WorldWideScience

Sample records for high-energy photons electrons

  1. Production of Entangled X-Ray Photon Pairs by High Energy Electrons

    OpenAIRE

    Ispirian, K. A.; Ispiryan, M. K.

    2009-01-01

    Without developing a correct theory, the rate of the production of entangled photon pairs in the X-ray region by high energy electrons is estimated for experimental parameters used in a few experiments on X-ray parametric down conversion. Taking into account the need for X-ray entangled X-ray photons, it is proposed to begin the experimental study of such mechanism of nonlinear X-ray optics before the launch of the X-ray free electron lasers.

  2. Electromagnetic cascade in high-energy electron, positron, and photon interactions with intense laser pulses

    Science.gov (United States)

    Bulanov, S. S.; Schroeder, C. B.; Esarey, E.; Leemans, W. P.

    2013-06-01

    The interaction of high-energy electrons, positrons, and photons with intense laser pulses is studied in head-on collision geometry. It is shown that electrons and/or positrons undergo a cascade-type process involving multiple emissions of photons. These photons can consequently convert into electron-positron pairs. As a result charged particles quickly lose their energy developing an exponentially decaying energy distribution, which suppresses the emission of high-energy photons, thus reducing the number of electron-positron pairs being generated. Therefore, this type of interaction suppresses the development of the electromagnetic avalanche-type discharge, i.e., the exponential growth of the number of electrons, positrons, and photons does not occur in the course of interaction. The suppression will occur when three-dimensional effects can be neglected in the transverse particle orbits, i.e., for sufficiently broad laser pulses with intensities that are not too extreme. The final distributions of electrons, positrons, and photons are calculated for the case of a high-energy e-beam interacting with a counterstreaming, short intense laser pulse. The energy loss of the e-beam, which requires a self-consistent quantum description, plays an important role in this process, as well as provides a clear experimental observable for the transition from the classical to quantum regime of interaction.

  3. Comparison of analytical and Monte Carlo calculations of multi-photon effects in bremsstrahlung emission by high-energy electrons

    DEFF Research Database (Denmark)

    Mangiarotti, Alessio; Sona, Pietro; Ballestrero, Sergio

    2012-01-01

    Approximate analytical calculations of multi-photon effects in the spectrum of total radiated energy by high-energy electrons crossing thin targets are compared to the results of Monte Carlo type simulations. The limits of validity of the analytical expressions found in the literature are establi...

  4. Comparison of analytical and Monte Carlo calculations of multi-photon effects in bremsstrahlung emission by high-energy electrons

    Energy Technology Data Exchange (ETDEWEB)

    Mangiarotti, A. [Laboratorio de Instrumentacao e Fisica Experimental de Particulas, Coimbra (Portugal); Departamento de Fisica, Faculdade de Ciencias e Tecnologia da Universidade de Coimbra, Coimbra (Portugal); Sona, P., E-mail: pietro.sona@fi.infn.it [Dipartimento di Fisica e Astronomia, Universita degli Studi di Firenze, Polo Scientifico, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); INFN, Sezione di Firenze (Italy); Ballestrero, S. [Department of Physics University of Johannesburg, Johannesburg (South Africa); CERN PH/ADT, Geneve (Switzerland); Uggerhoj, U.I.; Andersen, K.K. [Department of Physics and Astronomy, University of Aarhus, Aarhus (Denmark)

    2012-10-15

    Approximate analytical calculations of multi-photon effects in the spectrum of total radiated energy by high-energy electrons crossing thin targets are compared to the results of Monte Carlo type simulations. The limits of validity of the analytical expressions found in the literature are established. The separate contributions to spectral distortion of electromagnetic processes other than bremsstrahlung are also studied in detail.

  5. Target, purging magnet and electron collector design for scanned high-energy photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Roger; Aasell, Mats; Naefstadius, Peder; Brahme, Anders [Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, PO Box 260, S-171 76 Stockholm (Sweden)

    1998-05-01

    A new method for producing very narrow and intense 50 MV bremsstrahlung beams with a half-width as low as 35 mm at a distance of 1 m from the target is presented. Such a beam is well suited for intensity modulation using scanned photon beams. An algorithm has been developed to minimize the width of the bremsstrahlung beam generated in a multilayer target by varying the individual layer thicknesses and atomic numbers under given constraints on the total target thickness and the mean energy of the transmitted electrons. Under such constraints the narrowest possible bremsstrahlung beam is obtained with a target composed of layers of monotonically increasing atomic number starting with the lowest possible value at the entrance side where the electrons impinge. It is also shown that the narrowest photon beam profile is associated with the highest possible forward photon yield. To be able to use the optimized target clinically it is desirable to be able to collect and stop all the electrons that are transmitted through the target. The electrons are most efficiently collected if they are kept close together, i.e. by minimizing the multiple scatter of the electrons and consequently the half-width of the generated bremsstrahlung beam. This is achieved by a thin low-atomic-number target. A dedicated electron stopper has been developed and integrated with the purging magnet. When the electron stopper is combined with a purging magnet, a primary photon collimator and a multileaf collimator, almost all of the transmitted electrons and their associated bremsstrahlung contamination can effectively be collected. The narrow photon beams from thin low-atomic-number targets have the additional advantage of producing the hardest and most penetrative photon spectrum possible, which is ideal for treating large deep-seated tumours. (author)

  6. Results on the Coherent Interaction of High Energy Electrons and Photons in Oriented Single Crystals

    CERN Document Server

    Apyan, A.; Badelek, B.; Ballestrero, S.; Biino, C.; Birol, I.; Cenci, P.; Connell, S.H.; Eichblatt, S.; Fonseca, T.; Freund, A.; Gorini, B.; Groess, R.; Ispirian, K.; Ketel, T.J.; Kononets, Yu.V.; Lopez, A.; Mangiarotti, A.; van Rens, B.; Sellschop, J.P.F.; Shieh, M.; Sona, P.; Strakhovenko, V.; Uggerhoj, E.; Uggerhj, Ulrik Ingerslev; Unel, G.; Velasco, M.; Vilakazi, Z.Z.; Wessely, O.; Kononets, Yu.V.

    2005-01-01

    The CERN-NA-59 experiment examined a wide range of electromagnetic processes for multi-GeV electrons and photons interacting with oriented single crystals. The various types of crystals and their orientations were used for producing photon beams and for converting and measuring their polarisation. The radiation emitted by 178 GeV unpolarised electrons incident on a 1.5 cm thick Si crystal oriented in the Coherent Bremsstrahlung (CB) and the String-of-Strings (SOS) modes was used to obtain multi-GeV linearly polarised photon beams. A new crystal polarimetry technique was established for measuring the linear polarisation of the photon beam. The polarimeter is based on the dependence of the Coherent Pair Production (CPP) cross section in oriented single crystals on the direction of the photon polarisation with respect to the crystal plane. Both a 1 mm thick single crystal of Germanium and a 4 mm thick multi-tile set of synthetic Diamond crystals were used as analyzers of the linear polarisation. A birefringence ...

  7. Laser-Driven Very High Energy Electron/Photon Beam Radiation Therapy in Conjunction with a Robotic System

    Directory of Open Access Journals (Sweden)

    Kazuhisa Nakajima

    2014-12-01

    Full Text Available We present a new external-beam radiation therapy system using very-high-energy (VHE electron/photon beams generated by a centimeter-scale laser plasma accelerator built in a robotic system. Most types of external-beam radiation therapy are delivered using a machine called a medical linear accelerator driven by radio frequency (RF power amplifiers, producing electron beams with an energy range of 6–20 MeV, in conjunction with modern radiation therapy technologies for effective shaping of three-dimensional dose distributions and spatially accurate dose delivery with imaging verification. However, the limited penetration depth and low quality of the transverse penumbra at such electron beams delivered from the present RF linear accelerators prevent the implementation of advanced modalities in current cancer treatments. These drawbacks can be overcome if the electron energy is increased to above 50 MeV. To overcome the disadvantages of the present RF-based medical accelerators, harnessing recent advancement of laser-driven plasma accelerators capable of producing 1-GeV electron beams in a 1-cm gas cell, we propose a new embodiment of the external-beam radiation therapy robotic system delivering very high-energy electron/photon beams with an energy of 50–250 MeV; it is more compact, less expensive, and has a simpler operation and higher performance in comparison with the current radiation therapy system.

  8. Experimental determination of the effective point of measurement of cylindrical ionization chambers for high-energy photon and electron beams.

    Science.gov (United States)

    Huang, Yanxiao; Willomitzer, Christian; Zakaria, Golam Abu; Hartmann, Guenther H

    2010-01-01

    Measurements of depth-dose curves in water phantom using a cylindrical ionization chamber require that its effective point of measurement is located at the measuring depth. Recommendations for the position of the effective point of measurement with respect to the central axis valid for high-energy electron and photon beams are given in dosimetry protocols. According to these protocols, the use of a constant shift P(eff) is currently recommended. However, this is still based on a very limited set of experimental results. It is therefore expected that an improved knowledge of the exact position of the effective point of measurement will further improve the accuracy of dosimetry. Recent publications have revealed that the position of the effective point of measurement is indeed varying with beam energy, field size and also with chamber geometry. The aim of this study is to investigate whether the shift of P(eff) can be taken to be constant and independent from the beam energy. An experimental determination of the effective point of measurement is presented based on a comparison between cylindrical chambers and a plane-parallel chamber using conventional dosimetry equipment. For electron beams, the determination is based on the comparison of halfvalue depth R(50) between the cylindrical chamber of interest and a well guarded plane-parallel Roos chamber. For photon beams, the depth of dose maximum, d(max), the depth of 80% dose, d(80), and the dose parameter PDD(10) were used. It was again found that the effective point of measurement for both, electron and photon beams Dosimetry, depends on the beam energy. The deviation from a constant value remains very small for photons, whereas significant deviations were found for electrons. It is therefore concluded that use of a single upstream shift value from the centre of the cylindrical chamber as recommended in current dosimetry protocols is adequate for photons, however inadequate for accurate electron beam dosimetry.

  9. Treatment of the electrons-photons cascade in the high energy gamma transport; Traitement de la cascade electrons - photons dans le transport des gammas de haute energie

    Energy Technology Data Exchange (ETDEWEB)

    Riz, D

    1999-10-01

    The electrons-photons cascade is an important phenomena occurring in gamma transport. This phenomena called also Bremsstrahlung happens whenever electrons, produced in a photon-atom interaction, trigger emission of photons while slowing down in the matter. Some previous calculations have shown that in particular circumstances, a flux of photons going through a lead plate can be multiplied by 3 when Bremsstrahlung is taken into account. This work is dedicated to a new method developed in CEA to take into account Bremsstrahlung in any gamma transport code using multigroup constants. An electron or a positron produced by an incident photon {gamma} will move till it has lost all its energy in collisions or in emissions of Bremsstrahlung {gamma}'. The path of the electron is short so all the Bremsstrahlung {gamma}' are assumed to be produced at the point of creation of the electron or positron. The result of this method is the knowledge of a transfer probability {gamma}{yields}{gamma}' that can be used in classical gamma transport codes. (A.C.)

  10. A study of Rhizophora spp wood phantom for dosimetric purposes using high-energy photon and electron beams.

    Science.gov (United States)

    Banjade, D P; Tajuddin, A A; Shukri, A

    2001-09-01

    Previous scattering and depth-dose investigations involving use of the Malaysian hardwood Rhizophora spp have shown this medium to produce good agreement with measurements made in water. Present study extends the comparison, now including measurements of percentage depth-dose made for photons at 6MV and 5 and 12MeV electron beams. For the 6 MV photon and 5 MeV electron beams, discrepancies between percentage depth-dose for Rhizophora spp and water, at all depths, are found to be within 2.6 and 2.4% respectively. At 12 MeV electron energies, measured percentage depth-doses in Rhizophora spp beyond 3.5cm depth are found to be in significant discord with those for water. The absorbed dose in water measured in Rhizophora spp at d(max) for all three beams produces discrepancies of no more than 1.1% when compared with measurements made in water.

  11. A study of Rhizophora spp wood phantom for dosimetric purposes using high-energy photon and electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Banjade, D.P. E-mail: dpbl4007@stud.usm.my; Tajuddin, A.A.; Shukri, A

    2001-09-01

    Previous scattering and depth-dose investigations involving use of the Malaysian hardwood Rhizophora spp have shown this medium to produce good agreement with measurements made in water. Present study extends the comparison, now including measurements of percentage depth-dose made for photons at 6 MV and 5 and 12 MeV electron beams. For the 6 MV photon and 5 MeV electron beams, discrepancies between percentage depth-dose for Rhizophora spp and water, at all depths, are found to be within 2.6 and 2.4% respectively. At 12 MeV electron energies, measured percentage depth-doses in Rhizophora spp beyond 3.5 cm depth are found to be in significant discord with those for water. The absorbed dose in water measured in Rhizophora spp at d{sub max} for all three beams produces discrepancies of no more than 1.1% when compared with measurements made in water.

  12. Characterization and attenuation study on tannin-added Rhizophora spp. particleboard at high energy photon and electron

    Science.gov (United States)

    Yusof, Mohd Fahmi Mohd; Hamid, Puteri Nor Khatijah Abd; Tajuddin, Abd Aziz; Abdullah, Reduan; Hashim, Rokiah; Bauk, Sabar; Isa, Norriza Mohd; Isa, Muhammad Jamal Md

    2017-01-01

    The effective atomic number of tannin-added Rhizophora spp. particleboards was determined based on elemental composition using Energy Dispersive X-ray Analysis (EDXA). The value of mass attenuation coefficients were measured using 137Cs and 60Co gamma energies. The attenuation properties of PDD curves and beam profile of tannin-added Rhizophora spp. particleboards were investigated using Gafchromic EBT2 film at 6 MV photon and 6 MeV electrons and compared to the value in water and solid water phantoms. The results showed that tannin-added Rhizophora spp. particleboards having effective atomic number close to the value of water. The mass attenuation coefficients were near to the value of water with χ2 values of 0.018 and 0.357 to 137Cs and 60Co gamma energies respectively. The PDD of tannin-added Rhizophora spp. particleboards at 6 MV photons showed good agreement within 3.21 and 5.91% to that in solid water phantoms and water respectively. The PDD at 6 MeV electrons showed a good agreement within 3.32 and 3.12% to that in solid water phantoms and water respectively. The depth of R50 and R90 in tannin-added Rhizophora spp. also showed a good agreement to that in water and solid water pahtoms. Lower surface dose was observed in tannin-added Rhizophora spp. particleboards at electron beams in comparison to solid water phantoms and water.

  13. High-energy diffraction microscopy at the advanced photon source

    DEFF Research Database (Denmark)

    Lienert, U.; Li, S. F.; Hefferan, C. M.

    2011-01-01

    The status of the High Energy Diffraction Microscopy (HEDM) program at the 1-ID beam line of the Advanced Photon Source is reported. HEDM applies high energy synchrotron radiation for the grain and sub-grain scale structural and mechanical characterization of polycrystalline bulk materials in situ....... Complementary information is obtained by post mortem electron microscopy on the same sample volume previously investigated by HEDM....

  14. Photons as Ultra High Energy Cosmic Rays ?

    CERN Document Server

    Kalashev, O E; Semikoz, D V; Tkachev, Igor I

    2001-01-01

    We study spectra of the Ultra High Energy Cosmic Rays assuming primaries are protons and photons, and that their sources are extragalactic. We assume power low for the injection spectra and take into account the influence of cosmic microwave, infrared, optical and radio backgrounds as well as extragalactic magnetic fields on propagation of primaries. Our additional free parameters are the maximum energy of injected particles and the distance to the nearest source. We find a parameter range where the Greisen-Zatsepin-Kuzmin cut-off is avoided.

  15. Side-by-Side Comparison of DNA Damage Induced by Low Energy Electrons and High Energy Photons with Solid TpTpT Trinucleotide

    Science.gov (United States)

    Park, Yeunsoo; Peoples, Anita R.; Madugundu, Guru S.; Sanche, Léon; Wagner, J. Richard

    2013-01-01

    The genotoxic effects of high energy ionizing radiation have been largely attributed to the ionization of H2O leading to hydroxyl radicals (OH) and the ionization of DNA leading mostly to damage through base radical cations. However, the contribution of low energy electrons (LEEs; ≤ 10 eV), which involves sub-ionization events, has been considered to be less important than that of hydroxyl radicals and base radical cations. Here, we compare the ability of LEEs and high energy X-ray photons to induce DNA damage using dried thin films of TpTpT trinucleotide as a simple and representative model for DNA damage. The main radiation-induced damage of TpTpT as measured by HPLC-UV and LC-MS/MS analyses included thymine release (-Thy), strand breaks (pT, Tp, pTpT, TpTp and TpT), and the formation of base modifications (5,6-dihydrothymine (5,6-dhT), 5-hydroxymethyluracil (5-hmU) and 5-formyluracil (5-fU)). The global profile of products was very similar for both types of radiation indicating converging pathways of formation. The percent damage of thymine release, fragmentation and base modification was 20, 19 and 61 for high energy X-rays, respectively, compared to 35, 13 and 51 for LEEs (10 eV). Base release was significantly lower for X-rays. In both cases, phosphodiester bond cleavage gave mononucleotides (pT and Tp) and dinucleotides (pTpT and TpTp) containing a terminal phosphate as the major fragments. For base modifications, the ratio of reductive (5,6-dhT) to oxidative products (5-hmU plus 5-fU) was 0.9 for high energy X-rays compared to 1.7 for LEEs. These results indicate that LEEs give a similar profile of products compared to ionizing radiation. PMID:23909580

  16. Electron and Photon ID

    CERN Document Server

    Hryn'ova, Tetiana; The ATLAS collaboration

    2017-01-01

    The identification of prompt photons and the rejection of background coming mostly from photons from hadron decays relies on the high granularity of the ATLAS calorimeter. The electron identification used in ATLAS for run 2 is based on a likelihood discrimination to separate isolated electron candidates from candidates originating from photon conversions, hadron misidentification and heavy flavor decays. In addition, isolation variables are used as further handles to separate signal and background. Several methods are used to measure with data the efficiency of the photon identification requirements, to cover a broad energy spectrum. At low energy, photons from radiative Z decays are used. In the medium energy range, similarities between electrons and photon showers are exploited using Z->ee decays. At high energy, inclusive photon samples are used. The measurement of the efficiencies of the electron identification and isolation cuts are performed with the data using tag and probe techniques with large statis...

  17. High-energy electron diffraction and microscopy

    CERN Document Server

    Peng, L M; Whelan, M J

    2011-01-01

    This book provides a comprehensive introduction to high energy electron diffraction and elastic and inelastic scattering of high energy electrons, with particular emphasis on applications to modern electron microscopy. Starting from a survey of fundamental phenomena, the authors introduce the most important concepts underlying modern understanding of high energy electron diffraction. Dynamical diffraction in transmission (THEED) and reflection (RHEED) geometries is treated using ageneral matrix theory, where computer programs and worked examples are provided to illustrate the concepts and to f

  18. High Energy Electron Detectors on Sphinx

    Science.gov (United States)

    Thompson, J. R.; Porte, A.; Zucchini, F.; Calamy, H.; Auriel, G.; Coleman, P. L.; Bayol, F.; Lalle, B.; Krishnan, M.; Wilson, K.

    2008-11-01

    Z-pinch plasma radiation sources are used to dose test objects with K-shell (˜1-4keV) x-rays. The implosion physics can produce high energy electrons (> 50keV), which could distort interpretation of the soft x-ray effects. We describe the design and implementation of a diagnostic suite to characterize the electron environment of Al wire and Ar gas puff z-pinches on Sphinx. The design used ITS calculations to model detector response to both soft x-rays and electrons and help set upper bounds to the spurious electron flux. Strategies to discriminate between the known soft x-ray emission and the suspected electron flux will be discussed. H.Calamy et al, ``Use of microsecond current prepulse for dramatic improvements of wire array Z-pinch implosion,'' Phys Plasmas 15, 012701 (2008) J.A.Halbleib et al, ``ITS: the integrated TIGER series of electron/photon transport codes-Version 3.0,'' IEEE Trans on Nuclear Sci, 39, 1025 (1992)

  19. Response of monitoring instruments to high-energy photon radiation

    CERN Document Server

    Haridas, G; Pradhan, S D; Nayak, A R; Bhagwat, A M

    2000-01-01

    Response of commercially available monitoring instruments to high-energy photon radiation was studied under the stored beam condition of a few milliamperes in the storage ring of the Synchrotron Radiation Source, INDUS-I, at Centre for Advanced Technology (CAT), Indore. The storage ring has a circumference of 18.96 m, where electrons at 450 MeV are stored for a few hours, during which the emitted synchrotron radiation is exploited for scientific research and other applications. Radiation environment near storage ring has bremsstrahlung photons of various energies (maximum 450 MeV). A study has indicated underestimation of dose by conventional radiation monitoring instruments by a factor of 2-4. Response after transmission of photons through massive shield was also studied, which indicated spectral degradation and good response by the survey meters.

  20. ATLAS event containing two high energy photons

    CERN Multimedia

    ATLAS

    2011-01-01

    An event where two energetic photons ("gammas") are produced in a proton-proton collision in ATLAS. Many events of this type are produced by well-understood Standard Model processes ("backgrounds") which do not involve Higgs particles. A small excess of events of this type with similar masses could indicate evidence for Higgs particle production, but any specific event is most likely to be from the background.

  1. Direct photon production in high-energy nuclear collisions

    NARCIS (Netherlands)

    Peitzmann, T.

    2016-01-01

    Direct photons have always been considered a promising probe for the very early phases of high-energy nuclear collisions. Prompt photons reveal information about the initial state and its possible modifications in nuclei. In this context they should be one of the best probes for effects of gluon

  2. Progress toward high energy electron cooling

    Energy Technology Data Exchange (ETDEWEB)

    Sergei Nagaitsev

    2001-07-20

    All electron cooling systems in operation to date can be classified as low energy systems. The electron beam kinetic energy in such a system is limited to about 0.6-1 MeV by the use of a conventional commercial Cockcroft-Walton high-voltage power supply. This, in turn, bounds the maximum ion kinetic energy, accessible for cooling with today's standard technology, to about 2 GeV/nucleon (about a factor of 2-3 times higher than the electron systems in operation today). Electron cooling systems with kinetic energies above 1 MeV could provide economically justifiable improvements in the performance of many existing and proposed accelerator complexes, such as RHIC, Tevatron and HERA. This paper reviews the status of the development of the technology needed for high energy electron cooling.

  3. GZK Photons as Ultra High Energy Cosmic Rays

    CERN Document Server

    Gelmini, G; Semikoz, D V; Gelmini, Graciela; Kalashev, Oleg; Semikoz, Dmitry V.

    2005-01-01

    We calculate the flux of "GZK-photons", namely the flux of Ultra High Energy Cosmic Rays (UHECR) consisting of photons produced by extragalactic protons through the resonant photoproduction of pions, the so called Greisen-Zatsepin-Kuzmin (GZK) effect. We show that if the UHECR are mostly protons, depending on the UHECR spectrum, the slope of the proton flux at the source, distribution of sources and intervening backgrounds, between $10^{-4}$ and $10^{-2}$ of the UHECR above $10^{19}$ eV and between $10^{-5}$ and 0.6 of the UHECR above $10^{20}$ eV are photons (the range being much higher for the AGASA than for the HiRes spectrum). Detection of these photons would open the way for UHECR gamma-ray astronomy. Detection of a larger photon flux would imply the emission of photons at the source or new physics. In fact, we find that at energiesclose to $10^{20}$ eV the maximum expected GZK photon fraction is comparable to (for the AGASA spectrum) or much smaller than (for the HiRes spectrum) the minimum photon ratio...

  4. High energy high intensity coherent photon beam for the SSC

    Energy Technology Data Exchange (ETDEWEB)

    Tannenbaum, M.J.

    1984-01-01

    What is proposed for the 20 TeV protons hitting a fixed target is to make a tertiary electron beam similar to that which is the basis of the tagged photon beam at Fermilab. Briefly, a zero degree neutral beam is formed by sweeping out the primary proton beam and any secondary charged particles. Then the photons, from the decay of ..pi../sup 0/ in the neutral beam, are converted to e/sup +/e/sup -/ pairs in a lead converter and a high quality electron beam is formed. This beam is brought to the target area where it is converted to a photon beam by Bremsstrahlung in a radiator.

  5. Soft-photon emission effects and radiative corrections for electromagnetic processes at very high energies

    Science.gov (United States)

    Gould, R. J.

    1979-01-01

    Higher-order electromagnetic processes involving particles at ultrahigh energies are discussed, with particular attention given to Compton scattering with the emission of an additional photon (double Compton scattering). Double Compton scattering may have significance in the interaction of a high-energy electron with the cosmic blackbody photon gas. At high energies the cross section for double Compton scattering is large, though this effect is largely canceled by the effects of radiative corrections to ordinary Compton scattering. A similar cancellation takes place for radiative pair production and the associated radiative corrections to the radiationless process. This cancellation is related to the well-known cancellation of the infrared divergence in electrodynamics.

  6. Regularity of high energy photon events from gamma ray bursts

    Science.gov (United States)

    Xu, Haowei; Ma, Bo-Qiang

    2018-01-01

    The effect of Quantum Gravity (QG) may bring a tiny light speed variation as v(E)=c(1‑E/ELV), where E is the photon energy and ELV is a Lorentz violation scale. A remarkable regularity was suggested in previous studies to look for the light speed variation from high energy photon events of Gamma Ray Bursts (GRBs). We provide a general analysis on the data of 25 bright GRBs observed by the Fermi Gamma-ray Space Telescope (FGST). Such method allows a completed scan over all possibilities in a more clean and impartial way without any bias compared to previous intuitive analysis. The results show that with the increase in the intrinsic energies of photons, such regularity truly emerges and gradually becomes significant. For photons with intrinsic energies higher than 40 GeV, the regularity exists at a significance of 3–5 σ with ELV=3.6× 1017 GeV determined by the GRB data.

  7. Local enhancement of radiation dose by using high atomic number materials with high energy photon beam

    Science.gov (United States)

    Alkhatib, Ahmad Khaled

    The goal of treatment planning in radiation therapy is to maximize the absorbed dose in abnormal cells and minimize the dose in normal cells. It is long established that the probability of pair production interactions (converting photon to electron and positron see chapter II) increases with the increase of the photon energy above a 1.02 MV threshold and with the square of the atomic number of the medium. In this work I tried to locally enhance the absorbed dose by using both a high energy photon beam and high Z material (Gold foils), to observe the effect of the secondary electrons that are produced in the high z material (gold) with high energy photons (end point energy 25MV). To observe the range of these secondary electrons, I changed the gap between two gold foils. I studied also the effect of varying the thickness of both gold foils. To verify the dependence of the atomic number (Z) I repeated the measurements with two Aluminum foils, and to observe the effect of The Higher photon energy I used a range of photon beams with end point energies 6, 10, 15, 18 and 25 MV. I used Monte Carlo code to confirm the result. The calculated dose enhancements from the simulation were in general 5% higher the measured values.

  8. Fundamentals of high energy electron beam generation

    Science.gov (United States)

    Turman, B. N.; Mazarakis, M. G.; Neau, E. L.

    High energy electron beam accelerator technology has been developed over the past three decades in response to military and energy-related requirements for weapons simulators, directed-energy weapons, and inertially-confined fusion. These applications required high instantaneous power, large beam energy, high accelerated particle energy, and high current. These accelerators are generally referred to as 'pulsed power' devices, and are typified by accelerating potential of millions of volts (MV), beam current in thousands of amperes (KA), pulse duration of tens to hundreds of nanoseconds, kilojoules of beam energy, and instantaneous power of gigawatts to teffawatts (10(exp 9) to 10(exp 12) watts). Much of the early development work was directed toward single pulse machines, but recent work has extended these pulsed power devices to continuously repetitive applications. These relativistic beams penetrate deeply into materials, with stopping range on the order of a centimeter. Such high instantaneous power deposited in depth offers possibilities for new material fabrication and processing capabilities that can only now be explored. Fundamental techniques of pulse compression, high voltage requirements, beam generation and transport under space-charge-dominated conditions will be discussed in this paper.

  9. High energy electron-positron physics

    CERN Document Server

    Ali, Ahmed

    1988-01-01

    With the termination of the physics program at PETRA, and with the start of TRISTAN and the SLC and later LEP, an era of e+e- physics has come to an end and a new one begins. The field is changing from a field of few specialists, to becoming one of the mainstream efforts of the high energy community. It seems appropriate at this moment to summarize what has been learned over the past years, in a way most useful to any high energy physicists, in particular to newcomers in the e+e- field. This is the purpose of the book. This book should be used as a reference for future workers in the field of

  10. Portable radiation detection system for pulsed high energy photon sources

    Energy Technology Data Exchange (ETDEWEB)

    Harker, Y.D.; Lawrence, R.S.; Yoon, W.Y. [Idaho National Engineering Lab, Idaho Falls, ID (United States)] [and others

    1994-12-31

    Portable, battery-operated, radiation detection systems for measuring the intensity and energy characteristics of intense, pulsed photon sources (either high energy X-ray or gamma) have been developed at the Idaho National Engineering Laboratory. These field-deployable, suitcase-sized detection units are designed to measure and record the characteristics of a single radiation burst or multiple bursts from a pulsed ionizing radiation source. The recorded information can then be analyzed on a simple laptop computer at a location remote from the detection system and completely independent of the ongoing data acquisition process. Two detection unit designs are described. The first, called the MARK-1, has eight bismuth germanate (BGO) radiation detectors. Four of which are unshielded and have different thicknesses (diameters). The remaining four are the same size as the largest unshielded detector but have different thicknesses of lead shielding surrounding each detector. The second unit design, called the MARK-1 A, utilizes the same detection methodology as the MARK-1 but has ten BGO detectors instead of eight and utilizes a different method of amplifying detector signals enabling reduced overall size and weight of the detection unit. Both the detection system designs have sensitivity ranges from 3 x 10{sup {minus}9} cGy to 9 x 10{sup {minus}5} cGy per radiation burst. Experimental detection results will be presented and discussed along the systems` potential for commercial applications.

  11. ELEC-2005: Electronics in High Energy Physics

    CERN Multimedia

    Monique Duval

    2004-01-01

    ELEC-2005 is a new course series on modern electronics, given by CERN physicists and engineers in the format of the successful ELEC-2002 course series, and within the framework of the 2005 Technical Training Programme. This comprehensive course series is designed for people who are not electronics specialists, for example physicists, engineers and technicians working at or visiting the laboratory, who use or will use electronics in their present or future activities, in particular in the context of the LHC accelerator and experiments. ELEC-2005 will composed of four Terms throughout the year: Winter Term: Introduction to electronics in HEP (January-February, 6 lectures) Spring Term: Integrated circuits and VLSI technology for physics (March, 6 lectures) Summer Term: System electronics for physics: Issues (May, 7 lectures) Winter Term: Electronics applications in HEP experiments (November-December, 10 lectures) Lectures within each Term will take place on Tuesdays and Thursdays, from 10:00 to 12:30. The...

  12. Electron clouds in high energy hadron accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Petrov, Fedor

    2013-08-29

    The formation of electron clouds in accelerators operating with positrons and positively charge ions is a well-known problem. Depending on the parameters of the beam the electron cloud manifests itself differently. In this thesis the electron cloud phenomenon is studied for the CERN Super Proton Synchrotron (SPS) and Large Hadron Collider (LHC) conditions, and for the heavy-ion synchrotron SIS-100 as a part of the FAIR complex in Darmstadt, Germany. Under the FAIR conditions the extensive use of slow extraction will be made. After the acceleration the beam will be debunched and continuously extracted to the experimental area. During this process, residual gas electrons can accumulate in the electric field of the beam. If this accumulation is not prevented, then at some point the beam can become unstable. Under the SPS and LHC conditions the beam is always bunched. The accumulation of electron cloud happens due to secondary electron emission. At the time when this thesis was being written the electron cloud was known to limit the maximum intensity of the two machines. During the operation with 25 ns bunch spacing, the electron cloud was causing significant beam quality deterioration. At moderate intensities below the instability threshold the electron cloud was responsible for the bunch energy loss. In the framework of this thesis it was found that the instability thresholds of the coasting beams with similar space charge tune shifts, emittances and energies are identical. First of their kind simulations of the effect of Coulomb collisions on electron cloud density in coasting beams were performed. It was found that for any hadron coasting beam one can choose vacuum conditions that will limit the accumulation of the electron cloud below the instability threshold. We call such conditions the ''good'' vacuum regime. In application to SIS-100 the design pressure 10{sup -12} mbar corresponds to the good vacuum regime. The transition to the bad vacuum

  13. Conversion of zero point energy into high-energy photons

    Energy Technology Data Exchange (ETDEWEB)

    Ivlev, B. I. [Universidad Autonoma de San Luis Potosi, Instituto de Fisica, Av. Manuel Nava No. 6, Zona Universitaria, 78290 San Luis Potosi, SLP (Mexico)

    2016-11-01

    An unusual phenomenon, observed in experiments is studied. X-ray laser bursts of keV energy are emitted from a metal where long-living states, resulting in population inversion, are totally unexpected. Anomalous electron-photon states are revealed to be formed inside the metal. These states are associated with narrow, 10{sup -11} cm, potential well created by the local reduction of zero point electromagnetic energy. In contrast to analogous van der Waals potential well, leading to attraction of two hydrogen atoms, the depth of the anomalous well is on the order of 1 MeV. The states in that well are long-living which results in population inversion and subsequent laser generation observed. The X-ray emission, occurring in transitions to lower levels, is due to the conversion of zero point electromagnetic energy. (Author)

  14. Influence of high energy electrons on ECRH in LHD

    Directory of Open Access Journals (Sweden)

    Ogasawara S.

    2012-09-01

    Full Text Available The central bulk electron temperature of more than 20 keV is achieved in LHD as a result of increasing the injection power and the lowering the electron density near 2 × 1018 m−3. Such collision-less regime is important from the aspect of the neoclassical transport and also the potential structure formation. The presences of appreciable amount of high energy electrons are indicated from hard X-ray PHA, and the discrepancy between the stored energy and kinetic energy estimated from Thomson scattering. ECE spectrum are also sensitive to the presence of high energy electrons and discussed by solving the radiation transfer equation. The ECRH power absorption to the bulk and the high energy electrons are dramatically affected by the acceleration and the confinement of high energy electrons. The heating mechanisms and the acceleration process of high energy electrons are discussed by comparing the experimental results and the ray tracing calculation under assumed various density and mean energy of high energy electrons.

  15. Radiation-hard silicon photonics for high energy physics and beyond

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    Silicon photonics (SiPh) is currently being investigated as a promising technology for future radiation hard optical links. The possibility of integrating SiPh devices with electronics and/or silicon particle sensors as well as an expected very high resistance against radiation damage make this technology particularly interesting for potential use close to the interaction points in future in high energy physics experiments and other radiation-sensitive applications. The presentation will summarize the outcomes of the research on radiation hard SiPh conducted within the ICE-DIP projected.

  16. Spectral shape variation of interstellar electrons at high energies

    Science.gov (United States)

    Tan, L. C.

    1985-01-01

    The high energy electron spectrum analysis has shown that the electron intensity inside the H2 cloud region, or in a spiral arm, should be much lower than that outside it and the observed electron energy spectrum should flatten again at about 1 TeV. In the framework of the leady box model the recently established rigidity dependence of the escape pathlength of cosmic rays would predict a high energy electron spectrum which is flatter than the observed one. This divergence is explained by assuming that the leaky box model can only apply to cosmic ray heavy nuclei, and light nuclei and electrons in cosmic rays may have different behaviors in the interstellar propagation. Therefore, the measured data on high energy electrons should be analyzed based on the proposed nonuniform galactic disk (NUGD) mode.

  17. A multichannel single-photon sensitive detector for high-energy physics: the megapixel EBCCD

    CERN Document Server

    Benussi, L; Frekers, D; Frenkel, A; Giannini, G; Golovkin, S V; Kozarenko, E N; Kreslo, I E; Liberti, B; Martellotti, G; Medvedkov, A M; Mondardini, M R; Penso, G; Polizzi, A; Santacesaria, R; Santini, G; Spinetti, M; Vilain, P; Votano, L; Wilquet, G; Winter, Klaus

    2000-01-01

    We present a study of the characteristics of a hybrid image intensifier tube based on a thinned backside Electron Bombarded CCD (EBCCD) with better performance in spatial resolution, single photoelectron detection and gain stability than the conventional intensified systems based on a Micro Channel Plate followed by a CCD. Single photon detection sensitivity has been studied and a procedure to correct the gain non-uniformity of the EBCCD has been developed. The EBCCD, operating at 14 kV, has an average gain of approx 3000 electrons/photoelectron and a noise of the order of 100 electron/pixel. These characteristics make the EBCCD a very attractive device for many applications in high-energy physics, astrophysics and biomedicine. A possible application in a neutrino oscillation experiment is presented.

  18. Trajectories of high energy electrons in a plasma focus

    Science.gov (United States)

    Harries, W. L.; Lee, J. H.; Mcfarland, D. R.

    1978-01-01

    Measurements are made of high-energy electron trajectories in a plasma focus as functions of position, time, energy, and angle of emission. The spatial resolution of the X-ray emission shows that low-energy X-rays are emitted from the anode surface. It is also suggested that the highest energy X-rays originate from a small region on the axis. The so-called shadow technique shows that the electron beam is perpendicular to the anode surface. Polar diagrams of medium and high-energy X-rays agree with the bremsstrahlung emission from a relativistic electron beam, the current of which is several 100 A.

  19. ATLAS proton-proton event containing two high energy photons

    CERN Multimedia

    ATLAS Collaboration

    2011-01-01

    An event where two energetic photons ("gammas") are produced in a proton-proton collision in ATLAS. Many events of this type are produced by well-understood Standard Model processes ("backgrounds") which do not involve Higgs particles. A small excess of events of this type with similar masses could indicate evidence for Higgs particle production, but any specific event is most likely to be from the background. The photons are indicated, in the different projections and views, by the clusters of energy shown in yellow.

  20. High energy photon and particle luminosity from active nuclei

    Science.gov (United States)

    Eilek, J. A.; Caroff, L. J.; Noerdlinger, P. D.; Dove, M. E.

    1986-01-01

    This paper describes a numerical calculation which follows the evolution of an initial photon and particle spectrum in an expanding, relativistic wind or jet, describes in particular the quasi-equilibrium distribution found for initial optical depths above 100 or so, and points out that this calculation may be relevant for the situation in luminous, compact nuclear sources.

  1. Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons

    Energy Technology Data Exchange (ETDEWEB)

    Ballester, Facundo; Granero, Domingo; Perez-Calatayud, Jose; Melhus, Christopher S.; Rivard, Mark J. [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, C/Dr. Moliner 50, E-46100 Burjassot (Spain) and IFIC, CSIC-University of Valencia, C/Dr. Moliner 50, E-46100 Burjassot (Spain); Department of Radiation Physics, ERESA, Hospital General Universitario, Avenida Tres Cruces, 2, E-46014 Valencia (Spain); Department of Radiation Oncology, La Fe University Hospital, Avenida Campanar 21, E-46009 Valencia (Spain); Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States)

    2009-09-15

    Purpose: The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides ({sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Methods: Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source {beta}{sup -}, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the {sup 192}Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Results: Electronic equilibrium within 1% is reached for {sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for {sup 60}Co and {sup 192}Ir, respectively. Electron emissions become important (i.e., >0.5%) within 3.3 mm of {sup 60}Co and 1.7 mm of {sup 192}Ir sources, yet are negligible over all distances for {sup 137}Cs and {sup 169}Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Conclusions: Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

  2. A Study of the use of a Crystal as a `Quarter-Wave Plate' to Produce High Energy Circularly Polarized Photons

    CERN Multimedia

    Kononets, I

    2002-01-01

    %NA59 %title\\\\ \\\\We present a proposal to study the use of a crystal as a `quarter-wave plate' to produce high energy circularly polarized photons, starting from unpolarized electrons. The intention is to generate linearly polarized photons by letting electrons pass a crystalline target, where they interact coherently with the lattice nuclei. The photon polarization is subsequently turned into circular polarization after passing another crystal, which acts as a `quarter-wave plate'.

  3. Development of an efficient scanning and purging magnet system for IMRT with narrow high energy photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Andreassen, Bjoern, E-mail: bjorn.andreassen@gmail.co [Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, P.O. Box 260, SE-171 76 Stockholm (Sweden); Svensson, Roger; Holmberg, Rickard [Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, P.O. Box 260, SE-171 76 Stockholm (Sweden); Danared, Hakan [Manne Siegbahn Laboratory, Stockholm University, Frescativaegen 26, SE-114 18 Stockholm (Sweden); Brahme, Anders [Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, P.O. Box 260, SE-171 76 Stockholm (Sweden)

    2009-12-21

    Due to the clinical advantages of Intensity Modulated Radiation Therapy (IMRT) high flexibility and accuracy in intensity modulated dose delivery is desirable to really maximize treatment outcome. Although it is possible to deliver IMRT by using broad beams in combination with dynamic multileaf collimation the process is rather time consuming and inefficient. By using narrow scanned high energy photon beams the treatment outcome can be improved, the treatment time reduced and accurate 3D in vivo dose delivery monitoring is possible by PET-CT based dose delivery imaging of photo nuclear reactions in human tissues. Narrow photon beams can be produced by directing a low emittance high energy electron beam on a thin target, and then cleaning the therapeutic photon beam from transmitted high energy electrons, and photon generated charged leptons, with a dedicated purging magnet placed directly downstream of the target. To have an effective scanning and purging magnet system the purging magnet should be placed immediately after the bremsstrahlung target to deflect the transmitted electrons to an efficient electron stopper. In the static electron stopper the electrons should be safely collected independent of the desired direction of the therapeutic scanned photon beam. The SID (Source to Isocenter Distance) should preferably be short while retaining the ability to scan over a large area on the patient and consequently there are severe requirements both on the strength and the geometry of the scanning and purging magnets. In the present study an efficient magnet configuration with a purging and scanning magnet assembly is developed for electron energies in the 50-75 MeV range and a SID of 75 cm. For a bremsstrahlung target of 3 mm Be these electron energies produce a photon beam of 25-17 mm FWHM (Full Width Half Maximum) at a SID of 75 cm. The magnet system was examined both in terms of the efficiency in scanning the narrow bremsstrahlung beam and the deflection of

  4. Short-pulse, high-energy radiation generation from laser-wakefield accelerated electron beams

    Science.gov (United States)

    Schumaker, Will

    2013-10-01

    Recent experimental results of laser wakefield acceleration (LWFA) of ~GeV electrons driven by the 200TW HERCULES and the 400TW ASTRA-GEMINI laser systems and their subsequent generation of photons, positrons, and neutrons are presented. In LWFA, high-intensity (I >1019 W /cm2), ultra-short (τL counter-propagating, ultra-high intensity (I >1021 W /cm2) laser pulse to undergo inverse Compton scattering and emit a high-peak brightness beam of high-energy photons. Preliminary results and experimental sensitivities of the electron-laser beam overlap are presented. The high-energy photon beams can be spectrally resolved using a forward Compton scattering spectrometer. Moreover, the photon flux can be characterized by a pixelated scintillator array and by nuclear activation and (γ,n) neutron measurements from the photons interacting with a secondary solid target. Monte-Carlo simulations were performed using FLUKA to support the yield estimates. This research was supported by DOE/NSF-PHY 0810979, NSF CAREER 1054164, DARPA AXiS N66001-11-1-4208, SF/DNDO F021166, and the Leverhulme Trust ECF-2011-383.

  5. Technical Training: ELEC-2005: Electronics in High Energy Physics

    CERN Multimedia

    Monique Duval

    2005-01-01

    CERN Technical Training 2005: Learning for the LHC! ELEC-2005: Electronics in High Energy Physics - Spring Term ELEC-2005 is a new course series on modern electronics, given by CERN physicists and engineers within the framework of the 2005 Technical Training Programme, in an extended format of the successful ELEC-2002 course series. This comprehensive course series is designed for people who are not electronics specialists, for example physicists, engineers and technicians working at or visiting the laboratory, who use or will use electronics in their present or future activities, in particular in the context of the LHC accelerator and experiments. ELEC-2005 is composed of four Terms: the Winter Term, Introduction to electronics in HEP, already took place; the next three Terms will run throughout the year: Spring Term: Integrated circuits and VLSI technology for physics (March, 6 lectures) - now open for registration Summer Term: System electronics for physics: Issues (May, 7 lectures) Autumn Term: Ele...

  6. PROGRESS OF HIGH-ENERGY ELECTRON COOLING FOR RHIC.

    Energy Technology Data Exchange (ETDEWEB)

    FEDOTOV,A.V.

    2007-09-10

    The fundamental questions about QCD which can be directly answered at Relativistic Heavy Ion Collider (RHIC) call for large integrated luminosities. The major goal of RHIC-I1 upgrade is to achieve a 10 fold increase in luminosity of Au ions at the top energy of 100 GeV/nucleon. Such a boost in luminosity for RHIC-II is achievable with implementation of high-energy electron cooling. The design of the higher-energy cooler for RHIC-II recently adopted a non-magnetized approach which requires a low temperature electron beam. Such electron beams will be produced with a superconducting Energy Recovery Linac (ERL). Detailed simulations of the electron cooling process and numerical simulations of the electron beam transport including the cooling section were performed. An intensive R&D of various elements of the design is presently underway. Here, we summarize progress in these electron cooling efforts.

  7. Production of high energy electrons by irradiation of fs-pulse laser on copper film

    Energy Technology Data Exchange (ETDEWEB)

    Oishi, Yuji; Nayuki, Takuya; Fujii, Takashi; Nemoto, Koshichi [Central Research Inst. of Electric Power Industry, Komae, Tokyo (Japan); Kayoiji, Tsutomu [Tokyo Inst. of Technology, Interdisciplinary Graduate School of Science and Engineering, Yokohama, Kanagawa (Japan); Okano, Yasuaki; Hironaka, Yoichiro; Nakamura, Kazutaka G.; Kondo, Ken-ichi [Tokyo Inst. of Technology, Materials and Structures Laboratory, Yokohama, Kanagawa (Japan)

    2002-07-01

    Fast electrons with energy corresponding to the ponderomotive potential were produced by laser irradiation of 43-fs, 2.7 X 10{sup 18} W/cm{sup 2} on a 30 {mu}m thick copper target. The energy spectra of the electrons were directly measured using a magnetic spectrometer with an imaging plate. The typical temperature was 350 keV for irradiation at 15deg incidence angle. The energy spectra of high-energy photons, which were expected to be produced from the electrons, were also calculated. (author)

  8. Parity nonconservation in polarized electron scattering at high energies

    Energy Technology Data Exchange (ETDEWEB)

    Prescott, C.Y.

    1979-10-01

    Recent observations of parity violation in inelastic scattering of electrons at high energy is discussed with reference to the process e(polarized) + D(unpolarized) ..-->.. e + X. The kinetics of this process, the idealized case of scattering from free quark targets, experimental techniques and results, and relations to atomic physics of parity violation in bismuth and thallium atoms with a model independent analysis. 17 references. (JFP)

  9. Preliminary investigations on high energy electron beam tomography

    Energy Technology Data Exchange (ETDEWEB)

    Baertling, Yves; Hoppe, Dietrich; Hampel, Uwe

    2010-12-15

    In computed tomography (CT) cross-sectional images of the attenuation distribution within a slice are created by scanning radiographic projections of an object with a rotating X-ray source detector compound and subsequent reconstruction of the images from these projection data on a computer. CT can be made very fast by employing a scanned electron beam instead of a mechanically moving X-ray source. Now this principle was extended towards high-energy electron beam tomography with an electrostatic accelerator. Therefore a dedicated experimental campaign was planned and carried out at the Budker Institute of Nuclear Physics (BINP), Novosibirsk. There we investigated the capabilities of BINP's accelerators as an electron beam generating and scanning unit of a potential high-energy electron beam tomography device. The setup based on a 1 MeV ELV-6 (BINP) electron accelerator and a single detector. Besides tomographic measurements with different phantoms, further experiments were carried out concerning the focal spot size and repeat accuracy of the electron beam as well as the detector's response time and signal to noise ratio. (orig.)

  10. LIMITS TO THE FRACTION OF HIGH-ENERGY PHOTON EMITTING GAMMA-RAY BURSTS

    Energy Technology Data Exchange (ETDEWEB)

    Akerlof, Carl W.; Zheng, WeiKang, E-mail: akerlof@umich.edu [Department of Physics, University of Michigan, 450 Church Street, Ann Arbor, MI 48109-1040 (United States)

    2013-02-20

    After almost four years of operation, the two instruments on board the Fermi Gamma-ray Space Telescope have shown that the number of gamma-ray bursts (GRBs) with high-energy photon emission above 100 MeV cannot exceed roughly 9% of the total number of all such events, at least at the present detection limits. In a recent paper, we found that GRBs with photons detected in the Large Area Telescope have a surprisingly broad distribution with respect to the observed event photon number. Extrapolation of our empirical fit to numbers of photons below our previous detection limit suggests that the overall rate of such low flux events could be estimated by standard image co-adding techniques. In this case, we have taken advantage of the excellent angular resolution of the Swift mission to provide accurate reference points for 79 GRB events which have eluded any previous correlations with high-energy photons. We find a small but significant signal in the co-added field. Guided by the extrapolated power-law fit previously obtained for the number distribution of GRBs with higher fluxes, the data suggest that only a small fraction of GRBs are sources of high-energy photons.

  11. Development of twin Ge detector for high energy photon measurement and its performance

    Energy Technology Data Exchange (ETDEWEB)

    Shigetome, Yoshiaki; Harada, Hideo [Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan). Tokai Works

    1998-03-01

    Prototype twin HPGe detector composed of two large HPGe crystals was developed to obtain better detection efficiency ({epsilon}) and P/T ratio, which was required for high energy photon spectroscopy. In this work, the performances of the twin HPGe detector were evaluated by computer simulation employing EGS4 code. (author)

  12. Photon and dilepton production in high-energy heavy-ion collisions

    Indian Academy of Sciences (India)

    2015-05-07

    May 7, 2015 ... The recent results on direct photons and dileptons in high-energy heavy-ion collisions, obtained particularly at Relativistic Heavy Ion Collider (RHIC) and Large Hadron Collider (LHC) are reviewed. The results are new not only in terms of the probes, but also in terms of the precision. We shall discuss the ...

  13. LHC collision event at CMS showing two high energy photons (CMS Higgs search)

    CERN Multimedia

    CMS Collaboration

    2011-01-01

    11sec animation of a Higgs->GammaGamma candidate in CMS. Real CMS proton-proton collision events in which two high energy photons (dashed orange lines and towers) are observed. The event shows characteristics expected from the decay of a Higgs boson but is also consistent with background Standard Model physics processes.

  14. Narrow beam dosimetry for high-energy hadrons and electrons

    CERN Document Server

    Pelliccioni, M; Ulrici, Luisa

    2001-01-01

    Organ doses and effective dose were calculated with the latest version of the Monte Carlo transport code FLUKA in the case of an anthropomorphic mathematical model exposed to monoenergetic narrow beams of protons, pions and electrons in the energy range 10°— 400 GeV. The target organs considered were right eye, thyroid, thymus, lung and breast. Simple scaling laws to the calculated values are given. The present data and formula should prove useful for dosimetric estimations in case of accidental exposures to high-energy beams.

  15. Stringy Space-Time Foam and High-Energy Cosmic Photons

    CERN Document Server

    Mavromatos, Nick E

    2011-01-01

    In this review, I discuss briefly stringent tests of Lorentz-violating quantum space-time foam models inspired from String/Brane theories, provided by studies of high energy Photons from intense celestial sources, such as Active Galactic Nuclei or Gamma Ray Bursts. The theoretical models predict modifications to the radiation dispersion relations, which are quadratically suppressed by the string mass scale, and time delays in the arrival times of photons (assumed to be emitted more or less simultaneously from the source), which are proportional to the photon energy, so that the more energetic photons arrive later. Although the astrophysics at the source of these energetic photons is still not understood, and such non simultaneous arrivals, that have been observed recently, might well be due to non simultaneous emission as a result of conventional physics effects, nevertheless, rather surprisingly, the observed time delays can also fit excellently the stringy space-time foam scenarios, provided the space-time ...

  16. Do high-energy neutrinos travel faster than photons in a discrete space-time?

    Energy Technology Data Exchange (ETDEWEB)

    Xue Shesheng, E-mail: xue@icra.it [ICRANeT, Piazzale della Repubblica, 10-65122, Pescara, Physics Department, University of Rome ' ' La Sapienza' ' , Rome (Italy)

    2011-12-06

    The recent OPERA measurement of high-energy neutrino velocity, once independently verified, implies new physics in the neutrino sector. We revisit the theoretical inconsistency of the fundamental high-energy cutoff attributing to quantum gravity with the parity-violating gauge symmetry of local quantum field theory describing neutrinos. This inconsistency suggests high-dimension operators of neutrino interactions. Based on these studies, we try to view the OPERA result, high-energy neutrino oscillations and indicate to observe the restoration of parity conservation by measuring the asymmetry of high-energy neutrinos colliding with left- and right-handed polarized electrons.

  17. Faint High-energy Gamma-Ray Photon Emission of GRB 081006A from Fermi Observations

    Science.gov (United States)

    Zheng, WeiKang; Akerlof, Carl W.; Pandey, Shashi B.; McKay, Timothy A.; Zhang, BinBin; Zhang, Bing

    2012-01-01

    Since the launch of the Fermi Gamma-ray Space Telescope on 2008 June 11, the Large Area Telescope (LAT) instrument has firmly detected more than 20 gamma-ray bursts (GRBs) with high-energy photon emission above 100 MeV. Using the matched filter technique, three more GRBs have also shown evidence of correlation with high-energy photon emission as demonstrated by Akerlof et al. In this paper, we present another GRB, GRB 081006A, unambiguously detected by the matched filter technique. This event is associated with more than 13 high-energy photons above 100 MeV. The likelihood analysis code provided by the Fermi Science Support Center generated an independent verification of this detection using a comparison of the test statistics value with similar calculations for random LAT data fields. We have performed detailed temporal and spectral analysis of photons from 8 keV up to 0.8 GeV from the Gamma-ray Burst Monitor and the LAT. The properties of GRB 081006A can be compared to those of the other two long-duration GRBs detected at similar significance, GRB 080825C and GRB 090217A. We find that GRB 081006A is more similar to GRB 080825C with comparable appearances of late high-energy photon emission. As demonstrated previously, there appears to be a surprising dearth of faint LAT GRBs, with only one additional GRB identified in a sample of 74. In this unique period when both Swift and Fermi are operational, there is some urgency to explore this aspect of GRBs as fully as possible.

  18. FAINT HIGH-ENERGY GAMMA-RAY PHOTON EMISSION OF GRB 081006A FROM FERMI OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Zheng Weikang; Akerlof, Carl W.; Pandey, Shashi B.; McKay, Timothy A. [Department of Physics, University of Michigan, 450 Church Street, Ann Arbor, MI 48109 (United States); Zhang Binbin; Zhang Bing, E-mail: zwk@umich.edu [Department of Physics and Astronomy, University of Nevada, Las Vegas, NV 89154 (United States)

    2012-01-20

    Since the launch of the Fermi Gamma-ray Space Telescope on 2008 June 11, the Large Area Telescope (LAT) instrument has firmly detected more than 20 gamma-ray bursts (GRBs) with high-energy photon emission above 100 MeV. Using the matched filter technique, three more GRBs have also shown evidence of correlation with high-energy photon emission as demonstrated by Akerlof et al. In this paper, we present another GRB, GRB 081006A, unambiguously detected by the matched filter technique. This event is associated with more than 13 high-energy photons above 100 MeV. The likelihood analysis code provided by the Fermi Science Support Center generated an independent verification of this detection using a comparison of the test statistics value with similar calculations for random LAT data fields. We have performed detailed temporal and spectral analysis of photons from 8 keV up to 0.8 GeV from the Gamma-ray Burst Monitor and the LAT. The properties of GRB 081006A can be compared to those of the other two long-duration GRBs detected at similar significance, GRB 080825C and GRB 090217A. We find that GRB 081006A is more similar to GRB 080825C with comparable appearances of late high-energy photon emission. As demonstrated previously, there appears to be a surprising dearth of faint LAT GRBs, with only one additional GRB identified in a sample of 74. In this unique period when both Swift and Fermi are operational, there is some urgency to explore this aspect of GRBs as fully as possible.

  19. Circular dichroism in free-free transitions of high energy electron-atom scattering

    CERN Document Server

    Cionga, Aurelia; Zloh, Gabriela; 10.1103/PhysRevA.62.063406

    2013-01-01

    We consider high energy electron scattering by hydrogen atoms in the presence of a laser field of moderate power and higher frequencies. If the field is a superposition of a linearly and a circularly polarized laser beam in a particular configuration, then we can show that circular dichroism in two photon transitions can be observed not only for the differential but also for the integrated cross sections, provided the laser-dressing of the atomic target is treated in second order perturbation theory and the coupling between hydrogenic bound and continuum states is involved.

  20. Calculation of the characteristics of clinical high-energy photon beams with EGS5-MPI

    Science.gov (United States)

    Shimizu, M.; Morishita, Y.; Kato, M.; Kurosawa, T.; Tanaka, T.; Takata, N.; Saito, N.

    2014-03-01

    A graphite calorimeter has been developed as a Japanese primary standard of absorbed dose to water in the high-energy photon beams from a clinical linac. To obtain conversion factors for the graphite calorimeter, the beam characteristics of the high-energy photon beams from the clinical linac at National Metrology Institute of Japan were calculated with the EGS5 Monte Carlo simulation code. To run the EGS5 code on High Performance Computing machines that have more than 1000 CPU cores, we developed the EGS5 parallelisation package "EGS5-MPI" by implementing a message-passing interface. We calculated the photon energy spectra, which are in good agreement with those previously calculated by D. Sheikh-Bagheri and D. W. O. Rogers (Med. Phys. 29 3). We also estimated the percentage-depth-dose distributions of photon beams from the linac using the calculated photon energy spectra. These calculated percentage-depth-dose distributions were compared with our measured distributions and were found they are in good agreement as well. We will calculate conversion factors for the graphite calorimeter using our results.

  1. Search for ultra-high energy photons and neutrinos using Telescope Array surface detector

    Directory of Open Access Journals (Sweden)

    Troitsky S.V.

    2013-06-01

    Full Text Available We search for ultra-high energy photons by analyzing geometrical properties of shower fronts of events registered by the Telescope Array surface detector. By making use of an event-by-event statistical method, we derive upper limits on the absolute flux of primary photons with energies above 1019eV, 1019.5eV and above 1020eV based on the three years data from Telescope Array surface detector (May 2008 – May 2011. We report the results of down-going neutrino search based on the analysis of very inclined events.

  2. A methodology for TLD postal dosimetry audit of high-energy radiotherapy photon beams in non-reference conditions.

    Science.gov (United States)

    Izewska, Joanna; Georg, Dietmar; Bera, Pranabes; Thwaites, David; Arib, Mehenna; Saravi, Margarita; Sergieva, Katia; Li, Kaibao; Yip, Fernando Garcia; Mahant, Ashok Kumar; Bulski, Wojciech

    2007-07-01

    A strategy for national TLD audit programmes has been developed by the International Atomic Energy Agency (IAEA). It involves progression through three sequential dosimetry audit steps. The first step audits are for the beam output in reference conditions for high-energy photon beams. The second step audits are for the dose in reference and non-reference conditions on the beam axis for photon and electron beams. The third step audits involve measurements of the dose in reference, and non-reference conditions off-axis for open and wedged symmetric and asymmetric fields for photon beams. Through a co-ordinated research project the IAEA developed the methodology to extend the scope of national TLD auditing activities to more complex audit measurements for regular fields. Based on the IAEA standard TLD holder for high-energy photon beams, a TLD holder was developed with horizontal arm to enable measurements 5cm off the central axis. Basic correction factors were determined for the holder in the energy range between Co-60 and 25MV photon beams. New procedures were developed for the TLD irradiation in hospitals. The off-axis measurement methodology for photon beams was tested in a multi-national pilot study. The statistical distribution of dosimetric parameters (off-axis ratios for open and wedge beam profiles, output factors, wedge transmission factors) checked in 146 measurements was 0.999+/-0.012. The methodology of TLD audits in non-reference conditions with a modified IAEA TLD holder has been shown to be feasible.

  3. The role of high energy photons and particles in accretion flows in active nuclei

    Science.gov (United States)

    Eilek, Jean A.

    1988-01-01

    The creation of high energy pairs and photons in the conversion of gravitational to thermal energy is a process common to most accretion models for active galactic nuclei. These are two observational methods designed to explore this process: direct observations of the hot photons, through hard X-ray and gamma-ray data, and indirect observations of the energetic pairs, through their polarized, nonthermal low frequency radiation. However, interpretation of these observations in terms of the conditions in the inner accretion flow requires understanding of the various processes which modify the pair and photon distributions within the hot, dense core. These processes include opacity effects within the pair/photon plasma, Compton losses on external photons, further acceleration of the pairs and further radiation by the pairs, and the dynamic interaction of the pair/photon plasma with the surrounding gas. Current observational and theoretical work is reviewed and new directions are considered in a search for constraints on or tests of accretion models of active nuclei.

  4. Calculating the X-Ray Fluorescence from the Planet Mercury Due to High-Energy Electrons

    Science.gov (United States)

    Burbine, T. H.; Trombka, J. I.; Bergstrom, P. M., Jr.; Christon, S. P.

    2005-01-01

    The least-studied terrestrial planet is Mercury due to its proximity to the Sun, which makes telescopic observations and spacecraft encounters difficult. Our lack of knowledge about Mercury should change in the near future due to the recent launching of MESSENGER, a Mercury orbiter. Another mission (BepiColombo) is currently being planned. The x-ray spectrometer on MESSENGER (and planned for BepiColombo) can characterize the elemental composition of a planetary surface by measuring emitted fluorescent x-rays. If electrons are ejected from an atom s inner shell by interaction with energetic particles such as photons, electrons, or ions, electrons from an outer shell can transfer to the inner shell. Characteristic x-rays are then emitted with energies that are the difference between the binding energy of the ion in its excited state and that of the ion in its ground state. Because each element has a unique set of energy levels, each element emits x-rays at a unique set of energies. Electrons and ions usually do not have the needed flux at high energies to cause significant x-ray fluorescence on most planetary bodies. This is not the case for Mercury where high-energy particles were detected during the Mariner 10 flybys. Mercury has an intrinsic magnetic field that deflects the solar wind, resulting in a bow shock in the solar wind and a magnetospheric cavity. Electrons and ions accelerated in the magnetosphere tend to follow its magnetic field lines and can impact the surface on Mercury s dark side Modeling has been done to determine if x-ray fluorescence resulting from the impact of high-energy electrons accelerated in Mercury's magnetosphere can be detected by MESSENGER. Our goal is to understand how much bulk chemical information can be obtained from x-ray fluorescence measurements on the dark side of Mercury.

  5. High-Energy Electron Confinement in a Magnetic Cusp Configuration

    Directory of Open Access Journals (Sweden)

    Jaeyoung Park

    2015-06-01

    Full Text Available We report experimental results validating the concept that plasma confinement is enhanced in a magnetic cusp configuration when β (plasma pressure/magnetic field pressure is of order unity. This enhancement is required for a fusion power reactor based on cusp confinement to be feasible. The magnetic cusp configuration possesses a critical advantage: the plasma is stable to large scale perturbations. However, early work indicated that plasma loss rates in a reactor based on a cusp configuration were too large for net power production. Grad and others theorized that at high β a sharp boundary would form between the plasma and the magnetic field, leading to substantially smaller loss rates. While not able to confirm the details of Grad’s work, the current experiment does validate, for the first time, the conjecture that confinement is substantially improved at high β. This represents critical progress toward an understanding of the plasma dynamics in a high-β cusp system. We hope that these results will stimulate a renewed interest in the cusp configuration as a fusion confinement candidate. In addition, the enhanced high-energy electron confinement resolves a key impediment to progress of the Polywell fusion concept, which combines a high-β cusp configuration with electrostatic fusion for a compact, power-producing nuclear fusion reactor.

  6. Experimental investigations of the neutron contamination in high-energy photon fields at medical linear accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Brunckhorst, Elin

    2009-02-26

    The scope of this thesis was to develop a device for the detection of the photoneutron dose inside the high-energy photon field. The photoneutron contamination of a Siemens PRIMUS linear accelerator was investigated in detail in its 15 MV photon mode. The experimental examinations were performed with three ionisation chambers (a tissue equivalent chamber, a magnesium chamber and a {sup 10}B-coated magnesium chamber) and two types of thermoluminescence detectors (enriched with {sup 6}Li and {sup 7}Li, respectively). The detectors have different sensitivities to photons and neutrons and their combination allows the dose separation in a mixed neutron/photon field. The application of the ionisation chamber system, as well as the present TLD system for photoneutron detection in high-energy photon beams is a new approach. The TLD neutron sensitivity was found to be too low for a measurement inside the open photon field and the further investigation focused on the ionisation chambers. The three ionisation chambers were calibrated at different photon and neutron sources and a the borated magnesium chamber showed a very high response to thermal neutrons. For a cross check of the calibration, the three chambers were also used for dose separation of a boron neutron capture therapy beam where the exact determination of the thermal neutron dose is essential. Very accurate results were achieved for the thermal neutron dose component. At the linear accelerator the chamber system was reduced to a paired chamber system utilising the two magnesium chambers, since the fast neutron component was to small to be separated. The neutron calibration of the three chambers could not be applied, instead a conversion of measured thermal neutron signal by the borated chamber to Monte Carlo simulated total neutron dose was performed. Measurements for open fields in solid water and liquid water were performed with the paired chamber system. In larger depths the neutron dose could be determined

  7. High energy density plasma science with an ultrarelativistic electron beam

    Science.gov (United States)

    Joshi, C.; Blue, B.; Clayton, C. E.; Dodd, E.; Huang, C.; Marsh, K. A.; Mori, W. B.; Wang, S.; Hogan, M. J.; O'Connell, C.; Siemann, R.; Watz, D.; Muggli, P.; Katsouleas, T.; Lee, S.

    2002-05-01

    An intense, high-energy electron or positron beam can have focused intensities rivaling those of today's most powerful laser beams. For example, the 5 ps (full-width, half-maximum), 50 GeV beam at the Stanford Linear Accelerator Center (SLAC) at 1 kA and focused to a 3 micron rms spot size gives intensities of >1020 W/cm-2 at a repetition rate of >10 Hz. Unlike a ps or fs laser pulse which interacts with the surface of a solid target, the particle beam can readily tunnel through tens of cm of steel. However, the same particle beam can be manipulated quite effectively by a plasma that is a million times less dense than air! This is because of the incredibly strong collective fields induced in the plasma by the Coulomb force of the beam. The collective fields in turn react back onto the beam leading to many clearly observable phenomena. The beam paraticles can be: (1) Deflected leading to focusing, defocusing, or even steering of the beam; (2) undulated causing the emission of spontaneous betatron x-ray radiation and; (3) accelerated or decelerated by the plasma fields. Using the 28.5 GeV electron beam from the SLAC linac a series of experiments have been carried out that demonstrate clearly many of the above mentioned effects. The results can be compared with theoretical predictions and with two-dimensional and three-dimensional, one-to-one, particle-in-cell code simulations. These phenomena may have practical applications in future technologies including optical elements in particle beam lines, synchrotron light sources, and ultrahigh gradient accelerators.

  8. Predictions for high-energy real and virtual photon-photon scattering from color dipole BFKL-Regge factorization

    Energy Technology Data Exchange (ETDEWEB)

    Nikolaev, N.N. [Forschungszentrum Juelich GmbH (Germany). Inst. fuer Kernphysik; Rossijskaya Akademiya Nauk, Moscow (Russian Federation). Inst. Teoreticheskoj Fiziki; Speth, J. [Forschungszentrum Juelich GmbH (Germany). Inst. fuer Kernphysik; Zoller, V.R. [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation)

    2002-01-01

    High-energy virtual photon-virtual photon scattering can be viewed as an interaction of small size color dipoles from the beam and target photons, which makes {gamma}{sup *}{gamma}{sup *}, {gamma}{sup *}{gamma} scattering at high energies (LEP, LEP200 and NLC) an indispensable probe of the short distance properties of the QCD pomeron exchange. Based on the color dipole representation, we investigate the consequences for the {gamma}{sup *}{gamma}{sup *}, {gamma}{sup *}{gamma} scattering of the incorporation of asymptotic freedom into the BFKL equation which makes the QCD pomeron a series of isolated poles in the angular momentum plane. The emerging color dipole BFKL-Regge factorization allows us to relate in a model-independent way the contributions of each BFKL pole to {gamma}{sup *}{gamma}{sup *}, {gamma}{sup *} {gamma} scattering and DIS off protons. Numerical predictions based on our early works on the color dipole BFKL phenomenology of DIS on protons are in good agreement with the experimental data on the photon structure function F{sub 2{gamma}} and the most recent data on the {gamma}{sup *}{gamma}{sup *} cross section {sigma}{sup {gamma}{sup *}}{sup {gamma}{sup *}}(Y) from the OPAL and L3 experiments at LEP200. We discuss the role of non-perturbative dynamics and predict a pronounced effect of the Regge-factorization breaking due to large unfactorizable non-perturbative corrections to the perturbative vacuum exchange. We comment on the salient features of the BFKL-Regge expansion for {gamma}{sup *}{gamma}{sup *}, {gamma}{sup *}{gamma} scattering including the issue of the decoupling of subleading BFKL poles and the soft plus rightmost hard BFKL pole dominance. (orig.)

