WorldWideScience

Sample records for high-dose regimen comprising

  1. Relative safety profiles of high dose statin regimens

    Directory of Open Access Journals (Sweden)

    Carlos Escobar

    2008-06-01

    Full Text Available Carlos Escobar, Rocio Echarri, Vivencio BarriosDepartment of Cardiology, Hospital Ramón y Cajal, Madrid, SpainAbstract: Recent clinical trials recommend achieving a low-density lipoprotein cholesterol level of <100 mg/dl in high-risk and <70 mg/dl in very high risk patients. To attain these goals, however, many patients will need statins at high doses. The most frequent side effects related to the use of statins, myopathy, rhabdomyolysis, and increased levels of transaminases, are unusual. Although low and moderate doses show a favourable profile, there is concern about the tolerability of higher doses. During recent years, numerous trials to analyze the efficacy and tolerability of high doses of statins have been published. This paper updates the published data on the safety of statins at high doses.Keywords: statins, high doses, tolerability, liver, muscle

  2. Extended high dose letrozole regimen versus short low dose letrozole regimen as an adjuvant to gonadotropin releasing hormone antagonist protocol in poor responders undergoing IVF-ET.

    Science.gov (United States)

    Fouda, Usama M; Sayed, Ahmed M

    2011-12-01

    To compare the efficacy and cost-effectiveness of extended high dose letrozole regimen/HPuFSH-gonadotropin releasing hormone antagonist (GnRHant) protocol with short low dose letrozole regimen/HPuFSH-GnRHant protocol in poor responders undergoing IVF-ET. In this randomized controlled trial, 136 women who responded poorly to GnRH agonist long protocol in their first IVF cycle were randomized into two equal groups using computer generated list and were treated in the second IVF cycle by either extended letrozole regimen (5 mg/day during the first 5 days of cycle and 2.5 mg/day during the subsequent 3 days) combined with HPuFSH-GnRHant protocol or short letrozole regimen (2.5 mg/day from cycle day 3-7) combined with HPuFSH-GnRHant protocol. There were no significant differences between both groups with regard to number of oocytes retrieved and clinical pregnancy rate (5.39 ± 2.08 vs. 5.20 ± 1.88 and 22.06% vs. 16.18%, respectively).The total gonadotropins dose and medications cost per cycle were significantly lower in extended letrozole group (44.87 ± 9.16 vs. 59.97 ± 14.91 ampoules and 616.52 ± 94.97 vs. 746.84 ± 149.21 US Dollars ($), respectively).The cost-effectiveness ratio was 2794 $ in extended letrozole group and 4616 $ in short letrozole group. Extended letrozole regimen/HPuFSH-GnRHant protocol was more cost-effective than short letrozole regimen/HPuFSH-GnRHant protocol in poor responders undergoing IVF-ET.

  3. Results of a Prospective Study of High-Dose or Conventional Anthracycline-Cyclophosphamide Regimen Plus Radiotherapy for Localized Adult Non-Hodgkin’s Primary Bone Lymphoma

    Directory of Open Access Journals (Sweden)

    A. Schmidt-Tanguy

    2014-01-01

    Full Text Available Background. Primary bone lymphoma (PBL is a rare entity that has only been reviewed in one prospective and small retrospective studies, from which it is difficult to establish treatment guidelines. We prospectively evaluated high-dose or conventional anthracycline-cyclophosphamide dose and radiotherapy for PBL. Patients and Methods. The GOELAMS prospective multicenter study (1986–1998 enrolled adults with localized high-grade PBL according to age and performance status (PS. Patients <60 years received a high-dose CHOP regimen (VCAP and those ≥60 years a conventional anthracycline-cyclophosphamide regimen (VCEP-bleomycin; all received intrathecal chemotherapy and local radiotherapy. Results. Among the 26 patients included (VCAP: 19; VCEP-bleomycin: 7, 39% had poor PS ≥2. With a median follow-up of 8 years, overall survival, event-free survival, and relapse-free survival were 64%, 62%, and 65%, respectively, with no significant difference between treatment groups. Poor PS was significantly associated with shorter OS and EFS. Conclusions. Our results confirm the efficacy of our age-based therapeutic strategy. High-doses anthracycline-cyclophosphamide did not improve the outcome. VCEP-bleomycin is effective and well tolerated for old patients. The intensification must be considered for patients with PS ≥2, a poor prognostic factor.

  4. Results of Hematopoietic Stem Cell Transplantation After Treatment With Different High-Dose Total-Body Irradiation Regimens in Five Dutch Centers

    International Nuclear Information System (INIS)

    Loes van Kempen-Harteveld, M.; Brand, Ronald; Kal, Henk B.; Verdonck, Leo F.; Hofman, Pieter; Schattenberg, Anton V.; Maazen, Richard W. van der; Cornelissen, Jan J.; Eijkenboom, Wil M.H.; Lelie, Johannes P. van der; Oldenburger, Foppe; Barge, Renee M.; Biezen, Anja van; Vossen, Jaak M.J.J.; Noordijk, Evert M.; Struikmans, Henk

    2008-01-01

    Purpose: To evaluate results of high-dose total-body irradiation (TBI) regimens for hematopoietic stem cell transplantation. Methods and Materials: A total of 1,032 patients underwent TBI in one or two fractions before autologous or allogeneic hematologic stem cell transplantation for acute leukemia and non-Hodgkin's lymphoma. The TBI regimens were normalized by using the biological effective dose (BED) concept. The BED values were divided into three dose groups. Study end points were relapse incidence (RI), non-relapse mortality (NRM), relapse-free survival (RFS), and overall survival (OS). Multivariate analysis was performed, stratified by disease. Results: In the highest TBI dose group, RI was significantly lower and NRM was higher vs. the lower dose groups. However, a significant influence on RFS and OS was not found. Relapses in the eye region were found only after shielding to very low doses. Age was of significant influence on OS, RFS, and NRM in favor of younger patients. The NRM of patients older than 40 years significantly increased, and OS decreased. There was no influence of age on RI. Men had better OS and RFS and lower NRM. Type of transplantation significantly influenced RI and NRM for patients with acute leukemia and non-Hodgkin's lymphoma. There was no influence on RFS and OS. Conclusions: Both RI and NRM were significantly influenced by the size of the BED of single-dose or two-fraction TBI regimens; OS and RFS were not. Age was of highly significant influence on NRM, but there was no influence of age on RI. Hyperfractionated TBI with a high BED might be useful, assuming NRM can be reduced

  5. Evaluation of the Efficacy and Safety of High Dose Short Duration Enrofloxacin Treatment Regimen for Uncomplicated Urinary Tract Infections in Dogs

    Science.gov (United States)

    Westropp, JL; Sykes, JE; Irom, S; Daniels, JB; Smith, A; Keil, D; Settje, T; Wang, Y; Chew, DJ

    2012-01-01

    Background Uncomplicated urinary tract infections (UTI) in dogs usually are treated with antimicrobial drugs for 10–14 days. Shorter duration antimicrobial regimens have been evaluated in human patients. Hypothesis A high dose short duration (HDSD) enrofloxacin protocol administered to dogs with uncomplicated UTI will not be inferior to a 14-day treatment regimen with amoxicillin-clavulanic acid. Animals Client-owned adult, otherwise healthy dogs with aerobic bacterial urine culture yielding ≥103 CFU/mL of bacteria after cystocentesis. Methods Prospective, multicenter, controlled, randomized blinded clinical trial. Enrolled dogs were randomized to group 1 (enrofloxacin 18–20 mg/kg PO q24h for 3 days) or group 2 (amoxicillin-clavulanic acid 13.75–25 mg/kg PO q12h for 14 days). Urine cultures were obtained at days 0, 10, and 21. Microbiologic and clinical cure rates were evaluated 7 days after antimicrobial treatment was discontinued. Lower urinary tract signs and adverse events also were recorded. Results There were 35 dogs in group 1 and 33 in group 2. The microbiologic cure rate was 77.1 and 81.2% for groups 1 and 2, respectively. The clinical cure rate was 88.6 and 87.9% for groups 1 and 2, respectively. Cure rates between groups did not differ according to the selected margin of noninferiority. Conclusions and Clinical Importance HDSD enrofloxacin treatment was not inferior to a conventional amoxicillin-clavulanic acid protocol for the treatment of uncomplicated bacterial UTI in dogs. Further research is warranted to determine if this protocol will positively impact owner compliance and decrease the emergence of antimicrobial resistance. PMID:22486931

  6. Efficacy and Safety of a Colistin Loading Dose, High-Dose Maintenance Regimen in Critically Ill Patients With Multidrug-Resistant Gram-Negative Pneumonia.

    Science.gov (United States)

    Elefritz, Jessica L; Bauer, Karri A; Jones, Christian; Mangino, Julie E; Porter, Kyle; Murphy, Claire V

    2017-09-01

    Emergence of multidrug-resistant (MDR) gram-negative (GN) pathogens and lack of novel antibiotics have increased the use of colistin, despite unknown optimal dosing. This study aimed to evaluate the safety and efficacy of a colistin loading dose, high-dose (LDHD) maintenance regimen in patients with MDR-GN pneumonia. A retrospective cohort analysis was performed comparing critically ill patients with MDR-GN pneumonia pre- and postimplementation of a colistin LDHD guideline with a primary outcome of clinical cure. Safety was assessed using incidence of acute kidney injury (AKI) based on RIFLE (risk, injury, failure, loss, end-stage renal disease) criteria. Seventy-two patients met the inclusion criteria (42 preimplementation and 30 postimplementation). Clinical cure was achieved in 23 (55%) patients in the preimplementation group and 20 (67%) patients in the postimplementation group ( P = .31). AKI occurred in 50% of the patients during the preimplementation period and 58% during the postimplementation period ( P = .59) with no difference in initiation rates of renal replacement therapy. The increased clinical cure rate after implementation of the colistin LDHD guideline did not reach statistical significance. The LDHD guideline, however, was not associated with an increased incidence of AKI, despite higher intravenous colistin doses. Opportunity exists to optimize colistin dosage while balancing toxicity, but larger studies are warranted.

  7. Bimonthly 24 h infusion of high-dose 5-fluorouracil vs EAP regimen in patients with advanced gastric cancer. A randomized phase II study.

    Science.gov (United States)

    Popov, I P; Jelić, S B; Krivokapić, Z V; Jezdić, S D; Pesko, P M; Micev, M T; Babić, D R

    2008-01-01

    To investigate the activity and toxicity of high dose (HD) infusional 5-FU in comparison to EAP regimen as first-line chemotherapy in patients with advanced gastric cancer. Histologically confirmed measurable advanced gastric cancer, age EAP arm: doxorubicin (40 mg/m(2)), etoposide (360 mg/m(2)), and cisplatin (80 mg/m(2)) every 28 d; HD 5-FU arm: 5-FU 2.6 g/m(2) 24 h infusion, biweekly. Sixty patients were randomized. Patient characteristics (arms EAP/HD 5-FU): Median age 57/55 yr, median PS 1/1, LAD (patients) 3/8, M1 (patients) 27/22. Median number of cycles (range): EAP arm 4 (2-8), HD 5-FU arm 2 (1-8). Worst toxicity per cycle (grade 3 and 4 in%): Neutropenia 20/3, thrombocytopenia 9/0, anemia 9/13, diarrhea 3/10, nausea 17/7, vomiting 10/0 for EAP and HD 5-FU arms, respectively. All patients were eligible for response in both arms. Confirmed response rate (95%CI): EAP arm 34% [16-50%]/HD 5-FU arm 10% (0-21%), no change: 46/40%, progression of disease: 20/50, respectively. Overall survival (range): EAP arm A 7 mo [3-27], HD 5-FU arm 6 mo (4-25). Infusional HD 5-FU showed a low incidence of severe toxicity. But given the low efficacy of 5-FU in the dosage we applied in the study, it cannot be recommended as a single treatment for further studies. Assessment of higher dose intensity and/or dose density of 5-FU, with introduction of other active drugs in combination, could be an option for further studies.

  8. The use of a sequential high dose recombinant interleukin 2 regimen after autologous bone marrow transplantation does not improve the disease free survival of patients with acute leukemia transplanted in first complete remission.

    Science.gov (United States)

    Blaise, D; Attal, M; Pico, J L; Reiffers, J; Stoppa, A M; Bellanger, C; Molina, L; Nedellec, G; Vernant, J P; Legros, M; Gabus, R; Huguet, F; Brandely, M; Hercend, T; Olive, D; Maraninchi, D

    1997-05-01

    We report the outcome of 50 consecutive patients with CR1 acute leukemia (AML = 22; ALL = 28) treated with autologous BMT, after cyclophosphamide and TBI, followed with a sequential high dose rIL2 regimen. rIL-2 (RU 49637 from Roussel-Uclaf, Romainville, France) was started after hematological reconstitution an average of 72 +/- 22 days post transplant. The schedule consisted of a continuous infusion over 5 cycles (Cycle 1: 5 days starting on day 1; cycle 2-5: 2 days starting on day 15, 29, 43 and 57). Patients were treated at 4 different dosages (12 (N = 40), 16 (N = 3), 20 (N = 2), 24 (N = 5) x 10(6) IU/m2/day). Toxicities were mainly related to capillary leak syndrome and thrombocytopenia. Patients received an average of 122 +/- 49 10(6) IU/m2. Two patients with AML died from toxicity. rIL-2 infusion was associated with very a high level of immune stimu-lation of both T-cells (P < 0.05) and natural killer (NK) cells (P < 0.05) and associated cytolytic functions (P < 0.05). With a minimal and median follow-up of 21 and 46 months, 3 year leukemia free survival is 41 +/- 6% overall, 39 +/- 10% and 43 +/- 8% for AML and ALL respectively. Relapse probabilities at 3 years are 59 +/- 11% for AML and 57 +/- 8% for ALL. We conclude that this short infusion of rIL-2 over 2 months, resulting in an increased immune stimulation, is not associated with a better leukemic control for patients with acute leukemia transplanted early after reaching first complete remission.

  9. Pharmacogenetics and Pharmacokinetics in high-dose alkylating chemotherapy

    NARCIS (Netherlands)

    Ekhart, G.C. (Corine)

    2008-01-01

    High-dose chemotherapy in combination with peripheral blood progenitor cell transplantation has been developed as a possible curative treatment modality in several solid tumours. A frequently used high-dose regimen in the Netherlands is the CTC regimen, which is a 4-day course of cyclophosphamide,

  10. The clinical pharmacology of alkylating agents in high-dose chemotherapy

    NARCIS (Netherlands)

    Huitema, A. D.; Smits, K. D.; Mathôt, R. A.; Schellens, J. H.; Rodenhuis, S.; Beijnen, J. H.

    2000-01-01

    Alkylating agents are widely used in high-dose chemotherapy regimens in combination with hematological support. Knowledge about the pharmacokinetics and pharmacodynamics of these agents administered in high doses is critical for the safe and efficient use of these regimens. The aim of this review is

  11. Selections of appropriate regimen of high-dose chemotherapy combined with adoptive cellular therapy with dendritic and cytokine-induced killer cells improved progression-free and overall survival in patients with metastatic breast cancer: reargument of such contentious therapeutic preferences.

    Science.gov (United States)

    Ren, Jun; Di, Lijun; Song, Guohong; Yu, Jing; Jia, Jun; Zhu, Yuling; Yan, Ying; Jiang, Hanfang; Liang, Xu; Che, Li; Zhang, Jie; Wan, Fengling; Wang, Xiaoli; Zhou, Xinna; Lyerly, Herbert Kim

    2013-10-01

    We hypothesized that combination of dendritic cell (DC) with autologous cytokine-induced killer (CIK) immunotherapy in setting of high-dose chemotherapy (HDC) would be effective for selected metastatic breast cancer (MBC) patients. Our previous work showed thiotepa could eradicate breast cancer stem cells. From 2004 to 2009, 79 patients received standard dose chemotherapy (SDC) of 75 mg/m(2) docetaxel and 75 mg/m(2) thiotepa versus 87 patients of HDC + DC/CIK: 120 mg/m(2) docetaxel to mobilize peripheral CD34(+) progenitor cells, a sequence of HDC (120 mg/m(2) docetaxel, plus 175 mg/m(2) thiotepa) + DC/CIK, with or without 400 mg/m(2) carboplatin depending upon bone marrow function. The endpoints were response rates (RR), progression-free survival (PFS), and overall survival (OS). Compared with SDC, PFS and OS were improved in HDC + DC/CIK (median PFS 10.2 vs. 3.7 months, P < 0.001; median OS 33.1 vs. 15.2 months, P < 0.001). Patients of pre-menopausal, HDC as first-line treatment after metastasis, or with visceral metastasis showed prolonged PFS and OS. SDC group also achieved the similar response as previous reports. Our study demonstrated the novel combination of HDC with DC/CIK to be an effective choice for the selected MBC population, in which choosing appropriate chemo regimens played important roles, and also specific HDC regimen plus DC/CIK immunotherapy showed the clinical benefits compared with chemotherapy alone.

  12. Gamma dosimetry of high doses

    International Nuclear Information System (INIS)

    Martinez C, T.; Galvan G, A.; Canizal, G.

    1991-01-01

    The gamma dosimetry of high doses is problematic in almost all the classic dosemeters either based on the thermoluminescence, electric, chemical properties, etc., because they are saturated to very high dose and they are no longer useful. This work carries out an investigation in the interval of high doses. The solid system of heptahydrate ferrous sulfate, can be used as solid dosemeter of routine for high doses of radiation. The proposed method is simple, cheap and it doesn't require sophisticated spectrophotometers or spectrometers but expensive and not common in some laboratories

  13. Immune reactivity after high-dose irradiation

    International Nuclear Information System (INIS)

    Gassmann, W.; Wottge, H.U.; von Kolzynski, M.; Mueller-Ruchholtz, W.

    1986-01-01

    Immune reactivity after total-body irradiation was investigated in rats using skin graft rejection as the indicator system. After sublethal irradiation with 10.5 Gy (approximately 50% lethality/6 weeks) the rejection of major histocompatibility complex allogeneic skin grafts was delayed significantly compared with nonirradiated control animals (28 versus 6.5 days). In contrast, skin grafts were rejected after 7.5 days in sublethally irradiated animals and 7 days in lethally irradiated animals if additional skin donor type alloantigens--namely, irradiated bone marrow cells--were given i.v. either simultaneously or with a delay of not more than 24 hr after the above conditioning regimen. These reactions were alloantigen-specific. They were observed in six different strain combinations with varying donors and recipients. Starting on day 2 after irradiation, i.v. injection of bone marrow gradually lost its effectivity and skin grafts were no longer rejected with uniform rapidity; skin donor marrow given on days 4 or 8 did not accelerate skin graft rejection at all. These data show that for approximately 1-2 days after high-dose total-body irradiation rats are still capable of starting a vigorous immune reaction against i.v.-injected alloantigens. The phenomenon of impaired rejection of skin grafted immediately after high-dose irradiation appears to result from the poor accessibility of skin graft alloantigens during the early postirradiation phase when vascularization of the grafted skin is insufficient

  14. High-dose vitamin C and cancer

    Directory of Open Access Journals (Sweden)

    Ahmet Unlu, M.D.

    2016-01-01

    Full Text Available Vitamin C (ascorbic acid, ascorbate is a basic compound that is of great importance with its role in various enzymatic reactions including the synthesis of collagen, as well as with its redox functions. Vitamin C has become the center of interest in cancer studies, in consequence of the facts that connective tissue changes and vitamin C deficiency were first alleged to be associated with cancer in the 1950s; and that high doses of vitamin C was asserted to be cytotoxic for cancer cells, later on. The results of the first study carried out in the 1970s were promising; but afterwards, the studies were ascertained to be faulty. Despite the positive results achieved from some laboratory and animal experiments, randomized clinical trials did not verify those findings, and no clear benefit of vitamin C for cancer treatment could be demonstrated. As for studies, where its use in combination with other cancer treatment regimens was assessed, conflicting results were obtained. Although intake of high doses of vitamin C is alleged to be harmless, based on that it is in the group of water soluble vitamins and is not stored in the body, there are many side effects and drug interactions reported in the literature. For now, it is better to abstain from this treatment, until the benefit of the treatment (if any is clearly demonstrated, considering the potential side effects and interactions.

  15. Methamphetamine treatment during development attenuates the dopaminergic deficits caused by subsequent high-dose methamphetamine administration

    OpenAIRE

    McFadden, Lisa M; Hoonakker, Amanda J; Vieira-Brock, Paula L; Stout, Kristen A; Sawada, Nicole M; Ellis, Jonathan D; Allen, Scott C; Walters, Elliot T; Nielsen, Shannon M; Gibb, James W; Alburges, Mario E; Wilkins, Diana G; Hanson, Glen R; Fleckenstein, Annette E

    2011-01-01

    Administration of high doses of methamphetamine (METH) causes persistent dopaminergic deficits in both nonhuman preclinical models and METH-dependent persons. Noteworthy, adolescent (i.e., postnatal day (PND) 40) rats are less susceptible to this damage than young adult (PND90) rats. In addition, biweekly treatment with METH, beginning at PND40 and continuing throughout development, prevents the persistent dopaminergic deficits caused by a “challenge” high-dose METH regimen when administered ...

  16. High-dose buprenorphine: perioperative precautions and management strategies.

    Science.gov (United States)

    Roberts, D M; Meyer-Witting, M

    2005-02-01

    Buprenorphine has been in clinical use in anaesthesia for several decades. Recently, the high-dose sublingual formulation (Subutex, Reckitt Benckiser, Slough, U.K.) has been increasingly used as maintenance therapy in opioid dependence, as an alternative to methadone and other pharmacological therapies. Buprenorphine has unique pharmacological properties making it well suited for use as a maintenance therapy in opioid dependence. However, these same properties may cause difficulty in the perioperative management of pain. Buprenorphine is a partial opioid agonist, attenuating the effects of supplemental illicit or therapeutic opioid agonists. As a result of its high receptor affinity, supplemental opioids do not readily displace buprenorphine from the opioid receptor in standard doses. High-dose buprenorphine has an extended duration of action that prolongs both of these effects. The perioperative management of patients stabilized on high-dose buprenorphine and undergoing surgery requires consideration of the likely analgesic requirements. Where possible the buprenorphine should be continued. Pain management should focus on maximizing non-opioid analgesia, local anaesthesia and non-pharmacological techniques. Where pain may not be adequately relieved by these methods, the addition of a full opioid agonist such as fentanyl or morphine at appropriate doses should be considered, accompanied by close monitoring in a high dependency unit. In situations where this regimen is unlikely to be effective, preoperative conversion to morphine or methadone may be an option. Where available, liaison with a hospital-based alcohol and drug service should always be considered.

  17. Concomitant chemoradiotherapy with high dose rate brachytherapy ...

    African Journals Online (AJOL)

    Concomitant chemoradiotherapy with high dose rate brachytherapy as a definitive treatment modality for locally advanced cervical cancer. T Refaat, A Elsaid, N Lotfy, K Kiel, W Small Jr, P Nickers, E Lartigau ...

  18. Fiber optics in high dose radiation fields

    International Nuclear Information System (INIS)

    Partin, J.K.

    1985-01-01

    A review of the behavior of state-of-the-art optical fiber waveguides in high dose (greater than or equal to 10 5 rad), steady state radiation fields is presented. The influence on radiation-induced transmission loss due to experimental parameters such as dose rate, total dose, irradiation history, temperature, wavelength, and light intensity, for future work in high dose environments are given

  19. Progress in high-dose radiation dosimetry

    International Nuclear Information System (INIS)

    Ettinger, K.V.; Nam, J.W.; McLaughlin, W.L.; Chadwick, K.H.

    1981-01-01

    The last decade has witnessed a deluge of new high-dose dosimetry techniques and expanded applications of methods developed earlier. Many of the principal systems are calibrated by means of calorimetry, although production of heat is not always the final radiation effect of interest. Reference systems also include a number of chemical dose meters: ferrous sulphate, ferrous-cupric sulphate, and ceric sulphate acidic aqueous solutions. Requirements for stable and reliable transfer dose meters have led to further developments of several important high-dose systems: amino acids and saccharides analysed by ESR or lyoluminescence, thermoluminescent materials, radiochromic dyes and plastics, ceric-cerous solutions analysed by potentiometry, and ethanol-chlorobenzene solutions analysed by high-frequency oscillometry. A number of other prospective dose meters are also treated in this review. In addition, an IAEA programme of high-dose standardization and intercomparison for industrial radiation processing is described. (author)

  20. Intracranial meningiomas after high-dose irradiation

    International Nuclear Information System (INIS)

    Soffer, D.; Gomori, J.M.; Siegal, T.; Shalit, M.N.

    1989-01-01

    Three patients who presented with intracranial meningiomas 12, 15, and 20 years, respectively, after therapeutic high-dose irradiation of a primary brain tumor are described. Analysis of these cases and similar documented cases suggests that meningiomas after high-dose irradiation constitute a recognizable entity. Patients with such tumors received radiation therapy at a young age (mean age, 9.4 years). After a latent period of 2 to 47 years (mean, 19.8 years) they developed meningiomas at the site of irradiation, at a much younger age than patients with ''spontaneous'' meningiomas. Similar to the situation with meningiomas after low-dose irradiation, a relatively high proportion of meningiomas induced by high-dose irradiation tend to be malignant and biologically aggressive. A very young age at the time of irradiation seems to predispose to the induction of malignant meningiomas, rather than benign tumors. These unusual features provide indirect evidence that high-dose radiation may play a role in the pathogenesis of meningiomas.41 references

  1. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  2. "Time sequential high dose of Cytarabine in acute myelocytic leukemia "

    Directory of Open Access Journals (Sweden)

    Ghavamzadeh A

    2003-05-01

    Full Text Available Given preliminary evidence of timed, sequential chemotherapy of high dose cytosine arabinoside the current study was initiated to assess the side effects and efficacy of this regimen in patients with newly acute myelocytic leukemia (AML. Nineteen adults who referred to Hematology-Oncology and Bone Marrow Transplantation (BMT research center of Tehran University of Medical Sciences were enrolled in a trial from Aug 1999 to Nov 2000. All patients had a Karnofski classification above 60%. At this time induction therapy consisted of daunorubicin or idarubicin given at a dose of 60 mg/m² and 12 mg/m² IV respectively on days 1-3, and cytarabine (Ara-C 100 mg/m² intravenously by continuous infusion on days 1-7, followed by Ara-C 1000 mg/m² given on day 8-10 every 12 hours by IV infusion. Consolidation therapy started after 35th day. Of 19 fully evaluable patients, 10 patients achieved a complete remission, whereas 36.6% patients succumbed to death due to regeneration failure. The clinical data show that the overall survival rate from diagnosis 55.5% (95% CI, 30.8-78.5 at 6 months for the entire cohort of the patients. Disease free survival is also 50% (95% CI, 26-74. Mean duration of death due to treatment was 20 days (range 17-29 after beginning the regimen. Presenting WBC counts, French-American-British (FAB classification, sex and age were not useful prognostic variables. Fever, diarrhea, nausea and vomiting and GI hemorrhage were seen in 19, 6, 4, 7 patients respectively. It seems the 3+7+3 regimen is a promising approach for the AML patients regarding to high complete remission rate, but more supportive care should be considered. Furthermore any, benefit in long-term outcome can’t be determined regardless to the choice of post remission therapy (e.g., GCSF, appropriate antibiotics and etc.

  3. High-dose irradiation of food

    International Nuclear Information System (INIS)

    Diehl, J.F.

    1999-01-01

    Studies performed on behalf of the International Project on Food Irradiation in the period from 1971 until 1980 resulted in the concluding statement that ''.the irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard; hence, toxicological testing of foods so treated is no longer required.'' Since then, licenses for food irradiation have been restricted to this maximum dose in any country applying this technology. Further testing programmes have been carried out investigating the wholesomeness or hazards of high-dose irradiation, but there has been little demand so far by the food industry for licensing of high-dose irradiation, as there is only a small range of products whose irradiation at higher doses offers advantages for given, intended use. These include eg. spices, dried herbs, meat products in flexible pouch packagings for astronauts, or patients with immune deficiencies. (orig./CB) [de

  4. High-dose erythropoietin for tissue protection

    DEFF Research Database (Denmark)

    Lund, Anton; Lundby, Carsten; Olsen, Niels Vidiendal

    2014-01-01

    BACKGROUND: The discovery of potential anti-apoptotic and cytoprotective effects of recombinant human erythropoietin (rHuEPO) has led to clinical trials investigating the use of high-dose, short-term rHuEPO therapy for tissue protection in conditions such as stroke and myocardial infarction....... Experimental studies have been favourable, but the clinical efficacy has yet to be validated. MATERIALS AND METHODS: We have reviewed clinical studies regarding the use of high-dose, short-term rHuEPO therapy for tissue protection in humans with the purpose to detail the safety and efficacy of r...... no effect of rHuEPO therapy on measures of tissue protection. Five trials including 1025 patients reported safety concerns in the form of increased mortality or adverse event rates. No studies reported reduced mortality. CONCLUSIONS: Evidence is sparse to support a tissue-protective benefit of r...

  5. A simple high-dose gentamicin regimen showed no side effects among neonates

    DEFF Research Database (Denmark)

    Blaabjerg, Anne Sofie; Kofoed, Poul-Erik; Dalegaard, Mette Correll

    2017-01-01

    INTRODUCTION: Treatment of infections in neonates with gentamicin is a balance between optimising bactericidal effect and minimising adverse effects. Previously, at the Neonatal Intensive Care Unit (NICU) at Kolding Hospital, Denmark, neonates suspected of having infections were treated daily...... and 2012 and treated with gentamicin were included retrospectively in the study. Neonates with trough serum (S)-gentamicin level ≥ 2.0 mg/l before the third dose were reviewed in detail. RESULTS: In total, S-gentamicin level was measured in 253 treated neonates of whom 7% displayed elevated trough values....... Neonates elevated S...

  6. High dose rate endobronchial brachytherapy - treatment technique

    International Nuclear Information System (INIS)

    Carvalho, Heloisa de Andrade; Aisen, Salim; Haddad, Cecilia Maria Kalil; Nadalin, Wladimir; Pedreira Junior, Wilson Leite; Chavantes, Maria Cristina

    1998-01-01

    High dose rate endobronchial brachytherapy is efficient in symptom relief due to obstructive endobronchial malignancies. However, it's role in survival improvement for patients with lung cancer is not yet established. The use of this treatment in increasing, specially in the developing countries. The purpose of this paper is to present the treatment technique used in the Radiotherapy Department of the Hospital da Clinicas, University of Sao Paulo, based on an experience of 60 cases treated with 180 procedures. Some practical suggestions and rules adopted in the Department are described. The severe complications rate is 6.7%, demonstrating an adequate patient selection associated with the technique utilized. (author)

  7. Neuroprotective potential of high-dose biotin.

    Science.gov (United States)

    McCarty, Mark F; DiNicolantonio, James J

    2017-11-01

    A recent controlled trial has established that high-dose biotin supplementation - 100 mg, three times daily - has a stabilizing effect on progression of multiple sclerosis (MS). Although this effect has been attributed to an optimization of biotin's essential cofactor role in the brain, a case can be made that direct stimulation of soluble guanylate cyclase (sGC) by pharmacological concentrations of biotin plays a key role in this regard. The utility of high-dose biotin in MS might reflect an anti-inflammatory effect of cGMP on the cerebral microvasculature, as well on oligodendrocyte differentiation and on Schwann cell production of neurotrophic factors thought to have potential for managing MS. But biotin's ability to boost cGMP synthesis in the brain may have broader neuroprotective potential. In many types of neurons and neural cells, cGMP exerts neurotrophic-mimetic effects - entailing activation of the PI3K-Akt and Ras-ERK pathways - that promote neuron survival and plasticity. Hippocampal long term potentiation requires nitric oxide synthesis, which in turn promotes an activating phosphorylation of CREB via a pathway involving cGMP and protein kinase G (PKG). In Alzheimer's disease (AD), amyloid beta suppresses this mechanism by inhibiting sGC activity; agents which exert a countervailing effect by boosting cGMP levels tend to restore effective long-term potentiation in rodent models of AD. Moreover, NO/cGMP suppresses amyloid beta production within the brain by inhibiting expression of amyloid precursor protein and BACE1. In conjunction with cGMP's ability to oppose neuron apoptosis, these effects suggest that high-dose biotin might have potential for the prevention and management of AD. cGMP also promotes neurogenesis, and may lessen stroke risk by impeding atherogenesis and hypertrophic remodeling in the cerebral vasculature. The neuroprotective potential of high-dose biotin likely could be boosted by concurrent administration of brain

  8. Treating tuberculosis with high doses of anti-TB drugs: mechanisms and outcomes.

    Science.gov (United States)

    Xu, Yuhui; Wu, Jianan; Liao, Sha; Sun, Zhaogang

    2017-10-03

    Tuberculosis (TB) is considered as one of the most serious threats to public health in many parts of the world. The threat is even more severe in the developing countries where there is a lack of advanced medical amenities and contemporary anti-TB drugs. In such situations, dosage optimization of existing medication regimens seems to be the only viable option. Therapeutic drug monitoring study results suggest that high-dose treatment regimens can compensate the low serum concentration of anti-TB drugs and shorten the therapy duration. The article presents a critical review on the possible changes that occur in the host and the pathogen upon the administration of standard and high-dose regimens. Some of the most common factors that are responsible for low anti-TB drug concentrations in the serum are differences in hosts' body weight, metabolic processing of the drug, malabsorption and/or drug-drug interaction. Furthermore, failure to reach the cavitary pulmonary and extrapulmonary tissues also contributes to the therapeutic inefficiency of the drugs. In such conditions, administration of higher doses can help in compensating the pathogenic outcomes of enhancement of the pathogen's physical barriers, efflux pumps and genetic mutations. The present article also presents a summary of the recorded treatment outcomes of clinical trials that were conducted to test the efficacy of administration of high dose of anti-tuberculosis drugs. This review will help physicians across the globe to understand the underlying pathophysiological changes (including side effects) that dictate the clinical outcomes in patients administered with standard and/or high dose anti-TB drugs.

  9. NIST high-dose calibration services

    International Nuclear Information System (INIS)

    Humphreys, J.C.

    1989-01-01

    There is a need for the standardization of high-dose measurements used in the radiation-processing industry in order to provide assured traceability to national standards. NIST provides dosimetry calibration services to this industry. One of these services involves administration of known absorbed doses of gamma rays to customer-supplied dosimeters. The dosimeters are packaged to provide electron equilibrium conditions and are irradiated in a standard 60 Co calibration facility; this provides a calibration of that batch of dosimeters. Another service consists of supplying to a customer calibrated transfer dosimeters for irradiation with the customer's radiation source. The irradiated transfer dosimeters are then returned to NIST for analysis; the results are reported to the customer, providing a calibration of the dose rate of the customer's source. (orig.)

  10. Onyx as radiation detector for high doses

    International Nuclear Information System (INIS)

    Teixeira, Maria Inês; Souza, Divanizia N.; Caldas, Linda V.E.

    2011-01-01

    A study of the thermoluminescent (TL) characteristics of white, black and stripped onyx samples is reported in this work. Onyx is a variety of chalcedony, a form of quartz. The onyx stone is considered nobler than marble. The irradiations were performed using a Gamma-Cell 220 system ( 60 Co). The TL emission curves presented two peaks around 150 °C and 210 °C for all samples. The dose–response curves showed a sublinear behavior between 0.5 Gy and 5 kGy, and the lower detection limit for the white onyx pellets was 1.5 mGy. The main dosimetric characteristics were studied, and the material showed good performance for high dose dosimetry.

  11. Nonlinear model of high-dose implantation

    International Nuclear Information System (INIS)

    Danilyuk, A.

    2001-01-01

    The models of high-dose implantation, using the distribution functions, are relatively simple. However, they must take into account the variation of the function of distribution of the implanted ions with increasing dose [1-4]. This variation takes place owing to the fact that the increase of the concentration of the implanted ions results in a change of the properties of the target. High-dose implantation is accompanied by sputtering, volume growth, diffusion, generation of defects, formation of new phases, etc. The variation of the distribution function is determined by many factors and is not known in advance. The variation within the framework of these models [1-4] is taken into account in advance by the introduction of intuitive assumptions on the basis of implicit considerations. Therefore, these attempts should be regarded as incorrect. The model prepared here makes it possible to take into account the sputtering of the target, volume growth and additional declaration on the implanted ions. Without any assumptions in relation to the variation of the distribution function with increasing dose. In our model it is assumed that the type of distribution function for small doses in a pure target substance is the same as in substances with implanted ions. A second assumption relates to the type of the distribution function valid for small doses in the given substances. These functions are determined as a result of a large number of theoretical and experimental investigations and are well-known at the present time. They include the symmetric and nonsymmetric Gauss distribution, the Pearson distribution, and others. We examine implantation with small doses of up to 10 14 - 10 15 cm -2 when the accurately known distribution is valid

  12. Ionization chamber for high dose measurements

    International Nuclear Information System (INIS)

    Rodrigues Junior, Ary de Araujo

    2005-01-01

    Industrial gamma irradiators facilities are designed for processing large amounts of products, which are exposed to large doses of gamma radiation. The irradiation, in industrial scale, is usually carried out in a dynamic form, where the products go through a 60 Co gamma source with activity of TBq to P Bq (k Ci to MCi). The dose is estimated as being directly proportional to the time that the products spend to go through the source. However, in some situations, mainly for research purposes or for validation of customer process following the ISO 11137 requirements, it is required to irradiate small samples in a static position with fractional deliver doses. The samples are put inside the irradiation room at a fixed distance from the source and the dose is usually determined using dosimeters. The dose is only known after the irradiation, by reading the dosimeter. Nevertheless, in the industrial irradiators, usually different kinds of products with different densities go through between the source and the static position samples. So, the dose rate varies in function of the product density. A suitable methodology would be to monitor the samples dose in real time, measuring the dose on line with a radiation detector, which would improve the dose accuracy and avoid the overdose. A cylindrical ionization chamber of 0.9 cm 3 has been developed for high-doses real-time monitoring, during the sample irradiation at a static position in a 60 Co gamma industrial plant. Nitrogen and argon gas at pressure of 10 exp 5 Pa (1 bar) was utilized to fill the ionization chamber, for which an appropriate configuration was determined to be used as a detector for high-dose measurements. To transmit the signal generated in the ionization chamber to the associated electronic and processing unit, a 20 m mineral insulated cable was welded to the ionization chamber. The signal to noise ratio produced by the detector was about 100. The dosimeter system was tested at a category I gamma

  13. Brachytherapy treatment with high dose rate

    International Nuclear Information System (INIS)

    Santana Rodriguez, Sergio Marcelino; Rodriguez Rodriguez, Lissi Lisbet; Ciscal Chiclana, Onelio Alberto

    2009-01-01

    Retrospectively analyze results and prognostic factors of cervical cancer patients treated with radio concomitant cisplatin-based chemotherapy, radiation therapy combined modality. Methods: From January 2003 to December 2007, 198 patients with invasive cervical cancer were treated at the Oncology Department of Hospital Robau Celestino Hernandez (brachytherapy performed at INOR). The most common age group was 31 to 40 years. The histology in squamous cell carcinoma accounted for 84.3% of cases. The treatment consisted of external pelvic irradiation and vaginal brachytherapy, high dose rate. Concomitant chemotherapy consisted of cisplatin 40 mg/m2 weekly with a maximum of 70 mg for 5 weeks. Results: 66.2% of patients completed 5 cycles of chemotherapy. The median overall survival was 39 months, overall survival, disease-free survival and survival free of locoregional recurrence at 5 years of 78%, 76% and 78.6% respectively .. We found that clinical stage, histological type (adenocarcinoma worst outcome) were statistically related to level of response. Conclusions: Treatment with external pelvic radiation, brachytherapy and concurrent weekly cisplatin in patients with stage IIIB cervical cancer is feasible in the Chilean public health system, well tolerated and results comparable to international literature. (Author)

  14. [High-dosed gestagen therapy of the metastatic mammary carcinoma (author's transl)].

    Science.gov (United States)

    Firusian, N; Becher, R

    1981-12-01

    Thirty patients with histologically proven metastatic mammary carcinoma were treated, after exhaustion of hormonal and cytostatic therapeutic means, with high-dosed medroxyprogesterone acetate (MPA) during a ten-day induction phase with 1000 mg MPAi.m. per day and then with 600 mg oral MPA per day. In eleven patients a complete or partial remission was achieved. The median period of remission comprised ten months. A positive relationship was found between the response to high-dosed MPA therapy and the length of free intervals. Side effects were tolerable.

  15. BALLISTIC RESISTANT ARTICLES COMPRISING TAPES

    NARCIS (Netherlands)

    VAN DER EEM, JORIS; HARINGS, JULES; JANSE, GERARDUS; TJADEN, HENDRIK

    2015-01-01

    The invention pertains to a ballistic-resistant moulded article comprising a compressed stack of sheets comprising reinforcing tapes having a tensile strength of at least 1.0 GPa, a tensile modulus of at least 40 GPa, and a tensile energy-to-break of at least 15 J/g, the direction of the tapes

  16. Classifying insulin regimens

    DEFF Research Database (Denmark)

    Neu, A; Lange, K; Barrett, T

    2015-01-01

    Modern insulin regimens for the treatment of type 1 diabetes are highly individualized. The concept of an individually tailored medicine accounts for a broad variety of different insulin regimens applied. Despite clear recommendations for insulin management in children and adolescents with type 1...

  17. High dose rate brachytherapy for oral cancer

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Koizumi, Masahiko; Ogawa, Kazuhiko; Furukawa, Souhei

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer. (author)

  18. High dose rate brachytherapy for oral cancer.

    Science.gov (United States)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Furukawa, Souhei; Koizumi, Masahiko; Ogawa, Kazuhiko

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer.

  19. High dose gamma-ray standard

    International Nuclear Information System (INIS)

    Macrin, R.; Moraru, R.

    1999-01-01

    The high gamma-ray doses produced in a gamma irradiator are used, mainly, for radiation processing, i.e. sterilization of medical products, processing of food, modifications of polymers, irradiation of electronic devices, a.s.o. The used absorbed doses depend on the application and cover the range 10 Gy to 100 MGy. The regulations in our country require that the response of the dosimetry systems, used for the irradiation of food and medical products, be calibrated and traceable to the national standards. In order to be sure that the products receive the desired absorbed dose, appropriate dosimetric measurements must be performed, including the calibration of the dosemeters and their traceability to the national standards. The high dose gamma-ray measurements are predominantly based on the use of reference radiochemical dosemeters. Among them the ferrous sulfate can be used as reference dosemeter for low doses (up to 400 Gy) but due to its characteristics it deserves to be considered a standard dosemeter and to be used for transferring the conventional absorbed dose to other chemical dosemeters used for absorbed doses up to 100 MGy. The study of the ferrous sulfate dosemeter consisted in preparing many batches of solution by different operators in quality assurance conditions and in determining for all batches the linearity, the relative intrinsic error, the repeatability and the reproducibility. The principal results are the following: the linear regression coefficient: 0.999, the relative intrinsic error: max.6 %, the repeatability (for P* = 95 %): max.3 %, the reproducibility (P* = 95%): max.5 %. (authors)

  20. Performance of thermoluminescent materials for high dose dosimetry

    International Nuclear Information System (INIS)

    Texeira, Maria I.; Cecatti, Sonia G.P.; Caldas, Linda V.E.

    2008-01-01

    Cases involving high-doses of ionizing radiation are becoming increasingly common.The objective of this work was to characterize thermoluminescent materials for the dosimetry of workers exposed to high doses. Samples of TLD-200, TLD-400 and TLD-800 pellets from Thermo Electron Corporation were studied in gamma high-doses. Dose-response curves were obtained for doses between 100 mGy and 100 Gy. The reproducibility, the lower detection limits and dose-response curves were obtained for all three materials. The different kinds of detectors show usefulness for dosimetry of workers exposed accidentally to high doses. (author)

  1. Ionic liquids comprising heteraromatic anions

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, William F.; Brennecke, Joan F.; Maginn, Edward J.; Mindrup, Elaine; Gurkan, Burcu; Price, Erica; Goodrich, Brett

    2018-04-24

    Some embodiments described herein relate to ionic liquids comprising an anion of a heteraromatic compound such as optionally substituted pyrrolide, optionally substituted pyrazolide, optionally substituted indolide, optionally substituted phospholide, or optionally substituted imidazolide. Methods and devices for gas separation or gas absorption related to these ionic liquids are also described herein.

  2. Acute renal failure in high dose carboplatin chemotherapy

    NARCIS (Netherlands)

    Frenkel, J.; Kool, G.; de Kraker, J.

    1995-01-01

    Carboplatin has been reported to cause acute renal failure when administered in high doses to adult patients. We report a 4 1/2-year-old girl who was treated with high-dose carboplatin for metastatic parameningeal embryonal rhabdomyosarcoma. Acute renal failure developed followed by a slow partial

  3. High-dose stabilized chlorite matrix WF10 prolongs cardiac xenograft survival in the hamster-to-rat model without inducing ultrastructural or biochemical signs of cardiotoxicity

    DEFF Research Database (Denmark)

    Hansen, A; Kemp, K; Kemp, E

    2001-01-01

    of high dose WF10 as a single drug regimen in the hamster-to-rat xenotransplantation model and searched for possible cardiotoxic side effects. WF10 prolonged cardiac xenograft survival, but did not induce tolerence or inhibit pathological signs of acute rejection. Hamsters from the donor population...

  4. Accelerated Irradiations for High Dose Microstructures in Fast Reactor Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Jiao, Zhijie [Univ. of Michigan, Ann Arbor, MI (United States)

    2017-03-31

    The objective of this project is to determine the extent to which high dose rate, self-ion irradiation can be used as an accelerated irradiation tool to understand microstructure evolution at high doses and temperatures relevant to advanced fast reactors. We will accomplish the goal by evaluating phase stability and swelling of F-M alloys relevant to SFR systems at very high dose by combining experiment and modeling in an effort to obtain a quantitative description of the processes at high and low damage rates.

  5. Treatment of the prostate cancer with high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Martinez, Alvaro; Torres Silva, Felipe

    2002-01-01

    The prostate cancer treatment in early stages is controversial. The high dose rate brachytherapy has been used like monotherapy or boost with external beam radiotherapy in advanced disease. This paper describes the technique and the advantages over other modalities

  6. High-dose dosimetry using natural silicate minerals

    International Nuclear Information System (INIS)

    Carmo, Lucas S. do; Mendes, Leticia; Watanabe, Shigueo; Rao, Gundu; Lucas, Natasha; Sato, Karina; Barbosa, Renata F.

    2015-01-01

    In the present study, certain natural silicate minerals such as aquamarine (AB), morganite (PB), goshenite (WB), white jadeite (JW), green jadeite (JG), pink tourmaline (PT) and two varieties of jadeite-like quartz, denoted here by JQ1 and JQ2, were investigated using the thermoluminescence technique to evaluate their potential for use as very-high- and high-dose dosimeters. These minerals respond to high doses of γ-rays of up to 1000 kGy and often to very high doses of up to 3000 kGy. The TL response of these minerals may be considered to be satisfactory for applications in high-dose dosimetry. Investigations of electron paramagnetic resonance and optically stimulated luminescence dosimetry are in progress. (author)

  7. High-dose dosimetry using natural silicate minerals

    Energy Technology Data Exchange (ETDEWEB)

    Carmo, Lucas S. do; Mendes, Leticia, E-mail: isatiro@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Watanabe, Shigueo; Rao, Gundu; Lucas, Natasha; Sato, Karina, E-mail: lacifid@if.usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Fisica. Departamento de Fisica Nuclear; Barbosa, Renata F., E-mail: profcelta@hotmail.com [Universidade Federal de Sao Paulo (UNIFESP), Santos, SP (Brazil). Departamento de Ciencias do Mar

    2015-07-01

    In the present study, certain natural silicate minerals such as aquamarine (AB), morganite (PB), goshenite (WB), white jadeite (JW), green jadeite (JG), pink tourmaline (PT) and two varieties of jadeite-like quartz, denoted here by JQ1 and JQ2, were investigated using the thermoluminescence technique to evaluate their potential for use as very-high- and high-dose dosimeters. These minerals respond to high doses of γ-rays of up to 1000 kGy and often to very high doses of up to 3000 kGy. The TL response of these minerals may be considered to be satisfactory for applications in high-dose dosimetry. Investigations of electron paramagnetic resonance and optically stimulated luminescence dosimetry are in progress. (author)

  8. Evaluation of Low- Versus High-dose Valganciclovir for Prevention of Cytomegalovirus Disease in High-risk Renal Transplant Recipients.

    Science.gov (United States)

    Gabardi, Steven; Asipenko, Natalya; Fleming, James; Lor, Kevin; McDevitt-Potter, Lisa; Mohammed, Anisa; Rogers, Christin; Tichy, Eric M; Weng, Renee; Lee, Ruth-Ann

    2015-07-01

    Despite proven efficacy of prolonged cytomegalovirus (CMV) prophylaxis using valganciclovir 900 mg/day, some centers use 450 mg/day due to reported success and cost savings. This multicenter, retrospective study compared the efficacy and safety of 6 months of low-dose versus high-dose valganciclovir prophylaxis in high-risk, donor-positive/recipient-negative, renal transplant recipients (RTR). Two hundred thirty-seven high-risk RTR (low-dose group = valganciclovir 450 mg/day [n = 130]; high-dose group = valganciclovir 900 mg/day [n = s7]) were evaluated for 1-year CMV disease prevalence. Breakthrough CMV, resistant CMV, biopsy-proven acute rejection (BPAR), graft loss, opportunistic infections (OI), new-onset diabetes after transplantation (NODAT), premature valganciclovir discontinuation, renal function and myelosuppression were also assessed. Patient demographics and transplant characteristics were comparable. Induction and maintenance immunosuppression were similar, except for more early steroid withdrawal in the high-dose group. Similar proportions of patients developed CMV disease (14.6% vs 24.3%; P = 0.068); however, controlling CMV risk factor differences through multivariate logistic regression revealed significantly lower CMV disease in the low-dose group (P = 0.02; odds ratio, 0.432, 95% confidence interval, 0.211-0.887). Breakthrough and resistant CMV occurred at similar frequencies. There was no difference in renal function or rates of biopsy-proven acute rejection, graft loss, opportunistic infections, or new-onset diabetes after transplantation. The high-dose group had significantly lower mean white blood cell counts at months 5 and 6; however, premature valganciclovir discontinuation rates were similar. Low-dose and high-dose valganciclovir regimens provide similar efficacy in preventing CMV disease in high-risk RTR, with a reduced incidence of leukopenia associated with the low-dose regimen and no difference in resistant CMV. Low-dose valganciclovir

  9. The effectiveness of low-dose and high-dose tranexamic acid in posterior lumbar interbody fusion: a double-blinded, placebo-controlled randomized study.

    Science.gov (United States)

    Kim, Ki-Tack; Kim, Cheung-Kue; Kim, Yong-Chan; Juh, Hyung-Suk; Kim, Hyo-Jong; Kim, Hyeon-Soo; Hong, Se Jung; Hey, Hwee Weng Dennis

    2017-11-01

    Tranexamic acid is a proven drug used for reduction of intraoperative blood loss in spinal surgery. However, optimal dosing considering risk/benefits is not well established owing to the heterogeneity in patient selection and surgical procedures of previous studies. This study aimed to evaluate the effectiveness and safety of various tranexamic acid regimens in reducing perioperative blood loss in single-level posterior lumbar interbody fusion (PLIF). Patients were randomly grouped into three different interventions: low-dose tranexamic acid (LD), high-dose tranexamic acid (HD), and placebo-controlled (PC) groups. The HD and LD groups received 10 and 5 mg/kg of bolus loading dose and 2 and 1 mg/kg of continuous infusion until 5 h after surgery, respectively. Data on patient demographics and preoperative and 24-h postoperative laboratory values were collected. Outcome parameters include intraoperative blood loss, 24-h postoperative blood loss, and blood loss during removal of the last drain. Seventy-two patients (mean age 63.3 ± 7.6 years) showed similar baseline characteristics. Intraoperatively, blood loss was reduced by the administration of tranexamic acid (P = 0.04), contributed predominantly by a difference between the LD and HD groups (123 mL; P tranexamic acid use were noted. Tranexamic acid administration for single-level PLIF was effective and safe in reducing perioperative blood loss in a dose-dependent manner. An HD regimen comprising 10 mg/kg of bolus loading dose and 2 mg/kg/h of continuous infusion is recommended. Level 1 study according to Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence.

  10. Delayed rhabdomyolysis with paclitaxel, ifosfamide, carboplatin, and etoposide regimen: a case report.

    Science.gov (United States)

    Sokolova, Alexandra; Chan, Onyee; Ullah, Waqas; Hamdani, Auon Abbas; Anwer, Faiz

    2017-04-11

    High-dose chemotherapy with autologous stem cell rescue is commonly used for the treatment of relapsed germ cell tumors. We report the first case of delayed rhabdomyolysis with paclitaxel, ifosfamide, carboplatin, and etoposide regimen. We report a case of a 21-year-old African-American man diagnosed with relapsed non-seminomatous germ cell tumor who received high-dose chemotherapy with carboplatin and etoposide following TIGER trial arm B off-protocol. His course was complicated by muscle pain and rhabdomyolysis after cycle 4 on day +12 after infusion of autologous stem cells. To the best of our knowledge, this complication has not been reported with this regimen. A differential diagnosis of sepsis and neutropenic fever along with side effects of high-dose chemotherapy were considered, but based on the timing of events, it was concluded that the etiology of rhabdomyolysis is high-dose chemotherapy. Rhabdomyolysis was successfully treated with hydration and did not recur during subsequent cycle 5. Delayed rhabdomyolysis after high-dose chemotherapy with paclitaxel, ifosfamide, carboplatin, and etoposide regimen has not been previously reported and needs to be considered for preventive strategy and prompt diagnosis and treatment to avoid renal complications. Physicians should have a low threshold to check creatine kinase enzymes in patients with unexplained muscle pain or renal insufficiency after high-dose chemotherapy.

  11. Hyperfractionated high-dose total body irradiation in bone marrow transplantation for Ph{sup 1}-positive acute lymphoblastic leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Akira; Ebihara, Yasuhiro; Mitsui, Tetsuo [Tokyo Univ. (Japan). Hospital of the Institute of Medical Science] [and others

    1998-12-01

    In two cases of Philadelphia-positive childhood acute lymphoblastic leukemia (Ph{sup 1} ALL), we performed allogeneic bone marrow transplantation (AlloBMT) with preconditioning regimen, including hyperfractionated high-dose total body irradiation (TBI) (13.5 Gy, in 9 fractions). Their disease statuses at BMT were hematological relapse in case 1 and molecular relapse in case 2. Bone marrow donors were unrelated in case 1, and HLA was a partially mismatched mother in case 2. Regimen-related toxicity was tolerable in both cases. Hematological recovery was rapid, and engraftment was obtained on day 14 in case 1 and on day 12 in case 2. BCR/ABL message in bone marrow disappeared on day 89 in case 1 and on day 19 in case 2 and throughout their subsequent clinical courses. Although short-term MTX and Cy-A continuous infusion were used for GVHD prophylaxis, grade IV GVHD was observed in case 1 and grade III in case 2. Both cases experienced hemorrhagic cystitis because of adenovirus type 11 infection. Although case 1 died of interstitial pneumonitis on day 442, case 2 has been free of disease through day 231. AlloBMT for Ph{sup 1} ALL with preconditioning regimen including hyperfractionated high-dose TBI is considered to be worth further investigation. (author)

  12. High Dose Cyclophosphamide without Stem Cell Rescue in 207 Patients with Aplastic anemia and other Autoimmune Diseases

    Science.gov (United States)

    DeZern, Amy E.; Petri, Michelle; Drachman, Daniel B.; Kerr, Doug; Hammond, Edward R.; Kowalski, Jeanne; Tsai, Hua-Ling; Loeb, David M.; Anhalt, Grant; Wigley, Fredrick; Jones, Richard J.; Brodsky, Robert A.

    2011-01-01

    High-dose cyclophosphamide has long been used an anticancer agent, a conditioning regimen for hematopoietic stem cell transplantation and as potent immunosuppressive agent in autoimmune diseases including aplastic anemia. High-dose cyclophosphamide is highly toxic to lymphocytes but spares hematopoietic stem cells because of their abundant levels of aldehyde dehydrogenase, the major mechanism of cyclophosphamide inactivation. High dose cyclophosphamide therapy induces durable remissions in most patients with acquired aplastic anemia. Moreover, high-dose cyclophosphamide without hematopoietic stem cell rescue has shown activity in a variety of other severe autoimmune diseases. Here we review the history of cyclophosphamide as is applies to aplastic anemia (AA) and other autoimmune diseases. Included here are the historical data from early patients treated for AA as well as an observational retrospective study in a single tertiary care hospital. This latter component was designed to assess the safety and efficacy of high-dose cyclophosphamide therapy without stem cell rescue in patients with refractory autoimmune diseases. We analyzed fully the 140 patients with severe, progressive autoimmune diseases treated. All patients discussed here received cyclophosphamide, 50 mg/kg per day for 4 consecutive days. Response, relapse and overall survival were measured. Response was defined as a decrease in disease activity in conjunction with a decrease or elimination of immune modulating drugs. Relapse was defined as worsening disease activity and/or a requirement of an increase in dose of, or administration of new, immunosuppressive medications. Hematologic recovery occurred in all patients. The overall response rate of the was 95%, and 44% of those patients remain progression-free with a median follow up time of 36 (range 1–120) months for the 140 patients analyzed together. The overall actuarial and event free survival across all diseases at 60 months is 90.7% and 20

  13. Methamphetamine treatment during development attenuates the dopaminergic deficits caused by subsequent high-dose methamphetamine administration.

    Science.gov (United States)

    McFadden, Lisa M; Hoonakker, Amanda J; Vieira-Brock, Paula L; Stout, Kristen A; Sawada, Nicole M; Ellis, Jonathan D; Allen, Scott C; Walters, Elliot T; Nielsen, Shannon M; Gibb, James W; Alburges, Mario E; Wilkins, Diana G; Hanson, Glen R; Fleckenstein, Annette E

    2011-08-01

    Administration of high doses of methamphetamine (METH) causes persistent dopaminergic deficits in both nonhuman preclinical models and METH-dependent persons. Noteworthy, adolescent [i.e., postnatal day (PND) 40] rats are less susceptible to this damage than young adult (PND90) rats. In addition, biweekly treatment with METH, beginning at PND40 and continuing throughout development, prevents the persistent dopaminergic deficits caused by a "challenge" high-dose METH regimen when administered at PND90. Mechanisms underlying this "resistance" were thus investigated. Results revealed that biweekly METH treatment throughout development attenuated both the acute and persistent deficits in VMAT2 function, as well as the acute hyperthermia, caused by a challenge METH treatment. Pharmacokinetic alterations did not appear to contribute to the protection afforded by the biweekly treatment. Maintenance of METH-induced hyperthermia abolished the protection against both the acute and persistent VMAT2-associated deficits suggesting that alterations in thermoregulation were caused by exposure of rats to METH during development. These findings suggest METH during development prevents METH-induced hyperthermia and the consequent METH-related neurotoxicity. Copyright © 2011 Wiley-Liss, Inc.

  14. Oral cryotherapy for the prevention of high-dose melphalan-induced stomatitis in allogeneic hematopoietic stem cell transplant recipients.

    Science.gov (United States)

    Aisa, Yoshinobu; Mori, Takehiko; Kudo, Masumi; Yashima, Tomoko; Kondo, Sakiko; Yokoyama, Akihiro; Ikeda, Yasuo; Okamoto, Shinichiro

    2005-04-01

    The purpose of this study was to evaluate the efficacy of oral cryotherapy to prevent high-dose melphalan-induced stomatitis. Eighteen consecutive recipients of allogeneic hematopoietic stem cell transplant conditioned with high-dose melphalan (140 mg/m2) in combination with fludarabine alone or with fludarabine and additional chemotherapy or radiation were enrolled. The severity of stomatitis was graded according to the National Cancer Institute Common Toxicity Criteria. Patients were kept on oral cryotherapy using ice chips and ice-cold water shortly before, during, and for additional 90 min after completion of melphalan administration. Only two of 18 patients (11.1%) developed grade 2 or 3 stomatitis while six of seven patients in the historical control developed it (85.7%; P=0.001). These results suggested that oral cryotherapy could effectively prevent stomatitis caused by high-dose melphalan, and we recommend that it should be incorporated into the conditioning regimen with high-dose melphalan.

  15. Implementation of high-dose chemical dosimetry for industrial facilities

    International Nuclear Information System (INIS)

    Conceicao, Cirilo Cezar Sant'Anna da

    2006-01-01

    The purpose of this work is the implementation of methodology for high dose measurements using chemical dosimeters in liquid phase, traceable to the international metrology system, and make available in the country, the standard of high-dose to industrial irradiation facilities and research irradiators, trough the quality program with comparative measurements and direct use of the standard dosimeters in routine. The use of these low cost dosimetry systems in industrial irradiation facilities, assists to the certification requirements and it can reduce the costs with dosimetry for approximately 20% of the total dosimetry costs, using these systems in routine measurements and validation process, largely substituting the imported PMMA dosimeters, among others. (author)

  16. Statistical behavior of high doses in medical radiodiagnosis

    International Nuclear Information System (INIS)

    Barboza, Adriana Elisa

    2014-01-01

    This work has as main purpose statistically estimating occupational exposure in medical diagnostic radiology in cases of high doses recorded in 2011 at national level. For statistical survey of this study, doses of 372 IOE's diagnostic radiology in different Brazilian states were evaluated. Data were extracted from the work of monograph (Research Methodology Of High Doses In Medical Radiodiagnostic) that contains the database's information Sector Management doses of IRD/CNEN-RJ, Brazil. The identification of these states allows the Sanitary Surveillance (VISA) responsible, becomes aware of events and work with programs to reduce these events. (author)

  17. Study of teflon pads as high doses dosemeters

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2013-01-01

    The aim of this work is to study the Teflon, which is used as a binder in the manufacture of dosimetric tablets, for the feasibility of this material as high dose dosemeter. In this paper we used the technique of thermally stimulated luminescence (OSL) to characterize the dosimetric properties of Teflon. Teflon samples were exposed to different doses of radiation, using a source of gamma radiation ( 60 Co). It was obtained dose-response curve between 100 Gy to 50 kGy and reproducibility of OSL response. The preliminary results show that Teflon is a useful material to high dose dosimetry

  18. Pentobarbital quantitation using EMIT serum barbiturate assay reagents: application to monitoring of high-dose pentobarbital therapy.

    Science.gov (United States)

    Pape, B E; Cary, P L; Clay, L C; Godolphin, W

    1983-01-01

    Pentobarbital serum concentrations associated with a high-dose therapeutic regimen were determined using EMIT immunoassay reagents. Replicate analyses of serum controls resulted in a within-assay coefficient of variation of 5.0% and a between-assay coefficient of variation of 10%. Regression analysis of 44 serum samples analyzed by this technique (y) and a reference procedure (x) were y = 0.98x + 3.6 (r = 0.98; x = ultraviolet spectroscopy) and y = 1.04x + 2.4 (r = 0.96; x = high-performance liquid chromatography). Clinical evaluation of the results indicates the immunoassay is sufficiently sensitive and selective for pentobarbital to allow accurate quantitation within the therapeutic range associated with high-dose therapy.

  19. Use of glasses as radiation detectors for high doses

    International Nuclear Information System (INIS)

    Caldas, L.

    1989-08-01

    Glass samples were tested in relation to the possibility of use in high dose dosimetry in medical and industrial areas. The main characteristics were determined: detection threshold, reproducibility, response to gamma radiation of 137 Cs and 6 Co and thermal decay at ambient temperature, with the use of optical absorption and thermoluminesce techniques. (author) [pt

  20. Oval pulsed high-dose dexamethasone for myositis

    NARCIS (Netherlands)

    Hoogendijk, JE; Wokke, JHJ; de Visser, M

    To study the short-term effect of oral pulsed high-dose dexamethasone for myositis we treated eight newly diagnosed patients with three 28-day cycles of oral dexamethasone. Primary outcome measures were muscle strength, pain, and serum creatine kinase activity. Sis patients responded. Side effects

  1. Oral pulsed high-dose dexamethasone for myositis

    NARCIS (Netherlands)

    van der Meulen, M. F.; Hoogendijk, J. E.; Wokke, J. H.; de Visser, M.

    2000-01-01

    To study the short-term effect of oral pulsed high-dose dexamethasone for myositis we treated eight newly diagnosed patients with three 28-day cycles of oral dexamethasone. Primary outcome measures were muscle strength, pain, and serum creatine kinase activity. Six patients responded. Side effects

  2. Safety and tolerability of high doses of glucocorticoides

    Directory of Open Access Journals (Sweden)

    Rakić Branislava D.

    2016-01-01

    Full Text Available Introduction: Treatment of acute lymphoblastic leukemia includes the use of high doses of glucocorticoides (prednisone and dexamethasone, which significantly increase the success of therapy due to lymphocytolitic effect. The aim: The aim of the study was to determine tolerability of high doses of prednisone and dexamethasone in children with acute lymphoblastic leukemia and the structure and the intensity of adverse effects, occurred after application of these medicines. Subjects and methods: In a prospective study, we analyzed adverse effects of high doses of glucocorticoides in children suffering acute lymphoblastic leukemia treated in the Institute for Child and Youth Health Care of Vojvodina, since December 2010. until October 2014, were analyzed. This study included 18 patients, aged from 2 to 15 years. Results: Hyperglycemia appeared in 89% of patients treated with prednisone and in 61% of patients treated with dexamethasone. In order to control the high blood glucose level (above 10 mmol /L, in 11% of patients insulin was used. Hypertension appeared in 28% patients treated with prednisone and dexamethasone. Antihypertensives were needed for regulation in 17% patients. Hypopotassemia and hypocalcaemia were significantly more expressed after the use of prednisone in comparison to dexamethasone. In 11% of patients, the treatment with dexamethasone caused depressive behavior, followed by agitation. Conclusion: Adverse effects of dexamethasone and prednisone, administered in high doses in children with ALL were known, expected and reversible. Adverse reactions usually disappeared spontaneously or after short-term symptomatic therapy.

  3. Relevance of high-dose chemotherapy in solid tumours

    NARCIS (Netherlands)

    Nieboer, P; de Vries, EGE; Mulder, NH; van der Graaf, WTA

    Drug resistance is a major problem in the treatment of solid tumours. Based on a steep dose-response relationship for especially alkylating agents on tumour cell survival, high-dose chemotherapy was considered of interest for the treatment of solid tumours. Results of phase 1 and 2 studies with

  4. Bortezomib or high-dose dexamethasone for relapsed multiple myeloma

    NARCIS (Netherlands)

    P.G. Richardson (Paul Gerard); P. Sonneveld (Pieter); M.W. Schuster (Michael); D. Irwin (David); E.A. Stadtmauer (Edward); T. Facon (Thierry); J-L. Harousseau (Jean-Luc); D. Ben-Yehuda (Dina); S. Lonial (Sagar); H. Goldschmidt (Hartmut); D. Reece (Donna); J.F. San Miguel (Jesús Fernando); J. Bladé (Joan); M. Boccadoro (Mario); J. Cavenagh (Jamie); W. Dalton (William); A.L. Boral (Anthony); D.-L. Esseltine (Dixie-Lee); J.B. Porter (Jane); D. Schenkein (David); K.C. Anderson (Kenneth)

    2005-01-01

    textabstractBACKGROUND: This study compared bortezomib with high-dose dexamethasone in patients with relapsed multiple myeloma who had received one to three previous therapies. METHODS: We randomly assigned 669 patients with relapsed myeloma to receive either an intravenous bolus of bortezomib (1.3

  5. Unusual complication and successful high-dose chemotherapy ...

    African Journals Online (AJOL)

    ... treated with high-dose chemotherapy in our institution, complicated by unusual bilateral renal vein tumour thrombi and tumour lysis syndrome. We believe this unique case highlights the need for early recognition of current and potential complications on staging computed tomography imaging, as well as successful use of ...

  6. High-dose secondary calibration laboratory accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Humphreys, J.C. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

    1993-12-31

    There is a need for high-dose secondary calibration laboratories to serve the multi-billion dollar radiation processing industry. This need is driven by the desires of industry for less costly calibrations and faster calibration-cycle response time. Services needed include calibration irradiations of routine processing dosimeters and the supply of reference standard transfer dosimeters for irradiation in the production processing facility. In order to provide measurement quality assurance and to demonstrate consistency with national standards, the high-dose secondary laboratories would be accredited by means of an expansion of an existing National Voluntary Laboratory Accreditation Program. A laboratory performance criteria document is under development to implement the new program.

  7. High-dose secondary calibration laboratory accreditation program

    International Nuclear Information System (INIS)

    Humphreys, J.C.

    1993-01-01

    There is a need for high-dose secondary calibration laboratories to serve the multi-billion dollar radiation processing industry. This need is driven by the desires of industry for less costly calibrations and faster calibration-cycle response time. Services needed include calibration irradiations of routine processing dosimeters and the supply of reference standard transfer dosimeters for irradiation in the production processing facility. In order to provide measurement quality assurance and to demonstrate consistency with national standards, the high-dose secondary laboratories would be accredited by means of an expansion of an existing National Voluntary Laboratory Accreditation Program. A laboratory performance criteria document is under development to implement the new program

  8. Anticoagulation and high dose liver radiation. A preliminary report

    International Nuclear Information System (INIS)

    Lightdale, C.J.; Wasser, J.; Coleman, M.; Brower, M.; Tefft, M.; Pasmantier, M.

    1979-01-01

    Two groups of patients were observed for evidence of acute radiation hepatitis during high dose radiation to the liver. The first group of 18 patients with metastatic liver disease received an average of 4,050 rad to the whole liver. Half received anticoagulation with warfarin. One patient on anticoagulation developed evidence of acute radiation hepatitis while 2 patients did so without anticoagulation. Eleven patients with Hodgkin's disease received 4,000 rad to the left lobe of the liver during extended field radiation. Four of these 11 patients were anticoagulated to therapeutic range. Only one of the fully anticoagulated patients showed changes on liver scan consistent with radiation hepatitis whereas three did so without anticoagulation. No serious sequelae from anticoagulation occurred in either group. These preliminary data suggest that anticoagulation may be safely administered with high dose hepatic radiation and that further trials with anticoagulation are warranted

  9. Radiotherapy and high-dose chemotherapy in advanced Ewing's tumors

    International Nuclear Information System (INIS)

    Pape, H.; Glag, M.; Gripp, S.; Wittkamp, M.; Schmitt, G.; Laws, H.J.; Kaik, B. van; Goebel, U.; Burdach, S.; Juergens, H.

    1999-01-01

    Background: Ewing's tumors are sensitive to radio- and chemotherapy. Patients with multifocal disease suffer a poor prognosis. Patients presenting primary bone marrow involvement or bone metastases at diagnosis herald a 3-year disease-free survival below 15%. The European Intergroup Cooperative Ewing's Sarcoma Study (EICESS) has established the following indications for high-dose therapy in advanced Ewing's tumors: Patients with primary multifocal bone disease, patients with early ( [de

  10. Effect of high-dose oral multivitamins and minerals in participants not treated with statins in the randomized Trial to Assess Chelation Therapy (TACT).

    Science.gov (United States)

    Issa, Omar M; Roberts, Rhonda; Mark, Daniel B; Boineau, Robin; Goertz, Christine; Rosenberg, Yves; Lewis, Eldrin F; Guarneri, Erminia; Drisko, Jeanne; Magaziner, Allan; Lee, Kerry L; Lamas, Gervasio A

    2018-01-01

    In a prespecified subgroup analysis of participants not on statin therapy at baseline in the TACT, a high-dose complex oral multivitamins and multimineral regimen was found to have a large unexpected benefit compared with placebo. The regimen tested was substantially different from any vitamin regimen tested in prior clinical trials. To explore these results, we performed detailed additional analyses of participants not on statins at enrollment in TACT. TACT was a factorial trial testing chelation treatments and a 28-component high-dose oral multivitamins and multiminerals regimen versus placebo in post-myocardial infarction (MI) patients 50 years or older. There were 460 (27%) of 1,708 TACT participants not taking statins at baseline, 224 (49%) were in the active vitamin group and 236 (51%) were in the placebo group. Patients were enrolled at 134 sites around the United States and Canada. Daily high-dose oral multivitamins and multiminerals (6 tablets, active or placebo). The primary end point of TACT was time to the first occurrence of any component of the composite end point: all-cause mortality, MI, stroke, coronary revascularization, or hospitalization for angina. The primary end point occurred in 137 nonstatin participants (30%), of which 51 (23%) of 224 were in the active group and 86 (36%) of 236 were taking placebo (hazard ratio, 0.62; 95% confidence interval, 0.44-0.87; P=.006). Results in the key TACT secondary end point, a combination of cardiovascular mortality, stroke, or recurrent MI, was consistent in favoring the active vitamin group (hazard ratio, 0.46; 95% confidence interval, 0.28-0.75; P=.002). Multiple end point analyses were consistent with these results. High-dose oral multivitamin and multimineral supplementation seem to decrease combined cardiac events in a stable, post-MI population not taking statin therapy at baseline. These unexpected findings are being retested in the ongoing TACT2. Copyright © 2017 The Authors. Published by Elsevier

  11. A novel theory of radiation damage at high doses

    International Nuclear Information System (INIS)

    Seeger, A.; Stuttgart Univ.

    1989-01-01

    Deviations of radiation damage (in the case of metals usually monitored by the residual electrical resistivity) from proportionality with the irradiation dose have so far been analysed almost exclusively in terms of extensions of models originally developed for small doses. The present theory considers the opposite limit i.e. the quasi-saturated state. It is argued that at high doses the Lueck-Sizmann effect may result in a self-organization of clusters of vacancies and self-interstitials, forming a heterogeneous froth. Possible structures of this froth and its effect on the electrical resistivity of metals are discussed. The model is shown to account for the dependence of the ''saturation resistivity'' on the nature of the irradiation as well as for several other hitherto poorly explained observations. Among them are the electrical-resistivity variation induced by high-dose irradiation with heavy ions, the amorphization of certain alloys by high-dose electron irradiation, and the occurrence of ordered arrays of stacking-fault tetrahedra after in-situ irradiations in high-voltage electron microscopes. (author)

  12. Radiophotoluminescence light scope for high-dose dosimetry

    International Nuclear Information System (INIS)

    Sato, Fuminobu; Zushi, Naoki; Sakiyama, Tomoki; Kato, Yushi; Murata, Isao; Shimizu, Kikuo; Yamamoto, Takayoshi; Iida, Toshiyuki

    2015-01-01

    A radiophotoluminescence (RPL) light scope is a remote-sensing technique for measuring in situ the radiation dose in an RPL detector placed at a distance. The RPL light scope is mainly composed of an ultraviolet (UV) pulse laser, telescopic lenses, a photomultiplier tube, and camera modules. In a performance test, some RPL detectors were placed at distances up to 30 m and were illuminated with a pulsed UV laser beam. The photoluminescence responses of the RPL detectors were analyzed using this scope. Their radiation doses were determined from the amplitude of the given component of the photoluminescence responses. The RPL readout could be repeated without fading, and its amplitude exhibited good linearity at a dose ranging from 0.1 to 60 Gy. Furthermore, a two-dimensional distribution of radiation dose was obtained by laser scanning on an RPL detector. It was confirmed that the RPL light scope was a useful remote-sensing tool for high-dose dosimetry. - Highlights: • A radiophotoluminescence (RPL) light scope was developed for high-dose dosimetry. • The RPL light scope has high sensitivity and accuracy in high-dose dosimetry. • Two-dimensional radiation dose distribution was obtained by the RPL light scope.

