WorldWideScience

Sample records for high volume high volume

  1. Indigenous high volume air sampler

    International Nuclear Information System (INIS)

    Kotrappa, P.; Setty, N.P.N.; Raghunath, B.; Sivasubrahmanyam, P.S.

    1978-01-01

    A high volume air sampler for use in assessing concentrations of low levels of air borne particulates has been fabricated. The sampler will be of use in radioactive installations, conventional industries and environmental pollution analysis. It is comparable in performance with the imported Staplex air samplers. A turbine and motor system similar to the one found in conventional vacuum cleaners is used in its design. The sampler units can be produced in large numbers. (M.G.B.)

  2. When high-volume PCI operators in high-volume hospitals move to lower volume hospitals-Do they still maintain high volume and quality of outcomes?

    Science.gov (United States)

    Lu, Tsung-Hsueh; Li, Sheng-Tun; Liang, Fu-Wen; Lee, Jo-Chi; Yin, Wei-Hsian

    2017-10-31

    The aim of this quasi-experimental study was to examine whether high-volume percutaneous coronary intervention (PCI) operators still maintain high volume and quality of outcomes when they moved to lower volume hospitals. Systematic reviews have indicated that high-volume PCI operators and hospitals have higher quality outcomes. However, little is known on whether high PCI volume and high quality outcomes are mainly due to operator characteristics (i.e., skill and experience) and is portable across organizations or whether it is due to hospital characteristics (i.e., equipment, team, and management system) and is less portable. We used Taiwan National Health Insurance claims data 2000-2012 to identify 98 high-volume PCI operators, 10 of whom moved from one hospital to another during the study period. We compared the PCI volume, risk-adjusted mortality ratio, and major adverse cardiovascular event (MACE) ratio before and after moving. Of the 10 high-volume operators who moved, 6 moved from high- to moderate- or low-volume hospitals, with median annual PCI volumes (interquartile range) of 130 (117-165) in prior hospitals and 54 (46-84) in subsequent hospitals (the hospital the operator moved to), and the remaining 4 moved from high to high-volume hospitals, with median annual PCI volumes (interquartile range) of 151 (133-162) in prior hospitals and 193 (178-239) in subsequent hospitals. No significant differences were observed in the risk-adjusted mortality ratios and MACE ratios between high-volume operators and matched controls before and after moving. High-volume operators cannot maintain high volume when they moved from high to moderate or low-volume hospitals; however, the quality of care is maintained. High PCI volume and high-quality outcomes are less portable and more hospital bound. © 2017 Wiley Periodicals, Inc.

  3. High volume medical web sites.

    Science.gov (United States)

    Elliott, B; Elliott, G

    2000-01-01

    In 1998, 22 million individuals reported surfing the web for medical information, and this number will increase to over 30 million by 2000. Fifteen of the highest volume medical web sites are described in this paper. Sponsorship and/or ownership of the fifteen sites varied. The government sponsors one, and some are the products of well-known educational institutions. One site is supported by a consumer health organization, and the American Medical Association was in the top 15. However, the most common owners are commercial, for-profit businesses. Attributes of the ideal site were categorized, and include a robust privacy and disclosure statement with an emphasis on education and an appropriate role for advertising. The covering of Complementary and Alternative Medicine (CAM) should be in a balanced and unbiased manner. There has to be an emphasis on knowledge based evidence as opposed to testimonials, and sources should be timely and reviewed. Bibliographies of authors need to be available. Hyperlinking to other web resources is valuable, as even the largest of sites cannot come close to covering all of medicine.

  4. High Production Volume Information System (HPVIS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The High Production Volume Information System (HPVIS) provides access to select health and environmental effect information on chemicals that are manufactured in...

