WorldWideScience

Sample records for high-performance liquid chromatography-inductively

  1. Determination of multiple human arsenic metabolites employing high performance liquid chromatography inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Stice, Szabina; Liu, Guangliang; Matulis, Shannon; Boise, Lawrence H.; Cai, Yong

    2016-01-01

    During the metabolism of different arsenic-containing compounds in human, a variety of metabolites are produced with significantly varying toxicities. Currently available analytical methods can only detect a limited number of human metabolites in biological samples during one run due to their diverse characteristics. In addition, co-elution of species is often unnoticeable with most detection techniques leading to inaccurate metabolic profiles and assessment of toxicity. A high performance liquid chromatography inductively coupled mass spectrometry (HPLC-ICP-MS) method was developed that can identify thirteen common arsenic metabolites possibly present in human with special attention dedicated to thiolated or thiol conjugated arsenicals. The thirteen species included in this study are arsenite (AsIII), arsino-glutathione (As(GS)3), arsenate (AsV), monomethylarsonous acid (MMAIII), monomethylarsino-glutathione (MMAIII(GS)2), monomethylarsonic acid (MMAV), dimethylarsinous acid (DMAIII (from DMAIIII)), S-(dimethylarsinic)cysteine (DMAIII(Cys)), dimethylarsino-glutathione (DMAIII(GS)), dimethylarsinic acid (DMAV), dimethylmonothioarsinic acid (DMMTAV), dimethyldithioarsinic acid (DMDTAV), dimethylarsinothioyl glutathione (DMMTAV(GS)). The developed method was applied for the analysis of cancer cells that were incubated with Darinaparsin (DMAIII(GS)), a novel chemotherapeutic agent for refractory malignancies, and the arsenic metabolic profile obtained was compared to results using a previously developed method. This method provides a useful analytical tool which is much needed in unequivocally identifying the arsenicals formed during the metabolism of environmental arsenic exposure or therapeutic arsenic administration. PMID:26708625

  2. Comparative oxidation state specific analysis of arsenic species by high-performance liquid chromatography-inductively coupled-mass spectrometry and hydride generation-cryotrapping-atomic absorption spectrometry

    Science.gov (United States)

    The formation of methylarsonous acid (MAsIII) and dimethylarsinous acid (DMAsIII) in the course of inorganic arsenic (iAs) metabolism plays an important role in the adverse effects of chronic exposure to iAs. High-performance liquid chromatography-inductively coupled plasma-mass ...

  3. Speciation of mercury in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Jia, Xiaoyu; Han, Yi; Liu, Xinli; Duan, Taicheng; Chen, Hangting

    2011-01-01

    The dispersive liquid-liquid microextraction (DLLME) combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry for the speciation of mercury in water samples was described. Firstly methylmercury (MeHg +) and mercury (Hg 2+) were complexed with sodium diethyldithiocarbamate, and then the complexes were extracted into carbon tetrachloride by using DLLME. Under the optimized conditions, the enrichment factors of 138 and 350 for MeHg + and Hg 2+ were obtained from only 5.00 mL sample solution. The detection limits of the analytes (as Hg) were 0.0076 ng mL -1 for MeHg + and 0.0014 ng mL -1 for Hg 2+, respectively. The relative standard deviations for ten replicate measurements of 0.5 ng mL -1 MeHg + and Hg 2+ were 6.9% and 4.4%, respectively. Standard reference material of seawater (GBW(E)080042) was analyzed to verify the accuracy of the method and the results were in good agreement with the certified values. Finally, the developed method was successfully applied for the speciation of mercury in three environmental water samples.

  4. Speciation of mercury in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Jia Xiaoyu; Han Yi; Liu Xinli [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Science, Changchun 130022 (China); Graduate School of Chinese Academy of Sciences, Beijing 100039 (China); Duan Taicheng, E-mail: tcduan@ciac.jl.cn [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Science, Changchun 130022 (China); Chen Hangting, E-mail: htchen@ciac.jl.cn [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Science, Changchun 130022 (China)

    2011-01-15

    The dispersive liquid-liquid microextraction (DLLME) combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry for the speciation of mercury in water samples was described. Firstly methylmercury (MeHg{sup +}) and mercury (Hg{sup 2+}) were complexed with sodium diethyldithiocarbamate, and then the complexes were extracted into carbon tetrachloride by using DLLME. Under the optimized conditions, the enrichment factors of 138 and 350 for MeHg{sup +} and Hg{sup 2+} were obtained from only 5.00 mL sample solution. The detection limits of the analytes (as Hg) were 0.0076 ng mL{sup -1} for MeHg{sup +} and 0.0014 ng mL{sup -1} for Hg{sup 2+}, respectively. The relative standard deviations for ten replicate measurements of 0.5 ng mL{sup -1} MeHg{sup +} and Hg{sup 2+} were 6.9% and 4.4%, respectively. Standard reference material of seawater (GBW(E)080042) was analyzed to verify the accuracy of the method and the results were in good agreement with the certified values. Finally, the developed method was successfully applied for the speciation of mercury in three environmental water samples.

  5. Survey of inorganic arsenic in marine animals and marine certified reference materials by anion exchange high-performance liquid chromatography-inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Sloth, Jens Jørgen; Larsen, Erik Huusfeldt; Julshamn, Kåre

    2005-01-01

    A method for the determination of inorganic arsenic in seafood samples using high-performance liquid chromatography-inductively coupled plasma mass spectrometry is described. The principle of the method relied on microwave-assisted alkaline dissolution of the sample, which at the same time oxidized...... arsenite [As(Ill)] to arsenate [As(V)], whereby inorganic arsenic could be determined as the single species As(V). Anion exchange chromatography using isocratic elution with aqueous ammonium carbonate as the mobile phase was used for the separation of As(V) from other coextracted organoarsenic compounds......, including arsenobetaine. The stability of organoarsenic compounds during the sample pretreatment was investigated, and no degradation/conversion to inorganic arsenic was detected. The method was employed for the determination of inorganic arsenic in a variety of seafood samples including fish, crustaceans...

  6. A rapid monitoring method for inorganic arsenic in rice flour using reversed phase-high performance liquid chromatography-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Narukawa, Tomohiro; Chiba, Koichi; Sinaviwat, Savarin; Feldmann, Jörg

    2017-01-06

    A new rapid monitoring method by means of high performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) following the heat-assisted extraction was developed for measurement of total inorganic arsenic species in rice flour. As(III) and As(V) eluted at the same retention time and completely separated from organoarsenic species by an isocratic elution program on a reversed phase column. Therefore, neither ambiguous oxidation of arsenite to arsenate nor the integration of two peaks were necessary to determine directly the target analyte inorganic arsenic. Rapid injection allowed measuring 3 replicates within 6min and this combined with a quantitative extraction of all arsenic species from rice flour by a 15min HNO3-H2O2 extraction makes this the fastest laboratory based method for inorganic arsenic in rice flour.

  7. Determination of trace mercury species by high performance liquid chromatography-inductively coupled plasma mass spectrometry after cloud point extraction.

    Science.gov (United States)

    Chen, Haiting; Chen, Jianguo; Jin, Xianzhong; Wei, Danyi

    2009-12-30

    A sensitive method for speciation analysis of inorganic mercury (Hg(2+)) and methyl mercury (MeHg(+)) has been developed by using high performance liquid chromatography (HPLC) combined with inductively coupled plasma mass spectrometry (ICP-MS) after cloud point extraction. The analytes were complexed with sodium diethyldithiocarbamate (DDTC) and preconcentrated by a non-ionic surfactant Triton X-114. Mercury species were effectively separated by HPLC in less than 6 min. The enhancement factors for 25 mL sample solution were 42 and 21, and the limits of detection were 4 and 10 ng L(-1) for Hg(2+) and MeHg(+), respectively. The developed method was successfully applied to the determination of trace amount of mercury species in environmental and biological samples.

  8. Speciation of vanadium in oilsand coke and bacterial culture by high performance liquid chromatography inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Li, X. Sherry [Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Le, X. Chris [Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, Alberta T6G 2G3 (Canada)], E-mail: xc.le@ualberta.ca

    2007-10-17

    A simple and sensitive method for the speciation of vanadium(III), (IV), and (V) was developed by using high performance liquid chromatography and inductively coupled plasma mass spectrometry (HPLC-ICPMS). The EDTA-complexed vanadium species were separated on a strong anion exchange column with an eluent containing 2 mM EDTA, 3% acetonitrile, and 80 mM ammonium bicarbonate at pH 6. Each analysis was complete in 5 min. The detection limits were 0.6, 0.7 and 1.0 {mu}g L{sup -1} for V(III), V(IV), and V(V), respectively. The method was applied to coke pore water samples from an oilsand processing/upgrading site in Fort McMurray, Alberta, Canada and to Shewanella putrefaciens CN32 bacterial cultures incubated with V(V). In the coke pore water samples, V(IV) and V(V) were found to be the major species. For the first time, V(III) was detected in the bacterial cultures incubated with V(V)

  9. Fingerprinting of complex mixtures with the use of high performance liquid chromatography, inductively coupled plasma atomic emission spectroscopy and chemometrics

    Energy Technology Data Exchange (ETDEWEB)

    Ni Yongnian [Department of Chemistry, Nanchang University, Nanchang, Jiangxi 330047 (China)], E-mail: ynni@ncu.edu.cn; Peng Yunyan [Department of Chemistry, Nanchang University, Nanchang, Jiangxi 330047 (China); Kokot, Serge [Inorganic Materials Program, School of Physical and Chemical Sciences, Queensland University of Technology, Brisbane, Queensland 4001 (Australia)

    2008-05-26

    The molecular and metal profile fingerprints were obtained from a complex substance, Atractylis chinensis DC-a traditional Chinese medicine (TCM), with the use of the high performance liquid chromatography (HPLC) and inductively coupled plasma atomic emission spectroscopy (ICP-AES) techniques. This substance was used in this work as an example of a complex biological material, which has found application as a TCM. Such TCM samples are traditionally processed by the Bran, Cut, Fried and Swill methods, and were collected from five provinces in China. The data matrices obtained from the two types of analysis produced two principal component biplots, which showed that the HPLC fingerprint data were discriminated on the basis of the methods for processing the raw TCM, while the metal analysis grouped according to the geographical origin. When the two data matrices were combined into a one two-way matrix, the resulting biplot showed a clear separation on the basis of the HPLC fingerprints. Importantly, within each different grouping the objects separated according to their geographical origin, and they ranked approximately in the same order in each group. This result suggested that by using such an approach, it is possible to derive improved characterisation of the complex TCM materials on the basis of the two kinds of analytical data. In addition, two supervised pattern recognition methods, K-nearest neighbors (KNNs) method, and linear discriminant analysis (LDA), were successfully applied to the individual data matrices-thus, supporting the PCA approach.

  10. Arsenic Species in Edible Seaweeds Using In Vitro Biomimetic Digestion Determined by High-Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Yan-Fang Zhao

    2014-01-01

    Full Text Available Arsenite [As (III], arsenate [As (V], methylarsonate (MMA, and dimethylarsinate (DMA in five edible seaweeds (the brown algae Laminaria japonica, red algae Porphyra yezoensis, brown algae Undaria pinnatifida, brown algae Hizikia fusiformis, and green algae Enteromorpha prolifera were analyzed using in vitro digestion method determined by high-performance liquid chromatography inductively coupled plasma mass spectrometry. The results showed that DMA was found in the water extracts of all samples; As (III were detected in L. japonica and U. pinnatifida and about 23.0 and 0.15 mg/kg of As (V were found in H. fusiformis and E. prolifera respectively. However, after the gastrointestinal digestion, As (V was not detected in any of the five seaweeds. About 0.19 and 1.47 mg/kg of As (III was detected in the gastric extracts of L. japonica and H. fusiformis, respectively, and about 0.31 and 0.10 mg/kg of As (III were extracted from the intestinal extracts of Porphyra yezoensis and U. pinnatifida, respectively. The present results successfully reveal the differences of As species and levels in the water and biomimetic extracts of five edible seaweeds. The risk assessment of the inorganic arsenic in the five edible seaweeds based on present data showed almost no hazards to human health.

  11. Speciation of Selenium in Selenium-Enriched Sunflower Oil by High-Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry/Electrospray-Orbitrap Tandem Mass Spectrometry.

    Science.gov (United States)

    Bierla, Katarzyna; Flis-Borsuk, Anna; Suchocki, Piotr; Szpunar, Joanna; Lobinski, Ryszard

    2016-06-22

    The reaction of sunflower oil with selenite produces a complex mixture of selenitriglycerides with antioxidant and anticancer properties. To obtain insight into the identity and characteristics of the species formed, an analytical approach based on the combination of high-performance liquid chromatography (HPLC) with (78)Se-specific selenium detection by inductively coupled plasma mass spectrometry (ICP MS) and high-resolution (100 000), high mass accuracy (sunflower oil dissolved in isopropanol and methanol extract of the oil containing 65% selenium. HPLC-ICP MS showed 14 peaks, 11 of which could also be detected in the methanol extract. Isotopic patterns corresponding to molecules with one or two selenium atoms could be attributed by Orbitrap MS at the retention times corresponding to the HPLC-ICP MS peak apexes. Structural data for these species were acquired by MS(2) and MS(3) fragmentation of protonated or sodiated ions using high-energy collisional dissociation (HCD). A total of 11 selenium-containing triglycerol derivatives resulting from the oxidation of one or two double bonds of linoleic acid and analogous derivatives of glycerol-mixed linoleate(s)/oleinate(s) have been identified for the first time. The presence of these species was confirmed by the targeted analysis in the total oil isopropanol solution. Their identification corroborated the predicted elution order in reversed-phase chromatography: LLL (glycerol trilinoleate), LLO (glycerol dilinoleate-oleinate), LOO (glycerol linoleate-dioleinate), OOO (glycerol trioleinate), of which the extrapolation allowed for the prediction of the identity [glycerol dioleinate-stearate (OOS) and glycerol oleinate-distearate (OSS)] of the nonpolar species detected by ICP MS in the oil but not detected by electrospray MS.

  12. Quantitative Metabolite Profiling of an Amino Group Containing Pharmaceutical in Human Plasma via Precolumn Derivatization and High-Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry.

    Science.gov (United States)

    Li, Sanwang; Klencsár, Balázs; Balcaen, Lieve; Cuyckens, Filip; Lynen, Frederic; Vanhaecke, Frank

    2017-02-07

    Quantitative determination of the candidate drug molecule and its metabolites in biofluids and tissues is an inevitable step in the development of new pharmaceuticals. Because of the time-consuming and expensive nature of the current standard technique for quantitative metabolite profiling, i.e., radiolabeling followed by high-performance liquid chromatography (HPLC) with radiodetection, the development of alternative methodologies is of great interest. In this work, a simple, fast, sensitive, and accurate method for the quantitative metabolite profiling of an amino group containing drug (levothyroxine) and its metabolites in human plasma, based on precolumn derivatization followed by HPLC-inductively coupled plasma mass spectrometry (ICPMS), was developed and validated. To introduce a suitable "heteroelement" (defined here as an element that is detectable with ICPMS), an inexpensive and commercially available reagent, tetrabromophthalic anhydride (TBPA) was used for the derivatization of free NH2-groups. The presence of a known number of I atoms in both the drug molecule and its metabolites enabled a cross-validation of the newly developed derivatization procedure and quantification based on monitoring of the introduced Br. The formation of the derivatives was quantitative, providing a 4:1 stoichiometric Br/NH2 ratio. The derivatives were separated via reversed-phase HPLC with gradient elution. Bromine was determined via ICPMS at a mass-to-charge ratio of 79 using H2 as a reaction gas to ensure interference-free detection, and iodine was determined at a mass-to-charge ratio of 127 for cross-validation purposes. The method developed shows a fit-for-purpose accuracy (recovery between 85% and 115%) and precision (repeatability <15% RSD). The limit of quantification (LoQ) for Br was approximately 100 μg/L.

  13. Simultaneous pressurized enzymatic hydrolysis extraction and clean up for arsenic speciation in seafood samples before high performance liquid chromatography-inductively coupled plasma-mass spectrometry determination.

    Science.gov (United States)

    Moreda-Piñeiro, Jorge; Alonso-Rodríguez, Elia; Moreda-Piñeiro, Antonio; Moscoso-Pérez, Carmen; Muniategui-Lorenzo, Soledad; López-Mahía, Purificación; Prada-Rodríguez, Darío; Bermejo-Barrera, Pilar

    2010-10-29

    The feasibility of pressurized conditions to assist enzymatic hydrolysis of seafood tissues for arsenic speciation was novelty studied. A simultaneous in situ (in cell) clean-up procedure was also optimized, which speeds up the whole sample treatment. Arsenic species (As(III), MMA, DMA, As(V), AsB and AsC) were released from dried seafood tissues using pepsin as a protease, and the arsenic species were separated/quantified by anion exchange high performance liquid chromatography (HPLC) coupled to inductively coupled plasma-mass spectrometry (ICP-MS). Variables inherent to the enzymatic activity (pH, temperature and ionic strength), the amount of enzyme (pepsin), and factors affecting pressurization (pressure, static time, number of cycles and amount of dispersing agent, C-18) were fully evaluated. Pressurized assisted enzymatic hydrolysis (PAEH) with pepsin can be finished after few minutes (two cycles of 2 min each one plus 3 min to reach the hydrolysis temperature of 50 °C). A total sample solubilisation is not achieved after the procedure, however it is efficient enough for breaking down certain bonds of bio-molecules and for releasing arsenic species. The developed method has been found to be precise (RSDs lower than 6% for As(III), DMA and As(V); and 3% for AsB) and sensitive (LOQs of 18.1, 36.2, 35.7, 28.6, 20.6 and 22.5 ng/g for As(III), MMA, DMA, As(V), AsB and AsC, respectively). The optimized methodology was successfully applied to different certified reference materials (DORM-2 and BCR 627) which offer certified AsB and DMA contents, and also to different seafood products (mollusks, white fishes and cold water fishes).

  14. Determination of 20 trace elements and arsenic species for a realgar-containing traditional Chinese medicine Niuhuang Jiedu tablets by direct inductively coupled plasma-mass spectrometry and high performance liquid chromatography-inductively coupled plasma-mass spectrometry.

    Science.gov (United States)

    Jin, Pengfei; Liang, Xiaoli; Xia, Lufeng; Jahouh, Farid; Wang, Rong; Kuang, Yongmei; Hu, Xin

    2016-01-01

    Niuhuang Jiedu tablet (NHJDT) is a realgar-containing traditional Chinese medicine. A direct inductively coupled plasma-mass spectrometry (ICP-MS) method for the simultaneous determination of 20 trace elements (Mg, K, Ca, Na, Fe, As, Zn, Sr, Ba, Cu, Mn, Ni, Pb, V, Cr, Se, Co, Mo, Cd, Hg) in NHJDT, as well as in water, gastric fluid and intestinal fluid was established. Meanwhile, a high performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS) method was developed for the determination of arsenite (As(III)), arsenate (As(V)), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA) and for the identification of arsenobetaine (AsB) and arsenocholine (AsC) in these extracts. Both methods were fully validated in the respect of linearity, sensitivity, precision, stability and accuracy. The reliability of the ICP-MS method was further evaluated using a certified standard reference material prepared from dried tomato leaves (NIST, SRM 1572a). The analysis showed that some manufacturers formulated lower amount of realgar than required in the Chinese Pharmacopoeia (ChP) in their preparations. In addition, almost same extraction profiles for total As and inorganic As were found in water and in gastrointestinal fluids, while higher extraction rates for other 19 elements were observed in gastrointestinal fluids. Our findings show that the toxicities of Hg, Cu, Cd and Pb in NHJDP are low, while the real As toxicity in NHJDT should be deeply investigated.

  15. Selenium speciation in radix puerariae using ultrasonic assisted extraction combined with reversed phase high performance liquid chromatography-inductively coupled plasma-mass spectrometry after magnetic solid-phase extraction with 5-sulfosalicylic acid functionalized magnetic nanoparticles

    Science.gov (United States)

    Cao, Yupin; Yan, Lizhen; Huang, Hongli; Deng, Biyang

    2016-08-01

    A new method for determination of selenium species in radix puerariae was described. The method consists of sample enrichment with 5-sulfosalicylic acid (SSA)-functionalized silica-coated magnetic nanoparticles (SMNPs), high performance liquid chromatography (HPLC) separation, and online detection using inductively coupled plasma mass spectrometry (ICP-MS). The selenium species were extracted using ultrasonic extraction system with a mixture of protease K and lipase. The SSA-SMNPs were used to enrich trace amounts of selenite [Se(IV)], selenate [Se(VI)], selenomethionine (SeMet), and selenocystine (SeCys2) from lower selenium containing samples. Under the optimal conditions, the limits of detection (3σ) for SeCys2, Se(IV), SeMet and Se(VI) were observed as 0.0023, 0.0015, 0.0043, and 0.0016 ng mL- 1, respectively. The RSD values (n = 6) of method for intraday were observed between 0.5% and 0.9%. The RSD values of method for interday were less than 1.3%. The linear concentration ranges for SeCys2, Se(IV), SeMet and Se(VI) were 0.008-1000, 0.005-200, 0.015-500 and 0.006-200 ng mL- 1, respectively. The detection limits of this method were improved by 10 times due to the enrichment with the SSA-SMNP extraction. The contents of SeCys2, Se(IV), SeMet, and Se(VI) in radix puerariae were determined as 0.0140, 0.171, 0.0178, and 0.0344 μg g- 1, respectively. The recoveries were in the range of 95.6%-99.4% and the RSDs (n = 6) of recoveries were less than 1.5%.

  16. 高效液相色谱-电感耦合等离子体质谱同时分析鸡肉中洛克沙生、阿散酸和硝苯胂酸%Simultaneous Determination of Roxarsone,Arsanilic and Nitarsone in Chicken by High Performance Liquid Chromatography/Inductively Coupled Plasma Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    杨丽君; 刘玉敏; 崔凤杰; 郭伟; 徐成钢; 李兆杰

    2011-01-01

    An analytical method was developed to simultaneously determine roxarsone,arsanilic and nitarsone in chicken by high performance liquid chromatography/inductively coupled plasma mass spectrometry(HPLC-ICP-MS).Samples were extracted with methanol/water solution.The chromatographic separation was performed on a Phenomenex Luna C18 using methanol and water(containing 0.05% trifluoroacetic acid) as the mobile phase.Identification and quantification were achieved by using ICP-MS.Good linearity was observed in the range of 1 to 50 μg/kg with correlation coefficients above 0.99.The method was validated at the spike levels of 1,2,10 μg/kg.The validation results indicated that the average recoveries of arsenicum praeparatum ranged from 85.4% to 103.1% with a relative standard deviation of 3.3%-7.2%.The quantification limits of 3 arsenicum praeparatum were 1μg/kg.The method had good reproducibility,high sensitivity and simple pre-treatment.Its performance could meet both domestic and international legislation requirements.This method is applicable for simultaneous determination of arsenicum praeparatum in chicken.%建立一种同时测定鸡肉中洛克沙生、阿散酸和硝苯胂酸等3种有机砷类制剂的高效液相色谱-电感耦合等离子体质谱(high performance liquid chromatography tandem inductively coupled plasma mass spectrometry,HPLC-ICP-MS)分析方法。样品经甲醇溶液提取,采用Phenomenex Luna C18色谱柱,体积分数0.05%的三氟乙酸溶液-甲醇作为流动相进行洗脱,经高效液相色谱分离,电感耦合等离子体质谱进行定性和定量分析。结果表明:1~50μg/kg范围内各砷制剂线性良好,相关系数r2均在0.99以上;在1、2、10μg/kg三个加标水平下进行方法验证,平均回收率为85.4%~103.1%,相对标准偏差为3.3%~7.2%;3种有机砷类制剂的定量限均为1μg/kg。方法重现性好、灵敏度高、前处理简单,各项指标均满足国内外法规要求,适用

  17. Speciation analysis of cadmium in laver by size exclusion chromatography-high performance liquid chromatography-inductively,coupled plasma mass spectrometry%体积排阻高效液相色谱—电感耦合等离子体质谱法测定紫菜中镉(Cd)的形态

    Institute of Scientific and Technical Information of China (English)

    赵艳芳; 尚德荣; 宁劲松; 翟毓秀; 盛晓风; 张明

    2012-01-01

    运用体积排阻高效液相色谱—电感耦合等离子体质谱联用技术( SEC-HPLC-ICP-MS)分析了紫菜中Cd的存在形态,结果发现,在紫菜水提取液中检测到3种Cd形态,根据其保留时间确定为植物螯合肽( PC)3-Cd、谷胱甘肽(GSH)-Cd和1种未知小分子有机态Cd,结合体外全仿生消化技术,研究了在唾液、胃、肠无机物和有机物(含消化酶)作用下,紫菜中Cd的主要存在形态,分析发现在紫菜胃全仿生提取液中,检测到2种未知小分子有机态Cd,其中以保留时间为24.2 min的Cd形态为主要存在形态.在肠全仿生提取液中检测到2种Cd形态,其中(PC)3-Cd是主要存在形态.有关(PC) 3-Cd在生物体内的代谢规律还需进一步研究.实验确证了Cd在紫菜中的主要有机形态,为紫菜食用安全风险评价提供重要依据.%High content of cadmium in laver has seriously affected the edible safety, export and industry development of seaweed in our country. However, only total cadmium content was detected by present method used worldwide and the total cadmium was used to evaluate the food safety of the laver which may over-estimate the toxicity of the cadmium in laver. Because there are different cadmium forms in laver which have different biological toxicities,the speciation analysis of cadmium in the laver is very urgent. However, studies on the cadmium speciation analysis in seaweed are very scarce at present. In present experiment, we first analyzed the different cadmium forms in laver (Porphyra haitanensis and Porphyra yezoensis) which have high Cd accumulation capability by using size exclusion chromatography-high performance liquid chromatography-inductively coupled plasma mass spectrometry ( SEC-HPLC-ICP-MS). The result showed that three Cd species including Phytochelatins(PC)3-Cd,glutathione(GSH)-Cd and one small molecule Cd species were detected in the deionized water extraction of the laver. In vitro whole-bionic digestion model was used

  18. 高效液相色谱-电感耦合等离子体质谱联用技术测定玩具中痕量可迁移Cr(Ⅵ)%Determination of Trace Migratory Chromium(Ⅵ) in Toys by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    王欣; 幸苑娜; 陈泽勇; 霍巨垣; 陈丽琼

    2013-01-01

    建立了高效液相色谱-电感耦合等离子体质谱联用技术(HPLC-ICP-MS)测定玩具中痕量可迁移Cr(Ⅵ)的方法.采用Dionex AS19分析柱,在流动相为NH4NO3,pH=7A,流速为1.0 mL/min的条件下,可以很好地分离Cr(Ⅲ)和Cr(Ⅵ),且流动相浓度越小,分离度越大.所建立的方法简便、快速、灵敏度高,在色谱进样量为100 μL,质谱采用He碰撞池模式下,对Cr(Ⅵ)的检出限为0.02 μg/L;两个加标水平0.50和5.00 μg/L回收率分别为98.8% ~ 104.2%和96.3% ~ 100.4%,方法精密度优于4.2%,可以满足测定要求.应用本方法测定了玩具可接触部分材料包括涂层、塑料、木料、织物中的可迁移Cr(Ⅵ),分析结果令人满意.%A method for determinating trace migratory chromium(V0 in toys by hyphenated technique of high performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) has been developed in this article. The chromium species Cr(HI) and Cr(VO were separated on an Dionex AS19 analysis column using ammonium nitrate as the mobile phase with pH 7. 4 at flow rate 1. 0 mL/min. And the chromatographic separation was increased as the concentration of mobile phase was decreased. This method was easy to operate and with remarkably high sensitivity. The detection limit was found to be 0. 02 μg/L of Cr(VD for 100 μL injection volume in He collision cell mode of mass spectrometry. The spiked recoveries were at the range of 98. 8% -104. 2% and 96. 3% -100. 4% for the spiked levels of 0. 50 μg/L and 5. 00 ug/L respectively, and the RSDs were less than 4. 2% , which met the determination requirements. This method has been used to determine migratory Cr(Ⅵ) in accessible parts of toys, including coating, plastic, wood and textile. The results were satisfactory.

  19. High Performance Liquid Chromatography

    Science.gov (United States)

    Talcott, Stephen

    High performance liquid chromatography (HPLC) has many applications in food chemistry. Food components that have been analyzed with HPLC include organic acids, vitamins, amino acids, sugars, nitrosamines, certain pesticides, metabolites, fatty acids, aflatoxins, pigments, and certain food additives. Unlike gas chromatography, it is not necessary for the compound being analyzed to be volatile. It is necessary, however, for the compounds to have some solubility in the mobile phase. It is important that the solubilized samples for injection be free from all particulate matter, so centrifugation and filtration are common procedures. Also, solid-phase extraction is used commonly in sample preparation to remove interfering compounds from the sample matrix prior to HPLC analysis.

  20. Novel applications of high performance ion chromatography-inductively coupled plasma mass spectrometry (HPIC-ICP-MS)

    CERN Document Server

    Hann, S

    2001-01-01

    This work demonstrates the development of highly sensitive and selective analytical methods, which make use of the hyphenation of high performance ion chromatography (HPIC) to inductively coupled plasma sector field mass spectrometry (ICP-SFMS). On-line coupling a chromatographic separation method with an elemental detection method provides two advantages: (1) the components of a possibly interfering matrix can be separated allowing accurate and precise ultra trace analysis of the element of interest and (2) elemental species of an element can be separated and quantified. In this work, matrix separation methods for interference free determination of 232Th, 234U, 235U and 238U in geological matrices were developed and employed. Furthermore HPIC-ICP-SFMS was applied for ultra trace analysis of Pd in environmental and geological matrices. The usefulness of HPIC-ICP-SFMS for speciation studies was demonstrated by investigating the interaction of an anti-cancer drug (cisplatin) with guanosine monophosphates.

  1. HPLC-ICP/MS联用同时分析中药材中的多种形态砷%Analysis of arsenic speciation in traditional Chinese medicines by hyphenated technique of high performance liquid chromatography-inductively coupled plasma mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    郝春莉; 赵丽; 庄峙厦

    2011-01-01

    The hyphenated technique of high performance liquid chromatography coupled with inductively coupled plasma-mass spectrometry (HPLC-ICP-MS) were applied in the simultaneous determination of six arsenic species including As( Ⅲ ) 、As( Ⅴ ) 、DMA、MMA、AsB and AsC, in traditional Chinese medicines. The arsenic species in Traditional Chinese Medicinal samples were extracted using 1.2 mol/L hydrochloric acid and analyzed by the hyphenated technique of HPLC-ICP-MS with Hamilton PRP-X100 column. The arsenic species were separated well in the 800s,and the detection limits were 0. 2 ~ 0. 6 μg. Arsenate As(Ⅴ) and arsenite As(Ⅲ) were main arsenic species in all samples,and the inorganic arsenic recoveries were 64%. 1% ~91.7%. In addition, a little arsenobetaine (AsB) was found in animal herbs. The method can be applied to the quantitative determination and safety evaluation of inorganic arsenic or six arsenic species in TCMs.%利用高效液相色谱-电感耦合等离子体质谱(HPLC-ICP/MS)对中药材中的6种砷的形态(三价砷(As(Ⅲ))、五价砷(As(Ⅴ))、二甲基砷酸(DMA)、甲基砷酸(MMA)、砷甜菜碱(AsB)和砷胆碱(AsC))进行了同时分析.采用1.2mol/,L HCl浸提,Hamilton PRP-X100阴离子交换色谱柱分离后,根据ICP/MS保留时间的差别跟踪检测砷元素的各种形态.6种砷形态在800s内分离良好,检测限在0.2~0.6μg/L之间;中药材中的砷主要以有毒的无机砷(As(Ⅴ)和As(Ⅲ))形态存在,样品中无机砷的回收率在64.1%~91.7%之间,另外动物药材中还存在微量的AsB等有机砷形态.方法可用于中药材中无机砷或各种砷形态的同时分析.

  2. 体积排阻高效液相色谱-电感耦合等离子体质谱法测定海产贝类中镉的形态%Speciation Analysis of Cadmium in Marine Bivalves by Size Exclusion Chromatography-High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    赵艳芳; 尚德荣; 宁劲松; 翟毓秀

    2012-01-01

    The speciation analysis of cadmium in the scallop (Chlamys farreri, C. farreri) with high Cd accumulation capability and the clam (Ruditapes philippinarum, R. philippivarum) with low Cd accumulation capability was first conducted by size exclusion chromatography-high performance liquid chromatography-inductivcly coupled plasma mass spectrometry (SEC-HPLC-ICP-MS), and in vitro whole-bionic digestion model was used to determine the cadmium speciation in two bivalves under the action of saliva, the acidity of stomach and intestine with inorganic and organic components and diges-tion enzymes. The results showed that the total cadmium content in C. farreri was almost 10 times in R. philippinarum. Three Cd species, metallothionein (MT)-Cd, glutathione (GSH)-Cd and cystein (Cys)-Cd were detected in C. farreri, and two Cd species, MT-Cd and GSH-Cd were detected in R. philippinarum. According to the different peak areas, MT-Cd and GSH-Cd content in C. farreri was about 5. 6 and 2. 0 times of those in R. philippinarum respectively. Using in vitro whole-bionic diges-tion model, one unknown Cd species with small molecule (named Cd-X) was detected in whole-bionic digestion of gastric extracts, and four Cd species (mainly MT-Cd) were detected in the whole-bionic digestion of intestine extracts for C. farreri; however, for R. philippinarum, the unknown Cd-X was the main Cd species in both gastric and intestinal extracts. The experiment also proves that Cd can be separated from MT-Cd, GSH-Cd and Cys-Cd under the effect of the whole-bionic digestion of stomach and intestine.%运用体积排阻高效液相色谱-电感耦合等离子体质谱联用技术(SEC-HPLC-ICP-MS)分析了高镉积累扇贝和低镉积累菲律宾蛤仔中镉的存在形态,并结合体外全仿生消化技术,研究了在唾液、胃、肠无机物和有机物(含消化酶)作用下,扇贝和菲律宾蛤仔中镉的主要存在形态.结果发现:扇贝中Cd总量约为菲律宾蛤仔的10

  3. Liquid chromatography-inductively coupled plasma-based metallomic approaches to probe health-relevant interactions between xenobiotics and mammalian organisms.

    Science.gov (United States)

    Gómez-Ariza, José Luis; Jahromi, Elham Zeini; González-Fernández, Macarena; García-Barrera, Tamara; Gailer, Jürgen

    2011-06-01

    In mammals, the transport of essential elements from the gastrointestinal tract to organs is orchestrated by biochemical mechanisms which have evolved over millions of years. The subsequent organ-based assembly of sufficient amounts of metalloproteins is a prerequisite to maintain mammalian health and well-being. The chronic exposure of various human populations to environmentally abundant toxic metals/metalloid compounds and/or the deliberate administration of medicinal drugs, however, can adversely affect these processes which may eventually result in disease. A better understanding of the perturbation of these processes has the potential to advance human health, but their visualization poses a major problem. Nonetheless, liquid chromatography-inductively coupled plasma-based 'metallomics' methods, however, can provide much needed insight. Size-exclusion chromatography-inductively coupled plasma atomic emission spectrometry, for example, can be used to visualize changes that toxic metals/medicinal drugs exert at the metalloprotein level when they are added to plasma in vitro. In addition, size-exclusion chromatography-inductively coupled plasma mass spectrometry can be employed to analyze organs from toxic metal/medicinal drug-exposed organisms for metalloproteins to gain insight into the biochemical changes that are associated with their acute or chronic toxicity. The execution of such studies-from the selection of an appropriate model organism to the generation of accurate analytical data-is littered with potential pitfalls that may result in artifacts. Drawing on recent lessons that were learned by two research groups, this tutorial review is intended to provide relevant information with regard to the experimental design and the practical application of these aforementioned metallomics tools in applied health research.

  4. High-performance liquid chromatography of biopolymers

    Energy Technology Data Exchange (ETDEWEB)

    Regnier, F.E.

    1983-10-21

    The ability to separate biological macromolecules with good resolution on liquid chromatographic columns has depended on the development of suitable packing materials. In size exclusion chromatography, molecules are separated by size on the basis of differential permeation of the packing. Ion exchange, hydrophobic interaction (or reversed-phase), and affinity chromatography are all surface-mediated separation methods, although they depend on different retention mechanisms. High-performance liquid chromatographic columns designed for biopolymers offer major advantages over conventional columns in both speed and resolving power. The exponential growth of literature on the high-performance separation of peptides and proteins in particular indicates that the techniques will become the dominant form of column liquid chromatography. 92 refs., 4 figs.

  5. Basic prinicipal of high performance liquid chromatography

    OpenAIRE

    Ivanova, Violeta

    2016-01-01

    High-performance liquid chromatography (HPLC) is an analytical technique based on the separation of molecules due to differences in their structure and/or composition. Separation is performed between two phases, mobile and stationary. The molecules in the sample have different affinities and interactions with the stationary support, leading to separation of molecules. Compounds which are longer retained at the stationary phase will elute later, compared to those which are distributed into the...

  6. High Performance Liquid Chromatography/Video Fluorometry. Part I. Instrumentation.

    Science.gov (United States)

    1981-09-30

    High Performance Liquid Chromatography /Video...PERIOD COVERED High Performance Liquid Chromatography /Video .. / Fluorometry. Part I. Instrumentation. . Interim/ echnicaliepart,. 6. PERFORMING ORG...34Entered SECURITY CLASSIFICATION OF THIS OlAGE (When Data Entered) II1| III I I I I E I II ... .. High Performance Liquid Chromatography

  7. High Performance Liquid Chromatography/Video Fluorometry. Part II. Applications.

    Science.gov (United States)

    1981-09-30

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY /VIDEO FLUOROMETRY. PART...REP«T_N&:-ŗ/ High Performance Liquid Chromatography /Video Fluorometry» Part II. Applications« by | Dennis C./Shelly* Michael P./Vogarty and...Data EnlirtdJ REPORT DOCUMENTATION PAGE t. REPORT NUMBER 2 GOVT ACCESSION NO 4. T1TI.F (and Submit) lP-^fffsyva High Performance Liquid Chromatography

  8. High-Performance Liquid Chromatography: An Overview

    OpenAIRE

    Tandia N; Singh SK1; Kumar N; Singh S

    2013-01-01

    Chromatography is considered extremely powerful separation technique for variety of samples. Thecommon feature of all these techniques is that the different components in a sample mixture aredistributed between two phases, one of which remains stationary while the other the mobile phase, runsthrough the interstices or over the surface of the fixed phase. The movement of the mobile phase resultsin differential migration of the sample components. High performance thin layer chromatography is an...

  9. Determination of Total Arsenic and Speciation in Apple Juice by Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry: An Experiment for the Analytical Chemistry Laboratory

    Science.gov (United States)

    He, Ping; Colon, Luis A.; Aga, Diana S.

    2016-01-01

    A two-part laboratory experiment was designed for upper-level analytical chemistry students to provide hands-on experience in the use of high performance liquid chromatography (HPLC) for separation and inductively coupled plasma mass spectrometry (ICP-MS) for detection. In the first part of the experiment, the students analyze total arsenic in…

  10. ANALYSIS OF AMINO ACIDS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    Qurat E Noor Baig

    2016-06-01

    Full Text Available Amino acids are the building blocks of proteins and are considered as the key precursors for the formation of hormones and low molecular weight nitrogenous substances with biological importance. Since the analysis of amino acids has been carried out for both qualitative and quantitative purposes with an aim to study their levels in the plasma concentration, the quantitative determination, in particular, also helps in the diagnosis of different diseases associated with their deficiency. This review article deals with the determination of amino acids by chromatographic methods which include ion-exchange chromatography (IEC, high performance liquid chromatography (HPLC, reverse phase-high performance liquid chromatography (RP-HPLC and ultra-performance liquid chromatography (UPLC. The review will also give an idea for the preparation of samples, derivatization methods for the analysis of amino acids (direct and indirect methods and separation of amino acids by high performance liquid chromatographic technique.

  11. Mallow carotenoids determined by high-performance liquid chromatography

    Science.gov (United States)

    Mallow (corchorus olitorius) is a green vegetable, which is widely consumed either fresh or dry by Middle East population. This study was carried out to determine the contents of major carotenoids quantitatively in mallow, by using a High Performance Liquid Chromatography (HPLC) equipped with a Bis...

  12. Determination of Caffeine in Beverages by High Performance Liquid Chromatography.

    Science.gov (United States)

    DiNunzio, James E.

    1985-01-01

    Describes the equipment, procedures, and results for the determination of caffeine in beverages by high performance liquid chromatography. The method is simple, fast, accurate, and, because sample preparation is minimal, it is well suited for use in a teaching laboratory. (JN)

  13. Multichannel Detection in High-Performance Liquid Chromatography.

    Science.gov (United States)

    Miller, James C.; And Others

    1982-01-01

    A linear photodiode array is used as the photodetector element in a new ultraviolet-visible detection system for high-performance liquid chromatography (HPLC). Using a computer network, the system processes eight different chromatographic signals simultaneously in real-time and acquires spectra manually/automatically. Applications in fast HPLC…

  14. High-Performance Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Vestal, Marvin L.

    1984-01-01

    Reviews techniques for online coupling of high-performance liquid chromatography with mass spectrometry, emphasizing those suitable for application to nonvolatile samples. Also summarizes the present status, strengths, and weaknesses of various techniques and discusses potential applications of recently developed techniques for combined liquid…

  15. Analysis of Tocopherols by High Performance Liquid Chromatography

    OpenAIRE

    Edison, B.

    2009-01-01

    : Gas chromatography is the key technique for organic components and also for tocopherols analysis. High performance liquid chromatography has an important role to take part in applications such as the handling of less usual samples, prevention of degradation of heat sensitive functional groups and for micro preparative purposes. Many approaches for development of improved methods are suggested, especially for reversed phase applications.

  16. Ultra high performance liquid chromatography of seized drugs

    NARCIS (Netherlands)

    Lurie, I.S.

    2010-01-01

    The primary goal of this thesis is to investigate the use of ultra high performance liquid chromatography (UHPLC) for the analysis of seized drugs. This goal was largely achieved and significant progress was made in achieving improved separation and detection of drugs of forensic interest.

  17. Quantification of Tea Flavonoids by High Performance Liquid Chromatography

    Science.gov (United States)

    Freeman, Jessica D.; Niemeyer, Emily D.

    2008-01-01

    We have developed a laboratory experiment that uses high performance liquid chromatography (HPLC) to quantify flavonoid levels in a variety of commercial teas. Specifically, this experiment analyzes a group of flavonoids known as catechins, plant-derived polyphenolic compounds commonly found in many foods and beverages, including green and black…

  18. Resolution of RNA using high-performance liquid chromatography

    NARCIS (Netherlands)

    Mclaughlin, L.W.; Bischoff, Rainer

    1987-01-01

    High-performance liquid chromatographic techniques can be very effective for the resolution and isolation of nucleic acids. The characteristic ionic (phosphodiesters) and hydrophobic (nucleobases) properties of RNAs can be exploited for their separation. In this respect anion-exchange and reversed-p

  19. Temperature-Modulated Array High-Performance Liquid Chromatography

    OpenAIRE

    Premstaller, Andreas; Xiao, Wenzhong; Oberacher, Herbert; O'Keefe, Matthew; Stern, David; Willis, Thomas; Huber, Christian G.; Peter J. Oefner

    2001-01-01

    Using novel monolithic poly(styrene-divinylbenzene) capillary columns with an internal diameter of 0.2 mm, we demonstrate for the first time the feasibility of constructing high-performance liquid chromatography arrays for the detection of mutations by heteroduplex analysis under partially denaturing conditions. In one embodiment, such an array can be used to analyze one sample simultaneously at different temperatures to maximize the detection of mutations in DNA fragments containing multiple...

  20. Analysis of Tocopherols by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    B. Edison

    2009-01-01

    Full Text Available : Gas chromatography is the key technique for organic components and also for tocopherols analysis. High performance liquid chromatography has an important role to take part in applications such as the handling of less usual samples, prevention of degradation of heat sensitive functional groups and for micro preparative purposes. Many approaches for development of improved methods are suggested, especially for reversed phase applications.

  1. Trends in High Performance Liquid Chromatography for Cultural Heritage.

    Science.gov (United States)

    Degano, Ilaria; La Nasa, Jacopo

    2016-04-01

    The separation, detection and quantitation of specific species contained in a sample in the field of Cultural Heritage requires selective, sensitive and reliable methods. Procedures based on liquid chromatography fulfil these requirements and offer a wide range of applicability in terms of analyte types and concentration range. The main applications of High Performance Liquid Chromatography in this field are related to the separation and detection of dyestuffs in archaeological materials and paint samples by reversed-phase liquid chromatography with suitable detectors. The relevant literature will be revised, with particular attention to sample treatment strategies and future developments. Reversed phase chromatography has also recently gained increasing importance in the analysis of lipid binders and lipid materials in archaeological residues: the main advantages and disadvantages of the new approaches will be discussed. Finally, the main applications of ion chromatography and size exclusion chromatography in the field of Cultural Heritage will be revised in this chapter.

  2. Thermal expansion pump for capillary high-performance liquid chromatography.

    Science.gov (United States)

    Tao, Qian; Wu, Qian; Zhang, Xiangmin

    2010-02-01

    A thermal expansion pump (TEP) based on a principle of liquid thermal expansion for capillary high-performance liquid chromatography has been developed. The novel pump is capable of generating a continuous flow at high pressure for constant and stable delivery of binary solvents from nanoliters to microliters per minute without splitting. Theoretical equations for controlling fluidic output of this pump have been established and validated by a series of experiments. Factors affecting flow rate, such as density discrepancy, liquid compressibility, and mass loss in output, were taken into account. An assembly of the pump system employing two groups of thermal expansion pumps (TEPs) working in turns were fabricated, and a controlling strategy for the pump system to maintain a continuous delivery without pressure fluctuation even at switching points was also developed. Both isocratic and gradients of binary solvent delivery by the TEPs were performed. Reproducibility and standard deviation at different flow rates were determined. A capillary high-performance liquid chromatography (micro-HPLC) system consisting of the TEPs, an injection valve, a homemade packed capillary column (20 cm x 100 microm i.d. with 5 microm C18), and a laser-induced fluorescence detector was set up, and sample separations were carried out. Results of RSD = 4% for flow and RSD = 2% for retention times at 500 nL/min were achieved. Such a pump system has almost no moving parts except for the solvent switches. Its overall costs of manufacture and running are very low. It is proven that the TEPs system has great potential and competitive capabilities in capillary liquid chromatography.

  3. Quantification of tryptophan in plasma by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Renata Romanholi Pinhati

    2012-01-01

    Full Text Available A simple, rapid and selective method using high-performance liquid chromatography with ultraviolet detection (267 nm was applied for the determination of tryptophan in plasma. Separation was carried out on a C18 column (150 x 4.6 mm internal diameter in 6 min. The mobile phase consisted of 5 mM the sodium acetate and acetonitrile (92:8, v/v. The method was shown to be precise and accurate, and good recovery of analyte was achieved, characterizing the method as efficient and reliable for use in laboratory analysis.

  4. Gas and high-performance liquid chromatography of phenols

    Energy Technology Data Exchange (ETDEWEB)

    Tesarova, E.; Pacakova, V.

    1983-05-01

    Gas (GC) and high-performance liquid chromatographic (HPLC) methods in the analysis of phenols are reviewed. Among the great number of phenolic compounds analyzed, alkylphenols, chlorophenols, dihydroxy-and trihydroxy-benzenes and biphenols are chiefly considered. The advantages and drawbacks of the methods are discussed. Relationships between the structural characteristics of phenols, the stationary phase structure, the mobile phase composition and the retention data are treated. Typical examples of the conditions for GC and HPLC analysis are summarized in tables. 276 references

  5. Determination of pyrazinamide in human by high performance liquid chromatography.

    Directory of Open Access Journals (Sweden)

    Revankar S

    1994-01-01

    Full Text Available A facile and sensitive high performance liquid chromatographic (HPLC technique has been developed for the determination pyrazinamide (PZA in human plasma. Nicotinamide(NIA is used as internal standard(IS. Plasma is deproteinized with 0.7 M perchloric acid; clear supernatant is neutralized with 1M NaOH and injected onto HPLC. The separation of pyrazinamide and the internal standard is carried out on a Supelco LC-18 (DB column with a basic mobile phase. Pyrazinoic acid, the major metabolite, other anti-tuberculous drugs and endogenous components do not interfere with measurement of pyrazinamide. The limit of detection of pyrazinamide with this method is 0.2 mg/0.2 ml plasma (CV 8.2%.

  6. [Determination of amygdalin in hawthorn by high performance liquid chromatography].

    Science.gov (United States)

    Lü, Weifeng; Ding, Mingyu

    2005-09-01

    A suitable method for extraction of amygdalin from hawthorn has been established. At first, the lipophilic components were removed with petroleum ether by ultrasonic extraction. The amygdalin was then extracted by methanol in a Soxhlet's apparatus. For quantitation, a high performance liquid chromatographic method was developed by using a reversed-phase C18 column, mobile phase of methanol-water (15:85, v/v) and a detection wavelengh of 215 nm. It can be concluded that the content of amygdalin is higher in the seeds than that in the hawthorn powder without the seeds and the yield of amygdalin is higher in the hawthorn pieces than that in the hawthorn powder.

  7. Analysis of Free Fatty Acids on the Fingertips by High Performance Liquid Chromatography.

    Science.gov (United States)

    1978-12-20

    This investigation studied the efficiency of high performance liquid chromatography in the determination of free fatty acids present on the...utilized to eliminate the microbial contamination. The high performance liquid chromatography provided excellent separation of skin fatty acids for

  8. Determination of vanadium species in sediment, mussel and fish muscle tissue samples by liquid chromatography-inductively coupled plasma-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Colina, Marinela [Universidad del Zulia, Facultad de Ciencias, Departamento de Quimica, Laboratorio de Quimica Ambiental, Maracaibo 4011, Zulia (Venezuela)]. E-mail: M.Colina@shu.ac.uk; Gardiner, P.H.E. [Sheffield Hallam University, Howard Street, Sheffield S1 1WB, Sheffield (United Kingdom); Rivas, Zulay [Instituto para la Conservacion del Lago de Maracaibo (ICLAM), Maracaibo, Plaza de las Banderas (Venezuela); Troncone, Federico [Instituto para la Conservacion del Lago de Maracaibo (ICLAM), Maracaibo, Plaza de las Banderas (Venezuela)

    2005-05-04

    Vanadium is introduced into the environment during the extraction of petrochemical products and in the production of steels and insecticides. In this study, a liquid chromatographic method for the separation of V(IV) and V(V) as ethylenediaminetetra acetic acid (EDTA) complexes was developed using reversed-phase ion-pair liquid chromatography with inductively coupled plasma-mass spectrometry detection. A C-8 reversed-phase column, 15 cm long, was used to separate the species. A solution containing ammonium acetate 0.06 M, tetrabutylammonium hydroxide 10 mM, ammonium di-phosphate 10 mM and EDTA 2.5 mM at pH 6 was used as the mobile phase in order to avoid the use of organic solvents that reduce the sensitivity of the determination. To prevent changes in distribution of the vanadium species, samples should be prepared freshly. The method developed was applied to the study the vanadium speciation in sediment, mussel and fish muscle samples collected from Lake Maracaibo, Venezuela. The concentration ranges of V(IV) and V(V) in sediment samples were 0.7-61 and 1.4-2.3 {mu}g g{sup -1}, respectively. The method is simple and has adequate sensitivity for these practical applications.

  9. Determination of a Jet Fuel Metal Deactivator by High Performance Liquid Chromatography

    Science.gov (United States)

    1983-06-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Paul C. Hayes, Jr. Fuels Branch...SUPPLEMENTARY NOTES 19. KEY WORDS (Continue on reverse side if necessary and identify by block number) High Performance Liquid Chromatography absorbance...SYMBOL HPLC High Performance Liquid Chromatography P-4 jet propulsion fuel, wide-boiling range, conforming to MIL-T-5624L MDA metal deactivator,

  10. Determination of Stabiliser Contents in Advanced Gun Propellants by Reverse Phase High Performance Liquid Chromatography

    Science.gov (United States)

    1994-03-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY N"m A.R. TURNER AND A. WHITE...TO biEPROOU.; AND SELL THIS REPORT Determination of Stabiliser Contents in Advanced Gun Propellants by Reverse Phase High Performance Liquid Chromatography A.R...8217/......... .. Availability Cooes Dist Avaiardlo A-i Determination of Stabiliser Contents in Advanced Gun Propellants by Reverse Phase High Performance Liquid Chromatography

  11. High-temperature liquid chromatography inductively coupled plasma atomic emission spectrometry hyphenation for the combined organic and inorganic analysis of foodstuffs.

    Science.gov (United States)

    Terol, Amanda; Paredes, Eduardo; Maestre, Salvador E; Prats, Soledad; Todolí, José L

    2010-10-01

    The coupling of a High-Temperature Liquid Chromatography system (HTLC) with an Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES) is reported for the first time. This hyphenation combines the separation efficiency of HTLC with the detection power of a simultaneous ICP-AES system and allows the combined determination of organic compound and metals. The effluents of the column were introduced into the spectrometer and the chromatograms for organic compounds were obtained by plotting the carbon emission signal at a characteristic wavelength versus time. As regards metals, they were determined by injecting a small sample volume between the exit of the column and the spectrometer and taking the emission intensity for each one of the elements simultaneously. Provided that in HTLC the effluents emerged at high temperatures, an aerosol was easily generated at the exit of the column. Therefore, the use of a pneumatic nebulizer as a component of a liquid sample introduction system in the ICP-AES could be avoided, thus reducing the peak dispersion and limits of detection by a factor of two. The fact that a hot liquid stream was nebulized made it necessary to use a thermostated spray chamber so as to avoid the plasma cooling as a cause of the excessive mass of solvent delivered to it. Due to the similarity in sample introduction, an Evaporative Light Scattering Detector (ELSD) was taken as a reference. Comparatively speaking, limits of detection were of the same order for both HTLC-ICP-AES and HTLC-ELSD, although the latter provided better results for some compounds (from 10 to 20 mg L(-1) and 5-10 mg L(-1), respectively). In contrast, the dynamic range for the new hyphenation was about two orders of magnitude wider. More importantly, HTLC-ICP-AES provided information about the content of both organic (glucose, sucrose, maltose and lactose at concentrations from roughly 10 to 400 mg L(-1)) as well as inorganic (magnesium, calcium, sodium, zinc, potassium and

  12. Determination of Finasteride in Tablets by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    K. Basavaiah

    2007-01-01

    Full Text Available A rapid, highly sensitive high performance liquid chromatographic method has been developed for the determination of finasteride(FNS in bulk drug and in tablets. FNS was eluted from a ODS C18 reversed phase column at laboratory temperature (30 ± 2°C with a mobile phase consisting of methanol and water (80+20 at a flow rate of 1 mL min-1 with UV detection at 225 nm. The retention time was ∼ 6.1 min and each analysis took not more than 10 min. Quantitation was achieved by measurement of peak area without using any internal standard. Calibration graph was linear from 2.0 to 30 μg mL-1 with limits of detection (LOD and quantification (LOQ being 0.2 and 0.6 μg mL-1, respectively. The method was validated according to the current ICH guidelines. Within-day co efficients of variation (CV ranged from 0.31 to 0.69% and between-day CV were in the range 1.2-3.2%. Recovery of FNS from the pharmaceutical dosage forms ranged from 97.89 – 102.9 with CV of 1.41-4.13%. The developed method was compared with the official method for FNS determination in its tablet forms.

  13. Determination of saffron quality by high-performance liquid chromatography.

    Science.gov (United States)

    Valle García-Rodríguez, M; Serrano-Díaz, Jéssica; Tarantilis, Petros A; López-Córcoles, Horacio; Carmona, Manuel; Alonso, Gonzalo L

    2014-08-13

    The aim of this work was to propose a high-performance liquid chromatography with diode array detection (HPLC-DAD) method for determining the three main compounds responsible for determining the quality of saffron (crocetin esters, picrocrocin, and safranal) by preparing an aqueous extract according to the ISO 3632 standard to solve the difficulty that this standard has for aroma and taste determination by ultraviolet-visible spectroscopy. Toward this aim, laboratory-isolated picrocrocin, a safranal standard with a purity of ≥ 88%, trans-crocetin di(β-D-gentiobiosyl) ester (trans-4-GG) and trans-crocetin (β-D-glucosyl)-(β-D-gentiobiosyl) ester (trans-3-Gg) standards, both with a purity of ≥ 99%, and 50 different saffron spice samples from Italy, Iran, Greece, and Spain were used in the intralaboratory validation of the HPLC method. The analytical method proposed was adequate in terms of linearity, selectivity, sensitivity, and accuracy for determining the three foremost parameters that define the quality of saffron using only a saffron solution prepared according to the ISO 3632 standard.

  14. Gradient chromatofocusing high-performance liquid chromatography. I. Practical aspects.

    Science.gov (United States)

    Liu, Y; Anderson, D J

    1997-02-21

    In this work, a versatile method for generating linear pH gradients using weak anion-exchange HPLC has been developed, which is termed gradient chromatofocusing high-performance liquid chromatography. This method utilizes a linear external pH gradient generated in the mobile phase entering the column (inlet pH gradient), superimposed on an internally-generated pH gradient within the column (column pH gradient), which results from the buffering action of the ion exchanger on the mobile phase and vice versa. The method shows significant advantages over conventional chromatofocusing, including: decreased expense due to the use of common buffer components, ease of adjusting the slope of the pH gradient produced at the outlet of the column (outlet pH gradient) through the manipulation of the inlet pH gradient and the ability of using high concentration buffers in the mobile phase. Chromatography of fibrinogen degradation products was done using gradient chromatofocusing. Bandwidths comparable to conventional chromatofocusing were obtained in the separation of fibrinogen degradation products.

  15. Gradient chromatofocusing high-performance liquid chromatography. II. Theoretical aspects.

    Science.gov (United States)

    Liu, Y; Anderson, D J

    1997-02-21

    This article is Part II of a series describing a newly-developed gradient chromatofocusing high-performance liquid chromatography (HPLC) technique. Theoretical aspects of the technique are discussed. In gradient chromatofocusing, the column pH gradient with respect to column distance can be varied without necessarily affecting the outlet pH gradient with respect to time. Factors influencing the value of the slope of the column pH gradient are identified through derived equations and a computer simulation model. A newly-identified parameter is introduced, column travel time, which can be uniquely varied in gradient chromatofocusing. Experiments show increased conversion of fibrinogen to denatured forms with increased column travel time. Another unique aspect of gradient chromatofocusing is that the mobile phase buffer concentration can be manipulated without necessarily affecting the outlet pH gradient slope, giving the technique expanded versatility for optimizing the separation. In the present work, the pIapparent for fibrinogen is found to increase with increased mobile phase buffer concentration.

  16. High Performance Liquid Chromatography Experiments to Undergraduate Laboratories

    Science.gov (United States)

    Kissinger, Peter T.; And Others

    1977-01-01

    Reviews the principles of liquid chromatography with electrochemical detection (LCEC), an analytical technique that incorporates the advantages of both liquids chromatography and electrochemistry. Also suggests laboratory experiments using this technique. (MLH)

  17. Determination of Selected Colored Smokes on Glass Fiber Discs by High Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    1991-05-01

    High Performance Liquid Chromatography (HPLC) 12. PERSONAL AUTHOR(S) F F_ n.ipl’prifl. Alan R...GROUP SUB-GROUP High Performance Liquid Chromatography (HPLC), Analytical IMethod, 1,4-diamino-2,3-dihydroanthraquinone, 2-(2 - _ quinolinyl)-1,3...weights, low vapor pressures and low thermal stability. High performance liquid chromatography (HPLC) appears to be the analytical method of choice

  18. High Performance Liquid Chromatography of Vitamin A: A Quantitative Determination.

    Science.gov (United States)

    Bohman, Ove; And Others

    1982-01-01

    Experimental procedures are provided for the quantitative determination of Vitamin A (retinol) in food products by analytical liquid chromatography. Standard addition and calibration curve extraction methods are outlined. (SK)

  19. Sheath liquid effects in capillary high-performance liquid chromatography-electrospray mass spectrometry of oligonucleotides.

    Science.gov (United States)

    Huber, C G; Krajete, A

    2000-02-18

    Fused-silica capillary columns of 200 microm inner diameter were packed with micropellicular, octadecylated, 2.3 microm poly(styrene-divinylbenzene) particles and applied to the separation of oligonucleotides by ion-pair reversed-phase high-performance liquid chromatography. Oligonucleotides were eluted at 50 degrees C with gradients of 3-13% acetonitrile in 50 mM triethylammonium bicarbonate. Addition of sheath liquid to the column effluent allowed the detection of oligonucleotides by electrospray ionization mass spectrometry using full-scan data acquisition with a detectability comparable to that obtained with UV detection. The signal-to-noise ratios with different sheath liquids increased in the order isopropanolliquid was found to influence the charge state distribution of oligonucleotides longer than 20 nucleotide units whereas no significant effect was observed with shorter oligonucleotides. Organic acids and bases in the sheath liquid generally deteriorated the signal-to-noise ratios in the chromatograms and mass spectra mainly because of increased background noise. Only a few charge states were observed in the mass spectra of oligonucleotides because of charge state reduction due to the presence of carbonic acid in the eluent. With triethylammonium hydrogencarbonate as chromatographic eluent and acetonitrile as sheath liquid, very few cation adducts of oligonucleotides were observed in the mass spectra. However, the presence of small amounts of monopotassium adducts enabled the calculation of the charge state of multiply charged ions. With acetonitrile as sheath liquid, 710 amol of a 16-mer oligonucleotide were detected using selected ion monitoring data acquisition with a signal-to-noise ratio of 3:1. Finally, capillary ion-pair reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry was

  20. High-performance liquid chromatography with packed microchips

    OpenAIRE

    Ehlert, Steffen

    2011-01-01

    This work is explaining the importance of generating a densely packed chromatographic bed to achieve optimum separation efficiency in miniaturized liquid chromatography. The reduction of peak dispersion and enhancement of separation efficiency is the important problem in micro- and nano-separation that is to be solved to generate highly efficient chromatographic systems that can exploit all advantages of miniaturization. Therefore...

  1. High performance ultracapacitors with carbon nanomaterials and ionic liquids

    Science.gov (United States)

    Lu, Wen; Henry, Kent Douglas

    2012-10-09

    The present invention is directed to the use of carbon nanotubes and/or electrolyte structures in various electrochemical devices, such as ultracapacitors having an ionic liquid electrolyte. The carbon nanotubes are preferably aligned carbon nanotubes. Compared to randomly entangled carbon nanotubes, aligned carbon nanotubes can have better defined pore structures and higher specific surface areas.

  2. High performance batteries with carbon nanomaterials and ionic liquids

    Science.gov (United States)

    Lu, Wen

    2012-08-07

    The present invention is directed to lithium-ion batteries in general and more particularly to lithium-ion batteries based on aligned graphene ribbon anodes, V.sub.2O.sub.5 graphene ribbon composite cathodes, and ionic liquid electrolytes. The lithium-ion batteries have excellent performance metrics of cell voltages, energy densities, and power densities.

  3. High Performance Negative Dielectric Anisotropy Liquid Crystals for Display Applications

    Directory of Open Access Journals (Sweden)

    Xiaolong Song

    2013-09-01

    Full Text Available We review recent progress in the development of high birefringence (Δn ≥ 0.12 negative dielectric anisotropy (Δε < 0 liquid crystals (LCs for direct-view and projection displays. For mobile displays, our UCF-N2 (low viscosity, negative Δε, high Δn based homogeneous alignment fringe-field switching (called n-FFS mode exhibits superior performance to p-FFS in transmittance, single gamma curve, cell gap insensitivity, and negligible flexoelectric effect. For projection displays using a vertical alignment liquid-crystal-on-silicon (VA LCOS, our high birefringence UCF-N3 mixture enables a submillisecond gray-to-gray response time, which is essential for color sequential displays without noticeable color breakup. Our low viscosity UCF-N2 also enables multi-domain VA displays to use a thinner cell gap for achieving faster response time.

  4. High Performance Mars Liquid Cooling and Ventilation Garment Project

    Science.gov (United States)

    Terrier, Douglas; Clayton, Ronald; Whitlock, David; Conger, Bruce

    2015-01-01

    EVA space suit mobility in micro-gravity is enough of a challenge and in the gravity of Mars, improvements in mobility will enable the suited crew member to efficiently complete EVA objectives. The idea proposed is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area in order to free up the arms and legs by removing the liquid tubes currently used in the ISS EVA suit in the limbs. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased to provide the entire liquid cooling requirement and increase mobility by freeing up the arms and legs. Additional potential benefits of this approach include reduced LCVG mass, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development.

  5. Rapid analysis of phentolamine by high-performance liquid chromatography.

    Science.gov (United States)

    Webster, Gregory K; Lemmer, Robert R; Greenwald, Steven

    2003-02-01

    A rapid liquid chromatographic method is validated for the quantitative analysis of phentolamine. Phentolamine exists in three forms for this investigation: as a mesylate salt, hydrochloride salt, and free base. In solution, phentolamine dissociates from its salt and is chromatographed as free phentolamine. This validation confirms the analysis of each form, which is simply based upon molar mass differences encountered in weighing. As such, both the United States Pharmacopeia hydrochloride and mesylate standards are used throughout this validation to demonstrate this equivalency. The validation demonstrates that this method may be used to quantitate phentolamine, regardless of its salt form.

  6. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY DETECTORS – A REVIEW

    Directory of Open Access Journals (Sweden)

    Kaushal Ramni

    2011-05-01

    Full Text Available HPLC is the most versatile and widely used elution chromatography. The technique is used to resolve and determine species in a variety of organic, inorganic, biological, ionic and polymeric materials. Detector is the heart of an instrument and efficiency of system is dependent upon detecting techniques. Many types of HPLC detectors exist, each of which has some valuable performance feature such as refractive index detector, ultraviolet detector, fluorescent detector, electrochemical detector, electric conductivity detector, liquid light scattering detector, evaporative light scattering detector. Due to strong requirement for improvements in sensitivity, selectivity and other performance characteristics of the detector recent developments in conventional techniques and some other new technologies have been adopted such as laser light scattering detector, charged aerosol detector, nano quantity aerosol detector, chiral detector and pulsed amperometric detector. These detectors provide accurate concentration analysis, excellent sensitivity, wide dynamic range, consistent response and broad applicability of the drug components. Working of these detectors involve different principles such as optical techniques, aerosol based techniques, refractive methods, light scattering principle, amperometric and fluorescence. The present review enlightens both conventional and advanced techniques and compares their capabilities of analyzing drug components and need for new techniques for better and wide range of applicability.

  7. Optimized determination of polybrominated diphenyl ethers by ultrasound-assisted liquid-liquid extraction and high-performance liquid chromatography.

    Science.gov (United States)

    He, Kuang; Lv, YuanCai; Chen, YuanCai

    2014-10-01

    A method based on ultrasound-assisted liquid-liquid extraction and high-performance liquid chromatography has been optimized for the determination of six polybrominated diphenyl ether congeners. The optimal condition relevant to the extraction was first investigated, more than 98.7 ± 0.7% recovery was achieved with dichloromethane as extractant, 5 min extraction time, and three cycles of ultrasound-assisted liquid-liquid extraction. Then multiple function was employed to optimize polybrominated diphenyl ether detection conditions with overall resolution and chromatography signal area as the responses. The condition chosen in this experiment was methanol/water 93:7 v/v, flow rate 0.80 mL/min, column temperature 30.0°C. The optimized technique revealed good linearity (R(2) > 0.9962 over a concentration range of 1-100 μg/L) and repeatability (relative standard deviation liquid-liquid extraction coupled with high-performance liquid chromatography was effective to identify and quantify the complex polybrominated diphenyl ethers in effluent samples.

  8. Application of High Performance Liquid Chromatography to Separation of Novel Chiral Tetrahedral Heterometal Clusters

    Institute of Scientific and Technical Information of China (English)

    Xin Yi ZHU; Wei Qiang ZHANG; Yu Hua ZHANG; Li Ren CHEN; Yong Min LI

    2003-01-01

    A series of novel chiral tetrahedral heterometal clusters have firstly been separated oncellulose tris-(3,5-dimethylphenylcarbamate) stationary phase by high performance liquid chrom-atography, using hexane as the mobile phase with various alcohols as modifiers.

  9. Determination of sulfonamides in butter samples by ionic liquid magnetic bar liquid-phase microextraction high-performance liquid chromatography.