  13. Precision, high dose radiotherapy: helium ion treatment of uveal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, W.M.; Char, D.H.; Quivey, J.M.; Castro, J.R.; Chen, G.T.Y.; Collier, J.M.; Cartigny, A.; Blakely, E.A.; Lyman, J.T.; Zink, S.R.

    1985-02-01

    The authors report on 75 patients with uveal melanoma who were treated by placing the Bragg peak of a helium ion beam over the tumor volume. The technique localizes the high dose region very tightly around the tumor volume. This allows critical structures, such as the optic disc and the macula, to be excluded from the high dose region as long as they are 3 to 4 mm away from the edge of the tumor. Careful attention to tumor localization, treatment planning, patient immobilization and treatment verification is required. With a mean follow-up of 22 months (3 to 60 months) the authors have had only five patients with a local recurrence, all of whom were salvaged with another treatment. Pretreatment visual acuity has generally been preserved as long as the tumor edge is at least 4 mm away from the macula and optic disc. The only serious complication to date has been an 18% incidence of neovascular glaucoma in the patients treated at our highest dose level. Clinical results and details of the technique are presented to illustrate potential clinical precision in administering high dose radiotherapy with charged particles such as helium ions or protons.

  14. Precision, high dose radiotherapy: helium ion treatment of uveal melanoma

    International Nuclear Information System (INIS)

    Saunders, W.M.; Char, D.H.; Quivey, J.M.

    1985-01-01

    The authors report on 75 patients with uveal melanoma who were treated by placing the Bragg peak of a helium ion beam over the tumor volume. The technique localizes the high dose region very tightly around the tumor volume. This allows critical structures, such as the optic disc and the macula, to be excluded from the high dose region as long as they are 3 to 4 mm away from the edge of the tumor. Careful attention to tumor localization, treatment planning, patient immobilization and treatment verification is required. With a mean follow-up of 22 months (3 to 60 months) the authors have had only five patients with a local recurrence, all of whom were salvaged with another treatment. Pretreatment visual acuity has generally been preserved as long as the tumor edge is at least 4 mm away from the macula and optic disc. The only serious complication to date has been an 18% incidence of neovascular glaucoma in the patients treated at our highest dose level. Clinical results and details of the technique are presented to illustrate potential clinical precision in administering high dose radiotherapy with charged particles such as helium ions or protons

  15. Split-Course, High-Dose Palliative Pelvic Radiotherapy for Locally Progressive Hormone-Refractory Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gogna, Nirdosh Kumar, E-mail: kumar_gogna@health.qld.gov.au [Radiation Oncology Services, Mater Centre, Brisbane, Queensland (Australia); Baxi, Siddhartha; Hickey, Brigid; Baumann, Kathryn [Radiation Oncology Services, Mater Centre, Brisbane, Queensland (Australia); Burmeister, Elizabeth [Princess Alexandra Hospital, Brisbane, Queensland (Australia); Holt, Tanya [Radiation Oncology Services, Mater Centre, Brisbane, Queensland (Australia)

    2012-06-01

    Purpose: Local progression, in patients with hormone-refractory prostate cancer, often causes significant morbidity. Pelvic radiotherapy (RT) provides effective palliation in this setting, with most published studies supporting the use of high-dose regimens. The aim of the present study was to examine the role of split-course hypofractionated RT used at our institution in treating this group of patients. Methods and Materials: A total of 34 men with locoregionally progressive hormone-refractory prostate cancer, treated with a split course of pelvic RT (45-60 Gy in 18-24 fractions) between 2000 and 2008 were analyzed. The primary endpoints were the response rate and actuarial locoregional progression-free survival. Secondary endpoints included overall survival, compliance, and acute and late toxicity. Results: The median age was 71 years (range, 53-88). Treatment resulted in an overall initial response rate of 91%, a median locoregional progression-free survival of 43 months, and median overall survival of 28 months. Compliance was excellent and no significant late toxicity was reported. Conclusions: The split course pelvic RT described has an acceptable toxicity profile, is effective, and compares well with other high-dose palliative regimens that have been previously reported.

  16. A prospective randomized study of the efficacy and cost-effectiveness of high and low dose regimens of I-131 treatment in hyperthyroidism.

    Science.gov (United States)

    Pusuwan, Pawana; Tuntawiroon, Malulee; Sritongkul, Nopamol; Chaudakshetrin, Pachee; Nopmaneejumruslers, Cherdchai; Komoltri, Chulalak; Thepamongkhol, Kullathorn; Khiewvan, Benjapa; Tuchinda, Pongpija; Sriussadaporn, Sutin

    2011-03-01

    To compare the efficacy and cost-effectiveness of high and low dose regimens of I-131 treatment in patients with hyperthyroidism. One hundred fifty patients with proven hyperthyroidism were randomly allocated into the high (74 patients) and low (76 patients) dose regimen of I-131 treatment. Four patients of the high dose group and one patient of the low dose group were excluded because of lost follow-up. A gland-specific dosage was calculated on the estimated weight of thyroid gland and 24-hour I-131 uptake. The high and low I-131 dose regimens were 150 microCi/gm and 100 microCi/gm, respectively. The first mean radioiodine activity administered to the high and low dose group was 10.2 and 8 mCi, respectively. Repeated treatment was given to 25 patients of the high dose group and 40 patients of the low dose group. Clinical outcome and calculated costs for outpatient attendances, and laboratory tests together with initial and subsequent treatments were evaluated for one year after I-131 treatment. Elimination of hyperthyroidism that resulted in either euthyroidism or hypothyroidism was classified as therapeutic success. The cost effectiveness was also compared. At 6 months after treatment, 45 (64.3%) patients receiving high dose and 59 (78.7%) patients receiving low dose were hyperthyroidism. Clinical outcome at one year showed persistence of hyperthyroidism in 21 (30%) patients of the high dose regimen and 36 (48%) patients of the low dose regimen. At one year post treatment, it was demonstrated that the high dose regimen could eliminate hyperthyroidism in a significantly shorter time than the low dose regimen, i.e., 259.6 days and 305.5 days, respectively, p = 0.008). For the persistent hyperthyroid patients, the average total cost of treatment in the low dose group was significantly higher than that of the high dose group, i.e., 13,422.78 baht and 10,942.79 baht, respectively; p = 0.050). A high dose regimen of radioactive iodine treatment is more effective than

  17. Neutropenia induced by high-dose intravenous benzylpenicillin in treating neurosyphilis: Does it really matter?

    Directory of Open Access Journals (Sweden)

    Rui-Rui Peng

    2017-03-01

    Full Text Available Prompt therapy with high-dose intravenous benzylpenicillin for a prolonged period is critical for neurosyphilis patients to avoid irreversible sequelae. However, life-threatening neutropenia has been reported as a complication of prolonged therapy with high doses of benzylpenicillin when treating other diseases. This study aimed to investigate the incidence, presentation, management and prognosis of benzylpenicillin-induced neutropenia in treating neurosyphilis based on a large sample of syphilis patients in Shanghai.Between 1st January 2013 and 31st December 2015, 1367 patients with neurosyphilis were treated with benzylpenicillin, 578 of whom were eligible for recruitment to this study. Among patients without medical co-morbidities, the total incidence of benzylpenicillin-induced neutropenia and severe neutropenia was 2.42% (95% CI: 1.38-4.13% and 0.35% (95% CI: 0.06-1.39%, respectively. The treatment duration before onset of neutropenia ranged from 10 to 14 days, with a total cumulative dose of between 240 and 324 megaunits of benzylpenicillin. Neutropenia was accompanied by symptoms of chills and fever (5 patients, fatigue (2 patients, cough (1 patient, sore throat (1 patient, diarrhea (1 patient and erythematous rash (1 patient. The severity of neutropenia was not associated with age, gender or type of neurosyphilis (p>0.05. Neutropenia, even when severe, was often tolerated and normalized within one week. A more serious neutropenia did not occur when reinstituting benzylpenicillin in patients with mild or moderate neutropenia nor when ceftriaxone was used three months after patients had previously experienced severe neutropenia.Benzylpenicillin-induced neutropenia was uncommon in our cohort of patients. Continuation of therapy was possible with intensive surveillance for those with mild or moderate neutropenia. For severe neutropenia, it is not essential to aggressively use hematopoietic growth factors or broad-spectrum antibiotics for

  18. High dose rate brachytherapy for the treatment of soft tissue sarcoma of the extremity

    International Nuclear Information System (INIS)

    Speight, J.L.; Streeter, O.E.; Chawla, S.; Menendez, L.E.

    1996-01-01

    Purpose: we examined the role of preoperative neoadjuvant chemoradiation and adjuvant high-dose rate brachytherapy on the management of prognostically unfavorable soft tissue sarcomas of the extremities. Our goal was to examine the effect of high dose rate interstitial brachytherapy (HDR IBT) on reducing the risk of local recurrence following limb-sparing resection, as well as shortening treatment duration. Materials and methods: eleven patients, ranging in age from 31 to 73 years old, with soft tissue sarcoma of the extremity were treated at USC/Norris Comprehensive Cancer Center during 1994 and 1995. All patients had biopsy proven soft tissue sarcoma, and all were suitable candidates for limb-sparing surgery. All lesions were greater than 5cm in size and were primarily high grade. Tumor histologies included malignant fibrous histiocytoma (45%), liposarcoma (18%) and leiomyosarcoma, synovial cell sarcoma and spindle cell sarcoma (36%). Sites of tumor origin were the lower extremity (55%), upper extremity (18%) and buttock (9%), 1 patient (9%) had lesions in both the upper and lower extremity. Patients received HDR IBT following combined chemotherapy and external beam irradiation (EBRT) and en bloc resection of the sarcoma. Neoadjuvant chemotherapy consisted of three to four cycles of either Ifosfamide/Mesna with or without Adriamycin, or Mesna, Adriamycin, Ifosfamide and Dacarbazine. One patient received Cis-platin in addition to Ifos/Adr. A minimum of two cycles of chemotherapy were administered prior to EBRT. Additional cycles of chemotherapy were completed concurrently with EBRT but prior to HDR IBT. Preoperative EBRT doses ranging from 40 to 59.4 Gy were given in daily fractions of 180 to 200cGy. Following en bloc resection, HDR IBT was administered using the Omnitron tm 2000 remote afterloading system. Doses ranging from 13 to 30 Gy were delivered to the surgical tumor bed at depths of 0.5mm to 0.75mm from the radioactive source. Results: median follow-up was

  19. Successfully Managing Impending Skin Necrosis following Hyaluronic Acid Filler Injection, using High-Dose Pulsed Hyaluronidase

    Directory of Open Access Journals (Sweden)

    Kwok Thye David Loh, MBBS

    2018-02-01

    Full Text Available Summary:. Facial fillers are becoming increasingly popular as aesthetic procedures to temporarily reduce the depth of wrinkles or to contour faces. However, even in the hands of very experienced injectors, there is always a small possibility of vascular complications like intra-arterial injection of filler substance. We present a case report of a patient who developed features of vascular obstruction in right infraorbital artery and tell-tale signs of impending skin necrosis, after hyaluronic acid filler injection by an experienced injector. The diagnosis of a vascular complication was made quickly with the help of clinical features like blanching, livedo reticularis, and poor capillary refill. Patient was treated promptly with “high-dose pulsed hyaluronidase protocol” comprising three 1,000-unit pulses of hyaluronidase, administered hourly. There was no further increase in size of the involved area after the first dose of hyaluronidase. All of the involved area, along with 1 cm overlapping in uninvolved skin area, was injected during each injection pulse, using a combination of cannula and needle. Complete reperfusion and good capillary filling were achieved after completion of 3 pulses, and these were taken as the end-point of high-dose pulsed hyaluronidase treatment. Immediate skin changes after filler injections, as well as after hyaluronidase injections and during the 3-week recovery period, were documented with photographs and clinical notes. Involved skin was found to have been fully recovered from this vascular episode, thus indicating that complete recovery of the ischemic skin changes secondary to possible intra-arterial injection could be achieved using high-dose pulsed hyaluronidase protocol.

  20. High dose vitamin K3 infusion in advanced hepatocellular carcinoma.

    Science.gov (United States)

    Sarin, Shiv K; Kumar, Manoj; Garg, Sanjay; Hissar, Syed; Pandey, Chandana; Sharma, Barjesh C

    2006-09-01

    The survival of patients with unresectable advanced hepatocellular carcinoma (HCC) with portal vein thrombosis is dismal. Current therapeutic options have limited efficacy. Vitamin K has been shown to have antitumor effect on HCC cells both in cell lines and patients with advanced HCC. The aim of this study was to assess the clinical efficacy of high dose vitamin K3 in the treatment of advanced HCC with portal vein thrombosis. Forty-two consecutive patients with advanced HCC (Stage C according to BCLC staging system) with portal vein thrombosis were randomized into two groups: (i) high dose vitamin K3 (n = 23); and (ii) placebo (n = 19). The vitamin K3 was administered by i.v. infusion of 50 mg/day with daily increase of dose by 50 mg for 6 days, followed by 20 mg i.m. twice daily for 2 weeks. Of the 23 patients treated with vitamin K, one (4.3%) achieved complete response and three (13%) partial response, for a total of four (17.4%) objective responders overall. The overall mean survival was 8.9 +/- 8.8 months (median: 6; range 1-37 months) in the vitamin K group and 6.8 +/- 5.3 months (median: 5; range 1.5-21 months) in the placebo group (P = 0.552). The mean duration of survival was longer in patients in the vitamin K group who achieved objective response (22.5 +/- 12.2; median: 21; range 11-37 months) as compared to patients not achieving objective response (6.1 +/- 4.6; median: 5; range 1-16 months) (P = 0.0.002). Portal vein thrombosis resolved with complete patency in one (4.35%) patient. Treatment with high dose vitamin K produces objective response in 17% patients with improved survival in patients achieving objective response; however, it does not affect the overall survival.

  1. Cooperative binding mitigates the high-dose hook effect.

    Science.gov (United States)

    Roy, Ranjita Dutta; Rosenmund, Christian; Stefan, Melanie I

    2017-08-14

    The high-dose hook effect (also called prozone effect) refers to the observation that if a multivalent protein acts as a linker between two parts of a protein complex, then increasing the amount of linker protein in the mixture does not always increase the amount of fully formed complex. On the contrary, at a high enough concentration range the amount of fully formed complex actually decreases. It has been observed that allosterically regulated proteins seem less susceptible to this effect. The aim of this study was two-fold: First, to investigate the mathematical basis of how allostery mitigates the prozone effect. And second, to explore the consequences of allostery and the high-dose hook effect using the example of calmodulin, a calcium-sensing protein that regulates the switch between long-term potentiation and long-term depression in neurons. We use a combinatorial model of a "perfect linker protein" (with infinite binding affinity) to mathematically describe the hook effect and its behaviour under allosteric conditions. We show that allosteric regulation does indeed mitigate the high-dose hook effect. We then turn to calmodulin as a real-life example of an allosteric protein. Using kinetic simulations, we show that calmodulin is indeed subject to a hook effect. We also show that this effect is stronger in the presence of the allosteric activator Ca 2+ /calmodulin-dependent kinase II (CaMKII), because it reduces the overall cooperativity of the calcium-calmodulin system. It follows that, surprisingly, there are conditions where increased amounts of allosteric activator actually decrease the activity of a protein. We show that cooperative binding can indeed act as a protective mechanism against the hook effect. This will have implications in vivo where the extent of cooperativity of a protein can be modulated, for instance, by allosteric activators or inhibitors. This can result in counterintuitive effects of decreased activity with increased concentrations of

  2. Fourteen-day high-dose esomeprazole, amoxicillin and metronidazole as third-line treatment for Helicobacter pylori infection.

    Science.gov (United States)

    Puig, Ignasi; González-Santiago, Jesús M; Molina-Infante, Javier; Barrio, Jesús; Herranz, Maria Teresa; Algaba, Alicia; Castro, Manuel; Gisbert, Javier P; Calvet, Xavier

    2017-09-01

    The efficacy of currently recommended third-line therapies for Helicobacter pylori is suboptimal, even that of culture-guided treatments. Resistance to multiple antibiotics is the major factor related to treatment failure. The aim of this study was to evaluate the effectiveness and safety of a 14-day therapy using high-dose of amoxicillin, metronidazole and esomeprazole. Multicenter open-label study as a register in routine clinical practice in patients with two previous failures of eradication therapy. A triple therapy with esomeprazole 40 mg b.d., amoxicillin 1 g t.d.s and metronidazole 500 mg t.d.s for 2 weeks was administered as a third-line therapy after a first treatment including clarithromycin and a second treatment including a quinolone. Helicobacter pylori status was determined by either histology or 13 C-UBT both before and after treatment. A total of 68 patients were included in this study. An interim analysis showed that only three out of eight patients who had received metronidazole in previous eradication regimens were cured (37%, 95% CI 8-75); as a result, after this interim analysis only metronidazole-naïve patients were included. The ITT eradication rate in metronidazole-naive patients was 64% (95% CI 51-76). Adverse events occurred in 58% of patients, all of them mild-to-moderate. Two patients (3%) did not complete >90% of the treatment because of side effects. No severe adverse events occurred. Cure rates of this 14-day schedule using high-dose esomeprazole, amoxicillin and metronidazole as a third-line eradication regimen were suboptimal, especially in patients who had received metronidazole in previous failed eradication regimens. © 2017 John Wiley & Sons Ltd.

  3. Radiation processing and high-dose dosimetry at ANSTO

    International Nuclear Information System (INIS)

    Gant, G.J.; Saunders, M.; Banos, C.; Mo, L.; Davies, J.; Evans, O.

    2001-01-01

    The Radiation Technology group at ANSTO is part of the Physics Division and provides services and advice in the areas of gamma irradiation and high-dose dosimetry. ANSTO's irradiation facilities are designed for maximum dose uniformity and provide a precision irradiation service unique in Australia. Radiation Technology makes and sells reference and transfer standard dosimeters which are purchased by users and suppliers of commercial irradiation services in Australia and the Asia-Pacific region. A calibration service is also provided for dosimeters purchased from other suppliers

  4. An evaluation of high-dose jobs for ALARA improvement

    International Nuclear Information System (INIS)

    Mun, J. H.; Kim, H. S.

    1997-01-01

    It is well known that about 70 percent of occupational dose have incurred from maintenance jobs at outage period. To reduce occupational dose, first, the high-dose jobs at the outage period should be identified and evaluated. For this, the database program is used, which contains the ORE data of reference plants, Kori Units 3 and 4. As a result, it is found that the jobs related to steam generator are the highest dose jobs in terms of collective ORE dose. From the analysis of the job procedures of those jobs, the ALARA improvements are also derived

  5. Australian high-dose-rate brachytherapy protocols for gynaecological malignancy

    International Nuclear Information System (INIS)

    MacLeod, C.; Dally, M.; Stevens, M.; Thornton, D.; Carruthers, S.; Jeal, P.

    2001-01-01

    There is no consensus over the optimal dose fractionation schedules for high-dose-rate (HDR) brachytherapy used for gynaecological malignancy. In Australian public hospital departments of radiation oncology, HDR brachytherapy for gynaecological cancer is being more commonly used. A survey of public departments that are using this technology, or that plan to introduce this technology, was performed. Their current protocols are presented. In general, protocols are similar biologically; however, the practical aspects such as the number of fractions given do vary and may reflect resource restrictions or, alternatively, differences in interpretations of the literature and of the best protocols by clinicians. Copyright (2001) Blackwell Science Pty Ltd

  6. Prehospital high-dose sublingual nitroglycerin rarely causes hypotension.

    Science.gov (United States)

    Clemency, Brian M; Thompson, Jeffrey J; Tundo, Gina N; Lindstrom, Heather A

    2013-10-01

    High-dose intravenous nitroglycerin is a common in-hospital treatment for respiratory distress due to congestive heart failure (CHF) with hypertension. Intravenous (IV) nitroglycerin administration is impractical in the prehospital setting. In 2011, a new regional Emergency Medical Services (EMS) protocol was introduced allowing advanced providers to treat CHF with high-dose oral nitroglycerin. The protocol calls for patients to be treated with two sublingual tabs (0.8 mg) when systolic blood pressure (SBP) was >160 mm Hg, or three sublingual tabs (1.2 mg) when SBP was >200 mm Hg, every five minutes as needed. Hypothesis/Problem To assess the protocol's safety, the incidence of hypotension following prehospital administration of multiple simultaneous nitroglycerin (MSN) tabs by EMS providers was studied. This study was a retrospective cohort study of patients from a single commercial EMS agency over a 6-month period. Records from patients with at least one administration of MSN were reviewed. For each administration, the first documented vital signs pre- and post-administration were compared. Administrations were excluded if pre- or post-administration vital signs were missing. One hundred case-patients had at least one MSN administration by an advanced provider during the study period. Twenty-five case-patients were excluded due to incomplete vital signs. Seventy-five case-patients with 95 individual MSN administrations were included for analysis. There were 65 administrations of two tabs, 29 administrations of three tabs, and one administration of four tabs. The mean change in SBP following MSN was -14.7 mm Hg (SD = 30.7; range, +59 to -132). Three administrations had documented systolic hypotension in the post-administration vital signs (97/71, 78/50 and 66/47). All three patients were over 65 years old, were administered two tabs, had documented improved respiratory status, and had repeat SBP of at least 100. The incidence of hypotension following MSN

  7. High-dose irradiated food: Current progress, applications, and prospects

    Science.gov (United States)

    Feliciano, Chitho P.

    2018-03-01

    Food irradiation as an established and mature technology has gained more attention in the food industry for ensuring food safety and quality. Primarily used for phytosanitary applications, its use has been expanded for developing various food products for varied purposes (e.g. ready-to-eat & ready-to-cook foods, hospital diets, etc.). This paper summarized and analyzed the recent progress and application of high-dose irradiation and discussed its prospects in the field of food product development, its safety and quality.

  8. Establishment of a dosimetric system for high doses using glasses

    International Nuclear Information System (INIS)

    Correa Quezada, Valeria de la Asuncion

    1997-01-01

    A routine dosimetric system was developed using commercial glass samples. The dosimetric characteristics of national and imported samples were studied: batch uniformity, response repeatability, reutilization, absorbed dose response, detection range, response stability as a function of absorbed dose, storage temperature and thermal treatments pre- and post-irradiation, using the optical absorption technique. As an application, the dosimetric system was tested in a flower irradiation process at IPEN. All the obtained results show the usefulness of the proposed system for high dose dosimetry. (author)

  9. An aCGH classifier derived from BRCA1-mutated breast cancer and benefit of high-dose platinum-based chemotherapy in HER2-negative breast cancer patients

    NARCIS (Netherlands)

    Vollebergh, M. A.; Lips, E. H.; Nederlof, P. M.; Wessels, L. F. A.; Schmidt, M. K.; van Beers, E. H.; Cornelissen, S.; Holtkamp, M.; Froklage, F. E.; de Vries, E. G. E.; Schrama, J. G.; Wesseling, J.; van de Vijver, M. J.; van Tinteren, H.; de Bruin, M.; Hauptmann, M.; Rodenhuis, S.; Linn, S. C.

    Patients and methods: We evaluated this classifier in stage III breast cancer patients, who had been randomly assigned between adjuvant high-dose platinum-based (HD-PB) chemotherapy, a DSB-inducing regimen, and conventional anthracycline-based chemotherapy. Additionally, we assessed BRCA1 loss

  10. The influence of high doses of radiation in citrine stones

    International Nuclear Information System (INIS)

    Teixeira, M. I.; Caldas, L. V. E.

    2014-08-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  11. High-dose contrast-enhanced MRI in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Koudriavtseva, T. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Pozzilli, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Di Biasi, C. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Iannilli, M. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Trasimeni, G. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Gasperini, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Argentino, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Gualdi, G.F. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy)

    1996-05-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs.

  12. TL response of citrine samples for high-dose dosimetry

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2011-01-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the thermoluminescence technique (TL). In this work, the TL properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tectosilicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The citrine stone samples were powdered, and the selected grains were mixed with Teflon in the proportion 2 (Teflon):1 (Citrine). The mixture was pressed and sintered for production of Citrine -Teflon pellets of 50 mg. The TL emission curve showed two peaks at 160 deg C and 220 deg C. To remove the TL peak (160 deg C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The TL dose-response curve between 50 Gy and 100 kGy, the reproducibility of TL response and the lower detection dose were obtained. The preliminary results show that citrine may be useful for high-dose dosimetry. (author)

  13. Spectroscopic gamma camera for use in high dose environments

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Yuichiro, E-mail: yuichiro.ueno.bv@hitachi.com [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Fujishima, Yasutake; Kometani, Yutaka [Hitachi Works, Hitachi-GE Nuclear Energy, Ltd., Hitachi-shi, Ibaraki-ken (Japan); Suzuki, Yasuhiko [Measuring Systems Engineering Dept., Hitachi Aloka Medical, Ltd., Ome-shi, Tokyo (Japan); Umegaki, Kikuo [Faculty of Engineering, Hokkaido University, Sapporo-shi, Hokkaido (Japan)

    2016-06-21

    We developed a pinhole gamma camera to measure distributions of radioactive material contaminants and to identify radionuclides in extraordinarily high dose regions (1000 mSv/h). The developed gamma camera is characterized by: (1) tolerance for high dose rate environments; (2) high spatial and spectral resolution for identifying unknown contaminating sources; and (3) good usability for being carried on a robot and remotely controlled. These are achieved by using a compact pixelated detector module with CdTe semiconductors, efficient shielding, and a fine resolution pinhole collimator. The gamma camera weighs less than 100 kg, and its field of view is an 8 m square in the case of a distance of 10 m and its image is divided into 256 (16×16) pixels. From the laboratory test, we found the energy resolution at the 662 keV photopeak was 2.3% FWHM, which is enough to identify the radionuclides. We found that the count rate per background dose rate was 220 cps h/mSv and the maximum count rate was 300 kcps, so the maximum dose rate of the environment where the gamma camera can be operated was calculated as 1400 mSv/h. We investigated the reactor building of Unit 1 at the Fukushima Dai-ichi Nuclear Power Plant using the gamma camera and could identify the unknown contaminating source in the dose rate environment that was as high as 659 mSv/h.

  14. High-dose contrast-enhanced MRI in multiple sclerosis

    International Nuclear Information System (INIS)

    Koudriavtseva, T.; Pozzilli, C.; Di Biasi, C.; Iannilli, M.; Trasimeni, G.; Gasperini, C.; Argentino, C.; Gualdi, G.F.

    1996-01-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs

  15. Radiation safety program in a high dose rate brachytherapy facility

    International Nuclear Information System (INIS)

    Rodriguez, L.V.; Hermoso, T.M.; Solis, R.C.

    2001-01-01

    The use of remote afterloading equipment has been developed to improve radiation safety in the delivery of treatment in brachytherapy. Several accidents, however, have been reported involving high dose-rate brachytherapy system. These events, together with the desire to address the concerns of radiation workers, and the anticipated adoption of the International Basic Safety Standards for Protection Against Ionizing Radiation (IAEA, 1996), led to the development of the radiation safety program at the Department of Radiotherapy, Jose R. Reyes Memorial Medical Center and at the Division of Radiation Oncology, St. Luke's Medical Center. The radiation safety program covers five major aspects: quality control/quality assurance, radiation monitoring, preventive maintenance, administrative measures and quality audit. Measures for evaluation of effectiveness of the program include decreased unnecessary exposures of patients and staff, improved accuracy in treatment delivery and increased department efficiency due to the development of staff vigilance and decreased anxiety. The success in the implementation required the participation and cooperation of all the personnel involved in the procedures and strong management support. This paper will discuss the radiation safety program for a high dose rate brachytherapy facility developed at these two institutes which may serve as a guideline for other hospitals intending to install a similar facility. (author)

  16. ELDRS Characterization for a Very High Dose Mission

    Science.gov (United States)

    Harris, Richard D.; McClure, Steven S.; Rax, Bernard G.; Kenna, Aaron J.; Thorbourn, Dennis O.; Clark, Karla B.; Yan, Tsun-Yee

    2010-01-01

    Evaluation of bipolar linear parts which may have Enhanced Low Dose Rate Sensitivity (ELDRS) is problematic for missions that have very high dose radiation requirements. The accepted standards for evaluating parts that display ELDRS require testing at a very low dose rate which could be prohibitively long for very high dose missions. In this work, a methodology for ELDRS characterization of bipolar parts for mission doses up to 1 Mrad(Si) is evaluated. The procedure employs an initial dose rate of 0.01 rad(Si)/s to a total dose of 50 krad(Si) and then changes to 0.04 rad(Si)/s to a total dose of 1 Mrad(Si). This procedure appears to work well. No change in rate of degradation with dose has been observed when the dose rate is changed from 0.01 to 0.04 rad(Si)/s. This is taken as an indication that the degradation due to the higher dose rate is equivalent to that at the lower dose rate at the higher dose levels, at least for the parts studied to date. In several cases, significant parameter degradation or functional failure not observed at HDR was observed at fairly high total doses (50 to 250 krad(Si)) at LDR. This behavior calls into question the use of dose rate trend data and enhancement factors to predict LDR performance.

  17. Methodology of high dose research in medical radiodiagnostic

    International Nuclear Information System (INIS)

    Barboza, Adriana E.; Martins, Cintia P. de S.

    2013-01-01

    This work has as main purpose to study occupational exposure in diagnostic radiology in medical cases of high doses recorded in 2011 at the national level . These doses were recorded by monitoring individual of the occupationally exposed individuals (OEI's). This monitoring of the doses received by ionizing radiation has as main objective to ensure that the principle of dose limitation is respected. In this study it were evaluated doses of 372 OEI's radiology in different Brazilian states. Doses were extracted from the database of Sector Management Doses of the Institute for Radioprotection and Dosimetry - IRD/CNEN-RJ, Brazil. The information from the database provide reports of doses from several states, which allows to quantify statistically, showing those with the highest doses in four areas: dose greater than or equal to 20 mSv apron and chest and dose greater than or equal to 100 mSv apron and chest. The identification of these states allows the respective Sanitary Surveillance (VISA), be aware of the events and make plans to reduce them. This study clarified the required procedures when there is a record of high dose emphasizing the importance of using protective radiological equipment, dosimeter and provide a safety environment work by maintaining work equipment. Proposes the ongoing training of professionals, emphasizing the relevance of the concepts of radiation protection and the use of the questionnaire with their investigative systematic sequence, which will allow quickly and efficiently the success the investigations

  18. Dosimetric properties of commercial glasses and sand for high doses

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines

    2004-01-01

    Commercial glasses (transparent and colored) produced by Cebrace, Brazil, Sao Paulo, and sand samples of different Brazilian beaches were studied, due to their low cost and easy handling, to verify the possibility of their use in high dose dosimetry. The main dosimetric characteristics were determined using a densitometer, a spectrophotometer, a thermoluminescent (TL) reader and an electronic paramagnetic resonance system. The gamma irradiations were carried out using a Gamma-Cell 220 and a panoramic source ( 60 Co) of IPEN. An optical absorption band was observed at 420 nm in the glass samples. The TL glow curves presented peaks at 205 deg C, 135 deg C, 150 deg C and 145 deg C for the transparent, bronze, brown and green glass samples, respectively. All EPR spectra of the glasses showed Fe 3+ characteristic signals at g = 4.27 and 2.01. The gamma irradiated sand samples presented two peaks at 110 deg C and 170 deg C and an EPR signal at g= 1.999. However, these materials present a pronounced thermal fading at room temperature after irradiation. With the objective to minimize this thermal fading, both glass and sand samples were submitted to different pre- and post-irradiation thermal treatments. The glass and sand samples showed the possibility of utilization for high dose dosimetry and as Yes/No irradiation detectors. (author)

  19. Multifocal Electroretinography after High Dose Chloroquine Therapy for Malaria

    Directory of Open Access Journals (Sweden)

    Aline Correa de Carvalho

    2013-01-01

    Full Text Available Purpose: To investigate changes in multifocal electroretinography (mfERG parameters associated with high dose chloroquine therapy for treatment of malaria in the Amazonia region of Brazil. Methods: Forty-eight subjects who had received chloroquine treatment for single or multiple malaria infections with a cumulative dose ranging from 1,050 to 27,000mg were included. The control group consisted of 37 healthy aged-matched subjects. Data was collected on amplitude and implicit time of the N1, P1 and N2 waves in the central macular hexagon (R1 and in five concentric rings at different retinal eccentricities (R2-R6. Results: No significant difference was observed in any mfERG parameter between chloroquine treated patients and control subjects. A comparison with previous data obtained from patients with rheumatologic disorders in the same region of Brazil who had received larger cumulative doses of chloroquine and had displayed mfERG changes, indicated that retinal toxicity seems to be dependent on cumulative dose. Conclusion: Lack of mfERG changes in the current study suggests that intensive high dose chloroquine therapy for treatment of malaria is not associated with retinal toxicity.

  20. The influence of high doses of radiation in citrine stones

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, M. I. [Universidade Nove de Julho - UNINOVE, Rua Vergueiro 235/249, 01504-001 Sao Paulo (Brazil); Caldas, L. V. E., E-mail: miteixeira@ipen.br [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ({sup 60}Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO{sub 2}), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  1. Audits in high dose rate brachytherapy in Brazil

    International Nuclear Information System (INIS)

    Marechal, M.H.; Rosa, L.A.; Velasco, A.; Paiva, E. de; Goncalves, M.; Castelo, L.C.

    2002-01-01

    The lack of well established dosimetry protocols for HDR sources is a point of great concern regarding the uniformity of procedures within a particular country. The main objective of this paper is to report the results of an implementation of the audit program in dosimetry of high dose rate brachytherapy sources used by the radiation therapy centers in Brazil. In Brazil, among 169 radiotherapy centers, 35 have HDR brachytherapy systems. This program started in August 2001 and until now eight radiotherapy services were audited. The audit program consists of the visit in loco to each center and the evaluation of the intensity of the source with a well type chamber specially design for HDR 192 Ir sources. The measurements was carried out with a HDR1000PLUS Brachytherapy Well Type Chamber and a MAX 4000 Electrometer, both manufactured by Standard Imaging Inc. The chamber was calibrated in air kerma strength by the Accredited Dosimetry Calibration Laboratory, Department of Medical Physics, University of Wisconsin in the USA. The same chamber was calibrated in Brazil using a 192 lr high dose rate source whose intensity was determined by 60 Co gamma rays and 250 kV x rays interpolation methodology. The Nk of 60 Co and 250 kV x rays were provided by the Brazilian National Standard Laboratory for Ionizing Radiation (LMNRI)

  2. Stock selection of high-dose-irradiation-resistant materials for filter press under high-dose irradiation operation

    International Nuclear Information System (INIS)

    Ishiyama, Shintaro; Minami, Mamoru; Hara, Kouji; Yamashita, Manabu

    2015-01-01

    In a volume reduction process for the decontamination of contained soil, the performance degradation of a filter press is expected owing to material deterioration under high-dose irradiation. Eleven-stock selection of candidate materials including polymers, fibers and rubbers for the filter press was conducted to achieve a high performance of volume reduction of contaminated soil and the following results were derived. Crude rubber and nylon were selected as prime candidates for packing, diaphragm and filter plate materials. Polyethylene was also selected as a prime candidate for the filter cloth material. (author)

  3. GAS SEPARATION MEMBRANES COMPRISING PERMEABILITY ENHANCING ADDITIVES

    NARCIS (Netherlands)

    Wessling, Matthias; Sterescu, D.M.; Stamatialis, Dimitrios

    2007-01-01

    The present invention relates to polymer compositions comprising a (co)polymer comprising (a) an arylene oxide moiety and (b) a dendritic (co)polymer, a hyperbranched (co)polymer or a mixture thereof, and the use of these polymer compositions as membrane materials for the separation of gases. The

  4. Cationic electrodepositable coating composition comprising lignin

    Science.gov (United States)

    Fenn, David; Bowman, Mark P; Zawacky, Steven R; Van Buskirk, Ellor J; Kamarchik, Peter

    2013-07-30

    A cationic electrodepositable coating composition is disclosed. The present invention in directed to a cationic electrodepositable coating composition comprising a lignin-containing cationic salt resin, that comprises (A) the reaction product of: lignin, an amine, and a carbonyl compound; (B) the reaction product of lignin, epichlorohydrin, and an amine; or (C) combinations thereof.

  5. Semiconductor device comprising a pn-heterojunction

    NARCIS (Netherlands)

    2007-01-01

    An electric device is disclosed comprising a pn-heterojunction ( 4 ) formed by a nanowire ( 3 ) of 111 -V semiconductor material and a semiconductor body ( 1 ) comprising a group IV semiconductor material. The nanowire ( 3 ) is positioned in direct contact with the surface ( 2 ) of the semiconductor

  6. Treatment of relapsed or refractory acute leukemia in childhood with bisantrene combined with high dose aracytine.

    Science.gov (United States)

    Leblanc, T; Deméocq, F; Leverger, G; Baruchel, A; Lemerle, S; Vannier, J P; Nelken, B; Guillot, T; Schaison, G

    1994-01-01

    Bisantrene is an anthracene derivative which has demonstrated activity in acute myeloblastic leukemia (AML) and in lymphoma. The present study was designed to assess the reinduction rate and toxicity of bisantrene (250 mg/m2/d x 5) associated with aracytine (100 mg/m2 twice a day x 5) in refractory and relapsed acute childhood leukemia. Patients who relapsed after bone marrow transplantation were eligible. Twenty-six children were included. Diagnoses were as follows: 13 AML, 9 acute lymphoblastic leukemia (ALL), and 4 undifferentiated leukemia (AUL). All patients had been very highly pretreated, especially with anthracyclines, and most of them were of poor prognosis. The overall response rate was 46% with a 95% confidence interval ranging from 27-65%. According to diagnosis, complete remission (CR) rates are: AML: 5/13, ALL: 5/9, and AUL: 2/4. Four children died, three from infection and one from acute lysis syndrome. The major toxicity was infection with grade 3 and 4 episodes occurring in 42% of patients. No significant cardiac toxicity was noted. Hepatic and renal toxicity was noted. Hepatic and renal toxicity were limited and transient. Bisantrene in association with aracytine is effective in both AML and ALL of childhood. Bisantrene should be evaluated with a five-day schedule in other pediatric malignancies. In children with acute leukemia previously treated with high dose aracytine, new combination regimen is warranted.

  7. Escalation to High Dose Defibrotide in Patients with Hepatic Veno-Occlusive Disease

    Science.gov (United States)

    Triplett, Brandon M.; Kuttab, Hani I.; Kang, Guolian; Leung, Wing

    2015-01-01

    Hepatic veno-occlusive disease (VOD) is a serious complication of high-dose chemotherapy regimens, such as those utilized in hematopoietic cell transplantation recipients. Defibrotide is considered a safe and effective treatment when dosed at 25 mg/kg/day. However, patients who develop VOD still have increased mortality despite the use of defibrotide. Data are limited on the use of doses above 60 mg/kg/day for persistent VOD. In this prospective clinical trial, 34 patients received escalating doses of defibrotide. For patients with persistent VOD despite doses of 60 mg/kg/day, doses were increased to a maximum of 110 mg/kg/day. There was no observed increase in toxicity until doses rose beyond 100 mg/kg/day. Patients receiving doses between 10–100 mg/kg/day experienced an average of 3 bleeding episodes per 100 days of treatment, while those receiving doses >100 mg/kg/day experienced 13.2 bleeding episodes per 100 days (p=0.008). Moreover, dose reductions due to toxicity were needed at doses of 110 mg/kg/day more often than at lower doses. Defibrotide may be safely escalated to doses well above the current standard without an increase in bleeding risk. However, the efficacy of this dose escalation strategy remains unclear, as outcomes were similar to published cohorts of patients receiving standard doses of defibrotide for VOD. PMID:26278046

  8. Escalation to High-Dose Defibrotide in Patients with Hepatic Veno-Occlusive Disease.

    Science.gov (United States)

    Triplett, Brandon M; Kuttab, Hani I; Kang, Guolian; Leung, Wing

    2015-12-01

    Hepatic veno-occlusive disease (VOD) is a serious complication of high-dose chemotherapy regimens, such as those used in hematopoietic cell transplantation recipients. Defibrotide is considered a safe and effective treatment when dosed at 25 mg/kg/day. However, patients who develop VOD still have increased mortality despite the use of defibrotide. Data are limited on the use of doses above 60 mg/kg/day for persistent VOD. In this prospective clinical trial 34 patients received escalating doses of defibrotide. For patients with persistent VOD despite doses of 60 mg/kg/day, doses were increased to a maximum of 110 mg/kg/day. Increased toxicity was not observed until doses rose beyond 100 mg/kg/day. Patients receiving doses between 10 and 100 mg/kg/day experienced an average of 3 bleeding episodes per 100 days of treatment, whereas those receiving doses >100 mg/kg/day experienced 13.2 bleeding episodes per 100 days (P = .008). Moreover, dose reductions due to toxicity were needed at doses of 110 mg/kg/day more often than at lower doses. Defibrotide may be safely escalated to doses well above the current standard without an increase in bleeding risk. However, the efficacy of this dose-escalation strategy remains unclear, because outcomes were similar to published cohorts of patients receiving standard doses of defibrotide for VOD. Copyright © 2015 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  9. High Doses Gamma Radiolysis of PVC: Mechanisms of Degradation

    International Nuclear Information System (INIS)

    Colombani, J.

    2006-01-01

    PVC radiolysis leads to the formation of various degradation products: radicals, gas, oxidized products or polyenes. In order to predict the formation of the degradation products with regard to irradiation and ageing parameters, it is important to improve the understanding of the radiolysis mechanisms of PVC. Thus, we used several analytical techniques (Electron Spin Resonance, Fourier Transform Infrared spectroscopy, Nuclear Magnetic Resonance, Size Exclusion Chromatography) to get information on PVC samples irradiated at high doses (up to 4MGy) under different conditions. Gamma irradiation induces the formation of various radicals into PVC. Older studies were generally focused on the effect of low dose and/or low temperature irradiations on PVC. We present here ESR signals of PVC irradiated at high doses and at room temperature. We show that peroxyl radicals are producted by radiolysis under aerobe conditions and that polyenyl radicals are formed under anaerobe conditions. PVC radiolysis induces gas production and especially hydrogen chloride. Production of hydrogen chloride is well known until 1 MGy. We have studied by FTIR, the evolution of the quantity of HCl produced until 4 MGy. We show that higher irradiation dose leads to the lower radiolytic yield of HCl (G(HCl)). Moreover, G(HCl) obtained in aerobe conditions is about fourfold as great as G(HCl) observed in anaerobe radiolysis. Propagation and termination reactions induce degradation products: polyene sequences and crosslinking reactions are observed under anaerobe conditions; oxidized products with addition of chain scissions are formed under aerobe conditions. Although the literature about PVC radiolysis is rich, the main reacting pathways are not well established. Moreover the high doses studies are almost non-existent. We show by FTIR that aerobe radiolysis induces formation of ketons and acids. NMR experiments confirme these results but also focuse on small acids formed (with 2, 3 or 4 carbons). The

  10. High-dose radioiodine therapy of Graves disease

    International Nuclear Information System (INIS)

    Solodky, V.; Fomin, D.; Pestritskaya, E.

    2015-01-01

    Full text of publication follows. Objectives: to estimate the effectiveness and safety of the disease treatment under different modes of applying RIT. Materials and methods: 67 patients with the thyrotoxicosis condition associated with Graves disease were researched. The patients were divided into 2 groups: a control group with 25 people (18 women and 7 men), who underwent a low-dose therapy of 150-500 MBq; and a main group of 42 people (32 women and 10 men), who underwent a high-dose therapy of 550 and 800 MBq. The volume of thyroid prior to the treatment made up 23.8 ± 20 ml in the main group and 30.2 ± 23 ml in the control one. The average age in the high-dose group was 44.6 ±23 years old and in the low-dose -47.2 ± 24 years old. In terms of the hormone level before the RIT, 52% of the main group patients experienced euthyroidism, while 48% - thyrotoxicosis. The corresponding indices in the control group were 42% and 58% respectively. The cessation of the thyreostatic therapy came on 5. to 21. day prior to the treatment, with the average of 14 ±7 days in both groups. The diagnosis of the disease was based on ultrasonography, planar scintigraphy, the hormone level and antibody titer. The performance was assessed through the attainment of hypo-thyrosis and the transition to a substitutive hormonal therapy with L-thyroxine in 6 months or more. The attainment of euthyroidism was seen as a partial effect due to a possibility of relapse. Results: in 6 months a positive result in the form of hypo-thyrosis was achieved for 39 patients in the main group, which accounted for 93%, and 3 patients (7%) experienced euthyroidism. No symptomatic thyrotoxicosis relapses were revealed. In the control group, hypo-thyrosis was achieved by 18 patients, which accounted for 72%; euthyroidism came up to 12%; 4 patients needed a refresher course of RIT, which made up 16% of the group. 93% of the main group patients tolerated the treatment favourably. 3 patients complained of the

  11. Routine quality control of high dose rate brachytherapy equipment

    International Nuclear Information System (INIS)

    Guzman Calcina, Carmen S.; Almeida, Adelaide de; Rocha, Jose R. Oliveira

    2001-01-01

    A Quality Assurance program should be installed also for High Dose Rate brachytherapy, in the order to achieve a correct dose administration to the patient and for the safety to those involved directly with the treatment. The work presented here has the following purposes: Analyze the types of equipment tests presented by the official protocols (TG40, TG56 e ARCAL XXX), evaluate the brachytherapy routine tests of protocols from various national and international radiotherapy services and compare the latter with those presented in the official protocols. As a result, we conclude the following: TG56 presents a higher number of tests when compared to the other official protocols and most of the tests presented by the analyzed services are present in TG56. A suggestion for a basic protocol is presented, emphasizing the periodicity and tolerance level of each of the tests. (author)

  12. Surface sputtering in high-dose Fe ion implanted Si

    International Nuclear Information System (INIS)

    Ishimaru, Manabu

    2007-01-01

    Microstructures and elemental distributions in high-dose Fe ion implanted Si were characterized by means of transmission electron microscopy and Rutherford backscattering spectroscopy. Single crystalline Si(0 0 1) substrates were implanted at 350 deg. C with 120 keV Fe ions to fluences ranging from 0.1 x 10 17 to 4.0 x 10 17 /cm 2 . Extensive damage induced by ion implantation was observed inside the substrate below 1.0 x 10 17 /cm 2 , while a continuous iron silicide layer was formed at 4.0 x 10 17 /cm 2 . It was found that the spatial distribution of Fe projectiles drastically changes at the fluence between 1.0 x 10 17 and 4.0 x 10 17 /cm 2 due to surface sputtering during implantation

  13. measurement of high dose radiation using yellow perspex dosimeter

    International Nuclear Information System (INIS)

    Thamrin, M Thoyib; Sofyan, Hasnel

    1996-01-01

    Measurement of high dose radiation using yellow perspex dosemeter has been carried out. Dose range used was between 0.1 to 3.0 kGy. Measurement of dose rate against Fricke dosemeter as a standard dose meter From the irradiation of Fricke dosemeter with time variation of 3,6,9,12,15 and 18 minute, it was obtained average dose rate of 955.57 Gy/hour, linear equation of dose was Y= 2.333+15.776 X with its correlation factor r = 0.9999. Measurement result using yellow perspex show that correlation between net optical density and radiation dose was not linear with its equation was ODc exp. [Bo + In(dose).Bi] Value of Bo = -0.215 and Bi=0.5020. From the experiment it was suggested that routine dosimeter (yellow perspex) should be calibrated formerly against standard dosemeters

  14. High Fidelity Ion Beam Simulation of High Dose Neutron Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Was, Gary; Wirth, Brian; Motta, Athur; Morgan, Dane; Kaoumi, Djamel; Hosemann, Peter; Odette, Robert

    2018-04-30

    Project Objective: The objective of this proposal is to demonstrate the capability to predict the evolution of microstructure and properties of structural materials in-reactor and at high doses, using ion irradiation as a surrogate for reactor irradiations. “Properties” includes both physical properties (irradiated microstructure) and the mechanical properties of the material. Demonstration of the capability to predict properties has two components. One is ion irradiation of a set of alloys to yield an irradiated microstructure and corresponding mechanical behavior that are substantially the same as results from neutron exposure in the appropriate reactor environment. Second is the capability to predict the irradiated microstructure and corresponding mechanical behavior on the basis of improved models, validated against both ion and reactor irradiations and verified against ion irradiations. Taken together, achievement of these objectives will yield an enhanced capability for simulating the behavior of materials in reactor irradiations

  15. High-dose erythropoietin in patients with progressive multiple sclerosis

    DEFF Research Database (Denmark)

    Schreiber, Karen; Magyari, Melinda; Sellebjerg, Finn

    2017-01-01

    BACKGROUND: Erythropoietin (EPO) is a part of an endogenous neuroprotective system in the brain and may address pathophysiological mechanisms in progressive multiple sclerosis (MS). OBJECTIVE: To evaluate a treatment effect of EPO on progressive MS. METHODS: This was a single-center, randomized......, double-blind, placebo-controlled phase 2 trial, in which 52 patients with secondary or primary progressive MS were allocated to treatment with recombinant EPO (48,000 IU) or placebo, administered intravenously 17 times during 24 weeks. Patients had an Expanded Disability Status Score (EDSS) from 4 to 6......: This study provides class II evidence that treatment with high-dose EPO is not an effective treatment in patients with moderately advanced progressive MS....

  16. Safety handling manual for high dose rate remote afterloading system

    International Nuclear Information System (INIS)

    1999-01-01

    This manual is mainly for safety handling of 192 Ir-RALS (remote afterloading system) of high dose rate and followings were presented: Procedure and document format for the RALS therapy and for handling of its radiation source with the purpose of prevention of human errors and unexpected accidents, Procedure for preventing errors occurring in the treatment schedule and operation, and Procedure and format necessary for newly introducing the system into a facility. Consistency was intended in the description with the quality assurance guideline for therapy with small sealed radiation sources made by JASTRO (Japan Society for Therapeutic Radiology and Oncology). Use of the old type 60 Co-RALS was pointed out to be a serious problem remained and its safety handling procedure was also presented. (K.H.)

  17. Pharmacokinetics of high-dose intravenous melatonin in humans

    DEFF Research Database (Denmark)

    Andersen, Lars P H; Werner, Mads U; Rosenkilde, Mette Marie

    2016-01-01

    This crossover study investigated the pharmacokinetics and adverse effects of high-dose intravenous melatonin. Volunteers participated in 3 identical study sessions, receiving an intravenous bolus of 10 mg melatonin, 100 mg melatonin, and placebo. Blood samples were collected at baseline and 0, 60......, 120, 180, 240, 300, 360, and 420 minutes after the bolus. Quantitative determination of plasma melatonin concentrations was performed using a radioimmunoassay technique. Pharmacokinetic parameters were estimated by a compartmental pharmacokinetic analysis. Adverse effects included assessments...... of sedation and registration of other symptoms. Sedation, evaluated as simple reaction times, was measured at baseline and 120, 180, 300, and 420 minutes after the bolus. Twelve male volunteers completed the study. Median (IQR) Cmax after the bolus injections of 10 mg and 100 mg of melatonin were 221...

  18. Calibration of {sup 192}Ir high dose rate brachytherapy sources

    Energy Technology Data Exchange (ETDEWEB)

    Marechal, M H [Instituto de Radioprotecao e Dozimetria, Rio de Jainero (Brazil); Almeida, C.E. de [Laboratorio de Ciencias Radiologicas, UERL, Rio de Janeiro (Brazil); Sibata, C H [Roswell Park Cancer Inst., Buffalo, NY (United States)

    1996-08-01

    A method for calibration of high dose rate sources used in afterloading brachytherapy systems is described. The calibration for {sup 192}Ir is determined by interpolating {sup 60}Co gamma-rays and 250 kV x-rays calibration factors. All measurements were done using the same build up caps as described by Goetsch et al and recommended by AAPM. The attenuation correction factors were determined to be 0.9903, 0.9928 and 0.9993 for {sup 192}Ir, {sup 60}Co and 250 kV x-ray, respectively. A wall + cap thickness of 0.421 g.cm{sup -2} is recommended for all measurements to ensure electronic equilibrium for {sup 60}Co and {sup 192}Ir gamma-ray beams. A mathematical formalism is described for determination of (N{sub x}){sub Ir}. (author). 5 refs, 1 fig.

  19. Assessments for high dose radionuclide therapy treatment planning

    International Nuclear Information System (INIS)

    Fisher, D.R.

    2003-01-01

    Advances in the biotechnology of cell specific targeting of cancer and the increased number of clinical trials involving treatment of cancer patients with radiolabelled antibodies, peptides, and similar delivery vehicles have led to an increase in the number of high dose radionuclide therapy procedures. Optimised radionuclide therapy for cancer treatment is based on the concept of absorbed dose to the dose limiting normal organ or tissue. The limiting normal tissue is often the red marrow, but it may sometimes be the lungs, liver, intestinal tract, or kidneys. Appropriate treatment planning requires assessment of radiation dose to several internal organs and tissues, and usually involves biodistribution studies in the patient using a tracer amount of radionuclide bound to the targeting agent and imaged at sequential timepoints using a planar gamma camera. Time-activity curves are developed from the imaging data for the major organ tissues of concern, for the whole body and sometimes for selected tumours. Patient specific factors often require that dose estimates be customised for each patient. In the United States, the Food and Drug Administration regulates the experimental use of investigational new drugs and requires 'reasonable calculation of radiation absorbed dose to the whole body and to critical organs' using the methods prescribed by the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine. Review of high dose studies shows that some are conducted with minimal dosimetry, that the marrow dose is difficult to establish and is subject to large uncertainties. Despite the general availability of software, internal dosimetry methods often seem to be inconsistent from one clinical centre to another. (author)

  20. Comparative study of SOI/Si hybrid substrates fabricated using high-dose and low-dose oxygen implantation

    International Nuclear Information System (INIS)

    Dong Yemin; Chen Meng; Chen Jing; Wang Xiang; Wang Xi

    2004-01-01

    Hybrid substrates comprising both silicon-on-insulator (SOI) and bulk Si regions have been fabricated using the technique of patterned separation by implantation of oxygen (SIMOX) with high-dose (1.5 x 10 18 cm -2 ) and low-dose ((1.5-3.5) x 10 17 cm -2 ) oxygen ions, respectively. Cross-sectional transmission electron microscopy (XTEM) was employed to examine the microstructures of the resulting materials. Experimental results indicate that the SOI/Si hybrid substrate fabricated using high-dose SIMOX is of inferior quality with very large surface height step and heavily damaged transitions between the SOI and bulk regions. However, the quality of the SOI/Si hybrid substrate is enhanced dramatically by reducing the implant dose. The defect density in transitions is reduced considerably. Moreover, the expected surface height difference does not exist and the surface is exceptionally flat. The possible mechanisms responsible for the improvements in quality are discussed

  1. Composition comprising lignin and antidi arrheal component

    DEFF Research Database (Denmark)

    2008-01-01

    The present invention relates to a composition comprising lignin and at least one compound selected from the group consisting of bromelain, papain, tannin, carvacrol, thymol, alliin, allicin, fenugreek seed, egg, poppy, poppy seeds, humic acid, roots, kaolin, catechu, cellulase, flavonoid...

  2. High-dose MeV electron irradiation of Si-SiO2 structures implanted with high doses Si+

    Science.gov (United States)

    Kaschieva, S.; Angelov, Ch; Dmitriev, S. N.

    2018-03-01

    The influence was studied of 22-MeV electron irradiation on Si-SiO2 structures implanted with high-fluence Si+ ions. Our earlier works demonstrated that Si redistribution is observed in Si+-ion-implanted Si-SiO2 structures (after MeV electron irradiation) only in the case when ion implantation is carried out with a higher fluence (1016 cm-2). We focused our attention on the interaction of high-dose MeV electron irradiation (6.0×1016 cm-2) with n-Si-SiO2 structures implanted with Si+ ions (fluence 5.4×1016 cm-2 of the same order magnitude). The redistribution of both oxygen and silicon atoms in the implanted Si-SiO2 samples after MeV electron irradiation was studied by Rutherford back-scattering (RBS) spectroscopy in combination with a channeling technique (RBS/C). Our results demonstrated that the redistribution of oxygen and silicon atoms in the implanted samples reaches saturation after these high doses of MeV electron irradiation. The transformation of amorphous SiO2 surface into crystalline Si nanostructures (after MeV electron irradiation) was evidenced by atomic force microscopy (AFM). Silicon nanocrystals are formed on the SiO2 surface after MeV electron irradiation. The shape and number of the Si nanocrystals on the SiO2 surface depend on the MeV electron irradiation, while their size increases with the dose. The mean Si nanocrystals height is 16-20 nm after irradiation with MeV electrons at the dose of 6.0×1016 cm-2.

  3. Evaluation of an every-other-day palonosetron schedule to control emesis in multiple-day high-dose chemotherapy.

    Science.gov (United States)

    Mirabile, Aurora; Celio, Luigi; Magni, Michele; Bonizzoni, Erminio; Gianni, Alessandro Massimo; Di Nicola, Massimo

    2014-12-01

    Efficacy of intermittent palonosetron dosing in patients undergoing multiple-day, high-dose chemotherapy (HDC) was investigated. Fifty-eight patients received palonosetron (0.25 mg intravenous [iv.]) every other day plus daily dexamethasone (8 mg iv. twice daily) dosing. The primary end point was complete control (CC; no emesis, no rescue anti-emetics, and no more than mild nausea) in the overall acute-period (until 24 h after chemotherapy completion). Acute-period CC occurred in 81% and 50% of patients receiving palonosetron and ondansetron (historical control cohort), respectively. Palonosetron (odds ratio [OR]: 4.37; p = 0.001) and a longer duration of HDC regimen (OR: 3.47; p = 0.011) independently predicted a better anti-emetic outcome. Palonosetron every other day plus daily dexamethasone is an effective anti-emetic coverage in patients undergoing HDC.

  4. High dose rate brachytherapy for superficial cancer of the esophagus

    International Nuclear Information System (INIS)

    Maingon, Philippe; D'Hombres, Anne; Truc, Gilles; Barillot, Isabelle; Michiels, Christophe; Bedenne, Laurent; Horiot, Jean Claude

    2000-01-01

    Purpose: We analyzed our experience with external radiotherapy, combined modality treatment, or HDR brachytherapy alone to limited esophageal cancers. Methods and Materials: From 1991 to 1996, 25 patients with limited superficial esophagus carcinomas were treated by high dose rate brachytherapy. The mean age was 63 years (43-86 years). Five patients showed superficial local recurrence after external radiotherapy. Eleven patients without invasion of the basal membrane were staged as Tis. Fourteen patients with tumors involving the submucosa without spreading to the muscle were staged as T1. Treatment consisted of HDR brachytherapy alone in 13 patients, external radiotherapy and brachytherapy in 8 cases, and concomitant chemo- and radiotherapy in 4 cases. External beam radiation was administered to a total dose of 50 Gy using 2 Gy daily fractions in 5 weeks. In cases of HDR brachytherapy alone (13 patients), 6 applications were performed once a week. Results: The mean follow-up is 31 months (range 24-96 months). Twelve patients received 2 applications and 13 patients received 6 applications. Twelve patients experienced a failure (48%), 11/12 located in the esophagus, all of them in the treated volume. One patient presented an isolated distant metastasis. In the patients treated for superficial recurrence, 4/5 were locally controlled (80%) by brachytherapy alone. After brachytherapy alone, 8/13 patients were controlled (61%). The mean disease-free survival is 14 months (1-36 months). Overall survival is 76% at 1 year, 37% at 2 years, and 14% at 3 years. Overall survival for Tis patients is 24% vs. 20% for T1 (p 0.83). Overall survival for patients treated by HDR brachytherapy alone is 43%. One patient presented with a fistula with local failure after external radiotherapy and brachytherapy. Four stenosis were registered, two were diagnosed on barium swallowing without symptoms, and two required dilatations. Conclusion: High dose rate brachytherapy permits the treating

  5. High-dose metoclopramide + lorazepam versus low-dose metoclopramide + lorazepam + dehydrobenzperidol in the treatment of cisplatin-induced nausea and vomiting

    DEFF Research Database (Denmark)

    Herrstedt, Jørn; Hannibal, J; Hallas, Jesper

    1991-01-01

    In a randomized double-blind, cross-over trial of 34 patients receiving cisplatin-based chemotherapy (20-100 mg/m2), the antiemetic effect of high-dose metoclopramide (HDM) (10 mg/kg iv. loading dose + 7 hours continuous infusion) + lorazepam (L) (2.5 mg x 4 po) was compared with low......-dose metoclopramide (LDM) (70 mg) + L (2.5 mg x 2 po) + dehydrobenzperidol (5 mg x 2 im). Among the 29 patients who completed the cross-over, HDM significantly reduced the number of vomiting episodes (p = 0.002) and the degree of nausea (p = 0.004). Seventeen patients preferred the HDM and 4 the LDM regimen (p = 0.......01). Sedation was seen in all but 1 patient, and was graded as severe in 6 patients receiving the HDM and in 2 patients receiving the LDM regimen. No extrapyramidal adverse reactions were seen. We conclude that high-dose metoclopramide + lorazepam is a safe antiemetic regimen and significantly superior to low...

  6. Busulfan and melphalan versus carboplatin, etoposide, and melphalan as high-dose chemotherapy for high-risk neuroblastoma (HR-NBL1/SIOPEN): an international, randomised, multi-arm, open-label, phase 3 trial.

    Science.gov (United States)

    Ladenstein, Ruth; Pötschger, Ulrike; Pearson, Andrew D J; Brock, Penelope; Luksch, Roberto; Castel, Victoria; Yaniv, Isaac; Papadakis, Vassilios; Laureys, Geneviève; Malis, Josef; Balwierz, Walentyna; Ruud, Ellen; Kogner, Per; Schroeder, Henrik; de Lacerda, Ana Forjaz; Beck-Popovic, Maja; Bician, Pavel; Garami, Miklós; Trahair, Toby; Canete, Adela; Ambros, Peter F; Holmes, Keith; Gaze, Mark; Schreier, Günter; Garaventa, Alberto; Vassal, Gilles; Michon, Jean; Valteau-Couanet, Dominique

    2017-04-01

    High-dose chemotherapy with haemopoietic stem-cell rescue improves event-free survival in patients with high-risk neuroblastoma; however, which regimen has the greatest patient benefit has not been established. We aimed to assess event-free survival after high-dose chemotherapy with busulfan and melphalan compared with carboplatin, etoposide, and melphalan. We did an international, randomised, multi-arm, open-label, phase 3 cooperative group clinical trial of patients with high-risk neuroblastoma at 128 institutions in 18 countries that included an open-label randomised arm in which high-dose chemotherapy regimens were compared. Patients (age 1-20 years) with neuroblastoma were eligible to be randomly assigned if they had completed a multidrug induction regimen (cisplatin, carboplatin, cyclophosphamide, vincristine, and etoposide with or without topotecan, vincristine, and doxorubicin) and achieved an adequate disease response. Patients were randomly assigned (1:1) to busulfan and melphalan or to carboplatin, etoposide, and melphalan by minimisation, balancing age at diagnosis, stage, MYCN amplification, and national cooperative clinical group between groups. The busulfan and melphalan regimen comprised oral busulfan (150 mg/m 2 given on 4 days consecutively in four equal doses); after Nov 8, 2007, intravenous busulfan was given (0·8-1·2 mg/kg per dose for 16 doses according to patient weight). After 24 h, an intravenous melphalan dose (140 mg/m 2 ) was given. Doses of busulfan and melphalan were modified according to bodyweight. The carboplatin, etoposide, and melphalan regimen consisted of carboplatin continuous infusion of area under the plasma concentration-time curve 4·1 mg/mL per min per day for 4 days, etoposide continuous infusion of 338 mg/m 2 per day for 4 days, and melphalan 70 mg/m 2 per day for 3 days, with doses for all three drugs modified according to bodyweight and glomerular filtration rate. Stem-cell rescue was given after the last dose of

  7. Cancer-Associated Fibroblasts from lung tumors maintain their immuno-suppressive abilities after high-dose irradiation

    Directory of Open Access Journals (Sweden)

    Laia eGorchs

    2015-05-01

    Full Text Available Accumulating evidence supports the notion that high-dose (>5 Gy radiotherapy (RT regimens are triggering stronger pro-immunogenic effects than standard low-dose (2 Gy regimens. However, the effects of RT on certain immunoregulatory elements in tumors remain unexplored. In this study we have investigated the effects of high-dose irradiation (HD-RT on the immunomodulating functions of cancer-associated fibroblasts (CAFs. Primary CAF cultures were established from lung cancer specimens derived from patients diagnosed for non-small cell lung cancer. Irradiated and non-irradiated CAFs were examined for immunomodulation in experiments with peripheral blood mononuclear cells from random, healthy donors. Regulation of lymphocytes behavior was checked by lymphocyte proliferation assays, lymphocyte migration assays and T-cell cytokine production. Additionally, CAF-secreted immuno-regulatory factors were studied by multiplex protein arrays, ELISAs and by LC-MS/MS proteomics. In all functional assays we observed a powerful immuno-suppressive effect exerted by CAF-conditioned medium on activated T-cells (p>0,001, and this effect was sustained after a single radiation dose of 18 Gy. Relevant immuno-suppressive molecules such as prostaglandin E2, interleukin-6 and -10, or transforming growth factor-β were found in CAF conditioned medium, but their secretion was unchanged after irradiation. Finally, immunogenic cell death responses in CAFs were studied by exploring the release of high motility group box-1 and ATP. Both alarmins remained undetectable before and after irradiation. In conclusion, CAFs play a powerful immuno-suppressive effect over activated T-cells, and this effect remains unchanged after HD-RT. Importantly, CAFs do not switch on immunogenic cell death responses after exposure to HD-RT.

  8. High dose implantations of antimony for buried layer applications

    International Nuclear Information System (INIS)

    Gailliard, J.P.; Dupuy, M.; Garcia, M.; Roussin, J.C.

    1978-01-01

    Electrical and physical properties of high dose implantations of antimony in silicon have been studied for use in buried layer applications. The results have been obtained both on and oriented silicon wafers. Following implantations which lead to amorphization we perform an annealing at 600 0 C for 10 mn in order to recrystallize the layer. The observed electrical properties (μ, R) show that the concentration of electrically active antimony ions is greater than that predicted from the solubility of antimony in silicon. Further annealing (in the range 1050 0 - 1200 0 ) induces: firstly a precipitation of the Sb and secondly a diffusion and dissolution of the precipitates. There is a different evolution of the defects in the and silicon slices. T.E.M. reveals no defects in the wafers after one hour annealing at 1200 0 C, whereas defects and twins remain in wafers. Having obtained the evolution of R with time and temperature it is then determined the implantation and annealing conditions which lead to the low resistivity (R = 10) needed for buried layer applications. Results with very many industrially made devices are discussed

  9. Optimized dose distribution of a high dose rate vaginal cylinder

    International Nuclear Information System (INIS)

    Li Zuofeng; Liu, Chihray; Palta, Jatinder R.

    1998-01-01

    Purpose: To present a comparison of optimized dose distributions for a set of high-dose-rate (HDR) vaginal cylinders calculated by a commercial treatment-planning system with benchmark calculations using Monte-Carlo-calculated dosimetry data. Methods and Materials: Optimized dose distributions using both an isotropic and an anisotropic dose calculation model were obtained for a set of HDR vaginal cylinders. Mathematical optimization techniques available in the computer treatment-planning system were used to calculate dwell times and positions. These dose distributions were compared with benchmark calculations with TG43 formalism and using Monte-Carlo-calculated data. The same dwell times and positions were used for a quantitative comparison of dose calculated with three dose models. Results: The isotropic dose calculation model can result in discrepancies as high as 50%. The anisotropic dose calculation model compared better with benchmark calculations. The differences were more significant at the apex of the vaginal cylinder, which is typically used as the prescription point. Conclusion: Dose calculation models available in a computer treatment-planning system must be evaluated carefully to ensure their correct application. It should also be noted that when optimized dose distribution at a distance from the cylinder surface is calculated using an accurate dose calculation model, the vaginal mucosa dose becomes significantly higher, and therefore should be carefully monitored

  10. Shelf-stable food through high dose irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Placek, V. E-mail: pla@ujv.cz; Svobodova, V.; Bartonicek, B.; Rosmus, J.; Camra, M

    2004-10-01

    Irradiation of food with high doses (radappertization) is a way, how to prepare shelf-stable ready-to-eat food. The radappertization process requires that the food be heated at first to an internal temperature of at least 75 deg. C to inactivate autolytic enzyme, which could cause the spoilage during storage without refrigeration. In order to prevent radiation induced changes in sensory properties (off flavors, odors, undesirable color change, etc.) the food was vacuum packed and irradiated in frozen state at -30 deg. C or less to a minimum dose of 35 kGy. Such products have characteristics of fresh food prepared for eating even if they are stored for long time under tropical conditions. The wholesomeness (safety for consumption) has been confirmed during 40 years of testing. Within the NRI Rez 10 kinds of shelf-stable meat products have been prepared. The meat was cooked, vacuum packed in SiO{sub x}-containing pouch, freezed in liquid nitrogen and irradiated with electron beam accelerator. The microbial, chemical, and organoleptic properties have been tested.

  11. High-dose processing and application to Korean space foods

    Energy Technology Data Exchange (ETDEWEB)

    Song, Beom-Seok; Park, Jin-Gyu; Park, Jae-Nam; Han, In-Jun; Choi, Jong-il [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Kim, Jae-Hun [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Korea Astronaut Project Division, Korea Aerospace Research Institute, Daejeon 305-333 (Korea, Republic of); Byun, Myung-Woo [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Kang, Sang-Wook; Choi, Gi-Hyuk [Korea Astronaut Project Division, Korea Aerospace Research Institute, Daejeon 305-333 (Korea, Republic of); Lee, Ju-Woon [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of)], E-mail: sjwlee@kaeri.re.kr

    2009-07-15

    Nutrition bar, Ramen (ready-to-cook noodle), and two Korean traditional foods (Kimchi, fermented vegetable; Sujeonggwa, cinnamon beverage) have been developed as space foods using high-dose gamma irradiation. Addition of calcium lactate and vitamin C, a mild heating, deep-freezing, and gamma irradiation at 25 kGy were conducted to prepare Kimchi as a ready-to-eat space food. Sterilization of Space Kimchi (SK) was confirmed by a microbiological test. The hardness of the Space Kimchi was lower than the untreated Kimchi (CON), but higher than the irradiated only Kimchi. Sensory attributes of the SK were similar to CON, and maintained during preservation at 35 {sup o}C for 30 days. The optimal doses for eliminating the contaminated microbes and maintaining the qualities of the Nutrition bars, Ramen, and Sujeonggwa were determined at 15, 10 and 6 kGy, respectively. All the Korean space food were certificated for use in space flight conditions of 30 days by the Russian Institute for Biomedical Problems.

  12. Characterization of Thymol blue Radiochromic dosimeters for high dose applications

    Directory of Open Access Journals (Sweden)

    Feras M. Aldweri

    2018-03-01

    Full Text Available Thymol blue (TB solutions and Thymol blue Polyvinyl Alcohol (TB-PVA films have been introduced as Radiochromic dosimeter for high dose applications. The dosimeters were irradiated with gamma ray (60Co source from 5 to 30 kGy for film, and from 0.150 kGy to 4 kGy for solution. The optical density of unirradiated and irradiated TB solution as well as TB-PVA film dosimeters were studied in terms of absorbance at 434 nm using UV/VIS spectrophotometer. The effects of scan temperature, light pre-gamma irradiation, dose rate, relative humidity and stability of the absorbance of solutions and films after irradiation were investigated. We found the dose sensitivity of TB solution and TB-PVA film dosimeters increases significantly with increases of the absorbed dose as well as with the increases of TB dye concentrations. The useful dose range of developed TB solutions and TB-PVA films dosimeters is in the range 0.125–1 kGy and of 5–20 kGy, respectively. Keywords: Dose sensitivity, Radio-chromic dosimeter, Thymol blue, Absorbance, Concentrations

  13. Shelf-stable food through high dose irradiation

    International Nuclear Information System (INIS)

    Placek, V.; Svobodova, V.; Bartonicek, B.; Rosmus, J.; Camra, M.

    2004-01-01

    Irradiation of food with high doses (radappertization) is a way, how to prepare shelf-stable ready-to-eat food. The radappertization process requires that the food be heated at first to an internal temperature of at least 75 deg. C to inactivate autolytic enzyme, which could cause the spoilage during storage without refrigeration. In order to prevent radiation induced changes in sensory properties (off flavors, odors, undesirable color change, etc.) the food was vacuum packed and irradiated in frozen state at -30 deg. C or less to a minimum dose of 35 kGy. Such products have characteristics of fresh food prepared for eating even if they are stored for long time under tropical conditions. The wholesomeness (safety for consumption) has been confirmed during 40 years of testing. Within the NRI Rez 10 kinds of shelf-stable meat products have been prepared. The meat was cooked, vacuum packed in SiO x -containing pouch, freezed in liquid nitrogen and irradiated with electron beam accelerator. The microbial, chemical, and organoleptic properties have been tested

  14. Ion exchange resins as high-dose radiation dosimeters

    International Nuclear Information System (INIS)

    Alian, A.; Dessouki, A.; El-Assay, N.B.

    1984-01-01

    This paper reports on the possibility of using various types of ion exchange resins as high-dose radiation dosimeters, by analysis of the decrease in exchange capacity with absorbed dose. The resins studied are Sojuzchim-export-Moscow Cation Exchanger KU-2 and Anion Exchanger AV-17 and Merck Cation Exchanger I, and Merck Anion Exchangers II and III. Over the dose range 1 to 100 kGy, the systems show linearity between log absorbed dose and decrease in resin ion exchange capacity. The slope of this response function differs for the different resins, depending on their ionic form and degree of cross-linking. The radiation sensitivity increases in the order KU-2; Exchanger I; AV-17; Exchanger II; Exchanger III. Merck resins with moisture content of 21% showed considerably higher radiation sensitivity than those with 2 to 3% moisture content. The mechanism of radiation-induced denaturing of the ion exchanger resins involves cleavage and decomposition of functional substituents, with crosslinking playing a stabilizing role, with water and its radiolytic products serving to inhibit radical recombination and interfering with the protection cage effect of crosslinking. (author)

  15. High dose rate brachytherapy for the palliation of malignant dysphagia

    International Nuclear Information System (INIS)

    Homs, Marjolein Y.V.; Eijkenboom, Wilhelmina M.H.; Coen, Veronique L.M.A.; Haringsma, Jelle; Blankenstein, Mark van; Kuipers, Ernst J.; Siersema, Peter D.

