  1. Remote Afterloading High Dose Rate Brachytherapy AMC EXPERIANCES

    Energy Technology Data Exchange (ETDEWEB)

    Park, Su Gyong; Chang, Hye Sook; Choi, Eun Kyong; Yi, Byong Yong [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    1992-12-15

    Remote afterloading high dose rate brachytherapy(HDRB) is a new technology and needs new biological principle for time and dose schedule. Here, authors attempt to evaluate the technique and clinical outcome in 116 patients, 590 procedures performed at Asan Medical Center for 3 years. From Sep. 1985 to Aug 1992, 471 procedures of intracavitary radiation in 55 patients of cervical cancer and 26 of nasopharyngeal cancer, 79 intraluminal radiation in 12 of esophageal cancer, 11 of endobronchial cancer and 1 Klatskin tumor and 40 interstitial brachytherapy in 4 of breast cancer, 1 sarcoma and 1 urethral cancer were performed. Median follow-up was 7 months with range 1-31 months. All procedures except interstitial were performed under the local anesthesia and they were all well tolerated and completed the planned therapy except 6 patients. 53/58 patients with cervical cancer and 22/26 patients with nasopharynx cancer achieved CR. Among 15 patients with palliative therapy, 80% achieves palliation. We will describe the details of the technique and results in the text. To evaluate biologic effects of HDRB and optimal time/dose/fractionation schedule, we need longer follow-up. But authors feel that HDRB with proper fractionation schedule may yield superior results compared to the low dose rate brachytherapy considering the advantages of HDRB in safety factor for operator, better control of radiation dose and volume and patients comfort over the low dose brachytherapy.

  2. Physical characteristics of the Selectron high dose rate intracavitary afterloader

    Energy Technology Data Exchange (ETDEWEB)

    Chenery, S.G.A.; Pla, M.; Podgorsak, E.B. (Royal Victoria Hospital, Montreal, Quebec (Canada); McGill Univ., Montreal, Quebec (Canada))

    1985-08-01

    The physics measurements on a Selectron high dose-rate afterloading cobalt-60 unit are reported. The installation was found to be acceptable from the standpoint of radiation safety and cost effectiveness; hospital bed space was saved as treatment could be on an outpatient basis. A source calibration 4% higher than the value stated by the manufacturer was obtained. Measurement of the ratio of exposure rate in water to that in air confirmed the calibration and the applicability of correction factors for routine clinical dosimetry recommended in the literature.

  3. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  4. A method for verification of treatment times for high-dose-rate intraluminal brachytherapy treatment

    Directory of Open Access Journals (Sweden)

    Muhammad Asghar Gadhi

    2016-06-01

    Full Text Available Purpose: This study was aimed to increase the quality of high dose rate (HDR intraluminal brachytherapy treatment. For this purpose, an easy, fast and accurate patient-specific quality assurance (QA tool has been developed. This tool has been implemented at Bahawalpur Institute of Nuclear Medicine and Oncology (BINO, Bahawalpur, Pakistan.Methods: ABACUS 3.1 Treatment planning system (TPS has been used for treatment planning and calculation of total dwell time and then results were compared with the time calculated using the proposed method. This method has been used to verify the total dwell time for different rectum applicators for relevant treatment lengths (2-7 cm and depths (1.5-2.5 cm, different oesophagus applicators of relevant treatment lengths (6-10 cm and depths (0.9 & 1.0 cm, and a bronchus applicator for relevant treatment lengths (4-7.5 cm and depth (0.5 cm.Results: The average percentage differences between treatment time TM with manual calculation and as calculated by the TPS is 0.32% (standard deviation 1.32% for rectum, 0.24% (standard deviation 2.36% for oesophagus and 1.96% (standard deviation 0.55% for bronchus, respectively. These results advocate that the proposed method is valuable for independent verification of patient-specific treatment planning QA.Conclusion: The technique illustrated in the current study is an easy, simple, quick and useful for independent verification of the total dwell time for HDR intraluminal brachytherapy. Our method is able to identify human error-related planning mistakes and to evaluate the quality of treatment planning. It enhances the quality of brachytherapy treatment and reliability of the system.

  5. High-Dose-Rate intraluminal brachytherapy for biliary obstruction by secondary malignant biliary tumors

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Won Sup; Kim, Tae Hyun; Yang, Dae Sik; Choi, Myung Sun; Kim, Chul Yong [College of Medicine, Korea Univ., Seoul (Korea, Republic of)

    2003-03-01

    To analyze the survival period, prognostic factors and complications of patients having under gone high-dose-rate intraluminal brachytherapy (HDR-ILB) as a salvage radiation therapy, while having a catheter, for percutaneous transhepatic biliary drainage (PTBD), inserted due to biliary obstruction caused by a secondary malignant biliary tumor. A retrospective study was performed on 24 patients having undergone HDR-ILB, with PTBD catheter insertion, between December 1992 and August 2001, Their median age was 58.5, ranging from 35 to 82 years. The primary cancer site were the stomach, gallbladder, liver, pancreas and the colon, with 12, 6, 3, 2 and 1 cases, respectively. Eighteen patients were treated with external beam radiation therapy and HDR-ILB, while six were treated with HDR-ILB only. The total external beam, and brachytherapy radiations dose were 30-61.2 and 9-30 Gy, with median doses of 50 and 15 Gy, respectively. Of the 24 patients analyzed, 22 died during the follow-up period, with a median survival of 7.3 months. The 6 and 12 months survival rates were 54.2 (13 patients) and 20.8% (5 patients), respectively. The median survivals for stomach and gallbladder cancers were 7.8 and 10.2 months, respectively. According to the univariate analysis, a significant factor affecting survival of over one year was the total radiation dose (over 50 Gy) (0=0.0200), with all the patients surviving more than one year had been irradiated with more than 50 Gy. The acute side effects during the radiation therapy were managed with conservative treatment. During the follow-up period, 5 patients showed symptoms of cholangitis due to the radiation therapy. An extension to the survival of those patients treated with HDR-ILB is suggested compared to the median historical survival of those patients treated with external biliary drainage. A boost radiation dose could be effectively given, by performing HDR-ILB, which is a prognostic factor. In addition, the acute complications of

  6. Clinical experience of high dose rate brachytherapy using Ir-192 remote afterloading system (microSELECTRON-HDR)

    Energy Technology Data Exchange (ETDEWEB)

    Fukui, Akira; Yamamoto, Koji; Yoshioka, Shinji [Uwajima City Hospital, Ehime (Japan); Kataoka, Masaaki; Fujii, Takashi; Ikezoe, Junpei

    1999-03-01

    Twenty-one lesions were reviewed of 20 patients who were treated with high-dose-rate brachytherapy using Ir-192 remote afterloading system (microSELECTRON-HDR) between August, 1997 and August, 1998. Esophageal cancer (n=6), lung cancer (n=3), cholangioma (n=3), epipharyngeal cancer (n=2) and uterine cervical cancer (n=2) were treated with intracavitary irradiation. Regional skin recurrence of breast cancer (n=3) was treated with interstitial irradiation, and oral cavity cancer (n=2) was treated with the mold method. Eleven lesions were controlled locally with a short follow-up period. There was no significant complication related to the insertion procedures of the applicator or the tubes without pneumothorax in one patient with lung cancer. So far, this treatment is relatively safe and effective not only for curative therapy for early stage cancer but also for palliative therapy for the advanced cancer. Furthermore, it is very important that medical staffs are kept free from radiation exposure. There is no established treatment protocol in high-dose-rate brachytherapy, therefore, a careful longer follow-up is necessary to clarify the true tumor control rate and the development of the late effect on normal tissue. (author)

  7. High-dose-rate intraluminal brachytherapy for paraneoplastic autoimmune multiorgan syndrome.

    Science.gov (United States)

    Lee, Sun-Young; Kim, Jong-Hyun; Cho, Dong-Hyu

    2016-09-01

    Paraneoplastic autoimmune multiorgan syndrome (PAMS), also known as paraneoplasic pemphigus, involves the skin, internal organs and mucosa. PAMS-associated mortality may occur as a result of autoantibody formation against internal tumors and their infiltration into organs other than the skin lesions that characterize PAMS. The most common symptoms of PAMS include pain associated with continuous oral ulceration and resistance to pharmacological treatment. The present study reports the case of a 42-year-old female patient who was admitted with an 8-month history of erosive skin lesions within the trunk region, oral mucosa and vaginal mucosa. The patient was diagnosed with PAMS based on computed tomography scans and histological analyses of the lesions. The lymphoid hyperplasia in the retroperitoneum and lesions in the vaginal mucosa and trunk area were improved following pharmacological treatment and resection of the lymph node showing hyperplasia. However, the oral lesion was treated with intraluminal brachytherapy due to its resistance to long-term pharmacological treatment. The majority of the lesions were improved following treatment, in the absence of any severe side effects. In addition, neither worsening nor progression of the oral lesion was observed during the 4-year follow-up period.

  8. Preoperative radiotherapy for advanced lower rectal cancer. Combination of external and high-dose-rate intraluminal irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Horikawa, Noriko; Yoshimura, Hitoshi; Tamamoto, Tetsuro; Tsuji, Yoshihiko; Uto, Fumiaki; Ohishi, Hajime; Uchida, Hideo; Fujii, Hisao; Nakano, Hiroshige [Nara Medical Univ., Kashihara (Japan)

    1999-01-01

    This paper reports the therapeutic results of preoperative irradiation using a combination of external irradiation and high dose rate intraluminal irradiation using {sup 60}Co aimed at enhancing postoperative local control of advanced rectal cancer. The subjects comprised 38 patients (RT group) in whom {>=} A{sub 1}` lower rectal cancer was suspected and who underwent preoperative irradiation at this hospital. A control group (N-RT group) consisted of 16 patients subjected to operation alone in whom clinical {>=} A{sub 1}` and postoperative histological study revealed {>=} a{sub 1}. Intraluminal irradiation was performed using a balloon applicator. The external irradiation was performed with a 10 MVX delivering 30-40 Gy/15-20 Fr to the entire pelvic cavity. Using the criteria of Ohboshi and Shimozato to judge the histopathological effect, no cases showed Grade I, while of Grade II, 15 cases showed IIA and 19 cases IIB, Grade III in 4 cases. Grade IIB or above was noted in 23 of 38 (61%). Five and 8-year survival rates were 82.5 and 82.5% in the RT group, and were 79.5 and 79.5% in the N-RT group. Although these differences were not significant, a trend to better survival was found in the RT group. The local recurrence rate was 8% (3/38 cases) in the RT group in contrast to 25% (4/16 cases) in the N-RT group. The following complications developed during radiation therapy: diarrhea 19 (50%), anal pain 18 (47%), and others. Postoperative complications consisted of perineal fluid collection 4 (10%), bowel obstruction 3 cases (8%), an anastomotic insufficiency 3 (8%), fistula formation of bladder 2 (5%), ureteral narrowing 1 (3%), and thrombosis of vein 1 cases (3%) of the RT group, while perineal fluid collection 1 (6%), bowel obstruction 1 (6%), an anastomotic insufficiency 4 (25%) of the N-RT group, only one case of RT group (3%) required surgical treatment for the fistula formation of bladder. (K.H.)

  9. High-dose-rate intraluminal brachytherapy prior to external radiochemotherapy in locally advanced esophageal cancer: preliminary results.

    Science.gov (United States)

    Safaei, Afsaneh Maddah; Ghalehtaki, Reza; Khanjani, Nezhat; Farazmand, Borna; Babaei, Mohammad; Esmati, Ebrahim

    2017-02-01

    Dysphagia is a common initial presentation in locally advanced esophageal cancer and negatively impacts patient quality of life and treatment compliance. To induce fast relief of dysphagia in patients with potentially operable esophageal cancer high-dose-rate (HDR) brachytherapy was applied prior to definitive radiochemotherapy. In this single arm phase II clinical trial between 2013 to 2014 twenty patients with locally advanced esophageal cancer (17 squamous cell and 3 adenocarcinoma) were treated with upfront 10 Gy HDR brachytherapy, followed by 50.4 Gy external beam radiotherapy (EBRT) and concurrent chemotherapy with cisplatin/5-fluorouracil. Tumor response, as measured by endoscopy and/or computed tomography scan, revealed complete remission in 16 and partial response in 4 patients (overall response rate 100%). Improvement of dysphagia was induced by brachytherapy within a few days and maintained up to the end of treatment in 80% of patients. No differences in either response rate or dysphagia resolution were found between squamous cell and adenocarcinoma histology. The grade 2 and 3 acute pancytopenia or bicytopenia reported in 4 patients, while sub-acute adverse effects with painful ulceration was seen in five patients, occurring after a median of 2 months. A perforation developed in one patient during the procedure of brachytherapy that resolved successfully with immediate surgery. Brachytherapy before EBRT was a safe and effective procedure to induce rapid and durable relief from dysphagia, especially when combined with EBRT.

  10. Shielding evaluation of a medical linear accelerator vault in preparation for installing a high-dose rate 252Cf remote afterloader.

    Science.gov (United States)

    Melhus, C S; Rivard, M J; Kurkomelis, J; Liddle, C B; Massé, F X

    2005-01-01

    In support of the effort to begin high-dose rate 252Cf brachytherapy treatments at Tufts-New England Medical Center, the shielding capabilities of a clinical accelerator vault against the neutron and photon emissions from a 1.124 mg 252Cf source were examined. Outside the clinical accelerator vault, the fast neutron dose equivalent rate was below the lower limit of detection of a CR-39 etched track detector and below 0.14 +/- 0.02 muSv h(-1) with a proportional counter, which is consistent, within the uncertainties, with natural background. The photon dose equivalent rate was also measured to be below background levels (0.1 muSv h(-1)) using an ionisation chamber and an optically stimulated luminescence dosemeter. A Monte Carlo simulation of neutron transport through the accelerator vault was performed to validate measured values and determine the thermal-energy to low-energy neutron component. Monte Carlo results showed that the dose equivalent rate from fast neutrons was reduced by a factor of 100,000 after attenuation through the vault wall, and the thermal-energy neutron dose equivalent rate would be an additional factor of 1000 below that of the fast neutrons. Based on these findings, the shielding installed in this facility is sufficient for the use of at least 5.0 mg of 252Cf.

  11. [Hopes of high dose-rate radiotherapy].

    Science.gov (United States)

    Fouillade, Charles; Favaudon, Vincent; Vozenin, Marie-Catherine; Romeo, Paul-Henri; Bourhis, Jean; Verrelle, Pierre; Devauchelle, Patrick; Patriarca, Annalisa; Heinrich, Sophie; Mazal, Alejandro; Dutreix, Marie

    2017-04-01

    In this review, we present the synthesis of the newly acquired knowledge concerning high dose-rate irradiations and the hopes that these new radiotherapy modalities give rise to. The results were presented at a recent symposium on the subject. Copyright © 2017. Published by Elsevier Masson SAS.

  12. Experiences of high dose rate interstitial brachytherapy for carcinoma of the mobile tongue

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Hiroshi; Inoue, Toshihiko; Yamazaki, Hideya (Osaka Univ. (Japan). Faculty of Medicine) (and others)

    1994-03-01

    Interstitial brachytherapy was conducted for mobile tongue carcinoma using a high dose rate remote afterloading machine with small [sup 192]I source. Detailed method, named as 'linked double-botton technique', is to approach from submandibular skin by an open-ended stainless steel needles to the tongue lesion, and to replace each needle into flexible nylon tube from the oral cavity. Delivered dose was 60 Gy/10 Fr./5-6 days at the distance 5 mm from the source plane. Ten patients with mobile tongue carcinoma Tl-2N0 were treated with this method from October 1991 through August 1992. Local was uncontrolled in one patient, in whom the lesion was combined with leukoplakia at both lateral borders of the tongue. This was in accordance with the result in low dose rate treatment. This can be a substitute to low dose rate system for treatment of mobile tongue carcinoma. (author).

  13. SU-E-T-242: Design of a Novel Afterloader Clearance QA Device for Biliary HDR Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Mullins, JP; Deufel, CL [Mayo Clinic, Rochester, MN (United States)

    2015-06-15

    Purpose: Bile duct cancer affects 2–3 thousand people annually in the United States. Radiation therapy has been shown to double median survival, with combined external beam and intraluminal high dose-rate (HDR) brachytherapy being most effective. Endoscopic retrograde cholangiopancreatography (ERCP) biliary HDR, a less-invasive alternative to trans-hepatic brachytherapy, is delivered through a catheter that travels a tortuous path from nose to bile duct, requiring wire drive force and dexterity beyond typical afterloader performance specifications. Thus, specific afterloader quality assurance(QA) is recommended for this procedure. Our aim was to create a device and process for Varisource afterloader clearance QA with objectives that it be quantitative and can monitor afterloader performance over time, compare performance between two distinct afterloaders and potentially Result in a predictive nomogram for patient-specific clearance. Methods: Based on retrospective reconstruction of 20 ERCP patient anatomies, we designed a phantom to test afterloader ability to drive the source wire along an intended treatment path. The ability of the afterloader to fully extend the intended treatment path is a function of number and diameters of turns. We have determined experimentally that relative position of the turns does not impact performance. Results: Both patient and QA paths involve three common turns/loops: a large turn representing the stomach(10.8cm±2.0cm), an elliptical loop representing the duodenum(7.3cm±1.5cmx4.8cm±0.7cm), and a final turn at the end of the bile duct that may be tight for some patient-specific anatomies and absent in others(3.7cm±0.7cm, where present). Our phantom design uses anatomical average turn diameters for the stomach and duodenum then terminates in a turn of quantitatively selectable diameter. The smallest final turn diameter that an afterloader can pass is recorded as the QA parameter. Conclusion: With this device and QA process, we

  14. The transit dose component of high dose rate brachytherapy: Direct measurements and clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Bastin, K.T.; Podgorsak, M.B.; Thomadsen, B.R. (Univ. of Wisconsin Hospitals and Clinics, Madison, WI (United States))

    1993-07-15

    The purpose was to measure the transit dose produced by a moving high dose rate brachytherapy source and assess its clinical significance. The doses produced from source movement during Ir-192 HDR afterloading were measured using calibrated thermoluminescent dosimeter rods. Transit doses at distances of 0.5-4.0 cm from an endobronchial applicator were measured using a Lucite phantom accommodating 1 x 1 x 6 mm thermoluminescent rods. Surface transit dose measurements were made using esophageal and endobronchial catheters, a gynecologic tandem, and an interstitial needle. No difference was detected in thermoluminescent dosimeter rod responses to 4 MV and Ir-192 spectra (427 nC/Gy) in a range of dose between 2 and 300 cGy. The transit dose at 0.5 cm from an endobronchial catheter was 0.31 cGy/(Curie-fraction) and followed an inverse square fall-off with increasing distance. Surface transit doses ranged from 0.38 cGy/(Curie-fraction) for an esophageal catheter to 1.03 cGy/(Curie-fraction) for an endobronchial catheter. Source velocity is dependent on the interdwell distance and varies between 220-452 mm/sec. A numeric algorithm was developed to calculate total transit dose, and was based on a dynamic point approximation for the moving high dose rate source. This algorithm reliably predicted the empirical transit doses and demonstrated that total transit dose is dependent on source velocity, number of fractions, and source activity. Surface transit doses are dependent on applicator diameter and wall material and thickness. Total transit doses within or outside the desired treatment volume are typically <100 cGy, but may exceed 200 cGy when using a large number of fractions with a high activity source. 9 refs., 8 figs., 1 tab.

  15. Clinical outcome of high-dose-rate interstitial brachytherapy in patients with oral cavity cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sung Uk; Cho, Kwan Ho; Moon, Sung Ho; Choi, Sung Weon; Park, Joo Yong; Yun, Tak; Lee, Sang Hyun; Lim, Young Kyung; Jeong, Chi Young [National Cancer Center, Goyang (Korea, Republic of)

    2014-12-15

    To evaluate the clinical outcome of high-dose-rate (HDR) interstitial brachytherapy (IBT) in patients with oral cavity cancer. Sixteen patients with oral cavity cancer treated with HDR remote-control afterloading brachytherapy using 192Ir between 2001 and 2013 were analyzed retrospectively. Brachytherapy was administered in 11 patients as the primary treatment and in five patients as salvage treatment for recurrence after the initial surgery. In 12 patients, external beam radiotherapy (50-55 Gy/25 fractions) was combined with IBT of 21 Gy/7 fractions. In addition, IBT was administered as the sole treatment in three patients with a total dose of 50 Gy/10 fractions and as postoperative adjuvant treatment in one patient with a total of 35 Gy/7 fractions. The 5-year overall survival of the entire group was 70%. The actuarial local control rate after 3 years was 84%. All five recurrent cases after initial surgery were successfully salvaged using IBT +/- external beam radiotherapy. Two patients developed local recurrence at 3 and 5 months, respectively, after IBT. The acute complications were acceptable (< or =grade 2). Three patients developed major late complications, such as radio-osteonecrosis, in which one patient was treated by conservative therapy and two required surgical intervention. HDR IBT for oral cavity cancer was effective and acceptable in diverse clinical settings, such as in the cases of primary or salvage treatment.

  16. Radiation Parameters of High Dose Rate Iridium -192 Sources

    Science.gov (United States)

    Podgorsak, Matthew B.

    A lack of physical data for high dose rate (HDR) Ir-192 sources has necessitated the use of basic radiation parameters measured with low dose rate (LDR) Ir-192 seeds and ribbons in HDR dosimetry calculations. A rigorous examination of the radiation parameters of several HDR Ir-192 sources has shown that this extension of physical data from LDR to HDR Ir-192 may be inaccurate. Uncertainty in any of the basic radiation parameters used in dosimetry calculations compromises the accuracy of the calculated dose distribution and the subsequent dose delivery. Dose errors of up to 0.3%, 6%, and 2% can result from the use of currently accepted values for the half-life, exposure rate constant, and dose buildup effect, respectively. Since an accuracy of 5% in the delivered dose is essential to prevent severe complications or tumor regrowth, the use of basic physical constants with uncertainties approaching 6% is unacceptable. A systematic evaluation of the pertinent radiation parameters contributes to a reduction in the overall uncertainty in HDR Ir-192 dose delivery. Moreover, the results of the studies described in this thesis contribute significantly to the establishment of standardized numerical values to be used in HDR Ir-192 dosimetry calculations.

  17. Image-guided high dose rate endorectal brachytherapy.

    Science.gov (United States)

    Devic, Slobodan; Vuong, Té; Moftah, Belal; Evans, Michael; Podgorsak, Ervin B; Poon, Emily; Verhaegen, Frank

    2007-11-01

    Fractionated high dose rate endorectal brachytherapy (HDR-EBT) using CT-based treatment planning is an alternative method for preoperative down-sizing and down-staging of advanced rectal adeno-carcinomas. The authors present an image guidance procedure that was developed to ensure daily dose reproducibility for the four brachytherapy treatment fractions. Since the applicator might not be placed before each treatment fraction inside the rectal lumen in the same manner as it was placed during the 3D CT volume acquisition used for treatment planning, there is a shift along the catheter axis that may have to be performed. The required shift is determined by comparison of a daily radiograph with the treatment planning digitally-reconstructed radiograph (DRR). A procedure is developed for DRR reconstruction from the 3D data set used for the treatment planning, and two possible daily longitudinal shifts are illustrated: above and below the planning dose distribution. The authors also describe the procedure for rotational alignment illustrated on a clinical case. Reproduction of the treatment planned dose distribution on a daily basis is crucial for the success of fractionated 3D based brachytherapy treatments. Due to the cylindrical symmetry of the applicator used for preoperative HDR-EBT, two types of adjustments are necessary: applicator rotation and dwell position shift along the applicator's longitudinal axis. The impact of the longitudinal applicator shift prior to treatment delivery for 62 patients treated in our institution is also assessed.

  18. Implementation of a High-Dose-Rate Brachytherapy Program for Carcinoma of the Cervix in Senegal: A Pragmatic Model for the Developing World

    Energy Technology Data Exchange (ETDEWEB)

    Einck, John P., E-mail: jeinck@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California (United States); Hudson, Alana [Department of Oncology, Tom Baker Cancer Centre, University of Calgary, Calgary, Alberta (Canada); Shulman, Adam C. [Overlook Medical Center, Summit, New Jersey (United States); Yashar, Catheryn M. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California (United States); Dieng, Mamadou M.; Diagne, Magatte; Gueye, Latifatou; Gningue, Fama; Gaye, Pape M. [Départemént de Radiothérapie, Institut Joliot-Curie, Hôpital Aristide Le Dantec, Dakar (Senegal); Fisher, Brandon J. [GammaWest Cancer Services, Salt Lake City, Utah (United States); Mundt, Arno J. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California (United States); Brown, Derek W. [Department of Oncology, Tom Baker Cancer Centre, University of Calgary, Calgary, Alberta (Canada)

    2014-07-01

    West Africa has one of the highest incidence rates of carcinoma of the cervix in the world. The vast majority of women do not have access to screening or disease treatment, leading to presentation at advanced stages and to high mortality rates. Compounding this problem is the lack of radiation treatment facilities in Senegal and many other parts of the African continent. Senegal, a country of 13 million people, had a single {sup 60}Co teletherapy unit before our involvement and no brachytherapy capabilities. Radiating Hope, a nonprofit organization whose mission is to provide radiation therapy equipment to countries in the developing world, provided a high-dose-rate afterloading unit to the cancer center for curative cervical cancer treatment. Here we describe the implementation of high-dose-rate brachytherapy in Senegal requiring a nonstandard fractionation schedule and a novel treatment planning approach as a possible blueprint to providing this technology to other developing countries.

  19. Implementation of a high-dose-rate brachytherapy program for carcinoma of the cervix in Senegal: a pragmatic model for the developing world.

    Science.gov (United States)

    Einck, John P; Hudson, Alana; Shulman, Adam C; Yashar, Catheryn M; Dieng, Mamadou M; Diagne, Magatte; Gueye, Latifatou; Gningue, Fama; Gaye, Pape M; Fisher, Brandon J; Mundt, Arno J; Brown, Derek W

    2014-07-01

    West Africa has one of the highest incidence rates of carcinoma of the cervix in the world. The vast majority of women do not have access to screening or disease treatment, leading to presentation at advanced stages and to high mortality rates. Compounding this problem is the lack of radiation treatment facilities in Senegal and many other parts of the African continent. Senegal, a country of 13 million people, had a single (60)Co teletherapy unit before our involvement and no brachytherapy capabilities. Radiating Hope, a nonprofit organization whose mission is to provide radiation therapy equipment to countries in the developing world, provided a high-dose-rate afterloading unit to the cancer center for curative cervical cancer treatment. Here we describe the implementation of high-dose-rate brachytherapy in Senegal requiring a nonstandard fractionation schedule and a novel treatment planning approach as a possible blueprint to providing this technology to other developing countries.

  20. Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy.

    Directory of Open Access Journals (Sweden)

    Luciana Tourinho Campos

    Full Text Available The use of high-dose-rate brachytherapy is currently a widespread practice worldwide. The most common isotope source is 192Ir, but 60Co is also becoming available for HDR. One of main advantages of 60Co compared to 192Ir is the economic and practical benefit because of its longer half-live, which is 5.27 years. Recently, Eckert & Ziegler BEBIG, Germany, introduced a new afterloading brachytherapy machine (MultiSource®; it has the option to use either the 60Co or 192Ir HDR source. The source for the Monte Carlo calculations is the new 60Co source (model Co0.A86, which is referred to as the new BEBIG 60Co HDR source and is a modified version of the 60Co source (model GK60M21, which is also from BEBIG.The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy to investigate the required treatment-planning parameters. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. To validate the source geometry, a few dosimetry parameters had to be calculated according to the AAPM TG-43U1 formalism. The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The spectrum to simulate 60Co was composed of two photon energies, 1.17 and 1.33 MeV. Only the gamma part of the spectrum was used; the contribution of the electrons to the dose is negligible because of the full absorption by the stainless-steel wall around the metallic 60Co. The XCOM photon cross-section library was used in subsequent simulations, and the photoelectric effect, pair

  1. Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy

    Science.gov (United States)

    Campos, Luciana Tourinho; de Almeida, Carlos Eduardo Veloso

    2015-01-01

    Introduction The use of high-dose-rate brachytherapy is currently a widespread practice worldwide. The most common isotope source is 192Ir, but 60Co is also becoming available for HDR. One of main advantages of 60Co compared to 192Ir is the economic and practical benefit because of its longer half-live, which is 5.27 years. Recently, Eckert & Ziegler BEBIG, Germany, introduced a new afterloading brachytherapy machine (MultiSource®); it has the option to use either the 60Co or 192Ir HDR source. The source for the Monte Carlo calculations is the new 60Co source (model Co0.A86), which is referred to as the new BEBIG 60Co HDR source and is a modified version of the 60Co source (model GK60M21), which is also from BEBIG. Objective and Methods The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy to investigate the required treatment-planning parameters. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. To validate the source geometry, a few dosimetry parameters had to be calculated according to the AAPM TG-43U1 formalism. The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The spectrum to simulate 60Co was composed of two photon energies, 1.17 and 1.33 MeV. Only the gamma part of the spectrum was used; the contribution of the electrons to the dose is negligible because of the full absorption by the stainless-steel wall around the metallic 60Co. The XCOM photon cross-section library was used in subsequent simulations, and the

  2. A case of percutaneous high dose rate brachytherapy for superior pulmonary sulcus tumor

    Energy Technology Data Exchange (ETDEWEB)

    Asakura, Tamaki; Imamura, Masahiro; Murata, Takashi [Kansai Medical Univ., Moriguchi, Osaka (Japan)] [and others

    1996-07-01

    A 64-year-old man with advanced superior pulmonary sulcus tumor suffered severe unrelieved pain even after chemotherapy, external irradiation and hyperthermia. So we planned to introduce a percutaneous high dose rate brachytherapy using the microselectron HDR {sup 192}Ir. With the estimation using the Pain Score, satisfying pain relief was attainable with a combination of the percutaneous high dose rate brachytherapy and conventional treatment. So the percutaneous high dose rate brachytherapy had the possibility to contribute to the alleviation of the pain. (author)

  3. Intraluminal Gossypiboma

    Directory of Open Access Journals (Sweden)

    Yousuf Aziz Khan

    2014-05-01

    Full Text Available Gossypiboma (GP or retained surgical sponge is one of the rare surgical complications which can happen despite precautions. Because of the medico-legal issues, it is under-reported. An 8-year-old thalassemic girl, with a history of splenectomy and cholecystectomy, presented to us with acute intestinal obstruction and required surgical exploration. Intraluminal gossypiboma obstructing the ileum was found. Though a rare cause, gossypiboma should also be included in the differential diagnoses of postoperative intestinal obstruction.

  4. Modulation of toxicity following external beam irradiation preceded by high-dose rate brachytherapy in inoperable oesophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Taal, B.G.; Aleman, B.M.P.; Koning, C.C.E.; Boot, H. [Nederlands Kanker Inst. `Antoni van Leeuwenhoekhuis`, Amsterdam (Netherlands)

    1996-09-01

    To induce fast relief of dysphagia in inoperable oesephageal cancer, we applied high-dose rate (HDR) intraluminal irradiation followed by external irradiation (EBRT) in a phase II study. 15 patients (group A: n = 15; 10 men, 5 women; median age 66 years) were treated with 10 Gy HDR brachytherapy plus 40 Gy EBRT (15 fractions of 2.67 Gy). Severe side-effects were encountered in 60% of patients: 3 late ulceration, 2 pending fistula and 2 patients with fatal haemorrhage after an interval of 6 months. Overall response was excellent: 9 complete remissions (60%) and 6 partial responses (40%). Because of the high toxicity rate, in a subsequent study (group B: n = 30; 23 mean, 7 women; median age 66 years) the EBRT scheme was changed using smaller fractions (2.0 Gy) to reach the same total dose of 40 Gy. The complication rate (17%) was significantly reduced, while the overall response remained excellent (83%): 17 complete and 8 partial responses. The impressive change in complication rate of HDR brachytherapy and EBRT stresses the impact of the fraction per dose and illustrates the small therapeutic margins. (author).

  5. ``In Vivo'' Dosimetry in High Dose Rate Brachytherapy for Cervical Cancer Treatments

    Science.gov (United States)

    González-Azcorra, S. A.; Mota-García, A.; Poitevín-Chacón, M. A.; Santamaría-Torruco, B. J.; Rodríguez-Ponce, M.; Herrera-Martínez, F. P.; Gamboa de Buen, I.; Ruíz-Trejo, C.; Buenfil, A. E.

    2008-08-01

    In this prospective study, rectal dose was measured "in vivo" using TLD-100 crystals (3×3×1 mm3), and it has been compared to the prescribed dose. Measurements were performed in patients with cervical cancer classified in FIGO stages IB-IIIB and treated with high dose rate brachytherapy (HDR BT) at the Instituto Nacional de Cancerología (INCan).

  6. Perioperative Interstitial High-Dose-Rate Brachytherapy for the Treatment of Recurrent Keloids

    DEFF Research Database (Denmark)

    Jiang, Ping; Baumann, René; Dunst, Juergen;

    2016-01-01

    PURPOSE: To prospectively evaluate high-dose-rate brachytherapy in the treatment of therapy-resistant keloids and report first results, with emphasis on feasibility and early treatment outcome. METHODS AND MATERIALS: From 2009 to 2014, 24 patients with 32 recurrent keloids were treated with immed...

  7. An automated optimization tool for high-dose-rate (HDR) prostate brachytherapy with divergent needle pattern

    NARCIS (Netherlands)

    Borot, Maxence; Maenhout, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; van Vulpen, M.; Moerland, M. A.

    2015-01-01

    Focal high-dose-rate (HDR) for prostate cancer has gained increasing interest as an alternative to whole gland therapy as it may contribute to the reduction of treatment related toxicity. For focal treatment, optimal needle guidance and placement is warranted. This can be achieved under MR guidance.

  8. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, Antonio Cassio Assis, E-mail: acapellizzon@hcancer.org.br [A.C. Camargo Cancer Center, Sao Paulo, SP (Brazil). Departamento de Radioterapia

    2016-05-15

    For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy. (author)

  9. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer*

    Science.gov (United States)

    Pellizzon, Antônio Cássio Assis

    2016-01-01

    For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy. PMID:27403021

  10. Monitoring performance of the cameras under the high dose-rate gamma ray environments.

    Science.gov (United States)

    Cho, Jai Wan; Choi, Young Soo; Jeong, Kyung Min

    2014-05-01

    CCD/CMOS cameras, loaded on a robot system, are generally used as the eye of the robot and monitoring unit. A major problem that arises when dealing with images provided by CCD/CMOS cameras under severe accident situations of a nuclear power plant is the presence of speckles owing to the high dose-rate gamma irradiation fields. To use a CCD/CMOS camera as a monitoring unit in a high radiation area, the legibility of the camera image in such intense gamma-radiation fields should therefore be defined. In this paper, the authors describe the monitoring index as a figure of merit of the camera's legibleness under a high dose-rate gamma ray irradiation environment. From a low dose-rate (10 Gy h) to a high dose-rate (200 Gy h) level, the legible performances of the cameras owing to the speckles are evaluated. The numbers of speckles generated by gamma ray irradiation in the camera image are calculated by an image processing technique. The legibility of the sensor indicator (thermo/hygrometer) owing to the number of speckles is also presented.

  11. 3D CT-based high-dose-rate breast brachytherapy implants: treatment planning and quality assurance.

    Science.gov (United States)

    Das, Rupak K; Patel, Rakesh; Shah, Hiral; Odau, Heath; Kuske, Robert R

    2004-07-15

    Although accelerated partial breast irradiation (APBI) as the sole radiation modality after lumpectomy has shown promising results for select breast cancer patients, published experiences thus far have provided limited information on treatment planning methodology and quality assurance measures. A novel three-dimensional computed tomography (CT)-based treatment planning method for accurate delineation and geometric coverage of the target volume is presented. A correlation between treatment volume and irradiation time has also been studied for quality assurance purposes. Between May 2002 and January 2003, 50 consecutive patients underwent an image-guided interstitial implant followed by CT-based treatment planning and were subsequently treated with APBI with a high-dose-rate (HDR) brachytherapy remote afterloader. Target volume was defined as the lumpectomy cavity +2 cm margin modified to >/=5 mm to the skin surface. Catheter reconstruction, geometric optimization, and manual adjustment of irradiation time were done to optimally cover the target volume while minimizing hot spots. Dose homogeneity index (DHI) and percent of target volume receiving 100% of the prescription dose (32 Gy in 8 fractions or 34 Gy in 10 fractions) was determined. Additionally, the correlation between the treatment volume and irradiation time, source strength, and dose was then analyzed for manual verification of the HDR computer calculation. In all cases, the lumpectomy cavity was covered 100%. Target volume coverage was excellent with a median of 96%, and DHI had a median value of 0.7. For each plan, source strength times the treatment time for every unit of prescribed dose had an excellent agreement of +/-7% to the Manchester volume implant table corrected for modern units. CT-based treatment planning allowed excellent visualization of the lumpectomy cavity and normal structures, thereby improving target volume delineation and optimal coverage, relative to conventional orthogonal film

  12. High dose rate brachytherapy using custom made superficial mould applicators and Leipzig applicators for non melanoma localized skin cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, A. Cassio A.; Miziara, Daniela; Lima, Flavia Pedroso de; Miziara, Miguel

    2014-07-01

    Purpose: advances in technology and the commercial production of Leipzig applicators allowed High Dose Rate after-load brachytherapy (HDR-BT) to address a number of the challenges associated with the delivery of superficial radiation to treat localized non melanoma skin cancer (NMSK). We reviewed our uni-institutional experience on the treatment of NMSK with HDR-BT. Methods: data were collected retrospectively from patients attending the Radiation Oncology Department at AV Carvalho Insitute, Sao Paulo, Brazil. HDR-BT was done using the stepping source HDR 192Ir Microselectron (Nucletron BV). The planning target volume consisted of the macroscopic lesion plus a 5mm to 10mm margin.The depth of treatment was 0.5 cm in smaller (< 2.0 cm) tumors and 10 to 15 mm for lesions bigger than that. Results: Thirteen patients were treated with HDR-BT from June, 2007 to June 2013. The median age and follow up time were 72 (38-90) years old and 36 (range, 7-73) months, respectively. There a predominance of males (61.5%) and of patients referred for adjuvant treatment due positive surgical margins or because they have had only a excision biopsy without safety margins (61.5%). Six (46.2%) patients presented with squamous cell carcinoma and 7 (53.8%) patients presented with basal cell carcinoma. The median tumor size was 20 (range, 5-42) mm. Patients were treated with a median total dose of 40 Gy (range, 20 -60), given in 10 (range, 2-15) fractions, given daily or twice a week. All patients responded very well to treatment and only one patient has failed locally so far, after 38 months of the end of the irradiation. The crude and actuarial 3-year local control rates were 100% and 80%, respectively. Moist desquamation, grade 2 RTOG, was observed in 4 (30.8%) patients. Severe late complication, radiation-induced dyspigmentation, occurred in 2 patients and 1 of the patients also showed telangiectasia in the irradiated area. The cosmetic result was considered good in 84% (11/13) patients

  13. Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions

    Energy Technology Data Exchange (ETDEWEB)

    Candela-Juan, C., E-mail: ccanjuan@gmail.com [Radiation Oncology Department, La Fe University and Polytechnic Hospital, Valencia 46026, Spain and National Dosimetry Centre (CND), Valencia 46009 (Spain); Niatsetski, Y. [Elekta Brachytherapy, Veenendaal 3905 TH (Netherlands); Laarse, R. van der [Quality Radiation Therapy BV, Zeist 3707 HB (Netherlands); Granero, D. [Department of Radiation Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Ballester, F. [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Perez-Calatayud, J. [Radiation Oncology Department, La Fe University and Polytechnic Hospital, Valencia 46026, Spain and Department of Radiotherapy, Clínica Benidorm, Benidorm 03501 (Spain); Vijande, J. [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100, Spain and Instituto de Física Corpuscular (UV-CSIC), Burjassot 46100 (Spain)

    2016-04-15

    Purpose: The aims of this study were (i) to design a new high-dose-rate (HDR) brachytherapy applicator for treating surface lesions with planning target volumes larger than 3 cm in diameter and up to 5 cm in size, using the microSelectron-HDR or Flexitron afterloader (Elekta Brachytherapy) with a {sup 192}Ir source; (ii) to calculate by means of the Monte Carlo (MC) method the dose distribution for the new applicator when it is placed against a water phantom; and (iii) to validate experimentally the dose distributions in water. Methods: The PENELOPE2008 MC code was used to optimize dwell positions and dwell times. Next, the dose distribution in a water phantom and the leakage dose distribution around the applicator were calculated. Finally, MC data were validated experimentally for a {sup 192}Ir mHDR-v2 source by measuring (i) dose distributions with radiochromic EBT3 films (ISP); (ii) percentage depth–dose (PDD) curve with the parallel-plate ionization chamber Advanced Markus (PTW); and (iii) absolute dose rate with EBT3 films and the PinPoint T31016 (PTW) ionization chamber. Results: The new applicator is made of tungsten alloy (Densimet) and consists of a set of interchangeable collimators. Three catheters are used to allocate the source at prefixed dwell positions with preset weights to produce a homogenous dose distribution at the typical prescription depth of 3 mm in water. The same plan is used for all available collimators. PDD, absolute dose rate per unit of air kerma strength, and off-axis profiles in a cylindrical water phantom are reported. These data can be used for treatment planning. Leakage around the applicator was also scored. The dose distributions, PDD, and absolute dose rate calculated agree within experimental uncertainties with the doses measured: differences of MC data with chamber measurements are up to 0.8% and with radiochromic films are up to 3.5%. Conclusions: The new applicator and the dosimetric data provided here will be a valuable

  14. Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions.

    Science.gov (United States)

    Candela-Juan, C; Niatsetski, Y; van der Laarse, R; Granero, D; Ballester, F; Perez-Calatayud, J; Vijande, J

    2016-04-01

    The aims of this study were (i) to design a new high-dose-rate (HDR) brachytherapy applicator for treating surface lesions with planning target volumes larger than 3 cm in diameter and up to 5 cm in size, using the microSelectron-HDR or Flexitron afterloader (Elekta Brachytherapy) with a (192)Ir source; (ii) to calculate by means of the Monte Carlo (MC) method the dose distribution for the new applicator when it is placed against a water phantom; and (iii) to validate experimentally the dose distributions in water. The penelope2008 MC code was used to optimize dwell positions and dwell times. Next, the dose distribution in a water phantom and the leakage dose distribution around the applicator were calculated. Finally, MC data were validated experimentally for a (192)Ir mHDR-v2 source by measuring (i) dose distributions with radiochromic EBT3 films (ISP); (ii) percentage depth-dose (PDD) curve with the parallel-plate ionization chamber Advanced Markus (PTW); and (iii) absolute dose rate with EBT3 films and the PinPoint T31016 (PTW) ionization chamber. The new applicator is made of tungsten alloy (Densimet) and consists of a set of interchangeable collimators. Three catheters are used to allocate the source at prefixed dwell positions with preset weights to produce a homogenous dose distribution at the typical prescription depth of 3 mm in water. The same plan is used for all available collimators. PDD, absolute dose rate per unit of air kerma strength, and off-axis profiles in a cylindrical water phantom are reported. These data can be used for treatment planning. Leakage around the applicator was also scored. The dose distributions, PDD, and absolute dose rate calculated agree within experimental uncertainties with the doses measured: differences of MC data with chamber measurements are up to 0.8% and with radiochromic films are up to 3.5%. The new applicator and the dosimetric data provided here will be a valuable tool in clinical practice, making treatment of

  15. High dose rate brachytherapy in early stage squamous-cell carcinoma of the lip.

    Science.gov (United States)

    Mut, Alejandro; Guinot, José Luis; Arribas, Leoncio; Díez-Presa, Lorena; Tortajada, María Isabel; Santos, Miguel Ángel; Samper, Josefa; Santamaría, Paula; Vendrell, Juan Bosco

    2016-01-01

    To analyze the results obtained after treatment of early stage (T1-T2) squamous cell carcinoma of the lip with high dose rate brachytherapy and evaluate the efficacy of this treatment in both local and regional control. Retrospective analysis of the treatments performed at our department from March 1999 to March 2013 with high dose rate brachytherapy with rigid needles. We included 68 patients, 63 men and 5 women; 37 patients (54.4%) presented a T1 tumour, less than or equal to 2cm, while the other 31 (45.6%) were classified as T2. Median total dose was 45Gy, with a median dose per fraction of 5Gy x 9 fractions twice a day for 5 days. With a mean follow-up of 56.4 months, local control was 96.9%. Stratifying by tumour size, local control of T1 cases was 100%, while T2 achieved 93.2% (2 local recurrences). Regional control at 5 years was 93.8% for T1, and 80.8% for T2. In 11 cases with elective cervical treatment, no regional failure happened. As for toxicity, no patient presented soft tissue, or bone, necrosis. All patients achieved good or excellent cosmetic and functional results. High dose rate brachytherapy allows effective, safe treatments for squamous cell carcinoma of the lip, with good aesthetic and functional results. It can be considered a valid alternative for surgery in early stage tumours. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  16. Image-guided high-dose-rate brachytherapy in inoperable endometrial cancer

    Science.gov (United States)

    Petsuksiri, J; Chansilpa, Y; Hoskin, P J

    2014-01-01

    Inoperable endometrial cancer may be treated with curative aim using radical radiotherapy alone. The radiation techniques are external beam radiotherapy (EBRT) alone, EBRT plus brachytherapy and brachytherapy alone. Recently, high-dose-rate brachytherapy has been used instead of low-dose-rate brachytherapy. Image-guided brachytherapy enables sufficient coverage of tumour and reduction of dose to the organs at risk, thus increasing the therapeutic ratio of treatment. Local control rates with three-dimensional brachytherapy appear better than with conventional techniques (about 90–100% and 70–90%, respectively). PMID:24807067

  17. High dose-rate brachytherapy source position quality assurance using radiochromic film.

    Science.gov (United States)

    Evans, M D C; Devic, S; Podgorsak, E B

    2007-01-01

    Traditionally, radiographic film has been used to verify high-dose-rate brachytherapy source position accuracy by co-registering autoradiographic and diagnostic images of the associated applicator. Filmless PACS-based clinics that do not have access to radiographic film and wet developers may have trouble performing this quality assurance test in a simple and practical manner. We describe an alternative method for quality assurance using radiochromic-type film. In addition to being easy and practical to use, radiochromic film has some advantages in comparison with traditional radiographic film when used for HDR brachytherapy quality assurance.

  18. High dose rate endorectal brachytherapy as a neoadjuvant treatment for patients with resectable rectal cancer.

    Science.gov (United States)

    Vuong, T; Devic, S; Podgorsak, E

    2007-11-01

    In the era of total mesorectal surgery, the issue of radiation toxicity is raised. A novel endocavitary brachytherapy technique was tested as a neoadjuvant treatment for patients with resectable rectal cancer. The objectives of the study were to evaluate the treatment-related toxicity and effects on local recurrence. A dose of 26 Gy was prescribed to the gross tumour volume and intramesorectal deposits seen on magnetic resonance imaging and given over four daily treatments, using the high dose rate delivery system followed by surgery 6-8 weeks later. The study included 93 T3, four T4 and three T2 tumours. Acute proctitis of grade 2 was observed in all patients, but one required transfusion. At a median follow-up time of 60 months, the 5-year actual local recurrence rate was 5%, disease-free survival was 65%, and overall survival was 70%. High dose rate endorectal brachytherapy seems to prevent local recurrence and has a favourable toxicity pattern compared with external beam radiotherapy.

  19. Effects of high dose rate gamma radiation on survival and reproduction of Biomphalaria glabrata

    Energy Technology Data Exchange (ETDEWEB)

    Cantinha, Rebeca S.; Nakano, Eliana [Instituto Butantan, Sao Paulo, SP (Brazil). Lab. de Parasitologia], e-mail: rebecanuclear@gmail.com, e-mail: eliananakano@butantan.gov.br; Borrely, Sueli I. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes], e-mail: sborrely@ipen.br; Amaral, Ademir; Melo, Ana M.M.A. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Estudos em Radioprotecao e Radioecologia (GERAR)], e-mail: amaral@ufpe.br; Silva, Luanna R.S. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Biofisica e Radiobiologia. Lab. de Radiobiologia], e-mail: amdemelo@hotmail.com, e-mail: luannaribeiro_lua@hotmail.com

    2009-07-01

    Ionizing radiations are known as mutagenic agents, causing lethality and infertility. This characteristic has motivated its application on animal biological control. In this context, the freshwater snail Biomphalaria glabrata can be considered an excellent experimental model to study effects of ionizing radiations on lethality and reproduction. This work was designed to evaluate effects of {sup 60}Co gamma radiation at high dose rate (10.04 kGy/h) on B. glabrata. For this purpose, adult snails were selected and exposed to doses ranging from 20 to 100 Gy, with 10 Gy intervals; one group was kept as control. There was not effect of dose rate in the lethality of gamma radiation; the value of 64,3 Gy of LD{sub 50} obtained in our study was similar to that obtained by other authors with low dose rates. Nevertheless, our data suggest that there was a dose rate effect in the reproduction. On all dose levels, radiation improved the production of embryos for all exposed individuals. However, viability indexes were below 6% and, even 65 days after irradiation, fertility was not recovered. These results are not in agreement with other studies using low dose rates. Lethality was obtained in all groups irradiated, and the highest doses presented percentiles of dead animals above 50%. The results demonstrated that doses of 20 and 30 Gy were ideal for population control of B. glabrata. Further studies are needed; nevertheless, this research evidenced great potential of high dose rate gamma radiation on B. glabrata reproductive control. (author)

  20. High dose rate endobronchial brachytherapy. Results and complications in 189 patients

    Energy Technology Data Exchange (ETDEWEB)

    Taulelle, M.; Chauvet, B.; Vincent, P.; Felix-Faure, C.; Buciarelli, B.; Garcia, R.; Brewer, Y.; Reboul, F. [Clinique Sainte Catherine, Dept. of Radiation Therapy, Avignon (France)

    1998-02-01

    The purpose of this study was to determine the benefit of high dose rate endobronchial brachytherapy in the treatment of obstructive lung cancer. Between September 1990 and March 1995, 189 patients with bronchogenic carcinoma were treated with high dose rate endobronchial brachytherapy. Most patients (63.3%) had received prior treatment and presented with symptomatic bronchial obstruction due to either recurrent or residual endobronchial disease. A small group (12%) was medically unfit for either surgical resection or thoracic radiotherapy and benefited from endobronchial brachytherapy alone for small endobronchial tumours. The remainder of the patients had not been treated previously and endobronchial brachytherapy was performed for life-threatening symptoms requiring emergency obstruction relief before other therapy. Treatment was performed weekly and consisted of three to four 8 to 10 Gy fractions at a radius of 10 mm from the centre of the source. Major symptomatic relief was obtained for haemoptysis (74%), dyspnoea (54%), and cough (54%). Complete endoscopic response was observed in 54% of cases. Median survival was 7 months for the entire group. For small, strictly endobronchial tumours, complete response rate was 96%, median survival 17 months, and 30 month survival 46%, with a plateau starting at 18 months. Grade 3 to 4 toxicities occurred at a rate of 17% and included massive haemoptysis (n=13), bronchial stenosis (n=12), soft tissue necrosis (n=8), and bronchial fistula (n=3). By univariate analysis, no factor was found to be predictive of late pulmonary toxicity. The present study confirms the usefulness of endobronchial brachytherapy in alleviating symptoms caused by endobronchial recurrence of bronchogenic carcinoma. In addition, this therapy can be tried with curative intent in patients who present with small endobronchial tumours and are not candidates for other forms of therapy. (au). 23 refs.

  1. Chemoradiation in cervical cancer with cisplatin and high-dose rate brachytherapy combined with external beam radiotherapy. Results of a phase-II study

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, H.G.; Laban, C.; Puschmann, D.; Koelbl, H. [Dept. of Gynecology, Martin-Luther Univ. Halle-Wittenberg (Germany); Kuhnt, T.; Pigorsch, S.; Dunst, J.; Haensgen, G. [Dept. of Radiotherapy, Martin-Luther Univ. Halle-Wittenberg (Germany)

    2002-07-01

    chemoradiation with cisplatin 40 mg/m{sup 2} weekly x 6 using HDR brachytherapy represents a promising treatment of cervical cancer with an acceptable toxicity. (orig.) [German] Hintergrund: 1999 zeigten fuenf randomisierte Studien, dass die simultane Radiochemotherapie mit Cisplatin und einer Low-Dose-Rate-Brachytherapie fuer Patientinnen mit einem lokal fortgeschrittenen Zervixkarzinom und in der adjuventen Hochrisikosituation einen Ueberlebensvorteil bringt. Wir untersuchten die Sicherheit und Effektivitaet der simultanen Radiochemotherapie mit Cisplatin und High-Dose-Rate-Brachytherapie bei diesen Patientinnen. Patientinnen und Methode: 27 Patientinnen wurden in unserer Phase-II-Studie eingeschlossen: 13 mit lokal fortgeschrittenen Zervixkarzinomen (Gruppe A) und 14 adjuvante Hochrisikopatientinnen (Gruppe B). Die primaer radiochemotherapierten Faelle erhielten 25 Fraktionen einer perktuanen Hochvolttherapie des Beckens (1,8 Gy pro Fraktion/Einbringen eines Mittelblocks nach elf Fraktionen). Die Brachytherapie wurde bei den FIGO-Stadien IIB-IIIB nach dem High-Dose-Rate-Afterloading-Prinzip mit 7 Gy pro Fraktion in Punkt A (Gesamtdosis 35 Gy) appliziert. Die Gesamtdosis der kombinierten Therapie war 70 Gy in Punkt A und 52-54 Gy in Punkt B. Bei den FIGO-Stadien IVA erfolgte keine Brachyhtherapie. Bei der adjuvanten Strahlentherapie wurde die perkutane Hochvolttherapie des Beckens mit Fraktionen von 1,8 Gy bis zu einer Gesamtdosis von 50,4 Gy appliziert. Die High-Dose-Rate-Afterloading-Brachytherapie mit zwei Fraktionen von 5 Gy erfolgte nur bei Patientinnen, bei denen sich im Operationspraeparat tumorbefallene Resektionsraender oder ein Befall der Scheide fanden. Das Chemotherapieregime mit 6 woechentlichen Gaben von 40 mg/m{sup 2} Cisplatin entsprach dem der Studien 120 und 123 der GOG. Ergebnisse: 18 von 27 Patientinnen (66,7%) erhielten alle sechs Cisplatingaben. Eine Unterbrechung der Strahlentherapie aufgrund von Nebenwirkungen war in keinem Fall erforderlich. Die G3

  2. Dosimetric characterization of the M-15 high-dose-rate Iridium-192 brachytherapy source using the AAPM and ESTRO formalism.

    Science.gov (United States)

    Ho Than, Minh-Tri; Munro Iii, John J; Medich, David C

    2015-05-08

    The Source Production & Equipment Co. (SPEC) model M-15 is a new Iridium-192 brachytherapy source model intended for use as a temporary high-dose-rate (HDR) brachytherapy source for the Nucletron microSelectron Classic afterloading system. The purpose of this study is to characterize this HDR source for clinical application by obtaining a complete set of Monte Carlo calculated dosimetric parameters for the M-15, as recommended by AAPM and ESTRO, for isotopes with average energies greater than 50 keV. This was accomplished by using the MCNP6 Monte Carlo code to simulate the resulting source dosimetry at various points within a pseudoinfinite water phantom. These dosimetric values next were converted into the AAPM and ESTRO dosimetry parameters and the respective statistical uncertainty in each parameter also calculated and presented. The M-15 source was modeled in an MCNP6 Monte Carlo environment using the physical source specifications provided by the manufacturer. Iridium-192 photons were uniformly generated inside the iridium core of the model M-15 with photon and secondary electron transport replicated using photoatomic cross-sectional tables supplied with MCNP6. Simulations were performed for both water and air/vacuum computer models with a total of 4 × 109 sources photon history for each simulation and the in-air photon spectrum filtered to remove low-energy photons belowδ = 10 keV. Dosimetric data, including D·(r,θ), gL(r), F(r,θ), φan(r), and φ-an, and their statistical uncertainty were calculated from the output of an MCNP model consisting of an M-15 source placed at the center of a spherical water phantom of 100 cm diameter. The air kerma strength in free space, SK, and dose rate constant, Λ, also was computed from a MCNP model with M-15 Iridium-192 source, was centered at the origin of an evacuated phantom in which a critical volume containing air at STP was added 100 cm from the source center. The reference dose rate, D·(r0,θ0) ≡ D· (1cm

  3. Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Bhavana [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Patel, Firuza D., E-mail: firuzapatel@gmail.com [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Chakraborty, Santam; Sharma, Suresh C.; Kapoor, Rakesh [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Aprem, Abi Santhosh [Corporate R and D Division, HLL Lifecare Limited, Karamana, Trivandrum (India)

    2013-04-01

    Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the second application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of

  4. Implementation of High-Dose-Rate Brachytherapy and Androgen Deprivation in Patients With Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lilleby, Wolfgang, E-mail: wolfgang.lilleby@ous-hf.no [Cancer Clinic, Oslo University Hospital, Norwegian Radiumhospital, Department of Radiotherapy and Oncology, Oslo (Norway); Tafjord, Gunnar; Raabe, Nils K. [Cancer Clinic, Oslo University Hospital, Norwegian Radiumhospital, Department of Radiotherapy and Oncology, Oslo (Norway)

    2012-07-01

    Purpose: To evaluate outcome (overall survival [OS], the actuarial 5-year cancer-specific survival [CSS], disease-free survival [DFS], biochemical failure-free survival [BFS]), complications and morbidity in patients treated with high-dose-rate brachytherapy (HDR-BT) boost and hormonal treatment with curative aims. Methods: Between 2004 and 2009, 275 prospectively followed pN0/N0M0 patients were included: 19 patients (7%) with T2, Gleason score 7 and prostate-specific antigen (PSA) <10 and 256 patients (93%) with T3 or Gleason score 8-10 or PSA >20 received multimodal treatment with conformal four-field radiotherapy (prostate/vesiculae 2 Gy Multiplication-Sign 25) combined with HDR-BT (iridium 192; prostate 10 Gy Multiplication-Sign 2) with long-term androgen deprivation therapy (ADT). Results: After a median observation time of 44.2 months (range, 10.4-90.5 months) 12 patients had relapsed clinically and/or biochemically and 10 patients were dead, of which 2 patients died from prostate cancer. Five-year estimates of BFS, CSS, DFS, and OS rates were 98.5%, 99.3%, 95.6%, and 96.3%, respectively. None of the patients with either Gleason score <8 or with intermediate risk profile had relapsed. The number of HDR-BT treatments was not related to outcome. Despite of age (median, 65.7 years; range, 45.7-77 years) and considerable pretreatment comorbidity in 39 of 275 patients, Genitourinary treatment-related morbidity was moderate with long-lasting Radiation Therapy Oncology Group Grade 2 voiding problems in 26 patients (9.5%) and occasionally mucous discharge in 20 patients (7%), none with Grade >2 for gastrointestinal at follow-up. Complications during implantations were related to pubic arch interference (4 patients) and lithotomy time, causing 2 patients to develop compartment syndrome. Conclusion: Despite still preliminary observations, our 5-year outcome estimates favor the implementation of high-dose-rate brachytherapy in high-risk patients combined with conformal

  5. Current situation of high-dose-rate brachytherapy for cervical cancer in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rogerio Matias Vidal da; Souza, Divanizia do Nascimento, E-mail: rmv.fisica@gmail.com [Universidade Federal de Sergipe (UFS), Sao Cristovao, SE (Brazil); Pinezi, Juliana Castro Dourado [Pontificia Universidade Catolica de Goias (PUC-Goias), Goiania, GO (Brazil); Macedo, Luiz Eduardo Andrade [Hospital Chama, Arapiraca, AL (Brazil)

    2014-05-15

    To assess the current situation of high-dose-rate (HDR) brachytherapy for cancer of the cervix in Brazil, regarding apparatuses, planning methods, prescription, fractionation schedule and evaluation of dose in organs at risk. Materials and methods: in the period between March/2012 and May/2013, a multiple choice questionnaire was developed and sent to 89 Brazilian hospitals which perform HDR brachytherapy. Results: sixty-one services answered the questionnaire. All regions of the country experienced a sharp increase in the number of HDR brachytherapy services in the period from 2001 to 2013. As regards planning, although a three-dimensional planning software was available in 91% of the centers, conventional radiography was mentioned by 92% of the respondents as their routine imaging method for such a purpose. Approximately 35% of respondents said that brachytherapy sessions are performed after teletherapy. The scheme of four 7 Gy intracavitary insertions was mentioned as the most frequently practiced. Conclusion: the authors observed that professionals have difficulty accessing adjuvant three-dimensional planning tools such as computed tomography and magnetic resonance imaging. (author)

  6. High Dose Rate Brachytherapy as a Treatment Option in Endobronchial Tumors

    Directory of Open Access Journals (Sweden)

    Ali Hosni

    2016-01-01

    Full Text Available Purpose. To report our experience with high dose rate endobronchial brachytherapy (HDR-EBBT and to assess its efficacy and tolerability with possibility of its use in selected cases with curative intent. Method. Retrospective review of patients with endobronchial tumors treated at our institution in 2007–2013 with HDR-EBBT. Subjective response and treatment related toxicity were extracted from patients’ records. Clinical response was evaluated by chest CT +/− bronchoscopy 2-3 months after treatment. Local control (LC and overall survival (OS were analyzed. Results. Overall 23 patients were identified. Ten patients were treated with curative intent, in 8 of them HDR-EBBT was combined with external beam radiotherapy. Short term palliation was as follows: dyspnea (13/15, cough (12/14, and hemoptysis (3/3. Seventeen patients were evaluated, of whom 9 (53% showed complete response. Four patients developed local failure (only 1 of them treated with curative intent and were salvaged with HDR-EBBT (n=1, chemotherapy (n=2, and laser (n=1. Among patients treated with curative intent, the 2-year LC and OS were 89% and 67%, respectively, and 2 out of 4 deaths were cancer-related. Late toxicity included bronchial stenosis (n=1. Only 1 patient had fatal hemoptysis and postmortem examination indicated local recurrence. Conclusion. HDR-EBBT is promising treatment with tolerable complication if used in properly selected patients.

  7. [A Quality Assurance (QA) System with a Web Camera for High-dose-rate Brachytherapy].

    Science.gov (United States)

    Hirose, Asako; Ueda, Yoshihiro; Oohira, Shingo; Isono, Masaru; Tsujii, Katsutomo; Inui, Shouki; Masaoka, Akira; Taniguchi, Makoto; Miyazaki, Masayoshi; Teshima, Teruki

    2016-03-01

    The quality assurance (QA) system that simultaneously quantifies the position and duration of an (192)Ir source (dwell position and time) was developed and the performance of this system was evaluated in high-dose-rate brachytherapy. This QA system has two functions to verify and quantify dwell position and time by using a web camera. The web camera records 30 images per second in a range from 1,425 mm to 1,505 mm. A user verifies the source position from the web camera at real time. The source position and duration were quantified with the movie using in-house software which was applied with a template-matching technique. This QA system allowed verification of the absolute position in real time and quantification of dwell position and time simultaneously. It was evident from the verification of the system that the mean of step size errors was 0.31±0.1 mm and that of dwell time errors 0.1±0.0 s. Absolute position errors can be determined with an accuracy of 1.0 mm at all dwell points in three step sizes and dwell time errors with an accuracy of 0.1% in more than 10.0 s of the planned time. This system is to provide quick verification and quantification of the dwell position and time with high accuracy at various dwell positions without depending on the step size.

  8. Survival of tumor cells after proton irradiation with ultra-high dose rates

    Directory of Open Access Journals (Sweden)

    Belka Claus

    2011-10-01

    Full Text Available Abstract Background Laser acceleration of protons and heavy ions may in the future be used in radiation therapy. Laser-driven particle beams are pulsed and ultra high dose rates of >109 Gy s-1may be achieved. Here we compare the radiobiological effects of pulsed and continuous proton beams. Methods The ion microbeam SNAKE at the Munich tandem accelerator was used to directly compare a pulsed and a continuous 20 MeV proton beam, which delivered a dose of 3 Gy to a HeLa cell monolayer within Results At 10 h after pulsed irradiation, the fraction of G2 cells was significantly lower than after irradiation with the continuous beam, while all other endpoints including colony formation were not significantly different. We determined the relative biological effectiveness (RBE for pulsed and continuous proton beams relative to x-irradiation as 0.91 ± 0.26 and 0.86 ± 0.33 (mean and SD, respectively. Conclusions At the dose rates investigated here, which are expected to correspond to those in radiation therapy using laser-driven particles, the RBE of the pulsed and the (conventional continuous irradiation mode do not differ significantly.

  9. Perioperative high-dose-rate brachytherapy in the treatment of recurrent malignant gliomas

    Energy Technology Data Exchange (ETDEWEB)

    Fabrini, Maria Grazia; Pasqualetti, Francesco; Grespi, Silvia [Div. of Radiation Oncology, ' ' S. Chiara' ' Pisa Hospital (Italy); Perrone, Franco [Div. of Health Physics, ' ' S. Chiara' ' Pisa Hospital (Italy); De Franco, Lucia; Vannozzi, Riccardo [Div. of Neurosurgery, ' ' S. Chiara' ' Pisa Hospital (Italy); Cionini, Luca [Div. of Radiation Oncology, ' ' S. Chiara' ' Pisa Hospital (Italy); Pisa Univ. (Italy)

    2009-08-15

    Purpose: To assess the feasibility and effectiveness of perioperative high-dose-rate brachytherapy for recurrent malignant gliomas. Patients and Methods: Between 2005 and 2008, 21 patients (14 males and seven females) with relapsed malignant glioma underwent a second surgery followed by a brachytherapy implant in the surgical cavity. Median age was 60 years, and median Karnofsky performance status 80. A single fraction of 18 Gy specified at 5 mm depth was administered perioperatively. Then, the applicator was removed nonsurgically. Mean postoperative hospitalization time was 3 days. Results: At the time of analysis, 15 patients (71%) had died and six (29%) were alive. Median follow-up was 32.3 months. Median overall survival from diagnosis amounted to 21.7 months. Median survival after recurrence was 8.0 months, and 6-month progression-free survival 42%. Patients were stratified into classes according to the prognostic recursive partitioning analysis. Conclusion: Perioperative brachytherapy has proven to be safe and well tolerated in patients with recurrent malignant glioma. No severe toxicity was reported, and the treatment has proven to be effective in symptomatic recurrences of malignant gliomas. (orig.)

  10. Determination of the tissue inhomogeneity correction in high dose rate Brachytherapy for Iridium-192 source

    Directory of Open Access Journals (Sweden)

    Barlanka Ravikumar

    2012-01-01

    Full Text Available In Brachytherapy treatment planning, the effects of tissue heterogeneities are commonly neglected due to lack of accurate, general and fast three-dimensional (3D dose-computational algorithms. In performing dose calculations, it is assumed that the tumor and surrounding tissues constitute a uniform, homogeneous medium equivalent to water. In the recent past, three-dimensional computed tomography (3D-CT based treatment planning for Brachytherapy applications has been popularly adopted. However, most of the current commercially available planning systems do not provide the heterogeneity corrections for Brachytherapy dosimetry. In the present study, we have measured and quantified the impact of inhomogeneity caused by different tissues with a 0.015 cc ion chamber. Measurements were carried out in wax phantom which was employed to measure the heterogeneity. Iridium-192 (192 Ir source from high dose rate (HDR Brachytherapy machine was used as the radiation source. The reduction of dose due to tissue inhomogeneity was measured as the ratio of dose measured with different types of inhomogeneity (bone, spleen, liver, muscle and lung to dose measured with homogeneous medium for different distances. It was observed that different tissues attenuate differently, with bone tissue showing maximum attenuation value and lung tissue resulting minimum value and rest of the tissues giving values lying in between those of bone and lung. It was also found that inhomogeneity at short distance is considerably more than that at larger distances.

  11. On the use of multi-dimensional scaling and electromagnetic tracking in high dose rate brachytherapy.

    Science.gov (United States)

    Götz, Theresa Ida; Ermer, Maximilian; Salas-Gonzalez, D; Kellermeier, Markus; Strnad, Vratislav; Bert, Christoph; Hensel, Bernhard; Tome, Ana Maria; Lang, Elmar W

    2017-08-30

    High Dose Rate Brachytherapy (HDR-BT) affords a frequent reassurance of the precise dwell positions of the radiation source. The corresponding dwell position determinations are realized with an electromagnetic tracking system (EMT). Because the treatment extends over several days, repeated dwell position determinations refer to varying coordinate systems centered in the field generator of the EMT system. After surgical implantation of the catheters a computed tomography (CT) X-ray image is taken followed by an immediate dwell position determination by the EMT system. The CT image serves to generate a treatment plan which determines dwell positions and dwell times for the radiation treatment. However, CT - and EMT - coordinates refer to different coordinate systems, hence an external reference is usually employed. The current investigation proposes a multi-dimensional scaling transformation of both data sets to estimate dwell positions without any external reference. Furthermore, the related distributions of dwell positions are characterized by uni - or bi - modal heavy - tailed distributions. The latter are well represented by alpha - stable distributions. The newly proposed data analysis provides dwell position deviations with high accuracy, and, furthermore, offers a convenient visualization of the actual shapes of the catheters which guide the radiation source during the treatment. © 2017 Institute of Physics and Engineering in Medicine.

  12. Salvage high-dose-rate brachytherapy for isolated vaginal recurrence of endometrial cancer.

    Science.gov (United States)

    Baek, Sungjae; Isohashi, Fumiaki; Yamaguchi, Hiroko; Mabuchi, Seiji; Yoshida, Ken; Kotsuma, Tadayuki; Yamazaki, Hideya; Tanaka, Eiichi; Sumida, Iori; Tamari, Keisuke; Otani, Keisuke; Seo, Yuji; Suzuki, Osamu; Yoshioka, Yasuo; Kimura, Tadashi; Ogawa, Kazuhiko

    We have retrospectively analyzed the outcomes of high-dose-rate (HDR) brachytherapy as a salvage therapy for vaginal recurrence of endometrial cancer. From 1997 to 2012, salvage HDR brachytherapy was performed in 43 patients. The median age was 64 years (range, 41-88 years). HDR brachytherapy was performed by interstitial brachytherapy in 34 patients (79%) and by intracavity brachytherapy in nine patients (21%). Seventeen (40%) of the 43 patients were treated with external beam radiotherapy. The median followup period was 58 months (range, 6-179 months). The 5-year overall survival (OS), progression-free survival (PFS), and local control rates (LC) were 84%, 52%, and 78%, respectively. Patients who received brachytherapy with external beam radiotherapy experienced no nodal recurrence (0 of 17 patients), whereas 23% of the patients (6 of 26 patients) who received brachytherapy alone experienced nodal recurrence (p = 0.047). The pathologic grade at the time of initial surgery (G1-2 vs. G3) was found to be a significant prognostic factor for both OS and PFS. The respective 5-year OS was 96% vs. 40% (p endometrial cancer. Pathologic grade, age, and modality were significant prognostic factors. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  13. Evaluation of Rectal Dose During High-Dose-Rate Intracavitary Brachytherapy for Cervical Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Sha, Rajib Lochan [Department of Radiation Physics, Indo-American Cancer Institute and Research Centre, Hyderabad (India); Department of Physics, Osmania University, Hyderabad (India); Reddy, Palreddy Yadagiri [Department of Physics, Osmania University, Hyderabad (India); Rao, Ramakrishna [Department of Radiation Physics, MNJ Institute of Oncology and Regional Cancer Center, Hyderabad (India); Muralidhar, Kanaparthy R. [Department of Radiation Physics, Indo-American Cancer Institute and Research Centre, Hyderabad (India); Kudchadker, Rajat J., E-mail: rkudchad@mdanderson.org [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States)

    2011-01-01

    High-dose-rate intracavitary brachytherapy (HDR-ICBT) for carcinoma of the uterine cervix often results in high doses being delivered to surrounding organs at risk (OARs) such as the rectum and bladder. Therefore, it is important to accurately determine and closely monitor the dose delivered to these OARs. In this study, we measured the dose delivered to the rectum by intracavitary applications and compared this measured dose to the International Commission on Radiation Units and Measurements rectal reference point dose calculated by the treatment planning system (TPS). To measure the dose, we inserted a miniature (0.1 cm{sup 3}) ionization chamber into the rectum of 86 patients undergoing radiation therapy for cervical carcinoma. The response of the miniature chamber modified by 3 thin lead marker rings for identification purposes during imaging was also characterized. The difference between the TPS-calculated maximum dose and the measured dose was <5% in 52 patients, 5-10% in 26 patients, and 10-14% in 8 patients. The TPS-calculated maximum dose was typically higher than the measured dose. Our study indicates that it is possible to measure the rectal dose for cervical carcinoma patients undergoing HDR-ICBT. We also conclude that the dose delivered to the rectum can be reasonably predicted by the TPS-calculated dose.

  14. Toward endobronchial Ir-192 high-dose-rate brachytherapy therapeutic optimization

    Energy Technology Data Exchange (ETDEWEB)

    Gay, H A [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Allison, R R [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Downie, G H [Section of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Mota, H C [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Austerlitz, C [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Jenkins, T [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Sibata, C H [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States)

    2007-06-07

    A number of patients with lung cancer receive either palliative or curative high-dose-rate (HDR) endobronchial brachytherapy. Up to a third of patients treated with endobronchial HDR die from hemoptysis. Rather than accept hemoptysis as an expected potential consequence of HDR, we have calculated the radial dose distribution for an Ir-192 HDR source, rigorously examined the dose and prescription points recommended by the American Brachytherapy Society (ABS), and performed a radiobiological-based analysis. The radial dose rate of a commercially available Ir-192 source was calculated with a Monte Carlo simulation. Based on the linear quadratic model, the estimated palliative, curative and blood vessel rupture radii from the center of an Ir-192 source were obtained for the ABS recommendations and a series of customized HDR prescriptions. The estimated radius at risk for blood vessel perforation for the ABS recommendations ranges from 7 to 9 mm. An optimized prescription may in some situations reduce this radius to 4 mm. The estimated blood perforation radius is generally smaller than the palliative radius. Optimized and individualized endobronchial HDR prescriptions are currently feasible based on our current understanding of tumor and normal tissue radiobiology. Individualized prescriptions could minimize complications such as fatal hemoptysis without sacrificing efficacy. Fiducial stents, HDR catheter centering or spacers and the use of CT imaging to better assess the relationship between the catheter and blood vessels promise to be useful strategies for increasing the therapeutic index of this treatment modality. Prospective trials employing treatment optimization algorithms are needed.

  15. High-dose-rate interstitial brachytherapy for the treatment of penile carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Petera, J.; Odrazka, K.; Zouhar, M.; Bedrosova, J.; Dolezel, M. [Dept. of Oncology and Radiotherapy, Charles Univ. Medical School and Teaching Hospital, Hradec Kralove (Czech Republic)

    2004-02-01

    Background: interstitial low-dose-rate (LDR) brachytherapy allows conservative treatment of T1-T2 penile carcinoma. High-dose-rate (HDR) is often considered to be dangerous for interstitial implants because of a higher risk of complications, but numerous reports suggest that results may be comparable to LDR. Nevertheless, there are no data in the literature available regarding HDR interstitial brachytherapy for carcinoma of the penis. Case report: a 64-year-old man with T1 NO MO epidermoid carcinoma of the glans is reported. Interstitial HDR brachytherapy was performed using the stainless hollow needle technique and a breast template for fixation and good geometry. The dose delivered was 18 x 3 Gy twice daily. Results: after 232 days from brachytherapy, the patient was without any evidence of the tumor, experienced no serious radiation-induced complications, and had a fully functional organ. Conclusion: HDR interstitial brachytherapy is feasible in selected case of penis carcinoma, when careful planning and small single fractions are used. (orig.)

  16. Impact of surface curvature on dose delivery in intraoperative high-dose-rate brachytherapy.

    Science.gov (United States)

    Oh, Moonseong; Wang, Zhou; Malhotra, Harish K; Jaggernauth, Wainwright; Podgorsak, Matthew B

    2009-01-01

    In intraoperative high-dose-rate (IOHDR) brachytherapy, a 2-dimensional (2D) geometry is typically used for treatment planning. The assumption of planar geometry may cause serious errors in dose delivery for target surfaces that are, in reality, curved. A study to evaluate the magnitude of these errors in clinical practice was undertaken. Cylindrical phantoms with 6 radii (range: 1.35-12.5 cm) were used to simulate curved treatment geometries. Treatment plans were developed for various planar geometries and were delivered to the cylindrical phantoms using catheters inserted into Freiburg applicators of varying dimension. Dose distributions were measured using radiographic film. In comparison to the treatment plan (for a planar geometry), the doses delivered to prescription points were higher on the concave side of the geometry, up to 15% for the phantom with the smallest radius. On the convex side of the applicator, delivered doses were up to 10% lower for small treated areas (5 catheters). Our measurements have shown inaccuracy in dose delivery when the original planar treatment plan is delivered with a curved applicator. Dose delivery errors arising from the use of planar treatment plans with curved applicators may be significant.

  17. 3D-printed applicators for high dose rate brachytherapy: Dosimetric assessment at different infill percentage.

    Science.gov (United States)

    Ricotti, Rosalinda; Vavassori, Andrea; Bazani, Alessia; Ciardo, Delia; Pansini, Floriana; Spoto, Ruggero; Sammarco, Vittorio; Cattani, Federica; Baroni, Guido; Orecchia, Roberto; Jereczek-Fossa, Barbara Alicja

    2016-12-01

    Dosimetric assessment of high dose rate (HDR) brachytherapy applicators, printed in 3D with acrylonitrile butadiene styrene (ABS) at different infill percentage. A low-cost, desktop, 3D printer (Hamlet 3DX100, Hamlet, Dublin, IE) was used for manufacturing simple HDR applicators, reproducing typical geometries in brachytherapy: cylindrical (common in vaginal treatment) and flat configurations (generally used to treat superficial lesions). Printer accuracy was investigated through physical measurements. The dosimetric consequences of varying the applicator's density by tuning the printing infill percentage were analysed experimentally by measuring depth dose profiles and superficial dose distribution with Gafchromic EBT3 films (International Specialty Products, Wayne, NJ). Dose distributions were compared to those obtained with a commercial superficial applicator. Measured printing accuracy was within 0.5mm. Dose attenuation was not sensitive to the density of the material. Surface dose distribution comparison of the 3D printed flat applicators with respect to the commercial superficial applicator showed an overall passing rate greater than 94% for gamma analysis with 3% dose difference criteria, 3mm distance-to-agreement criteria and 10% dose threshold. Low-cost 3D printers are a promising solution for the customization of the HDR brachytherapy applicators. However, further assessment of 3D printing techniques and regulatory materials approval are required for clinical application. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. Comparative dosimetry of GammaMed Plus high-dose rate 192 Ir brachytherapy source

    Directory of Open Access Journals (Sweden)

    Patel N

    2010-01-01

    Full Text Available The comparative dosimetry of GammaMed (GM Plus high-dose rate brachytherapy source was performed by an experiment using 0.1-cc thimble ionization chamber and simulation-based study using EGSnrc code. In-water dose measurements were performed with 0.1-cc chamber to derive the radial dose function (r = 0.8 to 20.0 cm and anisotropy function (r = 5.0 cm with polar angle from 10° to 170°. The nonuniformity correction factor for 0.1-cc chamber was applied for in-water measurements at shorter distances from the source. The EGSnrc code was used to derive the dose rate constant (L, radial dose function g L (r and anisotropy function F(r, q of GM Plus source. The dosimetric data derived using EGSnrc code in our study were in very good agreement relative to published data for GM Plus source. The radial dose function up to 12 cm derived from measured dose using 0.1-cc chamber was in agreement within ±3% of data derived by the simulation study.

  19. Dosimetric perturbations of a lead shield for surface and interstitial high-dose-rate brachytherapy.

    Science.gov (United States)

    Candela-Juan, Cristian; Granero, Domingo; Vijande, Javier; Ballester, Facundo; Perez-Calatayud, Jose; Rivard, Mark J

    2014-06-01

    In surface and interstitial high-dose-rate brachytherapy with either (60)Co, (192)Ir, or (169)Yb sources, some radiosensitive organs near the surface may be exposed to high absorbed doses. This may be reduced by covering the implants with a lead shield on the body surface, which results in dosimetric perturbations. Monte Carlo simulations in Geant4 were performed for the three radionuclides placed at a single dwell position. Four different shield thicknesses (0, 3, 6, and 10 mm) and three different source depths (0, 5, and 10 mm) in water were considered, with the lead shield placed at the phantom surface. Backscatter dose enhancement and transmission data were obtained for the lead shields. Results were corrected to account for a realistic clinical case with multiple dwell positions. The range of the high backscatter dose enhancement in water is 3 mm for (60)Co and 1 mm for both (192)Ir and (169)Yb. Transmission data for (60)Co and (192)Ir are smaller than those reported by Papagiannis et al (2008 Med. Phys. 35 4898-4906) for brachytherapy facility shielding; for (169)Yb, the difference is negligible. In conclusion, the backscatter overdose produced by the lead shield can be avoided by just adding a few millimetres of bolus. Transmission data provided in this work as a function of lead thickness can be used to estimate healthy organ equivalent dose saving. Use of a lead shield is justified.

  20. Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'

    Science.gov (United States)

    Salter, Bill J.; Sarkar, Vikren; Wang, Brian; Shukla, Himanshu; Szegedi, Martin; Rassiah-Szegedi, Prema

    2011-04-01

    Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units per minute (MU min-1) high dose rate bursts of dose are facilitated by a flattening-filter-free treatment beam on a Siemens Artiste (Oncology Care Systems, Siemens Medical Solutions, Concord, CA, USA) digital linear accelerator in a non-clinical configuration. Burst mode delivery differs from continuous mode delivery, used by Elekta's VMAT (Elekta Ltd, Crawley, UK) and Varian's RapidArc (Varian Medical Systems, Palo Alto, CA, USA) implementations, in that dose is not delivered while MLC leaves are moving. Instead, dose is delivered in bursts over very short arc angles and only after an MLC segment shape has been completely formed and verified by the controller. The new system was confirmed to be capable of delivering a wide array of clinically relevant treatment plans, without machine fault or other delivery anomalies. Dosimetric accuracy of the modulated arc platform, as well as the Prowess (Prowess Inc., Concord, CA, USA) prototype treatment planning version utilized here, was quantified and confirmed, and delivery times were measured as significantly brief, even with large hypofractionated doses. The burst mode modulated arc approach evaluated here appears to represent a capable, accurate and efficient delivery approach.

