WorldWideScience

Sample records for high-accuracy astrometric observations

  1. Accuracy of the HST Standard Astrometric Catalogs w.r.t. Gaia

    Science.gov (United States)

    Kozhurina-Platais, V.; Grogin, N.; Sabbi, E.

    2018-02-01

    The goal of astrometric calibration of the HST ACS/WFC and WFC3/UVIS imaging instruments is to provide a coordinate system free of distortion to the precision level of 0.1 pixel 4-5 mas or better. This astrometric calibration is based on two HST astrometric standard fields in the vicinity of the globular clusters, 47 Tuc and omega Cen, respectively. The derived calibration of the geometric distortion is assumed to be accurate down to 2-3 mas. Is this accuracy in agreement with the true value? Now, with the access to globally accurate positions from the first Gaia data release (DR1), we found that there are measurable offsets, rotation, scale and other deviations of distortion parameters in two HST standard astrometric catalogs. These deviations from the distortion-free and properly aligned coordinate system should be accounted and corrected for, so that the high precision HST positions are free of any systematic errors. We also found that the precision of the HST pixel coordinates is substantially better than the accuracy listed in the Gaia DR1. Therefore, in order to finalize the components of distortion in the HST standard catalogs, the next release of Gaia data is needed.

  2. Astrometric Observation of MACHO Gravitational Microlensing

    Science.gov (United States)

    Boden, A. F.; Shao, M.; Van Buren, D.

    1997-01-01

    This paper discusses the prospects for astrometric observation of MACHO gravitational microlensing events. We derive the expected astrometric observables for a simple microlensing event assuming a dark MACHO, and demonstrate that accurate astrometry can determine the lens mass, distance, and proper motion in a very general fashion.

  3. Quantum astrometric observables I: time delay in classical and quantum gravity

    NARCIS (Netherlands)

    Khavkine, I.

    2012-01-01

    A class of diffeomorphism invariant, physical observables, so-called astrometric observables, is introduced. A particularly simple example, the time delay, which expresses the difference between two initially synchronized proper time clocks in relative inertial motion, is analyzed in detail. It is

  4. An astrometric standard field in omega Cen

    Science.gov (United States)

    Wyse, Rosemary

    2003-07-01

    We propose to obtain a high-precision astrometric standard in a two-step procedure. First, we will create a ground-based astrometric standard field around omega Cen down to V=22 with a 3 mas accuracy in positions and better than 0.5 mas/yr in proper motions. This standard will be used to obtain precise absolute plate solutions for selected WFPC2 CCD frames and refine the self-calibrated mean distortion solution for the WFPC2 CCD chips. This will eliminate systematic errors inherent in the self-calibration techniques down to the rms=0.3 mas level, thus opening new opportunities to perform precision astrometry with WFPC2 alone or in combination with the other HST imaging instruments. We will also address the issue of the distortion's variation which has a paramount significance for space astrometry such as spearheaded by the HST or being under development {SIM, GAIA}. Second, all reduced WFPC2 CCD frames will be combined into the two field catalogs {astrometric flat fields} of positions in omega Cen of unprecedented precision {s.e.=0.1 mas} down to V=22 and will be available to the GO community and readily applicable to calibrating the ACS.

  5. High Astrometric Precision in the Calculation of the Coordinates of Orbiters in the GEO Ring

    Science.gov (United States)

    Lacruz, E.; Abad, C.; Downes, J. J.; Hernández-Pérez, F.; Casanova, D.; Tresaco, E.

    2018-04-01

    We present an astrometric method for the calculation of the positions of orbiters in the GEO ring with a high precision, through a rigorous astrometric treatment of observations with a 1-m class telescope, which are part of the CIDA survey of the GEO ring. We compute the distortion pattern to correct for the systematic errors introduced by the optics and electronics of the telescope, resulting in absolute mean errors of 0.16″ and 0.12″ in right ascension and declination, respectively. These correspond to ≍25 m at the mean distance of the GEO ring, and are thus good quality results.

  6. ASTROMETRIC MASSES OF 26 ASTEROIDS AND OBSERVATIONS ON ASTEROID POROSITY

    International Nuclear Information System (INIS)

    Baer, James; Chesley, Steven R.; Matson, Robert D.

    2011-01-01

    As an application of our recent observational error model, we present the astrometric masses of 26 main-belt asteroids. We also present an integrated ephemeris of 300 large asteroids, which was used in the mass determination algorithm to model significant perturbations from the rest of the main belt. After combining our mass estimates with those of other authors, we study the bulk porosities of over 50 main-belt asteroids and observe that asteroids as large as 300 km in diameter may be loose aggregates. This finding may place specific constraints on models of main-belt collisional evolution. Additionally, we observe that C-group asteroids tend to have significantly higher macroporosity than S-group asteroids.

  7. The Tycho-Gaia Astrometric Solution

    Science.gov (United States)

    Lindegren, Lennart

    2018-04-01

    Gaia DR1 is based on the first 14 months of Gaia's observations. This is not long enough to reliably disentangle the parallax effect from proper motion. For most sources, therefore, only positions and magnitudes are given. Parallaxes and proper motions were nevertheless obtained for about two million of the brighter stars through the Tycho-Gaia astrometric solution (TGAS), combining the Gaia observations with the much earlier Hipparcos and Tycho-2 positions. In this review I focus on some important characteristics and limitations of TGAS, in particular the reference frame, astrometric uncertainties, correlations, and systematic errors.

  8. Faster, Better, Cheaper: News on Seeking Gaia's Astrometric Solution with AGIS

    Science.gov (United States)

    Lammers, U.; Lindegren, L.; Bombrun, A.; O'Mullane, W.; Hobbs, D.

    2010-12-01

    Gaia is ESA’s ambitious space astrometry mission with a foreseen launch date in early 2012. Its main objective is to perform a stellar census of the 1000 Million brightest objects in our galaxy (completeness to V=20 mag) from which an astrometric catalog of micro-arcsec level accuracy will be constructed. A key element in this endeavor is the Astrometric Global Iterative Solution (AGIS) - the mathematical and numerical framework for combining the ≍80 available observations per star obtained during Gaia’s 5yr lifetime into a single global astrometric solution. At last year’s ADASS XVIII we presented (O4.1) in detail the fundamental working principles of AGIS, its development status, and selected results obtained by running the system on processing hardware at ESAC, Madrid with large-scale simulated data sets. We present here the latest developments around AGIS highlighting in particular a much improved algebraic solving method that has recently been implemented. This Conjugate Gradient scheme improves the convergence behavior in significant ways and leads to a solution of much higher scientific quality. We also report on a new collaboration aiming at processing the data from the future small Japanese astrometry mission Nano-Jasmine with AGIS.

  9. Astrometric Results of NEOs from the Characterization and Astrometric Follow-up Program at Adler Planetarium

    Science.gov (United States)

    Nault, Kristie A.; Brucker, Melissa J.; Hammergren, Mark; Gyuk, Geza; Solontoi, Mike R.

    2015-11-01

    We present astrometric results of near-Earth objects (NEOs) targeted in fourth quarter 2014 and in 2015. This is part of Adler Planetarium’s NEO characterization and astrometric follow-up program, which uses the Astrophysical Research Consortium (ARC) 3.5-m telescope at Apache Point Observatory (APO). The program utilizes a 17% share of telescope time, amounting to a total of 500 hours per year. This time is divided up into two hour observing runs approximately every other night for astrometry and frequent half-night runs approximately several times a month for spectroscopy (see poster by M. Hammergren et. al.) and light curve studies (see poster by M. J. Brucker et. al.).Observations were made using Seaver Prototype Imaging Camera (SPIcam), a visible-wavelength, direct imaging CCD camera with 2048 x 2048 pixels and a field of view of 4.78’ x 4.78’. Observations were made using 2 x 2 binning.Special emphasis has been made to focus on the smallest NEOs, particularly around 140m in diameter. Targets were selected based on absolute magnitude (prioritizing for those with H > 25 mag to select small objects) and a 3σ uncertainty less than 400” to ensure that the target is in the FOV. Targets were drawn from the Minor Planet Center (MPC) NEA Observing Planning Aid, the JPL What’s Observable tool, and the Spaceguard priority list and faint NEO list.As of August 2015, we have detected 670 NEOs for astrometric follow-up, on point with our goal of providing astrometry on a thousand NEOs per year. Astrometric calculations were done using the interactive software tool Astrometrica, which is used for data reduction focusing on the minor bodies of the solar system. The program includes automatic reference star identification from new-generation star catalogs, access to the complete MPC database of orbital elements, and automatic moving object detection and identification.This work is based on observations done using the 3.5-m telescope at Apache Point Observatory

  10. Implementation of the Global Parameters Determination in Gaia's Astrometric Solution (AGIS)

    Science.gov (United States)

    Raison, F.; Olias, A.; Hobbs, D.; Lindegren, L.

    2010-12-01

    Gaia is ESA’s space astrometry mission with a foreseen launch date in early 2012. Its main objective is to perform a stellar census of the 1000 Million brightest objects in our galaxy (completeness to V=20 mag) from which an astrometric catalog of micro-arcsec level accuracy will be constructed. A key element in this endeavor is the Astrometric Global Iterative Solution (AGIS). A core part of AGIS is to determine the accurate spacecraft attitude, geometric instrument calibration and astrometric model parameters for a well-behaved subset of all the objects (the ‘primary stars’). In addition, a small number of global parameters will be estimated, one of these being PPN γ. We present here the implementation of the algorithms dedicated to the determination of the global parameters.

  11. COMPANIONS TO NEARBY STARS WITH ASTROMETRIC ACCELERATION. II

    International Nuclear Information System (INIS)

    Tokovinin, Andrei; Hartung, Markus; Hayward, Thomas L.

    2013-01-01

    Hipparcos astrometric binaries were observed with the NICI adaptive optics system at Gemini-S, completing the work of Paper I. Among the 65 F, G, and K dwarfs within 67 pc of the Sun studied here, we resolve 18 new subarcsecond companions, remeasure 7 known astrometric pairs, and establish the physical nature of yet another 3 wider companions. The 107 astrometric binaries targeted at Gemini so far have 38 resolved companions with separations under 3''. Modeling shows that bright enough companions with separations on the order of an arcsecond can perturb the Hipparcos astrometry when they are not accounted for in the data reduction. However, the resulting bias of parallax and proper motion is generally below formal errors and such companions cannot produce fake acceleration. This work contributes to the multiplicity statistics of nearby dwarfs by bridging the gap between spectroscopic and visual binaries and by providing estimates of periods and mass ratios for many astrometric binaries.

  12. Astrometric properties of the Tautenburg Plate Scanner

    Science.gov (United States)

    Brunzendorf, Jens; Meusinger, Helmut

    The Tautenburg Plate Scanner (TPS) is an advanced plate-measuring machine run by the Thüringer Landessternwarte Tautenburg (Karl Schwarzschild Observatory), where the machine is housed. It is capable of digitising photographic plates up to 30 cm × 30 cm in size. In our poster, we reported on tests and preliminary results of its astrometric properties. The essential components of the TPS consist of an x-y table movable between an illumination system and a direct imaging system. A telecentric lens images the light transmitted through the photographic emulsion onto a CCD line of 6000 pixels of 10 µm square size each. All components are mounted on a massive air-bearing table. Scanning is performed in lanes of up to 55 mm width by moving the x-y table in a continuous drift-scan mode perpendicular to the CCD line. The analogue output from the CCD is digitised to 12 bit with a total signal/noise ratio of 1000 : 1, corresponding to a photographic density range of three. The pixel map is produced as a series of optionally overlapping lane scans. The pixel data are stored onto CD-ROM or DAT. A Tautenburg Schmidt plate 24 cm × 24 cm in size is digitised within 2.5 hours resulting in 1.3 GB of data. Subsequent high-level data processing is performed off-line on other computers. During the scanning process, the geometry of the optical components is kept fixed. The optimal focussing of the optics is performed prior to the scan. Due to the telecentric lens refocussing is not required. Therefore, the main source of astrometric errors (beside the emulsion itself) are mechanical imperfections in the drive system, which have to be divided into random and systematic ones. The r.m.s. repeatability over the whole plate as measured by repeated scans of the same plate is about 0.5 µm for each axis. The mean plate-to-plate accuracy of the object positions on two plates with the same epoch and the same plate centre has been determined to be about 1 µm. This accuracy is comparable to

  13. ASTROMETRIC REVERBERATION MAPPING

    International Nuclear Information System (INIS)

    Shen Yue

    2012-01-01

    Spatially extended emission regions of active galactic nuclei respond to continuum variations, if such emission regions are powered by energy reprocessing of the continuum. The response from different parts of the reverberating region arrives at different times lagging behind the continuum variation. The lags can be used to map the geometry and kinematics of the emission region (i.e., reverberation mapping, RM). If the extended emission region is not spherically symmetric in configuration and velocity space, reverberation may produce astrometric offsets in the emission region photocenter as a function of time delay and velocity, detectable with future μas to tens of μas astrometry. Such astrometric responses provide independent constraints on the geometric and kinematic structure of the extended emission region, complementary to traditional RM. In addition, astrometric RM is more sensitive to infer the inclination of a flattened geometry and the rotation angle of the extended emission region.

  14. A SEARCH FOR STELLAR-MASS BLACK HOLES VIA ASTROMETRIC MICROLENSING

    Energy Technology Data Exchange (ETDEWEB)

    Lu, J. R. [Astronomy Department, University of California, Berkeley, CA 94720 (United States); Sinukoff, E. [Institute for Astronomy, University of Hawai‘i at Mānoa, Honolulu, HI 96822 (United States); Ofek, E. O. [Department of Particle Physics and Astrophysics, Weizmann Institute of Science, Rehovot, 76100 (Israel); Udalski, A.; Kozlowski, S. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland)

    2016-10-10

    While dozens of stellar-mass black holes (BHs) have been discovered in binary systems, isolated BHs have eluded detection. Their presence can be inferred when they lens light from a background star. We attempt to detect the astrometric lensing signatures of three photometrically identified microlensing events, OGLE-2011-BLG-0022, OGLE-2011-BLG-0125, and OGLE-2012-BLG-0169 (OB110022, OB110125, and OB120169), located toward the Galactic Bulge. These events were selected because of their long durations, which statistically favors more massive lenses. Astrometric measurements were made over one to two years using laser-guided adaptive optics observations from the W. M. Keck Observatory. Lens model parameters were first constrained by the photometric light curves. The OB120169 light curve is well fit by a single-lens model, while both OB110022 and OB110125 light curves favor binary lens models. Using the photometric fits as prior information, no significant astrometric lensing signal was detected and all targets were consistent with linear motion. The significant lack of astrometric signal constrains the lens mass of OB110022 to 0.05–1.79 M {sub ⊙} in a 99.7% confidence interval, which disfavors a BH lens. Fits to OB110125 yielded a reduced Einstein crossing time and insufficient observations during the peak, so no mass limits were obtained. Two degenerate solutions exist for OB120169, which have a lens mass between 0.2–38.8 M {sub ⊙} and 0.4–39.8 M {sub ⊙} for a 99.7% confidence interval. Follow-up observations of OB120169 will further constrain the lens mass. Based on our experience, we use simulations to design optimal astrometric observing strategies and show that with more typical observing conditions the detection of BHs is feasible.

  15. What stellar orbit is needed to measure the spin of the Galactic centre black hole from astrometric data?

    Science.gov (United States)

    Waisberg, Idel; Dexter, Jason; Gillessen, Stefan; Pfuhl, Oliver; Eisenhauer, Frank; Plewa, Phillip M.; Bauböck, Michi; Jimenez-Rosales, Alejandra; Habibi, Maryam; Ott, Thomas; von Fellenberg, Sebastiano; Gao, Feng; Widmann, Felix; Genzel, Reinhard

    2018-05-01

    Astrometric and spectroscopic monitoring of individual stars orbiting the supermassive black hole in the Galactic Center offer a promising way to detect general relativistic effects. While low-order effects are expected to be detected following the periastron passage of S2 in Spring 2018, detecting higher order effects due to black hole spin will require the discovery of closer stars. In this paper, we set out to determine the requirements such a star would have to satisfy to allow the detection of black hole spin. We focus on the instrument GRAVITY, which saw first light in 2016 and which is expected to achieve astrometric accuracies 10-100 μas. For an observing campaign with duration T years, total observations Nobs, astrometric precision σx, and normalized black hole spin χ, we find that a_orb(1-e^2)^{3/4} ≲ 300 R_S √{T/4 {yr}} (N_obs/120)^{0.25} √{10 μ as/σ _x} √{χ /0.9} is needed. For χ = 0.9 and a potential observing campaign with σ _x = 10 μas, 30 observations yr-1 and duration 4-10 yr, we expect ˜0.1 star with K < 19 satisfying this constraint based on the current knowledge about the stellar population in the central 1 arcsec. We also propose a method through which GRAVITY could potentially measure radial velocities with precision ˜50 km s-1. If the astrometric precision can be maintained, adding radial velocity information increases the expected number of stars by roughly a factor of 2. While we focus on GRAVITY, the results can also be scaled to parameters relevant for future extremely large telescopes.

  16. HIGH-PRECISION ASTROMETRIC MILLIMETER VERY LONG BASELINE INTERFEROMETRY USING A NEW METHOD FOR MULTI-FREQUENCY CALIBRATION

    Energy Technology Data Exchange (ETDEWEB)

    Dodson, Richard; Rioja, María J. [International Centre for Radio Astronomy Research, M468, The University of Western Australia, 35 Stirling Hwy, Crawley, Western Australia 6009 (Australia); Molina, Sol N.; Gómez, José L., E-mail: richard.dodson@icrar.org [Instituto de Astrofísica de Andalucía-CSIC, Glorieta de la Astronomía s/n, E-18008 Granada (Spain)

    2017-01-10

    In this paper we describe a new approach for millimeter Very Long Baseline Interferometry (mm-VLBI) calibration that provides bona-fide astrometric alignment of the millimeter-wavelength images from a single source, for the measurement of frequency-dependent effects, such as “core-shifts” near the black hole of active galactic nucleus jets. We achieve our astrometric alignment by solving first for the ionospheric (dispersive) contributions using wide-band centimeter-wavelength observations. Second, we solve for the tropospheric (non-dispersive) contributions by using fast frequency-switching at the target millimeter-wavelengths. These solutions can be scaled and transferred from low frequency to the high frequency. To complete the calibration chain an additional step is required to remove a residual constant phase offset on each antenna. The result is an astrometric calibration and the measurement of the core-shift between 22 and 43 GHz for the jet in BL Lacertae to be −8 ± 5, 20 ± 6 μ as, in R.A. and decl., respectively. By comparison to conventional phase referencing at centimeter-wavelengths we are able to show that this core shift at millimeter-wavelengths is significantly less than what would be predicted by extrapolating the low-frequency result, which closely followed the predictions of the Blandford and Königl conical jet model. As such it would be the first demonstration for the association of the VLBI core with a recollimation shock, normally hidden at low frequencies due to the optical depth, which could be responsible for the γ -ray production in blazar jets.

  17. HIGH-PRECISION ASTROMETRIC MILLIMETER VERY LONG BASELINE INTERFEROMETRY USING A NEW METHOD FOR MULTI-FREQUENCY CALIBRATION

    International Nuclear Information System (INIS)

    Dodson, Richard; Rioja, María J.; Molina, Sol N.; Gómez, José L.

    2017-01-01

    In this paper we describe a new approach for millimeter Very Long Baseline Interferometry (mm-VLBI) calibration that provides bona-fide astrometric alignment of the millimeter-wavelength images from a single source, for the measurement of frequency-dependent effects, such as “core-shifts” near the black hole of active galactic nucleus jets. We achieve our astrometric alignment by solving first for the ionospheric (dispersive) contributions using wide-band centimeter-wavelength observations. Second, we solve for the tropospheric (non-dispersive) contributions by using fast frequency-switching at the target millimeter-wavelengths. These solutions can be scaled and transferred from low frequency to the high frequency. To complete the calibration chain an additional step is required to remove a residual constant phase offset on each antenna. The result is an astrometric calibration and the measurement of the core-shift between 22 and 43 GHz for the jet in BL Lacertae to be −8 ± 5, 20 ± 6 μ as, in R.A. and decl., respectively. By comparison to conventional phase referencing at centimeter-wavelengths we are able to show that this core shift at millimeter-wavelengths is significantly less than what would be predicted by extrapolating the low-frequency result, which closely followed the predictions of the Blandford and Königl conical jet model. As such it would be the first demonstration for the association of the VLBI core with a recollimation shock, normally hidden at low frequencies due to the optical depth, which could be responsible for the γ -ray production in blazar jets.

  18. VizieR Online Data Catalog: HD 128311 radial velocity and astrometric data (McArthur+, 2014)

    Science.gov (United States)

    McArthur, B. E.; Benedict, G. F.; Henry, G. W.; Hatzes, A.; Cochran, W. D.; Harrison, T. E.; Johns-Krull, C.; Nelan, E.

    2017-05-01

    The High Resolution Spectrograph (HRS; Tull, 1998SPIE.3355..387T) at the HET at McDonald Observatory was used to make the spectroscopic observations using the iodine absorption cell method (Butler et al. 1996PASP..108..500B). Our reduction of HET HRS data is given in Bean et al. (2007AJ....134..749B), which uses the REDUCE package (Piskunov & Valenti, 2002A&A...385.1095P). Our observations include a total of 355 high-resolution spectra which were obtained between 2005 April and 2011 January. Because typically two or more observations were made in less than 1 hr per night, we observed at 161 epochs with the HET HRS. The astrometric observations were made with the Hubble Space Telescope (HST) Fine Guidance Sensor (FGS) 1r, a two-axis interferometer, in position (POS) "fringe-tracking" mode. Twenty-nine orbits of HST astrometric observations were made between 2007 December and 2009 August. (2 data files).

  19. Estimation of position and velocity for a low dynamic vehicle in near space using nonresolved photometric and astrometric data.

    Science.gov (United States)

    Jing, Nan; Li, Chuang; Chong, Yaqin

    2017-01-20

    An estimation method for indirectly observable parameters for a typical low dynamic vehicle (LDV) is presented. The estimation method utilizes apparent magnitude, azimuth angle, and elevation angle to estimate the position and velocity of a typical LDV, such as a high altitude balloon (HAB). In order to validate the accuracy of the estimated parameters gained from an unscented Kalman filter, two sets of experiments are carried out to obtain the nonresolved photometric and astrometric data. In the experiments, a HAB launch is planned; models of the HAB dynamics and kinematics and observation models are built to use as time update and measurement update functions, respectively. When the HAB is launched, a ground-based optoelectronic detector is used to capture the object images, which are processed using aperture photometry technology to obtain the time-varying apparent magnitude of the HAB. Two sets of actual and estimated parameters are given to clearly indicate the parameter differences. Two sets of errors between the actual and estimated parameters are also given to show how the estimated position and velocity differ with respect to the observation time. The similar distribution curve results from the two scenarios, which agree within 3σ, verify that nonresolved photometric and astrometric data can be used to estimate the indirectly observable state parameters (position and velocity) for a typical LDV. This technique can be applied to small and dim space objects in the future.

  20. Verification of the astrometric performance of the Korean VLBI network, using comparative SFPR studies with the VLBA AT 14/7 mm

    Energy Technology Data Exchange (ETDEWEB)

    Rioja, María J.; Dodson, Richard; Jung, TaeHyun; Sohn, Bong Won; Byun, Do-Young; Cho, Se-Hyung; Lee, Sang-Sung; Kim, Jongsoo; Kim, Kee-Tae; Oh, Chung Sik; Han, Seog-Tae; Je, Do-Heung; Chung, Moon-Hee; Wi, Seog-Oh; Kang, Jiman; Lee, Jung-Won; Chung, Hyunsoo; Kim, Hyo Ryoung; Kim, Hyun-Goo [Korea Astronomy and Space Science Institute, Daedeokdae-ro 776, Yuseong-gu, Daejeon 305-348 (Korea, Republic of); Agudo, Iván, E-mail: maria.rioja@icrar.org [Joint Institute for VLBI in Europe, Postbus 2, NL-7990 AA Dwingeloo (Netherlands); and others

    2014-11-01

    The Korean VLBI Network (KVN) is a new millimeter VLBI dedicated array with the capability to simultaneously observe at multiple frequencies, up to 129 GHz. The innovative multi-channel receivers present significant benefits for astrometric measurements in the frequency domain. The aim of this work is to verify the astrometric performance of the KVN using a comparative study with the VLBA, a well-established instrument. For that purpose, we carried out nearly contemporaneous observations with the KVN and the VLBA, at 14/7 mm, in 2013 April. The KVN observations consisted of simultaneous dual frequency observations, while the VLBA used fast frequency switching observations. We used the Source Frequency Phase Referencing technique for the observational and analysis strategy. We find that having simultaneous observations results in superior compensation for all atmospheric terms in the observables, in addition to offering other significant benefits for astrometric analysis. We have compared the KVN astrometry measurements to those from the VLBA. We find that the structure blending effects introduce dominant systematic astrometric shifts, and these need to be taken into account. We have tested multiple analytical routes to characterize the impact of the low-resolution effects for extended sources in the astrometric measurements. The results from the analysis of the KVN and full VLBA data sets agree within 2σ of the thermal error estimate. We interpret the discrepancy as arising from the different resolutions. We find that the KVN provides astrometric results with excellent agreement, within 1σ, when compared to a VLBA configuration that has a similar resolution. Therefore, this comparative study verifies the astrometric performance of the KVN using SFPR at 14/7 mm, and validates the KVN as an astrometric instrument.

  1. Observing exoplanet populations with high-precision astrometry

    Science.gov (United States)

    Sahlmann, Johannes

    2012-06-01

    This thesis deals with the application of the astrometry technique, consisting in measuring the position of a star in the plane of the sky, for the discovery and characterisation of extra-solar planets. It is feasible only with a very high measurement precision, which motivates the use of space observatories, the development of new ground-based astronomical instrumentation and of innovative data analysis methods: The study of Sun-like stars with substellar companions using CORALIE radial velocities and HIPPARCOS astrometry leads to the determination of the frequency of close brown dwarf companions and to the discovery of a dividing line between massive planets and brown dwarf companions; An observation campaign employing optical imaging with a very large telescope demonstrates sufficient astrometric precision to detect planets around ultra-cool dwarf stars and the first results of the survey are presented; Finally, the design and initial astrometric performance of PRIMA, ! a new dual-feed near-infrared interferometric observing facility for relative astrometry is presented.

  2. Implementing the Gaia Astrometric Global Iterative Solution (AGIS) in Java

    OpenAIRE

    O'Mullane, William; Lammers, Uwe; Lindegren, Lennart; Hernandez, Jose; Hobbs, David

    2011-01-01

    This paper provides a description of the Java software framework which has been constructed to run the Astrometric Global Iterative Solution for the Gaia mission. This is the mathematical framework to provide the rigid reference frame for Gaia observations from the Gaia data itself. This process makes Gaia a self calibrated, and input catalogue independent, mission. The framework is highly distributed typically running on a cluster of machines with a database back end. All code is written in ...

  3. Inferring Binary and Trinary Stellar Populations in Photometric and Astrometric Surveys

    Science.gov (United States)

    Widmark, Axel; Leistedt, Boris; Hogg, David W.

    2018-04-01

    Multiple stellar systems are ubiquitous in the Milky Way but are often unresolved and seen as single objects in spectroscopic, photometric, and astrometric surveys. However, modeling them is essential for developing a full understanding of large surveys such as Gaia and connecting them to stellar and Galactic models. In this paper, we address this problem by jointly fitting the Gaia and Two Micron All Sky Survey photometric and astrometric data using a data-driven Bayesian hierarchical model that includes populations of binary and trinary systems. This allows us to classify observations into singles, binaries, and trinaries, in a robust and efficient manner, without resorting to external models. We are able to identify multiple systems and, in some cases, make strong predictions for the properties of their unresolved stars. We will be able to compare such predictions with Gaia Data Release 4, which will contain astrometric identification and analysis of binary systems.

  4. THE APPLICATION OF MULTIVIEW METHODS FOR HIGH-PRECISION ASTROMETRIC SPACE VLBI AT LOW FREQUENCIES

    Energy Technology Data Exchange (ETDEWEB)

    Dodson, R.; Rioja, M.; Imai, H. [International Centre for Radio Astronomy Research, M468, University of Western Australia, 35 Stirling Hwy, Crawley, Western Australia 6009 (Australia); Asaki, Y. [Institute of Space and Astronautical Science, 3-1-1 Yoshinodai, Chuou, Sagamihara, Kanagawa 252-5210 (Japan); Hong, X.-Y.; Shen, Z., E-mail: richard.dodson@icrar.org [Shanghai Astronomical Observatory, CAS, 200030 Shanghai (China)

    2013-06-15

    High-precision astrometric space very long baseline interferometry (S-VLBI) at the low end of the conventional frequency range, i.e., 20 cm, is a requirement for a number of high-priority science goals. These are headlined by obtaining trigonometric parallax distances to pulsars in pulsar-black hole pairs and OH masers anywhere in the Milky Way and the Magellanic Clouds. We propose a solution for the most difficult technical problems in S-VLBI by the MultiView approach where multiple sources, separated by several degrees on the sky, are observed simultaneously. We simulated a number of challenging S-VLBI configurations, with orbit errors up to 8 m in size and with ionospheric atmospheres consistent with poor conditions. In these simulations we performed MultiView analysis to achieve the required science goals. This approach removes the need for beam switching requiring a Control Moment Gyro, and the space and ground infrastructure required for high-quality orbit reconstruction of a space-based radio telescope. This will dramatically reduce the complexity of S-VLBI missions which implement the phase-referencing technique.

  5. THE APPLICATION OF MULTIVIEW METHODS FOR HIGH-PRECISION ASTROMETRIC SPACE VLBI AT LOW FREQUENCIES

    International Nuclear Information System (INIS)

    Dodson, R.; Rioja, M.; Imai, H.; Asaki, Y.; Hong, X.-Y.; Shen, Z.

    2013-01-01

    High-precision astrometric space very long baseline interferometry (S-VLBI) at the low end of the conventional frequency range, i.e., 20 cm, is a requirement for a number of high-priority science goals. These are headlined by obtaining trigonometric parallax distances to pulsars in pulsar-black hole pairs and OH masers anywhere in the Milky Way and the Magellanic Clouds. We propose a solution for the most difficult technical problems in S-VLBI by the MultiView approach where multiple sources, separated by several degrees on the sky, are observed simultaneously. We simulated a number of challenging S-VLBI configurations, with orbit errors up to 8 m in size and with ionospheric atmospheres consistent with poor conditions. In these simulations we performed MultiView analysis to achieve the required science goals. This approach removes the need for beam switching requiring a Control Moment Gyro, and the space and ground infrastructure required for high-quality orbit reconstruction of a space-based radio telescope. This will dramatically reduce the complexity of S-VLBI missions which implement the phase-referencing technique.

  6. ESPRI: Astrometric planet search with PRIMA at the VLTI

    Directory of Open Access Journals (Sweden)

    Ségransan D.

    2011-07-01

    Full Text Available The ESPRI consortium will conduct an astrometric survey for extrasolar planets, using the PRIMA facility at the Very Large Telescope Interferometer. Our scientific goals include determining orbital inclinations and masses for planets already known from radial-velocity surveys, searches for planets around nearby stars of all masses, and around young stars. The consortium has built the PRIMA differential delay lines, developed an astrometric operation and calibration plan, and will deliver astrometric data reduction software.

  7. The laser astrometric test of relativity mission

    International Nuclear Information System (INIS)

    Turyshev, Slava G.; Shao, Michael; Nordtvedt, Kenneth L.

    2004-01-01

    This paper discusses new fundamental physics experiment to test relativistic gravity at the accuracy better than the effects of the 2nd order in the gravitational field strength, ∝ G 2 . The Laser Astrometric Test Of Relativity (LATOR) mission uses laser interferometry between two micro-spacecraft whose lines of sight pass close by the Sun to accurately measure deflection of light in the solar gravity. The key element of the experimental design is a redundant geometry optical truss provided by a long-baseline (100 m) multi-channel stellar optical interferometer placed on the International Space Station (ISS). The interferometer is used for measuring the angles between the two spacecraft. In Euclidean geometry, determination of a triangle's three sides determines any angle therein; with gravity changing the optical lengths of sides passing close by the Sun and deflecting the light, the Euclidean relationships are overthrown. The geometric redundancy enables LATOR to measure the departure from Euclidean geometry caused by the solar gravity field to a very high accuracy. LATOR will not only improve the value of the parameterized post-Newtonian (PPN) parameter γ to unprecedented levels of accuracy of 10 -8 , it will also reach ability to measure effects of the next post-Newtonian order (c -4 ) of light deflection resulting from gravity's intrinsic non-linearity. The solar quadrupole moment parameter, J2, will be measured with high precision, as well as a variety of other relativistic effects including Lense-Thirring precession. LATOR will lead to very robust advances in the tests of fundamental physics: this mission could discover a violation or extension of general relativity, or reveal the presence of an additional long range interaction in the physical law. There are no analogs to the LATOR experiment; it is unique and is a natural culmination of solar system gravity experiments

  8. Implementing the Gaia Astrometric Global Iterative Solution (AGIS) in Java

    Science.gov (United States)

    O'Mullane, William; Lammers, Uwe; Lindegren, Lennart; Hernandez, Jose; Hobbs, David

    2011-10-01

    This paper provides a description of the Java software framework which has been constructed to run the Astrometric Global Iterative Solution for the Gaia mission. This is the mathematical framework to provide the rigid reference frame for Gaia observations from the Gaia data itself. This process makes Gaia a self calibrated, and input catalogue independent, mission. The framework is highly distributed typically running on a cluster of machines with a database back end. All code is written in the Java language. We describe the overall architecture and some of the details of the implementation.

  9. To Boldly Go Where No Man has Gone Before: Seeking Gaia's Astrometric Solution with AGIS

    Science.gov (United States)

    Lammers, U.; Lindegren, L.; O'Mullane, W.; Hobbs, D.

    2009-09-01

    Gaia is ESA's ambitious space astrometry mission with a foreseen launch date in late 2011. Its main objective is to perform a stellar census of the 1,000 million brightest objects in our galaxy (completeness to V=20 mag) from which an astrometric catalog of micro-arcsec (μas) level accuracy will be constructed. A key element in this endeavor is the Astrometric Global Iterative Solution (AGIS) - the mathematical and numerical framework for combining the ≈80 available observations per star obtained during Gaia's 5 yr lifetime into a single global astrometic solution. AGIS consists of four main algorithmic cores which improve the source astrometic parameters, satellite attitude, calibration, and global parameters in a block-iterative manner. We present and discuss this basic scheme, the algorithms themselves and the overarching system architecture. The latter is a data-driven distributed processing framework designed to achieve an overall system performance that is not I/O limited. AGIS is being developed as a pure Java system by a small number of geographically distributed European groups. We present some of the software engineering aspects of the project and show used methodologies and tools. Finally we will briefly discuss how AGIS is embedded into the overall Gaia data processing architecture.

  10. Astrometric vs. photometric microlensing

    NARCIS (Netherlands)

    Dominik, M; Brainerd, TG; Kochanek, CS

    2001-01-01

    I discuss the differences between the properties of astrometric and photometric microlensing and between the arising prospects for survey and follow-up experiments based on these two different signatures. In particular, the prospects for binary stars and extra-solar planets are considered.

  11. The astrometric lessons of Gaia-GBOT experiment

    Science.gov (United States)

    Bouquillon, S.; Mendez, R. A.; Altmann, M.

    2017-07-01

    To ensure the full capabilities of the Gaia's measurements, a programme of daily observations with Earth-based telescopes of the satellite itself - called Ground Based Optical Tracking (GBOT) - was implemented since the beginning of the Gaia mission (for more details concerning GBOT operating see Altmann et al. 2014 and concerning GBOT software facilities see Bouquillon et al. 2014). These observations are carried out mainly with two facilities: the 2.6m VLT Survey Telescope (ESO's VST) at the Cerro Paranal in Chile and the 2.0m Liverpool Telescope (LT) on the Canary Island of La Palma. The constraint of 20 mas on the tracking astrometric quality and the fact that Gaia is a faint and relatively fast moving target (its magnitude in a red passband is around 21 and its apparent speed around 0.04"/s), lead us to rigorously analyse the reachable astrometric precision for CCD observations of this kind of celestial objects. During LARIM 2016, we presented the main results of this study which uses the Cramér-Rao lower bound to characterize the precision limit for the PSF center when drifting in the CCD-frame. This work extends earlier studies dealing with one-dimensional detectors and stationary sources (Mendez et al. 2013 & 2014) firstly to the case of standard two-dimensional CCD sensors, and then, to moving sources. These new results have been submitted for a publication in A&A journal this year (Bouquillon et al. 2017).

  12. VLT/SPHERE robust astrometry of the HR8799 planets at milliarcsecond-level accuracy. Orbital architecture analysis with PyAstrOFit

    Science.gov (United States)

    Wertz, O.; Absil, O.; Gómez González, C. A.; Milli, J.; Girard, J. H.; Mawet, D.; Pueyo, L.

    2017-02-01

    Context. HR8799 is orbited by at least four giant planets, making it a prime target for the recently commissioned Spectro-Polarimetric High-contrast Exoplanet REsearch (VLT/SPHERE). As such, it was observed on five consecutive nights during the SPHERE science verification in December 2014. Aims: We aim to take full advantage of the SPHERE capabilities to derive accurate astrometric measurements based on H-band images acquired with the Infra-Red Dual-band Imaging and Spectroscopy (IRDIS) subsystem, and to explore the ultimate astrometric performance of SPHERE in this observing mode. We also aim to present a detailed analysis of the orbital parameters for the four planets. Methods: We performed thorough post-processing of the IRDIS images with the Vortex Imaging Processing (VIP) package to derive a robust astrometric measurement for the four planets. This includes the identification and careful evaluation of the different contributions to the error budget, including systematic errors. Combining our astrometric measurements with the ones previously published in the literature, we constrain the orbital parameters of the four planets using PyAstrOFit, our new open-source python package dedicated to orbital fitting using Bayesian inference with Monte-Carlo Markov Chain sampling. Results: We report the astrometric positions for epoch 2014.93 with an accuracy down to 2.0 mas, mainly limited by the astrometric calibration of IRDIS. For each planet, we derive the posterior probability density functions for the six Keplerian elements and identify sets of highly probable orbits. For planet d, there is clear evidence for nonzero eccentricity (e 0.35), without completely excluding solutions with smaller eccentricities. The three other planets are consistent with circular orbits, although their probability distributions spread beyond e = 0.2, and show a peak at e ≃ 0.1 for planet e. The four planets have consistent inclinations of approximately 30° with respect to the sky

  13. VLBI FOR GRAVITY PROBE B. IV. A NEW ASTROMETRIC ANALYSIS TECHNIQUE AND A COMPARISON WITH RESULTS FROM OTHER TECHNIQUES

    International Nuclear Information System (INIS)

    Lebach, D. E.; Ratner, M. I.; Shapiro, I. I.; Bartel, N.; Bietenholz, M. F.; Lederman, J. I.; Ransom, R. R.; Campbell, R. M.; Gordon, D.; Lestrade, J.-F.

    2012-01-01

    When very long baseline interferometry (VLBI) observations are used to determine the position or motion of a radio source relative to reference sources nearby on the sky, the astrometric information is usually obtained via (1) phase-referenced maps or (2) parametric model fits to measured fringe phases or multiband delays. In this paper, we describe a 'merged' analysis technique which combines some of the most important advantages of these other two approaches. In particular, our merged technique combines the superior model-correction capabilities of parametric model fits with the ability of phase-referenced maps to yield astrometric measurements of sources that are too weak to be used in parametric model fits. We compare the results from this merged technique with the results from phase-referenced maps and from parametric model fits in the analysis of astrometric VLBI observations of the radio-bright star IM Pegasi (HR 8703) and the radio source B2252+172 nearby on the sky. In these studies we use central-core components of radio sources 3C 454.3 and B2250+194 as our positional references. We obtain astrometric results for IM Peg with our merged technique even when the source is too weak to be used in parametric model fits, and we find that our merged technique yields astrometric results superior to the phase-referenced mapping technique. We used our merged technique to estimate the proper motion and other astrometric parameters of IM Peg in support of the NASA/Stanford Gravity Probe B mission.

  14. Photographic observations of major planets and their moons in MAO NAS of Ukraine during 1961-1990

    Science.gov (United States)

    Yizhakevych, O.; Andruk, V.; Pakuliak, L.; Lukianchuk, V.

    2017-06-01

    We present the results of digitizing and processing of archival observations to obtain the astrometric positions and stellar magnitudes of major planets and their satellites. The work has been done within the framework of the national project "Ukrainian Virtual Observatory" on the basis of photographic observations carried out in MAO NASU. The processing of digital images and the astrometric reduction of data was made in the software package created and developed in MAO for the reduction astrometric negatives. The catalogue includes data of Saturn's moons (S2-S9), obtained using 4 telescopes in 1961-1990. The stellar catalogue TYCHO2 was used as the reference. The internal positional accuracy is ˜ 0.09 - ˜ 0.25 arcsec.The same procedure is now applying for the processing of photographic observations of Neptune, Uranus, and their moons, obtained in MAO during the same period.

  15. Detailed Astrometric Analysis of Pluto

    Science.gov (United States)

    ROSSI, GUSTAVO B.; Vieira-Martins, R.; Camargo, J. I.; Assafin, M.

    2013-05-01

    Abstract (2,250 Maximum Characters): Pluto is the main representant of the transneptunian objects (TNO's), presenting some peculiarities such as an atmosphere and a satellite system with 5 known moons: Charon, discovered in 1978, Nix and Hydra, in 2006, P4 in 2011 and P5 in 2012. Until the arrival of the New Horizons spacecraft to this system (july 2015), stellar occultations are the most efficient method, from the ground, to know physical and dinamical properties of this system. In 2010, it was evident a drift in declinations (about 20 mas/year) comparing to the ephemerides. This fact motivated us to remake the reductions and analysis of a great set of our observations at OPD/LNA, in a total of 15 years. The ephemerides and occultations results was then compared with the astrometric and photometric reductions of CCD images of Pluto (around 6500 images). Two corrections were used for a refinement of the data set: diferential chromatic refraction and photocenter. The first is due to the mean color of background stars beeing redder than the color of Pluto, resulting in a slightly different path of light through the atmosphere (that may cause a difference in position of 0.1”). It became more evident because Pluto is crossing the region of the galactic plane. The photocenter correction is based on two gaussians curves overlapped, with different hights and non-coincident centers, corresponding to Pluto and Charon (since they have less than 1” of angular separation). The objective is to separate these two gaussian curves from the observed one and find the right position of Pluto. The method is strongly dependent of the hight of each of the gaussian curves, related to the respective albedos of charon and Pluto. A detailed analysis of the astrometric results, as well a comparison with occultation results was made. Since Pluto has an orbital period of 248,9 years and our interval of observation is about 15 years, we have around 12% of its observed orbit and also, our

  16. On an Allan variance approach to classify VLBI radio-sources on the basis of their astrometric stability

    Science.gov (United States)

    Gattano, C.; Lambert, S.; Bizouard, C.

    2017-12-01

    In the context of selecting sources defining the celestial reference frame, we compute astrometric time series of all VLBI radio-sources from observations in the International VLBI Service database. The time series are then analyzed with Allan variance in order to estimate the astrometric stability. From results, we establish a new classification that takes into account the whole multi-time scales information. The algorithm is flexible on the definition of ``stable source" through an adjustable threshold.

  17. Properties of comet Halley derived from thermal models and astrometric data

    International Nuclear Information System (INIS)

    Hechler, F.W.; Morley, T.A.; Mahr, P.

    1986-01-01

    The motion of a comet nucleus is influenced by outgassing forces. The orbit determination from astrometric data of comet Halley using empiric force and observation bias models and the incorporation of thermal models developed at ESOC into the orbit determination allows to draw some conclusions on the comet Halley dynamics and physics. 21 references

  18. Tracing light propagation to the intrinsic accuracy of spacetime geometry

    International Nuclear Information System (INIS)

    Crosta, Mariateresa

    2011-01-01

    Advancement in astronomical observations requires codification of light propagation and of the processes of its physical measurement at a high level of accuracy. This could unveil a new window of several subtle relativistic effects suffered by light while propagating. Indeed, light modeling and its subsequent detection should be conceived in a fully relativistic context, in order to interpret the outcome of the observing process in accordance with the geometrical environment affecting light propagation itself and the precepts of measurement. This paper deals with the complexity of such a topic by showing how the geometrical framework of RAMOD, a relativistic model initially developed for astrometric observations in the visible, constitutes an appropriate environment for back-tracing photons. Through gauging the energy content of a given gravitationally bound system, the geometrical aspects that match the required accuracy of present and future observational capabilities are evidenced. Then, by comparing different formulations of the null geodesic, their domain of validity within the given geometrical scheme is refined. Finally, by proving its ability in retrieving recent literature cases, RAMOD is promoted as a measurement-based general relativistic method for any present and future advancement in the light-tracing problem. (paper)

  19. High Precision Optical Observations of Space Debris in the Geo Ring from Venezuela

    Science.gov (United States)

    Lacruz, E.; Abad, C.; Downes, J. J.; Casanova, D.; Tresaco, E.

    2018-01-01

    We present preliminary results to demonstrate that our method for detection and location of Space Debris (SD) in the geostationary Earth orbit (GEO) ring, based on observations at the OAN of Venezuela is of high astrometric precision. A detailed explanation of the method, its validation and first results is available in (Lacruz et al. 2017).

  20. News on Seeking Gaia's Astrometric Core Solution with AGIS

    Science.gov (United States)

    Lammers, U.; Lindegren, L.

    We report on recent new developments around the Astrometric Global Iterative Solution system. This includes the availability of an efficient Conjugate Gradient solver and the Generic Astrometric Calibration scheme that had been proposed a while ago. The number of primary stars to be included in the core solution is now believed to be significantly higher than the 100 Million that served as baseline until now. Cloud computing services are being studied as a possible cost-effective alternative to running AGIS on dedicated computing hardware at ESAC during the operational phase.

  1. A NEW APPLICATION OF THE ASTROMETRIC METHOD TO BREAK SEVERE DEGENERACIES IN BINARY MICROLENSING EVENTS

    International Nuclear Information System (INIS)

    Chung, Sun-Ju; Park, Byeong-Gon; Humphrey, Andrew; Ryu, Yoon-Hyun

    2009-01-01

    When a source star is microlensed by one stellar component of widely separated binary stellar components, after finishing the lensing event, the event induced by the other binary star can be additionally detected. In this paper, we investigate whether the close/wide degeneracies in binary lensing events can be resolved by detecting the additional centroid shift of the source images induced by the secondary binary star in wide binary lensing events. From this investigation, we find that if the source star passes close to the Einstein ring of the secondary companion, the degeneracy can be easily resolved by using future astrometric follow-up observations with high astrometric precision. We determine the probability of detecting the additional centroid shift in binary lensing events with high magnification. From this, we find that the degeneracy of binary lensing events with a separation of ∼<20.0 AU can be resolved with a significant efficiency. We also estimate the waiting time for the detection of the additional centroid shift in wide binary lensing events. We find that for typical Galactic lensing events with a separation of ∼<20.0 AU, the additional centroid shift can be detected within 100 days, and thus the degeneracy of those events can be sufficiently broken within a year.

  2. High Accuracy Ground-based near-Earth-asteroid Astrometry using Synthetic Tracking

    Science.gov (United States)

    Zhai, Chengxing; Shao, Michael; Saini, Navtej; Sandhu, Jagmit; Werne, Thomas; Choi, Philip; Ely, Todd A.; Jacobs, Chirstopher S.; Lazio, Joseph; Martin-Mur, Tomas J.; Owen, William M.; Preston, Robert; Turyshev, Slava; Michell, Adam; Nazli, Kutay; Cui, Isaac; Monchama, Rachel

    2018-01-01

    Accurate astrometry is crucial for determining the orbits of near-Earth-asteroids (NEAs). Further, the future of deep space high data rate communications is likely to be optical communications, such as the Deep Space Optical Communications package that is part of the baseline payload for the planned Psyche Discovery mission to the Psyche asteroid. We have recently upgraded our instrument on the Pomona College 1 m telescope, at JPL's Table Mountain Facility, for conducting synthetic tracking by taking many short exposure images. These images can be then combined in post-processing to track both asteroid and reference stars to yield accurate astrometry. Utilizing the precision of the current and future Gaia data releases, the JPL-Pomona College effort is now demonstrating precision astrometry on NEAs, which is likely to be of considerable value for cataloging NEAs. Further, treating NEAs as proxies of future spacecraft that carry optical communication lasers, our results serve as a measure of the astrometric accuracy that could be achieved for future plane-of-sky optical navigation.

  3. High-precision astrometry towards ELTs

    NARCIS (Netherlands)

    Massari, Davide; Fiorentino, Giuliana; Tolstoy, Eline; McConnachie, Alan; Stuik, Remko; Schreiber, Laura; Andersen, David; Clénet, Yann; Davies, Richard; Gratadour, Damien; Kuijken, Konrad; Navarro, Ramon; Pott, Jörg-Uwe; Rodeghiero, Gabriele; Turri, Paolo; Verdoes Kleijn, Gijs

    2016-01-01

    With the aim of paving the road for future accurate astrometry with MICADO at the European-ELT, we performed an astrometric study using two different but complementary approaches to investigate two critical components that contribute to the total astrometric accuracy. First, we tested the predicted

  4. PACMAN: PRIMA astrometric instrument software

    Science.gov (United States)

    Abuter, Roberto; Sahlmann, Johannes; Pozna, Eszter

    2010-07-01

    The dual feed astrometric instrument software of PRIMA (PACMAN) that is currently being integrated at the VLTI will use two spatially modulated fringe sensor units and a laser metrology system to carry out differential astrometry. Its software and hardware compromises a distributed system involving many real time computers and workstations operating in a synchronized manner. Its architecture has been designed to allow the construction of efficient and flexible calibration and observation procedures. In parallel, a novel scheme of integrating M-code (MATLAB/OCTAVE) with standard VLT (Very Large Telescope) control software applications had to be devised in order to support numerically intensive operations and to have the capacity of adapting to fast varying strategies and algorithms. This paper presents the instrument software, including the current operational sequences for the laboratory calibration and sky calibration. Finally, a detailed description of the algorithms with their implementation, both under M and C code, are shown together with a comparative analysis of their performance and maintainability.

  5. Astrometrically registered simultaneous observations of the 22 GHz H{sub 2}O and 43 GHz SiO masers toward R Leonis Minoris using KVN and source/frequency phase referencing

    Energy Technology Data Exchange (ETDEWEB)

    Dodson, Richard; Rioja, María J.; Jung, Tae-Hyun; Sohn, Bong-Won; Byun, Do-Young; Cho, Se-Hyung; Lee, Sang-Sung; Kim, Jongsoo; Kim, Kee-Tae; Oh, Chung-Sik; Han, Seog-Tae; Je, Do-Heung; Chung, Moon-Hee; Wi, Seog-Oh; Kang, Jiman; Lee, Jung-Won; Chung, Hyunsoo; Kim, Hyo-Ryoung; Kim, Hyun-Goo; Lee, Chang-Hoon, E-mail: rdodson@kasi.re.kr [Korea Astronomy and Space Science Institute, Daedeokdae-ro 776, Yuseong-gu, Daejeon 305-348 (Korea, Republic of); and others

    2014-11-01

    Oxygen-rich asymptotic giant branch (AGB) stars can be intense emitters of SiO (v = 1 and 2, J = 1 → 0) and H{sub 2}O maser lines at 43 and 22 GHz, respectively. Very long baseline interferometry (VLBI) observations of the maser emission provide a unique tool to probe the innermost layers of the circumstellar envelopes in AGB stars. Nevertheless, the difficulties in achieving astrometrically aligned H{sub 2}O and v = 1 and v = 2 SiO maser maps have traditionally limited the physical constraints that can be placed on the SiO maser pumping mechanism. We present phase-referenced simultaneous spectral-line VLBI images for the SiO v = 1 and v = 2, J = 1 → 0, and H{sub 2}O maser emission around the AGB star R LMi, obtained from the Korean VLBI Network (KVN). The simultaneous multi-channel receivers of the KVN offer great possibilities for astrometry in the frequency domain. With this facility, we have produced images with bona fide absolute astrometric registration between high-frequency maser transitions of different species to provide the positions of the H{sub 2}O maser emission and the center of the SiO maser emission, hence reducing the uncertainty in the proper motions for R LMi by an order of magnitude over that from Hipparcos. This is the first successful demonstration of source frequency phase referencing for millimeter VLBI spectral-line observations and also where the ratio between the frequencies is not an integer.

  6. Astrometric surveys in the Gaia era

    Science.gov (United States)

    Zacharias, Norbert

    2018-04-01

    The Gaia first data release (DR1) already provides an almost error free optical reference frame on the milli-arcsecond (mas) level allowing significantly better calibration of ground-based astrometric data than ever before. Gaia DR1 provides positions, proper motions and trigonometric parallaxes for just over 2 million stars in the Tycho-2 catalog. For over 1.1 billion additional stars DR1 gives positions. Proper motions for these, mainly fainter stars (G >= 11.5) are currently provided by several new projects which combine earlier epoch ground-based observations with Gaia DR1 positions. These data are very helpful in the interim period but will become obsolete with the second Gaia data release (DR2) expected in April 2018. The era of traditional, ground-based, wide-field astrometry with the goal to provide accurate reference stars has come to an end. Future ground-based astrometry will fill in some gaps (very bright stars, observations needed at many or specific epochs) and mainly will go fainter than the Gaia limit, like the PanSTARRS and the upcoming LSST surveys.

  7. Astrometric detectability of systems with unseen companions: effects of the Earth orbital motion

    Science.gov (United States)

    Butkevich, Alexey G.

    2018-06-01

    The astrometric detection of an unseen companion is based on an analysis of the apparent motion of its host star around the system's barycentre. Systems with an orbital period close to 1 yr may escape detection if the orbital motion of their host stars is observationally indistinguishable from the effects of parallax. Additionally, an astrometric solution may produce a biased parallax estimation for such systems. We examine the effects of the orbital motion of the Earth on astrometric detectability in terms of a correlation between the Earth's orbital position and the position of the star relative to its system barycentre. The χ2 statistic for parallax estimation is calculated analytically, leading to expressions that relate the decrease in detectability and accompanying parallax bias to the position correlation function. The impact of the Earth's motion critically depends on the exoplanet's orbital period, diminishing rapidly as the period deviates from 1 yr. Selection effects against 1-yr-period systems is, therefore, expected. Statistical estimation shows that the corresponding loss of sensitivity results in a typical 10 per cent increase in the detection threshold. Consideration of eccentric orbits shows that the Earth's motion has no effect on detectability for e≳ 0.5. The dependence of the detectability on other parameters, such as orbital phases and inclination of the orbital plane to the ecliptic, are smooth and monotonic because they are described by simple trigonometric functions.

  8. Double-blind test program for astrometric planet detection with Gaia

    Science.gov (United States)

    Casertano, S.; Lattanzi, M. G.; Sozzetti, A.; Spagna, A.; Jancart, S.; Morbidelli, R.; Pannunzio, R.; Pourbaix, D.; Queloz, D.

    2008-05-01

    Aims: The scope of this paper is twofold. First, it describes the simulation scenarios and the results of a large-scale, double-blind test campaign carried out to estimate the potential of Gaia for detecting and measuring planetary systems. The identified capabilities are then put in context by highlighting the unique contribution that the Gaia exoplanet discoveries will be able to bring to the science of extrasolar planets in the next decade. Methods: We use detailed simulations of the Gaia observations of synthetic planetary systems and develop and utilize independent software codes in double-blind mode to analyze the data, including statistical tools for planet detection and different algorithms for single and multiple Keplerian orbit fitting that use no a priori knowledge of the true orbital parameters of the systems. Results: 1) Planets with astrometric signatures α≃ 3 times the assumed single-measurement error σ_ψ and period P≤ 5 yr can be detected reliably and consistently, with a very small number of false positives. 2) At twice the detection limit, uncertainties in orbital parameters and masses are typically 15-20%. 3) Over 70% of two-planet systems with well-separated periods in the range 0.2≤ P≤ 9 yr, astrometric signal-to-noise ratio 2≤α/σ_ψ≤ 50, and eccentricity e≤ 0.6 are correctly identified. 4) Favorable orbital configurations (both planets with P≤ 4 yr and α/σ_ψ≥ 10, redundancy over a factor of 2 in the number of observations) have orbital elements measured to better than 10% accuracy > 90% of the time, and the value of the mutual inclination angle i_rel determined with uncertainties ≤ 10°. 5) Finally, nominal uncertainties obtained from the fitting procedures are a good estimate of the actual errors in the orbit reconstruction. Extrapolating from the present-day statistical properties of the exoplanet sample, the results imply that a Gaia with σ_ψ = 8 μas, in its unbiased and complete magnitude-limited census of

  9. NEAT: an astrometric space telescope to search for habitable exoplanets in the solar neighborhood

    Science.gov (United States)

    Crouzier, A.; Malbet, F.; Kern, P.; Feautrier, P.; Preiss, O.; Martin, G.; Henault, F.; Stadler, E.; Lafrasse, S.; Behar, E.; Saintpe, M.; Dupont, J.; Potin, S.; Lagage, P.-O.; Cara, C.; Leger, A.; Leduigou, J.-M.; Shao, M.; Goullioud, R.

    2014-03-01

    radial velocities and direct imaging, it will explore in a quasi systematic way the nearby planetary systems. The resulting catalog of planetary systems will be very useful to constrain planetary formation models. The second objective is to find very close Earth analogs. These will be top priority targets for a spectroscopic mission aimed at detecting biomarquers. The current activities related to NEAT revolve around 3 themes: i) a lab demonstration: an optical bench replicates the NEAT optical configuration and metrology system in order to demonstrate the feasibility of measuring centroids with a differential accuracy of 5 µpixels (corresponding to 0.3 micro arc sec on sky) ii) a definition phase study of the NEAT mission done by CNES (the "French Space Agency") iii) an end to end simulation of the NEAT data reduction pipeline: from astrometric and RVs measurements to planets All of these activities are focused on the need to answer the next ESA call for M class missions in 2014 with an improved NEAT concept.

  10. Local tests of gravitation with Gaia observations of Solar System Objects

    Science.gov (United States)

    Hees, Aurélien; Le Poncin-Lafitte, Christophe; Hestroffer, Daniel; David, Pedro

    2018-04-01

    In this proceeding, we show how observations of Solar System Objects with Gaia can be used to test General Relativity and to constrain modified gravitational theories. The high number of Solar System objects observed and the variety of their orbital parameters associated with the impressive astrometric accuracy will allow us to perform local tests of General Relativity. In this communication, we present a preliminary sensitivity study of the Gaia observations on dynamical parameters such as the Sun quadrupolar moment and on various extensions to general relativity such as the parametrized post-Newtonian parameters, the fifth force formalism and a violation of Lorentz symmetry parametrized by the Standard-Model extension framework. We take into account the time sequences and the geometry of the observations that are particular to Gaia for its nominal mission (5 years) and for an extended mission (10 years).

  11. New precise astrometric observations of Nereid in 2012-2017

    Science.gov (United States)

    Yu, Y.; Qiao, R. C.; Yan, D.; Cheng, X.; Xi, X. J.; Tang, K.; Luo, H.

    2018-03-01

    Nereid is one of the most distinctive natural satellites that we know in the Solar system. The orbit of Nereid is highly eccentric and inclined with respect to the equator of its primary, Neptune. Studying Nereid is one of the inspiring ways to acquire better knowledge of the Solar system. Due to its faintness, the ground-based observations of Nereid have been limited and the observation precisions in the past were generally not high. A total of 150 new observed positions of Nereid in the period 2012-2017 were collected by the 0.8 m reflecting telescope at Xinglong station of National Astronomical Observatory and the 2.4 m reflecting telescope at Lijiang station of Yunnan Astronomical Observatory. Thanks to the high-quality reference catalogue Gaia DR1 and suitable processing methods for images, the precision of our new observations of Nereid is 2-3 times higher than those of the previous observations, and the dispersions of our observations are better than 70 mas.

  12. An accuracy measurement method for star trackers based on direct astronomic observation.

    Science.gov (United States)

    Sun, Ting; Xing, Fei; Wang, Xiaochu; You, Zheng; Chu, Daping

    2016-03-07

    Star tracker is one of the most promising optical attitude measurement devices and it is widely used in spacecraft for its high accuracy. However, how to realize and verify such an accuracy remains a crucial but unsolved issue until now. The authenticity of the accuracy measurement method of a star tracker will eventually determine the satellite performance. A new and robust accuracy measurement method for a star tracker based on the direct astronomical observation is proposed here. In comparison with the conventional method with simulated stars, this method utilizes real navigation stars as observation targets which makes the measurement results more authoritative and authentic. Transformations between different coordinate systems are conducted on the account of the precision movements of the Earth, and the error curves of directional vectors are obtained along the three axes. Based on error analysis and accuracy definitions, a three-axis accuracy evaluation criterion has been proposed in this paper, which could determine pointing and rolling accuracy of a star tracker directly. Experimental measurements confirm that this method is effective and convenient to implement. Such a measurement environment is close to the in-orbit conditions and it can satisfy the stringent requirement for high-accuracy star trackers.

  13. ASTROMETRIC JITTER OF THE SUN AS A STAR

    International Nuclear Information System (INIS)

    Makarov, V. V.; Parker, D.; Ulrich, R. K.

    2010-01-01

    The daily variation of the solar photocenter over some 11 yr is derived from the Mount Wilson data reprocessed by Ulrich et al. to closely match the surface distribution of solar irradiance. The standard deviations of astrometric jitter are 0.52 μAU and 0.39 μAU in the equatorial and the axial dimensions, respectively. The overall dispersion is strongly correlated with solar cycle, reaching 0.91 μAU at maximum activity in 2000. The largest short-term deviations from the running average (up to 2.6 μAU) occur when a group of large spots happen to lie on one side with respect to the center of the disk. The amplitude spectrum of the photocenter variations never exceeds 0.033 μAU for the range of periods 0.6-1.4 yr, corresponding to the orbital periods of planets in the habitable zone. Astrometric detection of Earth-like planets around stars as quiet as the Sun is not affected by star spot noise, but the prospects for more active stars may be limited to giant planets.

  14. INFLUENCE OF THE GALACTIC GRAVITATIONAL FIELD ON THE POSITIONAL ACCURACY OF EXTRAGALACTIC SOURCES

    International Nuclear Information System (INIS)

    Larchenkova, Tatiana I.; Lutovinov, Alexander A.; Lyskova, Natalya S.

    2017-01-01

    We investigate the influence of random variations of the Galactic gravitational field on the apparent celestial positions of extragalactic sources. The basic statistical characteristics of a stochastic process (first-order moments, an autocorrelation function and a power spectral density) are used to describe a light ray deflection in a gravitational field of randomly moving point masses as a function of the source coordinates. We map a 2D distribution of the standard deviation of the angular shifts in positions of distant sources (including reference sources of the International Celestial Reference Frame) with respect to their true positions. For different Galactic matter distributions the standard deviation of the offset angle can reach several tens of μ as (microarcsecond) toward the Galactic center, decreasing down to 4–6 μ as at high galactic latitudes. The conditional standard deviation (“jitter”) of 2.5 μ as is reached within 10 years at high galactic latitudes and within a few months toward the inner part of the Galaxy. The photometric microlensing events are not expected to be disturbed by astrometric random variations anywhere except the inner part of the Galaxy as the Einstein–Chvolson times are typically much shorter than the jittering timescale. While a jitter of a single reference source can be up to dozens of μ as over some reasonable observational time, using a sample of reference sources would reduce the error in relative astrometry. The obtained results can be used for estimating the physical upper limits on the time-dependent accuracy of astrometric measurements.

  15. INFLUENCE OF THE GALACTIC GRAVITATIONAL FIELD ON THE POSITIONAL ACCURACY OF EXTRAGALACTIC SOURCES

    Energy Technology Data Exchange (ETDEWEB)

    Larchenkova, Tatiana I. [ASC of P.N.Lebedev Physical Institute, Leninskiy prospect 53, Moscow 119991 (Russian Federation); Lutovinov, Alexander A.; Lyskova, Natalya S. [Space Research Institute, Russian Academy of Sciences, Profsoyuznaya 84/32, 117997 Moscow (Russian Federation)

    2017-01-20

    We investigate the influence of random variations of the Galactic gravitational field on the apparent celestial positions of extragalactic sources. The basic statistical characteristics of a stochastic process (first-order moments, an autocorrelation function and a power spectral density) are used to describe a light ray deflection in a gravitational field of randomly moving point masses as a function of the source coordinates. We map a 2D distribution of the standard deviation of the angular shifts in positions of distant sources (including reference sources of the International Celestial Reference Frame) with respect to their true positions. For different Galactic matter distributions the standard deviation of the offset angle can reach several tens of μ as (microarcsecond) toward the Galactic center, decreasing down to 4–6 μ as at high galactic latitudes. The conditional standard deviation (“jitter”) of 2.5 μ as is reached within 10 years at high galactic latitudes and within a few months toward the inner part of the Galaxy. The photometric microlensing events are not expected to be disturbed by astrometric random variations anywhere except the inner part of the Galaxy as the Einstein–Chvolson times are typically much shorter than the jittering timescale. While a jitter of a single reference source can be up to dozens of μ as over some reasonable observational time, using a sample of reference sources would reduce the error in relative astrometry. The obtained results can be used for estimating the physical upper limits on the time-dependent accuracy of astrometric measurements.

  16. A Predicted Astrometric Microlensing Event by a Nearby White Dwarf

    Science.gov (United States)

    McGill, Peter; Smith, Leigh C.; Wyn Evans, N.; Belokurov, Vasily; Smart, R. L.

    2018-04-01

    We used the Tycho-Gaia Astrometric Solution catalogue, part of Gaia Data Release 1, to search for candidate astrometric microlensing events expected to occur within the remaining lifetime of the Gaia satellite. Our search yielded one promising candidate. We predict that the nearby DQ type white dwarf LAWD 37 (WD 1142-645) will lens a background star and will reach closest approach on November 11th 2019 (± 4 days) with impact parameter 380 ± 10 mas. This will produce an apparent maximum deviation of the source position of 2.8 ± 0.1 mas. In the most propitious circumstance, Gaia will be able to determine the mass of LAWD 37 to ˜3%. This mass determination will provide an independent check on atmospheric models of white dwarfs with helium rich atmospheres, as well as tests of white dwarf mass radius relationships and evolutionary theory.

  17. Observational Model for Precision Astrometry with the Space Interferometry Mission

    National Research Council Canada - National Science Library

    Turyshev, Slava G; Milman, Mark H

    2000-01-01

    The Space Interferometry Mission (SIM) is a space-based 10-m baseline Michelson optical interferometer operating in the visible waveband that is designed to achieve astrometric accuracy in the single digits of the microarcsecond domain...

  18. Optical design for the Laser Astrometric Test of Relativity

    Science.gov (United States)

    Turyshev, Slava G.; Shao, Michael; Nordtvedt, Kenneth L., Jr.

    2004-01-01

    This paper discusses the Laser Astrometric Test of Relativity (LATOR) mission. LATOR is a Michelson-Morley-type experiment designed to test the pure tensor metric nature of gravitation the fundamental postulate of Einstein's theory of general relativity. With its focus on gravity's action on light propagation it complements other tests which rely on the gravitational dynamics of bodies.

  19. Astrometric Observation of Delta Cepheus

    Science.gov (United States)

    Warren, Naomi; Wilson, Betsie; Estrada, Chris; Crisafi, Kim; King, Jackie; Jones, Stephany; Salam, Akash; Warren, Glenn; Collins, S. Jananne; Genet, Russell

    2012-04-01

    Members of a Cuesta College astronomy research seminar used a manually-controlled 10-inch Newtonian Reflector telescope to determine the separation and position angle of the binary star Delta Cepheus. It was observed on the night of Saturday, October 29, 2011, at Star Hill in Santa Margarita, California. Their values of 40.2 arc seconds and 192.4 degrees were similar to those reported in the WDS (1910).

  20. The Caviar software package for the astrometric reduction of Cassini ISS images: description and examples

    Science.gov (United States)

    Cooper, N. J.; Lainey, V.; Meunier, L.-E.; Murray, C. D.; Zhang, Q.-F.; Baillie, K.; Evans, M. W.; Thuillot, W.; Vienne, A.

    2018-02-01

    Aims: Caviar is a software package designed for the astrometric measurement of natural satellite positions in images taken using the Imaging Science Subsystem (ISS) of the Cassini spacecraft. Aspects of the structure, functionality, and use of the software are described, and examples are provided. The integrity of the software is demonstrated by generating new measurements of the positions of selected major satellites of Saturn, 2013-2016, along with their observed minus computed (O-C) residuals relative to published ephemerides. Methods: Satellite positions were estimated by fitting a model to the imaged limbs of the target satellites. Corrections to the nominal spacecraft pointing were computed using background star positions based on the UCAC5 and Tycho2 star catalogues. UCAC5 is currently used in preference to Gaia-DR1 because of the availability of proper motion information in UCAC5. Results: The Caviar package is available for free download. A total of 256 new astrometric observations of the Saturnian moons Mimas (44), Tethys (58), Dione (55), Rhea (33), Iapetus (63), and Hyperion (3) have been made, in addition to opportunistic detections of Pandora (20), Enceladus (4), Janus (2), and Helene (5), giving an overall total of 287 new detections. Mean observed-minus-computed residuals for the main moons relative to the JPL SAT375 ephemeris were - 0.66 ± 1.30 pixels in the line direction and 0.05 ± 1.47 pixels in the sample direction. Mean residuals relative to the IMCCE NOE-6-2015-MAIN-coorb2 ephemeris were -0.34 ± 0.91 pixels in the line direction and 0.15 ± 1.65 pixels in the sample direction. The reduced astrometric data are provided in the form of satellite positions for each image. The reference star positions are included in order to allow reprocessing at some later date using improved star catalogues, such as later releases of Gaia, without the need to re-estimate the imaged star positions. The Caviar software is available for free download from: ftp

  1. Global astrometry with the space interferometry mission

    Science.gov (United States)

    Boden, A.; Unwin, S.; Shao, M.

    1997-01-01

    The prospects for global astrometric measurements with the space interferometry mission (SIM) are discussed. The SIM mission will perform four microarcsec astrometric measurements on objects as faint as 20 mag using the optical interferometry technique with a 10 m baseline. The SIM satellite will perform narrow angle astrometry and global astrometry by means of an astrometric grid. The sensitivities of the SIM global astrometric performance and the grid accuracy versus instrumental parameters and sky coverage schemes are reported on. The problems in finding suitable astrometric grid objects to support microarcsec astrometry, and related ground-based observation programs are discussed.

  2. The principle of measuring unusual change of underground mass by optical astrometric instrument

    Directory of Open Access Journals (Sweden)

    Wang Jiancheng

    2012-11-01

    In this study, we estimate the deflection angle of the plumb line on a ground site, and give a relation between the angle, abnormal mass and site distance (depth and horizontal distance. Then we derive the abnormality of underground material density using the plumb lines measured at different sites, and study the earthquake gestation, development and occurrence. Using the deflection angles of plumb lines observed at two sites, we give a method to calculate the mass and the center of gravity of underground materials. We also estimate the abnormal masses of latent seismic zones with different energy, using thermodynamic relations, and introduce a new optical astrometric instrument we had developed.

  3. Magnetic Field Studies in BL Lacertae through Faraday Rotation and a Novel Astrometric Technique

    Directory of Open Access Journals (Sweden)

    Sol N. Molina

    2017-12-01

    Full Text Available It is thought that dynamically important helical magnetic fields twisted by the differential rotation of the black hole’s accretion disk or ergosphere play an important role in the launching, acceleration, and collimation of active galactic nuclei (AGN jets. We present multi-frequency astrometric and polarimetric Very Long Baseline Array (VLBA images at 15, 22, and 43 GHz, as well as Faraday rotation analyses of the jet in BL Lacertae as part of a sample of AGN jets aimed to probe the magnetic field structure at the innermost scales to test jet formation models. The novel astrometric technique applied allows us to obtain the absolute position at mm wavelengths without any external calibrator.

  4. Accuracy of visual wave observation from merchant ships and estimated wave loads; Accuracy of visual wave observation from merchant ships and estimated wave loads

    Energy Technology Data Exchange (ETDEWEB)

    Kawabe, H. [National Defense Academy, Kanagawa (Japan); Masaoka, K. [University of Osaka Prefecture, Osaka (Japan). Faculty of Engineering

    1998-06-01

    There is a large number of studies on discussions concerning accuracy of visual observation of waves and the correction method thereon. This paper give considerations on observation accuracy placing a viewpoint on that by merchant ships. Based on ship meteorological observation tables reported to the Meteorological Agency of Japan on meteorology in North Pacific during 14 years from 1976 to1989, wave observation values taken by merchant ships and observation ships were compared statistically to investigate the accuracy of visual wave observations carried out by merchant ships. With regard to wave heights, the observation values taken by the observation ships and the merchant ships have strong correlation, where the merchant ships evaluate them somewhat higher than the observation ships. Regarding wave cycles of wind waves, the merchant ships tend to have the observation values on longer cycle side. Correlation between the observations values by the merchant ships and the observation ships is weak both in wind waves and swells. There is not much of variation in accuracy of observations during daytime and at night performed by the merchant ships. It will be necessary in the future to give considerations on a method to correct the observation values on wave cycles taken by the merchant ship, and on a correction method in which both of the wave cycles and the wave heights are corrected simultaneously to make the observation values of the merchant ship equal to those of the observation ships. Thus, the observation values reported by general merchant ships in a large number every year will have to be utilized more effectively. 11 refs., 21 figs., 2 tabs.

  5. Masses of the components of SB2 binaries observed with Gaia - IV. Accurate SB2 orbits for 14 binaries and masses of three binaries*

    Science.gov (United States)

    Kiefer, F.; Halbwachs, J.-L.; Lebreton, Y.; Soubiran, C.; Arenou, F.; Pourbaix, D.; Famaey, B.; Guillout, P.; Ibata, R.; Mazeh, T.

    2018-02-01

    The orbital motion of non-contact double-lined spectroscopic binaries (SB2s), with periods of a few tens of days to several years, holds unique, accurate information on individual stellar masses, which only long-term monitoring can unlock. The combination of radial velocity measurements from high-resolution spectrographs and astrometric measurements from high-precision interferometers allows the derivation of SB2 component masses down to the percent precision. Since 2010, we have observed a large sample of SB2s with the SOPHIE spectrograph at the Observatoire de Haute-Provence, aiming at the derivation of orbital elements with sufficient accuracy to obtain masses of components with relative errors as low as 1 per cent when the astrometric measurements of the Gaia satellite are taken into account. In this paper, we present the results from 6 yr of observations of 14 SB2 systems with periods ranging from 33 to 4185 days. Using the TODMOR algorithm, we computed radial velocities from the spectra and then derived the orbital elements of these binary systems. The minimum masses of the 28 stellar components are then obtained with an average sample accuracy of 1.0 ± 0.2 per cent. Combining the radial velocities with existing interferometric measurements, we derived the masses of the primary and secondary components of HIP 61100, HIP 95995 and HIP 101382 with relative errors for components (A,B) of, respectively, (2.0, 1.7) per cent, (3.7, 3.7) per cent and (0.2, 0.1) per cent. Using the CESAM2K stellar evolution code, we constrained the initial He abundance, age and metallicity for HIP 61100 and HIP 95995.

  6. Using Gaia as an Astrometric Tool for Deep Ground-based Surveys

    Science.gov (United States)

    Casetti-Dinescu, Dana I.; Girard, Terrence M.; Schriefer, Michael

    2018-04-01

    Gaia DR1 positions are used to astrometrically calibrate three epochs' worth of Subaru SuprimeCam images in the fields of globular cluster NGC 2419 and the Sextans dwarf spheroidal galaxy. Distortion-correction ``maps'' are constructed from a combination of offset dithers and reference to Gaia DR1. These are used to derive absolute proper motions in the field of NGC 2419. Notably, we identify the photometrically-detected Monoceros structure in the foreground of NGC 2419 as a kinematically-cold population of stars, distinct from Galactic-field stars. This project demonstrates the feasibility of combining Gaia with deep, ground-based surveys, thus extending high-quality astrometry to magnitudes beyond the limits of Gaia.

  7. Astrometric and photometric study of the open cluster NGC 2323

    Directory of Open Access Journals (Sweden)

    Amin M.Y.

    2017-01-01

    Full Text Available We present a study of the open cluster NGC 2323 using astrometric and photometric data. In our study we used two methods that are able to separate open cluster’s stars from those that belong to the stellar background. Our results of calculations by these two methods indicate that: 1 according to the membership probability, NGC 2323 should contain 497 stars, 2 the cluster center should be at 07h 02m 48.s02 and -08° 20' 17''74,3 the limiting radius of NGC 2323 is 2.31 ± 0.04 pc, the surface number density at this radius is 98.16 stars pc −2, 4 the magnitude function has a maximum at about mv = 14 mag, 5 the total mass of NGC 2323 is estimated dynamically by using astrometric data to be 890 M_, and statistically by using photometric data to be 900 M_, and 6 the distance and age of the cluster are found to be equal to 900 ± 100 pc, and 140 ± 20 Myr, respectively. Finally the dynamical evolution parameter τ of the cluster is about 436.2.