    2003-01-01

    Background and purpose: High dose rate (HDR) brachytherapy is a commonly used palliative treatment for esophageal carcinoma. We evaluated the outcome of HDR brachytherapy in patients with malignant dysphagia. Material and methods: A retrospective analysis over a 10-year period was performed of 149 patients treated with HDR brachytherapy, administered in one or two sessions, at a median dose of 15 Gy. Patients were evaluated for functional outcome, complications, recurrent dysphagia, and survival. Results: At 6 weeks after HDR brachytherapy, dysphagia scores had improved from a median of 3 to 2 (n=104; P<0.001), however, dysphagia had not improved in 51 (49%) patients. Procedure-related complications occurred in seven (5%) patients. Late complications, including fistula formation or bleeding, occurred in 11 (7%) patients. Twelve (8%) patients experienced minor retrosternal pain. Median survival of the patients was 160 days with a 1-year survival rate of 15%. Procedure-related mortality was 2%. At follow-up, 55 (37%) patients experienced recurrent dysphagia. In 34 (23%) patients a metal stent was placed to relieve persistent or recurrent dysphagia. Conclusion: HDR brachytherapy is a moderately effective treatment for the palliation of malignant dysphagia. The incidence of early major complications is low, however, persistent and recurrent dysphagia occur frequently, and require often additional treatment

  16. High dose tetrabromobisphenol A impairs hippocampal neurogenesis and memory retention.

    Science.gov (United States)

    Kim, Ah Hyun; Chun, Hye Jeong; Lee, Seulah; Kim, Hyung Sik; Lee, Jaewon

    2017-08-01

    Tetrabromobisphenol A (TBBPA) is a brominated flame retardant that is commonly used in commercial and household products, such as, computers, televisions, mobile phones, and electronic boards. TBBPA can accumulate in human body fluids, and it has been reported that TBBPA possesses endocrine disruptive activity. However, the neurotoxic effect of TBBPA on hippocampal neurogenesis has not yet been investigated. Accordingly, the present study was undertaken to evaluate the effect of TBBPA on adult hippocampal neurogenesis and cognitive function. Male C57BL/6 mice were orally administrated vehicle or TBBPA (20 mg/kg, 100 mg/kg, or 500 mg/kg daily) for two weeks. TBBPA was observed to significantly and dose-dependently reduce the survival of newly generated cells in the hippocampus but not to affect the proliferation of newly generated cells. Numbers of hippocampal BrdU and NeuN positive cells were dose-dependently reduced by TBBPA, indicating impaired neurogenesis in the hippocampus. Interestingly, glial activation without neuronal death was observed in hippocampi exposed to TBBPA. Furthermore, memory retention was found to be adversely affected by TBBPA exposure by a mechanism involving suppression of the BDNF-CREB signaling pathway. The study suggests high dose TBBPA disrupts hippocampal neurogenesis and induces associated memory deficits. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Dimethyl sulfoxyde diethyl fumarate solution for high dose dosimetry

    International Nuclear Information System (INIS)

    Al-Kassiri, H.; Kattan, M.; Daher, Y.

    2007-06-01

    Dosimetric characterization of diethyl fumarate DEF in dimethyl sulfoxyde DMSO solution has been studied spectrophotometrically for possible application at high dose radiation dosimetry in the range (0-225 kGy). The absorption spectra of irradiated solution showed broad absorption bands between (325-400 nm) with a shoulder at 332 nm. The absorption increases as the dose is increased. Absorbance at 332 nm were measured and plotted against absorbed dose. Linear relationship and good response were found between absorbed dose and absorbance of 20% DEF concentration in the range (0-225 kGy) at the wave length, and linearity up to 250 kGy of absorbance at 332 nm .Good dose rate independence was observed in the range (14-33 kGy/h). The effect of post irradiation storage in darkness and indirect daylight conditions were not found to influence the absorption up to 700 h after irradiation. The effect of irradiation temperature within the range (0 to 60 centigrade degree) on the dosimetry performance was discussed.(author)

  18. Radiation Parameters of High Dose Rate Iridium -192 Sources

    Science.gov (United States)

    Podgorsak, Matthew B.

    A lack of physical data for high dose rate (HDR) Ir-192 sources has necessitated the use of basic radiation parameters measured with low dose rate (LDR) Ir-192 seeds and ribbons in HDR dosimetry calculations. A rigorous examination of the radiation parameters of several HDR Ir-192 sources has shown that this extension of physical data from LDR to HDR Ir-192 may be inaccurate. Uncertainty in any of the basic radiation parameters used in dosimetry calculations compromises the accuracy of the calculated dose distribution and the subsequent dose delivery. Dose errors of up to 0.3%, 6%, and 2% can result from the use of currently accepted values for the half-life, exposure rate constant, and dose buildup effect, respectively. Since an accuracy of 5% in the delivered dose is essential to prevent severe complications or tumor regrowth, the use of basic physical constants with uncertainties approaching 6% is unacceptable. A systematic evaluation of the pertinent radiation parameters contributes to a reduction in the overall uncertainty in HDR Ir-192 dose delivery. Moreover, the results of the studies described in this thesis contribute significantly to the establishment of standardized numerical values to be used in HDR Ir-192 dosimetry calculations.

  19. High-dose processing and application to Korean space foods

    Science.gov (United States)

    Song, Beom-Seok; Park, Jin-Gyu; Park, Jae-Nam; Han, In-Jun; Choi, Jong-il; Kim, Jae-Hun; Byun, Myung-Woo; Kang, Sang-Wook; Choi, Gi-Hyuk; Lee, Ju-Woon

    2009-07-01

    Nutrition bar, Ramen (ready-to-cook noodle), and two Korean traditional foods ( Kimchi, fermented vegetable; Sujeonggwa, cinnamon beverage) have been developed as space foods using high-dose gamma irradiation. Addition of calcium lactate and vitamin C, a mild heating, deep-freezing, and gamma irradiation at 25 kGy were conducted to prepare Kimchi as a ready-to-eat space food. Sterilization of Space Kimchi (SK) was confirmed by a microbiological test. The hardness of the Space Kimchi was lower than the untreated Kimchi (CON), but higher than the irradiated only Kimchi. Sensory attributes of the SK were similar to CON, and maintained during preservation at 35 °C for 30 days. The optimal doses for eliminating the contaminated microbes and maintaining the qualities of the Nutrition bars, Ramen, and Sujeonggwa were determined at 15, 10 and 6 kGy, respectively. All the Korean space food were certificated for use in space flight conditions of 30 days by the Russian Institute for Biomedical Problems.

  20. Colon mucosal cells after high-dose fractional irradiation

    International Nuclear Information System (INIS)

    Zorc-Pleskovic, R.; Vraspir-Porenta, O.; Petrovic, D.; Zorc, M.; Pleskovic, L.

    2000-01-01

    The aim of this study was to investigate histological and stereological changes in cryptal enterocytes, mucosal lymphocytes and mast cells 10 days after irradiation. For experimental model, 24 Beagle dogs 1-2 years old were used. Twelve dogs were irradiated 20 days with 32 Gy over the whole pelvis and tail. Another 12 dogs represented a control group. For the detection of apoptosis, the TUNEL technique was used. Histological and stereological analyses were performed using a Wild sampling microscope M 1000. In the irradiated group, volume density (P < 0.01), numerical density (P < 0.05) and average volume of lymphocytes (P < 0.001) were significantly lower than in the nonirradiated group. Numerical areal density of mast cells in the irradiated group was also significantly lower (P < 0.05). Volume density (P < 0.001) and average volume of mast cells (P < 0.001) were significantly higher in the irradiated group. The results of our experiments show that irradiation causes injury and loss of lymphocytes and mast cells in the colon mucosa. Apoptosis was detected in enterocytes and lymphocytes in the irradiated group and in nonirradiated group in equal numbers (2.5 ± 0.3 vs. 2.3 ± 0.3; ns.), suggesting that 10 days after high-dose irradiation, the cell loss is not due to apoptosis. (author)

  1. Tungsten and carbon surface change under high dose plasma exposure

    International Nuclear Information System (INIS)

    Martynenko, Y.V.; Khripunov, B.I.; Petrov, V.B.

    2009-01-01

    Study of surface composition dynamics has been made on the LENTA linear plasma simulator. Experiments have been made on tungsten and carbon materials subjected to steady-state plasma exposure. The achieved ion doses on the surface were 10 21 ion cm -2 . WL 10 tungsten containing 1% of La2O3 oxide and titanium-doped graphite RG-T were studied. The following experimental conditions were varied in these experiments: energy of ions, surface temperature, working gas. Irradiations of tungsten WL 10 were executed in deuterium plasma at low ion energies (about 20 eV) and at 200 eV for temperatures below 340 K. Graphite RG-T was exposed at 1300 K. Elevated surface temperature (about 1050K) was also characteristic of experiments on tungsten sample under nitrogen plasma impact (simulated inter-ELMs condition). Surface microstructure modification has been observed and surface composition changes were found on the materials showing influence of high dose plasma irradiations on element redistribution in the near surface layers. (author)

  2. High dose progesterone effects the growth of early chick embryo

    International Nuclear Information System (INIS)

    Iqbal, I.; Qamar, K.

    2014-01-01

    Objective: To find out the effect of high dose progesterone on the development of early chick embryo. Study Design: Lab based randomized controlled trial. Place and Duration of study: This study was carried out in Army Medical College and Post Graduate Institute of Poultry Sciences, Rawalpindi from June 2010 - December 2010. Material and Methods: Forty five specific pathogen free, fertile, eggs of Fyoumi species of chick were selected at zero hour of incubation. They were incubated at 37.5oC and 75% relative humidity for 26 hrs until the embryos reached stage 8 of the development. Then on stage 8 the eggs were divided into three groups consisting of 15 eggs per group. The first group (GI) was incubated without any operation. The second (G2) and third groups (G3) were injected with two and twenty times more than physiologic does of progesterone respectively. After 48 hours of incvbation, all embryos were examined for their development under light microscopy. Results: All the embryos of G1 and G2 showed normal development according to their stage of development, while 4 out of 11 embryos of G3 were under developed and their survival rate was also less. Conclusion: Exogenous progesterone at levels twenty times above its physiologic range effects the development of chick embryos. Further studies are needed to explain the mechanisms of this effect. (author)

  3. Calibration of high-dose radiation facilities (Handbook)

    International Nuclear Information System (INIS)

    Gupta, B.L.; Bhat, R.M.

    1986-01-01

    In India at present several high intensity radiation sources are used. There are 135 teletheraphy machines and 65 high intensity cobalt-60 sources in the form of gamma chambers (2.5 Ci) and PANBIT (50 Ci). Several food irradiation facilities and a medical sterilization plant ISOMED are also in operation. The application of these high intensity sources involve a wide variation of dose from 10 Gy to 100 kGy. Accurate and reproducible radiation dosimetry is essential in the use of these sources. This handbook is especially compiled for calibration of high-dose radiation facilities. The first few chapters discuss such topics as interaction of radiation with matter, radiation chemistry, radiation processing, commonly used high intensity radiation sources and their special features, radiation units and dosimetry principles. In the chapters which follow, chemical dosimeters are discussed in detail. This discussion covers Fricke dosimeter, FBX dosimeter, ceric sulphate dosimeter, free radical dosimetry, coloured indicators for irrdiation verification. A final chapter is devoted to practical hints to be followed in calibration work. (author)

  4. High-dose processing and application to Korean space foods

    International Nuclear Information System (INIS)

    Song, Beom-Seok; Park, Jin-Gyu; Park, Jae-Nam; Han, In-Jun; Choi, Jong-il; Kim, Jae-Hun; Byun, Myung-Woo; Kang, Sang-Wook; Choi, Gi-Hyuk; Lee, Ju-Woon

    2009-01-01

    Nutrition bar, Ramen (ready-to-cook noodle), and two Korean traditional foods (Kimchi, fermented vegetable; Sujeonggwa, cinnamon beverage) have been developed as space foods using high-dose gamma irradiation. Addition of calcium lactate and vitamin C, a mild heating, deep-freezing, and gamma irradiation at 25 kGy were conducted to prepare Kimchi as a ready-to-eat space food. Sterilization of Space Kimchi (SK) was confirmed by a microbiological test. The hardness of the Space Kimchi was lower than the untreated Kimchi (CON), but higher than the irradiated only Kimchi. Sensory attributes of the SK were similar to CON, and maintained during preservation at 35 o C for 30 days. The optimal doses for eliminating the contaminated microbes and maintaining the qualities of the Nutrition bars, Ramen, and Sujeonggwa were determined at 15, 10 and 6 kGy, respectively. All the Korean space food were certificated for use in space flight conditions of 30 days by the Russian Institute for Biomedical Problems.

  5. Complications Associated With High-dose Corticosteroid Administration in Children With Spinal Cord Injury.

    Science.gov (United States)

    Cage, Jason M; Knox, Jeffrey B; Wimberly, Robert L; Shaha, Steve; Jo, ChanHee; Riccio, Anthony I

    2015-01-01

    Complications with high-dose steroid administration for spinal cord injury are documented in adult patients. Our purpose was to determine the incidence of early complications of this therapy in pediatric patients with spinal cord injuries. An IRB-approved retrospective review was performed for patients treated for spinal cord injury at a level 1 pediatric trauma center between 2003 and 2011. Demographic data, injury characteristics, and surgical interventions were documented. Complications were divided into 4 categories: infectious, gastrointestinal (GI), hyperglycemia/endocrine, and wound healing problems. Complication rates were compared using a Student's t test and Fischer's exact test. Thirty-four spinal cord injury patients were identified. Twenty-three patients (mean age 6.6 y) in the treatment group received high-dose steroid treatment and 11 patients (mean age 8.4 y) did not and comprised the control group. No statistical difference was detected between the 2 groups regarding age, mechanism of injury, rate of surgical intervention, level of injury, and injury severity. Hyperglycemia was the most common complication and was present in all patients in both the treatment and control groups. The overall infection rate was 64% in the control group compared with 26% in the treatment (Pspinal trauma in a pediatric population. Hyperglycemia was found in all spinal cord injury patients, regardless of steroid treatment. Paradoxically, infection rates were noted to be higher in the control group. GI and wound problems were not significantly different. Larger, multicenter prospective studies are needed to better understand the risks in pediatric SCI patients.

  6. Coating compositions comprising bismuth-alloyed zinc

    DEFF Research Database (Denmark)

    2008-01-01

    The present application discloses (i) a coating composition comprising a particulate zinc-based alloyed material, said material comprising 0.05-0.7% by weight of bismuth (Bi), the D50 of the particulate material being in the range of 2.5-30 µm; (ii) a coated structure comprising a metal structure...... having a first coating of the zinc-containing coating composition applied onto at least a part of the metal structure in a dry film thickness of 5-100 µm; and an outer coating applied onto said zinc-containing coating in a dry film thickness of 30-200 µm; (iii) a particulate zinc-based alloyed material......, wherein the material comprises 0.05-0.7%(w/w) of bismuth (Bi), and wherein the D50 of the particulate material is in the range of 2.5-30 µm; (iv) a composite powder consisting of at least 25%(w/w) of the particulate zinc-based alloyed material, the rest being a particulate material consisting of zinc...

  7. Biocatalytic material comprising multilayer enzyme coated fiber

    Science.gov (United States)

    Kim, Jungbae [Richland, WA; Kwak, Ja Hun [Richland, WA; Grate, Jay W [West Richland, WA

    2009-11-03

    The present invention relates generally to high stability, high activity biocatalytic materials and processes for using the same. The materials comprise enzyme aggregate coatings having high biocatalytic activity and stability useful in heterogeneous environment. These new materials provide a new biocatalytic immobilized enzyme system with applications in bioconversion, bioremediation, biosensors, and biofuel cells.

  8. Physics and quality assurance for high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Anderson, Lowell L.

    1995-01-01

    Purpose: To review the physical aspects of high dose rate (HDR) brachytherapy, including commissioning and quality assurance, source calibration and dose distribution measurements, and treatment planning methods. Following the introduction of afterloading in brachytherapy, development efforts to make it 'remote' culminated in 1964 with the near-simultaneous appearance of remote afterloaders in five major medical centers. Four of these machines were 'high dose rate', three employing 60Co and one (the GammaMed) using a single, cable-mounted 192Ir source. Stepping-motor source control was added to the GammaMed in 1974, making it the precursor of modern remote afterloaders, which are now suitable for interstitial as well as intracavitary brachytherapy by virtue of small source-diameter and indexer-accessed multiple channels. Because the 192Ir sources currently used in HDR remote afterloaders are supplied at a nominal air-kerma strength of 11.4 cGy cm2 s-1 (10 Ci), are not collimated in clinical use, and emit a significant fraction (15%) of photons at energies greater than 600 keV, shielding and facility design must be undertaken as carefully and thoroughly as for external beam installations. Licensing requirements of regulatory agencies must be met with respect both to maximum permissible dose limits and to the existence and functionality of safety devices (door interlocks, radiation monitors, etc.). Commissioning and quality assurance procedures that must be documented for HDR remote afterloading relate to (1) machine, applicator, guide-tube, and facility functionality checks, (2) source calibration, (3) emergency response readiness, (4) planning software evaluation, and (5) independent checks of clinical dose calculations. Source calibration checks must be performed locally, either by in-air measurement of air kerma strength or with a well ionization chamber calibrated (by an accredited standards laboratory) against an in-air measurement of air kerma strength for the

  9. Investigation of polymer composite for high dose dosimetry

    International Nuclear Information System (INIS)

    Pereira, E.L.M.; Batista, A.S.M.; Ribeiro, F.A.S.; Santos, A.P.; Faria, L.O.; Oliveira, A.H.

    2017-01-01

    Introduction: This paper presents the efficacy evaluation of PVDF and nanocomposites of the PVDF films for high gamma dosimetry. Our scope in this first part of our studies is the selection of the most promising film for future dosimetry trials, where the proportionality of response of the selected material will be investigated over a large range of doses and dose rates. Methods: Was prepared nanocomposites made by mixing Poly(vinylidene fluoride) (PVDF), zirconium oxide (ZrO 2 ) and multi-walled carbon nanotubes (MWCNTs) aiming to find dosimetric properties for applications in high dose dosimetry. The samples were irradiated with a Co-60 source at constant dose rate (16.7 kGy/h), with doses ranging from 100 to 2750 kGy. The UV-Vis and FTIR spectrophotometry have been used to monitor the appearing of C=C conjugated bonds and radio-oxidation of carbon (C=O). Results: FTIR spectrometry has that the absorbance intensities at 1715 cm -1 and 1730 cm -1 can be used for high dosimetry purposes for gamma doses ranging from 400 to 2750 kGy. In this range, it is possible to observe a linear relationship between Abs & Dose. Fading of signal was evaluated for one month and reproducibility in 2000 kGy dose. Conclusion: FTIR spectroscopic data revealed two optical absorption bands at 1715 cm -1 and 1730 cm -1 whose intensities are unambiguously related to gamma delivered dose ranging from 400 kGy to 2750 kGy. (author)

  10. Investigation of polymer composite for high dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, E.L.M.; Batista, A.S.M., E-mail: adriananuclear@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Ribeiro, F.A.S.; Santos, A.P.; Faria, L.O.; Oliveira, A.H. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Introduction: This paper presents the efficacy evaluation of PVDF and nanocomposites of the PVDF films for high gamma dosimetry. Our scope in this first part of our studies is the selection of the most promising film for future dosimetry trials, where the proportionality of response of the selected material will be investigated over a large range of doses and dose rates. Methods: Was prepared nanocomposites made by mixing Poly(vinylidene fluoride) (PVDF), zirconium oxide (ZrO{sub 2}) and multi-walled carbon nanotubes (MWCNTs) aiming to find dosimetric properties for applications in high dose dosimetry. The samples were irradiated with a Co-60 source at constant dose rate (16.7 kGy/h), with doses ranging from 100 to 2750 kGy. The UV-Vis and FTIR spectrophotometry have been used to monitor the appearing of C=C conjugated bonds and radio-oxidation of carbon (C=O). Results: FTIR spectrometry has that the absorbance intensities at 1715 cm{sup -1} and 1730 cm{sup -1} can be used for high dosimetry purposes for gamma doses ranging from 400 to 2750 kGy. In this range, it is possible to observe a linear relationship between Abs & Dose. Fading of signal was evaluated for one month and reproducibility in 2000 kGy dose. Conclusion: FTIR spectroscopic data revealed two optical absorption bands at 1715 cm{sup -1} and 1730 cm{sup -1} whose intensities are unambiguously related to gamma delivered dose ranging from 400 kGy to 2750 kGy. (author)

  11. Urethral stricture following high dose rate brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Sullivan, Lisa; Williams, Scott G.; Tai, Keen Hun; Foroudi, Farshad; Cleeve, L.; Duchesne, Gillian M.

    2009-01-01

    Purpose: To evaluate the incidence, timing, nature and outcome of urethral strictures following high dose rate brachytherapy (HDRB) for prostate carcinoma. Methods and materials: Data from 474 patients with clinically localised prostate cancer treated with HDRB were analysed. Ninety percent received HDRB as a boost to external beam radiotherapy (HDRBB) and the remainder as monotherapy (HDRBM). Urethral strictures were graded according to the Common Terminology Criteria for Adverse Events v3.0. Results: At a median follow-up of 41 months, 38 patients (8%) were diagnosed with a urethral stricture (6-year actuarial risk 12%). Stricture location was bulbo-membranous (BM) urethra in 92.1%. The overall actuarial rate of grade 2 or more BM urethral stricture was estimated at 10.8% (95% CI 7.0-14.9%), with a median time to diagnosis of 22 months (range 10-68 months). All strictures were initially managed with either dilatation (n = 15) or optical urethrotomy (n = 20). Second line therapy was required in 17 cases (49%), third line in three cases (9%) and 1 patient open urethroplasty (grade 3 toxicity). Predictive factors on multivariate analysis were prior trans-urethral resection of prostate (hazard ratio (HR) 2.81, 95% CI 1.15-6.85, p = 0.023); hypertension (HR 2.83, 95% CI 1.37-5.85, p = 0.005); and dose per fraction used in HDR (HR for 1 Gy increase per fraction 1.33, 95% CI 1.08-1.64, p = 0.008). Conclusions: BM urethral strictures are the most common late grade 2 or more urinary toxicity following HDR brachytherapy for prostate cancer. Most are manageable with minimally invasive procedures. Both clinical and dosimetric factors appear to influence the risk of stricture formation.

  12. Tolerance of the Brachial Plexus to High-Dose Reirradiation

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Allen M., E-mail: achen5@kumc.edu; Yoshizaki, Taeko; Velez, Maria A.; Mikaeilian, Argin G.; Hsu, Sophia; Cao, Minsong

    2017-05-01

    Purpose: To study the tolerance of the brachial plexus to high doses of radiation exceeding historically accepted limits by analyzing human subjects treated with reirradiation for recurrent tumors of the head and neck. Methods and Materials: Data from 43 patients who were confirmed to have received overlapping dose to the brachial plexus after review of radiation treatment plans from the initial and reirradiation courses were used to model the tolerance of this normal tissue structure. A standardized instrument for symptoms of neuropathy believed to be related to brachial plexus injury was utilized to screen for toxicity. Cumulative dose was calculated by fusing the initial dose distributions onto the reirradiation plan, thereby creating a composite plan via deformable image registration. The median elapsed time from the initial course of radiation therapy to reirradiation was 24 months (range, 3-144 months). Results: The dominant complaints among patients with symptoms were ipsilateral pain (54%), numbness/tingling (31%), and motor weakness and/or difficulty with manual dexterity (15%). The cumulative maximum dose (Dmax) received by the brachial plexus ranged from 60.5 Gy to 150.1 Gy (median, 95.0 Gy). The cumulative mean (Dmean) dose ranged from 20.2 Gy to 111.5 Gy (median, 63.8 Gy). The 1-year freedom from brachial plexus–related neuropathy was 67% and 86% for subjects with a cumulative Dmax greater than and less than 95.0 Gy, respectively (P=.05). The 1-year complication-free rate was 66% and 87%, for those reirradiated within and after 2 years from the initial course, respectively (P=.06). Conclusion: The development of brachial plexus–related symptoms was less than expected owing to repair kinetics and to the relatively short survival of the subject population. Time-dose factors were demonstrated to be predictive of complications.

  13. Reduced time for urinary alkalinization before high-dose methotrexate with preadmission oral bicarbonate.

    Science.gov (United States)

    Kintzel, Polly E; Campbell, Alan D; Yost, Kathleen J; Brinker, Brett T; Arradaza, Nicole V; Frobish, Daniel; Wehr, Alison M; O'Rourke, Timothy J

    2012-06-01

    Hydration and urinary alkalinization are essential for reducing renal dysfunction with high dose methotrexate (HDMTX). This report presents an analysis of institutional methods used to achieve adequate urinary alkalinization and output for patients receiving single agent HDMTX. Renal and metabolic parameters of tolerance were examined. Medical records of adult patients receiving HDMTX during the calendar years of 2008-2009 were retrospectively reviewed to determine the time to achieve urine pH > 7. Number of hospital days, bicarbonate dose, ordered hydration rate, urine output, and urine pH were assessed. A survival analysis model was run for time to urine pH > 7 using preadmission oral bicarbonate as a predictor variable and including a frailty term. Observational statistics were performed for other parameters. The analysis included 79 encounters for ten patients. Urine pH > 7 was achieved more rapidly in patients receiving preadmission oral bicarbonate (P = 0.012). The number of patients receiving HDMTX on the same day as admission was greater for those receiving preadmission oral bicarbonate (47%) in comparison to those who did not (2%), and they spent less time in the hospital. A standard regimen for hydration and urinary alkalinization based on this project is reported. The nature and frequency of adverse events were as expected for this treatment. At our institution, the time to achieve urinary alkalinization was reduced for patients receiving preadmission oral bicarbonate which facilitated chemotherapy infusion on the same day as admission and decreased the number of calendar days that patients stayed in the hospital.

  14. High-Dose Vitamin D3 during Tuberculosis Treatment in Mongolia. A Randomized Controlled Trial.

    Science.gov (United States)

    Ganmaa, Davaasambuu; Munkhzul, Baatar; Fawzi, Wafaie; Spiegelman, Donna; Willett, Walter C; Bayasgalan, Purev; Baasansuren, Erkhembayar; Buyankhishig, Burneebaatar; Oyun-Erdene, Sereeter; Jolliffe, David A; Xenakis, Theodoros; Bromage, Sabri; Bloom, Barry R; Martineau, Adrian R

    2017-09-01

    Existing trials of adjunctive vitamin D in the treatment of pulmonary tuberculosis (PTB) are variously limited by small sample sizes, inadequate dosing regimens, and high baseline vitamin D status among participants. Comprehensive analyses of the effects of genetic variation in the vitamin D pathway on response to vitamin D supplementation are lacking. To determine the effect of high-dose vitamin D 3 on response to antimicrobial therapy for PTB and to evaluate the influence of single-nucleotide polymorphisms (SNPs) in vitamin D pathway genes on response to adjunctive vitamin D 3 . We conducted a clinical trial in 390 adults with PTB in Ulaanbaatar, Mongolia, who were randomized to receive four biweekly doses of 3.5 mg (140,000 IU) vitamin D 3 (n = 190) or placebo (n = 200) during intensive-phase antituberculosis treatment. The intervention elevated 8-week serum 25-hydroxyvitamin D concentrations (154.5 nmol/L vs. 15.2 nmol/L in active vs. placebo arms, respectively; 95% confidence interval for difference, 125.9-154.7 nmol/L; P vitamin D 3 accelerated sputum culture conversion in patients with one or more minor alleles for SNPs in genes encoding the vitamin D receptor (rs4334089, rs11568820) and 25-hydroxyvitamin D 1α-hydroxylase (CYP27B1: rs4646536) (adjusted hazard ratio ≥ 1.47; P for interaction ≤ 0.02). Vitamin D 3 did not influence time to sputum culture conversion in the study population overall. Effects of the intervention were modified by SNPs in VDR and CYP27B1. Clinical trial registered with www.clinicaltrials.gov (NCT01657656).

  15. Oral High-Dose Multivitamins and Minerals or Post Myocardial Infarction Patients in TACT

    Science.gov (United States)

    Lamas, Gervasio A.; Boineau, Robin; Goertz, Christine; Mark, Daniel B.; Rosenberg, Yves; Stylianou, Mario; Rozema, Theodore; Nahin, Richard L.; Lindblad, Lauren; Lewis, Eldrin F.; Drisko, Jeanne; Lee, Kerry L.

    2014-01-01

    Background Oral multivitamins and minerals are often used in conjunction with ethylenediamine tetra acetic acid infusions to treat atherosclerotic disease. Whether high-dose multivitamins are effective as secondary prevention of atherosclerotic disease, however, has not been established. Objective The vitamin component of the Trial to Assess Chelation Therapy assessed whether oral multivitamins reduced cardiovascular events, and were safe. Design The Trial to Assess Chelation Therapy was designed as a double-blind placebo-controlled 2×2 factorial multicenter randomized trial. Setting 134 US and Canadian academic and clinical sites participated. Patients 1708 patients, age ≥50 years, ≥6 weeks post myocardial infarction, with creatinine level ≤ 176.8 µmol/L (2.0 mg/dL). (ClinicalTrials.gov: NCT00044213). Intervention Patients were randomly assigned to an oral 28-component high-dose multivitamin and multimineral mixture or placebo. Measurements Study results were analyzed per randomized group. The primary endpoint was time to total mortality, recurrent myocardial infarction, stroke, coronary revascularization, or hospitalization for angina. Limited secondary endpoints and subgroup analyses were also pre-specified. Results The median age was 65 years, 18% female. The qualifying myocardial infarction had occurred 4.6 (1.6, 9.2) years prior to enrollment. The median duration of follow-up was 55 months (IQR 26, 60) overall. The median number of months during which patients took their vitamins was 31 (13, 59) in the active treatment group, and 35 (13, 60) in the placebo group (p=0.65). There were 645 (76%) vitamin patients and 646 (76%) placebo patients who completed at least 1 year of oral therapy (p=0.98); and 400 (46.9%) vitamin patients and 426 (49.8%) placebo patients who completed at least 3 years of oral therapy (p=0.23). There were 783 (46%) of patients who discontinued their vitamin regimen (390 (46%) in placebo, 394 (46%) in active; p=0.67), and 17% of

  16. Downhole transmission system comprising a coaxial capacitor

    Science.gov (United States)

    Hall, David R [Provo, UT; Pixton, David S [Lehi, UT; Johnson, Monte L [Orem, UT; Bartholomew, David B [Springville, UT; Hall, Jr., H. Tracy; Rawle, Michael [Springville, UT

    2011-05-24

    A transmission system in a downhole component comprises a plurality of data transmission elements. A coaxial cable having an inner conductor and an outer conductor is disposed within a passage in the downhole component such that at least one capacitor is disposed in the passage and having a first terminal coupled to the inner conductor and a second terminal coupled to the outer conductor. Preferably the transmission element comprises an electrically conducting coil. Preferably, within the passage a connector is adapted to electrically connect the inner conductor of the coaxial cable and the lead wire. The coaxial capacitor may be disposed between and in electrically communication with the connector and the passage. In another embodiment a connector is adapted to electrical connect a first and a second portion of the inner conductor of the coaxial cable and a coaxial capacitor is in electrical communication with the connector and the passage.

  17. Nanophosphor composite scintillators comprising a polymer matrix

    Science.gov (United States)

    Muenchausen, Ross Edward; Mckigney, Edward Allen; Gilbertson, Robert David

    2010-11-16

    An improved nanophosphor composite comprises surface modified nanophosphor particles in a solid matrix. The nanophosphor particle surface is modified with an organic ligand, or by covalently bonding a polymeric or polymeric precursor material. The surface modified nanophosphor particle is essentially charge neutral, thereby preventing agglomeration of the nanophosphor particles during formation of the composite material. The improved nanophosphor composite may be used in any conventional scintillator application, including in a radiation detector.

  18. High-dose melphalan and autologous stem cell transplantation for AL amyloidosis: recent trends in treatment-related mortality and 1-year survival at a single institution

    Science.gov (United States)

    Seldin, D. C.; Andrea, N.; Berenbaum, I.; Berk, J. L.; Connors, L.; Dember, L. M.; Doros, G.; Fennessey, S.; Finn, K.; Girnius, S.; Lerner, A.; Libbey, C.; Meier-Ewert, H. K.; O’Connell, R.; O’Hara, C.; Quillen, K.; Ruberg, F. L.; Sam, F.; Segal, A.; Shelton, A.; Skinner, M.; Sloan, J. M.; Wiesman, J. F.; Sanchorawala, V.

    2017-01-01

    Treatment with high-dose melphalan chemotherapy supported by hematopoietic rescue with autologous stem cells produces high rates of hematologic responses and improvement in survival and organ function for patients with AL amyloidosis. Ongoing clinical trials explore pre-transplant induction regimens, post-transplant consolidation or maintenance approaches, and compare transplant to non-transplant regimens. To put these studies into context, we reviewed our recent experience with transplant for AL amyloidosis in the Amyloid Treatment and Research Program at Boston Medical Center and Boston University School of Medicine. Over the past 10 years, there was a steady reduction in rates of treatment-related mortality and improvement in 1-year survival, now approximately 5% and 90%, respectively, based upon an intention-to-treat analysis. Median overall survival of patients treated with this approach at our center exceeds 7.5 years. PMID:21838459

  19. HIGH-DOSE RATE BRACHYTHERAPY IN CARCINOMA CERVIX STAGE IIIB

    Directory of Open Access Journals (Sweden)

    Sathya Maruthavanan

    2016-07-01

    Full Text Available INTRODUCTION Radiotherapy is the standard treatment in locally advanced (IIB-IVA and early inoperable cases. The current standard of practice with curable intent is concurrent chemoradiation in which intracavitary brachytherapy is an integral component of radiotherapy. This study aims at assessing the efficacy of HDR ICBT (High-dose rate intracavitary brachytherapy in terms local response, normal tissue reactions, and feasibility. METHODS AND MATERIALS A total of 20 patients of stage IIIB cancer of the uterine cervix were enrolled in the study and were planned to receive concurrent chemotherapy weekly along with EBRT (external beam radiotherapy to a dose of 50 Gy/25 Fr. Suitability for ICBT was assessed at 40 Gy/20 Fr. 6/20 patients were suitable at 40 Gy and received HDR ICBT with a dose of 5.5 Gy to point A in 4 sessions (5.5 Gy/4 Fr. The remaining 14/20 patients completed 50 Gy and received HDR ICBT with a dose of 6 Gy to point A in 3 sessions (6 Gy/3 Fr. RESULTS A total of 66 intracavitary applications were done and only one application required dose modification due to high bladder dose, the pelvic control rate was 85% (17/20. 10% (2/20 had stable disease and 5% (1/20 had progressive disease at one year of follow up. When toxicity was considered only 15% developed grade I and grade II rectal complications. Patient compliance and acceptability was 100%. Patients were very comfortable with the short treatment time as compared with patients on LDR ICBT (low-dose rate intracavitary brachytherapy treatment interviewed during the same period. CONCLUSION This study proves that HDR brachytherapy is efficacious and feasible in carcinoma of cervix stage IIIB. It also proves that good dose distribution can be achieved with HDR intracavitary facility by the use of dose optimization. The short treatment time in HDR ICBT makes it possible to maintain this optimised dose distribution throughout the treatment providing a gain in the therapeutic ratio and

  20. Terbinafine in combination with other antifungal agents for treatment of resistant or refractory mycoses: investigating optimal dosing regimens using a physiologically based pharmacokinetic model.

    Science.gov (United States)

    Dolton, Michael J; Perera, Vidya; Pont, Lisa G; McLachlan, Andrew J

    2014-01-01

    Terbinafine is increasingly used in combination with other antifungal agents to treat resistant or refractory mycoses due to synergistic in vitro antifungal activity; high doses are commonly used, but limited data are available on systemic exposure, and no assessment of pharmacodynamic target attainment has been made. Using a physiologically based pharmacokinetic (PBPK) model for terbinafine, this study aimed to predict total and unbound terbinafine concentrations in plasma with a range of high-dose regimens and also calculate predicted pharmacodynamic parameters for terbinafine. Predicted terbinafine concentrations accumulated significantly during the first 28 days of treatment; the area under the concentration-time curve (AUC)/MIC ratios and AUC for the free, unbound fraction (fAUC)/MIC ratios increased by 54 to 62% on day 7 of treatment and by 80 to 92% on day 28 compared to day 1, depending on the dose regimen. Of the high-dose regimens investigated, 500 mg of terbinafine taken every 12 h provided the highest systemic exposure; on day 7 of treatment, the predicted AUC, maximum concentration (Cmax), and minimum concentration (Cmin) were approximately 4-fold, 1.9-fold, and 4.4-fold higher than with a standard-dose regimen of 250 mg once daily. Close agreement was seen between the concentrations predicted by the PBPK model and the observed concentrations, indicating good predictive performance. This study provides the first report of predicted terbinafine exposure in plasma with a range of high-dose regimens.

  1. Prophylactic CNS therapy in childhood leukemia. Randomized controlled study of high-dose intravenous methotrexate and cranial irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Takashi; Hiyoshi, Yasuhiko [Kurume Univ., Fukuoka (Japan). School of Medicine; Fujimoto, Takeo

    1982-12-01

    This study was designed to evaluate the efficacy of CNS-prophylaxis with high-dose methotrexate (MTX). Seventy children with previously untreated acute lymphoblastic leukemia (ALL) entered to this study between July 1978 and December 1980. According to initial white blood count (WBC), they were stratified to induce remission with; vincristine and prednine in low initial WBC ( lt 25,000/mm/sup 3/) group and these two agents plus adriamycin in high initial WBC ( gt 25,000/mm/sup 3/) group. After inducing remission, 62 children who achieved CR, received different CNS-prophlaxis; using a regimen of three doses of weekly high-dose MTX (1,000 mg/m/sup 2/) 6-hour infusion, which was repeated every 12 weeks-Group A (n = 14); high-dose MTX followed by 2400 rad cranial irradiation plus three doses of i.t. MT X-Group B (n = 15), 2400 rad cranial irradiation plus three doses of i.t. MTX-Group C (n = 16), and in 17 patients with high initial WBC, same as in Group A-Group D (n = 17). During an intravenous 6-h infusion of MTX at a dose of 1,000 mg/m/sup 2/, the CSF concentration of MTX rose to 2.3 +- 2.4 x 10/sup -6/M after initiation of infusion and remained in 10/sup -7/ M level for 48 hours. CNS-leukemia terminated complete remission in one of 14 children in Group A, two of 15 in Group B, two of 16 in Group C and two of 17 in Group D. The cumulative incidence of CNS-leukemia at 20 months calculated by the technique of Kaplan and Meier was 0% in Group A, 18.1% in Group B, 7.1% in Group C and 50.8% in Group D. There was no statistical difference among Groups A, B and C. These data suggested that CNS-prophylaxis with high-dose intravenous MTX was effective as well as 2400 rad cranial irradiation plus three doses of i.t. MTX in childhood ALL with low initial WBC.

  2. Fibrous composites comprising carbon nanotubes and silica

    Science.gov (United States)

    Peng, Huisheng [Shanghai, CN; Zhu, Yuntian Theodore [Cary, NC; Peterson, Dean E [Los Alamos, NM; Jia, Quanxi [Los Alamos, NM

    2011-10-11

    Fibrous composite comprising a plurality of carbon nanotubes; and a silica-containing moiety having one of the structures: (SiO).sub.3Si--(CH.sub.2).sub.n--NR.sub.1R.sub.2) or (SiO).sub.3Si--(CH.sub.2).sub.n--NCO; where n is from 1 to 6, and R.sub.1 and R.sub.2 are each independently H, CH.sub.3, or C.sub.2H.sub.5.

  3. Method of forming a nanocluster comprising dielectric layer and device comprising such a layer

    NARCIS (Netherlands)

    2009-01-01

    A method of forming a dielectric layer (330) on a further layer (114, 320) of a semiconductor device (300) is disclosed. The method comprises depositing a dielectric precursor compound and a further precursor compound over the further layer (114, 320), the dielectric precursor compound comprising a

  4. Clomiphene citrate versus high doses of gonadotropins for in vitro fertilisation in women with compromised ovarian reserve: a randomised controlled non-inferiority trial

    Directory of Open Access Journals (Sweden)

    Ragni Guido

    2012-12-01

    Full Text Available Abstract Background The aim of the present randomised controlled non-inferiority trial is to test whether in women with compromised ovarian reserve requiring in vitro fertilisation, a protocol of ovarian stimulation using exclusively clomiphene citrate performs similarly to a regimen with high doses of gonadotropins. Methods Women with day 3 serum FSH > 12 IU/ml on at least two occasions or previous poor response to hyper-stimulation were recruited at four Italian infertility units. Selected women were allocated to clomiphene citrate 150 mg/day from day 3 to day 7 of the cycle (n=145 or to a short protocol with GnRH agonist 0.1 mg and recombinant FSH 450 IU daily (n=146. They were randomised by means of a computer-generated list into two groups. The study was not blinded. The main outcome of the study was the delivery rate per started cycle. Results The study was interrupted after the scheduled two years of recruitment before reaching the sample size. 148 women were allocated to clomiphene citrate and 156 to the short protocol with high doses of gonadotropins; 124 and 125 participants were analysed in the groups, respectively. Women allocated to high doses of gonadotropins retrieved more oocytes and had a higher probability to perform embryo-transfer. However, the chances of success were similar. The delivery rate per started cycle in women receiving clomiphene citrate and high-dose gonadotropins was 3% (n=5 and 5% (n=7, respectively (p=0.77. The mean estimated cost per delivery in the two groups was 81,294 and 113,107 Euros, respectively. No side-effects or adverse events were observed. Conclusions In women with compromised ovarian reserve selected for in vitro fertilisation, ovarian stimulation with clomiphene citrate or high-dose gonadotropins led to similar chances of pregnancy but the former is less expensive. Trial registration Trial registered on http://www.clinicaltrials.gov (NCT01389713

  5. High dose rate 192Ir calibration: Indonesia experiences

    International Nuclear Information System (INIS)

    Nasukha; Tjiptanto, D.; Darmasyah, R.; Kurniawan, B.

    2002-01-01

    Indonesia with a population of more than 200 Million people which spread on about 5000 islands, up to now only has 23 radiotherapy centers and some not active anymore. As mention by Parkin et al that Cervix/Utery and breast cancer are the most estimated numbers of new cases of cancers in women for developing countries, stomach and lung cancers in men. Indonesia as a developing country is likely similar to other developing countries on numbers of new cases of cancers in women. But quite different in men, in Indonesia the most common cancers are nasopharynx and thyroid cancers. The use of lr-192 sources in high dose-rate (HDR) remotely afterloaded brachytherapy treatments have greatly increased in recent years and variety of such sources are commercially available. Nine radiotherapy centers in Indonesia installed Nucletron microSelectron HDR remote afterloader. Based on the data of CiptoMangunkusurno Hospital, Jakarta that the most common cancers are the cervix, breast, nasopharynx and thyroid cancers which of percentage are about 31%, 25 %, 13%, and 6 % respectively. It means that the use of HDR 192 Ir brachytherapy has to be an effective tool in the treatments. Two methods have been studied and applied to calibrate HDR 192 Ir brachytherapy in Indonesia, especially for Nucletron microSelectron HDR 192 lr remote afterloader brachytherapy. Calibration of HDR 192 Ir brachytherapy source has been done by Cavity lonization Chamber and with Well Type lonization Chamber. First, 0.6 cc of NE Farmer type dosimeter that was calibrated to 60 Co and 250 kV of x-rays in air kerma was used in this experiment. Position of measurement (detector and source) at the center of the room and about 1 meter from the floor. Eight variation of distances from 10 cm to 40 cms have been carried out measurement as recommended by IAEA-TECDOC-1079. Correction have been given for scatters, non-uniformity, and attenuation. To solve the problem of scatter correction factor was used Matlab programming

  6. High-dose-rate brachytherapy in uterine cervical carcinoma

    International Nuclear Information System (INIS)

    Patel, Firuza D.; Rai, Bhavana; Mallick, Indranil; Sharma, Suresh C.

    2005-01-01

    Purpose: High-dose-rate (HDR) brachytherapy is in wide use for curative treatment of cervical cancer. The American Brachytherapy Society has recommended that the individual fraction size be <7.5 Gy and the range of fractions should be four to eight; however, many fractionation schedules, varying from institution to institution, are in use. We use 9 Gy/fraction of HDR in two to five fractions in patients with carcinoma of the uterine cervix. We found that our results and toxicity were comparable to those reported in the literature and hereby present our experience with this fractionation schedule. Methods and Materials: A total of 121 patients with Stage I-III carcinoma of the uterine cervix were treated with HDR brachytherapy between 1996 and 2000. The total number of patients analyzed was 113. The median patient age was 53 years, and the histopathologic type was squamous cell carcinoma in 93% of patients. The patients were subdivided into Groups 1 and 2. In Group 1, 18 patients with Stage Ib-IIb disease, tumor size <4 cm, and preserved cervical anatomy underwent simultaneous external beam radiotherapy to the pelvis to a dose of 40 Gy in 20 fractions within 4 weeks with central shielding and HDR brachytherapy of 9 Gy/fraction, given weekly, and interdigitated with external beam radiotherapy. The 95 patients in Group 2, who had Stage IIb-IIIb disease underwent external beam radiotherapy to the pelvis to a dose of 46 Gy in 23 fractions within 4.5 weeks followed by two sessions of HDR intracavitary brachytherapy of 9 Gy each given 1 week apart. The follow-up range was 3-7 years (median, 36.4 months). Late toxicity was graded according to the Radiation Therapy Oncology Group criteria. Results: The 5-year actuarial local control and disease-free survival rate was 74.5% and 62.0%, respectively. The actuarial local control rate at 5 years was 100% for Stage I, 80% for Stage II, and 67.2% for Stage III patients. The 5-year actuarial disease-free survival rate was 88.8% for

  7. Electromagnetic radiation absorbers and modulators comprising polyaniline

    Science.gov (United States)

    Epstein, Arthur J.; Ginder, John M.; Roe, Mitchell G.; Hajiseyedjavadi, Hamid

    1992-01-01

    A composition for absorbing electromagnetic radiation, wherein said electromagnetic radiation possesses a wavelength generally in the range of from about 1000 Angstroms to about 50 meters, wherein said composition comprises a polyaniline composition of the formula ##STR1## where y can be equal to or greater than zero, and R.sup.1 and R.sup.2 are independently selected from the group containing of H, --OCH.sub.3, --CH.sub.3, --F, --Cl, --Br, --I, NR.sup.3 .sub.2, --NHCOR.sup.3, --OH, --O.sup.-, SR.sup.3, --OCOR.sup.3, --NO.sub.2, --COOH, --COOR.sup.3, --COR.sup.3, --CHO, and --CN, where R.sup.3 is a C.sub.1 to C.sub.8 alkyl, aryl or aralkyl group.

  8. The Role of High Dose Interleukin-2 in the Era of Targeted Therapy.

    Science.gov (United States)

    Gills, Jessie; Parker, William P; Pate, Scott; Niu, Sida; Van Veldhuizen, Peter; Mirza, Moben; Holzbeierlein, Jeffery M; Lee, Eugene K

    2017-09-01

    We assessed survival outcomes following high dose interleukin-2 in a contemporary cohort of patients during the era of targeted agents. We retrospectively reviewed the records of patients with metastatic renal cell carcinoma treated with high dose interleukin-2 between July 2007 and September 2014. Clinicopathological data were abstracted and patient response to therapy was based on RECIST (Response Evaluation Criteria In Solid Tumors), version 1.1 criteria. The Kaplan-Meier method was used to estimate progression-free and overall survival in the entire cohort, the response to high dose interleukin-2 in regard to previous targeted agent therapy and the response to the targeted agent in relation to the response to high dose interleukin-2. We identified 92 patients, of whom 87 had documentation of a response to high dose interleukin-2. Median overall survival was 34.4 months from the initiation of high dose interleukin-2 therapy in the entire cohort. Patients who received targeted therapy before high dose interleukin-2 had overall survival (median 34.4 and 30.0 months, p = 0.88) and progression-free survival (median 1.5 and 1.7 months, p = 0.8) similar to those in patients who received no prior therapy, respectively. Additionally, patients with a complete or partial response to high dose interleukin-2 had similar outcomes for subsequent targeted agents compared to patients whose best response was stable or progressive disease (median overall survival 30.1 vs 25.4 months, p = 0.4). Our data demonstrate that patient responses to high dose interleukin-2 and to targeted agents before and after receiving high dose interleukin-2 are independent. As such, carefully selected patients should be offered high dose interleukin-2 for the possibility of a complete and durable response without the fear of limiting the treatment benefit of targeted agents. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  9. Risks Associated with High-Dose Lactobacillus rhamnosus in an Escherichia coli Model of Piglet Diarrhoea

    DEFF Research Database (Denmark)

    Li, Xiao-Qiong; Zhu, Yao-Hong; Zhang, Hong-Fu

    2012-01-01

    might be more effective than a high dose at ameliorating diarrhoea. There is a risk that high-dose L. rhamnosus pretreatment may negate the preventative effects, thus decreasing the prophylactic benefits against potential enteric pathogens. Our data suggest a safe threshold for preventative use...

  10. Split high-dose oral levothyroxine treatment as a successful therapy option in myxedema coma.

    Science.gov (United States)

    Charoensri, Suranut; Sriphrapradang, Chutintorn; Nimitphong, Hataikarn

    2017-10-01

    High-dose intravenous thyroxine (T4) is the preferable treatment for myxedema coma. We describe the clinical course of a 69-year-old man who presented with myxedema coma and received oral levothyroxine (LT4) therapy (1 mg) in a split dose. This suggests split high-dose oral LT4 as a therapeutic option in myxedema coma.

  11. Modeling superhydrophobic surfaces comprised of random roughness

    Science.gov (United States)

    Samaha, M. A.; Tafreshi, H. Vahedi; Gad-El-Hak, M.

    2011-11-01

    We model the performance of superhydrophobic surfaces comprised of randomly distributed roughness that resembles natural surfaces, or those produced via random deposition of hydrophobic particles. Such a fabrication method is far less expensive than ordered-microstructured fabrication. The present numerical simulations are aimed at improving our understanding of the drag reduction effect and the stability of the air-water interface in terms of the microstructure parameters. For comparison and validation, we have also simulated the flow over superhydrophobic surfaces made up of aligned or staggered microposts for channel flows as well as streamwise or spanwise ridge configurations for pipe flows. The present results are compared with other theoretical and experimental studies. The numerical simulations indicate that the random distribution of surface roughness has a favorable effect on drag reduction, as long as the gas fraction is kept the same. The stability of the meniscus, however, is strongly influenced by the average spacing between the roughness peaks, which needs to be carefully examined before a surface can be recommended for fabrication. Financial support from DARPA, contract number W91CRB-10-1-0003, is acknowledged.

  12. High-doses of proton pump inhibitors in refractory gastro-intestinal cancer: A case series and the state of art.

    Science.gov (United States)

    Falcone, Rosa; Roberto, Michela; D'Antonio, Chiara; Romiti, Adriana; Milano, Annalisa; Onesti, Concetta Elisa; Marchetti, Paolo; Fais, Stefano

    2016-12-01

    In recent years, proton pump inhibitors (PPIs) have been investigated at high-dose to modulate tumour microenvironment acidification thus restoring chemotherapeutic sensitivity. Moreover, several clinical data supports the role of cytotoxic drugs at low-dose continuously delivered as anticancer therapy. Clinical records of three patients affected with gastrointestinal cancer refractory to standard treatments, who had received a combination of high-dose rabeprazole and metronomic chemotherapy were reviewed. The first case, a 78-year-old man was treated for lung metastasis from colon adenocarcinoma. The second case, a 73-year-old man was treated for metastatic rectal cancer to the liver. The third one, a 68-year-old man, underwent the combination regimen for colon cancer with lung, liver and peritoneal metastases. Despite the failure of previous standard chemotherapy for metastatic disease, good clinical outcome was shown in these patients treated with an unconventional association of high-dose PPIs and metronomic chemotherapy. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  13. Desensitization Using Bortezomib and High-dose Immunoglobulin Increases Rate of Deceased Donor Kidney Transplantation.

    Science.gov (United States)

    Jeong, Jong Cheol; Jambaldorj, Enkthuya; Kwon, Hyuk Yong; Kim, Myung-Gyu; Im, Hye Jin; Jeon, Hee Jung; In, Ji Won; Han, Miyeun; Koo, Tai Yeon; Chung, Junho; Song, Eun Young; Ahn, Curie; Yang, Jaeseok

    2016-02-01

    Combination therapy of intravenous immunoglobulin (IVIG) and rituximab showed a good transplant rate in highly sensitized wait-listed patients for deceased donor kidney transplantation (DDKT), but carried the risk of antibody-mediated rejection. The authors investigated the impact of a new combination therapy of bortezomib, IVIG, and rituximab on transplantation rate.This study was a prospective, open-labeled clinical trial. The desensitization regimen consisted of 2 doses of IVIG (2  g/kg), a single dose of rituximab (375  mg/m), and 4 doses of bortezomib (1.3  mg/m). The transplant rate was analyzed. Anti-Human leukocyte antigen (HLA) DRB antibodies were determined by a Luminex solid-phase bead assay at baseline and after 2, 3, and 6 months in the desensitized patients.There were 19 highly sensitized patients who received desensitization and 17 patients in the control group. Baseline values of class I and II panel reactive antibody (%, peak mean fluorescence intensity) were 83  ±  16.0 (14952  ±  5820) and 63  ±  36.0 (10321  ±  7421), respectively. Deceased donor kidney transplantation was successfully performed in 8 patients (42.1%) in the desensitization group versus 4 (23.5%) in the control group. Multivariate time-varying covariate Cox regression analysis showed that desensitization increased the probability of DDKT (hazard ratio, 46.895; 95% confidence interval, 3.468-634.132; P = 0.004). Desensitization decreased mean fluorescence intensity values of class I panel reactive antibody by 15.5% (20.8%) at 2 months. In addition, a liberal mismatch strategy in post hoc analysis increased the benefit of desensitization in donor-specific antibody reduction. Desensitization was well tolerated, and acute rejection occurred only in the control group.In conclusion, a desensitization protocol using bortezomib, high-dose IVIG, and rituximab increased the DDKT rate in highly sensitized, wait-listed patients.

  14. Constitutive gene expression profile segregates toxicity in locally advanced breast cancer patients treated with high-dose hyperfractionated radical radiotherapy

    International Nuclear Information System (INIS)

    Henríquez Hernández, Luis Alberto; Lara, Pedro Carlos; Pinar, Beatriz; Bordón, Elisa; Gallego, Carlos Rodríguez; Bilbao, Cristina; Pérez, Leandro Fernández; Morales, Amílcar Flores

    2009-01-01

    Breast cancer patients show a wide variation in normal tissue reactions after radiotherapy. The individual sensitivity to x-rays limits the efficiency of the therapy. Prediction of individual sensitivity to radiotherapy could help to select the radiation protocol and to improve treatment results. The aim of this study was to assess the relationship between gene expression profiles of ex vivo un-irradiated and irradiated lymphocytes and the development of toxicity due to high-dose hyperfractionated radiotherapy in patients with locally advanced breast cancer. Raw data from microarray experiments were uploaded to the Gene Expression Omnibus Database http://www.ncbi.nlm.nih.gov/geo/ (GEO accession GSE15341). We obtained a small group of 81 genes significantly regulated by radiotherapy, lumped in 50 relevant pathways. Using ANOVA and t-test statistical tools we found 20 and 26 constitutive genes (0 Gy) that segregate patients with and without acute and late toxicity, respectively. Non-supervised hierarchical clustering was used for the visualization of results. Six and 9 pathways were significantly regulated respectively. Concerning to irradiated lymphocytes (2 Gy), we founded 29 genes that separate patients with acute toxicity and without it. Those genes were gathered in 4 significant pathways. We could not identify a set of genes that segregates patients with and without late toxicity. In conclusion, we have found an association between the constitutive gene expression profile of peripheral blood lymphocytes and the development of acute and late toxicity in consecutive, unselected patients. These observations suggest the possibility of predicting normal tissue response to irradiation in high-dose non-conventional radiation therapy regimens. Prospective studies with higher number of patients are needed to validate these preliminary results

  15. A Phase I Trial of High-Dose Lenalidomide and Melphalan as Conditioning for Autologous Stem Cell Transplantation in Relapsed or Refractory Multiple Myeloma.

    Science.gov (United States)

    Mark, Tomer M; Guarneri, Danielle; Forsberg, Peter; Rossi, Adriana; Pearse, Roger; Perry, Arthur; Pekle, Karen; Tegnestam, Linda; Greenberg, June; Shore, Tsiporah; Gergis, Usama; Mayer, Sebastian; Van Besien, Koen; Ely, Scott; Jayabalan, David; Sherbenou, Daniel; Coleman, Morton; Niesvizky, Ruben

    2017-06-01

    Autologous stem cell transplantation (ASCT) conditioned with high-dose chemotherapy has long been established as the standard of care for eligible patients with newly diagnosed multiple myeloma. Despite recent therapeutic advances, high-dose melphalan (HDM) remains the chemotherapy regimen of choice in this setting. Lenalidomide (LEN) in combination with low-dose dexamethasone is recognized as a standard of care for patients with relapsed or refractory multiple myeloma (RRMM), and there is growing support for the administration of LEN as maintenance therapy post-ASCT. In view of the above, the present phase I clinical trial was designed to evaluate the safety and tolerability of high-dose LEN (HDLEN) in patients with RRMM, and to determine the maximum tolerated dose of HDLEN when added to HDM before ASCT. Despite administering HDLEN at doses of up to 350 mg/day, the maximum tolerated dose could not be determined, owing to an insufficient number of dose-limiting toxicities in the 21 patients enrolled in the trial. Conditioning with HDLEN plus HDM was associated with a favorable tolerability profile. Adverse events following ASCT were as expected with HDM. Median progression-free and overall survival were 10 months and 22 months, respectively, in this population of heavily pretreated patients. Our findings suggest that HDLEN in combination with HDM may offer significant potential as a conditioning regimen before ASCT in patients with RRMM. These preliminary findings are now being evaluated further in an ongoing phase II clinical trial. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  16. Vorinostat Combined with High-Dose Gemcitabine, Busulfan, and Melphalan with Autologous Stem Cell Transplantation in Patients with Refractory Lymphomas.

    Science.gov (United States)

    Nieto, Yago; Valdez, Benigno C; Thall, Peter F; Ahmed, Sairah; Jones, Roy B; Hosing, Chitra; Popat, Uday; Shpall, Elizabeth J; Qazilbash, Muzaffar; Gulbis, Alison; Anderlini, Paolo; Alousi, Amin; Shah, Nina; Bashir, Qaiser; Liu, Yan; Oki, Yasuhiro; Hagemeister, Frederick; Fanale, Michelle; Dabaja, Bouthaina; Pinnix, Chelsea; Champlin, Richard; Andersson, Borje S

    2015-11-01

    More active high-dose regimens are needed for refractory/poor-risk relapsed lymphomas. We previously developed a regimen of infusional gemcitabine/busulfan/melphalan, exploiting the synergistic interaction. Its encouraging activity in refractory lymphomas led us to further enhance its use as a platform for epigenetic modulation. We previously observed increased cytotoxicity in refractory lymphoma cell lines when the histone deacetylase inhibitor vorinostat was added to gemcitabine/busulfan/melphalan, which prompted us to clinically study this four-drug combination. Patients ages 12 to 65 with refractory diffuse large B cell lymphoma (DLCL), Hodgkin (HL), or T lymphoma were eligible. Vorinostat was given at 200 mg/day to 1000 mg/day (days -8 to -3). Gemcitabine was infused continuously at 10 mg/m(2)/minute over 4.5 hours (days -8 and -3). Busulfan dosing targeted 4000 μM-minute/day (days -8 to -5). Melphalan was infused at 60 mg/m(2)/day (days -3 and -2). Patients with CD20(+) tumors received rituximab (375 mg/m(2), days +1 and +8). We enrolled 78 patients: 52 DLCL, 20 HL, and 6 T lymphoma; median age 44 years (range, 15 to 65); median 3 prior chemotherapy lines (range, 2 to 7); and 48% of patients had positron emission tomography-positive tumors at high-dose chemotherapy (29% unresponsive). The vorinostat dose was safely escalated up to 1000 mg/day, with no treatment-related deaths. Toxicities included mucositis and dermatitis. Neutrophils and platelets engrafted promptly. At median follow-up of 25 (range, 16 to 41) months, event-free and overall survival were 61.5% and 73%, respectively (DLCL) and 45% and 80%, respectively (HL). In conclusion, vorinostat/gemcitabine/busulfan/melphalan is safe and highly active in refractory/poor-risk relapsed lymphomas, warranting further evaluation. This trial was registered at ClinicalTrials.gov (NCI-2011-02891). Copyright © 2015 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights

  17. Involved field radiation therapy for Hodgkin's disease autologous bone marrow transplantation regimens

    International Nuclear Information System (INIS)

    Pezner, Richard D.; Nademanee, Auayporn; Niland, Joyce C.; Vora, Nayana; Forman, Stephen J.

    1995-01-01

    From 1986 through 1992, involved-field radiation therapy (IF-RT) was administered to 29 of 86 patients with recurrent Hodgkin's disease (HD) who received a high-dose cyclophosphamide/etoposide regimen with autologous bone marrow transplantation (A-BMT). Patients without a significant history of prior RT received total body irradiation (TBI), initially as a single dose 5-7.5 Gy, and subsequently with fractionated TBI (F-TBI) delivering 12 Gy. Previously irradiated patients received a high-dose BCNU regimen instead of TBI. IF-RT was employed selectively, usually for sites of bulky disease (> 5 cm). IF-RT doses were typically 20 Gy at 2 Gy per fraction for TBI patients and 30-40 Gy at 1.8-2.0 Gy per fraction for non-TBI Patients. Fatal complications developed in four patients while second malignancies have developed in two. The region which received IF-RT was the site of first recurrence in only two cases (7%). With a median follow-up of 28 months, the two-year disease-free survival rate was 44%. For the 22 patients treated by either F-TBI or high-dose BCNU, the 2-year disease-free survival rate was 50% with a median follow up of 29 months. Selective use of IF-RT may increase the chances of complete remission and disease free survival in HD patients with a history of bulky disease

  18. High-dose therapy and autologous transplantation for lymphoma: the Peter MacCallum Cancer institute experience

    International Nuclear Information System (INIS)

    Dowling, A.J.; Prince, H.M.; Wolf, M.; Januszewicz, H.; Seymour, J.F.; Gates, P.; Wirth, A.; Juneja, S.; Smith, J.G.

    2001-01-01

    High-dose therapy (HDT) with autologous bone marrow or blood cell transplantation for the treatment of lymphoma commenced at Peter MacCallum Cancer Institute in 1986. To examine the patient characteristics and outcomes of patients with non-Hodgkin's lymphoma (NHL) and Hodgkin's disease (HD) treated with HDT and autologous transplantation at our Institute in the first 10 years of the service (1986-95). A retrospective analysis was performed examining patient characteristics, prior chemotherapy regimens, pretransplant disease status, HDT regimen, source of stem cells, time for haematopoietic recovery, complications of transplantation, response rates, overall survival (OS) and progression-free survival (PFS). Sixty-seven patients with NHL were treated with an estimated 5-year OS rate of 44% (95% confidence interval (CI) 32-56%) and PFS rate of 34% (95% CI 21-44%). Factors independently predictive of an unfavourable PFS on multivariate analyses were presence of constitutional symptoms at transplant (P < 0.002) and chemotherapy-resistant disease at transplant (P= 0.02). Twenty-three patients with HD were treated with a 5-year predicted OS rate of 74% (95% CI 56-92%) and PFS rate of 57% (95% CI 36-77%).There was no difference in PFS for HD patients who relapsed either within 12 months of completion of front-line therapy or after this time (P =0.5). The transplant-related mortality for the entire cohort was 17%, with a progressive decrease over time. HDT with autologous transplantation achieves durable PFS and OS in patients with lymphoma. Improved patient selection, therapy modifications according to prognostic factors and ongoing improvements in supportive care should improve outcomes further

  19. Treatment of small cell carcinoma of lung with combined high dose mediastinal irradiation, whole brain prophylaxis and chemotherapy

    International Nuclear Information System (INIS)

    Shank, B.; Natale, R.B.; Hilaris, B.S.; Wittes, R.E.

    1981-01-01

    Survival of patients with small cell carcinoma of lung, treated on a new combined radiotherapy-chemotherapy protocol, compares favorably with other regimens in the literature and our own previous combined approaches. Radiation, given after induction chemotherapy, consisted of whole brain prophylaxis in all 44 evaluable patients. Patients with limited disease were also treated to the primary and mediastinum to a high dose (5000 rad equivalent) using multiple fields. The new chemotherapy regimen consisted of induction with cyclophosphamide, doxorubicin, and vincristine alternated with cis-platinum and VP-16 (an epipodophyllotoxin) for two cycles, followed by consolidation with low dose cyclophosphamide and vincristine concurrent with irradiation. Patients with limited disease who achieved less than complete response, and all patients with extensive disease were not continued on maintenance chemotherapy. Out of 24 evaluable patients with limited disease, there was 73% survival at 1 year by life-table analysis, measured from treatment initiation. After induction, 16/24 of these limited disease patients were CR (complete responders): 20/24 were CR at completion of their irradiation. Out of 20 evaluable patients with extensive disease, there was 59% survival at 1 year by life-table analysis. Only 4/44 (9%) brain parenchymal relapses occurred, one at 3 months and one at 6 months after local failure and two in patients who did not become CRs, implicating a possible re-seeding mechanism. Five patients had central nervous system relapses outside of brain parenchyma (spinal epidural and leptomeningeal); in three patients this was the initial site of failure. Significant complications included leukopenia (50%) and thrombocytopenia (24%) primarily during induction, and chronic pulmonary fibrosis (25%), possibly contributing to two deaths

  20. Efficacy and tolerability of high-dose phenobarbital in children with focal seizures.

    Science.gov (United States)

    Okumura, Akihisa; Nakahara, Eri; Ikeno, Mitsuru; Abe, Shinpei; Igarashi, Ayuko; Nakazawa, Mika; Takasu, Michihiko; Shimizu, Toshiaki

    2016-04-01

    We retrospectively reviewed the outcomes of children with focal epilepsy treated with oral high-dose phenobarbital. We reviewed data on children (agedphenobarbital (>5 mg/kg/day to maintain a target serum level >40 μg/mL) for at least 6 months. Seizure frequency was evaluated after phenobarbital titration, and 1 and 2 years after high-dose phenobarbital treatment commenced. Treatment was judged effective when seizure frequencies fell by ⩾75%. Seven boys and eight girls were treated. The median age at commencement of high-dose phenobarbital therapy was 30 months. The maximal serum phenobarbital level ranged from 36.5 to 62.9 μg/mL. High-dose PB was effective in seven. In two patients, treatment was transiently effective, but seizure frequency later returned to the baseline. High-dose PB was ineffective in six. No significant association between effectiveness and any clinical variable was evident. Drowsiness was recorded in nine patients, but no patient developed a behavioral problem or hypersensitivity. Oral high-dose phenobarbital was effective in 7 of 15 patients with focal epilepsy and well tolerated. High-dose PB may be useful when surgical treatment is difficult. Copyright © 2015 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  1. Erythemal and therapeutic response of psoriasis to PUVA using high-dose UVA

    International Nuclear Information System (INIS)

    Speight, E.L.; Farr, P.M.

    1994-01-01

    In PUVA treatment of psoriasis, clinical observation suggests that uninvolved skin is more susceptible to PUVA erythema than lesions of psoriasis. If this is the case, then the efficacy of PUVA treatment might be increased by using localized high-dose UVA restricted to lesional skin. We have therefore studied the erythemal and therapeutic response of psoriasis to PUVA using high-dose UVA and, for comparison, the erythemal response to UVB. This study demonstrates that psoriasis may clear rapidly, without burning, using high-dose UVA. Availability of a suitable irradiation apparatus would allow rapid and effective PUVA treatment to be used for localized, resistant disease. (author)

  2. Cumulative high doses of inhaled formoterol have less systemic effects in asthmatic children 6-11 years-old than cumulative high doses of inhaled terbutaline

    DEFF Research Database (Denmark)

    Kaae, Rikke; Agertoft, Lone; Pedersen, Sören

    2004-01-01

    OBJECTIVES: To evaluate high dose tolerability and relative systemic dose potency between inhaled clinically equipotent dose increments of formoterol and terbutaline in children. METHODS: Twenty boys and girls (6-11 years-old) with asthma and normal ECGs were studied. Ten doses of formoterol (Oxi...

  3. Successful Hematopoietic Stem Cell Transplantation Following a Cyclophosphamide-Containing Preparative Regimen with Concomitant Phenobarbital Administration

    Directory of Open Access Journals (Sweden)

    Catherine Weber

    2012-01-01

    Full Text Available Cyclophosphamide is an immunosuppressive agent and an anticancer prodrug which requires bioactivation catalyzed primarily by cytochrome P450 enzymes in order to be transformed into its active alkylating compounds. Concomitant administration of drugs known to inhibit or induce this enzyme system is a clinical concern. Herein, we present the case of a chronically ill 21-year-old patient who received high-dose cyclophosphamide, equine antithymocyte globulin (eATG, and total body irradiation (TBI followed by an allogeneic hematopoietic stem cell transplant (HSCT for severe aplastic anemia. Throughout her hospitalization, she continued to receive quadruple anticonvulsant therapy including phenobarbital for her long-standing seizure history. The preparative regimen was tolerated well aside from a hypersensitivity reaction to eATG, and minimal cyclophosphamide-related toxicities. Safe and effective administration of high-dose cyclophosphamide was possible with multidisciplinary care consisting of physician, nursing, pharmacy, neurology consultation, as well as social work and case management.

  4. Successful hematopoietic stem cell transplantation following a cyclophosphamide-containing preparative regimen with concomitant phenobarbital administration.

    Science.gov (United States)

    Weber, Catherine; Kasberg, Heather; Copelan, Edward

    2012-01-01

    Cyclophosphamide is an immunosuppressive agent and an anticancer prodrug which requires bioactivation catalyzed primarily by cytochrome P450 enzymes in order to be transformed into its active alkylating compounds. Concomitant administration of drugs known to inhibit or induce this enzyme system is a clinical concern. Herein, we present the case of a chronically ill 21-year-old patient who received high-dose cyclophosphamide, equine antithymocyte globulin (eATG), and total body irradiation (TBI) followed by an allogeneic hematopoietic stem cell transplant (HSCT) for severe aplastic anemia. Throughout her hospitalization, she continued to receive quadruple anticonvulsant therapy including phenobarbital for her long-standing seizure history. The preparative regimen was tolerated well aside from a hypersensitivity reaction to eATG, and minimal cyclophosphamide-related toxicities. Safe and effective administration of high-dose cyclophosphamide was possible with multidisciplinary care consisting of physician, nursing, pharmacy, neurology consultation, as well as social work and case management.

  5. High-dose-rate brachytherapy with two or three fractions as monotherapy in the treatment of locally advanced prostate cancer

    International Nuclear Information System (INIS)

    Hoskin, Peter; Rojas, Ana; Ostler, Peter; Hughes, Robert; Alonzi, Roberto; Lowe, Gerry; Bryant, Linda

    2014-01-01

    Background: To evaluate late urinary (GU) and gastrointestinal (GI) adverse events (AEs) and biochemical control of disease after high-dose rate brachytherapy (HDR-BT) in locally advanced prostate cancer. Patients and methods: 227 consecutive patients were treated with 3 × 10.5 Gy (n = 109) or 2 × 13 Gy (n = 118) HDR-BT alone. Biochemical failure was assessed using the Phoenix definition of PSA nadir + 2 μg/l and late AEs using the RTOG scoring system and the International Prostate Symptom Score (IPSS). Results: Kaplan–Meier estimates and prevalence of late events indicate that urinary, bowel and IPSS symptoms are higher after 31.5 Gy than after 26 Gy, however differences are significant only for Grade 1 and 2 urinary toxicity. Kaplan–Meier estimates of morbidity are consistently and considerably higher than time-point estimates of prevalence; which reflects the transient nature of most symptoms. At 3 years 93% and 97% of patients treated with 26 and 31.5 Gy, respectively, were free from biochemical relapse (p = 0.5) and 91% for the latter regimen at 5 years. In univariate and multivariate analysis risk-category was the only significant predictor of relapse (p < 0.03). Conclusion: These HDR-BT schedules achieved high levels of biochemical control of disease in patients with advanced prostate cancer with few severe complications seen throughout the first 3 years

  6. Population PK/PD model of homocysteine concentrations after high-dose methotrexate treatment in patients with acute lymphoblastic leukemia.

    Directory of Open Access Journals (Sweden)

    Hauke Rühs

    Full Text Available Elevated homocysteine concentrations have been associated with methotrexate-induced neurotoxicity. Based on methotrexate and homocysteine plasma concentrations of 494 children with acute lymphoblastic leukemia treated with high-dose methotrexate in the TOTAL XV study, a pharmacokinetic/pharmacodynamic (PK/PD model was built with NONMEM. Several compartment and indirect response models were investigated. The pharmacokinetic disposition of methotrexate was best described by a two-compartment model. Homocysteine concentrations were included by an indirect response model where methotrexate inhibition of the homocysteine elimination rate was described by an E(max model. The homocysteine baseline level was found to be age-dependent. Simulations revealed that folinate rescue therapy does not affect peak concentrations of homocysteine but leads to a modestly reduced homocysteine exposure. In conclusion, our PK/PD model describes the increase of methotrexate-induced HCY concentrations with satisfactory precision and can be applied to assess the effect of folinate regimens on the HCY concentration-time course.

  7. High-dose zolpidem dependence - Psychostimulant effects? A case report and literature review

    Directory of Open Access Journals (Sweden)

    Abhijna Chandan Chattopadhyay

    2016-01-01

    Full Text Available Zolpidem, an imidazoline nonbenzodiazepine sedative drug, is used widely. Initial reports showed minimal abuse potential. However, multiple reports have appeared of dose escalation and abuse. Subjective effects of high-dose zolpidem are not known. In light of accumulating evidence of abuse potential, we hereby report a case of high-dose dependence and a review of relevant literature. A 33-year-old male presented with 5 years of daily use of 600–1700 mg of zolpidem tartrate. He reported subjective effects of euphoria, intense craving, and inability to stop use. Loss of receptor specificity, pharmacokinetic factors, and different receptor distributions can explain paradoxical stimulatory effects of high-dose zolpidem. Further studies are required to characterize subjective effects of high-dose zolpidem.

  8. Acute effects of high-dose furosemide on residual renal function in CAPD patients

    NARCIS (Netherlands)

    van Olden, Rudolf W.; Guchelaar, Henk-Jan; Struijk, Dirk G.; Krediet, Raymond T.; Arisz, Lambertus

    2003-01-01

    BACKGROUND: High doses of furosemide can increase urine volume in chronic peritoneal dialysis (CAPD) patients. However, no information is available about effects on urinary solute excretion in relation to residual glomerular filtration rate (GFR), urinary furosemide excretion, and peritoneal solute

  9. Safety aspects of preoperative high-dose glucocorticoid in primary total knee replacement

    DEFF Research Database (Denmark)

    Jørgensen, C C; Pitter, F T; Kehlet, H

    2017-01-01

    Background: Preoperative single high-dose glucocorticoid may have early outcome benefits in total hip arthroplasty (THA) and knee arthroplasty (TKA), but long-term safety aspects have not been evaluated. Methods: From October 2013, the departments reporting to the prospective Lundbeck Foundation....... Conclusions: In this detailed prospective cohort study, preoperative high-dose glucocorticoid administration was not associated with LOS >4 days, readmissions or infectious complications in TKA patients without contraindications....

  10. Evaluation of functioning of high dose rate brachytherapy at the Instituto Nacional do Cancer

    International Nuclear Information System (INIS)

    Guedes, Laura M.A.; Barreto, Rodrigo V.; Silva, Penha M.; Macedo, Afranio A.; Borges, Solange C.; Martinez, Valeria P.O.