    Science.gov (United States)

    Wu, Lijie; Song, Ying; Hu, Mingzhu; Xu, Xu; Zhang, Hanqi; Yu, Aimin; Ma, Qiang; Wang, Ziming

    2015-01-01

    A novel, simple, and environmentally friendly pretreatment method, ionic liquid magnetic bar liquid-phase microextraction, was developed for the determination of sulfonamides in butter samples by high-performance liquid chromatography. The ionic liquid magnetic bar was prepared by inserting a stainless steel wire into the hollow of a hollow fiber and immobilizing ionic liquid in the micropores of the hollow fiber. In the extraction process, the ionic liquid magnetic bars were used to stir the mixture of sample and extraction solvent and enrich the sulfonamides in the mixture. After extraction, the analyte-adsorbed ionic liquid magnetic bars were readily isolated with a magnet from the extraction system. It is notable that the present method was environmentally friendly since water and only several microliters of ionic liquid were used in the whole extraction process. Several parameters affecting the extraction efficiency were investigated and optimized, including the type of ionic liquid, sample-to-extraction solvent ratio, the number of ionic liquid magnetic bars, extraction temperature, extraction time, salt concentration, stirring speed, pH of the extraction solvent, and desorption conditions. The recoveries were in the range of 73.25-103.85 % and the relative standard deviations were lower than 6.84 %. The experiment results indicated that the present method was effective for the extraction of sulfonamides in high-fat content samples.

  10. Determination of dodecylbenzenesulphonates and ethoxylated alkylphenols in liquid pesticide formulations by high-performance liquid chromatography.

    Science.gov (United States)

    Schreuder, R H; Martijn, A

    1988-01-01

    A method is presented for determining mixtures of calcium dodecylbenzene-sulphonate (CaDBS) and ethoxylated alkylphenols in pesticidal emulsifiable concentrates. The pesticide formulations are adsorbed on a pre-concentration column. The active ingredients, the solvents and the emulsifiers are eluted successively by using solvents with increasing polarities. The various homologues of CaDBS and the ethoxylated alkylphenols are separated by reversed-phase high performance liquid chromatography using methanol-water containing tetramethylammonium bromide. The oligomers of the ethoxylated phenols are separated on an aminopropyl-modified column using a solvent gradient (propan-2-ol-water and hexane-tetrahydrofuran). Quantitative results are given for synthetic samples. The degree of ethoxylation of the ethoxylated alkylphenols has been determined and the CaDBS components characterized.

  11. Dispersive Liquid-Liquid Microextraction and determination of Platinum(IV by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Ali Mazloomifar

    2015-09-01

    Full Text Available A simple, rapid, and efficient procedure, dispersive liquid-liquid microextraction (DLLME, has been developed for the extraction and preconcentration of platinum (IV in environmental water samples. The factors relevant to the microextraction efficiency, such as the kind and volume of extraction and dispersive solvent, the extraction time, the pH in aqueous, and the salt effect, were optimized. Under the optimum conditions , the enrichment factor of this method for platinum was reached at 119. The detection limit for platinum was 0.3 ng mL-1 , and the relative standard deviation (RSD was 0.42% (n = 10 , C = 10 ng mL-1. The method was successfully applied to the determination of trace amounts of platinum in environmental water samples.

  12. High performance liquid-level sensor based on mPOFBG for aircraft applications

    DEFF Research Database (Denmark)

    Marques, C. A. F.; Pospori, A.; Saez-Rodriguez, D.

    2015-01-01

    A high performance liquid-level sensor based on microstructured polymer optical fiber Bragg grating (mPOFBG) array sensors is reported in detail. The sensor sensitivity is found to be 98pm/cm of liquid, enhanced by more than a factor of 9 compared to a reported silica fiber-based sensor....

  13. Crosslinked polymeric ionic liquids as solid-phase microextraction sorbent coatings for high performance liquid chromatography.

    Science.gov (United States)

    Yu, Honglian; Merib, Josias; Anderson, Jared L

    2016-03-18

    Neat crosslinked polymeric ionic liquid (PIL) sorbent coatings for solid-phase microextraction (SPME) compatible with high-performance liquid chromatography (HPLC) are reported for the first time. Six structurally different PILs were crosslinked to nitinol supports and applied for the determination of select pharmaceutical drugs, phenolics, and insecticides. Sampling conditions including sample solution pH, extraction time, desorption solvent, desorption time, and desorption solvent volume were optimized using design of experiment (DOE). The developed PIL sorbent coatings were stable when performing extractions under acidic pH and remained intact in various organic desorption solvents (i.e., methanol, acetonitrile, acetone). The PIL-based sorbent coating polymerized from the IL monomer 1-vinyl-3-(10-hydroxydecyl) imidazolium chloride [VC10OHIM][Cl] and IL crosslinker 1,12-di(3-vinylbenzylimidazolium) dodecane dichloride [(VBIM)2C12] 2[Cl] exhibited superior extraction performance compared to the other studied PILs. The extraction efficiency of pharmaceutical drugs and phenolics increased when the film thickness of the PIL-based sorbent coating was increased while many insecticides were largely unaffected. Satisfactory analytical performance was obtained with limits of detection (LODs) ranging from 0.2 to 2 μg L(-1) for the target analytes. The accuracy of the analytical method was examined by studying the relative recovery of analytes in real water samples, including tap water and lake water, with recoveries varying from 50.2% to 115.9% and from 48.8% to 116.6%, respectively.

  14. Application of Ionic Liquids in High Performance Reversed-Phase Chromatography

    Science.gov (United States)

    Wang, Ye; Tian, Minglei; Bi, Wentao; Row, Kyung Ho

    2009-01-01

    Ionic liquids, considered “green” chemicals, are widely used in many areas of analytical chemistry due to their unique properties. Recently, ionic liquids have been used as a kind of novel additive in separation and combined with silica to synthesize new stationary phase as separation media. This review will focus on the properties and mechanisms of ionic liquids and their potential applications as mobile phase modifier and surface-bonded stationary phase in reversed-phase high performance liquid chromatography (RP-HPLC). Ionic liquids demonstrate advantages and potential in chromatographic field. PMID:19582220

  15. Application of Ionic Liquids in High Performance Reversed-Phase Chromatography

    Directory of Open Access Journals (Sweden)

    Wentao Bi

    2009-06-01

    Full Text Available Ionic liquids, considered “green” chemicals, are widely used in many areas of analytical chemistry due to their unique properties. Recently, ionic liquids have been used as a kind of novel additive in separation and combined with silica to synthesize new stationary phase as separation media. This review will focus on the properties and mechanisms of ionic liquids and their potential applications as mobile phase modifier and surface-bonded stationary phase in reversed-phase high performance liquid chromatography (RP-HPLC. Ionic liquids demonstrate advantages and potential in chromatographic field.

  16. A Method for the Quantitation of Trace Levels of Dimethyl Sulfoxide in Urine by High Performance Liquid Chromatography

    Science.gov (United States)

    1989-05-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY by...for the sample cleanup and concentration, followed by separation by reversed phase high performance liquid chromatography . EXPERIMENTAL Materials...DIMETHYL SULFOXIDE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY 4. AUTHORS (Last name, first name, middle initial. If military, show rank, e.g.

  17. Determination of Dimethyl Sulfoxide (DMSO), Ethanol (ETOH), Formamide (F) and Glycerol/Formal (GF) by High Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    1989-01-30

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC...Classification) (U) Determination of Dimethyl Sulfoxide (DMSO), Ethanol, (ETOH), Formamide (F), and Glycerol/ Formal (GF) by High Performance Liquid Chromatography (HPLC...and 5). High performance liquid chromatography (HPLC) was the analytical method of choice for analyzing DMSO, ethanol, formamide and

  18. Determination of 5-Bromo-2’-Deoxyuridine (BrdU) in Well Water by High Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    1992-09-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC...Securrty Classification) Determination of 5-Bromo-2’-Deoxyuridine (BrdU) in Well Water by High Performance Liquid Chromatography (hPLC) 12. PERSONAL...PLOT OF BrdU STABILITY VERSUS TIME ....................... 10 ii DETERMINATION OF 5-BROMO-2’-DEOXY-URIDINE (BrdU) IN WELL WATER BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

  19. Quality evaluation of moluodan concentrated pill using high-performance liquid chromatography fingerprinting coupled with chemometrics.

    Science.gov (United States)

    Tao, Lingyan; Zhang, Qing; Wu, Yongjiang; Liu, Xuesong

    2016-12-01

    In this study, a fast and effective high-performance liquid chromatography method was developed to obtain a fingerprint chromatogram and quantitative analysis simultaneously of four indexes including gallic acid, chlorogenic acid, albiflorin and paeoniflorin of the traditional Chinese medicine Moluodan Concentrated Pill. The method was performed by using a Waters X-bridge C18 reversed phase column on an Agilent 1200S high-performance liquid chromatography system coupled with diode array detection. The mobile phase of the high-performance liquid chromatography method was composed of 20 mmol/L phosphate solution and acetonitrile with a 1 mL/min eluent velocity, under a detection temperature of 30°C and a UV detection wavelength of 254 nm. After the methodology validation, 16 batches of Moluodan Concentrated Pill were analyzed by this high-performance liquid chromatography method and both qualitative and quantitative evaluation results were achieved by similarity analysis, principal component analysis and hierarchical cluster analysis. The results of these three chemometrics were in good agreement and all indicated that batch 10 and batch 16 showed significant differences with the other 14 batches. This suggested that the developed high-performance liquid chromatography method could be applied in the quality evaluation of Moluodan Concentrated Pill.

  20. DETERMINATION OF CARBENDAZIM IN WATER BY HIGH-PERFORMANCE IMMUNOAFFINITY CHROMATOGRAPHY ON-LINE WITH HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH DIODE-ARRAY OR MASS SPECTROMETRIC DETECTION

    Science.gov (United States)

    An automated method for the determination of carbendazim in water that combines high-performance immunoaffinity chromatography (HPIAC), high-performance liquid chromatography (HPLC) in the reversed-phase mode, and detection by either UV-Vis diode array detector (DAD) spectroscopy...

  1. High-performance liquid chromatography analysis methods developed for quantifying enzymatic esterification of flavonoids in ionic liquids

    DEFF Research Database (Denmark)

    Lue, Bena-Marie; Guo, Zheng; Xu, X.B.

    2008-01-01

    Methods using reversed-phase high-performance liquid chromatography (RP-HPLC) with ELSD were investigated to quantify enzymatic reactions of flavonoids with fatty acids in the presence of diverse room temperature ionic liquids (RTILs). A buffered salt (preferably triethylamine-acetate) was found ...

  2. Monitoring stevioside in soju by high-performance liquid chromatography and liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Ni, Fan; Ammann, Jeffrey; Mabud, Abdul

    2007-01-01

    A method using high-performance liquid chromatography (HPLC) with UV absorption detection was developed to monitor stevioside in soju, a distilled spirits product that is commercially available. The method uses a single-step dilution for sample preparation. It completely eliminates the time-consuming process of solid-phase extraction. A method using HPLC/mass spectrometry was optimized to confirm the identities of stevioside and other related impurities, including rebaudioside A, rebaudioside C, and dulcoside. The method was validated. The validation parameters included range (10.1-1007.3 ppm), precision, linearity, accuracy, robustness, system suitability, and intermediate precision. Stevioside standard solutions at 6 concentration levels were prepared for the validation work, including the tests for precision, linearity, and accuracy. The solutions were prepared in triplicate for each concentration. The relative standard deviation for the precision test was 0.999. The average recovery ranged from 95.7 to 101.1% for the soju samples spiked with stevioside standard. The detection limit for stevioside was estimated at 75 ppb. The method was used to screen several soju samples; no detectable stevioside was found in the samples.

  3. High-performance liquid chromatography of oligoguanylates at high pH

    Science.gov (United States)

    Stribling, R.; Deamer, D. (Principal Investigator)

    1991-01-01

    Because of the stable self-structures formed by oligomers of guanosine, standard high-performance liquid chromatography techniques for oligonucleotide fractionation are not applicable. Previously, oligoguanylate separations have been carried out at pH 12 using RPC-5 as the packing material. While RPC-5 provides excellent separations, there are several limitations, including the lack of a commercially available source. This report describes a new anion-exchange high-performance liquid chromatography method using HEMA-IEC BIO Q, which successfully separates different forms of the guanosine monomer as well as longer oligoguanylates. The reproducibility and stability at high pH suggests a versatile role for this material.

  4. DETERMINATION OF ENZYME-ACTIVITY BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

    NARCIS (Netherlands)

    WELLING, GW; SCHEFFER, AJ; WELLINGWESTER, S

    1994-01-01

    The application of high-performance liquid chromatography (HPLC) in the study of enzymatic reactions is reviewed. The rationale for using HPLC is given and whether the components of the reaction mixture should be derivatized prior to or after HPLC. An alphabetical list of enzymes assayed by HPLC is

  5. High-performance liquid chromatography of rat and mouse islet polypeptides

    DEFF Research Database (Denmark)

    Linde, S; Hansen, B; Welinder, B S

    1990-01-01

    After preparative high-performance liquid chromatography of mouse islet culture medium, concentrated on disposable C18 cartridges (Sep-Pak), an unexpected insulin immunoreactive peak eluting earlier than mouse insulin I and II was detected. Molecular mass determination by mass spectrometry...

  6. Going Beyond, Going Further: An Inexpensive Experiment for the Introduction of High Performance Liquid Chromatography.

    Science.gov (United States)

    Bidlingmeyer, Brian A.; Warren, F. Vincent, Jr.

    1984-01-01

    Background information, materials needed, laboratory procedures, and typical results are provided for five high performance liquid chromatography experiments (three isocratic and two step gradient separations). Suggestions for further experimentation are also provided, including quantitative determinations and separation of charged solutes. (JN)

  7. Extraction and Purification of Glucoraphanin by Preparative High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Lee, Iris; Boyce, Mary C.

    2011-01-01

    A student activity that focuses on the isolation of glucoraphanin from broccoli using preparative high-performance liquid chromatography (HPLC) is presented here. Glucoraphanin is a glucosinolate, whose byproducts are known to possess anticancer properties. It is present naturally at high levels in broccoli and other "Brassica" vegetables. This…

  8. High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory

    Science.gov (United States)

    Frey, Douglas D.; Guo, Hui; Karnik, Nikhila

    2013-01-01

    This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…

  9. DETERMINATION OF CHLOROPHENOLS, NITROPHENOLS, AND METHYLPHENOLS IN GROUND-WATER SAMPLES USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Science.gov (United States)

    A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...

  10. Determination of low molecular weight thiols using monobromobimane fluorescent labeling and high-performance liquid chromatography

    Science.gov (United States)

    Fahey, Robert C.; Newton, Gerald L.

    1988-01-01

    Methods are described for the preparation and high-performance liquid chromatography (HPLC) analysis of monobromobimane derivatives of low molecular weight thiols in extracts of biological samples. Typical problems encountered in the development and application of these methods are discussed. Analysis of mung bean extract is used as an example.

  11. Sugar Determination in Foods with a Radially Compressed High Performance Liquid Chromatography Column.

    Science.gov (United States)

    Ondrus, Martin G.; And Others

    1983-01-01

    Advocates use of Waters Associates Radial Compression Separation System for high performance liquid chromatography. Discusses instrumentation and reagents, outlining procedure for analyzing various foods and discussing typical student data. Points out potential problems due to impurities and pump seal life. Suggests use of ribose as internal…

  12. Experimental hydrophobicity parameters of perfluorinated alkylated substances from reversed-phase high performance liquid chromatography

    NARCIS (Netherlands)

    de Voogt, P.; Zurano, L.; Serné, P.; Haftka, J.J.H.

    2012-01-01

    Capacity factors of perfluorinated alkylated substances were obtained from isocratic reversed-phase high-performance liquid chromatography-mass spectrometry experiments at different organic modifier strengths of the mobile phase. The resulting capacity factor v. modifier strengths plots were extrapo

  13. Determination of rafoxanide and closantel in ovine plasma by high performance liquid chromatography.

    Science.gov (United States)

    Benchaoui, H A; McKellar, Q A

    1993-01-01

    A high performance liquid chromatographic method has been developed for the determination of rafoxanide and closantel in ovine plasma. Acetonitrile and chloroform were used for the extraction. The mean recoveries were 78.69% and 80.59% for rafoxanide and closantel, respectively. This method was applied to the characterization of rafoxanide plasma kinetics following oral administration of therapeutic doses to sheep.

  14. Comparison of high performance liquid chromatography and enzymatic analysis of soluble carbohydrates in loblolly pine

    Science.gov (United States)

    Patricia L. Faulkner; Michele M. Schoeneberger; Kim H. Ludovici

    1993-01-01

    Foliar tissue was collected from a field study designed to test impacts of atmospheric pollutants on loblolIy pine (Pinus taeda L.) seedlings. Standard enzymatic (ENZ) and high performance liquid chromatography (HPLC) methods were used to analyze the tissue for soluble sugars. A comparison of the methods revealed no significant diffennces in accuracy...

  15. New methods and materials for solid phase extraction and high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Dumont, Philip John [Iowa State Univ., Ames, IA (United States)

    1996-04-23

    This paper describes methods for solid phase extraction and high performance liquid chromatography (HPLC). The following are described: Effects of Resin Sulfonation on the Retention of Polar Organic Compounds in Solid Phase Extraction; Ion-Chromatographic Separation of Alkali Metals In Non-Aqueous Solvents; Cation-Exchange Chromatography in Non-Aqueous Solvents; and Silicalite As a Stationary Phase For HPLC.

  16. An Advanced, Interactive, High-Performance Liquid Chromatography Simulator and Instructor Resources

    Science.gov (United States)

    Boswell, Paul G.; Stoll, Dwight R.; Carr, Peter W.; Nagel, Megan L.; Vitha, Mark F.; Mabbott, Gary A.

    2013-01-01

    High-performance liquid chromatography (HPLC) simulation software has long been recognized as an effective educational tool, yet many of the existing HPLC simulators are either too expensive, outdated, or lack many important features necessary to make them widely useful for educational purposes. Here, a free, open-source HPLC simulator is…

  17. Quantification of six bioactive compounds in Zhenqi Fuzheng preparation by high-performance liquid chromatography couple

    Institute of Scientific and Technical Information of China (English)

    Yi-Kai Shi; Fang Cui; Fang-Di Hu; Ying-Yan Bi; Yu-Feng Ma; Shi-Lan Feng

    2011-01-01

    A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The

  18. High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory

    Science.gov (United States)

    Frey, Douglas D.; Guo, Hui; Karnik, Nikhila

    2013-01-01

    This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…

  19. An on-line high performance liquid chromatography-crocin bleaching assay for detection of antioxidants

    NARCIS (Netherlands)

    Bountagkidou, O.; Klift, van der E.J.C.; Tsimidou, M.Z.; Ordoudi, S.A.; Beek, van T.A.

    2012-01-01

    An on-line HPLC (high performance liquid chromatography) method for the rapid screening of individual antioxidants in mixtures was developed using crocin as a substrate (i.e. oxidation probe) and 2,2'-azobis(2-amidinopropane dihydrochloride (AAPH)) in phosphate buffer (pH 7.5) as a radical generator

  20. High Performance Liquid Chromatographic Analysis of Phytoplankton Pigments Using a C16-Amide Column

    Science.gov (United States)

    A reverse-phase high performance liquid chromatographic (RP-HPLC) method was developed to analyze in a single run, most polar and non-polar chlorophylls and carotenoids from marine phytoplankton. The method is based on a RP-C16-Amide column and a ternary gradient system consistin...

  1. Extraction and Purification of Glucoraphanin by Preparative High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Lee, Iris; Boyce, Mary C.

    2011-01-01

    A student activity that focuses on the isolation of glucoraphanin from broccoli using preparative high-performance liquid chromatography (HPLC) is presented here. Glucoraphanin is a glucosinolate, whose byproducts are known to possess anticancer properties. It is present naturally at high levels in broccoli and other "Brassica" vegetables. This…

  2. Determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    Science.gov (United States)

    Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: alachlor ethanesulfonic acid (ESA); alachlor oxanilic acid; acetochlor ESA; acetochlor oxanilic acid; metolachlor ESA; and metolachlor oxanilic acid. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The average HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.5 and 2.0 ??g/l ranged from 84 to 112%, with relative standard deviations of 18% or less. The average HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.2 and 2.0 ??g/l ranged from 81 to 118%, with relative standard deviations of 20% or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 ??g/l, whereas the LOQ using the HPLC/MS method was at 0.05 ??g/l. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water. Copyright (C) 2000 Elsevier Science B.V.

  3. Chemical fingerprint of Ganmaoling granule by double-wavelength ultra high performance liquid chromatography and ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Lou, Qiong; Ye, Xiaolan; Zhou, Yingyi; Li, Hua; Song, Fenyun

    2015-06-01

    A method incorporating double-wavelength ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry was developed for the investigation of the chemical fingerprint of Ganmaoling granule. The chromatographic separations were performed on an ACQUITY UPLC HSS C18 column (2.1 × 50 mm, 1.8 μm) at 30°C using gradient elution with water/formic acid (1%) and acetonitrile at a flow rate of 0.4 mL/min. A total of 11 chemical constituents of Ganmaoling granule were identified from their molecular weight, UV spectra, tandem mass spectrometry data, and retention behavior by comparing the results with those of the reference standards or literature. And 25 peaks were selected as the common peaks for fingerprint analysis to evaluate the similarities among 25 batches of Ganmaoling granule. The results of principal component analysis and orthogonal projection to latent structures discriminant analysis showed that the important chemical markers that could distinguish the different batches were revealed as 4,5-di-O-caffeoylquinic acid, 3,5-di-O-caffeoylquinic acid, and 4-O-caffeoylquinic acid. This is the first report of the ultra high performance liquid chromatography chemical fingerprint and component identification of Ganmaoling granule, which could lay a foundation for further studies of Ganmaoling granule.

  4. Salting-out assisted liquid-liquid extraction coupled to dispersive liquid-liquid microextraction for the determination of chlorophenols in wine by high-performance liquid chromatography.

    Science.gov (United States)

    Fan, Yingying; Hu, Shibin; Liu, Shuhui

    2014-12-01

    A novel procedure of sample preparation combined with high-performance liquid chromatography with diode array detection is introduced for the analysis of highly chlorinated phenols (trichlorophenols, tetrachlorophenols, and pentachlorophenol) in wine. The main features of the proposed method are (i) low-toxicity diethyl carbonate as extraction solvent to selectively extract the analytes without matrix effect, (ii) the combination of salting-out assisted liquid-liquid extraction and dispersive liquid-liquid microextraction to achieve an enrichment factor of 334-361, and (iii) the extract is analyzed by high-performance liquid chromatography to avoid derivatization. Under the optimum conditions, correlation coefficients (r) were >0.997 for calibration curves in the range 1-80 ng/mL, detection limits and quantification limits ranged from 0.19 to 0.67 and 0.63 to 2.23 ng/mL, respectively, and relative standard deviation was wines, with recovery rates in the range 82-104%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Analysis of chlorpheniramine in human urine samples using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Mehdi Maham

    2014-09-01

    Full Text Available A simple and environmentally friendly microextraction technique was used for determination of chlorpheniramine (CPM, an antihistamine drug, in human urine samples using dispersive liquid-liquid microextraction (DLLME followed by high performance liquid chromatography with diode array detection (HPLC-DAD. In this extraction technique, an appropriate mixture of acetonitrile (disperser solvent and carbon tetrachloride (extraction solvent was rapidly injected into the urine sample containing the target analyte. Tiny droplets of extractant were formed and dispersed into the sample solution and then sedimented at the bottom of the conical test tube by centrifugation. Under optimal conditions, the calibration curve was linear in the range of 0.055-5.5 µg mL-1, with a detection limit of 16.5 ng mL-1. This proposed method was successfully applied to the analysis of real urine samples. Low consumption of toxic organic solvents, simplicity of operation, low cost and acceptable figures of merit are the main advantages of the proposed technique.

  6. Separation of Nitration By-Products in Commercial-Grade Trinitro-Toluene by High Performance Liquid Chromatography.

    Science.gov (United States)

    1982-06-01

    MRL-TN-464 SEPARATION OF NITRATION BY-PRODUCTS IN COMMERCIAL-GRADE TITR-TOLUENE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Peter J. Sanders ABSTRACT...UNCLASSIFIED TITLE SEPARATION OF NITRATION BY-PRODUCTS IN COMMERCIAL-GRADE TRXNITRO-TOLUENE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY AUTHOR(S...PRODUCTS IN COMMERCIAL-GRADE TRINITRO-TOLUENE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY 16 INTRODUCTION Fbr some time, a need has existed for the

  7. [Qualitative and quantitative analysis of the amino acids in Rhizoma Arisaematis by ultra high performance liquid chromatography-tandem mass spectrometry and high performance liquid chromatography].

    Science.gov (United States)

    Wang, Xing; Chi, Yumei; Kang, An

    2014-12-01

    A method for the identification and determination of the polar amino components without ultraviolet activity in traditional Chinese medicines was developed. With Rhizoma Arisaematis as the object of this study, using pre-column derivatization with phenyl isothiocyanate (PITC) as the derivatization reagent, compounds were separated and identified on a C18 column (100 mm x 2.1 mm, 3.5 µm) by ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). A total of 20 components, including 18 amino acids and 2 amine compounds were identified. Furthermore, after the optimization of the derivatization conditions, 15 amino acids were determined by high performance liquid chromatography (HPLC) on Diamonsil C18 column (250 mm x 4.6 mm, 5 µm), detected at 254 nm and gradiently eluted by acetonitrile and 0. 05 mol/L ammonium acetate-acetic acid (pH 6. 5) as the mobile phases. The results of methodological study demonstrated that the method can meet the requirements of the determination. All calibration curves expressed good linearity: Glu, Try in the range of 2-100 mg/L, Arg in the range of 6-300 mg/L, others in the range of 0. 8-40 µg/L, with the correlation coefficients ≥ 0. 999 5. The average recovery of this method was among 95%-105% and the RSD was less than 3%. The developed method was successfully applied to quantitative determination of amino compounds in 12 batches of Rhizoma Arisaematis samples. The method is simple, sensitive, accurate, and can be used for rapid identification and determination of amino components in traditional Chinese medicines.

  8. Mercury speciation in seawater by liquid chromatography-inductively coupled plasma-mass spectrometry following solid phase extraction pre-concentration by using an ionic imprinted polymer based on methyl-mercury-phenobarbital interaction.

    Science.gov (United States)

    Rodríguez-Reino, María Pilar; Rodríguez-Fernández, Roi; Peña-Vázquez, Elena; Domínguez-González, Raquel; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2015-04-24

    Trace levels of inorganic mercury, methyl-mercury and ethyl-mercury have been assessed in seawater by high performance liquid chromatography (HPLC) hyphenated with inductively coupled plasma-mass spectrometry (ICP-MS) after solid phase extraction (SPE) pre-concentration with a novel synthesized ionic imprinted polymer. The adsorbent material was prepared by trapping a non-vinylated chelating ligand (phenobarbital) via imprinting of a ternary mixed ligand complex of the non-vinylated chelating agent, the template (methyl-mercury), and the vinyl ligand (metacrylic acid, MAA). Ethylene dimetacrylate (EDMA) and 2,2'-azobisisobutyronitrile (AIBN) were used as cross-linker and initiator reagents, respectively; and the precipitation polymerization technique was used in a porogen of acetonitrile/water (4:1). The best retention properties for methyl-mercury, inorganic mercury and ethyl-mercury species from seawater were obtained when loading 200 mL of sample adjusted to pH 8.0 and at a flow rate of 2.0 mL min(-1) on a column-packed with 200mg of the material. Quantitative mercury species recoveries were obtained using 4 mL of an eluting solution consisting of 0.8% (v/v) 2-mercaptoethanol and 20% (v/v) methanol (pH adjusted to 4.5) pumped at a flow rate of 2.0 mL min(-1). Mercury species separation was achieved on a Kinetex C18 column working under isocratic conditions (0.4% (v/v) 2-mercaptoethanol, 10% (v/v) methanol, pH 2.5, flow rate 0.7 mL min(-1)). ICP-MS detection was performed by monitoring the mercury mass to charge ratio of 202. The limits of quantification of the method were 11, 6.7, and 12 ng L(-1), for inorganic mercury, methyl-mercury and ethyl-mercury, respectively (pre-concentration factor of 50); whereas, analytical recoveries ranged from 96 to 106%. The developed method was successfully applied to several seawater samples from unpolluted areas.

  9. Determination of acaricides in honey by high-performance liquid chromatography with photodiode array detection.

    Science.gov (United States)

    Martel, Anne-Claire; Zeggane, Sarah

    2002-04-19

    Rapid analytical methods are described to control quality of honeys, concerning residues of acaricides applied in hives to prevent Varroa jacobsoni infestation. A liquid-liquid extraction with hexane-propanol-2-ammonia (60 ml:30 ml:0.28%) was used for the simultaneous analysis of coumaphos, bromopropylate, amitraz and fluvalinate. For thymol, one clean up on a solid-phase extraction C18 (500 mg, 6 ml) column was performed; for rotenone, a liquid extraction with dichloromethane was realised. Quantitative recoveries obtained with honey were satisfactory and were superior to 80%. All acaricides are identified by reversed-phase high-performance liquid chromatography with photodiode array detection. Quantification limits obtained were below maximal residue limits when these exist.

  10. Ionic Liquids as Mobile Phase Additives for Separation of Nucleotides in High-Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    ZHANG,Wen-Zhu(张文珠); HE,Li-Jun(何丽君); LIU,Xia(刘霞); JIANG,Sheng-Xiang(蒋生祥)

    2004-01-01

    Ionic liquids are a type of salts that are liquid at low temperature (< 100 ℃). Because of their some special properties, they have been widely used as new "green solvents" for many chemical reactions and liquid-liquid extraction in the past several years. In this paper, a new method for the separation of nucleotides is developed and the essential feature of the method is that 1-alkyl-3-methylimidazolium salts are used as mobile phase additives, resulting in a baseline separation of nucleotides without need of gradient elution and need of organic solvent addition as currently used in RP-HPLC. This study shows the potential application of ionic liquids as mobile phase additives in reversed-phase liquid chromatography.

  11. Analyses of acute kidney injury biomarkers by ultra-high performance liquid chromatography with mass spectrometry.

    Science.gov (United States)

    Al Za'abi, Mohammed; Ali, Badreldin H; ALOthman, Zeid A; Ali, Imran

    2016-01-01

    The newly developed acute kidney injury biomarkers are very important for the early and timely detection of kidney diseases. This review contains details of the analyses of several acute kidney injury biomarkers using ultra-high performance liquid chromatography-mass spectrometry in urine and plasma samples. In this review we attempt to discuss some aspects of the types of the biomarkers, patents, sample preparation, and the analyses. Besides, efforts were also made to discuss the possible uses of superficially porous (core-shell) columns in traditional and inexpensive high-performance liquid chromatography instruments. Additionally, the challenges and the future prospects are also highlighted. The present review will be useful for the academicians, scientists, and clinicians for the early detection of acute kidney injury biomarkers.

  12. Homochiral metal-organic framework used as a stationary phase for high-performance liquid chromatography.

    Science.gov (United States)

    Kong, Jiao; Zhang, Mei; Duan, Ai-Hong; Zhang, Jun-Hui; Yang, Rui; Yuan, Li-Ming

    2015-02-01

    Metal-organic frameworks are promising porous materials. Chiral metal-organic frameworks have attracted considerable attention in controlling enantioselectivity. In this study, a homochiral metal-organic framework [Co(2) (D-cam)(2) (TMDPy)] (D-cam = D-camphorates, TMDPy = 4,4'-trimethylenedipyridine) with a non-interpenetrating primitive cubic net has been used as a chiral stationary phase in high-performance liquid chromatography. It has allowed the successful separation of six positional isomers and six chiral compounds. The good selectivity and baseline separation, or at least 60% valley separation, confirmed its excellent molecular recognition characteristics. The relative standard deviations for the retention time of run-to-run and column-to-column were less than 1.8 and 3.1%, respectively. These results demonstrate that [Co(2) (D-cam)(2) (TMDPy)] may represent a promising chiral stationary phase for use in high-performance liquid chromatography.

  13. Determination of Polysaccharide in Radix pseudostellariae Extract by Size-Exclusion High-Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A simple size-exclusion high-performance liquid chromatographic method was developed for rapid molecular mass screening to determine the average molecular mass, polydispersity, and quantity of Taizishen polysaccharides extract. The screening used a TOSOH TSK-GEL G3000SW high-performance liquid chromatographic column with 0.1 mol/L NaNO3 buffer as the mobile phase and refractive index detector. The molecular mass calibration curve was linear for polysaccharide standards from 10 to 100 kDa with a correlation coefficient of 0.9991. The method can be used to analyze the quantity, average molecular mass,and polydispersity of polysaccharides. In addition, the screening method is suitable for quality control of polysaccharide preparations in Chinese medicines and pharmaceutical products.

  14. Determination of fenbendazole, praziquantel and pyrantel pamoate in dog plasma by high-performance liquid chromatography.

    Science.gov (United States)

    Morovján, G; Csokán, P; Makranszki, L; Abdellah-Nagy, E A; Tóth, K

    1998-02-27

    Simple and rapid high-performance liquid chromatographic methods were developed for the determination of fenbendazole, praziquantel and pyrantel pamoate in dog plasma. The combination of these drugs is the most powerful treatment against most types of worms. Blood plasma samples obtained in a pharmacokinetic trial were prepared using solid-phase extraction. Fenbendazole and praziquantel were analyzed simultaneously by reversed-phase high-performance liquid chromatography on an octadecyl-modified silica stationary phase employing acetonitrile-phosphate buffer (pH 3.0) eluent and ultraviolet detection at 220 nm. Pyrantel was analyzed separately on a base-deactivated reversed-phase column using methanol-tetrahydrofuran-ammonium acetate buffer (pH 4.6) eluent and ultraviolet detection at 317 nm. Average recoveries for fenbendazole, praziquantel and pyrantel pamoate were 76.8, 93.4 and 90.5%, respectively. Limits of quantitation were in the range of 15-25 ng/ml plasma.

  15. Serum Protein Profile Study of Clinical Samples Using High Performance Liquid Chromatography-Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Karemore, Gopal Raghunath; Ukendt, Sujatha; Rai, Lavanya

    2009-01-01

    The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested for estab......The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested...... for establishing the ability of HPLC-LIF protein profiling technique for discrimination, using hard clustering and Fuzzy clustering methods. The clustering algorithms have quite successfully classified the profiles as belonging to normal, cancer of cervix, and oral cancer conditions....

  16. High Performance Liquid Chromatographic Method for Determination of Dipyridamole in Human Plasma

    Directory of Open Access Journals (Sweden)

    DAVOOD BEIGI BAND ARAB ADI

    1999-08-01

    Full Text Available A simple, rapid and specific high-performance liquid chromatographic procedure is reported for"nquantitative determination of dipyridamole in human -plasma. The assay uses a reversed-phase"nhigh-performance liquid chromatographic (HPLC and UV detection at 280nm and has a limit"nof detection of approximately 5ng/mL. The mobile phase consists of MeOH-H20 (60:40"nadjusted to pH 3.3. Dipyridamole was extracted from plasma by back-extraction procedure, with"npropranolol as the internal standard. The reproducibility of the method is satisfactory

  17. The Application of High Performance Liquid Chromatography in the Analysis of Trace Rare Earth

    Institute of Scientific and Technical Information of China (English)

    WANG; Xiu-feng; DING; You-qian

    2012-01-01

    <正>Rare earth elements are very important in the field of radioanalytical chemistry, for it must be separated and determined in the measurements of burn-up and fission yield. High performance liquid chromatography has become a main method in the separation of rare earth elements due to its obvious advantages, this is, high speed of analysis, high efficiency and easy automation. The ion exchange chromatography is the main means to separate rare earth elements, especially the cation exchange

  18. Determination of pentachlorophenol in water and aquifer sediments by high-performance liquid chromatography

    Science.gov (United States)

    Goerlitz, D.F.

    1981-01-01

    Methods for the determination of pentachlorophenol (PCP) in water and aquifer sediments are presented. Reverse-phase high-performance liquid chromotography employing ion suppression and gradient elution is used. PCP can be determined directly in water at a lower limit of detection Of 0.2 micrograms per liter. For extracts of sediment, PCP can be determined to a lower limit of 1.0 micrograms per kilogram.

  19. Resolution of the stereoisomers of baclofen by high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Weatherby, R.P.; Allan, R.D.; Johnston, G.A.R. (Sydney Univ. (Australia))

    1984-01-01

    The GABA analogue baclofen (3-(p-chlorophenyl)-4-aminobutanoic acid) has stereospecific actions on the peripheral and central nervous systems. This paper describes the resolution of tritium-labelled baclofen by high performance liquid chromatography on a reverse-phase C18 column using a chiral mobile phase. The method, which may have general application to certain other GABA analogues, affords optically pure (+)- and (-)-baclofen labelled with tritium to high specific activity suitable for ligand binding and other neurochemical studies.

  20. A simple high performance liquid chromatography method for determination of rebamipide in rat urine

    OpenAIRE

    Cooper, Dustin L.; Harirforoosh, Sam

    2014-01-01

    Rebamipide is a mucoprotective agent commonly used to prevent nonsteriodal anti-inflammatory drug-induced gastrointenstinal side effects [1]. Human plasma and urine analysis of rebamipide utilizing high performance liquid chromatography (HPLC) have been reported [2]. Recently, we reported on the plasma levels of rebamipide in presense or absence of celecoxib or diclofenac in rats [3] using a modified HPLC method of detection developed by Jeoung et al. [4]. To tailor the method towards use in ...

  1. Quality Evaluation of Potentilla fruticosa L. by High Performance Liquid Chromatography Fingerprinting Associated with Chemometric Methods

    OpenAIRE

    Wei Liu; Dongmei Wang; Jianjun Liu; Dengwu Li; Dongxue Yin

    2016-01-01

    The present study was performed to assess the quality of Potentilla fruticosa L. sampled from distinct regions of China using high performance liquid chromatography (HPLC) fingerprinting coupled with a suite of chemometric methods. For this quantitative analysis, the main active phytochemical compositions and the antioxidant activity in P. fruticosa were also investigated. Considering the high percentages and antioxidant activities of phytochemicals, P. fruticosa samples from Kangding, Sichua...

  2. [Comparison of refractometric and ultraviolet detection methods in lactulose assay by high performance liquid chromatography].

    Science.gov (United States)

    Vaccher, C; Berthelot, P; Flouquet, N; Debaert, M

    1990-01-01

    Dosage of lactulose and determination of related sugars (lactose, fructose, galactose, épilactose) were undertaken by high performance liquid chromatography (HPLC). The present note described two modes of detection used simultaneously and compared: refractive index detector (RI) and multiwavelength ultraviolet detector (UV). HPLC is performed with an aminopropylsylil phase as stationary phase and an isocratic mobile phase containing acetonitrile and aqueous sodium phosphate. The results are outlined and discussed.

  3. DETERMINATION OF PROTEINS FROM BUFFALO MILK USING HIGH PERFORMANCE LIQUID CROMATOGRAPHY RP-HPLC

    OpenAIRE

    AURELIA PECE; COROIAN C.; BIANCA GHIRILĂ; G. MURESAN; VIOARA MIRESAN

    2013-01-01

    In the hereby paper, we have undertaken a study on buffalo milk proteins, employing high performance liquid chromatography (HPLC). This RP-HPLC technique is commonly employed in the separation and assessment of caseins K, and in the fresh, as well as processed milk. These methods are also successfully applied in the authenticity and origin assessment of certain cheese products and the qualitative analysis of milk in bubalines, ovines, caprines and bovines (Ferreira si Cacote, 2003; Veloso si...

  4. Surface Confined Ionic Liquid-A New Stationary Phase for the Separation of Ephedrines in High-performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    Shu Juan LIU; Feng ZHOU; Xiao Hua XIAO; Liang ZHAO; Xia LIU; Sheng Xiang JIANG

    2004-01-01

    In this article, a new and effective stationary phase based on ionic liquid modified silica is first reported and used for the separation of ephedrines in high-performance liquid chromatography (HPLC). The separation results indicate the high efficiency and reproducibility of the stationary phase. The electrostatic interaction, ion-exchange interaction between the solutes and the stationary phase are considered to attribute the effective separation. Moreover, the free silanols on the surface of the silica are effectively masked by the immobilized ionic liquid, a result of which is to decrease the non-specific absorption.

  5. Isolation and purification of heroin from heroin street samples by preparative high performance liquid chromatography.

    Science.gov (United States)

    Guo, Zhen; Zheng, Hui; Lu, Yanzhen; Wei, Yun

    2012-09-10

    The present study established a novel method using preparative high performance liquid chromatography to isolate and purify heroin·HCl from heroin street samples to be used as a reference standard. Different kinds of mobile phases and columns were used, ultimately the mobile phase consisting of hexane-isopropanol-methanol (65:28:7, v/v) and the SIL preparative column prepared in laboratory were selected as the final condition. Heroin was further purified by the drowning-out crystallization method using isopropanol-methanol (50:1, v/v) and hexane as drowning-out anti-solvents and salting-out agents, respectively. The purity was assessed by analytical high performance liquid chromatography and the confirmation of the chemical structure was performed by IR and NMR. About 110.7mg of heroin·HCl at a purity of over 99.52% was obtained from 180mg of heroin street samples which contained 156.15mg of heroin·HCl component by preparative high performance liquid chromatography. This method is suitable for preparing heroin standards in forensic science area.

  6. Determination of five antiarrhythmic drugs in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Jouyban, Abolghasem; Sorouraddin, Mohammad Hossein; Farajzadeh, Mir Ali; Somi, Mohammad Hossein; Fazeli-Bakhtiyari, Rana

    2015-03-01

    A fast and sensitive high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detection was developed and validated for the simultaneous quantitation of five antiarrhythmic drugs (metoprolol, propranolol, carvedilol, diltiazem, and verapamil) in human plasma samples. It involves dispersive liquid-liquid microextraction (DLLME) of the desired drugs from 660 µL plasma and separation using isocratic elution with UV detection at 200 nm. The complete separation of all analytes was achieved within 7 min. Acetonitrile (as disperser solvent) resulting from the protein precipitation procedure was mixed with 100 µL dichloromethane (as an extraction solvent) and rapidly injected into 5 mL aqueous solution (pH 11.5) containing 1% (w/v), NaCl. After centrifugation, the sedimented phase containing enriched analytes was collected and evaporated to dryness. The residue was re-dissolved in 50 µL de-ionized water (acidified to pH 3) and injected into the HPLC system for analysis. Under the optimal conditions, the enrichment factors and extraction recoveries ranged between 4.4-10.8 and 33-82%, respectively. The suggested method was linear (r(2) ≥0.997) over a dynamic range of 0.02-0.80 µg mL(-1) in plasma. The intra- and inter-days relative standard deviation (RSD%) and relative error (RE%) values of the method were below 20%, which shows good precision and accuracy. Finally, this method was applied to the analysis of real plasma samples obtained from the patients treated with these drugs.

  7. Analysis of drugs of abuse in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Fernández, P; Regenjo, M; Bermejo, A M; Fernández, A M; Lorenzo, R A; Carro, A M

    2015-04-01

    Opioids and cocaine are widely used at present, both for recreational purposes and as drugs of abuse. This raises the need to develop new analytical methods specifically designed for the simultaneous detection of several drugs of abuse in biological samples. In this work, dispersive liquid-liquid microextraction (DLLME) was assessed as a new sample treatment for the simultaneous extraction of morphine (MOR), 6-acetylmorphine (6AM), cocaine (COC), benzoylecgonine (BZE) and methadone (MET) from human plasma. Preliminary assays were done before developing an experimental design based on a Uniform Network Doehlert which allowed the optimum extraction conditions to be identified, namely: a volume of extractant solvent (chloroform) and dispersant solvent (acetonitrile) of 220 µl and 3.2 ml, respectively; 0.2 g of NaCl as a salting-out additive; pH 10.6 and ultrasound stirring for 3.5 min. The resulting extracts were analyzed by high-performance liquid chromatography with photodiode array detection (HPLC-PDA), using an XBridge® RP18 column (250 × 4.6 mm i.d., 5 µm particle size). Calibration graphs were linear over the concentration range 0.1-10 µg ml⁻¹, and detection limits ranged from 13.9 to 28.5 ng ml⁻¹. Precision calculated at three different concentration levels in plasma was included in the range 0.1-6.8% RSD. Recoveries of the five drugs were all higher than 84% on average. Finally the proposed method was successfully applied to 22 plasma samples from heroin, cocaine and/or methadone users, and the most frequently detected drug was benzoylecgonine, followed by methadone, cocaine and morphine.

  8. Preliminary Validation of High Performance Liquid Chromatography Method for Detection of Methyltestosterone Residue in Carp Muscle

    Institute of Scientific and Technical Information of China (English)

    JIANG Jie; LIN Hong; FU Xiaoting; LI Mingming

    2005-01-01

    The use of synthetic anabolic steroid methyltestosterone (MT) as growth promoter is prohibited in China. Validations of analytical methods for MT residue in food and the results obtained have become indispensable. The high performance liquid chromatography (HPLC) method for the detection of MT with liquid-liquid extraction by trichloromethanemethanol in carp muscle tissue was preliminarily validated with reference to the following parameters: recovery (accuracy)at the 1, 5 and 10 mgkg-1 level, between-run and within-run CV values (repeatability, also called relative standard deviation(RSD)) and limit of detection. The recoveries were above 80% and the between-run and within-run CV values below 10%for muscle tissue. The limit of detection was 0.05 mgkg-1.

  9. Analysis of nitroguanidine in Aqueous Solutions by HPLC (High Performance Liquid Chromatography) with electrochemical Detection and Voltammetry

    Science.gov (United States)

    1987-04-01

    The nitroguanidine was analyzed by high performance liquid chromatography (HPLC) with electrochemical detection at a hanging miercury drop electrode...previously reported on the application of solid sorbent collection techniques to the analysis of several explosives in water by high performance liquid chromatography (HPLC

  10. Specific determination of selenoaminoacids in whole milk by 2D size-exclusion-ion-paring reversed phase high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP MS)

    Energy Technology Data Exchange (ETDEWEB)

    Bierla, Katarzyna [Laboratoire de Chimie Analytique Bio-Inorganique et Environnement, CNRS UMR5254, Helioparc, 2, av. Pr. Angot, 64053 Pau (France)], E-mail: katarzyabierla@wp.pl; Szpunar, Joanna [Laboratoire de Chimie Analytique Bio-Inorganique et Environnement, CNRS UMR5254, Helioparc, 2, av. Pr. Angot, 64053 Pau (France); Lobinski, Ryszard [Laboratoire de Chimie Analytique Bio-Inorganique et Environnement, CNRS UMR5254, Helioparc, 2, av. Pr. Angot, 64053 Pau (France); Warsaw Technical University, Department of Analytical Chemistry, Noakowskiego 3, 00-664 Warsaw (Poland)

    2008-08-29

    A procedure was developed for the quantitative recovery of selenomethionine (SeMet) and selenocysteine (SeCys) from whole milk. It was based on the protein unfolding, carbamidomethylation of the aminoacid residues using iodoacetamide and proteolysis using Protease XIV. The selenoaminoacids were specifically determined by ion-paring reversed phase HPLC-ICP MS after their isolation from the post-reaction mixture by size-exclusion LC. Se(IV) present in the sample was derivatized as well and was determined along with the selenoaminoacids. The origin and identity of species were identified by the co-elution with the Se(IV), isotopically labelled selenomethionine, and with the synthetic standard of carbamidomethylated selenocysteine. The method development for SeCys was assisted by using glutathione peroxidise as the SeCys standard. SeMet, SeCys and Se(IV) were quantified by the method of standard additions. The mass balance provided a measure of the method validation. The method was applied to monitoring selenium speciation during supplementation of cows (dose-effect study) with Se-rich yeast containing feed and during milk processing.

  11. Optimization of an anion-exchange high performance liquid chromatography-inductively coupled plasma-mass spectrometric method for the speciation analysis of oxyanion-forming metals and metalloids in leachates from cement-based materials.

    Science.gov (United States)

    Mulugeta, Mesay; Wibetoe, Grethe; Engelsen, Christian J; Lund, Walter

    2010-10-01

    A method was developed for the speciation analysis of the oxyanions of As(III), As(V), Cr(VI), Mo(VI), Sb(III), Sb(V), Se(IV), Se(VI) and V(V) in leachates from cement-based materials, based on anion-exchange HPLC coupled with ICP-MS. The method was optimized in a two-step multivariate approach: the effect of sample pH and mobile phase composition on resolution, peak symmetry and analysis time was studied. Optimum conditions were then identified for the significant experimental factors by studying their interdependence. A mobile phase composition of 20 mM ammonium nitrate, 50 mM ammonium tartrate and pH 9.5 was found to be a compromise optimum for the separation of the target analytes using isocratic elution. The optimum condition provided separation of the analytes in less than 6 min, at a mobile phase flow rate of 1.0 mL/min. The signal intensities of the analytes were improved by adding 1% methanol to the mobile phase. The limit of detection of the method was in the range 0.2-2.2 μg/L for the various species. The effect of sample constituents was studied using spiked concrete leachates. The method was used to determine the target oxyanionic species in leachates generated from a concrete material in the pH range 3.5-12.4; CrO(4)(2-), MoO(4)(2-) and VO(4)(3-) were detected in most of the leachates.

  12. Report on three aliphatic dimethylarsinoyl compounds as common minor constituents in marine samples. An investigation using high-performance liquid chromatography inductively coupled plasma mass spectrometry and electrospray ionisation tandem mass spectrometry

    DEFF Research Database (Denmark)

    Sloth, Jens Jørgen; Larsen, Erik Huusfeldt; Julshamn, K.

    2005-01-01

    for the structures of the three compounds. The concentrations of the three arsenicals were determined in 37 marine organisms comprising algae, crustaceans, bivalves, fish and mammals by HPLC/ICPMS. The three arsenicals DMAA, DMAE and DMAP, which occurred at mug kg(-1) concentrations, were detected in 25, 23 and 17...

  13. High-Performance Liquid Chromatography Determination of Meloxicam and Piroxicam with Ultraviolet Detection

    Directory of Open Access Journals (Sweden)

    Sherry Cox

    2014-01-01

    Full Text Available A simple accurate and sensitive high-performance liquid chromatographic method for the determination of meloxicam and piroxicam concentrations in small volume plasma samples has been developed. Following a liquid extraction using chloroform, samples were separated by reversed-phase high-performance liquid chromatography on an XBridge C18 column (4.6 × 250 mm and quantified using ultraviolet detection at 360 nm. The mobile phase was a mixture of water with glacial acetic acid (pH 3.0 and acetonitrile (50 : 50, with a flow rate of 1.0 mL/min. The standard curve ranged from 5 to 10,000 ng/mL for meloxicam in bearded dragon (Pogona vitticeps plasma and piroxicam in crane (Grus rubicunda plasma. Intra- and interassay variability for meloxicam and piroxicam were less than 10% and the average recovery was greater than 90% for both drugs. This method was developed in bearded dragon and crane plasma and should be applicable to any species, making it useful for those investigators dealing with small sample volumes, particularly when conducting pharmacokinetics studies which require multiple sampling from the same animal.

  14. Analysis of ganciclovir and its related substances using high performance liquid chromatography and liquid chromatography-mass spectrometry methods

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all r...

  15. Quantification of Quercetin and Rutin from Benincasa hispida Seeds and Carissa Congesta Roots by High-performance Thin Layer Chromatography and High-performance Liquid Chromatography.

    Science.gov (United States)

    Doshi, Gaurav Mahesh; Une, Hemant Devidas

    2016-01-01

    In Indian Ayurvedic system, Benincasa hispida (BH) and Carissa congesta (CC) are well-known plants used for major and minor ailments. BH has been regarded as Kushmanda, whereas CC has been used in immune-related disorders of the human system. Quercetin and rutin identified from the vast plethora of plant extracts have proved to possess ethnopharmacological relevance. In present studies, we have determined quercetin and rutin in terms of percentage in BH seeds and CC roots by high-performance thin layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC). After extraction and phytochemical screening, the extracts were subjected to quantification for the presence of quercetin and rutin by HPTLC and HPLC. HPTLC showed quercetin as 44.60, 27.13% and rutin as 32.00, 36.31% w/w, whereas HPLC revealed quercetin as 34.00, 35.00% and rutin as 21.99, 45.03% w/v in BH and CC extracts, respectively. The BH and CC extracts have elucidated peaks that were corresponding with standard peaks on undertaking chromatographic studies. Quercetin and rutin are isolated from BH seeds and CC roots by High Performance. Thin Layer Chromatography and High Performance Liquid Chromatography. HPTLC revealed presence of quercetin as 44.60, 27.13 % and rutin as 32.00, 36.31 % w/w. HPLC revealed presence of quercetin as 34.00, 35.00 % and rutin as 21.99, 45.03 % w/v. Abbreviation Used: HPTLC: High Performance Thin Layer Chromatography; HPLC: High Pressure Liquid Chromatography, UV: Ultraviolet, CC: Carissa congesta, BH: Benincasa hispida.

  16. On-line radiochemical assay for monoamine oxidase utilizing high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Nissinen, E.; Linko-Loeppoenen SMae; Maennistoe P4

    1984-12-01

    A fast and sensitive assay for the determination of monoamine oxidase activity was developed. The method is based on the separation and quantitation of /sup 14/C-labeled assay products by high-performance liquid chromatography, which is interfaced directly into a flow-through radioactivity detector. This allows on-line quantitation of the radioactive compounds with picomole sensitivity. The method makes possible the complete separation and detection of the deaminated products of monoamine oxidase A and B substrates benzylamine and 5-hydroxytryptamine, respectively. This assay has been applied to the measurement of monoamine oxidase A and B activities in rat brain.

  17. Determination of 1-hydroxypyrene in human urine by high-performance liquid chromatography

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Poulsen, O M; Christensen, J M

    1993-01-01

    A high-performance liquid chromatography (HPLC)/fluorescence method for quantitative analysis of 1-hydroxypyrene in urine was developed. The method validation analysis showed the method to be in analytical control. No significant systematical errors could be demonstrated. The entire run time...... of chromatography was 10 min using isocratic elution (acetonitrile-water, 70:30), and the retention time for 1-hydroxypyrene was 3.5 min. The short run time in combination with the low limit detection (1.37 nmol/L) makes the method potentially applicable for surveillance of pyrene exposure in work environments...

  18. Determination of Constituents in Hair Dyes by Reversed-phase High-Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A reversed-phase high-performance liquid chromatographic method for the separation and quantitation of 1,4-phenylenediamine, 4-aminophenol, 3-aminophenol, 1,3-benzendiol and 2,6-phenylenediamine in hair dyes was developed. The separation was carried out on a μ-Bondapak C18 column with methanol-water containing 0.1% triethylamine and 0.02 mol/L NH4Ac (pH=5.20) (10:90, vol./vol.) as the mobile phase. Two real samples were analyzed.

  19. Determination of enantiomeric impurity of etomidate by high performance liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective To determine enantiomeric impurity of etomidate using high performance liquid chromatography. Methods (R)-etomidate and (S)-etomidate were separated on a CHIRALPAK AD-H column. The mobile phase consisted of 20∶80(v/v) isopropanol-n-hexane. The flow rate of the mobile phase was 0.5mL/min. The detected wavelength was 242nm. Results (R)-etomidate and (S)-etomidate could be separated completely under these conditions. The precision of (R)-etomidate was 1.57% (n=3). The limit of detection of (R)-etomid...

  20. Anomalous properties of flavonoids in reversed phase high performance liquid chromatography

    Science.gov (United States)

    Zenkevich, I. G.; Gushchina, S. V.

    2011-09-01

    It is shown through reversed phase high performance liquid chromatography that a characteristic feature of such abundant natural flavonoids as flavon-3-ols is an anomalously strong antibate dependence of their retention indices ( RI) on the organic solvent concentration ( C) in the eluent, dRI/ dC < 0. In order to interpret this anomaly, the specific optical rotation values [α]{D/20} of natural (+)-(2 R,3 R)-dihydroquercetin in different solvents are compared, confirming the reverse formation of hydrated flavonoids in aqueous solutions.

  1. Study of Saiga Horn Using High-Performance Liquid Chromatography with Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Kateřina Mikulíková

    2012-01-01

    Full Text Available The saiga horns have been investigated the using of modern analytic methods. High-performance liquid chromatography (HPLC with mass-spectrometric (MS and MS/MS detection and polyacrylamide gel electrophoresis (PAGE were used. It could be concluded that basic proteins of the saiga horns are keratins and collagen. The basic representation protein in all samples is keratin type I microfibrillar (from sheep, keratin type II microfibrillar (from sheep, collagen type I (α1 (from bovine and collagen type I (α2 (from bovine. Free amino acids we determined in all samples are nontreated by enzyme.

  2. Quantitative high-performance liquid chromatographic determination of delta 4-3-ketosteroids in adrenocortical extracts.

    Science.gov (United States)

    Ballerini, R; Chinol, M; Ghelardoni, M

    1980-05-30

    A high-performance liquid chromatographic method is described for the determination of seven steroids in adrenocortical extracts showing a delta 4-3-ketonic conjugated system. The seven steroids (cortisol, cortisone, 11-dehydrocorticosterone, corticosterone, 11-deoxycortisol, aldosterone and 11-deoxycorticosterone) were separated with a chloroform-methanol gradient on a 5-micron silica column and with a water-acetonitrile gradient on a 10-micron RP-8 column. Effluents were monitored by UV absorption at 242 nm. Quantitative analysis was performed by comparing peak areas, which are proportional to the amounts of the individual substances (external standard method). The method is rapid, sensitive, easy to perform and reproducible.

  3. Determination of cortisol and cortisone in urine using high-performance liquid chromatography with UV detection.

    Science.gov (United States)

    Jenner, D A; Richards, J

    1985-01-01

    The application of reversed-phase gradient high-performance liquid chromatography with UV detection to the determination of cortisol and cortisone in 24-h urine samples is described. The method employs Sep-pak C18 cartridges for the part-purification and concentration of the corticosteroids, with sample enrichment at the head of an HPLC pre-column and separation using water/acetonitrile gradient. The internal standard is 6alpha-methylprednisolone. Measurement of both cortisone and cortisol provides further information on adrenocortical function. 24-hour excretion rate data from normal subjects are reported.

  4. Determination of rhoifolin and daidzin in human plasma by high-performance liquid chromatography.

    Science.gov (United States)

    Ishii, K; Urano, S; Furuta, T; Kasuya, Y

    1994-05-13

    A method for determining flavonoids in human plasma is presented for application to pharmacokinetic studies of two flavonoids, rhoifolin and daidzin. Isocratic reversed-phase high-performance liquid chromatography (HPLC) was used with genistin as an internal standard and solid-phase extraction using a Sep-Pak C18 cartridge. The mobile phases were acetonitrile-0.1 M ammonium acetate solution (20:80, v/v) for rhoifolin and methanol-0.1 M ammonium acetate solution (33:67, v/v) for daidzin. The detection limits on-column were 2 ng for rhoifolin and 0.5 ng for daidzin.

  5. Rapid determination of succinylcholine in human plasma by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Lagerwerf, A J; Vanlinthout, L E; Vree, T B

    1991-10-04

    A high-performance liquid chromatographic method with fluorometric detection has been developed for the determination of succinylcholine in human plasma. Succinylcholine shows fluorescence at 282 nm with an excitation at 257 nm. The assay is sensitive, reproducible and linear for concentrations ranging from 100 ng/ml to 100 micrograms/ml of succinylcholine. In a pilot study the plasma concentration-time curve showed a triphasic elimination, with half-lives of 0.4, 1.2 and 8 min, respectively. In a clinical setting, drugs commonly administered during anaesthesia did not interfere with the assay. This method provides a simple and time-saving alternative to existing methods.

  6. Determination of contents of 10-Hydroxycamptothecin in Camptotheca acuminata by high-performance liquid chromatogram

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The determination method of 10-hydroxycamptothecin in Camptotheca acuminata fruits by high-performance liquid chromatogram (HPLC) was studied. The HPLC analysis was performed on a HIQ sil C18(4.6×250 mm) column with mobile phase of acetonitrile-water (3:7, V:V), flow rate 1 mL@(min-1 and UV detective wavelength 266 nm. Extracting 10-hydroxycamptothecin by ultrasonic method from fruits of C. acuminata to prepare samples for analysis was systematically discussed. The optimal extraction condition was carried out by 60% alcohol solution at 60℃ for 50 minutes.

  7. Fluorimetric assay for ornithine decarboxylase by high-performance liquid chromatography.

    Science.gov (United States)

    Haraguchi, K; Kai, M; Kohashi, K; Ohkura, Y

    1980-12-05

    A highly sensitive method for the assay of ornithine decarboxylase in sample solutions prepared from rat tissue homogenate is described which employs high-performance liquid chromatography with fluorescence detection. Putrescine formed from ornithine under the optimal conditions for the enzyme reaction is treated by Cellex P column chromatography for clean-up and converted into the fluorescamine derivative in the presence of cupric ion which inhibits the reaction of interfering amines with fluorescamine. The derivative is separated by reversed-phase chromatography on LiChrosorb RP-18 with linear gradient elution. The lower limit of detection for putrescine formed enzymatically is 5 pmol.

  8. Detection of cheese whey and caseinomacropeptide in fermented milk beverages using high performance liquid chromatography

    OpenAIRE

    E.H.P. Andrade; M.R. Souza; Fonseca,L.M.; C.F.A.M. Penna; M.M.O.P. Cerqueira; T. Roza; Seridan,B.; M.F.S. Resende; Pinto, F. A.; C.N.B.C. Villanoeva; Leite,M.O.

    2014-01-01

    Cheese whey level and caseinomacropeptide (CMP) index of fermented milk beverages added with four levels of cheese whey (0, 10, 20, and 40%) and stored at 8-10oC for 0, 7, 14 and 21 days were determined by high performance liquid chromatography-gel filtration (HPLC-GF). Additionally, the interference of the starter culture and the storage time on the detection of cheese whey and CMP were investigated. Refrigerated storage up to 21 days did not affect (P>0.05) cheese whey and CMP amounts in mi...

  9. Simultaneous determination of pseudoephedrine hydrochloride and cetrizine hydrochloride by reverse phase high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Nalini C

    2006-01-01

    Full Text Available A reversed phase high performance liquid chromatographic method has been developed using Shimadzu HPLC-VP series, LC-10 ATV pump, SPD10 AVP and C8 column, for simultaneous determination of pseudoephedrine hydrochloride and cetrizine hydrochloride in three marketed tablet formulations (extended release. The mobile phase consists of phosphate buffer of pH 7.0 and acetonitrile HPLC grade in the ratio of 1:1. The flow rate was maintained at 1 ml/min and the ultraviolet detection was done at 242 nm, which is the isosbestic point. Linearity coefficients, assay values, recovery studies and repeatability studies showed that the method is accurate and precise.

  10. Determination of nadolol in serum by high-performance liquid chromatography with fluorimetric detection.

    Science.gov (United States)

    Noguchi, H; Yoshida, K; Murano, M; Naruto, S

    1992-01-17

    A sensitive high-performance liquid chromatographic method for a routine assay of nadolol in serum is described. Serum samples spiked with atenolol (internal standard) were extracted with diethyl ether. After centrifugation, the organic layer was evaporated to dryness. The residue was redissolved in the mobile phase and injected onto an octadecyl silica column (150 mm x 4.6 mm I.D.). The mobile phase was 0.05 M ammonium acetate (pH 4.5)-acetonitrile (85:15, v/v). Fluorometric detection (excitation 230 nm, emission 300 nm) was used. The minimum detectable level of nadolol in serum was 1 ng/ml.

  11. A new method for high-performance liquid chromatographic determination of drotaverine in plasma.

    Science.gov (United States)

    Mezei, J; Küttel, S; Szentmiklósi, P; Marton, S; Rácz, I

    1984-10-01

    A sensitive, specific high-performance liquid chromatographic procedure was developed for the determination of plasma drotaverine levels. Basic plasma samples were adjusted to pH 1.5 and extracted with chloroform. HPLC [n-heptane-dichloromethane-diethylamine (50:25:2)] on a microporous silica column, with a variable-wavelength UV detector set at 302 nm allowed the measurement of drotaverine at the 50-ng/mL level. The utility of this method for determination of drotaverine in dog and rat plasma was demonstrated.

  12. Separation of polyamines, conjugated to DNA, by reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Mateos, J L; Reyes, A; Vicente, C; Legaz, M E

    2000-02-18

    Genomic DNA was isolated from the lichen Evernia prunastri in order to analyze by high-performance liquid chromatography the occurrence of polyamines conjugated to the macromolecule. The acid-insoluble (PH) fraction of this DNA contained mainly conjugated spermidine, although small amounts of free putrescine and spermidine were also present. The PH fraction of DNA also contained conjugated evernic acid, the main phenol produced by this lichen species. Conjugation of polyamines to calf thymus DNA was carried out under in vitro conditions. Conjugation was to spermidine and mainly to spermine and produced DNA compactation. Evernic acid enhanced the action of polyamines in order to produce DNA aggregation.

  13. Studies on the Fingerprint of Yubaizhi by High-Performance Liquid Chromato Graphy

    Institute of Scientific and Technical Information of China (English)

    YU Yu-hong; SUN Yan-ke; LI Xue-chun; DAI Rong-ji; MENG Wei-wei; DENG Yu-lin

    2008-01-01

    The investigation of fingerprint of Yubaizhi was performed by high-performance liquid chromatography (HPLC). Chromatographic conditions were: the mobile phase was the mixture of acetonitrile-water (43:57, v/v); the flow rate was 1mL/min; the column temperature was 40℃; the detection wavelength was 254nm. The stability, precision and reproducibility were performed according to "Specification of Fingerprint of Injection of Chinese Traditional Medicine (temporarily)" regulated by State Food and Drug Administration(SFDA). The HPLC fingerprints of Yubaizhi from various locations were well constant.

  14. Preparation and evaluation of surface-bonded tricationic ionic liquid silica as stationary phases for high-performance liquid chromatography.

    Science.gov (United States)

    Qiao, Lizhen; Shi, Xianzhe; Lu, Xin; Xu, Guowang

    2015-05-29

    Two tricationic ionic liquids were prepared and then bonded onto the surface of supporting silica materials through "thiol-ene" click chemistry as new stationary phases for high-performance liquid chromatography. The obtained columns of tricationic ionic liquids were evaluated respectively in the reversed-phase liquid chromatography (RPLC) mode and hydrophilic interaction liquid chromatography (HILIC) mode, and possess ideal column efficiency of 80,000 plates/m in the RPLC mode with naphthalene as the test solute. The tricationic ionic liquid stationary phases exhibit good hydrophobic and shape selectivity to hydrophobic compounds, and RPLC retention behavior with multiple interactions. In the HILIC mode, the retention and selectivity were evaluated through the efficient separation of nucleosides and bases as well as flavonoids, and the typical HILIC retention behavior was demonstrated by investigating retention changes of hydrophilic solutes with water volume fraction in mobile phase. The results show that the tricationic ionic liquid columns possess great prospect for applications in analysis of hydrophobic and hydrophilic samples.

  15. Gold nanoparticle decorated graphene oxide/silica composite stationary phase for high-performance liquid chromatography.

    Science.gov (United States)

    Liang, Xiaojing; Wang, Xusheng; Ren, Haixia; Jiang, Shengxiang; Wang, Licheng; Liu, Shujuan

    2014-06-01

    In the initial phase of this study, graphene oxide (GO)/silica was fabricated by assembling GO onto the silica particles, and then gold nanoparticles (GNPs) were used to modify the GO/silica to prepare a novel stationary phase for high-performance liquid chromatography. The new stationary phase could be used in both reversed-phase chromatography and hydrophilic interaction liquid chromatography modes. Good separations of alkylbenzenes, isomerides, amino acids, nucleosides, and nucleobases were achieved in both modes. Compared with the GO/silica phase and GNPs/silica phase, it is found that except for hydrophilicity, large π-electron systems, hydrophobicity, and coordination functions, this new stationary phase also exhibited special separation performance due to the combination of 2D GO with zero-dimensional GNPs.

  16. Fractionation of Gibberellins in plant extracts by reverse phase high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Jones, M.G.; Metzger, J.D.; Zeevaart, J.A.D.

    1980-02-01

    In studies on endogenous plant gibberellins (GAs), reverse phase (Bondapak C/sub 18/) high performance liquid chromatography (HPLC) has proved to be a useful method for the fractionation of plant extracts. The behavior of 18 authentic GAs in such a chromatographic system is described. The main factors determining chromatographic behavior are the degree and the position of hydroxylation of the GA. As an illustration of the use of reverse phase HPLC, the endogeneous GAs of immature seeds of Pharbitis nil L., strain Violet, were reinvestigated. The presence of gibberellins A/sub 3/, A/sub 5/, A/sub 17/, A/sub 20/, and A/sub 29/ was confirmed by gas-liquid chromatography-mass spectrometry. In addition, two other GAs, A/sub 19/ and A/sub 44/, were also identified in extracts of this material.

