precision touch-trigger probe using a single low-cost sensor for a micro-coordinate measuring machine (CMM is presented in this paper. The sensor is composed of a laser diode, a plane mirror, a focusing lens, and a quadrant photo detector (QPD. The laser beam from the laser diode with an incident angle is reflected by the plane mirror and then projected onto the quadrant photo detector (QPD via the focusing lens. The plane mirror is adhered to the upper surface of the floating plate supported by an elastic mechanism, which can transfer the displacement of the stylus’s ball tip in 3D to the plane mirror’s vertical and tilt movement. Both motions of the plane mirror can be detected by respective QPDs. The probe mechanism was analyzed, and its structural parameters that conform to the principle of uniform sensitivity and uniform stiffness were obtained. The simulation result showed that the stiffness was equal in 3D and less than 1 mN/µm. Some experiments were performed to investigate the probe’s characteristics. It was found that the probe could detect the trigger point with uniform sensitivity, a resolution of less than 5 nm, and a repeatability of less than 4 nm. It can be used as a touch-trigger probe on a micro/nano-CMM.

  7. High-precision CTE measurement of hybrid C/SiC composite for cryogenic space telescopes

    CERN Document Server

    Enya, K; Imai, T; Tange, Y; Kaneda, H; Katayama, H; Kotani, M; Maruyama, K; Naitoh, M; Nakagawa, T; Onaka, T; Suganuma, M; Ozaki, T; Kume, M; Krodel, M R

    2011-01-01

    This paper presents highly precise measurements of thermal expansion of a "hybrid" carbon-fiber reinforced silicon carbide composite, HB-Cesic\\textregistered - a trademark of ECM, in the temperature region of \\sim310-10K. Whilst C/SiC composites have been considered to be promising for the mirrors and other structures of space-borne cryogenic telescopes, the anisotropic thermal expansion has been a potential disadvantage of this material. HB-Cesic\\textregistered is a newly developed composite using a mixture of different types of chopped, short carbon-fiber, in which one of the important aims of the development was to reduce the anisotropy. The measurements indicate that the anisotropy was much reduced down to 4% as a result of hybridization. The thermal expansion data obtained are presented as functions of temperature using eighth-order polynomials separately for the horizontal (XY-) and vertical (Z-) directions of the fabrication process. The average CTEs and their dispersion (1{\\sigma}) in the range 293-10...

  8. A novel low-voltage high precision current reference based on subthreshold MOSFETs

    Institute of Scientific and Technical Information of China (English)

    YU Guo-yi; ZOU Xue-cheng

    2007-01-01

    A novel topology low-voltage high precision current reference based on subthreshold Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs) is presented. The circuit achieves a temperature-independent reference current by a proper combination current of two first-order temperature-compensation current References , which exploit the temperature characteristics of integrated poly2 resistors and the Ⅰ- Ⅴ transconductance characteristics of MOSFET operating in the subthreshold region. The circuit, designed with the 1st silicon 0.35 μm standard CMOS logic process technology, exhibits a stable current of about 2.25 μA with much low temperature coefficient of 3 ×10-4 μA/℃ in the temperature range of -40~150 ℃ at 1 V supply voltage, and also achieves a better power supply rejection ratio (PSRR) over a broad frequency. The PSRR is about -78 dB at DC and remains -42dB at the frequency higher than 10 MHz. The maximal process error is about 6.7% based on the Monte Carlo simulation. So it has good process compatibility.

  9. High-precision astrometry with VVV. I. An independent reduction pipeline for VIRCAM@VISTA

    CERN Document Server

    Libralato, M; Bedin, L R; Anderson, J; Piotto, G; Nascimbeni, V; Platais, I; Minniti, D; Zoccali, M

    2015-01-01

    We present a new reduction pipeline for the VIRCAM@VISTA detector and describe the method developed to obtain high-precision astrometry with the VISTA Variables in the V\\'ia L\\'actea (VVV) data set. We derive an accurate geometric-distortion correction using as calibration field the globular cluster NGC 5139, and showed that we are able to reach a relative astrometric precision of about 8 mas per coordinate per exposure for well-measured stars over a field of view of more than 1 square degree. This geometric-distortion correction is made available to the community. As a test bed, we chose a field centered around the globular cluster NGC 6656 from the VVV archive and computed proper motions for the stars within. With 45 epochs spread over four years, we show that we are able to achieve a precision of 1.4 mas/yr and to isolate each population observed in the field (cluster, Bulge and Disk) using proper motions. We used proper-motion-selected field stars to measure the motion difference between Galactic disk and...

  10. LEBIT II: Upgrades and developments for high precision Penning trap mass measurements with rare isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Redshaw, M., E-mail: redsh1m@cmich.edu [Department of Physics, Central Michigan University, Mount Pleasant, MI 48859 (United States); Bollen, G.; Bustabad, S.; Kwiatkowski, A.A.; Lincoln, D.L.; Novario, S.J. [National Superconducting Cyclotron Laboratory, East Lansing, MI 48224 (United States); Department of Physics, Michigan State University, East Lansing, MI 48224 (United States); Ringle, R.; Schwarz, S. [National Superconducting Cyclotron Laboratory, East Lansing, MI 48224 (United States); Valverde, A.A. [National Superconducting Cyclotron Laboratory, East Lansing, MI 48224 (United States); Department of Physics, Michigan State University, East Lansing, MI 48224 (United States)

    2013-12-15

    Highlights: • Development and implementation of new experimental techniques at the Low Energy Beam and Ion Trap (LEBIT) facility at the National Superconducting Cyclotron Laboratory (NSCL). • Development of a laser ablation ion source for the production of carbon clusters for use as mass references and stable isotopes for offline mass measurement programs. • Implementation of stored waveform inverse Fourier transform (SWIFT) for efficient removal of contaminant ions. • Development of a miniature Penning trap to be installed in the LEBIT magnet and used as a magnetometer for monitoring temporal variations in the magnetic field strength. • Development of a new 7 T single-ion Penning trap (SIPT) at the NSCL that will use image charge detection for ultra-high sensitivity measurements of short-lived rare isotopes with very low production rates. -- Abstract: During the next several years and decades the extension of high-precision Penning trap mass spectrometry measurements to more-exotic isotopes, lying far from the valley of stability will continue to provide significant contributions to nuclear physics. However, such measurements must overcome the challenges of working with isotopes that have low production rates and short lifetimes. At the Low Energy Beam and Ion Trap (LEBIT) facility at the National Superconducting Cyclotron Laboratory, a number of developments have been implemented or are underway to meet these challenges by minimizing rare-isotope preparation and measurement time, maximizing use of available beam time, and increasing sensitivity. These developments and the current status of the LEBIT facility will be discussed.

  11. High-precision measurement of the X-ray Cu Kα spectrum.

    Science.gov (United States)

    Mendenhall, Marcus H; Henins, Albert; Hudson, Lawrence T; Szabo, Csilla I; Windover, Donald; Cline, James P

    2017-06-01

    The structure of the X-ray emission lines of the Cu Kα complex has been remeasured on a newly commissioned instrument, in a manner directly traceable to the Système Internationale definition of the meter. In this measurement, the region from 8000 eV to 8100 eV has been covered with a highly precise angular scale, and well-defined system efficiency, providing accurate wavelengths and relative intensities. This measurement updates the standard multi-Lorentzian-fit parameters from Härtwig, Hölzer, et al., and is in modest disagreement with their results for the wavelength of the Kα1 line when compared via quadratic fitting of the peak top; the intensity ratio of Kα1 to Kα2 agrees within the combined error bounds. However, the position of the fitted top of Kα1 is very sensitive to the fit parameters, so it is not believed to be a robust value to quote without further qualification. We also provide accurate intensity and wavelength information for the so-called Kα3,4 "satellite" complex. Supplementary data is provided which gives the entire shape of the spectrum in this region, allowing it to be used directly in cases where simplified, multi-Lorentzian fits to it are not sufficiently accurate.

  12. b-CGC versus IP-Sat and high precision combined HERA data

    CERN Document Server

    Rezaeian, Amir H

    2014-01-01

    The Impact-Parameter dependent Color Glass Condensate (b-CGC) and Saturation (IP-Sat) dipole models incorporate key features of small-x physics properties and match smoothly to the perturbative QCD regime at large $Q^2$ for a given $x$. Although both models include saturation effects and depend on impact-parameter, the former is based on the non-linear BK equation, while the latter is based on DGLAP evolution. After confronting the models to the recently released high precision combined HERA data, we show that in both models, the typical impact-parameter probed in the total $\\gamma^{*}p$ cross-section is about $b\\approx 2\\div 3\\,\\text{GeV}^{-1}$ and the proton saturation scale is $Q_S<1$ GeV in HERA kinematics. We show that most features of inclusive DIS and exclusive diffractive data at HERA are correctly reproduced in both models. Nevertheless, the b-CGC and the IP-Sat models give significantly different predictions beyond the current HERA kinematics for the structure functions at very low x and high vir...

  13. High-precision timing of 42 millisecond pulsars with the European Pulsar Timing Array

    CERN Document Server

    Desvignes, G; Lentati, L; Verbiest, J P W; Champion, D J; Stappers, B W; Janssen, G H; Lazarus, P; Osłowski, S; Babak, S; Bassa, C G; Brem, P; Burgay, M; Cognard, I; Gair, J R; Graikou, E; Guillemot, L; Hessels, J W T; Jessner, A; Jordan, C; Karuppusamy, R; Kramer, M; Lassus, A; Lazaridis, K; Lee, K J; Liu, K; Lyne, A G; McKee, J; Mingarelli, C M F; Perrodin, D; Petiteau, A; Possenti, A; Purver, M B; Rosado, P A; Sanidas, S; Sesana, A; Shaifullah, G; Smits, R; Taylor, S R; Theureau, G; Tiburzi, C; van Haasteren, R; Vecchio, A

    2016-01-01

    We report on the high-precision timing of 42 radio millisecond pulsars (MSPs) observed by the European Pulsar Timing Array (EPTA). This EPTA Data Release 1.0 extends up to mid-2014 and baselines range from 7-18 years. It forms the basis for the stochastic gravitational-wave background, anisotropic background, and continuous-wave limits recently presented by the EPTA elsewhere. The Bayesian timing analysis performed with TempoNest yields the detection of several new parameters: seven parallaxes, nine proper motions and, in the case of six binary pulsars, an apparent change of the semi-major axis. We find the NE2001 Galactic electron density model to be a better match to our parallax distances (after correction from the Lutz-Kelker bias) than the M2 and M3 models by Schnitzeler (2012). However, we measure an average uncertainty of 80\\% (fractional) for NE2001, three times larger than what is typically assumed in the literature. We revisit the transverse velocity distribution for a set of 19 isolated and 57 bina...

  14. Scanning near-field lithography with high precision flexure orientation stage control

    Science.gov (United States)

    Qin, Jin; Zhang, Liang; Tan, Haosen; Wang, Liang

    2017-09-01

    A new design of an orientation stage for scanning near-field lithography is presented based on flexure hinges. Employing flexure mechanisms in place of rigid-body mechanisms is one of the most promising techniques to efficiently implement high precision motion and avoid problems caused by friction. For near-field scanning lithography with evanescent wave, best resolution can be achieved in contact mode. However, if the mask is fixed on a rigid stage, contact friction will deteriorate the lithography surface. To reduce friction while maintaining good contact between the mask and the substrate, the mask should be held with high lateral stiffness and low torsion stiffness. This design can hold the mask in place during the scanning process and achieve passive alignment. Circular flexure hinges, whose parameters are determined by motion requirements based on Schotborgh's equation, are used as the basic unit of the stage to achieve passive alignment by compensating motions from elastic deformation. A finite-element analysis is performed to verify this property of the stage. With the aid of this stage, 21 nm resolution is achieved in static near-field lithography and 18 nm line-width in scanning near-field lithography.

  15. High-precision radiocarbon dating and historical biblical archaeology in southern Jordan.

    Science.gov (United States)

    Levy, Thomas E; Higham, Thomas; Bronk Ramsey, Christopher; Smith, Neil G; Ben-Yosef, Erez; Robinson, Mark; Münger, Stefan; Knabb, Kyle; Schulze, Jürgen P; Najjar, Mohammad; Tauxe, Lisa

    2008-10-28

    Recent excavations and high-precision radiocarbon dating from the largest Iron Age (IA, ca. 1200-500 BCE) copper production center in the southern Levant demonstrate major smelting activities in the region of biblical Edom (southern Jordan) during the 10th and 9th centuries BCE. Stratified radiocarbon samples and artifacts were recorded with precise digital surveying tools linked to a geographic information system developed to control on-site spatial analyses of archaeological finds and model data with innovative visualization tools. The new radiocarbon dates push back by 2 centuries the accepted IA chronology of Edom. Data from Khirbat en-Nahas, and the nearby site of Rujm Hamra Ifdan, demonstrate the centrality of industrial-scale metal production during those centuries traditionally linked closely to political events in Edom's 10th century BCE neighbor ancient Israel. Consequently, the rise of IA Edom is linked to the power vacuum created by the collapse of Late Bronze Age (LB, ca. 1300 BCE) civilizations and the disintegration of the LB Cypriot copper monopoly that dominated the eastern Mediterranean. The methodologies applied to the historical IA archaeology of the Levant have implications for other parts of the world where sacred and historical texts interface with the material record.

  16. New high-precision 40Ar/39Ar ages on Oligocene volcanic rocks of northwestern Kenya

    Science.gov (United States)

    Brown, Francis H.; Jicha, Brian R.

    2016-02-01

    New, high-precision 40Ar/39Ar ages from volcanic rocks in northwestern Kenya are provided for some areas of exposure in this remote area. We report seven 40Ar/39Ar ages generated from single crystal total fusion experiments on alkali feldspar separated from volcanic rocks in the Mogila, Songot, and Lokwanamur Ranges and the Gatome valley. A rhyolite from the lower part of the sequence in the Mogila Range yielded ages of 32.31 ± 0.06 Ma and 32.33 ± 0.07 Ma, and a rhyolite near the top of that sequence yielded 31.67 ± 0.04 Ma. A single sample from the Songot Range yielded an age of 32.49 ± 0.07 Ma, slightly older than the rocks collected from Mogila. In both ranges the early Oligocene rhyolites are underlain by basalts, as is also the case in the Labur Range. Ages of 25.95 ± 0.03 Ma, 25.91 ± 0.04 Ma, and 27.15 ± 0.03 Ma were measured on alkali feldspar from rhyolites from the Lokwanamur Range, and the nearby Gatome valley. All of these rocks are part of an episode of widespread volcanism in northwestern Kenya in the mid-to late Oligocene that is not currently known from the Ethiopian Rift Valley.

  17. Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines

    Energy Technology Data Exchange (ETDEWEB)

    Pauluhn, Anuschka, E-mail: anuschka.pauluhn@psi.ch; Pradervand, Claude; Rossetti, Daniel; Salathe, Marco; Schulze-Briese, Clemens [Paul Scherrer Institut, CH-5232 Villigen (Switzerland)

    2011-07-01

    An automated loop-centring program and a high-precision goniometer head used at the Swiss Light Source are described. Automatic loop centring has been developed as part of the automation process in crystallographic data collection at the Swiss Light Source. The procedure described here consists of an optional set-up part, in which the background images are taken, and the actual centring part. The algorithm uses boundary and centre-of-mass detection at two different microscope image magnifications. Micromounts can be handled as well. Centring of the loops can be achieved in 15–26 s, depending on their initial position, and as fast as manual centring. The alignment of the sample is carried out by means of a new flexural-hinge-based compact goniometer head. The device features an electromagnet for robotic wet mounting of samples. The circle of confusion was measured to be smaller than 1 µm (r.m.s.); its bidirectional backlash is below 2 µm.

  18. Fixed energy balance window quench correction for high precision LSC {sup 14}C dating

    Energy Technology Data Exchange (ETDEWEB)

    Tudyka, Konrad, E-mail: konrad.tudyka@polsl.pl [GADAM Centre of Excellence Gliwice Absolute Dating Methods Centre, Silesian University of Technology, Krzywoustego 2, 44-100 Gliwice (Poland); Pawlyta, Jacek; Pazdur, Anna [GADAM Centre of Excellence Gliwice Absolute Dating Methods Centre, Silesian University of Technology, Krzywoustego 2, 44-100 Gliwice (Poland)

    2011-10-15

    In this paper we present the new LSC spectra evaluation method for high precision {sup 14}C dating with Quantulus 1220{sup TM}. The generally used fixed window is replaced with the fixed energy balanced counting window. The lower and upper channel of the window in the multichannel analyzer vary according to the quench level of each individual measurement. The position of the window is determined with the external standard quench parameter SQP(E) of Quantulus 1220{sup TM}. We show how this fixed energy balance window for each sample secures high stability and reduced quench correction. This method is compared with the typically used fixed channel window. - Highlights: > In this paper we present the new LSC spectra evaluation method. > We show how to setup fixed energy balance window. > The lower and upper channel of the window vary according to the quench level of each individual measurement. > We show how fixed energy balance window secures high stability. > We show the benefits of the fixed energy balance window.

  19. Rapid fabrication of a poly(dimethylsiloxane) microfluidic capillary gel electrophoresis system utilizing high precision machining.

    Science.gov (United States)

    Zhao, Dong S; Roy, Binayak; McCormick, Matthew T; Kuhr, Werner G; Brazill, Sara A

    2003-05-01

    In this work, we demonstrate a rapid protocol to address one of the major barriers that exists in the fabrication of chip devices, creating the micron-sized structures in the substrate material. This approach makes it possible to design, produce, and fabricate a microfluidic system with channel features >10 microm in poly(dimethylsiloxane)(PDMS) in under 8 hours utilizing instrumentation common to most machine shops. The procedure involves the creation of a master template with negative features, using high precision machining. This master is then employed to create an acrylic mold that is used in the final fabrication step to cast channel structures into the PDMS substrate. The performance of the microfluidic system prepared using this fabrication procedure is evaluated by constructing a miniaturized capillary gel electrophoresis (micro-CGE) system for the analysis of DNA fragments. Agarose is utilized as the sieving medium in the micro-CGE device and is shown to give reproducible (RSD (n= 34) approximately 5.0%) results for about 34 individual separations without replenishing the gel. To demonstrate the functionality of the micro-CGE device, a DNA restriction ladder (spanning 26-700 base pairs) and DNA fragments generated by PCR are separated and detected with laser-induced fluorescence (LIF). The microchip is shown to achieve a separation efficiency of 2.53 x 10(5) plates m(-1).

  20. Measurement device for high-precision spectral transmittance of solar blind filter

    Science.gov (United States)

    Wang, Yan; Qian, Yunsheng; Lv, Yang; Feng, Cheng; Liu, Jian

    2017-02-01

    In order to measure spectral transmittance of solar-blind filter ranging from ultraviolet to visible light accurately, a high-precision filter transmittance measuring system based on the ultraviolet photomultiplier is developed. The calibration method is mainly used to measure transmittance in this system, which mainly consists of an ultraviolet photomultiplier as core of the system and a lock-in amplifier combined with an optical modulator as the aided measurement for the system. The ultraviolet photomultiplier can amplify the current signal through the filter and have the characteristics of low dark current and high luminance gain. The optical modulator and the lock-in amplifier can obtain the signal from the photomultiplier and inhibit dark noise and spurious signal effectively. Through these two parts, the low light passing through the filters can be detected and we can calculate the transmittance by the optical power detected. Based on the proposed system, the limit detection of the transmittance can reach 10-12, while the result of the conventional approach is merely 10-6. Therefore, the system can make an effective assessment of solar blind ultraviolet filters.

  1. High-precision gamma-ray spectroscopy for enhancing production and application of medical isotopes

    Science.gov (United States)

    McCutchan, E. A.; Sonzogni, A. A.; Smith, S. V.; Muench, L.; Nino, M.; Greene, J. P.; Carpenter, M. P.; Zhu, S.; Chillery, T.; Chowdhury, P.; Harding, R.; Lister, C. J.

