WorldWideScience

Sample records for high-intensity ultra-short laser

  1. Reflectivity of plasmas created by high-intensity, ultra-short laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Gold, David Michael [Univ. of California, Davis, CA (United States)

    1994-06-01

    Experiments were performed to characterize the creation and evolution of high-temperature (T e~100eV), high-density (ne>1022cm-3) plasmas created with intense (~1012-1016W/cm2), ultra-short (130fs) laser pulses. The principle diagnostic was plasma reflectivity at optical wavelengths (614nm). An array of target materials (Al, Au, Si, SiO2) with widely differing electronic properties tested plasma behavior over a large set of initial states. Time-integrated plasma reflectivity was measured as a function of laser intensity. Space- and time-resolved reflectivity, transmission and scatter were measured with a spatial resolution of ~3μm and a temporal resolution of 130fs. An amplified, mode-locked dye laser system was designed to produce ~3.5mJ, ~130fs laser pulses to create and nonintrusively probe the plasmas. Laser prepulse was carefully controlled to suppress preionization and give unambiguous, high-density plasma results. In metals (Al and Au), it is shown analytically that linear and nonlinear inverse Bremsstrahlung absorption, resonance absorption, and vacuum heating explain time-integrated reflectivity at intensities near 1016W/cm2. In the insulator, SiO2, a non-equilibrium plasma reflectivity model using tunneling ionization, Helmholtz equations, and Drude conductivity agrees with time-integrated reflectivity measurements. Moreover, a comparison of ionization and Saha equilibration rates shows that plasma formed by intense, ultra-short pulses can exist with a transient, non-equilibrium distribution of ionization states. All targets are shown to approach a common reflectivity at intensities ~1016W/cm2, indicating a material-independent state insensitive to atomic or solid-state details.

  2. Theory and simulation of ultra-short pulse laser interactions

    Energy Technology Data Exchange (ETDEWEB)

    More, R.; Walling, R.; Price, D.; Guethlein, G.; Stewart, R.; Libby, S.; Graziani, F.; Levatin, J. [Lawrence Livermore National Lab., Livermore, CA (United States)

    1998-03-01

    This paper describes recent Livermore work aimed at building computational tools to describe ultra-short pulse laser plasmas. We discuss calculations of laser absorption, atomic data for high-charge ions, and a new idea for linear-response treatment of non-equilibrium phenomena near LTE. (author)

  3. Ultra-short pulsed laser engineered metal-glass nanocomposites

    CERN Document Server

    Stalmashonak, Andrei; Abdolvand, Amin

    2013-01-01

    Glasses containing metallic nanoparticles exhibit very promising linear and nonlinear optical properties, mainly due to the surface plasmon resonances (SPRs) of the nanoparticles. The spectral position in the visible and near-infrared range and polarization dependence of the SPR are characteristically determined by the nanoparticles’ shapes. The focus of Ultra-Short Pulsed Laser Engineered Metal-Glass Nanocomposites is the interaction of intense ultra-short laser pulses with glass containing silver nanoparticles embedded in soda-lime glass, and nanostructural modifications in metal-glass nanocomposites induced by such laser pulses. In order to provide a comprehensive physical picture of the processes leading to laser-induced persistent shape transformation of the nanoparticles, series of experimental results investigating the dependences of laser assisted shape modifications of nanoparticles with laser pulse intensity, excitation wavelength, temperature are considered. In addition, the resulting local opti...

  4. 3d particle simulations on ultra short laser interaction

    Energy Technology Data Exchange (ETDEWEB)

    Nishihara, Katsunobu; Okamoto, Takashi; Yasui, Hidekazu [Osaka Univ., Suita (Japan). Inst. of Laser Engineering

    1998-03-01

    Two topics related to ultra short laser interaction with matter, linear and nonlinear high frequency conductivity of a solid density hydrogen plasma and anisotropic self-focusing of an intense laser in an overdense plasma, have been investigated with the use of 3-d particle codes. Frequency dependence of linear conductivity in a dense plasma is obtained, which shows anomalous conductivity near plasma frequency. Since nonlinear conductivity decreases with v{sub o}{sup -3}, where v{sub o} is a quivering velocity, an optimum amplitude exists leading to a maximum electron heating. Anisotropic self-focusing of a linear polarized intense laser is observed in an overdense plasma. (author)

  5. Extending ultra-short pulse laser texturing over large area

    Energy Technology Data Exchange (ETDEWEB)

    Mincuzzi, G., E-mail: girolamo.mincuzzi@alphanov.com; Gemini, L.; Faucon, M.; Kling, R.

    2016-11-15

    Highlights: • We carried out metal surface texturing (Ripples, micro grooves, Spikes) using a high power, high repetition rate, industrial, Ultra-short pulses laser. • Extremely Fast processing is shown (Laser Scan speed as high as 90 m/s) with a polygon scanner head. • Stainless steel surface blackening with Ultra-short pulses laser has been obtained with unprecedented scanspeed. • Full SEM surface characterization was carried out for all the different structures obtained. • Reflectance measurements were carried out to characterize surface reflectance. - Abstract: Surface texturing by Ultra-Short Pulses Laser (UPL) for industrial applications passes through the use of both fast beam scanning systems and high repetition rate, high average power P, UPL. Nevertheless unwanted thermal effects are expected when P exceeds some tens of W. An interesting strategy for a reliable heat management would consists in texturing with a low fluence values (slightly higher than the ablation threshold) and utilising a Polygon Scanner Heads delivering laser pulses with unrepeated speed. Here we show for the first time that with relatively low fluence it is possible over stainless steel, to obtain surface texturing by utilising a 2 MHz femtosecond laser jointly with a polygonal scanner head in a relatively low fluence regime (0.11 J cm{sup −2}). Different surface textures (Ripples, micro grooves and spikes) can be obtained varying the scan speed from 90 m s{sup −1} to 25 m s{sup −1}. In particular, spikes formation process has been shown and optimised at 25 m s{sup −1} and a full morphology characterization by SEM has been carried out. Reflectance measurements with integrating sphere are presented to compare reference surface with high scan rate textures. In the best case we show a black surface with reflectance value < 5%.

  6. Metal Processing with Ultra-Short Laser Pulses

    Energy Technology Data Exchange (ETDEWEB)

    Banks, P S; Feit, M D; Komashko, A M; Perry, M D; Rubenchik, A M; Stuart, B C

    2000-05-01

    Femtosecond laser ablation has been shown to produce well-defined cuts and holes in metals with minimal heat effect to the remaining material. Ultrashort laser pulse processing shows promise as an important technique for materials processing. We will discuss the physical effects associated with processing based experimental and modeling results. Intense ultra-short laser pulse (USLP) generates high pressures and temperatures in a subsurface layer during the pulse, which can strongly modify the absorption. We carried out simulations of USLP absorption versus material and pulse parameters. The ablation rate as function of the laser parameters has been estimated. Since every laser pulse removes only a small amount of material, a practical laser processing system must have high repetition rate. We will demonstrate that planar ablation is unstable and the initially smooth crater bottom develops a corrugated pattern after many tens of shots. The corrugation growth rate, angle of incidence and the polarization of laser electric field dependence will be discussed. In the nonlinear stage, the formation of coherent structures with scales much larger than the laser wavelength was observed. Also, there appears to be a threshold fluence above which a narrow, nearly perfectly circular channel forms after a few hundred shots. Subsequent shots deepen this channel without significantly increasing its diameter. The role of light absorption in the hole walls will be discussed.

  7. Generation of ultra-short relativistic-electron-bunch by a laser wakefield

    NARCIS (Netherlands)

    Khachatryan, A.G.; Boller, Klaus J.; van Goor, F.A.

    2003-01-01

    The possibility of the generation of an ultra-short (about one micron long) relativistic (up to a few GeVs) electron-bunch in a moderately nonlinear laser wakefield excited in an underdense plasma by an intense laser pulse is investigated. The ultra-short bunch is formed by trapping, effective

  8. SOLID BODY ABLATION UNDER EXPOSURE TO ULTRA SHORT LASER PULSES: STUDY BY MOLECULAR DYNAMICS METHODS

    OpenAIRE

    D. S. Ivanov; V. P. Veiko; Y. B. Yakovlev; M. E. Carcia; Rethfeld, B.

    2014-01-01

    The process of laser ablation under the influence of ultra short laser pulses on metals is investigated by methods of molecular dynamics. The validity and applicability of the hybrid atomistic-continuous model for the estimation of optimum modes of ultra short laser pulses processing are explored. Combination of atomistic model of laser-induced non-equilibrium process of a phase transition at the atomic level with continuous two-temperature model for describing the dynamics of photo-excitatio...

  9. Laser system using ultra-short laser pulses

    Science.gov (United States)

    Dantus, Marcos [Okemos, MI; Lozovoy, Vadim V [Okemos, MI; Comstock, Matthew [Milford, MI

    2009-10-27

    A laser system using ultrashort laser pulses is provided. In another aspect of the present invention, the system includes a laser, pulse shaper and detection device. A further aspect of the present invention employs a femtosecond laser and binary pulse shaping (BPS). Still another aspect of the present invention uses a laser beam pulse, a pulse shaper and a SHG crystal.

  10. Ultra short pulse laser generated surface textures for anti-ice applications in aviation

    NARCIS (Netherlands)

    Römer, G.W.; Del Cerro, D.A.; Sipkema, R.C.J.; Groenendijk, M.N.W.; Huis in 't Veld, A.J.

    2009-01-01

    By laser ablation with ultra short laser pulses in the pico- and femto-second range, well controlled dual scaled micro- and nano-scaled surface textures can be obtained. The micro-scale of the texture is mainly determined by the dimensions of the laser spot, whereas the superimposed nano-structure

  11. Erosion resistant anti-ice surfaces generated by ultra short laser pulses

    NARCIS (Netherlands)

    Del Cerro, D.A.; Römer, G.R.B.E.; Huis in't Veld, A.J.

    2010-01-01

    Wetting properties of a wide range of materials can be modified by accurate laser micromachining with ultra short laser pulses. Controlling the surface topography in a micro and sub-micrometer scale allows the generation of water-repellent surfaces, which remain dry and prevent ice accumulation

  12. Annealing of SnO2 thin films by ultra-short laser pulses

    NARCIS (Netherlands)

    Scorticati, D.; Illiberi, A.; Bor, Teunis Cornelis; Eijt, S.W.H.; Schut, H.; Römer, Gerardus Richardus, Bernardus, Engelina; de Lange, D.F.; Huis in 't Veld, Bert

    2014-01-01

    Post-deposition annealing by ultra-short laser pulses can modify the optical properties of SnO2 thin films by means of thermal processing. Industrial grade SnO2 films exhibited improved optical properties after picosecond laser irradiation, at the expense of a slightly increased sheet resistance

  13. Gap bridging in joining of glass using ultra short laser pulses.

    Science.gov (United States)

    Cvecek, Kristian; Odato, Rainer; Dehmel, Sarah; Miyamoto, Isamu; Schmidt, Michael

    2015-03-09

    Glass welding by ultra-short laser pulses provides hermetic welding seams with high mechanical stability. The required distance between the samples must be extremely small (cracks will form inside the seam reducing its stability. However, to achieve such small gaps the roughness of the samples must be small enough necessitating additional polishing. Additionally, Van-der-Waals forces grow substantial at such distances thereby effectively preventing sample movement and an easy and precise sample alignment. Here we present a method utilizing ultra-short laser pulses which exploits a volume expansion of irradiated glass enabling the joining of glass plates across gaps of up to 1µm.

  14. Optical and electrical properties of SnO2 thin films after ultra-short pulsed laser annealing

    NARCIS (Netherlands)

    Scorticati, D.; Illiberi, A.; Römer, G.R.B.E.; Bor, T.; Ogieglo, W.; Klein Gunnewiek, M.; Lenferink, A.; Otto, C.; Skolski, J.Z.P.; Grob, F.; Lange, D.F. de; Huis in 't Veld, A.J.

    2013-01-01

    Ultra-short pulsed laser sources, with pulse durations in the ps and fs regime, are commonly exploited for cold ablation. However, operating ultra-short pulsed laser sources at fluence levels well below the ablation threshold allows for fast and selective thermal processing. The latter is especially

  15. Ultra-Short-Pulse Laser Effects Research and Analysis Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Enables research into advanced laser countermeasure techniques.DESCRIPTION: This laser facility has a capability to produce very high peak power levels of...

  16. Ultra-short pulse reconstruction software in high power laser system

    Energy Technology Data Exchange (ETDEWEB)

    Galletti, M. [Physics Department of the University and INFN, Pisa (Italy); Galimberti, M. [Central Laser Facility, Rutherford Appleton Laboratory, Didcot (United Kingdom); Giulietti, D. [Physics Department of the University and INFN, Pisa (Italy)

    2015-07-15

    An ultra-short pulse reconstruction software, validated through a set of experimental measurements on the front-end of the Vulcan laser at the RAL Central Laser Facility is presented. The measurements were acquired in Target Area Petawatt of the Vulcan laser, both using a conventional autocorrelation technique and the GRENOUILLE technique in order to compare the results. The FWHM of the laser pulses considered came out to be comparable for the two techniques. In this experimental campaign for the first time a technique different from the autocorrelation one has been used for a PW class laser as Vulcan.

  17. Ultra-short pulse reconstruction software in high power laser system

    Science.gov (United States)

    Galletti, M.; Galimberti, M.; Giulietti, D.

    2015-07-01

    An ultra-short pulse reconstruction software, validated through a set of experimental measurements on the front-end of the Vulcan laser at the RAL Central Laser Facility is presented. The measurements were acquired in Target Area Petawatt of the Vulcan laser, both using a conventional autocorrelation technique and the GRENOUILLE technique in order to compare the results. The FWHM of the laser pulses considered came out to be comparable for the two techniques. In this experimental campaign for the first time a technique different from the autocorrelation one has been used for a PW class laser as Vulcan.

  18. Novel oral applications of ultra-short laser pulses

    Science.gov (United States)

    Wieger, V.; Wernisch, J.; Wintner, E.

    2007-02-01

    In the past decades, many efforts have been made to replace mechanical tools in oral applications by various laser systems. The reasons therefore are manifold: i) Friction causes high temperatures damaging adjacent tissue. ii) Smear layers and rough surfaces are produced. iii) Size and shape of traditional tools are often unsuitable for geometrically complicated incisions and for minimum invasive treatment. iv) Mechanical damage of the remaining tissue occurs. v) Online diagnosis for feedback is not available. Different laser systems in the µs and sub-&mrgs-pulse regime, among them Erbium lasers, have been tested in the hope to overcome the mentioned drawbacks and, to some extent, they represent the current state of the art with respect to commercial and hence practical application. In the present work the applicability of scanned ultrashort pulse lasers (USPLs) for biological hard tissue as well as dental restoration material removal was tested. It is shown that cavities with features superior to mechanically treated or Erbium laser ablated cavities can be generated if appropriate scan algorithms and optimum laser parameters are matched. Smooth cavity rims, no microcracks, melting or carbonisation and precise geometry are the advantages of scanned USLP ablation. For bone treatment better healing conditions are expected as the natural structure remains unaffected by the preparation procedure. The novelty of this work is represented by a comprehensive compilation of various experimental results intended to assess the performance of USPLs. In this context, various pulse durations in the picosecond and femtosecond regime were applied to dental and bone tissue as well as dental restoration materials which is considered to be indispensable for a complete assessment. Parameters like ablation rates describing the efficiency of the ablation process, and ablation thresholds were determined - some of them for the first time - and compared to the corresponding Erbium

  19. SOLID BODY ABLATION UNDER EXPOSURE TO ULTRA SHORT LASER PULSES: STUDY BY MOLECULAR DYNAMICS METHODS

    Directory of Open Access Journals (Sweden)

    D. S. Ivanov

    2014-09-01

    Full Text Available The process of laser ablation under the influence of ultra short laser pulses on metals is investigated by methods of molecular dynamics. The validity and applicability of the hybrid atomistic-continuous model for the estimation of optimum modes of ultra short laser pulses processing are explored. Combination of atomistic model of laser-induced non-equilibrium process of a phase transition at the atomic level with continuous two-temperature model for describing the dynamics of photo-excitation of free media is proposed. Applicability of laser ablation model on the example of aluminum films and gold under exposure to pulses with different energy density and duration is shown. It is indicated that, depending on the ratio of the laser pulse duration and the characteristic time of electron-phonon material interaction, photothermal and photomechanical modes of destruction are implemented that determine the quality and performance of the laser processing. It is established that at the duration of laser pulse less than the time of electron-phonon interaction high-performance photomechanical type of destruction is implemented by internal stresses arising in the area of exposure. This is confirmed by a linear dependence of the ablation rate from the absorbed energy. At the duration of laser pulse greater than the time of electron-phonon interaction inefficient photothermal mode of destruction is implemented. The results may be useful for specialists engaged in the development of laser technologies

  20. Heat accumulation in ultra-short pulsed scanning laser ablation of metals.

    Science.gov (United States)

    Bauer, Franziska; Michalowski, Andreas; Kiedrowski, Thomas; Nolte, Stefan

    2015-01-26

    High average laser powers can have a serious adverse impact on the ablation quality in ultra-short pulsed laser material processing of metals. With respect to the scanning speed, a sharp transition between a smooth, reflective and an uneven, dark ablated surface is observed. Investigating the influence of the sample temperature, it is experimentally shown that this effect stems from heat accumulation. In a numerical heat flow simulation, the critical scanning speed indicating the change in ablation quality is determined in good agreement with the experimental data.

  1. Ultra-short wavelength operation in Thulium-doped silica fiber laser with bidirectional pumping

    Science.gov (United States)

    Xiao, Xusheng; Guo, Haitao; Yan, Zhijun; Wang, Hushan; Xu, Yantao; Lu, Min; Wang, Yishan; Peng, Bo

    2017-02-01

    An ultra-short wavelength operation of Tm-doped all fiber laser based on fiber Bragg gratings (FBGs) was developed. A bi-directional pump configuration for the ultra-short wavelength operation was designed and investigated for the first time. the laser yielded 3.15W of continuous-wave output at 1706.75nm with a narrow-linewidth of 50pm and a maximum slope efficiency of 42.1%. The dependencies of the slope efficiencies and pump threshold of the laser versus the length of active fiber and reflectivity of the output mirror (FBG) were investigated in detail. An experimental comparative study between two Thulium-doped fiber lasers (TDFLs) with two different pumping configuration(forward unidirectional pumping and bidirectional pumping) was presented. It is indisputable that the development of 1.7μm silicate fiber lasers with Watt-level output power open up a number of heart-stirring and tempting application windows.

  2. Microprocessing of thin collagen films by ultra-short laser ablation

    Science.gov (United States)

    Daskalova, A.; Manousaki, A.; Gray, D.; Fotakis, C.

    2010-10-01

    This preliminary work explores a technique for processing collagen thin films by femtosecond Ti:Sapphire laser ablation in order to provide a structured matrix support for cell growth and other tissue engineering applications. The laserinduced structuring of collagen easily yields an expanded micro foam material with interconnected pores and properties that mimics the native collagen-based extracellular matrix. The obtained structured matrix is formed by a cavitation and bubble growth mechanism. The surface properties of collagen thin films before and after Ti-sapphire irradiation with 800 nm were investigated by means of Field Emission Scanning Electron Microscope (FESEM) technique. FESEM analysis showed that with a single pulse of ultra-short laser radiation is capable of inducing morphological changes in the irradiated collagen films. The size of the observed features can be controlled by selection of laser fluence and pulse number. Collagen-based biomaterials were developed and explored for the purposes of tissue engineering. Biomaterials are expected to function as cell scaffolds to replace native collagen. The ultra-short laser ablation induced nanofoaming of biomaterials will improve currently available techniques. Artificial collagen nanofibers are increasingly significant in numerous tissue engineering applications and seem to be ideal scaffolds for cell growth and proliferation.

  3. An ultra short pulse reconstruction software applied to the GEMINI high power laser system

    Energy Technology Data Exchange (ETDEWEB)

    Galletti, Mario, E-mail: mario.gall22@gmail.com [INFN – LNF, Via Enrico Fermi 40, 00044 Frascati (Italy); Galimberti, Marco [Central Laser Facility, Rutherford Appleton Laboratory, Didcot (United Kingdom); Hooker, Chris [Central Laser Facility, Rutherford Appleton Laboratory, Didcot (United Kingdom); University of Oxford, Oxford (United Kingdom); Chekhlov, Oleg; Tang, Yunxin [Central Laser Facility, Rutherford Appleton Laboratory, Didcot (United Kingdom); Bisesto, Fabrizio Giuseppe [INFN – LNF, Via Enrico Fermi 40, 00044 Frascati (Italy); Curcio, Alessandro [INFN – LNF, Via Enrico Fermi 40, 00044 Frascati (Italy); Sapienza – University of Rome, P.le Aldo Moro, 2, 00185 Rome (Italy); Anania, Maria Pia [INFN – LNF, Via Enrico Fermi 40, 00044 Frascati (Italy); Giulietti, Danilo [Physics Department of the University and INFN, Pisa (Italy)

    2016-09-01

    The GRENOUILLE traces of Gemini pulses (15 J, 30 fs, PW, shot per 20 s) were acquired in the Gemini Target Area PetaWatt at the Central Laser Facility (CLF), Rutherford Appleton Laboratory (RAL). A comparison between the characterizations of the laser pulse parameters made using two different types of algorithms: Video Frog and GRenouille/FrOG (GROG), was made. The temporal and spectral parameters came out to be in great agreement for the two kinds of algorithms. In this experimental campaign it has been showed how GROG, the developed algorithm, works as well as VideoFrog algorithm with the PetaWatt pulse class. - Highlights: • Integration of the diagnostic tool on high power laser. • Validation of the GROG algorithm in comparison to a well-known commercial available software. • Complete characterization of the GEMINI ultra-short high power laser pulse.

  4. Mechanisms of nanoparticle formation by ultra-short laser ablation of metals in liquid environment.

    Science.gov (United States)

    Povarnitsyn, Mikhail E; Itina, Tatiana E; Levashov, Pavel R; Khishchenko, Konstantin V

    2013-03-07

    Laser ablation in liquids is now commonly used to produce colloidal nanoparticles (NPs) that have found numerous applications in different areas. In experiments, NPs of different materials can be rather easily obtained by using laser systems with various pulse durations, shapes, wavelengths, and fluences. In this paper, we focus our attention on metal (gold) NPs produced by ultra-short laser pulses. To better understand the mechanisms of the NPs formation, we perform modeling of femtosecond laser interactions with a gold target in the presence of liquid (water). Simulation of the ablation process over several nanoseconds shows that most of the primary NPs originate from the ablated metastable liquid layer, whereas only a minority is formed by condensation inside the cavitation bubble. These particles will further grow/evaporate, and coagulate during a much longer collision stage in the liquid colloid.

  5. Fundamental Physics Explored with High Intensity Laser

    Science.gov (United States)

    Tajima, T.; Homma, K.

    2012-10-01

    Over the last century the method of particle acceleration to high energies has become the prime approach to explore the fundamental nature of matter in laboratory. It appears that the latest search of the contemporary accelerator based on the colliders shows a sign of saturation (or at least a slow-down) in increasing its energy and other necessary parameters to extend this frontier. We suggest two pronged approach enabled by the recent progress in high intensity lasers. First we envision the laser-driven plasma accelerator may be able to extend the reach of the collider. For this approach to bear fruit, we need to develop the technology of high averaged power laser in addition to the high intensity. For this we mention that the latest research effort of ICAN is an encouraging sign. In addition to this, we now introduce the concept of the noncollider paradigm in exploring fundamental physics with high intensity (and large energy) lasers. One of the examples we mention is the laser wakefield acceleration (LWFA) far beyond TeV without large luminosity. If we relax or do not require the large luminosity necessary for colliders, but solely in ultrahigh energy frontier, we are still capable of exploring such a fundamental issue. Given such a high energetic particle source and high-intensity laser fields simultaneously, we expect to be able to access new aspects on the matter and the vacuum structure from fundamental physical point of views. LWFA naturally exploits the nonlinear optical effects in the plasma when it becomes of relativistic intensity. Normally nonlinear optical effects are discussed based upon polarization susceptibility of matter to external fields. We suggest application of this concept even to the vacuum structure as a new kind of order parameter to discuss vacuum-originating phenomena at semimacroscopic scales. This viewpoint unifies the following observables with the unprecedented experimental environment we envision; the dispersion relation of

  6. Ultra-short laser interactions with nanoparticles in different media: from electromagnetic to thermal and electrostatic effects

    Science.gov (United States)

    Itina, Tatiana E.

    2017-02-01

    Key issues of the controlled synthesis of nanoparticles and nanostructures, as well as laser-particle interactions are considered in the context of the latest applications appearing in many fields such as photonics, medicine, 3D printing, etc. The results of a multi-physics numerical study of laser interaction with nanoparticles will be presented in the presence of several environments. In particular, attention will be paid to the numerical study of laser interactions with heterogeneous materials (eg. colloidal liquids and/or nanoparticles in a dielectric medium) and the aggregation/sintering/fragmentation processes induced by ultra-short laser pulses.

  7. Ultra-short pulse laser micro patterning with highest throughput by utilization of a novel multi-beam processing head

    Science.gov (United States)

    Homburg, Oliver; Jarczynski, Manfred; Mitra, Thomas; Brüning, Stephan

    2017-02-01

    In the last decade much improvement has been achieved for ultra-short pulse lasers with high repetition rates. This laser technology has vastly matured so that it entered a manifold of industrial applications recently compared to mainly scientific use in the past. Compared to ns-pulse ablation ultra-short pulses in the ps- or even fs regime lead to still colder ablation and further reduced heat-affected zones. This is crucial for micro patterning when structure sizes are getting smaller and requirements are getting stronger at the same time. An additional advantage of ultra-fast processing is its applicability to a large variety of materials, e.g. metals and several high bandgap materials like glass and ceramics. One challenge for ultra-fast micro machining is throughput. The operational capacity of these processes can be maximized by increasing the scan rate or the number of beams - parallel processing. This contribution focuses on process parallelism of ultra-short pulsed lasers with high repetition rate and individually addressable acousto-optical beam modulation. The core of the multi-beam generation is a smooth diffractive beam splitter component with high uniform spots and negligible loss, and a prismatic array compressor to match beam size and pitch. The optical design and the practical realization of an 8 beam processing head in combination with a high average power single mode ultra-short pulsed laser source are presented as well as the currently on-going and promising laboratory research and micro machining results. Finally, an outlook of scaling the processing head to several tens of beams is given.

  8. High intensity laser interactions with atomic clusters

    Energy Technology Data Exchange (ETDEWEB)

    Ditmire, T

    2000-08-07

    The development of ultrashort pulse table top lasers with peak pulse powers in excess of 1 TW has permitted an access to studies of matter subject to unprecedented light intensities. Such interactions have accessed exotic regimes of multiphoton atomic and high energy-density plasma physics. Very recently, the nature of the interactions between these very high intensity laser pulses and atomic clusters of a few hundred to a few thousand atoms has come under study. Such studies have found some rather unexpected results, including the striking finding that these interactions appear to be more energetic than interactions with either single atoms or solid density plasmas. Recent experiments have shown that the explosion of such clusters upon intense irradiation can expel ions from the cluster with energies from a few keV to nearly 1 MeV. This phenomenon has recently been exploited to produce DD fusion neutrons in a gas of exploding deuterium clusters. Under this project, we have undertaken a general study of the intense femtosecond laser cluster interaction. Our goal is to understand the macroscopic and microscopic coupling between the laser and the clusters with the aim of optimizing high flux fusion neutron production from the exploding deuterium clusters or the x-ray yield in the hot plasmas that are produced in this interaction. In particular, we are studying the physics governing the cluster explosions. The interplay between a traditional Coulomb explosion description of the cluster disassembly and a plasma-like hydrodynamic explosion is not entirely understood, particularly for small to medium sized clusters (<1000 atoms) and clusters composed of low-Z atoms. We are focusing on experimental studies of the ion and electron energies resulting from such explosions through various experimental techniques. We are also examining how an intense laser pulse propagates through a dense medium containing these clusters.

  9. Precise ablation of dental hard tissues with ultra-short pulsed lasers. Preliminary exploratory investigation on adequate laser parameters.

    Science.gov (United States)

    Bello-Silva, Marina Stella; Wehner, Martin; Eduardo, Carlos de Paula; Lampert, Friedrich; Poprawe, Reinhart; Hermans, Martin; Esteves-Oliveira, Marcella

    2013-01-01

    This study aimed to evaluate the possibility of introducing ultra-short pulsed lasers (USPL) in restorative dentistry by maintaining the well-known benefits of lasers for caries removal, but also overcoming disadvantages, such as thermal damage of irradiated substrate. USPL ablation of dental hard tissues was investigated in two phases. Phase 1--different wavelengths (355, 532, 1,045, and 1,064 nm), pulse durations (picoseconds and femtoseconds) and irradiation parameters (scanning speed, output power, and pulse repetition rate) were assessed for enamel and dentin. Ablation rate was determined, and the temperature increase measured in real time. Phase 2--the most favorable laser parameters were evaluated to correlate temperature increase to ablation rate and ablation efficiency. The influence of cooling methods (air, air-water spray) on ablation process was further analyzed. All parameters tested provided precise and selective tissue ablation. For all lasers, faster scanning speeds resulted in better interaction and reduced temperature increase. The most adequate results were observed for the 1064-nm ps-laser and the 1045-nm fs-laser. Forced cooling caused moderate changes in temperature increase, but reduced ablation, being considered unnecessary during irradiation with USPL. For dentin, the correlation between temperature increase and ablation efficiency was satisfactory for both pulse durations, while for enamel, the best correlation was observed for fs-laser, independently of the power used. USPL may be suitable for cavity preparation in dentin and enamel, since effective ablation and low temperature increase were observed. If adequate laser parameters are selected, this technique seems to be promising for promoting the laser-assisted, minimally invasive approach.

  10. Propagation of the Ultra-Short Laser Pulses Through the Helical 1D Photonic Crystal Structure with Twist Defect

    Science.gov (United States)

    Antonov, Dmitrii V.; Iegorov, Roman

    2016-02-01

    The presence of the photonic band-gap is a featured property of the cholesteric liquid crystals (CLC). It can be practically realized for almost any reasonable wavelengths with very high degree of tunability. We have investigated theoretically the influence of the twist defect of the CLC helical structure onto the bandwidth-limited ultra-short laser pulse propagating inside the photonic band-gap. The changes of both pulse duration and peak power with defect angle were observed together with pulse acceleration and retardation for a case of normal incidence of the light.

  11. Transmission of 1064 nm laser radiation during ablation with an ultra-short pulse laser (USPL) system

    Science.gov (United States)

    Schelle, Florian; Meister, Jörg; Oehme, Bernd; Frentzen, Matthias

    2012-01-01

    During ablation of oral hard tissue with an USPL system a small amount of the incident laser power does not contribute to the ablation process and is being transmitted. Partial transmission of ultra-short laser pulses could potentially affect the dental pulp. The aim of this study was to assess the transmission during ablation and to deduce possible risks for the patient. The study was performed with an Nd:YVO4 laser, emitting pulses with a duration of 8 ps at a wavelength of 1064 nm. A repetition rate of 500 kHz and an average power of 9 W were chosen to achieve high ablation efficiency. A scanner system created square cavities with an edge length of 1 mm. Transmission during ablation of mammoth ivory and dentin slices with a thickness of 2 mm and 5 mm was measured with a power meter, placed directly beyond the samples. Effects on subjacent blood were observed by ablating specimens placed in contact to pork blood. In a separate measurement the temperature increase during ablation was monitored using an infrared camera. The influence of transmission was assessed by tuning down the laser to the corresponding power and then directly irradiating the blood. Transmission during ablation of 2 mm specimens was about 7.7% (ivory) and 9.6% (dentin) of the incident laser power. Ablation of specimens directly in contact to blood caused coagulation at longer irradiation times (t~18s). Direct irradiation of blood with the transmitted power provoked bubbling and smoke formation. Temperature measurements identified heat generation as the main reason for the observed coagulation.

  12. Morphology of ablation craters generated by ultra-short laser pulses in dentin surfaces: AFM and ESEM evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Daskalova, A., E-mail: a_daskalova@code.bg [Institute of Electronics, Bulgarian Academy of Sciences, 72, Tsarigradsko Chaussee Blvd., 1784 Sofia (Bulgaria); Bashir, S.; Husinsky, W. [IAP, Vienna University of Technology, Wiedner Hauptstrasse 8-10, 1040 Vienna (Austria)

    2010-11-15

    In this study, the surface morphology and structure of dentin after ablation by ultra-short pulses were evaluated using environmental scanning electron microscopy (ESEM) and atomic force microscopy (AFM). The dentin specimens examined were irradiated by a chirped-pulse-amplification (CPA) Ti:sapphire laser (800 nm) and the optimal conditions for producing various nanostructures were determined. Based on the ESEM results, it was possible to identify an energy density range as the ablation threshold for dentin. The laser-induced damage was characterized over the fluence range 1.3-2.1 J/cm{sup 2}. The results demonstrate that by selecting suitable parameters one can obtain efficient dentin surface preparation without evidence of thermal damage, i.e., with minimized heat affected zones and reduced collateral damage, the latter being normally characterized by formation of microcracks, grain growth and recrystallization in the heat affected zones.

  13. Femtosecond timing-jitter between photo-cathode laser and ultra-short electron bunches by means of hybrid compression

    CERN Document Server

    Pompili, Riccardo; Bellaveglia, M; Biagioni, A; Castorina, G; Chiadroni, E; Cianchi, A; Croia, M; Di Giovenale, D; Ferrario, M; Filippi, F; Gallo, A; Gatti, G; Giorgianni, F; Giribono, A; Li, W; Lupi, S; Mostacci, A; Petrarca, M; Piersanti, L; Di Pirro, G; Romeo, S; Scifo, J; Shpakov, V; Vaccarezza, C; Villa, F

    2017-01-01

    The generation of ultra-short electron bunches with ultra-low timing-jitter relative to the photo-cathode (PC) laser has been experimentally proved for the first time at the SPARC_LAB test-facility (INFN-LNF, Frascati) exploiting a two-stage hybrid compression scheme. The first stage employs RF-based compression (velocity-bunching), which shortens the bunch and imprints an energy chirp on it. The second stage is performed in a non-isochronous dogleg line, where the compression is completed resulting in a final bunch duration below 90 fs (rms). At the same time, the beam arrival timing-jitter with respect to the PC laser has been measured to be lower than 20 fs (rms). The reported results have been validated with numerical simulations.

  14. 978 nm 1.24 ps ultra-short plused large mode area photonic crystal fiber laser

    Science.gov (United States)

    Li, Pingxue; Liang, Boxing; Zhang, Mengmeng; Yao, Yifei; Chi, Junjie; Hu, Haowei; Zhang, Guangju; Ma, Chunmei; Su, Ning

    2015-10-01

    We report on a 980 nm passively mode-locking Yb-doped large mode area photonic crystal fiber oscillator with semiconductor saturable absorber mirror (SESAM) and nonlinear polarization evolution (NPE) technique, simultaneously. The oscillator generates a maximum average output power of 497 mW with a repetition rate of 87.37 MHz. Because of the invisible filter effect of NPE mode-locked fiber laser, we achieved an ultra-short pulse width of 1.24 ps. The output spectrum of the pulse is centered at 977.7 nm with a full width half maximum (FWHM) of 1.90 nm and has a characteristic steep spectral edges of dissipative soliton. In this paper, the pulse evolution process of 980 nm mode-locking fiber laser is simulated and the experimental results are good agreement with the simulation results.

  15. Au–C allotrope nano-composite films at extreme conditions generated by intense ultra-short laser

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Saif A., E-mail: khansaifahmad@gmail.com [Inter-University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110067 (India); Saravanan, K. [Department of Physics, Tamkang University, Tamsui 251, Taiwan (China); Tayyab, M.; Bagchi, S. [Laser Plasma Division, Raja Ramanna Centre for Advanced Technology, Indore 452013 (India); Avasthi, D.K. [Inter-University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110067 (India); Amity University, Noida 201313, Uttar Pradesh (India)

    2016-07-15

    Structural evolution of gold–carbon allotrope nano-composite films under relativistically intense, ultra-short laser pulse irradiation is studied in this work. Au–C nano-composite films, having 4 and 10 at.% of Au, were deposited by co-sputtering technique on silicon substrates. Au–C{sub 60} NC films with 2.5 at.% Au were deposited on 12 μm thick Al foil using co-evaporation technique. These samples were radiated with single pulse from 45 fs, 10 TW Ti:Sapphire Laser at RRCAT at an intensity of 3 × 10{sup 18} W cm{sup −2}. The morphological and compositional changes were investigated using scanning electron microscopy (SEM) and Rutherford back-scattering spectrometry (RBS) techniques. Laser pulse created three morphologically distinct zones around the point of impact on samples with silicon substrates. The gold content in 600 μm circular region around a point of impact is found to reduce by a factor of five. Annular rings of ∼70 nm in diameter were observed in case of Au–C NC film after irradiation. Laser pulse created a hole of about 400 μm in the sample with Al foil as substrate and wavy structures of 6 μm wavelength are found to be created around this hole. The study shows radial variation in nano-structure formation with varying local intensity of laser pulse.

  16. Time-dependent H-like and He-like Al lines produced by ultra-short pulse laser

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Takako; Kato, Masatoshi [National Inst. for Fusion Science, Nagoya (Japan); Shepherd, R.; Young, B.; More, R.; Osterheld, Al

    1998-03-01

    We have performed numerical modeling of time-resolved x-ray spectra from thin foil targets heated by the LLNL Ultra-short pulse (USP) laser. The targets were aluminum foils of thickness ranging from 250 A to 1250 A, heated with 120 fsec pulses of 400 nm light from the USP laser. The laser energy was approximately 0.2 Joules, focused to a 3 micron spot size for a peak intensity near 2 x 10{sup 19} W/cm{sup 2}. Ly{alpha} and He{alpha} lines were recorded using a 900 fsec x-ray streak camera. We calculate the effective ionization, recombination and emission rate coefficients including density effects for H-like and He-like aluminum ions using a collisional radiative model. We calculate time-dependent ion abundances using these effective ionization and recombination rate coefficients. The time-dependent electron temperature and density used in the calculation are based on an analytical model for the hydrodynamic expansion of the target foils. During the laser pulse the target is ionized. After the laser heating stops, the plasma begins to recombine. Using the calculated time dependent ion abundances and the effective emission rate coefficients, we calculate the time dependent Ly{alpha} and He{alpha} lines. The calculations reproduce the main qualitative features of the experimental spectra. (author)

  17. Two-dimensional long-living states of soliton type in order-disorder type ferroelectrics at spreading of an ultra-short laser impulse

    Science.gov (United States)

    Belonenko, M. B.; Sasov, A. S.

    2006-03-01

    In the present paper we found out two-dimensional long-living state of soliton type in order-disorder type ferroelectrics at spreading of an ultra-short laser impulse. We showed evolution in time of initial fuse polarization states to such formations depending on different parameters. We also searched influence of ferroelectric parameters on long-living state parameters.

  18. In-situ microscopy of front and rear side ablation processes in alkali aluminosilicate glass using ultra short pulsed laser radiation

    OpenAIRE

    Großmann, D.; Reininghaus, M.; Kalupka, C.; Jenne, M.; Kumkar, M.

    2017-01-01

    The visualization of the nonlinear absorption, the subsequent relaxation of excited states and the formation of defects enables the investigation of fundamental laser-material-interaction as well as the identification of process windows for micromachining of transparent materials with ultra short pulsed laser radiation. In this work, time resolved pump probe microscopy is applied to analyze the laser-material-interaction and to reduce damage inside the material during front- and rear side abl...

  19. Retina damage potential by ultra-short laser pulses in refractive surgery

    OpenAIRE

    Sander, Meike

    2013-01-01

    Since the beginning of the 1990s, laser in situ keratomileusis procedure (LASIK) has been successfully implemented in refractive eye surgery to correct ametropia. Nowadays this long time commanding treatment method is enhanced by implementing a new laser technology. It is based on correcting ametropia by applying ultrashort laser pulses in the fs-regime without using mechanical effect. Within this new technique the cutting process inside the cornea is achieved by a laser induced break...

  20. High energy electron and ion generation from thin target using ultra short table top laser

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, K.; Oishi, Y.; Fujii, T.; Nayuki, T.; Takizawa, Y. [Central Research Institute of Electric Power Industry, Tokyo (Japan); Sekiya, T; Okano, Y.; Hironaka, Y.; Nakamura, K. G.; Horioka, K.; Kondo, K. [Materials and Structures Laboratory, Toyko Institute of Technology, Tokyo (Japan)

    2003-07-01

    The influence of laser pulse duration on energetic electrons and protons generation was investigated using a Ti:sapphire laser. Energetic electrons with the temperature of 350 keV were produced by the irradiation of 90 mJ and 50 fs pulse onto a 30 {mu} m copper tape target. For ions, when laser pulse was changed by varying grating distance in the pulse compressor with keeping laser energy at constant value, the maximum proton energy was not changed so much in the region where laser pulse duration was between 55 fs and 400 fs and laser intensity was order of 10{sup 18} W/ cm{sup 2}. The maximum proton energy seems to more depend on the laser energy density on the target than laser intensity. When we evaluate the performance of ion acceleration using the value of E{sub p-max}/U{sub p} (the maximum proton energy normalized by the ponderomotive potential of the laser field), it increasing along with increasing of laser pulse duration.

  1. Propagation of an ultra-short, intense laser in a relativistic fluid

    Energy Technology Data Exchange (ETDEWEB)

    Ritchie, A.B.; Decker, C.D. [Lawrence Livermore National Lab., CA (United States)

    1997-12-31

    A Maxwell-relativistic fluid model is developed to describe the propagation of an ultrashort, intense laser pulse through an underdense plasma. The model makes use of numerically stabilizing fast Fourier transform (FFT) computational methods for both the Maxwell and fluid equations, and it is benchmarked against particle-in-cell (PIC) simulations. Strong fields generated in the wake of the laser are calculated, and the authors observe coherent wake-field radiation generated at harmonics of the plasma frequency due to nonlinearities in the laser-plasma interaction. For a plasma whose density is 10% of critical, the highest members of the plasma harmonic series begin to overlap with the first laser harmonic, suggesting that widely used multiple-scales-theory, by which the laser and plasma frequencies are assumed to be separable, ceases to be a useful approximation.

  2. Detection of calculus by laser-induced breakdown spectroscopy (LIBS) using an ultra-short pulse laser system (USPL)

    Science.gov (United States)

    Schelle, F.; Brede, O.; Krueger, S.; Oehme, B.; Dehn, C.; Frentzen, M.; Braun, A.

    2011-03-01

    The aim of this study was to assess the detection of calculus by Laser Induced Breakdown Spectroscopy (LIBS). The study was performed with an Nd:YVO4 laser, emitting pulses with a duration of 8 ps at a wavelength of 1064 nm. A repetition rate of 500 kHz at an average power of 5 W was used. Employing a focusing lense, intensities of the order of 1011 W/cm2 were reached on the tooth surface. These high intensities led to the generation of a plasma. The light emitted by the plasma was collimated into a fibre and then analyzed by an echelle spectroscope in the wavelength region from 220 nm - 900 nm. A total number of 15 freshly extracted teeth was used for this study. For each tooth the spectra of calculus and cementum were assessed separately. Comprising all single measurements median values were calculated for the whole spectrum, leading to two specific spectra, one for calculus and one for cementum. For further statistical analysis 28 areas of interest were defined as wavelength regions, in which the signal strength differed regarding the material. In 7 areas the intensity of the calculus spectrum differed statistically significant from the intensity of the cementum spectrum (p Laser Induced Breakdown Spectroscopy is well suited as method for a reliable diagnostic of calculus. Further studies are necessary to verify that LIBS is a minimally invasive method allowing a safe application in laser-guided dentistry.

  3. Material processing with ultra-short pulse lasers working in 2μm wavelength range

    Science.gov (United States)

    Voisiat, B.; Gaponov, D.; Gečys, P.; Lavoute, L.; Silva, M.; Hideur, A.; Ducros, N.; Račiukaitis, G.

    2015-03-01

    New wavelengths of laser radiation are of interest for material processing. Results of application of the all-fiber ultrashort pulsed laser emitting in 2 µm range, manufactured by Novae, are presented. Average output power was 4.35 W in a single-spatial-mode beam centered at the 1950 nm wavelength. Pulses duration was 40 ps, and laser operated at 4.2 MHz pulse repetition rate. This performance corresponded to 25 kW of pulse peak power and almost 1 µJ in pulse energy. Material processing was performed using three different focusing lenses (100, 30 and 18 mm) and mechanical stages for the workpiece translation. 2 µm laser radiation is strongly absorbed by some polymers. Swelling of PMMA surface was observed for scanning speed above 5 mm/s using the average power of 3.45 W focused with the 30 mm lens. When scanning speed was reduced below 4 mm/s, ablation of PMMA took place. The swelling of PMMA is a consequence of its melting due to absorbed laser power. Therefore, experiments on butt welding of PMMA and overlapping welding of PMMA with other polymers were performed. Stable joint was achieved for the butt welding of two PMMA blocks with thickness of 5 mm. The laser was used to cut a Kapton film on a paper carrier with the same set-up as previous. The cut width depended on the cutting speed and focusing optics. A perfect cut with a width of 11 µm was achieved at the translation speed of 60 mm/s.

  4. Printed organic smart devices characterized by ultra-short laser pulses

    DEFF Research Database (Denmark)

    Pastorelli, Francesco

    Resume: In this study, we demonstrate that nonlinear optical microscopy is a promising technique to characterize organic printed electronics. Using ultrashort laser pulses we stimulate two-photon absorption in a roll coated polymer semiconductor and map the resulting two-photon induced photolumin......Resume: In this study, we demonstrate that nonlinear optical microscopy is a promising technique to characterize organic printed electronics. Using ultrashort laser pulses we stimulate two-photon absorption in a roll coated polymer semiconductor and map the resulting two-photon induced...

  5. Optically transparent and durable Al2O3 coatings for harsh environments by ultra short pulsed laser deposition

    Science.gov (United States)

    Korhonen, Hannu; Syväluoto, Aki; Leskinen, Jari T. T.; Lappalainen, Reijo

    2018-01-01

    Nowadays, an environmental protection is needed for a number of optical applications in conditions quickly impairing the clarity of optical surfaces. Abrasion resistant optical coatings applied onto plastics are usually based on alumina or polysiloxane technology. In many applications transparent glasses and ceramics need a combination of abrasive and chemically resistant shielding or other protective solutions like coatings. In this study, we intended to test our hypothesis that clear and pore free alumina coating can be uniformly distributed on glass prisms by ultra short pulsed laser deposition (USPLD) technique to protect the sensitive surfaces against abrasives. Abrasive wear tests were carried out by the use of SiC emery paper using specified standard procedures. After the wear tests the measured transparencies of coated prisms turned out to be close those of the prisms before coating. The coating on sensitive surfaces consistently displayed enhanced wear resistance exhibiting still high quality, even after severe wear testing. Furthermore, the coating modified the surface properties towards hydrophobic nature in contrast to untreated prisms, which became very hydrophilic especially due to wear.

  6. Decoration of silica nanowires with gold nanoparticles through ultra-short pulsed laser deposition

    Science.gov (United States)

    Gontad, F.; Caricato, A. P.; Cesaria, M.; Resta, V.; Taurino, A.; Colombelli, A.; Leo, C.; Klini, A.; Manousaki, A.; Convertino, A.; Rella, R.; Martino, M.; Perrone, A.

    2017-10-01

    The ablation of a metal target at laser energy densities in the range of 1-10 TW/cm2 leads to the generation of nanoparticles (NP) of the ablated material. This aspect is of particular interest if the immobilization of NPs on three-dimensional (3D) substrates is necessary as for example in sensing applications. In this work the deposition of Au NP by irradiation of a Au bulk target with a sub-picosecond laser beam (500 fs; 248 nm; 10 Hz) on 2D (silica and Si(100)) and 3D substrates (silica nanowire forests) is reported for different number of laser pulses (500, 1000, 1500, 2000, 2500). A uniform coverage of small Au NPs (with a diameter of few nm) on both kinds of substrates has been obtained using a suitable number of laser pulses. The presence of spherical droplets, with a diameter ranging from tens of nm up to few μm was also detected on the substrate surface and their presence can be explained by the weak electron-phonon coupling of Au. The optical characterization of the samples on 2D and 3D substrates evidenced the surface plasmon resonance peak characteristic of the Au NPs although further improvements of the size-distribution are necessary for future applications in sensing devices.

  7. Oxygen-assisted multipass cutting of carbon fiber reinforced plastics with ultra-short laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Kononenko, T. V.; Komlenok, M. S.; Konov, V. I. [Natural Sciences Center, General Physics Institute, Vavilov str. 38, 119991 Moscow (Russian Federation); National Research Nuclear University, “MEPhI,” Kashirskoye shosse 31, 115409 Moscow (Russian Federation); Freitag, C. [Universität Stuttgart, Institut für Strahlwerkzeuge (IFSW), Pfaffenwaldring 43, 70569 Stuttgart (Germany); GSaME Graduate School of Excellence Advanced Manufacturing Engineering, Nobelstrasse 12, 70569 Stuttgart (Germany); Onuseit, V.; Weber, R.; Graf, T. [Universität Stuttgart, Institut für Strahlwerkzeuge (IFSW), Pfaffenwaldring 43, 70569 Stuttgart (Germany)

    2014-03-14

    Deep multipass cutting of bidirectional and unidirectional carbon fiber reinforced plastics (CFRP) with picosecond laser pulses was investigated in different static atmospheres as well as with the assistance of an oxygen or nitrogen gas flow. The ablation rate was determined as a function of the kerf depth and the resulting heat affected zone was measured. An assisting oxygen gas flow is found to significantly increase the cutting productivity, but only in deep kerfs where the diminished evaporative ablation due to the reduced laser fluence reaching the bottom of the kerf does not dominate the contribution of reactive etching anymore. Oxygen-supported cutting was shown to also solve the problem that occurs when cutting the CFRP parallel to the fiber orientation where a strong deformation and widening of the kerf, which temporarily slows down the process speed, is revealed to be typical for processing in standard air atmospheres.

  8. Two-phase zirconium boride thin film obtained by ultra-short pulsed laser ablation of a ZrB{sub 12} target

    Energy Technology Data Exchange (ETDEWEB)

    De Bonis, A., E-mail: angela.debonis@unibas.it [Dipartimento di Scienze, Università della Basilicata, Viale dell’Ateneo Lucano, 10 -85100 Potenza (Italy); Istituto di Metodologie Inorganiche e dei Plasmi, Consiglio Nazionale delle Ricerche, U.O.S. di Potenza, C.da Santa Loja, 85010 Tito Scalo, Potenza (Italy); Santagata, A. [Istituto di Metodologie Inorganiche e dei Plasmi, Consiglio Nazionale delle Ricerche, U.O.S. di Potenza, C.da Santa Loja, 85010 Tito Scalo, Potenza (Italy); Rau, J.V. [Istituto di Struttura della Materia, Consiglio Nazionale delle Ricerche, Via del Fosso del Cavaliere 100, 00133 Rome (Italy); Latini, A. [Università di Roma “La Sapienza”, Dipartimento di Chimica, Piazzale Aldo Moro, 5 -00185 Rome (Italy); Mori, T. [National Institute for Materials Science (NIMS) WPI Materials Nanoarchitectonics Center (MANA), Namiki 1-1, Tsukuba 305-0044 (Japan); Medici, L. [Istituto di Metodologie per le Analisi Ambientali, Consiglio Nazionale delle Ricerche, U.O.S. di Potenza, C.da Santa Loja, 85010 Tito Scalo, Potenza (Italy); Teghil, R. [Dipartimento di Scienze, Università della Basilicata, Viale dell’Ateneo Lucano, 10 -85100 Potenza (Italy)

    2013-10-15

    Two-phase zirconium boride thin films have been obtained by ultra-short pulsed laser ablation (PLA) of a zirconium dodecaboride (ZrB{sub 12}) target performed in vacuum. The ablation source was a frequency doubled (λ = 527 nm) Nd:glass laser with a pulse duration of 250 fs. Laser induced plasma has been studied by ICCD imaging and time and space resolved optical emission spectroscopy (OES), whereas the deposited films have been characterized by atomic force microscopy, scanning electron microscopy, X-Ray diffraction and micro-Raman spectroscopy. The film morphology and composition have been interpreted on the basis of the laser ablation mechanism.

  9. Particle characteristics of different materials after ultra-short pulsed laser (USPL) irradiation

    Science.gov (United States)

    Meister, Joerg; Schelle, Florian; Kowalczyk, Philip; Frentzen, Matthias

    2012-01-01

    The exposition of nanoparticles caused by laser application in dental health care is an open discussion. Based on the fact that nanoparticles can penetrate through the mucosa, the knowledge about particle characteristics after irradiation with an USPL is of high importance. Therefore, the aim of this study was to investigate the particle characteristics, especially the size of the ablated debris after USPL irradiation. The irradiation was carried out with an USP Nd:YVO4 laser with a center wavelength of 1064 nm. Based on the pulse duration of 8 ps and a pulse repetition rate of 500 kHz the laser emits an average power of 9 W. The materials investigated were dental tissues and dental restorative materials (composite and amalgam), ceramic and different metals (gold and aluminium). The samples were irradiated with a power density in the order of 300 GW/cm2 at distances of 5, 10, 15, and 20 mm. The debris was collected on an object plate. SEM pictures were used for analysis of the ablation debris. Depending on the irradiated material, we observed different kinds of structures: vitreous, flocculent, and pellet-like. The mean particle sizes were 10 x 10 up to 30 x 30 μm2. In addition, a cluster of ablated matter (nanometer range) distributed over the whole irradiated area was found. With increasing distances the cluster structure reduced from multi-layer to mono-layer clusters. Particle sizes in the micrometer and nanometer range were found after irradiation with an USPL. The nanoparticles create a cluster structure which is influenced by increasing distances.

  10. Accelerating Protons to Therapeutic Energies with Ultra-Intense Ultra-Clean and Ultra-Short Laser Pulses

    CERN Document Server

    Bulanov, Stepan S; Bychenkov, Valery Yu; Chvykov, Vladimir; Kalinchenko, Galina; Matsuoka, Takeshi; Rousseau, Pascal; Reed, Stephen; Yanovsky, Victor; Krushelnick, Karl; Litzenberg, Dale William; Maksimchuk, Anatoly

    2008-01-01

    Proton acceleration by high-intensity laser pulses from ultra-thin foils for hadron therapy is discussed. With the improvement of the laser intensity contrast ratio to 10-11 achieved on Hercules laser at the University of Michigan, it became possible to attain laser-solid interactions at intensities up to 1022 W/cm2 that allows an efficient regime of laser-driven ion acceleration from submicron foils. Particle-In-Cell (PIC) computer simulations of proton acceleration in the Directed Coulomb explosion regime from ultra-thin double-layer (heavy ions / light ions) foils of different thicknesses were performed under the anticipated experimental conditions for Hercules laser with pulse energies from 3 to 15 J, pulse duration of 30 fs at full width half maximum (FWHM), focused to a spot size of 0.8 microns (FWHM). In this regime heavy ions expand predominantly in the direction of laser pulse propagation enhancing the longitudinal charge separation electric field that accelerates light ions. The dependence of the ma...

  11. Ultra-short pulse delivery at high average power with low-loss hollow core fibers coupled to TRUMPF's TruMicro laser platforms for industrial applications

    Science.gov (United States)

    Baumbach, S.; Pricking, S.; Overbuschmann, J.; Nutsch, S.; Kleinbauer, J.; Gebs, R.; Tan, C.; Scelle, R.; Kahmann, M.; Budnicki, A.; Sutter, D. H.; Killi, A.

    2017-02-01

    Multi-megawatt ultrafast laser systems at micrometer wavelength are commonly used for material processing applications, including ablation, cutting and drilling of various materials or cleaving of display glass with excellent quality. There is a need for flexible and efficient beam guidance, avoiding free space propagation of light between the laser head and the processing unit. Solid core step index fibers are only feasible for delivering laser pulses with peak powers in the kW-regime due to the optical damage threshold in bulk silica. In contrast, hollow core fibers are capable of guiding ultra-short laser pulses with orders of magnitude higher peak powers. This is possible since a micro-structured cladding confines the light within the hollow core and therefore minimizes the spatial overlap between silica and the electro-magnetic field. We report on recent results of single-mode ultra-short pulse delivery over several meters in a lowloss hollow core fiber packaged with industrial connectors. TRUMPF's ultrafast TruMicro laser platforms equipped with advanced temperature control and precisely engineered opto-mechanical components provide excellent position and pointing stability. They are thus perfectly suited for passive coupling of ultra-short laser pulses into hollow core fibers. Neither active beam launching components nor beam trackers are necessary for a reliable beam delivery in a space and cost saving packaging. Long term tests with weeks of stable operation, excellent beam quality and an overall transmission efficiency of above 85 percent even at high average power confirm the reliability for industrial applications.

  12. The Application of Cryogenic Laser Physics to the Development of High Average Power Ultra-Short Pulse Lasers

    Directory of Open Access Journals (Sweden)

    David C. Brown

    2016-01-01

    Full Text Available Ultrafast laser physics continues to advance at a rapid pace, driven primarily by the development of more powerful and sophisticated diode-pumping sources, the development of new laser materials, and new laser and amplification approaches such as optical parametric chirped-pulse amplification. The rapid development of high average power cryogenic laser sources seems likely to play a crucial role in realizing the long-sought goal of powerful ultrafast sources that offer concomitant high peak and average powers. In this paper, we review the optical, thermal, thermo-optic and laser parameters important to cryogenic laser technology, recently achieved laser and laser materials progress, the progression of cryogenic laser technology, discuss the importance of cryogenic laser technology in ultrafast laser science, and what advances are likely to be achieved in the near-future.

  13. Relativistic electron mirrors from high intensity laser nanofoil interactions

    Energy Technology Data Exchange (ETDEWEB)

    Kiefer, Daniel

    2012-12-21

    The reflection of a laser pulse from a mirror moving close to the speed of light could in principle create an X-ray pulse with unprecedented high brightness owing to the increase in photon energy and accompanying temporal compression by a factor of 4γ{sup 2}, where γ is the Lorentz factor of the mirror. While this scheme is theoretically intriguingly simple and was first discussed by A. Einstein more than a century ago, the generation of a relativistic structure which acts as a mirror is demanding in many different aspects. Recently, the interaction of a high intensity laser pulse with a nanometer thin foil has raised great interest as it promises the creation of a dense, attosecond short, relativistic electron bunch capable of forming a mirror structure that scatters counter-propagating light coherently and shifts its frequency to higher photon energies. However, so far, this novel concept has been discussed only in theoretical studies using highly idealized interaction parameters. This thesis investigates the generation of a relativistic electron mirror from a nanometer foil with current state-of-the-art high intensity laser pulses and demonstrates for the first time the reflection from those structures in an experiment. To achieve this result, the electron acceleration from high intensity laser nanometer foil interactions was studied in a series of experiments using three inherently different high power laser systems and free-standing foils as thin as 3nm. A drastic increase in the electron energies was observed when reducing the target thickness from the micrometer to the nanometer scale. Quasi-monoenergetic electron beams were measured for the first time from ultrathin (≤5nm) foils, reaching energies up to ∝35MeV. The acceleration process was studied in simulations well-adapted to the experiments, indicating the transition from plasma to free electron dynamics as the target thickness is reduced to the few nanometer range. The experience gained from those

  14. Ultra-short pulse generation in a linear femtosecond fiber laser using a Faraday rotator mirror and semiconductor saturable absorber mirror

    Science.gov (United States)

    Hekmat, M. J.; Gholami, A.; Omoomi, M.; Abdollahi, M.; Bagheri, A.; Normohammadi, H.; Kanani, M.; Ebrahimi, A.

    2018-02-01

    An innovative method for obtaining ultra-short and perfectly stable femtosecond pulses in a linear erbium-doped fiber laser is proposed. A commercial semiconductor saturable absorber mirror and a standard Faraday rotator are used in both sides of the linear fiber optic laser configuration to shorten the pulse duration and suppress undesirable effects on the polarization state. The laser operation is investigated theoretically using a physical model and it is verified using experimental results. The main idea of this research is to apply a Faraday rotator mirror for pulse shortening purposes. For this reason, two types of Er-doped fiber optics with different group velocity dispersion parameters are used to achieve the optimum net group velocity dispersion in the cavity. Output results demonstrate good consistency between theory and experimental results. The output power of the linear oscillator is approximately 45 mW with 135 fs pulses at the 23.5 MHz repetition rate without any pulse compression.

  15. Determination of ultra-short laser induced damage threshold of KH{sub 2}PO{sub 4} crystal: Numerical calculation and experimental verification

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Jian [Center for Precision Engineering, School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001 (China); Department of Physics, The Ohio State University, 191 W. Woodruff Ave, Columbus, OH 43210 (United States); Chen, Mingjun, E-mail: chenmj@hit.edu.cn, E-mail: chowdhury.24@osu.edu; Wang, Jinghe; Xiao, Yong [Center for Precision Engineering, School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001 (China); Kafka, Kyle; Austin, Drake; Chowdhury, Enam, E-mail: chenmj@hit.edu.cn, E-mail: chowdhury.24@osu.edu [Department of Physics, The Ohio State University, 191 W. Woodruff Ave, Columbus, OH 43210 (United States)

    2016-03-15

    Rapid growth and ultra-precision machining of large-size KDP (KH{sub 2}PO{sub 4}) crystals with high laser damage resistance are tough challenges in the development of large laser systems. It is of high interest and practical significance to have theoretical models for scientists and manufacturers to determine the laser-induced damage threshold (LIDT) of actually prepared KDP optics. Here, we numerically and experimentally investigate the laser-induced damage on KDP crystals in ultra-short pulse laser regime. On basis of the rate equation for free electron generation, a model dedicated to predicting the LIDT is developed by considering the synergistic effect of photoionization, impact ionization and decay of electrons. Laser damage tests are performed to measure the single-pulse LIDT with several testing protocols. The testing results combined with previously reported experimental data agree well with those calculated by the model. By taking the light intensification into consideration, the model is successfully applied to quantitatively evaluate the effect of surface flaws inevitably introduced in the preparation processes on the laser damage resistance of KDP crystals. This work can not only contribute to further understanding of the laser damage mechanisms of optical materials, but also provide available models for evaluating the laser damage resistance of exquisitely prepared optical components used in high power laser systems.

  16. Advanced approaches to high intensity laser-driven ion acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Henig, Andreas

    2010-04-26

    Since the pioneering work that was carried out 10 years ago, the generation of highly energetic ion beams from laser-plasma interactions has been investigated in much detail in the regime of target normal sheath acceleration (TNSA). Creation of ion beams with small longitudinal and transverse emittance and energies extending up to tens of MeV fueled visions of compact, laser-driven ion sources for applications such as ion beam therapy of tumors or fast ignition inertial con finement fusion. However, new pathways are of crucial importance to push the current limits of laser-generated ion beams further towards parameters necessary for those applications. The presented PhD work was intended to develop and explore advanced approaches to high intensity laser-driven ion acceleration that reach beyond TNSA. In this spirit, ion acceleration from two novel target systems was investigated, namely mass-limited microspheres and nm-thin, free-standing diamond-like carbon (DLC) foils. Using such ultrathin foils, a new regime of ion acceleration was found where the laser transfers energy to all electrons located within the focal volume. While for TNSA the accelerating electric field is stationary and ion acceleration is spatially separated from laser absorption into electrons, now a localized longitudinal field enhancement is present that co-propagates with the ions as the accompanying laser pulse pushes the electrons forward. Unprecedented maximum ion energies were obtained, reaching beyond 0.5 GeV for carbon C{sup 6+} and thus exceeding previous TNSA results by about one order of magnitude. When changing the laser polarization to circular, electron heating and expansion were shown to be efficiently suppressed, resulting for the first time in a phase-stable acceleration that is dominated by the laser radiation pressure which led to the observation of a peaked C{sup 6+} spectrum. Compared to quasi-monoenergetic ion beam generation within the TNSA regime, a more than 40 times

  17. 3D laser printing by ultra-short laser pulses for micro-optical applications: towards telecom wavelengths

    Science.gov (United States)

    Ryu, Meguya; Mizeikis, Vygantas; Morikawa, Junko; Magallanes, Hernando; Brasselet, Etienne; Varapnickas, Simonas; Malinauskas, Mangirdas; Juodkazis, Saulius

    2017-08-01

    Three dimensional (3D) fast (laser oscillator is presented. Using sub-1 nJ pulse energies, optical vortex generators made of polymerised grating segments with an azimuthally changing orientation have been fabricated in SZ2080 resist; width of polymerised rods was 150 nm and period 0.6-1 μm. Detailed phase retardance analysis was carried out manually with Berek compensator (under a white light illumination) and using an equivalent principle by an automated Abrio implementation at 546 nm. Direct experimental measurements of retardance was required since the period of the grating was comparable (or larger) than the wavelength of visible light. By gold sputtering, transmissive optical vortex generators were turned into reflective ones with augmented retardance, Δn × h defined by the form birefringence, Δn, and the height h = 2d where d is the thickness of the polymerised structure. Retardance reached 315 nm as measured with Berek compensator at visible wavelengths. Birefringent phase delays of π (or λ/2 in wavelength) required for high purity vortex generators can be made based on the proposed approach. Optical vortex generators for telecom wavelengths with sub-wavelength patterns of azimuthally oriented gratings are amenable by direct laser polymerisation.

  18. Acceleration of electrons by high intensity laser radiation in a magnetic field

    OpenAIRE

    Melikian, Robert

    2013-01-01

    We consider the acceleration of electrons in vacuum by means of the circularly-polirized electromagnetic wave, propagating along a magnetic field. We show that the electron energy growth, when using ultra-short and ultra-intense laser pulses (10 ps, 10^{18} Bm/cm^2, CO_{2} laser) in the presence of a magnetic field, may reach up to the value 2,1 Gev. The growth of the electron energy is shown to increase proportionally with the increase of the laser intensity and the initial energy of the ele...

  19. Multifunctional gold nanorods for selective plasmonic photothermal therapy in pancreatic cancer cells using ultra-short pulse near-infrared laser irradiation

    Science.gov (United States)

    Patino, Tania; Mahajan, Ujjwal; Palankar, Raghavendra; Medvedev, Nikolay; Walowski, Jakob; Münzenberg, Markus; Mayerle, Julia; Delcea, Mihaela

    2015-03-01

    Gold nanorods (AuNRs) have attracted considerable attention in plasmonic photothermal therapy for cancer treatment by exploiting their selective and localized heating effect due to their unique photophysical properties. Here we describe a strategy to design a novel multifunctional platform based on AuNRs to: (i) specifically target the adenocarcinoma MUC-1 marker through the use of the EPPT-1 peptide, (ii) enhance cellular uptake through a myristoylated polyarginine peptide (MPAP) and (iii) selectively induce cell death by ultra-short near infrared laser pulses. We used a biotin-avidin based approach to conjugate EPPT-1 and MPAP to AuNRs. Dual-peptide (EPPT-1 + MPAP) labelled AuNRs showed a significantly higher uptake by pancreatic ductal adenocarcinoma cells when compared to their single peptide or avidin conjugated counterparts. In addition, we selectively induced cell death by ultra-short near infrared laser pulses in small target volumes (~1 μm3), through the creation of plasmonic nanobubbles that lead to the destruction of a local cell environment. Our approach opens new avenues for conjugation of multiple ligands on AuNRs targeting cancer cells and tumors and it is relevant for plasmonic photothermal therapy.Gold nanorods (AuNRs) have attracted considerable attention in plasmonic photothermal therapy for cancer treatment by exploiting their selective and localized heating effect due to their unique photophysical properties. Here we describe a strategy to design a novel multifunctional platform based on AuNRs to: (i) specifically target the adenocarcinoma MUC-1 marker through the use of the EPPT-1 peptide, (ii) enhance cellular uptake through a myristoylated polyarginine peptide (MPAP) and (iii) selectively induce cell death by ultra-short near infrared laser pulses. We used a biotin-avidin based approach to conjugate EPPT-1 and MPAP to AuNRs. Dual-peptide (EPPT-1 + MPAP) labelled AuNRs showed a significantly higher uptake by pancreatic ductal adenocarcinoma

  20. 3 W narrow-linewidth ultra-short wavelength operation near 1707 nm in thulium-doped silica fiber laser with bidirectional pumping

    Science.gov (United States)

    Xiao, Xusheng; Guo, Haitao; Yan, Zhijun; Wang, Hushan; Xu, Yantao; Lu, Min; Wang, Yishan; Peng, Bo

    2017-04-01

    We have developed an ultra-short wavelength operation of all-fiber Tm-doped laser system, in which the laser system was structured in a FBGs based linear cavity with FBG associated bidirectional pump mechanism at 1550 nm. The laser yielded 3.15 W of continuous-wave output at 1706.75 nm with a narrow-linewidth of 50 pm. A high reflectivity FBG (HR-FBG) at 1550 nm was used to reflect the residual pump light and achieve the bidirectional pump mechanism. The maximum slope efficiency was improved from 23.2% without HR-FBG to 42.1% with HR-FBG at 1550 nm and the lowest pump threshold was reduced from 1.6 to 0.8 W accordingly. In the experiment, we have also investigated the dependencies of the slope efficiencies and pump threshold of the laser versus the length of active fiber and reflectivity of the output mirror (FBG) in detail. It is indisputable that the development of 1.7 μm silicate fiber lasers with Watt-level output power will open up a number of promising application windows.