  17. High-performance liquid-catalyst fuel cell for direct biomass-into-electricity conversion.

    Science.gov (United States)

    Liu, Wei; Mu, Wei; Deng, Yulin

    2014-12-01

    Herein, we report high-performance fuel cells that are catalyzed solely by polyoxometalate (POM) solution without any solid metal or metal oxide. The novel design of the liquid-catalyst fuel cells (LCFC) changes the traditional gas-solid-surface heterogeneous reactions to liquid-catalysis reactions. With this design, raw biomasses, such as cellulose, starch, and even grass or wood powders can be directly converted into electricity. The power densities of the fuel cell with switchgrass (dry powder) and bush allamanda (freshly collected) are 44 mW cm(-2) and 51 mW cm(-2) respectively. For the cellulose-based biomass fuel cell, the power density is almost 3000 times higher than that of cellulose-based microbial fuel cells. Unlike noble-metal catalysts, POMs are tolerant to most organic and inorganic contaminants. Therefore, almost any raw biomass can be used directly to produce electricity without prior purification.

  18. An electrospray ionization-ion mobility spectrometer as detector for high- performance liquid chromatography.

    Science.gov (United States)

    Zühlke, Martin; Riebe, Daniel; Beitz, Toralf; Löhmannsröben, Hans-Gerd; Zenichowski, Karl; Diener, Marc; Linscheid, Michael W

    2015-01-01

    The application of electrospray ionization (ESI) ion mobility (IM) spectrometry on the detection end of a high-performance liquid chromatograph has been a subject of study for some time. So far, this method has been limited to low flow rates or has required splitting of the liquid flow. This work presents a novel concept of an ESI source facilitating the stable operation of the spectrometer at flow rates between 10 μL mn(-1) and 1500 μL min(-1) without flow splitting, advancing the T-cylinder design developed by Kurnin and co-workers. Flow rates eight times faster than previously reported were achieved because of a more efficient dispersion of the liquid at increased electrospray voltages combined with nebulization by a sheath gas. Imaging revealed the spray operation to be in a rotationally symmetric multijet mode. The novel ESI-IM spectrometer tolerates high water contents (≤90%) and electrolyte concentrations up to 10mM, meeting another condition required of high-performance liquid chromatography (HPLC) detectors. Limits of detection of 50 nM for promazine in the positive mode and 1 μM for 1,3-dinitrobenzene in the negative mode were established. Three mixtures of reduced complexity (five surfactants, four neuroleptics, and two isomers) were separated in the millisecond regime in stand-alone operation of the spectrometer. Separations of two more complex mixtures (five neuroleptics and 13 pesticides) demonstrate the application of the spectrometer as an HPLC detector. The examples illustrate the advantages of the spectrometer over the established diode array detector, in terms of additional IM separation of substances not fully separated in the retention time domain as well as identification of substances based on their characteristic Ims.

  19. Feeding of liquid silicon for high performance multicrystalline silicon with increased ingot height and homogenized resistivity

    Science.gov (United States)

    Krenckel, Patricia; Riepe, Stephan; Schindler, Florian; Strauch, Theresa

    2017-04-01

    Feeding of liquid silicon during the directional solidification process is a promising opportunity for cost reduction by increased throughput and improved material homogeneity due to constant resistivity over ingot height. In this work, a liquid feeding apparatus was developed for an industrial type directional solidification furnace. One n-type G2 sized High Performance multicrystalline ingot with liquid feeding of additional 14 kg of undoped silicon feedstock was crystallized. The resistivity was kept within a range of ±0.1 Ω cm of the target resistivity during the feeding sequence. A smaller mean grain area growth was observed during feeding, whereas the area fraction of recombination active dislocation structures was as low as in a reference ingot. Increased interstitial oxygen and substitutional carbon concentrations were measured for the ingot with liquid feeding. The measured mean bulk lifetime of 190 μs for passivated wafers in the feeding sequence can probably be increased by further pre-melting crucible improvements. For this laboratory experiment, energy reductions of 2% per wafer and time savings of 16% per wafer were realized.

  20. Unconventional High-Performance Laser Protection System Based on Dichroic Dye-Doped Cholesteric Liquid Crystals

    Science.gov (United States)

    Zhang, Wanshu; Zhang, Lanying; Liang, Xiao; Le Zhou; Xiao, Jiumei; Yu, Li; Li, Fasheng; Cao, Hui; Li, Kexuan; Yang, Zhou; Yang, Huai

    2017-01-01

    High-performance and cost-effective laser protection system is of crucial importance for the rapid advance of lasers in military and civilian fields leading to severe damages of human eyes and sensitive optical devices. However, it is crucially hindered by the angle-dependent protective effect and the complex preparation process. Here we demonstrate that angle-independence, good processibility, wavelength tunability, high optical density and good visibility can be effectuated simultaneously, by embedding dichroic anthraquinone dyes in a cholesteric liquid crystal matrix. More significantly, unconventional two-dimensional parabolic protection behavior is reported for the first time that in stark contrast to the existing protection systems, the overall parabolic protection behavior enables protective effect to increase with incident angles, hence providing omnibearing high-performance protection. The protective effect is controllable by dye concentration, LC cell thickness and CLC reflection efficiency, and the system can be made flexible enabling applications in flexible and even wearable protection devices. This research creates a promising avenue for the high-performance and cost-effective laser protection, and may foster the development of optical applications such as solar concentrators, car explosion-proof membrane, smart windows and polarizers. PMID:28230153

  1. Simultaneous determination of airborne carbamates in workplace by high performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Li, Hong-Ping; Li, Jen-Hou; Li, Gwo-Chen; Jen, Jen-Fon

    2004-06-17

    A high performance liquid chromatography with fluorescence (HPLC-F) detector was examined to simultaneous determination of airborne carbamates in the workplace of manufactory. The OVS-2 air sampling tube filled with glass fiber filter or quartz fiber and combined filter/XAD-2 were evaluated to collect nine commonly used carbamates (Carbofuran, Isoprocarb, Methomyl, Metolcarb, Thiodicarb, Carbaryl, Oxamyl, Methiocarb, and Prpoxur) from the air of manufactory in high humidity country. After being extracted with acetonitrile from sampling tubes, the carbamates were determined by high performance liquid chromatography with fluorescence detection posterior to on-line derivatization. The collection of carbamates and the recovery of extraction from glass wool fiber in several concentration levels, and from quartz filter were evaluated. The storage stability of carbamates was also tested. Results indicated that the HPLC-fluorescence method offers satisfactory resolution and sensitivity in carbamate analysis. With the glass fiber filter and combined filter/XAD-2, the Carbofuran, Isoprocarb, Methomyl, Metolcarb, and Thiodicarb were stable for a 28-day storage test, Carbaryl and Oxamyl for 14 days, and Methiocarb and Prpoxur for 7 days. All of these pesticides were with detection limit of 3mugm(-3). It is suited for environmental monitoring. The airborne carbamates in different areas of the manufactory were measured.

  2. Hb A1c Separation by High Performance Liquid Chromatography in Hemoglobinopathies

    Science.gov (United States)

    Chandrashekar, Vani

    2016-01-01

    Hb A1c measurement is subject to interference by hemoglobin traits and this is dependent on the method used for determination. In this paper we studied the difference between Hb A1c measured by HPLC in hemoglobin traits and normal chromatograms. We also studied the correlation of Hb A1c with age. Hemoglobin analysis was carried out by high performance liquid chromatography. Spearman's rank correlation was used to study correlation between A1c levels and age. Mann-Whitney U test was used to study the difference in Hb A1c between patients with normal hemoglobin and hemoglobin traits. A total of 431 patients were studied. There was positive correlation with age in patients with normal chromatograms only. No correlation was seen in Hb E trait or beta thalassemia trait. No significant difference in Hb A1c of patients with normal chromatograms and patients with hemoglobin traits was seen. There is no interference by abnormal hemoglobin in the detection of A1c by high performance liquid chromatography. This method cannot be used for detection of A1c in compound heterozygous and homozygous disorders. PMID:26989559

  3. Hb A1c Separation by High Performance Liquid Chromatography in Hemoglobinopathies

    Directory of Open Access Journals (Sweden)

    Vani Chandrashekar

    2016-01-01

    Full Text Available Hb A1c measurement is subject to interference by hemoglobin traits and this is dependent on the method used for determination. In this paper we studied the difference between Hb A1c measured by HPLC in hemoglobin traits and normal chromatograms. We also studied the correlation of Hb A1c with age. Hemoglobin analysis was carried out by high performance liquid chromatography. Spearman’s rank correlation was used to study correlation between A1c levels and age. Mann-Whitney U test was used to study the difference in Hb A1c between patients with normal hemoglobin and hemoglobin traits. A total of 431 patients were studied. There was positive correlation with age in patients with normal chromatograms only. No correlation was seen in Hb E trait or beta thalassemia trait. No significant difference in Hb A1c of patients with normal chromatograms and patients with hemoglobin traits was seen. There is no interference by abnormal hemoglobin in the detection of A1c by high performance liquid chromatography. This method cannot be used for detection of A1c in compound heterozygous and homozygous disorders.

  4. Determination of Niacinamide in Lotions and Creams Using Liquid-Liquid Extraction and High-Performance Liquid Chromatography

    Science.gov (United States)

    Usher, Karyn M.; Simmons, Carolyn R.; Keating, Daniel W.; Rossi, Henry F., III

    2015-01-01

    Chemical separations are an important part of an undergraduate chemistry curriculum. Sophomore students often get experience with liquid-liquid extraction in organic chemistry classes, but liquid-liquid extraction is not as often introduced as a quantitative sample preparation method in honors general chemistry or quantitative analysis classes.…

  5. Determination of Niacinamide in Lotions and Creams Using Liquid-Liquid Extraction and High-Performance Liquid Chromatography

    Science.gov (United States)

    Usher, Karyn M.; Simmons, Carolyn R.; Keating, Daniel W.; Rossi, Henry F., III

    2015-01-01

    Chemical separations are an important part of an undergraduate chemistry curriculum. Sophomore students often get experience with liquid-liquid extraction in organic chemistry classes, but liquid-liquid extraction is not as often introduced as a quantitative sample preparation method in honors general chemistry or quantitative analysis classes.…

  6. Ultrasound-assisted ionic liquid-based homogeneous liquid-liquid microextraction high-performance liquid chromatography for determination of tanshinones in Salvia miltiorrhiza Bge. root.

    Science.gov (United States)

    Wang, Zhibing; Cao, Bocheng; Yu, Aimin; Zhang, Hanqi; Qiu, Fangping

    2015-02-01

    The ultrasound-assisted ionic liquid-based homogeneous liquid-liquid microextraction has been developed and applied to the extraction of four tanshinones, including dihydrotanshinone, tanshinone I, cryptotanshinone and tanshinone IIA in Salvia miltiorrhiza Bge. root. High performance liquid chromatography was applied to the separation and determination of the analytes. The ionic liquid was used as extraction solvent and target analytes were extracted with help of ultrasound. Then, ion-pairing agent was added into the sample solution, which resulted in the formation of water-insoluble ionic liquid in the solution. The phase separation was performed by centrifugation. The extraction, concentration and purification of target analytes were performed simultaneously. The experimental parameters, including type and volume of ionic liquid, sample amount, the size of sample particle, pH value of extraction medium, extraction temperature, extraction time, amount of ion-pairing agent and centrifuging time, were investigated and optimized. The calibration curves showed good linear relationship (r>0.9997). The limits of detection and quantification were in the range of 0.052-0.093 and 0.17-0.31 μg mL(-1), respectively. The recoveries were between 70.45% and 94.23% with relative standard deviations lower than 5.31%. The present method is free of volatile organic solvents, and represents lower expenditures of sample, extraction time and solvent, compared with UAE and HRE. There was no obvious difference in the extraction yields of active constitutions obtained by the three extraction methods.

  7. Development and validation of high performance liquid chromatographic method for analysis of clozapine.

    Science.gov (United States)

    Kaur, Harpreet; Bassi, Pallavi; Monif, Tausif; Khuroo, Arshad; Kaur, Gurpreet

    2013-05-01

    In this study a rapid, simple and sensitive assay to quantify clozapine in human plasma by using reverse phase high performance liquid chromatographic method has been developed. Clozapine was extracted from human plasma using a mixture of chloroform: n-hexane 50:50 employing liquid-liquid extraction method. The calibration curve was found to be linear in the concentration range of 25-800 ng/ml. The inter day and intra day assay accuracy and precision fulfilled the criteria specified by USFDA, Guidance for industry: bioanalytical method validation. Clozapine was found to be stable in human plasma after 6 h incubation at room temperature, 50 days storage at -27°C and freeze thaw cycles, as well as after reconstitution with mobile phase after 24 h of storage in refrigerator. The validated method offers the advantage of using minimum injection volume (25μl) and plasma sample volume (300μl). The extraction method is simple and single step with no back extraction step, thus, making this method applicable to determination of pharmacokinetic profiles and parameters.

  8. High performance liquid chromatographic method fo pyrantel tartrate in swine feeds and supplements.

    Science.gov (United States)

    Goras, J T

    1981-11-01

    A new method for the determination of pyrantel tartrate in swine feed an supplements has been developed because the current official AOAC method is not applicable to feeds co-medicated with tylosin. The new method involves: (a) leaching of drug from feed with methanolic NaCl solution, (b) removal of interfering substances by ion pair liquid-liquid extraction and high performance liquid chromatography, and (c) quantitation of pyrantel tartrate by monitoring the ultraviolet absorption of the effluent stream at 313nm. The method of standard addition is used to compensate for the effect of the feed matrix on drug recovery. No interference is encountered from tylosin, carbadox, lincomycin, non-drug components of feeds and supplements, or potential degradation products of pyrantel tartrate, i.e., cis isomer of pyrantel tartrate and (E)-N-(3-methylaminopropyl)-2-thiopheneacrylamide. Results for the assay of 3 lots each of feeds and supplements containing 0.0106 and 0.106% pyrantel tartrate, respectively, were within +/-4% of label claim. Coefficients of variation ranged from 1.6 to 1.8% for feeds and from 1.9 to 3.9% for supplements.

  9. Determination of Harmine and Harmaline in Peganum harmala Seeds by High-Performance Liquid Chromatography

    Science.gov (United States)

    Monsef-Esfahani, Hamid Reza; Faramarzi, Mohammad Ali; Mortezaee, Venus; Amini, Mohsen; Rouini, Mohammad Reza

    A High-Performance Liquid Chromatography (HPLC) method was developed for determination of harmine, harmaline, harmol and harmalol in the extract of Peganum harmala seeds. The sample preparation was performed using liquid-liquid extraction. Chromatographic separation was achieved with a Tracer Excel 120 ODSA (150x4.6 mm) column, using a mixture of potassium phosphate buffer (10 mM, pH 7.0): acetonitrile (100:30; v/v) as mobile phase, in an isocratic mode at 1.5 mL min-1. UV detection (λ = 330 nm) was used. The calibration curves were linear (r2>0.998) in the concentration range of 0.5-20 μg mL-1 for all analytes. The lower limit of quantification for all analytes was 0.5 μg mL-1. The within and between day precisions in the measurement of QC samples at three tested concentrations were in the range of 0.6-10.2% for all analytes. The HPLC method is able to measure the harmala alkaloids in the plant extract. The method has suitable reproducibility, sensitivity and resolution for routine and accurate use with UV detection.

  10. Surveillance of the Army’s Propellant Stockpile: Analysis of Stabilizer Content by High Performance Liquid Chromatography

    Science.gov (United States)

    1990-10-01

    high performance liquid chromatography to monitor the level of stabilizer and its daughter products in propellant. Three of those methods are presented along with statistics and some comments about their

  11. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY OF COBALT(III) MIXED LIGAND COMPLEXES WITH ACETYLACETONATE AND OXINATE AND MONOMETHYLOXINATE IONS

    National Research Council Canada - National Science Library

    Kidani, Yoshinori; Naga, Shinobu; Koike, Hisashi

    1976-01-01

    In the presence of Co(III) mixed ligand complexes with acetylacetonate, and oxinate and monomethyloxinate ions, the authors attempted to employ high performance liquid chromatography, HPLC, for the separation and purification...

  12. Sensitive determination of 4-O-methylhonokiol in rabbit plasma by high performance liquid chromatography and application

    Institute of Scientific and Technical Information of China (English)

    Ming-Yue Li; Yu-Hai Tang; Xia Liu; Hai-Yan Lu; Xi-Yan Shi

    2011-01-01

    A novel high performance liquid chromatographic method was developed for the determination of 4-O- methylhonokiol in rabbit plasma and was applied to its pharmacokinetic investigation. Plasma samples were treated by one-fold volume of methanol and acetoni

  13. Extraction and determination of hormones in cosmetics by homogeneous ionic liquid microextraction high-performance liquid chromatography.

    Science.gov (United States)

    Kang, Mingqin; Sun, Shuo; Li, Na; Zhang, Daihui; Chen, Mingyan; Zhang, Hanqi

    2012-08-01

    The homogeneous ionic liquid microextraction was applied to the extraction of hormones from cosmetics and the hormones were determined by high-performance liquid chromatography. 1-Hexyl-3-methylimidazolium tetrafluoroborate was used as extraction solvent. Ammonium hexafluorophosphate as used as ion-pairing agent. Several experimental parameters, including the volume of 1-hexyl-3-methylimidazolium tetrafluoroborate, amount of ammonium hexafluorophosphate and sodium chloride, extraction and centrifuge time, and the pH value, were optimized. The limits of detection and quantification for the analytes ranged from 0.03 to 0.24 ng/mL and from 0.10 to 0.79 ng/mL, respectively. The precision for determining the hormones was lower than 5.2%. The proposed method was successfully developed for the determination of hormones in real cosmetic samples.

  14. Determination of Four Pesticides in Soil by Homogeneous Ionic Liquid-based Microextraction Coupled with High-performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    YAN Rui; SHAO Ming-yuan; LIANG Zhen-fen; ZHANG Han-qi; YU Ai-min

    2013-01-01

    Homogeneous ionic liquid microextraction was developed for the simultaneceus extraction of dimethomorph,mefenacet,isoprothiolane and oxadiazon from soil.1-Butyl-3-methylimidazolium tetrafluoroborate was used as extraction solvent,and ammonium hexafluorophosphate was used as ion-pairing agent.High-performance liquid chromatography(HPLC) was employed for separation and determination of the analytes.The calibration curves show good linear relationship(r>0.9988).The recoveries are between 74.2% and 97.9% with relative standard deviations(RSDs) lower than 5.97%.The present method is free of volatile organic solvents,and expenditures of sample,extraction time and solvent are lower,compared with ultrasonic and Soxhlet extraction.There was no obvious difference in the extraction recoveries of pesticides obtained by the three extraction methods.

  15. Determination of captopril by high-performance liquid chromatography with direct electrogenerated chemiluminescence

    Science.gov (United States)

    Sun, Yonghua; Zhang, Zhujun; Zhang, Xinfeng

    2013-03-01

    Captopril exhibit electrogenerated chemiluminescence (ECL) in NaNO3 solution when constant current is exerted. Based on this observation, a direct ECL method coupled with high-performance liquid chromatography (HPLC) separation is developed for determination of captopril in human serum. Factors affected the ECL emission are investigated. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of captopril in the range of 4.0 × 10-6-2.0 × 10-3 g mL-1 and the detection limit is 2 × 10-6 g mL-1 (S/N = 3). Compared with the common electrogenerated chemiluminescence experiments, the developed method need no any other fluorescence additives.

  16. Hydrocarbon group type determination in jet fuels by high performance liquid chromatography

    Science.gov (United States)

    Antoine, A. C.

    1977-01-01

    Results are given for the analysis of some jet and diesel fuel samples which were prepared from oil shale and coal syncrudes. Thirty-two samples of varying chemical composition and physical properties were obtained. Hydrocarbon types in these samples were determined by fluorescent indicator adsorption (FIA) analysis, and the results from three laboratories are presented and compared. Recently, rapid high performance liquid chromatography (HPLC) methods have been proposed for hydrocarbon group type analysis, with some suggestion for their use as a replacement of the FIA technique. Two of these methods were used to analyze some of the samples, and these results are also presented and compared. Two samples of petroleum-based Jet A fuel are similarly analyzed.

  17. Analysis of lipophilic pigments from a phototrophic microbial mat community by high performance liquid chromatography

    Science.gov (United States)

    Palmisano, A. C.; Cronin, S. E.; Des Marais, D. J.

    1988-01-01

    As assay for lipophilic pigments in phototrophic microbial mat communities using reverse phase-high performance liquid chromatography was developed which allows the separation of 15 carotenoids and chloropigments in a single 30 min program. Lipophilic pigments in a laminated mat from a commercial salina near Laguna Guerrero Negro, Baja California Sur, Mexico reflected their source organisms. Myxoxanthophyll, echinenone, canthaxanthin, and zeaxanthin were derived from cyanobacteria; chlorophyll c, and fucoxanthin from diatoms; chlorophyll a from cyanobacteria and diatoms; bacteriochlorophylls a and c, bacteriophaeophytin a, and gamma-carotene from Chloroflexus spp.; and beta-carotene from a variety of phototrophs. Sensitivity of detection was 0.6-6.1 ng for carotenoids and 1.7-12 ng for most chloropigments. This assay represents a significant improvement over previous analyses of lipophilic pigments in microbial mats and promises to have a wider application to other types of phototrophic communities.

  18. Simultaneous Determination of Five Components Including Acetaminophen by Reversed-phase High Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    ZHANG Li-qing; WU Xiao-hua; LU Ying; WANG Xia

    2004-01-01

    High performance liquid chromatography with a C18 reverse-phase column was used to separatethe five components in cough syrup, including acetaminophen, p-aminophenol, caffeine, chlorphenamine maleateand guaifenesin. The mobile phase consists of 15wi% acetonitrile, 0.004mol/L sodium heptyl sulfonate,0.03 mole/L potassium di- hydrogen phosphate and triethylamine ( volume ratio 13: 40: 44: 3), the pH of which isadjusted to 3.0 by phosphoric acid. The contents of the five components are analyzed on an ultraviolet spectropho-tometer at 254nm, with a flow rate of 0.4mL/min. The results show that the calibration curves are linear in acertain range. The average recovery of five components is between 96.31% and 102.3% .

  19. Determination of free urinary cortisol in cushing's syndrome using reversed-phase high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Eduardo Kinio Sugawara

    2010-01-01

    Full Text Available Determination of free urinary cortisol is a test of choice in the diagnosis of Cushing's syndrome. In this study, cortisol was quantified using reversed-phase high-performance liquid chromatography (RP-HPLC in urine samples previously extracted with ether and using triamcinolone acetonide as internal standard (IS. A BDS-Hypersil-C18® column, water-acetonitrile (72:28; v/v, with a flow rate of 1.0 mL/min and detection at 243 nm were used. This method showed to be both effective and efficient, with sensitivity and linearity ranging from 2.50 to 150 μg/L, and can be used in substitution to the radioimmunoassay technique within this concentration range.

  20. High performance liquid chromatography study of complex oxygenated alkane mixtures from organic aerosols

    Science.gov (United States)

    Kalafut-Pettibone, Alicia J.; Klems, Joseph P.; McGivern, W. Sean

    2013-05-01

    The composition of secondary organic aerosol particles is of primary importance both in identifying particle sources and in determining physical parameters, such as cloud condensation nucleus propensity. Further, measurements of composition are valuable in determining the chemistry of formation and aging. In this work, we describe the application of a recently-developed derivatization technique to a complex synthetic organic aerosol derived from the photolysis of 1-iodooctane. The technique utilizes high-performance liquid chromatography (HPLC) coupled to both ultravioletvisible (UV/VIS) spectroscopy and tandem mass spectrometry (MS-MS) to determine the overall distribution of hydroxyl (OH), non-acid carbonyl (C=O), and carboxylic acid (COOH) moieties as well as the specific identities of chromatographically separated products. This composition data will then be used to constrain models of the particle formation mechanisms.

  1. The search for more pH stable stationary phases for high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Collins, Carol H.; Silva, Cesar R.; Faria, Anizio M.; Collins, Kenneth E.; Jardim, Isabel Cristina S.F. [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Inst. de Quimica

    2009-07-01

    High performance liquid chromatographic (HPLC) separations are largely carried out using reversed phase conditions with stationary phases based on silica. A serious problem with these stationary phases is the tendency of silica to dissolve in high pH solutions often needed to separate basic compounds. The literature reports many different ways that have been tried to resolve this problem. This paper reports the results obtained in our laboratory with stationary phases prepared using silica supports having a layer of a metal oxide (zirconia or titania) attached on their surfaces, followed by immobilization of a polysiloxane or by organofunctionalization with a trimethoxyalkylsilane. Stability tests, also developed in our laboratory, indicate that the metal oxide layer increases the HPLC column lifetimes by making the stationary phase less susceptible to dissolution. (author)

  2. Analysis of carotenoid and porphyrin pigments of geochemical interest by high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Hajibrahim, S.K. (Univ. of Bristol, Eng.); Tibbetts, P.J.C.; Watts, C.D.; Maxwell, J.R.; Eglinton, G.; Colin, H.; Guiochon, G.

    1978-04-01

    High-performance liquid chromatography (HPLC) is shown to be a powerful tool in the analysis of carotenoid and porphyrin pigments. Columns packed with 5-..mu..m irregular silica gel particles by a high density and high constant pressure method allow efficient separation of mixtures of total nonsaponifiable carotenoids from recent sedimentary situations. Good reproducibility of retention times (within 2%) is achieved in the gradient elution mode. However, attention must be paid to reequilibration of the column after each injection by washing with the less polar solvent for a minimum of 15 min (for carotenoids) or of 30 min (for porphyrins). HPLC appears to be useful in ''fingerprinting'' petroporphyrin distributions in crude oil.

  3. Simultaneous determination of tricarboxylic acid cycle metabolites by high-performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Shurubor, Yevgeniya I; Cooper, Arthur J L; Isakova, Elena P; Deryabina, Yulia I; Beal, M Flint; Krasnikov, Boris F

    2016-06-15

    Here we describe a simple high-performance liquid chromatography (HPLC) procedure for the simultaneous detection and quantitation in standard solutions of 13 important metabolites of cellular energy metabolism, including 9 tricarboxylic acid (TCA) cycle components and 4 additional metabolites. The metabolites are detected by their absorbance at 210 nm. The procedure does not require prior derivatization, and an analysis can be carried out at ambient temperature within 15 min. The significance of the current work is that the current HPLC procedure should motivate the development of simplified TCA cycle enzyme assays, isotopomer analysis, and determination of selected TCA metabolite levels in plasma/tissues. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Development of N-ferrocenyl(benzoyl)amino-acid esters stationary phase for high performance liquid chromatography.

    Science.gov (United States)

    Zhou, Xiaohua; Li, Xiaole; Cao, Aijuan; Lijun, Qiao; Yu, Ajuan; Zhang, Shusheng; Wu, Yangjie

    2015-11-01

    A new stationary phase for high-performance liquid chromatography was prepared by covalently bonding N-ferrocenyl(benzoyl)amino-acid esters (L(1)) onto silica gel using 3-aminopropyltriethoxysilane as coupling reagent. The structure of new material was characterized by infrared spectroscopy, elemental analysis and thermogravimetric analysis. The chromatographic behavior of the phase was illustrated in reversed-phase (RP) and normal-phase (NP) modes using polycyclic aromatic hydrocarbons (PAHs), aromatics positional isomers, amines, 5-nitroimidazoles, organophosphorus pesticides and phenols as probes. Multiple mechanisms including hydrophobic, hydrogen bonding, π-π, dipole-dipole, charge-transfer and acid-base equilibrium interactions are involved. Thus, multi-interaction mechanisms and mixed-mode separation of the new phase can very likely guarantee its excellent chromatographic performance for the analysis of complex samples. The L(1) AminoSil column was successfully employed for the analysis of organophosphorus pesticides in vegetable.

  5. Quantitative determination of gibberellins by high performance liquid chromatography from various gibberellins producing Fusarium strains.

    Science.gov (United States)

    Bhalla, Kirti; Singh, Shashi Bala; Agarwal, Rashmi

    2010-08-01

    High performance liquid chromatographic (HPLC) method was developed for analysis of seven gibberellins, i.e., GA3, GA4, GA7, GA3 methyl ester, GA7 methyl ester 3,13 diacetate, GA7 methyl ester, and fusaric acid, using an isocratic system. Method was used for estimation of gibberellins from different Fusarium strains. Gibberellins were extracted from 28 strains of Fusarium, out of which six strains of Fusarium were isolated from soil of different parts of India and 22 strains were procured from the Indian Type Culture Collection, Indian Agricultural Research Institute, New Delhi. Extracts were analyzed for qualitative and quantitative estimation of gibberellins by thin layer chromatography and HPLC, respectively. On the basis of quantitative analysis of produced gibberellins by HPLC, they were categorized as low, moderate, and high gibberellin producing strain. For the first time, Fusarium solani was also reported as high GA3 producing strain.

  6. DETERMINATION OF PROTEINS FROM BUFFALO MILK USING HIGH PERFORMANCE LIQUID CROMATOGRAPHY RP-HPLC

    Directory of Open Access Journals (Sweden)

    AURELIA PECE

    2013-12-01

    Full Text Available In the hereby paper, we have undertaken a study on buffalo milk proteins, employing high performance liquid chromatography (HPLC. This RP-HPLC technique is commonly employed in the separation and assessment of caseins K, and in the fresh, as well as processed milk. These methods are also successfully applied in the authenticity and origin assessment of certain cheese products and the qualitative analysis of milk in bubalines, ovines, caprines and bovines (Ferreira si Cacote, 2003; Veloso si colab., 2002. In order to identify the main protein types, we found support in literature data (Miranda si colab., 2004, and thus achieved the chromatographic separation on whole milk, lactoserum and casein samples.

  7. Creation of reversed phase high-performance liquid chromatographic technique to assay platelet-activating factor

    Institute of Scientific and Technical Information of China (English)

    杨云梅; 曹红翠; 徐哲荣; 陈晓明

    2004-01-01

    Objective: To establish a new assay for platelet-activating factor (PAF), to compare it with bio-assay; and to discuss its significance in some elderly people diseases such as cerebral infarction and coronary heart disease. Methods: To measure PAF levels in 100 controls, 23 elderly patients with cerebral infarction and 65 cases with coronary heart disease by reversed phase high-performance liquid chromatographic technique (rHPLC). Results: rHPLC is more convenient, sensitive, specific, and less confusing, compared with bio-assay. The level of plasma PAF in patients with cerebral infarction was higher than that in the controls (P<0.01), and in patients with coronary heart disease. Conclusion: Detection of PAF with rHPLC is more reliable and more accurate. The new assay has important significance in PAF research.

  8. Creation of reversed phase high-performance liquid chromatographic technique to assay platelet-activating factor

    Institute of Scientific and Technical Information of China (English)

    杨云梅; 曹红翠; 徐哲荣; 陈晓明

    2004-01-01

    Objective: To establish a new assay for platelet-activating factor (PAF), to compare it with bio-assay; and to discuss its significance in some elderly people diseases such as cerebral infarction and coronary heart disease. Methods: To measure PAF levels in 100 controls, 23 elderly patients with cerebral infarction and 65 cases with coronary heart disease by reversed phase high-performance liquid chromatographic technique (rHPLC). Results:rHPLC is more convenient, sensitive,specific, and less confusing, compared with bio-assay. The level of plasma PAF in patients with cerebral infarction was higher than that in the controls (P<0.01), and in patients with coronary heart disease. Conclusion: Detection of PAF with rHPLC is more reliable and more accurate. The new assay has important significance in PAF research.

  9. [Detection of the preservative chlorphenesin in cosmetics by high-performance liquid chromatography].

    Science.gov (United States)

    Ikarashi, Yoshiaki; Miyazawa, Norimasa; Shimamura, Kimio; Sato, Nobuo; Yoshizawa, Ken-ichi; Hayashi, Masahito; Takano, Katsuhiro; Miyamoto, Michiko; Kojima, Takashi; Sakaguchi, Hiroshi; Fujiio, Makiko

    2009-01-01

    A simple determination method for preservative chlorphenesin in cosmetics was developed. Cosmetic samples were dissolved in methanol. The sample solution was analyzed by high-performance liquid chromatography (HPLC) with ODS column, using water-methanol (55:45) or water-acetonitrile (3:1) adjusted to pH 2.5 with phosphoric acid as the mobile phase. Chlorphenesin was detected with ultraviolet light detection at 280 nm. A linear relation was obtained between the peak areas and the concentrations of chlorphenesin in the range of 1-500 microg/ml. The determination limit of chlorphenesin was 1-2 microg/ml. Recoveries of chlorphenesin spiked in lotion and milky lotion at the levels of 0.03% and 0.3% were 98.8-100.0%. This method was applied for cosmetics including 0.03% and 0.3% of chlorphenesin and their content corresponded with the determined values.

  10. High-performance liquid chromatographic analysis of anthraquinone compounds in the Laurera benguelensis

    Science.gov (United States)

    Manojlović, N.; Marković, Z.; Gritsanapan, W.; Boonpragob, K.

    2009-09-01

    A high-performance liquid chromatographic (HPLC) method has been developed for the characterization of anthraquinone metabolites in extracts of the lichen Laurera benguelensis. With this method four anthraquinone derivatives 1,8-dihydroxy-3-methoxy-6-methylanthraquinone, 1,8-dihydroxy-3-formyl-6-methoxyanthraquinone, 1,8-dihydroxy-3-hydroxymethyl-6-methoxy-anthraquinone and 1,3,8-trihyroxy-6-methylanthraquinone can be analyzed. Components of lichen were detected by characteristic ultraviolet spectra and relative retention times. This is first report of phytochemical analysis of L. benguelensis. Importance of this research is in recognizing some new source (lichen and its extracts) as a natural emplacement of antioxidants because oxidation with free radicals or autooxidation is big problem for preservation of food products.

  11. Postcolumn photolysis of pesticides for fluorometric determination by high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Miles, C.J.; Moye, H.A.

    1988-02-01

    A high-performance liquid chromatography postcolumn reaction detector that employs UV photolysis with an optional reaction by using o-phthalaldehyde-2-mercaptoethanol (OPA-MERC) followed by fluorescence detection was found to be useful for several classes of pesticides. In the presence of the OPA-MERC reagent, most carbamates, carbamoyl oximes, carbamothioic acids, and substituted ureas gave a sensitive response while the response of dithiocarbamates, phenylamides, and phenylcarbamates varied. The response of most of the pesticides tested was significantly affected by the solvent used. Method detection limits for aldicarb sulfoxide, aldicarb, propoxur, thiram, and neburon in ground water were 2.5, 2.3, 3.3, 3.8, and 2.0 ..mu..g/L, respectively. In the absence of OPA-MERC reagent, several of the substituted aromatic compounds also gave strong fluorescence after photolysis. This detector is applicable to a broad range of nitrogenous pesticides.

  12. A high performance liquid chromatography method for determination of furfural in crude palm oil.

    Science.gov (United States)

    Loi, Chia Chun; Boo, Huey Chern; Mohammed, Abdulkarim Sabo; Ariffin, Abdul Azis

    2011-09-01

    A modified steam distillation method was developed to extract furfural from crude palm oil (CPO). The collected distillates were analysed using high performance liquid chromatography (HPLC) coupled with an ultraviolet diode detector at 284nm. The HPLC method allowed identification and quantification of furfural in CPO. The unique thermal extraction of CPO whereby the fresh fruit bunches (FFB) are first subjected to steam treatment, distinguishes itself from other solvent-extracted or cold-pressed vegetable oils. The presence of furfural was also determined in the fresh palm oil from FFB (without undergoing the normal extraction process), palm olein, palm stearin, olive oil, coconut oil, sunflower oil, soya oil and corn oil. The chromatograms of the extracts were compared to that of standard furfural. Furfural was only detected in CPO. The CPO consignments obtained from four mills were shown to contain 7.54 to 20.60mg/kg furfural.

  13. Determination of 15 isoflavone isomers in soy foods and supplements by high-performance liquid chromatography.

    Science.gov (United States)

    Yanaka, Kaoru; Takebayashi, Jun; Matsumoto, Teruki; Ishimi, Yoshiko

    2012-04-25

    Soy isoflavone is the generic name for the isoflavones found in soy. We determined the concentrations of 15 soy isoflavone species, including 3 succinyl glucosides, in 22 soy foods and isoflavone supplements by high-performance liquid chromatography (HPLC). The total isoflavone contents in 14 soy foods and 8 supplements ranged from 45 to 735 μg/g and from 1,304 to 90,224 μg/g, respectively. Higher amounts of succinyl glucosides were detected in natto, a typical fermented soy product in Japan; these ranged from 30 to 80 μg/g and comprised 4.1-10.9% of the total isoflavone content. In soy powder, 59 μg/g of succinyl glucosides were detected, equivalent to 4.6% of the total isoflavone content. These data suggest that the total isoflavone contents may be underestimated in the previous studies that have not included succinyl glucosides, especially for Bacillus subtilis -fermented soy food products.

  14. A simple high performance liquid chromatography method for determination of rebamipide in rat urine.

    Science.gov (United States)

    Cooper, Dustin L; Harirforoosh, Sam

    2014-01-01

    Rebamipide is a mucoprotective agent commonly used to prevent nonsteriodal anti-inflammatory drug-induced gastrointenstinal side effects [1]. Human plasma and urine analysis of rebamipide utilizing high performance liquid chromatography (HPLC) have been reported [2]. Recently, we reported on the plasma levels of rebamipide in presense or absence of celecoxib or diclofenac in rats [3] using a modified HPLC method of detection developed by Jeoung et al. [4]. To tailor the method towards use in urinary rebamipide extraction and analysis, the following modifications were made:•To compensate for high concentrations of rebamipide found in urine, a new rebamipide stock solution was prepared with a final concentration of 50,000 ng/mL.•Rat urine calibration standards were obtained within the range of 50-1000 ng/mL and 1000-50,000 ng/mL.•Plasma samples were replaced with urine samples.

  15. A validated new method for nevirapine quantitation in human plasma via high-performance liquid chromatography.

    Science.gov (United States)

    Silverthorn, Courtney F; Parsons, Teresa L

    2006-01-01

    A fully validated and clinically relevant assay was developed for the assessment of nevirapine concentrations in neonate blood plasma samples. Solid-phase extraction with an acid-base wash series was used to prepare subject samples for analysis. Samples were separated by high performance liquid chromatography and detected at 280 nm on a C8 reverse-phase column in an isocratic mobile phase. The retention times of nevirapine and its internal standard were 5.0 and 6.9 min, respectively. The method was validated by assessment of accuracy and precision (statistical values 0.996) and the average recovery was 93% (n = 18). The lower limit of quantification (relative standard deviation <20%) was determined to be 25 ng/mL for 50 microL of plasma, allowing detection of as little as 1.25 ng of nevirapine in a sample. This value represents an increase in sensitivity of up to 30-fold over previously published methods.

  16. Determination of Sex Hormones in Antler Velvet by High Performance Liquid Chromatography Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    LU Chun-mei; WANG Ming-tai; MU Jun; BAI Yu-ping; DU Jian-shi; ZHANG Han-qi; WANG Jian-wei

    2012-01-01

    Eighteen sex hormones in antler velvet were determined by high performance liquid chromatography tandem mass spectrometry.The solid phase extraction was applied to eliminating the matrix effect.The experimental conditions were examined and optimized.Under the optimal conditions,the proposed method provides the good linearities and determination limits(0.2-1.0 μg/kg)of the analytes investigated.The recoveries ranging from 72.3% to 149.5% were obtained for the target analytes at two concentration levels.This method was applied to the determination of eighteen sex hormones in different kinds of antler velvet samples and the obtained results are satisfactory.The results indicate that the proposed method is suitable for the determination of sex hormones in antler velvet samples.

  17. Improved high-performance liquid chromatographic analysis of terazosin in human plasma.

    Science.gov (United States)

    Cheah, P Y; Yuen, K H; Liong, M L

    2000-08-18

    A simple, sensitive and reproducible high-performance liquid chromatography (HPLC) method was developed for the determination of terazosin in human plasma. The method involves a one-step single solvent extraction procedure using dichloromethane with a 0.25 ml plasma sample. Recovery values were all greater than 90% over the concentration range 0.25-100 ng/ml. Terazosin was found to adsorb to glass or plastic tubes, but this could be circumvented by using disposable plastic tubes. Also, rinsing the injector port with methanol after each injection helped to prevent any carry-over effect. The internal standard, prazosin, did not exhibit this problem. The method has a quantification limit of 0.25 ng/ml. The within- and between-day coefficient of variation and accuracy values were all less than 7% over the concentration range 0.25-100 ng/ml and hence the method is suitable for use in pharmacokinetic studies of terazosin.

  18. Measurement of serum pralidoxime methylsulfate (Contrathion) by high-performance liquid chromatography with electrochemical detection.

    Science.gov (United States)

    Houzé, Pascal; Borron, Stephen W; Scherninski, François; Bousquet, Bernard; Gourmel, Bernard; Baud, Frédéric

    2005-01-05

    Pralidoxime methylsulfate (Contrathion) is widely used to treat organophosphate poisoning. Despite animal and human studies, the usefulness of Contrathion therapy remains a matter of debate. Therapeutic dosage regimens need to be clarified and availability of a reliable method for plasma pralidoxime quantification would be helpful in this process. We here describe a high-performance liquid chromatography technique with electrochemical detection to measure pralidoxime concentrations in human serum using guanosine as an internal standard. The assay was linear between 0.25 and 50 microg mL(-1) with a quantification limit of 0.2 microg mL(-1). The analytical precision was satisfactory, with variation coefficients lower 10%. This assay was applied to the analysis of a serum from an organophosphorate poisoned patient and treated by Contrathion infusions (100 and 200 mg h(-1)) after a loading dose (400 mg).

  19. Determination of triazine herbicides in milk by cloud point extraction and high-performance liquid chromatography.

    Science.gov (United States)

    Liu, Tiantian; Cao, Peng; Geng, Jinpei; Li, Jinqiang; Wang, Mingzhen; Wang, Minglin; Li, Xiaoyu; Yin, Dalu

    2014-01-01

    High-performance liquid chromatography with UV detection was used to detect four triazines in milk. An efficient pretreatment method known as cloud point extraction (CPE) was proposed for extracting and preconcentrating analytes. The parameters of CPE including surfactant type and concentration, electrolyte, sample pH, incubation temperature and duration were investigated. Under optimal conditions, satisfying recoveries in the range of 70.5-96.9% were achieved for four triazines. The limits of detection ranged from 6.79 to 11.19μg L(-1). The linear range of quantitation for the four triazines was 50-2000μg L(-1), and the correlation coefficients of the calibration curves were all 0.9999. The results demonstrated that the proposed method was efficient and reliable for the determination of triazine herbicides in milk samples.

  20. Development of High Performance Liquid Chromatography and Mass Spectrometry:a Key Engine of TCM Modernization

    Institute of Scientific and Technical Information of China (English)

    Zheng-Xiang Zhang; Xue Qiao; Min Ye; Man-Yu Zhang; Yue Song; Tao Bo

    2015-01-01

    Traditional Chinese Medicine (TCM) has been popular for thousand years in prevention and treatment of chronic diseases synergistically with Western medicine while producing mild healing effects and lower side effects. Although many TCMs have been proven effective by modern pharmacological studies and clinical trials, their bioactive constituents and the remedial mechanisms are still not well understood. Researchers have made great efforts to explore the real theory of TCM for many years with different strategies. Development of high performance liquid chromatography (HPLC) and mass spectrometry within recent decade can provide scientists with robust technologies for disclosing the mysterious mask of TCM. In this paper, important innovations of HPLC and mass spectrometry are reviewed in the application of TCM analysis from single compound identification to metabolomic strategy.

  1. High-performance liquid chromatographic determination of alpha-tocopherol in macroalgae.

    Science.gov (United States)

    Sánchez-Machado, D I; López-Hernández, J; Paseiro-Losada, P

    2002-11-08

    A high-performance liquid chromatographic (HPLC) method for the microscale determination of alpha-tocopherol in macroalgae is reported. The method includes microscale saponification and extraction with n-hexane. The presence of alpha-tocopherol in macroalgae samples was confirmed by HPLC-MS. Alpha-tocopherol levels as determined in samples by HPLC with UV and fluorescence detection did not differ significantly; however, fluorescence detection has a higher sensitivity (detection limit 10.4 ng/ml, vs. 104 ng/ml with UV detection), as well as good precision (relative standard deviation 1.81%) and recovery (94.3%). Fluorescence detection is also faster. We used this method to determine the alpha-tocopherol contents of four commercial macroalgae products from northwest Spain as part of nutritional studies in dehydrated Himanthalia elongata and Laminaria ochroleuca, and also in canned Himanthalia elongata and Saccorhiza polychides.

  2. High-Performance Liquid Chromatographic Method for Determination of Germacrone in Rat Plasma

    Institute of Scientific and Technical Information of China (English)

    HEHai-bing; TANGXing; CUIFu-de

    2004-01-01

    Aim A reliable high-performance liquid chromatographic (HPLC) method was developed for determination of gennacrone in rat. plasma. Methods The plasma samples were treated with acetonitrile and analyzed by HPLC with UV detection at 244 nm. Results The limit of detection was 100 ng·mL-1 for germacrone in plasma and the linear range was0.1004-15.06μg· mL-1 in plasma. The RSD of intra-day and inter-day assay was 1.87%-4.29% and 1.29%-5.15%, respectively. The recoveries of germacrone were over 95%. The endogenous substances in plasma did not show any interference in the analysis. Conclusion The method is accurate and convenient, and suitable for pharmacokinetic studies of gennacrone in rats.

  3. Detection of cheese whey and caseinomacropeptide in fermented milk beverages using high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    E.H.P. Andrade

    2014-06-01

    Full Text Available Cheese whey level and caseinomacropeptide (CMP index of fermented milk beverages added with four levels of cheese whey (0, 10, 20, and 40% and stored at 8-10oC for 0, 7, 14 and 21 days were determined by high performance liquid chromatography-gel filtration (HPLC-GF. Additionally, the interference of the starter culture and the storage time on the detection of cheese whey and CMP were investigated. Refrigerated storage up to 21 days did not affect (P>0.05 cheese whey and CMP amounts in milk (0% of cheese whey and in fermented milk beverages added with 10 and 20% of cheese whey (P>0.05. However, cheese whey and CMP amounts were higher than expected (P<0.05 in fermented milk beverages added with 40% of cheese whey and stored for 21 days.

  4. Tritium isotope effect in high-performance liquid chromatography of eicosanoids

    Energy Technology Data Exchange (ETDEWEB)

    Do, U.H.; Lo, S.-L.; Iles, J.; Rosenberger, T.; Tam, P.; Hong, Y.; Ahern, D. [DuPont, NEN Products, Boston (United States). Lipids Group

    1994-07-01

    A significant difference in retention time between unlabeled and the corresponding multi-tritium-labeled eicosanoid has been observed in the high performance liquid chromatography (HPLC) analysis of 11 eicosanoids. Variations in retention time range from 3-7%, depending on the separation conditions as well as the number and position of the tritium substitution. Multi-tritium-labeled eicosanoids were eluted earlier than the corresponding unlabeled eicosanoid in reversed phase HPLC, whereas no isotope effect was seen with {sup 14}C- and {sup 3}H{sub 2}-eicosanoids. Considerations must be given to this tritium isotope effect whenever both multi-tritium-labeled and unlabeled eicosanoids are used for HPLC cochromatography or recovery studies. (author).

  5. High-performance liquid chromatography determination of dapsone, monoacetyldapsone, and pyrimethamine in filter paper blood spots

    DEFF Research Database (Denmark)

    Rønn, A M; Lemnge, M M; Angelo, H R

    1995-01-01

    A high-performance liquid chromatography method for the simultaneous analysis of dapsone (DDS), the major metabolite of DDS, monoacetyldapsone (MADDS), and pyrimethamine (PYR) was modified for capillary blood samples obtained by finger prick and dried on filter paper. Limit of quantitation using...... 150 microliters whole blood dried on filter paper was found to be 20 ng/ml for DDS and PYR and 15 ng/ml for MADDS (precision ... paper method and the original whole-blood method was almost comparable. Standardization could therefore be obtained by the more simple whole-blood method. Dried filter paper samples stored at 19-22 degrees C were stable for months and for 2 weeks stored at 35 degrees C. The concentrations...

  6. Determination of primary amino acids in wines by high performance liquid magneto-chromatography.

    Science.gov (United States)

    Barrado, E; Rodriguez, J A; Castrillejo, Y

    2009-05-15

    Eight amino acids (ethanolamine, glycine, alanine, beta-aminobutyric acid, leucine, methionine, histidine and asparagine) were identified and quantified in Spanish wines by high performance liquid magneto-chromatography (HPLMC) with UV-V spectrophotometry. For this method, the amino acids are first complexed with mono(1,10-phenanthroline)-Cu(II) to confer them paramagnetic properties, and then separated by application of a low magnetic field intensity (5.5 mT) to the stationary phase contained in the chromatographic column. Principal components analysis of the results obtained grouped together the wine samples according to their denomination of origin: "Ribera del Duero", "Rueda" or "Rioja" (Spain). Through cluster analysis, a series of correlations was also observed among certain amino acids, and between these groupings and the type of wine. These clusters were found to reflect the role played by the amino acids as primary or secondary nutrients for the bacteria involved in alcoholic and malolactic fermentation.

  7. Rocket-powered high-performance liquid chromatographic analysis of plant ascorbate and glutathione.

    Science.gov (United States)

    Davey, M W; Dekempeneer, E; Keulemans, J

    2003-05-01

    We describe a robust procedure for the extraction and high-performance liquid chromatographic analysis of L-ascorbate (vitamin C), glutathione (gamma-glutamyl cysteinylglycine), and their respective oxidized forms from various plant tissues. Parameters such as the choice of extraction buffer, tissue disruption technique, sample stability, and separation conditions have all been optimized. In particular we found that the inclusion of the reducing agent dithiothreitol as a "stabilizer" in extracts with high phenolic content actually promoted oxidation of these antioxidants. Further, by using commercially available short "Rocket" HPLC columns in combination with high mobile-phase flow rates, analysis times were reduced to only 6min, making the method suitable for the high-resolution screening of large numbers of samples.

  8. Development of high performance liquid chromatography method for miconazole analysis in powder sample

    Science.gov (United States)

    Hermawan, D.; Suwandri; Sulaeman, U.; Istiqomah, A.; Aboul-Enein, H. Y.

    2017-02-01

    A simple high performance liquid chromatography (HPLC) method has been developed in this study for the analysis of miconazole, an antifungal drug, in powder sample. The optimized HPLC system using C8 column was achieved using mobile phase composition containing methanol:water (85:15, v/v), a flow rate of 0.8 mL/min, and UV detection at 220 nm. The calibration graph was linear in the range from 10 to 50 mg/L with r 2 of 0.9983. The limit of detection (LOD) and limit of quantitation (LOQ) obtained were 2.24 mg/L and 7.47 mg/L, respectively. The present HPLC method is applicable for the determination of miconazole in the powder sample with a recovery of 101.28 % (RSD = 0.96%, n = 3). The developed HPLC method provides short analysis time, high reproducibility and high sensitivity.

  9. High-performance liquid chromatography for determination of α-tocopherol in vegetables

    Directory of Open Access Journals (Sweden)

    Marcin Horbowicz

    2013-12-01

    Full Text Available A simple method for the determination of α-tocopherol in vegetables is described. The procedure consists of the following steps: saponification, extraction, silica-column clean-up, and high-performance liquid chromatography. Elution time for D, L-α-tocopherol was 9.0 min using a Zorbax Sil (250 x 4.6 mm column and an isocratic mobile phase of hexane-methanol (99.3 + 0.7, with a flow rate of 1 ml/min, and detection at 292 nm using a variable UV detector. The average recovery of α-tocopherol was 91.2%, and the minimum detectable amount was 0.1 mg/100 g of fresh vegetable tissue. This method is comparable to gas-chromatographic determination of α-tocopherol, but has fewer analytical steps and gives more reproducible results.

  10. High-performance liquid chromatographic determination of vertilmicin in rat plasma using sensitive fluorometric derivatization.

    Science.gov (United States)

    Liu, Zhen; Sha, Yunfei; Huang, Taomin; Yang, Bei; Duan, Geng-Li

    2005-12-15

    A sensitive and reliable high-performance liquid chromatographic method was developed for the determination of vertilmicin in rat plasma. Derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) followed by C(18) reversed-phase chromatography allowed the fluorimetric detection of vertilmicin. Optimal conditions for the derivatization of vertilmicin are described. The limit of quantification was 0.02 mg/L. The pharmacokinetics of vertilmicin was studied in 24 rats following intramuscular injection (i.m.) of different doses (4, 8, 16, 32 mg/kg of body weight). The pharmacokinetic parameter values were estimated by use of 3P97 program. In this study, we assessed the dose proportionality of vertilmicin after single intramuscular injection doses and obtained new information on the pharmacokinetics of the compound.

  11. Determination of artificial sweeteners in beverages and special nutritional products using high performance liquid chromatography.

    Science.gov (United States)

    Serdar, Maja; Knežević, Zorka

    2011-06-01

    This paper presents two high performance liquid chromatographic (HPLC) methods used for the separation and determination of artificial sweeteners aspartame, acesulphame K, sodium saccharin, and sodium cyclamate in beverages and special nutritional products (special food intended for specific population groups). All four compounds are soluble in aqueous solutions and can easily be separated and determined by HPLC with a diode array detector (DAD). The first method involved separation of aspartame, acesulphame K, and sodium saccharin on a C18 column with an isocratic elution of phosphate buffer and acetonitrile as mobile phase. The second method was used to separate sodium cyclamate on a C18 column with methanol and water as mobile phase. Under optimum conditions, both methods showed good analytical performance, such as linearity, precision, and recovery. The methods were successfully applied for the analysis of real samples of soft drinks and special nutritional products.

  12. Quantitative determination of acetaminophen, phenylephrine and carbinoxamine in tablets by high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Carina de A. Bastos

    2009-01-01

    Full Text Available An alternative methodology for analysis of acetaminophen (Ace, phenylephrine (Phe and carbinoxamine (Car in tablets by ion-pair reversed phase high performance liquid chromatography was validated. The pharmaceutical preparations were analyzed by using a C18 column (5 μm, 300 mm, 3.9 mm and mobile phase consisting of 60% methanol and 40% potassium monobasic phosphate aqueous solution (62.46 mmol L-1 added with 1 mL phosphoric acid, 0.50 mL triethylamine and 0.25 g sodium lauryl sulfate. Isocratic analysis was performed under direct UV detection at 220 nm for Phe and Car and at 300 nm for Ace within 5 min.

  13. High Performance Liquid Chromatography of the Dansyl Derivatives of Putrescine, Spermidine, and Spermine 1

    Science.gov (United States)

    Escribano, M. Isabel; Legaz, M. Estrella

    1988-01-01

    A high performance liquid chromatographic (HPLC) method, based on dansylation and fluorescence detection, is described for the estimation of putrescine, spermidine, and spermine in lichen (Evernia prunastri [L.]) samples. Because of the high concentrations of phenols and salts, dansylation was followed by a pre-HPLC purification step. Both flow rate and mobile phase (methanol:water) followed a gradient for optimum resolution on a reverse-phase column. Amounts as small as 0.3 picomole of standard polyamines could be detected. In applying the method to lichens, it was found that 5.45% (w/w) of the exogenous putrescine taken up by the thallus was unbound in the algal partner and that 60% (w/w) was conjugated in the thallus, perhaps to lichen phenolics. PMID:16666175

  14. High performance liquid chromatography of the dansyl derivatives of putrescine, spermidine, and spermine.

    Science.gov (United States)

    Escribano, M I; Legaz, M E

    1988-06-01

    A high performance liquid chromatographic (HPLC) method, based on dansylation and fluorescence detection, is described for the estimation of putrescine, spermidine, and spermine in lichen (Evernia prunastri [L.]) samples. Because of the high concentrations of phenols and salts, dansylation was followed by a pre-HPLC purification step. Both flow rate and mobile phase (methanol:water) followed a gradient for optimum resolution on a reverse-phase column. Amounts as small as 0.3 picomole of standard polyamines could be detected. In applying the method to lichens, it was found that 5.45% (w/w) of the exogenous putrescine taken up by the thallus was unbound in the algal partner and that 60% (w/w) was conjugated in the thallus, perhaps to lichen phenolics.

  15. High-performance liquid chromatographic assay detects pentamidine metabolism by Fisher rat liver microsomes.

    Science.gov (United States)

    Tuttle, R H; Hall, J E; Tidwell, R R

    1997-01-24

    Fisher rat liver microsomes metabolized the antimicrobial drug pentamidine to four new compounds detected by gradient elution reversed-phase high-performance liquid chromatography with variable wavelength detection. Coelution experiments with pentamidine metabolite standards determined the new peaks to be previously identified hydroxylated metabolites of pentamidine, with 1,5-bis(4'-amidinophenoxy)-3-pentanol and 1,5-di-(4'-amidinophenoxy)-2-pentanol formed in the greatest amount. The data contradict a previous report that Fisher rat liver homogenates do not metabolize pentamidine. Pentamidine and its known primary metabolites have almost identical absorption spectra; thus, pentamidine metabolism must be evaluated using gradient elution HPLC to resolve pentamidine from its metabolites. The current assay has now been used to demonstrate that Fisher and Sprague-Dawley rat, mouse, rabbit and human liver microsomes all metabolize pentamidine in vitro.

  16. DETERMINATION OF FLUCONAZOLE IN HUMAN PLASMA BY REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY.

    Science.gov (United States)

    Safaei, Zahra; Alipour, Eskandar; Shafaati, Alireza; Zarghp, Afshin

    2015-01-01

    A rapid, simple and reproducible high performance liquid chromatographic method was developed and validated for determination of fluconazole in human plasma. The separation was performed on MZ C8 column (125 x 4 mm, 5 µm) using acetonitrile - potassium dihydrogen phosphate buffer (15 : 85, v/v), pH 3.0, as the mobile phase at a flow rate of 1.5 mL/min. The wavelength was set at 261 nm. The assay enables the measurement of fluconazole for therapeutic drug monitoring with a minimum quantification limit of 20 ng/mL. The method involves simple, protein precipitation procedure and analytical recovery was complete. The calibration curve was linear over the concentration range 0.1-4 µg/mL. The coefficients of variation for inter-day and intra-day assay were found to be less than 10%.

  17. Microwave-assisted ionic liquid homogeneous liquid-liquid microextraction coupled with high performance liquid chromatography for the determination of anthraquinones in Rheum palmatum L.

    Science.gov (United States)

    Wang, Zhibing; Hu, Jianxue; Du, Hongxia; He, Shuang; Li, Qing; Zhang, Hanqi

    2016-06-01

    The microwave-assisted ionic liquid homogeneous liquid-liquid microextraction (MA-IL-HLLME) coupled with high performance liquid chromatography with diode array detection (HPLC-DAD) was developed for the determination of anthraquinones, including aloe-emodin, emodin, chrysophanol and physcion in root of Rheum palmatum L. Several experimental parameters influencing the extraction efficiency, including amount of sample, type and volume of ionic liquid, volume and pH value of extraction medium, microwave power and extraction time, concentration of NH4PF6 as well as centrifugal condition were optimized. When 140μL of ionic liquid ([C8MIM][BF4]) was used as an extraction solvent, target analytes can be extracted from sample matrix in one minute with the help of microwave irradiation. The MA-IL-HLLME is simple and quick. The calibration curves exhibited good linear relationship (r>0.9984). The limits of detection and quantification were in the range of 0.015-0.026 and 0.051-0.088μgmL(-1), respectively. The spiked recovery for each analyte was in the range of 81.13-93.07% with relative standard deviations lower than 6.89%. The present method is free of volatile organic solvents, and represents lower expenditures of sample, extraction time and solvent, compared with ultrasonic and heat reflux extraction. The results indicated that the present method can be successfully applied to the determination of anthraquinones in medicinal plant.

  18. [Determination of five triazine herbicides in infant milk powder by high performance liquid chromatography coupled with ionic liquid-based homogeneous liquid-liquid microextraction].

    Science.gov (United States)

    Zhang, Liyuan; Yao, Di; Li, Na; Zhang, Hanqi; Yu, Aimin

    2015-07-01

    A high performance liquid chromatography coupled with homogeneous liquid-liquid microextraction was developed for the determination of five triazine herbicides in infant milk powders. The ionic liquid was used as microextraction solvent. The separation of the herbicides was performed on an Eclipse XDB-C18 column using acetonitrile and water as mobile phases in gradient mode. The effects of homogeneous liquid-liquid extraction conditions on the experimental results were investigated in detail. Under the optimized experimental conditions, the calibration curves for determining the analytes were linear and the correlation coefficients were ≥ 0.9992. The limits of detection for cyanazine, desmetryn, terbumeton, terbuthylazine and dimethametryn were 12.1, 13.8, 11.8, 14.6 and 13.7 μg/kg, respectively. The recoveries of the analytes spiked in four infant milk powders ranged from 92.2% to 103.2% and the relative standard deviations were lower than 6%. This method is sensitive, simple, and suitable for the determination of triazine herbicides in milk powder samples.

  19. Cobalamin Concentrations in Fetal Liver Show Gender Differences: A Result from Using a High-Pressure Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry as an Ultratrace Cobalt Speciation Method.

    Science.gov (United States)

    Bosle, Janine; Goetz, Sven; Raab, Andrea; Krupp, Eva M; Scheckel, Kirk G; Lombi, Enzo; Meharg, Andrew A; Fowler, Paul A; Feldmann, Jörg

    2016-12-20

    Maternal diet and lifestyle choices may affect placental transfer of cobalamin (Cbl) to the fetus. Fetal liver concentration of Cbl reflects nutritional status with regards to vitamin B12, but at these low concentration current Cbl measurement methods lack robustness. An analytical method based on enzymatic extraction with subsequent reversed-phase-high-pressure liquid chromatography (RP-HPLC) separation and parallel ICPMS and electrospray ionization (ESI)-Orbitrap-MS to determine specifically Cbl species in liver samples of only 10-50 mg was developed using 14 pig livers. Subsequently 55 human fetal livers were analyzed. HPLC-ICPMS analysis for cobalt (Co) and Cbl gave detection limits of 0.18 ng/g and 0.88 ng/g d.m. in liver samples, respectively, with a recovery of >95%. Total Co (Cot) concentration did not reflect the amount of Cbl or vitamin B12 in the liver. Cbl bound Co contributes only 45 ± 15% to Cot. XRF mapping and μXANES analysis confirmed the occurrence of non-Cbl cobalt in pig liver hot spots indicating particular Co. No correlations of total cobalt nor Cbl with fetal weight or weeks of gestation were found for the human fetal livers. Although no gender difference could be identified for total Co concentration, female livers were significantly higher in Cbl concentration (24.1 ± 7.8 ng/g) than those from male fetuses (19.8 ± 7.1 ng/g) (p = 0.04). This HPLC-ICPMS method was able to quantify total Cot and Cbl in fetus liver, and it was sensitive and precise enough to identify this gender difference.

  20. Flavonoid profiling of a traditional Chinese medicine formula of Huangqin Tang using high performance liquid chromatography

    Science.gov (United States)

    Li, Tao; Zhuang, Shuaixing; Wang, Yiwei; Wang, Yanli; Wang, Weihao; Zhang, Huihui; Chen, Li; Wang, Dunfang; Zhou, Zhongming; Yang, Weipeng

    2016-01-01

    The quality control processes for herbal medicines have been problematic. Flavonoids are the major active components of Huangqin Tang (HQT, a traditional Chinese medicine formula). In this study, we used a combinative method approach consisting of chromatographic fingerprinting (high performance liquid chromatography; HPLC), quantitative methods and a pharmacodynamic evaluation model to analyze the flavonoids of HQT obtained from different sources. Ten batches of HQT were analyzed by the HPLC fingerprinting method and 26 common peaks were detected, of which 23 peaks corresponded with the chemical profile of HQT. In addition, 11 major compounds were identified by LC–MS analysis (liquid chromatography–tandem mass spectrometer; LC–MSn) and quantified by the HPLC quantitative method approach. The studied 10 batches of HQT were found to be homogeneous in their composition with a similarity between 0.990 and 1.000. The distribution of the 11 identified compounds was found to be very similar among the batches. Only slight pharmacodynamic differences were detected between the different batches, confirming the homogeneity of HQT. The results of this study prove that the combination of chromatographic fingerprinting and quantitative analysis can be readily used for comprehensive quality control of herbal medicines. PMID:27006899

  1. Fully automated high-performance liquid chromatographic assay for the analysis of free catecholamines in urine.

    Science.gov (United States)

    Said, R; Robinet, D; Barbier, C; Sartre, J; Huguet, C

    1990-08-24

    A totally automated and reliable high-performance liquid chromatographic method is described for the routine determination of free catecholamines (norepinephrine, epinephrine and dopamine) in urine. The catecholamines were isolated from urine samples using small alumina columns. A standard automated method for pH adjustment of urine before the extraction step has been developed. The extraction was performed on an ASPEC (Automatic Sample Preparation with Extraction Columns, Gilson). The eluate was collected in a separate tube and then automatically injected into the chromatographic column. The catecholamines were separated by reversed-phase ion-pair liquid chromatography and quantified by fluorescence detection. No manual intervention was required during the extraction and separation procedure. One sample may be run every 15 min, ca. 96 samples in 24 h. Analytical recoveries for all three catecholamines are 63-87%, and the detection limits are 0.01, 0.01, and 0.03 microM for norepinephrine, epinephrine and dopamine, respectively, which is highly satisfactory for urine. Day-to-day coefficients of variation were less than 10%.

  2. [Measurement of 11 benzophenone ultraviolet-filters in cosmetics by high performance liquid chromatography].

    Science.gov (United States)

    Qu, Baocheng; Bian, Haitao; Mao, Xiqin; Li, Jin

    2015-12-01

    A sample preparation and analytical method with liquid-liquid extraction (LLE) and high performance liquid chromatography (HPLC) was developed to detect 11 benzophenone ultraviolet-filters in cosmetics. The target compounds were extracted by the mixed solutions of tetrahydrofuran (TH)/methanol/water or dichloromethane/water at proper ratios. The extracts were centrifuged and filtered to remove matrix compounds, and then analyzed by HPLC. The separation of analytes was carried out on a Diamonsil-C18 column (150 mm x 4.6 mm, 5 μm) with 0.1% (v/v) formic acid aqueous solution (containing 10 mmol/L ammonium acetate) as mobile phase A and methanol containing 0.1% (v/v) formic acid as mobile phase B. The spiked recoveries of the method (n = 7) were 93.4%-103.8% with the relative standard deviations of 0.1%-4.2%. The limits of detection (LODs) were in the range of 4.0-30 μg/g and the limits of quantitation (LOQs) ranged from 15 to 100 μg/g. The method was applied to the determination of 42 cosmetic samples randomly purchased from the supermarket in Dalian. Five benzophenone series were always detected, in which the content of benzophenone-3 in sunscreen cream and the content of benzophenone-2 in perfume were very high and reached 2 785 μg/g and 2 106 μg/g, respectively. The results showed that the developed method is efficient, reliable and sensitive, which can be applied to the determination of benzophenones in cosmetics.

  3. Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ovchinnikova, Olga S [ORNL; Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

    2011-01-01

    This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of this coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.

  4. Quantitative Analysis of Sphingomyelin by High-Performance Liquid Chromatography after Enzymatic Hydrolysis

    Directory of Open Access Journals (Sweden)

    Seunghyun Lee

    2012-01-01

    Full Text Available Sphingomyelin is the most abundant sphingolipid in mammalian cells and is mostly present in the plasma membrane. A new analytical method using high-performance liquid chromatography (HPLC was developed to quantify sphingomyelin in mouse plasma and tissues, 3T3-L1 cells, rat aortic smooth muscle cells, and HT-29 cells. Sphingomyelin and dihydrosphingomyelin, an internal standard, were separated by high-performance thin-layer chromatography and simultaneously hydrolyzed with sphingolipid ceramide N-deacylase and sphingomyelinase to release sphingosine and dihydrosphingosine, respectively. Sphingomyelin content was measured by HPLC following o-phthalaldehyde derivatization. Sphingomyelin concentrations in 3T3-L1 cells, rat aortic smooth muscle cells, and HT-29 cells were 60.10±0.24, 62.69±0.08, and 58.38±0.37 pmol/μg protein, respectively, whereas those in brain, kidney, and liver of ICR mice were 55.60±0.43, 43.75±0.21, and 22.26±0.14 pmol/μg protein. The sphingomyelin concentration in mouse plasma was 407.40±0.31 μM. The limits of detection and quantification for sphingomyelin were 5 and 20 pmol, respectively, in the HPLC analysis with fluorescence detection. This sensitivity was sufficient for analyzing sphingomyelin in biological samples. In conclusion, this analytical method is a sensitive and specific technique for quantifying sphingomyelin and was successfully applied to diverse biological samples with excellent reproducibility.