    2015-10-01

    Nuclear medicine is a field which requires precise decay data for use in planning radionuclide production and in imaging and therapeutic applications. To address deficiencies in decay data, sources of medical isotopes were produced and purified at the Brookhaven Linear Isotope Producer (BLIP) then shipped to Argonne National Laboratory where high-precision, gamma-ray measurements were performed using Gammasphere. New decay schemes for a number of PET isotopes and the impact on dose calculations will be presented. To investigate the production of next-generation theranostic or radiotherapeutic isotopes, cross section measurements with high energy protons have also been explored at BLIP. The 100-200 MeV proton energy regime is relatively unexplored for isotope production, thus offering high discovery potential but at the same time a challenging analysis due to the large number of open channels at these energies. Results of cross sections deduced from Compton-suppressed, coincidence gamma-ray spectroscopy performed at Lowell will be presented, focusing on the production of platinum isotopes by irradiating natural platinum foils with 100 to 200 MeV protons. DOE Isotope Program is acknowledged for funding ST5001030. Work supported by the US DOE under Grant DE-FG02-94ER40848 and Contracts DE-AC02-98CH10946 and DE-AC02-06CH11357.

  2. Development of an ultra high-precision x-ray telescope with an adaptive optics system

    Science.gov (United States)

    Kitamoto, Shunji; Takano, Haruko; Saitoh, Harue; Yamamoto, Norimasa; Kohmura, Takayoshi; Suga, Kazuharu; Sekiguchi, Hiroyuki

    2003-06-01

    We are developing an ultra high precision Soft X-ray telescope. The design of the telescope is a normal incident one for 13.5 nm band using Mo/Si multilayers. Two ideas are introduced. One is the optical measurement system in order to monitor the prevision of the optics system. The other is the adaptive optics system with a deformable mirror. Using an x-ray optical separation filter, we can always monitor the deformation of the optics by optical light. With this information, we can control the deformable mirror to compensate the system deformation as a closed loop system. We confirmed that the absolute precision of the wave front sensor was less than 3 nm rms. The preicison of the deformable mirror was roughly 5 nm rms. The shape of the primary mirror was an off-axis paraboloide with an effective diameter of 80mm. This primary mirror was coated by Mo/Si multilayers. The reflectivity of the primary mirror at 13.5 nm was rnaging from 30 to 50%. The x-ray optical separation filter was made from Zr with a thicknness of ~170nm. The transmission of the filter for low energy x-ray was measured and was roughly 50% at 13.5nm.

  3. High-precision optical systems with inexpensive hardware: a unified alignment and structural design approach

    Science.gov (United States)

    Winrow, Edward G.; Chavez, Victor H.

    2011-09-01

    High-precision opto-mechanical structures have historically been plagued by high costs for both hardware and the associated alignment and assembly process. This problem is especially true for space applications where only a few production units are produced. A methodology for optical alignment and optical structure design is presented which shifts the mechanism of maintaining precision from tightly toleranced, machined flight hardware to reusable, modular tooling. Using the proposed methodology, optical alignment error sources are reduced by the direct alignment of optics through their surface retroreflections (pips) as seen through a theodolite. Optical alignment adjustments are actualized through motorized, sub-micron precision actuators in 5 degrees of freedom. Optical structure hardware costs are reduced through the use of simple shapes (tubes, plates) and repeated components. This approach produces significantly cheaper hardware and more efficient assembly without sacrificing alignment precision or optical structure stability. The design, alignment plan and assembly of a 4" aperture, carbon fiber composite, Schmidt-Cassegrain concept telescope is presented.

  4. A high precision visual localization sensor and its working methodology for an indoor mobile robot

    Institute of Scientific and Technical Information of China (English)

    Feng-yu ZHOU; Xian-feng YUAN; Yang YANG; Zhi-fei JIANG; Chen-lei ZHOU

    2016-01-01

    To overcome the shortcomings of existing robot localization sensors, such as low accuracy and poor robustness, a high precision visual localization system based on infrared-reflective artificial markers is designed and illustrated in detail in this paper. First, the hardware system of the localization sensor is developed. Secondly, we design a novel kind of infrared-reflective artificial marker whose characteristics can be extracted by the acquisition and processing of the infrared image. In addition, a confidence calculation method for marker identification is proposed to obtain the probabilistic localization results. Finally, the autonomous localization of the robot is achieved by calculating the relative pose relation between the robot and the artificial marker based on the perspective-3-point (P3P) visual localization algorithm. Numerous experiments and practical applications show that the designed localization sensor system is immune to the interferences of the illumination and observation angle changes. The precision of the sensor is ±1.94 cm for position localization and ±1.64◦ for angle localization. Therefore, it satisfies perfectly the requirements of localization precision for an indoor mobile robot.

  5. Establishment of high-precision navigation system in the Republic of Armenia

    Directory of Open Access Journals (Sweden)

    Manukyan Larisa Vladimirovna

    2015-04-01

    Full Text Available Medium-Earth orbit satellite systems make it possible to provide services on time coordination and navigation support for a wide range of consumers. At present, there are global navigation satellite systems GLONASS (Russia and GPS (USA. Users of these systems have an opportunity to determine their location accurately with the given characteristics of their navigation devices. In all developed countries the progress of geodesy and cartography is closely related to the implementation of advanced new technologies in both scientific and industrial areas. The introduction of new technologies and equipment in production is essential for the development of geodesy and cartography, bringing the existing geodetic networks and cartographic materials to modern condition. In the Republic of Armenia there are also plans on introduction of the systems for monitoring and management of vehicles for various purposes, as well as it is proposed to establish and implement an effective satellite navigation system to monitor and control traffic on the basis of advanced satellite technology. The article describes the basic steps to create the network of reference stations, GPS, aerial photography of much of the territory of Armenia, the creation of digital terrain model and the new maps by orthophotoplans. The analysis of the materials were carried out, on the basis of which in the Republic in 2015 a high-precision navigation system will be created. Due to the hard work of surveyors, cartographers and topographers the Republic was brought to European states level.

  6. Fully stabilized mid-infrared frequency comb for high-precision molecular spectroscopy.

    Science.gov (United States)

    Vainio, Markku; Karhu, Juho

    2017-02-20

    A fully stabilized mid-infrared optical frequency comb spanning from 2.9 to 3.4 µm is described in this article. The comb is based on half-harmonic generation in a femtosecond optical parametric oscillator, which transfers the high phase coherence of a fully stabilized near-infrared Er-doped fiber laser comb to the mid-infrared region. The method is simple, as no phase-locked loops or reference lasers are needed. Precise locking of optical frequencies of the mid-infrared comb to the pump comb is experimentally verified at sub-20 mHz level, which corresponds to a fractional statistical uncertainty of 2 × 10-16 at the center frequency of the mid-infrared comb. The fully stabilized mid-infrared comb is an ideal tool for high-precision molecular spectroscopy, as well as for optical frequency metrology in the mid-infrared region, which is difficult to access with other stabilized frequency comb techniques.

  7. SEMICONDUCTOR INTEGRATED CIRCUITS: A high precision high PSRR bandgap reference with thermal hysteresis protection

    Science.gov (United States)

    Yintang, Yang; Yani, Li; Zhangming, Zhu

    2010-09-01

    To meet the accuracy requirement for the bandgap voltage reference by the increasing data conversion precision of integrated circuits, a high-order curvature-compensated bandgap voltage reference is presented employing the characteristic of bipolar transistor current gain exponentially changing with temperature variations. In addition, an over-temperature protection circuit with a thermal hysteresis function to prevent thermal oscillation is proposed. Based on the CSMC 0.5 μm 20 V BCD process, the designed circuit is implemented; the active die area is 0.17 × 0.20 mm2. Simulation and testing results show that the temperature coefficient is 13.7ppm/K with temperature ranging from -40 to 150 °C, the power supply rejection ratio is -98.2 dB, the line regulation is 0.3 mV/V, and the power consumption is only 0.38 mW. The proposed bandgap voltage reference has good characteristics such as small area, low power consumption, good temperature stability, high power supply rejection ratio, as well as low line regulation. This circuit can effectively prevent thermal oscillation and is suitable for on-chip voltage reference in high precision analog, digital and mixed systems.

  8. THE APPLICATION OF MULTIVIEW METHODS FOR HIGH-PRECISION ASTROMETRIC SPACE VLBI AT LOW FREQUENCIES

    Energy Technology Data Exchange (ETDEWEB)

    Dodson, R.; Rioja, M.; Imai, H. [International Centre for Radio Astronomy Research, M468, University of Western Australia, 35 Stirling Hwy, Crawley, Western Australia 6009 (Australia); Asaki, Y. [Institute of Space and Astronautical Science, 3-1-1 Yoshinodai, Chuou, Sagamihara, Kanagawa 252-5210 (Japan); Hong, X.-Y.; Shen, Z., E-mail: richard.dodson@icrar.org [Shanghai Astronomical Observatory, CAS, 200030 Shanghai (China)

    2013-06-15

    High-precision astrometric space very long baseline interferometry (S-VLBI) at the low end of the conventional frequency range, i.e., 20 cm, is a requirement for a number of high-priority science goals. These are headlined by obtaining trigonometric parallax distances to pulsars in pulsar-black hole pairs and OH masers anywhere in the Milky Way and the Magellanic Clouds. We propose a solution for the most difficult technical problems in S-VLBI by the MultiView approach where multiple sources, separated by several degrees on the sky, are observed simultaneously. We simulated a number of challenging S-VLBI configurations, with orbit errors up to 8 m in size and with ionospheric atmospheres consistent with poor conditions. In these simulations we performed MultiView analysis to achieve the required science goals. This approach removes the need for beam switching requiring a Control Moment Gyro, and the space and ground infrastructure required for high-quality orbit reconstruction of a space-based radio telescope. This will dramatically reduce the complexity of S-VLBI missions which implement the phase-referencing technique.

  9. High Precision Ranging and Range-Rate Measurements over Free-Space-Laser Communication Link

    Science.gov (United States)

    Yang, Guangning; Lu, Wei; Krainak, Michael; Sun, Xiaoli

    2016-01-01

    We present a high-precision ranging and range-rate measurement system via an optical-ranging or combined ranging-communication link. A complete bench-top optical communication system was built. It included a ground terminal and a space terminal. Ranging and range rate tests were conducted in two configurations. In the communication configuration with 622 data rate, we achieved a two-way range-rate error of 2 microns/s, or a modified Allan deviation of 9 x 10 (exp -15) with 10 second averaging time. Ranging and range-rate as a function of Bit Error Rate of the communication link is reported. They are not sensitive to the link error rate. In the single-frequency amplitude modulation mode, we report a two-way range rate error of 0.8 microns/s, or a modified Allan deviation of 2.6 x 10 (exp -15) with 10 second averaging time. We identified the major noise sources in the current system as the transmitter modulation injected noise and receiver electronics generated noise. A new improved system will be constructed to further improve the system performance for both operating modes.

  10. The application of MultiView Methods for High Precision Astrometric Space VLBI at Low Frequencies

    CERN Document Server

    Dodson, R; Asaki, Y; Imai, H; Hong, X -Y; Shen, Z

    2013-01-01

    High precision astrometric Space Very Long Baseline Interferometry (S-VLBI) at the low end of the conventional frequency range, i.e. 20cm, is a requirement for a number of high priority science goals. These are headlined by obtaining trigonometric parallax distances to pulsars in Pulsar--Black Hole pairs and OH masers anywhere in the Milky Way Galaxy and the Magellanic Clouds. We propose a solution for the most difficult technical problems in S-VLBI by the MultiView approach where multiple sources, separated by several degrees on the sky, are observed simultaneously. We simulated a number of challenging S-VLBI configurations, with orbit errors up to 8m in size and with ionospheric atmospheres consistant with poor conditions. In these simulations we performed MultiView analysis to achieve the required science goals. This approach removes the need for beam switching requiring a Control Moment Gyro, and the space and ground infrastructure required for high quality orbit reconstruction of a space-based radio tele...

  11. Genetic association studies in lumbar disc degeneration: a systematic review.

    Directory of Open Access Journals (Sweden)

    Pasi J Eskola

    Full Text Available OBJECTIVE: Low back pain is associated with lumbar disc degeneration, which is mainly due to genetic predisposition. The objective of this study was to perform a systematic review to evaluate genetic association studies in lumbar disc degeneration as defined on magnetic resonance imaging (MRI in humans. METHODS: A systematic literature search was conducted in MEDLINE, MEDLINE In-Process, SCOPUS, ISI Web of Science, The Genetic Association Database and The Human Genome Epidemiology Network for information published between 1990-2011 addressing genes and lumbar disc degeneration. Two investigators independently identified studies to determine inclusion, after which they performed data extraction and analysis. The level of cumulative genetic association evidence was analyzed according to The HuGENet Working Group guidelines. RESULTS: Fifty-two studies were included for review. Forty-eight studies reported at least one positive association between a genetic marker and lumbar disc degeneration. The phenotype definition of lumbar disc degeneration was highly variable between the studies and replications were inconsistent. Most of the associations presented with a weak level of evidence. The level of evidence was moderate for ASPN (D-repeat, COL11A1 (rs1676486, GDF5 (rs143383, SKT (rs16924573, THBS2 (rs9406328 and MMP9 (rs17576. CONCLUSIONS: Based on this first extensive systematic review on the topic, the credibility of reported genetic associations is mostly weak. Clear definition of lumbar disc degeneration phenotypes and large population-based cohorts are needed. An international consortium is needed to standardize genetic association studies in relation to disc degeneration.

  12. High-precision astrometry on the VLT/FORS1 at time scales of few days

    CERN Document Server

    Lazorenko, P F; Dominik, M; Pepe, F; Ségransan, D; Udry, S

    2007-01-01

    We investigate the accuracy of astrometric measurements with the VLT/FORS1 camera and consider potential applications. The study is based on two-epoch (2000 and 2002/2003) frame series of observations of a selected Galactic Bulge sky region that were obtained with FORS1 during four consecutive nights each. Reductions were carried out with a novel technique that eliminates atmospheric image motion and does not require a distinction between targets and reference objects. The positional astrometric precision was found to be limited only by the accuracy of the determination of the star photocentre, which is typically 200-300 microarcsec per single measurement for bright unsaturated stars B=18-19. Several statistical tests have shown that at time-scales of 1-4 nights the residual noise in measured positions is essentially a white noise with no systematic instrumental signature and no significant deviation from a Gaussian distribution. Some evidence of a good astrometric quality of the VLT for frames separated by t...

  13. High Precision Magnetic Field Scanning System for the New Muon g-2 Experiment

    Science.gov (United States)

    Hong, Ran; Muon g-2 collaboration Collaboration

    2017-01-01

    The New Muon g-2 Experiment (E989) at Fermilab will measure the anomalous magnetic moment of muon aμ aiming at a precision of 140 ppb. This new experiment will shed light on the long-standing 3.5 standard deviation between the previous muon g-2 measurement (E821) at Brookhaven National Laboratory and the Standard Model calculation, and potentially discover new physics. The New Muon g-2 Experiment measures the precession frequency of muon in a uniform magnetic field, and the magnetic field experienced by the muons needs to be measured with a precision better than 70 ppb. For the measurement of the magnetic field in the muon storage region, the former trolley system from E821 with 17 NMR probes was refurbished and upgraded with new electronics, probes and a modern motion control system. A test solenoid magnet was set up at Argonne National Laboratory for calibrating the NMR probes and the precision studies of systematic uncertainties. In this presentation, we will describe the trolley motion control scheme, the trolley position measurement methods, the electronic system for activating and reading the NMR probes and the test solenoid facility.

  14. A highly precise and portable genome engineering method allows comparison of mutational effects across bacterial species.

    Science.gov (United States)

    Nyerges, Ákos; Csörgő, Bálint; Nagy, István; Bálint, Balázs; Bihari, Péter; Lázár, Viktória; Apjok, Gábor; Umenhoffer, Kinga; Bogos, Balázs; Pósfai, György; Pál, Csaba

    2016-03-01

    Currently available tools for multiplex bacterial genome engineering are optimized for a few laboratory model strains, demand extensive prior modification of the host strain, and lead to the accumulation of numerous off-target modifications. Building on prior development of multiplex automated genome engineering (MAGE), our work addresses these problems in a single framework. Using a dominant-negative mutant protein of the methyl-directed mismatch repair (MMR) system, we achieved a transient suppression of DNA repair in Escherichia coli, which is necessary for efficient oligonucleotide integration. By integrating all necessary components into a broad-host vector, we developed a new workflow we term pORTMAGE. It allows efficient modification of multiple loci, without any observable off-target mutagenesis and prior modification of the host genome. Because of the conserved nature of the bacterial MMR system, pORTMAGE simultaneously allows genome editing and mutant library generation in other biotechnologically and clinically relevant bacterial species. Finally, we applied pORTMAGE to study a set of antibiotic resistance-conferring mutations in Salmonella enterica and E. coli. Despite over 100 million y of divergence between the two species, mutational effects remained generally conserved. In sum, a single transformation of a pORTMAGE plasmid allows bacterial species of interest to become an efficient host for genome engineering. These advances pave the way toward biotechnological and therapeutic applications. Finally, pORTMAGE allows systematic comparison of mutational effects and epistasis across a wide range of bacterial species.

  15. Drone-acquired structure-from-motion photogrammetry for high-precision measurements of biomass in semi-arid rangelands

    Science.gov (United States)

    Cunliffe, Andrew; Brazier, Richard; Anderson, Karen

    2016-04-01

    Covering 40% of the terrestrial surface, dryland ecosystems have a distinct vegetation structure that is strongly linked to their function. Recent global modelling studies have indicated interannual variations in semiarid ecosystem biomass accounts for ca. 40%-60% of interannual variations in atmospheric carbon dioxide concentrations. Empirical evidence is needed to validate these model predictions; however, existing survey approaches cannot provide sufficiently precise data at landscape-scale extents to quantify this structure appropriately. Using a small unpiloted aerial system (UAS) to acquire aerial photographs and processing using structure-from-motion (SfM) photogrammetry, three dimensional models were produced quantifying the vegetation structure of semi-arid ecosystems at seven areas of interest (AOI). This approach yielded ultrafine (0.64) supported prediction of aboveground biomass from canopy volume. Canopy volumes, modelled biomass and carbon stocks were sensitive to spatial changes in vegetation community structure. We demonstrate the use of an inexpensive UAS and SfM photogrammetry to produce ultrafine-scale biophysical data products. The high-precision of this approach affords sensitivity to subtle differences in the biotic structure (and therefore function) of heterogeneous ecosystems subject to rapid environmental change, and has exciting potential to revolutionise the study of spatial ecology in ecosystems with either spatially or temporally discontinuous canopy cover.

  16. High-Precision Multi-Wave Rectifier Circuit Operating in Low Voltage + 1.5 Volt Current Mode

    Directory of Open Access Journals (Sweden)

    Bancha Burapattanasiri

    2009-12-01

    Full Text Available This article is present high-precision multi-wave rectifier circuit operating in low voltage +/- 1.5 Volt current modes by CMOS technology 0.5 μm, receive input and give output in current mode, respond at high frequency period. The structure compound with high-speed current comparator circuit, current mirror circuit, and CMOS inverter circuit. PSpice program used for confirmation the performance of testing. The PSpice program shows operating of circuit is able to working at maximum input current 400 μAp-p, maximum frequency responding 200 MHz, high precision and low power losses, and non-precision zero crossing output signal.Keywords-component; rectifier circuit; high-precision; low voltage; current mode;

  17. A novel approach for pulse width measurements with a high precision (8 ps RMS) TDC in an FPGA

    Science.gov (United States)

    Ugur, C.; Linev, S.; Michel, J.; Schweitzer, T.; Traxler, M.

    2016-01-01

    High precision time measurements are a crucial element in particle identification experiments, which likewise require pulse width information for Time-over-Threshold (ToT) measurements and charge measurements (correlated with pulse width). In almost all of the FPGA-based TDC applications, pulse width measurements are implemented using two of the TDC channels for leading and trailing edge time measurements individually. This method however, requires twice the number of resources. In this paper we present the latest precision improvements in the high precision TDC (8 ps RMS) developed before [1], as well as the novel way of measuring ToT using a single TDC channel, while still achieving high precision (as low as 11.7 ps RMS). The effect of voltage, generated by a DC-DC converter, over the precision is also discussed. Finally, the outcome of the temperature change over the pulse width measurement is shown and a correction method is suggested to limit the degradation.