  1. Development of all solid-state, high average power ultra-short pulse laser for X-ray generation. High average power CPA system and wavefront control of ultra short laser pulse

    Energy Technology Data Exchange (ETDEWEB)

    Harayama, Sayaka; Akaoka, Katsuaki; Tei, Kazuyoku; Kato, Masaaki; Niwa, Yoshito; Maruyama, Yoichiro; Matoba, Toru; Arisawa, Takashi; Takuma, Hiroshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-03-01

    We developed a prototype CPA laser system which is pumped by a all solid-state Nd:YAG laser. In a preliminary experiment, the output energy of 52mJ before compression was obtained when the pumping energy was 250mJ. To compensate the wavefront distortion, an adaptive optics has been developed. By using this wavefront control system, the laser beam with the distortion of 0.15{lambda} was obtained. (author)

  2. Effects of high intensity laser therapy on pain and function of patients with chronic back pain.

    Science.gov (United States)

    Choi, Hyeun-Woo; Lee, Jongmin; Lee, Sangyong; Choi, Jioun; Lee, Kwansub; Kim, Byung-Kon; Kim, Gook-Joo

    2017-06-01

    [Purpose] This study examined the effects of High Intensity Laser Therapy on pain and function of patients with chronic back pain. [Subjects and Methods] This study evenly divided a total of 20 patients with chronic back pain into a conservative physical therapy group that received conservative physical therapy, and a high intensity laser therapy group that received High Intensity Laser Therapy after conservative physical therapy. All patients received the therapy three times a week for four weeks. For the high intensity laser therapy group, treatment was applied to the L1-L5 and S1 regions for 10 minutes by using a high intensity laser device while vertically maintaining the separation distance from handpiece to skin at approximately 1 cm. A visual analog scale was used to measure the pain and Oswestry Disability Index was used for functional evaluation. [Results] In a within-group comparison of the conservative physical therapy and high intensity laser therapy groups, both the visual analog scale and Oswestry Disability Index significantly decreased. In a between-group comparison after treatment, the high intensity laser therapy group showed a significantly lower visual analog scale and Oswestry Disability Index than the conservative physical therapy group. [Conclusion] High Intensity Laser Therapy can be an effective nonsurgical intervention method for reducing pain and helping the performance of daily routines of patients who have chronic back pain.

  3. Ultra-fast Movies Resolve Ultra-short Pulse Laser Ablation and Bump Formation on Thin Molybdenum Films

    Science.gov (United States)

    Domke, Matthias; Rapp, Stephan; Huber, Heinz

    For the monolithic serial interconnection of CIS thin film solar cells, 470 nm molybdenum films on glass substrates must be separated galvanically. The single pulse ablation with a 660 fs laser at a wavelength of 1053 nm is investigated in a fluence regime from 0.5 to 5.0 J/cm2. At fluences above 2.0 J/cm2 bump and jet formation can be observed that could be used for creating microstructures. For the investigation of the underlying mechanisms of the laser ablation process itself as well as of the bump or jet formation, pump probe microscopy is utilized to resolve the transient ablation behavior.

  4. High Intensity Laser Therapy (HILT) versus TENS and NSAIDs in low back pain: clinical study

    Science.gov (United States)

    Zati, Allesandro; Fortuna, Damiano; Valent, A.; Filippi, M. V.; Bilotta, Teresa W.

    2004-09-01

    Low back pain, caused by lumbar disc herniation, is prevalently treated with a conservative approach. In this study we valued the efficacy of High Intensity Laser Therapy (HILT), compared with accepted therapies such as TENS and NSAIDs. Laser therapy obtained similar results in the short term, but better clinical effect over time than TENS and NSAIDs. In conclusion high intensity laser therapy appears to be a interesting new treatment, worthy of further research.

  5. Diffraction Gratings for High-Intensity Laser Applications

    Energy Technology Data Exchange (ETDEWEB)

    Britten, J

    2008-01-23

    The scattering of light into wavelength-dependent discrete directions (orders) by a device exhibiting a periodic modulation of a physical attribute on a spatial scale similar to the wavelength of light has been the subject of study for over 200 years. Such a device is called a diffraction grating. Practical applications of diffraction gratings, mainly for spectroscopy, have been around for over 100 years. The importance of diffraction gratings in spectroscopy for the measurement of myriad properties of matter can hardly be overestimated. Since the advent of coherent light sources (lasers) in the 1960's, applications of diffraction gratings in spectroscopy have further exploded. Lasers have opened a vast application space for gratings, and apace, gratings have enabled entirely new classes of laser systems. Excellent reviews of the history, fundamental properties, applications and manufacturing techniques of diffraction gratings up to the time of their publication can be found in the books by Hutley (1) and more recently Loewen and Popov (2). The limited scope of this chapter can hardly do justice to such a comprehensive subject, so the focus here will be narrowly limited to characteristics required for gratings suitable for high-power laser applications, and methods to fabricate them. A particular area of emphasis will be on maximally-efficient large-aperture gratings for short-pulse laser generation.

  6. Multi-energy ion implantation from high-intensity laser

    OpenAIRE

    Cutroneo Mariapompea; Torrisi Lorenzo; Ullschmied Jiri; Dudzak Roman

    2016-01-01

    The laser-matter interaction using nominal laser intensity above 1015 W/cm2 generates in vacuum non-equilibrium plasmas accelerating ions at energies from tens keV up to hundreds MeV. From thin targets, using the TNSA regime, plasma is generated in the forward direction accelerating ions above 1 MeV per charge state and inducing high-ionization states. Generally, the ion energies follow a Boltzmann-like distribution characterized by a cutoff at high energy and by a Coulomb-shift towards high ...

  7. Multi-energy ion implantation from high-intensity laser

    Directory of Open Access Journals (Sweden)

    Cutroneo Mariapompea

    2016-06-01

    Full Text Available The laser-matter interaction using nominal laser intensity above 1015 W/cm2 generates in vacuum non-equilibrium plasmas accelerating ions at energies from tens keV up to hundreds MeV. From thin targets, using the TNSA regime, plasma is generated in the forward direction accelerating ions above 1 MeV per charge state and inducing high-ionization states. Generally, the ion energies follow a Boltzmann-like distribution characterized by a cutoff at high energy and by a Coulomb-shift towards high energy increasing the ion charge state. The accelerated ions are emitted with the high directivity, depending on the ion charge state and ion mass, along the normal to the target surface. The ion fluencies depend on the ablated mass by laser, indeed it is low for thin targets. Ions accelerated from plasma can be implanted on different substrates such as Si crystals, glassy-carbon and polymers at different fluences. The ion dose increment of implanted substrates is obtainable with repetitive laser shots and with repetitive plasma emissions. Ion beam analytical methods (IBA, such as Rutherford backscattering spectroscopy (RBS, elastic recoil detection analysis (ERDA and proton-induced X-ray emission (PIXE can be employed to analyse the implanted species in the substrates. Such analyses represent ‘off-line’ methods to extrapolate and to character the plasma ion stream emission as well as to investigate the chemical and physical modifications of the implanted surface. The multi-energy and species ion implantation from plasma, at high fluency, changes the physical and chemical properties of the implanted substrates, in fact, many parameters, such as morphology, hardness, optical and mechanical properties, wetting ability and nanostructure generation may be modified through the thermal-assisted implantation by multi-energy ions from laser-generated plasma.

  8. Short-pulse high intensity laser thin foil interaction

    Science.gov (United States)

    Audebert, Patrick

    2003-10-01

    The technology of ultrashort pulse laser generation has progressed to the point that optical pulses larger than 10 J, 300 fs duration or shorter are routinely produced. Such pulses can be focused to intensities exceeding 10^18 W/cm^2. With high contrast pulses, these focused intensities can be used to heat solid matter to high temperatures with minimal hydrodynamic expansion, producing an extremely high energy-density state of matter for a short period of time. This high density, high temperature plasma can be studied by x-ray spectroscopy. We have performed experiments on thin foils of different elements under well controlled conditions at the 100 Terawatt laser at LULI to study the characteristics X-ray emission of laser heated solids. To suppress the ASE effect, the laser was frequency doubled. S-polarized light with a peak intensity of 10^19W/cm^2 was used to minimize resonance absorption. To decrease the effect of longitudinal temperature gradients very thin (800 μ) aluminum foil targets were used. We have also studied the effect of radial gradient by limiting the measured x-ray emission zone using 50μ or 100μ pinhole on target. The spectra, in the range 7-8Å, were recorded using a conical crystal spectrometer coupled to a 800 fs resolution streak camera. A Fourier Domain Interferometry (FDI) of the back of the foil was also performed providing a measurement of the hydrodynamic expansion as function of time for each shot. To simulate the experiment, we used the 1D hydrodynamic code FILM with a given set of plasma parameter (ρ, Te) as initial conditions. The X-ray emission was calculated by post processing hydrodynamic results with a collisional-radiative model which uses super-configuration average atomic data. The simulation reproduces the main features of the experimental time resolved spectrum.

  9. Ultra-short X-ray sources generated through laser-matter interaction and their applications; Sources de rayonnement X ultrabref generees par interaction laser-matiere et leurs applications

    Energy Technology Data Exchange (ETDEWEB)

    Rousse, A

    2004-04-15

    This work is dedicated to the sources of ultra-short X-rays. The K{sub {alpha}} source, the non-linear Thomson source, the betatron source and the X-{gamma} source are presented. We show that a pump-probe experiment where the pump is a laser excitation and the probe is the X-K{sub {alpha}} ultra-short radiation, can be used to study the dynamics of material structure with a time resolution of 100 femtosecond. We describe 2 applications that have been achieved in the field of solid physics by using the diffraction technique with a time resolution in the range of the femtosecond. The first application has permitted the observation and characterization of the ultra-quick solid-phase transition that occurs on the surface of a semiconductor crystal. The second experiment deals with the role of optical phonons in the antecedent processes that lead to such ultra-quick solid-phase transitions. (A.C.)

  10. Interaction of ultra-short ultra-intense laser pulses with under-dense plasmas; Interaction d'impulsions laser ultra-courtes et ultra-intenses avec des plasmas sous denses

    Energy Technology Data Exchange (ETDEWEB)

    Solodov, A

    2000-12-15

    Different aspects of interaction of ultra-short ultra-intense laser pulses with underdense plasmas are studied analytically and numerically. These studies can be interesting for laser-driven electron acceleration in plasma, X-ray lasers, high-order harmonic generation, initial confinement fusion with fast ignition. For numerical simulations a fully-relativistic particle code WAKE was used, developed earlier at Ecole Polytechnique. It was modified during the work on the thesis in the part of simulation of ion motion, test electron motion, diagnostics for the field and plasma. The studies in the thesis cover the problems of photon acceleration in the plasma wake of a short intense laser pulse, phase velocity of the plasma wave in the Self-Modulated Laser Wake-Field Accelerator (SM LWFA), relativistic channeling of laser pulses with duration of the order of a plasma period, ion dynamics in the wake of a short intense laser pulse, plasma wave breaking. Simulation of three experiments on the laser pulse propagation in plasma and electron acceleration were performed. Among the main results of the thesis, it was found that reduction of the plasma wave phase velocity in the SM LWFA is crucial for electron acceleration, only if a plasma channel is used for the laser pulse guiding. Self-similar structures describing relativistic guiding of short laser pulses in plasmas were found and relativistic channeling of initially Gaussian laser pulses of a few plasma periods in duration was demonstrated. It was shown that ponderomotive force of a plasma wake excited by a short laser pulse forms a channel in plasma and plasma wave breaking in the channel was analyzed in detail. Effectiveness of electron acceleration by the laser field and plasma wave was compared and frequency shift of probe laser pulses by the plasma waves was found in conditions relevant to the current experiments. (author)

  11. Tenfold enhancement of MeV Proton generation by a moderate ultra-short laser interaction with H2O nano-wire targets

    CERN Document Server

    Zigler, A; Bruner, N; Schleifer, E; Eisenmann, S; Henis, Z; Botton, M; Pikuz, S A; Faenov, A Y; Gordon, D; Sprangle, P

    2010-01-01

    Compact sources of high energy protons (50-500MeV) are expected to be key technology in a wide range of scientific applications. Particularly promising is the target normal sheath acceleration (TNSA) scheme, holding record level of 67MeV protons generated by a peta-Watt laser. In general, laser intensity exceeding 10^18 W/cm2 is required to produce MeV level protons. Enhancing the energy of generated protons using compact laser sources is very attractive task nowadays. Recently, nano-scale targets were used to accelerate ions. Here we report on the first generation of 5.5-7.5MeV protons by modest laser intensities (4.5 x 10^17 W/cm2) interacting with H2O nano-wires (snow) deposited on a Sapphire substrate. In this setup, the plasma near the tip of the nano-wire is subject to locally enhanced laser intensity with high spatial gradients, and confined charge separation is obtained. Electrostatic fields of extremely high intensities are produced, and protons are accelerated to MeV-level energies. Nano-wire engine...

  12. ANALYSIS AND MITIGATION OF X-RAY HAZARD GENERATED FROM HIGH INTENSITY LASER-TARGET INTERACTIONS

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, R.; Liu, J.C.; Prinz, A.A.; Rokni, S.H.; Woods, M.; Xia, Z.; /SLAC

    2011-03-21

    Interaction of a high intensity laser with matter may generate an ionizing radiation hazard. Very limited studies have been made, however, on the laser-induced radiation protection issue. This work reviews available literature on the physics and characteristics of laser-induced X-ray hazards. Important aspects include the laser-to-electron energy conversion efficiency, electron angular distribution, electron energy spectrum and effective temperature, and bremsstrahlung production of X-rays in the target. The possible X-ray dose rates for several femtosecond Ti:sapphire laser systems used at SLAC, including the short pulse laser system for the Matter in Extreme Conditions Instrument (peak power 4 TW and peak intensity 2.4 x 10{sup 18} W/cm{sup 2}) were analysed. A graded approach to mitigate the laser-induced X-ray hazard with a combination of engineered and administrative controls is also proposed.

  13. Postionisation of a spatially nonuniform plasma plume under high-intensity femtosecond laser irradiation

    Science.gov (United States)

    Krestovskikh, D. A.; Ivanov, K. A.; Tsymbalov, I. N.; Shulyapov, S. A.; Bukin, V. V.; Volkov, R. V.; Rupasov, A. A.; Savel'ev, A. B.

    2017-02-01

    The plasma plume formed by a high-power nanosecond laser pulse on the surface of solid targets as well as the plume parameters after its irradiation by a high-intensity femtosecond laser pulse are investigated by optical diagnostic techniques. Two-dimensional patterns of the electron plasma density are reconstructed from experimentally recorded interferograms at different stages of plasma evolution. It is shown that the interaction of the high-intensity femtosecond radiation with the plasma cloud is accompanied by the field ionisation of atoms and ions as well as by a significant increase in the electron density throughout the interaction volume. Presented at ECLIM2016 (Moscow, 18-23 September 2016).

  14. High Intensity Laser Power Beaming Architecture for Space and Terrestrial Missions

    Science.gov (United States)

    Nayfeh, Taysir; Fast, Brian; Raible, Daniel; Dinca, Dragos; Tollis, Nick; Jalics, Andrew

    2011-01-01

    High Intensity Laser Power Beaming (HILPB) has been developed as a technique to achieve Wireless Power Transmission (WPT) for both space and terrestrial applications. In this paper, the system architecture and hardware results for a terrestrial application of HILPB are presented. These results demonstrate continuous conversion of high intensity optical energy at near-IR wavelengths directly to electrical energy at output power levels as high as 6.24 W from the single cell 0.8 cm2 aperture receiver. These results are scalable, and may be realized by implementing receiver arraying and utilizing higher power source lasers. This type of system would enable long range optical refueling of electric platforms, such as MUAV s, airships, robotic exploration missions and provide power to spacecraft platforms which may utilize it to drive electric means of propulsion.

  15. Simulation on interaction of a ultra short-pulse intense laser with foil. Proton acceleration with sub Peta-watt laser

    Energy Technology Data Exchange (ETDEWEB)

    Ueshima, Yutaka [Advanced Photon Research Center, Kansai Research Establishment, Japan Atomic Energy Research Inst., Neyagawa, Osaka (Japan); Sentoku, Yasuhiko [Institute for Laser Technology, Suita, Osaka (Japan); Kishimoto, Yasuaki [Dept. of Fusion Plasma Research, Naka Fusion Research Establishment, Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan)

    2000-03-01

    Proton and ion acceleration by sub Peta-watt laser radiation in overdense plasmas, especially for deformed thin foils, is studied with 2D3V-PIC (Particle in Cell) numerical simulations. It is found that the target and pulse shape design is important for the acceleration of the charged particles. When a superintense laser pulse interacts with a thin slab of ablative overdense plasma formed by the pre-pulse of the laser, its pondermotive pressure blows all the electrons away from a finite diameter spot on the slab. Resultingly, the absorption efficiency of the laser is larger than 50%, but ion acceleration efficiency is small in the case of the material composed of atoms of large mass number, for example, Al. When the surface of the target is coated with a rigid solid or clusters, are accelerated efficiently and ions gain energies as high as 100 MeV. If hydrogen is coated on the back of the thin Al foil, due to the Coulomb explosion of ions, protons are accelerated more efficiently than the hydrogen foil. (author)

  16. Analysis of induced stress on materials exposed to laser-plasma radiation during high-intensity laser experiments

    Science.gov (United States)

    Scisciò, M.; Barberio, M.; Liberatore, C.; Veltri, S.; Laramée, A.; Palumbo, L.; Legaré, F.; Antici, P.

    2017-11-01

    In this work, we investigate the damage produced in materials when exposed to a laser-generated plasma. The plasma was generated by interaction of a high-intensity laser with Oxygen. We demonstrate that the stress induced on the target surface of a Tantalum target (typical materials used as Plasma Facing Material) after 10 h of plasma exposure is equivalent to the stress induced during 1 h of conventional laser ablation using a pulsed 0.5 J laser. In both cases we obtain a surface erosion in the tens of μm, and a change in the surface roughness in the tens of nm for the stressed materials. The erosion rate of 1 nm/s, explained in terms of surface fragmentation at thermodynamic equilibrium, generates a slow damage to the materials exposed to the plasma. Our method allows indicating safety parameters for the maintenance of materials used in high-intensity laser experiments.

  17. High-intensity laser-accelerated ion beam produced from cryogenic micro-jet target

    Science.gov (United States)

    Gauthier, M.; Kim, J. B.; Curry, C. B.; Aurand, B.; Gamboa, E. J.; Göde, S.; Goyon, C.; Hazi, A.; Kerr, S.; Pak, A.; Propp, A.; Ramakrishna, B.; Ruby, J.; Willi, O.; Williams, G. J.; Rödel, C.; Glenzer, S. H.

    2016-11-01

    We report on the successful operation of a newly developed cryogenic jet target at high intensity laser-irradiation. Using the frequency-doubled Titan short pulse laser system at Jupiter Laser Facility, Lawrence Livermore National Laboratory, we demonstrate the generation of a pure proton beam a with maximum energy of 2 MeV. Furthermore, we record a quasi-monoenergetic peak at 1.1 MeV in the proton spectrum emitted in the laser forward direction suggesting an alternative acceleration mechanism. Using a solid-density mixed hydrogen-deuterium target, we are also able to produce pure proton-deuteron ion beams. With its high purity, limited size, near-critical density, and high-repetition rate capability, this target is promising for future applications.

  18. High-intensity laser-accelerated ion beam produced from cryogenic micro-jet target

    Energy Technology Data Exchange (ETDEWEB)

    Gauthier, M., E-mail: maxence.gauthier@stanford.edu; Kim, J. B.; Curry, C. B.; Gamboa, E. J.; Göde, S.; Propp, A.; Glenzer, S. H. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Aurand, B.; Willi, O. [Heinrich-Heine-University Düsseldorf, Düsseldorf (Germany); Goyon, C.; Hazi, A.; Pak, A.; Ruby, J.; Williams, G. J. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Kerr, S. [University of Alberta, Edmonton, Alberta T6G 1R1 (Canada); Ramakrishna, B. [Indian Institute of Technology, Hyderabad (India); Rödel, C. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Friedrich-Schiller-University Jena, Jena (Germany)

    2016-11-15

    We report on the successful operation of a newly developed cryogenic jet target at high intensity laser-irradiation. Using the frequency-doubled Titan short pulse laser system at Jupiter Laser Facility, Lawrence Livermore National Laboratory, we demonstrate the generation of a pure proton beam a with maximum energy of 2 MeV. Furthermore, we record a quasi-monoenergetic peak at 1.1 MeV in the proton spectrum emitted in the laser forward direction suggesting an alternative acceleration mechanism. Using a solid-density mixed hydrogen-deuterium target, we are also able to produce pure proton-deuteron ion beams. With its high purity, limited size, near-critical density, and high-repetition rate capability, this target is promising for future applications.

  19. Radiation Dose Measurement for High-Intensity Laser Interactions with Solid Targets at SLAC

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Taiee [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-09-25

    A systematic study of photon and neutron radiation doses generated in high-intensity laser-solid interactions is underway at SLAC National Accelerator Laboratory. We found that these laser-solid experiments are being performed using a 25 TW (up to 1 J in 40 fs) femtosecond pulsed Ti:sapphire laser at the Linac Coherent Light Source’s (LCLS) Matter in Extreme Conditions (MEC) facility. Additionally, radiation measurements were performed with passive and active detectors deployed at various locations inside and outside the target chamber. Results from radiation dose measurements for laser-solid experiments at SLAC MEC in 2014 with peak intensity between 1018 to 7.1x1019 W/cm2 are presented.

  20. Proton radiography of relativistic magnetic reconnection driven by ultra-high intensity lasers

    Science.gov (United States)

    Campbell, Paul T.; Raymond, A.; Palmer, C. A. J.; Ma, Y.; Chen, H.; Katzir, Y.; Mileham, C.; Nilson, P. M.; Ridgers, C. P.; Thomas, A. G. R.; Tubman, E. R.; Wei, M. S.; Williams, G. J.; Woolsey, N.; Willingale, L.; Krushelnick, K.

    2017-10-01

    In recent experiments conducted with the OMEGA-EP laser facility at LLE and the Vulcan laser at RAL, proton radiography was used to observe in detail the magnetic field dynamics associated with magnetic reconnection driven by ultra-high intensity, short pulse lasers. Two configurations were investigated: one with two short pulses focused on target in close proximity and another with a short pulse fired near a relatively slowly evolving long pulse produced plasma. The proton radiography results, along with x-ray imaging and angularly resolved electron spectra will be presented. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-0002727.

  1. Sub-picosecond snapshots of fast electrons from high intensity laser-matter interactions.

    Science.gov (United States)

    Pompili, R; Anania, M P; Bisesto, F; Botton, M; Castellano, M; Chiadroni, E; Cianchi, A; Curcio, A; Ferrario, M; Galletti, M; Henis, Z; Petrarca, M; Schleifer, E; Zigler, A

    2016-12-26

    The interaction of a high-intensity short-pulse laser with thin solid targets produces electron jets that escape the target and positively charge it, leading to the formation of the electrostatic potential that in turn governs the ion acceleration. The typical timescale of such phenomena is on the sub-picosecond level. Here we show, for the first time, temporally-resolved measurements of the first released electrons that escaped from the target, so-called fast electrons. Their total charge, energy and temporal profile are provided by means of a diagnostics based on Electro-Optical Sampling with temporal resolution below 100 fs.

  2. Optical Frequency Optimization of a High Intensity Laser Power Beaming System Utilizing VMJ Photovoltaic Cells

    Science.gov (United States)

    Raible, Daniel E.; Dinca, Dragos; Nayfeh, Taysir H.

    2012-01-01

    An effective form of wireless power transmission (WPT) has been developed to enable extended mission durations, increased coverage and added capabilities for both space and terrestrial applications that may benefit from optically delivered electrical energy. The high intensity laser power beaming (HILPB) system enables long range optical 'refueling" of electric platforms such as micro unmanned aerial vehicles (MUAV), airships, robotic exploration missions and spacecraft platforms. To further advance the HILPB technology, the focus of this investigation is to determine the optimal laser wavelength to be used with the HILPB receiver, which utilizes vertical multi-junction (VMJ) photovoltaic cells. Frequency optimization of the laser system is necessary in order to maximize the conversion efficiency at continuous high intensities, and thus increase the delivered power density of the HILPB system. Initial spectral characterizations of the device performed at the NASA Glenn Research Center (GRC) indicate the approximate range of peak optical-to-electrical conversion efficiencies, but these data sets represent transient conditions under lower levels of illumination. Extending these results to high levels of steady state illumination, with attention given to the compatibility of available commercial off-the-shelf semiconductor laser sources and atmospheric transmission constraints is the primary focus of this paper. Experimental hardware results utilizing high power continuous wave (CW) semiconductor lasers at four different operational frequencies near the indicated band gap of the photovoltaic VMJ cells are presented and discussed. In addition, the highest receiver power density achieved to date is demonstrated using a single photovoltaic VMJ cell, which provided an exceptionally high electrical output of 13.6 W/sq cm at an optical-to-electrical conversion efficiency of 24 percent. These results are very promising and scalable, as a potential 1.0 sq m HILPB receiver of

  3. Photon dose produced by a high-intensity laser on a solid target

    Science.gov (United States)

    Compant La Fontaine, A.

    2014-08-01

    When a high-intensity laser pulse hits a solid target, its pedestal creates a preplasma. The interaction of the main laser pulse, linearly polarized, with this preplasma produces relativistic electrons. These electrons subsequently penetrate inside the target, with high atomic number, and produce bremsstrahlung emission, which constitutes an x-ray source that may be used in various applications such as radiography of high area density objects, photonuclear studies or positron production. This x-ray source is mainly defined by its photon dose, which depends upon the laser, preplasma and target characteristics. In new facilities the radioprotection layout design can be obtained by numerical simulations, which are somewhat tedious. A simple model giving the photon dose per laser energy unit is obtained by using the mean bremsstrahlung cross section of electrons interacting with the atoms of the conversion target. It is expressed versus the fraction ηel of the laser energy absorbed into the forward hot electrons, their mean kinetic energy E, the photon lobe emission mean angular aperture \\bar{{\\theta}} and the target characteristics, i.e. thickness, element, atomic mass and atomic number. The parameters ηel, E and \\bar{{\\theta}} are analysed by applying the energy and momentum flux conservation laws during the laser-plasma interaction in the relativistic regime in an underdense and overdense plasma, including the hole-boring effect. In addition, these quantities are parametrized versus the normalized laser vector potential a0 and the preplasma scale length Lp by using a full set of numerical simulations, in the laser intensity domain 1018-1021 W cm-2 and preplasma scale length range 0.03-400µm. These simulations are done in two- and three-dimensional geometry with the CALDER particle-in-cell code, which computes the laser-plasma interaction, and with the MCNP Monte Carlo code, which calculates the bremsstrahlung emission. The present model is compared with the

  4. Gamma beams generation with high intensity lasers for two photon Breit-Wheeler pair production

    Science.gov (United States)

    D'Humieres, Emmanuel; Ribeyre, Xavier; Jansen, Oliver; Esnault, Leo; Jequier, Sophie; Dubois, Jean-Luc; Hulin, Sebastien; Tikhonchuk, Vladimir; Arefiev, Alex; Toncian, Toma; Sentoku, Yasuhiko

    2017-10-01

    Linear Breit-Wheeler pair creation is the lowest threshold process in photon-photon interaction, controlling the energy release in Gamma Ray Bursts and Active Galactic Nuclei, but it has never been directly observed in the laboratory. Using numerical simulations, we demonstrate the possibility to produce collimated gamma beams with high energy conversion efficiency using high intensity lasers and innovative targets. When two of these beams collide at particular angles, our analytical calculations demonstrate a beaming effect easing the detection of the pairs in the laboratory. This effect has been confirmed in photon collision simulations using a recently developed innovative algorithm. An alternative scheme using Bremsstrahlung radiation produced by next generation high repetition rate laser systems is also being explored and the results of first optimization campaigns in this regime will be presented.

  5. Proposed method for internal electron therapy based on high-intensity laser acceleration

    Science.gov (United States)

    Tepper, Michal; Barkai, Uri; Gannot, Israel

    2015-05-01

    Radiotherapy is one of the main methods to treat cancer. However, due to the propagation pattern of high-energy photons in tissue and their inability to discriminate between healthy and malignant tissues, healthy tissues may also be damaged, causing undesired side effects. A possible method for internal electron therapy, based on laser acceleration of electrons inside the patient's body, is suggested. In this method, an optical waveguide, optimized for high intensities, is used to transmit the laser radiation and accelerate electrons toward the tumor. The radiation profile can be manipulated in order to create a patient-specific radiation treatment profile by changing the laser characteristics. The propagation pattern of electrons in tissues minimizes the side effects caused to healthy tissues. A simulation was developed to demonstrate the use of this method, calculating the trajectories of the accelerated electron as a function of laser properties. The simulation was validated by comparison to theory, showing a good fit for laser intensities of up to 2×1020 (W/cm2), and was then used to calculate suggested treatment profiles for two tumor test cases (with and without penetration to the tumor). The results show that treatment profiles can be designed to cover tumor area with minimal damage to adjacent tissues.

  6. High-intensity laser for Ta and Ag implantation into different substrates for plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Cutroneo, M., E-mail: cutroneo@ujf.cas.cz [Nuclear Physics Institute, AS CR, 25068 Rez (Czech Republic); Mackova, A.; Malinsky, P. [Nuclear Physics Institute, AS CR, 25068 Rez (Czech Republic); Department of Physics, Faculty of Science, J.E. Purkinje University, Ceske mladeze 8, 400 96 Usti nad Labem (Czech Republic); Matousek, J. [Department of Physics, Faculty of Science, J.E. Purkinje University, Ceske mladeze 8, 400 96 Usti nad Labem (Czech Republic); Torrisi, L. [Department of Physics and Earth Sciences, Messina University, V.le F.S. d’Alcontres 31, 98166 S. Agata, Messina (Italy); Ullschmied, J. [Institute of Physics, ASCR, v.v.i., 182 21 Prague 8 (Czech Republic)

    2015-07-01

    High-intensity lasers generating non-equilibrium plasma, can be employed to accelerate ions in the keV–MeV region, useful for many applications. In the present work, we performed study of ion implantation into different substrates by using a high-intensity laser at the PALS laboratory in Prague. Multi-energy ions generated by plasma from Ta and Ag targets were implanted into polyethylene and metallic substrates (Al, Ti) at energies of tens of keV per charge state. The ion emission was monitored online using time-of-flight detectors and electromagnetic deflection systems. Rutherford Backscattering Spectrometry (RBS) was used to characterise the elemental composition in the implanted substrates by ion plasma emission and to provide the implanted ion depth profiling. These last measurements enable offline plasma characterisation and provide information on the useful potentiality of multi-ion species and multi-energy ion implantation into different substrates. XPS analysis gives information on the chemical bonds and their modifications in the first superficial implanted layers. The depth distributions of implanted Ta and Ag ions were compared with the theoretical ones achieved by using the SRIM-2012 simulation code.

  7. High-intensity laser for Ta and Ag implantation into different substrates for plasma diagnostics

    Science.gov (United States)

    Cutroneo, M.; Mackova, A.; Malinsky, P.; Matousek, J.; Torrisi, L.; Ullschmied, J.

    2015-07-01

    High-intensity lasers generating non-equilibrium plasma, can be employed to accelerate ions in the keV-MeV region, useful for many applications. In the present work, we performed study of ion implantation into different substrates by using a high-intensity laser at the PALS laboratory in Prague. Multi-energy ions generated by plasma from Ta and Ag targets were implanted into polyethylene and metallic substrates (Al, Ti) at energies of tens of keV per charge state. The ion emission was monitored online using time-of-flight detectors and electromagnetic deflection systems. Rutherford Backscattering Spectrometry (RBS) was used to characterise the elemental composition in the implanted substrates by ion plasma emission and to provide the implanted ion depth profiling. These last measurements enable offline plasma characterisation and provide information on the useful potentiality of multi-ion species and multi-energy ion implantation into different substrates. XPS analysis gives information on the chemical bonds and their modifications in the first superficial implanted layers. The depth distributions of implanted Ta and Ag ions were compared with the theoretical ones achieved by using the SRIM-2012 simulation code.

  8. Ablation properties of inorganic filler modified benzoxazine composite coating irradiated by high-intensity continuous laser

    Science.gov (United States)

    Xu, Feng; Ma, Zhuang; Li, Hezhang; Gao, Lihong; Wang, Fuchi

    2017-05-01

    Benzoxazine resin with good heat resistance, low combustion heat release and high char yield is a promising thermosetting resin. Meanwhile, research shows that the inorganic filler can effectively improve the thermodynamic property of the resin. It makes that the inorganic filler modified benzoxazine may have a potential application in laser ablation. The benzoxazine coating with and without inorganic filler ammonium polyphosphate, melamine and pentaerythritol (P-BOZ and BOZ) were prepared by brush and thermal curing method. The ablation properties of these coatings irradiated by high-intensity laser were investigated. The scanning electron microscope, Raman spectroscopy and thermal gravimetric analysis were used to characterize the micrographs, carbon layer structure and thermodynamic property of the sample. Results show that the composite coating has excellent thermal protective properties. The back temperature of 20 wt% P-BOZ coating under different parameter laser power (1000W/cm2, 5s; 1000W/cm2, 10s) are 40% lower than these of the BOZ coating and the 20 wt% P-BOZ has higher mass ablation rate. In the surface layer of the irradiated area, dense carbon layer is produced which reduces the absorb of the laser energy of the interior. In the interior of the sample, a large number of closed bell shaped holes are generated which are beneficial to obstruct the heat conduction.

  9. The study towards high intensity high charge state laser ion sources.

    Science.gov (United States)

    Zhao, H Y; Jin, Q Y; Sha, S; Zhang, J J; Li, Z M; Liu, W; Sun, L T; Zhang, X Z; Zhao, H W

    2014-02-01

    As one of the candidate ion sources for a planned project, the High Intensity heavy-ion Accelerator Facility, a laser ion source has been being intensively studied at the Institute of Modern Physics in the past two years. The charge state distributions of ions produced by irradiating a pulsed 3 J/8 ns Nd:YAG laser on solid targets of a wide range of elements (C, Al, Ti, Ni, Ag, Ta, and Pb) were measured with an electrostatic ion analyzer spectrometer, which indicates that highly charged ions could be generated from low-to-medium mass elements with the present laser system, while the charge state distributions for high mass elements were relatively low. The shot-to-shot stability of ion pulses was monitored with a Faraday cup for carbon target. The fluctuations within ±2.5% for the peak current and total charge and ±6% for pulse duration were demonstrated with the present setup of the laser ion source, the suppression of which is still possible.

  10. Monoenergetic proton emission from nuclear reaction induced by high intensity laser-generated plasmaa)

    Science.gov (United States)

    Torrisi, L.; Cavallaro, S.; Cutroneo, M.; Giuffrida, L.; Krasa, J.; Margarone, D.; Velyhan, A.; Kravarik, J.; Ullschmied, J.; Wolowski, J.; Szydlowski, A.; Rosinski, M.

    2012-02-01

    A 1016 W/cm2 Asterix laser pulse intensity, 1315 nm at the fundamental frequency, 300 ps pulse duration, was employed at PALS laboratory of Prague, to irradiate thick and thin primary CD2 targets placed inside a high vacuum chamber. The laser irradiation produces non-equilibrium plasma with deutons and carbon ions emission with energy of up to about 4 MeV per charge state, as measured by time-of-flight (TOF) techniques by using ion collectors and silicon carbide detectors. Accelerated deutons may induce high D-D cross section for fusion processes generating 3 MeV protons and 2.5 MeV neutrons, as measured by TOF analyses. In order to increase the mono-energetic proton yield, secondary CD2 targets can be employed to be irradiated by the plasma-accelerated deutons. Experiments demonstrated that high intensity laser pulses can be employed to promote nuclear reactions from which characteristic ion streams may be developed. Results open new scenario for applications of laser-generated plasma to the fields of ion sources and ion accelerators.

  11. Monoenergetic proton emission from nuclear reaction induced by high intensity laser-generated plasma.

    Science.gov (United States)

    Torrisi, L; Cavallaro, S; Cutroneo, M; Giuffrida, L; Krasa, J; Margarone, D; Velyhan, A; Kravarik, J; Ullschmied, J; Wolowski, J; Szydlowski, A; Rosinski, M

    2012-02-01

    A 10(16) W∕cm(2) Asterix laser pulse intensity, 1315 nm at the fundamental frequency, 300 ps pulse duration, was employed at PALS laboratory of Prague, to irradiate thick and thin primary CD(2) targets placed inside a high vacuum chamber. The laser irradiation produces non-equilibrium plasma with deutons and carbon ions emission with energy of up to about 4 MeV per charge state, as measured by time-of-flight (TOF) techniques by using ion collectors and silicon carbide detectors. Accelerated deutons may induce high D-D cross section for fusion processes generating 3 MeV protons and 2.5 MeV neutrons, as measured by TOF analyses. In order to increase the mono-energetic proton yield, secondary CD(2) targets can be employed to be irradiated by the plasma-accelerated deutons. Experiments demonstrated that high intensity laser pulses can be employed to promote nuclear reactions from which characteristic ion streams may be developed. Results open new scenario for applications of laser-generated plasma to the fields of ion sources and ion accelerators.

  12. Monoenergetic proton emission from nuclear reaction induced by high intensity laser-generated plasma

    Energy Technology Data Exchange (ETDEWEB)

    Torrisi, L. [INFN-LNS Via S. Sofia 44, 95123 Catania (Italy); Dip.to di Fisica, Universita di Messina, V.le F.S. D' Alcontres 31, 98166 S. Agata, Messina (Italy); Cavallaro, S.; Giuffrida, L. [INFN-LNS Via S. Sofia 44, 95123 Catania (Italy); Cutroneo, M. [Dip.to di Fisica, Universita di Messina, V.le F.S. D' Alcontres 31, 98166 S. Agata, Messina (Italy); Krasa, J.; Margarone, D.; Velyhan, A.; Ullschmied, J. [Institute of Physics, ASCR, v.v.i., 182 21 Prague 8 (Czech Republic); Kravarik, J. [Czech Technical University, Faculty of Electro-Engineering, Prague (Czech Republic); Wolowski, J.; Szydlowski, A.; Rosinski, M. [Institute of Plasma Physics and Laser Microfusion, IPPLM, 23 Hery Str., 01-497 Warsaw (Poland)

    2012-02-15

    A 10{sup 16} W/cm{sup 2} Asterix laser pulse intensity, 1315 nm at the fundamental frequency, 300 ps pulse duration, was employed at PALS laboratory of Prague, to irradiate thick and thin primary CD{sub 2} targets placed inside a high vacuum chamber. The laser irradiation produces non-equilibrium plasma with deutons and carbon ions emission with energy of up to about 4 MeV per charge state, as measured by time-of-flight (TOF) techniques by using ion collectors and silicon carbide detectors. Accelerated deutons may induce high D-D cross section for fusion processes generating 3 MeV protons and 2.5 MeV neutrons, as measured by TOF analyses. In order to increase the mono-energetic proton yield, secondary CD{sub 2} targets can be employed to be irradiated by the plasma-accelerated deutons. Experiments demonstrated that high intensity laser pulses can be employed to promote nuclear reactions from which characteristic ion streams may be developed. Results open new scenario for applications of laser-generated plasma to the fields of ion sources and ion accelerators.

  13. Deuterium–deuterium nuclear reaction induced by high intensity laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Torrisi, L., E-mail: lorenzo.torrisi@unime.it [INFN-LNS, Via S. Sofia 44, 95123 Catania (Italy); Dip.to di Fisica, Università di Messina, V.le F.S. D’Alcontres 31, 98166 S. Agata, Messina (Italy); Cavallaro, S.; Cutroneo, M.; Giuffrida, L. [INFN-LNS, Via S. Sofia 44, 95123 Catania (Italy); Dip.to di Fisica, Università di Messina, V.le F.S. D’Alcontres 31, 98166 S. Agata, Messina (Italy); Krasa, J.; Margarone, D.; Velyhan, A. [Institute of Physics, ASCR, v.v.i., 182 21 Prague 8 (Czech Republic); Kravarik, J. [Institute of Physics, ASCR, v.v.i., 182 21 Prague 8 (Czech Republic); Czech Technical University, Faculty of Electro-Engineering, Prague (Czech Republic); Ullschmied, J. [Institute of Physics, ASCR, v.v.i., 182 21 Prague 8 (Czech Republic); Wolowski, J.; Szydlowski, A.; Rosinski, M. [Institute of Plasma Physics and Laser Microfusion, IPPLM, 23 Hery Str., 01-497 Warsaw (Poland)

    2013-05-01

    A 10{sup 16} W/cm{sup 2} Asterix laser pulse intensity, 1315 nm wavelength, 300 ps pulse duration, was employed at PALS laboratory of Prague, to irradiate thick and thin primary CD{sub 2} targets placed into the high vacuum chamber. The laser irradiation produces non-equilibrium plasma with deuterons and carbon ions emission with energy up to about 4 MeV per charge state, as measured by time-of-flight (TOF) techniques by using ion collectors and silicon carbide detectors. Accelerated deuterium ions may induce high D–D cross section for fusion processes generating 3 MeV protons and 2.5 MeV neutrons, as measured by TOF analyses. In order to increase the mono-energetic proton yield, secondary CD{sub 2} targets can be availed to be irradiated by the plasma-accelerated deuterons. Experiments demonstrated that high intensity laser pulses can be employed to promote nuclear reactions from which characteristic ion streams may be developed. Results open new scenario for applications of laser-generated plasma to the fields of ion sources and ion accelerators.

  14. Deuterium-deuterium nuclear reaction induced by high intensity laser pulses

    Science.gov (United States)

    Torrisi, L.; Cavallaro, S.; Cutroneo, M.; Giuffrida, L.; Krasa, J.; Margarone, D.; Velyhan, A.; Kravarik, J.; Ullschmied, J.; Wolowski, J.; Szydlowski, A.; Rosinski, M.

    2013-05-01

    A 1016 W/cm2 Asterix laser pulse intensity, 1315 nm wavelength, 300 ps pulse duration, was employed at PALS laboratory of Prague, to irradiate thick and thin primary CD2 targets placed into the high vacuum chamber. The laser irradiation produces non-equilibrium plasma with deuterons and carbon ions emission with energy up to about 4 MeV per charge state, as measured by time-of-flight (TOF) techniques by using ion collectors and silicon carbide detectors. Accelerated deuterium ions may induce high D-D cross section for fusion processes generating 3 MeV protons and 2.5 MeV neutrons, as measured by TOF analyses. In order to increase the mono-energetic proton yield, secondary CD2 targets can be availed to be irradiated by the plasma-accelerated deuterons. Experiments demonstrated that high intensity laser pulses can be employed to promote nuclear reactions from which characteristic ion streams may be developed. Results open new scenario for applications of laser-generated plasma to the fields of ion sources and ion accelerators.

  15. X-Ray Optics Research for the Linac Coherent Light Source: Interaction of Ultra-Short X-Ray Laser Pulses with Optical Materials

    Energy Technology Data Exchange (ETDEWEB)

    Kuba, J; Wootton, A; Bionta, R M; Shepherd, R; Dunn, J; Smith, R F; London, R A; Shlyaptsev, V N; Bajt, S; Feit, M D; Levesque, R; Conant, R H; Fill, E E; Ditmire, T

    2002-07-24

    Free electron lasers operating in the 0.1 to 1.5 nm wavelength have been proposed for the Stanford Linear Accelerator Center and DESY (Germany). The unprecedented brightness and associated fluence predicted for pulses <300 fs pose new challenges for optical components. A criterion for optical component design is required, implying an understanding of x-ray-matter interactions at these extreme conditions. In our experimental effort, the extreme conditions are simulated by currently available sources ranging from optical lasers, through x-ray lasers (at 14.7 nm) down to K-alpha sources ({approx}0.15 nm). In this paper we present an overview of our research program, including (a) Results from the experimental campaign at a short pulse (100 fs-5 ps) power laser at 800 nm, (b) K-a experiments, and (c) Computer modeling and experimental project using a tabletop high brightness ps x-ray laser at the Lawrence Livermore National Laboratory.

  16. Simulations On Pair Creation In Collision Of γ-Beams Produced With High Intensity Lasers

    Science.gov (United States)

    Jansen, Oliver; Ribeyre, Xavier; D'Humieres, Emmanuel; Jaquier, Sophie; Tikhonchuk, Vladimir

    2017-10-01

    Direct production of electron-positron pairs in two photon collisions, the Breit-Wheeler process, is one of the most basic processes in the universe. However, this process has never been directly observed in the laboratory due to the lack of high intensity γ sources. For a feasibility study and for the optimisation of experimental set-ups we developed a high-performance tree-code. Different possible set-ups with MeV photon sources were discussed and compared using collision detection for huge number of particles in a quantum-electrodynamic regime. For this we implemented bounding volume hierarchies in a tree-like code structure. We applied this code on the question whether the Texas Petawatt laser could produce a significant number of pairs within the framework of the NSF project National Science Foundation under Grant No. 1632777.

  17. Formation of upconversion nanoparticles of 18%Yb:1%Er:NAYF4 by ultra-short pulse laser ablation in water

    Science.gov (United States)

    Gemini, Laura; Hernandez, Marie-Caroline; Kling, Rainer

    2016-03-01

    Pulsed laser ablation in liquid (PLAL) is nowadays gaining popularity as innovative, reliable and efficient technique to produce high-purity nanoparticles (NPs) of many inorganic and organic materials. In this context, attention has been recently focused on luminescent up-conversion NPs (UCNPs) which, being characterized by sharp emission bands in ultraviolet (UV)-to-near-infrared (NIR) range upon NIR irradiation, are in fact of great interest in many biological and biomedical applications. Moreover, with respect to organic dyes NPs and quantum dots, UCNPs show less toxicity, increased chemical stability, long-lifetime decays and lack of photo-bleaching. Our research focuses on generation of UCNPs of rare earth lanthanide-doped crystalline material, namely 18%Yb:1%Er:NAYF4, by PLAL in water. It is well known that optical properties of NPs strongly depend on their features, as for instance size and shape, which in turn may be controlled by laser ablation parameters. Therefore, two different laser sources are used for the ablation processes in order to find the set of laser parameter, i.e. pulse duration, laser fluence and repetition rate, for which the luminescence of UPNPs is optimized: (i) Amplitude Satsuma HP3 system: 330 fs pulse duration, 1030 wavelength and (ii) Eolite Hegoa system: 50 ps pulse duration, 1030 nm wavelength. UCNPs are finally characterized by spectrophotometer analyses to define emission range and intensity under NIR light and by transmission electron microscopy (TEM) to determine their size and shape.

  18. Development of a laser ion source for production of high-intensity heavy-ion beams

    Science.gov (United States)

    Kashiwagi, H.; Yamada, K.; Kurashima, S.

    2017-09-01

    A laser ion source has been developed as a high-intensity source for the ion implanter and the single pulsed beam of the azimuthally varying field cyclotron at TIARA. Highly charged beams of C5+ and C6+ ions and low-charged beams of heavy ions such as C, Al, Ti, Cu, Au, and Pt are required for the single-pulse acceleration in the cyclotron and for the ion implanter, respectively. In the vacuum chamber of the ion source, a target holder on a three-dimensional linear-motion stage provides a fresh surface for each laser shot. A large-sized target with a maximum size of 300 mm × 135 mm is mounted on the holder for long-term operation. The ion current (ion charge flux) in the laser-produced plasma is measured by a Faraday cup and time-of-flight spectra of each charge state are measured using a 90° cylindrical electrostatic analyzer just behind the Faraday cup. Carbon-plasma-generation experiments indicate that the source produces intense high- and low-charged pulsed ion beams. At a laser energy of 483 mJ (2.3 × 1013 W/cm2), average C6+ current of 13 mA and average C5+ current of 23 mA were obtained over the required time duration for single-pulse acceleration in the cyclotron (49 ns for C6+ and 80 ns for C5+). Furthermore, at 45 mJ (2.1 × 1012 W/cm2), an average C2+ current of 1.6 mA over 0.88 μs is obtained.

  19. Comparison of Square and Radial Geometries for High Intensity Laser Power Beaming Receivers

    Science.gov (United States)

    Raible, Daniel E.; Fast, Brian R.; Dinca, Dragos; Nayfeh, Taysir H.; Jalics, Andrew K.

    2012-01-01

    In an effort to further advance a realizable form of wireless power transmission (WPT), high intensity laser power beaming (HILPB) has been developed for both space and terrestrial applications. Unique optical-to-electrical receivers are employed with near infrared (IR-A) continuous-wave (CW) semiconductor lasers to experimentally investigate the HILPB system. In this paper, parasitic feedback, uneven illumination and the implications of receiver array geometries are considered and experimental hardware results for HILPB are presented. The TEM00 Gaussian energy profile of the laser beam presents a challenge to the effectiveness of the receiver to perform efficient photoelectric conversion, due to the resulting non-uniform illumination of the photovoltaic cell arrays. In this investigation, the geometry of the receiver is considered as a technique to tailor the receiver design to accommodate the Gaussian beam profile, and in doing so it is demonstrated that such a methodology is successful in generating bulk receiver output power levels reaching 25 W from 7.2 sq cm of photovoltaic cells. These results are scalable, and may be realized by implementing receiver arraying and utilizing higher power source lasers to achieve a 1.0 sq m receiver capable of generating over 30 kW of electrical power. This type of system would enable long range optical "refueling" of electric platforms, such as MUAV s, airships, robotic exploration missions and provide power to spacecraft platforms which may utilize it to drive electric means of propulsion. In addition, a smaller HILPB receiver aperture size could be utilized to establish a robust optical communications link within environments containing high levels of background radiance, to achieve high signal to noise ratios.

  20. Overview of inertial fusion and high-intensity laser plasma research in Europe

    Science.gov (United States)

    Tassart, J.

    2004-12-01

    Inertial fusion science is driven by 'the quest for ignition'. For many years, a 'conventional' route towards inertial fusion has been investigated using two different approaches: ignition by an inertial central hot spot could be obtained either through the direct or the indirect drive scheme. Both imply the use of a very large facility to operate the driver, which is a powerful laser in the current projects (LMJ in France as well as NIF in the US). The LMJ construction being on the way, a large amount of experimental and computational work is currently being done to deepen the understanding of ignition requirements. On the other hand, the so-called 'fast ignition' approach has led to an increasingly important amount of scientific work since it was proposed at the beginning of the 1990s. During the last several years (from the previous IFSA held in Kyoto in 2001), several PW-class high-intensity laser facilities have been built in Europe. In the meantime, a large number of interesting results related to fast electron and proton production have been obtained with the existing facilities. Observation of laser-irradiated solid targets has provided the first evidence of electron bunches separated by half the period of light. Nevertheless, target heating remains modest. On the other hand, multi-megaelectronvolt highly collimated electron beams have been produced by table-top lasers interacting with the low-density plasmas. They open the feasibility of a lot of applications: x-ray probe beams in plasma physics, biology, chemistry, injector for conventional accelerators, etc). Laser-produced proton beams is also a growing field, with a lot of promising applications: proton therapy, radio-isotope production, diagnostic for transient phenomena in laser-plasma interaction, etc. Inertial fusion research is fostered by a sustained effort of organization and coordination at the national level (the creation of an Institute for Lasers and Plasmas in France) as well as at the

  1. Studies of Ion Acceleration from Thin Solid-Density Targets on High-Intensity Lasers

    Science.gov (United States)

    Willis, Christopher R.

    experiment utilized new liquid crystal film targets developed at OSU, which may be formed at variable thicknesses from tens of nanometers to several microns. On this experiment, an optimum ion energy and flux was reached for targets of 600-900 nm, providing a peak proton energy of 24 MeV, and total ion flux of > 109 protons over 3.4 MeV from 5.5 J of laser energy at an intensity of 1 x 1020 W cm -2. The primary ion diagnostics for these two experiments are described in detail, including the analysis techniques needed to extract absolutely calibrated spatial and spectral distributions of the accelerated ions. Additionally, a new technique for target alignment is presented, providing repeatable target alignment on the micron scale. This allows for a repeatable laser intensity on target, allowing improved shot to shot consistency on high intensity experiments. In addition to these two experiments, work on the upgrade and characterization of the 400 TW Scarlet laser is discussed, including several calculations critical to the design and upgrade of the laser system, as well as prepulse characterization needed for experiments on thin targets.

  2. Determination of the nonlinear refractive index of multimode silica fiber with a dual-line ultra-short pulse laser source by using the induced grating autocorrelation technique.

    Science.gov (United States)

    Traore, Aboubakar; Lalanne, Elaine; Johnson, Anthony M

    2015-06-29

    We measured, within 6% accuracy, the nonlinear refractive index (n2) of 10 meter long multimode silica fiber of 17μm core diameter, using a modified induced grating autocorrelation technique (IGA). This measurement technique, based on time-delayed two beam coupling in a photorefractive crystal has been used to accurately measure n2 in short lengths of single mode fibers. For the first time to our knowledge, IGA is used to measure n2 of multimode fiber with a passively modelocked Nd:YVO4 laser operating with a dual-line near 1342 nm.

  3. Mid-infrared ultra-short mode-locked fiber laser utilizing topological insulator Bi2Te3 nano-sheets as the saturable absorber

    CERN Document Server

    Yin, Ke; Zheng, Xin; Yu, Hao; Cheng, Xiangai; Hou, Jing

    2015-01-01

    The newly-emergent two-dimensional topological insulators (TIs) have shown their unique electronic and optical properties, such as good thermal management, high nonlinear refraction index and ultrafast relaxation time. Their narrow energy band gaps predict their optical absorption ability further into the mid-infrared region and their possibility to be very broadband light modulators ranging from the visible to the mid-infrared region. In this paper, a mid-infrared mode-locked fluoride fiber laser with TI Bi2Te3 nano-sheets as the saturable absorber is presented. Continuous wave lasing, Q-switched and continuous-wave mode-locking (CW-ML) operations of the laser are observed sequentially by increasing the pump power. The observed CW-ML pulse train has a pulse repetition rate of 10.4 MHz, a pulse width of ~6 ps, and a center wavelength of 2830 nm. The maximum achievable pulse energy is 8.6 nJ with average power up to 90 mW. This work forcefully demonstrates the promising applications of two-dimensional TIs for ...

  4. Comparison between Epidural Block vs. High Intensity Laser Therapy for Controlling Chronic Low Back Pain

    Directory of Open Access Journals (Sweden)

    Badiozaman Radpay

    2016-01-01

    Full Text Available Background: Chronic low back pain is among a wide spread musculoskeletal conditions that is related to disability with high economy cost. There are several treatment modalities for controlling chronic low back pain (CLBP, among them high intensity laser therapy (HILT and epidural blocks (EB use more commonly. This study aimed to evaluate the benefits and hazards of each of these two methods.Materials and Methods: We designed a randomized controlled double blind study during 24 months.101 patients divided in 2 groups (52 in EB and 49 in HILT group. Pain intensity was assessed by using faces pain scales (FPS and LINKERT questionaries' before procedure and during one, four, 12, and 24 weeks after beginning the procedures.Results: There were no differences between two groups in FPS lumber tenderness, straight leg rising test (SLRT, paresthesia, deep tendon reflex (DTR, and imaging changes. Motor problems seem was less in HILT group comparing EB.Conclusion: This study showed both EB and HILT approaches can control the pain intensity and motor activities in CLBP patients. Future studies will clarify the precise importance of each these methods.

  5. Nonlinear evolutions of an ultra-intense ultra-short laser pulse in a rarefied plasma through a new quasi-static theory

    Science.gov (United States)

    Yazdanpanah, J.

    2018-02-01

    In this paper, we present a new description of self-consistent wake excitation by an intense short laser pulse, based on applying the quasi-static approximation (slow variations of the pulse-envelope) in the instantaneous Lorentz-boosted pulse co-moving frame (PCMF), and best verify our results through comparison with particle-in-cell simulations. According to this theory, the plasma motion can be treated perturbatively in the PCMF due to its high initial-velocity and produces a quasi-static wakefield in this frame. The pulse envelope, on the other hand, is governed by a form of the Schrödinger equation in the PCMF, in which the wakefield acts as an effective potential. In this context, pulse evolutions are characterized by local conservation laws resulted from this equation and subjected to Lorentz transformation into the laboratory frame. Using these conservation laws, precise formulas are obtained for spatiotemporal pulse evolutions and related wakefield variations at initial stages, and new equations are derived for instantaneous group velocity and carrier frequency. In addition, based on properties of the Schrödinger equation, spectral-evolutions of the pulse are described and the emergence of an anomalous dispersion branch with linear relation ω ≈ ck (c is the light speed) is predicted. Our results are carefully discussed versus previous publications and the significance of our approach is described by showing almost all suggestive definitions of group-velocity based on energy arguments fail to reproduce our formula and correctly describe the instantaneous pulse-velocity.

  6. Laser-matter interaction at high intensity and high temporal contrast; Interaction laser matiere a haut flux et fort contraste temporel

    Energy Technology Data Exchange (ETDEWEB)

    Doumy, G

    2006-01-15

    The continuous progress in the development of laser installations has already lead to ultra-short pulses capable of achieving very high focalized intensities (I > 10{sup 18} W/cm{sup 2}). At these intensities, matter presents new non-linear behaviours, due to the fact that the electrons are accelerated to relativistic speeds. The experimental access to this interaction regime on solid targets has long been forbidden because of the presence, alongside the femtosecond pulse, of a pedestal (mainly due to the amplified spontaneous emission (ASE) which occurs in the laser chain) intense enough to modify the state of the target. In this thesis, we first characterized, both experimentally and theoretically, a device which allows an improvement of the temporal contrast of the pulse: the Plasma Mirror. It consists in adjusting the focusing of the pulse on a dielectric target, so that the pedestal is mainly transmitted, while the main pulse is reflected by the overcritical plasma that it forms at the surface. The implementation of such a device on the UHI 10 laser facility (CEA Saclay - 10 TW - 60 fs) then allowed us to study the interaction between ultra-intense, high contrast pulses with solid targets. In a first part, we managed to generate and characterize dense plasmas resulting directly from the interaction between the main pulse and very thin foils (100 nm). This characterization was realized by using an XUV source obtained by high order harmonics generation in a rare gas jet. In a second part, we studied experimentally the phenomenon of high order harmonics generation on solid targets, which is still badly understood, but could potentially lead to a new kind of energetic ultra-short XUV sources. (author)

  7. EVALUATION OF THE THERAPEUTIC EFFICACY OF HIGH-INTENSITY PULSED-PERIODIC LASER RADIATION (CLINICAL AND EXPERIMENTAL OBSERVATIONS

    Directory of Open Access Journals (Sweden)

    V. V. Sokolov

    2016-01-01

    Full Text Available From the experience of clinical observations, we have shown a high therapeutic effectiveness of the medical laser KULON-MED in: cosmetics, non-cancer inflammatory diseases of the gastrointestinal tract and cancer (cancer of the stomach and colon as at different wavelengths, and with different types of photosensitizers. In the area of anti-tumor photodynamic therapy (PDT, based on experimental studies, we have showed the high antitumor (sarcoma S‑37 effectiveness of the laser (with the inhibition of tumor growth of up to 100% for repetitively pulsed irradiation mode, and for mode fractionation doses laser radiation. In addition, significant differences are shown in the effectiveness of anticancer PDT methods in the application of high-intensity lasers, continuous and pulsed caused fundamental properties of laser radiation characteristics – time structure of the radiation pulses. Thus, for the first time we have shown that the time of high-intensity laser pulses structure significantly affects therapeutic efficacy laser system, and hence on the mechanisms of interaction of laser radiation with biological tissue.

  8. Investigation of Photo Neutralization Efficiency of High Intensity H-Beam with Nd:YAG Laser for J-PARC

    CERN Document Server

    Tomisawa, T; Hasegawa, K; Kondo, Y; Oigawa, H; Sato, S; Ueno, A

    2005-01-01

    The photo neutralization method with Nd:YAG laser for negative hydrogen ions has been considered as an available candidate for beam intensity profile monitor and charge exchange procedure for Accelerator-Driven-System (ADS) in J-PARC. An electron of H-beam can be stripped by fast and intense Nd:YAG (1064nm) laser with non-destructive, and laser system have advantages of maintenance and radiation hardness in high intensity proton accelerators. In this paper, an experimental set-up and preliminary results of photo neutralization method for linac H- beam in KEK DTL1 are described.

  9. Efficacy of pulsed high-intensity laser therapy on pain, functional capacity, and gait in children with haemophilic arthropathy.

    Science.gov (United States)

    El-Shamy, Shamekh Mohamed; Abdelaal, Ashraf Abdelaal Mohamed

    2016-12-15

    The aim of this study was to evaluate the effects of pulsed high-intensity laser therapy (HILT) on pain, functional capacity, and gait in children with haemophilia. Thirty children with haemophilia type A with ages ranging from 9 to 13 years were selected for this study. They were assigned randomly, into two equal treatment groups. The laser group received the traditional physical therapy programme plus active laser (total energy of 1500 J through three phases/3 sessions/week), whereas the placebo group received the same physical therapy programme plus placebo laser over three consecutive months. Baseline and post-treatment assessments used the visual analogue scale (VAS) to evaluate pain, a 6-min walk test (6MWT) to evaluate functional capacity, and the GAITRite(®) system to evaluate gait parameters. Children in the laser group showed significant improvement in pain, functional capacity, and gait parameters compared to those in the placebo group (p capacity for the laser and placebo groups were 316.6 ± 35.27 and 288 ± 43.3 m, respectively. HILT is an effective modality in reducing pain, increasing functional capacity, and improving gait performance in children with haemophilic arthropathy. Implications for Rehabilitation Haemophilic arthropathy due to recurrent joint bleeding leads to physical, psychological, and socioeconomic problems in children with haemophilia and reduces their quality of life. Early physiotherapeutic interventions help to prevent and treat the sequelae of recurrent haemarthrosis. High-intensity laser therapy has been introduced as non-invasive and an effective physiotherapy modality for rapid pain control, with consequent improvement in children's quality of life. High-intensity laser therapy should be used as an adjunct to exercise programme in the rehabilitation of children with haemophilic arthropathy.

  10. Feasibility of laser-integrated high intensity focused ultrasound (HIFU) treatment for bladder tumors: in vitro study (Conference Presentation)

    Science.gov (United States)

    Nguyen, Van Phuc; Park, Suhyun; Oh, Junghwan; Kang, Hyun Wook

    2016-02-01

    Previous studies have shown that photothemal therapy combined with high intensity focused ultrasound (HIFU) can provide a promising method to achieve rapid thermal coagulation during surgical procedures. The current study investigated the feasibility of the laser-integrated high intensity focused ultrasound (HIFU) application to treat bladder tumors by enhancing thermal effects and therapeutic depth in vitro. To generate thermal coagulation, a single element HIFU transducer with a central frequency of 2.0 MHz was used to transmit acoustic energy to 15 fresh porcine bladders injected with an artificial tumor (100 µl gelatin and hemoglobin solution) in vitro. Simultaneously, an 80-W 532-nm laser system was also implemented to induce thermal necrosis in the targeted tissue. The intensity of 570 W/cm2 at the focus of HIFU and laser energy of 0.9 W were applied to all the samples for 40 s. The temperature rise increased up to about 1.6 or 3 folds (i.e., ΔT=32±3.8 K for laser-integrated HIFU, ΔT=20±6.5 K for HIFU only, and ΔT=11±5.6 K for laser only). The estimated lesion depth also increased by 1.3 and 2 folds during the dual-thermal treatment, in comparison with the treatment by either HIFU or laser. The results indicated that the laser-integrated HIFU treatment can be an efficient hyperthermic method for tumor coagulation.

  11. Theoretical investigation of external injection schemes for laser wakefield acceleration

    NARCIS (Netherlands)

    Luttikhof, M.J.H.

    2010-01-01

    This thesis reports on laser wakefield acceleration, a radically new approach for particle acceleration that builds on the huge electric fields that a plasma wave can provide. In this approach, an ultra-short laser pulse of high intensity is sent through a plasma. At sufficient intensity, the

  12. Prospects of odd and even harmonic generation by an atom in a high-intensity laser field

    Science.gov (United States)

    Bogatskaya, A. V.; Volkova, E. A.; Popov, A. M.

    2017-05-01

    A new approach for studying the spontaneous emission of an atomic system in the presence of a high-intensity laser field is used to study the process of harmonic generation. The analysis is based on consideration of quantum system interaction, with the quantized field modes being in the vacuum state, while the intense laser field is considered to be classically beyond perturbation theory. The numerical analysis of the emission from the single one-electron 1D atom irradiated by the femtosecond laser pulse of a Ti:Sa laser is discussed. It is demonstrated that not only odd, but also even harmonics can be emitted if the laser field is strong enough. The origin of the appearance of even harmonics is studied. The obtained results are compared with those found in the framework of the semiclassical approach that is widely used to study harmonic generation. It is found that the semiclassical approach is inapplicable in the strong-field limit.

  13. Generation of hard X-ray from solid target irradiated by UV high intensity ultrashort pulse laser

    CERN Document Server

    Tao Ye; Tang Xiu Zhang; Shan Yu Sheng; Wang Nai Yan

    2002-01-01

    Hard X-ray continuum generated from interaction of UV high intensity ultrashort pulse laser with solid target has been investigated by experiment. P-polarized light irradiating 5 mm Cu slab with 45 degree, the hard X-ray with energy of 200 keV has been detected. Fitting the experiment data by Maxwellian distribution, the temperature of hot electron is 67 keV. The experiment data are the results of combination of several absorption mechanisms

  14. HILL: The High-Intensity Laser Laboratory Core Team's Reply to Questions from the NNSA Experimental Facilities Panel

    Energy Technology Data Exchange (ETDEWEB)

    Albright, B J [Los Alamos National Laboratory

    2012-08-02

    Question 1 - The type of physics regimes that HILL can access for weapons studies is quite interesting. The question that arises for the proposal team is what priority does this type of experimental data have versus data that can be obtained with NIF, and Z. How does HILL rank in priority compared to MARIE 1.0 in terms of the experimental data it will provide? We reiterate that isochoric heating experiments to be conducted with HILL are complementary to the high energy density physics experiments at NIF and Z and uniquely access states of matter that neither other facility can access. It is our belief that HILL will enable several important questions, e.g., as related to mix morphology, radiation transfer from corrugated surfaces, and equations of state, to be run to ground through carefully diagnosed, 'unit-physics' experiments. Such experiments will substantially improve confidence in our computer models and provide a rigorous science basis for certification. Question 2 - A secondary question relates to the interests of LLNL and SNL in the physics that HILL can address. This should be spelled out clearly. I would like to see the other labs be part of the discussion regarding how important this capability would be if built. Both sister Labs have a keen interest in the physics enabled by high-intensity, high-energy lasers, as evinced by the Z Petawatt and NIF ARC upgrades to their signature facilities. LANL scientists have teamed with scientists from both Laboratories in high-intensity laser 'first experiments' envisioned for HILL and we fully intend to continue these profitable discussions going forward. In the preparation of the HILL proposal, feedback was solicited from the broader HEDP and weapons science communities. The consensus view was that HILL filled a critical gap and that there was a need for a facility like HILL to address outstanding questions in weapons science. It was recognized that co-location of HILL with a facility such as

  15. Characterization of high intensity Ni-like X-ray lasers and their application experiment

    Energy Technology Data Exchange (ETDEWEB)

    Tang, H.J.; Daido, H.; Suzuki, M. [Osaka Univ., Suita (Japan). Inst. of Laser Engineering; Japan Atomic Energy Research Inst., Kyoto (Japan). Advanced Photon Research Center; Yamagami, S.; Nagai, K.; Norimatsu, T.; Mima, K.; Yamanaka, T. [Osaka Univ., Suita (Japan). Inst. of Laser Engineering; Kato, Y.; Sasaki, A.; Hasegawa, N. [Japan Atomic Energy Research Inst., Kyoto (Japan). Advanced Photon Research Center; Wang, S.; Gu, Y.; Huang, G. [National Lab. on High Power Laser and Physics, Shanghai, SH (China); Carillon, A.; Ros, D.; Fourcade, P.; Jamelot, G. [Lab. de Spectroscopie Atomique et Ionique, Univ. Paris-Sud, Orsay (France); Joyeux, D.; Phalippou, D. [Lab. Charles Fabry, CNRS, Inst. d' Optique, Orsay (France); Murai, K. [Osaka National Research Inst., Ikeda, Osaka (Japan); Butzbach, R.; Uschmann, I.; Foerster, E. [IOQ, Friedrich-Schiller Univ., Jena (Germany); Namikawa, K.; Tai, R. [Tokyo Gakugei Univ., Koganei (Japan); Koike, F. [Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine; Takenaka, H. [NTT Advanced Technology, Musashino (Japan); Zhang, G. [Inst. of Applied Physics and Computational Mathematics, Beijing, BJ (China); Choi, I.W. [Korea Advanced Inst. of Science and Technology, Taejon (Korea)

    2001-07-01

    At the Institute of Laser Engineering, Osaka University, we have obtained Ni-like X-ray lasers of various atomic number elements, including many shorter wavelength Ni-like lasing lines around 5 nm. The saturated amplification of Ni-like Ag lasing line at the wavelength of 13.9 nm have been observed. Using these X-ray lasers, we are preparing the application experiments such as probing a laser-produced plasma with an X-ray laser interferometer. (orig.)