  5. MANAGING HIGH-END, HIGH-VOLUME INNOVATIVE PRODUCTS

    Directory of Open Access Journals (Sweden)

    Gembong Baskoro

    2008-01-01

    Full Text Available This paper discuses the concept of managing high-end, high-volume innovative products. High-end, high-volume consumer products are products that have considerable influence to the way of life. Characteristic of High-end, high-volume consumer products are (1 short cycle time, (2 quick obsolete time, and (3 rapid price erosion. Beside the disadvantages that they are high risk for manufacturers, if manufacturers are able to understand precisely the consumer needs then they have the potential benefit or success to be the market leader. High innovation implies to high utilization of the user, therefore these products can influence indirectly to the way of people life. The objective of managing them is to achieve sustainability of the products development and innovation. This paper observes the behavior of these products in companies operated in high-end, high-volume consumer product.

  6. High tidal volume ventilation in infant mice.

    Science.gov (United States)

    Cannizzaro, Vincenzo; Zosky, Graeme R; Hantos, Zoltán; Turner, Debra J; Sly, Peter D

    2008-06-30

    Infant mice were ventilated with either high tidal volume (V(T)) with zero end-expiratory pressure (HVZ), high V(T) with positive end-expiratory pressure (PEEP) (HVP), or low V(T) with PEEP. Thoracic gas volume (TGV) was determined plethysmographically and low-frequency forced oscillations were used to measure the input impedance of the respiratory system. Inflammatory cells, total protein, and cytokines in bronchoalveolar lavage fluid (BALF) and interleukin-6 (IL-6) in serum were measured as markers of pulmonary and systemic inflammatory response, respectively. Coefficients of tissue damping and tissue elastance increased in all ventilated mice, with the largest rise seen in the HVZ group where TGV rapidly decreased. BALF protein levels increased in the HVP group, whereas serum IL-6 rose in the HVZ group. PEEP keeps the lungs open, but provides high volumes to the entire lungs and induces lung injury. Compared to studies in adult and non-neonatal rodents, infant mice demonstrate a different response to similar ventilation strategies underscoring the need for age-specific animal models.

  7. High resolution gas volume change sensor

    International Nuclear Information System (INIS)

    Dirckx, Joris J. J.; Aernouts, Jef E. F.; Aerts, Johan R. M.

    2007-01-01

    Changes of gas quantity in a system can be measured either by measuring pressure changes or by measuring volume changes. As sensitive pressure sensors are readily available, pressure change is the commonly used technique. In many physiologic systems, however, buildup of pressure influences the gas exchange mechanisms, thus changing the gas quantity change rate. If one wants to study the gas flow in or out of a biological gas pocket, measurements need to be done at constant pressure. In this article we present a highly sensitive sensor for quantitative measurements of gas volume change at constant pressure. The sensor is based on optical detection of the movement of a droplet of fluid enclosed in a capillary. The device is easy to use and delivers gas volume data at a rate of more than 15 measurements/s and a resolution better than 0.06 μl. At the onset of a gas quantity change the sensor shows a small pressure artifact of less than 15 Pa, and at constant change rates the pressure artifact is smaller than 10 Pa or 0.01% of ambient pressure

  8. High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems

    Energy Technology Data Exchange (ETDEWEB)

    Turnquist, Norman [GE Global Research, Munchen (Germany); Qi, Xuele [GE Global Research, Munchen (Germany); Raminosoa, Tsarafidy [GE Global Research, Munchen (Germany); Salas, Ken [GE Global Research, Munchen (Germany); Samudrala, Omprakash [GE Global Research, Munchen (Germany); Shah, Manoj [GE Global Research, Munchen (Germany); Van Dam, Jeremy [GE Global Research, Munchen (Germany); Yin, Weijun [GE Global Research, Munchen (Germany); Zia, Jalal [GE Global Research, Munchen (Germany)