  8. Automatic measurement of images on astrometric plates

    Science.gov (United States)

    Ortiz Gil, A.; Lopez Garcia, A.; Martinez Gonzalez, J. M.; Yershov, V.

    1994-04-01

    We present some results on the process of automatic detection and measurement of objects in overlapped fields of astrometric plates. The main steps of our algorithm are the following: determination of the Scale and Tilt between charge coupled devices (CCD) and microscope coordinate systems and estimation of signal-to-noise ratio in each field;--image identification and improvement of its position and size;--image final centering;--image selection and storage. Several parameters allow the use of variable criteria for image identification, characterization and selection. Problems related with faint images and crowded fields will be approached by special techniques (morphological filters, histogram properties and fitting models).

  9. Preliminary Astrometric Results from the PS1 Demo Month and Routine Survey Operations

    Science.gov (United States)

    2010-09-01

    with the  2MASS  catalog 3 to  produce preliminary astrometric solutions.  Using these  coordinates, the NOFS astrometric pipeline correlates PS1...objects with other catalogs (USNO‐B1.0, SDSS, Tycho‐2,  2MASS , etc.) so that unique star identification numbers can  be assigned across all catalogs. This...correlated  pair, and the standard deviation for these pairings is about  0.3 arcsec.  Whereas the  2MASS  catalog error for a brighter  star is believed to be

  10. The science, technology and mission design for the Laser Astrometric test of relativity

    Science.gov (United States)

    Turyshev, Slava G.

    2006-01-01

    The Laser Astrometric Test of Relativity (LATOR) is a Michelson-Morley-type experiment designed to test the Einstein's general theory of relativity in the most intense gravitational environment available in the solar system - the close proximity to the Sun.

  11. Optical Tracking Data Validation and Orbit Estimation for Sparse Observations of Satellites by the OWL-Net.

    Science.gov (United States)

    Choi, Jin; Jo, Jung Hyun; Yim, Hong-Suh; Choi, Eun-Jung; Cho, Sungki; Park, Jang-Hyun

    2018-06-07

    An Optical Wide-field patroL-Network (OWL-Net) has been developed for maintaining Korean low Earth orbit (LEO) satellites' orbital ephemeris. The OWL-Net consists of five optical tracking stations. Brightness signals of reflected sunlight of the targets were detected by a charged coupled device (CCD). A chopper system was adopted for fast astrometric data sampling, maximum 50 Hz, within a short observation time. The astrometric accuracy of the optical observation data was validated with precise orbital ephemeris such as Consolidated Prediction File (CPF) data and precise orbit determination result with onboard Global Positioning System (GPS) data from the target satellite. In the optical observation simulation of the OWL-Net for 2017, an average observation span for a single arc of 11 LEO observation targets was about 5 min, while an average optical observation separation time was 5 h. We estimated the position and velocity with an atmospheric drag coefficient of LEO observation targets using a sequential-batch orbit estimation technique after multi-arc batch orbit estimation. Post-fit residuals for the multi-arc batch orbit estimation and sequential-batch orbit estimation were analyzed for the optical measurements and reference orbit (CPF and GPS data). The post-fit residuals with reference show few tens-of-meters errors for in-track direction for multi-arc batch and sequential-batch orbit estimation results.

  12. Optical Tracking Data Validation and Orbit Estimation for Sparse Observations of Satellites by the OWL-Net

    Directory of Open Access Journals (Sweden)

    Jin Choi

    2018-06-01

    Full Text Available An Optical Wide-field patroL-Network (OWL-Net has been developed for maintaining Korean low Earth orbit (LEO satellites’ orbital ephemeris. The OWL-Net consists of five optical tracking stations. Brightness signals of reflected sunlight of the targets were detected by a charged coupled device (CCD. A chopper system was adopted for fast astrometric data sampling, maximum 50 Hz, within a short observation time. The astrometric accuracy of the optical observation data was validated with precise orbital ephemeris such as Consolidated Prediction File (CPF data and precise orbit determination result with onboard Global Positioning System (GPS data from the target satellite. In the optical observation simulation of the OWL-Net for 2017, an average observation span for a single arc of 11 LEO observation targets was about 5 min, while an average optical observation separation time was 5 h. We estimated the position and velocity with an atmospheric drag coefficient of LEO observation targets using a sequential-batch orbit estimation technique after multi-arc batch orbit estimation. Post-fit residuals for the multi-arc batch orbit estimation and sequential-batch orbit estimation were analyzed for the optical measurements and reference orbit (CPF and GPS data. The post-fit residuals with reference show few tens-of-meters errors for in-track direction for multi-arc batch and sequential-batch orbit estimation results.

  13. Astrometric analysis of the unresolved binary MU Cassiopeiae from photographs taken with the Sproul 61 centimeter refractor

    International Nuclear Information System (INIS)

    Lippincott, S.L.

    1981-01-01

    Mu Cassiopeiae, a high-velocity Population II subdwarf, is an astrometric binary which has been on the Sproul Observatory astrometric program since 1937. The data yield P = 21.43 yr, with a photocentric semiaxis major, α = 0''.186 +- 0''.001 (p.e) and a relative parallax, π = +0''.130 +- 0''.001. Rigorous masses for the components from the Sproul results will follow in the future only in conjunction with reliable values for Δm and separation derived from other techniques. The best tentative values of Δm and separation so far found suggest M/sub A/ = 0.7 M/sub sun/, and M/sub B/roughly-equal0.2Msun with Δmapprox.4.5, which indicate higher. He content for μ Cas A than for the Sun. The masses are of particular interest because they hold a clue to the chemical composition of the system which is likely to be similar to that in the interstellar medium during the early stages of our Galaxy at the time μ Cas is thought to have originated

  14. On the accuracy of mass measurement for microlensing black holes as seen by Gaia and OGLE

    Science.gov (United States)

    Rybicki, Krzysztof A.; Wyrzykowski, Łukasz; Klencki, Jakub; de Bruijne, Jos; Belczyński, Krzysztof; Chruślińska, Martyna

    2018-05-01

    We investigate the impact of combining Gaia astrometry from space with precise, high cadence OGLE photometry from the ground. For the archival event OGLE3-ULENS-PAR-02, which is likely a black hole, we simulate a realistic astrometric time series of Gaia measurements and combine it with the real photometric data collected by the OGLE project. We predict that at the end of the nominal 5 yr of the Gaia mission, for the events brighter than G ≈ 15.5 mag at the baseline, caused by objects heavier than 10 M⊙, it will be possible to unambiguously derive masses of the lenses, with accuracy between a few and 15 per cent. We find that fainter events (G < 17.5) can still have their lens masses determined, provided that they are heavier than 30 M⊙. We estimate that the rate of astrometric microlensing events caused by the stellar-origin black holes is ≈ 4 × 10- 7 yr- 1, which implies, that after 5 yr of Gaia operation and ≈5 × 106 bright sources in Gaia, it will be possible to identify few such events in the Gaia final catalogues.

  15. Accuracy of clinical observations of push-off during gait after stroke.

    Science.gov (United States)

    McGinley, Jennifer L; Morris, Meg E; Greenwood, Ken M; Goldie, Patricia A; Olney, Sandra J

    2006-06-01

    To determine the accuracy (criterion-related validity) of real-time clinical observations of push-off in gait after stroke. Criterion-related validity study of gait observations. Rehabilitation hospital in Australia. Eleven participants with stroke and 8 treating physical therapists. Not applicable. Pearson product-moment correlation between physical therapists' observations of push-off during gait and criterion measures of peak ankle power generation from a 3-dimensional motion analysis system. A high correlation was obtained between the observational ratings and the measurements of peak ankle power generation (Pearson r =.98). The standard error of estimation of ankle power generation was .32W/kg. Physical therapists can make accurate real-time clinical observations of push-off during gait following stroke.

  16. Factors Determining the Inter-observer Variability and Diagnostic Accuracy of High-resolution Manometry for Esophageal Motility Disorders.

    Science.gov (United States)

    Kim, Ji Hyun; Kim, Sung Eun; Cho, Yu Kyung; Lim, Chul-Hyun; Park, Moo In; Hwang, Jin Won; Jang, Jae-Sik; Oh, Minkyung

    2018-01-30

    Although high-resolution manometry (HRM) has the advantage of visual intuitiveness, its diagnostic validity remains under debate. The aim of this study was to evaluate the diagnostic accuracy of HRM for esophageal motility disorders. Six staff members and 8 trainees were recruited for the study. In total, 40 patients enrolled in manometry studies at 3 institutes were selected. Captured images of 10 representative swallows and a single swallow in analyzing mode in both high-resolution pressure topography (HRPT) and conventional line tracing formats were provided with calculated metrics. Assessments of esophageal motility disorders showed fair agreement for HRPT and moderate agreement for conventional line tracing (κ = 0.40 and 0.58, respectively). With the HRPT format, the k value was higher in category A (esophagogastric junction [EGJ] relaxation abnormality) than in categories B (major body peristalsis abnormalities with intact EGJ relaxation) and C (minor body peristalsis abnormalities or normal body peristalsis with intact EGJ relaxation). The overall exact diagnostic accuracy for the HRPT format was 58.8% and rater's position was an independent factor for exact diagnostic accuracy. The diagnostic accuracy for major disorders was 63.4% with the HRPT format. The frequency of major discrepancies was higher for category B disorders than for category A disorders (38.4% vs 15.4%; P < 0.001). The interpreter's experience significantly affected the exact diagnostic accuracy of HRM for esophageal motility disorders. The diagnostic accuracy for major disorders was higher for achalasia than distal esophageal spasm and jackhammer esophagus.

  17. Tycho- Gaia Astrometric Solution Parallaxes and Proper Motions for Five Galactic Globular Clusters

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, Laura L.; Van der Marel, Roeland P., E-mail: lwatkins@stsci.edu [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore MD 21218 (United States)

    2017-04-20

    We present a pilot study of Galactic globular cluster (GC) proper motion (PM) determinations using Gaia data. We search for GC stars in the Tycho- Gaia Astrometric Solution (TGAS) catalog from Gaia Data Release 1 (DR1), and identify five members of NGC 104 (47 Tucanae), one member of NGC 5272 (M3), five members of NGC 6121 (M4), seven members of NGC 6397, and two members of NGC 6656 (M22). By taking a weighted average of member stars, fully accounting for the correlations between parameters, we estimate the parallax (and, hence, distance) and PM of the GCs. This provides a homogeneous PM study of multiple GCs based on an astrometric catalog with small and well-controlled systematic errors and yields random PM errors similar to existing measurements. Detailed comparison to the available Hubble Space Telescope ( HST ) measurements generally shows excellent agreement, validating the astrometric quality of both TGAS and HST . By contrast, comparison to ground-based measurements shows that some of those must have systematic errors exceeding the random errors. Our parallax estimates have uncertainties an order of magnitude larger than previous studies, but nevertheless imply distances consistent with previous estimates. By combining our PM measurements with literature positions, distances, and radial velocities, we measure Galactocentric space motions for the clusters and find that these also agree well with previous analyses. Our analysis provides a framework for determining more accurate distances and PMs of Galactic GCs using future Gaia data releases. This will provide crucial constraints on the near end of the cosmic distance ladder and provide accurate GC orbital histories.

  18. Improving the Astrometric Calibration of ACS/WFC for the Most Useful Filters

    Science.gov (United States)

    Anderson, Jay

    2004-07-01

    The distortion correction for the WFC, with which most ACS astrometry is done, is filter-dependent, and is not sufficiently accurate for the most useful filters to the community, F606W and F814W. We propose to derive improved corrections using 1 orbit for each filter. A by-product will be an astrometric standard field at the center of Omega Centauri.

  19. Using of UKRVO Data and Software for New Reductions of Photographic Observations of Selected Minor Planets

    Science.gov (United States)

    Protsyuk, Yu.; Maigurova, N.; Protsyuk, S.; Golovnia, V.

    The new reductions of available photographic plates of UkrVO digital archive containing images of selected minor planets were conducted. Data processing of these plates were carried out to check the possibility of obtaining the new positions with high accuracy in the system of Tycho2/UCAC4 reference catalogues. Archives of the Research Institute "Nikolaev Astronomical Observatory" (NAO) and Main Astronomical Observatory of National Academy of Science (MAO) were used. We have chosen near 60 plates from these archives. Observational epochs of the plates were in the range from 1974 to 1991. Usually, there were 3 exposures in each plate and each plate was scanned 6 times with 1600 dpi resolution. The full identification was conducted and coordinates of all objects were obtained with usage of different options of astrometric reductions. The inner accuracy of obtained positions is within of 0.03"-0.40". The comparison of the new topocentric positions of minor planets with Horizons ephemeris was made for calculation (O - C) residuals and their RMS. The matching with MPC data is present.

  20. Accuracy and reliability of observational gait analysis data: judgments of push-off in gait after stroke.

    Science.gov (United States)

    McGinley, Jennifer L; Goldie, Patricia A; Greenwood, Kenneth M; Olney, Sandra J

    2003-02-01

    Physical therapists routinely observe gait in clinical practice. The purpose of this study was to determine the accuracy and reliability of observational assessments of push-off in gait after stroke. Eighteen physical therapists and 11 subjects with hemiplegia following a stroke participated in the study. Measurements of ankle power generation were obtained from subjects following stroke using a gait analysis system. Concurrent videotaped gait performances were observed by the physical therapists on 2 occasions. Ankle power generation at push-off was scored as either normal or abnormal using two 11-point rating scales. These observational ratings were correlated with the measurements of peak ankle power generation. A high correlation was obtained between the observational ratings and the measurements of ankle power generation (mean Pearson r=.84). Interobserver reliability was moderately high (mean intraclass correlation coefficient [ICC (2,1)]=.76). Intraobserver reliability also was high, with a mean ICC (2,1) of.89 obtained. Physical therapists were able to make accurate and reliable judgments of push-off in videotaped gait of subjects following stroke using observational assessment. Further research is indicated to explore the accuracy and reliability of data obtained with observational gait analysis as it occurs in clinical practice.

  1. On the accuracy of Hipparcos using binary stars as a calibration tool

    Energy Technology Data Exchange (ETDEWEB)

    Docobo, J. A.; Andrade, M., E-mail: joseangel.docobo@usc.es, E-mail: manuel.andrade@usc.es [R. M. Aller Astronomical Observatory, University of Santiago de Compostela (USC), Santiago de Compostela E-15782, Galiza, P.O. Box 197 (Spain)

    2015-02-01

    Stellar binary systems, specifically those that present the most accurate available orbital elements, are a reliable tool to test the accuracy of astrometric observations. We selected all 35 binaries with these characteristics. Our objective is to provide standard uncertainties for the positions and parallaxes measured by Hipparcos relative to this trustworthy set, as well as to check supposed correlations between several parameters (measurement residuals, positions, magnitudes, and parallaxes). In addition, using the high-confidence subset of visual–spectroscopic binaries, we implemented a validation test of the Hipparcos trigonometric parallaxes of binary systems that allowed the evaluation of their reliability. Standard and non-standard statistical analysis techniques were applied in order to achieve well-founded conclusions. In particular, errors-in-variables models such as the total least-squares method were used to validate Hipparcos parallaxes by comparison with those obtained directly from the orbital elements. Previously, we executed Thompson's τ technique in order to detect suspected outliers in the data. Furthermore, several statistical hypothesis tests were carried out to verify if our results were statistically significant. A statistically significant trend indicating larger Hipparcos angular separations with respect to the reference values in 5.2 ± 1.4 mas was found at the 10{sup −8} significance level. Uncertainties in the polar coordinates θ and ρ of 1.°8 and 6.3 mas, respectively, were estimated for the Hipparcos observations of binary systems. We also verified that the parallaxes of binary systems measured in this mission are absolutely compatible with the set of orbital parallaxes obtained from the most accurate orbits at least at the 95% confidence level. This methodology allows us to better estimate the accuracy of Hipparcos observations of binary systems. Indeed, further application to the data collected by Gaia should yield a

  2. Accuracy of hiatal hernia detection with esophageal high-resolution manometry

    NARCIS (Netherlands)

    Weijenborg, P. W.; van Hoeij, F. B.; Smout, A. J. P. M.; Bredenoord, A. J.

    2015-01-01

    The diagnosis of a sliding hiatal hernia is classically made with endoscopy or barium esophagogram. Spatial separation of the lower esophageal sphincter (LES) and diaphragm, the hallmark of hiatal hernia, can also be observed on high-resolution manometry (HRM), but the diagnostic accuracy of this

  3. Gravitational lensing statistics with extragalactic surveys - II. Analysis of the Jodrell Bank-VLA Astrometric Survey

    NARCIS (Netherlands)

    Helbig, P; Marlow, D; Quast, R; Wilkinson, PN; Browne, IWA; Koopmans, LVE

    We present constraints on the cosmological constant lambda(0) from gravitational lensing statistics of the Jodrell Bank-VLA Astrometric Survey (JVAS). Although this is the largest gravitational lens survey which has been analysed, cosmological constraints are only comparable to those from optical

  4. Gravitational lensing statistics with extragalactic surveys; 2, Analysis of the Jodrell Bank-VLA Astrometric Survey

    NARCIS (Netherlands)

    Helbig, P.; Marlow, D. R.; Quast, R.; Wilkinson, P. N.; Browne, I. W. A.; Koopmans, L. V. E.

    1999-01-01

    Published in: Astron. Astrophys. Suppl. Ser. 136 (1999) no. 2, pp.297-305 citations recorded in [Science Citation Index] Abstract: We present constraints on the cosmological constant $lambda_{0}$ from gravitational lensing statistics of the Jodrell Bank-VLA Astrometric Survey (JVAS). Although this

  5. An astrometric search for a stellar companion to the sun

    International Nuclear Information System (INIS)

    Perlmutter, S.

    1986-01-01

    A companion star within 0.8 pc of the Sun has been postulated to explain a possible 26 Myr periodicity in mass extinctions of species on the Earth. Such a star would already be catalogued in the Yale Bright Star catalogue unless it is fainter than m/sub nu/ = 6.5; this limits the possible stellar types for an unseen companion to red dwarfs, brown dwarfs, or compact objects. Red dwarfs account for about 75% of these possible stars. We describe here the design and development of an astrometric search for a nearby red dwarf companion with a six-month peak-to-peak parallax of ≥2.5 arcseconds. We are measuring the parallax of 2770 candidate faint red stars selected from the Dearborn Observatory catalogue. An automated 30-inch telescope and CCD camera system collect digitized images of the candidate stars, along with a 13' x 16' surrounding field of background stars. Second-epoch images, taken a few months later, are registered to the first epoch images using the background stars as fiducials. An apparent motion, m/sub a/, of the candidate stars is found to a precision of σ/sub m//sub a/ ≅ 0.08 pixel ≅ 0.2 arcseconds for fields with N/sub fiducial/ ≥ 10 fiducial stars visible above the background noise. This precision is sufficient to detect the parallactic motion of a star at 0.8 pc with a two month interval between the observation epochs. Images with fewer fiducial stars above background noise are observed with a longer interval between epochs. If a star is found with high parallactic motion, we will confirm its distance with further parallax measurements, photometry, and spectral studies, and will measure radial velocity and proper motion to establish its orbit. We have demonstrated the search procedure with observations of 41 stars, and have shown that none of these is a nearby star. 37 refs., 16 figs., 3 tabs

  6. The Gaia Catalogue Second Data Release and Its Implications to Optical Observations of Man-Made Earth Orbiting Objects

    Science.gov (United States)

    Frith, James M.; Buckalew, Brent A.; Cowardin, Heather M.; Lederer, Susan M.

    2018-01-01

    The Gaia catalogue second data release and its implications to optical observations of man-made Earth orbiting objects. Abstract and not the Final Paper is attached. The Gaia spacecraft was launched in December 2013 by the European Space Agency to produce a three-dimensional, dynamic map of objects within the Milky Way. Gaia's first year of data was released in September 2016. Common sources from the first data release have been combined with the Tycho-2 catalogue to provide a 5 parameter astrometric solution for approximately 2 million stars. The second Gaia data release is scheduled to come out in April 2018 and is expected to provide astrometry and photometry for more than 1 billion stars, a subset of which with a the full 6 parameter astrometric solution (adding radial velocity) and positional accuracy better than 0.002 arcsec (2 mas). In addition to precise astrometry, a unique opportunity exists with the Gaia catalogue in its production of accurate, broadband photometry using the Gaia G filter. In the past, clear filters have been used by various groups to maximize likelihood of detection of dim man-made objects but these data were very difficult to calibrate. With the second release of the Gaia catalogue, a ground based system utilizing the G band filter will have access to 1.5 billion all-sky calibration sources down to an accuracy of 0.02 magnitudes or better. In this talk, we will discuss the advantages and practicalities of implementing the Gaia filters and catalogue into data pipelines designed for optical observations of man-made objects.

  7. A high accuracy land use/cover retrieval system

    Directory of Open Access Journals (Sweden)

    Alaa Hefnawy

    2012-03-01

    Full Text Available The effects of spatial resolution on the accuracy of mapping land use/cover types have received increasing attention as a large number of multi-scale earth observation data become available. Although many methods of semi automated image classification of remotely sensed data have been established for improving the accuracy of land use/cover classification during the past 40 years, most of them were employed in single-resolution image classification, which led to unsatisfactory results. In this paper, we propose a multi-resolution fast adaptive content-based retrieval system of satellite images. Through our proposed system, we apply a Super Resolution technique for the Landsat-TM images to have a high resolution dataset. The human–computer interactive system is based on modified radial basis function for retrieval of satellite database images. We apply the backpropagation supervised artificial neural network classifier for both the multi and single resolution datasets. The results show significant improved land use/cover classification accuracy for the multi-resolution approach compared with those from single-resolution approach.

  8. Micro-Arcsec mission: implications of the monitoring, diagnostic and calibration of the instrument response in the data reduction chain. .

    Science.gov (United States)

    Busonero, D.; Gai, M.

    The goals of 21st century high angular precision experiments rely on the limiting performance associated to the selected instrumental configuration and observational strategy. Both global and narrow angle micro-arcsec space astrometry require that the instrument contributions to the overall error budget has to be less than the desired micro-arcsec level precision. Appropriate modelling of the astrometric response is required for optimal definition of the data reduction and calibration algorithms, in order to ensure high sensitivity to the astrophysical source parameters and in general high accuracy. We will refer to the framework of the SIM-Lite and the Gaia mission, the most challenging space missions of the next decade in the narrow angle and global astrometry field, respectively. We will focus our dissertation on the Gaia data reduction issues and instrument calibration implications. We describe selected topics in the framework of the Astrometric Instrument Modelling for the Gaia mission, evidencing their role in the data reduction chain and we give a brief overview of the Astrometric Instrument Model Data Analysis Software System, a Java-based pipeline under development by our team.

  9. High accuracy satellite drag model (HASDM)

    Science.gov (United States)

    Storz, Mark F.; Bowman, Bruce R.; Branson, Major James I.; Casali, Stephen J.; Tobiska, W. Kent

    The dominant error source in force models used to predict low-perigee satellite trajectories is atmospheric drag. Errors in operational thermospheric density models cause significant errors in predicted satellite positions, since these models do not account for dynamic changes in atmospheric drag for orbit predictions. The Air Force Space Battlelab's High Accuracy Satellite Drag Model (HASDM) estimates and predicts (out three days) a dynamically varying global density field. HASDM includes the Dynamic Calibration Atmosphere (DCA) algorithm that solves for the phases and amplitudes of the diurnal and semidiurnal variations of thermospheric density near real-time from the observed drag effects on a set of Low Earth Orbit (LEO) calibration satellites. The density correction is expressed as a function of latitude, local solar time and altitude. In HASDM, a time series prediction filter relates the extreme ultraviolet (EUV) energy index E10.7 and the geomagnetic storm index ap, to the DCA density correction parameters. The E10.7 index is generated by the SOLAR2000 model, the first full spectrum model of solar irradiance. The estimated and predicted density fields will be used operationally to significantly improve the accuracy of predicted trajectories for all low-perigee satellites.

  10. High-Accuracy Spherical Near-Field Measurements for Satellite Antenna Testing

    DEFF Research Database (Denmark)

    Breinbjerg, Olav

    2017-01-01

    The spherical near-field antenna measurement technique is unique in combining several distinct advantages and it generally constitutes the most accurate technique for experimental characterization of radiation from antennas. From the outset in 1970, spherical near-field antenna measurements have...... matured into a well-established technique that is widely used for testing antennas for many wireless applications. In particular, for high-accuracy applications, such as remote sensing satellite missions in ESA's Earth Observation Programme with uncertainty requirements at the level of 0.05dB - 0.10d......B, the spherical near-field antenna measurement technique is generally superior. This paper addresses the means to achieving high measurement accuracy; these include the measurement technique per se, its implementation in terms of proper measurement procedures, the use of uncertainty estimates, as well as facility...

  11. A proposal for limited criminal liability in high-accuracy endoscopic sinus surgery.

    Science.gov (United States)

    Voultsos, P; Casini, M; Ricci, G; Tambone, V; Midolo, E; Spagnolo, A G

    2017-02-01

    The aim of the present study is to propose legal reform limiting surgeons' criminal liability in high-accuracy and high-risk surgery such as endoscopic sinus surgery (ESS). The study includes a review of the medical literature, focusing on identifying and examining reasons why ESS carries a very high risk of serious complications related to inaccurate surgical manoeuvers and reviewing British and Italian legal theory and case-law on medical negligence, especially with regard to Italian Law 189/2012 (so called "Balduzzi" Law). It was found that serious complications due to inaccurate surgical manoeuvers may occur in ESS regardless of the skill, experience and prudence/diligence of the surgeon. Subjectivity should be essential to medical negligence, especially regarding high-accuracy surgery. Italian Law 189/2012 represents a good basis for the limitation of criminal liability resulting from inaccurate manoeuvres in high-accuracy surgery such as ESS. It is concluded that ESS surgeons should be relieved of criminal liability in cases of simple/ordinary negligence where guidelines have been observed. © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale, Rome, Italy.

  12. Climate Change Observation Accuracy: Requirements and Economic Value

    Science.gov (United States)

    Wielicki, Bruce; Cooke, Roger; Golub, Alexander; Baize, Rosemary; Mlynczak, Martin; Lukashin, Constantin; Thome, Kurt; Shea, Yolanda; Kopp, Greg; Pilewskie, Peter; hide

    2016-01-01

    This presentation will summarize a new quantitative approach to determining the required accuracy for climate change observations. Using this metric, most current global satellite observations struggle to meet this accuracy level. CLARREO (Climate Absolute Radiance and Refractivity Observatory) is a new satellite mission designed to resolve this challenge is by achieving advances of a factor of 10 for reflected solar spectra and a factor of 3 to 5 for thermal infrared spectra. The CLARREO spectrometers can serve as SI traceable benchmarks for the Global Satellite Intercalibration System (GSICS) and greatly improve the utility of a wide range of LEO and GEO infrared and reflected solar satellite sensors for climate change observations (e.g. CERES, MODIS, VIIIRS, CrIS, IASI, Landsat, etc). A CLARREO Pathfinder mission for flight on the International Space Station is included in the U.S. Presidentâ€"TM"s fiscal year 2016 budget, with launch in 2019 or 2020. Providing more accurate decadal change trends can in turn lead to more rapid narrowing of key climate science uncertainties such as cloud feedback and climate sensitivity. A new study has been carried out to quantify the economic benefits of such an advance and concludes that the economic value is $9 Trillion U.S. dollars. The new value includes the cost of carbon emissions reductions.

  13. Three-dimensional display improves observer speed and accuracy

    International Nuclear Information System (INIS)

    Nelson, J.A.; Rowberg, A.H.; Kuyper, S.; Choi, H.S.

    1989-01-01

    In an effort to evaluate the potential cost-effectiveness of three-dimensional (3D) display equipment, we compared the speed and accuracy of experienced radiologists identifying in sliced uppercase letters from CT scans with 2D and pseudo-3D display. CT scans of six capital letters were obtained and printed as a 2D display or as a synthesized pseudo-3D display (Pixar). Six observes performed a timed identification task. Radiologists read the 3D display an average of 16 times faster than the 2D, and the average error rate of 2/6 (± 0.6/6) for 2D interpretations was totally eliminated. This degree of improvement in speed and accuracy suggests that the expense of 3D display may be cost-effective in a defined clinical setting

  14. Nano-JASMINE: use of AGIS for the next astrometric satellite

    Science.gov (United States)

    Yamada, Y.; Gouda, N.; Lammers, U.

    The core data reduction for the Nano-JASMINE mission is planned to be done with Gaia's Astrometric Global Iterative Solution (AGIS). The collaboration started at 2007 prompted by Uwe Lammers' proposal. In addition to similar design and operating principles of the two missions, this is possible thanks to the encapsulation of all Gaia-specific aspects of AGIS in a Parameter Database. Nano-JASMINE will be the test bench for Gaia AGIS software. We present this idea in detail and the necessary practical steps to make AGIS work with Nano-JASMINE data. We also show the key mission parameters, goals, and status of the data reduction for the Nano-JASMINE.

  15. Application of time transfer functions to Gaia's global astrometry. Validation on DPAC simulated Gaia-like observations

    Science.gov (United States)

    Bertone, Stefano; Vecchiato, Alberto; Bucciarelli, Beatrice; Crosta, Mariateresa; Lattanzi, Mario G.; Bianchi, Luca; Angonin, Marie-Christine; Le Poncin-Lafitte, Christophe

    2017-12-01

    Context. A key objective of the ESA Gaia satellite is the realization of a quasi-inertial reference frame at visual wavelengths by means of global astrometric techniques. This requires accurate mathematical and numerical modeling of relativistic light propagation, as well as double-blind-like procedures for the internal validation of the results, before they are released to the scientific community at large. Aims: We aim to specialize the time transfer functions (TTF) formalism to the case of the Gaia observer and prove its applicability to the task of global sphere reconstruction (GSR), in anticipation of its inclusion in the GSR system, already featuring the Relativistic Astrometric MODel (RAMOD) suite, as an additional semi-external validation of the forthcoming Gaia baseline astrometric solutions. Methods: We extended the current GSR framework and software infrastructure (GSR2) to include TTF relativistic observation equations compatible with Gaia's operations. We used simulated data generated by the Gaia Data Processing and Analysis Consortium (DPAC) to obtain different least-squares estimations of the full (five-parameter) stellar spheres and gauge results. These were compared to analogous solutions obtained with the current RAMOD model in GSR2 (RAMOD@GSR2) and to the catalog generated with the Gaia RElativistic Model (GREM), the model baselined for Gaia and used to generate the DPAC synthetic data. Results: Linearized least-squares TTF solutions are based on spheres of about 132 000 primary stars uniformly distributed on the sky and simulated observations spanning the entire 5 yr range of Gaia's nominal operational lifetime. The statistical properties of the results compare well with those of GREM. Finally, comparisons to RAMOD@GSR2 solutions confirmed the known lower accuracy of that model and allowed us to establish firm limits on the quality of the linearization point outside of which an iteration for non-linearity is required for its proper convergence

  16. High accuracy FIONA-AFM hybrid imaging

    International Nuclear Information System (INIS)

    Fronczek, D.N.; Quammen, C.; Wang, H.; Kisker, C.; Superfine, R.; Taylor, R.; Erie, D.A.; Tessmer, I.

    2011-01-01

    Multi-protein complexes are ubiquitous and play essential roles in many biological mechanisms. Single molecule imaging techniques such as electron microscopy (EM) and atomic force microscopy (AFM) are powerful methods for characterizing the structural properties of multi-protein and multi-protein-DNA complexes. However, a significant limitation to these techniques is the ability to distinguish different proteins from one another. Here, we combine high resolution fluorescence microscopy and AFM (FIONA-AFM) to allow the identification of different proteins in such complexes. Using quantum dots as fiducial markers in addition to fluorescently labeled proteins, we are able to align fluorescence and AFM information to ≥8 nm accuracy. This accuracy is sufficient to identify individual fluorescently labeled proteins in most multi-protein complexes. We investigate the limitations of localization precision and accuracy in fluorescence and AFM images separately and their effects on the overall registration accuracy of FIONA-AFM hybrid images. This combination of the two orthogonal techniques (FIONA and AFM) opens a wide spectrum of possible applications to the study of protein interactions, because AFM can yield high resolution (5-10 nm) information about the conformational properties of multi-protein complexes and the fluorescence can indicate spatial relationships of the proteins in the complexes. -- Research highlights: → Integration of fluorescent signals in AFM topography with high (<10 nm) accuracy. → Investigation of limitations and quantitative analysis of fluorescence-AFM image registration using quantum dots. → Fluorescence center tracking and display as localization probability distributions in AFM topography (FIONA-AFM). → Application of FIONA-AFM to a biological sample containing damaged DNA and the DNA repair proteins UvrA and UvrB conjugated to quantum dots.

  17. High Accuracy Transistor Compact Model Calibrations

    Energy Technology Data Exchange (ETDEWEB)

    Hembree, Charles E. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Mar, Alan [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Robertson, Perry J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    Typically, transistors are modeled by the application of calibrated nominal and range models. These models consists of differing parameter values that describe the location and the upper and lower limits of a distribution of some transistor characteristic such as current capacity. Correspond- ingly, when using this approach, high degrees of accuracy of the transistor models are not expected since the set of models is a surrogate for a statistical description of the devices. The use of these types of models describes expected performances considering the extremes of process or transistor deviations. In contrast, circuits that have very stringent accuracy requirements require modeling techniques with higher accuracy. Since these accurate models have low error in transistor descriptions, these models can be used to describe part to part variations as well as an accurate description of a single circuit instance. Thus, models that meet these stipulations also enable the calculation of quantifi- cation of margins with respect to a functional threshold and uncertainties in these margins. Given this need, new model high accuracy calibration techniques for bipolar junction transis- tors have been developed and are described in this report.

  18. Precise Absolute Astrometry from the VLBA Imaging and Polarimetry Survey at 5 GHz

    Science.gov (United States)

    Petrov, L.; Taylor, G. B.

    2011-01-01

    We present accurate positions for 857 sources derived from the astrometric analysis of 16 eleven-hour experiments from the Very Long Baseline Array imaging and polarimetry survey at 5 GHz (VIPS). Among the observed sources, positions of 430 objects were not previously determined at milliarcsecond-level accuracy. For 95% of the sources the uncertainty of their positions ranges from 0.3 to 0.9 mas, with a median value of 0.5 mas. This estimate of accuracy is substantiated by the comparison of positions of 386 sources that were previously observed in astrometric programs simultaneously at 2.3/8.6 GHz. Surprisingly, the ionosphere contribution to group delay was adequately modeled with the use of the total electron content maps derived from GPS observations and only marginally affected estimates of source coordinates.

  19. PRECISE ABSOLUTE ASTROMETRY FROM THE VLBA IMAGING AND POLARIMETRY SURVEY AT 5 GHz

    International Nuclear Information System (INIS)

    Petrov, L.; Taylor, G. B.

    2011-01-01

    We present accurate positions for 857 sources derived from the astrometric analysis of 16 eleven-hour experiments from the Very Long Baseline Array imaging and polarimetry survey at 5 GHz (VIPS). Among the observed sources, positions of 430 objects were not previously determined at milliarcsecond-level accuracy. For 95% of the sources the uncertainty of their positions ranges from 0.3 to 0.9 mas, with a median value of 0.5 mas. This estimate of accuracy is substantiated by the comparison of positions of 386 sources that were previously observed in astrometric programs simultaneously at 2.3/8.6 GHz. Surprisingly, the ionosphere contribution to group delay was adequately modeled with the use of the total electron content maps derived from GPS observations and only marginally affected estimates of source coordinates.

  20. Astrometric tests of General Relativity in the Solar system

    International Nuclear Information System (INIS)

    Gai, M; Vecchiato, A; Riva, A; Lattanzi, M G; Sozzetti, A; Crosta, M T; Busonero, D

    2014-01-01

    Micro-arcsec astronomy is able to verify the predictions of theoretical models of gravitation at a level adequate to constraint relevant parameters and select among different formulations. In particular, this concerns the weak field limit applicable to the Sun neighborhood, where competing models can be expressed in a common framework as the Parametrised Post-Newtonian and Parametrised Post-Post-Newtonian formulations. The mission Gaia is going to provide an unprecedented determination of the γ PPN parameter at the 10 −6 level. Other recently proposed concepts, as GAME, may improve the precision on γ by one or two orders of magnitude and provide constraints on other crucial phenomenological aspects. We review the key concepts of astrometric tests of General Relativity and discuss a possible development scenario

  1. Radial velocity observations of VB10

    Science.gov (United States)

    Deshpande, R.; Martin, E.; Zapatero Osorio, M. R.; Del Burgo, C.; Rodler, F.; Montgomery, M. M.

    2011-07-01

    VB 10 is the smallest star known to harbor a planet according to the recent astrometric study of Pravdo & Shaklan [1]. Here we present near-infrared (J-band) radial velocity of VB 10 performed from high resolution (R~20,000) spectroscopy (NIRSPEC/KECK II). Our results [2] suggest radial velocity variability with amplitude of ~1 km/s, a result that is consistent with the presence of a massive planet companion around VB10 as found via long-term astrometric monitoring of the star by Pravdo & Shaklan. Employing an entirely different technique we verify the results of Pravdo & Shaklan.

  2. Iterative methods used in overlap astrometric reduction techniques do not always converge

    Science.gov (United States)

    Rapaport, M.; Ducourant, C.; Colin, J.; Le Campion, J. F.

    1993-04-01

    In this paper we prove that the classical Gauss-Seidel type iterative methods used for the solution of the reduced normal equations occurring in overlapping reduction methods of astrometry do not always converge. We exhibit examples of divergence. We then analyze an alternative algorithm proposed by Wang (1985). We prove the consistency of this algorithm and verify that it can be convergent while the Gauss-Seidel method is divergent. We conjecture the convergence of Wang method for the solution of astrometric problems using overlap techniques.

  3. Fizeau interferometry from space: a challenging frontier in global astrometry

    Science.gov (United States)

    Loreggia, Davide; Gardiol, Daniele; Gai, Mario; Lattanzi, Mario G.; Busonero, Deborah

    2004-10-01

    The design and performance of a Fizeau interferometer with long focal length and large field of view are discussed. The optical scheme presented is well suited for very accurate astrometric measurements from space, being optimised, in terms of geometry and aberrations, to observe astronomical targets down to the visual magnitude mV=20, with a measurement accuracy of 10 microarcseconds at mV=15. This study is in the context of the next generation astrometric space missions, in particular for a mission profile similar to that of the Gaia mission of the European Space Agency. Beyond the accuracy goal, the great effort in optical aberrations reduction, particularly distortion, aims at the optimal exploitation of data acquisition done with CCD arrays working in Time Delay Integration mode. The design solution we present reaches the astrometric goals with a field of view of 0.5 square degrees.

  4. Analyses of the Short Periodical Part of the Spectrum of Pole Coordinate Variations Determined by the Astrometric and Laser Technique

    Science.gov (United States)

    Kołaczek, B.; Kosek, W.; Galas, R.

    Series of BIH astrometric (BIH-ASTR) pole coordinates and of CSR LAGEOS laser ranging (CSR-LALAR) pole coordinates determined in the MERIT Campaign in the years 1972 - 1986, 1983 - 1986, respectively, have been filtered by different band pass filters consisting of the law pass Gauss filter and of the high pass Butterworth filter. Filtered residuals were analysed by the MESA-Maximum Entropy Spectra Analysis and by the Ormsby narrow band pass filters in order to find numerically modeled signals approximating these residuals in the best way.

  5. The use of low density high accuracy (LDHA) data for correction of high density low accuracy (HDLA) point cloud

    Science.gov (United States)

    Rak, Michal Bartosz; Wozniak, Adam; Mayer, J. R. R.

    2016-06-01

    Coordinate measuring techniques rely on computer processing of coordinate values of points gathered from physical surfaces using contact or non-contact methods. Contact measurements are characterized by low density and high accuracy. On the other hand optical methods gather high density data of the whole object in a short time but with accuracy at least one order of magnitude lower than for contact measurements. Thus the drawback of contact methods is low density of data, while for non-contact methods it is low accuracy. In this paper a method for fusion of data from two measurements of fundamentally different nature: high density low accuracy (HDLA) and low density high accuracy (LDHA) is presented to overcome the limitations of both measuring methods. In the proposed method the concept of virtual markers is used to find a representation of pairs of corresponding characteristic points in both sets of data. In each pair the coordinates of the point from contact measurements is treated as a reference for the corresponding point from non-contact measurement. Transformation enabling displacement of characteristic points from optical measurement to their match from contact measurements is determined and applied to the whole point cloud. The efficiency of the proposed algorithm was evaluated by comparison with data from a coordinate measuring machine (CMM). Three surfaces were used for this evaluation: plane, turbine blade and engine cover. For the planar surface the achieved improvement was of around 200 μm. Similar results were obtained for the turbine blade but for the engine cover the improvement was smaller. For both freeform surfaces the improvement was higher for raw data than for data after creation of mesh of triangles.

  6. Strong tidal dissipation in Io and Jupiter from astrometric observations.

    Science.gov (United States)

    Lainey, Valéry; Arlot, Jean-Eudes; Karatekin, Ozgür; Van Hoolst, Tim

    2009-06-18

    Io is the volcanically most active body in the Solar System and has a large surface heat flux. The geological activity is thought to be the result of tides raised by Jupiter, but it is not known whether the current tidal heat production is sufficiently high to generate the observed surface heat flow. Io's tidal heat comes from the orbital energy of the Io-Jupiter system (resulting in orbital acceleration), whereas dissipation of energy in Jupiter causes Io's orbital motion to decelerate. Here we report a determination of the tidal dissipation in Io and Jupiter through its effect on the orbital motions of the Galilean moons. Our results show that the rate of internal energy dissipation in Io (k(2)/Q = 0.015 +/- 0.003, where k(2) is the Love number and Q is the quality factor) is in good agreement with the observed surface heat flow, and suggest that Io is close to thermal equilibrium. Dissipation in Jupiter (k(2)/Q = (1.102 +/- 0.203) x 10(-5)) is close to the upper bound of its average value expected from the long-term evolution of the system, and dissipation in extrasolar planets may be higher than presently assumed. The measured secular accelerations indicate that Io is evolving inwards, towards Jupiter, and that the three innermost Galilean moons (Io, Europa and Ganymede) are evolving out of the exact Laplace resonance.

  7. Improvement of the accuracy of phase observation by modification of phase-shifting electron holography

    International Nuclear Information System (INIS)

    Suzuki, Takahiro; Aizawa, Shinji; Tanigaki, Toshiaki; Ota, Keishin; Matsuda, Tsuyoshi; Tonomura, Akira

    2012-01-01

    We found that the accuracy of the phase observation in phase-shifting electron holography is strongly restricted by time variations of mean intensity and contrast of the holograms. A modified method was developed for correcting these variations. Experimental results demonstrated that the modification enabled us to acquire a large number of holograms, and as a result, the accuracy of the phase observation has been improved by a factor of 5. -- Highlights: ► A modified phase-shifting electron holography was proposed. ► The time variation of mean intensity and contrast of holograms were corrected. ► These corrections lead to a great improvement of the resultant phase accuracy. ► A phase accuracy of about 1/4000 rad was achieved from experimental results.

  8. The "Quasar" Network Observations in e-VLBI Mode Within the Russian Domestic VLBI Programs

    Science.gov (United States)

    Finkelstein, Andrey; Ipatov, Alexander; Kaidanovsky, Michael; Bezrukov, Ilia; Mikhailov, Andrey; Salnikov, Alexander; Surkis, Igor; Skurikhina, Elena

    2010-01-01

    The purpose of the Russian VLBI "Quasar" Network is to carry out astrometrical and geodynamical investigations. Since 2006 purely domestic observational programs with data processing at the IAA correlator have been carried out. To maintain these geodynamical programs e-VLBI technology is being developed and tested. This paper describes the IAA activity of developing a real-time VLBI system using high-speed digital communication links.

  9. Diagnostic accuracy of high-definition CT coronary angiography in high-risk patients

    International Nuclear Information System (INIS)

    Iyengar, S.S.; Morgan-Hughes, G.; Ukoumunne, O.; Clayton, B.; Davies, E.J.; Nikolaou, V.; Hyde, C.J.; Shore, A.C.; Roobottom, C.A.

    2016-01-01

    Aim: To assess the diagnostic accuracy of computed tomography coronary angiography (CTCA) using a combination of high-definition CT (HD-CTCA) and high level of reader experience, with invasive coronary angiography (ICA) as the reference standard, in high-risk patients for the investigation of coronary artery disease (CAD). Materials and methods: Three hundred high-risk patients underwent HD-CTCA and ICA. Independent experts evaluated the images for the presence of significant CAD, defined primarily as the presence of moderate (≥50%) stenosis and secondarily as the presence of severe (≥70%) stenosis in at least one coronary segment, in a blinded fashion. HD-CTCA was compared to ICA as the reference standard. Results: No patients were excluded. Two hundred and six patients (69%) had moderate and 178 (59%) had severe stenosis in at least one vessel at ICA. The sensitivity, specificity, positive predictive value, and negative predictive value were 97.1%, 97.9%, 99% and 93.9% for moderate stenosis, and 98.9%, 93.4%, 95.7% and 98.3%, for severe stenosis, on a per-patient basis. Conclusion: The combination of HD-CTCA and experienced readers applied to a high-risk population, results in high diagnostic accuracy comparable to ICA. Modern generation CT systems in experienced hands might be considered for an expanded role. - Highlights: • Diagnostic accuracy of High-Definition CT Angiography (HD-CTCA) has been assessed. • Invasive Coronary angiography (ICA) is the reference standard. • Diagnostic accuracy of HD-CTCA is comparable to ICA. • Diagnostic accuracy is not affected by coronary calcium or stents. • HD-CTCA provides a non-invasive alternative in high-risk patients.

  10. LBT observations of the HR8799 planetary system

    Science.gov (United States)

    Mesa, D.; Arcidiacono, C.; Claudi, R. U.; Desidera, S.; Esposito, S.; Gratton, R.; Masciadri, E.

    2013-09-01

    We present here observations of the HR8799 planetary system performed in H and Ks band exploiting the AO system at the Large Binocular Telescope and the PISCES camera. Thanks to the excellent performence of the instrument we were able to detect for the first time the inner known planet of the system (HR8799) in the H band. Precise photometric and astrometric measures have been taken for all the four planets. Further, exploiting ours and previous astrometric results, we were able to put some limits on the planetary orbits of the four planets. The analysis of the dinamical stability of the system seems to show lower planetary masses than the ones adopted until now.

  11. Improvement of the accuracy of phase observation by modification of phase-shifting electron holography

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Takahiro; Aizawa, Shinji; Tanigaki, Toshiaki [Advanced Science Institute, RIKEN, Hirosawa 2-1, Wako, Saitama 351-0198 (Japan); Ota, Keishin, E-mail: ota@microphase.co.jp [Microphase Co., Ltd., Onigakubo 1147-9, Tsukuba, Ibaragi 300-2651 (Japan); Matsuda, Tsuyoshi [Japan Science and Technology Agency, Kawaguchi-shi, Saitama 332-0012 (Japan); Tonomura, Akira [Advanced Science Institute, RIKEN, Hirosawa 2-1, Wako, Saitama 351-0198 (Japan); Okinawa Institute of Science and Technology, Graduate University, Kunigami, Okinawa 904-0495 (Japan); Central Research Laboratory, Hitachi, Ltd., Hatoyama, Saitama 350-0395 (Japan)

    2012-07-15

    We found that the accuracy of the phase observation in phase-shifting electron holography is strongly restricted by time variations of mean intensity and contrast of the holograms. A modified method was developed for correcting these variations. Experimental results demonstrated that the modification enabled us to acquire a large number of holograms, and as a result, the accuracy of the phase observation has been improved by a factor of 5. -- Highlights: Black-Right-Pointing-Pointer A modified phase-shifting electron holography was proposed. Black-Right-Pointing-Pointer The time variation of mean intensity and contrast of holograms were corrected. Black-Right-Pointing-Pointer These corrections lead to a great improvement of the resultant phase accuracy. Black-Right-Pointing-Pointer A phase accuracy of about 1/4000 rad was achieved from experimental results.

  12. Systematic Calibration for Ultra-High Accuracy Inertial Measurement Units

    Directory of Open Access Journals (Sweden)

    Qingzhong Cai

    2016-06-01

    Full Text Available An inertial navigation system (INS has been widely used in challenging GPS environments. With the rapid development of modern physics, an atomic gyroscope will come into use in the near future with a predicted accuracy of 5 × 10−6°/h or better. However, existing calibration methods and devices can not satisfy the accuracy requirements of future ultra-high accuracy inertial sensors. In this paper, an improved calibration model is established by introducing gyro g-sensitivity errors, accelerometer cross-coupling errors and lever arm errors. A systematic calibration method is proposed based on a 51-state Kalman filter and smoother. Simulation results show that the proposed calibration method can realize the estimation of all the parameters using a common dual-axis turntable. Laboratory and sailing tests prove that the position accuracy in a five-day inertial navigation can be improved about 8% by the proposed calibration method. The accuracy can be improved at least 20% when the position accuracy of the atomic gyro INS can reach a level of 0.1 nautical miles/5 d. Compared with the existing calibration methods, the proposed method, with more error sources and high order small error parameters calibrated for ultra-high accuracy inertial measurement units (IMUs using common turntables, has a great application potential in future atomic gyro INSs.

  13. Update on Astrometric Follow-Up at Apache Point Observatory by Adler Planetarium

    Science.gov (United States)

    Nault, Kristie A.; Brucker, Melissa; Hammergren, Mark

    2016-10-01

    We began our NEO astrometric follow-up and characterization program in 2014 Q4 using about 500 hours of observing time per year with the Astrophysical Research Consortium (ARC) 3.5m telescope at Apache Point Observatory (APO). Our observing is split into 2 hour blocks approximately every other night for astrometry (this poster) and several half-nights per month for spectroscopy (see poster by M. Hammergren et al.) and light curve studies.For astrometry, we use the ARC Telescope Imaging Camera (ARCTIC) with an SDSS r filter, in 2 hour observing blocks centered around midnight. ARCTIC has a magnitude limit of V~23 in 60s, and we target 20 NEOs per session. ARCTIC has a FOV 1.57 times larger and a readout time half as long as the previous imager, SPIcam, which we used from 2014 Q4 through 2015 Q3. Targets are selected primarily from the Minor Planet Center's (MPC) NEO Confirmation Page (NEOCP), and NEA Observation Planning Aid; we also refer to JPL's What's Observable page, the Spaceguard Priority List and Faint NEOs List, and requests from other observers. To quickly adapt to changing weather and seeing conditions, we create faint, midrange, and bright target lists. Detected NEOs are measured with Astrometrica and internal software, and the astrometry is reported to the MPC.As of June 19, 2016, we have targeted 2264 NEOs, 1955 with provisional designations, 1582 of which were detected. We began observing NEOCP asteroids on January 30, 2016, and have targeted 309, 207 of which were detected. In addition, we serendipitously observed 281 moving objects, 201 of which were identified as previously known objects.This work is based on observations obtained with the Apache Point Observatory 3.5m telescope, which is owned and operated by the Astrophysical Research Consortium. We gratefully acknowledge support from NASA NEOO award NNX14AL17G and thank the University of Chicago Department of Astronomy and Astrophysics for observing time in 2014.

  14. Parietal and premotor cortices: activation reflects imitation accuracy during observation, delayed imitation and concurrent imitation.

    Science.gov (United States)

    Krüger, Britta; Bischoff, Matthias; Blecker, Carlo; Langhanns, Christine; Kindermann, Stefan; Sauerbier, Isabell; Reiser, Mathias; Stark, Rudolf; Munzert, Jörn; Pilgramm, Sebastian

    2014-10-15

    This study investigated whether activation within areas belonging to the action observation and imitation network reveals a linear relation to the subsequent accuracy of imitating a bimanual rhythmic movement measured via a motion capturing system. 20 participants were scanned with functional magnetic resonance imaging (fMRI) when asked to imitate observed bimanual movements either concurrently versus with a delay (2s) or simply to observe the movements without imitation. Results showed that action observation relates to activation within classic mirror-related areas. Activation patterns were more widespread when participants were asked to imitate the movement. During observation with concurrent imitation, activation in the left inferior parietal lobe (IPL) was associated negatively with imitation accuracy. During observation in the delayed imitation condition, higher subsequent imitation accuracy was coupled with higher activation in the right superior parietal lobe (SPL) and the left parietal operculum (POp). During the delayed imitation itself, a negative association between imitation accuracy and brain activation was revealed in the right ventral premotor cortex (vPMC). We conclude that the IPL is involved in online comparison and visuospatial attention processes during imitation, the SPL provides a kinesthetic blueprint during movement observation, the POp preserves body identity, and the vPMC recruits motor representations--especially when no concurrent visual guidance is possible. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Inversions of High-Cadence SOLIS-VSM Stokes Observations

    NARCIS (Netherlands)

    Fischer, C.E.; Keller, C.U.; Snik, F.

    2008-01-01

    We have processed full-Stokes observations made with the SOLIS-VSM using Fe I 630.15 and Fe I 630.25 nm. The data have high spectral and temporal resolution, moderate spatial resolution, and large polarimetric sensitivity and accuracy. We use the code LILIA, an LTE inversion code written by

  16. Observations of Anomalous Refraction with Co-housed Telescopes

    Science.gov (United States)

    Taylor, Malinda S.; McGraw, J. T.; Zimmer, P. C.

    2013-01-01

    Anomalous refraction is described as a low frequency, large angular scale motion of the entire image plane with respect to the celestial coordinate system as observed and defined by previous astrometric catalogs. These motions of typically several tenths of an arcsecond with timescales on the order of ten minutes are ubiquitous to drift-scan ground-based astrometric measurements regardless of location or telescopes used and have been attributed to meter scale slowly evolving coherent dynamical structures in the boundary-layer below 60 meters. The localized nature of the effect and general inconsistency of the motions seen by even closely spaced telescopes in individual domes has led to the hypothesis that the dome or other type of telescope housing may be responsible. This hypothesis is tested by observing anomalous refraction using two telescopes housed in a single roll-off roof observatory building with the expected outcome that the two telescopes will see correlated anomalous refraction induced motions.

  17. High-accuracy measurement of ship velocities by DGPS; DGPS ni yoru sensoku keisoku no koseidoka ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, S; Koterayama, W [Kyushu Univ., Fukuoka (Japan). Research Inst. for Applied Mechanics

    1996-04-10

    The differential global positioning system (DGPS) can eliminate most of errors in ship velocity measurement by GPS positioning alone. Through two rounds of marine observations by towing an observation robot in summer 1995, the authors attempted high-accuracy measurement of ship velocities by DGPS, and also carried out both positioning by GPS alone and measurement using the bottom track of ADCP (acoustic Doppler current profiler). In this paper, the results obtained by these measurement methods were examined through comparison among them, and the accuracy of the measured ship velocities was considered. In DGPS measurement, both translocation method and interference positioning method were used. ADCP mounted on the observation robot allowed measurement of the velocity of current meter itself by its bottom track in shallow sea areas less than 350m. As the result of these marine observations, it was confirmed that the accuracy equivalent to that of direct measurement by bottom track is possible to be obtained by DGPS. 3 refs., 5 figs., 1 tab.

  18. Research on Horizontal Accuracy Method of High Spatial Resolution Remotely Sensed Orthophoto Image

    Science.gov (United States)

    Xu, Y. M.; Zhang, J. X.; Yu, F.; Dong, S.

    2018-04-01

    At present, in the inspection and acceptance of high spatial resolution remotly sensed orthophoto image, the horizontal accuracy detection is testing and evaluating the accuracy of images, which mostly based on a set of testing points with the same accuracy and reliability. However, it is difficult to get a set of testing points with the same accuracy and reliability in the areas where the field measurement is difficult and the reference data with high accuracy is not enough. So it is difficult to test and evaluate the horizontal accuracy of the orthophoto image. The uncertainty of the horizontal accuracy has become a bottleneck for the application of satellite borne high-resolution remote sensing image and the scope of service expansion. Therefore, this paper proposes a new method to test the horizontal accuracy of orthophoto image. This method using the testing points with different accuracy and reliability. These points' source is high accuracy reference data and field measurement. The new method solves the horizontal accuracy detection of the orthophoto image in the difficult areas and provides the basis for providing reliable orthophoto images to the users.

  19. Diagnostic Accuracy and Inter-Observer Agreement of Shoulder Magnetic Resonance Arthrography in the Detection of Labral Lesion and Assessment of Lesion Location

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young; Song, Sook Yun; Choi, Jin Ha; Shin, Sang Jin [School of Medicine, Ewha Womans University, Mokdong Hospital, Seoul (Korea, Republic of)

    2012-11-15

    To evaluate the diagnostic accuracy and inter-observer agreement of magnetic resonance (MR) arthrography in the detection of labral lesions by location and to describe useful MR imaging findings of labral tears. Sixty-eight patients who underwent both pre-operative MR arthrography and arthroscopy were included. The location of the labrum was classified into anterior (2-6 o'clock), superior (12-2 o'clock), and posterior (6-12 o'clock). Sensitivity, specificity, accuracy, and inter-observer agreement of MR arthrography for the diagnosis of labral lesions by location were calculated. Frequency of MR imaging findings such as detachment, high signal intensity cleft, contour change, absence, and signal change of the labrum by location were analyzed. 35 anterior, 44 superior and 15 posterior labral lesions were detected by arthroscopy. The corresponding sensitivities were 91.4%, 79.5%, and 40.0%, specificities were 90.9%, 20.8%, and 86.8%, accuracies were 91.2%, 58.8%, and 76.5%, and kappa values were 0.823, 0.252, and 0.394, for anterior, superior, posterior lesions, respectively. The most common MR imaging findings were detachment in 60.0% of anterior labrums, high signal intensity cleft in 52.3% of superior labrums, and normal in 60.0% of posterior labrums. Diagnostic accuracy and inter-observer agreement of MR arthrography in the diagnosis of labral lesions are high in anterior labrums and low in superior or posterior labrums. The useful MR imaging findings of labral tears were different according to labral location.

  20. High accuracy 3-D laser radar

    DEFF Research Database (Denmark)

    Busck, Jens; Heiselberg, Henning

    2004-01-01

    We have developed a mono-static staring 3-D laser radar based on gated viewing with range accuracy below 1 m at 10 m and 1 cm at 100. We use a high sensitivity, fast, intensified CCD camera, and a Nd:Yag passively Q-switched 32.4 kHz pulsed green laser at 532 nm. The CCD has 752x582 pixels. Camera...

  1. High accuracy autonomous navigation using the global positioning system (GPS)

    Science.gov (United States)

    Truong, Son H.; Hart, Roger C.; Shoan, Wendy C.; Wood, Terri; Long, Anne C.; Oza, Dipak H.; Lee, Taesul

    1997-01-01

    The application of global positioning system (GPS) technology to the improvement of the accuracy and economy of spacecraft navigation, is reported. High-accuracy autonomous navigation algorithms are currently being qualified in conjunction with the GPS attitude determination flyer (GADFLY) experiment for the small satellite technology initiative Lewis spacecraft. Preflight performance assessments indicated that these algorithms are able to provide a real time total position accuracy of better than 10 m and a velocity accuracy of better than 0.01 m/s, with selective availability at typical levels. It is expected that the position accuracy will be increased to 2 m if corrections are provided by the GPS wide area augmentation system.

  2. Another look at AM Herculis - radio-astrometric campaign with the e-EVN at 6 cm

    Science.gov (United States)

    Gawroński, M. P.; Goździewski, K.; Katarzyński, K.; Rycyk, G.

    2018-03-01

    We conducted radio-interferometric observations of the well-known binary cataclysmic system AM Herculis. This particular system is formed from a magnetic white dwarf (primary) and a red dwarf (secondary), and it is the prototype of so-called polars. Our observations were conducted with the European VLBI Network (EVN) in e-EVN mode at 5 GHz. We obtained six astrometric measurements spanning 1 yr, which make it possible to update the annual parallax for this system with the best precision to date (π = 11.29 ± 0.08 mas), which is equivalent to a distance of 88.6 ± 0.6 pc. The system was observed mostly in the quiescent phase (visual magnitude mv ˜ 15.3), when the radio emission was at the level of about 300 μJy. Our analysis suggests that the radio flux of AM Herculis is modulated with the orbital motion. Such specific properties of the radiation can be explained using an emission mechanism like the scenario proposed for V471 Tau and, in general, for RS CVn-type stars. In this scenario, the radio emission arises near the surface of the red dwarf, where the global magnetic field strength may reach a few kG. We argue that the quiescent radio emission distinguishes AM Herculis and AR Ursae Majoris (a second known persistent radio polar) from other polars, which are systems with a magnetized secondary star.

  3. High accuracy wavelength calibration for a scanning visible spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Scotti, Filippo; Bell, Ronald E. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)

    2010-10-15

    Spectroscopic applications for plasma velocity measurements often require wavelength accuracies {<=}0.2 A. An automated calibration, which is stable over time and environmental conditions without the need to recalibrate after each grating movement, was developed for a scanning spectrometer to achieve high wavelength accuracy over the visible spectrum. This method fits all relevant spectrometer parameters using multiple calibration spectra. With a stepping-motor controlled sine drive, an accuracy of {approx}0.25 A has been demonstrated. With the addition of a high resolution (0.075 arc sec) optical encoder on the grating stage, greater precision ({approx}0.005 A) is possible, allowing absolute velocity measurements within {approx}0.3 km/s. This level of precision requires monitoring of atmospheric temperature and pressure and of grating bulk temperature to correct for changes in the refractive index of air and the groove density, respectively.

  4. Switched-capacitor techniques for high-accuracy filter and ADC design

    NARCIS (Netherlands)

    Quinn, P.J.; Roermund, van A.H.M.

    2007-01-01

    Switched capacitor (SC) techniques are well proven to be excellent candidates for implementing critical analogue functions with high accuracy, surpassing other analogue techniques when embedded in mixed-signal CMOS VLSI. Conventional SC circuits are primarily limited in accuracy by a) capacitor

  5. Observing and Measuring Visual Double Stars

    CERN Document Server

    2013-01-01

    In these days of high-precision astrometric satellites, tremendous contributions to the science of astrometry are being made by amateur astronomers around the globe. This second edition of Observing and Measuring Visual Double Stars contains a significant amount of completely new material inspired by the work done by observers - particularly in the USA - since the first edition was published. Fifteen skilled and experienced astronomers have contributed chapters on their own specialization in the various fields. These include how to use the Internet to carry out precise astronomical measurement, an excellent guide to sketching double stars, and information on how to image double stars of unequal brightness. This new edition is the definitive book for those who are serious about this fascinating aspect of astronomy! Author Bob Argyle has been observing visual double stars for more than 40 years, some with the help of the world's biggest refractors, and has been director of the Webb Society Double Star Se...

  6. High-accuracy mass spectrometry for fundamental studies.

    Science.gov (United States)

    Kluge, H-Jürgen

    2010-01-01

    Mass spectrometry for fundamental studies in metrology and atomic, nuclear and particle physics requires extreme sensitivity and efficiency as well as ultimate resolving power and accuracy. An overview will be given on the global status of high-accuracy mass spectrometry for fundamental physics and metrology. Three quite different examples of modern mass spectrometric experiments in physics are presented: (i) the retardation spectrometer KATRIN at the Forschungszentrum Karlsruhe, employing electrostatic filtering in combination with magnetic-adiabatic collimation-the biggest mass spectrometer for determining the smallest mass, i.e. the mass of the electron anti-neutrino, (ii) the Experimental Cooler-Storage Ring at GSI-a mass spectrometer of medium size, relative to other accelerators, for determining medium-heavy masses and (iii) the Penning trap facility, SHIPTRAP, at GSI-the smallest mass spectrometer for determining the heaviest masses, those of super-heavy elements. Finally, a short view into the future will address the GSI project HITRAP at GSI for fundamental studies with highly-charged ions.

  7. Accuracy Assessment for the Three-Dimensional Coordinates by High-Speed Videogrammetric Measurement

    Directory of Open Access Journals (Sweden)

    Xianglei Liu

    2018-01-01

    Full Text Available High-speed CMOS camera is a new kind of transducer to make the videogrammetric measurement for monitoring the displacement of high-speed shaking table structure. The purpose of this paper is to validate the three-dimensional coordinate accuracy of the shaking table structure acquired from the presented high-speed videogrammetric measuring system. In the paper, all of the key intermediate links are discussed, including the high-speed CMOS videogrammetric measurement system, the layout of the control network, the elliptical target detection, and the accuracy validation of final 3D spatial results. Through the accuracy analysis, the submillimeter accuracy can be made for the final the three-dimensional spatial coordinates which certify that the proposed high-speed videogrammetric technique is a better alternative technique which can replace the traditional transducer technique for monitoring the dynamic response for the shaking table structure.

  8. An angle encoder for super-high resolution and super-high accuracy using SelfA

    Science.gov (United States)

    Watanabe, Tsukasa; Kon, Masahito; Nabeshima, Nobuo; Taniguchi, Kayoko

    2014-06-01

    Angular measurement technology at high resolution for applications such as in hard disk drive manufacturing machines, precision measurement equipment and aspherical process machines requires a rotary encoder with high accuracy, high resolution and high response speed. However, a rotary encoder has angular deviation factors during operation due to scale error or installation error. It has been assumed to be impossible to achieve accuracy below 0.1″ in angular measurement or control after the installation onto the rotating axis. Self-calibration (Lu and Trumper 2007 CIRP Ann. 56 499; Kim et al 2011 Proc. MacroScale; Probst 2008 Meas. Sci. Technol. 19 015101; Probst et al Meas. Sci. Technol. 9 1059; Tadashi and Makoto 1993 J. Robot. Mechatronics 5 448; Ralf et al 2006 Meas. Sci. Technol. 17 2811) and cross-calibration (Probst et al 1998 Meas. Sci. Technol. 9 1059; Just et al 2009 Precis. Eng. 33 530; Burnashev 2013 Quantum Electron. 43 130) technologies for a rotary encoder have been actively discussed on the basis of the principle of circular closure. This discussion prompted the development of rotary tables which achieve reliable and high accuracy angular verification. We apply these technologies for the development of a rotary encoder not only to meet the requirement of super-high accuracy but also to meet that of super-high resolution. This paper presents the development of an encoder with 221 = 2097 152 resolutions per rotation (360°), that is, corresponding to a 0.62″ signal period, achieved by the combination of a laser rotary encoder supplied by Magnescale Co., Ltd and a self-calibratable encoder (SelfA) supplied by The National Institute of Advanced Industrial Science & Technology (AIST). In addition, this paper introduces the development of a rotary encoder to guarantee ±0.03″ accuracy at any point of the interpolated signal, with respect to the encoder at the minimum resolution of 233, that is, corresponding to a 0.0015″ signal period after

  9. High-accuracy determination of the neutron flux at n{sub T}OF

    Energy Technology Data Exchange (ETDEWEB)

    Barbagallo, M.; Colonna, N.; Mastromarco, M.; Meaze, M.; Tagliente, G.; Variale, V. [Sezione di Bari, INFN, Bari (Italy); Guerrero, C.; Andriamonje, S.; Boccone, V.; Brugger, M.; Calviani, M.; Cerutti, F.; Chin, M.; Ferrari, A.; Kadi, Y.; Losito, R.; Versaci, R.; Vlachoudis, V. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Tsinganis, A. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); National Technical University of Athens (NTUA), Athens (Greece); Tarrio, D.; Duran, I.; Leal-Cidoncha, E.; Paradela, C. [Universidade de Santiago de Compostela, Santiago (Spain); Altstadt, S.; Goebel, K.; Langer, C.; Reifarth, R.; Schmidt, S.; Weigand, M. [Johann-Wolfgang-Goethe Universitaet, Frankfurt (Germany); Andrzejewski, J.; Marganiec, J.; Perkowski, J. [Uniwersytet Lodzki, Lodz (Poland); Audouin, L.; Leong, L.S.; Tassan-Got, L. [Centre National de la Recherche Scientifique/IN2P3 - IPN, Orsay (France); Becares, V.; Cano-Ott, D.; Garcia, A.R.; Gonzalez-Romero, E.; Martinez, T.; Mendoza, E. [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain); Becvar, F.; Krticka, M.; Kroll, J.; Valenta, S. [Charles University, Prague (Czech Republic); Belloni, F.; Fraval, K.; Gunsing, F.; Lampoudis, C.; Papaevangelou, T. [Commissariata l' Energie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette (France); Berthoumieux, E.; Chiaveri, E. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Commissariata l' Energie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette (France); Billowes, J.; Ware, T.; Wright, T. [University of Manchester, Manchester (United Kingdom); Bosnar, D.; Zugec, P. [University of Zagreb, Department of Physics, Faculty of Science, Zagreb (Croatia); Calvino, F.; Cortes, G.; Gomez-Hornillos, M.B.; Riego, A. [Universitat Politecnica de Catalunya, Barcelona (Spain); Carrapico, C.; Goncalves, I.F.; Sarmento, R.; Vaz, P. [Universidade Tecnica de Lisboa, Instituto Tecnologico e Nuclear, Instituto Superior Tecnico, Lisboa (Portugal); Cortes-Giraldo, M.A.; Praena, J.; Quesada, J.M.; Sabate-Gilarte, M. [Universidad de Sevilla, Sevilla (Spain); Diakaki, M.; Karadimos, D.; Kokkoris, M.; Vlastou, R. [National Technical University of Athens (NTUA), Athens (Greece); Domingo-Pardo, C.; Giubrone, G.; Tain, J.L. [CSIC-Universidad de Valencia, Instituto de Fisica Corpuscular, Valencia (Spain); Dressler, R.; Kivel, N.; Schumann, D.; Steinegger, P. [Paul Scherrer Institut, Villigen PSI (Switzerland); Dzysiuk, N.; Mastinu, P.F. [Laboratori Nazionali di Legnaro, INFN, Rome (Italy); Eleftheriadis, C.; Manousos, A. [Aristotle University of Thessaloniki, Thessaloniki (Greece); Ganesan, S.; Gurusamy, P.; Saxena, A. [Bhabha Atomic Research Centre (BARC), Mumbai (IN); Griesmayer, E.; Jericha, E.; Leeb, H. [Technische Universitaet Wien, Atominstitut, Wien (AT); Hernandez-Prieto, A. [European Organization for Nuclear Research (CERN), Geneva (CH); Universitat Politecnica de Catalunya, Barcelona (ES); Jenkins, D.G.; Vermeulen, M.J. [University of York, Heslington, York (GB); Kaeppeler, F. [Institut fuer Kernphysik, Karlsruhe Institute of Technology, Campus Nord, Karlsruhe (DE); Koehler, P. [Oak Ridge National Laboratory (ORNL), Oak Ridge (US); Lederer, C. [Johann-Wolfgang-Goethe Universitaet, Frankfurt (DE); University of Vienna, Faculty of Physics, Vienna (AT); Massimi, C.; Mingrone, F.; Vannini, G. [Universita di Bologna (IT); INFN, Sezione di Bologna, Dipartimento di Fisica, Bologna (IT); Mengoni, A.; Ventura, A. [Agenzia nazionale per le nuove tecnologie, l' energia e lo sviluppo economico sostenibile (ENEA), Bologna (IT); Milazzo, P.M. [Sezione di Trieste, INFN, Trieste (IT); Mirea, M. [Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN HH, Bucharest - Magurele (RO); Mondalaers, W.; Plompen, A.; Schillebeeckx, P. [Institute for Reference Materials and Measurements, European Commission JRC, Geel (BE); Pavlik, A.; Wallner, A. [University of Vienna, Faculty of Physics, Vienna (AT); Rauscher, T. [University of Basel, Department of Physics and Astronomy, Basel (CH); Roman, F. [European Organization for Nuclear Research (CERN), Geneva (CH); Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN HH, Bucharest - Magurele (RO); Rubbia, C. [European Organization for Nuclear Research (CERN), Geneva (CH); Laboratori Nazionali del Gran Sasso dell' INFN, Assergi (AQ) (IT); Weiss, C. [European Organization for Nuclear Research (CERN), Geneva (CH); Johann-Wolfgang-Goethe Universitaet, Frankfurt (DE)

    2013-12-15

    The neutron flux of the n{sub T}OF facility at CERN was measured, after installation of the new spallation target, with four different systems based on three neutron-converting reactions, which represent accepted cross sections standards in different energy regions. A careful comparison and combination of the different measurements allowed us to reach an unprecedented accuracy on the energy dependence of the neutron flux in the very wide range (thermal to 1 GeV) that characterizes the n{sub T}OF neutron beam. This is a pre-requisite for the high accuracy of cross section measurements at n{sub T}OF. An unexpected anomaly in the neutron-induced fission cross section of {sup 235}U is observed in the energy region between 10 and 30keV, hinting at a possible overestimation of this important cross section, well above currently assigned uncertainties. (orig.)

  10. High precision predictions for near-Earth asteroids: the strange case of (3908) Nyx

    Science.gov (United States)

    Farnocchia, D.; Chesley, S. R.; Tholen, D. J.; Micheli, M.

    2014-08-01

    In November 2004 radar delay measurements of near-Earth asteroid (3908) Nyx obtained at the Arecibo radio telescope turned out to be away from the orbital prediction. We prove that this discrepancy was caused by a poor astrometric treatment and an incomplete dynamical model, which did not account for nongravitational perturbations. To improve the astrometric treatment, we remove known star catalog biases, apply suitable weights to the observations, and use an aggressive outlier rejection scheme. The main issue related to the dynamical model is having not accounted for the Yarkovsky effect. Including the Yarkovsky perturbation in the model makes the orbital prediction and the radar measurements statistically consistent by both reducing the offset and increasing the prediction uncertainty to a more realistic level. This analysis shows the sensitivity of high precision predictions to the astrometric treatment and the Yarkovsky effect. By using the full observational dataset we obtain a detection of the Yarkovsky effect acting on Nyx corresponding to an orbital drift m/year. In turn, we derive constraints on thermal inertia and bulk density. In particular, we find that the bulk density of Nyx is around 1 g/cm, possibly less. To make sure that our results are not corrupted by an asteroid impact or a close approach with a perturbing asteroid not included in our dynamical model, we show that the astrometry provides no convincing evidence of an impulsive variation of Nyx's velocity while crossing the main belt region.

  11. High-accuracy diagnostic tool for electron cloud observation in the LHC based on synchronous phase measurements

    CERN Document Server

    Esteban Müller, J F; Shaposhnikova, E; Valuch, D; Mastoridis, T

    2014-01-01

    Electron cloud effects such as heat load in the cryogenic system, pressure rise and beam instabilities are among the main limitations for the LHC operation with 25 ns spaced bunches. A new observation tool was developed to monitor the e-cloud activity and has been successfully used in the LHC during Run 1 (2010-2012). The power loss of each bunch due to the e-cloud can be estimated using very precise bunch-by-bunch measurement of the synchronous phase shift. In order to achieve the required accuracy, corrections for reflection in the cables and some systematic errors need to be applied followed by a post-processing of the measurements. Results clearly show the e-cloud build-up along the bunch trains and its evolution during each LHC fill as well as from fill to fill. Measurements during the 2012 LHC scrubbing run reveal a progressive reduction in the e-cloud activity and therefore a decrease in the secondary electron yield (SEY). The total beam power loss can be computed as a sum of the contributions from all...

  12. An angle encoder for super-high resolution and super-high accuracy using SelfA

    International Nuclear Information System (INIS)

    Watanabe, Tsukasa; Kon, Masahito; Nabeshima, Nobuo; Taniguchi, Kayoko

    2014-01-01

    Angular measurement technology at high resolution for applications such as in hard disk drive manufacturing machines, precision measurement equipment and aspherical process machines requires a rotary encoder with high accuracy, high resolution and high response speed. However, a rotary encoder has angular deviation factors during operation due to scale error or installation error. It has been assumed to be impossible to achieve accuracy below 0.1″ in angular measurement or control after the installation onto the rotating axis. Self-calibration (Lu and Trumper 2007 CIRP Ann. 56 499; Kim et al 2011 Proc. MacroScale; Probst 2008 Meas. Sci. Technol. 19 015101; Probst et al Meas. Sci. Technol. 9 1059; Tadashi and Makoto 1993 J. Robot. Mechatronics 5 448; Ralf et al 2006 Meas. Sci. Technol. 17 2811) and cross-calibration (Probst et al 1998 Meas. Sci. Technol. 9 1059; Just et al 2009 Precis. Eng. 33 530; Burnashev 2013 Quantum Electron. 43 130) technologies for a rotary encoder have been actively discussed on the basis of the principle of circular closure. This discussion prompted the development of rotary tables which achieve reliable and high accuracy angular verification. We apply these technologies for the development of a rotary encoder not only to meet the requirement of super-high accuracy but also to meet that of super-high resolution. This paper presents the development of an encoder with 2 21 = 2097 152 resolutions per rotation (360°), that is, corresponding to a 0.62″ signal period, achieved by the combination of a laser rotary encoder supplied by Magnescale Co., Ltd and a self-calibratable encoder (SelfA) supplied by The National Institute of Advanced Industrial Science and Technology (AIST). In addition, this paper introduces the development of a rotary encoder to guarantee ±0.03″ accuracy at any point of the interpolated signal, with respect to the encoder at the minimum resolution of 2 33 , that is, corresponding to a 0.0015″ signal period

  13. Fast and High Accuracy Wire Scanner

    CERN Document Server

    Koujili, M; Koopman, J; Ramos, D; Sapinski, M; De Freitas, J; Ait Amira, Y; Djerdir, A

    2009-01-01

    Scanning of a high intensity particle beam imposes challenging requirements on a Wire Scanner system. It is expected to reach a scanning speed of 20 m.s-1 with a position accuracy of the order of 1 μm. In addition a timing accuracy better than 1 millisecond is needed. The adopted solution consists of a fork holding a wire rotating by a maximum of 200°. Fork, rotor and angular position sensor are mounted on the same axis and located in a chamber connected to the beam vacuum. The requirements imply the design of a system with extremely low vibration, vacuum compatibility, radiation and temperature tolerance. The adopted solution consists of a rotary brushless synchronous motor with the permanent magnet rotor installed inside of the vacuum chamber and the stator installed outside. The accurate position sensor will be mounted on the rotary shaft inside of the vacuum chamber, has to resist a bake-out temperature of 200°C and ionizing radiation up to a dozen of kGy/year. A digital feedback controller allows maxi...