  1. High-Dose-Rate Monotherapy: Safe and Effective Brachytherapy for Patients With Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Demanes, D. Jeffrey, E-mail: jdemanes@mednet.ucla.edu [California Endocurietherapy at UCLA, Department of Radiation Oncology, David Geffen School of Medicine of University of California at Los Angeles, Los Angeles, CA (United States); Martinez, Alvaro A.; Ghilezan, Michel [William Beaumont Hospital, Royal Oak, MI (United States); Hill, Dennis R.; Schour, Lionel; Brandt, David [California Endocurietherapy, Oakland, CA (United States); Gustafson, Gary [William Beaumont Hospital, Royal Oak, MI (United States)

    2011-12-01

    Purpose: High-dose-rate (HDR) brachytherapy used as the only treatment (monotherapy) for early prostate cancer is consistent with current concepts in prostate radiobiology, and the dose is reliably delivered in a prospectively defined anatomic distribution that meets all the requirements for safe and effective therapy. We report the disease control and toxicity of HDR monotherapy from California Endocurietherapy (CET) and William Beaumont Hospital (WBH) in low- and intermediate-risk prostate cancer patients. Methods and Materials: There were 298 patients with localized prostate cancer treated with HDR monotherapy between 1996 and 2005. Two biologically equivalent hypofractionation protocols were used. At CET the dose was 42 Gy in six fractions (two implantations 1 week apart) delivered to a computed tomography-defined planning treatment volume. At WBH the dose was 38 Gy in four fractions (one implantation) based on intraoperative transrectal ultrasound real-time treatment planning. The bladder, urethral, and rectal dose constraints were similar. Toxicity was scored with the National Cancer Institute Common Toxicity Criteria for Adverse Events version 3. Results: The median follow-up time was 5.2 years. The median age of the patients was 63 years, and the median value of the pretreatment prostate-specific antigen was 6.0 ng/mL. The 8-year results were 99% local control, 97% biochemical control (nadir +2), 99% distant metastasis-free survival, 99% cause-specific survival, and 95% overall survival. Toxicity was scored per event, meaning that an individual patient with more than one symptom was represented repeatedly in the morbidity data table. Genitourinary toxicity consisted of 10% transient Grade 2 urinary frequency or urgency and 3% Grade 3 episode of urinary retention. Gastrointestinal toxicity was <1%. Conclusions: High disease control rates and low morbidity demonstrate that HDR monotherapy is safe and effective for patients with localized prostate cancer.

  2. Quality control of high-dose-rate brachytherapy: treatment delivery analysis using statistical process control.

    Science.gov (United States)

    Able, Charles M; Bright, Megan; Frizzell, Bart

    2013-03-01

    Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Quality Control of High-Dose-Rate Brachytherapy: Treatment Delivery Analysis Using Statistical Process Control

    Energy Technology Data Exchange (ETDEWEB)

    Able, Charles M., E-mail: cable@wfubmc.edu [Department of Radiation Oncology, Wake Forest School of Medicine, Winston-Salem, North Carolina (United States); Bright, Megan; Frizzell, Bart [Department of Radiation Oncology, Wake Forest School of Medicine, Winston-Salem, North Carolina (United States)

    2013-03-01

    Purpose: Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. Methods and Materials: A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. Results: There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. Conclusions: SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy.

  4. Clinical implementation of a novel applicator in high-dose-rate brachytherapy treatment of esophageal cancer

    Directory of Open Access Journals (Sweden)

    Ivan M. Buzurovic

    2016-08-01

    Full Text Available Purpose : In this study, we present the clinical implementation of a novel transoral balloon centering esophageal applicator (BCEA and the initial clinical experience in high-dose-rate (HDR brachytherapy treatment of esophageal cancer, using this applicator. Material and methods: Acceptance testing and commissioning of the BCEA were performed prior to clinical use. Full performance testing was conducted including measurements of the dimensions and the catheter diameter, evaluation of the inflatable balloon consistency, visibility of the radio-opaque markers, congruence of the markers, absolute and relative accuracy of the HDR source in the applicator using the radiochromic film and source position simulator, visibility and digitization of the applicator on the computed tomography (CT images under the clinical conditions, and reproducibility of the offset. Clinical placement of the applicator, treatment planning, treatment delivery, and patient’s response to the treatment were elaborated as well. Results : The experiments showed sub-millimeter accuracy in the source positioning with distal position at 1270 mm. The digitization (catheter reconstruction was uncomplicated due to the good visibility of markers. The treatment planning resulted in a favorable dose distribution. This finding was pronounced for the treatment of the curvy anatomy of the lesion due to the improved repeatability and consistency of the delivered fractional dose to the patient, since the radioactive source was placed centrally within the lumen with respect to the clinical target due to the five inflatable balloons. Conclusions : The consistency of the BCEA positioning resulted in the possibility to deliver optimized non-uniform dose along the catheter, which resulted in an increase of the dose to the cancerous tissue and lower doses to healthy tissue. A larger number of patients and long-term follow-up will be required to investigate if the delivered optimized treatment can

  5. Dosimetric evaluation of two treatment planning systems for high dose rate brachytherapy applications

    Energy Technology Data Exchange (ETDEWEB)

    Shwetha, Bondel [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Ravikumar, Manickam, E-mail: drravikumarm@gmail.com [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Supe, Sanjay S.; Sathiyan, Saminathan [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Lokesh, Vishwanath [Department of Radiotherapy, Kidwai, Memorial Institute of Oncology, Bangalore (India); Keshava, Subbarao L. [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India)

    2012-04-01

    Various treatment planning systems are used to design plans for the treatment of cervical cancer using high-dose-rate brachytherapy. The purpose of this study was to make a dosimetric comparison of the 2 treatment planning systems from Varian medical systems, namely ABACUS and BrachyVision. The dose distribution of Ir-192 source generated with a single dwell position was compared using ABACUS (version 3.1) and BrachyVision (version 6.5) planning systems. Ten patients with intracavitary applications were planned on both systems using orthogonal radiographs. Doses were calculated at the prescription points (point A, right and left) and reference points RU, LU, RM, LM, bladder, and rectum. For single dwell position, little difference was observed in the doses to points along the perpendicular bisector. The mean difference between ABACUS and BrachyVision for these points was 1.88%. The mean difference in the dose calculated toward the distal end of the cable by ABACUS and BrachyVision was 3.78%, whereas along the proximal end the difference was 19.82%. For the patient case there was approximately 2% difference between ABACUS and BrachyVision planning for dose to the prescription points. The dose difference for the reference points ranged from 0.4-1.5%. For bladder and rectum, the differences were 5.2% and 13.5%, respectively. The dose difference between the rectum points was statistically significant. There is considerable difference between the dose calculations performed by the 2 treatment planning systems. It is seen that these discrepancies are caused by the differences in the calculation methodology adopted by the 2 systems.

  6. Single versus multichannel applicator in high-dose-rate vaginal brachytherapy optimized by inverse treatment planning.

    Science.gov (United States)

    Bahadur, Yasir A; Constantinescu, Camelia; Hassouna, Ashraf H; Eltaher, Maha M; Ghassal, Noor M; Awad, Nesreen A

    2015-01-01

    To retrospectively compare the potential dosimetric advantages of a multichannel vaginal applicator vs. a single channel one in intracavitary vaginal high-dose-rate (HDR) brachytherapy after hysterectomy, and evaluate the dosimetric advantage of fractional re-planning. We randomly selected 12 patients with endometrial carcinoma, who received adjuvant vaginal cuff HDR brachytherapy using a multichannel applicator. For each brachytherapy fraction, two inverse treatment plans (for central channel and multichannel loadings) were performed and compared. The advantage of fractional re-planning was also investigated. Dose-volume-histogram (DVH) analysis showed limited, but statistically significant difference (p = 0.007) regarding clinical-target-volume dose coverage between single and multichannel approaches. For the organs-at-risk rectum and bladder, the use of multichannel applicator demonstrated a noticeable dose reduction, when compared to single channel, but statistically significant for rectum only (p = 0.0001). For D2cc of rectum, an average fractional dose of 6.1 ± 0.7 Gy resulted for single channel vs. 5.1 ± 0.6 Gy for multichannel. For D2cc of bladder, an average fractional dose of 5 ± 0.9 Gy occurred for single channel vs. 4.9 ± 0.8 Gy for multichannel. The dosimetric benefit of fractional re-planning was demonstrated: DVH analysis showed large, but not statistically significant differences between first fraction plan and fractional re-planning, due to large inter-fraction variations for rectum and bladder positioning and filling. Vaginal HDR brachytherapy using a multichannel vaginal applicator and inverse planning provides dosimetric advantages over single channel cylinder, by reducing the dose to organs at risk without compromising the target volume coverage, but at the expense of an increased vaginal mucosa dose. Due to large inter-fraction dose variations, we recommend individual fraction treatment plan optimization.

  7. Robustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements

    Science.gov (United States)

    Whitaker, May

    2016-01-01

    Purpose Inverse planning simulated annealing (IPSA) optimized brachytherapy treatment plans are characterized with large isolated dwell times at the first or last dwell position of each catheter. The potential of catheter shifts relative to the target and organs at risk in these plans may lead to a more significant change in delivered dose to the volumes of interest relative to plans with more uniform dwell times. Material and methods This study aims to determine if the Nucletron Oncentra dwell time deviation constraint (DTDC) parameter can be optimized to improve the robustness of high-dose-rate (HDR) prostate brachytherapy plans to catheter displacements. A set of 10 clinically acceptable prostate plans were re-optimized with a DTDC parameter of 0 and 0.4. For each plan, catheter displacements of 3, 7, and 14 mm were retrospectively applied and the change in dose volume histogram (DVH) indices and conformity indices analyzed. Results The robustness of clinically acceptable prostate plans to catheter displacements in the caudal direction was found to be dependent on the DTDC parameter. A DTDC value of 0 improves the robustness of planning target volume (PTV) coverage to catheter displacements, whereas a DTDC value of 0.4 improves the robustness of the plans to changes in hotspots. Conclusions The results indicate that if used in conjunction with a pre-treatment catheter displacement correction protocol and a tolerance of 3 mm, a DTDC value of 0.4 may produce clinically superior plans. However, the effect of the DTDC parameter in plan robustness was not observed to be as strong as initially suspected. PMID:27504129

  8. High dose rate interstitial brachytherapy in soft tissue sarcomas: technical aspect

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Mi Son; Kang, Seung Hee; Kim, Byoung Suck; Oh, Young Taek [College of Medicine, Ajou Univ., Suwon (Korea, Republic of)

    1999-03-01

    To discuss the technical aspect of interstitial brachytherapy including method of implant, insertion time of radioactive source, total radiation dose, and complication, we reviewed patients who had diagnoses of soft tissue sarcoma and were treated by conservative surgery, interstitial implant and external beam radiation therapy. Between May 1995 and Dec. 1997, the patients with primary or recurrent soft tissue sarcoma underwent surgical resection (wide margin excision) and received radiotherapy including interstitial brachytherapy. Catheters were placed with regular intervals of 1-1.5 cm immediately after tumor removal and covering the critical structures, such as neurovascular bundle or bone, with gelform, muscle, or tissue expander in the cases where the tumors were close to those structures. Brachytherapy consisted of source axis with 2-2.5 Gy/fraction, twice a day, starting on 6th day after the surgery. Within one month after the surgery, total dose of 50-55 Gy was delivered to the tumor bed with wide margin by the external beam radiotherapy. All patients completed planned interstitial brachytherapy without acute side effects directly related with catheter implantation such as infection or bleeding. With median follow up duration of 25 months (range 12-41 months), no local recurrences were observed. And there was no severe form of chromic complication (RTOG/EORTC grade 3 or 4). The high dose rate interstitial brachytherapy is easy and safe way to minimize the radiation dose delivered to the adjacent normal tissue and to decrease radiation induced chronic morbidity such as fibrosis by reducing the total dose of external radiotherapy in the management of soft tissue sarcoma with conservative surgery.

  9. Brachytherapy for early oral tongue cancer. Low dose rate to high dose rate

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Hideya [Toyonaka Municipal Hospital, Osaka (Japan); Inoue, Takehiro; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Inoue, Toshihiko [Osaka Univ., Suita (Japan). Graduate School of Medicine; Furukawa, Souhei; Kakimoto, Naoya [Osaka Univ., Suita (Japan). Graduate School of Dentistry

    2003-03-01

    To examine the compatibility of low dose rate (LDR) with high dose rate (HDR) brachytherapy, we reviewed 399 patients with early oral tongue cancer (T1-2N0M0) treated solely by brachytherapy at Osaka University Hospital between 1967 and 1999. For patients in the LDR group (n=341), the treatment sources consisted of Ir-192 pin for 227 patients (1973-1996; irradiated dose, 61-85 Gy; median, 70 Gy), Ra-226 needle for 113 patients (1967-1986; 55-93 Gy; median, 70 Gy). Ra-226 and Ir-192 were combined for one patient. Ir-192 HDR (microSelectron-HDR) was used for 58 patients in the HDR group (1991-present; 48-60 Gy; median, 60 Gy). LDR implantations were performed via oral and HDR via a submental/submandibular approach. The dose rates at the reference point for the LDR group were 0.30 to 0.8 Gy/h, and for the HDR group 1.0 to 3.4 Gy/min. The patients in the HDR group received a total dose of 48-60 Gy (8-10 fractions) during one week. Two fractions were administered per day (at least a 6-h interval). The 3- and 5-year local control rates for patients in the LDR group were 85% and 80%, respectively, and those in the HDR group were both 84%. HDR brachytherapy showed the same lymph-node control rate as did LDR brachytherapy (67% at 5 years). HDR brachytherapy achieved the same locoregional result as did LDR brachytherapy. A converting factor of 0.86 is applicable for HDR in the treatment of early oral tongue cancer. (author)

  10. High dose rates obtained outside ISS in June 2015 during SEP event.

    Science.gov (United States)

    Dachev, T P; Tomov, B T; Matviichuk, Yu N; Dimitrov, Pl G; Bankov, N G

    2016-06-01

    The R3DR2 instrument performed measurements in the European Space Agency (ESA) EXPOSE-R2 platform outside the Russian "Zvezda" module of the International Space Station (ISS) in the period 24 October 2014-11 January 2016. It is the Liulin-type deposited energy spectrometer (DES) (Dachev et al., 2015a). Took place in November 2014, this was the first attempt to monitor a small solar energetic particle (SEP) event outside ISS using the Liulin-type DES (Dachev et al., 2015d). In this study, we describe the dosimetric characteristics of the largest SEP event, observed on 22 June 2015 with the R3DR2 instrument outside ISS. The main finding of this study is that SEP protons with a minimum energy of approximately 7MeV at the surface of the R3DR2 detector produced high dose rates, reaching >5000µGyh(-1), while the inner radiation belt maximum dose was at the level of 2200µGyh(-1). If a virtual external vehicle activity (EVA) was performed in the same period of the SEP maximum on 22 June 2015, the doses obtained in the skin of cosmonauts/astronauts can reach 2.84mGy after 6.5h, which is similar to the average absorbed dose inside ISS for 15days (Reitz et al., 2005). A comparison with other extreme events measured with Liulin-type instruments shows that SEPs similar to that observed on 22 June 2015 could be one of the most dangerous events for the cosmonauts/astronauts involved in EVA. Copyright © 2016 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.

  11. An automated optimization tool for high-dose-rate (HDR) prostate brachytherapy with divergent needle pattern

    Science.gov (United States)

    Borot de Battisti, M.; Maenhout, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; van Vulpen, M.; Moerland, M. A.

    2015-10-01

    Focal high-dose-rate (HDR) for prostate cancer has gained increasing interest as an alternative to whole gland therapy as it may contribute to the reduction of treatment related toxicity. For focal treatment, optimal needle guidance and placement is warranted. This can be achieved under MR guidance. However, MR-guided needle placement is currently not possible due to space restrictions in the closed MR bore. To overcome this problem, a MR-compatible, single-divergent needle-implant robotic device is under development at the University Medical Centre, Utrecht: placed between the legs of the patient inside the MR bore, this robot will tap the needle in a divergent pattern from a single rotation point into the tissue. This rotation point is just beneath the perineal skin to have access to the focal prostate tumor lesion. Currently, there is no treatment planning system commercially available which allows optimization of the dose distribution with such needle arrangement. The aim of this work is to develop an automatic inverse dose planning optimization tool for focal HDR prostate brachytherapy with needle insertions in a divergent configuration. A complete optimizer workflow is proposed which includes the determination of (1) the position of the center of rotation, (2) the needle angulations and (3) the dwell times. Unlike most currently used optimizers, no prior selection or adjustment of input parameters such as minimum or maximum dose or weight coefficients for treatment region and organs at risk is required. To test this optimizer, a planning study was performed on ten patients (treatment volumes ranged from 8.5 cm3to 23.3 cm3) by using 2-14 needle insertions. The total computation time of the optimizer workflow was below 20 min and a clinically acceptable plan was reached on average using only four needle insertions.

  12. Prostate-Specific Antigen Bounce After High-Dose-Rate Monotherapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Mehta, Niraj H., E-mail: nmehta@mednet.ucla.edu [University of California, Los Angeles, Los Angeles, California (United States); Kamrava, Mitchell; Wang, Pin-Chieh; Steinberg, Michael; Demanes, Jeffrey [University of California, Los Angeles, Los Angeles, California (United States)

    2013-07-15

    Purpose: To characterize the magnitude and kinetics of prostate-specific antigen (PSA) bounces after high-dose-rate (HDR) monotherapy and determine relationships between certain clinical factors and PSA bounce. Methods and Materials: Longitudinal PSA data and various clinical parameters were examined in 157 consecutive patients treated with HDR monotherapy between 1996 and 2005. We used the following definition for PSA bounce: rise in PSA ≥threshold, after which it returns to the prior level or lower. Prostate-specific antigen failure was defined per the Phoenix definition (nadir +2 ng/mL). Results: A PSA bounce was noted in 67 patients (43%). The number of bounces per patient was 1 in 45 cases (67%), 2 in 19 (28%), 3 in 2 (3%), 4 in 0, and 5 in 1 (1%). The median time to maximum PSA bounce was 1.3 years, its median magnitude was 0.7, and its median duration was 0.75 years. Three patients (2%) were noted to have PSA failure. None of the 3 patients who experienced biochemical failure exhibited PSA bounce. In the fully adjusted model for predicting each bounce, patients aged <55 years had a statistically significant higher likelihood of experiencing a bounce (odds ratio 2.22, 95% confidence interval 1.38-3.57, P=.001). There was also a statistically significant higher probability of experiencing a bounce for every unit decrease in Gleason score (odds ratio 1.52, 95% confidence interval 1.01-2.04, P=.045). Conclusions: A PSA bounce occurs in a significant percentage of patients treated with HDR monotherapy, with magnitudes varying from <1 in 28% of cases to ≥1 in 15%. The median duration of bounce is <1 year. More bounces were identified in patients with lower Gleason score and age <55 years. Further investigation using a model to correlate magnitude and frequency of bounces with clinical variables are under way.

  13. Online pretreatment verification of high-dose rate brachytherapy using an imaging panel

    Science.gov (United States)

    Fonseca, Gabriel P.; Podesta, Mark; Bellezzo, Murillo; Van den Bosch, Michiel R.; Lutgens, Ludy; Vanneste, Ben G. L.; Voncken, Robert; Van Limbergen, Evert J.; Reniers, Brigitte; Verhaegen, Frank

    2017-07-01

    Brachytherapy is employed to treat a wide variety of cancers. However, an accurate treatment verification method is currently not available. This study describes a pre-treatment verification system that uses an imaging panel (IP) to verify important aspects of the treatment plan. A detailed modelling of the IP was only possible with an extensive calibration performed using a robotic arm. Irradiations were performed with a high dose rate (HDR) 192Ir source within a water phantom. An empirical fit was applied to measure the distance between the source and the detector so 3D Cartesian coordinates of the dwell positions can be obtained using a single panel. The IP acquires 7.14 fps to verify the dwell times, dwell positions and air kerma strength (Sk). A gynecological applicator was used to create a treatment plan that was registered with a CT image of the water phantom used during the experiments for verification purposes. Errors (shifts, exchanged connections and wrong dwell times) were simulated to verify the proposed verification system. Cartesian source positions (panel measurement plane) have a standard deviation of about 0.02 cm. The measured distance between the source and the panel (z-coordinate) have a standard deviation up to 0.16 cm and maximum absolute error of  ≈0.6 cm if the signal is close to sensitive limit of the panel. The average response of the panel is very linear with Sk. Therefore, Sk measurements can be performed with relatively small errors. The measured dwell times show a maximum error of 0.2 s which is consistent with the acquisition rate of the panel. All simulated errors were clearly identified by the proposed system. The use of IPs is not common in brachytherapy, however, it provides considerable advantages. It was demonstrated that the IP can accurately measure Sk, dwell times and dwell positions.

  14. Dosimetric evaluation of two treatment planning systems for high dose rate brachytherapy applications.

    Science.gov (United States)

    Shwetha, Bondel; Ravikumar, Manickam; Supe, Sanjay S; Sathiyan, Saminathan; Lokesh, Vishwanath; Keshava, Subbarao L

    2012-01-01

    Various treatment planning systems are used to design plans for the treatment of cervical cancer using high-dose-rate brachytherapy. The purpose of this study was to make a dosimetric comparison of the 2 treatment planning systems from Varian medical systems, namely ABACUS and BrachyVision. The dose distribution of Ir-192 source generated with a single dwell position was compared using ABACUS (version 3.1) and BrachyVision (version 6.5) planning systems. Ten patients with intracavitary applications were planned on both systems using orthogonal radiographs. Doses were calculated at the prescription points (point A, right and left) and reference points RU, LU, RM, LM, bladder, and rectum. For single dwell position, little difference was observed in the doses to points along the perpendicular bisector. The mean difference between ABACUS and BrachyVision for these points was 1.88%. The mean difference in the dose calculated toward the distal end of the cable by ABACUS and BrachyVision was 3.78%, whereas along the proximal end the difference was 19.82%. For the patient case there was approximately 2% difference between ABACUS and BrachyVision planning for dose to the prescription points. The dose difference for the reference points ranged from 0.4-1.5%. For bladder and rectum, the differences were 5.2% and 13.5%, respectively. The dose difference between the rectum points was statistically significant. There is considerable difference between the dose calculations performed by the 2 treatment planning systems. It is seen that these discrepancies are caused by the differences in the calculation methodology adopted by the 2 systems.

  15. 3D-printed surface mould applicator for high-dose-rate brachytherapy

    Science.gov (United States)

    Schumacher, Mark; Lasso, Andras; Cumming, Ian; Rankin, Adam; Falkson, Conrad B.; Schreiner, L. John; Joshi, Chandra; Fichtinger, Gabor

    2015-03-01

    In contemporary high-dose-rate brachytherapy treatment of superficial tumors, catheters are placed in a wax mould. The creation of current wax models is a difficult and time consuming proces.The irradiation plan can only be computed post-construction and requires a second CT scan. In case no satisfactory dose plan can be created, the mould is discarded and the process is repeated. The objective of this work was to develop an automated method to replace suboptimal wax moulding. We developed a method to design and manufacture moulds that guarantee to yield satisfactory dosimetry. A 3D-printed mould with channels for the catheters designed from the patient's CT and mounted on a patient-specific thermoplastic mesh mask. The mould planner was implemented as an open-source module in the 3D Slicer platform. Series of test moulds were created to accommodate standard brachytherapy catheters of 1.70mm diameter. A calibration object was used to conclude that tunnels with a diameter of 2.25mm, minimum 12mm radius of curvature, and 1.0mm open channel gave the best fit for this printer/catheter combination. Moulds were created from the CT scan of thermoplastic mesh masks of actual patients. The patient-specific moulds have been visually verified to fit on the thermoplastic meshes. The masks were visually shown to fit onto the thermoplastic meshes, next the resulting dosimetry will have to be compared with treatment plans and dosimetry achieved with conventional wax moulds in order to validate our 3D printed moulds.

  16. High-Dose-Rate Brachytherapy Boost for Prostate Cancer: Comparison of Two Different Fractionation Schemes

    Energy Technology Data Exchange (ETDEWEB)

    Kaprealian, Tania [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Weinberg, Vivian [Biostatistics and Computational Biology Core, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Speight, Joycelyn L. [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Department of Urology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Gottschalk, Alexander R. [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Roach, Mack [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Department of Urology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Shinohara, Katsuto [Department of Urology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Hsu, I.-Chow, E-mail: IHsu@radonc.ucsf.edu [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States)

    2012-01-01

    Purpose: This is a retrospective study comparing our experience with high-dose-rate (HDR) brachytherapy boost for prostate cancer, using two different fractionation schemes, 600 cGy Multiplication-Sign 3 fractions (patient group 1) and 950 cGy Multiplication-Sign 2 fractions (patient group 2). Methods and Materials: A total of 165 patients were treated for prostate cancer using external beam radiation therapy up to a dose of 45 Gy, followed by an HDR brachytherapy prostate radiation boost. Between July 1997 and Nov 1999, 64 patients were treated with an HDR boost of 600 cGy Multiplication-Sign 3 fractions; and between June 2000 and Nov 2005, 101 patients were treated with an HDR boost of 950 cGy Multiplication-Sign 2 fractions. All but 9 patients had at least one of the following risk features: pretreatment prostate-specific antigen (PSA) level >10, a Gleason score {>=}7, and/or clinical stage T3 disease. Results: Median follow-up was 105 months for group 1 and 43 months for group 2. Patients in group 2 had a greater number of high-risk features than group 1 (p = 0.02). Adjusted for comparable follow-up, there was no difference in biochemical no-evidence-of-disease (bNED) rate between the two fractionation scheme approaches, with 5-year Kaplan-Meier estimates of 93.5% in group 1 and 87.3% in group 2 (p = 0.19). The 5-year estimates of progression-free survival were 86% for group 1 and 83% for group 2 (p = 0.53). Among high-risk patients, there were no differences in bNED or PFS rate due to fractionation. Conclusions: Results were excellent for both groups. Adjusted for comparable follow-up, no differences were found between groups.

  17. Robustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements.

    Science.gov (United States)

    Poder, Joel; Whitaker, May

    2016-06-01

    Inverse planning simulated annealing (IPSA) optimized brachytherapy treatment plans are characterized with large isolated dwell times at the first or last dwell position of each catheter. The potential of catheter shifts relative to the target and organs at risk in these plans may lead to a more significant change in delivered dose to the volumes of interest relative to plans with more uniform dwell times. This study aims to determine if the Nucletron Oncentra dwell time deviation constraint (DTDC) parameter can be optimized to improve the robustness of high-dose-rate (HDR) prostate brachytherapy plans to catheter displacements. A set of 10 clinically acceptable prostate plans were re-optimized with a DTDC parameter of 0 and 0.4. For each plan, catheter displacements of 3, 7, and 14 mm were retrospectively applied and the change in dose volume histogram (DVH) indices and conformity indices analyzed. The robustness of clinically acceptable prostate plans to catheter displacements in the caudal direction was found to be dependent on the DTDC parameter. A DTDC value of 0 improves the robustness of planning target volume (PTV) coverage to catheter displacements, whereas a DTDC value of 0.4 improves the robustness of the plans to changes in hotspots. The results indicate that if used in conjunction with a pre-treatment catheter displacement correction protocol and a tolerance of 3 mm, a DTDC value of 0.4 may produce clinically superior plans. However, the effect of the DTDC parameter in plan robustness was not observed to be as strong as initially suspected.

  18. Dosimetry audits in Brazil for {sup 192}Ir high dose rate brachytherapy systems

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, L.A.R. da; Paiva, E. de.; Goncalves, M.G.; Velasco, A.F.; Di Prinzio, R.; Dovales, A.C.M.; Freire, B.L.V.; Brito, R.R.A.; Giannoni, R.A.; Castelo, L.H.R. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Marechal, M.H.H. [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil). Coordenacao de Instalacoes Radiativas (CORAD)

    2005-03-15

    In Brazil, among 200 radiotherapy centres, 30 have high dose rate (HDR) {sup 192}Ir brachytherapy systems. In August 2001, the Brazilian National Nuclear Energy Commission (CNEN) started a biennial audit program to those centres having HDR systems. This program consists of visiting each centre in order to investigate the radiation protection aspects of the centres and also to measure the intensity of the brachytherapy source, in terms of air kerma strength, with a well type chamber specially designed for HDR {sup 192} Ir sources. The audit dosimetry results are compared to measurements carried out by the local institution physicist and to the source intensity value provided by the manufacturer. Two methods have been used by the Brazilian physicists for HDR {sup 192}Ir brachytherapy source dosimetry, namely the employment of a farmer type chamber calibrated according to the interpolation methodology and the use of a well type chamber to provide direct intercomparison. The larger difference obtained was 18.9% and it can be explained in terms of the lack of knowledge of the institution physicist about the interpolation methodology using the farmer type chamber. Another difference of 5.82% was found as being the lack of an updated calibration factor for the clinic well type chamber. On the basis of these results, CNEN is able to establish a maximum deviation value for the dosimetry of HDR system. Additionally, with this program the radiotherapy services have an opportunity to have their HDR {sup 192}Ir sources calibrated and to test the validity of the calibration factors for their own well type chambers, using their calibrated sources. (author)

  19. Automated high-dose rate brachytherapy treatment planning for a single-channel vaginal cylinder applicator

    Science.gov (United States)

    Zhou, Yuhong; Klages, Peter; Tan, Jun; Chi, Yujie; Stojadinovic, Strahinja; Yang, Ming; Hrycushko, Brian; Medin, Paul; Pompos, Arnold; Jiang, Steve; Albuquerque, Kevin; Jia, Xun

    2017-06-01

    High dose rate (HDR) brachytherapy treatment planning is conventionally performed manually and/or with aids of preplanned templates. In general, the standard of care would be elevated by conducting an automated process to improve treatment planning efficiency, eliminate human error, and reduce plan quality variations. Thus, our group is developing AutoBrachy, an automated HDR brachytherapy planning suite of modules used to augment a clinical treatment planning system. This paper describes our proof-of-concept module for vaginal cylinder HDR planning that has been fully developed. After a patient CT scan is acquired, the cylinder applicator is automatically segmented using image-processing techniques. The target CTV is generated based on physician-specified treatment depth and length. Locations of the dose calculation point, apex point and vaginal surface point, as well as the central applicator channel coordinates, and the corresponding dwell positions are determined according to their geometric relationship with the applicator and written to a structure file. Dwell times are computed through iterative quadratic optimization techniques. The planning information is then transferred to the treatment planning system through a DICOM-RT interface. The entire process was tested for nine patients. The AutoBrachy cylindrical applicator module was able to generate treatment plans for these cases with clinical grade quality. Computation times varied between 1 and 3 min on an Intel Xeon CPU E3-1226 v3 processor. All geometric components in the automated treatment plans were generated accurately. The applicator channel tip positions agreed with the manually identified positions with submillimeter deviations and the channel orientations between the plans agreed within less than 1 degree. The automatically generated plans obtained clinically acceptable quality.

  20. Brachytherapy for early oral tongue cancer: low dose rate to high dose rate.

    Science.gov (United States)

    Yamazaki, Hideya; Inoue, Takehiro; Yoshida, Ken; Yoshioka, Yasuo; Furukawa, Souhei; Kakimoto, Naoya; Shimizutani, Kimishige; Inoue, Toshihiko

    2003-03-01

    To examine the compatibility of low dose rate (LDR) with high dose rate (HDR) brachytherapy, we reviewed 399 patients with early oral tongue cancer (T1-2N0M0) treated solely by brachytherapy at Osaka University Hospital between 1967 and 1999. For patients in the LDR group (n = 341), the treatment sources consisted of Ir-192 pin for 227 patients (1973-1996; irradiated dose, 61-85 Gy; median, 70 Gy), Ra-226 needle for 113 patients (1967-1986; 55-93 Gy; median, 70 Gy). Ra-226 and Ir-192 were combined for one patient. Ir-192 HDR (microSelectron-HDR) was used for 58 patients in the HDR group (1991-present; 48-60 Gy; median, 60 Gy). LDR implantations were performed via oral and HDR via a submental/submandibular approach. The dose rates at the reference point for the LDR group were 0.30 to 0.8 Gy/h, and for the HDR group 1.0 to 3.4 Gy/min. The patients in the HDR group received a total dose of 48-60 Gy (8-10 fractions) during one week. Two fractions were administered per day (at least a 6-h interval). The 3- and 5-year local control rates for patients in the LDR group were 85% and 80%, respectively, and those in the HDR group were both 84%. HDR brachytherapy showed the same lymph-node control rate as did LDR brachytherapy (67% at 5 years). HDR brachytherapy achieved the same locoregional result as did LDR brachytherapy. A converting factor of 0.86 is applicable for HDR in the treatment of early oral tongue cancer.

  1. Dosimetric comparison between three dimensional treatment planning system, Monte Carlo simulation and gel dosimetry in nasopharynx phantom for high dose rate brachytherapy

    Directory of Open Access Journals (Sweden)

    Zeynab Fazli

    2013-01-01

    Full Text Available Purpose: For the treatment of nasopharnx carcinoma (NPC using brachytherapy methods and high-energy photon sources are common techniques. In the common three dimensional (3D treatments planning, all of the computed tomography images are assumed homogeneous. This study presents the results of Monte Carlo calculations for non-homogeneous nasopharynx phantom, MAGICA normoxic gel dosimetry and 3D treatment planning system (TPS. Materials and Methods: The head phantom was designed with Plexiglas cylinder, head bone, and nasopharynx brachytherapy silicon applicator. For the simulations, version 5 of the Monte Carlo N-particle transport code (MCNP5 was used. 3D treatment planning was performed in Flexiplan software. A normoxic radiosensitive polymer gel was fabricated under normal atmospheric conditions and poured into test tubes (for calibration curve and the head phantom. In addition, the head phantom was irradiated with Flexitron afterloader brachytherapy machine with 192 Ir source. To obtain calibration curves, 11 dosimeters were irradiated with dose range of 0-2000 cGy. Evaluations of dosimeters were performed on 1.5T scanner. Results: Two-dimensional iso-dose in coronal plan at distances of z = +0.3, –0.3 cm was calculated. There was a good accordance between 3D TPS and MCNP5 simulation and differences in various distances were between 2.4% and 6.1%. There was a predictable accordance between MAGICA gel dosimetry and MCNP5 simulation and differences in various distances were between 5.7% and 7.4%. Moreover, there was an acceptable accordance between MAGICA gel dosimetry and MCNP5 data and differences in various distances were between 5.2% and 9.4%. Conclusion: The sources of differences in this comparison are divided to calculations variation and practical errors that was added in experimental dosimetry. The result of quality assurance of nasopharynx high dose rate brachytherapy is consistent with international standards.

  2. Dosimetric comparison between three dimensional treatment planning system, Monte Carlo simulation and gel dosimetry in nasopharynx phantom for high dose rate brachytherapy.

    Science.gov (United States)

    Fazli, Zeynab; Sadeghi, Mahdi; Zahmatkesh, M H; Mahdavi, Seied Rabei; Tenreiro, Claudio

    2013-01-01

    For the treatment of nasopharnx carcinoma (NPC) using brachytherapy methods and high-energy photon sources are common techniques. In the common three dimensional (3D) treatments planning, all of the computed tomography images are assumed homogeneous. This study presents the results of Monte Carlo calculations for non-homogeneous nasopharynx phantom, MAGICA normoxic gel dosimetry and 3D treatment planning system (TPS). The head phantom was designed with Plexiglas cylinder, head bone, and nasopharynx brachytherapy silicon applicator. For the simulations, version 5 of the Monte Carlo N-particle transport code (MCNP5) was used. 3D treatment planning was performed in Flexiplan software. A normoxic radiosensitive polymer gel was fabricated under normal atmospheric conditions and poured into test tubes (for calibration curve) and the head phantom. In addition, the head phantom was irradiated with Flexitron afterloader brachytherapy machine with (192)Ir source. To obtain calibration curves, 11 dosimeters were irradiated with dose range of 0-2000 cGy. Evaluations of dosimeters were performed on 1.5T scanner. Two-dimensional iso-dose in coronal plan at distances of z = +0.3, -0.3 cm was calculated. There was a good accordance between 3D TPS and MCNP5 simulation and differences in various distances were between 2.4% and 6.1%. There was a predictable accordance between MAGICA gel dosimetry and MCNP5 simulation and differences in various distances were between 5.7% and 7.4%. Moreover, there was an acceptable accordance between MAGICA gel dosimetry and MCNP5 data and differences in various distances were between 5.2% and 9.4%. The sources of differences in this comparison are divided to calculations variation and practical errors that was added in experimental dosimetry. The result of quality assurance of nasopharynx high dose rate brachytherapy is consistent with international standards.

  3. Monte Carlo study of radiation dose enhancement by gadolinium in megavoltage and high dose rate radiotherapy.

    Directory of Open Access Journals (Sweden)

    Daniel G Zhang

    Full Text Available MRI is often used in tumor localization for radiotherapy treatment planning, with gadolinium (Gd-containing materials often introduced as a contrast agent. Motexafin gadolinium is a novel radiosensitizer currently being studied in clinical trials. The nanoparticle technologies can target tumors with high concentration of high-Z materials. This Monte Carlo study is the first detailed quantitative investigation of high-Z material Gd-induced dose enhancement in megavoltage external beam photon therapy. BEAMnrc, a radiotherapy Monte Carlo simulation package, was used to calculate dose enhancement as a function of Gd concentration. Published phase space files for the TrueBeam flattening filter free (FFF and conventional flattened 6MV photon beams were used. High dose rate (HDR brachytherapy with Ir-192 source was also investigated as a reference. The energy spectra difference caused a dose enhancement difference between the two beams. Since the Ir-192 photons have lower energy yet, the photoelectric effect in the presence of Gd leads to even higher dose enhancement in HDR. At depth of 1.8 cm, the percent mean dose enhancement for the FFF beam was 0.38±0.12, 1.39±0.21, 2.51±0.34, 3.59±0.26, and 4.59±0.34 for Gd concentrations of 1, 5, 10, 15, and 20 mg/mL, respectively. The corresponding values for the flattened beam were 0.09±0.14, 0.50±0.28, 1.19±0.29, 1.68±0.39, and 2.34±0.24. For Ir-192 with direct contact, the enhanced were 0.50±0.14, 2.79±0.17, 5.49±0.12, 8.19±0.14, and 10.80±0.13. Gd-containing materials used in MRI as contrast agents can also potentially serve as radiosensitizers in radiotherapy. This study demonstrates that Gd can be used to enhance radiation dose in target volumes not only in HDR brachytherapy, but also in 6 MV FFF external beam radiotherapy, but higher than the currently used clinical concentration (>5 mg/mL would be needed.

  4. Direction-Modulated Brachytherapy for High-Dose-Rate Treatment of Cervical Cancer. I: Theoretical Design

    Energy Technology Data Exchange (ETDEWEB)

    Han, Dae Yup [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, California (United States); Webster, Matthew J. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Department of Physics, University of California San Diego, La Jolla, California (United States); Scanderbeg, Daniel J.; Yashar, Catheryn; Choi, Dongju; Song, Bongyong [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Devic, Slobodan [Medical Physics Unit, McGill University, Montréal, Québec (Canada); Department of Radiation Oncology, Jewish General Hospital, Montréal, Québec (Canada); Ravi, Ananth [Department of Medical Physics, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Song, William Y., E-mail: wyjsong@gmail.com [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Department of Medical Physics, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada)

    2014-07-01

    Purpose: To demonstrate that utilization of the direction-modulated brachytherapy (DMBT) concept can significantly improve treatment plan quality in the setting of high-dose-rate (HDR) brachytherapy for cervical cancer. Methods and Materials: The new, MRI-compatible, tandem design has 6 peripheral holes of 1.3-mm diameter, grooved along a nonmagnetic tungsten-alloy rod (ρ = 18.0 g/cm{sup 3}), enclosed in Delrin tubing (polyoxymethylene, ρ = 1.41 g/cm{sup 3}), with a total thickness of 6.4 mm. The Monte Carlo N-Particle code was used to calculate the anisotropic {sup 192}Ir dose distributions. An in-house-developed inverse planning platform, geared with simulated annealing and constrained-gradient optimization algorithms, was used to replan 15 patient cases (total 75 plans) treated with a conventional tandem and ovoids (T and O) applicator. Prescription dose was 6 Gy. For replanning, we replaced the conventional tandem with that of the new DMBT tandem for optimization but left the ovoids in place and kept the dwell positions as originally planned. All DMBT plans were normalized to match the high-risk clinical target volume V100 coverage of the T and O plans. Results: In general there were marked improvements in plan quality for the DMBT plans. On average, D2cc for the bladder, rectum, and sigmoid were reduced by 0.59 ± 0.87 Gy (8.5% ± 28.7%), 0.48 ± 0.55 Gy (21.1% ± 27.2%), and 0.10 ± 0.38 Gy (40.6% ± 214.9%) among the 75 plans, with best single-plan reductions of 3.20 Gy (40.8%), 2.38 Gy (40.07%), and 1.26 Gy (27.5%), respectively. The high-risk clinical target volume D90 was similar, with 6.55 ± 0.96 Gy and 6.59 ± 1.06 Gy for T and O and DMBT, respectively. Conclusions: Application of the DMBT concept to cervical cancer allowed for improved organ at risk sparing while achieving similar target coverage on a sizeable patient population, as intended, by maximally utilizing the anatomic information contained in 3-dimensional

  5. Patient-specific dose calculation methods for high-dose-rate iridium-192 brachytherapy

    Science.gov (United States)

    Poon, Emily S.

    In high-dose-rate 192Ir brachytherapy, the radiation dose received by the patient is calculated according to the AAPM Task Group 43 (TG-43) formalism. This table-based dose superposition method uses dosimetry parameters derived with the radioactive 192Ir source centered in a water phantom. It neglects the dose perturbations caused by inhomogeneities, such as the patient anatomy, applicators, shielding, and radiographic contrast solution. In this work, we evaluated the dosimetric characteristics of a shielded rectal applicator with an endocavitary balloon injected with contrast solution. The dose distributions around this applicator were calculated by the GEANT4 Monte Carlo (MC) code and measured by ionization chamber and GAFCHROMIC EBT film. A patient-specific dose calculation study was then carried out for 40 rectal treatment plans. The PTRAN_CT MC code was used to calculate the dose based on computed tomography (CT) images. This study involved the development of BrachyGUI, an integrated treatment planning tool that can process DICOM-RT data and create PTRAN_CT input initialization files. BrachyGUI also comes with dose calculation and evaluation capabilities. We proposed a novel scatter correction method to account for the reduction in backscatter radiation near tissue-air interfaces. The first step requires calculating the doses contributed by primary and scattered photons separately, assuming a full scatter environment. The scatter dose in the patient is subsequently adjusted using a factor derived by MC calculations, which depends on the distances between the point of interest, the 192Ir source, and the body contour. The method was validated for multicatheter breast brachytherapy, in which the target and skin doses for 18 patient plans agreed with PTRAN_CT calculations better than 1%. Finally, we developed a CT-based analytical dose calculation method. It corrects for the photon attenuation and scatter based upon the radiological paths determined by ray tracing

  6. Definitive three-dimensional high-dose-rate brachytherapy for inoperable endometrial cancer

    Science.gov (United States)

    Draghini, Lorena; Casale, Michelina; Trippa, Fabio; Anselmo, Paola; Arcidiacono, Fabio; Fabiani, Stefania; Italiani, Marco; Chirico, Luigia; Muti, Marco

    2017-01-01

    Purpose To report our experience on high-dose-rate brachytherapy (HDR-BT) in patients with stage I-III endometrial cancer unfit to surgery. Material and methods Seventeen patients underwent HDR-BT as definitive treatment. Median age was 79 years (range, 60-95), median Karnofsky performance status 90% (range, 60-100). Histology was endometrial adenocarcinoma in 14 (82%), and non-endometrial in 3 (18%) patients. In 15 (88%) patients, clinical stage was I and in remaining 2 (12%) was III. All patients were evaluated with computed tomography (CT) and endometrial biopsy. Using the Fletcher applicator, a CT-based planning HDR-BT was delivered. Local control (LC) was obtained when there was an interruption of vaginal bleeding in absence of CT-imaging progression. Results Fourteen patients underwent HDR-BT alone and three external beam radiotherapy (EBRT) combined with HDR-BT. All patients had a clinical LC, after a median follow-up of 53 months (range, 6-131), 3 and 6 years LC rates were 86% and 69%, respectively. Cancer specific survival (CSS) at 1, 2, and 6 years was 93%, 85%, and 85%, respectively. Age, stage, dose, and type of radiotherapy did not result significant prognostic factors for LC and CSS. Only histology significantly influenced LC: for high-risk histology (i.e., non-endometrial carcinoma or grade [G] 3 endometrial adenocarcinoma) LC was 73% at 1 year and 36% at 6 years; for low-risk histology (i.e., G1-2 endometrial adenocarcinoma) was 100% at 1 and 6 years (p = 0.05). Two (12%) patients had G2 acute toxicity and two others (12%) G1 late toxicity. Conclusions Although some limitations of our analysis (relatively few number of patients recruited, retrospective evaluation, and consequent suboptimal patient selection), it confirms effectiveness and safety of definitive HDR-BT for medically inoperable stage I-III endometrial cancer. The best LC was obtained in stage I low-risk histology. PMID:28533799

  7. Definitive three-dimensional high-dose-rate brachytherapy for inoperable endometrial cancer

    Directory of Open Access Journals (Sweden)

    Lorena Draghini

    2017-04-01

    Full Text Available Purpose : To report our experience on high-dose-rate brachytherapy (HDR-BT in patients with stage I-III endometrial cancer unfit to surgery. Material and methods : Seventeen patients underwent HDR-BT as definitive treatment. Median age was 79 years (range, 60-95, median Karnofsky performance status 90% (range, 60-100. Histology was endometrial adenocarcinoma in 14 (82%, and non-endometrial in 3 (18% patients. In 15 (88% patients, clinical stage was I and in remaining 2 (12% was III. All patients were evaluated with computed tomography (CT and endometrial biopsy. Using the Fletcher applicator, a CT-based planning HDR-BT was delivered. Local control (LC was obtained when there was an interruption of vaginal bleeding in absence of CT-imaging progression. Results : Fourteen patients underwent HDR-BT alone and three external beam radiotherapy (EBRT combined with HDR-BT. All patients had a clinical LC, after a median follow-up of 53 months (range, 6-131, 3 and 6 years LC rates were 86% and 69%, respectively. Cancer specific survival (CSS at 1, 2, and 6 years was 93%, 85%, and 85%, respectively. Age, stage, dose, and type of radiotherapy did not result significant prognostic factors for LC and CSS. Only histology significantly influenced LC: for high-risk histology (i.e., non-endometrial carcinoma or grade [G] 3 endometrial adeno­carcinoma LC was 73% at 1 year and 36% at 6 years; for low-risk histology (i.e., G1-2 endometrial adenocarcinoma was 100% at 1 and 6 years (p = 0.05. Two (12% patients had G2 acute toxicity and two others (12% G1 late toxicity. Conclusions : Although some limitations of our analysis (relatively few number of patients recruited, retrospective evaluation, and consequent suboptimal patient selection, it confirms effectiveness and safety of definitive HDR-BT for medically inoperable stage I-III endometrial cancer. The best LC was obtained in stage I low-risk histology.

  8. Performance assessment of the BEBIG MultiSource high dose rate brachytherapy treatment unit.

    Science.gov (United States)

    Palmer, Antony; Mzenda, Bongile

    2009-12-21

    A comprehensive system characterisation was performed of the Eckert & Ziegler BEBIG GmbH MultiSource High Dose Rate (HDR) brachytherapy treatment unit with an (192)Ir source. The unit is relatively new to the UK market, with the first installation in the country having been made in the summer of 2009. A detailed commissioning programme was devised and is reported including checks of the fundamental parameters of source positioning, dwell timing, transit doses and absolute dosimetry of the source. Well chamber measurements, autoradiography and video camera analysis techniques were all employed. The absolute dosimetry was verified by the National Physical Laboratory, UK, and compared to a measurement based on a calibration from PTB, Germany, and the supplied source certificate, as well as an independent assessment by a visiting UK centre. The use of the 'Krieger' dosimetry phantom has also been evaluated. Users of the BEBIG HDR system should take care to avoid any significant bend in the transfer tube, as this will lead to positioning errors of the source, of up to 1.0 mm for slight bends, 2.0 mm for moderate bends and 5.0 mm for extreme curvature (depending on applicators and transfer tube used) for the situations reported in this study. The reason for these errors and the potential clinical impact are discussed. Users should also note the methodology employed by the system for correction of transit doses, and that no correction is made for the initial and final transit doses. The results of this investigation found that the uncorrected transit doses lead to small errors in the delivered dose at the first dwell position, of up to 2.5 cGy at 2 cm (5.6 cGy at 1 cm) from a 10 Ci source, but the transit dose correction for other dwells was accurate within 0.2 cGy. The unit has been mechanically reliable, and source positioning accuracy and dwell timing have been reproducible, with overall performance similar to other existing HDR equipment. The unit is capable of high

  9. Monte Carlo study of radiation dose enhancement by gadolinium in megavoltage and high dose rate radiotherapy.

    Science.gov (United States)

    Zhang, Daniel G; Feygelman, Vladimir; Moros, Eduardo G; Latifi, Kujtim; Zhang, Geoffrey G

    2014-01-01

    MRI is often used in tumor localization for radiotherapy treatment planning, with gadolinium (Gd)-containing materials often introduced as a contrast agent. Motexafin gadolinium is a novel radiosensitizer currently being studied in clinical trials. The nanoparticle technologies can target tumors with high concentration of high-Z materials. This Monte Carlo study is the first detailed quantitative investigation of high-Z material Gd-induced dose enhancement in megavoltage external beam photon therapy. BEAMnrc, a radiotherapy Monte Carlo simulation package, was used to calculate dose enhancement as a function of Gd concentration. Published phase space files for the TrueBeam flattening filter free (FFF) and conventional flattened 6MV photon beams were used. High dose rate (HDR) brachytherapy with Ir-192 source was also investigated as a reference. The energy spectra difference caused a dose enhancement difference between the two beams. Since the Ir-192 photons have lower energy yet, the photoelectric effect in the presence of Gd leads to even higher dose enhancement in HDR. At depth of 1.8 cm, the percent mean dose enhancement for the FFF beam was 0.38±0.12, 1.39±0.21, 2.51±0.34, 3.59±0.26, and 4.59±0.34 for Gd concentrations of 1, 5, 10, 15, and 20 mg/mL, respectively. The corresponding values for the flattened beam were 0.09±0.14, 0.50±0.28, 1.19±0.29, 1.68±0.39, and 2.34±0.24. For Ir-192 with direct contact, the enhanced were 0.50±0.14, 2.79±0.17, 5.49±0.12, 8.19±0.14, and 10.80±0.13. Gd-containing materials used in MRI as contrast agents can also potentially serve as radiosensitizers in radiotherapy. This study demonstrates that Gd can be used to enhance radiation dose in target volumes not only in HDR brachytherapy, but also in 6 MV FFF external beam radiotherapy, but higher than the currently used clinical concentration (>5 mg/mL) would be needed.

  10. Inverse Planned High-Dose-Rate Brachytherapy for Locoregionally Advanced Cervical Cancer: 4-Year Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Tinkle, Christopher L.; Weinberg, Vivian [Department of Radiation Oncology, University of California, San Francisco, California (United States); Chen, Lee-May [Department of Obstetrics, Gynecology, and Reproductive Sciences, University of California, San Francisco, California (United States); Littell, Ramey [Gynecologic Oncology, The Permanente Medical Group, San Francisco, California (United States); Cunha, J. Adam M.; Sethi, Rajni A. [Department of Radiation Oncology, University of California, San Francisco, California (United States); Chan, John K. [Gynecologic Oncology, California Pacific Medical Center, San Francisco, California (United States); Hsu, I-Chow, E-mail: ichow.hsu@ucsf.edu [Department of Radiation Oncology, University of California, San Francisco, California (United States)

    2015-08-01

    Purpose: Evaluate the efficacy and toxicity of image guided brachytherapy using inverse planning simulated annealing (IPSA) high-dose-rate brachytherapy (HDRB) boost for locoregionally advanced cervical cancer. Methods and Materials: From December 2003 through September 2009, 111 patients with primary cervical cancer were treated definitively with IPSA-planned HDRB boost (28 Gy in 4 fractions) after external radiation at our institution. We performed a retrospective review of our experience using image guided brachytherapy. Of the patients, 70% had a tumor size >4 cm, 38% had regional nodal disease, and 15% had clinically evident distant metastasis, including nonregional nodal disease, at the time of diagnosis. Surgical staging involving pelvic lymph node dissection was performed in 15% of patients, and 93% received concurrent cisplatin-based chemotherapy. Toxicities are reported according to the Common Terminology Criteria for Adverse Events version 4.0 guidelines. Results: With a median follow-up time of 42 months (range, 3-84 months), no acute or late toxicities of grade 4 or higher were observed, and grade 3 toxicities (both acute and late) developed in 8 patients (1 constitutional, 1 hematologic, 2 genitourinary, 4 gastrointestinal). The 4-year Kaplan-Meier estimate of late grade 3 toxicity was 8%. Local recurrence developed in 5 patients (4 to 9 months after HDRB), regional recurrence in 3 (6, 16, and 72 months after HDRB), and locoregional recurrence in 1 (4 months after HDR boost). The 4-year estimates of local, locoregional, and distant control of disease were 94.0%, 91.9%, and 69.1%, respectively. The overall and disease-free survival rates at 4 years were 64.3% (95% confidence interval [CI] of 54%-73%) and 61.0% (95% CI, 51%-70%), respectively. Conclusions: Definitive radiation by use of inverse planned HDRB boost for locoregionally advanced cervical cancer is well tolerated and achieves excellent local control of disease. However, overall

  11. Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Y. Sobita Devi

    2011-12-01

    Full Text Available Purpose: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation withlocal/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate(HDR brachytherapy (BT source is reduced to single, double and triple half life in relation to original strength of10 Ci (~ 4.081 cGy x m2 x h–1. Material and methods: A retrospective study was carried out on 52 cervical cancer patients with stage II and IIItreated with fractionated HDR-BT following external beam radiation therapy (EBRT. International Commission onRadiation Units and Measurement (ICRU points were defined according to ICRU Report 38, using two orthogonal radiographimages taken by Simulator (Simulix HQ. Biologically effective dose (BED was calculated at point A for diffe -rent Ir-192 source strength and its possible correlation with local/loco-regional tumour control was discussed. Result: The increase of treatment time per fraction of dose due to the fall of dose rate especially in HDR-BT of cervicalcancer results in reduction in BED of 2.59%, 7.02% and 13.68% with single, double and triple half life reduction ofsource strength, respectively. The probabilities of disease recurrence (local/loco-regional within 26 months are expectedas 0.12, 0.12, 0.16, 0.39 and 0.80 for source strength of 4.081, 2.041, 1.020, 0.510 and 0.347 cGy x m2 x h–1, respectively.The percentages of dose increase required to maintain the same BED with respect to initial BED were estimated as1.71, 5.00, 11.00 and 15.86 for the dose rate of 24.7, 12.4, 6.2 and 4.2 Gy/hr at point A, respectively. Conclusions: This retrospective study of cervical cancer patients treated with HDR-BT at different Ir-192 sourcestrength shows reduction in disease free survival according to the increase in treatment time duration per fraction.The probable result could be associated with the decrease of biological equivalent dose to point A. Clinical

  12. Predictors of Toxicity After Image-guided High-dose-rate Interstitial Brachytherapy for Gynecologic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Larissa J. [Department of Radiation Oncology, Brigham and Women' s Hospital and Dana-Farber Cancer Institute, Harvard Medical School, Boston, Massachusetts (United States); Viswanathan, Akila N., E-mail: aviswanathan@lroc.harvard.edu [Department of Radiation Oncology, Brigham and Women' s Hospital and Dana-Farber Cancer Institute, Harvard Medical School, Boston, Massachusetts (United States)

    2012-12-01

    Purpose: To identify predictors of grade 3-4 complications and grade 2-4 rectal toxicity after three-dimensional image-guided high-dose-rate (HDR) interstitial brachytherapy for gynecologic cancer. Methods and Materials: Records were reviewed for 51 women (22 with primary disease and 29 with recurrence) treated with HDR interstitial brachytherapy. A single interstitial insertion was performed with image guidance by computed tomography (n = 43) or magnetic resonance imaging (n = 8). The median delivered dose in equivalent 2-Gy fractions was 72.0 Gy (45 Gy for external-beam radiation therapy and 24 Gy for brachytherapy). Toxicity was reported according to the Common Toxicity Criteria for Adverse Events. Actuarial toxicity estimates were calculated by the Kaplan-Meier method. Results: At diagnosis, the median patient age was 62 years and the median tumor size was 3.8 cm. The median D90 and V100 were 71.4 Gy and 89.5%; the median D2cc for the bladder, rectum, and sigmoid were 64.6 Gy, 61.0 Gy, and 52.7 Gy, respectively. The actuarial rates of all grade 3-4 complications at 2 years were 20% gastrointestinal, 9% vaginal, 6% skin, 3% musculoskeletal, and 2% lymphatic. There were no grade 3-4 genitourinary complications and no grade 5 toxicities. Grade 2-4 rectal toxicity was observed in 10 patients, and grade 3-4 complications in 4; all cases were proctitis with the exception of 1 rectal fistula. D2cc for rectum was higher for patients with grade 2-4 (68 Gy vs 57 Gy for grade 0-1, P=.03) and grade 3-4 (73 Gy vs 58 Gy for grade 0-2, P=.02) rectal toxicity. The estimated dose that resulted in a 10% risk of grade 2-4 rectal toxicity was 61.8 Gy (95% confidence interval, 51.5-72.2 Gy). Discussion: Image-guided HDR interstitial brachytherapy results in acceptable toxicity for women with primary or recurrent gynecologic cancer. D2cc for the rectum is a reliable predictor of late rectal complications. Three-dimensional-based treatment planning should be performed to ensure

  13. Concomitant cervical and transperineal parametrial high-dose-rate brachytherapy boost for locally advanced cervical cancer

    Directory of Open Access Journals (Sweden)

    Caroline Bailleux

    2016-01-01

    Full Text Available Purpose: There is no consensus for parametrial boost technic while both transvaginal and transperineal approaches are discussed. A prototype was developed consisting of a perineal template, allowing transperineal needle insertion. This study analyzed acute toxicity of concomitant cervical and transperineal parametrial high-dose-rate brachytherapy (HDRB boost for locally advanced cervical cancer. Material and methods: From 01.2011 to 12.2014, 33 patients (pts presenting a locally advanced cervical cancer with parametrial invasion were treated. After the first course of external beam radiation therapy with cisplatinum, HDRB was performed combining endocavitary and interstitial technique for cervical and parametrial disease. Post-operative delineation (CTV, bladder, rectum, sigmoid and planification were based on CT-scan/MRI. HDRB was delivered in 3-5 fractions over 2-3 consecutive days. Acute toxicities occurring within 6 months after HDRB were retrospectively reviewed. Results: Median age was 56.4 years (27-79. Clinical stages were: T2b = 23 pts (69.7%, T3a = 1 pt (3%, T3b = 6 pts (18.2%, and T4a = 3 pts (9.1%. Median HDRB prescribed dose was 21 Gy (21-27. Median CTVCT (16 pts and HR-CTV MRI (17 pts were 52.6 cc (28.5-74.3, 31.9 cc (17.1-58, respectively. Median EQD2αβ10 for D90CTV and D90HR-CTV were 82.9 Gy (78.2-96.5, 84.8 Gy (80.6-91.4, respectively. Median EQD2αβ3 (CT/MRI for D2cc bladder, rectum and sigmoid were 75.5 Gy (66.6-90.9, 64.4 Gy (51.9-77.4, and 60.4 Gy (50.9-81.1, respectively. Median follow-up was 14 months (ranged 6-51. Among the 24 pts with MFU = 24 months, 2-year LRFS rate, RRFS, and OS were 86.8%, 88.8%, and 94.1%, respectively. The rates of acute genitourinary and gastrointestinal toxicities were 36% (G1 dysuria = 8 pts, G2 infection = 2 pt, G3 infection = 2 pts, and 27% (G1 diarrhea = 9 pts, respectively. One patient presented vaginal bleeding at the time of applicator withdrawal (G3-blood transfusion; no bleeding was

  14. High-Dose-Rate Prostate Brachytherapy Consistently Results in High Quality Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    White, Evan C.; Kamrava, Mitchell R.; Demarco, John; Park, Sang-June; Wang, Pin-Chieh; Kayode, Oluwatosin; Steinberg, Michael L. [California Endocurietherapy at UCLA, Department of Radiation Oncology, David Geffen School of Medicine of University of California at Los Angeles, Los Angeles, California (United States); Demanes, D. Jeffrey, E-mail: jdemanes@mednet.ucla.edu [California Endocurietherapy at UCLA, Department of Radiation Oncology, David Geffen School of Medicine of University of California at Los Angeles, Los Angeles, California (United States)

    2013-02-01

    Purpose: We performed a dosimetry analysis to determine how well the goals for clinical target volume coverage, dose homogeneity, and normal tissue dose constraints were achieved with high-dose-rate (HDR) prostate brachytherapy. Methods and Materials: Cumulative dose-volume histograms for 208 consecutively treated HDR prostate brachytherapy implants were analyzed. Planning was based on ultrasound-guided catheter insertion and postoperative CT imaging; the contoured clinical target volume (CTV) was the prostate, a small margin, and the proximal seminal vesicles. Dosimetric parameters analyzed for the CTV were D90, V90, V100, V150, and V200. Dose to the urethra, bladder, bladder balloon, and rectum were evaluated by the dose to 0.1 cm{sup 3}, 1 cm{sup 3}, and 2 cm{sup 3} of each organ, expressed as a percentage of the prescribed dose. Analysis was stratified according to prostate size. Results: The mean prostate ultrasound volume was 38.7 {+-} 13.4 cm{sup 3} (range: 11.7-108.6 cm{sup 3}). The mean CTV was 75.1 {+-} 20.6 cm{sup 3} (range: 33.4-156.5 cm{sup 3}). The mean D90 was 109.2% {+-} 2.6% (range: 102.3%-118.4%). Ninety-three percent of observed D90 values were between 105 and 115%. The mean V90, V100, V150, and V200 were 99.9% {+-} 0.05%, 99.5% {+-} 0.8%, 25.4% {+-} 4.2%, and 7.8% {+-} 1.4%. The mean dose to 0.1 cm{sup 3}, 1 cm{sup 3}, and 2 cm{sup 3} for organs at risk were: Urethra: 107.3% {+-} 3.0%, 101.1% {+-} 14.6%, and 47.9% {+-} 34.8%; bladder wall: 79.5% {+-} 5.1%, 69.8% {+-} 4.9%, and 64.3% {+-} 5.0%; bladder balloon: 70.3% {+-} 6.8%, 59.1% {+-} 6.6%, and 52.3% {+-} 6.2%; rectum: 76.3% {+-} 2.5%, 70.2% {+-} 3.3%, and 66.3% {+-} 3.8%. There was no significant difference between D90 and V100 when stratified by prostate size. Conclusions: HDR brachytherapy allows the physician to consistently achieve complete prostate target coverage and maintain normal tissue dose constraints for organs at risk over a wide range of target volumes.

  15. Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations

    Energy Technology Data Exchange (ETDEWEB)

    Granero, Domingo, E-mail: dgranero@eresa.com [Department of Radiation Physics, ERESA, Hospital General Universitario, 46014 Valencia (Spain); Perez-Calatayud, Jose [Radiotherapy Department, La Fe University and Polytechnic Hospital, Valencia 46026 (Spain); Vijande, Javier [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100, Spain and IFIC (UV-CSIC), Paterna 46980 (Spain); Ballester, Facundo [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Rivard, Mark J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States)

    2014-02-15

    Purpose: In skin high-dose-rate (HDR) brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Most treatment planning systems use the TG-43 formalism, which is based on single-source dose superposition within an infinite water medium without accounting for the true geometry in which conditions for scattered radiation are altered by the presence of air. The purpose of this study is to evaluate the dosimetric limitations of the TG-43 formalism in HDR skin brachytherapy and the potential clinical impact. Methods: Dose rate distributions of typical configurations used in skin brachytherapy were obtained: a 5 cm × 5 cm superficial mould; a source inside a catheter located at the skin surface with and without backscatter bolus; and a typical interstitial implant consisting of an HDR source in a catheter located at a depth of 0.5 cm. Commercially available HDR{sup 60}Co and {sup 192}Ir sources and a hypothetical {sup 169}Yb source were considered. The Geant4 Monte Carlo radiation transport code was used to estimate dose rate distributions for the configurations considered. These results were then compared to those obtained with the TG-43 dose calculation formalism. In particular, the influence of adding bolus material over the implant was studied. Results: For a 5 cm × 5 cm{sup 192}Ir superficial mould and 0.5 cm prescription depth, dose differences in comparison to the TG-43 method were about −3%. When the source was positioned at the skin surface, dose differences were smaller than −1% for {sup 60}Co and {sup 192}Ir, yet −3% for {sup 169}Yb. For the interstitial implant, dose differences at the skin surface were −7% for {sup 60}Co, −0.6% for {sup 192}Ir, and −2.5% for {sup 169}Yb. Conclusions: This study indicates the following: (i) for the superficial mould, no bolus is needed; (ii) when the source is in contact with the skin surface, no bolus is needed for either {sup 60}Co and {sup 192}Ir. For

  16. Dosimetric Evaluation of High-Dose-Rate Interstitial Brachytherapy Boost Treatments for Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Froehlich, Georgina [Semmelweis Univ., Budapest (Hungary); Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary); Agoston, Peter; Loevey, Jozsef; Somogyi, Andras; Fodor, Janos; Polgar, Csaba; Major, Tibor [Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary)

    2010-07-15

    Purpose: to quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Material and methods: treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D{sub min}) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D{sub r}) and urethra (D{sub u}), dose to volume of 2 cm{sup 3} of the rectum (D{sub 2ccm}), and 0.1 cm{sup 3} and 1% of the urethra (D{sub 0.1ccm} and D1) were determined. Nonparametric correlation analysis was performed between these parameters. Results: the median number of needles was 16, the mean prostate volume (V{sub p}) was 27.1 cm{sup 3}. The mean V90, V100, V150, and V200 were 90%, 97%, 39% and 13%, respectively. The mean D90 was 109%, and the D{sub min} was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D{sub 2ccm} = 49% for the rectum, D{sub 0.1ccm} = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D{sub r}, D{sub 2ccm}) = 0.69, R(D{sub u}, D{sub 0.1ccm}) = 0.64, R(D{sub u}, D1) = 0.23. Conclusion: US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose

  17. Adaptive planning strategy for high dose rate prostate brachytherapy—a simulation study on needle positioning errors

    NARCIS (Netherlands)

    Borot, Maxence; Denis de Senneville, B; Maenhout, M; Hautvast, G; Binnekamp, D; Lagendijk, J J W; van Vulpen, M; Moerland, M A

    2016-01-01

    The development of magnetic resonance (MR) guided high dose rate (HDR) brachytherapy for prostate cancer has gained increasing interest for delivering a high tumor dose safely in a single fraction. To support needle placement in the limited workspace inside the closed-bore MRI, a single-needle MR-co

  18. High-dose-rate prostate brachytherapy based on registered transrectal ultrasound and in-room cone-beam CT images

    NARCIS (Netherlands)

    Even, Aniek J.G.; Nuver, Tonnis T.; Westendorp, Hendrik; Hoekstra, Carel J.; Slump, C.H.; Minken, Andre W.

    2014-01-01

    Purpose To present a high-dose-rate (HDR) brachytherapy procedure for prostate cancer using transrectal ultrasound (TRUS) to contour the regions of interest and registered in-room cone-beam CT (CBCT) images for needle reconstruction. To characterize the registration uncertainties between the two ima

  19. CT-guided high-dose-rate brachytherapy of unresectable hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, Federico; Schreiber, Nadja; Schnapauff, Dirk; Denecke, Timm; Hamm, Bernd; Gebauer, Bernhard [ChariteUniversitaetsmedizin Berlin, Department of Diagnostic and Interventional Radiology, Berlin (Germany); Wust, Peter [ChariteUniversitaetsmedizin Berlin, Department of Radiation Oncology, Berlin (Germany); Schott, Eckart [Universitaetsmedizin Berlin, Department of Gastroenterology, Berlin (Germany)

    2015-05-01

    The purpose of the present study was to evaluate the clinical outcome of CT-guided high-dose-rate brachytherapy (CT-HDRBT) in patients with unresectable hepatocellular carcinoma (HCC). Over a 6-year period, 98 patients with 212 unresectable HCC underwent CT-HDRBT applying a {sup 192}Ir source at our institution. Magnetic resonance imaging (MRI) follow-up was performed 6 weeks after the intervention and then every 3 months. The primary endpoint was local tumor control (LTC); secondary endpoints included progression-free survival (PFS) and overall survival (OS). Patients were available for MRI evaluation for a mean follow-up of 23.1 months (range 4-64 months; median 20 months). Mean tumor diameter was 5 cm (range 1.8-12 cm). Eighteen of 212 (8.5 %) tumors showed local progression after a mean LTC of 21.1 months. In all, 67 patients (68.4 %) experienced distant tumor progression. The mean PFS was 15.2 months. Forty-six patients died during the follow-up period. Median OS was 29.2 months. Actuarial 1-, 2-, and 3-year OS rates were 80, 62, and 46 %, respectively. CT-HDRBT is an effective therapy to attain local tumor control in patients with unresectable HCC. Prospective randomized studies comparing CT-HDRBT with the standard treatments like Radiofrequency ablation (RFA) and chemoembolization (TACE) are mandatory. (orig.) [German] Zweck der vorliegenden Arbeit war die Analyse der klinischen Effektivitaet der CT-gesteuerten Hochdosis-Brachytherapie (CT-HDRBT) bei Patienten mit inoperablem hepatozellulaeren Karzinom (HCC). Ueber einen Zeitraum von 6 Jahren, wurden an unserer Klinik 98 Patienten mit 212 inoperablen HCC mittels CT-HDRBT mit {sup 192}Ir behandelt. MRT-Verlaufskontrollen erfolgten 6 Wochen nach der Intervention und dann alle 3 Monate. Primaerer Endpunkt der Studie war die lokale Tumorkontrolle (LTC); sekundaere Endpunkte waren das progressionsfreie Ueberleben (PFS) und Gesamtueberleben (OS). Die mittlere Nachbeobachtungszeit betrug 23,1 Monate (Spanne 4

  20. Radioablation of liver malignancies with interstitial high-dose-rate brachytherapy. Complications and risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Mohnike, Konrad; Wolf, Steffen; Damm, Robert; Seidensticker, Max; Seidensticker, Ricarda; Fischbach, Frank; Pech, Maciej; Ricke, Jens [Otto-von-Guericke-Universitaet, Klinik fuer Radiologie und Nuklearmedizin, Universitaetsklinikum Magdeburg A.oe.R., Magdeburg (Germany); Peters, Nils; Hass, Peter; Gademann, Guenther [Otto-von-Guericke-Universitaet, Klinik fuer Strahlentherapie, Universitaetsklinikum Magdeburg A.oe.R., Magdeburg (Germany)

    2016-05-15

    To evaluate complications and identify risk factors for adverse events in patients undergoing high-dose-rate interstitial brachytherapy (iBT). Data from 192 patients treated in 343 CT- or MRI-guided interventions from 2006-2009 at our institution were analyzed. In 41 %, the largest tumor treated was ≥ 5 cm, 6 % of the patients had tumors ≥ 10 cm. Prior to iBT, 60 % of the patients had chemotherapy, 22 % liver resection, 19 % thermoablation or transarterial chemoembolization (TACE). Safety was the primary endpoint; survival data were obtained as the secondary endpoints. During follow-up, MRI or CT imaging was performed and clinical and laboratory parameters were obtained. The rate of major complications was below 5 %. Five major bleedings (1.5 %) occurred. The frequency of severe bleeding was significantly higher in patients with advanced liver cirrhosis. One patient developed signs of a nonclassic radiation-induced liver disease. In 3 patients, symptomatic gastrointestinal (GI) ulcers were detected. A dose exposure to the GI wall above 14 Gy/ml was a reliable threshold to predict ulcer formation. A combination of C-reactive protein ≥ 165 mg/l and/or leukocyte count ≥ 12.7 Gpt/l on the second day after the intervention predicted infection (sensitivity 90.0 %; specificity 92.8 %.) Two patients (0.6 %) died within 30 days. Median overall survival after the first liver treatment was 20.1 months for all patients and the local recurrence-free surviving proportion was 89 % after 12 months. Image-guided iBT yields a low rate of major complications and is effective. (orig.) [German] Evaluierung der Komplikationsrate und Identifizierung von Risikofaktoren fuer Komplikationen und Nebenwirkungen bei Patienten mit Lebermalignomen, die mit der hochdosierten interstitiellen Brachytherapie (iBT) behandelt wurden. Von 2006 bis 2009 wurden 192 Patienten in 343 CT- oder MRT-gefuehrten Interventionen behandelt und deren Daten ausgewertet. Der groesste behandelte Tumor war in

  1. Optimal bladder filling during high-dose-rate intracavitary brachytherapy for cervical cancer: a dosimetric study

    Science.gov (United States)

    Shetty, Saurabha; Majumder, Dipanjan; Adurkar, Pranjal; Swamidas, Jamema; Engineer, Reena; Chopra, Supriya; Shrivastava, Shyamkishore

    2017-01-01

    Purpose The aim of this study is to compare 3D dose volume histogram (DVH) parameters of bladder and other organs at risk with different bladder filling protocol during high-dose-rate intracavitary brachytherapy (HDR-ICBT) in cervical cancer, and to find optimized bladder volume. Material and methods This dosimetric study was completed with 21 patients who underwent HDR-ICBT with computed tomography/magnetic resonance compatible applicator as a routine treatment. Computed tomography planning was done for each patient with bladder emptied (series 1), after 50 ml (series 2), and 100 ml (series 3) bladder filling with a saline infusion through the bladder catheter. Contouring was done on the Eclipse Planning System. 7 Gy to point A was prescribed with the standard loading patterns. Various 3D DVH parameters including 0.1 cc, 1 cc, 2 cc doses and mean doses to the OAR’s were noted. Paired t-test was performed. Results The mean (± SD) bladder volume was 64.5 (± 25) cc, 116.2 (± 28) cc, and 172.9 (± 29) cc, for series 1, 2, and 3, respectively. The 0.1 cm3,1 cm3, 2 cm3 mean bladder doses for series 1, series 2, and series 3 were 9.28 ± 2.27 Gy, 7.38 ± 1.72 Gy, 6.58 ± 1.58 Gy; 9.39 ± 2.28 Gy, 7.85 ± 1.85 Gy, 7.05 ± 1.59 Gy, and 10.09 ± 2.46 Gy, 8.33 ± 1.75 Gy, 7.6 ± 1.55 Gy, respectively. However, there was a trend towards higher bladder doses in series 3. Similarly, for small bowel dose 0.1 cm3, 1 cm3, and 2 cm3 in series 1, 2, and 3 were 5.44 ± 2.2 Gy, 4.41 ± 1.84 Gy, 4 ± 1.69 Gy; 4.57 ± 2.89 Gy, 3.78 ± 2.21 Gy, 3.35 ± 2.02 Gy, and 4.09 ± 2.38 Gy, 3.26 ± 1.8 Gy, 3.05 ± 1.58 Gy. Significant increase in small bowel dose in empty bladder (series 1) compared to full bladder (series 3) (p = 0.03) was noted. However, the rectal and sigmoid doses were not significantly affected with either series. Conclusions Bladder filling protocol with 50 ml and 100 ml was well tolerated and achieved a reasonably reproducible bladder volume during cervical

  2. Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Poulin, Eric; Fekete, Charles-Antoine Collins; Beaulieu, Luc [Département de Physique, de Génie Physique et d’Optique et Centre de recherche sur le cancer de l’Université Laval, Université Laval, Québec, Québec G1V 0A6, Canada and Département de Radio-Oncologie et Axe oncologie du Centre de Recherche du CHU de Québec, CHU de Québec, 11 Côte du Palais, Québec, Québec G1R 2J6 (Canada); Létourneau, Mélanie [Département de Radio-Oncologie, CHU de Québec, 11 Côte du Palais, Québec, Québec G1R 2J6 (Canada); Fenster, Aaron [Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, Ontario N6A 5K8 (United Kingdom); Pouliot, Jean [Department of Radiation Oncology, University of California San Francisco, Helen Diller Family Comprehensive Cancer Center, 1600 Divisadero Street, San Francisco, California 94143-1708 (United States)

    2013-11-15

    Purpose: An innovative, simple, and fast method to optimize the number and position of catheters is presented for prostate and breast high dose rate (HDR) brachytherapy, both for arbitrary templates or template-free implants (such as robotic templates).Methods: Eight clinical cases were chosen randomly from a bank of patients, previously treated in our clinic to test our method. The 2D Centroidal Voronoi Tessellations (CVT) algorithm was adapted to distribute catheters uniformly in space, within the maximum external contour of the planning target volume. The catheters optimization procedure includes the inverse planning simulated annealing algorithm (IPSA). Complete treatment plans can then be generated from the algorithm for different number of catheters. The best plan is chosen from different dosimetry criteria and will automatically provide the number of catheters and their positions. After the CVT algorithm parameters were optimized for speed and dosimetric results, it was validated against prostate clinical cases, using clinically relevant dose parameters. The robustness to implantation error was also evaluated. Finally, the efficiency of the method was tested in breast interstitial HDR brachytherapy cases.Results: The effect of the number and locations of the catheters on prostate cancer patients was studied. Treatment plans with a better or equivalent dose distributions could be obtained with fewer catheters. A better or equal prostate V100 was obtained down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of prostate V100 and D90. Implantation errors up to 3 mm were acceptable since no statistical difference was found when compared to 0 mm error (p > 0.05). No significant difference in dosimetric indices was observed for the different combination of parameters within the CVT algorithm. A linear relation was found between the number of random points and the optimization time of the CVT algorithm. Because the

  3. SU-E-T-165: Characterization of Dose Distributions in High-Dose-Rate Surface Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Buzurovic, I; Hansen, J; Bhagwat, M; O’Farrell, D; Damato, A; Friesen, S; Devlin, P; Cormack, R [Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Boston, MA (United States)

    2015-06-15

    Purpose: To characterize dose distributions in high-dose-rate(HDR) surface brachytherapy using an Ir-125 source for different geometries, field sizes and topology of the clinical targets(CT). To investigate the depth doses at the central axis(CAX), edges of the treatment fields(E), and lateral dose distributions(L) present when using flap applicators in skin cancer treatments. Methods: When malignancies diagnosed on the skin are treated, various geometries of the CT require proper adaptation of the flap or custom-made applicators to the treatment site. Consequently, the dose at the depth on CAX and field edges changes with variation of the curvatures and size of the applicators. To assess the dose distributions, we created a total of 10 treatment plans(TP) for 10×10 and 20×20 field sizes(FS) with a step size of 1cm. The geometry of the applicators was: planar(PA), curved to 30(CA30) and 60(CA60) degrees with respect to the CAX, half-cylinder(HC), and cylindrical shape(CS). One additional TP was created in which the applicators were positioned to form a dome shape(DS) with a diameter of 16cm. This TP was used to emulate treatment of the average sized scalp. All TPs were optimized to deliver a prescription dose at 8mm equidistantly from the planes containing the dwell positions. This optimization is equivalent to the clinical arrangement since the SSD for the flap applicators is 5mm and the prescription depth is 3mm in the majority of clinical cases. Results: The depths (in mm) of the isodose lines were: FS(10×10):PA[90%(9.1CAX,8.0E,7.6L),50%(28.3CAX,20E,17.3L), 25%(51.1CAX,40E,27L)],CA30[90%(10.3CAX,8.2E,7.9L),50%(32.1CAX, 16.2E,15.8L),25%(61.3CAX,36.7E,31.8L)],CA60[90%(12.2CAX,6.1E,6.3L ),50%(47CAX,14E,16.6L),25%(70.8CAX,31.9E,35.4L)],HC[90%(11.1CA X,6.3E,7.3L),50%(38.3CAX,14.6E,16.1L),25%(66.2CAX,33.8E,34.2L)];FS (20×20):PA[90%(11.1CAX,9.0E,7.0L),50%(34.4CAX,21.9E,15.3L),25%(7 0.4CAX,50.9E,34.8L)],CA30[90%(10.9CAX,7.5E,7.1L),50%(38.8CAX,16. 7E,15.4L),25

  4. Intraluminal brachytherapy in the treatment of bile duct carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Leung, J.T. [Adelaide Radiotherapy Centre, Adelaide, SA (Australia); Kuan, R. [Sir Charles Gairdner Hospital, Nedlands, Perth, WA (Australia)

    1997-05-01

    Patients with carcinoma of the biliary tract have a poor prognosis because the disease is often unresectable at diagnosis. Intraluminal brachytherapy has been reported as an effective treatment for localized cholangiocarcinoma of the biliary tract. The purpose of our study was to analyse the survival of patients treated with brachytherapy and make some recommendations regarding its use. Fifteen patients underwent brachytherapy via a trans-hepatic approach at the Royal Prince Alfred Hospital from 1983 to 1993. Eleven patients had low-dose rate brachytherapy and four patients had high-dose rate treatment. There were nine males and six females. The median age was 64 years. Other treatment included bypass procedures in two patients, endoscopic stents in 14 patients and external beam irradiation in one patient. The median survival was 12.5 months and 47% of the patients survived 1 year. The only complication reported was cholangitis which was seen in one patient. There did not seem to be any difference in survival or complications between low- and high-dose rate brachytherapy. It is concluded that the addition of intraluminal brachytherapy after biliary drainage prolongs survival and is a safe and effective treatment, but patients still have a high rate of local failure, and further studies will be needed to address this problem. (authors). 28 refs., 3 figs.

  5. [Prostate cancer boost using high-dose-rate brachytherapy: impact of the learning curve on the dosimetry].