    2013-12-20

    This report summarizes the progress made during the April 01, 2010 – December 30, 2013 period under Cooperative Agreement DE-EE0002752 for the U.S. Department of Energy entitled “High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems.” The overall objective of this program is to advance the technology for well fluids lifting systems to meet the foreseeable pressure, temperature, and longevity needs of the Enhanced Geothermal Systems (EGS) industry for the coming ten years. In this program, lifting system requirements for EGS wells were established via consultation with industry experts and site visits. A number of artificial lift technologies were evaluated with regard to their applicability to EGS applications; it was determined that a system based on electric submersible pump (ESP) technology was best suited to EGS. Technical barriers were identified and a component-level technology development program was undertaken to address each barrier, with the most challenging being the development of a power-dense, small diameter motor that can operate reliably in a 300°C environment for up to three years. Some of the targeted individual component technologies include permanent magnet motor construction, high-temperature insulation, dielectrics, bearings, seals, thrust washers, and pump impellers/diffusers. Advances were also made in thermal management of electric motors. In addition to the overall system design for a full-scale EGS application, a subscale prototype was designed and fabricated. Like the full-scale design, the subscale prototype features a novel “flow-through-the-bore” permanent magnet electric motor that combines the use of high temperature materials with an internal cooling scheme that limits peak internal temperatures to <330°C. While the full-scale high-volume multi-stage pump is designed to lift up to 80 kg/s of process water, the subscale prototype is based on a production design that can pump 20 kg/s and has been modified

  9. High-speed volume measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Lane, Michael H.; Doyle, Jr., James L.; Brinkman, Michael J.

    2018-01-30

    Disclosed is a volume sensor having a first axis, a second axis, and a third axis, each axis including a laser source configured to emit a beam; a parallel beam generating assembly configured to receive the beam and split the beam into a first parallel beam and a second parallel beam, a beam-collimating assembly configured to receive the first parallel beam and the second parallel beam and output a first beam sheet and a second beam sheet, the first beam sheet and the second beam sheet being configured to traverse the object aperture; a first collecting lens and a second collecting lens; and a first photodetector and a second photodetector, the first photodetector and the second photodetector configured to output an electrical signal proportional to the object; wherein the first axis, the second axis, and the third axis are arranged at an angular offset with respect to each other.

  10. High-order finite volume advection

    OpenAIRE

    Shaw, James

    2018-01-01

    The cubicFit advection scheme is limited to second-order convergence because it uses a polynomial reconstruction fitted to point values at cell centres. The highOrderFit advection scheme achieves higher than second order by calculating high-order moments over the mesh geometry.

  11. Study on the High Volume Reduction of Radioactive Wastes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Hong; Sik, Kang Il; Seok, Hong Dae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ho, Jeon Gil [RADIN Co. Ltd., Daejeon (Korea, Republic of)

    2013-10-15

    The solidification of radioactive wastes by the mixing method always increases their volume due to the limitation of incorporation ratio (waste/solidification agent). But if the powdered wastes can be compacted as the high density pellets and also the pellets can be filled up in a waste drum as much as possible while solidifying them with a very sticky solidification agent including a void formed in the filling step of pellets, it might be more desirable to reduce the waste volume as compared with the mixing method. So in this study, we designed and manufactured a high volume reduction machine which has the special size and shape of a pellet pocket, which the pellets can be extracted from easily and filled up in a large amount in drum, a pressurizing device to press 2 rolls, and the uniform feeding device of powder to the roll tyre. Some operational parameters which affect the formation of pellets from a powder were investigated, and then the volume reduction of a powder was evaluated. The briquetting machine, popular in general industry, was modified to apply for the volume reduction of the powered radioactive wastes (dried concentrate, sludge, spent ion-exchange resin, ash, depleted uranium powder, and etc.). In this developed high volume reduction machine, the capacity was 25 ∼ 62.5 kg/h at the optimum conditions, and the estimated volume reduction was about 2.95 (2.74/0.93) on the basis of between a powder (bulk density = 0.93 g/cm{sup 3}) and the pellet (2.74 g/cm{sup 3}). But on the basis of 200L drum, the calculated volume reduction was about 1.34 in consideration of a void volume originated in the filling step of the pellets.