    2001-01-01

    Quality control tests are very useful tools to assure the quality of patient's treatment. A daily control of the high dose rate micro selectron was performed based on the security parameters of the equipment and on the quickness of performance. The purpose of this report is to evaluate and to discuss the errors found during the first three years with the high dose rate brachytherapy, at the Instituto Nacional de Cancer. (author)

  11. High-dose Sulbactam Treatment for Ventilator-Associated Pneumonia Caused by Carbapenem-Resistant

    Directory of Open Access Journals (Sweden)

    In Beom Jeong

    2016-11-01

    Full Text Available Background Several antibiotics can be used to treat ventilator-associated pneumonia caused by carbapenem-resistant A. baumannii (CRAB-VAP including high-dose sulbactam. However, the effectiveness of high-dose sulbactam therapy is not well known. We report our experience with high-dose sulbactam for treatment of CRAB-VAP. Methods Medical records of patients with CRAB-VAP who were given high-dose sulbactam between May 2013 and June 2015 were reviewed. Results Fifty-eight patients with CRAB-VAP were treated with high-dose sulbactam. The mean age was 72.0 ± 15.2 years, and the acute physiology and chronic health evaluation II (APACHE II score was 15.1 ± 5.10 at the time of CRAB-VAP diagnosis. Early clinical improvement was observed in 65.5% of patients, and 30-day mortality was 29.3%. Early clinical failure (odds ratio [OR]: 8.720, confidence interval [CI]: 1.346-56.484; p = 0.023 and APACHE II score ≥ 14 at CRAB-VAP diagnosis (OR: 10.934, CI: 1.047-114.148; p = 0.046 were associated with 30-day mortality. Conclusions High-dose sulbactam therapy may be effective for the treatment of CRAB-VAP. However, early clinical failure was observed in 35% of patients and was associated with poor outcome.

  12. Transperineal high-dose-rate interstitial radiation therapy in the management of gynecologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Itami, Jun; Hara, Ryuseke; Kozuka, Takuyou; Yamashita, Hideomi; Nakajima, Kaori; Shibata, Kouji; Abe, Yoshihisa; Fuse, Masashi; Ito, Masashi [International Medical Center of Japan, Tokyo (Japan). Dept. of Radiation Therapy and Oncology

    2003-11-01

    Background: High-dose-rate interstitial radiation therapy is a newly introduced modality, and its role in the management of gynecologic malignancies remains to be studied. Clinical experience in high-dose-rate interstitial radiation therapy was retrospectively investigated. Patients and Methods: Eight patients with primary and nine with recurrent gynecologic malignancies underwent high-dose-rate interstitial radiation therapy with/without external-beam irradiation. Fractional dose of the high-dose-rate interstitial radiation therapy ranged between 4 and 6 Gy with total doses of 15-54 Gy. Interstitial irradiation was performed twice daily with an interval of > 6 h. Results: 2-year local control rate was 75% for primary treatment and 47% for treatment of recurrence (p = 0.46). Maximum tumor size had a statistically significant impact on local control (p < 0.002). Grade 2 and 4 late complications were seen in five patients, and the incidence was significantly higher in patients with a larger volume enclosed by the prescribed fractional dose of high-dose-rate interstitial radiation therapy. The incidence of grade 2 and 4 complications at 18 months was 78% and 0% with a volume > 100 cm{sup 3} and {<=} 100 cm{sup 3}, respectively (p < 0.04). Conclusion: Although high-dose-rate interstitial radiation therapy is a promising modality, it must be applied cautiously to patients with bulky tumors because of the high incidence of serious complications. (orig.)

  13. Cycloplegic Refraction in Hyperopic Children: Effectiveness of a 0.5% Tropicamide and 0.5% Phenylephrine Addition to 1% Cyclopentolate Regimen.

    Science.gov (United States)

    Yoo, Seul Gi; Cho, Myung Jin; Kim, Ungsoo Samuel; Baek, Seung Hee

    2017-06-01

    To evaluate the effectiveness of a cycloplegic regimen using 0.5% tropicamide and 0.5% phenylephrine (Tropherine, Hanmi Pharm), in addition to 1% cyclopentolate, in hyperopic children. The medical records of hyperopic patients below the age of 14 years who had undergone cycloplegic retinoscopy were retrospectively reviewed. Cycloplegic refractions were performed using one of two cycloplegic regimens. Regimen 1 was a Tropherine-added regimen comprising the administration of one drop of 1% cyclopentolate followed by two to three drops of Tropherine added at 15-minute intervals. Regimen 2 was a cyclopentolate-only regimen comprising the administration of three to four drops of 1% cyclopentolate at 15-minute intervals. The mean difference between noncycloplegic and cycloplegic refraction was compared between the two regimens. A total of 308 eyes of 308 hyperopic children were included. The mean difference (±standard deviation) in the spherical equivalent (SE) between cycloplegic and noncycloplegic refraction was significantly larger in regimen 2 than in regimen 1, with values of +1.70 ± 1.03 diopters (D) and +1.25 ± 0.89 D, respectively (p=0.001). The SE change after cycloplegia was significantly different between the two regimens only in patients aged 5 years or younger (p=0.001), particularly in those with high hyperopia with an SE ≥5 D (p=0.005) or fully accommodative esotropia (p=0.009). There was no significant difference between the two regimens in patients older than 5 years, regardless of the presence of high hyperopia or fully accommodative esotropia. The Tropherine-added regimen exerted a weaker cycloplegic effect than the cyclopentolate-only regimen, particularly in children under the age of 5 years with high hyperopia or fully accommodative esotropia. However, the difference in refraction between the two regimens was small. A Tropherine-added regimen can be effective in hyperopic children, with less associated discomfort than the instillation of

  14. Compositions comprising free-standing two-dimensional nanocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Barsoum, Michel W.; Gogotsi, Yury; Abdelmalak, Michael Naguib; Mashtalir, Olha

    2017-12-05

    The present invention is directed to methods of transferring urea from an aqueous solution comprising urea to a MXene composition, the method comprising contacting the aqueous solution comprising urea with the MXene composition for a time sufficient to form an intercalated MXene composition comprising urea.

  15. Comparison of fixed low dose versus high dose radioactive iodine for the treatment of hyperthyroidism: retrospective multifactorial analysis impacting the outcome of therapy

    International Nuclear Information System (INIS)

    Suresh Kumar, A.C.; Malhotra, G.; Basu, S.; Asopa, R.V.

    2010-01-01

    Full text: Radioactive iodine ( 131 I) as a fixed dose protocol is widely used for treatment of hyperthyroidism. However, there is no consensus on the best optimum dose for an individual patient. The objectives of this study were to observe the outcome of 131 I therapy in patients of primary hyperthyroidism in relation to fixed low dose versus high dose regimen, impact of antithyroid drugs and influence of thyroid gland size on therapy outcome. Materials and Methods: Study design: Retrospective analysis. Study group included 287 diagnosed patients of primary hyperthyroidism who had undergone 131 I therapy for the first time (68 M, 219 F; Mean age ± S.D.: 43.84 ± 12.53). All patients with low RAIU, thyrocardiac disease were excluded. Details of antithyroid (ATD) drug treatment were recorded. Analysis was done from 2002 till patients became euthyroid/hypothyroid or until January 2010. Each patient's response was evaluated initially at 6 weeks and thereafter every three months. Appropriate statistical tests were applied to compare treatment response between the groups. A P value<0.05 was considered significant. Results: Of 287 patients, 209 patients had been administered low dose (Mean ± S.D.: 4.68 ± 0.62 mCi) while 78 patients had received high dose (Mean ± S.D.: 9.15 ± 1.05 mCi) of radioiodine. 57.9% (121/ 209) patients in the low dose group responded as compared to 75.6% (59/78) in high dose group after a follow up of more than 36 months. Similarly, among patients with and without antithyroid drug treatment, grade II and above goiters the response rates were significantly higher for high dose group as compared to low dose group. Conclusion: We suggest that high dose radioiodine treatment with 8 to 10 mCi is effective in treating hyperthyroidism in patients with a better success rate than the low dose treatment with 3 to 5 mCi. This is also likely to be helpful in patients who have not received antithyroid drugs. It appears that clinically relevant

  16. High dose vitamin D may improve lower urinary tract symptoms in postmenopausal women.

    Science.gov (United States)

    Oberg, Johanna; Verelst, Margareta; Jorde, Rolf; Cashman, Kevin; Grimnes, Guri

    2017-10-01

    Lower urinary tract symptoms (LUTS) are common in postmenopausal women, and have been reported inversely associated with vitamin D intake and serum 25-hydroxyvitamin D (25(OH)D) levels. The aim of this study was to investigate if high dose vitamin D supplementation would affect LUTS in comparison to standard dose. In a randomized controlled study including 297 postmenopausal women with low bone mineral density, the participants were allocated to receive capsules of 20 000IU of vitamin D 3 twice a week (high dose group) or similar looking placebo (standard dose group). In addition, all the participants received 1g of calcium and 800IU of vitamin D daily. A validated questionnaire regarding LUTS was filled in at baseline and after 12 months. At baseline, 76 women in the high dose group and 82 in the standard dose group reported any LUTS. Levels of serum 25(OH)D increased significantly more in the high dose group (from 64.7 to 164.1nmol/l compared to from 64.1 to 81.8nmol/l, p<0.01). No differences between the groups were seen regarding change in LUTS except for a statistically significant reduction in the reported severity of urine incontinence in the high dose group as compared to the standard dose group after one year (p<0.05). The results need confirmation in a study specifically designed for this purpose. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. High-dose gadolinium-enhanced MRI for diagnosis of meningeal metastases

    International Nuclear Information System (INIS)

    Kallmes, D.F.; Gray, L.; Glass, J.P.

    1998-01-01

    We compared high-dose (0.3 mmol/kg) and standard-dose (0.1 mmol/kg) gadolinium-enhanced MRI for diagnosis of meningeal metastases in 12 patients with suspected meningeal metastases. They were imaged with both standard-dose and high-dose gadolinium. All patients with abnormal meningeal enhancement underwent at least one lumbar puncture for cerebrospinal fluid (CSF) cytology, while patients with normal meningeal enhancement were followed clinically. All patients with negative CSF cytology also were followed clinically. A single observer reviewed all the images, with specific attention to the enhancement pattern of the meninges. Abnormal leptomeningeal enhancement was present in three cases, and abnormal pachymeningeal enhancement in three other patients. All of these patients had abnormal CSF analyses. In two of the three cases of abnormal leptomeningeal enhancement the disease was more evident on high-dose than on standard-dose imaging; in one case the abnormal enhancement was visible only on high-dose imaging. In one of the three cases with abnormal pachymeningeal enhancement, the disease was evident prospectively only with high-dose imaging. (orig.)

  18. New Treatment Regimen for Latent Tuberculosis Infection

    Centers for Disease Control (CDC) Podcasts

    In this podcast, Dr. Kenneth Castro, Director of the Division of Tuberculosis Elimination, discusses the December 9, 2011 CDC guidelines for the use of a new regimen for the treatment of persons with latent tuberculosis infection.

  19. Mechanism of action for anti-radiation vaccine in reducing the biological impact of high-dose gamma irradiation

    Science.gov (United States)

    Maliev, Vladislav; Popov, Dmitri; Jones, Jeffrey A.; Casey, Rachael C.

    Ionizing radiation is a major health risk of long-term space travel, the biological consequences of which include genetic and oxidative damage. In this study, we propose an original mechanism by which high doses of ionizing radiation induce acute toxicity. We identified biological components that appear in the lymphatic vessels shortly after high-dose gamma irradiation. These radiation-induced toxins, which we have named specific radiation determinants (SRD), were generated in the irradiated tissues and then circulated throughout the body via the lymph circulation and bloodstream. Depending on the type of SRD elicited, different syndromes of acute radiation sickness (ARS) were expressed. The SRDs were developed into a vaccine used to confer active immunity against acute radiation toxicity in immunologically naïve animals. Animals that were pretreated with SRDs exhibited resistance to lethal doses of gamma radiation, as measured by increased survival times and survival rates. In comparison, untreated animals that were exposed to similar large doses of gamma radiation developed acute radiation sickness and died within days. This phenomenon was observed in a number of mammalian species. Initial analysis of the biochemical characteristics indicated that the SRDs were large molecular weight (200-250 kDa) molecules that were comprised of a mixture of protein, lipid, carbohydrate, and mineral. Further analysis is required to further identify the SRD molecules and the biological mechanism by which they mediate the toxicity associated with acute radiation sickness. By doing so, we may develop an effective specific immunoprophylaxis as a countermeasure against the acute effects of ionizing radiation.

  20. In an animal model nephrogenic systemic fibrosis cannot be induced by intraperitoneal injection of high-dose gadolinium based contrast agents

    International Nuclear Information System (INIS)

    Langer, R.D.; Lorke, D.E.; Neidl van Gorkom, K.F.; Petroianu, G.; Azimullah, S.; Nurulain, S.M.; Singh, S.; Fuchsjäger, M.

    2012-01-01

    Aim and objective: Nephrogenic systemic fibrosis (NSF) has been reported in humans to be most likely induced by gadolinium based contrast agents (GBCA), namely by gadodiamide, gadopentetate dimeglumine, and gadoversetamide, rarely by other GBCA. The pathogenesis of NSF remains unclear; different hypotheses are under discussion. The objective of the study is to assess if in the animal model human-like NSF changes can be induced by high-dose, intraperitoneal GBCA injections over four weeks. Materials and methods: After approval by the institutional animal ethics committee, six rats each were randomly assigned to groups, and treated with seven different GBCA. Intraperitoneal (IP) injections – proven in the animal model to be effective – were chosen to prolong the animals’ exposure to the respective GBCA. GBCA doses of previous intravenous (IV) animal studies were applied. After five weeks all rats were sacrificed. Sham controls were treated with IP saline injections, employing the same regimen. Results: No findings comparable with human NSF were observed in all animals after IP treatment with all seven GBCA at daily doses of 2.5 and 5.0 mmol/kg body weight (BW). No histopathological abnormalities of all examined organs were noted. Weight loss was stated in weeks three and four with GBCA injections at doses of 5.0 mmol/kg BW, but rats regained weight after cessation of GBCA treatment. Conclusions: NSF-comparable pathological findings could not be induced by high dose intraperitoneal injection of seven GBCA

  1. In an animal model nephrogenic systemic fibrosis cannot be induced by intraperitoneal injection of high-dose gadolinium based contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Langer, R.D., E-mail: rlanger@uaeu.ac.ae [Faculty of Medicine and Health Sciences (FMHS), United Arab Emirates University, Al Ain (United Arab Emirates); Lorke, D.E. [Florida International University, Miami, FL (United States); Neidl van Gorkom, K.F. [Faculty of Medicine and Health Sciences (FMHS), United Arab Emirates University, Al Ain (United Arab Emirates); Petroianu, G. [Florida International University, Miami, FL (United States); Azimullah, S.; Nurulain, S.M.; Singh, S. [Faculty of Medicine and Health Sciences (FMHS), United Arab Emirates University, Al Ain (United Arab Emirates); Fuchsjäger, M. [Al Ain Hospital, MUV-VAMED, Al Ain (United Arab Emirates)

    2012-10-15

    Aim and objective: Nephrogenic systemic fibrosis (NSF) has been reported in humans to be most likely induced by gadolinium based contrast agents (GBCA), namely by gadodiamide, gadopentetate dimeglumine, and gadoversetamide, rarely by other GBCA. The pathogenesis of NSF remains unclear; different hypotheses are under discussion. The objective of the study is to assess if in the animal model human-like NSF changes can be induced by high-dose, intraperitoneal GBCA injections over four weeks. Materials and methods: After approval by the institutional animal ethics committee, six rats each were randomly assigned to groups, and treated with seven different GBCA. Intraperitoneal (IP) injections – proven in the animal model to be effective – were chosen to prolong the animals’ exposure to the respective GBCA. GBCA doses of previous intravenous (IV) animal studies were applied. After five weeks all rats were sacrificed. Sham controls were treated with IP saline injections, employing the same regimen. Results: No findings comparable with human NSF were observed in all animals after IP treatment with all seven GBCA at daily doses of 2.5 and 5.0 mmol/kg body weight (BW). No histopathological abnormalities of all examined organs were noted. Weight loss was stated in weeks three and four with GBCA injections at doses of 5.0 mmol/kg BW, but rats regained weight after cessation of GBCA treatment. Conclusions: NSF-comparable pathological findings could not be induced by high dose intraperitoneal injection of seven GBCA.

  2. A Phase I Study of Pulse High-Dose Vorinostat (V) plus Rituximab (R), Ifosphamide, Carboplatin, and Etoposide (ICE) in Patients with Relapsed Lymphoma

    Science.gov (United States)

    Budde, Lihua E.; Zhang, Michelle M.; Shustov, Andrei R.; Pagel, John M.; Gooley, Ted A.; Oliveira, George R.; Chen, Tara L.; Knudsen, Nancy L.; Roden, Jennifer E.; Kammerer, Britt E.; Frayo, Shani L.; Warr, Thomas A.; Boyd, Thomas E.; Press, Oliver W.; Gopal, Ajay K.

    2013-01-01

    SUMMARY Given the poor outcomes of relapsed aggressive lymphomas and preclinical data suggesting that ≥2.5 μM concentrations of vorinostat synergize with both etoposide and platinums, we hypothesized that pulse high-dose vorinostat could safely augment the anti-tumour activity of (R)ICE [(rituximab), ifosphamide, carboplatin, etoposide] chemotherapy. We conducted a phase I dose escalation study using a schedule with oral vorinostat ranging from 400 mg/d to 700 mg bid for 5 days in combination with the standard (R)ICE regimen (days 3, 4 and 5). Twenty-nine patients (median age 56 years, median 2 prior therapies, 14 chemoresistant [of 27 evaluable], 2 prior transplants) were enrolled and treated. The maximally tolerated vorinostat dose was defined as 500 mg twice daily × 5 days. Common dose limiting toxicities included infection (n=2), hypokalaemia (n=2), and transaminitis (n=2). Grade 3 related gastrointestinal toxicity was seen in 9 patients. The median vorinostat concentration on day 3 was 4.5 μM (range 4.2–6.0 μM) and in vitro data confirmed the augmented antitumour and histone acetylation activity at these levels. Responses were observed in 19 of 27 evaluable patients (70%) including 8 complete response/unconfirmed complete response. High-dose vorinostat can be delivered safely with (R)ICE, achieves potentially synergistic drug levels, and warrants further study, although adequate gastrointestinal prophylaxis is warranted. PMID:23356514

  3. Results in patients treated with high-dose-rate interstitial brachytherapy for oral tongue cancer

    International Nuclear Information System (INIS)

    Yamamoto, Michinori; Shirane, Makoto; Ueda, Tsutomu; Miyahara, Nobuyuki

    2006-01-01

    Eight patients were treated with high-dose-rate interstitial brachytherapy for oral tongue cancer between September 2000 and August 2004. The patient distribution was 1 T1, 5 T2, 1 T3, and 1 T4a. Patients received 50-60 Gy in 10 fractions over seven days with high-dose-rate brachytherapy. Six of the eight patients were treated with a combination of external beam radiotherapy (20-30 Gy) and interstitial brachytherapy. The two-year primary local control rate was 83% for initial case. High-dose-rate brachytherapy was performed safely even for an aged person, and was a useful treatment modality for oral tongue cancer. (author)

  4. High dose therapy with autologous stem cell support in malignant disorders

    International Nuclear Information System (INIS)

    Holte, H.; Kvaloey, S.O.; Engan, T.

    1996-01-01

    New biomedical knowledge may improve the diagnostic procedures and treatment provided by the Health Services, but at additional cost. In a social democratic health care system, the hospital budgets have no room for expensive, new procedures or treatments, unless these are funded through extra allocation from the central authorities. High dose therapy with autologous stem cell support in malignant disorders is an example of a new and promising, but rather expensive treatment, but its role in cancer therapy has yet to be established. The indications for testing high dose therapy with autologous stem cell support in various malignancies are discussed, with emphasis on the principles for deciding which categories of disease should have priority. The authors suggest some malignant disorder for which high dose therapy with stem cell support should be explored versus conventional treatment in randomized prospective trials. 8 refs., 1 tab

  5. Plasma Doping - Enabling Technology for High Dose Logic and Memory Applications

    International Nuclear Information System (INIS)

    Miller, T.; Godet, L.; Papasouliotis, G. D.; Singh, V.

    2008-01-01

    As logic and memory device dimensions shrink with each generation, there are more high dose implants at lower energies. Examples include dual poly gate (also referred to as counter-doped poly), elevated source drain and contact plug implants. Plasma Doping technology throughput and dopant profile benefits at these ultra high dose and lower energy conditions have been well established [1,2,3]. For the first time a production-worthy plasma doping implanter, the VIISta PLAD tool, has been developed with unique architecture suited for precise and repeatable dopant placement. Critical elements of the architecture include pulsed DC wafer bias, closed-loop dosimetry and a uniform low energy, high density plasma source. In this paper key performance metrics such as dose uniformity, dose repeatability and dopant profile control will be presented that demonstrate the production-worthiness of the VIISta PLAD tool for several high dose applications.

  6. Factors impacting short and long-term kidney graft survival: modification by single intra-operative -high-dose induction with ATG-Fresenius.

    Science.gov (United States)

    Kaden, Jürgen; May, Gottfried; Völp, Andreas; Wesslau, Claus

    2011-01-01

    A majority of recipients benefited from the intra-operative single high-dose induction (HDI) with ATG-Fresenius (ATG-F) still leaving a group of recipients who did not profit from this kind of induction. Therefore the aim of this retrospective analysis was 1st to identify the risk factors impacting short and long-term graft survival, and 2nd to assess the efficacy of this type of induction in kidney graft recipients with or without these risk factors. A total of 606 recipients receiving two different immunosuppressive treatment regimens (1st: Triple drug therapy [TDT, n=196] consisting mainly of steroids, azathioprine and cyclosporine; 2nd: TDT + 9 mg/kg ATG-F intra-operatively [HDI, n=410]) were included in this analysis and grouped according to their kidney graft survival time (short GST: ≤1 yr, n=100 and long GST: >5 yrs, n=506). The main risk factors associated with a shortened graft survival were pre-transplant sensitization, re-transplantation, rejections (in particular vascular or mixed ones) and the necessity of a long-term anti-rejection therapy. Adding ATG-F single high dose induction to TDT was more efficient in prolonging kidney graft survival than TDT alone not only in recipients without any risk factors (p<0.005) but also in recipients with at least one risk factor (p<0.021). Only in 4.6% of recipients having two or more risk factors this effect could not be demonstrated. The intra-operative single high-dose induction with ATG-F significantly improves the kidney graft survival in recipients with or without risk factors and can therefore be recommended.

  7. Widespread increases in malondialdehyde immunoreactivity in dopamine-rich and dopamine-poor regions of rat brain following multiple, high doses of methamphetamine.

    Directory of Open Access Journals (Sweden)

    Kristen Ashley eHorner

    2011-05-01

    Full Text Available Treatment with multiple high doses of methamphetamine (METH can induce oxidative damage, including dopamine (DA-mediated reactive oxygen species (ROS formation, which may contribute to the neurotoxic damage of monoamine neurons and long-term depletion of DA in the caudate putamen (CPu and substantia nigra pars compacta (SNpc. Malondialdehyde (MDA, a product of lipid peroxidation by ROS, is commonly used as a marker of oxidative damage and treatment with multiple high doses of METH increases MDA reactivity in the CPu of humans and experimental animals. Recent data indicate that MDA itself may contribute to the destruction of DA neurons, as MDA causes the accumulation of toxic intermediates of DA metabolism via its chemical modification of the enzymes necessary for the breakdown of DA. However, it has been shown that in human METH abusers there is also increased MDA reactivity in the frontal cortex, which receives relatively fewer DA afferents than the CPu. These data suggest that METH may induce neuronal damage regardless of the regional density of DA or origin of DA input. The goal of the current study was to examine the modification of proteins by MDA in the DA-rich nigrostriatal and mesoaccumbal systems, as well as the less DA-dense cortex and hippocampus following a neurotoxic regimen of METH treatment. Animals were treated with METH (10 mg/kg every 2h for 6h, sacrificed one week later, and examined using immunocytochemistry for changes in MDA-adducted proteins. Multiple, high doses of METH significantly increased MDA immunoreactivity (MDA-ir in the CPu, SNpc, cortex and hippocampus. Multiple METH administration also increased MDA-ir in the ventral tegmental area (VTA and nucleus accumbens (NAc. Our data indicate that multiple METH treatment can induce persistent and widespread neuronal damage that may not necessarily be limited to the nigrostriatal DA system.

  8. Moderate- vs high-dose methadone in the treatment of opioid dependence: a randomized trial.

    Science.gov (United States)

    Strain, E C; Bigelow, G E; Liebson, I A; Stitzer, M L

    1999-03-17

    Methadone hydrochloride treatment is the most common pharmacological intervention for opioid dependence, and recent interest has focused on expanding methadone treatment availability beyond traditional specially licensed clinics. However, despite recommendations regarding effective dosing of methadone, controlled clinical trials of higher-dose methadone have not been conducted. To compare the relative clinical efficacy of moderate- vs high-dose methadone in the treatment of opioid dependence. A 40-week randomized, double-blind clinical trial starting in June 1992 and ending in October 1995. Outpatient substance abuse treatment research clinic at the Johns Hopkins University Bayview Campus, Baltimore, Md. One hundred ninety-two eligible clinic patients. Daily oral methadone hydrochloride in the dose range of 40 to 50 mg (n = 97) or 80 to 100 mg (n = 95), with concurrent substance abuse counseling. Opioid-positive urinalysis results and retention in treatment. By intent-to-treat analysis through week 30 patients in the high-dose group had significantly lower rates of opioid-positive urine samples compared with patients in the moderate-dose group (53.0% [95% confidence interval [CI], 46.9%-59.2%] vs 61.9% [95% CI, 55.9%-68.0%]; P = .047. These differences persisted during withdrawal from methadone. Through day 210 no significant difference was evident between dose groups in treatment retention (high-dose group mean retention, 159 days; moderate-dose group mean retention, 157 days). Nineteen (33%) of 57 patients in the high-dose group and 11 (20%) of 54 patients in the moderate-dose group completed detoxification. Both moderate- and high-dose methadone treatment resulted in decreased illicit opioid use during methadone maintenance and detoxification. The high-dose group had significantly greater decreases in illicit opioid use.

  9. Experimental research on fresh mussel meat irradiated by high-dose electron beam

    International Nuclear Information System (INIS)

    Xiao Lin; Lu Ruifeng; Hu Huachao; Wang Chaoqi; Liu Yanna

    2011-01-01

    The sterilization storage of fresh mussel irradiated high-dose electron beam was studied. From the subjective assessment by the weighted average of the test and other determined parameters, it can be concluded that the flavor of fresh mussel meat sealed canned food irradiated by high-dose electron beam has not been significant affected, and various micro-organisms can be killed effectively, which means that the irradiated fresh mussel meat can be preserved for long-term at room temperature. Therefore the method might resolve the problems induced by traditional frozen preservation methods. (authors)

  10. Statistical behavior of high doses in medical radiodiagnosis; Comportamento estatistico das altas doses em radiodiagnostico medico

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, Adriana Elisa, E-mail: adrianaebarboza@gmail.com, E-mail: elisa@bolsista.ird.gov.br [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    This work has as main purpose statistically estimating occupational exposure in medical diagnostic radiology in cases of high doses recorded in 2011 at national level. For statistical survey of this study, doses of 372 IOE's diagnostic radiology in different Brazilian states were evaluated. Data were extracted from the work of monograph (Research Methodology Of High Doses In Medical Radiodiagnostic) that contains the database's information Sector Management doses of IRD/CNEN-RJ, Brazil. The identification of these states allows the Sanitary Surveillance (VISA) responsible, becomes aware of events and work with programs to reduce these events. (author)

  11. Analysis of volatile organic compounds and sensory characteristics of pork loin samples irradiated to high doses

    International Nuclear Information System (INIS)

    Hou Zhengchi; Sun Dakuan; Qin Zongying; Jin Jiang; Zhu Liandi; Yao Side; Sheng Kanglong

    2005-01-01

    Fresh pork loin samples, protein enzyme inactivated at (72 ± 3) degree C and vacuum packaged, were irradiated to up to 45 kGy at -20 degree C by 60 Co γ-rays. The irradiated samples were examined by various kinds of method to study high dose irradiation effects of sensory changes (meat color and off-odor), transverse shearing strength, weight loss in steam cooking, volatile organic compounds, and lipid oxidation. The results showed that the high dose irradiation produced no serious effects to the pork loin samples, and volunteer responses showed fine acceptability to the irradiated meat. (authors)

  12. Evaluation of glasses containing cadmium for high dose dosimetry by the thermoluminescence technique

    International Nuclear Information System (INIS)

    Carvalho, Gabriel Soares Marchiori de; Ferreira, Pamela Zati; Cunha, Diego Merigue da; Dantas, Noelio Oliveira; Silva, Anielle C.A.; Perini, Ana Paula; Neves, Lucio Pereira; Carrera, Betzabel Noemi Silva; Watanabe, Shigueo

    2016-01-01

    New glass matrices were evaluated for high dose dosimetry by the thermoluminescence technique. Their nominal composition are 20Li_2CO_3.10Al_2O_3.15CdO.55B_2O_3 and 20Li_2CO_3.10Al_2O_3.20CdO.50B_2O_3 (mol%). The glass matrices were irradiated with different doses: 50, 100, 200, 500, 700 and 900 Gy, and the thermoluminescence emission curves were obtained for each of these values. The results show a great potential of using these matrices in high dose dosimetry. (author)

  13. Salvage high-dose-rate brachytherapy for local prostate cancer recurrence after radical radiotherapy

    Directory of Open Access Journals (Sweden)

    V. A. Solodkiy

    2016-01-01

    Full Text Available Studies salvage interstitial radiation therapy for recurrent prostate cancer, launched at the end of the XX century. In recent years, more and more attention is paid to high-dose-rate brachytherapy (HDR-BT as a method of treating local recurrence.The purpose of research – preliminary clinical results of salvage high-dose-rate brachytherapy applied in cases of suspected local recurrence or of residual tumour after radiotherapy.Preliminary findings indicate the possibility of using HDR-BT, achieving local tumor control with low genitourinary toxicity.

  14. Novel agents and regimens for acute myeloid leukemia: 2009 ASH annual meeting highlights

    Directory of Open Access Journals (Sweden)

    Zhu Xiongpeng

    2010-04-01

    Full Text Available Abstract Prognostic markers, such as NPM1, Flt3-ITD, and cytogenetic abnormalities have made it possible to formulate aggressive treatment plans for unfavorable acute myeloid leukemia (AML. However, the long-term survival of AML with unfavorable factors remains unsatisfactory. The latest data indicate that the standard dose of daunorubicin (DNR at 45 mg/m2 is inferior to high dose 90 mg/m2 for induction therapy. The rates of complete remission and overall survival are significantly better in the high dose induction regimen. New regimens exploring the new liposomal encapsulation of Ara-C and DNR as well as addition of gemtuzumab ozogamicin monoclonal antibody have been studied. New agents, including the nucleoside analogues (clofarabine, sapacitabine, elacytarabine, FLT3 inhibitor (sorafenib, farnesyl-transferase inhibitor (tipifarnib, histone deacetylase inhibitor (vorinostat, lenalidomide, as well as DNA methyltransferase inhibitors (decitabine, azacitidine, were recently reported for AML treatment in the 2009 ASH annual meeting. This review also summarizes the updates of the clinical trials on novel agents including voreloxin, AS1413, behenoylara-C, ARRY520, ribavirin, AZD1152, AZD6244, and terameprocol (EM-1421 from the 2009 ASH annual meeting.

  15. Artificial skin and patient simulator comprising the artificial skin

    NARCIS (Netherlands)

    2011-01-01

    The invention relates to an artificial skin (10, 12, 14), and relates to a patient simulator (100) comprising the artificial skin. The artificial skin is a layered structure comprising a translucent cover layer (20) configured for imitating human or animal skin, and comprising a light emitting layer

  16. Coated silicon comprising material for protection against environmental corrosion

    Science.gov (United States)

    Hazel, Brian Thomas (Inventor)

    2009-01-01

    In accordance with an embodiment of the invention, an article is disclosed. The article comprises a gas turbine engine component substrate comprising a silicon material; and an environmental barrier coating overlying the substrate, wherein the environmental barrier coating comprises cerium oxide, and the cerium oxide reduces formation of silicate glass on the substrate upon exposure to corrodant sulfates.

  17. High-dose cisplatin with dipyridamole in advanced non-small cell lung cancer. A Grupo Oncológico Cooperativo del Sur study.

    Science.gov (United States)

    Vallejo, C T; Rabinovich, M G; Perez, J E; Rodriguez, R; Machiavelli, M R; Leone, B A; Romero, A D; Lacava, J A; Cuevas, M A; Langhi, M J

    1995-06-01

    From March 1991 to October 1992, 41 patients with advanced non-small cell lung cancer (NSCLC) (20 stage IIIB and 21 stage IV) received a regimen consisting of cisplatin (CP) 100 mg/m2 i.v. days 1 and 8, and dipyridamole (DPD) 100 mg p.o. 75 minutes before CP, and then at hours 6, 12, and 18 as first-line chemotherapy. Cycles were repeated every 28 days for a total of 3. Median age was 56 years (range: 40-70). All patients had a performance status 0 to 1 and a weight loss < or = 10%. Squamous-cell carcinoma was diagnosed in 19 patients; adenocarcinoma in 16, and large-cell carcinoma in 6. A total of 37 patients were fully evaluable for response, whereas 39 were assessable for toxicity. No complete responses were observed: 5 patients (14%) achieved partial response; 23 patients (62%) showed no change, and progressive disease was observed in 9 (24%). The median time to treatment failure was 4 months, whereas median survival was 8 months. The average dose intensity received at the end of the third course of therapy was 46 mg/m2/week. There were no drug-related deaths. Toxicity was mild to moderate, with a high incidence of ototoxicity (54%) and emesis (67%). In conclusion, these results failed to demonstrate any significant advantage from a high-dose CP regimen modulated by DPD in patients with advanced NSCLC.

  18. High dose melphalan in the treatment of advanced neuroblastoma: results of a randomised trial (ENSG-1) by the European Neuroblastoma Study Group.

    Science.gov (United States)

    Pritchard, Jon; Cotterill, Simon J; Germond, Shirley M; Imeson, John; de Kraker, Jan; Jones, David R

    2005-04-01

    High dose myeloablative chemotherapy ("megatherapy"), with haematopoietic stem cell support, is now widely used to consolidate response to induction chemotherapy in patients with advanced neuroblastoma. In this study (European Neuroblastoma Study Group, ENSG1), the value of melphalan myeloablative "megatherapy" was evaluated in a randomised, multi-centre trial. Between 1982 and 1985, 167 children with stages IV and III neuroblastoma (123 stage IV > 1 year old at diagnosis and 44 stage III and stage IV from 6 to 12 months old at diagnosis) were treated with oncovin, cisplatin, epipodophyllotoxin, and cyclophosphamide (OPEC) induction chemotherapy every 3 weeks. After surgical excision of primary tumour, the 90 patients (69% of the total) who achieved complete response (CR) or good partial response (GPR) were eligible for randomisation either to high dose melphalan (180 mg per square meter) with autologous bone marrow support or to no further treatment. Sixty-five (72%) of eligible children were actually randomised and 21 of these patients were surviving at time of this analysis, with median follow-up from randomisation of 14.3 years. Five year event-free survival (EFS) was 38% (95% confidence interval (CI) 21-54%) in the melphalan-treated group and 27% (95% CI 12-42%) in the "no-melphalan" group. This difference was not statistically significant (P = 0.08, log rank test) but for the 48 randomised stage IV patients aged >1 year at diagnosis outcome was significantly better in the melphalan-treated group-5 year EFS 33% versus 17% (P = 0.01, log rank test). In this trial, high dose melphalan improved the length of EFS and overall survival of children with stage IV neuroblastoma >1 year of age who achieved CR or GPR after OPEC induction therapy and surgery. Multi-agent myeloablative regimens are now widely used as consolidation therapy for children with stage IV disease and in those with other disease stages when the MYCN gene copy number in tumour cells is amplified

  19. Successful Desensitization of T cell Flow Cytometry Crossmatch Positive Renal Transplant Recipients Using Plasmapheresis and Super High-Dose Intravenous Immunoglobulin

    Directory of Open Access Journals (Sweden)

    Yoichi Kakuta, MD, PhD

    2018-01-01

    Full Text Available Background. High-dose IVIG (2 g/kg alone or low-dose IVIG (100 mg/kg in conjunction with plasma exchange is typically administered as a renal transplantation desensitization therapy. Herein, we monitored changes in T cell and B cell flow cytometry crossmatch (FCXM to assess the effects of short-term super high-dose IVIG (4 g/kg administration with plasmapheresis before living-donor renal transplantation. Methods. Seventeen patients, each showing positive T cell FCXM (median ratio, ≥ 1.4 after 2 rounds of double-filtration plasmapheresis, received 4-day regimens of IVIG (1 g/kg per day over 1-week periods. T cell and B cell FCXM determinations were obtained after every IVIG dose and again up to 4 weeks after initiating IVIG to ascertain negative conversion of T cell FCXM (median ratio < 1.4. The primary study endpoint was the percentage of patients achieving T cell FCXM-negative status after the 4-dose IVIG regimen. Results. Upon completion (4 g/kg total or discontinuation of IVIG administration, 8 (47.1% of 17 patients displayed negative T cell FCXM. Based on Kaplan-Meier estimates, the cumulative T cell FCXM-negative conversion rate 4 weeks after IVIG administration initiation was 60.3%. The T cell FCXM-negative conversion rates after cumulative doses of 1, 2, 3, and 4 g/kg IVIG were 29.4%, 35.3%, 56.3%, and 46.7%, respectively. Conclusions. Desensitization of donor-specific antibody-positive renal transplant recipients seems achievable in only a subset of recipients through IVIG dosing (1 g/kg × 4 within 1 week after double-filtration plasmapheresis. The T cell FCXM-negative conversion rate resulting from a cumulative IVIG dose of 3 g/kg or greater surpassed that attained via conventional single-dose IVIG (2 g/kg protocol. This short-term high-dose IVIG desensitization protocol may be an alternative to conventional protocols for recipients with donor-specific antibody.

  20. Strategies to eradicate minimal residual disease in small cell lung cancer: high-dose chemotherapy with autologous bone marrow transplantation, matrix metalloproteinase inhibitors, and BEC2 plus BCG vaccination.

    Science.gov (United States)

    Krug, L M; Grant, S C; Miller, V A; Ng, K K; Kris, M G

    1999-10-01

    In the last 25 years, treatment for small cell lung cancer (SCLC) has improved with advances in chemotherapy and radiotherapy. Standard chemotherapy regimens can yield 80% to 90% response rates and some cures when combined with thoracic irradiation in limited-stage patients. Nonetheless, small cell lung cancer has a high relapse rate due to drug resistance; this has resulted in poor survival for most patients. Attacking this problem requires a unique approach to eliminate resistant disease remaining after induction therapy. This review will focus on three potential strategies: high-dose chemotherapy with autologous bone marrow transplantation, matrix metalloproteinase inhibitors, and BEC2 plus BCG vaccination.

  1. Efficacy of high-dose alkylating chemotherapy in HER2/neu-negative breast cancer

    NARCIS (Netherlands)

    Rodenhuis, S.; Bontenbal, M.; Hoesel, Q.G.C.M. van; Smit, W.M.; Nooij, M.A.; Voest, E.E.; Wall, E. van der; Hupperets, P.; Tinteren, H. van; Peterse, J.L.; Vijver, M.J. van de; Vries, E.G.E. de

    2006-01-01

    Background: High-dose chemotherapy in the adjuvant treatment of breast cancer has been abandoned by many. Patients and methods: 885 patients with stage III primary breast cancer and four or more axillary lymph node metastases were randomised to receive either five courses of FEC (fluorouracil,

  2. Efficacy of high-dose alkylating chemotherapy in HER2/neu-negative breast cancer

    NARCIS (Netherlands)

    Rodenhuis, S; Bontenbal, M; van Hoesel, QGCM; Smit, WM; Nooij, MA; Voest, EE; van der Wall, E; Hupperets, P; van Tinteren, H; Peterse, JL; van de Vijver, MJ; de Vries, EGE

    Background: High-dose chemotherapy in the adjuvant treatment of breast cancer has been abandoned by many. Patients and methods: 885 patients with stage III primary breast cancer and four or more axillary lymph node metastases were randomised to receive either five courses of FEC (fluorouracil,

  3. Daily high doses of fluoxetine for weight loss and improvement in lifestyle before bariatric surgery

    NARCIS (Netherlands)

    Dolfing, JG; Wolffenbuttel, BHR; Oei, HI; ten Hoor-Aukerna, NM; Schweitzer, DH

    Background: The number of gastric restrictive bariatric operations is increasing each year, but about one-fifth of patients will become disappointed due to unsatisfactory weight reduction or annoying complications. We questioned whether weight reduction by taking high doses of fluoxetine improves

  4. Fertility of Tall Girls Treated with High-Dose Estrogen, a Dose-Response Relationship

    NARCIS (Netherlands)

    Hendriks, A. E. J.; Drop, S. L. S.; Laven, J. S. E.; Boot, A. M.

    Context: High-dose estrogen treatment to reduce final height of tall girls increases their risk for infertility in later life. Objective: The aim was to study the effect of estrogen dose on fertility outcome of these women. Design/Setting: We conducted a retrospective cohort study of university

  5. Differential sensitivity of long-sleep and short-sleep mice to high doses of cocaine.

    Science.gov (United States)

    de Fiebre, C M; Ruth, J A; Collins, A C

    1989-12-01

    The cocaine sensitivity of male and female long-sleep (LS) and short-sleep (SS) mice, which have been selectively bred for differential ethanol-induced "sleep-time," was examined in a battery of behavioral and physiological tests. Differences between these two mouse lines were subtle and were seen primarily at high doses. At high doses, SS mice were more sensitive than LS mice, particularly to cocaine-induced hypothermia; however, significant hypothermia was not seen except at doses which were very near to the seizure threshold. During a 60-min test of locomotor activity, LS mice showed greater stimulation of Y-maze activity by 20 mg/kg cocaine than SS mice. Consistent with the finding of subtle differences in sensitivity to low doses of cocaine. LS and SS mice did not differ in sensitivity to cocaine inhibition of synaptosomal uptake of [3H]-dopamine, [3H]-norepinephrine or [3H]-5-hydroxytryptamine. However, consistent with the finding of differential sensitivity to high doses of cocaine, SS mice were more sensitive to the seizure-producing effects of the cocaine and lidocaine, a local anesthetic. It is hypothesized that the differential sensitivity of these mouse lines to high doses of cocaine is due to differential sensitivity to cocaine's actions on systems that regulate local anesthetic effects. Selective breeding for differential duration of alcohol-induced "sleep-time" may have resulted in differential ion channel structure or function in these mice.

  6. Perennial soybean seeds coated with high doses of boron and zinc ...

    African Journals Online (AJOL)

    The objective of this work was to study combinations of high doses of boron (B) and zinc (Zn) in the recoating of perennial soybean seeds, in order to provide these nutrients to the future plants. The physical, physiological and nutritional characteristics of the coated seeds and initial development of plants in a greenhouse ...

  7. Early Angiographic Resolution of Cerebral Vasospasm with High Dose Intravenous Milrinone Therapy

    Directory of Open Access Journals (Sweden)

    F. A. Zeiler

    2015-01-01

    Full Text Available Background. Treatment of symptomatic delayed cerebral ischemia (DCI after subarachnoid hemorrhage (SAH is difficult. Recent studies suggest intravenous (IV high dose milrinone as a potential therapy. The timing to angiographic response with this is unclear. Methods. We reviewed the chart of one patient admitted for SAH who developed symptomatic DCI and was treated with high dose IV milrinone. Results. A 66-year-old female was admitted with a Hunt and Hess clinical grade 4, World Federation of Neurological Surgeons (WFNS clinical grade 4, and SAH secondary to a left anterior choroidal artery aneurysm which was clipped. After bleed day 6, the patient developed symptomatic DCI. We planned for angioplasty of the proximal segments. We administered high dose IV milrinone bolus followed by continuous infusion which led to clinical improvement prior to angiography. The angiogram performed 1.5 hours after milrinone administration displayed resolution of the CT angiogram and MRI based cerebral vasospasm such that further intra-arterial therapy was aborted. She completed 6 days of continuous IV milrinone therapy, was transferred to the ward, and subsequently rehabilitated. Conclusions. High dose IV milrinone therapy for symptomatic DCI after SAH can lead to rapid neurological improvement with dramatic early angiographic improvement of cerebral vasospasm.

  8. Quantitative MR changes in Gd-DTPA enhancement after high dose intravenous methylprednisolone in multiple sclerosis

    International Nuclear Information System (INIS)

    Barkhof, F.; Valk, J.; Hommes, O.R.; Scheltens, P.

    1991-01-01

    The purpose of this study was to investigate the effect of high dose intravenous methylprednisolone (MP) on gadolinium-DTPA enhancement in MS-lesions. By means of this the influence of MP on the permeability of the blood-brain barrier can be studied. (author). 19 refs.; 1 fig

  9. Irreversible neurological worsening following high-dose corticosteroids in advanced progressive multiple sclerosis

    NARCIS (Netherlands)

    Koch, M; De Keyser, J

    2006-01-01

    Background: A course of high-dose corticosteroids has been shown to hasten recovery from a relapse of multiple sclerosis (MS). Some patients with progressive MS ask for a course with corticosteroids outside a relapse, hoping to gain some functional improvement. Objective: To describe 4 patients with

  10. Cytoprotective responses in HaCaT keratinocytes exposed to high doses of curcumin

    NARCIS (Netherlands)

    Lundvig, D.M.S.; Pennings, S.W.C.; Brouwer, K.M.; Mtaya-Mlangwa, M.; Mugonzibwa, E.; Kuijpers-Jagtman, A.M.; Wagener, F.A.D.T.G.; Hoff, J.W. Von den

    2015-01-01

    Wound healing is a complex process that involves the well-coordinated interactions of different cell types. Topical application of high doses of curcumin, a plant-derived polyphenol, enhances both normal and diabetic cutaneous wound healing in rodents. For optimal tissue repair interactions between

  11. Absorption of high-dose enteral vitamin A in lowbirth- weight neonates

    African Journals Online (AJOL)

    A randomised, double-blind placebo-controlled trial was designed to detennine whether high-dose (25 000 IU) enteral vitamin A. to correct deficiency, would be absorbed and well tolerated in low-birth-weight (LBW) neonates. Thirty-five LBW infants (950 - 1 700 g; gestational age 27 - 36 weeks) were allocated to receive ...

  12. Severe encephalopathy after high-dose chemotherapy with autologous stem cell support for brain tumours

    NARCIS (Netherlands)

    van den Berkmortel, F.; Gidding, C.; de Kanter, M.; Punt, C. J. A.

    2006-01-01

    Recurrent medulloblastoma carries a poor prognosis. Long-term survival has been obtained with high-dose chemotherapy with autologous stem cell transplantation and secondary irradiation. A 21-year-old woman with recurrent medulloblastoma after previous chemotherapy and radiotherapy is presented. The

  13. Surface damage of 316 stainless steel irradiated with 4He+ to high doses

    International Nuclear Information System (INIS)

    Kaminsky, M.; Das, S.K.

    1978-01-01

    Surface blistering of niobium by implantation with helium ions in the 9 to 15 keV range was investigated. The apparent disappearance of blisters at sufficiently high doses was believed to be an equilibrium effect. To determine whether high temperature annealing causes the equilibrium condition, stainless steel-316 samples were irradiated at a constant 450 0 C. Results are presented

  14. Clinical approaches involving thrombopoietin to shorten the period of thrombocytopenia after high-dose chemotherapy

    NARCIS (Netherlands)

    Tijssen, Marloes R.; van der Schoot, C. Ellen; Voermans, Carlijn; Zwaginga, Jaap Jan

    2006-01-01

    High-dose chemotherapy followed by a peripheral blood stem cell transplant is successfully used for a wide variety of malignancies. A major drawback, however, is the delay in platelet recovery. Several clinical strategies using thrombopoietin (Tpo) have been developed in an attempt to speed up

  15. High-dose chemotherapy : studies on supportive care, quality of life and late effects of treatment

    NARCIS (Netherlands)

    Nieboer, Peter

    2008-01-01

    Drug resistance is a major problem in the treatment of malignancies. Based on steep dose-response relationship for certain chemotherapeutic drugs in vitro on tumor cell survival, high-dose chemotherapy was considered of interest for the treatment of malignancies. Introduction of autologous

  16. Hemolytic uremic syndrome after high dose chemotherapy with autologous stem cell support

    NARCIS (Netherlands)

    van der Lelie, H.; Baars, J. W.; Rodenhuis, S.; Van Dijk, M. A.; de Glas-Vos, C. W.; Thomas, B. L.; van Oers, R. H.; von dem Borne, A. E.

    1995-01-01

    BACKGROUND: Chemotherapy intensification may lead to new forms of toxicity such as hemolytic uremic syndrome. METHODS: Three patients are described who developed this complication 4 to 6 months after high dose chemotherapy followed by autologous stem cell support. The literature on this subject is

  17. Perioperative Interstitial High-Dose-Rate Brachytherapy for the Treatment of Recurrent Keloids

    DEFF Research Database (Denmark)

    Jiang, Ping; Baumann, René; Dunst, Jürgen

    2016-01-01

    PURPOSE: To prospectively evaluate high-dose-rate brachytherapy in the treatment of therapy-resistant keloids and report first results, with emphasis on feasibility and early treatment outcome. METHODS AND MATERIALS: From 2009 to 2014, 24 patients with 32 recurrent keloids were treated with immed...

  18. Influence of high doses of manganese, copper, zinc and boron on some legumes

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, G

    1973-01-01

    Macroscopic and microscopic examinations showed the following symptoms of an excess in trace elements: (1) High doses of manganese (50-150 ppm) cause dark patches (chloroplast accumulation) in young leaves, and necrosis of the leaf margin (MnO/sub 2/ accumulation) in older leaves. The roots become brown and die off. Roots newly formed in compensation are strikingly light-colored. (2) High doses of copper (5-40 ppm) cause iron deficiency chlorosis. A large number of side roots develop in quick succession as a result of damage to the root apex, so that a thick tangle of roots is formed. (3) High doses of zinc (50-150 ppm) bring about dark green, very brittle young leaves with very high ZnO content. The older leaves become red and then yellow. The roots remain stunted because of inhibited growth in length. (4) High doses of boron (30-90 ppm) cause a leaf necrosis which proceeds in the sequence tip, margin, lamina. The roots are not affected in any characteristic way. They become brown and die off.

  19. Determination of air kerma standard of high dose rate 192Ir brachytherapy source

    International Nuclear Information System (INIS)

    Pires, E.J.; Alves, C.F.E.; Leite, S.P.; Magalhaes, L.A.G.; David, M.G.; Almeida, C.E. de

    2015-01-01

    This paper presents the methodology developed by the Laboratorio de Ciencias Radiologicas and presently in use for determining of the air kerma standard of 192 Ir high dose rate sources to calibrate well-type chambers. Uncertainty analysis involving the measurements procedure are presented. (author)

  20. Hemolytic anemia following high dose intravenous immunoglobulin in patients with chronic neurological disorders

    DEFF Research Database (Denmark)

    Markvardsen, Lars Høj; Christiansen, I; Harbo, Thomas

    2014-01-01

    High dose intravenous immunoglobulin (IVIG) is an established treatment for various neuromuscular disorders. Recently, cases of hemolytic anemia following IVIG have been observed. The objective of this study was to determine the extent of anemia and hemolysis after IVIG and its relationship...

  1. High-dose therapy followed by bone marrow transplantation for relapsed follicular non-Hodgkin's lymphoma

    NARCIS (Netherlands)

    Schouten, IC; Raemaekers, JJM; Kluin-Nelemans, HC; vanKamp, H; Mellink, WAM; vantVeer, MB

    1996-01-01

    Purpose: To analyze whether, in addition to survival, and disease-free survival progression-free interval after transplantation would be longer than the last progression-free interval before transplantation, supporting the argument that high-dose therapy may change the biologic behavior of the

  2. Maternal high-dose folic acid during pregnancy and asthma medication in the offspring

    NARCIS (Netherlands)

    Zetstra-van der Woude, Priscilla A.; De Walle, Hermien E. K.; Hoek, Annemieke; Bos, H. Jens; Boezen, H. Marike; Koppelman, Gerhard H.; de Jong-van den Berg, Lolkje T. W.; Scholtens, Salome

    2014-01-01

    Purpose Low-dose folic acid supplementation (0.5 mg) taken during pregnancy has been associated with an increased risk for childhood asthma. The effect of high-dose folic acid (5 mg) advised to women at risk for having a child with neural tube defect has not been assessed so far. Our aim was to

  3. Occlusion-amblyopia following high dose oral levodopa combined with part time patching

    OpenAIRE

    Mihir Kothari

    2014-01-01

    Part time occlusion therapy is not reported to cause occlusion (reverse) amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa.

  4. Occlusion-amblyopia following high dose oral levodopa combined with part time patching.

    Science.gov (United States)

    Kothari, Mihir

    2014-12-01

    Part time occlusion therapy is not reported to cause occlusion (reverse) amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa.

  5. Occlusion-amblyopia following high dose oral levodopa combined with part time patching

    Directory of Open Access Journals (Sweden)

    Mihir Kothari

    2014-01-01

    Full Text Available Part time occlusion therapy is not reported to cause occlusion (reverse amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa.

  6. High Dose Ascorbate Causes Both Genotoxic and Metabolic Stress in Glioma Cells

    Science.gov (United States)

    Castro, Maria Leticia; Carson, Georgia M.; McConnell, Melanie J.; Herst, Patries M.

    2017-01-01

    We have previously shown that exposure to high dose ascorbate causes double stranded breaks (DSBs) and a build-up in S-phase in glioblastoma (GBM) cell lines. Here we investigated whether or not this was due to genotoxic stress as well as metabolic stress generated by exposure to high dose ascorbate, radiation, ascorbate plus radiation and H2O2 in established and primary GBM cell lines. Genotoxic stress was measured as phosphorylation of the variant histone protein, H2AX, 8-oxo-7,8-dihydroguanine (8OH-dG) positive cells and cells with comet tails. Metabolic stress was measured as a decrease in NADH flux, mitochondrial membrane potential (by CMXRos), ATP levels (by ATP luminescence) and mitochondrial superoxide production (by mitoSOX). High dose ascorbate, ascorbate plus radiation, and H2O2 treatments induced both genotoxic and metabolic stress. Exposure to high dose ascorbate blocked DNA synthesis in both DNA damaged and undamaged cell of ascorbate sensitive GBM cell lines. H2O2 treatment blocked DNA synthesis in all cell lines with and without DNA damage. DNA synthesis arrest in cells with damaged DNA is likely due to both genotoxic and metabolic stress. However, arrest in DNA synthesis in cells with undamaged DNA is likely due to oxidative damage to components of the mitochondrial energy metabolism pathway. PMID:28737676

  7. Diagnosis of cerebral metastases by means of standard doses of Gadobutrol versus a high-dose protocol. Intraindividual evaluation of a phase-II high-dose study

    International Nuclear Information System (INIS)

    Vogl, T.J.; Friebe, C.E.; Balzer, T.; Mack, M.G.; Steiner, S.; Schedel, H.; Pegios, W.; Lanksch, W.; Banzer, D.; Felix, R.

    1995-01-01

    In a clinical phase-II study 20 patients who had been diagnosed as having brain metastases with CT or MRT were studied prospectively with Gadobutrol, a new nonionic, low osmolality contrast agent. Each patient received an initial injection of 0.1 mmol/kg body weight and an additional dose of 0.2 mmol/kg Gadobutrol 10 min later. Spinecho images were obtained before and after the two applications of Gadobutrol. Dynamic scanning (Turbo-FLASH) was performed for 3 min after each injection of the contrast agent. Both quantitative and qualitative data were intraindividually evaluated. The primary tumor was a bronchial carcinoma in 11 cases; in 9 other cases there were different primary tumors. Forty-eight hours after the use of Gadobutrol there were no adverse signs in the clinical examination, vital signs or blood and urine chemistry. Statistical analysis (Friedman test and Wilcoxon test) of the C/N ratios between tumor and white matter, percentage enhancement, and visual assessment rating revealed statistically significant superiority of high-dose Gadobutrol injection in comparison to the standard dose. The percentage enhancement increased on average from 104% after 0.1 mmol/kg to 162% after 0.3 mmol/kg Gadobutrol. Qualitative delineation and contrast of the lesions increased significantly. The use of high-dose Gadobutrol improved the detection of 36 additional lesions in 6 patients. (orig./VHE) [de

  8. Hypertonic saline solution and high-dose furosemide infusion in cardiorenal syndrome: our experience

    Directory of Open Access Journals (Sweden)

    Francesco Ventrella

    2013-03-01

    Full Text Available Introduction Heart failure is frequently complicated by renal failure, and this association is a negative prognostic factor. These patients sometimes present oligo-/anuria and resistance to high-dose furosemide, a condition referred to as the cardiorenal syndrome (CRS. Acute or chronic reductions in left ventricular function result in decreased blood flow, with reduction of renal perfusion and activation of several neurohormonal systems, which cause resistance to diuretic therapy. This condition often requires ultrafiltration, which is an effective, but invasive and expensive procedure. Infusions of hypertonic saline solution (HSS and high-dose furosemide can be an effective alternative. Materials and methods From November 2009 through May 2010, our team treated 20 patients with CRS and resistance to iv boluses of high-dose furosemide. These patients were treated with small-volume (150-250 mL infusions of HSS (NaCl 1.57 – 4.5%, depending on serum Na values and high-dose furosemide twice a day. The aim of this treatment is to modify renal hemodynamics and the water-saline balance in the kidney by counteracting the extracellular fluid accumulation and eliminating symptoms of congestion. Results In 18 patients (90%, urine output was restored and renal function improved during the first hours of treatment. Clinical improvement was evident from the first day of therapy, and there were no adverse events. Two patients (10% did not respond to the treatment: one (who had been in critical condition since admission died; the other required regular sessions of ultrafiltration. Conclusions HSS combined with high-dose furosemide is a safe, effective, low-cost approach to the treatment of CRS that is resistant to diuretic therapy.

  9. Review of high-dose intravenous vitamin C as an anticancer agent.

    Science.gov (United States)

    Wilson, Michelle K; Baguley, Bruce C; Wall, Clare; Jameson, Michael B; Findlay, Michael P

    2014-03-01

    In the 1970s, Pauling and Cameron reported increased survival of patients with advanced cancer treated with high-dose intravenous (IV) vitamin C (L-ascorbate, ascorbic acid). These studies were criticized for their retrospective nature and lack of standardization of key prognostic factors including performance status. Subsequently, several well-designed randomized controlled trials failed to demonstrate a significant survival benefit, although these trials used high-dose oral vitamin C. Marked differences are now recognized in the pharmacokinetics of vitamin C with oral and IV administration, opening the issue of therapeutic efficacy to question. In vitro evidence suggests that vitamin C functions at low concentrations as an antioxidant but may have pro-oxidant activity at high concentrations. The mechanism of its pro-oxidant action is not fully understood, and both intra- and extracellular mechanisms that generate hydrogen peroxide have been proposed. It remains to be proven whether vitamin C-induced reactive oxygen species occur in vivo and, if so, whether this will translate to a clinical benefit. Current clinical evidence for a therapeutic effect of high-dose IV vitamin C is ambiguous, being based on case series. The interpretation and validation of these studies is hindered by limited correlation of plasma vitamin C concentrations with response. The methodology exists to determine if there is a role for high-dose IV vitamin C in the treatment of cancer, but the limited understanding of its pharmacodynamic properties makes this challenging. Currently, the use of high-dose IV vitamin C cannot be recommended outside of a clinical trial. © 2014 Wiley Publishing Asia Pty Ltd.

  10. High Dose Oral Calcium Treatment in Patients with Vitamin D-dependent Rickets Type II

    Directory of Open Access Journals (Sweden)

    R Vakili

    2017-02-01

    Full Text Available BACKGROUND AND OBJECTIVE: Vitamin D-dependent rickets type II (VDDR2 is a rare genetic disorder caused by mutations in vitamin D receptor (VDR and leads to resistance to biological effects of calcitriol. Based on the type of mutation, this disease is resistant to calcitriol even at high doses of calcitriol and successful treatment of these patients requires hypocalcemic modification through administration of high doses of calcium and bypassing the intestinal defect in VDR signaling. In addition to the need for frequent hospitalization and high costs, intravenous administration of calcium is associated with complications and problems such as arrhythmia and sepsis, venous catheter infection and hypercalciuria. This study aims to report the positive treatment effects of high doses of oral calcium in 4 patients with vitamin D-dependent rickets type II. CASE REPORT: In this study, 4 patients with vitamin D-dependent rickets type II, diagnosed based on clinical and biochemical symptoms of rickets with alopecia, underwent therapy using high doses of oral calcium (300 mg/kg/day in pediatric endocrinology and metabolism center of Imam Reza hospital. After a short period, increased growth rate in height, strength and elasticity of muscles was observed in addition to biochemical improvements without serious side effects and even one patient started walking independently within the first week of therapy for the first time. Patients were regularly followed up in terms of height and weight, growth rate and biochemical factors including calcium, phosphorus and alkaline phosphatase every 3 months for one year. CONCLUSION: Regardless of the type of mutation in vitamin D receptor, it is suggested that a 3-6 months trial of high dose oral calcium be started in each patient with vitamin D-dependent rickets type II, particularly for patients whose disease was diagnosed at lower ages.

  11. Treatment of carcinoma of uterine cervix with high-dose-rate intracavitary irradiation using Ralstron

    International Nuclear Information System (INIS)

    Suh, C.O.; Kim, G.E.; Loh, J.J.K.

    1988-01-01

    From May 1979 through December 1981, a total of 530 patients with carcinoma of the uterine cervix were treated with radiation therapy with curative intent. Of the 530 patients, 365 were treated with a high-dose-rate remote-controlled afterloading system (RALS) using a cobalt source, and 165 patients received a low dose rate using a radium source. External pelvic irradiation with a total of 40-50 Gy to the whole pelvis followed by intracavitary radiation (ICR) with a total dose of 30-39 Gy in ten to 13 fractions to point A was the treatment protocol. ICR was given three times a week with a dose of 3 Gy per fraction. Five-year actuarial survival rate with high-dose-rate ICR by stage was as follows: stage I:82.7% (N = 19) stage II:69.6% (N = 184), and stage III:52.2% (N = 156). The above results were comparable with those with conventional low-dose-rate ICR treatment, and late complications were far less. The application of high-dose-rate ICR was technically simple and easily performed on an outpatient basis without anesthesia, and the patients tolerated it very well. Radiation exposure to personnel was virtually none as compared with that of low-dose-rate ICR. Within a given period of time, more patients can be treated with high-dose-rate ICR because of the short treatment time. The authors therefore conclude that high-dose-rate ICR is suitable for a cancer center where a large number of patients are to be treated

  12. High-dose anti-histamine use and risk factors in children with urticaria.

    Science.gov (United States)

    Uysal, Pınar; Avcil, Sibelnur; Erge, Duygu

    2016-12-01

    The drugs of choice in the treatment of urticaria in children are H1-antihistamines. The aim of the study was to evaluate children with urticaria and define risk factors for requirement of high-dose H1-antihistamines in children with urticaria. The medical data of children who were diagnosed as having urticaria admitted to our outpatient clinic between January 2014 and January 2016 were searched. The medical histories, concomitant atopic diseases, parental atopy histories, medications, treatment responses, blood eosinophil and basophil counts, and serum total IgE levels were recorded. In addition, the urticaria activity score for seven days, autoimmune antibody tests, and skin prick test results were evaluated in children with chronic urticaria. The numbers of the children with acute and chronic urticaria were 138 and 92, respectively. The age of the children with chronic urticaria was higher than that of those with acute urticaria (p0.05). There was a negative correlation between blood eosinophil count and the UAS7 score in children with chronic urticaria (r=-0.276, p=0.011). Chronic urticaria and requirement of high dose H1-antihistamines were significant in children aged ≥10 years (p<0.001, p=0.015). High UAS7 score (OR: 1.09; CI 95%: [1.03-1.15]) and basopenia (OR: 6.77; CI 95%: [2.01-22.75]) were associated with the requirement of high-dose H1-AH in children with chronic urticaria. The requirement of high-dose H1-antihistamines was higher with children's increasing age. Disease severity and basopenia were risk factors for the requirement of high-dose H1-antihistamines.

  13. Braquiterapia de alta taxa de dose no Brasil High-dose rate brachytherapy in Brazil

    Directory of Open Access Journals (Sweden)

    Sérgio Carlos Barros Esteves

    2004-10-01

    Full Text Available A braquiterapia de alta taxa de dose foi introduzida em nosso meio em janeiro de 1991. Desde então, houve uma mudança significativa na abordagem das neoplasias malignas em relação às vantagens do novo método, e também resolução da demanda reprimida de braquiterapia para as neoplasias ginecológicas. Nos primeiros dez anos de atividade, o Brasil tratou, em 31 serviços, 26.436 pacientes com braquiterapia, sendo mais de 50% das pacientes portadoras de neoplasias do colo uterino. Este estudo mostra o número e o perfil de pacientes tratados com esse método e a sua distribuição no território nacional, deixando explícito o benefício da braquiterapia de alta taxa de dose para o Brasil.High-dose rate brachytherapy was first introduced in Brazil in January 1991. Significant changes in the management of malignant neoplasms were observed since utilization of high-dose rate brachytherapy. The high number of gynecological patients awaiting for brachytherapy also decreased during this period. In the first ten years 26,436 patients were treated with high-dose rate brachytherapy. More than 50% of these patients presented neoplasms of the uterine cervix. In this study we present the number and profile of the patients treated with high-dose rate brachytherapy as well as the distribution of these patients in the Brazilian territory, proving the benefit of the use of high-dose rate brachytherapy in Brazil.

  14. Impact of therapeutic and high doses of florfenicol on kidney and liver functional indicators in goat

    Directory of Open Access Journals (Sweden)

    Jan Muhammad Shah

    2016-10-01

    Full Text Available Aim: The aim of this study was to evaluate the impact of therapeutic and high doses of florfenicol on kidney and liver functional indicators in goat species. Materials and Methods: Six mature, healthy goats (combine breed and sex with average weight 25 kg were selected for this study. The therapeutic (20 mg/kg b.w. and high doses (40 and 60 mg of florfenicol were administered for 3 days with 24 h interval. Blood samples were collected at 0, 24, 48, 72, 96, and 120 h following the each administered dose. Results: The results showed that the therapeutic dose of florfenicol produced nonsignificant effect on serum urea, creatinine, total protein (TP, alkaline phosphatase (ALP, gamma-glutamyl transferase (GGT and bilirubin on all timings, and increased (p<0.05 the serum glutamic oxaloacetic transaminase (SGOT and serum glutamate-pyruvate transaminase (SGPT levels for 48 h. Whereas the high doses of florfenicol (40 and 60 mg significantly altered the kidney and liver functional indicators in the blood. In contrast with control, the serum urea level was (p<0.01 increased at all timing points. Creatinine values were altered (p<0.01, <0.05 in increasing manner from 24 to 96 h. The high dose of 40 mg decreased the TP (p<0.05 for 72 h and 60 mg persisted same effect (p<0.01 up to 120 h. The indices of ALP, GGT, SGOT, and SGPT were raised (p<0.01, <0.05 at all timings. The bilirubin indexes also (p<0.05 elevated from 48 to 72. Conclusion: It was concluded that the high doses of florfenicol produced reversible dose-dependent effects on functional indicators of kidney and liver such as urea, creatinine, TP, ALP, SGOT, SGPT, GGT, and bilirubin.

  15. Prophylactic antibiotic regimens in tumour surgery (PARITY)

    DEFF Research Database (Denmark)

    Petersen, Michael Mørk; Hettwer, Werner H; Grum-Schwensen, Tomas

    2015-01-01

    -day regimen of post-operative antibiotics, in comparison to a 24-hour regimen, decreases surgical site infections in patients undergoing endoprosthetic reconstruction for lower extremity primary bone tumours. METHODS: We performed a pilot international multi-centre RCT. We used central randomisation...... to conceal treatment allocation and sham antibiotics to blind participants, surgeons, and data collectors. We determined feasibility by measuring patient enrolment, completeness of follow-up, and protocol deviations for the antibiotic regimens. RESULTS: We screened 96 patients and enrolled 60 participants......% at one year (the remainder with partial data or pending queries). In total, 18 participants missed at least one dose of antibiotics or placebo post-operatively, but 93% of all post-operative doses were administered per protocol. CONCLUSIONS: It is feasible to conduct a definitive multi-centre RCT of post...

  16. A phase II study of V-BEAM as conditioning regimen before second auto-SCT for multiple myeloma.

    Science.gov (United States)

    Wang, T-F; Fiala, M A; Cashen, A F; Uy, G L; Abboud, C N; Fletcher, T; Wu, N; Westervelt, P; DiPersio, J F; Stockerl-Goldstein, K E; Vij, R

    2014-11-01

    High-dose melphalan has been the standard conditioning regimen for auto-SCT in multiple myeloma (MM) for decades. A more effective conditioning regimen may induce deeper responses and longer remission duration. It is especially needed in the setting of second auto-SCT, which rarely achieves comparable results with the first auto-SCT using the same conditioning regimen. Here we conducted a phase II study to investigate the efficacy and safety of a conditioning regimen V-BEAM (bortezomib-BEAM) before second auto-SCT for multiple myeloma. Ten patients were enrolled from September 2012 to May 2013. The CR rate at day +100 after auto-SCT was 75%; all except for one patient remained in remission after a median follow-up of 6 months. Three patients developed Clostridium difficile infection. Two patients died within the first 30 days of auto-SCT from neutropenic colitis and overwhelming sepsis, respectively. Due to the high rate of morbidity and mortality, the study was terminated after 10 patients. In summary, although the conditioning regimen V-BEAM before second auto-SCT for MM provided promising responses, it was associated with unexpected treatment-related toxicity and should not be investigated further without modifications.

  17. High dose-rate brachytherapy for elderly patients with uterine cervical cancer

    International Nuclear Information System (INIS)

    Chen, Shang-Wen; Liang, Ji-An; Yang, Shih-Neng; Lin, Fang-Jen

    2003-01-01

    The need for radiotherapy (RT) in cancer treatment for the elderly patient is growing. The purpose of this study was to analyze the efficacy and complication rate for radiotherapy, using external-beam irradiation (EBRT) and high dose-rate intracavitary brachytherapy (HDRICB), for patients aged 70 years or older with carcinoma of the uterine cervix. From September 1992 to December 1997, 295 patients diagnosed with uterine cervical cancer completed RT at the Shin Kong Memorial Hospital and China Medical College Hospital. Two hundred and fifty-eight patients [International Federation of Gynecology and Obstetrics (FIGO) stage distribution: 35 Ib, 26 IIa, 122 IIb, 10 IIIa, 58 IIIb, 7 IVa] who had undergone at least two courses of HDRICB and a minimum of 3 years of follow-up, were evaluated. A retrospective analysis was conducted to compare the outcome of radiation therapy for the 179 patients under 70 years of age (younger group) and the 79 patients aged 70 years or older (older group). The RT consisted of EBRT followed by HDRICB. After a total EBRT dose of 40-45 Gy/20 in 25 fractions, irradiating the whole pelvis over 4-5 weeks, dosage for patients diagnosed as FIGO stage IIb-IVa bilateral parametrial disease was boosted to 54-58 Gy, with central shielding. HDRICB was administered at 1-week intervals using an Ir-192 remote after-loading technique. Ninety-nine patients (38.4%) received three fractions of HDRICB, while 156 patients (60.5%) had four fractions. Total prescribed Point A dosages (EBRT+HDRICB) ranged from 58 to 71.6 Gy (median, 65.6 Gy) for stage IB-IIA, while for larger lesions (stage IIB-IVA) analogous dosages were 59-75.6 Gy (median, 65.6 Gy). Median follow-up durations for the older and younger groups were 56/55 months, respectively. The respective 5-year actuarial survivals (AS) for the older and younger groups were 82/85% for stage Ib, 65/65% for IIa, 61/71% for IIb and 35/59% for IIIa-b. The 5-year cause-specific survivals (CSS) for the older and

  18. Compositions comprising enhanced graphene oxide structures and related methods

    Science.gov (United States)

    Kumar, Priyank Vijaya; Bardhan, Neelkanth M.; Belcher, Angela; Grossman, Jeffrey

    2016-12-27

    Embodiments described herein generally relate to compositions comprising a graphene oxide species. In some embodiments, the compositions advantageously have relatively high oxygen content, even after annealing.

  19. Comparison of two dose regimens of ibuprofen for the closure of patent ductus arteriosus in preterm newborns.

    Science.gov (United States)

    Dornelles, Laura Vargas; Corso, Andréa Lúcia; Silveira, Rita de Cássia; Procianoy, Renato Soibelmann

    2016-01-01

    To compare the efficacy of intravenous ibuprofen at high (20-10-10mg/kg/dose) and low doses (10-5-5mg/kg/dose) the closure of patent ductus arteriosus in preterm newborns. A cohort study with historical control of newborns that received high- and low-dose intravenous ibuprofen, from 2010 to 2013 in a neonatal intensive care unit, for closure of the patent ductus arteriosus, documented by echocardiography. Secondary outcomes included the number of ibuprofen cycles, incidence of bronchopulmonary dysplasia, necrotizing enterocolitis, changes in renal function, and death. Seventy-seven patients received three doses of ibuprofen for the treatment of patent ductus arteriosus, with 33 receiving high-dose and 44 low-dose therapy. The ductus closed after the first cycle in 25 (56.8%) low-dose patients and in 17 (51.5%) high-dose patients (p>0.99). Sixteen patients received a second cycle of ibuprofen, and the ductus closed in 50% after low-dose and in 60% after high-dose therapy (p>0.99). Seven patients required surgery for ductus closure, 13.6% in the low-dose group and 3% in the high-dose group (p=0.22). Thirty-nine patients developed bronchopulmonary dysplasia, 50% in the low-dose group and 51.5% in the high-dose group (p>0.99). Twenty-two (50%) low-dose patients died vs. 15 (45.5%) high-dose patients (p=0.86). There was no difference in closure of the ductus arteriosus or occurrence of adverse effects between the two dose regimens. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  20. Comparison of two dose regimens of ibuprofen for the closure of patent ductus arteriosus in preterm newborns,

    Directory of Open Access Journals (Sweden)

    Laura Vargas Dornelles

    2016-06-01

    Full Text Available Abstract Objective: To compare the efficacy of intravenous ibuprofen at high (20-10-10 mg/kg/dose and low doses (10-5-5 mg/kg/dose the closure of patent ductus arteriosus in preterm newborns. Methods: A cohort study with historical control of newborns that received high- and low-dose intravenous ibuprofen, from 2010 to 2013 in a neonatal intensive care unit, for closure of the patent ductus arteriosus, documented by echocardiography. Secondary outcomes included the number of ibuprofen cycles, incidence of bronchopulmonary dysplasia, necrotizing enterocolitis, changes in renal function, and death. Results: Seventy-seven patients received three doses of ibuprofen for the treatment of patent ductus arteriosus, with 33 receiving high-dose and 44 low-dose therapy. The ductus closed after the first cycle in 25 (56.8% low-dose patients and in 17 (51.5% high-dose patients (p > 0.99. Sixteen patients received a second cycle of ibuprofen, and the ductus closed in 50% after low-dose and in 60% after high-dose therapy (p > 0.99. Seven patients required surgery for ductus closure, 13.6% in the low-dose group and 3% in the high-dose group (p = 0.22. Thirty-nine patients developed bronchopulmonary dysplasia, 50% in the low-dose group and 51.5% in the high-dose group (p > 0.99. Twenty-two (50% low-dose patients died vs. 15 (45.5% high-dose patients (p = 0.86. Conclusions: There was no difference in closure of the ductus arteriosus or occurrence of adverse effects between the two dose regimens.