  14. Gaia science alerts and the observing facilities of the Serbian-Bulgarian mini-network telescopes

    Directory of Open Access Journals (Sweden)

    Damljanović G.

    2014-01-01

    Full Text Available The astrometric European Space Agency (ESA Gaia mission was launched in December 19, 2013. One of the tasks of the Gaia mission is production of an astrometric catalog of over one billion stars and more than 500000 extragalactic sources. The quasars (QSOs, as extragalactic sources and radio emitters, are active galactic nuclei objects (AGNs whose coordinates are well determined via Very Long Baseline Interferometry (VLBI technique and may reach sub-milliarcsecond accuracy. The QSOs are the defining sources of the quasi-inertial International Celestial Reference Frame (ICRF because of their core radio morphology, negligible proper motions (until sub-milliarcsecond per year, and apparent point-like nature. Compact AGNs, visible in optical domain, are useful for a direct link of the future Gaia optical reference frame with the most accurate radio one. Apart from the above mentioned activities, Gaia has other goals such as follow-up of transient objects. One of the most important Gaia's requirements for photometric alerts is a fast observation and reduction response, that is, submition of observations within 24 hours. For this reason we have developed a pipeline. In line with possibilities of our new telescope (D(cm/F(cm=60/600 at the Astronomical Station Vidojevica (ASV, of the Astronomical Observatory in Belgrade, we joined the Gaia-Follow-Up Network for Transients Objects (Gaia-FUN-TO for the photometric alerts. Moreover, in view of the cooperation with Bulgarian colleagues (in the frst place, SV, one of us (GD initiated a local mini-network of Serbian { Bulgarian telescopes useful for the Gaia-FUN-TO and other astronomical purposes. During the next year we expect a new 1.4 m telescope at ASV site. The speed of data processing (from observation to calibration server could be one day. Here, we present an overview of our activities in the Gaia-FUN-TO which includes establishing Serbian { Bulgarian mini-network (of five telescopes at three sites

  15. High-accuracy mass determination of unstable nuclei with a Penning trap mass spectrometer

    CERN Multimedia

    2002-01-01

    The mass of a nucleus is its most fundamental property. A systematic study of nuclear masses as a function of neutron and proton number allows the observation of collective and single-particle effects in nuclear structure. Accurate mass data are the most basic test of nuclear models and are essential for their improvement. This is especially important for the astrophysical study of nuclear synthesis. In order to achieve the required high accuracy, the mass of ions captured in a Penning trap is determined via their cyclotron frequency $ \

  16. Techniques for Accurate Parallax Measurements for 6.7 GHz Methanol Masers

    Energy Technology Data Exchange (ETDEWEB)

    Reid, M. J. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Brunthaler, A.; Menten, K. M.; Sanna, A. [Max-Planck-Institut für Radioastronomy, Auf dem Hügel 69, D-53121-Bonn (Germany); Xu, Y.; Sakai, N. [Mizusawa VLBI Observatory, National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan); Li, J. J.; Wu, Y.; Hu, B. [Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing 210008 (China); Zheng, X. W. [Department of Astronomy, Nanjing University, Nanjing 210093 (China); Zhang, B. [Shanghai Astrophysical Observatory, 80 Nandan Road, Shanghai 200030 (China); Immer, K. [European Southern Observatory, Karl-Schwarzschild-Strasse 2, D-85748, Garching bei München (Germany); Rygl, K. [Italian ALMA Regional Centre, INAF—Istituto di Radioastronomia, Via P. Gobetti 101, I-40129 Bologna (Italy); Moscadelli, L. [INAF-Osservatorio Astrofisico di Arcetri, Largo E. Fermi 5, I-50125, Firenze (Italy); Bartkiewicz, A. [Centre for Astronomy, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Grudziadzka 5, 87-100 Torun (Poland); Choi, Y. K. [Korea Astronomy and Space Science Institute 776, Daedeokdae-ro, Yuseong-gu, Daejeon, 34055 (Korea, Republic of)

    2017-08-01

    The BeSSeL Survey is mapping the spiral structure of the Milky Way by measuring trigonometric parallaxes of hundreds of maser sources associated with high-mass star formation. While parallax techniques for water masers at high frequency (22 GHz) have been well documented, recent observations of methanol masers at lower frequency (6.7 GHz) have revealed astrometric issues associated with signal propagation through the ionosphere that could significantly limit parallax accuracy. These problems displayed as a “parallax gradient” on the sky when measured against different background quasars. We present an analysis method in which we generate position data relative to an “artificial quasar” at the target maser position at each epoch. Fitting parallax to these data can significantly mitigate the problems and improve parallax accuracy.

  17. The accuracy of prehospital diagnosis of acute cerebrovascular accidents: an observational study.

    Science.gov (United States)

    Karliński, Michał; Gluszkiewicz, Marcin; Członkowska, Anna

    2015-06-19

    Time to treatment is the key factor in stroke care. Although the initial medical assessment is usually made by a non-neurologist or a paramedic, it should ensure correct identification of all acute cerebrovascular accidents (CVAs). Our aim was to evaluate the accuracy of the physician-made prehospital diagnosis of acute CVA in patients referred directly to the neurological emergency department (ED), and to identify conditions mimicking CVAs. This observational study included consecutive patients referred to our neurological ED by emergency physicians with a suspicion of CVA (acute stroke, transient ischemic attack (TIA) or a syndrome-based diagnosis) during 12 months. Referrals were considered correct if the prehospital diagnosis of CVA proved to be stroke or TIA. The prehospital diagnosis of CVA was correct in 360 of 570 cases. Its positive predictive value ranged from 100% for the syndrome-based diagnosis, through 70% for stroke, to 34% for TIA. Misdiagnoses were less frequent among ambulance physicians compared to primary care and outpatient physicians (33% vs. 52%, p < 0.001). The most frequent mimics were vertigo (19%), electrolyte and metabolic disturbances (12%), seizures (11%), cardiovascular disorders (10%), blood hypertension (8%) and brain tumors (5%). Additionally, 6% of all admitted CVA cases were referred with prehospital diagnoses other than CVA. Emergency physicians appear to be sensitive in diagnosing CVAs but their overall accuracy does not seem high. They tend to overuse the diagnosis of TIA. Constant education and adoption of stroke screening scales may be beneficial for emergency care systems based both on physicians and on paramedics.

  18. Accuracy assessment of NOAA gridded daily reference evapotranspiration for the Texas High Plains

    Science.gov (United States)

    Moorhead, Jerry; Gowda, Prasanna H.; Hobbins, Michael; Senay, Gabriel; Paul, George; Marek, Thomas; Porter, Dana

    2015-01-01

    The National Oceanic and Atmospheric Administration (NOAA) provides daily reference evapotranspiration (ETref) maps for the contiguous United States using climatic data from North American Land Data Assimilation System (NLDAS). This data provides large-scale spatial representation of ETref, which is essential for regional scale water resources management. Data used in the development of NOAA daily ETref maps are derived from observations over surfaces that are different from short (grass — ETos) or tall (alfalfa — ETrs) reference crops, often in nonagricultural settings, which carries an unknown discrepancy between assumed and actual conditions. In this study, NOAA daily ETos and ETrs maps were evaluated for accuracy, using observed data from the Texas High Plains Evapotranspiration (TXHPET) network. Daily ETos, ETrs and the climatic data (air temperature, wind speed, and solar radiation) used for calculating ETref were extracted from the NOAA maps for TXHPET locations and compared against ground measurements on reference grass surfaces. NOAA ETrefmaps generally overestimated the TXHPET observations (1.4 and 2.2 mm/day ETos and ETrs, respectively), which may be attributed to errors in the NLDAS modeled air temperature and wind speed, to which reference ETref is most sensitive. Therefore, a bias correction to NLDAS modeled air temperature and wind speed data, or adjustment to the resulting NOAA ETref, may be needed to improve the accuracy of NOAA ETref maps.

  19. High-accuracy measurements of the normal specular reflectance

    International Nuclear Information System (INIS)

    Voarino, Philippe; Piombini, Herve; Sabary, Frederic; Marteau, Daniel; Dubard, Jimmy; Hameury, Jacques; Filtz, Jean Remy

    2008-01-01

    The French Laser Megajoule (LMJ) is designed and constructed by the French Commissariata l'Energie Atomique (CEA). Its amplifying section needs highly reflective multilayer mirrors for the flash lamps. To monitor and improve the coating process, the reflectors have to be characterized to high accuracy. The described spectrophotometer is designed to measure normal specular reflectance with high repeatability by using a small spot size of 100 μm. Results are compared with ellipsometric measurements. The instrument can also perform spatial characterization to detect coating nonuniformity

  20. Automation, Operation, and Data Analysis in the Cryogenic, High Accuracy, Refraction Measuring System (CHARMS)

    Science.gov (United States)

    Frey, Bradley J.; Leviton, Douglas B.

    2005-01-01

    The Cryogenic High Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center has been enhanced in a number of ways in the last year to allow the system to accurately collect refracted beam deviation readings automatically over a range of temperatures from 15 K to well beyond room temperature with high sampling density in both wavelength and temperature. The engineering details which make this possible are presented. The methods by which the most accurate angular measurements are made and the corresponding data reduction methods used to reduce thousands of observed angles to a handful of refractive index values are also discussed.

  1. A New Three-Dimensional High-Accuracy Automatic Alignment System For Single-Mode Fibers

    Science.gov (United States)

    Yun-jiang, Rao; Shang-lian, Huang; Ping, Li; Yu-mei, Wen; Jun, Tang

    1990-02-01

    In order to achieve the low-loss splices of single-mode fibers, a new three-dimension high-accuracy automatic alignment system for single -mode fibers has been developed, which includes a new-type three-dimension high-resolution microdisplacement servo stage driven by piezoelectric elements, a new high-accuracy measurement system for the misalignment error of the fiber core-axis, and a special single chip microcomputer processing system. The experimental results show that alignment accuracy of ±0.1 pin with a movable stroke of -±20μm has been obtained. This new system has more advantages than that reported.

  2. Gaia’s Cepheids and RR Lyrae stars and luminosity calibrations based on Tycho-Gaia Astrometric Solution

    Directory of Open Access Journals (Sweden)

    Clementini Gisella

    2017-01-01

    Full Text Available Gaia Data Release 1 contains parallaxes for more than 700 Galactic Cepheids and RR Lyrae stars, computed as part of the Tycho-Gaia Astrometric Solution (TGAS. We have used TGAS parallaxes, along with literature (V, I, J, Ks, W1 photometry and spectroscopy, to calibrate the zero point of the period-luminosity and period-Wesenheit relations of classical and type II Cepheids, and the near-infrared period-luminosity, period-luminosity-metallicity and optical luminosity-metallicity relations of RR Lyrae stars. In this contribution we briefly summarise results obtained by fitting these basic relations adopting different techniques that operate either in parallax or distance (absolute magnitude space.

  3. Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations.

    Science.gov (United States)

    Shokri, Abbas; Eskandarloo, Amir; Norouzi, Marouf; Poorolajal, Jalal; Majidi, Gelareh; Aliyaly, Alireza

    2018-03-01

    This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) scans obtained with 2 CBCT systems with high- and low-resolution modes for the detection of root perforations in endodontically treated mandibular molars. The root canals of 72 mandibular molars were cleaned and shaped. Perforations measuring 0.2, 0.3, and 0.4 mm in diameter were created at the furcation area of 48 roots, simulating strip perforations, or on the external surfaces of 48 roots, simulating root perforations. Forty-eight roots remained intact (control group). The roots were filled using gutta-percha (Gapadent, Tianjin, China) and AH26 sealer (Dentsply Maillefer, Ballaigues, Switzerland). The CBCT scans were obtained using the NewTom 3G (QR srl, Verona, Italy) and Cranex 3D (Soredex, Helsinki, Finland) CBCT systems in high- and low-resolution modes, and were evaluated by 2 observers. The chi-square test was used to assess the nominal variables. In strip perforations, the accuracies of low- and high-resolution modes were 75% and 83% for NewTom 3G and 67% and 69% for Cranex 3D. In root perforations, the accuracies of low- and high-resolution modes were 79% and 83% for NewTom 3G and was 56% and 73% for Cranex 3D. The accuracy of the 2 CBCT systems was different for the detection of strip and root perforations. The Cranex 3D had non-significantly higher accuracy than the NewTom 3G. In both scanners, the high-resolution mode yielded significantly higher accuracy than the low-resolution mode. The diagnostic accuracy of CBCT scans was not affected by the perforation diameter.

  4. Computer modeling of oil spill trajectories with a high accuracy method

    International Nuclear Information System (INIS)

    Garcia-Martinez, Reinaldo; Flores-Tovar, Henry

    1999-01-01

    This paper proposes a high accuracy numerical method to model oil spill trajectories using a particle-tracking algorithm. The Euler method, used to calculate oil trajectories, can give adequate solutions in most open ocean applications. However, this method may not predict accurate particle trajectories in certain highly non-uniform velocity fields near coastal zones or in river problems. Simple numerical experiments show that the Euler method may also introduce artificial numerical dispersion that could lead to overestimation of spill areas. This article proposes a fourth-order Runge-Kutta method with fourth-order velocity interpolation to calculate oil trajectories that minimise these problems. The algorithm is implemented in the OilTrack model to predict oil trajectories following the 'Nissos Amorgos' oil spill accident that occurred in the Gulf of Venezuela in 1997. Despite lack of adequate field information, model results compare well with observations in the impacted area. (Author)

  5. Astrometric observations of Saturn's satellites from McDonald Observatory, 1972

    Science.gov (United States)

    Abbot, R. I.; Mulholland, J. D.; Shelus, P. J.

    1975-01-01

    Observations of Saturn's satellites have been reduced by means of secondary reference stars obtained by reduction of Palomar Sky Survey plates. This involved the use of 29 SAO stars and plate overlap technique to determine the coordinates of 59 fainter stars in the satellite field. Fourteen plate constants were determined for each of the two PSS plates. Comparison of two plate measurement and reduction techniques on the satellite measures appears to demonstrate the existence of a serious background gradient effect and the utility of microdensitometry to eliminate this error source in positional determinations of close satellites.

  6. Adaptive sensor-based ultra-high accuracy solar concentrator tracker

    Science.gov (United States)

    Brinkley, Jordyn; Hassanzadeh, Ali

    2017-09-01

    Conventional solar trackers use information of the sun's position, either by direct sensing or by GPS. Our method uses the shading of the receiver. This, coupled with nonimaging optics design allows us to achieve ultra-high concentration. Incorporating a sensor based shadow tracking method with a two stage concentration solar hybrid parabolic trough allows the system to maintain high concentration with acute accuracy.

  7. High accuracy digital aging monitor based on PLL-VCO circuit

    International Nuclear Information System (INIS)

    Zhang Yuejun; Jiang Zhidi; Wang Pengjun; Zhang Xuelong

    2015-01-01

    As the manufacturing process is scaled down to the nanoscale, the aging phenomenon significantly affects the reliability and lifetime of integrated circuits. Consequently, the precise measurement of digital CMOS aging is a key aspect of nanoscale aging tolerant circuit design. This paper proposes a high accuracy digital aging monitor using phase-locked loop and voltage-controlled oscillator (PLL-VCO) circuit. The proposed monitor eliminates the circuit self-aging effect for the characteristic of PLL, whose frequency has no relationship with circuit aging phenomenon. The PLL-VCO monitor is implemented in TSMC low power 65 nm CMOS technology, and its area occupies 303.28 × 298.94 μm 2 . After accelerating aging tests, the experimental results show that PLL-VCO monitor improves accuracy about high temperature by 2.4% and high voltage by 18.7%. (semiconductor integrated circuits)

  8. First results of astrometric and photometric processing of scanned plates DLFA MAO NAS of Ukraine

    Science.gov (United States)

    Shatokhina, S.; Andruk, V.; Yatsenko, A.

    2011-02-01

    In the paper the first estimation of astrometric and photometric results of digitization of images on plates of Double Long Focus Astrograph (DLFA) was made. The digitization of plates was carried out with the scanner Microtek ScanMaker 9800XL TMA. For image processing the package LINUX/MIDAS/ROMAFOT was used. For selected plates DLFA mean square errors for equatorial coordinates (in a system of TYCHO-2 catalogue) and stellar magnitudes (in the Johnson B-system) per one image are 0.06" and 0.13m. The errors are of random nature and there are no systematic dependences on coordinates, magnitudes and colour of stars. The comparison of obtained results with that of earlier plate measurements obtained with complex PARSEC was made.

  9. Achieving Climate Change Absolute Accuracy in Orbit

    Science.gov (United States)

    Wielicki, Bruce A.; Young, D. F.; Mlynczak, M. G.; Thome, K. J; Leroy, S.; Corliss, J.; Anderson, J. G.; Ao, C. O.; Bantges, R.; Best, F.; hide

    2013-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

  10. High current high accuracy IGBT pulse generator

    International Nuclear Information System (INIS)

    Nesterov, V.V.; Donaldson, A.R.

    1995-05-01

    A solid state pulse generator capable of delivering high current triangular or trapezoidal pulses into an inductive load has been developed at SLAC. Energy stored in a capacitor bank of the pulse generator is switched to the load through a pair of insulated gate bipolar transistors (IGBT). The circuit can then recover the remaining energy and transfer it back to the capacitor bank without reversing the capacitor voltage. A third IGBT device is employed to control the initial charge to the capacitor bank, a command charging technique, and to compensate for pulse to pulse power losses. The rack mounted pulse generator contains a 525 μF capacitor bank. It can deliver 500 A at 900V into inductive loads up to 3 mH. The current amplitude and discharge time are controlled to 0.02% accuracy by a precision controller through the SLAC central computer system. This pulse generator drives a series pair of extraction dipoles

  11. Lunar occultation of Saturn. IV - Astrometric results from observations of the satellites

    Science.gov (United States)

    Dunham, D. W.; Elliot, J. L.

    1978-01-01

    The method of determining local lunar limb slopes, and the consequent time scale needed for diameter studies, from accurate occultation timings at two nearby telescopes is described. Results for photoelectric observations made at Mauna Kea Observatory during the occultation of Saturn's satellites on March 30, 1974, are discussed. Analysis of all observations of occultations of Saturn's satellites during 1974 indicates possible errors in the ephemerides of Saturn and its satellites.

  12. High-accuracy determination for optical indicatrix rotation in ferroelectric DTGS

    OpenAIRE

    O.S.Kushnir; O.A.Bevz; O.G.Vlokh

    2000-01-01

    Optical indicatrix rotation in deuterated ferroelectric triglycine sulphate is studied with the high-accuracy null-polarimetric technique. The behaviour of the effect in ferroelectric phase is referred to quadratic spontaneous electrooptics.

  13. Achieving High Accuracy in Calculations of NMR Parameters

    DEFF Research Database (Denmark)

    Faber, Rasmus

    quantum chemical methods have been developed, the calculation of NMR parameters with quantitative accuracy is far from trivial. In this thesis I address some of the issues that makes accurate calculation of NMR parameters so challenging, with the main focus on SSCCs. High accuracy quantum chemical......, but no programs were available to perform such calculations. As part of this thesis the CFOUR program has therefore been extended to allow the calculation of SSCCs using the CC3 method. CC3 calculations of SSCCs have then been performed for several molecules, including some difficult cases. These results show...... vibrations must be included. The calculation of vibrational corrections to NMR parameters has been reviewed as part of this thesis. A study of the basis set convergence of vibrational corrections to nuclear shielding constants has also been performed. The basis set error in vibrational correction...

  14. Absolute Nuv magnitudes of Gaia DR1 astrometric stars and a search for hot companions in nearby systems

    Science.gov (United States)

    Makarov, V. V.

    2017-10-01

    Accurate parallaxes from Gaia DR1 (TGAS) are combined with GALEX visual Nuv magnitudes to produce absolute Mnuv magnitudes and an ultraviolet HR diagram for a large sample of astrometric stars. A functional fit is derived of the lower envelope main sequence of the nearest 1403 stars (distance Pleiades, or, most likely, tight interacting binaries of the BY Dra-type. A separate collection of 40 stars with precise trigonometric parallaxes and Nuv-G colors bluer than 2 mag is presented. It includes several known novae, white dwarfs, and binaries with hot subdwarf (sdOB) components, but most remain unexplored.

  15. High Accuracy Piezoelectric Kinemometer; Cinemometro piezoelectrico de alta exactitud (VUAE)

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez Martinez, F. J.; Frutos, J. de; Pastor, C.; Vazquez Rodriguez, M.

    2012-07-01

    We have developed a portable computerized and low consumption, our system is called High Accuracy Piezoelectric Kinemometer measurement, herein VUAE. By the high accuracy obtained by VUAE it make able to use the VUAE to obtain references measurements of system for measuring Speeds in Vehicles. Therefore VUAE could be used how reference equipment to estimate the error of installed kinemometers. The VUAE was created with n (n=2) pairs of ultrasonic transmitter-receiver, herein E-Rult. The transmitters used in the n couples E-Rult generate n ultrasonic barriers and receivers receive the echoes when the vehicle crosses the barriers. Digital processing of the echoes signals let us to obtain acceptable signals. Later, by mean of cross correlation technics is possible make a highly exact estimation of speed of the vehicle. The log of the moments of interception and the distance between each of the n ultrasounds allows for a highly exact estimation of speed of the vehicle. VUAE speed measurements were compared to a speed reference system based on piezoelectric cables. (Author) 11 refs.

  16. Diagnostic accuracy of fracture detection in suspected non-accidental injury: the effect of edge enhancement and digital display on observer performance

    Energy Technology Data Exchange (ETDEWEB)

    Offiah, A.C. [Department of Radiology, Great Ormond Street Hospital for Children, London (United Kingdom) and Institute of Child Health, London (United Kingdom)]. E-mail: amaka.offiah@gosh.nhs.uk; Moon, L. [Department of Radiology, Great Ormond Street Hospital for Children, London (United Kingdom); Hall, C.M. [Department of Radiology, Great Ormond Street Hospital for Children, London (United Kingdom); Todd-Pokropek, A. [Department of Medical Physics and Bioengineering, University College London, London (United Kingdom)

    2006-02-15

    AIM: To compare the effect of varying degrees of edge enhancement and method of digital image display on fracture detection in suspected non-accidental injury (NAI). MATERIALS AND METHODS: Fifty radiographs from post-mortem skeletal surveys in 13 children with suspected NAI were selected. Images were obtained using a Fuji 5000R computed radiography system. Hard copies were printed with edge enhancement factors 0, 0.5 and 1.2. Images (edge enhancement 0.5) were also displayed on a 1K{sup 2} monitor. Six observers independently evaluated all 200 images for the presence of abnormality. Observers also scored each image for visualization of soft tissues, visualization of trabecular markings and overall image quality. The paired Student's t-test and location receiver operating curve (ROC) analysis were used to compare quality scores and diagnostic accuracy of each display method. Individual and pooled true-positive rates (sensitivity) were determined. For the purposes of ROC analysis, histology was taken as the gold standard. RESULTS: There was no difference in duration of hard and soft-copy reading sessions (p=0.76). After image manipulation soft-copy radiographs scored significantly better for image quality than hard copy (p<0.0001). Pooled observer sensitivity (at a specificity of 90%) was below 50% for all display methods. Diagnostic accuracy varied significantly between observers. Diagnostic accuracy of individual observers was not affected by display method. CONCLUSION: In suspected NAI, diagnostic accuracy of fracture detection is generally low. Diagnostic accuracy appears to be affected more by observer-related factors than by the method of digital image display.

  17. The AUSTRAL VLBI observing program

    Science.gov (United States)

    Plank, L.; Lovell, J. E. J.; McCallum, J. N.; Mayer, D.; Reynolds, C.; Quick, J.; Weston, S.; Titov, O.; Shabala, S. S.; Böhm, J.; Natusch, T.; Nickola, M.; Gulyaev, S.

    2017-07-01

    The AUSTRAL observing program was started in 2011, performing geodetic and astrometric very long baseline interferometry (VLBI) sessions using the new Australian AuScope VLBI antennas at Hobart, Katherine, and Yarragadee, with contribution from the Warkworth (New Zealand) 12 m and Hartebeesthoek (South Africa) 15 m antennas to make a southern hemisphere array of telescopes with similar design and capability. Designed in the style of the next-generation VLBI system, these small and fast antennas allow for a new way of observing, comprising higher data rates and more observations than the standard observing sessions coordinated by the International VLBI Service for Geodesy and Astrometry (IVS). In this contribution, the continuous development of the AUSTRAL sessions is described, leading to an improvement of the results in terms of baseline length repeatabilities by a factor of two since the start of this program. The focus is on the scheduling strategy and increased number of observations, aspects of automated operation, and data logistics, as well as results of the 151 AUSTRAL sessions performed so far. The high number of the AUSTRAL sessions makes them an important contributor to VLBI end-products, such as the terrestrial and celestial reference frames and Earth orientation parameters. We compare AUSTRAL results with other IVS sessions and discuss their suitability for the determination of baselines, station coordinates, source coordinates, and Earth orientation parameters.

  18. TMAP: A NEO follow-up program utilizing undergraduate observers

    Science.gov (United States)

    Ramirez, C.; Deaver, D.; Martinez, R.; Foster, J.; Kuang, L.; Ates, A.; Anderson, M.; Mijac, M.; Gillam, S.; Hicks, M. D.

    2000-10-01

    In the spring of 2000 we began TMAP (Table Mountain Astrometry Project), a program designed to provide timely astrometric followup of newly discovered near-Earth asteroids. Relying on undergraduate observers from the local California State Universities, we have to date been involved with the over 50 NEO and new comet discoveries. This is a significant fraction of all near-Earth asteroids discovered over the time period. All observations are performed at JPL's Table Mountain Facility near Wrightwood California using the 0.6-meter telescope equipped with a Photometrics LN cooled 1k CCD mounted at the cassegrain focus. With this system we can routinely detect objects to R=20.5. We have typically scheduled two runs per month on weekends bracketing the new moon. The student observers man the telescope are trained to select and obtain R-band images of candidates from the Minor Planet Center's NEO Confirmation Page (http://cfa-www.harvard.edu/cfa/ps/NEO/TheNEOPage.html). The astrometry is then reduced and submitted to the Minor Planet Center the following day. TMAP has proven to be an efficient way both to obtain much needed astrometric measurements of newly discovered small bodies as well as to involve undergraduate researchers in planetary research. The limiting magnitudes provided by the 0.6-meter partially fills the gap between the extremely helpful and dedicated amateur astromitrists and the followup that the NEO detection programs do themselves. This work is supported by NASA.

  19. Accuracy of self-reported drinking: observational verification of 'last occasion' drink estimates of young adults.

    Science.gov (United States)

    Northcote, Jeremy; Livingston, Michael

    2011-01-01

    As a formative step towards determining the accuracy of self-reported drinking levels commonly used for estimating population alcohol use, the validity of a 'last occasion' self-reporting approach is tested with corresponding field observations of participants' drinking quantity. This study is the first known attempt to validate the accuracy of self-reported alcohol consumption using data from a natural setting. A total of 81 young adults (aged 18-25 years) were purposively selected in Perth, Western Australia. Participants were asked to report the number of alcoholic drinks consumed at nightlife venues 1-2 days after being observed by peer-based researchers on 239 occasions. Complete observation data and self-report estimates were available for 129 sessions, which were fitted with multi-level models assessing the relationship between observed and reported consumption. Participants accurately estimated their consumption when engaging in light to moderate drinking (eight or fewer drinks in a single session), with no significant difference between the mean reported consumption and the mean observed consumption. In contrast, participants underestimated their own consumption by increasing amounts when engaging in heavy drinking of more than eight drinks. It is suggested that recent recall methods in self-report surveys are potentially reasonably accurate measures of actual drinking levels for light to moderate drinkers, but that underestimating of alcohol consumption increases with heavy consumption. Some of the possible reasons for underestimation of heavy drinking are discussed, with both cognitive and socio-cultural factors considered.

  20. Cadastral Database Positional Accuracy Improvement

    Science.gov (United States)

    Hashim, N. M.; Omar, A. H.; Ramli, S. N. M.; Omar, K. M.; Din, N.

    2017-10-01

    Positional Accuracy Improvement (PAI) is the refining process of the geometry feature in a geospatial dataset to improve its actual position. This actual position relates to the absolute position in specific coordinate system and the relation to the neighborhood features. With the growth of spatial based technology especially Geographical Information System (GIS) and Global Navigation Satellite System (GNSS), the PAI campaign is inevitable especially to the legacy cadastral database. Integration of legacy dataset and higher accuracy dataset like GNSS observation is a potential solution for improving the legacy dataset. However, by merely integrating both datasets will lead to a distortion of the relative geometry. The improved dataset should be further treated to minimize inherent errors and fitting to the new accurate dataset. The main focus of this study is to describe a method of angular based Least Square Adjustment (LSA) for PAI process of legacy dataset. The existing high accuracy dataset known as National Digital Cadastral Database (NDCDB) is then used as bench mark to validate the results. It was found that the propose technique is highly possible for positional accuracy improvement of legacy spatial datasets.

  1. Why is a high accuracy needed in dosimetry

    International Nuclear Information System (INIS)

    Lanzl, L.H.

    1976-01-01

    Dose and exposure intercomparisons on a national or international basis have become an important component of quality assurance in the practice of good radiotherapy. A high degree of accuracy of γ and x radiation dosimetry is essential in our international society, where medical information is so readily exchanged and used. The value of accurate dosimetry lies mainly in the avoidance of complications in normal tissue and an optimal degree of tumor control

  2. Light propagation in the gravitational field of N arbitrarily moving bodies in the 1.5PN approximation for high-precision astrometry

    Science.gov (United States)

    Zschocke, Sven

    2016-05-01

    High-precision astrometry on sub-micro-arcsecond level in angular resolution requires accurate determination of the trajectory of a light-signal from the celestial light source through the gravitational field of the Solar System toward the observer. In this investigation the light trajectory in the gravitational field of N moving bodies is determined in the 1.5 post-Newtonian approximation. In the approach presented two specific issues of particular importance are accounted for: (1) According to the recommendations of International Astronomical Union, the metric of the Solar System is expressed in terms of intrinsic mass-multipoles and intrinsic spin-multipoles of the massive bodies, allowing for arbitrary shape, inner structure and rotational motion of the massive bodies of the Solar System. (2) The Solar System bodies move along arbitrary world lines which can later be specified by Solar System ephemeris. The presented analytical solution for light trajectory is a primary requirement for extremely high-precision astrometry on sub-micro-arcsecond level of accuracy and associated massive computations in astrometric data reduction. An estimation of the numerical magnitude for time delay and light deflection of the leading multipoles is given.

  3. Innovative Fiber-Optic Gyroscopes (FOGs) for High Accuracy Space Applications, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This project aims to develop a compact, highly innovative Inertial Reference/Measurement Unit (IRU/IMU) that pushes the state-of-the-art in high accuracy performance...

  4. High accuracy acoustic relative humidity measurement in duct flow with air.

    Science.gov (United States)

    van Schaik, Wilhelm; Grooten, Mart; Wernaart, Twan; van der Geld, Cees

    2010-01-01

    An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0-12 m/s with an error of ± 0.13 m/s, temperature 0-100 °C with an error of ± 0.07 °C and relative humidity 0-100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments.

  5. Towards high resolution mapping of 3-D mesoscale dynamics from observations

    Directory of Open Access Journals (Sweden)

    B. Buongiorno Nardelli

    2012-10-01

    Full Text Available The MyOcean R&D project MESCLA (MEsoSCaLe dynamical Analysis through combined model, satellite and in situ data was devoted to the high resolution 3-D retrieval of tracer and velocity fields in the oceans, based on the combination of in situ and satellite observations and quasi-geostrophic dynamical models. The retrieval techniques were also tested and compared with the output of a primitive equation model, with particular attention to the accuracy of the vertical velocity field as estimated through the Q vector formulation of the omega equation. The project focused on a test case, covering the region where the Gulf Stream separates from the US East Coast. This work demonstrated that innovative methods for the high resolution mapping of 3-D mesoscale dynamics from observations can be used to build the next generations of operational observation-based products.

  6. Two high accuracy digital integrators for Rogowski current transducers

    Science.gov (United States)

    Luo, Pan-dian; Li, Hong-bin; Li, Zhen-hua

    2014-01-01

    The Rogowski current transducers have been widely used in AC current measurement, but their accuracy is mainly subject to the analog integrators, which have typical problems such as poor long-term stability and being susceptible to environmental conditions. The digital integrators can be another choice, but they cannot obtain a stable and accurate output for the reason that the DC component in original signal can be accumulated, which will lead to output DC drift. Unknown initial conditions can also result in integral output DC offset. This paper proposes two improved digital integrators used in Rogowski current transducers instead of traditional analog integrators for high measuring accuracy. A proportional-integral-derivative (PID) feedback controller and an attenuation coefficient have been applied in improving the Al-Alaoui integrator to change its DC response and get an ideal frequency response. For the special design in the field of digital signal processing, the improved digital integrators have better performance than analog integrators. Simulation models are built for the purpose of verification and comparison. The experiments prove that the designed integrators can achieve higher accuracy than analog integrators in steady-state response, transient-state response, and temperature changing condition.

  7. Electron ray tracing with high accuracy

    International Nuclear Information System (INIS)

    Saito, K.; Okubo, T.; Takamoto, K.; Uno, Y.; Kondo, M.

    1986-01-01

    An electron ray tracing program is developed to investigate the overall geometrical and chromatic aberrations in electron optical systems. The program also computes aberrations due to manufacturing errors in lenses and deflectors. Computation accuracy is improved by (1) calculating electrostatic and magnetic scalar potentials using the finite element method with third-order isoparametric elements, and (2) solving the modified ray equation which the aberrations satisfy. Computation accuracy of 4 nm is achieved for calculating optical properties of the system with an electrostatic lens

  8. High accuracy 3D electromagnetic finite element analysis

    International Nuclear Information System (INIS)

    Nelson, Eric M.

    1997-01-01

    A high accuracy 3D electromagnetic finite element field solver employing quadratic hexahedral elements and quadratic mixed-order one-form basis functions will be described. The solver is based on an object-oriented C++ class library. Test cases demonstrate that frequency errors less than 10 ppm can be achieved using modest workstations, and that the solutions have no contamination from spurious modes. The role of differential geometry and geometrical physics in finite element analysis will also be discussed

  9. High accuracy 3D electromagnetic finite element analysis

    International Nuclear Information System (INIS)

    Nelson, E.M.

    1996-01-01

    A high accuracy 3D electromagnetic finite element field solver employing quadratic hexahedral elements and quadratic mixed-order one-form basis functions will be described. The solver is based on an object-oriented C++ class library. Test cases demonstrate that frequency errors less than 10 ppm can be achieved using modest workstations, and that the solutions have no contamination from spurious modes. The role of differential geometry and geometrical physics in finite element analysis will also be discussed

  10. A High-Throughput, High-Accuracy System-Level Simulation Framework for System on Chips

    Directory of Open Access Journals (Sweden)

    Guanyi Sun

    2011-01-01

    Full Text Available Today's System-on-Chips (SoCs design is extremely challenging because it involves complicated design tradeoffs and heterogeneous design expertise. To explore the large solution space, system architects have to rely on system-level simulators to identify an optimized SoC architecture. In this paper, we propose a system-level simulation framework, System Performance Simulation Implementation Mechanism, or SPSIM. Based on SystemC TLM2.0, the framework consists of an executable SoC model, a simulation tool chain, and a modeling methodology. Compared with the large body of existing research in this area, this work is aimed at delivering a high simulation throughput and, at the same time, guaranteeing a high accuracy on real industrial applications. Integrating the leading TLM techniques, our simulator can attain a simulation speed that is not slower than that of the hardware execution by a factor of 35 on a set of real-world applications. SPSIM incorporates effective timing models, which can achieve a high accuracy after hardware-based calibration. Experimental results on a set of mobile applications proved that the difference between the simulated and measured results of timing performance is within 10%, which in the past can only be attained by cycle-accurate models.

  11. High Accuracy Acoustic Relative Humidity Measurement inDuct Flow with Air

    Directory of Open Access Journals (Sweden)

    Cees van der Geld

    2010-08-01

    Full Text Available An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0–12 m/s with an error of ±0.13 m/s, temperature 0–100 °C with an error of ±0.07 °C and relative humidity 0–100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments.

  12. StreakDet data processing and analysis pipeline for space debris optical observations

    Science.gov (United States)

    Virtanen, Jenni; Flohrer, Tim; Muinonen, Karri; Granvik, Mikael; Torppa, Johanna; Poikonen, Jonne; Lehti, Jussi; Santti, Tero; Komulainen, Tuomo; Naranen, Jyri

    We describe a novel data processing and analysis pipeline for optical observations of space debris. The monitoring of space object populations requires reliable acquisition of observational data, to support the development and validation of space debris environment models, the build-up and maintenance of a catalogue of orbital elements. In addition, data is needed for the assessment of conjunction events and for the support of contingency situations or launches. The currently available, mature image processing algorithms for detection and astrometric reduction of optical data cover objects that cross the sensor field-of-view comparably slowly, and within a rather narrow, predefined range of angular velocities. By applying specific tracking techniques, the objects appear point-like or as short trails in the exposures. However, the general survey scenario is always a “track before detect” problem, resulting in streaks, i.e., object trails of arbitrary lengths, in the images. The scope of the ESA-funded StreakDet (Streak detection and astrometric reduction) project is to investigate solutions for detecting and reducing streaks from optical images, particularly in the low signal-to-noise ratio (SNR) domain, where algorithms are not readily available yet. For long streaks, the challenge is to extract precise position information and related registered epochs with sufficient precision. Although some considerations for low-SNR processing of streak-like features are available in the current image processing and computer vision literature, there is a need to discuss and compare these approaches for space debris analysis, in order to develop and evaluate prototype implementations. In the StreakDet project, we develop algorithms applicable to single images (as compared to consecutive frames of the same field) obtained with any observing scenario, including space-based surveys and both low- and high-altitude populations. The proposed processing pipeline starts from the

  13. Accuracy of inference on the physics of binary evolution from gravitational-wave observations

    Science.gov (United States)

    Barrett, Jim W.; Gaebel, Sebastian M.; Neijssel, Coenraad J.; Vigna-Gómez, Alejandro; Stevenson, Simon; Berry, Christopher P. L.; Farr, Will M.; Mandel, Ilya

    2018-04-01

    The properties of the population of merging binary black holes encode some of the uncertain physics underlying the evolution of massive stars in binaries. The binary black hole merger rate and chirp-mass distribution are being measured by ground-based gravitational-wave detectors. We consider isolated binary evolution, and explore how accurately the physical model can be constrained with such observations by applying the Fisher information matrix to the merging black hole population simulated with the rapid binary-population synthesis code COMPAS. We investigate variations in four COMPAS parameters: common-envelope efficiency, kick-velocity dispersion, and mass-loss rates during the luminous blue variable and Wolf-Rayet stellar-evolutionary phases. We find that ˜1000 observations would constrain these model parameters to a fractional accuracy of a few per cent. Given the empirically determined binary black hole merger rate, we can expect gravitational-wave observations alone to place strong constraints on the physics of stellar and binary evolution within a few years. Our approach can be extended to use other observational data sets; combining observations at different evolutionary stages will lead to a better understanding of stellar and binary physics.

  14. High accuracy 3D electromagnetic finite element analysis

    International Nuclear Information System (INIS)

    Nelson, E.M.

    1997-01-01

    A high accuracy 3D electromagnetic finite element field solver employing quadratic hexahedral elements and quadratic mixed-order one-form basis functions will be described. The solver is based on an object-oriented C++ class library. Test cases demonstrate that frequency errors less than 10 ppm can be achieved using modest workstations, and that the solutions have no contamination from spurious modes. The role of differential geometry and geometrical physics in finite element analysis will also be discussed. copyright 1997 American Institute of Physics

  15. An observational study of the accuracy and completeness of an anesthesia information management system: recommendations for documentation system changes.

    Science.gov (United States)

    Wilbanks, Bryan A; Moss, Jacqueline A; Berner, Eta S

    2013-08-01

    Anesthesia information management systems must often be tailored to fit the environment in which they are implemented. Extensive customization necessitates that systems be analyzed for both accuracy and completeness of documentation design to ensure that the final record is a true representation of practice. The purpose of this study was to determine the accuracy of a recently installed system in the capture of key perianesthesia data. This study used an observational design and was conducted using a convenience sample of nurse anesthetists. Observational data of the nurse anesthetists'delivery of anesthesia care were collected using a touch-screen tablet computer utilizing an Access database customized observational data collection tool. A questionnaire was also administered to these nurse anesthetists to assess perceived accuracy, completeness, and satisfaction with the electronic documentation system. The major sources of data not documented in the system were anesthesiologist presence (20%) and placement of intravenous lines (20%). The major sources of inaccuracies in documentation were gas flow rates (45%), medication administration times (30%), and documentation of neuromuscular function testing (20%)-all of the sources of inaccuracies were related to the use of charting templates that were not altered to reflect the actual interventions performed.

  16. The effect of pattern overlap on the accuracy of high resolution electron backscatter diffraction measurements

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Vivian, E-mail: v.tong13@imperial.ac.uk [Department of Materials, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom); Jiang, Jun [Department of Materials, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom); Wilkinson, Angus J. [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Britton, T. Ben [Department of Materials, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom)

    2015-08-15

    High resolution, cross-correlation-based, electron backscatter diffraction (EBSD) measures the variation of elastic strains and lattice rotations from a reference state. Regions near grain boundaries are often of interest but overlap of patterns from the two grains could reduce accuracy of the cross-correlation analysis. To explore this concern, patterns from the interior of two grains have been mixed to simulate the interaction volume crossing a grain boundary so that the effect on the accuracy of the cross correlation results can be tested. It was found that the accuracy of HR-EBSD strain measurements performed in a FEG-SEM on zirconium remains good until the incident beam is less than 18 nm from a grain boundary. A simulated microstructure was used to measure how often pattern overlap occurs at any given EBSD step size, and a simple relation was found linking the probability of overlap with step size. - Highlights: • Pattern overlap occurs at grain boundaries and reduces HR-EBSD accuracy. • A test is devised to measure the accuracy of HR-EBSD in the presence of overlap. • High pass filters can sometimes, but not generally, improve HR-EBSD measurements. • Accuracy of HR-EBSD remains high until the reference pattern intensity is <72%. • 9% of points near a grain boundary will have significant error for 200nm step size in Zircaloy-4.

  17. Read-only high accuracy volume holographic optical correlator

    Science.gov (United States)

    Zhao, Tian; Li, Jingming; Cao, Liangcai; He, Qingsheng; Jin, Guofan

    2011-10-01

    A read-only volume holographic correlator (VHC) is proposed. After the recording of all of the correlation database pages by angular multiplexing, a stand-alone read-only high accuracy VHC will be separated from the VHC recording facilities which include the high-power laser and the angular multiplexing system. The stand-alone VHC has its own low power readout laser and very compact and simple structure. Since there are two lasers that are employed for recording and readout, respectively, the optical alignment tolerance of the laser illumination on the SLM is very sensitive. The twodimensional angular tolerance is analyzed based on the theoretical model of the volume holographic correlator. The experimental demonstration of the proposed read-only VHC is introduced and discussed.

  18. Revisiting TW Hydrae in light of new astrometric data

    Science.gov (United States)

    Teixeira, R.; Ducourant, C.; Galli, P. A. B.; Le Campion, J. F.; Zuckerman, B.; Krone-Martins, A. G. O.; Chauvin, G.; Song, I.

    2014-10-01

    Our efforts in the present work focused mainly on refining and improving the previous description and understanding of the stellar association TW Hydrae (TWA) including a very detailed membership analysis and its dynamical and evolutionary age.To achieve our objectives in a fully reliable way we take advantage of our own astrometric measurements (Ducourant et al. 2013) performed with NTT/EFOSC2 - ESO (La Silla - Chile) spread over three years (2007 - 2010) and of those published in the literature.A very detailed membership analysis based on the convergent point strategy as developed by our team (Galli et al. 2012, 2013) allowed us to define a consistent kinematic group containing 31 stars among the 44 proposed as TWA member in the literature. Assuming that our sample of stars may be contaminated by non-members and to get rid of the particular influence of each star we applied a Jacknife resampling technique generating 2000 random lists of 13 stars taken from our 16 stars and calculated for each the epoch of convergence when the radius is minimum. The mean of the epochs obtained and the dispersion about the mean give a dynamical age of 7.5± 0.7 Myr for the association that is in good agreement with the previous traceback age (De La Reza et al. 2006). We also estimated age for TWA moving group members from pre-main sequence evolutionary models (Siess et al. 2000) and find a mean age of 7.4± 1.2 Myr. These results show that the dynamical age of the association obtained via the traceback technique and the average age derived from theoretical evolutionary models are in good agreement.

  19. Optical System Error Analysis and Calibration Method of High-Accuracy Star Trackers

    Directory of Open Access Journals (Sweden)

    Zheng You

    2013-04-01

    Full Text Available The star tracker is a high-accuracy attitude measurement device widely used in spacecraft. Its performance depends largely on the precision of the optical system parameters. Therefore, the analysis of the optical system parameter errors and a precise calibration model are crucial to the accuracy of the star tracker. Research in this field is relatively lacking a systematic and universal analysis up to now. This paper proposes in detail an approach for the synthetic error analysis of the star tracker, without the complicated theoretical derivation. This approach can determine the error propagation relationship of the star tracker, and can build intuitively and systematically an error model. The analysis results can be used as a foundation and a guide for the optical design, calibration, and compensation of the star tracker. A calibration experiment is designed and conducted. Excellent calibration results are achieved based on the calibration model. To summarize, the error analysis approach and the calibration method are proved to be adequate and precise, and could provide an important guarantee for the design, manufacture, and measurement of high-accuracy star trackers.

  20. Optical system error analysis and calibration method of high-accuracy star trackers.

    Science.gov (United States)

    Sun, Ting; Xing, Fei; You, Zheng

    2013-04-08

    The star tracker is a high-accuracy attitude measurement device widely used in spacecraft. Its performance depends largely on the precision of the optical system parameters. Therefore, the analysis of the optical system parameter errors and a precise calibration model are crucial to the accuracy of the star tracker. Research in this field is relatively lacking a systematic and universal analysis up to now. This paper proposes in detail an approach for the synthetic error analysis of the star tracker, without the complicated theoretical derivation. This approach can determine the error propagation relationship of the star tracker, and can build intuitively and systematically an error model. The analysis results can be used as a foundation and a guide for the optical design, calibration, and compensation of the star tracker. A calibration experiment is designed and conducted. Excellent calibration results are achieved based on the calibration model. To summarize, the error analysis approach and the calibration method are proved to be adequate and precise, and could provide an important guarantee for the design, manufacture, and measurement of high-accuracy star trackers.

  1. Innovative Fiber-Optic Gyroscopes (FOGs) for High Accuracy Space Applications, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's future science and exploratory missions will require much lighter, smaller, and longer life rate sensors that can provide high accuracy navigational...

  2. MUSCLE: multiple sequence alignment with high accuracy and high throughput.

    Science.gov (United States)

    Edgar, Robert C

    2004-01-01

    We describe MUSCLE, a new computer program for creating multiple alignments of protein sequences. Elements of the algorithm include fast distance estimation using kmer counting, progressive alignment using a new profile function we call the log-expectation score, and refinement using tree-dependent restricted partitioning. The speed and accuracy of MUSCLE are compared with T-Coffee, MAFFT and CLUSTALW on four test sets of reference alignments: BAliBASE, SABmark, SMART and a new benchmark, PREFAB. MUSCLE achieves the highest, or joint highest, rank in accuracy on each of these sets. Without refinement, MUSCLE achieves average accuracy statistically indistinguishable from T-Coffee and MAFFT, and is the fastest of the tested methods for large numbers of sequences, aligning 5000 sequences of average length 350 in 7 min on a current desktop computer. The MUSCLE program, source code and PREFAB test data are freely available at http://www.drive5. com/muscle.

  3. High Accuracy Evaluation of the Finite Fourier Transform Using Sampled Data

    Science.gov (United States)

    Morelli, Eugene A.

    1997-01-01

    Many system identification and signal processing procedures can be done advantageously in the frequency domain. A required preliminary step for this approach is the transformation of sampled time domain data into the frequency domain. The analytical tool used for this transformation is the finite Fourier transform. Inaccuracy in the transformation can degrade system identification and signal processing results. This work presents a method for evaluating the finite Fourier transform using cubic interpolation of sampled time domain data for high accuracy, and the chirp Zeta-transform for arbitrary frequency resolution. The accuracy of the technique is demonstrated in example cases where the transformation can be evaluated analytically. Arbitrary frequency resolution is shown to be important for capturing details of the data in the frequency domain. The technique is demonstrated using flight test data from a longitudinal maneuver of the F-18 High Alpha Research Vehicle.

  4. Precision Orbit of δ Delphini and Prospects for Astrometric Detection of Exoplanets

    Science.gov (United States)

    Gardner, Tyler; Monnier, John D.; Fekel, Francis C.; Williamson, Mike; Duncan, Douglas K.; White, Timothy R.; Ireland, Michael; Adams, Fred C.; Barman, Travis; Baron, Fabien; ten Brummelaar, Theo; Che, Xiao; Huber, Daniel; Kraus, Stefan; Roettenbacher, Rachael M.; Schaefer, Gail; Sturmann, Judit; Sturmann, Laszlo; Swihart, Samuel J.; Zhao, Ming

    2018-03-01

    Combining visual and spectroscopic orbits of binary stars leads to a determination of the full 3D orbit, individual masses, and distance to the system. We present a full analysis of the evolved binary system δ Delphini using astrometric data from the MIRC and PAVO instruments on the CHARA long-baseline interferometer, 97 new spectra from the Fairborn Observatory, and 87 unpublished spectra from the Lick Observatory. We determine the full set of orbital elements for δ Del, along with masses of 1.78 ± 0.07 M ⊙ and 1.62 ± 0.07 M ⊙ for each component, and a distance of 63.61 ± 0.89 pc. These results are important in two contexts: for testing stellar evolution models and for defining the detection capabilities for future planet searches. We find that the evolutionary state of this system is puzzling, as our measured flux ratios, radii, and masses imply a ∼200 Myr age difference between the components, using standard stellar evolution models. Possible explanations for this age discrepancy include mass transfer scenarios with a now-ejected tertiary companion. For individual measurements taken over a span of two years, we achieve 2 M J on orbits >0.75 au around individual components of hot binary stars via differential astrometry.

  5. High accuracy interface characterization of three phase material systems in three dimensions

    DEFF Research Database (Denmark)

    Jørgensen, Peter Stanley; Hansen, Karin Vels; Larsen, Rasmus

    2010-01-01

    Quantification of interface properties such as two phase boundary area and triple phase boundary length is important in the characterization ofmanymaterial microstructures, in particular for solid oxide fuel cell electrodes. Three-dimensional images of these microstructures can be obtained...... by tomography schemes such as focused ion beam serial sectioning or micro-computed tomography. We present a high accuracy method of calculating two phase surface areas and triple phase length of triple phase systems from subvoxel accuracy segmentations of constituent phases. The method performs a three phase...... polygonization of the interface boundaries which results in a non-manifold mesh of connected faces. We show how the triple phase boundaries can be extracted as connected curve loops without branches. The accuracy of the method is analyzed by calculations on geometrical primitives...

  6. HOW GOOD ARE FUTURE LAWYERS IN JUDGING THE ACCURACY OF REMINISCENT DETAILS? THE ESTIMATION-OBSERVATION GAP IN REAL EYEWITNESS ACCOUNTS

    Directory of Open Access Journals (Sweden)

    Aileen Oeberst

    2015-07-01

    Full Text Available Research has shown a discrepancy between estimated and actually observed accuracy of reminiscent details in eyewitness accounts. This estimation-observation gap is of particular relevance with regard to the evaluation of eyewitnesses’ accounts in the legal context. To date it has only been demonstrated in non-naturalistic settings, however. In addition, it is not known whether this gap extends to other tasks routinely employed in real-world trials, for instance person-identification tasks. In this study, law students witnessed a staged event and were asked to either recall the event and perform a person identification task or estimate the accuracy of the others’ performance. Additionally, external estimations were obtained from students who had not witnessed the event, but received a written summary instead. The estimation-observation gap was replicated for reminiscent details under naturalistic encoding conditions. This gap was more pronounced when compared to forgotten details, but not significantly so when compared to consistent details. In contrast, accuracy on the person-identification task was not consistently underestimated. The results are discussed in light of their implications for real-world trials and future research.

  7. A Smart High Accuracy Silicon Piezoresistive Pressure Sensor Temperature Compensation System

    Directory of Open Access Journals (Sweden)

    Guanwu Zhou

    2014-07-01

    Full Text Available Theoretical analysis in this paper indicates that the accuracy of a silicon piezoresistive pressure sensor is mainly affected by thermal drift, and varies nonlinearly with the temperature. Here, a smart temperature compensation system to reduce its effect on accuracy is proposed. Firstly, an effective conditioning circuit for signal processing and data acquisition is designed. The hardware to implement the system is fabricated. Then, a program is developed on LabVIEW which incorporates an extreme learning machine (ELM as the calibration algorithm for the pressure drift. The implementation of the algorithm was ported to a micro-control unit (MCU after calibration in the computer. Practical pressure measurement experiments are carried out to verify the system’s performance. The temperature compensation is solved in the interval from −40 to 85 °C. The compensated sensor is aimed at providing pressure measurement in oil-gas pipelines. Compared with other algorithms, ELM acquires higher accuracy and is more suitable for batch compensation because of its higher generalization and faster learning speed. The accuracy, linearity, zero temperature coefficient and sensitivity temperature coefficient of the tested sensor are 2.57% FS, 2.49% FS, 8.1 × 10−5/°C and 29.5 × 10−5/°C before compensation, and are improved to 0.13%FS, 0.15%FS, 1.17 × 10−5/°C and 2.1 × 10−5/°C respectively, after compensation. The experimental results demonstrate that the proposed system is valid for the temperature compensation and high accuracy requirement of the sensor.

  8. Accuracy of Single Frequency GPS Observations Processing In Near Real-time With Use of Code Predicted Products

    Science.gov (United States)

    Wielgosz, P. A.

    In this year, the system of active geodetic GPS permanent stations is going to be estab- lished in Poland. This system should provide GPS observations for a wide spectrum of users, especially it will be a great opportunity for surveyors. Many of surveyors still use cheaper, single frequency receivers. This paper focuses on processing of single frequency GPS observations only. During processing of such observations the iono- sphere plays an important role, so we concentrated on the influence of the ionosphere on the positional coordinates. Twenty consecutive days of GPS data from 2001 year were processed to analyze the accuracy of a derived three-dimensional relative vec- tor position between GPS stations. Observations from two Polish EPN/IGS stations: BOGO and JOZE were used. In addition to, a new test station - IGIK was created. In this paper, the results of single frequency GPS observations processing in near real- time are presented. Baselines of 15, 27 and 42 kilometers and sessions of 1, 2, 3, 4, and 6 hours long were processed. While processing we used CODE (Centre for Orbit De- termination in Europe, Bern, Switzerland) predicted products: orbits and ionosphere info. These products are available in real-time and enable near real-time processing. Software Bernese v. 4.2 for Linux and BPE (Bernese Processing Engine) mode were used. These results are shown with a reference to dual frequency weekly solution (the best solution). Obtained GPS positional time and GPS baseline length dependency accuracy is presented for single frequency GPS observations.

  9. Continuing Improvement in the Planetary Ephemeris with VLBA Observations of Cassini

    Science.gov (United States)

    Jones, Dayton L.; Folkner, William M.; Jacobson, Robert A.; Jacobs, Christopher S.; Romney, Jonathan D.; Dhawan, Vivek; Fomalont, Edward B.

    2016-06-01

    During the past decade a continuing series of measurements of the barycentric position of the Saturn system in the inertial International Celestial Reference Frame (ICRF) has led to a significant improvement in our knowledge of Saturn's orbit. This in turn has improved the current accuracy and time range of the solar system ephemeris produced and maintained by the Jet Propulsion Laboratory. Our observing technique involves high-precision astrometry of the radio signal from Cassini with the NRAO Very Long Baseline Array, combined with solutions for the orbital motion of Cassini about the Saturn barycenter from Doppler tracking by the Deep Space Network. Our VLBA astrometry is done in a phase-referencing mode, providing nrad-level relative positions between Cassini and angularly nearby extragalactic radio sources. The positions of those reference radio sources are tied to the ICRF through dedicated VLBI observations by several groups around the world. We will present recent results from our astrometric observations of Cassini through early 2016. This program will continue until the end of the Cassini mission in 2017, although future improvement in Saturn's orbit will be more incremental because we have already covered more that a quarter of Saturn's orbital period. The Juno mission to Jupiter, which will orbit Jupiter for about 1.5 years starting in July 2016, will provide an excellent opportunity for us to apply the same VLBA astrometry technique to improve the orbit of Jupiter by a factor of several. The National Radio Astronomy Observatory is a facility of the National Science Foundation operated under cooperative agreement by Associated Universities, Inc. This work made use of the Swinburne University of Technology software correlator, developed as part of the Australian Major National Research Facilities Program and operated under license. Part of this research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under contract

  10. Design of a basic angle monitoring system in Silicon Carbide

    NARCIS (Netherlands)

    Veggel, van A.A.; Rosielle, P.C.J.N.; Nijmeijer, H.; Wielders, A.A.; Vink, H.J.P.

    2005-01-01

    Due to the 10 microarcsecond accuracy, with which GAIA will measure the positions of stars using 2 astrometric telescopes, stability requirements on the payload module are extremely stringent. In order to achieve the required 10 microarcsecond accuracy, a metrology system could be installed on the

  11. Ultra-high accuracy optical testing: creating diffraction-limitedshort-wavelength optical systems

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Kenneth A.; Naulleau, Patrick P.; Rekawa, Senajith B.; Denham, Paul E.; Liddle, J. Alexander; Gullikson, Eric M.; Jackson, KeithH.; Anderson, Erik H.; Taylor, John S.; Sommargren, Gary E.; Chapman,Henry N.; Phillion, Donald W.; Johnson, Michael; Barty, Anton; Soufli,Regina; Spiller, Eberhard A.; Walton, Christopher C.; Bajt, Sasa

    2005-08-03

    Since 1993, research in the fabrication of extreme ultraviolet (EUV) optical imaging systems, conducted at Lawrence Berkeley National Laboratory (LBNL) and Lawrence Livermore National Laboratory (LLNL), has produced the highest resolution optical systems ever made. We have pioneered the development of ultra-high-accuracy optical testing and alignment methods, working at extreme ultraviolet wavelengths, and pushing wavefront-measuring interferometry into the 2-20-nm wavelength range (60-600 eV). These coherent measurement techniques, including lateral shearing interferometry and phase-shifting point-diffraction interferometry (PS/PDI) have achieved RMS wavefront measurement accuracies of 0.5-1-{angstrom} and better for primary aberration terms, enabling the creation of diffraction-limited EUV optics. The measurement accuracy is established using careful null-testing procedures, and has been verified repeatedly through high-resolution imaging. We believe these methods are broadly applicable to the advancement of short-wavelength optical systems including space telescopes, microscope objectives, projection lenses, synchrotron beamline optics, diffractive and holographic optics, and more. Measurements have been performed on a tunable undulator beamline at LBNL's Advanced Light Source (ALS), optimized for high coherent flux; although many of these techniques should be adaptable to alternative ultraviolet, EUV, and soft x-ray light sources. To date, we have measured nine prototype all-reflective EUV optical systems with NA values between 0.08 and 0.30 (f/6.25 to f/1.67). These projection-imaging lenses were created for the semiconductor industry's advanced research in EUV photolithography, a technology slated for introduction in 2009-13. This paper reviews the methods used and our program's accomplishments to date.

  12. NiftyPET: a High-throughput Software Platform for High Quantitative Accuracy and Precision PET Imaging and Analysis.

    Science.gov (United States)

    Markiewicz, Pawel J; Ehrhardt, Matthias J; Erlandsson, Kjell; Noonan, Philip J; Barnes, Anna; Schott, Jonathan M; Atkinson, David; Arridge, Simon R; Hutton, Brian F; Ourselin, Sebastien

    2018-01-01

    We present a standalone, scalable and high-throughput software platform for PET image reconstruction and analysis. We focus on high fidelity modelling of the acquisition processes to provide high accuracy and precision quantitative imaging, especially for large axial field of view scanners. All the core routines are implemented using parallel computing available from within the Python package NiftyPET, enabling easy access, manipulation and visualisation of data at any processing stage. The pipeline of the platform starts from MR and raw PET input data and is divided into the following processing stages: (1) list-mode data processing; (2) accurate attenuation coefficient map generation; (3) detector normalisation; (4) exact forward and back projection between sinogram and image space; (5) estimation of reduced-variance random events; (6) high accuracy fully 3D estimation of scatter events; (7) voxel-based partial volume correction; (8) region- and voxel-level image analysis. We demonstrate the advantages of this platform using an amyloid brain scan where all the processing is executed from a single and uniform computational environment in Python. The high accuracy acquisition modelling is achieved through span-1 (no axial compression) ray tracing for true, random and scatter events. Furthermore, the platform offers uncertainty estimation of any image derived statistic to facilitate robust tracking of subtle physiological changes in longitudinal studies. The platform also supports the development of new reconstruction and analysis algorithms through restricting the axial field of view to any set of rings covering a region of interest and thus performing fully 3D reconstruction and corrections using real data significantly faster. All the software is available as open source with the accompanying wiki-page and test data.

  13. High-accuracy self-mixing interferometer based on single high-order orthogonally polarized feedback effects.

    Science.gov (United States)

    Zeng, Zhaoli; Qu, Xueming; Tan, Yidong; Tan, Runtao; Zhang, Shulian

    2015-06-29

    A simple and high-accuracy self-mixing interferometer based on single high-order orthogonally polarized feedback effects is presented. The single high-order feedback effect is realized when dual-frequency laser reflects numerous times in a Fabry-Perot cavity and then goes back to the laser resonator along the same route. In this case, two orthogonally polarized feedback fringes with nanoscale resolution are obtained. This self-mixing interferometer has the advantages of higher sensitivity to weak signal than that of conventional interferometer. In addition, two orthogonally polarized fringes are useful for discriminating the moving direction of measured object. The experiment of measuring 2.5nm step is conducted, which shows a great potential in nanometrology.

  14. Automated novel high-accuracy miniaturized positioning system for use in analytical instrumentation

    Science.gov (United States)

    Siomos, Konstadinos; Kaliakatsos, John; Apostolakis, Manolis; Lianakis, John; Duenow, Peter

    1996-01-01

    The development of three-dimensional automotive devices (micro-robots) for applications in analytical instrumentation, clinical chemical diagnostics and advanced laser optics, depends strongly on the ability of such a device: firstly to be positioned with high accuracy, reliability, and automatically, by means of user friendly interface techniques; secondly to be compact; and thirdly to operate under vacuum conditions, free of most of the problems connected with conventional micropositioners using stepping-motor gear techniques. The objective of this paper is to develop and construct a mechanically compact computer-based micropositioning system for coordinated motion in the X-Y-Z directions with: (1) a positioning accuracy of less than 1 micrometer, (the accuracy of the end-position of the system is controlled by a hard/software assembly using a self-constructed optical encoder); (2) a heat-free propulsion mechanism for vacuum operation; and (3) synchronized X-Y motion.

  15. High-Accuracy Measurements of Total Column Water Vapor From the Orbiting Carbon Observatory-2

    Science.gov (United States)

    Nelson, Robert R.; Crisp, David; Ott, Lesley E.; O'Dell, Christopher W.

    2016-01-01

    Accurate knowledge of the distribution of water vapor in Earth's atmosphere is of critical importance to both weather and climate studies. Here we report on measurements of total column water vapor (TCWV) from hyperspectral observations of near-infrared reflected sunlight over land and ocean surfaces from the Orbiting Carbon Observatory-2 (OCO-2). These measurements are an ancillary product of the retrieval algorithm used to measure atmospheric carbon dioxide concentrations, with information coming from three highly resolved spectral bands. Comparisons to high-accuracy validation data, including ground-based GPS and microwave radiometer data, demonstrate that OCO-2 TCWV measurements have maximum root-mean-square deviations of 0.9-1.3mm. Our results indicate that OCO-2 is the first space-based sensor to accurately and precisely measure the two most important greenhouse gases, water vapor and carbon dioxide, at high spatial resolution [1.3 x 2.3 km(exp. 2)] and that OCO-2 TCWV measurements may be useful in improving numerical weather predictions and reanalysis products.

  16. Identification and delineation of areas flood hazard using high accuracy of DEM data

    Science.gov (United States)

    Riadi, B.; Barus, B.; Widiatmaka; Yanuar, M. J. P.; Pramudya, B.

    2018-05-01

    Flood incidents that often occur in Karawang regency need to be mitigated. These expectations exist on technologies that can predict, anticipate and reduce disaster risks. Flood modeling techniques using Digital Elevation Model (DEM) data can be applied in mitigation activities. High accuracy DEM data used in modeling, will result in better flooding flood models. The result of high accuracy DEM data processing will yield information about surface morphology which can be used to identify indication of flood hazard area. The purpose of this study was to identify and describe flood hazard areas by identifying wetland areas using DEM data and Landsat-8 images. TerraSAR-X high-resolution data is used to detect wetlands from landscapes, while land cover is identified by Landsat image data. The Topography Wetness Index (TWI) method is used to detect and identify wetland areas with basic DEM data, while for land cover analysis using Tasseled Cap Transformation (TCT) method. The result of TWI modeling yields information about potential land of flood. Overlay TWI map with land cover map that produces information that in Karawang regency the most vulnerable areas occur flooding in rice fields. The spatial accuracy of the flood hazard area in this study was 87%.

  17. Accuracy of Estimating Highly Eccentric Binary Black Hole Parameters with Gravitational-wave Detections

    Science.gov (United States)

    Gondán, László; Kocsis, Bence; Raffai, Péter; Frei, Zsolt

    2018-03-01

    Mergers of stellar-mass black holes on highly eccentric orbits are among the targets for ground-based gravitational-wave detectors, including LIGO, VIRGO, and KAGRA. These sources may commonly form through gravitational-wave emission in high-velocity dispersion systems or through the secular Kozai–Lidov mechanism in triple systems. Gravitational waves carry information about the binaries’ orbital parameters and source location. Using the Fisher matrix technique, we determine the measurement accuracy with which the LIGO–VIRGO–KAGRA network could measure the source parameters of eccentric binaries using a matched filtering search of the repeated burst and eccentric inspiral phases of the waveform. We account for general relativistic precession and the evolution of the orbital eccentricity and frequency during the inspiral. We find that the signal-to-noise ratio and the parameter measurement accuracy may be significantly higher for eccentric sources than for circular sources. This increase is sensitive to the initial pericenter distance, the initial eccentricity, and the component masses. For instance, compared to a 30 {M}ȯ –30 {M}ȯ non-spinning circular binary, the chirp mass and sky-localization accuracy can improve by a factor of ∼129 (38) and ∼2 (11) for an initially highly eccentric binary assuming an initial pericenter distance of 20 M tot (10 M tot).

  18. Medication adherence assessment: high accuracy of the new Ingestible Sensor System in kidney transplants.

    Science.gov (United States)

    Eisenberger, Ute; Wüthrich, Rudolf P; Bock, Andreas; Ambühl, Patrice; Steiger, Jürg; Intondi, Allison; Kuranoff, Susan; Maier, Thomas; Green, Damian; DiCarlo, Lorenzo; Feutren, Gilles; De Geest, Sabina

    2013-08-15

    This open-label single-arm exploratory study evaluated the accuracy of the Ingestible Sensor System (ISS), a novel technology for directly assessing the ingestion of oral medications and treatment adherence. ISS consists of an ingestible event marker (IEM), a microsensor that becomes activated in gastric fluid, and an adhesive personal monitor (APM) that detects IEM activation. In this study, the IEM was combined to enteric-coated mycophenolate sodium (ECMPS). Twenty stable adult kidney transplants received IEM-ECMPS for a mean of 9.2 weeks totaling 1227 cumulative days. Eight patients prematurely discontinued treatment due to ECMPS gastrointestinal symptoms (n=2), skin intolerance to APM (n=2), and insufficient system usability (n=4). Rash or erythema due to APM was reported in 7 (37%) patients, all during the first month of use. No serious or severe adverse events and no rejection episode were reported. IEM detection accuracy was 100% over 34 directly observed ingestions; Taking Adherence was 99.4% over a total of 2824 prescribed IEM-ECMPS ingestions. ISS could detect accurately the ingestion of two IEM-ECMPS capsules taken at the same time (detection rate of 99.3%, n=2376). ISS is a promising new technology that provides highly reliable measurements of intake and timing of intake of drugs that are combined with the IEM.

  19. Accurate procedure for deriving UTI at a submilliarcsecond accuracy from Greenwich Sidereal Time or from the stellar angle

    Science.gov (United States)

    Capitaine, N.; Gontier, A.-M.

    1993-08-01

    Present observations using modern astrometric techniques are supposed to provide the Earth orientation parameters, and therefore UT1, with an accuracy better than ±1 mas. In practice, UT1 is determined through the intermediary of Greenwich Sidereal Time (GST), using both the conventional relationship between Greenwich Mean Sidereal Time (GMST) and UTl (Aoki et al. 1982) and the so-called "equation of the equinoxes" limited to the first order terms with respect to the nutation quantities. This highly complex relation between sidereal time and UT1 is not accurate at the milliaresecond level which gives rise to spurious terms of milliaresecond amplitude in the derived UTl. A more complete relationship between GST and UT1 has been recommended by Aoki & Kinoshita (1983) and Aoki (1991) taking into account the second order terms in the difference between GST and GM ST, the largest one having an amplitude of 2.64 mas and a 18.6 yr-period. This paper explains how this complete expansion of GST implicitly uses the concept of "nonrotating origin" (NRO) as proposed by Guinot in 1979 and would, therefore, provide a more accurate value of UTl and consequently of the Earth's angular velocity. This paper shows, moreover, that such a procedure would be simplified and conceptually clarified by the explicit use of the NRO as previously proposed (Guinot 1979; Capitaine et al. 1986). The two corresponding options (implicit or explicit use of the NRO) are shown to be equivalent for defining the specific Earth's angle of rotation and then UT1. The of the use of such an accurate procedure which has been proposed in the new IERS standards (McCarthy 1992a) instead of the usual one are estimated for the practical derivation of UT1.

  20. High accuracy positioning using carrier-phases with the opensource GPSTK software

    OpenAIRE

    Salazar Hernández, Dagoberto José; Hernández Pajares, Manuel; Juan Zornoza, José Miguel; Sanz Subirana, Jaume

    2008-01-01

    The objective of this work is to show how using a proper GNSS data management strategy, combined with the flexibility provided by the open source "GPS Toolkit" (GPSTk), it is possible to easily develop both simple code-based processing strategies as well as basic high accuracy carrier-phase positioning techniques like Precise Point Positioning (PPP

  1. Intra- and inter-observer variability and accuracy in the determination of linear and angular measurements in computed tomography

    International Nuclear Information System (INIS)

    Christiansen, E.L.; Thompson, J.R.; Kopp, S.

    1986-01-01

    The observer variability and accuracy of linear and angular computed tomography (CT) software measurements in the transaxial plane were investigated for the temporomandibular joint with the General Electric 8800 CT/N Scanner. A dried and measured human mandible was embedded in plastic and scanned in vitro. Sixteen observers participated in the study. The following measurements were tested: inter- and extra-condylar distances, transverse condylar dimension, condylar angulation, and the plastic base of the specimen. Three frozen cadaveric heads were similarly scanned and measured in situ. Intra- and inter-observer variabilities were lowest for the specimen base and highest for condylar angulation. Neuroradiologists had the lowest variability as a group, and the radiology residents and paramedical personell had the highest, but the differences were small. No significant difference was found between CT and macroscopic measurement of the mandible. In situ measurement by CT of condyles with structural changes in the transaxial plane was, however, subject to substantial error. It was concluded that transaxial linear measurements of the condylar processes free of significant structural changes had an error and an accuracy well within acceptable limits. The error for angular measurements was significantly greater than the error for linear measurements

  2. A New Approach to High-accuracy Road Orthophoto Mapping Based on Wavelet Transform

    Directory of Open Access Journals (Sweden)

    Ming Yang

    2011-12-01

    Full Text Available Existing orthophoto map based on satellite photography and aerial photography is not precise enough for road marking. This paper proposes a new approach to high-accuracy orthophoto mapping. The approach uses inverse perspective transformation to process the image information and generates the orthophoto fragment. The offline interpolation algorithm is used to process the location information. It processes the dead reckoning and the EKF location information, and uses the result to transform the fragments to the global coordinate system. At last it uses wavelet transform to divides the image to two frequency bands and uses weighted median algorithm to deal with them separately. The result of experiment shows that the map produced with this method has high accuracy.

  3. A new ultra-high-accuracy angle generator: current status and future direction

    Science.gov (United States)

    Guertin, Christian F.; Geckeler, Ralf D.

    2017-09-01

    Lack of an extreme high-accuracy angular positioning device available in the United States has left a gap in industrial and scientific efforts conducted there, requiring certain user groups to undertake time-consuming work with overseas laboratories. Specifically, in x-ray mirror metrology the global research community is advancing the state-of-the-art to unprecedented levels. We aim to fill this U.S. gap by developing a versatile high-accuracy angle generator as a part of the national metrology tool set for x-ray mirror metrology and other important industries. Using an established calibration technique to measure the errors of the encoder scale graduations for full-rotation rotary encoders, we implemented an optimized arrangement of sensors positioned to minimize propagation of calibration errors. Our initial feasibility research shows that upon scaling to a full prototype and including additional calibration techniques we can expect to achieve uncertainties at the level of 0.01 arcsec (50 nrad) or better and offer the immense advantage of a highly automatable and customizable product to the commercial market.

  4. Ultra-high accuracy optical testing: creating diffraction-limited short-wavelength optical systems

    International Nuclear Information System (INIS)

    Goldberg, Kenneth A.; Naulleau, Patrick P.; Rekawa, Senajith B.; Denham, Paul E.; Liddle, J. Alexander; Gullikson, Eric M.; Jackson, KeithH.; Anderson, Erik H.; Taylor, John S.; Sommargren, Gary E.; Chapman, Henry N.; Phillion, Donald W.; Johnson, Michael; Barty, Anton; Soufli, Regina; Spiller, Eberhard A.; Walton, Christopher C.; Bajt, Sasa

    2005-01-01

    Since 1993, research in the fabrication of extreme ultraviolet (EUV) optical imaging systems, conducted at Lawrence Berkeley National Laboratory (LBNL) and Lawrence Livermore National Laboratory (LLNL), has produced the highest resolution optical systems ever made. We have pioneered the development of ultra-high-accuracy optical testing and alignment methods, working at extreme ultraviolet wavelengths, and pushing wavefront-measuring interferometry into the 2-20-nm wavelength range (60-600 eV). These coherent measurement techniques, including lateral shearing interferometry and phase-shifting point-diffraction interferometry (PS/PDI) have achieved RMS wavefront measurement accuracies of 0.5-1-(angstrom) and better for primary aberration terms, enabling the creation of diffraction-limited EUV optics. The measurement accuracy is established using careful null-testing procedures, and has been verified repeatedly through high-resolution imaging. We believe these methods are broadly applicable to the advancement of short-wavelength optical systems including space telescopes, microscope objectives, projection lenses, synchrotron beamline optics, diffractive and holographic optics, and more. Measurements have been performed on a tunable undulator beamline at LBNL's Advanced Light Source (ALS), optimized for high coherent flux; although many of these techniques should be adaptable to alternative ultraviolet, EUV, and soft x-ray light sources. To date, we have measured nine prototype all-reflective EUV optical systems with NA values between 0.08 and 0.30 (f/6.25 to f/1.67). These projection-imaging lenses were created for the semiconductor industry's advanced research in EUV photolithography, a technology slated for introduction in 2009-13. This paper reviews the methods used and our program's accomplishments to date

  5. Experimental set-up for testing alignments and measurement stability of a metrology system in Silicon Carbide for GAIA

    NARCIS (Netherlands)

    Veggel, van A.A.; Wielders, A.A.; Brug, van H.; Rosielle, P.C.J.N.; Nijmeijer, H.; Hatheway, A.E.