  16. Antimalarial Activity of Ultra-Short Peptides

    Directory of Open Access Journals (Sweden)

    María Yolanda Rios

    2009-12-01

    Full Text Available Ultra-short peptides 1-9 were designed and synthesized with phenylalanine, ornithine and proline amino acid residues and their effect on antimalarial activity was analyzed. On the basis of the IC50 data for these compounds, the effects of nature, polarity, and amino acid sequence on Plasmodium berghei schizont cultures were analyzed too. Tetrapeptides Phe-Orn-Phe-Orn (4 and Lys-Phe-Phe-Orn (5 showed a very important activity with IC50 values of 3.31 and 2.57 μM, respectively. These two tetrapeptides are candidates for subsequent in vivo assays and SARS investigations.

  17. Pair production by high intensity picosecond laser interacting with thick solid target at XingGuangIII

    Science.gov (United States)

    Wu, Yuchi; Dong, Kegong; Yan, Yonghong; Zhu, Bin; Zhang, Tiankui; Chen, Jia; Yu, Minghai; Tan, Fang; Wang, Shaoyi; Han, Dan; Lu, Feng; Gu, Yuqiu

    2017-06-01

    An experiment for pair production by high intensity laser irradiating thick solid targets is present. The experiment used picosecond beam of the XingGuangIII laser facility, with intensities up to several 1019 W/cm2, pulse durations about 0.8 ps and laser energies around 120 J. Pairs were generated from 1 mm-thick tantalum disk targets with different diameters from 1 mm to 10 mm. Energy spectra of hot electron from targetrear surface represent a Maxwellian distribution and obey a scaling of ∼(Iλ2)0.5. Large quantity of positrons were observed at the target rear normal direction with a yield up to 2.8 × 109 e+/sr. Owing to the target rear surface sheath field, the positrons behave as a quasi-monoenergetic beam with peak energy of several MeV. Our experiment shows that the peak energy of positron beam is inversely proportional to the target diameter.

  18. Modeling saturable absorption for ultra short X-ray pulses

    Energy Technology Data Exchange (ETDEWEB)

    Hatada, Keisuke, E-mail: keisuke.hatada@unicam.it [CNISM, Sezione di Fisica, Scuola di Scienze e Tecnologie, Universit‘a di Camerino, via Madonna delle Carceri 9, I-62032 Camerino (Italy); INFN, Laboratori Nazionali di Frascati, 00044 Frascati (Italy); Di Cicco, Andrea [CNISM, Sezione di Fisica, Scuola di Scienze e Tecnologie, Universit‘a di Camerino, via Madonna delle Carceri 9, I-62032 Camerino (Italy)

    2014-10-15

    Saturable absorption was recently observed in transmission measurements above the L{sub II,III} edge of pure Al thin films using ultra short X-ray pulses at a free-electron-laser (FEL) facility. The high fluence reachable by FEL pulses, the shortness of the pulse duration, and the typical lifetime of the excited state are all important factors enabling observation of the phenomenon. We devised a simplified theoretical approach describing the saturation phenomenon using a three-channel model containing ground, excited and relaxed states. This phenomenological model explicitly includes the interaction between the solid and photon field in a semi-classical way, and the resulting non-linear coupled equation is solved numerically. We successfully applied this model to recent experimental results obtained using FEL radiation.

  19. Optical observation of shock waves and cavitation bubbles in high intensity laser-induced shock processes.

    Science.gov (United States)

    Martí-López, L; Ocaña, R; Porro, J A; Morales, M; Ocaña, J L

    2009-07-01

    We report an experimental study of the temporal and spatial dynamics of shock waves, cavitation bubbles, and sound waves generated in water during laser shock processing by single Nd:YAG laser pulses of nanosecond duration. A fast ICCD camera (2 ns gate time) was employed to record false schlieren photographs, schlieren photographs, and Mach-Zehnder interferograms of the zone surrounding the laser spot site on the target, an aluminum alloy sample. We recorded hemispherical shock fronts, cylindrical shock fronts, plane shock fronts, cavitation bubbles, and phase disturbance tracks.

  20. Near-critical density target experiments for ion acceleration using high-intensity laser pulses

    Science.gov (United States)

    Kordell, Peter; Campbell, Paul; Maksimchuk, Anatoly; Willingale, Louise; Krushelnick, Karl

    2017-10-01

    The interaction of a short-duration, relativistic intensity laser pulse with a near-critical density plasma can produce a collisionless electrostatic shock capable of accelerating ions. This effect has already been demonstrated using CO2 laser systems (λ = 10 μm) where the specific plasma density profile enabled the acceleration of quasi-monoenergetic ion beams. We will present our experiments using the T-cubed laser system at the University of Michigan (λ = 1.053 μm , 6J, 400fs). Due to the shorter wavelength, typical of most relativistic intensity laser systems, a higher plasma density and shorter scalelengths are required to achieve the conditions for shock ion acceleration. The target design and characterization as well as preliminary experimental results will be presented. This work was supported by the DOE through Grant Number DE-SC0012327.

  1. Target Surface Area Effects on Hot Electron Dynamics from High Intensity Laser-Plasma Interactions

    Science.gov (United States)

    2016-08-19

    sheath field confinement on electron dynamics. X-ray emission due to energetic electrons was imaged using a aK imaging crystal. Electronswere observed to...laser conversion efficiency into particle andfield energy. Previous efforts tominimize this effect have primarily focused on small, isolated targets...leading to enhanced fields [12] improved conversion efficiency [13] and enhanced proton energies [14]with laser pulse durations of hundreds of fs

  2. Heating of heat-conducting targets by laser pulses with a high-intensity leading spike

    Science.gov (United States)

    Ageev, V. P.; Burdin, S. G.; Konov, V. I.; Uglov, S. A.; Chapliev, N. I.

    1983-04-01

    The results of an analysis of the solution of a one-dimensional heat conduction equation are used to study the specific features of the thermal effects of laser pulses with a leading spike on a target. Simple criteria are obtained for establishing the ability of a pulse to cause a given increase in the target surface temperature during the leading edge of a spike and also during the tail of the laser pulse. A study is made of the influence of the inhomogeneity of the distribution of surface heat sources on the realization of processes characterized by a threshold in respect of the temperature of the irradiated surface. The results obtained are compared with the experimental delay time in the process of initiation of an air breakdown plasma by interaction of CO2 laser pulses with a metal target.

  3. X-ray emission simulation from hollow atoms produced by high intensity laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Moribayashi, Kengo; Sasaki, Akira; Zhidkov, A. [Japan Atomic Energy Research Inst., Kansai Research Establishment, Neyagawa, Osaka (Japan); Suto, Keiko [Nara Women' s Univ., Graduate School of Human Culture, Nara (Japan); Kagawa, Takashi [Nara Women' s Univ., Department of Physics, Nara (Japan)

    2001-10-01

    We theoretically study the x-ray emission from hollow atoms produced by collisions of multiply charged ions accelerated by a short pulse laser with a solid or foil. By using the multistep-capture-and-loss (MSCL) model a high conversion efficiency to x-rays in an ultrafast atomic process is obtained. It is also proposed to apply this x-ray emission process to the x-ray source. For a few keV x-rays this x-ray source has a clear advantage. The number of x-ray photons increases as the laser energy becomes larger. For a laser energy of 10 J, the number of x-ray photons of 3x10{sup 11} is estimated. (author)

  4. Condensation of ablation plumes in the irradiation of metals by high-intensity nanosecond laser pulses at atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Kozadaev, K V [A.N. Sevchenko Institute of Applied Physical Problems, Belarusian State University, Minsk (Belarus)

    2016-01-31

    The Anisimov–Luk'yanchuk model is adapted for describing the condensation of vapour-plasma plumes produced in the irradiation of metal targets by high-intensity (10{sup 8} – 10{sup 10} W cm{sup -2}) nanosecond (10 – 100 ns) pulses at atmospheric pressure. The resultant data suggest that the initial stages of the development of metal ablation plumes correspond with a high degree of accuracy to the Zel'dovich–Raizer theory of dynamic condensation; however, at the stage of the ablation plume decay, the liquid-droplet phase is formed primarily by coalescence of 'nuclei'. (interaction of laser radiation with matter. laser plasma)

  5. Comparison of high-intensity sound and mechanical vibration for cleaning porous titanium cylinders fabricated using selective laser melting.

    Science.gov (United States)

    Seiffert, Gary; Hopkins, Carl; Sutcliffe, Chris

    2017-01-01

    Orthopedic components, such as the acetabular cup in total hip joint replacement, can be fabricated using porous metals, such as titanium, and a number of processes, such as selective laser melting. The issue of how to effectively remove loose powder from the pores (residual powder) of such components has not been addressed in the literature. In this work, we investigated the feasibility of two processes, acoustic cleaning using high-intensity sound inside acoustic horns and mechanical vibration, to remove residual titanium powder from selective laser melting-fabricated cylinders. With acoustic cleaning, the amount of residual powder removed was not influenced by either the fundamental frequency of the horn used (75 vs. 230 Hz) or, for a given horn, the number of soundings (between 1 and 20). With mechanical vibration, the amount of residual powder removed was not influenced by the application time (10 vs. 20 s). Acoustic cleaning was found to be more reliable and effective in removal of residual powder than cleaning with mechanical vibration. It is concluded that acoustic cleaning using high-intensity sound has significant potential for use in the final preparation stages of porous metal orthopedic components. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 117-123, 2017. © 2015 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc.

  6. Anti-Stokes scattering and Stokes scattering of stimulated Brillouin scattering cascade in high-intensity laser-plasmas interaction

    Science.gov (United States)

    Feng, Qingsong; Zheng, Chunyang; Liu, Zhanjun; Xiao, Chengzhuo; Wang, Qing; Cao, Lihua; He, Xiantu

    2017-10-01

    The anti-Stokes scattering and Stokes scattering in stimulated Brillouin scattering (SBS) cascade have been researched by the Vlasov-Maxwell simulation. In the high-intensity laser-plasmas interaction, the stimulated anti-Stokes Brillouin scattering (SABS) will occur after the second stage SBS rescattering. The mechanism of SABS has been put forward to explain this phenomenon. In the early time of SBS evolution, only the first stage SBS appears, and the total SBS reflectivity comes from the first stage SBS. However, when the high-stage SBS and SABS occur, the SBS reflectivity will appear a burst behavior, and the total reflectivity comes from the SBS cascade and SABS superimposition. The SABS will compete with the SBS rescattering to determine the total SBS reflectivity. Thus, the SBS rescattering including the SABS is an important saturation mechanism of SBS, and should be taken into account in the high-intensity laser-plasmas interaction. This research was supported by the National Natural Science Foundation of China (Grant Nos. 11375032, 11575035, 11475030 and 11435011), National Basic Research Program of China (Grant No. 2013CB834101) and Science Challenge Project, No. TZ2016005.

  7. Study of 2ω and 3/2ω harmonics in ultrashort high-intensity laser ...

    Indian Academy of Sciences (India)

    is produced by electron plasma wave coupling at the critical density surface of the plasma. The other mechanism of generation of 2ω is when the intense laser field drives a relativistic oscillation of plasma surface, which causes a periodic phase modulation of the reflected light and, hence, the emission of harmonics of the ...

  8. Acceleration of Charged Particles by High Intensity Few-Cycle Laser Pulses

    CERN Document Server

    Schramm, Ulrich; Geissler, Michael; Grüner, Florian; Habs, Dietrich; Karsch, Stefan; Krausz, Ferenc; Meyer-ter-Vehn, J; Schmid, K; Schreiber, J; Tsakiris, George; Veisz, Laszlo; Witte, Klaus

    2005-01-01

    Only recently a breakthrough in laser plasma acceleration has been achieved with the observation of intense (nC) mono-energetic (10% relative width) electron beams in the 100MeV energy range.* Above the wave-breaking threshold the electrons are trapped and accelerated in a single wake of the laser pulse, called bubble, according to PIC simulations.** However, pulse energis varied from shot-to-shot in the experiments. At the MPQ Garching we prepare the stable acceleration of electrons by this bubble regime by the use of 10TW few-cycle laser pulse. As the pulse lenght of 5-10fs remains below the plasma period also at higher plama densities, we expect the scheme to be more stable and efficient. The status of the experiment will be reported. Further, we exploit a colliding beam setup existing at the Jena multi TW laser system for the investigation of the positron generation in the electron-electron collision or in the collision of hard X-rays resulting from Thomson backscattering. The presentation of results on h...

  9. Surface treatment of screw shaped titanium dental implants by high intensity laser pulses

    Science.gov (United States)

    Pető, G.; Karacs, A.; Pászti, Z.; Guczi, L.; Divinyi, T.; Joób, A.

    2002-01-01

    Machined and Al 2O 3 blasted surfaces of screw shaped Ti dental implants were irradiated by 30 ns pulses of Nd:glass laser at 1064 nm wavelength with 0.5-3 J pulse energy. The laser treatment increased the temperature of the Ti surface well above the melting temperature. The resulting ablation of some surface layers was followed by a very rapid solidification. These thermal processes strongly modified the original morphology of the surface and removed the contaminations. The new morphology was characterized by features mostly in ten micron and partly in submicron ranges. The surface composition was the same as the bulk titanium without any segregation. Animal experiments demonstrated that this surface treatment seems to be promising for the improvement of the osseointegration of dental implants.

  10. Extreme Nonlinear Optics of High Intensity Laser Pulse Filamentation in Gases

    Science.gov (United States)

    2016-05-12

    progress, quarterly, research, special, group study , etc. 3. DATES COVERED. Indicate the time during which the work was performed and the report was...multimode beams after collapse, but we believe they provide a unifying principle for all self-focusing and propagation phenomena. We believe that the study ...based THz generation experiments using two- colour (400nm and 80nm) drive pulses in the atmosphere, the 2 TW 10 Hz laser in Milchberg’s lab was used

  11. Continuous dual-wavelength, high-intensive Nd:YAG laser in operative urology

    Science.gov (United States)

    Reznikov, Leonid L.; Pupkova, Ludmila S.; Miroshnicov, B. I.; Snezhko, D. A.; Nikitichev, A. A.; Pokrovskiy, Vasiliy P.; Gomberg, Vladimir G.

    1994-05-01

    A ruby laser with a 0.694 mkm wavelength was used as a source of a new model of laser lithotriptor. The optical irradiation parameters selected included 1 mks duration pulse, frequency from 1 to 5 Hz, energy at an output of up to 120 mJ, transmitted via light guide quartz fiber of 400 kmk. The tip of the light guide was directed to the calculus through a catheterized cystoscope. Light guide position control was done by the presence of a specific acoustic signal accompanying plasma formation. Plasma is not formed by laser action on the ureter wall. In doubtful cases we used roentgenological examination. After lithotripsy and direct processing by irradiation, histological investigations of the ureter wall showed only slight submucosal hemorrhage or revealed no changes. Implantation of the calculus and fiber particles into the ureter wall was not observed. Twenty-nine patients were subjected to lithotripsy of calculus (oxalates, urates, phosphates) in the low and mid-ureter. Usually from 1000 to 3000 impulses were used to destroy the calculus. Calculus fragments passed without assistance (13 patients) or were removed by extractors (7 patients). The recovery of passing of urine and removal of renal colic were observed during lithotripsy if obturation had occurred (8 patients). Ureteral perforation, blood loss, and acute pyelonephritis did not occur.

  12. Generation of shock waves in dense plasmas by high-intensity laser pulses

    Directory of Open Access Journals (Sweden)

    Pasley John

    2015-06-01

    Full Text Available When intense short-pulse laser beams (I > 1022 W/m2, τ < 20 ps interact with high density plasmas, strong shock waves are launched. These shock waves may be generated by a range of processes, and the relative significance of the various mechanisms driving the formation of these shock waves is not well understood. It is challenging to obtain experimental data on shock waves near the focus of such intense laser–plasma interactions. The hydrodynamics of such interactions is, however, of great importance to fast ignition based inertial confinement fusion schemes as it places limits upon the time available for depositing energy in the compressed fuel, and thereby directly affects the laser requirements. In this manuscript we present the results of magnetohydrodynamic simulations showing the formation of shock waves under such conditions, driven by the j × B force and the thermal pressure gradient (where j is the current density and B the magnetic field strength. The time it takes for shock waves to form is evaluated over a wide range of material and current densities. It is shown that the formation of intense relativistic electron current driven shock waves and other related hydrodynamic phenomena may be expected over time scales of relevance to intense laser–plasma experiments and the fast ignition approach to inertial confinement fusion. A newly emerging technique for studying such interactions is also discussed. This approach is based upon Doppler spectroscopy and offers promise for investigating early time shock wave hydrodynamics launched by intense laser pulses.

  13. Pair creation in collision of γ-ray beams produced with high-intensity lasers.

    Science.gov (United States)

    Ribeyre, X; d'Humières, E; Jansen, O; Jequier, S; Tikhonchuk, V T; Lobet, M

    2016-01-01

    Direct production of electron-positron pairs in two-photon collisions, the Breit-Wheeler process, is one of the basic processes in the universe. However, it has never been directly observed in the laboratory because of the absence of the intense γ-ray sources. Laser-induced synchrotron sources emission may open a way to observe this process. The feasibility of an experimental setup using a MeV photon source is studied in this paper. We compare several γ-ray sources and estimate the expected number of electron-positron pairs and competing processes by using numerical simulations including quantum electrodynamic effects.

  14. Efficacy of high intensity diode laser as an adjunct to non-surgical periodontal treatment: a randomized controlled trial.

    Science.gov (United States)

    De Micheli, Giorgio; de Andrade, Ana Karina Pinto; Alves, Vanessa Tubero Euzebio; Seto, Marcio; Pannuti, Cláudio Mendes; Cai, Silvana

    2011-01-01

    The high intensity diode laser has been studied in periodontics for the reduction of subgingival bacteria in non-surgical treatment. Our study evaluated the bacterial effect as well as changes in periodontal clinical parameters promoted by root scaling and planing associated with this wavelength. Twenty-seven patients randomly assigned in two groups underwent root scaling and planing on the tested sites, and only the experimental group received the diode laser irradiation. Among the clinical parameters studied, the clinical probing depth (CPD) and the clinical attachment level (CAL) resulted in significant enhancement in the control group when compared with the experimental group (P = 0.014 and P = 0.039, respectively). The results were similar for both groups regarding the plaque index (PI) and bleeding on probing (BP). No significant difference in the microbiological parameters was observed between the control and experimental groups. It was possible to conclude that the high power diode laser adjunct to the non-surgical periodontal treatment did not promote additional effects to the conventional periodontal treatment.

  15. Recent experiments on electron transport in high-intensity laser matter interaction

    Science.gov (United States)

    Baton, S. D.; Batani, D.; Manclossi, M.; Morace, A.; Piazza, D.; Benuzzi-Mounaix, A.; Koenig, M.; Guillou, P.; Loupias, B.; Fuchs, J.; Amiranoff, F.; Rabec LeGloahec, M.; Popescu, H.; Rousseaux, C.; Borghesi, M.; Cecchetti, C.; Kodama, R.; Norimatsu, T.; Nakatsutsumi, M.; Aglitskiy, Y.

    2005-12-01

    We present the results of some recent experiments performed at the LULI laboratory using the 100 TW laser facility concerning the study of the propagation of fast electrons in gas and solid targets. Novel diagnostics have been implemented including chirped shadowgraphy and proton radiography. Proton radiography images did show the presence of very strong fields in the gas probably produced by charge separation. In turn these imply a slowing down of the fast electron cloud as it penetrates in the gas and a strong inhibition of propagation. Indeed chirped shadowgraphy images show a strong reduction in time of the velocity of the electron cloud from the initial value, which is of the order of a fraction of c. We also performed some preliminary experiments with cone targets in order to verify the guiding effect and fast electron propagation in presence of the cone. Finally we compared results obtained by changing the target size. Here we only give a first presentation and preliminary analysis of data, which will be addressed in detail in a following paper.

  16. Extraction of high-intensity ion beams from a laser plasma by a pulsed spherical diode

    Directory of Open Access Journals (Sweden)

    Yoshiyuki Oguri

    2005-06-01

    Full Text Available High-current Cu^{+} ion beams were extracted from a laser-produced plasma using a pulsed high-voltage multiaperture diode driven by an induction cavity. The amplitude and the duration of the extraction voltage were 130 kV and 450 ns, respectively. During the extraction, explosive beam divergence due to the strong space-charge force was suppressed by the focusing action of the gap between concentric hemispheres. Modulation of the extracted beam flux due to the plasma prefill in the gap has been eliminated by using a biased control grid put on the anode holes. By means of this extraction scheme we obtained a rectangular beam pulse with a rise time as short as ≈100  ns. The beam current behind the cathode was limited to ≈0.1   A, owing to space-charge effects, as well as to poor geometrical transmission through the cathode sphere. From the measurement of the extracted beam current density distribution along the beam axis and the beam profile measurement, we found a beam waist slightly downstream of the spherical center of the diode structure. The measured beam behavior was consistent with numerical results obtained via a 3D particle code. No serious degradation of the beam emittance was observed for the grid-controlled extraction scheme.

  17. Stochastic behavior of electrons in high intensity laser-plasma interaction

    Science.gov (United States)

    Khalilzadeh, Elnaz; Chakhmachi, Amir; Yazdanpanah, Jamalaldin

    2017-12-01

    The stochastic behavior of electrons during the interaction of an intense short laser pulse with under-dense plasma is investigated by employing a fully kinetic 1D-3V particle-in-cell (PIC) simulation. The development of chaos in the involved nonlinear regime and in the presence of plasma space charge is examined. Though the electron Lagrangian is extremely complicated in this case, our analyses suggest some potential ways for chaos development. In this regard, our simulation results show that chaotic motion can develop in three different ways. When the space charge field is weak, the scattered fields can provide the necessary condition for chaos to occur. When a strong space charge field is presented, the creation of chaos is initiated by wave breaking. The third procedure for creating chaos originates from the inhomogeneity of the density on the vacuum-plasma surface. In this case, a new electrostatic mode without any phase relation with the space charge electrostatic mode is generated.

  18. Laser plasma instabilities and hot electron generation from multi-kilojoule shock ignition relevant high-intensity IR and UV lasers

    Science.gov (United States)

    Zhang, S.; Li, J.; Beg, F. N.; Krauland, C. M.; Muller, S.; Alexander, N.; Ren, C.; Theobald, W.; Turnbull, D.; Haberberger, D.; Betti, R.; Campbell, E. M.; Batani, D.; Santos, J.; Nicolai, P.; Wei, M. S.

    2017-10-01

    As an alternative ignition scheme, shock ignition uses a strong convergent shock driven by a high-intensity laser ( 1016 W/cm2) on a pre-compressed fuel to achieve ignition. Moderately energetic hot electrons (laser plasma instabilities (LPI) can strengthen the ignition shock by depositing energy at the compressed outer shell increasing ablation pressure. In our previous experiments on OMEGA-EP, 90 keV collimated hot electrons were observed from a 100 ps, 2.5 kJ IR laser interacting with SI long scale length hot plasmas (Ln 200 -500 µm, Te >1 keV, produced by low-intensity UV beams). To further characterize hot electron generation and investigate the related LPIs, we have extended the experiments with high-intensity, multi-kJ IR and UV lasers (both at normal incidence, up to 2×1016 W/cm2) . Two IR beams in co-propagation extend the pulse duration to 200 ps, closer to required ignition pulse duration. The scattered light is spectrally resolved to identify the LPI. Angular filter refractometer images from 4 ω probe show the details of the laser propagation and interaction. The divergence, energy, and temperature of the hot electrons are diagnosed by measuring the bremsstrahlung and Cu K α emission. Details of the experimental results will be presented. This work is supported by the U. S. DOE under contracts DE-NA0003600 (NLUF) and DE-SC0014666 (HEDLP).

  19. Producing High Intense Attosecond Pulse Train by Interaction of Three-Color Pulse and Overdense Plasma

    Science.gov (United States)

    Salehi, M.; Mirzanejad, S.

    2017-05-01

    Amplifying the attosecond pulse by the chirp pulse amplification method is impossible. Furthermore, the intensity of attosecond pulse is low in the interaction of laser pulse and underdense plasma. This motivates us to propose using a multi-color pulse to produce the high intense attosecond pulse. In the present study, the relativistic interaction of a three-color linearly-polarized laser-pulse with highly overdense plasma is studied. We show that the combination of {{ω }}1, {{ω }}2 and {{ω }}3 frequencies decreases the instance full width at half maximum reflected attosecond pulse train from the overdense plasma surface. Moreover, we show that the three-color pulse increases the intensity of generated harmonics, which is explained by the relativistic oscillating mirror model. The obtained results demonstrate that if the three-color laser pulse interacts with overdense plasma, it will enhance two orders of magnitude of intensity of ultra short attosecond pulses in comparison with monochromatic pulse.

  20. Effects of radiation reaction in the interaction between cluster media and high intensity lasers in the radiation dominant regime

    Science.gov (United States)

    Iwata, Natsumi; Nagatomo, Hideo; Fukuda, Yuji; Matsui, Ryutaro; Kishimoto, Yasuaki

    2016-06-01

    Interaction between media composed of clusters and high intensity lasers in the radiation dominant regime, i.e., intensity of 10 22 - 23 W / cm 2 , is studied based on the particle-in-cell simulation that includes the radiation reaction. By introducing target materials that have the same total mass but different internal structures, i.e., uniform plasma and cluster media with different cluster radii, we investigate the effect of the internal structure on the interaction dynamics, high energy radiation emission, and its reaction. Intense radiation emission is found in the cluster media where electrons exhibit non-ballistic motions suffering from strong accelerations by both the penetrated laser field and charge separation field of clusters. As a result, the clustered structure increases the energy conversion into high energy radiations significantly at the expense of the conversion into particles, while the total absorption rate into radiation and particles remains unchanged from the absorption rate into particles in the case without radiation reaction. The maximum ion energy achieved in the interaction with cluster media is found to be decreased through the radiation reaction to electrons into the same level with that achieved in the interaction with the uniform plasma. The clustered structure thus enhances high energy radiation emission rather than the ion acceleration in the considered intensity regime.

  1. High-intensity UV laser ChIP-seq for the study of protein-DNA interactions in living cells.

    Science.gov (United States)

    Steube, Arndt; Schenk, Tino; Tretyakov, Alexander; Saluz, Hans Peter

    2017-11-03

    Genome-wide mapping of transcription factor binding is generally performed by chemical protein-DNA crosslinking, followed by chromatin immunoprecipitation and deep sequencing (ChIP-seq). Here we present the ChIP-seq technique based on photochemical crosslinking of protein-DNA interactions by high-intensity ultraviolet (UV) laser irradiation in living mammalian cells (UV-ChIP-seq). UV laser irradiation induces an efficient and instant formation of covalent "zero-length" crosslinks exclusively between nucleic acids and proteins that are in immediate contact, thus resulting in a "snapshot" of direct protein-DNA interactions in their natural environment. Here we show that UV-ChIP-seq, applied for genome-wide profiling of the sequence-specific transcriptional repressor B-cell lymphoma 6 (BCL6) in human diffuse large B-cell lymphoma (DLBCL) cells, produces sensitive and precise protein-DNA binding profiles, highly enriched with canonical BCL6 DNA sequence motifs. Using this technique, we also found numerous previously undetectable direct BCL6 binding sites, particularly in condensed, inaccessible areas of chromatin.

  2. Generation of ultra-intense and ultra-short laser pulses with high temporal contrast; Generation d'impulsions laser ultra-breves et ultra-intenses a contraste temporel eleve

    Energy Technology Data Exchange (ETDEWEB)

    Julien, A

    2006-03-15

    The topic of this thesis work concerns the design and the characterization of an efficient device devoted to the temporal contrast improvement for ultra-intense femtosecond laser pulses. The contrast is defined as the intensity ratio between the main femtosecond pulse and its nanosecond pedestal. This pedestal is the amplified spontaneous emission (ASE), inherent with laser amplification mechanism. The ASE background has dramatic effects for laser-matter interactions on a solid target. The presented work consists in the theoretical and experimental study of a temporal filter based on a third order nonlinear effect acting on the pulse polarization. We have studied several kinds of nonlinear filters. The selected device is based on the process of cross-polarized wave generation (XPW) in crystals with an anisotropic third-order nonlinear susceptibility. This nonlinear filter has been experimented on various femtosecond systems. It allows a contrast improvement of several orders of magnitude, as demonstrated by temporal profiles measurements on a large intensity dynamic. A device to improve the nonlinear process conversion efficiency, it means the filter transmission, has also been achieved. This method is based on constructive interferences between XPW signals generated in different crystals. This setup has made it possible to reach experimentally the maximum theoretical efficiency ( >20%) and in the same time ensures the system stability. At least, we have demonstrated that the filter preserves, or even improves, spectral and spatial qualities of the laser pulse. These results are thus particularly promising and allow contemplating the implementation of the filter in current femtosecond systems. (author)

  3. Treatment of drug-resistant fibromyalgia symptoms using high-intensity laser therapy: a case-based review.

    Science.gov (United States)

    White, Paul F; Zafereo, Jason; Elvir-Lazo, Ofelia Loani; Hernandez, Hector

    2017-10-28

    Fibromyalgia is a chronic musculoskeletal condition characterized by widespread pain in the body and is associated with tender points at the shoulder, back and hip regions. A wide variety of pharmacologic drugs and dietary supplements have been used with limited success in treating the musculoskeletal pain. Early clinical studies with low level laser therapy (LLLT) alone or in combination with drugs commonly used to treat fibromyalgia suggested that LLLT may be effective in reducing musculoskeletal pain and stiffness, as well as the number of tender locations. However, a sham-controlled study reported that LLLT was not significantly better than the sham treatment and kinesiotape. Preliminary studies with high-intensity laser therapy (HILT) suggest that it may be more effective than LLLT for treating chronic pain syndromes. Therefore, we evaluated low (1 W), intermediate (42 W) and high level (75 W) HILT in a woman with long-standing fibromyalgia syndrome which was resistant to both standard pharmacotherapy and treatment in an interdisciplinary pain management program. The patient received a series of treatments with a HILT device (Phoenix Thera-lase) at a wavelength of 1275 nm administered at both the paraspinous region and tender points in the shoulder and hip regions. Although the 1 W treatment produced minimal symptom relief, both the 42 and the 75 W treatments produced a dramatic reduction in her overall pain, improved quality of sleep, and increased her level of physical activity for 4-10 days after these treatment sessions. This case illustrates the potential beneficial effects of using higher power levels of HILT for patients with fibromyalgia syndrome who have failed to respond to conventional interdisciplinary treatment regimens.

  4. Short-term effects of high-intensity laser therapy on frozen shoulder: A prospective randomized control study.

    Science.gov (United States)

    Kim, Sae Hoon; Kim, Yeon Ho; Lee, Hwa-Ryeong; Choi, Young Eun

    2015-12-01

    Frozen shoulder, which is characterized by shoulder pain and limitation of the range of motion (ROM), is a common disorder. High-intensity laser therapy (HILT) was recently introduced in the musculoskeletal therapeutic field. The objective of this study is to evaluate the clinical efficacy of HILT in patients with frozen shoulder. A prospective randomized controlled study. Patients with frozen shoulder were randomly divided into 2 groups: a HILT group (n = 33) and a placebo group (n = 33). The treatment was administered 3 times per week on alternate days for 3 weeks. For all patients, the visual analog scale (VAS) for pain, VAS for satisfaction, and passive ROM were measured at baseline and 3, 8, and 12 weeks after the treatment. The HILT group had a lower pain VAS score at 3 weeks (3.2 ± 1.7 vs. 4.3 ± 2.2, p = 0.033) and 8 weeks (2.2 ± 2.0 vs. 3.4 ± 2.7, p = 0.042), however, no statistically significant difference in the pain VAS was observed between the two groups at the final follow-up (12 weeks). No statistical difference in the ROM and the satisfaction VAS was observed between the 2 groups at serial follow-ups. In management of frozen shoulder, HILT provided significant pain relief at 3 and 8 weeks, but not at the final follow-up time point. HILT is a noninvasive adjuvant treatment that can reduce pain in frozen shoulders. Further study is needed in order to optimize the dose and duration of HILT. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Compton scattering at high intensities

    Energy Technology Data Exchange (ETDEWEB)

    Heinzl, Thomas, E-mail: thomas.heinzl@plymouth.ac.u [University of Plymouth, School of Mathematics and Statistics, Drake Circus, Plymouth PL4 8AA (United Kingdom)

    2009-12-01

    High-intensity Compton scattering takes place when an electron beam is brought into collision with a high power laser. We briefly review the main intensity signatures using the formalism of strong-field quantum electrodynamics.

  6. Perturbative effects on ultra-short soliton self-switching

    Indian Academy of Sciences (India)

    A numerical study of ultra-short self-soliton switching along with the corresponding analysis of coupler parameters is carried out for a Kerr coupler with intermodal dispersion. The influence of perturbations like third-order dispersion, self-steepening and intrapulse Raman scattering, on switching characteristics is also studied ...

  7. Long-term effect of pulsed high-intensity laser therapy in the treatment of post-mastectomy pain syndrome: a double blind, placebo-control, randomized study.

    Science.gov (United States)

    Ebid, Anwar Abdelgayed; El-Sodany, Ahmed Mohamed

    2015-08-01

    We assess the long-term effect of pulsed high-intensity laser therapy (HILT) in the treatment of the post-mastectomy pain syndrome (PMPS). A total of 61 women participated in this study (30 in the laser group and 31 in the placebo laser group), with a mean age of 53.56 ± 1.11 years. Patients who were randomly assigned to the laser group received HILT three times per week for 4 weeks, plus a routine physical therapy program (RPTP). The placebo laser group received placebo HILT plus RPTP. The outcomes measured were pain level by visual analog scale (VAS), shoulder range of motion (ROM), and quality of life (QOL). Statistical analysis was performed by ANOVA with repeated measures to compare the differences between baseline and post-treatment measurements and after 12 weeks of follow-up for both groups. The level of statistical significance was set at P placebo group. VAS results showed a significant decrease post-treatment in the laser group relative to the placebo group, and QOL results showed a significant improvement in the laser group compared with the placebo group and still improved after 12 weeks of follow-up. HILT combined with an RPTP appears to be more effective in patients with PMPS than a placebo laser procedure with RPTP.

  8. Prostate vaporization in the treatment of benign prostatic hyperplasia by using a 200-w high-intensity diode laser.

    Science.gov (United States)

    Chiang, Po-Hui; Chen, Chien-Hsu

    2010-07-01

    The recent introduction of high-power 200-W diode laser vaporization of the prostate has resulted in new interest in minimally invasive surgery for the treatment of benign prostatic hyperplasia (BPH). Although clinical reports are still limited, experimental ex vivo or in vivo models have demonstrated that this laser device offers improved ablative and hemostatic abilities. Some preliminary clinical results have proven that this laser technique can efficiently improve the symptoms of BPH. However, this still requires long-term evidence to support the use of this laser device. In this article, we review the latest experience with this laser technique and compare other laser systems in the treatment of BPH in recent years.

  9. A numerical study of ultra-short-pulse reflectometry

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, B.I.; Afeyan, B.B. [Lawrence Livermore National Lab., CA (United States); Chou, A.E. [Univ. of California, Los Angeles, CA (United States). Dept. of Electrical Engineering]|[California Univ., Davis, CA (United States). Dept. of Applied Science; Luhmann, N.C. Jr. [California Univ., Davis, CA (United States). Dept. of Applied Science

    1994-05-01

    Ultra-short-pulse reflectometry is studied by means of the numerical integration of a one-dimensional full-wave equation for ordinary modes propagating in a plasma. The numerical calculations illustrate the potential of using the reflection of ultra-short-pulse, microwaves as an effective probe of the density profile even in the presence of significant density fluctuations. The difference in time delays of differing frequency components of the microwaves can be used to deduce the density profile. The modification of the reflected pulses in the presence of density fluctuations is examined and can be understood based on considerations of Bragg resonance. A simple and effective profile-reconstruction algorithm using the zero-crossings of the reflected pulse and subsequent Abel inversion is demonstrated. The robustness of the profile reconstruction algorithm in the presence of a sufficiently small amplitude density perturbation is assessed.

  10. Optical soliton communication using ultra-short pulses

    CERN Document Server

    Sadegh Amiri, Iraj

    2015-01-01

    This brief analyzes the characteristics of a microring resonator (MRR) to perform communication using ultra-short soliton pulses. The raising of nonlinear refractive indices, coupling coefficients and radius of the single microring resonator leads to decrease in input power and round trips wherein the bifurcation occurs. As a result, bifurcation or chaos behaviors are seen at lower input power of 44 W, where the nonlinear refractive index is n2=3.2×10−20 m2/W. Using a decimal convertor system, these ultra-short signals can be converted into quantum information. Results show that multi solitons with FWHM and FSR of 10 pm and 600 pm can be generated respectively. The multi optical soliton with FWHM and FSR of 325 pm and 880 nm can be incorporated with a time division multiple access (TDMA) system wherein the transportation of quantum information is performed.

  11. Ablation Behavior of Plasma-Sprayed La1-xSrxTiO3+δ Coating Irradiated by High-Intensity Continuous Laser.

    Science.gov (United States)

    Zhu, Jinpeng; Ma, Zhuang; Gao, Yinjun; Gao, Lihong; Pervak, Vladimir; Wang, Lijun; Wei, Chenghua; Wang, Fuchi

    2017-10-11

    Laser protection for optical components, particularly those in high-power laser systems, has been a major concern. La1-xSrxTiO3+δ with its good optical and thermal properties can be potentially applied as a high-temperature optical protective coating or high-reflectivity material for optical components. However, the high-power laser ablation behavior of plasma-sprayed La1-xSrxTiO3+δ (x = 0.1) coatings has rarely been investigated. Thus, in this study, laser irradiation experiments were performed to study the effect of high-intensity continuous laser on the ablation behavior of the La1-xSrxTiO3+δ coating. The results show that the La1-xSrxTiO3+δ coating undergoes three ablation stages during laser irradiation: coating oxidation, formation and growth of new structures (columnar and dendritic crystals), and mechanical failure. A finite-element simulation was also conducted to explore the mechanism of the ablation damage to the La1-xSrxTiO3+δ coating and provided a good understanding of the ablation behavior. The apparent ablation characteristics are attributed to the different temperature gradients determined by the reflectivity and thermal diffusivity of the La1-xSrxTiO3+δ coating material, which are critical factors for improving the antilaser ablation property. Now, the stainless steel substrate deposited by it can effectively work as a protective shield layer against ablation by laser irradiation.

  12. Ultra-short Period Binaries from the Catalina Surveys

    Science.gov (United States)

    Drake, A. J.; Djorgovski, S. G.; García-Álvarez, D.; Graham, M. J.; Catelan, M.; Mahabal, A. A.; Donalek, C.; Prieto, J. L.; Torrealba, G.; Abraham, S.; Williams, R.; Larson, S.; Christensen, E.

    2014-08-01

    We investigate the properties of 367 ultra-short period binary candidates selected from 31,000 sources recently identified from Catalina Surveys data. Based on light curve morphology, along with WISE, Sloan Digital Sky Survey, and GALEX multi-color photometry, we identify two distinct groups of binaries with periods below the 0.22 day contact binary minimum. In contrast to most recent work, we spectroscopically confirm the existence of M dwarf+M dwarf contact binary systems. By measuring the radial velocity variations for five of the shortest-period systems, we find examples of rare cool white dwarf (WD)+M dwarf binaries. Only a few such systems are currently known. Unlike warmer WD systems, their UV flux and optical colors and spectra are dominated by the M-dwarf companion. We contrast our discoveries with previous photometrically selected ultra-short period contact binary candidates and highlight the ongoing need for confirmation using spectra and associated radial velocity measurements. Overall, our analysis increases the number of ultra-short period contact binary candidates by more than an order of magnitude.

  13. Ablation of burned skin with ultra-short pulses laser to promote healing: evaluation by optical coherence tomography, histology, {mu}ATR-FTIR and Nonlinear Microscopy; Ablacao de pele queimada com laser de pulsos ultra-curtos para promocao da cicatrizacao: avaliacao por tomografia por coerencia optica, histologia, {mu}ATR-FTIR e microscopia nao-linear

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Moises Oliveira dos

    2012-07-01

    Burns cause changes in the anatomical structure of the skin associated with trauma. The severity of the burn injury is divided into first, second and third-degree burns. The third-degree burns have been a major focus of research in search of more conservative treatments and faster results in repair for a functional and cosmetically acceptable. The conventional treatment is the use of topical natural or synthetic skin graft. An alternative therapy is the laser ablation process for burned tissue necrosis removal due to the no mechanical contact, fast application and access to difficult areas. The purpose of this study is to evaluate the feasibility of using high intensity femtosecond lasers as an adjunct treatment of burned patients. For this study, 65 Wistar rats were divided into groups of five animals: healthy skin, burned skin, two types of treatment (surgical debridement or femtosecond laser ablation) and four different times in the healing process monitoring. Three regions of the back of the animals were exposed to steam source causing third-degree burn. On the third day after the burn, one of the regions was ablated with high intensity ultrashort laser pulses ({lambda} = 785 nm, 90 fs, 2 kHz and 10 {mu}J/ pulse), the other received surgical debridement, and the last was considered the burn control. The regions were analyzed by optical coherence tomography (OCT), histology, attenuated total reflectance infrared spectroscopy using Fourier transform ({mu}-ATR-FTIR), two-photon excitation fluorescence microscopy (TPEFM) and second harmonic generation technique (SHG) on days 3, 5, 7 and 14 pos-treatments. The results showed that with the laser irradiation conditions used it was possible to remove debris from third degree burn. The techniques used to characterize the tissue allowed to verify that all treatments promoted wound healing. On the fourteenth day, the regeneration curve showed that the attenuation coefficient of laser ablated tissue converges to the values

  14. Comparative evaluation of the effects of high-intensity and low-intensity laser radiation on microcirculation among patients with knee arthritis

    Science.gov (United States)

    Kulchitskaya, D. B.; Konchugova, T. V.; E Fedorova, N.

    2017-04-01

    Sixty patients with knee arthritis aged from 40 to 75 years old were examined. The patients were randomly divided into two groups: 1st group (30 patients) received high intensity laser radiation; 2nd group (20 patients) received low intensity laser radiation. As a result of the conducted research it was found that high intensity laser radiation is more efficient and leads to more vivid positive changes in the microcirculation of patients with knee arthritis. The changes in microcirculation were based on the normalization of the myogenic and neurogenic tonus of the arterioles, strengthening oscillation of the endothelial range. As a result of local mechanisms activation of tissue blood flow there occurs adequate modulation of the microcirculatory bloodstream, which is aimed at the elimination of congestive phenomena in the capillary and venular level of the microcirculation bloodstream. We should note that in the long-term more significant were the positive changes in the state of the venular level of the microcirculation bloodstream. in constructing both.

  15. ARTICLES: Heating of heat-conducting targets by laser pulses with a high-intensity leading spike

    Science.gov (United States)

    Ageev, Vladimir P.; Burdin, S. G.; Konov, Vitalii I.; Uglov, S. A.; Chapliev, N. I.

    1983-04-01

    The results of an analysis of the solution of a one-dimensional heat conduction equation are used to study the specific features of the thermal effects of laser pulses with a leading spike on a target. Simple criteria are obtained for establishing the ability of a pulse to cause a given increase in the target surface temperature during the leading edge of a spike and also during the tail of the laser pulse. A study is made of the influence of the inhomogeneity of the distribution of surface heat sources on the realization of processes characterized by a threshold in respect of the temperature of the irradiated surface. The results obtained are compared with the experimental delay time in the process of initiation of an air breakdown plasma by interaction of CO2 laser pulses with a metal target.

  16. Method of synchronization measurement via spatial-spectral interference in coherent combination of multi-channel ultra-short pulses

    Science.gov (United States)

    Li, Z. L.; Zuo, Y. L.; Wu, Z. H.; Wang, X.; Mu, J.; Yu, H. Y.; Zhao, D.; Zhu, Q. H.; Su, J. Q.; Zhou, K. N.; Zhou, S.; Feng, X.; Zhang, S.; Liu, H. Z.

    2017-08-01

    Spatial-spectral interference fringes contain information on the time delay between pulses. By extracting the slope of the equiphase line in the spatial-spectral interference fringes, a large range and high-precision detection of the time delay is realized. Theoretical analysis is given. An experiment demonstrates the fundamental process for obtaining the time delay between two femtosecond pulses. In the current experiment the measurement range is from 0.4 fs to hundreds of fs. This method was first proposed for synchronization measurement of coherent combination of ultra-short pulses in a multi-channel system. The method can be applied at large scales in an ultra-short pulse laser facility.

  17. Temperature changes on the root surfaces of mandibular incisors after an 810-nm high-intensity intracanal diode laser irradiation

    Science.gov (United States)

    da Fonseca Alvarez, Andrea; Moura-Netto, Cacio; Daliberto Frugoli, Alexandre; Fernando, Casemiro; Correa Aranha, Ana Cecilia; Davidowicz, Harry

    2012-01-01

    Temperature changes caused by laser irradiation can promote damage to the surrounding dental tissues. In this study, we evaluated the temperature changes of recently extracted human mandibular incisors during intracanal irradiation with an 810-nm diode laser at different settings. Fifty mandibular incisors were enlarged up to an apical size of ISO No. 40 file. After the final rinse with 17% ethylenediaminetetraacetic acid, 0.2% lauryl sodium sulfate biologic detergent, and sterile water, samples were irradiated with circular movements from apex to crown through five different settings of output power (1.5, 2.0, 2.5, 3.0, and 3.5 W) in continuous mode. The temperature changes were measured on both sides of the apical and middle root thirds using two thermopar devices. A temperature increase of 7 °C was considered acceptable as a safe threshold when applying the diode laser. Results: The results showed that only 3.5-W output power increased the outer surface temperature above the critical value. Conclusion: The recommended output power can be stipulated as equal to or less than 3 W to avoid overheating during diode laser irradiation on thin dentin walls.

  18. Ultra-short strong excitation of two-level systems

    Science.gov (United States)

    Jha, Pankaj K.; Eleuch, Hichem; Grazioso, Fabio

    2014-11-01

    We present a model describing the use of ultra-short strong pulses to control the population of the excited level of a two-level quantum system. In particular, we study an off-resonance excitation with a few cycles pulse which presents a smooth phase jump i.e. a change of the pulse's phase which is not step-like, but happens over a finite time interval. A numerical solution is given for the time-dependent probability amplitude of the excited level. The control of the excited level's population is obtained acting on the shape of the phase transient, and other parameters of the excitation pulse.

  19. Commissioning of a compact laser-based proton beam line for high intensity bunches around 10 MeV

    Directory of Open Access Journals (Sweden)

    S. Busold

    2014-03-01

    Full Text Available We report on the first results of experiments with a new laser-based proton beam line at the GSI accelerator facility in Darmstadt. It delivers high current bunches at proton energies around 9.6 MeV, containing more than 10^{9} particles in less than 10 ns and with tunable energy spread down to 2.7% (ΔE/E_{0} at FWHM. A target normal sheath acceleration stage serves as a proton source and a pulsed solenoid provides for beam collimation and energy selection. Finally a synchronous radio frequency (rf field is applied via a rf cavity for energy compression at a synchronous phase of -90  deg. The proton bunch is characterized at the end of the very compact beam line, only 3 m behind the laser matter interaction point, which defines the particle source.

  20. Nonlinear threshold effect in the Z-scan method of characterizing limiters for high-intensity laser light

    Energy Technology Data Exchange (ETDEWEB)

    Tereshchenko, S. A., E-mail: tsa@miee.ru; Savelyev, M. S.; Podgaetsky, V. M.; Gerasimenko, A. Yu.; Selishchev, S. V. [National Research University of Electronic Technology, Moscow (Russian Federation)

    2016-09-07

    A threshold model is described which permits one to determine the properties of limiters for high-powered laser light. It takes into account the threshold characteristics of the nonlinear optical interaction between the laser beam and the limiter working material. The traditional non-threshold model is a particular case of the threshold model when the limiting threshold is zero. The nonlinear characteristics of carbon nanotubes in liquid and solid media are obtained from experimental Z-scan data. Specifically, the nonlinear threshold effect was observed for aqueous dispersions of nanotubes, but not for nanotubes in solid polymethylmethacrylate. The threshold model fits the experimental Z-scan data better than the non-threshold model. Output characteristics were obtained that integrally describe the nonlinear properties of the optical limiters.

  1. Generation of High-Power High-Intensity Short X-Ray Free-Electron-Laser Pulses.

    Science.gov (United States)

    Guetg, Marc W; Lutman, Alberto A; Ding, Yuantao; Maxwell, Timothy J; Decker, Franz-Josef; Bergmann, Uwe; Huang, Zhirong

    2018-01-05

    X-ray free-electron lasers combine a high pulse power, short pulse length, narrow bandwidth, and high degree of transverse coherence. Any increase in the photon pulse power, while shortening the pulse length, will further push the frontier on several key x-ray free-electron laser applications including single-molecule imaging and novel nonlinear x-ray methods. This Letter shows experimental results at the Linac Coherent Light Source raising its maximum power to more than 300% of the current limit while reducing the photon pulse length to 10 fs. This was achieved by minimizing residual transverse-longitudinal centroid beam offsets and beam yaw and by correcting the dispersion when operating over 6 kA peak current with a longitudinally shaped beam.

  2. Ta-ion implantation induced by a high-intensity laser for plasma diagnostics and target preparation

    Science.gov (United States)

    Cutroneo, M.; Malinsky, P.; Mackova, A.; Matousek, J.; Torrisi, L.; Slepicka, P.; Ullschmied, J.

    2015-12-01

    The present work is focused on the implantation of Ta ions into silicon substrates covered by a silicon dioxide layer 50-300 nm thick. The implantation is achieved using sub-nanosecond pulsed laser ablation (1015 W/cm2) with the objective of accelerating non-equilibrium plasma ions. The accelerated Ta ions are implanted into the exposed silicon substrates at energies of approximately 20 keV per charge state. By changing a few variables in the laser pulse, it is possible to control the kinetic energy, the yield and the angular distribution of the emitted ions. Rutherford Back-Scattering analysis was performed using 2.0 MeV He+ as the probe ions to determine the elemental depth profiles and the chemical composition of the laser-implanted substrates. The depth distributions of the implanted Ta ions were compared to SRIM 2012 simulations. The evaluated results of energy distribution were compared with online techniques, such as Ion Collectors (IC) and an Ion Energy Analyser (IEA), for a detailed identification of the produced ion species and their energy-to-charge ratios (M/z). Moreover, XPS (X-ray Photon Spectroscopy) and AFM (Atomic Force Microscopy) analyses were carried out to obtain information on the surface morphology and the chemical composition of the modified implanted layers, as these features are important for further application of such structures.

  3. Ta-ion implantation induced by a high-intensity laser for plasma diagnostics and target preparation

    Energy Technology Data Exchange (ETDEWEB)

    Cutroneo, M., E-mail: cutroneo@ujf.cas.cz [Nuclear Physics Institute, ASCR, 250 68 Rez (Czech Republic); Malinsky, P.; Mackova, A. [Nuclear Physics Institute, ASCR, 250 68 Rez (Czech Republic); Department of Physics, Faculty of Science, J.E. Purkinje University, Ceske mladeze 8, 400 96 Usti nad Labem (Czech Republic); Matousek, J. [Department of Physics, Faculty of Science, J.E. Purkinje University, Ceske mladeze 8, 400 96 Usti nad Labem (Czech Republic); Torrisi, L. [Department of Physics and Earth Science, Messina University, V.le F.S. d’Alcontres 31, 981 66 S. Agata, Messina (Italy); Slepicka, P. [Department of Solid State Engineering, Institute of Chemical Technology, 166 28 Prague (Czech Republic); Ullschmied, J. [Institute of Physics, ASCR, v.v.i., 182 21 Prague 8 (Czech Republic)

    2015-12-15

    The present work is focused on the implantation of Ta ions into silicon substrates covered by a silicon dioxide layer 50–300 nm thick. The implantation is achieved using sub-nanosecond pulsed laser ablation (10{sup 15} W/cm{sup 2}) with the objective of accelerating non-equilibrium plasma ions. The accelerated Ta ions are implanted into the exposed silicon substrates at energies of approximately 20 keV per charge state. By changing a few variables in the laser pulse, it is possible to control the kinetic energy, the yield and the angular distribution of the emitted ions. Rutherford Back-Scattering analysis was performed using 2.0 MeV He{sup +} as the probe ions to determine the elemental depth profiles and the chemical composition of the laser-implanted substrates. The depth distributions of the implanted Ta ions were compared to SRIM 2012 simulations. The evaluated results of energy distribution were compared with online techniques, such as Ion Collectors (IC) and an Ion Energy Analyser (IEA), for a detailed identification of the produced ion species and their energy-to-charge ratios (M/z). Moreover, XPS (X-ray Photon Spectroscopy) and AFM (Atomic Force Microscopy) analyses were carried out to obtain information on the surface morphology and the chemical composition of the modified implanted layers, as these features are important for further application of such structures.

  4. Measurement of Ultra-Short Solitary Electromagnetic Pulses

    Directory of Open Access Journals (Sweden)

    Eva Gescheidtova

    2004-01-01

    Full Text Available In connection with the events of the last few years and with the increased number of terrorist activities, the problem of identification and measurement of electromagnetic weapons or other systems impact occurred. Among these are also microwave sources, which can reach extensive peak power of up to Pmax = 100 MW. Solitary, in some cases several times repeated, impulses lasting from tp E <1, 60>ns, cause the destruction of semiconductor junctions. These days we can find scarcely no human activity, where semiconductor structures are not used. The problem of security support of the air traffic, transportation, computer nets, banks, national strategic data canter’s, and other applications crops up. Several types of system protection from the ultra-short electromagnetic pulses present itself, passive and active protection. The analysis of the possible measuring methods, convenient for the identification and measurement of the ultra-short solitary electromagnetic pulses in presented in this paper; some of the methods were chosen and used for practical measurement. This work is part of Research object MSM262200022 "Research of microelectronic systems".

  5. Recent Developments in UV Optics for Ultra-Short, Ultra-Intense Coherent Light Sources

    Directory of Open Access Journals (Sweden)

    Daniele Cocco

    2015-01-01

    Full Text Available With the advent of Free Electron Lasers and general UV ultra-short, ultra-intense sources, optics needed to transport such radiation have evolved significantly to standard UV optics. Problems like surface damage, wavefront preservation, beam splitting, beam shaping, beam elongation (temporal stretching pose new challenges for the design of beam transport systems. These problems lead to a new way to specify optics, a new way to use diffraction gratings, a search for new optical coatings, to tighter and tighter polishing requirements for mirrors, and to an increased use of adaptive optics. All these topics will be described in this review article, to show how optics could really be the limiting factor for future development of these new light sources.

  6. Ultra-short electron beams based spatio-temporal radiation biology and radiotherapy.

    Science.gov (United States)

    Malka, Victor; Faure, Jérôme; Gauduel, Yann A

    2010-01-01

    Deeply understanding the basic mechanisms of radiation damage in vitro and on living cells, starting from the early radical and molecular processes to mutagenic DNA lesions, cell signalling, genomic instability, apoptosis, microenvironment and Bystander effects, radio sensitivity should have many practical consequences such as the customization of cancer radiotherapy or radioprotection protocols. In this context, innovative laser-plasma accelerators provide ultra-short particle beams (electrons, protons) with parameters of interest for radiation biology and medical physics. This review article approaches some complex links that exist between radiation physics of new pulsed irradiation sources and potential biomedical applications. These links concern mainly the understanding of spatio-temporal events triggered by a radiation, within a fluctuating lapse of time from the initial energy deposition to primary damages of biological interest. 2010 Elsevier B.V. All rights reserved.

  7. MR thermometry analysis program for laser- or high-intensity focused ultrasound (HIFU)-induced heating at a clinical MR scanner

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Ju; Jeong, Ki Young; Oh, Seung Jae; Park, Eun Hae; Lee, Young Han; Suh, Jin Suck [Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Dae Hong [National Cancer Center, Goyang (Korea, Republic of)

    2014-12-15

    Magnetic resonance (MR) thermometry is a noninvasive method for monitoring local temperature change during thermal therapy. In this study, a MR temperature analysis program was established for a laser with gold nanorods (GNRs) and high-intensity focused ultrasound (HIFU)-induced heating MR thermometry. The MR temperature map was reconstructed using the water proton resonance frequency (PRF) method. The temperature-sensitive phase difference was acquired by using complex number subtraction instead of direct phase subtraction in order to avoid another phase unwrapping process. A temperature map-analyzing program was developed and implemented in IDL (Interactive Data Language) for effective temperature monitoring. This one program was applied to two different heating devices at a clinical MR scanner. All images were acquired with the fast spoiled gradient echo (fSPGR) pulse sequence on a 3.0 T GE Discovery MR750 scanner with an 8-channel knee array coil or with a home-built small surface coil. The analyzed temperature values were confirmed by using values simultaneously measured with an optical temperature probe (R{sup 2} = 0.996). The temperature change in small samples induced by a laser or by HIFU was analyzed by using a raw data, that consisted of complex numbers. This study shows that our MR thermometry analysis program can be used for thermal therapy study with a laser or HIFU at a clinical MR scanner. It can also be applied to temperature monitoring for any other thermal therapy based on the PRF method.

  8. Long-term effects of pulsed high-intensity laser therapy in the treatment of post-burn pruritus: a double-blind, placebo-controlled, randomized study.

    Science.gov (United States)

    Ebid, Anwar Abdelgayed; Ibrahim, Abeer Ramadan; Omar, Mohammed Taher; El Baky, Amal Mohamed Abd

    2017-04-01

    We assessed the long-term effects of pulsed high-intensity laser therapy (HILT) in post-burn pruritus treatment. A total of 49 adult burn patients with mean age of 31.53 ± 10.14 years participated, with 24 patients randomly assigned to the active laser group (ALG) and 25 in the placebo laser group (PLG). The ALG received HILT three times per week for 6 weeks, while the PLG received placebo HILT. Both groups received 10-mg cetirizine tablets twice daily and 10 mg at bedtime. All patients were advised to massage their burn scars with coconut oil for 5 min four times daily. The outcomes measured were the itch severity scale (ISS), impairment of pruritus-related quality of life (QoL), pain level by the visual analog scale (VAS), hand grip strength by handheld dynamometer, and daily cetirizine intake. Repeated-measures ANOVA was used to compare the baseline and post-treatment measurements and after 12 weeks of follow-up. Statistical significance was set at P < 0.05. ISS decreased significantly in the ALG after 6 weeks of treatment and after 12 weeks of follow-up compared with the PLG. The QoL results showed a significant improvement in the ALG compared with the PLG, which continued after 12 weeks. VAS results significantly decrease, hand grip strength significantly improved, and cetirizine intake significantly decreased post-treatment in the ALG relative to the PLG. HILT combined with cetirizine seems more effective in patients with post-burn pruritus than a placebo laser procedure with cetirizine.

  9. Continuation of full-scale three-dimensional numerical experiments on high-intensity particle and laser beam-matter interactions

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Warren, B.

    2012-12-01

    We present results from the grant entitled, Continuation of full-scale three-dimensional numerical experiments on high-intensity particle and laser beam-matter interactions. The research significantly advanced the understanding of basic high-energy density science (HEDS) on ultra intense laser and particle beam plasma interactions. This advancement in understanding was then used to to aid in the quest to make 1 GeV to 500 GeV plasma based accelerator stages. The work blended basic research with three-dimensions fully nonlinear and fully kinetic simulations including full-scale modeling of ongoing or planned experiments. The primary tool was three-dimensional particle-in-cell simulations. The simulations provided a test bed for theoretical ideas and models as well as a method to guide experiments. The research also included careful benchmarking of codes against experiment. High-fidelity full-scale modeling provided a means to extrapolate parameters into regimes that were not accessible to current or near term experiments, thereby allowing concepts to be tested with confidence before tens to hundreds of millions of dollars were spent building facilities. The research allowed the development of a hierarchy of PIC codes and diagnostics that is one of the most advanced in the world.

  10. Stimulated Raman backscattering at high laser intensities

    Energy Technology Data Exchange (ETDEWEB)

    Skoric, M.M. [Vinca Inst. of Nuclear Sciences, Belgrade (Yugoslavia); Tajima, Toshiki; Sasaki, Akira; Maluckov, A.; Jovanovic, M.

    1998-03-01

    Signatures of Stimulated Raman backscattering of a short-pulse high-intensity laser interacting with an underdense plasma are discussed. We introduce a nonlinear three-wave interaction model that accounts for laser pump depletion and relativistic detuning. A mechanism is revealed based on a generic route to chaos, that predicts a progressive increase of the backscatter complexity with a growing laser intensity. Importance of kinetic effects is outlined and demonstrated in fluid-hybrid and particle simulations. As an application, we show that spectral anomalies of the backscatter, predicted by the above model, are consistent with recent sub-picosecond, high-intensity laser gas-target measurements at Livermore and elsewhere. Finally, a recently proposed scheme for generation of ultra-short, low-prepulse laser pulses by Raman backscattering in a thin foil target, is shown. (author)

  11. Using ultra-short pulses to determine particle size and density distributions

    NARCIS (Netherlands)

    Lee, Christopher James; van der Slot, Petrus J.M.; Boller, Klaus J.

    2007-01-01

    We analyze the time dependent response of strongly scattering media (SSM) to ultra-short pulses of light. A random walk technique is used to model the optical scattering of ultra-short pulses of light propagating through media with random shapes and various packing densities. The pulse spreading was

  12. Effect of high-intensity laser therapy in the management of myofascial pain syndrome of the trapezius: a double-blind, placebo-controlled study.

    Science.gov (United States)

    Dundar, Umit; Turkmen, Utku; Toktas, Hasan; Solak, Ozlem; Ulasli, Alper Murat

    2015-01-01

    Myofascial pain syndrome (MPS) of the trapezius muscle is one of the main causes of neck pain. In this randomized, double-blind study, we evaluated the effects of high-intensity laser therapy (HILT) in female patients with chronic MPS of the trapezius muscle. The patients were assigned to two groups. The HILT group was treated with HILT and exercise, and the sham therapy group was treated with placebo HILT and exercise. The patients were assessed for pain, cervical active range of motion, disability, and quality of life. Evaluations were performed before treatment (week 0) and after treatment (weeks 4 and 12). Both groups showed significant improvement in all parameters at weeks 4 and 12. However, in a comparison of the percentage changes in the parameters at weeks 4 and 12 relative to pretreatment values, the HILT group showed greater improvement in pain scores, the neck disability index, and several subparts of the short-form 36 health survey (SF-36) (physical functioning, role limitations due to physical functioning, bodily pain, general health perceptions, social functioning, and role limitations due to emotional problems) than did the sham therapy group. We conclude that HILT is an effective therapeutic method in the treatment of patients with chronic MPS of the trapezius muscle.

  13. Short-term effects of high-intensity laser therapy, manual therapy, and Kinesio taping in patients with subacromial impingement syndrome.

    Science.gov (United States)

    Pekyavas, Nihan Ozunlu; Baltaci, Gul

    2016-08-01

    Subacromial impingement syndrome (SAIS) is a major contributing factor of shoulder pain; and treatment approaches (Kinesio® taping [KT], Exercise [EX], manual therapy [MT], and high-intensity laser therapy [HILT]) have been developed to treat the pain. The key objective of this study was to compare the effects of KT, MT, and HILT on the pain, the range of motion (ROM), and the functioning in patients with SAIS. Seventy patients with SAIS were randomly divided into four groups based on the treatment(s) each group received [EX (n = 15), KT + EX (n = 20), MT + KT + EX (n = 16), and MT + KT + HILT + EX (n = 19)]. All the patients were assessed before and at the end of the treatment (15th day). The main outcome assessments included the evaluation of severity of pain by visual analogue scale (VAS) and shoulder flexion, abduction, and external rotation ROM measurements by a universal goniometry. Shoulder pain and disability index (SPADI) was used to measure pain and disability associated with shoulder pathology. Statistically significant differences were found in the treatment results of all parameters in MT + KT + EX and HILT + MT + KT + EX groups (p effective in minimizing pain and disability and increasing ROM in patients with SAIS. Further studies with follow-up periods are required to determine the advantages of these treatments conclusively.

  14. Particle sources with high-intensity lasers: a tool for plasma diagnostics and an innovative source for applications; Sources de particules avec des lasers de haute intensite: un outil pour les diagnostics plasma et une source innovante pour les applications

    Energy Technology Data Exchange (ETDEWEB)

    Fritzler, S

    2003-09-15

    This work is an experimental study on particle generation with high-intensity lasers. This document is divided into 4 parts, whereas the first is dedicated to theoretical basics of particle generation and acceleration mechanisms during relativistic laser plasma interactions, the 3 other parts cover experimental studies on neutron, electron as well as proton generation. In the first part basic laser and plasma characteristics will be introduced as well as physical processes of interest during the interaction of a relativistic high-intensity laser with an underdense / overdense plasma. In the second part we introduce methodological basics of neutron generation by D(d,n)He{sup 3} reactions since this can reveal information about ion kinetics and possible ion heating mechanisms in plasmas. Subsequently the set-up for this experiment, pursued in the underdense regime, will be described in detail. The experimental results will be discussed for the gas jet interaction as well as for the beam target model since it was deduced that plasma ions are heated during the interaction to fusion temperatures of about 1 keV. The third part describes the generation of an electron beam with an energy up to 200 MeV in a new regime termed 'forced laser Wakefield'. Here, the presented experimental results were for the first time fully explained and even extended by the numerical modelling of this interaction in terms of energy, yield, angular divergence, emittance as well as bunch length of this electron beam. In the last part we present a 10 MeV proton beam generation using foil targets and a 10 Hz laser. Again the kinematic simulation of this experiment is in agreement with the experimental results by means of yield and angular divergence.

  15. Generation of a Periodic Series of High-Power Ultra-Short Pulses in a Gyro-TWT with a Bleachable Cyclotron Absorber in the Feedback Circuit

    Science.gov (United States)

    Vilkov, M. N.; Ginzburg, N. S.; Denisov, G. G.; Zotova, I. V.; Sergeev, A. S.

    2016-01-01

    We demonstrate the possibility of forming a periodic series of ultra-short pulses, which has a peak power exceeding significantly the radiation power in stationary regimes, in a gyroresonance traveling-wave tube (gyro-TWT) with a bleachable cyclotron absorber in the feedback circuit. The mechanism of pulsed generation is similar to the method of passive mode locking, which is used widely in laser physics.

  16. High-intensity, high-contrast laser pulses generated from the fully diode-pumped Yb:glass laser system POLARIS.

    Science.gov (United States)

    Hornung, Marco; Keppler, Sebastian; Bödefeld, Ragnar; Kessler, Alexander; Liebetrau, Hartmut; Körner, Jörg; Hellwing, Marco; Schorcht, Frank; Jäckel, Oliver; Sävert, Alexander; Polz, Jens; Arunachalam, Ajay Kawshik; Hein, Joachim; Kaluza, Malte C

    2013-03-01

    We report on the first generation of high-contrast, 164 fs duration pulses from the laser system POLARIS reaching focused peak intensities in excess of 2×10(20) W/cm2. To our knowledge, this is the highest peak intensity reported so far that has been achieved with a diode-pumped, solid-state laser. Several passive contrast enhancement techniques have been specially developed and implemented, achieving a relative prepulse intensity smaller than 10(-8) at t=-30 ps before the main pulse. Furthermore a closed-loop adaptive-optics system has been installed. Together with angular chirp compensation, this method has led to a significant reduction of the focal spot size and an increase of the peak intensity.

  17. Laser-driven proton sources and their applications: femtosecond intense laser plasma driven simultaneous proton and x-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nishiuchi, M; Daido, H; Yogo, A; Sagisaka, A; Ogura, K; Orimo, S; Mori, M; Ma, J; Pirozhkov, A S; Kiriyama, H; Kanazawa, S; Kondo, S; Yamamoto, Y; Shimoura, T; Tanoue, M; Nakai, Y; Akutsu, A; Nagashima, A; Bulanov, S V; Esirkepov, T Z [Advanced Photon Research Center, JAEA, Kizugawa-shi, Kyoto (Japan)], E-mail: nishiuchi.mamiko@jaea.go.jp (and others)

    2008-05-01

    We have performed simultaneous proton and X-ray imaging with an ultra-short and high-intensity Ti: Sap laser system. More than 10{sup 10} protons, whose maximum energy reaches 2.5 MeV, were delivered within a {approx}ps bunch. At the same time, keV X-ray is generated at almost the same place where protons are emitted. We have performed the simultaneous imaging of the copper mesh by using proton and x-ray beams, in practical use of the characteristics of the laser produced plasma that it can provide those beams simultaneously without any serious problems on synchronization.