  12. Perspectives on High School Reform. NCREL Viewpoints, Volume 13

    Science.gov (United States)

    Learning Point Associates / North Central Regional Educational Laboratory (NCREL), 2005

    2005-01-01

    Viewpoints is a multimedia package containing two audio CDs and a brief, informative booklet. This volume of Viewpoints focuses on issues related to high school reform. This booklet offers background information explaining the issues surrounding high school reform with perspectives from research, policy, and practice. It also provides a list of…

  13. High lung volume increases stress failure in pulmonary capillaries

    Science.gov (United States)

    Fu, Z.; Costello, M. L.; Tsukimoto, K.; Prediletto, R.; Elliott, A. R.; Mathieu-Costello, O.; West, J. B.

    1992-01-01

    We previously showed that when pulmonary capillaries in anesthetized rabbits are exposed to a transmural pressure (Ptm) of approximately 40 mmHg, stress failure of the walls occurs with disruption of the capillary endothelium, alveolar epithelium, or sometimes all layers. The present study was designed to test whether stress failure occurred more frequently at high than at low lung volumes for the same Ptm. Lungs of anesthetized rabbits were inflated to a transpulmonary pressure of 20 cmH2O, perfused with autologous blood at 32.5 or 2.5 cmH2O Ptm, and fixed by intravascular perfusion. Samples were examined by both transmission and scanning electron microscopy. The results were compared with those of a previous study in which the lung was inflated to a transpulmonary pressure of 5 cmH2O. There was a large increase in the frequency of stress failure of the capillary walls at the higher lung volume. For example, at 32.5 cmH2O Ptm, the number of endothelial breaks per millimeter cell lining was 7.1 +/- 2.2 at the high lung volume compared with 0.7 +/- 0.4 at the low lung volume. The corresponding values for epithelium were 8.5 +/- 1.6 and 0.9 +/- 0.6. Both differences were significant (P less than 0.05). At 52.5 cmH2O Ptm, the results for endothelium were 20.7 +/- 7.6 (high volume) and 7.1 +/- 2.1 (low volume), and the corresponding results for epithelium were 32.8 +/- 11.9 and 11.4 +/- 3.7. At 32.5 cmH2O Ptm, the thickness of the blood-gas barrier was greater at the higher lung volume, consistent with the development of more interstitial edema. Ballooning of the epithelium caused by accumulation of edema fluid between the epithelial cell and its basement membrane was seen at 32.5 and 52.5 cmH2O Ptm. At high lung volume, the breaks tended to be narrower and fewer were oriented perpendicular to the axis of the pulmonary capillaries than at low lung volumes. Transmission and scanning electron microscopy measurements agreed well. Our findings provide a physiological

  14. High Volume Manufacturing and Field Stability of MEMS Products

    Science.gov (United States)

    Martin, Jack

    Low volume MEMS/NEMS production is practical when an attractive concept is implemented with business, manufacturing, packaging, and test support. Moving beyond this to high volume production adds requirements on design, process control, quality, product stability, market size, market maturity, capital investment, and business systems. In a broad sense, this chapter uses a case study approach: It describes and compares the silicon-based MEMS accelerometers, pressure sensors, image projection systems, and gyroscopes that are in high volume production. Although they serve several markets, these businesses have common characteristics. For example, the manufacturing lines use automated semiconductor equipment and standard material sets to make consistent products in large quantities. Standard, well controlled processes are sometimes modified for a MEMS product. However, novel processes that cannot run with standard equipment and material sets are avoided when possible. This reliance on semiconductor tools, as well as the organizational practices required to manufacture clean, particle-free products partially explains why the MEMS market leaders are integrated circuit manufacturers. There are other factors. MEMS and NEMS are enabling technologies, so it can take several years for high volume applications to develop. Indeed, market size is usually a strong function of price. This becomes a vicious circle, because low price requires low cost - a result that is normally achieved only after a product is in high volume production. During the early years, IC companies reduced cost and financial risk by using existing facilities for low volume MEMS production. As a result, product architectures are partially determined by capabilities developed for previous products. This chapter includes a discussion of MEMS product architecture with particular attention to the impact of electronic integration, packaging, and surfaces. Packaging and testing are critical, because they are

  15. High-volume recycled materials for sustainable pavement construction.

    Science.gov (United States)

    2017-05-01

    The main objective of this research is to evaluate the feasibility of using high-volume recycled materials for concrete production in rigid pavement. The goal was to replace 50% of the solids with recycled materials and industrial by-products. The pe...