    2005-01-01

    The GAIA satellite will make a 3-D map of our Galaxy with measurement accuracy of 10 microarcseconds using two astrometric telescopes. The angle between the lines-of-sight of the two telescopes will be monitored using the Basic Angle Monitoring system with 1 microarcsecond accuracy. This system will

  6. Diagnosing Eyewitness Accuracy

    OpenAIRE

    Russ, Andrew

    2015-01-01

    Eyewitnesses frequently mistake innocent people for the perpetrator of an observed crime. Such misidentifications have led to the wrongful convictions of many people. Despite this, no reliable method yet exists to determine eyewitness accuracy. This thesis explored two new experimental methods for this purpose. Chapter 2 investigated whether repetition priming can measure prior exposure to a target and compared this with observers’ explicit eyewitness accuracy. Across three experiments slower...

  7. An accuracy assessment of realtime GNSS time series toward semi- real time seafloor geodetic observation

    Science.gov (United States)

    Osada, Y.; Ohta, Y.; Demachi, T.; Kido, M.; Fujimoto, H.; Azuma, R.; Hino, R.

    2013-12-01

    Large interplate earthquake repeatedly occurred in Japan Trench. Recently, the detail crustal deformation revealed by the nation-wide inland GPS network called as GEONET by GSI. However, the maximum displacement region for interplate earthquake is mainly located offshore region. GPS/Acoustic seafloor geodetic observation (hereafter GPS/A) is quite important and useful for understanding of shallower part of the interplate coupling between subducting and overriding plates. We typically conduct GPS/A in specific ocean area based on repeated campaign style using research vessel or buoy. Therefore, we cannot monitor the temporal variation of seafloor crustal deformation in real time. The one of technical issue on real time observation is kinematic GPS analysis because kinematic GPS analysis based on reference and rover data. If the precise kinematic GPS analysis will be possible in the offshore region, it should be promising method for real time GPS/A with USV (Unmanned Surface Vehicle) and a moored buoy. We assessed stability, precision and accuracy of StarFireTM global satellites based augmentation system. We primarily tested for StarFire in the static condition. In order to assess coordinate precision and accuracy, we compared 1Hz StarFire time series and post-processed precise point positioning (PPP) 1Hz time series by GIPSY-OASIS II processing software Ver. 6.1.2 with three difference product types (ultra-rapid, rapid, and final orbits). We also used difference interval clock information (30 and 300 seconds) for the post-processed PPP processing. The standard deviation of real time StarFire time series is less than 30 mm (horizontal components) and 60 mm (vertical component) based on 1 month continuous processing. We also assessed noise spectrum of the estimated time series by StarFire and post-processed GIPSY PPP results. We found that the noise spectrum of StarFire time series is similar pattern with GIPSY-OASIS II processing result based on JPL rapid orbit

  8. Update on Spacewatch Observations of Near-Earth Objects

    Science.gov (United States)

    Brucker, Melissa; McMillan, Robert S.; Bressi, Terry; Larsen, Jeff; Mastaler, Ron; Read, Mike; Scotti, Jim; Tubbiolo, Andrew

    2017-10-01

    Spacewatch performs targeted astrometric follow-up of near-Earth objects, primarily asteroids (NEAs), to improve knowledge of their orbits. We have a noteworthy history of asteroid and comet observations beginning in 1984 as the first survey to use CCDs to scan the sky for asteroids and comets. Currently, we measure simultaneous astrometry and photometry of observations during an average of 24 nights per lunation (dark and gray time) as the exclusive users of a 1.8-m telescope and a 0.9-m telescope on Kitt Peak. In addition, we use bright time on the 2.3-m Bok Telescope and the 4-m Mayall Telescope on Kitt Peak to chase fainter targets. Continued astrometric follow-up helps to prevent potentially hazardous objects and scientifically interesting NEAs from becoming lost.We prioritize virtual impactors, MPC confirmation page objects, potentially hazardous asteroids (PHAs) with close approaches within 0.03 AU in the next 30 years, upcoming radar targets with astrometry requests, Yarkovsky effect candidates, NEAs with existing characterization data (WISE, Spitzer, SMASS, MANOS), possible spacecraft destinations (NHATS), and requests from the community.In mid October 2015, we switched from survey mode to targeted astrometry on the 0.9-m telescope. From 2015 October 15 through 2017 June 29 (1.7yr), Spacewatch (observatory codes 291, 691, and ^695) had 20951 MPC-accepted NEO lines of astrometry corresponding to measurements of 2647 different NEOs. This includes 4801 PHA lines of astrometry corresponding to 426 different PHAs, of which 223 lines were at apparent magnitudes V>=22.5. We observed 43% of all NEAs and 52% of all unnumbered NEAs that were observed by any observatory during that period. We observed 50% of all PHAs and 64% of all unnumbered PHAs observed during that period. These statistics do not include submitted measurements of confirmation page objects that were not confirmed as NEAs.Support of Spacewatch is from NASA/NEOO grants, the Lunar and Planetary

  9. Location accuracy evaluation of lightning location systems using natural lightning flashes recorded by a network of high-speed cameras

    Science.gov (United States)

    Alves, J.; Saraiva, A. C. V.; Campos, L. Z. D. S.; Pinto, O., Jr.; Antunes, L.

    2014-12-01

    This work presents a method for the evaluation of location accuracy of all Lightning Location System (LLS) in operation in southeastern Brazil, using natural cloud-to-ground (CG) lightning flashes. This can be done through a multiple high-speed cameras network (RAMMER network) installed in the Paraiba Valley region - SP - Brazil. The RAMMER network (Automated Multi-camera Network for Monitoring and Study of Lightning) is composed by four high-speed cameras operating at 2,500 frames per second. Three stationary black-and-white (B&W) cameras were situated in the cities of São José dos Campos and Caçapava. A fourth color camera was mobile (installed in a car), but operated in a fixed location during the observation period, within the city of São José dos Campos. The average distance among cameras was 13 kilometers. Each RAMMER sensor position was determined so that the network can observe the same lightning flash from different angles and all recorded videos were GPS (Global Position System) time stamped, allowing comparisons of events between cameras and the LLS. The RAMMER sensor is basically composed by a computer, a Phantom high-speed camera version 9.1 and a GPS unit. The lightning cases analyzed in the present work were observed by at least two cameras, their position was visually triangulated and the results compared with BrasilDAT network, during the summer seasons of 2011/2012 and 2012/2013. The visual triangulation method is presented in details. The calibration procedure showed an accuracy of 9 meters between the accurate GPS position of the object triangulated and the result from the visual triangulation method. Lightning return stroke positions, estimated with the visual triangulation method, were compared with LLS locations. Differences between solutions were not greater than 1.8 km.

  10. ASTROMETRY AND RADIAL VELOCITIES OF THE PLANET HOST M DWARF GJ 317: NEW TRIGONOMETRIC DISTANCE, METALLICITY, AND UPPER LIMIT TO THE MASS OF GJ 317b

    International Nuclear Information System (INIS)

    Anglada-Escudé, Guillem; Boss, Alan P.; Weinberger, Alycia J.; Butler, R. Paul; Thompson, Ian B.; Vogt, Steven S.; Rivera, Eugenio J.

    2012-01-01

    We have obtained precision astrometry of the planet host M dwarf GJ 317 in the framework of the Carnegie Astrometric Planet Search project. The new astrometric measurements give a distance determination of 15.3 pc, 65% further than previous estimates. The resulting absolute magnitudes suggest that it is metal-rich and more massive than previously assumed. This result strengthens the correlation between high metallicity and the presence of gas giants around low-mass stars. At 15.3 pc, the minimal astrometric amplitude for planet candidate GJ 317b is 0.3 mas (edge-on orbit), just below our astrometric sensitivity. However, given the relatively large number of observations and good astrometric precision, a Bayesian Monte Carlo Markov Chain analysis indicates that the mass of planet b has to be smaller than twice the minimum mass with a 99% confidence level, with a most likely value of 2.5 M Jup . Additional radial velocity (RV) measurements obtained with Keck by the Lick-Carnegie Planet search program confirm the presence of an additional very long period planet candidate, with a period of 20 years or more. Even though such an object will imprint a large astrometric wobble on the star, its curvature is yet not evident in the astrometry. Given high metallicity, and the trend indicating that multiple systems are rich in low-mass companions, this system is likely to host additional low-mass planets in its habitable zone that can be readily detected with state-of-the-art optical and near-infrared RV measurements.

  11. ASTROMETRY AND RADIAL VELOCITIES OF THE PLANET HOST M DWARF GJ 317: NEW TRIGONOMETRIC DISTANCE, METALLICITY, AND UPPER LIMIT TO THE MASS OF GJ 317b

    Energy Technology Data Exchange (ETDEWEB)

    Anglada-Escude, Guillem; Boss, Alan P.; Weinberger, Alycia J.; Butler, R. Paul [Department of Terrestrial Magnetism, Carnegie Institution for Science, 5241 Broad Branch Road NW, Washington, DC 20015 (United States); Thompson, Ian B. [Carnegie Observatories, 813 Santa Barbara Street, Pasadena, CA 91101 (United States); Vogt, Steven S.; Rivera, Eugenio J., E-mail: anglada@dtm.ciw.edu [UCO/Lick Observatory, University of California, Santa Cruz, CA 95064 (United States)

    2012-02-10

    We have obtained precision astrometry of the planet host M dwarf GJ 317 in the framework of the Carnegie Astrometric Planet Search project. The new astrometric measurements give a distance determination of 15.3 pc, 65% further than previous estimates. The resulting absolute magnitudes suggest that it is metal-rich and more massive than previously assumed. This result strengthens the correlation between high metallicity and the presence of gas giants around low-mass stars. At 15.3 pc, the minimal astrometric amplitude for planet candidate GJ 317b is 0.3 mas (edge-on orbit), just below our astrometric sensitivity. However, given the relatively large number of observations and good astrometric precision, a Bayesian Monte Carlo Markov Chain analysis indicates that the mass of planet b has to be smaller than twice the minimum mass with a 99% confidence level, with a most likely value of 2.5 M{sub Jup}. Additional radial velocity (RV) measurements obtained with Keck by the Lick-Carnegie Planet search program confirm the presence of an additional very long period planet candidate, with a period of 20 years or more. Even though such an object will imprint a large astrometric wobble on the star, its curvature is yet not evident in the astrometry. Given high metallicity, and the trend indicating that multiple systems are rich in low-mass companions, this system is likely to host additional low-mass planets in its habitable zone that can be readily detected with state-of-the-art optical and near-infrared RV measurements.

  12. High-accuracy alignment based on atmospherical dispersion - technological approaches and solutions for the dual-wavelength transmitter

    International Nuclear Information System (INIS)

    Burkhard, Boeckem

    1999-01-01

    In the course of the progressive developments of sophisticated geodetic systems utilizing electromagnetic waves in the visible or near IR-range a more detailed knowledge of the propagation medium and coevally solutions of atmospherically induced limitations will become important. An alignment system based on atmospherical dispersion, called a dispersometer, is a metrological solution to the atmospherically induced limitations, in optical alignment and direction observations of high accuracy. In the dispersometer we are using the dual-wavelength method for dispersive air to obtain refraction compensated angle measurements, the detrimental impact of atmospheric turbulence notwithstanding. The principle of the dual-wavelength method utilizes atmospherical dispersion, i.e. the wavelength dependence of the refractive index. The difference angle between two light beams of different wavelengths, which is called the dispersion angle Δβ, is to first approximation proportional to the refraction angle: β IR ν(β blue - β IR ) = ν Δβ, this equation implies that the dispersion angle has to be measured at least 42 times more accurate than the desired accuracy of the refraction angle for the wavelengths used in the present dispersometer. This required accuracy constitutes one major difficulty for the instrumental performance in applying the dispersion effect. However, the dual-wavelength method can only be successfully used in an optimized transmitter-receiver combination. Beyond the above mentioned resolution requirement for the detector, major difficulties in instrumental realization arise in the availability of a suitable dual-wavelength laser light source, laser light modulation with a very high extinction ratio and coaxial emittance of mono-mode radiation at both wavelengths. Therefore, this paper focuses on the solutions of the dual-wavelength transmitter introducing a new hardware approach and a complete re-design of the in [1] proposed conception of the dual

  13. High-accuracy user identification using EEG biometrics.

    Science.gov (United States)

    Koike-Akino, Toshiaki; Mahajan, Ruhi; Marks, Tim K; Ye Wang; Watanabe, Shinji; Tuzel, Oncel; Orlik, Philip

    2016-08-01

    We analyze brain waves acquired through a consumer-grade EEG device to investigate its capabilities for user identification and authentication. First, we show the statistical significance of the P300 component in event-related potential (ERP) data from 14-channel EEGs across 25 subjects. We then apply a variety of machine learning techniques, comparing the user identification performance of various different combinations of a dimensionality reduction technique followed by a classification algorithm. Experimental results show that an identification accuracy of 72% can be achieved using only a single 800 ms ERP epoch. In addition, we demonstrate that the user identification accuracy can be significantly improved to more than 96.7% by joint classification of multiple epochs.

  14. High Accuracy Attitude Control System Design for Satellite with Flexible Appendages

    Directory of Open Access Journals (Sweden)

    Wenya Zhou

    2014-01-01

    Full Text Available In order to realize the high accuracy attitude control of satellite with flexible appendages, attitude control system consisting of the controller and structural filter was designed. When the low order vibration frequency of flexible appendages is approximating the bandwidth of attitude control system, the vibration signal will enter the control system through measurement device to bring impact on the accuracy or even the stability. In order to reduce the impact of vibration of appendages on the attitude control system, the structural filter is designed in terms of rejecting the vibration of flexible appendages. Considering the potential problem of in-orbit frequency variation of the flexible appendages, the design method for the adaptive notch filter is proposed based on the in-orbit identification technology. Finally, the simulation results are given to demonstrate the feasibility and effectiveness of the proposed design techniques.

  15. UCAC and URAT: Optical Astrometric Catalog Observing Programs

    Science.gov (United States)

    2010-09-21

    12 100 K 1.0 1997 Tycho-2 G/S yes <= 12 2.5 M 10..100 2000 UCAC G yes 8..16 100 M 20.. 70 2004+ 2MASS G no IR...UCAC3 G yes 8..16 100 M 20.. 70 2009 first CCD survey 2MASS G no IR 500 M 90 2003 1 epoch USNO-B G yes 12..21 1000 M 200 2003 Schmidt plates PanSTARRS G

  16. Technics study on high accuracy crush dressing and sharpening of diamond grinding wheel

    Science.gov (United States)

    Jia, Yunhai; Lu, Xuejun; Li, Jiangang; Zhu, Lixin; Song, Yingjie

    2011-05-01

    Mechanical grinding of artificial diamond grinding wheel was traditional wheel dressing process. The rotate speed and infeed depth of tool wheel were main technics parameters. The suitable technics parameters of metals-bonded diamond grinding wheel and resin-bonded diamond grinding wheel high accuracy crush dressing were obtained by a mount of experiment in super-hard material wheel dressing grind machine and by analysis of grinding force. In the same time, the effect of machine sharpening and sprinkle granule sharpening was contrasted. These analyses and lots of experiments had extent instruction significance to artificial diamond grinding wheel accuracy crush dressing.

  17. THE 2012 HUBBLE ULTRA DEEP FIELD (UDF12): OBSERVATIONAL OVERVIEW

    Energy Technology Data Exchange (ETDEWEB)

    Koekemoer, Anton M. [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Ellis, Richard S.; Schenker, Matthew A. [Department of Astrophysics, California Institute of Technology, MS 249-17, Pasadena, CA 91125 (United States); McLure, Ross J.; Dunlop, James S.; Bowler, Rebecca A. A.; Rogers, Alexander B.; Curtis-Lake, Emma; Cirasuolo, Michele; Wild, V.; Targett, T. [Institute for Astronomy, University of Edinburgh, Royal Observatory, Edinburgh EH9 3HJ (United Kingdom); Robertson, Brant E.; Schneider, Evan; Stark, Daniel P. [Department of Astronomy and Steward Observatory, University of Arizona, Tucson, AZ 85721 (United States); Ono, Yoshiaki; Ouchi, Masami [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa City, Chiba 277-8582 (Japan); Charlot, Stephane [UPMC-CNRS, UMR7095, Institut d' Astrophysique de Paris, F-75014, Paris (France); Furlanetto, Steven R. [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States)

    2013-11-01

    We present the 2012 Hubble Ultra Deep Field campaign (UDF12), a large 128 orbit Cycle 19 Hubble Space Telescope program aimed at extending previous Wide Field Camera 3 (WFC3)/IR observations of the UDF by quadrupling the exposure time in the F105W filter, imaging in an additional F140W filter, and extending the F160W exposure time by 50%, as well as adding an extremely deep parallel field with the Advanced Camera for Surveys (ACS) in the F814W filter with a total exposure time of 128 orbits. The principal scientific goal of this project is to determine whether galaxies reionized the universe; our observations are designed to provide a robust determination of the star formation density at z ∼> 8, improve measurements of the ultraviolet continuum slope at z ∼ 7-8, facilitate the construction of new samples of z ∼ 9-10 candidates, and enable the detection of sources up to z ∼ 12. For this project we committed to combining these and other WFC3/IR imaging observations of the UDF area into a single homogeneous dataset to provide the deepest near-infrared observations of the sky. In this paper we present the observational overview of the project and describe the procedures used in reducing the data as well as the final products that were produced. We present the details of several special procedures that we implemented to correct calibration issues in the data for both the WFC3/IR observations of the main UDF field and our deep 128 orbit ACS/WFC F814W parallel field image, including treatment for persistence, correction for time-variable sky backgrounds, and astrometric alignment to an accuracy of a few milliarcseconds. We release the full, combined mosaics comprising a single, unified set of mosaics of the UDF, providing the deepest near-infrared blank-field view of the universe currently achievable, reaching magnitudes as deep as AB ∼ 30 mag in the near-infrared, and yielding a legacy dataset on this field.

  18. THE 2012 HUBBLE ULTRA DEEP FIELD (UDF12): OBSERVATIONAL OVERVIEW

    International Nuclear Information System (INIS)

    Koekemoer, Anton M.; Ellis, Richard S.; Schenker, Matthew A.; McLure, Ross J.; Dunlop, James S.; Bowler, Rebecca A. A.; Rogers, Alexander B.; Curtis-Lake, Emma; Cirasuolo, Michele; Wild, V.; Targett, T.; Robertson, Brant E.; Schneider, Evan; Stark, Daniel P.; Ono, Yoshiaki; Ouchi, Masami; Charlot, Stephane; Furlanetto, Steven R.

    2013-01-01

    We present the 2012 Hubble Ultra Deep Field campaign (UDF12), a large 128 orbit Cycle 19 Hubble Space Telescope program aimed at extending previous Wide Field Camera 3 (WFC3)/IR observations of the UDF by quadrupling the exposure time in the F105W filter, imaging in an additional F140W filter, and extending the F160W exposure time by 50%, as well as adding an extremely deep parallel field with the Advanced Camera for Surveys (ACS) in the F814W filter with a total exposure time of 128 orbits. The principal scientific goal of this project is to determine whether galaxies reionized the universe; our observations are designed to provide a robust determination of the star formation density at z ∼> 8, improve measurements of the ultraviolet continuum slope at z ∼ 7-8, facilitate the construction of new samples of z ∼ 9-10 candidates, and enable the detection of sources up to z ∼ 12. For this project we committed to combining these and other WFC3/IR imaging observations of the UDF area into a single homogeneous dataset to provide the deepest near-infrared observations of the sky. In this paper we present the observational overview of the project and describe the procedures used in reducing the data as well as the final products that were produced. We present the details of several special procedures that we implemented to correct calibration issues in the data for both the WFC3/IR observations of the main UDF field and our deep 128 orbit ACS/WFC F814W parallel field image, including treatment for persistence, correction for time-variable sky backgrounds, and astrometric alignment to an accuracy of a few milliarcseconds. We release the full, combined mosaics comprising a single, unified set of mosaics of the UDF, providing the deepest near-infrared blank-field view of the universe currently achievable, reaching magnitudes as deep as AB ∼ 30 mag in the near-infrared, and yielding a legacy dataset on this field

  19. High accuracy subwavelength distance measurements: A variable-angle standing-wave total-internal-reflection optical microscope

    International Nuclear Information System (INIS)

    Haynie, A.; Min, T.-J.; Luan, L.; Mu, W.; Ketterson, J. B.

    2009-01-01

    We describe an extension of the total-internal-reflection microscopy technique that permits direct in-plane distance measurements with high accuracy (<10 nm) over a wide range of separations. This high position accuracy arises from the creation of a standing evanescent wave and the ability to sweep the nodal positions (intensity minima of the standing wave) in a controlled manner via both the incident angle and the relative phase of the incoming laser beams. Some control over the vertical resolution is available through the ability to scan the incoming angle and with it the evanescent penetration depth.

  20. Serpens X-1 observed by INTEGRAL

    DEFF Research Database (Denmark)

    Masetti, N.; Foschini, L.; Palazzi, E.

    2004-01-01

    -1 has been clearly detected up to 30 keV with unprecedented positional accuracy for high-energy emission. The 20-30 keV light curve showed substantial variability during the observation. Comparison with previous observations indicates that the source was in its high ("banana") state and displayed...

  1. Treatment accuracy of hypofractionated spine and other highly conformal IMRT treatments

    International Nuclear Information System (INIS)

    Sutherland, B.; Hanlon, P.; Charles, P.

    2011-01-01

    Full text: Spinal cord metastases pose difficult challenges for radiation treatment due to tight dose constraints and a concave PTY. This project aimed to thoroughly test the treatment accuracy of the Eclipse Treatment Planning System (TPS) for highly modulated IMRT treatments, in particular of the thoracic spine, using an Elekta Synergy Linear Accelerator. The increased understanding obtained through different quality assurance techniques allowed recommendations to be made for treatment site commissioning with improved accuracy at the Princess Alexandra Hospital (PAH). Three thoracic spine IMRT plans at the PAH were used for data collection. Complex phantom models were built using CT data, and fields simulated using Monte Carlo modelling. The simulated dose distributions were compared with the TPS using gamma analysis and DYH comparison. High resolution QA was done for all fields using the MatriXX ion chamber array, MapCHECK2 diode array shifted, and the EPlD to determine a procedure for commissioning new treatment sites. Basic spine simulations found the TPS overestimated absorbed dose to bone, however within spinal cord there was good agreement. High resolution QA found the average gamma pass rate of the fields to be 99.1 % for MatriXX, 96.5% for MapCHECK2 shifted and 97.7% for EPlD. Preliminary results indicate agreement between the TPS and delivered dose distributions higher than previously believed for the investigated IMRT plans. The poor resolution of the MatriXX, and normalisation issues with MapCHECK2 leads to probable recommendation of EPlD for future IMRT commissioning due to the high resolution and minimal setup required.

  2. Astrometric observations of Saturn's satellites from McDonald Observatory, 1972. [using reference stars

    Science.gov (United States)

    Abbot, R. I.; Mulholland, J. D.; Shelus, P. J.

    1974-01-01

    Observations of Saturn's satellites were reduced by means of secondary reference stars obtained by reduction of Palomar Sky Survey (PSS) plates. This involved the use of 39 SAO stars and plate overlap technique to determine the coordinates of 59 fainter stars in the satellite field. Fourteen plate constants were determined for each of the two PSS plates. Comparison of two plate measurement and reduction techniques on the satellite measurements demonstrate the existence of a serious background gradient effect and the utility of microdensitometry to eliminate this error source in positional determinations of close satellites.

  3. Accuracy improvement techniques in Precise Point Positioning method using multiple GNSS constellations

    Science.gov (United States)

    Vasileios Psychas, Dimitrios; Delikaraoglou, Demitris

    2016-04-01

    The future Global Navigation Satellite Systems (GNSS), including modernized GPS, GLONASS, Galileo and BeiDou, offer three or more signal carriers for civilian use and much more redundant observables. The additional frequencies can significantly improve the capabilities of the traditional geodetic techniques based on GPS signals at two frequencies, especially with regard to the availability, accuracy, interoperability and integrity of high-precision GNSS applications. Furthermore, highly redundant measurements can allow for robust simultaneous estimation of static or mobile user states including more parameters such as real-time tropospheric biases and more reliable ambiguity resolution estimates. This paper presents an investigation and analysis of accuracy improvement techniques in the Precise Point Positioning (PPP) method using signals from the fully operational (GPS and GLONASS), as well as the emerging (Galileo and BeiDou) GNSS systems. The main aim was to determine the improvement in both the positioning accuracy achieved and the time convergence it takes to achieve geodetic-level (10 cm or less) accuracy. To this end, freely available observation data from the recent Multi-GNSS Experiment (MGEX) of the International GNSS Service, as well as the open source program RTKLIB were used. Following a brief background of the PPP technique and the scope of MGEX, the paper outlines the various observational scenarios that were used in order to test various data processing aspects of PPP solutions with multi-frequency, multi-constellation GNSS systems. Results from the processing of multi-GNSS observation data from selected permanent MGEX stations are presented and useful conclusions and recommendations for further research are drawn. As shown, data fusion from GPS, GLONASS, Galileo and BeiDou systems is becoming increasingly significant nowadays resulting in a position accuracy increase (mostly in the less favorable East direction) and a large reduction of convergence

  4. Weather and atmosphere observation with the ATOM all-sky camera

    Directory of Open Access Journals (Sweden)

    Jankowsky Felix

    2015-01-01

    Full Text Available The Automatic Telescope for Optical Monitoring (ATOM for H.E.S.S. is an 75 cm optical telescope which operates fully automated. As there is no observer present during observation, an auxiliary all-sky camera serves as weather monitoring system. This device takes an all-sky image of the whole sky every three minutes. The gathered data then undergoes live-analysis by performing astrometric comparison with a theoretical night sky model, interpreting the absence of stars as cloud coverage. The sky monitor also serves as tool for a meteorological analysis of the observation site of the the upcoming Cherenkov Telescope Array. This overview covers design and benefits of the all-sky camera and additionally gives an introduction into current efforts to integrate the device into the atmosphere analysis programme of H.E.S.S.

  5. High accuracy of family history of melanoma in Danish melanoma cases

    DEFF Research Database (Denmark)

    Wadt, Karin A W; Drzewiecki, Krzysztof T; Gerdes, Anne-Marie

    2015-01-01

    The incidence of melanoma in Denmark has immensely increased over the last 10 years making Denmark a high risk country for melanoma. In the last two decades multiple public campaigns have sought to increase the awareness of melanoma. Family history of melanoma is a known major risk factor...... but previous studies have shown that self-reported family history of melanoma is highly inaccurate. These studies are 15 years old and we wanted to examine if a higher awareness of melanoma has increased the accuracy of self-reported family history of melanoma. We examined the family history of 181 melanoma...

  6. Mutual Events in the Uranian satellite system in 2007

    Science.gov (United States)

    Arlot, J. E.

    2008-09-01

    The equinox time on the giant planets When the Sun crosses the equatorial plane of a giant planet, it is the equinox time occurring every half orbit of the planet, i.e. every 6 years for Jupiter, 14 years for Saturn, 42 years for Uranus and 82 years for Neptune. Except Neptune, each planet have several major satellites orbiting in the equatorial plane, then, during the equinox time, the satellites will eclipse each other mutually. Since the Earth follows the Sun, during the equinox time, a terrestrial observer will see each satellite occulting each other during the same period. These events may be observed with photometric receivers since the light from the satellites will decrease during the events. The light curve will provide information on the geometric configuration of the the satellites at the time of the event with an accuracy of a few kilometers, not depending on the distance of the satellite system. Then, we are able to get an astrometric observation with an accuracy several times better than using direct imaging for positions. Equinox on Uranus in 2007 In 2007, it was equinox time on Uranus. The Sun crossed the equatorial plane of Uranus on December 6, 2007. Since the opposition Uranus-Sun was at the end of August 2007, observations were performed from May to December 2007. Since the declination of Uranus was between -5 and -6 degrees, observations were better to make in the southern hemisphere. However, some difficulties had to be solved: the faintness of the satellites (magnitude between 14 and 16), the brightness of the planet (magnitude 5) making difficult the photometric observation of the satellites. The used of K' filter associated to a large telescope allows to increase the number of observable events. Dynamics of the Uranian satellites One of the goals of the observations was to evaluate the accuracy of the current dynamical models of the motion of the satellites. This knowledge is important for several reasons: most of time the Uranian system is

  7. High-accuracy Subdaily ERPs from the IGS

    Science.gov (United States)

    Ray, J. R.; Griffiths, J.

    2012-04-01

    Since November 2000 the International GNSS Service (IGS) has published Ultra-rapid (IGU) products for near real-time (RT) and true real-time applications. They include satellite orbits and clocks, as well as Earth rotation parameters (ERPs) for a sliding 48-hr period. The first day of each update is based on the most recent GPS and GLONASS observational data from the IGS hourly tracking network. At the time of release, these observed products have an initial latency of 3 hr. The second day of each update consists of predictions. So the predictions between about 3 and 9 hr into the second half are relevant for true RT uses. Originally updated twice daily, the IGU products since April 2004 have been issued every 6 hr, at 3, 9, 15, and 21 UTC. Up to seven Analysis Centers (ACs) contribute to the IGU combinations. Two sets of ERPs are published with each IGU update, observed values at the middle epoch of the first half and predicted values at the middle epoch of the second half. The latency of the near RT ERPs is 15 hr while the predicted ERPs, based on projections of each AC's most recent determinations, are issued 9 hr ahead of their reference epoch. While IGU ERPs are issued every 6 hr, each set represents an integrated estimate over the surrounding 24 hr. So successive values are temporally correlated with about 75% of the data being common; this fact should be taken into account in user assimilations. To evaluate the accuracy of these near RT and predicted ERPs, they have been compared to the IGS Final ERPs, available about 11 to 17 d after data collection. The IGU products improved dramatically in the earlier years but since about 2008.0 the performance has been stable and excellent. During the last three years, RMS differences for the observed IGU ERPs have been about 0.036 mas and 0.0101 ms for each polar motion component and LOD respectively. (The internal precision of the reference IGS ERPs over the same period is about 0.016 mas for polar motion and 0

  8. PROBING THE GALACTIC POTENTIAL WITH NEXT-GENERATION OBSERVATIONS OF DISK STARS

    International Nuclear Information System (INIS)

    Sumi, T.; Johnston, K. V.; Tremaine, S.; Spergel, D. N.; Majewski, S. R.

    2009-01-01

    Our current knowledge of the rotation curve of the Milky Way is remarkably poor compared to other galaxies, limited by the combined effects of extinction and the lack of large samples of stars with good distance estimates and proper motions. Near-future surveys promise a dramatic improvement in the number and precision of astrometric, photometric, and spectroscopic measurements of stars in the Milky Way's disk. We examine the impact of such surveys on our understanding of the Galaxy by 'observing' particle realizations of nonaxisymmetric disk distributions orbiting in an axisymmetric halo with appropriate errors and then attempting to recover the underlying potential using a Markov Chain Monte Carlo approach. We demonstrate that the azimuthally averaged gravitational force field in the Galactic plane-and hence, to a lesser extent, the Galactic mass distribution-can be tightly constrained over a large range of radii using a variety of types of surveys so long as the error distribution of the measurements of the parallax, proper motion, and radial velocity are well understood and the disk is surveyed globally. One advantage of our method is that the target stars can be selected nonrandomly in real or apparent-magnitude space to ensure just such a global sample without biasing the results. Assuming that we can always measure the line-of-sight velocity of a star with at least 1 km s -1 precision, we demonstrate that the force field can be determined to better than ∼1% for Galactocentric radii in the range R = 4-20 kpc using either: (1) small samples (a few hundred stars) with very accurate trigonometric parallaxes and good proper-motion measurements (uncertainties δ p,tri ∼ μ ∼ -1 respectively); (2) modest samples (∼1000 stars) with good indirect parallax estimates (e.g., uncertainty in photometric parallax δ p,phot ∼ 10%-20%) and good proper-motion measurements (δ μ ∼ 100 μas yr -1 ); or (3) large samples (∼10 4 stars) with good indirect parallax

  9. High-Accuracy Elevation Data at Large Scales from Airborne Single-Pass SAR Interferometry

    Directory of Open Access Journals (Sweden)

    Guy Jean-Pierre Schumann

    2016-01-01

    Full Text Available Digital elevation models (DEMs are essential data sets for disaster risk management and humanitarian relief services as well as many environmental process models. At present, on the hand, globally available DEMs only meet the basic requirements and for many services and modeling studies are not of high enough spatial resolution and lack accuracy in the vertical. On the other hand, LiDAR-DEMs are of very high spatial resolution and great vertical accuracy but acquisition operations can be very costly for spatial scales larger than a couple of hundred square km and also have severe limitations in wetland areas and under cloudy and rainy conditions. The ideal situation would thus be to have a DEM technology that allows larger spatial coverage than LiDAR but without compromising resolution and vertical accuracy and still performing under some adverse weather conditions and at a reasonable cost. In this paper, we present a novel single pass In-SAR technology for airborne vehicles that is cost-effective and can generate DEMs with a vertical error of around 0.3 m for an average spatial resolution of 3 m. To demonstrate this capability, we compare a sample single-pass In-SAR Ka-band DEM of the California Central Valley from the NASA/JPL airborne GLISTIN-A to a high-resolution LiDAR DEM. We also perform a simple sensitivity analysis to floodplain inundation. Based on the findings of our analysis, we argue that this type of technology can and should be used to replace large regions of globally available lower resolution DEMs, particularly in coastal, delta and floodplain areas where a high number of assets, habitats and lives are at risk from natural disasters. We conclude with a discussion on requirements, advantages and caveats in terms of instrument and data processing.

  10. In-flight Quality and Accuracy of Attitude Measurements from the CHAMP Advanced Stellar Compass

    DEFF Research Database (Denmark)

    Jørgensen, Peter Siegbjørn; Jørgensen, John Leif; Denver, Troelz

    2005-01-01

    The German geo-observations satellite CHAMP carries highly accurate vector instruments. The orientation of these relative to the inertial reference frame is obtained using star trackers. These advanced stellar compasses (ASC) are fully autonomous units, which provide, in real time, the absolute...... attitude with accuracy in the arc second range. In order to investigate the in-flight accuracy of the ASC, the terminology to characterize noise and biases is introduced. Relative instrument accuracy (RIA) and absolute instrument accuracy (AIA) can in principle be determined in-flight. However problems...

  11. Accuracy Assessment of Different Digital Surface Models

    Directory of Open Access Journals (Sweden)

    Ugur Alganci

    2018-03-01

    Full Text Available Digital elevation models (DEMs, which can occur in the form of digital surface models (DSMs or digital terrain models (DTMs, are widely used as important geospatial information sources for various remote sensing applications, including the precise orthorectification of high-resolution satellite images, 3D spatial analyses, multi-criteria decision support systems, and deformation monitoring. The accuracy of DEMs has direct impacts on specific calculations and process chains; therefore, it is important to select the most appropriate DEM by considering the aim, accuracy requirement, and scale of each study. In this research, DSMs obtained from a variety of satellite sensors were compared to analyze their accuracy and performance. For this purpose, freely available Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER 30 m, Shuttle Radar Topography Mission (SRTM 30 m, and Advanced Land Observing Satellite (ALOS 30 m resolution DSM data were obtained. Additionally, 3 m and 1 m resolution DSMs were produced from tri-stereo images from the SPOT 6 and Pleiades high-resolution (PHR 1A satellites, respectively. Elevation reference data provided by the General Command of Mapping, the national mapping agency of Turkey—produced from 30 cm spatial resolution stereo aerial photos, with a 5 m grid spacing and ±3 m or better overall vertical accuracy at the 90% confidence interval (CI—were used to perform accuracy assessments. Gross errors and water surfaces were removed from the reference DSM. The relative accuracies of the different DSMs were tested using a different number of checkpoints determined by different methods. In the first method, 25 checkpoints were selected from bare lands to evaluate the accuracies of the DSMs on terrain surfaces. In the second method, 1000 randomly selected checkpoints were used to evaluate the methods’ accuracies for the whole study area. In addition to the control point approach, vertical cross

  12. Photographical observations of planet satellite carried out in MAO NASU in 1961- 1990

    Science.gov (United States)

    Izhakevich, E. M.; Kulik, I. V.; Shatohina, S. V.

    2001-10-01

    Intensive photographic observations of the Solar System body were made during the 1961-1990 at Golosiiv. More than 300 photographic plates were obtained for this period. The images of the satellites of Jupiter, Saturn, Uran are available in these plates. The photographic observations of the natural moons were acquired in 1986-1990 at Majdanak. All accumulated plates were remeasured and astrometric positions all available moons were obtained in the ACT and Tyho-2 systems. We present about 900 positions of eight Saturian satellites, Uranium moons Ariel, Umbriel, Oberon, Titanium and Neptunium moon Triton. The differences calculated and theoretical positions were obtained. Mean rms errors of the (O-C) are in the range 0.2-0.3 arcsec.

  13. High-accuracy drilling with an image guided light weight robot: autonomous versus intuitive feed control.

    Science.gov (United States)

    Tauscher, Sebastian; Fuchs, Alexander; Baier, Fabian; Kahrs, Lüder A; Ortmaier, Tobias

    2017-10-01

    Assistance of robotic systems in the operating room promises higher accuracy and, hence, demanding surgical interventions become realisable (e.g. the direct cochlear access). Additionally, an intuitive user interface is crucial for the use of robots in surgery. Torque sensors in the joints can be employed for intuitive interaction concepts. Regarding the accuracy, they lead to a lower structural stiffness and, thus, to an additional error source. The aim of this contribution is to examine, if an accuracy needed for demanding interventions can be achieved by such a system or not. Feasible accuracy results of the robot-assisted process depend on each work-flow step. This work focuses on the determination of the tool coordinate frame. A method for drill axis definition is implemented and analysed. Furthermore, a concept of admittance feed control is developed. This allows the user to control feeding along the planned path by applying a force to the robots structure. The accuracy is researched by drilling experiments with a PMMA phantom and artificial bone blocks. The described drill axis estimation process results in a high angular repeatability ([Formula: see text]). In the first set of drilling results, an accuracy of [Formula: see text] at entrance and [Formula: see text] at target point excluding imaging was achieved. With admittance feed control an accuracy of [Formula: see text] at target point was realised. In a third set twelve holes were drilled in artificial temporal bone phantoms including imaging. In this set-up an error of [Formula: see text] and [Formula: see text] was achieved. The results of conducted experiments show that accuracy requirements for demanding procedures such as the direct cochlear access can be fulfilled with compliant systems. Furthermore, it was shown that with the presented admittance feed control an accuracy of less then [Formula: see text] is achievable.

  14. Astrometry and Geostationary Satellites in Venezuela

    Science.gov (United States)

    Lacruz, E.; Abad, C.

    2015-10-01

    We present the current status and the first results of the astrometric project CIDA - ABAE for tracking geo-stationary satellites. This project aims to determine a preliminary orbit for the Venezuelan satellite VENESAT-1, using astrometric positions obtained from an optical telescope. The results presented here are based on observations from the Luepa space tracking ground station in Venezuela, which were processed using astrometric procedures.

  15. The first astronomical hypothesis based on cinematographical observations: Costa Lobo's 1912 evidence for polar flattening of the moon

    Science.gov (United States)

    Bonifácio, Vitor; Malaquias, Isabel; Fernandes, João

    2010-07-01

    Acceptance by the scientific community of results obtained with new technology can be a complex process. A particularly good example is provided by the unexpected hypothesis raised by Francisco Miranda da Costa Lobo upon examination of the cinematographic film obtained during the solar eclipse of 17 April 1912. Contrary to contemporary practice this eclipse was eagerly awaited in view of its astrometrical rather than astrophysical scientific interest. The observation of this hybrid eclipse provided, in theory, a good opportunity to improve several astrometric parameters, and in particular the Moon's apparent diameter. Observations were performed from Portugal to Russia and, for the first time, movie cameras were widely deployed to register astronomical phenomena. Upon analysing the film obtained at Ovar (Portugal), Costa Lobo realised that during totality Baily's Beads were not symmetrically distributed around the Moon. As an explanation and opposing current belief he proposed a lunar flattening in the range 1/1156 to 1/380. Initially other eclipse observers supported Costa Lobo's claim. In particular, Father Willaert obtained a flattening value of 1/2050 from his cinematographic film taken at Namur (Belgium). However, these results were quickly disregarded by the international astronomical community which favoured an explanation based upon the irregularities of the lunar profile. In this paper we recall the characteristics of the 17 April 1912 eclipse and the cinematographic observations, and review the results obtained. We conclude that the lack of attention paid by the astronomical community to the new cinematographical results and Camille Flammarion's superficial analysis of the data were instrumental in the rejection of Costa Lobo's hypothesis.

  16. High accuracy of family history of melanoma in Danish melanoma cases.

    Science.gov (United States)

    Wadt, Karin A W; Drzewiecki, Krzysztof T; Gerdes, Anne-Marie

    2015-12-01

    The incidence of melanoma in Denmark has immensely increased over the last 10 years making Denmark a high risk country for melanoma. In the last two decades multiple public campaigns have sought to increase the awareness of melanoma. Family history of melanoma is a known major risk factor but previous studies have shown that self-reported family history of melanoma is highly inaccurate. These studies are 15 years old and we wanted to examine if a higher awareness of melanoma has increased the accuracy of self-reported family history of melanoma. We examined the family history of 181 melanoma probands who reported 199 cases of melanoma in relatives, of which 135 cases where in first degree relatives. We confirmed the diagnosis of melanoma in 77% of all relatives, and in 83% of first degree relatives. In 181 probands we validated the negative family history of melanoma in 748 first degree relatives and found only 1 case of melanoma which was not reported in a 3 case melanoma family. Melanoma patients in Denmark report family history of melanoma in first and second degree relatives with a high level of accuracy with a true positive predictive value between 77 and 87%. In 99% of probands reporting a negative family history of melanoma in first degree relatives this information is correct. In clinical practice we recommend that melanoma diagnosis in relatives should be verified if possible, but even unverified reported melanoma cases in relatives should be included in the indication of genetic testing and assessment of melanoma risk in the family.

  17. Fission product model for BWR analysis with improved accuracy in high burnup

    International Nuclear Information System (INIS)

    Ikehara, Tadashi; Yamamoto, Munenari; Ando, Yoshihira

    1998-01-01

    A new fission product (FP) chain model has been studied to be used in a BWR lattice calculation. In attempting to establish the model, two requirements, i.e. the accuracy in predicting burnup reactivity and the easiness in practical application, are simultaneously considered. The resultant FP model consists of 81 explicit FP nuclides and two lumped pseudo nuclides having the absorption cross sections independent of burnup history and fuel composition. For the verification, extensive numerical tests covering over a wide range of operational conditions and fuel compositions have been carried out. The results indicate that the estimated errors in burnup reactivity are within 0.1%Δk for exposures up to 100GWd/t. It is concluded that the present model can offer a high degree of accuracy for FP representation in BWR lattice calculation. (author)

  18. DIRECT GEOREFERENCING : A NEW STANDARD IN PHOTOGRAMMETRY FOR HIGH ACCURACY MAPPING

    Directory of Open Access Journals (Sweden)

    A. Rizaldy

    2012-07-01

    Full Text Available Direct georeferencing is a new method in photogrammetry, especially in the digital camera era. Theoretically, this method does not require ground control points (GCP and the Aerial Triangulation (AT, to process aerial photography into ground coordinates. Compared with the old method, this method has three main advantages: faster data processing, simple workflow and less expensive project, at the same accuracy. Direct georeferencing using two devices, GPS and IMU. GPS recording the camera coordinates (X, Y, Z, and IMU recording the camera orientation (omega, phi, kappa. Both parameters merged into Exterior Orientation (EO parameter. This parameters required for next steps in the photogrammetric projects, such as stereocompilation, DSM generation, orthorectification and mosaic. Accuracy of this method was tested on topographic map project in Medan, Indonesia. Large-format digital camera Ultracam X from Vexcel is used, while the GPS / IMU is IGI AeroControl. 19 Independent Check Point (ICP were used to determine the accuracy. Horizontal accuracy is 0.356 meters and vertical accuracy is 0.483 meters. Data with this accuracy can be used for 1:2.500 map scale project.

  19. Recovery of Bennu's orientation for the OSIRIS-REx mission: implications for the spin state accuracy and geolocation errors

    Science.gov (United States)

    Mazarico, Erwan; Rowlands, David D.; Sabaka, Terence J.; Getzandanner, Kenneth M.; Rubincam, David P.; Nicholas, Joseph B.; Moreau, Michael C.

    2017-10-01

    The goal of the OSIRIS-REx mission is to return a sample of asteroid material from near-Earth asteroid (101955) Bennu. The role of the navigation and flight dynamics team is critical for the spacecraft to execute a precisely planned sampling maneuver over a specifically selected landing site. In particular, the orientation of Bennu needs to be recovered with good accuracy during orbital operations to contribute as small an error as possible to the landing error budget. Although Bennu is well characterized from Earth-based radar observations, its orientation dynamics are not sufficiently known to exclude the presence of a small wobble. To better understand this contingency and evaluate how well the orientation can be recovered in the presence of a large 1° wobble, we conduct a comprehensive simulation with the NASA GSFC GEODYN orbit determination and geodetic parameter estimation software. We describe the dynamic orientation modeling implemented in GEODYN in support of OSIRIS-REx operations and show how both altimetry and imagery data can be used as either undifferenced (landmark, direct altimetry) or differenced (image crossover, altimetry crossover) measurements. We find that these two different types of data contribute differently to the recovery of instrument pointing or planetary orientation. When upweighted, the absolute measurements help reduce the geolocation errors, despite poorer astrometric (inertial) performance. We find that with no wobble present, all the geolocation requirements are met. While the presence of a large wobble is detrimental, the recovery is still reliable thanks to the combined use of altimetry and imagery data.

  20. High-accuracy identification and bioinformatic analysis of in vivo protein phosphorylation sites in yeast

    DEFF Research Database (Denmark)

    Gnad, Florian; de Godoy, Lyris M F; Cox, Jürgen

    2009-01-01

    Protein phosphorylation is a fundamental regulatory mechanism that affects many cell signaling processes. Using high-accuracy MS and stable isotope labeling in cell culture-labeling, we provide a global view of the Saccharomyces cerevisiae phosphoproteome, containing 3620 phosphorylation sites ma...

  1. High Accuracy Mass Measurement of the Dripline Nuclides $^{12,14}$Be

    CERN Multimedia

    2002-01-01

    State-of-the art, three-body nuclear models that describe halo nuclides require the binding energy of the halo neutron(s) as a critical input parameter. In the case of $^{14}$Be, the uncertainty of this quantity is currently far too large (130 keV), inhibiting efforts at detailed theoretical description. A high accuracy, direct mass deterlnination of $^{14}$Be (as well as $^{12}$Be to obtain the two-neutron separation energy) is therefore required. The measurement can be performed with the MISTRAL spectrometer, which is presently the only possible solution due to required accuracy (10 keV) and short half-life (4.5 ms). Having achieved a 5 keV uncertainty for the mass of $^{11}$Li (8.6 ms), MISTRAL has proved the feasibility of such measurements. Since the current ISOLDE production rate of $^{14}$Be is only about 10/s, the installation of a beam cooler is underway in order to improve MISTRAL transmission. The projected improvement of an order of magnitude (in each transverse direction) will make this measureme...

  2. High Accuracy Beam Current Monitor System for CEBAF'S Experimental Hall A

    International Nuclear Information System (INIS)

    J. Denard; A. Saha; G. Lavessiere

    2001-01-01

    CEBAF accelerator delivers continuous wave (CW) electron beams to three experimental Halls. In Hall A, all experiments require continuous, non-invasive current measurements and a few experiments require an absolute accuracy of 0.2 % in the current range from 1 to 180 (micro)A. A Parametric Current Transformer (PCT), manufactured by Bergoz, has an accurate and stable sensitivity of 4 (micro)A/V but its offset drifts at the muA level over time preclude its direct use for continuous measurements. Two cavity monitors are calibrated against the PCT with at least 50 (micro)A of beam current. The calibration procedure suppresses the error due to PCT's offset drifts by turning the beam on and off, which is invasive to the experiment. One of the goals of the system is to minimize the calibration time without compromising the measurement's accuracy. The linearity of the cavity monitors is a critical parameter for transferring the accurate calibration done at high currents over the whole dynamic range. The method for measuring accurately the linearity is described

  3. Accuracy in HIV Rapid Testing among Laboratory and Non-laboratory Personnel in Zambia: Observations from the National HIV Proficiency Testing System.

    Directory of Open Access Journals (Sweden)

    Sheila Mwangala

    Full Text Available Despite rapid task-shifting and scale-up of HIV testing services in high HIV prevalence countries, studies evaluating accuracy remain limited. This study aimed to assess overall accuracy level and factors associated with accuracy in HIV rapid testing in Zambia.Accuracy was investigated among rural and urban HIV testing sites participating in two annual national HIV proficiency testing (PT exercises conducted in 2009 (n = 282 sites and 2010 (n = 488 sites. Testers included lay counselors, nurses, laboratory personnel and others. PT panels of five dry tube specimens (DTS were issued to testing sites by the national reference laboratory (NRL. Site accuracy level was assessed by comparison of reported results to the expected results. Non-parametric rank tests and multiple linear regression models were used to assess variation in accuracy between PT cycles and between tester groups, and to examine factors associated with accuracy respectively.Overall accuracy level was 93.1% (95% CI: 91.2-94.9 in 2009 and 96.9% (95% CI: 96.1-97.8 in 2010. Differences in accuracy were seen between the tester groups in 2009 with laboratory personnel being more accurate than non-laboratory personnel, while in 2010 no differences were seen. In both PT exercises, lay counselors and nurses had more difficulties interpreting results, with more occurrences of false-negative, false-positive and indeterminate results. Having received the standard HIV rapid testing training and adherence to the national HIV testing algorithm were positively associated with accuracy.The study showed an improvement in tester group and overall accuracy from the first PT exercise to the next. Average number of incorrect test results per 1000 tests performed was reduced from 69 to 31. Further improvement is needed, however, and the national HIV proficiency testing system seems to be an important tool in this regard, which should be continued and needs to be urgently strengthened.

  4. Planning JWST NIRSpec MSA spectroscopy using NIRCam pre-images

    Science.gov (United States)

    Beck, Tracy L.; Ubeda, Leonardo; Kassin, Susan A.; Gilbert, Karoline; Karakla, Diane M.; Reid, I. N.; Blair, William P.; Keyes, Charles D.; Soderblom, D. R.; Peña-Guerrero, Maria A.

    2016-07-01

    The Near-Infrared Spectrograph (NIRSpec) is the work-horse spectrograph at 1-5microns for the James Webb Space Telescope (JWST). A showcase observing mode of NIRSpec is the multi-object spectroscopy with the Micro-Shutter Arrays (MSAs), which consist of a quarter million tiny configurable shutters that are 0. ''20×0. ''46 in size. The NIRSpec MSA shutters can be opened in adjacent rows to create flexible and positionable spectroscopy slits on prime science targets of interest. Because of the very small shutter width, the NIRSpec MSA spectral data quality will benefit significantly from accurate astrometric knowledge of the positions of planned science sources. Images acquired with the Hubble Space Telescope (HST) have the optimal relative astrometric accuracy for planning NIRSpec observations of 5-10 milli-arcseconds (mas). However, some science fields of interest might have no HST images, galactic fields can have moderate proper motions at the 5mas level or greater, and extragalactic images with HST may have inadequate source information at NIRSpec wavelengths beyond 2 microns. Thus, optimal NIRSpec spectroscopy planning may require pre-imaging observations with the Near-Infrared Camera (NIRCam) on JWST to accurately establish source positions for alignment with the NIRSpec MSAs. We describe operational philosophies and programmatic considerations for acquiring JWST NIRCam pre-image observations for NIRSpec MSA spectroscopic planning within the same JWST observing Cycle.

  5. Applying signal-detection theory to the study of observer accuracy and bias in behavioral assessment.

    Science.gov (United States)

    Lerman, Dorothea C; Tetreault, Allison; Hovanetz, Alyson; Bellaci, Emily; Miller, Jonathan; Karp, Hilary; Mahmood, Angela; Strobel, Maggie; Mullen, Shelley; Keyl, Alice; Toupard, Alexis

    2010-01-01

    We evaluated the feasibility and utility of a laboratory model for examining observer accuracy within the framework of signal-detection theory (SDT). Sixty-one individuals collected data on aggression while viewing videotaped segments of simulated teacher-child interactions. The purpose of Experiment 1 was to determine if brief feedback and contingencies for scoring accurately would bias responding reliably. Experiment 2 focused on one variable (specificity of the operational definition) that we hypothesized might decrease the likelihood of bias. The effects of social consequences and information about expected behavior change were examined in Experiment 3. Results indicated that feedback and contingencies reliably biased responding and that the clarity of the definition only moderately affected this outcome.

  6. High accuracy microwave frequency measurement based on single-drive dual-parallel Mach-Zehnder modulator

    DEFF Research Database (Denmark)

    Zhao, Ying; Pang, Xiaodan; Deng, Lei

    2011-01-01

    A novel approach for broadband microwave frequency measurement by employing a single-drive dual-parallel Mach-Zehnder modulator is proposed and experimentally demonstrated. Based on bias manipulations of the modulator, conventional frequency-to-power mapping technique is developed by performing a...... 10−3 relative error. This high accuracy frequency measurement technique is a promising candidate for high-speed electronic warfare and defense applications....

  7. Innovative Technique for High-Accuracy Remote Monitoring of Surface Water

    Science.gov (United States)

    Gisler, A.; Barton-Grimley, R. A.; Thayer, J. P.; Crowley, G.

    2016-12-01

    Lidar (light detection and ranging) provides absolute depth and topographic mapping capability compared to other remote sensing methods, which is useful for mapping rapidly changing environments such as riverine systems and agricultural waterways. Effectiveness of current lidar bathymetric systems is limited by the difficulty in unambiguously identifying backscattered lidar signals from the water surface versus the bottom, limiting their depth resolution to 0.3-0.5 m. Additionally these are large, bulky systems that are constrained to expensive aircraft-mounted platforms and use waveform-processing techniques requiring substantial computation time. These restrictions are prohibitive for many potential users. A novel lidar device has been developed that allows for non-contact measurements of water depth down to 1 cm with an accuracy and precision of shallow to deep water allowing for shoreline charting, measuring water volume, mapping bottom topology, and identifying submerged objects. The scalability of the technique opens up the ability for handheld or UAS-mounted lidar bathymetric systems, which provides for potential applications currently unavailable to the community. The high laser pulse repetition rate allows for very fine horizontal resolution while the photon-counting technique permits real-time depth measurement and object detection. The enhanced measurement capability, portability, scalability, and relatively low-cost creates the opportunity to perform frequent high-accuracy monitoring and measuring of aquatic environments which is crucial for monitoring water resources on fast timescales. Results from recent campaigns measuring water depth in flowing creeks and murky ponds will be presented which demonstrate that the method is not limited by rough water surfaces and can map underwater topology through moderately turbid water.

  8. High resolution solar observations

    International Nuclear Information System (INIS)

    Title, A.

    1985-01-01

    Currently there is a world-wide effort to develop optical technology required for large diffraction limited telescopes that must operate with high optical fluxes. These developments can be used to significantly improve high resolution solar telescopes both on the ground and in space. When looking at the problem of high resolution observations it is essential to keep in mind that a diffraction limited telescope is an interferometer. Even a 30 cm aperture telescope, which is small for high resolution observations, is a big interferometer. Meter class and above diffraction limited telescopes can be expected to be very unforgiving of inattention to details. Unfortunately, even when an earth based telescope has perfect optics there are still problems with the quality of its optical path. The optical path includes not only the interior of the telescope, but also the immediate interface between the telescope and the atmosphere, and finally the atmosphere itself

  9. MULTIWAVELENGTH OBSERVATIONS OF THE REDBACK MILLISECOND PULSAR J1048+2339

    Energy Technology Data Exchange (ETDEWEB)

    Deneva, J. S. [National Research Council, resident at the Naval Research Laboratory, Washington, DC 20375 (United States); Ray, P. S.; Wood, K.; Wolff, M. T. [Naval Research Laboratory, Washington, DC 20375 (United States); Camilo, F.; Halpern, J. P. [Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Cromartie, H. T. [University of Virginia, Charlottesville, VA 22904 (United States); Ferrara, E. [Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Kerr, M. [CSIRO Astronomy and Space Science, Marsfield NSW 2122 (Australia); Ransom, S. M. [National Radio Astronomy Observatory, Charlottesville, VA 22903 (United States); Chambers, K. C.; Magnier, E. A. [Institute for Astronomy, University of Hawaii, Honolulu, HI 96822 (United States)

    2016-06-01

    We report on radio timing and multiwavelength observations of the 4.66 ms redback pulsar J1048+2339, which was discovered in an Arecibo search targeting the Fermi -Large Area Telescope source 3FGL J1048.6+2338. Two years of timing allowed us to derive precise astrometric and orbital parameters for the pulsar. PSR J1048+2339 is in a 6 hr binary and exhibits radio eclipses over half the orbital period and rapid orbital period variations. The companion has a minimum mass of 0.3 M {sub ⊙}, and we have identified a V ∼ 20 variable optical counterpart in data from several surveys. The phasing of its ∼1 mag modulation at the orbital period suggests highly efficient and asymmetric heating by the pulsar wind, which may be due to an intrabinary shock that is distorted near the companion, or to the companion’s magnetic field channeling the pulsar wind to specific locations on its surface. We also present gamma-ray spectral analysis of the source and preliminary results from searches for gamma-ray pulsations using the radio ephemeris.

  10. A generalized polynomial chaos based ensemble Kalman filter with high accuracy

    International Nuclear Information System (INIS)

    Li Jia; Xiu Dongbin

    2009-01-01

    As one of the most adopted sequential data assimilation methods in many areas, especially those involving complex nonlinear dynamics, the ensemble Kalman filter (EnKF) has been under extensive investigation regarding its properties and efficiency. Compared to other variants of the Kalman filter (KF), EnKF is straightforward to implement, as it employs random ensembles to represent solution states. This, however, introduces sampling errors that affect the accuracy of EnKF in a negative manner. Though sampling errors can be easily reduced by using a large number of samples, in practice this is undesirable as each ensemble member is a solution of the system of state equations and can be time consuming to compute for large-scale problems. In this paper we present an efficient EnKF implementation via generalized polynomial chaos (gPC) expansion. The key ingredients of the proposed approach involve (1) solving the system of stochastic state equations via the gPC methodology to gain efficiency; and (2) sampling the gPC approximation of the stochastic solution with an arbitrarily large number of samples, at virtually no additional computational cost, to drastically reduce the sampling errors. The resulting algorithm thus achieves a high accuracy at reduced computational cost, compared to the classical implementations of EnKF. Numerical examples are provided to verify the convergence property and accuracy improvement of the new algorithm. We also prove that for linear systems with Gaussian noise, the first-order gPC Kalman filter method is equivalent to the exact Kalman filter.

  11. High-accuracy defect sizing for CRDM penetration adapters using the ultrasonic TOFD technique

    International Nuclear Information System (INIS)

    Atkinson, I.

    1995-01-01

    Ultrasonic time-of-flight diffraction (TOFD) is the preferred technique for critical sizing of throughwall orientated defects in a wide range of components, primarily because it is intrinsically more accurate than amplitude-based techniques. For the same reason, TOFD is the preferred technique for sizing the cracks in control rod drive mechanism (CRDM) penetration adapters, which have been the subject of much recent attention. Once the considerable problem of restricted access for the UT probes has been overcome, this inspection lends itself to very high accuracy defect sizing using TOFD. In qualification trials under industrial conditions, depth sizing to an accuracy of ≤ 0.5 mm has been routinely achieved throughout the full wall thickness (16 mm) of the penetration adapters, using only a single probe pair and without recourse to signal processing. (author)

  12. High-Accuracy Tidal Flat Digital Elevation Model Construction Using TanDEM-X Science Phase Data

    Science.gov (United States)

    Lee, Seung-Kuk; Ryu, Joo-Hyung

    2017-01-01

    This study explored the feasibility of using TanDEM-X (TDX) interferometric observations of tidal flats for digital elevation model (DEM) construction. Our goal was to generate high-precision DEMs in tidal flat areas, because accurate intertidal zone data are essential for monitoring coastal environment sand erosion processes. To monitor dynamic coastal changes caused by waves, currents, and tides, very accurate DEMs with high spatial resolution are required. The bi- and monostatic modes of the TDX interferometer employed during the TDX science phase provided a great opportunity for highly accurate intertidal DEM construction using radar interferometry with no time lag (bistatic mode) or an approximately 10-s temporal baseline (monostatic mode) between the master and slave synthetic aperture radar image acquisitions. In this study, DEM construction in tidal flat areas was first optimized based on the TDX system parameters used in various TDX modes. We successfully generated intertidal zone DEMs with 57-m spatial resolutions and interferometric height accuracies better than 0.15 m for three representative tidal flats on the west coast of the Korean Peninsula. Finally, we validated these TDX DEMs against real-time kinematic-GPS measurements acquired in two tidal flat areas; the correlation coefficient was 0.97 with a root mean square error of 0.20 m.

  13. Studies on the diagnostic accuracy of lymphography

    International Nuclear Information System (INIS)

    Luening, M.; Stargardt, A.; Abet, L.

    1979-01-01

    Contradictory reports in the literature on the reliability of lymphography stimulated the authors to test the diagnostic accuracy, employing methods which are approximately analogous to practice, using carcinoma of the cervix as the model on which the study was carried out. Using 21 observers it was found that there was no correlation between their experience and on-target accuracy of the diagnosis. Good observers obtained an accuracy of 85% with good proportions between sensitivity in the recognition of detail, specificity and readiness to arrive at a decision on the basis of discriminatory ability. With the help of the concept of the ROC curves, the position taken up by the observers in respect of diagnostic decisions, and a complex manner of assessing the various characteristic factors determining diagnostic accuracy, are demonstrated. This form of test, which permits manipulation of different variants of diagnosis, is recommended, among other things, for performance control at the end of training and continuing education courses in other fields of x-ray diagnosis as well. (orig.) [de

  14. High accuracy mantle convection simulation through modern numerical methods

    KAUST Repository

    Kronbichler, Martin

    2012-08-21

    Numerical simulation of the processes in the Earth\\'s mantle is a key piece in understanding its dynamics, composition, history and interaction with the lithosphere and the Earth\\'s core. However, doing so presents many practical difficulties related to the numerical methods that can accurately represent these processes at relevant scales. This paper presents an overview of the state of the art in algorithms for high-Rayleigh number flows such as those in the Earth\\'s mantle, and discusses their implementation in the Open Source code Aspect (Advanced Solver for Problems in Earth\\'s ConvecTion). Specifically, we show how an interconnected set of methods for adaptive mesh refinement (AMR), higher order spatial and temporal discretizations, advection stabilization and efficient linear solvers can provide high accuracy at a numerical cost unachievable with traditional methods, and how these methods can be designed in a way so that they scale to large numbers of processors on compute clusters. Aspect relies on the numerical software packages deal.II and Trilinos, enabling us to focus on high level code and keeping our implementation compact. We present results from validation tests using widely used benchmarks for our code, as well as scaling results from parallel runs. © 2012 The Authors Geophysical Journal International © 2012 RAS.

  15. Absolute Astrometry in the next 50 Years - II

    Science.gov (United States)

    Høg, E.

    2018-01-01

    With the Gaia astrometric satellite in orbit since December 2013 it is time to look at the future of fundamental astrometry and a time frame of 50 years is needed in this matter. A space mission with Gaia-like astrometric performance is required, but not necessarily a Gaia-like satellite. A dozen science issues for a Gaia successor mission in twenty years, with launch about 2035, are presented and in this context also other possibilities for absolute astrometry with milliarcsecond (mas) or sub-mas accuracies are discussed in my report at http://arxiv.org/abs/1408.2190. In brief, the two missions (2013 and 2035) would provide an astrometric foundation for all branches of astronomy from the solar system and stellar systems, including exo-planet systems with long periods, to compact galaxies, quasars and Dark Matter substructures by data which cannot be surpassed in the next 50 years.

  16. Measurement system with high accuracy for laser beam quality.

    Science.gov (United States)

    Ke, Yi; Zeng, Ciling; Xie, Peiyuan; Jiang, Qingshan; Liang, Ke; Yang, Zhenyu; Zhao, Ming

    2015-05-20

    Presently, most of the laser beam quality measurement system collimates the optical path manually with low efficiency and low repeatability. To solve these problems, this paper proposed a new collimated method to improve the reliability and accuracy of the measurement results. The system accuracy controlled the position of the mirror to change laser beam propagation direction, which can realize the beam perpendicularly incident to the photosurface of camera. The experiment results show that the proposed system has good repeatability and the measuring deviation of M2 factor is less than 0.6%.

  17. Accuracy of High-Resolution Ultrasonography in the Detection of Extensor Tendon Lacerations.

    Science.gov (United States)

    Dezfuli, Bobby; Taljanovic, Mihra S; Melville, David M; Krupinski, Elizabeth A; Sheppard, Joseph E

    2016-02-01

    Lacerations to the extensor mechanism are usually diagnosed clinically. Ultrasound (US) has been a growing diagnostic tool for tendon injuries since the 1990s. To date, there has been no publication establishing the accuracy and reliability of US in the evaluation of extensor mechanism lacerations in the hand. The purpose of this study is to determine the accuracy of US to detect extensor tendon injuries in the hand. Sixteen fingers and 4 thumbs in 4 fresh-frozen and thawed cadaveric hands were used. Sixty-eight 0.5-cm transverse skin lacerations were created. Twenty-seven extensor tendons were sharply transected. The remaining skin lacerations were used as sham dissection controls. One US technologist and one fellowship-trained musculoskeletal radiologist performed real-time dynamic US studies in and out of water bath. A second fellowship trained musculoskeletal radiologist subsequently reviewed the static US images. Dynamic and static US interpretation accuracy was assessed using dissection as "truth." All 27 extensor tendon lacerations and controls were identified correctly with dynamic imaging as either injury models that had a transected extensor tendon or sham controls with intact extensor tendons (sensitivity = 100%, specificity = 100%, positive predictive value = 1.0; all significantly greater than chance). Static imaging had a sensitivity of 85%, specificity of 89%, and accuracy of 88% (all significantly greater than chance). The results of the dynamic real time versus static US imaging were clearly different but did not reach statistical significance. Diagnostic US is a very accurate noninvasive study that can identify extensor mechanism injuries. Clinically suspected cases of acute extensor tendon injury scanned by high-frequency US can aid and/or confirm the diagnosis, with dynamic imaging providing added value compared to static. Ultrasonography, to aid in the diagnosis of extensor mechanism lacerations, can be successfully used in a reliable and

  18. SU-E-J-03: Characterization of the Precision and Accuracy of a New, Preclinical, MRI-Guided Focused Ultrasound System for Image-Guided Interventions in Small-Bore, High-Field Magnets

    International Nuclear Information System (INIS)

    Ellens, N; Farahani, K

    2015-01-01

    Purpose: MRI-guided focused ultrasound (MRgFUS) has many potential and realized applications including controlled heating and localized drug delivery. The development of many of these applications requires extensive preclinical work, much of it in small animal models. The goal of this study is to characterize the spatial targeting accuracy and reproducibility of a preclinical high field MRgFUS system for thermal ablation and drug delivery applications. Methods: The RK300 (FUS Instruments, Toronto, Canada) is a motorized, 2-axis FUS positioning system suitable for small bore (72 mm), high-field MRI systems. The accuracy of the system was assessed in three ways. First, the precision of the system was assessed by sonicating regular grids of 5 mm squares on polystyrene plates and comparing the resulting focal dimples to the intended pattern, thereby assessing the reproducibility and precision of the motion control alone. Second, the targeting accuracy was assessed by imaging a polystyrene plate with randomly drilled holes and replicating the hole pattern by sonicating the observed hole locations on intact polystyrene plates and comparing the results. Third, the practicallyrealizable accuracy and precision were assessed by comparing the locations of transcranial, FUS-induced blood-brain-barrier disruption (BBBD) (observed through Gadolinium enhancement) to the intended targets in a retrospective analysis of animals sonicated for other experiments. Results: The evenly-spaced grids indicated that the precision was 0.11 +/− 0.05 mm. When image-guidance was included by targeting random locations, the accuracy was 0.5 +/− 0.2 mm. The effective accuracy in the four rodent brains assessed was 0.8 +/− 0.6 mm. In all cases, the error appeared normally distributed (p<0.05) in both orthogonal axes, though the left/right error was systematically greater than the superior/inferior error. Conclusions: The targeting accuracy of this device is sub-millimeter, suitable for many

  19. SU-E-J-03: Characterization of the Precision and Accuracy of a New, Preclinical, MRI-Guided Focused Ultrasound System for Image-Guided Interventions in Small-Bore, High-Field Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Ellens, N [Johns Hopkins University, Baltimore, Maryland (United States); Farahani, K [National Cancer Institute, Bethesda, MD (United States)

    2015-06-15

    Purpose: MRI-guided focused ultrasound (MRgFUS) has many potential and realized applications including controlled heating and localized drug delivery. The development of many of these applications requires extensive preclinical work, much of it in small animal models. The goal of this study is to characterize the spatial targeting accuracy and reproducibility of a preclinical high field MRgFUS system for thermal ablation and drug delivery applications. Methods: The RK300 (FUS Instruments, Toronto, Canada) is a motorized, 2-axis FUS positioning system suitable for small bore (72 mm), high-field MRI systems. The accuracy of the system was assessed in three ways. First, the precision of the system was assessed by sonicating regular grids of 5 mm squares on polystyrene plates and comparing the resulting focal dimples to the intended pattern, thereby assessing the reproducibility and precision of the motion control alone. Second, the targeting accuracy was assessed by imaging a polystyrene plate with randomly drilled holes and replicating the hole pattern by sonicating the observed hole locations on intact polystyrene plates and comparing the results. Third, the practicallyrealizable accuracy and precision were assessed by comparing the locations of transcranial, FUS-induced blood-brain-barrier disruption (BBBD) (observed through Gadolinium enhancement) to the intended targets in a retrospective analysis of animals sonicated for other experiments. Results: The evenly-spaced grids indicated that the precision was 0.11 +/− 0.05 mm. When image-guidance was included by targeting random locations, the accuracy was 0.5 +/− 0.2 mm. The effective accuracy in the four rodent brains assessed was 0.8 +/− 0.6 mm. In all cases, the error appeared normally distributed (p<0.05) in both orthogonal axes, though the left/right error was systematically greater than the superior/inferior error. Conclusions: The targeting accuracy of this device is sub-millimeter, suitable for many

  20. Enhancing the Accuracy of Advanced High Temperature Mechanical Testing through Thermography

    Directory of Open Access Journals (Sweden)

    Jonathan Jones

    2018-03-01

    Full Text Available This paper describes the advantages and enhanced accuracy thermography provides to high temperature mechanical testing. This technique is not only used to monitor, but also to control test specimen temperatures where the infra-red technique enables accurate non-invasive control of rapid thermal cycling for non-metallic materials. Isothermal and dynamic waveforms are employed over a 200–800 °C temperature range to pre-oxidised and coated specimens to assess the capability of the technique. This application shows thermography to be accurate to within ±2 °C of thermocouples, a standardised measurement technique. This work demonstrates the superior visibility of test temperatures previously unobtainable by conventional thermocouples or even more modern pyrometers that thermography can deliver. As a result, the speed and accuracy of thermal profiling, thermal gradient measurements and cold/hot spot identification using the technique has increased significantly to the point where temperature can now be controlled by averaging over a specified area. The increased visibility of specimen temperatures has revealed additional unknown effects such as thermocouple shadowing, preferential crack tip heating within an induction coil, and, fundamental response time of individual measurement techniques which are investigated further.

  1. Technical accuracy of a neuronavigation system measured with a high-precision mechanical micromanipulator.

    Science.gov (United States)

    Kaus, M; Steinmeier, R; Sporer, T; Ganslandt, O; Fahlbusch, R

    1997-12-01

    This study was designed to determine and evaluate the different system-inherent sources of erroneous target localization of a light-emitting diode (LED)-based neuronavigation system (StealthStation, Stealth Technologies, Boulder, CO). The localization accuracy was estimated by applying a high-precision mechanical micromanipulator to move and exactly locate (+/- 0.1 micron) the pointer at multiple positions in the physical three-dimensional space. The localization error was evaluated by calculating the spatial distance between the (known) LED positions and the LED coordinates measured by the neuronavigator. The results are based on a study of approximately 280,000 independent coordinate measurements. The maximum localization error detected was 0.55 +/- 0.29 mm, with the z direction (distance to the camera array) being the most erroneous coordinate. Minimum localization error was found at a distance of 1400 mm from the central camera (optimal measurement position). Additional error due to 1) mechanical vibrations of the camera tripod (+/- 0.15 mm) and the reference frame (+/- 0.08 mm) and 2) extrapolation of the pointer tip position from the LED coordinates of at least +/- 0.12 mm were detected, leading to a total technical error of 0.55 +/- 0.64 mm. Based on this technical accuracy analysis, a set of handling recommendations is proposed, leading to an improved localization accuracy. The localization error could be reduced by 0.3 +/- 0.15 mm by correct camera positioning (1400 mm distance) plus 0.15 mm by vibration-eliminating fixation of the camera. Correct handling of the probe during the operation may improve the accuracy by up to 0.1 mm.

  2. Treatment of Star Catalog Biases in Asteroid Astrometric Observations

    Science.gov (United States)

    2010-01-01

    and 2MASS , have smal- ler estimated position errors; but these catalogs each have limita- tions relative to B1.0. The UCAC2 catalog, introduced in 2004...this limitation.) The all-sky 2MASS catalog, introduced in 2003, contains 470,992,970 objects, with positions accurate to within 0.07 arcsec (Skrutskie...the 2MASS star catalog (Skr- utskie et al., 2006) was chosen as the catalog to which all others were compared. According to its documentation, the

  3. Accuracy and high-speed technique for autoprocessing of Young's fringes

    Science.gov (United States)

    Chen, Wenyi; Tan, Yushan

    1991-12-01

    In this paper, an accurate and high-speed method for auto-processing of Young's fringes is proposed. A group of 1-D sampled intensity values along three or more different directions are taken from Young's fringes, and the fringe spacings of each direction are obtained by 1-D FFT respectively. Two directions that have smaller fringe spacing are selected from all directions. The accurate fringe spacings along these two directions are obtained by using orthogonal coherent phase detection technique (OCPD). The actual spacing and angle of Young's fringes, therefore, can be calculated. In this paper, the principle of OCPD is introduced in detail. The accuracy of the method is evaluated theoretically and experimentally.

  4. Implementation of High Time Delay Accuracy of Ultrasonic Phased Array Based on Interpolation CIC Filter.

    Science.gov (United States)

    Liu, Peilu; Li, Xinghua; Li, Haopeng; Su, Zhikun; Zhang, Hongxu

    2017-10-12

    In order to improve the accuracy of ultrasonic phased array focusing time delay, analyzing the original interpolation Cascade-Integrator-Comb (CIC) filter, an 8× interpolation CIC filter parallel algorithm was proposed, so that interpolation and multichannel decomposition can simultaneously process. Moreover, we summarized the general formula of arbitrary multiple interpolation CIC filter parallel algorithm and established an ultrasonic phased array focusing time delay system based on 8× interpolation CIC filter parallel algorithm. Improving the algorithmic structure, 12.5% of addition and 29.2% of multiplication was reduced, meanwhile the speed of computation is still very fast. Considering the existing problems of the CIC filter, we compensated the CIC filter; the compensated CIC filter's pass band is flatter, the transition band becomes steep, and the stop band attenuation increases. Finally, we verified the feasibility of this algorithm on Field Programming Gate Array (FPGA). In the case of system clock is 125 MHz, after 8× interpolation filtering and decomposition, time delay accuracy of the defect echo becomes 1 ns. Simulation and experimental results both show that the algorithm we proposed has strong feasibility. Because of the fast calculation, small computational amount and high resolution, this algorithm is especially suitable for applications with high time delay accuracy and fast detection.

  5. Implementation of High Time Delay Accuracy of Ultrasonic Phased Array Based on Interpolation CIC Filter

    Directory of Open Access Journals (Sweden)

    Peilu Liu

    2017-10-01

    Full Text Available In order to improve the accuracy of ultrasonic phased array focusing time delay, analyzing the original interpolation Cascade-Integrator-Comb (CIC filter, an 8× interpolation CIC filter parallel algorithm was proposed, so that interpolation and multichannel decomposition can simultaneously process. Moreover, we summarized the general formula of arbitrary multiple interpolation CIC filter parallel algorithm and established an ultrasonic phased array focusing time delay system based on 8× interpolation CIC filter parallel algorithm. Improving the algorithmic structure, 12.5% of addition and 29.2% of multiplication was reduced, meanwhile the speed of computation is still very fast. Considering the existing problems of the CIC filter, we compensated the CIC filter; the compensated CIC filter’s pass band is flatter, the transition band becomes steep, and the stop band attenuation increases. Finally, we verified the feasibility of this algorithm on Field Programming Gate Array (FPGA. In the case of system clock is 125 MHz, after 8× interpolation filtering and decomposition, time delay accuracy of the defect echo becomes 1 ns. Simulation and experimental results both show that the algorithm we proposed has strong feasibility. Because of the fast calculation, small computational amount and high resolution, this algorithm is especially suitable for applications with high time delay accuracy and fast detection.