  9. Polymers for electronic & photonic application

    CERN Document Server

    Wong, C P

    2013-01-01

    The most recent advances in the use of polymeric materials by the electronic industry can be found in Polymers for Electronic and Photonic Applications. This bookprovides in-depth coverage of photoresis for micro-lithography, microelectronic encapsulants and packaging, insulators, dielectrics for multichip packaging,electronic and photonic applications of polymeric materials, among many other topics. Intended for engineers and scientists who design, process, and manufacturemicroelectronic components, this book will also prove useful for hybrid and systems packaging managers who want to be info

  10. HIGH-ENERGY ELECTRON COOLING BASED ON REALISTIC SIX-DIMENSIONAL DISTRIBUTION OF ELECTRONS

    Energy Technology Data Exchange (ETDEWEB)

    FEDOTOV,A.; BEN-ZVI, I.; ET AL.

    2007-06-25

    The high-energy electron cooling system for RHIC-II is unique compared to standard coolers. It requires bunched electron beam. Electron bunches are produced by an Energy Recovery Linac (ERL), and cooling is planned without longitudinal magnetic field. To address unique features of the RHIC cooler, a generalized treatment of cooling force was introduced in BETACOOE code which allows us to calculate friction force for an arbitrary distribution of electrons. Simulations for RHIC cooler based on electron distribution from ERL are presented.

  11. Test study of boron nitride as a new detector material for dosimetry in high-energy photon beams

    Science.gov (United States)

    Poppinga, D.; Halbur, J.; Lemmer, S.; Delfs, B.; Harder, D.; Looe, H. K.; Poppe, B.

    2017-09-01

    The aim of this test study is to check whether boron nitride (BN) might be applied as a detector material in high-energy photon-beam dosimetry. Boron nitride exists in various crystalline forms. Hexagonal boron nitride (h-BN) possesses high mobility of the electrons and holes as well as a high volume resistivity, so that ionizing radiation in the clinical range of the dose rate can be expected to produce a measurable electrical current at low background current. Due to the low atomic numbers of its constituents, its density (2.0 g cm-3) similar to silicon and its commercial availability, h-BN appears as possibly suitable for the dosimetry of ionizing radiation. Five h-BN plates were contacted to triaxial cables, and the detector current was measured in a solid-state ionization chamber circuit at an applied voltage of 50 V. Basic dosimetric properties such as formation by pre-irradiation, sensitivity, reproducibility, linearity and temporal resolution were measured with 6 MV photon irradiation. Depth dose curves at quadratic field sizes of 10 cm and 40 cm were measured and compared to ionization chamber measurements. After a pre-irradiation with 6 Gy, the devices show a stable current signal at a given dose rate. The current-voltage characteristic up to 400 V shows an increase in the collection efficiency with the voltage. The time-resolved detector current behavior during beam interrupts is comparable to diamond material, and the background current is negligible. The measured percentage depth dose curves at 10 cm  ×  10 cm field size agreed with the results of ionization chamber measurements within  ±2%. This is a first study of boron nitride as a detector material for high-energy photon radiation. By current measurements on solid ionization chambers made from boron nitride chips we could demonstrate that boron nitride is in principle suitable as a detector material for high-energy photon-beam dosimetry.

  12. Test study of boron nitride as a new detector material for dosimetry in high-energy photon beams.

    Science.gov (United States)

    Poppinga, D; Halbur, J; Lemmer, S; Delfs, B; Harder, D; Looe, H K; Poppe, B

    2017-09-05

    The aim of this test study is to check whether boron nitride (BN) might be applied as a detector material in high-energy photon-beam dosimetry. Boron nitride exists in various crystalline forms. Hexagonal boron nitride (h-BN) possesses high mobility of the electrons and holes as well as a high volume resistivity, so that ionizing radiation in the clinical range of the dose rate can be expected to produce a measurable electrical current at low background current. Due to the low atomic numbers of its constituents, its density (2.0 g cm-3) similar to silicon and its commercial availability, h-BN appears as possibly suitable for the dosimetry of ionizing radiation. Five h-BN plates were contacted to triaxial cables, and the detector current was measured in a solid-state ionization chamber circuit at an applied voltage of 50 V. Basic dosimetric properties such as formation by pre-irradiation, sensitivity, reproducibility, linearity and temporal resolution were measured with 6 MV photon irradiation. Depth dose curves at quadratic field sizes of 10 cm and 40 cm were measured and compared to ionization chamber measurements. After a pre-irradiation with 6 Gy, the devices show a stable current signal at a given dose rate. The current-voltage characteristic up to 400 V shows an increase in the collection efficiency with the voltage. The time-resolved detector current behavior during beam interrupts is comparable to diamond material, and the background current is negligible. The measured percentage depth dose curves at 10 cm  ×  10 cm field size agreed with the results of ionization chamber measurements within  ±2%. This is a first study of boron nitride as a detector material for high-energy photon radiation. By current measurements on solid ionization chambers made from boron nitride chips we could demonstrate that boron nitride is in principle suitable as a detector material for high-energy photon-beam dosimetry.

  13. Impact of a plasma channel on the emission of directed high-energy photons in laser-plasma interaction

    Science.gov (United States)

    Jansen, Oliver; Wang, Tao; Toncian, Toma; Stark, David; D'Humieres, Emmanuel; Arefiev, Alexey

    2017-10-01

    Compact sources of directed high-energy photons are of great interest in current research. Common sources of high-energy photons include synchrotrons and other large and expensive accelerators. Laser-plasma interactions promise sources that are significantly smaller and cheaper than conventional ones. However, they come at the cost of producing either only small number of photons or very undirected ones. A recent study shows, that the use of a plasma channel is able to significantly mitigate these problems while producing a large number of high energy, well collimated photons. We provide an analysis on the physical processes, that lead to the formation of strong magnetic fields responsible for this improvement of emission. Furthermore, we investigate the channel properties in relation to a given laser pulse. This research was supported by the National Science Foundation under Grant No. 1632777. Simulations were performed with the EPOCH code using HPC resources provided by the TACC at the University of Texas.

  14. Introduction to electronics and applications in high energy physics

    CERN Multimedia

    CERN. Geneva

    2004-01-01

    Electronics in HEP experiments: specificities and evolution The Art of Electronics: is there something beyond Ohm's law? Basic building blocks of Analog electronics: quickly understanding a schematic Charge preamps, current preamps and future preamps, shaping and the rest Electronics noise: fundamental and practical Evolution of technology: ASICs, FPGAs...

  15. Review of high energy diffraction in real and virtual photon proton scattering at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, G.

    2009-07-15

    The electron-proton collider HERA at DESY opened the door for the study of diffraction in real and virtual photon-proton scattering at center-of-mass energies W up to 250 GeV and for large negative mass squared -Q{sup 2} of the virtual photon up to Q{sup 2}=1600 GeV{sup 2}. At W = 220 GeV and Q{sup 2}=4 GeV{sup 2}, diffraction accounts for about 15% of the total virtual photon proton cross section decreasing to {approx}5% at Q{sup 2}=200 GeV{sup 2}. An overview of the results obtained by the experiments H1 and ZEUS on the production of neutral vector mesons and on inclusive diffraction up to the year 2008 is presented. (orig.)

  16. Generation of multiple excitons in Ag2S quantum dots: Single high-energy versus multiple-photon excitation

    KAUST Repository

    Sun, Jingya

    2014-02-20

    We explored biexciton generation via carrier multiplication (or multiple-exciton generation) by high-energy photons and by multiple-photon absorption in Ag2S quantum dots (QDs) using femtosecond broad-band transient absorption spectroscopy. Irrespective of the size of the QDs and how the multiple excitons are generated in the Ag2S QDs, two distinct characteristic time constants of 9.6-10.2 and 135-175 ps are obtained for the nonradiative Auger recombination of the multiple excitons, indicating the existence of two binding excitons, namely, tightly bound and weakly bound excitons. More importantly, the lifetimes of multiple excitons in Ag 2S QDs were about 1 and 2 orders of magnitude longer than those of comparable size PbS QDs and single-walled carbon nanotubes, respectively. This result is significant because it suggests that by utilizing an appropriate electron acceptor, there is a higher possibility to extract multiple electron-hole pairs in Ag2S QDs, which should improve the performance of QD-based solar cell devices. © 2014 American Chemical Society.

  17. High energy X-ray photon counting imaging using linear accelerator and silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Y., E-mail: cycjty@sophie.q.t.u-tokyo.ac.jp [Department of Bioengineering, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Shimazoe, K.; Yan, X. [Department of Nuclear Engineering and Management, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Ueda, O.; Ishikura, T. [Fuji Electric Co., Ltd., Fuji, Hino, Tokyo 191-8502 (Japan); Fujiwara, T. [National Institute of Advanced Industrial Science and Technology, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Uesaka, M.; Ohno, M. [Nuclear Professional School, the University of Tokyo, 2-22 Shirakata-shirane, Tokai, Ibaraki 319-1188 (Japan); Tomita, H. [Department of Quantum Engineering, Nagoya University, Furo, Chikusa, Nagoya 464-8603 (Japan); Yoshihara, Y. [Department of Nuclear Engineering and Management, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Takahashi, H. [Department of Bioengineering, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Department of Nuclear Engineering and Management, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)

    2016-09-11

    A photon counting imaging detector system for high energy X-rays is developed for on-site non-destructive testing of thick objects. One-dimensional silicon strip (1 mm pitch) detectors are stacked to form a two-dimensional edge-on module. Each detector is connected to a 48-channel application specific integrated circuit (ASIC). The threshold-triggered events are recorded by a field programmable gate array based counter in each channel. The detector prototype is tested using 950 kV linear accelerator X-rays. The fast CR shaper (300 ns pulse width) of the ASIC makes it possible to deal with the high instant count rate during the 2 μs beam pulse. The preliminary imaging results of several metal and concrete samples are demonstrated.

  18. Irradiation of pyrimidine in pure H2O ice with high-energy ultraviolet photons.

    Science.gov (United States)

    Nuevo, Michel; Chen, Yu-Jung; Hu, Wei-Jie; Qiu, Jun-Ming; Wu, Shang-Ruei; Fung, Hok-Sum; Chu, Ching-Chi; Yih, Tai-Sone; Ip, Wing-Huen; Wu, C-Y Robert

    2014-02-01

    The detection of nucleobases, the informational subunits of DNA and RNA, in several meteorites suggests that these compounds of biological interest were formed via astrophysical, abiotic processes. This hypothesis is in agreement with recent laboratory studies of irradiation of pyrimidine in H2O-rich ices with vacuum UV photons emitted by an H2-discharge lamp in the 6.9-11.3 eV (110-180 nm) range at low temperature, shown to lead to the abiotic formation of several compounds including the nucleobases uracil, cytosine, and thymine. In this work, we irradiated H2O:pyrimidine ice mixtures under astrophysically relevant conditions (14 K, ≤10(-9) torr) with high-energy UV photons provided by a synchrotron source in three different ranges: the 0(th) order light (4.1-49.6 eV, 25-300 nm), the He i line (21.2 eV, 58.4 nm), and the He ii line (40.8 eV, 30.4 nm). The photodestruction of pyrimidine was monitored with IR spectroscopy, and the samples recovered at room temperature were analyzed with liquid and gas chromatographies. Uracil and its precursor 4(3H)-pyrimidone were found in all samples, with absolute and relative abundances varying significantly from one sample to another. These results support a scenario in which compounds of biological interest can be formed and survive in environments subjected to high-energy UV radiation fields.

  19. Tomography of high-energy nuclear collisions with photon-hadron correlations.

    Science.gov (United States)

    Zhang, Hanzhong; Owens, J F; Wang, Enke; Wang, Xin-Nian

    2009-07-17

    Within the next-to-leading order (NLO) perturbative QCD (PQCD) parton model, suppression of away-side hadron spectra associated with a high pT photon due to parton energy loss is studied in high-energy heavy-ion collisions. Because of the sharp falloff of the gamma-jet spectrum in momentum imbalance pTjet-pTgamma>0 in NLO PQCD, hadron spectra at large zT=pTh/pTgamma greater than approximately 1 are more susceptible to parton energy loss and therefore are dominated by surface emission of gamma-associated jets with almost no energy loss, whereas small zT hadrons mainly come from the volume emission of jets with reduced energy. These lead to different centrality dependence of the gamma-hadron suppression for different values of zT. Therefore, a complete measurement of the suppression of gamma-triggered hadron spectra allows a true tomographic study of the quark-gluon plasma in high-energy heavy-ion collisions.

  20. Proposal to detect an emission of unusual super-high energy electrons in electron storage rings

    Directory of Open Access Journals (Sweden)

    Da-peng Qian

    2014-01-01

    Full Text Available According to an extended Lorentz–Einstein mass formula taken into the uncertainty principle, it is predicted that the electron beams passing accelerating electric field should with a small probability generate abnormal super-high energy electrons which are much higher than the beam energy. Author’s preliminary experiment result at electron storage ring has hinted these signs, so suggests to more strictly detect this unusual phenomenon, and thus to test the extended mass formula as well as a more perfect special relativity.

  1. Technical Training: ELEC-2005 - Electronics in High Energy Physics

    CERN Multimedia

    Monique Duval

    2005-01-01

    Learning for the LHC! ELEC-2005 is a new course series on modern electronics, given by CERN physicists and engineers within the framework of the 2005 Technical Training Programme, in an extended format of the successful ELEC-2002 course series. This comprehensive course series is designed for people who are not electronics specialists, for example physicists, engineers and technicians working at or visiting the laboratory, who use or will use electronics in their present or future activities, in particular in the context of the LHC accelerator and experiments. ELEC-2005 is composed of four Terms that will run throughout the year: Winter Term: Introduction to electronics in HEP (January-February, 6 lectures) Spring Term: Integrated circuits and VLSI technology for physics (March, 6 lectures) Summer Term: System electronics for physics: Issues (May, 7 lectures) Autumn Term: Electronics applications in HEP experiments (November-December, 10 lectures) Lectures within each Term will take place on Tuesdays an...

  2. Microbunched electron cooling for high-energy hadron beams.

    Science.gov (United States)

    Ratner, D

    2013-08-23

    Electron and stochastic cooling are proven methods for cooling low-energy hadron beams, but at present there is no way of cooling hadrons as they near the TeV scale. In the 1980s, Derbenev suggested that electron instabilities, such as free-electron lasers, could create collective space charge fields strong enough to correct the hadron energies. This Letter presents a variation on Derbenev's electron cooling scheme using the microbunching instability as the amplifier. The large bandwidth of the instability allows for faster cooling of high-density beams. A simple analytical model illustrates the cooling mechanism, and simulations show cooling rates for realistic parameters of the Large Hadron Collider.

  3. Development of dose delivery verification by PET imaging of photonuclear reactions following high energy photon therapy

    Science.gov (United States)

    Janek, S.; Svensson, R.; Jonsson, C.; Brahme, A.

    2006-11-01

    A method for dose delivery monitoring after high energy photon therapy has been investigated based on positron emission tomography (PET). The technique is based on the activation of body tissues by high energy bremsstrahlung beams, preferably with energies well above 20 MeV, resulting primarily in 11C and 15O but also 13N, all positron-emitting radionuclides produced by photoneutron reactions in the nuclei of 12C, 16O and 14N. A PMMA phantom and animal tissue, a frozen hind leg of a pig, were irradiated to 10 Gy and the induced positron activity distributions were measured off-line in a PET camera a couple of minutes after irradiation. The accelerator used was a Racetrack Microtron at the Karolinska University Hospital using 50 MV scanned photon beams. From photonuclear cross-section data integrated over the 50 MV photon fluence spectrum the predicted PET signal was calculated and compared with experimental measurements. Since measured PET images change with time post irradiation, as a result of the different decay times of the radionuclides, the signals from activated 12C, 16O and 14N within the irradiated volume could be separated from each other. Most information is obtained from the carbon and oxygen radionuclides which are the most abundant elements in soft tissue. The predicted and measured overall positron activities are almost equal (-3%) while the predicted activity originating from nitrogen is overestimated by almost a factor of two, possibly due to experimental noise. Based on the results obtained in this first feasibility study the great value of a combined radiotherapy-PET-CT unit is indicated in order to fully exploit the high activity signal from oxygen immediately after treatment and to avoid patient repositioning. With an RT-PET-CT unit a high signal could be collected even at a dose level of 2 Gy and the acquisition time for the PET could be reduced considerably. Real patient dose delivery verification by means of PET imaging seems to be

  4. High energy gain electron beam acceleration by 100TW laser

    Energy Technology Data Exchange (ETDEWEB)

    Kotaki, Hideyuki; Kando, Masaki; Kondo, Shuji; Hosokai, Tomonao; Kanazawa, Shuhei; Yokoyama, Takashi; Matoba, Toru; Nakajima, Kazuhisa [Japan Atomic Energy Research Inst., Kizu, Kyoto (Japan). Kansai Research Establishment

    2001-10-01

    A laser wakefield acceleration experiment using a 100TW laser is planed at JAERI-Kansai. High quality and short pulse electron beams are necessary to accelerate the electron beam by the laser. Electron beam - laser synchronization is also necessary. A microtron with a photocathode rf-gun was prepared as a high quality electron injector. The quantum efficiency (QE) of the photocathode of 2x10{sup -5} was obtained. A charge of 100pC from the microtron was measured. The emittance and pulse width of the electron beam was 6{pi} mm-mrad and 10ps, respectively. In order to produce a short pulse electron beam, and to synchronize between the electron beam and the laser pulse, an inverse free electron laser (IFEL) is planned. One of problems of LWFA is the short acceleration length. In order to overcome the problem, a Z-pinch plasma waveguide will be prepared as a laser wakefield acceleration tube for 1 GeV acceleration. (author)

  5. Direct electron-pair production by high energy heavy charged particles

    Science.gov (United States)

    Takahashi, Y.; Gregory, J. C.; Hayashi, T.; Dong, B. L.

    1989-01-01

    Direct electron pain production via virtual photons by moving charged particles is a unique electro-magnetic process having a substantial dependence on energy. Most electro-magnetic processes, including transition radiation, cease to be sensitive to the incident energy above 10 TeV/AMU. Thus, it is expected, that upon establishment of cross section and detection efficiency of this process, it may provide a new energy measuring technique above 10 TeV/AMU. Three accelerator exposures of emulsion chambers designed for measurements of direct electron-pains were performed. The objectives of the investigation were to provide the fundamental cross-section data in emulsion stacks to find the best-fit theoretical model, and to provide a calibration of measurements of direct electron-pairs in emulsion chamber configurations. This paper reports the design of the emulsion chambers, accelerator experiments, microscope measurements, and related considerations for future improvements of the measurements, and for possible applications to high energy cosmic ray experiments. Also discussed are the results from scanning 56m of emulsion tracks at 1200x magnification so that scanning efficiency is optimized. Measurements of the delta-ray range spectrum were also performed for much shorter track lengths, but with sufficiently large statistics in the number of measured delta-rays.

  6. Consideration of Relativistic Dynamics in High-Energy Electron Coolers

    CERN Document Server

    Bruhwiler, David L

    2005-01-01

    A proposed electron cooler for RHIC would use ~55 MeV electrons to cool fully-ionized 100 GeV/nucleon gold ions.* At two locations in the collider ring, the electrons and ions will co-propagate for ~13 m, with velocities close to c and gamma>100. To lowest-order, one can Lorentz transform all physical quantities into the beam frame and calculate the dynamical friction forces assuming a nonrelativisitc, electrostatic plasma. However, we show that nonlinear space charge forces of the bunched electron beam on the ions must be calculated relativistically, because an electrostatic beam-frame calculation is not valid for such short interaction times. The validity of nonrelativistic friction force calculations must also be considered. Further, the transverse thermal velocities of the high-charge (~20 nC) electron bunch are large enough that some electrons have marginally relativistic velocities, even in the beam frame. Hence, we consider relativistic binary collisions – treating the model problem of ...

  7. A comparison of phantom scatter from flattened and flattening filter free high-energy photon beams.

    Science.gov (United States)

    Richmond, Neil; Allen, Vince; Daniel, Jim; Dacey, Rob; Walker, Chris

    2015-01-01

    Flattening filter free (FFF) photon beams have different dosimetric properties from those of flattened beams. The aim of this work was to characterize the collimator scatter (Sc) and total scatter (Scp) from 3 FFF beams of differing quality indices and use the resulting mathematical fits to generate phantom scatter (Sp) data. The similarities and differences between Sp of flattened and FFF beams are described. Sc and Scp data were measured for 3 flattened and 3 FFF high-energy photon beams (Varian 6 and 10MV and Elekta 6MV). These data were fitted to logarithmic power law functions with 4 numerical coefficients. The agreement between our experimentally determined flattened beam Sp and published data was within ± 1.2% for all 3 beams investigated and all field sizes from 4 × 4 to 40 × 40cm(2). For the FFF beams, Sp was only within 1% of the same flattened beam published data for field sizes between 6 × 6 and 14 × 14cm(2). Outside this range, the differences were much greater, reaching - 3.2%, - 4.5%, and - 4.3% for the fields of 40 × 40cm(2) for the Varian 6-MV, Varian 10-MV, and Elekta 6-MV FFF beams, respectively. The FFF beam Sp increased more slowly with increasing field size than that of the published and measured flattened beam of a similar reference field size quality index, i.e., there is less Phantom Scatter than that found with flattened beams for a given field size. This difference can be explained when the fluence profiles of the flattened and FFF beams are considered. The FFF beam has greatly reduced fluence off axis, especially as field size increases, compared with the flattened beam profile; hence, less scatter is generated in the phantom reaching the central axis. Copyright © 2015 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  8. Medium and high energy electron beam processing system

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, Masayuki [Nissin-High Voltage Co., Ltd., Kyoto (Japan)

    2003-02-01

    Electron Beam Processing System (EPS) is a useful and powerful tool for industrial irradiation process. The specification of EPS is decided by consideration to irradiate what material with how thick and wide, how much dose, how to handle, in what atmosphere. In designing an EPS, it is necessary to consider safety measure such as x-ray shielding, ozone control and interlock system. The initial costs to install typical EPS are estimated for acceleration voltages from 500 kV to 5 MV, including following items; those are electron beam machine, x-ray shielding, auxiliary equipment, material handling, survey for installation, ozone exhaust duct, cooling water system, wiring and piping. These prices are reference only because the price should be changed for each case. The price of x-ray shielding should be changed by construction cost. Auxiliary equipment includes window, cooling blower, ozone exhaust blower and SF6 gas handling equipment. In installation work at site, actual workers of 3 - 4 persons for 2 months are necessary. Material handling system is considered only rolls provided in the shielding room as reference. In addition to the initial installation, operators and workers may be required to wear a personal radiation monitor. An x-ray monitor of suitable design should be installed outside the shield room to monitor x-ray level in the working area. (Y. Tanaka)

  9. Wedge factor constituents of high-energy photon beams: head and phantom scatter dose components.

    Science.gov (United States)

    Heukelom, S; Lanson, J H; Mijnheer, B J

    1994-07-01

    The head and phantom scatter contribution to the output of a treatment machine have been determined for open and wedged 60Co gamma-ray beams and 4, 8, 16 and 25 MV X-ray beams, using an extended and a small-sized phantom. The wedge factor variation with field size and phantom depth have been analysed as a function of both scatter components. For the wedged beams a stronger increase of the head scatter contribution with field size, i.e. 4-9% for field sizes increasing from 5 cm x 5 cm to 20 cm x 20 cm, has been observed compared with open beams. This result indicates that the wedge factor variation with field size is related to a change of the primary photon fluence. Our study shows that the ratio of the head and phantom scatter contribution for the wedged and open beams remains unchanged for all beams except the 4 and 25 MV X-ray beam. This implies that, except for these latter energies, the variation of the wedge factor with phantom depth is determined by the wedge-induced change of the primary photon energy fluence. For the 4 and 25 MV X-ray beam it is shown that the wedge factor is also influenced by a change of the phantom scatter contribution. The wedge factor for the 25 MV X-ray beam is strongly influenced by the electron contamination for phantom depths up to 6 cm. For the 60Co and the 4 MV photon beam it is shown that the wedge factor decreases slightly with increasing source-to-skin distance due to a reduced contribution to the total dose from photons scattered in the wedge. For clinical use, an algorithm is given to calculate the wedge factor variation with field size and phantom depth.

  10. MOSFET sensitivity dependence on integrated dose from high-energy photon beams.

    Science.gov (United States)

    Tanyi, James A; Krafft, Shane P; Hagio, Tomoe; Fuss, Martin; Salter, Bill J

    2008-01-01

    The ability of a commercially available dual bias, dual MOSFET dosimetry system to measure therapeutic doses reproducibly throughout its vendor-defined dose-based lifetime has been evaluated by characterizing its sensitivity variation to integrated/cumulative doses from,high-energy (6 and 15 MV) photon radiotherapy beams. The variation of sensitivity as a function of total integrated dose was studied for three different dose-per-fraction levels; namely, 50, 200, and 1200 cGy/fraction. In standard sensitivity mode (i.e., measurements involving dose-per-fraction levels > or =100 cGy), the response of the MOSFET system to identical irradiations increased with integrated dose for both energies investigated. Dose measurement reproducibility for the low (i.e., 50 cGy) dose fractions was within 2.1% (if the system was calibrated before each in-phantom measurement) and 3.1% [if the system was calibrated prior to first use, with no intermediate calibration(s)]. Similarly, dose measurement reproducibility was between 2.2% and 6.6% for the conventional (i.e., 200 cGy) dose fractions and between 1.8% and 7.9% for escalated (i.e., 1200 cGy) dose fractions. The results of this study suggest that, due to the progressively increasing sensitivity resulting from the dual-MOSFET design, frequent calibrations are required to achieve measurement accuracy of < or =3% (within one standard deviation).

  11. Simulation of electron beam dynamics in a high-energy electron cooler

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, A.V. [BINP, Acad.Lavrentiev, 11, BudkerINP, Novosibirsk, 630090 (Russian Federation)]. E-mail: a.v.ivanov@inp.nsk.su; Panasyuk, V.M. [BINP, Acad.Lavrentiev, 11, BudkerINP, Novosibirsk, 630090 (Russian Federation); Parkhomchuk, V.V. [BINP, Acad.Lavrentiev, 11, BudkerINP, Novosibirsk, 630090 (Russian Federation); Reva, V.B. [BINP, Acad.Lavrentiev, 11, BudkerINP, Novosibirsk, 630090 (Russian Federation); Tiunov, M.A. [BINP, Acad.Lavrentiev, 11, BudkerINP, Novosibirsk, 630090 (Russian Federation)

    2006-03-01

    Electron cooling is now a standard tool for improvement of ion beam parameters in storage rings. In BINP, after successful development of several low-energy electron cooling devices, a project involving a high-energy electron cooler for GSI has been proposed. This cooler has a classical electrostatic scheme with electron energy of up to 8 MeV. Here we present results of numerical simulations of electron beam formation, acceleration and collection for this project. Special attention is paid to a description of the new codes developed in BINP. The electron gun and collector are simulated by the 2D USAM code. This code is modified to calculate collector performance with consideration of secondary emission. The BEAM code is used for simulation of dynamics in the accelerating section. A new 3D electrostatic code, ELEC3D, developed for the simulation of beam dynamics in bends with electrostatic compensation of the centrifugal drift, is described. This code is combined with the existing MAG3D magnetostatic code to provide a universal tool for 3D static calculations.

  12. Radiation-hard Silicon Photonics for Future High Energy Physics Experiments

    CERN Document Server

    AUTHOR|(CDS)2089774; Troska, Jan

    Collisions of proton beams in the Large Hadron Collider at CERN produce very high radiation levels in the innermost parts of the particle detectors and enormous amounts of measurement data. Thousands of radiation-hard optical links based on directly-modulated laser diodes are thus installed in the particle detectors to transmit the measurement data to the processing electronics. The radiation levels in the innermost regions of future particle detectors will be much higher than they are now. Alternative solutions to laser-based radiation-hard optical links have to be found since the performance of laser diodes decreases beyond the operation margin of the system when irradiated to sufficiently high radiation levels. Silicon Photonics (SiPh) is currently being investigated as a promising alternative technology. First tests have indeed shown that SiPh Mach-Zehnder modulators (MZMs) are relatively insensitive to a high neutron fluence. However, they showed a strong degradation when exposed to ionizing radiation. ...

  13. An accelerator scenario for a hard X-ray free electron laser combined with high energy electron radiography

    Science.gov (United States)

    Wei, Tao; Li, Yiding; Yang, Guojun; Pang, Jian; Li, Yuhui; Li, Peng; Pflueger, Joachim; He, Xiaozhong; Lu, Yaxin; Wang, Ke; Long, Jidong; Zhang, Linwen; Wu, Qiang

    2016-08-01

    In order to study the dynamic response of the material and the physical mechanism of fluid dynamics, an accelerator scenario which can be applied to both hard X-ray free electron laser and high energy electron radiography is proposed. This accelerator is mainly composed of a 12 GeV linac, an undulator branch and an eRad beamline. In order to characterize a sample’s dynamic behavior in situ and real-time with XFEL and eRad simultaneously, the linac should be capable of accelerating the two kinds of beam within the same operation mode. Combining in-vacuum and tapering techniques, the undulator branch can produce more than 1011 photons per pulse in 0.1% bandwidth at 42 keV. Finally, an eRad amplifying beamline with 1:10 ratio is proposed as an important complementary tool for the wider view field and density identification ability. Supported by China Academy of Engineering Physics (2014A0402016) and Institute of Fluid Physics (SFZ20140201)

  14. Photon and dilepton production in high-energy heavy-ion collisions

    Indian Academy of Sciences (India)

    2015-05-07

    May 7, 2015 ... Hard production of photons and dileptons. One of the big successes in electromagnetic radiation measurements in relativistic heavy- ion collisions is the observation of high pT direct photons that are produced in the initial hard scattering [9]. Figures 4a and 4b show the latest direct photon pT spectra in Au+ ...

  15. High Energy Cosmic Electrons: Messengers from Nearby Cosmic Ray Sources or Dark Matter?

    Science.gov (United States)

    Moiseev, Alexander

    2011-01-01

    This slide presentation reviews the recent discoveries by the Large Area Telescope (LAT) and the Gamma-ray Burst Monitor (GBM) on board the Fermi Gamma-Ray Telescope in reference to high energy cosmic electrons, and whether their source is cosmic rays or dark matter. Specific interest is devoted to Cosmic Ray electrons anisotropy,

  16. Electron-photon shower distribution function tables for lead, copper and air absorbers

    CERN Document Server

    Messel, H

    2013-01-01

    Electron-Photon Shower Distribution Function: Tables for Lead, Copper and Air Absorbers presents numerical results of the electron-photon shower distribution function for lead, copper, and air absorbers. Electron or photon interactions, including Compton scattering, elastic Coulomb scattering, and the photo-electric effect, are taken into account in the calculations. This book consists of four chapters and begins with a review of both theoretical and experimental work aimed at deducing the characteristics of the cascade produced from the propagation of high energy electrons and photons through

  17. Peripheral dose measurement in high-energy photon radiotherapy with the implementation of MOSFET.

    Science.gov (United States)

    Vlachopoulou, Vassiliki; Malatara, Georgia; Delis, Harry; Theodorou, Kiki; Kardamakis, Dimitrios; Panayiotakis, George

    2010-11-28

    To study the peripheral dose (PD) from high-energy photon beams in radiotherapy using the metal oxide semiconductor field effect transistor (MOSFET) dose verification system. The radiation dose absorbed by the MOSFET detector was calculated taking into account the manufacturer's Correction Factor, the Calibration Factor and the threshold voltage shift. PD measurements were carried out for three different field sizes (5 cm × 5 cm, 10 cm × 10 cm and 15 cm × 15 cm) and for various depths with the source to surface distance set at 100 cm. Dose measurements were realized on the central axis and then at distances (1 to 18 cm) parallel to the edge of the field, and were expressed as the percentage PD (% PD) with respect to the maximum dose (d(max)). The accuracy of the results was evaluated with respect to a calibrated 0.3 cm(3) ionization chamber. The reproducibility was expressed in terms of standard deviation (s) and coefficient of variation. % PD is higher near the phantom surface and drops to a minimum at the depth of d(max), and then tends to become constant with depth. Internal scatter radiation is the predominant source of PD and the depth dependence is determined by the attenuation of the primary photons. Closer to the field edge, where internal scatter from the phantom dominates, the % PD increases with depth because the ratio of the scatter to primary increases with depth. A few centimeters away from the field, where collimator scatter and leakage dominate, the % PD decreases with depth, due to attenuation by the water. The % PD decreases almost exponentially with the increase of distance from the field edge. The decrease of the % PD is more than 60% and can reach up to 90% as the measurement point departs from the edge of the field. For a given distance, the % PD is significantly higher for larger field sizes, due to the increase of the scattering volume. Finally, the measured PD obtained with MOSFET is higher than that obtained with an ionization chamber

  18. Detection methods for cereal grains treated with low and high energy electrons

    Energy Technology Data Exchange (ETDEWEB)

    Cutrubinis, Mihalis; Delincee, Henry E-mail: henry.delincee@bfe.uni-karlsruhe.de; Stahl, Mario; Roeder, Olaf; Schaller, H.J

    2005-04-01

    Cereal grains can be treated with low energy (<300 keV) or high energy (1-10 MeV) electrons for decontamination of phytopathogenic and spoilage organisms. In this preliminary study, wheat and barley samples were treated with low energy electrons of 145 keV or high energy electrons of 10 MeV. To identify the electron treatment, different detection methods have been investigated: (1) photostimulated luminescence (PSL), (2) thermoluminescence (TL), (3) electron spin resonance (ESR) and (4) DNA Comet Assay. These four methods are already standardised at a European level and are now adopted as general Codex methods for detection of irradiated foodstuffs. The results suggest that the most suitable detection methods for electron-treated grains are the PSL and TL methods. The results from the other two methods (ESR and Comet Assay) are not so promising because they seem only to be applicable in special cases.

  19. Direct photon production in high-energy heavy-ion collisions

    Energy Technology Data Exchange (ETDEWEB)

    Manko, V.; Aggarwal, M.M.; Agnihotri, A.; Ahammed, Z.; Angelis, A.L.S.; Antonenko, V.; Arefiev, V.; Astakhov, V.; Avdeitchikov, V.; Awes, T.C.; Baba, P.V.K.S.; Badyal, S.K.; Baldine, A.; Barabach, L.; Barlag, C.; Bathe, S.; Batiounia, B.; Bernier, T.; Bhalla, K.B.; Bhatia, V.S.; Blume, C.; Bock, R.; Bohne, E.-M.; Boeroecz, Z.; Bucher, D.; Buijs, A.; Buesching, H.; Carlen, L.; Chalyshev, V.; Chattopadhyay, S.; Cherbatchev, R.; Chujo, T.; Claussen, A.; Das, A.C.; Decowski, M.P.; Djordjadze, V.; Donni, P.; Doubovik, I.; Dutt, S.; Majumdar, M.R. Dutta; El Chenawi, K.; Eliseev, S.; Enosawa, K.; Foka, P.; Fokin, S.; Frolov, V.; Ganti, M.S.; Garpman, S.; Gavrischuk, O.; Geurts, F.J.M.; Ghosh, T.K.; Glasow, R.; Gupta, S. K.; Guskov, B.; Gustafsson, H. A.; Gutbrod, H. H.; Higuchi, R.; Hrivnacova, I.; Ippolitov, M.; Kalechofsky, H.; Kamermans, R.; Kampert, K.-H.; Karadjev, K.; Karpio, K.; Kato, S.; Kees, S.; Kim, H.; Kolb, B. W.; Kosarev, I.; Koutcheryaev, I.; Kruempel, T.; Kugler, A.; Kulinich, P.; Kurata, M.; Kurita, K.; Kuzmin, N.; Langbein, I.; Lebedev, A.; Lee, Y.Y.; Loehner, H.; Luquin, L.; Mahapatra, D.P.; Martin, M.; Maximov, A.; Mehdiyev, R.; Mgebrichvili, G.; Miake, Y.; Mikhalev, D.; Mir, Md.F.; Mishra, G.C.; Miyamoto, Y.; Morrison, D.; Mukhopadhyay, D. S.; Myalkovski, V.; Naef, H.; Nandi, B. K.; Nayak, S. K.; Nayak, T. K.; Neumaier, S.; Nianine, A.; Nikitine, V.; Nikolaev, S.; Nilsson, P.; Nishimura, S.; Nomokonov, P.; Nystrand, J.; Obenshain, F.E.; Oskarsson, A.; Otterlund, I.; Pachr, M.; Parfenov, A.; Pavliouk, S.; Peitzmann, T.; Petracek, V.; Plasil, F.; Pinanaud, W.; Purschke, M.L.; Raeven, B.; Rak, J.; Raniwala, R.; Raniwala, S.; Ramamurthy, V.S.; Rao, N.K.; Retiere, F.; Reygers, K.; Roland, G.; Rosselet, L.; Roufanov, I.; Roy, C.; Rubio, J.M.; Sako, H.; Sambyal, S.S.; Santo, R.; Sato, S.; Schlagheck, H.; Schmidt, H.-R.; Shabratova, G.; Shah, T.H.; Sibiriak, I.; Siemiarczuk, T.; Silvermyr, D.; Sinha, B.C.; Slavine, N.; Soederstroem, K. [and others

    1999-07-26

    Direct thermal photons in the p{sub t} range of 0 - 5 GeV/c are expected to provide a sensitive probe of the hot dense matter formed in the early stage of relativistic heavy ion collisions. The production of single photons in 158 AGeV Pb+Pb interactions has been studied with the 10080 detector lead glass calorimeter of the WA98 experiment at CERN. Neutral {pi}{sup 0} cross section has been measured via its two-photon decay branch. At p{sub t} {>=}{approx}GeV/c single photon yields of {approx}20% of the decay photon yields are observed consistently with different photon identification criteria both for the peripheral and central events.

  20. Search for ultra high energy primary photons at the Pierre Auger Observatory

    Directory of Open Access Journals (Sweden)

    Colalillo Roberta

    2016-01-01

    Full Text Available The Pierre Auger Observatory, located in Argentina, provides an unprecedented integrated aperture in the search for primary photons with energy above 1017 eV over a large portion of the southern sky. Such photons can be detected in principle via the air showers they initiate at such energies, using the complement of Auger Observatory detectors. We discuss the results obtained in diffuse and directional searches for primary photons in the EeV energy range.

  1. High-energy photoemission spectroscopy for investigating bulk electronic structures of strongly correlated systems

    Energy Technology Data Exchange (ETDEWEB)

    Sekiyama, Akira, E-mail: sekiyama@mp.es.osaka-u.ac.jp [Division of Materials Physics, Graduate School of Engineering Science, Osaka University, Toyonaka 560-8531, Osaka (Japan); SPring-8/RIKEN, Sayo 679-5148, Hyogo (Japan)

    2016-04-15

    Progress of high-energy photoemission spectroscopy for investigating the bulk electronic structures of strongly correlated electron systems is reviewed. High-resolution soft X-ray photoemission has opened the door for revealing the bulk strongly correlated spectral functions overcoming the surface contributions. More bulk-sensitive hard X-ray photoemission spectroscopy (HAXPES) enables us to study the electronic structure with negligible surface contribution. The recent development of the polarization-dependent HAXPES is also described in this short review.

  2. An insertion to eliminate horizontal temperature of high energy electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Burov, A.V. [AN SSSR, Novosibirsk (Russian Federation). Inst. Yadernoj Fiziki; Danilov, V.V. [AN SSSR, Novosibirsk (Russian Federation). Inst. Yadernoj Fiziki

    1998-03-16

    High energy electron cooling with a circulated electron bunch could significantly increase the luminosity of hadron colliders. One of the significant obstacles is high horizontal temperature of electron bunches, suppressing dramatically calculated cooling rates. Recently, a transformation of betatron coordinates and angles for elimination of the radial temperature was found. In our paper, we present a simple scheme to make up this transformation by thin quadruples, drifts and a solenoid.

  3. Numerical study of the electron and muon lateral distribution in atmospheric showers of high energy cosmic rays

    Directory of Open Access Journals (Sweden)

    Georgios Atreidis

    2017-01-01

    Full Text Available The lateral distribution of an atmospheric shower depends on the characteristics of the high energy interactions and the type of the primary particle. The influence of the primary particle in the secondary development of the shower into the atmosphere, is studied by analyzing the lateral distribution of electron and muon showers having as primary particle, proton, photon or iron nucleus. This study of the lateral distribution can provide useful conclusions for the mass and energy of the primary particle. This paper compares the data that we get from simulations with CORSIKA program with experimental data and the theoretical NKG function expressing lateral electron and muon distribution. Then we modify the original NKG function to fit better to the simulation data and propose a method for determining the mass of the original particle started the atmospheric shower.

  4. Variably spaced superlattice energy filter, a new device design concept for high-energy electron injection

    Science.gov (United States)

    Summers, C. J.; Brennan, K. F.

    1986-01-01

    A new variably spaced superlattice energy filter is proposed which provides high-energy injection of electrons into a bulk semiconductor layer based on resonant tunneling between adjacent quantum well levels which are brought into alignment by an applied bias. Applications of this concept to a variety of optoelectronic devices and to thin-film electroluminescent devices and photodetectors are discussed.

  5. LHC collision event at CMS showing four high energy electrons (CMS Higgs search)

    CERN Multimedia

    CMS Collaboration

    2011-01-01

    11sec animation of a Higgs->ZZ->4e candidate in CMS. Real CMS proton-proton collision events in which 4 high energy electrons (orange lines and towers) are observed. The event shows characteristics expected from the decay of a Higgs boson but is also consistent with background Standard Model physics processes.

  6. Testing quantum chromodynamics in electron-positron annihilation at high energies. [Review

    Energy Technology Data Exchange (ETDEWEB)

    Brown, L.S.

    1979-01-01

    Various measures of the distribution of hadronic energy produced in high energy electron-positron annihilation provide precise tests of the promising fundamental theory of hadronic physics, quantum chromodynamics. Recent work at the University of Washington on such energy cross sections is reviewed.

  7. Dependence of Xmax and multiplicity of electron and muon on different high energy interaction models

    Directory of Open Access Journals (Sweden)

    G Rastegarzadeh

    2010-06-01

    Full Text Available Different high energy interaction models are the applied in CORSIKA code to simulate Extensive Air Showers (EAS generated by Cosmic Rays (CR. In this work the effects of QGSJET01, QGSJETII, DPMJET, SIBYLL models on Xmax and multiplicity of secondary electrons and muons at observation level are studied.

  8. 1979 international symposium on lepton and photon interactions at high energies

    Energy Technology Data Exchange (ETDEWEB)

    Kirk, T.B.W.; Abarbanel, H.D.I.

    1979-01-01

    This symposium on Leptons and Photons is ninth in the series of biannual meetings which began at Cambridge, Massachusetts, in 1963. Abstracts of individual items from the symposium were prepared separately for the data base. (GHT)

  9. Calculation of perturbation correction factors for some reference dosimeters in high-energy photon beams with the Monte Carlo code PENELOPE.

    Science.gov (United States)

    Mazurier, J; Gouriou, J; Chauvenet, B; Barthe, J

    2001-06-01

    The BNM-LNHB (formerly BNM-LPRI, the French national standard laboratory for ionizing radiation) is equipped with a SATURNE 43 linear accelerator (GE Medical Systems) dedicated to establishing national references of absorbed dose to water for high-energy photon and electron beams. These standards are derived from a dose measurement with a graphite calorimeter and a transfer procedure to water using Fricke dosimeters. This method has already been used to obtain the reference of absorbed dose to water for cobalt-60 beams. The correction factors rising from the perturbations generated by the dosimeters were determined by Monte Carlo calculations. To meet these applications, the Monte Carlo code PENELOPE was used and user codes were specially developed. The first step consisted of simulating the electron and photon showers produced by primary electrons within the accelerator head to determine the characteristics of the resulting photon beams and absorbed dose distributions in a water phantom. These preliminary computations were described in a previous paper. The second step, described in this paper, deals with the calculation of the perturbation correction factors of the graphite calorimeter and of Fricke dosimeters. To point out possible systematic biases, these correction factors were calculated with another Monte Carlo code, EGS4, widely used for years in the field of dose metrology applications. Comparison of the results showed no significant bias. When they were possible, experimental verifications confirmed the calculated values.

  10. Current status of free radicals and electronically excited metastable species as high energy propellants

    Science.gov (United States)

    Rosen, G.

    1973-01-01

    A survey is presented of free radicals and electronically excited metastable species as high energy propellants for rocket engines. Nascent or atomic forms of diatomic gases are considered free radicals as well as the highly reactive diatomic triatomic molecules that posess unpaired electrons. Manufacturing and storage problems are described, and a review of current experimental work related to the manufacture of atomic hydrogen propellants is presented.

  11. Low-energy photons in high-energy photon fields--Monte Carlo generated spectra and a new descriptive parameter.

    Science.gov (United States)

    Chofor, Ndimofor; Harder, Dietrich; Willborn, Kay; Rühmann, Antje; Poppe, Björn

    2011-09-01

    The varying low-energy contribution to the photon spectra at points within and around radiotherapy photon fields is associated with variations in the responses of non-water equivalent dosimeters and in the water-to-material dose conversion factors for tissues such as the red bone marrow. In addition, the presence of low-energy photons in the photon spectrum enhances the RBE in general and in particular for the induction of second malignancies. The present study discusses the general rules valid for the low-energy spectral component of radiotherapeutic photon beams at points within and in the periphery of the treatment field, taking as an example the Siemens Primus linear accelerator at 6 MV and 15 MV. The photon spectra at these points and their typical variations due to the target system, attenuation, single and multiple Compton scattering, are described by the Monte Carlo method, using the code BEAMnrc/EGSnrc. A survey of the role of low energy photons in the spectra within and around radiotherapy fields is presented. In addition to the spectra, some data compression has proven useful to support the overview of the behaviour of the low-energy component. A characteristic indicator of the presence of low-energy photons is the dose fraction attributable to photons with energies not exceeding 200 keV, termed P(D)(200 keV). Its values are calculated for different depths and lateral positions within a water phantom. For a pencil beam of 6 or 15 MV primary photons in water, the radial distribution of P(D)(200 keV) is bellshaped, with a wide-ranging exponential tail of half value 6 to 7 cm. The P(D)(200 keV) value obtained on the central axis of a photon field shows an approximately proportional increase with field size. Out-of-field P(D)(200 keV) values are up to an order of magnitude higher than on the central axis for the same irradiation depth. The 2D pattern of P(D)(200 keV) for a radiotherapy field visualizes the regions, e.g. at the field margin, where changes of

  12. Radiation hygienization of cattle and swine slurry with high energy electron beam

    Science.gov (United States)

    Skowron, Krzysztof; Olszewska, Halina; Paluszak, Zbigniew; Zimek, Zbigniew; Kałuska, Iwona; Skowron, Karolina Jadwiga

    2013-06-01

    The research was carried out to assess the efficiency of radiation hygienization of cattle and swine slurry of different density using the high energy electron beam based on the inactivation rate of Salmonella ssp, Escherichia coli, Enterococcus spp and Ascaris suum eggs. The experiment was conducted with use of the linear electron accelerator Elektronika 10/10 in Institute of Nuclear Chemistry and Technology in Warsaw. The inoculated slurry samples underwent hygienization with high energy electron beam of 1, 3, 5, 7 and 10 kGy. Numbers of reisolated bacteria were determined according to the MPN method, using typical microbiological media. Theoretical lethal doses, D90 doses and hygienization efficiency of high energy electron beam were determined. The theoretical lethal doses for all tested bacteria ranged from 3.63 to 8.84 kGy and for A. suum eggs from 4.07 to 5.83 kGy. Salmonella rods turned out to be the most sensitive and Enterococcus spp were the most resistant to electron beam hygienization. The effectiveness or radiation hygienization was lower in cattle than in swine slurry and in thick than in thin one. Also the species or even the serotype of bacteria determined the dose needed to inactivation of microorganisms.

  13. Probing plasmonic nanostructures by photons and electrons

    DEFF Research Database (Denmark)

    Kneipp, Katrin; Kneipp, Harald; Kneipp, Janina

    2015-01-01

    We discuss recent developments for studying plasmonic metal nanostructures. Exploiting photons and electrons opens up new capabilities to probe the complete plasmon spectrum including bright and dark modes and related local optical fields at subnanometer spatial resolution. This comprehensive...

  14. LIGO Triggered Search for Coincidence with High Energy Photon Survey Missions

    Science.gov (United States)

    Camp, Jordan

    2009-01-01

    LIGO is about to begin a new, higher sensitivity science run, where gravitational detection is plausible. A possible candidate for detection is a compact binary merger, which would also be likely to emit a high energy electromagnetic signal. Coincident observation of the gw signal from a compact merger with an x-ray or gamma-ray signal would add considerable weight to the claim for gw detection. In this talk I will consider the possibility of using LIGO triggers with time and sky position to perform a coincident analysis of EM signals from the RXTE, SWIFT, and FERMI missions.

  15. High energy supercontinuum sources using tapered photonic crystal fibers for multispectral photoacoustic microscopy

    DEFF Research Database (Denmark)

    Bondu, Magalie; Brooks, Christopher; Jakobsen, Christian

    2016-01-01

    We demonstrate a record bandwidth high energy supercontinuum source suitable for multispectral photoacoustic microscopy. The source has more than 150  nJ/10  nm150  nJ/10  nm bandwidth over a spectral range of 500 to 1600 nm. This performance is achieved using a carefully designed fiber taper...... with large-core input for improved power handling and small-core output that provides the desired spectral range of the supercontinuum source....

  16. High-energy electron-induced damage production at room temperature in aluminum-doped silicon

    Science.gov (United States)

    Corbett, J. W.; Cheng, L. J.; Jaworowski, A.; Karins, J. P.; Lee, Y. H.; Lindstroem, L.; Mooney, P. M.; Oehrlen, G.; Wang, K. L.

    1979-01-01

    DLTS and EPR measurements are reported on aluminum-doped silicon that was irradiated at room temperature with high-energy electrons. Comparisons are made to comparable experiments on boron-doped silicon. Many of the same defects observed in boron-doped silicon are also observed in aluminum-doped silicon, but several others were not observed, including the aluminum interstitial and aluminum-associated defects. Damage production modeling, including the dependence on aluminum concentration, is presented.

  17. A Polarized High-Energy Photon Beam for Production of Exotic Mesons

    Energy Technology Data Exchange (ETDEWEB)

    Senderovich, Igor [Univ. of Connecticut, Storrs, CT (United States)

    2012-01-01

    This work describes design, prototyping and testing of various components of the Jefferson Lab Hall D photon beamline. These include coherent bremsstrahlung radiators to be used in this facility for generating the photon beam, a fine resolution hodoscope for the facility's tagging spectrometer, and a photon beam position sensor for stabilizing the beam on a collimator. The principal instrumentation project was the hodoscope: its design, implementation and beam testing will be thoroughly described. Studies of the coherent bremsstrahlung radiators involved X-ray characterization of diamond crystals to identify the appropriate line of manufactured radiators and the proper techniques for thinning them to the desired specification of the beamline. The photon beam position sensor project involved completion of a designed detector and its beam test. The results of these shorter studies will also be presented. The second part of this work discusses a Monte Carlo study of a possible photo-production and decay channel in the GlueX experiment that will be housed in the Hall D facility. Specifically, the γ p → Xp → b1 π → ω π+1 π-1 channel was studied including its Amplitude Analysis. This exercise attempted to generate a possible physics signal, complete with internal angular momentum states, and be able to reconstruct the signal in the detector and find the proper set of JPC quantum numbers through an amplitude fit. Derivation of the proper set of amplitudes in the helicity basis is described, followed by a discussion of the implementation, generation of the data sets, reconstruction techniques, the amplitude fit and results of this study.

  18. Charged Particle, Photon Multiplicity, and Transverse Energy Production in High-Energy Heavy-Ion Collisions

    Directory of Open Access Journals (Sweden)

    Raghunath Sahoo

    2015-01-01

    Full Text Available We review the charged particle and photon multiplicities and transverse energy production in heavy-ion collisions starting from few GeV to TeV energies. The experimental results of pseudorapidity distribution of charged particles and photons at different collision energies and centralities are discussed. We also discuss the hypothesis of limiting fragmentation and expansion dynamics using the Landau hydrodynamics and the underlying physics. Meanwhile, we present the estimation of initial energy density multiplied with formation time as a function of different collision energies and centralities. In the end, the transverse energy per charged particle in connection with the chemical freeze-out criteria is discussed. We invoke various models and phenomenological arguments to interpret and characterize the fireball created in heavy-ion collisions. This review overall provides a scope to understand the heavy-ion collision data and a possible formation of a deconfined phase of partons via the global observables like charged particles, photons, and the transverse energy measurement.

  19. Numerical simulation of inducing characteristics of high energy electron beam plasma for aerodynamics applications

    Science.gov (United States)

    Deng, Yongfeng; Jiang, Jian; Han, Xianwei; Tan, Chang; Wei, Jianguo

    2017-04-01

    The problem of flow active control by low temperature plasma is considered to be one of the most flourishing fields of aerodynamics due to its practical advantages. Compared with other means, the electron beam plasma is a potential flow control method for large scale flow. In this paper, a computational fluid dynamics model coupled with a multi-fluid plasma model is established to investigate the aerodynamic characteristics induced by electron beam plasma. The results demonstrate that the electron beam strongly influences the flow properties, not only in the boundary layers, but also in the main flow. A weak shockwave is induced at the electron beam injection position and develops to the other side of the wind tunnel behind the beam. It brings additional energy into air, and the inducing characteristics are closely related to the beam power and increase nonlinearly with it. The injection angles also influence the flow properties to some extent. Based on this research, we demonstrate that the high energy electron beam air plasma has three attractive advantages in aerodynamic applications, i.e. the high energy density, wide action range and excellent action effect. Due to the rapid development of near space hypersonic vehicles and atmospheric fighters, by optimizing the parameters, the electron beam can be used as an alternative means in aerodynamic steering in these applications.

  20. Measurement of high-energy electrons by means of a Cherenkov detector in ISTTOK tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Jakubowski, L., E-mail: lech.Jjakubowski@ipj.gov.p [Andrzej Soltan Institute for Nuclear Studies (IPJ), 05-400 Otwock-Swierk (Poland); Zebrowski, J. [Andrzej Soltan Institute for Nuclear Studies (IPJ), 05-400 Otwock-Swierk (Poland); Plyusnin, V.V. [Association Euratom/IST, Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Av. Rovisco Pais, 1049 - 001 Lisboa (Portugal); Malinowski, K.; Sadowski, M.J.; Rabinski, M. [Andrzej Soltan Institute for Nuclear Studies (IPJ), 05-400 Otwock-Swierk (Poland); Fernandes, H.; Silva, C.; Duarte, P. [Association Euratom/IST, Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Av. Rovisco Pais, 1049 - 001 Lisboa (Portugal)

    2010-10-15

    The paper concerns detectors of the Cherenkov radiation which can be used to measure high-energy electrons escaping from short-living plasma. Such detectors have high temporal (about 1 ns) and spatial (about 1 mm) resolution. The paper describes a Cherenkov-type detector which was designed, manufactured and installed in the ISTTOK tokamak in order to measure fast runaway electrons. The radiator of that detector was made of an aluminium nitride (AlN) tablet with a light-tight filter on its front surface. Cherenkov signals from the radiator were transmitted through an optical cable to a fast photomultiplier. It made possible to perform direct measurements of the runaway electrons of energy above 80 keV. The measured energy values and spatial characteristics of the recorded electrons appeared to be consistent with results of numerical modelling of the runaway electron generation process in the ISTTOK tokamak.

  1. Real and virtual photons in weak leptonic processes at high energies

    CERN Document Server

    Dolgov, A D; Zakharov, V I

    1972-01-01

    Weak-electromagnetic processes in colliding ee (e mu , mu mu ) beams at high energy are discussed (s approximately=(2*200 GeV)/sup 2/). Radiative and higher order weak corrections to the amplitude of reaction e/sup +/e/sup -/ to nu nu gamma are considered. Interference between weak and electromagnetic amplitudes of e/sup +/e/sup -/ scattering and e/sup +/e/sup -/ to mu /sup +/ mu /sup -/ annihilation is calculated. The formulae obtained are applicable also to muon induced reactions. Logarithmic terms in radiative corrections to the cross sections of the processes mentioned above are calculated. Corrections to weak amplitudes due to hadron contribution are discussed.

  2. Feasibility study on temporal-resolved diffraction of high-energy electrons produced in femtosecond laser-plasmas

    CERN Document Server

    Zhang Jun; Cang Yu; Chen Qing; Peng Lian Mao; Wang Huai Bin; Zhong Jia Yong

    2002-01-01

    The high-energy electrons can be produced in the interaction between intense ultra-short laser pulses and Al targets. The diffraction may take place when high-energy electrons pass through an Al single crystal. Feasibility is studied using such diffraction as a method to analyze the structures of crystals

  3. November 2013 Analysis of High Energy Electrons on the Japan Experimental Module (JEM: Kibo)

    Science.gov (United States)

    Badavi, Francis F.; Matsumoto, Haruhisa; Koga, Kiyokazu; Mertens, Christopher J.; Slaba, Tony C.; Norbury, John W.

    2015-01-01

    Albedo (precipitating/splash) electrons, created by galactic cosmic rays (GCR) interaction with the upper atmosphere move upwards away from the surface of the earth. In the past validation work these particles were often considered to have negligible contribution to astronaut radiation exposure on the International Space Station (ISS). Estimates of astronaut exposure based on the available Computer Aided Design (CAD) models of ISS consistently underestimated measurements onboard ISS when the contribution of albedo particles to exposure were neglected. Recent measurements of high energy electrons outside ISS Japan Experimental Module (JEM) using Exposed Facility (EF), Space Environment Data Acquisition Equipment - Attached Payload (SEDA-AP) and Standard DOse Monitor (SDOM), indicates the presence of high energy electrons at ISS altitude. In this presentation the status of these energetic electrons is reviewed and mechanism for the creation of these particles inside/outside South Atlantic Anomaly (SAA) region explained. In addition, limited dosimetric evaluation of these electrons at 600 MeV and 10 GeV is presented.

  4. Wedge factor constituents of high energy photon beams: field size and depth dependence.

    Science.gov (United States)

    Heukelom, S; Lanson, J H; Mijnheer, B J

    1994-01-01

    Wedge factors have been determined as a function of field size and phantom depth for a 60Co gamma-ray beam and X-ray beams in the range from 4 MV to 25 MV. The results show an increase of the wedge factor with field size, up to 9.1% for the 25 MV X-ray beam. The magnitude of this increase is a linear function of the product of that part of the irradiated wedge volume that can be observed from the point of measurement, its mass energy-absorption coefficient and mass density. This relationship is independent of the photon beam energy, the type of wedge material and the wedge angle. Differences in variation of the amount of backscatter to the monitor with field size for the open and wedged photon beam yielded only a minor influence, up to 0.7%. For the 4-16 MV X-ray beams the wedge factor increases linearly with phantom depth, almost independently of field size. For the 60Co gamma-ray beam and the 25 MV X-ray beam the wedge factor variation is a more complicated function of phantom depth for a particular field size.

  5. High-energy photon activation tandem mass spectrometry provides unprecedented insights into the structure of highly sulfated oligosaccharides extracted from macroalgal cell walls.

    Science.gov (United States)

    Ropartz, David; Giuliani, Alexandre; Hervé, Cécile; Geairon, Audrey; Jam, Murielle; Czjzek, Mirjam; Rogniaux, Hélène

    2015-01-20

    Extreme ultraviolet photon activation tandem mass spectrometry (MS) at 69 nm (18 eV) was used to characterize mixtures of oligo-porphyrans, a class of highly sulfated oligosaccharides. Porphyrans, hybrid polymers whose structures are far from known, continue to provide a challenge for analytical method development. Activation by 18 eV photons led to a rich fragmentation of the oligo-porphyrans, with many cross-ring and glycosidic cleavages. In contrast to multistage MSn strategies such as activated electron photodetachment dissociation, a single step of irradiation by energetic UV of multiply charged anions led to a complete fragmentation of the oligo-porphyrans. In both ionization modes, the sulfate groups were retained on the backbone, which allowed the pattern of these modifications along the porphyran backbone to be described in unprecedented detail. Many structures released by the enzymatic degradation of the porphyran were completely resolved, including isomers. This work extends the existing knowledge of the structure of porphyrans. In addition, it provides a new demonstration of the potential of activation by high-energy photons for the structural analysis of oligosaccharides, even in unseparated mixtures, with a particular focus on sulfated compounds.

  6. The observations of high energy electrons and associated waves by DSP satellites during substorm

    Energy Technology Data Exchange (ETDEWEB)

    Cao Jinbin [Key Laboratory of Space Weather, Center for Space Science and Applied Research, Chinese Academy of Sciences, Beijing, 100080 (China); Yang Junying; Yan Chunxiao [Key Laboratory of Space Weather, Center for Space Science and Applied Research, Chinese Academy of Sciences, Beijing, 100080 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100039 (China); Li Liyuan [Key Laboratory of Space Weather, Center for Space Science and Applied Research, Chinese Academy of Sciences, Beijing, 100080 (China)

    2007-04-15

    Double Star Program (DSP) is a CNSA-ESA cooperation mission. DSP consists of two satellites: Equatorial satellite (TC-1) and Polar satellite (TC-2). This paper presents important observations of long duration loss of high energetic electrons and relevant waves in the recovery phase of substorm, that are made by LFEW and HEED of the polar satellite of DSP (TC-2). The HEED of TC-2 observed a loss event of high energetic electrons which lasted about 4 minute. At the same time, the LFEW of TC-2 observed a wave burst. The wave burst began 1 minute earlier than the loss event of energetic electrons. The frequency of waves ranges form 600 Hz to over 10 kHz. The analyses of wave characteristics indicate that the wave was whistler-mode. Thus it is very possible that the loss of high energy electrons was caused by wave activities through wave-particle interactions.

  7. Emittance evolution of a tightly focused electron bunch with high energy spread

    CERN Document Server

    Rossi, A R

    2011-01-01

    The production of a self injected high energy electron beam from laser-plasma interaction is one of the goals at the LI2FE infrastructure at LNF. The formation and acceleration of a beam produced with the experimental setting available in Frascati has been simulated by C. Benedetti et al. by means of the code AlaDyn [1]; the results, shown in Figure 1, foresee that the bunch should have a total charge of about 3.5 nC, a transverse size of few microns and a very broad spectrum, ranging from a few MeV up to about 1 GeV, in agreement with other numerical and experimental results produced world wide. In particular, a neatly separated charge portion at high energy is present (Figure 2), whose main parameters are reported in Table 1, which constitutes the most interesting product of the plasma based accelerator.

  8. An empirical model of the high-energy electron environment at Jupiter

    Science.gov (United States)

    Soria-Santacruz, M.; Garrett, H. B.; Evans, R. W.; Jun, I.; Kim, W.; Paranicas, C.; Drozdov, A.

    2016-10-01

    We present an empirical model of the energetic electron environment in Jupiter's magnetosphere that we have named the Galileo Interim Radiation Electron Model version-2 (GIRE2) since it is based on Galileo data from the Energetic Particle Detector (EPD). Inside 8RJ, GIRE2 adopts the previously existing model of Divine and Garrett because this region was well sampled by the Pioneer and Voyager spacecraft but poorly covered by Galileo. Outside of 8RJ, the model is based on 10 min averages of Galileo EPD data as well as on measurements from the Geiger Tube Telescope on board the Pioneer spacecraft. In the inner magnetosphere the field configuration is dipolar, while in the outer magnetosphere it presents a disk-like structure. The gradual transition between these two behaviors is centered at about 17RJ. GIRE2 distinguishes between the two different regions characterized by these two magnetic field topologies. Specifically, GIRE2 consists of an inner trapped omnidirectional model between 8 to 17RJ that smoothly joins onto the original Divine and Garrett model inside 8RJ and onto a GIRE2 plasma sheet model at large radial distances. The model provides a complete picture of the high-energy electron environment in the Jovian magnetosphere from ˜1 to 50RJ. The present manuscript describes in great detail the data sets, formulation, and fittings used in the model and provides a discussion of the predicted high-energy electron fluxes as a function of energy and radial distance from the planet.

  9. Suppression of high-energy electrons generated in both disrupting and sustained MST tokamak plasmas

    Science.gov (United States)

    Pandya, M. D.; Chapman, B. E.; Munaretto, S.; Cornille, B. S.; McCollam, K. J.; Sovinec, C. R.; Dubois, A. M.; Almagri, A. F.; Goetz, J. A.

    2017-10-01

    High-energy electrons appearing during MST tokamak plasma disruptions are rapidly lost from the plasma due apparently to internal MHD activity. Work has just recently begun on generating and diagnosing disruptions in MST tokamak plasmas. Initial measurements show the characteristic drop in central temperature and density preceding a quench of the plasma current. This corresponds to a burst of dominantly n=1 MHD activity, which is accompanied by a short-lived burst of high-energy electrons. The short-lived nature of these electrons is suspected to be due to stochastic transport associated with the increased MHD. Earlier work shows that runaway electrons generated in low density, sustained plasmas are suppressed by a sufficiently large m=3 RMP in plasmas with q(a) MST's thick conducting shell. With an m=3 RMP, the degree of runaway suppression increases with RMP amplitude, while an m=1 RMP has little effect on the runaways. Nonlinear MHD modeling with NIMROD of these MST plasmas indicates increased stochasticity with an m=3 RMP, while no such increase in stochasticity is observed with an m=1 RMP. Work supported by US DOE.

  10. Time-dose relationship of erythema in high energy photon irradiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hidetoshi (Gifu Prefectural Tajimi Hospital (Japan)); Sakuma, Sadayuki

    1992-01-01

    Skin doses of 100 patients who were treated with high energy ionizing irradiation during conventional irradiation therapy were measured by thermoluminescence dosimeter (TLD). In 87 of the 100 patients, acute hyperemic change of the skin (erythema) of the irradiated region was observed. In the other 13 patients, alopetia of the scalp was observed. The following conclusions were reached. The time-dose relationship was linear when erythema tolerance was used as an index, but not when alopecia was used. The tolerance dose for erythema was lower than previously reported. The slope of the isoeffect curve on the log-log plot of total absorbed skin dose against total number of days after the first irradiation was 0.68 when erythema was used as an index. This number is larger than previously reported results. We considered that erythema is significantly influenced by fraction size and that hyperfractionation is a promising method of irradiation, especially in Japan. Combined use of chemotherapeutic agents, such as 5-FU, accelerated erythema. The slope of combined treatment was 0.86. Observing acute hyperemic change of skin is considered to be a useful method of investigating the combined effects of chemotherapeutic agents on irradiation. (author).

  11. A Monte Carlo study of high-energy photon transport in matter: application for multiple scattering investigation in Compton spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Brancewicz, Marek, E-mail: brancew@spring8.or.jp; Itou, Masayoshi; Sakurai, Yoshiharu [Japan Synchrotron Radiation Research Institute (JASRI), 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan)

    2016-01-01

    The new efficient Monte Carlo procedure for multiple scattering simulation in Compton experiments is presented. The simulation algorithm has proved its advantage in restricted geometry experiments. The first results of multiple scattering simulations of polarized high-energy X-rays for Compton experiments using a new Monte Carlo program, MUSCAT, are presented. The program is developed to follow the restrictions of real experimental geometries. The new simulation algorithm uses not only well known photon splitting and interaction forcing methods but it is also upgraded with the new propagation separation method and highly vectorized. In this paper, a detailed description of the new simulation algorithm is given. The code is verified by comparison with the previous experimental and simulation results by the ESRF group and new restricted geometry experiments carried out at SPring-8.

  12. Anomalous gauge couplings of the Higgs boson at high energy photon colliders

    Science.gov (United States)

    Han, Tao; Kuang, Yu-Ping; Zhang, Bin

    2006-03-01

    We study the sensitivity of testing the anomalous gauge couplings gHVV’s of the Higgs boson in the formulation of linearly realized gauge symmetry via the processes γγ→ZZ and γγ→WWWW at polarized and unpolarized photon colliders based on e+e- linear colliders of c.m. energies 500 GeV, 1 TeV, and 3 TeV. Signals beyond the standard model (SM) and SM backgrounds are carefully studied. We propose certain kinematic cuts to suppress the standard model backgrounds. For an integrated luminosity of 1ab-1, we show that (a) γγ→ZZ can provide a test of gHγγ to the 3σ sensitivity of O(10-3 10-2)TeV-1 at a 500 GeV ILC, and O(10-3)TeV-1 at a 1 TeV ILC and a 3 TeV CLIC, and (b) γγ→WWWW at a 3 TeV CLIC can test all the anomalous couplings gHVV’s to the 3σ sensitivity of O(10-3 10-2)TeV-1.