    Science.gov (United States)

    Benhaïm, C; Chand, M-È; Gal, J; Hijazi, H; Gautier, M; Hannoun-Lévi, J-M

    2014-11-01

    To analyse the influence of the learning curve on dosimetric data for high-dose-rate brachytherapy prostate cancer boost. From February 2009 to May 2012, after a first course of external beam radiation therapy (46Gy/23 fractions), 124 patients underwent high-dose-rate brachytherapy boost using Plato™ (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden). The impact of the learning curve on the dosimetric quality of the prostate implant was assessed. The dosimetric data have been analysed: clinical target volume (CTV), D90 (dose to 90 % of CTV), D100, V100 (part on the CTV receiving 100 % of the dose), V150, V200 and DHI (dose non-homogeneity index). The doses delivered to 0.1, 1 and 2 cm(3) of the rectum and urethra were calculated. During the study period (39 months), a significant reduction of V150 (PD100 (P=0.3). This study confirms that the dosimetric quality of high-dose-rate brachytherapy prostate implant is significantly improved during the learning curve period. Copyright © 2014 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  6. The feasibility study and characterization of a two-dimensional diode array in “magic phantom” for high dose rate brachytherapy quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Espinoza, A.; Beeksma, B.; Petasecca, M.; Fuduli, I.; Porumb, C.; Cutajar, D.; Lerch, M. L. F.; Rosenfeld, A. B. [Centre for Medical Radiation Physics, University of Wollongong, New South Wales 2522 (Australia); Corde, S.; Jackson, M. [Department of Radiation Oncology, Prince of Wales Hospital, New South Wales 2031 (Australia)

    2013-11-15

    Purpose: High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly {sup 192}Ir with an air KERMA strength range between 20 000 and 40 000 U, where 1 U = 1 μGy m{sup 2}/h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the functionality of the remote afterloader. This paper describes the feasibility study of a QA system for HDR brachytherapy using a phantom based two-dimensional 11 × 11 epitaxial diode array, named “magic phantom.”Methods: The HDR brachytherapy treatment plan is translated to the phantom with two rows of 10 (20 in total) HDR source flexible catheters, arranged above and below the diode array “magic plate” (MP). Four-dimensional source tracking in each catheter is based upon a developed fast iterative algorithm, utilizing the response of the diodes in close proximity to the {sup 192}Ir source, sampled at 100 ms intervals by a fast data acquisition (DAQ) system. Using a {sup 192}Ir source in a solid water phantom, the angular response of the developed epitaxial diodes utilized in the MP and also the variation of the MP response as a function of the source-to-detector distance (SDD) were investigated. These response data are then used by an iterative algorithm for source dwelling position determination. A measurement of the average transit speed between dwell positions was performed using the diodes and a fast DAQ.Results: The angular response of the epitaxial diode showed a variation of 15% within 360°, with two flat regions above and below the detector face with less than 5% variation. For SDD distances of between 5 and 30 mm

  7. ``In vivo'' Dose Measurements in High-Dose-Rate Brachytherapy Treatments for Cervical Cancer: A Project Proposal

    Science.gov (United States)

    Mejía, C. A. Reynoso; Burgos, A. E. Buenfil; Trejo, C. Ruiz; García, A. Mota; Durán, E. Trejo; Ponce, M. Rodríguez; de Buen, I. Gamboa

    2010-12-01

    The aim of this thesis project is to compare doses calculated from the treatment planning system using computed tomography images, with those measured "in vivo" by using thermoluminescent dosimeters placed at different regions of the rectum and bladder of a patient during high-dose-rate intracavitary brachytherapy treatment of uterine cervical carcinoma. The experimental dosimeters characterisation and calibration have concluded and the protocol to carry out the "in vivo" measurements has been established. In this work, the calibration curves of two types of thermoluminescent dosimeters (rods and chips) are presented, and the proposed protocol to measure the "in vivo" dose is fully described.

  8. Markov chain Monte Carlo analysis for the selection of a cell-killing model under high-dose-rate irradiation.

    Science.gov (United States)

    Matsuya, Yusuke; Kimura, Takaaki; Date, Hiroyuki

    2017-08-08

    High-dose-rate irradiation with 6 MV linac x rays is a wide-spread means to treat cancer tissue in radiotherapy. The treatment planning relies on a mathematical description of surviving fraction (SF), such as the linear-quadratic model (LQM) formula. However, even in the case of high-dose-rate treatment, the repair kinetics of DNA damage during dose-delivery time plays a function in predicting the dose-SF relation. This may call the SF model selection into question when considering the dose-delivery time or dose-rate effects (DREs) in radiotherapy and in vitro cell experiments. In this study, we demonstrate the importance of dose-delivery time at high-dose-rate irradiations used in radiotherapy by means of Bayesian estimation. To evaluate the model selection for SF, three types of models, the LQM and two microdosimetric-kinetic models with and without DREs (MKMDR and MKM) were applied to describe in vitroSF data (our work and references). The parameters in each model were evaluated by a Markov chain Monte Carlo (MCMC) simulation. The MCMC analysis shows that the cell survival curve by the MKMDR fits the experimental data the best in terms of the deviance information criterion (DIC). In the fractionated regimen with 30 fractions to a total dose of 60 Gy, the final cell survival estimated by the MKMDR was higher than that by the LQM. This suggests that additional fractions are required for attaining the total dose equivalent to yield the same effect as the conventional regimen using the LQM in fractionated radiotherapy. Damage repair during dose-delivery time plays a key role in precisely estimating cell survival even at a high dose rate in radiotherapy. Consequently, it was suggested that the cell-killing model without repair factor during a short dose-delivery time may overestimate actual cell killing in fractionated radiotherapy. © 2017 American Association of Physicists in Medicine.

  9. Dedicated high dose rate 192Ir brachytherapy radiation fields for in vitro cell exposures at variable source-target cell distances: killing of mammalian cells depends on temporal dose rate fluctuation

    Science.gov (United States)

    Veigel, Cornelia; Hartmann, Günther H.; Fritz, Peter; Debus, Jürgen; Weber, Klaus-Josef

    2017-02-01

    Afterloading brachytherapy is conducted by the stepwise movement of a radioactive source through surgically implanted applicator tubes where at predefined dwell positions calculated dwell times optimize spatial dose delivery with respect to a planned dose level. The temporal exposure pattern exhibits drastic fluctuations in dose rate at a given coordinate and within a single treatment session because of the discontinuous and repeated source movement into the target volume. This could potentially affect biological response. Therefore, mammalian cells were exposed as monolayers to a high dose rate 192Ir source by utilizing a dedicated irradiation device where the distance between a planar array of radioactive source positions and the plane of the cell monolayer could be varied from 2.5 mm to 40 mm, thus varying dose rate pattern for any chosen total dose. The Gammamed IIi afterloading system equipped with a nominal 370 GBq (10 Ci) 192-Ir source was used to irradiate V79 Chinese hamster lung fibroblasts from both confluent and from exponential growth phase with dose up to 12 Gy (at room temperature, total exposure not exceeding 1 h). For comparison, V79 cells were also exposed to 6 MV x-rays from a clinical linear accelerator (dose rate of 2.5 Gy min-1). As biological endpoint, cell survival was determined by standard colony forming assay. Dose measurements were conducted with a diamond detector (sensitive area 7.3 mm2), calibrated by means of 60Co radiation. Additionally, dose delivery was simulated by Monte Carlo calculations using the EGSnrc code system. The calculated secondary electron fluence spectra at the cell location did not indicate a significant change of radiation quality (i.e. higher linear energy transfer) at the lower distances. Clonogenic cell survival curves obtained after brachytherapy exhibited an altered biological response compared to x-rays which was characterized by a significant reduction of the survival curve shoulder when dose rate

  10. Ion recombination correction factors (P(ion)) for Varian TrueBeam high-dose-rate therapy beams.

    Science.gov (United States)

    Kry, Stephen F; Popple, Richard; Molineu, Andrea; Followill, David S

    2012-11-08

    Ion recombination is approximately corrected for in the Task Group 51 protocol by Pion, which is calculated by a two-voltage measurement. This measurement approach may be a poor estimate of the true recombination, particularly if Pion is large (greater than 1.05). Concern exists that Pion in high-dose-per-pulse beams, such as flattening filter free (FFF) beams, may be unacceptably high, rendering the two-voltage measurement technique inappropriate. Therefore, Pion was measured for flattened beams of 6, 10, 15, and 18 MV and for FFF beams of 6 and 10 MV. The values for the FFF beams were verified with 1/V versus 1/Q curves (Jaffé plots). Pion was also measured for electron beams of 6, 12, 16, 18, and 20 MeV on a traditional accelerator, as well as on the high-dose-rate Varian TrueBeam accelerator. The measurements were made at a range of depths and with PTW, NEL, and Exradin Farmer-type chambers. Consistent with the increased dose per pulse, Pion was higher for FFF beams than for flattening filter beams. However, for all beams, measurement locations, and chambers examined, Pion never exceeded 1.018. Additionally, Pion was always within 0.3% of the recombination calculated from the Jaffé plots. We conclude that ion recombination can be adequately accounted for in high-dose-rate FFF beams using Pion determined with the standard two-voltage technique.

  11. Long term response stability of a well-type ionization chamber used in calibration of high dose rate brachytherapy sources

    Directory of Open Access Journals (Sweden)

    Vandana S

    2010-01-01

    Full Text Available Well-type ionization chamber is often used to measure strength of brachytherapy sources. This study aims to check long term response stability of High Dose Rate (HDR -1000 Plus well-type ionization chamber in terms of reference air kerma rate (RAKR of a reference 137 Cs brachytherapy source and recommend an optimum frequency of recalibration. An HDR-1000 Plus well-type ionization chamber, a reference 137 Cs brachytherapy source (CDCSJ5, and a MAX-4000 electrometer were used in this study. The HDR-1000 Plus well-type chamber was calibrated in terms of reference air kerma rate by the Standards Laboratory of the International Atomic Energy Agency (IAEA, Vienna. The response of the chamber was verified at regular intervals over a period of eight years using the reference 137 Cs source. All required correction factors were applied in the calculation of the RAKR of the 137 Cs source. This study reveals that the response of the HDR-1000 Plus well-type chamber was well within ±0.5% for about three years after calibration/recalibration. However, it shows deviations larger than ±0.5% after three years of calibration/recalibration and the maximum variation in response of the chamber during an eight year period was 1.71%. The optimum frequency of recalibration of a high dose rate well-type chamber should be three years.

  12. Long term response stability of a well-type ionization chamber used in calibration of high dose rate brachytherapy sources.

    Science.gov (United States)

    Vandana, S; Sharma, S D

    2010-04-01

    Well-type ionization chamber is often used to measure strength of brachytherapy sources. This study aims to check long term response stability of High Dose Rate (HDR)-1000 Plus well-type ionization chamber in terms of reference air kerma rate (RAKR) of a reference (137)Cs brachytherapy source and recommend an optimum frequency of recalibration. An HDR-1000 Plus well-type ionization chamber, a reference (137)Cs brachytherapy source (CDCSJ5), and a MAX-4000 electrometer were used in this study. The HDR-1000 Plus well-type chamber was calibrated in terms of reference air kerma rate by the Standards Laboratory of the International Atomic Energy Agency (IAEA), Vienna. The response of the chamber was verified at regular intervals over a period of eight years using the reference (137)Cs source. All required correction factors were applied in the calculation of the RAKR of the (137)Cs source. This study reveals that the response of the HDR-1000 Plus well-type chamber was well within +/-0.5% for about three years after calibration/recalibration. However, it shows deviations larger than +/-0.5% after three years of calibration/recalibration and the maximum variation in response of the chamber during an eight year period was 1.71%. The optimum frequency of recalibration of a high dose rate well-type chamber should be three years.

  13. High dose rate endobronchial brachytherapy: a curative treatment; La curietherapie endobronchique de haut debit de dose: un traitement curatif

    Energy Technology Data Exchange (ETDEWEB)

    Peiffert, D.; Spaeth, D.; Winnefeld, J. [Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France); Menard, O. [Centre Hospitalier Universitaire Nancy-Brabois, 54 - Vandoeuvre-les-Nancy (France)

    2000-06-01

    New endobronchial techniques of treatment allow a good unblocking. Nevertheless, only high dose rate brachytherapy delivers a curative treatment for invasive carcinomas. This study analyses the results of the first 33 consecutive patients treated with curative intent by this technique from 1994 to 1997, and followed-up more than one year. Thirty-seven lesions were treated, with usual schedule delivering 30 Gy at 1 cm depth in six fractions and three to five weeks. All the patients were meticulously selected on the local involvement of the tumour and absolute contraindications to a surgical treatment. All of them have a pulmonary disease history or a general contraindication. With a 14-month follow-up, the local control at two months after the treatment was 95 % (endoscopic and histologic), and 90 % of the patients presented a prolonged local control. Four patients died of the treated cancer, another of a controlateral cancer. Ten patients died of another disease, five of them from a respiratory insufficiency. The overall survival rate at two years was 53 % and the specific survival rate 80 %. The acute tolerance was good, without incident. Asymptomatic bronchial stenoses, described by endoscopic follow-up, were described for seven patients. We conclude that, on the basis of a good selection of the patients, and a respect of the indications, high dose rate endobronchial brachytherapy is an effective curative treatment. It offers a new curative option and must be proposed for the small invasive carcinomas in non-operable patients. (author)

  14. A Performance Evaluation of a Notebook PC under a High Dose-Rate Gamma Ray Irradiation Test

    Directory of Open Access Journals (Sweden)

    Jai Wan Cho

    2014-01-01

    Full Text Available We describe the performance of a notebook PC under a high dose-rate gamma ray irradiation test. A notebook PC, which is small and light weight, is generally used as the control unit of a robot system and loaded onto the robot body. Using TEPCO’s CAMS (containment atmospheric monitoring system data, the gamma ray dose rate before and after a hydrogen explosion in reactor units 1–3 of the Fukushima nuclear power plant was more than 150 Gy/h. To use a notebook PC as the control unit of a robot system entering a reactor building to mitigate the severe accident situation of a nuclear power plant, the performance of the notebook PC under such intense gamma-irradiation fields should be evaluated. Under a similar dose-rate (150 Gy/h gamma ray environment, the performances of different notebook PCs were evaluated. In addition, a simple method for a performance evaluation of a notebook PC under a high dose-rate gamma ray irradiation test is proposed. Three notebook PCs were tested to verify the method proposed in this paper.

  15. SU-C-16A-02: A Beryllium Oxide (BeO) Fibre-Coupled Luminescence Dosimeter for High Dose Rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Santos, A [Royal Adelaide Hospital, Adelaide, South Australia (Australia); Institute for Photonics and Advanced Sensing and School of Chem and Phys, Adelaide, South Australia (Australia); Mohammadi, M [Royal Adelaide Hospital, Adelaide, South Australia (Australia); Afshar, V.S. [Institute for Photonics and Advanced Sensing and School of Chem and Phys, Adelaide, South Australia (Australia)

    2014-06-15

    Purpose: Beryllium oxide (BeO) ceramics have an effective atomic number, zeff ∼7.1, closely matched to water, zeff ∼7.4. The purpose of this study was to evaluate the use of a beryllium oxide (BeO) ceramic fibrecoupled luminescence dosimeter, named RL/OSL BeO FOD, for high dose rate (HDR) brachytherapy dosimetry. In our dosimetry system the radioluminescence (RL) of BeO ceramics is utilized for dose-rate measurements, and the optically stimulated luminescence (OSL) can be read post exposure for accumulated dose measurements. Methods: The RL/OSL BeO FOD consists of a 1 mm diameter × 1 mm long cylinder of BeO ceramic coupled to a 15 m long silica-silica optical fibre. The optical fibre is connected to a custom developed portable RL and OSL reader, located outside of the treatment suite. The x-ray energy response was evaluated using superficial x-rays, an Ir-192 source and high energy linear accelerators. The RL/OSL BeO FOD was then characterised for an Ir-192 source, investigating the dose response and angular dependency. A depth dose curve for the Ir-192 source was also measured. Results: The RL/OSL BeO FOD shows an under-response at low energy x-rays as expected. Though at higher x-ray energies, the OSL response continued to increase, while the RL response remained relatively constant. The dose response for the RL is found to be linear up to doses of 15 Gy, while the OSL response becomes more supralinear to doses above 15 Gy. Little angular dependency is observed and the depth dose curve measured agreed within 4% of that calculated based on TG-43. Conclusion: This works shows that the RL/OSL BeO FOD can be useful in HDR dosimetry. With the RL/OSL BeO FODs current size, it is capable of being inserted into intraluminal catheters and interstitial needles to verify HDR treatments.

  16. On-Line High Dose-Rate Gamma Ray Irradiation Test of the CCD/CMOS Cameras

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Wan; Jeong, Kyung Min [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    In this paper, test results of gamma ray irradiation to CCD/CMOS cameras are described. From the CAMS (containment atmospheric monitoring system) data of Fukushima Dai-ichi nuclear power plant station, we found out that the gamma ray dose-rate when the hydrogen explosion occurred in nuclear reactors 1{approx}3 is about 160 Gy/h. If assumed that the emergency response robot for the management of severe accident of the nuclear power plant has been sent into the reactor area to grasp the inside situation of reactor building and to take precautionary measures against releasing radioactive materials, the CCD/CMOS cameras, which are loaded with the robot, serve as eye of the emergency response robot. In the case of the Japanese Quince robot system, which was sent to carry out investigating the unit 2 reactor building refueling floor situation, 7 CCD/CMOS cameras are used. 2 CCD cameras of Quince robot are used for the forward and backward monitoring of the surroundings during navigation. And 2 CCD (or CMOS) cameras are used for monitoring the status of front-end and back-end motion mechanics such as flippers and crawlers. A CCD camera with wide field of view optics is used for monitoring the status of the communication (VDSL) cable reel. And another 2 CCD cameras are assigned for reading the indication value of the radiation dosimeter and the instrument. In the preceding assumptions, a major problem which arises when dealing with CCD/CMOS cameras in the severe accident situations of the nuclear power plant is the presence of high dose-rate gamma irradiation fields. In the case of the DBA (design basis accident) situations of the nuclear power plant, in order to use a CCD/CMOS camera as an ad-hoc monitoring unit in the vicinity of high radioactivity structures and components of the nuclear reactor area, a robust survivability of this camera in such intense gamma-radiation fields therefore should be verified. The CCD/CMOS cameras of various types were gamma irradiated at a

  17. Real-time inverse high-dose-rate brachytherapy planning with catheter optimization by compressed sensing-inspired optimization strategies.

    Science.gov (United States)

    Guthier, C V; Aschenbrenner, K P; Müller, R; Polster, L; Cormack, R A; Hesser, J W

    2016-08-21

    This paper demonstrates that optimization strategies derived from the field of compressed sensing (CS) improve computational performance in inverse treatment planning (ITP) for high-dose-rate (HDR) brachytherapy. Following an approach applied to low-dose-rate brachytherapy, we developed a reformulation of the ITP problem with the same mathematical structure as standard CS problems. Two greedy methods, derived from hard thresholding and subspace pursuit are presented and their performance is compared to state-of-the-art ITP solvers. Applied to clinical prostate brachytherapy plans speed-up by a factor of 56-350 compared to state-of-the-art methods. Based on a Wilcoxon signed rank-test the novel method statistically significantly decreases the final objective function value (p  plans are either clinically equivalent or show a better performance with respect to dosimetric measures.

  18. Brachytherapy optimization using radiobiological-based planning for high dose rate and permanent implants for prostate cancer treatment

    Science.gov (United States)

    Seeley, Kaelyn; Cunha, J. Adam; Hong, Tae Min

    2017-01-01

    We discuss an improvement in brachytherapy--a prostate cancer treatment method that directly places radioactive seeds inside target cancerous regions--by optimizing the current standard for delivering dose. Currently, the seeds' spatiotemporal placement is determined by optimizing the dose based on a set of physical, user-defined constraints. One particular approach is the ``inverse planning'' algorithms that allow for tightly fit isodose lines around the target volumes in order to reduce dose to the patient's organs at risk. However, these dose distributions are typically computed assuming the same biological response to radiation for different types of tissues. In our work, we consider radiobiological parameters to account for the differences in the individual sensitivities and responses to radiation for tissues surrounding the target. Among the benefits are a more accurate toxicity rate and more coverage to target regions for planning high-dose-rate treatments as well as permanent implants.

  19. Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film

    Directory of Open Access Journals (Sweden)

    Seyed Mohsen Hosseini Daghigh

    2012-03-01

    Full Text Available Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phantom was built in order to be inserted by various sizes of esophageal applicators. EDR2 films were placed at 33 mm from Ir-192 source and irradiated with 1.5 Gy after planning using treatment planning system for all applicators. Results The results of film dosimetry in reference point for 6, 8, 10, and 20 mm applicators were 1.54, 1.53, 1.48, and 1.50 Gy, respectively. The difference between practical and treatment planning system results was 0.023 Gy (

  20. Computed-tomography-guided high-dose-rate brachytherapy (CT-HDRBT) ablation of metastases adjacent to the liver hilum.

    Science.gov (United States)

    Collettini, Federico; Singh, Anju; Schnapauff, Dirk; Powerski, Maciej Janusz; Denecke, Timm; Wust, Peter; Hamm, Bernd; Gebauer, Bernhard

    2013-10-01

    To evaluate technical feasibility and clinical outcome of computed tomography-guided high-dose-rate-brachytherapy (CT-HDRBT) ablation of metastases adjacent to the liver hilum. Between November 2007 and May 2012, 32 consecutive patients with 34 metastases adjacent to the liver hilum (common bile duct or hepatic bifurcation ≤5 mm distance) were treated with CT-HDRBT. Treatment was performed by CT-guided applicator placement and high-dose-rate brachytherapy with an iridium-192 source. MRI follow-up was performed 6 weeks and every 3 months post intervention. The primary endpoint was local tumor control (LTC); secondary endpoints included time to progression (TTP) and overall survival (OS). Patients were available for MRI evaluation for a mean follow-up time of 18.75 months (range: 3-56 months). Mean tumor diameter was 4.3 cm (range: 1.3-10.7 cm). One major complication was observed. Four (11.8%) local recurrences were observed after a local tumor control of 5, 8, 9 and 10 months, respectively. Twenty-two patients (68.75%) experienced a systemic tumor progression during the follow up period. Mean TTP was 12.9 months (range: 2-56 months). Nine patients died during the follow-up period. Median OS was 20.24 months. Minimally invasive CT-HDRBT is a safe and effective option also for unresectable liver metastases adjacent to the liver hilum that would have been untreatable by thermal ablation. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. Computed-tomography-guided high-dose-rate brachytherapy (CT-HDRBT) ablation of metastases adjacent to the liver hilum

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, Federico, E-mail: federico.collettini@charite.de [Department of Radiology, Charité Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin (Germany); Department of Radiation Oncology, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Singh, Anju [Department of Medical Oncology, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Schnapauff, Dirk [Department of Radiology, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Department of Radiation Oncology, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Powerski, Maciej Janusz [Charité – Universitätsmedizin Berlin, Campus Benjamin Franklin, Hindenburgdamm 30, 12203 Berlin (Germany); Department of Radiation Oncology, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); and others

    2013-10-01

    Purpose: To evaluate technical feasibility and clinical outcome of computed tomography-guided high-dose-rate-brachytherapy (CT-HDRBT) ablation of metastases adjacent to the liver hilum. Materials and methods: Between November 2007 and May 2012, 32 consecutive patients with 34 metastases adjacent to the liver hilum (common bile duct or hepatic bifurcation ≤5 mm distance) were treated with CT-HDRBT. Treatment was performed by CT-guided applicator placement and high-dose-rate brachytherapy with an iridium-192 source. MRI follow-up was performed 6 weeks and every 3 months post intervention. The primary endpoint was local tumor control (LTC); secondary endpoints included time to progression (TTP) and overall survival (OS). Results: Patients were available for MRI evaluation for a mean follow-up time of 18.75 months (range: 3–56 months). Mean tumor diameter was 4.3 cm (range: 1.3–10.7 cm). One major complication was observed. Four (11.8%) local recurrences were observed after a local tumor control of 5, 8, 9 and 10 months, respectively. Twenty-two patients (68.75%) experienced a systemic tumor progression during the follow up period. Mean TTP was 12.9 months (range: 2–56 months). Nine patients died during the follow-up period. Median OS was 20.24 months. Conclusion: Minimally invasive CT-HDRBT is a safe and effective option also for unresectable liver metastases adjacent to the liver hilum that would have been untreatable by thermal ablation.

  2. External beam radiotherapy boosted with high dose rate brachytherapy in completely resected uterine sarcomas. Is this a treatment option?

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, Antonio Cassio Assis; Novaes, Paulo Eduardo Ribeiro dos Santos; Maia, Maria Aparecida Conte; Ferrigno, Robson; Fogarolli, Ricardo; Salvajoli, Joao Vitor [Hospital de Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Oncologia de Radiacao]. E-mail: pellizzon@aol.com

    2005-04-15

    Uterine sarcoma (US) is a relative rare tumor, which accounts for only about 3-5% of all uterine cancers. Aggressive cytoreductive surgery at the time of the initial diagnosis with maximum tumor debulking may lead to a prolonged survival or cure. Objective: to identify and review the role of adjuvant external beam radiation therapy (EBRT) associated with high dose rate brachytherapy (HDRB) in the management of patients presenting US with complete resection. Material and methods: this study is a retrospective analysis of 23 patients with US treated from 10/92 to 03/03, with surgery, external beam radiation therapy (EBRT) and high dose rate brachytherapy (HDRB). The inclusion criteria for study participation included: histologically proven and graded US, completely resection of tumor, Karnofsky status 60-100, absence of significant infection, and recovery from recent surgery. Results: The median age of patients was 62 years (range 39-84); ten-year actuarial disease-free and overall survivals were 42.2% and 63.4%, respectively. On univariate analysis, predictive factors for disease-free survival (DFS) were age at initial presentation (p=0.0268), parity (p=0.0441), tumor grade (p= 0.0095), cervical or vaginal invasion (p=0.0014) and node dissection at time of surgery (p= 0.0471). On multivariate analysis, the only predictive factor was cervical or vaginal invasion (p= 0.048), hazard ratio of 4.7. Conclusion: it is quite likely that neither radiotherapy nor chemotherapy alone will appreciably improve survival in US. If radiation therapy provides better locoregional tumor control, hematogenous metastases will assume an even greater proportion of treatment failures. Unfortunately, our small and heterogeneous group analyzed precludes any definitive conclusions about the impact of HDRB associated to EBRT radiation therapy on recurrence or survival. (author)

  3. Study of the stenosis-inhibiting effects of high-dose rate endovascular irradiation in balloon injured rabbit iliac artery

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Masao; Sekine, Hiroshi; Suzuki, Akihiko; Ohyama, Noriaki; Hataba, Yoshiaki [Jikei Univ., Tokyo (Japan). School of Medicine

    2002-12-01

    With scanning electron microscopy, we investigated the effectiveness of inhibition by endovascular irradiation (Ir-192 high dose rate) of intimal hyperplasia after angioplasty. We also examined changes in the irradiated arterial vessel wall after balloon injury and the mechanism of the inhibition of intimal hyperplasia. Japanese white rabbits (male, 3.0-3.5 kg) were used. Under anesthesia, a percutaneous transluminal angioplasty balloon catheter was inserted into the iliac arteries and inflated to 6 atm for 1 minute 3 times at 1-minute intervals. One artery was irradiated (12 Gy) with an iridium-192 high-dose rate endovascular irradiation device (the reference point was set at 2 mm to center; dose rate 18-48 Gy/min). From 2 days to 12 weeks after the procedure, fixation was performed at a perfusion pressure of 120 to 150 cm H{sub 2}O, and the arteries were systematically examined. Endothelial cells after balloon injury with or without irradiation were examined with light microscopy or scanning electron microscopy. Endovascular irradiation inhibited intimal hyperplasia for at least 12 weeks. Irradiated arteries were not constricted, so we assumed that this phenomenon was caused by inhibition of negative remodeling. From 1 to 2 weeks after the procedure, we recognized mild intimal hyperplasia at nonirradiated arteries, but no hyperplasia recognized at irradiated arteries. This hyperplasia was mainly constituted by endothelial cells, and this change happened at least 2 days with scanning electron scopy. At the injury site, platelet aggregation, thrombus, and endothelial cells were observed. After irradiation, endothelial cells and nuclei were injured. Hypertrophic nuclei, the deformity of cell alignment, and stratified endothelial cells were recognized. It means that irradiation may affect the metabolism of the endothelial cells against normal formation with light microscopy. (author)

  4. Absorbed dose-to-water protocol applied to synchrotron-generated x-rays at very high dose rates

    Science.gov (United States)

    Fournier, P.; Crosbie, J. C.; Cornelius, I.; Berkvens, P.; Donzelli, M.; Clavel, A. H.; Rosenfeld, A. B.; Petasecca, M.; Lerch, M. L. F.; Bräuer-Krisch, E.

    2016-07-01

    Microbeam radiation therapy (MRT) is a new radiation treatment modality in the pre-clinical stage of development at the ID17 Biomedical Beamline of the European synchrotron radiation facility (ESRF) in Grenoble, France. MRT exploits the dose volume effect that is made possible through the spatial fractionation of the high dose rate synchrotron-generated x-ray beam into an array of microbeams. As an important step towards the development of a dosimetry protocol for MRT, we have applied the International Atomic Energy Agency’s TRS 398 absorbed dose-to-water protocol to the synchrotron x-ray beam in the case of the broad beam irradiation geometry (i.e. prior to spatial fractionation into microbeams). The very high dose rates observed here mean the ion recombination correction factor, k s , is the most challenging to quantify of all the necessary corrections to apply for ionization chamber based absolute dosimetry. In the course of this study, we have developed a new method, the so called ‘current ramping’ method, to determine k s for the specific irradiation and filtering conditions typically utilized throughout the development of MRT. Using the new approach we deduced an ion recombination correction factor of 1.047 for the maximum ESRF storage ring current (200 mA) under typical beam spectral filtering conditions in MRT. MRT trials are currently underway with veterinary patients at the ESRF that require additional filtering, and we have estimated a correction factor of 1.025 for these filtration conditions for the same ESRF storage ring current. The protocol described herein provides reference dosimetry data for the associated Treatment Planning System utilized in the current veterinary trials and anticipated future human clinical trials.

  5. T3 tongue cancer treated with low- and high-dose rate interstitial brachytherapy using two-plane or volume implant

    Energy Technology Data Exchange (ETDEWEB)

    Kakimoto, Naoya; Murakami, Shumei; Furukawa, Shohei [Osaka Univ., Suita (Japan). Graduate School of Dentistry; Tanaka, Eiichi; Yoshida, Ken; Yamazaki, Hideya; Inoue, Takehiro; Inoue, Toshihiko [Osaka Univ., Suita (Japan). Graduate School of Medicine; Shimizutani, Kimishige [Osaka Dental Coll., Hirakata (Japan)

    2002-11-01

    Fifty-two patients with T3 tongue cancer were treated with low- and high-dose rate interstitial brachytherapy using two-plane or volume implant method. Two-year local control rate was 60% and 3-year overall survival rate was 50%. Low- and high-dose rate interstitial brachytherapy using two-plane or volume implant was effective treatment for T3 tongue cancer with deep infiltration. (author)

  6. Needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer evaluated by repeated MRI.

    Science.gov (United States)

    Buus, Simon; Lizondo, Maria; Hokland, Steffen; Rylander, Susanne; Pedersen, Erik M; Tanderup, Kari; Bentzen, Lise

    2017-09-18

    To quantify needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer and propose a threshold for needle migration. Twenty-four high-risk prostate cancer patients treated with an HDR boost of 2 × 8.5 Gy were included. Patients received an MRI for planning (MRI1), before (MRI2), and after treatment (MRI3). Time from needle insertion to MRI3 was ∼3 hours. Needle migration was evaluated from coregistered images: MRI1-MRI2 and MRI1-MRI3. Dose volume histogram parameters from the treatment plan based on MRI1 were related to parameters based on needle positions in MRI2 or MRI3. Regression was used to model the average needle migration per implant and change in D90 clinical target volume, CTVprostate+3mm. The model fit was used for estimating the dosimetric impact in equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy. Needle migration was on average 2.2 ± 1.8 mm SD from MRI1-MRI2 and 5.0 ± 3.0 mm SD from MRI1-MRI3. D90 CTVprostate+3mm was robust toward average needle migration ≤3 mm, whereas for migration >3 mm D90 decreased by 4.5% per mm. A 3 mm of needle migration resulted in a decrease of 0.9, 1.7, 2.3, 4.8, and 7.6 equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy, respectively. Substantial needle migration in high-dose-rate brachytherapy occurs frequently in 1-3 hours following needle insertion. A 3-mm threshold of needle migration is proposed, but 2 mm may be considered for dose levels ≥15 Gy. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  7. Low and high dose rate heavy ion radiation-induced intestinal and colonic tumorigenesis in APC1638N/+ mice

    Science.gov (United States)

    Suman, Shubhankar; Kumar, Santosh; Moon, Bo-Hyun; Fornace, Albert J.; Datta, Kamal

    2017-05-01

    Ionizing radiation (IR) is a recognized risk factor for colorectal cancer (CRC) and astronauts undertaking long duration space missions are expected to receive IR doses in excess of permissible limits with implications for colorectal carcinogenesis. Exposure to IR in outer space occurs at low doses and dose rates, and energetic heavy ions due to their high linear energy transfer (high-LET) characteristics remain a major concern for CRC risk in astronauts. Previously, we have demonstrated that intestinal tumorigenesis in a mouse model (APC1638N/+) of human colorectal cancer was significantly higher after exposure to high dose rate energetic heavy ions relative to low-LET γ radiation. The purpose of the current study was to compare intestinal tumorigenesis in APC1638N/+ mice after exposure to energetic heavy ions at high (50 cGy/min) and relatively low (0.33 cGy/min) dose rate. Male and female mice (6-8 weeks old) were exposed to either 10 or 50 cGy of 28Si (energy: 300 MeV/n; LET: 70 keV/μm) or 56Fe (energy: 1000 MeV/n; LET: 148 keV/μm) ions at NASA Space Radiation Laboratory in Brookhaven National Laboratory. Mice (n = 20 mice/group) were euthanized and intestinal and colon tumor frequency and size were counted 150 days after radiation exposure. Intestinal tumorigenesis in male mice exposed to 56Fe was similar for high and low dose rate exposures. Although male mice showed a decreasing trend at low dose rate relative to high dose rate exposures, the differences in tumor frequency between the two types of exposures were not statistically significant after 28Si radiation. In female mice, intestinal tumor frequency was similar for both radiation type and dose rates tested. In both male and female mice intestinal tumor size was not different after high and low dose rate radiation exposures. Colon tumor frequency in male and female mice after high and low dose rate energetic heavy ions was also not significantly different. In conclusion, intestinal and colonic tumor

  8. Low and high dose rate heavy ion radiation-induced intestinal and colonic tumorigenesis in APC(1638N/+) mice.

    Science.gov (United States)

    Suman, Shubhankar; Kumar, Santosh; Moon, Bo-Hyun; Fornace, Albert J; Datta, Kamal

    2017-05-01

    Ionizing radiation (IR) is a recognized risk factor for colorectal cancer (CRC) and astronauts undertaking long duration space missions are expected to receive IR doses in excess of permissible limits with implications for colorectal carcinogenesis. Exposure to IR in outer space occurs at low doses and dose rates, and energetic heavy ions due to their high linear energy transfer (high-LET) characteristics remain a major concern for CRC risk in astronauts. Previously, we have demonstrated that intestinal tumorigenesis in a mouse model (APC(1638N/+)) of human colorectal cancer was significantly higher after exposure to high dose rate energetic heavy ions relative to low-LET γ radiation. The purpose of the current study was to compare intestinal tumorigenesis in APC(1638N/+) mice after exposure to energetic heavy ions at high (50cGy/min) and relatively low (0.33cGy/min) dose rate. Male and female mice (6-8 weeks old) were exposed to either 10 or 50cGy of (28)Si (energy: 300MeV/n; LET: 70keV/μm) or (56)Fe (energy: 1000MeV/n; LET: 148keV/μm) ions at NASA Space Radiation Laboratory in Brookhaven National Laboratory. Mice (n=20 mice/group) were euthanized and intestinal and colon tumor frequency and size were counted 150days after radiation exposure. Intestinal tumorigenesis in male mice exposed to (56)Fe was similar for high and low dose rate exposures. Although male mice showed a decreasing trend at low dose rate relative to high dose rate exposures, the differences in tumor frequency between the two types of exposures were not statistically significant after (28)Si radiation. In female mice, intestinal tumor frequency was similar for both radiation type and dose rates tested. In both male and female mice intestinal tumor size was not different after high and low dose rate radiation exposures. Colon tumor frequency in male and female mice after high and low dose rate energetic heavy ions was also not significantly different. In conclusion, intestinal and colonic

  9. Daily CT measurement of needle applicator displacement during multifractionated high-dose-rate interstitial brachytherapy for postoperative recurrent uterine cancer.

    Science.gov (United States)

    Yoshida, Ken; Ueda, Mari; Takenaka, Tadashi; Yamazaki, Hideya; Kotsuma, Tadayuki; Aramoto, Kazumasa; Miyake, Shunsuke; Koretsune, Yukihiro; Ban, Chiaki; Tanaka, Eiichi

    2012-01-01

    We investigated daily needle applicator displacement during multifractionated high-dose-rate interstitial brachytherapy (HDR-ISBT) for postoperative recurrent uterine cancer. Eight patients with postoperative recurrent uterine cancer received HDR-ISBT with or without external beam radiotherapy using our unique ambulatory technique. To analyze displacement, we obtained daily computed tomography (CT) images for 122 flexible needle applicators at 21, 45, 69, and 93 hours after implantation. Displacement was defined as the length between the center of gravity of titanium markers and the needle applicator tips along the daily CT axis. For cases in which displacement was not corrected, we also calculated the dose that covered 90% of the clinical target volume (D90(CTV)) using a dose-volume histogram (DVH). Median caudal needle applicator displacement at 21, 45, 69, and 93 hours was 3, 2, 4, and 5 mm, respectively. More than 15 mm displacement was observed for 2% (2 of 122) and 17% (10 of 60) of needle applicators at 21 and 93 hours, respectively. Cases in which dwell positions were not changed to correct the treatment plan, 2 of 8 patients showed more than 10% reduction in D90(CTV) values compared with the initial treatment plan. Correction of dwell positions of the treatment source improves treatment DVH for multifractionated HDR-ISBT.

  10. Computed tomography-guided interstitial high dose rate brachytherapy for centrally located liver tumours: a single institution study

    Energy Technology Data Exchange (ETDEWEB)

    Tselis, Nikolaos; Chatzikonstantinou, Georgios; Zamboglou, Nikolaos [Klinikum Offenbach, Department of Radiation Oncology, Offenbach am Main (Germany); Kolotas, Christos [Hirslanden Medical Center, Institute for Radiotherapy, Aarau (Switzerland); Milickovic, Natasa; Baltas, Dimos [Klinikum Offenbach, Department of Medical Physics and Engineering, Offenbach am Main (Germany)

    2013-08-15

    To evaluate the clinical outcome of computed tomography (CT)-guided interstitial (IRT) high-dose-rate (HDR) brachytherapy (BRT) in the treatment of unresectable primary and secondary liver malignancies. This report updates and expands our previously described experience with this treatment technique. Forty-one patients with 50 tumours adjacent to the liver hilum and bile duct bifurcation were treated in 59 interventions of CT-guided IRT HDR BRT. The tumours were larger than 4 cm with a median volume of 84 cm{sup 3} (38-1,348 cm{sup 3}). The IRT HDR BRT delivered a median total physical dose of 20.0 Gy (7.0-32.0 Gy) in twice daily fractions of median 7.0 Gy (4.0-10.0 Gy) in 19 patients and in once daily fractions of median 8.0 Gy (7.0-14.0 Gy) in 22 patients. With a median follow-up of 12.4 months, the local control for metastatic hepatic tumours was 89 %, 73 % and 63 % at 6, 12 and 18 months respectively. The local control for primary hepatic tumours was 90 %, 81 % and 50 % at 6, 12 and 18 months respectively. Severe side effects occurred in 5.0 % of interventions with no treatment-related deaths. CT-guided IRT HDR BRT is a promising procedure for the radiation treatment of centrally located liver malignancies. (orig.)

  11. Real-time inverse high-dose-rate brachytherapy planning with catheter optimization by compressed sensing-inspired optimization strategies

    Science.gov (United States)

    Guthier, C. V.; Aschenbrenner, K. P.; Müller, R.; Polster, L.; Cormack, R. A.; Hesser, J. W.

    2016-08-01

    This paper demonstrates that optimization strategies derived from the field of compressed sensing (CS) improve computational performance in inverse treatment planning (ITP) for high-dose-rate (HDR) brachytherapy. Following an approach applied to low-dose-rate brachytherapy, we developed a reformulation of the ITP problem with the same mathematical structure as standard CS problems. Two greedy methods, derived from hard thresholding and subspace pursuit are presented and their performance is compared to state-of-the-art ITP solvers. Applied to clinical prostate brachytherapy plans speed-up by a factor of 56-350 compared to state-of-the-art methods. Based on a Wilcoxon signed rank-test the novel method statistically significantly decreases the final objective function value (p  <  0.01). The optimization times were below one second and thus planing can be considered as real-time capable. The novel CS inspired strategy enables real-time ITP for HDR brachytherapy including catheter optimization. The generated plans are either clinically equivalent or show a better performance with respect to dosimetric measures.

  12. In-Containment Signal Conditioning and Transmission via Power Lines within High Dose Rate Areas of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Steffen; Weigel, Robert; Koelpin, Alexander [Institute for Electronics Engineering, University of Erlangen-Nuremberg, Cauerstr. 9, 91058 Erlangen (Germany); Dennerlein, Juergen; Janke, Iryna; Weber, Johannes [AREVA GmbH, Paul-Gossen-Str. 100, 91052 Erlangen (Germany)

    2015-07-01

    Signal conditioning and transmission for sensor systems and networks within the containment of nuclear power plants (NPPs) still poses a challenge to engineers, particularly in the case of equipment upgrades for existing plants, temporary measurements, decommissioning of plants, but also for new builds. This paper presents an innovative method for efficient and cost-effective instrumentation within high dose rate areas inside the containment. A transmitter-receiver topology is proposed that allows simultaneous, unidirectional point-to-point transmission of multiple sensor signals by superimposing them on existing AC or DC power supply cables using power line communication (PLC) technology. Thereby the need for costly installation of additional cables and containment penetrations is eliminated. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter is designed to operate in harsh environment within the containment during full plant operation. Hardware modularity of the transmitter allows application specific tradeoffs between redundancy and channel bandwidth. At receiver side in non-radiated areas, signals are extracted from the power line, demodulated, and provided either in analog or digital output format. Laboratory qualification tests and field test results within a boiling water reactor (BWR) are validating the proof of concept of the proposed system. (authors)

  13. Comparison of treatment planning on dosimetric differences between 192Ir sources for high-dose rate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Oh Nam [Dept. of Radiology, Mokpo Science University, Mokpo (Korea, Republic of); Shin, Seong Soo; Ahn, Woo Sang; KIm, Dae Yong; Choi, Won Sik [Dept. of Radiation Oncology, Gangenung Asan Hospital, University of Ulsan College of Medicine, Gangenung (Korea, Republic of); Kwon, Kyung Tae [Dept. of Radiologic Technology, Dongam Health University, Suwon (Korea, Republic of); Lim, Cheong Hwan [Dept. of Radiological Science, Hanseo University, Seosan (Korea, Republic of); Lee, Sang Ho [Dept. of Radiological Science, Seonam University, Namwon (Korea, Republic of)

    2016-06-15

    To evaluate whether the difference in geometrical characteristics between high-dose-rate (HDR) 192Ir sources would influence the dose distributions of intracavitary brachytherapy. Two types of microSelectron HDR 192Ir sources (classic and new models) were selected in this study. Two-dimensional (2D) treatment plans for classic and new sources were generated by using PLATO treatment planning system. We compared the point A, point B, and bladder and rectum reference points based on ICRU 38 recommendation. The radial dose function of the new source agrees with that of the classic source except difference of up to 2.6% at the nearest radial distance. The differences of anisotropy functions agree within 2% for r=1, 3, and 5 cm and 20°<θ<165°. The largest discrepancies of anisotropy functions reached up to 27% for θ<20° at r=0.25 cm and were up to 13%, 10%, and 7% at r=1, 3, and 5 cm for θ>170°, respectively. There were no significant differences in doses of point A, point B, and bladder point for the treatment plans between the new and classic sources. For the ICRU rectum point, the percent dose difference was on average 0.65% and up to 1.0%. The dose discrepancies between two treatment plans are mainly affected due to the geometrical difference of the source and the sealed capsule.

  14. High dose rate versus low dose rate brachytherapy for oral cancer--a meta-analysis of clinical trials.

    Directory of Open Access Journals (Sweden)

    Zhenxing Liu

    Full Text Available OBJECTIVE: To compare the efficacy and safety of high dose rate (HDR and low dose rate (LDR brachytherapy in treating early-stage oral cancer. DATA SOURCES: A systematic search of MEDLINE, EMBASE and Cochrane Library databases, restricted to English language up to June 1, 2012, was performed to identify potentially relevant studies. STUDY SELECTION: Only randomized controlled trials (RCT and controlled trials that compared HDR to LDR brachytherapy in treatment of early-stage oral cancer (stages I, II and III were of interest. DATA EXTRACTION AND SYNTHESIS: Two investigators independently extracted data from retrieved studies and controversies were solved by discussion. Meta-analysis was performed using RevMan 5.1. One RCT and five controlled trials (607 patients: 447 for LDR and 160 for HDR met the inclusion criteria. The odds ratio showed no statistically significant difference between LDR group and HDR group in terms of local recurrence (OR = 1.12, CI 95% 0.62-2.01, overall mortality (OR = 1.01, CI 95% 0.61-1.66 and Grade 3/4 complications (OR = 0.86, CI 95% 0.52-1.42. CONCLUSIONS: This meta-analysis indicated that HDR brachytherapy was a comparable alternative to LDR brachytherapy in treatment of oral cancer. HDR brachytherapy might become a routine choice for early-stage oral cancer in the future.

  15. [Pudendal block or combined spinal-epidural anaesthesia in high-dose-rate brachytherapy for prostate carcinoma?].

    Science.gov (United States)

    Schenck, M; Kliner, S J; Achilles, M; Schenck, C; Berkovic, K; Ruebben, H; Stuschke, M

    2010-01-01

    In male patients the pudendal block has been applied only in rare cases as a therapy for neuralgia of the pudendal nerve. Up to now there is no comparison of pudendal block with an anaesthesia form close to the spinal cord. In this pilot study the bilateral perineal infiltration of the pudendal nerve was compared to combined spinal-epidural anaesthesia in high-dose-rate (HDR) brachytherapy. In 30 patients (68.8 +/- 5.4 years) who underwent a core needle biopsy for high-risk prostate carcinoma, an HDR brachytherapy in CSE or NPB was carried out. Both anaesthesia forms were examined concerning the perioperative compatibility, the subjective feeling (German school marks principle 1-6), the pain feeling (VAS, 1-10) and the early postoperative course (mobility, complications). Both anaesthesia procedures were offered to all patients. For 2 patients the NPB was favoured primarily, because they had undergone surgery of the lumbal spine, so that the CSE was not applicable. There was no change of anaesthesia form necessary. The expense of time for NPB was 10.5 +/- 2.5 min, for CSE 30.5 +/- 5.5 min (p subjective feeling in the NPB group was described as 2.06 +/- 0.59 and in the CSE group 2.73 +/- 0.79. This is a significant difference (p subjective feeling there are no essential significant differences. (c) Georg Thieme Verlag Stuttgart - New York.

  16. A hybrid evolutionary algorithm for multi-objective anatomy-based dose optimization in high-dose-rate brachytherapy.

    Science.gov (United States)

    Lahanas, M; Baltas, D; Zamboglou, N

    2003-02-07

    Multiple objectives must be considered in anatomy-based dose optimization for high-dose-rate brachytherapy and a large number of parameters must be optimized to satisfy often competing objectives. For objectives expressed solely in terms of dose variances, deterministic gradient-based algorithms can be applied and a weighted sum approach is able to produce a representative set of non-dominated solutions. As the number of objectives increases, or non-convex objectives are used, local minima can be present and deterministic or stochastic algorithms such as simulated annealing either cannot be used or are not efficient. In this case we employ a modified hybrid version of the multi-objective optimization algorithm NSGA-II. This, in combination with the deterministic optimization algorithm, produces a representative sample of the Pareto set. This algorithm can be used with any kind of objectives, including non-convex, and does not require artificial importance factors. A representation of the trade-off surface can be obtained with more than 1000 non-dominated solutions in 2-5 min. An analysis of the solutions provides information on the possibilities available using these objectives. Simple decision making tools allow the selection of a solution that provides a best fit for the clinical goals. We show an example with a prostate implant and compare results obtained by variance and dose-volume histogram (DVH) based objectives.

  17. A hybrid evolutionary algorithm for multi-objective anatomy-based dose optimization in high-dose-rate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lahanas, M [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach, 63069 Offenbach (Germany); Baltas, D [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach, 63069 Offenbach (Germany); Zamboglou, N [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach, 63069 Offenbach (Germany)

    2003-02-07

    Multiple objectives must be considered in anatomy-based dose optimization for high-dose-rate brachytherapy and a large number of parameters must be optimized to satisfy often competing objectives. For objectives expressed solely in terms of dose variances, deterministic gradient-based algorithms can be applied and a weighted sum approach is able to produce a representative set of non-dominated solutions. As the number of objectives increases, or non-convex objectives are used, local minima can be present and deterministic or stochastic algorithms such as simulated annealing either cannot be used or are not efficient. In this case we employ a modified hybrid version of the multi-objective optimization algorithm NSGA-II. This, in combination with the deterministic optimization algorithm, produces a representative sample of the Pareto set. This algorithm can be used with any kind of objectives, including non-convex, and does not require artificial importance factors. A representation of the trade-off surface can be obtained with more than 1000 non-dominated solutions in 2-5 min. An analysis of the solutions provides information on the possibilities available using these objectives. Simple decision making tools allow the selection of a solution that provides a best fit for the clinical goals. We show an example with a prostate implant and compare results obtained by variance and dose-volume histogram (DVH) based objectives.

  18. Clinical application of the Fricke-glucomannan gel dosimeter for high-dose-rate 192Ir brachytherapy

    Science.gov (United States)

    Noda, S.; Suzuki, Y.; Hoshino, Y.; Furukawa, S.; Katoh, H.; Kurotaki, K.; Nakano, T.

    2008-07-01

    This study investigates the efficacy of a new Fricke dosimeter formulation consisting of a standard Fricke gel dosimeter gelled with glucomannan (FrGDG). FrGDG was irradiated using a 192Ir γ-ray source with a remote afterloading system based on computed tomography images. 60Co irradiation was performed for measuring the absorption of FrGDG and water. The distribution maps of T2 values from the irradiated containers were obtained by MR imaging and converted to the absorbed dose to visualize the dose distribution. We found that FrGDG was produced easily and quickly at room temperature. R2 (1/T2) values were reproducible and linearly correlated with the absorbed doses in the range from 0 to 30 Gy for irradiation with 192Ir (the correlation coefficient was 0.99). The mean deviation between the doses obtained from the MR images of the FrGDG and those calculated by the treatment planning system for doses of 37.5, 40, 50, 62.5 and 75 Gy was 4.9%, 4.8%, 3.5%, 2.3% and 2.4%, respectively. In conclusion, MR imaging of FrGDG can visualize the dose distribution successfully, and thus serves as a useful quality assurance tool for complicated three-dimensional radiotherapy treatments.

  19. Image-Guided High-Dose-Rate (HDR) Boost Localization Using MRI/MR Spectroscopy: A Correlation Study with Biopsy

    Science.gov (United States)

    Mbodji, Khaly; Racine, Louis G; Chevrette, Eric; Lavallee, Marie C; Martin, André-Guy; Despres, Philippe; Beaulieu, Luc

    2016-01-01

    Purpose: The purpose of this study is to compare the blind interpretations of magnetic resonance imaging (MRI) sequences, diffusion-weighted imaging (DWI), apparent diffusion coefficient (ADC), mapping, and magnetic resonance spectroscopy (MRS) of the prostate, in comparison to prostate biopsy to identify a valid dominant intraprostatic lesion (DIL) for dose escalation using high-dose rate brachytherapy. Methods: MRI/MRS were performed on 20 patients with intermediate risk adenocarcinoma of the prostate. T1W, T2W, DWI-ADC, and MRS sequences were performed at 1.5 T with pelvic and endorectal coils. An experienced radiologist rated the presence of cancer in each sextant by using a dichotomic approach, first on MR standard acquisitions (T1W and T2W), then on DWI-ADC mapping, and later on MRS images. Areas under the receiver’s operating characteristic curve were calculated using a sextant as the unit of analysis. The transrectal ultrasonography-guided biopsy results were used as the reference standard. A table summarizing the MRI/MRS findings was made and compared to the corresponding area in the prostate biopsy report. A perfect match was defined to be the presence of cancer in the same sextant of the MRI/MRS exam and the prostate biopsy. Results: The interpretation of the MRI/MRS exams per sextant was compared to the diagnostic biopsy report. MRI readings were compared with the biopsy as a surrogate for the complete pathology specimen of the prostate. A sensitivity (Sn) of 98.6% (95% confidence interval, 92.2% - 99.9%) and specificity (Sp) of 60.8% (46.1% - 74.2%) were found. The positive and negative predictive values (PPV, NPV) were 77.3% (67.1% - 85.5%) and 96.9% (83.8% - 99.9%), respectively. When MRS readings were compared with biopsy, we found a Sn of 96.4% (87.7% - 99.6%) and Sp of 54.8% (38.7% - 70.2%). The PPV and NPV were 74% (62.4% - 83.6%) and 92% (74% - 99%), respectively. DWI-ADC mapping results were also compared with biopsy. We found a Sn and Sp of

  20. Computed tomography-guided high-dose-rate brachytherapy in hepatocellular carcinoma: safety, efficacy, and effect on survival.

    Science.gov (United States)

    Mohnike, Konrad; Wieners, Gero; Schwartz, Franziska; Seidensticker, Max; Pech, Maciej; Ruehl, Ricarda; Wust, Peter; Lopez-Hänninen, Enrique; Gademann, Günther; Peters, Nils; Berg, Thomas; Malfertheiner, Peter; Ricke, Jens

    2010-09-01

    To determine the safety and efficacy of computed tomography (CT)-guided brachytherapy in hepatocellular carcinoma (HCC). A total of 83 patients were recruited, presenting with 140 HCC- lesions. Treatment was performed by CT-guided high-dose-rate (HDR) brachytherapy with an iridium-192 source. The primary endpoint was time to progression; secondary endpoints included local tumor control and overall survival (OS). A matched-pair analysis with patients not receiving brachytherapy was performed. Match criteria included the Cancer of the Liver Italian Program (CLIP) score, alpha-fetoprotein, presence, and extent of multifocal disease. For statistical analysis, Kaplan-Meier and Cox regression were performed. Mean and median cumulative TTP for all patients (n = 75) were 17.7 and 10.4 months. Five local recurrences were observed. The OS after inclusion reached median times of 19.4 months (all patients), 46.3 months (CLIP score, 0), 20.6 months (CLIP score, 1) 12.7 months, (CLIP score, 2), and 8.3 months (CLIP score, >or=3). The 1- and 3-year OS were 94% and 65% (CLIP score, 0), 69% and 12% (CLIP score, 1), and 48% and 19% (CLIP score, 2), respectively. Nine complications requiring intervention were encountered in 124 interventions. Matched-pair analysis revealed a significantly longer OS for patients undergoing CT-guided brachytherapy. Based on our results the study treatment could be safely performed. The study treatment had a beneficial effect on OS in patients with advanced HCC, with respect to (and depending on) the CLIP score and compared with OS in a historical control group. A high rate of local control was also observed, regardless of applied dose in a range of 15 to 25 Gy. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  1. High-Dose-Rate Interstitial Brachytherapy as Monotherapy for Clinically Localized Prostate Cancer: Treatment Evolution and Mature Results

    Energy Technology Data Exchange (ETDEWEB)

    Zamboglou, Nikolaos [Department of Radiation Oncology, Klinikum Offenbach, Offenbach (Germany); Tselis, Nikolaos, E-mail: ntselis@hotmail.com [Department of Radiation Oncology, Klinikum Offenbach, Offenbach (Germany); Baltas, Dimos [Department of Medical Physics and Engineering, Klinikum Offenbach, Offenbach (Germany); Buhleier, Thomas [Department of Radiation Oncology, Klinikum Offenbach, Offenbach (Germany); Martin, Thomas [Department of Radiation Oncology, Klinikum Bremen-Mitte, Bremen (Germany); Milickovic, Natasa; Papaioannou, Sokratis [Department of Medical Physics and Engineering, Klinikum Offenbach, Offenbach (Germany); Ackermann, Hanns [Institute of Biostatistics, J.W. Goethe University of Frankfurt, Frankfurt (Germany); Tunn, Ulf W. [Department of Urology, Klinikum Offenbach, Offenbach (Germany)

    2013-03-01

    Purpose: To report the clinical outcome of high-dose-rate (HDR) interstitial (IRT) brachytherapy (BRT) as sole treatment (monotherapy) for clinically localized prostate cancer. Methods and Materials: Between January 2002 and December 2009, 718 consecutive patients with clinically localized prostate cancer were treated with transrectal ultrasound (TRUS)-guided HDR monotherapy. Three treatment protocols were applied; 141 patients received 38.0 Gy using one implant in 4 fractions of 9.5 Gy with computed tomography-based treatment planning; 351 patients received 38.0 Gy in 4 fractions of 9.5 Gy, using 2 implants (2 weeks apart) and intraoperative TRUS real-time treatment planning; and 226 patients received 34.5 Gy, using 3 single-fraction implants of 11.5 Gy (3 weeks apart) and intraoperative TRUS real-time treatment planning. Biochemical failure was defined according to the Phoenix consensus, and toxicity was evaluated using Common Toxicity Criteria for Adverse Events version 3. Results: The median follow-up time was 52.8 months. The 36-, 60-, and 96-month biochemical control and metastasis-free survival rates for the entire cohort were 97%, 94%, and 90% and 99%, 98%, and 97%, respectively. Toxicity was scored per event, with 5.4% acute grade 3 genitourinary and 0.2% acute grade 3 gastrointestinal toxicity. Late grade 3 genitourinary and gastrointestinal toxicities were 3.5% and 1.6%, respectively. Two patients developed grade 4 incontinence. No other instance of grade 4 or greater acute or late toxicity was reported. Conclusion: Our results confirm IRT-HDR-BRT is safe and effective as monotherapy for clinically localized prostate cancer.

  2. Validation study of ultrasound-based high-dose-rate prostate brachytherapy planning compared with CT-based planning.

    Science.gov (United States)

    Batchelar, Deidre; Gaztañaga, Miren; Schmid, Matt; Araujo, Cynthia; Bachand, François; Crook, Juanita

    2014-01-01

    The use of transrectal ultrasound (TRUS) to both guide and plan high-dose-rate (HDR) brachytherapy (BT) for prostate is increasing. Studies using prostate phantoms have demonstrated the accuracy of ultrasound (US) needle tip reconstruction compared with CT imaging standard. We have assessed the in vivo accuracy of needle tip localization by TRUS using cone-beam CT (CBCT) as our reference standard. Needle positions from 37 implants have been analyzed. A median of 16 needles (range, 16-18) per implant were inserted, advanced to the prostate base, and their tips identified using live TRUS images and real-time planning BT software. Needle protrusion length from the template was recorded to allow for reverification before capturing images for planning. The needles remained locked in the template, which was fixed to the stepper, while a set of three-dimensional TRUS images was acquired for needle path reconstruction and HDR-BT treatment planning. Following treatment, CBCT images were acquired for subsequent needle reconstruction using a BT Treatment Planning System. The coordinates of each needle tip were recorded from the Treatment Planning System for CT and US and compared. A total of 574 needle tip positions have been compared between TRUS and CBCT. Of these, 59% agreed within 1 mm, 27% within 1-2 mm, and 11% agreed within 2-3 mm. The discrepancy between tip positions in the two modalities was greater than 3 mm for only 20 needles (3%). The US needle tip identification in vivo is at least as accurate as CT identification, while providing all the advantages of a one-step procedure. Copyright © 2014 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  3. Adaptive planning strategy for high dose rate prostate brachytherapy—a simulation study on needle positioning errors.

    Science.gov (United States)

    Borot de Battisti, M; Denis de Senneville, B; Maenhout, M; Hautvast, G; Binnekamp, D; Lagendijk, J J W; van Vulpen, M; Moerland, M A

    2016-03-01

    The development of magnetic resonance (MR) guided high dose rate (HDR) brachytherapy for prostate cancer has gained increasing interest for delivering a high tumor dose safely in a single fraction. To support needle placement in the limited workspace inside the closed-bore MRI, a single-needle MR-compatible robot is currently under development at the University Medical Center Utrecht (UMCU). This robotic device taps the needle in a divergent way from a single rotation point into the prostate. With this setup, it is warranted to deliver the irradiation dose by successive insertions of the needle. Although robot-assisted needle placement is expected to be more accurate than manual template-guided insertion, needle positioning errors may occur and are likely to modify the pre-planned dose distribution.In this paper, we propose a dose plan adaptation strategy for HDR prostate brachytherapy with feedback on the needle position: a dose plan is made at the beginning of the interventional procedure and updated after each needle insertion in order to compensate for possible needle positioning errors. The introduced procedure can be used with the single needle MR-compatible robot developed at the UMCU. The proposed feedback strategy was tested by simulating complete HDR procedures with and without feedback on eight patients with different numbers of needle insertions (varying from 4 to 12). In of the cases tested, the number of clinically acceptable plans obtained at the end of the procedure was larger with feedback compared to the situation without feedback. Furthermore, the computation time of the feedback between each insertion was below 100 s which makes it eligible for intra-operative use.

  4. Development of 3D ultrasound needle guidance for high-dose-rate interstitial brachytherapy of gynaecological cancers

    Science.gov (United States)

    Rodgers, J.; Tessier, D.; D'Souza, D.; Leung, E.; Hajdok, G.; Fenster, A.

    2016-04-01

    High-dose-rate (HDR) interstitial brachytherapy is often included in standard-of-care for gynaecological cancers. Needles are currently inserted through a perineal template without any standard real-time imaging modality to assist needle guidance, causing physicians to rely on pre-operative imaging, clinical examination, and experience. While two-dimensional (2D) ultrasound (US) is sometimes used for real-time guidance, visualization of needle placement and depth is difficult and subject to variability and inaccuracy in 2D images. The close proximity to critical organs, in particular the rectum and bladder, can lead to serious complications. We have developed a three-dimensional (3D) transrectal US system and are investigating its use for intra-operative visualization of needle positions used in HDR gynaecological brachytherapy. As a proof-of-concept, four patients were imaged with post-insertion 3D US and x-ray CT. Using software developed in our laboratory, manual rigid registration of the two modalities was performed based on the perineal template's vaginal cylinder. The needle tip and a second point along the needle path were identified for each needle visible in US. The difference between modalities in the needle trajectory and needle tip position was calculated for each identified needle. For the 60 needles placed, the mean trajectory difference was 3.23 +/- 1.65° across the 53 visible needle paths and the mean difference in needle tip position was 3.89 +/- 1.92 mm across the 48 visible needles tips. Based on the preliminary results, 3D transrectal US shows potential for the development of a 3D US-based needle guidance system for interstitial gynaecological brachytherapy.

  5. Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'

    Energy Technology Data Exchange (ETDEWEB)

    Salter, Bill J; Sarkar, Vikren; Wang, Brian; Szegedi, Martin; Rassiah-Szegedi, Prema [Department of Radiation Oncology, University of Utah, Salt Lake City, UT (United States); Shukla, Himanshu, E-mail: bill.salter@hci.utah.edu [Oncology Care Systems Group, Siemens Medical Solutions (USA), 4040 Nelson Avenue, Concord, CA (United States)

    2011-04-07

    Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units per minute (MU min{sup -1}) high dose rate bursts of dose are facilitated by a flattening-filter-free treatment beam on a Siemens Artiste (Oncology Care Systems, Siemens Medical Solutions, Concord, CA, USA) digital linear accelerator in a non-clinical configuration. Burst mode delivery differs from continuous mode delivery, used by Elekta's VMAT (Elekta Ltd, Crawley, UK) and Varian's RapidArc (Varian Medical Systems, Palo Alto, CA, USA) implementations, in that dose is not delivered while MLC leaves are moving. Instead, dose is delivered in bursts over very short arc angles and only after an MLC segment shape has been completely formed and verified by the controller. The new system was confirmed to be capable of delivering a wide array of clinically relevant treatment plans, without machine fault or other delivery anomalies. Dosimetric accuracy of the modulated arc platform, as well as the Prowess (Prowess Inc., Concord, CA, USA) prototype treatment planning version utilized here, was quantified and confirmed, and delivery times were measured as significantly brief, even with large hypofractionated doses. The burst mode modulated arc approach evaluated here appears to represent a capable, accurate and efficient delivery approach.

  6. Experimental determination of the energy response of alanine pellets in the high dose rate 192Ir spectrum

    Science.gov (United States)

    Schaeken, B.; Cuypers, R.; Goossens, J.; Van den Weyngaert, D.; Verellen, D.

    2011-10-01

    An experimental determination of the energy correction factor for alanine/paraffin pellets in the 192Ir spectrum at varying distances from the source is presented. Alanine dosimeters were irradiated in water under full scatter conditions with a high dose rate (HDR) 192Ir source (Flexisource), using a dedicated holder. Up to six line sources (catheters) fit in a regular pattern at fixed radial distances from the holder axis, the alanine detector being placed at the centre of the holder. The HDR source was stepping every 0.5 cm within a trocar needle within ± 3.0 cm around the medial plane through the detector in order to achieve dose homogeneity within the detector volume. The energy correction factor of alanine/paraffin pellets in 192Ir relative to 60Co was experimentally determined as the inverse ratio of the dose to water measured in water around the 192Ir source to the dose to water calculated in water using the TG-43 formalism. The pellets were read out with a Bruker EMXmicro spectrometer (X-band). The amplitude of the central line in the alanine absorption spectrum from pellets irradiated within the 192Ir spectrum was directly compared with the amplitude from 60Co-irradiated pellets. The energy correction factors of Harwell pellets irradiated in the 192Ir spectrum are 1.029 ± 0.02, 1.027 ± 0.02 and 1.045 ± 0.02 at a mean weighted source-detector distance of 2.0, 2.9 and 5.3 cm, respectively. The experimentally obtained values for the energy response are 1.3% lower compared to the theoretical values for radial distances smaller than 3 cm.

  7. Treatment results of radical radiotherapy of carcinoma uterine cervix using external beam radiotherapy and high dose rate intracavitary radiotherapy

    Directory of Open Access Journals (Sweden)

    Azad S

    2010-01-01

    Full Text Available Aim: To report the outcome of carcinoma cervix patients treated radically by external beam radiotherapy and high dose rate intracavitary radiotherapy. Material and Methods: From January 2005 to December 2006, a total of 709 newly diagnosed cases of carcinoma cervix were reported in our department. All cases were staged according to the International Federation of Gynecologist and Oncologist staging system. Out of 709 cases, 342 completed radical radiotherapy and were retrospectively analyzed for the presence of local residual disease, local recurrence, distant metastases, radiation reaction, and disease free survival. Results: There were 11(3.22%, 82(23.98%, 232(67.83%, and 17(4.97% patients in stages I, II, III, and IV, respectively. The median follow up time for all patients was 36 months (range 3 -54 months. The overall treatment time (OTT ranged from 52 to 69 days (median 58 days. The 3 year disease free survival rate was 81.8%, 70.7%, 40.08%, and 11.76% for stages I, II, III, and IV, respectively. There were 91 (26.6% cases with local residual diseases, 27(7.9% developed distant metastasis, and 18(5.26% pts had local recurrence. Discussion: The results of this study suggest that radical radiotherapy with HDR brachytherapy was appropriate for the treatment of early staged cancer of uterine cervix. For locally advanced cancer of cervix addition of concurrent chemotherapy, higher radiation doses, reduction of overall treatment time to less than 8 weeks, and use of latest radiotherapy techniques such as IMRT is recommended to improve the results.

  8. Image guided radiation therapy boost in combination with high-dose-rate intracavitary brachytherapy for the treatment of cervical cancer.

    Science.gov (United States)

    Wang, Xianliang; Li, Jie; Wang, Pei; Yuan, Ke; Yin, Gang; Wan, Bin

    2016-04-01

    The purpose of this study was to demonstrate the dosimetric and clinical feasibility of image guided radiation therapy (IGRT) combined with high-dose-rate (HDR) intracavitary brachytherapy (ICBT) to improve dose distribution in cervical cancer treatment. For 42 cervical cancer patients, magnetic resonance imaging (MRI) scans were acquired after completion of whole pelvic irradiation 45-46 Gy and 5 fractions of B + I (ICBT + IGRT) treatment were subsequently received. The high risk clinical target volume (HRCTV), intermediate risk clinical target volume (IRCTV), bladder, rectum, and sigmoid were contoured on the computed tomography (CT) scans. The total planning aim doses for HRCTV was D90% > 85 Gy, whilst constraints for rectum and sigmoid were D2cc D100%, IRCTV D100%, and IRCTV D90% were significantly increased by a mean of 10.52 Gy, 5.61 Gy, and 2.70 Gy, respectively (p < 0.01). The D2cc for bladder, rectum, and sigmoid were lower by a mean of 21.36, 6.78, and 10.65 Gy, respectively (p < 0.01). The mean rectum V60 Gy value over 42 patients was almost the same for both techniques but for bladder and sigmoid B + I had higher V60 Gy mean values as compared with the O-ICBT. B + I can improve dose distribution in cervical cancer treatment; it could be useful for tumors extended beyond the reach of intracavitary/interstitial brachytherapy (IC/ISBT) or for centers that are inexperienced or ill-equipped with IC/ISBT techniques. Additional confirmatory prospective studies with larger numbers of patients and longer follow-up are required to validate the durability.

  9. 360-degree 3D transvaginal ultrasound system for high-dose-rate interstitial gynaecological brachytherapy needle guidance

    Science.gov (United States)

    Rodgers, Jessica R.; Surry, Kathleen; D'Souza, David; Leung, Eric; Fenster, Aaron

    2017-03-01

    Treatment for gynaecological cancers often includes brachytherapy; in particular, in high-dose-rate (HDR) interstitial brachytherapy, hollow needles are inserted into the tumour and surrounding area through a template in order to deliver the radiation dose. Currently, there is no standard modality for visualizing needles intra-operatively, despite the need for precise needle placement in order to deliver the optimal dose and avoid nearby organs, including the bladder and rectum. While three-dimensional (3D) transrectal ultrasound (TRUS) imaging has been proposed for 3D intra-operative needle guidance, anterior needles tend to be obscured by shadowing created by the template's vaginal cylinder. We have developed a 360-degree 3D transvaginal ultrasound (TVUS) system that uses a conventional two-dimensional side-fire TRUS probe rotated inside a hollow vaginal cylinder made from a sonolucent plastic (TPX). The system was validated using grid and sphere phantoms in order to test the geometric accuracy of the distance and volumetric measurements in the reconstructed image. To test the potential for visualizing needles, an agar phantom mimicking the geometry of the female pelvis was used. Needles were inserted into the phantom and then imaged using the 3D TVUS system. The needle trajectories and tip positions in the 3D TVUS scan were compared to their expected values and the needle tracks visualized in magnetic resonance images. Based on this initial study, 360-degree 3D TVUS imaging through a sonolucent vaginal cylinder is a feasible technique for intra-operatively visualizing needles during HDR interstitial gynaecological brachytherapy.

  10. High-dose rate brachytherapy as monotherapy in prostate cancer: A systematic review of its safety and efficacy.

    Science.gov (United States)

    Sánchez-Gómez, L M; Polo-deSantos, M; Rodríguez-Melcón, J I; Angulo, J C; Luengo-Matos, S

    2017-03-01

    High-dose rate brachytherapy (HDR-BT) is an increasingly popular treatment for patients with localised prostate cancer (PC). To assess the safety and efficacy of HDR-BT as monotherapy in PC. A systematic literature review was conducted through searches on MEDLINE (PubMed), Cochrane Library, CDR, ClinicalTrials and EuroScan. We assessed safety and efficacy indicators. We selected 2 reviews and 12 uncontrolled studies, included in these 2 reviews. In terms of efficacy, local control in 6 studies was 97-100%. The biochemical progression-free survival varied as follows: 85-100% for low risk and 79-92% for high risk. Survival free of metastases was >95% at 8 years, except in one study where the survival rate was 87% at 5 years. The overall survival was ≥95% in 8 studies. In terms of safety, most of the studies recorded acute and long-term genitourinary and gastrointestinal complications, especially grade ≥2. Only 3 studies found grade 4 complications. All studies, except for one without complications, observed genitourinary complications that were more frequent and severe than the gastrointestinal complications. Two studies assessed the quality of life and showed an initial reduction in various domains and subsequent partial or total recovery, except in the sexual domain. HDR-BT is effective as monotherapy, especially in cases of low to intermediate risk. There is insufficient information on high-risk patients. The short to medium-term toxicity was acceptable. Further research needs to be funded to provide more information on the long-term safety and efficacy of this treatment. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Rectal complication after remote afterloading intracavitary therapy for carcinoma of the uterine cervix

    Energy Technology Data Exchange (ETDEWEB)

    Teshima, T.; Chatani, M.; Hata, K.; Inoue, Ta.; Inoue, To.; Suzuki, T.

    1985-06-01

    From August 1978 through December 1980, 119 patients of previously untreated carcinoma of the uterine cervix were treated using RALS, remote afterloading high dose rate intracavitary therapy at our department. The data from 92 out of 119 patients were available for analysis of rectal complication. The incidence of major rectal complications was only 2% (2/92). Uni- and multivariate analyses were used based on the external criterion variable of rectal complication which included even minor injuries. By using these methods, it was clearly indicated that these factors such as TDF of rectum, Z-coordinate of weighted geometric center (WGC-Z), the dose of whole pelvic irradiation, history of chemotherapy and Treponema pallidum hemoagglutination test (TPHA) were important for occurrence of rectal complication. According to discriminant score, 71 out of 92 cases (77%) could be correctly discriminated.

  12. 20-Year Experience With Intraoperative High-Dose-Rate Brachytherapy for Pediatric Sarcoma: Outcomes, Toxicity, and Practice Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Folkert, Michael R.; Tong, William Y. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); LaQuaglia, Michael P. [Department of Pediatric Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Wexler, Leonard H.; Chou, Alexander J.; Magnan, Heather [Department of Pediatrics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Zelefsky, Michael J. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Wolden, Suzanne L., E-mail: woldens@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)

    2014-10-01

    Purpose: To assess outcomes and toxicity of high-dose-rate intraoperative radiation therapy (HDR-IORT) in the management of pediatric sarcoma. Methods and Materials: Seventy-five pediatric patients underwent HDR-IORT for sarcoma from May 1993 to November 2013. The median age was 9 years old (36 patients were ≤6 years old). HDR-IORT was part of initial therapy in 37 patients (49%) and for recurrent disease in 38 patients (51%). Forty-one patients (55%) received HDR-IORT and postoperative external beam RT (PORT), and 22 patients (29%) were previously treated with external beam radiation therapy to the IORT site. Local control (LC), overall survival (OS) and event-free survival (EFS) were estimated using Kaplan-Meier methods. Results: At a median follow-up of 7.8 years for surviving patients, 5-year projected rates of LC, EFS, and OS were 63% (95% confidence interval [CI] 50%-76%), 33% (95% CI 21%-45%), and 43% (95% CI 30%-55%), with a median survival of 3.1 years. The 5-year LC, EFS, and OS rates for patients with recurrent disease were 46% (95% CI, 28%-64%), 30% (95% CI, 13%-46%), and 36% (95% CI, 18%-54%). Acute toxicity ≥grade 3 occurred in 2 (2.5%) treatments; late toxicity ≥grade 3 occurred in 4 (5.3%) patients 0.3-9.9 years after HDR-IORT. The incidence of toxicity ≥grade 3 was not associated with HDR-IORT applicator size, HDR-IORT dose, prior RT or PORT, or prior or postoperative chemotherapy, but all toxicity ≥grade 3 occurred in patients ≤6 years treated with HDR-IORT doses ≥12 Gy. Conclusions: HDR-IORT is a well-tolerated component of multimodality therapy for pediatric sarcoma, allowing additional local treatment while reducing external beam exposure. Taking clinical considerations into account, doses between 8-12 Gy are appropriate for HDR-IORT in patients ≤6 years of age.

  13. High-Dose-Rate Brachytherapy as a Monotherapy for Favorable-Risk Prostate Cancer: A Phase II Trial

    Energy Technology Data Exchange (ETDEWEB)

    Barkati, Maroie [Division of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Williams, Scott G., E-mail: scott.williams@petermac.org [Division of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Department of Pathology, University of Melbourne, Melbourne (Australia); Foroudi, Farshad; Tai, Keen Hun; Chander, Sarat [Division of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Department of Pathology, University of Melbourne, Melbourne (Australia); Dyk, Sylvia van [Division of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); See, Andrew [Ballarat Austin Radiation Oncology Centre, Ballarat (Australia); Duchesne, Gillian M. [Division of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Department of Pathology, University of Melbourne, Melbourne (Australia)

    2012-04-01

    Purpose: There are multiple treatment options for favorable-risk prostate cancer. High-dose-rate (HDR) brachytherapy as a monotherapy is appealing, but its use is still investigational. A Phase II trial was undertaken to explore the value of such treatment in low-to-intermediate risk prostate cancer. Methods and Materials: This was a single-institution, prospective study. Eligible patients had low-risk prostate cancer features but also Gleason scores of 7 (51% of patients) and stage T2b to T2c cancer. Treatment with HDR brachytherapy with a single implant was administered over 2 days. One of four fractionation schedules was used in a dose escalation study design: 3 fractions of 10, 10.5, 11, or 11.5 Gy. Patients were assessed with the Common Terminology Criteria for Adverse Events version 2.0 for urinary toxicity, the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer scoring schema for rectal toxicity, and the Expanded Prostate Cancer Index Composite (EPIC) questionnaire to measure patient-reported health-related quality of life. Biochemical failure was defined as a prostate-specific antigen (PSA) nadir plus 2 ng/ml. Results: Between 2003 and 2008, 79 patients were enrolled. With a median follow-up of 39.5 months, biochemical relapse occurred in 7 patients. Three- and 5-year actuarial biochemical control rates were 88.4% (95% confidence interval [CI], 78.0-96.2%) and 85.1% (95% CI, 72.5-94.5%), respectively. Acute grade 3 urinary toxicity was seen in only 1 patient. There was no instance of acute grade 3 rectal toxicity. Rates of late grade 3 rectal toxicity, dysuria, hematuria, urinary retention, and urinary incontinence were 0%, 10.3%, 1.3%, 9.0%, and 0%, respectively. No grade 4 or greater toxicity was recorded. Among the four (urinary, bowel, sexual, and hormonal) domains assessed with the EPIC questionnaire, only the sexual domain did not recover with time. Conclusions: HDR brachytherapy as a monotherapy for favorable

  14. Comparison of single and multiple dwell position methods in MammoSite high dose rate (HDR) brachytherapy planning.

    Science.gov (United States)

    Kim, Yongbok; Trombetta, Mark G; Miften, Moyed

    2010-05-28

    The purpose of this study is to dosimetrically compare two plans generated using single dwell position method (SDPM) and multiple dwell position methods (MDPM) in MammoSite high dose rate (HDR) brachytherapy planning for 19 breast cancer patients. In computed tomography (CT) image-based HDR planning, a surface optimization technique was used in both methods. Following dosimetric parameters were compared for fraction 1 plans: %PTV_EVAL (planning target volume for plan evaluation) coverage, dose homogeneity index (DHI), dose con-formal index (COIN), maximum dose to skin and ipsilateral lung, and breast tissue volume receiving 150% (V150[cc]) and 200% (V200[cc]) of the prescribed dose. In addition, a plan was retrospectively generated for each fraction 2-10 to simulate the clinical situation where the fraction 1 plan was used for fractions 2-10 without modification. In order to create nine derived plans for each method and for each of the 19 patients, the catheter location and contours of target and critical structures were defined on the CT images acquired prior to each fraction 2-10, while using the same dwell-time distribution as used for fraction 1 (original plan). Interfraction dose variations were evaluated for 19 patients by comparing the derived nine plans (each for fractions 2-10) with the original plan (fraction 1) using the same dosimetric parameters used for fraction 1 plan comparison. For the fraction 1 plan comparison, the MDPM resulted in slightly increased %PTV_EVAL coverage, COIN, V150[cc] and V200[cc] values by an average of 1.2%, 0.025, 0.5 cc and 0.7cc, respectively, while slightly decreased DHI, maximum skin and ipsilateral lung dose by an average of 0.003, 3.2 cGy and 5.8 cGy, respectively. For the inter-fraction dose variation comparison, the SDPM resulted in slightly smaller variations in %PTV_EVAL coverage, DHI, maximum skin dose and V150[cc] values by an average of 0.4%, 0.0005, 0.5 cGy and 0.2 cc, respectively, while slightly higher average

  15. Development of a phantom to validate high-dose-rate brachytherapy treatment planning systems with heterogeneous algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo S., E-mail: emoura@wisc.edu [Department of Medical Physics, University of Wisconsin–Madison, Madison, Wisconsin 53705 and Instituto de Pesquisas Energéticas e Nucleares—IPEN-CNEN/SP, São Paulo 05508-000 (Brazil); Micka, John A.; Hammer, Cliff G.; Culberson, Wesley S.; DeWerd, Larry A. [Department of Medical Physics, University of Wisconsin–Madison, Madison, Wisconsin 53705 (United States); Rostelato, Maria Elisa C. M.; Zeituni, Carlos A. [Instituto de Pesquisas Energéticas e Nucleares—IPEN-CNEN/SP, São Paulo 05508-000 (Brazil)

    2015-04-15

    Purpose: This work presents the development of a phantom to verify the treatment planning system (TPS) algorithms used for high-dose-rate (HDR) brachytherapy. It is designed to measure the relative dose in a heterogeneous media. The experimental details used, simulation methods, and comparisons with a commercial TPS are also provided. Methods: To simulate heterogeneous conditions, four materials were used: Virtual Water™ (VM), BR50/50™, cork, and aluminum. The materials were arranged in 11 heterogeneity configurations. Three dosimeters were used to measure the relative response from a HDR {sup 192}Ir source: TLD-100™, Gafchromic{sup ®} EBT3 film, and an Exradin™ A1SL ionization chamber. To compare the results from the experimental measurements, the various configurations were modeled in the PENELOPE/penEasy Monte Carlo code. Images of each setup geometry were acquired from a CT scanner and imported into BrachyVision™ TPS software, which includes a grid-based Boltzmann solver Acuros™. The results of the measurements performed in the heterogeneous setups were normalized to the dose values measured in the homogeneous Virtual Water™ setup and the respective differences due to the heterogeneities were considered. Additionally, dose values calculated based on the American Association of Physicists in Medicine-Task Group 43 formalism were compared to dose values calculated with the Acuros™ algorithm in the phantom. Calculated doses were compared at the same points, where measurements have been performed. Results: Differences in the relative response as high as 11.5% were found from the homogeneous setup when the heterogeneous materials were inserted into the experimental phantom. The aluminum and cork materials produced larger differences than the plastic materials, with the BR50/50™ material producing results similar to the Virtual Water™ results. Our experimental methods agree with the PENELOPE/penEasy simulations for most setups and dosimeters. The

  16. High-Dose-Rate Brachytherapy Boost Effect on Local Tumor Control in Young Women With Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Guinot, Jose-Luis, E-mail: jguinot@fivo.org [Department of Radiation Oncology, Fundacion Instituto Valenciano de Oncologia, Valencia (Spain); Baixauli-Perez, Cristobal [Health Services Research Unit, Center for Public Health Research, Valencia (Spain); Soler, Pablo; Tortajada, Maria Isabel; Moreno, Araceli; Santos, Miguel Angel; Mut, Alejandro [Department of Radiation Oncology, Fundacion Instituto Valenciano de Oncologia, Valencia (Spain); Gozalbo, Francisco [Department of Pathology, Fundacion Instituto Valenciano de Oncologia, Valencia (Spain); Arribas, Leoncio [Department of Radiation Oncology, Fundacion Instituto Valenciano de Oncologia, Valencia (Spain)

    2015-01-01

    Purpose: To evaluate the local control rate and complications of a single fraction of high-dose-rate brachytherapy (HDR BT) boost in women aged 45 yeas and younger after breast-conserving therapy. Methods and Materials: Between 1999 and 2007, 167 patients between the ages of 26 and 45 years old (72 were 40 years old or younger), with stages T1 to T2 invasive breast cancer with disease-free margin status of at least 5 mm after breast-conserving surgery received 46 to 50 Gy whole-breast irradiation plus a 7-Gy HDR-BT boost (“fast boost”). An axillary dissection was performed in 72.5% of the patients and sentinel lymph node biopsy in 27.5%. A supraclavicular area was irradiated in 19% of the patients. Chemotherapy was used in 86% of the patients and hormone treatment in 77%. Clinical nodes were present in 18% and pathological nodes in 29%. The pathological stage was pT0: 5%, pTis: 3%, pT1: 69% and pT2: 23%. Intraductal component was present in 40% and 28% were G3. Results: At a median follow-up of 92 months, 9 patients relapsed on the margin of the implant, and 1 patient in another quadrant, resulting in a 10-year local relapse rate of 4.3% and a breast relapse rate of 4.9%, with breast preservation in 93.4%; no case of mastectomy due to poor cosmesis arose. Actuarial 5- and 10-year disease-free, cause-specific, and overall survival rates were 87.9% and 85.8%, and 92.1% and 88.4%, and 92.1% and 87.3%, respectively. In a univariate analysis, triple-negative cases and negative hormone receptors did worse, but in a multivariate analysis, only the last factor was significant for local and breast control. Asymptomatic fibrosis G2 was recorded in 3 cases, and there were no other late complications. Cosmetic results were good to excellent in 97% of cases. Conclusions: A single dose of 7 Gy using the fast-boost technique is well tolerated, with a low rate of late complications and improved local tumor control in women aged 45 and younger, compared to published data

  17. Commissioning of a 3D image-based treatment planning system for high-dose-rate brachytherapy of cervical cancer.

    Science.gov (United States)

    Kim, Yongbok; Modrick, Joseph M; Pennington, Edward C; Kim, Yusung

    2016-03-08

    The objective of this work is to present commissioning procedures to clinically implement a three-dimensional (3D), image-based, treatment-planning system (TPS) for high-dose-rate (HDR) brachytherapy (BT) for gynecological (GYN) cancer. The physical dimensions of the GYN applicators and their values in the virtual applicator library were varied by 0.4 mm of their nominal values. Reconstruction uncertainties of the titanium tandem and ovoids (T&O) were less than 0.4 mm on CT phantom studies and on average between 0.8-1.0 mm on MRI when compared with X-rays. In-house software, HDRCalculator, was developed to check HDR plan parameters such as independently verifying active tandem or cylinder probe length and ovoid or cylinder size, source calibration and treatment date, and differences between average Point A dose and prescription dose. Dose-volume histograms were validated using another independent TPS. Comprehensive procedures to commission volume optimization algorithms and process in 3D image-based planning were presented. For the difference between line and volume optimizations, the average absolute differences as a percentage were 1.4% for total reference air KERMA (TRAK) and 1.1% for Point A dose. Volume optimization consistency tests between versions resulted in average absolute differences in 0.2% for TRAK and 0.9 s (0.2%) for total treatment time. The data revealed that the optimizer should run for at least 1 min in order to avoid more than 0.6% dwell time changes. For clinical GYN T&O cases, three different volume optimization techniques (graphical optimization, pure inverse planning, and hybrid inverse optimization) were investigated by comparing them against a conventional Point A technique. End-to-end testing was performed using a T&O phantom to ensure no errors or inconsistencies occurred from imaging through to planning and delivery. The proposed commissioning procedures provide a clinically safe implementation technique for 3D image-based TPS for HDR

  18. Dosimetric evaluation of multilumen intracavitary balloon applicator rotation in high-dose-rate brachytherapy for breast cancer.