  6. THE EFFECT OF MODERATE AND HIGH-INTENSITY FATIGUE ON GROUNDSTROKE ACCURACY IN EXPERT AND NON-EXPERT TENNIS PLAYERS

    Directory of Open Access Journals (Sweden)

    Mark Lyons

    2013-06-01

    Full Text Available Exploring the effects of fatigue on skilled performance in tennis presents a significant challenge to the researcher with respect to ecological validity. This study examined the effects of moderate and high-intensity fatigue on groundstroke accuracy in expert and non-expert tennis players. The research also explored whether the effects of fatigue are the same regardless of gender and player's achievement motivation characteristics. 13 expert (7 male, 6 female and 17 non-expert (13 male, 4 female tennis players participated in the study. Groundstroke accuracy was assessed using the modified Loughborough Tennis Skills Test. Fatigue was induced using the Loughborough Intermittent Tennis Test with moderate (70% and high-intensities (90% set as a percentage of peak heart rate (attained during a tennis-specific maximal hitting sprint test. Ratings of perceived exertion were used as an adjunct to the monitoring of heart rate. Achievement goal indicators for each player were assessed using the 2 x 2 Achievement Goals Questionnaire for Sport in an effort to examine if this personality characteristic provides insight into how players perform under moderate and high-intensity fatigue conditions. A series of mixed ANOVA's revealed significant fatigue effects on groundstroke accuracy regardless of expertise. The expert players however, maintained better groundstroke accuracy across all conditions compared to the novice players. Nevertheless, in both groups, performance following high-intensity fatigue deteriorated compared to performance at rest and performance while moderately fatigued. Groundstroke accuracy under moderate levels of fatigue was equivalent to that at rest. Fatigue effects were also similar regardless of gender. No fatigue by expertise, or fatigue by gender interactions were found. Fatigue effects were also equivalent regardless of player's achievement goal indicators. Future research is required to explore the effects of fatigue on

  7. Coronary CT angiography using prospective ECG triggering. High diagnostic accuracy with low radiation dose

    International Nuclear Information System (INIS)

    Arnoldi, E.; Ramos-Duran, L.; Abro, J.A.; Costello, P.; Zwerner, P.L.; Schoepf, U.J.; Nikolaou, K.; Reiser, M.F.

    2010-01-01

    The purpose of this study was to evaluate the diagnostic performance of coronary CT angiography (coronary CTA) using prospective ECG triggering (PT) for the detection of significant coronary artery stenosis compared to invasive coronary angiography (ICA). A total of 20 patients underwent coronary CTA with PT using a 128-slice CT scanner (Definition trademark AS+, Siemens) and ICA. All coronary CTA studies were evaluated for significant coronary artery stenoses (≥50% luminal narrowing) by 2 observers in consensus using the AHA-15-segment model. Findings in CTA were compared to those in ICA. Coronary CTA using PT had 88% sensitivity in comparison to 100% with ICA, 95% to 88% specificity, 80% to 92% positive predictive value and 97% to 100% negative predictive value for diagnosing significant coronary artery stenosis on per segment per patient analysis, respectively. Mean effective radiation dose-equivalent of CTA was 2.6±1 mSv. Coronary CTA using PT enables non-invasive diagnosis of significant coronary artery stenosis with high diagnostic accuracy in comparison to ICA and is associated with comparably low radiation exposure. (orig.) [de

  8. Accuracy and interobserver-intraobserver agreement in the radiologic diagnosis of ameloblastoma and odontogenic keratocyst

    International Nuclear Information System (INIS)

    Choi, Soon Chul; Lee, Jean; Park, In Woo; Lee, Young Ho

    1996-01-01

    Six observers with different amount of experience in the field of Oral and Maxillofacial Radiology interpreted the radiographs of 13 cases of ameloblastoma and 8 cases of odontogenic keratocyst which were confirmed histopathologically and showed pseudo-multilocular appearanced and scalloped border radiographically. The authors examined the accuracy of radiologic diagnoses, interobserver agreement and intraobserver agreement. The obtained results were as follows : 1. The accuracy of radiologic diagnosis ranged from 0.48 to 0.81. The average value was 0.61 2. The accuracy of radiologic diagnosis for ameloblastoma (0.55) was lower than that for odontogenic keratocyst (0.70) (P <0.05). 3. The overall agreement among the 6 observers was 14.3% at the first interpretation and 19.0% at the second interpretation. 4. The intraobserver agreement of each observer expressed in kappa index ranged from -0.14 to 0.64. The overall intraobserver agreement was 0.29. 5. The intraobserver agreement of each observer for ameloblastoma and odontogenic keratocyst ranged from -0.07 to 0.65 and from -0.25 to 1.00, respectively. The overall intraobserver agreement for ameloblastoma and odontogenic keratocyst were 0.27 and 0.26, respectively. 6. The diagnostic accuracy highly correlated to the intraobserver agreement (r=0.6370).

  9. Accuracy and interobserver-intraobserver agreement in the radiologic diagnosis of ameloblastoma and odontogenic keratocyst

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Soon Chul; Lee, Jean; Park, In Woo; Lee, Young Ho [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1996-08-15

    Six observers with different amount of experience in the field of Oral and Maxillofacial Radiology interpreted the radiographs of 13 cases of ameloblastoma and 8 cases of odontogenic keratocyst which were confirmed histopathologically and showed pseudo-multilocular appearanced and scalloped border radiographically. The authors examined the accuracy of radiologic diagnoses, interobserver agreement and intraobserver agreement. The obtained results were as follows : 1. The accuracy of radiologic diagnosis ranged from 0.48 to 0.81. The average value was 0.61 2. The accuracy of radiologic diagnosis for ameloblastoma (0.55) was lower than that for odontogenic keratocyst (0.70) (P <0.05). 3. The overall agreement among the 6 observers was 14.3% at the first interpretation and 19.0% at the second interpretation. 4. The intraobserver agreement of each observer expressed in kappa index ranged from -0.14 to 0.64. The overall intraobserver agreement was 0.29. 5. The intraobserver agreement of each observer for ameloblastoma and odontogenic keratocyst ranged from -0.07 to 0.65 and from -0.25 to 1.00, respectively. The overall intraobserver agreement for ameloblastoma and odontogenic keratocyst were 0.27 and 0.26, respectively. 6. The diagnostic accuracy highly correlated to the intraobserver agreement (r=0.6370).

  10. Cause and Cure - Deterioration in Accuracy of CFD Simulations With Use of High-Aspect-Ratio Triangular Tetrahedral Grids

    Science.gov (United States)

    Chang, Sin-Chung; Chang, Chau-Lyan; Venkatachari, Balaji Shankar

    2017-01-01

    Traditionally high-aspect ratio triangular/tetrahedral meshes are avoided by CFD re-searchers in the vicinity of a solid wall, as it is known to reduce the accuracy of gradient computations in those regions and also cause numerical instability. Although for certain complex geometries, the use of high-aspect ratio triangular/tetrahedral elements in the vicinity of a solid wall can be replaced by quadrilateral/prismatic elements, ability to use triangular/tetrahedral elements in such regions without any degradation in accuracy can be beneficial from a mesh generation point of view. The benefits also carry over to numerical frameworks such as the space-time conservation element and solution element (CESE), where triangular/tetrahedral elements are the mandatory building blocks. With the requirement of the CESE method in mind, a rigorous mathematical framework that clearly identities the reason behind the difficulties in use of such high-aspect ratio triangular/tetrahedral elements is presented here. As will be shown, it turns out that the degree of accuracy deterioration of gradient computation involving a triangular element is hinged on the value of its shape factor Gamma def = sq sin Alpha1 + sq sin Alpha2 + sq sin Alpha3, where Alpha1; Alpha2 and Alpha3 are the internal angles of the element. In fact, it is shown that the degree of accuracy deterioration increases monotonically as the value of Gamma decreases monotonically from its maximal value 9/4 (attained by an equilateral triangle only) to a value much less than 1 (associated with a highly obtuse triangle). By taking advantage of the fact that a high-aspect ratio triangle is not necessarily highly obtuse, and in fact it can have a shape factor whose value is close to the maximal value 9/4, a potential solution to avoid accuracy deterioration of gradient computation associated with a high-aspect ratio triangular grid is given. Also a brief discussion on the extension of the current mathematical framework to the

  11. Very high-accuracy calibration of radiation pattern and gain of a near-field probe

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Nielsen, Jeppe Majlund; Breinbjerg, Olav

    2014-01-01

    In this paper, very high-accuracy calibration of the radiation pattern and gain of a near-field probe is described. An open-ended waveguide near-field probe has been used in a recent measurement of the C-band Synthetic Aperture Radar (SAR) Antenna Subsystem for the Sentinel 1 mission of the Europ...

  12. Modeling Multi-wavelength Stellar Astrometry. III. Determination of the Absolute Masses of Exoplanets and Their Host Stars

    Science.gov (United States)

    Coughlin, J. L.; López-Morales, Mercedes

    2012-05-01

    Astrometric measurements of stellar systems are becoming significantly more precise and common, with many ground- and space-based instruments and missions approaching 1 μas precision. We examine the multi-wavelength astrometric orbits of exoplanetary systems via both analytical formulae and numerical modeling. Exoplanets have a combination of reflected and thermally emitted light that causes the photocenter of the system to shift increasingly farther away from the host star with increasing wavelength. We find that, if observed at long enough wavelengths, the planet can dominate the astrometric motion of the system, and thus it is possible to directly measure the orbits of both the planet and star, and thus directly determine the physical masses of the star and planet, using multi-wavelength astrometry. In general, this technique works best for, though is certainly not limited to, systems that have large, high-mass stars and large, low-mass planets, which is a unique parameter space not covered by other exoplanet characterization techniques. Exoplanets that happen to transit their host star present unique cases where the physical radii of the planet and star can be directly determined via astrometry alone. Planetary albedos and day-night contrast ratios may also be probed via this technique due to the unique signature they impart on the observed astrometric orbits. We develop a tool to examine the prospects for near-term detection of this effect, and give examples of some exoplanets that appear to be good targets for detection in the K to N infrared observing bands, if the required precision can be achieved.

  13. MODELING MULTI-WAVELENGTH STELLAR ASTROMETRY. III. DETERMINATION OF THE ABSOLUTE MASSES OF EXOPLANETS AND THEIR HOST STARS

    International Nuclear Information System (INIS)

    Coughlin, J. L.; López-Morales, Mercedes

    2012-01-01

    Astrometric measurements of stellar systems are becoming significantly more precise and common, with many ground- and space-based instruments and missions approaching 1 μas precision. We examine the multi-wavelength astrometric orbits of exoplanetary systems via both analytical formulae and numerical modeling. Exoplanets have a combination of reflected and thermally emitted light that causes the photocenter of the system to shift increasingly farther away from the host star with increasing wavelength. We find that, if observed at long enough wavelengths, the planet can dominate the astrometric motion of the system, and thus it is possible to directly measure the orbits of both the planet and star, and thus directly determine the physical masses of the star and planet, using multi-wavelength astrometry. In general, this technique works best for, though is certainly not limited to, systems that have large, high-mass stars and large, low-mass planets, which is a unique parameter space not covered by other exoplanet characterization techniques. Exoplanets that happen to transit their host star present unique cases where the physical radii of the planet and star can be directly determined via astrometry alone. Planetary albedos and day-night contrast ratios may also be probed via this technique due to the unique signature they impart on the observed astrometric orbits. We develop a tool to examine the prospects for near-term detection of this effect, and give examples of some exoplanets that appear to be good targets for detection in the K to N infrared observing bands, if the required precision can be achieved.

  14. Photometry and position observations of Saturnian satellites during their mutual eclipses and occultations in 1995 performed at the Observatories in Russia and Kazakhstan

    Science.gov (United States)

    Emelianov, N. V.; Irsmambetova, T. R.; Kiseleva, T. P.; Tejfel, V. G.; Vashkovjak, S. N.; Glushkova, E. A.; Kornilov, V. G.; Charitonova, G. A.

    1999-10-01

    Photometry of mutual eclipses and occultations of planetary satellites is a powerful technique to explore these bodies. Observations of these rare events are a source of much precise information. In 1995 the Celestial Mechanics Department of the Sternberg Astronomical Institute (SAI) has organized the observations of mutual eclipses and occultations of Saturnian satellites on a number of observatories of the Commonwealth of Independent States (CIS) -- the former Soviet Union (FSU). The ephemerides of satellites and their observing conditions have been computed beforehand and mailed these data to many observatories of CIS. The Crimean laboratory (CL) of the Sternberg Astronomical Institute, two observatories of the Fesenkov Astrophysical Institute of the Academy of Sciences of the Republic of Kazakhstan (FAI AS RK) in Almaty, and the Main Astronomical Observatory of Russian Academy of Sciences (MAO RAS) in Pulkovo took part in observations. A photoelectric photometer was used in CL of SAI, a CCD was employed to secure satellite images in FAI AS RK, and both CCD and photographic plates were used in MAO RAS. As a result of this observing campaign, photometric data and light curves were obtained for three mutual eclipses and occultations of Saturnian satellites. A number of position observations made allowed us to measure relative coordinates of satellites. Astrometric information has already been derived from photometric data. The mutual apparent positions of satellites were calculated with an accuracy of 0farcs 002 - 0farcs 003. In this paper observations are described and the parameters characterizing the observed phenomena are given. The results of observations are available in electronic form. This work supported by the Russian Foundation for Basic Research, projects Nos. 95-02-05042, 97-02-16551. Results of observations available in electronic form at CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsweb.u-strasbg.fr/Abstract.html

  15. Meditation experience predicts introspective accuracy.

    Directory of Open Access Journals (Sweden)

    Kieran C R Fox

    Full Text Available The accuracy of subjective reports, especially those involving introspection of one's own internal processes, remains unclear, and research has demonstrated large individual differences in introspective accuracy. It has been hypothesized that introspective accuracy may be heightened in persons who engage in meditation practices, due to the highly introspective nature of such practices. We undertook a preliminary exploration of this hypothesis, examining introspective accuracy in a cross-section of meditation practitioners (1-15,000 hrs experience. Introspective accuracy was assessed by comparing subjective reports of tactile sensitivity for each of 20 body regions during a 'body-scanning' meditation with averaged, objective measures of tactile sensitivity (mean size of body representation area in primary somatosensory cortex; two-point discrimination threshold as reported in prior research. Expert meditators showed significantly better introspective accuracy than novices; overall meditation experience also significantly predicted individual introspective accuracy. These results suggest that long-term meditators provide more accurate introspective reports than novices.

  16. Accuracy Analysis of a Box-wing Theoretical SRP Model

    Science.gov (United States)

    Wang, Xiaoya; Hu, Xiaogong; Zhao, Qunhe; Guo, Rui

    2016-07-01

    For Beidou satellite navigation system (BDS) a high accuracy SRP model is necessary for high precise applications especially with Global BDS establishment in future. The BDS accuracy for broadcast ephemeris need be improved. So, a box-wing theoretical SRP model with fine structure and adding conical shadow factor of earth and moon were established. We verified this SRP model by the GPS Block IIF satellites. The calculation was done with the data of PRN 1, 24, 25, 27 satellites. The results show that the physical SRP model for POD and forecast for GPS IIF satellite has higher accuracy with respect to Bern empirical model. The 3D-RMS of orbit is about 20 centimeters. The POD accuracy for both models is similar but the prediction accuracy with the physical SRP model is more than doubled. We tested 1-day 3-day and 7-day orbit prediction. The longer is the prediction arc length, the more significant is the improvement. The orbit prediction accuracy with the physical SRP model for 1-day, 3-day and 7-day arc length are 0.4m, 2.0m, 10.0m respectively. But they are 0.9m, 5.5m and 30m with Bern empirical model respectively. We apply this means to the BDS and give out a SRP model for Beidou satellites. Then we test and verify the model with Beidou data of one month only for test. Initial results show the model is good but needs more data for verification and improvement. The orbit residual RMS is similar to that with our empirical force model which only estimate the force for along track, across track direction and y-bias. But the orbit overlap and SLR observation evaluation show some improvement. The remaining empirical force is reduced significantly for present Beidou constellation.

  17. From journal to headline: the accuracy of climate science news in Danish high quality newspapers

    DEFF Research Database (Denmark)

    Vestergård, Gunver Lystbæk

    2011-01-01

    analysis to examine the accuracy of Danish high quality newspapers in quoting scientific publications from 1997 to 2009. Out of 88 articles, 46 contained inaccuracies though the majority was found to be insignificant and random. The study concludes that Danish broadsheet newspapers are ‘moderately...

  18. Accuracy of High-Resolution MRI with Lumen Distention in Rectal Cancer Staging and Circumferential Margin Involvement Prediction

    International Nuclear Information System (INIS)

    Iannicelli, Elsa; Di Renzo, Sara; Ferri, Mario; Pilozzi, Emanuela; Di Girolamo, Marco; Sapori, Alessandra; Ziparo, Vincenzo; David, Vincenzo

    2014-01-01

    To evaluate the accuracy of magnetic resonance imaging (MRI) with lumen distention for rectal cancer staging and circumferential resection margin (CRM) involvement prediction. Seventy-three patients with primary rectal cancer underwent high-resolution MRI with a phased-array coil performed using 60-80 mL room air rectal distention, 1-3 weeks before surgery. MRI results were compared to postoperative histopathological findings. The overall MRI T staging accuracy was calculated. CRM involvement prediction and the N staging, the accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were assessed for each T stage. The agreement between MRI and histological results was assessed using weighted-kappa statistics. The overall MRI accuracy for T staging was 93.6% (k = 0.85). The accuracy, sensitivity, specificity, PPV and NPV for each T stage were as follows: 91.8%, 86.2%, 95.5%, 92.6% and 91.3% for the group ≤ T2; 90.4%, 94.6%, 86.1%, 87.5% and 94% for T3; 98,6%, 85.7%, 100%, 100% and 98.5% for T4, respectively. The predictive CRM accuracy was 94.5% (k = 0.86); the sensitivity, specificity, PPV and NPV were 89.5%, 96.3%, 89.5%, and 96.3% respectively. The N staging accuracy was 68.49% (k = 0.4). MRI performed with rectal lumen distention has proved to be an effective technique both for rectal cancer staging and involved CRM predicting

  19. Accuracy of High-Resolution MRI with Lumen Distention in Rectal Cancer Staging and Circumferential Margin Involvement Prediction

    Energy Technology Data Exchange (ETDEWEB)

    Iannicelli, Elsa; Di Renzo, Sara [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Ferri, Mario [Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Pilozzi, Emanuela [Department of Clinical and Molecular Sciences, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Di Girolamo, Marco; Sapori, Alessandra [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Ziparo, Vincenzo [Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); David, Vincenzo [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy)

    2014-07-01

    To evaluate the accuracy of magnetic resonance imaging (MRI) with lumen distention for rectal cancer staging and circumferential resection margin (CRM) involvement prediction. Seventy-three patients with primary rectal cancer underwent high-resolution MRI with a phased-array coil performed using 60-80 mL room air rectal distention, 1-3 weeks before surgery. MRI results were compared to postoperative histopathological findings. The overall MRI T staging accuracy was calculated. CRM involvement prediction and the N staging, the accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were assessed for each T stage. The agreement between MRI and histological results was assessed using weighted-kappa statistics. The overall MRI accuracy for T staging was 93.6% (k = 0.85). The accuracy, sensitivity, specificity, PPV and NPV for each T stage were as follows: 91.8%, 86.2%, 95.5%, 92.6% and 91.3% for the group ≤ T2; 90.4%, 94.6%, 86.1%, 87.5% and 94% for T3; 98,6%, 85.7%, 100%, 100% and 98.5% for T4, respectively. The predictive CRM accuracy was 94.5% (k = 0.86); the sensitivity, specificity, PPV and NPV were 89.5%, 96.3%, 89.5%, and 96.3% respectively. The N staging accuracy was 68.49% (k = 0.4). MRI performed with rectal lumen distention has proved to be an effective technique both for rectal cancer staging and involved CRM predicting.

  20. Gene masking - a technique to improve accuracy for cancer classification with high dimensionality in microarray data.

    Science.gov (United States)

    Saini, Harsh; Lal, Sunil Pranit; Naidu, Vimal Vikash; Pickering, Vincel Wince; Singh, Gurmeet; Tsunoda, Tatsuhiko; Sharma, Alok

    2016-12-05

    High dimensional feature space generally degrades classification in several applications. In this paper, we propose a strategy called gene masking, in which non-contributing dimensions are heuristically removed from the data to improve classification accuracy. Gene masking is implemented via a binary encoded genetic algorithm that can be integrated seamlessly with classifiers during the training phase of classification to perform feature selection. It can also be used to discriminate between features that contribute most to the classification, thereby, allowing researchers to isolate features that may have special significance. This technique was applied on publicly available datasets whereby it substantially reduced the number of features used for classification while maintaining high accuracies. The proposed technique can be extremely useful in feature selection as it heuristically removes non-contributing features to improve the performance of classifiers.

  1. Mapping High-Resolution Soil Moisture over Heterogeneous Cropland Using Multi-Resource Remote Sensing and Ground Observations

    Directory of Open Access Journals (Sweden)

    Lei Fan

    2015-10-01

    Full Text Available High spatial resolution soil moisture (SM data are crucial in agricultural applications, river-basin management, and understanding hydrological processes. Merging multi-resource observations is one of the ways to improve the accuracy of high spatial resolution SM data in the heterogeneous cropland. In this paper, the Bayesian Maximum Entropy (BME methodology is implemented to merge the following four types of observed data to obtain the spatial distribution of SM at 100 m scale: soil moisture observed by wireless sensor network (WSN, Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER-derived soil evaporative efficiency (SEE, irrigation statistics, and Polarimetric L-band Multi-beam Radiometer (PLMR-derived SM products (~700 m. From the poor BME predictions obtained by merging only WSN and SEE data, we observed that the SM heterogeneity caused by irrigation and the attenuating sensitivity of the SEE data to SM caused by the canopies result in BME prediction errors. By adding irrigation statistics to the merged datasets, the overall RMSD of the BME predictions during the low-vegetated periods can be successively reduced from 0.052 m3·m−3 to 0.033 m3·m−3. The coefficient of determination (R2 and slope between the predicted and in situ measured SM data increased from 0.32 to 0.64 and from 0.38 to 0.82, respectively, but large estimation errors occurred during the moderately vegetated periods (RMSD = 0.041 m3·m−3, R = 0.43 and the slope = 0.41. Further adding the downscaled SM information from PLMR SM products to the merged datasets, the predictions were satisfactorily accurate with an RMSD of 0.034 m3·m−3, R2 of 0.4 and a slope of 0.69 during moderately vegetated periods. Overall, the results demonstrated that merging multi-resource observations into SM estimations can yield improved accuracy in heterogeneous cropland.

  2. High-accuracy critical exponents for O(N) hierarchical 3D sigma models

    International Nuclear Information System (INIS)

    Godina, J. J.; Li, L.; Meurice, Y.; Oktay, M. B.

    2006-01-01

    The critical exponent γ and its subleading exponent Δ in the 3D O(N) Dyson's hierarchical model for N up to 20 are calculated with high accuracy. We calculate the critical temperatures for the measure δ(φ-vector.φ-vector-1). We extract the first coefficients of the 1/N expansion from our numerical data. We show that the leading and subleading exponents agree with Polchinski equation and the equivalent Litim equation, in the local potential approximation, with at least 4 significant digits

  3. Geometric Accuracy Investigations of SEVIRI High Resolution Visible (HRV Level 1.5 Imagery

    Directory of Open Access Journals (Sweden)

    Sultan Kocaman Aksakal

    2013-05-01

    Full Text Available GCOS (Global Climate Observing System is a long-term program for monitoring the climate, detecting the changes, and assessing their impacts. Remote sensing techniques are being increasingly used for climate-related measurements. Imagery of the SEVIRI instrument on board of the European geostationary satellites Meteosat-8 and Meteosat-9 are often used for the estimation of essential climate variables. In a joint project between the Swiss GCOS Office and ETH Zurich, geometric accuracy and temporal stability of 1-km resolution HRV channel imagery of SEVIRI have been evaluated over Switzerland. A set of tools and algorithms has been developed for the investigations. Statistical analysis and blunder detection have been integrated in the process for robust evaluation. The relative accuracy is evaluated by tracking large numbers of feature points in consecutive HRV images taken at 15-minute intervals. For the absolute accuracy evaluation, lakes in Switzerland and surroundings are used as reference. 20 lakes digitized from Landsat orthophotos are transformed into HRV images and matched via 2D translation terms at sub-pixel level. The algorithms are tested using HRV images taken on 24 days in 2008 (2 days per month. The results show that 2D shifts that are up to 8 pixels are present both in relative and absolute terms.

  4. High-accuracy numerical integration of charged particle motion – with application to ponderomotive force

    International Nuclear Information System (INIS)

    Furukawa, Masaru; Ohkawa, Yushiro; Matsuyama, Akinobu

    2016-01-01

    A high-accuracy numerical integration algorithm for a charged particle motion is developed. The algorithm is based on the Hamiltonian mechanics and the operator decomposition. The algorithm is made to be time-reversal symmetric, and its order of accuracy can be increased to any order by using a recurrence formula. One of the advantages is that it is an explicit method. An effective way to decompose the time evolution operator is examined; the Poisson tensor is decomposed and non-canonical variables are adopted. The algorithm is extended to a time dependent fields' case by introducing the extended phase space. Numerical tests showing the performance of the algorithm are presented. One is the pure cyclotron motion for a long time period, and the other is a charged particle motion in a rapidly oscillating field. (author)

  5. Quantitative Assessment of Blood Pressure Measurement Accuracy and Variability from Visual Auscultation Method by Observers without Receiving Medical Training

    Science.gov (United States)

    Feng, Yong; Chen, Aiqing

    2017-01-01

    This study aimed to quantify blood pressure (BP) measurement accuracy and variability with different techniques. Thirty video clips of BP recordings from the BHS training database were converted to Korotkoff sound waveforms. Ten observers without receiving medical training were asked to determine BPs using (a) traditional manual auscultatory method and (b) visual auscultation method by visualizing the Korotkoff sound waveform, which was repeated three times on different days. The measurement error was calculated against the reference answers, and the measurement variability was calculated from the SD of the three repeats. Statistical analysis showed that, in comparison with the auscultatory method, visual method significantly reduced overall variability from 2.2 to 1.1 mmHg for SBP and from 1.9 to 0.9 mmHg for DBP (both p auscultation methods). In conclusion, the visual auscultation method had the ability to achieve an acceptable degree of BP measurement accuracy, with smaller variability in comparison with the traditional auscultatory method. PMID:29423405

  6. Geoid undulation accuracy

    Science.gov (United States)

    Rapp, Richard H.

    1993-01-01

    The determination of the geoid and equipotential surface of the Earth's gravity field, has long been of interest to geodesists and oceanographers. The geoid provides a surface to which the actual ocean surface can be compared with the differences implying information on the circulation patterns of the oceans. For use in oceanographic applications the geoid is ideally needed to a high accuracy and to a high resolution. There are applications that require geoid undulation information to an accuracy of +/- 10 cm with a resolution of 50 km. We are far from this goal today but substantial improvement in geoid determination has been made. In 1979 the cumulative geoid undulation error to spherical harmonic degree 20 was +/- 1.4 m for the GEM10 potential coefficient model. Today the corresponding value has been reduced to +/- 25 cm for GEM-T3 or +/- 11 cm for the OSU91A model. Similar improvements are noted by harmonic degree (wave-length) and in resolution. Potential coefficient models now exist to degree 360 based on a combination of data types. This paper discusses the accuracy changes that have taken place in the past 12 years in the determination of geoid undulations.

  7. High-accuracy measurements of snow Bidirectional Reflectance Distribution Function at visible and NIR wavelengths – comparison with modelling results

    Directory of Open Access Journals (Sweden)

    M. Dumont

    2010-03-01

    Full Text Available High-accuracy measurements of snow Bidirectional Reflectance Distribution Function (BRDF were performed for four natural snow samples with a spectrogonio-radiometer in the 500–2600 nm wavelength range. These measurements are one of the first sets of direct snow BRDF values over a wide range of lighting and viewing geometry. They were compared to BRDF calculated with two optical models. Variations of the snow anisotropy factor with lighting geometry, wavelength and snow physical properties were investigated. Results show that at wavelengths with small penetration depth, scattering mainly occurs in the very top layers and the anisotropy factor is controlled by the phase function. In this condition, forward scattering peak or double scattering peak is observed. In contrast at shorter wavelengths, the penetration of the radiation is much deeper and the number of scattering events increases. The anisotropy factor is thus nearly constant and decreases at grazing observation angles. The whole dataset is available on demand from the corresponding author.

  8. HIGH-PRECISION RADIO AND INFRARED ASTROMETRY OF LSPM J1314+1320AB. I. PARALLAX, PROPER MOTIONS, AND LIMITS ON PLANETS

    Energy Technology Data Exchange (ETDEWEB)

    Forbrich, Jan [University of Vienna, Department of Astrophysics, Türkenschanzstr. 17, A-1180 Vienna (Austria); Dupuy, Trent J.; Rizzuto, Aaron; Mann, Andrew W.; Kraus, Adam L. [The University of Texas at Austin, Department of Astronomy, 2515 Speedway C1400, Austin, TX 78712 (United States); Reid, Mark J.; Berger, Edo [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Liu, Michael C.; Aller, Kimberly [Institute for Astronomy, University of Hawai’i, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States)

    2016-08-10

    We present multi-epoch astrometric radio observations with the Very Long Baseline Array (VLBA) of the young ultracool-dwarf binary LSPM J1314+1320AB. The radio emission comes from the secondary star. Combining the VLBA data with Keck near-infrared adaptive-optics observations of both components, a full astrometric fit of parallax (π {sub abs} = 57.975 ± 0.045 mas, corresponding to a distance of d = 17.249 ± 0.013 pc), proper motion (μ {sub α} {sub cos} {sub δ} = −247.99 ± 0.10 mas yr{sup −1}, μ {sub δ} = −183.58 ± 0.22 mas yr{sup −1}), and orbital motion is obtained. Despite the fact that the two components have nearly identical masses to within ±2%, the secondary’s radio emission exceeds that of the primary by a factor of ≳30, suggesting a difference in stellar rotation history, which could result in different magnetic field configurations. Alternatively, the emission could be anisotropic and beamed toward us for the secondary but not for the primary. Using only reflex motion, we exclude planets of mass 0.7–10 M {sub jup} with orbital periods of 600–10 days, respectively. Additionally, we use the full orbital solution of the binary to derive an upper limit for the semimajor axis of 0.23 au for stable planetary orbits within this system. These limits cover a parameter space that is inaccessible with, and complementary to, near-infrared radial velocity surveys of ultracool dwarfs. Our absolute astrometry will constitute an important test for the astrometric calibration of Gaia .

  9. An output amplitude configurable wideband automatic gain control with high gain step accuracy

    International Nuclear Information System (INIS)

    He Xiaofeng; Ye Tianchun; Mo Taishan; Ma Chengyan

    2012-01-01

    An output amplitude configurable wideband automatic gain control (AGC) with high gain step accuracy for the GNSS receiver is presented. The amplitude of an AGC is configurable in order to cooperate with baseband chips to achieve interference suppression and be compatible with different full range ADCs. And what's more, the gain-boosting technology is introduced and the circuit is improved to increase the step accuracy. A zero, which is composed by the source feedback resistance and the source capacity, is introduced to compensate for the pole. The AGC is fabricated in a 0.18 μm CMOS process. The AGC shows a 62 dB gain control range by 1 dB each step with a gain error of less than 0.2 dB. The AGC provides 3 dB bandwidth larger than 80 MHz and the overall power consumption is less than 1.8 mA, and the die area is 800 × 300 μm 2 . (semiconductor integrated circuits)

  10. High accuracy magnetic field mapping of the LEP spectrometer magnet

    CERN Document Server

    Roncarolo, F

    2000-01-01

    The Large Electron Positron accelerator (LEP) is a storage ring which has been operated since 1989 at the European Laboratory for Particle Physics (CERN), located in the Geneva area. It is intended to experimentally verify the Standard Model theory and in particular to detect with high accuracy the mass of the electro-weak force bosons. Electrons and positrons are accelerated inside the LEP ring in opposite directions and forced to collide at four locations, once they reach an energy high enough for the experimental purposes. During head-to-head collisions the leptons loose all their energy and a huge amount of energy is concentrated in a small region. In this condition the energy is quickly converted in other particles which tend to go away from the interaction point. The higher the energy of the leptons before the collisions, the higher the mass of the particles that can escape. At LEP four large experimental detectors are accommodated. All detectors are multi purpose detectors covering a solid angle of alm...

  11. ArcticDEM Validation and Accuracy Assessment

    Science.gov (United States)

    Candela, S. G.; Howat, I.; Noh, M. J.; Porter, C. C.; Morin, P. J.

    2017-12-01

    ArcticDEM comprises a growing inventory Digital Elevation Models (DEMs) covering all land above 60°N. As of August, 2017, ArcticDEM had openly released 2-m resolution, individual DEM covering over 51 million km2, which includes areas of repeat coverage for change detection, as well as over 15 million km2 of 5-m resolution seamless mosaics. By the end of the project, over 80 million km2 of 2-m DEMs will be produced, averaging four repeats of the 20 million km2 Arctic landmass. ArcticDEM is produced from sub-meter resolution, stereoscopic imagery using open source software (SETSM) on the NCSA Blue Waters supercomputer. These DEMs have known biases of several meters due to errors in the sensor models generated from satellite positioning. These systematic errors are removed through three-dimensional registration to high-precision Lidar or other control datasets. ArcticDEM is registered to seasonally-subsetted ICESat elevations due its global coverage and high report accuracy ( 10 cm). The vertical accuracy of ArcticDEM is then obtained from the statistics of the fit to the ICESat point cloud, which averages -0.01 m ± 0.07 m. ICESat, however, has a relatively coarse measurement footprint ( 70 m) which may impact the precision of the registration. Further, the ICESat data predates the ArcticDEM imagery by a decade, so that temporal changes in the surface may also impact the registration. Finally, biases may exist between different the different sensors in the ArcticDEM constellation. Here we assess the accuracy of ArcticDEM and the ICESat registration through comparison to multiple high-resolution airborne lidar datasets that were acquired within one year of the imagery used in ArcticDEM. We find the ICESat dataset is performing as anticipated, introducing no systematic bias during the coregistration process, and reducing vertical errors to within the uncertainty of the airborne Lidars. Preliminary sensor comparisons show no significant difference post coregistration

  12. Determination of UAV position using high accuracy navigation platform

    Directory of Open Access Journals (Sweden)

    Ireneusz Kubicki

    2016-07-01

    Full Text Available The choice of navigation system for mini UAV is very important because of its application and exploitation, particularly when the installed on it a synthetic aperture radar requires highly precise information about an object’s position. The presented exemplary solution of such a system draws attention to the possible problems associated with the use of appropriate technology, sensors, and devices or with a complete navigation system. The position and spatial orientation errors of the measurement platform influence on the obtained SAR imaging. Both, turbulences and maneuvers performed during flight cause the changes in the position of the airborne object resulting in deterioration or lack of images from SAR. Consequently, it is necessary to perform operations for reducing or eliminating the impact of the sensors’ errors on the UAV position accuracy. You need to look for compromise solutions between newer better technologies and in the field of software. Keywords: navigation systems, unmanned aerial vehicles, sensors integration

  13. A high accuracy algorithm of displacement measurement for a micro-positioning stage

    Directory of Open Access Journals (Sweden)

    Xiang Zhang

    2017-05-01

    Full Text Available A high accuracy displacement measurement algorithm for a two degrees of freedom compliant precision micro-positioning stage is proposed based on the computer micro-vision technique. The algorithm consists of an integer-pixel and a subpixel matching procedure. Series of simulations are conducted to verify the proposed method. The results show that the proposed algorithm possesses the advantages of high precision and stability, the resolution can attain to 0.01 pixel theoretically. In addition, the consuming time is reduced about 6.7 times compared with the classical normalized cross correlation algorithm. To validate the practical performance of the proposed algorithm, a laser interferometer measurement system (LIMS is built up. The experimental results demonstrate that the algorithm has better adaptability than that of the LIMS.

  14. Radiometric inter-sensor cross-calibration uncertainty using a traceable high accuracy reference hyperspectral imager

    Science.gov (United States)

    Gorroño, Javier; Banks, Andrew C.; Fox, Nigel P.; Underwood, Craig

    2017-08-01

    Optical earth observation (EO) satellite sensors generally suffer from drifts and biases relative to their pre-launch calibration, caused by launch and/or time in the space environment. This places a severe limitation on the fundamental reliability and accuracy that can be assigned to satellite derived information, and is particularly critical for long time base studies for climate change and enabling interoperability and Analysis Ready Data. The proposed TRUTHS (Traceable Radiometry Underpinning Terrestrial and Helio-Studies) mission is explicitly designed to address this issue through re-calibrating itself directly to a primary standard of the international system of units (SI) in-orbit and then through the extension of this SI-traceability to other sensors through in-flight cross-calibration using a selection of Committee on Earth Observation Satellites (CEOS) recommended test sites. Where the characteristics of the sensor under test allows, this will result in a significant improvement in accuracy. This paper describes a set of tools, algorithms and methodologies that have been developed and used in order to estimate the radiometric uncertainty achievable for an indicative target sensor through in-flight cross-calibration using a well-calibrated hyperspectral SI-traceable reference sensor with observational characteristics such as TRUTHS. In this study, Multi-Spectral Imager (MSI) of Sentinel-2 and Landsat-8 Operational Land Imager (OLI) is evaluated as an example, however the analysis is readily translatable to larger-footprint sensors such as Sentinel-3 Ocean and Land Colour Instrument (OLCI) and Visible Infrared Imaging Radiometer Suite (VIIRS). This study considers the criticality of the instrumental and observational characteristics on pixel level reflectance factors, within a defined spatial region of interest (ROI) within the target site. It quantifies the main uncertainty contributors in the spectral, spatial, and temporal domains. The resultant tool

  15. MICADO: first light imager for the E-ELT

    NARCIS (Netherlands)

    Davies, R.; Schubert, J.; Hartl, M.; Alves, J.; Clénet, Y.; Lang-Bardl, F.; Nicklas, H.; Pott, J. -U; Ragazzoni, R.; Tolstoy, E.; Agocs, T.; Anwand-Heerwart, H.; Barboza, S.; Baudoz, P.; Bender, R.; Bizenberger, P.; Boccaletti, A.; Boland, W.; Bonifacio, P.; Briegel, F.; Buey, T.; Chapron, F.; Cohen, M.; Czoske, O.; Dreizler, S.; Falomo, R.; Feautrier, P.; Förster Schreiber, N.; Gendron, E.; Genzel, R.; Glück, M.; Gratadour, D.; Greimel, R.; Grupp, F.; Häuser, M.; Haug, M.; Hennawi, J.; Hess, H. J.; Hörmann, V.; Hofferbert, R.; Hopp, U.; Hubert, Z.; Ives, D.; Kausch, W.; Kerber, F.; Kravcar, H.; Kuijken, K.; Leitzinger, M.; Leschinski, K.; Massari, D.; Mei, S.; Merlin, F.; Mohr, L.; Monna, A.; Müller, F.; Navarro, R.; Plattner, M.; Przybilla, N.; Ramlau, R.; Ramsay, S.; Ratzka, T.; Rhode, P.; Richter, J.; Rix, H. -W; Rodeghiero, G.; Rohloff, R. -R; Rousset, G.; Ruddenklau, R.; Schaffenroth, V.; Schlichter, J.; Sevin, A.; Stuik, R.; Sturm, E.; Thomas, J.; Tromp, N.; Turatto, M.; Verdoes-Kleijn, G.; Vidal, F.; Wagner, R.; Wegner, M.; Zeilinger, W.; Ziegler, B.; Zins, G.

    2016-01-01

    MICADO will equip the E-ELT with a first light capability for diffraction limited imaging at near-infrared wavelengths. The instrument's observing modes focus on various flavours of imaging, including astrometric, high contrast, and time resolved. There is also a single object spectroscopic mode

  16. SYSTEMATIC BIASES IN THE OBSERVED DISTRIBUTION OF KUIPER BELT OBJECT ORBITS

    International Nuclear Information System (INIS)

    Jones, R. L.; Parker, J. Wm.; Bieryla, A.; Marsden, B. G.; Gladman, B.; Kavelaars, JJ.; Petit, J.-M.

    2010-01-01

    The orbital distribution of Kuiper Belt objects (KBOs) provides important tests of solar system evolution models. However, our understanding of this orbital distribution can be affected by many observational biases. An important but difficult to quantify bias results from tracking selection effects; KBOs are recovered or lost depending on assumptions made about their orbital elements when fitting the initial (short) observational arc. Quantitatively studying the effects and significance of this bias is generally difficult, because only the objects where the assumptions were correct are recovered and thus available to study 'the problem', and because different observers use different assumptions and methods. We have used a sample of 38 KBOs that were discovered and tracked, bias-free, as part of the Canada-France Ecliptic Plane Survey to evaluate the potential for losing objects based on the two most common orbit and ephemeris prediction sources: the Minor Planet Center (MPC) and the Bernstein and Khushalani (BK) orbit fitting code. In both cases, we use early discovery and recovery astrometric measurements of the objects to generate ephemeris predictions that we then compare to later positional measurements; objects that have large differences between the predicted and actual positions would be unlikely to be recovered and are thus considered 'lost'. We find systematic differences in the orbit distributions which would result from using the two orbit-fitting procedures. In our sample, the MPC-derived orbit solutions lost slightly fewer objects (five out of 38) due to large ephemeris errors at one year recovery, but the objects which were lost belonged to more 'unusual' orbits such as scattering disk objects or objects with semimajor axes interior to the 3:2 resonance. Using the BK code, more objects (seven out of 38) would have been lost due to ephemeris errors, but the lost objects came from a range of orbital regions, primarily the classical belt region. We also

  17. High-accuracy self-calibration method for dual-axis rotation-modulating RLG-INS

    Science.gov (United States)

    Wei, Guo; Gao, Chunfeng; Wang, Qi; Wang, Qun; Long, Xingwu

    2017-05-01

    Inertial navigation system has been the core component of both military and civil navigation systems. Dual-axis rotation modulation can completely eliminate the inertial elements constant errors of the three axes to improve the system accuracy. But the error caused by the misalignment angles and the scale factor error cannot be eliminated through dual-axis rotation modulation. And discrete calibration method cannot fulfill requirements of high-accurate calibration of the mechanically dithered ring laser gyroscope navigation system with shock absorbers. This paper has analyzed the effect of calibration error during one modulated period and presented a new systematic self-calibration method for dual-axis rotation-modulating RLG-INS. Procedure for self-calibration of dual-axis rotation-modulating RLG-INS has been designed. The results of self-calibration simulation experiment proved that: this scheme can estimate all the errors in the calibration error model, the calibration precision of the inertial sensors scale factor error is less than 1ppm and the misalignment is less than 5″. These results have validated the systematic self-calibration method and proved its importance for accuracy improvement of dual -axis rotation inertial navigation system with mechanically dithered ring laser gyroscope.

  18. [Method for evaluating the positional accuracy of a six-degrees-of-freedom radiotherapy couch using high definition digital cameras].

    Science.gov (United States)

    Takemura, Akihiro; Ueda, Shinichi; Noto, Kimiya; Kurata, Yuichi; Shoji, Saori

    2011-01-01

    In this study, we proposed and evaluated a positional accuracy assessment method with two high-resolution digital cameras for add-on six-degrees-of-freedom radiotherapy (6D) couches. Two high resolution digital cameras (D5000, Nikon Co.) were used in this accuracy assessment method. These cameras were placed on two orthogonal axes of a linear accelerator (LINAC) coordinate system and focused on the isocenter of the LINAC. Pictures of a needle that was fixed on the 6D couch were taken by the cameras during couch motions of translation and rotation of each axis. The coordinates of the needle in the pictures were obtained using manual measurement, and the coordinate error of the needle was calculated. The accuracy of a HexaPOD evo (Elekta AB, Sweden) was evaluated using this method. All of the mean values of the X, Y, and Z coordinate errors in the translation tests were within ±0.1 mm. However, the standard deviation of the Z coordinate errors in the Z translation test was 0.24 mm, which is higher than the others. In the X rotation test, we found that the X coordinate of the rotational origin of the 6D couch was shifted. We proposed an accuracy assessment method for a 6D couch. The method was able to evaluate the accuracy of the motion of only the 6D couch and revealed the deviation of the origin of the couch rotation. This accuracy assessment method is effective for evaluating add-on 6D couch positioning.

  19. Synchrotron accelerator technology for proton beam therapy with high accuracy

    International Nuclear Information System (INIS)

    Hiramoto, Kazuo

    2009-01-01

    Proton beam therapy was applied at the beginning to head and neck cancers, but it is now extended to prostate, lung and liver cancers. Thus the need for a pencil beam scanning method is increasing. With this method radiation dose concentration property of the proton beam will be further intensified. Hitachi group has supplied a pencil beam scanning therapy system as the first one for M. D. Anderson Hospital in United States, and it has been operational since May 2008. Hitachi group has been developing proton therapy system to correspond high-accuracy proton therapy to concentrate the dose in the diseased part which is located with various depths, and which sometimes has complicated shape. The author described here on the synchrotron accelerator technology that is an important element for constituting the proton therapy system. (K.Y.)

  20. A Weekend Workshop on Double Stars for Students

    Science.gov (United States)

    Brewer, Mark; Estrada, Chris; Estrada, Reed; Gillette, Sean

    2016-01-01

    A weekend double star workshop was held by Vanguard Preparatory for selected eighth grade students with the purpose of introducing them to astrometric observational science. The students were selected based on an essay provided by their language arts class. Collaboration with local visiting astronomers was established to provide telescopes equipped with an astrometric eyepiece, observational supervision, and expertise. During the workshop students learned how to determine the scale constant of an astrometric eyepiece, and the procedure for measuring separations and position angles of double stars. The students compared their data to past measurements reported in the Washington Double Star Catalog. Three goals were set for the student's outcome: 1) observe, record, and report observations of double stars, 2) write a scientific paper for publication in the Journal of Double Star Observations, and 3) present a PowerPoint presentation to their peers. This paper chronicles the planning, preparation, funding, and execution required to complete a double star workshop at a public middle school.

  1. Consumer health information on the Internet about carpal tunnel syndrome: indicators of accuracy.

    Science.gov (United States)

    Frické, Martin; Fallis, Don; Jones, Marci; Luszko, Gianna M

    2005-02-01

    To identify indicators of accuracy for consumer health information on the Internet. Several popular search engines were used to find websites on carpal tunnel syndrome. The accuracy and completeness of these sites were determined by orthopedic surgeons. It also was noted whether proposed indicators of accuracy were present. The correlation between proposed indicators of accuracy and the actual accuracy of the sites was calculated. A total of 116 websites and 29 candidate indicators were examined. A high Google toolbar rating of the main page of a site, many inlinks to the main page of a site, and an unbiased presentation of information on carpal tunnel syndrome were considered genuine indicators of accuracy. Many proposed indicators taken from published guidelines did not indicate accuracy (e.g., the author or sponsor having medical credentials). There are genuine indicators of the accuracy of health information on the Internet. Determining these indicators, and informing providers and consumers of health information about them, would be useful for public health care. Published guidelines have proposed many indicators that are obvious to unaided observation by the consumer. However, indicators that make use of the invisible link structure of the Internet are more reliable guides to accurate information on carpal tunnel syndrome.

  2. PACMAN Project: A New Solution for the High-accuracy Alignment of Accelerator Components

    CERN Document Server

    Mainaud Durand, Helene; Buzio, Marco; Caiazza, Domenico; Catalán Lasheras, Nuria; Cherif, Ahmed; Doytchinov, Iordan; Fuchs, Jean-Frederic; Gaddi, Andrea; Galindo Munoz, Natalia; Gayde, Jean-Christophe; Kamugasa, Solomon; Modena, Michele; Novotny, Peter; Russenschuck, Stephan; Sanz, Claude; Severino, Giordana; Tshilumba, David; Vlachakis, Vasileios; Wendt, Manfred; Zorzetti, Silvia

    2016-01-01

    The beam alignment requirements for the next generation of lepton colliders have become increasingly challenging. As an example, the alignment requirements for the three major collider components of the CLIC linear collider are as follows. Before the first beam circulates, the Beam Position Monitors (BPM), Accelerating Structures (AS)and quadrupoles will have to be aligned up to 10 μm w.r.t. a straight line over 200 m long segments, along the 20 km of linacs. PACMAN is a study on Particle Accelerator Components' Metrology and Alignment to the Nanometre scale. It is an Innovative Doctoral Program, funded by the EU and hosted by CERN, providing high quality training to 10 Early Stage Researchers working towards a PhD thesis. The technical aim of the project is to improve the alignment accuracy of the CLIC components by developing new methods and tools addressing several steps of alignment simultaneously, to gain time and accuracy. The tools and methods developed will be validated on a test bench. This paper pr...

  3. Horizontal Positional Accuracy of Google Earth’s High-Resolution Imagery Archive

    Directory of Open Access Journals (Sweden)

    David Potere

    2008-12-01

    Full Text Available Google Earth now hosts high-resolution imagery that spans twenty percent of the Earth’s landmass and more than a third of the human population. This contemporary highresolution archive represents a significant, rapidly expanding, cost-free and largely unexploited resource for scientific inquiry. To increase the scientific utility of this archive, we address horizontal positional accuracy (georegistration by comparing Google Earth with Landsat GeoCover scenes over a global sample of 436 control points located in 109 cities worldwide. Landsat GeoCover is an orthorectified product with known absolute positional accuracy of less than 50 meters root-mean-squared error (RMSE. Relative to Landsat GeoCover, the 436 Google Earth control points have a positional accuracy of 39.7 meters RMSE (error magnitudes range from 0.4 to 171.6 meters. The control points derived from satellite imagery have an accuracy of 22.8 meters RMSE, which is significantly more accurate than the 48 control-points based on aerial photography (41.3 meters RMSE; t-test p-value < 0.01. The accuracy of control points in more-developed countries is 24.1 meters RMSE, which is significantly more accurate than the control points in developing countries (44.4 meters RMSE; t-test p-value < 0.01. These findings indicate that Google Earth highresolution imagery has a horizontal positional accuracy that is sufficient for assessing moderate-resolution remote sensing products across most of the world’s peri-urban areas.

  4. A new device for liver cancer biomarker detection with high accuracy

    Directory of Open Access Journals (Sweden)

    Shuaipeng Wang

    2015-06-01

    Full Text Available A novel cantilever array-based bio-sensor was batch-fabricated with IC compatible MEMS technology for precise liver cancer bio-marker detection. A micro-cavity was designed in the free end of the cantilever for local antibody-immobilization, thus adsorption of the cancer biomarker is localized in the micro-cavity, and the adsorption-induced k variation can be dramatically reduced with comparison to that caused by adsorption of the whole lever. The cantilever is pizeoelectrically driven into vibration which is pizeoresistively sensed by Wheatstone bridge. These structural features offer several advantages: high sensitivity, high throughput, high mass detection accuracy, and small volume. In addition, an analytical model has been established to eliminate the effect of adsorption-induced lever stiffness change and has been applied to precise mass detection of cancer biomarker AFP, the detected AFP antigen mass (7.6 pg/ml is quite close to the calculated one (5.5 pg/ml, two orders of magnitude better than the value by the fully antibody-immobilized cantilever sensor. These approaches will promote real application of the cantilever sensors in early diagnosis of cancer.

  5. Identifying the source of farmed escaped Atlantic salmon (Salmo salar): Bayesian clustering analysis increases accuracy of assignment

    DEFF Research Database (Denmark)

    Glover, Kevin A.; Hansen, Michael Møller; Skaala, Oystein

    2009-01-01

    44 cages located on 26 farms in the Hardangerfjord, western Norway. This fjord represents one of the major salmon farming areas in Norway, with a production of 57,000 t in 2007. Based upon genetic data from 17 microsatellite markers, significant but highly variable differentiation was observed among....... Accuracy of assignment varied greatly among the individual samples. For the Bayesian clustered data set consisting of five genetic groups, overall accuracy of self-assignment was 99%, demonstrating the effectiveness of this strategy to significantly increase accuracy of assignment, albeit at the expense...

  6. The NANOGrav 11-year Data Set: High-precision Timing of 45 Millisecond Pulsars

    Science.gov (United States)

    Arzoumanian, Zaven; Brazier, Adam; Burke-Spolaor, Sarah; Chamberlin, Sydney; Chatterjee, Shami; Christy, Brian; Cordes, James M.; Cornish, Neil J.; Crawford, Fronefield; Thankful Cromartie, H.; Crowter, Kathryn; DeCesar, Megan E.; Demorest, Paul B.; Dolch, Timothy; Ellis, Justin A.; Ferdman, Robert D.; Ferrara, Elizabeth C.; Fonseca, Emmanuel; Garver-Daniels, Nathan; Gentile, Peter A.; Halmrast, Daniel; Huerta, E. A.; Jenet, Fredrick A.; Jessup, Cody; Jones, Glenn; Jones, Megan L.; Kaplan, David L.; Lam, Michael T.; Lazio, T. Joseph W.; Levin, Lina; Lommen, Andrea; Lorimer, Duncan R.; Luo, Jing; Lynch, Ryan S.; Madison, Dustin; Matthews, Allison M.; McLaughlin, Maura A.; McWilliams, Sean T.; Mingarelli, Chiara; Ng, Cherry; Nice, David J.; Pennucci, Timothy T.; Ransom, Scott M.; Ray, Paul S.; Siemens, Xavier; Simon, Joseph; Spiewak, Renée; Stairs, Ingrid H.; Stinebring, Daniel R.; Stovall, Kevin; Swiggum, Joseph K.; Taylor, Stephen R.; Vallisneri, Michele; van Haasteren, Rutger; Vigeland, Sarah J.; Zhu, Weiwei; The NANOGrav Collaboration

    2018-04-01

    We present high-precision timing data over time spans of up to 11 years for 45 millisecond pulsars observed as part of the North American Nanohertz Observatory for Gravitational Waves (NANOGrav) project, aimed at detecting and characterizing low-frequency gravitational waves. The pulsars were observed with the Arecibo Observatory and/or the Green Bank Telescope at frequencies ranging from 327 MHz to 2.3 GHz. Most pulsars were observed with approximately monthly cadence, and six high-timing-precision pulsars were observed weekly. All were observed at widely separated frequencies at each observing epoch in order to fit for time-variable dispersion delays. We describe our methods for data processing, time-of-arrival (TOA) calculation, and the implementation of a new, automated method for removing outlier TOAs. We fit a timing model for each pulsar that includes spin, astrometric, and (for binary pulsars) orbital parameters; time-variable dispersion delays; and parameters that quantify pulse-profile evolution with frequency. The timing solutions provide three new parallax measurements, two new Shapiro delay measurements, and two new measurements of significant orbital-period variations. We fit models that characterize sources of noise for each pulsar. We find that 11 pulsars show significant red noise, with generally smaller spectral indices than typically measured for non-recycled pulsars, possibly suggesting a different origin. A companion paper uses these data to constrain the strength of the gravitational-wave background.

  7. Accuracy of Self-Esteem Judgments at Zero Acquaintance.

    Science.gov (United States)

    Hirschmüller, Sarah; Schmukle, Stefan C; Krause, Sascha; Back, Mitja D; Egloff, Boris

    2018-04-01

    Perceptions of strangers' self-esteem can have wide-ranging interpersonal consequences. Aiming to reconcile inconsistent results from previous research that had predominantly suggested that self-esteem is a trait that can hardly be accurately judged at zero acquaintance, we examined unaquainted others' accuracy in inferring individuals' actual self-esteem. Ninety-nine target participants (77 female; M age  = 23.5 years) were videotaped in a self-introductory situation, and self-esteem self-reports and reports by well-known informants were obtained as separate accuracy criteria. Forty unacquainted observers judged targets' self-esteem on the basis of these short video sequences (M = 23s, SD = 7.7). Results showed that both self-reported (r = .31, p = .002) and informant-reported self-esteem (r = .21, p = .040) of targets could be inferred by strangers. The degree of accuracy in self-esteem judgments could be explained with lens model analyses: Self- and informant-reported self-esteem predicted nonverbal and vocal friendliness, both of which predicted self-esteem judgments by observers. In addition, observers' accuracy in inferring informant-reported self-esteem was mediated by the utilization of targets' physical attractiveness. Besides using valid behavioral information to infer strangers' self-esteem, observers inappropriately relied on invalid behavioral information reflecting nonverbal, vocal, and verbal self-assuredness. Our findings show that strangers can quite accurately detect individuals' self-reported and informant-reported self-esteem when targets are observed in a public self-presentational situation. © 2017 Wiley Periodicals, Inc.

  8. Broadband EIT borehole measurements with high phase accuracy using numerical corrections of electromagnetic coupling effects

    International Nuclear Information System (INIS)

    Zhao, Y; Zimmermann, E; Wolters, B; Van Waasen, S; Huisman, J A; Treichel, A; Kemna, A

    2013-01-01

    Electrical impedance tomography (EIT) is gaining importance in the field of geophysics and there is increasing interest for accurate borehole EIT measurements in a broad frequency range (mHz to kHz) in order to study subsurface properties. To characterize weakly polarizable soils and sediments with EIT, high phase accuracy is required. Typically, long electrode cables are used for borehole measurements. However, this may lead to undesired electromagnetic coupling effects associated with the inductive coupling between the double wire pairs for current injection and potential measurement and the capacitive coupling between the electrically conductive shield of the cable and the electrically conductive environment surrounding the electrode cables. Depending on the electrical properties of the subsurface and the measured transfer impedances, both coupling effects can cause large phase errors that have typically limited the frequency bandwidth of field EIT measurements to the mHz to Hz range. The aim of this paper is to develop numerical corrections for these phase errors. To this end, the inductive coupling effect was modeled using electronic circuit models, and the capacitive coupling effect was modeled by integrating discrete capacitances in the electrical forward model describing the EIT measurement process. The correction methods were successfully verified with measurements under controlled conditions in a water-filled rain barrel, where a high phase accuracy of 0.8 mrad in the frequency range up to 10 kHz was achieved. The corrections were also applied to field EIT measurements made using a 25 m long EIT borehole chain with eight electrodes and an electrode separation of 1 m. The results of a 1D inversion of these measurements showed that the correction methods increased the measurement accuracy considerably. It was concluded that the proposed correction methods enlarge the bandwidth of the field EIT measurement system, and that accurate EIT measurements can now

  9. Estimation of time-series properties of gourd observed solar irradiance data using cloud properties derived from satellite observations

    Science.gov (United States)

    Watanabe, T.; Nohara, D.

    2017-12-01

    The shorter temporal scale variation in the downward solar irradiance at the ground level (DSI) is not understood well because researches in the shorter-scale variation in the DSI is based on the ground observation and ground observation stations are located coarsely. Use of dataset derived from satellite observation will overcome such defect. DSI data and MODIS cloud properties product are analyzed simultaneously. Three metrics: mean, standard deviation and sample entropy, are used to evaluate time-series properties of the DSI. Three metrics are computed from two-hours time-series centered at the observation time of MODIS over the ground observation stations. We apply the regression methods to design prediction models of each three metrics from cloud properties. The validation of the model accuracy show that mean and standard deviation are predicted with a higher degree of accuracy and that the accuracy of prediction of sample entropy, which represents the complexity of time-series, is not high. One of causes of lower prediction skill of sample entropy is the resolution of the MODIS cloud properties. Higher sample entropy is corresponding to the rapid fluctuation, which is caused by the small and unordered cloud. It seems that such clouds isn't retrieved well.

  10. Accuracy optimization of high-speed AFM measurements using Design of Experiments

    DEFF Research Database (Denmark)

    Tosello, Guido; Marinello, F.; Hansen, Hans Nørgaard

    2010-01-01

    Atomic Force Microscopy (AFM) is being increasingly employed in industrial micro/nano manufacturing applications and integrated into production lines. In order to achieve reliable process and product control at high measuring speed, instrument optimization is needed. Quantitative AFM measurement...... results are influenced by a number of scan settings parameters, defining topography sampling and measurement time: resolution (number of profiles and points per profile), scan range and direction, scanning force and speed. Such parameters are influencing lateral and vertical accuracy and, eventually......, the estimated dimensions of measured features. The definition of scan settings is based on a comprehensive optimization that targets maximization of information from collected data and minimization of measurement uncertainty and scan time. The Design of Experiments (DOE) technique is proposed and applied...

  11. The solar neighborhood. XXXIV. A search for planets orbiting nearby M dwarfs using astrometry

    International Nuclear Information System (INIS)

    Lurie, John C.; Henry, Todd J.; Ianna, Philip A.; Jao, Wei-Chun; Quinn, Samuel N.; Winters, Jennifer G.; Koerner, David W.; Riedel, Adric R.; Subasavage, John P.

    2014-01-01

    Astrometric measurements are presented for seven nearby stars with previously detected planets: six M dwarfs (GJ 317, GJ 667C, GJ 581, GJ 849, GJ 876, and GJ 1214) and one K dwarf (BD-10 -3166). Measurements are also presented for six additional nearby M dwarfs without known planets, but which are more favorable to astrometric detections of low mass companions, as well as three binary systems for which we provide astrometric orbit solutions. Observations have baselines of 3 to 13 years, and were made as part of the RECONS long-term astrometry and photometry program at the CTIO/SMARTS 0.9 m telescope. We provide trigonometric parallaxes and proper motions for all 16 systems, and perform an extensive analysis of the astrometric residuals to determine the minimum detectable companion mass for the 12 M dwarfs not having close stellar secondaries. For the six M dwarfs with known planets, we are not sensitive to planets, but can rule out the presence of all but the least massive brown dwarfs at periods of 2–12 years. For the six more astrometrically favorable M dwarfs, we conclude that none have brown dwarf companions, and are sensitive to companions with masses as low as 1 M Jup for periods longer than two years. In particular, we conclude that Proxima Centauri has no Jovian companions at orbital periods of 2–12 years. These results complement previously published M dwarf planet occurrence rates by providing astrometrically determined upper mass limits on potential super-Jupiter companions at orbits of two years and longer. As part of a continuing survey, these results are consistent with the paucity of super-Jupiter and brown dwarf companions we find among the over 250 red dwarfs within 25 pc observed longer than five years in our astrometric program.

  12. The solar neighborhood. XXXIV. A search for planets orbiting nearby M dwarfs using astrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lurie, John C. [Department of Astronomy, University of Washington, Seattle, WA 98195 (United States); Henry, Todd J.; Ianna, Philip A. [RECONS Institute, Chambersburg, PA 17201 (United States); Jao, Wei-Chun; Quinn, Samuel N.; Winters, Jennifer G. [Department of Physics and Astronomy, Georgia State University, Atlanta, GA 30302 (United States); Koerner, David W. [Department of Physics and Astronomy, Northern Arizona University, Flagstaff, AZ 86011 (United States); Riedel, Adric R. [Department of Astrophysics, American Museum of Natural History, New York, NY 10034 (United States); Subasavage, John P., E-mail: lurie@uw.edu [United States Naval Observatory, Flagstaff, AZ 86001 (United States)

    2014-11-01

    Astrometric measurements are presented for seven nearby stars with previously detected planets: six M dwarfs (GJ 317, GJ 667C, GJ 581, GJ 849, GJ 876, and GJ 1214) and one K dwarf (BD-10 -3166). Measurements are also presented for six additional nearby M dwarfs without known planets, but which are more favorable to astrometric detections of low mass companions, as well as three binary systems for which we provide astrometric orbit solutions. Observations have baselines of 3 to 13 years, and were made as part of the RECONS long-term astrometry and photometry program at the CTIO/SMARTS 0.9 m telescope. We provide trigonometric parallaxes and proper motions for all 16 systems, and perform an extensive analysis of the astrometric residuals to determine the minimum detectable companion mass for the 12 M dwarfs not having close stellar secondaries. For the six M dwarfs with known planets, we are not sensitive to planets, but can rule out the presence of all but the least massive brown dwarfs at periods of 2–12 years. For the six more astrometrically favorable M dwarfs, we conclude that none have brown dwarf companions, and are sensitive to companions with masses as low as 1 M{sub Jup} for periods longer than two years. In particular, we conclude that Proxima Centauri has no Jovian companions at orbital periods of 2–12 years. These results complement previously published M dwarf planet occurrence rates by providing astrometrically determined upper mass limits on potential super-Jupiter companions at orbits of two years and longer. As part of a continuing survey, these results are consistent with the paucity of super-Jupiter and brown dwarf companions we find among the over 250 red dwarfs within 25 pc observed longer than five years in our astrometric program.

  13. Accuracy of plain films, and the effect of experience, in the assessment of ankle effusions

    International Nuclear Information System (INIS)

    Karchevsky, Michael; Schweitzer, Mark E.

    2004-01-01

    To investigate the accuracy of plain radiographs, and the effect of observer experience, in the assessment of ankle effusions compared with an MRI gold standard. Anteroposterior (AP) and lateral radiographs of the ankle of 39 patients were evaluated by four observers, ranging from first-year radiology resident to an attending musculoskeletal radiologist. Observers independently graded the lateral films from 0 to5 at one sitting, and the AP films at a second sitting. All patients had an MRI scan performed within 48 h of the ankle radiographs, on which distention of the anterior recess was used as the gold standard for an effusion. Lateral radiographs had variable sensitivity (range 17 - 63%), but specificity (81-94%) was usually high. AP radiographs similarly had variable sensitivity (15-55%), but their specificity (63-75%) was surprisingly good. Overall, sensitivity and specificity were inversely proportional and more related to individual variability than experience (observer 1, 53% and 81%; observer 2, 17% and 94%; observer 3, 63% and 88%; observer 4, 21% and 94%); however, individual sensitivity and specificity were consistent between AP and lateral radiographs (observer 1, 53% and 81%, 50% and 65%; observer 2, 17% and 94%, 15% and 75%), observer 3, 63% and 88%, 55% and 63%; observer 4, 21% and 94%, 25% and 70%. Positive predictive value was reasonably good for lateral radiographs (range 75 - 86%); however, it was fairly low for AP radiographs (38-61%). Negative predictive value was low for both lateral (50-67%) and AP (47-58%) radiographs. Accuracy was low for both AP (45-59%) and lateral (53-74%) radiographs. As expected, individual accuracy was consistently higher for lateral radiographs than for AP radiographs (observer 1, 65% and 58%; observer 2, 53% and 45%; observer 3, 74% and 59%; observer 4, 54% and 48%). For the diagnosis of ankle effusions the overall accuracy of radiographs was surprisingly low. Quite surprisingly, the diagnosis of effusions on AP

  14. Social Power Increases Interoceptive Accuracy

    Directory of Open Access Journals (Sweden)

    Mehrad Moeini-Jazani

    2017-08-01

    Full Text Available Building on recent psychological research showing that power increases self-focused attention, we propose that having power increases accuracy in perception of bodily signals, a phenomenon known as interoceptive accuracy. Consistent with our proposition, participants in a high-power experimental condition outperformed those in the control and low-power conditions in the Schandry heartbeat-detection task. We demonstrate that the effect of power on interoceptive accuracy is not explained by participants’ physiological arousal, affective state, or general intention for accuracy. Rather, consistent with our reasoning that experiencing power shifts attentional resources inward, we show that the effect of power on interoceptive accuracy is dependent on individuals’ chronic tendency to focus on their internal sensations. Moreover, we demonstrate that individuals’ chronic sense of power also predicts interoceptive accuracy similar to, and independent of, how their situationally induced feeling of power does. We therefore provide further support on the relation between power and enhanced perception of bodily signals. Our findings offer a novel perspective–a psychophysiological account–on how power might affect judgments and behavior. We highlight and discuss some of these intriguing possibilities for future research.

  15. Methodology for GPS Synchronization Evaluation with High Accuracy

    OpenAIRE

    Li Zan; Braun Torsten; Dimitrova Desislava

    2015-01-01

    Clock synchronization in the order of nanoseconds is one of the critical factors for time based localization. Currently used time synchronization methods are developed for the more relaxed needs of network operation. Their usability for positioning should be carefully evaluated. In this paper we are particularly interested in GPS based time synchronization. To judge its usability for localization we need a method that can evaluate the achieved time synchronization with nanosecond accuracy. Ou...

  16. Methodology for GPS Synchronization Evaluation with High Accuracy

    OpenAIRE

    Li, Zan; Braun, Torsten; Dimitrova, Desislava Cvetanova

    2015-01-01

    Clock synchronization in the order of nanoseconds is one of the critical factors for time-based localization. Currently used time synchronization methods are developed for the more relaxed needs of network operation. Their usability for positioning should be carefully evaluated. In this paper, we are particularly interested in GPS-based time synchronization. To judge its usability for localization we need a method that can evaluate the achieved time synchronization with nanosecond accuracy. O...

  17. A high-accuracy optical linear algebra processor for finite element applications

    Science.gov (United States)

    Casasent, D.; Taylor, B. K.

    1984-01-01

    Optical linear processors are computationally efficient computers for solving matrix-matrix and matrix-vector oriented problems. Optical system errors limit their dynamic range to 30-40 dB, which limits their accuray to 9-12 bits. Large problems, such as the finite element problem in structural mechanics (with tens or hundreds of thousands of variables) which can exploit the speed of optical processors, require the 32 bit accuracy obtainable from digital machines. To obtain this required 32 bit accuracy with an optical processor, the data can be digitally encoded, thereby reducing the dynamic range requirements of the optical system (i.e., decreasing the effect of optical errors on the data) while providing increased accuracy. This report describes a new digitally encoded optical linear algebra processor architecture for solving finite element and banded matrix-vector problems. A linear static plate bending case study is described which quantities the processor requirements. Multiplication by digital convolution is explained, and the digitally encoded optical processor architecture is advanced.

  18. Reconciling Optical and Radio Observations of the Binary Millisecond Pulsar PSR J1640+2224

    Science.gov (United States)

    Vigeland, Sarah J.; Deller, Adam T.; Kaplan, David L.; Istrate, Alina G.; Stappers, Benjamin W.; Tauris, Thomas M.

    2018-03-01

    Previous optical and radio observations of the binary millisecond pulsar PSR J1640+2224 have come to inconsistent conclusions about the identity of its companion, with some observations suggesting that the companion is a low-mass helium-core (He-core) white dwarf (WD), while others indicate that it is most likely a high-mass carbon–oxygen (CO) WD. Binary evolution models predict PSR J1640+2224 most likely formed in a low-mass X-ray binary based on the pulsar’s short spin period and long-period, low-eccentricity orbit, in which case its companion should be a He-core WD with mass about 0.35–0.39 M ⊙, depending on metallicity. If instead it is a CO WD, it would suggest that the system has an unusual formation history. In this paper we present the first astrometric parallax measurement for this system from observations made with the Very Long Baseline Array (VLBA), from which we determine the distance to be {1520}-150+170 {pc}. We use this distance and a reanalysis of archival optical observations originally taken in 1995 with the Wide Field Planetary Camera 2 on the Hubble Space Telescope (HST) to measure the WD’s mass. We also incorporate improvements in calibration, extinction model, and WD cooling models. We find that the existing observations are not sufficient to tightly constrain the companion mass, but we conclude the WD mass is >0.4 M ⊙ with >90% confidence. The limiting factor in our analysis is the low signal-to-noise ratio of the original HST observations.

  19. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. I. INSTRUMENT DESCRIPTION AND FIRST RESULTS

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Veillette, Daniel R.; Shah, Sagar C.; O'Rielly, Grant V.; Baena Galle, Roberto; Van Altena, William F.

    2009-01-01

    First results of a new speckle imaging system, the Differential Speckle Survey Instrument, are reported. The instrument is designed to take speckle data in two filters simultaneously with two independent CCD imagers. This feature results in three advantages over other speckle cameras: (1) twice as many frames can be obtained in the same observation time which can increase the signal-to-noise ratio for astrometric measurements, (2) component colors can be derived from a single observation, and (3) the two colors give substantial leverage over atmospheric dispersion, allowing for subdiffraction-limited separations to be measured reliably. Fifty-four observations are reported from the first use of the instrument at the Wisconsin-Indiana-Yale-NOAO 3.5 m Telescope 9 The WIYN Observatory is a joint facility of the University of Wisconsin-Madison, Indiana University, Yale University, and the National Optical Astronomy Observatories. in 2008 September, including seven components resolved for the first time. These observations are used to judge the basic capabilities of the instrument.

  20. High-accuracy measurement and compensation of grating line-density error in a tiled-grating compressor

    Science.gov (United States)

    Zhao, Dan; Wang, Xiao; Mu, Jie; Li, Zhilin; Zuo, Yanlei; Zhou, Song; Zhou, Kainan; Zeng, Xiaoming; Su, Jingqin; Zhu, Qihua

    2017-02-01

    The grating tiling technology is one of the most effective means to increase the aperture of the gratings. The line-density error (LDE) between sub-gratings will degrade the performance of the tiling gratings, high accuracy measurement and compensation of the LDE are of significance to improve the output pulses characteristics of the tiled-grating compressor. In this paper, the influence of LDE on the output pulses of the tiled-grating compressor is quantitatively analyzed by means of numerical simulation, the output beams drift and output pulses broadening resulting from the LDE are presented. Based on the numerical results we propose a compensation method to reduce the degradations of the tiled grating compressor by applying angular tilt error and longitudinal piston error at the same time. Moreover, a monitoring system is setup to measure the LDE between sub-gratings accurately and the dispersion variation due to the LDE is also demonstrated based on spatial-spectral interference. In this way, we can realize high-accuracy measurement and compensation of the LDE, and this would provide an efficient way to guide the adjustment of the tiling gratings.

  1. Accuracy of cell calculation methods used for analysis of high conversion light water reactor lattice

    International Nuclear Information System (INIS)

    Jeong, Chang-Joon; Okumura, Keisuke; Ishiguro, Yukio; Tanaka, Ken-ichi

    1990-01-01

    Validation tests were made for the accuracy of cell calculation methods used in analyses of tight lattices of a mixed-oxide (MOX) fuel core in a high conversion light water reactor (HCLWR). A series of cell calculations was carried out for the lattices referred from an international HCLWR benchmark comparison, with emphasis placed on the resonance calculation methods; the NR, IR approximations, the collision probability method with ultra-fine energy group. Verification was also performed for the geometrical modelling; a hexagonal/cylindrical cell, and the boundary condition; mirror/white reflection. In the calculations, important reactor physics parameters, such as the neutron multiplication factor, the conversion ratio and the void coefficient, were evaluated using the above methods for various HCLWR lattices with different moderator to fuel volume ratios, fuel materials and fissile plutonium enrichments. The calculated results were compared with each other, and the accuracy and applicability of each method were clarified by comparison with continuous energy Monte Carlo calculations. It was verified that the accuracy of the IR approximation became worse when the neutron spectrum became harder. It was also concluded that the cylindrical cell model with the white boundary condition was not so suitable for MOX fuelled lattices, as for UO 2 fuelled lattices. (author)

  2. The solar neighborhood. XXXI. Discovery of an unusual red+white dwarf binary at ∼25 pc via astrometry and UV imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jao, Wei-Chun; Henry, Todd J.; Winters, Jennifer G.; Gies, Douglas R. [Department of Physics and Astronomy, Georgia State University, Atlanta, GA 30302 (United States); Subasavage, John P. [US Naval Observatory, Flagstaff Station, 10391 West Naval Observatory Road, Flagstaff, AZ 86001 (United States); Riedel, Adric R. [Department of Physics and Astronomy, Hunter College, 695 Park Avenue, New York, NY 10065 (United States); Ianna, Philip A., E-mail: jao@chara.gsu.edu, E-mail: thenry@chara.gsu.edu, E-mail: winters@chara.gsu.edu, E-mail: gies@chara.gsu.edu, E-mail: jsubasavage@nofs.navy.mil, E-mail: ar494@hunter.cuny.edu, E-mail: philianna3@gmail.com [Department of Astronomy, University of Virginia, Charlottesville, VA 22904-4325 (United States)

    2014-01-01

    We report the discovery of a nearby M5.0V dwarf at 24.6 pc, SCR 1848–6855, that is orbited by an unusual companion causing an astrometric perturbation of more than 200 mas. This is by far the largest perturbation found to date among more than 700 targets observed during our long-term astrometry/photometry program at the CTIO 0.9 m telescope. We present here a suite of astrometric, photometric, and spectroscopic observations of this high proper motion (∼1.''3 yr{sup –1}) system in an effort to reveal the nature of this unusual binary. The measured near-UV and optical U band fluxes exceed those expected for comparable M5.0V stars, and excess flux is also detected in the spectral range 4000-7000 Å. The elusive companion has been detected in HST-STIS+MAMA images at 1820 Å and 2700 Å, and our analysis shows that it is probably a rare, cool, white dwarf with T = 4600-5500 K. Given the long-term astrometric coverage, the prospects for an accurate mass determination are excellent, although as yet we can only provide limits on the unusual companion's mass.