  13. Dose-calculation algorithms in the context of inhomogeneity corrections for high energy photon beams.

    Science.gov (United States)

    Papanikolaou, Niko; Stathakis, Sotirios

    2009-10-01

    Radiation therapy has witnessed a plethora of innovations and developments in the past 15 years. Since the introduction of computed tomography for treatment planning there has been a steady introduction of new methods to refine treatment delivery. Imaging continues to be an integral part of the planning, but also the delivery, of modern radiotherapy. However, all the efforts of image guided radiotherapy, intensity-modulated planning and delivery, adaptive radiotherapy, and everything else that we pride ourselves in having in the armamentarium can fall short, unless there is an accurate dose-calculation algorithm. The agreement between the calculated and delivered doses is of great significance in radiation therapy since the accuracy of the absorbed dose as prescribed determines the clinical outcome. Dose-calculation algorithms have evolved greatly over the years in an effort to be more inclusive of the effects that govern the true radiation transport through the human body. In this Vision 20/20 paper, we look back to see how it all started and where things are now in terms of dose algorithms for photon beams and the inclusion of tissue heterogeneities. Convolution-superposition algorithms have dominated the treatment planning industry for the past few years. Monte Carlo techniques have an inherent accuracy that is superior to any other algorithm and as such will continue to be the gold standard, along with measurements, and maybe one day will be the algorithm of choice for all particle treatment planning in radiation therapy.

  14. High Energy Electron Signals from Dark Matter Annihilation in the Sun

    Energy Technology Data Exchange (ETDEWEB)

    Schuster, Philip; /SLAC; Toro, Natalia; /Stanford U., ITP; Weiner, Neal; Yavin, Itay; /New York U., CCPP

    2012-04-09

    In this paper we discuss two mechanisms by which high energy electrons resulting from dark matter annihilations in or near the Sun can arrive at the Earth. Specifically, electrons can escape the sun if DM annihilates into long-lived states, or if dark matter scatters inelastically, which would leave a halo of dark matter outside of the sun. Such a localized source of electrons may affect the spectra observed by experiments with narrower fields of view oriented towards the sun, such as ATIC, differently from those with larger fields of view such as Fermi. We suggest a simple test of these possibilities with existing Fermi data that is more sensitive than limits from final state radiation. If observed, such a signal will constitute an unequivocal signature of dark matter.

  15. REEFER: a digital computer program for the simulation of high energy electron tubes. [Reefer

    Energy Technology Data Exchange (ETDEWEB)

    Boers, J.E.

    1976-11-01

    A digital computer program for the simulation of very high-energy electron and ion beams is described. The program includes space-charge effects through the solution of Poisson's equation and magnetic effects (both induced and applied) through the relativistic trajectory equations. Relaxation techniques are employed while alternately computing electric fields and trajectories. Execution time is generally less than 15 minutes on a CDC 6600 digital computer. Either space-charge-limited or field-emission sources may be simulated. The input data is described in detail and an example data set is included.

  16. Testing QCD in Photon-Photon Interactions

    OpenAIRE

    Soldner-Rembold, Stefan

    1998-01-01

    At high energies photon-photon interactions are dominated by quantum fluctuations of the photons into fermion-antifermion pairs and into vector mesons. This is called photon structure. Electron-positron collisions at LEP are an ideal laboratory for studying photon structure and for testing QCD.

  17. Measurement of the primary and scatter dose in high energy photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Van der Linden, P.M. [Catharina Ziekenhuis, Eindhoven (Netherlands). Radiotherapy Dept.; Tiourina, T.B.; Dries, W.

    1995-12-01

    A method is presented to measure the primary and scatter components separately in a water tank using a small cylindrical absorber. Results from this experiment are compared with Monte Carlo calculations. The measurement setup consists of a small cylindrical absorber placed on a central axis of the beam a few centimetres above the radiation detector. Both absorber and detector move along the central axis while absorbed dose is registered. As the primary radiation is fully blocked, only scatter component is measured when a cylindrical absorber is used. Measurements in open fields result in the total absorbed dose being the sum of primary and scatter components. The primary dose component can be derived by substraction. Absorbers with different diameters are used. With decreasing dimensions the relative contribution of the dose due to scatter radiation increases. A steep increase is observed when the range of laterally scattered electrons becomes comparable with the radius of the absorber. Two different Monte Carlo simulations have been performed: with and without secondary electron transport. The data obtained for the former case perfectly agrees with the experiment. The situation where the secondary electron is assumed zero (i.e. local energy deposition) simulates the Cunningham model. Our results show that the Cunningham model predicts lower scatter component under the block edge which can be important for these applications.

  18. Pc5 modulation of high energy electron precipitation: particle interaction regions and scattering efficiency

    Directory of Open Access Journals (Sweden)

    E. Spanswick

    2005-07-01

    Full Text Available Using the NORSTAR riometer and CANOPUS magnetometer arrays we have investigated the modulation of high energy electron precipitation by ULF waves in the Pc5 frequency band. We conducted two separate studies of Pc5 activity in the riometers. The first is an independent survey of three riometer stations in the Churchill line (one at each sub-auroral, auroral, and typical polar cap boundary latitudes in which we identified all riometer Pc5-band pulsations over 11 years. All had a corresponding magnetometer pulsation implying that a magnetic pulsation, is a necessary condition for a riometer pulsation (in the Pc5 Band. We find seasonal and latitude dependencies in the occurrence of riometer pulsations. By a factor of two, there are more riometer pulsations occurring in the fall-winter than the spring-summer. At higher latitudes there is a tendency towards noon pulsations during the spring-summer, suggesting that the criteria for riometer pulsations is affected by the dipole tilt. Our second study was based on the previous magnetometer study of Baker et al. (2003. Using the database of Pc5 activity from that study we were able to select the riometer Pc5 pulsations which adhere to the strict Pc5 definition in the magnetometer. We find that roughly 95% of the riometer pulsations occurred in the morning sector compared to 70% in the magnetometer. Given a magnetometer pulsation at Gillam in the morning sector, there is a 70% chance of there being a corresponding riometer pulsation. The morning sector probabilities at Rankin (geomagnetic (PACE latitude 74° and Pinawa (61° are 3% and 5%, respectively. These statistics suggest there is a localized region in the pre-noon magnetosphere where Pc5 band ULF activity can modulate high energy electron precipitation. We also find that riometer pulsations display a Kp selection towards mid (i.e. 3–4 activity levels which mimics the product of the Kp dependence of high-energy electron fluxes on the dawn side

  19. Pc5 modulation of high energy electron precipitation: particle interaction regions and scattering efficiency

    Directory of Open Access Journals (Sweden)

    E. Spanswick

    2005-07-01

    Full Text Available Using the NORSTAR riometer and CANOPUS magnetometer arrays we have investigated the modulation of high energy electron precipitation by ULF waves in the Pc5 frequency band. We conducted two separate studies of Pc5 activity in the riometers. The first is an independent survey of three riometer stations in the Churchill line (one at each sub-auroral, auroral, and typical polar cap boundary latitudes in which we identified all riometer Pc5-band pulsations over 11 years. All had a corresponding magnetometer pulsation implying that a magnetic pulsation, is a necessary condition for a riometer pulsation (in the Pc5 Band. We find seasonal and latitude dependencies in the occurrence of riometer pulsations. By a factor of two, there are more riometer pulsations occurring in the fall-winter than the spring-summer. At higher latitudes there is a tendency towards noon pulsations during the spring-summer, suggesting that the criteria for riometer pulsations is affected by the dipole tilt. Our second study was based on the previous magnetometer study of Baker et al. (2003. Using the database of Pc5 activity from that study we were able to select the riometer Pc5 pulsations which adhere to the strict Pc5 definition in the magnetometer. We find that roughly 95% of the riometer pulsations occurred in the morning sector compared to 70% in the magnetometer. Given a magnetometer pulsation at Gillam in the morning sector, there is a 70% chance of there being a corresponding riometer pulsation. The morning sector probabilities at Rankin (geomagnetic (PACE latitude 74° and Pinawa (61° are 3% and 5%, respectively. These statistics suggest there is a localized region in the pre-noon magnetosphere where Pc5 band ULF activity can modulate high energy electron precipitation. We also find that riometer pulsations display a Kp selection towards mid (i.e. 3–4 activity levels which mimics the product of the Kp dependence of high-energy

  20. GRB 110709A, 111117A, AND 120107A: FAINT HIGH-ENERGY GAMMA-RAY PHOTON EMISSION FROM FERMI-LAT OBSERVATIONS AND DEMOGRAPHIC IMPLICATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Zheng Weikang; Akerlof, Carl W.; McKay, Timothy A. [Department of Physics, University of Michigan, 450 Church Street, Ann Arbor, MI 48109 (United States); Pandey, Shashi B. [Aryabhatta Research Institute of Observational Sciences, Manora Peak, Nainital 263129 (India); Zhang Binbin [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA 16802 (United States); Zhang Bing [Department of Physics and Astronomy, University of Nevada, Las Vegas, NV 89154 (United States); Sakamoto, Takanori, E-mail: zwk@umich.edu [Center for Research and Exploration in Space Science and Technology (CRESST), NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

    2012-09-01

    Launched on 2008 June 11, the Large Area Telescope (LAT) instrument on board the Fermi Gamma-ray Space Telescope has provided a rare opportunity to study high-energy photon emission from gamma-ray bursts (GRBs). Although the majority of such events (27) have been identified by the Fermi-LAT Collaboration, four were uncovered by using more sensitive statistical techniques. In this paper, we continue our earlier work by finding three more GRBs associated with high-energy photon emission, GRB 110709A, 111117A, and 120107A. To systematize our matched filter approach, a pipeline has been developed to identify these objects in nearly real time. GRB 120107A is the first product of this analysis procedure. Despite the reduced threshold for identification, the number of GRB events has not increased significantly. This relative dearth of events with low photon number prompted a study of the apparent photon number distribution. We find an extremely good fit to a simple power law with an exponent of -1.8 {+-} 0.3 for the differential distribution. As might be expected, there is a substantial correlation between the number of lower energy photons detected by the Gamma-ray Burst Monitor (GBM) and the number observed by LAT. Thus, high-energy photon emission is associated with some but not all of the brighter GBM events. Deeper studies of the properties of the small population of high-energy emitting bursts may eventually yield a better understanding of these entire phenomena.

  1. Exclusive vector mesons at high energies: from photon-proton to proton-proton and nucleus-nucleus collisions

    Directory of Open Access Journals (Sweden)

    Schäfer Wolfgang

    2012-12-01

    Full Text Available Photoproduction of vector mesons has been studied since the 1960’s and was instrumental in establishing the hadronic structure of the photon and the concept of vectormeson dominance. More recently our knowledge on vector meson photoproduction has been furthered by experiments at the HERA accelerator. Total cross sections ans well as a number of kinematical distributions have been measured from light to heavy vector mesons. These experiments have been a testbed of ideas on the production mechanism, the QCD Pomeron exchange. In particular in varying the mass of the vector meson we can study the Pomeron exchange from the soft to the perturbatively hard regimes. The production mechanism also contains information on the quark-antiquark wave function of the produced meson. High energy protons or ions are the source of a flux of Weizsäcker-Williams photons, which can be utilized to study the photoproduction of vector mesons also at the Tevatron and LHC colliders. We discuss how information on the small-x gluon distribution in protons in nuclei can be obtained. Besides this intrinsic interest in vector meson production, a precise knowledge thereof is also necessary for odderon searches. In this regard, we discuss also transverse momentum distributions including absorption effects.

  2. Mesospheric ozone destruction by high-energy electron precipitation associated with pulsating aurora

    Science.gov (United States)

    Turunen, Esa; Kero, Antti; Verronen, Pekka T.; Miyoshi, Yoshizumi; Oyama, Shin-Ichiro; Saito, Shinji

    2016-10-01

    Energetic particle precipitation into the upper atmosphere creates excess amounts of odd nitrogen and odd hydrogen. These destroy mesospheric and upper stratospheric ozone in catalytic reaction chains, either in situ at the altitude of the energy deposition or indirectly due to transport to other altitudes and latitudes. Recent statistical analysis of satellite data on mesospheric ozone reveals that the variations during energetic electron precipitation from Earth's radiation belts can be tens of percent. Here we report model calculations of ozone destruction due to a single event of pulsating aurora early in the morning on 17 November 2012. The presence of high-energy component in the precipitating electron flux (>200 keV) was detected as ionization down to 68 km altitude, by the VHF incoherent scatter radar of European Incoherent Scatter (EISCAT) Scientific Association (EISCAT VHF) in Tromsø, Norway. Observations by the Van Allen Probes satellite B showed the occurrence of rising tone lower band chorus waves, which cause the precipitation. We model the effect of high-energy electron precipitation on ozone concentration using a detailed coupled ion and neutral chemistry model. Due to a 30 min, recorded electron precipitation event we find 14% odd oxygen depletion at 75 km altitude. The uncertainty of the higher-energy electron fluxes leads to different possible energy deposition estimates during the pulsating aurora event. We find depletion of odd oxygen by several tens of percent, depending on the precipitation characteristics used in modeling. The effect is notably maximized at the sunset time following the occurrence of the precipitation.

  3. HIGH-ENERGY X-RAY PINHOLE CAMERA FOR HIGH-RESOLUTION ELECTRON BEAM SIZE MEASUREMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Yang, B.; Morgan, J.; Lee, S.H.; Shang, H.

    2017-03-25

    The Advanced Photon Source (APS) is developing a multi-bend achromat (MBA) lattice based storage ring as the next major upgrade, featuring a 20-fold reduction in emittance. Combining the reduction of beta functions, the electron beam sizes at bend magnet sources may be reduced to reach 5 – 10 µm for 10% vertical coupling. The x-ray pinhole camera currently used for beam size monitoring will not be adequate for the new task. By increasing the operating photon energy to 120 – 200 keV, the pinhole camera’s resolution is expected to reach below 4 µm. The peak height of the pinhole image will be used to monitor relative changes of the beam sizes and enable the feedback control of the emittance. We present the simulation and the design of a beam size monitor for the APS storage ring.

  4. Optical Response of Metakaolin after Ultraviolet and High Energy Electron Exposure

    Directory of Open Access Journals (Sweden)

    B. T. Cesul

    2014-01-01

    Full Text Available Metakaolin, which is part of a class of inorganic polymers called geopolymers, is being tested currently for its use as a lightweight mirror material in spacecraft applications. Metakaolin, as with most geopolymers, has the advantages of low initial coefficient of thermal expansion, easy preparation at room temperature and pressure, and high specific strength. Even though metakaolin has been known as a structural material for millennia, it has not been properly vetted for use as a material in spacecraft applications, especially with respect to exposure to its environments. This research highlights one particular aspect of response to the space environment; that is, how do the optical properties of metakaolin change after subjugation to bombardment by ultraviolet and high energy electron radiation? These two radiation sources are common in low earth orbit and a primary cause of degradation of organic polymers in space. Photospectroscopic analysis showed that ultraviolet in combination with high energy electrons causes changes in the metakaolin which need to be accounted for due to their potential impacts on the thermal management of a spacecraft and during application in composite mirror structures.

  5. Dosimetric characterization of CVD diamonds in photon, electron and proton beams

    Energy Technology Data Exchange (ETDEWEB)

    Cirrone, G.A.P. [Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali dei Sud, Catania (Italy); Cuttone, G. [Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali dei Sud, Catania (Italy); Lo Nigro, S. [Dipartimento di Fisica ed Astronomia, Universita degli Studi di Catania, Italia (Italy); Mongelli, V. [Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali dei Sud, Catania (Italy); Raffaele, L. [Istituto di Radiologia, Universita degli Studi di Catania (Italy); Sabini, M.G. [Rem Radioterapia S.r.l., Catania (Italy)

    2006-01-15

    The purpose of this work is the characterization, in an on line configuration, of the dosimetric response of a commercial CVD diamond. The study shows the possibility of using CVD diamond for dosimetric purposes with clinical, high-energy electron (4-15 MeV), photon (6-15 MV) and proton (62 MeV) beams.

  6. Enigmatic electrons, photons, and ``empty`` waves

    Energy Technology Data Exchange (ETDEWEB)

    MacGregor, M.H.

    1995-08-22

    A spectroscopic analysis is made of electrons and photons from the standpoint of physical realism. In this conceptual framework, moving particles are portrayed as localized entities which are surrounded by ``empty`` waves. A spectroscopic model for the electron Stands as a guide for a somewhat similar, but in essential respects radically different, model for the photon. This leads in turn to a model for the ``zeron``. the quantum of the empty wave. The properties of these quanta mandate new basis states, and hence an extension of our customary framework for dealing with them. The zeron wave field of a photon differs in one important respect from the standard formalism for an electromagnetic wave. The vacuum state emerges as more than just a passive bystander. Its polarization properties provide wave stabilization, particle probability distributions, and orbit quantization. Questions with regard to special relativity are discussed.

  7. Sensitivity of the IceCube detector for ultra-high energy electron neutrino events

    Energy Technology Data Exchange (ETDEWEB)

    Voigt, Bernhard

    2008-07-16

    IceCube is a neutrino telescope currently under construction in the glacial ice at South Pole. At the moment half of the detector is installed, when completed it will instrument 1 km{sup 3} of ice providing a unique experimental setup to detect high energy neutrinos from astrophysical sources. In this work the sensitivity of the complete IceCube detector for a diffuse electron-neutrino flux is analyzed, with a focus on energies above 1 PeV. Emphasis is put on the correct simulation of the energy deposit of electromagnetic cascades from charged-current electron-neutrino interactions. Since existing parameterizations lack the description of suppression effects at high energies, a simulation of the energy deposit of electromagnetic cascades with energies above 1 PeV is developed, including cross sections which account for the LPM suppression of bremsstrahlung and pair creation. An attempt is made to reconstruct the direction of these elongated showers. The analysis presented here makes use of the full charge waveform recorded with the data acquisition system of the IceCube detector. It introduces new methods to discriminate efficiently between the background of atmospheric muons, including muon bundles, and cascade signal events from electron-neutrino interactions. Within one year of operation of the complete detector a sensitivity of 1.5.10{sup -8}E{sup -2} GeVs{sup -1}sr{sup -1}cm{sup -2} is reached, which is valid for a diffuse electron neutrino flux proportional to E{sup -2} in the energy range from 16 TeV to 13 PeV. Sensitivity is defined as the upper limit that could be set in absence of a signal at 90% confidence level. Including all neutrino flavors in this analysis, an improvement of at least one order of magnitude is expected, reaching the anticipated performance of a diffuse muon analysis. (orig.)

  8. PHOTON09. Proceedings of the international conference on the structure and interactions of the photon including the 18th international workshop on photon-photon collisions and the international workshop on high energy photon linear colliders

    Energy Technology Data Exchange (ETDEWEB)

    Behnke, Olaf; Diehl, Markus; Schoerner-Sadenius, Thomas; Steinbrueck, Georg (eds.)

    2010-01-15

    The following topics were dealt with: Electroweak and new physics, photon-collider technology, low-energy photon experiments, prompt photons, photon structure, jets and heavy flavours, vacuum polarization and light-by-light scattering, small-x processes, diffraction, total cross sections, exclusive channels and resonances, photons in astroparticle physics. (HSI)

  9. Luminescent tracks of high-energy photoemitted electrons accelerated by plasmonic fields

    Directory of Open Access Journals (Sweden)

    Di Vece Marcel

    2015-12-01

    Full Text Available The emission of an electron from a metal nanostructure under illumination and its subsequent acceleration in a plasmonic field forms a platform to extend these phenomena to deposited nanoparticles, which can be studied by state-of-the-art confocal microscopy combined with femtosecond optical excitation. The emitted and accelerated electrons leave defect tracks in the immersion oil, which can be revealed by thermoluminescence. These photographic tracks are read out with the confocal microscope and have a maximum length of about 80 μm, which corresponds to a kinetic energy of about 100 keV. This energy is consistent with the energy provided by the intense laser pulse combined with plasmonic local field enhancement. The results are discussed within the context of the rescattering model by which electrons acquire more energy. The visualization of electron tracks originating from plasmonic field enhancement around a gold nanoparticle opens a new way to study with confocal microscopy both the plasmonic properties of metal nano objects as well as high energy electron interaction with matter.

  10. Advanced High Energy Density Secondary Batteries with Multi‐Electron Reaction Materials

    Science.gov (United States)

    Luo, Rui; Huang, Yongxin; Li, Li

    2016-01-01

    Secondary batteries have become important for smart grid and electric vehicle applications, and massive effort has been dedicated to optimizing the current generation and improving their energy density. Multi‐electron chemistry has paved a new path for the breaking of the barriers that exist in traditional battery research and applications, and provided new ideas for developing new battery systems that meet energy density requirements. An in‐depth understanding of multi‐electron chemistries in terms of the charge transfer mechanisms occuring during their electrochemical processes is necessary and urgent for the modification of secondary battery materials and development of secondary battery systems. In this Review, multi‐electron chemistry for high energy density electrode materials and the corresponding secondary battery systems are discussed. Specifically, four battery systems based on multi‐electron reactions are classified in this review: lithium‐ and sodium‐ion batteries based on monovalent cations; rechargeable batteries based on the insertion of polyvalent cations beyond those of alkali metals; metal–air batteries, and Li–S batteries. It is noted that challenges still exist in the development of multi‐electron chemistries that must be overcome to meet the energy density requirements of different battery systems, and much effort has more effort to be devoted to this. PMID:27840796

  11. Advanced High Energy Density Secondary Batteries with Multi-Electron Reaction Materials.

    Science.gov (United States)

    Chen, Renjie; Luo, Rui; Huang, Yongxin; Wu, Feng; Li, Li

    2016-10-01

    Secondary batteries have become important for smart grid and electric vehicle applications, and massive effort has been dedicated to optimizing the current generation and improving their energy density. Multi-electron chemistry has paved a new path for the breaking of the barriers that exist in traditional battery research and applications, and provided new ideas for developing new battery systems that meet energy density requirements. An in-depth understanding of multi-electron chemistries in terms of the charge transfer mechanisms occuring during their electrochemical processes is necessary and urgent for the modification of secondary battery materials and development of secondary battery systems. In this Review, multi-electron chemistry for high energy density electrode materials and the corresponding secondary battery systems are discussed. Specifically, four battery systems based on multi-electron reactions are classified in this review: lithium- and sodium-ion batteries based on monovalent cations; rechargeable batteries based on the insertion of polyvalent cations beyond those of alkali metals; metal-air batteries, and Li-S batteries. It is noted that challenges still exist in the development of multi-electron chemistries that must be overcome to meet the energy density requirements of different battery systems, and much effort has more effort to be devoted to this.

  12. Electron pair creation by photons

    NARCIS (Netherlands)

    Holtwijk, Theodoor

    1960-01-01

    In our experiment on the creation of electron pairs a 5 MeV betatron was used as radiation source and a cloud chamber (with magnetic field) was used as detection instrument. The experimental arrangement is described in section 2.1. The cloud chamber was of the overcompression type so that the

  13. New Results on High Energy Cosmic Ray Electrons Observed with Fermi LAT and Their Implications on the Models of Pulsars

    Science.gov (United States)

    Moiseev, Alexander

    2010-01-01

    This viewgraph presentation describes, in detail, the Fermi Large Area Telescope (LAT) and GLAST Burst Monitor (GBM). Observations made from the June 11, 2008 launch and a discussion of observations made of high energy cosmic ray electrons is also presented.

  14. Radial Moment Calculations of Coupled Electron-Photon Beams

    Energy Technology Data Exchange (ETDEWEB)

    FRANKE,BRIAN C.; LARSEN,EDWARD W.

    2000-07-19

    The authors consider the steady-state transport of normally incident pencil beams of radiation in slabs of material. A method has been developed for determining the exact radial moments of 3-D beams of radiation as a function of depth into the slab, by solving systems of 1-D transport equations. They implement these radial moment equations in the ONEBFP discrete ordinates code and simulate energy-dependent, coupled electron-photon beams using CEPXS-generated cross sections. Modified P{sub N} synthetic acceleration is employed to speed up the iterative convergence of the 1-D charged particle calculations. For high-energy photon beams, a hybrid Monte Carlo/discrete ordinates method is examined. They demonstrate the efficiency of the calculations and make comparisons with 3-D Monte Carlo calculations. Thus, by solving 1-D transport equations, they obtain realistic multidimensional information concerning the broadening of electron-photon beams. This information is relevant to fields such as industrial radiography, medical imaging, radiation oncology, particle accelerators, and lasers.

  15. The CALorimetric Electron Telescope (CALET for high-energy astroparticle physics on the International Space Station

    Directory of Open Access Journals (Sweden)

    Adriani O.

    2015-01-01

    Full Text Available The CALorimetric Electron Telescope (CALET is a space experiment, currently under development by Japan in collaboration with Italy and the United States, which will measure the flux of cosmic-ray electrons (and positrons up to 20 TeV energy, of gamma rays up to 10 TeV, of nuclei with Z from 1 to 40 up to 1 PeV energy, and will detect gamma-ray bursts in the 7 keV to 20 MeV energy range during a 5 year mission. These measurements are essential to investigate possible nearby astrophysical sources of high energy electrons, study the details of galactic particle propagation and search for dark matter signatures. The main detector of CALET, the Calorimeter, consists of a module to identify the particle charge, followed by a thin imaging calorimeter (3 radiation lengths with tungsten plates interleaving scintillating fibre planes, and a thick energy measuring calorimeter (27 radiation lengths composed of lead tungstate logs. The Calorimeter has the depth, imaging capabilities and energy resolution necessary for excellent separation between hadrons, electrons and gamma rays. The instrument is currently being prepared for launch (expected in 2015 to the International Space Station ISS, for installation on the Japanese Experiment Module - Exposure Facility (JEM-EF.

  16. Changes in the surface electronic states of semiconductor fine particles induced by high energy ion irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Yamaki, Tetsuya; Asai, Keisuke; Ishigure, Kenkichi [Tokyo Univ. (Japan); Shibata, Hiromi

    1997-03-01

    The changes in the surface electronic states of Q-sized semiconductor particles in Langmuir-Blodgett (LB) films, induced by high energy ion irradiation, were examined by observation of ion induced emission and photoluminescence (PL). Various emission bands attributed to different defect sites in the band gap were observed at the initial irradiation stage. As the dose increased, the emissions via the trapping sites decreased in intensity while the band-edge emission developed. This suggests that the ion irradiation would remove almost all the trapping sites in the band gap. The low energy emissions, which show a multiexponential decay, were due to a donor-acceptor recombination between the deeply trapped carriers. It was found that the processes of formation, reaction, and stabilization of the trapping sites would predominantly occur under the photooxidizing conditions. (author)

  17. Fabrication of Pt nanoparticle incorporated polymer nanowires by high energy ion and electron beam irradiation

    Science.gov (United States)

    Tsukuda, Satoshi; Takahasi, Ryouta; Seki, Shu; Sugimoto, Masaki; Idesaki, Akira; Yoshikawa, Masahito; Tanaka, Shun-Ichiro

    2016-01-01

    Polyvinylpyrrolidone (PVP)-Pt nanoparticles (NPs) hybrid nanowires were fabricated by high energy ion beam irradiation to PVP thin films including H2PtCl6. Single ion hitting caused crosslinking reactions of PVP and reduction of Pt ions within local cylindrical area along an ion trajectory (ion track); therefore, the PVP nanowires including Pt NPs were formed and isolated on Si substrate after wet-development procedure. The number of Pt NPs was easily controlled by the mixed ratio of PVP and H2PtCl6. However, increasing the amount of H2PtCl6 led to decreasing the radial size and separation of the hybrid nanowires during the wet-development. Additional electron beam irradiation after ion beam improved separation of the nanowires and controlled radial sizes due to an increase in the density of crosslinking points inner the nanowires.

  18. Neutron-induced electronic failures around a high-energy linear accelerator.

    Science.gov (United States)

    Kry, Stephen F; Johnson, Jennifer L; White, R Allen; Howell, Rebecca M; Kudchadker, Rajat J; Gillin, Michael T

    2011-01-01

    After a new in-vault CT-on-rails system repeatedly malfunctioned following use of a high-energy radiotherapy beam, we investigated the presence and impact of neutron radiation on this electronic system, as well as neutron shielding options. We first determined the CT scanner's failure rate as a function of the number of 18 MV monitor units (MUs) delivered. We then re-examined the failure rate with both 2.7-cm-thick and 7.6-cm-thick borated polyethylene (BPE) covering the linac head for neutron shielding. To further examine shielding options, as well as to explore which neutrons were relevant to the scanner failure, Monte Carlo simulations were used to calculate the neutron fluence and spectrum in the bore of the CT scanner. Simulations included BPE covering the CT scanner itself as well as covering the linac head. We found that the CT scanner had a 57% chance of failure after the delivery of 200 MUs. While the addition of neutron shielding to the accelerator head reduced this risk of failure, the benefit was minimal and even 7.6 cm of BPE was still associated with a 29% chance of failure after the delivery of 200 MU. This shielding benefit was achieved regardless of whether the linac head or CT scanner was shielded. Additionally, it was determined that fast neutrons were primarily responsible for the electronic failures. As illustrated by the CT-on-rails system in the current study, physicists should be aware that electronic systems may be highly sensitive to neutron radiation. Medical physicists should therefore monitor electronic systems that have not been evaluated for potential neutron sensitivity. This is particularly relevant as electronics are increasingly common in the therapy vault and newer electronic systems may exhibit increased sensitivity.

  19. Modeling the high-energy electronic state manifold of adenine: Calibration for nonlinear electronic spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Nenov, Artur, E-mail: Artur.Nenov@unibo.it; Giussani, Angelo; Segarra-Martí, Javier; Jaiswal, Vishal K. [Dipartimento di Chimica “G. Ciamician,” Università di Bologna, Via Selmi 2, IT-40126 Bologna (Italy); Rivalta, Ivan [Université de Lyon, CNRS, Institut de Chimie de Lyon, École Normale Supérieure de Lyon, 46 Allée d’Italie, F-69364 Lyon Cedex 07 (France); Cerullo, Giulio [Dipartimento di Fisica, Politecnico di Milano, IFN-CNR, Piazza Leonardo Da Vinci 32, IT-20133 Milano (Italy); Mukamel, Shaul [Department of Chemistry, University of California, Irvine, California 92697-2025 (United States); Garavelli, Marco, E-mail: marco.garavelli@unibo.it, E-mail: marco.garavelli@ens-lyon.fr [Dipartimento di Chimica “G. Ciamician,” Università di Bologna, Via Selmi 2, IT-40126 Bologna (Italy); Université de Lyon, CNRS, Institut de Chimie de Lyon, École Normale Supérieure de Lyon, 46 Allée d’Italie, F-69364 Lyon Cedex 07 (France)

    2015-06-07

    Pump-probe electronic spectroscopy using femtosecond laser pulses has evolved into a standard tool for tracking ultrafast excited state dynamics. Its two-dimensional (2D) counterpart is becoming an increasingly available and promising technique for resolving many of the limitations of pump-probe caused by spectral congestion. The ability to simulate pump-probe and 2D spectra from ab initio computations would allow one to link mechanistic observables like molecular motions and the making/breaking of chemical bonds to experimental observables like excited state lifetimes and quantum yields. From a theoretical standpoint, the characterization of the electronic transitions in the visible (Vis)/ultraviolet (UV), which are excited via the interaction of a molecular system with the incoming pump/probe pulses, translates into the determination of a computationally challenging number of excited states (going over 100) even for small/medium sized systems. A protocol is therefore required to evaluate the fluctuations of spectral properties like transition energies and dipole moments as a function of the computational parameters and to estimate the effect of these fluctuations on the transient spectral appearance. In the present contribution such a protocol is presented within the framework of complete and restricted active space self-consistent field theory and its second-order perturbation theory extensions. The electronic excited states of adenine have been carefully characterized through a previously presented computational recipe [Nenov et al., Comput. Theor. Chem. 1040–1041, 295-303 (2014)]. A wise reduction of the level of theory has then been performed in order to obtain a computationally less demanding approach that is still able to reproduce the characteristic features of the reference data. Foreseeing the potentiality of 2D electronic spectroscopy to track polynucleotide ground and excited state dynamics, and in particular its expected ability to provide

  20. Progress in electronics and photonics with nanomaterials

    DEFF Research Database (Denmark)

    Mishra, Yogendra Kumar; Murugan, Arul; Kotakoski, Jani

    2017-01-01

    -property relationship to advanced applications. This editorial covers various aspects about nanomaterials, which will be useful/attractive for beginners in the field of nanotechnology as well as for experts and for industrialists looking forward to exploit them for real world applications.......Nanomaterials have been at the center of attraction for almost five decades as their contributions to different disciplines such as electronics, photonics and medicine are enormous. Various kinds of nanomaterials have been developed and are currently utilized in innumerable applications...

  1. Influence of high-energy electron irradiation on ultra-low-k characteristics and transistor performance

    Science.gov (United States)

    Steidel, Katja; Choi, Kang-Hoon; Freitag, Martin; Gutsch, Manuela; Hohle, Christoph; Seidel, Robert; Thrun, Xaver; Werner, Thomas

    2013-03-01

    While significant resources are invested in bringing EUV lithography to the market, multi electron beam direct patterning is still being considered as an alternative or complementary approach for patterning of advanced technology nodes. The possible introduction of direct write technology into an advanced process flow however may lead to new challenges. For example, the impact of high-energy electrons on dielectric materials and devices may lead to changes in the electrical parameters of the circuit compared to parts conventionally exposed by optical lithography. Furthermore, degradation of product reliability may occur. These questions have not yet been clarified in detail. For this study, pre-structured 300mm wafers with a 28nm BEOL stack were dry-exposed at various processing levels using a 50kV variable shaped e-beam direct writer. The electrical parameters of exposed structures were compared to non-exposed structures. The data of line resistance, capacitance, and line to line leakage were found to be within the typical distributions of the standard process. The dielectric breakdown voltages were also comparable between the splits, suggesting no dramatic TDDB performance degradation. With respect to high-k metal gate transistor parameters, a decrease in threshold voltage shift sensitivity was observed as well as a reduced sensitivity to hot carrier injection. More detailed investigations are needed to determine how these findings need to be considered and whether they represent a risk for the introduction of maskless lithography into the process flow of advanced technology nodes.

  2. A study of high field quantum electrodynamics in the collision of high energy electrons with a terawatt laser

    Energy Technology Data Exchange (ETDEWEB)

    Horton-Smith, G.A.

    1998-07-01

    An experiment is described which studied quantum electrodynamic interactions under conditions of extremely high fields, along with a review of the relevant theory. The high fields were created by an intense, tightly-focused pulse of laser light at green or infrared wavelengths, into which was sent an ultra-relativistic electron beam of 46.6-GeV energy. The relevant theory is that of an electron in an electromagnetic wave so intense that the electron's mass is effectively shifted by the transverse momentum imparted to it by the wave, and the electron encounters field strengths comparable to the Schwinger critical field strength of 511 kV per Compton wavelength. An electron in the intense wave may radiate a photon and balance 4-momentum by absorbing multiple photons from the laser, which can lead to real photons with energies above the kinematic limit for conventional Compton scattering. All particles have significant probability of scattering multiple times while in the focus of the laser, including the photons radiated by the electrons, which may convert into electron-positron pairs, again with absorption of multiple photons from the laser. This experiment was able to measure the rates and spectra of positrons, electrons, and photons emerging from the interaction region. Results from both experiment and theoretical simulations are presented and compared. The results from the electron and positron measurements are compatible with the accepted theory, within experimental uncertainties due mainly to the laser intensity measurement. The photon spectrum shows the correct shape, but the ratio of rates in the linear and two-absorbed-photon portions of the spectrum does not vary as expected with the laser intensity, suggesting a disagreement with the accepted theory, with a significance of roughly two standard deviations. A follow-up experiment would be in order.

  3. Advanced Photonic and Electronic Systems WILGA 2010

    CERN Document Server

    Romaniuk, R S

    2010-01-01

    SPIE – PSP WILGA Symposium gathers two times a year in January and in May new adepts of advanced photonic and electronic systems. The event is oriented on components and applications. WILGA Symposium on Photonics and Web Engineering is well known on the web for its devotion to “young research” promotion under the eminent sponsorship of international engineering associations like SPIE and IEEE and their Poland Sections or Counterparts. WILGA is supported by the most important national professional organizations like KEiT PAN and PSP-Photonics Society of Poland. The Symposium is organized since 1998 twice a year. It has gathered over 4000 young researchers and published over 2000 papers mainly internationally, including more than 900 in 10 published so far volumes of Proc. SPIE. This paper is a digest of WILGA Symposium Series and WILGA 2010 summary. Introductory part treats WILGA Photonics Applications characteristics over the period 1998-2010. Following part presents a short report on the XXVth and XXVI...

  4. Photon/Electron Benchmarks for Intercode Comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, Henry Grady III [Los Alamos National Laboratory; Sweezy, Jeremy Ed [Los Alamos National Laboratory; Lemaire, Sebastien [CEA/DIF (France); Caillaud, M. [CEA/DIF (France); Sauvestre, J. E. [CEA/DIF (France); Umbert, A. [CEA/DIF (France)

    2015-07-21

    The goal of this work was to improve accuracy and efficiency of two Monte-Carlo transport codes (MCNP and DIANE) with an emphasis on γ+electron physics. The approach involved intercode comparisons + measurements for gamma/e- energy deposition in a cylinder with a photon source and different materials (C, Pb) and the bombardment of 15-MeV electrons on thick targets (Al, Be, Pb). Comparisons of the codes DIANE and MCNP6 showed good agreement (differences < 3%) for gamma-electron energy deposition in a 2D cylinder, except for the first 0.1 μm of lead (difference < 10%). Comparisons with measurements showed generally good agreement, often better than 10%; best-performing codes/options are problem-dependent; and single-event discrepancies are in active use in reviewing electron elastic scattering.

  5. The ATLAS Electron and Photon Trigger

    CERN Document Server

    Jones, Samuel David; The ATLAS collaboration

    2017-01-01

    Electron and photon triggers covering transverse energies from 5 GeV to several TeV are essential for signal selection in a wide variety of ATLAS physics analyses to study Standard Model processes and to search for new phenomena. Final states including leptons and photons had, for example, an important role in the discovery and measurement of the Higgs boson. Dedicated triggers are also used to collect data for calibration, efficiency and fake rate measurements. The ATLAS trigger system is divided in a hardware-based Level-1 trigger and a software-based high-level trigger, both of which were upgraded during the LHC shutdown in preparation for Run-2 operation. To cope with the increasing luminosity and more challenging pile-up conditions at a center-of-mass energy of 13 TeV, the trigger selections at each level are optimized to control the rates and keep efficiencies high. To achieve this goal multivariate analysis techniques are used. The ATLAS electron and photon triggers and their performance with Run 2 dat...

  6. The ATLAS Electron and Photon Trigger

    CERN Document Server

    Jones, Samuel David; The ATLAS collaboration

    2018-01-01

    Electron and photon triggers covering transverse energies from 5 GeV to several TeV are essential for signal selection in a wide variety of ATLAS physics analyses to study Standard Model processes and to search for new phenomena. Final states including leptons and photons had, for example, an important role in the discovery and measurement of the Higgs boson. Dedicated triggers are also used to collect data for calibration, efficiency and fake rate measurements. The ATLAS trigger system is divided in a hardware-based Level-1 trigger and a software-based high-level trigger, both of which were upgraded during the LHC shutdown in preparation for Run-2 operation. To cope with the increasing luminosity and more challenging pile-up conditions at a center-of-mass energy of 13 TeV, the trigger selections at each level are optimized to control the rates and keep efficiencies high. To achieve this goal multivariate analysis techniques are used. The ATLAS electron and photon triggers and their performance with Run 2 dat...

  7. Collisions of electrons with hydrogen atoms I. Package outline and high energy code

    Science.gov (United States)

    Benda, Jakub; Houfek, Karel

    2014-11-01

    Being motivated by the applied researchers' persisting need for accurate scattering data for the collisions of electrons with hydrogen atoms, we developed a computer package-Hex-that is designed to provide trustworthy results for all basic discrete and continuous processes within non-relativistic framework. The package consists of several computational modules that implement different methods, valid for specific energy regimes. Results of the modules are kept in a common database in the unified form of low-level scattering data (partial-wave T-matrices) and accessed by an interface program which is able to produce various derived quantities like e.g. differential and integral cross sections. This article is the first one of a series of articles that are concerned with the implementation and testing of the modules. Here we give an overview of their structure and present (a) the command-line interface program hex-db that can be also easily compiled into a derived code or used as a backend for a web-page form and (b) simple illustrative module specialized for high energies, hex-dwba, that implements distorted and plane wave Born approximation.

  8. Charge deep-level transient spectroscopy study of high-energy-electron-beam-irradiated hydrogenated amorphous silicon

    NARCIS (Netherlands)

    Klaver, A.; Nádaždy, V.; Zeman, M.; Swaaiij, R.A.C.M.M.

    2006-01-01

    We present a study of changes in the defect density of states in hydrogenated amorphous silicon (a-Si:H) due to high-energy electron irradiation using charged deep-level transient spectroscopy. It was found that defect states near the conduction band were removed, while in other band gap regions the

  9. Photon-hadron discrimination with improved clustering for a preshower detector in high energy heavy ion experiments

    Energy Technology Data Exchange (ETDEWEB)

    Pal, Susanta Kumar, E-mail: sushant@vecc.gov.in [Variable Energy Cyclotron Centre, 1/AF Bidhan Nagar, Kolkata 700064 (India); Chattopadhyay, Subhasis; Viyogi, Y.P. [Variable Energy Cyclotron Centre, 1/AF Bidhan Nagar, Kolkata 700064 (India)

    2012-11-21

    The fuzzy c-mean clustering algorithm has been applied to the data set consisting of hits in a highly granular photon multiplicity detector installed in the ALICE experiment at the LHC. The clusters obtained using a modification of the algorithm based on the intensity of cells (called weighted fuzzy c-mean algorithm) are used as input in an artificial neural network formalism for photon-hadron discrimination. Results are discussed in terms of the photon reconstruction efficiency and the purity of photon sample and their centrality and pseudorapidity dependence at the LHC energy.

  10. Electron and photon identification in the D0 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Abazov, V. M.; Abbott, B.; Acharya, B. S.; Adams, M.; Adams, T.; Agnew, J. P.; Alexeev, G. D.; Alkhazov, G.; Alton, A.; Askew, A.; Atkins, S.; Augsten, K.; Avila, C.; Badaud, F.; Bagby, L.; Baldin, B.; Bandurin, D. V.; Banerjee, S.; Barberis, E.; Baringer, P.; Bartlett, J. F.; Bassler, U.; Bazterra, V.; Bean, A.; Begalli, M.; Bellantoni, L.; Beri, S. B.; Bernardi, G.; Bernhard, R.; Bertram, I.; Besançon, M.; Beuselinck, R.; Bhat, P. C.; Bhatia, S.; Bhatnagar, V.; Blazey, G.; Blessing, S.; Bloom, K.; Boehnlein, A.; Boline, D.; Boos, E. E.; Borissov, G.; Borysova, M.; Brandt, A.; Brandt, O.; Brock, R.; Bross, A.; Brown, D.; Bu, X. B.; Buehler, M.; Buescher, V.; Bunichev, V.; Burdin, S.; Buszello, C. P.; Camacho-Pérez, E.; Casey, B. C. K.; Castilla-Valdez, H.; Caughron, S.; Chakrabarti, S.; Chan, K. M.; Chandra, A.; Chapon, E.; Chen, G.; Cho, S. W.; Choi, S.; Choudhary, B.; Cihangir, S.; Claes, D.; Clutter, J.; Cooke, M.; Cooper, W. E.; Corcoran, M.; Couderc, F.; Cousinou, M. -C.; Cutts, D.; Das, A.; Davies, G.; de Jong, S. J.; De La Cruz-Burelo, E.; Déliot, F.; Demina, R.; Denisov, D.; Denisov, S. P.; Desai, S.; Deterre, C.; DeVaughan, K.; Diehl, H. T.; Diesburg, M.; Ding, P. F.; Dominguez, A.; Dubey, A.; Dudko, L. V.; Duperrina, A.; Dutt, S.; Eads, M.; Edmunds, D.; Ellison, J.; Elvira, V. D.; Enari, Y.; Evans, H.; Evdokimov, V. N.; Feng, L.; Ferbel, T.; Fiedler, F.; Filthaut, F.; Fisher, W.; Fisk, H. E.; Fortner, M.; Fox, H.; Fuess, S.; Garbincius, P. H.; Garcia-Bellido, A.; García-González, J. A.; Gavrilov, V.; Geng, W.; Gerber, C. E.; Gershtein, Y.; Ginther, G.; Golovanov, G.; Grannis, P. D.; Greder, S.; Greenlee, H.; Grenier, G.; Gris, Ph.; Grivaz, J. -F.; Grohsjean, A.; Grünendahl, S.; Grünewald, M. W.; Guillemin, T.; Gutierrez, G.; Gutierrez, P.; Haley, J.; Han, L.; Harder, K.; Harel, A.; Hauptman, J. M.; Hays, J.; Head, T.; Hebbeker, T.; Hedin, D.; Hegab, H.; Heinson, A. P.; Heintz, U.; Hensel, C.; Heredia-De La Cruz, I.; Herner, K.; Hesketh, G.; Hildreth, M. D.; Hirosky, R.; Hoang, T.; Hobbs, J. D.; Hoeneisen, B.; Hogan, J.; Hohlfeld, M.; Holzbauer, J. L.; Howley, I.; Hubacek, Z.; Hynek, V.; Iashvili, I.; Ilchenko, Y.; Illingworth, R.; Ito, A. S.; Jabeen, S.; Jaffré, M.; Jayasinghe, A.; Jeong, M. S.; Jesik, R.; Jiang, P.; Johns, K.; Johnson, E.; Johnson, M.; Jonckheere, A.; Jonsson, P.; Joshi, J.; Jung, A. W.; Juste, A.; Kajfasz, E.; Karmanov, D.; Katsanos, I.; Kehoe, R.; Kermiche, S.; Khalatyan, N.; Khanov, A.; Kharchilava, A.; Kharzheev, Y. N.; Kiselevich, I.; Kohli, J. M.; Kozelov, A. V.; Kraus, J.; Kumar, A.; Kupco, A.; Kurča, T.; Kuzmin, V. A.; Lammers, S.; Lebrun, P.; Lee, H. S.; Lee, S. W.; Lee, W. M.; Lei, X.; Lellouch, J.; Li, D.; Li, H.; Li, L.; Li, Q. Z.; Lim, J. K.; Lincoln, D.; Linnemann, J.; Lipaev, V. V.; Lipton, R.; Liu, H.; Liu, Y.; Lobodenko, A.; Lokajicek, M.; Lopes de Sa, R.; Luna-Garcia, R.; Lyon, A. L.; Maciel, A. K. A.; Madar, R.; Magaña-Villalba, R.; Malik, S.; Malyshev, V. L.; Mansour, J.; Martínez-Ortega, J.; McCarthy, R.; McGivern, C. L.; Meijer, M. M.; Melnitchouk, A.; Menezes, D.; Mercadante, P. G.; Merkin, M.; Meyer, A.; Meyer, J.; Miconi, F.; Mondal, N. K.; Mulhearn, M.; Nagy, E.; Narain, M.; Nayyar, R.; Neal, H. A.; Negret, J. P.; Neustroev, P.; Nguyen, H. T.; Nunnemann, T.; Orduna, J.; Osman, N.; Osta, J.; Pal, A.; Parashar, N.; Parihar, V.; Park, S. K.; Partridge, R.; Parua, N.; Patwa, A.; Penning, B.; Perfilov, M.; Peters, Y.; Petridis, K.; Petrillo, G.; Pétroff, P.; Pleier, M. -A.; Podstavkov, V. M.; Popov, A. V.; Prewitt, M.; Price, D.; Prokopenko, N.; Qian, J.; Quadt, A.; Quinn, B.; Raja, R.; Ratoff, P. N.; Razumov, I.; Ripp-Baudot, I.; Rizatdinova, F.; Rominsky, M.; Ross, A.; Royon, C.; Rubinov, P.; Ruchti, R.; Sajot, G.; Sánchez-Hernández, A.; Sanders, M. P.; Santos, A. S.; Savage, G.; Sawyer, L.; Scanlon, T.; Schamberger, R. D.; Scheglov, Y.; Schellman, H.; Schwanenberger, C.; Schwienhorst, R.; Sekaric, J.; Severini, H.; Shabalina, E.; Shary, V.; Shaw, S.; Shchukin, A. A.; Simak, V.; Skubic, P.; Slattery, P.; Smirnov, D.; Snow, G. R.; Snow, J.; Snyder, S.; Söldner-Rembold, S.; Sonnenschein, L.; Soustruznik, K.; Stark, J.; Stoyanova, D. A.; Strauss, M.; Suter, L.; Svoisky, P.; Titov, M.; Tokmenin, V. V.; Tsai, Y. -T.; Tsybychev, D.; Tuchming, B.; Tully, C.; Uvarov, L.; Uvarov, S.; Uzunyan, S.; Van Kooten, R.; van Leeuwen, W. M.; Varelas, N.; Varnes, E. W.; Vasilyev, I. A.; Verkheev, A. Y.; Vertogradov, L. S.; Verzocchi, M.; Vesterinen, M.; Vilanova, D.; Vokac, P.; Wahl, H. D.; Wang, M. H. L. S.; Warchol, J.; Watts, G.; Wayne, M.; Weichert, J.; Welty-Rieger, L.; Williams, M. R. J.; Wilson, G. W.; Wobisch, M.; Wood, D. R.; Wyatt, T. R.; Xie, Y.; Yamada, R.; Yang, S.; Yasuda, T.; Yatsunenko, Y. A.; Ye, W.; Ye, Z.; Yin, H.; Yip, K.; Youn, S. W.; Yu, J. M.; Zennamo, J.; Zhao, T. G.; Zhou, B.; Zhu, J.; Zielinski, M.; Zieminska, D.; Zivkovic, L.

    2014-06-01

    The electron and photon reconstruction and identification algorithms used by the D0 Collaboration at the Fermilab Tevatron collider are described. The determination of the electron energy scale and resolution is presented. Studies of the performance of the electron and photon reconstruction and identification are summarized.

  11. Atomic data for integrated tokamak modelling – Fermi-shuttle type ionization as a possible source of high energy electrons

    Directory of Open Access Journals (Sweden)

    Tőkési K.

    2014-01-01

    Full Text Available The ionization of Ar by 15 keV N+ ion is studied theoretically. The energy distributions of the ejected electrons as a function of the scattering angle were calculated using the classical trajectory Monte Carlo method. We identify the signature of the Fermi-shuttle type ionization in the double differential cross sections which should be a possible source of the high energy electrons in the plasma. Our classical calculation also describes the previously measured data with high accuracy.

  12. High energy resolution and first time-dependent positron annihilation induced Auger electron spectroscopty

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, Jakob

    2010-04-03

    . Secondly, the short recording time enabled for the first time the measurement of dynamic processes with PAES. Finally, the unprecedented high energy resolution allowed for the first time the observation of the double peak structure of the CuM{sub 2,3}VV-transition with PAES. Thus, within this thesis two objectives were achieved: Firstly, the PAES spectrometer was renewed and improved by at least one order of magnitude with respect to the signal to noise ratio, the measurement time and the energy resolution. Secondly, several measurements have been carried out, demonstrating the high performance of the spectrometer. Amongst them are first dynamic PAES measurements and a high resolution measurement of the CuM{sub 2,3}VV-transition. (orig.)

  13. Calculation of Nuclear Particles Production at High-Energy Photon Beams from a Linac Operating at 6, 10 and 15 MV.

    Science.gov (United States)

    Marchesini, Renato; Bettega, Daniela; Calzolari, Paola; Pignoli, Emanuele

    2017-05-01

    Production of photonuclear particles in a tissue-equivalent medium has been calculated for linacs at 6, 10 and 15 MV from Varian TrueBeam. Based on the knowledge of bremsstrahlung fluence spectra and linac photon beam parameters, numerical integration was performed on the cross sections for photoparticle production of the constituent elements of tissue (2H,12C,13C,16O,17O,18O,14N,15N). At 15 MV, at the depth of photon maximum dose, the total absorbed dose due to neutrons, protons, alphas and residual nuclei from photon reactions in tissue (5.5E-05 Gy per Gy of photons) is comparable to that due to neutrons from accelerator head. Results reasonably agree with data reported in the literature using Monte Carlo models simulating linac head components. This work suggests a simple method to estimate the dose contributed by the photon-induced nuclear particles for high-energy photon beams produced by linacs in use, as it might be relevant for late stochastic effects. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Present trends and realisations in readout electronics for semiconductor detectors in high energy physics

    Energy Technology Data Exchange (ETDEWEB)

    Gatti, E. (Politecnico di Milano (Italy). Ist. di Fisica); Manfredi, P.F. (Pavia Univ. (Italy). Ist. di Elettronica; Istituto Nazionale di Fisica Nucleare, Milan (Italy))

    1984-09-15

    Design criteria of signal processors for semiconductor detectors in high energy physics experiments are reviewed. Choice of input active devices of preamplifiers, detector-device capacitive matching, preamplifier configurations, variant and invariant signal processors are discussed. Several examples of processors for microstrip silicon detectors and for silicon detector telescopes are reviewed with particular emphasis on noise performance and high rate capabilities.

  15. Photon-photon colliders

    Energy Technology Data Exchange (ETDEWEB)

    Sessler, A.M.

    1995-04-01

    Since the seminal work by Ginsburg, et at., the subject of giving the Next Linear Collider photon-photon capability, as well as electron-positron capability, has drawn much attention. A 1990 article by V.I. Teinov describes the situation at that time. In March 1994, the first workshop on this subject was held. This report briefly reviews the physics that can be achieved through the photon-photon channel and then focuses on the means of achieving such a collider. Also reviewed is the spectrum of backscattered Compton photons -- the best way of obtaining photons. We emphasize the spectrum actually obtained in a collider with both polarized electrons and photons (peaked at high energy and very different from a Compton spectrum). Luminosity is estimated for the presently considered colliders, and interaction and conversion-point geometries are described. Also specified are laser requirements (such as wavelength, peak power, and average power) and the lasers that might be employed. These include conventional and free-electron lasers. Finally, we describe the R&D necessary to make either of these approaches viable and explore the use of the SLC as a test bed for a photon-photon collider of very high energy.

  16. Progress in electronics and photonics with nanomaterials

    DEFF Research Database (Denmark)

    Mishra, Yogendra Kumar; Murugan, Arul; Kotakoski, Jani

    2017-01-01

    Nanomaterials have been at the center of attraction for almost five decades as their contributions to different disciplines such as electronics, photonics and medicine are enormous. Various kinds of nanomaterials have been developed and are currently utilized in innumerable applications....... Nevertheless, their simple realization and easy and efficient upscaling are topics under intense investigation. Innovative strategies have been adopted for nanomaterial synthesis and their usability. Here, we provide a brief overview on nanomaterials ranging from basic understanding of their structure......-property relationship to advanced applications. This editorial covers various aspects about nanomaterials, which will be useful/attractive for beginners in the field of nanotechnology as well as for experts and for industrialists looking forward to exploit them for real world applications....

  17. A novel nuclear pyrometry for the characterization of high-energy bremsstrahlung and electrons produced in relativistic laser-plasma interactions

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, M. M.; Sonnabend, K.; Harres, K.; Roth, M. [Institut fuer Kernphysik, Schlossgartenstr. 9, Technische Universitaet Darmstadt, D-64289 Darmstadt (Germany); Brambrink, E. [Laboratoire pour l' Utilisation des Lasers Intenses, UMR 7605 CNRS-CEA-Ecole Polytechnique-Universite Paris VI, F-91128 Palaiseau (France); Vogt, K.; Bagnoud, V. [GSI - Helmholtzzentrum fuer Schwerionenforschung GmbH, Planckstr. 1, D-64291 Darmstadt (Germany)

    2011-08-15

    We present a novel nuclear activation-based method for the investigation of high-energy bremsstrahlung produced by electrons above 7 MeV generated by a high-power laser. The main component is a novel high-density activation target that is a pseudo alloy of several selected isotopes with different photo-disintegration reaction thresholds. The gamma spectrum emitted by the activated targets is used for the reconstruction of the bremsstrahlung spectrum using an analysis method based on Penfold and Leiss. This nuclear activation-based technique allows for the determination of the number of bremsstrahlung photons per energy bin in a wide range energy without any anticipated fit procedures. Furthermore, the analysis method also allows for the determination of the absolute yield, the energy distribution, and the temperature of high-energy electrons at the relativistic laser-plasma interaction region. The pyrometry is sensitive to energies above 7 MeV only, i.e., this diagnostic is insensitive to any low-energy processes.

  18. Reflection High-Energy Electron Diffraction Beam-Induced Structural and Property Changes on WO3 Thin Films

    Energy Technology Data Exchange (ETDEWEB)

    Du, Yingge; Zhang, Hongliang; Varga, Tamas; Chambers, Scott A.

    2014-08-08

    Reduction of transition metal oxides can greatly change their physical and chemical properties. Using deposition of WO3 as a case study, we demonstrate that reflection high-energy electron diffraction (RHEED), a surface-sensitive tool widely used to monitor thin-film deposition processes, can significantly affect the cation valence and physical properties of the films through electron-beam induced sample reduction. The RHEED beam is found to increase film smoothness during epitaxial growth of WO3, as well as change the electronic properties of the film through preferential removal of surface oxygen.

  19. Electron and photon emissions from gold nanoparticles irradiated by X-ray photons

    Energy Technology Data Exchange (ETDEWEB)

    Casta, R., E-mail: castaromain@gmail.com, E-mail: romain.casta@irsamc.ups-tlse.fr; Champeaux, J.-P.; Moretto-Capelle, P.; Sence, M.; Cafarelli, P. [Université de Toulouse, UPS, Laboratoire Collisions Agrégats Réactivité, IRSAMC, CNRS, UMR 5589 (France)

    2015-01-15

    In this paper, we develop a totally new probabilistic model for the electron and photon emission of gold nanoparticles irradiated by X-ray photons. This model allows direct applications to recent researches about the radiotherapy enhancement by gold nanoparticles in the context of cancer treatment. Our model uses, in a complete original way, simulated Auger cascade and stopping power to compute electron emission spectra, photon emission spectra and released energy inside the material of gold nanoparticles. It allows us to present new results about the electron and photon emission of gold nanoparticle irradiated by hard X-rays.

  20. Development of an air-stable, high energy density printed silver oxide battery for printed electronics

    OpenAIRE

    Braam, Kyle

    2014-01-01

    Printed batteries are an emerging battery technology that has the potential to enable the production of cheap, small form factor, flexible batteries capable of powering a diverse set of existing and emerging applications such as RFID tags, flexible displays, and distributed sensors. Partially printed battery systems have been demonstrated with various chemistries, but what is needed is a low cost, air stable method of fully printing a high energy density battery. The silver oxide chemistry i...

  1. Self-assembled Nanomaterials for Hybrid Electronic and Photonic Systems

    Science.gov (United States)

    2015-05-15

    Self-assembled Nanomaterials for Hybrid Electronic and Photonic Systems This grant studied DNA nanostructures and their applications in a variety of...Number of Papers published in non peer-reviewed journals: Final Report: Self-assembled Nanomaterials for Hybrid Electronic and Photonic Systems Report

  2. High energy micro electron beam generation using chirped laser pulse in the presence of an axial magnetic field

    Science.gov (United States)

    Akou, H.; Hamedi, M.

    2015-10-01

    In this paper, the generation of high-quality and high-energy micro electron beam in vacuum by a chirped Gaussian laser pulse in the presence of an axial magnetic field is numerically investigated. The features of energy and angular spectra, emittances, and position distribution of electron beam are compared in two cases, i.e., in the presence and absence of an external magnetic field. The electron beam is accelerated with higher energy and qualified in spatial distribution in the presence of the magnetic field. The presence of an axial magnetic field improves electron beam spatial quality as well as its gained energy through keeping the electron motion parallel to the direction of propagation for longer distances. It has been found that a 64 μm electron bunch with about MeV initial energy becomes a 20 μm electron beam with high energy of the order of GeV, after interacting with a laser pulse in the presence of an external magnetic field.

  3. High energy micro electron beam generation using chirped laser pulse in the presence of an axial magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Akou, H., E-mail: h.akou@nit.ac.ir; Hamedi, M. [Department of Physics, Faculty of Basic Science, Babol University of Technology, Babol 47148-71167 (Iran, Islamic Republic of)

    2015-10-15

    In this paper, the generation of high-quality and high-energy micro electron beam in vacuum by a chirped Gaussian laser pulse in the presence of an axial magnetic field is numerically investigated. The features of energy and angular spectra, emittances, and position distribution of electron beam are compared in two cases, i.e., in the presence and absence of an external magnetic field. The electron beam is accelerated with higher energy and qualified in spatial distribution in the presence of the magnetic field. The presence of an axial magnetic field improves electron beam spatial quality as well as its gained energy through keeping the electron motion parallel to the direction of propagation for longer distances. It has been found that a 64 μm electron bunch with about MeV initial energy becomes a 20 μm electron beam with high energy of the order of GeV, after interacting with a laser pulse in the presence of an external magnetic field.

  4. Influence of high-energy electron irradiation on field emission properties of multi-walled carbon nanotubes (MWCNTs) films

    Energy Technology Data Exchange (ETDEWEB)

    Patil, Sandip S. [Center for Advanced Studies in Material Science and Condensed Matter Physics, Department of Physics, University of Pune, Pune 411007 (India); Koinkar, Pankaj M. [Center for International Cooperation in Engineering Education (CICEE), University of Tokushima, 2-1 Minami-Josanjima-Cho, Tokushima 770-8506 (Japan); Dhole, Sanjay D. [Center for Advanced Studies in Material Science and Condensed Matter Physics, Department of Physics, University of Pune, Pune 411007 (India); More, Mahendra A., E-mail: mam@physics.unipune.ac.i [Center for Advanced Studies in Material Science and Condensed Matter Physics, Department of Physics, University of Pune, Pune 411007 (India); Murakami, Ri-ichi, E-mail: murakami@me.tokushima-u.ac.j [Department of Mechanical Engineering, University of Tokushima, 2-1 Minami-Josanjima-Cho, Tokushima 770-8506 (Japan)

    2011-04-15

    The effect of very high energy electron beam irradiation on the field emission characteristics of multi-walled carbon nanotubes (MWCNTs) has been investigated. The MWCNTs films deposited on silicon (Si) substrates were irradiated with 6 MeV electron beam at different fluence of 1x10{sup 15}, 2x10{sup 15} and 3x10{sup 15} electrons/cm{sup 2}. The irradiated films were characterized using scanning electron microscope (SEM) and micro-Raman spectrometer. The SEM analysis clearly revealed a change in surface morphology of the films upon irradiation. The Raman spectra of the irradiated films show structural damage caused by the interaction of high-energy electrons. The field emission studies were carried out in a planar diode configuration at the base pressure of {approx}1x10{sup -8} mbar. The values of the threshold field, required to draw an emission current density of {approx}1 {mu}A/cm{sup 2}, are found to be {approx}0.52, 1.9, 1.3 and 0.8 V/{mu}m for untreated, irradiated with fluence of 1x10{sup 15}, 2x10{sup 15} and 3x10{sup 15} electrons/cm{sup 2}. The irradiated films exhibit better emission current stability as compared to the untreated film. The improved field emission properties of the irradiated films have been attributed to the structural damage as revealed from the Raman studies.

  5. Experience with high-energy electron beam therapy at the University of Chicago

    Energy Technology Data Exchange (ETDEWEB)

    Griem, M L; Kuchnir, F T; Lanzl, L H; Skaggs, L S; Sutton, H G; Tokars, R

    1979-01-01

    Current utilization of the linear accelerator as well as 5-year cumulative experience in radiotherapy is presented. Cutaneous lymphomas and mammary gland carcinomas were the prime experience region; however, cancers at other locations were treated with mixed-beam therapy; employing fast neutrons and photon beams. The technique appears promising for abdominal tumors and deep-seated malignancies. Carcinoma of the pancreas responds favorably to this technique. (PCS)

  6. Diffracted transition radiation of an ultra-high-energy relativistic electron beam in a thin single-crystal wafer

    Energy Technology Data Exchange (ETDEWEB)

    Blazhevich, S. V.; Noskov, A. V., E-mail: noskovbupk@mail.ru [Belgorod State University (Russian Federation)

    2016-10-15

    We consider diffracted transition radiation (DTR) emitted by high-energy relativistic electrons crossing a thin single-crystal wafer in the Laue geometry. The expression describing the DTR angular density is derived for the case where the electron path length in the target is much smaller than the X-ray wave extinction length in the crystal and the kinematic nature of this expression is demonstrated. It is shown that the DTR angular density in a thin target is proportional to the target thickness.

  7. Are neutrons responsible for the dose discrepancies between Monte Carlo calculations and measurements in the build-up region for a high-energy photon beam?

    Energy Technology Data Exchange (ETDEWEB)

    Ding, George X. [Medical Physics, Fraser Valley Cancer Centre, British Columbia Cancer Agency, Surrey, BC (Canada)]. E-mail: gding@bccancer.bc.ca; Duzenli, Cheryl; Kalach, Nina I. [Medical Physics, Fraser Valley Cancer Centre, British Columbia Cancer Agency, Surrey, BC (Canada)

    2002-09-07

    This study presents measured neutron dose using a neutron dosimeter in a water phantom and investigates a hypothesis that neutrons in a high-energy photon beam may be responsible for the reported significant dose discrepancies between Monte Carlo calculations and measurements at the build-up region in large fields. Borated polyethylene slabs were inserted between the accelerator head and the phantom in order to remove neutrons generated in the accelerator head. The thickness of the slab ranged from 2.5 cm to 10 cm. A lead slab of 3 mm thickness was also used in the study. The superheated drop neutron dosimeter was used to measure the depth-dose curve of neutrons in a high-energy photon beam and to verify the effectiveness of the slab to remove these neutrons. Total dose measurements were performed in water using a WELLHOFER WP700 beam scanner with an IC-10 ionization chamber. The Monte Carlo code BEAM was used to simulate an 18 MV photon beam from a Varian Clinac-2100EX accelerator. Both EGS4/DOSXYZ and EGSnrc/DOSRZnrc were used in the dose calculations. Measured neutron dose equivalents as a function of depth per unit total dose in water were presented for 10x10 and 40x40 cm{sup 2} fields. The measured results have shown that a 5-10 cm thick borated polyethylene slab can reduce the neutron dose by a factor of 2 when inserted between the accelerator head and the detector. In all cases the measured neutron dose equivalent was less than 0.5% of the photon dose. In order to study if the ion chamber was highly sensitive to the neutron dose, we have investigated the disagreement between the Monte Carlo calculated and measured central-axis depth-dose curves in the build-up region when different shielding materials were used. The result indicated that the IC-10 chamber was not highly sensitive to the neutron dose. Therefore, neutrons present in a high-energy photon beam were unlikely to be responsible for the reported discrepancies in the build-up region for large fields

  8. Are neutrons responsible for the dose discrepancies between Monte Carlo calculations and measurements in the build-up region for a high-energy photon beam?

    Science.gov (United States)

    Ding, George X; Duzenli, Cheryl; Kalach, Nina I

    2002-09-07

    This study presents measured neutron dose using a neutron dosimeter in a water phantom and investigates a hypothesis that neutrons in a high-energy photon beam may be responsible for the reported significant dose discrepancies between Monte Carlo calculations and measurements at the build-up region in large fields. Borated polyethylene slabs were inserted between the accelerator head and the phantom in order to remove neutrons generated in the accelerator head. The thickness of the slab ranged from 2.5 cm to 10 cm. A lead slab of 3 mm thickness was also used in the study. The superheated drop neutron dosimeter was used to measure the depth-dose curve of neutrons in a high-energy photon beam and to verify the effectiveness of the slab to remove these neutrons. Total dose measurements were performed in water using a WELLHOFER WP700 beam scanner with an IC-10 ionization chamber. The Monte Carlo code BEAM was used to simulate an 18 MV photon beam from a Varian Clinac-2100EX accelerator. Both EGS4/DOSXYZ and EGSnrc/DOSRZnrc were used in the dose calculations. Measured neutron dose equivalents as a function of depth per unit total dose in water were presented for 10 x 10 and 40 x 40 cm2 fields. The measured results have shown that a 5-10 cm thick borated polyethylene slab can reduce the neutron dose by a factor of 2 when inserted between the accelerator head and the detector. In all cases the measured neutron dose equivalent was less than 0.5% of the photon dose. In order to study if the ion chamber was highly sensitive to the neutron dose, we have investigated the disagreement between the Monte Carlo calculated and measured central-axis depth-dose curves in the build-up region when different shielding materials were used. The result indicated that the IC-10 chamber was not highly sensitive to the neutron dose. Therefore, neutrons present in a high-energy photon beam were unlikely to be responsible for the reported discrepancies in the build-up region for large fields.