  5. Ionic Liquid-based Microwave-assisted Liquid-liquid Microextraction and High Performance Liquid Chromatography Determination of Sulfonamides from Animal Oils

    Institute of Scientific and Technical Information of China (English)

    FENG Xu-dong; LIANG Fang-hui; SU Rui; WU Li-jie; LI Xue-yuan; WANG Xing-hua; ZHANG Han-qi

    2013-01-01

    The authors performed ionic liquid-based microwave-assisted liquid-liquid microextraction(IL-based MALLME) coupled with high performance liquid chromatographic separation for the determination of 6 sulfonamides (SAs) from animal oils.The target analytes were extracted from animal oil samples with sodium hydroxide solution containing 1-butyl-3-methylimidazolium tetrafluoroborateand as the extraction solvent under microwave irradiation.The experimental parameters of the IL-based MALLME,including types of ILs,volume of IL,amount of ion-pairing agent(NH4PF6),pH value of sample solution,and extraction temperature and time were evaluated.The limits of detection and quantification obtained were in a range of 0.4-0.5 μg/kg and a range of 1.2-1.8 μg/kg,respectively.The accuracy of the method was evaluated by analyzing five spiked animal oil samples at two fortified levels(5 and 50 μg/kg),and the recoveries of SAs varied from 81.4% to 114.5% with relative standard deviations ranging from 0.8% to 9.0%.

  6. Quantitation of antioxidants in water samples using ionic liquid dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-ultraviolet detection.

    Science.gov (United States)

    Sobhi, Hamid Reza; Kashtiaray, Amir; Farahani, Hadi; Farahani, Mohammad Reza

    2011-01-01

    A simple and efficient method, ionic liquid-based dispersive liquid-liquid microextraction combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV), has been applied for the extraction and determination of some antioxidants (Irganox 1010, Irganox 1076 and Irgafos 168) in water samples. The microextraction efficiency factors were investigated and optimized: 1-hexyl-3-methylimidazolium hexafluorophosphate [C(6)MIM][PF(6)] (0.06 g) as extracting solvent, methanol (0.5 mL) as disperser solvent without salt addition. Under the selected conditions, enrichment factors up to 48-fold, limits of detection (LODs) of 5.0-10.0 ng/mL and dynamic linear ranges of 25-1500 ng/mL were obtained. A reasonable repeatability (RSD≤11.8%, n=5) with satisfactory linearity (r(2)≥0.9954) of the results illustrated a good performance of the presented method. The accuracy of the method was tested by the relative recovery experiments on spiked samples, with results ranging from 85 to 118%. Finally, the method was successfully applied for determination of the analytes in several real water samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Evaluation of aminoacids in irradiated beans (Vigna unguiculata (L.) Walp) by high performance liquid chromatography (HPLC)

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Keila S. Cople; Souza, Luciana B.; Coelho, Maysa J.; Lima, Antonio L. Santos; Hernandes, Nilber K. [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Secao de Engenharia Nuclear]. E-mail: keila@ime.eb.br; Godoy, Ronoel L.O. [EMBRAPA Agroindustria de Alimentos, Rio de Janeiro, RJ (Brazil)]. E-mail: ronoel@ctaa.embrapa.br

    2007-07-01

    Fradinho-bean (Vigna unguiculata (L.) Walp) is originated from Africa and is known in Brazil as 'caupi', 'corda' or 'macassar'. It is grown in the interior of Northeast Brazil (semi-arid region) and can be found in parts of the North, being one of the most important components of people's diet in those regions. The Northeast area produces around 429,375 ton of fradinho-bean per year. Leguminous plants are very important sources of proteins, vitamins, carbohydrates and minerals. This kind of bean is an excellent source of proteins (around 23- 25% of its nutritional content), being superior to regular beans (Phaseolus vulgaris). The irradiation process is an alternative to avoid post-harvesting losses, without changing the nutritional value of food. This study has the objective to evaluate the effect of different gamma irradiation doses (0.0; 0.5; 1.0; 2.5; 5.0 and 10.0 kGy) on aminoacid content of fradinho-bean by high performance liquid chromatography (HPLC) and the accompanying of the grains during storage time of 6 months. After irradiation, the bean grains went through a milling process in order to make flour for posterior extraction. A liquid chromatographer Waters, model Alliance 2695, with fluorescent detector Waters 2475, having a mobile phase with gradient elution of sodium acetate. acetonitrile and Milli-Q water, was employed. The flux used was 1 mL/min and the injection volume of 10 {mu}L. The column (C 18 150.0 x 3.9 mm) was kept at 36 deg C. The results show that gamma irradiation is a promise process for fradinho bean during conservation storage time of 6 months, until the dose of 10.0 kGy. Even the most radio-sensitive aminoacids like aromatics and basic lateral chains were preserved. (author)

  8. High-performance liquid chromatography determination of dipotassium clorazepate and its major metabolite nordiazepam in plasma.

    Science.gov (United States)

    Colin, P; Sirois, G; Lelorier, J

    1983-04-08

    A rapid and sensitive high-performance liquid chromatographic method is described for the quantitative analysis of dipotassium clorazepate (CZP) and its major metabolite nordiazepam (ND) in fresh human and dog plasma. The method consists of two separate selective ND extractions from a plasma sample without and with conversion of all the CZP to ND. For quantitation, diazepam (DZP) is used as the internal standard. The chromatographic phase utilized in a reversed-phase Hibar EC-RT analytical column prepacked with LiChrosolv RP-18 with a solvent system consisting of acetonitrile-0.05 M sodium acetate buffer, pH 5.0 (45:55). The UV absorbance is monitored at 225 nm using a variable-wavelength detector. The mean assay coefficient of variation over a concentration range of 20-400 ng per ml of plasma is less than 3% for the within-day precision. Recoveries of ND, DZP and CZP (as ND) are essentially quantitative at all levels investigated. The calibration curves of ND are rectilinear (r2 = 0.99) from the lower limit of sensitivity (2 ng/ml) to at least 2000 ng/ml in plasma. Applicability of the method to CZP and ND disposition studies in the anaesthetized mongrel dog is illustrated. When the two separate selective nordiazepam extractions from plasma cannot be performed immediately after blood sampling, an extrapolation kinetic method is suggested for the estimation of CZP concentration. In all previous in vivo studies, CZP has been determined only with gas-liquid chromatographic methods.

  9. Simultaneous determination of tolperisone and lidocaine by high performance liquid chromatography.

    Science.gov (United States)

    Liawruangrath, S; Liawruangrath, B; Pibool, P

    2001-12-01

    A reversed phase high performance liquid chromatographic (RP-HPLC) method for the simultaneous determination of tolperisone (TP) and lidocaine (LD) has been developed. The drugs were separated on a column (4.60 x 250 mm(2)) Spherisorb ODS (5 microm) using 5.5% triethylamine in 70/30 v/v acetonitrile/water as mobile phase 0.7 ml min(-1)and UV detection at 254 nm. The detection limits for Tolperisone hydrochloride (TP-HCl) and lidocaine hydrochloride (LD-HCl) were 0.20 ng/20 microl and 100 ng/20 microl and the quantitation limits were 0.50 ng/20 microl and 250 ng/20 microl, respectively. Linear calibration curves over the ranges of 1-10, 10-100 and 150-500 microg ml(-1) for TP-HCl and 10-500 microg ml(-1) for LD-HCl were established. Different calibration slopes were found for TP probably owing to changes in refractive index due to increase in TP concentration. The average recoveries of the added TP in the samples (TP-HCl tablets and injection liquid). A solutions spiked with standard TP-HCl were 99.9 and 99.7% with the RSD (n=11) of 0.66 and 0.67%, respectively. The average recovery of the added LD in the sample (injection) spiked with standard LD-HCl was 98.9% with the RSD (n=11) of 0.59%. The proposed method has been applied to the determination of TP-HCl and LD-HCl in commercial products available in Thailand. Comparative determination of TP by UV spectrophotometry and LD by colorimetry were also carried out. The results obtained by both methods were in good agreement of those obtained by the proposed method verified by using t-test. The proposed RP-HPLC method is simple, accurate, reproducible and suitable for routine analysis.

  10. Determination of diflubenzuron and chlorbenzuron in fruits by combining acetonitrile-based extraction with dispersive liquid-liquid microextraction followed by high-performance liquid chromatography.

    Science.gov (United States)

    Ruan, Chunqiang; Zhao, Xiang; Liu, Chenglan

    2015-09-01

    In this study, a simple and low-organic-solvent-consuming method combining an acetonitrile-partitioning extraction procedure followed by "quick, easy, cheap, effective, rugged and safe" cleanup with ionic-liquid-based dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection was developed for the determination of diflubenzuron and chlorbenzuron in grapes and pears. Ionic-liquid-based dispersive liquid-liquid microextraction was performed using the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate as the extractive solvent and acetonitrile extract as the dispersive solvent. The main factors influencing the efficiency of the dispersive liquid-liquid microextraction were evaluated, including the extractive solvent type and volume and the dispersive solvent volume. The validation parameters indicated the suitability of the method for routine analyses of benzoylurea insecticides in a large number of samples. The relative recoveries at three spiked levels ranged between 98.6 and 109.3% with relative standard deviations of less than 5.2%. The limit of detection was 0.005 mg/kg for the two insecticides. The proposed method was successfully used for the rapid determination of diflubenzuron and chlorbenzuron residues in real fruit samples.

  11. [Determination of polyphenols in tobacco by solid phase extraction and high performance liquid chromatography].

    Science.gov (United States)

    Wang, L; Fang, R B; Li, Z; Jiang, C Q; Yang, G Y

    2001-11-01

    A high performance liquid chromatographic (HPLC) method for the determination of polyphenols in tobacco was studied. Polyphenols can be extracted from tobacco sample by refluxing with 80% (volume fraction) methanol, then subjected to degrease by solid phase extraction with Sep-Pak-C18 column. Chlorogenic acid, rutin, scopoletin, caffeic acid, scopolin and other polyphenols can be separated on a Nova-Pak-C18 column (3.9 mm i.d. x 150 mm) gradiently eluted with methanol and 0.05 mol.L-1 potassium dihydrogen phosphate buffer solution as mobile phase at a flow-rate of 0.5 mL.min-1. Polyphenols were determined at the maximum wavelength of each polyphenol, for chlorogenic acid 326.1 nm, rutin 354.8 nm, scopoletin 344.0 nm, caffeic acid 323.7 nm and scopolin 365.2 nm by photodiode array detector. The main polyphenols in tobacco can be identified with UV spectroscopy. The recoveries of tobacco polyphenols were 94%-105%, and the relative standard deviations were 1.28%-1.49%. This method can be applied to the determination of polyphenols in tobacco with satisfactory results.

  12. High-performance liquid chromatographic assay for metamizol metabolites in rat plasma: application to pharmacokinetic studies.

    Science.gov (United States)

    Domínguez-Ramírez, Adriana Miriam; Calzadilla, Patricia Carrillo; Cortés-Arroyo, Alma Rosa; Hurtado Y de la Peña, Marcela; López, José Raúl Medina; Gómez-Hernández, Martín; López-Muñoz, Francisco Javier

    2012-12-01

    In order to evaluate the pharmacokinetics of metamizol in the presence of morphine in arthritic rats, after subcutaneous administration of the drugs, an easy, rapid, sensitive and selective analytical method was proposed and validated. The four main metamizol metabolites (4-methylaminoantipyrine, 4-aminoantipyrine, 4-acetylaminoantipyrine and 4-formylaminoantipyrine) were extracted from plasma samples (50-100μl) by a single solid-phase extraction method prior to reverse-phase high performance liquid chromatography with diode-array detection. Standard calibration graphs for all metabolites were linear within a range of 1-100μg/ml (r(2)≥0.99). The intra-day coefficients of variation (CV) were in the range of 1.3-8.4% and the inter-day CV ranged from 1.5 to 8.4%. The intra-day assay accuracy was in the range of 0.6-9.6% and the inter-day assay accuracy ranged from 0.9 to 7.5% of relative error. The lower limit of quantification was 1μg/ml for all metabolites using a plasma sample of 100μl. Plasma samples were stable at least for 4 weeks at -20°C. This method was found to be suitable for studying metamizol metabolites pharmacokinetics in arthritic rats, after simultaneous administration of metamizol and morphine, in single dose. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Determination of aristolochic acids by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Wang, Yinan; Chan, Wan

    2014-06-25

    Nephrotoxic and carcinogenic aristolochic acids (AAs) are naturally occurring nitrophenanthrene carboxylic acids in the herbal genus Aristolochia. The misuse of AA-containing herbs in preparing slimming drugs has caused hundred of cases of kidney disease in Belgium women in a slimming regime in the early 1990s. Accumulating evidence also suggested that prolong dietary intake of AA-contaminated food is one of the major causes to the Balkan endemic nephropathy that was first observed in the late 1950s. Therefore, analytical methods of high sensitivity are extremely important for safeguarding human exposure to AA-containing herbal medicines, herbal remedies, and food composites. In this paper, we describe the development of a new high-performance liquid chromatography coupled fluorescence detector (HPLC-FLD) method for the sensitive determination of AAs. The method makes use of a novel cysteine-induced denitration reaction that "turns on" the fluorescence of AAs for fluorometric detections. Our results showed that the combination of cysteine-induced denitration and HPLC-FLD analysis allows for sensitive quantification of AA-I and AA-II at detection limits of 27.1 and 25.4 ng/g, respectively. The method was validated and has been successfully applied in quantifying AAs in Chinese herbal medicines.

  14. Determination of 5-methylcytosine from plant DNA by high-performance liquid chromatography.

    Science.gov (United States)

    Wagner, I; Capesius, I

    1981-06-26

    The relative amounts of the five nucleosides (deoxycytidine, 5-methyldeoxycytidine, deoxyadenosine, deoxyguanosine and thymidine) in the DNA of nine plant species, one plant satellite DNA, and one animal species were determined by high performance liquid chromatography. The method allows the clean separation of the nucleosides from 10 microgram samples with 15 min. The following values for the proportion of methylated cytosines among all cytosines were obtained: Lobularia maritima 18.5%, Nicotiana tabacum 32.6%, Pisum sativum 23.2%, Rhinanthus minor 29.2%, Sinapsis alba 12.2%, Vicia faba 30.5%, Viscum album 23.2%, Cymbidium pumilum 18.8%, Cymbidium pumilum AT-rich satellite DNA 15.8%, Triticum aestivum 22.4%. DNA of an animal, the gerbil, Meriones unguiculatus, had a methylation percentage of 3.1%. An estimate of the GC content based on the buoyant density of DNA tends to be lower than the actual value, an estimate based on the melting temperature tends to be higher. This supports the finding by other authors that DNA methylation decreases the buoyant density and may increase the melting temperature at high m5C concentration.

  15. Rapid estimation of concentration of aromatic classes in middistillate fuels by high-performance liquid chromatography

    Science.gov (United States)

    Otterson, D. A.; Seng, G. T.

    1985-01-01

    An high performance liquid chromatography (HPLC) method to estimate four aromatic classes in middistillate fuels is presented. Average refractive indices are used in a correlation to obtain the concentrations of each of the aromatic classes from HPLC data. The aromatic class concentrations can be obtained in about 15 min when the concentration of the aromatic group is known. Seven fuels with a wide range of compositions were used to test the method. Relative errors in the concentration of the two major aromatic classes were not over 10 percent. Absolute errors of the minor classes were all less than 0.3 percent. The data show that errors in group-type analyses using sulfuric acid derived standards are greater for fuels containing high concentrations of polycyclic aromatics. Corrections are based on the change in refractive index of the aromatic fraction which can occur when sulfuric acid and the fuel react. These corrections improved both the precision and the accuracy of the group-type results.

  16. Reversed-phase high-performance liquid chromatography of unsubstituted aminobenzoic acids

    Science.gov (United States)

    Abidi, S.L.

    1989-01-01

    High-performance liquid chromatographic (HPLC) characteristics of three position isomers of aminobenzoic acids (potential metabolites of important anesthetic drugs), were delineated with respect to their interactions with various mobile phases and stationary phases. HPLC with five hydrocarbonaceous phase, I?-cyclodextrin silica (CDS), macrophase MP-1 polymer (MP), macroporous polystyrene/divinylbenzene (MPD), octadecylsilica (ODS), and propylphenylsilica (PPS), yielded results explicable in terms of substituent effects derived from the bifunctional amino- and carboxy groups. For cases where mobile phases contained sulfonates or quaternary ammonium salts both having longer chain alkyls, retention of analytes on all but CDS appeared to proceed predominantly via an ion-pairing mechanism. The extent of the corresponding counter-ion effects decreased in the order: MPD > ODS > PPS > MP, while the analyte retention order paralleled thier pH2 values. On the other hand, an inverse relationship between the magnitude of capacity factors (k') and pK1 values of the title compounds was observed in experiments that produced retention data incompatible with ion-pair interaction rationales. The unique HPLC results obtained with the CDS phase are compared with those obtained with other phases.

  17. Sources of Variability in Chlorophyll Analysis by Fluorometry and by High Performance Liquid Chromatography. Chapter 22

    Science.gov (United States)

    VanHeukelem, Laurie; Thomas, Crystal S.; Glibert, Patricia M.

    2001-01-01

    The need for accurate determination of chlorophyll a (chl a) is of interest for numerous reasons. From the need for ground-truth data for remote sensing to pigment detection for laboratory experimentation, it is essential to know the accuracy of the analyses and the factors potentially contributing to variability and error. Numerous methods and instrument techniques are currently employed in the analyses of chl a. These methods range from spectrophotometric quantification, to fluorometric analysis and determination by high performance liquid chromatography. Even within the application of HPLC techniques, methods vary. Here we provide the results of a comparison among methods and provide some guidance for improving the accuracy of these analyses. These results are based on a round-robin conducted among numerous investigators, including several in the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) and HyCODE Programs. Our purpose here is not to present the full results of the laboratory intercalibration; those results will be presented elsewhere. Rather, here we highlight some of the major factors that may contribute to the variability observed. Specifically, we aim to assess the comparability of chl a analyses performed by fluorometry and HPLC, and we identify several factors in the analyses which may contribute disproportionately to this variability.

  18. High-performance liquid chromatography of quinoidal imminium compounds derived from triphenylmethanes

    Science.gov (United States)

    Abidi, S.L.

    1983-01-01

    A series of eleven p-aminotriphenylmethane dyes have been studied by high-performance liquid chromatography (HPLC). The combined use of HPLC and spectrophotometry permits specific detection of these compounds in the visible range around 600 nm. As the high affinity of the imminium cations for the active sites of the hydrocarbonaceous stationary phase has presented difficulties for reversed-phase HPLC with pure solvents, organic electrolytes were added to the mobile phase to facilitate the elution of the components with improved selectivity, sensitivity (minimum detection limit, 0.1 μg/ml), and peak symmetry. The effects of chromatographic variables on the component retentivity were investigated. Retention times of the dye analytes decreased with increasing concentration of the added ionic reagent and with decreasing number of the hydrophobic alkyl substituents on the nitrogen atom. The influence of pH on the retention parameters appears to parallel that observed previously for cationic quaternary ammonium compounds. Among the acidic reagents employed, naphthalenesulfonic acid yielded the most satisfactory results. The use of binary electrolyte systems invariably improved the chromatographic behavior of the imminium solutes analyzed. Results obtained with two different octadecylsilica columns have been compared.

  19. Chiral-phase high-performance liquid chromatography of rotenoid racemates

    Science.gov (United States)

    Abidi, S.L.

    1987-01-01

    The high-performance liquid chromatograhic (HPLC) behavior of parent rotenoids (type I) and the hydroxyl-analogues (type II) on three different chiral stationary phases (CSPs) was studied. Separations of optical isomers were achieved in various degrees depending largely upon the rotenoidal structures and the CSP types employed. Enantiomers of all but elliptone compounds were separable on β-cyclodextrin-bonded silica (CDS). Without exception, the 12a-hydroxyrotenoid antipodes were resolved on Pirkle's phenylglycine-bonded silica (PGS) despite unsuccessful attenmpts to resolve the type I rotenoidal racemates. Conversely, optical resolution of the latter rotenoids was accomplished by using a helical polytriphenylmethylacrylate-coated silica (TPS) column and the observed separation factors (α values) ranged from 1.14 to 1.90. The results from HPLC of type II rotenoids on TPS (α = 1.00–1.63) suggested that variations in E-ring structures had profound influence on the resolution outcome. Conjugated double bonds on the E-ring and the desisopropylation of the five-membered E-ring ot type II rotenoids appeared to be important structural features for chiral recognition involving the TPS substrate. In both reversed-phase (CDS) and normal-pahse (PGS and TPS) HPLC modes, the less polar enantiomers were the 6aβ,12aβ-rotenoids as observed in most cases, though this relationship was reversed in the cases of deguelin and hydroxyelliptone probably due to conformational effects of rotenoidal ring systems.

  20. Detection of HEMA in self-etching adhesive systems with high performance liquid chromatography

    Science.gov (United States)

    Panduric, V.; Tarle, Z.; Hameršak, Z.; Stipetić, I.; Matosevic, D.; Negovetić-Mandić, V.; Prskalo, K.

    2009-04-01

    One of the factors that can decrease hydrolytic stability of self-etching adhesive systems (SEAS) is 2-hydroxymethylmethacrylate (HEMA). Due to hydrolytic instability of acidic methacrylate monomers in SEAS, HEMA can be present even if the manufacturer did not include it in original composition. The aim of the study was to determine the presence of HEMA because of decomposition by hydrolysis of methacrylates during storage, resulting with loss of adhesion strength to hard dental tissues of the tooth crown. Three most commonly used SEAS were tested: AdheSE ONE, G-Bond and iBond under different storage conditions. High performance liquid chromatography analysis was performed on a Nucleosil C 18-100 5 μm (250 × 4.6 mm) column, Knauer K-501 pumps and Wellchrom DAD K-2700 detector at 215 nm. Data were collected and processed by EuroCrom 2000 HPLC software. Calibration curves were made related eluted peak area to known concentrations of HEMA (purchased from Fluka). The elution time for HEMA is 12.25 min at flow rate 1.0 ml/min. Obtained results indicate that no HEMA was present in AdheSE ONE because methacrylates are substituted with methacrylamides that seem to be more stable under acidic aqueous conditions. In all other adhesive systems HEMA was detected.

  1. Determination of Decabrominated Diphenyl Ether in Soils by Soxhlet Extraction and High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Xing-Jian Yang

    2013-01-01

    Full Text Available This study described the development of a method based on soxhlet extraction combining high performance liquid chromatography (soxhlet-HPLC for the accurate detection of BDE-209 in soils. The solvent effect of working standard solutions in HPLC was discussed. Results showed that 1 : 1 of methanol and acetone was the optimal condition which could totally dissolve the BDE-209 in environmental samples and avoid the decrease of the peak area and the peak deformation difference of BDE-209 in HPLC. The preliminary experiment was conducted on the configured grassland (1 μg/g to validate the method feasibility. The method produced reliable reproducibility, simulated soils (n=4 RSD 1.0%, and was further verified by the analysis e-waste contaminated soils, RSD range 5.9–11.4%. The contamination level of BDE-209 in burning site was consistent with the previous study of Longtang town but lower than Guiyu town, and higher concentration of BDE-209 in paddy field mainly resulted from the long-standing disassembling area nearby. This accurate and fast method was successfully developed to extract and analyze BDE-209 in soil samples, showing its potential use for replacing GC to determinate BDE-209 in soil samples.

  2. Quantitative structure-retention relationships of pesticides in reversed-phase high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Aschi, Massimiliano [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy); D' Archivio, Angelo Antonio [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy)]. E-mail: darchivi@univaq.it; Maggi, Maria Anna [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy); Mazzeo, Pietro [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy); Ruggieri, Fabrizio [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy)

    2007-01-23

    In this paper, a quantitative structure-retention relationships (QSRR) method is employed to predict the retention behaviour of pesticides in reversed-phase high-performance liquid chromatography (HPLC). A six-parameter nonlinear model is developed by means of a feed-forward artificial neural network (ANN) with back-propagation learning rule. Accurate description of the retention factors of 26 compounds including commonly used insecticides, herbicides and fungicides and some metabolites is successfully achieved. In addition to the acetonitrile content, included to describe composition of the water-acetonitrile mobile phase, the octanol-water partition coefficient (from literature) and four quantum chemical descriptors are considered to account for the effect of solute structure on the retention. These are: the total dipole moment, the mean polarizability, the anisotropy of polarizability and a descriptor of hydrogen bonding ability based on the atomic charges on hydrogen bond donor and acceptor chemical functionalities. The proposed nonlinear QSRR model exhibits a high degree of correlation between observed and computed retention factors and a good predictive performance in wide range of mobile phase composition (40-65%, v/v acetonitrile) that supports its application for the prediction of the chromatographic behaviour of unknown pesticides. A multilinear regression model based on the same six descriptors shows a significantly worse predictive capability.

  3. Description and validation of coupling high performance liquid chromatography with resonance Rayleigh scattering in aminoglycosides determination

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Lei [Chemistry and Chemical Engineering, Southwest University, 400715 Chongqing (China); Peng Jingdong, E-mail: hxpengjd@swu.edu.cn [Chemistry and Chemical Engineering, Southwest University, 400715 Chongqing (China); Tang Jinxia; Yuan Binfang; He Rongxing; Xiao Ying [Chemistry and Chemical Engineering, Southwest University, 400715 Chongqing (China)

    2011-11-14

    Graphical abstract: Theoretical and experimental analysis had proved that aminoglycosides reacted with Congo red to form binary compounds simultaneously, which led to a novel HPLC-RRS strategy being applied in substances which are not fluorescing and not UV absorbed. Highlights: {yields} A novel HPLC-RRS strategy was shown in this study. {yields} Theoretical and experimental analysis had proved the feasibility of this method. {yields} Because of its specificity, no interference from the matrix was observed. {yields} The analytes in biological matrix were all well resolved without any interference. {yields} It provided new insights for analytes lack of useful spectroscopic and electrochemical properties. - Abstract: In view of the fact that many substances generally exhibit very little ultraviolet absorbance and the absence of native fluorescence, a new strategy with simple instrumentation and excellent analytical performance combining high performance liquid chromatography (HPLC) with resonance Rayleigh scattering (RRS) was developed. It was validated for the quantification of aminoglycosides (AGs). This fact was also carefully calculated by quantum chemistry. However, the sensitivity was probably limited by the volume of flow-through cell. Therefore, the result calls for a suitable one to ensure optimal RRS signal. Interestingly, when serum or urine samples of analytes were analyzed by this method, they were all well resolved without any interference, which would hold a new perspective to be applied in the determination of substances in biological matrix.

  4. The MAREDAT global database of high performance liquid chromatography marine pigment measurements

    Science.gov (United States)

    Peloquin, J.; Swan, C.; Gruber, N.; Vogt, M.; Claustre, H.; Ras, J.; Uitz, J.; Barlow, R.; Behrenfeld, M.; Bidigare, R.; Dierssen, H.; Ditullio, G.; Fernandez, E.; Gallienne, C.; Gibb, S.; Goericke, R.; Harding, L.; Head, E.; Holligan, P.; Hooker, S.; Karl, D.; Landry, M.; Letelier, R.; Llewellyn, C. A.; Lomas, M.; Lucas, M.; Mannino, A.; Marty, J.-C.; Mitchell, B. G.; Muller-Karger, F.; Nelson, N.; O'Brien, C.; Prezelin, B.; Repeta, D.; Smith, W. O., Jr.; Smythe-Wright, D.; Stumpf, R.; Subramaniam, A.; Suzuki, K.; Trees, C.; Vernet, M.; Wasmund, N.; Wright, S.

    2013-03-01

    A global pigment database consisting of 35 634 pigment suites measured by high performance liquid chromatography was assembled in support of the MARine Ecosytem DATa (MAREDAT) initiative. These data originate from 136 field surveys within the global ocean, were solicited from investigators and databases, compiled, and then quality controlled. Nearly one quarter of the data originates from the Laboratoire d'Océanographie de Villefranche (LOV), with an additional 17% and 19% stemming from the US JGOFS and LTER programs, respectively. The MAREDAT pigment database provides high quality measurements of the major taxonomic pigments including chlorophylls a and b, 19'-butanoyloxyfucoxanthin, 19'-hexanoyloxyfucoxanthin, alloxanthin, divinyl chlorophyll a, fucoxanthin, lutein, peridinin, prasinoxanthin, violaxanthin and zeaxanthin, which may be used in varying combinations to estimate phytoplankton community composition. Quality control measures consisted of flagging samples that had a total chlorophyll a concentration of zero, had fewer than four reported accessory pigments, or exceeded two standard deviations of the log-linear regression of total chlorophyll a with total accessory pigment concentrations. We anticipate the MAREDAT pigment database to be of use in the marine ecology, remote sensing and ecological modeling communities, where it will support model validation and advance our global perspective on marine biodiversity. The original dataset together with quality control flags as well as the gridded MAREDAT pigment data may be downloaded from PANGAEA: http://doi.pangaea.de/10.1594/PANGAEA.793246.

  5. Determination of Capsaicin and Dihydrocapsaicin in Capsicum Fruit Samples using High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Ayman Abdel Ghafar

    2011-10-01

    Full Text Available The aim of the present study was to determine the content of capsaicin and dihydrocapsaicin in Capsicum samples collected from city markets in Riyadh (Saudi Arabia, calculate their pungency in Scoville heat units (SHU and evaluate the average daily intake of capsaicin for the population of Riyadh. The investigated samples consisted of hot chillies, red chillies, green chillies, green peppers, red peppers and yellow peppers. Extraction of capsaicinoids was done using ethanol as solvent, while high performance liquid chromatography (HPLC was used for separation, identification and quantitation of the components. The limit of detection (LOD of the method was 0.09 and 0.10 µg/g for capsaicin and dihydrocapsaicin, respectively, while the limit of quantification (LOQ was 0.30 and 0.36 µg/g for capsaicin and dihydrocapsaicin, respectively. Hot chillies showed the highest concentration of capsaicin (4249.0 ± 190.3 µg/g and the highest pungency level (67984.60 SHU, whereas green peppers had the lowest detected concentration (1.0 ± 0.9 µg/g; green peppers, red peppers and yellow peppers were non pungent. The mean consumption of peppers for Riyadh city population was determined to be 15.5 g/person/day while the daily capsaicin intake was 7.584 mg/person/day.

  6. Quality Evaluation of Potentilla fruticosa L. by High Performance Liquid Chromatography Fingerprinting Associated with Chemometric Methods

    Science.gov (United States)

    Liu, Wei; Wang, Dongmei; Liu, Jianjun; Li, Dengwu; Yin, Dongxue

    2016-01-01

    The present study was performed to assess the quality of Potentilla fruticosa L. sampled from distinct regions of China using high performance liquid chromatography (HPLC) fingerprinting coupled with a suite of chemometric methods. For this quantitative analysis, the main active phytochemical compositions and the antioxidant activity in P. fruticosa were also investigated. Considering the high percentages and antioxidant activities of phytochemicals, P. fruticosa samples from Kangding, Sichuan were selected as the most valuable raw materials. Similarity analysis (SA) of HPLC fingerprints, hierarchical cluster analysis (HCA), principle component analysis (PCA), and discriminant analysis (DA) were further employed to provide accurate classification and quality estimates of P. fruticosa. Two principal components (PCs) were collected by PCA. PC1 separated samples from Kangding, Sichuan, capturing 57.64% of the variance, whereas PC2 contributed to further separation, capturing 18.97% of the variance. Two kinds of discriminant functions with a 100% discrimination ratio were constructed. The results strongly supported the conclusion that the eight samples from different regions were clustered into three major groups, corresponding with their morphological classification, for which HPLC analysis confirmed the considerable variation in phytochemical compositions and that P. fruticosa samples from Kangding, Sichuan were of high quality. The results of SA, HCA, PCA, and DA were in agreement and performed well for the quality assessment of P. fruticosa. Consequently, HPLC fingerprinting coupled with chemometric techniques provides a highly flexible and reliable method for the quality evaluation of traditional Chinese medicines. PMID:26890416

  7. AB063. Prevalence of thalassemias and hemoglobinopathies detected via high performance liquid chromatography in Filipinos

    Science.gov (United States)

    Silao, Catherine Lynn; Fabella, Terence Diane; Yuson, Ernesto; Naranjo, Maria Liza; Padilla, Carmencita

    2015-01-01

    Background The thalassemias and hemoglobinopathies are groups of autosomal recessive inherited blood disorders affecting the quantity and quality of hemoglobin. Patients with the disease can vary from clinically asymptomatic to transfusion dependent individuals. It is considered prevalent in many parts of the world particularly in Southeast Asia. Thus, screening and prevalence determination of these diseases are important in the Filipino population. The study aims to determine the prevalence of thalassemias and hemoglobinopathies in the Philippines using high performance liquid chromatography. Methods Referred patients by hematologists from different parts of the country from October 2008 to December 2014 were included. Peripheral blood extracted from the subjects, were hemolyzed and screened for thalassemias and hemoglobinopathies using VariantTM HPLC. Data interpretations were based on levels of the HbA2 Fetal Hb and HbA detected. Results Majority of the patients were beta thalassemics followed by alpha-thalassemics. Hemoglobin E was found in 1% of the population tested while 2% of the patients have beta thalassemia with HbE interaction. Conclusions A significant proportion of thalassemias and hemoglobinopathies were determined from the 6-year screening of Filipinos using VariantTM HPLC. The results of this study provide not only confirmation of the occurrence and prevalence of these growing and diverse groups of genetic blood diseases but also suggest that the use of HPLC is a useful screening tool.

  8. Quantitative Determination of Compounds from Akebia quinata by High-Performance Liquid Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Yen, Nguyen; Thu, Nguyen; Zhao, Bing Tian; Woo, Mi Hee; Min, Byung Sun [Catholic Univ. of Daegu, Gyeongsan (Korea, Republic of); Lee, Jae Hyun [Dongguk Univ., Yongin (Korea, Republic of); Kim, Jeong Ah [Kyungpook National Univ., Daegu (Korea, Republic of); Son, Jong Keun [Yeungnam Univ., Gyeongsan (Korea, Republic of); Choi, Jae Sui [Pukyung National Univ., Busan (Korea, Republic of); Woo, Eun Rhan [Chosun Univ., Gwangju (Korea, Republic of)

    2014-07-15

    To provide the scientific corroboration of the traditional uses of Akebia quinata (Thunb.) Decne., a detailed analytical examination of A. quinata stems was carried out using a reversed-phase high performance liquid chromatography (RP-HPLC) method coupled to photodiode array detector (PDA) for the simultaneous determination of four phenolic substances; cuneataside D, 2-(3,4-dihydroxyphenyl)ethyl-O-β-D-glucopyranoside, 3-caffeoylquinic acid and calceolarioside B. Particular attention was focused on the main compound, 3-caffeoylquinic acid, which has a range of biological functions. In addition, 2-(3,4-dihydroxyphenyl)ethyl-O-β-D-glucopyranoside was considered as a discernible marker of A. quinata from its easy confuse plants. The contents of compounds 2 and 3 ranged from 0.72 to 2.68 mg/g and from 1.66 to 5.64 mg/g, respectively. The validation data indicated that this HPLC/PDA assay was used successfully to quantify the four phenolic compounds in A. quinata from different locations using relatively simple conditions and procedures. The pattern-recognition analysis data from 53 samples classified them into two groups, allowing discrimination between A. quinata and comparable herbs. The results suggest that the established HPLC/PDA method is suitable for quantitation and pattern-recognition analyses for a quality evaluation of this medicinal herb.

  9. Determination of sulphachloropyrazine-diaveridine residues by high performance liquid chromatography in broiler edible tissues

    Science.gov (United States)

    LI, Yongjun; BU, Shijin

    2015-01-01

    Diaveridine (DVD) is used in combination with sulphachloropyrazine (SPZ) as an effective antibacterial agent and antiprotozoal agent, respectively, in humans and animals. To gain a better understanding of the metabolism of SPZ and DVD in the food-producing animals, a high performance liquid chromatography (HPLC) method to determine and quantify sulphachloropyrazine (SPZ) and diaveridine (DVD) suspension residues from broilers is reported. Thirty healthy chickens were orally administered with sulphachloropyrazine-diaveridine (SPZ-DVD) suspension in water of 300 mg/l (SPZ) per day for seven successive days. Six chickens per day were slaughtered at 0, 1, 3, 5 and 7 days after the last administration. This procedure permitted SPZ and DVD to be separated from muscle tissue, liver, kidneys and skin with fat after extraction with acetonitrile and acetone under slightly acidic conditions. From the detected residuals in different tissues, we found that SPZ was quickly eliminated in liver and muscle, and slowly eliminated in kidney and skin with fat. DVD was quickly eliminated in liver and slowly eliminated in kidney. The withdrawal period of SPZ was 3.26, 3.72, 4.39 and 5.43 days in muscle, liver, kidney and skin with fat, respectively. The withdrawal period of DVD was 4.77, 4.94, 6.74 and 4.58 days in muscle, liver, kidney and skin with fat, respectively. Therefore, the suggested withdrawal period for SPZ-DVD suspension should be 7 days after dosing for seven successive days. PMID:26212255

  10. Analysis of Fluconazole in Human Urine Sample by High Performance Liquid Chromatography Method

    Science.gov (United States)

    Hermawan, D.; Ali, N. A. Md; Ibrahim, W. A. Wan; Sanagi, M. M.

    2013-04-01

    A method for determination of fluconazole, antifungal drug in human urine by using reversed-phased high performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detector was developed. Optimization HPLC conditions were carried out by changing the flow rate and composition of mobile phase. The optimum separation conditions at a flow rate 0.85 mL/min with a composition of mobile phase containing methanol:water (70:30, v/v) with UV detection at a wavelength 254 nm was able to analyze fluconazole within 3 min. The excellent linearity was obtained in the range of concentration 1 to 10 μg/mL with r2 = 0.998. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.39 μg/mL and 1.28 μg/mL, respectively. Solid phase extraction (SPE) method using octadecylsilane (C18) as a sorbent was used to clean-up and pre-concentrated of the urine sample prior to HPLC analysis. The average recoveries of fluconazole in spiked urine sample was 72.4% with RSD of 3.21% (n=3).

  11. High-performance liquid chromatography method validation for determination of tetracycline residues in poultry meat

    Directory of Open Access Journals (Sweden)

    Vikas Gupta

    2014-01-01

    Full Text Available Background: In this study, a method for determination of tetracycline (TC residues in poultry with the help of high-performance liquid chromatography technique was validated. Materials and Methods: The principle step involved in ultrasonic-assisted extraction of TCs from poultry samples by 2 ml of 20% trichloroacetic acid and phosphate buffer (pH 4, which gave a clearer supernatant and high recovery, followed by centrifugation and purification by using 0.22 μm filter paper. Results: Validity study of the method revealed that all obtained calibration curves showed good linearity (r2 > 0.999 over the range of 40-4500 ng. Sensitivity was found to be 1.54 and 1.80 ng for oxytetracycline (OTC and TC. Accuracy was in the range of 87.94-96.20% and 72.40-79.84% for meat. Precision was lower than 10% in all cases indicating that the method can be used as a validated method. Limit of detection was found to be 4.8 and 5.10 ng for OTC and TC, respectively. The corresponding values of limit of quantitation were 11 and 12 ng. Conclusion: The method reliably identifies and quantifies the selected TC and OTC in the reconstituted poultry meat in the low and sub-nanogram range and can be applied in any laboratory.

  12. [Determination of five coumarins in toys by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Yang, Rongjing; Wei, Biwen; Gao, Huan; Yu, Wenjia

    2012-02-01

    A rapid analytical method for the determination of five coumarins (coumarin, 7-methoxycoumarin, dihydrocoumarin, 7-methyl coumarin and 7-ethoxy-4-methyl coumarin) in toys by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has been developed. After ultrasonic extraction in tetrahydrofuran, the samples were analyzed by HPLC-MS/MS in multi-reaction monitoring (MRM) mode. Acetonitrile and 0.1% acetic acid were used as the mobile phases with gradient elution. The linear ranges of calibration curves were 10 - 1 000 microg/L, and the limits of quantification (LOQ) (S/N > 10) were 2.0 microg/L for all the analytes, except that the LOQ for dihydrocoumarin was 5.0 microg/L. The recoveries of the five coumarins spiked in three types of samples were in the ranges of 93.2% - 105.8%, 97.3% - 103.2% and 96.8% - 102.9%, with the relative standard deviations in the ranges of 4.35% - 8.27%, 3.65% - 6.73% and 4.03% - 6.45%, respectively. The method was applied in the determination of 12 toy samples. The five analytes were found in 9 samples, and in some cases, the presence of quite high concentrations of these coumarins in the toys should be a matter of concern.

  13. Analysis of lipoprotein profiles of healthy cats by gel-permeation high-performance liquid chromatography.

    Science.gov (United States)

    Mizutani, Hisashi; Sako, Toshinori; Okuda, Hiroko; Arai, Nobuaki; Kuriyama, Koji; Mori, Akihiro; Yoshimura, Itaru; Koyama, Hidekazu

    2016-09-01

    Density gradient ultracentrifugation (DGUC) and gel electrophoresis are conventionally used to obtain lipoprotein profiles of animals. We recently applied high-performance liquid chromatography with a gel permeation column (GP-HPLC) and an on-line dual enzymatic system to dogs for lipoprotein profile analysis. We compared the GP-HPLC with DGUC as a method to obtain a feline lipoprotein profile. The lipoprotein profiles showed large and small peaks, which corresponded to high-density lipoprotein (HDL) and low-density lipoprotein (LDL), respectively, whereas very low-density lipoprotein (VLDL) and chylomicron (CM) were only marginally detected. This profile was very similar to that of dogs reported previously. Healthy cats also had a small amount of cholesterol-rich particles distinct from the normal LDL or HDL profile. There was no difference in lipoprotein profiles between the sexes, but males had a significantly larger LDL particle size (P=0.015). This study shows the feasibility of GP-HPLC for obtaining accurate lipoprotein profiles with small sample volumes and provides valuable reference data for healthy cats that should facilitate diagnoses.

  14. Determination of xanthohumol in beer based on cloud point extraction coupled with high performance liquid chromatography.

    Science.gov (United States)

    Chen, Ligang; Zhao, Qi; Jin, Haiyan; Zhang, Xiaopan; Xu, Yang; Yu, Aimin; Zhang, Hanqi; Ding, Lan

    2010-04-15

    A method based on coupling of cloud point extraction (CPE) with high performance liquid chromatography separation and ultraviolet detection was developed for determination of xanthohumol in beer. The nonionic surfactant Triton X-114 was chosen as the extraction medium. The parameters affecting the CPE were evaluated and optimized. The highest extraction yield of xanthohumol was obtained with 2.5% of Triton X-114 (v/v) at pH 5.0, 15% of sodium chloride (w/v), 70 degrees C of equilibrium temperature and 10 min of equilibrium time. Under these conditions, the limit of detection of xanthohumol is 0.003 mg L(-1). The intra- and inter-day precisions expressed as relative standard deviations are 4.6% and 6.3%, respectively. The proposed method was successfully applied for determination of xanthohumol in various beer samples. The contents of xanthohumol in these samples are in the range of 0.052-0.628 mg L(-1), and the recoveries ranging from 90.7% to 101.9% were obtained. The developed method was demonstrated to be efficient, green, rapid and inexpensive for extraction and determination of xanthohumol in beer.

  15. Quantification of mRNA by RT-competitive-PCR and high performance liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The use of RT-competitive-PCR with high performance liquid chromatography (HPLC) detection to quantify the absolute number of mRNA copies in mammalian cells is reported. As an example, the glutathione transferase (GST)-α mRNA in human hepatoma Hep G2 cells has been estimated. A PCR-generated internal standard was used as a competitor, co-amplified with the GST-α target sequence. The RT-competitive-PCR method was improved by designing target and competitor molecules which differed in only 30 base pairs. This allowed the two sequences to be co-amplified with the same efficiency. This improvement also facilitated a wider ratio to be used than previous methods (target:competitor ratio between 0.2 and 5). Products were baseline separated by HPLC using an ion-exchange column readily quantified at 260 nm. To validate the improved methodology, the effect of a known GST-α inducer, the anticancer drug oltipraz, was shown to induce GST-α mRNA up to 3-fold in Hep G2 cells. The RT-competitive PCR-HPLC method provides a reliable and sensitive way to quantify the amount of specific mRNA with 0.1 ng of total RNA.

  16. DETERMINATION OF TELMISARTAN IN PHARMACEUTICAL FORMULATIONS BY REVERSE PHASE-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    Manoj S. Charde

    2012-05-01

    Full Text Available A simple, sensitive and reproducible reverse-phase high performance liquid chromatographic (RP-HPLC method has been developed for the quantitative estimation of Telmisartan (TELM in the pharmaceutical formulations. Chromatographic separation was achieved on a 250 × 4.6 mm, 5μ, Waters symmetry column. The flow rate was 1 ml/min and eluent was monitored by absorbance at 230 nm using a mixture of Methanol and Acetonitrile (pH 3.0±0.01 in the ratio of 30:70 (v/v. The retention time of Telmisartan was found to be 7.9 min. Calibration plots were linear in the concentration range of 10-50 μg/ml for Telmisartan with correlation coefficient (R2 0.999. The proposed method was validated by testing its linearity, recovery, specificity, system suitability, precision (Interday, intraday, analyst and instrument precision, robustness and LOD/LOQ values and it was successfully employed for the determination of Telmisartan in pharmaceutical tablet formulations.

  17. Sequence-dpenedent DNA separation by anion-exchange high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Yamakawa, Hisashi; Higashino, Ken-ich; Ohara, Osamu [Kazusa DNA Research Inst., Chiba (Japan)

    1996-09-05

    High-performance liquid chromatography (HPLC) system with a new nonporous anion-exchange resin, DNA-NPR, made it possible to rapidly separate DNA fragments up to 20 kbp with high resolution. In order to further characterize this chromatographic DNA separation system, we prepared a mixtures of double-stranded DNAs of constant length carrying a fully degenerated 50-bp region and analyzed their chromatographic behavior on the DNA-NPR column. The results indicated that the separation of DNA fragments on the anion-exchange HPLC was governed not only by size, but also by nucleotide sequence: even DNA fragments with the same size and the same base content could be separated on this column. Taking advantage of this characteristic feature of the anion-exchange HPLC, we could readily fractionate human cDNAs with practically acceptable recovery and high resolution. Furthermore, the combination of HPLC and gel electrophoresis realized separation of a mixture of DNA fragments in a two-dimensional pattern. 22 refs., 5 figs., 1 tab.

  18. Determination of Acrylamide Metabolite ,Mercapturic Aicd by High Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    WUYi-Qun; YUAi-Ru; 等

    1993-01-01

    A HPLC Assay was developed to indentify and measure the metabolite of acrylamide,mercapturic acid,N-Acetyl-s-(propionamide)-cyteine(APC)in urine O-phthalaldehyde (OPA)was utilized as a precolumm derivatizing agent in the assay.This derivative was isolated with a good selectivity by high performance liquid chromatography(HPLC)employing reversed phase ODS columns.The quantiation of the mercapturic acid derivative was reproducible and with a detection limit of 1 pmol.The average coefficient of variation for the runs carried out on the same day was approximately 4.6% at the range of 80-160μmol·l-1 of APC,and the mean analytical recovery from urine samples was 94%.The metabolite of urine of workers exposed to acrylamide was identified as N-acetyl-s-(propionamide)-cysteine by HPLC chromatography and fluorescence scan and HPLC-Mass spectra.All results were identical with the authentic synthesized compound.

  19. [Determination of histamine in canned fish by high performance liquid chromatography with pre-column derivatization].

    Science.gov (United States)

    Jin, Gaowa; Cai, Youqiong; Yu, Huijuan; Qian, Beilei

    2010-11-01

    A pre-column derivatization-high performance liquid chromatographic (HPLC) method has been developed for the determination of histamine in canned fish. The homogenated samples were ultrasonically extracted with perchloric acid aqueous solution, derivatized with dansyl chloride and diluted with acetonitrile to a desired volume. The samples were determined by HPLC with ultraviolet detector and quantified by external standard method. Adopting a C18 column with 1.8 microm stationary phase particles, the analysis time for each sample was smaller than 5 min with the flow rate of 0.3 mL/min. It can decrease the consumption of the mobile phase and save the cost. The linear range was 0.08-8.00 mg/L for histamine. The correlation coefficient was 0.999 98. The average recoveries of histamine at different concentration levels in spiked samples were greater than 96% and the relative standard deviations (RSDs) were smaller than 2.5%. The quantitation limit was 5.00 mg/kg for histamine in canned fish by HPLC. The results indicated that this HPLC method is fast, sensitive, reproducible and practical for the routine analysis of histamine in canned fish.

  20. A stability-indicating high performance liquid chromatography method to determine apocynin in nanoparticles

    Directory of Open Access Journals (Sweden)

    Juliana Kovalczuk de Oliveira

    2017-04-01

    Full Text Available In this study, we developed and validated a fast, specific, sensitive, precise and stability-indicating high performance liquid chromatography (HPLC method to determine the drug apocynin in bovine serum albumin (BSA nanoparticles. Chromatographic analyses were performed on an RP C18 column and using a photodiode array detector at a wavelength of 276 nm. Mobile phase consisted of a mixture of acetonitrile and 1% acetic acid (60:40, v/v, and it was eluted isocratically at a flow rate of 0.8 mL/min. The retention time of apocynin chromatographic peak was 1.65 min. The method was linear, precise, accurate and specific in the range of 5–100 μg/mL. The intra- and inter-day precisions presented relative standard deviation (RSD values lower than 2%. The method was robust regarding changes in mobile phase proportion, but not for flow rate. Limits of detection and quantitation were 78 ng/mL and 238 ng/mL, respectively. Apocynin was exposed to acid and alkali hydrolysis, oxidation and visible light. The drug suffered mild degradation under acid and oxidation conditions and great degradation under alkali conditions. Light exposure did not degrade the drug. The method was successfully applied to determine the encapsulation efficiency of apocynin in BSA nanoparticles.

  1. Simultaneous Determination of Four Preservatives in Foodstuffs by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Mohammad Faraji

    2016-04-01

    Full Text Available Background and objectives:  High concentration of preservatives in food may result in gastrointestinal disturbances whereby some patients suffering from asthma, rhinitis, or urticaria. The aim of this study is the introduction and optimization a new method for simultaneous determination of four preservatives (SB, PS, MP, PP in foodstuff by high performance liquid chromatography. Materials and methods: Important factors in extraction, separation and determination process were optimized using the one variable at a time method.  Figures of merit of the proposed method were evaluated. The amount of SB, PS, MP, PP in some food samples were determined using the proposed method. Result: The results showed that the obtained chromatogram of extract was free of significant interferences. The preservatives recoveries ranged from 88% to 110 %. Concentration of SB, PS, MP and PP in the 20studied samples ranges between N.D-639.9, N.D -214.5, N.D -579.8 and N.D -30.5 mg kg-1, respectively  Conclusion: The performance and reliability of proposed method as a simple, efficient and fast method for determination of SB, PS, MP, PP in the food samples was demonstrated.

  2. High-performance liquid chromatographic separation of subcomponents of antimycin A.

    Science.gov (United States)

    Abidi, S L

    1988-08-05

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, A1a, A1b, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins A1, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpreted based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  3. High-performance liquid-chromatographic separation of subcomponents of antimycin-A

    Science.gov (United States)

    Abidi, S.L.

    1988-01-01

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  4. High-Performance Liquid Chromatographic Quantification of Flavonoids in Eriocaulaceae Species and Their Antimicrobial Activity

    Directory of Open Access Journals (Sweden)

    Lourdes Campaner dos Santos

    2009-11-01

    Full Text Available Quantification of prepared samples by analysis using high performance liquid chromatography with DAD detection was developed to analyze rutin, 6-methoxyapigenin, and 6-methoxyapigenin-7-O-β-D-glucopyranoside isolated from methanolic extracts of different genus: Syngonanthus, Leiothix and Eriocaulon (Eriocaulaceae. The linearity, accuracy, and the inter-day precision of the procedure were evaluated. The calibration curves were linear. The recoveries of the flavonoids in the samples analyzed were 96.3% to 98.5%. The percentage coefficient of variation for the quantitative analysis of the flavonoids in the analyses of the samples was under 5%. The antimicrobial activity of the five methanol extracts of these Eriocaulaceae species was assayed against the microorganisms Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Salmonella setubal, Saccharomyces cerevisiae and Candida albicans. Measured MIC values ranged from 1.25 to 10.00 mg/mL. The flavonoid contents suggest that Eriocaulaceae species may be a promising source of compounds to produce natural phytomedicines.

  5. Simultaneous determination of quinolones for veterinary use by high-performance liquid chromatography with electrochemical detection.

    Science.gov (United States)

    Rodríguez Cáceres, M I; Guiberteau Cabanillas, A; Galeano Díaz, T; Martínez Cañas, M A

    2010-02-01

    A selective method based on high-performance liquid chromatography with electrochemical detection (HPLC-ECD) has been developed to enable simultaneous determination of three fluoroquinolones (FQs), namely danofloxacin (DANO), difloxacin (DIFLO) and sarafloxacin (SARA). The fluoroquinolones are separated on a Novapack C-18 column and detected in a high sensitivity amperometric cell at a potential of +0.8 V. Solid-phase extraction was used for the extraction of the analytes in real samples. The range of concentration examined varied from 10 to 150 ng g(-1) for danofloxacin, from 25 to 100 ng g(-1) for sarafloxacin and from 50 to 315 ng g(-1) for difloxacin, respectively. The method presents detection limits under 10 ng g(-1) and recoveries around 90% for the three analytes have been obtained in the experiments with fortified samples. This HPLC-ECD approach can be useful in the routine analysis of antibacterial residues being less expensive and less complicated than other more powerful tools as hyphenated techniques.

  6. High-Performance Liquid Chromatographic Resolution of Neutral and Cationic Hetero[6]Helicenes.

    Science.gov (United States)

    Labrador, Geraldine M; Bosson, Johann; Breitbach, Zachary S; Lim, Yeeun; Francotte, Eric R; Sabia, Rocchina; Villani, Claudio; Armstrong, Daniel W; Lacour, Jérôme

    2016-04-01

    Cationic hetero[6]helicenes 1+, 2+ and 3+ have been recently disclosed. Herein we report on their enantiomeric separation using high-performance liquid chromatography. Separation of the antipodes can be achieved in preparative scale on neutral adducts with Chiralcel OD-I or Chiralpak ID CSP. Selectivity factors of 1.90, 1.67, and 1.96 were obtained for 1-H, 2-H, and 3-H, respectively. Separation can also be performed on the carbenium ions on regular Chiralpak IA CSP using water-containing eluents, thus allowing for enantiomeric purity determinations in aqueous environments. Resolution of neutral and cationic helicenes is also achieved on more recently developed LARIHC columns. The versatility of the cyclofructan phases allows for baseline separations for both cases and their loading capabilities are demonstrated. Finally, the configurational stability of 1+, 2+, and 3+ was measured. For each replacement of an oxygen atom by an amino group, the racemization barrier increases significantly (ΔG‡ = 29.8, 36.3 and >37 kcal mol(-1) for 1+, 2+, and 3+ respectively).

  7. Simultaneous determination of caffeine, theobromine, and theophylline by high-performance liquid chromatography.

    Science.gov (United States)

    Bispo, Marcia S; Veloso, Márcia Cristina C; Pinheiro, Heloísa Lúcia C; De Oliveira, Rodolfo F S; Reis, José Oscar N; De Andrade, Jailson B

    2002-01-01

    This work relates the development of an analytical methodology to simultaneously determine three methylxanthines (caffeine, theobromine, and theophylline) in beverages and urine samples based on reversed-phase high-performance liquid chromatography. Separation is made with a Bondesil C18 column using methanol-water-acetic acid or ethanol-water-acetic acid (20:75:5, v/v/v) as the mobile phase at 0.7 mL/min. Identification is made by absorbance detection at 273 nm. Under optimized conditions, the detection limit of the HPLC method is 0.1 pg/mL for all three methylxanthines. This method is applied to urine and to 25 different beverage samples, which included coffee, tea, chocolate, and coconut water. The concentration ranges determined in the beverages and urine are: theobromine; < 0.1 pg/mL to 47 microg/mL and < 0.1 pg/mL to 66.3 microg/mL for theophylline. The method proposed in this study is rapid and suitable for the simultaneous quantitation of methylxanthines in beverages and human urine samples and requires no extraction step or derivatization.

  8. Molecular monitoring of the intestinal flora by denaturing high performance liquid chromatography.

    Science.gov (United States)

    Goldenberg, Oliver; Herrmann, Stefanie; Marjoram, Gina; Noyer-Weidner, Mario; Hong, George; Bereswill, Stefan; Göbel, Ulf B

    2007-01-01

    Gut flora analysis is hampered by the complexity of the intestinal microbiota and by inherent limitations of culture-based approaches. Therefore, culture-independent molecular methods based upon 16S rRNA gene analysis were applied successfully for the analysis of complex microbial communities. However, generally accepted and validated profiling methods such as denaturing and temperature gradient gel electrophoresis (DGGE/TGGE) are still laborious and time consuming. Thus, we adapted the separation of amplified bacterial 16S rRNA gene fragments by denaturing high performance liquid chromatography (DHPLC) using the WAVE Microbial Analysis System as a rapid and convenient means to display complex intestinal bacterial communities and to monitor changes in the gut flora. The separation of 16S rRNA gene fragments amplified from reference strains representing main gut bacterial populations and from human stool samples revealed that DHPLC analysis effectively detects bacterial groups predominant in the human gut flora. The investigation of faecal samples from hospitalized patients before, during and after antibiotic therapy showed that PCR-based DHPLC can be used to monitor gut flora changes. Results from DHPLC analysis were comparable with DGGE profiles generated from the same samples, demonstrating that the adapted DHPLC protocol is well suited for the analysis of complex microbial communities.

  9. Determination of Duloxetine and Its Major Metabolites in Rabbit Plasma by High-Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    T. K. Laha

    2015-03-01

    Full Text Available A rapid and sensitive high performance liquid chromatographic method is described for simultaneous determination of duloxetine and its major metabolites, such as 4- hydroxy duloxetine (M7, Glucuronide conjugate of 5-hydroxy-6-methoxy duloxetine (M6 and Glucuronide conjugate of dihydrodiol duloxetine (M12 in rabbit plasma. HPLC analysis was carried out on a µ-Bondapak C18 column (250 mm × 4.6 mm, 5µm particle size using methanol: phosphate buffer (pH 7.9, 50 mM (7:3 v/v as the mobile phase at a flow rate of 1.5 ml/min. Detection was carried out at 224 nm with an UV detector. The above metabolites present in the rabbit plasma were characterized by retro-synthesis followed by NMR and MS study for structure confirmation and finally injected separately into the HPLC system. All the three retention time matches with the metabolites present in the plasma sample.

  10. Development and Validation of Reversed-Phase High Performance Liquid Chromatographic Method for Hydroxychloroquine Sulphate.

    Science.gov (United States)

    Singh, A; Roopkishora; Singh, C L; Gupta, R; Kumar, S; Kumar, M

    2015-01-01

    In the present work new, simple reversed-phase high performance liquid chromatographic method was developed and validated for the determination of hydroxychloroquine sulphate in blood plasma. Chloroquine sulphate was used as an internal standard. The chromatographic separation was achieved with octadecyl silane Hypersil C18 column (250×6 mm, 5 μm) using water and organic (acetonitrile:methanol: 50:50, v/v) mobile phase in 75:25 v/v ratio, with sodium 1-pentanesulfonate and phosphoric acid. This organic phase was maintained at pH 3.0 by orthophosphoric acid. The flow rate of 2.0 ml/min(.) with detection at 343 nm was used in the analysis. The calibration curve of standard hydroxychloroquine sulphate was linear in range 0.1-20.0 μg/ml. The method was validated with respected to linearity, range, precision, accuracy, specificity and robustness studies according to ICH guidelines. The method was found to be accurate and robust to analyze the hydroxychloroquine sulphate in plasma samples.

  11. Development and validation of a high-performance liquid chromatographic method for bioanalytical application with rimonabant.

    Science.gov (United States)

    Bhaumik, Uttam; Ghosh, Animesh; Chatterjee, Bappaditya; Sengupta, Pinaki; Darbar, Soumendra; Roy, Bikash; Nandi, Utpal; Pal, Tapan K

    2009-05-01

    A simple and feasible high-performance liquid chromatographic method with UV detection was developed and validated for the quantification of rimonabant in human plasma. The chromatographic separation was carried out in a Hypersil BDS, C(18) column (250 mm x 4.6mm; 5 microm). The mobile phase was a mixture of 10 mM phosphate buffer and acetonitrile (30:70, v/v) at a flow rate of 1.0 ml/min. The UV detection was set at 220 nm. The extraction recovery of rimonabant in plasma at three quality control (QC) samples was ranged from 84.17% to 92.64%. The calibration curve was linear for the concentration range of 20-400 ng/ml with the correlation coefficient (r(2)) above 0.9921. The method was specific and sensitive with the limit of quantification of 20 ng/ml. The accuracy and precision values obtained from six different sets of QC samples analyzed in separate occasions ranged from 88.13% to 106.48% and 0.13% to 3.61%, respectively. In stability tests, rimonabant in human plasma was stable during storage and assay procedure. The method is very simple, sensitive and economical and the assay was applied to human plasma samples in a clinical (pharmacokinetic) study of rimonabant.

  12. Determination of purine contents in different parts of pork and beef by high performance liquid chromatography.

    Science.gov (United States)

    Rong, Shengzhong; Zou, Lina; Zhang, Yannan; Zhang, Guangteng; Li, Xiaoxia; Li, Miaojing; Yang, Fenghua; Li, Chunmei; He, Yingjuan; Guan, Hongjun; Guo, Yupeng; Wang, Dong; Cui, Xinyu; Ye, Hongting; Liu, Fenghai; Pan, Hongzhi; Yang, Yuexin

    2015-03-01

    Determination of adenine, hypoxanthine, guanine and xanthine in different parts of pork and beef using high performance liquid chromatography was described. Chromatographic separation was carried out on Waters Atlantis T3 column (4.6 mm × 250 mm × 5 μm) with column temperature at 30 °C. The mobile phase contained 99% 10.0 mmol/L ammonium formate solution at pH 3.6 and 1.0% methanol. Chromatography was achieved at a flow rate of 1.0 mL/min and detection wavelength at 254 nm. The results indicated that total purine amounts in pork rump and beef sirloin were higher than those in other parts (Ppurine bases were hypoxanthine and adenine, and hypoxanthine content was the most highest in all samples (Ppurine and uricogenic purine base, we suggest that excess consumption of them be avoid, whereas pork loin chop and beef rib eye are more suitable for a low-purine diet. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. A novel high-performance liquid chromatography fingerprint approach to discriminate Phyllostachys pubescens from China

    Directory of Open Access Journals (Sweden)

    Jin Yong-Chun

    2012-01-01

    Full Text Available Background: A high-performance liquid chromatography fingerprint of different variants of Phyllostachys pubescens was developed for the source discrimination and quality control of Phyllostachys pubescens medicines produced in Zhejiang Province, China. Materials and Methods: Samples of Phyllostachys pubescens collected from nine cultivars in Zhejiang Province were used to establish the fingerprint. Taking the chromatographic peak (isoorientin as the reference peak, the chromatographic column was Sunfire C 18 ODS (250 mm×4.6 mm, 5 ΅m at a column temperature of 25°C. The mobile phase was acetonitrile 0.8% acetic acid water solution (in a gradient elution mode at a flow rate of 1 ml/min. The detection wavelength was 330 nm. Results: 20 common peaks were established in the chromatographic fingerprints of Phyllostachys pubescens. And then by comparing the UV and standard substance with those of the authentic standards and literature, eight main peaks in the fingerprints were identified. Data of nine cultivars were evaluated statistically using similarity analysis, hierarchical cluster analysis (HCA in order to establish a similarity standard of fingerprint for quality control of Phyllostachys pubescens, then to classify the samples. The similarity indexes were all above 0.95 between reference chromatogram and each sample′s chromatogram. Conclusion: in this study, the methods established are reliable, and could be used to evaluate the quality and to identify the species of Phyllostachys pubescens in the future.

  14. Chemical fingerprint analysis of Gentianae Radix et Rhizoma by high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Baozhong Duan

    2012-02-01

    Full Text Available Gentianae Radix et Rhizoma (also called “Longdan” in Chinese is commonly used for eliminating damp-heat and quenching the fire of liver and gall bladder in traditional Chinese medicine. In this study, a novel and reliable method using high-performance liquid chromatography (HPLC was developed both for quantitative analysis of four bioactive compounds (loganic acid, swertiamarin, gentiopicroside and sweroside and chemical fingerprint analysis of “Longdan”. In quantitative analysis, four compounds showed good regressions (R2>0.9987 within the test ranges and the recovery of the method was in the range 97.61−102.49%. In fingerprint analysis, ten characteristic peaks were selected to evaluate the similarities of the crude drugs, and the HPLC chromatograms of twenty samples from different regions of China showed similar patterns. The results demonstrated that the combination of the quantitative and chromatographic fingerprint analyses offered an efficient way to evaluate the quality consistency of Gentianae Radix et Rhizoma.

  15. Fingerprint chromatogram analysis of Pseudostellaria heterophylla (Miq.) Pax root by high performance liquid chromatography.

    Science.gov (United States)

    Han, Chao; Chen, Junhui; Chen, Bo; Lee, Frank Sen-Chun; Wang, Xiaoru

    2006-09-01

    A simple and reliable high performance liquid chromatographic (HPLC) method has been developed and validated for the fingerprinting of extracts from the root of Pseudostellaria heterophylla (Miq.) Pax. HPLC with gradient elution was performed on an authentic reference standard of powdered P. heterophylla (Miq.) Pax root and 11 plant samples of the root were collected from different geographic locations. The HPLC chromatograms have been standardized through the selection and identification of reference peaks and the normalization of retention times and peak intensities of all the common peaks. The standardized HPLC fingerprints show high stability and reproducibility, and thus can be used effectively for the screening analysis or quality assessment of the root or its derived products. Similarity index calculations based on cosine angle values or correlation methods have been performed on the HPLC fingerprints. As a group, the fingerprints of the P. heterophylla (Miq.) Pax samples studied are highly correlated with closely similar fingerprints. Within the group, the samples can be further divided into subgroups based on hierarchical clustering analysis (HCA). Sample grouping based on HCA coincides nicely with those based on the geographical origins of the samples. The HPLC fingerprinting techniques thus have high potential in authentication or source-tracing types of applications.

  16. Determination of capsaicin and dihydrocapsaicin in Capsicum fruit samples using high performance liquid chromatography.

    Science.gov (United States)

    Al Othman, Zeid Abdullah; Ahmed, Yacine Badjah Hadj; Habila, Mohamed Abdelaty; Ghafar, Ayman Abdel

    2011-10-24

    The aim of the present study was to determine the content of capsaicin and dihydrocapsaicin in Capsicum samples collected from city markets in Riyadh (Saudi Arabia), calculate their pungency in Scoville heat units (SHU) and evaluate the average daily intake of capsaicin for the population of Riyadh. The investigated samples consisted of hot chillies, red chillies, green chillies, green peppers, red peppers and yellow peppers. Extraction of capsaicinoids was done using ethanol as solvent, while high performance liquid chromatography (HPLC) was used for separation, identification and quantitation of the components. The limit of detection (LOD) of the method was 0.09 and 0.10 µg/g for capsaicin and dihydrocapsaicin, respectively, while the limit of quantification (LOQ) was 0.30 and 0.36 µg/g for capsaicin and dihydrocapsaicin, respectively. Hot chillies showed the highest concentration of capsaicin (4249.0 ± 190.3 µg/g) and the highest pungency level (67984.60 SHU), whereas green peppers had the lowest detected concentration (1.0 ± 0.9 µg/g); green peppers, red peppers and yellow peppers were non pungent. The mean consumption of peppers for Riyadh city population was determined to be 15.5 g/person/day while the daily capsaicin intake was 7.584 mg/person/day.

  17. REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD FOR THE ANALYSIS OF GLIPIZIDE IN PHARMACEUTICAL DOSAGE FORMS

    Directory of Open Access Journals (Sweden)

    Sheikh Rahila

    2010-12-01

    Full Text Available A rapid and sensitive reverse phase high performance liquid chromatographic methods depicted for the qualitative and quantitative assay of glipizide in pharmaceutical dosage forms. Glipizide was chromatographed on reverse phase C18 column with mobile phase consisting of 0.05 M Potassium Dihydrogen Orthophosphate: Methanol [15: 85 %v/v, pH 7.0 ± 0.05, adjusted with 1% Triethylamine]. The mobile phase was pumped at a flow rate 1 mL/min. Quantification was achieved by monitoring the ultraviolet absorbance at 225 ηm. The average retention time for Glipizide was found to be 3.21 ± 0.07. With this method, linearity was observed in the range of 10 – 2000 ηg/ml. The LOD and LOQ were found to be 5 ηg/ml and 15 ηg/ml respectively. The method was applicable for the analysis of drug in tablet formulation. The results of analysis were validated statistically.