  16. Towards high-resolution positron emission tomography for small volumes

    International Nuclear Information System (INIS)

    McKee, B.T.A.

    1982-01-01

    Some arguments are made regarding the medical usefulness of high spatial resolution in positron imaging, even if limited to small imaged volumes. Then the intrinsic limitations to spatial resolution in positron imaging are discussed. The project to build a small-volume, high resolution animal research prototype (SHARP) positron imaging system is described. The components of the system, particularly the detectors, are presented and brief mention is made of data acquisition and image reconstruction methods. Finally, some preliminary imaging results are presented; a pair of isolated point sources and 18 F in the bones of a rabbit. Although the detector system is not fully completed, these first results indicate that the goals of high sensitivity and high resolution (4 mm) have been realized. (Auth.)

  17. Powder metallurgical high performance materials. Proceedings. Volume 4: late papers

    Energy Technology Data Exchange (ETDEWEB)

    Kneringer, G; Roedhammer, P; Wildner, H [eds.

    2001-07-01

    This is the fourth volume (late papers) of the 15th International Plansee seminar 2001 which general theme was 'Powder metallurgical high performance materials'. The seminar looked beyond the refractory metals and cemented carbides, which remain as its focus, to novel classes of materials, such as intermetallic compounds, with potential for high temperature applications. This volume 4 contains papers dealing with high performance P/M metals (ITER and fusion reactors, solid targets, materials microstructure, novel alloys, etc.), P/M hard materials ( production and characterization, tungsten carbides, titanium carbides, microstructural design, coatings composition and performance, etc.) and general topics. From 37 papers 24 correspond to INIS subject scope and they were indexed separately. (nevyjel)

  18. Powder metallurgical high performance materials. Proceedings. Volume 4: late papers

    International Nuclear Information System (INIS)

    Kneringer, G.; Roedhammer, P.; Wildner, H.

    2001-01-01

    This is the fourth volume (late papers) of the 15th International Plansee seminar 2001 which general theme was 'Powder metallurgical high performance materials'. The seminar looked beyond the refractory metals and cemented carbides, which remain as its focus, to novel classes of materials, such as intermetallic compounds, with potential for high temperature applications. This volume 4 contains papers dealing with high performance P/M metals (ITER and fusion reactors, solid targets, materials microstructure, novel alloys, etc.), P/M hard materials ( production and characterization, tungsten carbides, titanium carbides, microstructural design, coatings composition and performance, etc.) and general topics. From 37 papers 24 correspond to INIS subject scope and they were indexed separately. (nevyjel)

  19. Effective moduli of high volume fraction particulate composites

    International Nuclear Information System (INIS)

    Kwon, P.; Dharan, C.K.H.

    1995-01-01

    Predictions using current micromechanics theories for the effective moduli of particulate-reinforced composites tend to break down at high volume fractions of the reinforcing phase. The predictions are usually well below experimentally measured values of the Young's modulus for volume fractions exceeding about 0.6. In this paper, the concept of contiguity, which is a measure of phase continuity, is applied to Mori-Tanaka micromechanics theory. It is shown that contiguity of the second phase increases with volume fraction, leading eventually to a reversal in the roles of the inclusion and matrix. In powder metallurgy practice, it is well known that at high volume fractions, sintering and consolidation of the reinforcement make it increasingly continuous and more like the matrix phase, while the former matrix tends to become more like the inclusion phase. The concept of contiguity applied to micromechanics theory results in very good agreement between the predicted Young's modulus and experimental data on tungsten carbide particulate-reinforced cobalt

  20. UCLA High Speed, High Volume Laboratory Network for Infectious Diseases

    Science.gov (United States)

    2008-04-01

    of Human Influenza A( H1N2 ) Reassortant Viruses during the 2001–2002 Influenza Season. Journal Infectious Diseases 2002;186:1490–1493...X, Smith CB, Mungall BA, Lindstrom SE, Hall HE, Subbarao K, et al. Intercontinental circulation of human influenza A( H1N2 ) reas- sortant viruses...numerous samples containing highly pathologic avian influenza and other select agents (dual-use). With FY07 (available), FY08 (available) and FY 09