  9. Electron transport through a quantum dot assisted by cavity photons

    Science.gov (United States)

    Abdullah, Nzar Rauf; Tang, Chi-Shung; Manolescu, Andrei; Gudmundsson, Vidar

    2013-11-01

    We investigate transient transport of electrons through a single quantum dot controlled by a plunger gate. The dot is embedded in a finite wire with length Lx assumed to lie along the x-direction with a parabolic confinement in the y-direction. The quantum wire, originally with hard-wall confinement at its ends, ±Lx/2, is weakly coupled at t = 0 to left and right leads acting as external electron reservoirs. The central system, the dot and the finite wire, is strongly coupled to a single cavity photon mode. A non-Markovian density-matrix formalism is employed to take into account the full electron-photon interaction in the transient regime. In the absence of a photon cavity, a resonant current peak can be found by tuning the plunger-gate voltage to lift a many-body state of the system into the source-drain bias window. In the presence of an x-polarized photon field, additional side peaks can be found due to photon-assisted transport. By appropriately tuning the plunger-gate voltage, the electrons in the left lead are allowed to undergo coherent inelastic scattering to a two-photon state above the bias window if initially one photon was present in the cavity. However, this photon-assisted feature is suppressed in the case of a y-polarized photon field due to the anisotropy of our system caused by its geometry.

  10. Electron and Photon Reconstruction and Identification with the ATLAS Detector

    CERN Document Server

    Turlay, E

    2008-01-01

    The status of the reconstruction and identification of electrons and photons in the ATLAS detector is presented. Electrons and photons are crucial for both a thorough understanding of the detector and physics studies. An electrons identification efficiency of 64% can be reached for a jet rejection of 10^5. The electromagnetic energy scale can be estimated with a permil accuracy. The reconstruction process is described along with the identification and calibration techniques developed to obtain the required performance.

  11. ELEC-2005 - Electronics in High Energy Physics: Autumn Term (November-December 2005)

    CERN Multimedia

    Davide Vitè

    2005-01-01

    ELEC-2005 is a new course series on modern electronics, given by CERN physicists and engineers within the framework of the 2005 Technical Training Programme, in an extended format of the ELEC-2002 course series. This new, comprehensive course series is designed for people who are not electronics specialists, for example physicists, engineers and technicians working at or visiting the laboratory, who use or will use electronics in their present or future activities, in particular in the context of the LHC accelerator and experiments. ELEC-2005 is composed of four Terms. The Winter (Introduction to electronics in HEP), Spring (Integrated circuits and VLSI technology for physics), and Summer (System electronics for physics: Issues) Terms already took place. The Autumn Term - Electronics applications in HEP experiments (November-December, 10 lectures) is still open for registration, and has started on November 8th with the following programme: Tuesday 8.11 - Tracking (Geoff Hall). Thursday 10.11 - Calorimetr...

  12. CERN Technical Training 2005 - ELEC-2005: Electronics in High Energy Physics

    CERN Multimedia

    Monique Duval

    2004-01-01

    Learning for the LHC!ELEC-2005 is a new course series on modern electronics, given by CERN physicists and engineers within the framework of the 2005 Technical Training Programme, in an extended format of the successful ELEC-2002 course series. This comprehensive course series is designed for people who are not electronics specialists, for example physicists, engineers and technicians working at or visiting the laboratory, who use or will use electronics in their present or future activities, in particular in the context of the LHC accelerator and experiments.ELEC-2005 is composed of four Terms that will run throughout the year:Winter Term: Introduction to electronics in HEP (January-February, 6 lectures) Spring Term: Integrated circuits and VLSI technology for physics (March, 6 lectures) Summer Term: System electronics for physics: Issues (May, 7 lectures) Winter Term: Electronics applications in HEP experiments (November-December, 10 lectures) Lectures within each Term will take place on Tuesdays and Thursd...

  13. Technical Training: ELEC-2005 - Electronics in High Energy Physics: Summer Term (May 2005)

    CERN Multimedia

    Monique Duval

    2005-01-01

    ELEC-2005 is a new course series on modern electronics, given by CERN physicists and engineers within the framework of the 2005 Technical Training Programme, in an extended format of the successful ELEC-2002 course series. This comprehensive course series is designed for people who are not electronics specialists, for example physicists, engineers and technicians working at or visiting the laboratory, who use or will use electronics in their present or future activities, in particular in the context of the LHC accelerator and experiments. ELEC-2005 is composed of four Terms. The Winter (Introduction to electronics in HEP) and Spring (Integrated circuits and VLSI technology for physics) Terms already took place; the next two Terms will run with the following schedule: Summer Term: System electronics for physics: Issues (May, 7 lectures) - now open for registration Autumn Term: Electronics applications in HEP experiments (November-December, 10 lectures) Lectures within each Term will take place on Tuesday...

  14. Simulation of high-energy radiation belt electron fluxes using NARMAX-VERB coupled codes

    OpenAIRE

    I. P. Pakhotin; A. Y. Drozdov; Yuri Shprits; R. J. Boynton; D. A. Subbotin; M. A. Balikhin

    2014-01-01

    This study presents a fusion of data-driven and physics-driven methodologies of energetic electron flux forecasting in the outer radiation belt. Data-driven NARMAX (Nonlinear AutoRegressive Moving Averages with eXogenous inputs) model predictions for geosynchronous orbit fluxes have been used as an outer boundary condition to drive the physics-based Versatile Electron Radiation Belt (VERB) code, to simulate energetic electron fluxes in the outer radiation belt environment. The coupled system ...

  15. Non-reference condition correction factor kNR of typical radiation detectors applied for the dosimetry of high-energy photon fields in radiotherapy.

    Science.gov (United States)

    Chofor, Ndimofor; Harder, Dietrich; Poppe, Björn

    2012-09-01

    According to accepted dosimetry protocols, the "radiation quality correction factor"k(Q) accounts for the energy-dependent changes of detector responses under the conditions of clinical dosimetry for high-energy photon radiations. More precisely, a factor k(QR) is valid under reference conditions, i.e. at a point on the beam axis at depth 10 cm in a large water phantom, for 10×10 cm(2) field size, SSD 100 cm and the given radiation quality with quality index Q. Therefore, a further correction factor k(NR) has been introduced to correct for the influences of spectral quality changes when detectors are used under non-reference conditions such as other depths, field sizes and off-axis distances, while under reference conditions k(NR) is normalized to unity. In this paper, values of k(NR) are calculated for 6 and 15 MV photon beams, using published data of the energy-dependent responses of various radiation detectors to monoenergetic photon radiations, and weighting these responses with validated photon spectra of clinical high-energy photon beams from own Monte-Carlo-calculations for a wide variation of the non-reference conditions within a large water phantom. Our results confirm the observation by Scarboro et al. [26] that k(NR) can be represented by a unique function of the mean energy Em, weighted by the spectral photon fluence. Accordingly, the numerical variations of Em with depth, field size and off-axis distance have been provided. Throughout all considered conditions, the deviations of the k(NR) values from unity are at most 2% for a Farmer type ion chamber, and they remain below 15% for the thermoluminescent detectors LiF:Mg,Ti and LiF:Mg,Cu,P. For the shielded diode EDP-10, k(NR) varies from unity up to 20%, while the unshielded diode EDD-5 shows deviations up to 60% in the peripheral region. Thereby, the restricted application field of unshielded diodes has been clarified. For small field dosimetry purposes k(NR) can be converted into k(NCSF), the non

  16. Non-reference condition correction factor k{sub NR} of typical radiation detectors applied for the dosimetry of high-energy photon fields in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chofor, Ndimofor; Poppe, Bjoern [Oldenburg Univ. (Germany). Working Group Medical Radiation Physics; Pius Hospital, Oldenburg (Germany). Clinic of Radiotherapy and Oncology; Harder, Dietrich

    2012-11-01

    According to accepted dosimetry protocols, the 'radiation quality correction factor' k{sub Q} accounts for the energy-dependent changes of detector responses under the conditions of clinical dosimetry for high-energy photon radiations. More precisely, a factor k{sub QR} is valid under reference conditions, i.e. at a point on the beam axis at depth 10 cm in a large water phantom, for 10 x 10 cm{sup 2} field size, SSD 100 cm and the given radiation quality with quality index Q. Therefore, a further correction factor k{sub NR} has been introduced to correct for the influences of spectral quality changes when detectors are used under non-reference conditions such as other depths, field sizes and off-axis distances, while under reference conditions k{sub NR} is normalized to unity. In this paper, values of k{sub NR} are calculated for 6 and 15 MV photon beams, using published data of the energy-dependent responses of various radiation detectors to monoenergetic photon radiations, and weighting these responses with validated photon spectra of clinical high-energy photon beams from own Monte-Carlo-calculations for a wide variation of the non-reference conditions within a large water phantom. Our results confirm the observation by Scarboro et al. [26] that k{sub NR} can be represented by a unique function of the mean energy Em, weighted by the spectral photon fluence. Accordingly, the numerical variations of Em with depth, field size and off-axis distance have been provided. Throughout all considered conditions, the deviations of the k{sub NR} values from unity are at most 2% for a Farmer type ion chamber, and they remain below 15% for the thermoluminescent detectors LiF:Mg,Ti and LiF:Mg,Cu,P. For the shielded diode EDP-10, k{sub NR} varies from unity up to 20%, while the unshielded diode EDD-5 shows deviations up to 60% in the peripheral region. Thereby, the restricted application field of unshielded diodes has been clarified. For small field dosimetry purposes

  17. High energy electron beams from a laser wakefield acceleration with a long gas jet

    Science.gov (United States)

    Kim, Jaehoon; Hwangbo, Yong Hun; Lee, Shin-Yeong

    2017-09-01

    A long gas jet was used as a gas target for laser wake field acceleration to increase the energy and quality of the electron beam. When the plasma density was 7 × 1018 cm-3, quasi monoenergetic electron beams with a maximum energy of 152 MeV, a beam divergence 3 mrad, and a pointing stability 4 mrad were generated with a 5 mm long gas jet. The maximum energy was close to the theoretical limit predicted from the bubble model. This means that the length of the plasma was sufficiently long to accelerate the electron to the dephasing length after the electrons were self-injected by self-focusing. As the plasma density increased, the dephasing length decreased and the electron energy decreased. The continuous injection with higher density plasmas generated highly diverging beams. As the laser power increased, a number of electron beams with different propagation directions were generated. As shown by the measured shadowgram, the laser was divided into several filaments and each filament accelerated electron beam having different directions. The electron beam generated at this time decreased as the laser energy decreased due the division of the laser into different directions.

  18. Total and elastic electron scattering cross sections from Xe at intermediate and high energies

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, G [Instituto de Matematicas y Fisica Fundamental, CSIC, Serrano 123, 28006 Madrid (Spain); Pablos, J L de [Departamento de Fusion y Particulas Elementales, CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain); Blanco, F [Departamento de Fisica Atomica Molecular y Nuclear, Universidad Complutense de Madrid, 28040 Madrid (Spain); Williart, A [Departamento de Fisica de los Materiales, UNED, Senda del Rey 9, 28040 Madrid (Spain)

    2002-11-28

    Experimental total electron scattering cross sections from Xe in the energy range 300-5000 eV have been obtained with experimental errors of about 3%. The method was based on the measurement of the attenuation of a linear electron beam through a Xe gas cell in combination with an electron spectroscopy technique to analyse the energy of the transmitted electrons. Differential and integral elastic cross sections have been calculated using a scattering potential method which includes relativistic effects. The consistency of our theoretical and experimental results is also discussed in the paper. Finally, analytical formulae depending on two parameters, namely the number of target electrons and the atomic polarizability, are given to reproduce the experimental data for Ne, Ar, Kr and Xe in the energy range 500-10 000 eV.

  19. Technical Training: ELEC-2005 - Electronics in High Energy Physics: Summer Term (May 2005)

    CERN Multimedia

    Davide Vitè

    2005-01-01

    ELEC-2005 is a new course series on modern electronics, given by CERN physicists and engineers within the framework of the 2005 Technical Training Programme, in an extended format of the successful ELEC-2002 course series.This comprehensive course series is designed for people who are not electronics specialists, for example physicists, engineers and technicians working at or visiting the laboratory, who use or will use electronics in their present or future activities, in particular in the context of the LHC accelerator and experiments. ELEC-2005 is composed of four Terms. The last two Terms will run with the following schedule: Summer Term: System electronics for physics: Issues (May, 7 lectures) - now open for registration Autumn Term: Electronics applications in HEP experiments (November-December, 10 lectures) Lectures within each Term will take place on Tuesdays and Thursdays, from 10h00 to 12h30. The course will be in English, with questions and answers also possible in French. Separate registrati...

  20. Influence of the Integral Quality Monitor transmission detector on high energy photon beams. A multi-centre study

    Energy Technology Data Exchange (ETDEWEB)

    Casar, Bozidar [Institute of Oncology, Ljubljana (Slovenia). Dept. of Radiation Physics; Pasler, Marlies [Lake Constance Radiation Oncology Center, Singen and Friedrichshafen (Germany); Wegener, Sonja [Wuerzburg Univ. (Germany). Dept. of Radiation Oncology; and others

    2017-10-01

    The influence of the Integral Quality Monitor (IQM) transmission detector on photon beam properties was evaluated in a preclinical phase, using data from nine participating centres: (i) the change of beam quality (beam hardening), (ii) the influence on surface dose, and (iii) the attenuation of the IQM detector. For 6 different nominal photon energies (4 standard, 2 FFF) and square field sizes from 1 x 1 cm{sup 2} to 20 x 20 cm{sup 2}, the effect of IQM on beam quality was assessed from the PDD{sub 20,10} values obtained from the percentage dose depth (PDD) curves, measured with and without IQM in the beam path. The change in surface dose with/without IQM was assessed for all available energies and field sizes from 4 x 4 cm{sup 2} to 20 x 20 cm{sup 2}. The transmission factor was calculated by means of measured absorbed dose at 10 cm depth for all available energies and field sizes. (i) A small (0.11-0.53%) yet statistically significant beam hardening effect was observed, depending on photon beam energy. (ii) The increase in surface dose correlated with field size (p < 0.01) for all photon energies except for 18 MV. The change in surface dose was smaller than 3.3% in all cases except for the 20 x 20 cm{sup 2} field and 10 MV FFF beam, where it reached 8.1%. (iii) For standard beams, transmission of the IQM showed a weak dependence on the field size, and a pronounced dependence on the beam energy (0.9412 for 6 MV to 0.9578 for 18 MV and 0.9440 for 6 MV FFF; 0.9533 for 10 MV FFF). The effects of the IQM detector on photon beam properties were found to be small yet statistically significant. The magnitudes of changes which were found justify treating IQM either as tray factors within the treatment planning system (TPS) for a particular energy or alternatively as modified outputs for specific beam energy of linear accelerators, which eases the introduction of the IQM into clinical practice.

  1. Simulation of high-energy radiation belt electron fluxes using NARMAX-VERB coupled codes.

    Science.gov (United States)

    Pakhotin, I P; Drozdov, A Y; Shprits, Y Y; Boynton, R J; Subbotin, D A; Balikhin, M A

    2014-10-01

    This study presents a fusion of data-driven and physics-driven methodologies of energetic electron flux forecasting in the outer radiation belt. Data-driven NARMAX (Nonlinear AutoRegressive Moving Averages with eXogenous inputs) model predictions for geosynchronous orbit fluxes have been used as an outer boundary condition to drive the physics-based Versatile Electron Radiation Belt (VERB) code, to simulate energetic electron fluxes in the outer radiation belt environment. The coupled system has been tested for three extended time periods totalling several weeks of observations. The time periods involved periods of quiet, moderate, and strong geomagnetic activity and captured a range of dynamics typical of the radiation belts. The model has successfully simulated energetic electron fluxes for various magnetospheric conditions. Physical mechanisms that may be responsible for the discrepancies between the model results and observations are discussed.

  2. Advanced High Energy Density Secondary Batteries with Multi‐Electron Reaction Materials

    National Research Council Canada - National Science Library

    Chen, Renjie; Luo, Rui; Huang, Yongxin; Wu, Feng; Li, Li

    2016-01-01

    ...‐electron chemistry has paved a new path for the breaking of the barriers that exist in traditional battery research and applications, and provided new ideas for developing new battery systems...

  3. Advanced High Energy Density Secondary Batteries with Multi?Electron Reaction Materials

    OpenAIRE

    Chen, Renjie; Luo, Rui; Huang, Yongxin; Wu, Feng; Li, Li

    2016-01-01

    Secondary batteries have become important for smart grid and electric vehicle applications, and massive effort has been dedicated to optimizing the current generation and improving their energy density. Multi?electron chemistry has paved a new path for the breaking of the barriers that exist in traditional battery research and applications, and provided new ideas for developing new battery systems that meet energy density requirements. An in?depth understanding of multi?electron chemistries i...

  4. Reflection high-energy electron diffraction measurements of reciprocal space structure of 2D materials.

    Science.gov (United States)

    Xiang, Y; Guo, F-W; Lu, T-M; Wang, G-C

    2016-12-02

    Knowledge on the symmetry and perfection of a 2D material deposited or transferred to a surface is very important and valuable. We demonstrate a method to map the reciprocal space structure of 2D materials using reflection high energy diffraction (RHEED). RHEED from a 2D material gives rise to 'streaks' patterns. It is shown that from these streaks patterns at different azimuthal rotation angles that the reciprocal space intensity distribution can be constructed as a function of momentum transfer parallel to the surface. To illustrate the principle, we experimentally constructed the reciprocal space structure of a commercial graphene/SiO2/Si sample in which the graphene layer was transferred to the SiO2/Si substrate after it was deposited on a Cu foil by chemical vapor deposition. The result reveals a 12-fold symmetry of the graphene layer which is a result of two dominant orientation domains with 30° rotation relative to each other. We show that the graphene can serve as a template to grow other materials such as a SnS film that follows the symmetry of graphene.

  5. High-energy-density electron beam from interaction of two successive laser pulses with subcritical-density plasma

    Directory of Open Access Journals (Sweden)

    J. W. Wang

    2016-02-01

    Full Text Available It is shown by particle-in-cell simulations that a narrow electron beam with high energy and charge density can be generated in a subcritical-density plasma by two consecutive laser pulses. Although the first laser pulse dissipates rapidly, the second pulse can propagate for a long distance in the thin wake channel created by the first pulse and can further accelerate the preaccelerated electrons therein. Given that the second pulse also self-focuses, the resulting electron beam has a narrow waist and high charge and energy densities. Such beams are useful for enhancing the target-back space-charge field in target normal sheath acceleration of ions and bremsstrahlung sources, among others.

  6. Electrons and photons in periodic structures

    DEFF Research Database (Denmark)

    Pedersen, Jesper Goor

    with the numerically exact results we discuss the validity of certain approximative methods for calculating the exchange interaction. These ideas are applied also to graphene, where the emergence of a band gap is in itself interesting in that it turns the otherwise semimetallic graphene into a semiconductor, paving...... the way for graphene transistors. Photonic band gaps can be engineered using structures with a periodic modulations of the refractive index, commonly referred to as photonic crystal. We discuss the application of photonic crystals to slow light phenomena, where advantage is taken of the divergence...

  7. High energy electron beams characterization using CaSO{sub 4}:Dy+PTFE Phosphors for clinical therapy applications

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, T., E-mail: trivera@ipn.mx [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada-Legaria, IPN. Av. Legaria 694, Col. Irrigacion. 11500 Mexico DF (Mexico); Espinoza, A.; Von, S.M. [Centro Estatal de Cancerologia de los Servicios de Salud de Nayarit, Enfermeria S/n, Fracc, Fray Junipero Serra, 63169 Tepic Nay (Mexico); Alvarez, R.; Jimenez, Y. [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada-Legaria, IPN. Av. Legaria 694, Col. Irrigacion. 11500 Mexico DF (Mexico)

    2012-07-15

    In the present work high energy electron beam dosimetry from linear accelerator (LINACs) for clinical applications using dysprosium doped calcium sulfate embedded in polytetrafluorethylene (CaSO{sub 4}:Dy+PTFE) was studied. The irradiations were carried out using high electron beams (6 to 18 MeV) from a linear accelerator (LINAC) Varian, CLINAC 2300C/D, for clinical practice purpose. The electron irradiations were obtained using the water solid in order to guarantee electronic equilibrium conditions (EEC). Field shaping for electron beams was obtained with electron cones. Glow curve and other thermoluminescent characteristics of CaSO{sub 4}:Dy+PTFE were conducted under high electrons beams irradiations. The TL response of the pellets showed an intensity peak centered at around 215 Degree-Sign C. TL response of CaSO{sub 4}:Dy+PTFE as a function of high electron absorbed dose showed a linearity in a wide range. To obtain reproducibility characteristic, a set of pellets were exposed repeatedly for the same electron absorbed dose. The results obtained in this study can suggest the applicability of CaSO{sub 4}:Dy+PTFE pellets for high electron beam dosimetry, provided fading is correctly accounted for. - Highlights: Black-Right-Pointing-Pointer Developing of CaSO{sub 4}:Dy to electron beams dosimetry. Black-Right-Pointing-Pointer Characterization of caSO{sub 4}:Dy to radiation safety in LINACs. Black-Right-Pointing-Pointer TL characteristics of CaSO{sub 4}:Dy for electron beams quality control.

  8. Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans

    Energy Technology Data Exchange (ETDEWEB)

    Bazalova-Carter, Magdalena; Qu, Bradley; Palma, Bianey; Jensen, Christopher; Maxim, Peter G., E-mail: Peter.Maxim@Stanford.edu, E-mail: BWLoo@Stanford.edu; Loo, Billy W., E-mail: Peter.Maxim@Stanford.edu, E-mail: BWLoo@Stanford.edu [Department of Radiation Oncology, Stanford University, Stanford, California 94305 (United States); Hårdemark, Björn; Hynning, Elin [RaySearch Laboratories AB, Stockholm SE-103 65 (Sweden)

    2015-05-15

    Purpose: The aim of this work was to develop a treatment planning workflow for rapid radiotherapy delivered with very high-energy electron (VHEE) scanning pencil beams of 60–120 MeV and to study VHEE plans as a function of VHEE treatment parameters. Additionally, VHEE plans were compared to clinical state-of-the-art volumetric modulated arc therapy (VMAT) photon plans for three cases. Methods: VHEE radiotherapy treatment planning was performed by linking EGSnrc Monte Carlo (MC) dose calculations with inverse treatment planning in a research version of RayStation. In order to study the effect of VHEE treatment parameters on VHEE dose distributions, a MATLAB graphical user interface (GUI) for calculation of VHEE MC pencil beam doses was developed. Through the GUI, pediatric case MC simulations were run for a number of beam energies (60, 80, 100, and 120 MeV), number of beams (13, 17, and 36), pencil beam spot (0.1, 1.0, and 3.0 mm) and grid (2.0, 2.5, and 3.5 mm) sizes, and source-to-axis distance, SAD (40 and 50 cm). VHEE plans for the pediatric case calculated with the different treatment parameters were optimized and compared. Furthermore, 100 MeV VHEE plans for the pediatric case, a lung, and a prostate case were calculated and compared to the clinically delivered VMAT plans. All plans were normalized such that the 100% isodose line covered 95% of the target volume. Results: VHEE beam energy had the largest effect on the quality of dose distributions of the pediatric case. For the same target dose, the mean doses to organs at risk (OARs) decreased by 5%–16% when planned with 100 MeV compared to 60 MeV, but there was no further improvement in the 120 MeV plan. VHEE plans calculated with 36 beams outperformed plans calculated with 13 and 17 beams, but to a more modest degree (<8%). While pencil beam spacing and SAD had a small effect on VHEE dose distributions, 0.1–3 mm pencil beam sizes resulted in identical dose distributions. For the 100 MeV VHEE pediatric

  9. Evaluation of characteristics of high-energy electron beams using N-isopropyl-acrylamide gel dosimeter

    Science.gov (United States)

    Shih, Tian-Yu; Yen, Tsung-Hsien; Liu, Yan-Lin; Luzhbin, Dmytro; Wu, Jay

    2017-11-01

    The advantage of electron beam radiotherapy is that the absorbed dose rapidly decreases with the increasing depth, which can prevent damage to deeper organs and tissues. Accurately evaluating the absorbed dose in the superficial tumor is imperative. This study assessed the characteristics of electron beams by using the N-isopropyl-acrylamide (n-NIPAM) gel dosimeter. The n-NIPAM gel was composed of 6% gelatin, 5% monomer, and 2.5% cross-linker with 5 mM tetrakis (hydroxymethyl) phosphonium chloride for deoxygenation. The gel was irradiated with 6-, 9-, and 12-MeV electron beams with dose rates of 100-600 MU/min, respectively. The energy dependence and dose rate dependence were assessed. The beam profiles and percentage depth doses were measured and compared with the results of the Gafchromic film and ionization chamber. The linearity of the n-NIPAM gel under 6-, 9-, and 12-MeV electrons was larger than 0.990 with 2% variation in sensitivity. The sensitivity of the gel under 100-600 MU/min showed 5% variations. The energy and dose rate dependence can be negligible. The beam profiles and percentage depth doses measured by the n-NIPAM gel matched well with the results of the ionization chamber and film. This study reveals the possibility of using the n-NIPAM gel dosimeter for electron beam measurements in clinical radiotherapy.

  10. Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon beams

    Science.gov (United States)

    McEwen, Malcolm; DeWerd, Larry; Ibbott, Geoffrey; Followill, David; Rogers, David W. O.; Seltzer, Stephen; Seuntjens, Jan

    2014-01-01

    An addendum to the AAPM's TG-51 protocol for the determination of absorbed dose to water in megavoltage photon beams is presented. This addendum continues the procedure laid out in TG-51 but new kQ data for photon beams, based on Monte Carlo simulations, are presented and recommendations are given to improve the accuracy and consistency of the protocol's implementation. The components of the uncertainty budget in determining absorbed dose to water at the reference point are introduced and the magnitude of each component discussed. Finally, the consistency of experimental determination of ND,w coefficients is discussed. It is expected that the implementation of this addendum will be straightforward, assuming that the user is already familiar with TG-51. The changes introduced by this report are generally minor, although new recommendations could result in procedural changes for individual users. It is expected that the effort on the medical physicist's part to implement this addendum will not be significant and could be done as part of the annual linac calibration. PMID:24694120

  11. An investigation into electron scattering from pyrazine at intermediate and high energies

    Energy Technology Data Exchange (ETDEWEB)

    Sanz, A. G.; Fuss, M. C. [Instituto de Física Fundamental, Consejo Superior de Investigaciones Científicas, Serrano 113-bis, 28006 Madrid (Spain); Blanco, F. [Departamento de Física Atómica, Molecular y Nuclear, Universidad Complutense de Madrid, Ciudad Universitaria, 28040 Madrid (Spain); Gorfinkiel, J. D. [Department of Physical Sciences, The Open University, Walton Hall, Milton Keynes MK7 6AA (United Kingdom); Almeida, D.; Ferreira da Silva, F.; Limão-Vieira, P. [Laboratório de Colisões Atómicas e Moleculares, CEFITEC, Departamento de Física, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Brunger, M. J. [ARC Centre for Antimatter-Matter Studies, School of Chemical and Physical Sciences, Flinders University, GPO Box 2100, Adelaide, SA 5001 (Australia); Institute of Mathematical Sciences, University of Malaya, 50603 Kuala Lumpur (Malaysia); García, G., E-mail: g.garcia@iff.csic.es [Instituto de Física Fundamental, Consejo Superior de Investigaciones Científicas, Serrano 113-bis, 28006 Madrid (Spain); Centre for Medical Radiation Physics, University of Wollongong, NSW 2522 (Australia)

    2013-11-14

    Total electron scattering cross sections for pyrazine in the energy range 10–500 eV have been measured with a new magnetically confined electron transmission-beam apparatus. Theoretical differential and integral elastic, as well as integral inelastic, cross sections have been calculated by means of a screening-corrected form of the independent-atom representation (IAM-SCAR) from 10 to 1000 eV incident electron energies. The present experimental and theoretical total cross sections show a good level of agreement, to within 10%, in the overlapping energy range. Consistency of these results with previous calculations (i.e., the R-matrix and Schwinger Multichannel methods) and elastic scattering measurements at lower energies, below 10 eV, is also discussed.

  12. Total and elastic electron scattering cross sections from ozone at intermediate and high energies

    Energy Technology Data Exchange (ETDEWEB)

    Pablos, J.L. de; Garcia, G. [Departamento de Fusion y Particulas Elementales, CIEMAT, Madrid (Spain); Kendall, P.A.; Mason, N.J.; Tegeder, P. [Department of Physics and Astronomy, University College London, London (United Kingdom); Williart, A. [Departamento de Fisica de los Materiales, UNED, Madrid (Spain); Blanco, F. [Departamento de Fisica Atomica Molecular y Nuclear, Universidad Complutense de Madrid, Madrid (Spain)

    2002-02-28

    Total cross sections for electron scattering from O{sub 3} molecules in the energy range 350-5000 eV have been measured for the first time. The experimental method used was based on the measurement of the attenuation of a collimated electron beam through an O{sub 3}-O{sub 2} mixture in combination with use of an electron energy loss technique to determine the purity of the ozone sample. Differential and integral elastic cross sections have also been calculated using a scattering potential in the framework of the independent-atom model. The present theoretical and experimental results are compared with earlier calculations available in the literature. (author)

  13. High energy photoelectron spectroscopy in basic and applied science: Bulk and interface electronic structure

    Energy Technology Data Exchange (ETDEWEB)

    Knut, Ronny; Lindblad, Rebecka [Department of Physics and Astronomy, Uppsala University, SE-751 21 Uppsala (Sweden); Gorgoi, Mihaela [Helmholtz Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Str. 15, 12489 Berlin (Germany); Rensmo, Håkan [Department of Physics and Astronomy, Uppsala University, SE-751 21 Uppsala (Sweden); Karis, Olof, E-mail: olof.karis@physics.uu.se [Department of Physics and Astronomy, Uppsala University, SE-751 21 Uppsala (Sweden)

    2013-10-15

    Highlights: •We demonstrate how hard X-ray photoelectron spectroscopy can be used to investigate interface properties of multilayers. •By combining HAXPES and statistical methods we are able to provide quantitative analysis of the interface diffusion process. •We show how photoionization cross sections can be used to map partial density of states contributions to valence states. •We use HAXPES to provide insight into the valence electronic structure of e.g. multiferroics and dye-sensitized solar cells. -- Abstract: With the access of new high-performance electron spectrometers capable of analyzing electron energies up to the order of 10 keV, the interest for photoelectron spectroscopy has grown and many new applications of the technique in areas where electron spectroscopies were considered to have limited use have been demonstrated over the last few decades. The technique, often denoted hard X-ray photoelectron spectroscopy (HX-PES or HAXPES), to distinguish the experiment from X-ray photoelectron spectroscopy performed at lower energies, has resulted in an increasing interest in photoelectron spectroscopy in many areas. The much increased mean free path at higher kinetic energies, in combination with the elemental selectivity of the core level spectroscopies in general has led to this fact. It is thus now possible to investigate the electronic structure of materials with a substantially enhanced bulk sensitivity. In this review we provide examples from our own research using HAXPES which to date has been performed mainly at the HIKE facility at the KMC-1 beamline at HZB, Berlin. The review exemplifies the new opportunities using HAXPES to address both bulk and interface electronic properties in systems relevant for applications in magnetic storage, energy related research, but also in purely curiosity driven problems.

  14. Analysis of Voyager Observed High-Energy Electron Fluxes in the Heliosheath Using MHD Simulations

    Science.gov (United States)

    Washimi, Haruichi; Webber, W. R.; Zank, Gary P.; Hu, Qiang; Florinski, Vladimir; Adams, James; Kubo, Yuki

    2011-01-01

    The Voyager spacecraft (V1 and V2) observed electrons of 6-14 MeV in the heliosheath which showed several incidences of flux variation relative to a background of gradually increasing flux with distance from the Sun. The increasing flux of background electrons is thought to result from inward radial diffusion. We compare the temporal electron flux variation with dynamical phenomena in the heliosheath that are obtained from our MHD simulations. Because our simulation is based on V2 observed plasma data before V2 crossed the termination shock, this analysis is effective up to late 2008, i.e., about a year after the V2-crossing, during which disturbances, driven prior to the crossing time, survived in the heliosheath. Several electron flux variations correspond to times directly associated with interplanetary shock events. One noteworthy example corresponds to various times associated with the March 2006 interplanetary shock, these being the collision with the termination shock, the passage past the V1 spacecraft, and the collision with the region near the heliopause, as identified by W.R. Webber et al. for proton/helium of 7-200 MeV. Our simulations indicate that all other electron flux variations, except one, correspond well to the times when a shock-driven magneto-sonic pulse and its reflection in the heliosheath either passed across V1/V2, or collided with the termination shock or with the plasma sheet near the heliopause. This result suggests that variation in the electron flux should be due to either direct or indirect effects of magnetosonic pulses in the heliosheath driven by interplanetary shocks

  15. Scalar electron production in e/sup +/ e/sup -/ annihilation at high energies

    Energy Technology Data Exchange (ETDEWEB)

    Hayashibara, I.; Takasaki, F.; Shimizu, Y.; Kuroda, M.

    1985-08-22

    The cross section for single and pair productions of scalar electrons in e/sup +/e/sup -/ annihilation are calculated in the energy range of TRISTAN, SLC and LEP with specific emphasis on the contribution from the Z/sup 0/ boson and the zino. (orig.).

  16. Scalar electron production in e/sup +/ e annihilation at high energies

    Energy Technology Data Exchange (ETDEWEB)

    Hayashibara, I.; National Lab. for High Energy Physics, Tsukuba, Itabashi; Takasaki, F.; Shimizu, Y.; Kuroda, M.

    1985-08-22

    The cross section for single and pair productions of scalar electrons in e/sup +/e annihilation are calculated in the energy range of TRISTAN, SLC and LEP with specific emphasis on the contribution from the Z/sup 0/ boson and the zino. (orig.).

  17. Aerrow: A probe-format graphite calorimeter for absolute dosimetry of high-energy photon beams in the clinical environment.

    Science.gov (United States)

    Renaud, James; Sarfehnia, Arman; Bancheri, Julien; Seuntjens, Jan

    2018-01-01

    In this work, the design, operation, initial experimental evaluation, and characterization of a small-scale graphite calorimeter probe - herein referred to as the Aerrow - developed for routine use in the clinical environment, are described. Similar in size and shape to a Farmer type cylindrical ionization chamber, the Aerrow represents the first translation of calorimetry intended for direct use by clinical physicists in the radiotherapy clinic. Based on a numerically optimized design obtained in previous work, a functioning Aerrow prototype capable of two independent modes of operation (quasi-adiabatic and isothermal) was constructed in-house. Reference dose measurements were performed using both Aerrow operation modes in a 6 MV photon beam and were directly compared to results obtained with a calibrated reference-class ionization chamber. The Aerrow was then used to quantify the absolute output of five clinical linac-based photon beams (6 MV, 6 MV FFF, 10 MV, 10 MV FFF, and 15 MV; 63.2% < %dd(10)× < 76.3%). Linearity, dose rate, and orientation dependences were also investigated. Compared to an ion chamber-derived dose to water of 76.3 ± 0.7 cGy, the average doses measured using the Aerrow were 75.6 ± 0.7 and 74.7 ± 0.7 cGy/MU for the quasi-adiabatic and isothermal modes, respectively. All photon beam output measurements using the Aerrow in water-equivalent phantom agreed with chamber-based clinical reference dosimetry data within combined standard uncertainties. The linearity of the Aerrow's response was characterized by an adjusted R2 value of 0.9998 in the dose range of 80 cGy to 470 cGy. For the dose-rate dependence, no statistically significant effects were observed in the range of 0.5 Gy/min to 5.4 Gy/min. A relative photon beam quality dependence of 1.7% was calculated in the range of 60 Co to 24 MV (58.4% < %dd(10)× < 86.8%) using Monte Carlo. Finally, the angular dependence (gantry stationary and detector rotated) of the

  18. Nonlinear Structuring and High-energy Electrons: Role in Ionosphere and in Thunderstorm Atmosphere Processes

    Science.gov (United States)

    2010-05-01

    elastic and inelastic scattering at the atom as a whole to the Coulomb scattering at the electrons and the atomic nucleus . To describe this process...wave scattering off these structures. 3. The theory of the high-altitude thunder discharges generating of the powerful gamma emission, powerful...UHF radio wave scattering off these structures. 3. The theory of the high-altitude thunder discharges generating of the powerful gamma emission

  19. Analysis of $\\pi^{0},\\eta$ and $\\omega$ mesons in pp collisions with a high energy photon trigger at ALICE

    CERN Document Server

    Yano, Satoshi

    High energy heavy ion collision is a powerful and unique tool to achieve the high density and temperature like the early universe. At normal temperature, partons are confined in nucleons and they can not move freely due to the asymp- totic freedom which is a property of the Quantum Chromo Dynamics (QCD). However, at high density and/or high temperature, they can be deconfined from nucleons. This phase is called the Quark Gluon Plasma (QGP). Hadron production measurements in proton-proton collisions at the Large Hadron Collider (LHC) energies can observe new phenomena which must be a frontier in the particle physics and allow validation of the predictive power of the QCD and can provide further constrains on pQCD theory for LHC energies. It is well known that the yield of high transvers momentum particles is suppressed in nucleus-nucleus collisions relative to that in proton-proton collisions. This effect is attributed to energy loss of parent partons or perhaps of hadrons after freeze-out. Since π 0 , η and...

  20. A proposal for fs-electron microscopy experiments on high-energy excitations in solids.

    Science.gov (United States)

    Piazza, L; Musumeci, P; Luiten, O J; Carbone, Fabrizio

    2014-08-01

    Recent advances in ultrafast technology enable both the study and the control of materials properties thanks to the ability to record high temporal resolution movies of their transformations, or the ability to generate new states of matter by selecting ad hoc an excitation to drive the system out of equilibrium. The holy grail of this type of experiments is to combine a high tuneability of the excitation with a wide observation window. For example, this is achieved in multidimensional optical spectroscopy where the response to several excitation energies is monitored in a broad energy range by a large bandwidth optical pulse. In this article, the possibility to combine the chemical sensitivity of intense tuneable X-rays pulses from a free electron laser, with the wide range of observables available in an ultrafast transmission electron microscope is discussed. The requirements for such experiments are quantified via estimates based on state of the art experiments and simulations, and it is proposed that ultrafast electron imaging, diffraction and spectroscopy experiments can be performed in combination with a chemically selective X-ray excitation of materials. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Dynamics of the microstructure of current channels and the generation of high-energy electrons in nanosecond discharges in air

    Energy Technology Data Exchange (ETDEWEB)

    Karelin, V. I.; Trenkin, A. A., E-mail: trenkin@ntc.vniief.ru; Fedoseev, I. G. [Russian Federal Nuclear Center VNIIEF (Russian Federation)

    2015-12-15

    The results of the three-dimensional numerical simulation of the dynamics of the microstructure of high-voltage nanosecond discharges in air at atmospheric pressure are presented. It is established that the fast (at a time of ≈10 ns) broadening and significant decrease in the gas concentration in the microchannels occur as a result of the ohmic heating of microchannels with the diameter of 1–30 μm. It was shown that the broadening of microchannels in a nanosecond diffusive discharge provides an increase in the ratio of the electric field strength to the gas concentration in microchannels to values sufficient for the generation highenergy electron beams and X-ray bremsstrahlung in them. Features of the dynamics of the system of microchannels and its effect on the efficiency of the generation of high-energy electrons in discharges developing in the microstructuring regime of the current channels are considered.

  2. Metrology and quality of radiation therapy dosimetry of electron, photon and epithermal neutron beams

    Science.gov (United States)

    Kosunen, Antti

    In radiation therapy using electron and photon beams the dosimetry chain consists of several sequential phases starting by the realization of the dose quantity in the Primary Standard Dosimetry Laboratory and ending to the calculation of the dose to a patient. A similar procedure can be described for the dosimetry of epithermal neutron beams in boron neutron capture therapy (BNCT). This work is focused on two items in the dosimetry chains: the determination of the dose in the reference conditions and the evaluation of the accuracy of dose calculation methods. The issues investigated and discussed in detail are: (a)the calibration methods of plane parallel ionization chambers used in electron beam dosimetry, (b)the specification of the critical dosimetric parameter i.e. the ratio of stopping powers for water to air, (S/r) waterair , in photon beams, (c)the feasibility of the twin ionization chamber technique for dosimetry in epithermal neutron beams applied to BNCT and (d)the determination accuracy of the calculated dose distributions in phantoms in electron, photon, and epithermal neutron beams. The results demonstrate that UP to a 3% improvement in the consistency of dose determinations in electron beams is achieved by the calibration of plane parallel ionization chambers in high energy electron beams instead of calibrations in 60Co gamma beams. In photon beam dosimetry (S/r) waterair can be determined with an accuracy of 0.2% using the percentage dose at the 10 cm depth, %dd(10), as a beam specifier. By a twin ionization chamber technique accuracy the gamma dose can be determined with uncertainty of 6% (1 standard deviation) and the total neutron dose with an uncertainty of 15 to 20% (1 standard deviation). The general accuracy achieved by treatment planning systems is approximately 4% for photons and 5 to 7% for electrons. Large (>10%) deviations in calculated doses are possible even when relatively modern calculation approaches are used.

  3. Advanced photonic, electronic, and web engineering systems: WILGA Symposium, January 2013

    Science.gov (United States)

    Romaniuk, Ryszard S.

    2013-10-01

    The cycle of WILGA Symposia [wilga.ise.pw.edu.pl] on Photonics and Web Engineering, Advanced Electronic Systems, under the auspices of SPIE, IEEE, KEiT PAN and WEiTI PW was initiated in 1998 by a Research Team PERG/ELHEP ISE PW. The WILGA conferences take place two times a year and the participants are young scientists from this country and abroad. This paper debates chosen topical tracks and some papers presented during the 31 WILGA Multi-Conference, which took place on 8-10 February 2013 at the Faculty of WEiTI PW. The January conference was attended by around 100 persons. Here we discuss closer the subjects of biomedical photonics, electronics and informatics, as well as chosen aspects of applications of advanced photonic, electronic circuits and systems. The 32 nd WILGA Symposium took place on 27 May - 02 June 2013 in WUT WILGA resort near Warsaw. These two editions of WILGA Conferences - January and May have generated more than 250 articles, from which around 100 were chosen by the Symposium and Conference Committees to be published in this volume of Proc.SPIE. WILGA Symposium papers are traditionally submitted via the WILGA web page [wilga.ise.pw.edu.pl] to the SPIE Proceedings publishing system [spie.org]. Email for the correspondence is: photonics@ise.pw.edu.pl. All Wilga papers are published in journals Elektronika, IJET-PAN and in Proc.SPIE. Topical tracks of the symposium usually embrace, among others, new technologies for photonics, sensory and nonlinear optical fibers, object oriented design of hardware, photonic metrology, optoelectronics and photonics applications, photonics-electronics co-design, optoelectronic and electronic systems for astronomy and high energy physics experiments, JET and pi-of-the sky experiments development. The symposium In its two editions a year is a summary of the development of numerable Ph.D. theses carried out in this country and this geographical region in the area of advanced electronic and photonic systems. It is also

  4. Experimental study of high energy electron interactions in a superconducting aluminum alloy resonant bar

    CERN Document Server

    Barucci, M; Buonomo, B; Cavallari, G; Coccia, E; D'Antonio, S; Fafone, V; Ligi, C; Lolli, L; Marini, A; Mazzitelli, G; Modestino, G; Pizzella, G; Quintieri, L; Risegari, L; Rocchi, A; Ronga, F; Valente, P; Ventura, G; Vinko, S M

    2009-01-01

    Peak amplitude measurements of the fundamental mode of oscillation of a suspended aluminum alloy bar hit by an electron beam show that the amplitude is enhanced by a factor ~3.5 when the material is in the superconducting state. This result is consistent with the cosmic ray observations made by the resonant gravitational wave detector NAUTILUS, made of the same alloy, when operated in the superconducting state. A comparison of the experimental data with the predictions of the model describing the underlying physical process is also presented.

  5. Magnifying Lenses with Weak Achromatic Bends for High-Energy Electron Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Walstrom, Peter Lowell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-02-27

    This memo briefly describes bremsstrahlung background effects in GeV-range electron radiography systems and the use of weak bending magnets to deflect the image to the side of the forward bremsstrahlung spot to reduce background. The image deflection introduces first-order chromatic image blur due to dispersion. Two approaches to eliminating the dispersion effect to first order by use of magnifying lens with achromatic bends are described. Also, higher-order image blur terms caused by weak bends are also discussed, and shown to be negligibly small in most cases of interest.

  6. Performance of a Tungsten-Cerium Fluoride Sampling Calorimeter in High-Energy Electron Beam Tests

    CERN Document Server

    Becker, R.; Dissertori, G.; Djambazov, L.; Donega, M.; Lustermann, W.; Marini, A.C.; Nessi-Tedaldi, F.; Pandolfi, F.; Peruzzi, M.; Schönenberger, M.; Cavallari, F.; Dafinei, I.; Diemoz, M.; Lope, C. Jorda; Meridiani, P.; Nuccetelli, M.; Paramatti, R.; Pellegrino, F.; Micheli, F.; Organtini, G.; Rahatlou, S.; Soffi, L.; Brianza, L.; Govoni, P.; Martelli, A.; Tabarelli de Fatis, T.; Monti, V.; Pastrone, N.; Trapani, P.P.; Candelise, V.; Della Ricca, G.

    2015-12-21

    A prototype for a sampling calorimeter made out of cerium fluoride crystals interleaved with tungsten plates, and read out by wavelength-shifting fibres, has been exposed to beams of electrons with energies between 20 and 150 GeV, produced by the CERN Super Proton Synchrotron accelerator complex. The performance of the prototype is presented and compared to that of a Geant4 simulation of the apparatus. Particular emphasis is given to the response uniformity across the channel front face, and to the prototype's energy resolution.

  7. Sub electron readout noise & photon counting devices

    Science.gov (United States)

    Gach, J.-L.; Balard, Ph.; Daigle, O.; Destefanis, G.; Feautrier, Ph.; Guillaume, Ch.; Rothman, J.

    We present recent advances on ultra low noise visible detectors at Laboratoire d'Astrophysique de Marseille, photon counting and EMCCD developments in collaboration with Observatoire de haute provence, Laboratoire d'astrophysique de l'observatoire de Grenoble and Laboratoire d'Astrophysique Experimentale (Montreal). After a review of the progress with third generation Image Photon Counting Systems (IPCS), we present the OCAM camera, based on the E2V CCD220 EMCCD, part of the Opticon JRA2 programme, and the CCCP controller, a new controller for the 3DNTT instrument that reduces the clock induced charge of an EMCCD by a factor 10, making it competitive with IPCS detectors for very faint fluxes. We will finally present the RAPID project and the concept of photon counting avalanche photodiode CMOS device (in collaboration with CEA-LETI) which is foreseen to be the ultimate detector for the visible-IR range providing no readout noise, high QE and extremely fast readout.

  8. High energy electron and ion generation from thin target using ultra short table top laser

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, K.; Oishi, Y.; Fujii, T.; Nayuki, T.; Takizawa, Y. [Central Research Institute of Electric Power Industry, Tokyo (Japan); Sekiya, T; Okano, Y.; Hironaka, Y.; Nakamura, K. G.; Horioka, K.; Kondo, K. [Materials and Structures Laboratory, Toyko Institute of Technology, Tokyo (Japan)

    2003-07-01

    The influence of laser pulse duration on energetic electrons and protons generation was investigated using a Ti:sapphire laser. Energetic electrons with the temperature of 350 keV were produced by the irradiation of 90 mJ and 50 fs pulse onto a 30 {mu} m copper tape target. For ions, when laser pulse was changed by varying grating distance in the pulse compressor with keeping laser energy at constant value, the maximum proton energy was not changed so much in the region where laser pulse duration was between 55 fs and 400 fs and laser intensity was order of 10{sup 18} W/ cm{sup 2}. The maximum proton energy seems to more depend on the laser energy density on the target than laser intensity. When we evaluate the performance of ion acceleration using the value of E{sub p-max}/U{sub p} (the maximum proton energy normalized by the ponderomotive potential of the laser field), it increasing along with increasing of laser pulse duration.

  9. Electron-positron pair production by ultrarelativistic electrons in a soft photon field

    Science.gov (United States)

    Mastichiadis, A.; Marscher, A. P.; Brecher, K.

    1986-01-01

    The fully differential cross section for photon-electron pair production is integrated numerically over phase space. Results are obtained for the astrophysically interesting case in which the interaction between an ultrarelativistic electron and a soft photon results in electron-positron pair production. The positron spectrum is a function of the energies of both the photon and the electron, as well as the angle of interaction. It is found that the energy at which the positron distribution peaks is inversely proportional to the photon energy and independent of the electron energy. The positron spectrum is integrated once more over initial electron energies for a power-law energy distribution of primary electrons. The same procedure is repeated for the recoil particle; it is shown that the peak of the recoil energy distribution depends linearly on the energy of the primary electron. Finally, semianalytical expressions are obtained for the energy losses of the primary electrons.

  10. Proceedings of the 1984 workshop on high-energy excitations in condensed matter. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Silver, R.N. (comp.)

    1984-12-01

    This volume covers electronic excitations, momentum distributions, high energy photons, and a wrap-up session. Abstracts of individual items from the conference were prepared separately for the data base. (GHT)

  11. Capturing relativistic wakefield structures in plasmas using ultrashort high-energy electrons as a probe.

    Science.gov (United States)

    Zhang, C J; Hua, J F; Xu, X L; Li, F; Pai, C-H; Wan, Y; Wu, Y P; Gu, Y Q; Mori, W B; Joshi, C; Lu, W

    2016-07-11

    A new method capable of capturing coherent electric field structures propagating at nearly the speed of light in plasma with a time resolution as small as a few femtoseconds is proposed. This method uses a few femtoseconds long relativistic electron bunch to probe the wake produced in a plasma by an intense laser pulse or an ultra-short relativistic charged particle beam. As the probe bunch traverses the wake, its momentum is modulated by the electric field of the wake, leading to a density variation of the probe after free-space propagation. This variation of probe density produces a snapshot of the wake that can directly give many useful information of the wake structure and its evolution. Furthermore, this snapshot allows detailed mapping of the longitudinal and transverse components of the wakefield. We develop a theoretical model for field reconstruction and verify it using 3-dimensional particle-in-cell (PIC) simulations. This model can accurately reconstruct the wakefield structure in the linear regime, and it can also qualitatively map the major features of nonlinear wakes. The capturing of the injection in a nonlinear wake is demonstrated through 3D PIC simulations as an example of the application of this new method.

  12. Hidden-Sector Higgs Bosons at a High-Energy Electron-Positron Collider

    CERN Document Server

    Collins, J.H.

    2012-01-01

    The possibility of a scalar messenger that can couple the Standard Model (SM) to a hidden sector has been discussed in a variety of contexts in the literature in recent years. We consider the case that a new scalar singlet charged under an exotic spontaneously broken Abelian gauge symmetry mixes weakly with the SM Higgs resulting in two scalar mass states, one of which has heavily suppressed couplings to the SM particles. Previous phenomenological studies have focussed on potential signatures for such a model at the Large Hadron Collider (LHC). However, there are interesting regions of the parameter space in which the heavier Higgs state would be just out of reach for LHC searches if its mass is & 1 TeV. We therefore investigate the discovery potential for such a particle at a 3 TeV electron-positron collider, which is motivated by the recent R&D developments of the Compact Linear Collider (CLIC). We find that such an experiment could substantially extend our discovery reach for a heavy, weakly couple...

  13. Hidden-Sector Higgs Bosons at High-Energy Electron-Positron Colliders

    CERN Document Server

    Collins, Jack H.

    2012-01-01

    The possibility of a scalar messenger that can couple the Standard Model (SM) to a hidden sector has been discussed in a variety of contexts in the literature in recent years. We consider the case that a new scalar singlet charged under an exotic spontaneously broken Abelian gauge symmetry mixes weakly with the SM Higgs resulting in two scalar mass states, one of which has heavily suppressed couplings to the SM particles. Previous phenomenological studies have focussed on potential signatures for such a model at the Large Hadron Collider (LHC). However, there are interesting regions of the parameter space in which the heavier Higgs state would be out of reach for LHC searches if its mass is greater than 1 TeV. We therefore investigate the discovery potential for such a particle at a 3 TeV electron-positron collider, which is motivated by the recent developments of the Compact Linear Collider (CLIC). We find that such an experiment could substantially extend our discovery reach for a heavy, weakly coupled Higg...

  14. Capturing relativistic wake eld structures in plasmas using ultrashort high-energy electrons as a probe

    CERN Document Server

    Zhang, C J; Xu, X L; Li, F; Pai, C -H; Wan, Y; Wu, Y P; Gu, Y Q; Mori, W B; Joshi, C; Lu, W

    2016-01-01

    A new method capable of capturing coherent electric field structures propagating at nearly the speed of light in plasma with a time resolution as small as a few femtoseconds is proposed. This method uses a few femtoseconds long relativistic electron bunch to probe the wake produced in a plasma by an intense laser pulse or an ultra-short relativistic charged particle beam. As the probe bunch traverses the wake, its momentum is modulated by the electric field of the wake, leading to a density variation of the probe after free-space propagation. This variation of probe density produces a snapshot of the wake that can directly give many useful information of the wake structure and its evolution. Furthermore, this snapshot allows detailed mapping of the longitudinal and transverse components of the wakefield. We develop a theoretical model for field reconstruction and verify it using 3-dimensional particle-in-cell (PIC) simulations. This model can accurately reconstruct the wakefield structure in the linear regime...

  15. A method for estimating the temperature in high energy density free electron laser experiments

    Energy Technology Data Exchange (ETDEWEB)

    Principi, Emiliano, E-mail: emiliano.principi@unicam.i [CNISM, Dipartimento di Fisica, Universita degli Studi di Camerino via Madonna delle Carceri, I-62032 Camerino (Italy); Ferrante, Carino; Filipponi, Adriano [Dipartimento di Fisica, Universita degli Studi dell' Aquila, Via Vetoio, I-67100 L' Aquila (Italy); Bencivenga, Filippo; D' Amico, Francesco; Masciovecchio, Claudio [Synchrotron ELETTRA, Strada Statale 14-I-34149 Basovizza, Trieste (Italy); Di Cicco, Andrea [CNISM, Dipartimento di Fisica, Universita degli Studi di Camerino via Madonna delle Carceri, I-62032 Camerino (Italy); IMPMC, Universite Paris 6, CNRS, 140 rue de Lourmel, 75015 Paris (France)

    2010-09-21

    Present and forthcoming free electron laser (FEL) large scale facilities deliver high fluence ultrafast soft and hard X-ray pulses able to create and probe warm dense matter (WDM). Proper diagnostic for basic physical quantities, like temperature and density, is necessary, but the short lifetime of the WDM state (few ps) makes their measurements a challenging task. In this work we propose a method to estimate the WDM temperature using the experimental information from a slow temperature pyrometric probe exploiting the properties of the heat diffusion equation. Numerical simulations show that for typical thin foil samples, a temperature measurement with 1-10{mu}s temporal resolution at the distance of about 300-500{mu}m from the beam center contains sufficient information to retrieve the initial spatial temperature distribution with sufficient accuracy providing information on the temperature reached in the WDM regime. The inversion of the experimental information is obtained by means of a Bayesian approach exploiting a Metropolis Monte Carlo numerical procedure. The model and calculations presented in this work provide the theoretical background for the development of a device for temperature diagnostics of the TIMEX end-station at the Fermi-Elettra FEL facility.

  16. Delivery of high energy Er:YAG pulsed laser light at 2.94 µm through a silica hollow core photonic crystal fibre.

    Science.gov (United States)

    Urich, A; Maier, R R J; Mangan, B J; Renshaw, S; Knight, J C; Hand, D P; Shephard, J D

    2012-03-12

    In this paper the delivery of high power Er:YAG laser pulses through a silica hollow core photonic crystal fibre is demonstrated. The Er:YAG wavelength of 2.94 µm is well beyond the normal transmittance of bulk silica but the unique hollow core guidance allows silica to guide in this regime. We have demonstrated for the first time the ability to deliver high energy pulses through an all-silica fibre at 2.94 µm. These silica fibres are mechanically and chemically robust, biocompatible and have low sensitivity to bending. A maximum pulse energy of 14 mJ at 2.94 µm was delivered through the fibre. This, to our knowledge, is the first time a silica hollow core photonic crystal fibre has been shown to transmit 2.94 μm laser light at a fluence exceeding the thresholds required for modification (e.g. cutting and drilling) of hard biological tissue. Consequently, laser delivery systems based on these fibres have the potential for the realization of novel, minimally-invasive surgical procedures.

  17. Metrology and quality of radiation therapy dosimetry of electron, photon and epithermal neutron beams

    Energy Technology Data Exchange (ETDEWEB)

    Kosunen, A

    1999-08-01

    In radiation therapy using electron and photon beams the dosimetry chain consists of several sequential phases starting by the realisation of the dose quantity in the Primary Standard Dosimetry Laboratory and ending to the calculation of the dose to a patient. A similar procedure can be described for the dosimetry of epithermal neutron beams in boron neutron capture therapy (BNCT). To achieve the required accuracy of the dose delivered to a patient the quality of all steps in the dosimetry procedure has to be considered. This work is focused on two items in the dosimetry chains: the determination of the dose in the reference conditions and the evaluation of the accuracy of dose calculation methods. The issues investigated and discussed in detail are: a)the calibration methods of plane parallel ionisation chambers used in electron beam dosimetry, (b) the specification of the critical dosimetric parameter i.e. the ratio of stopping powers for water to air, (S I ?){sup water} {sub air}, in photon beams, (c) the feasibility of the twin ionization chamber technique for dosimetry in epithermal neutron beams applied to BNCT and (d) the determination accuracy of the calculated dose distributions in phantoms in electron, photon, and epithermal neutron beams. The results demonstrate that up to a 3% improvement in the consistency of dose determinations in electron beams is achieved by the calibration of plane parallel ionisation chambers in high energy electron beams instead of calibrations in {sup 60}Co gamma beams. In photon beam dosimetry (S I ?){sup water} {sub air} can be determined with an accuracy of 0.2% using the percentage dose at the 10 cm depth, %dd(10), as a beam specifier. The use of %odd(10) requires the elimination of the electron contamination in the photon beam. By a twin ionisation chamber technique the gamma dose can be determined with uncertainty of 6% (1 standard deviation) and the total neutron dose with an uncertainty of 15 to 20% (1 standard deviation

  18. Clinical application of in vivo treatment delivery verification based on PET/CT imaging of positron activity induced at high energy photon therapy

    Science.gov (United States)

    Janek Strååt, Sara; Andreassen, Björn; Jonsson, Cathrine; Noz, Marilyn E.; Maguire, Gerald Q., Jr.; Näfstadius, Peder; Näslund, Ingemar; Schoenahl, Frederic; Brahme, Anders

    2013-08-01

    The purpose of this study was to investigate in vivo verification of radiation treatment with high energy photon beams using PET/CT to image the induced positron activity. The measurements of the positron activation induced in a preoperative rectal cancer patient and a prostate cancer patient following 50 MV photon treatments are presented. A total dose of 5 and 8 Gy, respectively, were delivered to the tumors. Imaging was performed with a 64-slice PET/CT scanner for 30 min, starting 7 min after the end of the treatment. The CT volume from the PET/CT and the treatment planning CT were coregistered by matching anatomical reference points in the patient. The treatment delivery was imaged in vivo based on the distribution of the induced positron emitters produced by photonuclear reactions in tissue mapped on to the associated dose distribution of the treatment plan. The results showed that spatial distribution of induced activity in both patients agreed well with the delivered beam portals of the treatment plans in the entrance subcutaneous fat regions but less so in blood and oxygen rich soft tissues. For the preoperative rectal cancer patient however, a 2 ± (0.5) cm misalignment was observed in the cranial-caudal direction of the patient between the induced activity distribution and treatment plan, indicating a beam patient setup error. No misalignment of this kind was seen in the prostate cancer patient. However, due to a fast patient setup error in the PET/CT scanner a slight mis-position of the patient in the PET/CT was observed in all three planes, resulting in a deformed activity distribution compared to the treatment plan. The present study indicates that the induced positron emitters by high energy photon beams can be measured quite accurately using PET imaging of subcutaneous fat to allow portal verification of the delivered treatment beams. Measurement of the induced activity in the patient 7 min after receiving 5 Gy involved count rates which were about

  19. Infusing photonics to increase enrollment in electronics engineering technology

    Science.gov (United States)

    Panayiotou, Chrys A.; Seeber, Fred P.

    2007-06-01

    During the last 15 years most of the electronics engineering technology programs across the nation have experienced a constant decline in enrollment. Today's high school students do not seem to consider a career in electronics engineering appealing enough to commit to a field of study in desperate need of new students. They still associate electronics programs with the electronics section of a department store; televisions, stereo systems, DVD and VCR players, and other disposable electronics. While the downward trend continues across the nation, Indian River Community College (IRCC) has been able not only to stop it but to reverse it by attracting a new generation of students. By introducing high school students to new and emerging technologies, their perception of established degrees has changed and their interest has been stimulated. Photonics is one of those technologies capturing students' attention. IRCC, a partner college in the National Center for Optics and Photonics Education (OP-TEC), with the assistance of other colleges like Camden County College which already offers an Associate in Applied Science degree in Photonics, has created a Photonics specialization under the Electronics Engineering Technology program. The targeted marketing of this new specialization has led to an increase in enrollment of 50% in 2005, 80% in 2006, and for 2007 it is projected it to be over 100%. An interesting comparison can be made concerning enrollment at colleges with a full AAS program in photonics like Camden County College and IRCC which uses photonics as an enabling technology. This analysis could lead to a new approach in restructuring engineering technology degrees with the infusion of photonics throughout many technology fields. This presentation will discuss the plan of action that made possible this initiative at Indian River Community College and new program directions at Camden County College, Blackwood, New Jersey.

  20. Effect of high energy electron irradiation on low frequency noise in 4H-SiC Schottky diodes

    Science.gov (United States)

    Kozlovski, V. V.; Lebedev, A. A.; Levinshtein, M. E.; Rumyantsev, S. L.; Palmour, J. W.

    2017-03-01

    The low-frequency noise in high voltage Ni/4H-SiC Schottky diodes irradiated with high energy (0.9 MeV) electrons was studied in the frequency range from 1 Hz to 50 kHz, temperature interval 295-410 K, and irradiation dose Φ from 0.2 × 1016 cm-2 to 7 × 1016 cm-2. The noise amplitude was found monotonically increasing with the irradiation dose. With the irradiation dose increase, the noise spectra on the linear part of the current voltage characteristic transform from the 1/f noise to the generation recombination noise of at least two trap levels. One of these levels can be classified as Z1/2 with the capture cross section determined from the noise measurements to be ˜10-15 cm2.

  1. Search for new physics in final states with a high energy electron and large missing transverse energy

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00345099

    The most successful and comprehensive theory describing the microcosm is the Standard Model of particle physics (SM). It comprises all known elementary particles and describes in high precision the basic processes of three of the four fundamental interactions. But still, not all experimental observations and theoretical challenges are covered. Many models exist that take the SM as a good approximation of natural phenomena in already discovered energy regions, but extend it in various ways. The Large Hadron Collider (LHC) provides the opportunity to look into these high energy regions using proton-proton collisions at significantly higher center-of-mass energies than previous experiments. This dissertation searches for physics beyond the SM especially in final states with one highly energetic electron (respectively positron) and large missing transverse energy. With the data set recorded in 2012 by the ATLAS detector, a large multi-purpose detector making use of the LHC, the spectrum of the related combined ...

  2. Improved ethanol production of a newly isolated thermotolerant Saccharomyces cerevisiae strain after high-energy-pulse-electron beam.

    Science.gov (United States)

    Zhang, Q; Fu, Y; Wang, Y; Han, J; Lv, J; Wang, S

    2012-02-01

    To isolate thermotolerant Saccharomyces cerevisiae with high-energy-pulse-electron (HEPE) beam, to optimize the mutation strain fermentation conditions for ethanol production and to conduct a preliminary investigation into the thermotolerant mechanisms. After HEPE beam radiation, the thermotolerant S. cerevisiae strain Y43 was obtained at 45°C. Moreover, the fermentation conditions of mutant Y43 were optimized by L3(3) orthogonal experiment. The optimal glucose content and initial pH for fermentation were 20% g l(-1) and 4·5, respectively; peptone content was the most neglected important factor. Under this condition, ethanol production of Y43 was 83·1 g l(-1) after fermentation for 48 h at 43°C, and ethanol yield was 0·42 g g(-1), which was about 81·5% of the theoretical yield. The results also showed that the trehalose content and the expression of the genes MSN2, SSA3 and TPS1 in Y43 were higher than those in the original strain (YE0) under the same stress conditions. A genetically stable mutant strain with high ethanol yield under heat stress was obtained using HEPE. This mutant may be a suitable candidate for the industrial-scale ethanol production. High-energy-pulse-electron radiation is a new efficient technology in breeding micro-organisms. The mutant obtained in this work has the advantages in industrial ethanol production under thermostress. © 2012 The Authors. Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.

  3. Determination of the charge radii of several light nuclei from precision, high-energy electron elastic scattering

    Energy Technology Data Exchange (ETDEWEB)

    Kabir, Al Amin [Kent State Univ., Kent, OH (United States)

    2015-12-01

    Analysis of high-energy electron scattering has been used to determine the charge radii of nuclei for several decades. Recent analysis of the Lamb shift in muonic hydrogen found an r.m.s. radius significantly different than the electron scattering result. To understand this puzzle we have analyzed the "LEDEX" data for the (e, e'p) reaction. This experiment includes measurements on several light nuclei, hydrogen, deuterium, lithium, boron, and carbon. To test our ability to measure absolute cross sections, as well as our ability to extract the charge radius, we tested our technique against the extremely well-measured carbon case and found excellent agreement using the Fourier-Bessel parametrization. We then extended the procedure to boron and lithium, which show nice agreement with the latest theoretical calculations. For hydrogen, we see clearly the limits of this technique and therefore, the charge radius is determined from the traditional extrapolation to q2 = 0. We will show that there is a model dependence in extracting the charge radius of hydrogen and its unambiguous determination is very difficult with available electron-scattering measurements.

  4. Radiation containment at a 1 MW high energy electron accelerator: Status of LCLS-II radiation physics design

    Science.gov (United States)

    Leitner, M. Santana; Blaha, J.; Guetg, M. W.; Li, Z.; Liu, J. C.; Mao, S. X.; Nicolas, L.; Rokni, S. H.; Xiao, S.; Ge, L.

    2017-09-01

    LCLS-II will add a 4 GeV, 1 MHz, SCRF electron accelerator in the first 700 meters of the SLAC 2-mile Linac, as well as adjustable gap polarized undulators in the down-beam electron lines, to produce tunable, fully coherent X-rays in programmable bunch patterns. This facility will work in unison with the existing Linac Coherent Light Source, which uses the legacy copper cavities in the last third of the linac to deliver electrons between 2 and 17 GeV to an undulator line. The upgrade plan includes new beam lines, five stages of state of the art collimation that shall clean the high-power beam well up-beam of the radio-sensitive undulators, and new electron and photon beam dumps. This paper describes the challenges encountered to define efficient measures to protect machine, personnel, public and the environment from the potentially destructive power of the beam, while maximizing the reuse of existing components and infrastructure, and allowing for complex operational modes.

  5. Radiation containment at a 1 MW high energy electron accelerator: Status of LCLS-II radiation physics design

    Directory of Open Access Journals (Sweden)

    Leitner M. Santana

    2017-01-01

    Full Text Available LCLS-II will add a 4 GeV, 1 MHz, SCRF electron accelerator in the first 700 meters of the SLAC 2-mile Linac, as well as adjustable gap polarized undulators in the down-beam electron lines, to produce tunable, fully coherent X-rays in programmable bunch patterns. This facility will work in unison with the existing Linac Coherent Light Source, which uses the legacy copper cavities in the last third of the linac to deliver electrons between 2 and 17 GeV to an undulator line. The upgrade plan includes new beam lines, five stages of state of the art collimation that shall clean the high-power beam well up-beam of the radio-sensitive undulators, and new electron and photon beam dumps. This paper describes the challenges encountered to define efficient measures to protect machine, personnel, public and the environment from the potentially destructive power of the beam, while maximizing the reuse of existing components and infrastructure, and allowing for complex operational modes.

  6. High-energy-resolution monochromator for aberration-corrected scanning transmission electron microscopy/electron energy-loss spectroscopy.

    Science.gov (United States)

    Krivanek, Ondrej L; Ursin, Jonathan P; Bacon, Neil J; Corbin, George J; Dellby, Niklas; Hrncirik, Petr; Murfitt, Matthew F; Own, Christopher S; Szilagyi, Zoltan S

    2009-09-28

    An all-magnetic monochromator/spectrometer system for sub-30 meV energy-resolution electron energy-loss spectroscopy in the scanning transmission electron microscope is described. It will link the energy being selected by the monochromator to the energy being analysed by the spectrometer, without resorting to decelerating the electron beam. This will allow it to attain spectral energy stability comparable to systems using monochromators and spectrometers that are raised to near the high voltage of the instrument. It will also be able to correct the chromatic aberration of the probe-forming column. It should be able to provide variable energy resolution down to approximately 10 meV and spatial resolution less than 1 A.