  18. Femtosecond laser-matter interaction theory, experiments and applications

    CERN Document Server

    Gamaly, Eugene G

    2011-01-01

    Basics of Ultra-Short Laser-Solid InteractionsSubtle Atomic Motion Preceding a Phase Transition: Birth, Life and Death of PhononsUltra-Fast Disordering by fs-Lasers: Superheating Prior to Entropy CatastropheAblation of SolidsUltra-Short Laser-Matter Interaction Confined Inside a Bulk of Transparent SolidApplications of Ultra-Short Laser-Matter InteractionsConclusion Remarks.

  19. Generation and transport of fast electrons in the interaction of high intensity laser with matter; Generation et transport des electrons rapides dans l'interaction laser-matiere a haut flux

    Energy Technology Data Exchange (ETDEWEB)

    Popescu, H

    2005-10-15

    The general context of this study is the Inertial Confinement for thermonuclear controlled fusion and, more precisely, the Fast Igniter (FI). In this context the knowledge of the generation and transport of fast electrons is crucial. This thesis is an experimental study of the generation and transport of fast electrons in the interaction of a high intensity laser ({>=} 10{sup 19} W/cm{sup 2}) with a solid target. The main diagnostic used here is the transition radiation. This radiation depends on the electrons which produce it and thus it gives important information on the electrons: energy, temperature, propagation geometry, etc. The spectral, temporal and spatial analysis permitted to put in evidence the acceleration of periodic electron bunches which, in this case, emit a Coherent Transition Radiation (CTR). During this thesis we have developed some theoretical models in order to explain the experimental results. We find this way two kinds of electron bunches, emitted either at the laser frequency ({omega}{sub 0}), either at the double of this frequency (2{omega}{sub 0}), involving several acceleration mechanisms: vacuum heating / resonance absorption and Lorentz force, respectively. These bunches are also observed in the PIC (particle-in-cell) simulations. The electron temperature is of about 2 MeV in our experimental conditions. The electrons are emitted starting from a point source (which is the laser focal spot) and then propagate in a ballistic way through the target. In some cases they can be re-injected in the target by the electrostatic field from the target edges. This diagnostic is only sensitive to the coherent relativistic electrons, which explains the weak total energy that they contain (about a few mJ). The CTR signal emitted by those fast electrons is largely dominating the signal emitted by the less energetic electrons, even if they contain the major part of the energy (about 1 J). (author)

  20. High Intensity Physics

    Science.gov (United States)

    Marklund, M.; Brodin, G.; Lundin, J.; Ilderton, A.

    2009-11-01

    The capability to produce high field strengths, and thereby obtain a new means for doing fundamental physics, has over the last thirty years taken great leaps forward. Both superconducting cavities as well ultra-intense lasers can now reach field strengths of the order 50 MV/m (stationary) and 1012 V/m (peak value, time-dependent field), respectively. Here we will describe a collection of problems that catches the flavor of the nonlinear quantum vacuum and the possibility to use high field strengths as a low-energy probe of fundamental physics.

  1. Strong-field QED processes in short laser pulses. One- and two-photon Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Seipt, Daniel

    2012-12-20

    The purpose of this thesis is to advance the understanding of strong-field QED processes in short laser pulses. The processes of non-linear one-photon and two-photon Compton scattering are studied, that is the scattering of photons in the interaction of relativistic electrons with ultra-short high-intensity laser pulses. These investigations are done in view of the present and next generation of ultra-high intensity optical lasers which are supposed to achieve unprecedented intensities of the order of 10{sup 24} W/cm{sup 2} and beyond, with pulse lengths in the order of some femtoseconds. The ultra-high laser intensity requires a non-perturbative description of the interaction of charged particles with the laser field to allow for multi-photon interactions, which is beyond the usual perturbative expansion of QED organized in powers of the fine structure constant. This is achieved in strong-field QED by employing the Furry picture and non-perturbative solutions of the Dirac equation in the presence of a background laser field as initial and final state wave functions, as well as the laser dressed Dirac-Volkov propagator. The primary objective is a realistic description of scattering processes with regard to the finite laser pulse duration beyond the common approximation of infinite plane waves, which is made necessary by the ultra-short pulse length of modern high-intensity lasers. Non-linear finite size effects are identified, which are a result of the interplay between the ultra-high intensity and the ultra-short pulse length. In particular, the frequency spectra and azimuthal photon emission spectra are studied emphasizing the differences between pulsed and infinite laser fields. The proper description of the finite temporal duration of the laser pulse leads to a regularization of unphysical infinities (due to the infinite plane-wave description) of the laser-dressed Dirac-Volkov propagator and in the second-order strong-field process of two-photon Compton

  2. The Discovery and Mass Measurement of a New Ultra-short-period Planet: EPIC 228732031b

    DEFF Research Database (Denmark)

    Dai, Fei; Winn, Joshua N.; Gandolfi, Davide

    2017-01-01

    We report the discovery of a new ultra-short-period planet and summarize the properties of all such planets for which the mass and radius have been measured. The new planet, EPIC 228732031b, was discovered in K2 Campaign 10. It has a radius of {1.81}-0.12+0.16 {R}\\oplus and orbits a G dwarf with ...

  3. Validity of (Ultra-)Short Recordings for Heart Rate Variability Measurements

    NARCIS (Netherlands)

    Muñoz Venegas, M.L.; van Roon, A.; Riese, H.; Thio, C.; Oostenbroek, E.; Westrik, I.; de Geus, E.J.C.; Gansevoort, R.; Lefrandt, J.; Nolte, I.M.; Snieder, H.

    2015-01-01

    Objectives In order to investigate the applicability of routine 10s electrocardiogram (ECG) recordings for time-domain heart rate variability (HRV) calculation we explored to what extent these (ultra-)short recordings capture the "actual" HRV. Methods The standard deviation of normal-to-normal

  4. The relationship between ultra-short telomeres, aging of articular cartilage and the development of human hip osteoarthritis

    DEFF Research Database (Denmark)

    Harbo, M; Delaisse, J M; Kjaersgaard-Andersen, P

    2013-01-01

    Ultra-short telomeres caused by stress-induced telomere shortening are suggested to induce chondrocyte senescence in human osteoarthritic knees. Here we have further investigated the role of ultra-short telomeres in the development of osteoarthritis (OA) and in aging of articular cartilage in human...

  5. Illumination Effect of Laser Light in Foggy Objects Using an Active Imaging System

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Seong-Ouk; Park, Seung-Kyu; Ahn, Yong-Jin; Baik, Sung-Hoon; Choi, Young-Soo; Jeong, Kyung-Min [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    Active imaging techniques usually provide improved image information when compared to passive imaging techniques. Active vision is a direct visualization technique using an artificial illuminant. Range-gated imaging (RGI) technique is one of active vision technologies. The RGI technique extracts vision information by summing time sliced vision images. In the RGI system, objects are illuminated for ultra-short time by a high intensity illuminant and then the light reflected from objects is captured by a highly sensitive image sensor with the exposure of ultra-short time. The Range-gated imaging is an emerging technology in the field of surveillance for security application, especially in the visualization of darken night or foggy environment. Although RGI viewing was discovered in the 1960's, this technology is currently more applicable by virtue of the rapid development of optical and sensor technologies, such as highly sensitive imaging sensor and ultra-short pulse laser light. Especially, this system can be adopted in robot-vision system by virtue of the compact system configuration. During the past decades, several applications of this technology have been applied in target recognition and in harsh environments, such as fog, underwater vision. Also, this technology has been demonstrated range imaging based on range-gated imaging. Laser light having a short pulse width is usually used for the range-gated imaging system. In this paper, an illumination effect of laser light in foggy objects is studied using a range-gated imaging system. The used imaging system consists of an ultra-short pulse (0.35 ns) laser light and a gated imaging sensor. The experiment is carried out to monitor objects in a box filled by fog. In this paper, the effects by fog particles in range-gated imaging technique are studied. Edge blurring and range distortion are the generated by fog particles.

  6. Direct Measurements of Space-Charge-Potential in High Intensity H- Beam with Laser Based Photo Neutralization Method

    CERN Document Server

    Lee, S; Ikegami, M; Toyama, T

    2005-01-01

    Transverse profiles of H- beams can be observed by scanning a laser wire across the ion beam and detect the pulse of photo detached electrons. In addition, laser based photo neutralization method have a capability of direct space-charge-potential measurement by investigate the energy distribution of collected electrons. The kinetic energy of photo detached electron corresponds to the ion velocity and space potential at stripped location. The space-charge-potential in H- beam can be measured by scanning the bias potential of repeller grid in front of Faraday cup. In this paper, an available method to observe the space-charge-potential and preliminary experimental results with Nd:YAG laser in KEK DTL1 (J-PARC) are described.

  7. Measurement of 2l-nl' x-ray transitions from approximately 1 microm Kr clusters irradiated by high-intensity femtosecond laser pulses.

    Science.gov (United States)

    Hansen, S B; Fournier, K B; Faenov, A Ya; Magunov, A I; Pikuz, T A; Skobelev, I Yu; Fukuda, Y; Akahane, Y; Aoyama, M; Inoue, N; Ueda, H; Yamakawa, K

    2005-01-01

    X-ray line emission from 2l-nl' transitions in Ne-like Kr and nearby ions has been observed from approximately 1 microm Kr clusters irradiated by fs-scale laser pulses at the JAERI facility in Kyoto, Japan. The incident laser intensity reached 10(19) W/cm2, with pulse energies from 50 to 300 mJ and pulse durations from 30 to 500 fs. The dependence of the x-ray spectral features and intensity on the incident laser intensity is rather weak, indicating that the 1-2 ps cluster lifetimes limit the number of ions beyond Ne-like Kr that can be produced by collisional ionization. Lines from F- to Al-like Kr emitted from the cluster plasmas have been identified using data from the relativistic multiconfiguration flexible atomic code. A collisional-radiative model based on these data has been constructed and used to determine that the cluster plasma has electron densities near 10(22) cm(-3), temperatures of a few hundred eV, and hot electron fractions of a few percent.

  8. Accelerators for high intensity beams

    CERN Document Server

    Chou, Weiren

    2014-01-01

    As particle accelerators strive forever increasing performance, high intensity particle beams become one of the critical demands requested across the board by a majority of accelerator users (proton, electron and ion) and for most applications. Much effort has been made by our community to pursue high intensity accelerator performance on a number of fronts. Recognizing its importance, we devote this volume to Accelerators for High Intensity Beams. High intensity accelerators have become a frontier and a network for innovation. They are responsible for many scientific discoveries and technological breakthroughs that have changed our way of life, often taken for granted. A wide range of topics is covered in the fourteen articles in this volume.

  9. [Assessment of rehabilitation progress in patients with cervical radicular pain syndrome after application of high intensity laser therapy - HILT and Saunders traction device].

    Science.gov (United States)

    Haładaj, Robert; Pingot, Julia; Pingot, Mariusz

    2015-07-01

    Osteoarthritis of the spine is a major global health problem, it is an epidemic of our times. It affects all parts of the spine, but the hardest to treat is its cervical region. The cervical spine is most mobile, delicate and sensitive to any load. It requires special care in conservative treatment. To date the selection of effective therapeutic approaches has been controversial. The aim of the study was to assess the progress of rehabilitation in patients with cervical radicular pain syndrome after using two different methods of treatment: HILT and spinal axial traction with the use of Saunders device. The randomized study included 150 patients (81 women and 69 men, aged 24-67 years, mean age 45.5) divided into two groups of 75 patients each with characteristic symptoms of radicular pain. The measurement of the range of cervical spine movement of the cervical spine, visual analog scale for pain - VAS and a NDI questionnaire (Neck Disability Index - Polish version) - an indicator of functional disorders - were used to evaluate the effectiveness of the two different therapies. The results obtained by Saunders method remained significantly higher than those obtained when HILT laser therapy was used for most of the examined parameters. A thorough analysis of the results showed greater analgesic efficacy, improved global mobility and reduced functional impairment in patients treated with Saunders method. Both therapeutic methods manifest analgesic effect and a positive impact on the improvement of range of cervical spine movement in patients with radicular pain in this spine region. HILT laser therapy and Saunders traction device reduce neck disability index in the treated patients. © 2015 MEDPRESS.

  10. Mechanism and computational model for Lyman-α-radiation generation by high-intensity-laser four-wave mixing in Kr-Ar gas

    Science.gov (United States)

    Louchev, Oleg A.; Bakule, Pavel; Saito, Norihito; Wada, Satoshi; Yokoyama, Koji; Ishida, Katsuhiko; Iwasaki, Masahiko

    2011-09-01

    We present a theoretical model combined with a computational study of a laser four-wave mixing process under optical discharge in which the non-steady-state four-wave amplitude equations are integrated with the kinetic equations of initial optical discharge and electron avalanche ionization in Kr-Ar gas. The model is validated by earlier experimental data showing strong inhibition of the generation of pulsed, tunable Lyman-α (Ly-α) radiation when using sum-difference frequency mixing of 212.6 nm and tunable infrared radiation (820-850 nm). The rigorous computational approach to the problem reveals the possibility and mechanism of strong auto-oscillations in sum-difference resonant Ly-α generation due to the combined effect of (i) 212.6-nm (2+1)-photon ionization producing initial electrons, followed by (ii) the electron avalanche dominated by 843-nm radiation, and (iii) the final breakdown of the phase matching condition. The model shows that the final efficiency of Ly-α radiation generation can achieve a value of ˜5×10-4 which is restricted by the total combined absorption of the fundamental and generated radiation.

  11. Time-resolved investigations of the fragmentation dynamic of H{sub 2} (D{sub 2}) in and with ultra-short laser pulses; Zeitaufgeloeste Untersuchungen zur Fragmentationsdynamik von H{sub 2} (D{sub 2}) in ultra-kurzen Laserpulsen

    Energy Technology Data Exchange (ETDEWEB)

    Ergler, T.

    2006-07-19

    In course of this work pump-probe experiments aimed to study ultrafast nuclear motion in H{sub 2} (D{sub 2}) fragmentation by intense 6-25 fs laser pulses have been carried out. In order to perform time-resolved measurements, a Mach-Zehnder interferometer providing two identical synchronized laser pulses with the time-delay variable from 0 to 3000 fs with 300 as accuracy and long-term stability has been built. The laser pulses at the intensities of up to 10{sup 15} W/cm{sup 2} were focused onto a H{sub 2} (D{sub 2}) molecular beam leading to the ionization or dissociation of the molecules, and the momenta of all charged reactions fragments were measured with a reaction microscope. With 6-7 fs pulses it was possible to probe the time evolution of the bound H{sup +}{sub 2} (D{sup +}{sub 2}) nuclear wave packet created by the first (pump) laser pulse, fragmenting the molecule with the second (probe) pulse. A fast delocalization, or ''collapse'', and subsequent ''revival'' of the vibrational wave packet have been observed. In addition, the signatures of the ground state vibrational excitation in neutral D{sub 2} molecule have been found, and the dominance of a new, purely quantum mechanical wave packet preparation mechanism (the so-called ''Lochfrass'') has been proved. In the experiments with 25 fs pulses the theoretically predicted enhancement of the ionization probability for the dissociating H{sup +}{sub 2} molecular ion at large internuclear distances has been detected for the first time. (orig.)

  12. Numerical Study of K{\\alpha} X-ray Emission from Multi-layered Cold and Compressed Targets Irradiated by Ultrashort Laser Pulses

    CERN Document Server

    Kelardeh, Hamed Koochaki

    2015-01-01

    In this paper the generation of K{\\alpha} X-ray produced by interaction of ultrashort laser pulses with metal targets has been studied numerically. Several targets were assumed to be irradiated by high intensity ultra-short laser pulses for the calculations. Using Maxwell Boltzmann distribution function for hot electron and applying an analytical model, the number of K{\\alpha} photons were calculated as a function of hot electron temperature, target thickness and K-shell ionization cross section. Also, simulation results of K{\\alpha} yield versus target thickness variations from two and three layer metals have been presented. These calculations are useful for optimization of X-ray yield produced by irradiation of metal targets with high intensity laser pulses. We also generalized this model and present simulation results on K{\\alpha} fluorescence measurement produced by fast electron propagation in shock compressed materials.

  13. Synergistic effect of high-intensity focused ultrasound and low-fluence Q-switched Nd:YAG laser in the treatment of the aging neck and décolletage.

    Science.gov (United States)

    Nam, Jae-Hui; Choi, Young-Jun; Lim, Jae Yun; Min, Joon Hong; Kim, Won-Serk

    2017-01-01

    High-intensity focused ultrasound (HIFU) is regarded as an effective skin-lifting device; however, literature regarding treatment of the aging neck and décolletage with HIFU is scarce. Our study aimed to evaluate the efficacy of combination with HIFU and low-fluence Q-switched Nd:YAG (LQSNY) laser on the aging neck and décolletage. Nineteen women were assessed. HIFU at two visits and LQSNY laser at six visits were used to irradiate the neck and chest. At week 16, improvements were rated using the Dedo classification, Fabi/Bolton Chest Wrinkle Scale (FBCWS), and Global Aesthetic Improvement Scales (GAIS). Erythema and melanin indices (EMIs) and cervicomental angle were measured. Subject GAIS and satisfaction were evaluated at follow-up visits. At week 16, neck sagging and chest rhytides were improved on Dedo classification and FBCWS, respectively. Pigmentation and rhytides of the neck and chest were rated as improved in 30 % or more of the subjects by physician GAIS and in approximately 80 % of the subjects by subject GAIS. The above differences seemed to be attributable to the initial expectation level and mild severity pertaining to dress custom in Korea. Eighty-four percent of subjects were satisfied with treatment outcomes. EMIs were decreased on the chest. The combination of HIFU and LQSNY is an effective treatment option to mitigate rhytides and pigmentation of the neck and décolletage.

  14. Quantum preservation of the measurements precision using ultra-short strong pulses in exact analytical solution

    Science.gov (United States)

    Berrada, K.; Eleuch, H.

    2017-09-01

    Various schemes have been proposed to improve the parameter-estimation precision. In the present work, we suggest an alternative method to preserve the estimation precision by considering a model that closely describes a realistic experimental scenario. We explore this active way to control and enhance the measurements precision for a two-level quantum system interacting with classical electromagnetic field using ultra-short strong pulses with an exact analytical solution, i.e. beyond the rotating wave approximation. In particular, we investigate the variation of the precision with a few cycles pulse and a smooth phase jump over a finite time interval. We show that by acting on the shape of the phase transient and other parameters of the considered system, the amount of information may be increased and has smaller decay rate in the long time. These features make two-level systems incorporated in ultra-short, of-resonant and gradually changing phase good candidates for implementation of schemes for the quantum computation and the coherent information processing.

  15. Adaptive ultra-short-term wind power prediction based on risk assessment

    DEFF Research Database (Denmark)

    Xue, Yusheng; Yu, Chen; Li, Kang

    2016-01-01

    A risk assessment based adaptive ultra-short-term wind power prediction (USTWPP) method is proposed in this paper. The method first extracts features from the historical data, and split every wind power time series (WPTS) into several subsets defined by their stationary patterns. A WPTS that does...... not match with any of the stationary patterns is then included into a subset of non-stationary patterns. Every WPTS subset is then related to a USTWPP model which is specially selected and optimized offline based on the proposed risk assessment index. For on-line applications, the pattern of the last short...... WPTS is first recognized, and the relevant prediction model is applied for USTWPP. Experimental results confirm the efficacy of the proposed method....

  16. Complex {PT}-symmetric extensions of the nonlinear ultra-short light pulse model

    Science.gov (United States)

    Yan, Zhenya

    2012-11-01

    The short pulse equation u_{xt}=u+\\frac{1}{2}(u^2u_x)_x is PT symmetric, which arises in nonlinear optics for the ultra-short pulse case. We present a family of new complex PT-symmetric extensions of the short pulse equation, i[(iu_x)^{\\sigma }]_t=au+bu^m+ic[u^n(iu_x)^{\\epsilon }]_x \\,\\, (\\sigma ,\\, \\epsilon ,\\,a,\\,b,\\,c,\\,m,\\,n \\in {R}), based on the complex PT-symmetric extension principle. Some properties of these equations with some chosen parameters are studied including the Hamiltonian structures and exact solutions such as solitary wave solutions, doubly periodic wave solutions and compacton solutions. Our results may be useful to understand complex PT-symmetric nonlinear physical models. This article is part of a special issue of Journal of Physics A: Mathematical and Theoretical devoted to ‘Quantum physics with non-Hermitian operators’.

  17. Validity of the ithlete™ Smart Phone Application for Determining Ultra-Short-Term Heart Rate Variability

    Science.gov (United States)

    Flatt, Andrew A.; Esco, Michael R.

    2013-01-01

    The purpose of this investigation was to cross-validate the ithlete™ heart rate variability smart phone application with an electrocardiograph for determining ultra-short-term root mean square of successive R-R intervals. The root mean square of successive R-R intervals was simultaneously determined via electrocardiograph and ithlete™ at rest in twenty five healthy participants. There were no significant differences between the electrocardiograph and ithlete™ derived root mean square of successive R-R interval values (p > 0.05) and the correlation was near perfect (r = 0.99, p study lays groundwork for future research determining the efficacy of ithlete™ for reflecting athletic training status over a chronic conditioning period. PMID:24511344

  18. Detection of mental stress due to oral academic examination via ultra-short-term HRV analysis.

    Science.gov (United States)

    Castaldo, R; Xu, W; Melillo, P; Pecchia, L; Santamaria, L; James, C

    2016-08-01

    Mental stress may cause cognitive dysfunctions, cardiovascular disorders and depression. Mental stress detection via short-term Heart Rate Variability (HRV) analysis has been widely explored in the last years, while ultra-short term (less than 5 minutes) HRV has been not. This study aims to detect mental stress using linear and non-linear HRV features extracted from 3 minutes ECG excerpts recorded from 42 university students, during oral examination (stress) and at rest after a vacation. HRV features were then extracted and analyzed according to the literature using validated software tools. Statistical and data mining analysis were then performed on the extracted HRV features. The best performing machine learning method was the C4.5 tree algorithm, which discriminated between stress and rest with sensitivity, specificity and accuracy rate of 78%, 80% and 79% respectively.

  19. Auto-Segmentation of Bone in MRI-only Based Radiotherapy Using Ultra Short Echo Time

    DEFF Research Database (Denmark)

    Edmund, J. M.; Kjer, Hans Martin; Hansen, R. H.

    2012-01-01

    Purpose/Objective: Treatment planning based on MRI-only has shown a promising potential if bulk density assignment for tissue, air and bone are taken into consideration. A major issue is the need to autosegment these bulk tissue structures in the MRI image to make the approach feasible. This is....... First, a TE1-2 image is created by subtracting TE2 from TE1 (figure, row 1). This image is then masked with a binary image of TE2 creating a TE1-2* image with a more well defined outer contour and discrimination between air and tissue (figure, row 2). Two different filters based on the most insensitive......, however, complicated by an extremely short T2 relaxation time (~ 1 ms) of the bone resulting in no signal using conventional MRI sequences. Here, we present an approach adapted from PET/MRI attenuation maps to automatically segment the bone using MRI sequences based on ultra short echo times (UTE...

  20. Methods for Free-Space Ultra-Short Solitary EMP Measurement

    Directory of Open Access Journals (Sweden)

    Eva Kadlecova

    2006-01-01

    Full Text Available There are some suitable methods for ultra-short solitary electromagnetic pulses (EMP measurement. The EMPs are generated by high power microwave generators. The characteristic of EMPs is high power level (Pmax = 250 MW and very short time duration (tp Î ns. Special requirements for measurement methods are placed because of the specific EMPs properties.Two suitable methods for this application are presented in the paper. The first – calorimetric method, utilizes the thermal impacts of microwave absorption. The second method presented – magneto-optic method, use the Faraday’s magneto-optic effect as a sensor principle. It was realized combined calorimetric sensor and there were made some experimental EMP measurements with good results. The sensor utilizing magneto-optic method is in development.

  1. Clinical and anti-inflammatory effects of ultra-short preseasonal vaccine to Parietaria in asthma.

    Science.gov (United States)

    Scichilone, Nicola; Scalici, Vincenza; Arrigo, Rita; Bellia, Vincenzo

    2013-08-01

    The ultra-short course preseasonal allergy vaccine, containing the adjuvant monophosphoryl lipid A (MPL), is effective in treating allergic symptoms; however, the efficacy in controlling asthmatics symptoms has not been fully demonstrated. We aimed at evaluating whether the ultra-short preseasonal course of immunotherapy contributes to asthma control. Four subcutaneous injections of the active product (Pollinex Quattro) were administered, before the pollen season, to 20 Parietaria-sensitive mild, untreated asthmatics (M/F: 12/8; age: 38 ± 14 years). After the screening visit (visit 1), asthma control was assessed by the Asthma Control Test (ACT) immediately before the first (visit 2) and immediately after the last (visit 5) injections, as well as during the pollen season (visit 6). Bronchial and alveolar exhaled nitric oxide (NO) concentrations were also measured. Nine Parietaria-sensitive mild asthmatics (M/F: 3/6; age: 40 ± 12 years) served as untreated controls. The ACT remained constant during allergen exposure in specific immunotherapy (SIT)-treated asthmatics (visit 2: 22 ± 3.2; visit 5: 23 ± 2.8; visit 6: 22 ± 3.6; analysis of variance [ANOVA], p = 0.47), whereas it dropped during pollen exposure in controls (visit 2: 20 ± 2.5; visit 5: 21 ± 2.8; visit 6: 16 ± 5.7; ANOVA, p = 0.01). The forced expiratory NO (FENO) values significantly increased during pollen exposure in both groups; however, the alveolar NO concentrations remained stable in SIT-treated asthmatics (p = 0.11), whereas they doubled in controls (p = 0.01). The current findings show that the preseasonal vaccine adjuvated with MPL contributes to the maintenance of control of asthma during the pollen season.

  2. Distal Duodenogastrostomy or Proximal Jejunogastrostomy in the Management of Ultra-Short Bowel.

    Science.gov (United States)

    Hofker, Tjipke Olivier; Kaijser, Mirjam Anna; Nieuwenhuijs, Vincent B; Lange, Johan Frederick Michel; Hofker, Hendrik Sijbrand

    2017-12-22

    Inflammatory bowel disease, vascular disease, volvulus, adhesions, or abdominal trauma may necessitate extensive small-bowel resection resulting in an ultra-short distal duodenal or jejunal stump. If this distal duodenal or short jejunal stump is too short for stoma creation and bowel continuity restoration is hazardous or not possible at all, a distal duodenogastrostomy or proximal jejunogastrostomy in combination with drainage of the stomach is an option to prevent stump leakage. Although successful, this distal duodenogastrostomy has been described only in very few patients and in older records. We reintroduced this technique and describe a recent series of patients that confirms its usefulness in certain conditions. The technique of the distal duodenogastrostomy or proximal jejunogastrostomy with gastric drainage was used for the management of the difficult distal duodenum stump in five critically ill patients undergoing extensive bowel resection. Four patients with small-bowel ischemia and one patient suffering from perforating Crohn's disease and small-bowel volvulus were treated  successfully. The gastrostomies were subsequently converted to a duodenotransversostomy (in two patients) or the patients underwent small-bowel transplantation (two patients). One patient still has a jejunogastrostomy just after the duodenal-jejunal transition. In all five patients, the distal duodenogastrostomy or proximal jejunogastrostomy in combination with gastric drainage functioned well up to restoration of bowel continuity. In one patient, distal duodenogastrostomy and transabdominal gastric drainage functioned well for 5 years. No anastomotic leakage occurred. This procedure provides a feasible solution for an ultra-short bowel at emergency laparotomy. It enhances the surgical armamentarium and provides treatment options for these patients that were perhaps previously deemed unsalvageable.

  3. Advances in high repetition rate, ultra-short, gigawatt laser systems for time-resolved spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    DiMauro, L.F.

    1991-12-31

    The objective of this article is to emphasize the current advances in the development of high-repetition rate amplifier pumps. Although this review highlights amplifier pump development, any recent data from achieved outputs via the tunable amplifier section is also discussed. The first section describes desirable parameters attributable to the pump amplifier while the rest of the article deals with specific examples for various options. The pump amplifiers can be characterized into two distinct classes; those achieving operation in the hundred hertz regime and those performing at repetition rates {ge}1kHz. 23 refs., 4 figs.

  4. Advances in high repetition rate, ultra-short, gigawatt laser systems for time-resolved spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    DiMauro, L.F.

    1991-01-01

    The objective of this article is to emphasize the current advances in the development of high-repetition rate amplifier pumps. Although this review highlights amplifier pump development, any recent data from achieved outputs via the tunable amplifier section is also discussed. The first section describes desirable parameters attributable to the pump amplifier while the rest of the article deals with specific examples for various options. The pump amplifiers can be characterized into two distinct classes; those achieving operation in the hundred hertz regime and those performing at repetition rates {ge}1kHz. 23 refs., 4 figs.

  5. LHC Report: reaching high intensity

    CERN Multimedia

    Jan Uythoven

    2015-01-01

    After both beams having been ramped to their full energy of 6.5 TeV, the last two weeks saw the beam commissioning process advancing on many fronts. An important milestone was achieved when operators succeeded in circulating a nominal-intensity bunch. During the operation, some sudden beam losses resulted in beam dumps at top energy, a problem that needed to be understood and resolved.   In 2015 the LHC will be circulating around 2800 bunches in each beam and each bunch will contain just over 1 x 1011 protons. Until a few days ago commissioning was taking place with single bunches of 5 x 109 protons. The first nominal bunch with an intensity of 1 x 1011 protons was injected on Tuesday, 21 April. In order to circulate such a high-intensity bunch safely, the whole protection system must be working correctly: collimators, which protect the aperture, are set at preliminary values known as coarse settings; all kicker magnets for injecting and extracting the beams are commissioned with beam an...

  6. Validity of (Ultra-Short Recordings for Heart Rate Variability Measurements.

    Directory of Open Access Journals (Sweden)

    M Loretto Munoz

    Full Text Available In order to investigate the applicability of routine 10s electrocardiogram (ECG recordings for time-domain heart rate variability (HRV calculation we explored to what extent these (ultra-short recordings capture the "actual" HRV.The standard deviation of normal-to-normal intervals (SDNN and the root mean square of successive differences (RMSSD were measured in 3,387 adults. SDNN and RMSSD were assessed from (ultrashort recordings of 10s(3x, 30s, and 120s and compared to 240s-300s (gold standard measurements. Pearson's correlation coefficients (r, Bland-Altman 95% limits of agreement and Cohen's d statistics were used as agreement analysis techniques.Agreement between the separate 10s recordings and the 240s-300s recording was already substantial (r = 0.758-0.764/Bias = 0.398-0.416/d = 0.855-0.894 for SDNN; r = 0.853-0.862/Bias = 0.079-0.096/d = 0.150-0.171 for RMSSD, and improved further when three 10s periods were averaged (r = 0.863/Bias = 0.406/d = 0.874 for SDNN; r = 0.941/Bias = 0.088/d = 0.167 for RMSSD. Agreement increased with recording length and reached near perfect agreement at 120s (r = 0.956/Bias = 0.064/d = 0.137 for SDNN; r = 0.986/Bias = 0.014/d = 0.027 for RMSSD. For all recording lengths and agreement measures, RMSSD outperformed SDNN.Our results confirm that it is unnecessary to use recordings longer than 120s to obtain accurate measures of RMSSD and SDNN in the time domain. Even a single 10s (standard ECG recording yields a valid RMSSD measurement, although an average over multiple 10s ECGs is preferable. For SDNN we would recommend either 30s or multiple 10s ECGs. Future research projects using time-domain HRV parameters, e.g. genetic epidemiological studies, could calculate HRV from (ultra-short ECGs enabling such projects to be performed at a large scale.

  7. High-intensity coherent FIR radiation from sub-picosecond electron bunches

    Energy Technology Data Exchange (ETDEWEB)

    Kung, P.H.; Lihn, Hung-chi; Wiedemann, H.; Bocek, D.

    1994-01-01

    A facility to generate high-intensity, ultra-short pulses of broad-band far-infrared radiation has been assembled and tested at Stanford. The device uses sub-picosecond relativistic electron bunches to generate coherent radiation through transition or synchrotron radiation in the far-infrared (FIR) regime between millimeter waves and wavelengths of about 100 {mu}m and less. Experimental results show a peak radiation power of greater than 0.33 MW within a micro-bunch and an average FIR radiation power of 4 mW. The average bunch length of 2856 micro-bunches within a 1 {mu}sec macro-pulse is estimated to be about 480 sec. Simulations experimental setup and results will be discussed.

  8. Born dry in the photoevaporation desert: Kepler's ultra-short-period planets formed water-poor

    Science.gov (United States)

    Lopez, Eric D.

    2017-11-01

    Recent surveys have uncovered an exciting new population of ultra-short-period (USP) planets with orbital periods less than a day. These planets typically have radii ≲1.5 R⊕, indicating that they likely have rocky compositions. This stands in contrast to the overall distribution of planets out to ˜100 d, which is dominated by low-density sub-Neptunes above 2 R⊕, which must have gaseous envelopes to explain their size. However, on the USP orbits, planets are bombarded by intense levels of photoionizing radiation and consequently gaseous sub-Neptunes are extremely vulnerable to losing their envelopes to atmospheric photoevaporation. Using models of planet evolution, I show that the rocky USP planets can easily be produced as the evaporated remnants of sub-Neptunes with H/He envelopes and that we can therefore understand the observed dearth of USP sub-Neptunes as a natural consequence of photoevaporation. Critically however, planets on USP orbits could often retain their envelopes if they are formed with very high-metallicity water-dominated envelopes. Such water-rich planets would commonly be ≳2 R⊕ today, which is inconsistent with the observed evaporation desert, indicating that most USP planets likely formed from water-poor material within the snow-line. Finally, I examine the special case of 55 Cancri e and its possible composition in the light of recent observations, and discuss the prospects for further characterizing this population with future observations.

  9. Phase engineered wavelength conversion of ultra-short optical pulses in TI:PPLN waveguides

    Science.gov (United States)

    Babazadeh, Amin; Nouroozi, Rahman; Sohler, Wolfgang

    2016-02-01

    A phase engineered all-optical wavelength converter for ultra-short pulses (down to 140 fs) in a Ti-diffused, periodically poled lithium niobate (Ti:PPLN) waveguide is proposed. The phase engineering, due to the phase conjugation between signal and idler (converted signal) pulses which takes place in the cascaded second harmonic generation and difference frequency generation (cSHG/DFG) based wavelength conversion, already leads to shorter idler pulses. The proposed device consists of an unpoled (passive) waveguide section beside of the PPLN waveguide section in order to compensate pulse broadening and phase distortion of the idler pulses induced by the wavelength conversion (in the PPLN section). For example numerical analysis shows that a 140 fs input signal pulse is only broadened by 1.6% in a device with a combination of 20 mm and 6 mm long periodically poled and unpoled waveguide sections. Thus, cSHG/DFG based wavelength converters of a bandwidth of several Tbits/s can be designed.

  10. Design of an ultra-short throw catadioptric projection lens with a freeform mirror

    Science.gov (United States)

    Gao, Yang; Cheng, Dewen; Xu, Chen; Wang, Yongtian

    2016-10-01

    To meet the requirements of the current projection display system. This paper present an ultra-short throw catadioptric projection lens with a freeform mirror. This catadioptric structure consists of two parts. The first part is a set of rotationally symmetrical refractive lenses and the second part is a freeform mirror. In our design, Texas Instruments's Digital Light Processing (DLP) is chosen as the image source. A 0.65inch DMD is employed as the spatial light modulator. The two parts of system are firstly designed respectively, and then they are combined for final design. And a three-dimensional direct design method is firstly employed to design the freeform mirror. The final designed projection lens composes of nine lenses and a XY polynomial mirror, of which the F number is 3.5, the focal length is 6.05mm, and the screen size is 60inch. The designed system achieves projected the display screen with a projection distance of 440mm, which the throw ratio is 0.29. Results show that the MTF of all the FOVs are over 30% at 66lp/mm. The maximum distortion is less than 4%. Due to the high optical performance and compact structure, this designed projection lens is suitable for household and educational applications.

  11. A hybrid approach for generating ultra-short bunches for advanced accelerator applications

    Energy Technology Data Exchange (ETDEWEB)

    Stratakis, Diktys [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-09-01

    Generation of electron beams with high phase-space density, short bunch length and high peak current is an essential requirement for future linear colliders and bright electron beam sources. Unfortunately, such bunches cannot be produced directly from the source since forces from the mutual repulsion of electrons would destroy the brilliance of the beam within a short distance. Here, we detail a beam dynamics study of an innovative two-stage compression scheme that can generate ultra-short bunches without degrading the beam quality. In the first stage, the beam is compressed with an advanced velocity bunching technique in which the longitudinal phase space is rotated so that electrons on the bunch tail become faster than electrons in the bunch head. In the second stage, the beam is further compressed with a conventional magnetic chicane. With the aid of numerical simulations we show that our two-staged scheme is capable to increase the current of a 50 pC bunch to a notable factor of 100 while the emittance growth can be suppressed to 1% with appropriate tailoring of the initial beam distribution.

  12. Design of an optical system in an ultra-short throw projector using the aspheric surfaces

    Science.gov (United States)

    Cheng, Xuemin; Wang, Yong; Hao, Qun

    2012-11-01

    The ultra-short throw projector with interactive function has been popular these days. To perform interactively, a pen is equipped, e.g., containing an infrared LED. To detect the movements of the pen, another optical system is needed. The optical systems used in these projectors need to achieve special performance qualities, especially a small distance between the projector and the screen while maintaining high optical performance and a large field of view (FOV). In this paper, an optical system to detect the movements of the pen is designed. We begin the design procedure with an existing optical system whose FOV is relatively small. To expand the FOV, an element is added to the existing system using the Wassermann-Wolf method for a pair of conjugate foci. Then a table of coordinates of points is gotten and fitted into two aspheric surfaces. CODE V is further used to optimize the performance of optical system. Manufacturing method of the optical system are taken into account as well.The f/number of the optical system is 1.1, the value of MTF (modulation transfer function) is more than 0.6 at 100 cycles/mm, FOV is 69°, object distance is 300 mm, and the maximum distortion is less than 4%.

  13. Ultra-Short-Term Wind Power Prediction Using a Hybrid Model

    Science.gov (United States)

    Mohammed, E.; Wang, S.; Yu, J.

    2017-05-01

    This paper aims to develop and apply a hybrid model of two data analytical methods, multiple linear regressions and least square (MLR&LS), for ultra-short-term wind power prediction (WPP), for example taking, Northeast China electricity demand. The data was obtained from the historical records of wind power from an offshore region, and from a wind farm of the wind power plant in the areas. The WPP achieved in two stages: first, the ratios of wind power were forecasted using the proposed hybrid method, and then the transformation of these ratios of wind power to obtain forecasted values. The hybrid model combines the persistence methods, MLR and LS. The proposed method included two prediction types, multi-point prediction and single-point prediction. WPP is tested by applying different models such as autoregressive moving average (ARMA), autoregressive integrated moving average (ARIMA) and artificial neural network (ANN). By comparing results of the above models, the validity of the proposed hybrid model is confirmed in terms of error and correlation coefficient. Comparison of results confirmed that the proposed method works effectively. Additional, forecasting errors were also computed and compared, to improve understanding of how to depict highly variable WPP and the correlations between actual and predicted wind power.

  14. High-intensity research infrastructure at ELI Beamlines

    Science.gov (United States)

    Klimo, Ondrej

    2017-10-01

    The L4 laser (10 PW, 150 fs) at ELI Beamlines is expected to provide focused intensities approaching 1023 W /cm2 and thus herald a new era of research in ultra-high intensity laser matter interaction. This talk will describe the progress in enabling the associated technological infrastructure - including the laser system, beam transport, diagnostics and the experimental chamber. Synergistic experimental and theoretical programs are also developing tools for such research. The talk will also briefly describe these research areas like development of dedicated diagnostic equipment, efforts toward obtaining ultra-high intensities using tight-focusing and theoretical modeling toward future experiments where radiation reaction in the classical and quantum regime and pair production start to play an important role. Supported from European Regional Development Funds - projects High Field Initiative (CZ.02.1.01/0.0/0.0/15_003/0000449) and ELI - phase 2 (CZ.02.1.01/0.0/0.0/15_008/0000162).

  15. Genetic Characteristic of Dominant Ultra Short Stem and Wax Coating Absence for Winter Rye (Secale cereale L.

    Directory of Open Access Journals (Sweden)

    В. В. Скорик

    2010-10-01

    Full Text Available By means of directed hybridization and selection, a new donor of Winter Rye with combination of ultra short stem and absence of wax coating has been synthesized. Markings was offered for the first time for dominant genes of ultra short stem characteristic – HI-3HI-3, and for recessive genes of absence of wax coating characteristic – wcwc. Determination is made of genetic variability, coefficients of inheritance, phenotype and genotype correlation coefficients, on the basis of which a selection strategy by ten quantitative characteristics is proposed. Polypheny and cohesion effects were established. Under certain conception, strategy and tactic of improvement by breeding of Winter Rye characteristics, determination of genetic and statistic parameters between traits of parents and the offspring is required.

  16. Recent Advances and New Techniques in Visualization of Ultra-short Relativistic Electron Bunches

    Energy Technology Data Exchange (ETDEWEB)

    Xiang, Dao; /SLAC

    2012-06-05

    Ultrashort electron bunches with rms length of {approx} 1 femtosecond (fs) can be used to generate ultrashort x-ray pulses in FELs that may open up many new regimes in ultrafast sciences. It is also envisioned that ultrashort electron bunches may excite {approx}TeV/m wake fields for plasma wake field acceleration and high field physics studies. Recent success of using 20 pC electron beam to drive an x-ray FEL at LCLS has stimulated world-wide interests in using low charge beam (1 {approx} 20 pC) to generate ultrashort x-ray pulses (0.1 fs {approx} 10 fs) in FELs. Accurate measurement of the length (preferably the temporal profile) of the ultrashort electron bunch is essential for understanding the physics associated with the bunch compression and transportation. However, the shorter and shorter electron bunch greatly challenges the present beam diagnostic methods. In this paper we review the recent advances in the measurement of ultra-short electron bunches. We will focus on several techniques and their variants that provide the state-of-the-art temporal resolution. Methods to further improve the resolution of these techniques and the promise to break the 1 fs time barrier is discussed. We review recent advances in the measurement of ultrashort relativistic electron bunches. We will focus on several techniques and their variants that are capable of breaking the femtosecond time barrier in measurements of ultrashort bunches. Techniques for measuring beam longitudinal phase space as well as the x-ray pulse shape in an x-ray FEL are also discussed.

  17. High-Intensity Plasma Glass Melter

    Energy Technology Data Exchange (ETDEWEB)

    None

    2004-01-01

    Modular high-intensity plasma melter promises improved performance, reduced energy use, and lower emissions. The glass industry has used the same basic equipment for melting glass for the past 100 years.

  18. High Intensity Exercise in Multiple Sclerosis

    DEFF Research Database (Denmark)

    Wens, Inez; Dalgas, Ulrik; Vandenabeele, Frank

    2015-01-01

    exercise groups that performed 12 weeks of a high intensity interval (HITR, n = 12) or high intensity continuous cardiovascular training (HCTR, n = 11), both in combination with resistance training. M.vastus lateralis fiber cross sectional area (CSA) and proportion, knee-flexor/extensor strength, body......±5%) and lean tissue mass (+1.4±0.5%) only increased in HITR. Finally self-reported physical activity levels increased 73±19% and 86±27% in HCTR and HITR, respectively. Conclusion High intensity cardiovascular exercise combined with resistance training was safe, well tolerated and improved muscle contractile......Introduction Low-to-moderate intensity exercise improves muscle contractile properties and endurance capacity in multiple sclerosis (MS). The impact of high intensity exercise remains unknown. Methods Thirty-four MS patients were randomized into a sedentary control group (SED, n = 11) and 2...

  19. Short-pulse lasers for weather control

    Science.gov (United States)

    Wolf, J. P.

    2018-02-01

    Filamentation of ultra-short TW-class lasers recently opened new perspectives in atmospheric research. Laser filaments are self-sustained light structures of 0.1–1 mm in diameter, spanning over hundreds of meters in length, and producing a low density plasma (1015–1017 cm‑3) along their path. They stem from the dynamic balance between Kerr self-focusing and defocusing by the self-generated plasma and/or non-linear polarization saturation. While non-linearly propagating in air, these filamentary structures produce a coherent supercontinuum (from 230 nm to 4 µm, for a 800 nm laser wavelength) by self-phase modulation (SPM), which can be used for remote 3D-monitoring of atmospheric components by Lidar (Light Detection and Ranging). However, due to their high intensity (1013–1014 W cm‑2), they also modify the chemical composition of the air via photo-ionization and photo-dissociation of the molecules and aerosols present in the laser path. These unique properties were recently exploited for investigating the capability of modulating some key atmospheric processes, like lightning from thunderclouds, water vapor condensation, fog formation and dissipation, and light scattering (albedo) from high altitude clouds for radiative forcing management. Here we review recent spectacular advances in this context, achieved both in the laboratory and in the field, reveal their underlying mechanisms, and discuss the applicability of using these new non-linear photonic catalysts for real scale weather control.

  20. Short-pulse lasers for weather control.

    Science.gov (United States)

    Wolf, J P

    2018-02-01

    Filamentation of ultra-short TW-class lasers recently opened new perspectives in atmospheric research. Laser filaments are self-sustained light structures of 0.1-1 mm in diameter, spanning over hundreds of meters in length, and producing a low density plasma (1015-1017 cm-3) along their path. They stem from the dynamic balance between Kerr self-focusing and defocusing by the self-generated plasma and/or non-linear polarization saturation. While non-linearly propagating in air, these filamentary structures produce a coherent supercontinuum (from 230 nm to 4 µm, for a 800 nm laser wavelength) by self-phase modulation (SPM), which can be used for remote 3D-monitoring of atmospheric components by Lidar (Light Detection and Ranging). However, due to their high intensity (1013-1014 W cm-2), they also modify the chemical composition of the air via photo-ionization and photo-dissociation of the molecules and aerosols present in the laser path. These unique properties were recently exploited for investigating the capability of modulating some key atmospheric processes, like lightning from thunderclouds, water vapor condensation, fog formation and dissipation, and light scattering (albedo) from high altitude clouds for radiative forcing management. Here we review recent spectacular advances in this context, achieved both in the laboratory and in the field, reveal their underlying mechanisms, and discuss the applicability of using these new non-linear photonic catalysts for real scale weather control.

  1. NATO Advanced Study Institute on Laser Interactions with Atoms, Solids,and Plasmas

    CERN Document Server

    1994-01-01

    The aim of this NATO Advanced Study Institute was to bring together scientists and students working in the field of laser matter interactions in order to review and stimulate developmentoffundamental science with ultra-short pulse lasers. New techniques of pulse compression and colliding-pulse mode-locking have made possible the construction of lasers with pulse lengths in the femtosecond range. Such lasers are now in operation at several research laboratories in Europe and the United States. These laser facilities present a new and exciting research direction with both pure and applied science components. In this ASI the emphasis is on fundamental processes occurring in the interaction of short laser pulses with atoms, molecules, solids, and plasmas. In the case of laser-atom (molecule) interactions, high power lasers provide the first access to extreme high-intensity conditions above 10'8 Watts/em', a new frontier for nonlinear interaction of photons with atoms and molecules. New phenomena observed include ...

  2. Fiscal 1998 R and D report on femtosecond technology (power generation facility monitoring system using high- intensity X-ray pulse); 1998 nendo femuto byo technology no kenkyu kaihatsu (kokido X senb pulse riyo hatsuden shisetsu monitoring system no kenkyu kaihatsu) seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    This report reports the fiscal 1998 R and D result of Femtosecond Technology Research Association (FESTA) supported by NEDO. For creation of industrial basic technologies supporting the advanced information society in the 21st century, ultra-high speed electronics technology including new functions beyond the speed limit of conventional electronics technologies is indispensable. From such viewpoint, this R and D aims at establishment of the basic technology controlling conditions of beams and electrons in a femtosecond (10{sup -15}-10{sup -12} seconds) region. In development of the titled system, this R and D aims at generation of high-intensity X-ray pulse by interaction between femtosecond light pulse and high-density electron beam pulse, and development of measurement technology (non- stop inspection) of high-speed moving objects using such X- ray pulse. In fiscal 1998, this project succeeded in time stabilization of laser oscillators at a 100fs level and generation of low-emittance electron beam pulse through development of ultra-short pulse synchronization, laser stabilization and electron beam pulse generation technologies. (NEDO)

  3. Short-pulse, high-energy radiation generation from laser-wakefield accelerated electron beams

    Science.gov (United States)

    Schumaker, Will

    2013-10-01

    Recent experimental results of laser wakefield acceleration (LWFA) of ~GeV electrons driven by the 200TW HERCULES and the 400TW ASTRA-GEMINI laser systems and their subsequent generation of photons, positrons, and neutrons are presented. In LWFA, high-intensity (I >1019 W /cm2), ultra-short (τL counter-propagating, ultra-high intensity (I >1021 W /cm2) laser pulse to undergo inverse Compton scattering and emit a high-peak brightness beam of high-energy photons. Preliminary results and experimental sensitivities of the electron-laser beam overlap are presented. The high-energy photon beams can be spectrally resolved using a forward Compton scattering spectrometer. Moreover, the photon flux can be characterized by a pixelated scintillator array and by nuclear activation and (γ,n) neutron measurements from the photons interacting with a secondary solid target. Monte-Carlo simulations were performed using FLUKA to support the yield estimates. This research was supported by DOE/NSF-PHY 0810979, NSF CAREER 1054164, DARPA AXiS N66001-11-1-4208, SF/DNDO F021166, and the Leverhulme Trust ECF-2011-383.

  4. Final Report on Institutional Computing Project s15_hilaserion, “Kinetic Modeling of Next-Generation High-Energy, High-Intensity Laser-Ion Accelerators as an Enabling Capability”

    Energy Technology Data Exchange (ETDEWEB)

    Albright, Brian James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Yin, Lin [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stark, David James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-06

    This proposal sought of order 1M core-hours of Institutional Computing time intended to enable computing by a new LANL Postdoc (David Stark) working under LDRD ER project 20160472ER (PI: Lin Yin) on laser-ion acceleration. The project was “off-cycle,” initiating in June of 2016 with a postdoc hire.

  5. Time-resolved microscopy using variable probe wavelengths for ultra-short pulse interaction (Conference Presentation)

    Science.gov (United States)

    Bergner, Klaus; Kumkar, Malte; Tünnermann, Andreas; Nolte, Stefan; Seyfarth, Brian

    2017-03-01

    Glass processing with ultrashort laser pulses allow for different material modifications, ranging from smooth refractive index changes which can be used for the generation of waveguides up to large disruptions due to accumulates stress for glass separation. These disruptions, generated by a dense electron plasma, are favored for glass dicing applications. To tailor the resulting material response a fundamental understanding of the laser/material interaction is of interest. Therefore, we analyze the spatio-temporal evolution of free carriers induced by ultrashort laser pulses using a pump-probe setup with high temporal and spatial resolution and various probe wavelengths. Single laser pulses with 1026nm wavelength, 6ps (FWHM) pulse duration and 200μJ pulse energy were applied to fused silica, Borofloat 33 and Gorilla glass. Electron densities around 1 x 1020cm-3 in the focal plane and 1 x 1019cm-3 in front of the focus are obtained, independent from the glass type used. The free carriers slowly decay within several ns, while the decay time depends on both the maximum electron densities reached and glass species. In this process a part of the excited electrons relax within several 10ps into a long-living stage where a transient effect is observed. Here, various probe wavelengths show differences in the recorded signal. A further carrier relaxation leads to permanent (stress, voids) and non-stable (color center) modifications crucial for precise glass dicing applications.

  6. Compression of ultra-short light pulses using the graded refractive index one-dimensional photonic crystals

    Science.gov (United States)

    Shiri, R.; Bananej, A.; Safari, E.

    2016-09-01

    The one-dimensional photonic crystals (1D PCs) containing a graded refractive index layer have been theoretically utilized to compress the positively chirped ultra-short pulses of light. Two types of simple and graded index multi-layer structures consisting alternating layers of TiO2 and SiO2 with the same total thicknesses and periodicity have been investigated and compared. For the graded structure, three different refractive index distributions including linear, exponential and parabolic profiles have been considered. The results revealed that replacing one of the homogeneous layers of the unit cells in simple photonic crystal with a graded material having parabolic refractive index profile efficiently improves compression behavior of the structure. The compress factors of as much as 47% and 78% depending on the pulse's initial chirp rate obtained with parabolic profile of such the structures.

  7. Deep ECGNet: An Optimal Deep Learning Framework for Monitoring Mental Stress Using Ultra Short-Term ECG Signals.

    Science.gov (United States)

    Hwang, Bosun; You, Jiwoo; Vaessen, Thomas; Myin-Germeys, Inez; Park, Cheolsoo; Zhang, Byoung-Tak

    2018-02-08

    Stress recognition using electrocardiogram (ECG) signals requires the intractable long-term heart rate variability (HRV) parameter extraction process. This study proposes a novel deep learning framework to recognize the stressful states, the Deep ECGNet, using ultra short-term raw ECG signals without any feature engineering methods. The Deep ECGNet was developed through various experiments and analysis of ECG waveforms. We proposed the optimal recurrent and convolutional neural networks architecture, and also the optimal convolution filter length (related to the P, Q, R, S, and T wave durations of ECG) and pooling length (related to the heart beat period) based on the optimization experiments and analysis on the waveform characteristics of ECG signals. The experiments were also conducted with conventional methods using HRV parameters and frequency features as a benchmark test. The data used in this study were obtained from Kwangwoon University in Korea (13 subjects, Case 1) and KU Leuven University in Belgium (9 subjects, Case 2). Experiments were designed according to various experimental protocols to elicit stressful conditions. The proposed framework to recognize stress conditions, the Deep ECGNet, outperformed the conventional approaches with the highest accuracy of 87.39% for Case 1 and 73.96% for Case 2, respectively, that is, 16.22% and 10.98% improvements compared with those of the conventional HRV method. We proposed an optimal deep learning architecture and its parameters for stress recognition, and the theoretical consideration on how to design the deep learning structure based on the periodic patterns of the raw ECG data. Experimental results in this study have proved that the proposed deep learning model, the Deep ECGNet, is an optimal structure to recognize the stress conditions using ultra short-term ECG data.

  8. Ion Beam Analysis applied to laser-generated plasmas

    Science.gov (United States)

    Cutroneo, M.; Macková, A.; Havranek, V.; Malinsky, P.; Torrisi, L.; Kormunda, M.; Barchuk, M.; Ullschmied, J.; Dudzak, R.

    2016-04-01

    This paper presents the research activity on Ion Beam Analysis methods performed at Tandetron Laboratory (LT) of the Institute of Nuclear Physics AS CR, Rez, Czech Republic. Recently, many groups are paying attention to implantation by laser generated plasma. This process allows to insert a controllable amount of energetic ions into the surface layers of different materials modifying the physical and chemical properties of the surface material. Different substrates are implanted by accelerated ions from plasma through terawatt iodine laser, at nominal intensity of 1015 W/cm2, at the PALS Research Infrastructure AS CR, in the Czech Republic. This regime of the laser matter interaction generates, multi-MeV proton beams, and multi-charged ions that are tightly confined in time (hundreds ps) and space (source radius of a few microns). These ion beams have a much lower transverse temperature, a much shorter duration and a much higher current than those obtainable from conventional accelerators. The implementation of protons and ions acceleration driven by ultra-short high intensity lasers is exhibited by adopting suitable irradiation conditions as well as tailored targets. An overview of implanted targets and their morphological and structural characterizations is presented and discussed.

  9. Interferometric laser detection of nanomechanical perturbations in biological media under ablation conditions

    Energy Technology Data Exchange (ETDEWEB)

    Morales-Bonilla, S; Torres-Torres, C; Urriolagoitia-Sosa, G; Hernandez-Gomez, L H; Urriolagoitia-Calderon, G, E-mail: crstorres@yahoo.com.mx [Instituto Politecnico Nacional Seccion de Estudios de Posgrado e Investigacion Escuela Superior de Ingenieria Mecanica y Electrica Unidad Profesional Adolfo Lopez Mateos ' Zacatenco' Col. Lindavista, CP 07738, Mexico, D. F. (Mexico)

    2011-07-19

    This article has to do with the development of a reliable and sensitive non-invasive laser technique for assessing damage of structures and systems involved in laser ablation processes. The optical response of a Michelson Interferometer in combination with a Measuring Reflectance System has been analyzed in order to identify the stability of the mechanical properties of the sample, the physical perturbations associated with the systems and the environment where the target is contained. This test includes the use of a cyan laser system with 10 mW at 488 nm wavelength as optical source. We found out that with the inclusion of an optical feedback in a sensing system it is possible to determine the modification of the physical properties exhibited by a biological medium under sharp ablation conditions with a high accuracy degree. The results reported in this research have potential applications related to the amount of light intensity that can be tolerated by human tissue. A wide array of disciplines, such as medicine, mechanical industry and optical instrumentation can benefit from this ultrafast optical feedback for controlling high intensity laser signals. Collateral damage of tissue around the laser irradiated zones can be reduced by using intelligent lasers systems with ultra-short temporal response.

  10. Dynamics of ultra-short electromagnetic pulses in the system of chiral carbon nanotube waveguides in the presence of external alternating electric field

    Energy Technology Data Exchange (ETDEWEB)

    Konobeeva, N.N., E-mail: yana_nn@inbox.ru [Volgograd State University, University Avenue 100, Volgograd 400062 (Russian Federation); Belonenko, M.B. [Volgograd Institute of Business, Uzhno-ukrainskaya str., Volgograd 400048 (Russian Federation)

    2014-04-01

    The paper addresses the propagation of ultra-short optical pulses in chiral carbon nanotubes in the presence of external alternating electric field. Following the assumption that the considered optical pulses are represented in the form of discrete solitons, we analyze the wave equation for the electromagnetic field and consider the dynamics of pulses in external field, their initial amplitudes and frequencies.

  11. Advanced modeling of high intensity accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Ryne, R.D.; Habib, S.; Wangler, T.P.

    1998-11-01

    This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The goals of this project were three-fold: (1) to develop a new capability, based on high performance (parallel) computers, to perform large scale simulations of high intensity accelerators; (2) to apply this capability to modeling high intensity accelerators under design at LANL; and (3) to use this new capability to improve the understanding of the physics of intense charge particle beams, especially in regard to the issue of beam halo formation. All of these goals were met. In particular, the authors introduced split-operator methods as a powerful and efficient means to simulate intense beams in the presence of rapidly varying accelerating and focusing fields. They then applied these methods to develop scaleable, parallel beam dynamics codes for modeling intense beams in linacs, and in the process they implemented a new three-dimensional space charge algorithm. They also used the codes to study a number of beam dynamics issues related to the Accelerator Production of Tritium (APT) project, and in the process performed the largest simulations to date for any accelerator design project. Finally, they used the new modeling capability to provide direction and validation to beam physics studies, helping to identify beam mismatch as a major source of halo formation in high intensity accelerators. This LDRD project ultimately benefited not only LANL but also the US accelerator community since, by promoting expertise in high performance computing and advancing the state-of-the-art in accelerator simulation, its accomplishments helped lead to approval of a new DOE Grand Challenge in Computational Accelerator Physics.

  12. End-tagging of ultra-short antimicrobial peptides by W/F stretches to facilitate bacterial killing.

    Directory of Open Access Journals (Sweden)

    Mukesh Pasupuleti

    Full Text Available BACKGROUND: Due to increasing resistance development among bacteria, antimicrobial peptides (AMPs, are receiving increased attention. Ideally, AMP should display high bactericidal potency, but low toxicity against (human eukaryotic cells. Additionally, short and proteolytically stable AMPs are desired to maximize bioavailability and therapeutic versatility. METHODOLOGY AND PRINCIPAL FINDINGS: A facile approach is demonstrated for reaching high potency of ultra-short antimicrobal peptides through end-tagging with W and F stretches. Focusing on a peptide derived from kininogen, KNKGKKNGKH (KNK10 and truncations thereof, end-tagging resulted in enhanced bactericidal effect against Gram-negative Escherichia coli and Gram-positive Staphylococcus aureus. Through end-tagging, potency and salt resistance could be maintained down to 4-7 amino acids in the hydrophilic template peptide. Although tagging resulted in increased eukaryotic cell permeabilization at low ionic strength, the latter was insignificant at physiological ionic strength and in the presence of serum. Quantitatively, the most potent peptides investigated displayed bactericidal effects comparable to, or in excess of, that of the benchmark antimicrobial peptide LL-37. The higher bactericidal potency of the tagged peptides correlated to a higher degree of binding to bacteria, and resulting bacterial wall rupture. Analogously, tagging enhanced peptide-induced rupture of liposomes, particularly anionic ones. Additionally, end-tagging facilitated binding to bacterial lipopolysaccharide, both effects probably contributing to the selectivity displayed by these peptides between bacteria and eukaryotic cells. Importantly, W-tagging resulted in peptides with maintained stability against proteolytic degradation by human leukocyte elastase, as well as staphylococcal aureolysin and V8 proteinase. The biological relevance of these findings was demonstrated ex vivo for pig skin infected by S. aureus and

  13. Linear Electro Optic Effect for High Repetition Rate Carrier Envelope Phase Control of Ultra Short Laser Pulses

    Directory of Open Access Journals (Sweden)

    Michel Comte

    2013-02-01

    Full Text Available This paper is devoted to analyzing the principle and applications of the linear electro-optic (EO effect for the control of the carrier-envelope-phase (CEP. We introduce and detail here an original method, which relies on the use of an EO dispersive prism pair in a compressor-like configuration. We show that, by choosing an adequate geometry, it is possible to shift the CEP without changing the group delay (isochronous carrier-envelope-phase shifter or change the induced group delay without varying the CEP. According to our calculations, when applying an electric field around 400 V/cm to the rubidium titanyle phosphate (RTP prisms in a double pass configuration (2 × 40 mm total length, one obtains a CEP shift of π rad at 800 nm without inducing a group delay. In contrast, this CEP shift is obtained for an electric field around 1.4 kV/cm in a RTP rectangular slab of the same total length and, in this case, the group delay is of the order of a few fs.

  14. Simultaneous determination of three antioxidants in foods and cosmetics by flow injection coupled to an ultra-short monolithic column.

    Science.gov (United States)

    García-Jiménez, J F; Valencia, M C; Capitán-Vallvey, L F

    2009-07-01

    The combination of an ultra-short C18 monolithic column (5 mm long) with flow injection analysis results in a versatile and efficient system that has been used for the determination of three antioxidants [propylgallate (PG), butylhydroxyanisole (BA), and butylhydroxytoluene (BT)]. Due to the wide variety of polarities of the analytes, two different carriers (carrier A: methanol-water 42% and carrier B: methanol-water 70%) were able to separate the analytes in only 85 s. The applicable concentration range, the detection, and the relative standard deviation (n=10) were: for PG, from 2.77 to 300 microg/mL, 0.84 microg/mL, 2.84%; for BA, between 1.51 and 300 microg/mL, 0.46 microg/mL, and 2.70%; and for BT, between 1.65 and 100 microg/mL, 0.55 microg/mL, and 2.22%, respectively. The method was applied and validated satisfactorily for the determination of PG, BA, and BT in food and cosmetic samples.

  15. The Discovery and Mass Measurement of a New Ultra-short-period Planet: K2-131b

    Science.gov (United States)

    Dai, Fei; Winn, Joshua N.; Gandolfi, Davide; Wang, Sharon X.; Teske, Johanna K.; Burt, Jennifer; Albrecht, Simon; Barragán, Oscar; Cochran, William D.; Endl, Michael; Fridlund, Malcolm; Hatzes, Artie P.; Hirano, Teruyuki; Hirsch, Lea A.; Johnson, Marshall C.; Justesen, Anders Bo; Livingston, John; Persson, Carina M.; Prieto-Arranz, Jorge; Vanderburg, Andrew; Alonso, Roi; Antoniciello, Giuliano; Arriagada, Pamela; Butler, R. P.; Cabrera, Juan; Crane, Jeffrey D.; Cusano, Felice; Csizmadia, Szilárd; Deeg, Hans; Dieterich, Sergio B.; Eigmüller, Philipp; Erikson, Anders; Everett, Mark E.; Fukui, Akihiko; Grziwa, Sascha; Guenther, Eike W.; Henry, Gregory W.; Howell, Steve B.; Johnson, John Asher; Korth, Judith; Kuzuhara, Masayuki; Narita, Norio; Nespral, David; Nowak, Grzegorz; Palle, Enric; Pätzold, Martin; Rauer, Heike; Montañés Rodríguez, Pilar; Shectman, Stephen A.; Smith, Alexis M. S.; Thompson, Ian B.; Van Eylen, Vincent; Williamson, Michael W.; Wittenmyer, Robert A.

    2017-12-01

    We report the discovery of a new ultra-short-period planet and summarize the properties of all such planets for which the mass and radius have been measured. The new planet, K2-131b, was discovered in K2 Campaign 10. It has a radius of {1.81}-0.12+0.16 {R}\\oplus and orbits a G dwarf with a period of 8.9 hr. Radial velocities obtained with Magellan/PFS and TNG/HARPS-N show evidence for stellar activity along with orbital motion. We determined the planetary mass using two different methods: (1) the “floating chunk offset” method, based only on changes in velocity observed on the same night; and (2) a Gaussian process regression based on both the radial velocity and photometric time series. The results are consistent and lead to a mass measurement of 6.5+/- 1.6 {M}\\oplus and a mean density of {6.0}-2.7+3.0 g cm-3.

  16. High-intensity, focused ultrasonic fields

    DEFF Research Database (Denmark)

    Jensen, Leif Bjørnø

    1988-01-01

    The use of extracorporeal shock wave lithotripsy (ESWL) for disintegration of body stones has increased considerably during recent years. A worldwide activity in this field is reflected in a growing number of international publications and in the development and manufacturing of several ESWL...... machines marketed by companies in Germany and France, in particular. Two main types of ESWL systems are prevailing, the spark gap-based and the piezoelectric disk-based systems. This paper is introduced by a brief reconsideration of the features of pressure waves in water produced by an electrical...... distribution, etc. involving nonlinearity, diffraction, and absorption in the high-intensity focused ultrasonic fields produced by an ellipsoid as well as a spherical cap focusing geometry. Data from the development of an ESWL of the piezoelectric disk type are reported including demands to transducers...

  17. Production of high intensity radioactive beams

    Energy Technology Data Exchange (ETDEWEB)

    Nitschke, J.M.

    1990-04-01

    The production of radioactive nuclear beams world-wide is reviewed. The projectile fragmentation and the ISOL approaches are discussed in detail, and the luminosity parameter is used throughout to compare different production methods. In the ISOL approach a thin and a thick target option are distinguished. The role of storage rings in radioactive beam research is evaluated. It is concluded that radioactive beams produced by the projectile fragmentation and the ISOL methods have complementary characteristics and can serve to answer different scientific questions. The decision which kind of facility to build has to depend on the significance and breadth of these questions. Finally a facility for producing a high intensity radioactive beams near the Coulomb barrier is proposed, with an expected luminosity of {approximately}10{sup 39} cm{sup {minus}2} s{sup {minus}1}, which would yield radioactive beams in excess of 10{sup 11} s{sup {minus}1}. 9 refs., 3 figs., 7 tabs.

  18. Femto- and pico second laser micro-nano processing for patterning surfaces by removal and deposition of materials

    NARCIS (Netherlands)

    Huis in 't veld, A.J.

    2011-01-01

    Ultra short laser pulses in the femto and pico second regime are the most important driver of new laser processes. 3D - Laser micro machining in a direct write mode is already available on an industrial scale whereas in the coming years laser nano machining will be further developed. The key for

  19. An ultra-short screening version of the Recalled Parental Rearing Behavior questionnaire (FEE-US and its factor structure in a representative German sample

    Directory of Open Access Journals (Sweden)

    Petrowski Katja

    2012-11-01

    Full Text Available Abstract Background The Recalled Parental Rearing Behavior questionnaire (FEE, [1,2] assesses perceived parental rearing behavior separately for each parent. An ultra-short screening version (FEE-US with the same three scales each for the mother and the father is reported and factor-analytically validated. Methods N = 4,640 subjects aged 14 to 92 (M = 48.4 years were selected by the random-route sampling method. The ultra-short questionnaire version was derived from the long version through item and factor analyses. In a confirmatory factor analysis framework, the hypothesized three-factorial structure was fitted to the empirical data and tested for measurement invariance, differential item functioning, item discriminability, and convergent and discriminant factorial validity. Effects of gender or age were assessed using MANOVAs. Results The a-priori hypothesized model resulted in mostly adequate overall fit. Neither gender nor age group yielded considerable effects on the factor structure, but had small effects on means of raw score sums. Factorial validities could be confirmed. Scale sums are well-suited to rank respondents along the respective latent dimension. Conclusion The structure of the long version with the factors Rejection & Punishment, Emotional Warmth, and Control & Overprotection could be replicated for both father and mother items in the ultra-short screening version using confirmatory factor analyses. These results indicate that the ultra-short screening version is a time-saving and promising screening instrument for research settings and in individual counseling. However, the shortened scales do not necessarily represent the full spectrum covered by the full-scale dimensions.