    Science.gov (United States)

    Kim, Yongbok; Trombetta, Mark G

    2014-01-06

    The objective of this work is to evaluate dosimetric impact of multilumen balloon applicator rotation in high-dose-rate (HDR) brachytherapy for breast cancer. Highly asymmetrical dose distribution was generated for patients A and B, depending upon applicator proximity to skin and rib. Both skin and rib spacing was ≤ 0.7 cm for A; only rib spacing was ≤ 0.7 cm for B. Thirty-five rotation scenarios were simulated for each patient by rotating outer lumens every 10° over ± 180° range with respect to central lumen using mathematically calculated rotational matrix. Thirty-five rotated plans were compared with three plans: 1) original multidwell multilumen (MDML) plan, 2) multidwell single-lumen (MDSL) plan, and 3) single-dwell single-lumen (SDSL) plan. For plan comparison, planning target volume for evaluation (PTV_EVAL) coverage (dose to 95% and 90% volume of PTV_EVAL) (D95 and D90), skin and rib maximal dose (Dmax), and normal breast tissue volume receiving 150% (V150) and 200% (V200) of prescribed dose (PD) were evaluated. Dose variation due to device rotation ranged from -5.6% to 0.8% (A) and -6.5% to 0.2% (B) for PTV_EVAL D95; -5.2% to 0.4% (A) and -4.1% to 0.7% (B) for PTV_EVAL D90; -2.0 to 18.4% (A) and -7.8 to 17.5% (B) for skin Dmax; -11.1 to 22.8% (A) and -4.7 to 55.1% (B) of PD for rib Dmax, respectively. Normal breast tissue V150 and V200 variation was < 1.0 cc, except for -0.1 to 2.5cc (B) of V200. Furthermore, 30° device rotation increased rib Dmax over 145% of PD: 152.9% (A) by clockwise 30° rotation and 152.5% (B) by counterclockwise 30° rotation. For a highly asymmetric dose distribution, device rotation can outweigh the potential benefit of improved dose shaping capability afforded by multilumen and make dosimetric data worse than single-lumen plans unless it is properly corrected.

  19. Investigations of DNA damage induction and repair resulting from cellular exposure to high dose-rate pulsed proton beams

    Energy Technology Data Exchange (ETDEWEB)

    Renis, M.; Malfa, G.; Tomasello, B. [Drug Sciences Department, University of Catania, Catania (Italy); Borghesi, M.; Schettino, G. [Queen' s University Belfast, Northern Ireland (United Kingdom); Favetta, M.; Romano, F.; Cirrone, G. A. P. [National Institute for Nuclear Physics (INFN-LNS), Catania (Italy); Manti, L. [Physics Science Department, University of Naples Federico II, Naples, and National Institute for Nuclear Physics (INFN), Naples (Italy)

    2013-07-26

    Studies regarding the radiobiological effects of low dose radiation, microbeam irradiation services have been developed in the world and today laser acceleration of protons and heavy ions may be used in radiation therapy. The application of different facilities is essential for studying bystander effects and relating signalling phenomena in different cells or tissues. In particular the use of ion beams results advantageous in cancer radiotherapy compared to more commonly used X-rays, since the ability of ions in delivering lethal amount of doses into the target tumour avoiding or limiting damage to the contiguous healthy tissues. At the INFN-LNS in Catania, a multidisciplinary radiobiology group is strategically structured aimed to develop radiobiological research, finalised to therapeutic applications, compatible with the use of high dose laser-driven ion beams. The characteristic non-continuous dose rates with several orders of magnitude of laser-driven ion beams makes this facility very interesting in the cellular systems' response to ultra-high dose rates with non-conventional pulse time intervals cellular studies. Our group have projected to examine the effect of high dose laser-driven ion beams on two cellular types: foetal fibroblasts (normal control cells) and DU145 (prostate cancer cells), studying the modulation of some different bio-molecular parameters, in particular cell proliferation and viability, DNA damage, redox cellular status, morphological alterations of both the cytoskeleton components and some cell organelles and the possible presence of apoptotic or necrotic cell death. Our group performed preliminary experiments with high energy (60 MeV), dose rate of 10 Gy/min, doses of 1, 2, 3 Gy and LET 1 keV/μm on human foetal fibroblasts (control cells). We observed that cell viability was not influenced by the characteristics of the beam, the irradiation conditions or the analysis time. Conversely, DNA damage was present at time 0, immediately

  20. A novel adaptive needle insertion sequencing for robotic, single needle MR-guided high-dose-rate prostate brachytherapy

    Science.gov (United States)

    Borot de Battisti, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; Maenhout, M.; Moerland, M. A.

    2017-05-01

    MR-guided high-dose-rate (HDR) brachytherapy has gained increasing interest as a treatment for patients with localized prostate cancer because of the superior value of MRI for tumor and surrounding tissues localization. To enable needle insertion into the prostate with the patient in the MR bore, a single needle MR-compatible robotic system involving needle-by-needle dose delivery has been developed at our institution. Throughout the intervention, dose delivery may be impaired by: (1) sub-optimal needle positioning caused by e.g. needle bending, (2) intra-operative internal organ motion such as prostate rotations or swelling, or intra-procedural rectum or bladder filling. This may result in failure to reach clinical constraints. To assess the first aforementioned challenge, a recent study from our research group demonstrated that the deposited dose may be greatly improved by real-time adaptive planning with feedback on the actual needle positioning. However, the needle insertion sequence is left to the doctor and therefore, this may result in sub-optimal dose delivery. In this manuscript, a new method is proposed to determine and update automatically the needle insertion sequence. This strategy is based on the determination of the most sensitive needle track. The sensitivity of a needle track is defined as its impact on the dose distribution in case of sub-optimal positioning. A stochastic criterion is thus presented to determine each needle track sensitivity based on needle insertion simulations. To assess the proposed sequencing strategy, HDR prostate brachytherapy was simulated on 11 patients with varying number of needle insertions. Sub-optimal needle positioning was simulated at each insertion (modeled by typical random angulation errors). In 91% of the scenarios, the dose distribution improved when the needle was inserted into the most compared to the least sensitive needle track. The computation time for sequencing was less than 6 s per needle track. The

  1. HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

    Energy Technology Data Exchange (ETDEWEB)

    Chibani, Omar, E-mail: omar.chibani@fccc.edu; C-M Ma, Charlie [Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States)

    2014-05-15

    Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR

  2. CT-guided high-dose-rate brachytherapy in the interdisciplinary treatment of patients with liver metastases of pancreatic cancer.

    Science.gov (United States)

    Wieners, Gero; Schippers, Alexander Christian; Collettini, Federico; Schnapauff, Dirk; Hamm, Bernd; Wust, Peter; Riess, Hanno; Gebauer, Bernhard

    2015-10-01

    CT-guided high-dose-rate brachytherapy (CT-HDRBT) is an interventional radiologic technique for local ablation of primary and secondary malignomas applying a radiation source through a brachycatheter percutaneously into the targeted lesion. The aim of this study was to assess local tumor control, safety and efficacy of CT-HDRBT in the treatment of liver metastases of pancreatic cancer. Twenty consecutive patients with 49 unresectable liver metastases of pancreatic cancer were included in this retrospective trial and treated with CT-HDRBT, applied as a single fraction high-dose irradiation (15-20 Gy) using a 192Ir-source. Primary endpoint was local tumor control and secondary endpoints were complications, progression-free survival and overall survival. The mean tumor diameter was 29 mm (range 10-73). The mean irradiation time was 20 minutes (range 7-42). The mean coverage of the clinical target volume was 98% (range 88%-100%). The mean D100 was 18.1 Gy and the median D100 was 19.78 Gy. Three major complications occurred with post-interventional abscesses, three of which were seen in 15 patients with biliodigestive anastomosis (20%) and overall 15%. The mean follow-up time was 13.7 months (range 1.4-55.0). The median progression-free survival was 4.9 months (range 1.4-42.9, mean 9.4). Local recurrence occurred in 5 (10%) of 49 metastases treated. The median overall survival after CT-HDRBT was 8.6 months (range 1.5-55.3). Eleven patients received chemotherapy after ablation with a median progression-free survival of 4.9 months (mean 12.9). Nine patients did not receive chemotherapy after intervention with a median progression-free survival of 3.2 months (mean 5.0). The rate of local tumor control was 91% in both groups after 12 months. CT-HDRBT was safe and effective for the treatment of liver metastases of pancreatic cancer.

  3. Image guided radiation therapy boost in combination with high-dose-rate intracavitary brachytherapy for the treatment of cervical cancer

    Directory of Open Access Journals (Sweden)

    Xianliang Wang

    2016-04-01

    Full Text Available Purpose : The purpose of this study was to demonstrate the dosimetric and clinical feasibility of image guided radiation therapy (IGRT combined with high-dose-rate (HDR intracavitary brachytherapy (ICBT to improve dose distribution in cervical cancer treatment. Material and methods: For 42 cervical cancer patients, magnetic resonance imaging (MRI scans were acquired after completion of whole pelvic irradiation 45-46 Gy and 5 fractions of B + I (ICBT + IGRT treatment were subsequently received. The high risk clinical target volume (HRCTV, intermediate risk clinical target volume (IRCTV, bladder, rectum, and sigmoid were contoured on the computed tomography (CT scans. The total planning aim doses for HRCTV was D 90% > 85 Gy, whilst constraints for rectum and sigmoid were D 2cc < 75 Gy and D 2cc < 90 Gy for bladder in terms of an equivalent dose in 2 Gy (EQD2 for external beam radiotherapy (EBRT and brachytherapy boost. The IGRT plan was optimized on top of the ICBT dose distribution. A dosimetric comparison was made between B + I and optimized ICBT (O-ICBT only. Results: The mean D 90% of HRCTV was comparable for B + I and O-ICBT (p = 0.82. For B + I plan, HRCTV D100%, IRCTV D 100% , and IRCTV D 90% were significantly increased by a mean of 10.52 Gy, 5.61 Gy, and 2.70 Gy, respectively (p < 0.01. The D 2cc for bladder, rectum, and sigmoid were lower by a mean of 21.36, 6.78, and 10.65 Gy, respectively (p < 0.01. The mean rectum V60 Gy value over 42 patients was almost the same for both techniques but for bladder and sigmoid B + I had higher V60 Gy mean values as compared with the O-ICBT. Conclusions : B + I can improve dose distribution in cervical cancer treatment; it could be useful for tumors extended beyond the reach of intracavitary/interstitial brachytherapy (IC/ISBT or for centers that are inexperienced or ill-equipped with IC/ISBT techniques. Additional confirmatory prospective studies with larger numbers of patients and longer follow

  4. Effect of rectal enemas on rectal dosimetric parameters during high-dose-rate vaginal cuff brachytherapy. A prospective trial

    Energy Technology Data Exchange (ETDEWEB)

    Sabater, Sebastia; Andres, Ignacio; Sevillano, Marimar; Berenguer, Roberto; Aguayo, Manuel; Villas, Maria Victoria [Complejo Hospitalario Universitario de Albacete (CHUA), Department of Radiation Oncology, Albacete (Spain); Gascon, Marina; Arenas, Meritxell [Hospital Universitari Sant Joan, Department of Radiation Oncology, Reus (Spain); Rovirosa, Angeles; Camacho-Lopez, Cristina [University of Barcelona, IDIBAPS, Gynecological Cancer Unit, Radiation Oncology Department, ICMHO, Hospital Clinic, Barcelona (Spain)

    2016-04-15

    To evaluate the effects of rectal enemas on rectal doses during postoperative high-dose-rate (HDR) vaginal cuff brachytherapy (VCB). This prospective trial included 59 patients. Two rectal cleansing enemas were self-administered before the second fraction, and fraction 1 was considered the basal status. Dose-volume histogram (DVH) values were generated for the rectum and correlated with rectal volume variation. Statistical analyses used paired and unpaired t-tests. Despite a significant 15 % reduction in mean rectal volume (44.07 vs. 52.15 cc, p = 0.0018), 35.6 % of patients had larger rectums after rectal enemas. No significant rectal enema-related DVH differences were observed compared to the basal data. Although not statistically significant, rectal cleansing-associated increases in mean rectal DVH values were observed: D{sub 0.1} {sub cc}: 6.6 vs. 7.21 Gy; D{sub 1} {sub cc}: 5.35 vs. 5.52 Gy; D{sub 2} {sub cc}: 4.67 vs. 4.72 Gy, before and after rectal cleaning, respectively (where D{sub x} {sub cc} is the dose to the most exposed x cm {sup 3}). No differences were observed in DVH parameters according to rectal volume increase or decrease after the enema. Patients whose rectal volume increased also had significantly larger DVH parameters, except for D{sub 5} {sub %}, D{sub 25} {sub %}, and D{sub 50} {sub %}. In contrast, in patients whose rectal volume decreased, significance was only seen for D{sub 25} {sub %} and D{sub 50} {sub %} (D{sub x} {sub %} dose covering x % of the volume). In the latter patients, nonsignificant reductions in D{sub 2} {sub cc}, D{sub 5} {sub cc} and V{sub 5} {sub Gy} (volume receiving at least 5 Gy) were observed. The current rectal enemas protocol was ineffective in significantly modifying rectal DVH parameters for HDR-VCB. (orig.) [German] Beurteilung der Auswirkungen von rektalen Dosen waehrend postoperativer High-Dose-Rate-(HDR-)Brachytherapie an der Scheidenmanschette (''vaginal cuff brachytherapy'', VCB). An

  5. Comparison BIPM.RI(I)-K8 of high dose-rate Ir-192 brachytherapy standards for reference air kerma rate of the VSL and the BIPM

    DEFF Research Database (Denmark)

    Alvarez, J.T.; De Pooter, J.A.; Andersen, Claus E.

    2014-01-01

    An indirect comparison of the standards for reference air kerma rate for 192Ir high dose rate brachytherapy sources of the Dutch Metrology Institute (VSL), The Netherlands, and of the Bureau International des Poids et Mesures (BIPM) was carried out at the VSL in November 2009. The comparison resu...

  6. Toward a 3D transrectal ultrasound system for verification of needle placement during high-dose-rate interstitial gynecologic brachytherapy.

    Science.gov (United States)

    Rodgers, Jessica Robin; Surry, Kathleen; Leung, Eric; D'Souza, David; Fenster, Aaron

    2017-05-01

    Treatment for gynecologic cancers, such as cervical, recurrent endometrial, and vaginal malignancies, commonly includes external-beam radiation and brachytherapy. In high-dose-rate (HDR) interstitial gynecologic brachytherapy, radiation treatment is delivered via hollow needles that are typically inserted through a template on the perineum with a cylinder placed in the vagina for stability. Despite the need for precise needle placement to minimize complications and provide optimal treatment, there is no standard intra-operative image-guidance for this procedure. While some image-guidance techniques have been proposed, including magnetic resonance (MR) imaging, X-ray computed tomography (CT), and two-dimensional (2D) transrectal ultrasound (TRUS), these techniques have not been widely adopted. In order to provide intra-operative needle visualization and localization during interstitial brachytherapy, we have developed a three-dimensional (3D) TRUS system. This study describes the 3D TRUS system and reports on the system validation and results from a proof-of-concept patient study. To obtain a 3D TRUS image, the system rotates a conventional 2D endocavity transducer through 170 degrees in 12 s, reconstructing the 2D frames into a 3D image in real-time. The geometry of the reconstruction was validated using two geometric phantoms to ensure the accuracy of the linear measurements in each of the image coordinate directions and the volumetric accuracy of the system. An agar phantom including vaginal and rectal canals, as well as a model uterus and tumor, was designed and used to test the visualization and localization of the interstitial needles under idealized conditions by comparing the needles' positions between the 3D TRUS scan and a registered MR image. Five patients undergoing HDR interstitial gynecologic brachytherapy were imaged using the 3D TRUS system following the insertion of all needles. This image was manually, rigidly registered to the clinical

  7. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Ken; Mitomo, Masanori [Osaka National Hospital (Japan); Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji [Osaka Prefectural Center for Adult Diseases (Japan); Yoshida, Mineo [Sanda City Hospital, Hyogo (Japan)

    2002-12-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients

  8. Tandem-ring dwell time ratio in Nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer

    OpenAIRE

    2015-01-01

    Purpose In high-dose-rate (HDR) brachytherapy (BT), the source dwell times and dwell positions are essential treatment planning parameters. An optimal choice of these factors is fundamental to obtain the desired target coverage with the lowest achievable dose to the organs at risk (OARs). This study evaluates relevant dose parameters in cervix brachytherapy in order to assess existing tandem-ring dwell time ratio used at the first HDR BT center in Nigeria, and compare it with an alternative s...

  9. Afterloading: The Technique That Rescued Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Aronowitz, Jesse N., E-mail: jesse.aronowitz@umassmemorial.org

    2015-07-01

    Although brachytherapy had been established as a highly effective modality for the treatment of cancer, its application was threatened by mid-20th century due to appreciation of the radiation hazard to health care workers. This review examines how the introduction of afterloading eliminated exposure and ushered in a brachytherapy renaissance.

  10. Medically inoperable endometrial cancer in patients with a high body mass index (BMI): Patterns of failure after 3-D image-based high dose rate (HDR) brachytherapy

    DEFF Research Database (Denmark)

    Acharya, Sahaja; Esthappan, Jacqueline; Badiyan, Shahed

    2016-01-01

    BACKGROUND AND PURPOSE: High BMI is a reason for medical inoperability in patients with endometrial cancer in the United States. Definitive radiation is an alternative therapy for these patients; however, data on patterns of failure after definitive radiotherapy are lacking. We describe...... the patterns of failure after definitive treatment with 3-D image-based high dose rate (HDR) brachytherapy for medically inoperable endometrial cancer. MATERIALS AND METHODS: Forty-three consecutive patients with endometrial cancer FIGO stages I-III were treated definitively with HDR brachytherapy...

  11. Daily computed tomography measurement of needle applicator displacement during high-dose-rate interstitial brachytherapy for previously untreated uterine cervical cancer.

    Science.gov (United States)

    Mikami, Mari; Yoshida, Ken; Takenaka, Tadashi; Yamazaki, Hideya; Kotsuma, Tadayuki; Yoshida, Mineo; Aramoto, Kazumasa; Yamada, Shigetoshi; Ban, Chiaki; Tanaka, Eiichi; Honda, Kazuya

    2011-01-01

    We investigated daily needle applicator displacement during high-dose-rate interstitial brachytherapy. Ten patients with previously untreated uterine cervical cancer received 30Gy in five fractions during 3 days of high-dose-rate interstitial brachytherapy combined with external beam radiotherapy using our unique ambulatory technique. To analyze displacement, we obtained daily computed tomography (CT) images for 147 flexible needle applicators at 21 and 45h after implantation. The distance was defined as the length between the center of gravity of titanium markers and the needle applicator tips along the daily CT axis. We adapted dwell positions of the treatment source to cover clinical target volume with a 15-mm cranial margin. The median displacement was 1mm (range, -6 to 12mm) at 21h and 2mm (range, -9 to 14mm) at 45h, respectively. Statistically significant caudal displacement was observed only between the displacement at 0 and 21h (pBrachytherapy Society. Published by Elsevier Inc. All rights reserved.

  12. High-dose rate iridium-192 brachytherapy with flexible applicator. A trial toward decrease of stress during treatment and improvement of quality of life

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Keiji; Kasahara, Kotaro; Karashima, Takashi; Inoue, Yuichiro; Kariya, Shinji; Inomata, Taisuke; Yoshida, Shoji; Shuin, Taro [Kochi Medical School, Nankoku (Japan)

    2001-07-01

    We tried to improve the materials and methods of high-dose rate Iridium-192 brachytherapy for localized prostate cancer and evaluated the stress during the treatment in 20 patients with whom the therapy was performed. Rigid applicators made of stainless steel of 1.6 mm in diameter were indwelt with a template as usual for 30 hours in 14 patients (group A). Flexible applicators made of polyoxymethylene rosin (POM) of 2.0 mm in diameter were indwelt without a template for 30 hours after the applicator insertion in 6 patients (group B). We made inquiries about lumbago, inconvenience and necessity of assistant help and sleep in the course of therapy, and urinary incontinence and erectile function after the course of therapy as the QOL. The stress during the course of therapy in the patients of group B was obviously less than that of group A. There were no significant differences in urinary incontinence and erectile function after the course of therapy between group A and B. In this study, our trial successfully reduced the stress during the course of therapy in the patients with localized prostate cancer in the course of high-dose rate Iridium-192 brachytherapy. (author)

  13. Spontaneous intraluminal migration of gossypiboma

    Directory of Open Access Journals (Sweden)

    Sebastian Saji

    2011-01-01

    Full Text Available Retained surgical mops following surgery is an avoidable but serious complication. They are seldom reported because of medicolegal implications but clinicians need to be aware about varied presentations of this entity to avoid unnecessary morbidity. We report a case of a 28-year-old woman who presented with chronic diarrhea and lower abdominal pain due to intraluminal migration of the surgical mop into the sigmoid colon 6 months after myomectomy of the uterus. The possibility of gossypiboma was suggested by the contrast-enhanced CT scan of the abdomen. Flexible sigmoidosocpy showed the remnants of the mop inside the lumen of the sigmoid colon. She underwent laparotomy and removal of the surgical mop and became completely asymptomatic. Though gossypiboma is rare clinicians should keep it in mind in patients who had undergone laparotomy previously.

  14. Intraluminal tissue welding for anastomosis

    Science.gov (United States)

    Glinsky, Michael; London, Richard; Zimmerman, George; Jacques, Steven

    1998-10-27

    A method and device are provided for performing intraluminal tissue welding for anastomosis of a hollow organ. A retractable catheter assembly is delivered through the hollow organ and consists of a catheter connected to an optical fiber, an inflatable balloon, and a biocompatible patch mounted on the balloon. The disconnected ends of the hollow organ are brought together on the catheter assembly, and upon inflation of the balloon, the free ends are held together on the balloon to form a continuous channel while the patch is deployed against the inner wall of the hollow organ. The ends are joined or "welded" using laser radiation transmitted through the optical fiber to the patch. A thin layer of a light-absorbing dye on the patch can provide a target for welding. The patch may also contain a bonding agent to strengthen the bond. The laser radiation delivered has a pulse profile to minimize tissue damage.

  15. American Society for Radiation Oncology (ASTRO) and American College of Radiology (ACR) practice guideline for the performance of high-dose-rate brachytherapy.

    Science.gov (United States)

    Erickson, Beth A; Demanes, D Jeffrey; Ibbott, Geoffrey S; Hayes, John K; Hsu, I-Chow J; Morris, David E; Rabinovitch, Rachel A; Tward, Jonathan D; Rosenthal, Seth A

    2011-03-01

    High-Dose-Rate (HDR) brachytherapy is a safe and efficacious treatment option for patients with a variety of different malignancies. Careful adherence to established standards has been shown to improve the likelihood of procedural success and reduce the incidence of treatment-related morbidity. A collaborative effort of the American College of Radiology (ACR) and American Society for Therapeutic Radiation Oncology (ASTRO) has produced a practice guideline for HDR brachytherapy. The guideline defines the qualifications and responsibilities of all the involved personnel, including the radiation oncologist, physicist and dosimetrists. Review of the leading indications for HDR brachytherapy in the management of gynecologic, thoracic, gastrointestinal, breast, urologic, head and neck, and soft tissue tumors is presented. Logistics with respect to the brachytherapy implant procedures and attention to radiation safety procedures and documentation are presented. Adherence to these practice guidelines can be part of ensuring quality and safety in a successful HDR brachytherapy program.

  16. Preventing Complications from High-Dose Rate Brachytherapy when Treating Mobile Tongue Cancer via the Application of a Modular Lead-Lined Spacer.

    Directory of Open Access Journals (Sweden)

    Shumei Murakami

    Full Text Available To point out the advantages and drawbacks of high-dose rate brachytherapy in the treatment of mobile tongue cancer and indicate the clinical importance of modular lead-lined spacers when applying this technique to patients.First, all basic steps to construct the modular spacer are shown. Second, we simulate and evaluate the dose rate reduction for a wide range of spacer configurations.With increasing distance to the source absorbed doses dropped considerably. Significantly more shielding was obtained when lead was added to the spacer and this effect was most pronounced on shorter (i.e. more clinically relevant distances to the source.The modular spacer represents an important addition to the planning and treatment stages of mobile tongue cancer using HDR-ISBT.

  17. Preventing Complications from High-Dose Rate Brachytherapy when Treating Mobile Tongue Cancer via the Application of a Modular Lead-Lined Spacer.

    Science.gov (United States)

    Murakami, Shumei; Verdonschot, Rinus G; Kakimoto, Naoya; Sumida, Iori; Fujiwara, Masateru; Ogawa, Kazuhiko; Furukawa, Souhei

    2016-01-01

    To point out the advantages and drawbacks of high-dose rate brachytherapy in the treatment of mobile tongue cancer and indicate the clinical importance of modular lead-lined spacers when applying this technique to patients. First, all basic steps to construct the modular spacer are shown. Second, we simulate and evaluate the dose rate reduction for a wide range of spacer configurations. With increasing distance to the source absorbed doses dropped considerably. Significantly more shielding was obtained when lead was added to the spacer and this effect was most pronounced on shorter (i.e. more clinically relevant) distances to the source. The modular spacer represents an important addition to the planning and treatment stages of mobile tongue cancer using HDR-ISBT.

  18. Preventing Complications from High-Dose Rate Brachytherapy when Treating Mobile Tongue Cancer via the Application of a Modular Lead-Lined Spacer

    Science.gov (United States)

    Murakami, Shumei; Verdonschot, Rinus G.; Kakimoto, Naoya; Sumida, Iori; Fujiwara, Masateru; Ogawa, Kazuhiko; Furukawa, Souhei

    2016-01-01

    Purpose To point out the advantages and drawbacks of high-dose rate brachytherapy in the treatment of mobile tongue cancer and indicate the clinical importance of modular lead-lined spacers when applying this technique to patients. Methods First, all basic steps to construct the modular spacer are shown. Second, we simulate and evaluate the dose rate reduction for a wide range of spacer configurations. Results With increasing distance to the source absorbed doses dropped considerably. Significantly more shielding was obtained when lead was added to the spacer and this effect was most pronounced on shorter (i.e. more clinically relevant) distances to the source. Conclusions The modular spacer represents an important addition to the planning and treatment stages of mobile tongue cancer using HDR-ISBT. PMID:27128434

  19. Percutaneous computed tomography-guided high-dose-rate brachytherapy ablation of breast cancer liver metastases: initial experience with 80 lesions.

    Science.gov (United States)

    Collettini, Federico; Golenia, Mascha; Schnapauff, Dirk; Poellinger, Alexander; Denecke, Timm; Wust, Peter; Riess, Hanno; Hamm, Bernd; Gebauer, Bernhard

    2012-05-01

    To analyze initial experience with computed tomography-guided high-dose-rate brachytherapy (CT-HDRBT) ablation of breast cancer liver metastases (BCLM). Between January 2008 and December 2010, 37 consecutive women with 80 liver metastases were treated with CT-HDRBT in 56 sessions. Mean age was 58.6 years (range, 34-83 y). Treatment was performed by CT-guided applicator placement and high-dose-rate brachytherapy with an iridium-192 source. The mean radiation dose was 18.57 Gy (standard deviation 2.27). Tumor response was evaluated by gadoxetic acid-enhanced liver magnetic resonance (MR) imaging performed before treatment, 6 weeks after treatment, and every 3 months thereafter. Two patients were lost to follow-up; the remaining 35 patients were available for MR imaging evaluation for a mean follow-up time of 11.6 months (range 3-32 mo). Mean tumor diameter was 25.5 mm (range 8-74 mm). Two (2.6%) local recurrences were observed after local tumor control for 10 months and 12 months. Both local progressions were successfully retreated. Distant tumor progression (new metastases or enlargement of nontreated metastases) occurred during the follow-up period in 11 (31.4%) patients. Seven (20%) patients died during the follow-up period. Overall survival ranged from 3-39 months (median 18 months). CT-HDRBT is a safe and effective ablative therapy, providing a high rate of local tumor control in patients with BCLM. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  20. Dosimetric analysis of Co-60 source based high dose rate (HDR) brachytherapy: A case series of ten patients with carcinoma of the uterine cervix.

    Science.gov (United States)

    Gurjar, Om Prakash; Batra, Manika; Bagdare, Priyusha; Kaushik, Sandeep; Tyagi, Atul; Naik, Ayush; Bhandari, Virendra; Gupta, Krishna Lal

    2016-01-01

    To analyse the dosimetric parameters of Co-60 based high dose rate (HDR) brachytherapy plans for patients of carcinoma uterine cervix. Co-60 high dose rate (HDR) brachytherapy unit has been introduced in past few years and is gaining importance owing to its long half life, economical benefits and comparable clinical outcome compared to Ir-192 HDR brachytherapy. A study was conducted on ten patients with locally advanced carcinoma of the uterine cervix (Ca Cx). Computed tomography (CT) images were taken after three channel applicator insertions. The planning for 7 Gray per fraction (7 Gy/#) was done for Co-60 HDR brachytherapy unit following the American Brachytherapy Society (ABS) guidelines. All the patients were treated with 3# with one week interval between fractions. The mean dose to high risk clinical target volumes (HRCTV) for D90 (dose to 90% volume) was found to be 102.05% (Standard Deviation (SD): 3.07). The mean D2cc (dose to 2 cubic centimeter volume) of the bladder, rectum and sigmoid were found to be 15.9 Gy (SD: 0.58), 11.5 Gy (SD: 0.91) and 4.1 Gy (SD: 1.52), respectively. The target coverage and doses to organs at risk (OARs) were achieved as per the ABS guidelines. Hence, it can be concluded that the Co-60 HDR brachytherapy unit is a good choice especially for the centers with a small number of brachytherapy procedures as no frequent source replacement is required like in an Ir-192 HDR unit.

  1. SU-D-BRE-04: Evaluating the Dose Accuracy of a 2D Ion Chamber Array in High Dose Rate Pencil Beam Scanning Proton Beam

    Energy Technology Data Exchange (ETDEWEB)

    Perles, L; Mascia, A; Piskulich, F; Lepage, R; Zhang, Y; Giebeler, A; Dong, L [Scripps Proton Therapy Center, San Diego, CA (United States)

    2014-06-01

    Purpose: To evaluate the absolute dose accuracy of the PTW Octavius 729 XDR 2D ion chamber array at a high dose rate pencil beam scanning proton therapy facility. Methods: A set of 18 plans were created in our treatment planning system, each of which comprising a unique combination of field sizes (FS), length of spread out of Bragg peaks (SOBP) and depths. The parameters used were: FS of 5×5cm{sup 2}, 10×10cm{sup 2} and 15×15cm{sup 2}; flat SOBP of 5cm and 10cm; and isocenter depths of 10cm, 15cm and 20cm, which coincides with the center of the SOBP. The 2D array detector was positioned at the machine isocenter and the appropriate amount of solid water was used to match the planned depths of 10, 15 and 20 cm water equivalent depth. Subsequently, we measured the absolute dose at isocenter using a CC04 ion chamber in a 1D water tank. Both 2D array and CC04 were previously cross calibrated. We also collected the MU rates used by our proton machine from the log files. Results: The relative differences between the CC04 and the 2D array can be summarized into two groups, one with 5 cm SOBP and another with 10 cm SOBP. Plotting these datasets against FS shows that the 2D array response for high dose rate fields (FS of 5×5cm{sup 2} and 5cm SOBP) can be up to 2% lower. Similarly, plotting them against isocenter depths reveals the detector's response can be up to 2% lower for higher energy beams (about 200MeV nominal). The MU rate found in the machine log files for 5cm SOBP's were as high as twice the MU rate for the 10cm SOBP. Conclusion: The 2D array dose response showed a dose rate effect in scanning pencil beam delivery, which needs to be corrected to achieve a better dose accuracy.

  2. Outcomes of salvage high-dose-rate brachytherapy with or without external beam radiotherapy for isolated vaginal recurrence of endometrial cancer.

    Science.gov (United States)

    Sekii, Shuhei; Murakami, Naoya; Kato, Tomoyasu; Harada, Ken; Kitaguchi, Mayuka; Takahashi, Kana; Inaba, Koji; Igaki, Hiroshi; Ito, Yoshinori; Sasaki, Ryohei; Itami, Jun

    2017-06-01

    This study was designed to retrospectively analyze outcomes of high-dose-rate (HDR) brachytherapy, with or without external beam radiotherapy (EBRT), in patients with vaginal recurrence of endometrial carcinoma, and to identify factors prognostic of patient outcomes. The medical records of all patients who underwent HDR brachytherapy for initial recurrence in the vagina of endometrial cancer after definitive surgery between 1992 and 2014 were retrospectively reviewed. All patients underwent either intracavitary brachytherapy (ICBT) or interstitial brachytherapy (ISBT) with or without EBRT. Late toxicity was graded using the EORTC (LENT/SOMA) scale, revised in 1995. Thirty-seven patients were identified. The median follow-up time was 48 months (range: 6-225 months). Of these 37 patients, 23 underwent ICBT, 14 underwent ISBT, and 26 underwent EBRT. Tumor size at first examination of initial relapse was significantly larger in the ISBT than in the ICBT group. The 4-year respective overall survival (OS), local control (LC), and progression-free survival (PFS) rates in the entire cohort were 81.0%, 77.9%, and 56.8%, respectively. The interval between diagnosis of first recurrence and radiotherapy (endometrial carcinoma with acceptable morbidity. Early radiotherapy, including brachytherapy, should be considered for women who experience vaginal recurrence of endometrial cancer.

  3. Interstitial high-dose rate brachytherapy for recurrent cervical cancer after radiation therapy; Braquiterapia intersticial para recidivas de cancer de colo uterino pos-radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Antonio Carlos Zuliani de; Esteves, Sergio Carlos Barros; Feijo, Luiz Fernando Andrade; Tagawa, Eduardo Komai; Cunha, Maercio de Oliveira [Universidade Estadual de Campinas, SP (Brazil). Centro de Atencao Integral a Saude da Mulher (CAISM)]. E-mail: estevesrt@uol.com.br

    2005-04-01

    Objective: To evaluate the response and potential toxicity of fractionated interstitial high-dose rate (HDR) brachytherapy for post-radiation pelvic recurrence in cervical cancer. Materials And Methods: From 1998 to 2001, 11 patients aged 41 to 71 years with cervical carcinoma stages II to IV who presented pelvic recurrence after radiation therapy were treated wit interstitial HDR. Nine of these patients (82%) had squamous cell carcinoma and two had adenocarcinoma. Radiation consisted of 20 Gy to 30 Gy delivered in fractions of 4 Gy to 5 Gy over three days. The median follow-up was 22.5 months (2 to 54 months), with periodic physical examinations (three months interval). One patient died without evaluation of the response. Results: Ten patients (91%) presented complete clinical response, three patients (27%) were disease free, two were alive with disease, three (27%) died of cancer and three (27%) were lost in the follow-up after the second recurrence. Urinary tract toxicity grade III was 9% (one patient). Conclusion: Interstitial HDR brachytherapy is an alternative approach to selected patients with recurrent cervical carcinoma after radiation therapy. High response rates were achieved with low toxicity taking into account the studied group, time of follow-up and re-irradiation. (author)

  4. Dose reduction trial from 60 Gy in 10 fractions to 54 Gy in 9 fractions schedule in high-dose-rate interstitial brachytherapy for early oral tongue cancer

    Science.gov (United States)

    Akiyama, Hironori; Yoshida, Ken; Shimizutani, Kimishige; Yamazaki, Hideya; Koizumi, Masahiko; Yoshioka, Yasuo; Kakimoto, Naoya; Murakami, Shumei; Furukawa, Souhei; Ogawa, Kazuhiko

    2012-01-01

    To compare the effects of 60 Gy/10 fractions (twice a day) with those of 54 Gy/9 fractions in high-dose-rate interstitial brachytherapy (HDR-ISBT) for early tongue cancer, we performed a matched-pair analysis of patients with early tongue cancer (T1-2N0M0), who were treated with 60 or 54 Gy of radiation between 1996 and 2004. Seventeen patients treated with 54 Gy and 34 matched-pair patients treated with 60 Gy were extracted and analyzed. Local recurrence occurred in two patients in the 54-Gy arm and five patients in the 60-Gy arm. The 2-year local control rates were 88% for both the 54-Gy arm and 60-Gy arm (not significant). The 2-year overall survival rates were 88% in the 60-Gy arm and 82% in the 54-Gy arm. Two-year actuarial complication-free rates were 91% in the 60-Gy arm and 83% in the 54-Gy arm (not significant), respectively. There was no significant association between the total dose and local control rate and late complications. The outcome of 54 Gy/ 9 fractions was similar to that of 60 Gy/ 10 fractions in patients with early tongue cancer. PMID:22843365

  5. Design and development of an inflatable latex balloon to reduce rectal and bladder doses for patients undergoing high dose rate brachytherapy

    Directory of Open Access Journals (Sweden)

    Raghukumar P

    2009-01-01

    Full Text Available Multiple fractions of High Dose Rate (HDR brachytherapy along with external beam therapy is the common method of treatment for cancer of the uterine cervix. Urinary bladder and rectum are the organs at risk (OARs that receive a significant dose during treatment. To reduce the dose to these organs, a majority of hospitals use vaginal gauze packing, as it is a simple, nontraumatic, and easy method. This article describes the design and development of an inflatable balloon that can be used along with the applicator as a substitute for gauze packing. The balloon has two parts-the bladder part (B-part and the rectum part (R-part, both of them are independently inflatable. The selection of the material, its width, length, and thickness are described. A mould/former for making the balloon was designed. Polished steel was used as the mould. This was dipped in specially prepared natural rubber latex (NRL solution several times; the layers were dried and stripped to get the balloon. The composition of NRL and the compounding recipe of the latex are also described. Physical tests like tensile strength, elongation at break, bursting volume, and radiation attenuation caused by the balloon, were checked. Biological tests for assessing type I and type IV allergies, like dermal irritation and skin irritation tests, were also done.

  6. Clinical application of a OneDose(TM) MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Kinhikar, Rajesh A [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Sharma, Pramod K [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Tambe, Chandrashekhar M [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Mahantshetty, Umesh M [Department of Radiation Oncology, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Sarin, Rajiv [Advanced Centre for Training Research and Education in Cancer, Kharghar, Navi Mumbai (India); Deshpande, Deepak D [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Shrivastava, Shyam K [Department of Radiation Oncology, Tata Memorial Hospital, Parel, Mumbai 400 012 (India)

    2006-07-21

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose(TM) in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs. (note)

  7. Possible use of EPDM in radioactive waste disposal: Long term low dose rate and short term high dose rate irradiation in aquatic and atmospheric environment

    Science.gov (United States)

    Hacıoğlu, Fırat; Özdemir, Tonguç; Çavdar, Seda; Usanmaz, Ali

    2013-02-01

    In this study, changes in the properties of ethylene propylene diene terpolymer (EPDM) irradiated with different dose rates in ambient atmosphere and aqueous environment were investigated. Irradiations were carried out both with low dose and high dose rate irradiation sources. EPDM samples which were differentiated from each other by peroxide type and 5-ethylidene 2-norbornene (ENB) contents were used. Long term low dose rate irradiations were carried out for the duration of up to 2.5 years (total dose of 1178 kGy) in two different irradiation environments. Dose rates (both high and low), irradiation environments (in aquatic and open to atmosphere), and peroxide types (aliphatic or aromatic) were the parameters studied. Characterization of irradiated EPDM samples were performed by hardness, compression, tensile, dynamic mechanical analysis (DMA), TGA-FTIR, ATR-FTIR, XRD and SEM tests. It was observed that the irradiation in water environment led to a lower degree of degradation when compared to that of irradiation open to atmosphere for the same irradiation dose. In addition, irradiation environment, peroxide type and dose rate had effects on the extent of change in the properties of EPDM. It was observed that EPDM is relatively radiation resistant and a candidate polymer for usage in radioactive waste management.

  8. Early effects comparison of X-rays delivered at high-dose-rate pulses by a plasma focus device and at low dose rate on human tumour cells.

    Science.gov (United States)

    Virelli, A; Zironi, I; Pasi, F; Ceccolini, E; Nano, R; Facoetti, A; Gavoçi, E; Fiore, M R; Rocchi, F; Mostacci, D; Cucchi, G; Castellani, G; Sumini, M; Orecchia, R

    2015-09-01

    A comparative study has been performed on the effects of high-dose-rate (DR) X-ray beams produced by a plasma focus device (PFMA-3), to exploit its potential medical applications (e.g. radiotherapy), and low-DR X-ray beams produced by a conventional source (XRT). Experiments have been performed at 0.5 and 2 Gy doses on a human glioblastoma cell line (T98G). Cell proliferation rate and potassium outward currents (IK) have been investigated by time lapse imaging and patch clamp recordings. The results showed that PFMA-3 irradiation has a greater capability to reduce the proliferation rate activity with respect to XRT, while it does not affect IK of T98G cells at any of the dose levels tested. XRT irradiation significantly reduces the mean IK amplitude of T98G cells only at 0.5 Gy. This work confirms that the DR, and therefore the source of radiation, is crucial for the planning and optimisation of radiotherapy applications.

  9. 3-D conformal treatment of prostate cancer to 74 Gy vs. high-dose-rate brachytherapy boost: A cross-sectional quality-of-life survey

    Energy Technology Data Exchange (ETDEWEB)

    Vordermark, Dirk [Univ. of Wuerzburg (DE). Dept. of Radiation Oncology] (and others)

    2006-09-15

    The effects of two modalities of dose-escalated radiotherapy on health-related quality of life (HRQOL) were compared. Forty-one consecutive patients were treated with a 3-D conformal (3-DC) boost to 74 Gy, and 43 with high-dose rate (HDR) brachytherapy boost (2x9 Gy), following 3-D conformal treatment to 46 Gy. Median age was 70 years in both groups, median initial PSA was 7.9 {mu}g/l in 3-DC boost patients and 8.1 {mu}g/l in HDR boost patients. Stage was 7 in 52% and 47%, respectively. HRQOL was assessed cross-sectionally using EORTC QLQ-C30 and organ-specific PR25 modules 3-32 (median 19) and 4-25 (median 14) months after treatment, respectively. Questionnaires were completed by 93% and 97% of patients, respectively. Diarrhea and insomnia scores were significantly increased in both groups. In the PR25 module, scores of 3-DC boost and HDR boost patients for urinary, bowel and treatment-related symptoms were similar. Among responders, 34% of 3-DC boost patients and 86% of HDR boost patients had severe erectile problems. Dose escalation in prostate cancer by either 3-DC boost to 74 Gy or HDR brachytherapy boost appears to result in similar HRQOL profiles.

  10. Dosimetry analyses comparing high-dose-rate brachytherapy, administered as monotherapy for localized prostate cancer, with stereotactic body radiation therapy simulated using CyberKnife.

    Science.gov (United States)

    Fukuda, Shoichi; Seo, Yuji; Shiomi, Hiroya; Yamada, Yuji; Ogata, Toshiyuki; Morimoto, Masahiro; Konishi, Koji; Yoshioka, Yasuo; Ogawa, Kazuhiko

    2014-11-01

    The purpose of this study was to perform dosimetry analyses comparing high-dose-rate brachytherapy (HDR-BT) with simulated stereotactic body radiotherapy (SBRT). We selected six consecutive patients treated with HDR-BT monotherapy in 2010, and a CyberKnife SBRT plan was simulated for each patient using computed tomography images and the contouring set used in the HDR-BT plan for the actual treatment, but adding appropriate planning target volume (PTV) margins for SBRT. Then, dosimetric profiles for PTVs of the rectum, bladder and urethra were compared between the two modalities. The SBRT plan was more homogenous and provided lower dose concentration but better coverage for the PTV. The maximum doses in the rectum were higher in the HDR-BT plans. However, the HDR-BT plan provided a sharper dose fall-off around the PTV, resulting in a significant and considerable difference in volume sparing of the rectum with the appropriate PTV margins added for SBRT. While the rectum D5cm(3) for HDR-BT and SBRT was 30.7 and 38.3 Gy (P urethra. These results suggest that SBRT as an alternative to HDR-BT in hypofractionated radiotherapy for prostate cancer might have an advantage for bladder and urethra dose sparing, but for the rectum only when proper PTV margins for SBRT are adopted.

  11. Clinicopathologic Comparison of High-Dose-Rate Endorectal Brachytherapy versus Conventional Chemoradiotherapy in the Neoadjuvant Setting for Resectable Stages II and III Low Rectal Cancer

    Directory of Open Access Journals (Sweden)

    Jessica A. Smith

    2012-01-01

    Full Text Available Purpose. To assess for differences in clinical, radiologic, and pathologic outcomes between patients with stage II-III rectal adenocarcinoma treated neoadjuvantly with conventional external beam radiotherapy (3D conformal radiotherapy (3DRT or intensity-modulated radiotherapy (IMRT versus high-dose-rate endorectal brachytherapy (EBT. Methods. Patients undergoing neoadjuvant EBT received 4 consecutive daily 6.5 Gy fractions without chemotherapy, while those undergoing 3DRT or IMRT received 28 daily 1.8 Gy fractions with concurrent 5-fluorouracil. Data was collected prospectively for 7 EBT patients and retrospectively for 25 historical 3DRT/IMRT controls. Results. Time to surgery was less for EBT compared to 3DRT and IMRT (P<0.001. There was a trend towards higher rate of pathologic CR for EBT (P=0.06. Rates of margin and lymph node positivity at resection were similar for all groups. Acute toxicity was less for EBT compared to 3DRT and IMRT (P=0.025. Overall and progression-free survival were noninferior for EBT. On MRI, EBT achieved similar complete response rate and reduction in tumor volume as 3DRT and IMRT. Histopathologic comparison showed that EBT resulted in more localized treatment effects and fewer serosal adhesions. Conclusions. EBT offers several practical benefits over conventional radiotherapy techniques and appears to be at least as effective against low rectal cancer as measured by short-term outcomes.

  12. Current status of afterloading in gynecological contact therapy

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, M.; Fournier, D. von; Schulz-Wendtland, R.; Kuttig, H.; Junkermann, H.

    1987-01-12

    The present state of the remote-controlled afterloading technique is described. Beside the description of the development and the advantages of this method we discuss the currently available afterloading equipment as well as the appropriate radionuclids. The simulation of the treatment of the classic schools from Paris, Stockholm and Manchester is demonstrated by means of proper application combinations. Finally advantages and disadvantages of the HDR and LDR-treatment - especially in regard to radio-biological effects - are discussed.

  13. High-dose-rate interstitial brachytherapy in combination with androgen deprivation therapy for prostate cancer. Are high-risk patients good candidates

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Ken; Narumi, Yoshifumi [Osaka Medical College, Department of Radiology, Takatsuki, Osaka (Japan); Yamazaki, Hideya; Masui, Koji [Kyoto Prefectural University of Medicine, Department of Radiology, Kyoto (Japan); Takenaka, Tadashi [National Hospital Organization Osaka National Hospital, Department of Radiology, Osaka city, Osaka (Japan); Kotsuma, Tadayuki; Yoshida, Mineo; Tanaka, Eiichi [National Hospital Organization Osaka National Hospital, Department of Radiation Oncology, Osaka city, Osaka (Japan); Yoshioka, Yasuo [Osaka University Graduate School of Medicine, Department of Radiation Oncology, Suita, Osaka (Japan); Oka, Toshitsugu [National Hospital Organization Osaka National Hospital, Department of Urology, Osaka city, Osaka (Japan)

    2014-11-15

    To evaluate the effectiveness of high-dose-rate interstitial brachytherapy (HDR-ISBT) as the only form of radiotherapy for high-risk prostate cancer patients. Between July 2003 and June 2008, we retrospectively evaluated the outcomes of 48 high-risk patients who had undergone HDR-ISBT at the National Hospital Organization Osaka National Hospital. Risk group classification was according to the criteria described in the National Comprehensive Cancer Network (NCCN) guidelines. Median follow-up was 73 months (range 12-109 months). Neoadjuvant androgen deprivation therapy (ADT) was administered to all 48 patients; 12 patients also received adjuvant ADT. Maximal androgen blockade was performed in 37 patients. Median total treatment duration was 8 months (range 3-45 months). The planned prescribed dose was 54 Gy in 9 fractions over 5 days for the first 13 patients and 49 Gy in 7 fractions over 4 days for 34 patients. Only one patient who was over 80 years old received 38 Gy in 4 fractions over 3 days. The clinical target volume (CTV) was calculated for the prostate gland and the medial side of the seminal vesicles. A 10-mm cranial margin was added to the CTV to create the planning target volume (PTV). The 5-year overall survival and biochemical control rates were 98 and 87 %, respectively. Grade 3 late genitourinary and gastrointestinal complications occurred in 2 patients (4 %) and 1 patient (2 %), respectively; grade 2 late genitourinary and gastrointestinal complications occurred in 5 patients (10 %) and 1 patient (2 %), respectively. Even for high-risk patients, HDR-ISBT as the only form of radiotherapy combined with ADT achieved promising biochemical control results, with acceptable late genitourinary and gastrointestinal complication rates. (orig.) [German] Beurteilung der Wirksamkeit von interstitieller Brachytherapie mit Hochdosisraten (''high-dose-rate interstitial brachytherapy'', HDR-ISBT) als einzige Form der Radiotherapie fuer Hochrisiko

  14. High-dose-rate-intracavitary brachytherapy applications and the difference in the bladder and rectum doses: A study from rural centre of Maharashatra, India

    Directory of Open Access Journals (Sweden)

    Jain Vandana

    2007-01-01

    Full Text Available Aim : To report the difference in the bladder and rectum doses with different applications by the radiotherapists in the same patient of the carcinoma of the uterine cervix treated by multiple fractions of high-dose-rate (HDR intracavitary brachytherapy (ICBT. Materials and Methods : Between January 2003 to December 2004, a total of 60 cases of the carcinoma uterine cervix were selected randomly for the retrospective analyses. All 60 cases were grouped in six groups according to the treating radiotherapist who did the HDR-ICBT application. Three radiotherapists were considered for this study, named A, B and C. Ten cases for each radiotherapist in whom all three applications were done by the same radiotherapist. And 10 cases for each radiotherapist with shared applications in the same patient (A+B, A+C and B+C. The bladder and rectal doses were calculated in reference to point "A" dose and were limited to 80% of prescribed point "A" dose, as per ICRU-38 recommendations. Received dose grouped in three groups- less then 80% (< 80%, 80-100% and above 100% (>100%. A total of 180 applications for 60 patients were calculated for the above analyses. Results : There is a lot of difference in the bladder and rectal doses with the application by the different radiotherapists, even in the same patient with multiple fractions of HDR-ICBT. Applications by ′A′ radiotherapist were within the limits in the self as well as in the shared groups more number of times, by ′B′ radiotherapist was more times exceeding the limit and by ′C′ radiotherapist doses were in between the A and B. Discussion and Conclusion : For the rectal and bladder doses most important factors are patient′s age, disease stage, duration between EBRT and HDR-ICRT and patient anatomy, but these differences can be minimized to some extent by careful application, proper packing and proper fixation.

  15. Cosmetic Analysis Following Breast-Conserving Surgery and Adjuvant High-Dose-Rate Interstitial Brachytherapy for Early-Stage Breast Cancer: A Prospective Clinical Study

    Energy Technology Data Exchange (ETDEWEB)

    Garsa, Adam A.; Ferraro, Daniel J.; DeWees, Todd [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Margenthaler, Julie A. [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Naughton, Michael [Department of Medicine, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Aft, Rebecca [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Department of Surgery, John Cochran Veterans Hospital, St. Louis, Missouri (United States); Gillanders, William E.; Eberlein, Timothy [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Matesa, Melissa A. [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Zoberi, Imran, E-mail: izoberi@radonc.wustl.edu [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States)

    2013-03-15

    Purpose: To prospectively evaluate cosmetic outcomes in women treated with accelerated partial breast irradiation using high-dose-rate interstitial brachytherapy for early-stage breast cancer. Methods and Materials: Between 2004 and 2008, 151 patients with early-stage breast cancer were enrolled in a phase 2 prospective clinical trial. Eligible patients had stage Tis-T2 tumors of ≤3 cm that were excised with negative margins and with no nodal involvement. Patients received 3.4 Gy twice daily to a total dose of 34 Gy. Both the patients and the treating radiation oncologist qualitatively rated cosmesis as excellent, good, fair, or poor over time and ascribed a cause for changes in cosmesis. Cosmetic outcome was evaluated quantitatively by percentage of breast retraction assessment (pBRA). Patients also reported their satisfaction with treatment over time. Results: Median follow-up was 55 months. The rates of excellent-to-good cosmesis reported by patients and the treating radiation oncologist were 92% and 97% pretreatment, 91% and 97% at 3 to 4 months' follow-up, 87% and 94% at 2 years, and 92% and 94% at 3 years, respectively. Breast infection and adjuvant chemotherapy were independent predictors of a fair-to-poor cosmetic outcome at 3 years. Compared to pretreatment pBRA (7.35), there was no significant change in pBRA over time. The volume receiving more than 150 Gy (V150) was the only significant predictor of pBRA. The majority of patients (86.6%) were completely satisfied with their treatment. Conclusions: Patients and the treating physician reported a high rate of excellent-to-good cosmetic outcomes at all follow-up time points. Acute breast infection and chemotherapy were associated with worse cosmetic outcomes. Multicatheter interstitial brachytherapy does not significantly change breast size as measured by pBRA.

  16. Application of a pelvic phantom in brachytherapy dosimetry for high-dose-rate (HDR) 192Ir source based on Monte Carlo simulations

    Science.gov (United States)

    Ahn, Woo Sang; Choi, Wonsik; Shin, Seong Soo; Jung, Jinhong

    2014-08-01

    In this study, we evaluate how the radial dose function is influenced by the source position as well as the phantom size and shape. A pelvic water phantom similar to the pelvic shape of a human body was designed by averaging dimensions obtained from computed tomography (CT) images of patients treated with brachytherapy for cervical cancer. Furthermore, for the study of the effects of source position on the dose distribution, the position of the source in the water phantom was determined by using the center of mass of the gross target volume (GTV) in the CT images. To obtain the dosimetric parameter of a high-dose-rate (HDR) 192Ir source, we performed Monte Carlo simulations by using the Monte Carlo n-particle extended code (MCNPX). The radial dose functions obtained using the pelvic water phantom were compared with those of spherical phantom with different sizes, including the Monte Carlo (MC) results of Williamson and Li. Differences between the radial dose functions from this study and the data in the literature increased with the radial distances. The largest differences appeared for spherical phantom with the smallest size. In contrast to the published MC results, the radial dose function of the pelvic water phantom significantly decreased with radial distance in the vertical direction because full scattering was not possible. When the source was located in posterior position 2 cm from the center in the pelvic water phantom, the differences between the radial dose functions rapidly decreased with the radial distance in the lower vertical direction. If the International Commission on Radiation Units and Measurements bladder and rectum points are considered, doses to these reference points could be underestimated by up to 1%-2% at a distance of 3 to 6 cm. Our simulation results provide a valid clinical reference data and can used to improve the accuracy of the doses delivered during brachytherapy applied to patients with cervical cancer.

  17. High dose rate vaginal brachytherapy in endometrial cancer after surgery; Curietherapie postoperatoire du fond vaginal de haut debit de dose dans le cancer endometrial

    Energy Technology Data Exchange (ETDEWEB)

    Moreau-Claeys, M.V.; Brunaud, C.; Hoffstetter, S.; Buchheit, I.; Peiffert, D. [Departement de curietherapie, centre Alexis-Vautrin, avenue de Bourgogne, 54511 Vandoeuvre-les-Nancy (France)

    2011-06-15

    Purpose. - This study aimed at analyzing the evolution and type of recurrence in patients treated for stage I endometrial carcinomas, in order to define the respective roles of adjuvant radiotherapy and brachytherapy. Patients and methods. - This mono-centric retrospective study was conducted at Centre Alexis-Vautrin, Nancy, France, between January 1995 and December 2000 on all the patients surgically treated for an endometrial cancer, and then treated with high dose rate vaginal brachytherapy. The brachytherapy was delivered in two or three fractions of 7 Gy at 5 mm from the applicator. Results. - In the good prognosis group, the specific and overall survivals at 5 years were respectively 96.5 and 94.2% with no local recurrence demonstrated. In the intermediate prognostic group, the specific and overall survivals at 5 years were respectively 88 and 85%, with six locoregional recurrences observed among those who did not undergo lymphadenectomy; the overall survival at 5 years was significantly decreased in the absence of external radiation. In the group of poor prognosis (stages II and III), the specific survival at 5 years was respectively 72.8 and 67 %, and the overall survival at 5 years 66.7 and 56.4%. Conclusion. - Results for local control and survival as well as for tolerance were good. So we have decided to deliver high rate brachytherapy for all intermediate or poor prognosis patients and we have abandoned pelvic radiotherapy for good prognosis tumours (stages IA: no myometrium invasion with grade 3 and >50% of myometrium invasion with grades 1 and 2), whatever the lymph nodes surgery they had. We now propose pelvic radiotherapy only for intermediate prognosis tumours (such as IA > 50% of myometrium invasion with grade 3 and IB stages), if patients did not have any lymphatic surgery, or for bad prognosis tumours. (authors)

  18. Value of diffusion weighted MR imaging as an early surrogate parameter for evaluation of tumor response to high-dose-rate brachytherapy of colorectal liver metastases

    Directory of Open Access Journals (Sweden)

    Röhl Friedrich-Wilhelm

    2011-04-01

    Full Text Available Abstract Background To assess the value of diffusion weighted imaging (DWI as an early surrogate parameter for treatment response of colorectal liver metastases to image-guided single-fraction 192Ir-high-dose-rate brachytherapy (HDR-BT. Methods Thirty patients with a total of 43 metastases underwent CT- or MRI-guided HDR-BT. In 13 of these patients a total of 15 additional lesions were identified, which were not treated at the initial session and served for comparison. Magnetic resonance imaging (MRI including breathhold echoplanar DWI sequences was performed prior to therapy (baseline MRI, 2 days after HDR-BT (early MRI as well as after 3 months (follow-up MRI. Tumor volume (TV and intratumoral apparent diffusion coefficient (ADC were measured independently by two radiologists. Statistical analysis was performed using univariate comparison, ANOVA and paired t test as well as Pearson's correlation. Results At early MRI no changes of TV and ADC were found for non-treated colorectal liver metastases. In contrast, mean TV of liver lesions treated with HDR-BT increased by 8.8% (p = 0.054 while mean tumor ADC decreased significantly by 11.4% (p p = 0.027 without significant change of mean ADC values. In contrast, mean TV of treated lesions decreased by 47.0% (p = 0.026 while the mean ADC increased inversely by 28.6% compared to baseline values (p Conclusions DWI is a promising imaging biomarker for early prediction of tumor response in patients with colorectal liver metastases treated with HDR-BT, yet the optimal interval between therapy and early follow-up needs to be elucidated.

  19. High-dose-rate interstitial brachytherapy in head and neck cancer: do we need a look back into a forgotten art - a single institute experience.

    Science.gov (United States)

    Bhalavat, Rajendra; Chandra, Manish; Pareek, Vibhay; Nellore, Lalitha; George, Karishma; Nandakumar, P; Bauskar, Pratibha

    2017-04-01

    To evaluate the treatment outcomes with high-dose-rate (HDR) interstitial brachytherapy (HDR-BRT) in head and neck cancers (HNC). Fifty-eight patients with HNC as per American Joint Committee on Cancer (AJCC) TNM staging criteria were analyzed retrospectively between 2008 and 2015. Forty-two patients received external beam radiotherapy (EBRT) with HDR-BRT and 16 patients received BRT alone. The survival was calculated with respect to median biological equivalent doses (BED) and median 2 Gy equivalent dose (EQD2), keeping α/β = 10 for tumor. Loco-regional control and disease free survival was assessed. The median follow-up period was 25 months (2-84 months). The disease-free survival (DFS) probability at year 1 was 82.7%, and 68% at year 7. The overall survival probability was 91.3% at year 1 and 85.8% at year 7. The local control rate was 70%. The rate of recurrence was 30%. Distant metastasis rate was 17.2%. The median BED and EQD2, respectively, were 86.78 Gy and 71.6 Gy. The DFS was 74.1% and 75.9% in patients receiving a dose more than median BED and EQD2, respectively, and was 64.8% and 61.5% for less than the median dose. The overall outcome was good with implementation of HDR-BRT used alone or as boost, and shows DFS as better when the dose received is more than the median BED and median EQD2. The role of HDR-BRT in HNC is a proven, effective, and safe treatment method with excellent long term outcome as seen in this study, which reflects the need for reviving the forgotten art and science of interstitial brachytherapy in HNC.

  20. Dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with high-dose-rate brachytherapy for large prostate volumes

    Energy Technology Data Exchange (ETDEWEB)

    Yang, George; Strom, Tobin J.; Shrinath, Kushagra; Mellon, Eric A.; Fernandez, Daniel C.; Biagioli, Matthew C. [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Wilder, Richard B., E-mail: mcbiagioli@yahoo.com [Cancer Treatment Centers of America, Newnan, GA (United States)

    2015-05-15

    Purpose: to evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes. Materials and methods: one hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL) were treated with high-dose-rate (HDR) brachytherapy ± intensity modulated radiation therapy (IMRT) to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38%) unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE) version 4. Results: median follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3%) patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17%) patients developed Grade 2 acute urinary retention. American Urological Association (AUA) symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p-0.04). There was no ≥ Grade 3 acute toxicity. Conclusions: dosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes. (author)

  1. Time-driven activity-based costing of low-dose-rate and high-dose-rate brachytherapy for low-risk prostate cancer.

    Science.gov (United States)

    Ilg, Annette M; Laviana, Aaron A; Kamrava, Mitchell; Veruttipong, Darlene; Steinberg, Michael; Park, Sang-June; Burke, Michael A; Niedzwiecki, Douglas; Kupelian, Patrick A; Saigal, Christopher

    Cost estimates through traditional hospital accounting systems are often arbitrary and ambiguous. We used time-driven activity-based costing (TDABC) to determine the true cost of low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy for prostate cancer and demonstrate opportunities for cost containment at an academic referral center. We implemented TDABC for patients treated with I-125, preplanned LDR and computed tomography based HDR brachytherapy with two implants from initial consultation through 12-month followup. We constructed detailed process maps for provision of both HDR and LDR. Personnel, space, equipment, and material costs of each step were identified and used to derive capacity cost rates, defined as price per minute. Each capacity cost rate was then multiplied by the relevant process time and products were summed to determine total cost of care. The calculated cost to deliver HDR was greater than LDR by $2,668.86 ($9,538 vs. $6,869). The first and second HDR treatment day cost $3,999.67 and $3,955.67, whereas LDR was delivered on one treatment day and cost $3,887.55. The greatest overall cost driver for both LDR and HDR was personnel at 65.6% ($4,506.82) and 67.0% ($6,387.27) of the total cost. After personnel costs, disposable materials contributed the second most for LDR ($1,920.66, 28.0%) and for HDR ($2,295.94, 24.0%). With TDABC, the true costs to deliver LDR and HDR from the health system perspective were derived. Analysis by physicians and hospital administrators regarding the cost of care afforded redesign opportunities including delivering HDR as one implant. Our work underscores the need to assess clinical outcomes to understand the true difference in value between these modalities. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  2. Study of the effect of high dose rate on tissue equivalent proportional counter microdosimetric measurements in mixed photon and neutron fields

    Science.gov (United States)

    Aslam; Qashua, N.; Waker, A. J.

    2011-10-01

    This study describes the measurement of lineal energy spectra carried out with a 5.1 cm (2 in.) diameter spherical tissue equivalent proportional counter (TEPC) simulating 2 μm tissue equivalent (TE) site diameter in low energy mixed photon-neutron fields with varying dose rates generated by employing the McMaster University 1.25 MV double stage Tandetron accelerator. The 7Li (p, n) 7Be reaction was employed to generate a variety of mixed fields of photons and low energy neutrons using proton beam energy ranging 1.89-2.56 MeV. The dose rate at a given beam energy was varied by changing the beam current. Dose rates that resulted in dead times as high as 75% were employed to study the effect of dose rate on quality, microdosimetric averages ( y¯F and y¯D), absorbed dose and dose equivalent. We have observed that high dose rates due to both photons and neutrons in a mixed field of radiation result in pile up of pulses and distort the lineal energy spectrum measured under these conditions. The pile up effect and hence the distortion in the lineal energy spectrum becomes prominent with dose rates, which result in dead times larger than 25% for the high linear energy transfer (LET) radiation component. Intense neutron fields, which may amount to 75% dead time, could result in a 50% or even larger increase in the values of the microsdosimetric averages and the neutron quality factor. This study demonstrates moderate dose rates that do not result in dead times of more than 20-25% due to either of the component radiation or due to both components of mixed field radiation generate results that are acceptable for radiation monitoring.

  3. CT computer-optimized high-dose-rate brachytherapy with surface applicator technique for scar boost radiation after breast reconstruction surgery.

    Science.gov (United States)

    Stewart, Alexandra J; O'Farrell, Desmond A; Bellon, Jennifer R; Hansen, Jorgen L; Duggan, Catherine; Czerminska, Maria A; Cormack, Robert A; Devlin, Phillip M

    2005-01-01

    Immediate breast reconstruction has become increasingly prevalent after mastectomy for breast cancer. Postoperative scar boost radiation for the reconstructed breast presents many planning challenges due to the shape, size, and curvature of the scar. High-dose-rate (HDR) surface applicator brachytherapy is a novel and effective method of delivering scar boost radiation. Two cases, one with a saline implant and one with a transverse rectus abdominis musculocutaneous flap reconstruction, illustrate the method and advantages of HDR optimization of surface applicators. For 2 patients a mold of the breast was made with Aquaplast sheets. A reproducible system was used for arm positioning. Skin fiducials, including tattoos from external beam planning, were matched to fiducials on the mold. HDR catheters were sited on the mold at 1cm intervals, with the central catheter situated along the scar. Topographically, both scars demonstrated extreme curvature in both craniocaudal and mediolateral directions. A CT computer-optimized HDR plan was developed, with the reference dose prescribed at the skin surface. The dosimetry was compared to single-field and matched-field electron plans. This surface applicator technique provided a uniform skin dose of 100% to the entire clinical target volume (CTV) without hot spots in both patients. The patient position and surface applicator setup were consistently reproducible. The patients tolerated the treatment well with minimal skin erythema. In the single-field electron plan, skin dose was decreased to 50% at the periphery of the scar. Matching fields addressed this depth dose decrement, but resulted in large localized hot spots of more than 200% centrally in each field. CT computer-optimized HDR surface applicator brachytherapy provided a reproducible homogeneous method of treating highly curved scars on the reconstructed breast. Electron beam treatment would result in longer and more complex treatments yet still provide a less

  4. A comparison of anatomy-based inverse planning with simulated annealing and graphical optimization for high-dose-rate prostate brachytherapy.

    Science.gov (United States)

    Morton, Gerard C; Sankreacha, Raxa; Halina, Patrick; Loblaw, Andrew

    2008-01-01

    Dose distribution in a high-dose-rate (HDR) brachytherapy implant is optimized by adjusting source dwell positions and dwell times along the implanted catheters. Inverse planning with fast simulated annealing (IPSA) is a recently developed algorithm for anatomy-based inverse planning, capable of generating an optimized plan in less than 1min. The purpose of this study is to compare dose distributions achieved using IPSA to those obtained with a graphical optimization (GrO) algorithm for prostate HDR brachytherapy. This is a retrospective study of 63 consecutive prostate HDR brachytherapy implants planned and treated using on-screen GrO to a dose of 10Gy per implant. All plans were then recalculated using IPSA, without changing any parameters (contours, catheters, number, or location of dwell positions). The IPSA and GrO plans were compared with respect to target coverage, conformality, dose homogeneity, and normal tissue dose. The mean volume of target treated to 100% of prescription dose (V(100)) was 97.1% and 96.7%, and mean Conformal Index 0.71 and 0.68 with GrO and IPSA, respectively. IPSA plans had a higher mean homogeneity index (0.69 vs. 0.63, p<0.001) and lower volume of target receiving 150% (30.2% vs. 35.6%, p<0.001) and 200% (10.7% vs. 12.7%, p<0.001) of the prescription dose. Mean dose to urethra, rectum, and bladder were all significantly lower with IPSA (p<0.001). IPSA plans tended to be more reproducible, with smaller standard deviations for all measured parameters. Plans generated using IPSA provide similar target coverage to those obtained using GrO but with lower dose to normal structures and greater dose homogeneity.

  5. Results of concomitant chemoradiation for cervical cancer using high dose rate intracavitary brachytherapy: Study of JROSG (Japan Radiation Oncology Study Group)

    Energy Technology Data Exchange (ETDEWEB)

    Sakata, Koh-Ichi (Dept. of Radiology, Sapporo Medical Univ., School of Medicine, Sapporo (JP)); Sakurai, Hideyuki; Suzuki, Yoshiyuki (Dept. of Radiology and Radiation Oncology, Gunna Univ., School of Medicine, Gunna (JP)) (and others)

    2008-03-15

    The purpose of this study was to clarify outcome for concurrent chemoradiation (CT-RT) in locally advanced cervix cancer in Japan. This is a non-randomized retrospective analysis of 226 patients treated with definitive CT-RT or radiotherapy alone (RT alone) in nine institutions between 2001 and 2003. External irradiation consisted of whole pelvic irradiation and pelvic side wall boost irradiation, using a central shield during the latter half of the treatment with the anteroposterior parallel opposing technique. The external beam irradiation was performed with 1.8 or 2 Gy per fraction. High-dose-rate intracavitary brachytherapy (HDR) was performed in all cases. In chemotherapy, platinum based drugs were used alone or in combination with other drugs such as 5FU. Grade of late complications was scaled retrospectively with CTCv2.0. Overall survival rate at 50 months of stage Ib, II and III, IV was 82% and 66% in CR-RT and 81% and 43% in R alone, respectively. Disease-free survival rate at 50 months of stage Ib, II and III, IV was 74% and 59% in CR-RT and 76% and 52% in R alone, respectively. There was no significant difference between CT-RT and RT for overall survival and disease free survival. Univariate analysis suggested that loco-regional control was better with CT-RT, but multivariate analysis could not confirm this finding. Compared to RT alone, CT-RT caused significantly more acute and late complications. Thus, late complication (grade 3-4) free survival rate at 50 month was 69% for CT-RT and 86% for RT alone (p<0.01). The therapeutic window with concomitant radiochemotherapy and HDR brachytherapy may be narrow, necessitating a close control of dose volume parameters and adherence to systems for dose prescription

  6. High-dose-rate Intracavitary Radiotherapy in the Management of Cervical Intraepithelial Neoplasia 3 and Carcinoma In Situ Presenting With Poor Histologic Factors After Undergoing Excisional Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Bae, E-mail: ybkim3@yuhs.ac [Department of Radiation Oncology, Severance Hospital, Yonsei University, College of Medicine, Seoul (Korea, Republic of); Kim, Young Tae [Department of Obstetrics and Gynecology, Severance Hospital, Yonsei University, College of Medicine, Seoul (Korea, Republic of); Cho, Nam Hoon [Department of Pathology, Severance Hospital, Yonsei University, College of Medicine, Seoul (Korea, Republic of); Koom, Woong Sub [Department of Radiation Oncology, Severance Hospital, Yonsei University, College of Medicine, Seoul (Korea, Republic of); Kim, Sunghoon; Kim, Sang Wun; Nam, Eun Ji [Department of Obstetrics and Gynecology, Severance Hospital, Yonsei University, College of Medicine, Seoul (Korea, Republic of); Kim, Gwi Eon [Department of Radiation Oncology, Severance Hospital, Yonsei University, College of Medicine, Seoul (Korea, Republic of)

    2012-09-01

    Purpose: To assess the effectiveness of high-dose-rate intracavitary radiotherapy (HDR-ICR) in patients with cervical intraepithelial neoplasia 3 (CIN 3) and carcinoma in situ (CIS) presenting with poor histologic factors for predicting residual disease after undergoing diagnostic excisional procedures. Methods and Materials: This study was a retrospective analysis of 166 patients with CIN 3 (n=15) and CIS (n=151) between October 1986 and December 2005. They were diagnosed by conization (n=158) and punch biopsy (n=8). Pathologic analysis showed 135 cases of endocervical gland involvement (81.4%), 74 cases of positive resection margins (44.5%), and 52 cases of malignant cells on endocervical curettage (31.3%). All patients were treated with HDR-ICR using Co{sup 60} or Ir{sup 192} at a cancer center. The dose was prescribed at point A located 2 cm superior to the external os and 2 cm lateral to the axis of the tandem for intact uterus. Results: Median age was 61 years (range, 29-77). The median total dose of HDR-ICR was 30 Gy/6 fractions (range, 30-52). At follow-up (median, 152 months), 2 patients developed recurrent diseases: 1 CIN 2 and 1 invasive carcinoma. One hundred and forty patients survived and 26 patients died, owing to nonmalignant intercurrent disease. Rectal bleeding occurred in one patient; however, this symptom subsided with conservative management. Conclusions: Our data showed HDR-ICR is an effective modality for CIN 3 and CIS patients presenting with poor histologic factors after excisional procedures. HDR-ICR should be considered as a definitive treatment in CIN 3 and CIS patients with possible residual disease after undergoing excisional procedures.

  7. Optimization of deterministic transport parameters for the calculation of the dose distribution around a high dose-rate 192Ir brachytherapy source.

    Science.gov (United States)

    Gifford, Kent A; Price, Michael J; Horton, John L; Wareing, Todd A; Mourtada, Firas

    2008-06-01

    The goal of this work was to calculate the dose distribution around a high dose-rate 192Ir brachytherapy source using a multi-group discrete ordinates code and then to compare the results with a Monte Carlo calculated dose distribution. The unstructured tetrahedral mesh discrete ordinates code Attila version 6.1.1 was used to calculate the photon kerma rate distribution in water around the Nucletron microSelectron mHDRv2 source. MCNPX 2.5.c was used to compute the Monte Carlo water photon kerma rate distribution. Two hundred million histories were simulated, resulting in standard errors of the mean of less than 3% overall. The number of energy groups, S(n) (angular order), P(n) (scattering order), and mesh elements were varied in addition to the method of analytic ray tracing to assess their effects on the deterministic solution. Water photon kerma rate matrices were exported from both codes into an in-house data analysis software. This software quantified the percent dose difference distribution, the number of points within +/- 3% and +/- 5%, and the mean percent difference between the two codes. The data demonstrated that a 5 energy-group cross-section set calculated results to within 0.5% of a 15 group cross-section set. S12 was sufficient to resolve the solution in angle. P2 expansion of the scattering cross-section was necessary to compute accurate distributions. A computational mesh with 55 064 tetrahedral elements in a 30 cm diameter phantom resolved the solution spatially. An efficiency factor of 110 with the above parameters was realized in comparison to MC methods. The Attila code provided an accurate and efficient solution of the Boltzmann transport equation for the mHDRv2 source.

  8. Dosimetric Coverage of the Prostate, Normal Tissue Sparing, and Acute Toxicity with High-Dose-Rate Brachytherapy for Large Prostate Volumes

    Directory of Open Access Journals (Sweden)

    George Yang

    2015-06-01

    Full Text Available ABSTRACTPurposeTo evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes.Materials and MethodsOne hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL were treated with high-dose-rate (HDR brachytherapy ± intensity modulated radiation therapy (IMRT to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38% unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE version 4.ResultsMedian follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3% patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17% patients developed Grade 2 acute urinary retention. American Urological Association (AUA symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p=0.04. There was no ≥ Grade 3 acute toxicity.ConclusionsDosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes.

  9. The impact of body mass index on rectal dose in locally advanced cervical cancer treated with high-dose-rate brachytherapy.

    Science.gov (United States)

    Lim, Jihoon; Durbin-Johnson, Blythe; Valicenti, Richard; Mathai, Matthew; Stern, Robin L; Mayadev, Jyoti

    2013-01-01

    The impact of body mass index (BMI) on rectal dose in brachytherapy for cervical cancer is unknown. We assessed the association of BMI on rectal dose and lower gastrointestinal (GI) toxicity. Between 2007 and 2010, 51 patients with 97 brachytherapy planning images were reviewed. Volumetric measurements of the maximum percentage, mean percentage, dose to 2cc (D2cc), and dose to 1cc (D1cc) of the rectum, and the Internal Commission on Radiation Units and Measurement (ICRU) rectal point were recorded. Linear mixed effect models, analysis of variance, and regression analyses were used to determine the correlation between multiple observations or to detect a difference in the mean. The GI acute and late toxicity were prospectively recorded and retrospectively analyzed. The average BMI (kg/m(2)) was 27.7 with a range of 17.4-46.6. Among the patients, 8% were morbidly obese, 25% obese, 25% overweight, 40% normal weight, and 2% underweight. The mean D1cc, D2cc, mean rectal dose (%), maximum rectal dose (%), and ICRU rectum was 3.03 Gy, 2.78 Gy, 20%, 60%, and 2.99 Gy, respectively. On multivariate analysis, there was a significant decrease in the D1cc and D2cc rectal dose (p=0.016), ICRU rectal point dose (p=0.022), and mean rectal dose percentage (p=0.021) with an increase in BMI. There was, however, no statistically significant relationship between BMI and GI toxicity. Obesity decreases the rectal dose given in high-dose-rate brachytherapy for locally advanced cervical cancer because of an increase in fatty tissue in the recto-uterine space. There is no significant correlation between BMI and acute or late GI toxicity. Published by Elsevier Inc.