  18. High-precision mapping of seismicity in the 2014 Bárdarbunga volcanic episode

    Science.gov (United States)

    Vogfjörd, Kristín S.; Hensch, Martin; Gudmundsson, Gunnar B.; Jónsdóttir, Kristín

    2015-04-01

    The Bárdarbunga volcano and its associated fissure swarm in Iceland's Eastern volcanic zone is a highly active system with over 20 eruptions in the last 11 centuries. The location of this active volcano and much of the fissure swarm under several hundred metres thick ice gives rise to multiple hazards, including explosive, subglacial eruptions and associated subglacial floods (jökulhlaups), as well as fissure eruptions extruding large volumes of lava. After a decade of increasing seismic activity, volcanic unrest at Bárdarbunga suddenly escalated into a minor subglacial eruption on 16 August 2014. In the following weeks seismic activity soared and surface deformation of tens of cm were observed, caused by rifting and a dyke intrusion, which propagated 48 km northward from the central volcano (Sigmundsson et al., 2014). The dyke propagation stopped just outside the glacial margin and ended in a fissure eruption at Holuhraun at the end of August. At the time of writing the eruption is ongoing, having extruded a lava volume of over 1 km3 and released high rates of SO2 into the atmosphere. Over twenty thousand microearthquakes have been recorded. Initially most were in the dyke, but after the first two weeks the activity around the caldera rim increased and over 70 shallow earthquakes with MW > 5 have been located along the caldera rim accompanied by caldera subsidence. At the onset of the unrest on 16 August, the seismicity was located in the caldera and north of the caldera rim, but already in the first few hours the activity propagated out of the caldera to the SE. Still, the activity continued for a few days in the fissure swarm to the NE of the rim. High-precision earthquake locations in the propagating dyke have revealed its very detailed, planar rifting segments, with the events distributed over a 3-4 km depth range, and mostly between 6 and 9 km. These very planar event distributions are highly unusual in volcanic areas and strongly suggest rifting of

  19. High-precision predictions for the light CP-even Higgs boson mass of the minimal supersymmetric standard model.

    Science.gov (United States)

    Hahn, T; Heinemeyer, S; Hollik, W; Rzehak, H; Weiglein, G

    2014-04-11

    For the interpretation of the signal discovered in the Higgs searches at the LHC it will be crucial in particular to discriminate between the minimal Higgs sector realized in the standard model (SM) and its most commonly studied extension, the minimal supersymmetric standard model (MSSM). The measured mass value, having already reached the level of a precision observable with an experimental accuracy of about 500 MeV, plays an important role in this context. In the MSSM the mass of the light CP-even Higgs boson, Mh, can directly be predicted from the other parameters of the model. The accuracy of this prediction should at least match the one of the experimental result. The relatively high mass value of about 126 GeV has led to many investigations where the scalar top quarks are in the multi-TeV range. We improve the prediction for Mh in the MSSM by combining the existing fixed-order result, comprising the full one-loop and leading and subleading two-loop corrections, with a resummation of the leading and subleading logarithmic contributions from the scalar top sector to all orders. In this way for the first time a high-precision prediction for the mass of the light CP-even Higgs boson in the MSSM is possible all the way up to the multi-TeV region of the relevant supersymmetric particles. The results are included in the code FEYNHIGGS.

  20. High-precision radiocarbon dating of political collapse and dynastic origins at the Maya site of Ceibal, Guatemala.

    Science.gov (United States)

    Inomata, Takeshi; Triadan, Daniela; MacLellan, Jessica; Burham, Melissa; Aoyama, Kazuo; Palomo, Juan Manuel; Yonenobu, Hitoshi; Pinzón, Flory; Nasu, Hiroo

    2017-02-07

    The lowland Maya site of Ceibal, Guatemala, had a long history of occupation, spanning from the Middle Preclassic Period through the Terminal Classic (1000 BC to AD 950). The Ceibal-Petexbatun Archaeological Project has been conducting archaeological investigations at this site since 2005 and has obtained 154 radiocarbon dates, which represent the largest collection of radiocarbon assays from a single Maya site. The Bayesian analysis of these dates, combined with a detailed study of ceramics, allowed us to develop a high-precision chronology for Ceibal. Through this chronology, we traced the trajectories of the Preclassic collapse around AD 150-300 and the Classic collapse around AD 800-950, revealing similar patterns in the two cases. Social instability started with the intensification of warfare around 75 BC and AD 735, respectively, followed by the fall of multiple centers across the Maya lowlands around AD 150 and 810. The population of Ceibal persisted for some time in both cases, but the center eventually experienced major decline around AD 300 and 900. Despite these similarities in their diachronic trajectories, the outcomes of these collapses were different, with the former associated with the development of dynasties centered on divine rulership and the latter leading to their downfalls. The Ceibal dynasty emerged during the period of low population after the Preclassic collapse, suggesting that this dynasty was placed under the influence from, or by the direct intervention of, an external power.

  1. High-precision QEC values of superallowed 0+ → 0+β-emitters 46Cr, 50Fe and 54Ni

    Science.gov (United States)

    Zhang, P.; Xu, X.; Shuai, P.; Chen, R. J.; Yan, X. L.; Zhang, Y. H.; Wang, M.; Litvinov, Yu. A.; Blaum, K.; Xu, H. S.; Bao, T.; Chen, X. C.; Chen, H.; Fu, C. Y.; He, J. J.; Kubono, S.; Lam, Y. H.; Liu, D. W.; Mao, R. S.; Ma, X. W.; Sun, M. Z.; Tu, X. L.; Xing, Y. M.; Yang, J. C.; Yuan, Y. J.; Zeng, Q.; Zhou, X.; Zhou, X. H.; Zhan, W. L.; Litvinov, S.; Audi, G.; Uesaka, T.; Yamaguchi, Y.; Yamaguchi, T.; Ozawa, A.; Sun, B. H.; Sun, Y.; Xu, F. R.

    2017-04-01

    Short-lived 46Cr, 50Fe and 54Ni were studied by isochronous mass spectrometry at the HIRFL-CSR facility in Lanzhou. The measured precision mass excesses (ME) of 46Cr, 50Fe and 54Ni are - 29471 (11) keV, - 34477 (6) keV and - 39278 (4) keV, respectively. The superallowed 0+ →0+β-decay Q values were derived to be QEC (46Cr) = 7604 (11) keV, QEC (50Fe) = 8150 (6) keV and QEC (54Ni) = 8731 (4) keV. The values for 50Fe and 54Ni are by one order of magnitude more precise than the adopted literature values. By combining the existing half-lives and branching ratios, we obtained the corrected Ft values to be Ft (50Fe) = 3103 (70) s and Ft (54Ni) = 3076 (50) s. The main contribution to the Ft uncertainties is now due to β-decay branching ratios, still, more high-precision measurements of the half-lives, the masses, and especially the branching ratios are needed in order to satisfy the requirements for a stringent CVC test.

  2. Landslide monitoring with combined methodology: geoelectrical anisotropy, PSInSAR and high precision leveling in Dunaszekcso, Hungary

    Science.gov (United States)

    Fusi, B.; Madarasi, A.

    2012-12-01

    The surface deformations in Hungary regarded as a priority source of geological hazards. The identification of the vulnerable parts of the affected areas, the impoundment and registration of the endangered territory and understanding of the mechanisms and triggering conditions are public tasks. In this case study we would like to present our two years achievements in the DORIS project (under grant agreement n° [242212]) within the European Union Seventh Framework Programme (FP7/2007-2013) in Dunaszekcso test area. After the regulation of the Danube, there are only few areas where high loess river banks can be found near the river bed, but there the ground deformation is continuous in this regions. The most affected area is Dunaszekcso, where several landslide events happened in the past, the last one in 2010 February. A new crack started to open in 2011 April. We monitored both the development of the crack with geoelectrical anisotropy measurements and the motion of the whole area with PSInSAR analysis (ALTAMIRA) and high precision leveling (GGKI). Since the area is densely populated, the main goal of these measurements is to predict the propagation of the subsurface crack in the loess river bank to provide information about the endangered areas before the next collapse. In my presentation I would like to introduce the test area, the applied methods and the achieved results.

  3. Compact Integration of a GSM-19 Magnetic Sensor with High-Precision Positioning using VRS GNSS Technology

    Directory of Open Access Journals (Sweden)

    Santiago Belda

    2009-04-01

    Full Text Available Magnetic data consists of a sequence of collected points with spatial coordinates and magnetic information. The spatial location of these points needs to be as exact as possible in order to develop a precise interpretation of magnetic anomalies. GPS is a valuable tool for accomplishing this objective, especially if the RTK approach is used. In this paper the VRS (Virtual Reference Station technique is introduced as a new approach for real-time positioning of magnetic sensors. The main advantages of the VRS approach are, firstly, that only a single GPS receiver is needed (no base station is necessary, reducing field work and equipment costs. Secondly, VRS can operate at distances separated 50-70 km from the reference stations without degrading accuracy. A compact integration of a GSM-19 magnetometer sensor with a geodetic GPS antenna is presented; this integration does not diminish the operational flexibility of the original magnetometer and can work with the VRS approach. The coupled devices were tested in marshlands around Gandia, a city located approximately 100 km South of Valencia (Spain, thought to be the site of a Roman cemetery. The results obtained show adequate geometry and high-precision positioning for the structures to be studied (a comparison with the original low precision GPS of the magnetometer is presented. Finally, the results of the magnetic survey are of great interest for archaeological purposes.

  4. Compact Integration of a GSM-19 Magnetic Sensor with High-Precision Positioning using VRS GNSS Technology.

    Science.gov (United States)

    Martín, Angel; Padín, Jorge; Anquela, Ana Belén; Sánchez, Juán; Belda, Santiago

    2009-01-01

    Magnetic data consists of a sequence of collected points with spatial coordinates and magnetic information. The spatial location of these points needs to be as exact as possible in order to develop a precise interpretation of magnetic anomalies. GPS is a valuable tool for accomplishing this objective, especially if the RTK approach is used. In this paper the VRS (Virtual Reference Station) technique is introduced as a new approach for real-time positioning of magnetic sensors. The main advantages of the VRS approach are, firstly, that only a single GPS receiver is needed (no base station is necessary), reducing field work and equipment costs. Secondly, VRS can operate at distances separated 50-70 km from the reference stations without degrading accuracy. A compact integration of a GSM-19 magnetometer sensor with a geodetic GPS antenna is presented; this integration does not diminish the operational flexibility of the original magnetometer and can work with the VRS approach. The coupled devices were tested in marshlands around Gandia, a city located approximately 100 km South of Valencia (Spain), thought to be the site of a Roman cemetery. The results obtained show adequate geometry and high-precision positioning for the structures to be studied (a comparison with the original low precision GPS of the magnetometer is presented). Finally, the results of the magnetic survey are of great interest for archaeological purposes.

  5. A robust and high precision optimal explicit guidance scheme for solid motor propelled launch vehicles with thrust and drag uncertainty

    Science.gov (United States)

    Maity, Arnab; Padhi, Radhakant; Mallaram, Sanjeev; Mallikarjuna Rao, G.; Manickavasagam, M.

    2016-10-01

    A new nonlinear optimal and explicit guidance law is presented in this paper for launch vehicles propelled by solid motors. It can ensure very high terminal precision despite not having the exact knowledge of the thrust-time curve apriori. This was motivated from using it for a carrier launch vehicle in a hypersonic mission, which demands an extremely narrow terminal accuracy window for the launch vehicle for successful initiation of operation of the hypersonic vehicle. The proposed explicit guidance scheme, which computes the optimal guidance command online, ensures the required stringent final conditions with high precision at the injection point. A key feature of the proposed guidance law is an innovative extension of the recently developed model predictive static programming guidance with flexible final time. A penalty function approach is also followed to meet the input and output inequality constraints throughout the vehicle trajectory. In this paper, the guidance law has been successfully validated from nonlinear six degree-of-freedom simulation studies by designing an inner-loop autopilot as well, which enhances confidence of its usefulness significantly. In addition to excellent nominal results, the proposed guidance has been found to have good robustness for perturbed cases as well.

  6. High-precision QEC values of superallowed 0+→0+ β-emitters 46Cr, 50Fe and 54Ni

    Directory of Open Access Journals (Sweden)

    P. Zhang

    2017-04-01

    Full Text Available Short-lived 46Cr, 50Fe and 54Ni were studied by isochronous mass spectrometry at the HIRFL-CSR facility in Lanzhou. The measured precision mass excesses (ME of 46Cr, 50Fe and 54Ni are −29471(11 keV, −34477(6 keV and −39278(4 keV, respectively. The superallowed 0+→0+ β-decay Q values were derived to be QEC(Cr46=7604(11 keV, QEC(Fe50=8150(6 keV and QEC(Ni54=8731(4 keV. The values for 50Fe and 54Ni are by one order of magnitude more precise than the adopted literature values. By combining the existing half-lives and branching ratios, we obtained the corrected Ft values to be Ft(Fe50=3103(70 s and Ft(Ni54=3076(50 s. The main contribution to the Ft uncertainties is now due to β-decay branching ratios, still, more high-precision measurements of the half-lives, the masses, and especially the branching ratios are needed in order to satisfy the requirements for a stringent CVC test.

  7. Development of a High Precision and Stability Ambient N2O and CO Analyzer

    Science.gov (United States)

    Zhou, Jingang; Hoffnagle, John; Tan, Sze; Dong, Feng; Fleck, Derek; Yiu, John; Huang, Kuan; Leggett, Graham; He, Yonggang

    2016-04-01

    With a global warming potential of nearly 300, N2O is a critically important greenhouse gas, contributing about 5 % of the US total GHG emissions. Agriculture soil management practices are the dominant source of anthropogenic N2O emissions, contributing nearly 75 % of US N2O emissions. In urban areas, vehicle tailpipe emissions and waste water treatment plants are significant sources of N2O. We report here a new mid-infrared laser-based cavity ring-down spectrometer (Picarro G5310) that was recently developed to simultaneously measure sub-ppb ambient concentrations of two key greenhouse gas species, N2O and CO, while measuring H2O as well. It combines a quantum cascade laser with a proprietary 3-mirror optical cavity. The ambient N2O and CO measurement precisions are 0.1ppb (10sec), 0.014ppb (600sec), and 0.006ppb (3000sec); and the measurements could even be averaged down over 3 hours, giving measurement precisions of 0.003ppb. The measurable N2O and CO ranges have been tested up to 2.5ppm. With the high precision and unparalleled stability, G5310 is believed a promising tool for long-term monitoring in atmospheric sciences. The new optical analyzer was set up to monitor N2O and CO (G5310), along with CO2 and CH4(G4301), in ambient air obtained from a 10 meter tower in Santa Clara, California. Evidence of contributions from traffic and a nearby sewage treatment facility were expected in the measurement data.

  8. The NANOGrav Eleven-Year Data Set: High-precision timing of 48 Millisecond Pulsars

    Science.gov (United States)

    Nice, David J.; NANOGrav

    2017-01-01

    Gravitational waves from sources such as supermassive black hole binary systems perturb times-of-flight of signals traveling from pulsars to the Earth. The NANOGrav collaboration aims to measure these perturbations in high precision millisecond pulsar timing data and thus to directly detect gravitational waves and characterize the gravitational wave sources. By observing pulsars over time spans of many years, we are most sensitive to gravitational waves at nanohertz frequencies. This work is complimentary to ground based detectors such as LIGO, which are sensitive to gravitational waves with frequencies 10 orders of magnitude higher.In this presentation we describe the NANOGrav eleven-year data set. This includes pulsar time-of-arrival measurements from 48 millisecond pulsars made with the Arecibo Observatory (for pulsars with declinations between -1 and 39 degrees) and the Green Bank Telescope (for other pulsars, with two pulsars overlapping with Arecibo). The data set consists of more than 300,000 pulse time-of-arrival measurements made in nearly 7000 unique observations (a given pulsar observed with a given telescope receiver on a given day). In the best cases, measurement precision is better than 100 nanoseconds, and in nearly all cases it is better than 1 microsecond.All pulsars in our program are observed at intervals of 3 to 4 weeks. Observations use wideband data acquisition systems and are made at two receivers at widely separated frequencies at each epoch, allowing for characterization and mitigation of the effects of interstellar medium on the signal propagation. Observation of a large number of pulsars allows for searches for correlated perturbations among the pulsar signals, which is crucial for achieving high-significance detection of gravitational waves in the face of uncorrelated noise (from gravitational waves and rotation noise) in the individual pulsars. In addition, seven pulsars are observed at weekly intervals. This increases our sensitivity

  9. Three years of high precision gravity measurements at the gravimetric station of Brasimone - Italy

    Directory of Open Access Journals (Sweden)

    G. Casula

    1998-06-01

    Full Text Available From August 1995 up to now, at the Enea Research Center of Brasimone, in the Italian Apennines between Bologna and Florence (Italy: 44º07'N, 11º.07'E, 890 m height, the superconducting gravimeter GWR model TT70 number T015 has been continuously recording the variation of the local gravity field, in the frame of the Global Geodynamics Project. The gravimetric laboratory, being a room of the disused nuclear power plant of Brasimone, is a very stable site, free from noise due to human activities. Data blocks of several months of continuous gravity records have been collected over a time span of three years, together with the meteorological data. The gravimeter has been calibrated at relative accuracy better than 0.3% with the aid of a mobile mass system, by imposed perturbations of the local gravity field and recording the gravimeter response. The results of this calibration technique were checked by two comparison experiments with absolute gravimeters performed during this period: the first, in May 1994 with the aid of the symmetrical rise and fall gravimeter of the Institute of Metrology Colonnetti of Turin, and the second in October 1997 involving an FG5 absolute gravimeter of the Institute de Physique du Globe of Strasbourg. The gravimeter signal was analysed to compute a high precision tidal model for Brasimone site. Starting from a set of gravimetric and atmospheric pressure data of high quality, relative to 46 months of observation, we performed the tidal analysis using Eterna 3.2 software to compute amplitudes, gravimetric factors and phases of the main waves of the Tamura catalogue. Finally a comparison experiment between two of the STS-1/VBB broadband seismometers of the MedNet project network and the gravity records relative to the Balleny Islands earthquake (March 25, 1998 were analysed to look for evidence of normal modes due to the free oscillations of the Earth.

  10. High-Precision Ephemerides of Planets—EPM and Determination of Some Astronomical Constants

    Science.gov (United States)

    Pitjeva, E. V.

    2005-05-01

    The latest version of the planetary part of the numerical ephemerides EPM (Ephemerides of Planets and the Moon) developed at the Institute of Applied Astronomy of the Russian Academy of Sciences is presented. The ephemerides of planets and the Moon were constructed by numerical integration in the post-Newtonian metric over a 140-year interval (from 1880 to 2020). The dynamical model of EPM2004 ephemerides includes the mutual perturbations from major planets and the Moon computed in terms of General Relativity with allowance for effects due to lunar physical libration, perturbations from 301 big asteroids, and dynamic perturbations due to the solar oblateness and the massive asteroid ring with uniform mass distribution in the plane of the ecliptic. The EPM2004 ephemerides resulted from a least-squares adjustment to more than 317000 position observations (1913 2003) of various types, including radiometric measurements of planets and spacecraft, CCD astrometric observations of the outer planets and their satellites, and meridian and photographic observations. The high-precision ephemerides constructed made it possible to determine, from modern radiometric measurements, a wide range of astrometric constants, including the astronomical unit AU = (149597870.6960 ± 0.0001) km, parameters of the rotation of Mars, the masses of the biggest asteroids, the solar quadrupole moment J 2 = (1.9 ± 0.3) × 10-7, and the parameters of the PPN formalism β and γ. Also given is a brief summary of the available state-of-the-art ephemerides with the same precision: various versions of EPM and DE ephemerides from the Jet Propulsion Laboratory (JPL) (USA) and the recent versions of these ephemerides—EPM2004 and DE410—are compared. EPM2004 ephemerides are available via FTP at ftp://qua-sar.ipa.nw.ru/incoming/EPM2004.