  20. High-Power, High-Intensity Laser Propagation and Interactions

    Science.gov (United States)

    2014-03-10

    T.M. Antonsen, O.V. Sinitsyn, J.Rodgers, A.Mohamed, J. Silverman , M.Al-Sheikhly, Y.S. Dimant, G.M. Milikh, M.Yu, Glyavin, A.G. Luchinin, E.A...Phys. of Plasmas, 21, 013103 (2014). 94. E.T. Gerry, Appl. Phys. Lett. 7, 6 (1965). 95. A.W. Ali, A.C. Kolb and A.D. Anderson , Appl. Opt. 6

  1. AGS RESONANT EXTRACTION WITH HIGH INTENSITY BEAMS.

    Energy Technology Data Exchange (ETDEWEB)

    AHRENS,L.; BROWN,K.; GLENN,J.W.; ROSER,T.; TSOUPAS,N.; VANASSELT,W.

    1999-03-29

    The Brookhaven AGS third integer resonant extraction system allows the AGS to provide high quality, high intensity 25.5 GeV/c proton beams simultaneously to four target stations and as many as 8 experiments. With the increasing intensities (over 7 x 10{sup 13} protons/pulse) and associated longer spill periods (2.4 to 3 seconds long), we continue to run with low losses and high quality low modulation continuous current beams.[1] Learning to extract and transport these higher intensity beams has required a process of careful modeling and experimentation. We have had to learn how to correct for various instabilities and how to better match extraction and the transport lines to the higher emittance beams being accelerated in the AGS. Techniques employed include ''RF'' methods to smooth out momentum distributions and fine structure. We will present results of detailed multi-particle tracking modeling studies which enabled us to develop a clear understanding of beam loss mechanisms in the transport and extraction process. We will report on our status, experiences, and the present understanding of the intensity limitations imposed by resonant extraction and transport to fixed target stations.

  2. High-Intensity Sweeteners and Energy Balance

    Science.gov (United States)

    Swithers, Susan E.; Martin, Ashley A.; Davidson, Terry L.

    2010-01-01

    Recent epidemiological evidence points to a link between a variety of negative health outcomes (e.g. metabolic syndrome, diabetes and cardiovascular disease) and the consumption of both calorically sweetened beverages and beverages sweetened with high-intensity, non-caloric sweeteners. Research on the possibility that non-nutritive sweeteners promote food intake, body weight gain, and metabolic disorders has been hindered by the lack of a physiologically-relevant model that describes the mechanistic basis for these outcomes. We have suggested that based on Pavlovian conditioning principles, consumption of non-nutritive sweeteners could result in sweet tastes no longer serving as consistent predictors of nutritive postingestive consequences. This dissociation between the sweet taste cues and the caloric consequences could lead to a decrease in the ability of sweet tastes to evoke physiological responses that serve to regulate energy balance. Using a rodent model, we have found that intake of foods or fluids containing non-nutritive sweeteners was accompanied by increased food intake, body weight gain, accumulation of body fat, and weaker caloric compensation, compared to consumption of foods and fluids containing glucose. Our research also provided evidence consistent with the hypothesis that these effects of consuming saccharin may be associated with a decrement in the ability of sweet taste to evoke thermic responses, and perhaps other physiological, cephalic phase, reflexes that are thought to help maintain energy balance. PMID:20060008

  3. High intensity neutrino oscillation facilities in Europe

    CERN Document Server

    Edgecock, T.R.; Davenne, T.; Densham, C.; Fitton, M.; Kelliher, D.; Loveridge, P.; Machida, S.; Prior, C.; Rogers, C.; Rooney, M.; Thomason, J.; Wilcox, D.; Wildner, E.; Efthymiopoulos, I.; Garoby, R.; Gilardoni, S.; Hansen, C.; Benedetto, E.; Jensen, E.; Kosmicki, A.; Martini, M.; Osborne, J.; Prior, G.; Stora, T.; Melo-Mendonca, T.; Vlachoudis, V.; Waaijer, C.; Cupial, P.; Chancé, A.; Longhin, A.; Payet, J.; Zito, M.; Baussan, E.; Bobeth, C.; Bouquerel, E.; Dracos, M.; Gaudiot, G.; Lepers, B.; Osswald, F.; Poussot, P.; Vassilopoulos, N.; Wurtz, J.; Zeter, V.; Bielski, J.; Kozien, M.; Lacny, L.; Skoczen, B.; Szybinski, B.; Ustrzycka, A.; Wroblewski, A.; Marie-Jeanne, M.; Balint, P.; Fourel, C.; Giraud, J.; Jacob, J.; Lamy, T.; Latrasse, L.; Sortais, P.; Thuillier, T.; Mitrofanov, S.; Loiselet, M.; Keutgen, Th.; Delbar, Th.; Debray, F.; Trophine, C.; Veys, S.; Daversin, C.; Zorin, V.; Izotov, I.; Skalyga, V.; Burt, G.; Dexter, A.C.; Kravchuk, V.L.; Marchi, T.; Cinausero, M.; Gramegna, F.; De Angelis, G.; Prete, G.; Collazuol, G.; Laveder, M.; Mazzocco, M.; Mezzetto, M.; Signorini, C.; Vardaci, E.; Di Nitto, A.; Brondi, A.; La Rana, G.; Migliozzi, P.; Moro, R.; Palladino, V.; Gelli, N.; Berkovits, D.; Hass, M.; Hirsh, T.Y.; Schaumann, M.; Stahl, A.; Wehner, J.; Bross, A.; Kopp, J.; Neuffer, D.; Wands, R.; Bayes, R.; Laing, A.; Soler, P.; Agarwalla, S.K.; Cervera Villanueva, A.; Donini, A.; Ghosh, T.; Gómez Cadenas, J.J.; Hernández, P.; Martín-Albo, J.; Mena, O.; Burguet-Castell, J.; Agostino, L.; Buizza-Avanzini, M.; Marafini, M.; Patzak, T.; Tonazzo, A.; Duchesneau, D.; Mosca, L.; Bogomilov, M.; Karadzhov, Y.; Matev, R.; Tsenov, R.; Akhmedov, E.; Blennow, M.; Lindner, M.; Schwetz, T.; Fernández Martinez, E.; Maltoni, M.; Menéndez, J.; Giunti, C.; González García, M. C.; Salvado, J.; Coloma, P.; Huber, P.; Li, T.; López-Pavón, J.; Orme, C.; Pascoli, S.; Meloni, D.; Tang, J.; Winter, W.; Ohlsson, T.; Zhang, H.; Scotto-Lavina, L.; Terranova, F.; Bonesini, M.; Tortora, L.; Alekou, A.; Aslaninejad, M.; Bontoiu, C.; Kurup, A.; Jenner, L.J.; Long, K.; Pasternak, J.; Pozimski, J.; Back, J.J.; Harrison, P.; Beard, K.; Bogacz, A.; Berg, J.S.; Stratakis, D.; Witte, H.; Snopok, P.; Bliss, N.; Cordwell, M.; Moss, A.; Pattalwar, S.; Apollonio, M.

    2013-02-20

    The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fr\\'ejus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of {\\mu}+ and {\\mu}- beams in a storage ring. The far detector in this case is a 100 kt Magnetised Iron Neutrino Detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular 6He and 18Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fr\\'ejus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the ph...

  4. High intensity neutrino oscillation facilities in Europe

    Directory of Open Access Journals (Sweden)

    T. R. Edgecock

    2013-02-01

    Full Text Available The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fréjus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of μ^{+} and μ^{-} beams in a storage ring. The far detector in this case is a 100 kt magnetized iron neutrino detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular ^{6}He and ^{18}Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fréjus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the physics reach of each facility, in particular for the measurement of CP violation in the lepton sector, and estimated the cost of construction. These have demonstrated that the best facility to build is the Neutrino Factory. However, if a powerful proton driver is constructed for another purpose or if the MEMPHYS detector is built for astroparticle physics, the Super Beam also becomes very attractive.

  5. Laser Drilling Development Trial Final Report CRADA No. TSB-1538-98

    Energy Technology Data Exchange (ETDEWEB)

    Hermann, M. R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hebbar, R. R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-11-01

    This project performed various laser drilling tests to demonstrate femtosecond laser drilling of fuel injector nozzles with minimal recast, minimal heat affected zone and no collateral damage. LLNL had extensive experience in ultra short-pulse laser systems and developed specialized hardware for these applications.

  6. Focussing effects in laser-electron Thomson scattering

    CERN Document Server

    Harvey, C; Holkundkar, A R

    2016-01-01

    We study the effects of laser pulse focussing on the spectral properties of Thomson scattered radiation. Modelling the laser as a paraxial beam we find that, in all but the most extreme cases of focussing, the temporal envelope has a much bigger effect on the spectrum than the focussing itself. For the case of ultra-short pulses where the paraxial model is no longer valid, we adopt a sub-cycle vector beam description of the field. It is found that the emission harmonics are blue shifted and broaden out in frequency space as the pulse becomes shorter. Additionally the carrier envelope phase becomes important, resulting in an angular asymmetry in the spectrum. We then use the same model to study the effects of focussing beyond the limit where the paraxial expansion is valid. It is found that fields focussed to sub-wavelength spot sizes produce spectra that are qualitatively similar to those from sub-cycle pulses due to the shortening of the pulse with focussing. Finally, we study high-intensity fields and find ...

  7. A voxel-based investigation for MRI-only radiotherapy of the brain using ultra short echo times

    Science.gov (United States)

    Edmund, Jens M.; Kjer, Hans M.; Van Leemput, Koen; Hansen, Rasmus H.; Andersen, Jon AL; Andreasen, Daniel

    2014-12-01

    Radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, so-called MRI-only RT, would remove the systematic registration error between MR and computed tomography (CT), and provide co-registered MRI for assessment of treatment response and adaptive RT. Electron densities, however, need to be assigned to the MRI images for dose calculation and patient setup based on digitally reconstructed radiographs (DRRs). Here, we investigate the geometric and dosimetric performance for a number of popular voxel-based methods to generate a so-called pseudo CT (pCT). Five patients receiving cranial irradiation, each containing a co-registered MRI and CT scan, were included. An ultra short echo time MRI sequence for bone visualization was used. Six methods were investigated for three popular types of voxel-based approaches; (1) threshold-based segmentation, (2) Bayesian segmentation and (3) statistical regression. Each approach contained two methods. Approach 1 used bulk density assignment of MRI voxels into air, soft tissue and bone based on logical masks and the transverse relaxation time T2 of the bone. Approach 2 used similar bulk density assignments with Bayesian statistics including or excluding additional spatial information. Approach 3 used a statistical regression correlating MRI voxels with their corresponding CT voxels. A similar photon and proton treatment plan was generated for a target positioned between the nasal cavity and the brainstem for all patients. The CT agreement with the pCT of each method was quantified and compared with the other methods geometrically and dosimetrically using both a number of reported metrics and introducing some novel metrics. The best geometrical agreement with CT was obtained with the statistical regression methods which performed significantly better than the threshold and Bayesian segmentation methods (excluding spatial information). All methods agreed significantly better with CT than a reference water MRI

  8. Evidence based exercise: Clinical benefits of high intensity interval training

    National Research Council Canada - National Science Library

    Shiraev, Tim; Barclay, Gabriella

    2012-01-01

    ...: This article describes the benefits of exercise for patients with cardiovascular and metabolic disease and details the numerous benefits of high intensity interval training (HIIT) in particular. Discussion...

  9. Review of High-intensity Interval Training in Cardiac Rehabilitation

    National Research Council Canada - National Science Library

    Ito, Shigenori; Mizoguchi, Tatsuya; Saeki, Tomoaki

    2016-01-01

    .... Although moderate-intensity continuous training has been the main training regimen recommended in cardiac rehabilitation guidelines, high-intensity interval training has been reported to be more...

  10. Ultrashort Laser Pulse Phenomena

    CERN Document Server

    Diels, Jean-Claude

    2006-01-01

    Ultrashort Laser Pulse Phenomena, 2e serves as an introduction to the phenomena of ultra short laser pulses and describes how this technology can be used to examine problems in areas such as electromagnetism, optics, and quantum mechanics. Ultrashort Laser Pulse Phenomena combines theoretical backgrounds and experimental techniques and will serve as a manual on designing and constructing femtosecond (""faster than electronics"") systems or experiments from scratch. Beyond the simple optical system, the various sources of ultrashort pulses are presented, again with emphasis on the basic

  11. Testing relativity again, laser, laser, laser, laser

    NARCIS (Netherlands)

    Einstein, A.

    2015-01-01

    laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser,

  12. ELECTRON CLOUD EFFECTS IN HIGH INTENSITY PROTON ACCELERATORS.

    Energy Technology Data Exchange (ETDEWEB)

    WEI,J.; MACEK,R.J.

    2002-04-14

    One of the primary concerns in the design and operation of high-intensity proton synchrotrons and accumulators is the electron cloud and associated beam loss and instabilities. Electron-cloud effects are observed at high-intensity proton machines like the Los Alamos National Laboratory's PSR and CERN's SPS, and investigated experimentally and theoretically. In the design of next-generation high-intensity proton accelerators like the Spallation Neutron Source ring, emphasis is made in minimizing electron production and in enhancing Landau damping. This paper reviews the present understanding of the electron-cloud effects and presents mitigation measures.

  13. Picosecond X-ray diffraction from laser-irradiated crystals

    Energy Technology Data Exchange (ETDEWEB)

    Hironaka, Yoichiro; Yazaki, Akio; Kishimura, Hiroaki; Nakamura, Kazutaka G.; Kondo, Ken-ichi

    2002-09-30

    We performed time-resolved X-ray diffraction for laser-irradiated Si(1 1 1) single crystal. A tabletop TW laser system was used for the generation of the ultra-short pulsed X-rays. We discussed the generation of laser induced ultra-short pulsed X-rays concerning about broadening of diffracted signal due to the electron scattering in the pre-plasma. We measured laser induced acoustic wave propagation inside of Si crystal by the laser irradiation, and the maximum lattice strain of -1.05% was measured at the irradiation power density of 4.7x10{sup 9} W/cm{sup 2} with picosecond time resolution. Stress distribution analysis on the observed data under laser irradiation is also dised.

  14. Application of optical elements for temporal and spatial transformation of ultra-short and ultra-intense light pulses

    Science.gov (United States)

    Stanke, Ladislav; Křepelka, Jaromír.; Palatka, Miroslav; Schovánek, Petr; Hrabovský, Miroslav

    2012-01-01

    The goal of the ELI (Extreme Light Infrastructure) project is to build a laser centre with the worlds highest power output pulsed laser in the locality of Dolní Břežany near Prague. Presented paper offers first glance to the insight into continuous and pulsed beam interaction with various optical systems which causes beam's spatial and temporal transformation. Complexity of this problem is illustrated in need of geometrical and physical optics knowledge, numerical simulations, material engineering and many others. This paper is focused on the field trace simulations in various software environments for both simple and more complex optical systems.

  15. Efficacy of ultra-short single agent regimen antibiotic chemo-prophylaxis in reducing the risk of meningitis in patients undergoing endoscopic endonasal transsphenoidal surgery.

    Science.gov (United States)

    Somma, Teresa; Maraolo, Alberto Enrico; Esposito, Felice; Cavallo, Luigi Maria; Tosone, Grazia; Orlando, Raffaele; Cappabianca, Paolo

    2015-12-01

    The study aims to evaluate the incidence of infectious complications (namely meningitis) within 30 days after endoscopic endonasal transspheinodal neurosurgery (EETS) in patients receiving an ultra-short peri-operative chemo-prophylaxis regimen with 2 doses of 1st generation cephalosporin or macrolide. We retrospectively analyzed the clinical records of 145 patients who received an ultra-short chemoprophylaxis with two doses of an antibiotic, given 30 min before and 8h after EETS, over a 30-month time-frame. Ninety-seven patients (66.89%) received endovenous cefazolin, a 1st generation cephalosporin, administered at a dosage of 1000 mg, and 48 patients (33.10%) with an history of allergy to various agents, received endovenous clarithromycin at a dosage of 500 mg. No case of peri- and post-operative meningitis occurred in patients receiving the 2 doses of antibiotic. Only one patient (0.68%) developed cerebral fluid leakage on the 7th postoperative day, which required the switching to a broad-spectrum antibiotic prophylaxis for one week; this patient received the ultrashort prophylaxis with a macrolide. In addition, 7 patients (4.82%) developed minor infectious complications such as low-grade fever (3 cases, all of them receiving cefazolin), enlarged submandibular and cervical lymphnodes (3 cases, all of them receiving cefazolin), and upper and lower respiratory tract infection (1 case receiving clarithromycin). The cost of this prophylaxis regimen ranged from 7.76 Euro (cefazolin) to 39.54 Euro (clarithromycin). This study suggested that an ultra-short single-antibiotic prophylaxis is a safe, cheap and effective regimen to prevent post-operative meningitis in patients undergoing EETS and who do not require lumbar drainage after surgery. In these patients also the rate of minor infective complications was acceptable when compared with the previous more expensive regimen based on 3rd generation cephalosporin plus aminoglycoside or alone, that could be suitable only

  16. Concept for a new high resolution high intensity diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Stuhr, U. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A concept of a new time-of-flight powder-diffractometer for a thermal neutral beam tube at SINQ is presented. The design of the instrument optimises the contradictory conditions of high intensity and high resolution. The high intensity is achieved by using many neutron pulses simultaneously. By analysing the time-angle-pattern of the detected neutrons an assignment of the neutrons to a single pulse is possible. (author) 3 figs., tab., refs.

  17. Detection of laser-accelerated protons

    Energy Technology Data Exchange (ETDEWEB)

    Reinhardt, Sabine

    2012-08-08

    applicable for this purpose. Segmentation of the sensitive area into smaller, independent detection units (pixel) allows the measurement of a higher particle flux compared to an unsegmented sensor of the same size-a concept used at the LHC. Within this work, three pixel detectors of different architectures were investigated in extensive experiments with respect to their applicability for laser-accelerated proton detection. The detector response to ultra-short highly-intense proton pulses was studied at a conventional accelerator in view of linearity and saturation effects. All systems allow single proton detection. However, only two of the systems were able to detect a proton flux of up to 10{sup 7} p/cm{sup 2}/ns (20 MeV) without saturation. This was also confirmed at the ATLAS laser for the final selected system. No EMP sensitivity was observed there as well as at the ASTRA-GEMINI laser with up to 6 J pulse energy. The read-out electronic of the detector and a computer system were integrated into a stand-alone system, which was upgraded by an user-friendly software. Hence, a compact online detection system as well as a dosimetry protocol were made available, which fulfil the demands of the momentary state of affairs of the laser-ion-acceleration.

  18. Interaction dynamics of fs-laser induced cavitation bubbles and their impact on the laser-tissue-interaction of modern ophthalmic laser systems

    Science.gov (United States)

    Tinne, N.; Ripken, T.; Lubatschowski, H.; Heisterkamp, A.

    2011-07-01

    A today well-known laser based treatment in ophthalmology is the LASIK procedure which nowadays includes cutting of the corneal tissue with ultra-short laser pulses. Instead of disposing a microkeratome for cutting a corneal flap, a focused ultra-short laser pulse is scanned below the surface of biological tissue causing the effect of an optical breakdown and hence obtaining a dissection. Inside the tissue, the energy of the laser pulses is absorbed by non-linear processes; as a result a cavitation bubble expands and ruptures the tissue. Hence, positioning of several optical breakdowns side by side generates an incision. Due to a reduction of the amount of laser energy, with a moderate duration of treatment at the same time, the current development of ultra-short pulse laser systems points to higher repetition rates in the range of even Megahertz instead of tens or hundreds of Kilohertz. In turn, this results in a pulse overlap and therefor a probable occurrence of interaction between different optical breakdowns and respectively cavitation bubbles of adjacent optical breakdowns. While the interaction of one single laser pulse with biological tissue is analyzed reasonably well experimentally and theoretically, the interaction of several spatial and temporal following pulses is scarcely determined yet. Thus, the aim of this study is to analyse the dynamic and interaction of two cavitation bubbles by using high speed photography. The applied laser pulse energy, the energy ratio and the spot distance between different cavitation bubbles were varied. Depending on a change of these parameters different kinds of interactions such as a flattening and deformation of bubble shape or jet formation are observed. The effects will be discussed regarding the medical ophthalmic application of fs-lasers. Based on these results a further research seems to be inevitable to comprehend and optimize the cutting effect of ultra-short pulse laser systems with high (> 500 kHz) repetition

  19. Repeated high-intensity exercise in professional rugby union.

    Science.gov (United States)

    Austin, Damien; Gabbett, Tim; Jenkins, David

    2011-07-01

    The aim of the present study was to describe the frequency, duration, and nature of repeated high-intensity exercise in Super 14 rugby union. Time-motion analysis was used during seven competition matches over the 2008 and 2009 Super 14 seasons; five players from each of four positional groups (front row forwards, back row forwards, inside backs, and outside backs) were assessed (20 players in total). A repeated high-intensity exercise bout was considered to involve three or more sprints, and/or tackles and/or scrum/ruck/maul activities within 21 s during the same passage of play. The range of repeated high-intensity exercise bouts for each group in a match was as follows: 11-18 for front row forwards, 11-21 for back row forwards, 13-18 for inside backs, and 2-11 for outside backs. The durations of the most intense repeated high-intensity exercise bouts for each position ranged from 53 s to 165 s and the minimum recovery periods between repeated high-intensity exercise bouts ranged from 25 s for the back row forwards to 64 s for the front row forwards. The present results show that repeated high-intensity exercise bouts vary in duration and activities relative to position but all players in a game will average at least 10 changes in activity in the most demanding bouts and complete at least one tackle and two sprints. The most intense periods of activity are likely to last as long as 120 s and as little as 25 s recovery may separate consecutive repeated high-intensity exercise bouts. The present findings can be used by coaches to prepare their players for the most demanding passages of play likely to be experienced in elite rugby union.

  20. High-intensity aerobic interval exercise in chronic heart failure.

    Science.gov (United States)

    Meyer, Philippe; Gayda, Mathieu; Juneau, Martin; Nigam, Anil

    2013-06-01

    Aerobic exercise training is strongly recommended in patients with heart failure (HF) and reduced left ventricular ejection fraction (LVEF) to improve symptoms and quality of life. Moderate-intensity aerobic continuous exercise (MICE) is the best established training modality in HF patients. For about a decade, however, another training modality, high-intensity aerobic interval exercise (HIIE), has aroused considerable interest in cardiac rehabilitation. Originally used by athletes, HIIE consists of repeated bouts of high-intensity exercise interspersed with recovery periods. The rationale for its use is to increase exercise time spent in high-intensity zones, thereby increasing the training stimulus. Several studies have demonstrated that HIIE is more effective than MICE, notably for improving exercise capacity in patients with HF. The aim of the present review is to describe the general principles of HIIE prescription, the acute physiological effects, the longer-term training effects, and finally the future perspectives of HIIE in patients with HF.

  1. Novel D-shaped fiber fabrication method for saturable absorber application in the generation of ultra-short pulses

    Science.gov (United States)

    Ahmad, H.; Safaei, R.; Rezayi, M.; Amiri, I. S.

    2017-08-01

    A cost-efficient, time-saving and effective technique for the fabrication of D-shaped fibers is presented, to provide a platform with a strong evanescent field to be used as a saturable absorber (SA). This technique provides flexibility by removing the required portion of the fiber, and a small polished length which offers a unique opportunity to deposit SA on its surface by simply submerging it in the SA solution without high losses. A compact fiber laser utilizing a graphene oxide coating on a fabricated D-shaped fiber as an SA capable of generating ultrashort pulses is designed and verified. We report the generation of ultrafast pulses as short as 227 fs with a 34.7 MHz repetition rate, having a 3 dB bandwidth of 14 nm at the 1570 nm center wavelength.

  2. Relativistic Electron Acceleration by Surface Plasma Waves in the High Intensity Regime

    Science.gov (United States)

    Zhu, Xiaoming; Cerchez, Mirela; Swantusch, Marco; Aurand, Bastian; Prasad, Rajendra; Andreev, Alexander; Willi, Oswald

    2017-10-01

    High field plasmonics is one of the new research fields which has synergetically benefited from the advances in laser technology. The availability of radiation fields of intensities exceeding 1018 W/cm2 brought plasmonics into a new regime where relativistic and nonlinear effects start to dominate the dynamics of the surface plasma waves (SPWs). Moreover, surface plasma waves are a very efficient route to transfer the laser energy to the secondary sources including laser driven particle and radiation beams and to control and optimize the physical properties of these sources. We present here experimental evidence of a novel regime of the SPWs excitation by ultra-high intensity laser field (I>1020 W/cm2) on grating targets and its effect on high energy surface electron acceleration. The peak of the electron emission was detected at a laser incidence angle of 45°. The results indicate new conditions for resonant excitation of SPWs since in the limit of the linear regime (moderate intensities of 1019 W/cm2 and step preplasma profile), the resonance angle is predicted at 30°. 2D PIC simulations and a novel analytical model confirm the experimental data and reveal that, at laser intensities above 1020W/cm2, nonlinearities induced by the preplasma condition and relativistic effects change the SPWs resonance.

  3. Proton probing of ultra-thin foil dynamics in high intensity regime

    Science.gov (United States)

    Prasad, Rajendra; Aktan, Esin; Aurand, Bastian; Cerchez, Mirela; Willi, Oswald

    2017-10-01

    The field of laser driven ion acceleration has been enriched significantly over the past decade, thanks to the advanced laser technologies. Already, from 100s TW class systems, laser driven sources of particles and radiations are being considered in number of potential applications in science and medicine due to their unique properties. New physical effects unearthed at these systems may help understand and conduct successful experiments at several PW class multi-beam facilities with high rep rate systems, e.g. ELI. Here we present the first experimental results on ultra-thin foil dynamics irradiated by an ultra-high intensity (1020 W/cm2) , ultra-high contrast (10-12) laser pulse at ARCTURUS laser facility at HHU Duesseldorf. By employing the elegant proton probing technique it is observed that for the circular polarization of laser light, a 100nm thin target is pushed forward as a compressed layer due to the radiation pressure of light. Whereas, the linear polarization seems to decompress the target drastically. 2D particle-in-cell simulations corroborate the experimental findings. Our results confirm the previous simulation studies investigating the fundamental role played by light polarization, finite focus spot size effect and eventually electron heating including the oblique incidence at the target edges.

  4. Ablation of steel under surface irradiation by high-intensity tandem pulses

    Science.gov (United States)

    Kononenko, V. V.; Konov, V. I.

    2018-01-01

    Specific features of interaction of high-intensity (1015 W cm-2) femtosecond laser pulses with ablated vapour are experimentally studied under a tandem (double pulse) regime of irradiation with a short (Δt = 1–11 ns) delay between the pulses. Using interference and shadow photography at a time scale of below 10 ns, data on dynamics of vapour expansion are obtained and the electron density in vapour is estimated. Reasons for observed strong screening of the radiation of the second pulse in a tandem are discussed.

  5. Annotated bibliography on high-intensity linear accelerators. [240 citations

    Energy Technology Data Exchange (ETDEWEB)

    Jameson, R.A.; Roybal, E.U.

    1978-01-01

    A technical bibliography covering subjects important to the design of high-intensity beam transport systems and linear accelerators is presented. Space charge and emittance growth are stressed. Subject and author concordances provide cross-reference to detailed citations, which include an abstract and notes on the material. The bibliography resides in a computer database that can be searched for key words and phrases.

  6. Reuse Recycler: High Intensity Proton Stacking at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, P. [Fermilab

    2016-07-17

    After a successful career as an antiproton storage and cooling ring, Recycler has been converted to a high intensity proton stacker for the Main Injector. We discuss the commissioning and operation of the Recycler in this new role, and the progress towards the 700 kW design goal.

  7. High-Intensity Interval Training for Improving Postprandial Hyperglycemia

    Science.gov (United States)

    Little, Jonathan P.; Francois, Monique E.

    2014-01-01

    High-intensity interval training (HIIT) has garnered attention in recent years as a time-efficient exercise option for improving cardiovascular and metabolic health. New research demonstrates that HIIT may be particularly effective for improving postprandial hyperglycemia in individuals with, or at risk for, type 2 diabetes (T2D). These findings…

  8. Clinical applications of high-intensity focused ultrasound.

    Science.gov (United States)

    She, W H; Cheung, T T; Jenkins, C R; Irwin, M G

    2016-08-01

    Ultrasound has been developed for therapeutic use in addition to its diagnostic ability. The use of focused ultrasound energy can offer a non-invasive method for tissue ablation, and can therefore be used to treat various solid tumours. High-intensity focused ultrasound is being increasingly used in the treatment of both primary and metastatic tumours as these can be precisely located for ablation. It has been shown to be particularly useful in the treatment of uterine fibroids, and various solid tumours including those of the pancreas and liver. High-intensity focused ultrasound is a valid treatment option for liver tumours in patients with significant medical co-morbidity who are at high risk for surgery or who have relatively poor liver function that may preclude hepatectomy. It has also been used as a form of bridging therapy while patients awaiting cadaveric donor liver transplantation. In this article, we outline the principles of high-intensity focused ultrasound and its clinical applications, including the management protocol development in the treatment of hepatocellular carcinoma in Hong Kong by performing a search on MEDLINE (OVID), EMBASE, and PubMed. The search of these databases ranged from the date of their establishment until December 2015. The search terms used were: high-intensity focused ultrasound, ultrasound, magnetic resonance imaging, liver tumour, hepatocellular carcinoma, pancreas, renal cell carcinoma, prostate cancer, breast cancer, fibroids, bone tumour, atrial fibrillation, glaucoma, Parkinson's disease, essential tremor, and neuropathic pain.

  9. Influence of high intensity ultrasound with different probe diameter ...

    African Journals Online (AJOL)

    The main goal of this research is to analyze the influence of ultrasonic probe diameters (7 and 10 mm) of high-intensity ultrasound with constant frequency (30 kHz) on the degree of homogenization (variance) of cow milk. Influence of different probe diameters on the physical properties of cow milk was also tested. Changes ...

  10. Pedalling rate affects endurance performance during high-intensity cycling

    DEFF Research Database (Denmark)

    Nielsen, Jens Steen; Hansen, Ernst Albin; Sjøgaard, Gisela

    2004-01-01

    The purpose of this study into high-intensity cycling was to: (1) test the hypothesis that endurance time is longest at a freely chosen pedalling rate (FCPR), compared to pedalling rates 25% lower (FCPR-25) and higher (FCPR+25) than FCPR, and (2) investigate how physiological variables, such as m...

  11. Transverse pump-probe microscopy of moving breakdown, filamentation and self-organized absorption in alkali aluminosilicate glass using ultrashort pulse laser

    OpenAIRE

    Grossmann, D.; Reininghaus, M.; Kalupka, C.; Kumkar, M.; Poprawe, R.

    2016-01-01

    We present time and space resolved transverse pump-probe measurements of the free electron and defect generation induced by nonlinear absorption of ultra short pulsed laser radiation in unhardened Corning Gorilla glass. The applied setup exhibits a 100 fs probe pulse duration and an independent pump pulse duration up to 5 ps. Hence, our work comprises the absorption of ultra short pulsed laser radiation at a wavelength of 800 nm and pulse energies from 10 μJ to 50 μJ up to a delay of 6 ns. Ou...

  12. Quantum state engineering with ultra-short-period (AlN)m/(GaN)n superlattices for narrowband deep-ultraviolet detection.

    Science.gov (United States)

    Gao, Na; Lin, Wei; Chen, Xue; Huang, Kai; Li, Shuping; Li, Jinchai; Chen, Hangyang; Yang, Xu; Ji, Li; Yu, Edward T; Kang, Junyong

    2014-12-21

    Ultra-short-period (AlN)m/(GaN)n superlattices with tunable well and barrier atomic layer numbers were grown by metal-organic vapour phase epitaxy, and employed to demonstrate narrowband deep ultraviolet photodetection. High-resolution transmission electron microscopy and X-ray reciprocal space mapping confirm that superlattices containing well-defined, coherently strained GaN and AlN layers as thin as two atomic layers (∼ 0.5 nm) were grown. Theoretical and experimental results demonstrate that an optical absorption band as narrow as 9 nm (210 meV) at deep-ultraviolet wavelengths can be produced, and is attributable to interband transitions between quantum states along the [0001] direction in ultrathin GaN atomic layers isolated by AlN barriers. The absorption wavelength can be precisely engineered by adjusting the thickness of the GaN atomic layers because of the quantum confinement effect. These results represent a major advance towards the realization of wavelength selectable and narrowband photodetectors in the deep-ultraviolet region without any additional optical filters.

  13. High-Intensity Focused Ultrasound Therapy: an Overview for Radiologists

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Sun; Rhim, Hyun Chul; Lim, Hyo Keun; Choi, Dong Il [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Choi, Min Joo [College of Medicine, Cheju National University, Jeju (Korea, Republic of)

    2008-08-15

    High-intensity focused ultrasound therapy is a novel, emerging, therapeutic modality that uses ultrasound waves, propagated through tissue media, as carriers of energy. This completely non-invasive technology has great potential for tumor ablation as well as hemostasis, thrombolysis and targeted drug/gene delivery. However, the application of this technology still has many drawbacks. It is expected that current obstacles to implementation will be resolved in the near future. In this review, we provide an overview of high-intensity focused ultrasound therapy from the basic physics to recent clinical studies with an interventional radiologist's perspective for the purpose of improving the general understanding of this cutting-edge technology as well as speculating on future developments

  14. Review of High-intensity Interval Training in Cardiac Rehabilitation.

    Science.gov (United States)

    Ito, Shigenori; Mizoguchi, Tatsuya; Saeki, Tomoaki

    2016-01-01

    For the secondary prevention of cardiovascular disease, comprehensive cardiac rehabilitation is required. This involves optimal medical therapy, education on nutrition and exercise therapy, and smoking cessation. Of these, efficient exercise therapy is a key factor. A highly effective training protocol is therefore warranted, which requires a high rate of compliance. Although moderate-intensity continuous training has been the main training regimen recommended in cardiac rehabilitation guidelines, high-intensity interval training has been reported to be more effective in the clinical and experimental setting from the standpoint of peak oxygen uptake and central and peripheral adaptations. In this review, we illustrate the scientific evidence for high-intensity interval training. We then verify this evidence and discuss its significance and the remaining issues.

  15. Engineering Food Ingredients with High-Intensity Ultrasound

    Science.gov (United States)

    Weiss, Jochen; Kristbergsson, Kristberg; Kjartansson, Gunnar Thor

    The use of ultrasound in the food industry has increased in the last decades. Ultrasound has been used both to analyze food structure and composition at low ultrasonic intensities and high frequencies and to modify ingredients at high ultrasonic intensities and low frequencies. Application of the latter is referred to as high-intensity (power) ultrasonication and is generally carried out at frequencies of =0.1 MHz and ultrasonic intensities of 10-100 W cm-2. In the food industry, power ultrasonication has proved to be a highly effective food processing and preservation technology, and use of high-intensity ultrasound with or without heat may be used, for example, to denature enzymes, aid in the extraction of valuable compounds from plants and seeds, tenderize meat, and homogenize or disperse two-phase systems such as emulsions or suspensions (Mason et al., 1996).

  16. NUMERICAL METHODS FOR THE SIMULATION OF HIGH INTENSITY HADRON SYNCHROTRONS.

    Energy Technology Data Exchange (ETDEWEB)

    LUCCIO, A.; D' IMPERIO, N.; MALITSKY, N.

    2005-09-12

    Numerical algorithms for PIC simulation of beam dynamics in a high intensity synchrotron on a parallel computer are presented. We introduce numerical solvers of the Laplace-Poisson equation in the presence of walls, and algorithms to compute tunes and twiss functions in the presence of space charge forces. The working code for the simulation here presented is SIMBAD, that can be run as stand alone or as part of the UAL (Unified Accelerator Libraries) package.

  17. Spallation neutron source and other high intensity froton sources

    Energy Technology Data Exchange (ETDEWEB)

    Weiren Chou

    2003-02-06

    This lecture is an introduction to the design of a spallation neutron source and other high intensity proton sources. It discusses two different approaches: linac-based and synchrotron-based. The requirements and design concepts of each approach are presented. The advantages and disadvantages are compared. A brief review of existing machines and those under construction and proposed is also given. An R&D program is included in an appendix.

  18. Light and Light Sources High-Intensity Discharge Lamps

    CERN Document Server

    Flesch, Peter G

    2006-01-01

    Light and Light Sources gives an introduction to the working principles of high-intensity discharge (HID) lamps and points out challenges and problems associated with the development and operation of HID lamps. The state-of-the-art in electrode and plasma diagnostics as well as numerical methods used for the understanding of HID lamps are described. This volume addresses students as well as scientists and researchers at universities and in industry.

  19. Ion source and injection line for high intensity medical cyclotron.

    Science.gov (United States)

    Jia, XianLu; Guan, Fengping; Yao, Hongjuan; Zhang, TianJue; Yang, Jianjun; Song, Guofang; Ge, Tao; Qin, Jiuchang

    2014-02-01

    A 14 MeV high intensity compact cyclotron, CYCIAE-14, was built at China Institute of Atomic Energy (CIAE). An injection system based on the external H- ion source was used on CYCIAE-14 so as to provide high intensity beam, while most positron emission tomography cyclotrons adopt internal ion source. A beam intensity of 100 μA/14 MeV was extracted from the cyclotron with a small multi-cusp H- ion source (CIAE-CH-I type) and a short injection line, which the H- ion source of 3 mA/25 keV H- beam with emittance of 0.3π mm mrad and the injection line of with only 1.2 m from the extraction of ion source to the medial plane of the cyclotron. To increase the extracted beam intensity of the cyclotron, a new ion source (CIAE-CH-II type) of 9.1 mA was used, with maximum of 500 μA was achieved from the cyclotron. The design and test results of the ion source and injection line optimized for high intensity acceleration will be given in this paper.

  20. Evidence based exercise - clinical benefits of high intensity interval training.

    Science.gov (United States)

    Shiraev, Tim; Barclay, Gabriella

    2012-12-01

    Aerobic exercise has a marked impact on cardiovascular disease risk. Benefits include improved serum lipid profiles, blood pressure and inflammatory markers as well as reduced risk of stroke, acute coronary syndrome and overall cardiovascular mortality. Most exercise programs prescribed for fat reduction involve continuous, moderate aerobic exercise, as per Australian Heart Foundation clinical guidelines. This article describes the benefits of exercise for patients with cardiovascular and metabolic disease and details the numerous benefits of high intensity interval training (HIIT) in particular. Aerobic exercise has numerous benefits for high-risk populations and such benefits, especially weight loss, are amplified with HIIT. High intensity interval training involves repeatedly exercising at a high intensity for 30 seconds to several minutes, separated by 1-5 minutes of recovery (either no or low intensity exercise). HIT is associated with increased patient compliance and improved cardiovascular and metabolic outcomes and is suitable for implementation in both healthy and 'at risk' populations. Importantly, as some types of exercise are contraindicated in certain patient populations and HIIT is a complex concept for those unfamiliar to exercise, some patients may require specific assessment or instruction before commencing a HIIT program.

  1. Laser-driven plasma photonic crystals for high-power lasers

    Science.gov (United States)

    Lehmann, G.; Spatschek, K. H.

    2017-05-01

    Laser-driven plasma density gratings in underdense plasma are shown to act as photonic crystals for high power lasers. The gratings are created by counterpropagating laser beams that trap electrons, followed by ballistic ion motion. This leads to strong periodic plasma density modulations with a lifetime on the order of picoseconds. The grating structure is interpreted as a plasma photonic crystal time-dependent property, e.g., the photonic band gap width. In Maxwell-Vlasov and particle-in-cell simulations it is demonstrated that the photonic crystals may act as a frequency filter and mirror for ultra-short high-power laser pulses.

  2. The effect of progressive high-intensity inspiratory muscle training and fixed high-intensity inspiratory muscle training on the asymmetry of diaphragm thickness in stroke patients

    OpenAIRE

    Jung, Ju-hyeon; Kim, Nan-soo

    2015-01-01

    [Purpose] This study investigated the effects of progressive load and fixed load high-intensity inspiratory muscle training on the asymmetry of diaphragm thickness in stroke patients. [Subjects] Twenty-one stroke patients were assigned to one of three groups: progressive load high-intensity inspiratory muscle training (n = 8), fixed load high-intensity inspiratory muscle training (n = 6), and controls (n = 7). [Methods] The progressive load and fixed load high-intensity inspiratory muscle tra...

  3. Alpine Skiing as Winter-Time High-Intensity Training.

    Science.gov (United States)

    Stöggl, Thomas Leonhard; Schwarzl, Christoph; Müller, Edith E; Nagasaki, Masaru; Stöggl, Julia; Schönfelder, Martin; Niebauer, Josef

    2017-09-01

    To counteract the winter activity deficit, we set out to analyze cardiorespiratory and metabolic responses of two high-intensity training (HIT) protocols during alpine skiing (AS), cross-country skiing (XCS), and indoor cycling (IC) and the effects of sex, age, and fitness level in this comparison. Nineteen healthy subjects (two age and fitness groups, both sexes) performed AS, XCS, and IC with measurements of oxygen uptake (V˙O2), energy expenditure (EE), HR, lactate, blood glucose and rate of perceived exertion, determined during 4 min of continuous HIT (HITc: 90% HRmax for XCS and IC or short turn skiing during AS) or 10-min intermittent HIT [HITint: 5 × 1 min high intensity (>90% HRmax or short turn skiing), 1 min active recovery]. During all three exercise modes and irrespective of HIT protocols, sex, age, and fitness, participants were able to reach exercise intensities >90% HRmax and >84% V˙O2max. In all exercise modes 10-min of HITint with a 10-min postexercise O2 consumption phase resulted in greater mean EE per minute compared to 4-min HITc with 10 min postexercise O2 consumption. When applying the same HIT loading and recovery pattern to all three exercise modes, EE during approximately 1:15 h of AS was equivalent to about 1:00 h of either XCS or IC. Across all exercise modes and HIT protocols, high cardiorespiratory and metabolic responses were achieved regardless of age, sex, or fitness. EE during AS can be maximized by choosing the skiing mode "short turn skiing" in combination with an HITint to prolong the duration of continuous high-intensity loading during each descent. Therefore, all exercise modes and both HIT protocols are applicable and feasible in a broad spectrum of healthy subjects.

  4. Beam halo in high-intensity hadron linacs

    Energy Technology Data Exchange (ETDEWEB)

    Gerigk, F.

    2006-12-21

    This document aims to cover the most relevant mechanisms for the development of beam halo in high-intensity hadron linacs. The introduction outlines the various applications of high-intensity linacs and it will explain why, in the case of the CERN Superconducting Proton Linac (SPL) study a linac was chosen to provide a high-power beam, rather than a different kind of accelerator. The basic equations, needed for the understanding of halo development are derived and employed to study the effects of initial and distributed mismatch on high-current beams. The basic concepts of the particle-core model, envelope modes, parametric resonances, the free-energy approach, and the idea of core-core resonances are introduced and extended to study beams in realistic linac lattices. The approach taken is to study the behavior of beams not only in simplified theoretical focusing structures but to highlight the beam dynamics in realistic accelerators. All effects which are described and derived with simplified analytic models, are tested in realistic lattices and are thus related to observable effects in linear accelerators. This approach involves the use of high-performance particle tracking codes, which are needed to simulate the behavior of the outermost particles in distributions of up to 100 million macro particles. In the end a set of design rules are established and their impact on the design of a typical high-intensity machine, the CERN SPL, is shown. The examples given in this document refer to two different design evolutions of the SPL study: the first conceptual design report (SPL I) and the second conceptual design report (SPL II). (orig.)

  5. Liquid chromatographic high-throughput analysis of the new ultra-short acting hypnotic 'HIE-124' and its metabolite in mice serum using a monolithic silica column.

    Science.gov (United States)

    Kadi, Adnan; Hefnawy, Mohamed; Al-Majed, Abdulrhman; Alonezi, Sanad; Asiri, Yousif; Attia, Sabry; Abourashed, Ehab; El-Subbagh, Hussein

    2011-02-07

    For the first time, a fast, high-performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of the new ultra-short hypnotic HIE-124 and its metabolite in mice serum. Each compound, together with carbamazepine (internal standard) was extracted from the serum matrix using liquid-liquid extraction (LLE). Chromatographic resolution of the analytes was performed on a Chromolith Speed Rod monolithic silica column (100 mm × 4.6 mm i.d.) under isocratic conditions using a mobile phase of 65:35 (v/v), 20 mM phosphate buffer (pH 7.0 adjusted with phosphoric acid)-acetonitrile. The elution of the analytes were monitored at 240 nm and conducted at ambient temperature. Because of high column efficiency the mobile phase was pumped at a flow rate of 2.5 mL min(-1). The total run time of the assay was 2 min. The method was validated over the range of 60-2000 ng mL(-1) for HIE-124 and 200-1600 ng mL(-1) for the metabolite (r(2) = 0.99). The limit of detection (LOD) for HIE-124 and its metabolite were 20 ng mL(-1) and 65 ng mL(-1), respectively. The proposed method was validated in compliance with ICH guidelines, in terms of accuracy, precision, limits of detection and quantitation and other aspects of analytical validation. The developed method could be used for the trace analyses of HIE-124 and its metabolite in serum and was finally used for the pharmacokinetic study investigation of HIE-124 in mice serum.

  6. Formation of high intensity ion beams with ballistic focusing

    Science.gov (United States)

    Koval, T. V.; Ryabchikov, A. I.; Shevelev, A. E.; Kim, An Tran My; Tarakanov, V. P.

    2017-11-01

    This investigation presents the results of experimental investigation and theoretical simulations of the influence of plasma and negative bias parameters on formation, transportation and focusing of high intensity ion beams of titanium and nitrogen (with an ion current density up to 1 A/cm2 and pulsed power density up to 2.6 kW/cm2). It was shown that the conditions of space charge neutralization of the focusing beam have a significant influence on the distribution and magnitude of the ion current at the collector.

  7. Lead paint removal with high-intensity light pulses.

    Science.gov (United States)

    Grapperhaus, Michael J; Schaefer, Raymond B

    2006-12-15

    This paper presents the results of an initial investigation into using high-intensity incoherent light pulses to strip paint. Measurements of light pulse characteristics, the reflectivity of different paints and initial experiments on the threshold for paint removal, and paint removal are presented, along with an approximate model consistent with experimental results. Paint removal tests include lead paint, the reduction of lead levels to below levels required for lead abatement, as well as air and light emissions measurements that are within regulatory guidelines.

  8. Hunting for new, weakly coupled particles with high intensities

    Energy Technology Data Exchange (ETDEWEB)

    Doebrich, Babette [CERN, 1211 Geneva 23 (Switzerland)

    2016-07-01

    A number of smaller and diverse experiments complements the high-energy explorations for new physics at the LHC. Many of these experiments are searching for new physics hiding at comparably low mass but very weak coupling. Examples of such particles are axion-like particles and dark gauge bosons, which could also explain Dark Matter. The technology to directly search for such particles are often high-intensity and precision set-ups. In my talk I give a brief overview of the motivation and search for axion-like particles and then focus on the possibility to find them in a proton-dump experiment at CERN.

  9. Investigation on Beam Dynamics Design of High-Intensity RFQs

    CERN Document Server

    Zhang, C

    2004-01-01

    Recently various potential uses of high-intensity beams bring new opportunities as well as challenges to RFQ accelerator research because of the new problems arising from the strong space-charge effects. Unconventional concepts of beam dynamics design, which surround the choice of basic parameters and the optimization of main dynamics parameters’ variation along the machine, are illustrated by the designing Peking University (PKU) Deuteron RFQ. An efficient tool of LANL RFQ Design Codes for beam dynamics simulation and analysis, RFQBAT, is introduced. Some quality criterions are also presented for evaluating design results.

  10. Proton and Ion Sources for High Intensity Accelerators

    CERN Multimedia

    Scrivens, R

    2004-01-01

    Future high intensity ion accelerators, including the Spallation Neutron Source (SNS), the European Spallation Source (ESS), the Superconducting Proton Linac (SPL) etc, will require high current and high duty factor sources for protons and negative hydrogen ions. In order to achieve these goals, a comparison of the Electron Cyclotron Resonance, radio-frequency and Penning ion sources, among others, will be made. For each of these source types, the present operational sources will be compared to the state-of-the-art research devices with special attention given to reliability and availability. Finally, the future research and development aims will be discussed.

  11. The joint project for high-intensity proton accelerators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-08-01

    Japan Atomic Energy Research Institute (JAERI) and the High Energy Accelerator Research Organization (KEK) agreed to promote the joint project integrating both the Neutron Science Project (NSP) of JAERI and the Japan Hadron Facility Project (JHF) of KEK for comprehensive studies on basic science and technology using high-intensity proton accelerator. This document describes the joint proposal prepared by the Joint Project Team of JAERI and KEK to construct accelerators and research facilities necessary both for the NSP and the JHF at the site of JAERI Tokai Establishment. (author)

  12. Feasibility study on temporal-resolved diffraction of high-energy electrons produced in femtosecond laser-plasmas

    CERN Document Server

    Zhang Jun; Cang Yu; Chen Qing; Peng Lian Mao; Wang Huai Bin; Zhong Jia Yong

    2002-01-01

    The high-energy electrons can be produced in the interaction between intense ultra-short laser pulses and Al targets. The diffraction may take place when high-energy electrons pass through an Al single crystal. Feasibility is studied using such diffraction as a method to analyze the structures of crystals

  13. TT40 Damage during 2004 High Intensity SPS Extraction

    CERN Document Server

    Goddard, B; Mertens, V; Uythoven, J; Wenninger, J; CERN. Geneva. AB Department

    2005-01-01

    During high intensity extraction on 25/10/04 an incident occurred in which the vacuum chamber of the TT40 magnet QTRF4002 was badly damaged. The beam was a 450 GeV full LHC injection batch of 3.4 1013 p+ in 288 bunches, and was extracted from SPS LSS4 with the wrong trajectory. Prior to the fatal extraction, problems had occurred over several hours during the setting-up, with beam-induced noise causing the extraction septum interlock to trip the power convertor, and also with the bumped beam position interlock. Deficiencies in the extraction setting-up process, in the interlocking and in the operational procedures used for the high-intensity test were contributing factors. In this note the incident causes are identified, the details reconstructed from the logged data, and the damage to the vacuum chamber analysed. The remedial measures which have already been taken are explained, and further recommendations made concerning the interlocking system performance and tests, as well as the operational procedures wh...

  14. High-intensity interval training in cardiac rehabilitation.

    Science.gov (United States)

    Guiraud, Thibaut; Nigam, Anil; Gremeaux, Vincent; Meyer, Philippe; Juneau, Martin; Bosquet, Laurent

    2012-07-01

    High-intensity interval training (HIIT) is frequently used in sports training. The effects on cardiorespiratory and muscle systems have led scientists to consider its application in the field of cardiovascular diseases. The objective of this review is to report the effects and interest of HIIT in patients with coronary artery disease (CAD) and heart failure (HF), as well as in persons with high cardiovascular risk. A non-systematic review of the literature in the MEDLINE database using keywords 'exercise', 'high-intensity interval training', 'interval training', 'coronary artery disease', 'coronary heart disease', 'chronic heart failure' and 'metabolic syndrome' was performed. We selected articles concerning basic science research, physiological research, and randomized or non-randomized interventional clinical trials published in English. To summarize, HIIT appears safe and better tolerated by patients than moderate-intensity continuous exercise (MICE). HIIT gives rise to many short- and long-term central and peripheral adaptations in these populations. In stable and selected patients, it induces substantial clinical improvements, superior to those achieved by MICE, including beneficial effects on several important prognostic factors (peak oxygen uptake, ventricular function, endothelial function), as well as improving quality of life. HIIT appears to be a safe and effective alternative for the rehabilitation of patients with CAD and HF. It may also assist in improving adherence to exercise training. Larger randomized interventional studies are now necessary to improve the indications for this therapy in different populations.

  15. High intensity surface plasma waves, theory and PIC simulations

    Science.gov (United States)

    Raynaud, M.; Héron, A.; Adam, J.-C.

    2018-01-01

    With the development of intense (>1019 W cm‑2) short pulses (≤25 fs) laser with very high contrast, surface plasma wave (SPW) can be explored in the relativistic regime. As the SPW propagates with a phase velocity close to the speed of light it may results in a strong acceleration of electron bunches along the surface permitting them to reach relativistic energies. This may be important e.g. for applications in the field of plasma-based accelerators. We investigate in this work the excitation of SPWs on grating preformed over-dense plasmas for laser intensities ranging from 1019 up to 1021 W cm‑2. We discuss the nature of the interaction with respect to the solid case in which surface plasmon can be resonantly excited with weak laser intensity. In particular, we show the importance of the pulse duration and focalization of the laser beam on the amplitude of the SPW.

  16. High Intensity Beam and X-Ray Converter Target Interactions and Mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Chem, Y-J; McCarrick, J F; Guethlein, G; Chambers, F; Falabella, S; Lauer, E; Richardson, R; Weir, J

    2002-07-31

    Ions extracted from a solid surface or plasma by impact of an high intensity and high current electron beam can partially neutralize the beam space charge and change the focusing system. We have investigated ion emission computationally and experimentally. By matching PIC simulation results with available experimental data, our finding suggests that if a mix of ion species is available at the emitting surface, protons dominate the backstreaming ion effects, and that, unless there is surface flashover, ion emission is source limited. We have also investigated mitigation, such as e-beam cleaning, laser cleaning and ion trapping with a foil barrier. The temporal behavior of beam spot size with a foil barrier and a focusing scheme to improve foil barrier performance are discussed.

  17. Proposed Few-optical Cycle Laser-driven ParticleAccelerator Structure

    Energy Technology Data Exchange (ETDEWEB)

    Plettner, T.; Lu, P.; Byer, R.L.; /Stanford U., Ginzton Lab.

    2006-10-06

    We describe a transparent dielectric grating accelerator structure that is designed for ultra-short laser pulse operation. The structure is based on the principle of periodic field reversal to achieve phase synchronicity for relativistic particles, however to preserve ultra-short pulse operation it does not resonate the laser field in the vacuum channel. The geometry of the structure appears well suited for application with high average power lasers and high thermal loading. Finally, it shows potential for an unloaded gradient of 10 GeV/m with 10 fsec laser pulses and the possibility to accelerate 10{sup 6} electrons per bunch at an efficiency of 8%. The fabrication procedure and a proposed near term experiment with this accelerator structure are presented.

  18. High-Intensity Focused Ultrasound Treatment for Advanced Pancreatic Cancer

    Directory of Open Access Journals (Sweden)

    Yufeng Zhou

    2014-01-01

    Full Text Available Pancreatic cancer is under high mortality but has few effective treatment modalities. High-intensity focused ultrasound (HIFU is becoming an emerging approach of noninvasively ablating solid tumor in clinics. A variety of solid tumors have been tried on thousands of patients in the last fifteen years with great success. The principle, mechanism, and clinical outcome of HIFU were introduced first. All 3022 clinical cases of HIFU treatment for the advanced pancreatic cancer alone or in combination with chemotherapy or radiotherapy in 241 published papers were reviewed and summarized for its efficacy, pain relief, clinical benefit rate, survival, Karnofsky performance scale (KPS score, changes in tumor size, occurrence of echogenicity, serum level, diagnostic assessment of outcome, and associated complications. Immune response induced by HIFU ablation may become an effective way of cancer treatment. Comments for a better outcome and current challenges of HIFU technology are also covered.

  19. High Intensity Interval Training for Maximizing Health Outcomes.

    Science.gov (United States)

    Karlsen, Trine; Aamot, Inger-Lise; Haykowsky, Mark; Rognmo, Øivind

    Regular physical activity and exercise training are important actions to improve cardiorespiratory fitness and maintain health throughout life. There is solid evidence that exercise is an effective preventative strategy against at least 25 medical conditions, including cardiovascular disease, stroke, hypertension, colon and breast cancer, and type 2 diabetes. Traditionally, endurance exercise training (ET) to improve health related outcomes has consisted of low- to moderate ET intensity. However, a growing body of evidence suggests that higher exercise intensities may be superior to moderate intensity for maximizing health outcomes. The primary objective of this review is to discuss how aerobic high-intensity interval training (HIIT) as compared to moderate continuous training may maximize outcomes, and to provide practical advices for successful clinical and home-based HIIT. Copyright © 2017. Published by Elsevier Inc.

  20. Fermilab main injector: High intensity operation and beam loss control

    Directory of Open Access Journals (Sweden)

    Bruce C. Brown

    2013-07-01

    Full Text Available From 2005 through 2012, the Fermilab Main Injector provided intense beams of 120 GeV protons to produce neutrino beams and antiprotons. Hardware improvements in conjunction with improved diagnostics allowed the system to reach sustained operation at 400 kW beam power. Transmission was very high except for beam lost at or near the 8 GeV injection energy where 95% beam transmission results in about 1.5 kW of beam loss. By minimizing and localizing loss, residual radiation levels fell while beam power was doubled. Lost beam was directed to either the collimation system or to the beam abort. Critical apertures were increased while improved instrumentation allowed optimal use of available apertures. We will summarize the improvements required to achieve high intensity, the impact of various loss control tools and the status and trends in residual radiation in the Main Injector.

  1. High Intensity Beam Issues in the CERN Proton Synchrotron

    CERN Document Server

    Aumon, Sandra; Rivkin, Leonid

    This PhD work is about limitations of high intensity proton beams observed in the CERN Proton Synchrotron (PS) and, in particular, about issues at injection and transition energies. With its 53 years, the CERN PS would have to operate beyond the limit of its performance to match the future requirements. Beam instabilities driven by transverse impedance and aperture restrictions are important issues for the operation and for the High-Luminosity LHC upgrade which foresees an intensity increase delivered by the injectors. The main subject of the thesis concerns the study of a fast transverse instability occurring at transition energy. The proton beams crossing this energy range are particularly sensitive to wake forces because of the slow synchrotron motion. This instability can cause a strong vertical emittance blow-up and severe losses in less than a synchrotron period. Experimental observations show that the particles at the peak density of the beam longitudinal distribution oscillate in the vertical plane du...

  2. High-intensity therapeutic ultrasound: metrological requirements versus clinical usage

    Science.gov (United States)

    Aubry, J.-F.

    2012-10-01

    High-intensity therapeutic ultrasound (HITU) is an appealing non-invasive, non-ionizing therapeutic modality with a wide range of tissue interactions ranging from transient permeabilization of cell membranes to thermal ablation. The ability to guide and monitor the treatment with an associated ultrasonic or magnetic resonance imaging device has resulted in a dramatic rise in the clinical use of therapeutic ultrasound in the past two decades. Nevertheless, the range of clinical applications and the number of patients treated has grown at a much higher pace than the definition of standards. In this paper the metrological requirements of the therapeutic beams are reviewed and are compared with the current clinical use of image-guided HITU mostly based on a practical approach. Liver therapy, a particularly challenging clinical application, is discussed to highlight the differences between some complex clinical situations and the experimental conditions of the metrological characterization of ultrasonic transducers.

  3. Adaptive RF Transient Reduction for HIGH Intensity Beams with Gaps

    CERN Document Server

    Tückmantel, Joachim

    2006-01-01

    When a high-intensity beam with bunch-trains and gaps passes a cavity with a high-gain vector feedback enforcing a constant voltage, large transients appear, stressing the RF high power hardware and increasing the trip rate. By modulating the cavity voltage with a varying periodic waveform (set-function), the RF power can be made constant while still preserving the high feedback gain. The average cavity voltage is conserved but bunches have to settle at slightly shifted positions. A method is derived to obtain this set-function in practice while making no assumptions or measurements of the beam or RF parameters. Adiabatic iterations are made including the whole machine as an analog computing device, using all parameters as they are. A computer simulation shows the success of the method.

  4. Fast damping in mismatched high intensity beam transportation

    Directory of Open Access Journals (Sweden)

    V. Variale

    2001-08-01

    Full Text Available A very fast damping of beam envelope oscillation amplitudes was recently observed in simulations of high intensity beam transport, through periodic FODO cells, in mismatched conditions [V. Variale, Nuovo Cimento Soc. Ital. Fis. 112A, 1571–1582 (1999 and T. Clauser et al., in Proceedings of the Particle Accelerator Conference, New York, 1999 (IEEE, Piscataway, NJ, 1999, p. 1779]. A Landau damping mechanism was proposed at the origin of observed effect. In this paper, to further investigate the source of this fast damping, extensive simulations have been carried out. The results presented here support the interpretation of the mechanism at the origin of the fast damping as a Landau damping effect.

  5. The High-Intensity Hyperon Beam at CERN

    CERN Document Server

    Aleksandrov, Yu.A.; Dropmann, F.; Fournier, A.; Grafstrom, P.; Hubbard, E.; Paul, S.; Siebert, H.W.; Trombini, A.; Zavertyaev, M.

    1998-01-01

    A high-intensity hyperon beam was constructed at CERN to deliver S- to experiment WA89 at the Omega facility and operated from 1989 to 1994. The setup allowed rapid changeover between hyperon and conventional hadron beam configurations. The beam provided a S- flux of 1.4 x 105 per burst at mean momenta between 330 and 345 GeV/c produced by about 3 x 1010 protons of 450 GeV/c. At the experiment target the beam had a S-/p- ratio close to 0.4 and a size of 1.6 x 3.7 cm2. The beam particle trajectories and their momenta were measured with a scintillating fibre hodoscope in the beam channel and a silicon microstrip detector at the exit of the channel. A fast transition radiation detector was used to identify the pion component of the beam

  6. High intensity ion beams in rf undulator linac

    Directory of Open Access Journals (Sweden)

    E. S. Masunov

    2008-07-01

    Full Text Available The possibility of using a radio frequency undulator field to accelerate a high intensity ion beam in a linac is discussed. Such an accelerator can be realized using the periodical interdigital H-type resonator structure. The accelerating force is produced by an electric field which is a combination of two or more spatial harmonics, none of them being synchronous with the ion beam. The value of this force is proportional to the squared charge. The equations of motion in Hamiltonian form are derived by means of smooth approximation. The analysis of the 3D effective potential function allows finding the conditions of the beam focusing and acceleration. Two ways to increase ion beam intensity are considered: (i to enlarge beam cross section; (ii to neutralize the beam space charge by accelerating ions with opposite charge signs within the same bunch. The basic results are confirmed by a numerical simulation.

  7. Cardiac-respiratory self-gated cine ultra-short echo time (UTE) cardiovascular magnetic resonance for assessment of functional cardiac parameters at high magnetic fields.

    Science.gov (United States)

    Hoerr, Verena; Nagelmann, Nina; Nauerth, Arno; Kuhlmann, Michael T; Stypmann, Jörg; Faber, Cornelius

    2013-07-04

    To overcome flow and electrocardiogram-trigger artifacts in cardiovascular magnetic resonance (CMR), we have implemented a cardiac and respiratory self-gated cine ultra-short echo time (UTE) sequence. We have assessed its performance in healthy mice by comparing the results with those obtained with a self-gated cine fast low angle shot (FLASH) sequence and with echocardiography. 2D self-gated cine UTE (TE/TR = 314 μs/6.2 ms, resolution: 129 × 129 μm, scan time per slice: 5 min 5 sec) and self-gated cine FLASH (TE/TR = 3 ms/6.2 ms, resolution: 129 × 129 μm, scan time per slice: 4 min 49 sec) images were acquired at 9.4 T. Volume of the left and right ventricular (LV, RV) myocardium as well as the end-diastolic and -systolic volume was segmented manually in MR images and myocardial mass, stroke volume (SV), ejection fraction (EF) and cardiac output (CO) were determined. Statistical differences were analyzed by using Student t test and Bland-Altman analyses. Self-gated cine UTE provided high quality images with high contrast-to-noise ratio (CNR) also for the RV myocardium (CNRblood-myocardium = 25.5 ± 7.8). Compared to cine FLASH, susceptibility, motion, and flow artifacts were considerably reduced due to the short TE of 314 μs. The aortic valve was clearly discernible over the entire cardiac cycle. Myocardial mass, SV, EF and CO determined by self-gated UTE were identical to the values measured with self-gated FLASH and showed good agreement to the results obtained by echocardiography. Self-gated UTE allows for robust measurement of cardiac parameters of diagnostic interest. Image quality is superior to self-gated FLASH, rendering the method a powerful alternative for the assessment of cardiac function at high magnetic fields.

  8. EDITORIAL: Laser and plasma accelerators Laser and plasma accelerators

    Science.gov (United States)

    Bingham, Robert

    2009-02-01

    This special issue on laser and plasma accelerators illustrates the rapid advancement and diverse applications of laser and plasma accelerators. Plasma is an attractive medium for particle acceleration because of the high electric field it can sustain, with studies of acceleration processes remaining one of the most important areas of research in both laboratory and astrophysical plasmas. The rapid advance in laser and accelerator technology has led to the development of terawatt and petawatt laser systems with ultra-high intensities and short sub-picosecond pulses, which are used to generate wakefields in plasma. Recent successes include the demonstration by several groups in 2004 of quasi-monoenergetic electron beams by wakefields in the bubble regime with the GeV energy barrier being reached in 2006, and the energy doubling of the SLAC high-energy electron beam from 42 to 85 GeV. The electron beams generated by the laser plasma driven wakefields have good spatial quality with energies ranging from MeV to GeV. A unique feature is that they are ultra-short bunches with simulations showing that they can be as short as a few femtoseconds with low-energy spread, making these beams ideal for a variety of applications ranging from novel high-brightness radiation sources for medicine, material science and ultrafast time-resolved radiobiology or chemistry. Laser driven ion acceleration experiments have also made significant advances over the last few years with applications in laser fusion, nuclear physics and medicine. Attention is focused on the possibility of producing quasi-mono-energetic ions with energies ranging from hundreds of MeV to GeV per nucleon. New acceleration mechanisms are being studied, including ion acceleration from ultra-thin foils and direct laser acceleration. The application of wakefields or beat waves in other areas of science such as astrophysics and particle physics is beginning to take off, such as the study of cosmic accelerators considered

  9. Tailoring of Highly Intense THz Radiation Through High Brightness Electron Beams Longitudinal Manipulation

    Directory of Open Access Journals (Sweden)

    Flavio Giorgianni

    2016-02-01

    Full Text Available The ultra-short electron beams, produced through the velocity bunching compression technique at the SPARC_LAB test Facility (Frascati, Italy, are used to produce Coherent Transition Radiation in the terahertz (THz range. This paper reports on the main features of this THz source, which have a spectral coverage up to 5 THz, a pulse duration down to 100 fs, and an energy per pulse on the order of tens of μJ. These figures of merits open the possibility to apply this source for nonlinear and THz pump-probe experiments in Solid-State Physics and material science.

  10. Robotic Assisted Laparoscopic Prostatectomy after High Intensity Focused Ultrasound Failure

    Directory of Open Access Journals (Sweden)

    Leon Telis

    2017-01-01

    Full Text Available Background. Prostate cancer is the most common cancer diagnosed in men. As new focal therapies become more popular in treatment of prostate cancer, failure cases requiring salvage therapy with either surgical or other techniques are being reported. Objective. To report the options in treatment of prostate cancer after recurrence or failure of the primary treatment modality. Methods. We report a salvage robotic assisted laparoscopic radical prostatectomy (RALP for prostate cancer recurrence following high intensity focused ultrasound treatment (HIFU in the United States. Results. A 67-year-old man who underwent HIFU treatment for prostate adenocarcinoma 2 years prior was presented with a rising prostate specific antigen of 6.1 ng/mL to our clinic. A biopsy proven recurrent disease in the area of previous treatment documented the failure of treatment. The patient elected to undergo a salvage RALP. The operation time was 159 minutes. The patient was discharged from the hospital on postoperative day 1 with no complications. The catheter was removed on post-op day 10. The patient reserved sexual function and urinary continence. The PSA levels on 6 months’ follow-up are undetectable. Conclusions. Salvage RALP is an effective and safe treatment choice for recurrent prostate adenocarcinoma following failed HIFU treatment if operated by an experienced surgeon.