  7. High energy gain of trapped electrons in a tapered, diffraction-dominated inverse-free-electron laser.

    Science.gov (United States)

    Musumeci, P; Tochitsky, S Ya; Boucher, S; Clayton, C E; Doyuran, A; England, R J; Joshi, C; Pellegrini, C; Ralph, J E; Rosenzweig, J B; Sung, C; Tolmachev, S; Travish, G; Varfolomeev, A A; Varfolomeev, A A; Yarovoi, T; Yoder, R B

    2005-04-22

    Energy gain of trapped electrons in excess of 20 MeV has been demonstrated in an inverse-free-electron-laser (IFEL) accelerator experiment. A 14.5 MeV electron beam is copropagated with a 400 GW CO2 laser beam in a 50 cm long undulator strongly tapered in period and field amplitude. The Rayleigh range of the laser, approximately 1.8 cm, is much shorter than the undulator length yielding a diffraction-dominated interaction. Experimental results on the dependence of the acceleration on injection energy, laser focus position, and laser power are discussed. Simulations, in good agreement with the experimental data, show that most of the energy gain occurs in the first half of the undulator at a gradient of 70 MeV/m and that the structure in the measured energy spectrum arises because of higher harmonic IFEL interaction in the second half of the undulator.

  8. High Energy Gain of Trapped Electrons in a Tapered, Diffraction-Dominated Inverse-Free-Electron Laser

    Science.gov (United States)

    Musumeci, P.; Tochitsky, S. Ya.; Boucher, S.; Clayton, C. E.; Doyuran, A.; England, R. J.; Joshi, C.; Pellegrini, C.; Ralph, J. E.; Rosenzweig, J. B.; Sung, C.; Tolmachev, S.; Travish, G.; Varfolomeev, A. A.; Varfolomeev, A. A.; Yarovoi, T.; Yoder, R. B.

    2005-04-01

    Energy gain of trapped electrons in excess of 20 MeV has been demonstrated in an inverse-free-electron-laser (IFEL) accelerator experiment. A 14.5 MeV electron beam is copropagated with a 400 GW CO2 laser beam in a 50 cm long undulator strongly tapered in period and field amplitude. The Rayleigh range of the laser, ˜1.8 cm, is much shorter than the undulator length yielding a diffraction-dominated interaction. Experimental results on the dependence of the acceleration on injection energy, laser focus position, and laser power are discussed. Simulations, in good agreement with the experimental data, show that most of the energy gain occurs in the first half of the undulator at a gradient of 70 MeV/m and that the structure in the measured energy spectrum arises because of higher harmonic IFEL interaction in the second half of the undulator.

  9. Electron and photon energy measurement calibration with the ATLAS detector

    CERN Document Server

    Manzoni, Stefano; The ATLAS collaboration

    2016-01-01

    An accurate calibration of the energy measurement of electron and photon is paramount for many ATLAS physics analysis. The calibration of the energy measurement is performed in-situ using a large statistics of Z->ee events. The results obtained with the pp collisions data recorded in 2015 and 2016 at sqrt(s)= 13 TeV, corresponding to an integrated luminosity of 3.2 fb-1 and 2.7 fb-1 respectively , as well as the corresponding uncertainties on the electron and photon energy scales, are presented.

  10. Electron and photon energy measurement calibration with the ATLAS detector

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00436885; The ATLAS collaboration

    2016-01-01

    An accurate calibration of the energy measurement of electrons and photons is paramount for many ATLAS physics analyses. The calibration of the energy measurement is performed $in$-$situ$ using a large statistics of $Z \\rightarrow ee$ events. The results obtained with the $pp$ collisions data recorded in 2015 and 2016 at $\\sqrt{s}=13$ TeV, corresponding to an integrated luminosity of 3.2 fb$^{-1}$ and 2.7 fb$^{-1}$ respectively, as well as the corresponding uncertainties on the electron and photon energy scales, are presented

  11. An Electron/Photon/Relaxation Data Library for MCNP6

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, III, H. Grady [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-08-07

    The capabilities of the MCNP6 Monte Carlo code in simulation of electron transport, photon transport, and atomic relaxation have recently been significantly expanded. The enhancements include not only the extension of existing data and methods to lower energies, but also the introduction of new categories of data and methods. Support of these new capabilities has required major additions to and redesign of the associated data tables. In this paper we present the first complete documentation of the contents and format of the new electron-photon-relaxation data library now available with the initial production release of MCNP6.

  12. Unfolding the band structure of electronic and photonic materials

    Science.gov (United States)

    Maspero, Ross

    In this thesis, we develop a generalised unfolding formalism to investigate the electronic and photonic properties of aperiodically-structured materials. We initially focus on GaAsBi alloys for electronic systems and Penrose-structured materials for photonic systems, aperiodic materials that cannot be easily studied using conventional band structure methods. We then extend our study to the supercell approach which facilitates an accurate modelling of the aperiodic structures at the price of obscuring essential physical information, due to a band folding effect. Then introducing a generalised unfolding algorithm, we return the supercell band structure to a traditional form that can again be used to analyse the electronic and photonic properties of the system. GaAsBi, which is a material with the potential to suppress the dominant loss mechanisms in telecommunications devices, was studied using the unfolded supercell band structure approach. We investigated the effect of bismuth on the properties of a host GaAs structure, including band movement, band broadening and effective mass. We validated our approach through a detailed comparison of both band movement and effective masses to the currently available experimental data. Then, we introduced a formalism for calculating the CHSH Auger recombination rates from our unfolded band structure, which will assist in determining the efficiency of the material. Quasicrystalline photonic materials built on the skeleton of Penrose lattices have proven to display photonic properties comparable to the ones found in photonic crystals, but with the added promise of increased isotropy. The photonic band structure of these materials is a prime target for the unfolding formalism because it allows a full exploration of the influence of the increased geometrical symmetry on their photonic characteristics. Furthermore, the network structure investigated demonstrated the existence of a sub-fundamental photonic band gap, a characteristic

  13. Simultaneous optimization of photons and electrons for mixed beam radiotherapy

    Science.gov (United States)

    Mueller, S.; Fix, M. K.; Joosten, A.; Henzen, D.; Frei, D.; Volken, W.; Kueng, R.; Aebersold, D. M.; Stampanoni, M. F. M.; Manser, P.

    2017-07-01

    The aim of this work is to develop and investigate an inverse treatment planning process (TPP) for mixed beam radiotherapy (MBRT) capable of performing simultaneous optimization of photon and electron apertures. A simulated annealing based direct aperture optimization (DAO) is implemented to perform simultaneous optimization of photon and electron apertures, both shaped with the photon multileaf collimator (pMLC). Validated beam models are used as input for Monte Carlo dose calculations. Consideration of photon pMLC transmission during DAO and a weight re-optimization of the apertures after deliverable dose calculation are utilized to efficiently reduce the differences between optimized and deliverable dose distributions. The TPP for MBRT is evaluated for an academic situation with a superficial and an enlarged PTV in the depth, a left chest wall case including the internal mammary chain and a squamous cell carcinoma case. Deliverable dose distributions of MBRT plans are compared to those of modulated electron radiotherapy (MERT), photon IMRT and if available to those of clinical VMAT plans. The generated MBRT plans dosimetrically outperform the MERT, photon IMRT and VMAT plans for all investigated situations. For the clinical cases of the left chest wall and the squamous cell carcinoma, the MBRT plans cover the PTV similarly or more homogeneously than the VMAT plans, while OARs are spared considerably better with average reductions of the mean dose to parallel OARs and D 2% to serial OARs by 54% and 26%, respectively. Moreover, the low dose bath expressed as V 10% to normal tissue is substantially reduced by up to 45% compared to the VMAT plans. A TPP for MBRT including simultaneous optimization is successfully implemented and the dosimetric superiority of MBRT plans over MERT, photon IMRT and VMAT plans is demonstrated for academic and clinical situations including superficial targets with and without deep-seated part.

  14. Maximal Entanglement in High Energy Physics

    Directory of Open Access Journals (Sweden)

    Alba Cervera-Lierta, José I. Latorre, Juan Rojo, Luca Rottoli

    2017-11-01

    Full Text Available We analyze how maximal entanglement is generated at the fundamental level in QED by studying correlations between helicity states in tree-level scattering processes at high energy. We demonstrate that two mechanisms for the generation of maximal entanglement are at work: i $s$-channel processes where the virtual photon carries equal overlaps of the helicities of the final state particles, and ii the indistinguishable superposition between $t$- and $u$-channels. We then study whether requiring maximal entanglement constrains the coupling structure of QED and the weak interactions. In the case of photon-electron interactions unconstrained by gauge symmetry, we show how this requirement allows reproducing QED. For $Z$-mediated weak scattering, the maximal entanglement principle leads to non-trivial predictions for the value of the weak mixing angle $\\theta_W$. Our results are a first step towards understanding the connections between maximal entanglement and the fundamental symmetries of high-energy physics.

  15. Single Microwave Photon Detection with a Trapped Electron

    Directory of Open Access Journals (Sweden)

    April Cridland

    2016-11-01

    Full Text Available We investigate theoretically the use of an electron in a Penning trap as a detector of single microwave photons. At the University of Sussex we are developing a chip Penning trap technology, designed to be integrated within quantum circuits. Microwave photons are guided into the trap and interact with the electron’s quantum cyclotron motion. This is an electric dipole transition, where the near field of the microwave radiation induces quantum jumps of the cyclotron harmonic oscillator. The quantum jumps can be monitored using the continuous Stern-Gerlach effect, providing the quantum non demolition signal of the microwave quanta. We calculate the quantum efficiency of photon detection and discuss the main features and technical challenges for the trapped electron as a quantum microwave sensor.

  16. A new method of testing space-based high-energy electron detectors with radioactive electron sources

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, S.Y. [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Shen, G.H., E-mail: shgh@nssc.ac.cn [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Sun, Y., E-mail: sunying@nssc.ac.cn [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Zhou, D.Z., E-mail: dazhuang.zhou@gmail.com [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Zhang, X.X., E-mail: xxzhang@cma.gov.cn [National Center for Space Weather, Beijing (China); Li, J.W., E-mail: lijw@cma.gov.cn [National Center for Space Weather, Beijing (China); Huang, C., E-mail: huangc@cma.gov.cn [National Center for Space Weather, Beijing (China); Zhang, X.G., E-mail: zhangxg@nssc.ac.cn [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Dong, Y.J., E-mail: dyj@nssc.ac.cn [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Zhang, W.J., E-mail: zhangreatest@163.com [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Zhang, B.Q., E-mail: zhangbinquan@nssc.ac.cn [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Shi, C.Y., E-mail: scy@nssc.ac.cn [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China)

    2016-05-01

    Space-based electron detectors are commonly tested using radioactive β-sources which emit a continuous spectrum without spectral lines. Therefore, the tests are often to be considered only qualitative. This paper introduces a method, which results in more than a qualitative test even when using a β-source. The basic idea is to use the simulated response function of the instrument to invert the measured spectrum and compare this inverted spectrum with a reference spectrum obtained from the same source. Here we have used Geant4 to simulate the instrument response function (IRF) and a 3.5 mm thick Li-drifted Si detector to obtain the reference {sup 90}Sr/{sup 90}Yi source spectrum to test and verify the geometric factors of the Omni-Direction Particle Detector (ODPD) on the Tiangong-1 (TG-1) and Tiangong-2 (TG-2) spacecraft. The TG spacecraft are experimental space laboratories and prototypes of the Chinese space station. The excellent agreement between the measured and reference spectra demonstrates that this test method can be used to quantitatively assess the quality of the instrument. Due to its simplicity, the method is faster and therefore more efficient than traditional full calibrations using an electron accelerator.

  17. Convergence of Photonics and Electronics for Terahertz Wireless Communications

    DEFF Research Database (Denmark)

    Salazar, Adrian Ruiz; Rommel, Simon; Anufriyev, E.

    2016-01-01

    Terahertz wireless communications are expected to offer the required high capacity and low latency performance necessary for short-range wireless access and control applications. We present an overview of some the activities in this area in the newly started H2020 ITN project CELTA: Convergence...... of Electronics and Photonics Technologies Enabling Terahertz Applications....

  18. Raman scattering of photons by the channeling electrons

    Science.gov (United States)

    Badreeva, D. R.; Kalashnikov, N. P.

    2017-07-01

    The motion of channeling particles in the accompanying coordinate system can be considered as a two-dimensional atom in the case of axial channeling. The transversal motion of the channeling particles is characterized by discrete spectrum. The occupation probability of the transversal motion levels depends on the entrance angle of the charged particles relative to the crystallographic axis. In the scattering of a photon by the ;quasi-bound; electron moving in the axial channeling regime would appear the frequencies ω which are a combination of the incident photon frequency ω0 and the frequency ωNM (ωNM is the transition frequency in transverse quantized motion of the channeling electron: ω =ω0 ±ωMN , where ℏωMN = 2γ2 ΔE⊥NM for the relativistic electron, γ2 = E / (mc2) is the Lorentz factor of the channeling electron). In the article are discussed the criteria for choosing an adequate continuous potential of the crystallographic axis and the quantum characteristics of a transversal motion of the channeling electron. The peculiarities of the Raman scattering spectrum of photons by electrons in the axial channeling regime are analyzed and the differential cross section of this process is found.

  19. Modeling and simulation of longitudinal dynamics for Low Energy Ring–High Energy Ring at the Positron-Electron Project

    Directory of Open Access Journals (Sweden)

    C. Rivetta

    2007-02-01

    Full Text Available A time domain dynamic modeling and simulation tool for beam-cavity interactions in the Low Energy Ring (LER and High Energy Ring (HER at the Positron-Electron Project (PEP-II is presented. Dynamic simulation results for PEP-II are compared to measurements of the actual machine. The motivation for this tool is to explore the stability margins and performance limits of PEP-II radio-frequency (RF systems at future higher currents and upgraded RF configurations. It also serves as a test bed for new control algorithms and can define the ultimate limits of the low-level RF (LLRF architecture. The time domain program captures the dynamic behavior of the beam-cavity-LLRF interaction based on a reduced model. The ring current is represented by macrobunches. Multiple RF stations in the ring are represented via one or two macrocavities. Each macrocavity captures the overall behavior of all the 2 or 4 cavity RF stations. Station models include nonlinear elements in the klystron and signal processing. This enables modeling the principal longitudinal impedance control loops interacting via the longitudinal beam model. The dynamics of the simulation model are validated by comparing the measured growth rates for the LER with simulation results. The simulated behavior of the LER at increased operation currents is presented via low-mode instability growth rates. Different control strategies are compared and the effects of both the imperfections in the LLRF signal processing and the nonlinear drivers and klystrons are explored.

  20. Modeling and Simulation of Longitudinal Dynamics for Low Energy Ring_High Energy Ring at the Positron-Electron Project

    Energy Technology Data Exchange (ETDEWEB)

    Rivetta, Claudio; Mastorides, T.; Fox, J.D.; Teytelman, D.; Van Winkle, D.; /SLAC

    2007-03-06

    A time domain dynamic modeling and simulation tool for beam-cavity interactions in the Low Energy Ring (LER) and High Energy Ring (HER) at the Positron-Electron Project (PEP-II) is presented. Dynamic simulation results for PEP-II are compared to measurements of the actual machine. The motivation for this tool is to explore the stability margins and performance limits of PEP-II radio-frequency (RF) systems at future higher currents and upgraded RF configurations. It also serves as a test bed for new control algorithms and can define the ultimate limits of the low-level RF (LLRF) architecture. The time domain program captures the dynamic behavior of the beam-cavity-LLRF interaction based on a reduced model. The ring current is represented by macrobunches. Multiple RF stations in the ring are represented via one or two macrocavities. Each macrocavity captures the overall behavior of all the 2 or 4 cavity RF stations. Station models include nonlinear elements in the klystron and signal processing. This enables modeling the principal longitudinal impedance control loops interacting via the longitudinal beam model. The dynamics of the simulation model are validated by comparing the measured growth rates for the LER with simulation results. The simulated behavior of the LER at increased operation currents is presented via low-mode instability growth rates. Different control strategies are compared and the effects of both the imperfections in the LLRF signal processing and the nonlinear drivers and klystrons are explored.

  1. Theoretical Studies of Possible Synthetic Routes for the High Energy Density Material Td N4: Excited Electronic States

    Science.gov (United States)

    Lee, Timothy J.; Dateo, Christopher E.

    2001-01-01

    Vertical electronic excitation energies for single states have been computed for the high energy density material (HEDM) Td N4 in order to assess possible synthetic routes that originate from excited electronic states of N2 molecules. Several ab initio theoretical approaches have been used, including complete active space self-consistent field (CASSCF), state averaged CASSCF (SA-CASSCF), singles configuration interaction (CIS), CIS with second-order and third-order correlation corrections [CIS(D)) and CIS(3)], and linear response singles and doubles coupled-cluster (LRCCSD), which is the highest level of theory employed. Standard double zeta polarized (DZP) and triple zeta double polarized (TZ2P) one-particle basis sets were used. The CASSCF calculations are found to overestimate the excitation energies, while the SA-CASSCF approach rectifies this error to some extent, but not completely. The accuracy of the CIS calculations varied depending on the particular state, while the CIS(D), CIS(3), and LRCCSD results are in generally good agreement. Based on the LRCCSD calculations, the lowest six excited singlet states are 9.35(l(sup)T1), 10.01(l(sup)T2), 10.04(1(sup)A2), 10.07(1(sup)E), 10.12(2(sup)T1), and 10.42(2(sup)T2) eV above the ground state, respectively. Comparison of these excited state energies with the energies of possible excited states of N2+N2 fragments, leads us to propose that the most likely synthetic route for Td N4 involving this mechanism arises from combination of two bound quintet states of N2.

  2. Study of unexplained hard photon production by electrons channelled in a crystal

    CERN Multimedia

    2002-01-01

    Our preceding experiment (NA33) designed to study the pair creation process in the interaction of high energy $\\gamma$ with a crystal in alignment conditions had revealed the existence of an unexpected peak in the radiation of 150 GeV e$^{-}$ beam for E$_{\\gamma}$/E$_{e^{-}} \\simeq$ 0.85 incident along the axis of a 185 $\\mu$m. Ge crystal and the photon multiplicity for the peak events has been measured to be M $\\simeq$ 5.7.\\\\ In NA42, in a 76 $\\mu$m crystal of the same crystallographic quality, the peak nearly disappears, and the photon multiplicity at x = 0.85 is only M $\\simeq$ 2.0. \\\\ The thickness dependence of the effect shows that the extrapolated multiplicity in the peak in a very thin crystal tends to unity. The high energy radiation peak emitted by axially channeled electrons in a thick crystal is then interpreted by the radiation cooling mechanism. \\\\ The extrapolation to zero thickness of these results will allow us to extract from the data the single $\\gamma$ radiation spectrum. The comparison o...

  3. Structural dynamics of electronic and photonic systems

    CERN Document Server

    Suhir, Ephraim; Steinberg, David S

    2011-01-01

    The proposed book will offer comprehensive and versatile methodologies and recommendations on how to determine dynamic characteristics of typical micro- and opto-electronic structural elements (printed circuit boards, solder joints, heavy devices, etc.) and how to design a viable and reliable structure that would be able to withstand high-level dynamic loading. Particular attention will be given to portable devices and systems designed for operation in harsh environments (such as automotive, aerospace, military, etc.)  In-depth discussion from a mechanical engineer's viewpoint will be conducte

  4. ENERGETIC PHOTON AND ELECTRON INTERACTIONS WITH POSITIVE IONS

    Energy Technology Data Exchange (ETDEWEB)

    Phaneuf, Ronald A. [UNR

    2013-07-01

    The objective of this research is a deeper understanding of the complex multi-electron interactions that govern inelastic processes involving positive ions in plasma environments, such as those occurring in stellar cares and atmospheres, x-ray lasers, thermonuclear fusion reactors and materials-processing discharges. In addition to precision data on ionic structure and transition probabilities, high resolution quantitative measurements of ionization test the theoretical methods that provide critical input to computer codes used for plasma modeling and photon opacity calculations. Steadily increasing computational power and a corresponding emphasis on simulations gives heightened relevance to precise and accurate benchmark data. Photons provide a highly selective probe of the internal electronic structure of atomic and molecular systems, and a powerful means to better understand more complex electron-ion interactions.

  5. Electron, photons, and molecules: Storing energy from light

    Energy Technology Data Exchange (ETDEWEB)

    Miller, J.R. [Argonne National Laboratory, IL (United States)

    1996-09-01

    Molecular charge separation has important potential for photochemical energy storage. Its efficiency can be enhanced by principals which maximize the rates of the electron transfer steps which separate charge and minimize those which recombine high-energy charge pairs to lose stored energy. Dramatic scientific progress in understanding these principals has occurred since the founding of DOE and its predecessor agency ERDA. While additional knowledge in needed in broad areas of molecular electron transfer, some key areas of knowledge hold particular promise for the possibility of moving this area from science toward technology capable of contributing to the nation`s energy economy.

  6. The Pierre Auger observatory's project of detecting photons and neutrinos at very high energies; L'observatoire Pierre Auger vers la detection de photons et neutrinos a ultra haute energies?

    Energy Technology Data Exchange (ETDEWEB)

    Bertou, X

    2001-11-01

    Cosmic radiations of ultra high energy (RCUHE, beyond 10{sup 18} eV) are difficult to study because of their low flux on the earth surface: about 1 photon per year and per km{sup 2}. The observatory Pierre Auger proposes to study RCUHE by designing 2 sites of 3000 km{sup 2} (one in each hemisphere) allowing the observation of the shower initiated by cosmic radiation by using 4 fluorescence telescopes and a network of 1600 Cherenkov detectors. The identification of the primary particle is a very delicate point, the detection of neutrino or photon at these energies would bring valuable information for the understanding of potential sources of RCUHE. The first part of this work presents the project and its assets to perform its task. The second part is dedicated to the description of the Cherenkov detectors, of the trigger system, and of the centralized data acquisition system. The last part present the prototype installation that is under construction at Macargue in Argentina. (A.C.)

  7. Photonics and Web Engineering 2011, International Journal of Electronics and Telecommunication, vol.57, no 3, pp.421-428, September 2011

    CERN Document Server

    Romaniuk, R S

    2011-01-01

    The paper presents a digest of chosen technical work results shown by young researchers from different technical universities in this country during the SPIE-IEEE Wilga 2011 symposium on Photonics and Web Engineering. Topical tracks of the symposium embraced, among others, nanomaterials and nanotechnologies for photonics and telecom, sensory and nonlinear optical fibers, object oriented design of hardware, photonic metrology, optoelectronics and photonics applications, photonicselectronics co-design, optoelectronic and electronic systems for telecom, astronomy and high energy physics experiments, JET and pi-of-the sky experiments development. The symposium is an annual summary in the development of numerable Ph.D. theses carried out in this country in the area of advanced electronic and photonic systems. It is also an occasion for young researchers to meet together in a large group (under the patronage of IEEE) spanning the whole country with guests from this part of Europe. A digest of Wilga references is pr...

  8. Photoproduction at high energy and high intensity

    CERN Multimedia

    2002-01-01

    The photon beam used for this programme is tagged and provides a large flux up to very high energies (150-200 GeV). It is also hadron-free, since it is obtained by a two-step conversion method. A spectrometer is designed to exploit this beam and to perform a programme of photoproduction with a high level of sensitivity (5-50 events/picobarn).\\\\ \\\\ Priority will be given to the study of processes exhibiting the point-like behaviour of the photon, especially deep inelastic Compton scattering. The spectrometer has two magnets. Charged tracks are measured by MWPC's located only in field-free regions. Three calorimeters provide a large coverage for identifying and measuring electrons and photons. An iron filter downstream identifies muons. Most of the equipment is existing and recuperated from previous experiments.

  9. Multi-photon creation and single-photon annihilation of electron-positron pairs

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Huayu

    2011-04-27

    In this thesis we study multi-photon e{sup +}e{sup -} pair production in a trident process, and singlephoton e{sup +}e{sup -} pair annihilation in a triple interaction. The pair production is considered in the collision of a relativistic electron with a strong laser beam, and calculated within the theory of laser-dressed quantum electrodynamics. A regularization method is developed systematically for the resonance problem arising in the multi-photon process. Total production rates, positron spectra, and relative contributions of different reaction channels are obtained in various interaction regimes. Our calculation shows good agreement with existing experimental data from SLAC, and adds further insights into the experimental findings. Besides, we study the process in a manifestly nonperturbative domain, whose accessibility to future all-optical experiments based on laser acceleration is shown. In the single-photon e{sup +}e{sup -} pair annihilation, the recoil momentum is absorbed by a spectator particle. Various kinematic configurations of the three incoming particles are examined. Under certain conditions, the emitted photon exhibits distinct angular and polarization distributions which could facilitate the detection of the process. Considering an equilibrium relativistic e{sup +}e{sup -} plasma, it is found that the single-photon process becomes the dominant annihilation channel for plasma temperatures above 3 MeV. Multi-particle correlation effects are therefore essential for the e{sup +}e{sup -} dynamics at very high density. (orig.)

  10. Search for new physics in final states with a high energy electron and large missing transverse energy

    Energy Technology Data Exchange (ETDEWEB)

    Schuh, Natascha

    2017-01-13

    The most successful and comprehensive theory describing the microcosm is the Standard Model of particle physics (SM). It comprises all known elementary particles and describes in high precision the basic processes of three of the four fundamental interactions. But still, not all experimental observations and theoretical challenges are covered. Many models exist that take the SM as a good approximation of natural phenomena in already discovered energy regions, but extend it in various ways. The Large Hadron Collider (LHC) provides the opportunity to look into these high energy regions using proton-proton collisions at significantly higher center-of-mass energies than previous experiments. This dissertation searches for physics beyond the SM especially in final states with one highly energetic electron (respectively positron) and large missing transverse energy. With the data set recorded in 2012 by the ATLAS detector, a large multi-purpose detector making use of the LHC, the spectrum of the related combined transverse mass can be measured up to the TeV scale. To find any evidence to the existence of new physics beyond the SM, it was searched for significant deviations between the observed data and the expectations due to SM processes. Unfortunately, no significant excess could be observed and exclusion limits in the context of three different new physics scenarios are provided. Besides a so-called Sequential Standard Model (SSM) predicting additional vector gauge bosons, also the possible existence of (charged) chiral bosons is analyzed. Also inferences about dark matter candidates called ''weakly interacting massive particles (WIMP)'' are drawn. With the aid of a Bayesian ansatz, the observed (expected) exclusion limit on the boson pole mass is set to 3.13 TeV(3.13 TeV) for a SSM W' boson and to 3.08 TeV(3.08 TeV) for charged chiral W{sup *} bosons (at 95% C.L.).

  11. High-energy detector

    Science.gov (United States)

    Bolotnikov, Aleksey E [South Setauket, NY; Camarda, Giuseppe [Farmingville, NY; Cui, Yonggang [Upton, NY; James, Ralph B [Ridge, NY

    2011-11-22

    The preferred embodiments are directed to a high-energy detector that is electrically shielded using an anode, a cathode, and a conducting shield to substantially reduce or eliminate electrically unshielded area. The anode and the cathode are disposed at opposite ends of the detector and the conducting shield substantially surrounds at least a portion of the longitudinal surface of the detector. The conducting shield extends longitudinally to the anode end of the detector and substantially surrounds at least a portion of the detector. Signals read from one or more of the anode, cathode, and conducting shield can be used to determine the number of electrons that are liberated as a result of high-energy particles impinge on the detector. A correction technique can be implemented to correct for liberated electron that become trapped to improve the energy resolution of the high-energy detectors disclosed herein.

  12. HIGH ENERGY ELECTRON INJECTION (E-BEAM) TECHNOLOGY FOR THE EX-SITU TREATMENT OF MTBE-CONTAMINATED GROUNDWATER INNOVATIVE TECHNOLOGY EVALUATION REPORT

    Science.gov (United States)

    This Innovative Technology Evaluation Report documents the results of a demonstration of the high-energy electron injection (E-Beam) technology in application to groundwater contaminated with methyl t-butyl ether (MtBE) and with benzene, toluene, ethylbenzene, and xylenes (BTEX)....

  13. Electron and photon energy calibration with the ATLAS detector

    CERN Document Server

    Falke, Saskia; The ATLAS collaboration

    2017-01-01

    An accurate calibration of the energy measurement of electron and photon is needed for many ATLAS physics analysis. The calibration of the energy measurement is performed in-situ using a large statistics of Z->ee events. A pre-requisite of this calibration is a good understanding of the material in front of the calorimeter and of the inter-calibration of the different calorimeter layers. The Z->ee sample is also used to measure the energy resolution. The results obtained with the pp collisions data at sqrt(s)=13 TeV in 2016 (2015) corresponding to an integrated luminosity of 33.9 (3.1)fb-1 of sqrt(s)=13 TeV are presented as well as the corresponding uncertainties on the electron and photon energy scales.

  14. Photon counting imaging with an electron-bombarded CCD: Towards wide-field time-correlated single photon counting (TCSPC)

    Energy Technology Data Exchange (ETDEWEB)

    Hirvonen, Liisa M.; Jiggins, Stephen; Sergent, Nicolas; Zanda, Gianmarco; Suhling, Klaus, E-mail: klaus.suhling@kcl.ac.uk

    2015-07-01

    Single photon detecting capabilities of an electron-bombarded CCD (EBCCD), where a photon is converted into a photoelectron that is accelerated through a high voltage before hitting the CCD chip, were characterised. The photon event pulse height distribution was found to be linearly dependent on the gain voltage. Based on these results, we propose that a gain voltage sweep during exposure in an EBCCD or EBCMOS camera would allow photon arrival time determination from the photon event pulse height with sub-frame exposure time resolution. This effectively uses an electron-bombarded sensor as a parallel-processing photoelectronic time-to-amplitude converter (TAC), or a 2-dimensional streak camera. Several applications that require timing of photon arrival, including fluorescence lifetime imaging microscopy (FLIM), may benefit from this approach. Moreover, the EBCCD was used on a fluorescence microscope to image fluorescently labelled cells in single photon counting mode.

  15. Scaling of cross sections for K-electron capture by high-energy protons and alpha-particles from the multielectron atoms

    Science.gov (United States)

    Omidvar, K.

    1979-01-01

    Electron capture by protons from H, He, and the K shell of Ar, and electron capture by alpha particles from He are considered. Using the experimental data, a function of the capture cross section is formed. It is shown that when this function is plotted versus the inverse of the collision energies, at high energies a straight line is obtained. At lower energies the line is concave up or down, depending on the charge of the projectile and/or the effective charge and the ionization potential of the electron that is being captured. The plot can be used to predict cross sections where experimental data are not available, and as a guide in future experiments. High-energy scaling formulas for K-electron capture by low-charge projectiles are given.

  16. High energy particle astronomy.

    Science.gov (United States)

    Buffington, A.; Muller, R. A.; Smith, L. H.; Smoot, G. F.

    1972-01-01

    Discussion of techniques currently used in high energy particle astronomy for measuring charged and neutral cosmic rays and their isotope and momentum distribution. Derived from methods developed for accelerator experiments in particle physics, these techniques help perform important particle astronomy experiments pertaining to nuclear cosmic ray and gamma ray research, electron and position probes, and antimatter searches.

  17. Creation of high energy bremsstrahlung and intensity by a multitarget and refocusing of the scattered electrons by small-angle backscatter at the wall of a cone and magnetic fields

    CERN Document Server

    Ulmer, W

    2011-01-01

    The yield of bremsstrahlung from collisions of fast electrons (energy at least 6 MeV) with a tungsten target can be significantly improved by exploitation of Tungsten wall scatter in a multi-layered target. The Tungsten wall can serve to refocuse small angle scattered electrons. It is necessary that the thickness of one Tungsten layer does not exceed 0.02 mm. Further refocusing of electrons results from suitable magnetic fields with field strength between 0.5 Tesla and 6 Tesla (if the cone with multi-layered targets is rather narrow). Linear accelerators in radiation therapy only need refocusing by wall scatter without further magnetic fields (standard case: ca. 100 - 000 plates with 0.01 mm thickness and 1 mm distance between the plates). The construction of a very narrow bremsstrahlung beam with extremely high photon intensity requires an additional strong magnetic field (order 1 - 6 Tesla), which provides the possibility to check Heisenberg-Euler scatter of high energy photons.

  18. High energy astrophysical techniques

    CERN Document Server

    Poggiani, Rosa

    2017-01-01

    This textbook presents ultraviolet and X-ray astronomy, gamma-ray astronomy, cosmic ray astronomy, neutrino astronomy, and gravitational wave astronomy as distinct research areas, focusing on the astrophysics targets and the requirements with respect to instrumentation and observation methods. The purpose of the book is to bridge the gap between the reference books and the specialized literature. For each type of astronomy, the discussion proceeds from the orders of magnitude for observable quantities. The physical principles of photon and particle detectors are then addressed, and the specific telescopes and combinations of detectors, presented. Finally the instruments and their limits are discussed with a view to assisting readers in the planning and execution of observations. Astronomical observations with high-energy photons and particles represent the newest additions to multimessenger astronomy and this book will be of value to all with an interest in the field.

  19. MO-H-19A-01: FEATURED PRESENTATION - Treatment Planning Tool for Radiotherapy with Very High-Energy Electron Beams

    Energy Technology Data Exchange (ETDEWEB)

    Bazalova, M; Qu, B; Palma, B; Loo, B; Maxim, P [Stanford University, Stanford, CA (United States); Hynning, E; Hardemark, B [RaySearch Laboratories, Stockholm (Sweden)

    2014-06-15

    Purpose: To develop a tool for treatment planning optimization for fast radiotherapy delivered with very high-energy electron beams (VHEE) and to compare VHEE plans to state-of-the-art plans for challenging pelvis and H'N cases. Methods: Treatment planning for radiotherapy delivered with VHEE scanning pencil beams was performed by integrating EGSnrc Monte Carlo (MC) dose calculations with spot scanning optimization run in a research version of RayStation. A Matlab GUI for MC beamlet generation was developed, in which treatment parameters such as the pencil beam size and spacing, energy and number of beams can be selected. Treatment planning study for H'N and pelvis cases was performed and the effect of treatment parameters on the delivered dose distributions was evaluated and compared to the clinical treatment plans. The pelvis case with a 691cm3 PTV was treated with 2-arc 15MV VMAT and the H'N case with four PTVs with total volume of 531cm3 was treated with 4-arc 6MV VMAT. Results: Most studied VHEE plans outperformed VMAT plans. The best pelvis 80MeV VHEE plan with 25 beams resulted in 12% body dose sparing and 8% sparing to the bowel and right femur compared to the VMAT plan. The 100MeV plan was superior to the 150MeV plan. Mixing 100 and 150MeV improved dose sparing to the bladder by 7% compared to either plan. Plans with 16 and 36 beams did not significantly affect the dose distributions compared to 25 beam plans. The best H'N 100MeV VHEE plan decreased mean doses to the brainstem, chiasm, and both globes by 10-42% compared to the VMAT plan. Conclusion: The pelvis and H'N cases suggested that sixteen 100MeV beams might be sufficient specifications of a novel VHEE treatment machine. However, optimum machine parameters will be determined with the presented VHEE treatment-planning tool for a large number of clinical cases. BW Loo and P Maxim received research support from RaySearch Laboratories. E Hynning and B Hardemark are employees of

  20. Polymer ring resonators for high density photonic and electronic-photonic integration

    Science.gov (United States)

    Sun, Haishan

    2009-12-01

    Electrical interconnect based on the copper wires will be the bottleneck for the future performance improvement of multi-core CPUs. Chip scale optical interconnect based on high density photonic and electronic-photonic integration is one of the feasible solutions. Ring resonators are promising photonic components serving as building blocks. High density integration of ring resonators is also important for high throughput lab-on-a-chip biosensors and opto-microwave integrated circuits. Polymer materials are compatible with most semiconductor fabrication processes. Polymers can be easily doped with rare earth ions, quantum dots etc. to make active optical devices. Especially, over several hundreds pm/V electro-optic (EO) coefficients and femtosecond scale response time of EO polymers enables photonic devices with sub 1V to millivolt drive voltages and terahertz bandwidth. This dissertation describes several technologies about design, simulation, fabrication, integration with electronic circuits and fiber optics of polymer ring resonators, and demonstrates three application examples of polymer ring resonators in communications and biochemical sensing. First the Beam Propagation Method (BPM) and the matrix analysis are combined to provide a fast circuit level simulation and design procedure of polymer ring resonators. Several low cost fabrication techniques based on electron beam irradiation effects on EO polymers are introduced. For the practical electronicphotonic integration, a hybrid integration scheme of EO polymer waveguide devices with Si integrated circuits is developed. One application is an all-dielectric RF sensor or receiver with sensitivity of 100 V/m and theoretical bandwidth over 100 GHz. This device is based on a novel structure with polymer ring resonator directly coupled to a side polished optical fiber. The other two examples are biochemical sensors based on multi-slot waveguide and ring resonator reflector structures.

  1. Signatures of plasmoemission in two photon photoemission electron microscopy

    Science.gov (United States)

    Meyer zu Heringdorf, Frank-J.; Kahl, Philip; Makris, Andreas; Sindermann, Simon; Podbiel, Daniel; Horn-von Hoegen, Michael

    2015-03-01

    The imaging of surface plasmon polariton waves in two photon photoemission microscopy has been intensely studied during the past years, with a focus on contrast mechanisms and light-plasmon interaction. The possibility of photoemission from the plasmonic fields alone has so far not been addressed in such experiments. This was justified, since the intensity of the plasmonic fields at the surface was comparatively weak and nonlinear plasmonic effects were not to be expected. Here we discuss the properties of grating couplers for creation of intense and short plasmon polariton pulses for which the emission of electrons purely from the plasmonic field cannot be neglected any more. Two examples for signatures of such nonlinear plasmoemission effects in experimental two photon photoemission microscopy images are discussed.

  2. GEM applications outside high energy physics

    CERN Document Server

    Duarte Pinto, Serge

    2013-01-01

    From its invention in 1997, the Gas Electron Multiplier has been applied in nuclear and high energy physics experiments. Over time however, other applications have also exploited the favorable properties of GEMs. The use of GEMs in these applications will be explained in principle and practice. This paper reviews applications in research, beam instrumentation and homeland security. The detectors described measure neutral radiations such as photons, x-rays, gamma rays and neutrons, as well as all kinds of charged radiation. This paper provides an overview of the still expanding range of possibilities of this versatile detector concept.

  3. Development and characterization of high temperature, high energy density dielectric materials to establish routes towards power electronics capacitive devices

    Science.gov (United States)

    Shay, Dennis P.

    The maximum electrostatic energy density of a capacitor is a function of the relative permittivity (epsilonr) and the square of the dielectric breakdown strength (Eb). Currently, state-of-the art high temperature (>200 °C), SiC-based power electronics utilize CaZrO3-rich NP0/C0G-type capacitors, which have low relative permittivities of epsilonr ˜ 30-40, high breakdown strengths (> 1.0 MV/cm), and are chosen for their minimal change in energy storage with temperature. However, with operating temperatures exceeding the rated temperatures for such capacitors, there is an opportunity to develop new dielectric ceramics having higher energy densities and volumetric efficiencies at high temperatures (>200 °C) by utilizing higher permittivity dielectrics while maintaining high breakdown strengths via doping. The solid solution behavior of was characterized in order to determine the optimal composition for balancing permittivity and dielectric breakdown strength to obtain high energy densities at elevated temperatures. Characterization by X-ray diffraction (XRD) showed Vegard's law behavior across the solid solution with minimal 2nd phases. To determine a Ca(TixZr1-x)O3 composition that will also minimize electronic or band conduction, the optical properties of the Ca(TixZr1-x)O3 solid solution were investigated to identify a composition on the CaTiO3 - rich end of the solid solution with a large band gap. Both ultraviolet-visible diffuse reflectance spectroscopy (UV-Vis) and spectroscopic ellipsometry were utilized to determine the Ca(TixZr1-x)O3 band gaps and optical properties. The resistivity at 250 °C scaled with the band gap energy across the solid solution. Comparing the current-voltage (I--V) behavior at 250 °C for Ca(Tix-yMnyZr0.2)O3 (CTZ + Mn) where x = 0.7, 0.8, 0.9, and y = 0.005, it was found that the Ca(Ti 0.795Mn0.005Zr0.2)O3 composition showed the lowest current density and a decrease in current density of 5 orders of magnitude compared to the un

  4. Electronic/photonic interfaces for ultrafast data processing.

    Energy Technology Data Exchange (ETDEWEB)

    Overberg, Mark E.; Geib, Kent Martin; Serkland, Darwin Keith; Hsu, Alan Yuan-Chun; Keeler, Gordon Arthur; Finnegan, Patrick Sean (LMATA Government Services, LLC, Albuquerque, NM)

    2008-09-01

    This report summarizes a 3-month program that explored the potential areas of impact for electronic/photonic integration technologies, as applied to next-generation data processing systems operating within 100+ Gb/s optical networks. The study included a technology review that targeted three key functions of data processing systems, namely receive/demultiplexing/clock recovery, data processing, and transmit/multiplexing. Various technical approaches were described and evaluated. In addition, we initiated the development of high-speed photodetectors and hybrid integration processes, two key elements of an ultrafast data processor. Relevant experimental results are described herein.

  5. On thermalization of electron-positron-photon plasma

    Energy Technology Data Exchange (ETDEWEB)

    Siutsou, I. A., E-mail: siutsou@icranet.org [CAPES–ICRANet program, ICRANet–Rio, CBPF 22290-180, Rua Dr. Xavier Sigaud, 150, Urca, Rio de Janeiro, RJ (Brazil); Aksenov, A. G. [Institute for Computer-Aided Design, Russian Academy of Sciences 123056, 2nd Brestskaya st., 19/18, Moscow (Russian Federation); Vereshchagin, G. V. [ICRANet 65122, p.le della Republica, 10, Pescara (Italy)

    2015-12-17

    Recently a progress has been made in understanding thermalization mechanism of relativistic plasma starting from a non-equilibrium state. Relativistic Boltzmann equations were solved numerically for homogeneous isotropic plasma with collision integrals for two- and three-particle interactions calculated from the first principles by means of QED matrix elements. All particles were assumed to fulfill Boltzmann statistics. In this work we follow plasma thermalization by accounting for Bose enhancement and Pauli blocking in particle interactions. Our results show that particle in equilibrium reach Bose-Einstein distribution for photons, and Fermi-Dirac one for electrons, respectively.

  6. Wide Bandgap Semiconductor Nanowires for Electronic, Photonic and Sensing Devices

    Science.gov (United States)

    2012-01-05

    vapor deposition ( CVD ) using gold thin films as catalyst on a Si wafer with an insulating SiO2 layer. The structural characterization of the as-grown...advantages in improved carrier confinement over their thin film counterparts. The bandgap of the ZnO may be increased by addition of Mg. Results: We...variety of wide bandgap nanowires using GaN and ZnO and made functional devices from them for sensing,electronics and photonics.These included a very

  7. High Energy Particle Accelerators

    CERN Multimedia

    Audio Productions, Inc, New York

    1960-01-01

    Film about the different particle accelerators in the US. Nuclear research in the US has developed into a broad and well-balanced program.Tour of accelerator installations, accelerator development work now in progress and a number of typical experiments with high energy particles. Brookhaven, Cosmotron. Univ. Calif. Berkeley, Bevatron. Anti-proton experiment. Negative k meson experiment. Bubble chambers. A section on an electron accelerator. Projection of new accelerators. Princeton/Penn. build proton synchrotron. Argonne National Lab. Brookhaven, PS construction. Cambridge Electron Accelerator; Harvard/MIT. SLAC studying a linear accelerator. Other research at Madison, Wisconsin, Fixed Field Alternate Gradient Focusing. (FFAG) Oakridge, Tenn., cyclotron. Two-beam machine. Comments : Interesting overview of high energy particle accelerators installations in the US in these early years. .

  8. Development of an external readout electronics for a hybrid photon detector

    CERN Document Server

    Uyttenhove, Simon; Tichon, Jacques; Garcia, Salvador

    The pixel hybrid photon detectors currently installed in the LHCb Cherenkov system encapsulate readout electronics in the vacuum tube envelope. The LHCb upgrade and the new trigger system will require their replacement with new photon detectors. The baseline photon detector candidate is the multi-anode photomultiplier. A hybrid photon detector with external readout electronics has been proposed as a backup option. This master thesis covers a R & D phase to investigate this latter concept. Extensive studies of the initial electronics system underlined the noise contributions from the Beetle chip used as front-end readout ASIC and from the ceramic carrier of the photon detector. New front-end electronic boards have been developed and made fully compatible with the existing LHCb-RICH infrastructure. With this compact readout system, Cherenkov photons have been successfully detected in a real particle beam environment. The proof-of-concept of a hybrid photon detector with external readout electronics was val...

  9. Inexpensive electronics and software for photon statistics and correlation spectroscopy.

    Science.gov (United States)

    Gamari, Benjamin D; Zhang, Dianwen; Buckman, Richard E; Milas, Peker; Denker, John S; Chen, Hui; Li, Hongmin; Goldner, Lori S

    2014-07-01

    Single-molecule-sensitive microscopy and spectroscopy are transforming biophysics and materials science laboratories. Techniques such as fluorescence correlation spectroscopy (FCS) and single-molecule sensitive fluorescence resonance energy transfer (FRET) are now commonly available in research laboratories but are as yet infrequently available in teaching laboratories. We describe inexpensive electronics and open-source software that bridges this gap, making state-of-the-art research capabilities accessible to undergraduates interested in biophysics. We include a discussion of the intensity correlation function relevant to FCS and how it can be determined from photon arrival times. We demonstrate the system with a measurement of the hydrodynamic radius of a protein using FCS that is suitable for the undergraduate teaching laboratory. The FPGA-based electronics, which are easy to construct, are suitable for more advanced measurements as well, and several applications are described. As implemented, the system has 8 ns timing resolution, can control up to four laser sources, and can collect information from as many as four photon-counting detectors.

  10. New Results on High Energy Cosmic Ray Electrons Observed with Fermi LAT and Their Implications on the Origin of Cosmic Rays

    Science.gov (United States)

    Moiseev, Alexander

    2010-01-01

    The Large Area Telescope on-board the Fermi Gamma-Ray Space Telescope has collected more than 10 million cosmic ray electrons with energy above 7 GeV since its science operation on orbit. High energy electrons rapidly lose their energy by synchrotron radiation on Galactic magnetic fields and by inverse Compton scattering on the interstellar radiation field. The typical distance over which a 1 TeV electron loses half its total energy is estimated to be 300-400 pc.This makes them a unique tool for probing nearby Galactic space. Observed spectrum has a harder spectral index than was previously reported and suggests the presence of nearby sources of high energy electrons. One of viable candidates are nearby pulsars, possibly some of recently discovered by Fermi. At the same time the dark matter origin of such sources cannot be ruled out. I will also report our current upper limits on cosmic ray electrons anisotropy which helps to set constraints on their local sources.

  11. Accelerator Technology and High Energy Physic Experiments, WILGA 2012; EuCARD Sessions

    CERN Document Server

    Romaniuk, R S

    2012-01-01

    Wilga Sessions on HEP experiments, astroparticle physica and accelerator technology were organized under the umbrella of the EU FP7 Project EuCARD – European Coordination for Accelerator Research and Development. The paper is the second part (out of five) of the research survey of WILGA Symposium work, May 2012 Edition, concerned with accelerator technology and high energy physics experiments. It presents a digest of chosen technical work results shown by young researchers from different technical universities from this country during the XXXth Jubilee SPIE-IEEE Wilga 2012, May Edition, symposium on Photonics and Web Engineering. Topical tracks of the symposium embraced, among others, nanomaterials and nanotechnologies for photonics, sensory and nonlinear optical fibers, object oriented design of hardware, photonic metrology, optoelectronics and photonics applications, photonics-electronics co-design, optoelectronic and electronic systems for astronomy and high energy physics experiments, JET and pi-of-the ...

  12. Photon momentum sharing between an electron and an ion in photoionization: from one-photon (photoelectric effect) to multiphoton absorption.

    Science.gov (United States)

    Chelkowski, Szczepan; Bandrauk, André D; Corkum, Paul B

    2014-12-31

    We investigate photon-momentum sharing between an electron and an ion following different photoionization regimes. We find very different partitioning of the photon momentum in one-photon ionization (the photoelectric effect) as compared to multiphoton processes. In the photoelectric effect, the electron acquires a momentum that is much greater than the single photon momentum ℏω/c [up to (8/5) ℏω/c] whereas in the strong-field ionization regime, the photoelectron only acquires the momentum corresponding to the photons absorbed above the field-free ionization threshold plus a momentum corresponding to a fraction (3/10) of the ionization potential Ip. In both cases, due to the smallness of the electron-ion mass ratio, the ion takes nearly the entire momentum of all absorbed N photons (via the electron-ion center of mass). Additionally, the ion takes, as a recoil, the photoelectron momentum resulting from mutual electron-ion interaction in the electromagnetic field. Consequently, the momentum partitioning of the photofragments is very different in both regimes. This suggests that there is a rich, unexplored physics to be studied between these two limits which can be generated with current ultrafast laser technology.

  13. Radiation containment at a 1 MW high energy electron accelerator: Status of LCLS-II radiation physics design

    National Research Council Canada - National Science Library

    M Santana Leitner; J Blaha; MW Guetg; Z Li; JC Liu; SX Mao; L Nicolas; SH Rokni; S Xiao; L Ge

    2017-01-01

    LCLS-II will add a 4 GeV, 1 MHz, SCRF electron accelerator in the first 700 meters of the SLAC 2-mile Linac, as well as adjustable gap polarized undulators in the down-beam electron lines, to produce...

  14. Formation of the sodium 1-D structures in doped NaCl by high energy electron irradiation

    NARCIS (Netherlands)

    Cherkasov, FG; Mustafin, RG; L'vov, SG; Khaibullin, RI; den Hartog, HW; Vainshtein, DI; Vitol, AY; L’vov, S.G.

    1998-01-01

    An investigation of the formation and properties of linear sodium structures in electron-irradiated potassium doped NaCl crystals was carried out by means of electron spin resonance (ESR) and nuclear magnetic resonance (NMR). It has been found that the behavior of ESR and NMR signals depends on the

  15. Ultrafast terahertz electrodynamics of photonic and electronic nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Liang [Iowa State Univ., Ames, IA (United States)

    2015-01-01

    This thesis summarizes my work on using ultrafast laser pulses to study Terahertz (THz) electrodynamics of photonic and electronic nanostructures and microstructures. Ultrafast timeresolved (optical, NIR, MIR, THz) pump-probe spectroscopy setup has been successfully built, which enables me to perform a series of relevant experiments. Firstly, a novel high e ciency and compact THz wave emitter based on split-ring-resonators has been developed and characterized. The emitter can be pumped at any wavelength by tailoring the magnetic resonance and could generate gapless THz waves covering the entire THz band. Secondly, two kinds of new photonic structures for THz wave manipulation have been successfully designed and characterized. One is based on the 1D and 2D photo-imprinted di ractive elements. The other is based on the photoexcited double-split-ring-resonator metamaterials. Both structures are exible and can modulate THz waves with large tunability. Thirdly, the dark excitons in semiconducting singlewalled carbon nanotubes are studied by optical pump and THz probe spectroscopy, which provides the rst insights into the THz responses of nonequilibrium excitonic correlations and dynamics from the dark ground states in carbon nanotubes. Next, several on-going projects are brie y presented such as the study of ultrafast THz dynamics of Dirac fermions in topological insulator Bi2Se3 with Mid-infrared excitation. Finally, the thesis ends with a summary of the completed experiments and an outlook of the future plan.

  16. Study of High Energy Positron Annihilation in GEANT4

    CERN Document Server

    Chikuma, Naruhiro

    2014-01-01

    A high energy positron may annihilate with an electron in atoms not only into two photons, but also into muon pairs or hadrons if the energy is over the energy threshold, 43.69 GeV in laboratory frame with electrons at rest. This report shows modication of high energy electromagnetic processes in GEANT4(version 10.01.b01) in order to include these annihilation processes properly, validation of GEANT4 cross-sections of these processes by theoretical calculation, and the results of simulation for high energy processes in a simple setup. As a results of simulation, both of annihilation to muon pairs and to hadrons happen by the probability of 10-6 to 10-5.

  17. Radiation containment at a 1 MW high energy electron accelerator: Status of LCLS-II radiation physics design

    OpenAIRE

    Leitner M. Santana; Blaha J.; Guetg M.W.; Li Z; Liu J.C.; Mao S.X.; Nicolas L; Rokni S.H.; Xiao S.; Ge L

    2017-01-01

    LCLS-II will add a 4 GeV, 1 MHz, SCRF electron accelerator in the first 700 meters of the SLAC 2-mile Linac, as well as adjustable gap polarized undulators in the down-beam electron lines, to produce tunable, fully coherent X-rays in programmable bunch patterns. This facility will work in unison with the existing Linac Coherent Light Source, which uses the legacy copper cavities in the last third of the linac to deliver electrons between 2 and 17 GeV to an undulator line. The upgrade plan inc...

  18. A review of wireless-photonic systems: Design methodologies and topologies, constraints, challenges, and innovations in electronics and photonics

    Science.gov (United States)

    Farsaei, Ahmadreza; Wang, Yun; Molavi, Reza; Jayatilleka, Hasitha; Caverley, Michael; Beikahmadi, Mohammad; Masnadi Shirazi, Amir Hossein; Jaeger, Nicolas; Chrostowski, Lukas; Mirabbasi, Shahriar

    2016-08-01

    Photonic networks form the backbone for data communications. In particular, in current and future wireless communication systems, photonic networks are becoming increasingly popular for data distribution between the central office and the remote antenna units at base stations. As wireless-photonic systems become in increasing demand, low-cost implementation of such systems will be desirable. This paper describes how integrated photonics and electronics, on silicon, can be used to design such systems. Various building blocks of such silicon-photonics systems are reviewed. The emphasis is on a 60 GHz wireless system which could be suitable for the emerging 5th-generation (5G) cellular networks. The implementation discussed here uses digital baseband optical transmission as opposed to the radio-over-fibre approach.

  19. Statistics of the variations of the high-energy electron population between 7 and 28 Jovian radii as measured by the Galileo spacecraft

    CERN Document Server

    Insoo, Jun; Swimm, R; Evans, R W; Clough, G

    2005-01-01

    Recent measurements of the high-energy, omni-directional electron environment by the Galileo spacecraft Energetic Particle Detector (EPD) have been analyzed in the range from 7 to 28 Jupiter radii. 10- min averages of these data between Jupiter orbit insertion in 1995 to the end of the mission have been analyzed to provide estimates of the electron differential fluxes at 1.5, 2, and 11 MeV in the Jovian equatorial plane as a function of radial distance. These data provide a long term picture of the variations in the high-energy electron environment over the ~8 years of the Galileo mission. This paper reviews those measurements and the statistics associated with them for the 8 year period. In general, the data variations are well behaved with variations being within a factor of ~2 of a median value at a given distance from Jupiter. These results are analyzed in detail and the orbit variations discussed in the context of the overall data set. The results of this analysis of the long-term statistical variations ...

  20. A battery-operated, stabilized, high-energy pulsed electron gun for the production of rare gas excimers.

    Science.gov (United States)

    Barcellan, L; Berto, E; Carugno, G; Galet, G; Galeazzi, G; Borghesani, A F

    2011-09-01

    We report on the design of a new type of hot-filament electron gun delivering fairly high current (a few hundreds of μ A) at high voltage (up to 100 kV) in continuous or pulsed mode. Its novel features are that the filament is heated by means of a pack of rechargeable batteries floated atop the high-voltage power supply in order to get rid of bulky isolation transformers, and that the filament current and, hence, the electron gun current, is controlled by a feedback circuit including a superluminescent diode decoupled from the high voltage by means of an optical fiber. This electron gun is intended for general purposes, although we have especially developed it to meet the needs of our experiment on the infrared emission spectroscopy of rare gas excimers. Our experiment requires that the charge injection into the sample is pulsed and constant and stable in time. The new electron gun can deliver several tens of nC per pulse of electrons of energy up to 100 keV into the sample cell. The new design also eliminates ripples in the emission current and ensures up to 12 h of stable performance. © 2011 American Institute of Physics

  1. PREFACE: XXVIth International Conference on Photonic, Electronic and Atomic Collisions

    Science.gov (United States)

    Orel, Ann; Starace, Anthony F.; Nikolić, Dragan; Berrah, Nora; Gorczyca, Thomas W.; Kamber, Emanuel Y.; Tanis, John A.

    2009-12-01

    The XXVIth International Conference on Photonic, Electronic and Atomic Collisions was held on the campus of Western Michigan University (WMU) in Kalamazoo during 22-28 July 2009. Kalamazoo, the home of a major state university amid pleasant surroundings, was a delightful place for the conference. The 473 scientific participants, 111 of whom were students, had many fruitful discussions and exchanges that contributed to the success of the conference. Participants from 43 countries made the conference truly international in scope. The 590 abstracts that were presented on the first four days formed the heart of the conference and provided ample opportunity for discussion. This change, allowing the conference to end with invited talks, was a departure from the format used at previous ICPEAC gatherings in which the conferences ended with a poster session. The abstracts were split almost equally between the three main conference areas, i.e., photonic, electronic, and atomic collisions, and the posters were distributed across the days of the conference so that approximately equal numbers of abstracts in the different areas were scheduled for each day. Of the total number of presented abstracts, 517 of these are included in this proceedings volume, the first time that abstracts have been published by ICPEAC. There were 5 plenary lectures covering the different areas of the conference: Paul Corkum (University of Ottawa) talked on attosecond physics with atoms and molecules, Serge Haroche (Collège de France) on non-destructive photon counting, Toshiyuki Azuma (Tokyo Metropolitan University) on resonant coherent excitation of highly-charged ions in crystals, Eva Lindroth (Stockholm University) on atomic structure effects, and Alfred Müller (Justus Liebig University) on resonance phenomena in electron- and photon-ion collisions. Two speakers gave very illuminating public lectures that drew many people from the local area, as well as conference participants: Patricia Dehmer

  2. Monitoring the transformation of aliphatic and fullerene molecules by high-energy electrons using surface-enhanced Raman spectroscopy

    Science.gov (United States)

    Mojarad, Nassir; Tisserant, Jean-Nicolas; Beyer, Hannes; Dong, Hao; Reissner, Patrick A.; Fedoryshyn, Yuriy; Stemmer, Andreas

    2017-04-01

    We report on using 100 keV electrons to obtain amorphous carbon from aliphatic and fullerene molecules, and study this process by monitoring their Raman signal. In this regard, we use self-assembled monolayers of gold nanoparticles to provide high electromagnetic field enhancement, which allows the detection of the Raman signal from even nanometer-thick layers of analyte. Our results show different dynamics in the amorphization process of the two molecules, although both show suppression of their original vibrational resonances even at low exposure doses. We have also used atomic-force microscopy to evaluate the sensitivity of the C60 molecules to electron beams in forming networks of amorphized molecules that are less soluble in the development process. This method allows precise patterning possibilities as well as in situ functionalization of carbonaceous thin films in the perspective of using in electronic device applications.

  3. A bifunctional ion-electron conducting interlayer for high energy density all-solid-state lithium-sulfur battery

    Science.gov (United States)

    Zhu, Yuewu; Li, Jie; Liu, Jin

    2017-05-01

    A bifunctional ion-electron conducting layer is designed for all-solid-state lithium-sulfur battery. This layer consists of electronic conductor and solid polymer electrolyte that is intercalated between the cathode and electrolyte. By forming a gradient of electrons and lithium ions, the electrochemical performance and interfacial compatibility of the battery are obviously enhanced. When a pure sulfur powder is directly used as an active material of the cathode, the battery with the interlayer delivers the initial discharge capacity of 1457 mAh g-1 and the discharge capacity of 792.8 mAh g-1 after 50 cycles at 0.5 C and 80 °C, while the battery with the same cathode and without the interlayer only has the discharge capacity of 291.9 mAh g-1 after the same number of cycles.

  4. Electron scattering by Ne, Ar and Kr at intermediate and high energies, 0.5-10 keV

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, G.; Roteta, M.; Manero, F. [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Departamento de Fusion y Particulas Elementales, Madrid (Spain); Blanco, F. [Universidad Complutense de Madrid, Facultad de Fisica, Departamento de Fisica Atomica Molecular y Nuclear, Madrid (Spain); Williart, A. [Universidad Nacional de Educacion a Distancia, Facultad de Ciencias, Departamento de Fisica de los Materiales, Madrid (Spain)

    1999-04-28

    Semi-empirical total cross sections for electron scattering of noble gases (Ne, Ar and Kr) in the energy range 0.5-10 keV have been obtained by combining transmission-beam measurements for impact energies up to 6 keV with an asymptotic behaviour at higher energies according to the Born-Bethe approximation. The influence of the forward electron scattering on the experimental system has been evaluated by means of a Monte Carlo electron transport simulation. Theoretical values have also been obtained by applying the Born approximation in the case of inelastic processes and by means of an atomic scattering potential for the elastic part. The results of these calculations show an excellent agreement with the semi-empirical values in the above-mentioned energy range. (author)

  5. Coherent manipulation of thermal transport by tunable electron-photon and electron-phonon interaction

    Science.gov (United States)

    Paolucci, Federico; Timossi, Giuliano; Solinas, Paolo; Giazotto, Francesco

    2017-06-01

    We propose a system where coherent thermal transport between two reservoirs in non-galvanic contact is modulated by independently tuning the electron-photon and the electron-phonon coupling. The scheme is based on two gate-controlled electrodes capacitively coupled through a dc-SQUID (superconducting quantum interference device) as an intermediate phase-tunable resonator. Thereby the electron-photon interaction is modulated by controlling the flux threading the dc-SQUID (superconducting quantum interference device) and the impedance of the two reservoirs, while the electron-phonon coupling is tuned by controlling the charge carrier concentration in the electrodes. To quantitatively evaluate the behavior of the system, we propose to exploit the graphene reservoirs. In this case, the scheme can work at temperatures reaching 1 K, with unprecedented temperature modulations as large as 245 mK, transmittance up to 99%, and energy conversion efficiency up to 50%. Finally, the accuracy of heat transport control allows us to use this system as an experimental tool to determine the electron-phonon coupling in two-dimensional electronic systems.

  6. Shielding high energy accelerators

    CERN Document Server

    Stevenson, Graham Roger

    2001-01-01

    After introducing the subject of shielding high energy accelerators, point source, line-of-sight models, and in particular the Moyer model. are discussed. Their use in the shielding of proton and electron accelerators is demonstrated and their limitations noted. especially in relation to shielding in the forward direction provided by large, flat walls. The limitations of reducing problems to those using it cylindrical geometry description are stressed. Finally the use of different estimators for predicting dose is discussed. It is suggested that dose calculated from track-length estimators will generally give the most satisfactory estimate. (9 refs).

  7. Computer simulations analysis for determining the polarity of charge generated by high energy electron irradiation of a thin film

    DEFF Research Database (Denmark)

    Malac, Marek; Hettler, Simon; Hayashida, Misa

    2017-01-01

    Detailed simulations are necessary to correctly interpret the charge polarity of electron beam irradiated thin film patch. Relying on systematic simulations we provide guidelines and movies to interpret experimentally the polarity of the charged area, to be understood as the sign of the electrost...

  8. Search for Higgs boson production via weak boson fusion and decaying to bb¯in association with a high-energy photon using the ATLAS detector

    CERN Document Server

    Liang, Zhijun; The ATLAS collaboration

    2017-01-01

    A search for the bb¯ decay of the Standard Model Higgs boson produced through vector boson fusion in association with a high transverse energy (ET) photon has been conducted with the ATLAS detector. The high-ET photon provides a distinct signature for both triggering and reducing the large QCD jet background present in the inclusive bb¯jj signature. The talk will focus on new trigger strategy implemented in 2016 data taking to target the specific final state as well as the implementation of the multivariate strategy for the signal extraction. This analysis has been combined with a complementary analysis in the more inclusive bb¯jj final state, which results in a significant improvement in the sensitivity. Results with pp collision data collected in 2015 and 2016 at a centre-of-mass energy of 13 TeV are presented.

  9. Review of two-photon exchange in electron scattering

    Energy Technology Data Exchange (ETDEWEB)

    J. Arrington, P. G. Blunden, W. Melnitchouk

    2011-10-01

    We review the role of two-photon exchange (TPE) in electron-hadron scattering, focusing in particular on hadronic frameworks suitable for describing the low and moderate Q^2 region relevant to most experimental studies. We discuss the effects of TPE on the extraction of nucleon form factors and their role in the resolution of the proton electric to magnetic form factor ratio puzzle. The implications of TPE on various other observables, including neutron form factors, electroproduction of resonances and pions, and nuclear form factors, are summarized. Measurements seeking to directly identify TPE effects, such as through the angular dependence of polarization measurements, nonlinear epsilon contributions to the cross sections, and via e+p to e-p cross section ratios, are also outlined. In the weak sector, we describe the role of TPE and gamma-Z interference in parity-violating electron scattering, and assess their impact on the extraction of the strange form factors of the nucleon and the weak charge of the proton.

  10. Effect of Grain Size on Void Formation during High-Energy Electron Irradiation of Austenitic Stainless Steel

    DEFF Research Database (Denmark)

    Singh, Bachu Narain

    1974-01-01

    ’ model based on the property of grain boundaries as neutral and unsaturable sinks for vacancies and self-interstitials. It is suggested that even in the presence of sufficiently large amount of impurity gas atoms, a critical level of vacancy supersaturation is necessary to produce critically sized......Thin foils of an ‘ experimental ’ austenitic stainless steel, with and without dispersions of aluminium oxide particles, are irradiated with 1 MeV electrons in a High Voltage Electron Microscope at 600°C. Evidence of grain size dependent void nucleation, void concentration, and void volume swelling...... are presented for grains in the size range 0°45 to 50 μ. In both undoped and helium-doped samples the void nucleation is delayed, void concentration is lowered, and void volume swelling is reduced by decreasing the size of the grain under irradiation. The results are discussed in terms of a ‘ defect depletion...

  11. Effects of High Energy Electron Irradiation on a Yttrium Barium(2) Copper(3) Oxygen(7-delta) High Temperature Superconductor

    Science.gov (United States)

    1991-09-01

    expulsion of magnetic fields from the interior of a superconductor such that B = 0 and is the phenome- non that explains magnetic levitation . From Ohm’s Law...2Cu 30 7 - HIGH TEMPERATURE SUPERCONDUCTOR by Sean Mark Connors September 1991 Thesis Advisor: X. K. Maruyama Approved for public release...if necessary and identify by btock numbe,) FiE GP<P ,€ 5 pCOO HIGH TEMPERATURE SUPERCONDUCTORS , IRRADIATION EFFECTS, ELECTRON IRRADIATION

  12. Comparison of Exact Results for the Virtual Corrections to Bremsstrahlung in Electron-Positron Annihilation at High Energies

    CERN Document Server

    Yost, S.A.; Jadach, S.; Ward, B.F.L.

    2004-01-01

    We have compared the virtual corrections to electron-positron annihilation to fermion pairs with single hard bremsstrahlung as calculated by S. Jadach, M. Melles, B.F.L. Ward and S.A. Yost to several other expressions. The most recent of these comparisons is to the leptonic tensor calculated by J.H. Kuhn and G. Rodrigo for radiative return. Agreement is found to within $10^{-5}$ or better, as a fraction of the Born cross section.

  13. Measurements of Coulomb Cross Section for Production of Direct Electron-pairs by High Energy Ions at the CERN SPS

    CERN Multimedia

    2002-01-01

    QED predicts copious direct electron pair production by ultrarelativistic heavy nuclei in a high Z medium such as nuclear emulsion. First order QED calculations (combined screening and non-screening) for this process show that 1000@+32 electron pairs above 100~keV energy) should be emitted for a total |1|6O track length of 10.9~m in nuclear emulsion at 200~GeV/AMU. Emulsion exposures with oxygen (and other nuclei if available) at 60 and 200~GeV/AMU will be used to calibrate the energy dependent cross section @s~@j~(1n~E)|2|-|3, whose exponent depends on atomic screening. The oxygen tracks in the developed emulsions will be scanned with a microscope, and the number of direct electron pairs will be counted for individual tracks. The exposed stacks will contain sufficient emulsion (and CR39 plastic to check for possible interactions) that adequate path length will be available for exposures to @$>$~10|4~ions at each energy and ion species. \\\\ \\\\ If the absolute value of this cross section is confirmed as large a...

  14. SU-E-T-126: Non-Reference Condition Correction Factor KNR of Typical Radiation Detectors for the Dosimetry of High-Energy Photons.