  3. Use of a Differential Observing Response to Expand Restricted Stimulus Control

    Science.gov (United States)

    Walpole, Carrie Wallace; Roscoe, Eileen M.; Dube, William V.

    2007-01-01

    This study extends previous work on the use of differential observing responses (DOR) to remediate atypically restricted stimulus control. A participant with autism had high matching-to-sample accuracy scores with printed words that had no letters in common (e.g., "cat," "lid," "bug") but poor accuracy with words that had two letters in common…

  4. Cost-effective improvements of a rotating platform by integration of a high-accuracy inclinometer and encoders for attitude evaluation

    International Nuclear Information System (INIS)

    Wen, Chenyang; He, Shengyang; Hu, Peida; Bu, Changgen

    2017-01-01

    Attitude heading reference systems (AHRSs) based on micro-electromechanical system (MEMS) inertial sensors are widely used because of their low cost, light weight, and low power. However, low-cost AHRSs suffer from large inertial sensor errors. Therefore, experimental performance evaluation of MEMS-based AHRSs after system implementation is necessary. High-accuracy turntables can be used to verify the performance of MEMS-based AHRSs indoors, but they are expensive and unsuitable for outdoor tests. This study developed a low-cost two-axis rotating platform for indoor and outdoor attitude determination. A high-accuracy inclinometer and encoders were integrated into the platform to improve the achievable attitude test accuracy. An attitude error compensation method was proposed to calibrate the initial attitude errors caused by the movements and misalignment angles of the platform. The proposed attitude error determination method was examined through rotating experiments, which showed that the standard deviations of the pitch and roll errors were 0.050° and 0.090°, respectively. The pitch and roll errors both decreased to 0.024° when the proposed attitude error determination method was used. This decrease validates the effectiveness of the compensation method. Experimental results demonstrated that the integration of the inclinometer and encoders improved the performance of the low-cost, two-axis, rotating platform in terms of attitude accuracy. (paper)

  5. Accuracy assessment of high-rate GPS measurements for seismology

    Science.gov (United States)

    Elosegui, P.; Davis, J. L.; Ekström, G.

    2007-12-01

    Analysis of GPS measurements with a controlled laboratory system, built to simulate the ground motions caused by tectonic earthquakes and other transient geophysical signals such as glacial earthquakes, enables us to assess the technique of high-rate GPS. The root-mean-square (rms) position error of this system when undergoing realistic simulated seismic motions is 0.05~mm, with maximum position errors of 0.1~mm, thus providing "ground truth" GPS displacements. We have acquired an extensive set of high-rate GPS measurements while inducing seismic motions on a GPS antenna mounted on this system with a temporal spectrum similar to real seismic events. We found that, for a particular 15-min-long test event, the rms error of the 1-Hz GPS position estimates was 2.5~mm, with maximum position errors of 10~mm, and the error spectrum of the GPS estimates was approximately flicker noise. These results may however represent a best-case scenario since they were obtained over a short (~10~m) baseline, thereby greatly mitigating baseline-dependent errors, and when the number and distribution of satellites on the sky was good. For example, we have determined that the rms error can increase by a factor of 2--3 as the GPS constellation changes throughout the day, with an average value of 3.5~mm for eight identical, hourly-spaced, consecutive test events. The rms error also increases with increasing baseline, as one would expect, with an average rms error for a ~1400~km baseline of 9~mm. We will present an assessment of the accuracy of high-rate GPS based on these measurements, discuss the implications of this study for seismology, and describe new applications in glaciology.

  6. 100% classification accuracy considered harmful: the normalized information transfer factor explains the accuracy paradox.

    Directory of Open Access Journals (Sweden)

    Francisco J Valverde-Albacete

    Full Text Available The most widely spread measure of performance, accuracy, suffers from a paradox: predictive models with a given level of accuracy may have greater predictive power than models with higher accuracy. Despite optimizing classification error rate, high accuracy models may fail to capture crucial information transfer in the classification task. We present evidence of this behavior by means of a combinatorial analysis where every possible contingency matrix of 2, 3 and 4 classes classifiers are depicted on the entropy triangle, a more reliable information-theoretic tool for classification assessment. Motivated by this, we develop from first principles a measure of classification performance that takes into consideration the information learned by classifiers. We are then able to obtain the entropy-modulated accuracy (EMA, a pessimistic estimate of the expected accuracy with the influence of the input distribution factored out, and the normalized information transfer factor (NIT, a measure of how efficient is the transmission of information from the input to the output set of classes. The EMA is a more natural measure of classification performance than accuracy when the heuristic to maximize is the transfer of information through the classifier instead of classification error count. The NIT factor measures the effectiveness of the learning process in classifiers and also makes it harder for them to "cheat" using techniques like specialization, while also promoting the interpretability of results. Their use is demonstrated in a mind reading task competition that aims at decoding the identity of a video stimulus based on magnetoencephalography recordings. We show how the EMA and the NIT factor reject rankings based in accuracy, choosing more meaningful and interpretable classifiers.

  7. First light for GRAVITY: Phase referencing optical interferometry for the Very Large Telescope Interferometer

    Science.gov (United States)

    Gravity Collaboration; Abuter, R.; Accardo, M.; Amorim, A.; Anugu, N.; Ávila, G.; Azouaoui, N.; Benisty, M.; Berger, J. P.; Blind, N.; Bonnet, H.; Bourget, P.; Brandner, W.; Brast, R.; Buron, A.; Burtscher, L.; Cassaing, F.; Chapron, F.; Choquet, É.; Clénet, Y.; Collin, C.; Coudé Du Foresto, V.; de Wit, W.; de Zeeuw, P. T.; Deen, C.; Delplancke-Ströbele, F.; Dembet, R.; Derie, F.; Dexter, J.; Duvert, G.; Ebert, M.; Eckart, A.; Eisenhauer, F.; Esselborn, M.; Fédou, P.; Finger, G.; Garcia, P.; Garcia Dabo, C. E.; Garcia Lopez, R.; Gendron, E.; Genzel, R.; Gillessen, S.; Gonte, F.; Gordo, P.; Grould, M.; Grözinger, U.; Guieu, S.; Haguenauer, P.; Hans, O.; Haubois, X.; Haug, M.; Haussmann, F.; Henning, Th.; Hippler, S.; Horrobin, M.; Huber, A.; Hubert, Z.; Hubin, N.; Hummel, C. A.; Jakob, G.; Janssen, A.; Jochum, L.; Jocou, L.; Kaufer, A.; Kellner, S.; Kendrew, S.; Kern, L.; Kervella, P.; Kiekebusch, M.; Klein, R.; Kok, Y.; Kolb, J.; Kulas, M.; Lacour, S.; Lapeyrère, V.; Lazareff, B.; Le Bouquin, J.-B.; Lèna, P.; Lenzen, R.; Lévêque, S.; Lippa, M.; Magnard, Y.; Mehrgan, L.; Mellein, M.; Mérand, A.; Moreno-Ventas, J.; Moulin, T.; Müller, E.; Müller, F.; Neumann, U.; Oberti, S.; Ott, T.; Pallanca, L.; Panduro, J.; Pasquini, L.; Paumard, T.; Percheron, I.; Perraut, K.; Perrin, G.; Pflüger, A.; Pfuhl, O.; Phan Duc, T.; Plewa, P. M.; Popovic, D.; Rabien, S.; Ramírez, A.; Ramos, J.; Rau, C.; Riquelme, M.; Rohloff, R.-R.; Rousset, G.; Sanchez-Bermudez, J.; Scheithauer, S.; Schöller, M.; Schuhler, N.; Spyromilio, J.; Straubmeier, C.; Sturm, E.; Suarez, M.; Tristram, K. R. W.; Ventura, N.; Vincent, F.; Waisberg, I.; Wank, I.; Weber, J.; Wieprecht, E.; Wiest, M.; Wiezorrek, E.; Wittkowski, M.; Woillez, J.; Wolff, B.; Yazici, S.; Ziegler, D.; Zins, G.

    2017-06-01

    GRAVITY is a new instrument to coherently combine the light of the European Southern Observatory Very Large Telescope Interferometer to form a telescope with an equivalent 130 m diameter angular resolution and a collecting area of 200 m2. The instrument comprises fiber fed integrated optics beam combination, high resolution spectroscopy, built-in beam analysis and control, near-infrared wavefront sensing, phase-tracking, dual-beam operation, and laser metrology. GRAVITY opens up to optical/infrared interferometry the techniques of phase referenced imaging and narrow angle astrometry, in many aspects following the concepts of radio interferometry. This article gives an overview of GRAVITY and reports on the performance and the first astronomical observations during commissioning in 2015/16. We demonstrate phase-tracking on stars as faint as mK ≈ 10 mag, phase-referenced interferometry of objects fainter than mK ≈ 15 mag with a limiting magnitude of mK ≈ 17 mag, minute long coherent integrations, a visibility accuracy of better than 0.25%, and spectro-differential phase and closure phase accuracy better than 0.5°, corresponding to a differential astrometric precision of better than ten microarcseconds (μas). The dual-beam astrometry, measuring the phase difference of two objects with laser metrology, is still under commissioning. First observations show residuals as low as 50 μas when following objects over several months. We illustrate the instrument performance with the observations of archetypical objects for the different instrument modes. Examples include the Galactic center supermassive black hole and its fast orbiting star S2 for phase referenced dual-beam observations and infrared wavefront sensing, the high mass X-ray binary BP Cru and the active galactic nucleus of PDS 456 for a few μas spectro-differential astrometry, the T Tauri star S CrA for a spectro-differential visibility analysis, ξ Tel and 24 Cap for high accuracy visibility observations

  8. Innovative High-Accuracy Lidar Bathymetric Technique for the Frequent Measurement of River Systems

    Science.gov (United States)

    Gisler, A.; Crowley, G.; Thayer, J. P.; Thompson, G. S.; Barton-Grimley, R. A.

    2015-12-01

    Lidar (light detection and ranging) provides absolute depth and topographic mapping capability compared to other remote sensing methods, which is useful for mapping rapidly changing environments such as riverine systems. Effectiveness of current lidar bathymetric systems is limited by the difficulty in unambiguously identifying backscattered lidar signals from the water surface versus the bottom, limiting their depth resolution to 0.3-0.5 m. Additionally these are large, bulky systems that are constrained to expensive aircraft-mounted platforms and use waveform-processing techniques requiring substantial computation time. These restrictions are prohibitive for many potential users. A novel lidar device has been developed that allows for non-contact measurements of water depth down to 1 cm with an accuracy and precision of shallow to deep water allowing for shoreline charting, measuring water volume, mapping bottom topology, and identifying submerged objects. The scalability of the technique opens up the ability for handheld or UAS-mounted lidar bathymetric systems, which provides for potential applications currently unavailable to the community. The high laser pulse repetition rate allows for very fine horizontal resolution while the photon-counting technique permits real-time depth measurement and object detection. The enhanced measurement capability, portability, scalability, and relatively low-cost creates the opportunity to perform frequent high-accuracy monitoring and measuring of aquatic environments which is crucial for understanding how rivers evolve over many timescales. Results from recent campaigns measuring water depth in flowing creeks and murky ponds will be presented which demonstrate that the method is not limited by rough water surfaces and can map underwater topology through moderately turbid water.

  9. Accuracy assessment of high frequency 3D ultrasound for digital impression-taking of prepared teeth

    Science.gov (United States)

    Heger, Stefan; Vollborn, Thorsten; Tinschert, Joachim; Wolfart, Stefan; Radermacher, Klaus

    2013-03-01

    Silicone based impression-taking of prepared teeth followed by plaster casting is well-established but potentially less reliable, error-prone and inefficient, particularly in combination with emerging techniques like computer aided design and manufacturing (CAD/CAM) of dental prosthesis. Intra-oral optical scanners for digital impression-taking have been introduced but until now some drawbacks still exist. Because optical waves can hardly penetrate liquids or soft-tissues, sub-gingival preparations still need to be uncovered invasively prior to scanning. High frequency ultrasound (HFUS) based micro-scanning has been recently investigated as an alternative to optical intra-oral scanning. Ultrasound is less sensitive against oral fluids and in principal able to penetrate gingiva without invasively exposing of sub-gingival preparations. Nevertheless, spatial resolution as well as digitization accuracy of an ultrasound based micro-scanning system remains a critical parameter because the ultrasound wavelength in water-like media such as gingiva is typically smaller than that of optical waves. In this contribution, the in-vitro accuracy of ultrasound based micro-scanning for tooth geometry reconstruction is being investigated and compared to its extra-oral optical counterpart. In order to increase the spatial resolution of the system, 2nd harmonic frequencies from a mechanically driven focused single element transducer were separated and corresponding 3D surface models were calculated for both fundamentals and 2nd harmonics. Measurements on phantoms, model teeth and human teeth were carried out for evaluation of spatial resolution and surface detection accuracy. Comparison of optical and ultrasound digital impression taking indicate that, in terms of accuracy, ultrasound based tooth digitization can be an alternative for optical impression-taking.

  10. Accuracy of applicator tip reconstruction in MRI-guided interstitial 192Ir-high-dose-rate brachytherapy of liver tumors

    International Nuclear Information System (INIS)

    Wybranski, Christian; Eberhardt, Benjamin; Fischbach, Katharina; Fischbach, Frank; Walke, Mathias; Hass, Peter; Röhl, Friedrich-Wilhelm; Kosiek, Ortrud; Kaiser, Mandy; Pech, Maciej; Lüdemann, Lutz; Ricke, Jens

    2015-01-01

    Background and purpose: To evaluate the reconstruction accuracy of brachytherapy (BT) applicators tips in vitro and in vivo in MRI-guided 192 Ir-high-dose-rate (HDR)-BT of inoperable liver tumors. Materials and methods: Reconstruction accuracy of plastic BT applicators, visualized by nitinol inserts, was assessed in MRI phantom measurements and in MRI 192 Ir-HDR-BT treatment planning datasets of 45 patients employing CT co-registration and vector decomposition. Conspicuity, short-term dislocation, and reconstruction errors were assessed in the clinical data. The clinical effect of applicator reconstruction accuracy was determined in follow-up MRI data. Results: Applicator reconstruction accuracy was 1.6 ± 0.5 mm in the phantom measurements. In the clinical MRI datasets applicator conspicuity was rated good/optimal in ⩾72% of cases. 16/129 applicators showed not time dependent deviation in between MRI/CT acquisition (p > 0.1). Reconstruction accuracy was 5.5 ± 2.8 mm, and the average image co-registration error was 3.1 ± 0.9 mm. Vector decomposition revealed no preferred direction of reconstruction errors. In the follow-up data deviation of planned dose distribution and irradiation effect was 6.9 ± 3.3 mm matching the mean co-registration error (6.5 ± 2.5 mm; p > 0.1). Conclusion: Applicator reconstruction accuracy in vitro conforms to AAPM TG 56 standard. Nitinol-inserts are feasible for applicator visualization and yield good conspicuity in MRI treatment planning data. No preferred direction of reconstruction errors were found in vivo

  11. STTR Phase I: Low-Cost, High-Accuracy, Whole-Building Carbon Dioxide Monitoring for Demand Control Ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Hallstrom, Jason; Ni, Zheng Richard

    2018-05-15

    This STTR Phase I project assessed the feasibility of a new CO2 sensing system optimized for low-cost, high-accuracy, whole-building monitoring for use in demand control ventilation. The focus was on the development of a wireless networking platform and associated firmware to provide signal conditioning and conversion, fault- and disruptiontolerant networking, and multi-hop routing at building scales to avoid wiring costs. Early exploration of a bridge (or “gateway”) to direct digital control services was also explored. Results of the project contributed to an improved understanding of a new electrochemical sensor for monitoring indoor CO2 concentrations, as well as the electronics and networking infrastructure required to deploy those sensors at building scales. New knowledge was acquired concerning the sensor’s accuracy, environmental response, and failure modes, and the acquisition electronics required to achieve accuracy over a wide range of CO2 concentrations. The project demonstrated that the new sensor offers repeatable correspondence with commercial optical sensors, with supporting electronics that offer gain accuracy within 0.5%, and acquisition accuracy within 1.5% across three orders of magnitude variation in generated current. Considering production, installation, and maintenance costs, the technology presents a foundation for achieving whole-building CO2 sensing at a price point below $0.066 / sq-ft – meeting economic feasibility criteria established by the Department of Energy. The technology developed under this award addresses obstacles on the critical path to enabling whole-building CO2 sensing and demand control ventilation in commercial retrofits, small commercial buildings, residential complexes, and other highpotential structures that have been slow to adopt these technologies. It presents an opportunity to significantly reduce energy use throughout the United States a

  12. Climate Change Accuracy: Requirements and Economic Value

    Science.gov (United States)

    Wielicki, B. A.; Cooke, R.; Mlynczak, M. G.; Lukashin, C.; Thome, K. J.; Baize, R. R.

    2014-12-01

    Higher than normal accuracy is required to rigorously observe decadal climate change. But what level is needed? How can this be quantified? This presentation will summarize a new more rigorous and quantitative approach to determining the required accuracy for climate change observations (Wielicki et al., 2013, BAMS). Most current global satellite observations cannot meet this accuracy level. A proposed new satellite mission to resolve this challenge is CLARREO (Climate Absolute Radiance and Refractivity Observatory). CLARREO is designed to achieve advances of a factor of 10 for reflected solar spectra and a factor of 3 to 5 for thermal infrared spectra (Wielicki et al., Oct. 2013 BAMS). The CLARREO spectrometers are designed to serve as SI traceable benchmarks for the Global Satellite Intercalibration System (GSICS) and to greatly improve the utility of a wide range of LEO and GEO infrared and reflected solar passive satellite sensors for climate change observations (e.g. CERES, MODIS, VIIIRS, CrIS, IASI, Landsat, SPOT, etc). Providing more accurate decadal change trends can in turn lead to more rapid narrowing of key climate science uncertainties such as cloud feedback and climate sensitivity. A study has been carried out to quantify the economic benefits of such an advance as part of a rigorous and complete climate observing system. The study concludes that the economic value is $12 Trillion U.S. dollars in Net Present Value for a nominal discount rate of 3% (Cooke et al. 2013, J. Env. Sys. Dec.). A brief summary of these two studies and their implications for the future of climate science will be presented.

  13. The accuracy of prehospital diagnosis of acute cerebrovascular accidents: an observational study

    OpenAIRE

    Karli?ski, Micha?; Gluszkiewicz, Marcin; Cz?onkowska, Anna

    2015-01-01

    Introduction Time to treatment is the key factor in stroke care. Although the initial medical assessment is usually made by a non-neurologist or a paramedic, it should ensure correct identification of all acute cerebrovascular accidents (CVAs). Our aim was to evaluate the accuracy of the physician-made prehospital diagnosis of acute CVA in patients referred directly to the neurological emergency department (ED), and to identify conditions mimicking CVAs. Material and methods This observationa...

  14. SPECKLE OBSERVATIONS OF BINARY STARS WITH THE WIYN TELESCOPE. VII. MEASURES DURING 2008-2009

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Bahi, Lizzie Anne P.; Gaulin, Joseph R.; Howell, Steve B.; Sherry, William H.; Baena Gallé, Roberto; Van Altena, William F.

    2012-01-01

    Five hundred thirty-one speckle measures of binary stars are reported. These data were taken mainly during the period 2008 June through 2009 October at the WIYN 3.5 m Telescope at Kitt Peak and represent the last data set of single-filter speckle observations taken in the WIYN speckle program prior to the use of the current two-channel speckle camera. The astrometric and photometric precision of these observations is consistent with previous papers in this series: we obtain a typical linear measurement uncertainty of approximately 2.5 mas, and the magnitude differences reported have typical uncertainties in the range of 0.1-0.14 mag. In combination with measures already in the literature, the data presented here permit the revision of the orbit of A 1634AB (= HIP 76041) and the first determination of visual orbital elements for HDS 1895 (= HIP 65982).

  15. Astrometric Calibration and Performance of the Dark Energy Camera

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, G. M.; Armstrong, R.; Plazas, A. A.; Walker, A. R.; Abbott, T. M. C.; Allam, S.; Bechtol, K.; Benoit-Lévy, A.; Brooks, D.; Burke, D. L.; Rosell, A. Carnero; Kind, M. Carrasco; Carretero, J.; Cunha, C. E.; Costa, L. N. da; DePoy, D. L.; Desai, S.; Diehl, H. T.; Eifler, T. F.; Fernandez, E.; Fosalba, P.; Frieman, J.; García-Bellido, J.; Gerdes, D. W.; Gruen, D.; Gruendl, R. A.; Gschwend, J.; Gutierrez, G.; Honscheid, K.; James, D. J.; Kent, S.; Krause, E.; Kuehn, K.; Kuropatkin, N.; Li, T. S.; Maia, M. A. G.; March, M.; Marshall, J. L.; Menanteau, F.; Miquel, R.; Ogando, R. L. C.; Reil, K.; Roodman, A.; Rykoff, E. S.; Sanchez, E.; Scarpine, V.; Schindler, R.; Schubnell, M.; Sevilla-Noarbe, I.; Smith, M.; Smith, R. C.; Soares-Santos, M.; Sobreira, F.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.

    2017-05-30

    We characterize the variation in photometric response of the Dark Energy Camera (DECam) across its 520~Mpix science array during 4 years of operation. These variations are measured using high signal-to-noise aperture photometry of $>10^7$ stellar images in thousands of exposures of a few selected fields, with the telescope dithered to move the sources around the array. A calibration procedure based on these results brings the RMS variation in aperture magnitudes of bright stars on cloudless nights down to 2--3 mmag, with <1 mmag of correlated photometric errors for stars separated by $\\ge20$". On cloudless nights, any departures of the exposure zeropoints from a secant airmass law exceeding >1 mmag are plausibly attributable to spatial/temporal variations in aperture corrections. These variations can be inferred and corrected by measuring the fraction of stellar light in an annulus between 6" and 8" diameter. Key elements of this calibration include: correction of amplifier nonlinearities; distinguishing pixel-area variations and stray light from quantum-efficiency variations in the flat fields; field-dependent color corrections; and the use of an aperture-correction proxy. The DECam response pattern across the 2-degree field drifts over months by up to $\\pm7$ mmag, in a nearly-wavelength-independent low-order pattern. We find no fundamental barriers to pushing global photometric calibrations toward mmag accuracy.

  16. The Future of Astrometry in Space

    Directory of Open Access Journals (Sweden)

    Antonella Vallenari

    2018-04-01

    Full Text Available This contribution focuses on the importance of astrometry and on its future developments. Over the centuries astrometry has greatly contributed to the advance of the knowledge of the Universe. Nowadays a major breakthrough is on the way due to astrometric sky surveys from space. ESA space missions Hipparcos first and then Gaia point out the outstanding contribution that space astrometry can provide to our knowledge in many fields of astrophysics, going from the Milky Way formation and evolution, to stellar astrophysics, extra-galactic astrophysics, and fundamental physics. We briefly outline the properties of Gaia first and second data release, and the accuracies expected end-of-mission. The next big advance in space astrometry would be either to improve the astrometric accuracy of one order of magnitude, or to move to a different wavelength domain. While both options have the potential to bring us in a new era of discovery, they have to face enormous issues. We summarize the future directions in space astrometry that are proposed or under investigation by the scientific community, their main challenges and the expected outcome.

  17. A study on low-cost, high-accuracy, and real-time stereo vision algorithms for UAV power line inspection

    Science.gov (United States)

    Wang, Hongyu; Zhang, Baomin; Zhao, Xun; Li, Cong; Lu, Cunyue

    2018-04-01

    Conventional stereo vision algorithms suffer from high levels of hardware resource utilization due to algorithm complexity, or poor levels of accuracy caused by inadequacies in the matching algorithm. To address these issues, we have proposed a stereo range-finding technique that produces an excellent balance between cost, matching accuracy and real-time performance, for power line inspection using UAV. This was achieved through the introduction of a special image preprocessing algorithm and a weighted local stereo matching algorithm, as well as the design of a corresponding hardware architecture. Stereo vision systems based on this technique have a lower level of resource usage and also a higher level of matching accuracy following hardware acceleration. To validate the effectiveness of our technique, a stereo vision system based on our improved algorithms were implemented using the Spartan 6 FPGA. In comparative experiments, it was shown that the system using the improved algorithms outperformed the system based on the unimproved algorithms, in terms of resource utilization and matching accuracy. In particular, Block RAM usage was reduced by 19%, and the improved system was also able to output range-finding data in real time.

  18. Interobserver variability and accuracy of high-definition endoscopic diagnosis for gastric intestinal metaplasia among experienced and inexperienced endoscopists.

    Science.gov (United States)

    Hyun, Yil Sik; Han, Dong Soo; Bae, Joong Ho; Park, Hye Sun; Eun, Chang Soo

    2013-05-01

    Accurate diagnosis of gastric intestinal metaplasia is important; however, conventional endoscopy is known to be an unreliable modality for diagnosing gastric intestinal metaplasia (IM). The aims of the study were to evaluate the interobserver variation in diagnosing IM by high-definition (HD) endoscopy and the diagnostic accuracy of this modality for IM among experienced and inexperienced endoscopists. Selected 50 cases, taken with HD endoscopy, were sent for a diagnostic inquiry of gastric IM through visual inspection to five experienced and five inexperienced endoscopists. The interobserver agreement between endoscopists was evaluated to verify the diagnostic reliability of HD endoscopy in diagnosing IM, and the diagnostic accuracy, sensitivity, and specificity were evaluated for validity of HD endoscopy in diagnosing IM. Interobserver agreement among the experienced endoscopists was "poor" (κ = 0.38) and it was also "poor" (κ = 0.33) among the inexperienced endoscopists. The diagnostic accuracy of the experienced endoscopists was superior to that of the inexperienced endoscopists (P = 0.003). Since diagnosis through visual inspection is unreliable in the diagnosis of IM, all suspicious areas for gastric IM should be considered to be biopsied. Furthermore, endoscopic experience and education are needed to raise the diagnostic accuracy of gastric IM.

  19. Modified sine bar device measures small angles with high accuracy

    Science.gov (United States)

    Thekaekara, M.

    1968-01-01

    Modified sine bar device measures small angles with enough accuracy to calibrate precision optical autocollimators. The sine bar is a massive bar of steel supported by two cylindrical rods at one end and one at the other.

  20. Systematic review of discharge coding accuracy

    Science.gov (United States)

    Burns, E.M.; Rigby, E.; Mamidanna, R.; Bottle, A.; Aylin, P.; Ziprin, P.; Faiz, O.D.

    2012-01-01

    Introduction Routinely collected data sets are increasingly used for research, financial reimbursement and health service planning. High quality data are necessary for reliable analysis. This study aims to assess the published accuracy of routinely collected data sets in Great Britain. Methods Systematic searches of the EMBASE, PUBMED, OVID and Cochrane databases were performed from 1989 to present using defined search terms. Included studies were those that compared routinely collected data sets with case or operative note review and those that compared routinely collected data with clinical registries. Results Thirty-two studies were included. Twenty-five studies compared routinely collected data with case or operation notes. Seven studies compared routinely collected data with clinical registries. The overall median accuracy (routinely collected data sets versus case notes) was 83.2% (IQR: 67.3–92.1%). The median diagnostic accuracy was 80.3% (IQR: 63.3–94.1%) with a median procedure accuracy of 84.2% (IQR: 68.7–88.7%). There was considerable variation in accuracy rates between studies (50.5–97.8%). Since the 2002 introduction of Payment by Results, accuracy has improved in some respects, for example primary diagnoses accuracy has improved from 73.8% (IQR: 59.3–92.1%) to 96.0% (IQR: 89.3–96.3), P= 0.020. Conclusion Accuracy rates are improving. Current levels of reported accuracy suggest that routinely collected data are sufficiently robust to support their use for research and managerial decision-making. PMID:21795302

  1. Accuracy Assessment and Analysis for GPT2

    Directory of Open Access Journals (Sweden)

    YAO Yibin

    2015-07-01

    Full Text Available GPT(global pressure and temperature is a global empirical model usually used to provide temperature and pressure for the determination of tropospheric delay, there are some weakness to GPT, these have been improved with a new empirical model named GPT2, which not only improves the accuracy of temperature and pressure, but also provides specific humidity, water vapor pressure, mapping function coefficients and other tropospheric parameters, and no accuracy analysis of GPT2 has been made until now. In this paper high-precision meteorological data from ECWMF and NOAA were used to test and analyze the accuracy of temperature, pressure and water vapor pressure expressed by GPT2, testing results show that the mean Bias of temperature is -0.59℃, average RMS is 3.82℃; absolute value of average Bias of pressure and water vapor pressure are less than 1 mb, GPT2 pressure has average RMS of 7 mb, and water vapor pressure no more than 3 mb, accuracy is different in different latitudes, all of them have obvious seasonality. In conclusion, GPT2 model has high accuracy and stability on global scale.

  2. Atypical self-focus effect on interoceptive accuracy in anorexia nervosa

    Directory of Open Access Journals (Sweden)

    Olga Pollatos

    2016-09-01

    Full Text Available Background: Interoceptive abilities are known to be affected in anorexia nervosa (AN. Previous studies could show that private self-focus can enhance interoceptive accuracy (IAcc in healthy participants. As body dissatisfaction is high in AN, confrontation with bodily features such as the own face might have a directly opposed effect in AN. Whether patients with AN can benefit from self-focus in their IAcc and whether this pattern changes over the time-course of cognitive behavioral therapy was investigated in this study. Methods: 15 patients with AN from the Psychosomatic Clinic in Windach were assessed three times in the time course of a standardized cognitive-behavioral therapy. They were compared to 15 controls, recruited from Ulm University and tested in a comparable setting. Both groups performed the heartbeat perception task assessing interoceptive accuracy (IAcc under two conditions either enhancing (Self or decreasing (Other self-focused attention. Furthermore, body dissatisfaction was assessed by a subscale of the Eating Disorder Inventory 2. Results: Patients with AN scored higher in IAcc when watching others’ faces as compared to one’s own face while performing the heartbeat perception task. The opposite pattern was observed in controls. IAcc remained reduced in AN as compared to controls in the time-course of cognitive-behavioral therapy, while body-dissatisfaction improved in AN. High body dissatisfaction was related to poorer IAcc in the Self condition. Conclusions: Our findings suggest that using self-focused attention reduces IAcc in AN while the opposite pattern was observed in controls. Confronting anorexic patients with bodily features might increase body-related avoidance and therefore decrease interoceptive accuracy. The current study introduces a new perspective concerning the role of interoceptive processes in AN and generates further questions regarding the therapeutic utility of methods targeting self-focus in the

  3. Accuracy and Reliability of the Klales et al. (2012) Morphoscopic Pelvic Sexing Method.

    Science.gov (United States)

    Lesciotto, Kate M; Doershuk, Lily J

    2018-01-01

    Klales et al. (2012) devised an ordinal scoring system for the morphoscopic pelvic traits described by Phenice (1969) and used for sex estimation of skeletal remains. The aim of this study was to test the accuracy and reliability of the Klales method using a large sample from the Hamann-Todd collection (n = 279). Two observers were blinded to sex, ancestry, and age and used the Klales et al. method to estimate the sex of each individual. Sex was correctly estimated for females with over 95% accuracy; however, the male allocation accuracy was approximately 50%. Weighted Cohen's kappa and intraclass correlation coefficient analysis for evaluating intra- and interobserver error showed moderate to substantial agreement for all traits. Although each trait can be reliably scored using the Klales method, low accuracy rates and high sex bias indicate better trait descriptions and visual guides are necessary to more accurately reflect the range of morphological variation. © 2017 American Academy of Forensic Sciences.

  4. NEW OBSERVATIONAL CONSTRAINTS ON THE υ ANDROMEDAE SYSTEM WITH DATA FROM THE HUBBLE SPACE TELESCOPE AND HOBBY-EBERLY TELESCOPE

    International Nuclear Information System (INIS)

    McArthur, Barbara E.; Benedict, G. Fritz.; Martioli, Eder; Barnes, Rory; Korzennik, Sylvain; Nelan, Ed; Butler, R. Paul

    2010-01-01

    We have used high-cadence radial velocity (RV) measurements from the Hobby-Eberly Telescope with existing velocities from the Lick, Elodie, Harlan J. Smith, and Whipple 60'' telescopes combined with astrometric data from the Hubble Space Telescope Fine Guidance Sensors to refine the orbital parameters and determine the orbital inclinations and position angles of the ascending node of components υ And A c and d. With these inclinations and using M * = 1.31M sun as a primary mass, we determine the actual masses of two of the companions: υ And A c is 13.98 +2.3 -5.3 M JUP , and υ And A d is 10.25 +0.7 -3.3 M JUP . These measurements represent the first astrometric determination of mutual inclination between objects in an extrasolar planetary system, which we find to be 29. 0 9 ± 1 0 . The combined RV measurements also reveal a long-period trend indicating a fourth planet in the system. We investigate the dynamic stability of this system and analyze regions of stability, which suggest a probable mass of υ And A b. Finally, our parallaxes confirm that υ And B is a stellar companion of υ And A.

  5. High Accuracy Nonlinear Control and Estimation for Machine Tool Systems

    DEFF Research Database (Denmark)

    Papageorgiou, Dimitrios

    Component mass production has been the backbone of industry since the second industrial revolution, and machine tools are producing parts of widely varying size and design complexity. The ever-increasing level of automation in modern manufacturing processes necessitates the use of more...... sophisticated machine tool systems that are adaptable to different workspace conditions, while at the same time being able to maintain very narrow workpiece tolerances. The main topic of this thesis is to suggest control methods that can maintain required manufacturing tolerances, despite moderate wear and tear....... The purpose is to ensure that full accuracy is maintained between service intervals and to advice when overhaul is needed. The thesis argues that quality of manufactured components is directly related to the positioning accuracy of the machine tool axes, and it shows which low level control architectures...

  6. Prediction of novel pre-microRNAs with high accuracy through boosting and SVM.

    Science.gov (United States)

    Zhang, Yuanwei; Yang, Yifan; Zhang, Huan; Jiang, Xiaohua; Xu, Bo; Xue, Yu; Cao, Yunxia; Zhai, Qian; Zhai, Yong; Xu, Mingqing; Cooke, Howard J; Shi, Qinghua

    2011-05-15

    High-throughput deep-sequencing technology has generated an unprecedented number of expressed short sequence reads, presenting not only an opportunity but also a challenge for prediction of novel microRNAs. To verify the existence of candidate microRNAs, we have to show that these short sequences can be processed from candidate pre-microRNAs. However, it is laborious and time consuming to verify these using existing experimental techniques. Therefore, here, we describe a new method, miRD, which is constructed using two feature selection strategies based on support vector machines (SVMs) and boosting method. It is a high-efficiency tool for novel pre-microRNA prediction with accuracy up to 94.0% among different species. miRD is implemented in PHP/PERL+MySQL+R and can be freely accessed at http://mcg.ustc.edu.cn/rpg/mird/mird.php.

  7. High Accuracy mass Measurement of the very Short-Lived Halo Nuclide $^{11}$Li

    CERN Multimedia

    Le scornet, G

    2002-01-01

    The archetypal halo nuclide $^{11}$Li has now attracted a wealth of experimental and theoretical attention. The most outstanding property of this nuclide, its extended radius that makes it as big as $^{48}$Ca, is highly dependent on the binding energy of the two neutrons forming the halo. New generation experiments using radioactive beams with elastic proton scattering, knock-out and transfer reactions, together with $\\textit{ab initio}$ calculations require the tightening of the constraint on the binding energy. Good metrology also requires confirmation of the sole existing precision result to guard against a possible systematic deviation (or mistake). We propose a high accuracy mass determintation of $^{11}$Li, a particularly challenging task due to its very short half-life of 8.6 ms, but one perfectly suiting the MISTRAL spectrometer, now commissioned at ISOLDE. We request 15 shifts of beam time.

  8. Introducing ADES: A New IAU Astrometry Data Exchange Standard

    Science.gov (United States)

    Chesley, Steven R.; Hockney, George M.; Holman, Matthew J.

    2017-10-01

    For several decades, small body astrometry has been exchanged, distributed and archived in the form of 80-column ASCII records. As a replacement for this obsolescent format, we have worked with a number of members of the community to develop the Astrometric Data Exchange Standard (ADES), which was formally adopted by IAU Commission 20 in August 2015 at the XXIX General Assembly in Honolulu, Hawaii.The purpose of ADES is to ensure that useful and available observational information is submitted, archived, and disseminated as needed. Availability of more complete information will allow orbit computers to process the data more correctly, leading to improved accuracy and reliability of orbital fits. In this way, it will be possible to fully exploit the improving accuracy and increasing number of both optical and radar observations. ADES overcomes several limitations of the previous format by allowing characterization of astrometric and photometric errors, adequate precision in time and angle fields, and flexibility and extensibility.To accommodate a diverse base of users, from automated surveys to hands-on follow-up observers, the ADES protocol allows for two file formats, eXtensible Markup Language (XML) and Pipe-Separated Values (PSV). Each format carries the same information and simple tools allow users to losslessly transform back and forth between XML and PSV.We have further developed and refined ADES since it was first announced in July 2015 [1]. The proposal at that time [2] has undergone several modest revisions to aid validation and avoid overloaded fields. We now have validation schema and file transformation utilities. Suitable example files, test suites, and input/output libraries in a number of modern programming languages are now available. Acknowledgements: Useful feedback during the development of ADES has been received from numerous colleagues in the community of observers and orbit specialists working on asteroids comets and planetary satellites

  9. SPECKLE INTERFEROMETRY AT SOAR IN 2014

    International Nuclear Information System (INIS)

    Tokovinin, Andrei; Mason, Brian D.; Hartkopf, William I.; Mendez, Rene A.; Horch, Elliott P.

    2015-01-01

    The results of speckle interferometric observations at the Southern Astrophysical Research Telescope (SOAR) telescope in 2014 are given. A total of 1641 observations were taken, yielding 1636 measurements of 1218 resolved binary and multiple stars and 577 non-resolutions of 441 targets. We resolved for the first time 56 pairs, including some nearby astrometric or spectroscopic binaries and ten new subsystems in previously known visual binaries. The calibration of the data is checked by linear fits to the positions of 41 wide binaries observed at SOAR over several seasons. The typical calibration accuracy is 0.°1 in angle and 0.3% in pixel scale, while the measurement errors are on the order of 3 mas. The new data are used here to compute 194 binary star orbits, 148 of which are improvements on previous orbital solutions and 46 are first-time orbits

  10. The high resolution optical instruments for the Pleiades HR Earth observation satellites

    Science.gov (United States)

    Gaudin-Delrieu, Catherine; Lamard, Jean-Luc; Cheroutre, Philippe; Bailly, Bruno; Dhuicq, Pierre; Puig, Olivier

    2017-11-01

    Coming after the SPOT satellites series, PLEIADESHR is a CNES optical high resolution satellite dedicated to Earth observation, part of a larger optical and radar multi-sensors system, ORFEO, which is developed in cooperation between France and Italy for dual Civilian and Defense use. The development of the two PLEIADES-HR cameras was entrusted by CNES to Thales Alenia Space. This new generation of instrument represents a breakthrough in comparison with the previous SPOT instruments owing to a significant step in on-ground resolution, which approaches the capabilities of aerial photography. The PLEIADES-HR instrument program benefits from Thales Alenia Space long and successful heritage in Earth observation from space. The proposed solution benefits from an extensive use of existing products, Cannes Space Optics Centre facilities, unique in Europe, dedicated to High Resolution instruments. The optical camera provides wide field panchromatic images supplemented by 4 multispectral channels with narrow spectral bands. The optical concept is based on a four mirrors Korsch telescope. Crucial improvements in detector technology, optical fabrication and electronics make it possible for the PLEIADES-HR instrument to achieve the image quality requirements while respecting the drastic limitations of mass and volume imposed by the satellite agility needs and small launchers compatibility. The two flight telescopes were integrated, aligned and tested. After the integration phase, the alignment, mainly based on interferometric measurements in vacuum chamber, was successfully achieved within high accuracy requirements. The wave front measurements show outstanding performances, confirmed, after the integration of the PFM Detection Unit, by MTF measurements on the Proto-Flight Model Instrument. Delivery of the proto flight model occurred mi-2008. The FM2 Instrument delivery is planned Q2-2009. The first optical satellite launch of the PLEIADES-HR constellation is foreseen

  11. Relationship between the Prediction Accuracy of Tsunami Inundation and Relative Distribution of Tsunami Source and Observation Arrays: A Case Study in Tokyo Bay

    Science.gov (United States)

    Takagawa, T.

    2017-12-01

    A rapid and precise tsunami forecast based on offshore monitoring is getting attention to reduce human losses due to devastating tsunami inundation. We developed a forecast method based on the combination of hierarchical Bayesian inversion with pre-computed database and rapid post-computing of tsunami inundation. The method was applied to Tokyo bay to evaluate the efficiency of observation arrays against three tsunamigenic earthquakes. One is a scenario earthquake at Nankai trough and the other two are historic ones of Genroku in 1703 and Enpo in 1677. In general, rich observation array near the tsunami source has an advantage in both accuracy and rapidness of tsunami forecast. To examine the effect of observation time length we used four types of data with the lengths of 5, 10, 20 and 45 minutes after the earthquake occurrences. Prediction accuracy of tsunami inundation was evaluated by the simulated tsunami inundation areas around Tokyo bay due to target earthquakes. The shortest time length of accurate prediction varied with target earthquakes. Here, accurate prediction means the simulated values fall within the 95% credible intervals of prediction. In Enpo earthquake case, 5-minutes observation is enough for accurate prediction for Tokyo bay, but 10-minutes and 45-minutes are needed in the case of Nankai trough and Genroku, respectively. The difference of the shortest time length for accurate prediction shows the strong relationship with the relative distance from the tsunami source and observation arrays. In the Enpo case, offshore tsunami observation points are densely distributed even in the source region. So, accurate prediction can be rapidly achieved within 5 minutes. This precise prediction is useful for early warnings. Even in the worst case of Genroku, where less observation points are available near the source, accurate prediction can be obtained within 45 minutes. This information can be useful to figure out the outline of the hazard in an early

  12. Accuracy assessment of cadastral maps using high resolution aerial photos

    Directory of Open Access Journals (Sweden)

    Alwan Imzahim

    2018-01-01

    Full Text Available A cadastral map is a map that shows the boundaries and ownership of land parcels. Some cadastral maps show additional details, such as survey district names, unique identifying numbers for parcels, certificate of title numbers, positions of existing structures, section or lot numbers and their respective areas, adjoining and adjacent street names, selected boundary dimensions and references to prior maps. In Iraq / Baghdad Governorate, the main problem is that the cadastral maps are georeferenced to a local geodetic datum known as Clark 1880 while the widely used reference system for navigation purpose (GPS and GNSS and uses Word Geodetic System 1984 (WGS84 as a base reference datum. The objective of this paper is to produce a cadastral map with scale 1:500 (metric scale by using aerial photographs 2009 with high ground spatial resolution 10 cm reference WGS84 system. The accuracy assessment for the cadastral maps updating approach to urban large scale cadastral maps (1:500-1:1000 was ± 0.115 meters; which complies with the American Social for Photogrammetry and Remote Sensing Standards (ASPRS.

  13. Interethnic differences in the accuracy of anthropometric indicators of obesity in screening for high risk of coronary heart disease

    Science.gov (United States)

    Herrera, VM; Casas, JP; Miranda, JJ; Perel, P; Pichardo, R; González, A; Sanchez, JR; Ferreccio, C; Aguilera, X; Silva, E; Oróstegui, M; Gómez, LF; Chirinos, JA; Medina-Lezama, J; Pérez, CM; Suárez, E; Ortiz, AP; Rosero, L; Schapochnik, N; Ortiz, Z; Ferrante, D; Diaz, M; Bautista, LE

    2009-01-01

    Background Cut points for defining obesity have been derived from mortality data among Whites from Europe and the United States and their accuracy to screen for high risk of coronary heart disease (CHD) in other ethnic groups has been questioned. Objective To compare the accuracy and to define ethnic and gender-specific optimal cut points for body mass index (BMI), waist circumference (WC) and waist-to-hip ratio (WHR) when they are used in screening for high risk of CHD in the Latin-American and the US populations. Methods We estimated the accuracy and optimal cut points for BMI, WC and WHR to screen for CHD risk in Latin Americans (n=18 976), non-Hispanic Whites (Whites; n=8956), non-Hispanic Blacks (Blacks; n=5205) and Hispanics (n=5803). High risk of CHD was defined as a 10-year risk ≥20% (Framingham equation). The area under the receiver operator characteristic curve (AUC) and the misclassification-cost term were used to assess accuracy and to identify optimal cut points. Results WHR had the highest AUC in all ethnic groups (from 0.75 to 0.82) and BMI had the lowest (from 0.50 to 0.59). Optimal cut point for BMI was similar across ethnic/gender groups (27 kg/m2). In women, cut points for WC (94 cm) and WHR (0.91) were consistent by ethnicity. In men, cut points for WC and WHR varied significantly with ethnicity: from 91 cm in Latin Americans to 102 cm in Whites, and from 0.94 in Latin Americans to 0.99 in Hispanics, respectively. Conclusion WHR is the most accurate anthropometric indicator to screen for high risk of CHD, whereas BMI is almost uninformative. The same BMI cut point should be used in all men and women. Unique cut points for WC and WHR should be used in all women, but ethnic-specific cut points seem warranted among men. PMID:19238159

  14. Effects of accuracy motivation and anchoring on metacomprehension judgment and accuracy.

    Science.gov (United States)

    Zhao, Qin

    2012-01-01

    The current research investigates how accuracy motivation impacts anchoring and adjustment in metacomprehension judgment and how accuracy motivation and anchoring affect metacomprehension accuracy. Participants were randomly assigned to one of six conditions produced by the between-subjects factorial design involving accuracy motivation (incentive or no) and peer performance anchor (95%, 55%, or no). Two studies showed that accuracy motivation did not impact anchoring bias, but the adjustment-from-anchor process occurred. Accuracy incentive increased anchor-judgment gap for the 95% anchor but not for the 55% anchor, which induced less certainty about the direction of adjustment. The findings offer support to the integrative theory of anchoring. Additionally, the two studies revealed a "power struggle" between accuracy motivation and anchoring in influencing metacomprehension accuracy. Accuracy motivation could improve metacomprehension accuracy in spite of anchoring effect, but if anchoring effect is too strong, it could overpower the motivation effect. The implications of the findings were discussed.

  15. High-accuracy CFD prediction methods for fluid and structure temperature fluctuations at T-junction for thermal fatigue evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Qian, Shaoxiang, E-mail: qian.shaoxiang@jgc.com [EN Technology Center, Process Technology Division, JGC Corporation, 2-3-1 Minato Mirai, Nishi-ku, Yokohama 220-6001 (Japan); Kanamaru, Shinichiro [EN Technology Center, Process Technology Division, JGC Corporation, 2-3-1 Minato Mirai, Nishi-ku, Yokohama 220-6001 (Japan); Kasahara, Naoto [Nuclear Engineering and Management, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)

    2015-07-15

    Highlights: • Numerical methods for accurate prediction of thermal loading were proposed. • Predicted fluid temperature fluctuation (FTF) intensity is close to the experiment. • Predicted structure temperature fluctuation (STF) range is close to the experiment. • Predicted peak frequencies of FTF and STF also agree well with the experiment. • CFD results show the proposed numerical methods are of sufficiently high accuracy. - Abstract: Temperature fluctuations generated by the mixing of hot and cold fluids at a T-junction, which is widely used in nuclear power and process plants, can cause thermal fatigue failure. The conventional methods for evaluating thermal fatigue tend to provide insufficient accuracy, because they were developed based on limited experimental data and a simplified one-dimensional finite element analysis (FEA). CFD/FEA coupling analysis is expected as a useful tool for the more accurate evaluation of thermal fatigue. The present paper aims to verify the accuracy of proposed numerical methods of simulating fluid and structure temperature fluctuations at a T-junction for thermal fatigue evaluation. The dynamic Smagorinsky model (DSM) is used for large eddy simulation (LES) sub-grid scale (SGS) turbulence model, and a hybrid scheme (HS) is adopted for the calculation of convective terms in the governing equations. Also, heat transfer between fluid and structure is calculated directly through thermal conduction by creating a mesh with near wall resolution (NWR) by allocating grid points within the thermal boundary sub-layer. The simulation results show that the distribution of fluid temperature fluctuation intensity and the range of structure temperature fluctuation are remarkably close to the experimental results. Moreover, the peak frequencies of power spectrum density (PSD) of both fluid and structure temperature fluctuations also agree well with the experimental results. Therefore, the numerical methods used in the present paper are

  16. Accuracy of a Wrist-Worn Wearable Device for Monitoring Heart Rates in Hospital Inpatients: A Prospective Observational Study.

    Science.gov (United States)

    Kroll, Ryan R; Boyd, J Gordon; Maslove, David M

    2016-09-20

    As the sensing capabilities of wearable devices improve, there is increasing interest in their application in medical settings. Capabilities such as heart rate monitoring may be useful in hospitalized patients as a means of enhancing routine monitoring or as part of an early warning system to detect clinical deterioration. To evaluate the accuracy of heart rate monitoring by a personal fitness tracker (PFT) among hospital inpatients. We conducted a prospective observational study of 50 stable patients in the intensive care unit who each completed 24 hours of heart rate monitoring using a wrist-worn PFT. Accuracy of heart rate recordings was compared with gold standard measurements derived from continuous electrocardiographic (cECG) monitoring. The accuracy of heart rates measured by pulse oximetry (Spo2.R) was also measured as a positive control. On a per-patient basis, PFT-derived heart rate values were slightly lower than those derived from cECG monitoring (average bias of -1.14 beats per minute [bpm], with limits of agreement of 24 bpm). By comparison, Spo2.R recordings produced more accurate values (average bias of +0.15 bpm, limits of agreement of 13 bpm, P<.001 as compared with PFT). Personal fitness tracker device performance was significantly better in patients in sinus rhythm than in those who were not (average bias -0.99 bpm vs -5.02 bpm, P=.02). Personal fitness tracker-derived heart rates were slightly lower than those derived from cECG monitoring in real-world testing and not as accurate as Spo2.R-derived heart rates. Performance was worse among patients who were not in sinus rhythm. Further clinical evaluation is indicated to see if PFTs can augment early warning systems in hospitals. ClinicalTrials.gov NCT02527408; https://clinicaltrials.gov/ct2/show/NCT02527408 (Archived by WebCite at  http://www.webcitation.org/6kOFez3on).

  17. Assessment of high precision, high accuracy Inductively Coupled Plasma-Optical Emission Spectroscopy to obtain concentration uncertainties less than 0.2% with variable matrix concentrations

    International Nuclear Information System (INIS)

    Rabb, Savelas A.; Olesik, John W.

    2008-01-01

    The ability to obtain high precision, high accuracy measurements in samples with complex matrices using High Performance Inductively Coupled Plasma-Optical Emission Spectroscopy (HP-ICP-OES) was investigated. The Common Analyte Internal Standard (CAIS) procedure was incorporated into the High Performance Inductively Coupled Plasma-Optical Emission Spectroscopy method to correct for matrix-induced changes in emission intensity ratios. Matrix matching and standard addition approaches to minimize matrix-induced errors when using High Performance Inductively Coupled Plasma-Optical Emission Spectroscopy were also assessed. The High Performance Inductively Coupled Plasma-Optical Emission Spectroscopy method was tested with synthetic solutions in a variety of matrices, alloy standard reference materials and geological reference materials

  18. The accuracy of {sup 68}Ga-PSMA PET/CT in primary lymph node staging in high-risk prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Oebek, Can; Doganca, Tuenkut [Acibadem Taksim Hospital, Department of Urology, Istanbul (Turkey); Demirci, Emre [Sisli Etfal Training and Research Hospital, Department of Nuclear Medicine, Istanbul (Turkey); Ocak, Meltem [Istanbul University, Faculty of Pharmacy, Department of Pharmaceutical Technology, Istanbul (Turkey); Kural, Ali Riza [Acibadem University, Department of Urology, Istanbul (Turkey); Yildirim, Asif [Istanbul Medeniyet University, Department of Urology, Istanbul (Turkey); Yuecetas, Ugur [Istanbul Training and Research Hospital, Department of Urology, Istanbul (Turkey); Demirdag, Cetin [Istanbul University, Cerrahpasa School of Medicine, Department of Urology, Istanbul (Turkey); Erdogan, Sarper M. [Istanbul University, Cerrahpasa School of Medicine, Department of Public Health, Istanbul (Turkey); Kabasakal, Levent [Istanbul University, Cerrahpasa School of Medicine, Department of Nuclear Medicine, Istanbul (Turkey); Collaboration: Members of Urooncology Association, Turkey

    2017-10-15

    To assess the diagnostic accuracy of {sup 68}Ga-PSMA PET in predicting lymph node (LN) metastases in primary N staging in high-risk and very high-risk nonmetastatic prostate cancer in comparison with morphological imaging. This was a multicentre trial of the Society of Urologic Oncology in Turkey in conjunction with the Nuclear Medicine Department of Cerrahpasa School of Medicine, Istanbul University. Patients were accrued from eight centres. Patients with high-risk and very high-risk disease scheduled to undergo surgical treatment with extended LN dissection between July 2014 and October 2015 were included. Either MRI or CT was used for morphological imaging. PSMA PET/CT was performed and evaluated at a single centre. Sensitivity, specificity and accuracy were calculated for the detection of lymphatic metastases by PSMA PET/CT and morphological imaging. Kappa values were calculated to evaluate the correlation between the numbers of LN metastases detected by PSMA PET/CT and by histopathology. Data on 51 eligible patients are presented. The sensitivity, specificity and accuracy of PSMA PET in detecting LN metastases in the primary setting were 53%, 86% and 76%, and increased to 67%, 88% and 81% in the subgroup with of patients with ≥15 LN removed. Kappa values for the correlation between imaging and pathology were 0.41 for PSMA PET and 0.18 for morphological imaging. PSMA PET/CT is superior to morphological imaging for the detection of metastatic LNs in patients with primary prostate cancer. Surgical dissection remains the gold standard for precise lymphatic staging. (orig.)

  19. SPECKLE CAMERA OBSERVATIONS FOR THE NASA KEPLER MISSION FOLLOW-UP PROGRAM

    International Nuclear Information System (INIS)

    Howell, Steve B.; Everett, Mark E.; Sherry, William; Horch, Elliott; Ciardi, David R.

    2011-01-01

    We present the first results from a speckle imaging survey of stars classified as candidate exoplanet host stars discovered by the Kepler mission. We use speckle imaging to search for faint companions or closely aligned background stars that could contribute flux to the Kepler light curves of their brighter neighbors. Background stars are expected to contribute significantly to the pool of false positive candidate transiting exoplanets discovered by the Kepler mission, especially in the case that the faint neighbors are eclipsing binary stars. Here, we describe our Kepler follow-up observing program, the speckle imaging camera used, our data reduction, and astrometric and photometric performance. Kepler stars range from R = 8 to 16 and our observations attempt to provide background non-detection limits 5-6 mag fainter and binary separations of ∼0.05-2.0 arcsec. We present data describing the relative brightness, separation, and position angles for secondary sources, as well as relative plate limits for non-detection of faint nearby stars around each of 156 target stars. Faint neighbors were found near 10 of the stars.

  20. Interobserver Variability and Accuracy of High-Definition Endoscopic Diagnosis for Gastric Intestinal Metaplasia among Experienced and Inexperienced Endoscopists

    Science.gov (United States)

    Hyun, Yil Sik; Bae, Joong Ho; Park, Hye Sun; Eun, Chang Soo

    2013-01-01

    Accurate diagnosis of gastric intestinal metaplasia is important; however, conventional endoscopy is known to be an unreliable modality for diagnosing gastric intestinal metaplasia (IM). The aims of the study were to evaluate the interobserver variation in diagnosing IM by high-definition (HD) endoscopy and the diagnostic accuracy of this modality for IM among experienced and inexperienced endoscopists. Selected 50 cases, taken with HD endoscopy, were sent for a diagnostic inquiry of gastric IM through visual inspection to five experienced and five inexperienced endoscopists. The interobserver agreement between endoscopists was evaluated to verify the diagnostic reliability of HD endoscopy in diagnosing IM, and the diagnostic accuracy, sensitivity, and specificity were evaluated for validity of HD endoscopy in diagnosing IM. Interobserver agreement among the experienced endoscopists was "poor" (κ = 0.38) and it was also "poor" (κ = 0.33) among the inexperienced endoscopists. The diagnostic accuracy of the experienced endoscopists was superior to that of the inexperienced endoscopists (P = 0.003). Since diagnosis through visual inspection is unreliable in the diagnosis of IM, all suspicious areas for gastric IM should be considered to be biopsied. Furthermore, endoscopic experience and education are needed to raise the diagnostic accuracy of gastric IM. PMID:23678267

  1. Systematic bias of correlation coefficient may explain negative accuracy of genomic prediction.

    Science.gov (United States)

    Zhou, Yao; Vales, M Isabel; Wang, Aoxue; Zhang, Zhiwu

    2017-09-01

    Accuracy of genomic prediction is commonly calculated as the Pearson correlation coefficient between the predicted and observed phenotypes in the inference population by using cross-validation analysis. More frequently than expected, significant negative accuracies of genomic prediction have been reported in genomic selection studies. These negative values are surprising, given that the minimum value for prediction accuracy should hover around zero when randomly permuted data sets are analyzed. We reviewed the two common approaches for calculating the Pearson correlation and hypothesized that these negative accuracy values reflect potential bias owing to artifacts caused by the mathematical formulas used to calculate prediction accuracy. The first approach, Instant accuracy, calculates correlations for each fold and reports prediction accuracy as the mean of correlations across fold. The other approach, Hold accuracy, predicts all phenotypes in all fold and calculates correlation between the observed and predicted phenotypes at the end of the cross-validation process. Using simulated and real data, we demonstrated that our hypothesis is true. Both approaches are biased downward under certain conditions. The biases become larger when more fold are employed and when the expected accuracy is low. The bias of Instant accuracy can be corrected using a modified formula. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Accuracy of prehospital transport time estimation.

    Science.gov (United States)

    Wallace, David J; Kahn, Jeremy M; Angus, Derek C; Martin-Gill, Christian; Callaway, Clifton W; Rea, Thomas D; Chhatwal, Jagpreet; Kurland, Kristen; Seymour, Christopher W

    2014-01-01

    Estimates of prehospital transport times are an important part of emergency care system research and planning; however, the accuracy of these estimates is unknown. The authors examined the accuracy of three estimation methods against observed transport times in a large cohort of prehospital patient transports. This was a validation study using prehospital records in King County, Washington, and southwestern Pennsylvania from 2002 to 2006 and 2005 to 2011, respectively. Transport time estimates were generated using three methods: linear arc distance, Google Maps, and ArcGIS Network Analyst. Estimation error, defined as the absolute difference between observed and estimated transport time, was assessed, as well as the proportion of estimated times that were within specified error thresholds. Based on the primary results, a regression estimate was used that incorporated population density, time of day, and season to assess improved accuracy. Finally, hospital catchment areas were compared using each method with a fixed drive time. The authors analyzed 29,935 prehospital transports to 44 hospitals. The mean (± standard deviation [±SD]) absolute error was 4.8 (±7.3) minutes using linear arc, 3.5 (±5.4) minutes using Google Maps, and 4.4 (±5.7) minutes using ArcGIS. All pairwise comparisons were statistically significant (p Google Maps, and 11.6 [±10.9] minutes for ArcGIS). Estimates were within 5 minutes of observed transport time for 79% of linear arc estimates, 86.6% of Google Maps estimates, and 81.3% of ArcGIS estimates. The regression-based approach did not substantially improve estimation. There were large differences in hospital catchment areas estimated by each method. Route-based transport time estimates demonstrate moderate accuracy. These methods can be valuable for informing a host of decisions related to the system organization and patient access to emergency medical care; however, they should be employed with sensitivity to their limitations.

  3. Accuracy of abdominal auscultation for bowel obstruction.

    Science.gov (United States)

    Breum, Birger Michael; Rud, Bo; Kirkegaard, Thomas; Nordentoft, Tyge

    2015-09-14

    To investigate the accuracy and inter-observer variation of bowel sound assessment in patients with clinically suspected bowel obstruction. Bowel sounds were recorded in patients with suspected bowel obstruction using a Littmann(®) Electronic Stethoscope. The recordings were processed to yield 25-s sound sequences in random order on PCs. Observers, recruited from doctors within the department, classified the sound sequences as either normal or pathological. The reference tests for bowel obstruction were intraoperative and endoscopic findings and clinical follow up. Sensitivity and specificity were calculated for each observer and compared between junior and senior doctors. Interobserver variation was measured using the Kappa statistic. Bowel sound sequences from 98 patients were assessed by 53 (33 junior and 20 senior) doctors. Laparotomy was performed in 47 patients, 35 of whom had bowel obstruction. Two patients underwent colorectal stenting due to large bowel obstruction. The median sensitivity and specificity was 0.42 (range: 0.19-0.64) and 0.78 (range: 0.35-0.98), respectively. There was no significant difference in accuracy between junior and senior doctors. The median frequency with which doctors classified bowel sounds as abnormal did not differ significantly between patients with and without bowel obstruction (26% vs 23%, P = 0.08). The 53 doctors made up 1378 unique pairs and the median Kappa value was 0.29 (range: -0.15-0.66). Accuracy and inter-observer agreement was generally low. Clinical decisions in patients with possible bowel obstruction should not be based on auscultatory assessment of bowel sounds.

  4. Improving calibration accuracy in gel dosimetry

    International Nuclear Information System (INIS)

    Oldham, M.; McJury, M.; Webb, S.; Baustert, I.B.; Leach, M.O.

    1998-01-01

    A new method of calibrating gel dosimeters (applicable to both Fricke and polyacrylamide gels) is presented which has intrinsically higher accuracy than current methods, and requires less gel. Two test-tubes of gel (inner diameter 2.5 cm, length 20 cm) are irradiated separately with a 10x10cm 2 field end-on in a water bath, such that the characteristic depth-dose curve is recorded in the gel. The calibration is then determined by fitting the depth-dose measured in water, against the measured change in relaxivity with depth in the gel. Increased accuracy is achieved in this simple depth-dose geometry by averaging the relaxivity at each depth. A large number of calibration data points, each with relatively high accuracy, are obtained. Calibration data over the full range of dose (1.6-10 Gy) is obtained by irradiating one test-tube to 10 Gy at dose maximum (D max ), and the other to 4.5 Gy at D max . The new calibration method is compared with a 'standard method' where five identical test-tubes of gel were irradiated to different known doses between 2 and 10 Gy. The percentage uncertainties in the slope and intercept of the calibration fit are found to be lower with the new method by a factor of about 4 and 10 respectively, when compared with the standard method and with published values. The gel was found to respond linearly within the error bars up to doses of 7 Gy, with a slope of 0.233±0.001 s -1 Gy -1 and an intercept of 1.106±0.005 Gy. For higher doses, nonlinear behaviour was observed. (author)

  5. A Tool for Optimizing Observation Planning for Faint Moving Objects

    Science.gov (United States)

    Arredondo, Anicia; Bosh, Amanda S.; Levine, Stephen

    2016-10-01

    Observations of small solar system bodies such as trans-Neptunian objects and Centaurs are vital for understanding the basic properties of these small members of our solar system. Because these objects are often very faint, large telescopes and long exposures may be necessary, which can result in crowded fields in which the target of interest may be blended with a field star. For accurate photometry and astrometry, observations must be planned to occur when the target is free of background stars; this restriction results in limited observing windows. We have created a tool that can be used to plan observations of faint moving objects. Features of the tool include estimates of best times to observe (when the object is not too near another object), a finder chart output, a list of possible astrometric and photometric reference stars, and an exposure time calculator. This work makes use of the USNOFS Image and Catalogue Archive operated by the United States Naval Observatory, Flagstaff Station (S.E. Levine and D.G. Monet 2000), the JPL Horizons online ephemeris service (Giorgini et al. 1996), the Minor Planet Center's MPChecker (http://cgi.minorplanetcenter.net/cgi-bin/checkmp.cgi), and source extraction software SExtractor (Bertin & Arnouts 1996). Support for this work was provided by NASA SSO grant NNX15AJ82G.

  6. Diagnostic accuracy of Tc-99m MIBI scintimammography in breast cancer

    International Nuclear Information System (INIS)

    Park, Jung Mi; Choi, Joon Young; Lee, Kyung Han; Kim, Sang Eun; Kim, Byung Tae; Nam, Suk Jin; Yang, Jung Hyun

    1998-01-01

    For the characterization of breast mass, the results of Tc-99m MIBI scintimmamography were much varied between studies. This may result from various factors including tumor size, experience of observer and expression of MDR gene, So, we evaluated the influence of tumor size, knowledge of clinical information, experience of observer and expression of Pgp53 gene on the accuracy of MIBI scintimmamography for the characterization of breast mass. MIBI scintimmamography was prospectively performed in 44 patients with breast masses before surgical resection. The anterior and both lateral prone chest images were acquired at 5 min and 3 hour after injection of 740 MBq of Tc-99m MIBI. Two independent observers reviewed the images for characterization of breast mass without any clinical information. Then the images were reviewed with knowledge of clinical information including tumor size and location. If lesions proved to be malignant, presence of Pgp53 was evaluated by immunohistochemical staining. The comparisons of intraobserver/interobserver diagnostic accuracy and variance were performed by chi-square test and kappa test, respectively. The 54.4% of all lesions (24/44) were malignant. The sensitive, specificity and accuracy of scintimmamography were 73.3%, 82.8%, 79.5% and 73.3%, 84.5%, 80.7% with/without clinical information in observer A, and 76.7%, 86.2%, 83% and 70%, 89.7%, 83% with/without clinical information in observer B, respectively. There were no significant differences in sensitivity, specificity and accuracy between two observers or in same observer with/without clinical information. The agreement for the characterization of breast mass between the two observers was significantly excellent (κ=0.876/ κ=0.897 with/without clinical information, respectively). Intraobserver variance according to the knowledge of clinical information was also small ( κ=0.795 in observer A; κ=0.900 in observer B). Pgp53 was positive in 8 lesions. The sensitivities of

  7. Astrometric observations of comets and asteroids and subsequent orbital investigations. Semiannual progress report No. 30, 1 May-31 October 1988

    International Nuclear Information System (INIS)

    Mccroskey, R.E.; Marsden, B.G.

    1988-11-01

    The 155-cm reflector was used for observations of comets and minor planets on 28 nights during April-October. Twenty-two of the observations refer to comets, 62 to numbered minor planets (numbered, that is, by the end of the semester: only nine of them refer to minor planets already numbered at the time of the last report), and the remainer to unnumbered minor planets. Observations were made of four new comets discovered during the semester and a fifth discovered in January. Observations of Wilson (19861), P/Tempel 2 and two other returning short-period comets are also continuing. Among the odd numbered minor planets observed were the earth-approaching objects (1685) Toro and (1980) Tezcatlipoca. The Earth approacher 1980 PA was numbered (3908)

  8. A three axis turntable's online initial state measurement method based on the high-accuracy laser gyro SINS

    Science.gov (United States)

    Gao, Chunfeng; Wei, Guo; Wang, Qi; Xiong, Zhenyu; Wang, Qun; Long, Xingwu

    2016-10-01

    As an indispensable equipment in inertial technology tests, the three-axis turntable is widely used in the calibration of various types inertial navigation systems (INS). In order to ensure the calibration accuracy of INS, we need to accurately measure the initial state of the turntable. However, the traditional measuring method needs a lot of exterior equipment (such as level instrument, north seeker, autocollimator, etc.), and the test processing is complex, low efficiency. Therefore, it is relatively difficult for the inertial measurement equipment manufacturers to realize the self-inspection of the turntable. Owing to the high precision attitude information provided by the laser gyro strapdown inertial navigation system (SINS) after fine alignment, we can use it as the attitude reference of initial state measurement of three-axis turntable. For the principle that the fixed rotation vector increment is not affected by measuring point, we use the laser gyro INS and the encoder of the turntable to provide the attitudes of turntable mounting plat. Through this way, the high accuracy measurement of perpendicularity error and initial attitude of the three-axis turntable has been achieved.

  9. High Accuracy Human Activity Recognition Based on Sparse Locality Preserving Projections.

    Science.gov (United States)

    Zhu, Xiangbin; Qiu, Huiling

    2016-01-01

    Human activity recognition(HAR) from the temporal streams of sensory data has been applied to many fields, such as healthcare services, intelligent environments and cyber security. However, the classification accuracy of most existed methods is not enough in some applications, especially for healthcare services. In order to improving accuracy, it is necessary to develop a novel method which will take full account of the intrinsic sequential characteristics for time-series sensory data. Moreover, each human activity may has correlated feature relationship at different levels. Therefore, in this paper, we propose a three-stage continuous hidden Markov model (TSCHMM) approach to recognize human activities. The proposed method contains coarse, fine and accurate classification. The feature reduction is an important step in classification processing. In this paper, sparse locality preserving projections (SpLPP) is exploited to determine the optimal feature subsets for accurate classification of the stationary-activity data. It can extract more discriminative activities features from the sensor data compared with locality preserving projections. Furthermore, all of the gyro-based features are used for accurate classification of the moving data. Compared with other methods, our method uses significantly less number of features, and the over-all accuracy has been obviously improved.

  10. High Accuracy Human Activity Recognition Based on Sparse Locality Preserving Projections.

    Directory of Open Access Journals (Sweden)

    Xiangbin Zhu

    Full Text Available Human activity recognition(HAR from the temporal streams of sensory data has been applied to many fields, such as healthcare services, intelligent environments and cyber security. However, the classification accuracy of most existed methods is not enough in some applications, especially for healthcare services. In order to improving accuracy, it is necessary to develop a novel method which will take full account of the intrinsic sequential characteristics for time-series sensory data. Moreover, each human activity may has correlated feature relationship at different levels. Therefore, in this paper, we propose a three-stage continuous hidden Markov model (TSCHMM approach to recognize human activities. The proposed method contains coarse, fine and accurate classification. The feature reduction is an important step in classification processing. In this paper, sparse locality preserving projections (SpLPP is exploited to determine the optimal feature subsets for accurate classification of the stationary-activity data. It can extract more discriminative activities features from the sensor data compared with locality preserving projections. Furthermore, all of the gyro-based features are used for accurate classification of the moving data. Compared with other methods, our method uses significantly less number of features, and the over-all accuracy has been obviously improved.

  11. High-accuracy contouring using projection moiré

    Science.gov (United States)

    Sciammarella, Cesar A.; Lamberti, Luciano; Sciammarella, Federico M.

    2005-09-01

    Shadow and projection moiré are the oldest forms of moiré to be used in actual technical applications. In spite of this fact and the extensive number of papers that have been published on this topic, the use of shadow moiré as an accurate tool that can compete with alternative devices poses very many problems that go to the very essence of the mathematical models used to obtain contour information from fringe pattern data. In this paper some recent developments on the projection moiré method are presented. Comparisons between the results obtained with the projection method and the results obtained by mechanical devices that operate with contact probes are presented. These results show that the use of projection moiré makes it possible to achieve the same accuracy that current mechanical touch probe devices can provide.

  12. High accuracy amplitude and phase measurements based on a double heterodyne architecture

    International Nuclear Information System (INIS)

    Zhao Danyang; Wang Guangwei; Pan Weimin

    2015-01-01

    In the digital low level RF (LLRF) system of a circular (particle) accelerator, the RF field signal is usually down converted to a fixed intermediate frequency (IF). The ratio of IF and sampling frequency determines the processing required, and differs in various LLRF systems. It is generally desirable to design a universally compatible architecture for different IFs with no change to the sampling frequency and algorithm. A new RF detection method based on a double heterodyne architecture for wide IF range has been developed, which achieves the high accuracy requirement of modern LLRF. In this paper, the relation of IF and phase error is systematically analyzed for the first time and verified by experiments. The effects of temperature drift for 16 h IF detection are inhibited by the amplitude and phase calibrations. (authors)

  13. Accuracy of thick-walled hollows during piercing on three-high mill

    International Nuclear Information System (INIS)

    Potapov, I.N.; Romantsev, B.A.; Shamanaev, V.I.; Popov, V.A.; Kharitonov, E.A.

    1975-01-01

    The results of investigations are presented concerning the accuracy of geometrical dimensions of thick-walled sleeves produced by piercing on a 100-ton trio screw rolling mill MISiS with three schemes of fixing and centering the rod. The use of a spherical thrust journal for the rod and of a long centering bushing makes it possible to diminish the non-uniformity of the wall thickness of the sleeves by 30-50%. It is established that thick-walled sleeves with accurate geometrical dimensions (nonuniformity of the wall thickness being less than 10%) can be produced if the system sleeve - mandrel - rod is highly rigid and the rod has a two- or three-fold stability margin over the length equal to that of the sleeve being pierced. The process of piercing is expedient to be carried out with increased angles of feed (14-16 deg). Blanks have been made from steel 12Kh1MF

  14. An automated method for the evaluation of the pointing accuracy of Sun-tracking devices

    Science.gov (United States)

    Baumgartner, Dietmar J.; Pötzi, Werner; Freislich, Heinrich; Strutzmann, Heinz; Veronig, Astrid M.; Rieder, Harald E.

    2017-03-01

    The accuracy of solar radiation measurements, for direct (DIR) and diffuse (DIF) radiation, depends significantly on the precision of the operational Sun-tracking device. Thus, rigid targets for instrument performance and operation have been specified for international monitoring networks, e.g., the Baseline Surface Radiation Network (BSRN) operating under the auspices of the World Climate Research Program (WCRP). Sun-tracking devices that fulfill these accuracy requirements are available from various instrument manufacturers; however, none of the commercially available systems comprise an automatic accuracy control system allowing platform operators to independently validate the pointing accuracy of Sun-tracking sensors during operation. Here we present KSO-STREAMS (KSO-SunTRackEr Accuracy Monitoring System), a fully automated, system-independent, and cost-effective system for evaluating the pointing accuracy of Sun-tracking devices. We detail the monitoring system setup, its design and specifications, and the results from its application to the Sun-tracking system operated at the Kanzelhöhe Observatory (KSO) Austrian radiation monitoring network (ARAD) site. The results from an evaluation campaign from March to June 2015 show that the tracking accuracy of the device operated at KSO lies within BSRN specifications (i.e., 0.1° tracking accuracy) for the vast majority of observations (99.8 %). The evaluation of manufacturer-specified active-tracking accuracies (0.02°), during periods with direct solar radiation exceeding 300 W m-2, shows that these are satisfied in 72.9 % of observations. Tracking accuracies are highest during clear-sky conditions and on days where prevailing clear-sky conditions are interrupted by frontal movement; in these cases, we obtain the complete fulfillment of BSRN requirements and 76.4 % of observations within manufacturer-specified active-tracking accuracies. Limitations to tracking surveillance arise during overcast conditions and

  15. Model Accuracy Comparison for High Resolution Insar Coherence Statistics Over Urban Areas

    Science.gov (United States)

    Zhang, Yue; Fu, Kun; Sun, Xian; Xu, Guangluan; Wang, Hongqi

    2016-06-01

    The interferometric coherence map derived from the cross-correlation of two complex registered synthetic aperture radar (SAR) images is the reflection of imaged targets. In many applications, it can act as an independent information source, or give additional information complementary to the intensity image. Specially, the statistical properties of the coherence are of great importance in land cover classification, segmentation and change detection. However, compared to the amount of work on the statistical characters of SAR intensity, there are quite fewer researches on interferometric SAR (InSAR) coherence statistics. And to our knowledge, all of the existing work that focuses on InSAR coherence statistics, models the coherence with Gaussian distribution with no discrimination on data resolutions or scene types. But the properties of coherence may be different for different data resolutions and scene types. In this paper, we investigate on the coherence statistics for high resolution data over urban areas, by making a comparison of the accuracy of several typical statistical models. Four typical land classes including buildings, trees, shadow and roads are selected as the representatives of urban areas. Firstly, several regions are selected from the coherence map manually and labelled with their corresponding classes respectively. Then we try to model the statistics of the pixel coherence for each type of region, with different models including Gaussian, Rayleigh, Weibull, Beta and Nakagami. Finally, we evaluate the model accuracy for each type of region. The experiments on TanDEM-X data show that the Beta model has a better performance than other distributions.

  16. MODEL ACCURACY COMPARISON FOR HIGH RESOLUTION INSAR COHERENCE STATISTICS OVER URBAN AREAS

    Directory of Open Access Journals (Sweden)

    Y. Zhang

    2016-06-01

    Full Text Available The interferometric coherence map derived from the cross-correlation of two complex registered synthetic aperture radar (SAR images is the reflection of imaged targets. In many applications, it can act as an independent information source, or give additional information complementary to the intensity image. Specially, the statistical properties of the coherence are of great importance in land cover classification, segmentation and change detection. However, compared to the amount of work on the statistical characters of SAR intensity, there are quite fewer researches on interferometric SAR (InSAR coherence statistics. And to our knowledge, all of the existing work that focuses on InSAR coherence statistics, models the coherence with Gaussian distribution with no discrimination on data resolutions or scene types. But the properties of coherence may be different for different data resolutions and scene types. In this paper, we investigate on the coherence statistics for high resolution data over urban areas, by making a comparison of the accuracy of several typical statistical models. Four typical land classes including buildings, trees, shadow and roads are selected as the representatives of urban areas. Firstly, several regions are selected from the coherence map manually and labelled with their corresponding classes respectively. Then we try to model the statistics of the pixel coherence for each type of region, with different models including Gaussian, Rayleigh, Weibull, Beta and Nakagami. Finally, we evaluate the model accuracy for each type of region. The experiments on TanDEM-X data show that the Beta model has a better performance than other distributions.