  11. High intensity focused ultrasound in clinical tumor ablation

    Science.gov (United States)

    Zhou, Yu-Feng

    2011-01-01

    Recent advances in high intensity focused ultrasound (HIFU), which was developed in the 1940s as a viable thermal tissue ablation approach, have increased its popularity. In clinics, HIFU has been applied to treat a variety of solid malignant tumors in a well-defined volume, including the pancreas, liver, prostate, breast, uterine fibroids, and soft-tissue sarcomas. In comparison to conventional tumor/cancer treatment modalities, such as open surgery, radio- and chemo-therapy, HIFU has the advantages of non-invasion, non-ionization, and fewer complications after treatment. Over 100 000 cases have been treated throughout the world with great success. The fundamental principles of HIFU ablation are coagulative thermal necrosis due to the absorption of ultrasound energy during transmission in tissue and the induced cavitation damage. This paper reviews the clinical outcomes of HIFU ablation for applicable cancers, and then summarizes the recommendations for a satisfactory HIFU treatment according to clinical experience. In addition, the current challenges in HIFU for engineers and physicians are also included. More recent horizons have broadened the application of HIFU in tumor treatment, such as HIFU-mediated drug delivery, vessel occlusion, and soft tissue erosion (“histotripsy”). In summary, HIFU is likely to play a significant role in the future oncology practice. PMID:21603311

  12. Multifunctional pulse generator for high-intensity focused ultrasound system

    Science.gov (United States)

    Tamano, Satoshi; Yoshizawa, Shin; Umemura, Shin-Ichiro

    2017-07-01

    High-intensity focused ultrasound (HIFU) can achieve high spatial resolution for the treatment of diseases. A major technical challenge in implementing a HIFU therapeutic system is to generate high-voltage high-current signals for effectively exciting a multichannel HIFU transducer at high efficiencies. In this paper, we present the development of a multifunctional multichannel generator/driver. The generator can produce a long burst as well as an extremely high-voltage short pulse of pseudosinusoidal waves (trigger HIFU) and second-harmonic superimposed waves for HIFU transmission. The transmission timing, waveform, and frequency can be controlled using a field-programmable gate array (FPGA) via a universal serial bus (USB) microcontroller. The hardware is implemented in a compact printed circuit board. The test results of trigger HIFU reveal that the power consumption and the temperature rise of metal-oxide semiconductor field-effect transistors were reduced by 19.9% and 38.2 °C, respectively, from the previous design. The highly flexible performance of the novel generator/driver is demonstrated in the generation of second-harmonic superimposed waves, which is useful for cavitation-enhanced HIFU treatment, although the previous design exhibited difficulty in generating it.

  13. Pulmonary Vein Isolation by High Intensity Focused Ultrasound

    Directory of Open Access Journals (Sweden)

    Matthias Antz

    2007-04-01

    Full Text Available Pulmonary vein isolation (PVI using radiofrequency current (RFC ablation is a potentially curative treatment option for patients with atrial fibrillation (AF. The shortcomings of the RFC technology (technically challenging, long procedure times, complications steadily kindle the interest in new energy sources and catheter designs. High intensity focused ultrasound (HIFU has the ability to precisely focus ultrasound waves in a defined area with a high energy density. HIFU balloon catheters (BC positioned at the PV ostia appear to be an ideal tool to transmit the ablation energy in a circumferential manner to the PV ostia and may therefore bear substantial advantage over conventional ablation catheters in PVI procedures. In clinical trials the HIFU BC has shown promising success rates similar to RFC catheter ablation for PVI in patients with AF. However, procedure times are still long and serious complications have been observed. Therefore, it may be a valuable alternative to the conventional techniques in selected patients but further clinical trials have to be initiated.

  14. Formation of a high intensity low energy positron string

    Science.gov (United States)

    Donets, E. D.; Donets, E. E.; Syresin, E. M.; Itahashi, T.; Dubinov, A. E.

    2004-05-01

    The possibility of a high intensity low energy positron beam production is discussed. The proposed Positron String Trap (PST) is based on the principles and technology of the Electron String Ion Source (ESIS) developed in JINR during the last decade. A linear version of ESIS has been used successfully for the production of intense highly charged ion beams of various elements. Now the Tubular Electron String Ion Source (TESIS) concept is under study and this opens really new promising possibilities in physics and technology. In this report, we discuss the application of the tubular-type trap for the storage of positrons cooled to the cryogenic temperatures of 0.05 meV. It is intended that the positron flux at the energy of 1-5 eV, produced by the external source, is injected into the Tubular Positron Trap which has a similar construction as the TESIS. Then the low energy positrons are captured in the PST Penning trap and are cooled down because of their synchrotron radiation in the strong (5-10 T) applied magnetic field. It is expected that the proposed PST should permit storing and cooling to cryogenic temperature of up to 5×109 positrons. The accumulated cooled positrons can be used further for various physics applications, for example, antihydrogen production.

  15. A methodology for assessing high intensity RF effects in aircraft

    Energy Technology Data Exchange (ETDEWEB)

    Zacharias, R.A.; Avalle, C.A.; Kunz, K.S.; Molau, N.E.; Pennock, S.T.; Poggio, A.J.; Sharpe, R.M.

    1993-07-01

    Optical components have an inherent immunity to the electromagnetic interference (EMI) associated with High Intensity Radiated Fields (HIRF). The optical technology embodied in Fly-by-Light (FBL) might therefore minimize the effects of HIRF on digitally controlled systems while providing lifetime immunity to signal EMI. This is one of the primary motivations for developing FBL systems for aircraft. FBL has the potential to greatly simplify EMI certification by enabling technically acceptable laboratory tests of subsystems, as opposed to expensive full airplane tests. In this paper the authors describe a methodology for assessing EMI effects on FBL aircraft that reduces or potentially eliminates the need for full airplane tests. This methodology is based on comparing the applied EMI stress--the level of interference signal that arrives at a unit under test--versus the EMI strength of the unit--the interference level it can withstand without upset. This approach allows one to use computer models and/or low power coupling measurement and similarity (to other previously tested aircraft) to determine the stress applied to installed subsystems, and to use benchtop cable injection tests and/or mode stirred chamber radiated tests to determine the strength of the subsystem.

  16. Production and Studies of Photocathodes for High Intensity Electron Beams

    CERN Document Server

    Chevallay, E; Legros, P; Suberlucq, Guy; Trautner, H

    2000-01-01

    For short, high-intensity electron bunches, alkali-tellurides have proved to be a reliable photo-cathode material. Measurements of lifetimes in an rf gun of the CLIC Test Facility II at field strengths greater than 100 MV/m are presented. Before and after using them in this gun, the spectral response of the CS-Te and Rb-Te cathodes were determined with the help of an optical parametric oscillator. The behaviour of both materials can be described by Spicer's 3-step model. Whereas during the use the threshold for photo-emission in Cs-Te was shifted to higher proton energies, that of Rb-Te did not change. Our latest investigations on the stoichiometric ratio of the components are shown. The preparation of the photo-cathodes was monitored with 320 nm wavelength light , with the aim of improving the measurement sensitivity. The latest results on the protection of Cs-Te cathode surfaces with CsBr against pollution are summarized. New investigations on high mean current production are presented.,

  17. Design alternatives for beam halo monitors in high intensity accelerators

    CERN Document Server

    Braun, H; Corsini, R; Lefèvre, T; Schulte, Daniel; Tecker, F A; Welsch, C P

    2005-01-01

    In future high intensity, high energy accelerators it must be ensured that particle losses are minimized as activation of the vacuum chambers or other components makes maintenance and upgrade work time consuming and costly. It is imperative to have a clear understanding of the mechanisms that can lead to halo formation and to have the possibility to test available theoretical models with an adequate experimental setup. Optical transition radiation (OTR) provides an interesting opportunity for linear real-time measurements of the transverse beam profile with a resolution which has been so far at best in the some μm range. However, the dynamic range of standard OTR systems is typically limited and needs to be improved for its application for halo measurements. In this contribution, the existing OTR system as it is installed in the CLIC test facility (CTF3) is analyzed and the contribution of each component to the final image quality discussed. Finally, possible halo measurement techniques based on OTR are pres...

  18. Treatment of Acne Scars With High Intensity Focused Radio Frequency.

    Science.gov (United States)

    Ibrahimi, Omar A; Weiss, Robert A; Weiss, Margaret A; Halvorson, Christian R; Mayoral, Flor; Ross, E Victor; Cohen, Joel L

    2015-09-01

    In this multi-site case series, the efficacy of high intensity focused radiofrequency (RF) delivered to the dermis was evaluated for treating acne scars. A novel delivery system that uses insulated microneedles to deliver a desired thermal effect to multiple depths of the dermis while sparing the epidermis from RF injury was used. Four (4) healthy subjects from four different practices were evaluated and used in this case report. The subjects were treated between 3 or 4 times depending on the severity of the acne scars presented. The depth of thermal delivery was adjusted before each pass and all subjects received at a minimum, three passes to the treated area. Before and after photographs along with adverse effects were recorded. The theory behind the use of insulated needles with the active RF delivery at the distal tip is to allow for significant thermal injury to several layers of the dermis while avoiding thermal injury to the epidermis. This case report demonstrates significant improvement on acne scars and that all skin types should be safely treatable with minimum downtime realized.

  19. Perception of Breakfast Ingestion Enhances High Intensity Cycling Performance.

    Science.gov (United States)

    Mears, Stephen A; Dickinson, Kathryn; Bergin-Taylor, Kurt; Dee, Reagan; Kay, Jack; James, Lewis J

    2017-09-27

    To examine the effect on short duration, high intensity cycling time trial performance when a semi-solid breakfast containing carbohydrate or a taste and texture matched placebo is ingested 90 minutes pre-exercise compared to a water control. Thirteen well trained cyclists (25 ± 8 years, 71.1 ± 5.9 kg, 1.76 ± 0.04 m, 383 ± 46 Wmax, VO2peak 4.42 ± 0.53 L·min(-1)) performed three experimental trials examining breakfast ingestion 90 minutes before a 10 minute steady state cycle (60% Wmax) and a ~20 minute time trial (to complete a workload target of 376 ± 36 kJ). Subjects consumed either water (WAT), a semi-solid carbohydrate breakfast (2 g carbohydrate·kg(-1) body mass; CHO) or a taste and texture matched placebo (PLA). Blood lactate and glucose concentrations were measured periodically throughout the rest and exercise periods. The time trial was completed quicker in CHO (1120 ± 69 s; P=0.006) and PLA (1112 ± 50 s; P=0.030) compared to WAT (1146 ± 74 s). Ingestion of carbohydrate caused an increase in blood glucose concentration throughout the rest period in CHO (peak at 30 minutes rest: 7.37 ± 1.10 mmol·l(-1); Pbreakfast (PLA or CHO) 90 minutes prior to the start of exercise. The improvement in performance is likely attributable to a psychological rather than physiological effect.

  20. Creatine kinase response to high-intensity aerobic exercise in adult-onset muscular dystrophy

    DEFF Research Database (Denmark)

    Andersen, Søren P; Sveen, Marie-Louise; Hansen, Regitze S

    2013-01-01

    We investigated the effect of high-intensity exercise on plasma creatine kinase (CK) in patients with muscular dystrophies.......We investigated the effect of high-intensity exercise on plasma creatine kinase (CK) in patients with muscular dystrophies....

  1. Association of serum BDNF concentration with high-intensity interval training

    National Research Council Canada - National Science Library

    東, 宏一郎; 大澤, 祐介; 田畑, 尚吾; 堀澤, 栞里; 勝川, 史憲; 石田, 浩之; 小熊, 祐子; 河合, 俊英; 小口, 修司; 太田, 敦美; 菊池, 春人; 村田, 満; 松本, 秀男

    2015-01-01

    To evaluate the association of serum BDNF concentration with high-intensity interval training, 12 healthy male volunteers, aged 28-48 years, completed 16-week high-intensity interval training (HIIT) using ergometer...

  2. Leveraging Microscience to Manipulate Laser-Plasma Interactions at Relativistic Intensities

    Science.gov (United States)

    Snyder, Joseph

    This thesis presents experimental and computational studies of a high intensity, ultra-short pulse laser incident on a hollow, micron-scale, cylindrical structure we have termed the Micro-tube Plasma (MTP) lens. The computational studies, performed using three-dimensional particle-in-cell (PIC) simulations, show that Fresnel diffraction and plasma guiding from the cylindrical structure lead to a redistribution of the incident laser intensity, resulting in a smaller focal spot, and as such, an increase in the laser intensity. The intensity enhancement inside the MTP lens occurs in three distinct regimes which are dictated by the pulse intensity. Crucially, as the pulse intensity becomes highly relativistic, there is a monatomic increase in the intensification factor with increasing intensity. The in-tube intensity distribution is studied to characterize the peak intensification and a method for averaging the in-tube intensity gives insight into the intensification lifetime. These complementary characterizations lead to a deeper understanding of intensification within the MTP lens. The effects of varying the dimensions of the cylindrical structure are described and this study provides optimized structure parameters for increasing the in-tube pulse intensity based on currently available laser technology. By coupling the MTP lens to a traditional flat interface, simulations indicate we can increase the peak and averaged intensity at the interface. This leads to enhancement of other phenomena, such as hole-boring ion acceleration. Additionally, the inclusion of a MTP lens enhances target normal sheath acceleration (TNSA) of rear surface ions. By tailoring the MTP lens, we achieve a simulated maximum proton energy that is 3.5 times higher than the energy from a traditional flat interface. An experiment to demonstrate the feasibility of these structures was performed at the Scarlet Laser Facility at The Ohio State University. Using a 300 microm long, 5 microm inner

  3. Production of High-Intensity, Highly Charged Ions

    CERN Document Server

    Gammino, S.

    2013-12-16

    In the past three decades, the development of nuclear physics facilities for fundamental and applied science purposes has required an increasing current of multicharged ion beams. Multiple ionization implies the formation of dense and energetic plasmas, which, in turn, requires specific plasma trapping configurations. Two types of ion source have been able to produce very high charge states in a reliable and reproducible way: electron beam ion sources (EBIS) and electron cyclotron resonance ion sources (ECRIS). Multiple ionization is also obtained in laser-generated plasmas (laser ion sources (LIS)), where the high-energy electrons and the extremely high electron density allow step-by-step ionization, but the reproducibility is poor. This chapter discusses the atomic physics background at the basis of the production of highly charged ions and describes the scientific and technological features of the most advanced ion sources. Particular attention is paid to ECRIS and the latest developments, since they now r...

  4. 78 FR 13566 - Energy Conservation Program for High-Intensity Discharge Lamps: Public Meeting and Availability...

    Science.gov (United States)

    2013-02-28

    ... Part 431 RIN 1904-AC36 Energy Conservation Program for High-Intensity Discharge Lamps: Public Meeting... conservation standards for high-intensity discharge (HID) lamps. The meeting will cover the analytical... High-Intensity Discharge Lamps, EERE-2010-BT-STD-0043 and/or RIN 1904-AC36, 1000 Independence Avenue SW...

  5. High-intensity focused ultrasound ablation around the tubing.

    Science.gov (United States)

    Siu, Jun Yang; Liu, Chenhui; Zhou, Yufeng

    2017-01-01

    High-intensity focused ultrasound (HIFU) has been emerging as an effective and noninvasive modality in cancer treatment with very promising clinical results. However, a small vessel in the focal region could be ruptured, which is an important concern for the safety of HIFU ablation. In this study, lesion formation in the polyacrylamide gel phantom embedded with different tubing (inner diameters of 0.76 mm and 3 mm) at varied flow speeds (17-339 cm/s) by HIFU ablation was photographically recorded. Produced lesions have decreased length (~30%) but slightly increased width (~6%) in comparison to that without the embedded tubing. Meanwhile, bubble activities during the exposures were measured by passive cavitation detection (PCD) at the varied pulse repetition frequency (PRF, 10-30 Hz) and duty cycle (DC, 10%-20%) of the HIFU bursts. High DC and low flow speed were found to produce stronger bubble cavitation whereas no significant influence of the PRF. In addition, high-speed photography illustrated that the rupture of tubing was produced consistently after the first HIFU burst within 20 ms and then multiple bubbles would penetrate into the intraluminal space of tubing through the rupture site by the acoustic radiation force. Alignment of HIFU focus to the anterior surface, middle, and posterior surface of tubing led to different characteristics of vessel rupture and bubble introduction. In summary, HIFU-induced vessel rupture is possible as shown in this phantom study; produced lesion sizes and shapes are dependent on the focus alignment to the tubing, flow speed, and tubing properties; and bubble cavitation and the formation liquid jet may be one of the major mechanisms of tubing rupture as shown in the high-speed photography.

  6. Inelastic scattering in condensed matter with high intensity Moessbauer radiation

    Energy Technology Data Exchange (ETDEWEB)

    Yelon, W.B.; Schupp, G.

    1990-10-01

    We give a progress report for the work which has been carried out in the last three years with DOE support. A facility for high-intensity Moessbauer scattering is now fully operational at the University of Missouri Research Reactor (MURR) as well as facility at Purdue, using special isotopes produced at MURR. High precision, fundamental Moessbauer effect studies have been carried out using scattering to filter the unwanted radiation. These have led to a new Fourier transform method for describing Moessbauer effect (ME) lineshape and a direct method of fitting ME data to the convolution integral. These methods allow complete correction for source resonance self absorption (SRSA) and the accurate representation of interference effects that add an asymmetric component to the ME lines. We have begun applying these techniques to attenuated ME sources whose central peak has been attenuated by stationary resonant absorbers, to more precisely determine interference parameters and line-shape behavior in the resonance asymptotic region. This analysis is important to both the fundamental ME studies and to scattering studies for which a deconvolution is essential for extracting the correct recoilless fractions and interference parameters. A number of scattering studies have been successfully carried out including a study of the thermal diffuse scattering in Si, which led to an analysis of the resolution function for gamma-ray scattering. Also studied was the anharmonic motion in Na and the satellite reflection Debye-Waller factor in TaS{sub 2}, which indicate phason rather than phonon behavior. We have begun quasielastic diffusion studies in viscous liquids and current results are summarized. These advances, coupled to our improvements in MIcrofoil Conversion Electron spectroscopy lay the foundation for the proposed research outlined in this request for a three-year renewal of DOE support.

  7. Gamma scattering in condensed matter with high intensity Moessbauer radiation

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    We give a progress report for the work which has been carried out in the last three years with DOE support. A facility for high-intensity Moessbauer scattering is now fully operational at the University of Missouri Research Reactor (MURR) as well as a facility at Purdue, using special isotopes produced at MURR. High precision, fundamental Moessbauer effect studies have been carried out using scattering to filter the unwanted radiation. These have led to a new Fourier transform method for describing Moessbauer effect (ME) lineshape and a direct method of fitting ME data to the convolution integral. These methods allow complete correction for source resonance self absorption (SRSA) and the accurate representation of interference effects that add an asymmetric component to the ME lines. We have begun applying these techniques to attenuated ME sources whose central peak has been attenuated by stationary resonant absorbers, to more precisely determine interference parameters and line-shape behavior in the resonance asymptotic region. This analysis is important to both the fundamental ME studies and to scattering studies for which a deconvolution is essential for extracting the correct recoilless fractions and interference parameters. A number of scattering studies have been successfully carried out including a study of the thermal diffuse scattering in Si, which led to an analysis of the resolution function for gamma-ray scattering. Also studied was the anharmonic motion in Na and the satellite reflection Debye-Waller factor in TaS{sub 2}, which indicate phason rather than phonon behavior. We have begun quasielastic diffusion studies in viscous liquids and current results are summarized. These advances, coupled to our improvements in MIcrofoil Conversion Electron spectroscopy lay the foundation for the proposed research outlined in this request for a three-year renewal of DOE support.

  8. Effects of high-intensity interval training on canoeing performance.

    Science.gov (United States)

    Yang, Ming-Ta; Lee, Mien-Mien; Hsu, Shu-Ching; Chan, Kuei-Hui

    2017-08-01

    The purpose of this study was to compare the effects of high-intensity interval training (HIIT) and moderate-intensity continuous training (MICT) utilizing a canoeing ergometer on endurance determinants, as well as aerobic and anaerobic performances among flat-water canoeists. Fourteen well-trained male flat-water canoeists were divided into an HIIT group or an MICT group. All subjects performed a continuous graded exercise test (GXT) and three fixed-distance (200, 500, and 1000 m) performance tests on a canoeing ergometer to determine canoeing economy, peak oxygen uptake (VO2peak), and power at VO2peak, and to calculate the critical velocity (CV) and anaerobic work capacity before and after the training programmes. The training programme involved training on a canoeing ergometer three times per week for four weeks. HIIT consisted of seven 2 min canoeing bouts at an intensity of 90% VO2peak separated by 1 min of rest. The MICT group was trained at an intensity of 65% VO2peak continuously for 20 min. After four weeks of training, performance in the 200-m distance test and the power at VO2peak significantly improved in the HIIT group; performance in the 500 m and 1000 m distances and CV significantly improved in the MICT group. However, all variables were not significantly different between groups. It is concluded that HIIT for four weeks is an effective training strategy for improvement of short-distance canoeing performance. In contrast, MICT improves middle-distance canoeing performances and aerobic capacity.

  9. Energy compensation after sprint- and high-intensity interval training.

    Science.gov (United States)

    Schubert, Matthew M; Palumbo, Elyse; Seay, Rebekah F; Spain, Katie K; Clarke, Holly E

    2017-01-01

    Many individuals lose less weight than expected in response to exercise interventions when considering the increased energy expenditure of exercise (ExEE). This is due to energy compensation in response to ExEE, which may include increases in energy intake (EI) and decreases in non-exercise physical activity (NEPA). We examined the degree of energy compensation in healthy young men and women in response to interval training. Data were examined from a prior study in which 24 participants (mean age, BMI, & VO2max = 28 yrs, 27.7 kg•m-2, and 32 mL∙kg-1∙min-1) completed either 4 weeks of sprint-interval training or high-intensity interval training. Energy compensation was calculated from changes in body composition (air displacement plethysmography) and exercise energy expenditure was calculated from mean heart rate based on the heart rate-VO2 relationship. Differences between high (≥ 100%) and low (high levels of energy compensation gained fat mass, lost fat-free mass, and had lower change scores for VO2max and NEPA. Linear regression results indicated that lower levels of energy compensation were associated with increases in ΔVO2max (p interval training. In agreement with prior work, increases in ΔVO2max and ΔNEPA were associated with lower energy compensation. Future studies should focus on identifying if a dose-response relationship for energy compensation exists in response to interval training, and what underlying mechanisms and participant traits contribute to the large variation between individuals.

  10. High-Intensity Events in International Women's Team Handball Matches.

    Science.gov (United States)

    Luteberget, Live S; Spencer, Matt

    2017-01-01

    International women's team handball is a physically demanding sport and is intermittent in nature. The aim of the study was to profile high-intensity events (HIEs) in international women's team handball matches with regard to playing positions. Twenty female national-team handball players were equipped with inertial movement units (OptimEye S5, Catapult Sports, Australia) in 9 official international matches. Players were categorized in 4 different playing positions: backs, wings, pivots, and goalkeepers (GKs). PlayerLoad™, accelerations (Acc), changes of direction (CoD), decelerations (Dec), and the sum of the latter 3, HIEs, were extracted from raw-data files using the manufacturer's software. All Acc, Dec, CoD, and HIEs >2.5 m/s were included. Data were log-transformed and differences were standardized for interpretation of magnitudes and reported with effect-size statistics. Mean numbers of events were 0.7 ± 0.4 Acc/min, 2.3 ± 0.9 Dec/min, and 1.0 ± 0.4 CoD/min. Substantial differences between playing positions, ranging from small to very large, were found in the 3 parameters. Backs showed a most likely greater frequency for HIE/min (5.0 ± 1.1 HIE/min) than all other playing positions. Differences between playing positions were also apparent in PlayerLoad/min. HIEs in international women's team handball are position specific, and the overall intensity depends on the positional role within a team. Specific HIE and intensity profiles from match play provide useful information for a better understanding of the overall game demands and for each playing position.

  11. Glass Strengthening via High-Intensity Plasma-Arc Heating

    Energy Technology Data Exchange (ETDEWEB)

    Wereszczak, Andrew A [ORNL; Harper, David C [ORNL; Duty, Chad E [ORNL; Patel, P [U.S. Army research Laboratory, Adelphi, MD

    2010-01-01

    The use of a high-intensity plasma-arc lamp was used to irradiate the surface of soda-lime silicate glass tiles to determine if an increase in strength could be achieved. The lamp had a power density of 3500 W/cm2, a processing area of 1 cm x 10 cm, irradiated near-infrared heating at a wavelength between 0.2 1.4 m, and was controlled to unidirectionally sweep across 50-mm-square tiles at a constant speed of 8 mm/s. Ring-on-ring (RoR) equibiaxial flexure and 4 pt uni-directional flexure testings of entire tiles were used to measure and compare failure stress distributions of treated and untreated glass. Even with non-optimized processing conditions, RoR failure stress increased by approximately 25% and the 4 pt bend failure stress increased by approximately 65%. Strengthening was due to a fire-polishing-like mechanism. The arc-lamp heat-treatment caused the location of the strength-limiting flaws in the 4-pt-bend tiles to change; namely, failure initiation occurred on the gage section surface for the treated glass whereas it occurred at a gage section edge for the untreated. Arc-lamp heat-treatment is attractive not only because it provides strengthening, but because it can (non-contact) process large amounts of glass quickly and inexpensively, and is a process that either a glass manufacturer or end-user can readily employ.

  12. Compliance with High-Intensity Radiated Fields Regulations - Emitter's Perspective

    Science.gov (United States)

    Statman, Joseph; Jamnejad, Vahraz; Nguyen, Lee

    2012-01-01

    NASA's Deep Space Network (DSN) uses high-power transmitters on its large antennas to communicate with spacecraft of NASA and its partner agencies. The prime reflectors of the DSN antennas are parabolic, at 34m and 70m in diameter. The DSN transmitters radiate Continuous Wave (CW) signals at 20 kW - 500 kW at X-band and S-band frequencies. The combination of antenna reflector size and high frequency results in a very narrow beam with extensive oscillating near-field pattern. Another unique feature of the DSN antennas is that they (and the radiated beam) move mostly at very slow sidereal rate, essentially identical in magnitude and at the opposite direction of Earth rotation.The DSN is in the process of revamping its documentation to provide analysis of the High Intensity Radiation Fields (HIRF) environment resulting from radio frequency radiation from DSN antennas for comparison to FAA regulations regarding certification of HIRF protection as outlined in the FAA regulations on HIRF protection for aircraft electrical and electronic systems (Title 14, Code of Federal Regulations (14 CFR) [section sign][section sign] 23.1308, 25.1317, 27.1317, and 29.1317).This paper presents work done at JPL, in consultation with the FAA. The work includes analysis of the radiated field structure created by the unique DSN emitters (combination of transmitters and antennas) and comparing it to the fields defined in the environments in the FAA regulations. The paper identifies areas that required special attention, including the implications of the very narrow beam of the DSN emitters and the sidereal rate motion. The paper derives the maximum emitter power allowed without mitigation and the mitigation zones, where required.Finally, the paper presents summary of the results of the analyses of the DSN emitters and the resulting DSN process documentation.

  13. Outcomes of exertional rhabdomyolysis following high-intensity resistance training.

    Science.gov (United States)

    Huynh, A; Leong, K; Jones, N; Crump, N; Russell, D; Anderson, M; Steinfort, D; Johnson, D F

    2016-05-01

    High-intensity resistance training (HIRT) programmes are increasingly popular amongst personal trainers and those attending gymnasiums. We report the experience of exertional rhabdomyolysis (ER) at two tertiary hospitals in Melbourne, Australia. To compare the clinical outcomes of ER with other causes of rhabdomyolysis. Retrospective cross-sectional study of patients presenting with a serum creatine kinase (CK) of greater than 25 000 units/L from 1 September 2013 to 31 August 2014 at two tertiary referral hospitals in Melbourne, Australia. Records were examined to identify care measures implemented during hospital stay, clinical outcomes during admission and on subsequent follow up. Thirty four cases of rhabdomyolysis with a CK of greater than 25 000 units/L (normal range: 20-180 units/L) were identified during the 12-month study period. Twelve of the 34 cases (35%) had ER with 10 of 12 related to HIRT. No acute kidney injury, intensive care admission or death were seen among those with ER. All cases were managed conservatively, with 11 admitted and 9 receiving intravenous fluids only. In contrast, patients with rhabdomyolysis from other causes experienced significantly higher rates of intensive care admission (64%, P = 0.0002), acute kidney injury (82%, P = 0.0001) and death (27%, P = 0.069). ER resulting from HIRT appears to have a benign course compared with rhabdomyolysis of other aetiologies in patients with a serum CK greater than 25 000 units/L. Conservative management of ER appears to be adequate, although this requires confirmation in future prospective studies. © 2016 Royal Australasian College of Physicians.

  14. Development of a High Intensity Focused Ultrasound (HIFU) Hydrophone System

    Science.gov (United States)

    Schafer, Mark E.; Gessert, James

    2009-04-01

    The growing clinical use of High Intensity Focused Ultrasound (HIFU) has driven a need for reliable, reproducible measurements of HIFU acoustic fields. We have previously presented data on a reflective scatterer approach, incorporating several novel features for improved bandwidth, reliability, and reproducibility [Proc. 2005 IEEE Ultrasonics Symposium, 1739-1742]. We now report on several design improvements which have increase the signal to noise ratio of the system, and potentially reduced the cost of implementation. For the scattering element, we now use an artificial sapphire material to provide a more uniform radiating surface. The receiver is a segmented, truncated spherical structure with a 10 cm radius; the scattering element is positioned at the center of the sphere. The receiver is made from 25 micron thick, biaxially stretched PVDF, with a Pt-Au electrode on the front surface. In the new design, a specialized backing material provides the stiffness required to maintain structural stability, while at the same time providing both electrical shielding and ultrasonic absorption. Compared with the previous version, the new receiver design has improved the noise performance by 8-12 dB; the new scattering sphere has reduced the scattering loss by another 14 dB, producing an effective sensitivity of -298 dB re 1 microVolt/Pa. The design trade-off still involves receiver sensitivity with effective spot size, and signal distortion from the scatter structure. However, the reduced cost and improved repeatability of the new scatter approach makes the overall design more robust for routine waveform measurements of HIFU systems.

  15. Precise femtosecond laser ablation of dental hard tissue: preliminary investigation on adequate laser parameters

    Science.gov (United States)

    Hikov, Todor; Pecheva, Emilia; Montgomery, Paul; Antoni, Frederic; Leong-Hoi, Audrey; Petrov, Todor

    2017-01-01

    This work aims at evaluating the possibility of introducing state-of-the-art commercial femtosecond laser system in restorative dentistry by maintaining well-known benefits of lasers for caries removal, but also in overcoming disadvantages such as thermal damage of irradiated substrate. Femtosecond ablation of dental hard tissue is investigated by changing the irradiation parameters (pulsed laser energy, scanning speed and pulse repetition rate), assessed for enamel and dentin. The femtosecond laser system used in this work may be suitable for cavity preparation in dentin and enamel, due to the expected effective ablation and low temperature increase when using ultra short laser pulses. If adequate laser parameters are selected, this system seems to be promising for promoting a laser-assisted, minimally invasive approach in restorative dentistry.

  16. Investigation of therapy improvement using real-time photoacoustic imaging guided high intensity focused ultrasound

    Science.gov (United States)

    Cui, Huizhong

    There are a lot of risks in cancer treatment by invasive surgery, such as bleeding, wound infection, and long recovery time, etc. Therefore, there is great need for minimally- or non-invasive treatment. High intensity focused ultrasound (HIFU) is a rapidly growing and truly non-invasive technology. It has been widely used in therapeutic applications, such as rapid tissue heating and tissue ablation. With proper imaging guidance, HIFU treatment can be performed totally noninvasively. Currently, ultrasound imaging-guided HIFU has been extensively studied. However, ultrasound imaging guidance is less precise because of the relatively low imaging contrast, sensitivity, and specificity for noninvasive detection. In this study, we employed photoacoustic imaging (PAI) technique, which has been developed a novel promising imaging technique for early cancer detection, to guide HIFU treatment. The goal of this study is to investigate the feasibility of PAI to guide, monitor in real time and enhance the HIFU therapy. In this dissertation, as the first step, the integrated PAI and HIFU system had been shown to have the feasibility to guide HIFU both ex vivo and in vivo. Then, the system was improved and developed to a real-time PAI-guided HIFU system. It is demonstrated that the sensitivity of PA detection for HIFU lesion is very high and the saturation of PA signals can be used as the indicator for tissue coagulation. During the temperature measurement using this system, laser-enhanced HIFU heating was found. Thus, we further investigated the laser enhanced technique in both HIFU heating and pulsed HIFU thrombolysis. In the HIFU therapy, laser light was employed to illuminate the sample concurrently with HIFU radiation. The resulting cavitation was detected with a passive cavitation detector. We demonstrated that concurrent light illumination during HIFU has the potential to significantly enhance HIFU by reducing cavitation threshold.

  17. MODIFICATION OF SILICON ABSORPTIVITY UNDER FEMTOSECOND LASER PULSE

    Directory of Open Access Journals (Sweden)

    I. V. Guk,

    2013-05-01

    Full Text Available The article deals with theoreticalmodeling results of the combined influence of nonlinear absorptivity and absorption coefficient on the spatial and temporal distribution of the electron-hole plasma and the dynamics of the specific absorption flux in silicon under femtosecond laser pulse. It is shown thatincreased absorption of the hot electron gas makes the main contribution to the change in specific absorption flux. Obtained results were compared with the known views about the polariton mechanism,which is usedfor the interpretation of femtosecond laser silicon microstructuring. There aredemonstratedThe need to consider absorption capacity dynamics in the regimes assessment of ultra short laser semiconductor processing.

  18. Energy compensation after sprint- and high-intensity interval training.

    Directory of Open Access Journals (Sweden)

    Matthew M Schubert

    Full Text Available Many individuals lose less weight than expected in response to exercise interventions when considering the increased energy expenditure of exercise (ExEE. This is due to energy compensation in response to ExEE, which may include increases in energy intake (EI and decreases in non-exercise physical activity (NEPA. We examined the degree of energy compensation in healthy young men and women in response to interval training.Data were examined from a prior study in which 24 participants (mean age, BMI, & VO2max = 28 yrs, 27.7 kg•m-2, and 32 mL∙kg-1∙min-1 completed either 4 weeks of sprint-interval training or high-intensity interval training. Energy compensation was calculated from changes in body composition (air displacement plethysmography and exercise energy expenditure was calculated from mean heart rate based on the heart rate-VO2 relationship. Differences between high (≥ 100% and low (< 100% levels of energy compensation were assessed. Linear regressions were utilized to determine associations between energy compensation and ΔVO2max, ΔEI, ΔNEPA, and Δresting metabolic rate.Very large individual differences in energy compensation were noted. In comparison to individuals with low levels of compensation, individuals with high levels of energy compensation gained fat mass, lost fat-free mass, and had lower change scores for VO2max and NEPA. Linear regression results indicated that lower levels of energy compensation were associated with increases in ΔVO2max (p < 0.001 and ΔNEPA (p < 0.001.Considerable variation exists in response to short-term, low dose interval training. In agreement with prior work, increases in ΔVO2max and ΔNEPA were associated with lower energy compensation. Future studies should focus on identifying if a dose-response relationship for energy compensation exists in response to interval training, and what underlying mechanisms and participant traits contribute to the large variation between individuals.

  19. High-intensity re-warm-ups enhance soccer performance.

    Science.gov (United States)

    Zois, J; Bishop, D; Fairweather, I; Ball, K; Aughey, R J

    2013-09-01

    The effects of high-intensity, short-duration, re-warm-ups on team-sport-related performance were investigated. In a randomised, cross-over study, participants performed 2×26-min periods of an intermittent activity protocol (IAP) on a non-motorized treadmill, interspersed by 15-min of passive recovery (CON); 3-min small-sided game (SSG); or a 5RM leg-press. Measures included counter-movement jump, repeated-sprint, the Loughborough soccer passing test (LSPT), blood lactate concentration, heart-rate, and perceptual measures. Data were analyzed using effect size (90% confidence intervals), and percentage change; determining magnitudes of effects. A 5RM re-warm-up improved flight-time to contraction-time ratio when compared to SSG (9.8%, ES; 0.5±0.3) and CON (ES: 9.4%, 0.7±0.5) re-warm-ups, remaining higher following the second IAP (8.8%, ES; 0.5±0.3 and 10.2%, ES; 0.6±0.6, respectively). Relative-maximum rate-of-force development was greater in the 5RM condition following the second IAP compared to SSG (29.3%, ES; 0.7±0.5) and CON (16.2%, ES; 0.6±0.6). Repeated-sprint ability during the second IAP improved in the 5RM re-warm-up; peak velocity, mean velocity, and acceleration were 4, 3, and 18% greater, respectively. Within groups, the SSG re-warm-up improved LSPT performance post-intervention; 6.4% (ES: 0.6±0.8) and following the second IAP 6.2% (ES: 0.6±0.6), compared to pre-intervention. A 5RM leg-press re-warm-up improved physical performance, while a SSG re-warm-up enhanced skill execution following standardized intermittent exercise. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Strong field laser physics

    CERN Document Server

    2008-01-01

    Since the invention of the laser in the 1960s, people have strived to reach higher intensities and shorter pulse durations. High intensities and ultrashort pulse durations are intimately related. Recent developments have shown that high intensity lasers also open the way to realize pulses with the shortest durations to date, giving birth to the field of attosecond science (1 asec = 10-18s). This book is about high-intensity lasers and their applications. The goal is to give an up to date introduction to the technology behind these laser systems and to the broad range of intense laser applications. These applications include AMO (atomic molecular and optical) physics, x-ray science, attosecond science, plasma physics and particle acceleration, condensed matter science and laser micromachining, and finally even high-energy physics.

  1. A simplified physical model of pressure wave dynamics and acoustic wave generation induced by laser absorption in the retina.

    Science.gov (United States)

    Till, S J; Milsom, P K; Rowlands, G

    2004-07-01

    Shock waves have been proposed in the literature as a mechanism for retinal damage induced by ultra-short laser pulses. For a spherical absorber, we derive a set of linear equations describing the propagation of pressure waves. We show that the formation of shock fronts is due to the form of the absorber rather than the inclusion of nonlinear terms in the equations. The analytical technique used avoids the need for a Laplace transform approach and is easily applied to other absorber profiles. Our analysis suggests that the 'soft' nature of the membrane surrounding retinal melanosomes precludes shock waves as a mechanism for the retinal damage induced by ultra-short pulse lasers. The quantitative estimates of the pressure gradients induced by laser absorption which are made possible by this work, together with detailed meso-scale or molecular modelling, will allow alternative damage mechanisms to be identified.

  2. Gold nanoparticle nucleated cavitation for enhanced high intensity focused ultrasound therapy

    Science.gov (United States)

    McLaughlan, J. R.; Cowell, D. M. J.; Freear, S.

    2018-01-01

    High intensity focused ultrasound (HIFU) or focused ultrasound surgery is a non-invasive technique for the treatment of cancerous tissue, which is limited by difficulties in getting real-time feedback on treatment progress and long treatment durations. The formation and activity of acoustic cavitation, specifically inertial cavitation, during HIFU exposures has been demonstrated to enhance heating rates. However, without the introduction of external nuclei its formation an activity can be unpredictable, and potentially counter-productive. In this study, a combination of pulse laser illumination (839 nm), HIFU exposures (3.3 MHz) and plasmonic gold nanorods (AuNR) was demonstrated as a new approach for the guidance and enhancement of HIFU treatments. For imaging, short duration HIFU pulses (10 μs) demonstrated broadband acoustic emissions from AuNR nucleated cavitation with a signal-to-noise ranging from 5–35 dB for peak negative pressures between 1.19–3.19  ±  0.01 MPa. In the absence of either AuNR or laser illumination these emissions were either not present or lower in magnitude (e.g. 5 dB for 3.19 MPa). Continuous wave (CW) HIFU exposures for 15 s, were then used to generate thermal lesions for peak negative pressures from 0.2–2.71  ±  0.01 MPa at a fluence of 3.4 mJ cm-2 . Inertial cavitation dose (ICD) was monitored during all CW exposures, where exposures combined with both laser illumination and AuNRs resulted in the highest level of detectable emissions. This parameter was integrated over the entire exposure to give a metric to compare with measured thermal lesion area, where it was found that a minimum total ICD of 1.5 × 103 a.u. was correlated with the formation of thermal lesions in gel phantoms. Furthermore, lesion area (mm2) was increased for equivalent exposures without either AuNRs or laser illumination. Once combined with cancer targeting AuNRs this approach could allow for the future theranostic use of HIFU

  3. Laser structuring for control of coupling between THz light and phonon modes

    CERN Document Server

    Wang, X W; Balcytis, A; Kasalynas, I; Jakstas, V; Janonis, V; Venckevicius, R; Buividas, R; Appadoo, D; Valusis, G; Juodkazis, S

    2016-01-01

    Modification of surface and volume of sapphire is shown to affect reflected and transmitted light at THz spectral range. Structural modifications were made using ultra-short 230 fs laser pulses at 1030 nm and 257.5 nm wavelengths forming surface ripples of ~250 nm and 60 nm period, respectively. Softening of the transverse optical phonon TO1 mode due to disorder was the most pronounced in reflection from laser ablated surface. It is shown that sub-surface periodic patterns of laser damage sites have also modified reflection spectrum due to coupling of THz radiation with phonons. Application potential of laser structuring and disordering for phononic engineering is discussed.

  4. Max Tech and Beyond: High-Intensity Discharge Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Scholand, Michael

    2012-04-01

    High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. With the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable

  5. Nakagami imaging for detecting thermal lesions induced by high-intensity focused ultrasound in tissue.

    Science.gov (United States)

    Rangraz, Parisa; Behnam, Hamid; Tavakkoli, Jahan

    2014-01-01

    High-intensity focused ultrasound induces focalized tissue coagulation by increasing the tissue temperature in a tight focal region. Several methods have been proposed to monitor high-intensity focused ultrasound-induced thermal lesions. Currently, ultrasound imaging techniques that are clinically used for monitoring high-intensity focused ultrasound treatment are standard pulse-echo B-mode ultrasound imaging, ultrasound temperature estimation, and elastography-based methods. On the contrary, the efficacy of two-dimensional Nakagami parametric imaging based on the distribution of the ultrasound backscattered signals to quantify properties of soft tissue has recently been evaluated. In this study, ultrasound radio frequency echo signals from ex vivo tissue samples were acquired before and after high-intensity focused ultrasound exposures and then their Nakagami parameter and scaling parameter of Nakagami distribution were estimated. These parameters were used to detect high-intensity focused ultrasound-induced thermal lesions. Also, the effects of changing the acoustic power of the high-intensity focused ultrasound transducer on the Nakagami parameters were studied. The results obtained suggest that the Nakagami distribution's scaling and Nakagami parameters can effectively be used to detect high-intensity focused ultrasound-induced thermal lesions in tissue ex vivo. These parameters can also be used to understand the degree of change in tissue caused by high-intensity focused ultrasound exposures, which could be interpreted as a measure of degree of variability in scatterer concentration in various parts of the high-intensity focused ultrasound lesion.

  6. Application of FEL technique for constructing high-intensity, monochromatic, polarized gamma-sources at storage rings

    Energy Technology Data Exchange (ETDEWEB)

    Saldin, E.L.; Schneidmiller, E.A.; Ulyanov, Yu.N. [Automatic Systems Corporation, Samara (Russian Federation)] [and others

    1995-12-31

    A possibility to construct high-intensity tunable monochromatic{gamma}-source at high energy storage rings is discussed. It is proposed to produce {gamma}-quanta by means of Compton backscattering of laser photons on electrons circulating in the storage. The laser light wavelength is chosen in such a way that after the scattering, the electron does not leave the separatrix. So as the probability of the scattering is rather small, energy oscillations are damped prior the next scattering. As a result, the proposed source can operate in {open_quotes}parasitic{close_quote} mode not interfering with the main mode of the storage ring operation. Analysis of parameters of existent storage rings (PETRA, ESRF, Spring-8, etc) shows that the laser light wavelength should be in infrared, {lambda}{approximately} 10 - 400 {mu}m, wavelength band. Installation at storage rings of tunable free-electron lasers with the peak and average output power {approximately} 10 MW and {approximately} 1 kW, respectively, will result in the intensity of the {gamma}-source up to {approximately} 10{sup 14}s{sup -1} with tunable {gamma}-quanta energy from several MeV up to several hundreds MeV. Such a {gamma}-source will reveal unique possibilities for precision investigations in nuclear physics.

  7. A "slingshot" laser-driven acceleration mechanism of plasma electrons

    CERN Document Server

    Fiore, Gaetano; Fedele, Renato

    2016-01-01

    We briefly report on the recently proposed [G. Fiore, R. Fedele, U. de Angelis, Phys. Plasmas 21 (2014), 113105], [G. Fiore, S. De Nicola, arXiv:1509.04656] electron acceleration mechanism named "slingshot effect": under suitable conditions the impact of an ultra-short and ultra-intense laser pulse against the surface of a low-density plasma is expected to cause the expulsion of a bunch of superficial electrons with high energy in the direction opposite to that of the pulse propagation; this is due to the interplay of the huge ponderomotive force, huge longitudinal field arising from charge separation, and the finite size of the laser spot.

  8. High-intensity training reduces CD8+ T-cell redistribution in response to exercise

    NARCIS (Netherlands)

    Witard, O.C.; Turner, J.E.; Jackman, S.R.; Tipton, K.D.; Jeukendrup, A.E.; Kies, A.K.; Bosch, J.A.

    2012-01-01

    Purpose: We examined whether exercise-induced lymphocytosis and lymphocytopenia are impaired with high-intensity training. Methods: Eight trained cyclists (V·O2max = 64.2 ± 6.5 mL·kg-1·min-1) undertook 1 wk of normal-intensity training and a second week of high-intensity training. On day 7 of each

  9. Enhancing Plasma Surface Modification using high Intensity and high Power Ultrasonic Acoustic Waves

    DEFF Research Database (Denmark)

    2010-01-01

    high intensity and high power acoustic waves (102) by at least one ultrasonic high intensity and high power acoustic wave generator (101 ), wherein the ultrasonic acoustic waves are directed to propagate towards said surface (314) of the object (100) so that a laminar boundary layer (313) of a gas...

  10. Effect of Short-Term, High-Intensity Exercise on Anaerobic Threshold in Women.

    Science.gov (United States)

    Evans, Blanche W.

    This study investigated the effects of a six-week, high-intensity cycling program on anaerobic threshold (AT) in ten women. Subjects trained four days a week using high-intensity interval-type cycle exercises. Workouts included six 4-minute intervals cycling at 85 percent maximal oxygen uptake (VO sub 2 max), separated by 3-minute intervals of…

  11. The influence of basketball dribbling on repeated high-intensity intermittent runs

    Directory of Open Access Journals (Sweden)

    Zhaowei Kong

    2015-12-01

    Conclusion: The results suggest that the Yo-Yo IE2 test could reflect the repeatability of high-intensity intermittent basketball dribbling performance, while dribbling skills may have different influences on high-intensity intermittent exercise capacity in adolescent players at different ages.

  12. Effect of high-intensity training on endothelial function in patients with cardiovascular and cerebrovascular disease

    DEFF Research Database (Denmark)

    Kolmos, Mia; Krawcyk, Rikke Steen; Kruuse, Christina

    2016-01-01

    was to gather current knowledge on the effects of high-intensity training versus moderate-intensity continuous exercise on endothelial function in cardiovascular and cerebrovascular patients. METHODS: A systematic review was performed in PubMed database, Embase and Cochrane libraries and on PEDro using...... the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies were restricted to cardiovascular and cerebrovascular patients, and healthy subjects as general reference. Interventions comprised of high-intensity training alone, high-intensity training compared to moderate-intensity......: A total of 20 studies were included in the review. Although there was great heterogenecity in design, population and exercise protocols, all studies found high-intensity training to be safe. High-intensity training was equal to moderate-intensity continuous exercise through improvement in endothelial...

  13. RF synchronized short pulse laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Fuwa, Yasuhiro, E-mail: fuwa@kyticr.kuicr.kyoto-u.ac.jp; Iwashita, Yoshihisa; Tongu, Hiromu; Inoue, Shunsuke; Hashida, Masaki; Sakabe, Shuji [Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011 (Japan); Okamura, Masahiro [Collider-Accelerator Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Yamazaki, Atsushi [Graduate School of Engineering, Nagoya University, Nagoya, Aichi 464-8603 (Japan)

    2016-02-15

    A laser ion source that produces shortly bunched ion beam is proposed. In this ion source, ions are extracted immediately after the generation of laser plasma by an ultra-short pulse laser before its diffusion. The ions can be injected into radio frequency (RF) accelerating bucket of a subsequent accelerator. As a proof-of-principle experiment of the ion source, a RF resonator is prepared and H{sub 2} gas was ionized by a short pulse laser in the RF electric field in the resonator. As a result, bunched ions with 1.2 mA peak current and 5 ns pulse length were observed at the exit of RF resonator by a probe.

  14. Underutilization of high-intensity statin therapy after hospitalization for coronary heart disease.

    Science.gov (United States)

    Rosenson, Robert S; Kent, Shia T; Brown, Todd M; Farkouh, Michael E; Levitan, Emily B; Yun, Huifeng; Sharma, Pradeep; Safford, Monika M; Kilgore, Meredith; Muntner, Paul; Bittner, Vera

    2015-01-27

    National guidelines recommend use of high-intensity statins after hospitalization for coronary heart disease (CHD) events. This study sought to estimate the proportion of Medicare beneficiaries filling prescriptions for high-intensity statins after hospital discharge for a CHD event and to analyze whether statin intensity before hospitalization is associated with statin intensity after discharge. We conducted a retrospective cohort study using a 5% random sample of Medicare beneficiaries between 65 and 74 years old. Beneficiaries were included in the analysis if they filled a statin prescription after a CHD event (myocardial infarction or coronary revascularization) in 2007, 2008, or 2009. High-intensity statins included atorvastatin 40 to 80 mg, rosuvastatin 20 to 40 mg, and simvastatin 80 mg. Among 8,762 Medicare beneficiaries filling a statin prescription after a CHD event, 27% of first post-discharge fills were for a high-intensity statin. The percent filling a high-intensity statin post-discharge was 23.1%, 9.4%, and 80.7%, for beneficiaries not taking statins pre-hospitalization, taking low/moderate-intensity statins, and taking high-intensity statins before their CHD event, respectively. Compared with beneficiaries not on statin therapy pre-hospitalization, multivariable adjusted risk ratios for filling a high-intensity statin were 4.01 (3.58-4.49) and 0.45 (0.40-0.52) for participants taking high-intensity and low/moderate-intensity statins before their CHD event, respectively. Only 11.5% of beneficiaries whose first post-discharge statin fill was for a low/moderate-intensity statin filled a high-intensity statin within 365 days of discharge. The majority of Medicare beneficiaries do not fill high-intensity statins after hospitalization for CHD. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. Distinct impacts of high intensity caregiving on caregivers' mental health and continuation of caregiving.

    Science.gov (United States)

    Kumagai, Narimasa

    2017-12-01

    Although high-intensity caregiving has been found to be associated with a greater prevalence of mental health problems, little is known about the specifics of this relationship. This study clarified the burden of informal caregivers quantitatively and provided policy implications for long-term care policies in countries with aging populations. Using data collected from a nationwide five-wave panel survey in Japan, I examined two causal relationships: (1) high-intensity caregiving and mental health of informal caregivers, and (2) high-intensity caregiving and continuation of caregiving. Considering the heterogeneity in high-intensity caregiving among informal caregivers, control function model which allows for heterogeneous treatment effects was used.This study uncovered three major findings. First, hours of caregiving was found to influence the continuation of high-intensity caregiving among non-working informal caregivers and irregular employees. Specifically, caregivers who experienced high-intensity caregiving (20-40 h) tended to continue with it to a greater degree than did caregivers who experienced ultra-high-intensity caregiving (40 h or more). Second, high-intensity caregiving was associated with worse mental health among non-working caregivers, but did not have any effect on the mental health of irregular employees. The control function model revealed that caregivers engaging in high-intensity caregiving who were moderately mentally healthy in the past tended to have serious mental illness currently. Third, non-working caregivers did not tend to continue high-intensity caregiving for more than three years, regardless of co-residential caregiving. This is because current high-intensity caregiving was not associated with the continuation of caregiving when I included high-intensity caregiving provided during the previous period in the regression. Overall, I noted distinct impacts of high-intensity caregiving on the mental health of informal caregivers and

  16. Acute Effects of High Intensity Focused Ultrasound on Blood Vessels In Vivo

    Science.gov (United States)

    Davis, Sara; Raymond, Jason; Church, Charles

    2006-05-01

    The objective was to conduct a parameter study to examine how High Intensity Focused Ultrasound (HIFU) acoustic variables such as frequency, power, pulse duration, and duty cycle affect vascular occlusion in intact arteries. We used the New Zealand rabbit ear model and varied the ultrasound parameters using a dose-escalation approach. In each experiment, the animal's central auricular artery was exposed to HIFU. Frequency (2.2-4.7 MHz), power (10-87 W applied electrical power), pulse duration (5-20s), and duty cycle (5-100%) were varied to determine the optimal conditions for reducing/stopping arterial blood flow. In each experiment, the HIFU applicator was mechanically positioned above the target vessel and blood flow was monitored before and after HIFU treatment using Ultrasound Doppler and Laser Doppler Velocimetry. Vessel damage was confirmed with post-treatment histology. Results show that higher frequencies (3.5 MHz and 4.7 MHz) yielded occlusion more often than the lower frequency transducer (2.2 MHz). The results for lower duty-cycle sonications revealed that occlusion could be achieved at a duty cycle as low as 60%. We conclude that for vessels with minimal adjacent connective tissue, such as in the rabbit ear, HIFU treatments delivered at lower frequencies are less effective than treatments delivered at higher frequencies. Additionally, although the majority of exposures to date have been made using continuous-wave ultrasound, our results suggest that it is possible to achieve favorable results using lower duty-cycle (pulsed) exposures.

  17. Multi-wavelength photoacoustic imaging for monitoring lesion formation during high-intensity focused ultrasound therapy

    Science.gov (United States)

    Wu, Xun; Sanders, Jean; Dundar, Murat; Oralkan, Ömer

    2017-03-01

    Photoacoustic imaging (PAI) can be used to monitor lesion formation during high-intensity focused ultrasound (HIFU) therapy because HIFU changes the optical absorption spectrum (OAS) of the tissue. However, in traditional PAI, the change could be too subtle to be observed either because the OAS does not change very significantly at the imaging wavelength or due to low signal-to-noise ratio in general. We propose a machine-learning-based method for lesion monitoring with multi-wavelength PAI (MWPAI), where PAI is repeated at a sequence of wavelengths and a stack of multi-wavelength photoacoustic (MWPA) images is acquired. Each pixel is represented by a vector and each element in the vector reflects the optical absorption at the corresponding wavelength. Based on the MWPA images, a classifier is trained to classify pixels into two categories: ablated and non-ablated. In our experiment, we create a lesion on a block of bovine tissue with a HIFU transducer, followed by MWPAI in the 690 nm to 950 nm wavelength range, with a step size of 5 nm. In the MWPA images, some of the ablated and non-ablated pixels are cropped and fed to a neural network (NN) as training examples. The NN is then applied to several groups of MWPA images and the results show that the lesions can be identified clearly. To apply MWPAI in/near real-time, sequential feature selection is performed and the number of wavelengths is decreased from 53 to 5 while retaining adequate performance. With a fast-switching tunable laser, the method can be implemented in/near real-time.

  18. Effects of laser polarization in the expansion of plasma waveguides

    Science.gov (United States)

    Lemos, N.; Grismayer, T.; Cardoso, L.; Geada, J.; Figueira, G.; Dias, J. M.

    2013-10-01

    We experimentally demonstrate that a column of hydrogen plasma generated by an ultra-short (sub-picosecond), moderate intensity (˜1015-16 W.cm-2) laser, radially expands at a higher velocity when using a circularly polarized laser beam instead of a linearly polarized beam. Interferometry shows that after 1 ns there is a clear shock structure formed, that can be approximated to a cylindrical blast wave. The shock velocity was measured for plasmas created with linearly and circularly polarized laser beams, indicating an approximately 20% higher velocity for plasmas generated with a circularly polarized laser beam, thus implying a higher plasma electron temperature. The heating mechanism was determined to be the Above Threshold Ionization effect. The calculated electrum energy spectrum for a circularly polarized laser beam was broader when compared to the one generated by a linearly polarized laser beam, leading to a higher plasma temperature.

  19. [Femtosecond laser for refractive corneal surgery: foundations, mode of action and clinical applications].

    Science.gov (United States)

    Mrochen, M; Donges, A; Korn, G

    2006-12-01

    Modern corneal laser surgery for the correction of optical errors of the eye requires a precise, reliable and reproducible creation of corneal lenticels (flaps). The use of ultra-short laser pulses with pulse durations of a few 100 femtoseconds (10(-13) s) allows for non-thermal cuts of ocular tissue. Mean flap thicknesses as small as 100 microm with a reproducibility of 10 microm (standard deviation) can be created by using mechano-optical adaptations through the eye. Thus, the femtosecond laser can be considered a good alternative approach with a safety in clinical use that is comparable with that of mechanical microkeratomes.

  20. Short-term effects of implemented high intensity shoulder elevation during computer work

    Directory of Open Access Journals (Sweden)

    Madeleine Pascal

    2009-08-01

    Full Text Available Abstract Background Work-site strength training sessions are shown effective to prevent and reduce neck-shoulder pain in computer workers, but difficult to integrate in normal working routines. A solution for avoiding neck-shoulder pain during computer work may be to implement high intensity voluntary contractions during the computer work. However, it is unknown how this may influence productivity, rate of perceived exertion (RPE as well as activity and rest of neck-shoulder muscles during computer work. The aim of this study was to investigate short-term effects of a high intensity contraction on productivity, RPE and upper trapezius activity and rest during computer work and a subsequent pause from computer work. Methods 18 female computer workers performed 2 sessions of 15 min standardized computer mouse work preceded by 1 min pause with and without prior high intensity contraction of shoulder elevation. RPE was reported, productivity (drawings per min measured, and bipolar surface electromyography (EMG recorded from the dominant upper trapezius during pauses and sessions of computer work. Repeated measure ANOVA with Bonferroni corrected post-hoc tests was applied for the statistical analyses. Results The main findings were that a high intensity shoulder elevation did not modify RPE, productivity or EMG activity of the upper trapezius during the subsequent pause and computer work. However, the high intensity contraction reduced the relative rest time of the uppermost (clavicular trapezius part during the subsequent pause from computer work (p Conclusion Since a preceding high intensity shoulder elevation did not impose a negative impact on perceived effort, productivity or upper trapezius activity during computer work, implementation of high intensity contraction during computer work to prevent neck-shoulder pain may be possible without affecting the working routines. However, the unexpected reduction in clavicular trapezius rest during a

  1. Lasers.

    Science.gov (United States)

    Passeron, T

    2012-12-01

    Lasers are a very effective approach for treating many hyperpigmented lesions. They are the gold standard treatment for actinic lentigos and dermal hypermelanocytosis, such as Ota nevus. Becker nevus, hyperpigmented mosaicisms, and lentigines can also be successfully treated with lasers, but they could be less effective and relapses can be observed. However, lasers cannot be proposed for all types of hyperpigmentation. Thus, freckles and café-au-lait macules should not be treated as the relapses are nearly constant. Due to its complex pathophysiology, melasma has a special place in hyperpigmented dermatoses. Q-switched lasers (using standard parameters or low fluency) should not be used because of consistent relapses and the high risk of post-inflammatory hyperpigmentation. Paradoxically, targeting the vascular component of the melasma lesion with lasers could have a beneficial effect. However, these results have yet to be confirmed. In all cases, a precise diagnosis of the type of hyperpigmentation is mandatory before any laser treatment, and the limits and the potential side effects of the treatment must be clearly explained to patients. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  2. [Lasers].

    Science.gov (United States)

    Passeron, T

    2012-11-01

    Lasers are a very effective approach for treating many hyperpigmented lesions. They are the gold standard treatment for actinic lentigos and dermal hypermelanocytosis, such as Ota nevus. Becker nevus, hyperpigmented mosaicisms, and lentigines can also be successfully treated with lasers, but they could be less effective and relapses can be observed. However, lasers cannot be proposed for all types of hyperpigmentation. Thus, freckles and café-au-lait macules should not be treated as the relapses are nearly constant. Due to its complex pathophysiology, melasma has a special place in hyperpigmented dermatoses. Q-switched lasers (using standard parameters or low fluency) should not be used because of consistent relapses and the high risk of post-inflammatory hyperpigmentation. Paradoxically, targeting the vascular component of the melasma lesion with lasers could have a beneficial effect. However, these results have yet to be confirmed. In all cases, a precise diagnosis of the type of hyperpigmentation is mandatory before any laser treatment, and the limits and the potential side effects of the treatment must be clearly explained to patients. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  3. Few-layer antimonene decorated microfiber: ultra-short pulse generation and all-optical thresholding with enhanced long term stability

    Science.gov (United States)

    Song, Yufeng; Liang, Zhiming; Jiang, Xiantao; Chen, Yunxiang; Li, Zhongjun; Lu, Lu; Ge, Yanqi; Wang, Ke; Zheng, Jilin; Lu, Shunbin; Ji, Jianhua; Zhang, Han

    2017-12-01

    Antimonene, a new type of mono/few-layer two-dimensional (2D) mono-elemental material purely consisting of antimony similar as graphene and phosphorene, has been theoretically predicted with excellent optical response and enhanced stability. Herein, we experimentally investigated the broadband nonlinear optical response of highly stable few-layer antimonene (FLA) by performing an open-aperture Z-scan laser measurement. Thanks to the direct bandgap and resonant absorption at the telecommunication band, we demonstrated the feasibility of FLA-decorated microfiber not only as an optical saturable absorber for ultrafast photonics operation, but also as a stable all-optical pulse thresholder that can effectively suppress the transmission noise, boost the signal-to-noise ratio (SNR), and reshape the deteriorated input signal. Our findings, as the first prototypic device of absorption of antimonene, might facilitate the development of antimonene-based optical communication technologies towards high stability and practical applications in the future.

  4. High-intensity intermittent swimming improves cardiovascular health status for women with mild hypertension

    DEFF Research Database (Denmark)

    Mohr, Magni; Nordsborg, Nikolai Baastrup; Lindenskov, Annika

    2014-01-01

    intermittent swimming is an effective training strategy to improve cardiovascular health and physical performance......To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n = 21; HIT), moderate-intensity (n = 21; MOD), and control groups (n = 20; CON). HIT...... in sedentary women with mild hypertension. Adaptations are similar with high- and moderate-intensity training, despite markedly less total time spent and distance covered in the high-intensity group....

  5. Red-detuned, high-intensity, short-duration sweet spot for impulsive X-ray Raman excitation in atoms

    CERN Document Server

    Ware, Matthew R; Haxton, Daniel J

    2016-01-01

    Impulsive X-ray Raman excitations of Lithium, Neon, and Sodium are calculated using the Multiconfiguration Time-Dependent Hartree-Fock method. Using linearly polarized laser pulses without chirp, we determine the optimum central frequency, intensity, and duration for maximum population transfer to valence excited states. We demonstrate the existence of two "sweet spots" for optimum population transfer, either of which, depending on the system, may be superior. The "red-detuned hypothesis" is the proposition that population transfer can be maximized by nonresonant Raman transitions, red-detuned below K-edge, because such detuning minimizes core-excited populations and ionization loss. We find that this hypothesis is verified in the case of Neon -- for Neon, the global optimum for population transfer occurs at high intensity (8 $\\times$ 10$^{19}$ W cm$^{-2}$), short duration (82as full-width-at-half-maximum), and 24eV red-detuned from the K-edge.

  6. Effect of high-intensity interval exercise on basal triglyceride metabolism in non-obese men

    National Research Council Canada - National Science Library

    Bellou, Elena; Magkos, Faidon; Kouka, Tonia; Bouchalaki, Eirini; Sklaveniti, Dimitra; Maraki, Maria; Tsekouras, Yiannis E; Panagiotakos, Demosthenes B; Kavouras, Stavros A; Sidossis, Labros S

    2013-01-01

    ..., but whether this applies to very low density lipoprotein (VLDL) metabolism is not known. We sought to examine the effect of a single bout of high-intensity interval aerobic exercise on basal VLDL-triglyceride (TG...

  7. Improved high-intensity microwave discharge lamp for atomic resonance absorption and fluorescence spectrometry.

    Science.gov (United States)

    Lifshitz, A; Skinner, G B; Wood, D R

    1978-09-01

    An unusually good combination of high intensity and narrow line has been achieved in a microwave discharge lamp by placing the optical window in the center of the microwave cavity. Construction details and performance characteristics are described.

  8. Spatiotemporal monitoring of high-intensity focused ultrasound therapy with passive acoustic mapping

    National Research Council Canada - National Science Library

    Jensen, Carl R; Ritchie, Robert W; Gyöngy, Miklós; Collin, James R T; Leslie, Tom; Coussios, Constantin-C

    2012-01-01

    To demonstrate feasibility of monitoring high-intensity focused ultrasound (HIFU) treatment with passive acoustic mapping of broadband and harmonic emissions reconstructed from filtered-channel radiofrequency data in ex vivo bovine tissue...

  9. Effect of high-intensity interval exercise on basal triglyceride metabolism in non-obese men

    National Research Council Canada - National Science Library

    Bellou, Elena; Magkos, Faidon; Kouka, Tonia; Bouchalaki, Eirini; Sklaveniti, Dimitra; Maraki, Maria; Tsekouras, Yiannis E; Panagiotakos, Demosthenes B; Kavouras, Stavros A; Sidossis, Labros S

    2013-01-01

    A single bout of high-intensity interval aerobic exercise has been shown to produce the same or greater metabolic benefits as continuous endurance exercise with considerably less energy expenditure...

  10. Short-term effects of implemented high intensity shoulder elevation during computer work

    DEFF Research Database (Denmark)

    Larsen, Mette K; Samani, Afshin; Madeleine, Pascal

    2009-01-01

    contractions during the computer work. However, it is unknown how this may influence productivity, rate of perceived exertion (RPE) as well as activity and rest of neck-shoulder muscles during computer work. The aim of this study was to investigate short-term effects of a high intensity contraction...... on productivity, RPE and upper trapezius activity and rest during computer work and a subsequent pause from computer work. METHODS: 18 female computer workers performed 2 sessions of 15 min standardized computer mouse work preceded by 1 min pause with and without prior high intensity contraction of shoulder....... RESULTS: The main findings were that a high intensity shoulder elevation did not modify RPE, productivity or EMG activity of the upper trapezius during the subsequent pause and computer work. However, the high intensity contraction reduced the relative rest time of the uppermost (clavicular) trapezius...

  11. High-intensity interval training in facioscapulohumeral muscular dystrophy type 1

    DEFF Research Database (Denmark)

    Andersen, Grete; Heje, Karen; Buch, Astrid Emilie

    2017-01-01

    Increasing evidence suggests that high-intensity training (HIT) is a time-efficient exercise strategy to improve fitness. HIT has never been explored in neuromuscular diseases, likely because it may seem counterintuitive. A single session of high-intensity exercise has been studied without signs...... fitness (3.3 ml O2/min/kg, CI 1.2-5.5, P training effect on other outcomes. Patients preferred HIT over strength and moderate-intensity aerobic training. It may seem...

  12. Negative beliefs about low back pain are associated with persistent high intensity low back pain.

    Science.gov (United States)

    Ng, Sin Ki; Cicuttini, Flavia M; Wang, Yuanyuan; Wluka, Anita E; Fitzgibbon, Bernadette; Urquhart, Donna M

    2017-08-01

    While previous cross-sectional studies have found that negative beliefs about low back pain are associated with pain intensity, the relationship between back beliefs and persistent low back pain is not well understood. This cohort study aimed to examine the role of back beliefs in persistent low back pain in community-based individuals. A hundred and ninety-two participants from a previous musculoskeletal health study were invited to take part in a two-year follow-up study. Beliefs about back pain were assessed by the Back Beliefs Questionnaire (BBQ) at baseline and low back pain intensity was measured by the Chronic Pain Grade Questionnaire at baseline and follow-up. Of the 150 respondents (78.1%), 16 (10.7%) reported persistent high intensity low back pain, 12 (8.0%) developed high intensity low back pain, in 16 (10.7%) their high intensity low back pain resolved and 106 (70.7%) experienced no high intensity low back pain. While participants were generally positive about low back pain (BBQ mean (SD) = 30.2 (6.4)), those with persistent high intensity pain reported greater negativity (BBQ mean (SD) = 22.6 (4.9)). Negative beliefs about back pain were associated with persistent high intensity low back pain after adjusting for confounders (M (SE) = 23.5 (1.6) vs. >30.1 (1.7), p back beliefs were associated with persistent high intensity low back pain over 2 years in community-based individuals. While further longitudinal studies are required, these findings suggest that targeting beliefs in programs designed to treat and prevent persistent high intensity low back pain may be important.