  11. A high precision method for quantitative measurements of reactive oxygen species in frozen biopsies.

    Directory of Open Access Journals (Sweden)

    Kirsti Berg

    Full Text Available OBJECTIVE: An electron paramagnetic resonance (EPR technique using the spin probe cyclic hydroxylamine 1-hydroxy-3-methoxycarbonyl-2,2,5,5-tetramethylpyrrolidine (CMH was introduced as a versatile method for high precision quantification of reactive oxygen species, including the superoxide radical in frozen biological samples such as cell suspensions, blood or biopsies. MATERIALS AND METHODS: Loss of measurement precision and accuracy due to variations in sample size and shape were minimized by assembling the sample in a well-defined volume. Measurement was carried out at low temperature (150 K using a nitrogen flow Dewar. The signal intensity was measured from the EPR 1st derivative amplitude, and related to a sample, 3-carboxy-proxyl (CP• with known spin concentration. RESULTS: The absolute spin concentration could be quantified with a precision and accuracy better than ±10 µM (k = 1. The spin concentration of samples stored at -80°C could be reproduced after 6 months of storage well within the same error estimate. CONCLUSION: The absolute spin concentration in wet biological samples such as biopsies, water solutions and cell cultures could be quantified with higher precision and accuracy than normally achievable using common techniques such as flat cells, tissue cells and various capillary tubes. In addition; biological samples could be collected and stored for future incubation with spin probe, and also further stored up to at least six months before EPR analysis, without loss of signal intensity. This opens for the possibility to store and transport incubated biological samples with known accuracy of the spin concentration over time.

  12. Project GeoWSN: High precision but low-cost GNSS landslide monitoring in Austria

    Science.gov (United States)

    Koch, Daniel; Brandstätter, Michael; Kühtreiber, Norbert

    2014-05-01

    At present, GNSS monitoring of landslides is an accepted and approved method to detect movements of slopes at risk in the sub-centimetre level. However, high-precision geodetic GNSS-receivers are expensive, therefore this monitoring method is not widely applied. Recently low-cost GNSS-receivers are conquering the geodetic market and are well suited for a cost effective and yet precise GNSS-monitoring. During the project GeoWSN, which was funded by the Austrian Research Promotion Agency (FFG), an applicable low-cost monitoring system was developed at Graz University of Technology. The system is based on a so-called Wireless Sensor Network (WSN) consisting of low-cost GNSS-receivers, temperature and humidity sensors and inertial measurement units. Additionally energy-harvesting technologies and power-saving algorithms provide that the system is energy- autarkic. For real-time applications, a communication link between the sensor nodes is implemented. The relative positioning method RTK (Real Time Kinematic) is applied to reach the highest possible accuracy. The GeoWSN sensor nodes enable the detection of possible movements in the real-time processed positions of the sensor nodes. To ensure a real-time evaluation and interpretation of the data, the current status of the slope can be acquired by a local warning centre. Therefore, affected people can be warned within a short latency. Several test-scenarios have shown the acceptance of the system at the warning centre of Styria, Austria. This contribution should give an overview of the main idea of a low-cost warning system and results of the project GeoWSN.

  13. Highly precise and developmentally programmed genome assembly in Paramecium requires ligase IV-dependent end joining.

    Directory of Open Access Journals (Sweden)

    Aurélie Kapusta

    2011-04-01

    Full Text Available During the sexual cycle of the ciliate Paramecium, assembly of the somatic genome includes the precise excision of tens of thousands of short, non-coding germline sequences (Internal Eliminated Sequences or IESs, each one flanked by two TA dinucleotides. It has been reported previously that these genome rearrangements are initiated by the introduction of developmentally programmed DNA double-strand breaks (DSBs, which depend on the domesticated transposase PiggyMac. These DSBs all exhibit a characteristic geometry, with 4-base 5' overhangs centered on the conserved TA, and may readily align and undergo ligation with minimal processing. However, the molecular steps and actors involved in the final and precise assembly of somatic genes have remained unknown. We demonstrate here that Ligase IV and Xrcc4p, core components of the non-homologous end-joining pathway (NHEJ, are required both for the repair of IES excision sites and for the circularization of excised IESs. The transcription of LIG4 and XRCC4 is induced early during the sexual cycle and a Lig4p-GFP fusion protein accumulates in the developing somatic nucleus by the time IES excision takes place. RNAi-mediated silencing of either gene results in the persistence of free broken DNA ends, apparently protected against extensive resection. At the nucleotide level, controlled removal of the 5'-terminal nucleotide occurs normally in LIG4-silenced cells, while nucleotide addition to the 3' ends of the breaks is blocked, together with the final joining step, indicative of a coupling between NHEJ polymerase and ligase activities. Taken together, our data indicate that IES excision is a "cut-and-close" mechanism, which involves the introduction of initiating double-strand cleavages at both ends of each IES, followed by DSB repair via highly precise end joining. This work broadens our current view on how the cellular NHEJ pathway has cooperated with domesticated transposases for the emergence of new

  14. Injection molding of high precision optics for LED applications made of liquid silicone rubber

    Energy Technology Data Exchange (ETDEWEB)

    Hopmann, Christian; Röbig, Malte [Institute of Plastics Processing (IKV), RWTH Aachen University, Pontstraße 49, 52062 Aachen (Germany)

    2016-03-09

    Light Emitting Diodes (LED) conquer the growing global market of lighting technologies. Due to their advantages, they are increasingly used in consumer products, in lighting applications in the home and in the mobility sector as well as in industrial applications. Particularly, with regard to the increasing use of high-power LED (HP-LED) the materials in the surrounding area of the light emitting semiconductor chip are of utmost importance. While the materials behind the semiconductor chip are optimized for maximum heat dissipation, the materials currently used for the encapsulation of the semiconductor chip (primary optics) and the secondary optics encounter their limits due to the high temperatures. In addition certain amounts of blue UV radiation degrade the currently used materials such as epoxy resins or polyurethanes for primary optics. In the context of an ongoing joint research project with various partners from the industry, an innovative manufacturing method for high precision optics for LED applications made of liquid silicone rubber (LSR) is analyzed at the Institut of Plastics Processing (IKV), Aachen. The aim of this project is to utilize the material-specific advantages of high transparent LSR, especially the excellent high temperature resistance and the great freedom in design. Therefore, a high integrated injection molding process is developed. For the production of combined LED primary and secondary optics a LED board is placed in an injection mold and overmolded with LSR. Due to the integrated process and the reduction of subcomponents like the secondary optics the economics of the production process can be improved significantly. Furthermore combined LED optics offer an improved effectiveness, because there are no losses of the light power at the transition of the primary and secondary optics.

  15. A low noise and high precision linear power supply with thermal foldback protection

    Science.gov (United States)

    Carniti, P.; Cassina, L.; Gotti, C.; Maino, M.; Pessina, G.

    2016-05-01

    A low noise and high precision linear power supply was designed for use in rare event search experiments with macrobolometers. The circuit accepts at the input a "noisy" dual supply voltage up to ±15 V and gives at the output precise, low noise, and stable voltages that can be set between ±3.75 V and ±12.5 V in eight 1.25 V steps. Particular care in circuit design, component selection, and proper filtering results in a noise spectral density of 50 nV / √{ Hz } at 1 Hz and 20 nV / √{ Hz } white when the output is set to ±5 V. This corresponds to 125 nV RMS (0.8 μV peak to peak) between 0.1 Hz and 10 Hz, and 240 nV RMS (1.6 μV peak to peak) between 0.1 Hz and 100 Hz. The power supply rejection ratio (PSRR) of the circuit is 100 dB at low frequency, and larger than 40 dB up to high frequency, thanks to a proper compensation design. Calibration allows to reach a precision in the absolute value of the output voltage of ±70 ppm, or ±350 μV at ±5 V, and to reduce thermal drifts below ±1 ppm/∘C in the expected operating range. The maximum peak output current is about 6 A from each output. An original foldback protection scheme was developed that dynamically limits the maximum output current to keep the temperature of the output transistors within their safe operating range. An add-on card based on an ARM Cortex-M3 microcontroller is devoted to the monitoring and control of all circuit functionalities and provides remote communication via CAN bus.

  16. HIGH-PRECISION PREDICTIONS FOR THE ACOUSTIC SCALE IN THE NONLINEAR REGIME

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hee-Jong; Eckel, Jonathan; Eisenstein, Daniel J.; Mehta, Kushal; Metchnik, Marc; Padmanabhan, Nikhil; Pinto, Phillip; Takahashi, Ryuichi; White, Martin; Xu, Xiaoying

    2010-09-10

    We measure shifts of the acoustic scale due to nonlinear growth and redshift distortions to a high precision using a very large volume of high-force-resolution simulations. We compare results from various sets of simulations that differ in their force, volume, and mass resolution. We find a consistency within 1.5-sigma for shift values from different simulations and derive shift alpha(z) -1 = (0.300\\pm 0.015)% [D(z)/D(0)]^{2} using our fiducial set. We find a strong correlation with a non-unity slope between shifts in real space and in redshift space and a weak correlation between the initial redshift and low redshift. Density-field reconstruction not only removes the mean shifts and reduces errors on the mean, but also tightens the correlations: after reconstruction, we recover a slope of near unity for the correlation between the real and redshift space and restore a strong correlation between the low and the initial redshifts. We derive propagators and mode-coupling terms from our N-body simulations and compared with Zeldovich approximation and the shifts measured from the chi^2 fitting, respectively. We interpret the propagator and the mode-coupling term of a nonlinear density field in the context of an average and a dispersion of its complex Fourier coefficients relative to those of the linear density field; from these two terms, we derive a signal-to-noise ratio of the acoustic peak measurement. We attempt to improve our reconstruction method by implementing 2LPT and iterative operations: we obtain little improvement. The Fisher matrix estimates of uncertainty in the acoustic scale is tested using 5000 (Gpc/h)^3 of cosmological PM simulations from Takahashi et al. (2009). (abridged)

  17. Test of feasibility of a novel high precision test of time reversal invariance

    Energy Technology Data Exchange (ETDEWEB)

    Samuel, Deepak

    2007-07-01

    The first results of a feasibility test of a novel high precision test of time reversal invariance are reported. The Time Reversal Invariance test at COSY (TRIC) was planned to measure the time reversal violating observable A{sub y,xz} with an accuracy of 10{sup -6} in proton-deuteron (p-d) scattering. A novel technique for measuring total cross sections is introduced and the achievable precision of this measuring technique is tested. The correlation coefficient A{sub y,y} in p-d scattering fakes a time-reversal violating effect. This work reports the feasibility test of the novel method in the measurement of A{sub y,y} in p-p scattering. The first step in the experimental design was the development of a hard real-time data acquisition system. To meet stringent latency requirements, the capabilities of Windows XP had to be augmented with a real-time subsystem. The remote control feature of the data acquisition enables users to operate it from any place via an internet connection. The data acquisition proved its reliability in several beam times without any failures. The analysis of the data showed the presence of 1/f noise which substantially limits the quality of our measurements. The origin of 1/f noise was traced and found to be the Barkhausen noise from the ferrite core of the beam current transformer (BCT). A global weighted fitting technique based on a modified Wiener-Khinchin method was developed and used to suppress the influence of 1/f noise, which increased the error bar of the results by a factor 3. This is the only deviation from our expectations. The results are presented and discussed. (orig.)

  18. The research of the high precision universal stable reconnaissance platform in near space

    Science.gov (United States)

    Yang, Hong-tao; Cao, Jian-zhong; Fan, Zhe-yuan; Chen, Wei-ning

    2011-08-01

    The appliance of military was recognized more and more ,It is important that pod can bear the weight of the availability payload achieve the observation to the earth in 20km-100km area and work in the all-weather. The stable platform can load high imaging spectrometer, the thermal infrared imager, the infrared radiometer, the millimeter waves radar, the laser weapon and so on,in order to realize reconnaissance and attacking integrative and warning the long-distant missile. The stabilization accuracy of platform is prior to 20μrad and burden heavy load to the best of one's abilities. It used high precision velocity and acceleration gyroscope to fulfill the stabilization of the platform. Light-weight design by using new composite material and optimizing design. It was adapt to the near space environment better by structure design and simulation analysis.Enhance its basic frequency and sure the rigid of the frame platform .In addition, the structure of platform apply the two-axis and four-frame and use the method of FEA to fulfill the optimum design in order to attain the object of light-weight.In consider to the precision of the platform I establish the math model and make use of the monte carlo method to appraise and analysis the error that affect the precision of the platform. After emulating by the software of the Matlab to verify the results. It is apply the method that link the platform and aerocraft by mounting the no angular displacement shock absorbers on the elevator mechanism. This kind of design insulate the angular vibration and minish the linear vibration to ensure the image quality.

  19. Emdogain in carcinogenesis: a systematic review of in vitro studies.

    Science.gov (United States)

    Laaksonen, Matti; Sorsa, Timo; Salo, Tuula

    2010-03-01

    Emdogain is a commercial product of unknown composition and is clinically used to induce periodontal regeneration. This study aims to review current knowledge of the in vitro effects of Emdogain on oral tissues and, in particular, factors related to carcinoma. A systematic approach was used to review studies from the Embase and Pubmed databases; a total of 76 studies were included. These comprised in vitro studies of the cytokines in, or regulated by, Emdogain and assays designed to study the effects of EMD on human cells in oral tissues or malignant cells. Several studies have shown that EMD regulates the proliferation, migration, adhesion, gene expression, and cytokine production of (pre-)osteoblasts, periodontal fibroblasts, and gingival fibroblasts. However, the effects of EMD on malignant oral cells are not well understood. EMD seems to have broad regulatory effects on malignant cells and on several carcinoma-related factors. Evidence suggests that patients with premalignant or malignant mucosal lesions should not be treated with EMD.

  20. Development of a mobile and high-precision atmospheric CO2 monitoring station

    Science.gov (United States)

    Molnár, M.; Haszpra, L.; Major, I.; Svingor, É.; Veres, M.

    2009-04-01

    Nowadays one of the most burning questions for the science is the rate and the reasons of the recent climate change. Greenhouse gases (GHG), mainly CO2 and CH4 in the atmosphere could affect the climate of our planet. However, the relation between the amount of atmospheric GHG and the climate is complex, full with interactions and feedbacks partly poorly known even by now. The only way to understand the processes, to trace the changes, to develop and validate mathematical models for forecasts is the extensive, high precision, continuous monitoring of the atmosphere. Fossil fuel CO2 emissions are a major component of the European carbon budget. Separation of the fossil fuel signal from the natural biogenic one in the atmosphere is, therefore, a crucial task for quantifying exchange flux of the continental biosphere through atmospheric observations and inverse modelling. An independent method to estimate trace gas emissions is the top-down approach, using atmospheric CO2 concentration measurements combined with simultaneous radiocarbon (14C) observations. As adding fossil fuel CO2 to the atmosphere, therefore, leads not only to an increase in the CO2 content of the atmosphere but also to a decrease in the 14C/12C ratio in atmospheric CO2. The ATOMKI has more than two decade long experience in atmospheric 14CO2 monitoring. As a part of an ongoing research project being carried out in Hungary to investigate the amount and temporal and spatial variations of fossil fuel CO2 in the near surface atmosphere we developed a mobile and high-precision atmospheric CO2 monitoring station. We describe the layout and the operation of the measuring system which is designed for the continuous, unattended monitoring of CO2 mixing ratio in the near surface atmosphere based on an Ultramat 6F (Siemens) infrared gas analyser. In the station one atmospheric 14CO2 sampling unit is also installed which is developed and widely used since more than one decade by ATOMKI. Mixing ratio of CO2 is

  1. High-precision analog circuit technology for power supply integrated circuits; Dengen IC yo koseido anarogu kairo gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Nakamori, A.; Suzuki, T.; Mizoe, K. [Fuji Electric Corporate Research and Development,Ltd., Kanagawa (Japan)

    2000-08-10

    With the recent rapid spread of portable electronic appliances, specification requirements such as compact power supply and long operation with batteries have become severer. Power supply ICs (integrated circuits) are required to reduce power consumption in the circuit and perform high-precision control. To meet these requirements, Fuji Electric develops high-precision CMOS (complementary metal-oxide semiconductor) analog technology. This paper describes three analog circuit technologies of a voltage reference, an operational amplifier and a comparator as circuit components particularly important for the precision of power supply ICs. (author)

  2. A systematic review of publications studies on medical tourism.

    Science.gov (United States)

    Masoud, Ferdosi; Alireza, Jabbari; Mahmoud, Keyvanara; Zahra, Agharahimi

    2013-01-01

    Medical tourism for any study area is complex. Using full articles from other databases, Institute for Scientific Information (ISI), Science Direct, Emerald, Oxford, Magiran, and Scientific Information Database (SID), to examine systematically published articles about medical tourism in the interval 2000-2011 paid. Articles were obtained using descriptive statistics and content analysis categories were analyzed. Among the 28 articles reviewed, 11 cases were a kind of research articles, three cases were case studies in Mexico, India, Hungary, Germany, and Iran, and 14 were case studies, review documents and data were passed. The main topics of study included the definition of medical tourism, medical tourists' motivation and development of medical tourism, ethical issues in medical tourism, and impact on health and medical tourism marketing. The findings indicate the definition of medical tourism in various articles, and medical tourists are motivated. However, most studies indicate the benefits of medical tourism in developing countries and more developed countries reflect the consequences of medical tourism.

  3. High-precision percolation thresholds and Potts-model critical manifolds from graph polynomials

    Science.gov (United States)

    >Jesper Lykke Jacobsen,

    2014-04-01

    The critical curves of the q-state Potts model can be determined exactly for regular two-dimensional lattices G that are of the three-terminal type. This comprises the square, triangular, hexagonal and bow-tie lattices. Jacobsen and Scullard have defined a graph polynomial PB(q, v) that gives access to the critical manifold for general lattices. It depends on a finite repeating part of the lattice, called the basis B, and its real roots in the temperature variable v = eK - 1 provide increasingly accurate approximations to the critical manifolds upon increasing the size of B. Using transfer matrix techniques, these authors computed PB(q, v) for large bases (up to 243 edges), obtaining determinations of the ferromagnetic critical point vc > 0 for the (4, 82), kagome, and (3, 122) lattices to a precision (of the order 10-8) slightly superior to that of the best available Monte Carlo simulations. In this paper we describe a more efficient transfer matrix approach to the computation of PB(q, v) that relies on a formulation within the periodic Temperley-Lieb algebra. This makes possible computations for substantially larger bases (up to 882 edges), and the precision on vc is hence taken to the range 10-13. We further show that a large variety of regular lattices can be cast in a form suitable for this approach. This includes all Archimedean lattices, their duals and their medials. For all these lattices we tabulate high-precision estimates of the bond percolation thresholds pc and Potts critical points vc. We also trace and discuss the full Potts critical manifold in the (q, v) plane, paying special attention to the antiferromagnetic region v < 0. Finally, we adapt the technique to site percolation as well, and compute the polynomials PB(p) for certain Archimedean and dual lattices (those having only cubic and quartic vertices), using very large bases (up to 243 vertices). This produces the site percolation thresholds pc to a precision of the order of 10-9.