    Science.gov (United States)

    Chofor, N; Poppe, B; Harder, D

    2012-06-01

    To correct for the deviations of the detector response when typical radiation detectors are used under non-reference conditions, factor kNR was calculated from the known energy dependence of the detector response at photon energies from 10 keV upwards and from clinical photon spectra within a large water phantom beneath a Siemens Primus 6/15 MV linac. A Farmer type ion chamber (NE2571), two TLD detector types and two diodes were investigated. Factor kNR was obtained as the ratio of the weighted responses Yt of a given detector t under reference conditions xref (axial distance r = 0 cm, depth d = 10 cm, field size 10 × 10 cm2 and SSD = 100 cm) and that under non-reference conditions × (off-axis points and depths for various field sizes); kNR = Yt(xref)/Yt(x). For small field (SF) dosimetry, we evaluated correction factor kNRSF, which refers to small field reference conditions (4 × 4 cm2 field). For all detectors investigated, the deviations of kNR from unity were highest outside the field, due to prevailing low-energy scatter contributions. For the Farmer chamber and EDP-10 diode, the kNR deviations did not exceed 2%, but were up to 60% for the EDD-5 diode, while kNR values for LiF:Mg,Cu,P and LiF:Mg,Ti deviated at most 15% and 5% respectively. kNR values appear as unique functions of the mean photon energy at the point of interest. Air-filled ion chambers show only small kNR variations, while for non-water equivalent detectors, kNR variations depend on the detector response at low photon energy. kNR can be presented as a unique function of the mean photon energy at the point of interest. A 4 × 4 cm2 reference field is recommended for small fields, with correction factor kNRSF varying almost negligibly from kNR except for unshielded Si diodes. © 2012 American Association of Physicists in Medicine.

  15. Characteristics of photodiodes with «intrinsic oxide — InSe» structure, irradiated with high-energy electrons

    Directory of Open Access Journals (Sweden)

    Sydor O. N.

    2012-12-01

    Full Text Available The article describes the research of the influence of electrons with an effective energy of 12 MeV in the 0,33—33 Mrad dose range on the electrical and photovoltaic properties of photodiodes with «intrinsic oxide — p-InSe» structure. It has been found that the minimum dose improves their basic parameters, while the maximum dose significantly reduces the short circuit current and devices photosensitivity. In this case, an increase in volt-watt sensitivity and a minimal increase in coupling coefficient of the I-V characteristic are observed.

  16. Aluminum, copper, tin and lead as shielding materials in the treatment of cancer with high-energy electrons

    Science.gov (United States)

    Prasad, S. Guru; Parthasaradhi, K.; Bloomer, W. D.; Al-Najjar, W. H.; McMahon, J.; Thomson, O.

    1998-10-01

    During irradiation of lesions in cancer treatment with electrons, irregular field sizes are shaped by blocking off the areas to be protected usually with lead or Lepowitz metal of adequate thickness. Sometimes these blocks are placed directly on the skin. In such cases, the block should not only be of minimum weight (thickness), but also the residual dose received by the protected organs should be as small as possible. However, due to the production of bremsstrahlung, it is difficult to achieve a higher degree of attenuation unless a sufficient thickness of shielding material is used. Hence, a minimum or optimum thickness is needed to be measured. Transmission measurements are performed to determine suitable minimum thicknesses and to measure the transmission at this minimum thickness, for aluminum, copper, tin and lead for electron broad-beam field sizes 6×6, 10×10 and 20×20 cm 2 of energies 6, 12 and 20 MeV produced by a medical linear accelerator. The ratio of the measured ionization with and without the shielding material in percent is expressed as a measure of transmission. The minimum thickness is `knee' position of the transmission curves, where the dose received by the organs (residual dose) is mostly dominated by the bremsstrahlung component and any addition of shielding material is not of much advantage in achieving further appreciable shielding effect. It is noticed that at this minimum thickness the percentage dose received by the vital organs behind the shield varies from 1 to 14% of the original unshielded dose as the atomic number of the shielding material increases from 13 (aluminum) to 82 (lead) and as the electron energy of the beam increases from 6 to 20 MeV. In other words, the effectiveness of shielding decreases from 99 to 86% as the atomic number increases from 13 to 82. Depending on the treatment volume, its position and the clearance between the electron cone and the skin, the dose received by the vital organs surrounding the tumor can

  17. On Possible Interpretations of the High Energy Electron-Positron Spectrum Measured by the Fermi Large Area Telescope

    Energy Technology Data Exchange (ETDEWEB)

    Grasso, D.; Profumo, S.; Strong, A.W.; Baldini, L.; Bellazzini, R.; Bloom, E.D.; Bregeon, J.; Di Bernardo, G.; Gaggero, D.; Giglietto, N.; Kamae, T.; Latronico, L.; Longo, F.; Mazziotta, M.N.; Moiseev, A.A.; Morselli, A.; Ormes, J.F.; Pesce-Rollins, M.; Pohl, M.; Razzano, M.; Sgro, C.

    2009-05-15

    The Fermi-LAT experiment recently reported high precision measurements of the spectrum of cosmic-ray electrons-plus-positrons (CRE) between 20 GeV and 1 TeV. The spectrum shows no prominent spectral features, and is significantly harder than that inferred from several previous experiments. Here we discuss several interpretations of the Fermi results based either on a single large scale Galactic CRE component or by invoking additional electron-positron primary sources, e.g. nearby pulsars or particle Dark Matter annihilation. We show that while the reported Fermi-LAT data alone can be interpreted in terms of a single component scenario, when combined with other complementary experimental results, specifically the CRE spectrum measured by H.E.S.S. and especially the positron fraction reported by PAMELA between 1 and 100 GeV, that class of models fails to provide a consistent interpretation. Rather, we find that several combinations of parameters, involving both the pulsar and dark matter scenarios, allow a consistent description of those results. We also briefly discuss the possibility of discriminating between the pulsar and dark matter interpretations by looking for a possible anisotropy in the CRE flux.

  18. CALET: High energy cosmic ray observatory on International Space Station

    Science.gov (United States)

    Mori, Masaki; CALET Collaboration

    2012-12-01

    The CALorimeteric Electron Telescope (CALET) is a Japanese-led international mission being developed as part of the utilization plan for the International Space Station (ISS). CALET will be launched by an H-II B rocket utilizing the Japanese developed HTV (H-II Transfer Vehicle) in 2014. The instrument will be robotically emplaced upon the Exposed Facility attached to the Japanese Experiment Module (JEM-EF). CALET is a calorimeter based instrument which will have superior energy resolution and excellent separation between hadrons and electrons and between charged particles and gamma rays in the GeV to trans-TeV energy range. CALET will address many questions in high energy astrophysics, including (1) the nature of the sources of high energy particles and photons, through the high energy electron spectrum, (2) signatures of dark matter, in either the high energy electron or gamma ray spectrum, (3) the details of particle propagation in the Galaxy, by a combination of energy spectrum measurements of electrons, protons and highercharged nuclei. In this paper the outline and current status of CALET are summarized.

  19. Computer simulations analysis for determining the polarity of charge generated by high energy electron irradiation of a thin film.

    Science.gov (United States)

    Malac, Marek; Hettler, Simon; Hayashida, Misa; Kawasaki, Masahiro; Konyuba, Yuji; Okura, Yoshi; Iijima, Hirofumi; Ishikawa, Isamu; Beleggia, Marco

    2017-09-01

    Detailed simulations are necessary to correctly interpret the charge polarity of electron beam irradiated thin film patch. Relying on systematic simulations we provide guidelines and movies to interpret experimentally the polarity of the charged area, to be understood as the sign of the electrostatic potential developed under the beam with reference to a ground electrode. We discuss the two methods most frequently used to assess charge polarity: Fresnel imaging of the irradiated area and Thon rings analysis. We also briefly discuss parameter optimization for hole free phase plate (HFPP) imaging. Our results are particularly relevant to understanding contrast of hole-free phase plate imaging and Berriman effect. Copyright © 2017. Published by Elsevier Ltd.

  20. Search for Higgs boson production via weak boson fusion and decaying to $b \\bar b$ in association with a high-energy photon in the ATLAS detector

    CERN Document Server

    The ATLAS collaboration

    2016-01-01

    A search has been conducted for the $b\\bar b$ decay of the Standard Model Higgs boson produced through vector boson fusion in association with a photon and two jets. The search in this $b\\bar b \\gamma jj$ signature benefits from a large reduction of QCD jet background relative to the inclusive $b\\bar b j j$ signature and from the presence of a high-tranverse-momentum photon for triggering. Results are reported from the analysis of 12.6 fb$^{-1}$ of LHC proton-proton collision data at $\\sqrt{s} = 13$ TeV collected with the ATLAS detector. The observed 95\\% confidence level upper limit on the production cross section times branching ratio for a Higgs mass of 125 GeV is $4.0$ times the Standard Model expectation, and the expected upper limit is $6.0^{+2.3}_{-1.7}$. The measured signal strength is $\\mu=-3.9^{+2.8}_{-2.7}$ times the Standard Model value. The analysis methods are also used to search for $Z+\\gamma$ vector boson fusion production in the same $b\\bar b \\gamma j j$ signature. The observed upper limit on...

  1. Study of photon emission by electron capture during solar nuclei acceleration. 3: Photon production evaluations

    Science.gov (United States)

    Perez-Peraza, J.; Alvarez, M.; Gallegos, A.

    1985-01-01

    Lower limits of photon fluxes were evaluated from electron capture during acceleration in solar flares, because the arbitrary q sub c asterisk assumed in this work evolves very slow with velocity, probably much more slowly than the physical actual situation: in fact, more emission is expected toward the IR region. Nevertheless the authors claim to show that the factibility of sounding acceleration processes, charge evolution processes and physical parameters of the source itself, by the observational analysis of this kind of emissions. For instance, it would be interesting to search observationally, for the predicted flux and energy drift of F sub e ions interacting with the atomic 0 and F sub e of the source matter, or, even more feasible for the X-ray lines at 4.2 keV and 2.624 + 0.003 KeV from Fe and S ions in ionized Fe at T = 10 to the 7th power K respectively, the 418 + or - 2 eV and 20 + or - 4 eV lines of Fe and S in ionized Fe at 5 x 10 to the 6th power K, which are predicted from Fermi acceleration.

  2. Photon counting imaging and centroiding with an electron-bombarded CCD using single molecule localisation software

    Energy Technology Data Exchange (ETDEWEB)

    Hirvonen, Liisa M.; Barber, Matthew J.; Suhling, Klaus, E-mail: klaus.suhling@kcl.ac.uk

    2016-06-01

    Photon event centroiding in photon counting imaging and single-molecule localisation in super-resolution fluorescence microscopy share many traits. Although photon event centroiding has traditionally been performed with simple single-iteration algorithms, we recently reported that iterative fitting algorithms originally developed for single-molecule localisation fluorescence microscopy work very well when applied to centroiding photon events imaged with an MCP-intensified CMOS camera. Here, we have applied these algorithms for centroiding of photon events from an electron-bombarded CCD (EBCCD). We find that centroiding algorithms based on iterative fitting of the photon events yield excellent results and allow fitting of overlapping photon events, a feature not reported before and an important aspect to facilitate an increased count rate and shorter acquisition times.

  3. A mirrorless photonic free-electron laser oscillator

    NARCIS (Netherlands)

    van der Slot, P.J.M.; Strooisma, A.; Denis, T.; Boller, Klaus J.

    2017-01-01

    Photonic crystals have been used to provide fundamental control over the interaction between light and matter, including stimulated emission. For example, in Bloch-mode lasers, the photonic crystal provides field enhancement through reduced group velocity and offers larger mode volumes through

  4. Photonics Applications and Web Engineering: WILGA 2017

    Science.gov (United States)

    Romaniuk, Ryszard S.

    2017-08-01

    XLth Wilga Summer 2017 Symposium on Photonics Applications and Web Engineering was held on 28 May-4 June 2017. The Symposium gathered over 350 participants, mainly young researchers active in optics, optoelectronics, photonics, modern optics, mechatronics, applied physics, electronics technologies and applications. There were presented around 300 oral and poster papers in a few main topical tracks, which are traditional for Wilga, including: bio-photonics, optical sensory networks, photonics-electronics-mechatronics co-design and integration, large functional system design and maintenance, Internet of Things, measurement systems for astronomy, high energy physics experiments, and other. The paper is a traditional introduction to the 2017 WILGA Summer Symposium Proceedings, and digests some of the Symposium chosen key presentations. This year Symposium was divided to the following topical sessions/conferences: Optics, Optoelectronics and Photonics, Computational and Artificial Intelligence, Biomedical Applications, Astronomical and High Energy Physics Experiments Applications, Material Research and Engineering, and Advanced Photonics and Electronics Applications in Research and Industry.

  5. Evaluation of Monte Carlo tools for high energy atmospheric physics

    Science.gov (United States)

    Rutjes, Casper; Sarria, David; Broberg Skeltved, Alexander; Luque, Alejandro; Diniz, Gabriel; Østgaard, Nikolai; Ebert, Ute

    2016-11-01

    The emerging field of high energy atmospheric physics (HEAP) includes terrestrial gamma-ray flashes, electron-positron beams and gamma-ray glows from thunderstorms. Similar emissions of high energy particles occur in pulsed high voltage discharges. Understanding these phenomena requires appropriate models for the interaction of electrons, positrons and photons of up to 40 MeV energy with atmospheric air. In this paper, we benchmark the performance of the Monte Carlo codes Geant4, EGS5 and FLUKA developed in other fields of physics and of the custom-made codes GRRR and MC-PEPTITA against each other within the parameter regime relevant for high energy atmospheric physics. We focus on basic tests, namely on the evolution of monoenergetic and directed beams of electrons, positrons and photons with kinetic energies between 100 keV and 40 MeV through homogeneous air in the absence of electric and magnetic fields, using a low energy cutoff of 50 keV. We discuss important differences between the results of the different codes and provide plausible explanations. We also test the computational performance of the codes. The Supplement contains all results, providing a first benchmark for present and future custom-made codes that are more flexible in including electrodynamic interactions.

  6. Probing Electron-Phonon Interaction through Two-Photon Interference in Resonantly Driven Semiconductor Quantum Dots

    DEFF Research Database (Denmark)

    Reigue, Antoine; Iles-Smith, Jake; Lux, Fabian

    2017-01-01

    We investigate the temperature dependence of photon coherence properties through two-photon interference (TPI) measurements from a single quantum dot (QD) under resonant excitation. We show that the loss of indistinguishability is related only to the electron-phonon coupling and is not affected...

  7. Hardness and wear resistance of steel-based surface composites fabricated with Fe-based metamorphic alloy powders by high-energy electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyuhong [Center for Advanced Aerospace Materials, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Nam, Duk-Hyun [Center for Advanced Aerospace Materials, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Lee, Sunghak [Center for Advanced Aerospace Materials, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of)]. E-mail: shlee@postech.ac.kr; Kim, Choongnyun Paul [Center for Advanced Aerospace Materials, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of)

    2006-07-25

    In this study, steel-based surface composites were fabricated with Fe-based metamorphic alloy powders by high-energy electron beam irradiation, and their microstructure, hardness, and wear resistance were investigated. Two kinds of Fe-based metamorphic powders were deposited on a plain carbon steel substrate, and then electron beam was irradiated on these powders to fabricate one-layered surface composites. Two-layered surface composites were also fabricated by irradiating electron beam again onto the powders deposited on the one-layered surface composites. The composite layers of 2.6-3.1 mm in thickness were homogeneously formed without defects, and contained a large amount (up to 64 vol.%) of Cr{sub 2}B or Cr{sub 1.65}Fe{sub 0.35}B{sub 0.96} borides in the Cr{sub 0.19}Fe{sub 0.7}Ni{sub 0.11} or martensite matrix. Since the hardness and wear resistance of the surface composite layers were directly influenced by hard borides, they were two to four times greater than those of the steel substrate. These borides also played a role in improving the high-temperature hardness because they are insoluble and thermally stable even at high temperatures. These findings suggested that various applications of the fabricated surface composites to materials requiring high resistance to heat and abrasion were expected.

  8. Upward high-energy field-aligned electron beams above the polar edge of auroral oval: observations from the SKA-3 instruments onboard the Auroral Probe (Interball-2

    Directory of Open Access Journals (Sweden)

    V. A. Stepanov

    1998-09-01

    Full Text Available A new phenomenon was found at the polar edge of the auroral oval in the postmidnight-morning sectors: field-aligned (FA high-energy upward electron beams in the energy range 20–40 keV at altitudes about 3RE, accompanied by bidirectional electron FA beams of keV energy. The beam intensity often reaches more than 0.5·103 electrons/s·sr·keV·cm2, and the beams are observed for a relatively long time (~3·102–103s, when the satellite at the apogee moves slowly in the ILAT-MLT frame. A qualitative scenario of the acceleration mechanism is proposed, according to which the satellite is within a region of bidirectional acceleration where a stochastic FA acceleration is accomplished by waves with fluctuating FA electric field components in both directions.Key words. Ionosphere (particle acceleration; wave-particle interactions · Magnetospheric physics (magnetosphere-ionosphere interactions

  9. Photonics

    CERN Document Server

    Andrews, David L

    2015-01-01

    Discusses the basic physical principles underlying Biomedical Photonics, spectroscopy and microscopy This volume discusses biomedical photonics, spectroscopy and microscopy, the basic physical principles underlying the technology and its applications. The topics discussed in this volume are: Biophotonics; Fluorescence and Phosphorescence; Medical Photonics; Microscopy; Nonlinear Optics; Ophthalmic Technology; Optical Tomography; Optofluidics; Photodynamic Therapy; Image Processing; Imaging Systems; Sensors; Single Molecule Detection; Futurology in Photonics. Comprehensive and accessible cov

  10. Photonics

    CERN Document Server

    Andrews, David L

    2015-01-01

    Discusses the basic physical principles underlying thescience and technology of nanophotonics, its materials andstructures This volume presents nanophotonic structures and Materials.Nanophotonics is photonic science and technology that utilizeslight/matter interactions on the nanoscale where researchers arediscovering new phenomena and developing techniques that go wellbeyond what is possible with conventional photonics andelectronics.The topics discussed in this volume are: CavityPhotonics; Cold Atoms and Bose-Einstein Condensates; Displays;E-paper; Graphene; Integrated Photonics; Liquid Cry

  11. Photonics

    CERN Document Server

    Andrews, David L

    2015-01-01

    Discusses the basic physical principles underlying the technology instrumentation of photonics This volume discusses photonics technology and instrumentation. The topics discussed in this volume are: Communication Networks; Data Buffers; Defense and Security Applications; Detectors; Fiber Optics and Amplifiers; Green Photonics; Instrumentation and Metrology; Interferometers; Light-Harvesting Materials; Logic Devices; Optical Communications; Remote Sensing; Solar Energy; Solid-State Lighting; Wavelength Conversion Comprehensive and accessible coverage of the whole of modern photonics Emphas

  12. Photonics

    CERN Document Server

    Andrews, David L

    2015-01-01

    This book covers modern photonics accessibly and discusses the basic physical principles underlying all the applications and technology of photonicsThis volume covers the basic physical principles underlying the technology and all applications of photonics from statistical optics to quantum optics. The topics discussed in this volume are: Photons in perspective; Coherence and Statistical Optics; Complex Light and Singular Optics; Electrodynamics of Dielectric Media; Fast and slow Light; Holography; Multiphoton Processes; Optical Angular Momentum; Optical Forces, Trapping and Manipulation; Pol

  13. Photon and primary electron arithmetics in photoconductors for digital mammography: Monte Carlo simulation studies

    Energy Technology Data Exchange (ETDEWEB)

    Sakellaris, T; Spyrou, G; Panayiotakis, G [University of Patras, School of Medicine, Department of Medical Physics, Patras, 26500 (Greece); Tzanakos, G [University of Athens, Department of Physics, Div. Nucl. and Particle Physics, Athens, 15771 (Greece)], E-mail: panayiot@upatras.gr

    2009-06-15

    Materials like CdTe, CdZnTe, Cd{sub 0.8}Zn{sub 0.2}Te and ZnTe are suitable photoconductors for direct conversion digital flat panel x-ray image detectors. The x-ray induced primary electrons inside photoconductor's bulk comprise the initial signal that propagates and forms the final signal (image) on detector's electrodes. An already developed Monte Carlo model that simulates the primary electron generation in photoconducting materials, such as those mentioned above, has been used to study the arithmetics of fluorescent photons, escaping photons and primary electrons in these materials in the mammographic energy range. In this way insights are gained concerning the primitive stage of signal formation that lead to the investigation of the factors that affect the primary electron generation. It was found that for the typical photoconductor thicknesses (300-1000 {mu}m): (i) in all materials and incident energies the escaping of primary photons is negligible and does not influence the number of primary electrons, (ii) the overwhelming majority of escaping photons is backwards escaping fluorescent photons, (iii) the number of primary electrons increases at energies higher than Cd and Te K-edges where the fluorescent photon escaping decreases and their absorption is followed by long atomic deexcitation cascades and (iv) ZnTe has the maximum number of primary electrons produced for energies between 16 and 26 keV while CdTe for higher energies.

  14. Percentage depth dose calculation accuracy of model based algorithms in high energy photon small fields through heterogeneous media and comparison with plastic scintillator dosimetry.

    Science.gov (United States)

    Alagar, Ananda Giri Babu; Mani, Ganesh Kadirampatti; Karunakaran, Kaviarasu

    2016-01-08

    Small fields smaller than 4 × 4 cm2 are used in stereotactic and conformal treatments where heterogeneity is normally present. Since dose calculation accuracy in both small fields and heterogeneity often involves more discrepancy, algorithms used by treatment planning systems (TPS) should be evaluated for achieving better treatment results. This report aims at evaluating accuracy of four model-based algorithms, X-ray Voxel Monte Carlo (XVMC) from Monaco, Superposition (SP) from CMS-Xio, AcurosXB (AXB) and analytical anisotropic algorithm (AAA) from Eclipse are tested against the measurement. Measurements are done using Exradin W1 plastic scintillator in Solid Water phantom with heterogeneities like air, lung, bone, and aluminum, irradiated with 6 and 15 MV photons of square field size ranging from 1 to 4 cm2. Each heterogeneity is introduced individually at two different depths from depth-of-dose maximum (Dmax), one setup being nearer and another farther from the Dmax. The central axis percentage depth-dose (CADD) curve for each setup is measured separately and compared with the TPS algorithm calculated for the same setup. The percentage normalized root mean squared deviation (%NRMSD) is calculated, which represents the whole CADD curve's deviation against the measured. It is found that for air and lung heterogeneity, for both 6 and 15 MV, all algorithms show maximum deviation for field size 1 × 1 cm2 and gradually reduce when field size increases, except for AAA. For aluminum and bone, all algorithms' deviations are less for 15 MV irrespective of setup. In all heterogeneity setups, 1 × 1 cm2 field showed maximum deviation, except in 6MV bone setup. All algorithms in the study, irrespective of energy and field size, when any heterogeneity is nearer to Dmax, the dose deviation is higher compared to the same heterogeneity far from the Dmax. Also, all algorithms show maximum deviation in lower-density materials compared to high-density materials.

  15. FSU High Energy Physics

    Energy Technology Data Exchange (ETDEWEB)

    Prosper, Harrison B. [Florida State Univ., Tallahassee, FL (United States); Adams, Todd [Florida State Univ., Tallahassee, FL (United States); Askew, Andrew [Florida State Univ., Tallahassee, FL (United States); Berg, Bernd [Florida State Univ., Tallahassee, FL (United States); Blessing, Susan K. [Florida State Univ., Tallahassee, FL (United States); Okui, Takemichi [Florida State Univ., Tallahassee, FL (United States); Owens, Joseph F. [Florida State Univ., Tallahassee, FL (United States); Reina, Laura [Florida State Univ., Tallahassee, FL (United States); Wahl, Horst D. [Florida State Univ., Tallahassee, FL (United States)

    2014-12-01

    non-zero neutrino masses or the overwhelming astrophysical evidence for an invisible form of matter, called dark matter, that has had a marked effect on the evolution of structure in the universe. The report highlights the main, recent, experimental achievements of the experimental group, which include the investigation of properties of the W and Z bosons; the search for new heavy stable charged particles and the search for a proposed property of nature called supersymmetry in proton-proton collisions that yield high energy photons. In addition, we report a few results from a more general search for supersymmetry at the LHC, initiated by the group. The report also highlights the group's significant contributions, both theoretical and experimental, to the 2012 discovery of the Higgs boson and the measurement of its properties.

  16. Design of Pixellated CMOS Photon Detector for Secondary Electron Detection in the Scanning Electron Microscope

    Directory of Open Access Journals (Sweden)

    Joon Huang Chuah

    2011-01-01

    Full Text Available This paper presents a novel method of detecting secondary electrons generated in the scanning electron microscope (SEM. The method suggests that the photomultiplier tube (PMT, traditionally used in the Everhart-Thornley (ET detector, is to be replaced with a configurable multipixel solid-state photon detector offering the advantages of smaller dimension, lower supply voltage and power requirements, and potentially cheaper product cost. The design of the proposed detector has been implemented using a standard 0.35 μm CMOS technology with optical enhancement. This microchip comprises main circuit constituents of an array of photodiodes connecting to respective noise-optimised transimpedance amplifiers (TIAs, a selector-combiner (SC circuit, and a postamplifier (PA. The design possesses the capability of detecting photons with low input optical power in the range of 1 nW with 100 μm × 100 μm sized photodiodes and achieves a total amplification of 180 dBΩ at the output.

  17. Fabrication and characterisation of phantom material made of Tannin-added Rhizophora spp. particleboards for photon and electron beams

    Science.gov (United States)

    Yusof, M. F. Mohd; Hamid, P. N. K. Abd; Tajuddin, A. A.; Hashim, R.; Bauk, S.; Isa, N. Mohd; Isa, M. J. Md

    2017-05-01

    Particleboards made of Rhizophora spp. with addition of tannin adhesive were fabricated at target density of 1.0 g/cm3. The physical and mechanical properties of the particleboards including internal bond strength (IB) and modulus of rupture (MOR) were measured based on Japanese Industrial Standards (JIS A-5908). The characterisation of the particleboards including the effective atomic number, CT number and relative electron density were determined and compared to water. The mass attenuation coefficient of the particleboards were measured and compared to the calculated value of water using photon cross-section database (XCOM). The results showed that the physical and mechanical properties of the particleboards complied with Type 13 and 18 of JIS A-5908. The values of effective atomic number, CT number and relative electron density were also close to the value of water. The value of mass attenuation coefficients of the particleboards showed good agreement with water (XCOM) at low and high energy photon indicated by the χ2 values.

  18. Electron and photon reconstruction and performance in ATLAS using a dynamical, topological cell clustering-based approach

    CERN Document Server

    The ATLAS collaboration

    2017-01-01

    The electron and photon reconstruction in ATLAS has moved towards the use of a dynamical, topo- logical cell-based approach for cluster building, owing to advancements in the calibration procedure which allow for such a method to be applied. The move to this new technique allows for improved measurements of electron and photon energies, particularly in situations where an electron radiates a bremsstrahlung photon, or a photon converts to an electron-poistron pair. This note details the changes to the ATLAS electron and photon reconstruction software, and assesses its performance under current LHC luminosity conditions using simulated data. Changes to the converted photon reconstruction are also detailed, which improve the reconstruction efficiency of double-track converted photons, as well as reducing the reconstruction of spurious one-track converted photons. The performance of the new reconstruction algorithm is also presented in a number of important topologies relevant to precision Standard Model physics,...

  19. Cavity-photon contribution to the effective interaction of electrons in parallel quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, Vidar [Science Institute, University of Iceland, Reykjavik (Iceland); Sitek, Anna [Science Institute, University of Iceland, Reykjavik (Iceland); Department of Theoretical Physics, Faculty of Fundamental Problems of Technology, Wroclaw University of Technology (Poland); Abdullah, Nzar Rauf [Science Institute, University of Iceland, Reykjavik (Iceland); Physics Department, Faculty of Science and Science Education, School of Science, University of Sulaimani, Kurdistan Region (Iraq); Tang, Chi-Shung [Department of Mechanical Engineering, National United University, Miaoli (China); Manolescu, Andrei [School of Science and Engineering, Reykjavik University (Iceland)

    2016-05-15

    A single cavity photon mode is expected to modify the Coulomb interaction of an electron system in the cavity. Here we investigate this phenomena in a parallel double quantum dot system. We explore properties of the closed system and the system after it has been opened up for electron transport. We show how results for both cases support the idea that the effective electron-electron interaction becomes more repulsive in the presence of a cavity photon field. This can be understood in terms of the cavity photons dressing the polarization terms in the effective mutual electron interaction leading to nontrivial delocalization or polarization of the charge in the double parallel dot potential. In addition, we find that the effective repulsion of the electrons can be reduced by quadrupolar collective oscillations excited by an external classical dipole electric field. (copyright 2015 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  20. Measurement of the BESSY II electron beam energy by Compton-backscattering of laser photons

    CERN Document Server

    Klein, R; Thornagel, R; Brandt, G; Görgen, R; Ulm, G

    2002-01-01

    Accurate knowledge of all storage ring parameters is essential for the Physikalisch-Technische Bundesanstalt (PTB) to operate the electron storage ring BESSY II as a primary source standard. One parameter entering the Schwinger equation for the calculation of the spectral photon flux of bending magnet radiation is the electron beam energy. So at BESSY II the electron beam energy is measured by two independent techniques one of which is described in this paper: the photons from a CO sub 2 -laser are scattered in a head-on collision with the stored electrons. From the spectrum of the backscattered photons that are detected by an energy-calibrated HPGe detector the electron beam energy can be determined. The experimental set-up at the BESSY II electron storage ring as well as the current experimental status are described for operation of the storage ring at the energies of 900 and 1700 MeV.

  1. The role of symmetry in the theory of inelastic high-energy electron scattering and its application to atomic-resolution core-loss imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dwyer, C., E-mail: c.dwyer@fz-juelich.de [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, Jülich D-52425 (Germany); Peter Grünberg Institute, Forschungszentrum Jülich, Jülich D-52425 (Germany)

    2015-04-15

    The inelastic scattering of a high-energy electron in a solid constitutes a bipartite quantum system with an intrinsically large number of excitations, posing a considerable challenge for theorists. It is demonstrated how and why the utilization of symmetries, or approximate symmetries, can lead to significant improvements in both the description of the scattering physics and the efficiency of numerical computations. These ideas are explored thoroughly for the case of core-loss excitations, where it is shown that the coupled angular momentum basis leads to dramatic improvements over the bases employed in previous work. The resulting gains in efficiency are demonstrated explicitly for K-, L- and M-shell excitations, including such excitations in the context of atomic-resolution imaging in the scanning transmission electron microscope. The utilization of other symmetries is also discussed. - Highlights: • It is explained how and why symmetry improves the efficiency of inelastic scattering calculations in general. • This includes approximate symmetries, which are often easier to specify. • Specific examples are given for core-loss scattering in STEM. • The utilization of approximate symmetries associated with ELNES, the detector geometry, and the energy loss are also discussed.

  2. Artificial construction of the layered Ruddlesden-Popper manganite La2Sr2Mn3O10 by reflection high energy electron diffraction monitored pulsed laser deposition.

    Science.gov (United States)

    Palgrave, Robert G; Borisov, Pavel; Dyer, Matthew S; McMitchell, Sean R C; Darling, George R; Claridge, John B; Batuk, Maria; Tan, Haiyan; Tian, He; Verbeeck, Jo; Hadermann, Joke; Rosseinsky, Matthew J

    2012-05-09

    Pulsed laser deposition has been used to artificially construct the n = 3 Ruddlesden-Popper structure La(2)Sr(2)Mn(3)O(10) in epitaxial thin film form by sequentially layering La(1-x)Sr(x)MnO(3) and SrO unit cells aided by in situ reflection high energy electron diffraction monitoring. The interval deposition technique was used to promote two-dimensional SrO growth. X-ray diffraction and cross-sectional transmission electron microscopy indicated that the trilayer structure had been formed. A site ordering was found to differ from that expected thermodynamically, with the smaller Sr(2+) predominantly on the R site due to kinetic trapping of the deposited cation sequence. A dependence of the out-of-plane lattice parameter on growth pressure was interpreted as changing the oxygen content of the films. Magnetic and transport measurements on fully oxygenated films indicated a frustrated magnetic ground state characterized as a spin glass-like magnetic phase with the glass temperature T(g) ≈ 34 K. The magnetic frustration has a clear in-plane (ab) magnetic anisotropy, which is maintained up to temperatures of 150 K. Density functional theory calculations suggest competing antiferromagnetic and ferromagnetic long-range orders, which are proposed as the origin of the low-temperature glassy state.

  3. Measurement of radio wave reflection due to temperature rising from rock salt and ice irradiated by an electron beam for an ultra-high-energy neutrino detector

    Energy Technology Data Exchange (ETDEWEB)

    Tanikawa, Takahiro; Chiba, Masami; Kamijo, Toshio; Yabuki, Fumiaki; Yasuda, Osamu; Akiyama, Hidetoshi; Chikashige, Yuichi; Kon, Tadashi; Shimizu, Yutaka; Utsumi, Michiaki; Fujii, Masatoshi [Graduate School of Science and Engineering, Tokyo Metropolitan University, 1-1 Minami-Ohsawa, Hachioji-shi, Tokyo 192-0397 (Japan); Faculty of Science and Technology, Seikei University, Musashino-shi, Tokyo 180-8633 (Japan); Department of Applied Science and Energy Engineering, School of Engineering, Tokai University, Hiratsuka-shi, Kanagawa 259-1292 (Japan); School of Medicine, Shimane University, Izumo-shi, Shimane 693-8501 (Japan)

    2012-11-12

    An ultra-high-energy neutrino (UHE{nu}) gives temperature rise along the hadronic and electromagnetic shower when it enters into rock salt or ice. Permittivities of them arise with respect the temperatures at ionization processes of the UHE{nu} shower. It is expected by Fresnel's formula that radio wave reflects at the irregularity of the permittivity in the medium. We had found the radio wave reflection effect in rock salt. The reflection effect and long attenuation length of radio wave in rock salt and ice would yield a new UHE{nu} detection method. An experiment for ice was performed to study the reflection effect. A coaxial tube was filled with rock salt powder or ice. Open end of the coaxial tube was irradiated by a 2 MeV electron beam. Radio wave of 435 MHz was introduced to the coaxial tube. We measured the reflection wave from the open end. We found the radio wave reflection effect due to electron beam irradiation in ice as well as in rock salt.

  4. Effect of tempering on hardness improvement in a VC/steel surface-alloyed material fabricated by high-energy electron-beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Euh, Kwangjun; Kim, Yong Chan; Shin, Keesam; Lee, Sunghak; Kim, Nack J

    2003-04-15

    The present study is concerned with the tempering effect in improving the hardness of a vanadium carbide (VC)/carbon steel surface-alloyed material fabricated by high-energy electron-beam irradiation. The mixture of VC powders and flux (50%MgO-50%CaO) was placed on a plain carbon steel substrate, and then electron beam was irradiated. The surface-alloyed layer of 1.8 mm in thickness was homogeneously formed without defects. The microstructural analysis indicated that coarse VC particles were formed along solidification cell boundaries, and the matrix inside cells was mostly composed of lath-type martensite and fine cuboidal VC particles. A large amount of these VC particles in the lath-type martensitic matrix provided hardness four times greater than that of the substrate. When the VC/steel surface-alloyed material was tempered, fine VC particles precipitated in the tempered martensitic matrix, thereby leading to additional hardness increase. In addition, reduction of residual stress and an increase in fracture toughness could be expected.

  5. Developments in high energy theory

    Indian Academy of Sciences (India)

    High-energy physics; gauge theories; Standard Model; physics beyond the ... elusive goal. The Standard Model describes the electromagnetic, weak and strong interactions, but only unifies the first two. Despite its spectacular success in ex ..... Towards the end of the 1960s, a path-breaking new 'deep inelastic' electron scat-.

  6. Relativistic quantum dynamics in strong fields: Photon emission from heavy, few-electron ions

    Energy Technology Data Exchange (ETDEWEB)

    Fritzsche, S. [Kassel Univ. (Germany). Inst. fuer Physik; Indelicato, P. [Lab. Kastler Brossel, Ecole Normale Superieure et Universite Pierre et Marie Curie, Paris (France); Stoehlker, T. [Frankfurt Univ. (Germany). Inst. fuer Kernphysik

    2005-03-01

    Recent progress in the study of the photon emission from highly-charged heavy ions is reviewed. These investigations show that high-Z ions provide a unique tool for improving the understanding of the electron-electron and electron-photon interaction in the presence of strong fields. Apart from the bound-state transitions, which are accurately described in the framework of quantum electrodynamics, much information has been obtained also from the radiative capture of (quasi-) free electrons by high-Z ions. Many features in the observed spectra hereby confirm the inherently relativistic behavior of even the simplest compound quantum systems in nature. (orig.)

  7. Evaluation of Monte Carlo tools for high energy atmospheric physics

    Directory of Open Access Journals (Sweden)

    C. Rutjes

    2016-11-01

    Full Text Available The emerging field of high energy atmospheric physics (HEAP includes terrestrial gamma-ray flashes, electron–positron beams and gamma-ray glows from thunderstorms. Similar emissions of high energy particles occur in pulsed high voltage discharges. Understanding these phenomena requires appropriate models for the interaction of electrons, positrons and photons of up to 40 MeV energy with atmospheric air. In this paper, we benchmark the performance of the Monte Carlo codes Geant4, EGS5 and FLUKA developed in other fields of physics and of the custom-made codes GRRR and MC-PEPTITA against each other within the parameter regime relevant for high energy atmospheric physics. We focus on basic tests, namely on the evolution of monoenergetic and directed beams of electrons, positrons and photons with kinetic energies between 100 keV and 40 MeV through homogeneous air in the absence of electric and magnetic fields, using a low energy cutoff of 50 keV. We discuss important differences between the results of the different codes and provide plausible explanations. We also test the computational performance of the codes. The Supplement contains all results, providing a first benchmark for present and future custom-made codes that are more flexible in including electrodynamic interactions.

  8. Constraints on photon pulse duration from longitudinal electron beam diagnostics at a soft x-ray free-electron laser

    Directory of Open Access Journals (Sweden)

    C. Behrens

    2012-03-01

    Full Text Available The successful operation of x-ray free-electron lasers (FELs, like the Linac Coherent Light Source or the Free-Electron Laser in Hamburg (FLASH, makes unprecedented research on matter at atomic length and ultrafast time scales possible. However, in order to take advantage of these unique light sources and to meet the strict requirements of many experiments in photon science, FEL photon pulse durations need to be known and tunable. This can be achieved by controlling the FEL driving electron beams, and high-resolution longitudinal electron beam diagnostics can be utilized to provide constraints on the expected FEL photon pulse durations. In this paper, we present comparative measurements of soft x-ray pulse durations and electron bunch lengths at FLASH. The soft x-ray pulse durations were measured by FEL radiation pulse energy statistics and compared to electron bunch lengths determined by frequency-domain spectroscopy of coherent transition radiation in the terahertz range and time-domain longitudinal phase space measurements. The experimental results, theoretical considerations, and simulations show that high-resolution longitudinal electron beam diagnostics provide reasonable constraints on the expected FEL photon pulse durations. In addition, we demonstrated the generation of soft x-ray pulses with durations below 50 fs (FWHM after the implementation of the new uniform electron bunch compression scheme used at FLASH.

  9. Pair creation by very high-energy photons in gamma-ray bursts a unified picture for the energetics of GRBs

    CERN Document Server

    Totani, T

    1999-01-01

    The extreme energetics of the gamma-ray burst (GRB) 990123 have revealed that some GRBs emit quite a large amount of energy, and the total energy release from GRBs seems to change from burst to burst by a factor of 10/sup 2/-10/sup $9 3/ as E/sub gamma , iso/~10/sup 52-55/ erg, where E/sub gamma , iso/ is the observed GRB energy when the radiation is isotropic. If all GRBs are triggered by similar events, such a wide dispersion in energy release seems odd. The $9 author proposes a unified picture for the energetics of GRBs, in which all GRB events release roughly the same amount of energy E/sub iso/~10 /sup 55-56/ erg relativistic motion, with the baryon load problem almost resolved. A mild $9 dispersion in the initial Lorentz factor ( Gamma ) results in a difference of E/sub gamma , iso/ by up to a factor of m/sub p//m/sub e/~10/sup 3/. Protons work as `a hidden energy reservoir' of the total GRB energy, and E/sub gamma , $9 iso/ depends on the energy transfer efficiency from protons into electrons (or posit...

  10. High-energy atomic physics

    CERN Document Server

    Drukarev, Evgeny G

    2016-01-01

    This self-contained text introduces readers to the field of high-energy atomic physics - a new regime of photon-atom interactions in which the photon energies significantly exceed the atomic or molecular binding energies, and which opened up with the recent advent of new synchrotron sources. From a theoretical point of view, a small-parameter characteristic of the bound system emerged, making it possible to perform analytic perturbative calculations that can in turn serve as benchmarks for more powerful numerical computations. The first part of the book introduces readers to the foundations of this new regime and its theoretical treatment. In particular, the validity of the small-parameter perturbation expansion and of the lowest-order approximation is critically reviewed. The following chapters then apply these insights to various atomic processes, such as photoionization as a many-body problem, dominant mechanisms for the production of ions at higher energies, Compton scattering and ionization accompanied b...

  11. Performance of the ALICE photon spectrometer PHOS

    Energy Technology Data Exchange (ETDEWEB)

    Conesa, G. [IFIC, Centro Mixto Universidad de Valencia-CSIC, Valencia (Spain) and SUBATECH, Ecole des Mines-CNRS-Universite de Nantes, Nantes (France)]. E-mail: gustavo.conesa@ific.uv.es; Delagrange, H. [SUBATECH, Ecole des Mines-CNRS-Universite de Nantes, Nantes (France); Diaz, J. [IFIC, Centro Mixto Universidad de Valencia-CSIC, Valencia (Spain); Ippolitov, M. [Kurchatov Institute, Moscow (Russian Federation); Kharlov, Y.V. [Institute for High-Energy Physics, Protvino (Russian Federation); Peressounko, D. [Kurchatov Institute, Moscow (Russian Federation); Schutz, Y. [SUBATECH, Ecole des Mines-CNRS-Universite de Nantes, Nantes (France); CERN, Geneva (Switzerland)

    2005-01-21

    We present in this paper the measured characteristics of a 64 lead-tungstate crystal array designed to detect high-energy photons and neutral mesons with the ALICE photon spectrometer PHOS. The array has been tested with electron and charged pion secondary beams delivered by the CERN PS and SPS synchrotrons. Photon energy and {pi}0 invariant mass resolutions are presented. The PHOS particle identification performance for data simulated with the AliRoot package is studied.

  12. Simultaneous production of mixed electron--photon beam in a medical LINAC: A feasibility study.

    Science.gov (United States)

    Khaledi, Navid; Arbabi, Azim; Sardari, Dariush; Mohammadi, Mohammad; Ameri, Ahmad

    2015-06-01

    The electron or photon beams might be used for treatment of tumors. Each beam has its own advantage and disadvantages. Combo beam can increase the advantages. No investigation has been performed for producing simultaneous mixed electron and photon beam. In current study a device has been added to the Medical Linac to produce a mixed photon-electron beam. Firstly a Varian 2300CD head was simulated by MCNP Monte Carlo Code. Two sets of perforated lead sheets with 1 and 2 mm thickness and 0.2, 0.3, and 0.5 cm punches then placed at the top of the applicator holder tray. This layer produces bremsstrahlung x-ray upon impinging fraction electrons on it. The remaining fraction of electrons passes through the holes. The simulation was performed for 10 × 10, 6 × 6, and 4 × 4 cm(2) field size. For 10 × 10 cm(2) field size, among the punched targets, the largest penumbra difference between the depth of 1 and 7 cm was 72%. This difference for photon and electron beams were 31% and 325% respectively. A maximum of 39% photon percentage was produced by 2 mm target with 0.2 cm holes diameter layer. The minimum surface dose value was 4% lesser than pure electron beam. For small fields, unlike the pure electron beam, the PDD, penumbra, and flatness variations were negligible. The advantages of mixing the electron and photon beam is reduction of pure electron's penumbra dependency with the depth, especially for small fields, also decreasing of dramatic changes of PDD curve with irradiation field size. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. Nuclear physics with laser-electron-photons. Developments and perspectives at SPring-8

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Mamoru [Osaka Univ., Ibaraki (Japan). Research Center for Nuclear Physics

    1998-03-01

    By the Compton scattering with ultraviolet laser beam using the 8 GeV electron beam of the SPring-8, the photon beam which is polarized by nearly 100% is obtained in 1-3.5 GeV region. The quark nuclear physics research at this facility is unique in the world, and it is expected that in the experiment at the SPring-8, the collision phenomena of polarized, high energy gamma-ray and the quarks in nucleons and the knockout phenomena of quarks are observed. Also the polarization experiment for clarifying ``the origin of nucleon spin`` has been proposed. Japan can stand at the top in the world in the research of quark nuclear physics with leptons. In the inverse Compton scattering using far infrared laser, the gamma-ray with good directionality of MeV range is obtained, and it will be applied widely to the research on E1 resonance and M1 excitation of atomic nuclei. In this report, the medium energy quark nuclear physics developed at the SPring-8 is outlined, and the nuclear physics which is expected to be developed when the high intensity, high polarization gamma-ray of about 10 MeV is generated is discussed. The detection of s, anti-s components in nucleons, research on baryon deformation and baryon spectra, verification of the Gerasimov, Drell-Hearn law of sum, meson structure, test of quark model by the photolysis of deuterons, dual Ginzburg Landau theory exploration, research on the mass and behavior of mesons in nuclear media are discussed. (K.I.)

  14. Coherent Cerenkov emission from electrons streaming through a photonic crystal

    NARCIS (Netherlands)

    van der Slot, Petrus J.M.

    2014-01-01

    Cerenkov radiation is usually incoherent radiation emitted by charged particles when they pass through a medium with sufficiently high, usually relativistic velocity. It has recently been shown that in photonic crystals Cerenkov emission is possible without a velocity threshold, however emission

  15. Reflection high-energy electron diffraction study of growth and interface formation of the Ga(1-x)In(x)Sb/InAs strained-layer superlattices

    Science.gov (United States)

    Fan, W. C.; Zborowski, J. T.; Golding, T. D.; Shih, H. D.

    1992-01-01

    Reflection high-energy electron diffraction (RHEED) during molecular beam epitaxy is used to study the growth and interface formation of the Ga(1-x)In(x)Sb/InAs (x is not greater than 0.4) strained-layer superlattices (SLSs) on GaSb(100) substrates. A number of surface atomic structures were observed in the growth of the SLS: a (1 x 3) phase from the InAs epilayer surface, a (2 x 3) phase, a (2 x 4) phase, and diffuse (1 x 1)-like phases from the InAs epilayer surface. It is suggested that the long-range order quality of the interface of Ga(1-x)In(x)Sb on InAs may be better than that of the interface of InAs on Ga(1-x)In(x)Sb, but the abruptness of the interfaces would still be compatible. The RHEED intensity variations in the formation of the interfaces are discussed in terms of interface chemical reactions.

  16. High energy physics

    Energy Technology Data Exchange (ETDEWEB)

    Kernan, A.; Shen, B.C.; Ma, E.

    1997-07-01

    This proposal is for the continuation of the High Energy Physics program at the University of California at Riverside. In hadron collider physics the authors will complete their transition from experiment UA1 at CERN to the DZERO experiment at Fermilab. On experiment UA1 their effort will concentrate on data analysis at Riverside. At Fermilab they will coordinate the high voltage system for all detector elements. They will also carry out hardware/software development for the D0 muon detector. The TPC/Two-Gamma experiment has completed its present phase of data-taking after accumulating 160 pb{sup {minus}}1 of luminosity. The UC Riverside group will continue data and physics analysis and make minor hardware improvement for the high luminosity run. The UC Riverside group is participating in design and implementation of the data acquisition system for the OPAL experiment at LEP. Mechanical and electronics construction of the OPAL hadron calorimeter strip readout system is proceeding on schedule. Data analysis and Monte Carlo detector simulation efforts are proceeding in preparation for the first physics run when IEP operation comenses in fall 1989.

  17. In situ electrical and thermal monitoring of printed electronics by two-photon mapping

    DEFF Research Database (Denmark)

    Pastorelli, Francesco; Accanto, Nicolo; Jørgensen, Mikkel

    2017-01-01

    Printed electronics is emerging as a new, large scale and cost effective technology that will be disruptive in fields such as energy harvesting, consumer electronics and medical sensors. The performance of printed electronic devices relies principally on the carrier mobility and molecular packing......-destructive and low-cost testing method is needed. In this study, we demonstrate that nonlinear optical microscopy is a promising technique to achieve this goal. Using ultrashort laser pulses we stimulate two-photon absorption in a roll coated polymer semiconductor and map the resulting two-photon induced...

  18. Investigation of DNA nucleobases-thin films for potential application in electronics and photonics

    Science.gov (United States)

    Ouchen, Fahima; Gomez, Eliot; Joyce, Donna; Yaney, Perry; Kim, Steve; Williams, Adrienne; Steckl, Andrew; Venkat, Narayanan; Grote, James

    2013-10-01

    In previous research we have demonstrated improvements in device performance with the incorporation of a deoxyribonucleic acid (DNA)-based biopolymer into organic light emitting diodes, organic thin film transistors and other organic photonic and electronic devices. Here, we investigate nucleobases, nitrogen-containing biological compounds found within DNA, ribonucleic acid (RNA), nucleotides and nucleosides, for use in a few of those previously investigated photonic and electronic devices. Used as an electron blocking layer in OLEDs, a gate insulator for grapheme transistors and as a dielectric in organic-based capacitors, we have produced comparable results to those using DNA-based biopolymers.

  19. Monolithic nanoscale photonics-electronics integration in silicon and other group IV elements

    CERN Document Server

    Radamson, Henry

    2014-01-01

    Silicon technology is evolving rapidly, particularly in board-to-board or chip-to chip applications. Increasingly, the electronic parts of silicon technology will carry out the data processing, while the photonic parts take care of the data communication. For the first time, this book describes the merging of photonics and electronics in silicon and other group IV elements. It presents the challenges, the limitations, and the upcoming possibilities of these developments. The book describes the evolution of CMOS integrated electronics, status and development, and the fundamentals of silicon p

  20. Characteristics of electrons emitted from aluminium, carbon and mylar slabs irradiated by photons

    Energy Technology Data Exchange (ETDEWEB)

    Malbert, M.; Terrissol, M.; Patau, J.P. (Toulouse-3 Univ., 31 (France). Centre de Physique Atomique); Angles, M. (CEG, 46 - Gramat (France))

    1982-01-01

    The forward and backscattered electron fluence emitted by a slab under photon irradiation have been calculated using Monte-Carlo techniques for aluminium, carbon and mylar. The simulation methods used and the techniques chosen to study the low energy (< 30 keV) electron transport are presented. The agreement with experimental and other theoretical results is good.

  1. High Energy Particles from the Universe

    CERN Document Server

    Ong, R A

    2000-01-01

    The field of high energy particle astronomy is exciting and rapidly developing. In the last few years, we have detected extragalactic sources of intense TeV gamma radiation and individual cosmic ray particles with energies exceeding 25 Joules. Understanding the workings of astrophysics under extreme conditions is the primary goal of this field. Also important is the possibility of using high energy particles from space to probe beyond the standard models of particle physics and cosmology. This paper presents a review of high energy particle astronomy using photons, cosmic rays, and neutrinos.

  2. Radiolysis ob benzene, toluene and phenol aqueous solutions utilizing high energy electron beam; Radiolisis de benceno, tolueno y fenol en solucion acuosa utilizando haces de electrones

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Vanderhaghen, D.E

    1998-12-31

    In a search for solutions to environmental pollution problems, radiolysis has proved to be an innovative technique for the removal of organic chemical pollutants in aqueous solution. Radiolysis has shown many advantages over many other techniques, as highly reactive species formed in water by ionizing radiation oxidize organic pollutants breaking down organic molecules to final simple products by oxidation to carbon dioxide and water in a complete oxidation. Our work consisted in doing some experiments in radiolysis with simulated polluted water to help us understand this technique and also develop, in a near future, a project for large scale water treatment. Our project includes the application of a Pelletron type Mexican made Electron Accelerator, which will affirm its capability and usefulness in performing investigation in this field of study. Experiments consisted in treating benzene, toluene and phenol aqueous solutions with an Electron Beam (0.48-0.55 MeV; 24 {mu}A). Two concentrations were used for each compound: 5 and 20 ppm (mg/l) for benzene and toluene; 10 and 50 ppm for phenol. Solutions were prepared with pure, mineral free water and two different p H (5.9), in order to study the effect of concentration and p H on removal efficiency, but avoiding the interference of radical scavengers. Results obtained coincide with the ones reported by Cooper, Nickelsen and Kurucz; highly efficient removal was achieved for benzene (>99.8%), toluene (>98.0%) and phenol (>88%). There was no visible important effect of p H on radiolysis efficiency for benzene nor toluene, phenol however, showed lower removal efficiency in acidic conditions. Concentration of aqueous solutions, nevertheless, did show an important effect at low doses for phenol. Results obtained reveal the importance of this technique in water pollution control and water remedial as expressed by Cooper, Nickelsen and Kurucz, who have studied radiolysis of organic compounds and apply this technique in water

  3. Thermoluminescence Response of Ge-Doped Cylindrical-, Flat- and Photonic Crystal Silica-Fibres to Electron and Photon Radiation.

    Science.gov (United States)

    Entezam, A; Khandaker, M U; Amin, Y M; Ung, N M; Bradley, D A; Maah, J; Safari, M J; Moradi, F

    2016-01-01

    Study has been made of the thermoluminescence (TL) response of silica-based Ge-doped cylindrical, flat and photonic crystal fibres (referred to herein as PCF-collapsed) to electron (6, 12 and 20 MeV) and photon (6, 10 MV) irradiation and 1.25 MeV γ-rays, for doses from 0.1 Gy to 100 Gy. The electron and photon irradiations were delivered through use of a Varian Model 2100C linear accelerator located at the University of Malaya Medical Centre and γ-rays delivered from a 60Co irradiator located at the Secondary Standard Dosimetry Laboratory (SSDL), Malaysian Nuclear Agency. Tailor-made to be of various dimensions and dopant concentrations (6-10% Ge), the fibres were observed to provide TL yield linear with radiation dose, reproducibility being within 1-5%, with insensitivity to energy and angular variation. The sensitivity dependency of both detectors with respect to field size follows the dependency of the output factors. For flat fibres exposed to 6 MV X-rays, the 6% Ge-doped fibre provided the greatest TL yield while PCF-collapsed showed a response 2.4 times greater than that of the 6% Ge-doped flat fibres. The response of cylindrical fibres increased with core size. The fibres offer uniform response, high spatial resolution and sensitivity, providing the basis of promising TL systems for radiotherapy applications.

  4. Quantum State Transfer from a Single Photon to a Distant Quantum-Dot Electron Spin.

    Science.gov (United States)

    He, Yu; He, Yu-Ming; Wei, Yu-Jia; Jiang, Xiao; Chen, Kai; Lu, Chao-Yang; Pan, Jian-Wei; Schneider, Christian; Kamp, Martin; Höfling, Sven

    2017-08-11

    Quantum state transfer from flying photons to stationary matter qubits is an important element in the realization of quantum networks. Self-assembled semiconductor quantum dots provide a promising solid-state platform hosting both single photon and spin, with an inherent light-matter interface. Here, we develop a method to coherently and actively control the single-photon frequency bins in superposition using electro-optic modulators, and measure the spin-photon entanglement with a fidelity of 0.796±0.020. Further, by Greenberger-Horne-Zeilinger-type state projection on the frequency, path, and polarization degrees of freedom of a single photon, we demonstrate quantum state transfer from a single photon to a single electron spin confined in an InGaAs quantum dot, separated by 5 m. The quantum state mapping from the photon's polarization to the electron's spin is demonstrated along three different axes on the Bloch sphere, with an average fidelity of 78.5%.

  5. Quantum State Transfer from a Single Photon to a Distant Quantum-Dot Electron Spin

    Science.gov (United States)

    He, Yu; He, Yu-Ming; Wei, Yu-Jia; Jiang, Xiao; Chen, Kai; Lu, Chao-Yang; Pan, Jian-Wei; Schneider, Christian; Kamp, Martin; Höfling, Sven

    2017-08-01

    Quantum state transfer from flying photons to stationary matter qubits is an important element in the realization of quantum networks. Self-assembled semiconductor quantum dots provide a promising solid-state platform hosting both single photon and spin, with an inherent light-matter interface. Here, we develop a method to coherently and actively control the single-photon frequency bins in superposition using electro-optic modulators, and measure the spin-photon entanglement with a fidelity of 0.796 ±0.020 . Further, by Greenberger-Horne-Zeilinger-type state projection on the frequency, path, and polarization degrees of freedom of a single photon, we demonstrate quantum state transfer from a single photon to a single electron spin confined in an InGaAs quantum dot, separated by 5 m. The quantum state mapping from the photon's polarization to the electron's spin is demonstrated along three different axes on the Bloch sphere, with an average fidelity of 78.5%.

  6. The two-photon exchange contribution to elastic electron-nucleon scattering at large momentum transfer

    Energy Technology Data Exchange (ETDEWEB)

    Andrei V. Afanasev; Stanley J. Brodsky; Carl E. Carlson; Yu-Chun Chen; Marc Vanderhaeghen

    2005-01-01

    We estimate the two-photon exchange contribution to elastic electron-proton scattering at large momentum transfer by using a quark-parton representation of virtual Compton scattering. We thus can relate the two-photon exchange amplitude to the generalized parton distributions which also enter in other wide angle scattering processes. We find that the interference of one- and two-photon exchange contribution is able to substantially resolve the difference between electric form factor measurements from Rosenbluth and polarization transfer experiments.

  7. A New Approach of Electronics and Photonics Convergence on Si CMOS Platform: How to Reduce Device Diversity of Photonics for Integration

    Directory of Open Access Journals (Sweden)

    Kazumi Wada

    2008-01-01

    Full Text Available Integrated photonics via Si CMOS technology has been a strategic area since electronics and photonics convergence should be the next platform for information technology. The platform is recently referred to as “Si photonics” that attracts much interest of researchers in industries as well as academia in the world. The main goal of Si Photonics is currently to reduce material diversity of photonic devices to pursuing CMOS-compatibility. In contrast, the present paper proposes another route of Si Photonics, reducing diversity of photonic devices. The proposed device unifying functionality of photonics is a microresonator with a pin diode structure that enables the Purcell effect and Franz-Keldysh effect to emit and to modulate light from SiGe alloys.

  8. Entanglement transfer from electrons to photons in quantum dots: an open quantum system approach.

    Science.gov (United States)

    Budich, Jan C; Trauzettel, Björn

    2010-07-09

    We investigate entanglement transfer from a system of two spin-entangled electron-hole pairs, each placed in a separate single mode cavity, to the photons emitted due to cavity leakage. Dipole selection rules and a splitting between the light hole and the heavy hole subbands are the crucial ingredients establishing a one-to-one correspondence between electron spins and circular photon polarizations. To account for the measurement of the photons as well as dephasing effects, we choose a stochastic Schrödinger equation and a conditional master equation approach, respectively. The influence of interactions with the environment as well as asymmetries in the coherent couplings on the photon entanglement is analysed for two concrete measurement schemes. The first one is designed to violate the Clauser-Horne-Shimony-Holt (CHSH) inequality, while the second one employs the visibility of interference fringes to prove the entanglement of the photons. Because of the spatial separation of the entangled electronic system over two quantum dots, a successful verification of entangled photons emitted by this system would imply the detection of nonlocal spin entanglement of massive particles in a solid state structure.

  9. Design of the experimental apparatus to obtain a thermal neutron beam, intermediate-energy neutrons (2-144 keV) and high-energy photons (6 MeV) by means of the TRIGA reactor at the ENEA Casaccia center

    CERN Document Server

    Laitano, R F

    1987-01-01

    Design of the experimental apparatus to obtain a thermal neutron beam, intermediate-energy neutrons (2-144 keV) and high-energy photons (6 MeV) by means of the TRIGA reactor at the ENEA Casaccia center

  10. PENELOPE, an algorithm and computer code for Monte Carlo simulation of electron-photon showers

    Energy Technology Data Exchange (ETDEWEB)

    Salvat, F.; Fernandez-Varea, J.M.; Baro, J.; Sempau, J.

    1996-07-01

    The FORTRAN 77 subroutine package PENELOPE performs Monte Carlo simulation of electron-photon showers in arbitrary for a wide energy range, from 1 keV to several hundred MeV. Photon transport is simulated by means of the standard, detailed simulation scheme. Electron and positron histories are generated on the basis of a mixed procedure, which combines detailed simulation of hard events with condensed simulation of soft interactions. A simple geometry package permits the generation of random electron-photon showers in material systems consisting of homogeneous bodies limited by quadric surfaces, i.e. planes, spheres, cylinders, etc. This report is intended not only to serve as a manual of the simulation package, but also to provide the user with the necessary information to understand the details of the Monte Carlo algorithm. (Author) 108 refs.

  11. PENELOPE, and algorithm and computer code for Monte Carlo simulation of electron-photon showers

    Energy Technology Data Exchange (ETDEWEB)

    Salvat, F.; Fernandez-Varea, J.M.; Baro, J.; Sempau, J.

    1996-10-01

    The FORTRAN 77 subroutine package PENELOPE performs Monte Carlo simulation of electron-photon showers in arbitrary for a wide energy range, from similar{sub t}o 1 KeV to several hundred MeV. Photon transport is simulated by means of the standard, detailed simulation scheme. Electron and positron histories are generated on the basis of a mixed procedure, which combines detailed simulation of hard events with condensed simulation of soft interactions. A simple geometry package permits the generation of random electron-photon showers in material systems consisting of homogeneous bodies limited by quadric surfaces, i.e. planes, spheres cylinders, etc. This report is intended not only to serve as a manual of the simulation package, but also to provide the user with the necessary information to understand the details of the Monte Carlo algorithm.

  12. Conversion from Single Photon to Single Electron Spin Using Electrically Controllable Quantum Dots

    Science.gov (United States)

    Oiwa, Akira; Fujita, Takafumi; Kiyama, Haruki; Allison, Giles; Ludwig, Arne; Wieck, Andreas D.; Tarucha, Seigo

    2017-01-01

    Polarization is a fundamental property of light and could provide various solutions to the development of secure optical communications with high capacity and high speed. In particular, the coherent quantum state conversion between single photons and single electron spins is a prerequisite for long-distance quantum communications and distributed quantum computation. Electrically defined quantum dots have already been proven to be suitable for scalable solid state qubits by demonstrations of single-spin coherent manipulations and two-qubit gate operations. Thus, their capacity for quantum information technologies would be considerably extended by the achievement of entanglement between an electron spin in the quantum dots and a photon. In this review paper, we show the basic technologies for trapping single electrons generated by single photons in quantum dots and for detecting their spins using the Pauli effect with sensitive charge sensors.

  13. 3D electron tomography of biological photonic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Butz, Benjamin; Winter, Benjamin; Vieweg, Benito; Knoke, Isabel; Spallek, Stefanie; Spiecker, Erdmann [CENEM, Universitaet Erlangen-Nuernberg (Germany); Schroeder-Turk, Gerd; Mecke, Klaus [Theoretische Physik I, Universitaet Erlangen-Nuernberg (Germany)

    2011-07-01

    Photonic crystals, i.e. periodical nanostructures of materials with different dielectric constants, are highly interesting for applications in optics, optoelectronics, and sensing. By tailoring the geometrical parameters radically different and improved optical properties (e.g., optical band-gap structure, extreme refractive indices, or high anisotropy) can be achieved. Naturally occurring photonic crystals, like butterfly scales, exoskeletons of insects (chitin), or seashells (nacre), can serve as model systems for understanding the relationship between structure and optical properties. Butterfly scales are studied by TEM using a FEI Titan{sup 3} 80-300 instrument. An optimized FIB technique or ultramicrotome sectioning were used to prepare the sensitive specimens with desired thickness. Since the periodical structures have dimensions on the sub-{mu}m scale, HAADF-STEM tomography was employed for obtaining extended tilt series under conditions of atomic-number sensitive imaging. Since the solid crystal consists of chemically homogeneous chitin while the pores are unfilled, the distinct contrast in the images can easily be interpreted in terms of the local projected mass density allowing to reconstruct the chitin distribution within the optical unit cell of the scales with high 3D resolution.

  14. Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom.

    Science.gov (United States)

    Bazalova-Carter, Magdalena; Liu, Michael; Palma, Bianey; Dunning, Michael; McCormick, Doug; Hemsing, Erik; Nelson, Janice; Jobe, Keith; Colby, Eric; Koong, Albert C; Tantawi, Sami; Dolgashev, Valery; Maxim, Peter G; Loo, Billy W

    2015-04-01

    To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0-6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4-6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0-4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. The authors demonstrate that relative dose distributions for VHEE beams of 50-70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

  15. FinalReport for completed IPP-0110 and 0110A Projects:"High Energy Ion Technology of Interfacial Thin Film Coatings for Electronic, Optical and Industrial Applications"

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Ian

    2009-09-01

    The DOE-supported IPP (Initiatives for Proliferation Prevention) Project, IPP-0110, and its accompanying 'add-on project' IPP-0110A, entitled 'High Energy Ion Technology of Interfacial Thin Film Coatings for Electronic, Optical and Industrial Applications' was a collaborative project involving the Lawrence Berkeley National Laboratory (LBNL) as the U.S. DOE lab; the US surface modification company, Phygen, Inc., as the US private company involved; and the High Current Electronics Institute (HCEI) of the Russian Academy of Sciences, Tomsk, Siberia, Russia, as the NIS Institute involved. Regular scientific research progress meetings were held to which personnel came from all participating partners. The meetings were held mostly at the Phygen facilities in Minneapolis, Minnesota (with Phygen as host) with meetings also held at Tomsk, Russia (HCEI as host), and at Berkeley, California (LBNL as host) In this way, good exposure of all researchers to the various different laboratories involved was attained. This report contains the Final Reports (final deliverables) from the Russian Institute, HCEI. The first part is that for IPP-0110A (the 'main part' of the overall project) and the second part is that for the add-on project IPP-0110A. These reports are detailed, and contain all aspects of all the research carried out. The project was successful in that all deliverables as specified in the proposals were successfully developed, tested, and delivered to Phygen. All of the plasma hardware was designed, made and tested at HCEI, and the performance was excellent. Some of the machine and performance parameters were certainly of 'world class'. The goals and requirements of the IPP Project were well satisfied. I would like to express my gratitude to the DOE IPP program for support of this project throughout its entire duration, and for the unparalleled opportunity thereby provided for all of the diverse participants in the project to join

  16. SU-E-T-238: Deriving Electron Contamination Spectra From Pure and Clinical Photon Beams

    Energy Technology Data Exchange (ETDEWEB)

    Smit, C; Plessis, F du [University of the Free State, Bloemfontein, Free State (South Africa)

    2015-06-15

    Purpose: To extract the electron contamination energy spectra for an Elekta Precise Linac, based on pure photon and measured clinical beam percentage depth dose data. And to include this as an additional source in isource 4 in DOSXYZnrc. Methods: A pure photon beam was simulated for the Linac using isource 4 in the DOSXYZnrc Monte Carlo (MC) code. Percentage depth dose (PDD) data were extracted afterwards for a range of field sizes (FS). These simulated dose data were compared to actual measured dose PDD data, with the data normalized at 10 cm depth. The resulting PDD data resembled the electron contamination depth dose. Since the dose fall-off is a strictly decreasing function, a method was adopted to derive the contamination electron spectrum. Afterwards this spectrum was used in a DOSXYZnrc MC simulation run to verify that the original electron depth dose could be replicated. Results: Various square aperture FS’s for 6, 8 and 15 megavolt (MV) photon beams were modeled, simulated and compared to their respective actual measured PDD data. As FS increased, simulated pure photon depth-dose profiles shifted deeper, thus requiring electron contamination to increase the surface dose. The percentage of electron weight increased with increase in FS. For a FS of 15×15 cm{sup 2}, the percentage electron weight is 0.1%, 0.2% and 0.4% for 6, 8 and 15 MV beams respectively. Conclusion: From the PDD results obtained, an additional electron contamination source was added to the photon source model so that simulation and measured PDD data could match within 2 % / 2 mm gamma-index criteria. The improved source model could assure more accurate simulations of surface doses. This research project was funded by the South African Medical Research Council (MRC) with funds from National Treasury under its Economic Competitiveness and Support package.

  17. Electron angular distributions in two-photon double ionization of helium

    Energy Technology Data Exchange (ETDEWEB)

    Makris, M.G. [Univ. of Crete, Physics Dept., Heraklion (Greece); Nikolopoulos, L.A.A. [Inst. of Electronic Structure and Laser, Forth, Heraklion, Crete (Greece); Lambropoulos, P. [Univ. of Crete, Physics Dept., Heraklion (Greece); Inst. of Electronic Structure and Laser, Forth, Heraklion, Crete (Greece)

    2001-06-15

    We present photoelectron angular distributions (PAD) in two-photon double ionization of helium for photon energies in the range of 45 eV, where the direct double ejection is unequivocally distinguishable from the sequential. Through an approach that allows us to explore the role of correlation, we obtain conditions under which the two electrons have the tendency to be emitted in the same direction. Relevant experiments should be feasible either using high-order harmonic generation or the upcoming short-wavelength free electron laser sources. (orig.)0.