  1. Highly Insulating Windows Volume Purchase Program Final Report

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-04-01

    This report documents the development, execution outcomes and lessons learned of the Highly Insulating Windows Volume Purchase (WVP) Program carried out over a three-year period from 2009 through 2012. The primary goals of the program were met: 1) reduce the incremental cost of highly insulating windows compared to ENERGY STAR windows; and 2) raise the public and potential buyers’ awareness of highly insulating windows and their benefits. A key outcome of the program is that the 2013 ENERGY STAR Most Efficient criteria for primary residential windows were adopted from the technical specifications set forth in the WVP program.

  2. Read-only high accuracy volume holographic optical correlator

    Science.gov (United States)

    Zhao, Tian; Li, Jingming; Cao, Liangcai; He, Qingsheng; Jin, Guofan

    2011-10-01

    A read-only volume holographic correlator (VHC) is proposed. After the recording of all of the correlation database pages by angular multiplexing, a stand-alone read-only high accuracy VHC will be separated from the VHC recording facilities which include the high-power laser and the angular multiplexing system. The stand-alone VHC has its own low power readout laser and very compact and simple structure. Since there are two lasers that are employed for recording and readout, respectively, the optical alignment tolerance of the laser illumination on the SLM is very sensitive. The twodimensional angular tolerance is analyzed based on the theoretical model of the volume holographic correlator. The experimental demonstration of the proposed read-only VHC is introduced and discussed.

  3. High-volume infiltration analgesia in bilateral hip arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Lasse Ø; Otte, Niels Kristian Stahl; Husted, Henrik

    2011-01-01

    bilateral total hip arthroplasty (THA) in a fast-track setting, saline or high-volume (170 mL) ropivacaine (0.2%) with epinephrine (1:100,000) was administered to the wound intraoperatively along with supplementary postoperative injections via an intraarticular epidural catheter. Oral analgesia...... was instituted preoperatively with a multimodal regimen (gabapentin, celecoxib, and acetaminophen). Pain was assessed repeatedly for 48 hours postoperatively, at rest and with 45° hip flexion. Results Pain scores were low and similar between ropivacaine and saline administration. Median hospital stay was 4...... (range 2-7) days. Interpretation Intraoperative high-volume infiltration with 0.2% ropivacaine with repeated intraarticular injections postoperatively may not give a clinically relevant analgesic effect in THA when combined with a multimodal oral analgesic regimen with gabapentin, celecoxib...

  4. Durability properties of high volume fly ash self compacting concretes

    Energy Technology Data Exchange (ETDEWEB)

    P. Dinakar; K.G. Babu; Manu Santhanam [Indian Institute of Technology, Chennai (India). Building Technology Division

    2008-11-15

    This paper presents an experimental study on the durability properties of self compacting concretes (SCCs) with high volume replacements of fly ash. Eight fly ash self compacting concretes of various strength grades were designed at desired fly ash percentages of 0, 10, 30, 50, 70 and 85%, in comparison with five different mixtures of normal vibrated concretes (NCs) at equivalent strength grades. The durability properties were studied through the measurement of permeable voids, water absorption, acid attack and chloride permeation. The results indicated that the SCCs showed higher permeable voids and water absorption than the vibrated normal concretes of the same strength grades. However, in acid attack and chloride diffusion studies the high volume fly ash SCCs had significantly lower weight losses and chloride ion diffusion.