  10. Dosimetric feasibility of ablative dose escalated focal monotherapy with MRI-guided high-dose-rate (HDR) brachytherapy for prostate cancer.

    Science.gov (United States)

    Hosni, Ali; Carlone, Marco; Rink, Alexandra; Ménard, Cynthia; Chung, Peter; Berlin, Alejandro

    2017-01-01

    To determine the dosimetric feasibility of dose-escalated MRI-guided high-dose-rate brachytherapy (HDR-BT) focal monotherapy for prostate cancer (PCa). In all patients, GTV was defined with mpMRI, and deformably registered onto post-catheter insertion planning MRI. PTV included the GTV plus 9mm craniocaudal and 5mm in every other direction. In discovery-cohort, plans were obtained for each PTV independently aiming to deliver ⩾16.5Gy/fraction (two fraction schedule) while respecting predefined organs-at-risk (OAR) constraints or halted when achieved equivalent single-dose plan (24Gy). Dosimetric results of original and focal HDR-BT plans were evaluated to develop a planning protocol for the validation-cohort. In discovery-cohort (20-patients, 32-GTVs): PTV D95% ⩾16.5Gy could not be reached in a single plan (3%) and was accomplished (range 16.5-23.8Gy) in 15 GTVs (47%). Single-dose schedule was feasible in 16 (50%) plans. In the validation-cohort (10-patients, 10-GTVs, two separate implants each): plans met acceptable and ideal criteria in 100% and 43-100% respectively. Migration to single-dose treatment schedule was feasible in 7 implants (35%), without relaxing OAR's constraints or increasing the dose (D100% and D35%) to mpMRI-normal prostate (p>0.05). Focal ablative dose-escalated radiation is feasible with the proposed protocol. Prospective studies are warranted to determine the clinical outcomes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Determination of Prognostic Factors for Vaginal Mucosal Toxicity Associated With Intravaginal High-Dose Rate Brachytherapy in Patients With Endometrial Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bahng, Agnes Y.; Dagan, Avner [Department of Radiation Oncology, University of Pennsylvania School of Medicine, Philadelphia, PA (United States); Bruner, Deborah W. [University of Pennsylvania School of Nursing, Philadelphia, PA (United States); Lin, Lilie L., E-mail: lin@xrt.upenn.edu [Department of Radiation Oncology, University of Pennsylvania School of Medicine, Philadelphia, PA (United States)

    2012-02-01

    Purpose: The objective of this study was to determine the patient- and treatment-related prognostic factors associated with vaginal toxicity in patients who received intravaginal high dose rate (HDR) brachytherapy alone as adjuvant treatment for endometrial cancer. Secondary goals of this study included a quantitative assessment of optimal dilator use frequency and a crude assessment of clinical predictors for compliant dilator use. Methods and Materials: We retrospectively reviewed the charts of 100 patients with histologically confirmed endometrial cancer who underwent total hysterectomy and bilateral salpingo-oophorectomy with or without lymph node dissection and adjuvant intravaginal brachytherapy between 1995 and 2009 at the Hospital of University of Pennsylvania. The most common treatment regimen used was 21 Gy in three fractions (71 patients). Symptoms of vaginal mucosal toxicity were taken from the history and physical exams noted in the patients' charts and were graded according to the Common Toxicity Criteria for Adverse Events v. 4.02. Results: The incidence of Grade 1 or asymptomatic vaginal toxicity was 33% and Grade 2-3 or symptomatic vaginal toxicity was 14%. Multivariate analysis of age, active length, and dilator use two to three times a week revealed odds ratios of 0.93 (p = 0.013), 3.96 (p = 0.008), and 0.17 (p = 0.032) respectively. Conclusion: Increasing age, vaginal dilator use of at least two to three times a week, and shorter active length were found to be significantly associated with a decreased risk of vaginal stenosis. Future prospective studies are necessary to validate our findings.

  12. Outcomes of salvage high-dose-rate brachytherapy with or without external beam radiotherapy for isolated vaginal recurrence of endometrial cancer

    Directory of Open Access Journals (Sweden)

    Shuhei Sekii

    2017-05-01

    Full Text Available Purpose: This study was designed to retrospectively analyze outcomes of high-dose-rate (HDR brachytherapy, with or without external beam radiotherapy (EBRT, in patients with vaginal recurrence of endometrial carcinoma, and to identify factors prognostic of patient outcomes. Material and methods : The medical records of all patients who underwent HDR brachytherapy for initial recurrence in the vagina of endometrial cancer after definitive surgery between 1992 and 2014 were retrospectively reviewed. All patients underwent either intracavitary brachytherapy (ICBT or interstitial brachytherapy (ISBT with or without EBRT. Late toxicity was graded using the EORTC (LENT/SOMA scale, revised in 1995. Results : Thirty-seven patients were identified. The median follow-up time was 48 months (range: 6-225 months. Of these 37 patients, 23 underwent ICBT, 14 underwent ISBT, and 26 underwent EBRT. Tumor size at first examination of initial relapse was significantly larger in the ISBT than in the ICBT group. The 4-year respective overall survival (OS, local control (LC, and progression-free survival (PFS rates in the entire cohort were 81.0%, 77.9%, and 56.8%, respectively. The interval between diagnosis of first recurrence and radiotherapy (< 3 months, ≥ 3 months was a significant predictor of LC and PFS. OS and LC rates did not differ significantly in the ICBT and ISBT groups. Two patients experienced grade 2 rectal bleeding, and four experienced grade 2 hematuria. No grade 3 or higher late complications were observed. Conclusions : Salvage HDR brachytherapy is an optimal for treating vaginal recurrence of endometrial carcinoma with acceptable morbidity. Early radiotherapy, including brachytherapy, should be considered for women who experience vaginal recurrence of endometrial cancer.

  13. Determination of prognostic factors for vaginal mucosal toxicity associated with intravaginal high-dose rate brachytherapy in patients with endometrial cancer.

    Science.gov (United States)

    Bahng, Agnes Y; Dagan, Avner; Bruner, Deborah W; Lin, Lilie L

    2012-02-01

    The objective of this study was to determine the patient- and treatment-related prognostic factors associated with vaginal toxicity in patients who received intravaginal high dose rate (HDR) brachytherapy alone as adjuvant treatment for endometrial cancer. Secondary goals of this study included a quantitative assessment of optimal dilator use frequency and a crude assessment of clinical predictors for compliant dilator use. We retrospectively reviewed the charts of 100 patients with histologically confirmed endometrial cancer who underwent total hysterectomy and bilateral salpingo-oophorectomy with or without lymph node dissection and adjuvant intravaginal brachytherapy between 1995 and 2009 at the Hospital of the University of Pennsylvania. The most common treatment regimen used was 21 Gy in three fractions (71 patients). Symptoms of vaginal mucosal toxicity were taken from the history and physical exams noted in the patients' charts and were graded according to the Common Toxicity Criteria for Adverse Events v. 4.02. The incidence of Grade 1 or asymptomatic vaginal toxicity was 33% and Grade 2-3 or symptomatic vaginal toxicity was 14%. Multivariate analysis of age, active length, and dilator use two to three times a week revealed odds ratios of 0.93 (p = 0.013), 3.96 (p = 0.008), and 0.17 (p = 0.032) respectively. Increasing age, vaginal dilator use of at least two to three times a week, and shorter active length were found to be significantly associated with a decreased risk of vaginal stenosis. Future prospective studies are necessary to validate our findings. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Shielding effect of a customized intraoral mold including lead material in high-dose-rate 192-Ir brachytherapy for oral cavity cancer.

    Science.gov (United States)

    Kudoh, Takaharu; Ikushima, Hitoshi; Honda, Eiichi

    2012-01-01

    A high-dose-rate (HDR) 192-Ir brachytherapy using a customized intraoral mold is effective for superficial oral cavity cancer, and the surrounding normal tissue is kept away from the radioactive source with gauze pads and/or mouth piece for reducing the dose on the normal tissues. In the Tokushima university hospital, the mold has a lead shield which utilizes the space prepared with sufficient border-molding by a specific dental technique using modeling compound. In HDR 192-Ir brachytherapy using a lead shielded customized intraoral mold, there are no reports measuring the absorbed dose. The purpose of the present study is to measure the absorbed dose and discuss the optimum thickness of lead in HDR 192-Ir brachytherapy using a customized intraoral mold with lead shield using a 1 cm thickness mimic mold. The thickness of lead in the mold could be changed by varying the arrangement of 0.1 cm thickness sheet of the acrylic resin plate and lead. The measured doses at the lateral surface of the mold with thermo-luminescence dosimeter were reduced to 1.12, 0.79, 0.57, 0.41, 0.31, 0.24 and 0.19 Gy and the ratios to the prescription dose were reduced to 56, 40, 29, 21, 16, 12 and 10 percent as lead thickness increased from 0 to 0.6 cm in 0.1 cm increments, respectively. A 0.3 cm thickness lead was considered to be required for a 1 cm thickness mold, and it was necessary to thicken the lead as much as possible with the constraint of limited space in the oral cavity, especially at the fornix vestibule.

  15. A Prospective Longitudinal Clinical Trial Evaluating Quality of Life After Breast-Conserving Surgery and High-Dose-Rate Interstitial Brachytherapy for Early-Stage Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Garsa, Adam A.; Ferraro, Daniel J.; DeWees, Todd A. [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Deshields, Teresa L. [Department of Medicine, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Margenthaler, Julie A.; Cyr, Amy E. [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Naughton, Michael [Department of Medicine, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Aft, Rebecca [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Department of Surgery, John Cochran Veterans Hospital, St. Louis, Missouri (United States); Gillanders, William E.; Eberlein, Timothy [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Matesa, Melissa A.; Ochoa, Laura L. [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Zoberi, Imran, E-mail: izoberi@radonc.wustl.edu [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States)

    2013-12-01

    Purpose: To prospectively examine quality of life (QOL) of patients with early stage breast cancer treated with accelerated partial breast irradiation (APBI) using high-dose-rate (HDR) interstitial brachytherapy. Methods and Materials: Between March 2004 and December 2008, 151 patients with early stage breast cancer were enrolled in a phase 2 prospective clinical trial. Eligible patients included those with Tis-T2 tumors measuring ≤3 cm excised with negative surgical margins and with no nodal involvement. Patients received 3.4 Gy twice daily to a total dose of 34 Gy. QOL was measured using European Organization for Research and Treatment of Cancer (EORTC) QLQ-C30, version 3.0, and QLQ-BR23 questionnaires. The QLQ-C30 and QLQ-BR23 questionnaires were evaluated during pretreatment and then at 6 to 8 weeks, 3 to 4 months, 6 to 8 months, and 1 and 2 years after treatment. Results: The median follow-up was 55 months. Breast symptom scores remained stable in the months after treatment, and they significantly improved 6 to 8 months after treatment. Scores for emotional functioning, social functioning, and future perspective showed significant improvement 2 years after treatment. Symptomatic fat necrosis was associated with several changes in QOL, including increased pain, breast symptoms, systemic treatment side effects, dyspnea, and fatigue, as well as decreased role functioning, emotional functioning, and social functioning. Conclusions: HDR multicatheter interstitial brachytherapy was well tolerated, with no significant detrimental effect on measured QOL scales/items through 2 years of follow-up. Compared to pretreatment scores, there was improvement in breast symptoms, emotional functioning, social functioning, and future perspective 2 years after treatment.

  16. Posttraumatic Stress Disorder After High-Dose-Rate Brachytherapy for Cervical Cancer With 2 Fractions in 1 Application Under Spinal/Epidural Anesthesia: Incidence and Risk Factors

    Energy Technology Data Exchange (ETDEWEB)

    Kirchheiner, Kathrin, E-mail: kathrin.kirchheiner@meduniwien.ac.at [Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/General Hospital of Vienna, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna (Austria); Czajka-Pepl, Agnieszka [Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/General Hospital of Vienna, Vienna (Austria); Ponocny-Seliger, Elisabeth [Department of Psychology, Sigmund Freud Private University Vienna, Vienna (Austria); Scharbert, Gisela; Wetzel, Léonore [Department of Anaesthesia, General Intensive Care and Pain Management, Medical University of Vienna/General Hospital of Vienna, Vienna (Austria); Nout, Remi A. [Department of Clinical Oncology, Leiden University Medical Center, Leiden (Netherlands); Sturdza, Alina [Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/General Hospital of Vienna, Vienna (Austria); Dimopoulos, Johannes C. [Metropolitan Hospital, Athens (Greece); Dörr, Wolfgang; Pötter, Richard [Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/General Hospital of Vienna, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna (Austria)

    2014-06-01

    Purpose: To investigate the psychological consequences of high-dose-rate brachytherapy with 2 fractions in 1 application under spinal/epidural anesthesia in the treatment of locally advanced cervical cancer. Methods and Materials: In 50 patients with locally advanced cervical cancer, validated questionnaires were used for prospective assessment of acute and posttraumatic stress disorder (ASD/PTSD) (Impact of Event Scale–Revision), anxiety/depression (Hospital Anxiety and Depression Scale), quality of life (European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core 30/Cervical Cancer 24), physical functioning (World Health Organization performance status), and pain (visual analogue scale), before and during treatment and 1 week and 3 months after treatment. Qualitative interviews were recorded in open format for content analysis. Results: Symptoms of ASD occurred in 30% of patients 1 week after treatment; and of PTSD in 41% 3 months after treatment in association with this specific brachytherapy procedure. Pretreatment predictive variables explain 82% of the variance of PTSD symptoms. Helpful experiences were the support of the treatment team, psychological support, and a positive attitude. Stressful factors were pain, organizational problems during treatment, and immobility between brachytherapy fractions. Conclusions: The specific brachytherapy procedure, as performed in the investigated mono-institutional setting with 2 fractions in 1 application under spinal/epidural anesthesia, bears a considerable risk of traumatization. The source of stress seems to be not the brachytherapy application itself but the maintenance of the applicator under epidural anesthesia in the time between fractions. Patients at risk may be identified before treatment, to offer targeted psycho-social support. The patients' open reports regarding helpful experiences are an encouraging feedback for the treatment team; the reported stressful

  17. Clinical outcome in patients with prostate cancer treated with external beam radiotherapy and high dose-rate iridium 192 brachytherapy boost: A 6-year follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Kaelkner, Karl Mikael; Wahlgren, Thomas; Ryberg, Marianne; Cohn-Cedermark, G abriella; Castellanos, Enrique; Nilsson, Sten [Dept. of Oncology-Pathology, Radi umhemmet, Karolinska Univ. Hospital and Inst., Stockholm (Sweden); Zimmerman, Rolf [Dept. of Oncology-Pathology, Soedersjukhuset, Karolinska Univ. Hospital and Inst., Stockh olm (Sweden); Nilsson, Josef; Lundell, Marie [Dept. of Medical Physics, Karolinska Univ. Hospital and Inst., Stockholm (Sweden); Fowler, Jack [Dept. of Human Oncology , Univ. of Wisconsin Medical School, Madison (United States); Levitt, Seymour [Dept. of Therapeutic R adiology, Univ. of Minnesota, Minneapolis, MN (United States); Hellstroem, Magnus [Dept. o f Urology, Karolinska Univ. Hospital and Inst., Stockholm (Sweden)

    2007-10-15

    To report the long-term results for treatment of localized carcinoma of the prostate using high dose rate (HDR) brachytherapy, conformal external beam radiotherapy (3D EBRT) and neo-adjuvant hormonal therapy (TAB). From 1998 through 1999, 154 patients with localized prostate cancer were entered in the trial. Biologically no evidence of disease (bNED) was defined at PSA levels < 2 {mu}g/l. In order to compare the results of this treatment with other treatment modalities, the patient's pre-treatment data were used to calculate the estimated 5-year PSA relapse free survival using Kattan's nomograms for radical prostatectomy (RP) and 3D EBRT. After 6 years of follow-up, 129 patients remain alive. The actual 5-year relapse-free survival is 84%. None of the patients demonstrated clinical signs of local recurrence. The median PSA at follow-up among the relapse-free patients was 0.05 {mu}g/l. Among the 80 patients who presented with clinical stage T3 tumours, 55 (68%) were relapse-free. The expected 5-year relapse-free survival using nomograms for RP and 3D EBRT was 54% and 70%, respectively. Late rectal toxicity RTOG grade 3 occurred in 1% of the patients. Late urinary tract toxicity RTOG grade 3 developed in 4% of the patients. Combined treatment, utilizing HDR, 3D EBRT and TAB, produces good clinical results. Rectal toxicity is acceptable. Urinary tract toxicity, most likely can be explained by the fact that during the first years of this treatment, no effort was made to localize the urethra, which was assumed to be in the middle of the prostate.

  18. Updated results of high-dose rate brachytherapy and external beam radiotherapy for locally and locally advanced prostate cancer using the RTOG-ASTRO phoenix definition

    Directory of Open Access Journals (Sweden)

    Antonio C. Pellizzon

    2008-06-01

    Full Text Available PURPOSE: To evaluate the prognostic factors for patients with local or locally advanced prostate cancer treated with external beam radiotherapy (RT and high dose rate brachytherapy (HDR according to the RTOG-ASTRO Phoenix Consensus Conference. MATERIALS AND METHODS: The charts of 209 patients treated between 1997 and 2005 with localized RT and HDR as a boost at the Department of Radiation Oncology, AC Camargo Hospital, Sao Paulo, Brazil were reviewed. Clinical and treatment parameters i.e.: patient's age, Gleason score, clinical stage, initial PSA (iPSA, risk group (RG for biochemical failure, doses of RT and HDR were evaluated. Median age and median follow-up time were 68 and 5.3 years, respectively. Median RT and HDR doses were 45 Gy and 20 Gy. RESULTS: Disease specific survival (DSS at 3.3 year was 94.2%. Regarding RG, for the LR (low risk, IR (intermediate risk and HR (high risk, the DSS rates at 3.3 years were 91.5%, 90.2% and 88.5%, respectively. On univariate analysis prognostic factors related to DSS were RG (p = 0.040, Gleason score ≤ 6 ng/mL (p = 0.002, total dose of HDR ≥ 20 Gy (p < 0.001 On multivariate analysis the only statistical significant predictive factor for biochemical control (bNED was the RG, p < 0.001 (CI - 1.147-3.561. CONCLUSIONS: Although the radiation dose administered to the prostate is an important factor related to bNED, this could not be established with statistical significance in this group of patients. To date , in our own experience, HDR associated to RT could be considered a successful approach in the treatment of prostate cancer.

  19. Technique of after-loading interstitial implants.

    Science.gov (United States)

    Syed, A M; Feder, B H

    1977-01-01

    Interstitial implants are either removable or permanent (and occasionally a combination of both). Permanent implants are generally utilized where tumors are not accessible enough to permit easy removal of sources or where accurate source distribution is less critical. They are useful for cancers of the lung, pancreas, prostate, bladder, lymph nodes, etc. Radon and gold-198 have been largely replaced by iodine-125. Our major interests are in the removable after-loading iridium-192 implant techniques. Template (steel guide) and non-template (plastic tube) techniques are utilized. Templates are preferred where the tumor volume can only be approached from one side and where accurate positioning of sources would otherwise be difficult. They are useful for cancers of the cervix, vagina, urethra, and rectum. Non-template (plastic tube) techniques are preferred where the tumor volume can be approached from at least two sides and where templates are either not feasible or not essential for accurate positioning of sources. The single needle non-template approach is useful for cancers of lip, nodes, and breast (plastic button) and for cancers of the oral cavity and oropharynx (gold button). The paired needle non-template approach is useful for cancers of the gum, retromolar trigone, and base of tongue (loop technique) and for cancers of the palate (arch technique). Procedures for each technique are described in detail.

  20. Evaluation of a real-time BeO ceramic fiber-coupled luminescence dosimetry system for dose verification of high dose rate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Alexandre M. Caraça, E-mail: alexandre.santos@adelaide.edu.au [Department of Medical Physics, Royal Adelaide Hospital, Adelaide 5000, Australia and Institute for Photonics and Advanced Sensing, School of Physical Sciences, University of Adelaide, Adelaide 5005 (Australia); Mohammadi, Mohammad [Department of Medical Physics, Royal Adelaide Hospital, Adelaide 5000, Australia and Department of Medical Physics, Faculty of Medicine, Hamadan University of Medical Sciences, Hamadan 65167-3-8736 (Iran, Islamic Republic of); Shahraam, Afshar V. [Laser Physics and Photonic Devices Laboratories, School of Engineering, The University of South Australia, Adelaide 5095 (Australia); Institute for Photonics and Advanced Sensing, School of Physical Sciences, University of Adelaide, Adelaide 5005 (Australia)

    2015-11-15

    Purpose: The authors evaluate the capability of a beryllium oxide (BeO) ceramic fiber-coupled luminescence dosimeter, named radioluminescence/optically stimulated luminescence (RL/OSL) BeO FOD, for dosimetric verification of high dose rate (HDR) treatments. The RL/OSL BeO FOD is capable of RL and OSL measurements. Methods: The RL/OSL BeO FOD is able to be inserted in 6F proguide needles, used in interstitial HDR treatments. Using a custom built Perspex phantom, 6F proguide needles could be submerged in a water tank at 1 cm separations from each other. A second background fiber was required to correct for the stem effect. The stem effect, dose linearity, reproducibility, depth-dose curves, and angular and temperature dependency of the RL/OSL BeO FOD were characterised using an Ir-192 source. The RL/OSL BeO FOD was also applied to the commissioning of a 10 mm horizontal Leipzig applicator. Results: Both the RL and OSL were found to be reproducible and their percentage depth-dose curves to be in good agreement with those predicted via TG-43. A combined uncertainty of 7.9% and 10.1% (k = 1) was estimated for the RL and OSL, respectively. For the 10 mm horizontal Leipzig applicator, measured percentage depth doses were within 5% agreement of the published reference calculations. The output at the 3 mm prescription depth for a 1 Gy delivery was verified to be 0.99 ± 0.08 Gy and 1.01 ± 0.10 Gy by the RL and OSL, respectively. Conclusions: The use of the second background fiber under the current setup means that the two fibers cannot fit into a single 6F needle. Hence, use of the RL is currently not adequate for the purpose of in vivo brachytherapy dosimetry. While not real-time, the OSL is shown to be adequate for in vivo brachytherapy dosimetry.

  1. High-Dose-Rate Brachytherapy as Monotherapy Delivered in Two Fractions Within One Day for Favorable/Intermediate-Risk Prostate Cancer: Preliminary Toxicity Data

    Energy Technology Data Exchange (ETDEWEB)

    Ghilezan, Michel, E-mail: mghilezan@beaumont.edu [Department of Radiation Oncology, William Beaumont Hospital and Rose Cancer Institute, Royal Oak, Michigan (United States); Martinez, Alvaro; Gustason, Gary; Krauss, Daniel; Antonucci, J. Vito; Chen, Peter; Fontanesi, James; Wallace, Michelle; Ye Hong; Casey, Alyse; Sebastian, Evelyn; Kim, Leonard; Limbacher, Amy [Department of Radiation Oncology, William Beaumont Hospital and Rose Cancer Institute, Royal Oak, Michigan (United States)

    2012-07-01

    Purpose: To report the toxicity profile of high-dose-rate (HDR)-brachytherapy (BT) as monotherapy in a Human Investigation Committee-approved study consisting of a single implant and two fractions (12 Gy Multiplication-Sign 2) for a total dose of 24 Gy, delivered within 1 day. The dose was subsequently increased to 27 Gy (13.5 Gy Multiplication-Sign 2) delivered in 1 day. We report the acute and early chronic genitourinary and gastrointestinal toxicity. Methods and Materials: A total of 173 patients were treated between December 2005 and July 2010. However, only the first 100 were part of the IRB-approved study and out of these, only 94 had a minimal follow-up of 6 months, representing the study population for this preliminary report. All patients had clinical Stage T2b or less (American Joint Committee on Cancer, 5th edition), Gleason score 6-7 (3+4), and prostate-specific antigen level of {<=}12 ng/mL. Ultrasound-guided HDR-BT with real-time dosimetry was used. The prescription dose was 24 Gy for the first 50 patients and 27 Gy thereafter. The dosimetric goals and constraints were the same for the two dose groups. Toxicity was scored using the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. The highest toxicity scores encountered at any point during follow-up are reported. Results: The median follow-up was 17 months (range, 6-40.5). Most patients had Grade 0-1 acute toxicity. The Grade 2 acute genitourinary toxicity was mainly frequency/urgency (13%), dysuria (5%), hematuria, and dribbling/hesitancy (2%). None of the patients required a Foley catheter at any time; however, 8% of the patients experienced transient Grade 1 diarrhea. No other acute gastrointestinal toxicities were found. The most common chronic toxicity was Grade 2 urinary frequency/urgency in 16% of patients followed by dysuria in 4% of patients; 2 patients had Grade 2 rectal bleeding and 1 had Grade 4, requiring laser treatment. Conclusions: Favorable

  2. Modeling normal tissue complication probability from repetitive computed tomography scans during fractionated high-dose-rate brachytherapy and external beam radiotherapy of the uterine cervix.

    Science.gov (United States)

    Dale, E; Hellebust, T P; Skjønsberg, A; Høgberg, T; Olsen, D R

    2000-07-01

    To calculate the normal tissue complication probability (NTCP) of late radiation effects on the rectum and bladder from repetitive CT scans during fractionated high-dose-rate brachytherapy (HDRB) and external beam radiotherapy (EBRT) of the uterine cervix and compare the NTCP with the clinical frequency of late effects. Fourteen patients with cancer of the uterine cervix (Stage IIb-IVa) underwent 3-6 (mean, 4.9) CT scans in treatment position during their course of HDRB using a ring applicator with an Iridium stepping source. The rectal and bladder walls were delineated on the treatment-planning system, such that a constant wall volume independent of organ filling was achieved. Dose-volume histograms (DVH) of the rectal and bladder walls were acquired. A method of summing multiple DVHs accounting for variable dose per fraction were applied to the DVHs of HDRB and EBRT together with the Lyman-Kutcher NTCP model fitted to clinical dose-volume tolerance data from recent studies. The D(mean) of the DVH from EBRT was close to the D(max) for both the rectum and bladder, confirming that the DVH from EBRT corresponded with homogeneous whole-organ irradiation. The NTCP of the rectum was 19.7% (13.5%, 25. 9%) (mean and 95% confidence interval), whereas the clinical frequency of late rectal sequelae (Grade 3-4, RTOG/EORTC) was 13% based on material from 200 patients. For the bladder the NTCP was 61. 9% (46.8%, 76.9%) as compared to the clinical frequency of Grade 3-4 late effects of 14%. If only 1 CT scan from HDRB was assumed available, the relative uncertainty (standard deviation or SD) of the NTCP value for an arbitrary patient was 20-30%, whereas 4 CT scans provided an uncertainty of 12-13%. The NTCP for the rectum was almost consistent with the clinical frequency of late effects, whereas the NTCP for bladder was too high. To obtain reliable (SD of 12-13%) NTCP values, 3-4 CT scans are needed during 5-7 fractions of HDRB treatments.

  3. Development and implementation of a remote audit tool for high dose rate (HDR) Ir-192 brachytherapy using optically stimulated luminescence dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Casey, Kevin E.; Kry, Stephen F.; Howell, Rebecca M.; Followill, David [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, Texas 77030 (United States); Alvarez, Paola; Lawyer, Ann [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States)

    2013-11-15

    Purpose: The aim of this work was to create a mailable phantom with measurement accuracy suitable for Radiological Physics Center (RPC) audits of high dose-rate (HDR) brachytherapy sources at institutions participating in National Cancer Institute-funded cooperative clinical trials. Optically stimulated luminescence dosimeters (OSLDs) were chosen as the dosimeter to be used with the phantom.Methods: The authors designed and built an 8 × 8 × 10 cm{sup 3} prototype phantom that had two slots capable of holding Al{sub 2}O{sub 3}:C OSLDs (nanoDots; Landauer, Glenwood, IL) and a single channel capable of accepting all {sup 192}Ir HDR brachytherapy sources in current clinical use in the United States. The authors irradiated the phantom with Nucletron and Varian {sup 192}Ir HDR sources in order to determine correction factors for linearity with dose and the combined effects of irradiation energy and phantom characteristics. The phantom was then sent to eight institutions which volunteered to perform trial remote audits.Results: The linearity correction factor was k{sub L}= (−9.43 × 10{sup −5}× dose) + 1.009, where dose is in cGy, which differed from that determined by the RPC for the same batch of dosimeters using {sup 60}Co irradiation. Separate block correction factors were determined for current versions of both Nucletron and Varian {sup 192}Ir HDR sources and these vendor-specific correction factors differed by almost 2.6%. For the Nucletron source, the correction factor was 1.026 [95% confidence interval (CI) = 1.023–1.028], and for the Varian source, it was 1.000 (95% CI = 0.995–1.005). Variations in lateral source positioning up to 0.8 mm and distal/proximal source positioning up to 10 mm had minimal effect on dose measurement accuracy. The overall dose measurement uncertainty of the system was estimated to be 2.4% and 2.5% for the Nucletron and Varian sources, respectively (95% CI). This uncertainty was sufficient to establish a ±5% acceptance

  4. Registering prostate external beam radiotherapy with a boost from high-dose-rate brachytherapy: a comparative evaluation of deformable registration algorithms.

    Science.gov (United States)

    Moulton, Calyn R; House, Michael J; Lye, Victoria; Tang, Colin I; Krawiec, Michele; Joseph, David J; Denham, James W; Ebert, Martin A

    2015-12-14

    Registering CTs for patients receiving external beam radiotherapy (EBRT) with a boost dose from high-dose-rate brachytherapy (HDR) can be challenging due to considerable image discrepancies (e.g. rectal fillings, HDR needles, HDR artefacts and HDR rectal packing materials). This study is the first to comparatively evaluate image processing and registration methods used to register the rectums in EBRT and HDR CTs of prostate cancer patients. The focus is on the rectum due to planned future analysis of rectal dose-volume response. For 64 patients, the EBRT CT was retrospectively registered to the HDR CT with rigid registration and non-rigid registration methods in VelocityAI. Image processing was undertaken on the HDR CT and the rigidly-registered EBRT CT to reduce the impact of discriminating features on alternative non-rigid registration methods applied in the software suite for Deformable Image Registration and Adaptive Radiotherapy Research (DIRART) using the Horn-Schunck optical flow and Demons algorithms. The propagated EBRT-rectum structures were compared with the HDR structure using the Dice similarity coefficient (DSC), Hausdorff distance (HD) and average surface distance (ASD). The image similarity was compared using mutual information (MI) and root mean squared error (MSE). The displacement vector field was assessed via the Jacobian determinant (JAC). The post-registration alignments of rectums for 21 patients were visually assessed. The greatest improvement in the median DSC relative to the rigid registration result was 35 % for the Horn-Schunck algorithm with image processing. This algorithm also provided the best ASD results. The VelocityAI algorithms provided superior HD, MI, MSE and JAC results. The visual assessment indicated that the rigid plus deformable multi-pass method within VelocityAI resulted in the best rectum alignment. The DSC, ASD and HD improved significantly relative to the rigid registration result if image processing was applied prior

  5. Magnetic Resonance Imaging (MRI) Markers for MRI-Guided High-Dose-Rate Brachytherapy: Novel Marker-Flange for Cervical Cancer and Marker Catheters for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Schindel, Joshua; Muruganandham, Manickam [Department of Radiation Oncology, University of Iowa, Iowa City, Iowa (United States); Pigge, F. Christopher [Department of Chemistry, University of Iowa, Iowa City, Iowa (United States); Anderson, James [Department of Radiation Oncology, University of Iowa, Iowa City, Iowa (United States); Kim, Yusung, E-mail: yusung-kim@uiowa.edu [Department of Radiation Oncology, University of Iowa, Iowa City, Iowa (United States)

    2013-06-01

    Purpose: To present a novel marker-flange, addressing source-reconstruction uncertainties due to the artifacts of a titanium intracavitary applicator used for magnetic resonance imaging (MRI)-guided high-dose-rate (HDR) brachytherapy (BT); and to evaluate 7 different MRI marker agents used for interstitial prostate BT and intracavitary gynecologic HDR BT when treatment plans are guided by MRI. Methods and Materials: Seven MRI marker agents were analyzed: saline solution, Conray-60, copper sulfate (CuSO{sub 4}) (1.5 g/L), liquid vitamin E, fish oil, 1% agarose gel (1 g agarose powder per 100 mL distilled water), and a cobalt–chloride complex contrast (C4) (CoCl{sub 2}/glycine = 4:1). A plastic, ring-shaped marker-flange was designed and tested on both titanium and plastic applicators. Three separate phantoms were designed to test the marker-flange, interstitial catheters for prostate BT, and intracavitary catheters for gynecologic HDR BT. T1- and T2-weighted MRI were analyzed for all markers in each phantom and quantified as percentages compared with a 3% agarose gel background. The geometric accuracy of the MR signal for the marker-flange was measured using an MRI-CT fusion. Results: The CuSO{sub 4} and C4 markers on T1-weighted MRI and saline on T2-weighted MRI showed the highest signals. The marker-flange showed hyper-signals of >500% with CuSO{sub 4} and C4 on T1-weighted MRI and of >400% with saline on T2-weighted MRI on titanium applicators. On T1-weighted MRI, the MRI signal inaccuracies of marker-flanges were measured <2 mm, regardless of marker agents, and that of CuSO{sub 4} was 0.42 ± 0.14 mm. Conclusion: The use of interstitial/intracavitary markers for MRI-guided prostate/gynecologic BT was observed to be feasible, providing accurate source pathway reconstruction. The novel marker-flange can produce extremely intense, accurate signals, demonstrating its feasibility for gynecologic HDR BT.

  6. Comparison of 2D and 3D Imaging and Treatment Planning for Postoperative Vaginal Apex High-Dose Rate Brachytherapy for Endometrial Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Russo, James K. [Department of Radiation Oncology, Hollings Cancer Center, Medical University of South Carolina, Charleston, South Carolina (United States); Armeson, Kent E. [Division of Biostatistics and Epidemiology, Hollings Cancer Center, Medical University of South Carolina, Charleston, South Carolina (United States); Richardson, Susan, E-mail: srichardson@radonc.wustl.edu [Department of Radiation Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri (United States)

    2012-05-01

    Purpose: To evaluate bladder and rectal doses using two-dimensional (2D) and 3D treatment planning for vaginal cuff high-dose rate (HDR) in endometrial cancer. Methods and Materials: Ninety-one consecutive patients treated between 2000 and 2007 were evaluated. Seventy-one and 20 patients underwent 2D and 3D planning, respectively. Each patient received six fractions prescribed at 0.5 cm to the superior 3 cm of the vagina. International Commission on Radiation Units and Measurements (ICRU) doses were calculated for 2D patients. Maximum and 2-cc doses were calculated for 3D patients. Organ doses were normalized to prescription dose. Results: Bladder maximum doses were 178% of ICRU doses (p < 0.0001). Two-cubic centimeter doses were no different than ICRU doses (p = 0.22). Two-cubic centimeter doses were 59% of maximum doses (p < 0.0001). Rectal maximum doses were 137% of ICRU doses (p < 0.0001). Two-cubic centimeter doses were 87% of ICRU doses (p < 0.0001). Two-cubic centimeter doses were 64% of maximum doses (p < 0.0001). Using the first 1, 2, 3, 4 or 5 fractions, we predicted the final bladder dose to within 10% for 44%, 59%, 83%, 82%, and 89% of patients by using the ICRU dose, and for 45%, 55%, 80%, 85%, and 85% of patients by using the maximum dose, and for 37%, 68%, 79%, 79%, and 84% of patients by using the 2-cc dose. Using the first 1, 2, 3, 4 or 5 fractions, we predicted the final rectal dose to within 10% for 100%, 100%, 100%, 100%, and 100% of patients by using the ICRU dose, and for 60%, 65%, 70%, 75%, and 75% of patients by using the maximum dose, and for 68%, 95%, 84%, 84%, and 84% of patients by using the 2-cc dose. Conclusions: Doses to organs at risk vary depending on the calculation method. In some cases, final dose accuracy appears to plateau after the third fraction, indicating that simulation and planning may not be necessary in all fractions. A clinically relevant level of accuracy should be determined and further research conducted to address

  7. Comparison of Different Fractionation Schedules Toward a Single Fraction in High-Dose-Rate Brachytherapy as Monotherapy for Low-Risk Prostate Cancer Using 3-Dimensional Radiobiological Models

    Energy Technology Data Exchange (ETDEWEB)

    Mavroidis, Panayiotis, E-mail: mavroidis@uthscsa.edu [Department of Radiation Oncology, University of Texas Health Sciences Center, San Antonio, Texas (United States); Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm (Sweden); Milickovic, Natasa [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach GmbH, Offenbach (Germany); Cruz, Wilbert F. [Department of Radiation Oncology, University of Texas Health Sciences Center, San Antonio, Texas (United States); Tselis, Nikolaos [Strahlenklinik, Klinikum Offenbach GmbH, Offenbach (Germany); Karabis, Andreas [Pi-Medical Ltd., Athens (Greece); Stathakis, Sotirios; Papanikolaou, Nikos [Department of Radiation Oncology, University of Texas Health Sciences Center, San Antonio, Texas (United States); Zamboglou, Nikolaos [Strahlenklinik, Klinikum Offenbach GmbH, Offenbach (Germany); Baltas, Dimos [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach GmbH, Offenbach (Germany); Nuclear and Particle Physics Section, Physics Department, University of Athens, Athens (Greece)

    2014-01-01

    Purpose: The aim of the present study was the investigation of different fractionation schemes to estimate their clinical impact. For this purpose, widely applied radiobiological models and dosimetric measures were used to associate their results with clinical findings. Methods and Materials: The dose distributions of 12 clinical high-dose-rate brachytherapy implants for prostate were evaluated in relation to different fractionation schemes. The fractionation schemes compared were: (1) 1 fraction of 20 Gy; (2) 2 fractions of 14 Gy; (3) 3 fractions of 11 Gy; and (4) 4 fractions of 9.5 Gy. The clinical effectiveness of the different fractionation schemes was estimated through the complication-free tumor control probability (P{sub +}), the biologically effective uniform dose, and the generalized equivalent uniform dose index. Results: For the different fractionation schemes, the tumor control probabilities were 98.5% in 1 × 20 Gy, 98.6% in 2 × 14 Gy, 97.5% in 3 × 11 Gy, and 97.8% in 4 × 9.5 Gy. The corresponding P{sub +} values were 88.8% in 1 × 20 Gy, 83.9% in 2 × 14 Gy, 86.0% in 3 × 11 Gy, and 82.3% in 4 × 9.5 Gy. With use of the fractionation scheme 4 × 9.5 Gy as reference, the isoeffective schemes regarding tumor control for 1, 2, and 3 fractions were 1 × 19.68 Gy, 2 × 13.75 Gy, and 3 × 11.05 Gy. The optimum fractionation schemes for 1, 2, 3, and 4 fractions were 1 × 19.16 Gy with a P{sub +} of 91.8%, 2 × 13.2 Gy with a P{sub +} of 89.6%, 3 × 10.6 Gy with a P{sub +} of 88.4%, and 4 × 9.02 Gy with a P{sub +} of 86.9%. Conclusions: Among the fractionation schemes 1 × 20 Gy, 2 × 14 Gy, 3 × 11 Gy, and 4 × 9.5 Gy, the first scheme was more effective in terms of P{sub +}. After performance of a radiobiological optimization, it was shown that a single fraction of 19.2 to 19.7 Gy (average 19.5 Gy) should produce at least the same benefit as that given by the 4 × 9.5 Gy scheme, and it should reduce the expected total complication probability by

  8. SU-F-19A-09: Propagation of Organ at Risk Contours for High Dose Rate Brachytherapy Planning for Cervical Cancer: A Deformable Image Registration Comparison

    Energy Technology Data Exchange (ETDEWEB)

    Bellon, M; Kumarasiri, A; Kim, J; Shah, M; Elshaikh, M; Chetty, I [Henry Ford Health System, Detroit, MI (United States)

    2014-06-15

    Purpose: To compare the performance of two deformable image registration (DIR) algorithms for contour propagation and to evaluate the accuracy of DIR for use with high dose rate (HDR) brachytherapy planning for cervical cancer. Methods: Five patients undergoing HDR ring and tandem brachytherapy were included in this retrospective study. All patients underwent CT simulation and replanning prior to each fraction (3–5 fractions total). CT-to-CT DIR was performed using two commercially available software platforms: SmartAdapt, Varian Medical Systems (Demons) and Velocity AI, Velocity Medical Solutions (B-spline). Fraction 1 contours were deformed and propagated to each subsequent image set and compared to contours manually drawn by an expert clinician. Dice similarity coefficients (DSC), defined as, DSC(A,B)=2(AandB)/(A+B) were calculated to quantify spatial overlap between manual (A) and deformed (B) contours. Additionally, clinician-assigned visual scores were used to describe and compare the performance of each DIR method and ultimately evaluate which was more clinically acceptable. Scoring was based on a 1–5 scale—with 1 meaning, “clinically acceptable with no contour changes” and 5 meaning, “clinically unacceptable”. Results: Statistically significant differences were not observed between the two DIR algorithms. The average DSC for the bladder, rectum and rectosigmoid were 0.82±0.08, 0.67±0.13 and 0.48±0.18, respectively. The poorest contour agreement was observed for the rectosigmoid due to limited soft tissue contrast and drastic anatomical changes, i.e., organ shape/filling. Two clinicians gave nearly equivalent average scores of 2.75±0.91 for SmartAdapt and 2.75±0.94 for Velocity AI—indicating that for a majority of the cases, more than one of the three contours evaluated required major modifications. Conclusion: Limitations of both DIR algorithms resulted in inaccuracies in contour propagation in the pelvic region, thus hampering the

  9. A non-rigid point matching method with local topology preservation for accurate bladder dose summation in high dose rate cervical brachytherapy.

    Science.gov (United States)

    Chen, Haibin; Zhong, Zichun; Liao, Yuliang; Pompoš, Arnold; Hrycushko, Brian; Albuquerque, Kevin; Zhen, Xin; Zhou, Linghong; Gu, Xuejun

    2016-02-07

    GEC-ESTRO guidelines for high dose rate cervical brachytherapy advocate the reporting of the D2cc (the minimum dose received by the maximally exposed 2cc volume) to organs at risk. Due to large interfractional organ motion, reporting of accurate cumulative D2cc over a multifractional course is a non-trivial task requiring deformable image registration and deformable dose summation. To efficiently and accurately describe the point-to-point correspondence of the bladder wall over all treatment fractions while preserving local topologies, we propose a novel graphic processing unit (GPU)-based non-rigid point matching algorithm. This is achieved by introducing local anatomic information into the iterative update of correspondence matrix computation in the 'thin plate splines-robust point matching' (TPS-RPM) scheme. The performance of the GPU-based TPS-RPM with local topology preservation algorithm (TPS-RPM-LTP) was evaluated using four numerically simulated synthetic bladders having known deformations, a custom-made porcine bladder phantom embedded with twenty one fiducial markers, and 29 fractional computed tomography (CT) images from seven cervical cancer patients. Results show that TPS-RPM-LTP achieved excellent geometric accuracy with landmark residual distance error (RDE) of 0.7  ±  0.3 mm for the numerical synthetic data with different scales of bladder deformation and structure complexity, and 3.7  ±  1.8 mm and 1.6  ±  0.8 mm for the porcine bladder phantom with large and small deformation, respectively. The RDE accuracy of the urethral orifice landmarks in patient bladders was 3.7  ±  2.1 mm. When compared to the original TPS-RPM, the TPS-RPM-LTP improved landmark matching by reducing landmark RDE by 50  ±  19%, 37  ±  11% and 28  ±  11% for the synthetic, porcine phantom and the patient bladders, respectively. This was achieved with a computational time of less than 15 s in all cases

  10. Clinical transition to model-based dose calculation algorithm: A retrospective analysis of high-dose-rate tandem and ring brachytherapy of the cervix.

    Science.gov (United States)

    Jacob, Dayee; Lamberto, Melissa; DeSouza Lawrence, Lana; Mourtada, Firas

    To retrospectively compare clinical dosimetry of CT-based tandem-ring treatment plans using a model-based dose calculation algorithm (MBDCA) with the standard TG-43-based dose formalism. A cohort of 10 cervical cancer cohorts treated using the tandem and ring high-dose-rate applicators were evaluated. The original treatment plans were created using the department CT-based volume optimization clinical standards. All plans originally calculated with TG-43 dose calculation formalism were recalculated using the MBDCA algorithm. The gross target volume and organs at risk (OARs) were contoured on each data set along with significant heterogeneities like air in cavity and high-density plastic tandem and ring components. The patient tissue was modeled as homogenous liquid water. D90, D95, and D100 for gross target volume, D0.1cm(3), D1.0cm(3), and D2.0cm(3) for bladder, rectum, and sigmoid were extracted from dose-volume histograms for TG-43 and MBDCA calculated plans. Mean absolute difference ± 2σ in the above metrics was calculated for each plan. Using the manual applicator contouring method, MBDCA plans (n = 10) showed 2.1 ± 1.1% reduction in dose to Point A average, 2.6 ± 0.9% reduction in Target D90 dose, and 2.1 ± 0.3% dose reduction to OARs. Results from plans using vendor supplied solid applicator models (n = 5) showed 2.2 ± 1.10% reduction in dose to Point A average, 2.7 ± 0.2% reduction in Target D90 dose, and 2.7 ± 1.0% dose reduction on average to OARs. For unshielded plastic gynecologic applicators, minimal dosimetric changes (<5%) were found using MBDCA relative to standard TG-43. Use of solid applicator model is more efficient than manual applicator contouring and also yielded similar MBDCA dosimetric results. Currently, TG-186 dose calculations should be reported along TG-43 until we obtain studies with larger cohorts to fully realize the potential of MBDCA dosimetry. Copyright © 2017 American Brachytherapy Society. Published by

  11. Dose-volume parameters and clinical outcome of CT-guided free-hand high-dose-rate interstitial brachytherapy for cervical cancer

    Science.gov (United States)

    Wang, Yi; Ye, Wei-Jun; Du, Le-Hui; Li, Ai-Ju; Ren, Yu-Feng; Cao, Xin-Ping

    2012-01-01

    Currently, image-based 3-dimentional (3D) planning brachytherapy allows for a better assessment of gross tumor volume (GTV) and the definition and delineation of target volume in cervix cancer. In this study, we investigated the feasibility of our novel computed tomography (CT)-guided free-hand high-dose-rate interstitial brachytherapy (HDRISBT) technique for cervical cancer by evaluating the dosimetry and preliminary clinical outcome of this approach. Dose-volume histogram (DVH) parameters were analyzed according to the Gynecological GEC-ESTRO Working Group recommendations for image-based 3D treatment in cervical cancer. Twenty cervical cancer patients who underwent CT-guided free-hand HDRISBT between March 2009 and June 2010 were studied. With a median of 5 (range, 4–7) implanted needles for each patient, the median dose of brachytherapy alone delivered to 90% of the target volume (D90) was 45 (range, 33–54) Gyα/β10 for high-risk clinical target volume (HR-CTV) and 30 (range, 20–36) Gyα/β10 for intermediate-risk clinical target volume (IR-CTV). The percentage of the CTV covered by the prescribed dose (V100) of HR-CTV with brachytherapy alone was 81.9%–99.2% (median, 96.7%). With an additional dose of external beam radiotherapy (EBRT), the median D90 was 94 (range, 83–104) Gyα/β10 for HR-CTV and 77 (range, 70–87) Gyα/β10 for IR-CTV; the median dose delivered to 100% of the target volume (D100) was 75 (range, 66–84) Gyα/β10 for HR-CTV and 65 (range, 57–73) Gyα/β10 for IR-CTV. The minimum dose to the most irradiated 2 cc volume (D2cc) was 73–96 (median, 83) Gyα/β3 for the bladder, 64–98 (median, 73) Gyα/β3 for the rectum, and 52–69 (median, 61) Gyα/β3 for the sigmoid colon. After a median follow-up of 15 months (range, 3–24 months), two patients experienced local failure, and 1 showed internal iliac nodal metastasis. Despite the relatively small number of needles used, CT-guided HDRISBT for cervical cancer showed favorable

  12. SU-E-T-383: Can Stereotactic Body Radiotherapy Mimic the Dose Distribution of High-Dose-Rate Tandem and Ovoids/ring Brachytherapy?

    Energy Technology Data Exchange (ETDEWEB)

    Park, S; Demanes, J; Kamrava, M [UCLA School of Medicine, Los Angeles, CA (United States); Scanderbeg, D [UCSD Medical Center, La Jolla, CA (United States)

    2014-06-01

    Purpose: To investigate whether stereotactic body radiotherapy (SBRT) using volumetric modulated arc therapy (VMAT) can mimic the dosimetry of tandem and ovoids/ring brachytherapy. Methods: We selected 5 patients treated with 3D-CT based high-dose rate (HDR) brachytherapy using 4 tandem and ovoid and 1 tandem and ring case. Manual optimization based on the Manchester system followed by graphical optimization (Nucletron Oncentra MasterPlan or Varian BrachyVision) was performed to deliver 6.0 Gy per fraction to a high-risk CTV while maintaining dose to organs at risk (OAR) below the ABS recommendations. For theoretical SBRT plans, CT images and OAR contours from the HDR plans were imported into Eclipse (Varian). The SBRT plan was created to mimic the heterogeneity of HDR plans by using a simultaneous integrated boost technique to match the V100, V150, and V200 isodose volumes from HDR. The OAR Dmax from HDR was used to define the OAR dose constraints for SBRT. Target coverage, dose spill-out, and OAR doses (D0.1cc, D1cc, and D2cc) between the HDR and SBRT plans were compared for significance using a two-tail paired ttest. Results: The mean isodose volumes for HDR vs. SBRT were 29.4 cc vs. 29.0 cc (V200, p = 0.674), 49.2 cc vs. 56.3 cc (V150, p = 0.017), 95.4 cc vs. 127.7 cc (V100, p = 0.001), and 271.9 cc vs. 581.6 cc (V50, p = 0.001). The D2cc to OAR for HDR vs. SBRT was 71.6% vs. 96.2% (bladder, p = 0.002), 69.2% vs. 101.7% (rectum, p = 0.0003), and 56.9% vs. 68.6% (sigmoid, p = 0.004). Conclusion: SBRT with VMAT can provide similar dose target coverage (V200), but dose spill-out and doses to OAR were statistically significantly higher than HDR. This study clearly demonstrated that brachytherapy can not be substituted with SBRT in gynecologic cervical cancer treatment.

  13. SU-E-T-579: Impact of Cylinder Size in High-Dose Rate Brachytherapy (HDRBT) for Primary Cancer in the Vagina

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, H; Gopalakrishnan, M; Lee, P; Sathiaseelan, V [Department of Radiation Oncology, Northwestern Memorial Hospital, Chicago, IL (United States)

    2014-06-01

    Purpose: To evaluate the dosimetric impact of cylinder size in high dose rate Brachytherapy for primary vaginal cancers. Methods: Patients treated with HDR vaginal vault radiation in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm increment were analyzed. All patients’ doses were prescribed at the 0.5 cm from the vaginal surface with different treatment lengths. A series of reference points were created to optimize the dose distribution. The fraction dose was 5.5 Gy, the treatment was repeated for 4 times in two weeks. A cylinder volume was contoured in each case according to the prescribed treatment length, and then expanded to 5 mm to get a volume Cylinder-5mm-exp. A volume of PTV-Eval was obtained by subtracting the cylinder volume from the Cylinder-5mm-exp. The shell volume, PTV-Eval serves as the target volume for dosimetric evaluation. Results: DVH curves and average doses of PTV-Eval were obtained. Our results indicated that the DVH curves shifted toward higher dose side when larger cylinder was used instead of smaller ones. When 3.0 cm cylinder was used instead of 2.5 cm, for 3.0 cm treatment length, the average dose only increased 1%, from 790 to 799 cGy. However, the average doses for 3.5 and 4 cm cylinders respectively are 932 and 1137 cGy at the same treatment length. For 5.0 cm treatment length, the average dose is 741 cGy for 2.5 cm cylinder, and 859 cGy for 3 cm cylinder. Conclusion: Our data analysis suggests that for the vaginal intracavitary HDRBT, the average dose is at least 35% larger than the prescribed dose in the studied cases; the size of the cylinder will impact the dose delivered to the target volume. The cylinder with bigger diameter tends to deliver larger average dose to the PTV-Eval.

  14. SU-E-T-620: Dosimetric Compliance Study for a New Prostate Protocol of Combined High Dose Rate Brachytherapy and Stereotactic Body Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Peng, C; Giaddui, T; Den, R; Harrison, A; Yu, Y [Thomas Jefferson University, Philadelphia, PA (United States)

    2014-06-15

    Purpose: To investigate the adherence of treatment plans of prostate cancer patients with the dosimetric compliance criteria of the new in house phase I trial of high dose rate (HDR) brachytherapy combined with stereotactic body radiotherapy (SBRT) for intermediate risk prostate cancer patients. Methods: Ten prostate cancer patients were treated using this trial. They received one fraction of HDR to 15Gy, followed by external beam(EB) boost of 3.2Gy(Level 1, five patients) or 3.94Gy(level 2, five patients) per fraction for 10 or 7 fractions, respectively, both equivalent to EB treatments of 113.5Gy in 2Gy fractions. The EB plans were either IMRT or VMAT plans. DVH analysis was performed to verify the adherence of treatment plans to the dosimetric criteria of the trial. Results: For Level 1 patients, target coverage were adequate, with CTV V32Gy(%) of 99.0±1.0 (mean ± 1 standard deviation), and PTV V31Gy(%) of 99.6±0.3. PTV V32.9Gy(%) is 1.4±3.1 and PTVmax is 32.9±0.2Gy. Rectum, bladder and femoral heads sparing were well within protocol criteria. For Level 2 patients, CTV V27.6Gy(%) is 98.7±1.8; PTV V26.7Gy(%) is 99.0±1.4. PTV V28.4Gy(%) is 1.3±1.4, with three patients having minor deviation from protocol. Again critical structures were spared compliant to the protocol. The analysis of HDR plans show similar results, with adequate dose coverage to the prostate and sparing of critical structures including urethra and rectum. V100(%) and V90(%) of prostate are 96.0±1.1 and 98.9±0.5. Urethra D10(%) is 113.1±2.9. Rectum V80(cc) is 1.4±0.5. Hotspot in prostate is substantially higher than what the protocol specifies. But the criteria for hotspot are only guidelines, serving to lower the dose to urethra . Conclusion: This new high biological equivalent dose prostate trial has been carried out successfully for ten patients. Based on dosimetric analysis, all HDR and external plans were compliant to the protocol criteria, with only minor deviations.

  15. Combined external beam and intraluminal radiotherapy for irresectable Klatskin tumors

    Energy Technology Data Exchange (ETDEWEB)

    Schleicher, U.M. [Klinik fuer Strahlentherapie, Technische Hochschule Aachen (Germany); Staatz, G. [Klinik fuer Radiologische Diagnostik, Technische Hochschule Aachen (Germany); Alzen, G. [Klinik fuer Radiologische Diagnostik, Technische Hochschule Aachen (Germany); Abt. Kinderradiologie, Giessen Univ. (Germany); Andreopoulos, D. [Klinik fuer Strahlentherapie, Technische Hochschule Aachen (Germany); BOC Oncology Centre, Nikosia (Cyprus)

    2002-12-01

    Background: In most cases of proximal cholangiocarcinoma, curative surgery is not possible. Radiotherapy can be used for palliative treatment. We report our experience with combined external beam and intraluminal radiotherapy of advanced Klatskin's tumors. Patients and Methods: 30 patients were treated for extrahepatic proximal bile duct cancer. Our schedule consisted for external beam radiotherapy (median dose 30 Gy) and a high-dose-rate brachytherapy boost (median dose 40 Gy) delivered in four or five fractions, which could be applied completely in twelve of our patients. 15 patients in the brachytherapy and nine patients in the non-brachytherapy group received additional low-dose chemotherapy with 5-fluorouracil. Results: The brachytherapy boost dose improved the effect of external beam radiotherapy by increasing survival from a median of 3.9 months in the non-brachytherapy group to 9.1 months in the brachytherapy group. The effect was obvious in patients receiving a brachytherapy dose above 30 Gy, and in those without jaundice at the beginning of radiotherapy (p<0.05). Conclusions: The poor prognosis in patients with advanced Klatskin's tumors may be improved by combination therapy, with the role of brachytherapy and chemotherapy still to be defined. Our results suggest that patients without jaundice should be offered brachytherapy, and that a full dose of more than 30 Gy should be applied. (orig.) [German] Hintergrund: Bei den meisten Patienten mit proximalen Cholangiokarzinomen ist eine kurative Operation nicht mehr moeglich. Im Rahmen der Palliativbehandlung kann die Strahlentherapie eingesetzt werden. Wir berichten ueber unsere Erfahrungen mit der Kombination aus perkutaner und intraluminaler Strahlentherapie fortgeschrittener Klatskin-Tumoren. Patienten und Methode: 30 Patienten wurden wegen extrahepatischer proximaler Gallengangskarzinome behandelt. Unser Therapieschema umfasste eine perkutane Strahlentherapie (mediane Dosis: 30 Gy) sowie einen

  16. Determination of air kerma standard of high dose rate {sup 192}Ir brachytherapy source; Determinacao da taxa de kerma no ar de referencia para {sup 192}Ir de alta taxa de dose para braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Pires, E.J.; Alves, C.F.E.; Leite, S.P.; Magalhaes, L.A.G.; David, M.G.; Almeida, C.E. de, E-mail: cfealves@gmail.com [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Lab. de Ciencias Radiologicas; Di Prinzio, R. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    This paper presents the methodology developed by the Laboratorio de Ciencias Radiologicas and presently in use for determining of the air kerma standard of {sup 192}Ir high dose rate sources to calibrate well-type chambers. Uncertainty analysis involving the measurements procedure are presented. (author)

  17. The evaluation of a 2D diode array in "magic phantom" for use in high dose rate brachytherapy pretreatment quality assurance.

    Science.gov (United States)

    Espinoza, A; Petasecca, M; Fuduli, I; Howie, A; Bucci, J; Corde, S; Jackson, M; Lerch, M L F; Rosenfeld, A B

    2015-02-01

    High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment deliveries can be challenging due to the high source activity utilized and the need for precise measurements of dwell positions and times. This paper describes the application of a novel phantom, based on a 2D 11 × 11 diode array detection system, named "magic phantom" (MPh), to accurately measure plan dwell positions and times, compare them directly to the treatment plan, determine errors in treatment delivery, and calculate absorbed dose. The magic phantom system was CT scanned and a 20 catheter plan was generated to simulate a nonspecific treatment scenario. This plan was delivered to the MPh and, using a custom developed software suite, the dwell positions and times were measured and compared to the plan. The original plan was also modified, with changes not disclosed to the primary authors, and measured again using the device and software to determine the modifications. A new metric, the "position-time gamma index," was developed to quantify the quality of a treatment delivery when compared to the treatment plan. The MPh was evaluated to determine the minimum measurable dwell time and step size. The incorporation of the TG-43U1 formalism directly into the software allows for dose calculations to be made based on the measured plan. The estimated dose distributions calculated by the software were compared to the treatment plan and to calibrated EBT3 film, using the 2D gamma analysis method. For the original plan, the magic phantom system was capable of measuring all dwell points and dwell times and the majority were found to be within 0.93 mm and 0.25 s, respectively, from the plan. By measuring the altered plan and comparing it to the unmodified treatment plan, the use of the position-time gamma index showed that all modifications made could be readily detected. The MPh was able to

  18. Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: A preliminary performance study

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Jun; Sebastian, Evelyn; Mangona, Victor; Yan Di [Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, Michigan 48073 (United States)

    2013-02-15

    Purpose: In order to increase the accuracy and speed of catheter reconstruction in a high-dose-rate (HDR) prostate implant procedure, an automatic tracking system has been developed using an electromagnetic (EM) device (trakSTAR, Ascension Technology, VT). The performance of the system, including the accuracy and noise level with various tracking parameters and conditions, were investigated. Methods: A direct current (dc) EM transmitter (midrange model) and a sensor with diameter of 1.3 mm (Model 130) were used in the trakSTAR system for tracking catheter position during HDR prostate brachytherapy. Localization accuracy was assessed under both static and dynamic analyses conditions. For the static analysis, a calibration phantom was used to investigate error dependency on operating room (OR) table height (bottom vs midposition vs top), sensor position (distal tip of catheter vs connector end of catheter), direction [left-right (LR) vs anterior-posterior (AP) vs superior-inferior (SI)], sampling frequency (40 vs 80 vs 120 Hz), and interference from OR equipment (present vs absent). The mean and standard deviation of the localization offset in each direction and the corresponding error vectors were calculated. For dynamic analysis, the paths of five straight catheters were tracked to study the effects of directions, sampling frequency, and interference of EM field. Statistical analysis was conducted to compare the results in different configurations. Results: When interference was present in the static analysis, the error vectors were significantly higher at the top table position (3.3 {+-} 1.3 vs 1.8 {+-} 0.9 mm at bottom and 1.7 {+-} 1.0 mm at middle, p < 0.001), at catheter end position (3.1 {+-} 1.1 vs 1.4 {+-} 0.7 mm at the tip position, p < 0.001), and at 40 Hz sampling frequency (2.6 {+-} 1.1 vs 2.4 {+-} 1.5 mm at 80 Hz and 1.8 {+-} 1.1 at 160 Hz, p < 0.001). So did the mean offset errors in the LR direction (-1.7 {+-} 1.4 vs 0.4 {+-} 0.5 mm in AP and 0

  19. Therapeutic analysis of high-dose-rate {sup 192}Ir vaginal cuff brachytherapy for endometrial cancer using a cylindrical target volume model and varied cancer cell distributions

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hualin, E-mail: hualin.zhang@northwestern.edu; Donnelly, Eric D.; Strauss, Jonathan B. [Department of Radiation Oncology, Robert H. Lurie Comprehensive Cancer Center, Northwestern University Feinberg School of Medicine, Northwestern Memorial Hospital, Chicago, Illinois 60611 (United States); Qi, Yujin [Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia)

    2016-01-15

    Purpose: To evaluate high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT) in the treatment of endometrial cancer in a cylindrical target volume with either a varied or a constant cancer cell distributions using the linear quadratic (LQ) model. Methods: A Monte Carlo (MC) technique was used to calculate the 3D dose distribution of HDR VCBT over a variety of cylinder diameters and treatment lengths. A treatment planning system (TPS) was used to make plans for the various cylinder diameters, treatment lengths, and prescriptions using the clinical protocol. The dwell times obtained from the TPS were fed into MC. The LQ model was used to evaluate the therapeutic outcome of two brachytherapy regimens prescribed either at 0.5 cm depth (5.5 Gy × 4 fractions) or at the vaginal mucosal surface (8.8 Gy × 4 fractions) for the treatment of endometrial cancer. An experimentally determined endometrial cancer cell distribution, which showed a varied and resembled a half-Gaussian distribution, was used in radiobiology modeling. The equivalent uniform dose (EUD) to cancer cells was calculated for each treatment scenario. The therapeutic ratio (TR) was defined by comparing VCBT with a uniform dose radiotherapy plan in term of normal cell survival at the same level of cancer cell killing. Calculations of clinical impact were run twice assuming two different types of cancer cell density distributions in the cylindrical target volume: (1) a half-Gaussian or (2) a uniform distribution. Results: EUDs were weakly dependent on cylinder size, treatment length, and the prescription depth, but strongly dependent on the cancer cell distribution. TRs were strongly dependent on the cylinder size, treatment length, types of the cancer cell distributions, and the sensitivity of normal tissue. With a half-Gaussian distribution of cancer cells which populated at the vaginal mucosa the most, the EUDs were between 6.9 Gy × 4 and 7.8 Gy × 4, the TRs were in the range from (5.0){sup 4} to (13

  20. Therapeutic analysis of high-dose-rate (192)Ir vaginal cuff brachytherapy for endometrial cancer using a cylindrical target volume model and varied cancer cell distributions.

    Science.gov (United States)

    Zhang, Hualin; Donnelly, Eric D; Strauss, Jonathan B; Qi, Yujin

    2016-01-01

    To evaluate high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT) in the treatment of endometrial cancer in a cylindrical target volume with either a varied or a constant cancer cell distributions using the linear quadratic (LQ) model. A Monte Carlo (MC) technique was used to calculate the 3D dose distribution of HDR VCBT over a variety of cylinder diameters and treatment lengths. A treatment planning system (TPS) was used to make plans for the various cylinder diameters, treatment lengths, and prescriptions using the clinical protocol. The dwell times obtained from the TPS were fed into MC. The LQ model was used to evaluate the therapeutic outcome of two brachytherapy regimens prescribed either at 0.5 cm depth (5.5 Gy × 4 fractions) or at the vaginal mucosal surface (8.8 Gy × 4 fractions) for the treatment of endometrial cancer. An experimentally determined endometrial cancer cell distribution, which showed a varied and resembled a half-Gaussian distribution, was used in radiobiology modeling. The equivalent uniform dose (EUD) to cancer cells was calculated for each treatment scenario. The therapeutic ratio (TR) was defined by comparing VCBT with a uniform dose radiotherapy plan in term of normal cell survival at the same level of cancer cell killing. Calculations of clinical impact were run twice assuming two different types of cancer cell density distributions in the cylindrical target volume: (1) a half-Gaussian or (2) a uniform distribution. EUDs were weakly dependent on cylinder size, treatment length, and the prescription depth, but strongly dependent on the cancer cell distribution. TRs were strongly dependent on the cylinder size, treatment length, types of the cancer cell distributions, and the sensitivity of normal tissue. With a half-Gaussian distribution of cancer cells which populated at the vaginal mucosa the most, the EUDs were between 6.9 Gy × 4 and 7.8 Gy × 4, the TRs were in the range from (5.0)(4) to (13.4)(4) for the radiosensitive normal

  1. Therapeutic analysis of high-dose-rate 192Ir vaginal cuff brachytherapy for endometrial cancer using a cylindrical target volume model and varied cancer cell distributions

    Science.gov (United States)

    Zhang, Hualin; Donnelly, Eric D.; Strauss, Jonathan B.; Qi, Yujin

    2016-01-01

    Purpose: To evaluate high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT) in the treatment of endometrial cancer in a cylindrical target volume with either a varied or a constant cancer cell distributions using the linear quadratic (LQ) model. Methods: A Monte Carlo (MC) technique was used to calculate the 3D dose distribution of HDR VCBT over a variety of cylinder diameters and treatment lengths. A treatment planning system (TPS) was used to make plans for the various cylinder diameters, treatment lengths, and prescriptions using the clinical protocol. The dwell times obtained from the TPS were fed into MC. The LQ model was used to evaluate the therapeutic outcome of two brachytherapy regimens prescribed either at 0.5 cm depth (5.5 Gy × 4 fractions) or at the vaginal mucosal surface (8.8 Gy × 4 fractions) for the treatment of endometrial cancer. An experimentally determined endometrial cancer cell distribution, which showed a varied and resembled a half-Gaussian distribution, was used in radiobiology modeling. The equivalent uniform dose (EUD) to cancer cells was calculated for each treatment scenario. The therapeutic ratio (TR) was defined by comparing VCBT with a uniform dose radiotherapy plan in term of normal cell survival at the same level of cancer cell killing. Calculations of clinical impact were run twice assuming two different types of cancer cell density distributions in the cylindrical target volume: (1) a half-Gaussian or (2) a uniform distribution. Results: EUDs were weakly dependent on cylinder size, treatment length, and the prescription depth, but strongly dependent on the cancer cell distribution. TRs were strongly dependent on the cylinder size, treatment length, types of the cancer cell distributions, and the sensitivity of normal tissue. With a half-Gaussian distribution of cancer cells which populated at the vaginal mucosa the most, the EUDs were between 6.9 Gy × 4 and 7.8 Gy × 4, the TRs were in the range from (5.0)4 to (13.4)4 for the

  2. The evaluation of a 2D diode array in “magic phantom” for use in high dose rate brachytherapy pretreatment quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Espinoza, A.; Petasecca, M.; Fuduli, I.; Lerch, M. L. F.; Rosenfeld, A. B., E-mail: anatoly@uow.edu.au [Centre for Medical Radiation Physics, University of Wollongong, New South Wales 2522 (Australia); Howie, A.; Bucci, J. [St George Hospital Cancer Care Centre, New South Wales 2217 (Australia); Corde, S.; Jackson, M. [Department of Radiation Oncology, Prince of Wales Hospital, New South Wales 2031 (Australia)

    2015-02-15

    Purpose: High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment deliveries can be challenging due to the high source activity utilized and the need for precise measurements of dwell positions and times. This paper describes the application of a novel phantom, based on a 2D 11 × 11 diode array detection system, named “magic phantom” (MPh), to accurately measure plan dwell positions and times, compare them directly to the treatment plan, determine errors in treatment delivery, and calculate absorbed dose. Methods: The magic phantom system was CT scanned and a 20 catheter plan was generated to simulate a nonspecific treatment scenario. This plan was delivered to the MPh and, using a custom developed software suite, the dwell positions and times were measured and compared to the plan. The original plan was also modified, with changes not disclosed to the primary authors, and measured again using the device and software to determine the modifications. A new metric, the “position–time gamma index,” was developed to quantify the quality of a treatment delivery when compared to the treatment plan. The MPh was evaluated to determine the minimum measurable dwell time and step size. The incorporation of the TG-43U1 formalism directly into the software allows for dose calculations to be made based on the measured plan. The estimated dose distributions calculated by the software were compared to the treatment plan and to calibrated EBT3 film, using the 2D gamma analysis method. Results: For the original plan, the magic phantom system was capable of measuring all dwell points and dwell times and the majority were found to be within 0.93 mm and 0.25 s, respectively, from the plan. By measuring the altered plan and comparing it to the unmodified treatment plan, the use of the position–time gamma index showed that all modifications made could be

  3. A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism.

    Science.gov (United States)

    Ballester, Facundo; Carlsson Tedgren, Åsa; Granero, Domingo; Haworth, Annette; Mourtada, Firas; Fonseca, Gabriel Paiva; Zourari, Kyveli; Papagiannis, Panagiotis; Rivard, Mark J; Siebert, Frank-André; Sloboda, Ron S; Smith, Ryan L; Thomson, Rowan M; Verhaegen, Frank; Vijande, Javier; Ma, Yunzhi; Beaulieu, Luc

    2015-06-01

    In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) (192)Ir source and a virtual water phantom were designed, which can be imported into a TPS. A hypothetical, generic HDR (192)Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic (192)Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra(®) Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS™ ]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201)(3) voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR (192)Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by different investigators. MC results were then

  4. A generic high-dose rate {sup 192}Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

    Energy Technology Data Exchange (ETDEWEB)

    Ballester, Facundo, E-mail: Facundo.Ballester@uv.es [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Carlsson Tedgren, Åsa [Department of Medical and Health Sciences (IMH), Radiation Physics, Faculty of Health Sciences, Linköping University, Linköping SE-581 85, Sweden and Department of Medical Physics, Karolinska University Hospital, Stockholm SE-171 76 (Sweden); Granero, Domingo [Department of Radiation Physics, ERESA, Hospital General Universitario, Valencia E-46014 (Spain); Haworth, Annette [Department of Physical Sciences, Peter MacCallum Cancer Centre and Royal Melbourne Institute of Technology, Melbourne, Victoria 3000 (Australia); Mourtada, Firas [Department of Radiation Oncology, Helen F. Graham Cancer Center, Christiana Care Health System, Newark, Delaware 19713 (United States); Fonseca, Gabriel Paiva [Instituto de Pesquisas Energéticas e Nucleares – IPEN-CNEN/SP, São Paulo 05508-000, Brazil and Department of Radiation Oncology (MAASTRO), GROW, School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Zourari, Kyveli; Papagiannis, Panagiotis [Medical Physics Laboratory, Medical School, University of Athens, 75 MikrasAsias, Athens 115 27 (Greece); Rivard, Mark J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States); Siebert, Frank-André [Clinic of Radiotherapy, University Hospital of Schleswig-Holstein, Campus Kiel, Kiel 24105 (Germany); Sloboda, Ron S. [Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada); and others

    2015-06-15

    Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) {sup 192}Ir source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR {sup 192}Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic {sup 192}Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra{sup ®} Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS{sup TM}]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201){sup 3} voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR {sup 192}Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by

  5. A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate (192) Ir brachytherapy.

    Science.gov (United States)

    Ma, Yunzhi; Vijande, Javier; Ballester, Facundo; Carlsson Tedgren, Åsa; Granero, Domingo; Haworth, Annette; Mourtada, Firas; Fonseca, Gabriel Paiva; Zourari, Kyveli; Papagiannis, Panagiotis; Rivard, Mark J; Siebert, Frank André; Sloboda, Ron S; Smith, Ryan; Chamberland, Marc J P; Thomson, Rowan M; Verhaegen, Frank; Beaulieu, Luc

    2017-07-19

    A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform model-based dose calculation algorithms (MBDCA) dose calculations and comparisons. Its main goal is to facilitate a smooth transition from the AAPM Task Group No. 43 (TG-43) dose calculation formalism, widely being used in clinical practice for brachytherapy, to the one proposed by Task Group No. 186 (TG-186) for MBDCAs. To do so, in this work a hypothetical, generic high-dose rate (HDR) (192) Ir shielded applicator has been designed and benchmarked. A generic HDR (192) Ir shielded applicator was designed based on three commercially available gynecological applicators as well as a virtual cubic water phantom that can be imported into any DICOM-RT compatible treatment planning system (TPS). The absorbed dose distribution around the applicator with the TG-186 (192) Ir source located at one dwell position at its center was computed using two commercial TPSs incorporating MBDCAs (Oncentra(®) Brachy with Advanced Collapsed-cone Engine, ACE(™) , and BrachyVision ACUROS(™) ) and state-of-the-art Monte Carlo (MC) codes, including ALGEBRA, BrachyDose, egs_brachy, Geant4, MCNP6, and Penelope2008. TPS-based volumetric dose distributions for the previously reported "source centered in water" and "source displaced" test cases, and the new "source centered in applicator" test case, were analyzed here using the MCNP6 dose distribution as a reference. Volumetric dose comparisons of TPS results against results for the other MC codes were also performed. Distributions of local and global dose difference ratios are reported. The local dose differences among MC codes are comparable to the statistical uncertainties of the reference datasets for the "source centered in water" and "source

  6. Evaluation of failure modes of computerized planning phase of interstitial implants with high dose rate brachytherapy using HFMEA; Avaliacao dos modos de falha do planejamento computadorizado em implantes intersticiais com braquiterapia de alta taxa de dose usando HFMEA

    Energy Technology Data Exchange (ETDEWEB)

    Biazotto, Bruna; Tokarski, Marcio, E-mail: bruna@ceb.unicamp.br [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Centro de Engenharia Biomedica

    2014-08-15

    This paper evaluates the failure modes of the computerized planning step in interstitial implants with high dose rate brachytherapy. The prospective tool of risk management Health Care Failure Mode and Effects Analysis (HFMEA) was used. Twelve subprocesses were identified, and 33 failure modes of which 21 justified new safety actions, and 9 of them were intolerable risks. The method proved itself useful in identifying failure modes, but laborious and subjective in their assessment. The main risks were due to human factors, which require training and commitment of management to their mitigation. (author)

  7. Verification of the calculation program for brachytherapy planning system of high dose rate (PLATO); Programa de verificacion del calculo para un sistema de planificacion de braquiterapia de alta tasa de dosis (PLATO)

    Energy Technology Data Exchange (ETDEWEB)

    Almansa, J.; Alaman, C.; Perez-Alija, J.; Herrero, C.; Real, R. del; Ososrio, J. L.

    2011-07-01

    In our treatments are performed brachytherapy high dose rate since 2007. The procedures performed include gynecological intracavitary treatment and interstitial. The treatments are performed with a source of Ir-192 activity between 5 and 10 Ci such that small variations in treatment times can cause damage to the patient. In addition the Royal Decree 1566/1998 on Quality Criteria in radiotherapy establishes the need to verify the monitor units or treatment time in radiotherapy and brachytherapy. All this justifies the existence of a redundant system for brachytherapy dose calculation that can reveal any abnormality is present.

  8. In lower extremity PTAs intraluminal is better than subintimal.

    Science.gov (United States)

    Bosiers, M; Deloose, K; Callaert, J; Maene, L; Keirse, K; Verbist, J; Peeters, P

    2012-04-01

    With subintimal recanalization, a channel is deliberately created by dissecting the vessel wall in order to replace the native occluded lumen. This is opposed to intraluminal recanalization, where passage of an arterial obstructive lesion is performed by central luminal navigation. Both intraluminal and subintimal treatment has its proponents and adversaries. The appreciation of an investigator for a certain technique is commonly related to the training received and the personal experience. Yet, the intraluminal technique uses the clinically preferred route for adjunctive treatment, such as balloon angioplasty or stent deployment. A wide variety of devices designed to obtain intraluminal lesion passage is available and is currently being used in vascular centers worldwide. With intraluminal techniques, success rates of up to 95% have been reported.

  9. Systemic response of Korean dark-striped field mice, Apodenmus agrarius coreae after high-dose- rate γ-irradiation: Organ weights, hemato-chemistry, apoptosis of splenocytes and sperm

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Kwang Hee; Choi, Hoon; Joo, Hyun Jin; Kim, Hee Sun [Radiation Health Research Institute, KHNP, Gyeongju (Korea, Republic of); Keum, Dong Kwon [Nuclear Environment Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-11-15

    Since the territory of the radio-contaminated area is in homeogenous in radiation level and spectrum, investigation of the genetical mutation process in the natural animal populations inhabiting the radioontaminated areas will be provide a realistic picture of genetic effects for radiation exposure. However, little is known about the basic data such as systemic responses after ionizing radiation exposures in wild small rodents. Taking into account different radio-sensitivity of dark-striped field mice (A. a. coreae, THOMAS), the objective of the study is focus on investigate the level of systemic responses, included organ weights, hemato-chemistry and apoptosis in splenocytes and sperm of caudal epididymis after high-dose-rate irradiation especially as a potential biological dosimeter in radio-ecology. Figure 1 summarizes the results of the apoptotic events in spleen (data not shown at here) and in sperm of caudal epididymis at 24hrs after a single high-dose-rate γ-irradiation. The results of apoptosis in spleen and sperm caused by exposure to different doses of γ-irradiation are displayed. The data show that the field striped mice after irradiated with more than high dose of 0.5 Gy induces an significantly increased apoptosis. Results also shown that for exposure to 0.5 Gy, the apoptosis of both organs ware decreased compared to those of other γ-irradiated mice.

  10. Under Pressure: Intraluminal Filling Pressures of Postpartum Hemorrhage Tamponade Balloons.

    Science.gov (United States)

    Antony, Kathleen M; Racusin, Diana A; Belfort, Michael A; Dildy, Gary A

    2017-04-01

    Objective Uterine tamponade by fluid-filled balloons is now an accepted method of controlling postpartum hemorrhage. Available tamponade balloons vary in design and material, which affects the filling attributes and volume at which they rupture. We aimed to characterize the filling capacity and pressure-volume relationship of various tamponade balloons. Study Design Balloons were filled with water ex vivo. Intraluminal pressure was measured incrementally (every 10 mL for the Foley balloons and every 50 mL for all other balloons). Balloons were filled until they ruptured or until 5,000 mL was reached. Results The Foley balloons had higher intraluminal pressures than the larger-volume balloons. The intraluminal pressure of the Sengstaken-Blakemore tube (gastric balloon) was initially high, but it decreased until shortly before rupture occurred. The Bakri intraluminal pressure steadily increased until rupture occurred at 2,850 mL. The condom catheter, BT-Cath, and ebb all had low intraluminal pressures. Both the BT-Cath and the ebb remained unruptured at 5,000 mL. Conclusion In the setting of acute hemorrhage, expeditious management is critical. Balloons that have a low intraluminal pressure-volume ratio may fill more rapidly, more easily, and to greater volumes. We found that the BT-Cath, the ebb, and the condom catheter all had low intraluminal pressures throughout filling.