  18. Analysis of metalaxyl racemate using high performance liquid chromatography coupled with four kinds of detectors.

    Science.gov (United States)

    Chen, Tao; Fan, Jun; Gao, Ruiqi; Wang, Tai; Yu, Ying; Zhang, Weiguang

    2016-10-07

    Chiral stationary phase-high performance liquid chromatography coupled with various detectors has been one of most commonly used methods for analysis and separation of chiral compounds over the past decades. Various detectors exhibit different characteristics in qualitative and quantitative studies under different chromatographic conditions. Herein, a comparative evaluation of HPLC coupled with ultraviolet, optical rotation, refractive index, and evaporative light scattering detectors has been conducted for qualitative and quantitative analyses of metalaxyl racemate. Effects of separation conditions on the peak area ratio between two enantiomers, including sample concentration, column temperature, mobile phase composition, as well as flow rate, have been investigated in detail. In addition, the limits of detection, the limits of quantitation, quantitative range and precision for these two enantiomers by using four detectors have been also studied. As indicated, the chromatographic separation conditions have been slight effects on ultraviolet and refractive index detections and the peak area ratio between two enantiomers remains almost unchanged, but the evaporative light scattering detection has been significantly affected by the above-mentioned chromatographic conditions and the corresponding peak area ratios varied greatly. Moreover, the limits of detection, the limits of quantitation, and the quantitative ranges of two enantiomers with UV detection were remarkably lower by 1-2 magnitudes than the others. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Quantitative determination of eleutheroside B and E from Acanthopanax species by high performance liquid chromatography.

    Science.gov (United States)

    Kang, J S; Linh, P T; Cai, X F; Kim, H S; Lee, J J; Kim, Y H

    2001-10-01

    Reversed-phase high performance liquid chromatographic method was applied for the determination of eleutheroside B and E in the various Acanthopanax species collected in Korea. The stationary phase used was Zorbax 300 SB C18 and a mobile phase program was used, which started at 6% acetonitrile for 2 min, and then a linear gradient was operated for the next 18 min to 17% acetonitrile at a flow rate of 1.0 ml/min. The column effluent was monitored at UV 210 nm. Identification was carried out by comparing the retention time and the LC/MS spectrum of each peak corresponding to eleutheroside B and E from sample with those of standards. In general, the contents of eleutheroside B and E in stems were higher than those in roots. Acanthopanax species could be classified into two groups based upon the contents of eleutheroside B and E: one group contains no or very little eleutheroside B and another contains both eleutheroside B and E.

  20. The determination of bromazepam in plasma by reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Le Solleu, H; Demotes-Mainard, F; Vinçon, G; Bannwarth, B

    1993-08-01

    A reversed-phase high-performance liquid chromatographic method has been developed for the determination of bromazepam, an anxiolytic benzodiazepine, in plasma. After a single-step extraction from alkalinized plasma with diethyl-ether in the presence of an internal standard (alpha-hydroxy-triazolam), the residues were chromatographed on a reversed-phase Nova Pak 5 microns C18 column, with a mobile phase of acetonitrile-water-triethylamine (700:300:4, v/v/v) adjusted to pH 7.4 with orthophosphoric acid. The limit of detection was 50 ng ml-1, using a 20 microliters injection with UV detection at 240 nm. Between-day and within-day relative standard deviations were lower than 6%. Studies of drug stability during sample storage at -20 degrees C and at +4 degrees C showed no degradation of bromazepam. However, bromazepam seemed to be degraded at ambient temperature, without any influence of light. This method is applied to the determination of bromazepam plasma levels in analytical toxicology.

  1. Development of high-performance liquid chromatographic for quality and authenticity control of Chinese propolis.

    Science.gov (United States)

    Cui-ping, Zhang; Shuai, Huang; Wen-ting, Wei; Shun, Ping; Xiao-ge, Shen; Ya-jing, Li; Fu-liang, Hu

    2014-07-01

    A RP-high-performance liquid chromatography (HPLC) method was developed for quality control of Chinese propolis by simultaneous analysis of 12 flavonoids and 8 phenolic acids. The results showed that vanillic acid, rutin, myricetin, and luteolin were not detected in all of the analyzed propolis and poplar tree gum samples. The caffeic acid, ferulic acid and p-coumaric acid were not detected in poplar tree gum but were detected in propolis, which suggest that they are practical indexes of distinguishing propolis from poplar tree gum. The flavonoid profiles of poplar tree gum were found to be similar to those of propolis, which are dominated by pinobanksin, pinocembrin, 3-O-acetylpinobanksin, chrysin, and galangin. Therefore, the proposed method could be applied to exclude poplar tree gum from propolis with cafferic acid, ferulic acid, and p-coumaric acid as qualitative markers, and distinguish poplar source resin from other illegal substances, and evaluate the quality grading of poplar-type propolis with pinobanksin, pinocembrin, 3-O-acetylpinobanksin, chrysin, and galangin as qualitative and quantitative markers. © 2014 Institute of Food Technologists®

  2. Enantioselective high-performance liquid chromatographic determination of nicardipine in human plasma.

    Science.gov (United States)

    Uno, T; Ohkubo, T; Sugawara, K

    1997-09-26

    A sensitive method for the enantioselective high-performance liquid chromatography (HPLC) determination of nicardipine in human plasma is described. (+)-Nicardipine, (-)-nicardipine and (+)-barnidipine as an internal standard are detected by an ultraviolet detector at 254 nm. Racemic nicardipine in human plasma was extracted by a rapid and simple procedure based on C18 bonded-phase extraction. The extraction samples were purified and concentrated on a pre-column using a C1 stationary phase and the enantiomers of nicardipine are quantitatively separated by HPLC on a Sumichiral OA-4500 column, containing a chemically modified Pirkle-type stationary phase. Determination of (+)- and (-)-nicardipine was possible in a concentration range of 5-100 ng ml(-1) and the limit of detection in plasma was 2.5 ng ml(-1). The recoveries of (+)- and (-)-nicardipine added to plasma were 91.4-98.4% and 93.3-96.7%, respectively, with coefficients of variation of less than 9.0 and 9.4% respectively. The method was applied to low level monitoring of (+)- and (-)-nicardipine in plasma from healthy volunteers.

  3. Quantitation of aflatoxins in walnut kernels by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Kabak, Bulent

    2014-01-01

    A total of 85 walnut samples collected between October 2012 and April 2013 in different provinces of Turkey were analysed for the presence of aflatoxins (AFs). The method involved methanol-water extraction, clean-up with immunoaffinity columns and a sensitive high-performance liquid chromatography coupled with fluorescence detection after post-column derivatisation. The method was validated for selectivity, linearity, trueness, precision, limit of detection and limit of quantification (LOQ), which met the performance criteria as set by EC regulation No. 401/2006. LOQs were 0.07, 0.04, 0.09 and 0.05 µg kg(-1) for AFB1, AFB2, AFG1 and AFG2, respectively. AFs were present in 9.4% of walnut samples (8/85) at total AFs levels ranging from 0.09 to 15.4 µg kg(-1). Only one of eight walnut samples exceeded the European Union limit of 2 and 4 µg kg(-1) for AFB1 and total AFs, respectively.

  4. Rapid analysis of estrogen receptor heterogeneity by chromatofocusing with high-performance liquid chromatography.

    Science.gov (United States)

    Hutchens, T W; Wiehle, R D; Shahabi, N A; Wittliff, J L

    1983-08-26

    Chromatofocusing principles have been utilized to develop a high-performance liquid chromatographic technique for the rapid and routine analysis of steroid receptor heterogeneity. Two anion-exchange columns (SynChropak AX-300 and AX-500) were compared for analytical and preparative chromatofocusing of estrogen receptor components. As many as ten different [125I]iodoestradiol-labeled binding proteins were identified in cytosols prepared from mammary gland and uterus. Estrogen receptors were well separated from other cytosolic proteins and recovery of activity routinely exceeded 90%. Parallel analyses of these cytosols to determine receptor size and shape indicated that HPLC chromatofocusing can be used effectively to study receptor isoforms with Stokes radii ranging from 30 A to greater than 70 A. In contrast to isoelectric focusing, this technique is compatible with the inclusion of a commonly used receptor-stabilizing agent, sodium molybdate. Inclusion of molybdate during chromatofocusing of molybdate-stabilized receptor allowed the identification of two acidic receptor species not previously reported.

  5. Determination of Benzalkonium Chloride in Nasal Drops by High-Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Danijela A. Kostić

    2012-01-01

    Full Text Available A high-performance liquid chromatography (HPLC system was used in the reversed phase mode for the determination of benzalkonium chloride (BKC in nosal drops. A Chromolit RP-18e, 100 x 4.6, (UM6077/035 column was used at 40 °C. The mobile phase, optimized through an experimental design, was a 70:30 (v/v mixture of 0.057M Na-heksansulphonate potassium, dihydrogen orthophosphate buffer (pH 2.9 and acetonitrile, pumped at a flow rate of 1.75 mL/min at maintaining column temperature at 40 °C. Maximum UV detection was achieved at 215 nm. The method was validated in terms of selectivity, linearity, repeatability, precision and accuracy. The method was successfully applied for the determination of BKC in a pharmaceutical formulation of nasal drop solution without any interference from common excipients and drug substance. All the validation parameters were within the acceptance range, concordant to ICH guidelines.

  6. Determination of benzalkonium chloride in viscous ophthalmic drops of azithromycin by high-performance liquid chromatography *

    Science.gov (United States)

    Shen, Yan; Xu, Sheng-jie; Wang, Shi-chun; Tu, Jia-sheng

    2009-01-01

    A high-performance liquid chromatography (HPLC) system was used in the reversed phase mode for the determination of benzalkonium chloride (BKC) in azithromycin viscous ophthalmic drops. A Venusil-XBP(L)-C18 (150 mm×4.6 mm, 5 μm) column was used at 50 °C. The mobile phase consisted of a mixture of methanol-potassium phosphate (16:5, v/v). Two sample preparation methods were compared. The results suggested that, compared with an extraction procedure, a deproteinization procedure was much quicker and more convenient. Using the deproteinization procedure for sample preparation, calibration curves were linear in the range 5.0~50 μg/ml. The within-day and inter-day coefficients of variation were less than 10%. The average recoveries were determined as 96.70%, 98.52%, and 97.96% at concentrations of 10.0, 30.0, and 50.0 μg/ml, respectively. Variability in precision did not exceed 5%. In conclusion, this HPLC method using a simple sample treatment procedure appears suitable for monitoring BKC content in azithromycin viscous ophthalmic drops. PMID:19946951

  7. High-performance liquid chromatographic analysis and pharmacokinetics of terazosin in healthy volunteers.

    Science.gov (United States)

    Kang, B C; Yang, C Q; Rhee, J E; Suh, O K; Shin, W G

    2001-01-01

    A high-performance liquid chromatographic (HPLC) analysis of terazosin in 1 ml of human plasma was developed using prazosin as an internal standard. The plasma sample was extracted with dichloromethane and ethylether and a 100-microl aliquot was injected onto the reversed-phase column. The mobile phase, 0.02 M sodium phosphate buffer:acetonitrile:tetrahydrofuran = 720:220:60 (v/v/v), was run at a flow rate of 0.8 ml/min and the column effluent was monitored using a florescence detector set at 370 and 250 nm for the emission and excitation wave numbers, respectively. The retention times for terazosin and prazosin were approximately 6.4 and 9.8 min, respectively, and the coefficients of variation of terazosin were generally low, below 6.4%. The present HPLC method was successful for the pharmacokinetic study of terazosin in healthy volunteers. Following oral administration of terazosin, 2 mg, to 20 healthy male volunteers, the area under the plasma concentration-time curve from time zero to time infinity was 421 +/- 71.8 ng h/ml and terminal half-life was 9.83 +/- 1.29 h.

  8. Determination of Residual Monomers in Polycarboxylate Superplasticizer Using High Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    GUO Liping; WANG Shaofeng; ZHANG Anfu; LEI Jiaheng; DU Xiaodi

    2011-01-01

    A procedure was developed for the determination of residual monomers in polycarboxylate superplasticizer (PCs) by reversed-phase high performance liquid chromatography (RP-HPLC). Four kinds of residual monomers were well separated and determined on a SinoChrom ODS-BP (C18) column with mobile phases composed of acetonitrile and phosphate buffer solution. The monomers were detected by UV detector at 205 nm and quantitatively analyzed with an external standard method. For those residual monomers, the linear response ranged from 4.0× 10-6 mol·L-1 to 2.0× 10-3 mol·L-1. The determination limit of acrylic acid, sodium methylallyl sulfonate and 2-Acrylamido-2-methylpropane sulfonic acid was 0.02× 10-5 mol·L-1, while that of methoxy-polyethylene glycol monoacrylate was 0.1 × 10-5 mol· L-1. The relative standard deviation (RSD) of high concentration samples was less than 1%, while that of the low concentration samples was between 1%-4%. The standard (additional) recovery ratio was 97.4% -104.2%.

  9. [Simultaneous determination of 10 synthetic colorants in cosmetics by high performance liquid chromatography].

    Science.gov (United States)

    Liu, Haishan; Qian, Xiaoyan; Lü, Chunhu; Zhu, Xiaoyu; Chen, Xiaomei; Mo, Weimin

    2013-11-01

    A high performance liquid chromatographic method was developed for the simultaneous determination of 10 synthetic colorants in cosmetics. The cosmetics were extracted by the ultrasonic technique with tetrahydrofuran (THF), dimethyl sulfoxide (DMSO) and methanol sequentially. Then the extracts were centrifuged for purification and separated on an Eclipse XDB-C18 column (150 mm x 4.6 mm, 5 microm) with gradient elution by acetonitrile and 0.02 mol/L ammonium acetate (pH 4.60, adjusted with acetic acid). A diode array detector was used to determine the colorants with the wavelengths ranging from 417 nm to 640 nm. The linear relationships of the 10 colorants between the peak areas and the mass concentrations were obtained in the range of 0.5-20.0 mg/L (r > 0.999). The limits of quantitation ranged from 10 to 20 mg/kg. The average recoveries at three concentration levels ranged from 92.9% to 108.8% with the relative standard deviations in the range of 0.5% to 6.1% (n = 6). The method is simple, rapid and sensitive. It is suitable for the simultaneous determination of the 10 colorants in the oil cosmetics, cream cosmetics and powder cosmetics.

  10. Simultaneous characterization and quantification of 17 main compounds in Rabdosia rubescens by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Sen Guo

    2017-04-01

    Full Text Available Rabdosia rubescens is a healthy herbal tea and well-known Chinese medicinal herb. To evaluate the quality of R. rubescens from China, a high performance liquid chromatography method with dual-wavelength detection was developed and validated. The method was successfully applied for the simultaneous characterization and quantification of 17 main constituents from four different cultivation regions in China. Under optimal conditions, analysis was performed on a Luna C-18 column and gradient elution with a solvent system of acetonitrile and 0.5% (v/v acetic acid–water at a flow rate of 1.0 mL/min and wavelength of 220 nm and 280 nm. All standard calibration curves exhibited good linearity (r2 > 0.9992 within the test ranges. The precision was evaluated by intraday and interday tests, which revealed relative standard deviation values within the ranges of 0.57–2.35% and 0.52–3.40%, respectively. The recoveries were in the range of 96.37–101.66%. The relative standard deviation values for stability and repeatability were < 5%. The contents of some compounds were low and varied with different cultivars. The proposed method could serve as a prerequisite for quality control of R. rubescens materials and products.

  11. [Determination of six pesticides in milk using cloud point extraction-high performance liquid chromatography].

    Science.gov (United States)

    Wang, Jian; Cui, Yanmei; Liu, Wei; Yang, Mingmin; Chen, Jianbo

    2007-11-01

    The feasibility of employing cloud point extraction (CPE) as extraction and preconcentration method for the recovery of herbicides from milk samples followed by high performance liquid chromatography (HPLC) analysis is demonstrated. An aqueous surfactant solution containing 60 g/L Tween 20 or Triton X-100 was heated with an appropriate concentration of (NH4)2SO4 or NaCl for the extraction of herbicides. The extract was analyzed by HPLC subsequently. Six herbicides in milk were analyzed simultaneously. The results showed that the linear dynamic ranges of detection were 20 - 10 000 microg/L for tralkoxydim, metribuzin and bromoxynil, 30 - 10 000 microg/L for mefenacet, and 50 - 10 000 microg/L for bensulfuron-methyl and nicosulfuron. The correlation coefficients were 0.998 1 - 0.999 7. The average recoveries of the six herbicides ranged from 85.09% to 96.74%. The relative standard deviations for the six herbicides were in the range of 1.90% - 3.98%. The limits of detection for the six pesticides were lower than the maximum residue limits (MRL) of China. The results indicate that the method is easier, faster, sensitive and produces less pollutants.

  12. Analysis of ciprofloxacin by a simple high-performance liquid chromatography method.

    Science.gov (United States)

    Wu, Shihn-Sheng; Chein, Chih-Yuan; Wen, Yen-Hsia

    2008-07-01

    A simple and sensitive high-performance liquid chromatographic method is described for the quantitative analysis of ciprofloxacin in pharmaceuticals and human plasma. The method employs reversed-phase chromatography using an RP-C18 column with an isocratic mobile phase of acetonitrile-2% acetic acid aqueous solution (16:84, v/v), umbelliferone as an internal standard, and a flow rate of 1.0 mL/min. The UV detector is set at 280 nm. The limit of detection is 0.25 microM (S/N = 3, injection volume = 10 microL). The regression equations are linear (r > 0.9999) over a range between 0.51 approximately 130 microM for the pharmaceutical analysis of ciprofloxacin and 0.51 approximately 64.8 microM for the biological analysis of ciprofloxacin in human plasma. The intra- and inter-day relative standard deviation and relative error are less than 3.39% and 5.71%, respectively. All the recoveries are greater than 93.8%. This method is successfully applied in a pharmacokinetic study of a volunteer who receives a 500 mg ciprofloxacin tablet.

  13. Determination of folates in seaweeds by high-performance liquid chromatography.

    Science.gov (United States)

    Rodríguez-Bernaldo de Quirós, A; Castro de Ron, C; López-Hernández, J; Lage-Yusty, M A

    2004-04-02

    A reversed-phase high-performance liquid chromatography (HPLC) method, with a combination of fluorescence and ultraviolet detectors, to determine the folate forms present in commercial macroalgae products form northwest Spain as part of nutritional studies in dehydrated and canned seaweeds is reported. The method includes extraction of folates from seaweed by heat treatment, deconjugation of folate polyglutamates by incubation with hog kidney conjugase and purification by solid-phase extraction (SPE) with strong anion-exchange (SAX) cartridges. Separation was achieved with a Tracer Extrasil ODS 5 microm 25 cm x 0.4 cm column using acetonitrile and potassium phosphate buffer (pH 2.21 as mobile phase. Good results were obtained with respect to repeatability (relative standard deviation (R.S.D.) or = 90.80%). The amount of folate (as folic acid) in the six species ranged from 61.4 to 161.6 microg per 100 g dry mass. In all the seaweeds studied (Himanthalia elongata, Laminaria ochroleuca, Palmaria spp., Undaria pinnatifida and Porphyra spp. and Saccorhiza polychides) the single most abundant form is 5-CH3-H4-folate, except Porphyra and Himanthalia.

  14. Simultaneous determination of thiamine and riboflavin in edible marine seaweeds by high-performance liquid chromatography.

    Science.gov (United States)

    Sánchez-Machado, D I; López-Cervantes, J; López-Hernández, J; Paseiro-Losada, P

    2004-03-01

    This study presents a high-performance liquid chromatography (HPLC) method for simultaneous determination of thiamine and riboflavin and the results of its application to a number of edible seaweeds that are sampled in dried form (Himanthalia elongata, Laminaria ochroleuca, Undaria pinnatifida, Palmaria sp., and Porphyra sp.) or as canned food (H. elongata and Saccorhiza polyschides). Samples are prepared by acid and enzymatic hydrolysis. Optimized conditions for reversed-phase HPLC with fluorescence detection are as follow: column, Kromasil 100 C18; column temperature, 35 degrees C; mobile phase, a 72:28 (v/v) mixture of 0.005 M ammonium acetate (pH 6.7)-methanol; and flow rate, 1.35 mL/min. With these conditions, recovery is 95.52% for thiamine and 90.08% for riboflavin, and the method precision (relative standard deviation) is 2.66% for thiamine and 2.21% for riboflavin. On a dry weight basis, thiamine contents range from 0.14 microg/g in dried H. elongata to 2.02 microg/g in dried Porphyra and riboflavin contents from 0.31 microg/g in canned H. elongata to 6.15 microg/g in dried Porphyra.

  15. Simultaneous determination of eleven characteristic lignans in Schisandra chinensis by high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Junyang Hu

    2013-01-01

    Full Text Available Background: Schisandra chinensis, one of the well-known traditional Chinese herbal medicines, is derived from the dry ripe fruits of Schisandra chinensis (Turcz. Baill. according to the 9th China Pharmacopeia. Lignans are the main components isolated from extracts of S. chinensis and their content varies depending on where S. chinensis was collected. We have established a qualitative and quantitative method based on the bioactive lignans for control of the quality of S. chinensis from different sources. Materials and Methods: To develop a high-performance liquid chromatography method, an Elite ODS C18 column (250 mm Χ 4.6 mm, 5μm at a column temperature of 30°C and flow rate of 1.0ml/min using acetonitrile (A and water (B as the mobile phase with a linear gradient and the peaks were monitored at 217 nm. Results: All calibration curves showed good linearity (r ≥ 0.9995 within test ranges. This method showed good repeatability for the quantification of these eleven components in S. chinensis with intra- and inter-day relative standard deviations less than 0.43% and 1.21%, respectively. In the recovery test, results of accuracy ranged from 99.51% to 101.31% with RSD values less than 2.68%, Conclusion: The validated method can be successfully applied to quantify the eleven investigated components in 22 samples of S. chinensis from different sources.

  16. Preparation and Characterization of a New Quercetin-bonded Stationary Phase for High Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    李来生; 方奕珊; 陈红; 张杨

    2012-01-01

    A quercetin-bonded silica gel stationary phase (QUSP) containing natural flavonoid ligand was first prepared via γ-glycidoxypropyltrimethoxysilane (KH-560) as a coupling reagent for high-performance liquid chromatography. Its chemical structure was characterized by Fourier infrared spectroscopy, elemental analysis, thermal thermogravimetry and 13C cross polarization/magic angle spinning nuclear magnetic resonance (CP/MAS NMR). The chromatographic property of QUSP was systematically evaluated by using neutral, basic and acidic aromatic com- pounds as probes. In order to clarify its retention mechanism, a comparative study of QUSP with conventional oc- tadecylsilyl-bonded stationary phase (ODS) was also carried out under the same conditions. The results showed that the new quercetin-bonded phase exhibited an excellent reversed-phase chromatographic property with relatively weak hydrophobicity. However, it has an advantage over ODS in the fast separation of polar aromatic compounds because the quercetin ligand could provide various sites besides hydrophobicity, such as hydrogen bonding, dipole-dipole, n-n staking and charge transfer interactions. QUSP was performed in the baseline separations of ion- ized polar basic or acidic compounds, including pyridines, anilines, pyrimidines, purines and phenols with symmet- ric peak shape in common mobile phases without buffer salt within relatively short time. The natural ligands from herbs are readily available and contain a variety of active sites, which facilitate the exploration of industrial chromatographic separation materials for green products.

  17. High performance liquid chromatography determination of theobromine and caffeine in cocoa beans gamma irradiated

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Anderson D.B. [Faculdade de Engenharia de Varginha, MG (Brazil); Mansur Neto, Elias [Minas Gerais Univ., Belo Horizonte, MG (Brazil)

    1997-12-01

    Irradiation is a processing technology that has been shown to be a wholesome process by many scientific studies conducted worldwide during the past 40 years, which has been approved by 37 countries. Irradiated foods have been studied so extensively, that the effects on foods are better understood than any other preservation process, including food freezing and dehydration. Cocoa beans has been commercially irradiated in countries such as Ivory Coast and Argentina. The alkaloids theobromine and caffeine are responsible for the mildly stimulating properties and bitter taste of cocoa and chocolate products. Previously fermented dried and nonfumigated cocoa beans were irradiated at doses of 0, 5.0, 10.0 and 20.0 kGy using Co-60 gamma rays. The samples were analysed for determining theobromine and caffeine contents in the cocoa beans by TIMBIE et al. (1978) high performance liquid chromatography (HPLC) method. Boiling water extracts were cooled, centrifuged and injected into the chromatograph. Theobromine and caffeine were quantitated at 273 nm and showed the tendency of decreasing as the dose of radiation increases. Theobromine and caffeine ranged from 42.3 to 37.1 mg/g and from 7.60 to 6.13 mg/g. respectively from 0 to 20.0 kGy. These results were discussed in relation to the possible acceptance of radiosterization of cocoa beans commercially up to the dose of 20.0 kGy. (author). 10 refs., 1 tab.

  18. Determination of mitomycin C in human aqueous humor and serum by high-performance liquid chromatography.

    Science.gov (United States)

    Li, W Y; Seah, S K; Koda, R T

    1993-09-08

    Mitomycin C (MMC) is used in the treatment of disseminated adenocarcinoma of the stomach and pancreas and is used in ophthalmology as adjunctive therapy in trabeculectomy. Since only small volumes of aqueous humor are available for analysis, a sensitive method requiring limited sample preparation was developed. An internal standard, 4-aminoacetophenone, was added to aqueous humor specimens, and the solution was directly injected into the high-performance liquid chromatographic (HPLC) column. The use of a short 50-mm C18 reversed-phase column gave adequate resolution of peaks with improved sensitivity. The method was applicable for determination of MMC in serum, although solid-phase extraction for sample clean-up was required prior to injection into the HPLC column, and analytical columns of 150-250 mm were necessary for adequate resolution of peaks. The method has been validated and is linear from 6.25 to 50 ng/ml in aqueous humor and from 10 to 500 ng/ml in serum.

  19. QUANTITATIVE ANALYSIS OF RAW MATERIAL OF TETRACYCLINE AND ITS RELATED SUBSTANCES BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    NABILA PERVEEN

    2006-01-01

    Full Text Available An isocratic method for the analysis of tetracycline (TC by high performance liquid chromatography (HPLC using polystyrene-divinylbenzene copolymer packing material is described. The method allows the complete separation of TC, 4-epitetracycline, anhydrotetracycline (ATC, 4-epianhydrotetracycline (EATC. A fermentation impurity, 2-acetyl-2-decarboxamidetetracycline is also resolved from TC. The mobile phase combines tert.-butanol, water and phosphate buffer, tetrabutylammonium sulphate and sodium ethylenediaminetetraacetate at pH 9.0 for elution at a temperature of 60°C. Among the organic modifiers examined, only tetrahydrofuran and tert.-butanol gave good results. For practical reasons, tert.-butanol was retained as the final organic modifier. The preliminary experiments were carried out on polystyrene-divinylbenzene copolymer packing material (PRP-I and PLRP-S columns. The selectivity of the columns is comparable. PLRP-S column was chosen as it shows better separation of tetracycline – anhydrotetracycline. The method was used to analyse the commercial samples.

  20. Determination of organic mercury species in soils by high-performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Hempel, M; Hintelmann, H; Wilken, R D

    1992-03-01

    Reversed-phase high-performance liquid chromatography with ultraviolet detection was optimized for the simultaneous separation and quantification of nine organic mercury compounds: methyl-, ethyl-, phenyl-, methoxyethyl-, ethoxyethyl-, benzoic and tolylmercury, mersalylic acid and nitromersol. The nine compounds were successfully separated on octadecylsilane columns (200 x 3 mm i.d.) by gradient elution with a methanol-water mixture ranging from 30 to 50% v/v. The detection limits for the various compounds are in the range 7.0-95.1 micrograms dm-3. For the extraction of five organomercurials from spiked soils, eight different extraction solutions were tested to differentiate between the total content and the available/soluble fraction of the analytes. Ammonium acetate solutions (1 mol dm-3) and water proved to be suitable agents for the estimation of the available and soluble fractions of methyl-, ethyl-, benzoic, methoxyethyl- and ethoxyethylmercury. For the determination of the total content of methyl- and benzoic mercury in soils, solutions of potassium iodide (1 mol dm-3)-ascorbic acid (0.1 mol dm-3) and oxalic acid (1 mol dm-3) provided recoveries in the ranges 53-81%. None of the solutions tested is suitable for the extraction of ethyl-, methoxyethyl- and ethoxyethylmercury.

  1. [Determination of clavulanic acid residue in milk by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Yang, Gang; Huang, Xianhui; Guo, Chunna; Fang, Qiuhua; He, Limin

    2012-06-01

    An analytical method was developed for the determination of clavulanic acid (CLAV) in milk by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). A 2 g milk sample was deproteinized by ethanol. The supernatant was transferred into a pear-shaped bottle to be evaporated to about 0.5 mL, and the residue was dissolved with ammonium acetate solution. The sample was determined by HPLC-MS/MS after the purification. The chromatographic separation was achieved on a Luna 5u C8 column using 0.1% formic acid in water and acetonitrile as mobile phases with gradient elution. The identification of CLAV was carried out by MS/MS equipped with electrospray ionization in negative scanning and multiple reaction monitoring (MRM) modes. Matrix-matched calibration standard was used for the quantification. The calibration curve showed perfect linear in the range of 10 - 400 microg/kg with the correlation coefficient of 0.999. The limit of detection (LOD, S/N > or = 3) was 10 microg/kg in milk, and the limit of quantification (LOQ, S/N > or = 10) was 20 microg/kg. The mean recoveries varied from 80.00% to 91.25% at the four spiked levels of LOQ, 1/2MRL (the maximum residue limit), MRL, and 2MRL with the relative standard deviations of 5.60% -8.77%. In conclusion, the established method can be applied for the determination of CLAV residues in milk.

  2. Biogenic amines in table olives. Analysis by high-performance liquid chromatography.

    Science.gov (United States)

    Hornero-Méndez, D; Garrido-Fernández, A

    1994-09-01

    Biogenic amines in fermented vegetables have scarcely been studied. Available data show that in table olives and fermented cucumbers their presence is rare and any determinations made have been restricted mainly to histamine. However, some microorganisms, especially those related to spoilage, found in the fermentation brines of such products may have amino acid decarboxylase activity and give rise to biogenic amines by unusual processes. A method for the simultaneous determination of eight biogenic amines (tryptamine, beta-phenylethylamine, putrescine, cadaverine, histamine, tyramine, spermidine, and spermine) has been developed to study their occurrence in fermented vegetables in more detail. The method consists of extraction of the amines from olive paste with 5% m/v trichloracetic acid and successive transfers into water-saturated n-BuOH and 0.1 mol l-1 HCl. An aliquot of this mixture is dried and derivatized with dansyl chloride. The dansyl derivatives are then analysed by high-performance liquid chromatography. Special emphasis has been given to optimization of the n-BuOH and 0.1 mol l-1 HCl extractions and to the derivatization conditions. By applying this method to the analysis of spoilt olives, the presence of some biogenic amines has been demonstrated. Thus a new method for monitoring the presence of biogenic amines during the fermentation of olives and for detecting anomalous fermentations is envisaged.

  3. Quality Evaluation of Potentilla fruticosa L. by High Performance Liquid Chromatography Fingerprinting Associated with Chemometric Methods.

    Directory of Open Access Journals (Sweden)

    Wei Liu

    Full Text Available The present study was performed to assess the quality of Potentilla fruticosa L. sampled from distinct regions of China using high performance liquid chromatography (HPLC fingerprinting coupled with a suite of chemometric methods. For this quantitative analysis, the main active phytochemical compositions and the antioxidant activity in P. fruticosa were also investigated. Considering the high percentages and antioxidant activities of phytochemicals, P. fruticosa samples from Kangding, Sichuan were selected as the most valuable raw materials. Similarity analysis (SA of HPLC fingerprints, hierarchical cluster analysis (HCA, principle component analysis (PCA, and discriminant analysis (DA were further employed to provide accurate classification and quality estimates of P. fruticosa. Two principal components (PCs were collected by PCA. PC1 separated samples from Kangding, Sichuan, capturing 57.64% of the variance, whereas PC2 contributed to further separation, capturing 18.97% of the variance. Two kinds of discriminant functions with a 100% discrimination ratio were constructed. The results strongly supported the conclusion that the eight samples from different regions were clustered into three major groups, corresponding with their morphological classification, for which HPLC analysis confirmed the considerable variation in phytochemical compositions and that P. fruticosa samples from Kangding, Sichuan were of high quality. The results of SA, HCA, PCA, and DA were in agreement and performed well for the quality assessment of P. fruticosa. Consequently, HPLC fingerprinting coupled with chemometric techniques provides a highly flexible and reliable method for the quality evaluation of traditional Chinese medicines.

  4. Quantitation of meloxicam in the plasma of koalas (Phascolarctos cinereus) by improved high performance liquid chromatography.

    Science.gov (United States)

    Kimble, Benjamin; Li, Kong Ming; Govendir, Merran

    2013-01-01

    An improved method to determine meloxicam (MEL) concentrations in koala plasma using reversed phase high performance liquid chromatography equipped with a photo diode array detector was developed and validated. A plasma sample clean-up step was carried out with hydrophilic- lipophilic copolymer solid phase extraction cartridges. MEL was separated from an endogenous interference using an isocratic mobile phase [acetonitrile and 50 mM potassium phosphate buffer (pH 2.15), 45 : 55 (v : v)] on a Nova-Pak C18 4-µm (300 × 3.9 mm) column. Retention times for MEL and piroxicam were 8.03 and 5.56 min, respectively. Peak area ratios of MEL to the internal standard (IS) were used for regression analysis of the calibration curve, which was linear from 10 to 1,000 ng/mL (r(2) > 0.9998). Average absolute recovery rates were 91% and 96% for MEL and the IS, respectively. This method had sufficient sensitivity (lower quantitation limit of 10 ng/mL), precision, accuracy, and selectivity for routine analysis of MEL in koala plasma using 250-µL sample volumes. Our technique clearly resolved the MEL peak from the complex koala plasma matrix and accurately measured MEL concentrations in small plasma volumes.

  5. Identification and quantitation of asparagine and citrulline using high-performance liquid chromatography (HPLC).

    Science.gov (United States)

    Bai, Cheng; Reilly, Charles C; Wood, Bruce W

    2007-03-28

    High-performance liquid chromatography (HPLC) analysis was used for identification of two problematic ureides, asparagine and citrulline. We report here a technique that takes advantage of the predictable delay in retention time of the co-asparagine/citrulline peak to enable both qualitative and quantitative analysis of asparagine and citrulline using the Platinum EPS reverse-phase C18 column (Alltech Associates). Asparagine alone is eluted earlier than citrulline alone, but when both of them are present in biological samples they may co-elute. HPLC retention times for asparagine and citrulline were influenced by other ureides in the mixture. We found that at various asparagines and citrulline ratios [= 3:1, 1:1, and 1:3; corresponding to 75:25, 50:50, and 25:75 (microMol ml(-1)/microMol ml(-1))], the resulting peak exhibited different retention times. Adjustment of ureide ratios as internal standards enables peak identification and quantification. Both chemicals were quantified in xylem sap samples of pecan [Carya illinoinensis (Wangenh.) K. Koch] trees. Analysis revealed that tree nickel nutrition status affects relative concentrations of Urea Cycle intermediates, asparagine and citrulline, present in sap. Consequently, we concluded that the HPLC methods are presented to enable qualitative and quantitative analysis of these metabolically important ureides.

  6. Identification and Quantitation of Asparagine and Citrulline Using High-Performance Liquid Chromatography (HPLC

    Directory of Open Access Journals (Sweden)

    Cheng Bai

    2007-01-01

    Full Text Available High-performance liquid chromatography (HPLC analysis was used for identification of two problematic ureides, asparagine and citrulline. We report here a technique that takes advantage of the predictable delay in retention time of the co-asparagine/citrulline peak to enable both qualitative and quantitative analysis of asparagine and citrulline using the Platinum EPS reverse-phase C18 column (Alltech Associates. Asparagine alone is eluted earlier than citrulline alone, but when both of them are present in biological samples they may co-elute. HPLC retention times for asparagine and citrulline were influenced by other ureides in the mixture. We found that at various asparagines and citrulline ratios [= 3:1, 1:1, and 1:3; corresponding to 75:25, 50:50, and 25:75 (μMol ml–1/μMol ml–1], the resulting peak exhibited different retention times. Adjustment of ureide ratios as internal standards enables peak identification and quantification. Both chemicals were quantified in xylem sap samples of pecan [Carya illinoinensis (Wangenh. K. Koch] trees. Analysis revealed that tree nickel nutrition status affects relative concentrations of Urea Cycle intermediates, asparagine and citrulline, present in sap. Consequently, we concluded that the HPLC methods are presented to enable qualitative and quantitative analysis of these metabolically important ureides.

  7. Determination of Residual Acrylamide in Medical Polyacrylamide Hydrogel by High Performance Liquid Chromatography tandem Mass Spectroscopy

    Institute of Scientific and Technical Information of China (English)

    WEI-WEI LI; HUI LI; ZHI-FEI LIU; QUN QIAO

    2009-01-01

    Objective To determine residual acrylamide in medical polyacrylamide hydrogel by high performance liquid chromatography tandem mass spectroscopy (HPLC-MS). Methods After 13C3 labeled acrylamide was added, the sample was extracted with water and then cleaned up with ExtrelutTM 20. The polyaerylamide hydrogel sample and 20 clinical cases were analyzed by HPLC-MS/MS and isotope dilution quantifying technique in selected reaction monitoring (SRM) mode. Results Acrylamide was separated from polyacrylamide hydrogel. The concentration of acrylamide in polyacrylamide hydrogel ranged from 3.9×109 to 3.1×108g/L in the 20 clinical cases. The peak area was favorable linear and the range was up to 3 000 μg/L. The recovery rate was 103.1% with a relative standard deviation (RSD) of 6.20%, when the mark level was 50 μg/L. Conclusion HPLC-MS is a rapid, accurate, and sensitive method for the determination of residual acrylamide in medical polyacrylamide hydrogel.

  8. Determination of clomazone residues in soybean and soil by high performance liquid chromatography with DAD detection.

    Science.gov (United States)

    Hu, Jiye; Cao, Di; Deng, Zhubo

    2011-04-01

    A simple analysis method to detect clomazone residues in soybean and soil was developed using solid phase extraction coupled with high performance liquid chromatography with diode-array detection. The pesticide residues present in soybean and soil matrices were extracted with methanol-water and extracts purified with Florisil cartridges. The analytes from soybean and soil matrix were eluted with petroleum ether-acetic ether (10 mL, 95:5, v/v) and petroleum ether-acetic ether (2 mL, 95:5, v/v), respectively. The overall recovery of fortified soybean and soil at the levels of 0.01, 0.1 and 0.5 mg/kg ranged from 89.75% to 106.6%, and the coefficients of variation (CV) ranged from 1.68% to 4.93% (n = 3). The limit of quantification (LOQ) is 0.01 mg/kg. This method has been applied to the analysis of clomazone in real samples of soybean and soil. The dissipation of residue over the time in soil coincided with C = 1.189e(-0.0926t ) and the half-lives (T(1/2)) was 7.48 days. The final residue in soybean was lower than 0.01 mg/kg at harvest time. Direct confirmation of the analyte in real samples was achieved by gas chromatography-mass spectrometry.

  9. Detection of honey adulteration with starch syrup by high performance liquid chromatography.

    Science.gov (United States)

    Wang, Shaoqing; Guo, Qilei; Wang, Linlin; Lin, Li; Shi, Hailiang; Cao, Hong; Cao, Baosen

    2015-04-01

    According to saccharide profile comparison between starch syrups and pure honeys analysed through high performance liquid chromatography (HPLC), a characteristic peak was found at 15.25 min retention time in HPLC chromatogram of syrup, but no peak was observed at the same retention time in chromatogram of pure honeys. This characteristic peak for syrup was identified as an overlapping peak of oligosaccharides with more than 5 degree of polymerisation (DP) based on HPLC chromatogram comparison between starch syrup and a series of standard mono-, di- and oligosaccharides of 3-7 DP. Additionally syrup content correlated linearly with the height of the characteristic peak of syrup under different slope in two ranges 2.5-7.5% and 10-100%, respectively. Therefore, the characteristic peak at 15.25 min retention time can serve as a syrup indicator in HPLC analysis of the adulterated honeys. This new HPLC method for honey adulteration detection was further applied in an authenticity inspection on more than 100 commercial honeys. In addition to the improved accuracy of honey adulteration detection, the proposed HPLC method was simple, low cost and easy practice for honey product quality control by government department considering the popularity of HPLC device and technology. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Simultaneous Determination of Potassium Sorbate and Sodium Benzoate in Doogh Using High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    S. Sohrabvandi

    2015-09-01

    Full Text Available In this research, high performance liquid chromatography (HPLC as a simple and rapid technique was used for the determination of potassium sorbate and sodium benzoate in different brands of Doogh (typical Iranian drink based on fermented milk. The chromatographic separation was achieved with a C18 column (250 mm×4 I.D, 5 µm and one buffered mobile phase, acetate buffer (0.2 mol/L, pH4.4: acetonitrile (63:37 at a flow rate of 1 mL/min. The effluent was monitored at 235nm, respectively. The main affecting factors, such as Carrez solution amount, pH and centrifuge speed were optimized. Limits of detection (LODs were 1.823 for sorbic acid and 1.985 for benzoic acid. Relative standard deviations (RSDs for quintuplicate analyses were 4.4 for sorbic acid and 4.087 for benzoic acid. The method also showed good linearity in a range from 4 to 1000 mg/L with correlation coefficients (R2 of 0.990 for sorbic acid and 0.995 for benzoic acid. Recoveries for the two analytes were 80 for sorbic acid and 65 for benzoic acid. Comparing to the other techniques, the proposed method was significantly less time-consuming and had more acceptable accuracy, precision and interruption elimination in samples. The developed method was successfully used for the routine monitoring of benzoate and sorbate in Doogh.

  11. High-performance liquid chromatography of unmodified rosin and its applications in contact dermatology.

    Science.gov (United States)

    Sadhra, S; Gray, C N; Foulds, I S

    1997-10-24

    Rosin is a well recognised skin sensitiser and is also amongst the most common causes of occupational asthma. Due to its complex chemical composition, it is difficult to isolate its many components and this has hindered progress in the identification of the specific respiratory and contact allergens it contains. This paper reports the application of high-performance liquid chromatography and other analytical techniques to the isolation and identification of contact allergens in complex mixtures such as rosin. HPLC methods were developed in order to isolate as many rosin components as possible and these were then patch tested on rosin sensitive individuals. The structure of the most dermatologically active component was then determined using mass spectrometry, nuclear magnetic resonance and infrared techniques. An HPLC method has also been developed which will enable the identification of rosin in commercial products, providing a valuable tool for determining the cause of rosin contact allergy. Furthermore, mass spectral data for the common abieitic-type resin acids are compiled which were used to confirm the identification of the HPLC resin acid peaks and have not been reported previously.

  12. Determination of meropenem levels in human serum by high-performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Roth, Thomas; Fiedler, Stella; Mihai, Sidonia; Parsch, Hans

    2017-05-01

    Meropenem is a β-lactam broad-spectrum antibiotic and belongs to the subgroup of carbapenems. It is primarily used in intensive care units for intravenous treatment of severe infections. To avoid bacterial resistance or toxic side effects, the determination of serum meropenem concentration is highly advisable. A simple and fast method for the quantitative determination of meropenem in human serum using high-performance liquid chromatography with ultraviolet detection (HPLC/UV) was developed and validated. Meropenem was determined by an isocratic HPLC using a tris(hydroxymethyl)aminomethane buffer (pH 8.5; 15% methanol) as a mobile phase and UV detection at 300 nm, with a flow rate of 1.0 mL/min and an analysis time of 10 min. Chromatographic separation was performed on a Kinetex C18 column (5 μm, 150 × 4.6 mm). In order to remove undesired serum components, solid-phase extraction was used for sample preparation. Since meropenem is not stable in solution, sample and stock solution were stored at -80°C. After preparation, samples were stable at room temperature for at least 6 h. The calibration curve was linear from 3.5 to 200 mg/L with a correlation coefficient r(2) of 0.999. The method is accurate with an intra- and inter-assay precision <18.5%. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Determination by high-performance liquid chromatography of phenylbutazone in samples of plasma from fighting bulls.

    Science.gov (United States)

    Marti, M I González; Sánchez, González C I; Jiménez, Hernández; Cachán, García; Castro, de Cabo M J; Cuadrado, A L Garzón

    2002-03-25

    The purpose of this study was to investigate the possible presence of phenylbutazone in plasma samples from fighting bulls killed in 2nd and 3rd category bullrings in the province of Salamanca (Spain) in 1998, 1999 and 2000. For quantitative and qualitative determination, a high-performance liquid chromatograph was used, equipped with a photodiode-array detector and setting wavelengths at 240, 254 and 284 nm. The mobile phase optimized for the simultaneous detection of dexamethasone, betamethasone, flunixin and phenylbutazone, was 0.01 M acetic acid pH 3 in methanol (35:65 v/v) at a flow rate of 1 ml/min. Plasma samples were deproteinized with 400 microl of acetonitrile and 20 microl of the supernatant were injected directly into the chromatographic system equipped with a Lichrospher 60 RP select B column and guard column. For the quantitative analysis, standard calibration curves were made in a concentration range between 0.25 and 30 microg/ml, using betamethasone as internal standard. The retention time of phenylbutazone was 8.7 +/- 0.2 min and recovery was 83%. The detection and quantification limits were 0.016 and 0.029, respectively for A=240 nm. The study results show that 17 of the 74 samples analyzed in 1998, 18 of those from 1999 and 10 of those from 2000 were positive for phenylbutazone.

  14. [Simultaneous determination of four common nonprotein nitrogen substances in urine by high performance liquid chromatography].

    Science.gov (United States)

    Ma, Yuhua; Huang, Dongqun; Zhang, Rui; Xu, Shiru; Feng, Shun

    2013-11-01

    A high performance liquid chromatographic (HPLC) method was proposed to simultaneously determine four common nonprotein nitrogen substances, including creatine (Cr), creatinine (Cn), uric acid (Ua) and pseudouridine (Pu) in urine. After proteins being removed by acetone precipitation method, freeze drying and redissolving, the urine samples were analyzed by HPLC. Chromatographic separation was performed on a Waters RP18 Column (150 mm x 4.60 mm, 3.5 microm) in gradient elution mode using 10.0 mmol/L KH2PO4 solution (pH 4.78) and acetonitrile as mobile phases at a flow rate of 0.8 mL/min. The samples were detected at 220 nm. Rapid separation was achieved within 7 min. Under the optimized conditions, good linearities of four common nonprotein nitrogen substances were obtained in the range of 0.1-250 mg/L. The detection limits were 9.31 (Cr), 26.19 (Cn), 4.70 (Ua), an 6.30 (Pu) microg/L and the recoveries were in the range of 81%-111% with the relative standar deviations of 0.23%-2.78% (n = 3). The results demonstrate that this method is simple, rapid and accurate with good reproducibility, and can provide early diagnosis and preliminary judgment for type 2 diabetes mellitus (T2DM) patients with renal damage.

  15. Spectrophotometric and high performance liquid chromatographic methods for sensitive determination of bisphenol A.

    Science.gov (United States)

    Zhuang, Yafeng; Zhou, Meng; Gu, Jia; Li, Xiangmei

    2014-03-25

    A new spectrophotometric method for the determination of trace amounts of bisphenol A based on a diazotization-coupling reaction was developed. In acidic solution, clenbuterol was first diazotized with sodium nitrite, then coupled with bisphenol A to from an azo-compound [I] in NH3-NH4Cl buffer, which shows a maximum absorption at 410 nm. The effects of the amount of sodium nitrite, diazo reaction time, the amount of clenbuterol, coupling reaction time and coupling reaction temperature have been examined. Under the optional conditions, the determination of the linear range of bisphenol A is 0.24-8.4 μg/mL, correlation coefficient is 0.9905 and detection limit of this method is 0.15 μg/mL. The spectrophotometric method is simple, rapid, high sensitivity with better accuracy. High performance liquid chromatography (HPLC) technique combined with this new spectrophotometric method has been also developed for the measurement of bisphenol A. The analysis was achieved on a C18 column using water and methanol as a mobile phase and the detection was done spectrophotometrically at 410 nm. These reported methods were applied to the determination of bisphenol A in hot water in contact with commercially available table-water bottle samples.

  16. Methacrylate-bonded covalent-organic framework monolithic columns for high performance liquid chromatography.

    Science.gov (United States)

    Liu, Li-Hua; Yang, Cheng-Xiong; Yan, Xiu-Ping

    2017-01-06

    Covalent-organic frameworks (COFs) are a newfangled class of intriguing microporous materials. Considering their unique properties, COFs should be promising as packing materials for high performance liquid chromatography (HPLC). However, the irregular shape and sub-micrometer size of COFs synthesized via the traditional methods render the main obstacles for the application of COFs in HPLC. Herein, we report the preparation of methacrylate-bonded COF monolithic columns for HPLC to overcome the above obstacles. The prepared COF bonded monolithic columns not only show good homogeneity and permeability, but also give high column efficiency, good resolution and precision for HPLC separation of small molecules including polycyclic aromatic hydrocarbons, phenols, anilines, nonsteroidal anti-inflammatory drugs and benzothiophenes. Compared with the bare polymer monolithic column, the COF bonded monolithic columns show enhanced hydrophobic, π-π and hydrogen bond interactions in reverse phase HPLC. The results reveal the great potential of COF bonded monoliths for HPLC and COFs in separation sciences. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. A simple high-performance liquid chromatographic practical approach for determination of flurbiprofen

    Directory of Open Access Journals (Sweden)

    Muhammad Akhlaq

    2011-01-01

    Full Text Available A simple, rapid, sensitive, and specific high-performance liquid chromatography (HPLC assay for flurbiprofen has been developed and validated practically. The chromatography was conducted using Gemini C18 column (5 μm; 4.6 mm × 250 mm, Phenomenex, California, USA. The mobile phase containing disodium hydrogen phosphate solution (30 mM pH 7.0 and acetonitrile (50:50; and the isocratic flow rate of 1.0 ml/min were used in the current study. Detection was made at 247 nm. The calibration curve was linear (r ≥ 0.9996 over the concentration range of 5-50 mm/ml. Mean percentage (% recovery ± % relative standard deviation (RSD ranged from 97.07 ± 0.008 to 103.66 ± 0.013. Within-day and between-day precision were also in acceptable range of 98.83 ± 0.004 to 104.56 ± 0.009. In order to confirm the practical applicability of the method developed, flurbiprofen controlled release matrix tablets were subjected to the dissolution studies and the release rate was analyzed. The reported HPLC for flurbiprofen provides several advantages of simplicity, high specificity, accuracy, and very short run-cycle time. It is suggested that the method should be used for the routine quality control analysis of flurbiprofen pure drug and its dosage forms.

  18. Optimised determination of clobazam in human plasma with extraction and high-performance liquid chromatography analysis.

    Science.gov (United States)

    Bolner, A; Tagliaro, F; Lomeo, A

    2001-01-05

    The analysis of clobazam by high-performance liquid chromatography and UV detection is described herein. After adding an internal standard, 600 microl of plasma were extracted under basic conditions onto disposable cartridges packed with celite. The organic extract was then evaporated to dryness and the residue reconstituted in 200 microl of mobile phase. A 20 microl aliquot was injected into chromatograph. The HPLC system was equipped with an Ultrasphere C8 analytical column coupled with an UV detector set at 235 nm. The mobile phase was an acetate buffer 20 mM, pH 5.5, containing acetonitrile and triethylamine 70:30:0.01 (v/v); the flow-rate was 1.8 ml/min. Using this method, clobazam can be detected with a sensitivity limit of 6 ng/ml and the RSD% intra- and inter-assay were lower than 5%. For its ruggedness and reliability, the proposed method is particularly suitable for therapeutic drug monitoring in epilepsy.

  19. Quantitation of clobazam in human plasma using high-performance liquid chromatography.

    Science.gov (United States)

    Knapp, J; Bokník, P; Gumbinger, H G; Linck, B; Lüss, H; Müller, F U; Schmitz, W; Vahlensieck, U; Neumann, J

    1999-05-01

    A rapid and simple reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of clobazam concentrations in human blood samples is developed and validated. Solid-phase column extraction is performed to clean up blood samples before running the analytical HPLC system. The chromatography is isocratic with a mobile phase consisting of acetonitrile (20%, v/v), methanol (23%, v/v), and 0.1 M potassium hydrogen phosphate buffer (pH 3.6; 57%, v/v) at a constant flow rate of 2 mL/min. Clobazam is detected at 226 nm. Chromatography is completed within less than 25 min. The recovery rate is greater than 95% and linear over a wide range of drug concentrations. The intra-assay coefficient of variation percentage varies between 4.3 and 12. This method is used for therapeutic drug monitoring in patients undergoing antiepileptic therapy with clobazam. Plasma levels of clobazam ranged from 21 to 663 ng/mL. Other antiepileptic compounds, such as clonazepam and phenobarbital, did not interfere with the detection of clobazam.

  20. Determination of hexamethylenetetramine in foods by high-performance liquid chromatography (HPLC).

    Science.gov (United States)

    Lim, HoSoo; Kim, JungIm; Ko, KyungYuk; Kim, Meehye

    2014-01-01

    A simple and rapid method was developed and validated for the determination of hexamethylenetetramine (HMT) in foods. Samples were homogenised and extracted with methanol, followed by centrifugation. The resulting solution was filtered and injected into the high-performance liquid chromatograph (HPLC). HMT was separated using a Zorbax SCX-300 column coupled to a photodiode array detector. The calibration curve was linear in the range of 1.0-100 μg ml(-1), with good correlation coefficients (r(2) = 0.9992). The recoveries of HMT from foods spiked at levels of 10, 50 and 100 mg kg(-1) ranged from 91.6% to 103.8%, with relative standard deviations (RSDs) between 0.9% and 5.3%. The limit of detection and the limit of quantification of HMT were 0.3 and 1.0 mg kg(-1) based on three food matrixes (provolone cheese, glass noodle and tofu snack), respectively. Uncertainty associated with accuracy contributed mostly to the expanded uncertainty. No detectable levels of HMT were found in any of the samples retailed in Korea. The method was successful in determining HMT in foods.

  1. Detection of synthetic corticosteroids in bovine urine by chemiluminescence high-performance liquid chromatography.

    Science.gov (United States)

    Vázquez, B I; Feás, X; Lolo, M; Fente, C A; Franco, C M; Cepeda, A

    2005-01-01

    The development of a black market of chemical cocktails for illegal growth promotion in food-producing animals includes substances that are potentially dangerous for human health, such as synthetic corticosteroids. The potential presence of these residues in food makes it necessary to develop rapid and sensitive analytical methodologies to detect such substances, preferably in live animals before they arrive at the market. A chemiluminescence (CL) detection method for the determination of four synthetic corticosteroids (prednisolone, betamethasone, dexamethasone and flumethasone) in bovine urine has been developed. The proposed system, which does not need any derivatization procedure, offers an easy method well suited for routine research. Urine samples were homogenized with methanol:water (50:50, v/v) and centrifuged. The upper layer was collected and Strata X cartridges were used for cleaning up. The purified residues were evaporated to dryness and then redissolved in the mobile phase. Analysis of the extracts was performed using high-performance liquid chromatography with chemiluminescence detection, employing luminol as the CL reagent. The recovery curves, obtained at four spiking levels (different for each corticosteroid), showed that recoveries of at least 70% could be obtained for urine. The chemiluminescence detection procedure afforded satisfactory results with respect to sensitivity and the LOD and LOQ, taken as the first point of the regression curve, ranged from 4 ppb to 65 ppb. The maximum mean RSD was below 13% and below 15% for intra- and inter-day assay, respectively, in all cases.

  2. Simultaneous determination of ethinyl estradiol and drospirenone in oral contraceptive by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Viviane Benevenuti Silva

    2013-09-01

    Full Text Available A simple, rapid, economical and reliable high performance liquid chromatographic method has been developed and successfully applied in simultaneous determination of ethinyl estradiol and drospirenone in coated tablets. The HPLC method was performed on a LiChroCART® 100RP column (125x4 mm i.d., 5 µm with acetonitrile:water 50:50 (v/v as mobile phase, pumped at a flow rate of 1.0 mL.min-1. The fluorescence detection for ethinyl estradiol was made at λex= 280 nm and λem= 310 nm and a UV detection for drospirenone was made at 200 nm. The elution time for ethinyl estradiol and drospirenone were 4.0 and 5.7 min, respectively. The method was validated in accordance to USP 34 guidelines. The proposed HPLC method presented advantages over reported methods and is suitable for quality control assays of ethinyl estradiol and drospirenone in coated tablets.

  3. High-performance liquid chromatographic assay of free norepinephrine, epinephrine, dopamine, vanillylmandelic acid and homovanillic acid.

    Science.gov (United States)

    Gerlo, E; Malfait, R

    1985-09-13

    A procedure is described for the concurrent assay of free norepinephrine, epinephrine, dopamine, vanillylmandelic acid and homovanillic acid in physiological fluids using high-performance liquid chromatography with electrochemical detection. The column packing is an octadecyl-bonded silica. A single mobile phase containing 1-octanesulphonate is used for the assay of catecholamines and for the assay of the acidic metabolites. An efficient sample preparation scheme is presented for the isolation of the catecholamines and their acidic metabolites from the same sample aliquot. Catecholamines are extracted by ion exchange on small columns and adsorption on alumina, using dihydroxybenzylamine as an internal standard. Vanillylmandelic acid and homovanillic acid are recovered from the combined loading and washing effluents of the ion-exchange column by a solvent extraction procedure. Recovery of catecholamines averages 67%. The limit of detection for individual catecholamines is ca. 30 pg. Recoveries of vanillylmandelic acid and homovanillic acid average 77% and 87%, respectively. The use of the same mobile phase for the concurrent assay of catecholamines and their acidic metabolites considerably increases the throughput of samples in the chromatographic system by eliminating the time-consuming column-equilibration periods.

  4. Simultaneous determination of 11 preservatives in cosmetics by high-performance liquid chromatography.

    Science.gov (United States)

    Aoyama, Airin; Doi, Takahiro; Tagami, Takaomi; Kajimura, Keiji

    2014-10-01

    Preservatives prevent the growth of microorganisms in foods, pharmaceuticals and cosmetics. There exist numerous restrictions regarding the maximum allowable levels of preservatives in cosmetics. We analyzed 11 regulated preservatives in commercial cosmetics and manufacturers need to analyze their products for quality control purposes. However, methods used in previous studies to date have been inadequate for use by public institutions and manufacturers. Therefore, an effective, scalable method for the analysis of preservatives in cosmetics is required. We developed a novel method for the simultaneous determination of 11 regulated preservatives in cosmetics by high-performance liquid chromatography (HPLC). We applied the samples to a C18 column in a simple mobile phase (5 mmol/L ammonium formate solution and acetonitrile) with gradient elution at a flow rate of 1.0 mL/min at a single wavelength (230 nm). The correlation coefficients of the calibration curves were >0.997. The percent recoveries were 92.8-111.9% and the relative standard deviations were preservatives was >1.9. Because of the simple conditions for isolation and complete separation, the HPLC method can be effectively applied to the analysis of preservatives in commercially retailed cosmetics.

  5. High-Performance Liquid Chromatographic Ultraviolet Determination of Memantine Hydrochloride after In Vitro Transdermal Diffusion Studies

    Directory of Open Access Journals (Sweden)

    Sergio del Rio-Sancho

    2013-01-01

    Full Text Available The purpose of the present work was to validate an accurate and precise high-performance liquid chromatography (HPLC method involving ultraviolet detection for the quantitative analysis of memantine hydrochloride. In order to analyze a molecule with no chromophoric groups that could be detected by a UV/visible detector, it was necessary to extract the drug and to perform a dansylation reaction that enabled the UV/visible detection of the derivatized molecule. Separation was carried out with a 150 mm Kromasil C18 column at room temperature. The detection response, at 218 nm, was found to be linear in the concentration range from 0.5 to 50 μg/mL. The method was validated for specificity, linearity, precision, accuracy, limit of detection, limit of quantification, and robustness. The limit of detection (LOD was 0.144 μg/mL, and the limit of quantification (LOQ was 0.437 μg/mL. The dansylated memantine complex was stable for at least five days in all the conditions evaluated. The potential use of this method has been demonstrated by the quantification of memantine hydrochloride contained in samples from the study of its in vitro transdermal permeation.

  6. Preparation and characterization of high performance Schiff-base liquid crystal diepoxide polymer

    Energy Technology Data Exchange (ETDEWEB)

    Liu Huan; Fu Zien [Key Laboratory of Organic Polymer Material for Electronics, Guangzhou Institute of Chemistry, Chinese Academy of Sciences, P.O. BOX 1122, Guangzhou 510650 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Xu Kai, E-mail: xk@gic.ac.cn [Key Laboratory of Organic Polymer Material for Electronics, Guangzhou Institute of Chemistry, Chinese Academy of Sciences, P.O. BOX 1122, Guangzhou 510650 (China); Cai Hualun; Liu Xin [Key Laboratory of Organic Polymer Material for Electronics, Guangzhou Institute of Chemistry, Chinese Academy of Sciences, P.O. BOX 1122, Guangzhou 510650 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Chen Mingcai [Key Laboratory of Organic Polymer Material for Electronics, Guangzhou Institute of Chemistry, Chinese Academy of Sciences, P.O. BOX 1122, Guangzhou 510650 (China)

    2012-02-15

    Graphical abstract: The specific effects of highly conjugated Schiff-base moiety on thermal properties of the Schiff-base epoxy polymer were proposed first by us. From the point of view of structure-properties relationship, it can be considered that owing to the presence of the Schiff-base group, the high performance liquid crystal diepoxide polymer displayed improved thermal stability. Highlights: Black-Right-Pointing-Pointer In this work, we first proposed that specific effects of highly conjugated Schiff-base moiety on thermal properties of the Schiff-base epoxy polymer. Black-Right-Pointing-Pointer As one aim of this study, the thermal and thermal-oxidative stabilities of the thermosets were studied by TGA under nitrogen and under air. Black-Right-Pointing-Pointer The second aim of this study was to further understand the thermal degradation mechanism. Black-Right-Pointing-Pointer For thermal degradation mechanism of this polymer under nitrogen, TG-IR was used to investigate volatile components, and SEM/EDS was used to explore morphologies and chemical components of the residual char. Black-Right-Pointing-Pointer From the point of view of structure-properties relationship, it can be considered that owing to the presence of the Schiff-base group, the high performance liquid crystal diepoxide polymer displayed the improved thermal stability. - Abstract: A novel Schiff-base liquid crystal diepoxide polymer was prepared via a thermal copolymerization of a Schiff-base epoxy monomer (PBMBA) with a diamine co-monomer (MDA). We first proposed that specific effects of highly conjugated Schiff-base moiety on thermal properties of the Schiff-base epoxy polymer (PBMBA/MDA). Thermal degradation behavior of the polymer was characterized using thermogravimetric analysis (TGA) under nitrogen and under air, respectively. Thermogravimetric data obtained from TGA under nitrogen and under air reveal that PBMBA/MDA exhibits higher thermal stability compared with bisphenol-A type

  7. Evaluation between ultrahigh pressure liquid chromatography and high-performance liquid chromatography analytical methods for characterizing natural dyestuffs.

    Science.gov (United States)

    Serrano, Ana; van Bommel, Maarten; Hallett, Jessica

    2013-11-29

    An evaluation was undertaken of ultrahigh pressure liquid chromatography (UHPLC) in comparison to high-performance liquid chromatography (HPLC) for characterizing natural dyes in cultural heritage objects. A new UHPLC method was optimized by testing several analytical parameters adapted from prior UHPLC studies developed in diverse fields of research. Different gradient elution programs were tested on seven UHPLC columns with different dimensions and stationary phase compositions by applying several mobile phases, flow rates, temperatures, and runtimes. The UHPLC method successfully provided more improved data than that achieved by the HPLC method. Indeed, even though carminic acid has shown circa 146% higher resolution with HPLC, UHPLC resulted in an increase of 41-61% resolution and a decrease of 91-422% limit of detection, depending on the dye compound. The optimized method was subsequently assigned to analyse 59 natural reference materials, in which 85 different components were ascribed with different physicochemical properties, in order to create a spectral database for future characterization of dyes in cultural heritage objects. The majority of these reference samples could be successfully distinguished with one single method through the examination of these compounds' retention times and their spectra acquired with a photodiode array detector. These results demonstrate that UHPLC analyses are extremely valuable for the acquisition of more precise chromatographic information concerning natural dyes with complex mixtures of different and/or closely related physicochemical properties, essential for distinguishing similar species of plants and animals used to colour cultural heritage objects.

  8. Ionic liquids for improving the extraction of NSAIDs in water samples using dispersive liquid-liquid microextraction by high performance liquid chromatography-diode array-fluorescence detection.

    Science.gov (United States)

    Toledo-Neira, Carla; Álvarez-Lueje, Alejandro

    2015-03-01

    A rapid, sensitive and efficient analytical method based on the use of ionic liquids for determination of non-steroidal anti-inflammatory drugs (NSAIDs) in water samples was developed. High-performance liquid chromatography equipped with a diode array and fluorescence detector was used for quantification of ketoprofen, ibuprofen and diclofenac in tap and river water samples. This new method relies on the use of two ionic liquids with multiple functionalities: one functions as an extraction solvent (1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF6]), and the other changes the polarity in the aqueous medium (1-butyl-3-methylimidazolium tetrafluoroborate, ([BMIM][BF4]). Factors such as the type and volume of the ILs and dispersive solvent, sample volume, and centrifugation time were investigated and optimized. The optimized method exhibited good precision, with relative standard deviation values between 2% and 3%, for the three NSAIDs. Limits of detection achieved for all of the analytes were between 17 and 95 ng mL(-1), and the recoveries ranged from 89% to 103%. Furthermore, the enrichment factors ranged from 49 to 57. The proposed method was successfully applied to the analysis of NSAIDs in tap and river water samples.

  9. Ultrasound-assisted dispersive liquid-liquid microextraction combined with high-performance liquid chromatography-fluorescence detection for sensitive determination of biogenic amines in rice wine samples.

    Science.gov (United States)

    Huang, Ke-Jing; Wei, Cai-Yun; Liu, Wei-Li; Xie, Wan-Zhen; Zhang, Jun-Feng; Wang, Wei

    2009-09-18

    Ultrasound-assisted dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-fluorescence detection was used for the extraction and determination of three biogenic amines including octopamine, tyramine and phenethylamine in rice wine samples. Fluorescence probe 2,6-dimethyl-4-quinolinecarboxylic acid N-hydroxysuccinimide ester was applied for derivatization of biogenic amines. Acetonitrile and 1-octanol were used as disperser solvent and extraction solvent, respectively. Extraction conditions including the type of extraction solvent, the volume of extraction solvent, ultrasonication time and centrifuging time were optimized. After extraction and centrifuging, analyte was injected rapidly into high-performance liquid chromatography and then detected with fluorescence. The calibration graph of the proposed method was linear in the range of 5-500 microg mL(-1) (octopamine and tyramine) and 0.025-2.5 microg mL(-1) (phenethylamine). The relative standard deviations were 2.4-3.2% (n=6) and the limits of detection were in the range of 0.02-5 ng mL(-1). The method was applied to analyze the rice wine samples and spiked recoveries in the range of 95.42-104.56% were obtained. The results showed that ultrasound-assisted dispersive liquid-liquid microextraction was a very simple, rapid, sensitive and efficient analytical method for the determination of trace amount of biogenic amines.