  4. Modes and times of caldera resurgence: The Ischia Caldera, Italy, from high-precision archaeomagnetic dating

    Science.gov (United States)

    Vezzoli, Luigina; Principe, Claudia; Malfatti, Jonas; Arrighi, Simone; Tanguy, Jean-Claude; Le Goff, Maxime

    2009-10-01

    Ischia is a well exposed and densely populated late Quaternary caldera in the Campanian magmatic province of Italy. Ischia Caldera experienced an average uplift rate of 3.3 cm/year in the last ca. 30 ka and is still actively resurging. During the last 10 ka, coeval with the resurgence, a volcanic field of alkali-trachytic to trachyandesitic lava domes, lava flows, tuff and scoria rings, and pumice cones developed, mainly on the eastern sector of the caldera, along both resurgence-related faults and regional NNW- and NE-striking faults. In order to improve both our understanding of the recent volcanic history and the evaluation of future risks on Ischia Island, a high-precision archaeomagnetic dating method was applied to the products of 12 volcanic centres with probable age Ischia volcanism occurred in five periods separated by phases of quiescence and coeval with earthquake and landslide events. This fact suggests a pulsating mode of uplifting and deformations of the Ischia resurgence. During the two oldest periods of activity (7200-6800 BC and 4100-2300 BC), resurgence probably produced a dome-shaped structure. Location and geometry of vents suggest the occurrence of magma uprise along the fractures produced by bending of the overburden crustal block. Most of magma was emplaced as intrusions at the interior of the resurgent block, whereas volcanism was represented by very viscous, differentiated, and crystallized lavas that emplaced as domes and high aspect-ratio flows. The resurgent dome caused recurrent lateral collapses that removed about 2.5 km 3 of rocks. During the three youngest periods of activity (1800-1000 BC; 650 BC -355 AD; and 1302 AD), resurgence affected a fault-bounded, asymmetric block. This resulted from both (a) hydrostatic rebound of the crustal block after removal of material involved into huge slope instability triggering an increase in uplift rate, and (b) new influxes of less evolved magma batches into the shallow reservoir that, in turn

  5. Procyon: Constraining Its Temperature Structure with High-Precision Interferometry and 3-D Model Atmospheres

    Science.gov (United States)

    Aufdenberg, J. P.; Ludwig, H.-G.; Kervella, P.

    2004-12-01

    We have fit synthetic visibilities from 3-D (CO5BOLD + PHOENIX) and 1-D (PHOENIX, ATLAS12) model stellar atmospheres for Procyon (F5 IV) to high-precision interferometric data from the VINCI instrument at the VLT Interferometer (K-band) and from the Mark III interferometer (500 nm, 800 nm). These data provide a test of theoretical wavelength-dependent limb-darkening predictions, and therefore Procyon's atmospheric temperature structure. Earlier work (Allende Prieto et al. 2002 ApJ 567, 544) has shown that the temperature structure from a spatially and temporally averaged 3-D hydrodynamical model produces significantly less limb darkening at 500 nm relative to the temperature structure from a 1-D MARCS model atmosphere which uses a mixing-length approximation for convective flux transport. Our direct fits to the interferometric data confirm this prediction, however we find that not all 1-D models fail to reproduce the observations. The key to matching the interferometric data is a shallower temperature gradient than provided by the standard 1-D mixing-length approximation. We find that in addition to our best fitting 3-D hydrodynamical model, a 1-D ATLAS12 model, with an additional free parameter for ``approximate overshooting'', provides the required temperature gradient. We estimate that an interferometric precision better than 0.1% will be required to distinguish between the 3-D model and the ATLAS12 model. This overshooting approximation has been shown to match Solar limb-darkening observations reasonably well (Castelli et al 1997 A&A 324, 432), however published work since using Strömgren photometry of solar-type stars has cast doubt on the importance of overshooting. We have also compared synthetic spectral energy distributions for Procyon to ultraviolet, optical and near-infrared spectrophotometry and find differences from comparisons to Strömgren photometry alone. This work was performed in part contract with the Jet Propulsion Laboratory (JPL) funded by

  6. High-precision measurement of strong-interaction effects in pionic deuterium

    Energy Technology Data Exchange (ETDEWEB)

    Strauch, Thomas

    2009-06-30

    The hadronic ground state shift {epsilon}{sub 1s} and width {gamma}{sub 1s} in pionic deuterium were measured with high precision at the pion factory of the Paul Scherrer Institut (PSI), Switzerland (PSI-Experiment R-06.03). In this experiment the {pi}D(3p-1s) X-ray transition of about 3 keV was measured using a high-resolution Bragg crystal spectrometer equipped with a large-area position sensitive CCD detector. The characteristic X-radiation stems from a de-excitation cascade of the pionic atom. In order to produce an intense X-ray source, the cyclotron trap was used to stop pions in a cryogenic D{sub 2} target after winding up the pion beam in a magnetic field. The hadronic shift {epsilon}{sub 1s} is obtained from the measured transition energy by comparison to the pure electromagnetic value, where the determination of the broadening {gamma}{sub 1s} requires the precise knowledge of the spectrometer response, obtained from measurements of narrow X-ray transitions from highly ionised atoms, produced in an electron cyclotron resonance ion trap. As the formation rate is assumed to be density dependent, the {pi}D(3p-1s) X-ray energy was measured at three different D{sub 2} pressures. Another cascade process (Coulomb de-excitation) transforms the energy release of de-excitation steps into kinetic energy of the collision partners leading to a Doppler broadening of subsequent X-ray transitions. The hadronic broadening {gamma}{sub 1s} is only obtained after deconvolution of the spectrometer response function and the contributions from Doppler broadening. No energy dependence of the {pi}D(3p-1s) was found, and it is concluded that radiative de-excitation from molecular states is negligible within the experimental accuracy. Hence, the result for the shift reads {epsilon}{sub 1s} = (-2.325{+-}0.031) eV, corresponding to an accuracy of 1.3% and represents the average of the three measured densities. The uncertainty is dominated by the accuracy of the gallium K{alpha}{sub 2

  7. Influence of sulfur-bearing polyatomic species on high precision measurements of Cu isotopic composition

    Science.gov (United States)

    Pribil, M.J.; Wanty, R.B.; Ridley, W.I.; Borrok, D.M.

    2010-01-01

    An increased interest in high precision Cu isotope ratio measurements using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) has developed recently for various natural geologic systems and environmental applications, these typically contain high concentrations of sulfur, particularly in the form of sulfate (SO42-) and sulfide (S). For example, Cu, Fe, and Zn concentrations in acid mine drainage (AMD) can range from 100??g/L to greater than 50mg/L with sulfur species concentrations reaching greater than 1000mg/L. Routine separation of Cu, Fe and Zn from AMD, Cu-sulfide minerals and other geological matrices usually incorporates single anion exchange resin column chromatography for metal separation. During chromatographic separation, variable breakthrough of SO42- during anion exchange resin column chromatography into the Cu fractions was observed as a function of the initial sulfur to Cu ratio, column properties, and the sample matrix. SO42- present in the Cu fraction can form a polyatomic 32S-14N-16O-1H species causing a direct mass interference with 63Cu and producing artificially light ??65Cu values. Here we report the extent of the mass interference caused by SO42- breakthrough when measuring ??65Cu on natural samples and NIST SRM 976 Cu isotope spiked with SO42- after both single anion column chromatography and double anion column chromatography. A set of five 100??g/L Cu SRM 976 samples spiked with 500mg/L SO42- resulted in an average ??65Cu of -3.50?????5.42??? following single anion column separation with variable SO42- breakthrough but an average concentration of 770??g/L. Following double anion column separation, the average SO42-concentration of 13??g/L resulted in better precision and accuracy for the measured ??65Cu value of 0.01?????0.02??? relative to the expected 0??? for SRM 976. We conclude that attention to SO42- breakthrough on sulfur-rich samples is necessary for accurate and precise measurements of ??65Cu and may require

  8. Correlation analysis of high precision blood flow imaging in secondary parathyroid function in maintenance hemodialysis patients

    Institute of Scientific and Technical Information of China (English)

    Wen-Ze Du; Le Chen; Xiao-Yun Wu

    2016-01-01

    Objective:To investigate the value of high precision blood flow imaging (Fine-Flow) in secondary parathyroid function (SHPT) in patients with maintenance hemodialysis (MHD). Methods: A total of 95 MHD patients with SHPT in our hospital from January 2015 to June 2016 were selected as the research object. According to the Fine-Flow examination of parathyroid gland, 73 cases were divided into display group, 22 cases were not shown; Display group according to the hyperplasia of parathyroid diameter were divided into 1.5 cm group of 17 cases; display group according to the blood flow into the rich group of 41 cases, not rich group of 32 cases; according to whether calcification were divided into calcification group of 43 cases, non calcified group of 30 cases. CDFI was used for the anterior region of neck transverse and longitudinal scanning, check the thyroid and around the dorsal lobes.The size, echo, lesion number and blood flow were measured, parathyroid hormone (PTH), serum calcium (Ca), phosphorus (P), and calculate the Ca and P product (Ca×P) were measured.Results: PTH and Ca of the display group were significantly higher than that of the non display group, and differences in P and Ca×P were not statistically significant; Parathyroid diameter >1.5 cm PTH levels were significantly higher than the other three groups, diameter 1-1.5 cm group and >1.5 cm group Ca, diameter Ca×P was higher than that in group <5 cm and 0.5-1.0 cm group, difference in P of four groups was not statistical significant; group PTH, P, abundant blood flow Ca×P were not significantly higher than the rich group, difference in P of two groups was no statistical significance; group Ca was significantly higher than that of calcification calcification group, differences in PTH, P, Ca×P of the two groups were not statistically significant.Conclusions:MHD patients with SHPT, parathyroid Fine-Flow display rate is high, and has the characteristic performance. Its operation is simple, non

  9. Biologic Discontinuations Studies: A Systematic Review of Methods

    Science.gov (United States)

    Yoshida, Kazuki; Sung, Yoon-Kyoung; Kavanaugh, Arthur; Bae, Sang-Cheol; Weinblatt, Michael E.; Kishimoto, Mitsumasa; Matsui, Kazuo; Tohma, Shigeto; Solomon, Daniel H.

    2016-01-01

    Objectives We conducted a systematic review to assess the design and “failure definition” in studies of biologic discontinuation in rheumatoid arthritis (RA). Methods We found 403 studies on PubMed, and included 9 published papers and 5 abstracts from scientific meetings. We used a structured extraction form to collect information regarding study design and outcome (failure) definition. Results Three types of studies were found: randomized controlled trials, long-term extension studies of clinical trials, and prospective discontinuation studies. The largest study had 196 subjects in the discontinuation arm. Most studies allowed concomitant use of non-biologic drugs at biologic discontinuation. Heterogeneity was also found in the failure definition. Although all studies used measures of disease activity, the threshold for failure and the time point of assessment differed among studies. Few studies incorporated changing use of non-biologic drugs or glucocorticoids into the failure definition. Conclusions Although many studies have examined the outcome of biologic discontinuation, they have all been relatively small. Typical practice studies from registries may add important information, but will likely need to rely on a broader failure definition. PMID:23723316

  10. Shandong Hengyuan 200,000 tonnes of High-Precision Copper Product Project is Making Smooth Progress

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

    <正>Shandong Hengyuan Copper Co., Ltd is an emerging copper product processing enterprise in China, the company plans to invest 1 billion yuan to construct 200,000 t/a high precision copper product, which includes: 20,000 tones of precision copper tube and copper alloy tube, 10,000 tonnes of railway electrification copper

  11. Present status and future of high-precision image guided adaptive brachytherapy for cervix carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Poetter, Richard; Kirisits, Christian; Fidarova, Elena F.; Dimopoulos, Johannes C. A.; Berger, Daniel; Tanderup, Kari; Lindegaard, Jacob C. (Dept. of Radiotherapy Medical Univ. of Vienna, General Hospital Vienna, Wien (Austria))

    2008-08-15

    Introduction. Image guided adaptive brachytherapy (IGABT) for cervical cancer, using mainly MRI, is an evolving method, increasingly replacing the 2D approach based on conventional radiography. During the complex 4D chain of this procedure image-assistance is provided for disease assessment, provisional treatment planning ('pre-planning'), applicator placement and reconstruction, as well as for contouring, definitive treatment planning and quality control of dose delivery. With IGABT changes of topography adjacent to the applicator, caused by tumour regression, oedema, organ changes and dilation are identified. Thus, the CTV for IGABT is primarily based on the tumour volume at the time of BT and takes into account both time and spatial domains. IGABT requires systematic concepts for target, OAR, biological modelling, DVH analysis, and dose-volume-adaptation. Methods and Results. This report focuses on the advantages and uncertainties, dose-effect relations and clinical results of the IGABT procedure addressing the current status and future perspectives. Uncertainties during the 4D chain of IGABT are mainly related to target contouring, applicator reconstruction, as well as to inter-fraction, intra-fraction and inter-application variability, as caused by tumour response and organ changes. Different from EBRT where set-up uncertainties are compensated by adding a margin to the CTV, no margins to the lateral and anterior-posterior directions can be used for IGABT. Discussion. By 3D treatment planning for IGABT significant improvement of the DVH parameters is achieved compared to 2D library plans. In small tumours the benefit is primarily obtained by a decrease of dose to nearby OAR while in large tumours the use of supplementary interstitial techniques and optimization may double the target volume that can be treated at a therapeutic dose level. The clinical impact of IGABT could recently be demonstrated by the establishment of some correlations between

  12. An engineered design of a diffractive mask for high precision astrometry

    Science.gov (United States)

    Dennison, Kaitlin; Ammons, S. Mark; Garrel, Vincent; Marin, Eduardo; Sivo, Gaetano; Bendek, Eduardo; Guyon, Oliver

    2016-07-01

    AutoCAD, Zemax Optic Studio 15, and Interactive Data Language (IDL) with the Proper Library are used to computationally model and test a diffractive mask (DiM) suitable for use in the Gemini Multi-Conjugate Adaptive Optics System (GeMS) on the Gemini South Telescope. Systematic errors in telescope imagery are produced when the light travels through the adaptive optics system of the telescope. DiM is a transparent, flat optic with a pattern of miniscule dots lithographically applied to it. It is added ahead of the adaptive optics system in the telescope in order to produce diffraction spots that will encode systematic errors in the optics after it. Once these errors are encoded, they can be corrected for. DiM will allow for more accurate measurements in astrometry and thus improve exoplanet detection. The mechanics and physical attributes of the DiM are modeled in AutoCAD. Zemax models the ray propagation of point sources of light through the telescope. IDL and Proper simulate the wavefront and image results of the telescope. Aberrations are added to the Zemax and IDL models to test how the diffraction spots from the DiM change in the final images. Based on the Zemax and IDL results, the diffraction spots are able to encode the systematic aberrations.

  13. Activity of Changbaishan Tianchi Volcano Since Late Pleistocene--The Constrain From Geochronology of High Precision U- Series Tims Method

    Institute of Scientific and Technical Information of China (English)

    Wang Fei; Chen Wenji; Zhang Zhonglu; Hu Yutai; Peng Zicheng

    2000-01-01

    11 samples of lava and pumice from the cone of Changbaishan Tianchi Volcano, Jiling, China, were dated by using high precision U - series TIMS method. We conclude that the bottom of the cone formed before 350 ka, the middle part in 70~80 ka, the upper during 20~ 1ka, and the top less than 1ka, and the age based periods of the volcano eruption since Late Pleistocene is given as follows: > 350ka, 70ka, 18 ~ 25ka, 10ka, 4C5ka, 1~0.75ka, which may offer the basis for the study of volcanic disaster in future. In addition, the principle of dating young volcanic rocks by using U - series TIMS method is introduced briefly. Differentiation characteristics of U and Th in different minerals of the volcanic rocks are discussed, and the ability producing isochrons, based on U and Th differentiation, are discussed. In the last part of the paper,the closure of samples to the elements U and Th, which is important for age results, is discussed by using (234U/238U)radioactivity ratio which can be used to monitor if the samples have been weathered or eroded or leached since the time they formed. In this study, all samples have (234U/238U) activity ratios within 1% of secular equilibrium ((234U/238U) radioactivity ratios are unity), indicating no disturbance of the 234U- 238U system. All of these discussions show that the TIMS method is good to date Tianchi volcanics and the results are reliable.

  14. High-precision 40Ar/39Ar ages for the Jehol fossil-bearing formations in SE China

    Science.gov (United States)

    Chang, S.; Zhang, H.; Hemming, S. R.; Fang, Y.; Mesko, G. T.

    2009-12-01

    The Jehol Biota, defined as the characteristic Eosestheria-Ephemeropsis-Lycoptera assemblage, is known to be widely distributed in East Asia. The fossils of the Jehol Biota are magnificent, exquisitely preserved and extraordinarily diverse. Since the 1990s, abundant and varied fossils, including plants, insects, salamanders, dinosaurs, pterosaurs, choristoderes, birds, mammals and freshwater invertebrates, have been discovered from the Dabeigou, Yixian and Jiufotang Formations in Inner Mongolia, and Liaoning and Hebei Provinces of NE China. Each of these Jehol fossil-bearing formations has preserved a distinct assemblage of invertebrate and vertebrate fossils. Based on major invertebrates groups, the Jehol Biota has been divided into three developing stages and a hypothesis about its distribution and spread has been proposed. There is a clear progression towards greater diversity through the three phases and it corresponds to a progressive paleogeographic expansion through time. In addition to their extensive distribution in Inner Mongolia and NE China, other strata that contain Jehol related fossils have been identified in the central and most provinces of eastern China, the Korean Peninsula, Mongolia and Siberia. However, the detailed correlation between the classic Jehol outcrops and the less-studied localities requires further work, including high-resolution ages. We are analyzing sixteen volcanic samples from Zhejiang and Anhui Provinces to establish a high-precision chronostratigraphy for the less-studied localities across SE China and adjacent regions. Our work will provide important data to test the timing and the duration of three phases of the Jehol radiation. Furthermore, the age results will allow us to understand the temporal relationship among the Jehol localities and test if the later phases of the Jehol radiation had broader geographic distributions, as inferred from existing collections.

  15. Matrix effects of calcium on high-precision sulfur isotope measurement by multiple-collector inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Liu, Chenhui; Bian, Xiao-Peng; Yang, Tao; Lin, An-Jun; Jiang, Shao-Yong

    2016-05-01

    Multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) has been successfully applied in the rapid and high-precision measurement for sulfur isotope ratios in recent years. During the measurement, the presence of matrix elements would affect the instrumental mass bias for sulfur and these matrix-induced effects have aroused a lot of researchers' interest. However, these studies have placed more weight on highlighting the necessity for their proposed correction protocols (e.g., chemical purification and matrix-matching) while less attention on the key property of the matrix element gives rise to the matrix effects. In this study, four groups of sulfate solutions, which have different concentrations of sulfur (0.05-0.60mM) but a constant sequence of atomic calcium/sulfur ratios (0.1-50), are investigated under wet (solution) and dry (desolvation) plasma conditions to make a detailed evaluation on the matrix effects from calcium on sulfur isotope measurement. Based on a series of comparative analyses, we indicated that, the matrix effects of calcium on both measured sulfur isotope ratios and detected (32)S signal intensities are dependent mainly on the absolute calcium concentration rather than its relative concentration ratio to sulfur (i.e., atomic calcium/sulfur ratio). Also, for the same group of samples, the matrix effects of calcium under dry plasma condition are much more significant than that of wet plasma. This research affords the opportunity to realize direct and relatively precise sulfur isotope measurement for evaporite gypsum, and further provides some suggestions with regard to sulfur isotope analytical protocols for sedimentary pore water.