  17. High construal level can help negotiators to reach integrative agreements: The role of information exchange and judgement accuracy.

    Science.gov (United States)

    Wening, Stefanie; Keith, Nina; Abele, Andrea E

    2016-06-01

    In negotiations, a focus on interests (why negotiators want something) is key to integrative agreements. Yet, many negotiators spontaneously focus on positions (what they want), with suboptimal outcomes. Our research applies construal-level theory to negotiations and proposes that a high construal level instigates a focus on interests during negotiations which, in turn, positively affects outcomes. In particular, we tested the notion that the effect of construal level on outcomes was mediated by information exchange and judgement accuracy. Finally, we expected the mere mode of presentation of task material to affect construal levels and manipulated construal levels using concrete versus abstract negotiation tasks. In two experiments, participants negotiated in dyads in either a high- or low-construal-level condition. In Study 1, high-construal-level dyads outperformed dyads in the low-construal-level condition; this main effect was mediated by information exchange. Study 2 replicated both the main and mediation effects using judgement accuracy as mediator and additionally yielded a positive effect of a high construal level on a second, more complex negotiation task. These results not only provide empirical evidence for the theoretically proposed link between construal levels and negotiation outcomes but also shed light on the processes underlying this effect. © 2015 The British Psychological Society.

  18. Gaia DR2 documentation Chapter 3: Astrometry

    Science.gov (United States)

    Hobbs, D.; Lindegren, L.; Bastian, U.; Klioner, S.; Butkevich, A.; Stephenson, C.; Hernandez, J.; Lammers, U.; Bombrun, A.; Mignard, F.; Altmann, M.; Davidson, M.; de Bruijne, J. H. J.; Fernández-Hernández, J.; Siddiqui, H.; Utrilla Molina, E.

    2018-04-01

    This chapter of the Gaia DR2 documentation describes the models and processing steps used for the astrometric core solution, namely, the Astrometric Global Iterative Solution (AGIS). The inputs to this solution rely heavily on the basic observables (or astrometric elementaries) which have been pre-processed and discussed in Chapter 2, the results of which were published in Fabricius et al. (2016). The models consist of reference systems and time scales; assumed linear stellar motion and relativistic light deflection; in addition to fundamental constants and the transformation of coordinate systems. Higher level inputs such as: planetary and solar system ephemeris; Gaia tracking and orbit information; initial quasar catalogues and BAM data are all needed for the processing described here. The astrometric calibration models are outlined followed by the details processing steps which give AGIS its name. We also present a basic quality assessment and validation of the scientific results (for details, see Lindegren et al. 2018).

  19. What do we mean by accuracy in geomagnetic measurements?

    Science.gov (United States)

    Green, A.W.

    1990-01-01

    High accuracy is what distinguishes measurements made at the world's magnetic observatories from other types of geomagnetic measurements. High accuracy in determining the absolute values of the components of the Earth's magnetic field is essential to studying geomagnetic secular variation and processes at the core mantle boundary, as well as some magnetospheric processes. In some applications of geomagnetic data, precision (or resolution) of measurements may also be important. In addition to accuracy and resolution in the amplitude domain, it is necessary to consider these same quantities in the frequency and space domains. New developments in geomagnetic instruments and communications make real-time, high accuracy, global geomagnetic observatory data sets a real possibility. There is a growing realization in the scientific community of the unique relevance of geomagnetic observatory data to the principal contemporary problems in solid Earth and space physics. Together, these factors provide the promise of a 'renaissance' of the world's geomagnetic observatory system. ?? 1990.

  20. Checking the predictive accuracy of basic symptoms against ultra high-risk criteria and testing of a multivariable prediction model: Evidence from a prospective three-year observational study of persons at clinical high-risk for psychosis.

    Science.gov (United States)

    Hengartner, M P; Heekeren, K; Dvorsky, D; Walitza, S; Rössler, W; Theodoridou, A

    2017-09-01

    The aim of this study was to critically examine the prognostic validity of various clinical high-risk (CHR) criteria alone and in combination with additional clinical characteristics. A total of 188 CHR positive persons from the region of Zurich, Switzerland (mean age 20.5 years; 60.2% male), meeting ultra high-risk (UHR) and/or basic symptoms (BS) criteria, were followed over three years. The test battery included the Structured Interview for Prodromal Syndromes (SIPS), verbal IQ and many other screening tools. Conversion to psychosis was defined according to ICD-10 criteria for schizophrenia (F20) or brief psychotic disorder (F23). Altogether n=24 persons developed manifest psychosis within three years and according to Kaplan-Meier survival analysis, the projected conversion rate was 17.5%. The predictive accuracy of UHR was statistically significant but poor (area under the curve [AUC]=0.65, Pthinking of binary at-risk criteria is necessary in order to improve the prognosis of psychotic disorders. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. VERA observations of the Galactic star-forming regions ON1 and ON2N

    Science.gov (United States)

    Nagayama, Takumi

    2013-02-01

    We carried out astrometric observations with VERA of H2O masers in ON1 and ON2N. The measured distances to ON1 and ON2N are 2.47 +/- 0.11 and 3.83 +/- 0.13 kpc, respectively. We found that ON1 and ON2N are located near the tangent point and the Solar circle, respectively. We derive an angular velocity of the Galactic rotation at the Sun's position (i.e. the ratio of the Galactic constants) of 28 +/- 2 km s-1 kpc-1 using the measured distances and three-dimensional velocity components of the two sources. This value is consistent with recent estimates obtained using Very Long Baseline Interferometry but different from the IAU-recommended value of 25.9 km s-1 kpc-1.

  2. High diagnostic accuracy of the Sysmex XT-2000iV delta total nucleated cells on effusions for feline infectious peritonitis.

    Science.gov (United States)

    Giordano, Alessia; Stranieri, Angelica; Rossi, Gabriele; Paltrinieri, Saverio

    2015-06-01

    The ΔWBC (the ratio between DIFF and BASO counts of the Sysmex XT-2000iV), hereafter defined as ΔTNC (total nucleated cells), is high in effusions due to feline infectious peritonitis (FIP), as cells are entrapped in fibrin clots formed in the BASO reagent. Similar clots form in the Rivalta's test, a method with high diagnostic accuracy for FIP. The objective of this study was to determine the diagnostic accuracy for FIP and the optimal cutoff of ΔTNC. After a retrospective search of our database, DIFF and BASO counts, and the ΔTNC from cats with and without FIP were compared to each other. Sensitivity, specificity, and positive and negative likelihood ratios (LR+, LR-) were calculated. A ROC curve was designed to determine the cutoff for best sensitivity and specificity. Effusions from 20 FIP and 31 non-FIP cats were analyzed. The ΔTNC was higher (P  2.5 had 100% specificity. The ΔTNC has a high diagnostic accuracy for FIP-related effusions by providing an estimate of precipitable proteins, as the Rivalta's test, in addition to the cell count. As fibrin clots result in false lower BASO counts, the ΔTNC is preferable to the WBC count generated by the BASO channel alone in suspected FIP effusions. © 2015 American Society for Veterinary Clinical Pathology.

  3. "Dilute-and-inject" multi-target screening assay for highly polar doping agents using hydrophilic interaction liquid chromatography high resolution/high accuracy mass spectrometry for sports drug testing.

    Science.gov (United States)

    Görgens, Christian; Guddat, Sven; Orlovius, Anne-Katrin; Sigmund, Gerd; Thomas, Andreas; Thevis, Mario; Schänzer, Wilhelm

    2015-07-01

    In the field of LC-MS, reversed phase liquid chromatography is the predominant method of choice for the separation of prohibited substances from various classes in sports drug testing. However, highly polar and charged compounds still represent a challenging task in liquid chromatography due to their difficult chromatographic behavior using reversed phase materials. A very promising approach for the separation of hydrophilic compounds is hydrophilic interaction liquid chromatography (HILIC). Despite its great potential and versatile advantages for the separation of highly polar compounds, HILIC is up to now not very common in doping analysis, although most manufacturers offer a variety of HILIC columns in their portfolio. In this study, a novel multi-target approach based on HILIC high resolution/high accuracy mass spectrometry is presented to screen for various polar stimulants, stimulant sulfo-conjugates, glycerol, AICAR, ethyl glucuronide, morphine-3-glucuronide, and myo-inositol trispyrophosphate after direct injection of diluted urine specimens. The usage of an effective online sample cleanup and a zwitterionic HILIC analytical column in combination with a new generation Hybrid Quadrupol-Orbitrap® mass spectrometer enabled the detection of highly polar analytes without any time-consuming hydrolysis or further purification steps, far below the required detection limits. The methodology was fully validated for qualitative and quantitative (AICAR, glycerol) purposes considering the parameters specificity; robustness (rRT  0.99); intra- and inter-day precision at low, medium, and high concentration levels (CV < 20%); limit of detection (stimulants and stimulant sulfo-conjugates < 10 ng/mL; norfenefrine; octopamine < 30 ng/mL; AICAR < 10 ng/mL; glycerol 100 μg/mL; ETG < 100 ng/mL); accuracy (AICAR 103.8-105.5%, glycerol 85.1-98.3% at three concentration levels) and ion suppression/enhancement effects.

  4. Target Price Accuracy

    Directory of Open Access Journals (Sweden)

    Alexander G. Kerl

    2011-04-01

    Full Text Available This study analyzes the accuracy of forecasted target prices within analysts’ reports. We compute a measure for target price forecast accuracy that evaluates the ability of analysts to exactly forecast the ex-ante (unknown 12-month stock price. Furthermore, we determine factors that explain this accuracy. Target price accuracy is negatively related to analyst-specific optimism and stock-specific risk (measured by volatility and price-to-book ratio. However, target price accuracy is positively related to the level of detail of each report, company size and the reputation of the investment bank. The potential conflicts of interests between an analyst and a covered company do not bias forecast accuracy.

  5. Ex-post evaluations of demand forecast accuracy

    DEFF Research Database (Denmark)

    Nicolaisen, Morten Skou; Driscoll, Patrick Arthur

    2014-01-01

    Travel demand forecasts play a crucial role in the preparation of decision support to policy makers in the field of transport planning. The results feed directly into impact appraisals such as cost benefit analyses and environmental impact assessments, which are mandatory for large public works...... projects in many countries. Over the last couple of decades there has been an increasing attention to the lack of demand forecast accuracy, but since data availability for comprehensive ex- post appraisals is problematic, such studies are still relatively rare. The present paper presents a review...... of the largest ex-post studies of demand forecast accuracy for transport infrastructure projects. The focus is twofold; to provide an overview of observed levels of demand forecast inaccuracy and to explore the primary explanations offered for the observed inaccuracy. Inaccuracy in the form of both bias...

  6. Accuracy of Genomic Selection in a Rice Synthetic Population Developed for Recurrent Selection Breeding.

    Science.gov (United States)

    Grenier, Cécile; Cao, Tuong-Vi; Ospina, Yolima; Quintero, Constanza; Châtel, Marc Henri; Tohme, Joe; Courtois, Brigitte; Ahmadi, Nourollah

    2015-01-01

    Genomic selection (GS) is a promising strategy for enhancing genetic gain. We investigated the accuracy of genomic estimated breeding values (GEBV) in four inter-related synthetic populations that underwent several cycles of recurrent selection in an upland rice-breeding program. A total of 343 S2:4 lines extracted from those populations were phenotyped for flowering time, plant height, grain yield and panicle weight, and genotyped with an average density of one marker per 44.8 kb. The relative effect of the linkage disequilibrium (LD) and minor allele frequency (MAF) thresholds for selecting markers, the relative size of the training population (TP) and of the validation population (VP), the selected trait and the genomic prediction models (frequentist and Bayesian) on the accuracy of GEBVs was investigated in 540 cross validation experiments with 100 replicates. The effect of kinship between the training and validation populations was tested in an additional set of 840 cross validation experiments with a single genomic prediction model. LD was high (average r2 = 0.59 at 25 kb) and decreased slowly, distribution of allele frequencies at individual loci was markedly skewed toward unbalanced frequencies (MAF average value 15.2% and median 9.6%), and differentiation between the four synthetic populations was low (FST ≤0.06). The accuracy of GEBV across all cross validation experiments ranged from 0.12 to 0.54 with an average of 0.30. Significant differences in accuracy were observed among the different levels of each factor investigated. Phenotypic traits had the biggest effect, and the size of the incidence matrix had the smallest. Significant first degree interaction was observed for GEBV accuracy between traits and all the other factors studied, and between prediction models and LD, MAF and composition of the TP. The potential of GS to accelerate genetic gain and breeding options to increase the accuracy of predictions are discussed.

  7. Does experience in hysteroscopy improve accuracy and inter-observer agreement in the management of abnormal uterine bleeding?

    Science.gov (United States)

    Bourdel, Nicolas; Modaffari, Paola; Tognazza, Enrica; Pertile, Riccardo; Chauvet, Pauline; Botchorishivili, Revaz; Savary, Dennis; Pouly, Jean Luc; Rabischong, Benoit; Canis, Michel

    2016-12-01

    Hysteroscopic reliability may be influenced by the experience of the operator and by a lack of morphological diagnostic criteria for endometrial malignant pathologies. The aim of this study was to evaluate the diagnostic accuracy and the inter-observer agreement (IOA) in the management of abnormal uterine bleeding (AUB) among different experienced gynecologists. Each gynecologist, without any other clinical information, was asked to evaluate the anonymous video recordings of 51 consecutive patients who underwent hysteroscopy and endometrial resection for AUB. Experts (>500 hysteroscopies), seniors (20-499 procedures) and junior (≤19 procedures) gynecologists were asked to judge endometrial macroscopic appearance (benign, suspicious or frankly malignant). They also had to propose the histological diagnosis (atrophic or proliferative endometrium; simple, glandulocystic or atypical endometrial hyperplasia and endometrial carcinoma). Observers were free to indicate whether the quality of recordings were not good enough for adequate assessment. IOA (k coefficient), sensitivity, specificity, predictive value and the likelihood ratio were calculated. Five expert, five senior and six junior gynecologists were involved in the study. Considering endometrial cancer and endometrial atypical hyperplasia, sensitivity and specificity were respectively 55.5 % and 84.5 % for juniors, 66.6 % and 81.2 % for seniors and 86.6 % and 87.3 % for experts. Concerning endometrial macroscopic appearance, IOA was poor for juniors (k = 0.10) and fair for seniors and experts (k = 0.23 and 0.22, respectively). IOA was poor for juniors and experts (k = 0.18 and 0.20, respectively) and fair for seniors (k = 0.30) in predicting the histological diagnosis. Sensitivity improves with the observer's experience, but inter-observer agreement and reproducibility of hysteroscopy for endometrial malignancies are not satisfying no matter the level of expertise. Therefore, an accurate and

  8. Accuracy of a radiofrequency identification (RFID) badge system to monitor hand hygiene behavior during routine clinical activities.

    Science.gov (United States)

    Pineles, Lisa L; Morgan, Daniel J; Limper, Heather M; Weber, Stephen G; Thom, Kerri A; Perencevich, Eli N; Harris, Anthony D; Landon, Emily

    2014-02-01

    Hand hygiene (HH) is a critical part of infection prevention in health care settings. Hospitals around the world continuously struggle to improve health care personnel (HCP) HH compliance. The current gold standard for monitoring compliance is direct observation; however, this method is time-consuming and costly. One emerging area of interest involves automated systems for monitoring HH behavior such as radiofrequency identification (RFID) tracking systems. To assess the accuracy of a commercially available RFID system in detecting HCP HH behavior, we compared direct observation with data collected by the RFID system in a simulated validation setting and to a real-life clinical setting over 2 hospitals. A total of 1,554 HH events was observed. Accuracy for identifying HH events was high in the simulated validation setting (88.5%) but relatively low in the real-life clinical setting (52.4%). This difference was significant (P RFID system, almost half of the HH events were missed. More research is necessary to further develop these systems and improve accuracy prior to widespread adoption. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  9. New perspectives for high accuracy SLR with second generation geodesic satellites

    Science.gov (United States)

    Lund, Glenn

    1993-01-01

    This paper reports on the accuracy limitations imposed by geodesic satellite signatures, and on the potential for achieving millimetric performances by means of alternative satellite concepts and an optimized 2-color system tradeoff. Long distance laser ranging, when performed between a ground (emitter/receiver) station and a distant geodesic satellite, is now reputed to enable short arc trajectory determinations to be achieved with an accuracy of 1 to 2 centimeters. This state-of-the-art accuracy is limited principally by the uncertainties inherent to single-color atmospheric path length correction. Motivated by the study of phenomena such as postglacial rebound, and the detailed analysis of small-scale volcanic and strain deformations, the drive towards millimetric accuracies will inevitably be felt. With the advent of short pulse (less than 50 ps) dual wavelength ranging, combined with adequate detection equipment (such as a fast-scanning streak camera or ultra-fast solid-state detectors) the atmospheric uncertainty could potentially be reduced to the level of a few millimeters, thus, exposing other less significant error contributions, of which by far the most significant will then be the morphology of the retroreflector satellites themselves. Existing geodesic satellites are simply dense spheres, several 10's of cm in diameter, encrusted with a large number (426 in the case of LAGEOS) of small cube-corner reflectors. A single incident pulse, thus, results in a significant number of randomly phased, quasi-simultaneous return pulses. These combine coherently at the receiver to produce a convolved interference waveform which cannot, on a shot to shot basis, be accurately and unambiguously correlated to the satellite center of mass. This paper proposes alternative geodesic satellite concepts, based on the use of a very small number of cube-corner retroreflectors, in which the above difficulties are eliminated while ensuring, for a given emitted pulse, the return

  10. [Navigation in implantology: Accuracy assessment regarding the literature].

    Science.gov (United States)

    Barrak, Ibrahim Ádám; Varga, Endre; Piffko, József

    2016-06-01

    Our objective was to assess the literature regarding the accuracy of the different static guided systems. After applying electronic literature search we found 661 articles. After reviewing 139 articles, the authors chose 52 articles for full-text evaluation. 24 studies involved accuracy measurements. Fourteen of our selected references were clinical and ten of them were in vitro (modell or cadaver). Variance-analysis (Tukey's post-hoc test; p angular deviation was 3,96 degrees. Significant difference could be observed between the two methods of implant placement (partially and fully guided sequence) in terms of deviation at the entry point, apex and angular deviation. Different levels of quality and quantity of evidence were available for assessing the accuracy of the different computer-assisted implant placement. The rapidly evolving field of digital dentistry and the new developments will further improve the accuracy of guided implant placement. In the interest of being able to draw dependable conclusions and for the further evaluation of the parameters used for accuracy measurements, randomized, controlled single or multi-centered clinical trials are necessary.

  11. Reliability and accuracy of Crystaleye spectrophotometric system.

    Science.gov (United States)

    Chen, Li; Tan, Jian Guo; Zhou, Jian Feng; Yang, Xu; Du, Yang; Wang, Fang Ping

    2010-01-01

    to develop an in vitro shade-measuring model to evaluate the reliability and accuracy of the Crystaleye spectrophotometric system, a newly developed spectrophotometer. four shade guides, VITA Classical, VITA 3D-Master, Chromascop and Vintage Halo NCC, were measured with the Crystaleye spectrophotometer in a standardised model, ten times for 107 shade tabs. The shade-matching results and the CIE L*a*b* values of the cervical, body and incisal regions for each measurement were automatically analysed using the supporting software. Reliability and accuracy were calculated for each shade tab both in percentage and in colour difference (ΔE). Difference was analysed by one-way ANOVA in the cervical, body and incisal regions. range of reliability was 88.81% to 98.97% and 0.13 to 0.24 ΔE units, and that of accuracy was 44.05% to 91.25% and 1.03 to 1.89 ΔE units. Significant differences in reliability and accuracy were found between the body region and the cervical and incisal regions. Comparisons made among regions and shade guides revealed that evaluation in ΔE was prone to disclose the differences. measurements with the Crystaleye spectrophotometer had similar, high reliability in different shade guides and regions, indicating predictable repeated measurements. Accuracy in the body region was high and less variable compared with the cervical and incisal regions.

  12. Integral equation models for image restoration: high accuracy methods and fast algorithms

    International Nuclear Information System (INIS)

    Lu, Yao; Shen, Lixin; Xu, Yuesheng

    2010-01-01

    Discrete models are consistently used as practical models for image restoration. They are piecewise constant approximations of true physical (continuous) models, and hence, inevitably impose bottleneck model errors. We propose to work directly with continuous models for image restoration aiming at suppressing the model errors caused by the discrete models. A systematic study is conducted in this paper for the continuous out-of-focus image models which can be formulated as an integral equation of the first kind. The resulting integral equation is regularized by the Lavrentiev method and the Tikhonov method. We develop fast multiscale algorithms having high accuracy to solve the regularized integral equations of the second kind. Numerical experiments show that the methods based on the continuous model perform much better than those based on discrete models, in terms of PSNR values and visual quality of the reconstructed images

  13. Accuracy of abdominal auscultation for bowel obstruction

    DEFF Research Database (Denmark)

    Breum, Birger Michael; Rud, Bo; Kirkegaard, Thomas

    2015-01-01

    AIM: To investigate the accuracy and inter-observer variation of bowel sound assessment in patients with clinically suspected bowel obstruction. METHODS: Bowel sounds were recorded in patients with suspected bowel obstruction using a Littmann(®) Electronic Stethoscope. The recordings were process...

  14. Effect of data compression on diagnostic accuracy in digital hand and chest radiography

    Science.gov (United States)

    Sayre, James W.; Aberle, Denise R.; Boechat, Maria I.; Hall, Theodore R.; Huang, H. K.; Ho, Bruce K. T.; Kashfian, Payam; Rahbar, Guita

    1992-05-01

    Image compression is essential to handle a large volume of digital images including CT, MR, CR, and digitized films in a digital radiology operation. The full-frame bit allocation using the cosine transform technique developed during the last few years has been proven to be an excellent irreversible image compression method. This paper describes the effect of using the hardware compression module on diagnostic accuracy in hand radiographs with subperiosteal resorption and chest radiographs with interstitial disease. Receiver operating characteristic analysis using 71 hand radiographs and 52 chest radiographs with five observers each demonstrates that there is no statistical significant difference in diagnostic accuracy between the original films and the compressed images with a compression ratio as high as 20:1.

  15. Towards Building Reliable, High-Accuracy Solar Irradiance Database For Arid Climates

    Science.gov (United States)

    Munawwar, S.; Ghedira, H.

    2012-12-01

    Middle East's growing interest in renewable energy has led to increased activity in solar technology development with the recent commissioning of several utility-scale solar power projects and many other commercial installations across the Arabian Peninsula. The region, lying in a virtually rainless sunny belt with a typical daily average solar radiation exceeding 6 kWh/m2, is also one of the most promising candidates for solar energy deployment. However, it is not the availability of resource, but its characterization and reasonably accurate assessment that determines the application potential. Solar irradiance, magnitude and variability inclusive, is the key input in assessing the economic feasibility of a solar system. The accuracy of such data is of critical importance for realistic on-site performance estimates. This contribution aims to identify the key stages in developing a robust solar database for desert climate by focusing on the challenges that an arid environment presents to parameterization of solar irradiance attenuating factors. Adjustments are proposed based on the currently available resource assessment tools to produce high quality data for assessing bankability. Establishing and maintaining ground solar irradiance measurements is an expensive affair and fairly limited in time (recently operational) and space (fewer sites) in the Gulf region. Developers within solar technology industry, therefore, rely on solar radiation models and satellite-derived data for prompt resource assessment needs. It is imperative that such estimation tools are as accurate as possible. While purely empirical models have been widely researched and validated in the Arabian Peninsula's solar modeling history, they are known to be intrinsically site-specific. A primal step to modeling is an in-depth understanding of the region's climate, identifying the key players attenuating radiation and their appropriate characterization to determine solar irradiance. Physical approach

  16. HIGH ANGULAR RESOLUTION OBSERVATIONS OF FOUR CANDIDATE BLAST HIGH-MASS STARLESS CORES

    International Nuclear Information System (INIS)

    Olmi, Luca; Poventud, Carlos M.; Araya, Esteban D.; Chapin, Edward L.; Gibb, Andrew; Hofner, Peter; Martin, Peter G.

    2010-01-01

    We discuss high angular resolution observations of ammonia toward four candidate high-mass starless cores (HMSCs). The cores were identified by the Balloon-borne Large Aperture Submillimeter Telescope (BLAST) during its 2005 survey of the Vulpecula region where 60 compact sources were detected simultaneously at 250, 350, and 500 μm. Four of these cores, with no IRAS-PSC or MSX counterparts, were mapped with the NRAO Very Large Array and observed with the Effelsberg 100 m telescope in the NH 3 (1,1) and (2,2) spectral lines. Our observations indicate that the four cores are cold (T k -1 . The four BLAST cores appear to be colder and more quiescent than other previously observed HMSC candidates, suggesting an earlier stage of evolution.

  17. Shifting visual perspective during memory retrieval reduces the accuracy of subsequent memories.

    Science.gov (United States)

    Marcotti, Petra; St Jacques, Peggy L

    2018-03-01

    Memories for events can be retrieved from visual perspectives that were never experienced, reflecting the dynamic and reconstructive nature of memories. Characteristics of memories can be altered when shifting from an own eyes perspective, the way most events are initially experienced, to an observer perspective, in which one sees oneself in the memory. Moreover, recent evidence has linked these retrieval-related effects of visual perspective to subsequent changes in memories. Here we examine how shifting visual perspective influences the accuracy of subsequent memories for complex events encoded in the lab. Participants performed a series of mini-events that were experienced from their own eyes, and were later asked to retrieve memories for these events while maintaining the own eyes perspective or shifting to an alternative observer perspective. We then examined how shifting perspective during retrieval modified memories by influencing the accuracy of recall on a final memory test. Across two experiments, we found that shifting visual perspective reduced the accuracy of subsequent memories and that reductions in vividness when shifting visual perspective during retrieval predicted these changes in the accuracy of memories. Our findings suggest that shifting from an own eyes to an observer perspective influences the accuracy of long-term memories.

  18. High-accuracy biodistribution analysis of adeno-associated virus variants by double barcode sequencing.

    Science.gov (United States)

    Marsic, Damien; Méndez-Gómez, Héctor R; Zolotukhin, Sergei

    2015-01-01

    Biodistribution analysis is a key step in the evaluation of adeno-associated virus (AAV) capsid variants, whether natural isolates or produced by rational design or directed evolution. Indeed, when screening candidate vectors, accurate knowledge about which tissues are infected and how efficiently is essential. We describe the design, validation, and application of a new vector, pTR-UF50-BC, encoding a bioluminescent protein, a fluorescent protein and a DNA barcode, which can be used to visualize localization of transduction at the organism, organ, tissue, or cellular levels. In addition, by linking capsid variants to different barcoded versions of the vector and amplifying the barcode region from various tissue samples using barcoded primers, biodistribution of viral genomes can be analyzed with high accuracy and efficiency.

  19. Spline-based high-accuracy piecewise-polynomial phase-to-sinusoid amplitude converters.

    Science.gov (United States)

    Petrinović, Davor; Brezović, Marko

    2011-04-01

    We propose a method for direct digital frequency synthesis (DDS) using a cubic spline piecewise-polynomial model for a phase-to-sinusoid amplitude converter (PSAC). This method offers maximum smoothness of the output signal. Closed-form expressions for the cubic polynomial coefficients are derived in the spectral domain and the performance analysis of the model is given in the time and frequency domains. We derive the closed-form performance bounds of such DDS using conventional metrics: rms and maximum absolute errors (MAE) and maximum spurious free dynamic range (SFDR) measured in the discrete time domain. The main advantages of the proposed PSAC are its simplicity, analytical tractability, and inherent numerical stability for high table resolutions. Detailed guidelines for a fixed-point implementation are given, based on the algebraic analysis of all quantization effects. The results are verified on 81 PSAC configurations with the output resolutions from 5 to 41 bits by using a bit-exact simulation. The VHDL implementation of a high-accuracy DDS based on the proposed PSAC with 28-bit input phase word and 32-bit output value achieves SFDR of its digital output signal between 180 and 207 dB, with a signal-to-noise ratio of 192 dB. Its implementation requires only one 18 kB block RAM and three 18-bit embedded multipliers in a typical field-programmable gate array (FPGA) device. © 2011 IEEE

  20. Accuracy assessment of ALOS optical instruments: PRISM and AVNIR-2

    Science.gov (United States)

    Tadono, Takeo; Shimada, Masanobu; Iwata, Takanori; Takaku, Junichi; Kawamoto, Sachi

    2017-11-01

    This paper describes the updated results of calibration and validation to assess the accuracies for optical instruments onboard the Advanced Land Observing Satellite (ALOS, nicknamed "Daichi"), which was successfully launched on January 24th, 2006 and it is continuously operating very well. ALOS has an L-band Synthetic Aperture Radar called PALSAR and two optical instruments i.e. the Panchromatic Remotesensing Instrument for Stereo Mapping (PRISM) and the Advanced Visible and Near Infrared Radiometer type-2 (AVNIR-2). PRISM consists of three radiometers and is used to derive a digital surface model (DSM) with high spatial resolution that is an objective of the ALOS mission. Therefore, geometric calibration is important in generating a precise DSM with stereo pair images of PRISM. AVNIR-2 has four radiometric bands from blue to near infrared and uses for regional environment and disaster monitoring etc. The radiometric calibration and image quality evaluation are also important for AVNIR-2 as well as PRISM. This paper describes updated results of geometric calibration including geolocation determination accuracy evaluations of PRISM and AVNIR-2, image quality evaluation of PRISM, and validation of generated PRISM DSM. These works will be done during the ALOS mission life as an operational calibration to keep absolute accuracies of the standard products.

  1. A variational nodal diffusion method of high accuracy; Varijaciona nodalna difuziona metoda visoke tachnosti

    Energy Technology Data Exchange (ETDEWEB)

    Tomasevic, Dj; Altiparmarkov, D [Institut za Nuklearne Nauke Boris Kidric, Belgrade (Yugoslavia)

    1988-07-01

    A variational nodal diffusion method with accurate treatment of transverse leakage shape is developed and presented in this paper. Using Legendre expansion in transverse coordinates higher order quasi-one-dimensional nodal equations are formulated. Numerical solution has been carried out using analytical solutions in alternating directions assuming Legendre expansion of the RHS term. The method has been tested against 2D and 3D IAEA benchmark problem, as well as 2D CANDU benchmark problem. The results are highly accurate. The first order approximation yields to the same order of accuracy as the standard nodal methods with quadratic leakage approximation, while the second order reaches reference solution. (author)

  2. International VLBI Service for Geodesy and Astrometry 2014 Annual Report

    Science.gov (United States)

    Baver, Karen D. (Editor); Behrend, Dirk (Editor); Armstrong, Kyla L. (Editor)

    2015-01-01

    IVS is an international collaboration of organizations which operate or support Very Long Baseline Interferometry (VLBI) components. The goals are: 1. To provide a service to support geodetic, geophysical and astrometric research and operational activities. 2. To promote research and development activities in all aspects of the geodetic and astrometric VLBI technique. 3. To interact with the community of users of VLBI products and to integrate VLBI into a global Earth observing system.

  3. IVS Organization

    Science.gov (United States)

    2004-01-01

    International VLBI Service (IVS) is an international collaboration of organizations which operate or support Very Long Baseline Interferometry (VLBI) components. The goals are: To provide a service to support geodetic, geophysical and astrometric research and operational activities. To promote research and development activities in all aspects of the geodetic and astrometric VLBI technique. To interact with the community of users of VLBI products and to integrate VLBI into a global Earth observing system.

  4. Optical sensors for earth observation. Chikyu kansokuyo kogaku sensor

    Energy Technology Data Exchange (ETDEWEB)

    Ono, A [National Research Laboratory of Metrology, Tsukuba (Japan)

    1991-10-10

    Developments are made on an optical imager (ASTER) used to collect mainly images of land areas and an infrared sounder (IMG) to measure vertical air temperature distribution and vertical concentration distribution of specific gases, as satellite mounted sensors for earth observation. All the sensor characteristics of the ASTER comprising a visible near infrared radiometer, short wave infrared radiometer and thermal infrared radiometer are required to be capable of providing measurement, evaluation and assurance at the required accuracies during the entire life time. A problem to be solved is how to combine the on-ground calibration prior to launching, on-satellite calibration, and calibration between the test site and the sensors. The IMG is a Fourier transform spectroscopic infrared sounder, which is demanded of a high wave resolution over extended periods of time as well as a high radiation measuring capability. Also required are the level elevation of analysis algorithms to solve inverse problems from the observed radiation spectra, and the data base with high accuracy. 19 refs., 4 figs., 4 tabs.

  5. Accuracy Improvement of Discharge Measurement with Modification of Distance Made Good Heading

    Directory of Open Access Journals (Sweden)

    Jongkook Lee

    2016-01-01

    Full Text Available Remote control boats equipped with an Acoustic Doppler Current Profiler (ADCP are widely accepted and have been welcomed by many hydrologists for water discharge, velocity profile, and bathymetry measurements. The advantages of this technique include high productivity, fast measurements, operator safety, and high accuracy. However, there are concerns about controlling and operating a remote boat to achieve measurement goals, especially during extreme events such as floods. When performing river discharge measurements, the main error source stems from the boat path. Due to the rapid flow in a flood condition, the boat path is not regular and this can cause errors in discharge measurements. Therefore, improvement of discharge measurements requires modification of boat path. As a result, the measurement errors in flood flow conditions are 12.3–21.8% before the modification of boat path, but 1.2–3.7% after the DMG modification of boat path. And it is considered that the modified discharges are very close to the observed discharge in the flood flow conditions. In this study, through the distance made good (DMG modification of the boat path, a comprehensive discharge measurement with high accuracy can be achieved.

  6. Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions – Changes in Accuracy over Time

    Science.gov (United States)

    Lebel, Karina; Boissy, Patrick; Hamel, Mathieu; Duval, Christian

    2015-01-01

    Background Interest in 3D inertial motion tracking devices (AHRS) has been growing rapidly among the biomechanical community. Although the convenience of such tracking devices seems to open a whole new world of possibilities for evaluation in clinical biomechanics, its limitations haven’t been extensively documented. The objectives of this study are: 1) to assess the change in absolute and relative accuracy of multiple units of 3 commercially available AHRS over time; and 2) to identify different sources of errors affecting AHRS accuracy and to document how they may affect the measurements over time. Methods This study used an instrumented Gimbal table on which AHRS modules were carefully attached and put through a series of velocity-controlled sustained motions including 2 minutes motion trials (2MT) and 12 minutes multiple dynamic phases motion trials (12MDP). Absolute accuracy was assessed by comparison of the AHRS orientation measurements to those of an optical gold standard. Relative accuracy was evaluated using the variation in relative orientation between modules during the trials. Findings Both absolute and relative accuracy decreased over time during 2MT. 12MDP trials showed a significant decrease in accuracy over multiple phases, but accuracy could be enhanced significantly by resetting the reference point and/or compensating for initial Inertial frame estimation reference for each phase. Interpretation The variation in AHRS accuracy observed between the different systems and with time can be attributed in part to the dynamic estimation error, but also and foremost, to the ability of AHRS units to locate the same Inertial frame. Conclusions Mean accuracies obtained under the Gimbal table sustained conditions of motion suggest that AHRS are promising tools for clinical mobility assessment under constrained conditions of use. However, improvement in magnetic compensation and alignment between AHRS modules are desirable in order for AHRS to reach their

  7. Optical monitoring of QSO in the framework of the Gaia space mission

    Science.gov (United States)

    Taris, F.; Damljanovic, G.; Andrei, A.; Klotz, A.; Vachier, F.

    2015-08-01

    The Gaia astrometric mission of the European Space Agency has been launched the 19th December 2013. It will provide an astrometric catalogue of 500 000 extragalactic sources that could be the basis of a new optical reference frame. On the other hand, the current International Celestial Reference Frame (ICRF) is based on the observations of extragalactic sources at radio wavelength. The astrometric coordinates of sources in these two reference systems will have roughly the same uncertainty. It is then mandatory to observe a set of common targets at both optical and radio wavelength to link the ICRF with what could be called the GCRF (Gaia Celestial Reference Frame). We will show in this paper some results obtained with the TJO, Telescopi Juan Oro, from Observatori Astronomic del Montsec in Spain. It also presents some results obtained with the Lomb-Scargle and CLEAN algorithm methods applied to optical magnitude obtained with the TAROT telescopes.

  8. Improving decision speed, accuracy and group cohesion through early information gathering in house-hunting ants.

    Science.gov (United States)

    Stroeymeyt, Nathalie; Giurfa, Martin; Franks, Nigel R

    2010-09-29

    Successful collective decision-making depends on groups of animals being able to make accurate choices while maintaining group cohesion. However, increasing accuracy and/or cohesion usually decreases decision speed and vice-versa. Such trade-offs are widespread in animal decision-making and result in various decision-making strategies that emphasize either speed or accuracy, depending on the context. Speed-accuracy trade-offs have been the object of many theoretical investigations, but these studies did not consider the possible effects of previous experience and/or knowledge of individuals on such trade-offs. In this study, we investigated how previous knowledge of their environment may affect emigration speed, nest choice and colony cohesion in emigrations of the house-hunting ant Temnothorax albipennis, a collective decision-making process subject to a classical speed-accuracy trade-off. Colonies allowed to explore a high quality nest site for one week before they were forced to emigrate found that nest and accepted it faster than emigrating naïve colonies. This resulted in increased speed in single choice emigrations and higher colony cohesion in binary choice emigrations. Additionally, colonies allowed to explore both high and low quality nest sites for one week prior to emigration remained more cohesive, made more accurate decisions and emigrated faster than emigrating naïve colonies. These results show that colonies gather and store information about available nest sites while their nest is still intact, and later retrieve and use this information when they need to emigrate. This improves colony performance. Early gathering of information for later use is therefore an effective strategy allowing T. albipennis colonies to improve simultaneously all aspects of the decision-making process--i.e. speed, accuracy and cohesion--and partly circumvent the speed-accuracy trade-off classically observed during emigrations. These findings should be taken into account

  9. Accuracy of taxonomy prediction for 16S rRNA and fungal ITS sequences

    Directory of Open Access Journals (Sweden)

    Robert C. Edgar

    2018-04-01

    Full Text Available Prediction of taxonomy for marker gene sequences such as 16S ribosomal RNA (rRNA is a fundamental task in microbiology. Most experimentally observed sequences are diverged from reference sequences of authoritatively named organisms, creating a challenge for prediction methods. I assessed the accuracy of several algorithms using cross-validation by identity, a new benchmark strategy which explicitly models the variation in distances between query sequences and the closest entry in a reference database. When the accuracy of genus predictions was averaged over a representative range of identities with the reference database (100%, 99%, 97%, 95% and 90%, all tested methods had ≤50% accuracy on the currently-popular V4 region of 16S rRNA. Accuracy was found to fall rapidly with identity; for example, better methods were found to have V4 genus prediction accuracy of ∼100% at 100% identity but ∼50% at 97% identity. The relationship between identity and taxonomy was quantified as the probability that a rank is the lowest shared by a pair of sequences with a given pair-wise identity. With the V4 region, 95% identity was found to be a twilight zone where taxonomy is highly ambiguous because the probabilities that the lowest shared rank between pairs of sequences is genus, family, order or class are approximately equal.

  10. Investigating circular patterns in linear polarization observations of Venus

    NARCIS (Netherlands)

    Mahapatra, G.; Stam, D.M.; Rossi, L.C.G.; Rodenhuis, M.; Snik, Frans; Keller, C.U.

    2017-01-01

    In this work, we analyse linear polarization data of the planet at a distance, obtained with the Extreme Polarimeter (ExPo) on the William Herschel Telescope
    on La Palma. These spatially resolved, high-accuracy polarization observations of Venus show faint circular patterns centered on the

  11. Kinematic-PPP using Single/Dual Frequency Observations from (GPS, GLONASS and GPS/GLONASS) Constellations for Hydrography

    Science.gov (United States)

    Farah, Ashraf

    2018-03-01

    Global Positioning System (GPS) technology is ideally suited for inshore and offshore positioning because of its high accuracy and the short observation time required for a position fix. Precise point positioning (PPP) is a technique used for position computation with a high accuracy using a single GNSS receiver. It relies on highly accurate satellite position and clock data that can be acquired from different sources such as the International GNSS Service (IGS). PPP precision varies based on positioning technique (static or kinematic), observations type (single or dual frequency) and the duration of observations among other factors. PPP offers comparable accuracy to differential GPS with safe in cost and time. For many years, PPP users depended on GPS (American system) which considered the solely reliable system. GLONASS's contribution in PPP techniques was limited due to fail in maintaining full constellation. Yet, GLONASS limited observations could be integrated into GPS-based PPP to improve availability and precision. As GLONASS reached its full constellation early 2013, there is a wide interest in PPP systems based on GLONASS only and independent of GPS. This paper investigates the performance of kinematic PPP solution for the hydrographic applications in the Nile river (Aswan, Egypt) based on GPS, GLONASS and GPS/GLONASS constellations. The study investigates also the effect of using two different observation types; single-frequency and dual frequency observations from the tested constellations.

  12. Accuracy of MR imaging in partial tears of rotator cuff

    International Nuclear Information System (INIS)

    Eto, Masao; Ito, Nobuyuki; Tomonaga, Tadashi; Harada, Shin'ichi; Rabbi, M.E.; Iwasaki, Katsuro

    1997-01-01

    MRI is very useful for the diagnosis of the rotator cuff tear However. in case of partial tears it is sometimes controvertible. In this study, we studied the accuracy of MRI in the diagnosis of partial tears. 67 patients who underwent MRI investigation before operation were chosen for this study. There were 61 males and 6 females, ranging from 30 to 80 years (mean: 54.8 years at the time of operation). MRI was performed with 1.5T superconductive system with shoulder surface coil. MPGR T2-weighted images were performed in the coronal oblique and sagittal oblique planes. Complete tears were diagnosed when full thickness high intensity was observed in the rotator cuff, whereas with partial high intensity of the rotator cuff, was considered as partial tears. MRI demonstrated 77.8% sensitivity, 91.4% specificity and 89.6% accuracy in the diagnosis of partial tear. In 8 cases MRI had misinterpretation. In MPGR T2-weighted images, not only the partial tears but the degenerative changes also show high intensity of the rotator cuff. Therefore, it is difficult to differentiate and maybe this is the reason of misinterpretations of partial tears by MRI. MRI provided with useful pre-operative informations of partial tears of the rotator cuff. However, in few cases it is hard to differentiate for the degenerative changes of the rotator cuff. (author)

  13. PreCam: A Precursor Observational Campaign for Calibration of the Dark Energy Survey

    Energy Technology Data Exchange (ETDEWEB)

    Kuehn, K.; Kuhlmann, S.; Allam, S.; Annis, J. T.; Bailey, T.; Balbinot, E.; Bernstein, J. P.; Biesiadzinski, T.; Burke, D. L.; Butner, M.; Camargo, J. I. B.; da Costa, L. A. N.; DePoy, D.; Diehl, H. T.; Dietrich, J. P.; Estrada, J.; Fausti, A.; Gerke, B.; Guarino, V.; Head, H. H.; Kessler, R.; Lin, H.; Lorenzon, W.; Maia, M. A. G.; Maki, L.; Marshall, J.; Nord, B.; Neilsen, E.; Ogando, R. L. C.; Park, D.; Peoples, J.; Rastawicki, D.; Rheault, J. -P.; Santiago, B.; Schubnell, M.; Seitzer, P.; Smith, J. A.; Spinka, H.; Sypniewski, A.; Tarle, G.; Tucker, D. L.; Walker, A. R.; Wester, W.

    2013-04-01

    PreCam, a precursor observational campaign supporting the Dark Energy Survey (DES), is designed to produce a photometric and astrometric catalog of nearly a hundred thousand standard stars within the DES footprint, while the PreCam instrument also serves as a prototype testbed for the Dark Energy Camera's hardware and software. This catalog represents a potential 100-fold increase in Southern Hemisphere photometric standard stars, and therefore will be an important component in the calibration of the Dark Energy Survey. We provide details on the PreCam instrument's design, construction, and testing, as well as results from a subset of the 51 nights of PreCam survey observations on the University of Michigan Department of Astronomy's Curtis-Schmidt telescope at Cerro Tololo Inter-American Observatory (CTIO). We briefly describe the preliminary data processing pipeline that has been developed for PreCam data and the preliminary results of the instrument performance, as well as astrometry and photometry of a sample of stars previously included in other southern sky surveys.

  14. Strong coupling constant extraction from high-multiplicity Z +jets observables

    Science.gov (United States)

    Johnson, Mark; Maître, Daniel

    2018-03-01

    We present a strong coupling constant extraction at next-to-leading order QCD accuracy using ATLAS Z +2 ,3,4 jets data. This is the first extraction using processes with a dependency on high powers of the coupling constant. We obtain values of the strong coupling constant at the Z mass compatible with the world average and with uncertainties commensurate with other next-to-leading order extractions at hadron colliders. Our most conservative result for the strong coupling constant is αS(MZ)=0.117 8-0.0043+0.0051 .

  15. Observation Status, Poverty, and High Financial Liability Among Medicare Beneficiaries.

    Science.gov (United States)

    Goldstein, Jennifer N; Zhang, Zugui; Schwartz, J Sanford; Hicks, LeRoi S

    2018-01-01

    Medicare beneficiaries hospitalized under observation status are subject to cost-sharing with no spending limit under Medicare Part B. Because low-income status is associated with increased hospital use, there is concern that such beneficiaries may be at increased risk for high use and out-of-pocket costs related to observation care. Our objective was to determine whether low-income Medicare beneficiaries are at risk for high use and high financial liability for observation care compared with higher-income beneficiaries. We performed a retrospective, observational analysis of Medicare Part B claims and US Census Bureau data from 2013. Medicare beneficiaries with Part A and B coverage for the full calendar year, with 1 or more observation stay(s), were included in the study. Beneficiaries were divided into quartiles representing poverty level. The associations between poverty quartile and high use of observation care and between poverty quartile and high financial liability for observation care were evaluated. After multivariate adjustment, the risk of high use was higher for beneficiaries in the poor (Quartile 3) and poorest (Quartile 4) quartiles compared with those in the wealthiest quartile (Quartile 1) (adjusted odds ratio [AOR], 1.21; 95% confidence interval [CI], 1.13-1.31; AOR, 1.24; 95% CI, 1.16-1.33). The risk of high financial liability was higher in every poverty quartile compared with the wealthiest and peaked in Quartile 3, which represented the poor but not the poorest beneficiaries (AOR, 1.17; 95% CI, 1.10-1.24). Poverty predicts high use of observation care. The poor or near poor may be at highest risk for high liability. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Coorientational Accuracy and Differentiation in the Management of Conflict.

    Science.gov (United States)

    Papa, Michael J.; Pood, Elliott A.

    1988-01-01

    Investigates the relationship between coorientational accuracy and differentiation time and two dimensions of conflict (interaction satisfaction and assertiveness of influence strategies). Suggests that entering a conflict with high coorientational accuracy leads to less differentiation and fewer assertive strategies during the confrontation and…

  17. COS-B observation of the milky way in high-energy gamma rays

    International Nuclear Information System (INIS)

    Mayer-Hasselwander, H.A.; Lebrun, F.; Masnou, J.L.

    1978-01-01

    The Caravane Collaboration's gamma-ray astronomy experiment aboard ESA's satellite COS-B has been recording celestial gamma rays in the energy range from about 50 MeV to several GeV since August 1975. These observations covers the whole range of galactic longitude, thus making it possible to present here the first complete detailed gamma-ray survey of the Milky Way with greatly improved statistical accuracy and significantly better energy measurement than in the previous survey. The present work concentrates on the spatial aspects of the gamma radiation, including localised sources

  18. A content analysis of the quantity and accuracy of dietary supplement information found in magazines with high adolescent readership.

    Science.gov (United States)

    Shaw, Patricia; Zhang, Vivien; Metallinos-Katsaras, Elizabeth

    2009-02-01

    The objective of this study was to examine the quantity and accuracy of dietary supplement (DS) information through magazines with high adolescent readership. Eight (8) magazines (3 teen and 5 adult with high teen readership) were selected. A content analysis for DS was conducted on advertisements and editorials (i.e., articles, advice columns, and bulletins). Noted claims/cautions regarding DS were evaluated for accuracy using Medlineplus.gov and Naturaldatabase.com. Claims for dietary supplements with three or more types of ingredients and those in advertisements were not evaluated. Advertisements were evaluated with respect to size, referenced research, testimonials, and Dietary Supplement Health and Education Act of 1994 (DSHEA) warning visibility. Eighty-eight (88) issues from eight magazines yielded 238 DS references. Fifty (50) issues from five magazines contained no DS reference. Among teen magazines, seven DS references were found: five in the editorials and two in advertisements. In adult magazines, 231 DS references were found: 139 in editorials and 92 in advertisements. Of the 88 claims evaluated, 15% were accurate, 23% were inconclusive, 3% were inaccurate, 5% were partially accurate, and 55% were unsubstantiated (i.e., not listed in reference databases). Of the 94 DS evaluated in advertisements, 43% were full page or more, 79% did not have a DSHEA warning visible, 46% referred to research, and 32% used testimonials. Teen magazines contain few references to DS, none accurate. Adult magazines that have a high teen readership contain a substantial amount of DS information with questionable accuracy, raising concerns that this information may increase the chances of inappropriate DS use by adolescents, thereby increasing the potential for unexpected effects or possible harm.

  19. High spectral resolution X-ray observations of AGN

    NARCIS (Netherlands)

    Kaastra, J.S.

    2008-01-01

    brief overview of some highlights of high spectral resolution X-ray observations of AGN is given, mainly obtained with the RGS of XMM-Newton. Future prospects for such observations with XMM-Newton are given.

  20. A vision for an ultra-high resolution integrated water cycle observation and prediction system

    Science.gov (United States)

    Houser, P. R.

    2013-05-01

    Society's welfare, progress, and sustainable economic growth—and life itself—depend on the abundance and vigorous cycling and replenishing of water throughout the global environment. The water cycle operates on a continuum of time and space scales and exchanges large amounts of energy as water undergoes phase changes and is moved from one part of the Earth system to another. We must move toward an integrated observation and prediction paradigm that addresses broad local-to-global science and application issues by realizing synergies associated with multiple, coordinated observations and prediction systems. A central challenge of a future water and energy cycle observation strategy is to progress from single variable water-cycle instruments to multivariable integrated instruments in electromagnetic-band families. The microwave range in the electromagnetic spectrum is ideally suited for sensing the state and abundance of water because of water's dielectric properties. Eventually, a dedicated high-resolution water-cycle microwave-based satellite mission may be possible based on large-aperture antenna technology that can harvest the synergy that would be afforded by simultaneous multichannel active and passive microwave measurements. A partial demonstration of these ideas can even be realized with existing microwave satellite observations to support advanced multivariate retrieval methods that can exploit the totality of the microwave spectral information. The simultaneous multichannel active and passive microwave retrieval would allow improved-accuracy retrievals that are not possible with isolated measurements. Furthermore, the simultaneous monitoring of several of the land, atmospheric, oceanic, and cryospheric states brings synergies that will substantially enhance understanding of the global water and energy cycle as a system. The multichannel approach also affords advantages to some constituent retrievals—for instance, simultaneous retrieval of vegetation

  1. Spacecraft Angular Rates Estimation with Gyrowheel Based on Extended High Gain Observer

    Directory of Open Access Journals (Sweden)

    Xiaokun Liu

    2016-04-01

    Full Text Available A gyrowheel (GW is a kind of electronic electric-mechanical servo system, which can be applied to a spacecraft attitude control system (ACS as both an actuator and a sensor simultaneously. In order to solve the problem of two-dimensional spacecraft angular rate sensing as a GW outputting three-dimensional control torque, this paper proposed a method of an extended high gain observer (EHGO with the derived GW mathematical model to implement the spacecraft angular rate estimation when the GW rotor is working at large angles. For this purpose, the GW dynamic equation is firstly derived with the second kind Lagrange method, and the relationship between the measurable and unmeasurable variables is built. Then, the EHGO is designed to estimate and calculate spacecraft angular rates with the GW, and the stability of the designed EHGO is proven by the Lyapunov function. Moreover, considering the engineering application, the effect of measurement noise in the tilt angle sensors on the estimation accuracy of the EHGO is analyzed. Finally, the numerical simulation is performed to illustrate the validity of the method proposed in this paper.

  2. Accuracy assessment of high resolution satellite imagery orientation by leave-one-out method

    Science.gov (United States)

    Brovelli, Maria Antonia; Crespi, Mattia; Fratarcangeli, Francesca; Giannone, Francesca; Realini, Eugenio

    Interest in high-resolution satellite imagery (HRSI) is spreading in several application fields, at both scientific and commercial levels. Fundamental and critical goals for the geometric use of this kind of imagery are their orientation and orthorectification, processes able to georeference the imagery and correct the geometric deformations they undergo during acquisition. In order to exploit the actual potentialities of orthorectified imagery in Geomatics applications, the definition of a methodology to assess the spatial accuracy achievable from oriented imagery is a crucial topic. In this paper we want to propose a new method for accuracy assessment based on the Leave-One-Out Cross-Validation (LOOCV), a model validation method already applied in different fields such as machine learning, bioinformatics and generally in any other field requiring an evaluation of the performance of a learning algorithm (e.g. in geostatistics), but never applied to HRSI orientation accuracy assessment. The proposed method exhibits interesting features which are able to overcome the most remarkable drawbacks involved by the commonly used method (Hold-Out Validation — HOV), based on the partitioning of the known ground points in two sets: the first is used in the orientation-orthorectification model (GCPs — Ground Control Points) and the second is used to validate the model itself (CPs — Check Points). In fact the HOV is generally not reliable and it is not applicable when a low number of ground points is available. To test the proposed method we implemented a new routine that performs the LOOCV in the software SISAR, developed by the Geodesy and Geomatics Team at the Sapienza University of Rome to perform the rigorous orientation of HRSI; this routine was tested on some EROS-A and QuickBird images. Moreover, these images were also oriented using the world recognized commercial software OrthoEngine v. 10 (included in the Geomatica suite by PCI), manually performing the LOOCV

  3. Drinking behavior in nursery pigs: determining the accuracy between an automatic water meter versus human observers.

    Science.gov (United States)

    Meiszberg, A M; Johnson, A K; Sadler, L J; Carroll, J A; Dailey, J W; Krebs, N

    2009-12-01

    Assimilating accurate behavioral events over a long period can be labor-intensive and relatively expensive. If an automatic device could accurately record the duration and frequency for a given behavioral event, it would be a valuable alternative to the traditional use of human observers for behavioral studies. Therefore, the objective of this study was to determine the accuracy in the time spent at the waterer and the number of visits to the waterer by individually housed nursery pigs between human observers scoring video files using Observer software (OBS) and an automatic water meter Hobo (WM, control) affixed onto the waterline. Eleven PIC USA genotype gilts (22 +/- 2 d of age; 6.5 +/- 1.4 kg of BW) were housed individually in pens with ad libitum access to a corn-based starter ration and one nipple waterer. Behavior was collected on d 0 (day of weaning), 7, and 14 of the trial using 1 color camera positioned over 4 attached pens and a RECO-204 DVR at 1 frame per second. For the OBS method, 2 experienced observers recorded drinking behavior from the video files, which was defined as when the gilt placed her mouth over the nipple waterer. Data were analyzed using nonparametric methods and the general linear model and regression procedures in SAS. The experimental unit was the individual pen housing 1 gilt. The GLM model included the method of observation (WM vs. OBS) and time (24 h) as variables, and the gilt nested within method was used as the error term. Gilts consumed more water (P = 0.04) on d 14 than on d 0. The time of day affected (P waterer regardless of the method. However, the OBS method underestimated (P waterer (3.48 +/- 0.33 visits/h for OBS vs. 4.94 +/- 0.33 for WM) and overestimated (P waterer (22.6 +/- 1.46 s/h for OBS vs. 13.9 +/- 1.43 for WM) compared with WM. The relationship between the 2 methods for prediction of time spent at the waterer and number of visits made by the gilts was weak (R(2) = 0.56 and 0.69, respectively). Collectively

  4. Diagnostic Accuracy of 64Copper Prostate-specific Membrane Antigen Positron Emission Tomography/Computed Tomography for Primary Lymph Node Staging of Intermediate- to High-risk Prostate Cancer: Our Preliminary Experience.

    Science.gov (United States)

    Cantiello, Francesco; Gangemi, Vincenzo; Cascini, Giuseppe Lucio; Calabria, Ferdinando; Moschini, Marco; Ferro, Matteo; Musi, Gennaro; Butticè, Salvatore; Salonia, Andrea; Briganti, Alberto; Damiano, Rocco

    2017-08-01

    To assess the diagnostic accuracy of 64 Copper prostate-specific membrane antigen ( 64 Cu-PSMA) positron emission tomography/computed tomography (PET/CT) in the primary lymph node (LN) staging of a selected cohort of intermediate- to high-risk prostate cancer (PCa) patients. An observational prospective study was performed in 23 patients with intermediate- to high-risk PCa, who underwent 64 Cu-PSMA PET/CT for local and lymph nodal staging before laparoscopic radical prostatectomy with an extended pelvic LN dissection. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for LN status of 64 Cu-PSMA PET/CT were calculated using the final pathological findings as reference. Furthermore, we evaluated the correlation of intraprostatic tumor extent and grading with 64 Cu-PSMA intraprostatic distribution. Pathological analysis of LN involvement in 413 LNs harvested from our study cohort identified a total of 22 LN metastases in 8 (5%) of the 23 (35%) PCa patients. Imaging-based LN staging in a per-patient analysis showed that 64 Cu-PSMA PET/CT was positive in 7 of 8 LN-positive patients (22%) with a sensitivity of 87.5%, specificity of 100%, PPV of 100%, and NPV of 93.7%, considering the maximum standardized uptake value (SUV max ) at 4 hours as our reference. Receiver operating characteristic curve was characterized by an area under the curve of 0.938. A significant positive association was observed between SUV max at 4 hours with Gleason score, index, and cumulative tumor volume. In our intermediate- to high-risk PCa patients study cohort, we showed the high diagnostic accuracy of 64 Cu-PSMA PET/CT for primary LN staging before radical prostatectomy. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Real-Time Tropospheric Product Establishment and Accuracy Assessment in China

    Science.gov (United States)

    Chen, M.; Guo, J.; Wu, J.; Song, W.; Zhang, D.

    2018-04-01

    Tropospheric delay has always been an important issue in Global Navigation Satellite System (GNSS) processing. Empirical tropospheric delay models are difficult to simulate complex and volatile atmospheric environments, resulting in poor accuracy of the empirical model and difficulty in meeting precise positioning demand. In recent years, some scholars proposed to establish real-time tropospheric product by using real-time or near-real-time GNSS observations in a small region, and achieved some good results. This paper uses real-time observing data of 210 Chinese national GNSS reference stations to estimate the tropospheric delay, and establishes ZWD grid model in the country wide. In order to analyze the influence of tropospheric grid product on wide-area real-time PPP, this paper compares the method of taking ZWD grid product as a constraint with the model correction method. The results show that the ZWD grid product estimated based on the national reference stations can improve PPP accuracy and convergence speed. The accuracy in the north (N), east (E) and up (U) direction increase by 31.8 %,15.6 % and 38.3 %, respectively. As with the convergence speed, the accuracy of U direction experiences the most improvement.

  6. High Resolution Active Optics Observations from the Kepler Follow-up Observation Program

    Science.gov (United States)

    Gautier, Thomas N.; Ciardi, D. R.; Marcy, G. W.; Hirsch, L.

    2014-01-01

    The ground based follow-up observation program for candidate exoplanets discovered with the Kepler observatory has supported a major effort for high resolution imaging of candidate host stars using adaptive optics wave-front correction (AO), speckle imaging and lucky imaging. These images allow examination of the sky as close as a few tenths of an arcsecond from the host stars to detect background objects that might be the source of the Kepler transit signal instead of the host star. This poster reports on the imaging done with AO cameras on the Keck, Palomar 5m and Shane 3m (Lick Observatory) which have been used to obtain high resolution images of over 500 Kepler Object of Interest (KOI) exoplanet candidate host stars. All observations were made at near infrared wavelengths in the J, H and K bands, mostly using the host target star as the AO guide star. Details of the sensitivity to background objects actually attained by these observations and the number of background objects discovered are presented. Implications to the false positive rate of the Kepler candidates are discussed.

  7. Observational investigation of the solar oblateness

    International Nuclear Information System (INIS)

    Stebbins, R.T.

    1975-01-01

    The solar oblateness provides important information for solar physics and experimental relativity. After the solar neutrino flux, the sun's shape is the most revealing probe of the solar interior. Rapidly rotating interiors suggested to explain the solar neutrino paradox produce sizeable oblatenesses. Certain types of surface phenomena can also be investigated with precision diameter measurements. The relativistic advance of Mercury's perihelion has long been the principal experimental support for Einstein's theory of general relativity. Recent measurements of the solar oblateness have suggested that the relativistic advance is smaller than originally thought due to a contribution from a solar mass quadrupole moment. This interpretation of the perihelion advance would shift the experimental support to the scalar-tensor theory of gravitation. A debate over the interpretation of the oblateness measurements has resulted. In light of these circumstances, solar oblateness observations have been attempted. Improved experimental techniques have been devised, including a daytime astrometric telescope and an explicit definition of the sun's edge. Observations reveal a time varying excess equatorial brightness, that is, a variation in the limb darkening function between equator and pole, which would preclude accurate interpretation of previous solar oblateness measurements. This vindicates the alternate interpretations of other solar oblateness measurements. From these results, it can be concluded that the Mercury perihelion evidence firmly supports Einstein's General Theory of Relativity, the solar interiors cannot be rotating fast enough to account for the low solar neutrino flux, and a time varying excess equatorial brightness exists

  8. Mass of the Local Group from Proper Motions of Distant Dwarf Galaxies

    Science.gov (United States)

    van der Marel, Roeland

    2010-09-01

    The Local Group and its two dominant spirals, the Milky Way and M31, have become the benchmark for testing many aspects of cosmological and galaxy formation theories, due to many exciting new discoveries in the past decade. However, it is difficult to put results in a proper cosmological context, because our knowledge of the mass M of the Local Group remains uncertain by a factor 4. In units of 10^{12} solar masses, a spherical infall model for the zero-velocity surface gives M 1.3; the sum of estimates for the Milky Way and M31 masses gives M 2.6; and the Local Group Timing argument for the M31 orbit gives M 5.6. It is possible to discriminate between the proposed masses by calculating the orbits of galaxies at the edge of the Local Group, which requires knowledge of transverse velocity components. We therefore propose to use ACS/WFC to determine the proper motions of the 4 dwarf galaxies near the edge of the Local Group {Cetus, Leo A, Tucana, Sag DIG} for which deep first epoch data {with 5-7 year time baselines} already exist in the HST Archive. Our team has extensive expertise with HST astrometric science, and our past/ongoing work for, e.g., Omega Cen, LMC/SMC and M31 show that the necessary astrometric accuracy is within the reach of HST's demonstrated capabilities. We have developed, tested, and published a new technique that uses compact background galaxies as astrometric reference sources, and we have already reduced the first epoch data. The final predicted transverse velocity accuracy, 36 km/s when averaged over the sample, will be sufficient to discriminate between each of the proposed Local Group masses at 2-sigma significance {4-sigma between the most extreme values}. Our project will yield the most accurate Local Group mass determination to date, and only HST can achieve the required accuracy.

  9. Social power facilitates the effect of prosocial orientation on empathic accuracy.

    Science.gov (United States)

    Côté, Stéphane; Kraus, Michael W; Cheng, Bonnie Hayden; Oveis, Christopher; van der Löwe, Ilmo; Lian, Hua; Keltner, Dacher

    2011-08-01

    Power increases the tendency to behave in a goal-congruent fashion. Guided by this theoretical notion, we hypothesized that elevated power would strengthen the positive association between prosocial orientation and empathic accuracy. In 3 studies with university and adult samples, prosocial orientation was more strongly associated with empathic accuracy when distinct forms of power were high than when power was low. In Study 1, a physiological indicator of prosocial orientation, respiratory sinus arrhythmia, exhibited a stronger positive association with empathic accuracy in a face-to-face interaction among dispositionally high-power individuals. In Study 2, experimentally induced prosocial orientation increased the ability to accurately judge the emotions of a stranger but only for individuals induced to feel powerful. In Study 3, a trait measure of prosocial orientation was more strongly related to scores on a standard test of empathic accuracy among employees who occupied high-power positions within an organization. Study 3 further showed a mediated relationship between prosocial orientation and career satisfaction through empathic accuracy among employees in high-power positions but not among employees in lower power positions. Discussion concentrates upon the implications of these findings for studies of prosociality, power, and social behavior.

  10. The Accuracy and Bias of Single-Step Genomic Prediction for Populations Under Selection

    Directory of Open Access Journals (Sweden)

    Wan-Ling Hsu

    2017-08-01

    Full Text Available In single-step analyses, missing genotypes are explicitly or implicitly imputed, and this requires centering the observed genotypes using the means of the unselected founders. If genotypes are only available for selected individuals, centering on the unselected founder mean is not straightforward. Here, computer simulation is used to study an alternative analysis that does not require centering genotypes but fits the mean μg of unselected individuals as a fixed effect. Starting with observed diplotypes from 721 cattle, a five-generation population was simulated with sire selection to produce 40,000 individuals with phenotypes, of which the 1000 sires had genotypes. The next generation of 8000 genotyped individuals was used for validation. Evaluations were undertaken with (J or without (N μg when marker covariates were not centered; and with (JC or without (C μg when all observed and imputed marker covariates were centered. Centering did not influence accuracy of genomic prediction, but fitting μg did. Accuracies were improved when the panel comprised only quantitative trait loci (QTL; models JC and J had accuracies of 99.4%, whereas models C and N had accuracies of 90.2%. When only markers were in the panel, the 4 models had accuracies of 80.4%. In panels that included QTL, fitting μg in the model improved accuracy, but had little impact when the panel contained only markers. In populations undergoing selection, fitting μg in the model is recommended to avoid bias and reduction in prediction accuracy due to selection.

  11. Observational drawing biases are predicted by biases in perception: Empirical support of the misperception hypothesis of drawing accuracy with respect to two angle illusions.

    Science.gov (United States)

    Ostrofsky, Justin; Kozbelt, Aaron; Cohen, Dale J

    2015-01-01

    We tested the misperception hypothesis of drawing errors, which states that drawing accuracy is strongly influenced by the perceptual encoding of a to-be-drawn stimulus. We used a highly controlled experimental paradigm in which nonartist participants made perceptual judgements and drawings of angles under identical stimulus exposure conditions. Experiment 1 examined the isosceles/scalene triangle angle illusion; congruent patterns of bias in the perception and drawing tasks were found for 40 and 60° angles, but not for 20 or 80° angles, providing mixed support for the misperception hypothesis. Experiment 2 examined shape constancy effects with respect to reproductions of single acute or obtuse angles; congruent patterns of bias in the perception and drawing tasks were found across a range of angles from 29 to 151°, providing strong support for the misperception hypothesis. In both experiments, perceptual and drawing biases were positively correlated. These results are largely consistent with the misperception hypothesis, suggesting that inaccurate perceptual encoding of angles is an important reason that nonartists err in drawing angles from observation.

  12. Merging thermal and microwave satellite observations for a high-resolution soil moisture data product

    Science.gov (United States)

    Many societal applications of soil moisture data products require high spatial resolution and numerical accuracy. Current thermal geostationary satellite sensors (GOES Imager and GOES-R ABI) could produce 2-16km resolution soil moisture proxy data. Passive microwave satellite radiometers (e.g. AMSR...

  13. High-lying neutron hole strengths observed in pick-up reactions

    International Nuclear Information System (INIS)

    Gales, S.

    1980-01-01

    Neutron-hole states in orbits well below the Fermi surface have been observed in a number of medium-heavy nuclei from A=90 to 209 using one nucleon pick-up reactions. The excitation energies, angular distributions of such broad and enhanced structures will be discussed. The fragmentation of the neutron-hole strengths as well as the spreading of such simple mode of excitations into more complex states are compared to recent calculations within the quasiparticle-phonon or the single particle-vibration coupling nuclear models. We report on recent measurements of J for inner-hole states in 89 Zr and 115 Sn 119 Sn using the analyzing power of the (p,d) and (d,t) reactions. Large enhancement of cross-sections are observed at high excitation energy in the study of the (p,t) reactions on Zr, Cd, Sn, Te and Sm isotopes. The systematic features of such high-lying excitation are related to the ones observed in one neutron pick-up experiments. The origin of such concentration of two neutron-hole strengths in Cd and Sn isotopes will be discussed. Preliminary results obtained in the study of the (α, 6 He) reaction at 218 MeV incident energy on 90 Zr, 118 Sn and 208 Pb targets are presented and compared to the (p,t) results. Finally the properties of hole-analog states populated in neutron pick-up reactions (from 90 Zr to 208 Pb) will be presented

  14. ACCURACY ASSESSMENT OF COASTAL TOPOGRAPHY DERIVED FROM UAV IMAGES

    Directory of Open Access Journals (Sweden)

    N. Long

    2016-06-01

    Full Text Available To monitor coastal environments, Unmanned Aerial Vehicle (UAV is a low-cost and easy to use solution to enable data acquisition with high temporal frequency and spatial resolution. Compared to Light Detection And Ranging (LiDAR or Terrestrial Laser Scanning (TLS, this solution produces Digital Surface Model (DSM with a similar accuracy. To evaluate the DSM accuracy on a coastal environment, a campaign was carried out with a flying wing (eBee combined with a digital camera. Using the Photoscan software and the photogrammetry process (Structure From Motion algorithm, a DSM and an orthomosaic were produced. Compared to GNSS surveys, the DSM accuracy is estimated. Two parameters are tested: the influence of the methodology (number and distribution of Ground Control Points, GCPs and the influence of spatial image resolution (4.6 cm vs 2 cm. The results show that this solution is able to reproduce the topography of a coastal area with a high vertical accuracy (< 10 cm. The georeferencing of the DSM require a homogeneous distribution and a large number of GCPs. The accuracy is correlated with the number of GCPs (use 19 GCPs instead of 10 allows to reduce the difference of 4 cm; the required accuracy should be dependant of the research problematic. Last, in this particular environment, the presence of very small water surfaces on the sand bank does not allow to improve the accuracy when the spatial resolution of images is decreased.

  15. The use of high accuracy NAA for the certification of NIST botanical standard reference materials

    International Nuclear Information System (INIS)

    Becker, D.A.; Greenberg, R.R.; Stone, S.F.

    1992-01-01

    Neutron activation analysis is one of many analytical techniques used at the National Institute of Standards and Technology (NIST) for the certification of NIST Standard Reference Materials (SRMs). NAA competes favorably with all other techniques because of it's unique capabilities for high accuracy even at very low concentrations for many elements. In this paper, instrumental and radiochemical NAA results are described for 25 elements in two new NIST SRMs, SRM 1515 (Apple Leaves) and SRM 1547 (Peach Leaves), and are compared to the certified values for 19 elements in these two new botanical reference materials. (author) 7 refs.; 4 tabs

  16. Evaluating arguments during instigations of defence motivation and accuracy motivation.

    Science.gov (United States)

    Liu, Cheng-Hong

    2017-05-01

    When people evaluate the strength of an argument, their motivations are likely to influence the evaluation. However, few studies have specifically investigated the influences of motivational factors on argument evaluation. This study examined the effects of defence and accuracy motivations on argument evaluation. According to the compatibility between the advocated positions of arguments and participants' prior beliefs and the objective strength of arguments, participants evaluated four types of arguments: compatible-strong, compatible-weak, incompatible-strong, and incompatible-weak arguments. Experiment 1 revealed that participants possessing a high defence motivation rated compatible-weak arguments as stronger and incompatible-strong ones as weaker than participants possessing a low defence motivation. However, the strength ratings between the high and low defence groups regarding both compatible-strong and incompatible-weak arguments were similar. Experiment 2 revealed that when participants possessed a high accuracy motivation, they rated compatible-weak arguments as weaker and incompatible-strong ones as stronger than when they possessed a low accuracy motivation. However, participants' ratings on both compatible-strong and incompatible-weak arguments were similar when comparing high and low accuracy conditions. The results suggest that defence and accuracy motivations are two major motives influencing argument evaluation. However, they primarily influence the evaluation results for compatible-weak and incompatible-strong arguments, but not for compatible-strong and incompatible-weak arguments. © 2016 The British Psychological Society.

  17. CARETS: A prototype regional environmental information system. Volume 6: Cost, accuracy and consistency comparisons of land use maps made from high-altitude aircraft photography and ERTS imagery

    Science.gov (United States)

    Alexander, R. H. (Principal Investigator); Fitzpatrick, K. A.

    1975-01-01

    The author has identified the following significant results. Level 2 land use maps produced at three scales (1:24,000, 1:100,000, and 1:250,000) from high altitude photography were compared with each other and with point data obtained in the field. The same procedures were employed to determine the accuracy of the Level 1 land use maps produced at 1:250,000 from high altitude photography and color composite ERTS imagery. Accuracy of the Level 2 maps was 84.9 percent at 1:24,000, 77.4 percent at 1:100,000 and 73.0 percent at 1:250,000. Accuracy of the Level 1 1:250,000 maps was 76.5 percent for aerial photographs and 69.5 percent for ERTS imagery. The cost of Level 2 land use mapping at 1:24,000 was found to be high ($11.93 per sq km). The cost of mapping at 1:100,000 ($1.75) was about two times as expensive as mapping at 1:250,000 ($.88), and the accuracy increased by only 4.4 percent.

  18. Accuracy of Genomic Selection in a Rice Synthetic Population Developed for Recurrent Selection Breeding.

    Directory of Open Access Journals (Sweden)

    Cécile Grenier

    Full Text Available Genomic selection (GS is a promising strategy for enhancing genetic gain. We investigated the accuracy of genomic estimated breeding values (GEBV in four inter-related synthetic populations that underwent several cycles of recurrent selection in an upland rice-breeding program. A total of 343 S2:4 lines extracted from those populations were phenotyped for flowering time, plant height, grain yield and panicle weight, and genotyped with an average density of one marker per 44.8 kb. The relative effect of the linkage disequilibrium (LD and minor allele frequency (MAF thresholds for selecting markers, the relative size of the training population (TP and of the validation population (VP, the selected trait and the genomic prediction models (frequentist and Bayesian on the accuracy of GEBVs was investigated in 540 cross validation experiments with 100 replicates. The effect of kinship between the training and validation populations was tested in an additional set of 840 cross validation experiments with a single genomic prediction model. LD was high (average r2 = 0.59 at 25 kb and decreased slowly, distribution of allele frequencies at individual loci was markedly skewed toward unbalanced frequencies (MAF average value 15.2% and median 9.6%, and differentiation between the four synthetic populations was low (FST ≤0.06. The accuracy of GEBV across all cross validation experiments ranged from 0.12 to 0.54 with an average of 0.30. Significant differences in accuracy were observed among the different levels of each factor investigated. Phenotypic traits had the biggest effect, and the size of the incidence matrix had the smallest. Significant first degree interaction was observed for GEBV accuracy between traits and all the other factors studied, and between prediction models and LD, MAF and composition of the TP. The potential of GS to accelerate genetic gain and breeding options to increase the accuracy of predictions are discussed.

  19. Analysis of the plasmodium falciparum proteome by high-accuracy mass spectrometry

    DEFF Research Database (Denmark)

    Lasonder, Edwin; Ishihama, Yasushi; Andersen, Jens S

    2002-01-01

    -accuracy (average deviation less than 0.02 Da at 1,000 Da) mass spectrometric proteome analysis of selected stages of the human malaria parasite Plasmodium falciparum. The analysis revealed 1,289 proteins of which 714 proteins were identified in asexual blood stages, 931 in gametocytes and 645 in gametes. The last...