  10. Development of the fingerprints for the quality evaluation of Viscum coloratum by high performance liquid chromatograp%Development of the fingerprints for the quality evaluation of Viscum coloratum by high performance liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    Yun-Li Zhao; Rong-Hua Fan; Hong-Xia Yuan; Miao Yu; Kai-Shun Bi; Zhi-Guo Yu

    2011-01-01

    A high-performance liquid chromatography coupled ultraviolet (HPLC-UV) method was developed for a chemical fingerprint analysis of Viscum coloratura. Eighteen peaks were selected as the common peaks and Homoeriodictyol-7-O-β-D-apiosiyl-(1→2)-β-D-glucoside

  11. Speciation of arsenic using chelation solvent extraction and high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Cathum, Shamil J.; Obenauf, Alison; Punt, Monique [SAIC Canada, Ottawa, Ontario (Canada); Brown, Carl E. [Emergencies Engineering Technology Office, Environmental Technology Centre, Environment Canada, Ottawa, Ontario (Canada)

    2007-02-15

    Research interest in speciation of arsenic stems from its species dependent behavior in the environment and in living organisms. The complexity of the matrix to be analyzed and low concentrations of target arsenic species that may be labile or difficult to chromatogram, indicate that a suitable pre-treatment methodology is required. This study investigated the usefulness of chelation solvent extraction - high performance liquid chromatography (CSE-HPLC) for the speciation of arsenic in water. It involved reacting arsenic with the chelant known for its affinity towards arsenic, followed by extraction, separation, and identification of the arsenic-chelant-arsenic complex. Arsenic species having different physicochemical properties were investigated. Species, such as, As{sub 2}O{sub 3}, As{sub 3}O{sub 5}, KH{sub 2}AsO{sub 4}, Na{sub 2}HAsO{sub 4}, and NaAsO{sub 2}were detected as a group of closely eluted peaks with different retention times and spectral properties, whereas, the organic arsenic species CH {sub 3}Na {sub 2}AsO {sub 3}, o-arsanilic acid, roxarson and triphenyl arsine separated quite well on the EnviroseP-CM HPLC column. Key method parameters, such as, type of HPLC column, composition of mobile phase and organic solvents affecting peak resolution and sensitivity were optimized. Real environmental matrices contaminated with arsenic were analyzed under varying wavelengths ({lambda}{sub max} = 190, 210, 220, 234, 244, and 282 nm), with good precision. Different arsenic species were detected in these samples with excellent background and signal-to-noise ratios demonstrating the robustness of the method. The detection limit, reproducibility, selectivity, accuracy, and dynamic range of the calibration curves were evaluated. (Abstract Copyright [2007], Wiley Periodicals, Inc.)

  12. Estimation of loxoprofen sodium dihydrate in tablets by reverse phase high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    R. Nanthakumar

    2016-09-01

    Full Text Available A simple and rapid reverse phase high performance liquid chromatographic (RP-HPLC method has been developed and validated for the estimation of loxoprofen sodium dihydrate (LSD in tablets. An isocratic HPLC analysis was performed on Phenomenex, Luna C18(2 (250 × 4.6 mm, 5μ column. The compound was separated with the mixture of 0.4% orthophosphoric acid and acetonitrile in the ratio of 45:55 (v/v as a mobile phase at a flow rate of 1.0 mL/min. UV detection was performed at 210 nm. Run time per sample was 8 min with the retention time of 4.9 min. The system suitability parameters, such as theoretical plate count, tailing and% RSD between six standard injections were within the limits. The method was validated according to ICH guidelines. The method was validated for specificity, precision, linearity, stability of sample solution, intermediate precision, robustness and accuracy. The stability of the sample solution was checked for 24 h at one hour intervals. The results show that the sample solution is stable for at least 24 h. Calibration plots were linear over the concentration range of 10–90 μg/mL as indicated by the correlation coefficient of 0.9992. The% RSD was 0.115 and 1.288 for system precision and method precision, respectively. The % RSD values for intermediate precision studies were less than 2%. The robustness of the method was evaluated by deliberately altering the chromatographic conditions and the results were adhered with the limits. The high recovery and low relative standard deviation confirm the suitability of the method for the estimation of loxoprofen sodium dihydrate in tablets.

  13. Pharmacokinetic study of mangiferin in rat plasma and retina using high-performance liquid chromatography

    Science.gov (United States)

    Hou, Yunlong; Fan, Shengjun; Gu, Yuanqin; Yu, Xuhui; Li, Baoxin

    2010-01-01

    Purpose Although the naturally occurring antioxidant mangiferin has been widely used, it is not yet known whether it can cross the blood-retina barrier (BRB) and enter the eye. The purpose of this experiment was to investigate the ability of mangiferin to pass the blood-retina barrier. Methods Sprague–Dawley rats were used for biologic fluid sampling after intravenous administration of mangiferin at doses of 10, 25, and 50 mg/kg. Blood and retina samples were collected at different time points post-dose. High-performance liquid chromatography (HPLC) separation was conducted on a COSMOSIL 5C18—MS—II column (4.6 mm×250 mm, 5 μm) with a flow rate of 1.0 ml/min using a mobile phase comprised of methanol −2% glacial acetic acid (40:60 v:v). Results The HPLC method has proven suitable to determine the presence of mangiferin in the eye. The plasma concentration of mangiferin was dose dependent. Pharmacokinetic parameters of mangiferin in plasma after intravenous administration were fitted to the two-compartment model with the first-order elimination and first-order transfer between central and peripheral compartments. The concentration of mangiferin in the retina goes with that in the blood. Mangiferin concentrations in the retina reached 5.69±1.48 μg/ml 0.5 h after intravenous administration (50 mg/kg) and then dropped gradually to 0.30±0.02 μg/ml 5.0 h later. The eye–to-plasma concentration ratio was 2.80%. Conclusions Mangiferin can pass the blood-retina barrier after a single intravenous administration and may be a potential natural antioxidant in treating eye diseases. PMID:20806037

  14. DNA-based diagnosis of isolated sulfite oxidase deficiency by denaturing high-performance liquid chromatography.

    Science.gov (United States)

    Lam, Ching-Wan; Li, Chi-Keung; Lai, Chi-Kong; Tong, Sui-Fan; Chan, Kwok-Yin; Ng, Grace Sui-Fun; Yuen, Yuet-Ping; Cheng, Anna Wai-Fun; Chan, Yan-Wo

    2002-01-01

    Isolated sulfite oxidase deficiency is a rare autosomal recessive disease, characterized by severe neurological abnormalities, seizures, mental retardation, and dislocation of the ocular lenses, that often leads to death in infancy. There is a special demand for prenatal diagnosis, since no effective treatment is available for isolated sulfite oxidase deficiency. Until now, the cDNA sequence of the sulfite oxidase (SUOX) gene has been available, but the genomic sequence of the SUOX gene has not been published. In this study, we have performed a DNA-based diagnosis of isolated sulfite oxidase deficiency in a Chinese patient. To do so, we designed oligonucleotide primers for amplification of the predicted exons and intron-exon boundaries of the SUOX gene obtained from the completed draft version of the human genome. Using overlapping PCR products, we confirmed the flanking intronic sequences of the coding exons and that the entire 466-residue mature peptide is encoded by the last exon of the gene. We then performed mutation detection using denaturing high-performance liquid chromatography (DHPLC). The DHPLC chromatogram of exon 2b showed the presence of heteroduplex peaks only after mixing of the mutant DNA with the wild-type DNA, indicating the presence of a homozygous mutation. Direct DNA sequencing showed a homozygous base substitution at codon 160, changing the codon from CGG to CAG, which changes the amino acid from arginine to glutamine, i.e., R160Q. The DNA-based diagnosis of isolated sulfite oxidase deficiency will enable us to make an accurate determination of carrier status and to perform prenatal diagnosis of this disease. The availability of the genomic sequences of human genes from the completed draft human genome sequence will simplify the development of molecular genetic diagnoses of human diseases from peripheral blood DNA.

  15. Analysis of Some Pesticide Residues in Cauliflower by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Sheheli Islam

    2009-01-01

    Full Text Available Problem statement: Increased use of chemicals on vegetables started gaining momentum and continued its up-trend in Bangladesh. Wide spread use of pesticides in agriculture concern of residue accumulation, which may remain in food and agricultural environment causing concern of human health and risking ecological balance. Attempt made to ensure that their applications were correct and safe and result in no residues in food beyond codex developed maximum residue limits. Approach: This study reported a method based on High Performance Liquid Chromatography (HPLC for determination of pesticide residues used in Cauliflower. Cauliflower sprayed with, 4 different pesticides (diazinon, malathion, chlorpyrifos and cypermethrin at recommended dose and double of recommended dose were analyzed for their residual contents. Samples were collected at same day after application of pesticide. Commercial samples of cauliflowers were collected from different markets of Dhaka city. Reversed-phase HPLC system with UV detection was used for the separation, identification and quantification of all these analytes using acetonitrile-water (70:30, v/v as mobile phase. Results: Limit of detection of 0.02 mg kg-1 was obtained. Calibration curves that constructed for the analytes spiked into samples followed linear relationships with good correlation coefficients (R2>0.990. In the analysis, from vegetables treated with diazinon and chlorpyrifos at recommended and double of recommended doses, residual amounts above respective MRL values were found. Conclusion: Method used permitted the determination of these pesticides in cauliflower at concentration level demanded by current legislation. Attention paid on excess use or abuse of pesticides by judicious application for safety of public health in Bangladesh. Additional data to monitor residues in food and to fill gaps in current knowledge would be helpful in assessing human exposure risks from ingestion of contaminated

  16. Simultaneous determination of cyclodol and diprazin by thin layer chromatography and high performance liquid chromatography.

    Science.gov (United States)

    Makharadze, R; Adeishvili, L; Chelidze, T; Imnadze, N; Nizharadze, N

    2009-11-01

    Ciklodol (trihexyphenidil)--the central and peripheral m-cholinoblocker is currently used with other antipsychotic drugs such as phenotiazines and tricycle antidepressants. For the purpose of simultaneous determination of ciklodol and diprazine, were selected two methods of analysis: Thin Layer Chromatography (TLC) and High Performance Liquid Chromatography (HPLC). During development of TLC method was studied the 10 visualizing system and 24 mobile systems. For individual or simultaneous determination of ciklodol and diprazine were recommended the following solvents' systems: 1. Toluene-acetone-ethanole-25%NH(4)OH (45:45: 7.5:2.5), 2. Hexane-ethyl acetate (15:5), 3. Chloroform-heptene-25%NH(4)OH (16:3:3), 4. Ethylacetate-hexane (10:10), 5. Acetonitrile-metanol (10:10) and 6.Heptene-chloroform-ethanol-25% NH(4)OH (5:10:3:1). As visualizing systems were chosen: Iodine vapors, blacklight (UV254) and reagent of FNP. Reagent of FNP gives colored spot just with diprazine and it is also could be used for separation of both objects in simultaneous analysis. Developed HPLC method of simultaneous determination of ciklodol and diprazine: like mobile phase is recommended: Acetonitril- 0.05M KH(2)PO4 (55:45) (v/v) +H(3)PO(4) (pH3.5), column EC250 x 4.6mm, with solid phase Nucleosil, flow rate 1ml/min, sample volume 40 microl. In given conditions, the retention time of ciklodol is 6.005min and diprazine 7.227min. Developed method of simultaneous determination and separation of ciklodol and diprazine in respective mixtures could be successfully applied as in the pharmaceutical, as well in the chemical-toxicological laboratories.

  17. Ambient temperature nanoelectrospray ion mobility detector for high performance liquid chromatography in determining amines.

    Science.gov (United States)

    Chen, Chuang; Hou, Keyong; Wang, Weiguo; Li, Jinghua; Li, Haiyang

    2014-09-01

    A nanoelectrospray ionization ion mobility spectrometer (nanoESI-IMS) working at ambient pressure and ambient temperature was developed as a detector of high performance liquid chromatography (HPLC) to achieve sensitive detection of amines with no derivatization and meanwhile provide another dimension of separation. The easier desolvation property of the charged droplets formed in nanoESI source enabled complete desolvation of the product ions of sixteen amines and drugs using the nanoESI-IMS at ambient temperature. Working at ambient temperature was good for suppressing the dissociation of thermal volatile ions, such as only the proton adducted molecular ions were observed for morphine in the nanoESI-IMS. Besides, the resolving power of the nanoESI-IMS also showed an increasing tendency as lowering the working temperature, an increment of 19 percent and 10 percent was observed for diethylamine and triethylamine as the temperature dropped from 92°C to 32°C. The resolving power of the nanoESI-IMS at 32°C for the 16 tested compounds was amid 33-44. With the nanoESI-IMS coupled to HPLC, a six-compound mixture including isomers was successfully separated and detected without any derivatization. And linear response ranges of 1 to 20, 0.5 to 20, and 0.8 to 20μgml(-1) and limits of detection of 0.25, 0.15, and 0.17μgml(-1) for triethylamine, diethylamine, and butylamine, respectively, were obtained with the hyphenated system. These results showed the excellent performance of the two-dimensional separation and detection method in direct qualitative and quantitative analyses of amines.

  18. Advanced use of high-performance liquid chromatography for synthesis of controlled metal clusters.

    Science.gov (United States)

    Niihori, Yoshiki; Matsuzaki, Miku; Uchida, Chihiro; Negishi, Yuichi

    2014-07-21

    Because the synthesis of metal clusters with multiple ligand types results in a distribution of ligands, high-resolution separation of each unique cluster from the mixture is required for precise control of the ligand composition. Reverse-phase high-performance liquid chromatography combined with appropriate transitioning of the mobile phase composition is an extremely effective means of separating ligand combinations when working with metal clusters protected by two different types of thiolates. We report herein advanced use of this method. The studies involving Au₂₄Pd(SR₁)₁₈-x(SR₂)x and Au₂₄Pd(SR₁)₁₈-x(SeR₂)x (SR₁, SR₂ = thiolate, SeR₂ = selenolate) revealed the following. (1) In general, an increase in the difference between the polarities of the functional groups incorporated in the two types of ligands improves the separation resolution. A suitable ligand combination for separation can be predicted from the retention times of Au₂₄Pd(SR₁)₁₈ and Au₂₄Pd(SR₂)₁₈, which cause the terminal peaks in a series of peaks. (2) The use of a step-gradient program during the mobile phase substitution results in improved resolution compared to that achievable with the linear gradients applied in prior work. (3) This technique is also useful for the evaluation of the chemical compositions of metal clusters protected by two different types of ligands with similar molecular weights. These findings will provide clear design guidelines for the functionalization of metal clusters via control of the ligand composition, and will also improve our understanding of the high-resolution isolation of metal clusters.

  19. Quantification of free formaldehyde in carrageenan and processed Eucheuma seaweed using high-performance liquid chromatography.

    Science.gov (United States)

    Hornshøj, Bettina Høj; Kobbelgaard, Sara; Blakemore, William R; Stapelfeldt, Henrik; Bixler, Harris J; Klinger, Markus

    2015-01-01

    In 2010 the European Commission placed a limit on the amount of free formaldehyde in carrageenan and processed Eucheuma seaweed (PES) of 5 mg kg(-1). Formaldehyde is not used in carrageenan and PES processing and accordingly one would not expect free formaldehyde to be present in carrageenan and PES. However, surprisingly high levels up to 10 mg kg(-1) have been found using the generally accepted AOAC and Hach tests. These findings are, per proposed reaction pathways, likely due to the formation of formaldehyde when sulphated galactose, the backbone of carrageenan, is hydrolysed with the strong acid used in these conventional tests. In order to minimise the risk of false-positives, which may lead to regulatory non-compliance, a new high-performance liquid chromatography (HPLC) method has been developed. Initially, carrageenan or PES is extracted with 2-propanol and subsequently reacted with 2,4-dinitrophenylhydrazine (DNPH) to form the chromophore formaldehyde-DNPH, which is finally quantified by reversed-phase HPLC with ultraviolet light detection at 355 nm. This method has been found to have a limit of detection of 0.05 mg kg(-1) and a limit of quantification of 0.2 mg kg(-1). Recoveries from samples spiked with known quantities of formaldehyde were 95-107%. Using this more specific technique, 20 samples of carrageenan and PES were tested for formaldehyde. Only one sample had a detectable content of formaldehyde (0.40 mg kg(-1)), thus demonstrating that the formaldehyde content of commercial carrageenan and PES products are well below the European Commission maximum limit of 5 mg kg(-1).

  20. Robust naphthyl methacrylate monolithic column for high performance liquid chromatography of a wide range of solutes.

    Science.gov (United States)

    Jonnada, Murthy; El Rassi, Ziad

    2015-08-28

    An organic monolithic column based on the co-polymerization of 2-naphthyl methacrylate (NAPM) as the functional monomer and trimethylolpropane trimethacrylate (TRIM) as the crosslinker was introduced for high performance reversed-phase liquid chromatography (RPC). The co-polymerization was performed in situ in a stainless steel column of 4.6mm i.d. in the presence of a ternary porogen consisting of 1-dodecanol and cyclohexanol. This monolithic column (referred to as naphthyl methacrylate monolithic column or NMM column) showed high mechanical stability at relatively high mobile phase flow velocity indicating that the column has excellent hydrodynamic characteristics. To characterize the NMM column, different probe molecules including alkyl benzenes, and aniline, benzene, toluene and phenol derivatives were chromatographed on the column and the results in terms of k, selectivity and plate counts were compared to those obtained on an octadecyl silica (ODS) column in order to assess the presence of π-π and hydrophobic interactions on the NMM column under otherwise the same elution conditions. The NMM column offered additional π-π interactions with aromatic molecules in addition to hydrophobic interactions under RPC elution conditions. Run-to-run and column-to-column reproducibility of solute k values were evaluated, and percent relative standard deviation of column using shallow (30min at 1.0mL/min), steep (10min at 1.0mL/min) and ultra steep (1min at 3.0mL/min) linear gradient elution at increasing ACN concentration in the mobile phase using a 10cm×4.6mm i.d. column in case of shallow and steep linear gradients and a 3cm×4.6mm i.d. column for ultra steep linear gradient.

  1. [Rapid determination of propranolol enantiomers in rat plasma by column-switching-high performance liquid chromatography].

    Science.gov (United States)

    Wu, Xiaoyu; Wang, Rong; Xie, Hua; Wang, Jianfeng; Jia, Zhengping; Zhang, Qiang; Wang, Xianhua

    2011-12-01

    A high performance liquid chromatographic (HPLC) method with column-switching was developed and validated for rapid determination of two propranolol enantiomers in rat plasma. The column of restricted-access media was used as a pre-treatment column and a Chiralcel OD-RH was used as analytical column. The plasma samples were injected directly into the pretreatment column to remove plasma protein and endogenous constituents as well as to retent the propranolol enantiomers in the column using the mobile phase of borate buffer (pH 8.5)-methanol (95:5, v/v) at the flow rate of 1.0 mL/min. Then the propranolol enantiomers were transferred to the Chiralcel OD-RH column using the mobile phase of isopropanol-ethanol-0.2 mmol/L borate buffer (pH 8.5) (30: 30: 40, v/v/v) at a flow rate of 0.8 mL/min by column-switching technology. The column-switching time was 3.0 min, the used wavelength was 293 nm and the column temperature was set at 25 degrees C. The calibration curve showed excellent linear relationship (r = 0.999 5) in the concentration range from 25 mg/L to 500 mg/L for propranolol enantiomers in plasma. The intra-day and inter-day assay precisions and accuracies were well and the relative standard deviations (RSDs) were less than 5%. The average recoveries (n = 6) of the two enantiomers at 3 spiked levels were from 97.89% to 101.56%. All the values of the method validation were within the generally accepted criteria for biological sample analysis. The results show that the method is convenient, quick, sensitive and accurate. The method was successfully applied in the determination of propranolol enantiomers in rat blood pharmacokinetics study.

  2. Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns.

    Science.gov (United States)

    Jones, Andrew; Pravadali-Cekic, Sercan; Hua, Stanley; Kocic, Danijela; Camenzuli, Michelle; Dennis, Gary; Shalliker, Andrew

    2016-04-26

    A protocol for the use of reaction flow high performance liquid chromatography columns for methods employing post column derivatization (PCD) is presented. A major difficulty in adapting PCD to modern HPLC systems and columns is the need for large volume reaction coils that enable reagent mixing and then the derivatization reaction to take place. This large post column dead volume leads to band broadening, which results in a loss of observed separation efficiency and indeed detection in sensitivity. In reaction flow post column derivatization (RF-PCD) the derivatization reagent(s) are pumped against the flow of mobile phase into either one or two of the outer ports of the reaction flow column where it is mixed with column effluent inside a frit housed within the column end fitting. This technique allows for more efficient mixing of the column effluent and derivatization reagent(s) meaning that the volume of the reaction loops can be minimized or even eliminated altogether. It has been found that RF-PCD methods perform better than conventional PCD methods in terms of observed separation efficiency and signal to noise ratio. A further advantage of RF-PCD techniques is the ability to monitor effluent coming from the central port in its underivatized state. RF-PCD has currently been trialed on a relatively small range of post column reactions, however, there is currently no reason to suggest that RF-PCD could not be adapted to any existing one or two component (as long as both reagents are added at the same time) post column derivatization reaction.

  3. Rayleigh light scattering detection of three α1-adrenoceptor antagonists coupled with high performance liquid chromatograph

    Science.gov (United States)

    Li, Ai Ping; Peng, Huanjun; Peng, Jing Dong; Zhou, Ming Qiong; Zhang, Jing

    2015-08-01

    Herein, a Rayleigh light-scattering (RLS) detection method combined with high performance liquid chromatograph (HPLC) without any post-column probe was developed for the separation and determination of three α1-adrenoceptor antagonists. The quantitative analysis is benefiting from RLS signal enhancement upon addition of methanol which induced molecular aggregation to form an hydrophobic interface between aggregates and water that produce a sort of superficial enhanced scattering effect. A good chromatographic separation among the compounds was achieved using a Gemini 5u C18 reversed phase column (250 mm × 4.6 mm; 4 μm) with a mobile phase consisting of methanol and ammonium acetate-formic acid buffer solution (25 mM; pH = 3.0) at the flow rate of 0.7 mL min-1. The RLS signal was monitored at λex = λem = 354 nm. A limit of detection (LOD) of 0.065-0.70 μg L-1 was reached and a linear range was found between peak height and concentration in the range of 0.75-15 μg L-1 for doxazosin mesylate (DOX), 0.075-3.0 μg L-1 for prazosin hydrochloride (PRH), and 0.25-5 μg L-1 for terazosin hydrochloride (TEH), with linear regression coefficients all above 0.999. Recoveries from spiked urine samples were 88.4-99.0% which is within acceptable limits. The proposed method is convenient, reliable and sensitive which has been used successfully in human urine samples.

  4. [Determination of aflatoxins in cashew by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Bi, Ruifeng; Fan, Zhixian; Fu, Meng

    2011-12-01

    A method for the determination of four aflatoxins in cashew using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed. The sample was extracted with methanol-water (8: 2, v/v) solution, followed by a cleanup procedure with Florisil column. The target compounds were eluted using 5 mL acetone-water-formic acid (96: 3.5:0.5, v/v/v) solution. The eluate was dried under N2, then dissolved in 1 mL methanol. Four aflatoxins were separated in MG C18 column (100 mm x 3.0 mm, 3 microm) adopting a gradient program within 15 min. A triple quadrupole mass spectrometry equipped with an electrospray ionization source operated in the positive ion mode was used to detect the aflatoxins. The good correlation coefficients (r2 > 0.997) of the four aflatoxins were obtained within their respective linear ranges. The limits of detection (S/N = 3) were between 0.009 microg/kg and 0.04 microg/kg, and the limits of quantification (S/N = 10) were between 0.03 microg/kg and 0.12 microg/kg. The recoveries were in a range of 63.0% -78.5% with the relative standard deviations (RSDs) varied from 2.8% to 9.1%. The validation results meet the requirements of trace assay. Matrix effects were estimated and the signal suppression/enhancement ranged from 88.8% to 99.4%. The results indicate that the developed method is simple, fast, accurate, and can be applied for the determination of fours aflatoxins in cashew.

  5. Chiral stationary phases based on chitosan bis(methylphenylcarbamate)-(isobutyrylamide) for high-performance liquid chromatography.

    Science.gov (United States)

    Tang, Sheng; Bin, Qin; Chen, Wei; Bai, Zheng-Wu; Huang, Shao-Hua

    2016-04-01

    A series of chitosan bis(methylphenylcarbamate)-(isobutyrylamide) derivatives were synthesized by carbamylating chitosan isobutyrylamide with different methylphenyl isocyanates. Then the prepared chitosan derivatives were coated onto 3-aminopropyl silica particles, resulting in a series of new chiral stationary phases (CSPs) for high-performance liquid chromatography. It was observed that the chiral recognition abilities of these coated-type CSPs depended very much on the substituents on the phenyl moieties of the chitosan derivatives, the eluent composition, as well as the structure of racemates. As a typical example, the eluent tolerance of the prepared CSP with the best enantioseparation ability was investigated in detail, and the results revealed that the CSP exhibited extraordinary solvent tolerance and could still work without significant loss in enantioseparation capability after being flushed with chloroform (100%), ethyl acetate (100%) and even THF/n-hexane (70/30, v/v), while the traditional coated-type CSPs based on the cellulose and amylose derivatives, such as cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC) and amylose tris(3,5-dimethylphenylcarbamate) (ADMPC), might be dissolved or highly swollen in these eluents. Therefore, the application of the resultant CSPs could address the problem of the dissolution and high swelling of traditional coated-type CSPs in some unusual eluents, broadening the possibility of eluent choice. In addition, a comparison of the prepared CSPs with the well known CDMPC- and ADMPC- based CSPs concerning the chiral recognition ability was also made. Separation performances achieved on the as-prepared CSPs in different eluents were found to be even superior to CDMPC- and ADMPC-based CSPs for the tested chiral compounds. In summary, we could safely draw the conclusion that the CSPs derived from chitosan isobutyrylamide derivatives were capable of excellent chiral recognition ability, and meanwhile possessed satisfactory

  6. Enantiomeric Separations of Pyriproxyfen and its Six Chiral Metabolites by High-Performance Liquid Chromatography.

    Science.gov (United States)

    Zhang, Chuntao; Liu, Hui; Liu, Donghui; Wang, Liying; Gao, Jing; Zhou, Zhiqiang; Wang, Peng

    2016-03-01

    Pyriproxyfen is a chiral insecticide, and over 10 metabolites have been identified in the environment. In this work the separations of the enantiomers of pyriproxyfen and its six chiral metabolites were studied by high-performance liquid chromatography (HPLC). Both normal phase and reverse phase were applied using the chiral columns Chiralpak IA, Chiralpak IB, Chiralpak IC, Chiralcel OD, Chiralcel OD-RH, Chiralpak AY-H, Chiralpak AD-H, Chiracel OJ-H, (R,R)-Whelk-O 1, and Lux Cellulose-3. The effects of the chromatographic parameters such as mobile phase composition and temperature on the separations were investigated and the enantiomers were identified with an optical rotation detector. The enantiomers of these targets could obtain complete separations (resolution factor Rs > 1.5) on Chiralpak IA, Chiralpak IB, Chiralcel OD, Chiralpak AY-H, or Chiracel OJ-H under normal conditions. Chiralcel OJ-H showed the best chiral separation results with n-hexane as mobile phase and isopropanol (IPA) as modifier. The simultaneous enantiomeric separation of pyriproxyfen and four chiral metabolites was achieved on Chiralcel OJ-H under optimized condition: n-hexane/isopropanol = 80/20, 15°C, flow rate of 0.8 ml/min, and UV detection at 230 nm. The enantiomers of pyriproxyfen and the metabolites , , and obtained complete separations on Chiralpak IA, Chiralpak IC, and Lux Cellulose-3 under reverse phase using acetonitrile/water as the mobile phase. The retention factors (k) and selectivity factors (α) decreased with increasing temperature, and the separations were better under low temperature in most cases. The work is of significance for the investigation of the environmental behaviors of pyriproxyfen on an enantiomeric level.

  7. Pharmacokinetics of mitomycin C in dogs: application of a high-performance liquid chromatographic assay.

    Science.gov (United States)

    Barbhaiya, R H; Papp, E A; Van Harken, D R; Smyth, R D

    1984-09-01

    A normal-phase high-performance liquid chromatographic (HPLC) assay was developed for the determination of mitomycin C in plasma and urine. The method involves extraction of mitomycin C from plasma or urine into ethyl acetate-2-propanol-chloroform (70:15:15) with UV detection at 365 nm. Quantitation was performed with an internal standard (porfiromycin) by the peak height ratio method. Excellent correlation was obtained between the HPLC assay and the established microbiological cup-plate bioassay. The pharmacokinetics of mitomycin C were investigated in beagle dogs following a 1-mg/kg iv (22-mg/m2) bolus dose. The plasma mitomycin C concentration versus time data were analyzed by using an open three-compartment model. The average volume of distribution was 1.90 L or 17% of body weight for the central compartment and 7.7 L or 68% of body weight for the terminal elimination phase. The volumes of distribution at steady state, calculated by model-dependent and -independent methods, compared very well with each other and were 6.5 L or 58% of body weight. Total body clearance averaged 112 mL/min, and the mean terminal plasma half-life was 53 min. The 0-24-h urinary excretion of intact mitomycin C accounted for 19% of the dose. The terminal half-life and percent urinary recovery of mitomycin C in dogs is similar to that in humans. Based on these observations, the dog appears to be a good model for studying the disposition of mitomycin C.

  8. [Determination of phospholipids in bear bile by isocratic high performance liquid chromatography].

    Science.gov (United States)

    Lu, X Q; Wang, Z H; Hong, X K; Sun, J J; Zhang, S W

    1999-11-01

    A high performance liquid chromatographic method for the determination of phosphatidylcholine (PC), phosphatidylethanolamine (PE) and phosphatidylinositol (PI) in the bear bile was established. The air-dried bile of bear was ground into powder and extracted continuously with V(chloroform):V(methanol) = 1:1 to a final dilution 25-fold the volume of the sample. The extract was washed by addition to it of 0.5 its volume of 0.58% aqueous NaCl. The resulting mixture separated into two phases. The lower phase was the total pure lipid extract and was diluted to the desired volume by addition of V(chloroform):V(methanol) = 1:1 mixture and then injected into the HPLC system. The conditions of HPLC were P-E silica column (150 mm x 4.6 mm i.d., 10 microns); V(acetonitrile):V(methanol) = 76:24 mobile phase with a flow rate of 1.5 mL/min and UV detector at 205 nm. The linear regression equation was Y = 5,917X + 1,709(r = 0.9970) for PI, Y = 7,362.1X-6,608.2(r = 0.9949) for PE and Y = 2,457X-2,460.5(r = 0.9972) for PC. The linear range were 1.0-12.0 micrograms, 2.0-24.0 micrograms and 9.5-114.0 micrograms respectively, The relative standard deviation of peaks were 1.6%, 0.89% and 2.6% respectively. The average recovery of PC was 89.30% (RSD = 2.0%). The method enables a simple, rapid and reproducible quantification of PI, PE and PC.

  9. Determination of plasma lactic acid concentration and specific activity using high-performance liquid chromatography.

    Science.gov (United States)

    Bleiberg, B; Steinberg, J J; Katz, S D; Wexler, J; LeJemtel, T

    1991-08-23

    Assessment of lactate metabolism is of particular interest during exercise and in disease states such as diabetes, shock, and absorptive abnormalities of short-chain fatty acids by the colon. We describe an analytical method that introduces radio-active tracers and high-performance liquid chromatography (HPLC) to simultaneously analyze concentrations and specific activities (SAs) of plasma lactate. The HPLC conditions included separation on a reversed-phase column (octadecylsilane) and an isocratic buffer (30% acetonitrile in water). [3H]Acetate served as an internal standard. Lactate and acetate were extracted from plasma samples with diethyl ether following a pH adjustment to less than 1.0 and back-extracted into a hydrophilic phase with sodium carbonate (2 mM, pH greater than 10.0). Lactate is detected in the ultraviolet range (242 and 320 nm) by derivatization with alpha-bromoacetophenone. Control plasma samples were studied after an overnight fast for precision and analytical recovery. Calibration curves were linear in the range 0.18-6.0 mM (r = 0.92). The precision was 3% and the analytical recovery was 87%. The detection limit of the method was 36 pmol. Determination of lactate metabolism was performed in a patient with chronic congestive heart failure who was administered primed-continuous L-[U-14C]lactate (10 microCi bolus and 0.3 microCi/min continuously) during a 60-min rest period. Mean arterial lactate concentration and SA were 1.69 +/- 0.2 mM and 253.8 +/- 22 dpm/mumol, respectively. Systemic lactate turnover was 25.65 mumol/kg per min. Lactic acid systemic turnover, organ uptake and release rates can be accurately determined by isocratic HPLC.

  10. Simultaneous determination of multiple marker constituents in concentrated Gegen Tang granule by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Yip Yuekeung

    2007-06-01

    Full Text Available Abstract Background Concentrated Gegen Tang (GT granule is a widely available traditional Chinese medicinal product for the treatment of cold and flu. There was no reliable analytical method available for the quality assessment of GT granules. Methods An HPLC method with an Agilent Zorbax SB-Phenyl Stablebond column (250 × 4.6 mm, 5 μm was developed and validated. The mobile phase gradient was a mixture of 0.1% trifluoroacetic acid (TFA in acetonitrile (ACN and 0.1% TFA in water. The detection with a diode-array detector was set at 207, 230, 250 and 275 nm. Seven components, namely puerarin, daidzein, paeoniflorin, cinnamic acid, glycyrrhizin, ephedrine and pseudoephedrine were selected as marker compounds for the evaluation. Results The regression equations revealed good linear relationships (correlation coefficients: 0.9994–0.9998 between the peak areas and concentrations. The recovery was between 98.8% and 101.7% with good precision and accuracy. The quality of GT granule from four different manufacturers was evaluated with this newly developed method. Samples from four manufacturers showed similar profiles but contents of the detected markers varied significantly among manufacturers and batches. Conclusion A new method using high performance liquid chromatography (HPLC has been developed for simple and reliable quality control of commercial concentrated GT granules. Sensitivity was increased by multi-wavelength detection. The contents of selected marker components in GT granules varied significantly among manufacturers and batches, making it necessary to evaluate the quality of concentrated GT granules in the market.

  11. Simultaneous determination of three sesquiterpene lactones in Aucklandia lappa Decne by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Chang-Seob Seo

    2015-01-01

    Full Text Available Background: Aucklandia lappa Decne, a well known traditional herbal medicine, is used for the treatment of asthma, rheumatism, coughs, tuberculosis, and many other diseases. Objective: We performed simultaneous analysis of three sesquiterpene lactones, costunolide (1, dehydrocostus lactone (2, and alantolactone (3, obtained from a 70% methanol extract of A. lappa using high performance liquid chromatography–photodiode array (HPLC–PDA techniques. Materials and Methods: The compounds 1–3 were separated using a reversed phase SunFire™ C18 analytical column kept at 35°C by the isocratic elution with distilled water and acetonitrile as mobile phase. The flow rate was 1.0 mL/min, and the injection volume was 10 μL. Results: The established analytical method showed high linearity, with a correlation coefficient ≥0.9999. The limit of detection and the limit of quantification of compounds 1–3 were 0.06–0.13 μg/mL and 0.21–0.42 μg/mL, respectively. The recovery of the compounds 1–3 was 97.27–103.00%. The intra and inter day relative standard deviations were 0.09–0.97% and 0.09–1.06%, respectively. The amounts of the compounds 1–3 were 17.32, 28.26, and 0.01 mg/g, respectively. Conclusion: The established and validated HPLC–PDA method may be help for the quality control of herbal medicine, A. lappa.

  12. High performance liquid chromatography--atomic fluorescence spectrometric determination of arsenic species in beer samples

    Energy Technology Data Exchange (ETDEWEB)

    Melo Coelho, N.M.; Parrilla, Carmen; Cervera, M.L.; Pastor, A.; Guardia, M. de la

    2003-04-10

    A method has been developed for the direct determination of As(III), dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and As(V) in beers by hydride generation--atomic fluorescence spectrometry after separation of arsenic species by high performance liquid chromatography. Compounds were separated by anion-exchange chromatography with isocratic elution using KH{sub 2}PO{sub 4}/K{sub 2}HPO{sub 4} as mobile phase with elution times of 1.67, 2.08, 6.52 and 10.72 min for As(III), DMA, MMA and As(V), respectively. Parameters affecting the hydride generation of all arsenic species were studied and the best conditions were established as a reaction coil of 150 cm, for a sample injected volume of 100 {mu}l, a 4.0% (m/v) solution of sodium tetrahydroborate and 2.0 mol l{sup -1} hydrochloric acid with flow rates of 2.7 and 1.7 ml min{sup -1}, respectively and a flow rate of 500 ml min{sup -1} for the argon carrier gas. Under the best experimental conditions, the detection limit was found to be 0.12, 0.20, 0.27 and 0.39 {mu}g l{sup -1} for As(III), DMA, MMA and As(V), respectively. The relative standard deviation for eight independent determinations varied from 3.9 till 8.9% for species considered at a concentration level of 10.0 {mu}g l{sup -1}. Recovery and comparative studies evidenced that the method is suitable for the accurate determination of arsenic species in water and beer samples.

  13. Ultra-high-performance liquid chromatography profiling method for chemical screening of proanthocyanidins in Czech hops.

    Science.gov (United States)

    Olšovská, J; Kameník, Z; Čejka, P; Jurková, M; Mikyška, A

    2013-11-15

    Hops represent an important natural source of bioactive polyphenols, particularly proanthocyanidins, which can contribute to prevention of several civilization diseases, owing to their antioxidant and radical scavenging activity. We have developed a high-throughput ultra-high-performance liquid chromatography time-of-flight mass spectrometry profiling method, which can be used for monitoring of bioactive proanthocyanidins in hops. The method was applied for analysis of hops of four Czech varieties (Saaz, Sladek, Preminat and Agnus) from the 2011 crop (9 localities, 11 samples) and the 2012 crop (24 localities, 40 samples). Hop samples were extracted by acetone and the analytes were separated on the Acquity UPLC BEH Shield RP18 column. Partial validation of the method revealed a satisfactory intra-day repeatability of the method for retention times (relative standard deviation within 1.39%) as well as areas under the peaks (within 9.89%). Experimental data were evaluated using principal component analysis and cluster analysis. Significant amounts of di-, tri- and tetramer proanthocyanidins consisting of (epi)catechin and (epi)gallocatechin were found in the hop samples. The dependence of the proantocyanidin composition on both the variety and the growing locality was observed. Specifically, the traditional Saaz variety contained more frequently oligomers formed by (epi)catechin units only, whereas the varieties Premiant and Agnus produced oligomers consisting of (epi)catechin as well as (epi)gallocatechin units. The relative abundance of proanthocyanidins in studied hop varieties from the two crops, 2011 and 2012, did correspond to each other. In the further perspective, the method may also be used for prediction of qualitative marks or authenticity verification of hops.

  14. Dynamic Behavior of Clobazam on High-Performance Liquid Chromatography Chiral Stationary Phases.

    Science.gov (United States)

    Sabia, Rocchina; De Martino, Michela; Cavazzini, Alberto; Villani, Claudio

    2016-01-01

    Clobazam, a 1,5-benzodiazepin-2,4-dione, is a chiral molecule because its ground state conformation features a nonplanar seven-membered ring lacking reflection symmetry elements. The two conformational enantiomers of clobazam interconvert at room temperature by a simple ring-flipping process. Variable temperature HPLC on the Pirkle type (R)-N-(3,5-dinitronenzoyl)phenylglycine and (R,R)-Whelk-O1 chiral stationary phases (CSPs) allowed us to separate for the first time the conformational enantiomers of clobazam and to observe peak coalescence-decoalescence phenomena due to concomitant separation and interconversion processes occurring on the same time scale. Clobazam showed temperature dependent dynamic high-performance liquid chromatography (HPLC) profiles with interconversion plateaus on the two CSPs indicative of on-column enantiomer interconversion. (enantiomerization) in the column temperature range between Tcol = 10°C and Tcol = 30°C, whereas on-column interconversion was absent at temperature close to or lower than Tcol = 5°C. Computer simulation of exchange-deformed HPLC profiles using a program based on the stochastic model yielded the apparent rate constants for the on-column enantiomerization and the corresponding free energy activation barriers. At Tcol = 20°C the averaged enantiomerization barriers, ΔG(‡), for clobazam were found in the range 21.08-21.53 kcal mol(-1) on the two CSPs. The experimental dynamic chromatograms and the corresponding interconversion barriers reported in this article are consistent with the literature data measured by DNMR at higher temperatures and in different solvents.

  15. Validation of stability indicating high performance liquid chromatographic method for estimation of Desloratadine in tablet formulation

    Directory of Open Access Journals (Sweden)

    R.B. Patel

    2017-02-01

    Full Text Available A simple, sensitive and specific stability indicating high performance liquid chromatographic (HPLC method for the estimation of Desloratadine was developed and validated. Desloratadine was separated and quantitated on Inertsil ODS-3 V column (250 mm length, 4.6 mm id, 5 μm particle size using a mixture of methanol–phosphate buffer of pH 7.0 (70:30 v/v as a mobile phase and at a flow rate of 1.0 mL/min. Quantification was achieved with an UV detector at 254 nm over the concentration range of 5–75 μg/mL. The applied HPLC method allowed the separation and quantification of Desloratadine with good linearity (r2 = 0.999 in the studied concentration range. Limit of detection and limit of quantification were found to be 1.28 μg/mL and 3.89 μg/mL, respectively. The method was validated as per the International Conference on Harmonization (ICH guidelines. Desloratadine stock solution was subjected to different stress conditions. The degraded product peaks were well resolved from the pure drug peak with significant difference in their retention time values. Stressed samples were assayed using developed HPLC method. Statistical analysis of the data showed that the method is precise, accurate, reproducible, and selective for the analysis of Desloratadine. The method was successfully applied to the estimation of Desloratadine in tablet dosage form.

  16. Chromatographic behavior of small organic compounds in low-temperature high-performance liquid chromatography using liquid carbon dioxide as the mobile phase.

    Science.gov (United States)

    Motono, Tomohiro; Nagai, Takashi; Kitagawa, Shinya; Ohtani, Hajime

    2015-07-01

    Low-temperature high-performance liquid chromatography, in which a loop injector, column, and detection cell were refrigerated at -35ºC, using liquid carbon dioxide as the mobile phase was developed. Small organic compounds (polyaromatic hydrocarbons, alkylbenzenes, and quinones) were separated by low-temperature high-performance liquid chromatography at temperatures from -35 to -5ºC. The combination of liquid carbon dioxide mobile phase with an octadecyl-silica (C18 ) column provided reversed phase mode separation, and a bare silica-gel column resulted in normal phase mode separation. In both the cases, nonlinear behavior at approximately -15ºC was found in the relationship between the temperature and the retention factors of the analytes (van't Hoff plots). In contrast to general trends in high-performance liquid chromatography, the decrease in temperature enhanced the separation efficiency of both the columns.

  17. Incorporation of ionic liquid into porous polymer monoliths to enhance the separation of small molecules in reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Wang, Jiafei; Bai, Ligai; Wei, Zhen; Qin, Junxiao; Ma, Yamin; Liu, Haiyan

    2015-06-01

    An ionic liquid was incorporated into the porous polymer monoliths to afford stationary phases with enhanced chromatographic performance for small molecules in reversed-phase high-performance liquid chromatography. The effect of the ionic liquid in the polymerization mixture on the performance of the monoliths was studied in detail. While monoliths without ionic liquid exhibited poor resolution and low efficiency, the addition of ionic liquid to the polymerization mixture provides highly increased resolution and high efficiency. The chromatographic performances of the monoliths were demonstrated by the separations of various small molecules including aromatic hydrocarbons, isomers, and homologues using a binary polar mobile phase. The present column efficiency reached 27 000 plates/m, which showed that the ionic liquid monoliths are alternative stationary phases in the separation of small molecules by high-performance liquid chromatography.

  18. Comparison of ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography for the separation of spirostanol saponins.

    Science.gov (United States)

    Zhu, Ling-Ling; Zhao, Yang; Xu, Yong-Wei; Sun, Qing-Long; Sun, Xin-Guang; Kang, Li-Ping; Yan, Ren-Yi; Zhang, Jie; Liu, Chao; Ma, Bai-Ping

    2016-02-20

    Spirostanol saponins are important active components of some herb medicines, and their isolation and purification are crucial for the research and development of traditional Chinese medicines. We aimed to compare the separation of spirostanol saponins by ultra-high performance supercritical fluid chromatography (UHPSFC) and ultra-high performance liquid chromatography (UHPLC). Four groups of spirostanol saponins were separated respectively by UHPSFC and UHPLC. After optimization, UHPSFC was performed with a HSS C18 SB column or a Diol column and with methanol as the co-solvent. A BEH C18 column and mobile phase containing water (with 0.1% formic acid) and acetonitrile were used in UHPLC. We found that UHPSFC could be performed automatically and quickly. It is effective in separating the spirostanol saponins which share the same aglycone and vary in sugar chains, and is very sensitive to the number and the position of hydroxyl groups in aglycones. However, the resolution of spirostanol saponins with different aglycones and the same sugar moiety by UHPSFC was not ideal and could be resolved by UHPLC instead. UHPLC is good at differentiating the variation in aglycones, and is influenced by double bonds in aglycones. Therefore, UHPLC and UHPSFC are complementary in separating spirostanol saponins. Considering the naturally produced spirostanol saponins in herb medicines are different both in aglycones and in sugar chains, a better separation can be achieved by combination of UHPLC and UHPSFC. UHPSFC is a powerful technique for improving the resolution when UHPLC cannot resolve a mixture of spirostanol saponins and vice versa.

  19. Development and validation of high-performance liquid chromatography and high-performance thin-layer chromatography methods for the quantification of khellin in Ammi visnaga seed.

    Science.gov (United States)

    Kamal, Abid; Khan, Washim; Ahmad, Sayeed; Ahmad, F J; Saleem, Kishwar

    2015-01-01

    The present study was used to design simple, accurate and sensitive reversed phase-high-performance liquid chromatography RP-HPLC and high-performance thin-layer chromatography (HPTLC) methods for the development of quantification of khellin present in the seeds of Ammi visnaga. RP-HPLC analysis was performed on a C18 column with methanol: Water (75: 25, v/v) as a mobile phase. The HPTLC method involved densitometric evaluation of khellin after resolving it on silica gel plate using ethyl acetate: Toluene: Formic acid (5.5:4.0:0.5, v/v/v) as a mobile phase. The developed HPLC and HPTLC methods were validated for precision (interday, intraday and intersystem), robustness and accuracy, limit of detection and limit of quantification. The relationship between the concentration of standard solutions and the peak response was linear in both HPLC and HPTLC methods with the concentration range of 10-80 μg/mL in HPLC and 25-1,000 ng/spot in HPTLC for khellin. The % relative standard deviation values for method precision was found to be 0.63-1.97%, 0.62-2.05% in HPLC and HPTLC for khellin respectively. Accuracy of the method was checked by recovery studies conducted at three different concentration levels and the average percentage recovery was found to be 100.53% in HPLC and 100.08% in HPTLC for khellin. The developed HPLC and HPTLC methods for the quantification of khellin were found simple, precise, specific, sensitive and accurate which can be used for routine analysis and quality control of A. visnaga and several formulations containing it as an ingredient.

  20. Development and validation of high-performance liquid chromatography and high-performance thin-layer chromatography methods for the quantification of khellin in Ammi visnaga seed

    Directory of Open Access Journals (Sweden)

    Abid Kamal

    2015-01-01

    Full Text Available Objective: The present study was used to design simple, accurate and sensitive reversed phase-high-performance liquid chromatography RP-HPLC and high-performance thin-layer chromatography (HPTLC methods for the development of quantification of khellin present in the seeds of Ammi visnaga. Materials and Methods: RP-HPLC analysis was performed on a C18 column with methanol: Water (75: 25, v/v as a mobile phase. The HPTLC method involved densitometric evaluation of khellin after resolving it on silica gel plate using ethyl acetate: Toluene: Formic acid (5.5:4.0:0.5, v/v/v as a mobile phase. Results: The developed HPLC and HPTLC methods were validated for precision (interday, intraday and intersystem, robustness and accuracy, limit of detection and limit of quantification. The relationship between the concentration of standard solutions and the peak response was linear in both HPLC and HPTLC methods with the concentration range of 10–80 μg/mL in HPLC and 25–1,000 ng/spot in HPTLC for khellin. The % relative standard deviation values for method precision was found to be 0.63–1.97%, 0.62–2.05% in HPLC and HPTLC for khellin respectively. Accuracy of the method was checked by recovery studies conducted at three different concentration levels and the average percentage recovery was found to be 100.53% in HPLC and 100.08% in HPTLC for khellin. Conclusions: The developed HPLC and HPTLC methods for the quantification of khellin were found simple, precise, specific, sensitive and accurate which can be used for routine analysis and quality control of A. visnaga and several formulations containing it as an ingredient.

  1. High-performance liquid chromatographic assay for benzocaine and p-aminobenzoic acid including preliminary stability data.

    Science.gov (United States)

    Narang, P K; Bird, G; Crouthamel, W G

    1980-12-01

    A high-performance liquid chromatographic assay was developed that separates and quantitates benzocaine and its primary degradation product, p-aminobenzoic acid. This method is rapid, sensitive, and specific. Preliminary stability data obtained with this method demonstrate its utility for this purpose.

  2. Simultaneous determination of estrogens and progestogens in honey using high performance liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    This work describes the development and validation of a method for the simultaneous determination of 13 estrogens and progestogens in honey by high performance liquid chromatography-tandem mass spectrometry. The target compounds were preconcentrated by solid phase extraction. Pretreatment variables ...

  3. Analysis of native human plasma proteins and haemoglobin for the presence of bityrosine by high-performance liquid chromatography

    DEFF Research Database (Denmark)

    Daneshvar, B; Frandsen, H; Dragsted, L O

    1997-01-01

    fluorescent substance, bityrosine. High-performance liquid chromatography (HPLC) analysis of acid hydrolyzed serum albumin after oxidation with peroxidase/H2O2 or with Cu++/H2O2 showed that bityrosine had been formed whereas oxidation of this protein with Fe(III)/ascorbate did not result in the formation...

  4. High-performance liquid chromatography separation of unsaturated organic compounds by a monolithic silica column embedded with silver nanoparticles.

    Science.gov (United States)

    Zhu, Yang; Morisato, Kei; Hasegawa, George; Moitra, Nirmalya; Kiyomura, Tsutomu; Kurata, Hiroki; Kanamori, Kazuyoshi; Nakanishi, Kazuki

    2015-08-01

    The optimization of a porous structure to ensure good separation performances is always a significant issue in high-performance liquid chromatography column design. Recently we reported the homogeneous embedment of Ag nanoparticles in periodic mesoporous silica monolith and the application of such Ag nanoparticles embedded silica monolith for the high-performance liquid chromatography separation of polyaromatic hydrocarbons. However, the separation performance remains to be improved and the retention mechanism as compared with the Ag ion high-performance liquid chromatography technique still needs to be clarified. In this research, Ag nanoparticles were introduced into a macro/mesoporous silica monolith with optimized pore parameters for high-performance liquid chromatography separations. Baseline separation of benzene, naphthalene, anthracene, and pyrene was achieved with the theoretical plate number for analyte naphthalene as 36,000 m(-1). Its separation function was further extended to cis/trans isomers of aromatic compounds where cis/trans stilbenes were chosen as a benchmark. Good separation of cis/trans-stilbene with separation factor as 7 and theoretical plate number as 76,000 m(-1) for cis-stilbene was obtained. The trans isomer, however, is retained more strongly, which contradicts the long- established retention rule of Ag ion chromatography. Such behavior of Ag nanoparticles embedded in a silica column can be attributed to the differences in the molecular geometric configuration of cis/trans stilbenes.

  5. The Determination of Polyethylene Glycol in Untreated Urine Samples by High Performance Liquid Chromatography for Intestinal Permeability Studies

    DEFF Research Database (Denmark)

    Larsen, Elfinn; Pedersen, Walther Batsberg; Philipsen, E.

    1985-01-01

    Polyethylene glycol in urine samples has been investigated by high performance liquid chromatography. The molecular weights ranged from 634 to 1338. The urine samples were applied to the chromatographic system without any pre-treatment. For samples with a concentration of 0.2% polyethylene glycol...

  6. Preparation and Characterization of a Polymeric Monolithic Column for Use in High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Bindis, Michael P.; Bretz, Stacey Lowery; Danielson, Neil D.

    2011-01-01

    The high-performance liquid chromatography (HPLC) experiment, most often done in the undergraduate analytical instrumentation laboratory course, generally illustrates reversed-phase chromatography using a commercial C[subscript]18 silica column. To avoid the expense of periodic column replacement and introduce a choice of columns with different…

  7. Constructing a LabVIEW-Controlled High-Performance Liquid Chromatography (HPLC) System: An Undergraduate Instrumental Methods Exercise

    Science.gov (United States)

    Smith, Eugene T.; Hill, Marc

    2011-01-01

    In this laboratory exercise, students develop a LabVIEW-controlled high-performance liquid chromatography system utilizing a data acquisition device, two pumps, a detector, and fraction collector. The programming experience involves a variety of methods for interface communication, including serial control, analog-to-digital conversion, and…

  8. Simultaneous determination of dapsone, monoacetyldapsone and pyrimethamine in whole blood and plasma by high-performance liquid chromatography

    DEFF Research Database (Denmark)

    Lemnge, M M; Rønn, A; Flachs, H

    1993-01-01

    A sensitive, selective and rapid reversed-phase high-performance liquid chromatographic method was developed for the simultaneous analysis of dapsone, monoacetyldapsone and pyrimethamine in human whole blood and plasma. The procedure involved extraction of the compounds and the internal standard...

  9. Using reversed phase high performance liquid chromatography to study the complexation of anthocyanins with β-cyclodextrin

    Science.gov (United States)

    Deineka, V. I.; Lapshova, M. S.; Deineka, L. A.

    2014-06-01

    It is shown by means of reversed phase high performance liquid chromatography (RP HPLC) with mobile phases containing additions of β-cyclodextrin that 5-glucosides of cyanidin and pelargonidin form stronger inclusion complexes than 3-glucosides; this is explained by the steric interference of the glucoside radical.

  10. Determination of methyldibromoglutaronitrile in cosmetic products by high-performance liquid chromatography with electrochemical detection. Method validation

    DEFF Research Database (Denmark)

    Rastogi, Suresh Chandra; Zachariae, Claus; Johansen, Jeanne D

    2004-01-01

    An increased frequency of contact allergy to methyldibromoglutaronitrile (MDBGN), a commonly used preservative in cosmetics and other consumer products, has been reported in recent years. A high-performance liquid chromatography (HPLC) method for the determination of MDBGN in cosmetic products has...

  11. High performance liquid chromatography-mass spectrometry analysis of high antioxidant australian fruits with antiproliferative activity against cancer cells

    Directory of Open Access Journals (Sweden)

    Joseph Sirdaarta

    2016-01-01

    Abbreviations used: DPPH: di (phenyl- (2,4,6-trinitrophenyl iminoazanium, HPLC: High-performance liquid chromatography, IC50: The concentration required to inhibit by 50%, LC50: The concentration required to achieve 50% mortality, MS: Mass spectrometry. Ian Edwin Cock

  12. Simultaneous Determination of Caffeine and Vitamin B6 in Energy Drinks by High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Leacock, Rachel E.; Stankus, John J.; Davis, Julian M.

    2011-01-01

    A high-performance liquid chromatography experiment to determine the concentration of caffeine and vitamin B6 in sports energy drinks has been developed. This laboratory activity, which is appropriate for an upper-level instrumental analysis course, illustrates the standard addition method and simultaneous determination of two species. (Contains 1…

  13. NONLINEAR-REGRESSION METHODS FOR MODELING OF HETEROSCEDASTIC RETENTION DATA IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

    NARCIS (Netherlands)

    HENDRIKS, MMWB; COENEGRACHT, PMJ; DOORNBOS, DA

    1994-01-01

    New models have been developed that accurately describe the response surfaces of capacity factors that are a function of changes in the pH and the fraction of organic modifier in reversed-phase high-performance liquid chromatography (RP-HPLC). The purpose of this article is to illustrate one of the

  14. Constructing a LabVIEW-Controlled High-Performance Liquid Chromatography (HPLC) System: An Undergraduate Instrumental Methods Exercise

    Science.gov (United States)

    Smith, Eugene T.; Hill, Marc

    2011-01-01

    In this laboratory exercise, students develop a LabVIEW-controlled high-performance liquid chromatography system utilizing a data acquisition device, two pumps, a detector, and fraction collector. The programming experience involves a variety of methods for interface communication, including serial control, analog-to-digital conversion, and…

  15. Preparation and Characterization of a Polymeric Monolithic Column for Use in High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Bindis, Michael P.; Bretz, Stacey Lowery; Danielson, Neil D.

    2011-01-01

    The high-performance liquid chromatography (HPLC) experiment, most often done in the undergraduate analytical instrumentation laboratory course, generally illustrates reversed-phase chromatography using a commercial C[subscript]18 silica column. To avoid the expense of periodic column replacement and introduce a choice of columns with different…

  16. Simultaneous Determination of Caffeine and Vitamin B6 in Energy Drinks by High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Leacock, Rachel E.; Stankus, John J.; Davis, Julian M.

    2011-01-01

    A high-performance liquid chromatography experiment to determine the concentration of caffeine and vitamin B6 in sports energy drinks has been developed. This laboratory activity, which is appropriate for an upper-level instrumental analysis course, illustrates the standard addition method and simultaneous determination of two species. (Contains 1…

  17. tRNA separation by high-performance liquid chromatography using an aggregate of ODS-Hypersil and trioctylmethylammonium chloride

    NARCIS (Netherlands)

    Bischoff, Rainer; Graeser, E.; Mclaughlin, L.W.

    1983-01-01

    High-performance liquid chromatography on a reversed-phase support treated with a tetraalkylammonium salt was used to separate tRNAs from baker's yeast. While resolution by this column appears to result from both anion-exchange and reversed-phase chromatography, it is the hydrophobic interactions wh

  18. Development and comparison of two dispersive liquid-liquid microextraction techniques coupled to high performance liquid chromatography for the rapid analysis of bisphenol A in edible oils.

    Science.gov (United States)

    Liu, Shuhui; Xie, Qilong; Chen, Jie; Sun, Janzhi; He, Hui; Zhang, Xiaoke

    2013-06-21

    In this study, two novel sample extraction methods for the analysis of bisphenol A (BPA) in edible oils were developed by using liquid-liquid extraction followed by a dispersive liquid-liquid microextraction (LLE-DLLME) and reversed-phase dispersive liquid-liquid microextraction (RP-DLLME). RP-DLLME showed a superior characteristic over LLE-DLLME and other previously reported procedures because of its easy operation, short extraction time, high sensitivity, low organic solvent consumption and waste generation. The optimized extraction conditions of RP-DLLME for 1.0 g of edible oil diluted in 4 mL of n-hexane were: extractant, 100 μL 0.2 M sodium hydroxide solution (80% methanol, v/v); extraction time, 1 min; centrifugation, 3 min. The determination of BPA was carried out by high performance liquid chromatography coupled with a DAD detector. The method offered excellent linearity over a range of 0.010-0.5 μg g(-1) with a correlation coefficient of r>0.997. Intra-day and inter-day repeatability values expressed as relative standard deviation were 1.9% and 5.9%, respectively. The quantitation limit and detection limit were 6.3 and 2.5 ng g(-1). The target analyte was detected in 5 out of 16 edible oil samples. The recovery rates in real samples ranged from 89.5 to 99.7%.

  19. Ultrapreconcentration and determination of organophosphorus pesticides in water by solid-phase extraction combined with dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Chen, Junhua; Zhou, Guangming; Deng, Yongli; Cheng, Hongmei; Shen, Jie; Gao, Yi; Peng, Guilong

    2016-01-01

    Solid-phase extraction coupled with dispersive liquid-liquid microextraction was developed as an ultra-preconcentration method for the determination of four organophosphorus pesticides (isocarbophos, parathion-methyl, triazophos and fenitrothion) in water samples. The analytes considered in this study were rapidly extracted and concentrated from large volumes of aqueous solutions (100 mL) by solid-phase extraction coupled with dispersive liquid-liquid microextraction and then analyzed using high performance liquid chromatography. Experimental variables including type and volume of elution solvent, volume and flow rate of sample solution, salt concentration, type and volume of extraction solvent and sample solution pH were investigated for the solid-phase extraction coupled with dispersive liquid-liquid microextraction with these analytes, and the best results were obtained using methanol as eluent and ethylene chloride as extraction solvent. Under the optimal conditions, an exhaustive extraction for four analytes (recoveries >86.9%) and high enrichment factors were attained. The limits of detection were between 0.021 and 0.15 μg/L. The relative standard deviations for 0.5 μg/L of the pesticides in water were in the range of 1.9-6.8% (n = 5). The proposed strategy offered the advantages of simple operation, high enrichment factor and sensitivity and was successfully applied to the determination of four organophosphorus pesticides in water samples.

  20. Determination of eight fluoroquinolones in groundwater samples with ultrasound-assisted ionic liquid dispersive liquid-liquid microextraction prior to high-performance liquid chromatography and fluorescence detection.

    Science.gov (United States)

    Vázquez, M M Parrilla; Vázquez, P Parrilla; Galera, M Martínez; García, M D Gil

    2012-10-20

    An ultrasound-assisted ionic liquid dispersive liquid-liquid microextraction (US-IL-DLLME) procedure was developed for the extraction of eight fluoroquinolones (marbofloxacin, norfloxacin, ciprofloxacin, lomefloxacin, danofloxacin, enrofloxacin, oxolinic acid and nalidixic acid) in groundwater, using high-performance liquid chromatography with fluorescence detection (HPLC-FD). The ultrasound-assisted process was applied to accelerate the formation of the fine cloudy solution using a small volume of disperser solvent (0.4 mL of methanol), which increased the extraction efficiency and reduced the equilibrium time. For the DLLME procedure, the IL 1-octyl-3-methylimidazolium hexafluorophosphate ([C(8)MIM] [PF(6)]) and methanol (MeOH) were used as extraction and disperser solvent, respectively. By comparing [C(8)MIM] [PF(6)] with 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM] [PF(6)]) and 1-butyl-3-methylimidazolium hexafluorophosphate ([C(4)MIM] [PF(6)]) as extraction solvents, it was observed that when using [C(8)MIM] [PF(6)] the cloudy solution was formed more readily than when using [C(6)MIM] [PF(6)] or [C(4)MIM] [PF(6)]. The factors affecting the extraction efficiency, such as the type and volume of ionic liquid, type and volume of disperser solvent, cooling in ice-water, sonication time, centrifuging time, sample pH and ionic strength, were optimised. A slight increase in the recoveries of fluoroquinolones was observed when an ice-water bath extraction step was included in the analytical procedure (85-107%) compared to those obtained without this step (83-96%). Under the optimum conditions, linearity of the method was observed over the range 10-300 ng L(-1) with correlation coefficient >0.9981. The proposed method has been found to have excellent sensitivity with limit of detection between 0.8 and 13 ng L(-1) and precision with relative standard deviation values between 4.8 and 9.4% (RSD, n=5). Good enrichment factors (122-205) and recoveries (85

  1. High-Performance Liquid Chromatographic-Tandem Mass Spectrometric Determination of Itraconazole in Human Plasma for Bioavailability and Bioequivalence Studies

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Wook; Nam, Dae Young; Kang, Kyoung Hoon; Ha, Kyung Wook; Han, In Hee; Chang, Byung Kon; Yoon, Mi Kyeong; Lee, Jae Hwi [Chung-Ang University, Seoul (Korea, Republic of)

    2006-02-15

    A highly sensitive high-performance liquid chromatographic-tandem mass spectrometric method (HPLC-MSMS) has been developed to quantify itraconazole in human plasma for the purpose of pharmacokinetic studies. Sample preparation was carried out by liquid-liquid extraction using loratadine as an internal standard. Chromatographic separation used a YMC C{sub 18} column, giving an extremely fast total run time of 3 min. The method was validated and used for the bioequivalence study of itraconazole tablets in healthy male volunteers (n = 31). The lower limit of detection proved to be 0.2 ng /mL for itraconazole.

  2. High-performance liquid chromatography using UV detection for the simultaneous quantification of ropivacaine and bupivacaine in human plasma.

    Science.gov (United States)

    Gaudreault, François; Drolet, Pierre; Varin, France

    2009-12-01

    A specific high-performance liquid chromatography assay coupled with UV detection has been developed and validated for the simultaneous determination of ropivacaine and bupivacaine in human plasma. A liquid-liquid back extraction procedure was used to increase specificity, and very good and consistent recoveries were obtained: 93%-95% for ropivacaine and 90%-96% for bupivacaine. The lowest limit of quantification was 4 and 8 ng/mL for ropivacaine and bupivacaine, respectively. The method was sensitive, reproducible (coefficient of variation

  3. Determination of nucleosides in Cordyceps sinensis and Ganoderma lucidum by high performance liquid chromatography method

    Science.gov (United States)

    Khan, Masood Shah; Parveen, Rabea; Mishra, Kshipra; Tulsawani, Rajkumar; Ahmad, Sayeed

    2015-01-01

    Background: Nucleosides are supportive in the regulation and modulation of various physiological processes in body, they acts as precursors in nucleic acid synthesis, enhance immune response, help in absorption of iron and influence the metabolism of fatty acids. Cordyceps sinensis and Ganoderma lucidum are well-known for its use in traditional medicine of China, Nepal and India. They are rich in nucleosides such as adenine, adenosine, cordycepin, etc. Hence, a simple, economic and accurate high-performance liquid chromatography (HPLC) analytical method was proposed for determination of adenine and adenosine for the quality control of plants. Materials and Methods: Chromatographic experiments were conducted on YL9100 HPLC system (South Korea). Reversed-phase chromatography was performed on a C18 column with methanol and dihydrogen phosphate as the mobile phase in isocratic elution method at a flow rate of 1.0 mL/min. Detection was carried out at 254 nm, which gives a sharp peak of adenine and adenosine at a retention time of 6.53 ± 0.02 min and 12.41 ± 0.02, respectively. Results and Discussion: Linear regression analysis data for the calibration plot showed a good linear relationship between response and concentration in the range of 25–200 µg/mL for adenosine and 100–800 µg/mL for adenine with regression coefficient of 0.999 and 0.996, respectively. The adenine was found 0.16% and 0.71% w/w in G. lucidum and in C. sinensis, respectively, and adenosine was found to be 0.14% w/w in G. lucidum whereas absent in C. sinensis. Conclusion: The developed HPLC method for the quantification of adenosine and adenine can be used for the quality control and standardization of crude drug and for the different herbal formulations, in which adenine and adenosine are present as major constituents. The wide linearity range, sensitivity, accuracy, and simple mobile phase imply the method is suitable for routine quantification of adenosine and adenine with high precision and

  4. Determination of theoretical retention times for peptides analyzed by reversed- -phase high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Jerzy Dziuba

    2011-06-01

    Full Text Available   Background. Peptides are important components of foods mainly due to their biological activity. The basic method of their identification is reversed phase high-performance liquid chromatography coupled with electrospray-ionization mass spectrometry (RP-HPLC-ESI-MS. Retention time (tR prediction in silico is very helpful in analysis of multicomponent peptide mixtures. One of problems associated with RP-HPLC-ESI-MS is deterioration of mass spectra quality by trifluoroacetic acid (TFA. This problem can be avoided through the use of chromatographic columns designed for work with low TFA concentrations in mobile phase. The objective of this study was to determine the correlations between peptide retention times predicted with the use of a program available on-line and experimental retention times obtained using the column working with low TFA concentrations. Material and methods. The set of synthetic peptides and bovine α-lactalbumin fragments (18 peptides was used in the experiment. Theoretical retention times were calculated using Sequence Specific Retention Calculator (SSRC program. The experimental retention times were measured via RP-HPLC-ESI-MS method using column working with low TFA content. The dependence between theoretical and experimental tR was expressed via empirical equations. Results. The best correlation between theoretical and experimental retention times of peptides containing at least four amino acid residues has been obtained when third order polynomial (R² = 0.9536. Prediction quality for di- and tripeptides was significantly lower. The method described can be applied for cysteine-containing peptides although our sample preparation procedure did not include modification of this amino acid, taken into attention by SSRC program. Conclusions. The results of this study validate the usefulness of a third degree polynomial as a simple function describing the correlation between peptide retention times predicted by an on

  5. Determination of free amino acids in burley tobacco by high performance liquid chromatography

    Science.gov (United States)

    Jing, Yanqiu; Zhang, Baolin; Yuan, Xiuxiu; Gao, Yuzhen; Lu, Ping; Wang, Weifeng; Xu, Min

    2015-01-01

    A reversed-phase high performance liquid chromatographic method was developed for determining free amino acids in burley tobacco. The test was done by OPA/3-mercaptopropionic acid as the pre-column derivatizing reagent. Chromatographic column was Elitte C18 column (4.6 mm × 250 mm i.d., 5 μm). Mobile phase A was 18 mol/l NaAc (pH7.2) including 0.002%(v/v) triethylamine and 0.3%(v/v) furanidine. Mobile phase B was 100 mol/l NaAc (pH7.2)–acetonitrile–methanol (v/v = 1:2:2). The column temperature was 40 °C and the flow rate was 1.0 ml/min. The fluorescence detector was used with 350 nm excitation wave length and 450 nm emission wave length. The average recoveries of the method ranged from 95.3–100.7% with the relative standard deviation of 2.32–9.24%. The method is simple, accurate and has good repeatability. The results of the determination of seventeen kinds of free amino acids in burley leaves were produced by the way of different ratios of cake fertilizer and inorganic fertilizer. The results show that Aspartic acid has the highest content however ratio of cake fertilizer and inorganic fertilizer. The contents of most of the free amino acids are increased and then gradually decreased with the increase in organic manure. The contents of most of the free amino acids are very close at 15:85% ratio and 30:70% ratio of cake fertilizer and inorganic fertilizer. The total amount of free amino acids is the highest at 30:70% ratio of cake fertilizer and inorganic fertilizer. Considering comprehensively, the quality of burley leaves is the best at 30:70% ratio of cake fertilizer and inorganic fertilizer. PMID:26858568

  6. Improved method for the determination of triacylglycerols in olive oils by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Cert, A.