  11. Patient-specific Monte Carlo-based dose-kernel approach for inverse planning in afterloading brachytherapy.

    Science.gov (United States)

    D'Amours, Michel; Pouliot, Jean; Dagnault, Anne; Verhaegen, Frank; Beaulieu, Luc

    2011-12-01

    Brachytherapy planning software relies on the Task Group report 43 dosimetry formalism. This formalism, based on a water approximation, neglects various heterogeneous materials present during treatment. Various studies have suggested that these heterogeneities should be taken into account to improve the treatment quality. The present study sought to demonstrate the feasibility of incorporating Monte Carlo (MC) dosimetry within an inverse planning algorithm to improve the dose conformity and increase the treatment quality. The method was based on precalculated dose kernels in full patient geometries, representing the dose distribution of a brachytherapy source at a single dwell position using MC simulations and the Geant4 toolkit. These dose kernels are used by the inverse planning by simulated annealing tool to produce a fast MC-based plan. A test was performed for an interstitial brachytherapy breast treatment using two different high-dose-rate brachytherapy sources: the microSelectron iridium-192 source and the electronic brachytherapy source Axxent operating at 50 kVp. A research version of the inverse planning by simulated annealing algorithm was combined with MC to provide a method to fully account for the heterogeneities in dose optimization, using the MC method. The effect of the water approximation was found to depend on photon energy, with greater dose attenuation for the lower energies of the Axxent source compared with iridium-192. For the latter, an underdosage of 5.1% for the dose received by 90% of the clinical target volume was found. A new method to optimize afterloading brachytherapy plans that uses MC dosimetric information was developed. Including computed tomography-based information in MC dosimetry in the inverse planning process was shown to take into account the full range of scatter and heterogeneity conditions. This led to significant dose differences compared with the Task Group report 43 approach for the Axxent source. Copyright © 2011

  12. Patient-Specific Monte Carlo-Based Dose-Kernel Approach for Inverse Planning in Afterloading Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    D' Amours, Michel [Departement de Radio-Oncologie et Centre de Recherche en Cancerologie de l' Universite Laval, Hotel-Dieu de Quebec, Quebec, QC (Canada); Department of Physics, Physics Engineering, and Optics, Universite Laval, Quebec, QC (Canada); Pouliot, Jean [Department of Radiation Oncology, University of California, San Francisco, School of Medicine, San Francisco, CA (United States); Dagnault, Anne [Departement de Radio-Oncologie et Centre de Recherche en Cancerologie de l' Universite Laval, Hotel-Dieu de Quebec, Quebec, QC (Canada); Verhaegen, Frank [Department of Radiation Oncology, Maastro Clinic, GROW Research Institute, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Oncology, McGill University, Montreal, QC (Canada); Beaulieu, Luc, E-mail: beaulieu@phy.ulaval.ca [Departement de Radio-Oncologie et Centre de Recherche en Cancerologie de l' Universite Laval, Hotel-Dieu de Quebec, Quebec, QC (Canada); Department of Physics, Physics Engineering, and Optics, Universite Laval, Quebec, QC (Canada)

    2011-12-01

    Purpose: Brachytherapy planning software relies on the Task Group report 43 dosimetry formalism. This formalism, based on a water approximation, neglects various heterogeneous materials present during treatment. Various studies have suggested that these heterogeneities should be taken into account to improve the treatment quality. The present study sought to demonstrate the feasibility of incorporating Monte Carlo (MC) dosimetry within an inverse planning algorithm to improve the dose conformity and increase the treatment quality. Methods and Materials: The method was based on precalculated dose kernels in full patient geometries, representing the dose distribution of a brachytherapy source at a single dwell position using MC simulations and the Geant4 toolkit. These dose kernels are used by the inverse planning by simulated annealing tool to produce a fast MC-based plan. A test was performed for an interstitial brachytherapy breast treatment using two different high-dose-rate brachytherapy sources: the microSelectron iridium-192 source and the electronic brachytherapy source Axxent operating at 50 kVp. Results: A research version of the inverse planning by simulated annealing algorithm was combined with MC to provide a method to fully account for the heterogeneities in dose optimization, using the MC method. The effect of the water approximation was found to depend on photon energy, with greater dose attenuation for the lower energies of the Axxent source compared with iridium-192. For the latter, an underdosage of 5.1% for the dose received by 90% of the clinical target volume was found. Conclusion: A new method to optimize afterloading brachytherapy plans that uses MC dosimetric information was developed. Including computed tomography-based information in MC dosimetry in the inverse planning process was shown to take into account the full range of scatter and heterogeneity conditions. This led to significant dose differences compared with the Task Group report

  13. Concomitant chemoradiotherapy with high dose rate brachytherapy ...

    African Journals Online (AJOL)

    Tamer Refaat

    2011-06-12

    Jun 12, 2011 ... Generally, radiation therapy for cervical cancer consists of a combination of ...... breast, prostate, skin, lung, and pancreas, NF-jB nuclear expression .... Applicator reconstruction for HDR cervix treatment planning using images ...

  14. High dose rate brachytherapy source measurement intercomparison.

    Science.gov (United States)

    Poder, Joel; Smith, Ryan L; Shelton, Nikki; Whitaker, May; Butler, Duncan; Haworth, Annette

    2017-06-01

    This work presents a comparison of air kerma rate (AKR) measurements performed by multiple radiotherapy centres for a single HDR (192)Ir source. Two separate groups (consisting of 15 centres) performed AKR measurements at one of two host centres in Australia. Each group travelled to one of the host centres and measured the AKR of a single (192)Ir source using their own equipment and local protocols. Results were compared to the (192)Ir source calibration certificate provided by the manufacturer by means of a ratio of measured to certified AKR. The comparisons showed remarkably consistent results with the maximum deviation in measurement from the decay-corrected source certificate value being 1.1%. The maximum percentage difference between any two measurements was less than 2%. The comparisons demonstrated the consistency of well-chambers used for (192)Ir AKR measurements in Australia, despite the lack of a local calibration service, and served as a valuable focal point for the exchange of ideas and dosimetry methods.

  15. A new afterloading-applicator for primary brachytherapy of endometrial cancer. First clinical experiences. Neuentwicklung eines Afterloading-Applikators zur primaeren Behandlung des Endometriumkarzinoms. Erster klinischer Erfahrungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, M.; Schulz-Wendtland, R.; Richard, F. (Freiburg Univ. (Germany). Abt. Gynaekologische Radiologie); Hooft, E. van t' (Nucletron, Leersum (Netherlands))

    1991-09-01

    Presented is a new afterloading applicator used for primary brachytherapy of endometrial cancer. The advantages: The afterloading applicator holds six afterloading tubes which bundled together in a cover. After the cover is pulled back, the individual tubes expand as a result of the sleeve shape and of the inherent stress of the plastic material used and make direct contact with the endometrium and with the tumor. The applicator is 8 mm in diameter which means that the cervix has to be dilated to Hegar 8 or 9. Radiation planning is done on the basis of orthogonal localisation X-rays or MR. The newly designed applicator can be used for both HDR and LDR afterloading procedures. We have clinical experiences in 42 applications. (orig.).

  16. Unresectable colorectal liver metastases. Percutaneous ablation using CT-guided high-dose-rate brachytherapy (CT-HDBRT); Nicht resektable kolorektale Lebermetastasen. Perkutane Ablation mittels CT-gesteuerter Hochdosisbrachytherapie (CT-HDBRT)

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, F.; Lutter, A.; Schnapauff, D.; Denecke, T.; Gebauer, B. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Hildebrandt, B. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Oncology; Puhl, G. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of General, Visceral and Transplantation Surgery; Wust, P. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Radiation Oncology

    2014-06-15

    Purpose: To evaluate the clinical outcome of CT-guided high-dose-rate brachytherapy (CT-HDRBT) of unresectable colorectal liver metastases (CRLMs). Materials and Methods: Retrospective analysis of all consecutive patients with unresectable CRLMs treated with CT-HDRBT between January 2008 and November 2012. Treatment was performed by CT-guided catheter placement and high-dose-rate brachytherapy with an iridium-192 source. MRI follow-up was performed after 6 weeks and then every 3 months post-intervention. The primary endpoint was local tumor control (LTC); secondary endpoints included time to progression (TTP) and overall survival (OS). Results: 80 heavily pretreated patients with 179 metastases were available for MRI evaluation for a mean follow-up time of 16.9 months. The mean tumor diameter was 28.5 mm (range: 8 - 107 mm). No major complications were observed. A total of 23 (12.9%) local tumor progressions were observed. Lesions ≥ 4 cm in diameter showed significantly more local progression than smaller lesions (< 4 cm). 50 patients (62.5%) experienced systemic tumor progression. The median TTP was 6 months. 28 (43%) patients died during the follow-up period. The median OS after ablation was 18 months. Conclusion: CT-HDRBT is an effective technique for the treatment of unresectable CRLMs and warrants promising LTC rates compared to thermal ablative techniques. A combination with other local and systemic therapies should be evaluated in patients with lesions > 4 cm in diameter, in which higher progression rates are expected. (orig.)

  17. SU-F-P-39: End-To-End Validation of a 6 MV High Dose Rate Photon Beam, Configured for Eclipse AAA Algorithm Using Golden Beam Data, for SBRT Treatments Using RapidArc

    Energy Technology Data Exchange (ETDEWEB)

    Ferreyra, M; Salinas Aranda, F; Dodat, D; Sansogne, R; Arbiser, S [Vidt Centro Medico, Ciudad Autonoma De Buenos Aires, Ciudad Autonoma de Buenos Aire (Argentina)

    2016-06-15

    Purpose: To use end-to-end testing to validate a 6 MV high dose rate photon beam, configured for Eclipse AAA algorithm using Golden Beam Data (GBD), for SBRT treatments using RapidArc. Methods: Beam data was configured for Varian Eclipse AAA algorithm using the GBD provided by the vendor. Transverse and diagonals dose profiles, PDDs and output factors down to a field size of 2×2 cm2 were measured on a Varian Trilogy Linac and compared with GBD library using 2% 2mm 1D gamma analysis. The MLC transmission factor and dosimetric leaf gap were determined to characterize the MLC in Eclipse. Mechanical and dosimetric tests were performed combining different gantry rotation speeds, dose rates and leaf speeds to evaluate the delivery system performance according to VMAT accuracy requirements. An end-to-end test was implemented planning several SBRT RapidArc treatments on a CIRS 002LFC IMRT Thorax Phantom. The CT scanner calibration curve was acquired and loaded in Eclipse. PTW 31013 ionization chamber was used with Keithley 35617EBS electrometer for absolute point dose measurements in water and lung equivalent inserts. TPS calculated planar dose distributions were compared to those measured using EPID and MapCheck, as an independent verification method. Results were evaluated with gamma criteria of 2% dose difference and 2mm DTA for 95% of points. Results: GBD set vs. measured data passed 2% 2mm 1D gamma analysis even for small fields. Machine performance tests show results are independent of machine delivery configuration, as expected. Absolute point dosimetry comparison resulted within 4% for the worst case scenario in lung. Over 97% of the points evaluated in dose distributions passed gamma index analysis. Conclusion: Eclipse AAA algorithm configuration of the 6 MV high dose rate photon beam using GBD proved efficient. End-to-end test dose calculation results indicate it can be used clinically for SBRT using RapidArc.

  18. 10 CFR 35.647 - Additional technical requirements for mobile remote afterloader units.

    Science.gov (United States)

    2010-01-01

    ... on the remote afterloader unit, on the control console, and in the facility; (3) Viewing and intercom... 10 Energy 1 2010-01-01 2010-01-01 false Additional technical requirements for mobile remote... MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic...

  19. [Treatment of atherosclerosis. New percutaneous intraluminal techniques].

    Science.gov (United States)

    Lablanche, J M

    1990-10-06

    Balloon-catheter angioplasty was introduced by Gruntzig in 1977 and has since proved effective, but 3 problems are still encountered: immediate reobstruction, restenosis during the first 3 months and extension of the procedure to a greater number of cases. In an attempt to solve these problems, other percutaneous/technics, associated or not with balloon angioplasty, have been devised. They are: (1) intraluminal stents which perfectly keep the vessel open after balloon angioplasty; (2) vaporization of atheromatous plaques by laser, and notably excimer laser which results in immediate recanalization, later completed by balloon angioplasty; (3) heating balloons which stick dissections and improve the immediate success rate; (4) atheroma-cutting and storing systems, such as Simpson's atherocath, cutting and aspirating systems, such as Stack's transluminal extraction catheter, or erasing systems, such as Auth's rotablator; (5) other sources of energy, such as ultrasounds, microwaves and radiofrequencies, will perhaps, be used in the near future. None of these new technics has solved the restenosis problem, but all have proved effective in suppressing the obstacle, there by giving hopes of reducing immediate complications and gradually widening the indications of percutaneous revascularization.

  20. A quality indicator to evaluate high-dose-rate intracavitary brachytherapy for cancer of the cervix; Determinacao de um indicador de qualidade para avaliar a braquiterapia intracavitaria com alta taxa de dose no cancer do colo uterino

    Energy Technology Data Exchange (ETDEWEB)

    Morales, Francisco Contreras; Soboll, Daniel Scheidegger [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radioterapia. Servico de Fisica Medica

    2000-12-01

    The aim of this report is to prevent a simple quality indicator (QI) that can be promptly used to evaluate the high-dose-rate (HDR) intracavitary brachytherapy for the treatment of cancer of the cervix, and if necessary, to correct applicators' geometry before starting the treatment. We selected 51 HDR intracavitary applications of brachytherapy of patients with carcinoma of the cervix treated with 60 mm uterine tandem and small Fletcher colpostat, according to the Manchester method (dose prescription on point A). A QI was defined as the ratio between the volume of 100% isodose curve of the study insertion and the volume of the 100% isodose curve of an insertion considered to be ideal. The data obtained were distributed in three groups: the group with tandem placement slippage (67,5%), a group with colpostat placement slippage (21,9%), and a third group, considered normal (10,6%). Each group showed particular characteristics (p < 0.0001). QI can be the best auxiliary method to establish the error tolerance (%) allowed for HDR intracavitary brachytherapy. (author)

  1. High-dose rate brachytherapy in the treatment of prostate cancer: acute toxicity and biochemical behavior analysis; Braquiterapia de alta taxa de dose no tratamento do carcinoma da prostata: analise da toxicidade aguda e do comportamento bioquimico

    Energy Technology Data Exchange (ETDEWEB)

    Esteves, Sergio Carlos Barros; Oliveira, Antonio Carlos Zuliani de; Cardoso, Herbeni; Tagawa, Eduardo Komai; Castelo, Roberto [Beneficencia Portuguesa de Sao Paulo, SP (Brazil). Hospital Sao Joaquim. Servico de Radioterapia]. E-mail: estevesrt@uol.com.br; D' Imperio, Marcio [Beneficencia Portuguesa de Sao Paulo, SP (Brazil). Hospital Sao Joaquim. Servico de Urologia

    2006-03-15

    Objective: this study focuses on the biochemical response of the following variables: prostate volume, prostate-specific antigen (PSA) value, Gleason scores, staging, the risk of the disease, and hormone therapy. Objective: in the period between February of 1998 and July of 2001, 46 patients with prostate cancer were treated with radiotherapy, in a combination of teletherapy and high-dose rate (HDR) brachytherapy. The age ranged from 51 to 79 years (averaging 66.4 years). T1c stage was the most frequent one: 30 (65%). The Gleason score was below 7 in 78% of the patients. PSA ranged from 3.4 to 33.3, being below 10 in 39% of the cases. The average prostatic volume was 32.3 cc. Twenty-eight percent of the patients received hormone therapy. Teletherapy dose ranged from 45 to 50.4 Gy, associated to four fractions of 4 Gy of HDR brachytherapy. Results: the follow-up period varied from 6 to 43 months. Four patients missed the follow-up and four died (one due to the disease). Out of the 39 patients that were analyzed, 76% presented a less than 1.5 PSA. None of the analyzed variables were found to be of statistical significance (p > 0.05) regarding biochemical control. Conclusion: the use of HDR brachytherapy was found to be effective in the treatment of prostate cancer and, in this study, the variables considered as prognostic factors did not interfere in the biochemical control. (author)

  2. Intraluminal crawling versus interstitial neutrophil migration during inflammation.

    Science.gov (United States)

    Pick, Robert; Brechtefeld, Doris; Walzog, Barbara

    2013-08-01

    Site-directed trafficking of polymorphonuclear neutrophils (PMN) to their target regions within the tissue is an important prerequisite for efficient host defense during the acute inflammatory response. This process requires intraluminal crawling of PMN on the activated endothelial cells to their extravasation sites. Upon transendothelial diapedesis, PMN migrate in the interstitial tissue to sites of inflammation. These crucial steps within the recruitment cascade are defined as intraluminal crawling and interstitial migration. In this review, we will focus on the molecular mechanisms that control and fine-tune these migratory processes and discuss the role of adhesion molecules of the β2 integrin (CD11/CD18) family for these cellular functions.

  3. High dose-rate brachytherapy as a treatment option in primary tracheal tumors Braquiterapia de alta taxa de dose como opção terapêutica nos tumores primários da traquéia

    Directory of Open Access Journals (Sweden)

    Heloisa de Andrade Carvalho

    2005-08-01

    Full Text Available PURPOSE: To present experience with high dose-rate endobronchial brachytherapy in the treatment of primary tracheal tumors. PATIENTS AND METHODS: Four patients with nonresected primary tracheal tumors are presented: 2 cases of squamous cell carcinoma of the trachea, 1 of recurrent adenoid cystic carcinoma, and 1 with recurrent plasmacytoma. All received brachytherapy, alone or as a boost for primary irradiation, in 3 or 4 fractions of 7.5 Gy, calculated at a depth of 1 cm. Follow-up was considered to start from the end of brachytherapy. RESULTS: Local control was achieved in all cases at the time of first bronchoscopic evaluation. Two patients with squamous cell carcinoma died at 6th and 33rd months after brachytherapy, respectively. The first had no evidence of disease, and the latter had local recurrence. The other 2 patients were alive after 64 and 110 months of follow-up, respectively, both with no evidence of disease. Tracheal stenosis developed in these 2 cases, 22 and 69 months after brachytherapy. Tracheal stent placement was needed only for the patient with an adenoid cystic carcinoma. CONCLUSIONS: Endobronchial high dose-rate brachytherapy may be used for tracheal tumors, even as a boost for external beam irradiation, or in recurrences. Local control in 3 out of 4 patients indicates that individual cases may benefit from the treatment. Long-term survival may also be expected, mainly for tumors with adenoid cystic histology.OBJETIVO: Apresentar a experiência do tratamento de 4 pacientes com tumores primários de traquéia, não operados, submetidos à braquiterapia endobrônquica de alta taxa de dose. PACIENTES E MÉTODOS: Dois casos de carcinoma espinocelular, uma recidiva de carcinoma adenóide cístico e uma recidiva de plasmocitoma primário da traquéia. Todos receberam braquiterapia endobrônquica, exclusiva ou como reforço de dose da radioterapia externa. Foram administradas 3 ou 4 frações de 7,5 Gy cada, calculados a 1 cm de

  4. Computed Tomography–Guided Interstitial High-Dose-Rate Brachytherapy in Combination With Regional Positive Lymph Node Intensity-Modulated Radiation Therapy in Locally Advanced Peripheral Non–Small Cell Lung Cancer: A Phase 1 Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Xiang, Li; Zhang, Jian-wen; Lin, Sheng; Luo, Hui-Qun; Wen, Qing-Lian; He, Li-Jia; Shang, Chang-Ling; Ren, Pei-Rong; Yang, Hong-Ru; Pang, Hao-Wen; Yang, Bo; He, Huai-Lin [Department of Oncology, Affiliated Hospital of Luzhou Medical College, Luzhou (China); Chen, Yue, E-mail: chenyue5523@126.com [Department of Nuclear Medicine, Affiliated Hospital of Luzhou Medical College, Luzhou (China); Wu, Jing-Bo, E-mail: wjb6147@163.com [Department of Oncology, Affiliated Hospital of Luzhou Medical College, Luzhou (China)

    2015-08-01

    Purpose: To assess the technical safety, adverse events, and efficacy of computed tomography (CT)-guided interstitial high-dose-rate (HDR) brachytherapy in combination with regional positive lymph node intensity modulated radiation therapy in patients with locally advanced peripheral non–small cell lung cancer (NSCLC). Methods and Materials: Twenty-six patients with histologically confirmed NSCLC were enrolled in a prospective, officially approved phase 1 trial. Primary tumors were treated with HDR brachytherapy. A single 30-Gy dose was delivered to the 90% isodose line of the gross lung tumor volume. A total dose of at least 70 Gy was administered to the 95% isodose line of the planning target volume of malignant lymph nodes using 6-MV X-rays. The patients received concurrent or sequential chemotherapy. We assessed treatment efficacy, adverse events, and radiation toxicity. Results: The median follow-up time was 28 months (range, 7-44 months). There were 3 cases of mild pneumothorax but no cases of hemothorax, dyspnea, or pyothorax after the procedure. Grade 3 or 4 acute hematologic toxicity was observed in 5 patients. During follow-up, mild fibrosis around the puncture point was observed on the CT scans of 2 patients, but both patients were asymptomatic. The overall response rates (complete and partial) for the primary mass and positive lymph nodes were 100% and 92.3%, respectively. The 1-year and 2-year overall survival (OS) rates were 90.9% and 67%, respectively, with a median OS of 22.5 months. Conclusion: Our findings suggest that HDR brachytherapy is safe and feasible for peripheral locally advanced NSCLC, justifying a phase 2 clinical trial.

  5. Impact of intraoperative MRI/TRUS fusion on dosimetric parameters in cT3a prostate cancer patients treated with high-dose-rate real-time brachytherapy.

    Science.gov (United States)

    Gomez-Iturriaga, Alfonso; Crook, Juanita; Casquero, Francisco; Carvajal, Claudia; Urresola, Arantxa; Canteli, Begoña; Ezquerro, Ana; Hortelano, Eduardo; Cacicedo, Jon; Espinosa, Jose Maria; Perez, Fernando; Minguez, Pablo; Bilbao, Pedro

    2014-06-01

    The purpose of this study was to evaluate the impact of intraoperative MRI/TRUS fusion procedure in cT3a prostate cancer patients treated with high-dose-rate (HDR) real-time brachytherapy. Prostate gland, dominant intraprostatic lesions (DILs), and extracapsular extension (ECE) were delineated in the pre-brachytherapy magnetic resonance images (MRI) of 9 consecutive patients. The pre-implant P-CTVUS (prostate clinical target volume) was defined as the prostate seen in the transrectal ultrasound (TRUS) images. The CTVMR includedthe prostate with the ECE image (ECE-CTV) as defined on the MRI. Two virtual treatment plans were performed based on the MRI/TRUS fusion images, the first one prescribing 100% of the dose to the P-PTVUS, and the second prescribing to the PTVMR. The implant parameters and dose-volume histogram (DVH) related parameters of the prostate, OARs, and ECE were compared between both plans. Mean radial distance of ECE was 3.6 mm (SD: 1.1). No significant differences were found between prostate V100, V150, V200, and OARs DVH-related parameters between the plans. Mean values of ECE V100, V150, and V200 were 85.9% (SD: 15.1), 18.2% (SD: 17.3), and 5.85% (SD: 7) when the doses were prescribed to the PTVUS, whereas ECE V100, V150, and V200 were 99.3% (SD: 1.2), 45.8% (SD: 22.4), and 19.6% (SD: 12.6) when doses were prescribed to PTVMR (p = 0.028, p = 0.002 and p = 0.004, respectively). TRUS/MRI fusion provides important information for prostate brachytherapy, allowing for better coverage and higher doses to extracapsular disease in patients with clinical stage T3a.

  6. The effect of rib and lung heterogeneities on the computed dose to lung in Ir-192 high-dose-rate breast brachytherapy: Monte Carlo versus a treatment planning system.

    Science.gov (United States)

    Yazdi, Hossein Salehi; Shamsaei, Mojtaba; Jaberi, Ramin; Shabani, Hamid Reza; Allahverdi, Mahmoud; Vaezzadeh, Seyed Ali

    2012-01-01

    This study investigates to what extent the dose received by lungs from a commercially available treatment planning system, Ir-192 high-dose-rate (HDR), in breast brachytherapy, is accurate, with the emphasis on tissue heterogeneities, and taking into account the presence of ribs, in dose delivery to the lung. A computed tomography (CT) scan of a breast was acquired and transferred to the 3-D treatment planning system and was also used to construct a patient-equivalent phantom. An implant involving 13 plastic catheters and 383 programmed source dwell positions were simulated, using the Monte Carlo N-Particle eXtended (MCNPX) code. The Monte Carlo calculations were compared with the corresponding commercial treatment planning system (TPS) in the form of percentage isodose and cumulative dose-volume histogram (DVH) in the breast, lungs, and ribs. The comparison of the Monte Carlo results and the TPS calculations showed that a percentage of isodose greater than 75% in the breast, which was located rather close to the implant or away from the breast curvature surface and lung boundary, were in good agreement. TPS calculations overestimated the dose to the lung for lower isodose contours that were lying near the breast surface and the boundary of breast and lung and were relatively away from the implant. Taking into account the ribs and entering the actual data for breasts, ribs, and lungs, revealed an average overestimation of the dose by a factor of 8% in the lung for TPS calculations. Therefore, the accuracy of the TPS results may be limited to regions near the implants where the treatment is planned, and is a more conservative approach for regions at boundaries with curvatures or tissues with a different material than that in the breast.

  7. Triple-tandem high-dose-rate brachytherapy for early-stage medically inoperable endometrial cancer: Initial report on acute toxicity and dosimetric comparison to stereotactic body radiation therapy.

    Science.gov (United States)

    Kauffmann, Greg; Wu, Tianming; Al-Hallaq, Hania; Hasan, Yasmin

    Stereotactic body radiotherapy (SBRT) may be appealing in medically inoperable endometrial cancer to avoid procedural risks. We performed a dosimetric comparison to triple-tandem, high-dose-rate (HDR) brachytherapy. Six consecutive clinical stage I, grade 1-2, medically inoperable endometrial cancer patients were treated with triple-tandem HDR brachytherapy. We report patient factors and acute toxicity. Also, we performed dosimetric comparison to SBRT using both 3D conformal arc (3DArc) and volumetric-modulated arc therapy. D2cc values for normal tissues were calculated and compared to the HDR plans. Median age was 57 years. Patient comorbidities included morbid obesity, congestive heart failure, diabetes, and pulmonary emboli. In three patients who received prior external beam radiation (EBRT), median EBRT and HDR doses were 46 Gy and 20 Gy, respectively. The median dose with HDR brachytherapy monotherapy was 35 Gy. Acute toxicities during EBRT included gastrointestinal (3/3 with grade 1-2) and genitourinary (3/3 with grade 1-2). Acute toxicities during HDR brachytherapy were gastrointestinal (2/6 total with grade 1-2) and genitourinary (2/6 total with grade 1). The mean D2cc/Gy of prescription dose for rectum, sigmoid, and bladder were 0.58, 0.40, and 0.47 respectively. Overall, doses to normal tissues were higher for SBRT plans as compared to HDR. Also, the R50 (ratio of the 50% prescription isodose volume to the PTV) was lowest with HDR brachytherapy. In medically inoperable, clinical stage I endometrial cancer patients with multiple comorbidities, definitive triple-tandem, HDR brachytherapy results in mild acute toxicity. In addition, HDR brachytherapy achieves relatively lower doses to surrounding normal tissues as compared to SBRT. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  8. Acute and late vaginal toxicity after adjuvant high-dose-rate vaginal brachytherapy in patients with intermediate risk endometrial cancer: is local therapy with hyaluronic acid of clinical benefit?

    Science.gov (United States)

    Delishaj, Durim; Fabrini, Maria Grazia; Gonnelli, Alessandra; Morganti, Riccardo; Perrone, Franco; Tana, Roberta; Paiar, Fabiola; Gadducci, Angiolo

    2016-01-01

    Purpose The aim of the present study was to evaluate the effectiveness of hyaluronic acid (HA) in the prevention of acute and late vaginal toxicities after high-dose-rate (HDR) vaginal brachytherapy (BT). Material and methods Between January 2011 and January 2015, we retrospectively analyzed 126 patients with endometrial cancer who underwent extrafascial hysterectomy with or without lymphadenectomy and adjuvant HDR-vaginal BT +/– adjuvant chemotherapy. The total dose prescription was 21 Gy in 3 fractions (one fraction for week). Vaginal ovules containing 5 mg of HA were given for whole duration of vaginal BT and for the two following weeks. Acute and late toxicities were evaluated according to CTCAE vs 4.02. Results According to the revised FIGO 2009 classification, most tumors were in stage IA (30.9%) and in stage IB (57.9%). Thirty-three patients (26.2%) received adjuvant chemotherapy before vaginal BT. Five-year disease-free survival (DFS) and five-year overall survival (OS) were 88% and 93%, respectively. The most common grade 1-2 acute toxicities were vaginal inflammation (18 patients, 14.3%) and dyspareunia (7 patients, 5.5%). Two patients (1.6%) had more than one toxicity. Late toxicity occurred in 20 patients (15.9%). Grade 1-2 late toxicities were fibrosis (14 patients, 11.1%) and telangiectasias (7 patients, 5.5%). Six patients (4.8%) had more than one late toxicity. No grade 3 or higher acute or late toxicities were observed. Conclusions These results appear to suggest that the local therapy with HA is of clinical benefit for intermediate risk endometrial cancer patients who receive adjuvant HDR-vaginal BT after surgery. A randomized trial comparing HA treatment vs. no local treatment in this clinical setting is warranted to further evaluate the efficacy of HA in preventing vaginal BT-related vaginal toxicity. PMID:28115957

  9. Single-fraction high-dose-rate brachytherapy using real-time transrectal ultrasound based planning in combination with external beam radiotherapy for prostate cancer: dosimetrics and early clinical results

    Science.gov (United States)

    Lauche, Olivier; Delouya, Guila; Taussky, Daniel; Menard, Cynthia; Béliveau-Nadeau, Dominic; Hervieux, Yannick; Larouche, Renée

    2016-01-01

    Purpose To validate the feasibility of a single-fraction high-dose-rate brachytherapy (HDRBT) boost for prostate cancer using real-time transrectal ultrasound (TRUS) based planning. Material and methods From August 2012 to September 2015, 126 patients underwent a single-fraction HDRBT boost of 15 Gy using real-time TRUS based planning. External beam radiation therapy (EBRT) (37.5 Gy/15 fractions, 44 Gy/22 fractions, or 45 Gy/25 fractions) was performed before (31%) or after (69%) HDRBT boost. Genito-urinary (GU) and gastro-intestinal (GI) toxicity were assessed 4 and 12 months after the end of combined treatment using the international prostate symptom score scale (IPSS) and the common terminology criteria for adverse events (CTCAE) v3.0. Results All dose-planning objectives were achieved in 90% of patients. Prostate D90 ≥ 105% and ≤ 115% was achieved in 99% of patients, prostate V150 ≤ 40% in 99%, prostate V200 < 11% in 96%, urethra D10 < 120% for 99%, urethra V125 = 0% in 100%, and rectal V75 < 1 cc in 93% of patients. Median IPSS score was 4 at baseline and did not change at 4 and 12 months after combined treatment. No patients developed ≥ grade 2 GI toxicity. With a median follow-up of 10 months, only two patients experienced biochemical failure. Among patients who didn't receive ADT, cumulative percentage of patients with PSA ≤ 1 ng/ml at 4 and 18 months was respectively 23% and 66%. Conclusions Single-fraction HDRBT boost of 15 Gy using real-time TRUS based planning achieves consistently high dosimetry quality. In combination with EBRT, toxicity outcomes appear promising. A longer follow-up is needed to assess long-term outcome and toxicities. PMID:27257413

  10. Cervical gross tumor volume dose predicts local control using magnetic resonance imaging/diffusion-weighted imaging-guided high-dose-rate and positron emission tomography/computed tomography-guided intensity modulated radiation therapy.

    Science.gov (United States)

    Dyk, Pawel; Jiang, Naomi; Sun, Baozhou; DeWees, Todd A; Fowler, Kathryn J; Narra, Vamsi; Garcia-Ramirez, Jose L; Schwarz, Julie K; Grigsby, Perry W

    2014-11-15

    Magnetic resonance imaging/diffusion weighted-imaging (MRI/DWI)-guided high-dose-rate (HDR) brachytherapy and (18)F-fluorodeoxyglucose (FDG) - positron emission tomography/computed tomography (PET/CT)-guided intensity modulated radiation therapy (IMRT) for the definitive treatment of cervical cancer is a novel treatment technique. The purpose of this study was to report our analysis of dose-volume parameters predicting gross tumor volume (GTV) control. We analyzed the records of 134 patients with International Federation of Gynecology and Obstetrics stages IB1-IVB cervical cancer treated with combined MRI-guided HDR and IMRT from July 2009 to July 2011. IMRT was targeted to the metabolic tumor volume and lymph nodes by use of FDG-PET/CT simulation. The GTV for each HDR fraction was delineated by use of T2-weighted or apparent diffusion coefficient maps from diffusion-weighted sequences. The D100, D90, and Dmean delivered to the GTV from HDR and IMRT were summed to EQD2. One hundred twenty-five patients received all irradiation treatment as planned, and 9 did not complete treatment. All 134 patients are included in this analysis. Treatment failure in the cervix occurred in 24 patients (18.0%). Patients with cervix failures had a lower D100, D90, and Dmean than those who did not experience failure in the cervix. The respective doses to the GTV were 41, 58, and 136 Gy for failures compared with 67, 99, and 236 Gy for those who did not experience failure (PD100, D90, and Dmean doses required for ≥90% local control to be 69, 98, and 260 Gy (P<.001). Total dose delivered to the GTV from combined MRI-guided HDR and PET/CT-guided IMRT is highly correlated with local tumor control. The findings can be directly applied in the clinic for dose adaptation to maximize local control. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. High-dose-rate brachytherapy with local injection of bleomycin for N0 oral tongue cancer. Possibilities of the control of tumor implant by inserting applicators and the decrease in tumor dose

    Energy Technology Data Exchange (ETDEWEB)

    Ohga, Saiji; Uehara, Satoru [National Kyushu Medical Center Hospital, Fukuoka (Japan); Miyoshi, Makoto [Kitakyushu Municipal Medical Center Hospital, Fukuoka (Japan); Jingu, Kenichi [Fukuoka Univ. (Japan). School of Medicine

    2003-01-01

    Twenty-eight patients with N0 oral tongue cancer were treated with high-dose-rate (HDR) interstitial brachytherapy combined with local injection of bleomycin between December 1997 and June 2001 at the Department of Radiology, National Kyushu Medical Center Hospital. A median dose of 5 mg of bleomycin was injected locally, and 16-20 Gy was delivered to the area surrounding applicators for control of the tumor implant during the initial two days. The two-year local recurrence-free survival rate was 96% [T1, 2: 100% (8/8, 15/15), T3: 80% (4/5)]. The two-year secondary neck node metastasis rate was 7.1% [T1: 12.5% (1/8), T2: 6.7% (1/15), T3: 0% (0/5)]. There were no tumor implants in any patients. We tried to decrease the minimal tumor dose step by step. The groups with median minimal tumor doses of 60 Gy, 50 Gy, and 40 Gy had local recurrence rates of 12.5% (1/8), 0% (0/14), and 0% (0/6), respectively. Local recurrence rates were not increased by decreasing the minimal tumor dose. Two patients (7%) had secondary neck node metastasis. Late adverse effects were tongue ulcer: 11% (3/28), oral floor ulcer: 4% (1/28), and osteonecrosis: 4% (1/28). These results suggest that control of the tumor implant and the decrease in minimal tumor dose below 60 Gy may be possible with the local injection of bleomycin and delivery of doses to the area surrounding the applicators when N0 tongue cancer is treated using {sup 192}Ir-HDR brachytherapy. (author)

  12. Validation of Intraluminal and Intraperitoneal microdialysis in ischemic small intestine

    DEFF Research Database (Denmark)

    Pynnönen, Lauri; Minkkinen, Minna; Perner, Anders;

    2013-01-01

    We sought to define the sensitivity and specificity of intraperitoneal (IP) and intraluminal (IL) microdialysate metabolites in depicting ex vivo small intestinal total ischemia during GI-tract surgery. We hypothesized that IL as opposed to IP microdialysis detects small intestinal ischemia...

  13. BRONCHOSCOPIC THERAPY IN PATIENTS WITH INTRALUMINAL TYPICAL BRONCHIAL CARCINOID

    NARCIS (Netherlands)

    SUTEDJA, TG; SCHREURS, AJ; VANDERSCHUEREN, RG; KWA, B; VANDERWERF, TS; POSTMUS, PE

    1995-01-01

    Objective: To study the efficacy of bronchoscopic therapy in patients with intraluminal typical bronchial carcinoid. Design: Retrospective analysis of the data of patients with bronchial carcinoid, treated primarily with bronchoscopic techniques such as Nd-YAG laser in various hospitals in the Nethe

  14. Prospective Multi-Institutional Study of Definitive Radiotherapy With High-Dose-Rate Intracavitary Brachytherapy in Patients With Nonbulky (<4-cm) Stage I and II Uterine Cervical Cancer (JAROG0401/JROSG04-2)

    Energy Technology Data Exchange (ETDEWEB)

    Toita, Takafumi, E-mail: b983255@med.u-ryukyu.ac.jp [Department of Radiology, Graduate School of Medical Science, University of Ryukyus, Okinawa (Japan); Kato, Shingo [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan); Niibe, Yuzuru [Department of Radiology, School of Medicine, Kitasato University, Sagamihara (Japan); Ohno, Tatsuya [Gunma University Heavy Ion Medical Center, Maebashi (Japan); Kazumoto, Tomoko [Department of Radiology, Saitama Cancer Center, Saitama (Japan); Kodaira, Takeshi [Department of Radiation Oncology, Aichi Cancer Center, Nagoya (Japan); Kataoka, Masaaki [Department of Radiology, National Shikoku Cancer Center, Ehime (Japan); Shikama, Naoto [Department of Radiation Oncology, Saku Central Hospital, Saku (Japan); Kenjo, Masahiro [Department of Radiation Oncology, Graduate School of Medical Science, Hiroshima University, Hiroshima (Japan); Tokumaru, Sunao [Department of Radiology, Saga University, Saga (Japan); Yamauchi, Chikako [Department of Radiation Oncology, Shiga Medical Center for Adults, Moriyama (Japan); Suzuki, Osamu [Department of Radiation Oncology, Osaka Medical Center for Cancer, Osaka (Japan); Sakurai, Hideyuki [Proton Medical Research Center and Tsukuba University, Tsukuba (Japan); Numasaki, Hodaka; Teshima, Teruki [Department of Medical Physics and Engineering, Graduate School of Medicine, Osaka University, Suita, Osaka (Japan); Oguchi, Masahiko [Department of Radiation Oncology, Cancer Institute Hospital, Tokyo (Japan); Kagami, Yoshikazu [Radiation Oncology Division, National Cancer Center Hospital, Tokyo (Japan); Nakano, Takashi [Department of Radiation Oncology, Gunma University, Graduate School of Medicine, Maebashi (Japan); Hiraoka, Masahiro [Department of Radiation Oncology and Image-applied Therapy, Kyoto University, Graduate School of Medicine, Kyoto (Japan); Mitsuhashi, Norio [Department of Radiation Oncology, Tokyo Women' s Medical University, Tokyo (Japan)

    2012-01-01

    Purpose: To determine the efficacy of a definitive radiotherapy protocol using high-dose-rate intracavitary brachytherapy (HDR-ICBT) with a low cumulative dose schedule in nonbulky early-stage cervical cancer patients, we conducted a prospective multi-institutional study. Methods and Materials: Eligible patients had squamous cell carcinoma of the intact uterine cervix, Federation of Gynecologic Oncology and Obstetrics (FIGO) stages Ib1, IIa, and IIb, tumor size <40 mm in diameter (assessed by T2-weighted magnetic resonance imaging), and no pelvic/para-aortic lymphadenopathy. The treatment protocol consisted of whole-pelvis external beam radiotherapy (EBRT) of 20 Gy/10 fractions, pelvic EBRT with midline block of 30 Gy/15 fractions, and HDR-ICBT of 24 Gy/4 fractions (at point A). The cumulative biologically effective dose (BED) was 62 Gy{sub 10} ({alpha}/{beta} = 10) at point A. The primary endpoint was the 2-year pelvic disease progression-free (PDPF) rate. All patients received a radiotherapy quality assurance review. Results: Between September 2004 and July 2007, 60 eligible patients were enrolled. Thirty-six patients were assessed with FIGO stage Ib1; 12 patients with stage IIa; and 12 patients with stage IIb. Median tumor diameter was 28 mm (range, 6-39 mm). Median overall treatment time was 43 days. Median follow-up was 49 months (range, 7-72 months). Seven patients developed recurrences: 3 patients had pelvic recurrences (2 central, 1 nodal), and 4 patients had distant metastases. The 2-year PDPF was 96% (95% confidence interval [CI], 92%-100%). The 2-year disease-free and overall survival rates were 90% (95% CI, 82%-98%) and 95% (95% CI, 89%-100%), respectively. The 2-year late complication rates (according to Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer of Grade {>=}1) were 18% (95% CI, 8%-28%) for large intestine/rectum, 4% (95% CI, 0%-8%) for small intestine, and 0% for bladder. No Grade {>=}3 cases were

  15. Prostate Specific Antigen (PSA as Predicting Marker for Clinical Outcome and Evaluation of Early Toxicity Rate after High-Dose Rate Brachytherapy (HDR-BT in Combination with Additional External Beam Radiation Therapy (EBRT for High Risk Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Thorsten H. Ecke

    2016-11-01

    Full Text Available High-dose-rate brachytherapy (HDR-BT with external beam radiation therapy (EBRT is a common treatment option for locally advanced prostate cancer (PCa. Seventy-nine male patients (median age 71 years, range 50 to 79 with high-risk PCa underwent HDR-BT following EBRT between December 2009 and January 2016 with a median follow-up of 21 months. HDR-BT was administered in two treatment sessions (one week interval with 9 Gy per fraction using a planning system and the Ir192 treatment unit GammaMed Plus iX. EBRT was performed with CT-based 3D-conformal treatment planning with a total dose administration of 50.4 Gy with 1.8 Gy per fraction and five fractions per week. Follow-up for all patients was organized one, three, and five years after radiation therapy to evaluate early and late toxicity side effects, metastases, local recurrence, and prostate-specific antigen (PSA value measured in ng/mL. The evaluated data included age, PSA at time of diagnosis, PSA density, BMI (body mass index, Gleason score, D’Amico risk classification for PCa, digital rectal examination (DRE, PSA value after one/three/five year(s follow-up (FU, time of follow-up, TNM classification, prostate volume, and early toxicity rates. Early toxicity rates were 8.86% for gastrointestinal, and 6.33% for genitourinary side effects. Of all treated patients, 84.81% had no side effects. All reported complications in early toxicity were grade 1. PSA density at time of diagnosis (p = 0.009, PSA on date of first HDR-BT (p = 0.033, and PSA on date of first follow-up after one year (p = 0.025 have statistical significance on a higher risk to get a local recurrence during follow-up. HDR-BT in combination with additional EBRT in the presented design for high-risk PCa results in high biochemical control rates with minimal side-effects. PSA is a negative predictive biomarker for local recurrence during follow-up. A longer follow-up is needed to assess long-term outcome and toxicities.

  16. Braquiterapia intersticial de alta tasa de rescate en cáncer cabeza cuello previamente radiado High-dose-rate (HDR brachytherapy in previously irradiated recurrent head and neck cancer

    Directory of Open Access Journals (Sweden)

    Lucía Gutiérrez-Bayard

    2011-09-01

    Full Text Available A pesar de los avances en el tratamiento de cáncer de cabeza y cuello (CCC, el 15-50% de los pacientes presentan recurrencia locorregional. Para los pacientes que presentan enfermedad localmente recurrente o un segundo tumor primario en un campo previamente irradiado, las opciones terapéuticas de rescate son limitadas, siendo la resección quirúrgica con intención curativa la opción de elección para los pacientes con enfermedad limitada. Reirradiación con o sin la adición de quimioterapia puede ser una buena opción, obteniendo en pacientes seleccionados supervivencia a largo plazo. La braquiterapia de alta tasa de dosis (HDRBT puede jugar un papel importante en el tratamiento de rescate en tumores de cabeza y cuello recurrentes. Presentamos un paciente de 56 años diagnosticado de cáncer de lengua sometido a cirugía y radioterapia externa adyuvante, y recurrencia metastásica ganglionar cervical contralateral a los 18 meses. Recibió tratamiento multidisciplinar con quimioterapia, cirugía y braquiterapia intersticial.Despite advances in the treatment of head and neck cancer (HNC, 15-50% of patients present locoregional disease recurrence. The therapeutic options are limited for patients who present locally recurrent disease or a second primary tumor in a previously irradiated field. Surgical salvage with curative intent is the preferred option for patients with limited-volume disease. Re-irradiation with or without the addition of chemotherapy may hold promise for long-term survival for selected patients. High-dose-rate (HDR brachytherapy can play an important role in the salvage treatment of previously irradiated recurrent head and neck cancer. The case reported was a 56-year old man diagnosed of tongue cancer who presented recurrent metastatic contralateral cervical node 1.5 years after radical treatment with surgery and adjuvant external radiotherapy. He received multidisciplinary treatment with chemotherapy, surgery and HDR

  17. The relationship between the biochemical control outcomes and the quality of planning of high-dose rate brachytherapy as a boost to external beam radiotherapy for locally and locally advanced prostate cancer using the RTOG-ASTRO Phoenix definition

    Directory of Open Access Journals (Sweden)

    Antonio Cassio Assis Pellizzon, João Salvajoli, Paulo Novaes, Maria Maia, Ricardo Fogaroli, Doglas Gides, Rodrigues Horriot

    2008-01-01

    Full Text Available Purpose: To evaluated prognostic factors and impact of the quality of planning of high dose rate brachytherapy (HDR-BT for patients with local or locally advanced prostate cancer treated with external beam radiotherapy (EBRT and HDR-BT. Methods and Materials: Between 1997 and 2005, 209 patients with biopsy proven prostate adenocarcinoma were treated with localized EBRT and HDR-BT at the Department of Radiation-Oncology, Hospital A. C. Camargo, Sao Paulo, Brazil. Patient's age, Gleason score (GS, clinical stage (CS, initial PSA (iPSA, risk group for biochemical failure (GR, doses of EBRT and HDR-BT, use of three-dimensional planning for HDR-BT (3DHDR and the Biological Effective Dose (BED were evaluated as prognostic factors for biochemical control (bC. Results: Median age and median follow-up time were 68 and 5.3 years, respectively. Median EBRT and HDR-BT doses were 45 Gy and 20 Gy. The crude bC at 3.3 year was 94.2%. For the Low, intermediate and high risk patients the bC rates at 3.3 years were 91.5%, 90.2% and 88.5%, respectively. Overall survival (OS and disease specific survival rates at 3.3 years were 97.8% and 98.4%, respectively. On univariate analysis the prognostic factors related bC were GR (p= 0.040, GS ≤ 6 (p= 0.002, total dose of HDR-BT ≥ 20 Gy (p< 0.001, 3DHDR (p< 0.001, BED-HDR ≥ 99 Gy1.5 (p<0.001 and BED-TT ≥ 185 (p<0.001. On multivariate analysis the statistical significant predictive factors related to bC were RG (p< 0.001, HDR-BT ≥ 20 Gy (p=0.008 and 3DHDR (p<0.001. Conclusions: we observed that the bC rates correlates with the generally accepted risk factors described in the literature. Dose escalation, evaluated through the BED, and the quality of planning of HDR-BT are also important predictive factors when treating prostate cancer.

  18. Dosimetric Considerations to Determine the Optimal Technique for Localized Prostate Cancer Among External Photon, Proton, or Carbon-Ion Therapy and High-Dose-Rate or Low-Dose-Rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Georg, Dietmar, E-mail: Dietmar.Georg@akhwien.at [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Hopfgartner, Johannes [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Gòra, Joanna [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Kuess, Peter [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Kragl, Gabriele [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Berger, Daniel [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Hegazy, Neamat [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Goldner, Gregor; Georg, Petra [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria)

    2014-03-01

    Purpose: To assess the dosimetric differences among volumetric modulated arc therapy (VMAT), scanned proton therapy (intensity-modulated proton therapy, IMPT), scanned carbon-ion therapy (intensity-modulated carbon-ion therapy, IMIT), and low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy (BT) treatment of localized prostate cancer. Methods and Materials: Ten patients were considered for this planning study. For external beam radiation therapy (EBRT), planning target volume was created by adding a margin of 5 mm (lateral/anterior–posterior) and 8 mm (superior–inferior) to the clinical target volume. Bladder wall (BW), rectal wall (RW), femoral heads, urethra, and pelvic tissue were considered as organs at risk. For VMAT and IMPT, 78 Gy(relative biological effectiveness, RBE)/2 Gy were prescribed. The IMIT was based on 66 Gy(RBE)/20 fractions. The clinical target volume planning aims for HDR-BT ({sup 192}Ir) and LDR-BT ({sup 125}I) were D{sub 90%} ≥34 Gy in 8.5 Gy per fraction and D{sub 90%} ≥145 Gy. Both physical and RBE-weighted dose distributions for protons and carbon-ions were converted to dose distributions based on 2-Gy(IsoE) fractions. From these dose distributions various dose and dose–volume parameters were extracted. Results: Rectal wall exposure 30-70 Gy(IsoE) was reduced for IMIT, LDR-BT, and HDR-BT when compared with VMAT and IMPT. The high-dose region of the BW dose–volume histogram above 50 Gy(IsoE) of IMPT resembled the VMAT shape, whereas all other techniques showed a significantly lower high-dose region. For all 3 EBRT techniques similar urethra D{sub mean} around 74 Gy(IsoE) were obtained. The LDR-BT results were approximately 30 Gy(IsoE) higher, HDR-BT 10 Gy(IsoE) lower. Normal tissue and femoral head sparing was best with BT. Conclusion: Despite the different EBRT prescription and fractionation schemes, the high-dose regions of BW and RW expressed in Gy(IsoE) were on the same order of magnitude. Brachytherapy techniques

  19. Cervical Gross Tumor Volume Dose Predicts Local Control Using Magnetic Resonance Imaging/Diffusion-Weighted Imaging—Guided High-Dose-Rate and Positron Emission Tomography/Computed Tomography—Guided Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Dyk, Pawel; Jiang, Naomi; Sun, Baozhou; DeWees, Todd A. [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Fowler, Kathryn J.; Narra, Vamsi [Department of Diagnostic Radiology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri (United States); Garcia-Ramirez, Jose L.; Schwarz, Julie K. [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Grigsby, Perry W., E-mail: pgrigsby@wustl.edu [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Division of Nuclear Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri (United States); Division of Gynecologic Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri (United States); Alvin J. Siteman Cancer Center, Washington University School of Medicine, St Louis, Missouri (United States)

    2014-11-15

    Purpose: Magnetic resonance imaging/diffusion weighted-imaging (MRI/DWI)-guided high-dose-rate (HDR) brachytherapy and {sup 18}F-fluorodeoxyglucose (FDG) — positron emission tomography/computed tomography (PET/CT)-guided intensity modulated radiation therapy (IMRT) for the definitive treatment of cervical cancer is a novel treatment technique. The purpose of this study was to report our analysis of dose-volume parameters predicting gross tumor volume (GTV) control. Methods and Materials: We analyzed the records of 134 patients with International Federation of Gynecology and Obstetrics stages IB1-IVB cervical cancer treated with combined MRI-guided HDR and IMRT from July 2009 to July 2011. IMRT was targeted to the metabolic tumor volume and lymph nodes by use of FDG-PET/CT simulation. The GTV for each HDR fraction was delineated by use of T2-weighted or apparent diffusion coefficient maps from diffusion-weighted sequences. The D100, D90, and Dmean delivered to the GTV from HDR and IMRT were summed to EQD2. Results: One hundred twenty-five patients received all irradiation treatment as planned, and 9 did not complete treatment. All 134 patients are included in this analysis. Treatment failure in the cervix occurred in 24 patients (18.0%). Patients with cervix failures had a lower D100, D90, and Dmean than those who did not experience failure in the cervix. The respective doses to the GTV were 41, 58, and 136 Gy for failures compared with 67, 99, and 236 Gy for those who did not experience failure (P<.001). Probit analysis estimated the minimum D100, D90, and Dmean doses required for ≥90% local control to be 69, 98, and 260 Gy (P<.001). Conclusions: Total dose delivered to the GTV from combined MRI-guided HDR and PET/CT-guided IMRT is highly correlated with local tumor control. The findings can be directly applied in the clinic for dose adaptation to maximize local control.

  20. Control strategies for afterload reduction with an artificial vasculature device.

    Science.gov (United States)

    Giridharan, Guruprasad A; Cheng, Rolando Chip; Glower, Jacob S; Ewert, Daniel L; Sobieski, Michael A; Slaughter, Mark S; Koenig, Steven C

    2012-01-01

    Ventricular assist devices (VADs) have been used successfully as a bridge to transplant in heart failure patients by unloading ventricular volume and restoring the circulation. An artificial vasculature device (AVD) is being developed that may better facilitate myocardial recovery than VAD by controlling the afterload experienced by the native heart and controlling the pulsatile energy entering into the arterial system from the device, potentially reconditioning the arterial system properties. The AVD is a valveless, 80 ml blood chamber with a servo-controlled pusher plate connected to the ascending aorta by a vascular graft. Control algorithms for the AVD were developed to maintain any user-defined systemic input impedance (IM) including resistance, elastance, and inertial components. Computer simulation and mock circulation models of the cardiovascular system were used to test the efficacy of two control strategies for the AVD: 1) average impedance position control (AIPC)-to maintain an average value of resistance during left ventricular (LV) systole and 2) instantaneous impedance force feedback (IIFF) and position control (IIPC)-to maintain a desired value or profile of resistance and compliance. Computer simulations and mock loop tests were performed to predict resulting cardiovascular pressures, volumes, flows, and the resistance and compliance experienced by the native LV during ejection for simulated normal, failing, and recovering LV. These results indicate that the LV volume and pressure decreased, and the LV stroke volume increased with decreasing IM, resulting in an increased ejection fraction. Although the AIPC algorithm is more stable and can tolerate higher levels of sensor errors and noise, the IIFF and IIPC control algorithms are better suited to maintain any instantaneous IM or an IM profile. The developed AVD impedance control algorithms may be implemented with current VADs to promote myocardial recovery and facilitate weaning.

  1. Clinical study of high dose rate brachytherapy on cervical carcinoma%高剂量率近距离腔内超分割放射治疗宫颈癌的临床研究

    Institute of Scientific and Technical Information of China (English)

    任锦霞; 王小虎; 赵林; 高力英; 吉宏; 刘志强; 罗莉; 杜瑞琴

    2012-01-01

    Objective To explore the possibility and biological effect in clinic by applying unconventional fractionation of intracavitary brachytherapy. Methods In vitro radiotherapy + high dose rate brachytherapy (HDR) cavity radiotherapy were applied in the treatment: the accelerator 6 MV-X lines by Simens were used in vitro illumination; around entire pelvic cavity 2 wilds central technology illuminations etc were also used; integral dose was 46-50 Gy, 23-25 fractions, for 5 weeks. When external irradiation entire pelvic cavity dosage was 30 Gy, 15 fractions the pelvic cavity central kept off the lead (4 cm×10 cm) and started to work in short-distance cavity treatment. The 192Ir high dose rate breech loading therapeutic equipment was used, without cavity internal radiation in vitro illumination at the same day. In the HDR cavity the ultra divisiongroup: point A (Ⅱb, Ⅲ) received 4 Gy perfraction, twice daily of intracavitary irradiation at point A. The intrafraction interval was more than 6 hours daily. The total dose at point A was 40 Gy in 10 fractions, 5 days, 3-4 weeks. In HDR cavity conventional division group: point A (ⅡI b, Ⅲ) received 6 Gy perfraction. The total dose at point A was 36 Gy in 6 fractions, 6 days, 6 weeks. Results By the end of radiotherapy, local control of 24 patients complete remission + partial remission was 100% and the control was 95.83% after a year. Early vagina reaction was: I degree for 10 cases, Ⅱ degree for 11 cases and Ⅲ degree for 3 cases. The reaction did not cause any break-up of treatment. Conclusion Enough fractionation including fraction number and dose perfraction are very important to improve the treatment effect and decrease the later complications of the HDR intracavitary brachytherapy for cervix carcinoma. The method is applicable because of its satisfactory early effects. Further follow-up is needed to evaluate its survival rate as well as later tissue injury.%目的 采用非常规的腔内治疗分割方式,探

  2. Estimation of Filling and Afterload Conditions by Pump Intrinsic Parameters in a Pulsatile Total Artificial Heart.

    Science.gov (United States)

    Cuenca-Navalon, Elena; Laumen, Marco; Finocchiaro, Thomas; Steinseifer, Ulrich

    2016-07-01

    A physiological control algorithm is being developed to ensure an optimal physiological interaction between the ReinHeart total artificial heart (TAH) and the circulatory system. A key factor for that is the long-term, accurate determination of the hemodynamic state of the cardiovascular system. This study presents a method to determine estimation models for predicting hemodynamic parameters (pump chamber filling and afterload) from both left and right cardiovascular circulations. The estimation models are based on linear regression models that correlate filling and afterload values with pump intrinsic parameters derived from measured values of motor current and piston position. Predictions for filling lie in average within 5% from actual values, predictions for systemic afterload (AoPmean , AoPsys ) and mean pulmonary afterload (PAPmean ) lie in average within 9% from actual values. Predictions for systolic pulmonary afterload (PAPsys ) present an average deviation of 14%. The estimation models show satisfactory prediction and confidence intervals and are thus suitable to estimate hemodynamic parameters. This method and derived estimation models are a valuable alternative to implanted sensors and are an essential step for the development of a physiological control algorithm for a fully implantable TAH.

  3. Intraluminal colonization into the seminiferous tubules in mice

    Directory of Open Access Journals (Sweden)

    Luis Guzmán-Masias

    2011-05-01

    Full Text Available Using the primordial germ cells transplant technique, we could be able preserve and multiply pluripotent cells in the receptor for a long period of time. In this work, We aim to evaluate intraluminal colonization of a cellular gonocyte suspension from 14.5 dpc fetus. Cellular suspension with PGC's were isolated from fetus male mice by two enzymatic digestion steps, and cellular suspensions were transplanted into the rete testis of the receptor animals that were previously injected with Busulfan to decrease their own spermatogenesis. In this research the intraluminal colonization was identified in 13.27%, demonstrating that transplantation of a cellular suspension from gonocytes of fetus of 14.5 dpc containing PGCs can colonize the seminiferous tubules and support the spermatogenesis.

  4. Sutureless choledochoduodenostomy with an intraluminal degradable stent in dog model

    Institute of Scientific and Technical Information of China (English)

    ZHU Ling-hua; LIANG Xiao; LIN Hui; WANG Yi-fan; ZHU Yi-ping; CAI Xiu-jun

    2011-01-01

    Background It is difficult and time-consuming for carrying out conventional hand-sewn bilioenteric anastomosis, especially for small bile duct anastomosis and laparoscopic procedure. In order to simplify it, we have developed a novel procedure of sutureless bilioenteric anastomosis with an intraluminal degradable stent. This study aimed to evaluate the feasibility and safety of this technique with cholangioduodenostomy in dog model.Methods A patent intraluminal degradable stent tube for sutureless choledochoduodenostomy in dog model was made with polylactic acid in diameter of 3 mm or 4 mm. Thirty-eight dogs were randomly divided into to a stent group (SG, n=20) and a control group (CG, n=18). Dogs in the SG underwent sutureless choledochoduodenostomy with intraluminal stent, while the CG underwent conventional choledochoduodenostomy (single layer discontinuous anastomosis with absorbable suture). Dogs of each group were divided into 4 subgroups according to time of death (1,3,6, and 12 months postoperatively) to evaluate the healing of anastomosis. Operation time, intraoperative tolerance pressure of anastomosis, rate of postoperative bile leakage, bursting pressure of anastomosis were compared between the two groups. Anastomosis tissue was observed afterwards by pathology evaluation, hydroxyproline content, serum bilirubin, liver enzyme level and magnetic resonance cholangio-pancreatography (MRCP) to assess the stricture.Results All procedures were completed successfully. The surgical time of the SG was significantly less than the CG (SG: (19.2±4.3) minutes, vs. CG: (29.2±7.1) minutes, P=0.000). One bile leakage was occurred in either group. No significant difference of intraoperative tolerance pressure of anastomosis, rate of bile leakage and postoperative bursting pressure of anastomosis, anastomotic stricture, hydroxyproline content, serum bilirubin and liver enzyme level was found between the two groups. MRCP showed no anastomosis stricture and obstruction

  5. Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE{sup Registered-Sign} radiochromic plastic

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, A. L. [Department of Physics, Faculty of Engineering and Physical Science, University of Surrey, Surrey GU2 7JP (United Kingdom); Department of Medical Physics, F-Level, Queen Alexandra Hospital, Portsmouth Hospitals NHS Trust, Portsmouth, Hampshire PO6 3LY (United Kingdom); Di Pietro, P.; Alobaidli, S.; Issa, F.; Doran, S.; Bradley, D. [Department of Physics, Faculty of Engineering and Physical Science, University of Surrey, Surrey GU2 7JP (United Kingdom); Nisbet, A. [Department of Physics, Faculty of Engineering and Physical Science, University of Surrey, Surrey GU2 7JP (United Kingdom); Department of Medical Physics, Royal Surrey County Hospital NHS Foundation Trust, Guildford, Surrey GU2 7XX (United Kingdom)

    2013-06-15

    Purpose: Dose distribution measurement in clinical high dose rate (HDR) brachytherapy is challenging, because of the high dose gradients, large dose variations, and small scale, but it is essential to verify accurate treatment planning and treatment equipment performance. The authors compare and evaluate three dosimetry systems for potential use in brachytherapy dose distribution measurement: Ge-doped optical fibers, EBT3 Gafchromic film with multichannel analysis, and the radiochromic material PRESAGE{sup Registered-Sign} with optical-CT readout. Methods: Ge-doped SiO{sub 2} fibers with 6 {mu}m active core and 5.0 mm length were sensitivity-batched and their thermoluminescent properties used via conventional heating and annealing cycles. EBT3 Gafchromic film of 30 {mu}m active thickness was calibrated in three color channels using a nominal 6 MV linear accelerator. A 48-bit transmission scanner and advanced multichannel analysis method were utilized to derive dose measurements. Samples of the solid radiochromic polymer PRESAGE{sup Registered-Sign }, 60 mm diameter and 100 mm height, were analyzed with a parallel beam optical CT scanner. Each dosimetry system was used to measure the dose as a function of radial distance from a Co-60 HDR source, with results compared to Monte Carlo TG-43 model data. Each system was then used to measure the dose distribution along one or more lines through typical clinical dose distributions for cervix brachytherapy, with results compared to treatment planning system (TPS) calculations. Purpose-designed test objects constructed of Solid Water and held within a full-scatter water tank were utilized. Results: All three dosimetry systems reproduced the general shape of the isolated source radial dose function and the TPS dose distribution. However, the dynamic range of EBT3 exceeded those of doped optical fibers and PRESAGE{sup Registered-Sign }, and the latter two suffered from unacceptable noise and artifact. For the experimental

  6. Reduction in radiation exposure to nursing personnel with the use of remote afterloading brachytherapy devices

    Energy Technology Data Exchange (ETDEWEB)

    Grigsby, P.W.; Perez, C.A.; Eichling, J.; Purdy, J.; Slessinger, E. (Mallinckrodt Institute of Radiology, St. Louis, MO (USA))

    1991-03-01

    The radiation exposure to nursing personnel from patients with brachytherapy implants on a large brachytherapy service were reviewed. Exposure to nurses, as determined by TLD monitors, indicates a 7-fold reduction in exposure after the implementation of the use of remote afterloading devices. Quarterly TLD monitor data for six quarters prior to the use of remote afterloading devices demonstrate an average projected annual dose equivalent to the nurses of 152 and 154 mrem (1.5 mSv). After the implementation of the remote afterloading devices, the quarterly TLD monitor data indicate an average dose equivalent per nurse of 23 and 19 mrem (0.2 mSv). This is an 87% reduction in exposure to nurses with the use of these devices (p less than 0.01).

  7. A multicenter study to quantify systematic variations and associated uncertainties in source positioning with commonly used HDR afterloaders and ring applicators for the treatment of cervical carcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Awunor, O., E-mail: onuora.awunor@stees.nhs.uk [The Medical Physics Department, The James Cook University Hospital, Marton Road, Middlesbrough TS4 3BW, England (United Kingdom); Berger, D. [Department of Radiotherapy, General Hospital of Vienna, Vienna A-1090 (Austria); Kirisits, C. [Department of Radiotherapy, Comprehensive Cancer Center, Medical University of Vienna, Vienna A-1090 (Austria)

    2015-08-15

    Purpose: The reconstruction of radiation source position in the treatment planning system is a key part of the applicator reconstruction process in high dose rate (HDR) brachytherapy treatment of cervical carcinomas. The steep dose gradients, of as much as 12%/mm, associated with typical cervix treatments emphasize the importance of accurate and precise determination of source positions. However, a variety of methodologies with a range in associated measurement uncertainties, of up to ±2.5 mm, are currently employed by various centers to do this. In addition, a recent pilot study by Awunor et al. [“Direct reconstruction and associated uncertainties of {sup 192}Ir source dwell positions in ring applicators using gafchromic film in the treatment planning of HDR brachytherapy cervix patients,” Phys. Med. Biol. 58, 3207–3225 (2013)] reported source positional differences of up to 2.6 mm between ring sets of the same type and geometry. This suggests a need for a comprehensive study to assess and quantify systematic source position variations between commonly used ring applicators and HDR afterloaders across multiple centers. Methods: Eighty-six rings from 20 European brachytherapy centers were audited in the form of a postal audit with each center collecting the data independently. The data were collected by setting up the rings using a bespoke jig and irradiating gafchromic films at predetermined dwell positions using four afterloader types, MicroSelectron, Flexitron, GammaMed, and MultiSource, from three manufacturers, Nucletron, Varian, and Eckert & Ziegler BEBIG. Five different ring types in six sizes (Ø25–Ø35 mm) and two angles (45° and 60°) were used. Coordinates of irradiated positions relative to the ring center were determined and collated, and source position differences quantified by ring type, size, and angle. Results: The mean expanded measurement uncertainty (k = 2) along the direction of source travel was ±1.4 mm. The standard deviation

  8. The external work-pressure time integral relationships and the afterload dependence of Frank-Starling mechanism.

    Science.gov (United States)

    Sela, Gali; Landesberg, Amir

    2009-10-01

    The mechanisms underlying the Frank-Starling Law of the heart are elusive and the prevalent notion suggests that it is afterload independent. However, isolated fiber studies reveal that the afterload determines cardiac function through cross-bridge dependent mechanisms. The study explores the roles of the afterload, in situ. The LV was exposed by left-thoracotomy in adult sheep (72.6+/-8.2 kg, n=8). Pressure transducers were inserted into the LV and aorta, a flowmeter was placed around the aortic root, and the LV volume was assessed by sonocrystals. Occluders around the aorta and the inferior vena cava enabled control of the afterload and preload. Different afterloads were imposed by partial aortic occlusions. Transient inferior vena cava occlusions (IVCOs) were preformed whenever the afterload was steady. A highly linear relationship was found between the external work (EW) and pressure time integral (PTI) (R(2)=0.98+/-0.01) during each transient IVCO (n=48). The slope of the EW-PTI relationship (WPTiR) was preload independent since, for any given afterload, the EW and PTI lay on a straight line. Interestingly, the slope of the WPTiR was afterload dependant: The slope was 33.3+/-4.1 mJ/mmHg.s at baselines and decreased by 1.0+/-0.50 mJ/mmHg.s with every 1 mmHg.min/L increase in the peripheral resistance. A unique WPTiR was obtained during both the occlusion and release phases of each IVCO, while two distinct EW-preload or PTI-preload relationships were observed. The novel WPTiR ties the Frank (pressure development) and Starling (EW production) phenomena together. The dependence of the WPTiR on the afterload highlights the adaptive control of the Frank-Starling mechanisms to changes in the afterload.

  9. A compilation of current regulations, standards and guidelines in remote afterloading brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Tortorelli, J.P.; Simion, G.P.; Kozlowski, S.D. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1994-10-01

    Over a dozen government and professional organizations in the United States and Europe have issued regulations and guidance concerning quality management in the practice of remote afterloading brachytherapy. Information from the publications of these organizations was collected and collated for this report. This report provides the brachytherapy licensee access to a broad field of quality management information in a single, topically organized document.

  10. Mechanical efficiency of stunned myocardium is modulated by increased afterload dependency

    NARCIS (Netherlands)

    D. Fan (Dongsheng); L.K. Soei (Lou Kie); L.M. Sassen; R. Krams (Rob); P.D. Verdouw (Pieter)

    1994-01-01

    textabstractOxygen consumption (MVO2) of stunned myocardium is relatively high compared to, and poorly correlated with, systolic contractile function. The aim of this study was to investigate whether an increased afterload dependency, induced by the decreased contractility of the stunned myocardium,

  11. Divertículo intraluminal do duodeno: relato de caso

    OpenAIRE

    Furtado Evaldo; Machado Beatriz Ferreira Furtado

    2003-01-01

    Os autores apresentam um caso de divertículo intraluminal do duodeno em uma paciente de 44 anos de idade, com sintomas escassos e incaracterísticos. O diagnóstico radiológico foi confirmado à cirurgia e houve controle pós-operatório. A anomalia, uma forma rara de duplicação, com diagnóstico radiológico unicamente pelo exame baritado convencional pré-operatório, consiste de uma estrutura em "fundo de saco", revestida de ambos os lados por mucosa normal, projetando-se na luz do duodeno. Após a ...

  12. Proposal of a postal system for Ir-192 sources calibration used in high dose rate brachytherapy with LiF:Mn:Ti thermoluminescent dosemeters; Proposta de um sistema postal para a calibracao de fontes de {sup 192} Ir, utilizadas em braquiterapia de alta taxa de dose, com dosimetros termoluminescentes de LiF: Mn: Ti

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, W.S.; Borges, J.C.; Almeida, C.E.V. [Instituto de Radioprotecao e Dosimetria. CNEN Caixa Postal 37750, 22780-160, Rio de Janeiro (Brazil)

    1998-12-31

    A proposal in order to improve the brachytherapy quality control and to allow postal intercomparison of Ir-192 sources used in high dose rate brachytherapy has been presented. The LiF: Mn: Ti (TLD 100) detector has been selected for such purpose. The experimental array and the TLDs irradiation and calibration techniques, at the treatment units, have been specified in the light of more recent methodology of Ir-192 calibration sources. (Author)

  13. Intraluminal bubble dynamics induced by lithotripsy shock wave

    Science.gov (United States)

    Song, Jie; Bai, Jiaming; Zhou, Yufeng

    2016-12-01

    Extracorporeal shock wave lithotripsy (ESWL) has been the first option in the treatment of calculi in the upper urinary tract since its introduction. ESWL-induced renal injury is also found after treatment and is assumed to associate with intraluminal bubble dynamics. To further understand the interaction of bubble expansion and collapse with the vessel wall, the finite element method (FEM) was used to simulate intraluminal bubble dynamics and calculate the distribution of stress in the vessel wall and surrounding soft tissue during cavitation. The effects of peak pressure, vessel size, and stiffness of soft tissue were investigated. Significant dilation on the vessel wall occurs after contacting with rapid and large bubble expansion, and then vessel deformation propagates in the axial direction. During bubble collapse, large shear stress is found to be applied to the vessel wall at a clinical lithotripter setting (i.e. 40 MPa peak pressure), which may be the mechanism of ESWL-induced vessel rupture. The decrease of vessel size and viscosity of soft tissue would enhance vessel deformation and, consequently, increase the generated shear stress and normal stresses. Meanwhile, a significantly asymmetric bubble boundary is also found due to faster axial bubble expansion and shrinkage than in radial direction, and deformation of the vessel wall may result in the formation of microjets in the axial direction. Therefore, this numerical work would illustrate the mechanism of ESWL-induced tissue injury in order to develop appropriate counteractive strategies for reduced adverse effects.

  14. Use of intraluminal protection in colonic anastomosis in dogs Uso de protetor intraluminal em anastomose colônica em cães

    Directory of Open Access Journals (Sweden)

    André Lacerda de Abreu Oliveira

    2007-02-01

    Full Text Available PURPOSE: To test the use of intraluminal protection in colonic anastomosis without intestinal cleansing. The intraluminal liner was fashioned from porcine submucosa preserved in glycerin and then fixed 10 cm anteriorly to the anastomotic site. This technique was compared with the one used in termino-terminal colonic anastomosis without intraluminal protection. METHODS: Twenty-eight dogs were divided into two groups of fourteen animals each. Clinical and histopathological tests were performed on the fourth and twenty-first postoperative days. RESULTS: The morbidity and mortality rates were higher in animals that did not receive the intraluminal liner. Histopathological examinations in animals in which the intraluminal liner was used showed better healing, characterized by milder inflammation and increased amount of collagen. CONCLUSION: It can be concluded that the use of intraluminal protection decreases complication rates in colonic anastomosis and promotes better healing.OBJETIVO: Testar o uso da proteção intraluminal na anastomose colônica sem preparo intestinal. O protetor intraluminal usado foi confeccionado a partir da submucosa de suíno conservada em glicerina, e fixado a 10 cm cranialmente ao sítio anastomótico. Essa técnica foi comparada com a técnica de anastomose colônica término-terminal sem uso do protetor intraluminal. MÉTODOS: Foram utilizados 28 cães divididos em dois grupos de 14 animais cada. A avaliação foi através de exames clínicos e histopatológicos. A avaliação anatomo-patológica foi realizada no quarto e vigésimo primeiro dias de pós-operatório. RESULTADOS: Um maior número de casos de morbi-mortalidade foi observado nos animais operados sem o protetor intraluminal. O exame histopatológico dos animais nos quais foram usados os protetores intraluminais mostrou melhor cicatrização, caracterizada por processo inflamatório mais discreto e maior quantidade de colágeno. CONCLUSÃO: O uso do protetor

  15. Uncertainty in delivered dose resulting from the distribution of source activities in a Selectron LDR afterloader

    Energy Technology Data Exchange (ETDEWEB)

    Ho, A.K.; Castiglione, Robert; Podgorsak, M.B.; Sibata, C.H.; Shin, K.H. (Roswell Park Cancer Inst., Buffalo, NY (United States). Dept. of Radiation Medicine)

    1994-11-01

    The uncertainty in the delivered dose resulting from the distribution of [sup 137]Cs source activity in a clinical Selectron LDR unit has been studied. A comparison is made of the dose delivered to a point 'A' in an implant with sources of equal activity to the actual dose delivered in the same implant with source activities randomly chosen from the population in the afterloader. (author).

  16. Contractility-afterload mismatch in patients with protein-losing enteropathy after the Fontan operation.

    Science.gov (United States)

    Ozawa, Hideto; Ueno, Takayoshi; Iwai, Shigemitsu; Kawata, Hiroaki; Nishigaki, Kyouichi; Kishimoto, Hidefumi; Sawa, Yoshiki

    2014-10-01

    This study aimed to clarify the relationship between onset of protein-losing enteropathy (PLE) and Fontan circulation, with special reference to the development of contractility-afterload mismatch. The PLE group comprised 9 patients who experienced PLE after undergoing the Fontan operation, and the control group consisted of 32 patients had did not experienced PLE more than 10 years after the Fontan operation. The study compared the pre- and postoperative values of arterial elastance (Ea), end-systolic elastance (Ees), and contractility-afterload mismatch (Ea/Ees). Furthermore, the variations in the values were examined during the preoperative, postoperative, and midterm postoperative periods in seven PLE patients who underwent cardiac catheterization at the onset of PLE and during the pre- and postintervention periods in three PLE patients who underwent surgical intervention to improve the Fontan circulation after the onset of PLE. Comparison of the values obtained before and after Fontan operations showed that the Ea values increased significantly in the PLE group. However, the pre- and postoperative Ees values did not differ in the two groups. During the postoperative period, Ea/Ees increased significantly, and the Ea and Ea/Ees values increased continuously until the onset of PLE in the PLE group. In the patients who underwent surgical intervention to improve the Fontan circulation after the onset of PLE, the Ea/Ees decreased significantly, and the serum albumin levels improved after the intervention. Contractility-afterload mismatch, mainly caused by the increase in the afterload of the systemic ventricle, may have an important role in the development of PLE after the Fontan operation.

  17. [Improvement of gynecologic radium therapy through the afterloading method using cesium 137].

    Science.gov (United States)

    Fournier, D V; Senf, W; Kuttig, H; Kubli, F

    1976-03-01

    For all centers performing gynecological contact irradiation the use of afterloading techniques is urgently required, since they eliminate any radiation exposure to the personnel. The radio-therapist may position and control the empty applicators still free from radiation withoug haste. This procedure diminishes the occurrence of overdosages and underdosages. The care for the patients is possible without radiation exposure, and the morbidity of contact therapy can be reduced by occasional mobilization of the patient, the applicator without sources remaining at its place. The fully automatic apparatus "Curietron" using cesium-137 sources (0.662 MeV gamma emission, half-life period 26.6 years) with an equivalent source activity (factor 2.6) yields the dose distribution demanded in the gynecologic field which in practice is identical to that of Ra-226 (medium gamma emission 1 MeV, half-life period 1620 years). With similar dose distribution, a biological and therapeutical effect alike to Ra-226 may be expected from Cs-137. In comparison with Ra-226, the following advantages of Cs-137 may be mentioned: Lower half-value thickness of 5.5 mm lead (low expenses for radioprotection), less danger with handling (no emanation of radioactive gases), and lower contamination risks in case of breaking. The measured dose distributions at equivalent source activity and similar geometry of the applicators revealed the possibility with regard of all techniques of gynecologic irradiation utilized in our field of arriving at similar relative and absolute dose distributions by means of the Cs-137 afterloading technique. Whilst short-term afterloading irradiation with highly active sources, their radiobiological effectiveness being not yet ascertained, has to be tested at appropriate scientific centers, it is necessary to demand afterloading techniques with dosages and duration of irradiations approved over decades for all centers of gynecological contact therapy because of radiation

  18. Human factors evaluation of remote afterloading brachytherapy: Human error and critical tasks in remote afterloading brachytherapy and approaches for improved system performance. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Callan, J.R.; Kelly, R.T.; Quinn, M.L. [Pacific Science and Engineering Group, San Diego, CA (United States)] [and others

    1995-05-01

    Remote Afterloading Brachytherapy (RAB) is a medical process used in the treatment of cancer. RAB uses a computer-controlled device to remotely insert and remove radioactive sources close to a target (or tumor) in the body. Some RAB problems affecting the radiation dose to the patient have been reported and attributed to human error. To determine the root cause of human error in the RAB system, a human factors team visited 23 RAB treatment sites in the US The team observed RAB treatment planning and delivery, interviewed RAB personnel, and performed walk-throughs, during which staff demonstrated the procedures and practices used in performing RAB tasks. Factors leading to human error in the RAB system were identified. The impact of those factors on the performance of RAB was then evaluated and prioritized in terms of safety significance. Finally, the project identified and evaluated alternative approaches for resolving the safety significant problems related to human error.

  19. Angioplasty of symptomatic high-grade internal carotid artery stenosis with intraluminal thrombus: therapeutic approach

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, A.; Mayol, A. [Seccion de Neurorradiologia Intervencionista, Servicio de Radiologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Gil-Peralta, A.; Gonzalez-Marcos, J.R. [Servicio de Neurologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Boza, F. [Servicio de Neurofisiologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Ruano, J. [Unidad de Cuidados Intensivos, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain)

    2004-04-01

    Intraluminal thrombus in the internal carotid artery (ICA) is usually found in patients with severe atheromatous stenosis. Having reviewed 300 carotid angioplasties for symptomatic >70% ICA stenosis, we found three patients (1%) with intraluminal thrombus. Conservative treatment with anticoagulants and double antiplatelet coverage can result in lysis of the thrombus without severe risks. Percutaneous transluminal angioplasty and stenting, preferably with distal protection, can be an excellent alternative to carotid endarterectomy. (orig.)

  20. Intracavitary afterloading boost in anal canal carcinoma. Results, function and quality of life

    Energy Technology Data Exchange (ETDEWEB)

    Vordermark, D.; Flentje, M.; Koelbl, O. [Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Strahlentherapie; Sailer, M. [Wuerzburg Univ. (Germany). Klinik fuer Chirurgie

    2001-05-01

    Background: First clinical data on a new intracavitary afterloading boost method for anal canal carcinoma is reported. Patients and Methods: 20 consecutive patients (T1 5%, T2 70%, T3 20%, T4 5%; N0 75%, N1 10%, N2 15%; all M0) treated with external beam pelvic radiotherapy (median dose 56 Gy, range 46-64 Gy), simultaneous 5-FU and mitomycin (in 75%) and an intracavitary afterloading boost (one or two fractions of 5 Gy at 5 mm depth) were analyzed after a mean {+-}SD follow-up for living patients of 4.4{+-}2.1 years. Quality of life (QoL) and anorectal manometry parameters were assessed in ten colostomy-free survivors. Results: Overall, recurrence-free and colostomy-free survival at 5 years were 84%, 79% and 69%, respectively. No death was tumorrelated. The only local failure was successfully salvaged by local excision. All three colostomies were performed for toxicity. Resting pressure and maximum squeeze pressure of the anal sphincter were reduced by 51% and 71%, as compared with control subjects, but quality of life was similar compared to healthy volunteers. Conclusion: the described regimen is highly effective but associated with increased toxicity. (orig.) [German] Hintergrund: Erste klinische Ergebnisse einer neuen Methode zur intrakavitaeren Afterloading-Boost-Bestrahlung des Analkanalkarzinoms werden vorgestellt. Patienten und Methoden: 20 in Folge behandelte Patienten (T1 5%, T2 70%, T3 20%, T4 5%, N0 75%, N1 10%, N2 15 %; alle M0) erhielten eine perkutane Bestrahlung (mediane Dosis 56 Gy, 46-64 Gy), simultan 5-FU und Mitomycin (75%) und einen intrakavitaeren Afterloading-Boost (eine oder zwei Fraktionen mit je 5 Gy in 5 mm Tiefe). Der mittlere Nachbeobachtungszeitraum lebender Patienten betrug 4,4{+-}2,1 Jahre. Zehn kolostomiefrei Ueberlebende wurden bezueglich Lebensqualitaet und anorektaler Manometriewerte untersucht. Ergebnisse: Gesamtueberleben, rezidivfreies und kolostomiefreies Ueberleben nach 5 Jahren betrugen 84%, 79% und 69%. Kein Todesfall war

  1. Imaging method for monitoring delivery of high dose rate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Weisenberger, Andrew G; Majewski, Stanislaw

    2012-10-23

    A method for in-situ monitoring both the balloon/cavity and the radioactive source in brachytherapy treatment utilizing using at least one pair of miniature gamma cameras to acquire separate images of: 1) the radioactive source as it is moved in the tumor volume during brachytherapy; and 2) a relatively low intensity radiation source produced by either an injected radiopharmaceutical rendering cancerous tissue visible or from a radioactive solution filling a balloon surgically implanted into the cavity formed by the surgical resection of a tumor.

  2. Human factors evaluation of remote afterloading brachytherapy. Volume 2, Function and task analysis

    Energy Technology Data Exchange (ETDEWEB)

    Callan, J.R.; Gwynne, J.W. III; Kelly, T.T.; Muckler, F.A. [Pacific Science and Engineering Group, San Diego, CA (United States); Saunders, W.M.; Lepage, R.P.; Chin, E. [University of California San Diego Medical Center, CA (United States). Div. of Radiation Oncology; Schoenfeld, I.; Serig, D.I. [Nuclear Regulatory Commission, Washington, DC (United States). Div. of Systems Technology

    1995-05-01

    A human factors project on the use of nuclear by-product material to treat cancer using remotely operated afterloaders was undertaken by the Nuclear Regulatory Commission. The purpose of the project was to identify factors that contribute to human error in the system for remote afterloading brachytherapy (RAB). This report documents the findings from the first phase of the project, which involved an extensive function and task analysis of RAB. This analysis identified the functions and tasks in RAB, made preliminary estimates of the likelihood of human error in each task, and determined the skills needed to perform each RAB task. The findings of the function and task analysis served as the foundation for the remainder of the project, which evaluated four major aspects of the RAB system linked to human error: human-system interfaces; procedures and practices; training and qualifications of RAB staff; and organizational practices and policies. At its completion, the project identified and prioritized areas for recommended NRC and industry attention based on all of the evaluations and analyses.