  1. Effectiveness of modified hyper-CVAD chemotherapy regimen in the treatment of adult acute lymphoblastic leukemia: a retrospective experience.

    Science.gov (United States)

    Jalaeikhoo, Hasan; Rajaeinejad, Mohsen; Keyhani, Manoutchehr; Zokaasadi, Mohammad; Dehghani Firoozabadi, Mohammad Mehdi

    2018-03-01

    Several chemotherapy regimens have been developed for the treatment of acute lymphoblastic leukemia (ALL), but relapse still presents the most common obstacles to attaining long-term survival. The hyper-CVAD (hyperfractionated cyclophosphamide, vincristine, doxorubicin, and prednisolone)/HD MTX and Ara-C (high-dose methotrexate and cytarabine) chemotherapy regimen was first started in the MD Anderson Cancer Center as an intensive regimen for adult patients with ALL. The purpose of this study was to evaluate the effectiveness of a modified hyper-CVAD protocol. We used hyper-CVAD as consolidation/maintenance after remission induction with daunorubicin, vincristine, and prednisolone (and cyclophosphamide for T-cell ALL only) rather than standard hyper-CVAD in order to reduce treatment complications. This study was conducted as a retrospective review of medical records of ALL patients at 501 army hospital, Tehran, Iran, from 2005 to 2015. Three hundred and one patients underwent modified hyper-CVAD chemotherapy regimen. Complete remission and overall survival (OS) rates were measured as primary endpoints. Two hundred and forty-six (81.7%) reached complete remission (CR) during the first 6 months of treatment, and 55 patients (18.3%) did not reach CR. The 5-year OS rate was 51.8% (95% CI (confidence interval): 45.1-57.8%). Modified hyper-CVAD regimen is an efficient intensive chemotherapy regimen for consolidation/maintenance of adults with newly diagnosed ALL and has an acceptable 5-year overall that is comparable to standard hyper-CVAD regimen. © 2018 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  2. Dramatic response to high-dose icotinib in a lung adenocarcinoma patient after erlotinib failure.

    Science.gov (United States)

    Guan, Yin; Zhao, Hong; Meng, Jing; Yan, Xiang; Jiao, ShunChang

    2014-02-01

    Epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor (TKI) retreatment is rarely administered for non-small cell lung cancer (NSCLC) patients who did not respond to previous TKI treatment. A high dose of TKI may overcome resistance to the standard dose of TKI and have different effectiveness toward cancer compared with the standard dose of TKI. This manuscript describes a dramatic and durable response to high-dose icotinib in a NSCLC patient who did not respond to a previous standard dose of erlotinib. The treatment extended the life of the patient for one additional year. A higher dose of icotinib deserves further study not only for patients whose therapy failed with the standard dose of TKI but also for newly diagnosed NSCLC patients with a sensitive mutation. Serial mutation testing during disease development is necessary for analysis and evaluation of EGFR TKI treatment. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Heavy ion time-of-flight ERDA of high dose metal implanted germanium

    Energy Technology Data Exchange (ETDEWEB)

    Dytlewski, N.; Evans, P.J.; Noorman, J.T. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Wielunski, L.S. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), Lindfield, NSW (Australia). Div. of Applied Physics; Bunder, J. [New South Wales Univ., Wollongong, NSW (Australia). Wollongong Univ. Coll

    1996-12-31

    With the thick Ge substrates used in ion implantation, RBS can have difficulty in resolving the mass-depth ambiguities when analysing materials composed of mixtures of elements with nearly equal masses. Additional, and complimentary techniques are thus required. This paper reports the use of heavy ion time-of-flight elastic recoil detection analysis (ToF- ERDA), and conventional RBS in the analysis of Ge(100) implanted with high dose Ti and Cu ions from a MEWA ion source . Heavy ion ToF ERDA has been used to resolve, and profile the implanted transition metal species, and also to study any oxygen incorporation into the sample resulting from the implantation, or subsequential reactions with air or moisture. This work is part of a study on high dose metal ion implantation of medium atomic weight semiconductor materials. 13 refs., 6 figs.

  4. Heavy ion time-of-flight ERDA of high dose metal implanted germanium

    Energy Technology Data Exchange (ETDEWEB)

    Dytlewski, N; Evans, P J; Noorman, J T [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Wielunski, L S [Commonwealth Scientific and Industrial Research Organisation (CSIRO), Lindfield, NSW (Australia). Div. of Applied Physics; Bunder, J [New South Wales Univ., Wollongong, NSW (Australia). Wollongong Univ. Coll

    1997-12-31

    With the thick Ge substrates used in ion implantation, RBS can have difficulty in resolving the mass-depth ambiguities when analysing materials composed of mixtures of elements with nearly equal masses. Additional, and complimentary techniques are thus required. This paper reports the use of heavy ion time-of-flight elastic recoil detection analysis (ToF- ERDA), and conventional RBS in the analysis of Ge(100) implanted with high dose Ti and Cu ions from a MEWA ion source . Heavy ion ToF ERDA has been used to resolve, and profile the implanted transition metal species, and also to study any oxygen incorporation into the sample resulting from the implantation, or subsequential reactions with air or moisture. This work is part of a study on high dose metal ion implantation of medium atomic weight semiconductor materials. 13 refs., 6 figs.

  5. High dose rate intracavitary afterloading irradiation in malignant inoperable obturation of bile ducts

    Energy Technology Data Exchange (ETDEWEB)

    Itami, J.; Saegusa, K.; Mamiya, T.; Miyoshi, T.; Arimizu, N.; Tsuchiya, Y.; Ohto, M.

    1986-02-01

    After decompression of the bile duct with PTCD, seven patients with carcinomas of the bile ducts were submitted to an intracavitary Ir-afterloading irradiation performed according to the high-dose-rate method with a Buchler device. Most of the patients were irradiated with 30 Gy in two fractions. Five patients were also exposed to percutaneous radiation with 40 to 50 Gy. Local control was achieved in six patients. One patient developed a locoregional recurrence which was possibly due to a so-called 'geographic miss'. In one patient a benign fibrotic stenosis of the bile duct was found at the site of most intensive irradiation. Intracavitary irradiation is very important in the treatment of malignant of bile ducts. However, there is an urgent need of research with regard to the combined method with percutaneous irradiation and to the optimum fractionation of intracavitary high dose rate irradiation.

  6. Evaluation of glasses containing cadmium for high dose dosimetry by the thermoluminescence technique

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Gabriel Soares Marchiori de; Ferreira, Pamela Zati; Cunha, Diego Merigue da; Dantas, Noelio Oliveira; Silva, Anielle C.A.; Perini, Ana Paula; Neves, Lucio Pereira, E-mail: lucio.neves@ufu.br [Universidade Federal de Uberlandia (INFIS/UFU), MG (Brazil). Instituto de Fisica; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil); Carrera, Betzabel Noemi Silva; Watanabe, Shigueo [Universidade de Sao Paulo (IF/USP), SP (Brazil). Instituto de Fisica

    2016-07-01

    New glass matrices were evaluated for high dose dosimetry by the thermoluminescence technique. Their nominal composition are 20Li{sub 2}CO{sub 3}.10Al{sub 2}O{sub 3}.15CdO.55B{sub 2}O{sub 3} and 20Li{sub 2}CO{sub 3}.10Al{sub 2}O{sub 3}.20CdO.50B{sub 2}O{sub 3} (mol%). The glass matrices were irradiated with different doses: 50, 100, 200, 500, 700 and 900 Gy, and the thermoluminescence emission curves were obtained for each of these values. The results show a great potential of using these matrices in high dose dosimetry. (author)

  7. Study of a new glass matrix by thermoluminescent technique for high-dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Pamela Z.; Carvalho, Gabriel S. Marchiori de; Cunha, Diego M. da; Dantas, Noelio O.; Silva, Anielle C.A.; Neves, Lucio P.; Perini, Ana P., E-mail: anapaula.perini@ufu.br [Universidade Federal de Uberlandia (UFU), MG (Brazil). Instituto de Fisica; Linda, V.E. Caldas [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Carrera, Betzabel N.S.; Watanabe, Shigueo [Universidade de Sao Paulo (IF/USP), Sao Paulo, SP (Brazil). Instituto de Fisica

    2016-07-01

    The thermoluminescence technique is widely used for both personal and for high-dose dosimetry. In this work, the thermoluminescence technique was utilized to study a new glass matrix, with nominal composition of 20Li{sub 2}CO{sub 3}.10Al{sub 2}O{sub 3}.30BaO.40B{sub 2}O{sub 3} (mol%), irradiated with different doses in a {sup 60}Co source. The glow curves and the dose-response curve were obtained for radiation doses of 10, 50, 100, 200 e 700 Gy. The results showed that this new glass matrix has potential use in high-dose dosimetry. (author)

  8. Practice for characterization and performance of a high-dose radiation dosimetry calibration laboratory

    International Nuclear Information System (INIS)

    2003-01-01

    This practice addresses the specific requirements for laboratories engaged in dosimetry calibrations involving ionizing radiation, namely, gamma-radiation, electron beams or X-radiation (bremsstrahlung) beams. It specifically describes the requirements for the characterization and performance criteria to be met by a high-dose radiation dosimetry calibration laboratory. The absorbed-dose range is typically between 10 and 10 5 Gy. This practice addresses criteria for laboratories seeking accreditation for performing high-dose dosimetry calibrations, and is a supplement to the general requirements described in ISO/IEC 17025. By meeting these criteria and those in ISO/IEC 17025, the laboratory may be accredited by a recognized accreditation organization. Adherence to these criteria will help to ensure high standards of performance and instill confidence regarding the competency of the accredited laboratory with respect to the services it offers

  9. Synergies Between ' and Cavity Formation in HT-9 Following High Dose Neutron Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Field, Kevin G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Parish, Chad M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Saleh, Tarik A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Eftink, Benjamin P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-06-01

    Candidate cladding materials for advanced nuclear power reactors including fast reactor designs require materials capable of withstanding high dose neutron irradiation at elevated temperatures. One candidate material, HT-9, through various research programs have demonstrated the ability to withstand significant swelling and other radiation-induced degradation mechanisms in the high dose regime (>50 displacements per atom, dpa) at elevated temperatures (>300 C). Here, high efficiency multi-dimensional scanning transmission electron microscopy (STEM) acquisition with the aid of a three-dimensional (3D) reconstruction and modeling technique is used to probe the microstructural features that contribute to the exceptional swelling resistance of HT-9. In particular, the synergies between ' and fine-scale and moderate-scale cavity formation is investigated.

  10. CT of multiple sclerosis: reassessment of delayed scanning with high doses of contrast material

    International Nuclear Information System (INIS)

    Spiegel, S.M.; Vinuela, F.; Fox, A.J.; Pelz, D.M.

    1985-01-01

    A prospective study involving 87 patients was carried out to evaluate the necessity for a high dose of contrast material in addition to delayed computed tomographic (CT) scanning for optimal detection of the lesions of multiple sclerosis in the brain. In patients with either clinically definite multiple sclerosis or laboratory-supported definite multiple sclerosis, CT scans were obtained with a uniform protocol. Lesions consistent with multiple sclerosis were demonstrated on the second scan in 54 patients. In 36 of these 54 patients, the high-dose delayed scan added information. These results are quite similar to those of a previous study from this institution using different patients, in whom the second scan was obtained immediately after the bolus injection of contrast material containing 40 g of organically bound iodine. The lack of real difference in the results of the two studies indicate that the increased dose, not just the delay in scanning, is necessary for a proper study

  11. Gene expression profiles following high-dose exposure to gamma radiation in salmonella enterica serovar typhimurium

    International Nuclear Information System (INIS)

    Lim, Sang Yong; Jung, Sun Wook; Joe, Min Ho; Kim, Dong Ho

    2008-01-01

    Microarrays can measure the expression of thousands of genes to identify the changes in expression between different biological states. To survey the change of whole Salmonella genes after a relatively high dose of gamma radiation (1 kGy), transcriptome dynamics were examined in the cells by using DNA microarrays. At least 75 genes were induced and 89 genes were reduced two-fold or more after irradiation. Several genes located in pSLT plasmid, cyo operon, and Gifsy prophage were induced along with many genes encoding uncharacterized proteins.While, the expression of genes involved in the virulence of Salmonella as well as metabolic functions were decreased. Although the radiation response as a whole could not be illustrated by using DNA microarrays, the data suggest that the response to high dose of irradiation might be more complex than the SOS response

  12. No seasonal accumulation of resistant P. falciparum when high-dose chloroquine is used

    DEFF Research Database (Denmark)

    Ursing, Johan; Kofoed, Poul-Erik; Rodrigues, Amabelia

    2009-01-01

    increase of pfcrt 76T if the high doses of CQ commonly used are effective. METHODS AND FINDINGS: P. falciparum parasite density, age, sex, the proportion of chloroquine resistance associated haplotypes pfcrt 76T and P. falciparum multidrug resistance gene 1 86Y were assessed in 988 samples collected from...... to become the dominant P.falciparum type in Guinea-Bissau. This is most likely due to the efficacy of high-dose chloroquine as used in Guinea-Bissau, combined with a loss of fitness associated with pfcrt 76T.......BACKGROUND: Potentially chloroquine resistant P. falciparum, identified by the 76T haplotype in the chloroquine resistance transporter (pfcrt 76T), are highly prevalent throughout Africa. In Guinea-Bissau, normal and double dose chloroquine have respective efficacies of 34% and 78% against P...

  13. The radiosensitizing effect of doranidazole on human colorectal cancer cells exposed to high doses of irradiation

    International Nuclear Information System (INIS)

    Zhang, Li; Gong, Aimin; Ji, Jun; Wu, Yuanyuan; Zhu, Xiaoyu; Lv, Suqing; Lv, Hongzhu; Sun, Xizhuo

    2007-01-01

    This paper investigates the effects of a new radiosensitizer, doranidazole, and enhancing irradiation on colorectal cancer cells. The radiosensitizing effect of doranidazole was determined using colony formation and propidium iodide (PI) assays to measure cell growth inhibition and the cell killing effect of human colorectal cancer cell lines exposed to high doses of γ-ray irradiation under hypoxic conditions in vitro. Fluorescence staining and cell migration assays were also used to assess the radiosensitizing effect. Cell proliferation evaluated by clonogenic survival curves was significantly inhibited by 5 mmol/L doranidazole, particularly at doses ranging from 10 to 30 Gy of irradiation. The radiosensitizing effect of doranidazole on colorectal cancer cells occurs in a time- and dose-dependent manner. Doranidazole also inhibited the mobility of cell invasion and migration. Doranidazole can enhance the killing effect and the cell growth inhibition of colorectal cancer after high-dose irradiation in a time and dose-dependent manner

  14. Gene expression profiles following high-dose exposure to gamma radiation in salmonella enterica serovar typhimurium

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Yong; Jung, Sun Wook; Joe, Min Ho; Kim, Dong Ho [Radiation Research Division for Biotechnology, Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of)

    2008-08-15

    Microarrays can measure the expression of thousands of genes to identify the changes in expression between different biological states. To survey the change of whole Salmonella genes after a relatively high dose of gamma radiation (1 kGy), transcriptome dynamics were examined in the cells by using DNA microarrays. At least 75 genes were induced and 89 genes were reduced two-fold or more after irradiation. Several genes located in pSLT plasmid, cyo operon, and Gifsy prophage were induced along with many genes encoding uncharacterized proteins.While, the expression of genes involved in the virulence of Salmonella as well as metabolic functions were decreased. Although the radiation response as a whole could not be illustrated by using DNA microarrays, the data suggest that the response to high dose of irradiation might be more complex than the SOS response.

  15. High-dose therapy improved the bone remodelling compartment canopy and bone formation in multiple myeloma

    DEFF Research Database (Denmark)

    Hinge, Maja; Delaissé, Jean-Marie; Plesner, Torben

    2015-01-01

    transplantation, and from 20 control patients with monoclonal gammopathy of undetermined significance were histomorphometrically investigated. This investigation confirmed that MM patients exhibited uncoupled bone formation to resorption and reduced canopy coverage. More importantly, this study revealed......Bone loss in multiple myeloma (MM) is caused by an uncoupling of bone formation to resorption trigged by malignant plasma cells. Increasing evidence indicates that the bone remodelling compartment (BRC) canopy, which normally covers the remodelling sites, is important for coupled bone remodelling....... Loss of this canopy has been associated with bone loss. This study addresses whether the bone remodelling in MM is improved by high-dose therapy. Bone marrow biopsies obtained from 20 MM patients, before and after first-line treatment with high-dose melphalan followed by autologous stem cell...

  16. Zinc comprising coordination compounds as growth stimulants of cotton seeds

    International Nuclear Information System (INIS)

    Yusupov, Z.N.; Nurmatov, T.M.; Rakhimova, M.M.; Dzhafarov, M.I.; Nikolaeva, T.B.

    1991-01-01

    Present article is devoted to zinc comprising coordination compounds as growth stimulants of cotton seeds. The influence of zinc coordination compounds with physiologically active ligands on germinative energy and seed germination of cotton was studied. The biogical activity and effectiveness of zinc comprising coordination compounds at application them for humidification of cotton seeds was studied as well.

  17. Electrochemical energy storage devices comprising self-compensating polymers

    Science.gov (United States)

    Johnson, Paul; Bautista-Martinez, Jose Antonio; Friesen, Cody; Switzer, Elise

    2018-01-30

    The disclosed technology relates generally to devices comprising conductive polymers and more particularly to electrochemical devices comprising self-compensating conductive polymers. In one aspect, electrochemical energy storage device comprises a negative electrode comprising an active material including a redox-active polymer. The device additionally comprises a positive electrode comprising an active material including a redox-active polymer. The device further comprises an electrolyte material interposed between the negative electrode and positive electrode and configured to conduct mobile counterions therethrough between the negative electrode and positive electrode. At least one of the negative electrode redox-active polymer and the positive electrode redox-active polymer comprises a zwitterionic polymer unit configured to reversibly switch between a zwitterionic state in which the zwitterionic polymer unit has first and second charge centers having opposite charge states that compensate each other, and a non-zwitterionic state in which the zwitterionic polymer unit has one of the first and second charge centers whose charge state is compensated by mobile counterions.

  18. Printhead and inkjet printer comprising such a printhead

    NARCIS (Netherlands)

    2007-01-01

    The invention relates to a printhead comprising multiple substantially closed ink chambers (13), the ink chambers being mutually separated by at least one wall (12), wherein each of the chambers comprises an electro-mechanical converter (15), where actuation of the converter leads to a volume change

  19. A photocurrent compensation method of bipolar transistors under high dose rate radiation and its experimental research

    International Nuclear Information System (INIS)

    Yin Xuesong; Liu Zhongli; Li Chunji; Yu Fang

    2005-01-01

    Experiment using discrete bipolar transistors has been performed to verify the effect of the photocurrent compensation method. The theory of the dose rate effects of bipolar transistors and the photocurrent compensation method are introduced. The comparison between the response of hardened and unhardened circuits under high dose rate radiation is discussed. The experimental results show instructiveness to the hardness of bipolar integrated circuits under transient radiation. (authors)

  20. High dose radiation damage in nuclear energy structural materials investigated by heavy ion irradiation simulation

    International Nuclear Information System (INIS)

    Zheng Yongnan; Xu Yongjun; Yuan Daqing

    2014-01-01

    Structural materials in ITER, ADS and fast reactor suffer high dose irradiations of neutrons and/or protons, that leads to severe displacement damage up to lOO dpa per year. Investigation of radiation damage induced by such a high dose irradiation has attracted great attention along with the development of nuclear energy facilities of new generation. However, it is deeply hampered for the lacking of high dose neutron and proton sources. Irradiation simulation of heavy ions produced by accelerators opens up an effective way for laboratory investigation of high dose irradiation induced radiation damage encountered in the ITER, ADS, etc. Radiation damage is caused mainly by atomic displacement in materials. The displacement rate of heavy ions is about lO 3 ∼10 7 orders higher than those of neutrons and protons. High displacement rate of heavy ions significantly reduces the irradiation time. The heavy ion irradiation simulation technique (HIIS) technique has been developed at China Institute of Atomic Energy and a series of the HIIS experiments have been performed to investigate radiation damage in stainless steels, tungsten and tantalum at irradiation temperatures from room temperature to 800 ℃ and in the irradiation dose region up to 100 dpa. The experimental results show that he radiation swelling peak for the modified stainless steel appears in the temperature region around 580 ℃ and the radiation damage is more sensitive to the temperature, the size of the radiation induced vacancy cluster or void increase with the increasing of the irradiation dose, and among the three materials the home-made modified stainless steel has the best radiation resistant property. (authors)

  1. Persistent DNA damage after high dose in vivo gamma exposure of minipig skin.

    Directory of Open Access Journals (Sweden)

    Emad A Ahmed

    Full Text Available Exposure to high doses of ionizing radiation (IR can lead to localized radiation injury of the skin and exposed cells suffer dsDNA breaks that may elicit cell death or stochastic changes. Little is known about the DNA damage response after high-dose exposure of the skin. Here, we investigate the cellular and DNA damage response in acutely irradiated minipig skin.IR-induced DNA damage, repair and cellular survival were studied in 15 cm(2 of minipig skin exposed in vivo to ~50 Co-60 γ rays. Skin biopsies of control and 4 h up to 96 days post exposure were investigated for radiation-induced foci (RIF formation using γ-H2AX, 53BP1, and active ATM-p immunofluorescence. High-dose IR induced massive γ-H2AX phosphorylation and high 53BP1 RIF numbers 4 h, 20 h after IR. As time progressed RIF numbers dropped to a low of 3-fold elevated at all subsequent time points. Replicating basal cells (Ki67+ were reduced 3 days post IR followed by increased proliferation and recovery of epidermal cellularity after 28 days.Acute high dose irradiation of minipig epidermis impaired stem cell replication and induced elevated apoptosis from 3 days onward. DNA repair cleared the high numbers of DBSs in skin cells, while RIFs that persisted in <1% cells marked complex and potentially lethal DNA damage up to several weeks after exposure. An elevated frequency of keratinocytes with persistent RIFs may thus serve as indicator of previous acute radiation exposure, which may be useful in the follow up of nuclear or radiological accident scenarios.

  2. High-Dose Mannose-Binding Lectin Therapy for Ebola Virus Infection

    Science.gov (United States)

    2010-06-01

    host defense against a wide range of viral and other pathogens. MBL is a C-type lectin that recognizes hexose sugars including man- nose, glucose...should be evaluatedmore broadly as an immunotherapeutic agent for a wide spectrum of glycosylated pathogens. MATERIALS AND METHODS Production and... coagulation mod- ulators, antisense technologies, therapeutic antibodies and Table 1. Pharmacokinetic Parameters of Low- vs High-Dose Recombinant Human

  3. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    International Nuclear Information System (INIS)

    Chen, Y.; Yan, X.K.; Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K.

    2011-01-01

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of 60 Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of 60 Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0 -3 D 2 . Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy γ-irradiation from a supra-high dose 60 Co gamma-ray accident.

  4. Quality control of 192Ir high dose rate after loading brachytherapy dose veracity

    International Nuclear Information System (INIS)

    Feng Zhongsu; Xu Xiao; Liu Fen

    2008-01-01

    Recently, 192 Ir high dose rate (HDR) afterloading are widely used in brachytherapy. The advantage of using HDR systems over low dose rate systems are shorter treatment time and higher fraction dose. To guarantee the veracity of the delivery dose, several quality control methods are deseribed in this work. With these we can improve the position precision, time precision and dose precision of the brachytherapy. (authors)

  5. Rapid Onset of Retinal Toxicity From High-Dose Hydroxychloroquine Given for Cancer Therapy.

    Science.gov (United States)

    Leung, Loh-Shan B; Neal, Joel W; Wakelee, Heather A; Sequist, Lecia V; Marmor, Michael F

    2015-10-01

    To report rapid onset of retinal toxicity in a series of patients followed on high-dose (1000 mg daily) hydroxychloroquine during an oncologic clinical trial studying hydroxychloroquine with erlotinib for non-small cell lung cancer. Retrospective observational case series. Ophthalmic surveillance was performed on patients in a multicenter clinical trial testing high-dose (1000 mg daily) hydroxychloroquine for advanced non-small cell lung cancer. The US Food & Drug Administration-recommended screening protocol included only visual acuity testing, dilated fundus examination, Amsler grid testing, and color vision testing. In patients seen at Stanford, additional sensitive screening procedures were added at the discretion of the retinal physician: high-resolution spectral-domain optical coherence tomography (OCT), fundus autofluorescence (FAF) imaging, Humphrey visual field (HVF) testing, and multifocal electroretinography (mfERG). Out of the 7 patients having exposure of at least 6 months, 2 developed retinal toxicity (at 11 and 17 months of exposure). Damage was identified by OCT imaging, mfERG testing, and, in 1 case, visual field testing. Fundus autofluorescence imaging remained normal. Neither patient had symptomatic visual acuity loss. These cases show that high doses of hydroxychloroquine can initiate the development of retinal toxicity within 1-2 years. Although synergy with erlotinib is theoretically possible, there are no prior reports of erlotinib-associated retinal toxicity despite over a decade of use in oncology. These results also suggest that sensitive retinal screening tests should be added to ongoing and future clinical trials involving high-dose hydroxychloroquine to improve safety monitoring and preservation of vision. Published by Elsevier Inc.

  6. Controversies in external beam and high dose rate brachytherapy of oesophageal cancer

    International Nuclear Information System (INIS)

    Sur, R.K.; Levin, V.C.; Malas, Simon; Donde, Bernard

    1994-01-01

    Various controversies in the treatment of oesophageal carcinoma with external beam radiotherapy and high dose rate intracavitary irradiation have been reviewed. Conflicting results from different parts of the world has made it difficult to optimize the radiation dose that may give the best results. More studies and longer follow-up are needed before a definite conclusion can be made on the optimization of dose. (author). 18 refs., 2 tabs

  7. Non-linear failure analysis of HCPB blanket for DEMO taking into account high dose irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Aktaa, J., E-mail: jarir.aktaa@kit.edu [Karlsruhe Institute of Technology (KIT), Institute for Applied Materials, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Kecskés, S.; Pereslavtsev, P.; Fischer, U.; Boccaccini, L.V. [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2014-10-15

    Highlights: • First non-linear structural analysis for the European Helium Cooled Pebble Bed Blanket Module taking into account high dose irradiation. • Most critical areas were identified and analyzed with regard to the effect of irradiation on predicted damage at these areas. • Despite the extensive computing time 100 cycles were simulated by using the sub-modelling technique investigating damage at most critical area. • The results show a positive effect of irradiation on calculated damage which is mainly attributed to the irradiation induced hardening. - Abstract: For the European helium cooled pebble bed (HCPB) blanket of DEMO the reduced activation ferritic martensitic steel EUROFER has been selected as structural material. During operation the HCPB blanket will be subjected to complex thermo-mechanical loadings and high irradiation doses. Taking into account the material and structural behaviour under these conditions is a precondition for a reliable blanket design. For considering high dose irradiation in structural analysis of the DEMO blanket, the coupled deformation damage model, extended recently taking into account the influence of high dose irradiation on the material behaviour of EUROFER and implemented in the finite element code ABAQUS, has been used. Non-linear finite element (FE) simulations of the DEMO HCPB blanket have been performed considering the design of the HCPB Test Blanket Module (TBM) as reference and the thermal and mechanical boundary conditions of previous analyses. The irradiation dose rate required at each position in the structure as an additional loading parameter is estimated by extrapolating the results available for the TBM in ITER scaling the value calculated in neutronics and activation analysis for ITER boundary conditions to the DEMO boundary conditions. The results of the FE simulations are evaluated considering damage at most critical highly loaded areas of the structure and discussed with regard to the impact of

  8. Charge collection efficiency in ionization chambers exposed to electron beams with high dose per pulse

    Energy Technology Data Exchange (ETDEWEB)

    Laitano, R F [Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, ENEA Centro Ricerche Casaccia, c.p. 2400 Rome (Italy); Guerra, A S [Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, ENEA Centro Ricerche Casaccia, c.p. 2400 Rome (Italy); Pimpinella, M [Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, ENEA Centro Ricerche Casaccia, c.p. 2400 Rome (Italy); Caporali, C [Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, ENEA Centro Ricerche Casaccia, c.p. 2400 Rome (Italy); Petrucci, A [A.C.O. S. Filippo Neri, U.O. Fisica Sanitaria, Rome (Italy)

    2006-12-21

    The correction for charge recombination was determined for different plane-parallel ionization chambers exposed to clinical electron beams with low and high dose per pulse, respectively. The electron energy was nearly the same (about 7 and 9 MeV) for any of the beams used. Boag's two-voltage analysis (TVA) was used to determine the correction for ion losses, k{sub s}, relevant to each chamber considered. The presence of free electrons in the air of the chamber cavity was accounted for in determining k{sub s} by TVA. The determination of k{sub s} was made on the basis of the models for ion recombination proposed in past years by Boag, Hochhaeuser and Balk to account for the presence of free electrons. The absorbed dose measurements in both low-dose-per-pulse (less than 0.3 mGy per pulse) and high-dose-per-pulse (20-120 mGy per pulse range) electron beams were compared with ferrous sulphate chemical dosimetry, a method independent of the dose per pulse. The results of the comparison support the conclusion that one of the models is more adequate to correct for ion recombination, even in high-dose-per-pulse conditions, provided that the fraction of free electrons is properly assessed. In this respect the drift velocity and the time constant for attachment of electrons in the air of the chamber cavity are rather critical parameters because of their dependence on chamber dimensions and operational conditions. Finally, a determination of the factor k{sub s} was also made by zero extrapolation of the 1/Q versus 1/V saturation curves, leading to the conclusion that this method does not provide consistent results in high-dose-per-pulse beams.

  9. Radiation proctitis after the high dose rate brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Kitano, Masashi; Katsumata, Tomoe; Satoh, Takefumi

    2006-01-01

    We reviewed the medical records of 12 patients treated for rectal bleeding after high-dose rate brachytherapy for prostate cancer. All patients developed grade 2 proctitis according to the Common Terminology Criteria for Adverse Events (CTCAC) and no patients needed blood transfusion. The patients were treated with argon plasma coagulation (APC) and/or steroid suppositories. The bleeding stopped or improved in 11 patients. Although re-bleeding was noticed in 7 patients the same treatment was effective in 5 patients. (author)

  10. Non-linear failure analysis of HCPB blanket for DEMO taking into account high dose irradiation

    International Nuclear Information System (INIS)

    Aktaa, J.; Kecskés, S.; Pereslavtsev, P.; Fischer, U.; Boccaccini, L.V.

    2014-01-01

    Highlights: • First non-linear structural analysis for the European Helium Cooled Pebble Bed Blanket Module taking into account high dose irradiation. • Most critical areas were identified and analyzed with regard to the effect of irradiation on predicted damage at these areas. • Despite the extensive computing time 100 cycles were simulated by using the sub-modelling technique investigating damage at most critical area. • The results show a positive effect of irradiation on calculated damage which is mainly attributed to the irradiation induced hardening. - Abstract: For the European helium cooled pebble bed (HCPB) blanket of DEMO the reduced activation ferritic martensitic steel EUROFER has been selected as structural material. During operation the HCPB blanket will be subjected to complex thermo-mechanical loadings and high irradiation doses. Taking into account the material and structural behaviour under these conditions is a precondition for a reliable blanket design. For considering high dose irradiation in structural analysis of the DEMO blanket, the coupled deformation damage model, extended recently taking into account the influence of high dose irradiation on the material behaviour of EUROFER and implemented in the finite element code ABAQUS, has been used. Non-linear finite element (FE) simulations of the DEMO HCPB blanket have been performed considering the design of the HCPB Test Blanket Module (TBM) as reference and the thermal and mechanical boundary conditions of previous analyses. The irradiation dose rate required at each position in the structure as an additional loading parameter is estimated by extrapolating the results available for the TBM in ITER scaling the value calculated in neutronics and activation analysis for ITER boundary conditions to the DEMO boundary conditions. The results of the FE simulations are evaluated considering damage at most critical highly loaded areas of the structure and discussed with regard to the impact of

  11. Influence of high dose irradiation on core structural and fuel materials in advanced reactors

    International Nuclear Information System (INIS)

    1998-08-01

    The IAEA International Working Group on Fast Reactors (IWGFR) periodically organizes meeting to discuss and review important aspects of fast reactor technology. The fifth meeting held in Obninsk, Russian Federation, 16-19 June 1997, was devoted to the influence of high dose irradiation on the mechanical properties of reactor core structural and fuel materials. The proceedings includes the papers submitted at this meeting each with a separate abstract

  12. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, Antonio Cassio Assis, E-mail: acapellizzon@hcancer.org.br [A.C. Camargo Cancer Center, Sao Paulo, SP (Brazil). Departamento de Radioterapia

    2016-05-15

    For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy. (author)

  13. Management of hilar bile duct carcinoma with high-dose radiotherapy and expandable metallic stent placement

    International Nuclear Information System (INIS)

    Saito, Hiroya; Takamura, Akio

    2000-01-01

    This article describes our experience with high-dose radiotherapy in combination with the placement of expandable metallic stents (EMS) in the management of hilar bile duct carcinoma. Between 1988 and 1999, 107 consecutive patients with hilar bile duct carcinoma were treated with EMS placement either alone or in combination with high-dose radiotherapy. External beam radiotherapy (EBRT) was indicated in 101 patients, and in 86 this was combined with intraluminal 192 Ir irradiation (ILRT, 59-98 Gy) EMS were placed after the completion of radiotherapy. The 1-, 2-, 3-, and 5-year actuarial survival rates for the radiotherapy group were 66.4%, 23.4%, 15.6%, 7.8%, respectively, and the 1- and 2-year actuarial survival rates for the nonradiotherapy group were 66.4% and 0%, respectively. The placement of EMS was useful for the early establishment of an internal bile passage in radically irradiated patients and the 1-, 2-, 3-, and 5-year actuarial patency rates for the radiotherapy group were 56.3%, 45.3%, 35.2%, and 23.4%, respectively, and the 1- and 2-year actuarial patency rates for the non radiotherapy group were 50.0% and 0% respectively. High-dose radiotherapy, consisting of ILRT and EBRT, appears to be feasible in the management of hilar bile duct carcinoma, and it offers a survival advantage for patients no suited for surgical resection. The placement of EMS assists the internal bile flow and lengthens survival after high-dose radiotherapy. (author)

  14. Epithelial regeneration of transposed intestine after high doses of X irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Both, N.J. de; Vermey, M [Erasmus Universiteit, Rotterdam (Netherlands)

    1976-01-01

    The regeneration capacities of normal and transposed small bowel epithelium were compared in rats after applying high doses of x irradiation. It has been shown that the potency of the mucosa to regenerate was much higher than assumed and that the mucosa could regenerate after single doses varying from 2000 to 5000 R. Even in the villus epithelium and in flat epithelium covering infiltrates of the lamina propria cells survived, which were still able to resume proliferative activity several days after irradiation.

  15. Polybutadiene and Styrene-Butadiene rubbers for high-dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Lucas N. [Instituto Federal de Educacao, Ciencia e Tecnologia de Goias-IFG,Campus Goiania, Goiania -GO (Brazil); Instituto de Pesquisas Energeticas e Nucleares -IPEN, Sao Paulo-SP (Brazil); Vieira, Silvio L. [Instituto de Fisica, Universidade Federal de Goias-UFG, Campus Samambaia, Goiania-GO (Brazil); Schimidt, Fernando [Instituto Federal de Educacao, Ciencia e Tecnologia de Goias-IFG,Campus Inhumas, Inhumas-GO (Brazil); Antonio, Patricia L.; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares -IPEN, Sao Paulo-SP (Brazil)

    2015-07-01

    Polybutadiene and Styrene-Butadiene are synthetical rubbers used widely for pneumatic tires manufacturing. In this research, the dosimeter characteristics of those rubbers were studied for application in high-dose dosimetry. The rubber samples were irradiated with doses of 10 Gy up to 10 kGy, using a {sup 60}Co Gamma Cell-220 system (dose rate of 1.089 kGy/h) and their readings were taken on a Fourier Transform Infrared Spectroscopy-FTIR system (model Frontier/Perkin Elmer). The ratios of two absorbance peaks were taken for each kind of rubber spectrum, Polybutadiene (1306/1130 cm{sup -1}) and Styrene-Butadiene (1449/1306 cm{sup -1}). The ratio calculated was used as the response to the irradiation, and is not uniform across the sample. From the results, it can be concluded for both rubbers: a) the dose-response curves may be useful for high-dose dosimetry (greater than 250 Gy); b) their response for reproducibility presented standard deviations lower than 2.5%; c) the relative sensitivity was higher for Styrene-Butadiene (1.86 kGy{sup -1}) than for Polybutadiene (1.81 kGy{sup -1}), d) for doses of 10 kGy to 200 kGy, there was no variation in the dosimetric response. Both types of rubber samples showed usefulness as high-dose dosimeters. (authors)

  16. Cosmetic results in early stage breast cancer patients with high-dose brachytherapy after conservative surgery

    International Nuclear Information System (INIS)

    Torres, Felipe; Pineda, Beatriz E

    2004-01-01

    Purpose: to reveal cosmetic results in patients at early stages of low risk breast cancer treated with partial accelerated radiotherapy using high dose rate brachytherapy. Methods and materials: from March 2001 to July 2003,14 stages l and ll breast cancer patients were treated at the Colombian national cancer institute in Bogota with conservative surgery and radiotherapy upon the tumor bed (partial accelerated radiotherapy), using interstitial implants with iridium 192 (high dose rate brachytherapy) with a dose of 32 Gys, over 4 days, at 8 fractions twice a day. Results: with an average follow up of 17.7 months, good cosmetic results were found among 71.4 % of patients and excellent results among 14.3% of patients, furthermore none of the patients neither local nor regional or distant relapses. Conclusion: among patients who suffer from breast cancer at early stages, it showed is possible to apply partial accelerated radiotherapy upon the tumor bed with high doses over 4 days with good to excellent cosmetic results

  17. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  18. High-dose calcium stimulation test in a case of insulinoma masquerading as hysteria.

    Science.gov (United States)

    Nakamura, Yoshio; Doi, Ryuichiro; Kohno, Yasuhiro; Shimono, Dai; Kuwamura, Naomitsu; Inoue, Koichi; Koshiyama, Hiroyuki; Imamura, Masayuki

    2002-11-01

    It is reported that some cases with insulinoma present with neuropsychiatric symptoms and are often misdiagnosed as psychosis. Here we report a case of insulinoma masquerading as hysteria, whose final diagnosis could be made using high-dose calcium stimulation test. A 28-yr-old woman was referred presenting with substupor, mutism, mannerism, restlessness, and incoherence. Laboratory examinations revealed hypoglycemia (33 mg/dL) and detectable insulin levels (9.7 microU/mL), suggesting the diagnosis of insulinoma. However, neither imaging studies nor selective arterial calcium injection (SACI) test with a conventional dose of calcium (0.025 mEq/kg) indicated the tumor. High-dose calcium injection (0.05 mEq/kg) evoked insulin secretion when injected into superior mesenteric artery. A solitary tumor in the head of the pancreas was resected, and her plasma glucose returned to normal. Postoperatively, iv injection of secretin resulted in a normal response of insulin, which was not found preoperatively. This case suggests the usefulness of the SACI test with high-dose of calcium in the case of insulinoma when the standard dose fails to detect such a tumor.

  19. Base of skull and cervical spine chordomas in children treated by high-dose irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Benk, Veronique; Liebsch, Norbert J; Munzenrider, John E; Efird, John; McManus, Patricia; Suit, Herman

    1995-02-01

    Purpose: To evaluate the outcome of children with base of skull or cervical spine chordomas treated by high dose irradiation. Methods and Materials: Eighteen children, 4 to 18 years of age, with base of skull or cervical spine chordomas, received fractionated high-dose postoperative radiation using mixed photon and 160 MeV proton beams. The median tumor dose was 69 Cobalt Gray-equivalent (CGE) with a 1.8 CGE daily fraction. Results: The median follow-up was 72 months. The 5-year actuarial survival was 68% and the 5-year disease-free survival (DFS) was 63%. The only significant prognostic factor was the location: patients with cervical spine chordomas had a worse survival than those with base of skull lesions (p = 0.008). The incidence of treatment-related morbidity was acceptable: two patients developed a growth hormone deficit corrected by hormone replacement, one temporal lobe necrosis, and one fibrosis of the temporalis muscle, improved by surgery. Conclusion: Chordomas in children behave similarly to those in adults: children can receive the same high-dose irradiation as adults with acceptable morbidity.

  20. The effect of high-dose dronabinol (oral THC) maintenance on cannabis self-administration.

    Science.gov (United States)

    Schlienz, Nicolas J; Lee, Dustin C; Stitzer, Maxine L; Vandrey, Ryan

    2018-06-01

    There is a clear need for advancing the treatment of cannabis use disorders. Prior research has demonstrated that dronabinol (oral THC) can dose-dependently suppress cannabis withdrawal and reduce the acute effects of smoked cannabis. The present study was conducted to evaluate whether high-dose dronabinol could reduce cannabis self-administration among daily users. Non-treatment seeking daily cannabis users (N = 13) completed a residential within-subjects crossover study and were administered placebo, low-dose dronabinol (120 mg/day; 40 mg tid), or high-dose dronabinol (180-240 mg/day; 60-80 mg tid) for 12 consecutive days (order counterbalanced). During each 12-day dronabinol maintenance phase, participants were allowed to self-administer smoked cannabis containing <1% THC (placebo) or 5.7% THC (active) under forced-choice (drug vs. money) or progressive ratio conditions. Participants self-administered significantly more active cannabis compared with placebo in all conditions. When active cannabis was available, self-administration was significantly reduced during periods of dronabinol maintenance compared with placebo maintenance. There was no difference in self-administration between the low- and high-dose dronabinol conditions. Chronic dronabinol dosing can reduce cannabis self-administration in daily cannabis users and suppress withdrawal symptoms. Cannabinoid agonist medications should continue to be explored for therapeutic utility in the treatment of cannabis use disorders. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Prevention of incipient diabetic nephropathy by high-dose thiamine and benfotiamine.

    Science.gov (United States)

    Babaei-Jadidi, Roya; Karachalias, Nikolaos; Ahmed, Naila; Battah, Sinan; Thornalley, Paul J

    2003-08-01

    Accumulation of triosephosphates arising from high cytosolic glucose concentrations in hyperglycemia is the trigger for biochemical dysfunction leading to the development of diabetic nephropathy-a common complication of diabetes associated with a high risk of cardiovascular disease and mortality. Here we report that stimulation of the reductive pentosephosphate pathway by high-dose therapy with thiamine and the thiamine monophosphate derivative benfotiamine countered the accumulation of triosephosphates in experimental diabetes and inhibited the development of incipient nephropathy. High-dose thiamine and benfotiamine therapy increased transketolase expression in renal glomeruli, increased the conversion of triosephosphates to ribose-5-phosphate, and strongly inhibited the development of microalbuminuria. This was associated with decreased activation of protein kinase C and decreased protein glycation and oxidative stress-three major pathways of biochemical dysfunction in hyperglycemia. Benfotiamine also inhibited diabetes-induced hyperfiltration. This was achieved without change in elevated plasma glucose concentration and glycated hemoglobin in the diabetic state. High-dose thiamine and benfotiamine therapy is a potential novel strategy for the prevention of clinical diabetic nephropathy.

  2. Does High-Dose Antimicrobial Chemotherapy Prevent the Evolution of Resistance?

    Science.gov (United States)

    Day, Troy; Read, Andrew F.

    2016-01-01

    High-dose chemotherapy has long been advocated as a means of controlling drug resistance in infectious diseases but recent empirical studies have begun to challenge this view. We develop a very general framework for modeling and understanding resistance emergence based on principles from evolutionary biology. We use this framework to show how high-dose chemotherapy engenders opposing evolutionary processes involving the mutational input of resistant strains and their release from ecological competition. Whether such therapy provides the best approach for controlling resistance therefore depends on the relative strengths of these processes. These opposing processes typically lead to a unimodal relationship between drug pressure and resistance emergence. As a result, the optimal drug dose lies at either end of the therapeutic window of clinically acceptable concentrations. We illustrate our findings with a simple model that shows how a seemingly minor change in parameter values can alter the outcome from one where high-dose chemotherapy is optimal to one where using the smallest clinically effective dose is best. A review of the available empirical evidence provides broad support for these general conclusions. Our analysis opens up treatment options not currently considered as resistance management strategies, and it also simplifies the experiments required to determine the drug doses which best retard resistance emergence in patients. PMID:26820986

  3. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer

    International Nuclear Information System (INIS)

    Oliveira, Jetro Pereira de; Batista, Delano Valdivino Santos; Bardella, Lucia Helena; Carvalho, Arnaldo Rangel

    2009-01-01

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  4. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    Science.gov (United States)

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  5. Extra-high doses detected in the enamel of human teeth in the Techa riverside region

    Energy Technology Data Exchange (ETDEWEB)

    Shishkina, E.A., E-mail: ElenaA.Shishkina@gmail.com [Urals Research Center for Radiation Medicine, 68A, Vorovsky Str., 454076 Chelyabinsk (Russian Federation); Degteva, M.O.; Tolstykh, E.I.; Volchkova, A. [Urals Research Center for Radiation Medicine, 68A, Vorovsky Str., 454076 Chelyabinsk (Russian Federation); Ivanov, D.V. [Institute of Metal Physics, Russian Academy of Sciences, 18 S. Kovalevsky Str, 620041 Yekaterinburg (Russian Federation); Wieser, A. [Helmholtz Zentrum Muenchen, German Research Centre for Environmental Health, D-85764 Neuherberg (Germany); Della Monaca, S. [Istituto Superiore di Sanita, 00161 Rome (Italy); Istituto Regina Elena, 00144 Rome (Italy); Fattibene, P. [Istituto Superiore di Sanita, 00161 Rome (Italy); Istituto Nazionale di Fisica Nucleare, 00161 Rome (Italy)

    2011-09-15

    During the long-term study of tooth enamel by EPR dosimetry for population exposed to radiation due to contamination of the Techa River, it was found out that for some of the tooth donors the dose accumulated in tooth enamel could be as high as several tens of Gy. Such doses were absorbed only in tooth enamel and they should not be associated with exposures to other organs or the whole body. The nature of such doses was discussed in a number of previous papers where it was shown that the source of such doses is {sup 90}Sr incorporated in the calcified dental tissues. However, among specialists in radiation dosimetry who were not involved in the biokinetic studies, the nature and dosimetric significance of extra-high doses in tooth enamel are still raising questions. The aim of the current paper is to summarize the accumulated information on extra-high doses in the teeth of the Techa riverside residents, describe the dose levels observed, explain the nature of extra-high doses in the enamel and discuss their informative value. The paper includes an overview of already published findings and an analysis of information collected in the data bank of the Urals Research Center for Radiation Medicine (URCRM), Chelyabinsk, Russia, which has not been published before.

  6. Base of skull and cervical spine chordomas in children treated by high-dose irradiation

    International Nuclear Information System (INIS)

    Benk, Veronique; Liebsch, Norbert J.; Munzenrider, John E.; Efird, John; McManus, Patricia; Suit, Herman

    1995-01-01

    Purpose: To evaluate the outcome of children with base of skull or cervical spine chordomas treated by high dose irradiation. Methods and Materials: Eighteen children, 4 to 18 years of age, with base of skull or cervical spine chordomas, received fractionated high-dose postoperative radiation using mixed photon and 160 MeV proton beams. The median tumor dose was 69 Cobalt Gray-equivalent (CGE) with a 1.8 CGE daily fraction. Results: The median follow-up was 72 months. The 5-year actuarial survival was 68% and the 5-year disease-free survival (DFS) was 63%. The only significant prognostic factor was the location: patients with cervical spine chordomas had a worse survival than those with base of skull lesions (p = 0.008). The incidence of treatment-related morbidity was acceptable: two patients developed a growth hormone deficit corrected by hormone replacement, one temporal lobe necrosis, and one fibrosis of the temporalis muscle, improved by surgery. Conclusion: Chordomas in children behave similarly to those in adults: children can receive the same high-dose irradiation as adults with acceptable morbidity

  7. High dose per fraction dosimetry of small fields with Gafchromic EBT2 film

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Basavatia, Amar; Bayliss, Adam; Tome, Wolfgang A.

    2011-01-01

    Purpose: Small field dosimetry is prone to uncertainties due to the lack of electronic equilibrium and the use of the correct detector size relative to the field size measured. It also exhibits higher sensitivity to setup errors as well as large variation in output with field size and shape. Radiochromic film is an attractive method for reference dosimetry in small fields due to its ability to provide 2D dose measurements while having minimal impact on the dose distribution. Gafchromic EBT2 has a dose range of up to 40 Gy; therefore, it could potentially be useful for high dose reference dosimetry with high spatial resolution. This is a requirement in stereotactic radiosurgery deliveries, which deliver high doses per fraction to small targets. Methods: Targets of 4 mm and 12 mm diameters were treated to a minimum peripheral dose of 21 Gy prescribed to 80% of the maximum dose in one fraction. Target doses were measured with EBT2 film (both targets) and an ion chamber (12 mm target only). Measured doses were compared with planned dose distributions using profiles through the target and minimum peripheral dose coverage. Results: The measured target doses and isodose coverage agreed with the planned dose within ±1 standard deviation of three measurements, which were 2.13% and 2.5% for the 4 mm and 12 mm targets, respectively. Conclusions: EBT2 film is a feasible dosimeter for high dose per fraction reference 2D dosimetry.

  8. High-dose ascorbic acid decreases cholesterolemic factors of an atherogenic diet in guinea pigs.

    Science.gov (United States)

    Filis, Konstantinos; Anastassopoulou, Aikaterini; Sigala, Fragiska; Theodorou, Dimitrios; Manouras, Andreas; Leandros, Emanouel; Sigalas, Panagiotis; Hepp, Wolfgang; Bramis, John

    2007-03-01

    The study evaluates the effect of a high supplemental dose of ascorbic acid (AA) on plasma concentrations of total cholesterol (TC), triglycerides (TG), total lipids (TL), and lipoprotein fractions high-density, very-low-density-, and low-density lipoprotein (HDL, VLDL, LDL) in guinea pigs fed with atherogenic diet. Group I consisted of 5 normally fed guinea pigs plus a low dose of AA (1 mg/100 g/day), group II consisted of 7 guinea pigs fed with food enriched with 2% cholesterol plus a low dose of AA (1 mg/100 g/day), and group III consisted of 7 guinea pigs fed with food enriched with 2% cholesterol plus a high dose of AA (30 mg/100 g/day). Cholesterolemic factors concentrations were determined after nine weeks. Concentrations of TC, TG, TL, LDL, and VLDL were increased in group II compared to group I (p < 0.01 for all differences). Supplementation with a high dose of AA resulted in decreased concentrations of TC (p < 0.01), TG (p < 0.01), TL (p < 0.01), and LDL (p < 0.01) in group III compared to group II. Additionally, concentration of HDL was increased in group III compared to group II (p < 0.01). High-dose AA supplementation to an atherogenic diet decreases concentrations of TC, TG, TL, and LDL and increases concentration of HDL compared to low-dose AA.

  9. Image-Guided Stereotactic Radiosurgery Using a Specially Designed High-Dose-Rate Linac

    International Nuclear Information System (INIS)

    Bayouth, John E.; Kaiser, Heather S.; Smith, Mark C.; Pennington, Edward C.; Anderson, Kathleen M. C.; Ryken, Timothy C.; Buatti, John M.

    2007-01-01

    Stereotactic radiosurgery and image-guided radiotherapy (IGRT) place enhanced demands on treatment delivery machines. In this study, we describe a high-dose-rate output accelerator as a part of our stereotactic IGRT delivery system. The linac is a Siemens Oncor without a flattening filter, and enables dose rates to reach 1000 monitor units (MUs) per minute. Even at this high-dose-rate, the linac dosimetry system remains robust; constancy, linearity, and beam energy remain within 1% for 3 to 1000 MU. Dose profiles for larger field sizes are not flat, but they are radially symmetric and, as such, able to be modeled by a treatment planning system. Target localization is performed via optical guidance utilizing a 3-dimensional (3D) ultrasound probe coupled to an array of 4 infrared light-emitting diodes. These diodes are identified by a fixed infrared camera system that determines diode position and, by extension, all objects imaged in the room coordinate system. This system provides sub-millimeter localization accuracy for cranial applications and better than 1.5 mm for extracranial applications. Because stereotactic IGRT can require significantly longer times for treatment delivery, the advantages of the high-dose-rate design and its direct impact on IGRT are discussed

  10. Myocardial protection induced by fentanyl in pigs exposed to high-dose adrenaline.

    Science.gov (United States)

    da Luz, Vinicius Fernando; Otsuki, Denise Aya; Gonzalez, Maria Margarita Castro; Negri, Elnara Marcia; Caldini, Elia Garcia; Damaceno-Rodrigues, Nilsa Regina; Malbouisson, Luiz Marcelo Sá; Viana, Bruno Gonçalves; Vane, Matheus Fachini; Carmona, Maria Jose Carvalho

    2015-10-01

    The use of high doses of adrenaline is common in critical patients, especially during cardiac arrest. During these situations, myocardial dysfunction can be a result of multiple factors, including adrenaline use. In addition, opioids have been shown to have anti-arrhythmic and anti-ischemic mechanisms that may confer cardiac protection. This study aimed to evaluate the effects of fentanyl on myocardial function in pigs exposed to high-dose adrenaline. After institutional ethics committee approval, 26 pigs were randomly allocated to receive either 20 μg/kg fentanyl (n = 10; fentanyl group) administered 5 min before five doses of adrenaline (20 μg/kg), equivalent-volume saline (n = 10; saline group) using the same adrenaline dosing protocol, or neither fentanyl nor adrenaline (n = 6; sham group). The fentanyl group showed lower levels of troponin at the end of the sixth hour compared with the saline group (1.91 ± 1.47 vs 5.44 ± 5.35 ng/mL, P = 0.019). Transmission electron microscopy and immunohistochemistry also showed less myocardial injury in the fentanyl group. The conclusion was reached that fentanyl attenuates myocardial injury caused by high-dose adrenaline without blunting the hemodynamic effect of adrenaline. © 2015 Wiley Publishing Asia Pty Ltd.

  11. Paralytic ileus requiring hospitalization secondary to high-dose antipsychotic polypharmacy and benztropine.

    Science.gov (United States)

    Kwiatkowski, Mercedes; Denka, Zachary D; White, Christopher C

    2011-01-01

    Ileus can result from the combined activity of antipsychotic and anticholinergic medications. Despite frequent use, case reports in the literature are sparse. We present a patient who developed a paralytic ileus requiring extended hospitalization. Providers should minimize antipsychotic and concurrent anticholinergic medications, consider prophylactic bowel regimens and monitor for constipation. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Basal Insulin Regimens for Adults with Type 1 Diabetes Mellitus: A Cost-Utility Analysis.

    Science.gov (United States)

    Dawoud, Dalia; Fenu, Elisabetta; Higgins, Bernard; Wonderling, David; Amiel, Stephanie A

    2017-12-01

    To assess the cost-effectiveness of basal insulin regimens for adults with type 1 diabetes mellitus in England. A cost-utility analysis was conducted in accordance with the National Institute for Health and Care Excellence reference case. The UK National Health Service and personal and social services perspective was used and a 3.5% discount rate was applied for both costs and outcomes. Relative effectiveness estimates were based on a systematic review of published trials and a Bayesian network meta-analysis. The IMS CORE Diabetes Model was used, in which net monetary benefit (NMB) was calculated using a threshold of £20,000 per quality-adjusted life-year (QALY) gained. A wide range of sensitivity analyses were conducted. Insulin detemir (twice daily) [iDet (bid)] had the highest mean QALY gain (11.09 QALYs) and NMB (£181,456) per patient over the model time horizon. Compared with the lowest cost strategy (insulin neutral protamine Hagedorn once daily), it had an incremental cost-effectiveness ratio of £7844/QALY gained. Insulin glargine (od) [iGlarg (od)] and iDet (od) were ranked as second and third, with NMBs of £180,893 and £180,423, respectively. iDet (bid) remained the most cost-effective treatment in all the sensitivity analyses performed except when high doses were assumed (>30% increment compared with other regimens), where iGlarg (od) ranked first. iDet (bid) is the most cost-effective regimen, providing the highest QALY gain and NMB. iGlarg (od) and iDet (od) are possible options for those for whom the iDet (bid) regimen is not acceptable or does not achieve required glycemic control. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  13. Efficacy and Safety of Single and Double Doses of Ivermectin versus 7-Day High Dose Albendazole for Chronic Strongyloidiasis

    Science.gov (United States)

    Suputtamongkol, Yupin; Premasathian, Nalinee; Bhumimuang, Kid; Waywa, Duangdao; Nilganuwong, Surasak; Karuphong, Ekkapun; Anekthananon, Thanomsak; Wanachiwanawin, Darawan; Silpasakorn, Saowaluk

    2011-01-01

    , and double doses of oral ivermectin respectively (P = 0.006) in modified intention to treat analysis. No serious adverse event associated with treatment was found in any of the groups. Conclusion/Significance This study confirms that both a single, and a double dose of oral ivermectin taken two weeks apart, is more effective than a 7-day course of high dose albendazole for patients with chronic infection due to S. stercoralis. Double dose of ivermectin, taken two weeks apart, might be more effective than a single dose in patients with concomitant illness. Trial Registration ClinicalTrials.gov NCT00765024 PMID:21572981

  14. Polyethylene glycol hydrogel rectal spacer implantation in patients with prostate cancer undergoing combination high-dose-rate brachytherapy and external beam radiotherapy.

    Science.gov (United States)

    Yeh, Jekwon; Lehrich, Brandon; Tran, Carolyn; Mesa, Albert; Baghdassarian, Ruben; Yoshida, Jeffrey; Torrey, Robert; Gazzaniga, Michael; Weinberg, Alan; Chalfin, Stuart; Ravera, John; Tokita, Kenneth

    2016-01-01

    To present rectal toxicity rates in patients administered a polyethylene glycol (PEG) hydrogel rectal spacer in conjunction with combination high-dose-rate brachytherapy and external beam radiotherapy. Between February 2010 and April 2015, 326 prostate carcinoma patients underwent combination high-dose-rate brachytherapy of 16 Gy (average dose 15.5 Gy; standard deviation [SD] = 1.6 Gy) and external beam radiotherapy of 59.4 Gy (average dose 60.2 Gy; SD = 2.9 Gy). In conjunction with the radiation therapy regimen, each patient was injected with 10 mL of a PEG hydrogel in the anterior perirectal fat space. The injectable spacer (rectal spacer) creates a gap between the prostate and the rectum. The rectum is displaced from the radiation field, and rectal dose is substantially reduced. The goal is a reduction in rectal radiation toxicity. Clinical efficacy was determined by measuring acute and chronic rectal toxicity using the National Cancer Center Institute Common Terminology Criteria for Adverse Events v4.0 grading scheme. Median followup was 16 months. The mean anterior-posterior separation achieved was 1.6 cm (SD = 0.4 cm). Rates of acute Grade 1 and 2 rectal toxicity were 37.4% and 2.8%, respectively. There were no acute Grade 3/4 toxicities. Rates of late Grade 1, 2, and 3 rectal toxicity were 12.7%, 1.4%, and 0.7%, respectively. There were no late Grade 4 toxicities. PEG rectal spacer implantation is safe and well tolerated. Acute and chronic rectal toxicities are low despite aggressive dose escalation. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  15. Intravenous administration of high-dose Paclitaxel reduces gut-associated lymphoid tissue cell number and respiratory immunoglobulin A concentrations in mice.

    Science.gov (United States)

    Moriya, Tomoyuki; Fukatsu, Kazuhiko; Noguchi, Midori; Okamoto, Koichi; Murakoshi, Satoshi; Saitoh, Daizoh; Miyazaki, Masaru; Hase, Kazuo; Yamamoto, Junji

    2014-02-01

    Chemotherapy remains a mainstay of treatment for cancer patients. However, anti-cancer drugs frequently cause a wide range of side effects, including leukopenia and gastrointestinal toxicity. These adverse effects can lead to treatment delays or necessitate temporary dose reductions. Although chemotherapy-related changes in gut morphology have been demonstrated, the influences of chemotherapeutic regimens on gut immunity are understood poorly. This study aimed to examine whether the anti-cancer drug paclitaxel (PTX) impairs gut immunity in mice. Male ICR mice were randomized into three groups: Control, low-dose PTX (low PTX; 2 mg/kg), or high-dose PTX (high PTX; 4 mg/kg). A single intravenous dose was given. On day seven after the injection, lymphocytes from Peyer patches (PP), intraepithelial (IE) spaces, and the lamina propria (LP) were counted and analyzed by flow cytometry (CD4(+), CD8(+), αβTCR(+), γδTCR(+), B220(+)). Immunoglobulin A (IgA) concentrations were measured in small intestinal and respiratory tract washings. Total, CD4(+) and γδTCR(+) lymphocyte numbers in PPs were significantly lower in the high PTX than in the control group. The CD4(+) lymphocyte numbers in the IE spaces were significantly lower in both PTX groups than in the control group. Respiratory tract IgA concentrations were lower in the high PTX than in the control group. The present data suggest high-dose PTX impairs mucosal immunity, possibly rendering patients more vulnerable to infection. Careful dose selection and new therapies may be important for maintaining mucosal immunity during PTX chemotherapy.

  16. Medical preparation container comprising microwave powered sensor assembly

    DEFF Research Database (Denmark)

    2016-01-01

    The present invention relates to a medical preparation container which comprises a microwave powered sensor assembly. The microwave powered sensor assembly comprises a sensor configured to measure a physical property or chemical property of a medical preparation during its heating in a microwave ...... oven. The microwave powered sensor assembly is configured for harvesting energy from microwave radiation emitted by the microwave oven and energize the sensor by the harvested microwave energy.......The present invention relates to a medical preparation container which comprises a microwave powered sensor assembly. The microwave powered sensor assembly comprises a sensor configured to measure a physical property or chemical property of a medical preparation during its heating in a microwave...

  17. Metal-polymer composites comprising nanostructures and applications thereof

    Science.gov (United States)

    Wang, Hsing-Lin [Los Alamos, NM; Jeon, Sea Ho [Dracut, MA; Mack, Nathan H [Los Alamos, NM

    2011-08-02

    Metal-polymer composites, and methods of making and use thereof, said composites comprising a thermally-cured dense polyaniline substrate; an acid dopant; and, metal nanostructure deposits wherein the deposits have a morphology dependent upon the acid dopant.

  18. Immunogenic compositions comprising human immunodeficiency virus (HIV) mosaic Nef proteins

    Science.gov (United States)

    Korber, Bette T [Los Alamos, NM; Perkins, Simon [Los Alamos, NM; Bhattacharya, Tanmoy [Los Alamos, NM; Fischer, William M [Los Alamos, NM; Theiler, James [Los Alamos, NM; Letvin, Norman [Boston, MA; Haynes, Barton F [Durham, NC; Hahn, Beatrice H [Birmingham, AL; Yusim, Karina [Los Alamos, NM; Kuiken, Carla [Los Alamos, NM

    2012-02-21

    The present invention relates to mosaic clade M HIV-1 Nef polypeptides and to compositions comprising same. The polypeptides of the invention are suitable for use in inducing an immune response to HIV-1 in a human.

  19. Outcomes Associated With 3 Treatment Schedules of High-Dose-Rate Brachytherapy Monotherapy for Favorable-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jawad, Maha Saada; Dilworth, Joshua T.; Gustafson, Gary S.; Ye, Hong; Wallace, Michelle [Department of Radiation Oncology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Martinez, Alvaro [Michigan HealthCare Professionals/21" s" t Century Oncology, Farmington Hills, Michigan (United States); Chen, Peter Y. [Department of Radiation Oncology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Krauss, Daniel J., E-mail: DKrauss@beaumont.edu [Department of Radiation Oncology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States)

    2016-03-15

    Purpose: We report the outcomes associated with 3 high-dose-rate (HDR) brachytherapy regimens used as monotherapy for favorable-risk prostate cancer. Methods and Materials: Four hundred ninety-four patients with stage ≤T2b prostate cancer, Gleason score ≤7, and prostate-specific antigen levels ≤15 ng/mL underwent HDR brachytherapy as monotherapy. Of those, 319 received 38 Gy in 4 fractions, 79 received 24 Gy in 2 fractions, and 96 received 27 Gy in 2 fractions. Acute and chronic genitourinary (GU) and gastrointestinal (GI) toxicities were defined as side effects occurring ≤6 and >6 months, respectively, after radiation therapy (RT) and were graded according to the Common Terminology Criteria for Adverse Events version 3.0. The time to toxicity was calculated from the date of RT completion. Variables were analyzed with χ{sup 2} test. P values <.05 were considered significant. Results: The median overall follow-up time was 4 years (range, 5.5, 3.5, and 2.5 years for 38 Gy, 24 Gy, and 27 Gy, respectively, P<.001). Acute and chronic grade ≥2 GU and GI toxicity profiles were similar among groups. Acceptable rates of grade 2 GU toxicities were seen with overall acute/chronic frequency/urgency, dysuria, retention, incontinence, and hematuria rates of 14%/20%, 6%/7%, 7%/4%, 1.5%/2%, and 1.5%/7%, respectively. Minimal grade 3 and no grade 4 or 5 toxicities were seen. Grade 1, 2, and 3 chronic urethral stricture rates were 0.3%, 2%, and 1%, respectively. All GI toxicities were similar between groups, with overall rates of acute/chronic grade 2 diarrhea, rectal pain/tenesmus, rectal bleeding, and proctitis of 1%/1%, <1%/0.5%, 0%/2%, and <1%/1%, respectively. No grade 3, 4, or 5 toxicities were seen. All comparisons were similar for hormone-naïve patients. The median time to maximal GU/GI toxicity was similar between groups, ranging from 1 to 1.6 to 0.9 to 1.2 years, respectively. There were no differences in clinical outcomes between the 3 groups at 5

  20. High-dose Extended-Field Irradiation and High-Dose-Rate Brachytherapy With Concurrent Chemotherapy for Cervical Cancer With Positive Para-Aortic Lymph Nodes

    International Nuclear Information System (INIS)

    Kim, Young Seok; Kim, Jong Hoon; Ahn, Seung Do; Lee, Sang-wook; Shin, Seong Soo; Nam, Joo-Hyun; Kim, Young-Tak; Kim, Yong-Man; Kim, Jong-Hyeok; Choi, Eun Kyung

    2009-01-01

    Purpose: To determine the efficacy and toxicity of extended-field radiotherapy (RT) with concurrent platinum-based chemotherapy in patients with uterine cervical carcinoma and positive para-aortic nodes. Methods and Materials: We retrospectively reviewed the results for 33 women with Stage IB-IVB cervical cancer. Each patient had received 59.4 Gy, including a three-dimensional conformal boost to the para-aortic lymph nodes and 41.4-50.4 Gy of external beam radiotherapy to the pelvis. Each patient also underwent six or seven applications of high-dose-rate brachytherapy (median, 5 Gy to point A at each session). Results: The median follow-up period of surviving patients was 39 months. The most common acute toxicity was hematologic, observed in 23 women. Severe acute and late gastrointestinal toxicity was observed in 3 and 4 patients, respectively. More than three-quarters of patients showed a complete response, encompassing the primary mass, metastatic pelvic, and para-aortic lymph nodes. Of the 33 women, 15 had no evidence of disease, 6 had persistent disease, 4 developed in-field failures, and 6 developed distant failures. The 5-year overall and disease-free survival rate was 47% and 42%, respectively. Conclusion: Concurrent chemoradiotherapy with extended-field radiotherapy is feasible in women with uterine cervical carcinoma and positive para-aortic lymph nodes, with acceptable late morbidity and a high survival rate, although it was accompanied by substantial acute toxicity.

  1. Dielectric electroactive polymers comprising an ionic supramolecular structure

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to an ionic interpenetrating polymer network comprising at least one elastomer and an ionic supramolecular structure comprising the reaction product of at least two chemical compounds wherein each of said compounds has at least two functional groups and wherein said ...... compounds are able to undergo Lewis acid-base reactions. The interpenetrating polymer network may be used as dielectric electroactive polymers (DEAPs) having a high dielectric permittivity....

  2. New Treatment Regimen for Latent Tuberculosis Infection

    Centers for Disease Control (CDC) Podcasts

    2012-03-15

    In this podcast, Dr. Kenneth Castro, Director of the Division of Tuberculosis Elimination, discusses the December 9, 2011 CDC guidelines for the use of a new regimen for the treatment of persons with latent tuberculosis infection.  Created: 3/15/2012 by National Center for HIV/AIDS, Viral Hepatitis, STD, and TB Prevention (NCHHSTP).   Date Released: 3/15/2012.

  3. Calibration procedure for thermoluminescent dosemeters in water absorbed doses for Iridium-192 high dose rate sources

    International Nuclear Information System (INIS)

    Reyes Cac, Franky Eduardo

    2004-10-01

    Thermoluminescent dosimeters are used in brachytherapy services quality assurance programs, with the aim of guaranteeing the correct radiation dose supplied to cancer patients, as well as with the purpose of evaluating new clinical procedures. This work describes a methodology for thermoluminescent dosimeters calibration in terms of absorbed dose to water for 192 Ir high dose rate sources. The reference dose used is measured with an ionization chamber previously calibrated for 192 Ir energy quality, applying the methodology proposed by Toelli. This methodology aims to standardizing the procedure, in a similar form to that used for external radiotherapy. The work evolves the adaptation of the TRS-277 Code of the International Atomic Energy Agency, for small and big cavities, through the introduction for non-uniform experimental factor, for the absorbed dose in the neighborhood of small brachytherapy sources. In order to simulate a water medium around the source during the experimental work, an acrylic phantom was used. It guarantees the reproducibility of the ionization chamber and the thermoluminescent dosimeter's location in relation to the radiation source. The values obtained with the ionization chamber and the thermoluminescent dosimeters, exposed to a 192 Ir high dose rate source, were compared and correction factors for different source-detector distances were determined for the thermoluminescent dosimeters. A numeric function was generated relating the correction factors and the source-detector distance. These correction factors are in fact the thermoluminescent dosimeter calibration factors for the 192 Ir source considered. As a possible application of this calibration methodology for thermoluminescent dosimeters, a practical range of source-detector distances is proposed for quality control of 192 Ir high dose rate sources. (author)

  4. Development of radiation fusion technology with food technology by the application of high dose irradiation

    International Nuclear Information System (INIS)

    Lee, Juwoon; Kim, Jaehun; Choi, Jongil

    2012-04-01

    This study was performed to achieve stable food supply and food safety with radiation fusion technology as a preparation for food weaponization. Results at current stage are following: First, for the development of radiation and food engineering fusion technology using high dose irradiation, the effects of high dose irradiation on food components were evaluated. The combination treatment of irradiation with food engineering was developed. Irradiation condition to destroy radiation resistant foodborne bacteria were determined. Second, for the development of E-beam irradiation technology, the effects of radiation sources on food compounds, processing conditions, and food quality of final products were compared. Food processing conditions for agricultural/aquatic products with different radiation sources was developed and the domination of E-beam irradiation foods were determined. The physical marker for E-beam irradiated foods or not was developed. Third, for the fundamental researches to develop purposed foods to extreme environmental, ready-to-eat foods were developed using high dose irradiation. Food processing for export strategy foods such as process ginseng were developed. Food processing with irradiation to destroy mycotoxin and to inhibit production of mycotoxin was developed. Mathematical models to predict necessary irradiation doses and radiation sources were developed and validated. Through the fundamental researches, the legislation for irradiation approval on meat products, sea foods and dried sea foods, and use of E-beam was introduced. Results from this research project, the followings are expected. Improvement of customer acceptance and activation of irradiation technology by the use of various irradiation rays. Increase of indirect food productivity, and decrease of SOC and improvement of public health by prevention of foodborne outbreaks. Build of SPS/TBT system against imported products and acceleration of domestic product export. Systemized

  5. Development of Radiation Fusion Technology with Food Technology by the Application of High Dose Irradiation

    International Nuclear Information System (INIS)

    Kim, Ju Won; Kim, Jae Hun; Choi, Jong Il

    2010-04-01

    This study was studied to achieve stable food supply and food safety with radiation fusion technology as a preparation for food weaponization. Results at current stage are following: First, for the development of radiation and food engineering fusion technology using high dose irradiation, the effects of high dose irradiation on food components were evaluated. The combination treatment of irradiation with food engineering were developed. Irradiation condition to destroy radiation resistant food borne bacteria were determined. Second, for the development of E-beam irradiation technology, the effects of radiation sources on food compounds, processing conditions, and food quality of final products were compared. Food processing conditions for agricultural/aquatic products with different radiation sources were developed and the domination of E-beam irradiation foods were determined. The physical marker for E-beam irradiated foods or not were developed. Third, for the fundamental researches to develop purposed foods to extreme environmental, ready-to-eat foods were developed using high dose irradiation. Food processing for export strategy foods such as process ginseng were developed. Food processing with irradiation to destroy mycotoxin and to inhibit production of mycotoxin were developed. Mathematical models to predict necessary irradiation doses and radiation sources were developed and validated. Through the fundamental researches, the legislation for irradiation approval on meat products, sea foods and dried sea foods, and use of E-beam were introduced. Results from this research project, the followings are expected. (1) Improvement of customer acceptance and activation of irradiation technology by the use of various irradiation rays. (2) Increase of indirect food productivity, and decrease of SOC and improvement of public health by prevention of food borne outbreaks. (3) Build of SPS/TBT system against imported products and acceleration of domestic product export

  6. Does perioperative high-dose prednisolone have clinical benefits for generalized myasthenia gravis?

    Science.gov (United States)

    Sekine, Yasuo; Kawaguchi, Naoki; Hamada, Chikuma; Sekiguchi, Hiromi; Yasufuku, Kazuhiro; Iyoda, Akira; Shibuya, Kiyoshi; Fujisawa, Takehiko

    2006-06-01

    The purpose of this study was to clarify the clinical benefits of perioperative administration of high-dose prednisolone (PSL) combined with extended thymectomy on the long-term outcomes of 116 consecutive patients with generalized myasthenia gravis (MG). A retrospective review was conducted on 116 patients diagnosed with generalized MG who received alternate-day oral administration of high-dose PSL (100 mg/alternate days) and had undergone transsternal extended thymectomy. Incidences of postoperative myasthenic crisis, adverse effects of steroid, long-term outcomes, such as complete stable remission (CSR), pharmacologic remission (PR) or improvement (Imp), and disease recurrence after CSR were evaluated. Six patients (5.2%) experienced post-thymectomy myasthenic crisis. Crude cumulative CSR and PR + CSR rates were 44.8 and 62.7%, respectively. Life table analysis showed that 41.8, 52.8 and 63.4% of the patients were in CSR at 3, 5 and 10 years, respectively. Multivariate analysis revealed that age and pretreatment classification according to the Myasthenia Gravis Foundation of America (MGFA) criteria tended to be independent predictors of CSR. There were 6.9% with compressive vertebral fracture, 13.8% with cataract, and 5.2% with steroid-induced diabetes. Life table analysis revealed that recurrence rates after CSR were 36.8 and 46.0% at 3 and 5 years, respectively. Patients with thymoma had a significantly higher rate of recurrence than those without thymoma (p = 0.001). Alternate-day administration of high-dose prednisolone reduced the risk of post-thymectomy myasthenic crisis. Presence of thymoma was a risk factor for MG recurrence after CSR.