  5. High-volume infiltration analgesia in bilateral hip arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Lasse Ø; Otte, Niels Kristian Stahl; Husted, Henrik

    2011-01-01

    Background and purpose High-volume infiltration analgesia may be effective in postoperative pain management after hip arthroplasty but methodological problems prevent exact interpretation of previous studies. Methods In a randomized, double-blind placebo-controlled trial in 12 patients undergoing...... bilateral total hip arthroplasty (THA) in a fast-track setting, saline or high-volume (170 mL) ropivacaine (0.2%) with epinephrine (1:100,000) was administered to the wound intraoperatively along with supplementary postoperative injections via an intraarticular epidural catheter. Oral analgesia...... was instituted preoperatively with a multimodal regimen (gabapentin, celecoxib, and acetaminophen). Pain was assessed repeatedly for 48 hours postoperatively, at rest and with 45° hip flexion. Results Pain scores were low and similar between ropivacaine and saline administration. Median hospital stay was 4...

  6. High volume tidal or current flow harnessing system

    Energy Technology Data Exchange (ETDEWEB)

    Gorlov, A.M.

    1984-08-07

    Apparatus permitting the utilization of large volumes of water in the harnessing and extracting of a portion of the power generated by the rise and fall of ocean tides, ocean currents, or flowing rivers includes the provision of a dam, and a specialized single cavity chamber of limited size as compared with the water head enclosed by the dam, and an extremely high volume gating system in which all or nearly all of the water between the high and low levels on either side of the dam is cyclically gated through the single chamber from one side of the dam to the other so as to alternately provide positive air pressure and a partial vacuum within the single chamber. In one embodiment, the specialized chamber has a barrier at the bottom which divides the bottom of the chamber in half, large ports at the bottom of the chamber to permit inflow and outflow of high volumes of water, and ganged structures having a higher total area than that of corresponding ports, in which the structures form sluice gates to selectively seal off and open different sets of ports. In another embodiment, a single chamber is used without a barrier. In this embodiment, vertical sluice gates are used which may be activated automatically by pressures acting on the sluice gates as a result of ingested and expelled water.

  7. SCC with high volume of fly ash content

    Directory of Open Access Journals (Sweden)

    Bakhrakh Anton

    2017-01-01

    Full Text Available Self-compacting concrete is a very perspective building material. It provides great benefits during the construction of heavily reinforced buildings. SCC has outstanding properties such as high flowability, dense structure and high strength due to specific quality of aggregates, fillers, their proportion in mix, use of polycarboxylate-based superplasticizers. Main disadvantages of SCC are high price and the difficulty of obtaining a proper mix. Use of fillers, such as fly ash type F, is a way to make SCC cheaper by replacing part of cement. Fly ash also provides some technological and operating advantages. In this paper the influence of high volume (60% from cement fly ash type F on the properties of concrete mixture and hardened concrete is investigated. The result of the work shows the possibility of reduction the cost of SCC using ordinary fillers and high amount of fly ash. The investigated SCC has low speed of hardening (7-day compressive strength at the range of 41.8 MPa and high volume of entrained air content (3.5%.

  8. Verification and validation guidelines for high integrity systems. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Hecht, H.; Hecht, M.; Dinsmore, G.; Hecht, S.; Tang, D. [SoHaR, Inc., Beverly Hills, CA (United States)

    1995-03-01

    High integrity systems include all protective (safety and mitigation) systems for nuclear power plants, and also systems for which comparable reliability requirements exist in other fields, such as in the process industries, in air traffic control, and in patient monitoring and other medical systems. Verification aims at determining that each stage in the software development completely and correctly implements requirements that were established in a preceding phase, while validation determines that the overall performance of a computer system completely and correctly meets system requirements. Volume I of the report reviews existing classifications for high integrity systems and for the types of errors that may be encountered, and makes recommendations for verification and validation procedures, based on assumptions about the environment in which these procedures will be conducted. The final chapter of Volume I deals with a framework for standards in this field. Volume II contains appendices dealing with specific methodologies for system classification, for dependability evaluation, and for two software tools that can automate otherwise very labor intensive verification and validation activities.

  9. Verification and validation guidelines for high integrity systems. Volume 1

    International Nuclear Information System (INIS)

    Hecht, H.; Hecht, M.; Dinsmore, G.; Hecht, S.; Tang, D.