  3. A combination of high dose rate (10X FFF/2400 MU/min/10 MV X-rays) and total low dose (0.5 Gy) induces a higher rate of apoptosis in melanoma cells in vitro and superior preservation of normal melanocytes.

    Science.gov (United States)

    Sarojini, Sreeja; Pecora, Andrew; Milinovikj, Natasha; Barbiere, Joseph; Gupta, Saakshi; Hussain, Zeenathual M; Tuna, Mehmet; Jiang, Jennifer; Adrianzen, Laura; Jun, Jaewook; Catello, Laurice; Sanchez, Diana; Agarwal, Neha; Jeong, Stephanie; Jin, Youngjin; Remache, Yvonne; Goy, Andre; Ndlovu, Alois; Ingenito, Anthony; Suh, K Stephen

    2015-10-01

    The aim of this study was to determine the apoptotic effects, toxicity, and radiosensitization of total low dose irradiation delivered at a high dose rate in vitro to melanoma cells, normal human epidermal melanocytes (HEM), or normal human dermal fibroblasts (HDF) and to study the effect of mitochondrial inhibition in combination with radiation to enhance apoptosis in melanoma cells. Cells irradiated using 10X flattening filter-free (FFF) 10 MV X-rays at a dose rate of 400 or 2400 MU/min and a total dose of 0.25-8 Gy were analyzed by cell/colony counting, MitoTracker, MTT, and DNA-damage assays, as well as by quantitative real-time reverse transcriptase PCR in the presence or absence of mitochondrial respiration inhibitors. A dose rate of 2400 MU/min killed on average five-fold more melanoma cells than a dose rate 400 MU/min at a total dose of 0.5 Gy and preserved 80% survival of HEM and 90% survival of HDF. Increased apoptosis at the 2400 MU/min dose rate is mediated by greater DNA damage, reduced cell proliferation, upregulation of apoptotic genes, and downregulation of cell cycle genes. HEM and HDF were relatively unharmed at 2400 MU/min. Radiation induced upregulation of mitochondrial respiration in both normal and cancer cells, and blocking the respiration with inhibitors enhanced apoptosis only in melanoma cells. A high dose rate with a low total dose (2400 MU/min, 0.5 Gy/10X FFF 10 MV X-rays) enhances radiosensitivity of melanoma cells while reducing radiotoxicity toward HEM and HDF. Selective cytotoxicity of melanoma cells is increased by blocking mitochondrial respiration.

  4. Results of Castro Bernardes intraluminal ring in surgery for ascending aortic aneurysms and dissections

    Directory of Open Access Journals (Sweden)

    Fernando Rotatori Novaes

    2013-06-01

    Full Text Available OBJECTIVE: To demonstrate surgical results using Castro Bernardes intraluminal ring in ascending aorta surgery, instead of conventional suture. METHODS: 95 patients underwent ascending aorta surgery from December 2008 to April 2011 at Madre Tereza Hospital (Belo Horizonte, MG, Brazil, using Castro Bernardes intraluminal ring instead of conventional suture of the aorta. RESULTS: Ninety five patients underwent ascending aorta surgery with Castro-Bernardes intraluminal ring. Thirty patients presented acute dissection and 65 aneurism. Overall postoperative mortality was 15.78% (15/95. Nine patients in 15 (60% died due to acute type A dissection. For acute type A dissection, mortality was 30% and for aneurism mortality was 9.23%. The intraluminal ring was inserted in distal position in 89 patients and in proximal and distal position in 6 patients. Mortality was related to Bentall & De Bono or Cabrol associated techniques. Average extracorporeal circulation time was 57.4 minutes and average aortic cross-clamping time was 37 minutes. CONCLUSION: The use of Castro Bernardes intraluminal ring in ascending aortic surgery avoiding conventional suture reduces extracorporeal circulation time and aortic cross-clamping time, improving surgical results. This approach simplifies ascending aortic surgery whether the disease is type A dissection or aneurysm, and may be considered a good alternative technique.

  5. 10 CFR 35.604 - Surveys of patients and human research subjects treated with a remote afterloader unit.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Surveys of patients and human research subjects treated... Stereotactic Radiosurgery Units § 35.604 Surveys of patients and human research subjects treated with a remote... shall survey the patient or the human research subject and the remote afterloader unit with a...

  6. Dual Endothelin Receptor Blockade Abrogates Right Ventricular Remodeling and Biventricular Fibrosis in Isolated Elevated Right Ventricular Afterload.

    Directory of Open Access Journals (Sweden)

    Eva Amalie Nielsen

    Full Text Available Pulmonary arterial hypertension is usually fatal due to right ventricular failure and is frequently associated with co-existing left ventricular dysfunction. Endothelin-1 is a powerful pro-fibrotic mediator and vasoconstrictor that is elevated in pulmonary arterial hypertension. Endothelin receptor blockers are commonly used as pulmonary vasodilators, however their effect on biventricular injury, remodeling and function, despite elevated isolated right ventricular afterload is unknown.Elevated right ventricular afterload was induced by progressive pulmonary artery banding. Seven rabbits underwent pulmonary artery banding without macitentan; 13 received pulmonary artery banding + macitentan; and 5 did not undergo inflation of the pulmonary artery band (sham-operated controls.Right and left ventricular collagen content was increased with pulmonary artery banding compared to sham-operated controls and ameliorated by macitentan. Right ventricular fibrosis signaling (connective tissue growth factor and endothelin-1 protein levels; extra-cellular matrix remodeling (matrix-metalloproteinases 2 and 9, apoptosis and apoptosis-related peptides (caspases 3 and 8 were increased with pulmonary artery banding compared with sham-operated controls and decreased with macitentan.Isolated right ventricular afterload causes biventricular fibrosis, right ventricular apoptosis and extra cellular matrix remodeling, mediated by up-regulation of endothelin-1 and connective tissue growth factor signaling. These pathological changes are ameliorated by dual endothelin receptor blockade despite persistent elevated right ventricular afterload.

  7. Calculation of muscle maximal shortening velocity by extrapolation of the force-velocity relationship: afterloaded versus isotonic release contractions.

    Science.gov (United States)

    Bullimore, Sharon R; Saunders, Travis J; Herzog, Walter; MacIntosh, Brian R

    2010-10-01

    The maximal shortening velocity of a muscle (V(max)) provides a link between its macroscopic properties and the underlying biochemical reactions and is altered in some diseases. Two methods that are widely used for determining V(max) are afterloaded and isotonic release contractions. To determine whether these two methods give equivalent results, we calculated V(max) in 9 intact single fibres from the lumbrical muscles of the frog Xenopus laevis (9.5-15.5 °C, stimulation frequency 35-70 Hz). The data were modelled using a 3-state cross-bridge model in which the states were inactive, detached, and attached. Afterloaded contractions gave lower predictions of Vmax than did isotonic release contractions in all 9 fibres (3.20 ± 0.84 versus 4.11 ± 1.08 lengths per second, respectively; means ± SD, p = 0.001) and underestimated unloaded shortening velocity measured with the slack test by an average of 29% (p = 0.001, n = 6). Excellent model predictions could be obtained by assuming that activation is inhibited by shortening. We conclude that under the experimental conditions used in this study, afterloaded and isotonic release contractions do not give equivalent results. When a change in the V(max) measured with afterloaded contractions is observed in diseased muscle, it is important to consider that this may reflect differences in either activation kinetics or cross-bridge cycling rates.

  8. The rate of force generation by the myocardium is not influenced by afterload

    Directory of Open Access Journals (Sweden)

    Fioretto J.R.

    1997-01-01

    Full Text Available The influence of afterload on the rate of force generation by the myocardium was investigated using two types of preparations: the in situ dog heart (dP/dt and isolated papillary muscle of rats (dT/dt. Thirteen anesthetized, mechanically ventilated and thoracotomized dogs were submitted to pharmacological autonomic blockade (3.0 mg/kg oxprenolol plus 0.5 mg/kg atropine. A reservoir connected to the left atrium permitted the control of left ventricular end-diastolic pressure (LVEDP. A mechanical constriction of the descending thoracic aorta allowed to increase the systolic pressure in two steps of 20 mmHg (conditions H1 and H2 above control values (condition C. After arterial pressure elevations (systolic pressure C: 119 ± 8.1; H1: 142 ± 7.9; H2 166 ± 7.7 mmHg; P<0.01, there were no significant differences in heart rate (C: 125 ± 13.9; H1: 125 ± 13.5; H2: 123 ± 14.1 bpm; P>0.05 or LVEDP (C: 6.2 ± 2.48; H1: 6.3 ± 2.43; H2: 6.1 ± 2.51 mmHg; P>0.05. The values of dP/dt did not change after each elevation of arterial pressure (C: 3,068 ± 1,057; H1: 3,112 ± 996; H2: 3,086 ± 980 mmHg/s; P>0.05. In isolated rat papillary muscle, an afterload corresponding to 50% and 75% of the maximal developed tension did not alter the values of the maximum rate of tension development (100%: 78 ± 13; 75%: 80 ± 13; 50%: 79 ± 11 g mm-2 s-1, P>0.05. The results show that the rise in afterload per se does not cause changes in dP/dt or dT/dt

  9. A pig model of acute right ventricular afterload increase by hypoxic pulmonary vasoconstriction.

    Science.gov (United States)

    Knai, Kathrine; Skjaervold, Nils Kristian

    2017-01-03

    The aim of this study was to construct a non-invasive model for acute right ventricular afterload increase by hypoxic pulmonary vasoconstriction. Intact animal models are vital to improving our understanding of the pathophysiology of acute right ventricular failure. Acute right ventricular failure is caused by increased afterload of the right ventricle by chronic or acute pulmonary hypertension combined with regionally or globally reduced right ventricular contractile capacity. Previous models are hampered by their invasiveness; this is unfortunate as the pulmonary circulation is a low-pressure system that needs to be studied in closed chest animals. Hypoxic pulmonary vasoconstriction is a mechanism that causes vasoconstriction in alveolar vessels in response to alveolar hypoxia. In this study we explored the use of hypoxic pulmonary vasoconstriction as a means to increase the pressure load on the right ventricle. Pulmonary hypertension was induced by lowering the FiO2 to levels below the physiological range in eight anesthetized and mechanically ventilated pigs. The pigs were monitored with blood pressure measurements and blood gases. The mean pulmonary artery pressures (mPAP) of the animals increased from 18.3 (4.2) to 28.4 (4.6) mmHg and the pulmonary vascular resistance (PVR) from 254 (76) dyns/cm(5) to 504 (191) dyns/cm(5), with a lowering of FiO2 from 0.30 to 0.15 (0.024). The animals' individual baseline mPAPs varied substantially as did their response to hypoxia. The reduced FiO2 level yielded an overall lowering in oxygen offer, but the global oxygen consumption was unaltered. We showed in this study that the mPAP and the PVR could be raised by approximately 100% in the study animals by lowering the FiO2 from 0.30 to 0.15 (0.024). We therefore present a novel method for minimally invasive (closed chest) right ventricular afterload manipulations intended for future studies of acute right ventricular failure. The method should in theory be reversible

  10. THYROID HORMONE REVERSES AGING-INDUCED MYOCARDIAL FATTY ACID OXIDATION DEFECTS AND IMPROVES THE RESPONSE TO ACUTELY INCREASED AFTERLOAD

    Energy Technology Data Exchange (ETDEWEB)

    Ledee, Dolena; Portman, Michael A.; Kajimoto, Masaki; Isern, Nancy G.; Olson, Aaron

    2013-06-07

    Background: Subclinical hypothyroidism occurs during aging in humans and mice and may contribute to development of heart failure. Aging also impairs myocardial fatty acid oxidation, causing increased reliance on flux through pyruvate dehydrogenase (PDH) to maintain function. We hypothesize that the metabolic changes in aged hearts make them less tolerant to acutely increased work and that thyroid hormone reverses these defects. Methods: Studies were performed on young (Young, 4-6 months) and aged (Old, 22-24 months) C57/BL6 mice at standard (50 mmHg) and high afterload (80 mmHg). Another aged group received thyroid hormone for 3 weeks (Old-TH, high afterload only). Function was measured in isolated working hearts along with substrate fractional contributions (Fc) to the citric acid cycle (CAC) using perfusate with 13C labeled lactate, pyruvate, glucose and unlabeled palmitate and insulin. Results: Cardiac function was similar between Young and Old mice at standard afterload. Palmitate Fc was reduced but no individual carbohydrate contributions differed. CAC and individual substrate fluxes decreased in aged. At high afterload, -dP/dT was decreased in Old versus Young. Similar to low afterload, palmitate Fc was decreased in Old. Thyroid hormone reversed aging-induced changes in palmitate Fc and flux while significantly improving cardiac function. Conclusion: The aged heart shows diminished ability to increase cardiac work due to substrate limitations, primarily impaired fatty acid oxidation. The heart accommodates slightly by increasing efficiency through oxidation of carbohydrate substrates. Thyroid hormone supplementation in aged mice significantly improves cardiac function potentially through restoration of fatty acid oxidation.

  11. Contact therapy in the region of pharynx and oral cavity: Afterloading technique, irradiation planning, and results

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, P.; Bauer, M.; Fehrentz, D.; Zum Winkel, K.; Weidauer, H.; Singer, R.

    1985-05-01

    The contact irradiation in the region of pharynx and mouth with an afterloading unit is presented. Twelve patients with recurrent carcinomas of the squamous cell epithelium have been treated. A stable and reproducible positioning of the source probes in the tumor region is made possible by special applicator prostheses which are adapted to the post-operative situation. The irradiation scheme is based on the transformation of the source co-ordinates from the stereoradiographic localization system into the co-ordinate system of the computed tomogram. At least three fixed metal points which are inserted in the applicator prostheses and visualized by stereoradiography as well as by computed tomography serve as mutual reference points for both co-ordinate systems. The source positioning in the tumor region is optimized by CT irradiation planning. Three cases are presented in order to describe the principles of the method. Preliminary results are discussed.

  12. Five years hospital experience with the Amersham caesium 137 manual afterloading system

    Energy Technology Data Exchange (ETDEWEB)

    Bateman, T.J.; Davy, T.J.; Skeggs, D.B.L. (Royal Free Hospital, London (UK))

    1983-06-01

    The Amersham caesium 137 manual afterloading system for treatment of cancer of the uterine cervix and endometrium has been in use at the Royal Free Hospital for more than five years. The system uses permanently loaded flexible source pencils in combination with standard packs of disposable plastic applicators. Both sources and applicators have proved trouble-free in use. The sources are transported in special containers designed and built at the Royal Free Hospital and are inserted and removed on the ward by nursing staff. A set of sources is used in theatre for rectal and bladder dose measurements when the applicators are inserted. Staff radiation doses are low. The system is mainly used to produce pear-shaped dose distributions similar to those of the Manchester system, but simple cylindrical distributions are possible using symmetrically loaded source pencils.

  13. Análises de protocolos de braquiterapia, por alta taxa de dose, do controle de qualidade de alguns serviços locais, baseados no TG40, TG56 e ARCAL XXX Analysis of the high dose rate brachytherapy protocols of quality assurance programs of some local services, based on TG40, TG56 and ARCAL XXX.

    Directory of Open Access Journals (Sweden)

    Carmen S. Guzmán Calcina

    2001-08-01

    Full Text Available A braquiterapia por alta taxa de dose está recebendo atenção considerável na maioria dos países. Por isso, nos serviços que utilizam este equipamento exige-se que o desenvolvimento de um programa de controle de qualidade seja cada vez mais rigoroso, para garantir não apenas a segurança aos pacientes, mas também aos operadores e demais envolvidos. Este trabalho tem por objetivos fazer um levantamento dos tipos de testes para um equipamento de braquiterapia por alta taxa de dose, propostos pelos protocolos oficiais publicados (TG40, TG56 e ARCAL XXX e avaliar os tipos de testes que atualmente são realizados por alguns serviços de radioterapia, comparando-os com aqueles apresentados nos protocolos citados. Das análises feitas, observou-se que: a quanto aos protocolos oficiais, o TG56 é mais completo que o TG40 e o ARCAL XXX; b quanto às instituições analisadas, estas em geral se basearam no TG56 para elaborar seus próprios protocolos, os quais demonstraram ter também concordância com os outros já citados. Nestes protocolos, a inexistência dos testes anuais foi notada, o que pode ser explicado por sua aparição nas freqüências trimestral e semestral. Do produto deste estudo são apresentadas tabelas dos tipos de testes com suas respectivas freqüências de utilização, das quais um protocolo pode ser inferido para auxiliar na implementação, pelo menos, dos tipos de testes de controle de qualidade básicos e indispensáveis para o equipamento, garantindo, assim, um tratamento adequado aos pacientes e uma melhor segurança ao pessoal envolvido e, conseqüentemente, assegurando a garantia de qualidade na braquiterapia por alta taxa de dose.High dose rate brachytherapy has been increasingly recognized in most countries, and radiotherapy services using this equipment are encouraged to have a very efficient quality assurance program to ensure protection for patients, workers and other personnel involved. The objective of this

  14. A single session of intraluminal brachytherapy in palliation of oesophageal cancer

    NARCIS (Netherlands)

    Jager, J; Langendijk, H; Pannebakker, M; Rijken, J; deJong, J

    1995-01-01

    Between September 1987 and September 1993, 88 patients with oesophageal cancer were treated by a single session of intraluminal brachytherapy of 15 Gy prescribed at 1 cm distance from the central axis, using MDR Cs-137 (n = 51) during the first part of the study and HDR Ir-192 (n = 37) during the se

  15. High flip angle imaging of metallic stents: Implications for MR angiography and intraluminal signal interpretation

    NARCIS (Netherlands)

    Brück, E.H.; van Holten, J.; Wielopolski, P.; Pattynama, P.M.T.; van Dijk, L.C.

    2003-01-01

    Intraluminal stent signal characterization by MRI is generally hampered by signal loss from the metallic stent material. This signal loss is related to magnetic susceptibility and RF shielding. Even when stent materials with low magnetic susceptibility are used, RF shielding can still be problematic

  16. Disparity of isoflurane effects on left and right ventricular afterload and hydraulic power generation in swine.

    Science.gov (United States)

    Heerdt, P M; Gandhi, C D; Dickstein, M L

    1998-09-01

    The interaction between myocardial and vascular effects of anesthetics has a potential impact on how these drugs influence performance of the heart. Most studies have focused on volatile anesthetic effects on the left ventricle (LV) and systemic circulation. Whether the right ventricle (RV) and pulmonary circulation respond in a similar fashion, however, is unclear. In the present study, we therefore examined the dose-related effects of isoflurane on LV and RV contractility and total afterload and related changes to simultaneous effects on the hydraulic power generated by each chamber. Two groups of swine were studied: one received no additional treatment before isoflurane (ISO, n = 6), and the other received hexamethonium, atropine, and propranolol to produce autonomic blockade before isoflurane administration (ISO+AB, n = 4). For each experiment, measurements were made of RV and LV regional segment lengths and pressures, along with proximal aortic and pulmonary arterial (PA) blood flow and pressure during the administration of 0, 0.5, 1.0, and 1.5 minimum alveolar anesthetic concentration (MAC) isoflurane. Contractility was assessed by calculating the regional preload recruitable stroke work slope (PRSW). Afterload was characterized in both nonpulsatile and pulsatile terms by calculating aortic input impedance magnitude (Z). From these data, total arterial resistance (R), characteristic impedance (ZC), and vascular compliance (C) were determined with reference to a three-element Windkessel model of the circulation. Additionally, steady-state (WSS), oscillatory (WOS), and total (WT) hydraulic power output of each ventricle was calculated. In the ISO group, isoflurane produced a nearly threefold greater decrease of peak systolic pressure in the LV than in the RV, yet the dose-related decrease of regional PRSW was virtually the same in both chambers. In the aorta, isoflurane produced a maximal 25% reduction in R at 1.0 MAC and doubled C without a significant change

  17. Implication of uterine configuration on dosimetry to point A using the Amersham afterloading system.

    Science.gov (United States)

    Vedula, R

    1993-03-15

    Ninety-four biopsy-proven cases of cervix carcinoma who underwent brachytherapy with the flexible Amersham afterloading system are examined in this study. The uterine configuration showed a wide range with respect to the length, angle of version (indicated by angle alpha) and the degree of right or left shift of the midline at the internal os (indicated by angle beta). The manufacturers of the afterloading system have given certain precalculated dose rates to A which they derived from computer calculations for the various configurations of the system, for a particular loading strength of the Caesium 137 source trains, and for a particular range of angle alpha and beta. The study involves mathematical calculations of point A dose rates using post application radiographs, and a mean value of point A dose rate is derived to compare with other variables. A distortion of the uterus in the form of flexion (as opposed to version), resulting in bending of the uterine tandem is noted in 3 cases. There are 22% of cases with gross degree of retroversion (angle alpha more than 180 degrees) for which the precalculated tables are lacking. The angle beta, however, is in the normal range for all the cases but one. Nineteen cases (20.2%) showed point A dose rates which are beyond the specified dose rates of the manufacturers. Analysis of these 19 cases showed 6 cases with angle alpha more than 180 degrees, eight cases with more than a 10 degrees shift of the uterus to right or left of midline (angle beta) and the rest five cases have fairly normal values of these angles. Analysis of these five cases showed that three of them showed more than 8 CGy/hr difference in dose rates to individual points A right and left. An undue curvature of the uterine tandem to one side in the distal half, with a straight proximal half (near the anterior flange) is noted in these three cases. The angle alpha and beta are normal here since the nearest 2 cm of uterine tandem to the anterior flange is

  18. Intraluminal duodenal diverticulum causing recurrent pancreatitis: diagnostic role of computed tomography; Diverticulo duodenal intraluminal como causa de pancreatitis recidivante. Diagnostico mediante TC

    Energy Technology Data Exchange (ETDEWEB)

    Sanchis-Querol, E.; Abreu, J. A.; Canto, J.; Elizalde, A. [Hospital General d' Igualada. Barcelona (Spain)

    2000-07-01

    Intraluminal duodenal diverticulum is among the infrequent causes of pancreatitis. We present the case of a 23-year-old patient in which this congenital morphological anomaly was diagnosed as the cause of recurrent pancreatitis by means of computed tomography and upper gastrointestinal series. The radiological findings included a contrast-filled, sac-like structure partially occupying the second portion of the duodenum, from which it was separated by a band of radio lucent tissue (halo sign). We review the literature, comparing the findings of other authors with those observed in our patient. (Author) 8 refs.

  19. Adjuvant radiation therapy for the treatment of endometrial cancer: experience with combination of external radiation therapy and high-dose rate brachytherapy; Radioterapia adjuvante no tratamento do cancer de endometrio: experiencia com a associacao de radioterapia externa e braquiterapia de alta taxa de dose

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Michael Jenwei; Novaes, Paulo Eduardo Ribeiro Soares; Pellizzon, Antonio Cassio de Assis; Ferrigno, Robson; Fogaroli, Ricardo Cesar; Maia, Maria Aparecida Conte; Salvajoli, Joao Victor [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radioterapia]. E-mail: michael.chen@ig.com.br; Nishimoto, Ines Nobuko [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Centro de Estudos

    2005-12-01

    Objective: To review the results of adjuvant external beam radiation therapy (EBRT) combined with high-dose rate brachytherapy (HDR-BT) for the treatment of endometrial carcinoma. Materials and methods: We retrospectively evaluated 141 patients treated with EBRT and HDR-BT after surgery between January 1993 and January 2001. EBRT was performed with a median dose of 45 Gy, and HDR-BT was performed with a median dose of 24 Gy, with four weekly insertions of 6 Gy. The median age of the patients was 63 years and the disease stage distribution was: CS I (FIGO), 52.4%; CS II, 13.5%; CS III, 29.8%; CS IV, 4.3%. Results: With a median follow-up of 53.7 months, the disease free survival (DFS) at five years was: CS I, 88.0%; CS II, 70.8%; CS III, 55.1%; CS IV, 50.0% (p = 0.0003). Global survival after five years was: CS I, 79.6%; CS II, 74.0%; CS III, 53.6%; CS IV, 100.0% (p = 0.0062). Factors affecting the DFS were histological grade and serous-papillary histology. Recurrence of the disease was observed in 33 cases, 13 (9.2%) of these occurred in the pelvis, vagina or vaginal vault. EBRT + HDR-BT of the vaginal vault allowed disease control in 90.8% of the cases. Conclusion: Radiation therapy is essential for loco-regional control of endometrial cancer and can achieve excellent cure rates in the initial stages. In more advanced stages, therapeutic failure frequently appears as distant metastases suggesting the need for complementary systemic therapy using new treatment modalities, particularly chemotherapy. (author)

  20. Alumina ceramic as a biomaterial for use in afterloading radiation catheters for hyperthermia.

    Science.gov (United States)

    Ferraro, F T; Salcman, M; Broadwell, R D; Sewchand, W; Neuberth, G

    1989-08-01

    A major technical challenge to the use of interstitial hyperthermia in malignant brain tumors is the production of a well-defined, uniform hyperthermal field. In theory, A 915-MHz microwave antenna should allow fewer antennas to be used and cause less mechanical brain damage; however, standard radiation afterloading catheters require antennas to be 12 cm long; this is clearly impractical for intracranial use. Since alumina ceramic (Al2O3) catheters permit short microwave antennas (3-5 cm in length) to function properly in neural tissue, it is important to test the biocompatibility of alumina for use in combined interstitial microwave hyperthermia and brachytherapy. A 5-mm length of alumina catheter was implanted into the brains of 15 white rats. The animals were killed at 3, 7, 14, 28, and 56 days. Histological examination revealed only minor mechanical damage and no encapsulation until 1 month; even then, the glial wall was only a few cell layers thick. Five animals received implants and were killed at similar intervals for x-ray microanalysis with the scanning electron microscope. No migration of aluminum into the brain was detected when compared with two control animals that did not receive implants and an alumina blank. Although we measured 50% attenuation of the radiation from iridium-192 sources in alumina catheters as compared with conventional ones, alumina catheters can still be used for interstitial radiation by increasing either the activity of the seeds or the duration of treatment.

  1. Tracheostomaplasty: A surgical method for improving retention of an intraluminal stoma button for hands-free tracheoesophageal speech.

    Science.gov (United States)

    Moreno, Mauricio A; Lewin, Jan S; Hutcheson, Katherine A; Bishop Leone, Julie K; Barringer, Denise A; Reece, Gregory P

    2010-12-01

    We describe a minimally invasive surgical technique, tracheostomaplasty, to overcome anatomical deformities of the stoma that preclude successful retention of a stoma button for hands free tracheoesophageal (TE) speech. We conducted a retrospective analysis of 21 patients who underwent tracheostomaplasty after laryngectomy to accommodate an intraluminal valve attachment for hands-free TE speech. Sixteen men and 5 women (median age, 65 years; median follow-up, 27.7 months) underwent tracheostomaplasty; 6 patients developed a mild cellulitis that required therapy and 5 patients required a minor revision surgery. At last follow-up, 15 (71%) patients successfully achieved hands-free TE speech using an intraluminal stoma button. Three patients only retained the intraluminal device to facilitate digital occlusion. Tracheostomaplasty failed in 3 patients because of granulation tissue formation or stomal stenosis. Tracheostomaplasty is a successful technique to improve intraluminal retention of a stoma button for hands-free TE speech in laryngectomy patients.

  2. Acute small bowel obstruction due to a large intraluminal blood clot after laparoscopic Roux-en-Y gastric bypass

    Science.gov (United States)

    Green, Jessica; Ikuine, Tomoko; Hacker, Shoshana; Urrego, Hernan; Tuggle, Karleena

    2016-01-01

    Small bowel obstructions (SBOs) are a known perioperative complication of laparoscopic Roux-en-Y gastric bypass and common etiologies include internal hernia, port site hernia, jejunojejunostomy stricture, ileus and adhesions. Less commonly, SBO can be caused by superior mesenteric artery syndrome, intussusception and intraluminal blood clot. We present a case of SBO caused by intraluminal blood clot from jejunojejunostomy staple line bleeding in a patient with a normal coagulation profile. Computed tomography was used to elucidate the cause of perioperative SBO, and diagnostic laparoscopy was used to both diagnose and treat the complication. In this case, the intraluminal clot was evacuated laparoscopically by enterotomy, thrombectomy and primary closure without anastomotic revision since there was no evidence of continued bleeding. Administration of enoxaparin and Toradol post-operatively may have exacerbated mild intraluminal bleeding occurring at the stapled jejunojejunal anastomosis. Prompt recognition and treatment of perioperative SBO can prevent catastrophic consequences related to bowel perforation. PMID:27554828

  3. Intraluminal duodenal diverticulum: CT and gadoxetic acid-enhanced MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeong Myeong; Lee, Nam Kyung; Kim, Suk; Kim, Dong Uk; Kim, Tae Un [Dept. of Radiology, Pusan National University Hospital, Pusan National University School of Medicine, Busan (Korea, Republic of)

    2015-03-15

    Intraluminal duodenal diverticulum (IDD) is a rare congenital anomaly. IDD can become symptomatic in 20% to 25% of cases when complicated by intestinal obstruction, pancreatitis, or hemorrhage. We report the case of a 21-year-old female presenting with IDD mimicking duodenoduodenal intussusception. We describe the imaging features of IDD on the gadoxetic acid-enhanced magnetic resonance image as well as computed tomography.

  4. An intraluminal prosthesis may improve healing of a one-layer colonic anastomosis

    DEFF Research Database (Denmark)

    Buch, N; Glad, H; Svendsen, P;

    2002-01-01

    OBJECTIVE: To compare healing of one-layer colonic anastomoses with or without a soluble intraluminal prosthesis (* SBS-tube). DESIGN: Randomised, partly blinded controlled study. SETTING: University hospital, Denmark. SUBJECTS: 16 female Danish country strain pigs, of which 8 had the SBS tube...... of the anastomosis and may improve healing, possibly because of better apposition of the cut ends and reduced tension in the sutures....

  5. Long-term survival after intraluminal brachytherapy for inoperable hilar cholangiocarcinoma: A case report

    Institute of Scientific and Technical Information of China (English)

    Siu-Yin Chan; Ronnie T. Poon; Kelvin K. Ng; Chi-Leung Liu; Raymond T. Chan; Sheung-Tat Fan

    2005-01-01

    Surgical resection with a tumor-free margin is the onlycurative treatment for hilar cholangiocarcinoma (Klatskin tumor). However, over half of the patients present late with unresectable tumors. Radiotherapy using external beamirradiation or intraluminal brachytherapy (ILBT) has been used to treat unresectable hilar cholangiocarcinoma with satisfactory outcome. We reported a patient with unresectable hilar cholangiocarcinoma surviving more than 6 years after combined external beam irradiation and ILBT.

  6. Intraluminal Injection of Mesenchymal Stromal Cells in Spheroids Attenuates Experimental Colitis.

    Science.gov (United States)

    Molendijk, Ilse; Barnhoorn, Marieke C; de Jonge-Muller, Eveline S M; Mieremet-Ooms, Marij A C; van der Reijden, Johan J; van der Helm, Danny; Hommes, Daniel W; van der Meulen-de Jong, Andrea E; Verspaget, Hein W

    2016-08-01

    In recent years, mesenchymal stromal cells [MSCs] emerged as a promising therapeutic option for various diseases, due to their immunomodulatory properties. We previously observed that intraperitoneally injected MSCs in experimental colitis form spherical shaped aggregates. Therefore, we aggregated MSCs in vitro into spheroids and injected them intraluminally in mice with established colitis, to investigate whether these MSC spheroids could alleviate the colitis. We injected 0.5 x 10(6) MSCs in spheroids, 2.0 x 10(6) MSCs in spheroids, or phosphate-buffered saline [PBS] as a treatment control, via an enema in mice with established dextran sulphate sodium [DSS]-induced colitis. Body weight was measured daily and disease activity score was determined at sacrifice. Endoscopy was performed to evaluate mucosal healing. After sacrifice, both systemic and local inflammatory responses were evaluated. Intraluminally injected MSC spheroids alleviated DSS-induced colitis, resulting in significantly less body weight loss and lower disease activity score at sacrifice when a high dose of MSC spheroids was administered. However, the percentage of mucosal lesions in the distal colon and endoscopy scores were not significantly lower after treatment with 2.0 x 10(6) MSCs in spheroids compared with PBS-treated mice. Systemic inflammation marker serum amyloid A [SAA] was significantly reduced after treatment with 2.0 x 10(6) MSCs in spheroids. In addition, local cytokine levels of IFN-ɣ, TNF-α, IL-6, and IL-17a, as well as numbers of macrophages and neutrophils, showed a clear decrease-though not always significant-after intraluminal injection of the MSC spheroids. Intraluminally injected MSC spheroids at least partially attenuate experimental colitis, with fewer phagocytes and proinflammmatory cytokines, when a high dose of MSCs in spheroids was administered. Copyright © 2016 European Crohn’s and Colitis Organisation (ECCO). Published by Oxford University Press. All rights

  7. Huge ascending aortic aneurysm with an intraluminal thrombus in an embolic event-free patient.

    Science.gov (United States)

    Parato, Vito Maurizio; Prifti, Edvin; Pezzuoli, Franco; Labanti, Benedetto; Baboci, Arben

    2015-03-01

    We present a case of an 87-year-old male patient with a huge ascending aortic aneurysm, filled by a huge thrombus most probably due to previous dissection. This finding was detected by two-dimensional transthoracic echocardiography and contrast-enhanced computed tomography (CT) angiography scan. The patient refused surgical treatment and was medically treated. Despite the huge and mobile intraluminal thrombus, the patient remained embolic event-free up to 6 years later, and this makes the case unique.

  8. Positive intraluminal bowel contrast on computed tomography following oral ingestion of Kayexelate

    Energy Technology Data Exchange (ETDEWEB)

    Zissin, R.; Stackievicz, R.; Osadchy, A. [Tel-Aviv Univ., Dept. of Diagnostic Imaging Meir Medical Center, Kfar-Saba, affiliated to the Sackler School of Medicine, Tel-Aviv (Israel)], E-mail: zisinrivka@clalit.org.il; Gayer, G. [Tel-Aviv Univ., Dept. of Diagnostic Imaging Assaf Harofe Medical Center, Zrifin, affiliated to the Sackler School of Medicine, Tel-Aviv (Israel)

    2008-12-15

    Our study presents the computed tomography (CT) manifestations of orally ingested kayexelate (a powdered form of sodium polystyrene sulphonate) used to treat hyperkalemia. Five patients with whom kayexelate appeared as high-attenuating intraluminal enteric content, similar to oral contrast material or leakage of intravascular contrast, are reported. Radiologists should be familiar with its appearance as it may mimic oral or vascular contrast within the gastrointestinal tract, a finding that may lead to a diagnostic error or misinterpretation. (author)

  9. Relationships between motor patterns and intraluminal pressure in the 3-taeniated proximal colon of the rabbit.

    Science.gov (United States)

    Quan, Xiaojing; Yang, Zixian; Xue, Mai; Chen, Ji-Hong; Huizinga, Jan D

    2017-02-14

    Manometry is used worldwide to assess motor function of the gastrointestinal tract, and the measured intraluminal pressure patterns are usually equated with contraction patterns. In the colon, simultaneous pressure increases throughout the entire colon are most often called simultaneous contractions, although this inference has never been verified. To evaluate the relationship between pressure and contraction in the colon we performed high-resolution manometry and measured diameter changes reflecting circular muscle contractions in the rabbit colon. We show that within a certain range of contraction amplitudes and frequencies, the intraluminal pressure pattern faithfully resembles the contraction pattern. However, when the frequency is very high (as in fast propagating contractions in a cluster) the consequent intraluminal pressures merge. When the contraction speed of propagation is very fast (above ~5 cm/s), the resulting pressure occurs simultaneous throughout the colon; hence simultaneous pressure is measured as are caused by fast propagating contractions. The very slow propagating, low amplitude haustral boundary contractions show a very characteristic pattern in spatiotemporal contraction maps that is not faithfully reproduced in the pressure maps. Correct interpretation of pressure events in high-resolution manometry is essential to make it a reliable tool for diagnosis and management of patients with colon motor dysfunction.

  10. Evaluation of biochemical response on early prostate cancer: comparison between treatment with external beam radiation alone and in combination with high-dose rate conformal brachytherapy boost; Avaliacao da resposta bioquimica no cancer inicial de prostata: experiencia uninstitucional comparando teleterapia exclusiva ou associada a braquiterapia de alta taxa de dose

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Douglas Guedes de; Chen, Michael Jenwei; Pellizzon, Antonio Cassio Assis; Maia, Maria Aparecida Conte; Novaes, Paulo Eduardo Ribeiro dos Santos; Fogaroli, Ricardo Cesar; Ferrigno, Robson; Salvajoli, Joao Victor [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radioterapia]. E-mail: dougepm@uol.com.br; Nishimoto, Ines Nobuko [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Centro de Estudos

    2004-08-01

    Objective: To compare the biochemical response in patients with locally advanced prostate cancer treated with external beam radiation therapy alone or in combination with conformal brachytherapy boost. Materials and methods: From November 1997 to January 2000, 74 patients received 45 Gy of pelvic external irradiation and four were treated with high dose rate iridium-192 conformal boost implants of 4 Gy each (BT). These were compared with 29 other patients treated with 45 Gy of pelvic external irradiation followed by a 24 Gy of bilateral ARC boost (RT) from October 1996 to February 2000. Some patients received neoadjuvant androgen deprivation therapy. Three-year actuarial biochemical control rates (BC3) and pretreatment biochemical response predictors such as prostate-specific antigen pretreatment (PSAi), Gleason score (GS) and clinical stage (CS), were evaluated. Results: Median follow-up was of 25 months for the RT group and 37 months for the BT group. BC3 was 51% versus 73% (p = 0.032) for RT and BT, respectively. Comparisons of biochemical control by treatment group stratified by PSAi showed that BC3 for RT versus BT was 85.7% versus 79.1% (p = 0.76) for PSAi {<=}10 ng/mL and 38% versus 68% (p = 0.023) for PSAi > 10 ng/mL, respectively. For patients with GS {<=} 6, BC3 was 37% versus 80% (p = 0.001) for RT versus BT and, for patients with GS > 6, BC3 was 78% versus 55% (p = 0.58) for RT versus BT, respectively. For patients with CS {<=} T2a, BC3 was 36% versus 74% (p 0.018) for RT versus BT and, for patients with CS > T2a, BC3 was 73% versus 69% (p 0.692) for RT versus BT, respectively. The relative risk of biochemical relapse was 2.3 (95% IC: 1.0-5.1) for patients in RT group compared to the BT group. When adjusted for PSAi and GS, the relative risk of biochemical relapse was 2.4 (95% IC: 1.0-5.7). Conclusion: The treatment modality was an independent prognostic factor for biochemical relapse, with a significant improvement in the biochemical control with BT

  11. Braquiterapia endobronquial de alta tasa de dosis en pacientes con obstrucción de la vía aérea central: Experiencia en el Instituto Nacional del Cáncer y revisión de la literatura High dose rate endobronchial brachytherapy in patients with central airway obstruction

    Directory of Open Access Journals (Sweden)

    ALEJANDRO SANTINI B

    2010-09-01

    Full Text Available Introducción: La indicación principal de la braquiterapia endobronquial moderna (BTEB de alta tasa de dosis (HDR, es la paliación de síntomas por crecimiento endobronquial de cánceres pulmonares. Métodos: Se realizó BTEB HDR a 27 pacientes sintomáticos de patología tumoral endobronquial o traqueal, debido a patologías primarias bronquiales o secundarias metastásicas. Los tumores se ubicaban en tráquea, carina o a nivel bronquialproximal. Para observar mejorías en la sintomatología clínica, a todos se les realizó una fibrobroncoscopía (FBC para medir el grado de obstrucción bronquial e instalar catéteres endobronquiales de braquiterapia. Se administraron entre 1 y 4 fracciones de 7 a 7,5 Gy. Se registró subjetivamente la disnea, tos y hemoptisis antes y después del tratamiento, de acuerdo a una escala internacionalmente validada. Resultados: Tras el tratamiento todos los síntomas disminuyeron considerablemente, desapareciendo toda sintomatología severa. La hemoptisis y disnea desaparecieron en el 100% y 40% de los pacientes respectivamente, y la tos desapareció o disminuyó a grado leve en el 90% de los pacientes.Introduction: The main indication of modern high dose rate end bronchial brachyherapy (HDR EBBT is the palliation of symptoms related to the growth of the endobronchial lung cancer. Methods: EBBT was performed to 27 patients who suffered symptomatic tumoral endobronchial or tracheal pathology, due to primary bronchial disease or secondary metastasis cancer, evaluating the rate of clinical benefit. The tumors were located at tracheal, carinal or proximal bronchial level. Fibrobronchoscopy was performed to all the patients to measure the degree of airway obstruction and to install brachytherapy endobronchial catheters. Between 1 to 4 fractions of 7 to 7.5 Gy were administered. Dyspnea, cough and hemoptysis were subjectively registered before and after treatment, according to an international validated scale. Results

  12. Cirurgia conservadora, radioterapia externa e reforço de dose com braquiterapia de alta taxa de dose: uma nova perspectiva no tratamento de sarcomas de partes moles do adulto Limb-sparing surgery, external beam radiotherapy and boost with high-dose rate brachytherapy: a new perspective for the treatment of soft tissue sarcomas in adults

    Directory of Open Access Journals (Sweden)

    Antonio Cássio Assis Pellizzon

    2002-03-01

    Full Text Available OBJETIVO: Avaliar a influência no controle local de pacientes adultos e portadores de sarcoma de partes moles em extremidades e submetidos a cirurgia conservadora do membro, com braquiterapia de alta taxa de dose (BATD como reforço para a radioterapia externa (RT. MATERIAL E MÉTODOS: Foram avaliados 16 pacientes tratados, de 1993 até 1999. A RT foi utilizada com finalidade pré ou pós-operatória (30--55 Gy e BATD com dose de 18--36 Gy (fx 3--6 Gy BID. Com base no modelo linear quadrático calculou-se a dose efetiva biológica ("biological effective dose" - BED para o tumor e comparou-se seu valor a dados da literatura internacional, que utiliza tratamentos com RT e braquiterapia de baixa taxa de dose (BBTD. RESULTADOS: Os valores médios e medianos da BED para os sarcomas de partes moles foram de 78,5 Gy7 e 80 Gy7. A análise univariada mostrou que a BED para o tumor, quando utilizada BATD, era semelhante ao valor de 83 Gy7 quando utilizada BBTD (p = 0,008. As taxas de controle local, sobrevida livre de doença e sobrevida global atuarial em cinco anos foram de 83,2%, 75% e 93,7%, respectivamente. CONCLUSÕES: A BATD, quando utilizada como método complementar no reforço de dose da RT no tratamento conservador dos sarcomas de partes moles, apresenta taxas de controle local equiparáveis às da literatura internacional; no entanto, estudos com número maior de pacientes e período maior de seguimento são ainda necessários para determinar o verdadeiro potencial da BATD em substituir a BBTD.PURPOSE: To evaluate the influence on local control in adult patients with soft tissue sarcomas of the limbs that underwent limb-sparing surgery and high-dose rate brachytherapy (HDRB in association with teletherapy. MATERIAL AND METHODS: Sixteen patients treated from 1993 to 1999 were reviewed. Teletherapy was used pre- or postoperatively (30--55 Gy in association with HDRB in a dose range of 18--36 Gy (fx 3--6 Gy BID. The linear quadratic model was

  13. Characterization of TLD-100 in powders for dosimetric quality control of {sup 192} Ir sources used in brachytherapy of high dose rate; Caracterizacion de TLD-100 en polvo para control de calidad dosimetrico de fuentes de Ir{sup 192} usadas en braquiterapia de alta tasa de dosis

    Energy Technology Data Exchange (ETDEWEB)

    Loaiza C, S.P

    2007-07-01

    The Secondary Standard Dosimetric at the National Institute of Nuclear Research (ININ) calibrated a lot of powdered TLD-100 (LiF:Mg,Ti) in terms of absorbed dose to water D{sub w} for the energy of: {sup 60}Co, {sup 137C}s, X rays of 250 and 50 kVp. Later on, it is carried out an interpolation of the calibration for the energy of the {sup 192}Ir. This calibration is part of a dosimetric quality control program, to solve the problems of traceability for the measurements carried out by the users of {sup 192}Ir sources employed in the treatments of High Dose Rate Brachytherapy (HDR) at the Mexican Republic. The calibrations of the radiation beams are made with the following protocols: IAEA TRS-398 for the {sup 60}Co for D{sub w}, using a secondary standard ionization chamber PTW N30013 calibrated in D{sub w} by the National Research Council (NRC, Canada). AAPM TG-43 for D{sub w} in terms of the strength kerma Sk, calibrating this last one quantity for the {sup 137}Cs radioactive source, with a well chamber HDR 1000 PLUS traceable to the University of Wisconsin (US). AAPM TG-61 for X ray of 250 and 50 kVp for D{sub w} start to Ka using field standard a Farmer chamber PTW 30001 traceable to K for the Central Laboratory of Electric Industries (CLEI, France). The calibration curves (CC) they built for the response of the powder TLD: R{sub TLD} vs D{sub w}: For the energy of {sup 60}Co, {sup 137}Cs, X rays of 250 and 50 kVp. Fitting them with the least square method weighed by means of a polynomial of second grade that corrects the supra linearity of the response. iii. Each one of the curves was validated with a test by lack of fitting and for the Anderson Darling normality test, using the software MINITAB in both cases. iv. The sensibility factor (F{sub s}) for each energy corresponds to the slope of the CC, v. The F{sub s} for the two {sup 192}Ir sources used are interpolated: one for a Micro Selectron source and the other one a Vari Source source. Finally, a couple of

  14. Tracking neutrophil intraluminal crawling, transendothelial migration and chemotaxis in tissue by intravital video microscopy.

    Science.gov (United States)

    Xu, Najia; Lei, Xi; Liu, Lixin

    2011-09-24

    The recruitment of circulating leukocytes from blood stream to the inflamed tissue is a crucial and complex process of inflammation(1,2). In the postcapillary venules of inflamed tissue, leukocytes initially tether and roll on the luminal surface of venular wall. Rolling leukocytes arrest on endothelium and undergo firm adhesion in response to chemokine or other chemoattractants on the venular surface. Many adherent leukocytes relocate from the initial site of adhesion to the junctional extravasation site in endothelium, a process termed intraluminal crawling(3). Following crawling, leukocytes move across endothelium (transmigration) and migrate in extravascular tissue toward the source of chemoattractant (chemotaxis)(4). Intravital microscopy is a powerful tool for visualizing leukocyte-endothelial cell interactions in vivo and revealing cellular and molecular mechanisms of leukocyte recruitment(2,5). In this report, we provide a comprehensive description of using brightfield intravital microscopy to visualize and determine the detailed processes of neutrophil recruitment in mouse cremaster muscle in response to the gradient of a neutrophil chemoattractant. To induce neutrophil recruitment, a small piece of agarose gel (~1-mm(3) size) containing neutrophil chemoattractant MIP-2 (CXCL2, a CXC chemokine) or WKYMVm (Trp-Lys-Tyr-Val-D-Met, a synthetic analog of bacterial peptide) is placed on the muscle tissue adjacent to the observed postcapillary venule. With time-lapsed video photography and computer software ImageJ, neutrophil intraluminal crawling on endothelium, neutrophil transendothelial migration and the migration and chemotaxis in tissue are visualized and tracked. This protocol allows reliable and quantitative analysis of many neutrophil recruitment parameters such as intraluminal crawling velocity, transmigration time, detachment time, migration velocity, chemotaxis velocity and chemotaxis index in tissue. We demonstrate that using this protocol, these

  15. Intraluminal versus infiltrating gallbladder carcinoma: Clinical presentation, ultrasound and computed tomography

    Institute of Scientific and Technical Information of China (English)

    Tze-Yu Lee; Sheung-Fat Ko; Chung-Cheng Huang; Shu-Hang Ng; Jiun-Lung Liang; Hsuan-Ying Huang; Min-Chi Chen; Shyr-Ming Sheen-Chen

    2009-01-01

    AIM: To compare clinical presentation and ultrasound (US) and computed tomography (CT) sensitivity between intraluminal and infiltrating gallbladder carcinoma (GBCA).METHODS: This retrospective study evaluated 65 cases of GBCA that were categorized morphologically into the intraluminal-GBCA ( n = 37) and infiltrating-GBCA ( n = 28) groups. The clinical and laboratory findings, presence of gallstones, gallbladder size, T-staging, nodal status, sensitivity of preoperative US and CT studies,and outcome were compared between the two groups.RESULTS: There were no significant differences between the two groups with respect to female predominance,presence of abdominal pain, serum aminotransferases level, T2-T4 staging, and regional metastatic nodes.Compared with the patients with intraluminal-GBCA, those with infiltrating-GBCA were significantly older (65.49 ± 1.51 years vs 73.07 ± 1.90 years), had a higher frequency of jaundice (3/37 patients vs 13/28 patients) and fever (3/37 patients vs 10/28 patients), higher alkaline phosphatase (119.36 ± 87.80 IU/L vs 220.68 ± 164.84 IU/L) and total bilirubin (1.74 ± 2.87 mg/L vs 3.50 ± 3.51 mg/L) levels, higher frequency of gallstones (12/37 patients vs 22/28 patients), smaller gallbladder size (length, 7.47 ± 1.70 cm vs 6.47 ± 1.83 cm; width, 4.21 ± 1.43 cm vs 2.67 ± 0.93 cm), and greater proportion of patients with < 12 mo survival (16/37 patients vs 18/28 patients). The sensitivity for diagnosing intraluminal- GBCA with and without gallstones was 63.6% and 91.3% by US, and 80% and 100% by CT, respectively.The sensitivity for diagnosing infiltrating-GBCA with and without gallstones was 12.5% and 25% by US, and 71.4% and 75% by CT, respectively.CONCLUSION: In elderly women exhibiting small gallbladder and gallstones on US, especially those with jaundice, fever, high alkaline phosphatase and bilirubin levels, CT may reveal concurrent infiltrating-GBCA.

  16. Monte Carlo derivation of AAPM TG-43 dosimetric parameters for GZP6 Co-60 HDR sources.

    Science.gov (United States)

    Tabrizi, Sanaz Hariri; Asl, Alireza Kamali; Azma, Zohreh

    2012-04-01

    Cobalt 60 source is generally available on high dose rate (HDR) afterloading equipment especially for treatment of gynecological lesions. The GZP6 remote afterloader (Nuclear Power Institute of China) utilizes (60)Co sources for treatment of intracavitary and intraluminal malignancies. In this study, the AAPM TG-43 dosimetric parameters of three sources in GZP6 system have been studied using MCNP4C Monte Carlo (MC) code; and the results are compared with other available (60)Co HDR sources. The presented parameters consist of air kerma strength, dose rate constant, radial dose function and anisotropy function. They show less than 1% uncertainty. The TG-43 based dosimetry data can be used not only to validate the dedicated treatment planning software (TPS), but also to introduce new complementary software to enhance the system performance in gynecological treatments.

  17. Breast conserving treatment of breast carcinoma T2 ({<=} 4 cm) and T3 by neoadjuvant chemotherapy, quadrantectomy, high dose rate brachytherapy as a boost, external beam radiotherapy and adjuvant chemotherapy: local control and overall survival analysis; Tratamento conservador do cancer de mama T2 ({<=} 4 cm) e T3 por quimioterapia neoadjuvante, quadrantectomia, braquiterapia com alta taxa de dose como reforco de dose, teleterapia complementar e quimioterapia adjuvante: analise de controle local e sobrevida global

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Celia Regina; Miziara Filho, Miguel Abrao; Fogaroli, Ricardo Cesar; Baraldi, Helena Espindola; Pellizzon, Antonio Cassio Assis; Pelosi, Edilson Lopes [Instituto do Cancer Dr. Arnaldo Vieira de Carvalho (ICAVC), Sao Paulo, SP (Brazil). Servico de Radioterapia], e-mail: celiarsoares@terra.com.br; Fristachi, Carlos Elias [Instituto do Cancer Dr. Arnaldo Vieira de Carvalho (ICAVC), Sao Paulo, SP (Brazil). Servico de Onco-Ginecologia e Mastologia; Paes, Roberto Pinto [Instituto do Cancer Dr. Arnaldo Vieira de Carvalho (ICAVC), Sao Paulo, SP (Brazil)

    2008-12-15

    Objective: to assess the treatment of breast cancer T2 ({<=} 4 cm) and T3 through neoadjuvant chemotherapy, quadrantectomy and high dose rate brachytherapy as a boost, complementary radiotherapy and adjuvant chemotherapy, considering local control and overall survival. Material and method: this clinical prospective descriptive study was based on the evaluation of 88 patients ranging from 30 to 70 years old, with infiltrating ductal carcinoma, clinical stage IIb and IIIa, responsive to the neoadjuvant chemotherapy, treated from June/1995 to December/2006. Median follow-up was 58 months. Using clinical methods the tumor was evaluated before and after three or four cycles of chemotherapy based on anthracyclines. Overall survival and local control were assessed according to Kaplan-Meier methodology. Results: Local control and overall survival in five years were 90% and 73.5%, respectively. Conclusion: local control and overall survival were comparable to other forms of treatment. (author)

  18. Thyroid hormone reverses aging-induced myocardial fatty acid oxidation defects and improves the response to acutely increased afterload.

    Directory of Open Access Journals (Sweden)

    Dolena Ledee

    Full Text Available BACKGROUND: Subclinical hypothyroidism occurs during aging in humans and mice and may contribute to the development of heart failure. Aging also impairs myocardial fatty acid oxidation, causing increased reliance on flux through pyruvate dehydrogenase (PDH to maintain function. We hypothesize that the metabolic changes in aged hearts make them less tolerant to acutely increased work and that thyroid hormone supplementation reverses these defects. METHODS: Studies were performed on young (Young, 4-6 months and aged (Old, 22-24 months C57/BL6 mice at standard (50 mmHg and high afterload (80 mmHg. Another aged group received thyroid hormone for 3 weeks (Old-TH, high afterload only. Function was measured in isolated working hearts along with substrate fractional contributions (Fc to the citric acid cycle (CAC using perfusate with (13C labeled lactate, pyruvate, glucose and unlabeled palmitate and insulin. RESULTS: Old mice maintained cardiac function under standard workload conditions, despite a marked decrease in unlabeled (presumably palmitate Fc and relatively similar individual carbohydrate contributions. However, old mice exhibited reduced palmitate oxidation with diastolic dysfunction exemplified by lower -dP/dT. Thyroid hormone abrogated the functional and substrate flux abnormalities in aged mice. CONCLUSION: The aged heart shows diminished ability to increase cardiac work due to substrate limitations, primarily impaired fatty acid oxidation. The heart accommodates slightly by increasing efficiency through oxidation of carbohydrate substrates. Thyroid hormone supplementation in aged mice significantly improves cardiac function potentially through restoration of fatty acid oxidation.

  19. Inhibition of early AAA formation by aortic intraluminal pentagalloyl glucose (PGG) infusion in a novel porcine AAA model

    DEFF Research Database (Denmark)

    Kloster, Brian O; Lund, Lars; Lindholt, Jes S

    2016-01-01

    to prevent or delay their expansion. In this study, we investigated whether intraluminal delivered pentagalloyl glucose (PGG) can impair the early AAA development in a porcine model. METHODS: The infrarenal aorta was exposed in thirty pigs. Twenty underwent an elastase based AAA inducing procedure and ten...... of these received an additional intraluminal PGG infusion. The final 10 were sham operated and served as controls. RESULTS: All pigs who only had an elastase infusion developed macroscopically expanding AAAs. In pigs treated with an additional PGG infusion the growth rate of the AP-diameter rapidly returned...... and histology. CONCLUSION: In our model, intraluminal delivered PGG is able to penetrate the aortic wall from the inside and impair the early AAA development by stabilizing the elastic lamellae and preserving their integrity. The principle holds a high clinical potential if it can be translated to human...

  20. The Effect of Sparkling Water on Intraluminal Formulation Behaviour and Systemic Drug Performance.

    Science.gov (United States)

    Van Den Abeele, Jens; Brouwers, Joachim; Deloose, Eveline; Tack, Jan; Augustijns, Patrick

    2017-04-06

    In the context of mediating intra- and inter-individual variability in systemic drug exposure after oral drug administration, this small-scale, crossover study aimed to investigate the effect of drug intake with sparkling water on fasted state gastric motor function and subsequent (variability in) intraluminal and systemic drug disposition. For this purpose, healthy human volunteers were asked to ingest a conventional paracetamol tablet with either tap or sparkling water, after which antroduodenal motility as well as intraluminal and systemic drug disposition were monitored as a function of time. Ingestion of sparkling water led to the occurrence of transient pressure events in the upper gastrointestinal tract for all volunteers, although the duration and frequency of the observed effect were subject to variability. Based on systemic drug disposition parameters, drug intake with sparkling water resulted in a trend towards faster and less variable absorption of paracetamol from the gastrointestinal tract. Faster and less variable intragastric tablet disintegration, due to (i) a direct effect (i.e. in vivo dissolution rate) and/or (ii) an indirect effect (i.e. gastrointestinal motility) of sparkling water, is likely to contribute to this observation.

  1. Intraluminal magnetisation of bowel by ferromagnetic particles for retraction and manipulation by magnetic probes.

    Science.gov (United States)

    Wang, Z; André, P; McLean, D; Brown, S I; Florence, G J; Cuschieri, A

    2014-11-01

    Feasibility studies are needed to demonstrate that safe and effective manipulation of bowel during Minimal Access Surgery (MAS) can be obtained by use of magnetic force. This paper characterises two classes of magnetic particles: stainless steel microparticles (SS-μPs) and iron oxide nanoparticles (IO-nPs) in terms of their magnetisation, chemical composition, crystallinity, morphology and size distribution. Both magnetic particles were dispersed in a high viscosity biological liquid for intraluminal injection of bowel. Ex vivo porcine bowel segments were then retracted by permanent magnetic probes of 5.0 and 10mm diameter. Strong retraction forces reaching 6N maximum were obtained by magnetic fluid based on dispersion of SS-μPs. In contrast, the IO-nP-based magnetic liquid generated less attraction force, due to both lower magnetic and solution properties of the IO-nPs. The comparison of the two particles allowed the identification of the rules to engineer the next generation of particles. The results with SS-μPs provide proof on concept that intraluminal injection of magnetic fluid can generate sufficient force for efficient bowel retraction. Thereafter we shall carry out in vivo animal studies for efficacy and safety of both types of ferrofluids.

  2. Successful Treatment of a Large Pelvic Abscess Using Intraluminal VAC: A Case Report.

    Science.gov (United States)

    Aras, Abbas; Celik, Sebahattin; Kiziltan, Remzi; Yilmaz, Özkan; Kotan, Çetin

    2016-04-01

    The most feared complication of the surgical treatment of rectal cancer is anastomotic leakage, which is related to high rates of mortality and morbidity. Here, we present a patient who could not be treated with surgical drainage but treated by intraluminal Vacuum Associated Closure (VAC). A 34-year-old male patient was treated for rectal cancer by low anterior resection, colorectal anastomosis, and diverting ileostomy following neoadjuvant CRT. The patient reported with a postoperative anastomotic disruption and a large pelvic abscess. Due to the continuation of foul-smell drainage inspite of perianal incision and drainage, intraluminal VAC was applied and the pelvic abscess and the foul-smell were successfully treated. The presence of an adequate anal sphincter tonus is a disadvantage in anastomotic leakage, since it prevents the emptying of the intestinal content and also precludes the drainage of the pelvic abscess. The endoluminal application of VAC, similar to the results of application of VAC in open wounds, has been demonstrated to decrease fibrin and necrotic tissue in the pelvic cavity and increase granulation tissue. VAC, which has long been used in the treatment of open wounds, is a promising method in the treatment of large pelvic abscesses due to anastomotic leakage following rectum resection.

  3. An isoprenylation and palmitoylation motif promotes intraluminal vesicle delivery of proteins in cells from distant species.

    Science.gov (United States)

    Oeste, Clara L; Pinar, Mario; Schink, Kay O; Martínez-Turrión, Javier; Stenmark, Harald; Peñalva, Miguel A; Pérez-Sala, Dolores

    2014-01-01

    The C-terminal ends of small GTPases contain hypervariable sequences which may be posttranslationally modified by defined lipid moieties. The diverse structural motifs generated direct proteins towards specific cellular membranes or organelles. However, knowledge on the factors that determine these selective associations is limited. Here we show, using advanced microscopy, that the isoprenylation and palmitoylation motif of human RhoB (-CINCCKVL) targets chimeric proteins to intraluminal vesicles of endolysosomes in human cells, displaying preferential co-localization with components of the late endocytic pathway. Moreover, this distribution is conserved in distant species, including cells from amphibians, insects and fungi. Blocking lipidic modifications results in accumulation of CINCCKVL chimeras in the cytosol, from where they can reach endolysosomes upon release of this block. Remarkably, CINCCKVL constructs are sorted to intraluminal vesicles in a cholesterol-dependent process. In the lower species, neither the C-terminal sequence of RhoB, nor the endosomal distribution of its homologs are conserved; in spite of this, CINCCKVL constructs also reach endolysosomes in Xenopus laevis and insect cells. Strikingly, this behavior is prominent in the filamentous ascomycete fungus Aspergillus nidulans, in which GFP-CINCCKVL is sorted into endosomes and vacuoles in a lipidation-dependent manner and allows monitoring endosomal movement in live fungi. In summary, the isoprenylated and palmitoylated CINCCKVL sequence constitutes a specific structure which delineates an endolysosomal sorting strategy operative in phylogenetically diverse organisms.

  4. Pharmacokinetics of intraluminally administered serum papaverine for spasm prophylaxis of the internal mammary artery.

    Science.gov (United States)

    Kiessling, Arndt-Holger; Romasku, Deniss; Beiras-Fernandez, Andres; Ferreirós, Nerea; Labocha, Sandra; Moritz, Anton; Rastan, Ardawan Julian

    2013-10-01

    Papaverine (Paveron N™ Linden Arzneimittel Vertrieb GmbH, Germany) is a widely used agent for preventing spasm in mammary artery preparations. The question addressed in this study is whether the intraluminal administration of papaverine can result in detectable absorption of the drug into the systemic arterial circulation. In 15 patients (age 65 ± 6 years; body mass index 28.9 ± 3.7), an internal mammary artery (IMA) was prepared during coronary artery bypass grafting (CABG). A maximum of 3 mL of a 1 mg/1 mL diluted papaverine solution was injected intravascularly (intraluminally) for spasm prophylaxis. The IMA was closed proximally and distally with bulldog clamps. Blood samples were taken immediately after administration (T1), after 20 minutes (T2), and at the end of the operation (T3). Samples were measured in a liquid chromatography-tandem mass spectrometry (LC-MS/MS) system consisting of a binary pump from Agilent (Waldbronn, Germany) coupled to a high-throughput screening (HTS) PAL injection system (CTC, Zwingen, Switzerland) and a tandem mass spectrometer (API 4000, AB Sciex, Darmstadt, Germany). Papaverine was analyzed in positive mode using an electrospray ion source. Quantitation was performed using Analyst 1.5 software (AB Sciex, Darmstadt, Germany). The newly developed LC-MS/MS method was successfully established for the detection of papaverine in plasma samples. The highest plasma papaverine levels were determined at time point T1 (mean 54.7 ± 39 ng/mL, range 16.6-179 ng/mL). The concentration was already halved 20 minutes after administration (T2) (mean 23.3 ± 2 ng/mL, range 4.6-118 ng/mL). Because of the short half-life and the hemodilution in the extracorporeal circulation, at the end of the operation papaverine (T3) had already fallen to just above the limit of detection (mean 4.1 ± 3.9 ng/mL, range 1.3-16.9 ng/mL). At time point T1, a significant negative correlation was determined between plasma levels and systemic diastolic, but not

  5. Pretreatment with intraluminal rapamycin nanoparticle perfusion inhibits neointimal hyperplasia in a rabbit vein graft model

    Directory of Open Access Journals (Sweden)

    Kai Liu

    2010-10-01

    Full Text Available Kai Liu1*, Guangqing Cao1*, Xiquan Zhang1, Ruifang Liu2, Weiwei Zou3, Shuming Wu11Departments of Cardiovascular Surgery, 2Anesthesia, Qilu Hospital of Shandong University, Jinan; 3The School of Pharmaceutical Science, Shandong University, Jinan, Shandong, People’s Republic of China; *Kai Liu and Guangqing Cao contributed equally to this work.Purpose: Poly lactic-co-glycolic acid nanoparticles (PLGA-NP are widely used as a biodegradable biomaterial in medicine. Rapamycin-eluting stents have been used for prevention of restenosis during surgery. This study investigated the effect of pretreatment with intraluminal perfusion of carbopol-encapsulated rapamycin-loaded PLGA nanoparticles (RAP-PLGA-NP on neointimal hyperplasia in a rabbit vein graft model.Methods: A segment of common carotid artery was replaced with a segment of external jugular vein in 60 rabbits which were then separated into four treatment groups, ie, Group 1, in which vein grafts were pretreated with intraluminal RAP-PLGA-NP perfusion, Group 2 in which vein grafts underwent equivalent empty vehicle (PLGA-NP perfusion, Group 3, in which vein grafts received no treatment, and Group 4, which served as a sham operation group receiving normal vein contrast. On postoperative day 28, the grafts and normal veins were harvested for histologic examination, flow cytometry analysis, and high-performance liquid chromatography measurement.Results: Compared with Group 1, the intima of the grafts were thickened, the ratio of intimal area to vessel area increased, and the collagen volume index of the vein grafts increased significantly in Groups 2 and 3. The cell proliferation index in Group 1 (21.11 ± 3.15% was much lower than that in Group 2 (30.35 ± 2.69% and in Group 3 (33.86 ± 8.72%. By high-performance liquid chromatography measurement, retention of rapamycin was detected in Group 1 (11.2 ± 0.37 µg/10 mg 28 days after single drug perfusion.Conclusion: Pretreatment with intraluminal RAP

  6. New method for the induction of therapeutic amenorrhea: low dose endometrial afterloading irradiation. Clinical and hormonal studies

    Energy Technology Data Exchange (ETDEWEB)

    Gronroos, M.; Turunen, T.; Raekallio, J.; Ruotsalinen, P.; Salmi, T. (Turku Univ. (Finland). Dept. of Obstetrics and Gynecology)

    1982-08-01

    The authors present a new method for the induction of therapeutic amenorrhea: low dose endometrial afterloading irradiation. The problem with this method has been how to inactivate the endometrium while maintaining the physiological function of the ovaries. In 5/29 young patients regular or irregular bleedings occurred after an endometrial dose of 11+-1 Gy. These subjects were given a repeat low dose intrauterine irradiation. Thereafter no bleedings were found in four out of five patients. Two to 9 years after the repeat irradiation the plasma levels of E/sub 1/, E/sub 2/, FSH and LH corresponded closely to those of healthy women in reproductive age in three out of five patients; some high plasma P levels indicated ovulation. In two patients the E/sub 1/, E/sub 2/, and P values were more likely postmenopausal but, on the other hand, FSH and LH values reproductive ones. 19 refs.

  7. Tratamento cirúrgico em dois tempos do aneurisma toracoabdominal roto com prótese intraluminal sem sutura

    National Research Council Canada - National Science Library

    BERNARDES, Rodrigo de Castro; REIS FILHO, Fernando A. Roquete; LIMA, Cláudio Moreira; GONÇALVES, Leonardo D'Ávila; OLIVEIRA, Marília M. Cedin; CASSÉTE, Luciana T. Fernandes; MONTEIRO, Ernesto Lentz da Silveira; MELLO, José Marcelo Coutinho de

    1998-01-01

    ... prótese intraluminal sem sutura (5, 6). Esta técnica nos proporciona uma operação menos agressiva por abordar somente o segmento roto da aorta, portanto apenas uma cavidade é manipulada (tórax ou abdome...

  8. Abdominal aortic aneurysm, arterial stiffening and the role of the intraluminal thrombus

    DEFF Research Database (Denmark)

    Lyck Hansen, Maria; Dahl Thomsen, Marie; Melholt Rasmussen, Lars

    2015-01-01

    PATIENTS AND METHODS: PWV and PWA were measured in male patients with AAA from an ongoing Danish AAA screening trial. Information on blood pressure, medications, BMI and smoking status was obtained at inclusion. RESULTS: In total, 157 patients were included. Mean age was 73 years. Mean AAA size...... was 42.2 mm. Fifty-six of the patients had an intraluminal thrombus, and patients with AAA and ILT had a significantly higher Aix75 than patients with AAA but without ILT (Mean = 28.3 ± 1.4 SEM vs. 24.9 ± 0.81, p=0.027), a difference that was also significant when adjusting for AAA size, blood pressure...... and age. There was no difference in PWV between the groups. CONCLUSIONS: Haemodynamic properties of the aorta are affected by the presence of ILT in patients with AAA that is not explained by aortic size. Alternatively, these findings could be explained by associations between ILT and properties...

  9. Simultaneous measurement of intraluminal pressure and pH in the stomach and oesophagus

    Science.gov (United States)

    Lockwood, Knud; Borgeskov, Sven

    1969-01-01

    A short survey is given of the theoretical background for the simultaneous measurement of intraluminal pressure and pH in the oesophagus and stomach as well as the method used in the paper presented. In 20 of 23 patients with symptoms of regurgitation this was sustained by the pH measurement (87%). In only 20% was incompetence demonstrated radiologically. The pH measurement is of especial value in the diagnosis of oesophageal reflux. The value of simultaneous pressure measurements is to ascertain the position of the electrode distally or proximally to the oesophageal hiatus. Thus we suggest that pressure and pH measurements are mandatory in future post-operative follow-up examinations in patients operated upon for hiatal herniae. Images PMID:5348327

  10. Further experience with modification of an intraluminal button for hands-free tracheoesophageal speech after laryngectomy.

    Science.gov (United States)

    Lewin, Jan S; Montgomery, Patti C; Hutcheson, Katherine A; Chambers, Mark S

    2009-11-01

    Tracheoesophageal (TE) speech using a voice prosthesis and hands-free speaking valve with an intraluminal attachment is the gold standard for voice restoration after total laryngectomy. Modification of a standard self-retaining silicone cannula or laryngectomy button often aids in the attachment of a speaking valve within the tracheal lumen for hands-free TE speech production. An increased number of laryngectomized individuals are able to achieve hands-free TE speech when the standard length, flange, and diameter of a silicone button is customized to accommodate individual tracheostomal contours. A technique is presented for modification of a standard silicone laryngectomy button to facilitate hands-free TE speech after total laryngectomy.

  11. Iron-Deficiency Anemia Leading to Transient Ischemic Attacks due to Intraluminal Carotid Artery Thrombus

    Directory of Open Access Journals (Sweden)

    H. Z. Batur Caglayan

    2013-01-01

    Full Text Available Reactive thrombocytosis secondary to iron-deficiency anemia (IDA is a rare but recognized cause of stroke. We report the case of a patient with iron-deficiency anemia presenting with multiple transient ischemic attacks (TIA due to intraluminal thrombus of an internal carotid artery. The putative mechanisms underlying anemia and stroke syndromes are not completely understood, and it is believed that iron deficiency may cause ischemic stroke by several potential mechanisms. Thrombocytosis is often associated with iron deficiency, and microcytosis produces a reduction in the red cell deformability and could produce a hypercoagulable state. The platelet count and function observed in iron-deficiency anemia could act synergistically to promote thrombus formation, especially in the setting of an underlying atherosclerotic disease. The presence of floating thrombus in a patient with clinical and MRI evidence of stroke represents a significant therapeutic dilemma and requires immediate decision about treatment.

  12. Nylon filament coated with paraffin for intraluminal permanent middle cerebral artery occlusion in rats.

    Science.gov (United States)

    Zuo, Xia-Lin; Wu, Ping; Ji, Ai-Min

    2012-06-21

    A variety of intraluminal nylon filament has been used in rat middle cerebral artery occlusion (MCAO) models. However the lesion extent and its reproducibility vary among laboratories. The properties of nylon filament play a part of reasons for these variations. In the present study, we used paraffin-coated nylon filament for rat MCAO model, tested the effects and advanced improvement for making the rat MCAO. Forty male Sprague-Dawley (SD) rats were randomized into two groups, MCAO with traditional uncoated nylon filament (uMCAO) and MCAO with paraffin-coated nylon filament (cMCAO), three rats as normal group and sham group respectively. Assessment included mortality rates, model success rates, neurological deficit evaluation, and infarct volume. The study showed two rats died in uMCAO group, no rat died in cMCAO group within the 12h. The model success rate of uMCAO was 100%, while the uMCAO group was 55% (n=20, two died within 12h, seven rats were excluded as the brain slices showed no TTC staining due to subarachanoid hemorrhage). Neurological evaluation demonstrated group cMCAO had more worse neurological outcomes than group uMCAO, and the difference was statistically signification (pparaffin-coated nylon filament intraluminal occlusion provide better occlusion of middle cerebral artery than the uncoated nylon filament, improve the consistent of model, and raise the success rate to reduce the number of experimental animals. These positive results are much encouraging and interesting. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  13. Impedancia esofágica intraluminal de canal múltiple: una nueva frontera en motilidad Multichannel intraluminal esophageal impedance: A new frotier in motility

    Directory of Open Access Journals (Sweden)

    F. de la Morena

    2008-02-01

    Full Text Available La impedancia esofágica multicanal constituye una de las más recientes herramientas diagnósticas aplicadas a la evaluación de la enfermedad por reflujo gastroesofágico. Esta técnica se basa en la monitorización continua de la conductividad eléctrica en un medio, en este caso el esófago, a través de electrodos situados en la longitud de una sonda, y en los cambios que un elemento como el bolo alimentario puede producir en dicha variable. De esta técnica se derivan nuevas perspectivas en la exploración de la función esofágica y de la enfermedad por reflujo gastroesofágico, hasta ahora sólo cuantificable de forma indirecta por las fluctuaciones generadas por los cambios en el pH del reflujo ácido. Presentamos el caso de una paciente con tos persistente evaluada con este procedimiento, en quien se demostró la presencia de reflujo gastroesofágico débilmente ácido que no pudo ser demostrado previamente con otras exploraciones, y de cómo la impedancia descartó la asociación entre este síntoma y el reflujo no ácido.Multichannel intraluminal impedance is a new technique for evaluating esophageal function and gastroesophageal reflux disease (GERD. This technique relies on the monitoring of electric conductivity in the esophagus though electrodes, and on changes developing in this variable as a result of bolus passage. The proximal distribution and duration of non-acid reflux events can now be quantified, and combined manometry defines the effectiveness of esophageal body function, until now only indirectly evaluated with pH changes. We discuss the case of a woman with persistent cough in whom intraesophageal multichannel impedance demostrates a minor acid reflux that could not be demonstrated with other diagnostic methods previously, and how this technique excludes any association between cough and non-acid reflux.

  14. Human factors evaluation of remote afterloading brachytherapy. Supporting analyses of human-system interfaces, procedures and practices, training and organizational practices and policies. Volume 3

    Energy Technology Data Exchange (ETDEWEB)

    Callan, J.R.; Kelly, R.T.; Quinn, M.L. [Pacific Science & Engineering Group, San Diego, CA (United States)] [and others

    1995-07-01

    A human factors project on the use of nuclear by-product material to treat cancer using remotely operated afterloaders was undertaken by the Nuclear Regulatory Commission. The purpose of the project was to identify factors that contribute to human error in the system for remote afterloading brachytherapy (RAB). This report documents the findings from the second, third, fourth, and fifth phases of the project, which involved detailed analyses of four major aspects of the RAB system linked to human error: human-system interfaces; procedures and practices; training practices and policies; and organizational practices and policies, respectively. Findings based on these analyses provided factual and conceptual support for the final phase of this project, which identified factors leading to human error in RAB. The impact of those factors on RAB performance was then evaluated and prioritized in terms of safety significance, and alternative approaches for resolving safety significant problems were identified and evaluated.

  15. Cellular Hypertrophy and Increased Susceptibility to Spontaneous Calcium-Release of Rat Left Atrial Myocytes Due to Elevated Afterload.

    Directory of Open Access Journals (Sweden)

    Haifei Zhang

    Full Text Available Atrial remodeling due to elevated arterial pressure predisposes the heart to atrial fibrillation (AF. Although abnormal sarcoplasmic reticulum (SR function has been associated with AF, there is little information on the effects of elevated afterload on atrial Ca2+-handling. We investigated the effects of ascending aortic banding (AoB on Ca2+-handling in rat isolated atrial myocytes in comparison to age-matched sham-operated animals (Sham. Myocytes were either labelled for ryanodine receptor (RyR or loaded with fluo-3-AM and imaged by confocal microscopy. AoB myocytes were hypertrophied in comparison to Sham controls (P<0.0001. RyR labeling was localized to the z-lines and to the cell edge. There were no differences between AoB and Sham in the intensity or pattern of RyR-staining. In both AoB and Sham, electrical stimulation evoked robust SR Ca2+-release at the cell edge whereas Ca2+ transients at the cell center were much smaller. Western blotting showed a decreased L-type Ca channel expression but no significant changes in RyR or RyR phosphorylation or in expression of Na+/Ca2+ exchanger, SR Ca2+ ATPase or phospholamban. Mathematical modeling indicated that [Ca2+]i transients at the cell center were accounted for by simple centripetal diffusion of Ca2+ released at the cell edge. In contrast, caffeine (10 mM induced Ca2+ release was uniform across the cell. The caffeine-induced transient was smaller in AoB than in Sham, suggesting a reduced SR Ca2+-load in hypertrophied cells. There were no significant differences between AoB and Sham cells in the rate of Ca2+ extrusion during recovery of electrically-stimulated or caffeine-induced transients. The incidence and frequency of spontaneous Ca2+-transients following rapid-pacing (4 Hz was greater in AoB than in Sham myocytes. In conclusion, elevated afterload causes cellular hypertrophy and remodeling of atrial SR Ca2+-release.

  16. Low-Dose-Rate Californium-252 Neutron Intracavitary Afterloading Radiotherapy Combined With Conformal Radiotherapy for Treatment of Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Min [Department of Oncology, Armed Police Hospital of Hangzhou, Hangzhou, Zhejiang Province (China); Xu Hongde [Cancer Center, Armed Police Hospital of Hangzhou, Hangzhou, Zhejiang Province (China); Pan Songdan; Lin Shan; Yue Jianhua [Department of Oncology, Armed Police Hospital of Hangzhou, Hangzhou, Zhejiang Province (China); Liu Jianren, E-mail: liujianren0571@hotmail.com [Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang Province (China)

    2012-07-01

    Purpose: To study the efficacy of low-dose-rate californium-252 ({sup 252}Cf) neutron intracavitary afterloading radiotherapy (RT) combined with external pelvic RT for treatment of cervical cancer. Methods and Materials: The records of 96 patients treated for cervical cancer from 2006 to 2010 were retrospectively reviewed. For patients with tumors {<=}4 cm in diameter, external beam radiation was performed (1.8 Gy/day, five times/week) until the dose reached 20 Gy, and then {sup 252}Cf neutron intracavitary afterloading RT (once/week) was begun, and the frequency of external beam radiation was changed to four times/week. For patients with tumors >4 cm, {sup 252}Cf RT was performed one to two times before whole-pelvis external beam radiation. The tumor-eliminating dose was determined by using the depth limit of 5 mm below the mucosa as the reference point. In all patients, the total dose of the external beam radiation ranged from 46.8 to 50 Gy. For {sup 252}Cf RT, the dose delivered to point A was 6 Gy/fraction, once per week, for a total of seven times, and the total dose was 42 Gy. Results: The mean {+-} SD patient age was 54.7 {+-} 13.7 years. Six patients had disease assessed at stage IB, 13 patients had stage IIA, 49 patients had stage IIB, 3 patients had stage IIIA, 24 patients had stage IIIB, and 1 patient had stage IVA. All patients obtained complete tumor regression (CR). The mean {+-} SD time to CR was 23.5 {+-} 3.4 days. Vaginal bleeding was fully controlled in 80 patients within 1 to 8 days. The mean {+-} SD follow-up period was 27.6 {+-} 12.7 months (range, 6-48 months). Five patients died due to recurrence or metastasis. The 3-year survival and disease-free recurrence rates were 89.6% and 87.5 %, respectively. Nine patients experienced mild radiation proctitis, and 4 patients developed radiocystitis. Conclusions: Low-dose-rate {sup 252}Cf neutron RT combined with external pelvic RT is effective for treating cervical cancer, with a low incidence of

  17. Adaptive right ventricular performance in response to acutely increased afterload in a lamb model of congenital heart disease: evidence for enhanced Anrep effect.

    Science.gov (United States)

    Johnson, Rebecca C; Datar, Sanjeev A; Oishi, Peter E; Bennett, Stephen; Maki, Jun; Sun, Christine; Johengen, Michael; He, Youping; Raff, Gary W; Redington, Andrew N; Fineman, Jeffrey R

    2014-04-15

    Patients with pulmonary hypertension associated with congenital heart disease survive longer with preserved right ventricular (RV) function compared with those with primary pulmonary hypertension. The purpose of this study was to test the hypothesis that superior RV performance can be demonstrated, at baseline and when challenged with increased RV afterload, in lambs with chronic left-to-right cardiac shunts compared with control lambs. A shunt was placed between the pulmonary artery and the aorta in fetal lambs (shunt). RV pressure-volume loops were obtained 4 wk after delivery in shunt and control lambs, before and after increased afterload was applied using pulmonary artery banding (PAB). Baseline stroke volume (8.7 ± 1.8 vs. 15.8 ± 2.7 ml, P = 0.04) and cardiac index (73.0 ± 4.0 vs. 159.2 ± 25.1 ml·min(-1)·kg(-1), P = 0.02) were greater in shunts. After PAB, there was no difference in the change in cardiac index (relative to baseline) between groups; however, heart rate (HR) was greater in controls (168 ± 7.3 vs. 138 ± 6.6 beats/min, P = 0.01), and end-systolic elastance (Ees) was greater in shunts (2.63 vs. 1.31 × baseline, P = 0.02). Control lambs showed decreased mechanical efficiency (71% baseline) compared with shunts. With acute afterload challenge, both controls and shunts maintained cardiac output; however, this was via maladaptive responses in controls, while shunts maintained mechanical efficiency and increased contractility via a proposed enhanced Anrep effect-the second, slow inotropic response in the biphasic ventricular response to increased afterload, a novel finding in the RV. The mechanisms related to these physiological differences may have important therapeutic implications.