  13. Short-term effects of implemented high intensity shoulder elevation during computer work.

    Science.gov (United States)

    Larsen, Mette K; Samani, Afshin; Madeleine, Pascal; Olsen, Henrik B; Søgaard, Karen; Holtermann, Andreas

    2009-08-10

    Work-site strength training sessions are shown effective to prevent and reduce neck-shoulder pain in computer workers, but difficult to integrate in normal working routines. A solution for avoiding neck-shoulder pain during computer work may be to implement high intensity voluntary contractions during the computer work. However, it is unknown how this may influence productivity, rate of perceived exertion (RPE) as well as activity and rest of neck-shoulder muscles during computer work. The aim of this study was to investigate short-term effects of a high intensity contraction on productivity, RPE and upper trapezius activity and rest during computer work and a subsequent pause from computer work. 18 female computer workers performed 2 sessions of 15 min standardized computer mouse work preceded by 1 min pause with and without prior high intensity contraction of shoulder elevation. RPE was reported, productivity (drawings per min) measured, and bipolar surface electromyography (EMG) recorded from the dominant upper trapezius during pauses and sessions of computer work. Repeated measure ANOVA with Bonferroni corrected post-hoc tests was applied for the statistical analyses. The main findings were that a high intensity shoulder elevation did not modify RPE, productivity or EMG activity of the upper trapezius during the subsequent pause and computer work. However, the high intensity contraction reduced the relative rest time of the uppermost (clavicular) trapezius part during the subsequent pause from computer work (p shoulder elevation did not impose a negative impact on perceived effort, productivity or upper trapezius activity during computer work, implementation of high intensity contraction during computer work to prevent neck-shoulder pain may be possible without affecting the working routines. However, the unexpected reduction in clavicular trapezius rest during a pause with preceding high intensity contraction requires further investigation before high

  14. Controllable robust laser driven ion acceleration from near-critical density relativistic self-transparent plasma

    Science.gov (United States)

    Liu, Bin; Meyer-Ter-Vehn, Juergen; Ruhl, Hartmut

    2017-10-01

    We introduce an alternative approach for laser driven self-injected high quality ion acceleration. We call it ion wave breaking acceleration. It operates in relativistic self-transparent plasma for ultra-intense ultra-short laser pulses. Laser propagating in a transparent plasma excites an electron wave as well as an ion wave. When the ion wave breaks, a fraction of ions is self-injected into the positive part of the laser driven wake. This leads to a superior ion pulse with peaked energy spectra; in particular in realistic three-dimensional geometry, the injection occurs localized close to the laser axis producing highly directed bunches. A theory is developed to investigate the ion wave breaking dynamics. Three dimensional Particle-in-Cell simulations with pure-gaussian laser pulses and pre-expanded near-critical density plasma targets have been done to verify the theoretical results. It is shown that hundreds of MeV, easily controllable and manipulable, micron-scale size, highly collimated and quasi-mono-energetic ion beams can be produced by using ultra-intense ultra-short laser pulses with total laser energies less than 10 Joules. Such ion beams may find important applications in tumour therapy. B. Liu acknowledges support from the Alexander von Humboldt Foundation. B. Liu and H. Ruhl acknowledge supports from the Gauss Centre for Supercomputing (GCS), and the Cluster-of-Excellence Munich Centre for Advanced Photonics (MAP).

  15. Group velocity and pulse lengthening of mismatched laser pulses in plasma channels

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Carl; Benedetti, Carlo; Esarey, Eric; van Tilborg, Jeroen; Leemans, Wim

    2011-07-07

    Analytic solutions are presented to the non-paraxial wave equation describing an ultra-short, low-power, laser pulse propagating in aplasma channel. Expressions for the laser pulse centroid motion and laser group velocity are derived, valid for matched and mismatchedpropagation in a parabolic plasma channel, as well as in vacuum, for an arbitrary Laguerre-Gaussian laser mode. The group velocity of amismatched laser pulse, for which the laser spot size is strongly oscillating, is found to be independent of propagation distance andsignificantly less than that of a matched pulse. Laser pulse lengthening of a mismatched pulse owing to laser mode slippage isexamined and found to dominate over that due to dispersive pulse spreading for sufficiently long pulses. Analytic results are shown tobe in excellent agreement with numerical solutions of the full Maxwell equations coupled to the plasma response. Implications for plasmachannel diagnostics are discussed.

  16. Physics of short-wavelength-laser design

    Energy Technology Data Exchange (ETDEWEB)

    Hagelstein, P.L.

    1981-01-01

    The physics and design of vuv and soft x-ray lasers pumped by ICF class high intensity infrared laser drivers are described (for example, the SHIVA laser facility at LLNL). Laser design and physics issues are discussed in the case of a photoionization pumping scheme involving Ne II and line pumping schemes involving H-like and He-like neon.

  17. Laser printed nano-gratings: orientation and period peculiarities

    CERN Document Server

    Stankevič, Valdemar; Bragheri, Francesca; Wang, Xuewen; Gamaly, Eugene G; Osellame, Roberto; Juodkazis, Saulius

    2016-01-01

    Understanding of material behaviour at nanoscale under intense laser excitation is becoming critical for future application of nanotechnologies. Nanograting formation by linearly polarised ultra-short laser pulses has been studied systematically in fused silica for various pulse energies at 3D laser printing/writing conditions, typically used for the industrial fabrication of optical elements. The period of the nanogratings revealed a dependence on the orientation of the scanning direction. A tilt of the nanograting wave vector at a fixed laser polarisation was also observed. The mechanism responsible for this peculiar dependency of several features of the nanogratings on the writing direction is qualitatively explained by considering the heat transport flux in the presence of a linearly polarised electric field, rather than by temporal and spatial chirp of the laser beam. The confirmed vectorial nature of the light-matter interaction opens new control of material processing with nanoscale precision.

  18. Sequential Injection Chromatography with an Ultra-short Monolithic Column for the Low-Pressure Separation of α-Tocopherol and γ-Oryzanol in Vegetable Oils and Nutrition Supplements.

    Science.gov (United States)

    Thaithet, Sujitra; Kradtap Hartwell, Supaporn; Lapanantnoppakhun, Somchai

    2017-01-01

    A low-pressure separation procedure of α-tocopherol and γ-oryzanol was developed based on a sequential injection chromatography (SIC) system coupled with an ultra-short (5 mm) C-18 monolithic column, as a lower cost and more compact alternative to the HPLC system. A green sample preparation, dilution with a small amount of hexane followed by liquid-liquid extraction with 80% ethanol, was proposed. Very good separation resolution (Rs = 3.26), a satisfactory separation time (10 min) and a total run time including column equilibration (16 min) were achieved. The linear working range was found to be 0.4 - 40 μg with R2 being more than 0.99. The detection limits of both analytes were 0.28 μg with the repeatability within 5% RSD (n = 7). Quantitative analyses of the two analytes in vegetable oil and nutrition supplement samples, using the proposed SIC method, agree well with the results from HPLC.

  19. Transverse pump-probe microscopy of moving breakdown, filamentation and self-organized absorption in alkali aluminosilicate glass using ultrashort pulse laser.

    Science.gov (United States)

    Grossmann, Daniel; Reininghaus, Martin; Kalupka, Christian; Kumkar, Malte; Poprawe, Reinhart

    2016-10-03

    We present time and space resolved transverse pump-probe measurements of the free electron and defect generation induced by nonlinear absorption of ultra short pulsed laser radiation in unhardened Corning Gorilla glass. The applied setup exhibits a 100 fs probe pulse duration and an independent pump pulse duration up to 5 ps. Hence, our work comprises the absorption of ultra short pulsed laser radiation at a wavelength of 800 nm and pulse energies from 10 μJ to 50 μJ up to a delay of 6 ns. Our investigations reveal different absorption regimes like filamentation and moving breakdown as well as the formation of permanent modifications. Finally, the deposition of multiple pulses in the incubation regime is examined, observing a self-organizing absorption effect.

  20. High-Intensity Interval Training Interventions in Children and Adolescents: A Systematic Review.

    Science.gov (United States)

    Eddolls, William T B; McNarry, Melitta A; Stratton, Gareth; Winn, Charles O N; Mackintosh, Kelly A

    2017-11-01

    Whilst there is increasing interest in the efficacy of high-intensity interval training in children and adolescents as a time-effective method of eliciting health benefits, there remains little consensus within the literature regarding the most effective means for delivering a high-intensity interval training intervention. Given the global health issues surrounding childhood obesity and associated health implications, the identification of effective intervention strategies is imperative. The aim of this review was to examine high-intensity interval training as a means of influencing key health parameters and to elucidate the most effective high-intensity interval training protocol. Studies were included if they: (1) studied healthy children and/or adolescents (aged 5-18 years); (2) prescribed an intervention that was deemed high intensity; and (3) reported health-related outcome measures. A total of 2092 studies were initially retrieved from four databases. Studies that were deemed to meet the criteria were downloaded in their entirety and independently assessed for relevance by two authors using the pre-determined criteria. From this, 13 studies were deemed suitable. This review found that high-intensity interval training in children and adolescents is a time-effective method of improving cardiovascular disease biomarkers, but evidence regarding other health-related measures is more equivocal. Running-based sessions, at an intensity of >90% heart rate maximum/100-130% maximal aerobic velocity, two to three times a week and with a minimum intervention duration of 7 weeks, elicit the greatest improvements in participant health. While high-intensity interval training improves cardiovascular disease biomarkers, and the evidence supports the effectiveness of running-based sessions, as outlined above, further recommendations as to optimal exercise duration and rest intervals remain ambiguous owing to the paucity of literature and the methodological limitations of

  1. High-intensity exercise attenuates postprandial lipaemia and markers of oxidative stress.

    Science.gov (United States)

    Gabriel, Brendan; Ratkevicius, Aivaras; Gray, Patrick; Frenneaux, Michael P; Gray, Stuart R

    2012-09-01

    Regular exercise can reduce the risk of CVD (cardiovascular disease). Although moderate-intensity exercise can attenuate postprandial TAG (triacylglycerol), high-intensity intermittent exercise might be a more effective method to improve health. We compared the effects of high-intensity intermittent exercise and 30 min of brisk walking on postprandial TAG, soluble adhesion molecules and markers of oxidative stress. Nine men each completed three 2-day trials. On day 1, subjects rested (control), walked briskly for 30 min (walking) or performed 5×30 s maximal sprints (high-intensity). On day 2, subjects consumed a high-fat meal for breakfast and 3 h later for lunch. Blood samples were taken at various times and analysed for TAG, glucose, insulin, ICAM-1 (intracellular adhesion molecule-1), VCAM-1 (vascular adhesion molecule-1), TBARS (thiobarbituric acid- reactive substances), protein carbonyls and β-hydroxybutyrate. On day 2 of the high-intensity trial, there was a lower (Pwalking trial (8.98±2.84 mmol/l per 7 h). A trend (P=0.056) for a reduced total TAG AUC was also seen during the high-intensity trial (14.13±2.83 mmol/l per 7 h) compared with control (17.18±3.92 mmol/l per 7 h), walking showed no difference (16.33±3.51 mmol/l per 7 h). On day 2 of the high-intensity trial plasma TBARS and protein carbonyls were also reduced (Pwalking trials. In conclusion, high-intensity intermittent exercise attenuates postprandial TAG and markers of oxidative stress after the consumption of a high-fat meal.

  2. High-intensity interval training evokes larger serum BDNF levels compared with intense continuous exercise.

    Science.gov (United States)

    Saucedo Marquez, Cinthia Maria; Vanaudenaerde, Bart; Troosters, Thierry; Wenderoth, Nicole

    2015-12-15

    Exercise can have a positive effect on the brain by activating brain-derived neurotrophic factor (BDNF)-related processes. In healthy humans there appears to be a linear relationship between exercise intensity and the positive short-term effect of acute exercise on BDNF levels (i.e., the highest BDNF levels are reported after high-intensity exercise protocols). Here we performed two experiments to test the effectiveness of two high-intensity exercise protocols, both known to improve cardiovascular health, to determine whether they have a similar efficacy in affecting BDNF levels. Participants performed a continuous exercise (CON) protocol at 70% of maximal work rate and a high-intensity interval-training (HIT) protocol at 90% of maximal work rate for periods of 1 min alternating with 1 min of rest (both protocols lasted 20 min). We observed similar BDNF kinetics in both protocols, with maximal BDNF concentrations being reached toward the end of training (experiment 1). We then showed that both exercise protocols significantly increase BDNF levels compared with a rest condition (CON P = 0.04; HIT P high intensity exercise are slightly more effective than continuous high-intensity exercise for elevating serum BDNF. Additionally, 73% of the participants preferred the HIT protocol (P = 0.02). Therefore, we suggest that the HIT protocol might represent an effective and preferred intervention for elevating BDNF levels and potentially promoting brain health. Copyright © 2015 the American Physiological Society.

  3. High-intensity focused ultrasound ablation for treatment of hepatocellular carcinoma and hypersplenism: preliminary study.

    Science.gov (United States)

    Zhu, Jing; Zhu, Hui; Mei, Zhechuan; Jin, Chengbing; Ran, Lifeng; Zhou, Kun; Yang, Wei; Zhang, Lian; She, Chaokun

    2013-10-01

    The purpose of this work was to preliminarily investigate the efficacy and safety of high-intensity focused ultrasound treatment of hepatocellular carcinoma and hypersplenism. Nine patients with hepatocellular carcinoma complicated by hypersplenism (5 male and 4 female; median age, 56 years; range, 51-66 years) were treated with ultrasound-guided high-intensity focused ultrasound. Complications were recorded. Laboratory examination and magnetic resonance imaging were used to evaluate the efficacy. After high-intensity focused ultrasound treatment, mean spleen ablation ± SD of 28.76% ± 6.1% was discovered; meanwhile, the white blood cell count, platelet count, and liver function of the patients were substantially improved during the follow-up period. In addition, symptoms such as epistaxis and gingival bleeding were ameliorated or even eliminated, and the quality of life was improved. Follow-up imaging showed a nonperfused volume in the spleen and an absence of a tumor blood supply at the treated lesions in the liver. For the first time to our knowledge, high-intensity focused ultrasound ablation was used to treat hepatocellular carcinoma complicated by hypersplenism. High-intensity focused ultrasound may be an effective and safe alternative for treatment of hepatocellular carcinoma complicated by hypersplenism, but further studies are necessary to clarify the mechanisms.

  4. High-intensity x-ray holography: an approach to high-resolution snapshot imaging of biological specimens

    Energy Technology Data Exchange (ETDEWEB)

    Solem, J.C.

    1982-08-01

    The crucial physical and technological issues pertaining to the holographic imaging of biological structures with a short-pulse, high-intensity, high-quantum-energy laser were examined. The limitations of x-ray optics are discussed. Alternative holographic techniques were considered, and it was concluded that far-field Fresnel transform holography (Fraunhofer holography) using a photoresist recording surface is most tractable with near term technology. The hydrodynamic expansion of inhomogeneities within the specimen is discussed. It is shown that expansion is the major source of image blurring. Analytic expressions were derived for the explosion of protein concentrations in an x-ray transparent cytoplasm, compared with numerical calculations, and corrections derived to account for the competitive transport processes by which these inhomogeneities lose energy. It is concluded that for the near term Fresnel transform holography, particularly, far-field or Fraunhofer holography, is more practical than Fourier transform holography. Of the alternative fine grain recording media for use with Fresnel transform holography, a photo-resist is most attractive. For best resolution, exposure times must be limited to a few picoseconds, and this calls for investigation of mechanisms to shutter the laser or gate the recording surface. The best contrast ratio between the nitrogen-bearing polymers (protein and the nucleic acids) and water is between the K-edges of oxygen and nitrogen.

  5. Enhancement of High-Intensity Focused Ultrasound Heating by Short-Pulse Generated Cavitation

    Directory of Open Access Journals (Sweden)

    Shin Yoshizawa

    2017-03-01

    Full Text Available A target tissue can be thermally coagulated in high-intensity focused ultrasound (HIFU treatment noninvasively. HIFU thermal treatments have been clinically applied to various solid tumors. One of the problems in HIFU treatments is a long treatment time. Acoustically driven microbubbles can accelerate the ultrasonic heating, resulting in the significant reduction of the treatment time. In this paper, a method named “trigger HIFU exposure” which employs cavitation microbubbles is introduced and its results are reviewed. A trigger HIFU sequence consists of high-intensity short pulses followed by moderate-intensity long bursts. Cavitation bubbles induced in a multiple focal regions by rapidly scanning the focus of high-intensity pulses enhanced the temperature increase significantly and produced a large coagulation region with high efficiency.

  6. Physiological responses at the lactate-minimum-intensity with and without prior high-intensity exercise.

    Science.gov (United States)

    Zagatto, Alessandro Moura; Padulo, Johnny; Silva, Adelino Ramos Sanchez da; Müller, Paulo de Tarso Guerrero; Miyagi, Willian Eiji; Gobatto, Claudio Alexandre

    2016-11-01

    This study examined the physiological responses during exercise-to-exhaustion at the lactate-minimum-intensity with and without prior high-intensity exercise. Eleven recreationally trained males performed a graded exercise test, a lactate minimum test and two constant-load tests at lactate-minimum-intensity until exhaustion, which were applied with or without prior hyperlactatemia induction (i.e., 30-s Wingate test). The physiological responses were significantly different (P  0.05). In conclusion, the constant-load exercises performed at lactate-minimum-intensity with or without prior high-intensity exercise did not lead to the steady state of all analysed parameters; however, variables such as [La(-)], pH and [HCO3] - altered at the beginning of effort performed after high-intensity exercise - were reestablished after approximately 30 min of exercise.

  7. Effects of high-intensity physical training on muscle fiber characteristics in poststroke patients

    DEFF Research Database (Denmark)

    Andersen, Jesper Løvind; Jørgensen, Jørgen R.; Zeeman, Peter

    2017-01-01

    lower limbs had smaller muscle fiber size and lower type I and IIA and higher type IIX percentages than nonparetic lower limbs. Paretic lower limbs had increased type IIA fibers after training. At follow-up, no difference between the lower limbs remained. CONCLUSIONS: Although high-intensity training......INTRODUCTION: Stroke is a leading cause of disability worldwide. High-intensity physical training can improve muscle strength and gait speed, but adaptive mechanisms at the muscle cellular level are largely unknown. METHODS: Outpatients with poststroke hemiparesis participated in a 3-month...... rehabilitation program combining high-intensity strength and body-weight supported treadmill-training. Biopsies sampled bilaterally from vastus lateralis muscles, before, after, and at 1-year follow-up after intervention, were analyzed for fiber size, type, and capillarization. RESULTS: At baseline, paretic...

  8. [High intensity aerobic interval training improves peak oxygen consumption in patients with metabolic syndrome: CAT].

    Science.gov (United States)

    Espinoza Salinas, Alexis; Aguilera Eguía, Raúl; Cofre Bolados, Cristian; Zafra Santos, Edson; Pavéz Von Martens, Gustavo

    2014-06-06

    A number of cardiovascular risk factors characterizes the metabolic syndrome: insulin resistance (IR), low HDL cholesterol and high triglycerides. The aforementioned risk factors lead to elevated levels of abdominal adipose tissue, resulting in oxygen consumption deficiency. To verify the validity and applicability of using high intensity interval training (HIIT) in subjects with metabolic syndrome and to answer the following question: Can HIIT improve peak oxygen consumption? The systematic review "Effects of aerobic interval training on exercise capacity and metabolic risk factors in individuals with cardiometabolic disorders" was analyzed. Data suggests high intensity aerobic interval training increases peak oxygen consumption by a standardized mean difference of 3.60 mL/kg-1/min-1 (95% confidence interval, 0.28-4.91). In spite of the methodological shortcomings of the primary studies included in the systematic review, we reasonably conclude that implementation of high intensity aerobic interval training in subjects with metabolic syndrome, leads to increases in peak oxygen consumption.

  9. High-intensity discharge lamp and Duffing oscillator—Similarities and differences

    Science.gov (United States)

    Baumann, Bernd; Schwieger, Joerg; Stein, Ulrich; Hallerberg, Sarah; Wolff, Marcus

    2017-12-01

    The processes inside the arc tube of high-intensity discharge lamps are investigated using finite element simulations. The behavior of the gas mixture inside the arc tube is governed by differential equations describing mass, energy, and charge conservation, as well as the Helmholtz equation for the acoustic pressure and the Reynolds equations for the flow driven by buoyancy and Reynolds stresses. The model is highly nonlinear and requires a recursion procedure to account for the impact of acoustic streaming on the temperature and other fields. The investigations reveal the presence of a hysteresis and the corresponding jump phenomenon, quite similar to a Duffing oscillator. The similarities and, in particular, the differences of the nonlinear behavior of the high-intensity discharge lamp to that of a Duffing oscillator are discussed. For large amplitudes, the high-intensity discharge lamp exhibits a stiffening effect in contrast to the Duffing oscillator. It is speculated on how the stiffening might affect hysteresis suppression.

  10. High-intensity aerobic interval training in a patient with stable angina pectoris.

    Science.gov (United States)

    Meyer, Philippe; Guiraud, Thibaut; Gayda, Mathieu; Juneau, Martin; Bosquet, Laurent; Nigam, Anil

    2010-01-01

    Recently, high-intensity aerobic interval training was shown to be more effective than continuous moderate-intensity exercise for improving maximal aerobic capacity and endurance in patients with coronary heart disease. However, patients with exercise-induced ischemia were not included in those studies. We present the acute cardiopulmonary responses of a 67-yr-old man with stable angina pectoris during a 34-min session of high-intensity aerobic interval training. Exercise was well tolerated with neither significant arrhythmia nor elevation of cardiac troponin-T. We observed a complete disappearance of symptoms and signs of myocardial ischemia after 24 mins of exercise. This observation is similar to the warm-up angina phenomenon, an adaptation to myocardial ischemia that remains poorly understood. We conclude that high-intensity aerobic interval training is a promising mode of training for patients with stable coronary heart disease that should also be investigated further in patients with exercise-induced ischemia.

  11. Light field driven streak-camera for single-shot measurements of the temporal profile of XUV-pulses from a free-electron laser; Lichtfeld getriebene Streak-Kamera zur Einzelschuss Zeitstrukturmessung der XUV-Pulse eines Freie-Elektronen Lasers

    Energy Technology Data Exchange (ETDEWEB)

    Fruehling, Ulrike

    2009-10-15

    The Free Electron Laser in Hamburg (FLASH) is a source for highly intense ultra short extreme ultraviolet (XUV) light pulses with pulse durations of a few femtoseconds. Due to the stochastic nature of the light generation scheme based on self amplified spontaneous emission (SASE), the duration and temporal profile of the XUV pulses fluctuate from shot to shot. In this thesis, a THz-field driven streak-camera capable of single pulse measurements of the XUV pulse-profile has been realized. In a first XUV-THz pump-probe experiment at FLASH, the XUV-pulses are overlapped in a gas target with synchronized THz-pulses generated by a new THz-undulator. The electromagnetic field of the THz light accelerates photoelectrons produced by the XUV-pulses with the resulting change of the photoelectron momenta depending on the phase of the THz field at the time of ionisation. This technique is intensively used in attosecond metrology where near infrared streaking fields are employed for the temporal characterisation of attosecond XUV-Pulses. Here, it is adapted for the analysis of pulse durations in the few femtosecond range by choosing a hundred times longer far infrared streaking wavelengths. Thus, the gap between conventional streak cameras with typical resolutions of hundreds of femtoseconds and techniques with attosecond resolution is filled. Using the THz-streak camera, the time dependent electric field of the THz-pulses was sampled in great detail while on the other hand the duration and even details of the time structure of the XUV-pulses were characterized. (orig.)

  12. Study in Parkinson disease of exercise (SPARX): translating high-intensity exercise from animals to humans.

    Science.gov (United States)

    Moore, Charity G; Schenkman, Margaret; Kohrt, Wendy M; Delitto, Anthony; Hall, Deborah A; Corcos, Daniel

    2013-09-01

    A burgeoning literature suggests that exercise has a therapeutic benefit in persons with Parkinson disease (PD) and in animal models of PD, especially when animals exercise at high intensity. If exercise is to be prescribed as "first-line" or "add-on" therapy in patients with PD, we must demonstrate its efficacy and dose-response effects through testing phases similar to those used in the testing of pharmacologic agents. The SPARX Trial is a multicenter, randomized, controlled, single-blinded, Phase II study that we designed to test the feasibility of using high-intensity exercise to modify symptoms of PD and to simultaneously test the nonfutility of achieving a prespecified change in patients' motor scores on the Unified Parkinson Disease Rating Scale (UPDRS). The trial began in May 2102 and is in the process of screening, enrolling, and randomly assigning 126 patients with early-stage PD to 1 of 3 groups: usual care (wait-listed controls), moderate-intensity exercise (4 days/week at 60%-65% maximal heart rate [HRmax]), or high-intensity exercise (4 days/week at 80%-85% HRmax). At 6-month follow-up, the trial is randomly reassigning usual care participants to a moderate-intensity or high-intensity exercise group for the remaining 6 months. The goals of the Phase II trial are to determine if participants can exercise at moderate and high intensities; to determine if either exercise yields benefits consistent with meaningful clinical change (nonfutility); and to document safety and attrition. The advantage of using a non-futility approach allows us to efficiently determine if moderate- or high-intensity exercise warrants further large-scale investigation in PD. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Stretching Effects: High-intensity & Moderate-duration vs. Low-intensity & Long-duration.

    Science.gov (United States)

    Freitas, S R; Vaz, J R; Bruno, P M; Andrade, R; Mil-Homens, P

    2016-03-01

    This study examined whether a high-intensity, moderate-duration bout of stretching would produce the same acute effects as a low-intensity, long-duration bout of stretching. 17 volunteers performed 2 knee-flexor stretching protocols: a high-intensity stretch (i. e., 100% of maximum tolerable passive torque) with a moderate duration (243.5 ± 69.5-s); and a low-intensity stretch (50% of tolerable passive torque) with a long duration (900-s). Passive torque at a given sub-maximal angle, peak passive torque, maximal range of motion (ROM), and muscle activity were assessed before and after each stretching protocol (at intervals of 1, 30 and 60 min). The maximal ROM and tolerable passive torque increased for all time points following the high-intensity stretching (p0.05). 1 min post-stretching, the passive torque decreased in both protocols, but to a greater extent in the low-intensity protocol. 30 min post-test, torque returned to baseline for the low-intensity protocol and had increased above the baseline for the high-intensity stretches. The following can be concluded: 1) High-intensity stretching increases the maximal ROM and peak passive torque compared to low-intensity stretching; 2) low-intensity, long-duration stretching is the best way to acutely decrease passive torque; and 3) high-intensity, moderate-duration stretching increases passive torque above the baseline 30 min after stretching. © Georg Thieme Verlag KG Stuttgart · New York.

  14. High-intensity erotic visual stimuli de-activate the primary visual cortex in women.

    Science.gov (United States)

    Huynh, Hieu K; Beers, Caroline; Willemsen, Antoon; Lont, Erna; Laan, Ellen; Dierckx, Rudi; Jansen, Monique; Sand, Michael; Weijmar Schultz, Willibrord; Holstege, Gert

    2012-06-01

    The primary visual cortex, Brodmann's area (BA 17), plays a vital role in basic survival mechanisms in humans. In most neuro-imaging studies in which the volunteers have to watch pictures or movies, the primary visual cortex is similarly activated independent of the content of the pictures or movies. However, in case the volunteers perform demanding non-visual tasks, the primary visual cortex becomes de-activated, although the amount of incoming visual sensory information is the same. Do low- and high-intensity erotic movies, compared to neutral movies, produce similar de-activation of the primary visual cortex? Brain activation/de-activation was studied by Positron Emission Tomography scanning of the brains of 12 healthy heterosexual premenopausal women, aged 18-47, who watched neutral, low- and high-intensity erotic film segments. We measured differences in regional cerebral blood flow (rCBF) in the primary visual cortex during watching neutral, low-intensity erotic, and high-intensity erotic film segments. Watching high-intensity erotic, but not low-intensity erotic movies, compared to neutral movies resulted in strong de-activation of the primary (BA 17) and adjoining parts of the secondary visual cortex. The strong de-activation during watching high-intensity erotic film might represent compensation for the increased blood supply in the brain regions involved in sexual arousal, also because high-intensity erotic movies do not require precise scanning of the visual field, because the impact is clear to the observer. © 2012 International Society for Sexual Medicine.

  15. Influence of mature men way of life on highly intensive physical activity

    Directory of Open Access Journals (Sweden)

    O.B. Pryshva

    2017-04-01

    Full Text Available Highly intensive physical activity is the most effective for men’s health protection. In modern life conditions its level is insufficient. It requires organism’s appropriate physical activity, which is determined by way of life. Especially important it is before trainings. Purpose: to study special aspects of different intensity’s physical activity; of eating special food and sleeping regime of mature men before their highly intensive physical trainings. Material: in experiment men (n=26, age - 35-53years, who practice healthy life style and independent physical activity of high intensity, participated. We used bio-register Basis B1. Every day we registered: Peak - physical activity of different intensity; duration and quality of sleep; relative weight of consumed food. Besides, we calculated body mass index and physical condition. The study was conducted during 30 days in winter period. The following results were compared: indicators before not planned physical activity and average-monthly indicators. Results: Before arbitrary physical functioning we found in men: confident weakening of average intensity (by 9-11% and low intensity (by 10% physical activity; confident increase of consumed food’s relative weight (by 6.82%, vegetarian food (by 10.64% and raw food (by 7.61%; confident reduction of animal origin food (by 8.7%. No changes were found in duration and quality of sleep before highly intensive physical functioning. Conclusions: specific features of mature men’s way of life before their not planned highly intensive physical functioning are as follows: reduction of general physical activity; increase of consumed food. These factors facilitate energy accumulation in organism for its realization in highly intensive physical functioning the next day.

  16. Electron localization in fragmentation of H2 with CEP stabilized laser pulses

    Science.gov (United States)

    Kremer, Manuel; Fischer, Bettina; Rudenko, Artem; de Jesus, Vitor L. B.; Schröter, Claus Dieter; Feuerstein, Bernold; Moshammer, Robert; Ullrich, Joachim

    2009-11-01

    Fully differential data on ionization and dissociation of H2 in ultra-short (~ 6 fs), linearly polarized, intense (~ 4.1014W/cm2) laser pulses with stabilized carrier-envelope-phase (CEP) have been measured using a reaction microscope. Depending on the CEP of the laser pulses we see a clear asymmetry in the emission direction of the created protons. Contrary to earlier measurements by Kling et al. [1] we observe the highest asymmetry for kinetic energy releases (proton energy) between 0-2 eV. This excludes the electron re-collision mechanism suggested in [1] as dominant excitation channel and requires another explanation.

  17. A “slingshot” laser-driven acceleration mechanism of plasma electrons

    Energy Technology Data Exchange (ETDEWEB)

    Fiore, Gaetano, E-mail: gaetano.fiore@na.infn.it [Dip. di Matematica e Applicazioni, Università “Federico II”, Complesso Universitario M. S. Angelo, Via Cintia, 80126 Napoli (Italy); INFN, Sezione di Napoli, Complesso Universitario M. S. Angelo, Via Cintia, 80126 Napoli (Italy); De Nicola, Sergio [SPIN-CNR, Complesso Universitario M. S. Angelo, Via Cintia, 80126 Napoli (Italy); INFN, Sezione di Napoli, Complesso Universitario M. S. Angelo, Via Cintia, 80126 Napoli (Italy)

    2016-09-01

    We briefly report on the recently proposed Fiore et al. [1] and Fiore and De Nicola [2] electron acceleration mechanism named “slingshot effect”: under suitable conditions the impact of an ultra-short and ultra-intense laser pulse against the surface of a low-density plasma is expected to cause the expulsion of a bunch of superficial electrons with high energy in the direction opposite to that of the pulse propagation; this is due to the interplay of the huge ponderomotive force, huge longitudinal field arising from charge separation, and the finite size of the laser spot.

  18. Ultrasound-guided high-intensity focused ultrasound ablation for treating uterine arteriovenous malformation.

    Science.gov (United States)

    Yan, X; Zhao, C; Tian, C; Wen, S; He, X; Zhou, Y

    2017-08-01

    To explore HIFU treatment for uterine arteriovenous malformation. A case report. Gynaecological department in a university teaching hospital of China. A patient with uterine arteriovenous malformation. The diagnosis of uterine arteriovenous malformation was made through MRI. Ultrasound-guided high-intensity focused ultrasound (USgHIFU) ablation was performed. HIFU is effective in treating uterine arteriovenous malformation. The patient had reduction of the lesion volume and obvious symptom relief, without significant adverse effects. HIFU can be used as a new treatment option for uterine arteriovenous malformation. Ultrasound-guided high-intensity focused ultrasound ablation is effective in treating uterine arteriovenous malformation. © 2017 Royal College of Obstetricians and Gynaecologists.

  19. The Benefits of High Intensity Functional Training (HIFT) Fitness Programs for Military Personnel

    Science.gov (United States)

    Haddock, Christopher K.; Poston, Walker S.C.; Heinrich, Katie M.; Jahnke, Sara A.; Jitnarin, Nattinee

    2016-01-01

    High intensity functional training (HIFT) programs are designed to address multiple fitness domains, potentially providing improved physical and mental readiness in a changing operational environment. Programs consistent with HIFT principals such as CrossFit, SEALFIT and the US Marine Corps’ High Intensity Tactical Training (HITT) program are increasingly popular among military personnel. This article reviews the practical, health, body composition, and military fitness implications of HIFT exercise programs. We conclude that, given the unique benefits of HIFT, the military should consider evaluating whether these programs should be the standard for military fitness training. PMID:27849484

  20. Fluorescent and high intensity discharge lamp use in chambers and greenhouses

    Science.gov (United States)

    Langhans, Robert W.

    1994-01-01

    Fluorescent and High Intensity Discharge lamps have opened up great opportunities for researchers to study plant growth under controlled environment conditions and for commercial growers to increase plant production during low/light periods. Specific technical qualities of fluorescent and HID lamps have been critically reviewed. I will direct my remarks to fluorescent and high intensity discharge (HID) lamps in growth chambers, growth rooms, and greenhouses. I will discuss the advantages and disadvantages of using each lamp in growth chambers, growth rooms and greenhouses.

  1. Changes in satellite cells in human skeletal muscle after a single bout of high intensity exercise

    DEFF Research Database (Denmark)

    Crameri, Regina M; Langberg, Henning; Magnusson, Peter

    2004-01-01

    No studies to date have reported activation of satellite cells in vivo in human muscle after a single bout of high intensity exercise. In this investigation, eight individuals performed a single bout of high intensity exercise with one leg, the contralateral leg being the control. A significant...... increase in mononuclear cells staining for the neural cell adhesion molecule (N-CAM) and fetal antigen 1 (FA1) were observed within the exercised human vastus lateralis muscle on days 4 and 8 post exercise. In addition, a significant increase in the concentration of the FA1 protein was determined...

  2. Effects of high-intensity resistance training on bone mineral density in young male powerlifters.

    Science.gov (United States)

    Tsuzuku, S; Ikegami, Y; Yabe, K

    1998-10-01

    The effects of high-intensity resistance training on bone mineral density (BMD) and its relationship to strength were investigated. Lumbar spine (L2-L4), proximal femur, and whole body BMD were measured in 10 male powerlifters and 11 controls using dual-energy X-ray absorptiometry (DXA). There were significant differences in lumbar spine and whole body BMD between powerlifters and controls, but not in proximal femur BMD. A significant correlation was found between lumbar spine BMD and powerlifting performance. These results suggest that high-intensity resistance training is effective in increasing the lumbar spine and whole body BMD.

  3. Fluorescent and high intensity discharge lamp use in chambers and greenhouses

    Science.gov (United States)

    Langhans, Robert W.

    1994-03-01

    Fluorescent and High Intensity Discharge lamps have opened up great opportunities for researchers to study plant growth under controlled environment conditions and for commercial growers to increase plant production during low/light periods. Specific technical qualities of fluorescent and HID lamps have been critically reviewed. I will direct my remarks to fluorescent and high intensity discharge (HID) lamps in growth chambers, growth rooms, and greenhouses. I will discuss the advantages and disadvantages of using each lamp in growth chambers, growth rooms and greenhouses.

  4. Advanced concepts for high-power, short-pulse CO2 laser development

    Science.gov (United States)

    Gordon, Daniel F.; Hasson, Victor; von Bergmann, Hubertus; Chen, Yu-hsin; Schmitt-Sody, A.; Penano, Joseph R.

    2016-06-01

    Ultra-short pulse lasers are dominated by solid-state technology, which typically operates in the near-infrared. Efforts to extend this technology to longer wavelengths are meeting with some success, but the trend remains that longer wavelengths correlate with greatly reduced power. The carbon dioxide (CO2) laser is capable of delivering high energy, 10 micron wavelength pulses, but the gain structure makes operating in the ultra-short pulse regime difficult. The Naval Research Laboratory and Air Force Research Laboratory are developing a novel CO2 laser designed to deliver ~1 Joule, ~1 picosecond pulses, from a compact gain volume (~2x2x80 cm). The design is based on injection seeding an unstable resonator, in order to achieve high energy extraction efficiency, and to take advantage of power broadening. The unstable resonator is seeded by a solid state front end, pumped by a custom built titanium sapphire laser matched to the CO2 laser bandwidth. In order to access a broader range of mid infrared wavelengths using CO2 lasers, one must consider nonlinear frequency multiplication, which is non-trivial due to the bandwidth of the 10 micron radiation.

  5. Advanced metaheuristic algorithms for laser optimization in optical accelerator technologies

    Energy Technology Data Exchange (ETDEWEB)

    Tomizawa, Hiromitsu, E-mail: hiro@spring8.or.jp [Japan Synchrotron Radiation Research Institute (JASRI), XFEL Joint Project/SPring-8, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo (Japan)

    2011-10-15

    Lasers are among the most important experimental tools for user facilities, including synchrotron radiation and free electron lasers (FEL). In the synchrotron radiation field, lasers are widely used for experiments with Pump-Probe techniques. Especially for X-ray-FELs, lasers play important roles as seed light sources or photocathode-illuminating light sources to generate a high-brightness electron bunch. For future accelerators, laser-based techonologies such as electro-optic (EO) sampling to measure ultra-short electron bunches and optical-fiber-based femtosecond timing systems have been intensively developed in the last decade. Therefore, controls and optimizations of laser pulse characteristics are strongly required for many kinds of experiments and improvement of accelerator systems. However, people believe that lasers should be tuned and customized for each requirement manually by experts. This makes it difficult for laser systems to be part of the common accelerator infrastructure. Automatic laser tuning requires sophisticated algorithms, and the metaheuristic algorithm is one of the best solutions. The metaheuristic laser tuning system is expected to reduce the human effort and time required for laser preparations. I have shown some successful results on a metaheuristic algorithm based on a genetic algorithm to optimize spatial (transverse) laser profiles, and a hill-climbing method extended with a fuzzy set theory to choose one of the best laser alignments automatically for each machine requirement.

  6. Effect of a High-intensity Interval Training method on maximum oxygen consumption in Chilean schoolchildren

    Directory of Open Access Journals (Sweden)

    Sergio Galdames-Maliqueo

    2017-12-01

    Full Text Available Introduction: The low levels of maximum oxygen consumption (VO2max evaluated in Chilean schoolchildren suggest the startup of trainings that improve the aerobic capacity. Objective: To analyze the effect of a High-intensity Interval Training method on maximum oxygen consumption in Chilean schoolchildren. Materials and methods: Thirty-two high school students from the eighth grade, who were divided into two groups, were part of the study (experimental group = 16 students and control group = 16 students. The main analyzed variable was the maximum oxygen consumption through the Course Navette Test. A High-intensity Interval training method was applied based on the maximum aerobic speed obtained through the Test. A mixed ANOVA was used for statistical analysis. Results: The experimental group showed a significant increase in the Maximum Oxygen Consumption between the pretest and posttest when compared with the control group (p < 0.0001. Conclusion: The results of the study showed a positive effect of the High-intensity Interval Training on the maximum consumption of oxygen. At the end of the study, it is concluded that High-intensity Interval Training is a good stimulation methodology for Chilean schoolchildren.

  7. In vivo photoacoustics and high frequency ultrasound imaging of mechanical high intensity focused ultrasound (HIFU) ablation

    NARCIS (Netherlands)

    Daoudi, K.; Hoogenboom, M.; Brok, M.H. den; Eikelenboom, D.C.; Adema, G.J.; Futterer, J.J.; Korte, C.L. de

    2017-01-01

    The thermal effect of high intensity focused ultrasound (HIFU) has been clinically exploited over a decade, while the mechanical HIFU is still largely confined to laboratory investigations. This is in part due to the lack of adequate imaging techniques to better understand the in-vivo pathological

  8. Towards MR-guided high intensity focused ultrasound ablation of liver tumors

    NARCIS (Netherlands)

    Wijlemans, J.W.

    2015-01-01

    Magnetic Resonance-guided High Intensity Focused Ultrasound (MR-HIFU) is a promising technique which can be used for completely non-invasive tissue ablation. The converging ultrasound beam penetrates the skin and subcutaneous tissues with damage, while heating the tissue only in the focal point. The

  9. MRI-guided High-Intensity Focused Ultrasound of Breast Cancer

    NARCIS (Netherlands)

    Merckel, L.G.

    2014-01-01

    Magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) is a promising technique for completely noninvasive tumor ablation. This thesis focuses on its application for the treatment of patients with breast cancer. The first part of the thesis describes the role of breast MRI for

  10. Magnetic Resonance-guided high intensity focused ultrasound in the presence of biopsy markers

    NARCIS (Netherlands)

    Mougenot, C; Moonen, Chrit

    2017-01-01

    Background: Magnetic Resonance guided High Intensity Focused ultrasound (MR-HIFU) offers precise non-invasive thermotherapy for clinical applications such as the treatment of breast lesions. However, patients with a biopsy marker are usually not eligible for MR-HIFU treatment. This study

  11. Long term high intensity exercise and damage of small joints in rheumatoid arthritis.

    NARCIS (Netherlands)

    Jong, Z. de; Munneke, M.; Zwinderman, A.H.; Kroon, H.M.; Ronday, K.H.; Lems, W.F.; Dijkmans, B.A.C.; Breedveld, F.C.; Vliet Vlieland, T.P.M.; Hazes, J.M.W.; Huizinga, T.W.J.

    2004-01-01

    OBJECTIVE: To investigate the effect of long term high intensity weightbearing exercises on radiological damage of the joints of the hands and feet in patients with rheumatoid arthritis (RA). METHODS: Data of the 281 completers of a 2 year randomised controlled trial comparing the effects of usual

  12. Mechanical high-intensity focused ultrasound destruction of soft tissue: working mechanisms and physiologic effects

    NARCIS (Netherlands)

    Hoogenboom, M.; Eikelenboom, D.C.; Brok, M.H.M.G.M. den; Heerschap, A.; Futterer, J.J.; Adema, G.J.

    2015-01-01

    The best known method of high-intensity focused ultrasound is thermal ablation, but interest in non-thermal, mechanical destruction is increasing. The advantages of mechanical ablation are that thermal protein denaturation remains limited and less damage is created to the surrounding tissue by

  13. Effects of high-intensity interval cycling performed after resistance training on muscle strength and hypertrophy.

    Science.gov (United States)

    Tsitkanou, S; Spengos, K; Stasinaki, A-N; Zaras, N; Bogdanis, G; Papadimas, G; Terzis, G

    2017-11-01

    Aim of the study was to investigate whether high-intensity interval cycling performed immediately after resistance training would inhibit muscle strength increase and hypertrophy expected from resistance training per se. Twenty-two young men were assigned into either resistance training (RE; N = 11) or resistance training plus high-intensity interval cycling (REC; N = 11). Lower body muscle strength and rate of force development (RFD), quadriceps cross-sectional area (CSA) and vastus lateralis muscle architecture, muscle fiber type composition and capillarization, and estimated aerobic capacity were evaluated before and after 8 weeks of training (2 times per week). Muscle strength and quadriceps CSA were significantly and similarly increased after both interventions. Fiber CSA increased significantly and similarly after both RE (type I: 13.6 ± 3.7%, type IIA: 17.6 ± 4.4%, type IIX: 23.2 ± 5.7%, P high-intensity interval cycling performed after heavy-resistance exercise may not inhibit resistance exercise-induced muscle strength/hypertrophy after 2 months of training, while it prompts aerobic capacity and muscle capillarization. The addition of high-intensity cycling after heavy-resistance exercise may decrease RFD partly due to muscle architectural changes. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Bone metastasis treatment using magnetic resonance-guided high intensity focused ultrasound

    NARCIS (Netherlands)

    Yeo, Sin Yuin; Elevelt, Aaldert; Donato, Katia; van Rietbergen, Bert; ter Hoeve, Natalie D.; van Diest, Paul J.|info:eu-repo/dai/nl/075281775; Grüll, Holger

    2015-01-01

    Objectives: Bone pain resulting from cancer metastases reduces a patient's quality of life. Magnetic Resonance-guided High Intensity Focused Ultrasound (MR-HIFU) is a promising alternative palliative thermal treatment technique for bone metastases that has been tested in a few clinical studies.

  15. A High Intensity Multi-Purpose D-D Neutron Generator for Nuclear Engineering Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Ka-Ngo Leung; Jasmina L. Vujic; Edward C. Morse; Per F. Peterson

    2005-11-29

    This NEER project involves the design, construction and testing of a low-cost high intensity D-D neutron generator for teaching nuclear engineering students in a laboratory environment without radioisotopes or a nuclear reactor. The neutron generator was designed, fabricated and tested at Lawrence Berkeley National Laboratory (LBNL).

  16. Effectiveness and Safety of High-Intensity Interval Training in Patients With Type 2 Diabetes

    Science.gov (United States)

    Francois, Monique E.

    2015-01-01

    IN BRIEF Recent research has shown that high-intensity interval training (HIIT) can promote improvements in glucose control and cardiovascular health in individuals with type 2 diabetes. This article summarizes the evidence and highlights the ways in which HIIT might be safely implemented as an adjunct to more traditional exercise approaches. PMID:25717277

  17. Effects of High Intensity Interval Training on Increasing Explosive Power, Speed, and Agility

    Science.gov (United States)

    Fajrin, F.; Kusnanik, N. W.; Wijono

    2018-01-01

    High Intensity Interval Training (HIIT) is a type of exercise that combines high-intensity exercise and low intensity exercise in a certain time interval. This type of training is very effective and efficient to improve the physical components. The process of improving athletes achievement related to how the process of improving the physical components, so the selection of a good practice method will be very helpful. This study aims to analyze how is the effects of HIIT on increasing explosive power, speed, and agility. This type of research is quantitative with quasi-experimental methods. The design of this study used the Matching-Only Design, with data analysis using the t-test (paired sample t-test). After being given the treatment for six weeks, the results showed there are significant increasing in explosive power, speed, and agility. HIIT in this study used a form of exercise plyometric as high-intensity exercise and jogging as mild or moderate intensity exercise. Increase was due to the improvement of neuromuscular characteristics that affect the increase in muscle strength and performance. From the data analysis, researchers concluded that, Exercises of High Intensity Interval Training significantly effect on the increase in Power Limbs, speed, and agility.

  18. Work in progress at the North Area High Intensity Facility (NAHIF)

    CERN Multimedia

    CERN PhotoLab

    1979-01-01

    The photo shows the exit of the two MBN-type magnets in tunnel TDC85 (upstream of TCC8), used to 'switch' the primary proton beam either towards target T8 (to the left) or onto target T10 (straight) to produce the H10 or the F12 (high-intensity electron/gamma) beam, respectively.

  19. Effects of music and video on perceived exertion during high-intensity exercise

    Directory of Open Access Journals (Sweden)

    Enoch C. Chow

    2017-03-01

    Conclusion: Music and video in combination may result in lower perceived exertion during high-intensity exercise when compared to music or video in isolation. Future research will be necessary to test if reductions in perceived exertion in response to dissociative attentional stimuli have implications for exercise adherence.

  20. Dynamics of cavitation clouds within a high-intensity focused ultrasonic beam

    NARCIS (Netherlands)

    Lu, Yuan; Katz, Joseph; Prosperetti, Andrea

    2013-01-01

    In this experimental study, we generate a 500 kHz high-intensity focused ultrasonic beam, with pressure amplitude in the focal zone of up to 1.9 MPa, in initially quiescent water. The resulting pressure field and behavior of the cavitation bubbles are measured using high-speed digital in-line

  1. Role transition from mental health nurse to IAPT high intensity psychological therapist.

    Science.gov (United States)

    Robinson, Simon; Kellett, Stephen; King, Ingrid; Keating, Val

    2012-05-01

    The Improving Access to Psychological Therapies (IAPT) initiative has depended on the training of a new NHS mental health workforce. At step 3 of the stepped care model, capacity building has required the recruitment of a wide range of mental health professionals into high intensity therapists training posts. This shift naturally entails role transition on the part of trainees into delivering cognitive behavioural psychotherapy (CBP), but no previous research has examined the experience of such transitions. To describe the lived experience of transition from mental health nurse to IAPT high intensity therapist and to identify possible factors which moderate effective role conversions. Six qualified high intensity therapists were interviewed using a semi-structured interview and the subsequent interviews transcribed. Thematic content analysis (TCA) was used to analyze personal accounts of role transition. All participants had previously been mental health nurses and attended the same IAPT high intensity therapist (HIT) training programme. Six key themes were apparent from the TCA. Three interconnected themes concerning supervision (style, impact of approach and historical context) and three additional themes of the challenge of learning a new clinical approach, high need for support, and forming a new psychotherapist identity. Findings suggest supervision is the most important factor in supporting complex psychotherapy role transitions. Clinical supervisors may need to incorporate dedicated time on role and identity shift during CBP training to ensure effective assimilation and transition. Methodological short-comings are identified and discussed.

  2. Effects of 12 weeks high-intensity & reduced-volume training in elite athletes

    DEFF Research Database (Denmark)

    Kilen, Anders; Larsson, Tanja Hultengren; Jørgensen, Majke

    2014-01-01

    It was investigated if high-intensity interval training (HIT) at the expense of total training volume improves performance, maximal oxygen uptake and swimming economy. 41 elite swimmers were randomly allocated to a control (CON) or HIT group. For 12 weeks both groups trained ∼12 h per week. HIT...

  3. Expectancy of ergogenicity from sodium bicarbonate ingestion increases high-intensity cycling capacity

    National Research Council Canada - National Science Library

    Higgins, Matthew F; Shabir, Akbar

    2016-01-01

    ... ) influenced subsequent high-intensity cycling capacity. Eight recreationally active males (age, 21 ± 1 years; body mass, 75 ± 8 kg; height, 178 ± 4 cm; W PEAK = 205 ± 22 W) performed a graded incremental test to assess peak power output...

  4. High Intensity Pressure Noise Transmission in Human Ear: A Three Dimensional Simulation Study

    Science.gov (United States)

    Hawa, Takumi; Gan, Rong; Leckness, Kegan

    2015-03-01

    High intensity pressure noise generated by explosions and jet engines causes auditory damage and hearing loss of the military service personals, which are the most common disabilities in the veterans. Authors have investigated the high intensity pressure noise transmission from the ear canal to middle ear cavity. A fluid-structure interaction with a viscoelastic model for the tympanic membrane (TM) as well as the ossicular chain has been considered in the study. For the high intensity pressure simulation the geometry of the ear was based on a 3D finite element (FE) model of the human ear reported by Gan et al. (Ann Biomed Eng 2004). The model consists of the ear canal, TM, ossicular chain, and the middle ear cavity. The numerical approach includes two steps: 1) FE based finite-volume method simulation to compute pressure distributions in the ear canal and the middle ear cavity using CFX; and 2) FE modeling of TM and middle ear ossicles in response to high intensity sound using multi-physics analysis in ANSYS. The simulations provide the displacement of the TM/ossicular chain and the pressure fields in the ear canal and the middle ear cavity. These results are compared with human temporal bone experimental data obtained in our group. This work was supported by DOD W81XWH-14-1-0228.

  5. Systematic review of high-intensity focused ultrasound ablation in the treatment of breast cancer

    NARCIS (Netherlands)

    Peek, M.C.L.; Ahmed, M.; Napoli, A.; ten Haken, Bernard; McWilliams, S.; Usiskin, S.I.; Pinder, S.E.; Van Hemelrijck, M.; Douek, M.

    2015-01-01

    Background: A systematic review was undertaken to assess the clinical efficacy of non-invasive high-intensity focused ultrasound (HIFU) ablation in the treatment of breast cancer. Methods: MEDLINE/PubMed library databases were used to identify all studies published up to December 2013 that evaluated

  6. Moderate-to-High Intensity Physical Exercise in Patients with Alzheimer's Disease

    DEFF Research Database (Denmark)

    Hoffmann, Kristine; Sobol, Nanna A; Frederiksen, Kristian S

    2015-01-01

    BACKGROUND: Studies of physical exercise in patients with Alzheimer's disease (AD) are few and results have been inconsistent. OBJECTIVE: To assess the effects of a moderate-to-high intensity aerobic exercise program in patients with mild AD. METHODS: In a randomized controlled trial, we recruited...

  7. Selected List of Low Energy Beam Transport Facilities for Light-Ion, High-Intensity Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Prost, L. R. [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)

    2016-02-17

    This paper presents a list of Low Energy Beam Transport (LEBT) facilities for light-ion, high-intensity accelerators. It was put together to facilitate comparisons with the PXIE LEBT design choices. A short discussion regarding the importance of the beam perveance in the choice of the transport scheme follows.

  8. Psychophysiological effects of music on acute recovery from high-intensity interval training.

    Science.gov (United States)

    Jones, Leighton; Tiller, Nicholas B; Karageorghis, Costas I

    2017-03-01

    Numerous studies have examined the multifarious effects of music applied during exercise but few have assessed the efficacy of music as an aid to recovery. Music might facilitate physiological recovery via the entrainment of respiratory rhythms with music tempo. High-intensity exercise training is not typically associated with positive affective responses, and thus ways of assuaging negative affect warrant further exploration. This study assessed the psychophysiological effects of music on acute recovery and prevalence of entrainment in between bouts of high-intensity exercise. Thirteen male runners (M age =20.2±1.9years; BMI=21.7±1.7; V̇O 2 max=61.6±6.1mL·kg·min -1 ) completed three exercise sessions comprising 5×5-min bouts of high-intensity intervals interspersed with 3-min periods of passive recovery. During recovery, participants were administered positively-valenced music of a slow-tempo (55-65bpm), fast-tempo (125-135bpm), or a no-music control. A range of measures including affective responses, RPE, cardiorespiratory indices (gas exchange and pulmonary ventilation), and music tempo-respiratory entrainment were recorded during exercise and recovery. Fast-tempo, positively-valenced music resulted in higher Feeling Scale scores throughout recovery periods (pmusic-moderated differences in cardiorespiratory responses. In conclusion, fast-tempo, positively-valenced music applied during recovery periods engenders a more pleasant experience. However, there is limited evidence that music expedites cardiorespiratory recovery in between bouts of high-intensity exercise. These findings have implications for athletic training strategies and individuals seeking to make high-intensity exercise sessions more pleasant. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Effects of leg massage on recovery from high intensity cycling exercise

    Science.gov (United States)

    Robertson, A; Watt, J; Galloway, S

    2004-01-01

    Background: The effect of massage on recovery from high intensity exercise is debatable. Many studies on massage suffer from methodological flaws such as poor standardisation of previous exercise, lack of dietary control, and inappropriate massage duration. Objective: To examine the effects of leg massage compared with passive recovery on lactate clearance, muscular power output, and fatigue characteristics after repeated high intensity cycling exercise, with the conditions before the intervention controlled and standardised. Methods: Nine male games players participated. They attended the laboratory on two occasions one week apart and at the same time of day. Dietary intake and activity were replicated for the two preceding days on each occasion. After baseline measurement of heart rate and blood lactate concentration, subjects performed a standardised warm up on the cycle ergometer. This was followed by six standardised 30 second high intensity exercise bouts, interspersed with 30 seconds of active recovery. After five minutes of active recovery and either 20 minutes of leg massage or supine passive rest, subjects performed a second standardised warm up and a 30 second Wingate test. Capillary blood samples were drawn at intervals, and heart rate, peak power, mean power, and fatigue index were recorded. Results: There were no significant differences in mean power during the initial high intensity exercise bouts (p = 0.92). No main effect of massage was observed on blood lactate concentration between trials (p = 0.82) or heart rate (p = 0.81). There was no difference in the maximum power (p = 0.75) or mean power (p = 0.66) in the subsequent Wingate test, but a significantly lower fatigue index was observed in the massage trial (p = 0.04; mean (SD) fatigue index 30.2 (4.1)% v 34.2 (3.3)%). Conclusions: No measurable physiological effects of leg massage compared with passive recovery were observed on recovery from high intensity exercise, but the subsequent effect on

  10. Reliability of a Novel High Intensity One Leg Dynamic Exercise Protocol to Measure Muscle Endurance.

    Directory of Open Access Journals (Sweden)

    Benjamin Pageaux

    Full Text Available We recently developed a high intensity one leg dynamic exercise (OLDE protocol to measure muscle endurance and investigate the central and peripheral mechanisms of muscle fatigue. The aims of the present study were to establish the reliability of this novel protocol and describe the isokinetic muscle fatigue induced by high intensity OLDE and its recovery. Eight subjects performed the OLDE protocol (time to exhaustion test of the right leg at 85% of peak power output three times over a week period. Isokinetic maximal voluntary contraction torque at 60 (MVC60, 100 (MVC100 and 140 (MVC140 deg/s was measured pre-exercise, shortly after exhaustion (13 ± 4 s, 20 s (P20 and 40 s (P40 post-exercise. Electromyographic (EMG signal was analyzed via the root mean square (RMS for all three superficial knee extensors. Mean time to exhaustion was 5.96 ± 1.40 min, coefficient of variation was 8.42 ± 6.24%, typical error of measurement was 0.30 min and intraclass correlation was 0.795. MVC torque decreased shortly after exhaustion for all angular velocities (all P < 0.001. MVC60 and MVC100 recovered between P20 (P < 0.05 and exhaustion and then plateaued. MVC140 recovered only at P40 (P < 0.05. High intensity OLDE did not alter maximal EMG RMS of the three superficial knee extensors during MVC. The results of this study demonstrate that this novel high intensity OLDE protocol could be reliably used to measure muscle endurance, and that muscle fatigue induced by high intensity OLDE should be examined within ~ 30 s following exhaustion.

  11. Development of Laser Plasma X-ray Microbeam Irradiation System and Radiation Biological Application

    Science.gov (United States)

    Sato, Katsutoshi; Nishikino, Masaharu; Numasaki, Hodaka; Kawachi, Tetsuya; Teshima, Teruki; Nishimura, Hiroaki

    Laser plasma x-ray source has the features such as ultra short pulse, high brilliance, monochromaticity, and focusing ability. These features are excellent compared with conventional x-ray source. In order to apply the laser plasma x-ray source to the biomedical study and to more closely research the radiobilogical responce of the cancer cell such as radiation induced bystander effect, we have developed x-ray microbeam system using laser plasma x-ray source. The absorbed dose of laser plasma x-ray was estimated with Gafchromic EBT film and DNA double strand breaks on the cells were detected by immunofluorescence staining. When the cells were irradiated with laser plasma x-ray, the circular regions existing γ-H2AX positive cells were clearly identified. The usefulness of the laser plasma x-ray on the radiobiological study was proved in this research.

  12. High intensity focused ultrasound (HIFU as the alternative method of treatment of oncourological diseases

    Directory of Open Access Journals (Sweden)

    Blyumberg B.I.

    2012-12-01

    Full Text Available Increasing interest devoted to technology of high intensity focused ultrasound (high-intensity focused ultrasound, HIFU, basically, is explained by a wide spectrum of potential fields of application at minimum invasiveness of the given method. In oncourology HIFU is applied in prostate and kidney cancer. In case of tumors of renal parenchyma the given technique is being clinically tested, while HIFU is currently used in the practice of European oncourologists in treatment of prostate cancer. The majority of the references describing the results of HIFU application in prostate cancer is based on data of a number of clinical observations. It has been proved that HIFU is a possible method of treatment of highly — and moderate-differentiated tumors, and local relapses after remote radial therapy.

  13. Transverse Beam Halo Measurements at High Intensity Neutrino Source (HINS) using Vibrating Wire Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, M.; Hanna, B.; Scarpine, V.; Shiltsev, V.; Steimel, J.; Artinian, S.; Arutunian, S.

    2015-02-26

    The measurement and control of beam halos will be critical for the applications of future high-intensity hadron linacs. In particular, beam profile monitors require a very high dynamic range when used for the transverse beam halo measurements. In this study, the Vibrating Wire Monitor (VWM) with aperture 60 mm was installed at the High Intensity Neutrino Source (HINS) front-end to measure the transverse beam halo. A vibrating wire is excited at its resonance frequency with the help of a magnetic feedback loop, and the vibrating and sensitive wires are connected through a balanced arm. The sensitive wire is moved into the beam halo region by a stepper motor controlled translational stage. We study the feasibility of the vibrating wire for the transverse beam halo measurements in the low-energy front-end of the proton linac.

  14. Effects of High-Intensity Blood Flow Restriction Exercise on Muscle Fatigue

    Directory of Open Access Journals (Sweden)

    Neto Gabriel R.

    2014-07-01

    Full Text Available Strength training combined with blood flow restriction (BFR have been used to improve the levels of muscle adaptation. The aim of this paper was to investigate the acute effect of high intensity squats with and without blood flow restriction on muscular fatigue levels. Twelve athletes (aged 25.95 ± 0.84 years were randomized into two groups: without Blood Flow Restriction (NFR, n = 6 and With Blood Flow Restriction (WFR, n = 6 that performed a series of free weight squats with 80% 1-RM until concentric failure. The strength of the quadriceps extensors was assessed in a maximum voluntary isometric contraction integrated to signals from the surface electromyogram. The average frequency showed significant reductions in the WFR group for the vastus lateralis and vastus medialis muscles, and intergroup only for the vastus medialis. In conclusion, a set of squats at high intensity with BFR could compromise muscle strength immediately after exercise, however, differences were not significant between groups.

  15. Beam Dynamics Studies for High-Intensity Beams in the CERN Proton Synchrotron

    CERN Document Server

    AUTHOR|(CDS)2082016; Benedikt, Michael

    With the discovery of the Higgs boson, the existence of the last missing piece of the Standard Model of particle physics (SM) was confirmed. However, even though very elegant, this theory is unable to explain, for example, the generation of neutrino masses, nor does it account for dark energy or dark matter. To shed light on some of these open questions, research in fundamental particle physics pursues two complimentary approaches. On the one hand, particle colliders working at the high-energy frontier, such as the Large Hadron Collider (LHC) at the European Organization for Nuclear Research (CERN), located in Geneva, Switzerland, are utilized to investigate the fundamental laws of nature. Alternatively, fixed target facilities require high-intensity beams to create a large flux of secondary particles to investigate, for example, rare particle decay processes, or to create neutrino beams. This thesis investigates limitations arising during the acceleration of high-intensity beams at the CERN Proton Synchrotro...

  16. Effects of high-intensity training on cardiovascular risk factors in pre- and postmenopausal women

    DEFF Research Database (Denmark)

    Mandrup Jensen, Camilla Maria; Egelund, Jon; Nyberg, Michael Permin

    2017-01-01

    BACKGROUND: Menopause is associated with increased risk of cardiovascular disease and the causal factors have been proposed to be the loss of estrogen and the subsequent alterations of the hormonal milieu. However, which factors that contribute to the deterioration of cardio-metabolic health...... and cardiovascular disease in late pre- and early postmenopausal women, matched by age and body composition, and investigate the effect of high-intensity training. METHODS: A 3-month high-intensity aerobic training intervention, involving healthy, non-obese, late pre- (n=40) and early postmenopausal (n=39) women...... insulin concentration during the oral glucose tolerance test (pCardiovascular risk factors are similar in late pre- and early postmenopausal women, matched by age and body composition, with the exception that postmenopausal women have higher HDL-C and LDL-C levels...

  17. High intensity metallic ion beam from an ecr ion source using the Mivoc method

    Energy Technology Data Exchange (ETDEWEB)

    Barue, C.; Canet, C.; Dupuis, M.; Flambard, J.L.; Leherissier, P.; Lemagnen, F. [Grand Accelerateur National d' Ions Lourds (GANIL), 14 - Caen (France); Jaffres, P.A. [Institut des Sciences de la Matiere et du Rayonnement, SIMRa, 14 - Cean (France)

    2000-07-01

    The MIVOC method has been successfully used at GANIL to produce a high intensity nickel beam with the ECR4 ion source: 20 {mu}A {sup 58}Ni{sup 11+} at 24 kV extraction voltage. This beam has been maintained for 8 days and accelerated up to 74.5 MeV/u by our cyclotrons with a mean intensity of 0.13 p{mu}A on target. This high intensity, required for experiment, led to the discovery of the doubly magic {sup 48}Ni isotope. Experimental setup, handling and off-line preparation using a residual gas analyzer are described in this report. The ion source behavior, performances and limitations are presented in the case of nickel and iron. The ionization efficiencies have been measured and compared to the oven method usually used at GANIL. (author)

  18. Current status of high-intensity focused ultrasound for the management of uterine adenomyosis

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Vincent Y. T. [Dept. of Obstetrics and Gynaecology, Queen Mary Hospital, The University of Hong Kong, Hong Kong (China)

    2017-04-15

    While high-intensity focused ultrasound has been used for some time in the management of uterine fibroids, its effectiveness and safety in managing adenomyosis is less well established. A literature review was performed of all eligible reports using this modality as a treatment for adenomyosis. Relevant publications were obtained from the PubMed electronic database from inception through March 2016. Eleven articles, including information from 1,150 treatments and follow-up data from 990 patients, were reviewed. High-intensity focused ultrasound appears to be effective and safe in the management of symptomatic adenomyosis, and can be considered as an alternative uterine-sparing option for women with this condition.

  19. Recovery of a soil under different vegetation one year after a high intensity wildfire

    Directory of Open Access Journals (Sweden)

    A. Martín

    2013-05-01

    Full Text Available Studies on soil recovery in fragile ecosystems following high intensity wildfires are scarce. The aim of the present investigation is to evaluate the impact of a high intensity wildfire in an ecosystem under different vegetation (shrubland and pinewood located at Vilardevós (Galicia, NW Spain and highly susceptible to suffer soil erosion due to the steep relief and high erositivity of the rainfall. Soil samples were collected from the A horizon (0-5 cm 1 year after the fire and soil quality was evaluated by analysis of several physical, chemical and biochemical properties measured in the fraction chemical properties > physical properties. The data also showed that the fire impact was different depending on the soil vegetation considered (shrubland and pinewood. Moreover, the data confirmed the slow soil recovery in this fragile ecosystem and, therefore, the need of adopting post-fire stabilisation and rehabilitation treatments in order to minimize the post-fire erosion and soil degradation.

  20. High intensity training improves exercise performance in elite women volleyball players during a competitive season

    DEFF Research Database (Denmark)

    Purkhús, Elisabeth; Krustrup, Peter; Mohr, Magni

    2016-01-01

    separated by 25 s of recovery), and the Yo-Yo Intermittent Recovery level 2 test (Yo-Yo IR2) followed by a-10 min rest period and the Yo-Yo IR1 test. Mean running distance during HIT-training in wk-1 was 152±4 m and increased (P... improved by 12.6 and 18.3% post-intervention, respectively, with greater (Ptraining performed as interval running improved agility, repeated sprint ability and high intensity intermittent exercise performance in elite......Elite women volleyball players (n=25; age; 19±5 yrs, height; 171±7 cm, weight; 63±10 kg; means±SD) volunteered to participate in the study. They were randomized into a high intensity training group (HIT; n=13) and a control group (CON; n=12). In addition to the normal team training and games, HIT...

  1. High-intensity running in English FA Premier League soccer matches

    DEFF Research Database (Denmark)

    Bradley, Paul S.; Sheldon, William; Wooster, Blake

    2009-01-01

    The aims of this study were to (1) determine the activity profiles of a large sample of English FA Premier League soccer players and (2) examine high-intensity running during elite-standard soccer matches for players in various playing positions. Twenty-eight English FA Premier League games were...... analysed during the 2005-2006 competitive season (n=370), using a multi-camera computerised tracking system. During a typical match, wide midfielders (3138 m, s=565) covered a greater distance in high-intensity running than central midfielders (2825 m, s= 73, P=0.04), full-backs (2605 m, s=387, P ....01), attackers (2341 m, s=575, P running distance was approximately 20% less than in the first 15-min period for wide midfielders (467 m, s=104 vs. 589 m, s=134, P

  2. High-intensity acoustics for military nonlethal applications: a lack of useful systems.

    Science.gov (United States)

    Jauchem, James R; Cook, Michael C

    2007-02-01

    There have been many previous claims of nonlethal acoustic weapon effects, mostly in the popular rather than the scientific literature. Anecdotal reports of extraordinary effects can make meaningful assessment and review of this area very difficult. Acoustics research has shown that the nonlethal weapon capabilities of audible sound generators have been grossly overstated. Although high-intensity infrasound significantly disrupted animal behavior in some experiments, the generation of such energy in a volume large enough to be of practical use is unlikely because of basic physical principles. On the basis of experimentation completed to date at a number of institutions, it seems unlikely that high-intensity acoustic energy in the audible, infrasonic, or low-frequency range can provide a device suitable for use as a nonlethal weapon.