  7. Development of Radiation Fusion Technology with Food Technology by the Application of High Dose Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ju Won; Kim, Jae Hun; Choi, Jong Il

    2010-04-15

    This study was studied to achieve stable food supply and food safety with radiation fusion technology as a preparation for food weaponization. Results at current stage are following: First, for the development of radiation and food engineering fusion technology using high dose irradiation, the effects of high dose irradiation on food components were evaluated. The combination treatment of irradiation with food engineering were developed. Irradiation condition to destroy radiation resistant food borne bacteria were determined. Second, for the development of E-beam irradiation technology, the effects of radiation sources on food compounds, processing conditions, and food quality of final products were compared. Food processing conditions for agricultural/aquatic products with different radiation sources were developed and the domination of E-beam irradiation foods were determined. The physical marker for E-beam irradiated foods or not were developed. Third, for the fundamental researches to develop purposed foods to extreme environmental, ready-to-eat foods were developed using high dose irradiation. Food processing for export strategy foods such as process ginseng were developed. Food processing with irradiation to destroy mycotoxin and to inhibit production of mycotoxin were developed. Mathematical models to predict necessary irradiation doses and radiation sources were developed and validated. Through the fundamental researches, the legislation for irradiation approval on meat products, sea foods and dried sea foods, and use of E-beam were introduced. Results from this research project, the followings are expected. (1) Improvement of customer acceptance and activation of irradiation technology by the use of various irradiation rays. (2) Increase of indirect food productivity, and decrease of SOC and improvement of public health by prevention of food borne outbreaks. (3) Build of SPS/TBT system against imported products and acceleration of domestic product export

  8. Development of radiation fusion technology with food technology by the application of high dose irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Juwoon; Kim, Jaehun; Choi, Jongil; and others

    2012-04-15

    This study was performed to achieve stable food supply and food safety with radiation fusion technology as a preparation for food weaponization. Results at current stage are following: First, for the development of radiation and food engineering fusion technology using high dose irradiation, the effects of high dose irradiation on food components were evaluated. The combination treatment of irradiation with food engineering was developed. Irradiation condition to destroy radiation resistant foodborne bacteria were determined. Second, for the development of E-beam irradiation technology, the effects of radiation sources on food compounds, processing conditions, and food quality of final products were compared. Food processing conditions for agricultural/aquatic products with different radiation sources was developed and the domination of E-beam irradiation foods were determined. The physical marker for E-beam irradiated foods or not was developed. Third, for the fundamental researches to develop purposed foods to extreme environmental, ready-to-eat foods were developed using high dose irradiation. Food processing for export strategy foods such as process ginseng were developed. Food processing with irradiation to destroy mycotoxin and to inhibit production of mycotoxin was developed. Mathematical models to predict necessary irradiation doses and radiation sources were developed and validated. Through the fundamental researches, the legislation for irradiation approval on meat products, sea foods and dried sea foods, and use of E-beam was introduced. Results from this research project, the followings are expected. Improvement of customer acceptance and activation of irradiation technology by the use of various irradiation rays. Increase of indirect food productivity, and decrease of SOC and improvement of public health by prevention of foodborne outbreaks. Build of SPS/TBT system against imported products and acceleration of domestic product export. Systemized

  9. The biochemical changes of bone collagen after high-dose irradiation

    International Nuclear Information System (INIS)

    Tajiri, Ken

    1980-01-01

    In our clinic, patients with malignant bone tumors have been treated by high-dose irradiation therapy, 10,000-20,000 rads, for primary lesions. In order to study the biochemical changes of normal bone around tumor tissue, especially bone collagen, after high-dose irradiation, the author performed the following experiments. The right knee joint of rabbits was irradiated with either 6,000, 10,000, or 15,000 rads by 60 Co-γ ray. The cortical bone of the right tibial metaphysis was used for analyses and compared with the left tibia of the same rabbit. These studies were followed for one year after the final irradiation. The calcium, phosphorous and collagen contents of irradiated bone were remarkably changed. These data indicate that collagen biosynthesis of irradiated bone was decreased and the calcification was disturbed. An increase in the amount of total soluble collagen and a decrease in the amount of hydroxylysine bound sugar were observed. The ratio of β to α chains of the collagen molecule was also changed by the irradiation. The amount of reducible cross-links per hydroxyproline residue was strikingly increased three months after the final irradiation. These changes were remarkable especially in the 10,000 and 15,000 rads irradiated group and found to be recovered approximately six months to one year after the final irradiation. These findings indicate that high-dose irradiation reduces the stability of bone collagen both with the destruction of sugar bonds of hydroxylysine residues and the replacement of matured collagen matrix to immatured one which contain mostly labile reducible cross-links. (author)

  10. Effects of high dose coffee intake on aerobic power in dragon female athletes

    Directory of Open Access Journals (Sweden)

    Shabani Ramin

    2016-08-01

    Full Text Available Background : There are few studies that consider the effect of high doses of caffeine on aerobic power (VO2max. Also, to date, no study examined the effect of coffee intake on dragon boat paddler specifically on women. The purpose of this study was to investigate the effect of espresso coffee on improvement of aerobic power of dragon boat paddler. Material : Twenty women athletes of Guilan dragon bout team members of Malavan club of port city of Anzali (mean ±SD age, 23.60± 3.49 years; BMI,23.77±1.88kg/m2; body fat, 30.32±4.65% were recruited to this study, after they completed a primary test without consuming any coffee, they consumed 6mg/kg of coffee (espresso or decaffeinated and following that they completed two experimental trials. A randomized, double-blind, repeated-measures, design was employed whereby paddlers complete a 2000m paddling dragon boat ergo-meter. Results : Coffee could improve VO2max (Without coffee =74.40± QUOTE 4.99, Espresso coffee =90.10± QUOTE 6.19, Decaffeinated coffee =91.00± QUOTE 5.67, P≤ QUOTE 0.05. VO2max amount after exercise were significantly higher for both espresso coffee and decaffeinated coffee, when compared with without coffee condition. No significant differences were observed between espresso coffee and decaffeinated coffee (P≤ QUOTE 0.05. Conclusion : The present study shows that both high doses of caffeine (espresso coffee and decaffeinated coffee can enhance VO2max during aerobic exercise including 2000m dragon boat paddling. It seems that some compounds except caffeine in decaffeinated coffee can act improve VO2max. Further studies needed for considering the effect of high doses of coffee on endurance exercises. Also in other age ranges of women athletes and other sport athletes.

  11. Pre-installation empirical testing of room shielding for high dose rate remote afterloaders

    International Nuclear Information System (INIS)

    Klein, E.E.; Grigsby, P.W.; Williamson, J.F.; Meigooni, A.S.

    1993-01-01

    PURPOSE: Many facilities are acquiring high dose rate remote afterloading units. It is economical that these units be placed in existing shielded teletherapy rooms. Scatter-radiation barriers marginally protect uncontrolled areas from a high dose rate source especially in a room that houses a non-dynamic Cobalt-60 unit. In addition the exact thickness and material composition of the barriers are unknown and therefore, a calculation technique may give misleading results. Also, it would be impossible to evaluate an entire wall barrier by taking isolated core samples in order to assist in the calculations. A quick and inexpensive measurement of dose equivalent using a rented high activity 192Ir source evaluates the barriers and locates shielding deficiencies. METHODS AND MATERIALS: We performed transmission calculations for primary and scattered radiation based on National Council on Radiation Protection and Measurements Reports 49 and 51, respectively. We then rented a high activity 21.7 Ci (8.03 x 10(11) Bq) Ir-192 source to assess our existing teletherapy room shielding for adequacy and voids. This source was placed at the proposed location for clinical high dose rate treatment and measurements were performed. RESULTS: No deficiencies were found in controlled areas surrounding the room, but large differences were found between the calculated and measured values. Our survey located a region in the uncontrolled area above the room requiring augmented shielding which was not predicted by the calculations. A canopy shield was designed to potentially augment the shielding in the ceiling direction. CONCLUSION: Pre-installation testing by measurement is an invaluable method for locating shielding deficiencies and avoiding unnecessary enhancement of shielding particularly when there is lack of information of the inherent shielding

  12. Efficacy and Tolerability of High-Dose Escitalopram in Posttraumatic Stress Disorder.

    Science.gov (United States)

    Qi, Wei; Gevonden, Martin; Shalev, Arieh

    2017-02-01

    Open-label trials suggest that escitalopram (up to 20 mg/d) is an effective treatment for some, but not all posttraumatic stress disorder (PTSD) patients. Higher doses of escitalopram effectively reduced major depression symptoms in patients who had not responded to regular doses. The current study examines the efficacy, tolerability, and adherence to high-dose escitalopram in PTSD. Forty-five PTSD patients received 12 weeks of gradually increasing doses of escitalopram reaching 40 mg daily at 4 weeks. Among those, 12 participants received regular doses of antidepressants at study onset including escitalopram (n = 7). The Clinician-Administered PTSD Scale (CAPS) evaluated PTSD symptoms severity before treatment, at 3 months (upon treatment termination), and at 6 months (maintenance effect). A 20% reduction in CAPS scores was deemed clinically significant. Adverse events and medication adherence were monitored at each clinical session. Linear mixed-models analysis showed a significant reduction of mean CAPS scores (11.5 ± 18.1 points) at 3 months and maintenance of gains by 6 months (F2,34.56 = 8.15, P = 0.001). Eleven participants (34.3%) showed clinically significant improvement at 3 months. Only 9 participants (20%) left the study. There were no serious adverse events and few mild ones with only 2 adverse events (diarrhea, 11.1%; drowsiness, 11.1%) reported by more than 10% of participants. High doses of escitalopram are tolerable and well adhered to in PTSD. Their beneficial effect at a group level is due to a particularly good response in a subset of patients.Variability in prior pharmacological treatment precludes a definite attribution of the results to high doses of escitalopram.

  13. High-Dose Citalopram and Escitalopram and the Risk of Out-of-Hospital Death.

    Science.gov (United States)

    Ray, Wayne A; Chung, Cecilia P; Murray, Katherine T; Hall, Kathi; Stein, C Michael

    2017-02-01

    Studies demonstrating that higher doses of citalopram (> 40 mg) and escitalopram (> 20 mg) prolong the corrected QT interval prompted regulatory agency warnings, which are controversial, given the absence of confirmatory clinical outcome studies. We compared the risk of potential arrhythmia-related deaths for high doses of these selective serotonin reuptake inhibitors (SSRIs) to that for equivalent doses of fluoxetine, paroxetine, and sertraline. The Tennessee Medicaid retrospective cohort study included 54,220 persons 30-74 years of age without cancer or other life-threatening illness who were prescribed high-dose SSRIs from 1998 through 2011. The mean age was 47 years, and 76% were female. Demographic characteristics and comorbidity for individual SSRIs were comparable. Because arrhythmia-related deaths are typically sudden and occur outside the hospital, we analyzed out-of-hospital sudden unexpected death as well as sudden cardiac deaths, a more specific indicator of proarrhythmic effects. The adjusted risk of sudden unexpected death for citalopram did not differ significantly from that for the other SSRIs. The respective hazard ratios (HRs) for citalopram versus escitalopram, fluoxetine, paroxetine, and sertraline were 0.84 (95% CI, 0.40-1.75), 1.24 (95% CI, 0.75-2.05), 0.75 (95% CI, 0.45-1.24), and 1.53 (95% CI, 0.91-2.55). There were no significant differences for sudden cardiac death or all study deaths, nor were there significant differences among high-risk patients (≥ 60 years of age, upper quartile baseline cardiovascular risk). Escitalopram users had no significantly increased risk for any study end point. We found no evidence that risk of sudden unexpected death, sudden cardiac death, or total mortality for high-dose citalopram and escitalopram differed significantly from that for comparable doses of fluoxetine, paroxetine, and sertraline. © Copyright 2016 Physicians Postgraduate Press, Inc.

  14. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer.

    Science.gov (United States)

    Martinez, Alvaro A; Gustafson, Gary; Gonzalez, José; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-06-01

    To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level >or=10.0 ng/mL, Gleason score >or=7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause-specific survival with higher doses. These results, coupled with the low risk of complications, the advantage of not being radioactive after implantation, and the real-time interactive planning, define a new standard for treatment.

  15. High-dose alcohol intoxication differentially modulates cognitive subprocesses involved in response inhibition.

    Science.gov (United States)

    Stock, Ann-Kathrin; Schulz, Tom; Lenhardt, Martin; Blaszkewicz, Meinolf; Beste, Christian

    2016-01-01

    Aside from well-known physiological effects, high-dose alcohol intoxication (a.k.a. binge drinking) can lead to aversive social and legal consequences because response inhibition is usually compromised under the influence of alcohol. Although the behavioral aspects of this phenomenon were reported on extensively, the underlying neurophysiological mechanisms mediating this disinhibition are unclear. To close this gap, we used both behavioral and neurophysiological measures (event-related potentials, ERPs) to investigate which subprocesses of response inhibition are altered under the influence of high-dose alcohol intoxication. Using a within-subject design, we asked young healthy participants (n = 27) to complete a GO/NOGO task once sober and once intoxicated (approximately 1.2‰). During intoxication, high-dose alcohol effects were highest in a condition where the participants could not rely on automated stimulus-response mapping processes during response inhibition. In this context, the NOGO-P3 (ERP), that likely depends on dopaminergic signaling within mesocorticolimbic pathways and is thought to reflect motor inhibition and/or the evaluation of inhibitory processes, was altered in the intoxicated state. In contrast to this, the N2 component, which largely depends on nigrostriatal dopamine pathways and is thought to reflect inhibition on a pre-motor level, was not altered. Based on these results, we demonstrate that alcohol-induced changes of dopaminergic neurotransmission do not exert a global effect on response inhibition. Instead, changes are highly subprocess-specific and seem to mainly target mesocorticolimbic pathways that contribute to motor inhibition and the evaluation of such. © 2014 Society for the Study of Addiction.

  16. Acute cognitive effects of high doses of dextromethorphan relative to triazolam in humans

    Science.gov (United States)

    Carter, Lawrence P.; Reissig, Chad J.; Johnson, Matthew W.; Klinedinst, Margaret A.; Griffiths, Roland R.

    2012-01-01

    BACKGROUND Although concerns surrounding high-dose dextromethorphan (DXM) abuse have recently increased, few studies have examined the acute cognitive effects of high doses of DXM. The aim of this study was to compare the cognitive effects of DXM with those of triazolam and placebo. METHODS Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg /70 kg), and placebo were administered p.o. to twelve healthy volunteers with histories of hallucinogen use, under double-blind conditions, using an ascending dose run-up design. Effects on cognitive performance were examined at baseline and after drug administration for up to 6 hours. RESULTS Both triazolam and DXM produced acute impairments in attention, working memory, episodic memory, and metacognition. Impairments observed following doses of 100-300 mg/70 kg DXM were generally smaller in magnitude than those observed after 0.5 mg/70 kg triazolam. Doses of DXM that impaired performance to the same extent as triazolam were in excess of 10-30 times the therapeutic dose of DXM. CONCLUSION The magnitude of the doses required for these effects and the absence of effects on some tasks within the 100-300 mg/70 kg dose range of DXM, speak to the relatively broad therapeutic window of over-the-counter DXM preparations when used appropriately. However, the administration of supratherapeutic doses of DXM resulted in acute cognitive impairments on all tasks that were examined. These findings are likely relevant to cases of high-dose DXM abuse. PMID:22989498

  17. High doses of biotin in chronic progressive multiple sclerosis: a pilot study.

    Science.gov (United States)

    Sedel, Frédéric; Papeix, Caroline; Bellanger, Agnès; Touitou, Valérie; Lebrun-Frenay, Christine; Galanaud, Damien; Gout, Olivier; Lyon-Caen, Olivier; Tourbah, Ayman

    2015-03-01

    No drug has been found to have any impact on progressive multiple sclerosis (MS). Biotin is a vitamin acting as a coenzyme for carboxylases involved in key steps of energy metabolism and fatty acids synthesis. Among others, biotin activates acetylCoA carboxylase, a potentially rate-limiting enzyme in myelin synthesis. The aim of this pilot study is to assess the clinical efficacy and safety of high doses of biotin in patients suffering from progressive MS. Uncontrolled, non-blinded proof of concept study 23 consecutive patients with primary and secondary progressive MS originated from three different French MS reference centers were treated with high doses of biotin (100-300mg/day) from 2 to 36 months (mean=9.2 months). Judgement criteria varied according to clinical presentations and included quantitative and qualitative measures. In four patients with prominent visual impairment related to optic nerve injury, visual acuity improved significantly. Visual evoked potentials in two patients exhibited progressive reappearance of P100 waves, with normalization of latencies in one case. Proton magnetic resonance spectroscopy (H-MRS) in one case showed a progressive normalization of the Choline/Creatine ratio. One patient with left homonymous hemianopia kept on improving from 2 to 16 months following treatment׳s onset. Sixteen patients out of 18 (89%) with prominent spinal cord involvement were considered as improved as confirmed by blinded review of videotaped clinical examination in 9 cases. In all cases improvement was delayed from 2 to 8 months following treatment׳s onset. These preliminary data suggest that high doses of biotin might have an impact on disability and progression in progressive MS. Two double-blind placebo-controlled trials are on going. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  18. Surface applicators for high dose rate brachytherapy in AIDS-related kaposi's sarcoma

    International Nuclear Information System (INIS)

    Evans, Michael D.C.; Yassa, Mariam; Podgorsak, Ervin B.; Roman, Ted N.; Schreiner, L. John; Souhami, Luis

    1997-01-01

    Purpose: The development of commercially available surface applicators using high dose rate remote afterloading devices has enabled radiotherapy centers to treat selected superficial lesions using a remote afterloading brachytherapy unit. The dosimetric parameters of these applicators, the clinical implementation of this technique, and a review of the initial patient treatment regimes are presented. Methods and Materials: A set of six fixed-diameter (1, 2, and 3 cm), tungsten/steel surface applicators is available for use with a single stepping-source (Ir-192, 370 GBq) high dose rate afterloader. The source can be positioned either in a parallel or perpendicular orientation to the treatment plane at the center of a conical aperture that sits at an SSD of approximately 15 mm and is used with a 1-mm thick removable plastic cap. The surface dose rates, percent depth dose, and off-axis ratios were measured. A custom-built, ceiling-mounted immobilization device secures the applicator on the surface of the patient's lesion during treatment. Results: Between November 1994, and September 1996, 16 AIDS-related Kaposi's sarcoma patients having a total of 120 lesions have been treated with palliative intent. Treatment sites were distributed between the head and neck, extremity, and torso. Doses ranged from 8 to 20 Gy, with a median dose of 10 Gy delivered in a single fraction. Treatments were well tolerated with minimal skin reaction, except for patients with lesions treated to 20 Gy who developed moderate/severe desquamation. Conclusion: Radiotherapy centers equipped with a high dose rate remote afterloading unit may treat small selected surface lesions with commercially available surface applicators. These surface applicators must be used with a protective cap to eliminate electron contamination. The optimal surface dose appears to be either 10 or 15 Gy depending upon the height of the lesion

  19. Induction of regulatory T cells by high-dose gp96 suppresses murine liver immune hyperactivation.

    Directory of Open Access Journals (Sweden)

    Xinghui Li

    Full Text Available Immunization with high-dose heat shock protein gp96, an endoplasmic reticulum counterpart of the Hsp90 family, significantly enhances regulatory T cell (Treg frequency and suppressive function. Here, we examined the potential role and mechanism of gp96 in regulating immune-mediated hepatic injury in mice. High-dose gp96 immunization elicited rapid and long-lasting protection of mice against concanavalin A (Con A-and anti-CD137-induced liver injury, as evidenced by decreased alanine aminotransaminase (ALT levels, hepatic necrosis, serum pro-inflammatory cytokines (IFN-γ, TNF-α, and IL-6, and number of IFN-γ (+ CD4(+ and IFN-γ (+ CD8(+ T cells in the spleen and liver. In contrast, CD4(+CD25(+Foxp3(+ Treg frequency and suppressive function were both increased, and the protective effect of gp96 could be generated by adoptive transfer of Treg cells from gp96-immunized mice. In vitro co-culture experiments demonstrated that gp96 stimulation enhanced Treg proliferation and suppressive function, and up-regulation of Foxp3, IL-10, and TGF-β1 induced by gp96 was dependent on TLR2- and TLR4-mediated NF-κB activation. Our work shows that activation of Tregs by high-dose gp96 immunization protects against Con A- and anti-CD137-induced T cell-hepatitis and provides therapeutic potential for the development of a gp96-based anti-immune hyperactivation vaccine against immune-mediated liver destruction.

  20. The Effect of High Dose Radioiodine Therapy on Formation of Radiation Retinopathy During Thyroid Cancer Treatment

    Directory of Open Access Journals (Sweden)

    Tülay Kaçar Güvel

    2014-10-01

    Full Text Available Objective: Non-thyroidal complication of high-dose radioiodine therapy for thyroid carcinoma might cause salivary and lacrimal gland dysfunction, which may be transient or permanent in a dose-dependent manner. However, radiation retinopathy complicating 131I therapy, has not been previously well characterized. The aim of this study was to evaluate the extent of retinal damage among patients who had received high doses of radioiodine treatment. Methods: Forty eyes of 20 patients (3 male, 17 female who received 250-1000 mCi during 131I therapy and on ophthalmological follow up for a year after the last treatment were included in the study. Mean age of the study group was 50 years (range 25-70 years. In ophthalmologic examination, visual acuity was measured in order to determine visual loss. Intraocular pressure was measured in all the patients. Then lens examination was carried out with slit lamp biomicroscopy in order to investigate cataract or partial lens opacities. Fundus observation was carried out through the dilated pupil with slit lamp biomicroscopy using 90 D noncontact lens. Result: The best corrected visual aquity with Snellen chart was found as 1.0 in 36 eyes (90% and between 0.6 and 0.9 (10% in 4 eyes (10%. At the biomicroscopic fundus examination, retinal hemorrhage consistent with radiation retinopathy, microaneurysm, microinfarction, edema or exudation, vitreus hemorrhage, partial or total optical disc pallor indicating papillopathy in the optic disc were not observed in any of the eyes. Conclusion: This result indicates that there is not any significant correlation between repeated high-dose radioiodine therapy and radiation retinopathy in differentiated thyroid carcinomas. Even though there is not a significant restriction in use of higher doses of radioiodine therapy in differentiated thyroid carcinoma, more extensive studies are needed in order to obtain more accurate data on possible occurrence of retinopathy.

  1. Acute Complications After High-Dose Chemotherapy and Stem-Cell Rescue in Pediatric Patients With High-Risk Neuroblastoma Treated in Countries With Different Resources

    Directory of Open Access Journals (Sweden)

    Mahmoud M. Elzembely

    2018-03-01

    Full Text Available Purpose: High-dose chemotherapy with autologous stem-cell rescue (SCR is a key component of high-risk neuroblastoma (HRNB therapy. Carboplatin, etoposide, and melphalan (CEM or busulfan and melphalan (Bu/Mel are the most evaluated, effective high-dose chemotherapy for HRNB on the basis of results from major cooperative group studies. Toxicity profiles vary between these regimens, and practice variation exists regarding the preferred high-dose therapy (HDT. We sought to evaluate the safety of HDT and autologous SCR for HRNB in a resource-limited country (Egypt compared with the resource-rich United States. Patients and Methods: We performed a retrospective comparative review of single CEM-based HDT/SCR outcomes through day 100 for HRNB at the Fred Hutchinson Cancer Research Center (FH in the United States (2005 to 2015 versus Bu/Mel-based HDT at El-Sheikh Zayed Specialized Hospital (SZ in Egypt (2009 to 2015. Results: Forty-four patients at FH and 77 patients at SZ were reviewed. Pretransplant hepatic comorbidities were significantly higher at SZ (29 of 77 v nine of 44; P = .05, with 19 of 77 patients at SZ having hepatitis infection. Engraftment was delayed after SZ-Bu/Mel therapy compared with FH-CEM therapy for neutrophils (median 12 days v 10 days, respectively; P < .001 and platelets (median 20 days v 18 days, respectively; P < .001. Sinusoidal obstruction syndrome occurred later, after SZ-Bu/Mel therapy (median 19 days v 7 days; P = .033, and four of eight cases were fatal (six of eight patients had underlying hepatitis infection, whereas three of three cases after FH-CEM therapy were moderately severe. Resource utilization associated with the number of days with fever, antibiotic use, and the number of transfusions administered was significantly higher after FH-CEM therapy than after SZ-Bu/Mel therapy. Conclusion: Use of autologous stem-cell transplantation is feasible in the context of a resource-limited country.

  2. Assessment of non-standard HIV antiretroviral therapy regimens at ...

    African Journals Online (AJOL)

    2016-03-06

    Mar 6, 2016 ... Most patients were transitioned to standard regimens, ... In cases of first-line regimen treatment failure, ..... tute; National Heart, Lung, and Blood Institute; National. Institute of Dental & Craniofacial Research; National Insti-.

  3. Verification of the calculation program for brachytherapy planning system of high dose rate (PLATO)

    International Nuclear Information System (INIS)

    Almansa, J.; Alaman, C.; Perez-Alija, J.; Herrero, C.; Real, R. del; Ososrio, J. L.

    2011-01-01

    In our treatments are performed brachytherapy high dose rate since 2007. The procedures performed include gynecological intracavitary treatment and interstitial. The treatments are performed with a source of Ir-192 activity between 5 and 10 Ci such that small variations in treatment times can cause damage to the patient. In addition the Royal Decree 1566/1998 on Quality Criteria in radiotherapy establishes the need to verify the monitor units or treatment time in radiotherapy and brachytherapy. All this justifies the existence of a redundant system for brachytherapy dose calculation that can reveal any abnormality is present.

  4. Advantages of high-dose rate (HDR) brachytherapy in treatment of prostate cancer

    Science.gov (United States)

    Molokov, A. A.; Vanina, E. A.; Tseluyko, S. S.

    2017-09-01

    One of the modern methods of preserving organs radiation treatment is brachytherapy. This article analyzes the results of prostate brachytherapy. These studies of the advantages of high dose brachytherapy lead to the conclusion that this method of radiation treatment for prostate cancer has a favorable advantage in comparison with remote sensing methods, and is competitive, preserving organs in comparison to surgical methods of treatment. The use of the method of polyfocal transperineal biopsy during the brachytherapy session provides information on the volumetric spread of prostate cancer and adjust the dosimetry plan taking into account the obtained data.

  5. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Gustafson, Gary; Gonzalez, Jose; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-01-01

    Purpose: To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Methods and Materials: Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level ≥10.0 ng/mL, Gleason score ≥7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. Results: The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p<0.001). Improvement occurred in the cause-specific survival in favor of the brachytherapy high-dose level (p=0.014). On multivariate analysis, a low-dose level, higher Gleason score, and higher nadir value were associated with increased biochemical failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Conclusion: Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause

  6. Effect of high dose irradiation on the red cell span in rabbits

    International Nuclear Information System (INIS)

    Kang, T.W.; Koh, J.W.; Woo, K.S.; Lee, O.H.; Youn, C.S.

    1982-01-01

    As a part of studies on acute effects of high dose irradiation in vivo, the present report was carried out to evaluate the changes of the red cell life span in the white rabbits by a single whole body exposure to gamma rays from 60 Co teletherapy unit. The exposure was done in dose levels of 100, 600 and 900 rads to each experimental group of 10 rabbits. The life span apparent half survival time of red cells, and that the red cell volume in the circulting blood were measured by ICSH Reference method using 51 Cr. (Author)

  7. A double-blind, placebo controlled trial of high-dose lecithin in Alzheimer's disease.

    OpenAIRE

    Little, A; Levy, R; Chuaqui-Kidd, P; Hand, D

    1985-01-01

    The first long-term double-blind placebo controlled trial of high dose lecithin in senile dementia of the Alzheimer type is reported. Fifty one subjects were given 20-25 g/day of purified soya lecithin (containing 90% phosphatidyl plus lysophosphatidyl choline) for six months and followed up for at least a further six months. Plasma choline levels were monitored throughout the treatment period. There were no differences between the placebo group and the lecithin group but there was an improve...

  8. MRI dosimetry using an echo-quotient technique for high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Ansbacher, W.

    1996-01-01

    MRI gel dosimetry is a relatively new technique that has many advantages over conventional methods, and is particularly suited to High Dose Rate (HDR) Brachytherapy. The dosimeter has high spatial resolution and a water-equivalent response over a wide range of photon energies. Because it is an integrating dosimeter, it allows for efficient mapping of the dynamically-produced distributions from an HDR source. As an example of this technique, the dose response, which is calibrated in terms of the change in spin-spin relaxation time, has been used to investigate the anisotropy of an HDR source. (author). 1 fig

  9. Effect of high-dose intravenous vitamin C on inflammation in cancer patients

    Directory of Open Access Journals (Sweden)

    Mikirova Nina

    2012-09-01

    Full Text Available Abstract Background An inflammatory component is present in the microenvironment of most neoplastic tissues. Inflammation and elevated C-reactive protein (CRP are associated with poor prognosis and decreased survival in many types of cancer. Vitamin C has been suggested as having both a preventative and therapeutic role in a number of pathologies when administered at much higher-than-recommended dietary allowance levels. Since in vitro studies demonstrated inhibition of pro-inflammatory pathways by millimolar concentrations of vitamin C, we decided to analyze the effects of high dose IVC therapy in suppression of inflammation in cancer patients. Methods 45 patients with prostate cancer, breast cancer, bladder cancer, pancreatic cancer, lung cancer, thyroid cancer, skin cancer and B-cell lymphoma were treated at the Riordan Clinic by high doses of vitamin C (7.5 g -50 g after standard treatments by conventional methods. CRP and tumor markers were measured in serum or heparin-plasma as a routine analysis. In addition, serum samples were collected before and after the IVCs for the cytokine kit tests. Results According to our data positive response to treatment, which was demonstrated by measurements of C- reactive protein, was found in 75% of patients and progression of the inflammation in 25% of patients. IVC treatments on all aggressive stage cancer patients showed the poor response of treatment. There was correlation between tumor markers (PSA, CEA, CA27.29 and CA15-3 and changes in the levels of C-reactive protein. Our test of the effect of IVC on pro-inflammatory cytokines demonstrated that inflammation cytokines IL-1α, IL-2, IL-8, TNF-α, chemokine eotaxin and CRP were reduced significantly after treatments. Conclusions The high dose intravenous ascorbic acid therapy affects C-reactive protein levels and pro-inflammation cytokines in cancer patients. In our study, we found that modulation of inflammation by IVC correlated with decreases

  10. High dose-rate brachytherapy source position quality assurance using radiochromic film

    International Nuclear Information System (INIS)

    Evans, M.D.C.; Devic, S.; Podgorsak, E.B.

    2007-01-01

    Traditionally, radiographic film has been used to verify high-dose-rate brachytherapy source position accuracy by co-registering autoradiographic and diagnostic images of the associated applicator. Filmless PACS-based clinics that do not have access to radiographic film and wet developers may have trouble performing this quality assurance test in a simple and practical manner. We describe an alternative method for quality assurance using radiochromic-type film. In addition to being easy and practical to use, radiochromic film has some advantages in comparison with traditional radiographic film when used for HDR brachytherapy quality assurance

  11. Peripheral arterial disease in a female using high-dose combined oral contraceptive pills.

    Science.gov (United States)

    Pallavee, P; Samal, Sunita; Samal, Rupal

    2013-01-01

    The association between oral contraceptive (OC) pills and vascular diseases is well-known, although, the present generation of pills is considered to be relatively safer in this regard. Hormonal treatment for severe abnormal uterine bleeding is usually considered after ruling out malignancy, when such bleeding is resistant to all other forms of treatment. We report a case of severe peripheral arterial disease in a female, who had been on high-dose OC pills for an extended period of time for severe uterine bleeding.

  12. On the use of multi-dimensional scaling and electromagnetic tracking in high dose rate brachytherapy

    Science.gov (United States)

    Götz, Th I.; Ermer, M.; Salas-González, D.; Kellermeier, M.; Strnad, V.; Bert, Ch; Hensel, B.; Tomé, A. M.; Lang, E. W.

    2017-10-01

    High dose rate brachytherapy affords a frequent reassurance of the precise dwell positions of the radiation source. The current investigation proposes a multi-dimensional scaling transformation of both data sets to estimate dwell positions without any external reference. Furthermore, the related distributions of dwell positions are characterized by uni—or bi—modal heavy—tailed distributions. The latter are well represented by α—stable distributions. The newly proposed data analysis provides dwell position deviations with high accuracy, and, furthermore, offers a convenient visualization of the actual shapes of the catheters which guide the radiation source during the treatment.

  13. A high dose dosimeter based polyvinyl chloride dyed with malachite green

    International Nuclear Information System (INIS)

    Kattan, M.; Daher, Y.; Alkassiri, H.

    2007-01-01

    Polyvinyl chloride film (PVC) dyed with malachite green has been studied for high dose radiation dosimetry using visible spectrophotometry. A linear relationship between the relative absorbance and the absorbed dose at the wavelength 628 nm in the range of 0-125 kGy was found. The effect of dose rate, irradiation temperature, film thickness and dye intensity were found not to influence the response. The effects of shelf-life and the post-irradiation storage in darkness and indirect daylight conditions on dosimetry performance were discussed. (author)

  14. In phantom calibration of a high dose rate remote afterloading device

    International Nuclear Information System (INIS)

    Alfonso, R.; Tolede, P.; Pich, V.

    1995-01-01

    The high dose-rate (HDR) brachytherapy in Cuba is based on soviet made devices type AGAT-V. In order to calibration one of these for clinical use a method based of the different measurement of absorbed dose at the reference point B in a paraffin phantom was developed. The results of the calibration are shown. From these results an analysis was made of the effective doses to prescription point a considering the Lineal-Quadratic model. The clinical results by using the AGAT-V device are displayed in a comparative way

  15. High-dose treatment with autologous stem cell transplantation versus sequential chemotherapy: the GELA experience.

    Science.gov (United States)

    Bosly, A; Haioun, C; Gisselbrecht, C; Reyes, F; Coiffier, B

    2001-07-01

    Autologous stem-cell transplantation (ASCT) has permitted to deliver high-dose therapy (HDT). In aggressive lymphomas, the GELA group conducted prospective and retrospective studies comparing HDT + ASCT to conventional sequential chemotherapy. In relapsing patients and in partial remission, retrospective studies showed a survival advantage for HDT + ASCT over sequential chemotherapy. In complete response, advantage for HDT + ASCT was demonstrated in a prospective trial only for patients with high intermediate or high risk in the IPI score. The attainment of a maximal reduction of the tumoral mass before going HDT is very important either in first line or in relapsing patients.

  16. Total skin high-dose-rate electron therapy dosimetry using TG-51

    International Nuclear Information System (INIS)

    Gossman, Michael S.; Sharma, Subhash C.

    2004-01-01

    An approach to dosimetry for total skin electron therapy (TSET) is discussed using the currently accepted TG-51 high-energy calibration protocol. The methodology incorporates water phantom data for absolute calibration and plastic phantom data for efficient reference dosimetry. The scheme is simplified to include the high-dose-rate mode conversion and provides support for its use, as it becomes more available on newer linear accelerators. Using a 6-field, modified Stanford technique, one may follow the process for accurate determination of absorbed dose

  17. Applichation of the sulphate ceric dosimetric in the high doses range

    International Nuclear Information System (INIS)

    Prieto Miranda, F.

    1991-01-01

    The ceric-cerous dosimetric system is one of the system more employed in the high dose dosimetry. The spectrophotometric procedure to measure the ceric-concentration is an usual analityc method to determine the absorbed dose. On the other hand, due at increase employ of the irradiation process control. In this paper is realized the ceric-cerous dosimetric calibration in the dose range of 0,6 - 5 kGy and the application in the irradiation process control to differents absorbed dose values

  18. Intravenous high-dose immunotherapy: practical recommendations for use in the treatment of neurological disimmune diseases

    Directory of Open Access Journals (Sweden)

    N. A. Suponeva

    2015-01-01

    Full Text Available Current publication summarizes main indications and benefits of intravenous high-dose immunotherapy (IHI in the treatment of various autoimmune diseases of the peripheral nervous system. Available products of intravenous immunoglobulin (IVIG on the Russian market are reviewed. Tactics for choosing optimal medication for IHI based on its effectiveness and safety are analyzed. Dosage calculation and way of administration of IVIG are described, beeing of a high practical value in neurologist’s daily work.

  19. Application of RADPOS in Vivo Dosimetry for QA of High Dose Rate Brachytherapy

    DEFF Research Database (Denmark)

    Cherpak, A.; Kertzscher Schwencke, Gustavo Adolfo Vladimir; Cygler, J.

    2012-01-01

    cancer, where high dose gradients and movement of the prostate gland can present unique in vivo dosimetry challenges. Financial and technical support has been received from Best Medical Canada and Ascension Technology Corporation. © 2012 American Association of Physicists in Medicine......Purpose: The RADPOS in vivo dosimetry system combines an electromagnetic positioning sensor with MOSFET dosimetry, allowing for simultaneous online measurements of dose and spatial position. In this work, we assess the potential use of RADPOS for measurements of motion and dose during prostate HDR...

  20. Radiation shielding and dose rate distribution for the building of the high dose rate accelerator

    International Nuclear Information System (INIS)

    Matsuda, Koji; Takagaki, Torao; Nakase, Yoshiaki; Nakai, Yohta.

    1984-03-01

    A high dose rate electron accelerator was established at Osaka Laboratory for Radiation Chemistry, Takasaki Establishment, JAERI in the fiscal year of 1975. This report shows the fundamental concept for the radiation shielding of the accelerator building and the results of their calculations which were evaluated through the model experiments. After the construction of the building, the leak radiation was measured in order to evaluate the calculating method of radiation shielding. Dose rate distribution of X-rays was also measured in the whole area of the irradiation room as a data base. (author)

  1. Calibration in a manikin of a high dose rate equipment by remote charge

    International Nuclear Information System (INIS)

    Alfonso La Guardia, Rodolfo; Toledo Jimenez, Pablo; Pich Leon, Victor

    1996-01-01

    The aim of this study was to know the immediate results obtained with laparoscopic cholecystectomy in The use of High Dose Rate brachytherapy in Cuba has been limited to AGAT-V Soviet installations. In order to calibrate one of these installations for its clinical use, it was developed a procedure based on the direct measurement of the dose absorbed in referral point B of a paraffin manikin. Results obtained as a result of calibration are shown. According to these results, it was carried out an evaluation of the effective doses administered on prescription point A by using the linear quadratic model

  2. Collection of radiation resistant characteristics reports for instruments and materials in high dose rate environment

    International Nuclear Information System (INIS)

    Kusano, Joichi

    2008-03-01

    This document presents the collected official reports of radiation irradiation study for the candidate materials to be used in high dose rate environment as J-PARC facility. The effect of radiation damage by loss-beam or secondary particle beam of the accelerators influences the performance and the reliability of various instruments. The knowledge on the radiation resistivity of the materials is important to estimate the life of the equipments, the maintenance interval and dose evaluation for the personnel at the maintenance period. The radiation damage consists with mechanical property, electrical property and gas-evolution property. (author)

  3. Metabolic effects of feeding high doses of propanol and propylacetate to lactating Holstein cows

    DEFF Research Database (Denmark)

    Raun, Birgitte Marie Løvendahl; Kristensen, Niels Bastian

    2012-01-01

    Three lactating Holstein cows implanted with ruminal cannulas and permanent indwelling catheters in major splanchnic blood vessels were used to investigate alcohol metabolism and metabolic effects of feeding high doses of propanol and propylacetate. Cows were fed three diets control (basal ration......; C), propanol (C plus 50 g propanol/kg DM; P), and propylacetate (C plus 50 g propanol/kg DM and 15 g propylacetate/kg DM; PPA) in a 3 × 3 Latin square design with 14 d period. Daily rations were fed in three equally sized portions at 8 hour intervals and 8 hourly sets of ruminal fluid, arterial...

  4. High dose stainless steel swelling data on interior and peripheral oxide fuel pins

    International Nuclear Information System (INIS)

    Boltax, A.; Foster, J.P.; Nayak, U.P.

    1983-01-01

    High dose (2 x 10 23 n/cm 2 , E > 0.1 Mev) swelling data obtained on 20% cold-worked AISI 316 stainless steel (N-lot) cladding from mixed-oxide fuel pins show large differences in swelling incubation dose due to pre-incubation dose temperature changes. Circumferential swelling variations of 1.5 to 4 times were found in peripheral fuel pin cladding which experienced 30 to 60 deg C temperature changes due to movement in a temperature gradient. Consideration is given to the implications of these results to low swelling materials development and core design. (author)

  5. Epithelial regeneration of transposed intestine after high doses of X-irradiation

    International Nuclear Information System (INIS)

    Both, N.J. de; Vermey, M.

    1976-01-01

    The regeneration capacities of normal and transposed small bowel epithelium were compared in rats after applying high doses of X-irradiation. It has been shown that the potency of the mucosa to regenerate was much higher than assumed and that the mucosa could regenerate after single doses varying from 2000 to 5000 R. Even in the villus epithelium and in flat epithelium covering infiltrates of the lamina propria cells survived, which were still able to resume proliferative activity several days after irradiation. (author)

  6. High-dose radiation-induced meningioma following prophylactic cranial irradiation for acute lymphoblastic leukaemia

    International Nuclear Information System (INIS)

    Matsuda, Ryosuke; Nikaido, Yuji; Yamada, Tomonori; Mishima, Hideaki; Tamaki, Ryo

    2005-01-01

    A 12 year-old girl was treated with prophylactic cranial irradiation for acute lymphoblastic leukaemia (ALL). At the age of 39, she was admitted to our hospital for status epilepticus. Computed tomography demonstrated two, enhancing bilateral sided intracranial tumors. After surgery, this patient presented meningiomas which histologically, were of the meningothelial type. The high cure rate in childhood ALL, attributable to aggressive chemotherapy and prophylactic cranial irradiation, is capable of inducing secondary brain tumor. Twelve cases of high-dose radiation-induced meningioma following ALL are also reviewed. (author)

  7. High-dose radiation-induced meningioma following prophylactic cranial irradiation for acute lymphoblastic leukaemia

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Ryosuke; Nikaido, Yuji; Yamada, Tomonori; Mishima, Hideaki; Tamaki, Ryo [National Hospital Organization Osaka Minami Medical Center, Kawachinagano (Japan)

    2005-03-01

    A 12 year-old girl was treated with prophylactic cranial irradiation for acute lymphoblastic leukaemia (ALL). At the age of 39, she was admitted to our hospital for status epilepticus. Computed tomography demonstrated two, enhancing bilateral sided intracranial tumors. After surgery, this patient presented meningiomas which histologically, were of the meningothelial type. The high cure rate in childhood ALL, attributable to aggressive chemotherapy and prophylactic cranial irradiation, is capable of inducing secondary brain tumor. Twelve cases of high-dose radiation-induced meningioma following ALL are also reviewed. (author)

  8. High-dose intravenous vitamin C combined with cytotoxic chemotherapy in patients with advanced cancer: a phase I-II clinical trial.

    Directory of Open Access Journals (Sweden)

    L John Hoffer

    Full Text Available Biological and some clinical evidence suggest that high-dose intravenous vitamin C (IVC could increase the effectiveness of cancer chemotherapy. IVC is widely used by integrative and complementary cancer therapists, but rigorous data are lacking as to its safety and which cancers and chemotherapy regimens would be the most promising to investigate in detail.We carried out a phase I-II safety, tolerability, pharmacokinetic and efficacy trial of IVC combined with chemotherapy in patients whose treating oncologist judged that standard-of-care or off-label chemotherapy offered less than a 33% likelihood of a meaningful response. We documented adverse events and toxicity associated with IVC infusions, determined pre- and post-chemotherapy vitamin C and oxalic acid pharmacokinetic profiles, and monitored objective clinical responses, mood and quality of life. Fourteen patients were enrolled. IVC was safe and generally well tolerated, although some patients experienced transient adverse events during or after IVC infusions. The pre- and post-chemotherapy pharmacokinetic profiles suggested that tissue uptake of vitamin C increases after chemotherapy, with no increase in urinary oxalic acid excretion. Three patients with different types of cancer experienced unexpected transient stable disease, increased energy and functional improvement.Despite IVC's biological and clinical plausibility, career cancer investigators currently ignore it while integrative cancer therapists use it widely but without reporting the kind of clinical data that is normally gathered in cancer drug development. The present study neither proves nor disproves IVC's value in cancer therapy, but it provides practical information, and indicates a feasible way to evaluate this plausible but unproven therapy in an academic environment that is currently uninterested in it. If carried out in sufficient numbers, simple studies like this one could identify specific clusters of cancer type

  9. High-dose intravenous vitamin C combined with cytotoxic chemotherapy in patients with advanced cancer: a phase I-II clinical trial.

    Science.gov (United States)

    Hoffer, L John; Robitaille, Line; Zakarian, Robert; Melnychuk, David; Kavan, Petr; Agulnik, Jason; Cohen, Victor; Small, David; Miller, Wilson H

    2015-01-01

    Biological and some clinical evidence suggest that high-dose intravenous vitamin C (IVC) could increase the effectiveness of cancer chemotherapy. IVC is widely used by integrative and complementary cancer therapists, but rigorous data are lacking as to its safety and which cancers and chemotherapy regimens would be the most promising to investigate in detail. We carried out a phase I-II safety, tolerability, pharmacokinetic and efficacy trial of IVC combined with chemotherapy in patients whose treating oncologist judged that standard-of-care or off-label chemotherapy offered less than a 33% likelihood of a meaningful response. We documented adverse events and toxicity associated with IVC infusions, determined pre- and post-chemotherapy vitamin C and oxalic acid pharmacokinetic profiles, and monitored objective clinical responses, mood and quality of life. Fourteen patients were enrolled. IVC was safe and generally well tolerated, although some patients experienced transient adverse events during or after IVC infusions. The pre- and post-chemotherapy pharmacokinetic profiles suggested that tissue uptake of vitamin C increases after chemotherapy, with no increase in urinary oxalic acid excretion. Three patients with different types of cancer experienced unexpected transient stable disease, increased energy and functional improvement. Despite IVC's biological and clinical plausibility, career cancer investigators currently ignore it while integrative cancer therapists use it widely but without reporting the kind of clinical data that is normally gathered in cancer drug development. The present study neither proves nor disproves IVC's value in cancer therapy, but it provides practical information, and indicates a feasible way to evaluate this plausible but unproven therapy in an academic environment that is currently uninterested in it. If carried out in sufficient numbers, simple studies like this one could identify specific clusters of cancer type, chemotherapy

  10. Mechanism of Action for Anti-radiation Vaccine in Reducing the Biological Impact of High-dose Gamma Irradiation

    Science.gov (United States)

    Maliev, Vladislav; Popov, Dmitri; Jones, Jeffrey A.; Casey, Rachael C.

    2007-01-01

    Ionizing radiation is a major health risk of long-term space travel, the biological consequences of which include genetic and oxidative damage. In this study, we propose an original mechanism by which high doses of ionizing radiation induce acute toxicity. We identified biological components that appear in the lymphatic vessels shortly after gamma irradiation. These radiation-induced toxins, which we have named specific radiation determinants (SRD), were generated in the irradiated tissues and then collected and circulated throughout the body via the lymph circulation and bloodstream. Depending on the type of SRD elicited, different syndromes of acute radiation sickness (ARS) were expressed. The SRDs were developed into a vaccine used to confer active immunity against acute radiation toxicity in immunologically naive animals. Animals that were pretreated with SRDs exhibited resistance to lethal doses of gamma radiation, as measured by increased survival times and survival rates. In comparison, untreated animals that were exposed to similar large doses of gamma radiation developed acute radiation sickness and died within days. This phenomenon was observed in a number of mammalian species. Initial analysis of the biochemical characteristics indicated that the SRDs were large molecular weight (200-250 kDa) molecules that were comprised of a mixture of protein, lipid, carbohydrate, and mineral. Further analysis is required to further identify the SRD molecules and the biological mechanism by which the mediate the toxicity associated with acute radiation sickness. By doing so, we may develop an effective specific immunoprophylaxis as a countermeasure against the acute effects of ionizing radiation.

  11. [Late sequelae of central nervous system prophylaxis in children with acute lymphoblastic leukemia: high doses of intravenous methotrexate versus radiotherapy of the central nervous system--review of literature].

    Science.gov (United States)

    Zając-Spychała, Olga; Wachowiak, Jacek

    2012-01-01

    Acute lymphoblastic leukemia is the most common malignancy in children. All current therapy regimens used in the treatment of childhood acute lymphoblastic leukemia include prophylaxis of the central nervous system. Initially it was thought that the best way of central nervous system prophylaxis is radiotherapy. But despite its effectiveness this method, may cause late sequelae and complications. In the programme currently used in Poland to treat acute lymphoblastic leukemia, prophylactic radiotherapy has been reduced by 50% (12 Gy) and is used only in patients stratified into the high risk group and in patients diagnosed as T-cell ALL (T-ALL). Complementary to radiotherapy, intrathecal methotrexate is given alone or in combination with cytarabine and hydrocortisone is given, as well as systemic chemotherapy with intravenous methotrexate is administered in high or medium doses (depending on risk groups and leukemia immunophenotype). Recent studies have shown that high dose irradiation of the central nervous system impairs cognitive development causing memory loss, visuomotor coordination impairment, attention disorders and reduction in the intelligence quotient. It has been proved that the degree of cognitive impairment depends on the radiation dose directed to the medial temporal lobe structures, particularly in the hippocampus and the surrounding cortex. Also, methotrexate used intravenously in high doses, interferes with the metabolism of folic acid which is necessary for normal development and the optimal functioning of neurons in the central nervous system. It has been proved that patients who have been treated with high doses of methotrexate are characterized by reduced memory skills and a lower intelligence quotient. The literature data concerning long term neuroanatomical abnormalities and neuropsychological deficits are ambiguous, and there is still no data concerning current methods of central nervous system prophylaxis with low doses of irradiation in

  12. Compositions, methods, and systems comprising fluorous-soluble polymers

    Science.gov (United States)

    Swager, Timothy M.; Lim, Jeewoo; Takeda, Yohei

    2015-10-13

    The present invention generally relates to compositions, methods, and systems comprising polymers that are fluorous-soluble and/or organize at interfaces between a fluorous phase and a non-fluorous phase. In some embodiments, emulsions or films are provided comprising a polymer. The polymers, emulsions, and films can be used in many applications, including for determining, treating, and/or imaging a condition and/or disease in a subject. The polymer may also be incorporated into various optoelectronic device such as photovoltaic cells, organic light-emitting diodes, organic field effect transistors, or the like. In some embodiments, the polymers comprise pi-conjugated backbones, and in some cases, are highly emissive.

  13. Techniques for high dose dosimetry in industry, agriculture and medicine. Proceedings of a symposium

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    In radiation processing, it is important that the irradiated products are reliable and safe. For processes that impact directly on public health, dosimetry provides a formal means of regulation. For other applications, measurements are indispensable for process control to improve quality and the measurements have to be standardized. Thus, dosimetry is an essential part of quality standards for radiation processes. In the developing world, establishment of such quality standards is only in the embryonic stage, and the IAEA should and does play a role in the development and implementation of these standards. The IAEA initiated a programme of high dose dosimetry in 1977 to accomplish dose standardization on an industrial scale, to promote dosimetry as a quality control measure in radiation processing, and to help develop new dosimetry techniques. Since dosimetry has such a key role in these processes, the IAEA organized this international symposium to provide a forum for presentation and discussion of up-to-date developments in this field. Since the International Symposium on High Dose Dosimetry for Radiation Processing held in 1990 the field of dosimetry has deepened and broadened. There is a definite shift towards quality assurance, which calls for dependable dosimetry systems with well established traceability to national or international standards. Also, many new applications of radiation have been developed and for these new and innovative dosimetry methods are needed. This symposium has provided a forum for the discussion of many of these developments and consideration of the outstanding issues in these vital areas Refs, figs, tabs

  14. Techniques for high dose dosimetry in industry, agriculture and medicine. Proceedings of a symposium

    International Nuclear Information System (INIS)

    1999-03-01

    In radiation processing, it is important that the irradiated products are reliable and safe. For processes that impact directly on public health, dosimetry provides a formal means of regulation. For other applications, measurements are indispensable for process control to improve quality and the measurements have to be standardized. Thus, dosimetry is an essential part of quality standards for radiation processes. In the developing world, establishment of such quality standards is only in the embryonic stage, and the IAEA should and does play a role in the development and implementation of these standards. The IAEA initiated a programme of high dose dosimetry in 1977 to accomplish dose standardization on an industrial scale, to promote dosimetry as a quality control measure in radiation processing, and to help develop new dosimetry techniques. Since dosimetry has such a key role in these processes, the IAEA organized this international symposium to provide a forum for presentation and discussion of up-to-date developments in this field. Since the International Symposium on High Dose Dosimetry for Radiation Processing held in 1990 the field of dosimetry has deepened and broadened. There is a definite shift towards quality assurance, which calls for dependable dosimetry systems with well established traceability to national or international standards. Also, many new applications of radiation have been developed and for these new and innovative dosimetry methods are needed. This symposium has provided a forum for the discussion of many of these developments and consideration of the outstanding issues in these vital areas

  15. High-dose proton beam therapy for sinonasal mucosal malignant melanoma

    International Nuclear Information System (INIS)

    Fuji, Hiroshi; Yoshikawa, Shusuke; Kasami, Masako; Murayama, Shigeyuki; Onitsuka, Tetsuro; Kashiwagi, Hiroya; Kiyohara, Yoshio

    2014-01-01

    The significance of definitive radiotherapy for sinonasal mucosal melanoma (SMM) is sill controvertial. This study was to evaluate the role of high-dose proton beam therapy (PBT) in patients with SMM. The cases of 20 patients with SMM localized to the primary site who were treated by PBT between 2006 and 2012 were retrospectively analyzed. The patterns of overall survival and morbidity were assessed. The median follow-up time was 35 months (range, 6–77 months). The 5-year overall and disease-free survival rates were 51% and 38%, respectively. Four patients showed local failure, 2 showed regrowth of the primary tumor, and 2 showed new sinonasal tumors beyond the primary site. The 5-year local control rate after PBT was 62%. Nodal and distant failure was seen in 7 patients. Three grade 4 late toxicities were observed in tumor-involved optic nerve. Our findings suggested that high-dose PBT is an effective local treatment that is less invasive than surgery but with comparable outcomes

  16. The use of caffeine to assess high dose exposures to ionising radiation by dicentric analysis

    International Nuclear Information System (INIS)

    Pujol, M.; Puig, R.; Caballin, M. R.; Barrios, L.; Barquinero, J. F.

    2012-01-01

    Dicentric analysis is considered as a 'gold standard' method for biological dosimetry. However, due to the radiation-induced mitotic delay or inability to reach mitosis of heavily damaged cells, the analysis of dicentrics is restricted to doses up to 4-5 Gy. For higher doses, the analysis by premature chromosome condensation technique has been proposed. Here, it is presented a preliminary study is presented in which an alternative method to analyse dicentrics after high dose exposures to ionising radiation (IR) is evaluated. The method is based on the effect of caffeine in preventing the G2/M checkpoint allowing damaged cells to reach mitosis. The results obtained indicate that the co-treatment with Colcemide and caffeine increases significantly increases the mitotic index, and hence allows a more feasible analysis of dicentrics. Moreover in the dose range analysed, from 0 to 15 Gy, the dicentric cell distribution followed the Poisson distribution, and a simulated partial-body exposure has been clearly detected. Overall, the results presented here suggest that caffeine has a great potential to be used for dose-assessment after high dose exposure to IR. (authors)

  17. High-dose steroid therapy for idiopathic optic perineuritis: a case series

    Directory of Open Access Journals (Sweden)

    Mimura Tatsuya

    2010-12-01

    Full Text Available Abstract Introduction It has been reported that the prognosis of optic perineuritis may be poor when initiation of treatment is delayed. Here we report the successful treatment of three patients with idiopathic optic perineuritis, including two in whom initiation of therapy was delayed. Case presentation Three Japanese patients (two women aged 73 and 66 years, and one man aged 27 years presented with loss of vision (for five months, several months, and two months respectively and pain on eye movement in the third case only, and were diagnosed as having idiopathic optic perineuritis. Fat-suppressed T2-weighted magnetic resonance images showed high signal intensity areas around the affected optic nerves, suggesting the presence of optic perineuritis. Two patients received steroid pulse therapy and the third was given high-dose steroid therapy. The visual acuity improved in all three cases. Conclusion High-dose steroid therapy may be effective for idiopathic perineuritis in patients without optic nerve atrophy, even if initial treatment (including moderate-dose steroids has failed.

  18. Effects of high dose rate gamma radiation on survival and reproduction of Biomphalaria glabrata

    International Nuclear Information System (INIS)

    Cantinha, Rebeca S.; Nakano, Eliana; Silva, Luanna R.S.

    2009-01-01

    Ionizing radiations are known as mutagenic agents, causing lethality and infertility. This characteristic has motivated its application on animal biological control. In this context, the freshwater snail Biomphalaria glabrata can be considered an excellent experimental model to study effects of ionizing radiations on lethality and reproduction. This work was designed to evaluate effects of 60 Co gamma radiation at high dose rate (10.04 kGy/h) on B. glabrata. For this purpose, adult snails were selected and exposed to doses ranging from 20 to 100 Gy, with 10 Gy intervals; one group was kept as control. There was not effect of dose rate in the lethality of gamma radiation; the value of 64,3 Gy of LD 50 obtained in our study was similar to that obtained by other authors with low dose rates. Nevertheless, our data suggest that there was a dose rate effect in the reproduction. On all dose levels, radiation improved the production of embryos for all exposed individuals. However, viability indexes were below 6% and, even 65 days after irradiation, fertility was not recovered. These results are not in agreement with other studies using low dose rates. Lethality was obtained in all groups irradiated, and the highest doses presented percentiles of dead animals above 50%. The results demonstrated that doses of 20 and 30 Gy were ideal for population control of B. glabrata. Further studies are needed; nevertheless, this research evidenced great potential of high dose rate gamma radiation on B. glabrata reproductive control. (author)

  19. Early and late effects of local high dose radiotherapy of the brain on memory and attention

    International Nuclear Information System (INIS)

    Duchstein, S.; Gademann, G.; Peters, B.

    2003-01-01

    Early and Late Effects of Local High Dose Radiotherapy of the Brain on Memory and Attention Background: Stereotactic radiotherapy of benign tumors of the base of skull shows excellent tumor control and long survival. Aim is to study the impact of high dose radiation therapy on functions of memory and attention over time. Patients and Methods: 21 patients (age 42 ± 11 years) with tumors of the base of skull (meningiomas, pituitary gland adenomas) were treated by fractionated stereotactic radiotherapy (mean total dose 56,6 Gy/1,8 Gy). Comprehensive neuropsychological tests and MRI brain scans were performed before, 3, 9 and 21 months after therapy. 14 healthy volunteers were tested in parallel at baseline. In the follow-ups patients were their own controls. Results: In pretreatment tests there were significantly worse test results in comparison to the control group in ten of 32 tests. In postradiation tests only few changes were found in the early-delayed period and not much difference was seen in comparison to the baseline tests. In MRI scans tumor recurrences or radiation induced changes were not found. Conclusion: Radiation with high local doses in target volume extremely close to sensitive brain structures like temporal lobes did not induce significant decline of cognitive functions. (orig.) [de

  20. Mechanical Performance of Ferritic Martensitic Steels for High Dose Applications in Advanced Nuclear Reactors

    Science.gov (United States)

    Anderoglu, Osman; Byun, Thak Sang; Toloczko, Mychailo; Maloy, Stuart A.

    2013-01-01

    Ferritic/martensitic (F/M) steels are considered for core applications and pressure vessels in Generation IV reactors as well as first walls and blankets for fusion reactors. There are significant scientific data on testing and industrial experience in making this class of alloys worldwide. This experience makes F/M steels an attractive candidate. In this article, tensile behavior, fracture toughness and impact property, and creep behavior of the F/M steels under neutron irradiations to high doses with a focus on high Cr content (8 to 12) are reviewed. Tensile properties are very sensitive to irradiation temperature. Increase in yield and tensile strength (hardening) is accompanied with a loss of ductility and starts at very low doses under irradiation. The degradation of mechanical properties is most pronounced at martensitic steels exhibit a high fracture toughness after irradiation at all temperatures even below 673 K (400 °C), except when tested at room temperature after irradiations below 673 K (400 °C), which shows a significant reduction in fracture toughness. Creep studies showed that for the range of expected stresses in a reactor environment, the stress exponent is expected to be approximately one and the steady state creep rate in the absence of swelling is usually better than austenitic stainless steels both in terms of the creep rate and the temperature sensitivity of creep. In short, F/M steels show excellent promise for high dose applications in nuclear reactors.

  1. On-Line High Dose-rate Gamma Irradiation Test of the Profibus/DP module

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Wan; Choi, Young Soo; Kim, Chang Hoi; Koo, In Soo; Hong, Seok Boong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2009-05-15

    The field bus data communication is considered for application in nuclear environments. The nuclear facilities, including nuclear power plants, high radioactivity waste disposals, reprocessing plants and thermonuclear fusion installations can benefit from the unique advantages of the field bus communication network for the smart field instruments and controls. A major problem which arises when dealing with one in these nuclear environments, in special circumstances such as the RCS (reactor coolant system) area, is the presence of high gamma-ray irradiation fields. Radioactive constraints for the DBA(design basis accident) qualification of the RTD transmitter installed in the inside of the RCS pump are typically on the order of 4kGy/h with total doses up to 10kGy. In order to use an industrial field bus communication network as an ad-hoc sensor data link in the vicinity of the RCS area of the nuclear power plant, the robust survivability of these system in such intense gamma-radiation fields therefore needs to be verified. We have conducted high dose-rate (up to 4kGy) gamma irradiation experiments on a profibus/DP communication module. In this paper we describe the evolution of its basic characteristics with high dose-rate gamma irradiation and shortly explain the observed phenomena.

  2. Quality of life in a cohort of high-dose benzodiazepine dependent patients.

    Science.gov (United States)

    Lugoboni, Fabio; Mirijello, Antonio; Faccini, Marco; Casari, Rebecca; Cossari, Anthony; Musi, Gessica; Bissoli, Giorgia; Quaglio, Gianluca; Addolorato, Giovanni

    2014-09-01

    Benzodiazepines (BZD) are among the most widely prescribed drugs in developed countries. Since BZD can produce tolerance and dependence even in a short time, their use is recommended for a very limited time. However, these recommendations have been largely disregarded. The chronic use of BZD causes a number of serious side effects, i.e., cognitive impairment, falls, traffic accidents, dependence and tolerance. The aim of the present study was to evaluate quality of life (QoL) in a cohort of 62 consecutive high-dose BZD-dependent patients seeking a BZD detoxification. Patients seeking BZD detoxification were evaluated using the General Health Questionnaire (GHQ-12) and the short form-36 questionnaire (SF-36). Patients showed a significant reduction of QoL as measured by either SF-36 or GHQ-12. In particular, the greater impairment was observed in the items exploring physical and emotional status. Physical functioning was the item more influenced by the length of BZD abuse. Female patients showed a greater reduction of QoL compared to male, at least in some of the explored items. Social functioning scores were greatly reduced. The present study shows for the first time that high-doses BZD dependent patients have a reduced QoL and a reduced social functioning, along with high levels of psychological distress. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Dosimetric properties of bio minerals applied to high-dose dosimetry using the TSEE technique

    International Nuclear Information System (INIS)

    Vila, G. B.; Caldas, L. V. E.

    2014-08-01

    The study of the dosimetric properties such as reproducibility, the residual signal, lower detection dose, dose-response curve and fading of the thermally stimulated emission exo electronic (TSEE) signal of Brazilian bio minerals has shown that these materials present a potential use as radiation dosimeters. The reproducibility within ± 10% for oyster shell, mother-of-pearl and coral reef samples showed that the signal dispersion is small when compared with the mean value of the measurements. The study showed that the residual signal can be eliminated with a thermal treatment at 300 grades C/1 h. The lower detection dose of 9.8 Gy determined for the oyster shell samples when exposed to beta radiation and 1.6 Gy for oyster shell and mother-of-pearl samples when exposed to gamma radiation can be considered good, taking into account the high doses of this study. The materials presented linearity at the dose response curves in some ranges, but the lack of linearity in other cases presents no problem since a good mathematical description is possible. The fading study showed that the loss of TSEE signal can be minimized if the samples are protected from interferences such as light, heat and humidity. Taking into account the useful linearity range as the main dosimetric characteristic, the tiger shell and oyster shell samples are the most suitable for high-dose dosimetry using the TSEE technique. (Author)

  4. Effects of high dose rate gamma radiation on survival and reproduction of Biomphalaria glabrata

    Energy Technology Data Exchange (ETDEWEB)

    Cantinha, Rebeca S.; Nakano, Eliana [Instituto Butantan, Sao Paulo, SP (Brazil). Lab. de Parasitologia], e-mail: rebecanuclear@gmail.com, e-mail: eliananakano@butantan.gov.br; Borrely, Sueli I. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes], e-mail: sborrely@ipen.br; Amaral, Ademir; Melo, Ana M.M.A. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Estudos em Radioprotecao e Radioecologia (GERAR)], e-mail: amaral@ufpe.br; Silva, Luanna R.S. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Biofisica e Radiobiologia. Lab. de Radiobiologia], e-mail: amdemelo@hotmail.com, e-mail: luannaribeiro_lua@hotmail.com

    2009-07-01

    Ionizing radiations are known as mutagenic agents, causing lethality and infertility. This characteristic has motivated its application on animal biological control. In this context, the freshwater snail Biomphalaria glabrata can be considered an excellent experimental model to study effects of ionizing radiations on lethality and reproduction. This work was designed to evaluate effects of {sup 60}Co gamma radiation at high dose rate (10.04 kGy/h) on B. glabrata. For this purpose, adult snails were selected and exposed to doses ranging from 20 to 100 Gy, with 10 Gy intervals; one group was kept as control. There was not effect of dose rate in the lethality of gamma radiation; the value of 64,3 Gy of LD{sub 50} obtained in our study was similar to that obtained by other authors with low dose rates. Nevertheless, our data suggest that there was a dose rate effect in the reproduction. On all dose levels, radiation improved the production of embryos for all exposed individuals. However, viability indexes were below 6% and, even 65 days after irradiation, fertility was not recovered. These results are not in agreement with other studies using low dose rates. Lethality was obtained in all groups irradiated, and the highest doses presented percentiles of dead animals above 50%. The results demonstrated that doses of 20 and 30 Gy were ideal for population control of B. glabrata. Further studies are needed; nevertheless, this research evidenced great potential of high dose rate gamma radiation on B. glabrata reproductive control. (author)

  5. Prognosis of emergency room stabilization of decompensated congestive heart failure with high dose lasix

    Directory of Open Access Journals (Sweden)

    Mahboob Pouraghaei

    2015-06-01

    Full Text Available Objective: Congestive heart failure (CHF has become one of the most important health care problems in western countries. This article focuses on the outpatient diagnosis and management of heart failure. We want to compare the outcome of patients who were treated with high dose diuretics in the emergency department (ED without admission with patients who were admitted to hospital for standard treatment. Methods: This was a randomized prospective clinical trial study. The patients who came to the ED from March 20, 2008 up to August 20, 2008 were divided into two groups randomly. The length of ED stay in the experimental group was documented. Also, readmission and mortality in 6 months and satisfaction in both groups were taken into consideration. All data were analyzed using SPSS 15.0. Results: In experimental group, the rate of recurrent admission, expiration, discharge, clinic visit, and clinic admission was 8%, 4%, 29%, 18%, and 0% respectively. On the other hand, in control group it was 16%, 40%, 18%, 22%, and 2% respectively. Additionally, there was a significant difference between these groups (P = 0.00. Conclusion: This study is the first regional prospective trial to comprehensively examine the therapeutic management in patients with CHF. This study, comparing the high dose diuretic efficacy in the decreasing of hospital stay and readmission; and decreasing mortality rate with routine therapy, showed that there was a significant difference between these two strategies in the mortality rate, readmission, and length of hospital stay (P = 0.00.

  6. Radiation safety program in high dose rate brachytherapy facility at INHS Asvini

    Directory of Open Access Journals (Sweden)

    Kirti Tyagi

    2014-01-01

    Full Text Available Brachytherapy concerns primarily the use of radioactive sealed sources which are inserted into catheters or applicators and placed directly into tissue either inside or very close to the target volume. The use of radiation in treatment of patients involves both benefits and risks. It has been reported that early radiation workers had developed radiation induced cancers. These incidents lead to continuous work for the improvement of radiation safety of patients and personnel The use of remote afterloading equipment has been developed to improve radiation safety in the delivery of treatment in brachytherapy. The widespread adoption of high dose rate brachytherapy needs appropriate quality assurance measures to minimize the risks to both patients and medical staff. The radiation safety program covers five major aspects: quality control, quality assurance, radiation monitoring, preventive maintenance, administrative measures and quality audit. This paper will discuss the radiation safety program developedfor a high dose rate brachytherapy facility at our centre which may serve as a guideline for other centres intending to install a similar facility.

  7. Low- and high-dose laser irradiation effects on cell migration and destruction

    Science.gov (United States)

    Layton, Elivia; Gallagher, Kyra A.; Zukerman, Sara; Stevens, Brianna; Zhou, Feifan; Liu, Hong; Chen, Wei R.

    2018-02-01

    Metastases are the cause of more than 90 percent of cancer-related deaths. Current treatment methods, including chemotherapy, radiation, and surgery, fail to target the metastases effectively. One potential treatment for metastatic cancer is laser immunotherapy (LIT). LIT combines the use of a photothermal laser with an immunoadjuvant, Glycated Chitosan (GC). GC combined with single-walled carbon nanotubes (SWNTs) has proven to be a viable alternative to traditional cancer treatment methods, when under irradiation of laser with appropriate wavelength. In this study, the effects of low dose and high dose laser irradiation on metastatic pancreatic cancer cell migration were observed. It was found that low dose irradiation increased the migration rate, but the high dose irradiation significantly decreased the migration rate of the cancer cells. When using LIT, the goal is to kill tumor cells and to prompt the correct immune response. If the tumor were irradiated with a low dose, it would promote metastasis. If the dose of irradiation were too high, it would destroy the entire tumor and the immune response would not recognize the tumor. Therefore, the laser dose plays an important role in LIT, particularly when using SWNT as light absorbing agent. Our results from this study will delineate the optimal laser irradiation dose for destroying tumor cells and at the same time preserve and release tumor antigens as a precursor of antitumor immune response.

  8. Dose-reduction techniques for high-dose worker groups in nuclear power plants

    International Nuclear Information System (INIS)

    Khan, T.A.; Baum, J.W.; Dionne, B.J.

    1991-03-01

    This report summarizes the main findings of a study of the extent of radiation dose received by special work groups in the nuclear power industry. Work groups which chronically get large doses were investigated, using information provided by the industry. The tasks that give high doses to these work groups were examined and techniques described that were found to be particularly successful in reducing dose. Quantitative information on the extent of radiation doses to various work groups shows that significant numbers of workers in several critical groups receive doses greater than 1 and even 2 rem per year, particularly contract personnel and workers at BWR-type plants. The number of radiation workers whose lifetime dose is greater than their age is much less. Although the techniques presented would go some way in reducing dose, it is likely that a sizeable reduction to the high-dose work groups may require development of new dose-reduction techniques as well as major changes in procedures. 10 refs., 26 tabs

  9. High-dose-rate brachytherapy using molds for oral cavity cancer. The technique and its limitations

    International Nuclear Information System (INIS)

    Nishimura, Yasumasa; Yokoe, Yoshihiko; Nagata, Yasushi; Okajima, Kaoru; Nishida, Mitsuo; Hiraoka, Masahiro

    1998-01-01

    With the availability of a high-dose-rate (HDR) remote afterloading device, a Phase I/II protocol was initiated at our institution to assess the toxicity and efficacy of HDR intracavitary brachytherapy, using molds, in the treatment of squamous cell carcinomas of the oral cavity. Eight patients with squamous cell carcinoma of the oral cavity were treated by the technique. The primary sites of the tumors were the buccal mucosa, oral floor, and gingiva. Two of the buccal mucosal cancers were located in the retromolar trigon. For each patient, a customized mold was fabricated, in which two to four afterloading catheters were placed for an 192 Ir HDR source. Four to seven fractions of 3-4 Gy, 5 mm below the mold surface, were given following external radiation therapy of 40-60 Gy/ 2 Gy. The total dose of HDR brachytherapy ranged from 16 to 28Gy. Although a good initial complete response rate of 7/8 (88%) was achieved, there was local recurrence in four of these seven patients. Both of the retromolar trigon tumors showed marginal recurrence. No serious (e.g., ulcer or bone exposure) late radiation damage has been observed thus far in the follow up period of 15-57 months. High-dose-rate brachytherapy using the mold technique seems a safe and useful method for selected early and superficial oral cavity cancer. However, it is not indicated for thick tumors and/or tumors located in the retromolar trigon. (author)

  10. Update on pediatric resuscitation drugs: high dose, low dose, or no dose at all.

    Science.gov (United States)

    Sorrentino, Annalise

    2005-04-01

    Pediatric resuscitation has been a topic of discussion for years. It is difficult to keep abreast of changing recommendations, especially for busy pediatricians who do not regularly use these skills. This review will focus on the most recent guidelines for resuscitation drugs. Three specific questions will be discussed: standard dose versus high-dose epinephrine, amiodarone use, and the future of vasopressin in pediatric resuscitation. The issue of using high-dose epinephrine for cardiopulmonary resuscitation refractory to standard dose epinephrine has been a topic of debate for many years. Recently, a prospective, double-blinded study was performed to help settle the debate. These results will be reviewed and compared with previous studies. Amiodarone is a medication that was added to the pediatric resuscitation algorithms with the most recent recommendations from the American Heart Association in 2000. Its use and safety will also be discussed. Another topic that is resurfacing in resuscitation is the use of vasopressin. Its mechanism and comparisons to other agents will be highlighted, although its use in the pediatric patient has not been thoroughly studied. Pediatric resuscitation is a constantly evolving subject that is on the mind of anyone taking care of sick children. Clinicians are continually searching for the most effective methods to resuscitate children in terms of short- and long-term outcomes. It is important to be familiar with not only the agents being used but also the optimal way to use them.

  11. Primary treatment of acromegaly with high-dose lanreotide: a case series

    Directory of Open Access Journals (Sweden)

    Cordes Uwe

    2010-03-01

    Full Text Available Abstract Introduction The first-line treatment for acromegaly is transsphenoidal surgery. In approximately 50% of patients, however, a cure is not possible with surgery and alternatives are needed. Somatostatin analog therapy is the recommended first-line treatment in patients with such cases. Here we provide the first report of a high-dose lanreotide primary therapy in patients with acromegaly. Case presentation Six patients who were not suitable for surgery were given 60 mg of lanreotide (Autogel® every four weeks. All patients were German nationals and Caucasian. When the response of our patients was unsatisfactory, the dose was increased sequentially to 90 mg every four weeks, 120 mg every four weeks, 120 mg every three weeks and 180 mg every three weeks. Treatment duration was 12 to 24 months. In all cases, the lanreotide dose was 120 mg every 4 weeks or higher. In five of our patients, growth hormone (GH levels were successfully reduced (in three patients GH Tumor shrinkage or degeneration was observed in the five responding patients. No drug-related adverse events were noted. Conclusions These results suggest that lanreotide at high doses of 120 mg every four weeks or more is an effective first-line therapy for patients with acromegaly that surgery alone cannot treat.