  16. Frontiers of QC Laser spectroscopy for high precision isotope ratio analysis of greenhouse gases

    Science.gov (United States)

    Emmenegger, Lukas; Mohn, Joachim; Harris, Eliza; Eyer, Simon; Ibraim, Erkan; Tuzson, Béla

    2016-04-01

    An important milestone for laser spectroscopy was achieved when isotope ratios of greenhouse gases were reported at precision levels that allow addressing research questions in environmental sciences. Real-time data with high temporal resolution at moderate cost and instrument size make the optical approach highly attractive, complementary to the well-established isotope-ratio mass-spectrometry (IRMS) method. Especially appealing, in comparison to IRMS, is the inherent specificity to structural isomers having the same molecular mass. Direct absorption in the MIR in single or dual QCL configuration has proven highly reliable for the sta-ble isotopes of CO2, N2O and CH4. The longest time series of real-time measurements is currently available for δ13C and δ18O in CO2 at the high-alpine station Jung-fraujoch. At this well-equipped site, QCL based direct absorption spectroscopy (QCLAS) measurements are ongoing since 2008 1,2. Applications of QCLAS for N2O and CH4 stable isotopes are considerably more challenging because of the lower atmospheric mixing ratios, especially for the less abundant species, such as N218O and CH3D. For high precision (mental applications illustrating the highly valuable information that isotope ratios of atmospheric trace gases can carry. For example, the intramolecular distribution of 15N in N2O gives important information on the geochemical cycle of N2O4-6, while the analysis of δ13C and δ D in CH4 may be applied to disentangle microbial, fossil and landfill sources 7. 1 Sturm, P., Tuzson, B., Henne, S. & Emmenegger, L. Tracking isotopic signatures of CO2 at the high altitude site Jungfraujoch with laser spectroscopy: Analytical improvements and representative re-sults. Atmospheric Measurement Techniques 6, 1659-1671 (2013). 2 Tuzson, B. et al. Continuous isotopic composition measurements of tropospheric CO2 at Jungfraujoch (3580 m a.s.l.), Switzerland: real-time observation of regional pollution events. Atmospheric Chemistry and Physics

  17. Systematic study of survival probability of excited superheavy nuclei

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The stability of excited superheavy nuclei (SHN) with 100 Z 134 against neutron emission and fission is investigated by using a statistical model. In particular, a systematic study of the survival probability against fission in the 1n-channel of these SHN is made. The present calculations consistently take the neutron separation energies and shell correction energies from the calculated results of the finite range droplet model which predicts an island of stability of SHN around Z = 115 and N = 179. It turns out that this island of stability persists for excited SHN in the sense that the calculated survival probabilities in the 1n-channel of excited SHN at the optimal excitation energy are maximized around Z = 115 and N = 179. This indicates that the survival probability in the 1n-channel is mainly determined by the nuclear shell effects.

  18. Systematic study of source mask optimization and verification flows

    Science.gov (United States)

    Ben, Yu; Latypov, Azat; Chua, Gek Soon; Zou, Yi

    2012-06-01

    Source mask optimization (SMO) emerged as powerful resolution enhancement technique (RET) for advanced technology nodes. However, there is a plethora of flow and verification metrics in the field, confounding the end user of the technique. Systemic study of different flows and the possible unification thereof is missing. This contribution is intended to reveal the pros and cons of different SMO approaches and verification metrics, understand the commonality and difference, and provide a generic guideline for RET selection via SMO. The paper discusses 3 different type of variations commonly arise in SMO, namely pattern preparation & selection, availability of relevant OPC recipe for freeform source and finally the metrics used in source verification. Several pattern selection algorithms are compared and advantages of systematic pattern selection algorithms are discussed. In the absence of a full resist model for SMO, alternative SMO flow without full resist model is reviewed. Preferred verification flow with quality metrics of DOF and MEEF is examined.

  19. A systematic review of fast food access studies.

    Science.gov (United States)

    Fleischhacker, S E; Evenson, K R; Rodriguez, D A; Ammerman, A S

    2011-05-01

    The frequent consumption of energy-dense fast food is associated with increased body mass index. This systematic review aims to examine the methodology and current evidence on fast food access and its associations with outcomes. Six databases were searched using terms relating to fast food. Only peer-reviewed studies published in English during a 10-year period, with data collection and analysis regarding fast food access were included. Forty articles met the aforementioned criteria. Nearly half of the studies (n = 16) used their own set of features to define fast food. Studies predominantly examined the relationship between fast food access and socioeconomic factors (n = 21) and 76% indicated fast food restaurants were more prevalent in low-income areas compared with middle- to higher-income areas. Ten of 12 studies found fast food restaurants were more prevalent in areas with higher concentrations of ethnic minority groups in comparison with Caucasians. Six adult studies found higher body mass index was associated with living in areas with increased exposure to fast food; four studies, however, did not find associations. Further work is needed to understand if and how fast food access impacts dietary intake and health outcomes; and if fast food access has disparate socioeconomic, race/ethnicity and age associations. © 2010 The Authors. obesity reviews © 2010 International Association for the Study of Obesity.

  20. High-precision photometry by telescope defocussing - II. The transiting planetary system WASP-4

    DEFF Research Database (Denmark)

    Southworth, J.; Hinse, T. C.; Burgdorf, M. J.;

    2009-01-01

    We present and analyse light curves of four transits of the Southern hemisphere extrasolar planetary system WASP-4, obtained with a telescope defocused so the radius of each point spread function was 17 arcsec (44 pixels). This approach minimizes both random and systematic errors, allowing us...... to achieve scatters of between 0.60 and 0.88 mmag per observation over complete transit events. The light curves are augmented by published observations and analysed using the JKTEBOP code. The results of this process are combined with theoretical stellar model predictions to derive the physical properties...... of the WASP-4 system. We find that the mass and radius of the planet are Mb = 1.289+0.090-0.090+0.039-0.000MJup and Rb = 1.371+0.032-0.035+0.021-0.000RJup, respectively (statistical and systematic uncertainties). These quantities give a surface gravity and density of gb = 17.03+0.97-0.54ms-2 and ρb = 0...

  1. Towards an unbiased filter routine to determine precipitation and evapotranspiration from high precision lysimeter measurements

    Science.gov (United States)

    Peters, Andre; Groh, Jannis; Schrader, Frederik; Durner, Wolfgang; Vereecken, Harry; Pütz, Thomas

    2017-06-01

    Weighing lysimeters are considered to be the best means for a precise measurement of water fluxes at the interface between the soil-plant system and the atmosphere. Any decrease of the net mass of the lysimeter can be interpreted as evapotranspiration (ET), any increase as precipitation (P). However, the measured raw data need to be filtered to separate real mass changes from noise. Such filter routines typically apply two steps: (i) a low pass filter, like moving average, which smooths noisy data, and (ii) a threshold filter that separates significant from insignificant mass changes. Recent developments of these filters have identified and solved some problems regarding bias in the data processing. A remaining problem is that each change in flow direction is accompanied with a systematic flow underestimation due to the threshold scheme. In this contribution, we analyze this systematic effect and show that the absolute underestimation is independent of the magnitude of a flux event. Thus, for small events, like dew or rime formation, the relative error is high and can reach the same magnitude as the flux itself. We develop a heuristic solution to the problem by introducing a so-called ;snap routine;. The routine is calibrated and tested with synthetic flux data and applied to real measurements obtained with a precision lysimeter for a 10-month period. The heuristic snap routine effectively overcomes these problems and yields an almost unbiased representation of the real signal.

  2. Pharmacogenomics Bias - Systematic distortion of study results by genetic heterogeneity

    Directory of Open Access Journals (Sweden)

    Zietemann, Vera

    2008-04-01

    Full Text Available Background: Decision analyses of drug treatments in chronic diseases require modeling the progression of disease and treatment response beyond the time horizon of clinical or epidemiological studies. In many such models, progression and drug effect have been applied uniformly to all patients; heterogeneity in progression, including pharmacogenomic effects, has been ignored. Objective: We sought to systematically evaluate the existence, direction and relative magnitude of a pharmacogenomics bias (PGX-Bias resulting from failure to adjust for genetic heterogeneity in both treatment response (HT and heterogeneity in progression of disease (HP in decision-analytic studies based on clinical study data. Methods: We performed a systematic literature search in electronic databases for studies regarding the effect of genetic heterogeneity on the validity of study results. Included studies have been summarized in evidence tables. In the case of lacking evidence from published studies we sought to perform our own simulation considering both HT and HP. We constructed two simple Markov models with three basic health states (early-stage disease, late-stage disease, dead, one adjusting and the other not adjusting for genetic heterogeneity. Adjustment was done by creating different disease states for presence (G+ and absence (G- of a dichotomous genetic factor. We compared the life expectancy gains attributable to treatment resulting from both models and defined pharmacogenomics bias as percent deviation of treatment-related life expectancy gains in the unadjusted model from those in the adjusted model. We calculated the bias as a function of underlying model parameters to create generic results. We then applied our model to lipid-lowering therapy with pravastatin in patients with coronary atherosclerosis, incorporating the influence of two TaqIB polymorphism variants (B1 and B2 on progression and drug efficacy as reported in the DNA substudy of the REGRESS

  3. A systematic review of publications studies on medical tourism

    Science.gov (United States)

    Masoud, Ferdosi; Alireza, Jabbari; Mahmoud, Keyvanara; Zahra, Agharahimi

    2013-01-01

    Introduction: Medical tourism for any study area is complex. Materials and Methods: Using full articles from other databases, Institute for Scientific Information (ISI), Science Direct, Emerald, Oxford, Magiran, and Scientific Information Database (SID), to examine systematically published articles about medical tourism in the interval 2000-2011 paid. Articles were obtained using descriptive statistics and content analysis categories were analyzed. Results: Among the 28 articles reviewed, 11 cases were a kind of research articles, three cases were case studies in Mexico, India, Hungary, Germany, and Iran, and 14 were case studies, review documents and data were passed. The main topics of study included the definition of medical tourism, medical tourists’ motivation and development of medical tourism, ethical issues in medical tourism, and impact on health and medical tourism marketing. Conclusion: The findings indicate the definition of medical tourism in various articles, and medical tourists are motivated. However, most studies indicate the benefits of medical tourism in developing countries and more developed countries reflect the consequences of medical tourism. PMID:24251287

  4. High-precision analyses of Lyα damping wing of gamma-ray bursts in the reionization era: On the controversial results from GRB 130606A at z = 5.91

    Science.gov (United States)

    Totani, Tomonori; Aoki, Kentaro; Hattori, Takashi; Kawai, Nobuyuki

    2016-02-01

    The unprecedentedly bright afterglow of Swift GRB 130606A at z = 5.91 gave us a unique opportunity to probe the reionization era through high-precision analyses of the redward damping wing of Lyα absorption, but the reported constraints on the neutral hydrogen fraction (f_{H I}) in intergalactic medium (IGM) derived from spectra taken by different telescopes are in contradiction to each other. Here we examine the origin of this discrepancy by analyzing the spectrum taken by the Very Large Telescope (VLT) with our own analysis code previously used to fit the Subaru spectrum. Though the VLT team reported no evidence for IGM H I using the VLT spectrum, we confirm our previous result of preferring non-zero IGM H I (the best fit f_{H I} ˜ 0.06, when IGM H I extends to the GRB redshift). The fit residuals of the VLT spectrum using the model without IGM H I show the same systematic trend as the Subaru spectrum. We consider that the likely origin of the discrepancy between the two teams is the difference of the wavelength ranges adopted in the fittings; our wavelength range is wider than that of the VLT team, and also we avoided the shortest wavelength range of deep Lyα absorption (λobs < 8426 Å), because this region is dominated by H I in the host galaxy and the systematic uncertainty about host H I velocity distribution is large. We also study the sensitivity of these results to the adopted Lyα cross-section formulae, ranging from the classical Lorentzian function to the most recent one taking into account fully quantum mechanical scattering. It is found that the preference for non-zero IGM H I is robust against the choice of the cross-section formulae, but it is quantitatively not negligible and hence one should be careful in future analyses.

  5. High-precision position estimation in PET using artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Mateo, F. [Digital Systems Design Group (DSD), Instituto de las Tecnologias de la Informacion y de las Comunicaciones Avanzadas (ITACA), Universidad Politecnica de Valencia, Camino de Vera s/n, 46022 Valencia (Spain)], E-mail: fermaji@upvnet.upv.es; Aliaga, R.J.; Ferrando, N.; Martinez, J.D.; Herrero, V.; Lerche, Ch.W.; Colom, R.J.; Monzo, J.M.; Sebastia, A.; Gadea, R. [Digital Systems Design Group (DSD), Instituto de las Tecnologias de la Informacion y de las Comunicaciones Avanzadas (ITACA), Universidad Politecnica de Valencia, Camino de Vera s/n, 46022 Valencia (Spain)

    2009-06-01

    Traditionally, the most popular technique to predict the impact position of gamma photons on a PET detector has been Anger's logic. However, it introduces nonlinearities that compress the light distribution, reducing the useful field of view and the spatial resolution, especially at the edges of the scintillator crystal. In this work, we make use of neural networks to address a bias-corrected position estimation from real stimulus obtained from a 2D PET system setup. The preprocessing and data acquisition were performed by separate custom boards, especially designed for this application. The results show that neural networks yield a more uniform field of view while improving the systematic error and the spatial resolution. Therefore, they stand as a better performing and readily available alternative to classic positioning methods.

  6. Advanced approaches to high precision MEMS metrology based on interferometric,confocal,and tactile techniques

    Institute of Scientific and Technical Information of China (English)

    Peter Lehmenn

    2008-01-01

    Geometrical features of micro-systems can be determined by either tactile or optical profiling techniques,which show different non-linear transfer characteristics.This has to be considered especially,if the instrumcnts operate close to their physical limitations.Depending on the specific measuring task either point-wise or areal optical measurement may be advantageous.Hence,examples for boIh approaches are discussed.Furthermore,systematic effects,which are related to the measuring principle have to be taken into account,e.g.if sharp edges or slopes ale present on the measuring object.As it is shown,for white-light interferometry these difficulties can be solved by a two-wavelength technique.

  7. High Precision Astrometry with MICADO at the European Extremely Large Telescope

    CERN Document Server

    Trippe, S; Eisenhauer, F; Förster-Schreiber, N M; Fritz, T K; Genzel, R

    2009-01-01

    In this article we identify and discuss various statistical and systematic effects influencing the astrometric accuracy achievable with MICADO, the near-infrared imaging camera proposed for the 42-metre European Extremely Large Telescope (E-ELT). These effects are instrumental (e.g. geometric distortion), atmospheric (e.g. chromatic differential refraction), and astronomical (reference source selection). We find that there are several phenomena having impact on ~100 micro-arcsec scales, meaning they can be substantially larger than the theoretical statistical astrometric accuracy of an optical/NIR 42m-telescope. Depending on type, these effects need to be controlled via dedicated instrumental design properties or via dedicated calibration procedures. We conclude that if this is done properly, astrometric accuracies of 40 micro-arcsec or better - with 40 micro-arcsec/year in proper motions corresponding to ~20 km/s at 100 kpc distance - can be achieved in one epoch of actual observations

  8. High precision measurements of arsenic and phosphorous implantation dose in silicon by secondary ion mass spectrometry

    CERN Document Server

    Chi, P H; McKinley, J M; Stevie, F A; Granger, C N

    2002-01-01

    The metrology section of the 1999 International Technology Roadmap for Semiconductors specifies in-line dopant profile concentration precision requirements ranging from a value of 5% in 1999 to a value of 2% in 2008. These values are to be accomplished with ''low systematic error.'' Secondary ion mass spectrometry (SIMS) has demonstrated the capability to meet these requirements for B, As, and P. However, the detailed analytical protocols required to achieve these goals have not been completely specified. This article reports the parameters that must be controlled to make highly repeatable dose measurements of As and P implants in Si with magnetic sector SIMS instruments. Instrument conditions that were investigated include analytical species, matrix ion species, energy bandpass, and sample holder design. With optimized settings, we demonstrate the ability to distinguish As or P implant doses differing by 5%.

  9. A Systematic Review of Immunological Studies of Erythema Nodosum Leprosum

    Science.gov (United States)

    Polycarpou, Anastasia; Walker, Stephen L.; Lockwood, Diana N. J.

    2017-01-01

    Erythema nodosum leprosum (ENL) is a painful inflammatory complication of leprosy occurring in 50% of lepromatous leprosy patients and 5–10% of borderline lepromatous patients. It is a significant cause of economic hardship, morbidity and mortality in leprosy patients. Our understanding of the causes of ENL is limited. We performed a systematic review of the published literature and critically evaluated the evidence for the role of neutrophils, immune complexes (ICs), T-cells, cytokines, and other immunological factors that could contribute to the development of ENL. Searches of the literature were performed in PubMed. Studies, independent of published date, using samples from patients with ENL were included. The search revealed more than 20,000 articles of which 146 eligible studies were included in this systematic review. The studies demonstrate that ENL may be associated with a neutrophilic infiltrate, but it is not clear whether it is an IC-mediated process or that the presence of ICs is an epiphenomenon. Increased levels of tumor necrosis factor-α and other pro-inflammatory cytokines support the role of this cytokine in the inflammatory phase of ENL but not necessarily the initiation. T-cell subsets appear to be important in ENL since multiple studies report an increased CD4+/CD8+ ratio in both skin and peripheral blood of patients with ENL. Microarray data have identified new molecules and whole pathophysiological pathways associated with ENL and provides new insights into the pathogenesis of ENL. Studies of ENL are often difficult to compare due to a lack of case definitions, treatment status, and timing of sampling as well as the use of different laboratory techniques. A standardized approach to some of these issues would be useful. ENL appears to be a complex interaction of various aspects of the immune system. Rigorous clinical descriptions of well-defined cohorts of patients and a systems biology approach using available technologies such as genomics

  10. High-speed, high-precision thermal printing heads for bar code printers; Kosoku koseisai bar cord printer yo TPH

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    Thermal printing heads (TPHs), having the world's first resolution of 24 dots/mm and printing speed of 254 mm/s, have been developed. The high-precision, high-durability TPH is realized, based on the high-precision techniques as one of the company's strong areas, combined with the techniques for high power-resistant film structure and high wear-resistant protective film. At the same time, the structure of high thermal conductivity and thermal efficiency is adopted, to control heat accumulation and realize high-quality images. It is expected to find wide use in various areas, centered by distribution industry, e.g., for bar code label printers, and name plate, postal card and name card printing, with the standardized recording width of A6 size and resolution of 8 to 24 dots/mm. (translated by NEDO)

  11. An automatic high precision registration method between large area aerial images and aerial light detection and ranging data

    Science.gov (United States)

    Du, Q.; Xie, D.; Sun, Y.

    2015-06-01

    The integration of digital aerial photogrammetry and Light Detetion And Ranging (LiDAR) is an inevitable trend in Surveying and Mapping field. We calculate the external orientation elements of images which identical with LiDAR coordinate to realize automatic high precision registration between aerial images and LiDAR data. There are two ways to calculate orientation elements. One is single image spatial resection using image matching 3D points that registered to LiDAR. The other one is Position and Orientation System (POS) data supported aerotriangulation. The high precision registration points are selected as Ground Control Points (GCPs) instead of measuring GCPs manually during aerotriangulation. The registration experiments indicate that the method which registering aerial images and LiDAR points has a great advantage in higher automation and precision compare with manual registration.

  12. Economic Studies in Motor Neurone Disease: A Systematic Methodological Review.

    Science.gov (United States)

    Moore, Alan; Young, Carolyn A; Hughes, Dyfrig A

    2017-04-01

    Motor neurone disease (MND) is a devastating condition which greatly diminishes patients' quality of life and limits life expectancy. Health technology appraisals of future interventions in MND need robust data on costs and utilities. Existing economic evaluations have been noted to be limited and fraught with challenges. The aim of this study was to identify and critique methodological aspects of all published economic evaluations, cost studies, and utility studies in MND. We systematically reviewed all relevant published studies in English from 1946 until January 2016, searching the databases of Medline, EMBASE, Econlit, NHS Economic Evaluation Database (NHS EED) and the Health Economics Evaluation Database (HEED). Key data were extracted and synthesised narratively. A total of 1830 articles were identified, of which 15 economic evaluations, 23 cost and 3 utility studies were included. Most economic studies focused on riluzole (n = 9). Six studies modelled the progressive decline in motor function using a Markov design but did not include mutually exclusive health states. Cost estimates for a number of evaluations were based on expert opinion and were hampered by high variability and location-specific characteristics. Few cost studies reported disease-stage-specific costs (n = 3) or fully captured indirect costs. Utilities in three studies of MND patients used the EuroQol EQ-5D questionnaire or standard gamble, but included potentially unrepresentative cohorts and did not consider any health impacts on caregivers. Economic evaluations in MND suffer from significant methodological issues such as a lack of data, uncertainty with the disease course and use of inappropriate modelling framework. Limitations may be addressed through the collection of detailed and representative data from large cohorts of patients.

  13. High precision single-cluster Monte Carlo measurement of the critical exponents of the classical 3D Heisenberg model

    CERN Document Server

    Holm, C

    1992-01-01

    We report measurements of the critical exponents of the classical three-dimensional Heisenberg model on simple cubic lattices of size $L^3$ with $L$ = 12, 16, 20, 24, 32, 40, and 48. The data was obtained from a few long single-cluster Monte Carlo simulations near the phase transition. We compute high precision estimates of the critical coupling $K_c$, Binder's parameter $U^* and the critical exponents $\

  14. An automatic high precision registration method between large area aerial images and aerial light detection and ranging data

    OpenAIRE

    Du, Q.; Xie, D; Sun, Y.