  20. Experimental assessment of the accuracy of genomic selection in sugarcane.

    Science.gov (United States)

    Gouy, M; Rousselle, Y; Bastianelli, D; Lecomte, P; Bonnal, L; Roques, D; Efile, J-C; Rocher, S; Daugrois, J; Toubi, L; Nabeneza, S; Hervouet, C; Telismart, H; Denis, M; Thong-Chane, A; Glaszmann, J C; Hoarau, J-Y; Nibouche, S; Costet, L

    2013-10-01

    Sugarcane cultivars are interspecific hybrids with an aneuploid, highly heterozygous polyploid genome. The complexity of the sugarcane genome is the main obstacle to the use of marker-assisted selection in sugarcane breeding. Given the promising results of recent studies of plant genomic selection, we explored the feasibility of genomic selection in this complex polyploid crop. Genetic values were predicted in two independent panels, each composed of 167 accessions representing sugarcane genetic diversity worldwide. Accessions were genotyped with 1,499 DArT markers. One panel was phenotyped in Reunion Island and the other in Guadeloupe. Ten traits concerning sugar and bagasse contents, digestibility and composition of the bagasse, plant morphology, and disease resistance were used. We used four statistical predictive models: bayesian LASSO, ridge regression, reproducing kernel Hilbert space, and partial least square regression. The accuracy of the predictions was assessed through the correlation between observed and predicted genetic values by cross validation within each panel and between the two panels. We observed equivalent accuracy among the four predictive models for a given trait, and marked differences were observed among traits. Depending on the trait concerned, within-panel cross validation yielded median correlations ranging from 0.29 to 0.62 in the Reunion Island panel and from 0.11 to 0.5 in the Guadeloupe panel. Cross validation between panels yielded correlations ranging from 0.13 for smut resistance to 0.55 for brix. This level of correlations is promising for future implementations. Our results provide the first validation of genomic selection in sugarcane.

  1. Predictive accuracy of backpropagation neural network ...

    Indian Academy of Sciences (India)

    incorporated into the BP model for high accuracy management purpose of irrigation water, which relies on accurate values of ET ... as seen from the recent food crisis demonstra- tion in most .... layers by using Geographical Information System.

  2. High Accuracy Positioning using Jet Thrusters for Quadcopter

    Directory of Open Access Journals (Sweden)

    Pi ChenHuan

    2018-01-01

    Full Text Available A quadcopter is equipped with four additional jet thrusters on its horizontal plane and vertical to each other in order to improve the maneuverability and positioning accuracy of quadcopter. A dynamic model of the quadcopter with jet thrusters is derived and two controllers are implemented in simulation, one is a dual loop state feedback controller for pose control and another is an auxiliary jet thruster controller for accurate positioning. Step response simulations showed that the jet thruster can control the quadcopter with less overshoot compared to the conventional one. Over 10s loiter simulation with disturbance, the quadcopter with jet thruster decrease 85% of RMS error of horizontal disturbance compared to a conventional quadcopter with only a dual loop state feedback controller. The jet thruster controller shows the possibility for further accurate in the field of quadcopter positioning.

  3. Recent high-accuracy measurements of the 1S0 neutron-neutron scattering length

    International Nuclear Information System (INIS)

    Howell, C.R.; Chen, Q.; Gonzalez Trotter, D.E.; Salinas, F.; Crowell, A.S.; Roper, C.D.; Tornow, W.; Walter, R.L.; Carman, T.S.; Hussein, A.; Gibbs, W.R.; Gibson, B.F.; Morris, C.; Obst, A.; Sterbenz, S.; Whitton, M.; Mertens, G.; Moore, C.F.; Whiteley, C.R.; Pasyuk, E.; Slaus, I.; Tang, H.; Zhou, Z.; Gloeckle, W.; Witala, H.

    2000-01-01

    This paper reports two recent high-accuracy determinations of the 1 S 0 neutron-neutron scattering length, a nn . One was done at the Los Alamos National Laboratory using the π - d capture reaction to produce two neutrons with low relative momentum. The neutron-deuteron (nd) breakup reaction was used in other measurement, which was conducted at the Triangle Universities Nuclear Laboratory. The results from the two determinations were consistent with each other and with previous values obtained using the π - d capture reaction. The value obtained from the nd breakup measurements is a nn = -18.7 ± 0.1 (statistical) ± 0.6 (systematic) fm, and the value from the π - d capture experiment is a nn = -18.50 ± 0.05 ± 0.53 fm. The recommended value is a nn = -18.5 ± 0.3 fm. (author)

  4. Climatic associations of British species distributions show good transferability in time but low predictive accuracy for range change.

    Directory of Open Access Journals (Sweden)

    Giovanni Rapacciuolo

    Full Text Available Conservation planners often wish to predict how species distributions will change in response to environmental changes. Species distribution models (SDMs are the primary tool for making such predictions. Many methods are widely used; however, they all make simplifying assumptions, and predictions can therefore be subject to high uncertainty. With global change well underway, field records of observed range shifts are increasingly being used for testing SDM transferability. We used an unprecedented distribution dataset documenting recent range changes of British vascular plants, birds, and butterflies to test whether correlative SDMs based on climate change provide useful approximations of potential distribution shifts. We modelled past species distributions from climate using nine single techniques and a consensus approach, and projected the geographical extent of these models to a more recent time period based on climate change; we then compared model predictions with recent observed distributions in order to estimate the temporal transferability and prediction accuracy of our models. We also evaluated the relative effect of methodological and taxonomic variation on the performance of SDMs. Models showed good transferability in time when assessed using widespread metrics of accuracy. However, models had low accuracy to predict where occupancy status changed between time periods, especially for declining species. Model performance varied greatly among species within major taxa, but there was also considerable variation among modelling frameworks. Past climatic associations of British species distributions retain a high explanatory power when transferred to recent time--due to their accuracy to predict large areas retained by species--but fail to capture relevant predictors of change. We strongly emphasize the need for caution when using SDMs to predict shifts in species distributions: high explanatory power on temporally-independent records

  5. Visual selective attention is equally functional for individuals with low and high working memory capacity: evidence from accuracy and eye movements.

    Science.gov (United States)

    Mall, Jonathan T; Morey, Candice C; Wolff, Michael J; Lehnert, Franziska

    2014-10-01

    Selective attention and working memory capacity (WMC) are related constructs, but debate about the manner in which they are related remains active. One elegant explanation of variance in WMC is that the efficiency of filtering irrelevant information is the crucial determining factor, rather than differences in capacity per se. We examined this hypothesis by relating WMC (as measured by complex span tasks) to accuracy and eye movements during visual change detection tasks with different degrees of attentional filtering and allocation requirements. Our results did not indicate strong filtering differences between high- and low-WMC groups, and where differences were observed, they were counter to those predicted by the strongest attentional filtering hypothesis. Bayes factors indicated evidence favoring positive or null relationships between WMC and correct responses to unemphasized information, as well as between WMC and the time spent looking at unemphasized information. These findings are consistent with the hypothesis that individual differences in storage capacity, not only filtering efficiency, underlie individual differences in working memory.

  6. High Spectral Resolution Infrared and Raman Lidar Observations for the ARM Program: Clear and Cloudy Sky Applications

    Energy Technology Data Exchange (ETDEWEB)

    Revercomb, Henry; Tobin, David; Knuteson, Robert; Borg, Lori; Moy, Leslie

    2009-06-17

    This grant began with the development of the Atmospheric Emitted Radiance Interferometer (AERI) for ARM. The AERI has provided highly accurate and reliable observations of downwelling spectral radiance (Knuteson et al. 2004a, 2004b) for application to radiative transfer, remote sensing of boundary layer temperature and water vapor, and cloud characterization. One of the major contributions of the ARM program has been its success in improving radiation calculation capabilities for models and remote sensing that evolved from the multi-year, clear-sky spectral radiance comparisons between AERI radiances and line-by-line calculations (Turner et al. 2004). This effort also spurred us to play a central role in improving the accuracy of water vapor measurements, again helping ARM lead the way in the community (Turner et al. 2003a, Revercomb et al. 2003). In order to add high-altitude downlooking AERI-like observations over the ARM sites, we began the development of an airborne AERI instrument that has become known as the Scanning High-resolution Interferometer Sounder (Scanning-HIS). This instrument has become an integral part of the ARM Unmanned Aerospace Vehicle (ARM-UAV) program. It provides both a cross-track mapping view of the earth and an uplooking view from the 12-15 km altitude of the Scaled Composites Proteus aircraft when flown over the ARM sites for IOPs. It has successfully participated in the first two legs of the “grand tour” of the ARM sites (SGP and NSA), resulting in a very good comparison with AIRS observations in 2002 and in an especially interesting data set from the arctic during the Mixed-Phase Cloud Experiment (M-PACE) in 2004.

  7. Improvement of Gaofen-3 Absolute Positioning Accuracy Based on Cross-Calibration

    Directory of Open Access Journals (Sweden)

    Mingjun Deng

    2017-12-01

    Full Text Available The Chinese Gaofen-3 (GF-3 mission was launched in August 2016, equipped with a full polarimetric synthetic aperture radar (SAR sensor in the C-band, with a resolution of up to 1 m. The absolute positioning accuracy of GF-3 is of great importance, and in-orbit geometric calibration is a key technology for improving absolute positioning accuracy. Conventional geometric calibration is used to accurately calibrate the geometric calibration parameters of the image (internal delay and azimuth shifts using high-precision ground control data, which are highly dependent on the control data of the calibration field, but it remains costly and labor-intensive to monitor changes in GF-3’s geometric calibration parameters. Based on the positioning consistency constraint of the conjugate points, this study presents a geometric cross-calibration method for the rapid and accurate calibration of GF-3. The proposed method can accurately calibrate geometric calibration parameters without using corner reflectors and high-precision digital elevation models, thus improving absolute positioning accuracy of the GF-3 image. GF-3 images from multiple regions were collected to verify the absolute positioning accuracy after cross-calibration. The results show that this method can achieve a calibration accuracy as high as that achieved by the conventional field calibration method.

  8. THE ACCURACY OF Hβ CCD PHOTOMETRY

    Directory of Open Access Journals (Sweden)

    C. Kim

    1994-12-01

    Full Text Available We have undertaken CCD observations of field standard stars with Hβ photometric system to investigate the reliability of Hβ CCD photometry. Flat fielding with dome flat and sky flat for Hβw and Hβn filter was compared with that of B filter in UBV system and, from these, we have not found any difference. It was confirmed that there is a good linear relationship between our Hβ values observed with 2.3m reflector and standard values. However, Hβ values observed with 60cm reflector at Sobaeksan Astronomy Observatory showed very poor relationship. To investigate the accuracy of Hβ CCD photometry for fainter objects, open cluster NGC2437 was observed and reduced with DoPHOT, and the results were compared with those for photoelectric photometry of Stetson (1981.

  9. Sequential Monte Carlo with Highly Informative Observations

    OpenAIRE

    Del Moral, Pierre; Murray, Lawrence M.

    2014-01-01

    We propose sequential Monte Carlo (SMC) methods for sampling the posterior distribution of state-space models under highly informative observation regimes, a situation in which standard SMC methods can perform poorly. A special case is simulating bridges between given initial and final values. The basic idea is to introduce a schedule of intermediate weighting and resampling times between observation times, which guide particles towards the final state. This can always be done for continuous-...

  10. Accuracy of the initial diagnosis among patients with an acutely altered mental status

    OpenAIRE

    Sporer, KA; Solares, M; Edward, JD; Wang, W; Alan, HBW; Robert, MR

    2013-01-01

    Objectives: The objectives of this prospective observational study were to: (1) determine the accuracy of physician diagnosis in patients with an acutely altered mental status (AMS) within the first 20 min of emergency department (ED) presentation; and (2) access if physician confidence in early diagnosis correlates with accuracy of diagnosis. Methods: A prospective observational convenience study was conducted of 112 adult patients who presented to an urban county ED with AMS (Glasgow Coma S...

  11. Persistence of accuracy of genomic estimated breeding values over generations in layer chickens

    Directory of Open Access Journals (Sweden)

    Fernando Rohan

    2011-06-01

    Full Text Available Abstract Background The predictive ability of genomic estimated breeding values (GEBV originates both from associations between high-density markers and QTL (Quantitative Trait Loci and from pedigree information. Thus, GEBV are expected to provide more persistent accuracy over successive generations than breeding values estimated using pedigree-based methods. The objective of this study was to evaluate the accuracy of GEBV in a closed population of layer chickens and to quantify their persistence over five successive generations using marker or pedigree information. Methods The training data consisted of 16 traits and 777 genotyped animals from two generations of a brown-egg layer breeding line, 295 of which had individual phenotype records, while others had phenotypes on 2,738 non-genotyped relatives, or similar data accumulated over up to five generations. Validation data included phenotyped and genotyped birds from five subsequent generations (on average 306 birds/generation. Birds were genotyped for 23,356 segregating SNP. Animal models using genomic or pedigree relationship matrices and Bayesian model averaging methods were used for training analyses. Accuracy was evaluated as the correlation between EBV and phenotype in validation divided by the square root of trait heritability. Results Pedigree relationships in outbred populations are reduced by 50% at each meiosis, therefore accuracy is expected to decrease by the square root of 0.5 every generation, as observed for pedigree-based EBV (Estimated Breeding Values. In contrast the GEBV accuracy was more persistent, although the drop in accuracy was substantial in the first generation. Traits that were considered to be influenced by fewer QTL and to have a higher heritability maintained a higher GEBV accuracy over generations. In conclusion, GEBV capture information beyond pedigree relationships, but retraining every generation is recommended for genomic selection in closed breeding

  12. Accuracy and inter-observer variability of 3D versus 4D cone-beam CT based image-guidance in SBRT for lung tumors

    International Nuclear Information System (INIS)

    Sweeney, Reinhart A; Seubert, Benedikt; Stark, Silke; Homann, Vanessa; Müller, Gerd; Flentje, Michael; Guckenberger, Matthias

    2012-01-01

    To analyze the accuracy and inter-observer variability of image-guidance (IG) using 3D or 4D cone-beam CT (CBCT) technology in stereotactic body radiotherapy (SBRT) for lung tumors. Twenty-one consecutive patients treated with image-guided SBRT for primary and secondary lung tumors were basis for this study. A respiration correlated 4D-CT and planning contours served as reference for all IG techniques. Three IG techniques were performed independently by three radiation oncologists (ROs) and three radiotherapy technicians (RTTs). Image-guidance using respiration correlated 4D-CBCT (IG-4D) with automatic registration of the planning 4D-CT and the verification 4D-CBCT was considered gold-standard. Results were compared with two IG techniques using 3D-CBCT: 1) manual registration of the planning internal target volume (ITV) contour and the motion blurred tumor in the 3D-CBCT (IG-ITV); 2) automatic registration of the planning reference CT image and the verification 3D-CBCT (IG-3D). Image quality of 3D-CBCT and 4D-CBCT images was scored on a scale of 1–3, with 1 being best and 3 being worst quality for visual verification of the IGRT results. Image quality was scored significantly worse for 3D-CBCT compared to 4D-CBCT: the worst score of 3 was given in 19 % and 7.1 % observations, respectively. Significant differences in target localization were observed between 4D-CBCT and 3D-CBCT based IG: compared to the reference of IG-4D, tumor positions differed by 1.9 mm ± 0.9 mm (3D vector) on average using IG-ITV and by 3.6 mm ± 3.2 mm using IG-3D; results of IG-ITV were significantly closer to the reference IG-4D compared to IG-3D. Differences between the 4D-CBCT and 3D-CBCT techniques increased significantly with larger motion amplitude of the tumor; analogously, differences increased with worse 3D-CBCT image quality scores. Inter-observer variability was largest in SI direction and was significantly larger in IG using 3D-CBCT compared to 4D-CBCT: 0.6 mm versus 1.5 mm

  13. Accuracy and inter-observer variability of 3D versus 4D cone-beam CT based image-guidance in SBRT for lung tumors

    Directory of Open Access Journals (Sweden)

    Sweeney Reinhart A

    2012-06-01

    Full Text Available Abstract Background To analyze the accuracy and inter-observer variability of image-guidance (IG using 3D or 4D cone-beam CT (CBCT technology in stereotactic body radiotherapy (SBRT for lung tumors. Materials and methods Twenty-one consecutive patients treated with image-guided SBRT for primary and secondary lung tumors were basis for this study. A respiration correlated 4D-CT and planning contours served as reference for all IG techniques. Three IG techniques were performed independently by three radiation oncologists (ROs and three radiotherapy technicians (RTTs. Image-guidance using respiration correlated 4D-CBCT (IG-4D with automatic registration of the planning 4D-CT and the verification 4D-CBCT was considered gold-standard. Results were compared with two IG techniques using 3D-CBCT: 1 manual registration of the planning internal target volume (ITV contour and the motion blurred tumor in the 3D-CBCT (IG-ITV; 2 automatic registration of the planning reference CT image and the verification 3D-CBCT (IG-3D. Image quality of 3D-CBCT and 4D-CBCT images was scored on a scale of 1–3, with 1 being best and 3 being worst quality for visual verification of the IGRT results. Results Image quality was scored significantly worse for 3D-CBCT compared to 4D-CBCT: the worst score of 3 was given in 19 % and 7.1 % observations, respectively. Significant differences in target localization were observed between 4D-CBCT and 3D-CBCT based IG: compared to the reference of IG-4D, tumor positions differed by 1.9 mm ± 0.9 mm (3D vector on average using IG-ITV and by 3.6 mm ± 3.2 mm using IG-3D; results of IG-ITV were significantly closer to the reference IG-4D compared to IG-3D. Differences between the 4D-CBCT and 3D-CBCT techniques increased significantly with larger motion amplitude of the tumor; analogously, differences increased with worse 3D-CBCT image quality scores. Inter-observer variability was largest in SI direction and was

  14. Evaluating Behavioral Self-Monitoring with Accuracy Training for Changing Computer Work Postures

    Science.gov (United States)

    Gravina, Nicole E.; Loewy, Shannon; Rice, Anna; Austin, John

    2013-01-01

    The primary purpose of this study was to replicate and extend a study by Gravina, Austin, Schroedter, and Loewy (2008). A similar self-monitoring procedure, with the addition of self-monitoring accuracy training, was implemented to increase the percentage of observations in which participants worked in neutral postures. The accuracy training…

  15. Affine-Invariant Geometric Constraints-Based High Accuracy Simultaneous Localization and Mapping

    Directory of Open Access Journals (Sweden)

    Gangchen Hua

    2017-01-01

    Full Text Available In this study we describe a new appearance-based loop-closure detection method for online incremental simultaneous localization and mapping (SLAM using affine-invariant-based geometric constraints. Unlike other pure bag-of-words-based approaches, our proposed method uses geometric constraints as a supplement to improve accuracy. By establishing an affine-invariant hypothesis, the proposed method excludes incorrect visual words and calculates the dispersion of correctly matched visual words to improve the accuracy of the likelihood calculation. In addition, camera’s intrinsic parameters and distortion coefficients are adequate for this method. 3D measuring is not necessary. We use the mechanism of Long-Term Memory and Working Memory (WM to manage the memory. Only a limited size of the WM is used for loop-closure detection; therefore the proposed method is suitable for large-scale real-time SLAM. We tested our method using the CityCenter and Lip6Indoor datasets. Our proposed method results can effectively correct the typical false-positive localization of previous methods, thus gaining better recall ratios and better precision.

  16. A high-accuracy extraction of the isoscalar πN scattering length from pionic deuterium data

    International Nuclear Information System (INIS)

    Phillips, Daniel R.; Baru, Vadim; Hanhart, Christoph; Nogga, Andreas; Hoferichter, Martin; Kubis, Bastian

    2010-01-01

    We present a high-accuracy calculation of the π(bar sign)d scattering length using chiral perturbation theory up to order (M π /m p ) 7/2 . For the first time isospin-violating corrections are included consistently. The resulting value of a π -bar d has a theoretical uncertainty of a few percent. We use it, together with data on pionic deuterium and pionic hydrogen atoms, to extract the isoscalar and isovector pion-nucleon scattering lengths from a combined analysis, and obtain a + (7.9±3.2)·10 -3 M π -1 and a-bar (86.3±1.0)·10 -3 M π -1 .

  17. Age-related differences in the accuracy of web query-based predictions of influenza-like illness.

    Directory of Open Access Journals (Sweden)

    Alexander Domnich

    Full Text Available Web queries are now widely used for modeling, nowcasting and forecasting influenza-like illness (ILI. However, given that ILI attack rates vary significantly across ages, in terms of both magnitude and timing, little is known about whether the association between ILI morbidity and ILI-related queries is comparable across different age-groups. The present study aimed to investigate features of the association between ILI morbidity and ILI-related query volume from the perspective of age.Since Google Flu Trends is unavailable in Italy, Google Trends was used to identify entry terms that correlated highly with official ILI surveillance data. All-age and age-class-specific modeling was performed by means of linear models with generalized least-square estimation. Hold-out validation was used to quantify prediction accuracy. For purposes of comparison, predictions generated by exponential smoothing were computed.Five search terms showed high correlation coefficients of > .6. In comparison with exponential smoothing, the all-age query-based model correctly predicted the peak time and yielded a higher correlation coefficient with observed ILI morbidity (.978 vs. .929. However, query-based prediction of ILI morbidity was associated with a greater error. Age-class-specific query-based models varied significantly in terms of prediction accuracy. In the 0-4 and 25-44-year age-groups, these did well and outperformed exponential smoothing predictions; in the 15-24 and ≥ 65-year age-classes, however, the query-based models were inaccurate and highly overestimated peak height. In all but one age-class, peak timing predicted by the query-based models coincided with observed timing.The accuracy of web query-based models in predicting ILI morbidity rates could differ among ages. Greater age-specific detail may be useful in flu query-based studies in order to account for age-specific features of the epidemiology of ILI.

  18. Accuracy of ab initio electron correlation and electron densities in vanadium dioxide

    Science.gov (United States)

    Kylänpää, Ilkka; Balachandran, Janakiraman; Ganesh, Panchapakesan; Heinonen, Olle; Kent, Paul R. C.; Krogel, Jaron T.

    2017-11-01

    Diffusion quantum Monte Carlo results are used as a reference to analyze properties related to phase stability and magnetism in vanadium dioxide computed with various formulations of density functional theory. We introduce metrics related to energetics, electron densities and spin densities that give us insight on both local and global variations in the antiferromagnetic M1 and R phases. Importantly, these metrics can address contributions arising from the challenging description of the 3 d orbital physics in this material. We observe that the best description of energetics between the structural phases does not correspond to the best accuracy in the charge density, which is consistent with observations made recently by Medvedev et al. [Science 355, 371 (2017), 10.1126/science.aag0410] in the context of isolated atoms. However, we do find evidence that an accurate spin density connects to correct energetic ordering of different magnetic states in VO2, although local, semilocal, and meta-GGA functionals tend to erroneously favor demagnetization of the vanadium sites. The recently developed SCAN functional stands out as remaining nearly balanced in terms of magnetization across the M1-R transition and correctly predicting the ground state crystal structure. In addition to ranking current density functionals, our reference energies and densities serve as important benchmarks for future functional development. With our reference data, the accuracy of both the energy and the electron density can be monitored simultaneously, which is useful for functional development. So far, this kind of detailed high accuracy reference data for correlated materials has been absent from the literature.

  19. Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with high-grade glioma, a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dijken, Bart R.J. van [University of Groningen, University Medical Center Groningen Department of Radiology, Groningen (Netherlands); Laar, Peter Jan van; Hoorn, Anouk van der [University of Groningen, University Medical Center Groningen Department of Radiology, Groningen (Netherlands); University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Holtman, Gea A. [University of Groningen, University Medical Center Groningen, Department of General Practice, Groningen (Netherlands)

    2017-10-15

    Treatment response assessment in high-grade gliomas uses contrast enhanced T1-weighted MRI, but is unreliable. Novel advanced MRI techniques have been studied, but the accuracy is not well known. Therefore, we performed a systematic meta-analysis to assess the diagnostic accuracy of anatomical and advanced MRI for treatment response in high-grade gliomas. Databases were searched systematically. Study selection and data extraction were done by two authors independently. Meta-analysis was performed using a bivariate random effects model when ≥5 studies were included. Anatomical MRI (five studies, 166 patients) showed a pooled sensitivity and specificity of 68% (95%CI 51-81) and 77% (45-93), respectively. Pooled apparent diffusion coefficients (seven studies, 204 patients) demonstrated a sensitivity of 71% (60-80) and specificity of 87% (77-93). DSC-perfusion (18 studies, 708 patients) sensitivity was 87% (82-91) with a specificity of 86% (77-91). DCE-perfusion (five studies, 207 patients) sensitivity was 92% (73-98) and specificity was 85% (76-92). The sensitivity of spectroscopy (nine studies, 203 patients) was 91% (79-97) and specificity was 95% (65-99). Advanced techniques showed higher diagnostic accuracy than anatomical MRI, the highest for spectroscopy, supporting the use in treatment response assessment in high-grade gliomas. (orig.)

  20. Accuracy and repeatability of quantitative fluoroscopy for the measurement of sagittal plane translation and finite centre of rotation in the lumbar spine.

    Science.gov (United States)

    Breen, Alexander; Breen, Alan

    2016-07-01

    Quantitative fluoroscopy (QF) was developed to measure intervertebral mechanics in vivo and has been found to have high repeatability and accuracy for the measurement of intervertebral rotations. However, sagittal plane translation and finite centre of rotation (FCR) are potential measures of stability but have not yet been fully validated for current QF. This study investigated the repeatability and accuracy of QF for measuring these variables. Repeatability was assessed from L2-S1 in 20 human volunteers. Accuracy was investigated using 10 consecutive measurements from each of two pairs of linked and instrumented dry human vertebrae as reference; one which tilted without translation and one which translated without tilt. The results found intra- and inter-observer repeatability for translation to be 1.1mm or less (SEM) with fair to substantial reliability (ICC 0.533-0.998). Intra-observer repeatability of FCR location for inter-vertebral rotations of 5° and above ranged from 1.5mm to 1.8mm (SEM) with moderate to substantial reliability (ICC 0.626-0.988). Inter-observer repeatability for FCR ranged from 1.2mm to 5.7mm, also with moderate to substantial reliability (ICC 0.621-0.878). Reliability was substantial (ICC>0.81) for 10/16 measures for translation and 5/8 for FCR location. Accuracy for translation was 0.1mm (fixed centre) and 2.2mm (moveable centre), with an FCR error of 0.3mm(x) and 0.4mm(y) (fixed centre). This technology was found to have a high level of accuracy and with a few exceptions, moderate to substantial repeatability for the measurement of translation and FCR from fluoroscopic motion sequences. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  1. Accuracy assessment of airborne laser scanning strips using planar features

    NARCIS (Netherlands)

    Soudarissanane, S.S.; Van der Sande, C.J.; Khoshelham, K.

    2010-01-01

    Airborne Laser Scanning (ALS) is widely used in many applications for its high measurement accuracy, fast acquisition capability, and large spatial coverage. Accuracy assessment of the ALS data usually relies on comparing corresponding tie elements, often points or lines, in the overlapping strips.

  2. Accuracy of clinical pallor in the diagnosis of anaemia in children: a meta-analysis

    Science.gov (United States)

    Chalco, Juan P; Huicho, Luis; Alamo, Carlos; Carreazo, Nilton Y; Bada, Carlos A

    2005-01-01

    Background Anaemia is highly prevalent in children of developing countries. It is associated with impaired physical growth and mental development. Palmar pallor is recommended at primary level for diagnosing it, on the basis of few studies. The objective of the study was to systematically assess the accuracy of clinical signs in the diagnosis of anaemia in children. Methods A systematic review on the accuracy of clinical signs of anaemia in children. We performed an Internet search in various databases and an additional reference tracking. Studies had to be on performance of clinical signs in the diagnosis of anaemia, using haemoglobin as the gold standard. We calculated pooled diagnostic likelihood ratios (LR's) and odds ratios (DOR's) for each clinical sign at different haemoglobin thresholds. Results Eleven articles met the inclusion criteria. Most studies were performed in Africa, in children underfive. Chi-square test for proportions and Cochran Q for DOR's and for LR's showed heterogeneity. Type of observer and haemoglobin technique influenced the results. Pooling was done using the random effects model. Pooled DOR at haemoglobin outliers. Conclusion This meta-analysis did not document a highly accurate clinical sign of anaemia. In view of poor performance of clinical signs, universal iron supplementation may be an adequate control strategy in high prevalence areas. Further well-designed studies are needed in settings other than Africa. They should assess inter-observer variation, performance of combined clinical signs, phenotypic differences, and different degrees of anaemia. PMID:16336667

  3. Improving decision speed, accuracy and group cohesion through early information gathering in house-hunting ants.

    Directory of Open Access Journals (Sweden)

    Nathalie Stroeymeyt

    Full Text Available BACKGROUND: Successful collective decision-making depends on groups of animals being able to make accurate choices while maintaining group cohesion. However, increasing accuracy and/or cohesion usually decreases decision speed and vice-versa. Such trade-offs are widespread in animal decision-making and result in various decision-making strategies that emphasize either speed or accuracy, depending on the context. Speed-accuracy trade-offs have been the object of many theoretical investigations, but these studies did not consider the possible effects of previous experience and/or knowledge of individuals on such trade-offs. In this study, we investigated how previous knowledge of their environment may affect emigration speed, nest choice and colony cohesion in emigrations of the house-hunting ant Temnothorax albipennis, a collective decision-making process subject to a classical speed-accuracy trade-off. METHODOLOGY/PRINCIPAL FINDINGS: Colonies allowed to explore a high quality nest site for one week before they were forced to emigrate found that nest and accepted it faster than emigrating naïve colonies. This resulted in increased speed in single choice emigrations and higher colony cohesion in binary choice emigrations. Additionally, colonies allowed to explore both high and low quality nest sites for one week prior to emigration remained more cohesive, made more accurate decisions and emigrated faster than emigrating naïve colonies. CONCLUSIONS/SIGNIFICANCE: These results show that colonies gather and store information about available nest sites while their nest is still intact, and later retrieve and use this information when they need to emigrate. This improves colony performance. Early gathering of information for later use is therefore an effective strategy allowing T. albipennis colonies to improve simultaneously all aspects of the decision-making process--i.e. speed, accuracy and cohesion--and partly circumvent the speed-accuracy trade

  4. High PT electronuclear reactions and spin observables

    International Nuclear Information System (INIS)

    Laget, J.M.

    1990-01-01

    The main arguments of the following topics are reviewed: the high transverse momentum exclusive reactions, the determination of various spin observables and the production of different flavours in reactions induced by real and virtual photons

  5. High accuracy navigation information estimation for inertial system using the multi-model EKF fusing adams explicit formula applied to underwater gliders.

    Science.gov (United States)

    Huang, Haoqian; Chen, Xiyuan; Zhang, Bo; Wang, Jian

    2017-01-01

    The underwater navigation system, mainly consisting of MEMS inertial sensors, is a key technology for the wide application of underwater gliders and plays an important role in achieving high accuracy navigation and positioning for a long time of period. However, the navigation errors will accumulate over time because of the inherent errors of inertial sensors, especially for MEMS grade IMU (Inertial Measurement Unit) generally used in gliders. The dead reckoning module is added to compensate the errors. In the complicated underwater environment, the performance of MEMS sensors is degraded sharply and the errors will become much larger. It is difficult to establish the accurate and fixed error model for the inertial sensor. Therefore, it is very hard to improve the accuracy of navigation information calculated by sensors. In order to solve the problem mentioned, the more suitable filter which integrates the multi-model method with an EKF approach can be designed according to different error models to give the optimal estimation for the state. The key parameters of error models can be used to determine the corresponding filter. The Adams explicit formula which has an advantage of high precision prediction is simultaneously fused into the above filter to achieve the much more improvement in attitudes estimation accuracy. The proposed algorithm has been proved through theory analyses and has been tested by both vehicle experiments and lake trials. Results show that the proposed method has better accuracy and effectiveness in terms of attitudes estimation compared with other methods mentioned in the paper for inertial navigation applied to underwater gliders. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  6. Near Infrared High Resolution Spectroscopy and Spectro-astrometry of Gas in Disks around Herbig Ae/Be Stars

    OpenAIRE

    Brittain, Sean D.; Najita, Joan R.; Carr, John S.

    2015-01-01

    In this review, we describe how high resolution near infrared spectroscopy and spectro-astrometry have been used to study the disks around Herbig~Ae/Be stars. We show how these tools can be used to identify signposts of planet formation and elucidate the mechanism by which Herbig Ae/Be stars accrete. We also highlight some of the artifacts that can complicate the interpretation of spectro-astrometric measurements and discuss best practices for mitigating these effects. We conclude with a brie...

  7. High accuracy results for the energy levels of the molecular ions H+2, D+2 and HD+, up to J = 2

    International Nuclear Information System (INIS)

    Karr, J Ph; Hilico, L

    2006-01-01

    We present a nonrelativistic calculation of the rotation-vibration levels of the molecular ions H + 2 , D + 2 and HD + , relying on the diagonalization of the exact three-body Hamiltonian in a variational basis. The J = 2 levels are obtained with a very high accuracy of 10 -14 au (for most levels) representing an improvement by five orders of magnitude over previous calculations. The accuracy is also improved for the J = 1 levels of H + 2 and D + 2 with respect to earlier works. Moreover, we have computed the sensitivities of the energy levels with respect to the mass ratios, allowing these levels to be used for metrological purposes

  8. Ultra-wideband ranging precision and accuracy

    International Nuclear Information System (INIS)

    MacGougan, Glenn; O'Keefe, Kyle; Klukas, Richard

    2009-01-01

    This paper provides an overview of ultra-wideband (UWB) in the context of ranging applications and assesses the precision and accuracy of UWB ranging from both a theoretical perspective and a practical perspective using real data. The paper begins with a brief history of UWB technology and the most current definition of what constitutes an UWB signal. The potential precision of UWB ranging is assessed using Cramer–Rao lower bound analysis. UWB ranging methods are described and potential error sources are discussed. Two types of commercially available UWB ranging radios are introduced which are used in testing. Actual ranging accuracy is assessed from line-of-sight testing under benign signal conditions by comparison to high-accuracy electronic distance measurements and to ranges derived from GPS real-time kinematic positioning. Range measurements obtained in outdoor testing with line-of-sight obstructions and strong reflection sources are compared to ranges derived from classically surveyed positions. The paper concludes with a discussion of the potential applications for UWB ranging

  9. High-accuracy interferometric measurements of flatness and parallelism of a step gauge

    CSIR Research Space (South Africa)

    Kruger, OA

    2001-01-01

    Full Text Available The most commonly used method in the calibration of step gauges is the coordinate measuring machine (CMM), equipped with a laser interferometer for the highest accuracy. This paper describes a modification to a length-bar measuring machine...

  10. Studies of relativistic effects with radioastron space mission

    Directory of Open Access Journals (Sweden)

    Zakharov A.F.

    2007-01-01

    Full Text Available In the review we discuss possible studies of GR phenomena such as gravitational microlensing and shadow analysis with the forthcoming RadioAstron space mission. It is well-known that gravitational lensing is a powerful tool in the investigation of the distribution of matter, including that of dark matter (DM. Typical angular distances between images and typical time scales depend on the gravitational lens masses. For the microlensing, angular distances between images or typical astrometric shifts are about 10-5 – 10-6 as1. Such an angular resolution will be reached with the space-ground VLBI interferometer, Radioastron. The basic targets for microlensing searches should be bright point-like radio sources at cosmological distances. In this case, an analysis of their variability and a reliable determination of microlensing could lead to an estimation of their cosmological mass density. Moreover, one could not exclude the possibility that non-baryonic dark matter could also form microlenses if the corresponding optical depth were high enough. It is known that in gravitationally lensed systems, the probability (the optical depth to observe microlensing is relatively high; therefore, for example, such gravitationally lensed objects, like CLASS gravitational lens B1600+434, appear the most suitable to detect astrometric microlensing, since features of photometric microlensing have been detected in these objects. However, to directly resolve these images and to directly detect the apparent motion of the knots, the Radioastron sensitivity would have to be improved, since the estimated flux density is below the sensitivity threshold, alternatively, they may be observed by increasing the integration time, assuming that a radio source has a typical core - jet structure and microlensing phenomena are caused by the superluminal apparent motions of knots. In the case of a confirmation (or a disproval of claims about microlensing in grav­itational lens

  11. Effects of appraisal purpose and rating format on performance appraisal accuracy

    OpenAIRE

    Carter, Marta L.

    1989-01-01

    The principle of encoding specificity states that effective information retrieval relies upon consistency of encoding and retrieval cues. The present study generalized this principle to a complex social interaction in order to investigate the relation between certain combinations of pre- and post-observational cues and their effects on information categorization, recognition accuracy, and judgment accuracy. It was hypothesized that two experimental factors, appraisal pur...

  12. A diabetes dashboard and physician efficiency and accuracy in accessing data needed for high-quality diabetes care.

    Science.gov (United States)

    Koopman, Richelle J; Kochendorfer, Karl M; Moore, Joi L; Mehr, David R; Wakefield, Douglas S; Yadamsuren, Borchuluun; Coberly, Jared S; Kruse, Robin L; Wakefield, Bonnie J; Belden, Jeffery L

    2011-01-01

    We compared use of a new diabetes dashboard screen with use of a conventional approach of viewing multiple electronic health record (EHR) screens to find data needed for ambulatory diabetes care. We performed a usability study, including a quantitative time study and qualitative analysis of information-seeking behaviors. While being recorded with Morae Recorder software and "think-aloud" interview methods, 10 primary care physicians first searched their EHR for 10 diabetes data elements using a conventional approach for a simulated patient, and then using a new diabetes dashboard for another. We measured time, number of mouse clicks, and accuracy. Two coders analyzed think-aloud and interview data using grounded theory methodology. The mean time needed to find all data elements was 5.5 minutes using the conventional approach vs 1.3 minutes using the diabetes dashboard (P dashboard (P dashboard (P dashboard improves both the efficiency and accuracy of acquiring data needed for high-quality diabetes care. Usability analysis tools can provide important insights into the value of optimizing physician use of health information technologies.

  13. High contrast stellar observations within the diffraction limit at the Palomar Hale telescope

    Science.gov (United States)

    Mennesson, B.; Hanot, C.; Serabyn, E.; Martin, S. R.; Liewer, K.; Loya, F.; Mawet, D.

    2010-07-01

    We report on high-accuracy, high-resolution (statistical method, baptized "Null Self-Calibration" (NSC), which provides astrophysical null measurements at the 0.001 level, with 1 σ uncertainties as low as 0.0003. Such accuracy translates into a dynamic range greater than 1000:1 within the diffraction limit, demonstrating that the approach effectively bridges the traditional gap between regular coronagraphs, limited in angular resolution, and long baseline visibility interferometers, whose dynamic range is restricted to 100:1. As our measurements are extremely sensitive to the brightness distribution very close to the optical axis, we were able to constrain the stellar diameters and amounts of circumstellar emission for a sample of very bright stars. With the improvement expected when the PALM-3000 extreme AO system comes on-line at Palomar, the same instrument now equipped with a state of the art low noise fast read-out near IR camera, will yield 10-4 to 10-3 contrast as close as 30 mas for stars with K magnitude brighter than 6. Such a system will provide a unique and ideal tool for the detection of young (AUs) of nearby (< 50pc) stars.

  14. The Mass of the Candidate Exoplanet Companion to HD 33636 from Hubble Space Telescope Astrometry and High-Precision Radial Velocities

    Science.gov (United States)

    Bean, Jacob L.; McArthur, Barbara E.; Benedict, G. Fritz; Harrison, Thomas E.; Bizyaev, Dmitry; Nelan, Edmund; Smith, Verne V.

    2007-08-01

    We have determined a dynamical mass for the companion to HD 33636 that indicates it is a low-mass star instead of an exoplanet. Our result is based on an analysis of Hubble Space Telescope (HST) astrometry and ground-based radial velocity data. We have obtained high-cadence radial velocity measurements spanning 1.3 yr of HD 33636 with the Hobby-Eberly Telescope at McDonald Observatory. We combined these data with previously published velocities to create a data set that spans 9 yr. We used this data set to search for, and place mass limits on, the existence of additional companions in the HD 33636 system. Our high-precision astrometric observations of the system with the HST Fine Guidance Sensor 1r span 1.2 yr. We simultaneously modeled the radial velocity and astrometry data to determine the parallax, proper motion, and perturbation orbit parameters of HD 33636. Our derived parallax, πabs=35.6+/-0.2 mas, agrees within the uncertainties with the Hipparcos value. We find a perturbation period P=2117.3+/-0.8 days, semimajor axis aA=14.2+/-0.2 mas, and system inclination i=4.1deg+/-0.1deg. Assuming the mass of the primary star to be MA=1.02+/-0.03 Msolar, we obtain a companion mass MB=142+/-11 MJup=0.14+/-0.01 Msolar. The much larger true mass of the companion relative to its minimum mass estimated from the spectroscopic orbit parameters (Msini=9.3 MJup) is due to the nearly face-on orbit orientation. This result demonstrates the value of follow-up astrometric observations to determine the true masses of exoplanet candidates detected with the radial velocity method. Based on data obtained with the NASA/ESA Hubble Space Telescope (HST) and the Hobby-Eberly Telescope (HET). The HST observations were obtained at the Space Telescope Science Institute, which is operated by the Association of Universities for Research in Astronomy, Inc., under NASA contract NAS5-26555. The HET is a joint project of the University of Texas at Austin, Pennsylvania State University, Stanford

  15. Magnetic resonance arthrography including ABER view in diagnosing partial-thickness tears of the rotator cuff: Accuracy, and inter- and intra-observer agreements

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joon-Yong; Jee, Won-Hee; Chun, Ho Jong; Ahn, Myeong Im (Dept. of Radiology, Seoul St. Mary' s Hospital, School of Medicine, Catholic Univ. of Korea, Seoul (Korea)), e-mail: whjee@catholic.ac.kr; Kim, Yang-Soo (Dept. of Orthopedic Surgery, Seoul St. Mary' s Hospital, School of Medicine, Catholic Univ. of Korea, Seoul (Korea))

    2010-03-15

    Background: Partial-thickness tear of the rotator cuff is a common cause of shoulder pain. Magnetic resonance (MR) arthrography has been described as a useful measure to diagnose rotator cuff abnormalities. Purpose: To determine the reliability and accuracy of MR arthrography with abduction and external rotation (ABER) view for the diagnosis of partial-thickness tears of the rotator cuff. Material and Methods: Among patients who underwent MR arthrographies, 22 patients (12 men, 10 women; mean age 45 years) who had either partial-thickness tear or normal tendon on arthroscopy were included. MR images were independently scored by two observers for partial-thickness tears of the rotator cuff. Interobserver and intraobserver agreements for detection of partial-thickness tears of the rotator cuff were calculated by using kappa coefficients. The differences in areas under the receiver operating characteristic (ROC) curves were assessed with a univariate Z-score test. Differences in sensitivity and specificity for interpretations based on different imaging series were tested for significance using the McNemar statistic. Results: Sensitivity, specificity, and accuracy of each reader on MR imaging without ABER view were 83%, 90%, and 86%, and 83%, 80%, and 82%, respectively, whereas on overall interpretation including ABER view, the sensitivity, specificity, and accuracy of each reader were 92%, 70%, and 82%, and 92%, 80%, and 86%, respectively. Including ABER view, interobserver agreement for partial-thickness tear increased from kappa=0.55 to kappa=0.68. Likewise, intraobserver agreements increased from kappa=0.79 and 0.53 to kappa=0.81 and 0.70 for each reader, respectively. The areas under the ROC curves for each reader were 0.96 and 0.90, which were not significantly different. Conclusion: Including ABER view in routine sequences of MR arthrography increases the sensitivity, and inter- and intraobserver agreements for detecting partial-thickness tear of rotator cuff

  16. Magnetic resonance arthrography including ABER view in diagnosing partial-thickness tears of the rotator cuff: Accuracy, and inter- and intra-observer agreements

    International Nuclear Information System (INIS)

    Jung, Joon-Yong; Jee, Won-Hee; Chun, Ho Jong; Ahn, Myeong Im; Kim, Yang-Soo

    2010-01-01

    Background: Partial-thickness tear of the rotator cuff is a common cause of shoulder pain. Magnetic resonance (MR) arthrography has been described as a useful measure to diagnose rotator cuff abnormalities. Purpose: To determine the reliability and accuracy of MR arthrography with abduction and external rotation (ABER) view for the diagnosis of partial-thickness tears of the rotator cuff. Material and Methods: Among patients who underwent MR arthrographies, 22 patients (12 men, 10 women; mean age 45 years) who had either partial-thickness tear or normal tendon on arthroscopy were included. MR images were independently scored by two observers for partial-thickness tears of the rotator cuff. Interobserver and intraobserver agreements for detection of partial-thickness tears of the rotator cuff were calculated by using κ coefficients. The differences in areas under the receiver operating characteristic (ROC) curves were assessed with a univariate Z-score test. Differences in sensitivity and specificity for interpretations based on different imaging series were tested for significance using the McNemar statistic. Results: Sensitivity, specificity, and accuracy of each reader on MR imaging without ABER view were 83%, 90%, and 86%, and 83%, 80%, and 82%, respectively, whereas on overall interpretation including ABER view, the sensitivity, specificity, and accuracy of each reader were 92%, 70%, and 82%, and 92%, 80%, and 86%, respectively. Including ABER view, interobserver agreement for partial-thickness tear increased from κ=0.55 to κ=0.68. Likewise, intraobserver agreements increased from κ=0.79 and 0.53 to κ=0.81 and 0.70 for each reader, respectively. The areas under the ROC curves for each reader were 0.96 and 0.90, which were not significantly different. Conclusion: Including ABER view in routine sequences of MR arthrography increases the sensitivity, and inter- and intraobserver agreements for detecting partial-thickness tear of rotator cuff tendon

  17. Analysis of RDSS positioning accuracy based on RNSS wide area differential technique

    Science.gov (United States)

    Xing, Nan; Su, RanRan; Zhou, JianHua; Hu, XiaoGong; Gong, XiuQiang; Liu, Li; He, Feng; Guo, Rui; Ren, Hui; Hu, GuangMing; Zhang, Lei

    2013-10-01

    The BeiDou Navigation Satellite System (BDS) provides Radio Navigation Service System (RNSS) as well as Radio Determination Service System (RDSS). RDSS users can obtain positioning by responding the Master Control Center (MCC) inquiries to signal transmitted via GEO satellite transponder. The positioning result can be calculated with elevation constraint by MCC. The primary error sources affecting the RDSS positioning accuracy are the RDSS signal transceiver delay, atmospheric trans-mission delay and GEO satellite position error. During GEO orbit maneuver, poor orbit forecast accuracy significantly impacts RDSS services. A real-time 3-D orbital correction method based on wide-area differential technique is raised to correct the orbital error. Results from the observation shows that the method can successfully improve positioning precision during orbital maneuver, independent from the RDSS reference station. This improvement can reach 50% in maximum. Accurate calibration of the RDSS signal transceiver delay precision and digital elevation map may have a critical role in high precise RDSS positioning services.

  18. Continuity of Earth Radiation Budget Observations

    Science.gov (United States)

    Loeb, N. G.; Su, W.; Wong, T.; Priestley, K.

    2017-12-01

    Earth's climate is determined by the exchange of radiant energy between the Sun, Earth and space. The absorbed solar radiation at the top-of-atmosphere (TOA) fuels the climate system, providing the energy required for atmospheric and oceanic motions. Earth's radiation budget (ERB) involves a balance between how much solar energy Earth absorbs and how much terrestrial thermal infrared radiation is emitted to space. Because of its critical role in climate, continuous monitoring of the ERB is necessary for improved understanding and prediction of climate variability and change. NASA's long history in observing the TOA ERB is acknowledged in the 2007 and 2013 reports of the IPCC (IPCC 2007, 2013), the 2007 NRC Decadal Survey (NRC 2007), and the GCOS implementation plan of the WMO (GCOS 2016). A key reason for NASA's success in this area is due to its support of the CERES Project and its predecessor, ERBE. During ERBE, the TOA ERB was observed using both scanner and nonscanner broadband instruments. The CERES project consists of six scanner instruments flying alongside high-resolution spectral imagers (MODIS, VIIRS) in morning and afternoon sun-synchronous orbits. In addition to extending the ERBE TOA radiation budget record, CERES also provides observations of Earth's surface radiation budget with unprecedented accuracy. Here we assess the likelihood of a measurement gap in the ERB record. We show that unless a follow-on ERB instrument to the last available CERES copy (FM6) is built and launched, there is a significant risk of a measurement gap in the ERB record by the mid-2020s. A gap is of concern not only because the ERB would not be monitored during the gap period but also because it would be exceedingly difficult to tie the records before and after the gap together with sufficient accuracy for climate analyses. While ERB instruments are highly stable temporally, they lack the absolute accuracy needed to bridge a gap. Consequently, there is a requirement that

  19. A Systematic Review and Meta-analysis of the Diagnostic Accuracy of Prostate Health Index and 4-Kallikrein Panel Score in Predicting Overall and High-grade Prostate Cancer.

    Science.gov (United States)

    Russo, Giorgio Ivan; Regis, Federica; Castelli, Tommaso; Favilla, Vincenzo; Privitera, Salvatore; Giardina, Raimondo; Cimino, Sebastiano; Morgia, Giuseppe

    2017-08-01

    Markers for prostate cancer (PCa) have progressed over recent years. In particular, the prostate health index (PHI) and the 4-kallikrein (4K) panel have been demonstrated to improve the diagnosis of PCa. We aimed to review the diagnostic accuracy of PHI and the 4K panel for PCa detection. We performed a systematic literature search of PubMed, EMBASE, Cochrane, and Academic One File databases until July 2016. We included diagnostic accuracy studies that used PHI or 4K panel for the diagnosis of PCa or high-grade PCa. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Twenty-eight studies including 16,762 patients have been included for the analysis. The pooled data showed a sensitivity of 0.89 and 0.74 for PHI and 4K panel, respectively, for PCa detection and a pooled specificity of 0.34 and 0.60 for PHI and 4K panel, respectively. The derived area under the curve (AUC) from the hierarchical summary receiver operating characteristic (HSROC) showed an accuracy of 0.76 and 0.72 for PHI and 4K panel respectively. For high-grade PCa detection, the pooled sensitivity was 0.93 and 0.87 for PHI and 4K panel, respectively, whereas the pooled specificity was 0.34 and 0.61 for PHI and 4K panel, respectively. The derived AUC from the HSROC showed an accuracy of 0.82 and 0.81 for PHI and 4K panel, respectively. Both PHI and the 4K panel provided good diagnostic accuracy in detecting overall and high-grade PCa. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. High-accuracy continuous airborne measurements of greenhouse gases (CO2 and CH4) during BARCA

    Science.gov (United States)

    Chen, H.; Winderlich, J.; Gerbig, C.; Hoefer, A.; Rella, C. W.; Crosson, E. R.; van Pelt, A. D.; Steinbach, J.; Kolle, O.; Beck, V.; Daube, B. C.; Gottlieb, E. W.; Chow, V. Y.; Santoni, G. W.; Wofsy, S. C.

    2009-12-01

    High-accuracy continuous measurements of greenhouse gases (CO2 and CH4) during the BARCA (Balanço Atmosférico Regional de Carbono na Amazônia) phase B campaign in Brazil in May 2009 were accomplished using a newly available analyzer based on the cavity ring-down spectroscopy (CRDS) technique. This analyzer was flown without a drying system or any in-flight calibration gases. Water vapor corrections associated with dilution and pressure-broadening effects for CO2 and CH4 were derived from laboratory experiments employing measurements of water vapor by the CRDS analyzer. Before the campaign, the stability of the analyzer was assessed by laboratory tests under simulated flight conditions. During the campaign, a comparison of CO2 measurements between the CRDS analyzer and a nondispersive infrared (NDIR) analyzer on board the same aircraft showed a mean difference of 0.22±0.09 ppm for all flights over the Amazon rain forest. At the end of the campaign, CO2 concentrations of the synthetic calibration gases used by the NDIR analyzer were determined by the CRDS analyzer. After correcting for the isotope and the pressure-broadening effects that resulted from changes of the composition of synthetic vs. ambient air, and applying those concentrations as calibrated values of the calibration gases to reprocess the CO2 measurements made by the NDIR, the mean difference between the CRDS and the NDIR during BARCA was reduced to 0.05±0.09 ppm, with the mean standard deviation of 0.23±0.05 ppm. The results clearly show that the CRDS is sufficiently stable to be used in flight without drying the air or calibrating in flight and the water corrections are fully adequate for high-accuracy continuous airborne measurements of CO2 and CH4.

  1. Combined Scintigraphy and Tumor Marker Analysis Predicts Unfavorable Histopathology of Neuroblastic Tumors with High Accuracy.

    Directory of Open Access Journals (Sweden)

    Wolfgang Peter Fendler

    Full Text Available Our aim was to improve the prediction of unfavorable histopathology (UH in neuroblastic tumors through combined imaging and biochemical parameters.123I-MIBG SPECT and MRI was performed before surgical resection or biopsy in 47 consecutive pediatric patients with neuroblastic tumor. Semi-quantitative tumor-to-liver count-rate ratio (TLCRR, MRI tumor size and margins, urine catecholamine and NSE blood levels of neuron specific enolase (NSE were recorded. Accuracy of single and combined variables for prediction of UH was tested by ROC analysis with Bonferroni correction.34 of 47 patients had UH based on the International Neuroblastoma Pathology Classification (INPC. TLCRR and serum NSE both predicted UH with moderate accuracy. Optimal cut-off for TLCRR was 2.0, resulting in 68% sensitivity and 100% specificity (AUC-ROC 0.86, p < 0.001. Optimal cut-off for NSE was 25.8 ng/ml, resulting in 74% sensitivity and 85% specificity (AUC-ROC 0.81, p = 0.001. Combination of TLCRR/NSE criteria reduced false negative findings from 11/9 to only five, with improved sensitivity and specificity of 85% (AUC-ROC 0.85, p < 0.001.Strong 123I-MIBG uptake and high serum level of NSE were each predictive of UH. Combined analysis of both parameters improved the prediction of UH in patients with neuroblastic tumor. MRI parameters and urine catecholamine levels did not predict UH.

  2. Science, technology and mission design for LATOR experiment

    Science.gov (United States)

    Turyshev, Slava G.; Shao, Michael; Nordtvedt, Kenneth L.

    2017-11-01

    The Laser Astrometric Test of Relativity (LATOR) is a Michelson-Morley-type experiment designed to test the Einstein's general theory of relativity in the most intense gravitational environment available in the solar system - the close proximity to the Sun. By using independent time-series of highly accurate measurements of the Shapiro time-delay (laser ranging accurate to 1 cm) and interferometric astrometry (accurate to 0.1 picoradian), LATOR will measure gravitational deflection of light by the solar gravity with accuracy of 1 part in a billion, a factor {30,000 better than currently available. LATOR will perform series of highly-accurate tests of gravitation and cosmology in its search for cosmological remnants of scalar field in the solar system. We present science, technology and mission design for the LATOR mission.

  3. Instrumentation for high-frequency meteorological observations from research vessel

    Digital Repository Service at National Institute of Oceanography (India)

    VijayKumar, K.; Khalap, S.; Mehra, P.

    Ship provides an attractive platform from which high-frequency meteorological observations (e.g., wind components, water vapor density, and air temperature) can be made accurately. However, accurate observations of meteorological variables depend...

  4. Improved imputation accuracy of rare and low-frequency variants using population-specific high-coverage WGS-based imputation reference panel.

    Science.gov (United States)

    Mitt, Mario; Kals, Mart; Pärn, Kalle; Gabriel, Stacey B; Lander, Eric S; Palotie, Aarno; Ripatti, Samuli; Morris, Andrew P; Metspalu, Andres; Esko, Tõnu; Mägi, Reedik; Palta, Priit

    2017-06-01

    Genetic imputation is a cost-efficient way to improve the power and resolution of genome-wide association (GWA) studies. Current publicly accessible imputation reference panels accurately predict genotypes for common variants with minor allele frequency (MAF)≥5% and low-frequency variants (0.5≤MAF<5%) across diverse populations, but the imputation of rare variation (MAF<0.5%) is still rather limited. In the current study, we evaluate imputation accuracy achieved with reference panels from diverse populations with a population-specific high-coverage (30 ×) whole-genome sequencing (WGS) based reference panel, comprising of 2244 Estonian individuals (0.25% of adult Estonians). Although the Estonian-specific panel contains fewer haplotypes and variants, the imputation confidence and accuracy of imputed low-frequency and rare variants was significantly higher. The results indicate the utility of population-specific reference panels for human genetic studies.

  5. High-accuracy continuous airborne measurements of greenhouse gases (CO2 and CH4) using the cavity ring-down spectroscopy (CRDS) technique

    NARCIS (Netherlands)

    Chen, H.; Winderlich, J.; Gerbig, C.; Hoefer, A.; Rella, C. W.; Crosson, E. R.; Van Pelt, A. D.; Steinbach, J.; Kolle, O.; Beck, V.; Daube, B. C.; Gottlieb, E. W.; Chow, V. Y.; Santoni, G. W.; Wofsy, S. C.

    2010-01-01

    High-accuracy continuous measurements of greenhouse gases (CO2 and CH4) during the BARCA (Balancao Atmosferico Regional de Carbono na Amazonia) phase B campaign in Brazil in May 2009 were accomplished using a newly available analyzer based on the cavity ring-down spectroscopy (CRDS) technique. This

  6. Diagnostic accuracy of sonography for pleural effusion: systematic review

    Directory of Open Access Journals (Sweden)

    Alexandre Grimberg

    Full Text Available CONTEXT AND OBJECTIVE: The initial method for evaluating the presence of pleural effusion was chest radiography. Isolated studies have shown that sonography has greater accuracy than radiography for this diagnosis; however, no systematic reviews on this matter are available in the literature. Thus, the aim of this study was to evaluate the accuracy of sonography in detecting pleural effusion, by means of a systematic review of the literature. DESIGN AND SETTING: This was a systematic review with meta-analysis on accuracy studies. This study was conducted in the Department of Diagnostic Imaging and in the Brazilian Cochrane Center, Discipline of Emergency Medicine and Evidence-Based Medicine, Department of Medicine, Universidade Federal de São Paulo (Unifesp, São Paulo, Brazil. METHOD: The following databases were searched: Cochrane Library, Medline, Web of Science, Embase and Literatura Latino-Americana e do Caribe em Ciências da Saúde (Lilacs. The references of relevant studies were also screened for additional citations of interest. Studies in which the accuracy of sonography for detecting pleural effusion was tested, with an acceptable reference standard (computed tomography or thoracic drainage, were included. RESULTS: Four studies were included. All of them showed that sonography had high sensitivity, specificity and accuracy for detecting pleural effusions. The mean sensitivity was 93% (95% confidence interval, CI: 89% to 96%, and specificity was 96% (95% CI: 95% to 98%. CONCLUSIONS: In different populations and clinical settings, sonography showed consistently high sensitivity, specificity and accuracy for detecting fluid in the pleural space.

  7. Diagnostic accuracy of ultrasound in upper and lower extremity long bone fractures of emergency department trauma patients.

    Science.gov (United States)

    Frouzan, Arash; Masoumi, Kambiz; Delirroyfard, Ali; Mazdaie, Behnaz; Bagherzadegan, Elnaz

    2017-08-01

    Long bone fractures are common injuries caused by trauma. Some studies have demonstrated that ultrasound has a high sensitivity and specificity in the diagnosis of upper and lower extremity long bone fractures. The aim of this study was to determine the accuracy of ultrasound compared with plain radiography in diagnosis of upper and lower extremity long bone fractures in traumatic patients. This cross-sectional study assessed 100 patients admitted to the emergency department of Imam Khomeini Hospital, Ahvaz, Iran with trauma to the upper and lower extremities, from September 2014 through October 2015. In all patients, first ultrasound and then standard plain radiography for the upper and lower limb was performed. Data were analyzed by SPSS version 21 to determine the specificity and sensitivity. The mean age of patients with upper and lower limb trauma were 31.43±12.32 years and 29.63±5.89 years, respectively. Radius fracture was the most frequent compared to other fractures (27%). Sensitivity, specificity, positive predicted value, and negative predicted value of ultrasound compared with plain radiography in the diagnosis of upper extremity long bones were 95.3%, 87.7%, 87.2% and 96.2%, respectively, and the highest accuracy was observed in left arm fractures (100%). Tibia and fibula fractures were the most frequent types compared to other fractures (89.2%). Sensitivity, specificity, PPV and NPV of ultrasound compared with plain radiography in the diagnosis of upper extremity long bone fractures were 98.6%, 83%, 65.4% and 87.1%, respectively, and the highest accuracy was observed in men, lower ages and femoral fractures. The results of this study showed that ultrasound compared with plain radiography has a high accuracy in the diagnosis of upper and lower extremity long bone fractures.

  8. High-Resolution Assimilation of GRACE Terrestrial Water Storage Observations to Represent Local-Scale Water Table Depths

    Science.gov (United States)

    Stampoulis, D.; Reager, J. T., II; David, C. H.; Famiglietti, J. S.; Andreadis, K.

    2017-12-01

    Despite the numerous advances in hydrologic modeling and improvements in Land Surface Models, an accurate representation of the water table depth (WTD) still does not exist. Data assimilation of observations of the joint NASA and DLR mission, Gravity Recovery and Climate Experiment (GRACE) leads to statistically significant improvements in the accuracy of hydrologic models, ultimately resulting in more reliable estimates of water storage. However, the usually shallow groundwater compartment of the models presents a problem with GRACE assimilation techniques, as these satellite observations account for much deeper aquifers. To improve the accuracy of groundwater estimates and allow the representation of the WTD at fine spatial scales we implemented a novel approach that enables a large-scale data integration system to assimilate GRACE data. This was achieved by augmenting the Variable Infiltration Capacity (VIC) hydrologic model, which is the core component of the Regional Hydrologic Extremes Assessment System (RHEAS), a high-resolution modeling framework developed at the Jet Propulsion Laboratory (JPL) for hydrologic modeling and data assimilation. The model has insufficient subsurface characterization and therefore, to reproduce groundwater variability not only in shallow depths but also in deep aquifers, as well as to allow GRACE assimilation, a fourth soil layer of varying depth ( 1000 meters) was added in VIC as the bottom layer. To initialize a water table in the model we used gridded global WTD data at 1 km resolution which were spatially aggregated to match the model's resolution. Simulations were then performed to test the augmented model's ability to capture seasonal and inter-annual trends of groundwater. The 4-layer version of VIC was run with and without assimilating GRACE Total Water Storage anomalies (TWSA) over the Central Valley in California. This is the first-ever assimilation of GRACE TWSA for the determination of realistic water table depths, at

  9. Alternatives to accuracy and bias metrics based on percentage errors for radiation belt modeling applications

    Energy Technology Data Exchange (ETDEWEB)

    Morley, Steven Karl [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-07-01

    This report reviews existing literature describing forecast accuracy metrics, concentrating on those based on relative errors and percentage errors. We then review how the most common of these metrics, the mean absolute percentage error (MAPE), has been applied in recent radiation belt modeling literature. Finally, we describe metrics based on the ratios of predicted to observed values (the accuracy ratio) that address the drawbacks inherent in using MAPE. Specifically, we define and recommend the median log accuracy ratio as a measure of bias and the median symmetric accuracy as a measure of accuracy.

  10. Contributions of speed and accuracy to translational selection in bacteria.

    Directory of Open Access Journals (Sweden)

    Wenqi Ran

    Full Text Available Among bacteria, we have previously shown that species that are capable of rapid growth have stronger selection on codon usage than slow growing species, and possess higher numbers of rRNA and tRNA genes. This suggests that fast-growers are adapted for fast protein synthesis. There is also considerable evidence that codon usage is influenced by accuracy of translation, and some authors have argued that accuracy is more important than speed. Here we compare the strength of the two effects by studying the codon usages in high and low expression genes and on conserved and variable sites within high expression genes. We introduce a simple statistical method that can be used to assess the significance and the strength of the two types of bias in the same sets of sequences. We compare our statistical measure of codon bias to the common used codon adaptation index, and show that the new measure is preferable for three reasons for the purposes of this analysis. Across a large sample of bacterial genomes, both effects from speed and accuracy are clearly visible, although the speed effect appears to be much stronger than the accuracy effect and is found to be significant in a larger proportion of genomes. It is also difficult to explain the correlation of codon bias in the high expression genes with growth rates and numbers of copies of tRNA and rRNA genes on the basis of selection for accuracy. Hence we conclude that selection for translational speed is a dominant effect in driving codon usage bias in fast-growing bacteria, with selection for accuracy playing a small supplementary role.

  11. A study on temporal accuracy of OpenFOAM

    Directory of Open Access Journals (Sweden)

    Sang Bong Lee

    2017-07-01

    Full Text Available Crank–Nicolson scheme in native OpenFOAM source libraries was not able to provide 2nd order temporal accuracy of velocity and pressure since the volume flux of convective nonlinear terms was 1st accurate in time. In the present study the simplest way of getting the volume flux with 2nd order accuracy was proposed by using old fluxes. A possible numerical instability originated from an explicit estimation of volume fluxes could be handled by introducing a weighting factor which was determined by observing the ratio of the finally corrected volume flux to the intermediate volume flux at the previous step. The new calculation of volume fluxes was able to provide temporally accurate velocity and pressure with 2nd order. The improvement of temporal accuracy was validated by performing numerical simulations of 2D Taylor–Green vortex of which an exact solution was known and 2D vortex shedding from a circular cylinder.

  12. A design of optical modulation system with pixel-level modulation accuracy

    Science.gov (United States)

    Zheng, Shiwei; Qu, Xinghua; Feng, Wei; Liang, Baoqiu

    2018-01-01

    Vision measurement has been widely used in the field of dimensional measurement and surface metrology. However, traditional methods of vision measurement have many limits such as low dynamic range and poor reconfigurability. The optical modulation system before image formation has the advantage of high dynamic range, high accuracy and more flexibility, and the modulation accuracy is the key parameter which determines the accuracy and effectiveness of optical modulation system. In this paper, an optical modulation system with pixel level accuracy is designed and built based on multi-points reflective imaging theory and digital micromirror device (DMD). The system consisted of digital micromirror device, CCD camera and lens. Firstly we achieved accurate pixel-to-pixel correspondence between the DMD mirrors and the CCD pixels by moire fringe and an image processing of sampling and interpolation. Then we built three coordinate systems and calculated the mathematic relationship between the coordinate of digital micro-mirror and CCD pixels using a checkerboard pattern. A verification experiment proves that the correspondence error is less than 0.5 pixel. The results show that the modulation accuracy of system meets the requirements of modulation. Furthermore, the high reflecting edge of a metal circular piece can be detected using the system, which proves the effectiveness of the optical modulation system.

  13. Chattering-free sliding mode observer for speed sensorless control of PMSM

    Directory of Open Access Journals (Sweden)

    Mahmoud M. Gaballah

    2017-07-01

    Full Text Available This article presents a new speed observer based on fuzzy logic for speed sensorless control applications of permanent magnet synchronous motor “PMSM”. The switch function in traditional Sliding Mode Observer “SMO” is replaced by a rule based fuzzy logic system. The proposed observer not only improves the system dynamic performance during disturbances or parameter variations, but also has a high accuracy tracking performance with sufficient chattering reduction. The validity of the new observer corroborated through experimental results using TMS320F28069M Digital Signal Processor “DSP”.

  14. Metabolomic database annotations via query of elemental compositions: Mass accuracy is insufficient even at less than 1 ppm

    Directory of Open Access Journals (Sweden)

    Fiehn Oliver

    2006-04-01

    Full Text Available Abstract Background Metabolomic studies are targeted at identifying and quantifying all metabolites in a given biological context. Among the tools used for metabolomic research, mass spectrometry is one of the most powerful tools. However, metabolomics by mass spectrometry always reveals a high number of unknown compounds which complicate in depth mechanistic or biochemical understanding. In principle, mass spectrometry can be utilized within strategies of de novo structure elucidation of small molecules, starting with the computation of the elemental composition of an unknown metabolite using accurate masses with errors Results High mass accuracy (95% of false candidates. This orthogonal filter can condense several thousand candidates down to only a small number of molecular formulas. Example calculations for 10, 5, 3, 1 and 0.1 ppm mass accuracy are given. Corresponding software scripts can be downloaded from http://fiehnlab.ucdavis.edu. A comparison of eight chemical databases revealed that PubChem and the Dictionary of Natural Products can be recommended for automatic queries using molecular formulae. Conclusion More than 1.6 million molecular formulae in the range 0–500 Da were generated in an exhaustive manner under strict observation of mathematical and chemical rules. Assuming that ion species are fully resolved (either by chromatography or by high resolution mass spectrometry, we conclude that a mass spectrometer capable of 3 ppm mass accuracy and 2% error for isotopic abundance patterns outperforms mass spectrometers with less than 1 ppm mass accuracy or even hypothetical mass spectrometers with 0.1 ppm mass accuracy that do not include isotope information in the calculation of molecular formulae.

  15. Designing informative warning signals: Effects of indicator type, modality, and task demand on recognition speed and accuracy

    Science.gov (United States)

    Stevens, Catherine J.; Brennan, David; Petocz, Agnes; Howell, Clare

    2009-01-01

    An experiment investigated the assumption that natural indicators which exploit existing learned associations between a signal and an event make more effective warnings than previously unlearned symbolic indicators. Signal modality (visual, auditory) and task demand (low, high) were also manipulated. Warning effectiveness was indexed by accuracy and reaction time (RT) recorded during training and dual task test phases. Thirty-six participants were trained to recognize 4 natural and 4 symbolic indicators, either visual or auditory, paired with critical incidents from an aviation context. As hypothesized, accuracy was greater and RT was faster in response to natural indicators during the training phase. This pattern of responding was upheld in test phase conditions with respect to accuracy but observed in RT only in test phase conditions involving high demand and the auditory modality. Using the experiment as a specific example, we argue for the importance of considering the cognitive contribution of the user (viz., prior learned associations) in the warning design process. Drawing on semiotics and cognitive psychology, we highlight the indexical nature of so-called auditory icons or natural indicators and argue that the cogniser is an indispensable element in the tripartite nature of signification. PMID:20523852

  16. Gaia DR1 documentation

    Science.gov (United States)

    van Leeuwen, F.; de Bruijne, J. H. J.; Arenou, F.; Comoretto, G.; Eyer, L.; Farras Casas, M.; Hambly, N.; Hobbs, D.; Salgado, J.; Utrilla Molina, E.; Vogt, S.; van Leeuwen, M.; Abreu, A.; Altmann, M.; Andrei, A.; Babusiaux, C.; Bastian, U.; Biermann, M.; Blanco-Cuaresma, S.; Bombrun, A.; Borrachero, R.; Brown, A. G. A.; Busonero, D.; Busso, G.; Butkevich, A.; Cantat-Gaudin, T.; Carrasco, J. M.; Castañeda, J.; Charnas, J.; Cheek, N.; Clementini, G.; Crowley, C.; Cuypers, J.; Davidson, M.; De Angeli, F.; De Ridder, J.; Evans, D.; Fabricius, C.; Findeisen, K.; Fleitas, J. M.; Gracia, G.; Guerra, R.; Guy, L.; Helmi, A.; Hernandez, J.; Holl, B.; Hutton, A.; Klioner, S.; Lammers, U.; Lecoeur-Taïbi, I.; Lindegren, L.; Luri, X.; Marinoni, S.; Marrese, P.; Messineo, R.; Michalik, D.; Mignard, F.; Montegriffo, P.; Mora, A.; Mowlavi, N.; Nienartowicz, K.; Pancino, E.; Panem, C.; Portell, J.; Rimoldini, L.; Riva, A.; Robin, A.; Siddiqui, H.; Smart, R.; Sordo, R.; Soria, S.; Turon, C.; Vallenari, A.; Voss, H.

    2017-12-01

    We present the first Gaia data release, Gaia DR1, consisting of astrometry and photometry for over 1 billion sources brighter than magnitude 20.7 in the white-light photometric band G of Gaia. The Gaia Data Processing and Analysis Consortium (DPAC) processed the raw measurements collected with the Gaia instruments during the first 14 months of the mission, and turned these into an astrometric and photometric catalogue. Gaia DR1 consists of three parts: an astrometric data set which contains the positions, parallaxes, and mean proper motions for about 2 million of the brightest stars in common with the Hipparcos and Tycho-2 catalogues (the primary astrometric data set) and the positions for an additional 1.1 billion sources (the secondary astrometric data set). The primary set forms the realisation of the Tycho-Gaia Astrometric Solution (TGAS). The second part of Gaia DR1 is the photometric data set, which contains the mean G-band magnitudes for all sources. The third part consists of the G-band light curves and the characteristics of 3000 Cepheid and RR Lyrae stars observed at high cadence around the south ecliptic pole. The positions and proper motions in the astrometric data set are given in a reference frame that is aligned with the International Celestial Reference Frame (ICRF) to better than 0.1 mas at epoch J2015.0, and non-rotating with respect to the ICRF to within 0.03 mas yr^-1. For the primary astrometric data set, the typical standard error for the positions and parallaxes is about 0.3 mas, while for the proper motions the typical standard error is about 1 mas yr^-1. Whereas it has been suggested in Gaia Collaboration et al. (2016a) that a systematic component of ∼0.3 mas should be 'added' (in quadrature) to the parallax uncertainties, Brown (2017) clarifies that reported parallax standard errors already include local systematics as a result of the calibration of the TGAS parallax uncertainties by comparison to Hipparcos parallaxes. For the subset of

  17. Geometric distortion of F255W for WFPC2 Cycle 12

    Science.gov (United States)

    Kozhurina-Platais, Vera

    2003-07-01

    The goal of astrometric calibration of the HST WFPC2 is to obtain a coordinate system free of distortion down to the precision level of 1 mas. That precision is necessary for future astrometric work {e.g., on proper motions} involving a combination of the archival WFPC2 and recent ACS images. So far such a calibration has only been obtained for the wide bandpass F555W filter {Anderson and King, 2003}. Recently V. Kozhurina-Platais {ISR, 2003-002} has expanded the analysis of the geometric distortion of WFPC2 as a function of wavelength for two other broadband filters, {F814W and F300W}, and has also established the plate scale and skew parameters {non-perpendicularity of X and Y axes} for these filters. This study points to the importance of astrometric calibration at wavelengths shorter than 400 nanometers. This proposal seeks observations in the FUV filter F255W of the Inner Calibration Field in the globular cluster omega Cen. It is expected that the amount of distortion in the F255W filter with respect to the F555W filter will be higher by 5% but this must be established from observations. A total of four astrometric calibrations in F255W {proposed here}, and F300W, F555, F814W {already completed} will allow us to interpolate such a calibration for any other filter from FUV to near infrared.

  18. Measurement of high-energy (10–60 keV) x-ray spectral line widths with eV accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Seely, J. F., E-mail: seelyjf@gmail.com; Feldman, U. [Artep Inc., 2922 Excelsior Springs Court, Ellicott City, Maryland 21042 (United States); Glover, J. L.; Hudson, L. T.; Ralchenko, Y.; Henins, Albert [National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Pereira, N. [Ecopulse Inc., P. O. Box 528, Springfield, Virginia 22152 (United States); Di Stefano, C. A.; Kuranz, C. C.; Drake, R. P. [University of Michigan, Ann Arbor, Michigan 48109 (United States); Chen, Hui; Williams, G. J.; Park, J. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States)

    2014-11-15

    A high resolution crystal spectrometer utilizing a crystal in transmission geometry has been developed and experimentally optimized to measure the widths of emission lines in the 10–60 keV energy range with eV accuracy. The spectrometer achieves high spectral resolution by utilizing crystal planes with small lattice spacings (down to 2d = 0.099 nm), a large crystal bending radius and Rowland circle diameter (965 mm), and an image plate detector with high spatial resolution (60 μm in the case of the Fuji TR image plate). High resolution W L-shell and K-shell laboratory test spectra in the 10–60 keV range and Ho K-shell spectra near 47 keV recorded at the LLNL Titan laser facility are presented. The Ho K-shell spectra are the highest resolution hard x-ray spectra recorded from a solid target irradiated by a high-intensity laser.

  19. Acquisition of decision making criteria: reward rate ultimately beats accuracy.

    Science.gov (United States)

    Balci, Fuat; Simen, Patrick; Niyogi, Ritwik; Saxe, Andrew; Hughes, Jessica A; Holmes, Philip; Cohen, Jonathan D

    2011-02-01

    Speed-accuracy trade-offs strongly influence the rate of reward that can be earned in many decision-making tasks. Previous reports suggest that human participants often adopt suboptimal speed-accuracy trade-offs in single session, two-alternative forced-choice tasks. We investigated whether humans acquired optimal speed-accuracy trade-offs when extensively trained with multiple signal qualities. When performance was characterized in terms of decision time and accuracy, our participants eventually performed nearly optimally in the case of higher signal qualities. Rather than adopting decision criteria that were individually optimal for each signal quality, participants adopted a single threshold that was nearly optimal for most signal qualities. However, setting a single threshold for different coherence conditions resulted in only negligible decrements in the maximum possible reward rate. Finally, we tested two hypotheses regarding the possible sources of suboptimal performance: (1) favoring accuracy over reward rate and (2) misestimating the reward rate due to timing uncertainty. Our findings provide support for both hypotheses, but also for the hypothesis that participants can learn to approach optimality. We find specifically that an accuracy bias dominates early performance, but diminishes greatly with practice. The residual discrepancy between optimal and observed performance can be explained by an adaptive response to uncertainty in time estimation.

  20. THE ACCURACY OF SCHEFFE'S THIRD DEGREE OVER SECOND ...

    African Journals Online (AJOL)

    NIJOTECH

    Scheffe's (1958), simplex theory to optimize the compressive strength of concrete made from RHA pozzolan based on (4,2) and (4,3) simplex lattices. The strengths predicted by the models are in good agreement with their corresponding experimentally observed values. The accuracy of strength predicted by the third degree ...