    2003-06-01

    Full Text Available The analysis of triacylglycerols has great importance as quality control and origin determination aid in olive oils analytical methodologies. New improvements in the analysis of triacylglycerols by high-performance liquid chromatography in olive oils are developed in order to increase the separation between LLL/OLLn and OLL/OOLn critical pairs used for detection of seed oils in olive oils. Elution with acetone/acetonitrile (55:45 using gradient temperature and isothermal elution with propionitrile were investigated, in comparison with the European Union official method. The best resolution was achieved using propionitrile at 20 ºC. Although the HPLC profile was similar using propionitrile and acetone/acetonitrile, differences in minor triacylglycerols contributing to each HPLC peak were encountered. The precision of the method was good.El análisis de triacilgliceroles tiene gran importancia como herramienta en el control de calidad y en la determinación del origen de los aceites de oliva. Nuevas mejoras en el análisis de triacilgliceroles en aceite de oliva mediante cromatografía líquida de alta eficacia se han desarrollado para mejorar la separación entre las parejas críticas LLL/OLLn y OLL/OOLn usadas en la detección de aceites de semilla en aceite de oliva. Eluciones con acetona/acetonitrilo (55:45 usando gradiente de temperatura y elución con propionitrilo en condiciones isotérmicas han sido investigadas en comparación con el método oficial de la Unión Europea. La mejor resolución se consiguió usando propionitrilo como eluyente a 20 ºC. Aunque el perfil cromatográfico obtenido usando propionitrilo fue similar al obtenido usando acetona/acetonitrilo, se encontraron diferencias en los triacilgliceroles minoritarios que contribuyen a cada pico cromatográfico. La precisión del método fue buena.

  7. Determination of nucleosides in Cordyceps sinensis and Ganoderma lucidum by high performance liquid chromatography method

    Directory of Open Access Journals (Sweden)

    Masood Shah Khan

    2015-01-01

    Full Text Available Background: Nucleosides are supportive in the regulation and modulation of various physiological processes in body, they acts as precursors in nucleic acid synthesis, enhance immune response, help in absorption of iron and influence the metabolism of fatty acids. Cordyceps sinensis and Ganoderma lucidum are well-known for its use in traditional medicine of China, Nepal and India. They are rich in nucleosides such as adenine, adenosine, cordycepin, etc. Hence, a simple, economic and accurate high-performance liquid chromatography (HPLC analytical method was proposed for determination of adenine and adenosine for the quality control of plants. Materials and Methods: Chromatographic experiments were conducted on YL9100 HPLC system (South Korea. Reversed-phase chromatography was performed on a C18 column with methanol and dihydrogen phosphate as the mobile phase in isocratic elution method at a flow rate of 1.0 mL/min. Detection was carried out at 254 nm, which gives a sharp peak of adenine and adenosine at a retention time of 6.53 ± 0.02 min and 12.41 ± 0.02, respectively. Results and Discussion: Linear regression analysis data for the calibration plot showed a good linear relationship between response and concentration in the range of 25–200 µg/mL for adenosine and 100–800 µg/mL for adenine with regression coefficient of 0.999 and 0.996, respectively. The adenine was found 0.16% and 0.71% w/w in G. lucidum and in C. sinensis, respectively, and adenosine was found to be 0.14% w/w in G. lucidum whereas absent in C. sinensis. Conclusion: The developed HPLC method for the quantification of adenosine and adenine can be used for the quality control and standardization of crude drug and for the different herbal formulations, in which adenine and adenosine are present as major constituents. The wide linearity range, sensitivity, accuracy, and simple mobile phase imply the method is suitable for routine quantification of adenosine and adenine with

  8. Validation of high performance liquid chromatography method for determination of meloxicam loaded PEGylated nanocapsules

    Directory of Open Access Journals (Sweden)

    Francine Rodrigues Ianiski

    2015-12-01

    Full Text Available abstract A method to ensure that an analytical method will produce reliable and interpretable information about the sample must first be validated, making sure that the results can be trusted and traced. In this study, we propose to validate an analytical high performance liquid chromatography (HPLC method for the quantitation of meloxicam loaded PEGylated nanocapsules(M-PEGNC. We performed a validation study, evaluated parameters including specificity, linearity, quantification limit, detection limit, accuracy, precision and robustness. PEGylated nanocapsules were prepared by interfacial deposition of preformed polymer, and the particle size, polydispersity index, zeta potential, pH value and encapsulation efficiency were characterized. The proposed HPLC method provides selective, linear results in the range of 1.0-40.0 μg/mL; quantification and detection limits were 1.78 μg/mL and 0.59 μg/mL, respectively; relative standard deviation for repeatability was 1.35% and intermediate precision was 0.41% and 0.61% for analyst 1 and analyst 2, respectively; accuracy between 99.23 and 101.79%; robustness between 97.13 and 98.45% for the quantification of M-PEGNC. Mean particle diameters were 261 ± 13 nm and 249 ± 20 nm, polydispersity index was 0.15 ± 0.07 and 0.17 ± 0.06, pH values were 5.0 ± 0.2 and 5.2 ± 0.1, and zeta-potential values were -37.9 ± 3.2 mV e -31.8 ± 2.8 mV for M-PEGNC and placebo(B-PEGNC, respectively. In conclusion, the proposed analytical method is suitable for the quality control of M-PEGNC. Moreover, suspensions showed monomodal size distributions and low polydispersity index indicating high homogeneity of formulations with narrow size distributions, and appropriate pH and zeta potential. The extraction process was efficient for release of meloxicam from nanostructured systems.

  9. Analysis of some selected catechins and caffeine in green tea by high performance liquid chromatography.

    Science.gov (United States)

    El-Shahawi, M S; Hamza, A; Bahaffi, S O; Al-Sibaai, A A; Abduljabbar, T N

    2012-10-15

    Green tea seems to have a positive impact on health due to the catechins-found as flavanols. Thus, the present study was aimed to develop a low cost reversed phase high performance liquid chromatographic (HPLC) method for simultaneous determination of flavanol contents, namely catechin (C), epicatechin (EC), epigallocatechin (EGC), epicatechin 3-gallate (ECG) and epigallocatechin 3-gallate (EGCG) and caffeine in 29 commercial green tea samples available in a Saudi Arabian local market. A C-18 reversed-phase column, acetonitrile-trifluoroacetic acid as a mobile phase, coupled with UV detector at 205 nm, was successfully used for precise analysis of the tested analytes in boiled water of digested tea leaves. The average values of N (No. of theoretical plates), HETP (height equivalent of theoretical plates) and R(s) (separation factor) (at 10 μg ml(-1) of the catechins EC, EGC, EGCG and ECG) were 2.6×10(3)±1.2×10(3), 1.7×10(-3)±4.7×10(-4) cm and 1.7±5.53×10(-2), respectively. The developed HPLC method demonstrated excellent performance, with low limits of detection (LOD) and quantification (LOQ) of the tested catechins of 0.004-0.05 μg ml(-1) and 0.01-0.17 μg ml(-1), respectively, and recovery percentages of 96-101%. The influence of infusion time (5-30 min) and temperature on the content of the flavanols was investigated by HPLC. After a 5 min infusion of the tea leaves, the average concentrations of caffeine, catechin, EC, EGC, ECG and EGCG were found to be in the ranges 0.086-2.23, 0.113-2.94, 0.58-10.22, 0.19-24.9, 0.22-13.9 and 1.01-43.3 mg g(-1), respectively. The contents of caffeine and catechins followed the sequence: EGCG>EGC>ECG>EC>C>caffeine. The method was applied satisfactorily for the analysis of (+)-catechin, even at trace and ultra trace concentrations of catechins. The method was rapid, accurate, reproducible and ideal for routine analysis.

  10. Analysis of sup 99m Tc-labeled radiopharmaceuticals by high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Muto, Toshio (Tokyo Metropolitan Isotope Research Center (Japan))

    1990-02-01

    High-performance liquid chromatography (HPLC) equiped with on line radiometric and optical detectors (i.e. radio-HPLC) have been applied to the radiochemical analysis of commonly-used {sup 99m}Tc-radio pharma ceuticals with a view point to check the radiochemical purities of the compounds. Chromatographic conditions were determined by examination of the types of column, mobile phase and pH. An aqueous size-exclusion (Shim-pack Diol-300) and reversed-phase column (Zorbax-ODS) were found to be suitable for {sup 99m}Tc-HSA and the other {sup 99m}Tc-agents, respectively. The analysis of low molecular weight {sup 99m}Tc-agents (e.g. {sup 99m}Tc-DTPA, {sup 99m}Tc-DMSA, {sup 99m}Tc-pyrophosphate, {sup 99m}Tc-phytic acid, {sup 99m}Tc-MDS, {sup 99m}Tc-HMDP) were done by reversed-phaseion pairing chromatography using a optimized mobile phase consisted on a mixture of 50 mM phosphate buffer (pH 7.0) and 2 mM TBA (tetra nbutyl) ammonium hydroxide in 30 % methanol. The mobile phases for analysis of medium molecular weight {sup 99m}Tc-HSA were consisted of a mixture of 50 mM phosphate buffer (ph 7.0) in 30 % methanol, and a mixtures of 1 % SDS (sodium dodecyl sulfonate) in Tris buffer (pH. 7.0), respectively. It was apparent from the radio-chromatograms obtained from these chromatographic conditions, that impurity of {sup 99m}TcO{sub 4} was observed in {sup 99m}Tc-pyrophosphate, {sup 99m}Tc-phytic acid, {sup 99m}Tc-MDP, {sup 99m}Tc-HMDP, and impurities of {sup 99m}Tc-labeled species and {sup 99m}TcO{sub 4}, were observed in {sup 99m}Tc-HIDA, {sup 99m}Tc-HIDA, {sup 99m}Tc-HSA. The radiochemical impurities of the {sup 99m}Tc-radiopharmaceuticals were ranged between 90 and 100 %. From these results, radio-HPLC has been shown to be suitable method for analysis of {sup 99m}Tc-radiopharmaceuticals, with rapidity and excellent precision. (author).

  11. Low Density Solvent-Based Dispersive Liquid-Liquid Microextraction for the Determination of Synthetic Antioxidants in Beverages by High-Performance Liquid Chromatography

    Science.gov (United States)

    Çabuk, Hasan; Köktürk, Mustafa

    2013-01-01

    A simple and efficient method was established for the determination of synthetic antioxidants in beverages by using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography with ultraviolet detection. Butylated hydroxy toluene, butylated hydroxy anisole, and tert-butylhydroquinone were the antioxidants evaluated. Experimental parameters including extraction solvent, dispersive solvent, pH of sample solution, salt concentration, and extraction time were optimized. Under optimal conditions, the extraction recoveries ranged from 53 to 96%. Good linearity was observed by the square of correlation coefficients ranging from 0.9975 to 0.9997. The relative standard deviations ranged from 1.0 to 5.2% for all of the analytes. Limits of detection ranged from 0.85 to 2.73 ng mL−1. The method was successfully applied for determination of synthetic antioxidants in undiluted beverage samples with satisfactory recoveries. PMID:23853535

  12. Low density solvent-based dispersive liquid-liquid microextraction for the determination of synthetic antioxidants in beverages by high-performance liquid chromatography.

    Science.gov (United States)

    Çabuk, Hasan; Köktürk, Mustafa

    2013-01-01

    A simple and efficient method was established for the determination of synthetic antioxidants in beverages by using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography with ultraviolet detection. Butylated hydroxy toluene, butylated hydroxy anisole, and tert-butylhydroquinone were the antioxidants evaluated. Experimental parameters including extraction solvent, dispersive solvent, pH of sample solution, salt concentration, and extraction time were optimized. Under optimal conditions, the extraction recoveries ranged from 53 to 96%. Good linearity was observed by the square of correlation coefficients ranging from 0.9975 to 0.9997. The relative standard deviations ranged from 1.0 to 5.2% for all of the analytes. Limits of detection ranged from 0.85 to 2.73 ng mL(-1). The method was successfully applied for determination of synthetic antioxidants in undiluted beverage samples with satisfactory recoveries.

  13. Determination of three estrogens and bisphenol A by functional ionic liquid dispersive liquid-phase microextraction coupled with ultra-high performance liquid chromatography and ultraviolet detection.

    Science.gov (United States)

    Jiang, Yuehuang; Tang, Tingting; Cao, Zhen; Shi, Guoyue; Zhou, Tianshu

    2015-06-01

    A hydroxyl-functionalized ionic liquid, 1-hydroxyethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide, was employed in an improved dispersive liquid-phase microextraction method coupled with ultra high performance liquid chromatography for the enrichment and determination of three estrogens and bisphenol A in environmental water samples. The introduced hydroxyl group acted as the H-bond acceptor that dispersed the ionic liquid effectively in the aqueous phase without dispersive solvent or external force. Fourier transform infrared spectroscopy indicated that the hydroxyl group of the cation of the ionic liquid enhanced the combination of extractant and analytes through the formation of hydrogen bonds. The improvement of the extraction efficiency compared with that with the use of alkyl ionic liquid was proved by a comparison study. The main parameters including volume of extractant, temperature, pH, and extraction time were investigated. The calibration curves were linear in the range of 5.0-1000 μg/L for estrone, estradiol, and bisphenol A, and 10.0-1000 μg/L for estriol. The detection limits were in the range of 1.7-3.4 μg/L. The extraction efficiency was evaluated by enrichment factor that were between 85 and 129. The proposed method was proved to be simple, low cost, and environmentally friendly for the determination of the four endocrine disruptors in environmental water samples.

  14. Analysis of the Constituents in “Zhu She Yong Xue Shuan Tong” by Ultra High Performance Liquid Chromatography with Quadrupole Time-of-Flight Mass Spectrometry Combined with Preparative High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Lin-Lin Wang

    2015-11-01

    Full Text Available “Zhu She Yong Xue Shuan Tong” lyophilized powder (ZSYXST, consists of a series of saponins extracted from Panax notoginseng, which has been widely used in China for the treatment of strokes. In this study, an ultra-high performance liquid chromatography with quadrupole time-of-flight mass spectrometry (UHPLC-Q-TOF/MS combined with preparative high performance liquid chromatography (PHPLC method was developed to rapidly identify both major and minor saponins in ZSYXST. Some high content components were removed through PHPLC in order to increase the sensitivity of the trace saponins. Then, specific characteristic fragment ions in both positive and negative mode were utilized to determine the types of aglycone, saccharide, as well as the saccharide chain linkages. As a result, 94 saponins, including 20 pairs of isomers and ten new compounds, which could represent higher than 98% components in ZSYXST, were identified or tentatively identified in commercial ZSYXST samples.

  15. Determination of Beta-Lactam residues in milk by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Roseane Brandão de Brito

    2006-01-01

    Full Text Available A high performance liquid chromatographic method to assay beta-lactam residues in milk was developed and validated. Milk samples were spiked with standard solutions and deproteinated. The extract was cleaned-up on C18 SPE cartridge, the antibiotics eluted with acetonitrile:water (50:50 v/v and derivatized with acetic anhydride and 1-methyl-imidazole solution containing HgCl2. The chromatographic analysis was performed on C18 column using mobile phase consisting of acetonitrile and phosphate buffer (pH 6.5 in the presence of Na2S2O3 gradient and detection at 325 nm. The method was selective for ampicillin, penicillin G and penicillin V, the latter used as internal standard. Average recoveries for ampicillin and penicillin G ranged, respectively, from 60.0% to 104.9% and from 82.7% to 109.2%, with coefficients of variation from 11.1% to 24.6%, and from 2.1% to 25.2%, indicating accuracy and precision. Detection limit of 4.0 µg/L for ampicillin and 3.0 µg/L for penicillin G, and quantification limits of 4.0 µg/L for both were estimated.Um método para determinar resíduos de antibióticos beta-lactâmicos em leite por cromatografia líquida de alta eficiência (CLAE foi desenvolvido e validado. Amostras brancas foram adicionadas de padrão e desproteinizadas. O extrato foi purificado por extração em fase sólida C18, os antibióticos eluídos com acetonitrila:água (50:50 v/v e posteriormente derivatizados com anidrido acético e solução de 1-metil-imidazol contendo HgCl2. A análise cromatográfica foi realizada utilizando coluna C18, fase móvel composta por acetonitrila e tampão fosfato pH 6,5, na presença de Na2S2O3 em gradiente e detecção a 325 nm. O método foi seletivo para ampicilina, penicilina G e penicilina V, sendo este último utilizado como padrão interno. As médias de recuperação para ampicilina e penicilina G situaram-se, respectivamente, na faixa de 60,0% a 104,9% e de 82,7% a 109,2%, com coeficientes de varia

  16. Determination of multiple phytohormones in fruits by high-performance liquid chromatography with fluorescence detection using dispersive liquid-liquid microextraction followed by precolumn fluorescent labeling.

    Science.gov (United States)

    Li, Guoliang; Lu, Shuaimin; Wu, Hongliang; Chen, Guang; Liu, Shucheng; Kong, Xiaojian; Kong, Weiheng; You, Jinmao

    2015-01-01

    Plant hormone determination in food matrices has attracted more and more attention because of their potential risks to human health. However, analytical methods for the analysis of multiple plant hormones remain poorly investigated. In the present study, a convenient, selective, and ultrasensitive high-performance liquid chromatography method for the simultaneous determination of multiple classes of plant hormones has been developed successfully using dispersive liquid-liquid microextraction followed by precolumn fluorescent labeling. Eight plant hormones in fruits including jasmonic acid, 12-oxo-phytodienoic acid, indole-3-acetic acid, 3-indolybutyric acid, 3-indolepropionic acid, gibberellin A3 , 1-naphthylacetic acid, and 2-naphthaleneacetic acid were analyzed by this method. The conditions employed for dispersive liquid-liquid microextraction were optimized systematically. The linearity for all plant hormones was found to be >0.9993 (R(2) values). This method offered low detection limits of 0.19-0.44 ng/mL (at a signal-to-noise ratio of 3), and method accuracies were in the range of 92.32-103.10%. The proposed method was applied to determine plant hormones in five kinds of food samples, and this method can achieve a short analysis time, low threshold levels of detection, and a high specificity for the analysis of targeted plant hormones present at trace level concentrations in complex matrices.

  17. Rapid determination of some psychotropic drugs in complex matrices by tandem dispersive liquid-liquid microextraction followed by high performance liquid chromatography.

    Science.gov (United States)

    Asghari, Alireza; Fahimi, Ebrahim; Bazregar, Mohammad; Rajabi, Maryam; Boutorabi, Leila

    2017-03-15

    Simple and rapid determinations of some psychotropic drugs in some pharmaceutical wastewater and human plasma samples were successfully accomplished via the tandem dispersive liquid-liquid microextraction combined with high performance liquid chromatography-ultraviolet detection (TDLLME-HPLC-UV). TDLLME of the three psychotropic drugs clozapine, chlorpromazine, and thioridazine was easily performed through two consecutive dispersive liquid-liquid microextractions. By performing this convenient method, proper sample preconcentrations and clean-ups were achieved in just about 7min. In order to achieve the best extraction efficiency, the effective parameters involved were optimized. The optimal experimental conditions consisted of 100μL of CCl4 (as the extraction organic solvent), and the pH values of 13 and 2 for the donor and acceptor phases, respectively. Under these optimum experimental conditions, the proposed TDLLME-HPLC-UV technique provided a good linearity in the range of 5-3000ngmL(-1) for the three psychotropic drugs with the correlation of determinations (R(2)s) higher than 0.996. The limits of quantification (LOQs) and limits of detection (LODs) obtained were 5.0ngmL(-1) and 1.0-1.5ngmL(-1), respectively. Also the proper enrichment factors (EFs) of 96, 99, and 88 for clozapine, chlorpromazine, and thioridazine, respectively, and good extraction repeatabilities (relative standard deviations below 9.3%, n=5) were obtained.

  18. Recent advances in ultra-high performance liquid chromatography for the analysis of traditional chinese medicine

    Science.gov (United States)

    Traditional Chinese medicines (TCMs) have been widely used for the prevention and treatment of various diseases for thousands of years in China. Ultra Performance Liquid Chromatography (UHPLC) is a relatively new technique offering new possibilities in liquid chromatography. This paper reviews recen...

  19. High performance discharges in the Lithium Tokamak eXperiment with liquid lithium wallsa)

    Science.gov (United States)

    Schmitt, J. C.; Bell, R. E.; Boyle, D. P.; Esposti, B.; Kaita, R.; Kozub, T.; LeBlanc, B. P.; Lucia, M.; Maingi, R.; Majeski, R.; Merino, E.; Punjabi-Vinoth, S.; Tchilingurian, G.; Capece, A.; Koel, B.; Roszell, J.; Biewer, T. M.; Gray, T. K.; Kubota, S.; Beiersdorfer, P.; Widmann, K.; Tritz, K.

    2015-05-01

    The first-ever successful operation of a tokamak with a large area (40% of the total plasma surface area) liquid lithium wall has been achieved in the Lithium Tokamak eXperiment (LTX). These results were obtained with a new, electron beam-based lithium evaporation system, which can deposit a lithium coating on the limiting wall of LTX in a five-minute period. Preliminary analyses of diamagnetic and other data for discharges operated with a liquid lithium wall indicate that confinement times increased by 10× compared to discharges with helium-dispersed solid lithium coatings. Ohmic energy confinement times with fresh lithium walls, solid and liquid, exceed several relevant empirical scaling expressions. Spectroscopic analysis of the discharges indicates that oxygen levels in the discharges limited on liquid lithium walls were significantly reduced compared to discharges limited on solid lithium walls. Tokamak operations with a full liquid lithium wall (85% of the total plasma surface area) have recently started.

  20. Determination of methyldibromoglutaronitrile in cosmetic products by high performance liquid chromatography with electrochemical detection.

    Science.gov (United States)

    Rooselaar, J; Weyland, J W

    1993-02-01

    Synopsis A method for the determination of methyldibromoglutaronitrile in cosmetic products is described. Reversed phase high performance liquid chromatography and reductive electrochemical detection is employed to provide for improved selectivity and detectability compared to alternative methods. The method detects 0.002% methyldibromoglutaronitrile in cosmetic products and has a linear range from 0.006 up to 0.06%, which can easily be extended to the legally allowed limit of 0.1% by means of a simple dilution step. At a level of 0.03% the coefficient of variation was estimated to be 1.7%. Recoveries measured were between 98 and 100%. The method has been subjected to a ruggedness test, which indicated that it was stable, but slightly sensitive for a decrease in the detection potential. More than 130 cosmetic products have been analysed using the method. In 19 samples methyldibromoglutaronitrile was detected in concentrations varying between 0.002% and 0.030%. Résumé Une méthode a été mise au point pour la détermination du methyldibromoglutaronitrile, un conservateur cosmétique dont l'utilisation est croissante. La méthode utilise la chromatographie liquide à haute performance avec détection électrochimique pour permettre une amélioration de la détection et de la spécificité. Selon une procédure simple, le methyldibromoglutaronitrile est séparé sur une colonne 100 RP8 (lichosphere MERCK) avec une phase mobile constituee d'eau et d'acétone (60/40 v/v) avec un ajout de sulfate de sodium et du chlorure de sodium pour obtenir des concentrations de 0.02 M et 0.002 M respectivement. Une électrode en or a été utilisée pour la détection avec un potentiel de fonctionnement de -0.6 V réductif. Une détection par pulsation a été nécessaire pour obtenir une réponse stable. Le détecteur a été programmé pourgarder l'électrode pour 10 ms à 1 V, 10 ms à-1 V (réductif) et à-0.6 V pour 100 ms, ce potentiel a été utilisé comme mesure. Des

  1. Quantification of urinary uric acid in the presence of thymol and thimerosal by high-performance liquid chromatography

    Science.gov (United States)

    Chen, Y.; Pietrzyk, R. A.; Whitson, P. A.

    1997-01-01

    A high-performance liquid chromatographic method was developed as an alternative to automated enzymatic analysis of uric acid in human urine preserved with thymol and/or thimerosal. Uric acid (tR = 10 min) and creatinine (tR = 5 min) were separated and quantified during isocratic elution (0.025 M acetate buffer, pH 4.5) from a mu Bondapak C18 column. The uric-acid peak was identified chemically by incubating urine samples with uricase. The thymol/thimerosal peak appeared at 31 min during the washing step and did not interfere with the analysis. We validated the high-performance liquid chromatographic method for linearity, precision and accuracy, and the results were found to be excellent.

  2. Detection of argan oil adulteration with vegetable oils by high-performance liquid chromatography-evaporative light scattering detection.

    Science.gov (United States)

    Salghi, Rachid; Armbruster, Wolfgang; Schwack, Wolfgang

    2014-06-15

    Triacylglycerol profiles were selected as indicator of adulteration of argan oils to carry out a rapid screening of samples for the evaluation of authenticity. Triacylglycerols were separated by high-performance liquid chromatography-evaporative light scattering detection. Different peak area ratios were defined to sensitively detect adulteration of argan oil with vegetable oils such as sunflower, soy bean, and olive oil up to the level of 5%. Based on four reference argan oils, mean limits of detection and quantitation were calculated to approximately 0.4% and 1.3%, respectively. Additionally, 19 more argan oil reference samples were analysed by high-performance liquid chromatography-refractive index detection, resulting in highly comparative results. The overall strategy demonstrated a good applicability in practise, and hence a high potential to be transferred to routine laboratories. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Discrimination of Semen cassiae from two related species based on the multivariate analysis of high-performance liquid chromatography fingerprints.

    Science.gov (United States)

    Tang, Liying; Wu, Hongwei; Zhou, Xidan; Xu, Yilong; Zhou, Guohong; Wang, Ting; Kou, Zhenzhen; Wang, Zhuju

    2015-07-01

    A simple and efficient high-performance liquid chromatography fingerprint method was developed to discriminate Semen cassiae from two related species: Cassia obtusifolia L. (CO) and Cassia tora L. (CT), the seeds of which are abbreviated as COS and CTS, respectively. 22 major bioactive ingredients in 42 samples (20 COS and 22 CTS) collected from different provinces of China were identified. The statistical methods included similarity analysis and partial least-squares discriminant analysis. The pattern analysis method was specific and could be readily used for the comprehensive evaluation of Semen cassiae samples. Therefore, high-performance liquid chromatography fingerprint in combination with pattern analysis provided a simple and reliable method for discriminating between COS and CTS. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Enantiomeric high-performance liquid chromatography resolution and absolute configuration of 6β-benzoyloxy-3α-tropanol.

    Science.gov (United States)

    Muñoz, Marcelo A; González, Natalia; Joseph-Nathan, Pedro

    2016-07-01

    The absolute configuration of the naturally occurring isomers of 6β-benzoyloxy-3α-tropanol (1) has been established by the combined use of chiral high-performance liquid chromatography with electronic circular dichroism detection and optical rotation detection. For this purpose (±)-1, prepared in two steps from racemic 6-hydroxytropinone (4), was subjected to chiral high-performance liquid chromatography with electronic circular dichroism and optical rotation detection allowing the online measurement of both chiroptical properties for each enantiomer, which in turn were compared with the corresponding values obtained from density functional theory calculations. In an independent approach, preparative high-performance liquid chromatography separation using an automatic fraction collector, yielded an enantiopure sample of OR (+)-1 whose vibrational circular dichroism spectrum allowed its absolute configuration assignment when the bands in the 1100-950 cm(-1) region were compared with those of the enantiomers of esters derived from 3α,6β-tropanediol. In addition, an enantiomerically enriched sample of 4, instead of OR (±)-4, was used for the same transformation sequence, whose high-performance liquid chromatography follow-up allowed their spectroscopic correlation. All evidences lead to the OR (+)-(1S,3R,5S,6R) and OR (-)-(1R,3S,5R,6S) absolute configurations, from where it follows that samples of 1 isolated from Knightia strobilina and Erythroxylum zambesiacum have the OR (+)-(1S,3R,5S,6R) absolute configuration, while the sample obtained from E. rotundifolium has the OR (-)-(1R,3S,5R,6S) absolute configuration.

  5. Investigation of retention and chiral recognition mechanism using quantitative structure-enantioselectivity retention relationship in high performance liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    CHEN, Hui; LU, Xian-Yu; GAO, Ru-Yu; HUANG, Jun-Min; YANG, Hua-Zheng; WANG, Qin-Sun

    2000-01-01

    The enantiomers of a series of fourteen O-ethyl O-(substituted) phenyl N-isopropyl-phosphoroamidothioates have been separated by high performance liquid chromatography (HPLC) on the Pirkde-type chiral stationary phase. Seven molecular descriptors were lculated and four .significant descriptors were chosen to correlate against the experimental Ink′ values in order to form thequantitative structure-enantioselectivity retention relationships (QSERRs). Through the QSERRs, the retention and enantioselectivity meehanism were examined.

  6. Protective properties of wine products and the role of high performance liquid chromatography in the study of these properties

    Science.gov (United States)

    Ulyanova, E. V.; Larionov, O. G.; Revina, A. A.; Andrievskaya, D. V.; Urusova, L. M.; Fenin, A. A.

    2013-12-01

    Data on the biologically active substances present in wines and wine products, the methods of their determination, and changes under chemical, radiation and other types of action are generalized. The role of high performance liquid chromatography in the studies of the protective properties of wines is demonstrated. Particular attention is devoted to problems of counterfeiting of wine products and the possibility to reveal it by using amperometric determination of the antioxidant activity. The bibliography includes 117 references.

  7. Isolation of lignans glycosides from Alibertia sessilis (Vell.) K. Schum. (Rubiaceae) by preparative high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Silva, V.C. da; Bolzani, V. da S.; Lopes, M.N. [UNESP, Araraquara, SP (Brazil). Inst. de Quimica. Dept. de Quimica Organica; Silva, G.H. [Universidade Federal de Sergipe, Aracaju, SE (Brazil). Dept. de Quimica]. E-mail: mnlopes@iq.unesp.br

    2006-10-15

    Enantiomeric aglycone lignans contained in a mixture were separated from a fraction of the extract of the stems of Alibertia sessilis (Vell.) K. Schum. (Rubiaceae) by preparative high-performance liquid chromatography. An efficient and fast separation can be achieved with methanol-water (30:70, v/v). Their structures were identified as (+)-lyoniresinol 3{alpha}-O-{beta}-glucopyranoside and (-)-lyoniresinol 3{alpha}-O-{beta}-glucopyranoside, being reported for the first time in Rubiaceae. (author)

  8. The use of high-performance liquid chromatography in the quality control of oxytocin, vasopressin and synthetic analogues.

    Science.gov (United States)

    Maxl, F; Siehr, W

    1989-01-01

    Optimized C18 reversed-phase systems for oxytocin, desamino-oxytocin, lysine-vasopressin, ornithine-vasopressin and felypressin with gradient elution are discussed, focussing on precision, selectivity and ruggedness of the methods. Data from collaborative studies are presented, demonstrating the equivalence of high-performance liquid chromatography (HPLC) assays to bioassays. The findings suggest that HPLC is an excellent alternative to the time-consuming and less reliable animal testing.

  9. Determination of Polycyclic Aromatic Hydrocarbons in Automobile Exhaust by Means of High-Performance Liquid Chromatography with Fluorescence Detection

    DEFF Research Database (Denmark)

    Nielsen, Tom

    1979-01-01

    A chromatographic method has been developed and applied to the determination of polycyclic aromatic hydrocarbons (PAHs) in particulate matter in automobile exhaust, in petrols, and in crankcase oils. The PAHs were purified from other organic compounds by thin-layer chromatography, separated by high......-performance liquid chromatography, and measured by means of on-line fluorescence detection. The identities of the PAHs were verified by comparing the emission spectra obtained by a stop-flow technique with those of standard PAHs...

  10. Simultaneous determination of 20 food additives by high performance liquid chromatography with photo-diode array detector

    Institute of Scientific and Technical Information of China (English)

    Kang Ma; Ya Nan Yang; Xiao Xiong Jiang; Min Zhao; Ye Qiang Cai

    2012-01-01

    An efficient and accurate analytical method was developed for the simultaneous determination of 20 synthetic food additives,including three sweeteners,seven food colorants,nine synthetic preservatives and caffeine,by high performance liquid chromatography (HPLC) with photodiode array detector (PDA).This method permits the detection of food additives at very low concentrations (0.005-0.150 μg/mL).The applicability was verified by the determination of food additives present in various foodstuffs.

  11. Rapid determination of quinolones in cosmetic products by ultra high performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Liu, Shao-Ying; Huang, Xi-Hui; Wang, Xiao-Fang; Jin, Quan; Zhu, Guo-Nian

    2014-05-01

    This study developed an improved analytical method for the simultaneous quantification of 13 quinolones in cosmetics by ultra high performance liquid chromatography combined with ESI triple quadrupole MS/MS under the multiple reaction monitoring mode. The analytes were extracted and purified by using an SPE cartridge. The limits of quantification ranged from 0.03 to 3.02 μg/kg. The precision for determining the quinolones was quinolones in real cosmetic samples.

  12. Determination of Sudan Residues in Sausage by Matrix Solid-Phase Dispersion and High-Performance Liquid Chromatography.

    Science.gov (United States)

    Zhai, Yujuan; Cheng, Jianhua

    2015-09-01

    A method based on matrix solid-phase dispersion and high-performance liquid chromatography was applied to the determination of four Sudan red residues in sausage. The proposed method required only 0.5 g sample. The neutral alumina was used as the dispersant sorbent while n-hexane containing 10% (v/v) acetone was used as the eluting solvent. The recoveries in samples ranged from 76.4 to 111.0% and relative standard deviations were sausage.

  13. [Determination of congo red in beef by high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry].

    Science.gov (United States)

    Lin, Hui; Xu, Chunxiang; Yan, Chunrong; Zhang, Zheng; Wang, Suilou

    2013-09-01

    A method was developed for the determination of congo red in beef. The analyte was identified by high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry (LC-QTOF MS) and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the congo red in the beef sample was separated on an Agilent ZORBAX Eclipse Plus C18 Rapid Resolution HD UPLC column (50 mm x 2.1 mm, 1.8 microm) HPLC , using 95% (volume percentage) methanol as the mobile phase at 0.2 mL/min. The detection was performed on an AB 4000 + triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The results showed that the linear range of congo red mass concentration was 0.03 - 1 mg/L with the correlation coefficient of 0.999 8. The method had a good precision with the RSDs lower than 5% and the recoveries ranging from 88% to 91%. The limit of detection (LOD) of congo red was 0.01 mg/L. With good reproducibility, the method is simple, fast and effective for the determination of the illegally added congo red in beef and other meat products.

  14. EPA Method 8321B (SW-846): Solvent-Extractable Nonvolatile Compounds by High Performance Liquid Chromatography-Thermospray-Mass Spectrometry (HPLC-TS-MS) or Ultraviolet (UV) Detection

    Science.gov (United States)

    Method 8321B describes procedures for preparation and analysis of solid, aqueous liquid, drinking water and wipe samples using high performance liquid chromatography and mass spectrometry for extractable non-volatile compounds.

  15. Determination of Aspartame, Caffeine, Saccharin, and Benzoic Acid in Beverages by High Performance Liquid Chromatography.

    Science.gov (United States)

    Delaney, Michael F.; And Others

    1985-01-01

    Describes a simple and reliable new quantitative analysis experiment using liquid chromatography for the determinaiton of caffeine, saccharin, and sodium benzoate in beverages. Background information, procedures used, and typical results obtained are provided. (JN)

  16. Advanced Materials and Manufacturing for Low-Cost, High-Performance Liquid Rocket Combustion Chambers Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Silicided niobium alloy (C103) combustion chambers have been used extensively in both NASA and DoD liquid rocket propulsion systems. Niobium alloys offer a good...

  17. Comparative analysis of steroidal saponins in four Dioscoreae herbs by high performance liquid chromatography coupled with mass spectrometry.

    Science.gov (United States)

    Guo, Long; Zeng, Su-Ling; Zhang, Yu; Li, Ping; Liu, E-Hu

    2016-01-01

    Steroidal saponins, which exhibit multiple pharmacological effects, are the major bioactive constituents in herbal medicines from Dioscoreae species. In this study, a sensitive method based on high performance liquid chromatography-mass spectrometry (HPLC-MS) was established and validated for qualitative and quantitative analysis of steroidal saponins in four Dioscoreae herbs including Dioscoreae Nipponica Rhizome (DNR) and Dioscoreae Hypoglaucae Rhizome (DHR), Dioscoreae Spongiosae Rhizome (DSR) and Dioscoreae Rhizome (DR). A total of eleven steroidal saponins were identified by high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (HPLC-QTOF/MS). Furthermore, seven major steroidal saponins was simultaneous quantified using a high performance liquid chromatography coupled with triple quadrupole mass spectrometry (HPLC-QQQ/MS). The qualitative and quantitative analysis results indicated that the chemical composition of DNR, DHR and DSR samples exhibited a high level of global similarity, while the ingredients in DR varied greatly from the other three herbs. Moreover, principal component analysis (PCA) and hierarchical clustering analysis (HCA) were performed to compare and discriminate the Dioscoreae herbs based on the quantitative data. The results demonstrated the qualitative and quantitative analysis of steroidal saponins based on HPLC-MS is a feasible method for quality control of Dioscoreae herbs.

  18. The use of Element-Specific Detectors Coupled with High-Performance Liquid Chromatographs.

    Science.gov (United States)

    1981-11-04

    approach to determining the amount of various chelating agents in solution, Jones and Manahan reacted the indicator metal, A 20 copper(II) with a...latter two cases, GFAA was employed as the element specific detector. Jones and Manahan employing a high performance absorption column directly...Chromatogr. Sci., 17: 395 (1979). 35. D. R. Jones, IV and S. E. Manahan , Anal. Chem., 48: 1897 (1976). 36. D. R. Jones, IV and S. E. Manahan , Anal. Chem

  19. Development and validation of ultra-high performance supercritical fluid chromatography method for determination of illegal dyes and comparison to ultra-high performance liquid chromatography method.

    Science.gov (United States)

    Khalikova, Maria A; Šatínský, Dalibor; Solich, Petr; Nováková, Lucie

    2015-05-18

    A novel simple, fast and efficient ultra-high performance supercritical fluid chromatography (UHPSFC) method was developed and validated for the separation and quantitative determination of eleven illegal dyes in chili-containing spices. The method involved a simple ultrasound-assisted liquid extraction of illegal compounds with tetrahydrofuran. The separation was performed using a supercritical fluid chromatography system and CSH Fluoro-Phenyl stationary phase at 70°C. The mobile phase was carbon dioxide and the mixture of methanol:acetonitrile (1:1, v/v) with 2.5% formic acid as an additive at the flow rate 2.0 mL min(-1). The UV-vis detection was accomplished at 500 nm for seven compounds and at 420 nm for Sudan Orange G, Butter Yellow, Fast Garnet GBC and Methyl Red due to their maximum of absorbance. All eleven compounds were separated in less than 5 min. The method was successfully validated and applied using three commercial samples of chili-containing spices - Chili sauce (Indonesia), Feferony sauce (Slovakia) and Mojo sauce (Spain). The linearity range of proposed method was 0.50-9.09 mg kg(-1) (r ≥ 0.995). The detection limits were determined as signal to noise ratio of 3 and were ranged from 0.15 mg kg(-1) to 0.60 mg kg(-1) (1.80 mg kg(-1) for Fast Garnet) for standard solution and from 0.25 mg kg(-1) to 1.00 mg kg(-1) (2.50 mg kg(-1) for Fast Garnet, 1.50 mg kg(-1) for Sudan Red 7B) for chili-containing samples. The recovery values were in the range of 73.5-107.2% and relative standard deviation ranging from 0.1% to 8.2% for within-day precision and from 0.5% to 8.8% for between-day precision. The method showed potential for being used to monitor forbidden dyes in food constituents. The developed UHPSFC method was compared to the UHPLC-UV method. The orthogonality of Sudan dyes separation by these two methods was demonstrated. Benefits and drawbacks were discussed showing the reliability of both methods for monitoring of studied illegal dyes in real

  20. Development of a high-performance boiling heat exchanger by improved liquid supply to narrow channels.

    Science.gov (United States)

    Ohta, Haruhiko; Ohno, Toshiyuki; Hioki, Fumiaki; Shinmoto, Yasuhisa

    2004-11-01

    A two-phase flow loop is a promising method for application to thermal management systems for large-scale space platforms handling large amounts of energy. Boiling heat transfer reduces the size and weight of cold plates. The transportation of latent heat reduces the mass flow rate of working fluid and pump power. To develop compact heat exchangers for the removal of waste heat from electronic devices with high heat generation density, experiments on a method to increase the critical heat flux for a narrow heated channel between parallel heated and unheated plates were conducted. Fine grooves are machined on the heating surface in a transverse direction to the flow and liquid is supplied underneath flattened bubbles by the capillary pressure difference from auxiliary liquid channels separated by porous metal plates from the main heated channel. The critical heat flux values for the present heated channel structure are more than twice those for a flat surface at gap sizes 2 mm and 0.7 mm. The validity of the present structure with auxiliary liquid channels is confirmed by experiments in which the liquid supply to the grooves is interrupted. The increment in the critical heat flux compared to those for a flat surface takes a maximum value at a certain flow rate of liquid supply to the heated channel. The increment is expected to become larger when the length of the heated channel is increased and/or the gravity level is reduced.

  1. Monosaccharide composition analysis of immunomodulatory polysaccharides by on-line hollow fiber microextraction with high-performance liquid chromatography.

    Science.gov (United States)

    Wang, Nani; Wang, Xuping; Huang, Xiaowen; Mao, Zhujun; Zhang, Yang; Yu, Yong; Shou, Dan

    2016-03-01

    The monosaccharide compositions of functional polysaccharides are essential for structure elucidation and biological activity determination. A sensitive method based on on-line hollow-fiber liquid-phase microextraction with high-performance liquid chromatography has been established for the analysis of ten monosaccharide compositions (two uronic acids, two amino sugars and six neutral sugars) of the immunomodulatory polysaccharides. After derivatization, the sample was injected into the lumen of a hollow fiber immersed in butyl ether and separated by liquid chromatography. Under optimized conditions, the calibration curves were linear (r ≥ 0.9996) in the range of 10-2000 μmol L(-1) . The limits of detection were in the range of 0.04-1.58 μmol L(-1) , and the recoveries were in the range of 92.1-99.6%, which shows that the method is applicable to the analysis of the monosaccharide composition of various polysaccharides.

  2. Preliminary validation of high performance liquid chromatography method for detection of methyl-testosterone residue in carp muscle

    Science.gov (United States)

    Jiang, Jie; Lin, Hong; Fu, Xiaoting; Li, Mingming

    2005-07-01

    The use of synthetic anabolic steroid methyltestosterone (MT) as growth promoter is prohibited in China. Validations of analytical methods for MT residue in food and the results obtained have become indispensable. The high performance liquid chromatography (HPLC) method for the detection of MT with liquid-liquid extraction by trichloromethane-methanol in carp muscle tissue was preliminarily validated with reference to the following parameters: recovery (accuracy) at the 1, 5 and l0 mgkg-1 level, between-run and within-run CV values (repeatability, also called relative standard deviation (RSD)) and limit of detection. The recoveries were above 80% and the between-run and within-run CV values below 10% for muscle tissue. The limit of detection was 0.05 mgkg-1.

  3. Quantitative separation of tetralin hydroperoxide from its decomposition products by high performance liquid chromatography

    Science.gov (United States)

    Worstell, J. H.; Daniel, S. R.

    1981-01-01

    A method for the separation and analysis of tetralin hydroperoxide and its decomposition products by high pressure liquid chromatography has been developed. Elution with a single, mixed solvent from a micron-Porasil column was employed. Constant response factors (internal standard method) over large concentration ranges and reproducible retention parameters are reported.

  4. High Performance Liquid Chromatography of Some Analgesic Compounds: An Instrumental Analysis Experiment.

    Science.gov (United States)

    Haddad, Paul; And Others

    1983-01-01

    Background information, procedures, and results are provided for an experiment demonstrating techniques of solvent selection, gradient elution, pH control, and ion-pairing in the analysis of an analgesic mixture using reversed-phase liquid chromatography on an octadecylsilane column. Although developed using sophisticated/expensive equipment, less…

  5. Validated Stability-indicating High-performance Liquid Chromatographic Method for Estimation of Degradation Behaviour of Eberconazole Nitrate and Mometasone Furoate in Cream Formulation

    OpenAIRE

    Sharma, N.; Rao, S. S.; Vaghela, B

    2013-01-01

    The objective of current investigation was to study the degradation behaviour of eberconazole nitrate and mometasone furoate under different International Conference on harmonisation recommended stress condition using reverse phase high performance liquid chromatographic method and to establish validated stability-indicating high performance liquid chromatographic method to determine purity of eberconazole nitrate and mometasone furoate in presence of its impurities, forced degradation produc...

  6. Dispersive liquid-liquid microextraction based on solidification of floating organic droplets followed by high performance liquid chromatography for the determination of duloxetine in human plasma.

    Science.gov (United States)

    Suh, Joon Hyuk; Lee, Yun Young; Lee, Hee Joo; Kang, Myunghee; Hur, Yeoun; Lee, Sun Neo; Yang, Dong-Hyug; Han, Sang Beom

    2013-03-05

    A novel dispersive liquid-liquid microextraction method based on solidification of floating organic droplets (DLLME-SFO) technique was developed for the determination of duloxetine in human plasma samples by high performance liquid chromatography with fluorescence detection (HPLC-FLD). During the extraction procedure, plasma protein was precipitated by using a mixture of zinc sulfate solution and acetonitrile. After the protein precipitation step, duloxetine in an alkaline sample solution was quickly extracted by DLLME-SFO with 50 μL of 1-undecanol (extractant). Disperser was unnecessary because the small amount of remaining acetonitrile, which acts as a protein precipitating reagent, was also employed as a disperser; therefore, organic solvent consumption was reduced as much as possible. The emulsion was centrifuged and then fine droplets were floated to the top of the sample solution. The floated droplets were solidified in an ice bath and easily transferred. Various DLLME-SFO parameters such as extractant type, extractant amount, ionic strength, pH and extraction time were optimized. The chromatographic separation of duloxetine was carried out using ethanol as mobile phase. Validation of the method was performed with respect to linearity, intra- and inter-day accuracy and precision, limit of quantification (LOQ), and recovery. Calibration curves for duloxetine showed good linearity with correlation coefficients (r²) higher than 0.99. The method showed good precision and accuracy, with intra- and inter-assay coefficients of variation less than 15% (LOQ: less than 20%) at all concentrations. The recovery was carried out following the standard addition procedure with yields ranging from 59.6 to 65.5%. A newly developed environmentally friendly method was successfully applied to the pharmacokinetic study of duloxetine in human plasma and was shown to be an alternative green approach compared with the conventional solid-phase microextraction (SPME) and dispersive

  7. Ionic liquid foam floatation coupled with ionic liquid dispersive liquid-liquid microextraction for the separation and determination of estrogens in water samples by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Zhang, Rui; Wang, Chuanliu; Yue, Qiaohong; Zhou, Tiecheng; Li, Na; Zhang, Hanqi; Hao, Xiaoke

    2014-11-01

    An ionic liquid foam floatation coupled with ionic liquid dispersive liquid-liquid microextraction method was proposed for the extraction and concentration of 17-α-estradiol, 17-β-estradiol-benzoate, and quinestrol in environmental water samples by high-performance liquid chromatography with fluorescence detection. 1-Hexyl-3-methylimidazolium tetrafluoroborate was applied as foaming agent in the foam flotation process and dispersive solvent in microextraction. The introduction of the ion-pairing and salting-out agent NH4 PF6 was beneficial to the improvement of recoveries for the hydrophobic ionic liquid phase and analytes. Parameters of the proposed method including concentration of 1-hexyl-3-methylimidazolium tetrafluoroborate, flow rate of carrier gas, floatation time, types and concentration of ionic liquids, salt concentration in samples, extraction time, and centrifugation time were evaluated. The recoveries were between 98 and 105% with relative standard deviations lower than 7% for lake water and well water samples. The isolation of the target compounds from the water was found to be efficient, and the enrichment factors ranged from 4445 to 4632. This developing method is free of volatile organic solvents compared with regular extraction. Based on the unique properties of ionic liquids, the application of foam floatation, and dispersive liquid-liquid microextraction was widened.

  8. Pipette vial dispersive liquid-liquid microextraction combined with high-performance liquid chromatography for the determination of benzoylurea insecticide in fruit juice.

    Science.gov (United States)

    Xi, Xuefei; Yang, Miyi; Shen, Ganni; Wu, Xiaoling; Lu, Runhua; Zhou, Wenfeng; Zhang, Sanbing; Gao, Haixiang

    2016-01-01

    A simple, sensitive, and efficient method of using a pipette vial to perform dispersive liquid-liquid microextraction based on the solidification of floating organic droplets was coupled with high-performance liquid chromatography (HPLC) and a diode array detector for the preconcentration and analysis of four benzoylurea insecticides in fruit juice. In this method, 1-dodecanol was used as an extractant, and a snipped pipette was used as an experimental vial to simplify the procedure of collecting and separating solidified extractant. The experimental parameters were optimized using a Plackett-Burman design and one-factor-at-a-time method. Under the optimal conditions in the water model, the limits of detection for analytes varied from 0.03 to 0.28 μg/L, and the enrichment factors ranged from 147 to 206. Linearity was achieved for diflubenzuron and flufenoxuron in a range of 0.5-500 μg/L, for hexaflumuron in a range of 1-500 μg/L, and for triflumuron in a range of 5-500 μg/L. The correlation coefficients for the analytes ranged from 0.9986 to 0.9994 with recoveries of 91.4-110.9%. Finally, the developed technique was successfully applied to fruit juice samples with acceptable results. The relative standard deviations of the analytes at two spiking levels (50 and 200 μg/L) varied between 0.2 and 4.5%.

  9. Sensitive determination of melamine in milk and powdered infant formula samples by high-performance liquid chromatography using dabsyl chloride derivatization followed by dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Faraji, M; Adeli, M

    2017-04-15

    A new and sensitive pre-column derivatization with dabsyl chloride followed by dispersive liquid-liquid microextraction was developed for the analysis of melamine (MEL) in raw milk and powdered infant formula samples by high performance liquid chromatography (HPLC) with visible detection. Derivatization with dabsyl chloride leads to improving sensitivity and hydrophobicity of MEL. Under optimum conditions of derivatization and microextraction steps, the method yielded a linear calibration curve ranging from 1.0 to 500μgL(-1) with a determination coefficient (R(2)) of 0.9995. Limit of detection and limit of quantification were 0.1 and 0.3μgL(-1), respectively. The relative standard deviation (RSD%) for intra-day (repeatability) and inter-day (reproducibility) at 25 and 100μgL(-1) levels of MEL was less than 7.0% (n=6). Finally, the proposed method was successfully applied for the preconcentration and determination of MEL in different raw milk and powdered infant formula, and satisfactory results were obtained (relative recovery ⩾94%).

  10. Ion pair-based dispersive liquid-liquid microextraction followed by high performance liquid chromatography as a new method for determining five folate derivatives in foodstuffs.

    Science.gov (United States)

    Nojavan, Yones; Kamankesh, Marzieh; Shahraz, Farzaneh; Hashemi, Maryam; Mohammadi, Abdorreza

    2015-05-01

    A novel technique for simultaneous determination of five folate derivatives in various food matrices was developed by ion pair-based dispersive liquid-liquid microextraction (IP-DLLME) combined with high-performance liquid chromatography (HPLC). In the proposed method, N-methyl-N,N-dioctyloctan-1-ammonium chloride (aliquat-336) was used as an ion-pair reagent. Effective variables of microextraction process were optimized. Under optimum conditions, the method yielded a linear calibration curve ranging from 1-200 ng g(-1) with correlation coefficients (r(2)) higher than 0.98. The relative standard deviation for the seven analyses was 5.2-7.4%. Enrichment factors for the five folates ranged between 108-135. Limits of detection were 2-4.1 ng g(-1). A comparison of this method with other methods described that the new proposed method is rapid and accurate, and gives very good enrichment factors and detection limits for determining five folate derivatives. The newly developed method was successfully applied for the determination of five folate derivatives in wheat flour, egg yolk and orange juice samples.

  11. Intravascular Residence Time Determination for the Cyanide Antidote Dimethyl Trisulfide in Rat by Using Liquid-Liquid Extraction Coupled with High Performance Liquid Chromatography

    Science.gov (United States)

    De Silva, Deepthika; Lee, Steven; Duke, Anna; Angalakurthi, Siva; Chou, Ching-En; Ebrahimpour, Afshin; Thompson, David E.

    2016-01-01

    These studies represent the first report on the intravascular residence time determinations for the cyanide antidote dimethyl trisulfide (DMTS) in a rat model by using high performance liquid chromatography coupled with ultraviolet absorption spectroscopy (HPLC-UV). The newly developed sample preparation included liquid-liquid extraction by cyclohexanone. The calibration curves showed a linear response for DMTS concentrations between 0.010 and 0.30 mg/mL with R2 = 0.9994. The limit of detection for DMTS via this extraction method was 0.010 mg/mL, and the limit of quantitation was 0.034 mg/mL. Thus this calibration curve provided a tool for determining DMTS in the range between 0.04 and 0.30 mg/mL. Rats were given 20 mg/kg DMTS dose (in 15% Polysorbate 80) intravenously, and blood samples were taken 15, 60, 90, 120, and 240 min after DMTS injections. The data points were plotted as DMTS concentration in RBCs versus time, and the intravascular residence time was determined graphically. The results indicated a half-life of 36 min in a rat model, suggesting that the circulation time is long enough to provide a reasonable time interval for cyanide antagonism. PMID:28053802

  12. Automated dispersive liquid-liquid microextraction coupled to high performance liquid chromatography - cold vapour atomic fluorescence spectroscopy for the determination of mercury species in natural water samples.

    Science.gov (United States)

    Liu, Yao-Min; Zhang, Feng-Ping; Jiao, Bao-Yu; Rao, Jin-Yu; Leng, Geng

    2017-04-14

    An automated, home-constructed, and low cost dispersive liquid-liquid microextraction (DLLME) device that directly coupled to a high performance liquid chromatography (HPLC) - cold vapour atomic fluorescence spectroscopy (CVAFS) system was designed and developed for the determination of trace concentrations of methylmercury (MeHg(+)), ethylmercury (EtHg(+)) and inorganic mercury (Hg(2+)) in natural waters. With a simple, miniaturized and efficient automated DLLME system, nanogram amounts of these mercury species were extracted from natural water samples and injected into a hyphenated HPLC-CVAFS for quantification. The complete analytical procedure, including chelation, extraction, phase separation, collection and injection of the extracts, as well as HPLC-CVAFS quantification, was automated. Key parameters, such as the type and volume of the chelation, extraction and dispersive solvent, aspiration speed, sample pH, salt effect and matrix effect, were thoroughly investigated. Under the optimum conditions, linear range was 10-1200ngL(-1) for EtHg(+) and 5-450ngL(-1) for MeHg(+) and Hg(2+). Limits of detection were 3.0ngL(-1) for EtHg(+) and 1.5ngL(-1) for MeHg(+) and Hg(2+). Reproducibility and recoveries were assessed by spiking three natural water samples with different Hg concentrations, giving recoveries from 88.4-96.1%, and relative standard deviations <5.1%.

  13. Vortex-assisted low density solvent based demulsified dispersive liquid-liquid microextraction and high-performance liquid chromatography for the determination of organophosphorus pesticides in water samples.

    Science.gov (United States)

    Seebunrueng, Ketsarin; Santaladchaiyakit, Yanawath; Srijaranai, Supalax

    2014-05-01

    A simple, rapid, effective and eco-friendly preconcentration method, vortex-assisted low density solvent based solvent demulsified dispersive liquid-liquid microextraction (VLDS-SD-DLLME), followed by high performance liquid chromatography-diode array detector (HPLC-DAD) analysis, has been developed for the first time for the determination of four organophosphorus pesticides (OPPs) (e.g., azinphos-methyl, parathion-methyl, fenitrothion and diazinon) in environmental water samples. In this preconcentration procedure, an emulsion was obtained after the mixture of extraction solvent (1-dodecanol) and dispersive solvent (acetonitrile, ACN) was injected rapidly into 10 mL of the sample solution. The vortex agitator aided the dispersion of the extraction solvent into the sample solution. After the formation of an emulsion, the demulsifier (ACN) was added, resulting in the rapid separation of the mixture into two phases without centrifugation. Under optimal conditions, the proposed method provided high extraction efficiency (90-99%), good linearity range (0.5-500 ng mL(-1)), low limits of detection (0.25-1 ng mL(-1)) and good repeatability and recoveries were obtained.

  14. Combination of saponification and dispersive liquid-liquid microextraction for the determination of tocopherols and tocotrienols in cereals by reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Shammugasamy, Balakrishnan; Ramakrishnan, Yogeshini; Ghazali, Hasanah M; Muhammad, Kharidah

    2013-07-26

    A simple sample preparation technique coupled with reversed-phase high-performance liquid chromatography was developed for the determination of tocopherols and tocotrienols in cereals. The sample preparation procedure involved a small-scale hydrolysis of 0.5g cereal sample by saponification, followed by the extraction and concentration of tocopherols and tocotrienols from saponified extract using dispersive liquid-liquid microextraction (DLLME). Parameters affecting the DLLME performance were optimized to achieve the highest extraction efficiency and the performance of the developed DLLME method was evaluated. Good linearity was observed over the range assayed (0.031-4.0μg/mL) with regression coefficients greater than 0.9989 for all tocopherols and tocotrienols. Limits of detection and enrichment factors ranged from 0.01 to 0.11μg/mL and 50 to 73, respectively. Intra- and inter-day precision were lower than 8.9% and the recoveries were around 85.5-116.6% for all tocopherols and tocotrienols. The developed DLLME method was successfully applied to cereals: rice, barley, oat, wheat, corn and millet. This new sample preparation approach represents an inexpensive, rapid, simple and precise sample cleanup and concentration method for the determination of tocopherols and tocotrienols in cereals.

  15. Rapid extraction and determination of amphetamines in human urine samples using dispersive liquid-liquid microextraction and solidification of floating organic drop followed by high performance liquid chromatography.

    Science.gov (United States)

    Ahmadi-Jouibari, Toraj; Fattahi, Nazir; Shamsipur, Mojtaba

    2014-06-01

    A novel, rapid, simple and sensitive dispersive liquid-liquid microextraction method based on the solidification of floating organic drop (DLLME-SFO) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine amphetamine and methamphetamine in urine samples. The factors affecting the extraction efficiency of DLLME-SFO such as the kind and volume of the extraction and the disperser solvents, effect of concentration of K2CO3 and extraction time were investigated and the optimal extraction conditions were established. Under the optimum conditions (extraction solvent: 30.0μl 1-undecanol; disperser solvent: 300μl acetonitrile; buffer concentration: 2% (w/v) K2CO3 and extraction time: 1min), calibration curves are linear in the range of 10-3000μgl(-1) and limit of detections (LODs) are in the range of 2-8μgl(-1). The relative standard deviations (RSDs) for 100μgl(-1) of amphetamine and methamphetamine in diluted urine are in the range of 6.2-7.8% (n=7). The method was successfully applied for the determination of amphetamine and methamphetamine in the actual urine samples. The relative recoveries of urine samples spiked with amphetamine and methamphetamine are 87.8-113.2%. The obtained results show that DLLME-SFO combined with HPLC-UV is a fast and simple method for the determination of amphetamine and methamphetamine in urine.

  16. Novel method for the determination of five carbamate pesticides in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    Zhi Mei Liu; Xiao Huan Zang; Wei Hua Liu; Chun Wang; Zhi Wang

    2009-01-01

    A novel method for the determination of five carbamate pesticides(metolcarb,carbofuran,carbaryl,isoprocard and diethofencard)in water samples was developed by dispersive liquid-liquid microextraction(DLLME)coupled with high performance liquid chromatography-diode array detector(HPLC-DAD).Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results.Under the optimum conditions for the method,the calibration curve was linear in the concentration range from 5 to I000 ng mL-1 for all the five carbamate pesticides,with the correlation coefficients(r2)varying from 0.9984 to 0.9994.Good enrichment factors were achieved ranging from 80 to 177-fold,depending on the compound.The limits of detection(LODs)(S/N = 3)were ranged from 0.1 to 0.5 ng mL-1.The method has been successfully applied to the analysis of the pesticide residues in environmental water samples.

  17. Intravascular Residence Time Determination for the Cyanide Antidote Dimethyl Trisulfide in Rat by Using Liquid-Liquid Extraction Coupled with High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Deepthika De Silva

    2016-01-01

    Full Text Available These studies represent the first report on the intravascular residence time determinations for the cyanide antidote dimethyl trisulfide (DMTS in a rat model by using high performance liquid chromatography coupled with ultraviolet absorption spectroscopy (HPLC-UV. The newly developed sample preparation included liquid-liquid extraction by cyclohexanone. The calibration curves showed a linear response for DMTS concentrations between 0.010 and 0.30 mg/mL with R2 = 0.9994. The limit of detection for DMTS via this extraction method was 0.010 mg/mL, and the limit of quantitation was 0.034 mg/mL. Thus this calibration curve provided a tool for determining DMTS in the range between 0.04 and 0.30 mg/mL. Rats were given 20 mg/kg DMTS dose (in 15% Polysorbate 80 intravenously, and blood samples were taken 15, 60, 90, 120, and 240 min after DMTS injections. The data points were plotted as DMTS concentration in RBCs versus time, and the intravascular residence time was determined graphically. The results indicated a half-life of 36 min in a rat model, suggesting that the circulation time is long enough to provide a reasonable time interval for cyanide antagonism.

  18. Simultaneous determination of six synthetic phenolic antioxidants in edible oils using dispersive liquid-liquid microextraction followed by high-performance liquid chromatography with diode array detection.

    Science.gov (United States)

    Xu, Shuangjiao; Liu, Liangliang; Wang, Yanqin; Zhou, Dayun; Kuang, Meng; Fang, Dan; Yang, Weihua; Wei, Shoujun; Xiao, Aiping; Ma, Lei

    2016-08-01

    A simple, rapid, organic-solvent- and sample-saving pretreatment technique, called dispersive liquid-liquid microextraction, was developed for the determination of six synthetic phenolic antioxidants from edible oils before high-performance liquid chromatography with diode array detection. The entire procedure was composed of a two-step microextraction and a centrifugal process and could be finished in about 5 min, only consuming only 25 mg of sample and 1 mL of the organic solvent for each extraction. The influences of several important parameters on the microextraction efficiency were thoroughly investigated. Recovery assays for oil samples were spiked at three concentration levels, 50, 100 and 200 mg/kg, and provided recoveries in the 86.3-102.5% range with a relative standard deviation below 3.5%. The intra-day and inter-day precisions for the analysis were less than 3.8%. The proposed method was successfully applied for the determination of synthetic phenolic antioxidants in different oil samples, and satisfactory results were obtained. Thus, the developed method represents a viable alternative for the quality control of synthetic phenolic antioxidant concentrations in edible oils.

  19. Determination of six pyrethroid insecticides in fruit juice samples using dispersive liquid-liquid microextraction combined with high performance liquid chromatography.

    Science.gov (United States)

    Boonchiangma, Suthasinee; Ngeontae, Wittaya; Srijaranai, Supalax

    2012-01-15

    Dispersive liquid-liquid microextraction (DLLME) coupled to high performance liquid chromatography (HPLC) with UV detection was applied for the determination of six pyrethroids (tetramethrin, fenpropathrin, cypermethrin, deltamethrin, fenvalerate and permethrin) in various fruit juices including apple, red grape, orange, kiwi, passion fruit, pomegranate and guava juice. Six pyrethroids were separated within 30 min using a Waters Atlantis T3 column under an isocratic elution of acetonitrile-water (72:28). The parameters affecting extraction efficiency of the DLLME method such as type of disperser and extraction solvent, volume of disperser and extraction solvent and centrifugation time were investigated. Under the optimum conditions, 5.00 mL of sample solution, 300 μL of chloroform as extraction solvent and 1.25 mL of methanol as dispersive solvent gave high enrichment factor in the range of 62-84. Good linearity was obtained from 2 to 1,500 μg/L (r(2)>0.995). The mean recoveries of the pyrethroids evaluated by fortification of real samples were in the range of 84-94%. The limits of detection ranging from 2 to 5 μg/L are sufficient to analyze pyrethroid residues at the maximum residue limits (MRLs) established by the European Union (EU) in fruit juices. The proposed method can be applied to direct determination of pyrethroid residues in fruit juices.

  20. Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-diode array detection as an efficient and sensitive technique for determination of antioxidants.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Bahram, Morteza; Jönsson, Jan Ake

    2007-05-15

    Dispersive liquid-liquid microextraction (DLLME) and high performance liquid chromatography-diode array detection (HPLC-DAD) was presented for extraction and determination of Irganox 1010, Irganox 1076 and Irgafos 168 (antioxidants) in aqueous samples. Carbon tetrachloride at microliter volume level and acetonitrile were used as extraction and dispersive solvents, respectively. The main advantages of method are high speed, high enrichment factor, high recovery, good repeatability and extraction solvent volume at microL level. Limit of detection for analytes is between 3 and 7 ng mL(-1). One variable at a time optimization and response surface modeling were used to obtain optimum conditions for microextraction procedure and nearly same experimental conditions were obtained using both optimization methods. Recoveries in the ranges 78-86% and 84-110% were obtained by one variable at a time and response surface modeling, respectively. Using tap water and packed water as matrices do not show any detrimental effect on the extraction recoveries and enrichment factors of analytes.

  1. Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography for determination of benzoate and sorbate in yogurt drinks and method optimization by central composite design.

    Science.gov (United States)

    Kamankesh, Marzieh; Mohammadi, Abdorreza; Tehrani, Zohreh Modarres; Ferdowsi, Roohallah; Hosseini, Hedayat

    2013-05-15

    A new method based on dispersive liquid-liquid microextraction (DLLME) followed by high-performance liquid chromatography (HPLC) for determination of benzoate and sorbate salts in yogurt drinks was developed. The effective parameters in DLLME process, including volume of extraction and disperser solvents, pH and salt effect, were optimized using response surface methodology (RSM) based on central composite design. The yogurt drink samples were extracted using NaOH and Carrez solutions (potassium hexaferrocyanide and zinc acetate) were used for sedimentation of proteins. For DLLME, a mixture of extraction solvent (1-octanol) and disperser solvent (ethanol) was rapidly injected into the sample solution by syringe and cloudy solution is formed. Subsequently, the upper 1-octanol layer was analyzed by HPLC. The detection limits for benzoate and sorbate were 0.06 ng mL(-1) and 0.15 ng mL(-1), respectively. The relative standard deviations (RSD) for seven analyses were 4.96% for benzoate and 4.58% for sorbate. The proposed method demonstrated good linearity and high enrichment factor. A clean separation and good chromatogram is readily achieved without the presence of matrix interference. A comparison of this method with previous methods demonstrated that the proposed method is an accurate, rapid and reliable sample-pretreatment method that gives very good enrichment factors and detection limits for extracting and determining sorbate and benzoate in yogurt drink samples.

  2. Sensitive high-performance liquid chromatographic quantitation of gabapentin in human serum using liquid-liquid extraction and pre-column derivatization with 9-fluorenylmethyl chloroformate.

    Science.gov (United States)

    Bahrami, Gholamreza; Kiani, Amir

    2006-05-01

    Most of the published methods for analysis of gabapentin, an antiepileptic agent, in human serum are based on the same approach, involving o-phthaldialdehyde derivatization of deproteinized serum samples. The present paper however, describes a new, simple and sensitive high-performance liquid chromatographic method for determination of gabapentin in human serum using liquid-liquid extraction and 9-fluorenylmethyl chloroformate (FMOC-Cl) as pre-column labeling agent. The drug and an internal standard (azithromycin) were extracted from serum by salting-out approach using a mixture of dichloromethane-2 propanol (1:1, v/v) as the extracting solvent. The extracted analytes were subjected to derivatization with FMOC-Cl in the presence of phosphate buffer (pH 7). A mobile phase consisting of methanol-0.05 M sodium phosphate buffer (73/27, v/v; pH of 3.9) containing 1 ml/l triethylamine was eluted and chromatographic separation was performed on a Shimpack CLC-C18 (150 mm x 4.6 mm) column. The standard curve was linear over the range of 0.03-20 microg/ml and limit of quantification was 0.03 microg/ml. The performance of analysis was studied and the validated method showed excellent performance in terms of selectivity, specificity, sensitivity, precision and accuracy. No interferences were found from commonly co-administered antiepileptic agents.