  18. Wave Propagation From Electrons to Photonic Crystals and Left-Handed Materials

    CERN Document Server

    Markos, Peter

    2010-01-01

    This textbook offers the first unified treatment of wave propagation in electronic and electromagnetic systems and introduces readers to the essentials of the transfer matrix method, a powerful analytical tool that can be used to model and study an array of problems pertaining to wave propagation in electrons and photons. It is aimed at graduate and advanced undergraduate students in physics, materials science, electrical and computer engineering, and mathematics, and is ideal for researchers in photonic crystals, negative index materials, left-handed materials, plasmonics, nonlinear effects,

  19. Introduction to Radiotherapy with Photon and Electron Beams and Treatment Planning from Conformal Radiotherapy to IMRT

    Science.gov (United States)

    Wilkens, Jan J.

    2007-11-01

    Besides surgery and chemotherapy, radiation therapy is one of the three main treatment options for cancer patients. This paper provides an introduction to the basic principles of radiotherapy with photons and electrons. It includes a brief summary of the physical properties for photon and electron beams as well as a description of treatment machines used to create these beams. The second part introduces the treatment planning process as it is commonly employed in radiotherapy. It covers dose calculation algorithms, conventional planning strategies for three-dimensional conformal radiotherapy, and optimization techniques for intensity modulated radiotherapy (IMRT).

  20. Search for New Physics in Electron-Positron Interactions with Photons in the Final State

    CERN Document Server

    Ruschmeier, D

    1999-01-01

    This thesis describes a measurement of single and multi-photon events with missing energy in electron-positron interactions. The results have been used to measure the neutrino pair-production cross section and to determine the number of light neutrino species. A search for various kinds of new physics processes involving photons and missing energy in the final state like the production of supersymmetric particles, a fermiophobic Higgs boson and massive gravitons has been carried out. The analysis has been performed using data collected with the L3 detector at LEP at centre-of-mass energies between 130 GeV and 190 GeV corresponding to a total luminosity of 265 1/pb. The cross section of the process electron positron to neutrino anti-neutrino photon (photon) for a photon energy larger than 5 GeV and a photon scattering angle with respect to the beam axis larger than 14 degrees at a centre-of-mass energy of 189 GeV has been measured to be (5.25 +- 0.22 +- 0.07) pb and has been extrapolated to a total cross secti...

  1. Precision timing calorimeter for high energy physics

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Dustin; Apresyan, Artur [California Institute of Technology, Pasadena, CA 91125 (United States); Bornheim, Adolf, E-mail: bornheim@hep.caltech.edu [California Institute of Technology, Pasadena, CA 91125 (United States); Duarte, Javier; Peña, Cristián; Spiropulu, Maria; Trevor, Jason; Xie, Si [California Institute of Technology, Pasadena, CA 91125 (United States); Ronzhin, Anatoly [Fermi National Accelerator Laboratory, PO Box 500, Batavia, IL 60510-5011 (United States)

    2016-07-11

    Scintillator based calorimeter technology is studied with the aim to achieve particle detection with a time resolution on the order of a few 10 ps for photons and electrons at energies of a few GeV and above. We present results from a prototype of a 1.4×1.4×11.4 cm{sup 3} sampling calorimeter cell consisting of tungsten absorber plates and Cerium-doped Lutetium Yttrium Orthosilicate (LYSO) crystal scintillator plates. The LYSO plates are read out with wave lengths shifting fibers which are optically coupled to fast photo detectors on both ends of the fibers. The measurements with electrons were performed at the Fermilab Test Beam Facility (FTBF) and the CERN SPS H2 test beam. In addition to the baseline setup plastic scintillation counter and a MCP-PMT were used as trigger and as a reference for a time of flight measurement (TOF). We also present measurements with a fast laser to further characterize the response of the prototype and the photo sensors. All data were recorded using a DRS4 fast sampling digitizer. These measurements are part of an R&D program whose aim is to demonstrate the feasibility of building a large scale electromagnetic calorimeter with a time resolution on the order of 10 ps, to be used in high energy physics experiments.

  2. Precision timing calorimeter for high energy physics

    Science.gov (United States)

    Anderson, Dustin; Apresyan, Artur; Bornheim, Adolf; Duarte, Javier; Peña, Cristián; Spiropulu, Maria; Trevor, Jason; Xie, Si; Ronzhin, Anatoly

    2016-07-01

    Scintillator based calorimeter technology is studied with the aim to achieve particle detection with a time resolution on the order of a few 10 ps for photons and electrons at energies of a few GeV and above. We present results from a prototype of a 1.4×1.4×11.4 cm3 sampling calorimeter cell consisting of tungsten absorber plates and Cerium-doped Lutetium Yttrium Orthosilicate (LYSO) crystal scintillator plates. The LYSO plates are read out with wave lengths shifting fibers which are optically coupled to fast photo detectors on both ends of the fibers. The measurements with electrons were performed at the Fermilab Test Beam Facility (FTBF) and the CERN SPS H2 test beam. In addition to the baseline setup plastic scintillation counter and a MCP-PMT were used as trigger and as a reference for a time of flight measurement (TOF). We also present measurements with a fast laser to further characterize the response of the prototype and the photo sensors. All data were recorded using a DRS4 fast sampling digitizer. These measurements are part of an R&D program whose aim is to demonstrate the feasibility of building a large scale electromagnetic calorimeter with a time resolution on the order of 10 ps, to be used in high energy physics experiments.

  3. Reflection high-energy electron diffraction studies of indium phosphide (100) and growth on indium and indium nitride on silicon (100)

    Science.gov (United States)

    Hafez, Mohamed Abd-Elsattar

    Study of the effects of atomic hydrogen exposure on structure and morphology of semiconductor surfaces is important for fundamental properties and applications. In this dissertation, the electron yield of a hydrogen-cleaned indium phosphide (InP) surface was measured and correlated to the development of the surface morphology, which was monitored by in situ reflection high-energy electron diffraction (RHEED). Atomic hydrogen treatment produced a clean, well-ordered, and (2x4)-reconstructed InP(100) surface. The quantum efficiency, after activation to negative electron affinity, and the secondary electron emission were shown to increase with hydrogen cleaning time. RHEED patterns of low-index InP(100) surface were modified by the step structure and resulted in splitting of the specular beam at the out-of-phase diffraction condition. Quantitative RHEED showed reduction in the average terrace width and a decrease of the adatom-vacancy density with hydrogen exposure. This suggests that atomic hydrogen etching occurs preferentially at terrace edges, and thermal diffusion on the surface causes changes in the terrace edge morphology, which result in the observed decrease in the average terrace width. The results show that the decrease in the surface disorder, measured from the RHEED intensity-to-background ratio, correlated with the increased quantum efficiency. The growth of group-III metals on Si surfaces has become an attractive area of research because of its scientific importance and great potential in technological applications. In this work, the growth dynamics, structure, and morphology of indium (In) on a vicinal Si(100)-(2x1) surface by femtosecond pulsed laser deposition (fsPLD) were studied using in situ RHEED and ex situ atomic force microscopy. Indium was found to grow on Si(100) by the Stranski-Krastanove mode. At room temperature, the initial growth formed strained two-dimensional (2D) layers in the In(2x1) structure followed by growth of three

  4. Detection of Infrared Photons Using the Electronic Stress in Metal-Semiconductor Interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Datskos, P.G.; Datskou, I.; Egert, C.M.; Rjic, S.

    1999-04-05

    It is well known that the work function of metals decreases when they are placed in a nonpolar liquid. A similar decrease occurs when the metal is placed into contact with a semiconductor forming a Schottky barrier. We report on a new method for detecting photons using the stress caused by photo-electrons emitted from a metal film surface in contact with a semiconductor microstructure. The photoelectrons diffuse into the microstructure and produce an electronic stress. The photon detection results from the measurement of the photo-induced bending of the microstructure. Internal photoemission has been used in the past to detect photons, however, in those cases the detection was accomplished by measuring the current due to photoelectrons and not due to electronic stress. Small changes in position (displacement) of microstructures are routinely measured in atomic force microscopy (AFM) where atomic imaging of surfaces relies on the measurement of small changes (< l0{sup -9} m) in the bending of microcantilevers. In the present work we studied the photon response of Si microcantilevers coated with a thin film of Pt. The Si microcantilevers were 500 nm thick and had a 30 nm layer of Pt. Photons with sufficient energies produce electrons from the platinum-silicon interface which diffuse into the Si and produce an electronic stress. Since the excess charge carriers cause the Si microcantilever to contract in length but not the Pt layer, the bimaterial microcantilever bends. In our present studies we used the optical detection technique to measure the photometric response of Pt-Si microcantilevers as a function of photon energy. The charge carriers responsible for the photo-induced stress in Si, were produced via internal photoemission using a diode laser with wavelength {lambda} = 1550 nm.

  5. MEMS-Electronic-Photonic Heterogeneous Integrated FMCW Ladar Source

    Science.gov (United States)

    2015-12-18

    flip -­‐chip   bonding  of   the  CMOS  and   silicon  photonics  dies.  Electrical   and  mechanical...lock  the  beat  signal  to  LO  a  type-­‐II  PLL  should  be  employed.  One  of  the   poles  at  origin...addition  to  the   pole  at  origin,  loop-­‐filter  should  also  include  a  zero  to  provide

  6. Dose delivery accuracy of therapeutic photon and electron beams at low monitor unit settings

    Energy Technology Data Exchange (ETDEWEB)

    Ravikumar, M.; Al Asmary, M.A.; Sultan, R.A.; Al Ghamdi, H.A. [Oncology Center, King Abdul Aziz Hospital and Oncology Center, Jeddah (Saudi Arabia)

    2005-12-01

    Purpose: dose delivery accuracy at low monitor units (LMU) was evaluated for photon and electron beams. Knowledge of this study is required for few dosimetric applications and to know the dose delivered to the patient when the treatment is delivered with few monitor units (MU). Material and methods: dose measurements were carried out for photon and electron beams with 0.6 cm{sup 3} PTW ion chamber in white polystyrene phantom at D{sub max} with a field size of 10 x 10 cm{sup 2} at 100 cm FSD. The relative dose, which is the ratio of dose delivered per MU at the testing to that of the calibration condition, was found out. Results: significant deviation (+20% to +25%) in dose delivery was noticed for photon and electron beams (+39% to +45%) at LMU settings. Slightly higher inaccuracy in dose delivery was noticed for 6-MV compared to 18-MV photons. The deviation in dose delivery for electron beams was found to be energy-independent and the pattern of variation was similar for all electron energies. Conclusion: the dose delivery accuracy at LMU settings has to be ascertained before implementing conformal and IMRT (intensity-modulated radiotherapy) techniques. When there is dose nonlinearity, the treatment delivered with multiple small MU settings can result in significant error in dose delivery. (orig.)

  7. The response of a radiophotoluminescent glass dosimeter in megavoltage photon and electron beams.

    Science.gov (United States)

    Araki, Fujio; Ohno, Takeshi

    2014-12-01

    This study investigated the response of a radiophotoluminescent glass dosimeter (RGD) in megavoltage photon and electron beams. The RGD response was compared with ion chamber measurements for 4-18 MV photons and 6-20 MeV electrons in plastic water phantoms. The response was also calculated via Monte Carlo (MC) simulations with EGSnrc/egs_chamber and Cavity user-codes, respectively. In addition, the response of the RGD cavity was analyzed as a function of field sizes and depths according to Burlin's general cavity theory. The perturbation correction factor, PQ, in the RGD cavity was also estimated from MC simulations for photon and electron beams. The calculated and measured RGD energy response at reference conditions with a 10 × 10 cm(2) field and 10 cm depth in photons was lower by up to 2.5% with increasing energy. The variation in RGD response in the field size range of 5 × 5 cm(2) to 20 × 20 cm(2) was 3.9% and 0.7%, at 10 cm depth for 4 and 18 MV, respectively. The depth dependence of the RGD response was constant within 1% for energies above 6 MV but it increased by 2.6% and 1.6% for a large (20 × 20 cm(2)) field at 4 and 6 MV, respectively. The dose contributions from photon interactions (1 - d) in the RGD cavity, according to Burlin's cavity theory, decreased with increasing energy and decreasing field size. The variation in (1 - d) between field sizes became larger with increasing depth for the lower energies of 4 and 6 MV. PQ for the RGD cavity was almost constant between 0.96 and 0.97 at 10 MV energies and above. Meanwhile, PQ depends strongly on field size and depth for 4 and 6 MV photons. In electron beams, the RGD response at a reference depth, dref, varied by less than 1% over the electron energy range but was on average 4% lower than the response for 6 MV photons. The RGD response for photon beams depends on both (1 - d) and perturbation effects in the RGD cavity. Therefore, it is difficult to predict the energy dependence of RGD response by

  8. Effect of standard deviation, strength of magnetic field and electron density on the photonic band gap of an extrinsic disorder plasma photonic structure

    Science.gov (United States)

    Nayak, Chittaranjan; Aghajamali, Alireza; Scotognella, Francesco; Saha, Ardhendu

    2017-10-01

    Transmission properties of electromagnetic waves within microwave region of the one-dimensional random extrinsic plasma photonic crystals were computed using the transfer matrix method. The layers thicknesses of the extrinsic random photonic structure follow a Gaussian distribution. Compared with the periodic extrinsic photonic crystal, wider photonic band gaps (PBGs) were found in case of random extrinsic plasma photonic crystals with few resonant peaks. The PBGs are much wider while the randomness was increased and the number and the strength of resonant peaks were enhanced. The above observations were confirmed through analysis of histogram of normalized average transmissions for four different values of standard deviation with one thousand random samples for each group. The normalized average transmission was controlled by changing the strength of external magnetic field and the electron density of magnetized cold plasma. These features of disordered extrinsic plasma photonic structures would have potential applications such as omnidirectional reflectors and random multichannel filters with lower and higher rate of disorder.

  9. Synchrotron-Radiation Photon Distributions for Highest Energy Circular Colliders

    CERN Document Server

    Maury Cuna, G H I; Dugan, G; Zimmermann, F

    2013-01-01

    At high energies, beam-induced synchrotron radiation is an important source of heating, beam-related vacuum pressure increase, and primary photoelectrons, which can give rise to an electron cloud. The photon distribution along the beam pipe wall is a key input to codes such as ECLOUD and PyECLOUD, which model the electron cloud build-up. For future high-energy colliders, like TLEP or SHE-LHC, photon stops and antechambers are considered in order to facilitate cooling and vacuum pressure control. We use the Synrad3D code developed at Cornell to simulate the photon distribution for the LHC.

  10. Synchrotron-Radiation Photon Distribution for Highest Energy Circular Colliders

    CERN Document Server

    Maury Cuna, GHI; Dugan, G; Zimmermann, F

    2013-01-01

    At high energies, beam-induced synchrotron radiation is an important source of heating, beam-related vacuum pressure increase, and primary photoelectrons, which can give rise to an electron cloud. The photon distribution along the beam pipe wall is a key input to codes such as ECLOUD and PyECLOUD, which model the electron cloud build-up. For future high-energy colliders, like TLEP or SHE-LHC, photon stops and antechambers are considered in order to facilitate cooling and vacuum pressure control. We use the Synrad3D code developed at Cornell to simulate the photon distribution for the LHC.

  11. On Photon Spin and the Electrodynamic Origin of the charge of the Electron

    CERN Document Server

    Fischer, Ulrich C

    2016-01-01

    We recently performed experiments on the transfer of photon spin to electron orbital angular momentum. For an interpretation of the experimental results we used a classical electrodynamic model of the photon as a propagating electromagnetic solitary wave which is developed in detail here. A linearly polarized monochromatic photon is considered as a propagating solitary electromagnetic wave of finite energy hf which carries an angular momentum h/2pi with the frequency f and Plancks constant h. This model has, apart from being a tool for an interpretation of our experimental results, far reaching consequences of fundamental relevance and guides us to an outline to a unified quantum theory of electromagnetism and gravitation including an explanation of the electrodynamic origin of the quantized charge of an electron.

  12. Strong coupling of a single electron in silicon to a microwave photon

    Science.gov (United States)

    Mi, Xiao; Cady, Jeffrey; Zajac, David; Petta, Jason

    We demonstrate a hybrid circuit quantum electrodynamics (cQED) architecture in which a single electron in a Si/SiGe double quantum dot is dipole-coupled to the electric field of microwave photons in a superconducting cavity. Vacuum Rabi splitting is observed in the cavity transmission when the transition energy of the single-electron charge qubit matches that of a cavity photon, demonstrating that our device is in the strong coupling regime. The achievement of strong coupling is largely facilitated by an exceptionally low charge decoherence rate of 5 MHz and paves the way toward a wide range of cQED experiments with quantum dots, such as non-local qubit interactions, strong spin-cavity coupling and single photon generation . Research sponsored by ARO Grant No. W911NF-15-1-0149, the Gordon and Betty Moore Foundation's EPiQS Initiative through Grant GBMF4535, and the NSF (DMR-1409556 and DMR-1420541).

  13. TU-H-BRC-03: Evaluation of Very High-Energy Electron (VHEE) Beams in Comparison to VMAT and PBS Treatment Plans

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, E; Loo, B; Maxim, P [Stanford University School of Medicine, Palo Alto, California (United States); Eriksson, K; Hynning, E [RaySearch Laboratories, Stockholm (Sweden)

    2016-06-15

    Purpose: The aim of this study was to evaluate the performance of very high-energy electron (VHEE) beams in comparison to clinically delivered treatment plans generated with volumetric modulated arc therapy (VMAT) and proton pencil beam scanning (PBS) technology. Methods: Three clinical cases were selected (prostate, lung, and pediatric CNS). The VHEE plans were calculated in the Monte Carlo EGSnrc code and pencil beam doses were calculated using the DOSxyznrc MC code for 100 and 200 MeV beams. Treatment plans with VHEE, VMAT, and PBS were optimized in a research version of RayStation using an in house build script in order to minimize operator bias between the different techniques. Results: For the prostate cancer case, the PBS plan showed lower mean organ at risk (OAR) doses compared to the other modalities. An exception was the femoral heads, due to the lateral beam arrangements. The VMAT plan showed lower mean doses to the rectum and the bladder compared to the 100 MeV VHEE plan. The lung cancer case showed minor differences between the three modalities. However, the PBS plan showed a lower contralateral lung dose. The pediatric CNS case showed a better conformity and lower spinal cord dose for the 100 MeV VHEE plan. For all cases, the 200 MeV VHEE plans were found to be similar to or better than the 100 MeV VHEE plans. Conclusion: The present study showed that VHEE plans are similar or superior to VMAT plans with reduced mean OAR dose and increased target conformity for a variety of clinical cases. With increased VHEE energy, better conformity and even higher reductions in mean OAR doses can be achieved. Funding: DoD, Award#:W81XWH-13-1-0165, Weston Havens Foundation, Bio-X (Stanford University), the Office of the Dean of the Medical School, the Office of the Provost (Stanford University), and the Swedish Childhood Cancer Foundation. BL and PM are founders of TibaRay,Inc. BL and PM have received research grants from Varian and RaySearch Laboratory.

  14. Experimental Study of Electronic Quantum Interference, Photonic Crystal Cavity, Photonic Band Edge Effects for Optical Amplification

    Science.gov (United States)

    2016-01-26

    wavelength upon fabrication. This wavelength is ideal for strained InGaAs quantum well structures which can be embedded into the GaAs/AlGaAs matrix[3... quantum dot or an InGaAs quantum well . The band gap can be varied in addition to include either one or two electronic levels of a multi-level system...Electronic and Optoelectronic Devices,” SAND99-0921, July 1999. 4. R. L. S. Devine, “Photoluminescence characterization of InGaAs /GaAs quantum well

  15. Convergence of photonics and electronics for Terahertz wireless communications – the ITN CELTA project

    DEFF Research Database (Denmark)

    Tafur Monroy, Idelfonso

    2016-01-01

    Terahertz wireless communications is expected to offer the required high capacity and low latency performance required from short-range wireless access and control applications. We present an overview of some the activities in this area in the newly started H2020 ITN project CELTA: convergence of...... of electronics and photonics technologies enabling Terahertz applications...

  16. Free-Electron Laser-Induced 2-Photon Absorption in Hg1-Xcdxte

    NARCIS (Netherlands)

    Burghoorn, J.; Anderegg, V. F.; Klaassen, T. O.; Wenckebach, W. T.; Bakker, R. J.; van der Meer, A. F. G.; Oepts, D.; van Amersfoort, P. W.

    1992-01-01

    The powerful output of FELIX, the recently built Rijnhuizen free-electron laser, is used for the first frequency dependent study of nonlinear optical excitation of Hg1-xCdxTe in the far-infrared spectral region. Two-photon interband absorption has been investigated as a function of power and

  17. Convergence of photonics and electronics for Terahertz wireless communications – the ITN CELTA project

    DEFF Research Database (Denmark)

    Tafur Monroy, Idelfonso

    2016-01-01

    Terahertz wireless communications is expected to offer the required high capacity and low latency performance required from short-range wireless access and control applications. We present an overview of some the activities in this area in the newly started H2020 ITN project CELTA: convergence...... of electronics and photonics technologies enabling Terahertz applications...

  18. Development of an integrated photonic beamformer for electronically-steered Ku-band phased array antenna

    NARCIS (Netherlands)

    Zhuang, L.; Marpaung, D.A.I.; Burla, M.; Boot, R.; Hulzinga, A.; Beeker, W.P.; Beeker, Willem; van Dijk, P.; Roeloffzen, C.G.H.

    2011-01-01

    Currently an integrated photonic beamformer for electronically-steered Ku-band phased array antenna (PAA) system for satellite communications is being developed within a Dutch Point One R&D Innovation Project “Broadband Satellite Communication Services on High-Speed Transport Vehicles‿, targeting

  19. An analytical method for computing voxel S values for electrons and photons.

    Science.gov (United States)

    Amato, Ernesto; Minutoli, Fabio; Pacilio, Massimiliano; Campenni, Alfredo; Baldari, Sergio

    2012-11-01

    The use of voxel S values (VSVs) is perhaps the most common approach to radiation dosimetry for nonuniform distributions of activity within organs or tumors. However, VSVs are currently available only for a limited number of voxel sizes and radionuclides. The objective of this study was to develop a general method to evaluate them for any spectrum of electrons and photons in any cubic voxel dimension of practical interest for clinical dosimetry in targeted radionuclide therapy. The authors developed a Monte Carlo simulation in Geant4 in order to evaluate the energy deposited per disintegration (E(dep)) in a voxelized region of soft tissue from monoenergetic electrons (10-2000 keV) or photons (10-1000 keV) homogeneously distributed in the central voxel, considering voxel dimensions ranging from 3 mm to 10 mm. E(dep) was represented as a function of a dimensionless quantity termed the "normalized radius," R(n) = R∕l, where l is the voxel size and R is the distance from the origin. The authors introduced two parametric functions in order to fit the electron and photon results, and they interpolated the parameters to derive VSVs for any energy and voxel side within the ranges mentioned above. In order to validate the results, the authors determined VSV for two radionuclides ((131)I and (89)Sr) and two voxel dimensions and they compared them with reference data. A validation study in a simple sphere model, accounting for tissue inhomogeneities, is presented. The E(dep)(R(n)) for both monoenergetic electrons and photons exhibit a smooth variation with energy and voxel size, implying that VSVs for monoenergetic electrons or photons may be derived by interpolation over the range of energies and dimensions considered. By integration, S values for continuous emission spectra from β(-) decay may be derived as well. The approach allows the determination of VSVs for monoenergetic (Auger or conversion) electrons and (x-ray or gamma-ray) photons by means of two functions whose

  20. Duke University high energy physics

    Energy Technology Data Exchange (ETDEWEB)

    Fortney, L.R.; Goshaw, A.T.; Walker, W.D.

    1992-07-01

    This Progress Report presents a review of the research done in 1992 by the Duke High Energy Physics Group. This is the first year of a three-year grant which was approved by the Office of High Energy Physics at DOE after an external review of our research program during the summer of 1991. Our research is centered at Fermilab where we are involved with two active experiments, one using the Tevatron collider (CDF, the Collider Detector Facility) and the other using a proton beam in the high intensity laboratory (E771, study of beauty production). In addition to these running experiments we are continuing the analysis of data from experiments E735 (collider search for a quark-gluon plasma), E705 (fixed target study of direct photon and {sub {Chi}} meson production) and E597 (particle production from hadron-nucleus collisions). Finally, this year has seen an expansion of our involvement with the design of the central tracking detector for the Solenoidal Detector Collaboration (SDC) and an increased role in the governance of the collaboration. Descriptions of these research activities are presented in this report.

  1. SU-E-T-502: Dose Perturbation Effects Near Implant Surfaces Caused by Secondary Electron Transport in Photon-Beam Therapy.

    Science.gov (United States)

    Chofor, N; Poppe, B; Harder, D

    2012-06-01

    To investigate the dose perturbation effects at interfaces between water and a Titanium implant, attributable to secondary electron transport across the interface, during high energy photon radiotherapy. While dose enhancement is characteristic for the proximal interface of a high-atomic number implant, the dose perturbation at the distal interface varies from reduction to enhancement, requiring proper computation of secondary electron transport effects. The backward and forward perturbation factors pb and pf will be calculated. Using DOSRZnrc, depth dose curves were computed in a water phantom using photon spectra of nominal energies 4, 6, 10, 15, 24 MV for conditions (i) homogeneous water without any insert, (ii) alternatively with Titanium inserts of thicknesses 3 and 5 cm placed at 10 cm water depth. Backscatter factor pb was computed as the ratio of the dose with implant against that without implant, whereas pf was calculated by first accounting for photon attenuation in the implant and then taking the ratio of the dose with implant against that without implant. At the front interface, pb is independent of the material thickness and varies slightly with beam energy and incident angle. On consideration of photon attenuation in the implant, pf was also found to be independent on material thickness, but strongly varying with energy, including change of sign. For 4-24 MV photon beams the maximum spread of the dose perturbation effect remains within only a few millimeters from the interface, with pb values ranging from 1.18-1.22, while factor pf ranges from 0.9-1.21 at normal incidence, indicating the extent to which planning systems may over- or underestimate the doses near implant interfaces. At inclined beam incidence the dose perturbation effects even increase, and for instance pb (1.24-1.25) and pf (0.85-1.32) were determined for 6 MV and 24 MV beams at 45° incidence. © 2012 American Association of Physicists in Medicine.

  2. High energy semiconductor switch

    Science.gov (United States)

    Risberg, R. L.

    1989-02-01

    The objective was a controller for electric motors. By operating standard Nema B induction motors at variable speed a great deal of energy is saved. This is especially true in pumping and air conditioning applications. To allow wider use of variable speed AC drives, and to provide improved performance, a better semiconductor switch was sought. This was termed the High Energy Semiconductor Switch.

  3. Experimental high energy physics

    CERN Document Server

    De Paula, L

    2004-01-01

    A summary of the contributions on experimental high energy physics to the XXIV Brazilian National Meeting on Particle and Fields is presented. There were 5 invited talks and 32 submitted contributions. The active Brazilian groups are involved in several interesting projects but suffer from the lack of funding and interaction with Brazilian theorists.

  4. High Energy Exoplanet Transits

    Science.gov (United States)

    Llama, Joe; Shkolnik, Evgenya L.

    2017-10-01

    X-ray and ultraviolet transits of exoplanets allow us to probe the atmospheres of these worlds. High energy transits have been shown to be deeper but also more variable than in the optical. By simulating exoplanet transits using high-energy observations of the Sun, we can test the limits of our ability to accurately measure the properties of these planets in the presence of stellar activity. We use both disk-resolved images of the Solar disk spanning soft X-rays, the ultraviolet, and the optical and also disk-integrated Sun-as-a-star observations of the Lyα irradiance to simulate transits over a wide wavelength range. We find that for stars with activity levels similar to the Sun, the planet-to-star radius ratio can be overestimated by up to 50% if the planet occults an active region at high energies. We also compare our simulations to high energy transits of WASP-12b, HD 189733, 55 Cnc b, and GJ 436b.

  5. High energy battery. Hochenergiebatterie

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, H.; Beyermann, G.; Bulling, M.

    1992-03-26

    In a high energy battery with a large number of individual cells in a housing with a cooling medium flowing through it, it is proposed that the cooling medium should be guided so that it only affects one or both sides of the cells thermally.

  6. High Energy Gamma-rays from FR I Jets

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, Marek

    2003-07-22

    Thanks to Hubble and Chandra telescopes, some of the large scale jets in extragalactic radio sources are now being observed at optical and X-ray frequencies. For the FR I objects the synchrotron nature of this emission is surely established, although a lot of uncertainties--connected for example with the particle acceleration processes involved--remain. In this paper we study production of high energy {gamma}-rays in FR I kiloparsec-scale jets by inverse-Compton emission of the synchrotron-emitting electrons. We consider different origin of seed photons contributing to the inverse-Compton scattering, including nuclear jet radiation as well as ambient, stellar and circumstellar emission of the host galaxies. We discuss how future detections or non-detections of the evaluated {gamma}-ray fluxes can provide constraints on the unknown large scale jet parameters, i.e. the magnetic field intensity and the jet Doppler factor. For the nearby sources Centaurus A and M 87, we find measurable fluxes of TeV photons resulting from synchrotron self-Compton process and from comptonization of the galactic photon fields, respectively. In the case of Centaurus A, we also find a relatively strong emission component due to comptonization of the nuclear blazar photons, which could be easily observed by GLAST at energy {approx} 10 GeV, providing important test for the unification of FR I sources with BL Lac objects.

  7. Effect of silicone gel breast prosthesis on electron and photon dose distributions

    Energy Technology Data Exchange (ETDEWEB)

    Krishnan, L.; St. George, F.J.; Mansfield, C.M.; Krishnan, E.C.

    1983-01-01

    The effect of a silicone gel breast prosthesis on the absorbed dose distribution of 9--20 MeV electron beams and 1.25--15 MV photon beams was studied. Compared to water measurements, at depths smaller than the practical range of the electron beams, the central axis depth dose values below the prothesis were lower for all energies by as much as 3.5%. However, at depths near the practical range, the central axis depth dose values for the prosthesis were greater than that of water by as much as 33%. Since this occurs near the end of the electron range, the resultant difference may not be clinically significant. Results of the effect of breast prosthesis on photon depth dose distributions reveal that no clinically significant perturbation is produced by the breast prosthesis using Co-60, 6- and 15-MV radiations.

  8. Time-dependent density functional theory for many-electron systems interacting with cavity photons.

    Science.gov (United States)

    Tokatly, I V

    2013-06-07

    Time-dependent (current) density functional theory for many-electron systems strongly coupled to quantized electromagnetic modes of a microcavity is proposed. It is shown that the electron-photon wave function is a unique functional of the electronic (current) density and the expectation values of photonic coordinates. The Kohn-Sham system is constructed, which allows us to calculate the above basic variables by solving self-consistent equations for noninteracting particles. We suggest possible approximations for the exchange-correlation potentials and discuss implications of this approach for the theory of open quantum systems. In particular we show that it naturally leads to time-dependent density functional theory for systems coupled to the Caldeira-Leggett bath.

  9. Predicting Induced Radioactivity at High Energy Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Fasso, Alberto

    1999-08-27

    Radioactive nuclides are produced at high-energy electron accelerators by different kinds of particle interactions with accelerator components and shielding structures. Radioactivity can also be induced in air, cooling fluids, soil and groundwater. The physical reactions involved include spallations due to the hadronic component of electromagnetic showers, photonuclear reactions by intermediate energy photons and low-energy neutron capture. Although the amount of induced radioactivity is less important than that of proton accelerators by about two orders of magnitude, reliable methods to predict induced radioactivity distributions are essential in order to assess the environmental impact of a facility and to plan its decommissioning. Conventional techniques used so far are reviewed, and a new integrated approach is presented, based on an extension of methods used at proton accelerators and on the unique capability of the FLUKA Monte Carlo code to handle the whole joint electromagnetic and hadronic cascade, scoring residual nuclei produced by all relevant particles. The radiation aspects related to the operation of superconducting RF cavities are also addressed.

  10. Electron- and photon-impact ionization of furfural

    Energy Technology Data Exchange (ETDEWEB)

    Jones, D. B. [School of Chemical and Physical Sciences, Flinders University, GPO Box 2100, Adelaide, SA 5001 (Australia); Ali, E.; Madison, D. H., E-mail: plimaovieira@fct.unl.pt, E-mail: madison@mst.edu, E-mail: michael.brunger@flinders.edu.au [Department of Physics, Missouri University of Science and Technology, Rolla, Missouri 65409 (United States); Nixon, K. L. [Departamento de Física, Universidade Federal de Juiz de Fora, Juiz de Fora, MG (Brazil); School of Biology, Chemistry and Forensic Science, University of Wolverhampton, Wolverhampton WV1 1LY (United Kingdom); Limão-Vieira, P., E-mail: plimaovieira@fct.unl.pt, E-mail: madison@mst.edu, E-mail: michael.brunger@flinders.edu.au [Laboratório de Colisões Atómicas e Moleculares, CEFITEC, Departamento de Física, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Hubin-Franskin, M.-J.; Delwiche, J. [Départment de Chimie, Université de Liège, Institut de Chimie-Bât. B6C, B-4000 Liège 1 (Belgium); Ning, C. G. [State Key Laboratory of Low-Dimensional Quantum Physics, Department of Physics, Tsinghua University, Beijing 100084 (China); Colgan, J. [Theoretical Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Murray, A. J. [Photon Science Institute, School of Physics and Astronomy, University of Manchester, Manchester M13 9PL (United Kingdom); and others

    2015-11-14

    The He(I) photoelectron spectrum of furfural has been investigated, with its vibrational structure assigned for the first time. The ground and excited ionized states are assigned through ab initio calculations performed at the outer-valence Green’s function level. Triple differential cross sections (TDCSs) for electron-impact ionization of the unresolved combination of the 4a″  +  21a′ highest and next-highest occupied molecular orbitals have also been obtained. Experimental TDCSs are recorded in a combination of asymmetric coplanar and doubly symmetric coplanar kinematics. The experimental TDCSs are compared to theoretical calculations, obtained within a molecular 3-body distorted wave framework that employed either an orientation average or proper TDCS average. The proper average calculations suggest that they may resolve some of the discrepancies regarding the angular distributions of the TDCS, when compared to calculations employing the orbital average.

  11. Theory of quantum-circuit refrigeration by photon-assisted electron tunneling

    Science.gov (United States)

    Silveri, Matti; Grabert, Hermann; Masuda, Shumpei; Tan, Kuan Yen; Möttönen, Mikko

    2017-09-01

    We focus on a recently experimentally realized scenario of normal-metal-insulator-superconductor tunnel junctions coupled to a superconducting resonator. We develop a first-principles theory to describe the effect of photon-assisted electron tunneling on the quantum state of the resonator. Our results are in very good quantitative agreement with the previous experiments on refrigeration and heating of the resonator using the photon-assisted tunneling, thus providing a stringent verification of the developed theory. Importantly, our results provide simple analytical estimates of the voltage-tunable coupling strength and temperature of the thermal reservoir formed by the photon-assisted tunneling. Consequently, they are used to introduce optimization principles for initialization of quantum devices using such a quantum-circuit refrigerator. Thanks to the first-principles nature of our approach, extension of the theory to the full spectrum of quantum electric devices seems plausible.

  12. Monte Carlo simulations and benchmark measurements on the response of TE(TE) and Mg(Ar) ionization chambers in photon, electron and neutron beams

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yi-Chun [Health Physics Division, Institute of Nuclear Energy Research, Taoyuan County, Taiwan (China); Huang, Tseng-Te, E-mail: huangtt@iner.gov.tw [Health Physics Division, Institute of Nuclear Energy Research, Taoyuan County, Taiwan (China); Liu, Yuan-Hao [Nuclear Science and Technology Development Center, National Tsing Hua University, Hsinchu City, Taiwan (China); Chen, Wei-Lin [Institute of Nuclear Engineering and Science, National Tsing Hua University, Hsinchu City, Taiwan (China); Chen, Yen-Fu [Atomic Energy Council, New Taipei City, Taiwan (China); Wu, Shu-Wei [Dept. of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan (China); Nievaart, Sander [Institute for Energy, Joint Research Centre, European Commission, Petten (Netherlands); Jiang, Shiang-Huei [Dept. of Engineering and System Science, National Tsing Hua University, Hsinchu, Taiwan (China)

    2015-06-01

    The paired ionization chambers (ICs) technique is commonly employed to determine neutron and photon doses in radiology or radiotherapy neutron beams, where neutron dose shows very strong dependence on the accuracy of accompanying high energy photon dose. During the dose derivation, it is an important issue to evaluate the photon and electron response functions of two commercially available ionization chambers, denoted as TE(TE) and Mg(Ar), used in our reactor based epithermal neutron beam. Nowadays, most perturbation corrections for accurate dose determination and many treatment planning systems are based on the Monte Carlo technique. We used general purposed Monte Carlo codes, MCNP5, EGSnrc, FLUKA or GEANT4 for benchmark verifications among them and carefully measured values for a precise estimation of chamber current from absorbed dose rate of cavity gas. Also, energy dependent response functions of two chambers were calculated in a parallel beam with mono-energies from 20 keV to 20 MeV photons and electrons by using the optimal simple spherical and detailed IC models. The measurements were performed in the well-defined (a) four primary M-80, M-100, M120 and M150 X-ray calibration fields, (b) primary {sup 60}Co calibration beam, (c) 6 MV and 10 MV photon, (d) 6 MeV and 18 MeV electron LINACs in hospital and (e) BNCT clinical trials neutron beam. For the TE(TE) chamber, all codes were almost identical over the whole photon energy range. In the Mg(Ar) chamber, MCNP5 showed lower response than other codes for photon energy region below 0.1 MeV and presented similar response above 0.2 MeV (agreed within 5% in the simple spherical model). With the increase of electron energy, the response difference between MCNP5 and other codes became larger in both chambers. Compared with the measured currents, MCNP5 had the difference from the measurement data within 5% for the {sup 60}Co, 6 MV, 10 MV, 6 MeV and 18 MeV LINACs beams. But for the Mg(Ar) chamber, the derivations

  13. Ion energy distributions from photon- and electron-stimulated desorption. II. The quasiclassical final state and reneutralization

    Science.gov (United States)

    Clinton, William L.; Pal, Sipra; Jutila, Ronald E.

    1987-09-01

    Franck-Condon overlap integrals are calculated to fit ion energy distributions (IED's) resulting from photon- or electron-stimulated desorption. The WKB or quasiclassical trajectory approximation is used to compute the final-state wave function. The final-state potential consists of a repulsive exponential and an image term. The calculated IED's compare well with those found previously using the reflection or classical trajectory approximation. Both methods agree well with a wide range of experimental IED's all of which are mildly asymmetric Gaussian functions of the ion energy. It is shown how these two approximations are related through the classical limit of the final-state wave function. In addition, the quasiclassical wave function is generalized to include an optical potential giving rise in a natural way to the reneutralization reduction factor. The Gaussian asymmetry in the IED's is usually to the high-energy side reflecting a ``normal'' exponential repulsion. However, in a few anomalous cases the Gaussian is skewed to the low-energy side of the IED peak. This anomaly cannot be explained by expected influences on the initial-state wave function such as anharmonicities. On the other hand, the reneutralization factor, when it predominates, provides a natural explanation for this effect. In addition, this reneutralization factor can cause significant shifts in the IED peak, away from the Franck-Condon peak.

  14. A radiation belt monitor for the High Energy Transient Experiment Satellite

    Science.gov (United States)

    Lo, D. H.; Wenzel, K. W.; Petrasso, R. D.; Prigozhin, G. Y.; Doty, J.; Ricker, G.

    1993-01-01

    A Radiation Belt Monitor (RBM) sensitive to protons and electrons with energy approximately greater than 0.5 MeV has been designed for the High Energy Transient Experiment (HETE) satellite in order to: first, control the on-off configuration of the experiments (i.e. those susceptible to proton damage); and second, to indicate the presence of proton and/or electron events that could masquerade as legitimate high energy photon events. One of the two RBM channels has an enhanced sensitivity to electrons. Each channel of the RBM, based on a PIN silicon diode, requires a typical power of 6 milliwatts. Tests have been performed with protons with energies from approximately 0.1 to 2.5 MeV (generated by a Cockcroft-Walton linear accelerator via the d(d,p)t reaction), and with electrons with energies up to 1 MeV (from a 1.0 microcurie Bi-207 source).

  15. Adaptation of penelope Monte Carlo code system to the absorbed dose metrology: characterization of high energy photon beams and calculations of reference dosimeter correction factors; Adaptation du code Monte Carlo penelope pour la metrologie de la dose absorbee: caracterisation des faisceaux de photons X de haute energie et calcul de facteurs de correction de dosimetres de reference

    Energy Technology Data Exchange (ETDEWEB)

    Mazurier, J

    1999-05-28

    This thesis has been performed in the framework of national reference setting-up for absorbed dose in water and high energy photon beam provided with the SATURNE-43 medical accelerator of the BNM-LPRI (acronym for National Bureau of Metrology and Primary standard laboratory of ionising radiation). The aim of this work has been to develop and validate different user codes, based on PENELOPE Monte Carlo code system, to determine the photon beam characteristics and calculate the correction factors of reference dosimeters such as Fricke dosimeters and graphite calorimeter. In the first step, the developed user codes have permitted the influence study of different components constituting the irradiation head. Variance reduction techniques have been used to reduce the calculation time. The phase space has been calculated for 6, 12 and 25 MV at the output surface level of the accelerator head, then used for calculating energy spectra and dose distributions in the reference water phantom. Results obtained have been compared with experimental measurements. The second step has been devoted to develop an user code allowing calculation correction factors associated with both BNM-LPRI's graphite and Fricke dosimeters thanks to a correlated sampling method starting with energy spectra obtained in the first step. Then the calculated correction factors have been compared with experimental and calculated results obtained with the Monte Carlo EGS4 code system. The good agreement, between experimental and calculated results, leads to validate simulations performed with the PENELOPE code system. (author)

  16. Photon-Electron Interactions in Dirac Quantum Materials

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xiaodong [Univ. of Washington, Seattle, WA (United States). Dept. of Material Science and Engineering

    2017-11-10

    The objective of this proposal was to explore the fundamental light-matter interactions in a new class of Dirac quantum materials, atomically thin transition metal dichalcogenides (TMDs). Monolayer TMDs are newly discovered two-dimensional semiconductors with direct bandgap. Due to their hexagonal lattice structure, the band edge localizes at corner of Brillouin zone, i.e. “Dirac valleys”. This gives the corresponding electron states a “valley index” (or pseudospin) in addition to the real spin. Remarkably, the valley pseudospins have circularly polarized optical selection rules, providing the first solid state system for dynamic control of the valley degree of freedom. During this award, we have developed a suite of advanced nano-optical spectroscopy tools in the investigation and manipulation of charge, spin, and valley degrees of freedom in monolayer semiconductors. Emerging physical phenomena, such as quantum coherence between valley pseudospins, have been demonstrated for the first time in solids. In addition to monolayers, we have developed a framework in engineering, formulating, and understanding valley pseudospin physics in 2D heterostructures formed by different monolayer semiconductors. We demonstrated long-lived valley-polarized interlayer excitons with valley-dependent many-body interaction effects. These works push the research frontier in understanding the light-matter interactions in atomically-thin quantum materials for protentional transformative energy technologies.

  17. On the Coupling of Photon Spin to Electron Orbital Angular Momentum

    CERN Document Server

    Fischer, Ulrich C; Fuchs, Harald; Salut, Roland; Lefier, Yannick; Grosjean, Thierry

    2016-01-01

    Partially gold coated 90 degree glass wedges and a semi - infinite slit in a thin film of gold ending in a conducting nano-junction serve as samples to investigate the transfer of photon spin to electron orbital angular momentum. These structures were specifically designed as samples where an incident beam of light is retroreflected. Since in the process of retroreflection the turning sense of a circularly polarized beam of light does not change and the direction of propagation is inverted, the photon spin is inverted. Due to conservation of angular momentum a transfer of photon spin to electron orbital angular momentum of conduction electrons occurs. In the structures a circular movement of electrons is blocked and therefore the transfered spin can be detected as a photovoltage due to an electromotive force which is induced by the transfer of angular momentum. Depending on the polarization of the incident beam, a maximum photovoltage of about 0,2 micro V was measured for both structures. The results are inte...

  18. Effective atomic numbers, electron densities and kinetic energy released in matter of vitamins for photon interaction

    Science.gov (United States)

    Shantappa, A.; Hanagodimath, S. M.

    2014-01-01

    Effective atomic numbers, electron densities of some vitamins (Retinol, Riboflavin, Niacin, Biotin, Folic acid, Cobalamin, Phylloquinone and Flavonoids) composed of C, H, O, N, Co, P and S have been calculated for total and partial photon interactions by the direct method for energy range 1 keV-100 GeV by using WinXCOM and kinetic energy released in matter (Kerma) relative to air is calculated in energy range of 1 keV-20 MeV. Change in effective atomic number and electron density with energy is calculated for all photon interactions. Variation of photon mass attenuation coefficients with energy are shown graphically only for total photon interaction. It is observed that change in mass attenuation coefficient with composition of different chemicals is very large below 100 keV and moderate between 100 keV and 10 MeV and negligible above 10 MeV. Behaviour of vitamins is almost indistinguishable except biotin and cobalamin because of large range of atomic numbers from 1(H) to 16 (S) and 1(H) to 27(Co) respectively. K a value shows a peak due to the photoelectric effect around K-absorption edge of high- Z constituent of compound for biotin and cobalamin.

  19. Very High Energy Neutrinos from nearby long GRB Afterglows

    Science.gov (United States)

    Thomas, Jessymol K.; Moharana, Reetanjali; Razzaque, Soebur

    2017-09-01

    Long duration Gamma Ray Bursts (GRBs) are well-motivated sources of Ultra High Energy Cosmic Rays (UHECRs) and neutrinos. During the afterglow phase these particles can be produced as a result of acceleration and interaction there in. We have modeled afterglow spectra and light curves from synchrotron cooling of accelerated electrons. We have fitted data of 17 long GRBs detected within redshift 0.5 in case of the GRB blastwave evolving in a wind and constant density interstellar medium. The afterglow photons can interact with the shock accelerated protons to produce very high energy neutrinos. We have calculated the neutrino flux for photo-pion interactions for all these GRBs. As IceCube have been detecting very high energy neutrinos for the last four years and a larger future extension called Gen 2 is planned, this calculation will help in understanding more about GRB neutrino production. Calculation of flux and estimation of events for Northern Hemisphere GRBs are done for the upcoming neutrino observatory KM3NeT.

  20. The Photon-Assisted Cascaded Electron Multiplier: a concept for potential avalanche-ion blocking

    Science.gov (United States)

    Veloso, J. F. C. A.; Amaro, F. D.; dos Santos, J. M. F.; Breskin, A.; Lyashenko, A.; Chechik, R.

    2006-08-01

    We present a Photon-Assisted Cascaded Electron Multipliers (PACEM) which has a potential for ion back-flow blocking in gaseous radiation detectors: the avalanche from a first multiplication stage propagates to the successive one via its photons, which in turn induce photoelectron emission from a photocathode deposited on the second multiplier stage; the multiplication process may further continue via electron-avalanche propagation. The photonmediated stage allows, by a proper choice of geometry and fields, complete blocking of the ion back-flow into the first element; thus, only ions from the latter will flow back to the drift region. The PACEM concept was validated in a double-MHSP (Micro-Hole & Strip Plate) cascaded multiplier operated in xenon, where the intermediate scintillation stage provided optical gain of ~60. The double-MHSP detector had a total gain above 104 and energy resolution of 18% FWHM for 5.9 keV x-rays.

  1. The Photon-Assisted Cascaded Electron Multiplier: a concept for potential avalanche-ion blocking

    Energy Technology Data Exchange (ETDEWEB)

    Veloso, J F C A [Physics Dept., University of Aveiro, 3810-193 Aveiro (Portugal); Amaro, F D [Physics Dept., University of Coimbra, 3004-516 Coimbra (Portugal); Santos, J M F dos [Physics Dept., University of Coimbra, 3004-516 Coimbra (Portugal); Breskin, A [Dept. of Particle Physics, Weizmann Institute of Science, 76100 Rehovot (Israel); Lyashenko, A [Dept. of Particle Physics, Weizmann Institute of Science, 76100 Rehovot (Israel); Chechik, R [Dept. of Particle Physics, The Weizmann Institute of Science, 76100 Rehovot (Israel)

    2006-08-15

    We present a Photon-Assisted Cascaded Electron Multipliers (PACEM) which has a potential for ion back-flow blocking in gaseous radiation detectors: the avalanche from a first multiplication stage propagates to the successive one via its photons, which in turn induce photoelectron emission from a photocathode deposited on the second multiplier stage; the multiplication process may further continue via electron-avalanche propagation. The photonmediated stage allows, by a proper choice of geometry and fields, complete blocking of the ion back-flow into the first element; thus, only ions from the latter will flow back to the drift region. The PACEM concept was validated in a double-MHSP (Micro-Hole and Strip Plate) cascaded multiplier operated in xenon, where the intermediate scintillation stage provided optical gain of {approx}60. The double-MHSP detector had a total gain above 10{sup 4} and energy resolution of 18% FWHM for 5.9 keV x-rays.

  2. Electronic simulation of the temporal characteristics of photon memory echoes and some related applications

    Science.gov (United States)

    Kuo, Yuwen; Chatterjee, Monish R.

    1994-01-01

    The characteristics of nonlinear photon memory echoes are investigated by means of SPICE simulations using equivalent resonator ensembles. By developing implicit nonlinear circuit models in the memory echo domain, the triple product formalism of electronic holography, involving correlation and convolution, is tested for the storage and recall of arbitrary signals and/or data bit streams in both time-inverted and nontime-inverted modes. Furthermore, a few specific optical data processing applications are also simulated in which the mixed binary multiplication of two or more binary bit streams is achieved. Higher order products, optical pattern recognition, and other possible applications are also discussed. It is shown that much insight into the nature and scope of optical photon echoes as memory storage phenomena may be derived using the electronic simulation technique.

  3. Pulse shapes from electron and photon induced events in segmented high-purity germanium detectors

    CERN Document Server

    Abt, I; Kröninger, K; Liu, J; Liu, X; Majorovits, B

    2007-01-01

    Experiments built to search for neutrinoless double beta-decay are limited in their sensitivity not only by the exposure but also by the amount of background encountered. Radioactive isotopes in the surrounding of the detectors which emit gamma-radiation are expected to be a significant source of background in the GERmanium Detector Array, GERDA. Methods to select electron induced events and discriminate against photon induced events inside a germanium detector are presented in this paper. The methods are based on the analysis of the time structure of the detector response. Data were taken with a segmented GERDA prototype detector. It is shown that the analysis of the time response of the detector can be used to distinguish multiply scattered photons from electrons.

  4. Handbook of theoretical atomic physics data for photon absorption, electron scattering, and vacancies decay

    CERN Document Server

    Amusia, Miron Ya; Yarzhemsky, Victor

    2012-01-01

    The aim of this book is to present highly accurate and extensive theoretical Atomic data and to give a survey of selected calculational methods for atomic physics, used to obtain these data. The book presents the results of calculations of cross sections and probabilities of a broad variety of atomic processes with participation of photons and electrons, namely on photoabsorption, electron scattering and accompanying effects. Included are data for photoabsorption and electron scattering cross-sections and probabilities of vacancy decay formed for a large number of atoms and ions. Attention is also given to photoionization and vacancy decay in endohedrals and to positron-atom scattering. The book is richly illustrated. The methods used are one-electron Hartree-Fock and the technique of Feynman diagrams that permits to include many-electron correlations. This is done in the frames of the Random Phase approximation with exchange and the many-body perturbation theory. Newly obtained and previously collected atomi...

  5. Theoretical High Energy Physics

    Energy Technology Data Exchange (ETDEWEB)

    Christ, Norman H.; Weinberg, Erick J.

    2014-07-14

    we provide reports from each of the six faculty supported by the Department of Energy High Energy Physics Theory grant at Columbia University. Each is followed by a bibliography of the references cited. A complete list of all of the publications in the 12/1/2010-04/30/2014 period resulting from research supported by this grant is provided in the following section. The final section lists the Ph.D. dissertations based on research supported by the grant that were submitted during this period.

  6. High energy cosmic rays

    CERN Document Server

    Stanev, Todor

    2010-01-01

    Offers an accessible text and reference (a cosmic-ray manual) for graduate students entering the field and high-energy astrophysicists will find this an accessible cosmic-ray manual Easy to read for the general astronomer, the first part describes the standard model of cosmic rays based on our understanding of modern particle physics. Presents the acceleration scenario in some detail in supernovae explosions as well as in the passage of cosmic rays through the Galaxy. Compares experimental data in the atmosphere as well as underground are compared with theoretical models

  7. Fast Monte Carlo Electron-Photon Transport Method and Application in Accurate Radiotherapy

    Science.gov (United States)

    Hao, Lijuan; Sun, Guangyao; Zheng, Huaqing; Song, Jing; Chen, Zhenping; Li, Gui

    2014-06-01

    Monte Carlo (MC) method is the most accurate computational method for dose calculation, but its wide application on clinical accurate radiotherapy is hindered due to its poor speed of converging and long computation time. In the MC dose calculation research, the main task is to speed up computation while high precision is maintained. The purpose of this paper is to enhance the calculation speed of MC method for electron-photon transport with high precision and ultimately to reduce the accurate radiotherapy dose calculation time based on normal computer to the level of several hours, which meets the requirement of clinical dose verification. Based on the existing Super Monte Carlo Simulation Program (SuperMC), developed by FDS Team, a fast MC method for electron-photon coupled transport was presented with focus on two aspects: firstly, through simplifying and optimizing the physical model of the electron-photon transport, the calculation speed was increased with slightly reduction of calculation accuracy; secondly, using a variety of MC calculation acceleration methods, for example, taking use of obtained information in previous calculations to avoid repeat simulation of particles with identical history; applying proper variance reduction techniques to accelerate MC method convergence rate, etc. The fast MC method was tested by a lot of simple physical models and clinical cases included nasopharyngeal carcinoma, peripheral lung tumor, cervical carcinoma, etc. The result shows that the fast MC method for electron-photon transport was fast enough to meet the requirement of clinical accurate radiotherapy dose verification. Later, the method will be applied to the Accurate/Advanced Radiation Therapy System ARTS as a MC dose verification module.

  8. Automated Monte Carlo biasing for photon-generated electrons near surfaces.

    Energy Technology Data Exchange (ETDEWEB)

    Franke, Brian Claude; Crawford, Martin James; Kensek, Ronald Patrick

    2009-09-01

    This report describes efforts to automate the biasing of coupled electron-photon Monte Carlo particle transport calculations. The approach was based on weight-windows biasing. Weight-window settings were determined using adjoint-flux Monte Carlo calculations. A variety of algorithms were investigated for adaptivity of the Monte Carlo tallies. Tree data structures were used to investigate spatial partitioning. Functional-expansion tallies were used to investigate higher-order spatial representations.

  9. Recent progress in organic electronics and photonics: A perspective on the future of organic devices

    KAUST Repository

    Bredas, Jean-Luc

    2016-02-25

    The fields of organic electronics and photonics have witnessed remarkable advances over the past few years. This progress bodes well for the increased utilization of organic materials as the active layers in devices for applications as diverse as light-emitting diodes, field-effect transistors, solar cells, or all-optical switches. In the present document, we choose to focus the discussion on organic all-optical switching applications. © 2015 The Japan Society of Applied Physics.

  10. Elementary particle physics and high energy phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Barker, A.R.; Cumalat, J.P.; de Alwis, S.P.; DeGrand, T.A.; Ford, W.T.; Mahanthappa, K.T.; Nauenberg, U.; Rankin, P.; Smith, J.G.

    1992-06-01

    This report discusses the following research in high energy physics: the properties of the z neutral boson with the SLD detector; the research and development program for the SDC muon detector; the fixed-target k-decay experiments; the Rocky Mountain Consortium for HEP; high energy photoproduction of states containing heavy quarks; and electron-positron physics with the CLEO II and Mark II detectors. (LSP).

  11. Production of high-energy particles in laser and Coulomb fields and the e+e- antenna.

    Science.gov (United States)

    Kuchiev, M Yu

    2007-09-28

    A strong laser field and the Coulomb field of a nucleus can produce e(+) e(-) pairs. It is shown for the first time that there is a large probability that electrons and positrons created in this process collide after one or several oscillations of the laser field. These collisions can take place at high energy, resulting in several phenomena. The quasielastic collision e(+) e(-) --> e(+) e(-) allows acceleration of leptons in the laser field to higher energies. The inelastic collisions allow production of high-energy photons e(+) e(-) --> 2 gamma and muons e(+) e(-) --> micro(+) micro(-). The yield of high-energy photons and muons produced via this mechanism exceeds exponentially their production through conventional direct creation in laser and Coulomb fields. A relation of the phenomena considered with the antenna mechanism of multiphoton absorption in atoms is discussed.

  12. An empirical method for deriving RBE values associated with electrons, photons and radionuclides.

    Science.gov (United States)

    Bellamy, M; Puskin, J; Hertel, N; Eckerman, K

    2015-12-01

    There is substantial evidence to justify using relative biological effectiveness (RBE) values of >1 for low-energy electrons and photons. But, in the field of radiation protection, radiation associated with low linear energy transfer has been assigned a radiation weighting factor wR of 1. This value may be suitable for radiation protection but, for risk considerations, it is important to evaluate the potential elevated biological effectiveness of radiation to improve the quality of risk estimates. RBE values between 2 and 3 for tritium are implied by several experimental measurements. Additionally, elevated RBE values have been found for other similar low-energy radiation sources. In this work, RBE values are derived for electrons based upon the fractional deposition of absorbed dose of energies less than a few kiloelectron volts. Using this empirical method, RBE values were also derived for monoenergetic photons and 1070 radionuclides from ICRP Publication 107 for which photons and electrons are the primary emissions. Published by Oxford University Press 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  13. Overview of Energy Reconstruction, and Electron and Photon Performances with the CMS ECAL in Run II

    Science.gov (United States)

    Teixeira de Lima, Rafael; CMS Collaboration

    2017-11-01

    The electromagnetic calorimeter (ECAL) of the Compact Muon Solenoid (CMS) Experiment is crucial for achieving high resolution measurements of electrons and photons. Maintaining and possibly improving the excellent performance achieved in Run I is vital for measurements of the Standard Model Higgs boson and searches for new higher mass resonances in final states with electrons and photons. Since spring 2015, the ECAL has operated with proton-proton collisions at 13 TeV center-of-mass energy and at a reduced bunch spacing of 25 ns. The instantaneous luminosity delivered by the LHC during Run II is expected to exceed the levels previously attained. The average number of concurrent proton-proton collisions per bunch-crossing (pileup) is expected to reach up to 40 interactions. In this summary we present new crystal energy reconstruction algorithms and clustering techniques that have been developed to maintain the excellent performance of the CMS ECAL throughout Run II. We will show first performance results from 2015 data, achieved through energy calibrations using electrons from W and Z boson decays, photons from π 0/η decays, and the azimuthally symmetric energy distribution of minimum bias events. Lastly, we present an outlook on the expected Run II performance in the next years.

  14. Group IV Light Sources to Enable the Convergence of Photonics and Electronics

    Directory of Open Access Journals (Sweden)

    Shinichi eSaito

    2014-09-01

    Full Text Available Group IV lasers are expected to revolutionize chip-to-chip optical communications in terms of cost, scalability, yield, and compatibility to the existing infrastructure of silicon industries for mass production. Here, we review the current state-of-the-art developments of silicon and germanium light sources towards monolithic integration. Quantum confinement of electrons and holes in nano-structures has been the primary route for light emission from silicon, and we can use advanced silicon technologies using top-down patterning processes to fabricate these nano-structures, including fin-type vertical multiple quantum wells. Moreover, the electromagnetic environment can also be manipulated in a photonic crystal nano-cavity to enhance the efficiency of light extraction and emission by the Purcell effect. Germanium is also widely investigated as an active material in Group IV photonics, and novel epitaxial growth technologies are being developed to make a high quality germanium layer on a silicon substrate. To develop a practical germanium laser, various technologies are employed for tensile-stress engineering and high electron doping to compensate the indirect valleys in the conduction band. These challenges are aiming to contribute towards the convergence of electronics and photonics on a silicon chip.

  15. Group IV Light Sources to Enable the Convergence of Photonics and Electronics

    Science.gov (United States)

    Saito, Shinichi; Gardes, Frederic; Al-Attili, Abdelrahman; Tani, Kazuki; Oda, Katsuya; Suwa, Yuji; Ido, Tatemi; Ishikawa, Yasuhiko; Kako, Satoshi; Iwamoto, Satoshi; Arakawa, Yasuhiko

    2014-09-01

    Group IV lasers are expected to revolutionize chip-to-chip optical communications in terms of cost, scalability, yield, and compatibility to the existing infrastructure of silicon industries for mass production. Here, we review the current state-of-the-art developments of silicon and germanium light sources towards monolithic integration. Quantum confinement of electrons and holes in nano-structures has been the primary route for light emission from silicon, and we can use advanced silicon technologies using top-down patterning processes to fabricate these nano-structures, including fin-type vertical multiple quantum wells. Moreover, the electromagnetic environment can also be manipulated in a photonic crystal nano-cavity to enhance the efficiency of light extraction and emission by the Purcell effect. Germanium is also widely investigated as an active material in Group IV photonics, and novel epitaxial growth technologies are being developed to make a high quality germanium layer on a silicon substrate. To develop a practical germanium laser, various technologies are employed for tensile-stress engineering and high electron doping to compensate the indirect valleys in the conduction band. These challenges are aiming to contribute towards the convergence of electronics and photonics on a silicon chip.

  16. Monte Carlo based beam model using a photon MLC for modulated electron radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Henzen, D., E-mail: henzen@ams.unibe.ch; Manser, P.; Frei, D.; Volken, W.; Born, E. J.; Vetterli, D.; Chatelain, C.; Fix, M. K. [Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, CH-3010 Berne (Switzerland); Neuenschwander, H. [Clinic for Radiation-Oncology, Lindenhofspital Bern, CH-3012 Berne (Switzerland); Stampanoni, M. F. M. [Institute for Biomedical Engineering, ETH Zürich and Paul Scherrer Institut, CH-5234 Villigen (Switzerland)

    2014-02-15

    Purpose: Modulated electron radiotherapy (MERT) promises sparing of organs at risk for certain tumor sites. Any implementation of MERT treatment planning requires an accurate beam model. The aim of this work is the development of a beam model which reconstructs electron fields shaped using the Millennium photon multileaf collimator (MLC) (Varian Medical Systems, Inc., Palo Alto, CA) for a Varian linear accelerator (linac). Methods: This beam model is divided into an analytical part (two photon and two electron sources) and a Monte Carlo (MC) transport through the MLC. For dose calculation purposes the beam model has been coupled with a macro MC dose calculation algorithm. The commissioning process requires a set of measurements and precalculated MC input. The beam model has been commissioned at a source to surface distance of 70 cm for a Clinac 23EX (Varian Medical Systems, Inc., Palo Alto, CA) and a TrueBeam linac (Varian Medical Systems, Inc., Palo Alto, CA). For validation purposes, measured and calculated depth dose curves and dose profiles are compared for four different MLC shaped electron fields and all available energies. Furthermore, a measured two-dimensional dose distribution for patched segments consisting of three 18 MeV segments, three 12 MeV segments, and a 9 MeV segment is compared with corresponding dose calculations. Finally, measured and calculated two-dimensional dose distributions are compared for a circular segment encompassed with a C-shaped segment. Results: For 15 × 34, 5 × 5, and 2 × 2 cm{sup 2} fields differences between water phantom measurements and calculations using the beam model coupled with the macro MC dose calculation algorithm are generally within 2% of the maximal dose value or 2 mm distance to agreement (DTA) for all electron beam energies. For a more complex MLC pattern, differences between measurements and calculations are generally within 3% of the maximal dose value or 3 mm DTA for all electron beam energies. For the

  17. Unfolding linac photon spectra and incident electron energies from experimental transmission data, with direct independent validation.

    Science.gov (United States)

    Ali, E S M; McEwen, M R; Rogers, D W O

    2012-11-01

    In a recent computational study, an improved physics-based approach was proposed for unfolding linac photon spectra and incident electron energies from transmission data. In this approach, energy differentiation is improved by simultaneously using transmission data for multiple attenuators and detectors, and the unfolding robustness is improved by using a four-parameter functional form to describe the photon spectrum. The purpose of the current study is to validate this approach experimentally, and to demonstrate its application on a typical clinical linac. The validation makes use of the recent transmission measurements performed on the Vickers research linac of National Research Council Canada. For this linac, the photon spectra were previously measured using a NaI detector, and the incident electron parameters are independently known. The transmission data are for eight beams in the range 10-30 MV using thick Be, Al and Pb bremsstrahlung targets. To demonstrate the approach on a typical clinical linac, new measurements are performed on an Elekta Precise linac for 6, 10 and 25 MV beams. The different experimental setups are modeled using EGSnrc, with the newly added photonuclear attenuation included. For the validation on the research linac, the 95% confidence bounds of the unfolded spectra fall within the noise of the NaI data. The unfolded spectra agree with the EGSnrc spectra (calculated using independently known electron parameters) with RMS energy fluence deviations of 4.5%. The accuracy of unfolding the incident electron energy is shown to be ∼3%. A transmission cutoff of only 10% is suitable for accurate unfolding, provided that the other components of the proposed approach are implemented. For the demonstration on a clinical linac, the unfolded incident electron energies and their 68% confidence bounds for the 6, 10 and 25 MV beams are 6.1 ± 0.1, 9.3 ± 0.1, and 19.3 ± 0.2 MeV, respectively. The unfolded spectra for the clinical linac agree with the

  18. Photon-Photon Scattering at the Photon Linear Collider

    OpenAIRE

    Jikia, G.; Tkabladze, A.

    1993-01-01

    Photon-photon scattering at the Photon Linear Collider is considered. Explicit formulas for helicity amplitudes due to $W$ boson loops are presented. It is shown that photon-photon scattering should be easily observable at PLC and separation of the $W$ loop contribution (which dominates at high energies) will be possible at $e^+e^-$ c.m. energy of 500~GeV or higher.

  19. An ultrafast NbN hot-electron single-photon detector for electronic applications

    CERN Document Server

    Lipatov, A; Smirnov, K V; Chulkova, G; Korneev, A; Kouminov, P; Goltsman, G N; Zhang, J; Slysz, W; Verevkin, A; Sobolewski, R

    2002-01-01

    We present the latest generation of our superconducting single-photon detector (SPD), which can work from ultraviolet to mid-infrared optical radiation wavelengths. The detector combines a high speed of operation and low jitter with high quantum efficiency (QE) and very low dark count level. The technology enhancement allows us to produce ultrathin (3.5 nm thick) structures that demonstrate QE hundreds of times better, at 1.55 mu m, than previous 10 nm thick SPDs. The best, 10x10 mu m sup 2 , SPDs demonstrate QE up to 5% at 1.55 mu m and up to 11% at 0.86 mu m. The intrinsic detector QE, normalized to the film absorption coefficient, reaches 100% at bias currents above 0.9 I sub c for photons with wavelengths shorter than 1.3 mu m.

  20. Generation of intense X-radiation and high-energy-density matter by laser-accelerated electrons; Erzeugung von intensiver Roentgenstrahlung und Materie hoher Energiedichte durch Laserbeschleunigte Elektronen

    Energy Technology Data Exchange (ETDEWEB)

    Schoenlein, Andreas

    2015-07-01

    Aim of this thesis was to study the processes of the interaction between highly intense short-pulse laser and matter. The focus lied thereby on the generation of intense X-radiation and warm dense matter. The studies performed for this thesis comprehend thereby the influence of laser parameters like energy, pulse length, focus size, and intensity as well as the influence of the target geometry on the interaction and generation of high-energy-density matter. In this thesis for this two selected experiments are presented. First a silver foil was used as target, in order to study the generation of radiation at 21 keV. Both bremsstrahlung and characteristic X-radiation were used in order to characterize the interaction. For the second experiment freely standing titanium wires were used as target. Hereby the focus lied on the characterization of the heated matter.

  1. Internal photon and electron dosimetry of the newborn patient—a hybrid computational phantom study

    Science.gov (United States)

    Wayson, Michael; Lee, Choonsik; Sgouros, George; Treves, S. Ted; Frey, Eric; Bolch, Wesley E.