  12. Preoperative High-Dose Steroid Has Long-Term Beneficial Effects for Myasthenia Gravis

    Directory of Open Access Journals (Sweden)

    Syuichi Tetsuka

    2013-01-01

    Full Text Available Previous studies addressing preoperative steroid treatment have revealed that control of myasthenia gravis (MG with steroids prior to surgery appeared to stabilize postoperative status. The purpose of our study was to clarify the clinical benefits of the preoperative programmed high-dose steroid treatment on the long-term outcomes of MG patients. We retrospectively reviewed the records of 171 MG patients who were followed up after undergoing thymectomy in our hospital between 1988 and 2006. One hundred and thirteen patients in the programmed treatment group had received preoperative steroid treatment, while 58 patients received no steroid treatment during the preoperative period. Clinical remission, which was defined as the achievement of the modified pharmacologic remission (PR for at least 1 year, and clinical benefits were compared between the two groups. With regard to the remission after thymectomy, Kaplan-Meier life-table curves for patients in the preoperative steroid treatment group versus those for patients in the no steroid preoperative treatment group revealed a significantly higher probability of the PR in the preoperative steroid treatment group (log-rank test, P<0.01. This study might be the first, as per our knowledge, to indicate that preoperative programmed high-dose steroid treatment has long-term beneficial effects for MG patients.

  13. Acute Changes in Mentation in a Patient with Hepatic Cirrhosis Treated with High Doses of Dexamethasone.

    Science.gov (United States)

    Dabul, Luis; Droney, Andrew; Oms, Juan; Sanchez-Gonzalez, Marcos A

    2017-09-10

    Despite the anti-inflammatory benefits of steroids in the management of multiple medical conditions, they are associated with undesired metabolic and psychiatric side effects. We present a case of a 57-year-old Hispanic man with hepatic cirrhosis due to hepatitis C and no past medical history of psychiatric illnesses who became delirious after treatment with high doses of intravenous Dexamethasone. The patient presented to Larkin Community Hospital, USA with complaints of lower back pain requiring treatment with steroids for severe lumbar central canal stenosis. After three days of treatment, the patient became disoriented to time and place, grossly psychotic with auditory hallucinations and disorganized behavior, manic, aggressive, combative, restless, hard to redirect, and unable to follow commands. He met the criteria for a diagnosis of substance-induced psychotic disorder according to Diagnostic and Statistical Manual of Mental Disorders (DSM) V. Furthermore, the patient had worsening hepatic profile, a high ammonia level of 125 umol/L, and clinical findings consistent with West Haven classification grade 2 encephalopathy. Head computed tomography (CT) scan was normal. He was treated with discontinuation of steroids, lactulose, and Haloperidol returning to baseline mental status after 48 hours. The patient's hospitalization was complicated with a prolonged hospital stay after lumbar surgery. This case illustrates that treatment with high doses of Dexamethasone in a patient with hepatic cirrhosis can cause acute changes in mental status by (i) inducing delirium, and (ii) precipitating hepatic encephalopathy.

  14. Dosimetric properties of bio minerals applied to high-dose dosimetry using the TSEE technique

    Energy Technology Data Exchange (ETDEWEB)

    Vila, G. B.; Caldas, L. V. E., E-mail: gbvila@ipen.br [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The study of the dosimetric properties such as reproducibility, the residual signal, lower detection dose, dose-response curve and fading of the thermally stimulated emission exo electronic (TSEE) signal of Brazilian bio minerals has shown that these materials present a potential use as radiation dosimeters. The reproducibility within ± 10% for oyster shell, mother-of-pearl and coral reef samples showed that the signal dispersion is small when compared with the mean value of the measurements. The study showed that the residual signal can be eliminated with a thermal treatment at 300 grades C/1 h. The lower detection dose of 9.8 Gy determined for the oyster shell samples when exposed to beta radiation and 1.6 Gy for oyster shell and mother-of-pearl samples when exposed to gamma radiation can be considered good, taking into account the high doses of this study. The materials presented linearity at the dose response curves in some ranges, but the lack of linearity in other cases presents no problem since a good mathematical description is possible. The fading study showed that the loss of TSEE signal can be minimized if the samples are protected from interferences such as light, heat and humidity. Taking into account the useful linearity range as the main dosimetric characteristic, the tiger shell and oyster shell samples are the most suitable for high-dose dosimetry using the TSEE technique. (Author)

  15. Can high-dose fotemustine reverse MGMT resistance in glioblastoma multiforme?

    Science.gov (United States)

    Gallo, Chiara; Buonerba, Carlo; Di Lorenzo, Giuseppe; Romeo, Valeria; De Placido, Sabino; Marinelli, Alfredo

    2010-11-01

    Glioblastoma multiforme (GBM), the highest grade malignant glioma, is associated with a grim prognosis-median overall survival is in the range 12-15 months, despite optimum treatment. Surgery to the maximum possible extent, external beam radiotherapy, and systemic temozolomide chemotherapy are current standard treatments for newly diagnosed GBM, with intracerebral delivery of carmustine wafers (Gliadel). Unfortunately, the effectiveness of chemotherapy can be hampered by the DNA repair enzyme O6-methylguanine methyltransferase (MGMT), which confers resistance both to temozolomide and nitrosoureas, for example fotemustine and carmustine. MGMT activity can be measured by PCR and immunohistochemistry, with the former being the current validated technique. High-dose chemotherapy can deplete MGMT levels in GBM cells and has proved feasible in various trials on temozolomide, in both newly diagnosed and recurrent GBM. We here report the unique case of a GBM patient, with high MGMT expression by immunohistochemistry, who underwent an experimental, high-dose fotemustine schedule after surgery and radiotherapy. Although treatment caused two episodes of grade 3-4 thrombocytopenia, a complete response and survival of more than three years were achieved, with a 30% increase in dose intensity compared with the standard fotemustine schedule.

  16. Medical and Psychiatric Effects of Long-Term Dependence on High Dose of tramadol.

    Science.gov (United States)

    El-Hadidy, Mohmed Adel; Helaly, Ahmed Mohamed Nabil

    2015-04-01

    Tramadol dependence has been studied recently after large-scale exposure. Although tramadol dependence has increased rapidly in Egypt since 2004, no studies have evaluated the effect of high dose long-term tramadol dependence. To address the chronic sequel of tramadol dependence over at least 5 years duration with a large dose (more than 675 mg/day, three tablets or more, each tablet of 225 mg). The study was aimed to check the physical and psychiatric status during tramadol dependence and 3 months after complete treatment. The present study was applied on 79 patients with single tramadol-dependence dose of 675 mg or more for 5 years or more. We examined the physical and psychological impact of tramadol abuse before and after 3 months of stoppage of the drug. The blood chemistry was nearly within normal parameters, although slight nonsignificant rise in liver enzymes was reported in some cases. Patients during tramadol dependence period were angry, hostile, and aggressive. On the other hand, after treatment the main problem observed was the significant increase in comorbid anxiety, depressive, and obsessive-compulsive symptoms, but no increase was found in psychotic symptoms. Tramadol-dependence dose was more important than duration of use in psychiatric illness. Tramadol dependence on high dose could be physically safe to some limit, but psychiatrically it has many side effects.

  17. Definitive intraoperative very high-dose radiotherapy for localized osteosarcoma in the extremities

    International Nuclear Information System (INIS)

    Oya, Natsuo; Kokubo, Masaki; Mizowaki, Takashi; Shibamoto, Yuta; Nagata, Yasushi; Sasai, Keisuke; Nishimura, Yasumasa; Tsuboyama, Tadao; Toguchida, Junya; Nakamura, Takashi; Hiraoka, Masahiro

    2001-01-01

    Purpose: To evaluate the outcome and adverse effects in patients with osteosarcoma treated with very high-dose definitive intraoperative radiotherapy (IORT), with the intention of saving the affected limb. Methods and Materials: Thirty-nine patients with osteosarcoma in their extremities were treated with definitive IORT. The irradiation field included the tumor plus an adequate wide margin and excluded the major vessels and nerves. Forty-five to 80 Gy of electrons or X-rays were delivered. The median follow-up of the surviving patients was 124 months. Results: The cause-specific and relapse-free 5-year survival rate was 50% and 43%, respectively. Distant metastasis developed in 23 patients; 19 died and 4 were alive for >10 years. Nine local recurrences were found 4-29 months after IORT in the affected limb. No radiation-induced skin reaction or nerve palsy was observed in the patients treated with X-rays. Experiments using phantoms also confirmed that the scatter dose was below the toxic level in the IORT setting with X-rays. Conclusions: Very high-dose definitive IORT combined with preventive nailing and chemotherapy appeared to be a promising quality-of-life-oriented alternative to treating patients with osteosarcomas in the extremities, although the problem of recurrences from the surrounding unirradiated soft tissue remains to be solved

  18. High-Dose Radioiodine Outpatient Treatment: An Initial Experience in Thailand

    International Nuclear Information System (INIS)

    Nantajit, Danupon; Saengsuda, Sureerat; NaNakorn, Pattama; Saengsuda, Yuthana

    2015-01-01

    The aim of this study was to determine whether high-dose radioactive iodine (Na 131 I) outpatient treatment of patients with thyroid carcinoma is a pragmatically safe approach, particularly for the safety of caregivers. A total of 79 patients completed the radiation-safety questionnaires prior to receiving high-dose radioactive iodine treatment. The questionnaire studied the subjects’ willingness to be treated as outpatients, along with the radiation safety status of their caregivers and family members. In patients, who were selected to be treated as outpatients, both internal and external radiation exposures of their primary caregivers were measured, using thyroid uptake system and electronic dosimeter, respectively. Overall, 62 out of 79 patients were willing to be treated as outpatients; however, only 44 cases were eligible for the treatment. The primary reason was that the patients did not use exclusive, separated bathrooms. The caregivers of 10 subjects, treated as outpatients, received an average radiation dose of 138.1 microsievert (mSv), which was almost entirely from external exposure; the internal radiation exposures were mostly at negligible values. Therefore, radiation exposure to caregivers was significantly below the public exposure limit (1 mSv) and the recommended limit for caregivers (5 mSv). A safe 131 I outpatient treatment in patients with thyroid carcinoma could be achieved by selective screening and providing instructions for patients and their caregivers

  19. Fatal Gastrointestinal Hemorrhage in a Young Boy with Newly Diagnosed Metastatic Medulloblastoma on High Dose Dexamethasone

    Directory of Open Access Journals (Sweden)

    Victor Wong

    2014-01-01

    Full Text Available A 10-year-old boy with newly diagnosed metastatic medulloblastoma was placed on high dose dexamethasone and ranitidine prior to surgery. The child underwent subtotal resection and was discharged 5 days postoperatively with an uneventful hospital course on a tapering dose of dexamethasone and ranitidine. Over the next 2 days the patient complained of mild abdominal distension with flatulence, without pain, vomiting, or dysmotility. On follow-up in clinic 5 days after discharge, he had normal vital signs when he suddenly became pale and had loss of consciousness. Emergent computerized tomography of the head showed no acute hemorrhage and complete blood count revealed hemoglobin of 4.2 gm/dL. In spite of maximum resuscitation with copious blood products the patient died. Autopsy revealed evidence of duodenal perforation with intraluminal hemorrhage. This case demonstrates a rare fatal complication of high dose dexamethasone therapy even with concurrent gastrointestinal prophylactic therapy. We provide a review of the limited literature on steroid use in pediatric neurooncology with regard to gastrointestinal bleeding.

  20. Thermoacoustic refrigerators and engines comprising cascading stirling thermodynamic units

    Science.gov (United States)

    Backhaus, Scott; Swift, Greg

    2013-06-25

    The present invention includes a thermoacoustic assembly and method for improved efficiency. The assembly has a first stage Stirling thermal unit comprising a main ambient heat exchanger, a regenerator and at least one additional heat exchanger. The first stage Stirling thermal unit is serially coupled to a first end of a quarter wavelength long coupling tube. A second stage Stirling thermal unit comprising a main ambient heat exchanger, a regenerator, and at least one additional heat exchanger, is serially coupled to a second end of the quarter wavelength long coupling tube.

  1. Safety of high-dose daptomycin in patients with severe renal impairment

    Directory of Open Access Journals (Sweden)

    Tai CH

    2018-03-01

    Full Text Available Chih-Hsun Tai,1 Chi-Hao Shao,2 Chen-You Chen,2 Shu-Wen Lin,1–3 Chien-Chih Wu1,2 1Department of Pharmacy, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan; 2School of Pharmacy, College of Medicine, National Taiwan University, Taipei, Taiwan; 3Graduate Institute of Clinical Pharmacy, College of Medicine, National Taiwan University, Taipei, Taiwan Background: Treatment options are limited for infections due to multidrug-resistant Gram-positive pathogens. Daptomycin is a lipopeptide antibiotic with concentration-dependent killing characteristic and dose-dependent post-antibiotic effect. To achieve optimized pharmacodynamic effect, some experts advocated using a high dose of daptomycin (≥9 mg/kg for severe infections. However, the safety of high-dose therapy in patients with renal impairment remains unknown. This study was aimed to evaluate the safety of daptomycin in patients with severe renal impairment. Methods: This was a retrospective study performed by reviewing electronic medical records. Patients with severe renal impairment who were treated with daptomycin in a tertiary teaching hospital between January 1, 2013, and June 30, 2016, were included for evaluation. The incidence rates of creatine kinase (CK elevation between high-dose (≥9 mg/kg and standard-dose (<9 mg/kg groups were compared. Results: Overall, 164 patients met the inclusion criteria, and 114 (69.5% of them were on renal replacement therapy. Vancomycin-resistant enterococci were the most common pathogens (61.3% of the patients with documented pathogens. The treatment success rate was 51.6% in the 91 patients with bacteremia. The average dose of daptomycin was 8.0±2.3 mg/kg, and 37 (22.6% patients received ≥9 mg/kg. CK levels were followed in 108 (65.9% patients. Significantly higher incidence of CK elevation was found in the high-dose group compared with that in the standard-dose group (10.8% vs 1.6%, P<0.05. Moreover

  2. Effects of intensive induction and consolidation chemotherapy with idarubicin and high dose cytarabine on minimal residual disease levels in newly diagnosed adult precursor-B acute lymphoblastic leukemia

    Directory of Open Access Journals (Sweden)

    Kenneth F. Bradstock

    2016-12-01

    Full Text Available An intensive induction regimen, consisting of idarubicin and high dose cytarabine, was assessed in 19 adult patients, median age 44 years, with newly diagnosed precursor-B acute lymphoblastic leukemia (ALL. Patients achieving a complete response (CR were given an attenuated consolidation course. The primary endpoints were induction death rate and incidence of serious non-hematological toxicity. Grades 3–4 diarrhoea occurred in 47% of patients during induction. Two patients (11% died during induction therapy, and 2 were withdrawn due to resistant disease or prolonged marrow hypoplasia. Fifteen patients achieved CR (79%, but levels of minimal residual disease (MRD after induction were comparable with those previously observed using a modified pediatric protocol. Overall survival at 5 years was 36.8% while leukemia-free survival was 44.1%. An intensive AML protocol used in adults with ALL resulted in substantial toxicity and provided similar levels of cytoreduction to conventional ALL protocols, without improving long-term outcomes.

  3. Effect of time to infusion of autologous stem cells (24 vs. 48 h) after high-dose melphalan in patients with multiple myeloma.

    Science.gov (United States)

    Talamo, Giampaolo; Rakszawski, Kevin L; Rybka, Witold B; Dolloff, Nathan G; Malysz, Jozef; Berno, Tamara; Zangari, Maurizio

    2012-08-01

    High-dose melphalan (HD-Mel) is considered the current standard of care among the preparative regimens used in autologous peripheral blood stem cell transplantation (SCT) for multiple myeloma (MM), but optimal time and schedule of administration is not defined. We retrospectively analyzed outcomes and toxicities of HD-Mel administered on day -2 vs. day -1 before autologous stem cells infusion. A total of 138 consecutive MM patients treated at Penn State Hershey Cancer Institute between 2007 and 2010 were included in this study. No difference in time to hematopoietic recovery, common SCT-related toxicities, and clinical outcomes was seen between patients who received HD-Mel on day -2 (group A, n = 47), and those who received it on day -1 (group B, n = 91). Prompt and full hematopoietic recovery occurred even when stem cells were infused between 8 and 24 h after completion of chemotherapy. In the absence of prospective and randomized data, we conclude that a single I.V. infusion of HD-Mel on day -1 is a safe and effective practice, and the so-called 'day of rest' before the transplant appears not to be necessary. © 2012 John Wiley & Sons A/S.

  4. DC-to-DC converter comprising a reconfigurable capacitor unit

    NARCIS (Netherlands)

    2008-01-01

    The present invention relates to a configurable trench multi-capacitor device comprising a trench in a semiconductor substrate. The trench has a lateral extension exceeding 10 micrometer and a trench filling includes a number of at least four electrically conductive capacitor-electrode layers. A

  5. Hot gas handling device and motorized vehicle comprising the device

    NARCIS (Netherlands)

    Klein Geltink, J.; Beukers, A.; Van Tooren, M.J.L.; Koussios, S.

    2012-01-01

    The invention relates to a device for handling hot exhaust gasses discharged from an internal combustion engine. The device comprises a housing (2), enclosing a space (3) for transporting the exhaust gasses. The housing (2) is provided with an entrance - opening (4) for the exhaust gasses discharged

  6. Non-cementitious compositions comprising vaterite and methods thereof

    Science.gov (United States)

    Devenney, Martin; Fernandez, Miguel; Morgan, Samuel O.

    2015-09-15

    Non-cementitious compositions and products are provided. The compositions of the invention include a carbonate additive comprising vaterite such as reactive vaterite. Additional aspects of the invention include methods of making and using the non-cementitious compositions and products.

  7. DC-to-DC converter comprising a reconfigurable capacitor unit

    NARCIS (Netherlands)

    Klootwijk, J.H.; Bergveld, H.J.; Roozeboom, F.; Reefman, D.; Ruigrok, J.

    2013-01-01

    The present invention relates to a configurable trench multi-capacitor device comprising a trench in a semiconductor substrate. The trench has a lateral extension exceeding 10 micrometer and a trench filling includes a number of at least four electrically conductive capacitor-electrode layers. A

  8. Cumulative high doses of inhaled formoterol have less systemic effects in asthmatic children 6-11 years-old than cumulative high doses of inhaled terbutaline.

    Science.gov (United States)

    Kaae, Rikke; Agertoft, Lone; Pedersen, Sören; Nordvall, S Lennart; Pedroletti, Christophe; Bengtsson, Thomas; Johannes-Hellberg, Ingegerd; Rosenborg, Johan

    2004-10-01

    To evaluate high dose tolerability and relative systemic dose potency between inhaled clinically equipotent dose increments of formoterol and terbutaline in children. Twenty boys and girls (6-11 years-old) with asthma and normal ECGs were studied. Ten doses of formoterol (Oxis) 4.5 microg (F4.5) or terbutaline (Bricanyl) 500 microg (T500) were inhaled cumulatively via a dry powder inhaler (Turbuhaler) over 1 h (three patients) or 2.5 h (17 patients) and compared to a day of no treatment, in a randomised, double-blind (active treatments only), crossover trial. Blood pressure (BP), ECG, plasma potassium, glucose, lactate, and adverse events were monitored up to 10 h to assess tolerability and relative systemic dose potency. Formoterol and terbutaline had significant beta2-adrenergic effects on most outcomes. Apart from the effect on systolic BP, QRS duration and PR interval, the systemic effects were significantly more pronounced with terbutaline than with formoterol. Thus, mean minimum plasma potassium, was suppressed from 3.56 (95% confidence interval, CI: 3.48-3.65) mmol l(-1) on the day of no treatment to 2.98 (CI: 2.90-3.08) after 10 x F4.5 and 2.70 (CI: 2.61-2.78) mmol l(-1) after 10 x T500, and maximum Q-Tc (heart rate corrected Q-T interval [Bazett's formula]) was prolonged from 429 (CI: 422-435) ms on the day of no treatment, to 455 (CI: 448-462) ms after 10 x F4.5 and 470 (CI: 463-476) ms after 10 x T500. Estimates of relative dose potency indicated that F4.5 microg had the same systemic activity as the clinically less effective dose of 250 microg terbutaline. The duration of systemic effects differed marginally between treatments. Spontaneously reported adverse events (most frequently tremor) were fewer with formoterol (78% of the children) than with terbutaline (95%). A serious adverse event occurred after inhalation of 45 microg formoterol over the 1 h dosing time, that prompted the extension of dosing time to 2.5 h. Multiple inhalations over 2.5 h of

  9. Cumulative high doses of inhaled formoterol have less systemic effects in asthmatic children 6–11 years-old than cumulative high doses of inhaled terbutaline

    Science.gov (United States)

    Kaae, Rikke; Agertoft, Lone; Pedersen, Sören; Nordvall, S Lennart; Pedroletti, Christophe; Bengtsson, Thomas; Johannes-Hellberg, Ingegerd; Rosenborg, Johan

    2004-01-01

    Objectives To evaluate high dose tolerability and relative systemic dose potency between inhaled clinically equipotent dose increments of formoterol and terbutaline in children. Methods Twenty boys and girls (6–11 years-old) with asthma and normal ECGs were studied. Ten doses of formoterol (Oxis®) 4.5 µg (F4.5) or terbutaline (Bricanyl®) 500 µg (T500) were inhaled cumulatively via a dry powder inhaler (Turbuhaler®) over 1 h (three patients) or 2.5 h (17 patients) and compared to a day of no treatment, in a randomised, double-blind (active treatments only), crossover trial. Blood pressure (BP), ECG, plasma potassium, glucose, lactate, and adverse events were monitored up to 10 h to assess tolerability and relative systemic dose potency. Results Formoterol and terbutaline had significant β2-adrenergic effects on most outcomes. Apart from the effect on systolic BP, QRS duration and PR interval, the systemic effects were significantly more pronounced with terbutaline than with formoterol. Thus, mean minimum plasma potassium, was suppressed from 3.56 (95% confidence interval, CI: 3.48–3.65) mmol l−1 on the day of no treatment to 2.98 (CI: 2.90–3.08) after 10 × F4.5 and 2.70 (CI: 2.61–2.78) mmol l−1 after 10 × T500, and maximum Q-Tc (heart rate corrected Q-T interval [Bazett's formula]) was prolonged from 429 (CI: 422–435) ms on the day of no treatment, to 455 (CI: 448–462) ms after 10 × F4.5 and 470 (CI: 463–476) ms after 10 × T500. Estimates of relative dose potency indicated that F4.5 µg had the same systemic activity as the clinically less effective dose of 250 µg terbutaline. The duration of systemic effects differed marginally between treatments. Spontaneously reported adverse events (most frequently tremor) were fewer with formoterol (78% of the children) than with terbutaline (95%). A serious adverse event occurred after inhalation of 45 µg formoterol over the 1 h dosing time, that prompted the extension of dosing time to 2.5 h

  10. Relationship between irreversible alopecia and exposure to cyclophosphamide, thiotepa and carboplatin (CTC) in high-dose chemotherapy

    NARCIS (Netherlands)

    de Jonge, M. E.; Mathôt, R. A. A.; Dalesio, O.; Huitema, A. D. R.; Rodenhuis, S.; Beijnen, J. H.

    2002-01-01

    Reversible alopecia is a commonly observed, important and distressing complication of chemotherapy. Permanent alopecia, however, is rare after standard-dose therapy, but has occasionally been observed after high-dose chemotherapy with cyclophosphamide, thiotepa and carboplatin (CTC). We evaluated

  11. Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Bhavana [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Patel, Firuza D., E-mail: firuzapatel@gmail.com [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Chakraborty, Santam; Sharma, Suresh C.; Kapoor, Rakesh [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Aprem, Abi Santhosh [Corporate R and D Division, HLL Lifecare Limited, Karamana, Trivandrum (India)

    2013-04-01

    Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the second application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of

  12. Five-Year Outcomes of High-Dose Single-Fraction Spinal Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Moussazadeh, Nelson; Lis, Eric; Katsoulakis, Evangelia; Kahn, Sweena; Svoboda, Marek; DiStefano, Natalie M.; McLaughlin, Lily; Bilsky, Mark H.; Yamada, Yoshiya; Laufer, Ilya

    2015-01-01

    Purpose: To characterize local tumor control and toxicity risk in very long-term survivors (>5 years) after high-dose spinal image guided, intensity modulated radiation therapy delivered as single-dose stereotactic radiosurgery (SRS). Previously published spinal SRS outcome analyses have included a heterogeneous population of cancer patients, mostly with short survival. This is the first study reporting the long-term tumor control and toxicity profiles after high-dose single-fraction spinal SRS. Methods and Materials: The study population included all patients treated from June 2004 to July 2009 with single-fraction spinal SRS (dose 24 Gy) who had survived at least 5 years after treatment. The endpoints examined included disease progression, surgical or radiation retreatment, in-field fracture development, and radiation-associated toxicity, scored using the Radiation Therapy Oncology Group radiation morbidity scoring criteria and the Common Terminology Criteria for Adverse Events, version 4.0. Local control and fracture development were assessed using Kaplan-Meier analysis. Results: Of 278 patients, 31 (11.1%), with 36 segments treated for spinal tumors, survived at least 5 years after treatment and were followed up radiographically and clinically for a median of 6.1 years (maximum 102 months). The histopathologic findings for the 5-year survivors included radiation-resistant metastases in 58%, radiation-sensitive metastases in 22%, and primary bone tumors in 19%. In this selected cohort, 3 treatment failures occurred at a median of 48.6 months, including 2 recurrences in the radiation field and 1 patient with demonstrated progression at the treatment margins. Ten lesions (27.8%) were associated with acute grade 1 cutaneous or gastrointestinal toxicity. Delayed toxicity ≥3 months after treatment included 8 cases (22.2%) of mild neuropathy, 2 (5.6%) of gastrointestinal discomfort, 8 (22.2%) of dermatitides, and 3 (8.3%) of myalgias/myositis. Thirteen

  13. Chromosomal Aberrations in Normal and AT Cells Exposed to High Dose of Low Dose Rate Irradiation

    Science.gov (United States)

    Kawata, T.; Shigematsu, N.; Kawaguchi, O.; Liu, C.; Furusawa, Y.; Hirayama, R.; George, K.; Cucinotta, F.

    2011-01-01

    Ataxia telangiectasia (A-T) is a human autosomally recessive syndrome characterized by cerebellar ataxia, telangiectases, immune dysfunction, and genomic instability, and high rate of cancer incidence. A-T cell lines are abnormally sensitive to agents that induce DNA double strand breaks, including ionizing radiation. The diverse clinical features in individuals affected by A-T and the complex cellular phenotypes are all linked to the functional inactivation of a single gene (AT mutated). It is well known that cells deficient in ATM show increased yields of both simple and complex chromosomal aberrations after high-dose-rate irradiation, but, less is known on how cells respond to low-dose-rate irradiation. It has been shown that AT cells contain a large number of unrejoined breaks after both low-dose-rate irradiation and high-dose-rate irradiation, however sensitivity for chromosomal aberrations at low-dose-rate are less often studied. To study how AT cells respond to low-dose-rate irradiation, we exposed confluent normal and AT fibroblast cells to up to 3 Gy of gamma-irradiation at a dose rate of 0.5 Gy/day and analyzed chromosomal aberrations in G0 using fusion PCC (Premature Chromosomal Condensation) technique. Giemsa staining showed that 1 Gy induces around 0.36 unrejoined fragments per cell in normal cells and around 1.35 fragments in AT cells, whereas 3Gy induces around 0.65 fragments in normal cells and around 3.3 fragments in AT cells. This result indicates that AT cells can rejoin breaks less effectively in G0 phase of the cell cycle? compared to normal cells. We also analyzed chromosomal exchanges in normal and AT cells after exposure to 3 Gy of low-dose-rate rays using a combination of G0 PCC and FISH techniques. Misrejoining was detected in the AT cells only? When cells irradiated with 3 Gy were subcultured and G2 chromosomal aberrations were analyzed using calyculin-A induced PCC technique, the yield of unrejoined breaks decreased in both normal and AT

  14. Effect of Concurrent High-Dose Cisplatin Chemotherapy and Conformal Radiotherapy on Cervical Esophageal Cancer Survival

    International Nuclear Information System (INIS)

    Huang Shaohui; Lockwood, Gina; Brierley, James; Cummings, Bernard; Kim, John; Wong, Rebecca; Bayley, Andrew; Ringash, Jolie

    2008-01-01

    Purpose: To determine whether a change in treatment policy to conformal, elective nodal radiotherapy and concurrent high-dose cisplatin improved survival for cervical esophageal cancer patients. Methods and Materials: All cervical esophageal cancer patients treated between 1997 and 2005 were restaged (1983 American Joint Committee on Cancer criteria). Patients treated before 2001 (previous cohort [PC]) were compared with those treated from 2001 onward (recent cohort [RC]). The PC institutional chemoradiotherapy protocol was 54 Gy in 20 fractions within 4 weeks, with 5-fluorouracil (1,000 mg/m 2 ) on Days 1-4 and either mitomycin C (10 mg/m 2 ) or cisplatin (75 mg/m 2 ) on Day 1. The RC institutional chemoradiotherapy protocol was conformal radiotherapy, 70 Gy in 35 fractions within 7 weeks, to the primary tumor and elective nodes, with high-dose cisplatin (100 mg/m 2 ) on Days 1, 22, and 43. Results: The median follow-up was 3.1 years (PC, 8.1 and RC, 2.3). Of 71 patients (25 women and 46 men), 21 of 29 in the PC and 29 of 42 in the RC were treated curatively (curative subgroup, n = 50). Between the two groups, no differences in overall survival or locoregional relapse-free survival were seen. The overall survival rate at 2 and 5 years was 35% (range, 24-47%) and 21% (range, 12-32%) in the whole group and 46% (range 32-60%) and 28% (range, 15-42%) in the curative group, respectively. In the curative group, no statistically significant prognostic factors were found. Trends toward better locoregional relapse-free survival were seen in women (2-year rate, 73% vs. for men, 36%; p = 0.08) and in patients aged >64 years (2-year rate, 68% vs. age ≤64 years, 34%; p = 0.10). Conclusion: No survival improvement could be demonstrated after changing the treatment policy to high-dose cisplatin-based, conventionally fractionated conformal chemoradiotherapy. Female gender and older age might predict for better outcomes

  15. Prospective study in the management of high-dose radioactive iodine therapy induced gastritis

    International Nuclear Information System (INIS)

    Carbonell, C.; Ogbac, R.V.

    2007-01-01

    Full text: Gastritis is simply defined as inflammation of the gastric mucosa. In post-RAI patients, this is one of the most common complications that are encountered. Some patients may even require repetitive administration of high doses of radioactive iodine (I-131). Small doses of radiation (up to 1500 R) cause reversible mucosal damage, whereas higher radiation doses cause irreversible damage with atrophy and ischemic-related ulceration. Reversible changes consist of degenerative changes in epithelial cells and nonspecific chronic inflammatory infiltrate in the lamina propria. Higher amounts of radiation cause permanent mucosal damage, with atrophy of fundic glands, mucosal erosions, and capillary hemorrhage. Associated submucosal endarteritis results in mucosal ischemia and secondary ulcer development. Recurrent gastritis, if left untreated, may be a predisposing factor for gastric malignancy. Methods:A total of thirty post-RAI subjects were evaluated for signs and symptoms of gastritis and were divided into 3 groups which were given drugs for gastritis (H2-receptor antagonist, proton pump inhibitor, and sucralfate). Survey forms were distributed to evaluate the presence of nausea, vomiting, epigastric pain (graded according to severity of pain), and gastrointestinal bleeding. Results were tallied accordingly. Results and Discussion: In a total of 3 subjects who were given sucralfate, all of them did not experience any nausea and vomiting. One subject experienced mild epigastric discomfort and another subject was able to experience a non-specific symptom of abdominal bloatedness. (Note: Subjects are still for completion) In theory, radiation irritates the mucosa causing inflammation and mucosal damage which is further irritated by gastric acid secretion. The administration of H2-receptor blockers and proton pump inhibitors only inhibit gastric acid secretion while existing inflammation of mucosa due to high doses of radiation is left untreated. However

  16. Five-Year Outcomes of High-Dose Single-Fraction Spinal Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Moussazadeh, Nelson [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Lis, Eric [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Katsoulakis, Evangelia [Department of Radiation Oncology, New York Methodist Hospital, Brooklyn, New York (United States); Kahn, Sweena; Svoboda, Marek; DiStefano, Natalie M.; McLaughlin, Lily [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Bilsky, Mark H. [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Yamada, Yoshiya [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Laufer, Ilya, E-mail: lauferi@mskcc.org [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States)

    2015-10-01

    Purpose: To characterize local tumor control and toxicity risk in very long-term survivors (>5 years) after high-dose spinal image guided, intensity modulated radiation therapy delivered as single-dose stereotactic radiosurgery (SRS). Previously published spinal SRS outcome analyses have included a heterogeneous population of cancer patients, mostly with short survival. This is the first study reporting the long-term tumor control and toxicity profiles after high-dose single-fraction spinal SRS. Methods and Materials: The study population included all patients treated from June 2004 to July 2009 with single-fraction spinal SRS (dose 24 Gy) who had survived at least 5 years after treatment. The endpoints examined included disease progression, surgical or radiation retreatment, in-field fracture development, and radiation-associated toxicity, scored using the Radiation Therapy Oncology Group radiation morbidity scoring criteria and the Common Terminology Criteria for Adverse Events, version 4.0. Local control and fracture development were assessed using Kaplan-Meier analysis. Results: Of 278 patients, 31 (11.1%), with 36 segments treated for spinal tumors, survived at least 5 years after treatment and were followed up radiographically and clinically for a median of 6.1 years (maximum 102 months). The histopathologic findings for the 5-year survivors included radiation-resistant metastases in 58%, radiation-sensitive metastases in 22%, and primary bone tumors in 19%. In this selected cohort, 3 treatment failures occurred at a median of 48.6 months, including 2 recurrences in the radiation field and 1 patient with demonstrated progression at the treatment margins. Ten lesions (27.8%) were associated with acute grade 1 cutaneous or gastrointestinal toxicity. Delayed toxicity ≥3 months after treatment included 8 cases (22.2%) of mild neuropathy, 2 (5.6%) of gastrointestinal discomfort, 8 (22.2%) of dermatitides, and 3 (8.3%) of myalgias/myositis. Thirteen

  17. High-Dose Opioid Prescribing and Opioid-Related Hospitalization: A Population-Based Study.

    Directory of Open Access Journals (Sweden)

    Kimberly Fernandes

    Full Text Available To examine the impact of national clinical practice guidelines and provincial drug policy interventions on prevalence of high-dose opioid prescribing and rates of hospitalization for opioid toxicity.Interventional time-series analysis.Ontario, Canada, from 2003 to 2014.Ontario Drug Benefit (ODB beneficiaries aged 15 to 64 years from 2003 to 2014.Publication of Canadian clinical practice guidelines for use of opioids in chronic non-cancer pain (May 2010 and implementation of Ontario's Narcotics Safety and Awareness Act (NSAA; November 2011.Three outcomes were explored: the rate of opioid use among ODB beneficiaries, the prevalence of opioid prescriptions exceeding 200 mg and 400 mg morphine equivalents per day, and rates of opioid-related emergency department visits and hospital admissions.Over the 12 year study period, the rate of opioid use declined 15.2%, from 2764 to 2342 users per 10,000 ODB eligible persons. The rate of opioid use was significantly impacted by the Canadian clinical practice guidelines (p-value = .03 which led to a decline in use, but no impact was observed by the enactment of the NSAA (p-value = .43. Among opioid users, the prevalence of high-dose prescribing doubled (from 4.2% to 8.7% over the study period. By 2014, 40.9% of recipients of long-acting opioids exceeded daily doses of 200 mg morphine or equivalent, including 55.8% of long-acting oxycodone users and 76.3% of transdermal fentanyl users. Moreover, in the last period, 18.7% of long-acting opioid users exceeded daily doses of 400 mg morphine or equivalent. Rates of opioid-related emergency department visits and hospital admissions increased 55.0% over the study period from 9.0 to 14.0 per 10,000 ODB beneficiaries from 2003 to 2013. This rate was not significantly impacted by the Canadian clinical practice guidelines (p-value = .68 or enactment of the NSAA (p-value = .59.Although the Canadian clinical practice guidelines for use of opioids in chronic non

  18. High dose rate brachytherapy for carcinoma of the cervix: risk factors for late rectal complications

    International Nuclear Information System (INIS)

    Uno, Takashi; Itami, Jun; Aruga, Moriyo; Kotaka, Kikuo; Fujimoto, Hajime; Minoura, Shigeki

    1996-01-01

    Purpose/Objective: To determine the incidence of late rectal complications in patients treated with high dose rate brachytherapy for FIGO stage IIB, IIIB carcinoma of the uterine cervix, and to evaluate the treatment factors associated with an increased probability of treatment complications. Materials and Methods: Records of 100 patients with FIGO IIB or IIIB cervical carcinoma treated with definitive irradiation using high dose rate intracavitary brachytherapy (HDR-ICR) between 1977 and 1994 were retrospectively reviewed. For each HDR-ICR session, 6 Gy isodose volume was reconstructed three dimensionally and the following three parameters were determined to represent this isodose volume, length (L); maximum longitudinal distance of 6 Gy isodose area in an oblique frontal plane containing the intrauterine applicator, width (W); maximum width of 6 Gy isodose area in the same plane, height (H); maximum dimension of 6 Gy isodose area perpendicular to the intrauterine applicator determined in the oblique sagittal plane. Point P/Q (2 cm ventral/dorsal from the proximal retention point of the intrauterine source) and point R/S (2 cm ventral/dorsal from the midpoint of the ovoid sources) were also defined retrospectively and HDR-ICR dose at these points were calculated. Statistical analyses were performed to determine the treatment factors predictive of late rectal complications. Results: The 5-year cumulative cause-specific disease-free survival rate was 50% for all, 74% for Stage IIB, and 38% for Stage IIIB, with a significant difference between two FIGO Stages (p=0.0004). Of patients treated for both stages, 30% and 36% had experienced moderate to severe (Grade 2-4) complications at 3 and 5 years, respectively. Average H value (p=0.013) and cumulative point S dose by HDR-ICR (p=0.020) were significantly correlated with the incidence of late rectal complications (Student's t-test), whereas these factors did not significantly affect the probability of pelvic control. No

  19. Characterization of High Dose Mn, Fe, and Ni implantation into p-GaN

    CERN Document Server

    Pearton, S J; Thaler, G; Abernathy, C R; Theodoropoulou, N; Hebard, A F; Chu, S N G; Wilson, R G; Zavada, J M; Polyakov, A Y; Osinsky, A V; Norris, P E; Chow, P P; Wowchack, A M; Hove, J M V; Park, Y D

    2002-01-01

    The magnetization of p-GaN or p-AlGaN/GaN superlattices was measured after implantation with high doses (3-5x10 sup 1 sup 6 cm sup - sup 2) of Mn, Fe, or Ni and subsequent annealing at 700-1000 deg. C. The samples showed ferromagnetic contributions below temperatures ranging from 190-250 K for Mn to 45-185 K for Ni and 80-250 K for Fe. The use of superlattices to enhance the hole concentration did not produce any change in ferromagnetic ordering temperature. No secondary phase formation was observed by x-ray diffraction, transmission electron microscopy, or selected area diffraction pattern analysis for the doses we employed.

  20. Low, but not high, dose caffeine is a readily available probe for adenosine actions.

    Science.gov (United States)

    Fredholm, Bertil B; Yang, Jiangning; Wang, Yingqing

    2017-06-01

    Caffeine is very widely used and knowledge of its mode of action can be used to gain an understanding of basal physiological regulation. This review makes the point that caffeine is - in low doses - an antagonist of adenosine acting at A 1 , A 2A and A 2B receptors. We use published and unpublished data to make the point that high dose effects of caffeine are not only qualitatively different but have a different underlying mechanism. Therefore one must be careful in only using epidemiological or experimental data where rather low doses of caffeine are used to draw conclusions about the physiology and pathophysiology of adenosine. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. [Effect of IV hydration with sodium bicarbonate on high-dose methotrexate disposition kinetics].

    Science.gov (United States)

    Tsuda, N; Goto, M; Konishi, H; Yamashina, H

    1984-04-01

    Following two-compartment kinetic analysis, the effect of loading of transfusion with sodium bicarbonate on methotrexate disposition was investigated in 13 cases with malignant tumor, being treated with high-dose methotrexate. The mean values of total body clearance, when administered at doses 50 mg and 100 mg per kg body weight, were 0.369 and 0.402 (l/h) per kg, respectively. No significant relationship was observed between alpha value and total amount of transfusion, of urine or dosage of sodium bicarbonate. The other kinetic parameters on elimination, beta value, K10 and total body clearance, did not also correlate with those values described above. These results suggest that the elimination profile of methotrexate show linear kinetics, and that massive administration of transfusion with sodium bicarbonate be not necessary if pH value of urine exceeds 7.0.

  2. Dosimetric advancement of high-dose-rate after-loading 192Ir source

    International Nuclear Information System (INIS)

    Zhang Shuxu; Li Wenhua; Xu Hairong

    2004-01-01

    High-dose-rate (HDR) 192 Ir source is a nuclide commonly used in the brachytherapy system. The basic dosimetry data of the near source area is usually measured by pin ion chambers or TLD techniques, but these methods have a lower spatial resolution than Electron spin resonance (ESR) dosimetry which has a spatial resolution of 156 μm, and the Monte Carlo photon transport simulations are taken as the golden standard of those measures. The precision in two-dimensional dose distribution measured by GafChromic film is reported to be 1.0%. In vivo dosimetry using TLD during HDR intracavitary after-loading brachytherapy is a good predictor of late rectal complications. The accuracy of magnetic resonance imaging (MRI) Fricke-gel dosimetry for three-dimensional dose distribution is about 2.5% with a spatial resolution of 1.56 mm. The optical computed tomography polymer gel dosimetry has a unique advance than MRI gel dosimetry

  3. Improved Behavior and Neuropsychological Function in Children With ROHHAD After High-Dose Cyclophosphamide.

    Science.gov (United States)

    Jacobson, Lisa A; Rane, Shruti; McReynolds, Lisa J; Steppan, Diana A; Chen, Allen R; Paz-Priel, Ido

    2016-07-01

    Rapid-onset obesity with hypothalamic dysfunction, hypoventilation, and autonomic dysregulation (ROHHAD) is a rare, generally progressive, and potentially fatal syndrome of unclear etiology. The syndrome is characterized by normal development followed by a sudden, rapid hyperphagic weight gain beginning during the preschool period, hypothalamic dysfunction, and central hypoventilation, and is often accompanied by personality changes and developmental regression, leading to substantial morbidity and mortality. We describe 2 children who had symptomatic and neuropsychological improvement after high-dose cyclophosphamide treatment. Our experience supports an autoimmune pathogenesis and provides the first neuropsychological profile of patients with rapid-onset obesity with hypothalamic dysfunction, hypoventilation, and autonomic dysregulation. Copyright © 2016 by the American Academy of Pediatrics.

  4. Long-term high-dose oral morphine in phantom limb pain with no addiction risk

    Directory of Open Access Journals (Sweden)

    Vinod Kumar

    2015-01-01

    Full Text Available Chronic phantom limb pain (PLP is a type of neuropathic pain, which is located in the missing/amputated limb. Phantom pain is difficult to treat as the exact basis of pain mechanism is still unknown. Various methods of treatment for PLP have been described, including pharmacological (NSAIDs, opioids, antiepileptic, antidepressants and non-pharmacological (TENS, sympathectomy, deep brain stimulation and motor cortex stimulation. Opioids are used for the treatment of neuropathic pain and dose of opioid is determined based on its effect and thus there is no defined ceiling dose for opioids. We report a case where a patient receiving high-dose oral morphine for chronic cancer pain did not demonstrate signs of addiction.

  5. Radiation-damage studies, irradiations and high-dose dosimetry for LHC detectors

    CERN Document Server

    Coninckx, F; León-Florián, E; Leutz, H; Schönbacher, Helmut; Sonderegger, P; Tavlet, Marc; Sopko, B; Henschel, H; Schmidt, H U; Boden, A; Bräunig, D; Wulf, F; Cramariuc, R; Ilie, D; Fattibene, P; Onori, S; Miljanic, S; Paic, G; Razen, B; Razem, D; Rendic, D; CERN. Geneva. Detector Research and Development Committee

    1991-01-01

    The proposal is divided into a main project and special projects. The main project consists of a service similar to the one given in the past to accelerator construction projects at CERN (ISR,SPS,LEP) on high-dose dosimetry, material irradiations, irradiations tests, standardization of test procedures and data compilations. Large experience in this field and numerous radiation damage test data of insulating and structural materials are available. The special projects cover three topics which are of specific interest for LHC detector physicists and engineers at CERN and in other high energy physics institutes, namely: Radiation effects in scintillators; Selection of radiation hard optical fibres for data transmission; and Selection and testing of radiation hard electronic components.

  6. Acute effects of high-dose intragastric nicotine on mucosal defense mechanisms

    DEFF Research Database (Denmark)

    Lindell, G; Bukhave, Klaus; Lilja, I

    1997-01-01

    Peptic ulcer disease is overrepresented among smokers; they also heal slowly and relapse frequently. Data are accumulating that smoking is detrimental to gastroduodenal mucosal cytoprotection. This study was designed to assess acute effects of high-dose intragastric nicotine, as it has been shown...... that nicotine is accumulated in gastric juice when smoking, Seven healthy smokers were given nicotine base (6 mg) as tablets, which yielded very high intragastric concentrations and plasma levels comparable to those seen when smoking. In addition to nicotine analysis, concentration levels of prostaglandin E(2......) (PGE(2)), phospholipase A(2) (PLA(2)), and phospholipid classes were measured before and after nicotine administration, Nicotine inhibited PGE(2) levels by 27-81%, whereas PLA(2) and total phospholipids were unaffected. Lysolecithin, a degradation product of the main constituent of gastric surfactant...

  7. High-dose-rate intraoperative radiation therapy: the nuts and bolts of starting a program

    Science.gov (United States)

    Moningi, Shalini; Armour, Elwood P.; Terezakis, Stephanie A.; Efron, Jonathan E.; Gearhart, Susan L.; Bivalacqua, Trinity J.; Kumar, Rachit; Le, Yi; Kien Ng, Sook; Wolfgang, Christopher L.; Zellars, Richard C.; Ellsworth, Susannah G.; Ahuja, Nita

    2014-01-01

    High-dose-rate intraoperative radiation therapy (HDR-IORT) has historically provided effective local control (LC) for patients with unresectable and recurrent tumors. However, IORT is limited to only a few specialized institutions and it can be difficult to initiate an HDR-IORT program. Herein, we provide a brief overview on how to initiate and implement an HDR-IORT program for a selected group of patients with gastrointestinal and pelvic solid tumors using a multidisciplinary approach. Proper administration of HDR-IORT requires institutional support and a joint effort among physics staff, oncologists, surgeons, anesthesiologists, and nurses. In order to determine the true efficacy of IORT for various malignancies, collaboration among institutions with established IORT programs is needed. PMID:24790628

  8. Influence of environmental factors on some high dose dosimeter responses in Yazd Radiation Processing Center

    International Nuclear Information System (INIS)

    Ziaie, F.; Tahami, S.M.; Zareshahi, H.; Lanjanian, H.; Durrani, S.A.

    2008-01-01

    In this paper attempt has been made to study the influence of temperature and UV light (exist in laboratory due to the fluorescent light or diffused sunlight) on some high dose dosimetry responses that are being used in Yazd Radiation Processing Center (YRPC). The CTA, FWT and B3 film dosimeters were used for this investigation. The correction of the read response of the dosimeters to the real absorbed dose values is very important especially while we need to measure the precise dose values in the medical devices and in foodstuff materials. Yazd city is near to the desert, and so temperature and UV light due to the sun are very different in compare to other cities. Therefore, we tried to investigate the temperature and UV light effects on the dosimeter response in different doses and obtain its variation as a function of temperature (up to ∼60 0 C) and exposure time (up to ∼1 year), respectively

  9. Brachytherapy. High dose rate brachytherapy - Radiation protection: medical sheet ED 4287

    International Nuclear Information System (INIS)

    Celier, D.; Aubert, B.; Vidal, J.P.; Biau, A.; Lahaye, T.; Gauron, C.; Barret, C.; Boisserie, G.; Branchet, E.; Gambini, D.; Gondran, C.; Le Guen, B.; Guerin, C.; Nguyen, S.; Pierrat, N.; Sarrazin, T.; Donnarieix, D.

    2010-02-01

    After having indicated the required authorization to implement brachytherapy techniques, this document presents the various aspects and measures related to radiation protection when performing high-dose-rate brachytherapy treatments. It presents the concerned personnel, describes the operational process, indicates the associated hazards and the risk related to ionizing radiation, and describes how the risk is to be assessed and how exposure levels are to be determined (elements of risk assessment, delimitation of controlled and monitored areas, personnel classification, and choice of the dose monitoring method). It describes the various components of a risk management strategy (risk reduction, technical measures regarding the installation and the personnel, training and information, prevention and medical monitoring). It briefly presents how risk management is to be assessed, and mentions other related risks (biological risk, handling and posture, handling of heavy loads, mental workload, chemical risk)

  10. Human reliability in high dose rate afterloading radiotherapy based on FMECA

    International Nuclear Information System (INIS)

    Deng Jun; Fan Yaohua; Yue Baorong; Wei Kedao; Ren Fuli

    2012-01-01

    Objective: To put forward reasonable and feasible recommendations against the procedure with relative high risk during the high dose rate (HDR) afterloading radiotherapy, so as to enhance its clinical application safety, through studying the human reliability in the process of carrying out the HDR afterloading radiotherapy. Methods: Basic data were collected by on-site investigation and process analysis as well as expert evaluation. Failure mode, effect and criticality analysis (FMECA) employed to study the human reliability in the execution of HDR afterloading radiotherapy. Results: The FMECA model of human reliability for HDR afterloading radiotherapy was established, through which 25 procedures with relative high risk index were found,accounting for 14.1% of total 177 procedures. Conclusions: FMECA method in human reliability study for HDR afterloading radiotherapy is feasible. The countermeasures are put forward to reduce the human error, so as to provide important basis for enhancing clinical application safety of HDR afterloading radiotherapy. (authors)

  11. Polycarbonate-based benzo-δ-sultam films for high-dose dosimetry in radiation processing

    International Nuclear Information System (INIS)

    Feizi, Shazad; Nuclear Science and Technology Research Institute, Tehran; Ziaie, Farhood; Ghandi, Mehdi

    2015-01-01

    In this work characteristics of the polycarbonate films with 20 μm in thickness containing different weight percentage of Benzo-δ-sultam were studied for use as a high dose dosimetry system in radiation processing facilities. The sensitivity of the dosimeters and the linearity of dose-response curves were investigated under 60 Co γ-rays in a dose range of 0-100 kGy, and obtained results were compared with the commercial CTA and FWT film dosimeters. The results show that the absorbance at 348 nm depends linearly on the dose in the investigated dose range. The effects of pre-irradiation (shelf-life) and post-irradiation storage in dark and in indirect sunlight are also discussed. The results show that the dosimeters characteristics are stable within 1% at 25 C, 3 months after the irradiation.

  12. Polycarbonate-based benzo-δ-sultam films for high-dose dosimetry in radiation processing

    Energy Technology Data Exchange (ETDEWEB)

    Feizi, Shazad [University of Tehran, Tehran (India). School of Chemistry; Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of). Radiation Application Research School; Ziaie, Farhood [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of). Radiation Application Research School; Ghandi, Mehdi [University of Tehran, Tehran (India). School of Chemistry

    2015-05-01

    In this work characteristics of the polycarbonate films with 20 μm in thickness containing different weight percentage of Benzo-δ-sultam were studied for use as a high dose dosimetry system in radiation processing facilities. The sensitivity of the dosimeters and the linearity of dose-response curves were investigated under {sup 60}Co γ-rays in a dose range of 0-100 kGy, and obtained results were compared with the commercial CTA and FWT film dosimeters. The results show that the absorbance at 348 nm depends linearly on the dose in the investigated dose range. The effects of pre-irradiation (shelf-life) and post-irradiation storage in dark and in indirect sunlight are also discussed. The results show that the dosimeters characteristics are stable within 1% at 25 C, 3 months after the irradiation.

  13. High dose effect of gamma and neutrons on the N-JFET electronic components

    International Nuclear Information System (INIS)

    Assaf, Jamal-Eddin

    2006-11-01

    Two types of N-JFET components have been irradiated by high doses of thermal neutrons and gamma rays up to 2000x10 12 n/cm 2 and 1000 kGy, respectively. The static tests show a decrease of the g m and I d s parameters. The behaviour of electronic noise on the output was the principal dynamic test after irradiation. The result of this test gives an increase of the noise with radiation dose increasing. The noise was described as the Equivalent Noise of Charge (ENC) at the output of the measurements set-up. The quantities and the qualities of the noise depend on the N-JEET type and the type of radiation (neutrons or gamma). Other tests were carried out like the relaxation or recovery phenomena after radiation, and the superposed effects of gamma and neutrons.(author)

  14. Low dose rate and high dose rate intracavitary treatment for cervical cancer

    International Nuclear Information System (INIS)

    Hareyama, Masato; Oouchi, Atsushi; Shidou, Mitsuo

    1997-01-01

    From 1984 through 1993, 144 previous untreated patients with carcinoma of uterine cervix were treated with either low dose rate 137 Cs therapy (LDR) or high dose rate 60 Co therapy (HDR). The local failure rates for more than 2-years for the primary lesions were 11.8% (8 of 63 patients) for LDR and 18.0% (11 of 61 patients). Rectal complication rates were significantly lower for HDR versus LDR (14.3% VS. 32.8%. p<0.01). Also, bladder complication rates were significantly lower for HDR versus LDR (0% VS. 10.4%, p<0.005). Treatment results in term of local control were equivalent for HDR and LDR treatment. However, the incidence of complications was higher for the LDR group than for the HDR group. (author)

  15. CD34-positive cells as stem cell support after high dose therapy

    International Nuclear Information System (INIS)

    Kvalheim, G.; Pharo, A.; Holte, H.

    1996-01-01

    Six patients, five with breast cancer and one with non-Hodgkin's lymphoma, were mobilized by chemotherapy and G-CSF. CD34-positive cells were isolated by means of immunomagnetic beads and Isolex 300 Cell Separator. Mean purity of isolated CD34-positive cells was 97% and mean yield was 54%. Three patients were treated with high dose therapy followed by reinfusion of CD34-positive cells as stem cell support. Recovery of neutrophils occurred at day 8, 11 and 13 and of platelets at day 9, 14 and 32. It is concluded that immunomagnetic isolated CD34-positive cells give high purity and yield. Although use of CD34-positive cells reduces the content of contaminating tumours cells in the graft, breast cancer cells were still detectable in two out of five CD34-positive cell products. 20 refs., 2 figs., 1 tab

  16. Safety and toxicology assessment of chicken breast for high-dose irradiation

    International Nuclear Information System (INIS)

    Zhu Jiating; Feng Min; Yan Jianmin; Yang Ping; Wang Dening; Gao Meixu; Ha Yiming; Liu Chunquan

    2011-01-01

    Feeding wholesomeness tests of irradiated chicken breast were studied by using acute oral toxicology, Ames, micronucleus of born marrow cell, sperm shape abnormality in mice and 30 d feeding test. The LD 50 of all the rats and mice were more than 10 g/kg · BW, which means that the pet foods belonged to actually non-toxic grade; ames test, and the tests of micronucleus of born marrow cell, sampan shape abnormality in mice were all negative results; 30 d feeding test in rats demonstrated that it had no distinctive effects on routine blood, body weight and biochemical index. It is concluded that pet foods irradiated up to 25 kGy high dose were no safety and toxicology problems. (authors)

  17. High dose-rate brachytherapy source localization: positional resolution using a diamond detector

    International Nuclear Information System (INIS)

    Nakano, T; Suchowerska, N; Bilek, M M; McKenzie, D R; Ng, N; Kron, T

    2003-01-01

    A potential real-time source position verification process for high dose-rate (HDR) brachytherapy treatment is described. This process is intended to provide immediate confirmation that a treatment is proceeding according to plan, so that corrective action can be taken if necessary. We show that three dosimeters are in principle sufficient and demonstrate the feasibility of the process using a diamond detector and an Ir-192 source. An error analysis including all identified sources of error shows that this detector is capable of locating the distance to the source to within 2 mm for distances up to 12 cm. This positional accuracy is less than the diameter of typical HDR catheters indicating that a diamond detector can be used to accurately determine the distance to the source. The uncertainty in the distance is found to increase with distance

  18. Radiation exposure for 'caregivers' during high-dose outpatient radioiodine therapy

    International Nuclear Information System (INIS)

    Marriott, C. J.; Webber, C. E.; Gulenchyn, K. Y.

    2007-01-01

    On 27 occasions, radiation doses were measured for a family member designated as the 'caregiver' for a patient receiving high-dose radioiodine outpatient therapy for differentiated thyroid carcinoma. For 25 of the administrations, patients received 3.7 GBq of 131 I. Radiation doses for the designated caregivers were monitored on an hourly basis for 1 week using electronic personal dosemeters. The average penetrating dose was 98±64 μSv. The maximum penetrating dose was 283 μSv. Measured dose rate profiles showed that, on average, one-third of the caregiver dose was received during the journey home from hospital. The mean dose rate profile showed rapid clearance of 131 I with three distinct phases. The corresponding clearance half-times were 131 I contaminating the home. (authors)

  19. Allogeneic bone marrow transplantation in adults after fractionated body irradiation and high dose cyclophosphamide

    International Nuclear Information System (INIS)

    Brinch, L.; Evensen, S.A.; Albrechtsen, D.; Egeland, T.; Solheim, B.G.; Rollag, H.; Naalsund, A.; Jacobsen, A.B.

    1991-01-01

    The authors present short and long-term results of allogeneic bone marrow transplantation after hyper-fractionated total body irradiation and high dose cyclophosphamide in ten patients treated for leukaemia during th period 1985-89. Three patients died from complications connected to the transplantation, while seven are living free from leukaemia 18 to 59 months after transplantation. Two patients need treatment for chronic graft versus host disease. Allogeneic bone marrow transplantation is expensive and risky. Close cooperation between clinicians and laboratory specialists is essential. The treatment increases long term survival and probably cures certain patients with leukaemia. Some of the patients will need treatment for chronic graft versus host disease and other late sequelae. 19 refs., 2 tabs

  20. Controlled localised melting in silicon by high dose germanium implantation and flash lamp annealing

    International Nuclear Information System (INIS)

    Voelskow, Matthias; Skorupa, Wolfgang; Pezoldt, Joerg; Kups, Thomas

    2009-01-01

    High intensity light pulse irradiation of monocrystalline silicon wafers is usually accompanied by inhomogeneous surface melting. The aim of the present work is to induce homogeneous buried melting in silicon by germanium implantation and subsequent flash lamp annealing. For this purpose high dose, high energy germanium implantation has been employed to lower the melting temperature of silicon in a predetermined depth region. Subsequent flash lamp irradiation at high energy densities leads to local melting of the germanium rich buried layer, whereby the thickness of the molten layer depends on the irradiation energy density. During the cooling down epitaxial crystallization takes place resulting in a largely defect-free layer. The combination of buried melting and dopant segregation has the potential to produce unusually buried doping profiles or to create strained silicon structures.

  1. Study of the response reduction of LiF:Mg, Ti dosimeter for high dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Torkzadeh, Falamarz [Nuclear Sciences and Technology Research Institute, Tehran (Iran, Islamic Republic of). Radiation Applications Research School; AEOI, Tehran (Iran, Islamic Republic of); Faripour, Heidar [Nuclear Sciences and Technology Research Institute, Tehran (Iran, Islamic Republic of). Laser and Optics Research School; AEOI, Tehran (Iran, Islamic Republic of); Mardashti, Forough; Manouchehri, Farhad [Nuclear Sciences and Technology Research Institute, Tehran (Iran, Islamic Republic of). Radiation Applications Research School

    2017-07-15

    A single crystal and 5 polycrystalline samples of LiF:Mg, Ti and their pellets were prepared and investigated so as to apply thermoluminescence high gamma dose dosimetry. Three zones of single crystal with dopant concentrations of 200 ppm of Mg and 20 ppm of Ti were also used to prepare the single crystal samples. For polycrystalline samples, dopant concentrations of 0.062 mol% Mg and Ti concentrations in the range of 0.016 and 0.046 mol% were used. All the samples were exposed to gamma doses of 1 kGy to 700 kGy and their response changes were determined by a gamma dose test of about 60 mGy. According to the results obtained, the use of response reduction by curve-fitting up to about 300 kGy can be performed reliably for high dose gamma dosimetry.

  2. Case of severe intestinal complications caused by high dose-rate intracavitary irradiation for cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Kenji; Nishikawa, Kiyoshi; Matsuki, Kazuhiko; Watanabe, Katsushi

    1987-02-01

    A 46-year-old woman with severe intestinal complication caused by high dose-rate intracavitary irradiation is reported. She received radiation treatment of stage IIb cervical cancer between July 24 and September 26, 1984: a dose of 2400 rad to a point A concurrently with 2000 rad to the parametrium following 4000 rad to the whole pelvis. Eight months later she developed diarrhea and bloody stool. Barium enema study revealed a stenosis at 20 to 25 cm from the anal ring and romanoscopy oozing coagula at the same site. On November 29, 1985 transverse colostomy was performed because of continuing bloody stool and abdominal pain. On January 30, 1986 resection of the ileum and ileostomy were done because of the ileum perforation located 26 cm apart from the ileum end. Some discussion on the causes of this complication are made, suggesting that short length of a tandem and deep location of ovoids influence its cause.

  3. Dosimetric Effects of Air Pockets Around High-Dose Rate Brachytherapy Vaginal Cylinders

    International Nuclear Information System (INIS)

    Richardson, Susan; Palaniswaamy, Geethpriya; Grigsby, Perry W.

    2010-01-01

    Purpose: Most physicians use a single-channel vaginal cylinder for postoperative endometrial cancer brachytherapy. Recent published data have identified air pockets between the vaginal cylinders and the vaginal mucosa. The purpose of this research was to evaluate the incidence, size, and dosimetric effects of these air pockets. Methods and Materials: 25 patients receiving postoperative vaginal cuff brachytherapy with a high-dose rate vaginal cylinders were enrolled in this prospective data collection study. Patients were treated with 6 fractions of 200 to 400 cGy per fraction prescribed at 5 mm depth. Computed tomography simulation for brachytherapy treatment planning was performed for each fraction. The quantity, volume, and dosimetric impact of the air pockets surrounding the cylinder were quantified. Results: In 25 patients, a total of 90 air pockets were present in 150 procedures (60%). Five patients had no air pockets present during any of their treatments. The average number of air pockets per patient was 3.6, with the average total air pocket volume being 0.34 cm 3 (range, 0.01-1.32 cm 3 ). The average dose reduction to the vaginal mucosa at the air pocket was 27% (range, 9-58%). Ten patients had no air pockets on their first fraction but air pockets occurred in subsequent fractions. Conclusion: Air pockets between high-dose rate vaginal cylinder applicators and the vaginal mucosa are present in the majority of fractions of therapy, and their presence varies from patient to patient and fraction to fraction. The existence of air pockets results in reduced radiation dose to the vaginal mucosa.

  4. High-Dose-Rate Endobronchial Brachytherapy for Recurrent Airway Obstruction From Hyperplastic Granulation Tissue

    International Nuclear Information System (INIS)

    Tendulkar, Rahul D.; Fleming, Peter A.; Reddy, Chandana A.; Gildea, Thomas R.; Machuzak, Michael; Mehta, Atul C.

    2008-01-01

    Purpose: Benign endobronchial granulation tissue causes airway obstruction in up to 20% of patients after lung transplantation or stent placement. High-dose-rate endobronchial brachytherapy (HDR-EB) has been successful in some cases refractory to standard bronchoscopic interventions. Methods and Materials: Between September 2004 and May 2005, 8 patients with refractory benign airway obstruction were treated with HDR-EB, using one to two fractions of Ir-192 prescribed to 7.1 Gy at a radius of 1 cm. Charts were retrospectively reviewed to evaluate subjective clinical response, forced expiratory volume in 1 second (FEV 1 ), and frequency of therapeutic bronchoscopies over 6-month periods before and after HDR-EB. Results: The median follow-up was 14.6 months, and median survival was 10.5 months. The mean number of bronchoscopic interventions improved from 3.1 procedures in the 6-month pretreatment period to 1.8 after HDR-EB. Mean FEV 1 improved from 36% predicted to 46% predicted. Six patients had a good-to-excellent subjective early response, but only one maintained this response beyond 6 months, and this was the only patient treated with HDR-EB within 24 h from the most recent bronchoscopic intervention. Five patients have expired from causes related to their chronic pulmonary disease, including one from hemoptysis resulting from a bronchoarterial fistula. Conclusion: High-dose-rate-EB may be an effective treatment for select patients with refractory hyperplastic granulation tissue causing recurrent airway stenosis. Performing HDR-EB within 24-48 h after excision of obstructive granulation tissue could further improve outcomes. Careful patient selection is important to maximize therapeutic benefit and minimize toxicity. The optimal patient population, dose, and timing of HDR-EB should be investigated prospectively

  5. A comparison of high dose Ga-67 SPECT and FDG PET imaging in malignant melanoma

    International Nuclear Information System (INIS)

    Kaliff, V.; Hicks, R.J.; Binns, D.S.; Henderson, M.A.; Ainslie, J.; Jenner, D.A.

    1998-01-01

    Full text: Ga-67 imaging for tumour localisation lost favour in the 1970's. With improvement in technology and use of higher doses, it has now found an important role in lymphoma. A similar phenomenon may be possible in the staging of melanoma. This study therefore compares high dose (370 MBq) Ga-67 imaging using a day 5 and 7 whole-body and comprehensive SPECT protocol, with (100 MBq) F-18 fluorodeoxyglucose (FDG) imaging using positron emission tomography (PET): a technique recently shown to be highly accurate in this condition. 85 patients; 46 males, mean age 52+17 yrs: range 22-83 yrs, underwent both studies within 9±16 days (max-91 days). Scans were judged as positive (+ve), negative (-ve) or equivocal (EQ) for local, regional and distant disease. Clinical follow-up resolved discordant scan findings. PET and Ga-67 results were concordant in 61 (70%) patients (19 with +ve, 37 -ve and 5 EQ scans). None of the 9 ps with one EQ and one eye scan had disease on follow-up. Follow-up was available in 4/5 patients with discordantly +ve (3 patients) or more extensive Ga-67 abnormality: 3 patients had disease confirmed, 1 patient false +ve (asymmetric lung hilum). Follow-up was available in 9/10 patients with discordantly +ve (3 patients) or more extensive PET abnormality: 4 patients had confirmed disease, l pt false +ve (bladder diverticulum). A further 4 patients had second primaries (2 rectal carcinomas, 1 plasmacytoma, 1 basal cell carcinoma). High dose Ga-67 scanning incorporating SPECT appears to be a reasonable alternative to FDG PET for screening patients with melanoma. In this series PET's main advantages were in the detection of other occult tumours, greater patient convenience and lower radiation dosimetry

  6. Interstitial high-dose rate brachytherapy as boost for anal canal cancer

    International Nuclear Information System (INIS)

    Falk, Alexander Tuan; Claren, Audrey; Benezery, Karen; François, Eric; Gautier, Mathieu; Gerard, Jean-Pierre; Hannoun-Levi, Jean-Michel

    2014-01-01

    To assess clinical outcomes of patients treated with a high-dose rate brachytherapy boost for anal canal cancer (ACC). From August 2005 to February 2013, 28 patients presenting an ACC treated by split-course external beam radiotherapy (EBRT) and HDR brachytherapy with or without chemotherapy in a French regional cancer center in Nice were retrospectively analyzed. Median age was 60.6 years [34 – 83], 25 patients presented a squamous cell carcinoma and 3 an adenocarcinoma; 21 received chemotherapy. Median dose of EBRT was 45 Gy [43.2 – 52]. Median dose of HDR brachytherapy was 12 Gy [10 - 15] with a median duration of 2 days. Median overall treatment time was 63 days and median delay between EBRT and brachytherapy was 20 days. Two-year local relapse free, metastatic free, disease free and overall survivals were 83%, 81.9%, 71.8% and 87.7% respectively. Acute toxicities were frequent but not severe with mostly grade 1 toxicities: 37% of genito-urinary, 40.7% of gastro-intestinal and 3.7% of cutaneous toxicities. Late toxicities were mainly G1 (43.1%) and G2 (22%). Two-year colostomy-free survival was 75.1%, one patient had a definitive sphincter amputation. High-dose rate brachytherapy for anal canal carcinoma as boost represents a feasible technique compared to low or pulsed-dose rate brachytherapy. This technique remains an excellent approach to precisely boost the tumor in reducing the overall treatment time

  7. Implementation of microsource high dose rate (mHDR) brachytherapy in developing countries

    International Nuclear Information System (INIS)

    2001-11-01

    Brachytherapy using remote afterloading of a single high dose rate 192 Ir microsource was developed in the 1970s. After its introduction to clinics, this system has spread rapidly among developed Member States and has become a highly desirable modality in cancer treatment. This technique is now gradually being introduced to the developing Member States. The 192 Ir sources are produced with a high specific activity. This results in a high dose rate (HDR) to the tumour and shorter treatment times. The high specific activity simultaneously results in a much smaller source (so-called micro source, around I mm in diameter) which may be easily inserted into tissue through a thin delivery tube, the so-called interstitial treatment, as well as easily inserted into body cavities, the so-called intracavitary or endoluminal treatment. Another advantage is the ability to change dwell time (the time a source remains in one position) of the stepping source which allows dose distribution to match the target volume more closely. The purpose of this TECDOC is to advise radiation oncologists, medical physicists and hospital administrators in hospitals which are planning to introduce 192 Ir microsource HDR (mHDR) remote afterloading systems. The document supplements IAEA-TECDOC-1040, Design and Implementation of a Radiotherapy Programme: Clinical, Medical Physics, Radiation Protection and Safety Aspects, and will facilitate implementation of this new brachytherapy technology, especially in developing countries. The operation of the system, 'how to use the system', is not within the scope of this document. This TECDOC is based on the recommendations of an Advisory Group meeting held in Vienna in April 1999

  8. Fatherhood in tall men treated with high-dose sex steroids during adolescence.

    Science.gov (United States)

    Hendriks, A E J; Boellaard, W P A; van Casteren, N J; Romijn, J C; de Jong, F H; Boot, A M; Drop, S L S

    2010-12-01

    Sex steroid treatment to reduce final height of tall boys has been available since the 1950s. In women, it has been shown to interfere with fertility. In men, no such data are available. We therefore evaluated fertility and gonadal function in tall men who did or did not receive high-dose androgen treatment in adolescence. We conducted a retrospective cohort study of 116 tall men, of whom 60 had been treated. Reproductive and gonadal function was assessed by standardized interview, semen analysis, endocrine parameters, ultrasound imaging, and fatherhood. Mean age at treatment commencement was 14.2 yr, and mean follow-up was 21.2 yr. Sixty-six men (36 treated and 30 untreated) had attempted to achieve fatherhood. The probability of conceiving their first pregnancy within 1 yr was similar in treated and untreated men (26 vs. 24; Breslow P=0.8). Eleven treated and 13 untreated men presented with a left-sided varicocele (P=0.5). Testicular volume, sperm quality, and serum LH, FSH, and inhibin B levels were comparable between treated and untreated men. However, treated men had significantly reduced serum T levels, adjusted for known confounders [mean (sd) 13.3 (1.8) vs. 15.2 (1.9) nmol/liter; P=0.005). In addition, testicular volume and serum inhibin B and FSH levels in treated men were significantly correlated with age at treatment commencement. At a mean follow-up of 21 yr after high-dose androgen treatment, we conclude that fatherhood and semen quality in tall treated men are not affected. Serum testosterone levels, however, are reduced in androgen-treated men. Future research is required to determine whether declining testosterone levels may become clinically relevant for these men as they age.

  9. Plasma methylphenidate concentrations in youths treated with high-dose osmotic release oral system formulation.

    Science.gov (United States)

    Stevens, Jonathan R; George, Robert A; Fusillo, Steven; Stern, Theodore A; Wilens, Timothy E

    2010-02-01

    Children and adolescents are being treated increasingly for attention-deficit/hyperactivity disorder (ADHD) with a variety of stimulants in higher than Food and Drug Administration (FDA)-approved doses and in combination with other medications. We sought to determine methylphenidate (MPH) concentrations in children and adolescents treated with high-dose, extended-release osmotic release oral system (OROS) MPH plus concomitant medications, and to examine MPH concentrations with respect to the safety and tolerability of treatment. Plasma MPH concentrations were measured by liquid chromatography-mass spectrometry 4-5 hours after administration of medication in a sample of youths diagnosed with ADHD. These youths were treated naturalistically with higher than FDA-approved doses of OROS MPH in addition to their concomitant medications. Markers of safety and tolerability (e.g., measures of blood pressure and heart rate) were also examined. Among the 17 patients (with a mean age of 16.2 +/- 2 years and a mean number of concurrent medications of 2.23 +/- 0.94), the mean plasma MPH concentration was 28 +/- 9.1 ng/mL, despite a mean daily dose of OROS MPH of 169 +/- 5 mg (3.0 +/- 0.8 mg/kg per day). No patient had a plasma MPH level >or=50 ng/mL or clinical signs of stimulant toxicity. No correlation was found between plasma MPH concentrations and OROS MPH dose or changes in vital signs. High-dose OROS MPH, used in combination with other medications, was not associated with either unusually elevated plasma MPH concentrations or with clinically meaningful changes in vital signs. Study limitations include a single time-point sampling of MPH concentrations, a small sample size, and a lack of outcome measures to address treatment effectiveness.

  10. High-dose simultaneously integrated breast boost using intensity-modulated radiotherapy and inverse optimization

    International Nuclear Information System (INIS)

    Hurkmans, Coen W.; Meijer, Gert J.; Vliet-Vroegindeweij, Corine van; Sangen, Maurice J. van der; Cassee, Jorien

    2006-01-01

    Purpose: Recently a Phase III randomized trial has started comparing a boost of 16 Gy as part of whole-breast irradiation to a high boost of 26 Gy in young women. Our main aim was to develop an efficient simultaneously integrated boost (SIB) technique for the high-dose arm of the trial. Methods and Materials: Treatment planning was performed for 5 left-sided and 5 right-sided tumors. A tangential field intensity-modulated radiotherapy technique added to a sequentially planned 3-field boost (SEQ) was compared with a simultaneously planned technique (SIB) using inverse optimization. Normalized total dose (NTD)-corrected dose volume histogram parameters were calculated and compared. Results: The intended NTD was produced by 31 fractions of 1.66 Gy to the whole breast and 2.38 Gy to the boost volume. The average volume of the PTV-breast and PTV-boost receiving more than 95% of the prescribed dose was 97% or more for both techniques. Also, the mean lung dose and mean heart dose did not differ much between the techniques, with on average 3.5 Gy and 2.6 Gy for the SEQ and 3.8 Gy and 2.6 Gy for the SIB, respectively. However, the SIB resulted in a significantly more conformal irradiation of the PTV-boost. The volume of the PTV-breast, excluding the PTV-boost, receiving a dose higher than 95% of the boost dose could be reduced considerably using the SIB as compared with the SEQ from 129 cc (range, 48-262 cc) to 58 cc (range, 30-102 cc). Conclusions: A high-dose simultaneously integrated breast boost technique has been developed. The unwanted excessive dose to the breast was significantly reduced

  11. Dose intercomparison studies for standardization of high-dose dosimetry in Viet Nam

    International Nuclear Information System (INIS)

    Mai Hoang Hoa; Duong Nguyen Dinh; Kojima, T.