  18. Breast conserving treatment of locally advanced carcinoma T2 and T3 after neoadjuvant chemotherapy followed by quadrantectomy and high dose-rate brachytherapy, as a boost, complementary teletherapy and adjuvant chemotherapy; Tratamento conservador dos carcinomas de mama localmente avancados T2 e T3, apos quimioterapia neoadjuvante, com quadrantectomia e braquiterapia de alta taxa de dose como reforco de dose, teleterapia complementar e quimioterapia adjuvante

    Energy Technology Data Exchange (ETDEWEB)

    Fristachi, Carlos Elias [Instituto do Cancer Dr. Arnaldo Vieira de Carvalho (ICAVC), Sao Paulo, SP (Brazil). Servico de Onco-Ginecologia e Mastologia]. E-mail: cefristachi@uol.com.br; Miziara Filho, Miguel Abrao; Soares, Celia Regina; Fogaroli, Ricardo Cesar; Pelosi, Edilson Lopes; Martins, Homero Lavieri Martins [Instituto do Cancer Dr. Arnaldo Vieira de Carvalho (ICAVC), Sao Paulo, SP (Brazil). Servico de Radioterapia; Baracat, Fausto Farah [Hospital do Servidor Publico Estadual de Sao Paulo (HSPE), SP (Brazil). Servico de Ginecologia e Mastologia; Piato, Sebastiao [Irmandade da Santa Casa de Misericordia de Sao Paulo, SP (Brazil). Dept. de Obstetricia e Ginecologia (DOGI)

    2005-07-01

    Objective: to assess the treatment of breast cancer T2 and T3(T > = 4 cm), through neoadjuvant chemotherapy, quadrantectomy and high-dose-rate (HDR) brachytherapy as a boost, complementary radiotherapy and adjuvant chemotherapy, considering its method problems, its esthetics results, the aspect of local control, overall survival, and disease-free survival. Patients and method: this clinical prospective descriptive study was based on the evaluation of 26 patients ranging from 30 to 70 years old, with infiltrating ductal carcinoma, clinical stage IIB and IIIA, responsive to the neoadjuvant chemotherapy. Early and late radiotherapy complications were evaluated according to the criteria established by the RTOG/EORTC (Radiotherapy and Oncology Group /European Organization for Research and Treatment of Cancer) groups. Esthetics evaluation was done in accordance with the criteria set by a plastic surgeon. Local control was evaluated by clinical method, mammography and ultrasonography. Overall survival (OS) and the disease-free survival (DFS) were assessed according to Kaplan-Meier methodology. All the patients were treated at the Dr. Arnaldo Vieira de Carvalho Cancer Institute, from June/1995 to November/2001, and evaluated in March, 2002, with median follow-up of 28.7 months. Results: early complications were observed in 8 patients (30.6%). Two patients were classified as G3 and G4 (RTOG/EORTC). Six patients had late complications and three of them (11.5%) were classified as G3 and G4. One patient (3.8%) had local recurrence, 64 months after having local treatment. Esthetics results were considered good or regular in 16 patients (60.5%) out of 24 patients who were examined. Overall survival and disease-free survival in 24, 36 and 60 months were 100%, 92.3% and 83.1% respectively. Conclusion: early and late radiotherapy complications were considerate high when compared to literature, but esthetic results were considered acceptable. RL, OS and DFS were comparable to other

  19. [Volume and function of the right ventricle before and after intraluminal pulmonary valvuloplasty].

    Science.gov (United States)

    Rangel-Abundis, A; López, H; Badui, E; Martínez-Becerril, A

    1991-01-01

    With the purpose of studying the right ventricular infundibulum response to the obstruction of the pulmonary blood flow, the authors inform the results of the right ventricular volumes, and function changes before and after pulmonary intraluminal valvuloplasty performed in six adult patients with congenital stenosis of the pulmonary valve. After the valvuloplasty, all right ventricular volumes increased but only slightly, except for the end systolic volume at the right infundibulum, which decreased after valvuloplasty (for alpha = 0.10, p less than 0.10). The ejection fraction of this infundibulum increased after valvuloplasty (for alpha = 0.05 p less than 0.03), while the ejection fraction of the inflow chamber remained unaltered. In the same way decreased the work and power of the inflow tract of the right ventricle, regardless the decreased in the ventricular overload post-valvuloplasty; however, the ratio work vs. end diastolic volume of the right ventricle decreased (for alpha = 0.05, p less than 0.03). The authors discuss these results in relation with the changes produced by the obstruction, acute or chronic, of the pulmonary blood flow on the infundibular wall tension and contractility, whose structure and behavior allow to propose that the function of the infundibulum by means of contraction protects the pulmonary vasculature, against right ventricle hypertension.

  20. Transcutaneous Intraluminal Impedance Measurement for Minimally Invasive Monitoring of Gastric Motility: Validation in Acute Canine Models

    Directory of Open Access Journals (Sweden)

    Michael D. Poscente

    2014-01-01

    Full Text Available Transcutaneous intraluminal impedance measurement (TIIM is a new method to cutaneously measure gastric contractions by assessing the attenuation dynamics of a small oscillating voltage emitted by a battery-powered ingestible capsule retained in the stomach. In the present study, we investigated whether TIIM can reliably assess gastric motility in acute canine models. Methods. Eight mongrel dogs were randomly divided into 2 groups: half received an active TIIM pill and half received an identically sized sham capsule. After 24-hour fasting and transoral administration of the pill (active or sham, two force transducers (FT were sutured onto the antral serosa at laparotomy. After closure, three standard cutaneous electrodes were placed on the abdomen, registering the transluminally emitted voltage. Thirty-minute baseline recordings were followed by pharmacological induction of gastric contractions using neostigmine IV and another 30-minute recording. Normalized one-minute baseline and post-neostigmine gastric motility indices (GMIs were calculated and Pearson correlation coefficients (PCCs between cutaneous and FT GMIs were obtained. Statistically significant GMI PCCs were seen in both baseline and post-neostigmine states. There were no significant GMI PCCs in the sham capsule test. Further chronic animal studies of this novel long-term gastric motility measurement technique are needed before testing it on humans.

  1. Modeling of intraluminal heating of biological tissue: implications for treatment of benign prostatic hyperplasia.

    Science.gov (United States)

    Anvari, B; Rastegar, S; Motamedi, M

    1994-09-01

    A computer model for predicting the thermal response of a biological tissue to different intraluminal heating modalities is presented. A practical application of the model is to calculate the temperature distributions during thermal coagulation of prostate by contact heating and radiative heating. The model uses a two-dimensional axisymmetric diffusion approximation method to calculate the light distribution during radiative heating. The traditional Pennes' bio-heat equation is used to calculate the temperatures in the presence of blood flow. An implicit finite difference scheme with nonuniform grid spacings is used to solve the diffusion equation for light distribution and the bio-heat equation. Model results indicate that the radiative heating of prostate by Nd:YAG (1064 mm) and diode (810 mm) lasers can be a more effective and efficient means of coagulating a large volume of prostate, as compared to contact heating of the tissue. Blood perfusion is shown to provide a considerable heat sink as the laser exposure time is increased. Surface cooling by irrigation during the laser irradiation of tissue is shown to be an effective method for delaying tissue explosion and obtaining a large volume of coagulated tissue. The model also shows that the volume of the coagulated tissue is appreciably altered by a change in the rate of energy deposition.

  2. Intraluminal pressure patterns in the human colon assessed by high-resolution manometry.

    Science.gov (United States)

    Chen, Ji-Hong; Yu, Yuanjie; Yang, Zixian; Yu, Wen-Zhen; Chen, Wu Lan; Yu, Hui; Kim, Marie Jeong-Min; Huang, Min; Tan, Shiyun; Luo, Hesheng; Chen, Jianfeng; Chen, Jiande D Z; Huizinga, Jan D

    2017-02-20

    Assessment of colonic motor dysfunction is rarely done because of inadequate methodology and lack of knowledge about normal motor patterns. Here we report on elucidation of intraluminal pressure patterns using High Resolution Colonic Manometry during a baseline period and in response to a meal, in 15 patients with constipation, chronically dependent on laxatives, 5 healthy volunteers and 9 patients with minor, transient, IBS-like symptoms but no sign of constipation. Simultaneous pressure waves (SPWs) were the most prominent propulsive motor pattern, associated with gas expulsion and anal sphincter relaxation, inferred to be associated with fast propagating contractions. Isolated pressure transients occurred in most sensors, ranging in amplitude from 5-230 mmHg. Rhythmic haustral boundary pressure transients occurred at sensors about 4-5 cm apart. Synchronized haustral pressure waves, covering 3-5 cm of the colon occurred to create a characteristic intrahaustral cyclic motor pattern at 3-6 cycles/min, propagating in mixed direction. This activity abruptly alternated with erratic patterns resembling the segmentation motor pattern of the small intestine. High amplitude propagating pressure waves (HAPWs) were too rare to contribute to function assessment in most subjects. Most patients, dependent on laxatives for defecation, were able to generate normal motor patterns in response to a meal.

  3. A chemotactic gradient sequestered on endothelial heparan sulfate induces directional intraluminal crawling of neutrophils.

    Science.gov (United States)

    Massena, Sara; Christoffersson, Gustaf; Hjertström, Elina; Zcharia, Eyal; Vlodavsky, Israel; Ausmees, Nora; Rolny, Charlotte; Li, Jin-Ping; Phillipson, Mia

    2010-09-16

    During infection, chemokines sequestered on endothelium induce recruitment of circulating leukocytes into the tissue where they chemotax along chemokine gradients toward the afflicted site. The aim of this in vivo study was to determine whether a chemokine gradient was formed intravascularly and influenced intraluminal neutrophil crawling and transmigration. A chemokine gradient was induced by placing a macrophage inflammatory protein-2 (MIP-2)-containing (CXCL2) gel on the cremaster muscle of anesthetized wild-type mice or heparanase-overexpressing transgenic mice (hpa-tg) with truncated heparan sulfate (HS) side chains. Neutrophil-endothelial interactions were visualized by intravital microscopy and chemokine gradients detected by confocal microscopy. Localized extravascular chemokine release (MIP-2 gel) induced directed neutrophil crawling along a chemotactic gradient immobilized on the endothelium and accelerated their recruitment into the target tissue compared with homogeneous extravascular chemokine concentration (MIP-2 superfusion). Endothelial chemokine sequestration occurred exclusively in venules and was HS-dependent, and neutrophils in hpa-tg mice exhibited random crawling. Despite similar numbers of adherent neutrophils in hpa-tg and wild-type mice, the altered crawling in hpa-tg mice was translated into decreased number of emigrated neutrophils and ultimately decreased the ability to clear bacterial infections. In conclusion, an intravascular chemokine gradient sequestered by endothelial HS effectively directs crawling leukocytes toward transmigration loci close to the infection site.

  4. Study on intraluminal embolization with microcoils treating traumatic pseudoaneurysms in common carotid artery in rabbits

    Institute of Scientific and Technical Information of China (English)

    刘云松; 马廉亭; 吴佐泉

    2004-01-01

    Objective: To evaluate the long-term effect of endovascular occlusion with microcoils on traumatic pseudoaneurysms (TPAs) in the common carotid artery in rabbits.Methods: TPAs in the right common carotid artery were surgically made in 16 rabbits. At 3-4 weeks after operation, the survived 12 models were randomly divided into a control group (n = 3 ) with no treatment and an experimental group (n = 9), in which TPAs were intraluminally embolized with microcoils and corresponding therapy was given. Three months after embolization, the TPAs were examined with digital subtraction angiography and pathology.Results: The 3 rabbits in the control group all died of rupture of TPA. Among the 9 TPAs occluded with microcoils, 4 were completely occluded, 4 were partially occluded, and 1 was excluded due to the microcoils migrating into the parent artery. Three months after embolization, the 4 TPAs which were completely occluded remained obliterated as determined by digital subtraction angiographic findings. The parent artery remained unobstructed and the structure of the TPAs were replaced by a mass of scar tissues. The 4 TPAs which were partially occluded remained unruptured and the microcoils were compressed.Conclusions: The lumen in TPA can be completely occluded by microcoils and the parent artery is unblocked.Partial occlusion of the lumen can also prevent the rupture of TPA.

  5. Impact of poroelasticity of intraluminal thrombus on wall stress of abdominal aortic aneurysms

    Directory of Open Access Journals (Sweden)

    Polzer Stanislav

    2012-08-01

    Full Text Available Abstract Background The predictions of stress fields in Abdominal Aortic Aneurysm (AAA depend on constitutive descriptions of the aneurysm wall and the Intra-luminal Thrombus (ILT. ILT is a porous diluted structure (biphasic solid–fluid material and its impact on AAA biomechanics is controversially discussed in the literature. Specifically, pressure measurements showed that the ILT cannot protect the wall from the arterial pressure, while other (numerical and experimental studies showed that at the same time it reduces the stress in the wall. Method To explore this phenomenon further a poroelastic description of the ILT was integrated in Finite Element (FE Models of the AAA. The AAA model was loaded by a pressure step and a cyclic pressure wave and their transition into wall tension was investigated. To this end ILT’s permeability was varied within a microstructurally motivated range. Results The two-phase model verified that the ILT transmits the entire mean arterial pressure to the wall while, at the same time, it significantly reduces the stress in the wall. The predicted mean stress in the AAA wall was insensitive to the permeability of the ILT and coincided with the results of AAA models using a single-phase ILT description. Conclusion At steady state, the biphasic ILT behaves like a single-phase material in an AAA model. Consequently, computational efficient FE single-phase models, as they have been exclusively used in the past, accurately predict the wall stress in AAA models.

  6. Intraluminal pressure stimulates MAPK phosphorylation in arterioles: temporal dissociation from myogenic contractile response.

    Science.gov (United States)

    Spurrell, Brian E; Murphy, Timothy V; Hill, Michael A

    2003-10-01

    Members of the MAPK family of enzymes, p42/44 and p38, have been implicated in both the regulation of contractile function and growth responses in vascular smooth muscle. We determined whether such kinases are activated during the arteriolar myogenic response after increases in intraluminal pressure. Particular emphasis was placed on temporal aspects of activation to determine whether such phosphorylation events parallel the known time course for myogenic contraction. Experiments used single cannulated arterioles isolated from the cremaster muscle of rats with some vessels loaded with the fluorescent Ca2+-sensitive dye fura 2 (2 microM). The p42/44 inhibitor PD-98059 (50 microM) caused vasodilation but did not prevent pressure-induced myogenic constriction. The vasodilator response was accompanied by decreased smooth muscle intracellular Ca2+. Western blotting revealed a significant increase in the level of phosphorylation of p42/44 15 min after the application of a 30- to 100-mmHg pressure step. Phosphorylation of p42/44 was a late event that appeared to be temporally dissociated from contraction, which was complete within 1-5 min. EGF (80 nM) caused marked phosphorylation of p42/44 but only acted as a weak vasoconstrictor. The p38 inhibitor SB-203580 (10 microM) did not alter baseline diameter, nor did it prevent myogenic vasoconstriction. Consistent with these observations, SB-203580 did not cause a measurable change in intracellular Ca2+. The results demonstrate activation of the p42/44 class of MAPK resulting from increased transmural pressure. Such activation is, however, dissociated from the acute pressure-induced vasoconstrictor response in terms of time course and may represent the activation of compensatory, but parallel, pathways, including those related to growth and remodeling.

  7. Computed tomography angiography intraluminal filling defect is predictive of internal carotid artery free-floating thrombus

    Energy Technology Data Exchange (ETDEWEB)

    Jaberi, A.; Lum, C.; Stefanski, P.; Iancu, D. [University of Ottawa, Faculty of Medicine, Ottawa, Ontario (Canada); The Ottawa Hospital, Department of Radiology, Neuroradiology Section, Ottawa, Ontario (Canada); Thornhill, R. [Neurosciences and Clinical Epidemiology Program/Methods Centre, Ottawa Hospital Research Institute, Ottawa, Ontario (Canada); The Ottawa Hospital, Department of Radiology, Neuroradiology Section, Ottawa, Ontario (Canada); Petrcich, W. [Neurosciences and Clinical Epidemiology Program/Methods Centre, Ottawa Hospital Research Institute, Ottawa, Ontario (Canada); Momoli, F. [Children' s Hospital of Eastern Ontario Research Institute, Ottawa, Ontario (Canada); University of Ottawa, Department of Epidemiology and Community Medicine, Ottawa, Ontario (Canada); Torres, C.; Dowlatshahi, D. [University of Ottawa, Faculty of Medicine, Ottawa, Ontario (Canada); University of Ottawa, Division of Neurology, Department of Medicine, Ottawa, Ontario (Canada)

    2014-01-15

    Filling defects at the internal carotid artery (ICA) origin in the work-up of stroke or transient ischemic attack may be an ulcerated plaque or free-floating thrombus (FFT). This may be challenging to distinguish, as they can appear morphologically similar. This is an important distinction as FFT can potentially embolize distally, and its management differs. We describe a series of patients with suspected FFT and evaluate its imaging appearance, clinical features, and evolution with therapy. Between 2008 and 2013, we prospectively collected consecutive patients with proximal ICA filling defects in the axial plane surrounded by contrast on CT/MR angiography. We defined FFT as a filling defect that resolved on follow-up imaging. We assessed the cranial-caudal dimension of the filling defect and receiver operating characteristics to identify clinical and radiological variables that distinguished FFT from complex ulcerated plaque. Intraluminal filling defects were identified in 32 patients. Filling defects and resolved or decreased in 25 patients (78 %) and felt to be FFT; there was no change in 7 (22 %). Resolved defects and those that decreased in size extended more cranially than those that remained unchanged: 7.3 mm (4.2-15.9) versus 3.1 mm (2.7-3.7; p = 0.0038). Receiver operating characteristic analysis established a threshold of 3.8 mm (filling defect length), sensitivity of 88 %, specificity of 86 %, and area under the curve of 0.86 (p < 0.0001) for distinguishing FFT from plaque. Filling defects in the proximal ICA extending cranially >3.8 mm were more likely to be FFT than complex ulcerated plaque. Further studies evaluating filling defect length as a predictor for FFT are warranted. (orig.)

  8. Drug elimination function of rat small intestine: metabolism and intraluminal excretion.

    Science.gov (United States)

    Yasuhara, M; Kurosaki, Y; Kimura, T; Sezaki, H

    1984-10-15

    The metabolic and excretory function of the small intestine was investigated after oral and intravenous administration of drugs having an aromatic amino group to rats. After administration of drugs into the intestinal loop at the initial concentration of 0.1 mM, significant excretion of their N-acetylated forms into the lumen was observed. The amount of N-acetyl forms excreted in the lumen were 39.3 +/- 3.5, 63.5 +/- 20.9 and 18.0 +/- 13.8% of disappeared drugs from the lumen for p-aminobenzoic acid (PABA), p-aminosalicylic acid and sulfanilic acid, respectively. The excretion of p-acetamidobenzoic acid (Ac-PABA) after the absorption of PABA was reduced by the coadministration with salicylic acid, benzoic acid and 2,4-dinitrophenol. Salicylic acid noncompetitively inhibited the acetylation of PABA by the intestinal N-acetyltransferase. A good correlation was found between the intestinal N-acetyltransferase activities for drugs and the intraluminal excretion of N-acetyl derivatives after intestinal absorption of drugs. These results indicate that a drug having a higher susceptibility to intestinal N-acetyltransferase would undergo a greater excretion into the lumen in its N-acetyl form after intestinal absorption. After intravenous administration of PABA at a dose of 100 mumole/kg, 4.02 +/- 0.51% of dose was excreted in the lumen as Ac-PABA in 30 min. On the other hand, a significantly smaller fraction (2.72 +/- 0.68% of dose) was excreted in the lumen after intravenous injection of 100 mumole/kg of Ac-PABA. The larger excretion of Ac-PABA after administration of PABA indicates the contribution of intestinal metabolism on the transfer of PABA not only after oral, but also after intravenous administration.

  9. Clinical Report on Californium-252 Neutron Intraluminal Brachytherapy Combined with External Irradiation for Cervical Carcinoma Treatment

    Institute of Scientific and Technical Information of China (English)

    Huanyu Zhao; Keming Wang; Jian Sun; Xin Geng; Weiming Zhang

    2006-01-01

    OBJECTIVE To observe the curative effects and complications of californium-252 (252Cf) neutron intraluminal brachytherapy (IBT) combined with external irradiation (El) for treatment of cervical carcinoma.METHODS From December 2000 to December 2004, 128 cases of cervical carcinoma staged into ⅡA~ⅢB according to the International Federation of Gynecology and Obstetrics (FIGO) standards were treated with 252Cf neutron IBT using 8~10 Gy per fraction, once a week. The total dose at reference A point was 36~40 Gy in 4~5 fractions. From the second day after 252Cf neutron IBT treatment, the whole pelvic cavity was treated with 60Co γ-ray El, applying 2 Gy per fraction, 4 times per week. After 20~25 Gy of El, the center of the whole pelvic field was blocked with 4 cm of lead in width. The total dose of El was 45~50 Gy.RESULTS The short-term therapeutic effects were CR 95.3% and PR 4.7%. The 3 and 5-year local control rates were 93.5% and 87.9%. The overall 3-year survival rate was 87.5% and for Stages Ⅱ and Ⅲ , 90.9%and 81.5% respectively; the overall 5-year survival rate was 70% and for Stages Ⅱ and Ⅲ, 76.2% and 61% respectively. The rate of radiation complications was 4.7% for radiation cystitis, 7.8% for radiation proctitis, 6.3%for vagina contracture and adhesion and 5.5% for protracted radiation proctitis.CONCLUSION An combination of 252Cf neutron IBT with El for treatment of cervical carcinoma can be well-tolerated by cervical carcinoma patients. The rate of local tumor control is high and radiation complications are few.

  10. Characterization of intraluminal impedance patterns associated with gas reflux in healthy volunteers.

    Science.gov (United States)

    van Wijk, M P; Sifrim, D; Rommel, N; Benninga, M A; Davidson, G P; Omari, T I

    2009-08-01

    Multichannel intraluminal impedance (MII) recording allows assessment of flow through the oesophagus and differentiation between liquid and gas contents. Existing MII criteria for recognition of gas gastro-oesophageal reflux (GOR) have not been validated during known gas GOR in humans. (i) Characterize MII patterns of known gas GOR and optimize criteria. (ii) Clarify interrelationships between magnitude of maximal impedance change, luminal diameter and electrode-mucosa contact. Ten healthy volunteers (six male, 21-37 years) were studied using an oesophageal MII-manometry catheter. After catheter placement, subjects were asked to drink 600 mL of carbonated soft drink. Recordings were made for 20 min and the protocol repeated. Reported belches confirmed manometrically (triggered by transient lower oesophageal sphincter relaxations) were included for analysis. Those episodes were compared against commonly used criteria. Another five subjects (three male, 26-52 years) underwent simultaneous MII and videofluoroscopy using the same protocol. Videofluoroscopic images were analyzed for luminal diameter and the presence of electrode-mucosa contact. All analyzed gas GOR episodes (n = 88) were associated with a pattern of impedance rise which was either retrograde (62.5%), synchronous (19.3%) or antegrade (18.2%). Depending on the exact criteria used, sensitivity ranged from 33% to 75%. A multivariate regression model including luminal diameter and the presence of electrode-mucosa contact as independent factors accounted for 53% of all variation in impedance changes. In conclusion, a significant number of gas GOR episodes does not meet criteria for their recognition. New criteria are proposed to include specific antegrade patterns of impedance rise. Luminal diameter and the extent of contact between the oesophageal mucosa and MII-electrodes influence the magnitude and patterning of impedance change.

  11. Obligatory Role of Intraluminal O2− in Acute Endothelin-1 and Angiotensin II Signaling to Mediate Endothelial Dysfunction and MAPK Activation in Guinea-Pig Hearts

    Directory of Open Access Journals (Sweden)

    Emilia Wojtera

    2014-10-01

    Full Text Available We hypothesized that, due to a cross-talk between cytoplasmic O2−-sources and intraluminally expressed xanthine oxidase (XO, intraluminal O2− is instrumental in mediating intraluminal (endothelial dysfunction and cytosolic (p38 and ERK1/2 MAPKs phosphorylation manifestations of vascular oxidative stress induced by endothelin-1 (ET-1 and angiotensin II (AT-II. Isolated guinea-pig hearts were subjected to 10-min agonist perfusion causing a burst of an intraluminal O2−. ET-1 antagonist, tezosentan, attenuated AT-II-mediated O2−, indicating its partial ET-1 mediation. ET-1 and Ang-T (AT-II + tezosentan triggered intraluminal O2−, endothelial dysfunction, MAPKs and p47phox phosphorylation, and NADPH oxidase (Nox and XO activation. These effects were: (i prevented by blocking PKC (chelerythrine, Nox (apocynin, mitochondrial ATP-dependent K+ channel (5-HD, complex II (TTFA, and XO (allopurinol; (ii mimicked by the activation of Nox (NADH; and mitochondria (diazoxide, 3-NPA and (iii the effects by NADH were prevented by 5-HD, TTFA and chelerythrine, and those by diazoxide and 3-NPA by apocynin and chelerythrine, suggesting that the agonists coactivate Nox and mitochondria, which further amplify their activity via PKC. The effects by ET-1, Ang-T, NADH, diazoxide, and 3-NPA were opposed by blocking intraluminal O2− (SOD and XO, and were mimicked by XO activation (hypoxanthine. Apocynin, TTFA, chelerythrine, and SOD opposed the effects by hypoxanthine. In conclusion, oxidative stress by agonists involves cellular inside-out and outside-in signaling in which Nox-mitochondria-PKC system and XO mutually maintain their activities via the intraluminal O2−.

  12. Proximal pulmonary arterial obstruction decreases the time constant of the pulmonary circulation and increases right ventricular afterload.

    Science.gov (United States)

    Pagnamenta, Alberto; Vanderpool, Rebecca; Brimioulle, Serge; Naeije, Robert

    2013-06-01

    The time constant of the pulmonary circulation, or product of pulmonary vascular resistance (PVR) and compliance (Ca), called the RC-time, has been reported to remain constant over a wide range of pressures, etiologies of pulmonary hypertension, and treatments. We wondered if increased wave reflection on proximal pulmonary vascular obstruction, like in operable chronic thromboembolic pulmonary hypertension, might also decrease the RC-time and thereby increase pulse pressure and right ventricular afterload. Pulmonary hypertension of variable severity was induced either by proximal obstruction (pulmonary arterial ensnarement) or distal obstruction (microembolism) eight anesthetized dogs. Pulmonary arterial pressures (Ppa) were measured with high-fidelity micromanometer-tipped catheters, and pulmonary flow with transonic technology. Pulmonary ensnarement increased mean Ppa, PVR, and characteristic impedance, decreased Ca and the RC-time (from 0.46 ± 0.07 to 0.30 ± 0.03 s), and increased the oscillatory component of hydraulic load (Wosc/Wtot) from 25 ± 2 to 29 ± 2%. Pulmonary microembolism increased mean Ppa and PVR, with no significant change in Ca and characteristic impedance, increased RC-time from 0.53 ± 0.09 to 0.74 ± 0.05 s, and decreased Wosc/Wtot from 26 ± 2 to 13 ± 2%. Pulse pressure increased more after pulmonary ensnarement than after microembolism. Concomitant measurements with fluid-filled catheters showed the same functional differences between the two types of pulmonary hypertension, with, however, an underestimation of Wosc. We conclude that pulmonary hypertension caused by proximal vs. distal obstruction is associated with a decreased RC-time and increased pulsatile component of right ventricular hydraulic load.

  13. Tratamento cirúrgico em dois tempos do aneurisma toracoabdominal roto com prótese intraluminal sem sutura

    Directory of Open Access Journals (Sweden)

    Rodrigo de Castro BERNARDES

    1998-10-01

    Full Text Available O tratamento cirúrgico dos aneurismas toracoabominais exige toracofreno laparotomia, períodos prolongados de pinçamento aórtico com isquemia visceral, sangramento abundante de difícil controle, complicações pulmonares, renais, neurológicas e distúrbios de coagulação com morbimortalidade muitas vezes proibitiva para pacientes de idade avançada, ou portadores de distúrbios respiratórios, renais ou cardíacos prévios. A rotura aumenta em muito a já elevada taxa de morbimortalidade. Crawford (1-3 e Borst (4 descreveram operação em dois tempos para tratamento de aneurisma que atinge mais de um segmento da aorta, com bons resultados. O objetivo de nosso trabalho é mostrar a técnica cirúrgica em dois tempos, empregando prótese intraluminal sem sutura (5, 6. Esta técnica nos proporciona uma operação menos agressiva por abordar somente o segmento roto da aorta, portanto apenas uma cavidade é manipulada (tórax ou abdome. A anastomose com prótese intraluminal reduz em muito o tempo de pinçamento da aorta e, conseqüentemente, a isquemia visceral, diminuindo, também, o sangramento. A redução da agressividade cirúrgica sobre estes pacientes já gravemente enfermos nos proporcionou bons resultados cirúrgicos.The surgical management of thoracoabdominal aneurysms requires thoracophrenic laparotomy, prolonged periods of aortic clamping with visceral ischemia, profuse bleeding leading to a difficult postoperative course with pulmonary, renal, neurological complications, coagulation disturbances and others. All this resulting in an elevated morbidity/mortality very often contraindicating it for the very elderly or those with prior respiratory, renal or cardiac symptoms. Rupture of this aneurysm greatly increases the already high rate of morbidity/mortality. Crawford and Borst have described a two-stage surgery with good results, for aneurysms that affect more than one segment of aorta. The objective of our report is to demonstrate

  14. Identifying afterloading PDR and HDR brachytherapy errors using real-time fiber-coupled Al2O3:C dosimetry and a novel statistical error decision criterion

    DEFF Research Database (Denmark)

    Kertzscher, Gustavo; Andersen, Claus Erik; Siebert, Frank-André

    2011-01-01

    treatment errors, including interchanged pairs of afterloader guide tubes and 2–20mm source displacements, were monitored using a real-time fiber-coupled carbon doped aluminum oxide (Al2O3:C) crystal dosimeter that was positioned in the reconstructed tumor region. The error detection capacity was evaluated...... conditions, and (2) test a new statistical error decision concept based on full uncertainty analysis. Materials and methodsPhantom studies of two gynecological cancer PDR and one prostate cancer HDR patient treatment plans were performed using tandem ring applicators or interstitial needles. Imposed...

  15. Fluid displacement from intraluminal thrombus of abdominal aortic aneurysm as a result of uniform compression.

    Science.gov (United States)

    van Noort, Kim; Schuurmann, Richte Cl; Wermelink, Bryan; Slump, Cornelis H; Kuijpers, Karel C; de Vries, Jean-Paul Pm

    2017-01-01

    Objectives The results after aneurysm repair with an endovascular aneurysm sealing (EVAS) system are dependent on the stability of the aneurysm sac and particularly the intraluminal abdominal aortic thrombus (ILT). The postprocedural ILT volume is decreased compared with preprocedural ILT volume in aortic aneurysm patients treated with EVAS. We hypothesize that ILT is not stable in all patients and pressurization of the ILT may result in displacement of fluids from the ILT, no differently than serum is displaced from whole blood when it settles. To date, the mechanism and quantification of fluid displacement from ILT are unknown. Methods The study included 21 patients who underwent elective open abdominal aortic aneurysm repair. The ILT was harvested as a routine procedure during the operation. After excision of a histologic sample of the ILT specimen in four patients, ILT volume was measured and the ILT was compressed in a dedicated compression setup designed to apply uniform compression of 200 mmHg for 5 min. After compression, the volumes of the remaining thrombus and the displaced fluid were measured. Results The median (interquartile-range) of ILT volume before compression was 60 (66) mL, and a median of 5.7 (8.4) mL of fluid was displaced from the ILT after compression, resulting in a median thrombus volume decrease of 11% (10%). Fluid components can be up to 31% of the entire ILT volume. Histologic examination of four ILT specimens showed a reduction of the medial layer of the ILT after compression, which was the result of compression of fluid-containing canaliculi. Conclusions Applying pressure of 200 mmHg to abdominal aortic aneurysm ILT resulted in the displacement of fluid, with a large variation among patients. Fluid displacement may result in decrease of ILT volume during and after EVAS, which might have implications on pre-EVAS volume planning and on stability of the endobags during follow-up which may lead to migration, endoleak or both.

  16. Low-profile Visualized Intraluminal Support Junior Device for the Treatment of Intracranial Aneurysms

    Science.gov (United States)

    Gupta, Mihir; Cheung, Vincent J; Abraham, Peter; Wali, Arvin R; Gabel, Brandon C; Almansouri, Abdulrahman; Pannell, J. Scott; Khalessi, Alexander A

    2017-01-01

    Objective: Early case series suggest that the recently introduced Low-profile Visualized Intraluminal Support Junior (LVIS Jr.) device (MicroVention-Terumo, Inc., Tustin, CA) may be used to treat wide-necked aneurysms that would otherwise require treatment with intrasaccular devices or open surgery. We report our single-center experience utilizing LVIS Jr. to treat intracranial aneurysms involving 1.8-2.5 mm parent arteries. Methods: We retrospectively reviewed records of patients treated with the LVIS Jr. device for intracranial aneurysms at a single center. A total of 21 aneurysms were treated in 18 patients. Aneurysms were 2-25 mm in diameter; one was ruptured, while three had recurred after previous rupture and treatment. Lesions were distributed across the anterior (n=12) and posterior (n=9) circulations. Three were fusiform morphology. Results: Stent deployment was successful in 100% of cases with no immediate complications. Seventeen aneurysms were treated with stent-assisted coil embolization resulting in immediate complete occlusion in 94% of cases. Two fusiform aneurysms arising from the posterior circulation were further treated with elective clip ligation after delayed expansion and recurrence; no lesions required further endovascular treatment. Four aneurysms were treated by flow diversion with stand-alone LVIS Jr. stent, and complete occlusion was achieved in three cases. Small foci of delayed ischemic injury were noted in two patients in the setting of antiplatelet medication noncompliance. No in-stent stenosis, migration, hemorrhage, or permanent deficits were observed. Good functional outcome based on the modified Rankin Scale score (mRS ≤ 2) was achieved in 100% of cases. Conclusion: Our midterm results suggest that the LVIS Jr. stent may be used for a variety of intracranial aneurysms involving small parent arteries (1.8-2.5 mm) with complete angiographic occlusion, parent vessel preservation, and functional clinical outcomes. This off

  17. High-dose rate brachytherapy in the treatment of cancer of the cervix uteri

    Directory of Open Access Journals (Sweden)

    D. A. Aliyev

    2011-01-01

    Full Text Available Analysis of the results of examining and treating 246 patients with Stages IIA-IIIB cancer of the cervix uteri (CCU, receiving specific chemoradiotherapy (CRT at the Department of Radiotherapy, National Oncology Center (Baku, has ascertained that CRT using two high-dose (9 Gy rate brachytherapy fractions and competitive cisplatin chemotherapy is an effective, reasonably safe, and economically sound treatment method for locally advanced CCU. The method shows acceptable toxicity and may be used in routine clinical practice.

  18. Radiation therapy for localized prostate cancer. For high-dose rate conformal brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kinugawa, Keigo; Jo, Yoshimasa; Morioka, Masaaki; Tanaka, Hiroyoshi; Hiratsuka, Junichi; Imajo, Yoshinari [Kawasaki Medical School, Kurashiki, Okayama (Japan)

    1999-05-01

    Sixteen patients with localized prostate cancer were referred to our clinic for radiation therapy in combination with HDR brachytherapy using Ir-192 pellets between October 1997 and August 1998. The patients were given external beam radiation of 45 Gy to the whole pelvis in combination with an interstitial HDR brachytherapy implant of 3 fractions each delivering 5.5 Gy during two days. Using an implanting device especially designed for HDR, 10-18 applicator needles (17 gauge) were implanted into the prostate using transrectal ultrasound (TRUS) with perineal template guidance under spinal anesthesia. Pathological evaluation was performed at 6 months after treatment. This technique of external beam radiation combined with HDR brachytherapy was well tolerated. Serum prostatic antigen (PSA) levels became normalized in 87.5% of the patients (14 out of 16) within 1-14 months (median 2 months) after the irradiation. No significant intraoperative or perioperative complications occurred, however one patient (6.25%) experienced Grade 3 hematuria. Most of the early complications were otherwise Grade 1 or 2. From prospectively planned prostatic rebiopsies performed at 6 months, we can observe the radiation effects in the pathological findings such as fibrosis, basal cell hyperplasia, bizarre cells and intraductal calcifications. (K.H.)

  19. Dosimetric equivalence of non-standard high dose rate (HDR) brachytherapy catheter patterns

    CERN Document Server

    Cunha, J Adam M; Pouliot, Jean

    2009-01-01

    Purpose: To determine whether alternative HDR prostate brachytherapy catheter patterns can result in improved dose distributions while providing better access and reducing trauma. Methods: Prostate HDR brachytherapy uses a grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. On CT data from ten previously-treated patients new catheters were digitized following three catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a p...

  20. Very High Dose-Rate Radiobiology and Radiation Therapy for Lung Cancer

    Science.gov (United States)

    2015-02-01

    SLAC ) National Accelerator Laboratory. Our in-vitro studies have demonstrated a statistically significant higher cell kill with fast irradiation...between Stanford University Department of Radiation Oncology and the Accelerator Research Division at Stanford Linear Accelerator Center ( SLAC ) National...MG 10 10 s, 30 s, 3 min, and 30 min 60 MeV ( SLAC ) A549, HCT116 2, 6, 10, 12 15 min, 20 min 120 MeV ( SLAC ) For the photon irradiations, we

  1. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    CERN Document Server

    Braby, L A; Reece, W D

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation exp...

  2. Frameless high dose rate stereotactic lung radiotherapy: intrafraction tumor position and delivery time.

    Science.gov (United States)

    Peguret, Nicolas; Dahele, Max; Cuijpers, Johan P; Slotman, Ben J; Verbakel, Wilko F A R

    2013-06-01

    Intrafraction change in tumor position (Δ) was evaluated for stereotactic lung radiotherapy delivered with flattening filter free volumetric modulated arc therapy. In 140 fractions from 32 patients mean Δ (±SD) was -0.7±1.4 mm (vertical), -0.7±1.3 mm (longitudinal) and +0.2±1.2 mm (lateral) with mean vector 2.1±1.2 mm. Mean delivery time was 4.4±3.4 min (mean beam-on 1.9±0.4 min). Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Learning curve of MRI-based planning for high-dose-rate brachytherapy for prostate cancer

    DEFF Research Database (Denmark)

    Buus, Simon; Rylander, Susanne; Hokland, Steffen

    2016-01-01

    –D as treatment planning time, and D to E as treatment delivery time. Dose-volume parameters were retrieved from the dose planning system. Results from the first 21 patients were compared with the last 21 patients. Results Total procedure time, operating room time, MRI procedure time, and treatment planning time...... decreased significantly from average 7.6 to 5.3 hours (p delivery time remained unchanged at 0.5 hours. Clinical target volume prostate+3mmD90 fulfilled planning aim in 92% of procedures...

  4. Modeling of transient ionizing radiation effects in bipolar devices at high dose-rates

    Energy Technology Data Exchange (ETDEWEB)

    FJELDLY,T.A.; DENG,Y.; SHUR,M.S.; HJALMARSON,HAROLD P.; MUYSHONDT,ARNOLDO

    2000-04-25

    To optimally design circuits for operation at high intensities of ionizing radiation, and to accurately predict their a behavior under radiation, precise device models are needed that include both stationary and dynamic effects of such radiation. Depending on the type and intensity of the ionizing radiation, different degradation mechanisms, such as photoelectric effect, total dose effect, or single even upset might be dominant. In this paper, the authors consider the photoelectric effect associated with the generation of electron-hole pairs in the semiconductor. The effects of low radiation intensity on p-II diodes and bipolar junction transistors (BJTs) were described by low-injection theory in the classical paper by Wirth and Rogers. However, in BJTs compatible with modem integrated circuit technology, high-resistivity regions are often used to enhance device performance, either as a substrate or as an epitaxial layer such as the low-doped n-type collector region of the device. Using low-injection theory, the transient response of epitaxial BJTs was discussed by Florian et al., who mainly concentrated on the effects of the Hi-Lo (high doping - low doping) epilayer/substrate junction of the collector, and on geometrical effects of realistic devices. For devices with highly resistive regions, the assumption of low-level injection is often inappropriate, even at moderate radiation intensities, and a more complete theory for high-injection levels was needed. In the dynamic photocurrent model by Enlow and Alexander. p-n junctions exposed to high-intensity radiation were considered. In their work, the variation of the minority carrier lifetime with excess carrier density, and the effects of the ohmic electric field in the quasi-neutral (q-n) regions were included in a simplified manner. Later, Wunsch and Axness presented a more comprehensive model for the transient radiation response of p-n and p-i-n diode geometries. A stationary model for high-level injection in p-n junctions was developed by Isaque et al. They used a more complete ambipolar transport equation, which included the dependencies of the transport parameters (ambipolar diffusion constant, mobility, and recombination rate) on the excess minority carrier concentration. The expression used for the recombination rate was that of Shockley-Reed-Hall (SRH) recombination which is dominant for low to mid-level radiation intensities. However, at higher intensities, Auger recombination becomes important eventually dominant. The complete ambipolar transport equation including the complicated dependence of transport parameters on the radiation intensity, cannot be solved analytically. This solution is obtained for each of the regimes where a given recombination mechanism dominates, and then by joining these solutions using appropriate smoothing functions. This approach allows them to develop a BJT model accounting for the photoelectric effect of the ionizing radiation that can be implemented in SPICE.

  5. Application of RADPOS in Vivo Dosimetry for QA of High Dose Rate Brachytherapy

    DEFF Research Database (Denmark)

    Cherpak, A.; Kertzscher Schwencke, Gustavo Adolfo Vladimir; Cygler, J.

    2012-01-01

    Gy. Conclusions: In vivo dosimetry can potentially signal errors in catheter placement or numbering before entire dose is delivered. The demonstrated accuracy of RADPOS dose measurements and its ability to simultaneously measure displacement makes it a powerful tool for HDR brachytherapy treatments for prostate...... cancer, where high dose gradients and movement of the prostate gland can present unique in vivo dosimetry challenges. Financial and technical support has been received from Best Medical Canada and Ascension Technology Corporation. © 2012 American Association of Physicists in Medicine...

  6. Dose optimization of intra-operative high dose rate interstitial brachytherapy implants for soft tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Jamema Swamidas

    2009-01-01

    Full Text Available Objective : A three dimensional (3D image-based dosimetric study to quantitatively compare geometric vs. dose-point optimization in combination with graphical optimization for interstitial brachytherapy of soft tissue sarcoma (STS. Materials and Methods : Fifteen consecutive STS patients, treated with intra-operative, interstitial Brachytherapy, were enrolled in this dosimetric study. Treatment plans were generated using dose points situated at the "central plane between the catheters", "between the catheters throughout the implanted volume", at "distances perpendicular to the implant axis" and "on the surface of the target volume" Geometrically optimized plans had dose points defined between the catheters, while dose-point optimized plans had dose points defined at a plane perpendicular to the implant axis and on the target surface. Each plan was graphically optimized and compared using dose volume indices. Results : Target coverage was suboptimal with coverage index (CI = 0.67 when dose points were defined at the central plane while it was superior when the dose points were defined at the target surface (CI=0.93. The coverage of graphically optimized plans (GrO was similar to non-GrO with dose points defined on surface or perpendicular to the implant axis. A similar pattern was noticed with conformity index (0.61 vs. 0.82. GrO were more conformal and less homogeneous compared to non-GrO. Sum index was superior for dose points defined on the surface of the target and relatively inferior for plans with dose points at other locations (1.35 vs. 1.27. Conclusions : Optimization with dose points defined away from the implant plane and on target results in superior target coverage with optimal values of other indices. GrO offer better target coverage for implants with non-uniform geometry and target volume.

  7. Monte Carlo dosimetric study of the Flexisource Co-60 high dose rate source

    Science.gov (United States)

    Granero, Domingo; Perez-Calatayud, Jose; Ballester, Facundo

    2012-01-01

    Purpose Recently, a new HDR 60Co brachytherapy source, Flexisource Co-60, has been developed (Nucletron B.V. Veenendaal, The Netherlands). This study aims to obtain dosimetric data for this source for its use in clinical practice as required by AAPM and ESTRO. Material and methods Two Monte Carlo radiation transport codes were used: Penelope2008 and GEANT4. The source was centrally-positioned in a 100 cm radius water phantom. Absorbed dose and collisional kerma were obtained using 0.01 cm (close) and 0.1 cm (far) sized voxels to provide high-resolution dosimetry near (far from) the source. Dose rate distributions obtained with the two Monte Carlo codes were compared. Results and Discussion Simulations performed with those two radiation transport codes showed an agreement typically within 0.2% for r > 0.8 cm and up to 2% closer to the source. Detailed results of dose distributions are being made available. Conclusions Dosimetric data are provided for the new Flexisource Co-60 source. These data are meant to be used in treatment planning systems in clinical practice. PMID:23346138

  8. Targeting MRS-Defined Dominant Intraprostatic Lesions with Inverse-Planned High Dose Rate Brachytherapy. Addendum

    Science.gov (United States)

    2009-06-01

    compromising the dose coverage of the prostate and the protection to the urethra , rectum, and bladder for prostate cancer patients treated with High...fusion, dose escalation, prostate cancer 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF...18 4 INTRODUCTION Research Project Description Men with prostate cancer , in particular those with advanced

  9. Catheter-based intraluminal optical coherence tomography (OCT) of the ureter: ex-vivo correlation with histology in porcine specimens

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Lisse, Ulrike L.; Stief, Christian G. [University of Munich, Department of Urology, Munich (Germany); Meissner, Oliver A.; Bauer, Margit; Eibel, Roger; Reiser, Maximilian F.; Mueller-Lisse, Ullrich G. [University of Munich, Department of Radiology, Munich (Germany); Babaryka, Gregor [University of Munich, Department Pathology, Munich (Germany)

    2006-10-15

    Intraluminal optical coherence tomography (OCT) applies coherent light to provide cross-sectional images with a spatial resolution of 10-25 {mu}m. We compared OCT and matching whole-mount histology microscopy sections of porcine upper ureters ex vivo for visualization and delineation of different tissue layers of the ureteral wall. Porcine ureters (six specimens, 24 quadrants) were flushed with normal saline solution prior to insertion of the OCT catheter (diameter, 0.014 inch, OCT wavelength, 1,300{+-}20 nm). Cross-sectional OCT images were obtained in marked locations before specimens were fixed in 4% formalin, cut at marked locations, whole-mounted, and stained with hematoxilin and eosin. Visualization and delineation of different tissue layers of the ureteral wall by OCT was compared with matching histology by two independent observers (O1,O2). OCT distinguished tissue layers of the ureteral wall in all quadrants. In OCT images, O1/O2 delineated urothelium and lamina propria in 23/24 quadrants, lamina propria and muscle layer in 19/16 quadrants, inner and outer muscle layer in 13/0 quadrants, and urothelial cell layers in 13/2 quadrants, respectively. Intraluminal OCT provides histology-like images of the ureter in porcine specimens ex vivo and reliably distinguishes between urothelium and deeper tissue layers of the ureteral wall. (orig.)

  10. [A CASE OF ASCENDING COLON CANCER RECURRENCE WITH INTRALUMINAL URETERAL DISSEMINATION MIMICKING PRIMARY URETERAL CANCER, DETECTED DURING INVESTIGATION FOR FEVER].

    Science.gov (United States)

    Nishiyama, Ryuichi; Kubota, Masashi; Kanno, Toru; Okada, Takashi; Higashi, Yoshihito; Yamada, Hitoshi

    2015-10-01

    A 69-year-old woman visited our hospital with a chief complaint of fever. Five years ago, she was diagnosed as ascending colon cancer and received right hemi-colectomy. One year later, local recurrence with right hydronephrosis was detected, and she received chemotherapy -4 cycles of modified fluorouracil, leucovorin, and oxaliplatin (mFOLFOX6) plus bevacizumab, and 12 cycles of fluorouracil, leucovorin, and irinotecan (FOLFIRI) plus bevacizumab- for two years. Local recurrence and right hydronephrosis disappeared on positron emission tomography performed 4 years postoperatively. This time, abdominal computed tomography for investigation of fever showed a relapse of right hydronephrosis and pyonephrosis. Cystoscopy revealed non-papillary tumor from the right ureteral orifice. Pelvic magnetic resonance imaging showed multiple tumors in the right ureter, and the distal lesion projecting into the bladder. After the general condition became well by right nephrostomy for infection control, transurethral resection of bladder tumor was performed. Histological examination of the specimen revealed a metastatic tubular adenocarcinoma (colon origin). Although right nephrectomy was performed for pyonephrosis control, she died of local progression of ascending colon cancer 10 months after first visit. Intraluminal ureteral progression of carcinoma originating from organs other than urinary tract is very rare. To our knowledge, this is the 9th report in the English or Japanese literature. In this case we could not rule out primary ureteral cancer preoperatively, and histological examination revealed intraluminal ureteral dissemination of ascending colon cancer.

  11. Treatment of malignant digestive tract obstruction by combined intraluminal stent installation and intra-arterial drug infusion

    Institute of Scientific and Technical Information of China (English)

    Ai-Wu Mao; Zhong-Du Gao; Jia-Yu Xu; Ren-Jie Yancg; Xiang-Seng Xiao; Ting-Hui Jiang; Wei-Jun Jiang

    2001-01-01

    AIM To study the palliative treatment of malignant obstrution of digestive tract with placement of intraluminal stent combined with intra-arterial infusion of chemotherapeutic drugs. METHODS A total of 281 cases of digestive tract malignant obstruction were given per oral (esophagus,stomach, duodenum and jejunum), per anal (colon and rectum ) and percutaneous transhepatic ( biliary )installation of metallic stent. Among them, 205 cases received drug infusion by cannulation of tumor supplying artery with Seldingers technique. RESULTS Altogether 350 stents were installed in 281 cases, obstructive symptoms were relieved or ameliorated after installation. Occurrence of restenotic obstruction was 8 - 43 weeks among those with intraarterial drug infusion, which was later than 4 - 26 weeks in the group with only stent installation. The average survival time of the former group was 43 (3 - 105) weeks,which was significantly longer than 15 (3- 24) weeks of the latter group. CONCLUSION Intraluminal placement of stent combined with intra-arterial infusion chemotherapy is one of the effective palliative therapies for malignant obstruction of the digestive tract with symptomatic as well as etiological treatment.

  12. Experience in the safety use of a brachytherapy by manual afterloading; Experiencia en el uso seguro de un sistema de braquiterapia por carga diferida manual

    Energy Technology Data Exchange (ETDEWEB)

    Marco Hernandez, Jose M.; Flores Caro, Jorge; Morales Jorge, Leonel [Instituto Nacional de Oncologia y Radiobiologia, La Habana (Cuba). Seccion de Proteccion Radiologica

    2001-07-01

    Early in the twenty century started in Cuba the use of Radium Brachytherapy for malign neoplasms of the uterine cervix and endometrium, using the Manchester system. This became the main source of personal collective dose and unwanted radiological incidents. In 1989 this method was substituted by Amersham 137 Cs manual afterloading system. The purpose of this work has been to evaluate the impact of the new system in the optimization of this practice in the effective dose and collective effective dose distributions, during ten years, comparing these results of both systems and sources. Monitoring of personnel was done using film bages and recently by means of TLD(Li Fl:Mg). Highest annual exposures with 137 Cs reached only once to 26,2 mSv as result of local rules violation. Technologists, nurses and ward service personnel recorded 14%, 11%, and 29% of the ICRP annual effective dose limit. Thanks to the afterloading system, organisative rules and use of shielded containers, it was achieved a 79% reduction in the collective effective dose. (author)

  13. Bronchoscopic treatment of patients with intraluminal microinvasive radiographically occult lung cancer not eligible for surgical resection: a follow-up study.

    NARCIS (Netherlands)

    Vonk Noordegraaf, A.; Postmus, P.E.; Sutedja, G.

    2003-01-01

    or=1 cm in size, intraluminally located in the central airways, with no bronchial wall invasion or extraluminal tumor growth on high resolution CT (HRCT), with visible distal margin under conventional and autofluorescence bronchoscopy (AFB). BT was given with curative intent and consecutive patients

  14. Magnetic resonance imaging of the intraluminal thrombus in abdominal aortic aneurysms. A quantitative and qualitative evaluation and correlation with growth rate

    DEFF Research Database (Denmark)

    Behr-Rasmussen, Carsten; Gammelgaard, Lise; Fründ, Ernst T

    2017-01-01

    BACKGROUND: The role of the intraluminal thrombus (ILT) in abdominal aortic aneurysm (AAA) growth remains incompletely understood. MRI is superior to other methods in depicting the morphology of the ILT. This study brings preliminary, but novel information on the presence and morphological charac...

  15. Multi-Detector CT Findings of the Normal Appendix in Children: Evaluation of the Position, Diameter, and Presence or Absence of Intraluminal Gas

    Energy Technology Data Exchange (ETDEWEB)

    Park, Woon Ju; Kim, Jong Chul [Dept. of Radiology, Chungnam National University College of Medicine, Daejeon (Korea, Republic of)

    2011-08-15

    To assess the usefulness of multi-detector CT (MDCT) with multiplanar reformations (MPR) for the evaluation of the position, diameter and presence or absence of intraluminal gas in the normal appendix in children. From 2007 to 2010, we retrospectively analyzed the MDCT images of normal appendices in 133 children, and evaluated the position, diameter, and presence or absence of intraluminal gas in the appendix. Among the 133 appendices, type I (postileal and medial paracecal position) was found in 64 children, type II (subcecal position) in 22, type III (retrocecal and retrocolic/laterocolic position) in 15, type IV (preileal and medial colic position) in 16, and type V (lower pelvic position) in 16 children. The mean diameter was 5.8 mm {+-} 1.2 (SD) (range; 3.2-8.7 mm). There was a high correlation between the appendiceal diameter and age (p = 0.000).There was no statistically significant difference in the appendiceal diameter between boys and girls (p = 0.470). Intraluminal gas was found in 115 appendices and there was no statistically significant correlation between the appendiceal diameter and intraluminal gas (p = 0.502). The MDCT with MPR was useful for the evaluation of the normal appendices in children. The procedure may be useful for the diagnosis of equivocal or unusual appendicitis in children.

  16. Avaliação da resposta bioquímica no câncer inicial de próstata: experiência uninstitucional comparando teleterapia exclusiva ou associada à braquiterapia de alta taxa de dose Evaluation of biochemical response on early prostate cancer: comparison between treatment with external beam radiation alone and in combination with high-dose rate conformal brachytherapy boost

    Directory of Open Access Journals (Sweden)

    Douglas Guedes de Castro

    2004-08-01

    biochemical response in patients with locally advanced prostate cancer treated with external beam radiation therapy alone or in combination with conformal brachytherapy boost. MATERIALS AND METHODS: From November 1997 to January 2000, 74 patients received 45 Gy of pelvic external irradiation and four were treated with high dose rate iridium-192 conformal boost implants of 4 Gy each (BT. These were compared with 29 other patients treated with 45 Gy of pelvic external irradiation followed by a 24 Gy of bilateral ARC boost (RT from October 1996 to February 2000. Some patients received neoadjuvant androgen deprivation therapy. Three-year actuarial biochemical control rates (BC3 and pretreatment biochemical response predictors such as prostate-specific antigen pretreatment (PSAi, Gleason score (GS and clinical stage (CS, were evaluated. RESULTS: Median follow-up was of 25 months for the RT group and 37 months for the BT group. BC3 was 51% versus 73% (p = 0.032 for RT and BT, respectively. Comparisons of biochemical control by treatment group stratified by PSAi showed that BC3 for RT versus BT was 85.7% versus 79.1% (p = 0.76 for PSAi 10 ng/mL, respectively. For patients with GS 6, BC3 was 78% versus 55% (p = 0.58 for RT versus BT, respectively. For patients with CS T2a, BC3 was 73% versus 69% (p = 0.692 for RT versus BT, respectively. The relative risk of biochemical relapse was 2.3 (95% IC: 1.0-5.1 for patients in RT group compared to the BT group. When adjusted for PSAi and GS, the relative risk of biochemical relapse was 2.4 (95% IC: 1.0-5.7. CONCLUSION: The treatment modality was an independent prognostic factor for biochemical relapse, with a significant improvement in the biochemical control with BT. These early results suggest that this treatment was most beneficial in patients with PSAi > 10 ng/mL, CS < T2a and GS < 6.

  17. [Evaluation of the tolerance and efficiency of quinfamide, a new intraluminal amebicide, in man (one day treatment). Double blind study].

    Science.gov (United States)

    Guevara, L

    1980-01-01

    A new intraluminal amebicide (Quinfamide) was tested to assess its effectivity and tolerance for treatment of non-dysenteric intestinal amebiasis. The drug was administered to three groups of ten patients each, whom received 300, 600 and 1 200 mg. on a 24 hours schedule. Another group of ten patients received Teclozan as control drug. Diagnosis and results were judged by rectosigmoidoscopy before, 15 and 30 days after treatment. In addition, microscopic investigation of ameba was performed in freshly passed stools, before, and after 8, 15 and 30 days of treatment. Success after treatment with the three doses of Quinfamide was obtained in 89.2% of the cases. Side reactions were clinically non-significant. More experience is needed before the effectivity of the drug is stablished.

  18. Double Endoscopic Intraluminal Operation (DEILO) for Early Gastric Cancer: Outcome of Novel Procedure for Endoscopic Submucosal Dissection.

    Science.gov (United States)

    Ogata, Kyoichi; Yanai, Mitsuhiro; Kuriyama, Kengo; Suzuki, Masaki; Yanoma, Toru; Kimura, Akiharu; Kogure, Norimichi; Toyomasu, Yoshitaka; Ohno, Tetsuro; Mochiki, Erito; Kuwano, Hiroyuki

    2017-01-01

    Endoscopic submucosal dissection (ESD) has been used to treat patients with early gastric cancer (EGC). Although several endoscopic devices have been developed to ensure easy and safe ESD, this technique still requires an experienced, highly skilled endoscopist, as it is performed through a single gastroscope, thus requiring one-handed surgical techniques. To overcome these limitations, many ESD procedures with counter-traction have been developed, such as the double scope, double channel scope, clip with line, magnetic anchor, percutaneous traction and external grasping forceps methods. We devised a double endoscopic intraluminal operation (DEILO). Two endoscopes were simultaneously inserted into the stomach. One endoscope was used to lift the lesion, and the other was used to excise the lesion. The DEILO procedure was performed on 122 cases of EGC. In this article, we report the efficacy and safety of DEILO in patients with EGC.

  19. Onze anos de experiência com emprego do anel intraluminal para tratamento das doenças da aorta

    Directory of Open Access Journals (Sweden)

    BERNARDES Rodrigo de Castro

    1999-01-01

    Full Text Available O tratamento cirúrgico das doenças da aorta é geralmente acompanhado de altas taxas de morbimortalidade. O paciente que tem média de idade avançada geralmente é apresentado ao cirurgião em estado grave, com má condição nutricional, muitas vezes com alterações em vários órgãos e sistemas causados pela própria doença aguda. A correção convencional exige técnicas coadjuvantes complexas e agressivas como a circulação extracorpórea prolongada, hipotermia profunda, parada circulatória total além de prolongados tempos de pinçamento de aorta. Na tentativa de reduzir a agressão cirúrgica no paciente já intensamente debilitado pela própria doença, desenvolvemos, em 1988, um anel intraluminal (1, 2 que tem medidas projetadas e experimentadas para facilitar a sua manipulação e anastomose, proporcionando uma diminuição acentuada no tempo de operação, tempo de CEC, tempo de pinçamento de aorta, excluindo muitas vezes a circulação extracorpórea e a hipotermia, obtendo uma anastomose fácil, rápida, segura e hemostática. Entre março de 1988 e janeiro de 1999, 432 pacientes foram submetidos a tratamento cirúrgico de dissecções ou aneurismas da aorta em nosso Serviço. Em 328 pacientes empregamos o anel intraluminal como técnica de anastomose. Usamos 489 anéis. Cento e vinte e cinco pacientes eram portadores de dissecção aguda de aorta do tipo A, 29 eram portadores de dissecção aguda de aorta do tipo B, 81 de aneurisma de aorta ascendente, 8 de aneurisma de arco aórtico, 28 pacientes eram portadores de aneurisma de aorta torácica descendente, 17 eram portadores de aneurisma toracoabdominal e 40 pacientes de aneurisma de aorta abdominal infra-renal. A mortalidade global foi de 13,41%. O seguimento ambulatorial destes pacientes variou de 11 anos a 25 dias. A curva actuarial de sobrevivência em 11 anos mostra 67,3%. Em nenhum caso observamos as complicações descritas na literatura, como embolia, formação de

  20. Non-Contrast-Enhanced Silent Scan MR Angiography of Intracranial Anterior Circulation Aneurysms Treated with a Low-Profile Visualized Intraluminal Support Device.

    Science.gov (United States)

    Takano, N; Suzuki, M; Irie, R; Yamamoto, M; Teranishi, K; Yatomi, K; Hamasaki, N; Kumamaru, K K; Hori, M; Oishi, H; Aoki, S

    2017-08-01

    The Low-Profile Visualized Intraluminal Support Device comprises a small-cell nitinol structure and a single-wire braided stent that provides greater metal coverage than previously reported intracranial stents, as well as assumed strong susceptibility artifacts. This study aimed to assess the benefits of non-contrast-enhanced MRA by using a Silent Scan (Silent MRA) for intracranial anterior circulation aneurysms treated with Low-Profile Visualized Intraluminal Support Device stents. Thirty-one aneurysms treated with Low-Profile Visualized Intraluminal Support Device stents were assessed by using Silent MRA, 3D TOF-MRA, and x-ray DSA. The quality of MRA visualization of the reconstructed artery was graded on a 4-point scale from 1 (not visible) to 4 (excellent). Aneurysm occlusion status was evaluated by using a 2-grade scale (total occlusion/remnant [neck or aneurysm]). Weighted κ statistics were used to evaluate interobserver and intermodality agreement. The mean scores ± SDs for Silent MRA and 3D TOF-MRA were 3.16 ± 0.79 and 1.48 ± 0.67 (P < .05), respectively, with substantial interobserver agreement (κ = 0.66). The aneurysm occlusion rates of the 2-grade scale (total occlusion/remnant [neck or aneurysm]) were 69%/31% for DSA, 65%/35% for Silent MRA, and 92%/8% for 3D TOF-MRA, respectively. The intermodality agreements were 0.88 and 0.30 for DSA/Silent MRA and DSA/3D TOF-MRA, respectively. Silent MRA seems to be useful for visualizing intracranial anterior circulation aneurysms treated with Low-Profile Visualized Intraluminal Support Device stents. © 2017 by American Journal of Neuroradiology.

  1. High-quality conforming hexahedral meshes of patient-specific abdominal aortic aneurysms including their intraluminal thrombi.

    Science.gov (United States)

    Tarjuelo-Gutierrez, J; Rodriguez-Vila, B; Pierce, D M; Fastl, T E; Verbrugghe, P; Fourneau, I; Maleux, G; Herijgers, P; Holzapfel, G A; Gomez, E J

    2014-02-01

    In order to perform finite element (FE) analyses of patient-specific abdominal aortic aneurysms, geometries derived from medical images must be meshed with suitable elements. We propose a semi-automatic method for generating conforming hexahedral meshes directly from contours segmented from medical images. Magnetic resonance images are generated using a protocol developed to give the abdominal aorta high contrast against the surrounding soft tissue. These data allow us to distinguish between the different structures of interest. We build novel quadrilateral meshes for each surface of the sectioned geometry and generate conforming hexahedral meshes by combining the quadrilateral meshes. The three-layered morphology of both the arterial wall and thrombus is incorporated using parameters determined from experiments. We demonstrate the quality of our patient-specific meshes using the element Scaled Jacobian. The method efficiently generates high-quality elements suitable for FE analysis, even in the bifurcation region of the aorta into the iliac arteries. For example, hexahedral meshes of up to 125,000 elements are generated in less than 130 s, with 94.8 % of elements well suited for FE analysis. We provide novel input for simulations by independently meshing both the arterial wall and intraluminal thrombus of the aneurysm, and their respective layered morphologies.

  2. An integrated fluid-chemical model towards modeling the formation of intra-luminal thrombus in abdominal aortic aneurysms

    Directory of Open Access Journals (Sweden)

    Jacopo eBiasetti

    2012-07-01

    Full Text Available Abdominal Aortic Aneurysms (AAAs are frequently characterized by the presenceof an Intra-Luminal Thrombus (ILT known to influence biochemically and biomechanicallytheir evolution. ILT progression mechanism is still unclear and little is known regardingthe impact on this mechanism of the chemical species transported by blood flow.Chemical agonists and antagonists of platelets activation, aggregation, and adhesion andthe proteins involved in the coagulation cascade (CC may play an important role in ILTdevelopment. Starting from this assumption, the evolution of chemical species involvedin the CC, their relation to coherent vortical structures (VSs and their possible effect onILT evolution have been studied. To this end a fluido-chemical model that simulates theCC through a series of convection-diffusion-reaction (CDR equations has been developed.The model involves plasma-phase and surface bound enzymes and zymogens, and includesboth plasma-phase and membrane-phase reactions. Blood is modeled as a non-Newtonianincompressible fluid. VSs convect thrombin in the domain and lead to the high concentration observed in the distal portion of the AAA. This finding is in line with the clinicalobservations showing that the thickest ILT is usually seen in the distal AAA region. Theproposed model, due to its ability to couple the fluid and chemical domains, provides anintegrated mechanochemical picture that potentially could help unveil mechanisms of ILTformation and development.

  3. Inter- and intraobserver agreement in 24-hour combined multiple intraluminal impedance and pH measurement in children.

    Science.gov (United States)

    Pilic, Denisa; Höfs, Carolin; Weitmann, Sandra; Nöh, Frank; Fröhlich, Thorsten; Skopnik, Heino; Köhler, Henrik; Wenzl, Tobias G; Schmidt-Choudhury, Anjona

    2011-09-01

    Assessment of intra- and interobserver agreement in multiple intraluminal impedance (MII) measurement between investigators from different institutions. Twenty-four 18- to 24-hour MII tracings were randomly chosen from 4 different institutions (6 per center). Software-aided automatic analysis was performed. Each result was validated by 2 independent investigators from the 4 different centers (4 investigator combinations). For intraobserver agreement, 6 measurements were analyzed twice by the same investigator. Agreement between investigators was calculated using the Cohen kappa coefficient. Interobserver agreement: 13 measurements showed a perfect agreement (kappa > 0.8); 9 had a substantial (kappa 0.61-0.8), 1 a moderate (kappa coefficient 0.41 to 0.6), and 1 a fair agreement (kappa coefficient 0.11-0.4). Median kappa value was 0.83. Intraobserver agreement: 5 tracings showed perfect and 1 showed a substantial agreement. The median kappa value was 0.88. Most measurements showed substantial to perfect intra- and interobserver agreement. Still, we found a few outliers presumably caused by poorer signal quality in some tracings rather than being observer dependent. An improvement of analysis results may be achieved by using a standard analysis protocol, a standardized method for judging tracing quality, better training options for method users, and more interaction between investigators from different institutions.

  4. Resultados a médio prazo do tratamento cirúrgico da dissecção aguda de aorta tipo A com o emprego da prótese intraluminal Surgical treatment of type a aortic dissection using intraluminal prosthesis medium term follow up

    Directory of Open Access Journals (Sweden)

    Jefferson Francisco de OLIVEIRA

    2001-06-01

    Full Text Available Introdução: O conceito de prótese intraluminal foi introduzido por CARREL, em 1912. Em 1978, DUREAU & ABLASA descreveram os primeiros casos de dissecção aguda de aorta tratados com o emprego da prótese intraluminal. Esta prótese foi utilizada nos anos 80 por vários grupos com bons resultados. Vários relatos de complicações (migração, embolias, estenoses, formação de pseudo-aneurismas fizeram com que os grupos cirúrgicos perdessem o entusiasmo por esta técnica. Objetivo: Avaliar a anastomose empregando a prótese intraluminal sem sutura no tratamento da dissecção aguda de aorta tipo A. Casuística e Métodos: Sessenta e quatro pacientes com diagnóstico de dissecção aguda de aorta do tipo A foram operados em nosso Serviço. Em todos os casos empregamos o anel intraluminal como técnica de sutura. A idade média dos pacientes era de 56,3 anos, sendo 57 (89% do sexo masculino. Todos os pacientes eram portadores de hipertensão arterial sistêmica. Em 26 pacientes utilizamos somente a anastomose intraluminal, com o anel proximal acima dos óstios coronários de modo a ressuspender a valva aórtica e o anel distal posicionado junto à origem do tronco braquiocefálico. O tempo médio de pinçamento da aorta nestes pacientes foi de 9 minutos e o tempo médio de CEC de 26 minutos. Somente em 1 caso houve rotura da ligadura sobre o anel proximal, quando realizamos uma operação radical (Bentall- DeBonno, mantendo o anel distal. Em 23 pacientes utilizamos a ressuspensão da valva aórtica e o preparo da raiz da aorta com duplo retalho de Dacron, empregando o anel intraluminal na anastomose distal. Abordamos o arco aórtico em 8 pacientes. A troca da valva aórtica foi necessária em apenas 6 pacientes. A mortalidade global foi de 10,3%, sendo que nos pacientes onde foi possível o tratamento com o duplo anel não houve nenhum óbito. Na avaliação pós-operatória destes pacientes foi realizado ecocardiograma e aortografia. N

  5. Treatment of extensive carcinoma of the cervix with the transperineal parametrial butterfly. [Dosimetry efficiency and complications of afterloaded /sup 192/Ir implants

    Energy Technology Data Exchange (ETDEWEB)

    Feder, B.H.; Nisar Syed, A.M.; Neblett, D.

    1978-01-01

    In advanced carcinoma of the cervix the associated obliteration of the fornices or contracture of the vagina may interfere with accurate placement of conventional intracavitary applicators. Poorly placed applicators fail to irradiate the pelvis homogeneously. Waterman (and others) solved this dilemma by transvaginal radium implants many years ago; however, despite good survival figures, this technique has not gained popularity, presumably because of excessive exposure to personnel. In this paper, we describe a technique which largely eliminates the exposure problem and at the same time improves the homogeneity of pelvic endoradiotherapy. We locate what is in essence a pair of paravaginal interstitial colpostats in both parametria in combination with the usual intrauterine tandem. This helps to distribute the dose laterally, with relative sparing of bladder and rectum. The technique employs a template to guide the insertion into the parametria of a group of 18 gauge hollow steel needles transperineally. Afterloading with /sup 192/Ir is accomplished when the patient has returned to her room (after orthogonal radiography and computer dosimetry). Doses to point B compare very favorably to those at point A.

  6. 64-element intraluminal ultrasound cylindrical phased array for transesophageal thermal ablation under fast MR temperature mapping: an ex vivo study.

    Science.gov (United States)

    Melodelima, D; Salomir, R; Mougenot, C; Moonen, C; Cathignol, D

    2006-08-01

    This work was undertaken to investigate the feasibility of using a cylindrical phased array for transoesophaeal thermal ablation under magnetic resonance (MR) imaging guidance. Sixty-four transducers (0.45 mm wide by 15 mm tall), operating at 4.6 MHz, were spread around the periphery of a 10.6-mm-diam cylinder. The head of the applicator was covered with a 65-microm thick latex balloon attached using watertight seals. This envelope was inflated with degassed water to provide acoustic coupling between the transducer and the tissues. The underlying operating principle of this applicator is to rotate a plane ultrasound beam electronically. For this purpose, eight adjacent transducers were excited with appropriate delay times so as to generate a plane wave. The exposure direction was changed by exciting a different set of eight elements. Ex vivo experiments conducted on 47 samples of pig liver under MR temperature monitoring demonstrated the ability of this applicator to generate cylindrical or sector-based coagulation necroses at depths up to 19 mm with excellent angular precision by applying 20 W/cm2. MR thermometry was performed in "real-time" with segmented echo-planar imaging gradient echo sequences. The temporal resolution was approximately 3 s/ image. The average value for the temperature baseline in liver tissue close to the applicator was 0.3 degrees C (+/- 0.6 degrees C). The thermal dose delivered in tissues was computed on-line during temperature imaging. Excellent MR compatibility was demonstrated, all MR acquisitions were performed without susceptibility artifacts or radio-frequency interferences with the ultrasound device. Thermal lesions identified on post-treatment follow up showed good correlation with online MR thermometry data. The individual differences between measurements performed visually and using MRI thermal dose maps were about 11% of volume. This study demonstrated the feasibility of thermal ablation using a phased array intraluminal

  7. Effects of luminal nutrient absorption, intraluminal physical stimulation, and intravenous parenteral alimentation on the recovery responses of duodenal villus morphology following feed withdrawal in chickens.

    Science.gov (United States)

    Tarachai, P; Yamauchi, K

    2000-11-01

    The aim of this study was to clarify which of the following three factors induces villus morphological recovery best: enteral nutrient absorption, intraluminal physical stimulation, or intravenous parenteral alimentation. At 142 d, male White Leghorn chickens (Gallus gallus domesticus) were divided into eight groups of five birds each as follows: 1) access given ad libitum to a commercial layer mash diet (CP, 17.5%; ME, 2,830 kcal/kg) (control), 2) 5-d feed withdrawal (feed withdrawal), 3) 3-d feed withdrawal (3-FW), followed by refeeding the same diet as the control for 2 d (refeeding), 4) 3-FW followed by force-feeding enteral hyperalimentation (enteral), 5) 3-FW followed by force-feeding an indigestible (nonabsorbable) substance (kaolin), 6) 3-FW followed by force-feeding water for 2 d (force-fed control), 7) 3-FW followed by parenteral hyperalimentation (parenteral), and 8) 3-FW followed by no alimentation (sham control) for 2 d. In the refeeding and enteral groups, BW significantly recovered (P kaolin could not be absorbed enterally. Compared with the feed withdrawal group, villus height, cell mitosis, and villus tip surface morphology of refeeding and enteral groups exhibited rapid villus morphological recovery. Villus morphological recovery of the enteral group appears to have been caused by enteral nutrient absorption. However, villus morphology in the kaolin treatment was not different from that in the feed withdrawal group, which suggests that intraluminal physical stimulation had no effect on villus morphological recovery. On the other hand, the parenteral group showed no effect on villus morphological recovery, which suggests that the parenteral nutrient supplied to the villi via the blood could not induce villus morphological recovery; the intestinal mucosal atrophy might have been caused by the absence of enteral nutrients, and would only be stimulated by enteral nutrient absorption. In conclusion, the present findings suggest that villus morphology

  8. Methods on Quality Assurance of γ-ray Source of Afterloading Devices%γ射线后装治疗辐射源的质量保证方法

    Institute of Scientific and Technical Information of China (English)

    张庆钊; 曹小龙; 陈梅芬; 黄颂钊; 胡家柱

    2012-01-01

    获得准确的源强度是表面敷贴放疗剂量与体内治疗剂量计算的基础.在国外,美国医学物理学会( AAPM)制定有直观的放射源校准规程——《在空气中校准》.该方法比较合理、准确、可靠,但是散射修正比较复杂.我国也有国家制定的《192Ir源活度校准规程》,它与AAPM推荐的校准方法的最大区别在于它是在水中校准.事实上,在国内很少有医院对后装192Ir源外观活度进行校准.本文探讨用外照射的小水箱来测量后装放射源活度的方法,测量的结果说明了源活度是基本准确的,符合国家校准规程要求.%Obtaining accurate apparent activity of source is the base stone of the dose calculation of surface applicator brachytherapy and interstitial and intracavitary brachytherapy. There are explicit protocols for source calibration in AAPM that is source calibration in-air. And this way is more reasonable, veracity and reliable, however, the correction of scatter from all surfaces in the room is complicate. There is a protocol of calibrations for apparent activity of afterloading iridium-192 source in our country. The most different is that it is calibrated in-water phantom, there are little hospitals calibrating the apparent activity of afterloading iridium-192 according to this protocol .The paper discussed the method of measuring afterloading radiation source activity with small water phantom. The result demonstrates the apparent activity of afterloading iridium-192 source is veracity.

  9. Three-dimensional dosimetry of the full and empty bladder in high dose rate vaginal cuff brachytherapy.

    Science.gov (United States)

    Kobzda, Justyna D; Cikowska-Wozniak, Ewa; Michalska, Magdalena; Makarewicz, Roman

    2014-06-01

    The objectives of the study were to assess the bladder doses during vaginal cuff brachytherapy and to examine the effect of bladder filling on normal tissue dosimetry by means of computed tomography. A total number of 45 women were enrolled in a prospective clinical trial. Patients were treated with the application of a single-line source vaginal cylinder. All the patients were asked to consume 400 mL of water 40 minutes before computed tomography scans were taken. For each patient, 2 treatment plans were performed-one with full bladder and the other one when the bladder was emptied. A dose-volume histogram and the equivalent of 2-Gy dose for full and empty bladder were calculated. Doses to the bowels in 2 states of the bladder were estimated. Thirty-five patients received a lower dose to the empty bladder than to the filled organ. The average dose difference was 0.5 Gy. Ten patients received a lower dose to the full bladder than to the empty one. However, in this case, the difference amounted only to 0.2 Gy on average. Dose parameters (the maximal dose received by 0.1 cm of tissue and the maximal dose received by 2 cm of tissue) were lower in the empty state, but the volumetric parameters (the percent of bladder volume receiving ≥50% of the prescribed dose and the percent of bladder volume receiving ≥80% of the prescribed dose) were higher in the empty state of the bladder. Doses to the bowels seemed to be higher in the empty bladder. However, none of the doses exceeded the limitations. The results have shown that in most cases, the dose to the empty bladder is lower than when the bladder is full. Simultaneously, the doses to the bowels increase proportionally in the empty state of the bladder comparing to the full organ. Protection of the bowels, which are more radiosensitive, suggests treating the patients in the full state of the bladder. Early and late bowel toxicity should be investigated to establish clear standards of treatment.

  10. SU-E-T-232: Custom High-Dose-Rate Brachytherapy Surface Mold Applicators: The Importance Source to Skin Distance

    Energy Technology Data Exchange (ETDEWEB)

    Park, S; Demanes, J; Kamrava, M [UCLA School of Medicine, Los Angeles, CA (United States)

    2015-06-15

    Purpose: Surface mold applicators can be customized to fit irregular skin surfaces that are difficult to treat with other radiation therapy techniques. Optimal design of customized HDR skin brachytherapy is not well-established. We evaluated the impact of applicator thickness (source to skin distance) on target dosimetry. Methods: 27 patients had 34 treated sites: scalp 4, face 13, extremity 13, and torso 4. Custom applicators were constructed from 5–15 mm thick thermoplastic bolus molded over the skin lesion. A planar array of plastic brachytherapy catheters spaced 5–10 mm apart was affixed to the bolus. CT simulation was used to contour the target volume and to determine the prescription depth. Inverse planning simulated annealing followed by graphical optimization was used to plan and deliver 40–56 Gy in 8–16 fractions. Target coverage parameters (D90, Dmean, and V100) and dose uniformity (V110–200, D0.1cc, D1cc, and D2cc) were studied according to target depth (<5mm vs. ≥5mm) and applicator thickness (5–10mm vs. ≥10mm). Results: The average prescription depth was 4.2±1.5mm. The average bolus thickness was 9.2±2.4mm. The median CTV volume was 10.0 cc (0.2–212.4 cc). Similar target coverage was achieved with prescription depths of <5mm and ≥5mm (Dmean = 113.8% vs. 112.4% and D90 = 100.2% vs. 98.3%). The <5mm prescription depth plans were more uniform (D0.1cc = 131.8% vs. 151.8%). Bolus thickness <10mm vs. ≥10mm plans also had similar target coverage (Dmean = 118.2% vs. 110.7% and D90 = 100.1% vs. 99.0%). Applicators ≥10mm thick, however, provide more uniform target dosimetry (D0.1cc = 146.9% vs. 139.5%). Conclusion: Prescription depth is based upon the thickness of the lesion and upon the clinical needs of the patient. Applicators ≥10mm thick provide more dose uniformity than 5–10mm thick applicators. Applicator thickness is an important variable that should be considered during treatment planning to achieve optimal dose uniformity.

  11. SU-E-T-55: A Novel Applicator for High Dose Rate Brachytherapy Treatments of Ocular Conjunctiva

    Energy Technology Data Exchange (ETDEWEB)

    Koren, S; Bragilovski, D [Rabin Medical Center, Petah Tikva (Israel); Tafo, A Guemnie [Institut Gustave Roussy, Paris (France); Cohen, G [Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2015-06-15

    Purpose: To evaluate the clinical feasibility of IntraBeam intra operative kV irradiation beam device for ocular conjunctiva treatments. The Intra-Beam system offers a 4.4 mm diameter needle applicator, that is not suitable for treatment of a large surface with limits access. We propose an adaptor that will answer to this clinical need and provide initial dosimetry. Methods: The dose distribution of the needle applicator is non uniform and hence not suitable for treatment of relatively large surfaces. We designed an adapter to the needle applicator that will filter the X-rays and produce a conformal dose distribution over the treatment area while shielding surfaces to be spared. Dose distributions were simulated using FLUKA is a fully integrated particle physics Monte Carlo simulation package. Results: We designed a wedge applicator made of Polythermide window and stainless steel for collimating. We compare the dose distribution to that of the known needle and surface applicators. Conclusion: Initial dosimetry shows feasibility of this approach. While further refinements to the design may be warranted, the results support construction of a prototype and confirmation of the Monte Carlo dosimetry with measured data.

  12. Workflow efficiency for the treatment planning process in CT-guided high-dose-rate brachytherapy for cervical cancer.

    Science.gov (United States)

    Michaud, Anthony L; Benedict, Stanley; Montemayor, Eliseo; Hunt, Jon Paul; Wright, Cari; Mathai, Mathew; Mayadev, Jyoti S

    2016-01-01

    To investigate process efficiency, we present a prospective investigation of the treatment planning phase of image-guided brachytherapy (BT) for cervical cancer using a specific checklist. From October 2012 to January 2014, 76 BT procedures were consecutively performed. Prospective data on the CT-based treatment planning process was collected using a specific checklist which details the following steps: (1) dosimetry planning, (2) physician review start, (3) physician review time, (4) dosimetry processing, (5) physics review start, (6) physics review, and (7) procedural pause. Variables examined included the use of a pre-BT MRI, clinic duty conflicts, resident teaching, and the use of specific BT planners. Analysis was performed using descriptive statistics, t-test, and analysis of variance. Seventy-five prospectively gathered check