  3. Photobiomodulation in laser surgery

    Science.gov (United States)

    Liu, Timon Cheng-Yi; Rong, Dong-Liang; Huang, Jin; Deng, Xiao-Yuan; Liu, Song-Hao

    2006-01-01

    Laser surgery provides good exposure with clear operating fields and satisfactory preliminary functional results. In contrast to conventional excision, it was found that matrix metalloproteinases and the tissue inhibitors of metalloproteinases -1 mRNA expression is higher, myofibroblasts appeared and disappeared slower in laser excision wounds. It has been suggested that the better anatomical and functional results achieved following laser cordectomy may be explained by the fact that such procedures result in better, more rapid healing processes to recover vocal cord for early glottic tumors and better. In this paper, the role of photobiomodulation in laser surgery will be discussed by the cultured monolayer normal human skin fibroblast model of the photobiomodulation of marginal irradiation of high intensity laser beam, the photobiomodulation related to the irradiated tissue, the biological information model of photobiomodulation and the animal models of laser surgery. Although high intensity laser beam is so intense that it destroys the irradiated cells or tissue, its marginal irradiation intensity is so low that there is photobiomodulation on non-damage cells to modulate the regeneration of partly damaged tissue so that the surgery of laser of different parameters results in different post-surgical recovery. It was concluded that photobiomodulation might play an important role in the long-term effects of laser surgery, which might be used to design laser surgery.

  4. Specificity of high-intensity intermittent action remains important to MMA athletes' physical conditioning: response to Paillard (2011).

    Science.gov (United States)

    Del Vecchio, Fabrício Boscolo; Franchini, Emerson

    2013-02-01

    This response to Paillard (2011) focuses on the intermittent nature of mixed martial arts (MMA). It also emphasizes that the main goal of MMA athletes is to win by knockout or submission and that these actions normally are high-intensity actions or preceded by high-intensity actions. Additionally, there is evidence that high-intensity intermittent exercise protocols are able to improve aerobic fitness. It is important only to adjust physical training to the athletes' techniques and tactics.

  5. Transrectal high-intensity focused ultrasound for the treatment of prostate cancer: Past, present, and future

    Directory of Open Access Journals (Sweden)

    Luigi Mearini

    2010-01-01

    Full Text Available Upon a review of recently published articles on high-intensity focused ultrasound (HIFU in the treatment of prostate cancer, we evaluated the current status of HIFU as a primary treatment option for localized prostate cancer and its use as salvage therapy when radiation failed. We also briefly discuss current issues in indications, definition of response, and finally the future of HIFU development.

  6. SPES: A new cyclotron-based facility for research and applications with high-intensity beams

    Science.gov (United States)

    Maggiore, M.; Campo, D.; Antonini, P.; Lombardi, A.; Manzolaro, M.; Andrighetto, A.; Monetti, A.; Scarpa, D.; Esposito, J.; Silvestrin, L.

    2017-06-01

    In 2016, Laboratori Nazionali di Legnaro (Italy) started the commissioning of a new accelerator facility based on a high-power cyclotron able to deliver proton beams up to 70 MeV of energy and 700 μA current. Such a machine is the core of the Selective Production of Exotic Species (SPES) project whose main goal is to provide exotics beam for nuclear and astrophysics research and to deliver high-intensity proton beams for medical applications and neutrons generator.

  7. Repeated high-intensity running and sprinting in elite women’s soccer competition

    OpenAIRE

    Gabbett, Tim J.; Wiig, Håvard; Spencer, Matt

    2013-01-01

    Background: To the authors’ knowledge, no study has investigated the concurrent repeated, high-intensity (RHIA) and repeated-sprint activity (RSA) of intermittent team-sport competition. Purpose: In this study, they report on the RSA of elite women’s football competition. In addition, they describe the nature of RHIA (eg, striding and sprinting activities) that involve a high energy cost and are associated with short (ie, ≤20 s) recovery periods. Methods: Thirteen elite women soccer players u...

  8. Moderate Altitude Affects High Intensity Running Performance in a Collegiate Women?s Soccer Game

    OpenAIRE

    Bohner Jonathan D.; Hoffman Jay R; McCormack William. P.; Scanlon Tyler C.; Townsend Jeremy R.; Stout Jeffrey R.; Fragala Maren S; Fukuda David H

    2015-01-01

    The effect of altitude on soccer game activity profiles was retrospectively examined in six NCAA Division I female soccer players. Comparisons were made between two matches played at sea level (SL) and one match played at a moderate altitude (1839 m). A 10-Hz global positioning system device was used to measure distance and velocity. The rate of total distance capacity (TDC) and high intensity running (HIR) as well as percent of time at HIR were evaluated. Significant differences were seen in...

  9. High-Intensity Nanosecond Pulsed Electric Field effects on Early Physiological Development in Arabidopsis thaliana

    OpenAIRE

    Wisuwat Songnuan; Phumin Kirawanich

    2011-01-01

    The influences of pulsed electric fields on early physiological development in Arabidopsis thaliana were studied. Inside a 4-mm electroporation cuvette, pre-germination seeds were subjected to high-intensity, nanosecond electrical pulses generated using laboratory-assembled pulsed electric field system. The field strength was varied from 5 to 20 kV.cm-1 and the pulse width and the pulse number were maintained at 10 ns and 100, respectively, corresponding to the specific t...

  10. High-intensity interval training and athletic performance in Taekwondo athletes.

    Science.gov (United States)

    Monks, Lynne; Seo, Myong-Won; Kim, Hyun-Bae; Jung, Hyun C; Song, Jong K

    2017-10-01

    The purpose of this study was to determine the effects of high-intensity interval training (HIIT) on athletic performance in Taekwondo athletes. Thirty-three male and female collegiate Taekwondo athletes were randomly divided into a HIIT group (N.=16) or a high-intensity continuous running (HICR) group (N.=17). The HIIT group undertook training of high-intensity sprints interspersed with active rest periods whilst the HICR group participated in high-intensity running for a continuous period. Both groups completed 11 sessions over 4 weeks. Physique, body composition, Wingate anaerobic test and VO2max test were measured. The vertical jump test, agility T-test and sit-ups were used to assess physical fitness. Repeated measures ANCOVAs with sex as a covariate were applied and significant level was set at 0.05. Following 11 sessions of training, significant improvements in anaerobic peak power (PHIIT group compared to HICR group. A greater improvement of aerobic capacity was observed in HIIT group (8.8%) compared to the HICR group (1.7%). In relation to physical fitness, the HIIT group improved in the vertical jump while the HICR group did not change. Both the HIIT and HICR groups showed greater improvements in T-test and sit-ups during the intervention period. This study shows the effectiveness of eleven sessions of HIIT in producing significant improvements in anaerobic capacity relevant to successful Taekwondo competition performance in collegiate Taekwondo athletes. This could inform the future planning of Taekwondo athletes' pre-competition training, specifically the influence of training intensity on anaerobic capacity.

  11. A Highly intense DC muon source, MuSIC and muon CLFV search

    Energy Technology Data Exchange (ETDEWEB)

    Hino, Y.; Kuno, Y.; Sato, A. [Department of Physics, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043 (Japan); Sakamoto, H. [Department of Physics, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043 (Japan); Research Center of Nuclear Physics, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Matsumoto, Y.; Tran, N.H.; Hashim, I.H. [Department of Physics, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043 (Japan); Fukuda, M.; Hayashida, Y. [Research Center of Nuclear Physics, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Ogitsu, T.; Yamamoto, A.; Yoshida, M. [High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan)

    2014-08-15

    MuSIC is a new muon facility, which provides the world's highest intense muon beam with continuous time structure at Research Center of Nuclear Physics (RCNP), Osaka University. It's intensity is designed to be 10{sup 8} muons per second with only 0.4 kW proton beam. Such a high intense muon beam is very important for searches of rare decay processes, for example search for the muon to electron conversion.

  12. Perspectives on high-intensity interval exercise for health promotion in children and adolescents

    Science.gov (United States)

    Bond, Bert; Weston, Kathryn L; Williams, Craig A; Barker, Alan R

    2017-01-01

    Physical activity lowers future cardiovascular disease (CVD) risk; however, few children and adolescents achieve the recommended minimum amount of daily activity. Accordingly, there is virtue in identifying the efficacy of small volumes of high-intensity exercise for health benefits in children and adolescents for the primary prevention of CVD risk. The purpose of this narrative review is to provide a novel overview of the available literature concerning high-intensity interval-exercise (HIIE) interventions in children and adolescents. Specifically, the following areas are addressed: 1) outlining the health benefits observed following a single bout of HIIE, 2) reviewing the role of HIIE training in the management of pediatric obesity, and 3) discussing the effectiveness of school-based HIIE training. In total, 39 HIIE intervention studies were included in this review. Based upon the available data, a single bout of high-intensity exercise provides a potent stimulus for favorable, acute changes across a range of cardiometabolic outcomes that are often superior to a comparative bout of moderate-intensity exercise (14 studies reviewed). HIIE also promotes improvements in cardiorespiratory fitness and cardiometabolic health status in overweight and obese children and adolescents (10 studies reviewed) and when delivered in the school setting (15 studies reviewed). We thus conclude that high-intensity exercise is a feasible and potent method of improving a range of cardiometabolic outcomes in children and adolescents. However, further work is needed to optimize the delivery of HIIE interventions in terms of participant enjoyment and acceptability, to include a wider range of health outcomes, and to control for important confounding variables (eg, changes in diet and habitual physical activity). Finally, research into the application of HIIE training interventions to children and adolescents of different ages, sexes, pubertal status, and sociocultural backgrounds is

  13. Numerical simulations of stripping effects in high-intensity hydrogen ion linacs

    Directory of Open Access Journals (Sweden)

    J.-P. Carneiro

    2009-04-01

    Full Text Available Numerical simulations of H^{-} stripping losses from blackbody radiation, electromagnetic fields, and residual gas have been implemented into the beam dynamics code TRACK. Estimates of the stripping losses along two high-intensity H^{-} linacs are presented: the Spallation Neutron Source linac currently being operated at Oak Ridge National Laboratory and an 8 GeV superconducting linac currently being designed at Fermi National Accelerator Laboratory.

  14. High intensity aerobic interval training improves peak oxygen consumption in patients with metabolic syndrome: CAT

    OpenAIRE

    Alexis Espinoza Salinas; Raúl Aguilera Eguía; Cristian Cofre Bolados; Edson Zafra Santos; Gustavo Pavéz Von Martens

    2014-01-01

    Introduction A number of cardiovascular risk factors characterizes the metabolic syndrome: insulin resistance (IR), low HDL cholesterol and high triglycerides. The aforementioned risk factors lead to elevated levels of abdominal adipose tissue, resulting in oxygen consumption deficiency. Purpose To verify the validity and applicability of using high intensity interval training (HIIT) in subjects with metabolic syndrome and to answer the following question: Can HIIT improve peak oxyg...

  15. High-intensity focused ultrasound to treat primary hyperparathyroidism: a feasibility study in four patients

    DEFF Research Database (Denmark)

    Kovatcheva, Roussanka D; Vlahov, Jordan D; Shinkov, Alexander D

    2010-01-01

    Many patients with primary hyperparathyroidism either decline or are not candidates for surgical parathyroidectomy. There are drawbacks to medical therapy as well as percutaneous ethanol injection as alternative therapies for primary hyperparathyroidism. Therefore, in this pilot study, our aim...... was to test the feasibility, safety, and efficacy of a newly developed noninvasive high-intensity focused ultrasound (HIFU) technique for the nonsurgical management of primary hyperparathyroidism....

  16. Luminescent rise times of inorganic phosphors excited by high intensity ultraviolet light.

    Science.gov (United States)

    Anderson, R J; Ricchio, S G

    1973-11-01

    The relative delay between excitation and luminescence was measured for a number of common inorganic phosphors using short, high intensity excitation pulses. The delays were found to be much shorter than anticipated; on the basis of low intensity pulsed luminescence measurements and were found to be extremely intensity-dependent. Both the luminescence rise and decay times were found to be intensitydependent as well, with the luminescence pulse waveform tending to approach the exciting pulse at the higher excitation intensities.

  17. Short-term effects of implemented high intensity shoulder elevation during computer work

    OpenAIRE

    Larsen, Mette K; Samani, Afshin; Madeleine, Pascal; Olsen, Henrik B; S?gaard, Karen; Holtermann, Andreas

    2009-01-01

    Abstract Background Work-site strength training sessions are shown effective to prevent and reduce neck-shoulder pain in computer workers, but difficult to integrate in normal working routines. A solution for avoiding neck-shoulder pain during computer work may be to implement high intensity voluntary contractions during the computer work. However, it is unknown how this may influence productivity, rate of perceived exertion (RPE) as well as activity and rest of neck-shoulder muscles during c...

  18. Effects of high-intensity physical training on muscle fiber characteristics in poststroke patients.

    Science.gov (United States)

    Andersen, Jesper L; Jørgensen, Jørgen R; Zeeman, Peter; Bech-Pedersen, Daniel T; Sørensen, Jane; Ara, Ignacio; Andersen, Lars L

    2017-11-01

    Stroke is a leading cause of disability worldwide. High-intensity physical training can improve muscle strength and gait speed, but adaptive mechanisms at the muscle cellular level are largely unknown. Outpatients with poststroke hemiparesis participated in a 3-month rehabilitation program combining high-intensity strength and body-weight supported treadmill-training. Biopsies sampled bilaterally from vastus lateralis muscles, before, after, and at 1-year follow-up after intervention, were analyzed for fiber size, type, and capillarization. At baseline, paretic lower limbs had smaller muscle fiber size and lower type I and IIA and higher type IIX percentages than nonparetic lower limbs. Paretic lower limbs had increased type IIA fibers after training. At follow-up, no difference between the lower limbs remained. Although high-intensity training appeared not to induce changes in fiber size or capillarization, increased type IIA fiber percentages may contribute to muscle power and endurance, which is crucial for functional capacity. Muscle Nerve 56: 954-962, 2017. © 2016 Wiley Periodicals, Inc.

  19. Protection of Lotus Seedpod Proanthocyanidins on Organs and Tissues under High-intensity Excercise.

    Science.gov (United States)

    Mengyan, Zhang

    2015-01-01

    Lotus seedpod proanthocyanidins (LSPC) as a kind of polyphenols is widely used in medicines, cosmetics, health products. High-intensity exercise can cause damage to the body's organs and tissues. Different doses of LSPC is given to mice to check the function of protect effect to the body's organs and tissues under high-intensity exercise. The hemoglobin (HB) content, red blood cell (RBC) number and white blood cell (WBC) number were tested for mice after exercise. The activity of superoxide dismutase (SOD) and the contents of glutathione (GSH) and malondialdehyde (MDA) in muscle and viscera were evaluated. The result showed that LSPC can effectively reduce inflammation reaction in the body of mice with high intensity exercise, alleviate oxidative stress-induced injury of tissues and organs, and execute protective function on skeletal muscle and cardiac muscle. And the LSPC could enhance myocardial anti-oxygen and enzymatic activity which suggests the protective effects of resveratrol against exercise-induced myocardial damage in mice.

  20. Carbohydrate ingestion during prolonged high-intensity intermittent exercise: impact on affect and perceived exertion.

    Science.gov (United States)

    Backhouse, S H; Ali, A; Biddle, S J H; Williams, C

    2007-10-01

    This study was designed to determine the effects of ingesting a carbohydrate (CHO) solution on affective states and rating of perceived exertion (RPE) during prolonged intermittent high-intensity exercise. Seventeen male soccer players completed a prolonged intermittent high-intensity exercise protocol for 90 min on two occasions, separated by at least 7 days. Participants consumed either a 6.4% CHO (0.6 g/kg body mass (BM)/h) or an artificially sweetened placebo (PLA) solution immediately before (8 mL/kg BM) and every 15 min (3 mL/kg BM) during exercise in a double-blind, counterbalanced design. Pleasure-displeasure, perceived activation, RPE and plasma glucose concentration was assessed. The results showed that compared with the CHO trial, perceived activation were lower in the placebo trial during the last 30 min of exercise and this was accompanied by lowered plasma glucose concentrations. In the CHO trial, RPE was maintained in the last 30 min of exercise but carried on increasing in the PLA trial. Therefore, CHO ingestion during prolonged high-intensity exercise appears to elicit an enhanced perceived activation profile that may impact upon task persistence and performance. This finding is in addition to the physiological and metabolic benefits of the exogenous energy supply.

  1. Benefits of High-Intensity Intensive Care Unit Physician Staffing under the Affordable Care Act

    Directory of Open Access Journals (Sweden)

    Sachin Logani

    2011-01-01

    Full Text Available The Affordable Care Act signed into law by President Obama, with its value-based purchasing program, is designed to link payment to quality processes and outcomes. Treatment of critically ill patients represents nearly 1% of the gross domestic product and 25% of a typical hospital budget. Data suggest that high-intensity staffing patterns in the intensive care unit (ICU are associated with cost savings and improved outcomes. We evaluate the literature investigating the cost-effectiveness and clinical outcomes of high-intensity ICU physician staffing as recommended by The Leapfrog Group (a consortium of companies that purchase health care for their employees and identify ways to overcome barriers to nationwide implementation of these standards. Hospitals that have implemented the Leapfrog initiative have demonstrated reductions in mortality and length of stay and increased cost savings. High-intensity staffing models appear to be an immediate cost-effective way for hospitals to meet the challenges of health care reform.

  2. Effect of β-alanine supplementation on high-intensity exercise performance.

    Science.gov (United States)

    Harris, Roger C; Stellingwerff, Trent

    2013-01-01

    Carnosine is a dipeptide of β-alanine and L-histidine found in high concentrations in skeletal muscle. Combined with β-alanine, the pKa of the histidine imidazole ring is raised to ∼6.8, placing it within the muscle intracellular pH high-intensity exercise transit range. Combination with β-alanine renders the dipeptide inert to intracellular enzymic hydrolysis and blocks the histidinyl residue from participation in proteogenesis, thus making it an ideal, stable intracellular buffer. For vegetarians, synthesis is limited by β-alanine availability; for meat-eaters, hepatic synthesis is supplemented with β-alanine from the hydrolysis of dietary carnosine. Direct oral β-alanine supplementation will compensate for low meat and fish intake, significantly raising the muscle carnosine concentration. This is best achieved with a sustained-release formulation of β-alanine to avoid paresthesia symptoms and decreasing urinary spillover. In humans, increased levels of carnosine through β-alanine supplementation have been shown to increase exercise capacity and performance of several types, particularly where the high-intensity exercise range is 1-4 min. β-Alanine supplementation is used by athletes competing in high-intensity track and field cycling, rowing, swimming events and other competitions. Copyright © 2013 Nestec Ltd., Vevey/S. Karger AG, Basel.

  3. [Effect of high-intensity alternating magnetic field 
on viscosity of sheep blood].

    Science.gov (United States)

    Tao, Pengxian; Wu, Xiangyang; Zhao, Lingzhi; Wang, Feng; Xia, Qi; Peng, Yan; Gao, Bingren

    2017-12-28

    To explore the changes of blood viscosity in high-intensity alternating magnetic field and the mechanisms.
 Methods: Five adult sheep were randomly selected and the blood samples were placed in high-intensity alternating magnetic field. Before and after exposure, the blood samples were taken and divided into 2 groups: a control group and a magnetic field group. The blood rheology and transmission electron microscopy (TEM) were performed.
 Results: Compared to the control group, the high shear viscosity of whole blood was decreased in the magnetic field group (P<0.05); the whole blood low shear viscosity and plasma viscosity were also decreased (both P<0.01). TEM showed the changes in red blood cell morphology and the double concave disc curvature. The radian of double concave disc and cell volume in the magnetic field group was larger than those in the control group.
 Conclusion: The high intensity alternating magnetic field may affect the distribution of surface charge and molecular current in blood cells, which in turn decrease the aggregation of cells and the blood viscosity.

  4. High intensity aerobic interval training improves peak oxygen consumption in patients with metabolic syndrome: CAT

    Directory of Open Access Journals (Sweden)

    Alexis Espinoza Salinas

    2014-06-01

    Full Text Available Introduction A number of cardiovascular risk factors characterizes the metabolic syndrome: insulin resistance (IR, low HDL cholesterol and high triglycerides. The aforementioned risk factors lead to elevated levels of abdominal adipose tissue, resulting in oxygen consumption deficiency. Purpose To verify the validity and applicability of using high intensity interval training (HIIT in subjects with metabolic syndrome and to answer the following question: Can HIIT improve peak oxygen consumption? Method The systematic review "Effects of aerobic interval training on exercise capacity and metabolic risk factors in individuals with cardiometabolic disorders" was analyzed. Results Data suggests high intensity aerobic interval training increases peak oxygen consumption by a standardized mean difference of 3.60 mL/kg-1/min-1 (95% confidence interval, 0.28-4.91. Conclusion In spite of the methodological shortcomings of the primary studies included in the systematic review, we reasonably conclude that implementation of high intensity aerobic interval training in subjects with metabolic syndrome, leads to increases in peak oxygen consumption.

  5. Potential Universal Application of High-intensity Interval Training from Athletes and Sports Lovers to Patients.

    Science.gov (United States)

    Azuma, Koichiro; Matsumoto, Hideo

    2017-06-25

    Recently, high-intensity interval training (HIIT) has received much attention as a promising exercise option not only to improve aerobic fitness, but also to prevent and improve lifestyle-related diseases. Epidemiological studies have shown that the exercise volume, as determined by the product of exercise intensity, duration, and frequency, has been shown to be important for improvements in muscle mitochondrial activity and subsequent improvements in aerobic fitness, insulin sensitivity, and metabolic variables. Therefore, continuous moderate-intensity training has been widely recommended. On the other hand, the main contributor of HIIT to improvements in aerobic fitness and metabolic variables is its high-intensity nature, and many recent studies have shown results favoring HIIT when compared with conventional continuous training, despite its shorter exercise duration and smaller exercise volume. In this review, we aim to show the possible universal application of HIIT in a hospital setting, where athletes, sports lovers, and patients have sought medical advice and have the opportunity to undergo detailed evaluations, including an exercise stress test. For athletes, HIIT is mandatory to achieve further improvements in aerobic fitness. For patients, though higher levels of motivation and careful evaluation are required, the time constraints of HIIT are smaller and both aerobic and resistance training can be expected to yield favorable results because of the high-intensity nature of HIIT.

  6. Effects of myofascial release after high-intensity exercise: a randomized clinical trial.

    Science.gov (United States)

    Arroyo-Morales, Manuel; Olea, Nicolas; Martinez, Manuel; Moreno-Lorenzo, Carmen; Díaz-Rodríguez, Lourdes; Hidalgo-Lozano, Amparo

    2008-03-01

    The usefulness of massage as a recovery method after high-intensity exercise has yet to be established. We aimed to investigate the effects of whole-body massage on heart rate variability (HRV) and blood pressure (BP) after repeated high-intensity cycling exercise under controlled and standardized pretest conditions. The study included 62 healthy active individuals. After baseline measurements, the subjects performed standardized warm-up exercises followed by three 30-second Wingate tests. After completing the exercise protocol, the subjects were randomly assigned to a massage (myofascial release) or placebo (sham treatment with disconnected ultrasound and magnetotherapy equipment) group for a 40-minute recovery period. Holter recording and BP measurements were taken after exercise protocol and after the intervention. After the exercise protocol, both groups showed a significant decrease in normal-to-normal interval, HRV index, diastolic BP (P > .001), and low-frequency domain values (P = .006). After the recovery period, HRV index (P = .42) and high-frequency (HF) (P = .94) values were similar to baseline levels in the massage group, whereas the HRV index tended (P = .05) to be lower and the HF was significantly (P Myofascial release massage favors the recovery of HRV and diastolic BP after high-intensity exercise (3 Wingate tests) to preexercise levels.

  7. Repeated High Intensity Bouts with Long Recovery: Are Bicarbonate or Carbohydrate Supplements an Option?

    Directory of Open Access Journals (Sweden)

    Thomas Stöggl

    2014-01-01

    Full Text Available The effects of varying recovery modes and the influence of preexercise sodium bicarbonate and carbohydrate ingestion on repeated high intensity performance, acid-base response, and recovery were analyzed in 12 well-trained males. They completed three repeated high intensity running bouts to exhaustion with intervening recovery periods of 25 min under the following conditions: sodium bicarbonate, active recovery (BIC; carbohydrate ingestion, active recovery (CHO; placebo ingestion, active recovery (ACTIVE; placebo ingestion, passive recovery (PASSIVE. Blood lactate (BLa, blood gases, heart rate, and time to exhaustion were collected. The three high intensity bouts had a duration of 138±9, 124±6, and 121±6 s demonstrating a decrease from bout 1 to bout 3. Supplementation strategy had no effect on performance in the first bout, even with differences in pH and bicarbonate (HCO3-. Repeated sprint performance was not affected by supplementation strategy when compared to ACTIVE, while PASSIVE resulted in a more pronounced decrease in performance compared with all other interventions. BIC led to greater BLa, pH, and HCO3- values compared with all other interventions, while for PASSIVE the opposite was found. BLa recovery was lowest in PASSIVE; recovery in pH, and HCO3- was lower in PASSIVE and higher in BIC.

  8. Can harms associated with high-intensity drinking be reduced by increasing the price of alcohol?

    Science.gov (United States)

    Byrnes, Joshua; Shakeshaft, Anthony; Petrie, Dennis; Doran, Christopher

    2013-01-01

    Increasing the price of alcohol is consistently shown to reduce the average level of consumption. However, the evidence for the effect of increasing the price on high-intensity drinking is both limited and equivocal. The aim of this analysis is to estimate the effect of changes in price on patterns of consumption. Self-reported patterns of alcohol consumption and demographic data were obtained from the Australian National Drug Strategy Household Surveys, conducted in 2001, 2004 and 2007. A pooled three-stage least-squares estimator was used to simultaneously model the impact of the price on the frequency (measured in days) of consuming no, low, moderate and high quantities of alcohol. A 1% increase in the price of alcohol was associated with a statistically significant increase of 6.41 days per year on which no alcohol is consumed (P ≤ 0.049), and a statistically significant decrease of 7.30 days on which 1-4 standard drinks are consumed (P ≤ 0.021). There was no statistically significant change for high or moderate-intensity drinking. For Australia, and countries with a similar pattern of predominant high-intensity drinking, taxation policies that increase the price of alcohol and are very efficient at decreasing harms associated with reduced average consumption may be relatively inefficient at decreasing alcohol harms associated with high-intensity drinking. © 2012 Australasian Professional Society on Alcohol and other Drugs.

  9. HIGH INTENSITY EXERCISE AND FLEXIBILITY OF THE LOWER LIMBS: DOSE-EFFECT STUDY

    Directory of Open Access Journals (Sweden)

    João Rafael Valentim-Silva

    Full Text Available ABSTRACT Introduction: Sports scientists have been studying the phenomenon involving different types of exercises and their influence on other activities. Stretching exercises have a negative influence on muscular strength and power output, as do high intensity or long duration cardiovascular training. Nevertheless, several studies have found the opposite to be true Nevertheless, few investigations have studied the opposite. Objective: To determine whether high intensity power exercise influences muscular flexibility in an acute manner. Methods: A sample of forty-three male and female young adults aged between 18 and 28 years, with a mean age of 22.88 + 3.04 years, who have practiced physical activity for at least six months. To determine flexibility, the sit-and-reach test was used. For the high intensity training, a 45º leg press was used. A 10-rep movement was performed at 85% of 1 RM, in both pre- and post-tests. Statistic analysis was conducted using the ANOVA and Scheffer's post-hoc tests, with a level of significance for differences of < 0.05. Results: Comparison of the pre- and post-tests proved to be statistically significant from the baseline from the fourth to the seventh repetitions. Conclusion: Strength exercises at 85% of 1RM seem to significantly increase range of motion in an acute manner, and the growth of this range of motion has a dose-effect response.

  10. Training for intense exercise performance: high-intensity or high-volume training?

    Science.gov (United States)

    Laursen, P B

    2010-10-01

    Performance in intense exercise events, such as Olympic rowing, swimming, kayak, track running and track cycling events, involves energy contribution from aerobic and anaerobic sources. As aerobic energy supply dominates the total energy requirements after ∼75s of near maximal effort, and has the greatest potential for improvement with training, the majority of training for these events is generally aimed at increasing aerobic metabolic capacity. A short-term period (six to eight sessions over 2-4 weeks) of high-intensity interval training (consisting of repeated exercise bouts performed close to or well above the maximal oxygen uptake intensity, interspersed with low-intensity exercise or complete rest) can elicit increases in intense exercise performance of 2-4% in well-trained athletes. The influence of high-volume training is less discussed, but its importance should not be downplayed, as high-volume training also induces important metabolic adaptations. While the metabolic adaptations that occur with high-volume training and high-intensity training show considerable overlap, the molecular events that signal for these adaptations may be different. A polarized approach to training, whereby ∼75% of total training volume is performed at low intensities, and 10-15% is performed at very high intensities, has been suggested as an optimal training intensity distribution for elite athletes who perform intense exercise events. © 2010 John Wiley & Sons A/S.

  11. Effects of high-intensity exercise on leptin and testosterone concentrations in well-trained males.

    Science.gov (United States)

    Kraemer, Robert R; Durand, Robert J; Acevedo, Edmund O; Johnson, Lisa G; Synovitz, Linda B; Kraemer, Ginger R; Gimpel, Terry; Castracane, V Daniel

    2003-08-01

    A number of investigations have examined the effect of exercise on leptin concentrations, because leptin is associated with obesity, satiety, and reproductive function. High-intensity exercise is known to increase testosterone, an inhibitor of leptin. The objective of the study was to determine whether the leptin responses to a progressive, intermittent exercise protocol were related to serum testosterone concentrations. Most previous studies have examined leptin responses to low or moderately high exercise intensities. A second objective was to determine whether leptin responses were different than previous experiments using intermittent moderate and high-intensity exercise. Well-trained runners completed strenuous intermittent exercise consisting of treadmill running at 60, 75, 90, and 100% VO(2 max) and a subsequent resting control trial was also conducted. There were significant increases in mean serum levels of leptin and testosterone with both quickly returning to baseline during recovery, but no relationship between the two hormones was found. After examining individual data for both hormones, it was discovered that subjects could be classified as leptin responders or nonresponders, whereas testosterone increased in all subjects. Responders had elevated serum leptin levels at baseline and exhibited increases after high-intensity exercise, whereas nonresponders did not show changes in leptin during exercise. Data suggest testosterone levels do not acutely affect leptin responses to exercise or 1-h of recovery. Moreover, varied leptin responses to intense exercise in comparable well-trained runners was observed and was associated with baseline leptin concentrations.

  12. Joint Cooling does not Hinder Athletic Performance during High-intensity Intermittent Exercise.

    Science.gov (United States)

    Kim, H; Lee, D; Choi, H-M; Park, J

    2016-07-01

    We examined the effects of ankle and knee joint cooling on 20-m sprint times and maximal vertical jump heights during high-intensity intermittent exercise. 21 healthy collegiate male basketball (n=14) and handball players (n=7) underwent 3 experimental sessions. Each session consisted of four 15-min quarters of high-intensity intermittent exercises including various intensities of 20-m shuttle running and jumping. A 20-min bilateral joint cooling (ankle, knee, or control-no cooling: in a counterbalanced order) was applied before quarters 1 and 3. After joint cooling, no warm-up activity other than the exercise protocol was given. The 20-m sprint times and maximal vertical jump heights in each experimental session were recorded at baseline (prior to quarter-1) and during each quarter. To test joint cooling effects over time, we performed 3×5 mixed model ANOVAs. Neither ankle nor knee joint cooling changed 20-m sprint times (F8,280=1.45; p=0.18) or maximal vertical jump heights (F8,280=0.76; p=0.64). However, a trend was observed in which joint cooling immediately decreased (quarters 1 and 3) but active warm-up for approximately 20 min improved 20-min sprint times (quarters 2 and 4). Our study suggests that athletic performance such as sprinting and jumping are not altered by joint cooling applied prior to or during high-intensity intermittent exercise. © Georg Thieme Verlag KG Stuttgart · New York.

  13. High-Intensity Interval Training in Normobaric Hypoxia Leads to Greater Body Fat Loss in Overweight/Obese Women than High-Intensity Interval Training in Normoxia

    Directory of Open Access Journals (Sweden)

    Alba Camacho-Cardenosa

    2018-02-01

    Full Text Available A moderate hypoxic stimulus is considered a promising therapeutic modality for several pathological states including obesity. There is scientific evidence suggesting that when hypoxia and physical activity are combined, they could provide benefits for the obese population. The aim of the present study was to investigate if exposure to hypoxia combined with two different protocols of high-intensity interval exercise in overweight/obese women was more effective compared with exercise in normoxia. Study participants included 82 overweight/obese women, who started a 12 week program of 36 sessions, and were randomly divided into four groups: (1 aerobic interval training in hypoxia (AitH; FiO2 = 17.2%; n = 13, (2 aerobic interval training in normoxia (AitN; n = 15, (3 sprint interval training in hypoxia (SitH; n = 15, and (4 sprint interval training in normoxia (SitN; n = 18. Body mass, body mass index, percentage of total fat mass, muscle mass, basal metabolic rate, fat, and carbohydrate oxidation, and fat and carbohydrate energy were assessed. Outcomes were measured at baseline (T1, after 18 training sessions (T2, 7 days after the last session (T3, and 4 weeks after the last session (T4. The fat mass in the SitH group was significantly reduced compared with the SitN group from T1 to T3 (p < 0.05 and from T1 to T4 (p < 0.05 and muscle mass increased significantly from T1 to T4 (p < 0.05. Fat mass in the AitH group decreased significantly (p < 0.01 and muscle mass increased (p = 0.022 compared with the AitN group from T1 to T4. All training groups showed a reduction in the percentage of fat mass, with a statistically significant reduction in the hypoxia groups (p < 0.05. Muscle mass increased significantly in the hypoxia groups (p < 0.05, especially at T4. While fat oxidation tended to increase and oxidation of carbohydrates tended to decrease in both hypoxia groups, the tendency was reversed in the normoxia groups. Thus, high-intensity interval

  14. SALIVARY CORTISOL RESPONSES AND PERCEIVED EXERTION DURING HIGH INTENSITY AND LOW INTENSITY BOUTS OF RESISTANCE EXERCISE

    Directory of Open Access Journals (Sweden)

    Alison D. Egan

    2004-03-01

    Full Text Available The purpose of this study was to measure the salivary cortisol response to different intensities of resistance exercise. In addition, we wanted to determine the reliability of the session rating of perceived exertion (RPE scale to monitor resistance exercise intensity. Subjects (8 men, 9 women completed 2 trials of acute resistance training bouts in a counterbalanced design. The high intensity resistance exercise protocol consisted of six, ten-repetition sets using 75% of one repetition maximum (RM on a Smith machine squat and bench press exercise (12 sets total. The low intensity resistance exercise protocol consisted of three, ten-repetition sets at 30% of 1RM of the same exercises as the high intensity protocol. Both exercise bouts were performed with 2 minutes of rest between each exercise and sessions were repeated to test reliability of the measures. The order of the exercise bouts was randomized with least 72 hours between each session. Saliva samples were obtained immediately before, immediately after and 30 mins following each resistance exercise bout. RPE measures were obtained using Borg's CR-10 scale following each set. Also, the session RPE for the entire exercise session was obtained 30 minutes following completion of the session. There was a significant 97% increase in the level of salivary cortisol immediately following the high intensity exercise session (P<0.05. There was also a significant difference in salivary cortisol of 145% between the low intensity and high intensity exercise session immediately post-exercise (P<0.05. The low intensity exercise did not result in any significant changes in cortisol levels. There was also a significant difference between the session RPE values for the different intensity levels (high intensity 7.1 vs. low intensity 1.9 (P<0.05. The intraclass correlation coefficient for the session RPE measure was 0.95. It was concluded that the session RPE method is a valid and reliable method of

  15. Laser Beam Caustic Measurement with Focal Spot Analyser

    DEFF Research Database (Denmark)

    Olsen, Flemming Ove; Gong, Hui; Bagger, Claus

    2005-01-01

    In industrial applications of high power CO2-lasers the caustic characteristics of the laser beam have great effects on the performance of the lasers. A welldefined high intense focused spot is essential for reliable production results. This paper presents a focal spot analyser that is developed...... for measuring the beam profiles of focused high power CO2-lasers....

  16. Proton radiography of magnetic field produced by ultra-intense laser irradiating capacity-coil target

    CERN Document Server

    Wang, W W; Chen, J; Cai, H B; He, S K; Zhou, W M; Shan, L Q; Lu, F; Wu, Y C; Hong, W; Liu, D X; Bi, B; Zhang, F; Xue, F B; Li, B Y; Zhang, B; He, Y L; He, W; Jiao, J L; Dong, K G; Zhang, F Q; Deng, Z G; Zhang, Z M; Cui, B; Han, D; Zhou, K N; Wang, X D; Zhao, Z Q; Cao, L F; Zhang, B H; He, X T; Gu, Y Q

    2014-01-01

    Ultra-intense ultra-short laser is firstly used to irradiate the capacity-coil target to generate magnetic field. The spatial structure and temporal evolution of huge magnetic fields were studied with time-gated proton radiography method. A magnetic flux density of 40T was measured by comparing the proton deflection and particle track simulations. Although the laser pulse duration is only 30fs, the generated magnetic field can last for over 100 picoseconds. The energy conversion efficiency from laser to magnetic field can reach as high as ~20%. The results indicate that tens of tesla (T) magnetic field could be produced in many ultra intense laser facilities around the world, and higher magnetic field could be produced by picosecond lasers.

  17. Patterns of high-intensity drinking among young adults in the United States: A repeated measures latent class analysis.

    Science.gov (United States)

    Patrick, Megan E; Terry-McElrath, Yvonne M; Schulenberg, John E; Bray, Bethany C

    2017-11-01

    Using a national sample of young adults, this study identified latent classes of alcohol use including high-intensity drinking (10+ drinks) from ages 18 to 25/26, and explored associations between time-invariant covariates measured at age 18 and class membership. Longitudinal data from the national Monitoring the Future study were available for 1078 individuals (51% female) first surveyed as 12th grade students in 2005-2008, and followed through modal age 25/26. Repeated measures latent class analysis was used to identify latent classes based on self-reported alcohol use: no past 30-day drinking, 1-9 drinks per occasion in the past 2weeks, and 10+ drinks per occasion. Four latent classes of alcohol use from ages 18 to 25/26 were identified: (1) Non-Drinkers (21%); (2) Legal Non-High-Intensity Drinkers (23%); (3) Persistent Non-High-Intensity Drinkers (40%); and (4) High-Intensity Drinkers (16%). Membership in the High-Intensity Drinkers class was characterized by higher than average probabilities of high-intensity drinking at all ages, with the probability of high-intensity drinking increasing between ages 18 and 21/22. Both gender and race/ethnicity significantly differentiated class membership, whereas neither parental education (a proxy for socioeconomic status) nor college plans at 12th grade showed significant associations. More than one in seven individuals who were seniors in high school experienced a long-term pattern of high-intensity drinking lasting into middle young adulthood. Young adult high-intensity drinking is often preceded by high-intensity drinking in high school, suggesting the importance of screening and prevention for high-intensity drinking during adolescence. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Laser weapons

    Science.gov (United States)

    Tsipis, K.

    1981-12-01

    The potential for deploying lasers as an effective antimissile system is assessed. High intensity and precise collimation are noted as essential for lasers as weapons, although size and material properties determine the actual performance. Gas-dynamic, electron, and chemical lasers are reviewed as prime weapons candidates. Space-, ground-, and ship-based uses are considered; each demands precision pointing, involving movable mirrors, target tracking and condition sensors, and central processing for target choice, along with large capacity power generation and storage. Laser propagation in the atmosphere is degraded by absorption, scattering, thermal blooming, turbulence (causes diffraction), and plasma formation ahead of the beam. Different modes of damaging missiles are reviewed, and it is found that mirrored surfaces, ablative coatings, and fluid layers have significant abilities to protect a missile in-flight. Destroying an ICBM in the boost phase is calculated to require a one million MW generator, far beyond current power engineering capabilities. Conventional weapons are viewed as more effective than lasers, although high energy laser research may have definite applications in areas such as chemical engineering

  19. Nanomedical science and laser-driven particle acceleration: promising approaches in the prethermal regime

    Science.gov (United States)

    Gauduel, Y. A.

    2017-05-01

    A major challenge of spatio-temporal radiation biomedicine concerns the understanding of biophysical events triggered by an initial energy deposition inside confined ionization tracks. This contribution deals with an interdisciplinary approach that concerns cutting-edge advances in real-time radiation events, considering the potentialities of innovating strategies based on ultrafast laser science, from femtosecond photon sources to advanced techniques of ultrafast TW laser-plasma accelerator. Recent advances of powerful TW laser sources ( 1019 W cm-2) and laser-plasma interactions providing ultra-short relativistic particle beams in the energy domain 5-200 MeV open promising opportunities for the development of high energy radiation femtochemistry (HERF) in the prethermal regime of secondary low-energy electrons and for the real-time imaging of radiation-induced biomolecular alterations at the nanoscopic scale. New developments would permit to correlate early radiation events triggered by ultrashort radiation sources with a molecular approach of Relative Biological Effectiveness (RBE). These emerging research developments are crucial to understand simultaneously, at the sub-picosecond and nanometric scales, the early consequences of ultra-short-pulsed radiation on biomolecular environments or integrated biological entities. This innovating approach would be applied to biomedical relevant concepts such as the emerging domain of real-time nanodosimetry for targeted pro-drug activation and pulsed radio-chimiotherapy of cancers.

  20. Effects of High Intensity Interval Training on Fat Mass Parameters in Adolescents.

    Science.gov (United States)

    Camacho-Cardenosa, Alba; Brazo-Sayavera, Javier; Camacho-Cardenosa, Marta; Marcos-Serrano, Marta; Timón, Rafael; Olcina, Guillermo

    2016-11-21

    Childhood and adolescence are key to the development of chronic disease stages, the distribution of fat an important factor in this regard. The aim of the study was to evaluate the effects on fat parameters of a high intensity program developed in adolescents during physical education classes. In 2013, 35 school-age children of Cáceres taken part in this study divided into two groups. The high-intensity group performed for 8 weeks, 4-6 sets of 20 seconds at maximal intensity with a ratio effort / recovery of 1: 3 to 1: 1. The other group, developed continuous aerobic exercise during the same time. It conducted an assessment of fat mass before and after the training program. Repeated measures ANOVA test was used to observe that there were no statistically significant differences. Continuous aerobic training group showed statistically significant differences in intra-group analysis in the percentage of fat mass trunk (Pre: 15.66 ± 4.16 vs Post: 16.95 ± 4.03; +1, 29%; p = 0.04) and the percentage of total fat (Pre: 21.58 ± 3.93 / Post: 22.34 ± 3.70; p = 0.05). Statistically significant differences were not found in the analysis between-groups in any of the studied variables. The training program high intensity physical activity at school carried out during physical education classes did not improve fat mass parameters evaluated. However, maintaining these parameters could be a good result during the development of this stage, where an increase of these occurs.

  1. Beetroot Juice Supplementation Improves High-Intensity Intermittent Type Exercise Performance in Trained Soccer Players

    Directory of Open Access Journals (Sweden)

    Jean Nyakayiru

    2017-03-01

    Full Text Available It has been shown that nitrate supplementation can enhance endurance exercise performance. Recent work suggests that nitrate ingestion can also increase intermittent type exercise performance in recreational athletes. We hypothesized that six days of nitrate supplementation can improve high-intensity intermittent type exercise performance in trained soccer players. Thirty-two male soccer players (age: 23 ± 1 years, height: 181 ± 1 m, weight: 77 ± 1 kg, playing experience: 15.2 ± 0.5 years, playing in the first team of a 2nd or 3rd Dutch amateur league club participated in this randomized, double-blind cross-over study. All subjects participated in two test days in which high-intensity intermittent running performance was assessed using the Yo-Yo IR1 test. Subjects ingested nitrate-rich (140 mL; ~800 mg nitrate/day; BR or a nitrate-depleted beetroot juice (PLA for six subsequent days, with at least eight days of wash-out between trials. The distance covered during the Yo-Yo IR1 was the primary outcome measure, while heart rate (HR was measured continuously throughout the test, and a single blood and saliva sample were collected just prior to the test. Six days of BR ingestion increased plasma and salivary nitrate and nitrite concentrations in comparison to PLA (p < 0.001, and enhanced Yo-Yo IR1 test performance by 3.4 ± 1.3% (from 1574 ± 47 to 1623 ± 48 m; p = 0.027. Mean HR was lower in the BR (172 ± 2 vs. PLA trial (175 ± 2; p = 0.014. Six days of BR ingestion effectively improves high-intensity intermittent type exercise performance in trained soccer players.

  2. RELATIONSHIP BETWEEN BLOOD LACTATE AND HYPERVENTILATION DURING HIGH-INTENSITY CONSTANT-LOAD EXERCISE IN HEAT

    Directory of Open Access Journals (Sweden)

    T. Chiba

    2011-09-01

    Full Text Available The purpose of this study was to examine the relationship between hyperventilation and increase in blood lactate during high-intensity constant-load exercise in heat and normal conditions. Seven male volunteers exercised for 10 min on a cycle ergometer at 80%·VO2max in heat (40ºC, 50%relative humidity: HT and normal conditions (20ºC, 50% relative humidity: CON. Oxygen uptake, carbon dioxide output, ventilation, blood lactate and blood electrolytes (K , Na , Cl− were measured in HT and CON. We found that ventilation was significantly higher during exercise in HT compared with CON (p<0.05 and RER tends to be higher in HT than in CON. Blood lactate was significantly higher at 3 min during exercise in HT compared with CON (5.96 ± 0.57 mEq·l-1 5.00 ± 0.28 mEq·l-1, p<0.05. Change in strong ion difference [∆SID = (∆K ∆Na − (∆Cl− ∆La−], which affects ∆HCO3− in blood significantly, was lower at 5 min during exercise in HT compared with in CON (p<0.05. These results suggest that hyperventilation during exercise in heat would induce lower HCO3− in blood and consequently would result in an increase in blood lactate at an earlier time during high-intensity exercise in heat. It was concluded that hyperventilation during short-term high-intensity exercise in heat is temporarily associated with an increase in blood lactate.

  3. Absence of Respiratory Muscle Fatigue in High-Intensity Continuous or Interval Cycling Exercise.

    Science.gov (United States)

    Kurti, Stephanie P; Smith, Joshua R; Emerson, Sam R; Castinado, Kenneth M; Harms, Craig A

    2015-11-01

    Respiratory muscle fatigue (RMF) occurs during prolonged exercise (∼15-20 minutes) at >85% V[Combining Dot Above]O2max. However, RMF has been reported to occur in ∼3-6 minutes in various modes of exercise at a high intensity. It is not known if continuous cycling exercise vs. repeated bouts of high-intensity interval training (HIT) at >85% V[Combining Dot Above]O2max will lead to RMF. We hypothesized that RMF would occur after a constant load test and would be present before end exercise in an HIT protocol. Eight moderately active healthy men (21.7 ± 1.7 years; 181.3 ± 5.2 cm; 81.3 ± 2.3 kg) completed a V[Combining Dot Above]O2max test on a cycle ergometer. Subjects then completed 2 bouts of HIT (7 × 1 minute, 2-minute recovery between intervals) and 3 bouts of continuous exercise (CE) tests at 90% of peak power (determined from an incremental exercise test to exhaustion). Maximal inspiratory pressure (PIMAX) and expiratory pressure (PEMAX) were measured pre- and post-exercise for both HIT and CE and after each interval during HIT. Decreases in postexercise PIMAX and PEMAX compared with baseline were used to determine RMF. There were no differences (p > 0.05) in PIMAX or PEMAX pre- to post-exercise for HIT (PIMAX pre: 134 ± 51, post: 135 ± 50 cmH2O; PEMAX pre: 143 ± 41, post: 148 ± 46 cmH2O) or CE (PIMAX pre: 135 ± 54, post: 133 ± 52 cmH2O; PEMAX pre: 146 ± 46, post: 148 ± 46 cmH2O) indicating RMF was not present following CE and HIT. These data suggest that repeated high-intensity cycling exercise at 90% peak power in a CE or HIT protocol does not lead to RMF.

  4. Experience Corps Baltimore: Exploring the Stressors and Rewards of High-intensity Civic Engagement.

    Science.gov (United States)

    Varma, Vijay R; Carlson, Michelle C; Parisi, Jeanine M; Tanner, Elizabeth K; McGill, Sylvia; Fried, Linda P; Song, Linda H; Gruenewald, Tara L

    2015-12-01

    Experience Corps (EC) represents a high-intensity, intergenerational civic engagement activity where older adults serve as mentors and tutors in elementary schools. Although high-intensity volunteer opportunities are designed to enhance the health and well being of older adult volunteers, little is known about the negative and positive aspects of volunteering unique to intergenerational programs from the volunteer's perspective. Stressors and rewards associated with volunteering in EC were explored in 8 focus group discussions with 46 volunteers from EC Baltimore. Transcripts were coded for frequently expressed themes. Participants reported stressors and rewards within 5 key domains: intergenerational (children's problem behavior, working with and helping children, observing/facilitating improvement or transformation in a child, and developing a special connection with a child); external to EC (poor parenting and children's social stressors); interpersonal (challenges in working with teachers and bonding/making social connections); personal (enjoyment, self-enhancement/achievement, and being/feeling more active); and structural (satisfaction with the structural elements of the EC program). Volunteers experienced unique intergenerational stressors related to children's problem behavior and societal factors external to the EC program. Overall, intergenerational, interpersonal, and personal rewards from volunteering, as well as program structure may have balanced the stress associated with volunteering. A better understanding of stressors and rewards from high-intensity volunteer programs may enhance our understanding of how intergenerational civic engagement volunteering affects well being in later life and may inform project modifications to maximize such benefits for future volunteers and those they serve. © The Author 2014. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e

  5. High intensity exercise enhances platelet reactivity to shear stress and coagulation during and after exercise.

    Science.gov (United States)

    Ikarugi, Hideo; Shibata, Masashi; Shibata, Shiori; Ishii, Hiromitsu; Taka, Tomomi; Yamamoto, Junichiro

    2003-01-01

    Platelets play a crucial role in the pathogenesis of acute cardiac events, such as angina, myocardial infarction and sudden death. It is believed that regular low-intensity exercise can reduce, while high-intensity exercise may provoke acute cardiac events. The aim of the present study was to investigate the effect of acute exercise both at low and high intensities on the ventilatory threshold (VT), platelet reactivity and coagulation before and after exercise. Platelet reactivity and coagulation were measured under flow condition, using native blood, by hemostatometry. Seven healthy young men (age: 20-29 years) performed bicycle ergometer exercise for 30 min at intensities of 90% (Ex-VT90% or approximately 55% VO(2max)) and 130% (Ex-VT130% or 80% VO(2max)) of individual VT. Blood cell counts, hematocrit, blood lactic acid and plasma catecholamine levels were slightly but significantly increased after Ex-VT90% and markedly after Ex-VT130% after 30 min exercise. Subsequent to the exercise, the elevated blood cell counts decreased to the resting levels both at Ex-VT90% and at Ex-VT130%. Platelet reactivity to shear stress and dynamic coagulation were significantly enhanced immediately and 30 min after Ex-130%VT. In contrast, no significant changes occurred in those of Ex-90%VT. The present study suggests that high-intensity exercise-induced platelet hyperreactivity and hypercoagulable state may pose an increased risk for acute, sometimes fatal cardiac event. On the other hand, our findings support the view that low-intensity exercise does not present a risk of thrombosis. Copyright 2003 S. Karger AG, Basel

  6. Increased high-intensity activity in elite Australian football finals matches.

    Science.gov (United States)

    Aughey, Robert J

    2011-09-01

    Australian football (AF) is a highly intermittent sport, requiring athletes to accelerate hundreds of times with repeated bouts of high-intensity running (HIR). Players aim to be in peak physical condition for finals, with anecdotal evidence of increased speed and pressure of these games. However, no data exists on the running demands of finals games, and therefore the aim of this study was to compare the running demands of finals to regular season games with matched players and opponents. Player movement was recorded by GPS at 5 Hz and expressed per period of the match (rotation), for total distance, high-intensity running (HIR, 4.17-10.00 m·s-1) and maximal accelerations (2.78-10.00 m·s-2). All data was compared for regular season and finals games and the magnitude of effects was analyzed with the effect size (ES) statistic and expressed with confidence intervals. Each of the total distance (11%; ES: 0.78 ± 0.30), high-intensity running distance (9%; ES: 0.29 ± 0.25) and number of maximal accelerations (97%; ES: 1.30 ± 0.20) increased in finals games. The largest percentage increases in maximal accelerations occurred from a commencement velocity of between 3-4 (47%; ES: 0.56 ± 0.21) and 4-5 m·s-1 (51%; ES: 0.72 ± 0.26), and with <19 s between accelerations (53%; ES: 0.63 ± 0.27). Elite AF players nearly double the number of maximal accelerations in finals compared with regular season games. This large increase is superimposed on requirements to cover a greater total distance and spend more time at high velocity during finals games. Players can be effectively conditioned to cope with these increased demands, even during a long competitive season.

  7. Locomotor muscle fatigue does not alter oxygen uptake kinetics during high-intensity exercise

    Directory of Open Access Journals (Sweden)

    James Hopker

    2016-10-01

    Full Text Available The slow component (VO2sc that develops during high-intensity aerobic exercise is thought to be strongly associated with locomotor muscle fatigue. We sought to experimentally test this hypothesis by pre-fatiguing the locomotor muscles used during subsequent high-intensity cycling exercise. Over two separate visits, eight healthy male participants were asked to either perform a non-metabolically stressful 100 intermittent drop-jumps protocol (pre fatigue condition or rest for 33 minutes (control condition according to a random and counterbalanced order. Locomotor muscle fatigue was quantified with 6-second maximal sprints at a fixed pedaling cadence of 90 rev·min-1. Oxygen kinetics and other responses (heart rate, capillary blood lactate concentration and rating of perceived exertion, RPE were measured during two subsequent bouts of 6 min cycling exercise at 50% of the delta between the lactate threshold and VO2max determined during a preliminary incremental exercise test. All tests were performed on the same cycle ergometer. Despite significant locomotor muscle fatigue (P = 0.03, the VO2sc was not significantly different between the pre fatigue (464 ± 301 mL·min-1 and the control (556 ± 223 mL·min-1 condition (P = 0.50. Blood lactate response was not significantly different between conditions (P = 0.48 but RPE was significantly higher following the pre-fatiguing exercise protocol compared with the control condition (P < 0.01 suggesting higher muscle recruitment. These results demonstrate experimentally that locomotor muscle fatigue does not significantly alter the VO2 kinetic response to high intensity aerobic exercise, and challenge the hypothesis that the VO2sc is strongly associated with locomotor muscle fatigue.

  8. The effects of high intensity interval training in normobaric hypoxia on aerobic capacity in basketball players.

    Science.gov (United States)

    Czuba, Miłosz; Zając, Adam; Maszczyk, Adam; Roczniok, Robert; Poprzęcki, Stanisław; Garbaciak, Wiesław; Zając, Tomasz

    2013-12-18

    The aim of the present study was to evaluate the efficacy of 3-week high intensity interval training in normobaric hypoxia (IHT) on aerobic capacity in basketball players. Twelve male well trained basketball players, randomly divided into a hypoxia (H) group (n=6; age: 22±1.6 years; VO2max: 52.6±3.9 ml/kg/min; body height - BH: 188.8±6.1 cm; body mass - BM: 83.9±7.2 kg; % of body fat - FAT%: 11.2±3.1%), and a control (C) group (n=6; age: 22±2.4 years; VO2max: 53.0±5.2 ml/kg/min; BH: 194.3 ± 6.6 cm; BM: 99.9±11.1 kg; FAT% 11.0±2.8 %) took part in the study. The training program applied during the study was the same for both groups, but with different environmental conditions during the selected interval training sessions. For 3 weeks, all subjects performed three high intensity interval training sessions per week. During the interval training sessions, the H group trained in a normobaric hypoxic chamber at a simulated altitude of 2500 m, while the group C performed interval training sessions under normoxia conditions also inside the chamber. Each interval running training sessions consisted of four to five 4 min bouts at 90% of VO2max velocity determined in hypoxia (vVO2max-hyp) for the H group and 90% of velocity at VO2max determined in normoxia for the group C. The statistical post-hoc analysis showed that the training in hypoxia caused a significant (pintermittent hypoxic training protocol with high intensity intervals (4 to 5 × 4 min bouts at 90% of vVO2max-hyp) is an effective training means for improving aerobic capacity at sea level in basketball players.

  9. Evaluate thermal lesion using Nakagami imaging for monitoring of high-intensity focused ultrasound

    Science.gov (United States)

    Zhang, Siyuan; Li, Chong; Zhou, Fanyu; Wang, Supin; Wan, Mingxi

    2017-03-01

    High-intensity focused ultrasound (HIFU) is currently being developed as a noninvasive technique for the treatment of cancer located in various tissues. Cavitation microbubbles (MBs) have been potential to aid treatment while the acoustic posterior shadowing effects of MBs influence the accuracy for defining the location and range of ablated thermal lesions during focused ultrasound surgery when using ultrasonic monitoring imaging. This work explored the feasibility of using ultrasonic Nakagami imaging to evaluate the ablated region induced by focused ultrasound exposures at different acoustic power levels in transparent tissue-mimicking phantoms.

  10. Reactor target from metal chromium for "pure" high-intensive artificial neutrino source

    Science.gov (United States)

    Gavrin, V. N.; Kozlova, Yu. P.; Veretenkin, E. P.; Logachev, A. V.; Logacheva, A. I.; Lednev, I. S.; Okunkova, A. A.

    2017-01-01

    The paper presents the first results of development of manufacturing technology of metallic chromium targets from highly enriched isotope 50Cr for irradiation in a high flux nuclear reactor to obtain a compact high intensity neutrino source with low content of radionuclide impurities and minimum losses of enriched isotope. The main technological stages are the hydrolysis of chromyl fluoride, the electrochemical reduction of metallic chromium, the hot isostatic pressing of chromium powder and the electrical discharge machining of chromium bars. The technological stages of hot isostatic pressing of chromium powder and of electrical discharge machining of Cr rods have been tested.

  11. Influence of Ramadan Fasting on Anaerobic Performance and Recovery Following Short time High Intensity Exercise

    OpenAIRE

    Umid Karli; Alpay Guvenc; Alper Aslan; Tahir Hazir; Caner Acikada

    2007-01-01

    The aim of this study was to investigate the effects of Ramadan fasting on anaerobic power and capacity and the removal rate of lactate after short time high intensity exercise in power athletes. Ten male elite power athletes (2 wrestlers, 7 sprinters and 1 thrower, aged 20-24 yr, mean age 22.30 ± 1.25 yr) participated in this study. The subjects were tested three times [3 days before the beginning of Ramadan (Pre-RF), the last 3 days of Ramadan (End-RF) and the last 3 days of the 4th week af...

  12. Effects and Sustainability of a 13-Day High-Intensity Shock Microcycle in Soccer

    Directory of Open Access Journals (Sweden)

    Patrick Wahl

    2014-06-01

    Full Text Available The preseason in soccer is a short period of 6-8 weeks where conditional abilities, technical and tactical elements need to be trained. Therefore, time is lacking to perform long term preparation periods for different abilities, especially endurance training. There is evidence that the implementation of high-intensity shock microcycles in preseason training could be one way to improve physical performance in a short period of time. Therefore, the purpose of the present study was to examine the effects and the sustainability of a high-intensity shock microcycle on soccer specific performance. Over 2 weeks, 12 male soccer players (26.1 ± 4.5 years performed 12 high-intensity training (HIT sessions in addition to their usual training. Before (pre, 6 days (6d and 25 days (25d after training, subjects performed Counter Movement Jump (CMJ, Repeated-Sprint Ability (RSA test and Yo-Yo Intermittent Recovery Test Level 2 (YYIR2. Mean sprint time (RSAMean (cohen’s d = -1.15, percentage decrement score (RSAIndex (cohen’s d = -1.99 and YYIR2 (cohen’s d = +1.92 improved significantly from pre to 6d. 25d after, values showed a significant reduction for YYIR2 (cohen’s d = -0.81 and small to moderate but not significant increase for RSAMean (cohen’s d = +0.37 and RSAIndex (cohen’s d = +0.7 compared to 6d values. Small but no significant increases were found for CMJ (cohen’s d = +0.33 and no significant and substantial changes were found for RSABest (cohen’s d = -0.07 from pre to 6d. For competitive soccer players, block periodization of HIT offers a promising way to largely improve RSA and YYIR2 in a short period of time. Despite moderate to large decreases in RSAIndex and YYIR2 performance in the 19 day period without HIT, values still remained significantly higher 25d after the last HIT session compared to pre-values. However, it might be necessary to include isolated high-intensity sessions after a HIT training block in order to maintain the

  13. Design concept of radiation control system for the high intensity proton accelerator facility

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, Yukihiro; Ikeno, Koichi; Akiyama, Shigenori; Harada, Yasunori [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2002-11-01

    Description is given for the characteristic radiation environment for the High Intensity Proton Accelerator Facility and the design concept of the radiation control system of it. The facility is a large scale accelerator complex consisting of high energy proton accelerators carrying the highest beam intensity in the world and the related experimental facilities and therefore provides various issues relevant to the radiation environment. The present report describes the specifications for the radiation control system for the facility, determined in consideration of these characteristics. (author)

  14. New initiatives on lepton flavor violation and neutrino oscillation with high intense muon and neutrino sources

    CERN Document Server

    Kuno, Yoshitaka; Pakvasa, Sandip

    2002-01-01

    The area of physics involving muons and neutrinos has become exciting in particle physics. Using their high intensity sources, physicists undertake, in various ways, extensive searches for new physics beyond the Standard Model, such as tests of supersymmetric grand unification (SUSY-GUT) and precision measurements of the muon and neutrino properties, which will in future extend to ambitious studies such as determination of the three-generation neutrino mixing matrix elements and CP violation in the lepton sector. The physics of this field is advancing, with potential improvements of the source

  15. Effect of moderate- and high-intensity acute exercise on appetite in obese individuals

    DEFF Research Database (Denmark)

    Martins, Catia; Stensvold, Dorthe; Finlayson, Graham

    2015-01-01

    /obese volunteers. Participants were assigned to the control, MICC, HIIC, and S-HIIC conditions, 1 wk apart, in a counterbalanced order. Exercise was performed 1 h after a standard breakfast. An ad libitum test lunch was served 3 h after breakfast. Fasting/postprandial plasma samples of insulin, acylated ghrelin......, hunger or fullness ratings, EI, or food reward. CONCLUSIONS: Our findings suggest that, in overweight/obese individuals, isocaloric bouts of moderate- or high-intensity exercise lead to a similar appetite response. This strengthens previous findings in normal-weight individuals that acute exercise, even...

  16. High-Intensity Training Improves Exercise Performance in Elite Women Volleyball Players During a Competitive Season.

    Science.gov (United States)

    Purkhús, Elisabeth; Krustrup, Peter; Mohr, Magni

    2016-11-01

    Purkhús, E, Krustrup, P, and Mohr, M. High-intensity training improves exercise performance in elite women volleyball players during a competitive season. J Strength Cond Res 30(11): 3066-3072, 2016-Elite women volleyball players (n = 25; mean ± SD: age, 19 ± 5 years; height, 171 ± 7 cm; weight, 63 ± 10 kg) volunteered to participate in the study. They were randomized into a high-intensity training (HIT; n = 13) group and a control (CON; n = 12) group. In addition to the normal team training and games, HIT performed 6-10 × 30-seconds all-out running intervals separated by 3-minute recovery periods 3 times per week during a 4-week in-season period whereas CON only completed the team training sessions and games. Preintervention and postintervention, all players completed the arrowhead agility test (AAT), a repeated sprint test (RST; 5 × 30 meters separated by 25 seconds of recovery), and the Yo-Yo Intermittent Recovery level 2 test (Yo-Yo IR2) followed by a-10 minute rest period and the Yo-Yo IR1 test. Mean running distance during HIT in week 1 was 152 ± 4 m and increased (p ≤ 0.05) by 4.6% (159 ± 3 m) in week 4. The AAT performance improved (p ≤ 0.05) by 2.3% (18.87 ± 0.97-18.44 ± 1.06 seconds) and RST by 4.3% postintervention in the HIT group only. Baseline RST fatigue index was 7.0 ± 2.9 and 6.2 ± 5.0% in HIT and CON, respectively, but was lowered (p ≤ 0.05) to 2.7 ± 3.0% posttraining in HIT and remained unaltered in CON (5.5 ± 5.0%). In HIT, Yo-Yo IR2 and Yo-Yo IR1 performance improved by 12.6 and 18.3% postintervention, respectively, with greater (p ≤ 0.05) Yo-yo IR1 change scores than in CON. In conclusion, additional high-intensity in-season training performed as interval running improved agility, repeated sprint ability, and high-intensity intermittent exercise performance in elite women volleyball players.

  17. Perspectives on high-intensity interval exercise for health promotion in children and adolescents

    Directory of Open Access Journals (Sweden)

    Bond B

    2017-11-01

    Full Text Available Bert Bond,1 Kathryn L Weston,2 Craig A Williams,1 Alan R Barker1 1Children’s Health and Exercise Research Centre, Sport and Health Sciences, College of Life and Environmental Sciences, University of Exeter, Exeter, UK 2School of Health and Social Care, Teesside University, Middlesbrough, UK Abstract: Physical activity lowers future cardiovascular disease (CVD risk; however, few children and adolescents achieve the recommended minimum amount of daily activity. Accordingly, there is virtue in identifying the efficacy of small volumes of high-intensity exercise for health benefits in children and adolescents for the primary prevention of CVD risk. The purpose of this narrative review is to provide a novel overview of the available literature concerning high-intensity interval-exercise (HIIE interventions in children and adolescents. Specifically, the following areas are addressed: 1 outlining the health benefits observed following a single bout of HIIE, 2 reviewing the role of HIIE training in the management of pediatric obesity, and 3 discussing the effectiveness of school-based HIIE training. In total, 39 HIIE intervention studies were included in this review. Based upon the available data, a single bout of high-intensity exercise provides a potent stimulus for favorable, acute changes across a range of cardiometabolic outcomes that are often superior to a comparative bout of moderate-intensity exercise (14 studies reviewed. HIIE also promotes improvements in cardiorespiratory fitness and cardiometabolic health status in overweight and obese children and adolescents (10 studies reviewed and when delivered in the school setting (15 studies reviewed. We thus conclude that high-intensity exercise is a feasible and potent method of improving a range of cardiometabolic outcomes in children and adolescents. However, further work is needed to optimize the delivery of HIIE interventions in terms of participant enjoyment and acceptability, to include a

  18. Similar health benefits of endurance and high-intensity interval training in obese children

    OpenAIRE

    Ana Carolina Corte de Araujo; Hamilton Roschel; Andreia Rossi Picanço; Danilo Marcelo Leite do Prado; Sandra Mara Ferreira Villares; Ana Lúcia de Sá Pinto; Bruno Gualano

    2013-01-01

    Purpose: To compare two modalities of exercise training (i.e., Endurance Training [ET] and High-Intensity Interval Training [HIT]) on health-related parameters in obese children aged between 8 and 12 years. Methods: Thirty obese children were randomly allocated into either the ET or HIT group. The ET group performed a 30 to 60-minute continuous exercise at 80% of the peak heart rate (HR). The HIT group training performed 3 to 6 sets of 60-s sprint at 100% of the peak velocity interspersed by ...

  19. Influence of time of day on reactions to cycling at a fixed high intensity.

    OpenAIRE

    Reilly, T; Baxter, C.

    1983-01-01

    The circadian cycle in all-out competitive performance may be due to changes in motivational drive to tolerate strenuous exercise rather than to rhythms in maximal physiological functions. This experiment explored the hypothesis that a fixed relative loading of high intensity aerobic effort could be sustained for longer in the evening compared with the morning. Eight females cycled to exhaustion at 95% VO2 max at 06.30 h. and at 22.00 h. after a 5 min, moderate load of 40% VO2 max. Oral tempe...

  20. Analysis of a high intensity shear zone between overlapping fiber ends in a polymer matrix composite

    DEFF Research Database (Denmark)

    Lindgreen, Britta

    2008-01-01

    The formation of high intensity shear zones in a glass fiber reinforced thermoplast is studied numerically. The thermoplast is characterized by a finite strain elastic-viscoplastic constitutive relation and the calculations are carried out using a dynamic finite element program where plane strain...... that develop as the highly deformed region approaches the limit resulting from network stiffening in the polymer. A simple analysis assuming periodicity is included in order to study the mechanical behaviour of the polymer matrix between fiber ends with long overlap....