    2012-03-01

    Estimates of radiation absorbed dose to organs of the nuclear medicine patient are a requirement for administered activity optimization and for stochastic risk assessment. Pediatric patients, and in particular the newborn child, represent that portion of the patient population where such optimization studies are most crucial owing to the enhanced tissue radiosensitivities and longer life expectancies of this patient subpopulation. In cases where whole-body CT imaging is not available, phantom-based calculations of radionuclide S values—absorbed dose to a target tissue per nuclear transformation in a source tissue—are required for dose and risk evaluation. In this study, a comprehensive model of electron and photon dosimetry of the reference newborn child is presented based on a high-resolution hybrid-voxel phantom from the University of Florida (UF) patient model series. Values of photon specific absorbed fraction (SAF) were assembled for both the reference male and female newborn using the radiation transport code MCNPX v2.6. Values of electron SAF were assembled in a unique and time-efficient manner whereby the collisional and radiative components of organ dose--for both self- and cross-dose terms—were computed separately. Dose to the newborn skeletal tissues were assessed via fluence-to-dose response functions reported for the first time in this study. Values of photon and electron SAFs were used to assemble a complete set of S values for some 16 radionuclides commonly associated with molecular imaging of the newborn. These values were then compared to those available in the OLINDA/EXM software. S value ratios for organ self-dose ranged from 0.46 to 1.42, while similar ratios for organ cross-dose varied from a low of 0.04 to a high of 3.49. These large discrepancies are due in large part to the simplistic organ modeling in the stylized newborn model used in the OLINDA/EXM software. A comprehensive model of internal dosimetry is presented in this study for

  2. Towards a fully functional integrated photonic-electronic platform via a single SiGe growth step

    National Research Council Canada - National Science Library

    Littlejohns, Callum G; Dominguez Bucio, Thalia; Nedeljkovic, Milos; Wang, Hong; Mashanovich, Goran Z; Reed, Graham T; Gardes, Frederic Y

    2016-01-01

    Silicon-germanium (Si(1-x)Ge(x)) has become a material of great interest to the photonics and electronics industries due to its numerous interesting properties including higher carrier mobilities than Si, a tuneable lattice constant...

  3. Bacillus cereus as indicator in the sterilization of residual water with high energy electrons; Bacillus cereus como indicador en la desinfeccion de aguas residuales con electrones de alta energia

    Energy Technology Data Exchange (ETDEWEB)

    Mejia Z, E

    2000-07-01

    One of the main causes of water pollution is the presence of microorganisms that provoke infections, moreover of chemical substances. The processes of residual water treatment finally require of the disinfection for its use or final disposition. The radiation technology for the residual water treatment by mean of electron beams is an innovator process because as well as decomposing the chemical substance or to degrade them, also it provokes a disinfection by which this is proposed as alternative for disinfection of residual water, with the purpose in reusing the water treated in the agriculture, recreation and industry among others secondary activities, solving environmental or health problems. The objective of this work is to evaluate the use of Bacillus cereus as biological indicator in the disinfection by radiation, using High Energy Electrons. To fulfil with this objective, the work was developed in three stages, the first one consisted in the acquisition, propagation and conservation of the Bacillus cereus stumps, considering Escherichia coli and Salmonella typhimurium as pathogenic germs present in residual water. Moreover, the inocule standardization and the conditions of the Electron accelerator Type Pelletron. In the second stage it was performed the irradiation of aqueous samples of the microorganisms simulating biological pollution and the application to problem samples of a treatment plant sited in the Lerma River zone of mixed residual water. And in the third stage was performed a regression analysis to the reported survival for each kind of microorganisms. The results obtained show that with the use of Electron beams was reduced 6 logarithmic units de E. coli at 129 Gy, for S. typhimurium it was reduced 8 logarithmic units at 383 Gy and the B. cereus at 511 Gy was reduced 6.8 logarithmic units. Of the problem samples irradiated at 500 Gy, the concentration of the total account diminished from 8.70 x 10{sup 7} UFC/ml to 550 UFC/ml, the presence of B

  4. Clinical application of intensity and energy modulated radiotherapy with photon and electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Xiangkui Mu

    2005-01-01

    In modern, advanced radiotherapy (e.g. intensity modulated photon radiotherapy, IMXT) the delivery time for each fraction becomes prolonged to 10-20 minutes compared with the conventional, commonly 2-5 minutes. The biological effect of this prolongation is not fully known. The large number of beam directions in IMXT commonly leads to a large integral dose in the patient. Electrons would reduce the integral dose but are not suitable for treating deep-seated tumour, due to their limited penetration in tissues. By combining electron and photon beams, the dose distributions may be improved compared with either used alone. One obstacle for using electron beams in clinical routine is that there is no available treatment planning systems that optimise electron beam treatments in a similar way as for IMXT. Protons have an even more pronounced dose fall-off, larger penetration depth and less penumbra widening than electrons and are therefore more suitable for advanced radiotherapy. However, proton facilities optimised for advanced radiotherapy are not commonly available. In some instances electron beams may be an acceptable surrogate. The first part of this study is an experimental in vitro study where the situation in a tumour during fractionated radiotherapy is simulated. The effect of the prolonged fraction time is compared with the predictions by radiobiological models. The second part is a treatment planning study to analyse the mixing of electron and photon beams for at complex target volume in comparison with IMXT. In the next step a research version of an electron beam optimiser was used for the improvement of treatment plans. The aim was to develop a method for translating crude energy and intensity matrices for optimised electrons into a deliverable treatment plan without destroying the dose distribution. In the final part, different methods of treating the spinal canal in medulloblastoma were explored in a treatment planning study that was evaluated with

  5. Space-charge effects in high-energy photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Verna, Adriano, E-mail: adriano.verna@uniroma3.it [Dipartimento di Scienze, Università degli Studi Roma Tre, Via della Vasca Navale 84, I-00146 Roma (Italy); CNISM Unità di Roma Tre, Via della Vasca Navale 84, I-00146 Roma (Italy); Greco, Giorgia [Dipartimento di Scienze, Università degli Studi Roma Tre, Via della Vasca Navale 84, I-00146 Roma (Italy); Lollobrigida, Valerio [Dipartimento di Scienze, Università degli Studi Roma Tre, Via della Vasca Navale 84, I-00146 Roma (Italy); Scuola Dottorale in Matematica e Fisica, Università Roma Tre, Via della Vasca Navale 84, I-00146 Roma (Italy); Offi, Francesco; Stefani, Giovanni [Dipartimento di Scienze, Università degli Studi Roma Tre, Via della Vasca Navale 84, I-00146 Roma (Italy); CNISM Unità di Roma Tre, Via della Vasca Navale 84, I-00146 Roma (Italy)

    2016-05-15

    Highlights: • N-body simulations of interacting photoelectrons in hard X-ray experiments. • Secondary electrons have a pivotal role in determining the energy broadening. • Space charge has negligible effects on the photoelectron momentum distribution. • A simple model provides the characteristic time for energy-broadening mechanism. • The feasibility of time-resolved high-energy experiments with FELs is discussed. - Abstract: Pump-and-probe photoelectron spectroscopy (PES) with femtosecond pulsed sources opens new perspectives in the investigation of the ultrafast dynamics of physical and chemical processes at the surfaces and interfaces of solids. Nevertheless, for very intense photon pulses a large number of photoelectrons are simultaneously emitted and their mutual Coulomb repulsion is sufficiently strong to significantly modify their trajectory and kinetic energy. This phenomenon, referred as space-charge effect, determines a broadening and shift in energy for the typical PES structures and a dramatic loss of energy resolution. In this article we examine the effects of space charge in PES with a particular focus on time-resolved hard X-ray (∼10 keV) experiments. The trajectory of the electrons photoemitted from pure Cu in a hard X-ray PES experiment has been reproduced through N-body simulations and the broadening of the photoemission core-level peaks has been monitored as a function of various parameters (photons per pulse, linear dimension of the photon spot, photon energy). The energy broadening results directly proportional to the number N of electrons emitted per pulse (mainly represented by secondary electrons) and inversely proportional to the linear dimension a of the photon spot on the sample surface, in agreement with the literature data about ultraviolet and soft X-ray experiments. The evolution in time of the energy broadening during the flight of the photoelectrons is also studied. Despite its detrimental consequences on the energy

  6. Passive and electro-optic polymer photonics and InP electronics integration

    Science.gov (United States)

    Zhang, Z.; Katopodis, V.; Groumas, P.; Konczykowska, A.; Dupuy, J.-.; Beretta, A.; Dede, A.; Miller, E.; Choi, J. H.; Harati, P.; Jorge, F.; Nodjiadjim, V.; Dinu, R.; Cangini, G.; Vannucci, A.; Felipe, D.; Maese-Novo, A.; Keil, N.; Bach, H.-.; Schell, Martin; Avramopoulos, H.; Kouloumentas, Ch.

    2015-05-01

    Hybrid photonic integration allows individual components to be developed at their best-suited material platforms without sacrificing the overall performance. In the past few years a polymer-enabled hybrid integration platform has been established, comprising 1) EO polymers for constructing low-complexity and low-cost Mach-Zehnder modulators (MZMs) with extremely high modulation bandwidth; 2) InP components for light sources, detectors, and high-speed electronics including MUX drivers and DEMUX circuits; 3) Ceramic (AIN) RF board that links the electronic signals within the package. On this platform, advanced optoelectronic modules have been demonstrated, including serial 100 Gb/s [1] and 2x100 Gb/s [2] optical transmitters, but also 400 Gb/s optoelectronic interfaces for intra-data center networks [3]. To expand the device functionalities to an unprecedented level and at the same time improve the integration compatibility with diversified active / passive photonic components, we have added a passive polymer-based photonic board (polyboard) as the 4th material system. This passive polyboard allows for low-cost fabrication of single-mode waveguide networks, enables fast and convenient integration of various thin-film elements (TFEs) to control the light polarization, and provides efficient thermo-optic elements (TOEs) for wavelength tuning, light amplitude regulation and light-path switching.

  7. Thermal entanglement between π-electrons in silicene and photons; occurrence of phase transitions

    Energy Technology Data Exchange (ETDEWEB)

    Rastgoo, S., E-mail: rastgooo@gmail.com [Mathematics and Computer Science Department, Sirjan University of Technology, Sirjan 78137 (Iran, Islamic Republic of); Golshan, M.M., E-mail: golshan@susc.ac.ir [Physics Department, College of Sciences, Shiraz University, Shiraz 71454 (Iran, Islamic Republic of)

    2017-03-18

    In this article, the thermal entanglement between π-electronic states in a monolayer silicene sheet and a single mode quantized electromagnetic field is investigated. We assume that the system is in thermal equilibrium with the environment at a temperature T, so that the whole system is described by the Boltzmann distribution. Using the states of total Hamiltonian, the thermal density matrix and, consequently, its partially transposed one is computed, giving rise to the determination of negativity. Our analytical calculations, along with representative figures, show that the system is separable at zero temperature, exhibits a maximum, at a specific temperature, and asymptotically vanishes. Along these lines we also report the effects of electron–photon coupling, as well as the silicene buckling, on the entanglement. Specifically, we demonstrate that the maximal value of entanglement is larger for stronger electron–photon coupling, while it decreases for larger buckling effect. Moreover, we show that the gap in the total energy spectrum remains intact for any value of the buckling parameter. There is, however, one state whose energy changes sign, at a specific buckling, indicating a change of phase. - Highlights: • Thermal entanglement between π-electrons and photons in silicene is reported. • Intrinsic spin-orbit coupling and buckling effect are taken into account. • The ground state of the system is shown to be separable. • Thermal entanglement exhibits a maximum at a certain controllable temperature. • A rapid increase in the negativity for small temperature and buckling indicates a phase transition.

  8. Ant colony algorithm implementation in electron and photon Monte Carlo transport: Application to the commissioning of radiosurgery photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Pareja, S.; Galan, P.; Manzano, F.; Brualla, L.; Lallena, A. M. [Servicio de Radiofisica Hospitalaria, Hospital Regional Universitario ' ' Carlos Haya' ' , Avda. Carlos Haya s/n, E-29010 Malaga (Spain); Unidad de Radiofisica Hospitalaria, Hospital Xanit Internacional, Avda. de los Argonautas s/n, E-29630 Benalmadena (Malaga) (Spain); NCTeam, Strahlenklinik, Universitaetsklinikum Essen, Hufelandstr. 55, D-45122 Essen (Germany); Departamento de Fisica Atomica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada (Spain)

    2010-07-15

    Purpose: In this work, the authors describe an approach which has been developed to drive the application of different variance-reduction techniques to the Monte Carlo simulation of photon and electron transport in clinical accelerators. Methods: The new approach considers the following techniques: Russian roulette, splitting, a modified version of the directional bremsstrahlung splitting, and the azimuthal particle redistribution. Their application is controlled by an ant colony algorithm based on an importance map. Results: The procedure has been applied to radiosurgery beams. Specifically, the authors have calculated depth-dose profiles, off-axis ratios, and output factors, quantities usually considered in the commissioning of these beams. The agreement between Monte Carlo results and the corresponding measurements is within {approx}3%/0.3 mm for the central axis percentage depth dose and the dose profiles. The importance map generated in the calculation can be used to discuss simulation details in the different parts of the geometry in a simple way. The simulation CPU times are comparable to those needed within other approaches common in this field. Conclusions: The new approach is competitive with those previously used in this kind of problems (PSF generation or source models) and has some practical advantages that make it to be a good tool to simulate the radiation transport in problems where the quantities of interest are difficult to obtain because of low statistics.

  9. Dielectric laser acceleration of non-relativistic electrons at a photonic structure

    Energy Technology Data Exchange (ETDEWEB)

    Breuer, John

    2013-08-29

    This thesis reports on the observation of dielectric laser acceleration of non-relativistic electrons via the inverse Smith-Purcell effect in the optical regime. Evanescent modes in the vicinity of a periodic grating structure can travel at the same velocity as the electrons along the grating surface. A longitudinal electric field component is used to continuously impart momentum onto the electrons. This is only possible in the near-field of a suitable photonic structure, which means that the electron beam has to pass the structure within about one wavelength. In our experiment we exploit the third spatial harmonic of a single fused silica grating excited by laser pulses derived from a Titanium:sapphire oscillator and accelerate non-relativistic 28 keV electrons. We measure a maximum energy gain of 280 eV, corresponding to an acceleration gradient of 25 MeV/m, already comparable with state-of-the-art radio-frequency linear accelerators. To experience this acceleration gradient the electrons approach the grating closer than 100 nm. We present the theory behind grating-based particle acceleration and discuss simulation results of dielectric laser acceleration in the near-field of photonic grating structures, which is excited by near-infrared laser light. Our measurements show excellent agreement with our simulation results and therefore confirm the direct acceleration with the light field. We further discuss the acceleration inside double grating structures, dephasing effects of non-relativistic electrons as well as the space charge effect, which can limit the attainable peak currents of these novel accelerator structures. The photonic structures described in this work can be readily concatenated and therefore represent a scalable realization of dielectric laser acceleration. Furthermore, our structures are directly compatible with the microstructures used for the acceleration of relativistic electrons demonstrated in parallel to this work by our collaborators in

  10. Atomic ionization of hydrogen-like ions by twisted photons: angular distribution of emitted electrons

    Science.gov (United States)

    Matula, O.; Hayrapetyan, A. G.; Serbo, V. G.; Surzhykov, A.; Fritzsche, S.

    2013-10-01

    We investigate the angular distribution of electrons that are emitted in the ionization of hydrogen-like ions by twisted photons. Analysis is performed based on the first-order perturbation theory and the non-relativistic Schrödinger equation. Special attention is paid to the dependence of the electron emission pattern on the impact parameter b of the ion with respect to the centre of the twisted wave front. In order to explore such a dependence, detailed calculations were carried out for the photoionization of the 1s ground and 2 py excited states of neutral hydrogen atoms. Based on these calculations, we argue that for relatively small impact parameters, the electron angular distributions may be strongly affected by altering the position of the atom within the wave front. In contrast, if the atom is placed far from the front centre, the emission pattern of the electrons is independent of the impact parameter b and resembles that observed in the photoionization by plane wave photons.

  11. In situ electrical and thermal monitoring of printed electronics by two-photon mapping.

    Science.gov (United States)

    Pastorelli, Francesco; Accanto, Nicolò; Jørgensen, Mikkel; van Hulst, Niek F; Krebs, Frederik C

    2017-06-19

    Printed electronics is emerging as a new, large scale and cost effective technology that will be disruptive in fields such as energy harvesting, consumer electronics and medical sensors. The performance of printed electronic devices relies principally on the carrier mobility and molecular packing of the polymer semiconductor material. Unfortunately, the analysis of such materials is generally performed with destructive techniques, which are hard to make compatible with in situ measurements, and pose a great obstacle for the mass production of printed electronics devices. A rapid, in situ, non-destructive and low-cost testing method is needed. In this study, we demonstrate that nonlinear optical microscopy is a promising technique to achieve this goal. Using ultrashort laser pulses we stimulate two-photon absorption in a roll coated polymer semiconductor and map the resulting two-photon induced photoluminescence and second harmonic response. We show that, in our experimental conditions, it is possible to relate the total amount of photoluminescence detected to important material properties such as the charge carrier density and the molecular packing of the printed polymer material, all with a spatial resolution of 400 nm. Importantly, this technique can be extended to the real time mapping of the polymer semiconductor film, even during the printing process, in which the high printing speed poses the need for equally high acquisition rates.

  12. Novel photon detection based on electronically-induced stress in silicon

    Energy Technology Data Exchange (ETDEWEB)

    Datskos, P.G. [Oak Ridge National Lab., TN (United States)]|[Univ. of Tennessee, Knoxville, TN (United States); Rajic, S.; Egert, C.M. [Oak Ridge National Lab., TN (United States); Datskou, I. [Environmental Engineering Group, Knoxville, TN (United States)

    1998-04-01

    The feasibility of microcantilever-based optical detection is demonstrated. Specifically, the authors report here on an evaluation of laboratory prototypes that are based on commercially available microcantilevers. In this work, optical transduction techniques were used to measure microcantilever response to photons and study the electronic stress in silicon microcantilevers, and their temporal and photometric response. The photo-generation of free charge carriers (electrons, holes) in a semiconductor gives rise to photo-induced (electronic) mechanical strain. The excess charge carriers responsible for the photo-induced stress, were produced via photon irradiation from a diode laser with wavelength {lambda} = 780 nm. The authors found that for silicon, the photo-induced stress results in a contraction of the crystal lattice due to the presence of excess electron-hole-pairs. In addition, the photo-induced stress is of opposite direction and about four times larger than the stress resulting from direct thermal excitation. When charge carriers are generated in a short time, a very rapid deflection of the microcantilever is observed (response time {approximately} {micro}s).

  13. Nanoporous gold synthesized by plasma-assisted inert gas condensation: room temperature sintering, nanoscale mechanical properties and stability against high energy electron irradiation

    Science.gov (United States)

    Weyrauch, S.; Wagner, C.; Suckfuell, C.; Lotnyk, A.; Knolle, W.; Gerlach, J. W.; Mayr, S. G.

    2018-02-01

    With a plasma assisted gas condensation system it is possible to achieve high-purity nanoporous Au (np-Au) structures with minimal contaminations and impurities. The structures consist of single Au-nanoparticles, which partially sintered together due to their high surface to volume ratio. Through electron microscopy investigations a porosity  >50% with ligament sizes between 20–30 nm was revealed. The elastic modulus of the np-Au was determined via peak force quantitative nanomechanical mapping and resulted in values of 7.5  ±  1.5 GPa. The presented structures partially sintered at room temperature, but proved to be stable to electron irradiation with energies of 7 MeV up to doses of 100 MGy. The electron irradiation stability opens the venue for electron assisted functionalization with biomolecules.

  14. Bethe binary-encounter peaks in the double-differential cross sections for high-energy electron-impact ionization of H2 and He

    Science.gov (United States)

    Chatterjee, S.; Agnihotri, A. N.; Stia, C. R.; Fojón, O. A.; Rivarola, R. D.; Tribedi, L. C.

    2010-11-01

    We study the Bethe binary-encounter (BE) region in the ejected-electron double-differential emission spectrum of H2 and He targets in collisions with 8-keV electrons. We compare the absolute cross sections for these isoelectronic systems at high emission energies. The experimental data are analyzed in terms of a state-of-the-art theoretical model based on a two-effective-center approximation. In the case of the H2 molecule the binary peak in the double-differential cross sections (DDCS) is enhanced due to the two-center Young-type interference. The observed undulation in the DDCS ratio is explained in terms of the combined contributions of the Compton profile mismatch and the interference effect. The influence of the interference effect is thus observed for higher-energy electrons compared to most of the earlier studies which focused on low-energy electrons produced in soft collisions.

  15. A Miniaturized Linear Wire Ion Trap with Electron Ionization and Single Photon Ionization Sources

    Science.gov (United States)

    Wu, Qinghao; Tian, Yuan; Li, Ailin; Andrews, Derek; Hawkins, Aaron R.; Austin, Daniel E.

    2017-05-01

    A linear wire ion trap (LWIT) with both electron ionization (EI) and single photon ionization (SPI) sources was built. The SPI was provided by a vacuum ultraviolet (VUV) lamp with the ability to softly ionize organic compounds. The VUV lamp was driven by a pulse amplifier, which was controlled by a pulse generator, to avoid the detection of photons during ion detection. Sample gas was introduced through a leak valve, and the pressure in the system is shown to affect the signal-to-noise ratio and resolving power. Under optimized conditions, the limit of detection (LOD) for benzene was 80 ppbv using SPI, better than the LOD using EI (137 ppbv). System performance was demonstrated by distinguishing compounds in different classes from gasoline.

  16. Direct observation of elementary radical events: low- and high-energy radiation femtochemistry in solutions

    Energy Technology Data Exchange (ETDEWEB)

    Brozek-Pluska, Beata [Institute of Applied Radiation Chemistry, Technical University of Lodz, 15 Wroblewskiego Street, 93-590 Lodz (Poland); Gliger, David; Hallou, Abdeslem [Laboratoire d' Optique Appliquee, CNRS UMR 7639, Ecole Polytechnique-ENS Techniques Avancees, 91761 Palaiseau Cedex (France); Malka, Victor; Gauduel, Yann A. [Laboratoire d' Optique Appliquee, CNRS UMR 7639, Ecole Polytechnique-ENS Techniques Avancees, 91761 Palaiseau Cedex (France)]. E-mail: yann.gauduel@ensta.fr

    2005-02-01

    The fundamental importance of understanding the primary effects of ionizing radiations in liquid phase and solutions is emphasized in fields such as electron transfer reactions, radical chemistry and radiobiology. With the advent of ultrashort optical pulses and powerful laser systems (TW lasers), ultrafast spectroscopic investigations might conjecture the direct observation of primary events induced by low-energy (photons) and high-energy (relativistic electrons) radiations. The different points discussed in this paper concern the investigation of short-time solvent caging effects on elementary radical reactions in homogeneous liquid phase and nascent spurs.

  17. A Mixed Analog-Digital Radiation Hard Technology for High Energy Physics Electronics: DMILL~(Durci~Mixte~sur~Isolant~Logico-Lineaire)

    CERN Multimedia

    Lugiez, F; Leray, J; Rouger, M; Fourches, N T; Musseau, O; Potheau, R

    2002-01-01

    %RD29 %title\\\\ \\\\Physics experiments under preparation with the future LHC require a fast, low noise, very rad-hard (>10 Mrad and >10$^{14}$ neutron/cm$^{2}$), mixed analog-digital microelectronics VLSI technology.\\\\ \\\\The DMILL microelectronics technology (RD29) was developed between 1990 and 1995 by a Consortium gathering the CEA and the firm Thomson-TCS, with the collaboration of IN2P3. The goal of the DMILL program, which is now completed, was to provide the High Energy Physics community, space industry, nuclear industry, and other applications, with an industrial very rad-hard mixed analog-digital microelectronics technology.\\\\ \\\\DMILL integrates mixed analog-digital very rad-hard (>10 Mrad and >10$^{14}$ neutron/cm$^{2}$) vertical bipolar, 0.8 $\\mu$m CMOS and 1.2 $\\mu$m PJFET transistors. Its SOI substrate and its dielectric trenches strongly reduce SEU sensitivity and completely eliminate any possibility of latch-up. Its four transistors are optimized to obtain low-noise features. DMILL also integrates...

  18. A semi-analytical model for calculating the penetration depth of a high energy electron beam in a water phantom with a magnetic field.

    Science.gov (United States)

    You, Shihu; Gou, Chengjun; Wu, Zhangwen; Hou, Qing

    2015-07-01

    As an electron beam is incident on a uniform water phantom in the presence of a lateral magnetic field, the depth-dose distribution of the electron beam changes significantly and forms the well-known 'Bragg peak', with a depth-dose distribution similar to that of heavy ions. This phenomenon has pioneered a new field in the clinical application of electron beams. For such clinical applications, evaluating the penetration depth of electron beams quickly and accurately is the critical problem. This paper describes a model for calculating the penetration depth of an electron beam rapidly and correctly in a water phantom under the influence of a magnetic field. The model was used to calculate the penetration depths under different conditions: the energies of electron beams of 6, 8, 12 and 15 MeV and the magnetic induction intensities of 0.75, 1.0, 1.5, 2.0 and 3.0 T. In addition, the calculation results were compared with the results of a Monte Carlo simulation. The comparison results indicate that the difference between the two calculation methods was less than 0.5 cm. Moreover, the computing time of the calculation model was less than a second. The semi-analytical model proposed in the present study enables the penetration depth of the electron beam in the presence of a magnetic field to be obtained with a computational efficiency higher than that of the Monte Carlo approach; thus, the proposed model has high potential for application. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  19. High energy physics

    Energy Technology Data Exchange (ETDEWEB)

    Kernan, A.; Shen, B.C.; Ma, E.

    1997-07-01

    This proposal is for the continuation of the High Energy Physics Program at the University of California, Riverside. In 1990, we will concentrate on analysis of LEP data from the OPAL detector. We expect to record 10{sup 5} Z`s by the end of 1989 and 10{sup 6} in 1990. This data will be used to measure the number of quark-lepton families in the universe. In the second half of 1990 we will also be occupied with the installation of the D-Zero detector in the Tevatron Collider and the preparation of software for the 1991 run. A new initiative made possible by generous university support is a laboratory for detector development at UCR. The focus will be on silicon strip tracking detectors both for the D-Zero upgrade and for SSC physics. The theory program will pursue further various mass-generating radiative mechanisms for understanding small quark and lepton masses as well as some novel phenomenological aspects of supersymmetry.

  20. Metallic Na formation in NaCl crystals with irradiation of electron or vacuum ultraviolet photon

    Energy Technology Data Exchange (ETDEWEB)

    Owaki, Shigehiro [Osaka Prefecture Univ., Sakai, Osaka (Japan). Coll. of Integrated Arts and Sciences; Koyama, Shigeko; Takahashi, Masao; Kamada, Masao; Suzuki, Ryouichi

    1997-03-01

    Metallic Na was formed in NaCl single crystals with irradiation of a variety of radiation sources and analyzed the physical states with several methods. In the case of irradiation of 21 MeV electron pulses to the crystal blocks, the optical absorption and lifetime measurement of positron annihilation indicated appearance of Na clusters inside. Radiation effects of electron beam of 30 keV to the crystals in vacuum showed the appearance of not only metallic Na but atomic one during irradiation with Auger electron spectroscopy. Intense photon fluxes in vacuum ultraviolet region of synchrotron radiation were used as another source and an analyzing method of ultraviolet photoelectron spectroscopy. The results showed the metallic Na layered so thick that bulk plasmon can exist. (author)

  1. arXiv Single-electron and single-photon sensitivity with a silicon Skipper CCD

    CERN Document Server

    Tiffenberg, Javier; Drlica-Wagner, Alex; Essig, Rouven; Guardincerri, Yann; Holland, Steve; Volansky, Tomer; Yu, Tien-Tien

    2017-09-26

    We have developed ultralow-noise electronics in combination with repetitive, nondestructive readout of a thick, fully depleted charge-coupled device (CCD) to achieve an unprecedented noise level of 0.068  e- rms/pixel. This is the first time that discrete subelectron readout noise has been achieved reproducible over millions of pixels on a stable, large-area detector. This enables the contemporaneous, discrete, and quantized measurement of charge in pixels, irrespective of whether they contain zero electrons or thousands of electrons. Thus, the resulting CCD detector is an ultra-sensitive calorimeter. It is also capable of counting single photons in the optical and near-infrared regime. Implementing this innovative non-destructive readout system has a negligible impact on CCD design and fabrication, and there are nearly immediate scientific applications. As a particle detector, this CCD will have unprecedented sensitivity to low-mass dark matter particles and coherent neutrino-nucleus scattering, while ...

  2. Nonlinear interaction of photons and phonons in electron-positron plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Tajima, T.; Taniuti, T.

    1990-03-01

    Nonlinear interaction of electromagnetic waves and acoustic modes in an electron-positron plasma is investigated. The plasma of electrons and positrons is quite plastic so that the imposition of electromagnetic (EM) waves causes depression of the plasma and other structural imprints on it through either the nonresonant or resonant interaction. Our theory shows that the nonresonant interaction can lead to the coalescence of photons and collapse of plasma cavity in higher ({ge} 2) dimensions. The resonant interaction, in which the group velocity of EM waves is equal to the phase velocity of acoustic waves, is analyzed and a set of basic equations of the system is derived via the reductive perturbation theory. We find new solutions of solitary types: bright solitons, kink solitons, and dark solitons as the solutions to these equations. Our computation hints their stability. An impact of the present theory on astrophysical plasma settings is expected, including the cosmological relativistically hot electron-positron plasma. 20 refs., 9 figs.

  3. Nonlinear interaction of photons and phonons in electron-positron plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Tajima, T.; Taniuti, T. (Institute for Fusion Studies, The University of Texas at Austin, Austin, TX (USA))

    1990-09-15

    Nonlinear interaction of electromagnetic waves and acoustic modes in an electron-positron plasma is investigated. The plasma of electrons and positrons is quite plastic so that the imposition of electromagnetic (em) waves causes depression of the plasma and other structural imprints on it through either the nonresonant or resonant interaction. Our theory shows that the nonresonant interaction can lead to the coalescence of photons and collapse of plasma cavity in higher ({ge}2) dimensions. The resonant interaction, in which the group velocity of em waves is equal to the phase velocity of acoustic waves, is analyzed and a set of basic equations of the system is derived via the reductive perturbation theory. We find new solutions of solitary types: bright solitons, kink solitons, and dark solitons as the solutions to these equations. An implication of the present theory on astrophysical plasma settings is suggested, including the cosmological relativistically hot electron-positron plasma.

  4. Single-photon emission associated with double electron capture in F9+ + C collisions

    CERN Document Server

    Elkafrawy, Tamer; Tanis, John A; Warczak, Andrzej

    2016-01-01

    Radiative double electron capture (RDEC), the one-step process occurring in ion-atom collisions, has been investigated for bare fluorine ions colliding with carbon. RDEC is completed when two target electrons are captured to a bound state of a projectile simultaneously with the emission of a single photon. This work is a follow-up to our earlier measurement of RDEC for bare oxygen projectiles, thus providing a recipient system free of electron-related Coulomb fields in both cases and allowing for the comparison between the two collision systems as well as with available theoretical studies. The most significant mechanisms of x-ray emission that may contribute to the RDEC energy region as background processes are also addressed.

  5. New calculations and measurements of the Coulomb cross-section for the production of direct electron pairs by high energy nuclei

    Science.gov (United States)

    Derrickson, J. H.; Dake, S.; Dong, B. L.; Eby, P. B.; Fountain, W. F.; Fuki, M.; Gregory, J. C.; Hayashi, T.; Iyono, A.; King, D. T.

    1989-01-01

    Recently, new calculations were made of the direct Coulomb pair cross section that rely less in arbitrary parameters. More accurate calculations of the cross section down to low pair energies were made. New measurements of the total direct electron pair yield, and the energy and angular distribution of the electron pairs in emulsion were made for O-16 at 60 and 200 GeV/amu at S-32 at 200 GeV/amu which give satisfactory agreement with the new calculations. These calculations and measurements are presented along with previous accelerator measurements made of this effect during the last 40 years. The microscope scanning criteria used to identify the direct electron pairs is described. Prospects for application of the pair method to cosmic ray energy measurements in the region 10 (exp 13) to 10 (exp 15) eV/amu are discussed.

  6. Evaluation of Electron Contamination in Cancer Treatment with Megavoltage Photon Beams: Monte Carlo Study

    Directory of Open Access Journals (Sweden)

    Seif F

    2015-03-01

    Full Text Available Background: Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in optimization of linac head materials. The aim of this study was to calculate electron contamination of Varian linac. Materials and Method: The 6MV photon beam of Varian (2100 C/D linac was simulated by Monte Carlo code, MCNPX, based on its company’s instructions. The validation was done by comparing the calculated depth dose and profiles of simulation with dosimetry measurements in a water phantom (error less than 2%. The Percentage Depth Dose (PDDs, profiles and contamination electron energy spectrum were calculated for different therapeutic field sizes (5×5 to 40×40 cm2 for both linacs. Results: The dose of electron contamination was observed to rise with increase in field size. The contribution of the secondary contamination electrons on the surface dose was 6% for 5×5 cm2 to 27% for 40×40 cm2 , respectively. Conclusion: Based on the results, the effect of electron contamination on patient surface dose cannot be ignored, so the knowledge of the electron contamination is important in clinical dosimetry. It must be calculated for each machine and considered in Treatment Planning Systems.

  7. Radiation dose enhancement in skin therapy with nanoparticle addition: A Monte Carlo study on kilovoltage photon and megavoltage electron beams.

    Science.gov (United States)

    Zheng, Xiao J; Chow, James C L

    2017-02-28

    To investigated the dose enhancement due to the incorporation of nanoparticles in skin therapy using the kilovoltage (kV) photon and megavoltage (MV) electron beams. Monte Carlo simulations were used to predict the dose enhancement when different types and concentrations of nanoparticles were added to skin target layers of varying thickness. Clinical kV photon beams (105 and 220 kVp) and MV electron beams (4 and 6 MeV), produced by a Gulmay D3225 orthovoltage unit and a Varian 21 EX linear accelerator, were simulated using the EGSnrc Monte Carlo code. Doses at skin target layers with thicknesses ranging from 0.5 to 5 mm for the photon beams and 0.5 to 10 mm for the electron beams were determined. The skin target layer was added with the Au, Pt, I, Ag and Fe 2 O 3 nanoparticles with concentrations ranging from 3 to 40 mg/mL. The dose enhancement ratio (DER), defined as the dose at the target layer with nanoparticle addition divided by the dose at the layer without nanoparticle addition, was calculated for each nanoparticle type, nanoparticle concentration and target layer thickness. It was found that among all nanoparticles, Au had the highest DER (5.2-6.3) when irradiated with kV photon beams. Dependence of the DER on the target layer thickness was not significant for the 220 kVp photon beam but it was for 105 kVp beam for Au nanoparticle concentrations higher than 18 mg/mL. For other nanoparticles, the DER was dependent on the atomic number of the nanoparticle and energy spectrum of the photon beams. All nanoparticles showed an increase of DER with nanoparticle concentration during the photon beam irradiations regardless of thickness. For electron beams, the Au nanoparticles were found to have the highest DER (1.01-1.08) when the beam energy was equal to 4 MeV, but this was drastically lower than the DER values found using photon beams. The DER was also found affected by the depth of maximum dose of the electron beam and target thickness. For other nanoparticles

  8. Comparative Analysis of NOAA REFM and SNB3GEO Tools for the Forecast of the Fluxes of High-Energy Electrons at GEO

    Science.gov (United States)

    Balikhin, M. A.; Rodriguez, J. V.; Boynton, R. J.; Walker, S. N.; Aryan, Homayon; Sibeck, D. G.; Billings, S. A.

    2016-01-01

    Reliable forecasts of relativistic electrons at geostationary orbit (GEO) are important for the mitigation of their hazardous effects on spacecraft at GEO. For a number of years the Space Weather Prediction Center at NOAA has provided advanced online forecasts of the fluence of electrons with energy >2 MeV at GEO using the Relativistic Electron Forecast Model (REFM). The REFM forecasts are based on real-time solar wind speed observations at L1. The high reliability of this forecasting tool serves as a benchmark for the assessment of other forecasting tools. Since 2012 the Sheffield SNB3GEO model has been operating online, providing a 24 h ahead forecast of the same fluxes. In addition to solar wind speed, the SNB3GEO forecasts use solar wind density and interplanetary magnetic field B(sub z) observations at L1. The period of joint operation of both of these forecasts has been used to compare their accuracy. Daily averaged measurements of electron fluxes by GOES 13 have been used to estimate the prediction efficiency of both forecasting tools. To assess the reliability of both models to forecast infrequent events of very high fluxes, the Heidke skill score was employed. The results obtained indicate that SNB3GEO provides a more accurate 1 day ahead forecast when compared to REFM. It is shown that the correction methodology utilized by REFM potentially can improve the SNB3GEO forecast.

  9. Changes of the Electrical and Optical Character of Polyimide Films (and the Chemistry that Drives Them) Due to Exposure to High Energy GEO-like Electrons

    Science.gov (United States)

    2015-10-18

    electrical conduction of aluminized polyimide film after simulated aging in a GEO-like electron environment. We correlate these data with the chemical...and D. Yang, "Damage effect of keV proton irradiation on aluminized Kapton film," Radiation Physics and Chemistry, vol. 77, pp. 482-489, 2008. [21] T

  10. Orthogonal sequencing multiplexer for superconducting nanowire single-photon detectors with RSFQ electronics readout circuit.

    Science.gov (United States)

    Hofherr, Matthias; Wetzstein, Olaf; Engert, Sonja; Ortlepp, Thomas; Berg, Benjamin; Ilin, Konstantin; Henrich, Dagmar; Stolz, Ronny; Toepfer, Hannes; Meyer, Hans-Georg; Siegel, Michael

    2012-12-17

    We propose an efficient multiplexing technique for superconducting nanowire single-photon detectors based on an orthogonal detector bias switching method enabling the extraction of the average count rate of a set of detectors by one readout line. We implemented a system prototype where the SNSPDs are connected to an integrated cryogenic readout and a pulse merger system based on rapid single flux quantum (RSFQ) electronics. We discuss the general scalability of this concept, analyze the environmental requirements which define the resolvability and the accuracy and demonstrate the feasibility of this approach with experimental results for a SNSPD array with four pixels.

  11. Two-electron double quantum dot coupled to coherent photon and phonon fields

    Science.gov (United States)

    Sato, Yuya; Chen, Jason C. H.; Hashisaka, Masayuki; Muraki, Koji; Fujisawa, Toshimasa

    2017-09-01

    Two-electron states of a double quantum dot (DQD) under irradiation of coherent boson (photon and phonon) fields are studied by measuring spin-flip tunneling current in the Pauli spin blockade regime. This measurement scheme allows us to investigate Rabi splitting and associated boson dressed states particularly in the deep dispersive regime where the detuning δ ≡ℏ ω -EAB between the boson energy ℏ ω and energy spacing EAB of the two-level system is significantly large (δ ˜ℏ ω ), where the permanent dipole moment in the DQD plays a significant role in the hybridization.

  12. The CMS electron and photon trigger for the LHC Run 2

    Science.gov (United States)

    Dezoort, Gage; Xia, Fan

    2017-01-01

    The CMS experiment implements a sophisticated two-level triggering system composed of Level-1, instrumented by custom-design hardware boards, and a software High-Level-Trigger. A new Level-1 trigger architecture with improved performance is now being used to maintain the thresholds that were used in LHC Run I for the more challenging luminosity conditions experienced during Run II. The upgrades to the calorimetry trigger will be described along with performance data. The algorithms for the selection of final states with electrons and photons, both for precision measurements and for searches of new physics beyond the Standard Model, will be described in detail.

  13. Vertical instability with transient characteristics in KEK-Photon Factory electron storage ring

    Directory of Open Access Journals (Sweden)

    A. Mochihashi

    2001-02-01

    Full Text Available A vertical instability of the KEK-Photon Factory electron storage ring was observed in a multibunch mode with empty buckets (bunch gap using a bunch-by-bunch beam diagnostic system that consisted of a high-speed light shutter and an optical betatron oscillation detector. It was clearly seen that vertical betatron frequencies of individual bunches varied along a bunch train. The dependence of the betatron frequencies on the bunch positions in the train was explained by modulation of trapped-ion density caused by passage of the beam. Agreement between experimental results and the theoretical prediction was quite good.

  14. Angular correlations of photons from solution diffraction at a free-electron laser encode molecular structure

    Directory of Open Access Journals (Sweden)

    Derek Mendez

    2016-11-01

    Full Text Available During X-ray exposure of a molecular solution, photons scattered from the same molecule are correlated. If molecular motion is insignificant during exposure, then differences in momentum transfer between correlated photons are direct measurements of the molecular structure. In conventional small- and wide-angle solution scattering, photon correlations are ignored. This report presents advances in a new biomolecular structural analysis technique, correlated X-ray scattering (CXS, which uses angular intensity correlations to recover hidden structural details from molecules in solution. Due to its intense rapid pulses, an X-ray free electron laser (XFEL is an excellent tool for CXS experiments. A protocol is outlined for analysis of a CXS data set comprising a total of half a million X-ray exposures of solutions of small gold nanoparticles recorded at the Spring-8 Ångström Compact XFEL facility (SACLA. From the scattered intensities and their correlations, two populations of nanoparticle domains within the solution are distinguished: small twinned, and large probably non-twinned domains. It is shown analytically how, in a solution measurement, twinning information is only accessible via intensity correlations, demonstrating how CXS reveals atomic-level information from a disordered solution of like molecules.

  15. New analytical model for the ozone electronic ground state potential surface and accurate ab initio vibrational predictions at high energy range.

    Science.gov (United States)

    Tyuterev, Vladimir G; Kochanov, Roman V; Tashkun, Sergey A; Holka, Filip; Szalay, Péter G

    2013-10-07

    An accurate description of the complicated shape of the potential energy surface (PES) and that of the highly excited vibration states is of crucial importance for various unsolved issues in the spectroscopy and dynamics of ozone and remains a challenge for the theory. In this work a new analytical representation is proposed for the PES of the ground electronic state of the ozone molecule in the range covering the main potential well and the transition state towards the dissociation. This model accounts for particular features specific to the ozone PES for large variations of nuclear displacements along the minimum energy path. The impact of the shape of the PES near the transition state (existence of the "reef structure") on vibration energy levels was studied for the first time. The major purpose of this work was to provide accurate theoretical predictions for ozone vibrational band centres at the energy range near the dissociation threshold, which would be helpful for understanding the very complicated high-resolution spectra and its analyses currently in progress. Extended ab initio electronic structure calculations were carried out enabling the determination of the parameters of a minimum energy path PES model resulting in a new set of theoretical vibrational levels of ozone. A comparison with recent high-resolution spectroscopic data on the vibrational levels gives the root-mean-square deviations below 1 cm(-1) for ozone band centres up to 90% of the dissociation energy. New ab initio vibrational predictions represent a significant improvement with respect to all previously available calculations.

  16. Hybrid fluorescence and electron cryo-microscopy for simultaneous electron and photon imaging.

    Science.gov (United States)

    Iijima, Hirofumi; Fukuda, Yoshiyuki; Arai, Yoshihiro; Terakawa, Susumu; Yamamoto, Naoki; Nagayama, Kuniaki

    2014-01-01

    Integration of fluorescence light and transmission electron microscopy into the same device would represent an important advance in correlative microscopy, which traditionally involves two separate microscopes for imaging. To achieve such integration, the primary technical challenge that must be solved regards how to arrange two objective lenses used for light and electron microscopy in such a manner that they can properly focus on a single specimen. To address this issue, both lateral displacement of the specimen between two lenses and specimen rotation have been proposed. Such movement of the specimen allows sequential collection of two kinds of microscopic images of a single target, but prevents simultaneous imaging. This shortcoming has been made up by using a simple optical device, a reflection mirror. Here, we present an approach toward the versatile integration of fluorescence and electron microscopy for simultaneous imaging. The potential of simultaneous hybrid microscopy was demonstrated by fluorescence and electron sequential imaging of a fluorescent protein expressed in cells and cathodoluminescence imaging of fluorescent beads. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Electrons and photons at High Level Trigger in CMS for Run II

    CERN Document Server

    Bin Anuar, Afiq Aizuddin

    2015-01-01

    The CMS experiment has been designed with a 2-level trigger system. The first level is implemented using custom-designed electronics. The second level is the so-called High Level Trigger (HLT), a streamlined version of the CMS offline reconstruction software running on a computer farm. For Run II of the Large Hadron Collider, the increase in center-of-mass energy and luminosity will raise the event rate to a level challenging for the HLT algorithms. New approaches have been studied to keep the HLT output rate manageable while maintaining thresholds low enough to cover physics analyses. The strategy mainly relies on porting online the ingredients that have been successfully applied in the offline reconstruction, thus allowing to move HLT selection closer to offline cuts. Improvements in HLT electron and photon definitions will be presented, focusing in particular on updated clustering algorithm and the energy calibration procedure, new Particle-Flow-based isolation approach and pileup mitigation techniques, a...

  18. penORNL: a parallel Monte Carlo photon and electron transport package using PENELOPE

    Energy Technology Data Exchange (ETDEWEB)

    Bekar, Kursat B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Miller, Thomas Martin [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Patton, Bruce W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Weber, Charles F. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    The parallel Monte Carlo photon and electron transport code package penORNL was developed at Oak Ridge National Laboratory to enable advanced scanning electron microscope (SEM) simulations on high-performance computing systems. This paper discusses the implementations, capabilities and parallel performance of the new code package. penORNL uses PENELOPE for its physics calculations and provides all available PENELOPE features to the users, as well as some new features including source definitions specifically developed for SEM simulations, a pulse-height tally capability for detailed simulations of gamma and x-ray detectors, and a modified interaction forcing mechanism to enable accurate energy deposition calculations. The parallel performance of penORNL was extensively tested with several model problems, and very good linear parallel scaling was observed with up to 512 processors. penORNL, along with its new features, will be available for SEM simulations upon completion of the new pulse-height tally implementation.

  19. Multivariate Analysis in the Reconstruction of Photon/Electron Energies in the CMS

    CERN Document Server

    Raclariu, Ana-Maria

    2013-01-01

    A new semi-parametric multivariate regression was used to improve the energy reconstruction in the CMS electromagnetic calorimeter. The method is based on the generation of boosted decision trees by optimizing the parameters of the double crystal ball function fitted to the ratio of the raw to generated energies of simulated photons and electrons. The full training was done on half the electrons with generated transverse momenta p$_{T}\\geq$ 16 GeV in the barrel and corrections were applied to subsets of the remaining events. The dependence of the means and widths of the resulting distributions on p$_{T}$ was deduced. The corrected reconstructed energies peak close 1 for p$_{T}$ values down to 16 GeV. It was found that fixing $\\alpha$ of the double crystal ball function in the training improves its performance.

  20. Study of the electronphoton misidentification rate in the ATLAS detector

    CERN Document Server

    Haase, Johannes

    In this thesis, the misidentification of electrons as photons (fake rate) is investigated using the first 7 TeV data of the ATLAS detector at the CERN Large Hadron Collider. A method for the measurement of the fake rate in data, using pure electrons from the Z0 → e+e− decay, called tag-and-probe, is presented. The results are studied as functions of kinematic variables in order to show effects on the detector performance. A cross check with a so-called truth-matching method in Monte Carlo is applied. In addition, the fake rate for Gauge Mediated Supersymmetry Breaking events is estimated and compared with Z0 → e+e− studies.

  1. Parallel FE Electron-Photon Transport Analysis on 2-D Unstructured Mesh

    Energy Technology Data Exchange (ETDEWEB)

    Drumm, C.R.; Lorenz, J.

    1999-03-02

    A novel solution method has been developed to solve the coupled electron-photon transport problem on an unstructured triangular mesh. Instead of tackling the first-order form of the linear Boltzmann equation, this approach is based on the second-order form in conjunction with the conventional multi-group discrete-ordinates approximation. The highly forward-peaked electron scattering is modeled with a multigroup Legendre expansion derived from the Goudsmit-Saunderson theory. The finite element method is used to treat the spatial dependence. The solution method is unique in that the space-direction dependence is solved simultaneously, eliminating the need for the conventional inner iterations, a method that is well suited for massively parallel computers.

  2. Unique properties of graphene quantum dots and their applications in photonic/electronic devices

    Science.gov (United States)

    Choi, Suk-Ho

    2017-03-01

    In recent years, graphene quantum dots (GQDs) have been recognized as an attractive building block for electronic, photonic, and bio-molecular device applications. This paper reports the current status of studies on the novel properties of GQDs and their hybrids with conventional and low-dimensional materials for device applications. In this review, more emphasis is placed on the structural, electronic, and optical properties of GQDs, and device structures based on the combination of GQDs with various semiconducting/insulating materials such as graphene, silicon dioxide, Si quantum dots, silica nanoparticles, organic materials, and so on. Because of GQDs’ unique properties, their hybrid structures are employed in high-efficiency devices, including photodetectors, solar cells, light-emitting diodes, flash memory, and sensors.

  3. Electron and photon energy reconstruction in the electromagnetic calorimeter of ATLAS

    CERN Document Server

    AUTHOR|(CDS)2075753; Mandelli, Luciano

    2007-01-01

    The Atlas LAr electromagnetic calorimeter is designed to provide a precise measurement of electrons and photons energies, in order to meet the requirements coming from the LHC physics program. This request of precision makes important to understand the behavior of the detector in all its aspect. Of fundamental importance to achieve the best possible performances is the calibration of the EM calorimeter, and this is the topic of this thesis. With detailed Monte Carlo simulations of single electrons and photons in the Atlas detector, we find a method to calibrate the electromagnetic calorimeter, based only on the informations that come from it. All the informations needed to develop a calibration method come from the simulations made with the technique of the Calibration Hits, that allows to know the en- ergy deposited in all the materials inside the detector volume, and not only in the active layer of each subdetector as possible in the standard simulations. This technique required a big effort for the develop...

  4. Coplanar photonic bandgap resonators for low temperature electron and nuclear magnetic resonance spectroscopy

    Science.gov (United States)

    Sigillito, A. J.; Tyryshkin, A. M.; Lyon, S. A.

    In recent years, superconducting coplanar waveguide (CPW) resonators have become a useful tool for low temperature pulsed electron spin resonance (ESR), even at dilution refrigerator temperatures. Their small mode volumes make CPW resonators particularly well suited to measuring small numbers of spins near the resonator surface, since in this region the spin sensitivity is very high. While these resonators have proven useful for ESR at single microwave frequencies, it is difficult to also manipulate nuclear spins in electron-nuclear-double resonance (ENDOR) experiments, since manipulation of nuclear spins requires radio frequency (RF) magnetic fields. Ideally one would simply generate these fields by passing RF currents through the CPW, but because conventional CPW resonators are capacitively coupled, they will not transmit low-frequency RF currents. In this talk, we discuss the use of one dimensional photonic bandgap (PBG) resonators to overcome this challenge. PBG resonators are a promising alternative to conventional CPW resonators since they offer high quality factors at microwave frequencies, while simultaneously allowing transmission of nonresonant RF currents below the photonic bandgap. Here, we will discuss PBG resonator designs and present data showing their use for low temperature ESR of donors in 28Si. Initial ENDOR results will also be presented.

  5. ITS Version 6 : the integrated TIGER series of coupled electron/photon Monte Carlo transport codes.

    Energy Technology Data Exchange (ETDEWEB)

    Franke, Brian Claude; Kensek, Ronald Patrick; Laub, Thomas William

    2008-04-01

    ITS is a powerful and user-friendly software package permitting state-of-the-art Monte Carlo solution of lineartime-independent coupled electron/photon radiation transport problems, with or without the presence of macroscopic electric and magnetic fields of arbitrary spatial dependence. Our goal has been to simultaneously maximize operational simplicity and physical accuracy. Through a set of preprocessor directives, the user selects one of the many ITS codes. The ease with which the makefile system is applied combines with an input scheme based on order-independent descriptive keywords that makes maximum use of defaults and internal error checking to provide experimentalists and theorists alike with a method for the routine but rigorous solution of sophisticated radiation transport problems. Physical rigor is provided by employing accurate cross sections, sampling distributions, and physical models for describing the production and transport of the electron/photon cascade from 1.0 GeV down to 1.0 keV. The availability of source code permits the more sophisticated user to tailor the codes to specific applications and to extend the capabilities of the codes to more complex applications. Version 6, the latest version of ITS, contains (1) improvements to the ITS 5.0 codes, and (2) conversion to Fortran 90. The general user friendliness of the software has been enhanced through memory allocation to reduce the need for users to modify and recompile the code.

  6. A Gas Calorimeter for High-Energy Experiment and Study of High-Energy Cascade Shower

    Energy Technology Data Exchange (ETDEWEB)

    Miyata, Hitoshi [Tsukuba U.

    1984-01-01

    High energy behavior of the electromagnetic cascade shower has been studied. high energy showers were created by electron and hadron beams with energies between 25 GeV and 150 GeV at Fermi National Accelerator Laboratory. The showers were observed by a shower detector consisting of multi-layer of lead plates and proportional chambers. The experimental results were analyzed with special emphasis on the fluctuation problem of the electromagnetic cascade shower....

  7. The Photon-Assisted Cascaded Electron Multiplier Operation in CF4 for Ion Backflow Suppression

    Science.gov (United States)

    Amaro, F. D.; Veloso, J. F. C. A.; dos Santos, J. M. F.; Breskin, A.; Chechik, R.; Lyashenko, A.

    2008-06-01

    The operation of the recently introduced photon assisted cascaded electron multiplier (PACEM) in CF4 is investigated. The PACEM uses the VUV scintillation produced in the electron avalanches of the first multiplier of the cascade to transfer the signal to the subsequent ones. The VUV scintillation induces the emission of a large number of photoelectrons from a Csl photocathode placed on the top-surface of the second multiplier. The photoelectrons are further multiplied in the subsequent stages of the cascade, resulting in efficient signal amplification. A mesh, set at a fixed voltage, is placed between the first and the second multipliers to block the charge transfer between them, thus suppressing all the ion backflow (IBF) heading to the first cascade element. The PACEM electrically isolates the first multiplier of the cascade and only the ions produced in the electron avalanches of the first element may flow back into the drift region. Operating in CF4, absolute IBFs as low as 1 ion per primary electron are achieved for drift fields of 0.1 kV/cm, while for fields of 0.5 kV/cm the absolute IBF is 10 ions/primary electron. This corresponds to an IBF of 10-4 at gains of 104, for time projection chambers (TPC) operating conditions, and IBFs of 10-5 at gains of 106 for gaseous photomultipliers (GPM) operating conditions.

  8. High-potential perfluorinated phthalocyanine-fullerene dyads for generation of high-energy charge-separated states: formation and photoinduced electron-transfer studies.

    Science.gov (United States)

    Das, Sushanta K; Mahler, Andrew; Wilson, Angela K; D'Souza, Francis

    2014-08-25

    High oxidation potential perfluorinated zinc phthalocyanines (ZnF(n)Pcs) are synthesised and their spectroscopic, redox, and light-induced electron-transfer properties investigated systematically by forming donor-acceptor dyads through metal-ligand axial coordination of fullerene (C60) derivatives. Absorption and fluorescence spectral studies reveal efficient binding of the pyridine- (Py) and phenylimidazole-functionalised fullerene (C60Im) derivatives to the zinc centre of the F(n)Pcs. The determined binding constants, K, in o-dichlorobenzene for the 1:1 complexes are in the order of 10(4) to 10(5) M(-1); nearly an order of magnitude higher than that observed for the dyad formed from zinc phthalocyanine (ZnPc) lacking fluorine substituents. The geometry and electronic structure of the dyads are determined by using the B3LYP/6-31G* method. The HOMO and LUMO levels are located on the Pc and C60 entities, respectively; this suggests the formation of ZnF(n)Pc(.+)-C60Im(.-) and ZnF(n)Pc(.+)-C60Py(.-) (n=0, 8 or 16) intra-supramolecular charge-separated states during electron transfer. Electrochemical studies on the ZnPc-C60 dyads enable accurate determination of their oxidation and reduction potentials and the energy of the charge-separated states. The energy of the charge-separated state for dyads composed of ZnF(n)Pc is higher than that of normal ZnPc-C60 dyads and reveals their significance in harvesting higher amounts of light energy. Evidence for charge separation in the dyads is secured from femtosecond transient absorption studies in nonpolar toluene. Kinetic evaluation of the cation and anion radical ion peaks reveals ultrafast charge separation and charge recombination in dyads composed of perfluorinated phthalocyanine and fullerene; this implies their significance in solar-energy harvesting and optoelectronic device building applications. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Effects of model approximations for electron, hole, and photon transport in swift heavy ion tracks

    Science.gov (United States)

    Rymzhanov, R. A.; Medvedev, N. A.; Volkov, A. E.

    2016-12-01

    The event-by-event Monte Carlo code, TREKIS, was recently developed to describe excitation of the electron subsystems of solids in the nanometric vicinity of a trajectory of a nonrelativistic swift heavy ion (SHI) decelerated in the electronic stopping regime. The complex dielectric function (CDF) formalism was applied in the used cross sections to account for collective response of a matter to excitation. Using this model we investigate effects of the basic assumptions on the modeled kinetics of the electronic subsystem which ultimately determine parameters of an excited material in an SHI track. In particular, (a) effects of different momentum dependencies of the CDF on scattering of projectiles on the electron subsystem are investigated. The 'effective one-band' approximation for target electrons produces good coincidence of the calculated electron mean free paths with those obtained in experiments in metals. (b) Effects of collective response of a lattice appeared to dominate in randomization of electron motion. We study how sensitive these effects are to the target temperature. We also compare results of applications of different model forms of (quasi-) elastic cross sections in simulations of the ion track kinetics, e.g. those calculated taking into account optical phonons in the CDF form vs. Mott's atomic cross sections. (c) It is demonstrated that the kinetics of valence holes significantly affects redistribution of the excess electronic energy in the vicinity of an SHI trajectory as well as its conversion into lattice excitation in dielectrics and semiconductors. (d) It is also shown that induced transport of photons originated from radiative decay of core holes brings the excess energy faster and farther away from the track core, however, the amount of this energy is relatively small.

  10. Towards Attosecond High-Energy Electron Bunches: Controlling Self-Injection in Laser-Wakefield Accelerators Through Plasma-Density Modulation

    Science.gov (United States)

    Tooley, M. P.; Ersfeld, B.; Yoffe, S. R.; Noble, A.; Brunetti, E.; Sheng, Z. M.; Islam, M. R.; Jaroszynski, D. A.

    2017-07-01

    Self-injection in a laser-plasma wakefield accelerator is usually achieved by increasing the laser intensity until the threshold for injection is exceeded. Alternatively, the velocity of the bubble accelerating structure can be controlled using plasma density ramps, reducing the electron velocity required for injection. We present a model describing self-injection in the short-bunch regime for arbitrary changes in the plasma density. We derive the threshold condition for injection due to a plasma density gradient, which is confirmed using particle-in-cell simulations that demonstrate injection of subfemtosecond bunches. It is shown that the bunch charge, bunch length, and separation of bunches in a bunch train can be controlled by tailoring the plasma density profile.

  11. Dosimetry of high energy radiation

    CERN Document Server

    Sahare, P D

    2018-01-01

    High energy radiation is hazardous to living beings and a threat to mankind. The correct estimation of the high energy radiation is a must and a single technique may not be very successful. The process of estimating the dose (the absorbed energy that could cause damages) is called dosimetry. This book covers the basic technical knowledge in the field of radiation dosimetry. It also makes readers aware of the dangers and hazards of high energy radiation.

  12. Photon counting imaging with an electron-bombarded CCD: Towards a parallel-processing photoelectronic time-to-amplitude converter

    Energy Technology Data Exchange (ETDEWEB)

    Hirvonen, Liisa M.; Jiggins, Stephen; Sergent, Nicolas; Zanda, Gianmarco; Suhling, Klaus, E-mail: klaus.suhling@kcl.ac.uk [Department of Physics, King' s College London, Strand, London WC2R 2LS (United Kingdom)

    2014-12-15

    We have used an electron-bombarded CCD for optical photon counting imaging. The photon event pulse height distribution was found to be linearly dependent on the gain voltage. We propose on this basis that a gain voltage sweep during exposure in an electron-bombarded sensor would allow photon arrival time determination with sub-frame exposure time resolution. This effectively uses an electron-bombarded sensor as a parallel-processing photoelectronic time-to-amplitude converter, or a two-dimensional photon counting streak camera. Several applications that require timing of photon arrival, including Fluorescence Lifetime Imaging Microscopy, may benefit from such an approach. A simulation of a voltage sweep performed with experimental data collected with different acceleration voltages validates the principle of this approach. Moreover, photon event centroiding was performed and a hybrid 50% Gaussian/Centre of Gravity + 50% Hyperbolic cosine centroiding algorithm was found to yield the lowest fixed pattern noise. Finally, the camera was mounted on a fluorescence microscope to image F-actin filaments stained with the fluorescent dye Alexa 488 in fixed cells.

  13. High energy particles and quanta in astrophysics

    Science.gov (United States)

    Mcdonald, F. B. (Editor); Fichtel, C. E.

    1974-01-01

    The various subdisciplines of high-energy astrophysics are surveyed in a series of articles which attempt to give an overall view of the subject as a whole by emphasizing the basic physics common to all fields in which high-energy particles and quanta play a role. Successive chapters cover cosmic ray experimental observations, the abundances of nuclei in the cosmic radiation, cosmic electrons, solar modulation, solar particles (observation, relationship to the sun acceleration, interplanetary medium), radio astronomy, galactic X-ray sources, the cosmic X-ray background, and gamma ray astronomy. Individual items are announced in this issue.

  14. Evaluation of the effect of tooth and dental restoration material on electron dose distribution and production of photon contamination in electron beam radiotherapy.

    Science.gov (United States)

    Bahreyni Toossi, Mohammad Taghi; Ghorbani, Mahdi; Akbari, Fatemeh; Mehrpouyan, Mohammad; Sobhkhiz Sabet, Leila

    2016-03-01

    The aim of this study is to evaluate the effect of tooth and dental restoration materials on electron dose distribution and photon contamination production in electron beams of a medical linac. This evaluation was performed on 8, 12 and 14 MeV electron beams of a Siemens Primus linac. MCNPX Monte Carlo code was utilized and a 10 × 10 cm(2) applicator was simulated in the cases of tooth and combinations of tooth and Ceramco C3 ceramic veneer, tooth and Eclipse alloy and tooth and amalgam restoration materials in a soft tissue phantom. The relative electron and photon contamination doses were calculated for these materials. The presence of tooth and dental restoration material changed the electron dose distribution and photon contamination in phantom, depending on the type of the restoration material and electron beam's energy. The maximum relative electron dose was 1.07 in the presence of tooth including amalgam for 14 MeV electron beam. When 100.00 cGy was prescribed for the reference point, the maximum absolute electron dose was 105.10 cGy in the presence of amalgam for 12 MeV electron beam and the maximum absolute photon contamination dose was 376.67 μGy for tooth in 14 MeV electron beam. The change in electron dose distribution should be considered in treatment planning, when teeth are irradiated in electron beam radiotherapy. If treatment planning can be performed in such a way that the teeth are excluded from primary irradiation, the potential errors in dose delivery to the tumour and normal tissues can be avoided.

  15. Effect of high energy electron beam (10MeV) on specific heat capacity of low-density polyethylene/hydroxyapatite nano-composite.

    Science.gov (United States)

    Soltani, Z; Ziaie, F; Ghaffari, M; Beigzadeh, A M

    2017-02-01

    In the present work, thermal properties of low density polyethylene (LDPE) and its nano composites are investigated. For this purpose LDPE reinforced with different weight percents of hydroxyapatite (HAP) powder which was synthesized via hydrolysis method are produced. The samples were irradiated with 10MeV electron beam at doses of 75 to 250kGy. Specific heat capacity measurement have been carried out at different temperatures, i.e. 25, 50, 75 and 100°C using modulated temperature differential scanning calorimetry (MTDSC) apparatus and the effect of three parameters include of temperature, irradiation dose and the amount of HAP nano particles as additives on the specific heat capacity of PE/HAP have been investigated precisely. The MTDSC results indicate that the specific heat capacity have decreased by addition of nano sized HAP as reinforcement for LDPE. On the other hand, the effect of radiation dose is reduction in the specific heat capacity in all materials including LDPE and its nano composites. The HAP nano particles along with cross-link junctions due to radiation restrain the movement of the polymer chains in the vicinity of each particle and improve the immobility of polymer chains and consequently lead to reduction in specific heat capacity. Also, the obtained results confirm that the radiation effect on the specific heat capacity is more efficient than the reinforcing effect of nano-sized hydroxyapatite. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. High Energy Gamma-rays from FR I Jets

    CERN Document Server

    Sikora, M

    2003-01-01

    Thanks to Hubble and Chandra telescopes, some of the large scale jets in extragalactic radio sources are now being observed at optical and X-ray frequencies. For the FR I objects the synchrotron nature of this emission is surely established, although a lot of uncertainties--connected for example with the particle acceleration processes involved--remain. In this paper we study production of high energy gamma-rays in FR I kiloparsec-scale jets by inverse-Compton emission of the synchrotron-emitting electrons. We consider different origin of seed photons contributing to the inverse-Compton scattering, including nuclear jet radiation as well as ambient, stellar and circumstellar emission of the host galaxies. We discuss how future detections or non-detections of the evaluated gamma-ray fluxes can provide constraints on the unknown large scale jet parameters, i.e. the magnetic field intensity and the jet Doppler factor. For the nearby sources Centaurus A and M 87, we find measurable fluxes of TeV photons resulting...

  17. A BaF2 crystal array for high energy -ray measurements

    Indian Academy of Sciences (India)

    The measurement of high energy 7-ray photons is an important area of current research in nuclear physics. The high energy 7-rays from GDR decay gives us valuable information about the shape of nuclei and equation of state of nuclear matter. The high energy 7-rays above GDR 7-ray energy are primarily produced due to ...

  18. High energy physics

    Energy Technology Data Exchange (ETDEWEB)

    1992-04-10

    The Counter Group continues to work on data analysis for Fermilab Experiment E653. Altogether, they expect several thousand reconstructed charm events and approximately 25 B pair events of which 12 have been observed thus far. Preparation continue for Fermilab Experiment E781, a high statistics study of charm baryon production. In the Theory Group, Cutkosky and collaborators study hadron phenomenology and non-perturbative QCD calculations. Levine has a long standing program in computational QED to obtain improved theoretical values for g-2 of the electron. Wolfenstein, Li, and their collaborators have worked on areas of weak interaction phenomenology that may yield insights beyond the standard model, e.g. CP violation and non-zero neutrino masses. Holman has been concerned with phase transitions in gauge theories relevant to cosmological problems. During 1991 most of the group effort was concentrated on the L3 experiment at CERN. Highlights of the results from the analysis of the Z[degrees] resonance include (a) a measurement of the strong coupling constant [alpha][sub s] for b quarks (b) a precision measurement of the average time of B hadrons and (c) a direct determination of the number of light neutrino faculties from the reaction e[sup +]e[sup [minus

  19. Single-electron and single-photon sensitivity with a silicon Skipper CCD

    Energy Technology Data Exchange (ETDEWEB)

    Tiffenberg, Javier [Fermilab; Sofo-Haro, Miguel [Balseiro Inst., San Carlos de Bariloche; Drlica-Wagner, Alex [Fermilab; Essig, Rouven [YITP, Stony Brook; Guardincerri, Yann [Fermilab; Holland, Steve [LBL, Berkeley; Volansky, Tomer [Tel Aviv U.; Yu, Tien-Tien [CERN

    2017-05-31

    We have developed a non-destructive readout system that uses a floating-gate amplifier on a thick, fully depleted charge coupled device (CCD) to achieve ultra-low readout noise of 0.068 e- rms/pix. This is the first time that discrete sub-electron readout noise has been achieved reproducibly over millions of pixels on a stable, large-area detector. This allows the precise counting of the number of electrons in each pixel, ranging from pixels with 0 electrons to more than 1500 electrons. The resulting CCD detector is thus an ultra-sensitive calorimeter. It is also capable of counting single photons in the optical and near-infrared regime. Implementing this innovative non-destructive readout system has a negligible impact on CCD design and fabrication, and there are nearly immediate scientific applications. As a particle detector, this CCD will have unprecedented sensitivity to low-mass dark matter particles and coherent neutrino-nucleus scattering, while astronomical applications include future direct imaging and spectroscopy of exoplanets.

  20. Effect of electron contamination on scatter correction factors for photon beam dosimetry.

    Science.gov (United States)

    Venselaar, J; Heukelom, S; Jager, N; Mijnheer, B; van der Laarse, R; van Gasteren, H; van Kleffens, H; Westermann, C

    1999-10-01

    Physical quantities for use in megavoltage photon beam dose calculations which are defined at the depth of maximum absorbed dose are sensitive to electron contamination and are difficult to measure and to calculate. Recently, formalisms have therefore been presented to assess the dose using collimator and phantom scatter correction factors, Sc and Sp, defined at a reference depth of 10 cm. The data can be obtained from measurements at that depth in a miniphantom and in a full scatter phantom. Equations are presented that show the relation between these quantities and corresponding quantities obtained from measurements at the depth of the dose maximum. It is shown that conversion of Sc and Sp determined at a 10 cm depth to quantities defined at the dose maximum such as (normalized) peak scatter factor, (normalized) tissue-air ratio, and vice versa is not possible without quantitative knowledge of the electron contamination. The difference in Sc at dmax resulting from this electron contamination compared with Sc values obtained at a depth of 10 cm in a miniphantom has been determined as a multiplication factor, Scel, for a number of photon beams of different accelerator types. It is shown that Scel may vary up to 5%. Because in the new formalisms output factors are defined at a reference depth of 10 cm, they do not require Scel data. The use of Sc and Sp values, defined at a 10 cm depth, combined with relative depth-dose data or tissue-phantom ratios is therefore recommended. For a transition period the use of the equations provided in this article and Scel data might be required, for instance, if treatment planning systems apply Sc data normalized at d(max).