    1999-01-01

    The Irradiation Center of the Vietnam Atomic Energy Commission (IC-VAEC) is planning to establish a traceability system for high-dose dosimetry and to provide high-dose standards as a secondary standard dosimetry laboratory (SSDL) level in Vietnam. For countries which do not have a standard dosimetry laboratory, the participation in the International Dose Assurance Service (IDAS) operated by the International Atomic Energy Agency (IAEA) is the most common means to verify own dosimetry performance with a certain uncertainty. This is, however, only one-direction dose intercomparison with evaluation by IAEA including unknown parameter at participant laboratories. The SSDL level laboratory should have traceability as well as compatibility, ability to evaluate uncertainties of its own dosimetry performance by itself In the present paper, we reviewed our dosimetry performance through two-way dose intercomparison studies and self-evaluation of uncertainty in our dosimetry procedure. The performance of silver dichromate dosimeter as reference transfer dosimeter in IC-VAEC was studied through two-way blind dose intercomparison experiments between the IC-VAEC and JAERI. As another channel of dose intercomparison with IAEA, alanine dosimeters issued by IDAS were simultaneously irradiated with the IC-VAEC dichromate dosimeters at IC-VAEC and analyzed by IAEA. Dose intercomparison between IC-VAEC and JAERI results into a good agreement (better than ±2.5%), and IDAS results also show similar agreement within ±3.0%. The uncertainty was self-estimated on the basis of the JAERI alanine dosimetry, and a preliminary value of about 1.86% at a 68% confidence level is established. The results from these intercomparisons and our estimation of the uncertainty are consistent. We hope that our experience is valuable to other countries which do not have dosimetry standard laboratories and/or are planning to establish them. (author)

  12. Gafchromic EBT-XD film: Dosimetry characterization in high-dose, volumetric-modulated arc therapy.

    Science.gov (United States)

    Miura, Hideharu; Ozawa, Shuichi; Hosono, Fumika; Sumida, Naoki; Okazue, Toshiya; Yamada, Kiyoshi; Nagata, Yasushi

    2016-11-08

    Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT-XD films have been designed for optimal performance in the 40-4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose-response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high-dose volumetric-modulated arc therapy (VMAT) verification. A 10 MV beam from a TrueBeam STx linear accelerator was used to irradiate the films with doses in the 0-4,000 cGy range. Postexposure coloration was analyzed at postirradiation times ranging from several minutes to 48 h. The films were also irradiated with 6 MV (dose rate (DR): 600 MU/min), 6 MV flattening filter-free (FFF) (DR: 1,400 MU/ min), and 10 MV FFF (DR: 2,400 MU/min) beams to determine the energy and dose-rate dependence. For clinical examinations, we compared the dose distribu-tion measured with EBT-XD films and calculated by the planning system for four VMAT cases. The red channel of the EBT-XD film exhibited a wider dynamic range than the green and blue channels. Scanner orientation yielded a variation of ~ 3% in the net optical density (OD). The difference between the film front and back scan orientations was negligible, with variation of ~ 1.3% in the net OD. The net OD increased sharply within the first 6 hrs after irradiation and gradually afterwards. No significant difference was observed for the beam energy and dose rate, with a variation of ~ 1.5% in the net OD. The gamma passing rates (at 3%, 3 mm) between the film- measured and treatment planning system (TPS)-calculated dose distributions under a high dose VMAT plan in the absolute dose mode were more than 98.9%. © 2016 The Authors.

  13. High doses of the histone deacetylase inhibitor sodium butyrate trigger a stress-like response.

    Science.gov (United States)

    Gagliano, Humberto; Delgado-Morales, Raul; Sanz-Garcia, Ancor; Armario, Antonio

    2014-04-01

    The hypothalamic-pituitary-adrenal (HPA) axis is activated by a wide range of stimuli, including drugs. Here we report that in male rats, a dose of sodium butyrate (NaBu) that is typically used to inhibit histone deacetylation (1200 mg/kg) increased the peripheral levels of HPA hormones and glucose. In a further experiment, we compared the effects of two different doses of NaBu (200 and 1200 mg/kg) and equimolar saline solutions on peripheral neuroendocrine markers and brain c-Fos expression to demonstrate a specific stress-like effect of NaBu that is not related to hypertonicity and to localise putatively involved brain areas. Only the high dose of NaBu increased the plasma levels of stress markers. The equimolar (hypertonic) saline solution also activated the HPA axis and the c-Fos expression in the paraventricular nucleus of the hypothalamus (PVN), a key area for the control of the HPA axis, but the effects were of a lower magnitude than those of NaBu. Regarding other brain areas, group differences in c-Fos expression were not observed in the medial prefrontal cortex or the medial amygdala, but they were observed in the central amygdala and the lateral ventral septum. However, only the latter area of the NaBu group showed enhanced c-Fos expression that was significantly higher than that after hypertonic saline. The present data indicate that high doses of NaBu appear to act as a pharmacological stressor, and this fact should be taken into account when using this drug to study the role of epigenetic processes in learning and emotional behaviour. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. The effects of high dose and highly fractionated radiation on distraction osteogenesis in the murine mandible

    International Nuclear Information System (INIS)

    Monson, Laura A; Cavaliere, Christi M; Deshpande, Sagar S; Ayzengart, Alexander L; Buchman, Steven R

    2012-01-01

    The ability of irradiated tissue to support bony growth remains poorly defined, although there are anecdotal cases reported showing mixed results for the use of mandibular distraction osteogenesis after radiation for head and neck cancer. Many of these reports lack objective measures that would allow adequate analysis of outcomes or efficacy. The purpose of this experiment was to utilize a rat model of mandibular distraction osteogenesis after high dose and highly fractionated radiation therapy and to evaluate and quantify distracted bone formation under these conditions. Male Sprague–Dawley rats underwent 12 fractions of external beam radiation (48 Gray) of the left mandible. Following a two week recovery period, an external frame distractor was applied and gradual distraction of the mandible was performed. Tissue was harvested after a twenty-eight day consolidation period. Gross, radiologic and histological evaluations were undertaken. Those animals subjected to pre-operative radiation showed severe attenuation of bone formation including bone atrophy, incomplete bridging of the distraction gap, and gross bony defects or non-union. Although physical lengthening was achieved, the irradiated bone consistently demonstrated marked damaging effects on the normal process of distraction osteogenesis. This murine model has provided reliable evidence of the injurious effects of high dose radiation on bone repair and regeneration in distraction osteogenesis utilizing accurate and reproducible metrics. These results can now be used to assist in the development of therapies directed at mitigating the adverse consequences of radiation on the regeneration of bone and to optimize distraction osteogenesis so it can be successfully applied to post-oncologic reconstruction

  15. Drug elution from high-dose antibiotic-loaded acrylic cement: a comparative, in vitro study.

    Science.gov (United States)

    Gasparini, Giorgio; De Gori, Marco; Calonego, Giovanni; Della Bora, Tommaso; Caroleo, Benedetto; Galasso, Olimpio

    2014-11-01

    High-dose antibiotic-loaded acrylic cement (ALAC) is used for managing peri-prosthetic joint infections (PJIs). The marked increase in resistant high-virulence bacteria is drawing the attention of physicians toward alternative antimicrobial formulations loaded into acrylic bone cement. The aim of this in vitro study was to determine the elution kinetics of 14 different high-dose ALACs. All ALAC samples showed a burst release of antibiotics in the first hour, progressively decreasing over time, and elution curves strictly adhered to a nonlinear regression analysis formula. Among aminoglycosides, commonly seen as the most appropriate antibiotics to be loaded into the bone cement, the highest elution rate was that of tobramycin. Among the glycopeptides, a class of antibiotics that should be considered to treat PJIs because of the prevalence of aminoglycoside resistance, vancomycin showed better elution than teicoplanin. Clindamycin, which can be associated with aminoglycosides to prepare ALACs and represents a useful option against the most common pathogens responsible for PJIs, showed the highest absolute and relative elutions among all the tested formulations. A noticeable elution was also detected for colistin, an antibiotic of last resort for treating multidrug-resistant bacteria. The current study demonstrates theoretical advantages in the preparation of ALAC for some antibiotics not routinely used in the clinical setting for PJIs. The use of these antibiotics based on the infecting bacteria sensitivity may represent a useful option for physicians to eradicate PJIs. In vivo testing should be considered in the future to confirm the results of this study. Copyright 2014, SLACK Incorporated.

  16. High doses of dextromethorphan, an NMDA antagonist, produce effects similar to classic hallucinogens

    Science.gov (United States)

    Carter, Lawrence P.; Johnson, Matthew W.; Mintzer, Miriam Z.; Klinedinst, Margaret A.; Griffiths, Roland R.

    2013-01-01

    Rationale Although reports of dextromethorphan (DXM) abuse have increased recently, few studies have examined the effects of high doses of DXM. Objective This study in humans evaluated the effects of supratherapeutic doses of DXM and triazolam. Methods Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg/70kg), and placebo were administered to twelve healthy volunteers with histories of hallucinogen use, under double-blind conditions, using an ascending dose run-up design. Subjective, behavioral, and physiological effects were assessed repeatedly after drug administration for 6 hours. Results Triazolam produced dose-related increases in subject-rated sedation, observer-rated sedation, and behavioral impairment. DXM produced a profile of dose-related physiological and subjective effects differing from triazolam. DXM effects included increases in blood pressure, heart rate, and emesis, increases in observer-rated effects typical of classic hallucinogens (e.g. distance from reality, visual effects with eyes open and closed, joy, anxiety), and participant ratings of stimulation (e.g. jittery, nervous), somatic effects (e.g. tingling, headache), perceptual changes, end-of-session drug liking, and mystical-type experience. After 400 mg/70kg DXM, 11 of 12 participants indicated on a pharmacological class questionnaire that they thought they had received a classic hallucinogen (e.g. psilocybin). Drug effects resolved without significant adverse effects by the end of the session. In a 1-month follow up volunteers attributed increased spirituality and positive changes in attitudes, moods, and behavior to the session experiences. Conclusions High doses of DXM produced effects distinct from triazolam and had characteristics that were similar to the classic hallucinogen psilocybin. PMID:22526529

  17. Gynogenesis with high doses of gamma radiation in tomatoes -Lycopersicum esculentum Mill. (L.)

    International Nuclear Information System (INIS)

    Dryanovska, O.A.

    1983-01-01

    The behaviour of male chromatin at the germination of gamma irradiated pollen from the stigma to the embrio sac in tomatoes was investigated in connection with the induced gynogenesis and the transfer of genetic information from one species to another. Two male-sterile longistil varieties of Deva and Hera were used as mothers, while mixed pollen from cultivated varieties and Lycopersicum peruvianum (L.) was irradiated at doses of 1, 5, 10 and 200 Kr with a dose rate of up to 1500 R/min. The experiment was carried out in 6 replications, with between 3 and 15 flowers for each variant and variety. The irradiated male chromatin of L. peruvianum remains in the pollen tube that has grown close to the embryo sac and stimulates the development of the embryo and endosperm. The absense of anthocyanin and the normal diploid chromosome count were the two markers for characterizing the plants obtained at high doses of gamma radiation as secondarily diploidized gynogenetic diplo-haploids during embryogenesis. It is assumed that the highly damaged male chromatin and the cytoplasm of the pollen tube retain their stimulating function under the influence of the high doses. A decisive role may be placed by certain fragments with genes from the male chromatin. The mitochondria which retain their respirative capacity and are promptly restored even after irradiation may have a stimmulating influence at the induced haploidy. The secondary diploidization normalizes the development of the organism of haploid origin and makes it possible to overcome the poor viability and the higher sterility. The genes responsible for the synthesis of anthocyanin in the irradiated male chromatin are restroyed by the high radiation doses, and this is the reason for the absence of anthocyanin in the diplo-haploid plants

  18. Usefulness of high-dose intravenous human immunoglobulins treatment for refractory recurrent pericarditis.

    Science.gov (United States)

    Moretti, Michele; Buiatti, Alessandra; Merlo, Marco; Massa, Laura; Fabris, Enrico; Pinamonti, Bruno; Sinagra, Gianfranco

    2013-11-01

    The management of refractory recurrent pericarditis is challenging. Previous clinical reports have noted a beneficial effect of high-dose intravenous human immunoglobulins (IvIgs) in isolated and systemic inflammatory disease-related forms. In this article, we analyzed retrospectively our clinical experience with IvIg therapy in a series of clinical cases of pericarditis refractory to conventional treatment. We retrospectively analyzed 9 patients (1994 to 2010) with refractory recurrent pericarditis, who received high-dose IvIg as a part of their medical treatment. Nonsteroidal anti-inflammatory drugs (NSAIDs), steroids, or colchicine treatment was not discontinued during IvIg treatment. No patients had a history of autoimmune or connective tissue diseases. During an average period of 11 months from the first recurrence, patients had experienced a mean of 5 relapses before the first IvIg treatment. In 4 cases, patients showed complete clinical remission with no further relapse after the first IvIg cycle. Two patients experienced a single minor relapse, responsive to short-term nonsteroidal anti-inflammatory drugs. In 2 patients, we performed a second cycle of IvIg after a recurrence of pericarditis, with subsequent complete remission. One patient did not respond to 3 cycles of IvIg and subsequently underwent pericardial window and long-term immunosuppressive treatment. No major adverse effect was observed in consequence of IvIg administration in all the cases. In conclusion, although IvIg mode of action is still poorly understood in this setting, this treatment can be considered as an option in patients with recurrent pericarditis refractory to conventional medical treatment and, in our small series, has proved to be effective in 8 of 9 cases. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Recyclable organic solar cells on substrates comprising cellulose nanocrystals (CNC)

    Science.gov (United States)

    Kippelen, Bernard; Fuentes-Hernandez, Canek; Zhou, Yinhua; Moon, Robert; Youngblood, Jeffrey P

    2015-12-01

    Recyclable organic solar cells are disclosed herein. Systems and methods are further disclosed for producing, improving performance, and for recycling the solar cells. In certain example embodiments, the recyclable organic solar cells disclosed herein include: a first electrode; a second electrode; a photoactive layer disposed between the first electrode and the second electrode; an interlayer comprising a Lewis basic oligomer or polymer disposed between the photoactive layer and at least a portion of the first electrode or the second electrode; and a substrate disposed adjacent to the first electrode or the second electrode. The interlayer reduces the work function associated with the first or second electrode. In certain example embodiments, the substrate comprises cellulose nanocrystals that can be recycled. In certain example embodiments, one or more of the first electrode, the photoactive layer, and the second electrode may be applied by a film transfer lamination method.

  20. Resonant power converter comprising adaptive dead-time control

    DEFF Research Database (Denmark)

    2017-01-01

    The invention relates in a first aspect to a resonant power converter comprising: a first power supply rail for receipt of a positive DC supply voltage and a second power supply rail for receipt of a negative DC supply voltage. The resonant power converter comprises a resonant network with an input...... terminal for receipt of a resonant input voltage from a driver circuit. The driver circuit is configured for alternatingly pulling the resonant input voltage towards the positive and negative DC supply voltages via first and second semiconductor switches, respectively, separated by intervening dead......-time periods in accordance with one or more driver control signals. A dead-time controller is configured to adaptively adjusting the dead-time periods based on the resonant input voltage....

  1. Outcomes of autologous transplantation for multiple myeloma according to different induction regimens

    Directory of Open Access Journals (Sweden)

    Edvan de Queiroz Crusoe

    2014-01-01

    Full Text Available Background: Induction therapy followed by high-dose chemotherapy and autologous transplantation is the standard treatment for suitable patients with multiple myeloma. Objective: The aim of this study was to assess whether induction therapy with thalidomidecontaining regimens was associated with improved results compared to vincristine, doxorubicin, and dexamethasone, and whether cyclophosphamide, thalidomide, and dexamethasone were associated with better results than thalidomide and dexamethasone. Methods: The records of 152 patients who underwent autologous transplantation at this institution from August of 2004 to January of 2012 were reviewed, selecting those with at least partial response to a maximum of eight cycles of induction therapy and sufficient follow-up information for analysis. Results: This study included 89 patients; 44 were female, with a mean age of 55 years (there was a significant trend for increasing age over the years of the study.The median number of induction therapy cycles was four, again with a trend of increase over the years.At least a very good partial response to induction therapy was achieved more often in the cyclophosphamide, thalidomide, and dexamethasone group (61.1% and in the thalidomide and dexamethasone group (59.2% than in the vincristine, doxorubicin, and dexamethasone group (16.2%. The overall median progression-free survival was 34 months, with no statistically significant difference between the three groups. The overall median survival was not reached, and there was no significant difference between the three groups; the estimated five-year overall survival was 55%. Conclusion: Although the quality of responses appeared to be better with thalidomidecontaining regimens, these improvements did not translate into improved long-term outcomes. Given its track record, cyclophosphamide, thalidomide, and dexamethasone is currently considered the preferred regimen for first-line induction therapy in the

  2. Thermal emitter comprising near-zero permittivity materials

    Science.gov (United States)

    Luk, Ting S.; Campione, Salvatore; Sinclair, Michael B.

    2017-10-25

    A novel thermal source comprising a semiconductor hyperbolic metamaterial provides control of the emission spectrum and the angular emission pattern. These properties arise because of epsilon-near-zero conditions in the semiconductor hyperbolic metamaterial. In particular, the thermal emission is dominated by the epsilon-near-zero effect in the doped quantum wells composing the semiconductor hyperbolic metamaterial. Furthermore, different properties are observed for s and p polarizations, following the characteristics of the strong anisotropy of hyperbolic metamaterials.

  3. The optimal fraction size in high-dose-rate brachytherapy: dependency on tissue repair kinetics and low-dose rate

    International Nuclear Information System (INIS)

    Sminia, Peter; Schneider, Christoph J.; Fowler, Jack F.

    2002-01-01

    Background and Purpose: Indications of the existence of long repair half-times on the order of 2-4 h for late-responding human normal tissues have been obtained from continuous hyperfractionated accelerated radiotherapy (CHART). Recently, these data were used to explain, on the basis of the biologically effective dose (BED), the potential superiority of fractionated high-dose rate (HDR) with large fraction sizes of 5-7 Gy over continuous low-dose rate (LDR) irradiation at 0.5 Gy/h in cervical carcinoma. We investigated the optimal fraction size in HDR brachytherapy and its dependency on treatment choices (overall treatment time, number of HDR fractions, and time interval between fractions) and treatment conditions (reference low-dose rate, tissue repair characteristics). Methods and Materials: Radiobiologic model calculations were performed using the linear-quadratic model for incomplete mono-exponential repair. An irradiation dose of 20 Gy was assumed to be applied either with HDR in 2-12 fractions or continuously with LDR for a range of dose rates. HDR and LDR treatment regimens were compared on the basis of the BED and BED ratio of normal tissue and tumor, assuming repair half-times between 1 h and 4 h. Results: With the assumption that the repair half-time of normal tissue was three times longer than that of the tumor, hypofractionation in HDR relative to LDR could result in relative normal tissue sparing if the optimum fraction size is selected. By dose reduction while keeping the tumor BED constant, absolute normal tissue sparing might therefore be achieved. This optimum HDR fraction size was found to be largely dependent on the LDR dose rate. On the basis of the BED NT/TUM ratio of HDR over LDR, 3 x 6.7 Gy would be the optimal HDR fractionation scheme for replacement of an LDR scheme of 20 Gy in 10-30 h (dose rate 2-0.67 Gy/h), while at a lower dose rate of 0.5 Gy/h, four fractions of 5 Gy would be preferential, still assuming large differences between tumor

  4. Pulsed dose rate and fractionated high dose rate brachytherapy: choice of brachytherapy schedules to replace low dose rate treatments

    International Nuclear Information System (INIS)

    Visser, Andries G.; Aardweg, Gerard J.M.J. van den; Levendag, Peter C.

    1996-01-01

    Purpose: Pulsed dose rate (PDR) brachytherapy is a new type of afterloading brachytherapy (BT) in which a continuous low dose rate (LDR) treatment is simulated by a series of 'pulses,' i.e., fractions of short duration (less than 0.5 h) with intervals between fractions of 1 to a few hours. At the Dr. Daniel den Hoed Cancer Center, the term 'PDR brachytherapy' is used for treatment schedules with a large number of fractions (at least four per day), while the term 'fractionated high dose rate (HDR) brachytherapy' is used for treatment schedules with just one or two brachytherapy fractions per day. Both treatments can be applied as alternatives for LDR BT. This article deals with the choice between PDR and fractionated HDR schedules and proposes possible fractionation schedules. Methods and Materials: To calculate HDR and PDR fractionation schedules with the intention of being equivalent to LDR BT, the linear-quadratic (LQ) model has been used in an incomplete repair formulation as given by Brenner and Hall, and by Thames. In contrast to earlier applications of this model, both the total physical dose and the overall time were not kept identical for LDR and HDR/PDR schedules. A range of possible PDR treatment schedules is presented, both for booster applications (in combination with external radiotherapy (ERT) and for BT applications as a single treatment. Because the knowledge of both α/β values and the half time for repair of sublethal damage (T (1(2)) ), which are required for these calculations, is quite limited, calculations regarding the equivalence of LDR and PDR treatments have been performed for a wide range of values of α/β and T (1(2)) . The results are presented graphically as PDR/LDR dose ratios and as ratios of the PDR/LDR tumor control probabilities. Results: If the condition that total physical dose and overall time of a PDR treatment must be exactly identical to the values for the corresponding LDR treatment regimen is not applied, there appears

  5. Multilayer Electroactive Polymer Composite Material Comprising Carbon Nanotubes

    Science.gov (United States)

    Ounaies, Zoubeida (Inventor); Park, Cheol (Inventor); Harrison, Joycelyn S. (Inventor); Holloway, Nancy M. (Inventor); Draughon, Gregory K. (Inventor)

    2009-01-01

    An electroactive material comprises multiple layers of electroactive composite with each layer having unique dielectric, electrical and mechanical properties that define an electromechanical operation thereof when affected by an external stimulus. For example, each layer can be (i) a 2-phase composite made from a polymer with polarizable moieties and an effective amount of carbon nanotubes incorporated in the polymer for a predetermined electromechanical operation, or (ii) a 3-phase composite having the elements of the 2-phase composite and further including a third component of micro-sized to nano-sized particles of an electroactive ceramic incorporated in the polymer matrix.

  6. High dose rate interstitial brachytherapy with external beam irradiation for localized prostate cancer. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Hiratsuka, Junichi; Jo, Yoshimasa; Yoden, Eisaku; Tanaka, Hiroyoshi; Imajo, Yoshinari [Kawasaki Medical School, Kurashiki, Okayama (Japan); Nagase, Naomi; Narihiro, Naomasa; Kubota, Juichi

    2000-12-01

    This study was undertaken to assess the biochemical and pathological results of combined external beam radiotherapy and high dose rate Ir-192 brachytherapy (HDR-Ir192) for clinically localized prostate cancer. Between October 1997 and August 1999, 39 evaluable patients with adenocarcinoma of prostate diagnosed by biopsy were treated with interstitial and external beam irradiation. Patients ranged in age from 58-82 years, with a mean of 69.7 years. T1c, T2 and T3 tumors, according to the UICC classification system (1997), were found in 7, 21 and 11 cases respectively. The mean initial pre-treatment PSA was 35.9 ng/ml (median 13.2), with 77% of the patients having had a pre-treatment PSA greater than 10 ng/ml. Of all patients, 17 had received pre-treatment hormonal therapy. Hormonal pretreatment was stopped at the beginning of radiotherapy in all cases. External beam four-field box irradiation was given to the small pelvis to a dose of 45 Gy/25 fractions. Three HDR-Ir192 treatments were given over a 30-h period, with 5.5 Gy per fraction at the circumference of the prostate gland over the course of this study. Biochemical failure was defined as a PSA level >1.5 ng/ml and rising on three consecutive values. If serial post-treatment PSA levels showed a continuous downward trend, failure was not scored. The patient with clinical evidence of progression was classified as a clinical failure. The median follow-up at the time of evaluation was 19.6 months. A post-treatment PSA level {<=}1.0 ng/ml was seen in 26 (67%) patients, and values from >1.0 to {<=}2.0 ng/ml were seen in 10 (26%) patients. Biochemical failure was not seen in 38 patients except for one patient who developed a distant bone metastasis with negative prostatic biopsy 15 months after treatment. Biochemical control rate was 100% (38/38) except for the patient with bone metastasis classified as clinical failure. Negative biopsies 18 months after treatment were found in 93% (14/15) of patients. Only one patient

  7. Postoperative vaginal cuff irradiation using high dose rate remote afterloading: a Phase II clinical protocol

    International Nuclear Information System (INIS)

    Noyes, William R.; Bastin, Kenneth; Edwards, Scott A.; Buchler, Dolores A.; Stitt, Judith A.; Thomadsen, Bruce R.; Fowler, Jack F.; Kinsella, Timothy J.

    1995-01-01

    Purpose: In September 1989, a postoperative Phase II high dose rate (HDR) brachytherapy protocol was started for International Federation of Gynecology and Obstetrics (FIGO) Stage I endometrial adenocarcinoma. This review reports the overall survival, local control, and complication rates for the initial 63 patients treated in this Phase II study. Methods and Materials: High dose rate brachytherapy was delivered using an Iridium-192 HDR remote afterloader. Sixty-three patients were entered into the Phase II protocol, each receiving two vaginal cuff treatments 1 week apart (range 4-12 days) with vaginal ovoids (diameter 2.0-3.0 cm). No patient received adjuvant external beam radiation. A dose of 32.4 Gy in two fractions was prescribed to the ovoid surface in 63 patients. The first three patients treated at our institution received 15, 16.2, and 29 Gy, respectively, to determine acute effects. Results: At a median follow-up of 1.6 years (range 0.75-4.3 years) no patient has developed a vaginal cuff recurrence. One regional recurrence (1.6%) occurred at 1.2 years at the pelvic side wall. This patient is alive and without evidence of disease 7 months after completion of salvage irradiation, which resulted in the only vaginal stenosis (1.6%). Fourteen patients (22%) experienced vaginal apex fibrosis by physical exam, which was clinically symptomatic in four patients. Two patients reported stress incontinence; however, these symptoms were noted prior to their HDR therapy. One patient died 2.4 years after HDR therapy due to cardiovascular disease without evidence of cancer at autopsy. Conclusion: Preliminary results of our phase II HDR vaginal cuff protocol for postoperative FIGO Stage IA, Grade 3 or Stage IB, Grade 1-2 patients demonstrate that 32.4 Gy in two fractions is well tolerated by the vaginal cuff mucosa. Local control appears comparable to our prior experience and others with low dose rate (LDR) brachytherapy. Additional patient accrual and further follow

  8. High-dose benzodiazepine dependence: a qualitative study of patients' perception on cessation and withdrawal.

    Science.gov (United States)

    Liebrenz, Michael; Gehring, Marie-Therese; Buadze, Anna; Caflisch, Carlo

    2015-05-13

    Benzodiazepine withdrawal syndrome has been reported following attempts to withdraw even from low or therapeutic doses and has been compared to barbiturate and alcohol withdrawal. This experience is known to deter patients from future cessation attempts. Research on other psychotropic substances shows that the reasons and motivations for withdrawal attempts - as well as the experiences surrounding those attempts - at least partially predict future efforts at discontinuation as well as relapse. We therefore aimed to qualitatively explore what motivates patients to discontinue this medication as well as to examine their experiences surrounding previous and current withdrawal attempts and treatment interventions in order to positively influence future help-seeking behavior and compliance. To understand these patients better, we conducted a series of 41 unstructured, narrative, in-depth interviews among adult Swiss patients with a long-term dependent use of benzodiazepines in doses equivalent to more than 40 mg diazepam per day and/or otherwise problematic use (mixing benzodiazepines, escalating dosage, recreational use or illegal purchase). Mayring's qualitative content analysis was used to evaluate findings. These high-dose benzodiazepine-dependent patients decision to change consumption patterns were affected by health concerns, the feeling of being addicted and social factors. Discontinuation attempts were frequent and not very successful with fast relapse. Withdrawal was perceived to be a difficult, complicated, and highly unpredictable process. The first attempt at withdrawal occurred at home and typically felt better than at the clinic. Inpatient treatment was believed to be more effective with long term treatment (approaches) than short term. Patients preferred gradual reduction of usage to abrupt cessation (and had experienced both). While no clear preferences for withdrawal were found for benzodiazepines with specific pharmacokinetic properties, participants

  9. Practice of superselective intraarterial high-dose cisplatin chemoradiotherapy in the oral cavity

    International Nuclear Information System (INIS)

    Yoshida, Tomoyuki; Nakamura, Kazuhiro; Tsukahara, Kiyoaki; Inagaki, Taro; Ito, Hiroyuki; Shimizu, Akira; Takata, Daisuke; Okamoto, Isaku; Kondo, Takahito

    2011-01-01

    Superselective intraarterial infusion enables high-dose chemotherapeutic agents to be administered via tumor feeding vessels to neutralize and limit the adverse cisplatin effects acceptable. Between 1998 and 2008, we evaluated the efficacy of first-line therapy and adverse events in 30 subjects with oral squamous cell cancer undergoing simultaneous superselective intra arterial high-dose chemotherapy and radiotherapy. The 30 subjects- 23 men and 7 women aged 40 to 72- consisted of 3 T2, 12 T3, and 15 T4. Four patients had N0, 8 N1, 7 N2b, 8 N2c, and 3 N3 disease. Two were in CS II, 6 III, 17 IVa, and 5 IVb (III>93%, IV: 73%). Superselective intra arterial chemotherapy delivered through the femoral artery used the Seldinger technique. A single cisplatin dose of 100-550 mg/m 2 (mean 440 mg/m 2 ). Five minutes after intra arterial infusion, sodium thiosulphate (9 g/m 2 ) was administered via a peripheral cutaneous vein in the contralateral forearm. Concurrent radiotherapy started on Day 2 at 2 Gy per session for a total of 60 Gy. Two to 3 weeks later, 15 under went the second course of superselective intra arterial chemotherapy after tumor feeding vessels were visualized angiographically. Four (13.3%) subjects with Grade 3 or greater myelosuppression required granulocyte-colony stimulating factor (G-CSF). Grade 3 or greater mucositis was observed in 57% and Grade 4 mucositis occurred in 5 (16.7%). All adverse effects were reversible and no serious adverse events were prolonged. Among those responding to first-line therapy, 24 of the 30 (80%) achieved complete response (CR) and 6 (20%) partial response (PR), but no stable disease (SD) or no change (NC). Overall response was 100%. Histopathologically, 2 of 9 undergoing postchemoradiotherapy had no tumors. Clinical and pathological CR was 86.7%. Adverse events associated with this therapy associated events were considered relatively mild and within allowable limits. (author)

  10. Mechanisms of Fatal Cardiotoxicity following High-Dose Cyclophosphamide Therapy and a Method for Its Prevention.

    Directory of Open Access Journals (Sweden)

    Takuro Nishikawa

    Full Text Available Observed only after administration of high doses, cardiotoxicity is the dose-limiting effect of cyclophosphamide (CY. We investigated the poorly understood cardiotoxic mechanisms of high-dose CY. A rat cardiac myocardial cell line, H9c2, was exposed to CY metabolized by S9 fraction of rat liver homogenate mixed with co-factors (CYS9. Cytotoxicity was then evaluated by 3-(4,5-dimethyl-2-thiazolyl¬2,5-diphenyl¬2H-tetrazolium bromide (MTT assay, lactate dehydrogenase release, production of reactive oxygen species (ROS, and incidence of apoptosis. We also investigated how the myocardial cellular effects of CYS9 were modified by acrolein scavenger N-acetylcysteine (NAC, antioxidant isorhamnetin (ISO, and CYP inhibitor β-ionone (BIO. Quantifying CY and CY metabolites by means of liquid chromatography coupled with electrospray tandem mass spectrometry, we assayed culture supernatants of CYS9 with and without candidate cardioprotectant agents. Assay results for MTT showed that treatment with CY (125-500 μM did not induce cytotoxicity. CYS9, however, exhibited myocardial cytotoxicity when CY concentration was 250 μM or more. After 250 μM of CY was metabolized in S9 mix for 2 h, the concentration of CY was 73.6 ± 8.0 μM, 4-hydroxy-cyclophosphamide (HCY 17.6 ± 4.3, o-carboxyethyl-phosphoramide (CEPM 26.6 ± 5.3 μM, and acrolein 26.7 ± 2.5 μM. Inhibition of CYS9-induced cytotoxicity occurred with NAC, ISO, and BIO. When treated with ISO or BIO, metabolism of CY was significantly inhibited. Pre-treatment with NAC, however, did not inhibit the metabolism of CY: compared to control samples, we observed no difference in HCY, a significant increase of CEPM, and a significant decrease of acrolein. Furthermore, NAC pre-treatment did not affect intracellular amounts of ROS produced by CYS9. Since acrolein seems to be heavily implicated in the onset of cardiotoxicity, any competitive metabolic processing of CY that reduces its transformation to acrolein

  11. Implementation of High-Dose-Rate Brachytherapy and Androgen Deprivation in Patients With Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lilleby, Wolfgang, E-mail: wolfgang.lilleby@ous-hf.no [Cancer Clinic, Oslo University Hospital, Norwegian Radiumhospital, Department of Radiotherapy and Oncology, Oslo (Norway); Tafjord, Gunnar; Raabe, Nils K. [Cancer Clinic, Oslo University Hospital, Norwegian Radiumhospital, Department of Radiotherapy and Oncology, Oslo (Norway)

    2012-07-01

    Purpose: To evaluate outcome (overall survival [OS], the actuarial 5-year cancer-specific survival [CSS], disease-free survival [DFS], biochemical failure-free survival [BFS]), complications and morbidity in patients treated with high-dose-rate brachytherapy (HDR-BT) boost and hormonal treatment with curative aims. Methods: Between 2004 and 2009, 275 prospectively followed pN0/N0M0 patients were included: 19 patients (7%) with T2, Gleason score 7 and prostate-specific antigen (PSA) <10 and 256 patients (93%) with T3 or Gleason score 8-10 or PSA >20 received multimodal treatment with conformal four-field radiotherapy (prostate/vesiculae 2 Gy Multiplication-Sign 25) combined with HDR-BT (iridium 192; prostate 10 Gy Multiplication-Sign 2) with long-term androgen deprivation therapy (ADT). Results: After a median observation time of 44.2 months (range, 10.4-90.5 months) 12 patients had relapsed clinically and/or biochemically and 10 patients were dead, of which 2 patients died from prostate cancer. Five-year estimates of BFS, CSS, DFS, and OS rates were 98.5%, 99.3%, 95.6%, and 96.3%, respectively. None of the patients with either Gleason score <8 or with intermediate risk profile had relapsed. The number of HDR-BT treatments was not related to outcome. Despite of age (median, 65.7 years; range, 45.7-77 years) and considerable pretreatment comorbidity in 39 of 275 patients, Genitourinary treatment-related morbidity was moderate with long-lasting Radiation Therapy Oncology Group Grade 2 voiding problems in 26 patients (9.5%) and occasionally mucous discharge in 20 patients (7%), none with Grade >2 for gastrointestinal at follow-up. Complications during implantations were related to pubic arch interference (4 patients) and lithotomy time, causing 2 patients to develop compartment syndrome. Conclusion: Despite still preliminary observations, our 5-year outcome estimates favor the implementation of high-dose-rate brachytherapy in high-risk patients combined with conformal

  12. Characterization of silicates and calcium carbonates applied to high-dose dosimetry

    International Nuclear Information System (INIS)

    Vila, Gustavo Barreto

    2012-01-01

    The predominant isomorphous form in the biominerals studied in this work (oyster shell, coral, mother of pearl and shell) was aragonite. The appearance of the calcite phase occurred at 500 deg C at a heating rate of 10 deg C /s for all samples except for the coral sample, which was 400 deg C, independent of the heating rate. The most abundant element in the biominerals samples was Ca in the CaO form, and in the silicates (tremolite, diopside and rhodonite) Si in the SiO form. The most common trace element observed in the biominerals samples was Fe. The analyses of electron paramagnetic resonance showed lines of Mn 2+ in the coral and mother-of-pearl samples before irradiation. In the case of the irradiated samples, the defects found were CO 2 - , CO 3 3- , CO 3 - and SO 2 - , in the g range between 2.0010 and 2.0062. In the analyses by optical absorption of biominerals, transitions due to the presence of Mn in the samples were found. A thermoluminescent (TL) peak at approximately 140 deg C was found for the biominerals and at 180 deg C for silicates, which intensity depends directly on the dose. For samples exposed to different types of radiation, the TL peak occurred at lower temperatures. From the dose-response curves obtained for these materials, it was possible to determine a linear range for which their application in high dose dosimetry becomes possible. Taking into account the radiation type, among biominerals and silicates, the lowest detectable dose (40mGy) to gamma radiation was achieved for oyster shell samples using the measuring technique of optically stimulated luminescence (OSL). Using beta radiation, for diopside and tremolite samples the lowest detectable dose of 60mGy was obtained. For all samples, using the TL, OSL and thermally stimulated exoelectron emission (TSEE) techniques in alpha, beta and gamma radiation beans a good response reproducibility was obtained. Therefore, the samples characterized in this work are suitable to be used as high

  13. Esophageal Toxicity From High-Dose, Single-Fraction Paraspinal Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Cox, Brett W.; Jackson, Andrew; Hunt, Margie; Bilsky, Mark; Yamada, Yoshiya

    2012-01-01

    Purpose: To report the esophageal toxicity from single-fraction paraspinal stereotactic radiosurgery (SRS) and identify dosimetric and clinical risk factors for toxicity. Methods and Materials: A total of 204 spinal metastases abutting the esophagus (182 patients) were treated with high-dose single-fraction SRS during 2003-2010. Toxicity was scored using the National Cancer Institute Common Toxicity Criteria for Adverse Events, version 4.0. Dose-volume histograms were combined to generate a comprehensive atlas of complication incidence that identifies risk factors for toxicity. Correlation of dose-volume factors with esophageal toxicity was assessed using Fisher’s exact test and logistic regression. Clinical factors were correlated with toxicity. Results: The median dose to the planning treatment volume was 24 Gy. Median follow-up was 12 months (range, 3-81). There were 31 (15%) acute and 24 (12%) late esophageal toxicities. The rate of grade ≥3 acute or late toxicity was 6.8% (14 patients). Fisher’s exact test resulted in significant median splits for grade ≥3 toxicity at V12 = 3.78 cm 3 (relative risk [RR] 3.7, P=.05), V15 = 1.87 cm 3 (RR 13, P=.0013), V20 = 0.11 cm 3 (RR 6, P=0.01), and V22 = 0.0 cm 3 (RR 13, P=.0013). The median split for D2.5 cm 3 (14.02 Gy) was also a significant predictor of toxicity (RR 6; P=.01). A highly significant logistic regression model was generated on the basis of D2.5 cm 3 . One hundred percent (n = 7) of grade ≥4 toxicities were associated with radiation recall reactions after doxorubicin or gemcitabine chemotherapy or iatrogenic manipulation of the irradiated esophagus. Conclusions: High-dose, single-fraction paraspinal SRS has a low rate of grade ≥3 esophageal toxicity. Severe esophageal toxicity is minimized with careful attention to esophageal doses during treatment planning. Iatrogenic manipulation of the irradiated esophagus and systemic agents classically associated with radiation recall reactions are

  14. High-dose regions versus likelihood of cure after prostate brachytherapy

    International Nuclear Information System (INIS)

    Wallner, Kent; Merrick, Gregory; Sutlief, Steven; True, Laurence; Butler, Wayne

    2005-01-01

    Purpose: To analyze the effect of high-dose regions on biochemical cancer control rates after prostate brachytherapy. Methods and Materials: Patients with 1997 American Joint Committee on Cancer clinical Stage T1c-T2a prostate carcinoma (Gleason grade 5-6, prostate-specific antigen level 4-10 ng/mL) were randomized to implantation with 125 I (144 Gy) vs. 103 Pd (125 Gy, National Institute of Standards and Technology 1999). Isotope implantation was performed by standard techniques, using a modified peripheral loading pattern. Of the 313 patients entered in the protocol, 270 were included in this analysis. The 125 I source strength ranged from 0.4 to 0.89 mCi (median, 0.55 mCi), and the 103 Pd source strength ranged from 1.3 to 1.6 mCi (median, 1.5 mCi). CT was performed within 4 h after implantation. The dosimetric parameters analyzed included the percentage of the postimplant prostate volume covered by the 100%, 150%, 200%, and 300% prescription dose (V 100 , V 150 , V 200 , and V 300 , respectively). The median time to the last follow-up for patients without failure was 2.7 years. Freedom from biochemical failure was defined as a serum prostate-specific antigen level of ≤0.5 ng/mL at last follow-up. Patients were censored at last follow-up if their serum prostate-specific antigen level was still decreasing. Results: The mean V 100 , V 150 , V 200 , and V 300 value was 90% (±8%), 63% (±14), 35% (±13%), and 14% (±7%), respectively. Patients with a V 100 of ≥90% had a 3-year freedom from biochemical failure rate of 96% vs. 87% for those with a V 100 of 100 of ≥90% were analyzed, no relationship was found between higher dose regions and the likelihood of cancer control. This lack of effect on biochemical control was apparent for both isotopes. Conclusion: High-dose regions do not appear to affect cancer control rates, as long as >90% of the prostate volume is covered by the prescription dose

  15. Radiobiological aspects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation

    International Nuclear Information System (INIS)

    Turesson, I.

    1990-01-01

    The biological effects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation in interstitial and intracavitary radiotherapy and total body irradiation are discussed in terms of dose-rate fractionation sensitivity for various tissues. A scaling between dose-rate and fraction size was established for acute and late normal-tissue effects which can serve as a guideline for local treatment in the range of dose rates between 0.02 and 0.005 Gy/min and fraction sizes between 8.5 and 2.5 Gy. This is valid provided cell-cycle progression and proliferation can be ignored. Assuming that the acute and late tissue responses are characterized by α/β values of about 10 and 3 Gy and a mono-exponential repair half-time of about 3 h, the same total doses given with either of the two methods are approximately equivalent. The equivalence for acute and late non-hemopoietic normal tissue damage is 0.02 Gy/min and 8.5 Gy per fraction; 0.01 Gy/min and 5.5 Gy per fraction; and 0.005 Gy/min and 2.5Gy per fraction. A very low dose rate, below 0.005 Gy/min, is thus necessary to simulate high dose-rate radiotherapy with fraction sizes of about 2Gy. The scaling factor is, however, dependent on the repair half-time of the tissue. A review of published data on dose-rate effects for normal tissue response showed a significantly stronger dose-rate dependence for late than for acute effects below 0.02 Gy/min. There was no significant difference in dose-rate dependence between various acute non-hemopoietic effects or between various late effects. The consistent dose-rate dependence, which justifies the use of a general scaling factor between fraction size and dose rate, contrasts with the wide range of values for repair half-time calculated for various normal-tissue effects. This indicates that the model currently used for repair kinetics is not satisfactory. There are also few experimental data in the clinical dose-rate range, below 0.02 Gy/min. It is therefore

  16. Development of a dosimeter for high doses assessment based on Alanine/EPR

    International Nuclear Information System (INIS)

    Galante, O.L.; Rodrigues, O. Jr.; Campos, L.L.

    2000-01-01

    The increasing use of radiation sources of high activity for industrial and medical applications becomes important the research and the development of detectors and dosimetric methods for quality control of the applied doses. This work presents the current stage of the research at IPEN/CNEN-SP that has as objective the development of a standard dosimetric system for high doses assessment based on the alanine as radiation detector and electron paramagnetic resonance (EPR) as measurement technique. The developed system consists of the cylindrical container built in polyethylene of high density and the detector element based on DL-alanine commercially available. For the detector preparation different binding materials such as paraffin and acetate polyvinyl solution (pva) and also the use of a polyethylene tube of low density with 3.2 mm of external diameter, 2 mm of internal diameter and 30 mm of length were tested to provide the easier preparation method and the most sensitive detector. For the alanine + paraffin detector it was used 80% of alanine and 20% of paraffin, for the alanine + pva detector it was used 70% of alanine and 30% of pva solution, and pure alanine was encapsulated, compacted and sealed in the case of the polyethylene tube. The obtained results with respect to handling, packing and construction easiness showed that the polyethylene tube presents all characteristics to obtain of a good detector element. The validation of the dosimetric system was carried out with gamma radiation of the cobalt-60 with doses in the range between 0.2 Gy to 200 kGy. Type tests such as fading, lowest detection limit, reproducibility and energy dependence of the sign EPR were performed. All measurements were carried out at room temperature using a spectrometer of electron paramagnetic resonance (EPR) Bruker model MXE. Taking into account the results obtained: linearity of the EPR signal between 10 Gy and 50 kGy, reproducibility better than 3%, low fading associated with

  17. Developing A Directional High-Dose Rate (d-HDR) Brachytherapy Source

    Science.gov (United States)

    Heredia, Athena Yvonne

    Conventional sources used in brachytherapy provide nearly isotropic or radially symmetric dose distributions. Optimizations of dose distributions have been limited to varied dwell times at specified locations within a given treatment volume, or manipulations in source position for seed implantation techniques. In years past, intensity modulated brachytherapy (IMBT) has been used to reduce the amount of radiation to surrounding sensitive structures in select intracavitary cases by adding space or partial shields. Previous work done by Lin et al., at the University of Wisconsin-Madison, has shown potential improvements in conformality for brachytherapy treatments using a directionally shielded low dose rate (LDR) source for treatments in breast and prostate. Directional brachytherapy sources irradiate approximately half of the radial angles around the source, and adequately shield a quarter of the radial angles on the opposite side, with sharp gradient zones between the treated half and shielded quarter. With internally shielded sources, the radiation can be preferentially emitted in such a way as to reduce toxicities in surrounding critical organs. The objective of this work is to present findings obtained in the development of a new directional high dose rate (d-HDR) source. To this goal, 103Pd (Z = 46) is reintroduced as a potential radionuclide for use in HDR brachytherapy. 103Pd has a low average photon energy (21 keV) and relatively short half -life (17 days), which is why it has historically been used in low dose rate applications and implantation techniques. Pd-103 has a carrier-free specific activity of 75000 Ci/g. Using cyclotron produced 103Pd, near carrier-free specific activities can be achieved, providing suitability for high dose rate applications. The evolution of the d-HDR source using Monte Carlo simulations is presented, along with dosimetric parameters used to fully characterize the source. In addition, a discussion on how to obtain elemental

  18. High-dose preoperative radiation for cancer of the rectum: Impact of radiation dose on patterns of failure and survival

    International Nuclear Information System (INIS)

    Ahmad, N.R.; Mohiuddin, M.; Marks, G.

    1993-01-01

    A variety of dose-time schedules are currently used for preoperative radiation therapy of rectal cancer. An analysis of patients treated with high-dose preoperative radiation therapy was undertaken to determine the influence of radiation dose on the patterns of failure, survival, and complications. Two hundred seventy-five patients with localized rectal cancer were treated with high-dose preoperative radiation therapy. One hundred fifty-six patients received 45 Gy (low-dose group). Since 1985, 119 patients with clinically unfavorable cancers were given a higher dose, 55 Gy using a shrinking field technique (high-dose group). All patients underwent curative resection. Median follow-up was 66 months in the low-dose group and 28 months in the high-dose group. Patterns of failure, survival, and complications were analyzed as a function of radiation dose. Fourteen percent of the total group developed a local recurrence; 20% in the low-dose group as compared with 6% in the high-dose group. The actuarial local recurrence rate at 5 years was 20% for the low-dose group and 8% for the high-dose group, and approached statistical significance with p = .057. For tethered/fixed tumors the actuarial local recurrence rates at 5 years were 28% and 9%, respectively, with p = .05. Similarly, for low-lying tumors (less than 6 cm from the anorectal junction) the rates were 24% and 9%, respectively, with p = .04. The actuarial rate of distant metastasis was 28% in the low-dose group and 20% in the high-dose group and was not significantly different. Overall actuarial 5-year survival for the total group of patients was 66%. No significant difference in survival was observed between the two groups, despite the higher proportion of unfavorable cancers in the high-dose group. The incidence of complications was 2%, equally distributed between the two groups. High-dose preoperative radiation therapy for rectal cancer results in excellent local control rates. 27 refs., 2 figs., 8 tabs

  19. A chromogranin A ELISA absent of an apparent high-dose hook effect observed in other chromogranin A ELISAs.

    Science.gov (United States)

    Erickson, J Alan; Grenache, David G

    2016-01-15

    Routine testing for chromogranin A (CgA) using an established commercial ELISA revealed an apparent high-dose hook effect in approximately 15% of specimens. Investigations found the same effect in two additional ELISAs. We hypothesized that a CgA derived peptide(s) at high concentrations was responsible but experiments were inconclusive. Here we describe the analytical performance characteristics of the Chromoa™ CgA ELISA that did not display the apparent high-dose hook effect. Performance characteristics of the Chromoa ELISA were assessed. The reference interval was established utilizing healthy volunteers. Specimens producing the apparent high-dose hook effect in other assays were evaluated using the Chromoa ELISA. The limit of detection was 8ng/ml. Linearity was acceptable (slope=1.04, intercept=18.1 and r(2)=0.997). CVs were ≤4.6 and ≤9.3% for repeatability and within-laboratory imprecision, respectively. CgA was stable at ambient and refrigerated temperatures for a minimum of two and 14days, respectively. An upper reference interval limit of 95ng/ml was established. Specimens demonstrating the apparent high-dose hook effect in other ELISAs did not exhibit the phenomenon using the Chromoa ELISA. The Chromoa ELISA demonstrates acceptable performance for quantifying serum CgA. The apparent high-dose hook effect exhibited in other ELISAs was absent using the Chromoa assay. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. High-dose ibuprofen therapy associated with esophageal ulceration after pneumonectomy in a patient with cystic fibrosis: a case report

    Directory of Open Access Journals (Sweden)

    Anbar Ran D

    2004-09-01

    Full Text Available Abstract Background Lung disease in patients with cystic fibrosis is thought to develop as a result of airway inflammation, infection, and obstruction. Pulmonary therapies for cystic fibrosis that reduce airway inflammation include corticosteroids, rhDNase, antibiotics, and high-dose ibuprofen. Despite evidence that high-dose ibuprofen slows the progression of lung disease in patients with cystic fibrosis, many clinicians have chosen not to use this therapy because of concerns regarding potential side effects, especially gastrointestinal bleeding. However, studies have shown a low incidence of gastrointestinal ulceration and bleeding in patients with cystic fibrosis who have been treated with high-dose ibuprofen. Case presentation The described case illustrates a life-threatening upper gastrointestinal bleed that may have resulted from high-dose ibuprofen therapy in a patient with CF who had undergone a pneumonectomy. Mediastinal shift post-pneumonectomy distorted the patient's esophageal anatomy and may have caused decreased esophageal motility, which led to prolonged contact of the ibuprofen with the esophagus. The concentrated effect of the ibuprofen, as well as its systemic effects, probably contributed to the occurrence of the bleed in this patient. Conclusions This report demonstrates that gastrointestinal tract anatomical abnormalities or dysmotility may be contraindications for therapy with high-dose ibuprofen in patients with cystic fibrosis.

  1. Photovoltaic device comprising compositionally graded intrinsic photoactive layer

    Science.gov (United States)

    Hoffbauer, Mark A; Williamson, Todd L

    2013-04-30

    Photovoltaic devices and methods of making photovoltaic devices comprising at least one compositionally graded photoactive layer, said method comprising providing a substrate; growing onto the substrate a uniform intrinsic photoactive layer having one surface disposed upon the substrate and an opposing second surface, said intrinsic photoactive layer consisting essentially of In.sub.1-xA.sub.xN,; wherein: i. 0.ltoreq.x.ltoreq.1; ii. A is gallium, aluminum, or combinations thereof; and iii. x is at least 0 on one surface of the intrinsic photoactive layer and is compositionally graded throughout the layer to reach a value of 1 or less on the opposing second surface of the layer; wherein said intrinsic photoactive layer is isothermally grown by means of energetic neutral atom beam lithography and epitaxy at a temperature of 600.degree. C. or less using neutral nitrogen atoms having a kinetic energy of from about 1.0 eV to about 5.0 eV, and wherein the intrinsic photoactive layer is grown at a rate of from about 5 nm/min to about 100 nm/min.

  2. Whole-brain radiotherapy and high-dose methylprednisolone for elderly patients with primary central nervous system lymphoma: Results of North Central Cancer Treatment Group (NCCTG) 96-73-51

    International Nuclear Information System (INIS)

    Laack, Nadia N.; Ballman, Karla V.; Brown, Paul B.; O'Neill, Brian Patrick

    2006-01-01

    Purpose: The aim of this study was to evaluate the efficacy, toxicity, and survival of whole-brain radiotherapy-treated (WBRT) and high-dose methylprednisolone (HDMP)-treated in elderly patients with primary central nervous system lymphoma (PCNSL). Methods and Materials: Patients with PCNSL who were 70 years and older received 1 g of methylprednisolone daily for 5 days, 30 days after WBRT. Patients then received 1 g of methylprednisolone every 28 days until progression. The primary endpoint was overall survival (OS) at 6 months. Results were compared with those in patients on the previous North Central Cancer Treatment Group (NCCTG) trial who received pre-WBRT cytoxan, adriamycin, vincristine, prednisone (CHOP) and high-dose cytarabine (CHOP-WBRT). A planned interim analysis was performed. The current regimen would be considered inactive if survival was not improved from patients treated with CHOP-WBRT. Results: Nineteen patients were accrued between 1998 and 2003. Median age was 76 years. Interim analysis revealed a 6-month survival of 33%, resulting in closure of the trial. Toxicity, OS, and event-free survival (EFS) were similar to those in patients more than 70 years of age who received CHOP-WBRT. The subgroup of patients who received HDMP had longer OS (12.1 vs. 7.0 months, p = 0.76) and EFS (11.7 vs. 4.0 months, p = 0.04) compared with the CHOP-WBRT patients alive 60 days after the start of treatment. Conclusions: Patients on-study long enough to receive HDMP had prolongation of OS and EFS compared to patients receiving CHOP-WBRT. Although the numbers of patients are too small for statistical conclusions, the HDMP regimen deserves further study

  3. Novel Use of the Contura for High Dose Rate Cranial Brachytherapy

    International Nuclear Information System (INIS)

    Scanderbeg, Daniel J.; Alksne, John F.; Lawson, Joshua D.; Murphy, Kevin T.

    2011-01-01

    A popular choice for treatment of recurrent gliomas was cranial brachytherapy using the GliaSite Radiation Therapy System. However, this device was taken off the market in late 2008, thus leaving a treatment void. This case study presents our experience treating a cranial lesion for the first time using a Contura multilumen, high-dose-rate (HDR) brachytherapy balloon applicator. The patient was a 47-year-old male who was diagnosed with a recurrent right frontal anaplastic oligodendroglioma. Previous radiosurgery made him a good candidate for brachytherapy. An intracavitary HDR balloon brachytherapy device (Contura) was placed in the resection cavity and treated with a single fraction of 20 Gy. The implant, treatment, and removal of the device were all completed without incident. Dosimetry of the device was excellent because the dose conformed very well to the target. V90, V100, V150, and V200 were 98.9%, 95.7%, 27.2, and 8.8 cc, respectively. This patient was treated successfully using the Contura multilumen balloon. Contura was originally designed for deployment in a postlumpectomy breast for treatment by accelerated partial breast irradiation. Being an intracavitary balloon device, its similarity to the GliaSite system makes it a viable replacement candidate. Multiple lumens in the device also make it possible to shape the dose delivered to the target, something not possible before with the GliaSite applicator.

  4. High-Dose Neutron Detector Development Using 10B Coated Cells

    Energy Technology Data Exchange (ETDEWEB)

    Menlove, Howard Olsen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Henzlova, Daniela [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-11-08

    During FY16 the boron-lined parallel-plate technology was optimized to fully benefit from its fast timing characteristics in order to enhance its high count rate capability. To facilitate high count rate capability, a novel fast amplifier with timing and operating properties matched to the detector characteristics was developed and implemented in the 8” boron plate detector that was purchased from PDT. Each of the 6 sealed-cells was connected to a fast amplifier with corresponding List mode readout from each amplifier. The FY16 work focused on improvements in the boron-10 coating materials and procedures at PDT to significantly improve the neutron detection efficiency. An improvement in the efficiency of a factor of 1.5 was achieved without increasing the metal backing area for the boron coating. This improvement has allowed us to operate the detector in gamma-ray backgrounds that are four orders of magnitude higher than was previously possible while maintaining a relatively high counting efficiency for neutrons. This improvement in the gamma-ray rejection is a key factor in the development of the high dose neutron detector.

  5. Solid ferrous ammonium sulfate as a dosimeter at low temperatures and high doses

    International Nuclear Information System (INIS)

    Juarez-calderon, J.M.; Ramos B, S.; Negron M, A.

    2006-01-01

    This paper presents the results obtained from a study of the radiation induced oxidation of crystalline ferrous ammonium sulfate with gamma rays at 295 K, 263 K and 77 K and doses from 0 to 300 kGy. The radiation induced decomposition of ferrous ammonium sulfate has been studied by the dissolution of the irradiated salt in 0,8 N sulfuric acid. The main product is ferric ion (Fe 3+ ) and its molar concentration was determined spectrophotometrically in the UV region at 304 nm. The optical density values showed a linear dependence with dose, indicating that the data obtained might be used to create a calibrating curve. Color in irradiated salt changes from blue to green, yellow and orange according to the absorbed dose. The accuracy and the reproducibility of the system were tested. In addition, some other characteristics make possible the use of this system as a dosimeter, similar to Fricke chemical dosimeter, for studies and works at low temperatures and high doses. (authors)

  6. Expected cost effectiveness of high-dose trivalent influenza vaccine in US seniors.

    Science.gov (United States)

    Chit, Ayman; Roiz, Julie; Briquet, Benjamin; Greenberg, David P

    2015-01-29

    Seniors are particularly vulnerable to complications resulting from influenza infection. Numerous influenza vaccines are available to immunize US seniors, and practitioners must decide which product to use. Options include trivalent and quadrivalent standard-dose inactivated influenza vaccines (IIV3 and IIV4 respectively), as well as a high-dose IIV3 (HD). Our research examines the public health impact, budget impact, and cost-utility of HD versus IIV3 and IIV4 for immunization of US seniors 65 years of age and older. Our model was based on US influenza-related health outcome data. Health care costs and vaccine prices were obtained from the Centers for Medicare and Medicaid Services. Efficacies of IIV3 and IIV4 were estimated from various meta-analyses of IIV3 efficacy. The results of a head-to-head randomized controlled trial of HD vs. IIV3 were used to estimate relative efficacy of HD. Conservatively, herd protection was not considered. Compared to IIV3, HD would avert 195,958 cases of influenza, 22,567 influenza-related hospitalizations, and 5423 influenza-related deaths among US seniors. HD generates 29,023 more Quality Adjusted Life Years (QALYs) and a net societal budget impact of $154 million. The Incremental Cost Effectiveness Ratio (ICER) for this comparison is $5299/QALY. 71% of the probabilistic sensitivity analysis (PSA) simulations were seniors. Our conclusions were robust in the face of sensitivity analyses. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. [A Quality Assurance (QA) System with a Web Camera for High-dose-rate Brachytherapy].

    Science.gov (United States)

    Hirose, Asako; Ueda, Yoshihiro; Oohira, Shingo; Isono, Masaru; Tsujii, Katsutomo; Inui, Shouki; Masaoka, Akira; Taniguchi, Makoto; Miyazaki, Masayoshi; Teshima, Teruki

    2016-03-01

    The quality assurance (QA) system that simultaneously quantifies the position and duration of an (192)Ir source (dwell position and time) was developed and the performance of this system was evaluated in high-dose-rate brachytherapy. This QA system has two functions to verify and quantify dwell position and time by using a web camera. The web camera records 30 images per second in a range from 1,425 mm to 1,505 mm. A user verifies the source position from the web camera at real time. The source position and duration were quantified with the movie using in-house software which was applied with a template-matching technique. This QA system allowed verification of the absolute position in real time and quantification of dwell position and time simultaneously. It was evident from the verification of the system that the mean of step size errors was 0.31±0.1 mm and that of dwell time errors 0.1±0.0 s. Absolute position errors can be determined with an accuracy of 1.0 mm at all dwell points in three step sizes and dwell time errors with an accuracy of 0.1% in more than 10.0 s of the planned time. This system is to provide quick verification and quantification of the dwell position and time with high accuracy at various dwell positions without depending on the step size.

  8. Microstructural evolution in low alloy steels under high dose ion irradiation

    International Nuclear Information System (INIS)

    Fujii, Katsuhiko; Fukuya, Koji; Ohkubo, Tadakatsu; Hono, Kazuhiro

    2006-01-01

    Radiation hardening and microstructural evolution in low Cu A533B steels (0.03 wt% Cu) irradiated by 3 MeV Ni 2+ ions at 290degC to 1 dpa were investigated by ultra-micro hardness measurement and leaser type three dimensional atom probe analysis. Mn-Ni-Si enriched precipitates were detected in the samples irradiated to 1 dpa by 3DAP analysis. The well-defined precipitates had a size of less than 4 nm, and the number density increased with dose. The formation of the precipitates under high dose rate irradiation suggested that Mn-Ni-Si enriched precipitates were formed by a process such as radiation induced precipitation rather than by thermal equilibrium process. The increase of yield stress calculated by size and number density of the precipitates in 1 dpa irradiated sample using the similar value of hardening efficiency to that of Cu rich precipitates was consistent with that estimated by data of increases of hardness measured by nano-indentation. The result indicates that effects of Mn-Ni-Si enriched precipitates on radiation embrittlement are similar to those of Cu rich precipitates. (author)

  9. Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source

    International Nuclear Information System (INIS)

    Sarabiasl, Akbar; Ayoobian, Navid; Jabbari, Iraj; Poorbaygi, Hossein; Javanshir, Mohammad Reza

    2016-01-01

    High-dose-rate (HDR) brachytherapy is a common method for cancer treatment in clinical brachytherapy. Because of the different source designs, there is a need for specific dosimetry data set for each HDR model. The purpose of this study is to obtain detailed dose rate distributions in water phantom for a first prototype HDR 192 Ir brachytherapy source model, IRAsource, and compare with the other published works. In this study, Monte Carlo N-particle (MCNP version 4C) code was used to simulate the dose rate distributions around the HDR source. A full set of dosimetry parameters reported by the American Association of Physicists in Medicine Task Group No. 43U1 was evaluated. Also, the absorbed dose rate distributions in water, were obtained in an along-away look-up table. The dose rate constant, Λ, of the IRAsource was evaluated to be equal to 1.112 ± 0.005 cGy h −1 U −1 . The results of dosimetry parameters are presented in tabulated and graphical formats and compared with those reported from other commercially available HDR 192 Ir sources, which are in good agreement. This justifies the use of specific data sets for this new source. The results obtained in this study can be used as input data in the conventional treatment planning systems.

  10. Estimation of the transit dose component in high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Garcia Romero, A.; Millan Cebrian, E.; Lozano Flores, F.J.; Lope Lope, R.; Canellas Anoz, M.

    2001-01-01

    Current high dose rate brachytherapy (HDR) treatment planning systems usually calculate dose only from source stopping positions (stationary component), but fails to account for the administered dose when the source is moving (dynamic component or transit dose). Numerical values of this transit dose depends upon the source velocity, implant geometry, source activity and prescribed dose. In some HDR treatments using particular geometry the transit dose cannot be ignored because it increases the dose at the prescriptions points and also could increase potential late tissue complications as predicted by the linear quadratic model. International protocols recommend to verify this parameter. The aim of this paper has been to establish a procedure for the transit dose calculation for the Gammamed 12i equipment at the RT Department in the Clinical University Hospital (Zaragoza-Spain). A numeric algorithm was implemented based on a dynamic point approximation for the moving HDR source and the calculated results for the entrance-exit transit dose was compared with TLD measurements made in some discrete points. (author) [es

  11. Postoperative vaginal irradiation by a high dose-rate afterloading technique in endometrial carcinoma stage I

    International Nuclear Information System (INIS)

    Sorbe, B.; Smeds, A.C.

    1989-01-01

    A high dose-rate (cobalt-60) afterloading technique was used for postoperative vaginal irradiation in a series of 404 women with endometrial carcinoma stage I. The total recurrence rate was 3.7% with 0.7% vaginal lesions. The crude 5-year survival rate for the complete series was 91.8% compared to 13.3% for those with recurrences. Depth of myometrical infiltration (>1/3 of the uterine wall) and nuclear grade were the most important prognostic factors. Clinically significant late radiation reactions (bladder and/or rectum) were recorded in 6.9%. The absorbed dose per fraction and the size of the treatment volume were significantly related to the occurrence of both early and late radiation reactions. Vaginal shortening was closely related to the dose per fraction, length of the referce isodose and the applicator diameter. The shape of the vaginal applicator versus the isodose contours and the importance of the source train geometry and relative activity for absorbed dose inhomogeneitis within the treatment volume are discussed. Cumulative radiation effect (CRE) and linear-quadratic (LQ) calculations have been performed and related to tissue reactions within the target volume and in the risk organs. An alpha-beta quotient of 8.8 Gy for vaginal shrinkage effect and 2.0 Gy for late rectal complications are suggested on the basis of calculations using a maximum likelihood method for quantal radiation data. (orig.)

  12. Post-operative high dose rate brachytherapy in patients with low to intermediate risk endometrial cancer

    International Nuclear Information System (INIS)

    Pearcey, R.G.; Petereit, D.G.

    2000-01-01

    This paper investigates the outcome using different dose/fractionation schedules in high dose rate (HDR) post-operative vaginal vault radiotherapy in patients with low to intermediate risk endometrial cancer. The world literature was reviewed and thirteen series were analyzed representing 1800 cases. A total of 12 vaginal vault recurrences were identified representing an overall vaginal control rate of 99.3%. A wide range of dose fractionation schedules and techniques have been reported. In order to analyze a dose response relationship for tumor control and complications, the biologically effective doses to the tumor and late responding tissues were calculated using the linear quadratic model. A threshold was identified for complications, but not vaginal control. While dose fractionation schedules that delivered a biologically effective dose to the late responding tissues in excess of 100 Gy 3 (LQED = 60 Gy) predicted for late complications, dose fractionation schedules that delivered a modest dose to the vaginal surface (50 Gy 10 or LQED = 30 Gy) appeared tumoricidal with vaginal control rates of at least 98%. By using convenient, modest dose fractionation schedules, HDR vaginal vault - brachytherapy yields very high local control and extremely low morbidity rates. (author)

  13. Postoperative vaginal irradiation with high dose rate afterloading technique in endometrial carcinoma stage I

    International Nuclear Information System (INIS)

    Sorbe, B.G.; Smeds, A.C.

    1990-01-01

    A high dose rate ( 60 Co) afterloading technique was used for postoperative prophylactic vaginal irradiation in a series of 404 women with endometrial carcinoma Stage I. The total recurrence rate was 3.7% with 0.7% vaginal deposits. The crude 5-year survival rate for the complete series was 91.8% compared to 13.3% for those with recurrences. Depth of myometrial infiltration (greater than 1/3 of the uterine wall) and nuclear grade were the most important prognostic factors. Clinically significant late radiation reactions (bladder and/or rectum) were recorded in 6.9%. Dose per fraction and the size of the target volume were highly significantly related to the occurrence of both early and late radiation reactions. Vaginal shortening is closely related to the dose per fraction, length of the reference isodose, and the applicator diameter. The shape of the vaginal applicator versus the isodoses and the importance of the source train geometry and relative activity for dose gradient inhomogeneities within the target volume are discussed. Cumulative radiation effect (CRE) and linear-quadratic (LQ) calculations have been performed and related to tissue reactions within the target volume and in the risk organs. An alpha-beta quotient of 8.8 for vaginal shrinkage effect and 2.0 for late rectal complications are suggested on the basis of calculations using a maximum likelihood method for quantal radiation data

  14. Effect of high-dose preoperative methylprednisolone on recovery after total hip arthroplasty

    DEFF Research Database (Denmark)

    Lunn, T H; Andersen, Lasse Østergaard; Kristensen, B B

    2013-01-01

    (IQR) (95% CI), MP vs placebo]: 23.5 (23.3-23.7) (17.8-43.8) vs 23.5 (23.0-23.8) (20.0-46.8) h, the mean difference (95% CI) being -1.3 (-4.7 to 2.2) h, P=0.65. Overall pain for the first 24 h after surgery was significantly reduced in the MP vs the placebo group (PMP 125 mg i.v. before surgery added......BACKGROUND: /st>High-dose glucocorticoid may reduce postsurgical pain and improve recovery. We hypothesized that 125 mg methylprednisolone (MP) would reduce time to meet functional discharge criteria after total hip arthroplasty (THA). METHODS: /st>Forty-eight patients undergoing unilateral THA...... under spinal anaesthesia were consecutively included in this randomized, double-blind, placebo-controlled trial receiving preoperative i.v. MP or saline. All patients received a standardized, multimodal analgesic regime with paracetamol, celecoxib, and gabapentin. The primary outcome was time to meet...

  15. Occurrence of chronic esophageal ulcer after high dose rate intraluminal radiation therapy for esophageal cancer

    International Nuclear Information System (INIS)

    Soejima, Toshinori; Hirota, Saeko; Okamoto, Yoshiaki; Obayashi, Kayoko; Takada, Yoshiki

    1995-01-01

    Ninety-eight patients with esophageal cancer were treated by high dose rate intraluminal radiation therapy at the Department of Radiology of the Hyogo Medical Center for Adults between January 1982 and December 1993. Twenty patients with complete response after intraluminal radiation therapy, who were followed up with esophageal fiberscopy in our institute, were reviewed. The one-year cumulative rate of occurrence of esophageal ulcers was 81%, and in 69% of the cases the ulcers occurred from 4 to 8 months after completion of intraluminal radiation therapy. We graded esophageal ulcer by fiberscopic findings. Grade 0 was defined as no ulcer, grade 1 as superficial ulcer, grade 2 as deep ulcer, grade 3 as circumferencial ulcer, and severe stenosis. Factors related to grade were studied, and shorter distances from the source to the surface of the mucosa and lower surface doses of intraluminal radiation therapy appear to reduce the severity as graded on the above scale, of the esophageal ulcer. Four of the five 2-year recurrence-free patients suffered esophageal ulcers, which were cured from 15 to 22 months after intraluminal radiation therapy. However ulcers recurred in two patients, ong term care was thought to be necessary. (author)

  16. Adherence to Vaginal Dilation Following High Dose Rate Brachytherapy for Endometrial Cancer

    International Nuclear Information System (INIS)

    Friedman, Lois C.; Abdallah, Rita; Schluchter, Mark; Panneerselvam, Ashok; Kunos, Charles A.

    2011-01-01

    Purpose: We report demographic, clinical, and psychosocial factors associated with adherence to vaginal dilation and describe the sexual and marital or nonmarital dyadic functioning of women following high dose rate (HDR) brachytherapy for endometrial cancer. Methods and Materials: We retrospectively evaluated women aged 18 years or older in whom early-stage endometrial (IAgr3-IIB) cancers were treated by HDR intravaginal brachytherapy within the past 3.5 years. Women with or without a sexual partner were eligible. Patients completed questionnaires by mail or by telephone assessing demographic and clinical variables, adherence to vaginal dilation, dyadic satisfaction, sexual functioning, and health beliefs. Results: Seventy-eight of 89 (88%) eligible women with early-stage endometrial cancer treated with HDR brachytherapy completed questionnaires. Only 33% of patients were adherers, based on reporting having used a dilator more than two times per week in the first month following radiation. Nonadherers who reported a perceived change in vaginal dimension following radiation reported that their vaginas were subjectively smaller after brachytherapy (p = 0.013). Adherers reported more worry about their sex lives or lack thereof than nonadherers (p = 0.047). Patients reported considerable sexual dysfunction following completion of HDR brachytherapy. Conclusions: Adherence to recommendations for vaginal dilator use following HDR brachytherapy for endometrial cancer is poor. Interventions designed to educate women about dilator use benefit may increase adherence. Although sexual functioning was compromised, it is likely that this existed before having cancer for many women in our study.

  17. Conventional-Dose versus High-Dose Chemotherapy for Relapsed Germ Cell Tumors

    Directory of Open Access Journals (Sweden)

    Deaglan J. McHugh

    2018-01-01

    Full Text Available The majority of metastatic germ cell tumors (GCTs are cured with cisplatin-based chemotherapy, but 20–30% of patients will relapse after first-line chemotherapy and require additional salvage strategies. The two major salvage approaches in this scenario are high-dose chemotherapy (HDCT with autologous stem cell transplant (ASCT or conventional-dose chemotherapy (CDCT. Both CDCT and HDCT have curative potential in the management of relapsed/refractory GCT. However, due to a lack of conclusive randomized trials, it remains unknown whether sequential HDCT or CDCT represents the optimal initial salvage approach, with practice varying between tertiary institutions. This represents the most pressing question remaining for defining GCT treatment standards and optimizing outcomes. The authors review prognostic factors in the initial salvage setting as well as the major studies assessing the efficacy of CDCT, HDCT, or both, describing the strengths and weaknesses that formed the rationale behind the ongoing international phase III “TIGER” trial.

  18. Study of the Radiochromic Film for High Dose Measurement in Radiation Processing

    Directory of Open Access Journals (Sweden)

    CHEN Yi-zhen

    2016-02-01

    Full Text Available To establish the radiochromic film dosimeter for high dose level measurement during radiation processing, By corresponding formula and its preparation process research, batches of radiochromic film dosimeters were prepared using nylon as substrate and pararosaniline cyanide as dye. In Co-60 gamma reference radiation field, dosimetry response performance of radiochromic film was studied and results showed that the repeatability was good to 1.0%. The response curves demonstrated good linearity in the dose range of 5-210 kGy, and the signal of radiochromic film dosimeters after irradiation under the condition of low temperature storage within 2 weeks was stable. In addition, the radiochromic film dosimeters were not found to have noticeable dose rate dependence in the range of this experiment. In the linear dose range, radiochromic film dosimeter measures the absorbed dose, with extended uncertainty 4.2% (k=2 for Co-60 gamma rays. The film was suitable as dosimeters for the parameters measurement of the electron beam on the accelerator.

  19. Pulsed high-dose dexamethasone modulates Th1-/Th2-chemokine imbalance in immune thrombocytopenia.

    Science.gov (United States)

    Liu, Zongtang; Wang, Meiying; Zhou, Shufen; Ma, Ji; Shi, Yan; Peng, Jun; Hou, Ming; Guo, Chengshan

    2016-10-24

    Chemokines and chemokine receptors play important roles in autoimmune diseases; however, their role in immune thrombocytopenia (ITP) is unclear. High-dose dexamethasone (HD-DXM) may become a first-line therapy for adult patients with ITP, but the effect of HD-DXM on chemokines in ITP patients is unknown. Our aim was to investigate the mechanism of pulsed HD-DXM for management of ITP, specifically regarding the chemokine pathways. Th1-/Th2-associated chemokine and chemokine receptor profiles in ITP patients before and after pulsed HD-DXM was studied. Plasma levels of CCL5 and CXCL11 (Th1-associated) and of CCL11 (Th2-associated) were determined by ELISA. Gene expression of these three chemokines and their corresponding receptors CCR5, CXCR3, and CCR3, in peripheral blood mononuclear cells (PBMCs) was determined by quantitative RT-PCR. Thirty-three of the thirty-eight ITP patients responded effectively to HD-DXM (oral, 40 mg/day, 4 days). In ITP patients, plasma CXCL11 levels increased, while CCL11 and CCL5 decreased compared to controls (P Th1-/Th2-associated chemokines and chemokine receptors may play important roles in the pathogenesis of ITP. Importantly, regulating Th1 polarization by pulsed HD-DXM may represent a novel approach for immunoregulation in ITP.