    2015-01-01

    The integration of digital aerial photogrammetry and Light Detetion And Ranging (LiDAR) is an inevitable trend in Surveying and Mapping field. We calculate the external orientation elements of images which identical with LiDAR coordinate to realize automatic high precision registration between aerial images and LiDAR data. There are two ways to calculate orientation elements. One is single image spatial resection using image matching 3D points that registered to LiDAR. The other o...

  15. Characteristics of Qualitative Descriptive Studies: A Systematic Review.

    Science.gov (United States)

    Kim, Hyejin; Sefcik, Justine S; Bradway, Christine

    2017-02-01

    Qualitative description (QD) is a term that is widely used to describe qualitative studies of health care and nursing-related phenomena. However, limited discussions regarding QD are found in the existing literature. In this systematic review, we identified characteristics of methods and findings reported in research articles published in 2014 whose authors identified the work as QD. After searching and screening, data were extracted from the sample of 55 QD articles and examined to characterize research objectives, design justification, theoretical/philosophical frameworks, sampling and sample size, data collection and sources, data analysis, and presentation of findings. In this review, three primary findings were identified. First, although there were some inconsistencies, most articles included characteristics consistent with the limited available QD definitions and descriptions. Next, flexibility or variability of methods was common and effective for obtaining rich data and achieving understanding of a phenomenon. Finally, justification for how a QD approach was chosen and why it would be an appropriate fit for a particular study was limited in the sample and, therefore, in need of increased attention. Based on these findings, recommendations include encouragement to researchers to provide as many details as possible regarding the methods of their QD studies so that readers can determine whether the methods used were reasonable and effective in producing useful findings. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  16. Evaluation of a high-precision gear measuring machine for helix measurement using helix and wedge artifacts

    Science.gov (United States)

    Taguchi, Tetsuya; Kondo, Yohan

    2016-08-01

    High-precision gears are required for advanced motion and power transmission. The reliability of the measured value becomes important as the gear accuracy increases, and the establishment of a traceability system is needed. Therefore, a high-precision gear measuring machine (GMM) with a smaller uncertainty is expected to improve the gear calibration uncertainty. For this purpose, we developed a prototype of a high-precision GMM that adopts a direct drive mechanism and other features. Then, the high measurement capability of the developed GMM was verified using gear artifacts. Recently, some new measurement methods using simple shapes such as spheres and planes have been proposed as standards. We have verified the tooth profile measurement using a sphere artifact and reported the results that the developed GMM had a high capability in tooth profile measurement. Therefore, we attempted to devise a new evaluation method for helix measurement using a wedge artifact (WA) whose plane was treated as the tooth flank, and the high measurement capability of the developed GMM was verified. The results will provide a part of information to fully assess measurement uncertainty as our future work. This paper describes the evaluation results of the developed GMM for helix measurement using both a helix artifact and the WA, and discusses the effectiveness of the WA as a new artifact to evaluate the GMMs.

  17. High-precision Distribution of Highly-stable Optical Pulse Trains with Sub-10-fs Timing Jitter

    CERN Document Server

    Ning, B; Hou, D; Wu, J T; Li, Z B; Zhao, J Y

    2014-01-01

    High-precision optical pulse trains distribution via fibre links has made huge impacts in many fields. In most published works, the accuracies are still fundamentally limited by some unavoidable noises, such as thermal and shot noise from conventional photodiodes, thermal noise from mixers. Here, we demonstrate a new high-precision timing distribution system by using highly-precision phase detector to overcome the limitations. Instead of using photodiodes and microwave mixers, we use several fibre Sagnac-loop-based optical-microwave phase detectors to realize optical-electrical conversion and phase measurements, for suppressing the noises and achieving ultra-high accuracy. A 10-km fibre link distribution experiment shows our system provides a residual instability at the level of 4.6*10-15@1-s and 6.1*10-18@10000-s, with an integrated timing jitter as low as 3.8 fs in a bandwidth of 1 Hz to 100 KHz. This low instability and timing jitter makes it possible that our system can be used in the optical clock distri...

  18. Systematic study on the performance of elliptic focusing neutron guides

    Energy Technology Data Exchange (ETDEWEB)

    Martin Rodriguez, D., E-mail: damian.rodriguez@esss.se [European Spallation Source ERIC, Box 176, 221 00 Lund (Sweden); DiJulio, D.D. [European Spallation Source ERIC, Box 176, 221 00 Lund (Sweden); Department of Physics, Lund University, SE-221 00 Lund (Sweden); Bentley, P.M. [European Spallation Source ERIC, Box 176, 221 00 Lund (Sweden); Department of Physics and Astronomy, University of Uppsala, Uppsala 751 20 (Sweden)

    2016-02-01

    In neutron scattering experiments there is an increasing trend towards the study of smaller volume samples, which make the use of focusing optics more important. Focusing guide geometries based on conic-sections, such as those with parabolic and elliptic shapes, have been extensively used in both recently built neutron instruments and upgrades of existing hardware. A large fraction of proposed instruments at the European Spallation Source feature the requirement of good performance when measuring on small samples. The optimised design of a focusing system comes after time consuming Monte-Carlo (MC) simulations. Therefore, in order to help reduce the time needed to design such focusing systems, it is necessary to study systematically the performance of focusing guides. In the present work, we perform a theoretical analysis of the focusing properties of neutron beams, and validate them using a combination of Monte-Carlo simulations and Particle Swarm Optimisations (PSOs), where there is a close correspondence between the maximum divergence of the beam and the shape of the guide. The analytical results show that two limits can be considered, which bound a range of conic section shapes that provide optimum performance. Finally, we analyse a more realistic guide example and we give an assessment of the importance of the contribution from multiple reflections in different systems.

  19. A Systematic Spectroscopic Study of Four Apollo Lunar Soils

    Institute of Scientific and Technical Information of China (English)

    Zongcheng Ling; Alian Wang; Bradley L Jolliff

    2011-01-01

    A systematic spectroscopic study including Raman,Mid-IR,NIR,and VIS-NIR,is used to investigate four endmember lunar soils.Apollo soils (<45 μm) 14163,15271,67511,and 71501 were selected as endmembers to study,based on their soil chemistry,maturity against space weathering,and the sampling locations.These endmembers include an anorthositic highlands soil (67511),a low-Ti basaltic soil (15271),a high-Ti basaltic soil (71501),and a mafic,KREEPy,impact-melt-rich soil (14163).We used a laser Raman point-counting procedure to derive mineral modes of the soils and the compositional distributions of major mineral phases,which in turn reflect characteristics of the main source materials for these soils.The Mid-lR,NIR,and VIS-NIR spectroscopic properties also yield distinct information on mineralogy,geochemistry,and maturity among the four soils.Knowledge of the mineralogy resulting from the Raman point-counting procedure corresponds well with bulk mineralogy and soil properties based on Mid-IR,NIR,and VIS-NIR spectroscopy.The future synergistic application of these spectroscopy methods on the Moon will provide a linkage between the results from in situ surface exploration and those from orbital remote- sensing observations.

  20. Changing Phases of Alien Worlds: Probing Atmospheres of Kepler Planets with High-Precision Photometry

    CERN Document Server

    Esteves, Lisa J; Jayawardhana, Ray

    2014-01-01

    We present a comprehensive analysis of planetary phase variations, including possible planetary light offsets, using eighteen quarters of data from the Kepler space telescope. After correcting for systematics, we found fourteen systems with significant detections in each of the phase curve components: planet's phase function, secondary eclipse, Doppler boosting and ellipsoidal variations. We model the full phase curve simultaneously, including primary and secondary transits, and derive albedos, day- and night-side temperatures and planet masses. We find that KOI-13b, with a small eccentricity, is the only planet for which an eccentric orbit is favored. We detect a third harmonic with an amplitude of 1.9 ppm for HAT-P-7b for the first time, and confirm the third harmonic for KOI-13b reported in Esteves et al. (2013): both could be due to their spin-orbit misalignments. We also performed a bootstrap analysis of each of our targets, and conclude that the photometric variations of Kepler-43b are not of planetary ...

  1. Contributions of plant molecular systematics to studies of molecular evolution.

    Science.gov (United States)

    Soltis, E D; Soltis, P S

    2000-01-01

    Dobzhansky stated that nothing in biology makes sense except in the light of evolution. A close corollary, and the central theme of this paper, is that everything makes a lot more sense in the light of phylogeny. Systematics is in the midst of a renaissance, heralded by the widespread application of new analytical approaches and the introduction of molecular techniques. Molecular phylogenetic analyses are now commonplace, and they have provided unparalleled insights into relationships at all levels of plant phylogeny. At deep levels, molecular studies have revealed that charophyte green algae are the closest relatives of the land plants and suggested that liverworts are sister to all other extant land plants. Other studies have suggested that lycopods are sister to all other vascular plants and clarified relationships among the ferns. The impact of molecular phylogenetics on the angiosperms has been particularly dramatic--some of the largest phylogenetic analyses yet conducted have involved the angiosperms. Inferences from three genes (rbcL, atpB, 18S rDNA) agree in the major features of angiosperm phylogeny and have resulted in a reclassification of the angiosperms. This ordinal-level reclassification is perhaps the most dramatic and important change in higher-level angiosperm taxonomy in the past 200 years. At lower taxonomic levels, phylogenetic analyses have revealed the closest relatives of many crops and 'model organisms' for studies of molecular genetics, concomitantly pointing to possible relatives for use in comparative studies and plant breeding. Furthermore, phylogenetic information has contributed to new perspectives on the evolution of polyploid genomes. The phylogenetic trees now available at all levels of the taxonomic hierarchy for angiosperms and other green plants should play a pivotal role in comparative studies in diverse fields from ecology to molecular evolution and comparative genetics.

  2. Systematic study of the pp -> pp omega reaction

    CERN Document Server

    Abdel-Bary, M; Brinkmann, K -Th; Clement, H; Dietrich, J; Doroshkevich, E; Dshemuchadse, S; Ehrhardt, K; Erhardt, A; Eyrich, W; Filippi, A; Freiesleben, H; Fritsch, M; Gast, W; Gillitzer, A; Gottwald, J; Jäger, H; Jakob, B; Jäkel, R; Karsch, L; Kilian, K; Koch, H; Krapp, M; Kreß, J; Kuhlmann, E; Lehmann, A; Marcello, S; Mauro, S; Michel, P; Möller, K; Morsch, H P; Naumann, L; Paul, N; Pizzolotto, C; Plettner, Ch; Reimann, S; Richter, M; Ritman, J; Roderburg, E; Schamlott, A; Schönmeier, P; Schroeder, W; Schulte-Wissermann, M; Sefzick, T; Steinke, M; Sun, G Y; Teufel, A; Ullrich, W; Wagner, G J; Wagner, M; Wenzel, R; Wilms, A; Wintz, P; Wüstner, P; Zupranski, P

    2010-01-01

    A systematic study of the production of omega-mesons in proton-proton-collisions was carried out in a kinematically complete experiment at three excess energies(epsilon= 92, 128, 173MeV). Both protons were detected using the large-acceptance COSY-TOF spectrometer at an external beam line at the Cooler Synchrotron COSY at Forschungszentrum J\\"ulich. The total cross section, angular distributions of both omega-mesons and protons were measured and presented in various reference frames such as the overall CMS, helicity and Jackson frame. In addition, the orientation of the omega-spin and invariant mass spectra were determined. We observe omega-production to take place dominantly in Ss and Sp final states at epsilon = 92, 128 MeV and, additionally, in Sd at epsilon= 173 MeV. No obvious indication of resonant omega-production via N^*-resonances was found, as proton angular distributions are almost isotropic and invariant mass spectra are compatible with phase space distributions. A dominant role of ^3P_1 and ^1S_0 ...

  3. Flettner Rotor Concept for Marine Applications: A Systematic Study

    Directory of Open Access Journals (Sweden)

    A. De Marco

    2016-01-01

    Full Text Available The concept of Flettner rotor, a rotating cylinder immersed in a fluid current, with a top-mounted disk, has been analyzed by means of unsteady Reynolds averaged Navier-Stokes simulations, with the aim of creating a suitable tool for the preliminary design of the Flettner rotor as a ship’s auxiliary propulsion system. The simulation has been executed to evaluate the performance sensitivity of the Flettner rotor with respect to systematic variations of several parameters, that is, the spin ratio, the rotor aspect ratio, the effect of the end plates, and their dimensions. The Flettner rotor device has been characterized in terms of lift and drag coefficients, and these data were compared with experimental trends available in literature. A verification study has been conducted in order to evaluate the accuracy of the simulation results and the main sources of numerical uncertainty. All the simulation results were used to achieve a surrogate model of lift and drag coefficients. This model is an effective mathematical tool for the preliminary design of Flettner rotor. Finally, an example of assessment of the Flettner rotor performance as an auxiliary propulsion device on a real tanker ship is reported.

  4. The Araucaria Project: High-precision orbital parallax and masses of the eclipsing binary TZ Fornacis

    Science.gov (United States)

    Gallenne, A.; Pietrzyński, G.; Graczyk, D.; Konorski, P.; Kervella, P.; Mérand, A.; Gieren, W.; Anderson, R. I.; Villanova, S.

    2016-02-01

    Context. Independent distance estimates are particularly useful to check the precision of other distance indicators, while accurate and precise masses are necessary to constrain evolution models. Aims: The goal is to measure the masses and distance of the detached eclipsing-binary TZ For with a precision level lower than 1% using a fully geometrical and empirical method. Methods: We obtained the first interferometric observations of TZ For with the VLTI/PIONIER combiner, which we combined with new and precise radial velocity measurements to derive its three-dimensional orbit, masses, and distance. Results: The system is well resolved by PIONIER at each observing epoch, which allowed a combined fit with eleven astrometric positions. Our derived values are in a good agreement with previous work, but with an improved precision. We measured the mass of both components to be M1 = 2.057 ± 0.001 M⊙ and M2 = 1.958 ± 0.001 M⊙. The comparison with stellar evolution models gives an age of the system of 1.20 ± 0.10 Gyr. We also derived the distance to the system with a precision level of 1.1%: d = 185.9 ± 1.9 pc. Such precise and accurate geometrical distances to eclipsing binaries provide a unique opportunity to test the absolute calibration of the surface brightness-colour relation for late-type stars, and will also provide the best opportunity to check on the future Gaia measurements for possible systematic errors. Based on observations made with ESO telescopes at Paranal observatory under program IDs 094.D-0320.The calibrated interferometric data as OIFITS files are only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (ftp://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/586/A35

  5. Semi-robotic 6 degree of freedom positioning for intracranial high precision radiotherapy; first phantom and clinical results

    Directory of Open Access Journals (Sweden)

    Flentje Michael

    2010-05-01

    Full Text Available Abstract Background To introduce a novel method of patient positioning for high precision intracranial radiotherapy. Methods An infrared(IR-array, reproducibly attached to the patient via a vacuum-mouthpiece(vMP and connected to the table via a 6 degree-of-freedom(DoF mechanical arm serves as positioning and fixation system. After IR-based manual prepositioning to rough treatment position and fixation of the mechanical arm, a cone-beam CT(CBCT is performed. A robotic 6 DoF treatment couch (HexaPOD™ then automatically corrects all remaining translations and rotations. This absolute position of infrared markers at the first fraction acts as reference for the following fractions where patients are manually prepositioned to within ± 2 mm and ± 2° of this IR reference position prior to final HexaPOD-based correction; consequently CBCT imaging is only required once at the first treatment fraction. The preclinical feasibility and attainable repositioning accuracy of this method was evaluated on a phantom and human volunteers as was the clinical efficacy on 7 pilot study patients. Results Phantom and volunteer manual IR-based prepositioning to within ± 2 mm and ± 2° in 6DoF was possible within a mean(± SD of 90 ± 31 and 56 ± 22 seconds respectively. Mean phantom translational and rotational precision after 6 DoF corrections by the HexaPOD was 0.2 ± 0.2 mm and 0.7 ± 0.8° respectively. For the actual patient collective, the mean 3D vector for inter-treatment repositioning accuracy (n = 102 was 1.6 ± 0.8 mm while intra-fraction movement (n = 110 was 0.6 ± 0.4 mm. Conclusions This novel semi-automatic 6DoF IR-based system has been shown to compare favourably with existing non-invasive intracranial repeat fixation systems with respect to handling, reproducibility and, more importantly, intra-fraction rigidity. Some advantages are full cranial positioning flexibility for single and fractionated IGRT treatments and possibly increased patient

  6. High-precision geologic mapping to evaluate the potential for seismic surface rupture at TA-55, Los Alamos National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Gardner, J.N.; Lavine, A.; Vaniman, D.; WoldeGabriel, G.

    1998-06-01

    In this report the authors document results of high-precision geologic mapping in the vicinity of TA-55 that has been done to identify parts of the southern portion of the Rendija Canyon Fault, or any other faults, with the potential for seismic surface rupture. To assess the potential for surface rupture at TA-55, an area of approximately 3 square miles that includes the Los Alamos County Landfill and Twomile, Mortandad, and Sandia Canyons has been mapped in detail. Map units are mostly cooling or flow units within the Tshirege Member (1.2 Ma) of the Bandelier Tuff. Stratigraphic markers that are useful for determining offsets in the map area include a distinct welding break at or near the cooling Unit 2-Unit 3 contact, and the Unit 3-Unit 4 contact. At the County Landfill the contact between the Tshirege Member of the Bandelier Tuff and overlying Quaternary alluvium has also been mapped. The mapping indicates that there is no faulting in the near-surface directly below TA-55, and that the closest fault is about 1500 feet west of the Plutonium Facility. Faulting is more abundant on the western edge of the map area, west of TA-48 in uppermost Mortandad Canyon, upper Sandia Canyon, and at the County Landfill. Measured vertical offsets on the faults range from 1 to 8 feet on mapped Bandelier Tuff contacts. Faulting exposed at the Los Alamos County Landfill has deformed a zone over 1000 feet wide, and has a net vertical down-to-the-west displacement of at least 15 feet in the Bandelier Tuff. Individual faults at the landfill have from less than 1 foot to greater than 15 feet of vertical offset on the Bandelier Tuff. Most faults in the landfill trend N-S, N20W, or N45E. Results of the mapping indicate that the Rendija Canyon Fault does not continue directly south to TA-55. At present, the authors have insufficient data to connect faulting they have mapped to areas of known faulting to the north or south of the study area.

  7. Parental views on otitis media: systematic review of qualitative studies.

    Science.gov (United States)

    Chando, Shingisai; Young, Christian; Craig, Jonathan C; Gunasekera, Hasantha; Tong, Allison

    2016-10-01

    This study aims to describe parental experiences and perspectives of caring for a child with otitis media. We conducted a systematic review of qualitative studies on parental perspectives on caring for a child with otitis media. We searched electronic databases to July 2015. Seventeen studies involving 284 participants from six countries were included. We identified seven themes: diminishing competency (guilt over failure to identify symptoms, helpless and despairing, fear of complications, disempowered and dismissed); disrupting life schedules (disturbing sleep, interfering with work, burden on family); social isolation (stigma and judgement, sick consciousness); threatening normal development (delaying growth milestones, impairing interpersonal skills, impeding education); taking ownership (recognising symptoms, diagnostic closure, working the system, protecting against physical trauma, contingency planning); valuing support (needing respite, depending on community, clinician validation); and cherishing health (relief with treatment success, inspiring resilience). The additional medical responsibilities and anxieties of parents caring for a child with otitis media, often discounted by clinicians, can be disempowering and disruptive. Chronicity can raise doubt about treatment efficacy and parental competency, and fears regarding their child's development. Care that fosters parental confidence and addresses their concerns about the child's development may improve treatment outcomes for children with otitis media. • Otitis media is a leading cause of conductive hearing loss in children. • Parental perception of the treatment burden of otitis media can potentially affect their confidence and ability to care for their child. What is New: • We identified five themes to reflect parental perspectives: diminishing competency, disrupting life schedules, social isolation, threatening normal development, taking ownership, valuing support, and cherishing health.