  3. Determination of furanochromones and pyranocoumarins in drugs and Ammi visnaga fruits by combined solid-phase extraction-high-performance liquid chromatography and thin-layer chromatography-high-performance liquid chromatography.

    Science.gov (United States)

    Zgórka, G; Dragan, T; Głowniak, K; Basiura, E

    1998-02-27

    A new, simple and rapid solid-phase extraction method for the determination of furanochromones and pyranocoumarins in Ammi visnaga L. fruits and pharmaceuticals by reversed-phase high-performance liquid chromatography (RP-HPLC) was developed. The isolation of compounds examined was carried out on octadecyl BakerBond SPE columns using various concentrations of methanol, acetonitrile and tetrahydrofuran in water. High and reproducible recoveries were obtained. To compare the results of quantitative analysis a preparative TLC procedure was also elaborated and carried out.

  4. Highly efficient peptide separations in proteomics Part 1. Unidimensional high performance liquid chromatography.

    Science.gov (United States)

    Sandra, Koen; Moshir, Mahan; D'hondt, Filip; Verleysen, Katleen; Kas, Koen; Sandra, Pat

    2008-04-15

    Sample complexity and dynamic range constitute enormous challenges in proteome analysis. The back-end technology in typical proteomics platforms, namely mass spectrometry (MS), can only tolerate a certain complexity, has a limited dynamic range per spectrum and is very sensitive towards ion suppression. Therefore, component overlap has to be minimized for successful mass spectrometric analysis and subsequent protein identification and quantification. The present review describes the advances that have been made in liquid-based separation techniques with focus on the recent developments to boost the resolving power. The review is divided in two parts; the first part deals with unidimensional liquid chromatography and the second part with bi- and multidimensional liquid-based separation techniques. Part 1 mainly focuses on reversed-phase HPLC due to the fact that it is and will, in the near future, remain the technique of choice to be hyphenated with MS. The impact of increasing the column length, decreasing the particle diameter, replacing the traditional packed beds by monolithics, amongst others, is described. The review is complemented with data obtained in the laboratories of the authors.

  5. Identification, characterization, and high-performance liquid chromatography quantification of process-related impurities in vonoprazan fumarate.

    Science.gov (United States)

    Liu, Lei; Cao, Na; Ma, Xingling; Xiong, Kaihe; Sun, Lili; Zou, Qiaogen

    2016-04-01

    High-performance liquid chromatography analysis of vonoprazan fumarate, a novel proton pump inhibitor drug revealed six impurities. These were identified by liquid chromatography with mass spectrometry. Further, the structures of the impurities were confirmed by synthesis followed by characterization by mass spectrometry, NMR spectroscopy, and infrared spectroscopy. On the basis of these data and knowledge of the synthetic scheme of vonoprazan fumarate, the previously unknown impurity was identified as 1-[5-(2-fluorophenyl)-1-(pyridin-3-ylsulfonyl)-1H-pyrrol-3-yl]-N-methyldimethylamine, which is a new compound. The possible mechanisms by which these impurities were formed were also discussed. A high-performance liquid chromatography method was optimized in order to separate, selectively detect, and quantify all process-related impurities of vonoprazan fumarate. The presented method has been validated in terms of linearity, limits of detection, and quantification, and response factors and, therefore, is highly suitable for routine analysis of vonoprazan fumarate related substances as well as stability studies.

  6. Determination of total phthalates in edible oils by high-performance liquid chromatography coupled with photodiode array detection.

    Science.gov (United States)

    Xie, Qilong; Sun, Dekui; Han, Yangying; Jia, Litao; Hou, Bo; Liu, Shuhui; Li, Debao

    2016-03-01

    The previously reported procedure for the determination of the total phthalate in fatty food involved the extraction of phthalates using chloroform/methanol followed by the removal of the solvents before alkaline hydrolysis requiring 20 h and derivatization of phthalic acid. In this study, a phase-transfer catalyst (tetrabutylammonium chloride) was used in the liquid-liquid heterogeneous hydrolysis of phthalates in oil matrix shortening the reaction time to within 25 min. The resulting phthalic acid in the hydrolysate was extracted by a novel molecular complex based dispersive liquid-liquid microextraction method coupled with back-extraction before high-performance liquid chromatography coupled with photodiode array detection. Under the optimal experimental conditions, the linearity of the method was in the range of 0.5-12 nmol/g with the correlation coefficients (r) >0.997. The detection limit (S/N = 3) was 0.11 nmol/g. Intraday and interday repeatability values expressed as relative standard deviation were 3.9 and 7.1%, respectively. The recovery rates ranged from 82.4 to 99.0%. The developed method was successfully applied for the analysis of total phthalate in seven edible oils.

  7. DETERMINATION OF GAMMA - AMINOBUTYRIC ACID BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    D. Qujeq

    1998-08-01

    Full Text Available Gamma-aminobutyric acid is the main inhibitory amino acid neurotransmitter in several areas of the brain. Measurement of gamma-aminobutyric acid in the brain will help elucidate its metabolic rote and diagnostic value. The liquid chromatography (LC system consisted of a delivery pump. Male rats (150-250g were used in this study. The brain was rapidly removed from decapitated animals. Trie chromatograms showed satisfactory resolution and symmetrical peak shapes, both with the standard and tissue extracts. the retention lime was 4.60 min. it was constant in repeated analyses and exactly the same for the standard and tissue samples.

  8. Validation of a technique by high-performance liquid chromatography for the determination of total isoflavones

    Directory of Open Access Journals (Sweden)

    Pilar A. Soledispa Cañarte

    2017-04-01

    Full Text Available Context: Isoflavones may act as selective regulators in the prevention of various diseases. The most important source of isoflavones is the soy, from which different phytotherapeutics are elaborated of use in Ecuadorian population. However, its concentration varies depending on several factors, therefore quality assessment need to be carried out through out several analytical methods. Aims: To validate an analytical method by high precision liquid chromatography (HPLC to quantify total isoflavones in herbal medicine. Methods: To quantify isoflavones, it was used a brand liquid chromatography with UV/VIS detector at 260 nm, C-18 column using isocratic method. The mobile phase was composed of 2% acetic acid: acetonitrile (75:25. The quantification was performed against reference standard. The parameters for the validation followed the established in the USP 33. Results: The chromatogram presented six peaks with elution between 1.557 and 18.913 min. The linearity of the system and the method got r2 equal to 0.98 and 0.99 respectively. The coefficients of variation 1.5% in the study of repetitiveness and 2% in intermediate precision. The accuracy of the adjusted lineal model exhibited r=0.95 and intercept reliable interval (-0.921; 1.743. Conclusions: The validated method was specific, accurate, precise and linear. It can be used for quality control and stability studies of isoflavones present in herbal medicine.

  9. High performance red phosphorus electrode in ionic liquid-based electrolyte for Na-ion batteries

    Science.gov (United States)

    Dahbi, Mouad; Fukunishi, Mika; Horiba, Tatsuo; Yabuuchi, Naoaki; Yasuno, Satoshi; Komaba, Shinichi

    2017-09-01

    Electrochemical performance of the red phosphorus electrode was examined in ionic-liquid electrolyte, 0.25 mol dm-3 sodium bisfluorosulfonylamide (NaFSA) dissolved N-methyl-N-propylpyridinium-bisfluorosulfonylamide (MPPFSA), at room temperature. We compared its electrochemical performance to conventional EC/PC/DEC, EC/DEC, and PC solutions containing 1 mol dm-3 NaPF6. The electrode in NaFSA/MPPFSA demonstrated a reversible capacity of 1480 mAh g-1 and excellent capacity retention of 93% over 80 cycles, which is much better than those in the conventional electrolytes. The difference in capacity retention for the electrolytes correlates to the different solid electrolyte interphase (SEI) layer formed on the phosphorus electrode. To understand the SEI formation in NaFSA/MPPFSA and its evolution during cycling, we investigate the surface layer of the red phosphorus electrodes with hard X-ray photoelectron spectroscopy (HAXPES) and time-of-flight secondary ion mass spectrometry (TOF-SIMS). A detailed analysis of HAXPES spectra demonstrates that SEI layer consists of major inorganic and minor organic species, originating from decomposition of MPP+ and FSA-. Homogenous surface layer is formed during the first cycle in NaFSA/MPPFSA while in alkyl carbonate ester electrolytes, continuous growth of surface film up to the 20th cycle is observed. Possibility of red phosphorous electrode for battery applications with pure ionic liquid is discussed.

  10. Synthesis of novel glucose-based polymers and their applications as chiral stationary phases for high performance liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    Tomoyuki IKAI; Takayuki YAMADA

    2016-01-01

    Two novel polymers containing glucose units as the main-chain that only differ in terms of their regioregularity were synthesized to evaluate their chiral recognition abilities as chiral stationary phases( CSPs) for high performance liquid chromatography( HPLC). The regioregular polymer( poly-5)shows clear resolution ability for the racemate of cobalt(Ⅲ)acetylacetonate( Co( acac)3 ),whereas the corresponding regioirregular polymer(poly-3)does not show any chiral recognition for Co(acac)3. The regioregular polymer main-chain seems to play an important role not only in providing an efficient interaction with the racemate but also in expressing the chiral recognition ability as a CSP for HPLC.

  11. Simultaneous High Performance Liquid Chromatography Assay of Pentoxifylline, Mupirocin, Itraconazole, and Fluticasone Propionate in Humco™ Lavare Wound Base

    Directory of Open Access Journals (Sweden)

    Troy Purvis

    2015-11-01

    Full Text Available This article details the elements used in the method verification for the simultaneous high performance liquid chromatography (HPLC assay of Pentoxifylline, Mupirocin, Itraconazole, and Fluticasone Propionate in Humco™ Lavare Wound base. The method was proven to be linear over 50%–150% of the nominal concentration of the standards. The method was proven to be accurate over 50%–150%, with 98%–102% recovery of the actives from spiked placeboes over that range. The method was shown to be specific to the analytes listed and precise, yielding acceptable results for system reproducibility and method repeatability. The method, as written, is considered to have been verified.

  12. High Performance Liquid Chromatography of Propellants. Part 1. Analysis of M1, M6, and M10 Propellants

    Science.gov (United States)

    1986-05-01

    High performance liquid chromatography permits the differentation among the stabilizers and their degradation products together with accurate quantitation. This progress report describes work carried out in the analysis of single base propellants containing diphenylamine (DPA) as the stabilizer. Several degradation products have been identified and the routine determination of these compounds is feasible. The degradation of DPA seems to follow a pattern that is unique for M1 and M6’s as compared to the pattern for M10’s. It is postulated

  13. Separation of Long and Short Chain Fatty Acids as Naphthacyl and Substituted Phenacyl Esters by High Performance Liquid Chromatography.

    Science.gov (United States)

    High performance liquid chromatography of various C2 - C24 fatty acids was run on their p-bromophenacyl, p-nitrophenacyl, p-chlorophenacyl, and 2--naphthacyl esters. All the separations were accomplished using reversed phase columns with the eluent consisting of an acetonitrile:water gradient. For all derivatives tested the separations were well defined and analogous although certain esters eluted together as one peak. Quantitative results indicate that the limit of detection in the present study was two picograms of n-caproic acid and 10 picograms of

  14. Determination of CYP4A11-catalyzed lauric acid 12-hydroxylation by high-performance liquid chromatography with radiometric detection.

    Science.gov (United States)

    Crespi, Charles L; Chang, Thomas K H; Waxman, David J

    2006-01-01

    Lauric acid serves as an endogenous substrate for the cytochrome P450 enzyme CYP4A11. A reverse-phase, high-performance liquid chromatography method is described for the quantification of 12-hydroxylauric acid formed enzymatically by incubation of 14C-labeled lauric acid with cDNA-expressed CYP4A11 or human liver microsomes. Analytical separation is achieved using a C18 column and a gradient of 30% acetonitrile and 2 mM perchloric acid to 100% methanol, using a detection scintillation counter. This method is applicable to enzymatic studies for determination of lauric acid 12-hydroxylation activity.

  15. Identification of Ceftiofur Oxidation Products by High-Performance Liquid Chromatography/Electrospray Ionization/Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hye-Sung Cho

    2011-03-01

    Full Text Available Oxidation products of ceftiofur were formed in hydrogen peroxide solution. The structures of the ceftiofur oxidationproducts were characterized by high-performance liquid chromatography/electrospray ionization/tandem mass spectrometry(HPLC/ESI/MS/MS. The products were identified as compounds oxidized at the sulfur of a cephem ring. For further analysis,experiments were performed using O18-labeled hydrogen peroxide. In addition, density-functional calculations were carried out forsix possible oxidation products to support the experimental results.

  16. Determination of conjugated bile acids in human bile and duodenal fluid by reverse-phase high-performance liquid chromatography.

    Science.gov (United States)

    Bloch, C A; Watkins, J B

    1978-05-01

    A simple mehtod using reverse-phase liquid chromatography is presented for resolution and quantitation of the major conjugated bile acids of man, including the glycine and taurine conjugates of the dihydroxy bile acids, chenodeoxycholic and deoxycholic acid. Using modern, high-performance chromatographic equipment, analysis time is less than 30 minutes. The quantitative range of the method, with detection by refractive index, is 0.05 to 0.1 mumol of bile acid and the limit of detection for an injection sample is 0.01 mumol. This provides a sensitivity sufficient for analysis of dilute duodenal and gallbladder bile with minimal sample preparation.

  17. [Determination of 2,6-di-tertbutyl-4-methylphenol in an aviation jet fuel by high performance liquid chromatography].

    Science.gov (United States)

    Xiong, Zhong-qiang; Zhang, Xiang-wen; Zhou, Zhen-huan; Mi, Zhen-tao

    2002-07-01

    The content of antioxidant of 2,6-di-tertbutyl-4-methylphenol(BHT) in a new aviation jet fuel (HDF-1) was determined by high performance liquid chromatography. The influences of the volume ratio of methanol and acetate buffer and the flow rate for BHT separation from HDF-1 were studied and the best analysis conditions were obtained. The optimum volume ratio is 85:15 and the optimum flow rate is 1 mL/min. The relation of BHT mass fraction and its peak area has been analyzed and simulated. It was found that they had a good linear relationship.

  18. Simultaneous high performance liquid chromatographic analysis of vitamins B1, B2 and B6 in royal jelly

    OpenAIRE

    2004-01-01

    Royal jelly is used as a food supplement, popularly known as rich in B vitamins. The present work has two objectives: firstly, to apply simultaneous quantitative determination by High Performance Liquid Chromatography of thiamin (vitamin B1), riboflavin (vitamin B2) and pyridoxine (vitamin B6) and secondly to compare the obtained data with the Dietary Reference Intake (DRI) values. The values obtained showed no thiamin, a range from 20 to 171 ng g-1 of riboflavin and from 408 to 2 188 ng g-1 ...

  19. High-performance liquid chromatographic determination of free and total polyamines in human serum as fluorescamine derivatives.

    Science.gov (United States)

    Kai, M; Ogata, T; Haraguchi, K; Ohkura, Y

    1979-06-11

    A highly sensitive and simple fluorimetric method for the determination of free and total polyamines, spermidine, spermine, putrescine and cadaverine, in human serum by high-performance liquid chromatography is described. The polyamines, obtained after clean-up of deproteinized serum by Cellex P column chromatography, are converted to their fluorescamine derivatives in the presence of nickel ion which inhibits the reaction of interfering amines with fluorescamine, and the derivatives are separated simultaneously by reversed-phase chromatography (LiChrosorb RP-18) with a linear gradient elution. The lower limits of detection are 10 and 15 pmole for spermine and the others in 0.5 ml of serum, respectively.

  20. Determination of oxytetracycline in milk samples by polymer inclusion membrane separation coupled to high performance liquid chromatography.

    Science.gov (United States)

    Pérez-Silva, Irma; Rodríguez, José A; Ramírez-Silva, Ma Teresa; Páez-Hernández, Ma Elena

    2012-03-09

    The determination of oxytetracycline in milk samples using a polymer inclusion membrane concept with high performance liquid chromatography (HPLC) was studied. The membranes developed are composed by cellulose acetate as polymer base, Cyanex 923 as carrier and o-nitrophenyl octyl ether as plasticizer. In the optimal conditions, the method exhibits good linearity in the range 0.03-0.20 mg L(-1) with a limit of detection and quantification of 8.2 and 27.3 μg L(-1) respectively. The method was successfully applied to the analysis of milk samples with high selectivity.

  1. Separation of polyprenyl phosphate oligomerhomologues by reversed-phase ion-pair high-performance liquid chromatography.

    Science.gov (United States)

    Kozlov, Vyacheslav V; Danilov, Leonid L

    2012-01-01

    A simple and rapid method of reversed-phase ion-pair high-performance liquid chromatography (HPLC) with UV-detection on a common C(18) column in an isocratic mode with the addition of tetrabutylammonium phosphate for the separation of polyprenyl phosphate oligomerhomologues has been developed. The method was successfully applied to assay the composition of polyprenyl phosphates obtained from polyprenols isolated from mulberry (Morus alba) leaves and fir (Abies sibirica) needles (the active components of veterinary drugs Gamapren and Phosprenyl correspondingly).

  2. Reversed-phase ion-pair high-performance liquid chromatography assay of polyprenyl diphosphate oligomer homologues.

    Science.gov (United States)

    Kozlov, Vyacheslav V; Danilov, Leonid L

    2016-02-01

    A reversed-phase ion-pair high-performance liquid chromatography procedure was developed for the separation of polyprenyl diphosphate oligomer homologues obtained chemically from plant polyprenols. Tetrabutylammonium phosphate was used as the ion-pair reagent, and the dependence of the separation quality on pH of ion-pair reagent was investigated for the first time. The procedure is applicable for the control of commercial available polyprenyl monophosphates (the active components of veterinary drugs Phosprenyl and Gamapren) for the possible presence of polyprenyl diphosphate byproducts. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Investigation into the temporal stability of aqueous standard solutions of psilocin and psilocybin using high performance liquid chromatography.

    Science.gov (United States)

    Anastos, N; Barnett, N W; Pfeffer, F M; Lewis, S W

    2006-01-01

    This paper reports an investigation into the temporal stability of aqueous solutions of psilocin and psilocybin reference drug standards over a period of fourteen days. This study was performed using high performance liquid chromatography utilising a (95:5% v/v) methanol: 10 mM ammonium formate, pH 3.5 mobile phase and absorption detection at 269 nm. It was found that the exclusion of light significantly prolonged the useful life of standards, with aqueous solutions of both psilocin and psilocybin being stable over a period of seven days.

  4. Determination of methyldibromoglutaronitrile in cosmetic products by high-performance liquid chromatography with electrochemical detection. Method validation

    DEFF Research Database (Denmark)

    Rastogi, Suresh Chandra; Zachariae, Claus; Johansen, Jeanne D

    2004-01-01

    An increased frequency of contact allergy to methyldibromoglutaronitrile (MDBGN), a commonly used preservative in cosmetics and other consumer products, has been reported in recent years. A high-performance liquid chromatography (HPLC) method for the determination of MDBGN in cosmetic products has...... been validated in the present study. The identification is performed by reductive electrochemical detection of the bromine present in the molecule. The method is suitable for compliance testing of cosmetic products as well as for the research to support clinical and epidemiological studies....

  5. Improvement of the analysis of dansylated derivatives of polyamines and their conjugates by high-performance liquid chromatography.

    Science.gov (United States)

    Fontaniella, B; Mateos, J L; Vicente, C; Legaz, M E

    2001-06-15

    The paper described a method for improving the hydrolysis of conjugated polyamines in PH fraction, isolated from the lichen Evernia prunastri, as well as the optimization of dansylation procedure of these polyamines on the basis of the pH value to which derivatization is achieved. Dansylated polyamines have been later separated by high-performance liquid chromatography (HPLC) using a gradient elution. Hydrolysis of conjugates requires acid treatment at room temperature rather than at 110 degrees C, as usually described. Dansylation is improved at high pH values, whereas removal of phenolics (mainly evernic acid), from the conjugates requires low pH values.

  6. Optimization of two methods for the analysis of hydrogen peroxide: high performance liquid chromatography with fluorescence detection and high performance liquid chromatography with electrochemical detection in direct current mode.

    Science.gov (United States)

    Tarvin, Megan; McCord, Bruce; Mount, Kelly; Sherlach, Katy; Miller, Mark L

    2010-11-26

    Two complementary methods were optimized for the separation and detection of trace levels of hydrogen peroxide. The first method utilized reversed-phase high-performance liquid chromatography with fluorescence detection (HPLC-FD). With this approach, hydrogen peroxide was detected based upon its participation in the hemin-catalyzed oxidation of p-hydroxyphenylacetic acid to yield the fluorescent dimer. The second method utilized high performance liquid chromatography with electrochemical detection (HPLC-ED). With this approach, hydrogen peroxide was detected based upon its oxidation at a gold working electrode at an applied potential of 400 mV vs. hydrogen reference electrode (Pd/H(2)). Both methods were linear across the range of 15-300 μM, and the electrochemical method was linear across a wider range of 7.4-15,000 μM. The limit of detection for hydrogen peroxide was 6 μM by HPLC/FD, and 0.6 μM by HPLC/ED. A series of organic peroxides and inorganic ions were evaluated for their potential to interfere with the detection of hydrogen peroxide. Studies investigating the recovery of hydrogen peroxide with three different extraction protocols were also performed. Post-blast debris from the detonation of a mixture of concentrated hydrogen peroxide with nitromethane was analyzed on both systems. Hydrogen peroxide residues were successfully detected on this post-blast debris.

  7. Methods of analysis by the U.S. Geological Survey Organic Geochemistry Research Group; determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    Science.gov (United States)

    Zimmerman, L.R.; Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: acetochlor ethanesulfonic acid (ESA), acetochlor oxanilic acid (OXA), alachlor ESA, alachlor OXA, metolachlor ESA, and metolachlor OXA. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The mean HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.50, and 2.0 mg/L (micrograms per liter) ranged from 84 to 112 percent, with relative standard deviations of 18 percent or less. The mean HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.20, and 2.0 mg/L ranged from 81 to 125 percent, with relative standard deviations of 20 percent or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 mg/L, whereas the LOQ using the HPLC/MS method was 0.05 mg/L. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water.

  8. Effects of boiling duration in processing of White Paeony Root on its overall quality evaluated by ultra-high performance liquid chromatography quadrupole/time-of-flight mass spectrometry based metabolomics analysis and high performance liquid chromatography quantification.

    Science.gov (United States)

    Ming, Kong; Xu, Jun; Liu, Huan-Huan; Xu, Jin-Di; Li, Xiu-Yang; Lu, Min; Wang, Chun-Ru; Chen, Hu-Biao; Li, Song-Lin

    2017-01-01

    Boiling processing is commonly used in post-harvest handling of White Paeony Root (WPR), in order to whiten the herbal materials and preserve the bright color, since such WPR is empirically considered to possess a higher quality. The present study was designed to investigate whether and how the boiling processing affects overall quality of WPR. First, an ultra-high performance liquid chromatography quadrupole/time-of-flight mass spectrometry-based metabolomics approach coupled with multivariate statistical analysis was developed to compare the holistic quality of boiled and un-boiled WPR samples. Second, ten major components in WPR samples boiled for different durations were quantitatively determined using high performance liquid chromatography to further explore the effects of boiling time on the holistic quality of WPR, meanwhile the appearance of the processed herbal materials was observed. The results suggested that the boiling processing conspicuously affected the holistic quality of WPR by simultaneously and inconsistently altering the chemical compositions and that short-time boiling processing between 2 and 10 min could both make the WPR bright-colored and improve the contents of major bioactive components, which were not achieved either without boiling or with prolonged boiling. In conclusion, short-term boiling (2-10 min) is recommended for post-harvest handling of WPR.

  9. Stability and Degradation of Caffeoylquinic Acids under Different Storage Conditions Studied by High-Performance Liquid Chromatography with Photo Diode Array Detection and High-Performance Liquid Chromatography with Electrospray Ionization Collision-Induced Dissociation Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Meng Xue

    2016-07-01

    Full Text Available Caffeoylquinic acids (CQAs are main constituents in many herbal medicines with various biological and pharmacological effects. However, CQAs will degrade or isomerize when affected by temperature, pH, light, etc. In this study, high-performance liquid chromatography with photodiode array detection (HPLC-PDA and high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS was utilized to study the stability and degradation of CQAs (three mono-acyl CQAs and four di-acyl CQAs under various ordinary storage conditions (involving different temperatures, solvents, and light irradiation. The results indicated that the stability of CQAs was mainly affected by temperature and light irradiation, while solvents did not affect it in any obvious way under the conditions studied. Mono-acyl CQAs were generally much more stable than di-acyl CQAs under the same conditions. Meanwhile, the chemical structures of 30 degradation products were also characterized by HPLC-MSn, inferring that isomerization, methylation, and hydrolysis were three major degradation pathways. The result provides a meaningful clue for the storage conditions of CQAs standard substances and samples.

  10. Peptide profiling of Internet-obtained Cerebrolysin using high performance liquid chromatography - electrospray ionization ion trap and ultra high performance liquid chromatography - ion mobility - quadrupole time of flight mass spectrometry.

    Science.gov (United States)

    Gevaert, Bert; D'Hondt, Matthias; Bracke, Nathalie; Yao, Han; Wynendaele, Evelien; Vissers, Johannes Petrus Cornelis; De Cecco, Martin; Claereboudt, Jan; De Spiegeleer, Bart

    2015-09-01

    Cerebrolysin, a parenteral peptide preparation produced by controlled digestion of porcine brain proteins, is an approved nootropic medicine in some countries. However, it is also easily and globally available on the Internet. Nevertheless, until now, its exact chemical composition was unknown. Using high performance liquid chromatography (HPLC) coupled to ion trap and ultra high performance liquid chromatography (UHPLC) coupled to quadrupole-ion mobility-time-of-flight mass spectrometry (Q-IM-TOF MS), combined with UniProt pig protein database search and PEAKS de novo sequencing, we identified 638 unique peptides in an Internet-obtained Cerebrolysin sample. The main components in this sample originate from tubulin alpha- and beta-chain, actin, and myelin basic protein. No fragments of known neurotrophic factors like glial cell-derived neurotrophic factor (GDNF), neurotrophin nerve growth factor (NGF), brain-derived neurotrophic factor (BDNF), and ciliary neurotrophic factor (CNTF) were found, suggesting that the activities reported in the literature are likely the result of new, hitherto unknown cryptic peptides with nootropic properties.

  11. One-pot preparation of a novel monolith for high performance liquid chromatography applications.

    Science.gov (United States)

    Jiao, Xiaoyan; Shen, Shigang; Shi, Tiesheng

    2015-12-15

    Various novel porous organic-based monoliths with the mode of hydrophobicity were synthesized by in situ free-radical crosslinking copolymerization and optimized for the separations of small molecules and high-performance reversed-phase chromatography (RP-chromatography). These monoliths contained co-polymers based on glycidyl methacrylate (GMA)/ethylene glycol dimethacrylate (EDMA)/tripropylene glycol diacrylate (TPGDA) or EDMA/TPGDA. A mixture of cetanol, methanol and poly (ethylene glycol) (PEG) was used as the porogen, with the ratio of these solvents being varied along with the polymerization temperature to generate a library of monoliths. The conditions were optimized and the resulting poly (GMA-co-TPGDA-co-EDMA) monolith was investigated by infrared spectrometer (IR), field emission scanning electron microscope (FESEM), and mercury intrusion porosimetry (MIP), respectively. The column performance was assessed by the separation of a series of neutral solutes of benzene derivatives. The result demonstrated that the prepared monolith exhibited an RP-chromatographic behavior and relatively homogeneous structure, good permeability and separation performance. Moreover, the relative standard deviations (RSDs) of the retention factor values for benzene derivatives were less than 1.5% (n=7, column-to-column). The approach used in this study was extended to the separation of anilines.

  12. Fast and comprehensive analysis of secondary metabolites in cocoa products using ultra high-performance liquid chromatography directly after pressurized liquid extraction.

    Science.gov (United States)

    Damm, Irina; Enger, Eileen; Chrubasik-Hausmann, Sigrun; Schieber, Andreas; Zimmermann, Benno F

    2016-08-01

    Fast methods for the extraction and analysis of various secondary metabolites from cocoa products were developed and optimized regarding speed and separation efficiency. Extraction by pressurized liquid extraction is automated and the extracts are analyzed by rapid reversed-phase ultra high-performance liquid chromatography and normal-phase high-performance liquid chromatography methods. After extraction, no further sample treatment is required before chromatographic analysis. The analytes comprise monomeric and oligomeric flavanols, flavonols, methylxanthins, N-phenylpropenoyl amino acids, and phenolic acids. Polyphenols and N-phenylpropenoyl amino acids are separated in a single run of 33 min, procyanidins are analyzed by normal-phase high-performance liquid chromatography within 16 min, and methylxanthins require only 6 min total run time. A fourth method is suitable for phenolic acids, but only protocatechuic acid was found in relevant quantities. The optimized methods were validated and applied to 27 dark chocolates, one milk chocolate, two cocoa powders and two food supplements based on cocoa extract.

  13. Heat exchanges in fast, high-performance liquid chromatography. A complete thermodynamic study

    Energy Technology Data Exchange (ETDEWEB)

    Gritti, Fabrice [University of Tennessee, Knoxville (UTK); Guiochon, Georges A [ORNL

    2008-01-01

    The successive physical transformations of the mobile phase that take place in very high pressure liquid chromatography were studied based on the formalism of classical thermodynamics. The eluent is initially under atmospheric pressure (P{sup 0}) and at ambient temperature (T{sub ext}). In a first step, it is compressed to a high pressure (P{sub max} of the order of 1 kbar) in the pump heads of the chromatograph. In a second step, the pressurized eluent is transferred to the inlet of the chromatographic column, along which, in a third step, it is decompressed to atmospheric pressure. Both the compression and the decompression of the fluid were considered to take place under conditions that can be either adiabatic or nonadiabatic and either reversible or irreversible. Applications of the first and second principles of thermodynamics allow the determination of the heat and energy exchanged between the eluent and the external surroundings during each transformation. Experimental data were acquired using acetonitrile as the mobile phase. The true state equation, {rho}(P, T), of liquid acetonitrile was used in the theoretical calculations. A series of four different flow rates (0.55, 0.85, 1.15, and 1.45 mL/min, corresponding to inlet pressures of 357.2, 559.5, 765.1, and 972.9 bar, respectively), were applied to a 2.1 x 100 mm column packed with 1.7-{micro}m bridged ethane-silicon hybrid particles. Thermocouples were used to measure the eluent temperature before and after its passage through the column. These data provide estimates of the variation of the internal energy of the eluent. The heat lost through the external wall of the column during the eluent decompression was estimated by measuring the surface temperature of the column tube under steady state. Both the compression and the decompression of acetonitrile were found to be nonadiabatic and irreversible transformations. The results showed that, during the eluent decompression, the heat released by the friction

  14. Salting-out homogenous extraction followed by ionic liquid/ionic liquid liquid-liquid micro-extraction for determination of sulfonamides in blood by high performance liquid chromatography.

    Science.gov (United States)

    Liu, Zhongling; Yu, Wei; Zhang, Hanqi; Gu, Fanbin; Jin, Xiangqun

    2016-12-01

    Salting-out homogenous extraction followed by ionic liquid/ionic liquid dispersive liquid-liquid micro-extraction system was developed and applied to the extraction of sulfonamides in blood. High-performance liquid chromatography was applied to the determination of the analytes. The blood sample was centrifuged to obtain the serum. After the proteins in the serum were removed in the presence of acetonitrile, ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate, dipotassium hydrogen phosphate, ionic liquid 1-Hexyl-3-methylimidazolium hexafluorophosphate were added into the resulting solution. After the resulting mixture was ultrasonically shaken and centrifuged, the precipitate was separated. The acetonitrile was added in the precipitate and the analytes were extracted into the acetonitrile phase. The parameters affecting the extraction efficiency, such as volume of ionic liquid, amount of dipotassium hydrogen phosphate, volume of dispersant, extraction time and temperature were investigated. The limits of detection of sulfamethizole (STZ), sulfachlorpyridazine (SCP), sulfamethoxazole (SMX) and Sulfisoxazole (SSZ) were 4.78, 3.99, 5.21 and 3.77μgL(-1), respectively. When the present method was applied to the analysis of real blood samples, the recoveries of analytes ranged from 90.0% to 113.0% and relative standard deviations were lower than 7.2%.

  15. Acetonitrile shortage: use of isopropanol as an alternative elution system for ultra/high performance liquid chromatography†

    Science.gov (United States)

    Desai, Ankur M.; Andreae, Mark; Mullen, Douglas G.; Holl, Mark M. Banaszak; Baker, James R.

    2010-01-01

    Acetonitrile is a choice of solvent for almost all chromatographic separations. In recent years, researchers around the globe have faced an acetonitrile shortage that affected routine analytical operations. Researchers have tried to counter this shortage by applying many innovative solutions, including using ultra performance liquid chromatography (UPLC) columns that are shorter and smaller in diameter than traditional high performance liquid chromatography (HPLC) columns, thus significantly decreasing the volume of eluent required. Although utilizing UPLC in place of HPLC can alleviate the solvent demand to some extent, acetonitrile is generally thought of as the solvent of choice due to its versatility. In the following communication, we describe an alternative eluent system that uses isopropanol in place of acetonitrile as an organic modifier for routine chromatographic separations. We report here the development of an isopropanol based UPLC protocol for G5 PAMAM dendrimer based conjugates that was transferred to semi-preparative applications. PMID:21572563

  16. Phytochemical analysis of Hibiscus caesius using high performance liquid chromatography coupled with mass spectrometry.

    Science.gov (United States)

    Ain, Quratul; Naveed, Muhammad Na; Mumtaz, Abdul Samad; Farman, Muhammad; Ahmed, Iftikhar; Khalid, Nauman

    2015-09-01

    Various species in genus Hibiscus are traditionally known for their therapeutic attributes. The present study focused on the phytochemical analysis of a rather unexplored species Hibiscus caesius (H. caesius), using high-pressure liquid chromatography coupled with mass spectrometry (HPLC-MS). The analysis revealed five major compounds in the aqueous extract, viz. vanillic acid, protocatechoic acid, quercetin, quercetin glucoside and apigenin, being reported for the first time in H. caesius. Literature suggests that these compounds have important pharmacological traits such as anti-cancer, anti-inflammatory, anti-bacterial and hepatoprotective etc. however, this requires further pharmacological investigations at in vitro and in vivo scale. The above study concluded the medicinal potential of H. caesius.

  17. [Determination of four phenolic endocrine disruptors in environmental water samples by high performance liquid chromatography-fluorescence detection using dispersive liquid-liquid microextraction coupled with derivatization].

    Science.gov (United States)

    Wang, Xiaoyan; Qi, Weimei; Zhao, Xian'en; Lü, Tao; Wang, Xiya; Zheng, Longfang; Yan, Yehao; You, Jinmao

    2014-06-01

    To achieve accurate, fast and sensitive detection of phenolic endocrine disruptors in small volume of environmental water samples, a method of dispersive liquid-liquid microextraction (DLLME) coupled with fluorescent derivatization was developed for the determination of bisphenol A, nonylphenol, octylphenol and 4-tert-octylphenol in environmental water samples by high performance liquid chromatography-fluorescence detection (HPLC-FLD). The DLLME and derivatization conditions were investigated, and the optimized DLLME conditions for small volume of environmental water samples (pH 4.0) at room temperature were as follows: 70 microL chloroform as extraction solvent, 400 microL acetonitrile as dispersing solvent, vortex mixing for 3 min, and then high-speed centrifugation for 2 min. Using 2-[2-(7H-dibenzo [a, g] carbazol-7-yl)-ethoxy] ethyl chloroformate (DBCEC-Cl) as precolumn derivatization reagent, the stable derivatives of the four phenolic endocrine disruptors were obtained in pH 10.5 Na2CO3-NaHCO3 buffer/acetonitrile at 50 degrees C for 3 min, and then separated within 10 min by HPLC-FLD. The limits of detection (LODs) were in the range of 0.9-1.6 ng/L, and the limits of quantification (LOQs) were in the range of 3.8-7.1 ng/L. This method had perfect linearity, precision and recovery results, and showed obvious advantages and practicality comparing to the previously reported methods. It is a convenient and validated method for the routine analysis of phenolic endocrine disruptors in waste water of paper mill, lake water, domestic wastewater, tap water, etc.

  18. Determination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography

    Science.gov (United States)

    Parsaei, Parvin; Bahmaei, Manouchehr; Ghannadi, AliReza

    2014-01-01

    Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile phase consisted of 8% methanol and 92% aqueous phase (1% (V/V) acetic acid water solution); flow rate, 0.7 mL/min; detection wavelength, 260 nm and pH, 3.3. The extraction efficiency of thiamine, nicotinamide and pyridoxine was influenced by factors such as: additional salt effect, the kind and volume of disperser and extraction solvents. In this research, the limit of detection (LOD) and quantification (LOQ) were 0.9 and 3 ng/mL for thiamine, 1.5 and 5 ng/mL for nicotinamide, 0.9 and 3 ng/mL for pyridoxine. The relative standard deviations (RSDs) were less than 2.87% (n=3). An appropriate linear behavior over the observed concentration range was obtained with the value of R²>0.996 for the target vitamins. This method was successfully applied to the sour cherry juice samples. Sour cherry var. Gise (Prunus cerasus var. Gise), which was used in this research, was a local variety of the sour cherry with large stone, double flowers, double fruits, dark red skin and dark red juice. This variety was identified in high altitude areas of Isfahan province after five years of study, since 2005, by Agricultural and Natural Resources Research Center of Isfahan. PMID:25587335

  19. Analysis of biogenic amines in wines by salting-out assisted liquid-liquid extraction and high-performance liquid chromatography with fluorimetric detection.

    Science.gov (United States)

    Ramos, Rui Miguel; Valente, Inês Maria; Rodrigues, José António

    2014-06-01

    Biogenic amines are nitrogenous organic compounds of low molecular weight that are either formed or metabolized in cells of living organisms and can be found in several food products, being produced mainly by amino acid decarboxylation. When ingested in high concentrations they can induce several health problems in humans. In alcoholic beverages, and especially in wine, they are formed during the vinification process as a result of the action of microorganisms. In this work it is proposed a new methodology for the determination of biogenic amines in wines, which includes a sample preparation approach based on salting-out assisted liquid-liquid extraction, the use of dansyl chloride for the derivatization and chromatographic separation by high-performance liquid chromatography with fluorimetric detection. The salting-out effect is used to promote phase separation between water and a water-miscible organic solvent, while improving the extraction of organic or inorganic species. Several extraction parameters were optimized, such as the dansyl chloride concentration, pH and the effects caused by the order in which the extraction and derivatization were performed. Extraction of amines, and consequent detection, depends on the presence of dansyl chloride in solution prior to extraction. The results showed the possibility to simultaneously perform the extraction and the derivatization, making sample preparation easier and less time-consuming. The methodology was successfully applied to the determination of biogenic amines in five wines (white, red and rosé). This method has the potential to be a good alternative to existing methods since it is cheaper, easier and simplifies the sample preparation step.

  20. Proteomic analysis of Taenia ovis metacestodes by high performance liquid chromatography-coupled tandem mass spectrometry.

    Science.gov (United States)

    Zheng, Yadong

    2017-03-15

    Taenia ovis metacestodes reside in the muscle of sheep and goats, and may cause great economic loss due to condemnation of carcasses if not effectively controlled. Although advances have been made in the control of T. ovis infection, our knowledge of T. ovis biology is limited. Herein the protein profiling of T. ovis metacestodes was determined by liquid chromatography-linked tandem mass spectrometry. A total of 966 proteins were identified and 25.1% (188/748) were annotated to be associated with metabolic pathways. Consistently, GO analysis returned a metabolic process (16.27%) as one of two main biological process terms. Moreover, it was found that 24 proteins, including very low-density lipoprotein receptor, enolase, paramyosin and endophilin B1, were abundant in T. ovis metacestodes. These proteins may be associated with motility, metabolism, signaling, stress, drug resistance and immune responses. Furthermore, comparative analysis of 5 cestodes revealed the presence of Taenia-specific enolases. These data provide clues for better understanding of T. ovis biology, which is informative for effective control of infection.

  1. Comprehensive sample analysis using high performance liquid chromatography with multi-detection

    Energy Technology Data Exchange (ETDEWEB)

    Pravadali, Sercan [Australian Centre for Research on Separation Sciences (ACROSS), School of Science and Health, University of Western Sydney (Parramatta), NSW 1797 (Australia); Bassanese, Danielle N.; Conlan, Xavier A.; Francis, Paul S.; Smith, Zoe M.; Terry, Jessica M. [Centre for Chemistry and Biotechnology, School of Life and Environmental Sciences, Deakin University, Victoria 3216 (Australia); Shalliker, R. Andrew, E-mail: R.Shalliker@uws.edu.au [Australian Centre for Research on Separation Sciences (ACROSS), School of Science and Health, University of Western Sydney (Parramatta), NSW 1797 (Australia)

    2013-11-25

    Graphical abstract: -- Highlights: •Detection selectivity was assessed with 6 detection modes. •Natural samples show great diversity in detection selectivity. •Complex samples require evaluation using a multifaceted approach to detection. •23/30 known compounds (detected by MS) detected by chemiluminescence, DPPH and UV. -- Abstract: Herein we assess the separation space offered by a liquid chromatography system with an optimised uni-dimensional separation for the determination of the key chemical entities in the highly complex matrix of a tobacco leaf extract. Multiple modes of detection, including UV–visible absorbance, chemiluminescence (acidic potassium permanganate, manganese(IV), and tris(2,2′-bipyridine)ruthenium(III)), mass spectrometry and DPPH radical scavenging were used in an attempt to systematically reduce the data complexity of the sample whilst obtaining a greater degree of molecule-specific information. A large amount of chemical data was obtained, but several limitations in the ability to assign detector responses to particular compounds, even with the aid of complementary detection systems, were observed. Thirty-three compounds were detected via MS on the tobacco extract and 12 out of 32 compounds gave a peak height ratio (PHR) greater than 0.33 on one or more detectors. This paper serves as a case study of these limitations, illustrating why multidimensional chromatography is an important consideration when developing a comprehensive chemical detection system.

  2. Parallel segmented outlet flow high performance liquid chromatography with multiplexed detection

    Energy Technology Data Exchange (ETDEWEB)

    Camenzuli, Michelle [Australian Centre for Research on Separation Science (ACROSS), School of Science and Health, University of Western Sydney (Parramatta), Sydney, NSW (Australia); Terry, Jessica M. [Centre for Chemistry and Biotechnology, School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3216 (Australia); Shalliker, R. Andrew, E-mail: r.shalliker@uws.edu.au [Australian Centre for Research on Separation Science (ACROSS), School of Science and Health, University of Western Sydney (Parramatta), Sydney, NSW (Australia); Conlan, Xavier A.; Barnett, Neil W. [Centre for Chemistry and Biotechnology, School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3216 (Australia); Francis, Paul S., E-mail: paul.francis@deakin.edu.au [Centre for Chemistry and Biotechnology, School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3216 (Australia)

    2013-11-25

    Graphical abstract: -- Highlights: •Multiplexed detection for liquid chromatography. •‘Parallel segmented outlet flow’ distributes inner and outer portions of the analyte zone. •Three detectors were used simultaneously for the determination of opiate alkaloids. -- Abstract: We describe a new approach to multiplex detection for HPLC, exploiting parallel segmented outlet flow – a new column technology that provides pressure-regulated control of eluate flow through multiple outlet channels, which minimises the additional dead volume associated with conventional post-column flow splitting. Using three detectors: one UV-absorbance and two chemiluminescence systems (tris(2,2′-bipyridine)ruthenium(III) and permanganate), we examine the relative responses for six opium poppy (Papaver somniferum) alkaloids under conventional and multiplexed conditions, where approximately 30% of the eluate was distributed to each detector and the remaining solution directed to a collection vessel. The parallel segmented outlet flow mode of operation offers advantages in terms of solvent consumption, waste generation, total analysis time and solute band volume when applying multiple detectors to HPLC, but the manner in which each detection system is influenced by changes in solute concentration and solution flow rates must be carefully considered.

  3. Determination of microsomal CYP2A6 activity by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Lavhekar S

    2007-01-01

    Full Text Available Coumarin has been reported to be a reliable probe for the determination of human microsomal CYP2A6 activity. Coumarin is converted to 7-hydroxycoumarin by CYP2A6. A high pressure liquid chromatographic assay for the estimation of CYP2A6 activity in microsomes was evaluated. A RP C-18 Novapak Waters (15 cm x 3.9 mm, 5 µm column was used for the assay. The mobile phase composition was methanol : 1% glacial acetic acid (35:65 v/v (pH~3.1, with a flow rate of 0.6 ml/min, injection volume of 100 µl and detection at 320 nm. The retention times for coumarin and 7-hydroxycoumarin were 8.7 min and 5.3 min, respectively. The limit of detection (LOD was 0.05 µM, and the limit of quantitation (LOQ was 0.1 µM, for 7-hydroxycoumarin. The percent coefficient of variation associated with 7-hydroxycoumarin determination after duplicate estimation was found to be in the range 0.03 to 3.6% for buffer matrix and 0.1 to 6.5% for microsomal matrix. The mean rate of 7-hydroxycoumarin formation in guinea pig liver microsomes was 0.084 nmol/min/nmol P450. Coumarin 7-hydroxylase activity was absent in rat liver microsomes. No interference was observed from incubation mixture components.

  4. Hazards of Secondary Bromadiolone Intoxications Evaluated using High-performance Liquid Chromatography with Electrochemical Detection

    Directory of Open Access Journals (Sweden)

    René Kizek

    2007-07-01

    Full Text Available This study reported on the possibility of intoxications of non-target wild animalsassociated with use of bromadiolone as the active component of rodenticides withanticoagulation effects. A laboratory test was done with earthworms were exposed tobromadiolone-containing granules under the conditions specified in the modified OECD207 guideline. No mortality of earthworms was observed during the fourteen days longexposure. When the earthworms from the above test became a part of the diet of commonvoles in the following experiment, no mortality of consumers was observed too. However,electrochemical analysis revealed higher levels of bromadiolone in tissues fromearthworms as well as common voles compared to control animals. There were determinedcomparable levels of bromadiolone in the liver tissue of common voles after primary(2.34±0.10 μg/g and secondary (2.20±0.53 μg/g intoxication. Therefore, the risk ofsecondary intoxication of small mammalian species feeding on bromadiolone-containing earthworms is the same as of primary intoxication through baited granules. Bromadiolone bio-accumulation in the food chain was monitored using the newly developed analytical procedure based on the use of a liquid chromatography coupled with electrochemical detector (HPLC-ED. The HPLC-ED method allowed to determine the levels of bromadiolone in biological samples and is therefore suitable for examining the environmental hazards of this substance.

  5. Development and validation of a specific stability indicating high performance liquid chromatographic method for rizatriptan benzoate.

    Science.gov (United States)

    Mallikarjuna Rao, B; Sangaraju, Sivaiah; Srinivasu, M K; Madhavan, P; Lalitha Devi, M; Rajendra Kumar, P; Chandrasekhar, K B; Arpitha, Ch; Satya Balaji, T

    2006-06-16

    A gradient, reversed-phase liquid chromatographic (RP-LC) method was developed for the quantitative determination of rizatriptan benzoate, used to treat relieves migraine headache symptoms. The developed method can be also employed for the related substance determination in bulk samples. Forced degradation studies were performed on bulk sample of rizatriptan benzoate using acid (0.5 N hydrochloric acid), base (0.1 N sodium hydroxide), oxidation (3.0% hydrogen peroxide), water hydrolysis, heat (60 degrees C) and photolytic degradation. Mild degradation of the drug substance was observed in base hydrolysis and considerable degradation observed during oxidative stress. The chromatographic method was fine tuned using the samples generated from forced degradation studies. Good resolution between the peaks corresponds to degradation products and the analyte was achieved on Agilent Zorbax SB-CN (250 mm x 4.6 mm, 5 microm) column. The mobile phase consists of a mixture of aqueous potassium di hydrogen ortho phosphate (pH 3.4), acetonitrile and methanol. The stress sample solutions were assayed against the qualified reference standard of rizatriptan benzoate and the mass balance in each case was close to 99.7% indicating that the developed method is stability indicating. Validation of the developed method was carried out as per ICH requirements.

  6. [Determination of gossypol in edible vegetable oil with high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhang, Wenhua; Huang, Chaoqun; Xie, Wen; Shen, Li

    2014-06-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of gossypol in edible vegetable oil. The sample was extracted with ethyl alcohol by vortex-excited oscillation. The extract was cleaned up by 0.22 microm filter membrane and centrifuged for 5 min at 4 000 r/min after standing in a fridge at 4 degrees C for 30 min. The compound was separated on a C18 column (100 mm x 2.1 mm, 3.5 microm) with acetonitrile and 1% (v/v) formic acid aqueous solution as mobile phase. The detection of gossypol was carried out by LC-MS/MS with positive electrospray ionization under multiple reaction monitoring (MRM) mode using external standard method. The limits of quantification (S/N > 10) of gossypol in edible vegetable oil was 1 mg/kg. The recoveries were from 87.4% to 100% at the spiked levels of 1, 2, 200 mg/kg of gossypol in edible vegetable oil with the relative standard deviations (RSDs) between 3.9% and 12.2%. The method, with high sensitivity, good precision and high recovery, was suitable for the confirmation and quantification of gossypol residue in edible vegetable oil.

  7. High-performance lubricant additives based on modified graphene oxide by ionic liquids.

    Science.gov (United States)

    Fan, Xiaoqiang; Wang, Liping

    2015-08-15

    Graphene oxide (GO) is a layered material bearing a variety of oxygen-containing functional groups on its basal planes and edges, which allow it as a substrate to conduct a variety of chemical transformations. Here modified graphene oxide (MGO) was prepared using alkyl imidazolium ionic liquids (ILs) (1-butyl-3-methylimidazolium tetrafluoroborate (LB104), 1-butyl-3-methyl imidazolium hexafluorophosphate (LP104) and 1-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl) amide (LF106)) via epoxide ring-opening reaction, cation-π stacking or van der Waals interactions, with LB104 modified graphene (MG) exfoliated from graphite rod by a moderate electrochemical method as a comparison. The stability and tribological properties of MGO and MG as multialkylated cyclopentanes (MACs) additives were investigated in detail. The results show that GO is converted into graphene through the chemical modification using ILs, and MGO with good dispersion and stability in MACs significantly improves the tribological performance (friction and wear were reduced about 27% and 74% with pure MACs as a comparison, respectively). The excellent tribological properties are attributed to the formation of an ILs-containing graphene-rich tribofilm on the sliding surfaces, which as the third body can prevent the sliding surfaces from straight asperity contact and improve friction reducing and anti-wear behaviors.

  8. High performance hybrid supercapacitors by using para-Benzoquinone ionic liquid redox electrolyte

    Science.gov (United States)

    Navalpotro, Paula; Palma, Jesús; Anderson, Marc; Marcilla, Rebeca

    2016-02-01

    A solution of 0.4M para-Benzoquinone (p-BQ) in the ionic liquid N-butyl-N-methylpyrrolidinium bis(trifluoromethanesulfonyl) imide (PYR14TFSI) was used as a redox electrolyte in hybrid supercapacitors. Two carbons with very different textural properties, Pica carbon and Vulcan carbon, were used as electrode material. Electrochemical performance of these energy storage systems was investigated by cyclic voltammetry (CV) and galvanostatic charge-discharge (CD). Unlike SCs with pure IL electrolyte, new battery-like features appeared in the CV curves and CD profiles. This electrochemical performance, associated with the faradaic contribution of the redox electrolyte, results in a significant improvement of the electrochemical performance of the hybrid system. For Vulcan carbon with low specific surface area (SBET = 240 m2 g-1), specific capacitance (Cs) and specific real energy (Ereal) values as high as 70 Fg-1 and 10.3 WhKg-1 were obtained at 5 mAcm-2 with hybrid SC operating at 3 V. This represents an increment of 300% in Cs and Ereal with respect to the SC based on pure PYR14TFSI. For high surface area carbon such as Pica (SBET = 2410 m2g-1), the addition of the redox quinone molecule resulted in a moderate enhancement reaching values of 156 Fg-1 and 30 WhKg-1 under the same experimental conditions (36% and 10% increment, respectively).

  9. High-performance liquid chromatography with fluorescence detection for the rapid analysis of pheophytins and pyropheophytins in virgin olive oil.

    Science.gov (United States)

    Li, Xueqi; Woodman, Michael; Wang, Selina C

    2015-08-01

    Pheophytins and pyropheophytin are degradation products of chlorophyll pigments, and their ratios can be used as a sensitive indicator of stress during the manufacturing and storage of olive oil. They increase over time depending on the storage condition and if the oil is exposed to heat treatments during the refining process. The traditional analysis method includes solvent- and time-consuming steps of solid-phase extraction followed by analysis by high-performance liquid chromatography with ultraviolet detection. We developed an improved dilute/fluorescence method where multi-step sample preparation was replaced by a simple isopropanol dilution before the high-performance liquid chromatography injection. A quaternary solvent gradient method was used to include a fourth strong solvent wash on a quaternary gradient pump, which avoided the need to premix any solvents and greatly reduced the oil residues on the column from previous analysis. This new method not only reduces analysis cost and time but shows reliability, repeatability, and improved sensitivity, especially important for low-level samples.

  10. Analysis of therapeutic proteins and peptides using multiangle light scattering coupled to ultra high performance liquid chromatography.

    Science.gov (United States)

    Espinosa-de la Garza, Carlos E; Miranda-Hernández, Mariana P; Acosta-Flores, Lilia; Pérez, Néstor O; Flores-Ortiz, Luis F; Medina-Rivero, Emilio

    2015-05-01

    Analysis of the physical properties of biotherapeutic proteins is crucial throughout all the stages of their lifecycle. Herein, we used size-exclusion ultra high performance liquid chromatography coupled to multiangle light scattering and refractive index detection systems to determine the molar mass, mass-average molar mass, molar-mass dispersity and hydrodynamic radius of two monoclonal antibodies (rituximab and trastuzumab), a fusion protein (etanercept), and a synthetic copolymer (glatiramer acetate) employed as models. A customized instrument configuration was set to diminish band-broadening effects and enhance sensitivity throughout detectors. The customized configuration showed a performance improvement with respect to the high-performance liquid chromatography standard configuration, as observed by a 3 h column conditioning and a higher resolution analysis in 20 min. Analysis of the two monoclonal antibodies showed averaged values of 148.0 kDa for mass-average molar mass and 5.4 nm for hydrodynamic radius, whereas for etanercept these values were 124.2 kDa and 6.9 nm, respectively. Molar-mass dispersity was 1.000 on average for these proteins. Regarding glatiramer acetate, a molar mass range from 3 to 45 kDa and a molar-mass dispersity of 1.304 were consistent with its intrinsic peptide diversity, and its mass-average molar mass was 10.4 kDa. Overall, this method demonstrated an accurate determination of molar mass, overcoming the difficulties of size-exclusion chromatography.

  11. High performance liquid chromatography coupled with resonance Rayleigh scattering for the detection of three fluoroquinolones and mechanism study

    Science.gov (United States)

    Zhou, Mingqiong; Peng, Jingdong; He, Rongxing; He, Yuting; Zhang, Jing; Li, Aiping

    2015-02-01

    A reliable and versatile high performance liquid chromatography coupled with resonance Rayleigh scattering method was established for the determination of three fluoroquinolones, including levofloxacin, norfloxacin and enrofloxacin in water sample and human urine sample. In pH 4.4-4.6 Britton-Robinson buffer medium, the fluoroquinolones separated by high performance liquid chromatography could react with erythrosine to form 1:1 ion-association complexes, which could make contributions to the great enhancement of RRS. The resonance Rayleigh scattering signal was recorded at λex = λem = 330 nm. The resonance Rayleigh scattering spectral characteristics of the drugs and the experimental conditions such as pH, detection wavelength, erythrosine concentration, flow rate, the length of reaction tube were studied. Quantum chemistry calculation, Fourier transform infrared spectroscopy and absorption spectroscopy were used to discuss the reaction mechanism. The recoveries of samples added standard ranged from 97.53% to 102.00%, and the relative standard deviation was below 4.64%. The limit of detection (S/N = 3) of 0.05-0.12 μg mL-1 was reached, and the linear regression coefficients were all above 0.999. The proposed method was proved as a simple, low cost and high sensitivity method.

  12. Identification of Explosives from Porous Materials: Applications Using Reverse Phase High Performance Liquid Chromatography and Gas Chromatography

    Science.gov (United States)

    Miller, C. J.; Elias, G.; Schmitt, N. C.; Rae, C.

    2010-06-01

    High performance liquid chromatography and gas chromatography techniques are well documented and widely used for the detection of trace explosives from organic solvents. These techniques were modified to identify and quantify explosives extracted from various materials taken from people who had recently handled explosives. Documented techniques were modified to specifically detect and quantify trace levels of the military explosives, RDX, TNT, and PETN from denim, colored flannel, vinyl, and canvas extracted in methanol and filtered using no additional sample cleanup of the sample extract prior to analysis. The filtered methanol extracts were injected directly into several different column types and analyzed by high performance liquid chromatography using ultraviolet detection and/or gas chromatography using electron capture detection. This paper describes general screening methods that were used to determine the presence of explosives (RDX, TNT, and PETN) in unknown samples of denim, colored flannel, vinyl and canvas in addition to techniques that have been optimized for quantification of each explosive from the substrate extracts.

  13. Strategy for reduced calibration sets to develop quantitative structure-retention relationships in high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Andries, Jan P.M. [University of Professional Education, Department of Life Sciences, P.O. Box 90116, 4800 RA Breda (Netherlands); Claessens, Henk A. [University of Professional Education, Department of Life Sciences, P.O. Box 90116, 4800 RA Breda (Netherlands); Eindhoven University of Technology, Department of Chemical Engineering and Chemistry, Laboratory of Polymer Chemistry, P.O. Box 513 (Helix, STW 1.35), 5600 MB Eindhoven (Netherlands); Heyden, Yvan Vander [Department of Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, B-1090 Brussels (Belgium); Buydens, Lutgarde M.C., E-mail: L.Buydens@science.ru.nl [Institute for Molecules and Materials, Radboud University Nijmegen, Toernooiveld 1, 6525 ED Nijmegen (Netherlands)

    2009-10-12

    In high-performance liquid chromatography, quantitative structure-retention relationships (QSRRs) are applied to model the relation between chromatographic retention and quantities derived from molecular structure of analytes. Classically a substantial number of test analytes is used to build QSRR models. This makes their application laborious and time consuming. In this work a strategy is presented to build QSRR models based on selected reduced calibration sets. The analytes in the reduced calibration sets are selected from larger sets of analytes by applying the algorithm of Kennard and Stone on the molecular descriptors used in the QSRR concerned. The strategy was applied on three QSRR models of different complexity, relating logk{sub w} or log k with either: (i) log P, the n-octanol-water partition coefficient, (ii) calculated quantum chemical indices (QCI), or (iii) descriptors from the linear solvation energy relationship (LSER). Models were developed and validated for 76 reversed-phase high-performance liquid chromatography systems. From the results we can conclude that it is possible to develop log P models suitable for the future prediction of retentions with as few as seven analytes. For the QCI and LSER models we derived the rule that three selected analytes per descriptor are sufficient. Both the dependent variable space, formed by the retention values, and the independent variable space, formed by the descriptors, are covered well by the reduced calibration sets. Finally guidelines to construct small calibration sets are formulated.

  14. [Determination of sugars, organic acids and alcohols in microbial consortium fermentation broth from cellulose using high performance liquid chromatography].

    Science.gov (United States)

    Jiang, Yan; Fan, Guifang; Du, Ran; Li, Peipei; Jiang, Li

    2015-08-01

    A high performance liquid chromatographic method was established for the determination of metabolites (sugars, organic acids and alcohols) in microbial consortium fermentation broth from cellulose. Sulfate was first added in the samples to precipitate calcium ions in microbial consortium culture medium and lower the pH of the solution to avoid the dissociation of organic acids, then the filtrates were effectively separated using high performance liquid chromatography. Cellobiose, glucose, ethanol, butanol, glycerol, acetic acid and butyric acid were quantitatively analyzed. The detection limits were in the range of 0.10-2.00 mg/L. The linear correlation coefficients were greater than 0.999 6 in the range of 0.020 to 1.000 g/L. The recoveries were in the range of 85.41%-115.60% with the relative standard deviations of 0.22% -4.62% (n = 6). This method is accurate for the quantitative analysis of the alcohols, organic acids and saccharides in microbial consortium fermentation broth from cellulose.

  15. High-performance liquid chromatographic assay of parabens in wash-off cosmetic products and foods using chemiluminescence detection

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Qunlin [Department of Chemistry, University of Science and Technology of China, Jinzai Road 96, Hefei, Anhui 230026 (China); Lian Mei [Department of Chemistry, University of Science and Technology of China, Jinzai Road 96, Hefei, Anhui 230026 (China); Liu Lijuan [Department of Chemistry, University of Science and Technology of China, Jinzai Road 96, Hefei, Anhui 230026 (China); Cui Hua [Department of Chemistry, University of Science and Technology of China, Jinzai Road 96, Hefei, Anhui 230026 (China)]. E-mail: hcui@ustc.edu.cn

    2005-04-29

    A new method for the simultaneous determination of parabens including methylparaben, ethylparaben, propylparaben, and butylparaben by high-performance liquid chromatography (HPLC) coupled with chemiluminescence detection was developed. The procedure was based on the chemiluminescent enhancement by parabens of the cerium(IV)-rhodamine 6G system in the strong sulfuric acid medium. The good separation of parabens was carried out with an isocratic elution using a mixture of methanol and water (60:40, v/v) within 8.5 min. Under the optimized conditions, a linear working range extends three orders of magnitude with the relative standard deviations of intra- and inter-day precision below 4.5%, and the detection limits were 1.9 x 10{sup -9}, 2.7 x 10{sup -9}, 3.9 x 10{sup -9}, and 5.3 x 10{sup -9} g ml{sup -1} for methylparaben, ethylparaben, propylparaben, and butylparaben, respectively. The chemiluminescence reaction was well compatible with the mobile phase of high-performance liquid chromatography. The proposed method has been successfully applied to the assay of parabens in wash-off cosmetic products and foods with the minimal sample preparation.

  16. Isolation and purification of diastereoisomeric flavonolignans from silymarin by binary-column recycling preparative high-performance liquid chromatography.

    Science.gov (United States)

    Zhao, Weiquan; Yang, Guang; Zhong, Fanyi; Yang, Nan; Zhao, Xin; Qi, Yunpeng; Fan, Guorong

    2014-09-01

    Silymarin extracted from Silybum marianum (L.) Gaertn consists of a large number of flavonolignans, of which diastereoisomeric flavonolignans including silybin A and silybin B, and isosilybin A and isosilybin B are the main bioactive components, whose preparation from the crude extracts is still a difficult task. In this work, binary-column recycling preparative high-performance liquid chromatography systems without sample loop trapping, where two columns were switched alternately via one or two six-port switching valves, were established and successfully applied to the isolation and purification of the four diastereoisomeric flavonolignans from silymarin. The proposed system showed significant advantages over conventional preparative high-performance liquid chromatography with a single column in increasing efficiency and reducing the cost. To obtain the same amounts of products, the proposed system spends only one tenth of the time that the conventional system spends, and needs only one eleventh of the solvent that the conventional system consumes. Using the proposed system, the four diastereoisomers were successfully isolated from silymarin with purities over 98%.

  17. Rapid determination of trace semicarbazide in flour products by high-performance liquid chromatography based on a nucleophilic substitution reaction.

    Science.gov (United States)

    Wei, Tianfu; Li, Gongke; Zhang, Zhuomin

    2017-05-01

    Semicarbazide, a toxic food contaminant, widely exists in food products and it originates from the thermal degradation of a food additive of azodicarbonamide or a metabolite of nitrofurazone abused in meat specimens. Many previous methods for semicarbazide determination usually required expensive instruments, difficult-to-prepare monoclonal antibodies, and a long operation time. In this study, a high-performance liquid chromatography method was developed for the rapid determination of trace semicarbazide coupling with a nucleophilic substitution reaction firstly using 4-nitrobenzoyl chloride as derivatization reagent. The derivatization reaction was mild at room temperature for 1 min in neutral solution. Then, semicarbazide derivative was separated and quantified by high-performance liquid chromatography with ultraviolet detection under optimal separation conditions at λmax = 261 nm. The proposed method offered the detection limit of 1.8 μg/L and was successfully applied for the rapid determination of trace semicarbazide in flour products. Semicarbazide in positive real samples could be actually found and quantified in the range of 0.47-7.53 mg/kg. The recoveries were 76.6-119% with relative standard deviations of 0.5-9.1% (n = 3). This developed method was rapid, reliable, and convenient for the determination of trace semicarbazide in food. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Analysis of anti-platelet aggregation components of Rhizoma Zingiberis using chicken thrombocyte extract and high performance liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    NIE Hong; MENG Lan-zhen; ZHANG Hui; ZHANG Jian-yu; YIN Zhen; HUANG Xue-song

    2008-01-01

    Background The conventional procedure for screening bioactive components from traditional Chinese medicine is time-consuming,expensive and low efficient.Therefore,some alternative strategies are needed urgently.A novel method for screening anti-platelet aggregation components from oleoresins was developed using chicken thrombocyte extract and high performance liquid chromatography.Methods The anti-platelet aggregation components of oleoresins were combined with receptors,channels and enzymes of chicken thrombocytes under physiological environment.Unbound substances were washed away and bound compounds were eluted using specific phosphate buffered solution(PBS).Compounds released from target sites were collected and analyzed by high performance liquid chromatography and LC-MS.The activity of three compounds which were screened from this model was confirmed using platelet aggregation pharmacology in vivo.Results There were four typical compounds that bound to the thrombocytes:6-gingerol,8-gingerol,6-shogaol and 10-gingerol,and all had shown anti-platelet aggregation activities.Eight-gingerol displayed the best anti-platelet aggregation effect.Conclusions Chicken thromobcyte extract can be used to isolate chemicals that are ligands of the receptor or other bio-targets on the platelet.This may therefore be a simple and efficient method to screen for anti-platelet aggregation compounds from traditional Chinese medicine.

  19. Ultra-high performance liquid chromatographic determination of antioxidants in teas using inkjet-printed graphene-polyaniline electrode.

    Science.gov (United States)

    Bardpho, Chayanee; Rattanarat, Poomrat; Siangproh, Weena; Chailapakul, Orawon

    2016-02-01

    A development of ultra-high performance liquid chromatographic coupled with a novel inkjet-printed conductive ink-modified electrode for a fast and simultaneous determination of polyphenolic antioxidants was achieved. Two printing techniques were selected for fabrication and modification including (i) an in-house screen-printing method and (ii) an inkjet-printing method, respectively. A conductive ink containing graphene and polyaniline nanocomposite (G-PANI) was precisely casted onto the surface of screen-printed carbon electrode (SPCE) using a dimatix inkjet material printer. Compared to a bare SPCE, the G-PANI-modified screen-printed carbon electrode (G-PANI/SPCE) exhibited higher electrochemical sensitivity with increase (2-4 times) of peak current of each antioxidant. Moreover, four antioxidants were successfully separated and determined within 3 min using a reverse phase ultra-high performance liquid chromatography (UHPLC) with a mobile phase containing phosphate buffer and acetonitrile (90:10 v/v). Under an optimal detection potential at +1.2V vs. Ag/AgCl, linear calibrations and limits of detection (S/N=3) for antioxidants were found to be 0.01-10 µg mL(-1) and 1.38-1.94 ng mL(-1), respectively. Finally, this proposed method has been successfully used for the determination of antioxidants in tea samples, the results obtained from our presented method were within a highly good agreement those obtained from a standard UHPLC-UV method.

  20. Quantitative analysis of lactose and lactulose in urine by high performance liquid chromatography for determination of intestinal lactase activity

    Directory of Open Access Journals (Sweden)

    Nani Dharmasetiawani

    2003-03-01

    Full Text Available Determination of intestinal lactase activity is directly done by measuring its activity in intestinal epithelium. This is an invasive method and ethically can not be done in healthy infants. Indirectly, determination of lactase activity, stated as excretion and ingestion ratio of lactose and lactulose, needs 30 hours hospitalized infants. The aim of this study was to look for a method for determination of lactase activity which is not invasive and not necessary hospitalized. Using this method  lactose and lactulose were given as a single oral load after 2 hours fasting. Urine were collected for 5 hours starting from consuming sugar solution and then lactose and lactulose concentration in the urine were measured by High Performance Liquid Chromatography. The results showed single oral load of lactose and lactulose can be used for determination of lactase activity in infant and the infants were observed only for 7 hours. (Med J Indones 2003; 12: 8-12 Keywords: Lactase activity, Lactulose, Lactose, High Performance Liquid Chromatography