  8. Study of Myelin Basic Protein Associated with Pediatric Systematic Epilepsy

    Institute of Scientific and Technical Information of China (English)

    Yang Sida; He Xin; Yang Yiyu; Zhu Huihua; He Dansha; Deng Weiyi

    2000-01-01

    Objective: To investigate the quantitative myelin basic protein (MBP) in cerebrospinal fluid (CSF) and serum in pediatric systematic epilepsy (SEP), study the relation between SEP and MBP, and the possibility predicating'the injury of myelin and blood-brain barrier (BBB) from pediatric SEP. Background: While tactors induced destroy of cerebral and Myelin, MBP was released out into CSF to increase its concentration. On the other hand, the BBB was involved to make serum MBP increased. The related studies had confirmed these viewpoints above. The test for quantitative MBP was recognized as the specific biochemical index, which diagnose if there is or not organic injury of cerebral and myelin. There was few reports about the studies of quantitative MBP in CSF and serum of EP, not mention to those published in domestic pediatric academia. Methods: 47 cases were studied during one month after the SEP attack, whose MBP in serum were quantitatively and 31 inside in CSF were also tested by easy MBP-ELISA method; the quantitative MBP in serum of 30 control cases and 10 in CSF were tested, too. Results: MBP values in CSF and serum of SEP pediatric patients were 2.95±0.61 ng/ml and 3.17±0.53 ng/ml; whereas 1.41 ±0.19 ng/ml and 1.30±0.04 ng/ml in control group. Both mean valves of MBP in CSF and serum in study group were significantly higher than control group (either P< 0.01). Discussion: In general, electrophysiological evidences supported the issue that epileptic episode was originated from abnormal electrical activities of nervous cells. Pathological studies revealed degeneration and necrosis of nerve existed in temporal epileptic focus, where there was morphological change of myelin. This study showed MBP values in CSF and serum of SEEP, during one month after attack, increased significantly; suggested there was changed component of MBP, while SEP could not be controled. Those above indicated the destroy of myelin, increasing of BBB permeability that induced its

  9. Systematic studies of small scintillators for new sampling calorimeter

    Indian Academy of Sciences (India)

    E P Jacosalem; S Iba; N Nakajima; H Ono; A L C Sanchez; A M Bacala; H Miyata; GLD Calorimeter Group

    2007-12-01

    A new sampling calorimeter using very thin scintillators and the multi-pixel photon counter (MPPC) has been proposed to produce better position resolution for the international linear collider (ILC) experiment. As part of this R & D study, small plastic scintillators of different sizes, thickness and wrapping reflectors are systematically studied. The scintillation light due to beta rays from a collimated 90Sr source are collected from the scintillator by wavelength-shifting (WLS) fiber and converted into electrical signals at the PMT. The wrapped scintillator that gives the best light yield is determined by comparing the measured pulse height of each 10 × 40 × 2 mm strip scintillator covered with 3M reflective mirror film, teflon, white paint, black tape, gold, aluminum and white paint+teflon. The pulse height dependence on position, length and thickness of the 3M reflective mirror film and teflon wrapped scintillators are measured. Results show that the 3M radiant mirror film-wrapped scintillator has the greatest light yield with an average of 9.2 photoelectrons. It is observed that light yield slightly increases with scintillator length, but increases to about 100% when WLS fiber diameter is increased from 1.0 mm to 1.6 mm. The position dependence measurement along the strip scintillator showed the uniformity of light transmission from the sensor to the PMT. A dip across the strip is observed which is 40% of the maximum pulse height. The block type scintillator pulse height, on the other hand, is found to be almost proportional to scintillator thickness.

  10. Publication misconduct and plagiarism retractions: a systematic, retrospective study.

    Science.gov (United States)

    Stretton, Serina; Bramich, Narelle J; Keys, Janelle R; Monk, Julie A; Ely, Julie A; Haley, Cassandra; Woolley, Mark J; Woolley, Karen L

    2012-10-01

    To investigate whether plagiarism is more prevalent in publications retracted from the medical literature when first authors are affiliated with lower-income countries versus higher-income countries. Secondary objectives included investigating other factors associated with plagiarism (e.g., national language of the first author's country affiliation, publication type, journal ranking). Systematic, controlled, retrospective, bibliometric study. Retracted publications dataset in MEDLINE (search filters: English, human, January 1966-February 2008). Retracted misconduct publications were classified according to the first author's country affiliation, country income level, and country national language, publication type, and ranking of the publishing journal. Standardised definitions and data collection tools were used; data were analysed (odds ratio [OR], 95% confidence limits [CL], chi-squared tests) by an independent academic statistician. Of the 213 retracted misconduct publications, 41.8% (89/213) were retracted for plagiarism, 52.1% (111/213) for falsification/fabrication, 2.3% (5/213) for author disputes, 2.3% (5/213) for ethical issues, and 1.4% (3/213) for unknown reasons. The OR (95% CL) of plagiarism retractions (other misconduct retractions as reference) were higher (P 1 retraction) with publications retracted for plagiarism (11.5%, 9/78) than other types of misconduct (28.9%, 24/83). This is the first study to demonstrate that publications retracted for plagiarism are significantly associated with first authors affiliated with lower-income countries. These findings have implications for developing appropriate evidence-based strategies and allocation of resources to help mitigate plagiarism misconduct.

  11. CLASH-VLT: A highly precise strong lensing model of the galaxy cluster RXC J2248.7-4431 (Abell S1063) and prospects for cosmography

    Science.gov (United States)

    Caminha, G. B.; Grillo, C.; Rosati, P.; Balestra, I.; Karman, W.; Lombardi, M.; Mercurio, A.; Nonino, M.; Tozzi, P.; Zitrin, A.; Biviano, A.; Girardi, M.; Koekemoer, A. M.; Melchior, P.; Meneghetti, M.; Munari, E.; Suyu, S. H.; Umetsu, K.; Annunziatella, M.; Borgani, S.; Broadhurst, T.; Caputi, K. I.; Coe, D.; Delgado-Correal, C.; Ettori, S.; Fritz, A.; Frye, B.; Gobat, R.; Maier, C.; Monna, A.; Postman, M.; Sartoris, B.; Seitz, S.; Vanzella, E.; Ziegler, B.

    2016-03-01

    Aims: We perform a comprehensive study of the total mass distribution of the galaxy cluster RXC J2248.7-4431 (z = 0.348) with a set of high-precision strong lensing models, which take advantage of extensive spectroscopic information on many multiply lensed systems. In the effort to understand and quantify inherent systematics in parametric strong lensing modelling, we explore a collection of 22 models in which we use different samples of multiple image families, different parametrizations of the mass distribution and cosmological parameters. Methods: As input information for the strong lensing models, we use the Cluster Lensing And Supernova survey with Hubble (CLASH) imaging data and spectroscopic follow-up observations, with the VIsible Multi-Object Spectrograph (VIMOS) and Multi Unit Spectroscopic Explorer (MUSE) on the Very Large Telescope (VLT), to identify and characterize bona fide multiple image families and measure their redshifts down to mF814W ≃ 26. A total of 16 background sources, over the redshift range 1.0-6.1, are multiply lensed into 47 images, 24 of which are spectroscopically confirmed and belong to ten individual sources. These also include a multiply lensed Lyman-α blob at z = 3.118. The cluster total mass distribution and underlying cosmology in the models are optimized by matching the observed positions of the multiple images on the lens plane. Bayesian Markov chain Monte Carlo techniques are used to quantify errors and covariances of the best-fit parameters. Results: We show that with a careful selection of a large sample of spectroscopically confirmed multiple images, the best-fit model can reproduce their observed positions with a rms scatter of 0.̋3 in a fixed flat ΛCDM cosmology, whereas the lack of spectroscopic information or the use of inaccurate photometric redshifts can lead to biases in the values of the model parameters. We find that the best-fit parametrization for the cluster total mass distribution is composed of an

  12. New Progress in High-Precision and High-Resolution Seismic Exploration Technique in Coal Industry of China

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    In the past twenty years, the proportion of coal in primary-energy consumption in China is generally between 71.3% and 76.5%. The output of coal was 1.374 billion tons in 1996, and 1.21 tons in 1998, which ranked first in the world. Now coal is mined mainly with mechanization in China, which is planned to reach 80% in major State-owned coal mines in 2000 according to the planning of the government (Li et al., 1998; Tang Dejin, 1998).Compared with the USA and Australia, China has more complex coal geological structures. Based on high-resolution seismic technique in coal exploration, a new seismic technique with high-precision and high-resolution (2-D and 3-D) has been developed for the purpose of detecting small geological structures in coal mine construction and production to meet the needs of large-scale popularization of mechanized coal mining in China. The technique is low in cost and requires a relatively short period of exploration, with high precision and wide-range applications. In the middle of the 1980s, it began to be used in pre-mining coal exploration on a trial basis, and entered the peak of exploration in the 1990s, which has made significant progress in providing high-precision geological results for the construction and production of coal industry in China, and is still in the ascendant.This paper discusses some new progress and the exploration capability and application range of the technique.

  13. Ayahuasca, dimethyltryptamine, and psychosis: a systematic review of human studies.

    Science.gov (United States)

    Dos Santos, Rafael G; Bouso, José Carlos; Hallak, Jaime E C

    2017-04-01

    Ayahuasca is a hallucinogen brew traditionally used for ritual and therapeutic purposes in Northwestern Amazon. It is rich in the tryptamine hallucinogens dimethyltryptamine (DMT), which acts as a serotonin 5-HT2A agonist. This mechanism of action is similar to other compounds such as lysergic acid diethylamide (LSD) and psilocybin. The controlled use of LSD and psilocybin in experimental settings is associated with a low incidence of psychotic episodes, and population studies corroborate these findings. Both the controlled use of DMT in experimental settings and the use of ayahuasca in experimental and ritual settings are not usually associated with psychotic episodes, but little is known regarding ayahuasca or DMT use outside these controlled contexts. Thus, we performed a systematic review of the published case reports describing psychotic episodes associated with ayahuasca and DMT intake. We found three case series and two case reports describing psychotic episodes associated with ayahuasca intake, and three case reports describing psychotic episodes associated with DMT. Several reports describe subjects with a personal and possibly a family history of psychosis (including schizophrenia, schizophreniform disorders, psychotic mania, psychotic depression), nonpsychotic mania, or concomitant use of other drugs. However, some cases also described psychotic episodes in subjects without these previous characteristics. Overall, the incidence of such episodes appears to be rare in both the ritual and the recreational/noncontrolled settings. Performance of a psychiatric screening before administration of these drugs, and other hallucinogens, in controlled settings seems to significantly reduce the possibility of adverse reactions with psychotic symptomatology. Individuals with a personal or family history of any psychotic illness or nonpsychotic mania should avoid hallucinogen intake.

  14. Systematic study of the pp {yields}pp{omega} reaction

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Bary, M.; Abdel-Samad, S.; Gast, W.; Gillitzer, A.; Jaeger, H.; Kilian, K.; Paul, N.; Ritman, J.; Roderburg, E.; Sefzick, T.; Wintz, P.; Wuestner, P. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Brinkmann, K.T.; Dietrich, J.; Dshemuchadse, S.; Freiesleben, H.; Gottwald, J.; Jakob, B.; Jaekel, R.; Karsch, L.; Kuhlmann, E.; Plettner, C.; Reimann, S.; Richter, M.; Schoenmeier, P.; Schulte-Wissermann, M.; Sun, G.Y.; Ullrich, W.; Wenzel, R. [Technische Universitaet Dresden, Institut fuer Kern- und Teilchenphysik, Dresden (Germany); Clement, H.; Doroshkevich, E.; Ehrhardt, K.; Erhardt, A.; Kress, J.; Wagner, G.J. [Universitaet Tuebingen, Physikalisches Institut, Tuebingen (Germany); Eyrich, W.; Fritsch, M.; Krapp, M.; Lehmann, A.; Pizzolotto, C.; Schroeder, W.; Teufel, A.; Wagner, M. [Universitaet Erlangen-Nuernberg, Physikalisches Institut, Erlangen (Germany); Filippi, A.; Marcello, S. [INFN Torino, Torino (Italy); Koch, H.; Mauro, S.; Steinke, M.; Wilms, A. [Ruhr-Universitaet Bochum, Institut fuer Experimentalphysik, Bochum (Germany); Michel, P.; Moller, K.; Naumann, L.; Schamlott, A. [Forschungszentrum Dresden-Rossendorf, Institut fuer Kern- und Hadronenphysik, Dresden (Germany); Morsch, H.P. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Soltan Institute for Nuclear Studies, Swierk/Otwock (Poland)

    2010-04-15

    A systematic study of the production of {omega}-mesons in proton-proton collisions was carried out in a kinematically complete experiment at three excess energies ({epsilon}=92, 128, 173 MeV). Both protons were detected using the large-acceptance COSY-TOF spectrometer at an external beam line at the Cooler Synchrotron COSY at Forschungszentrum Juelich. The total cross-section, angular distributions of both {omega}-mesons and protons were measured and presented in various reference frames such as the overall CMS, helicity and Jackson frame. In addition, the orientation of the {omega}-spin and invariant-mass spectra were determined. We observe {omega}-production to take place dominantly in Ss and Sp final states at {epsilon}=92, 128 MeV and, additionally, in Sd at {epsilon}=173 MeV. No obvious indication of resonant {omega}-production via N{sup *}-resonances was found, as proton angular distributions are almost isotropic and invariant-mass spectra are compatible with phase space distributions. A dominant role of {sup 3}P{sub 1} and {sup 1}S{sub 0} initial partial waves for {omega}-production was concluded from the orientation of the decay plane of the {omega}-meson. Although the Jackson angle distributions in the {omega} p-Jackson frame are anisotropic we argue that this is not an indication of a resonance but rather a kinematical effect reflecting the anisotropy of the {omega} angular distribution. The helicity angle distribution in the {omega} p-helicity frame shows an anisotropy which probably reflects effects of the {omega} angular momenta in the final state; this observable may be, in addition to the orientation of the {omega} decay plane, the most sensitive one to judge the validity of theoretical descriptions of the production process. (orig.)

  15. Systematic study of the pp rightarrow pp ω reaction

    Science.gov (United States)

    Abdel-Bary, M.; Abdel-Samad, S.; Brinkmann, K.-Th.; Clement, H.; Dietrich, J.; Doroshkevich, E.; Dshemuchadse, S.; Ehrhardt, K.; Erhardt, A.; Eyrich, W.; Filippi, A.; Freiesleben, H.; Fritsch, M.; Gast, W.; Gillitzer, A.; Gottwald, J.; Jäger, H.; Jakob, B.; Jäkel, R.; Karsch, L.; Kilian, K.; Koch, H.; Krapp, M.; Kreß, J.; Kuhlmann, E.; Lehmann, A.; Marcello, S.; Mauro, S.; Michel, P.; Móller, K.; Morsch, H. P.; Naumann, L.; Paul, N.; Pizzolotto, C.; Plettner, Ch.; Reimann, S.; Richter, M.; Ritman, J.; Roderburg, E.; Schamlott, A.; Schönmeier, P.; Schroeder, W.; Schulte-Wissermann, M.; Sefzick, T.; Steinke, M.; Sun, G. Y.; Teufel, A.; Ullrich, W.; Wagner, G. J.; Wagner, M.; Wenzel, R.; Wilms, A.; Wintz, P.; Wüstner, P.; Zupranski, P.; COSY-TOF Collaboration

    2010-04-01

    A systematic study of the production of ω -mesons in proton-proton collisions was carried out in a kinematically complete experiment at three excess energies ( \\varepsilon = 92, 128, 173 MeV). Both protons were detected using the large-acceptance COSY-TOF spectrometer at an external beam line at the Cooler Synchrotron COSY at Forschungszentrum Jülich. The total cross-section, angular distributions of both ω -mesons and protons were measured and presented in various reference frames such as the overall CMS, helicity and Jackson frame. In addition, the orientation of the ω -spin and invariant-mass spectra were determined. We observe ω -production to take place dominantly in Ss and Sp final states at \\varepsilon = 92, 128 MeV and, additionally, in Sd at \\varepsilon = 173 MeV. No obvious indication of resonant ω -production via N*-resonances was found, as proton angular distributions are almost isotropic and invariant-mass spectra are compatible with phase space distributions. A dominant role of 3 P 1 and 1 S 0 initial partial waves for ω -production was concluded from the orientation of the decay plane of the ω -meson. Although the Jackson angle distributions in the ω p-Jackson frame are anisotropic we argue that this is not an indication of a resonance but rather a kinematical effect reflecting the anisotropy of the ω angular distribution. The helicity angle distribution in the ω p-helicity frame shows an anisotropy which probably reflects effects of the ω angular momenta in the final state; this observable may be, in addition to the orientation of the ω decay plane, the most sensitive one to judge the validity of theoretical descriptions of the production process.

  16. Response Rates in Studies of Couples Coping With Cancer : A Systematic Review

    NARCIS (Netherlands)

    Dagan, Meirav; Hagedoorn, Mariet

    2014-01-01

    Objective: Recruiting couples for psychological studies can be challenging. This brief report is the first to examine the average couples' response rate and to systematically review the quality of reporting of couples' response rate in studies of couples coping with cancer. Method: A systematic revi

  17. Permanent catheters for recurrent ascites-a critical and systematic review of study methodology

    DEFF Research Database (Denmark)

    Christensen, Lars; Wildgaard, Lorna Elizabeth; Wildgaard, Kim

    2016-01-01

    was to systematically asses the methodology of factors and endpoints reported in studies investigating permanent catheters for recurrent ascites treatment. Methods Using a systematic search strategy, we critically assessed the methodology when treating refractory ascites using a permanent catheter. Studies critically...

  18. The Transiting System GJ1214: High-Precision Defocused Transit Observations and a Search for Evidence of Transit Timing Variation

    DEFF Research Database (Denmark)

    Harpsøe, Kennet Bomann West; Hardis, S.; Hinse, T. C.;

    2012-01-01

    Aims: We present 11 high-precision photometric transit observations of the transiting super-Earth planet GJ1214b. Combining these data with observations from other authors, we investigate the ephemeris for possible signs of transit timing variations (TTVs) using a Bayesian approach. Methods......: The observations are used to determine the photometric parameters and the physical properties of the GJ1214 system. Our results are in good agreement with published values. Individual times of mid-transit are measured with uncertainties as low as 10s, allowing us to reduce the uncertainty in the orbital period...

  19. High-precision half-life and branching-ratio measurements for superallowed Fermi β+ emitters at TRIUMF – ISAC

    Directory of Open Access Journals (Sweden)

    Laffoley A. T.

    2014-03-01

    Full Text Available A program of high-precision half-life and branching-ratio measurements for superallowed Fermi β emitters is being carried out at TRIUMF’s Isotope Separator and Accelerator (ISAC radioactive ion beam facility. Recent half-life measurements for the superallowed decays of 14O, 18Ne, and 26Alm, as well as branching-ratio measurements for 26Alm and 74Rb are reported. These results provide demanding tests of the Standard Model and the theoretical isospin symmetry breaking (ISB corrections in superallowed Fermi β decays.

  20. Characterization of an INVS Model IV Neutron Counter for High Precision ($\\gamma,n$) Cross-Section Measurements

    CERN Document Server

    Arnold, C W; Karwowski, H J; Rich, G C; Tompkins, J R; Howell, C R

    2010-01-01

    A neutron counter designed for assay of radioactive materials has been adapted for beam experiments at TUNL. The cylindrical geometry and 64% maximum efficiency make it well suited for ($\\gamma,n$) cross-section measurements near the neutron emission threshold. A high precision characterization of the counter has been made using neutrons from several sources. Using a combination of measurements and simulations, the absolute detection efficiency of the neutron counter was determined to an accuracy of $\\pm$ 3% in the neutron energy range between 0.1 and 1 MeV. It is shown that this efficiency characterization is generally valid for a wide range of targets.