    1995-03-01

    High integrity systems include all protective (safety and mitigation) systems for nuclear power plants, and also systems for which comparable reliability requirements exist in other fields, such as in the process industries, in air traffic control, and in patient monitoring and other medical systems. Verification aims at determining that each stage in the software development completely and correctly implements requirements that were established in a preceding phase, while validation determines that the overall performance of a computer system completely and correctly meets system requirements. Volume I of the report reviews existing classifications for high integrity systems and for the types of errors that may be encountered, and makes recommendations for verification and validation procedures, based on assumptions about the environment in which these procedures will be conducted. The final chapter of Volume I deals with a framework for standards in this field. Volume II contains appendices dealing with specific methodologies for system classification, for dependability evaluation, and for two software tools that can automate otherwise very labor intensive verification and validation activities

  10. Automated high speed volume computed tomography for inline quality control

    International Nuclear Information System (INIS)

    Hanke, R.; Kugel, A.; Troup, P.

    2004-01-01

    Increasing complexity of innovative products as well as growing requirements on quality and reliability call for more detailed knowledge about internal structures of manufactured components rather by 100 % inspection than just by sampling test. A first-step solution, like radioscopic inline inspection machines, equipped with automated data evaluation software, have become state of the art in the production floor during the last years. However, these machines provide just ordinary two-dimensional information and deliver no volume data e.g. to evaluate exact position or shape of detected defects. One way to solve this problem is the application of X-ray computed tomography (CT). Compared to the performance of the first generation medical scanners (scanning times of many hours), today, modern Volume CT machines for industrial applications need about 5 minutes for a full object scan depending on the object size. Of course, this is still too long to introduce this powerful method into the inline production quality control. In order to gain acceptance, the scanning time including subsequent data evaluation must be decreased significantly and adapted to the manufacturing cycle times. This presentation demonstrates the new technical set up, reconstruction results and the methods for high-speed volume data evaluation of a new fully automated high-speed CT scanner with cycle times below one minute for an object size of less than 15 cm. This will directly create new opportunities in design and construction of more complex objects. (author)

  11. Self compacting concrete incorporating high-volumes of fly ash

    Energy Technology Data Exchange (ETDEWEB)

    Bouzoubaa, N. [Natural Resources Canada, Ottawa, ON (Canada). International Centre for Sustainable Development of Cement and Concrete; Lachemi, M. [Ryerson Polytechnic Univ., Toronto, ON (Canada). Dept. of Civil Engineering

    2004-07-01

    Self-compacting concrete (SCC) is now widely used in reinforced concrete structures. Fine materials such as fly ash ensure that the concrete has the necessary properties of high fluidity and cohesiveness. An experimental study was conducted in which 9 SCC mixtures and one control concrete were produced in order to evaluate SCC made with high-volumes of fly ash. The content of the cementitious materials remained constant at 400 kg/cubic metre, but the ratio of water to cementitious material ranged from 0.35 to 0.45. The viscosity and stability of the fresh concrete was determined for self-compacting mixtures of 40, 50 and 60 per cent Class F fly ash. The compressive strength and drying shrinkage were also determined for the hardened concretes. Results showed that the SCCs developed a 28-day compressive strength ranging from 26 to 48 MPa. It was concluded that high-volumes of Class F fly ash could offer the following advantages to an SCC: reduced construction time and labour cost; eliminate the need for vibration; reduce noise pollution; improve the filling capacity of highly congested structural members; and, ensure good structural performance. 19 refs., 8 tabs., 2 figs.

  12. High speed analysis of high pressure combustion in a constant volume cell

    NARCIS (Netherlands)

    Frijters, P.J.M.; Klein-Douwel, R.J.H.; Manski, S.S.; Somers, L.M.T.; Baert, R.S.G.; Dias, V.

    2005-01-01

    A combustion process with N2, O2 and C2H4 as fuel used in an opticallyaccessible, high pressure, high temperature, constant volume cell forresearch on diesel fuel spray formation, is studied. The flame frontspeed Vf,HS is determined using high speed imaging. The pressure traceof the combustion

  13. Unsupervised Learning Through Randomized Algorithms for High-Volume High-Velocity Data (ULTRA-HV).

    Energy Technology Data Exchange (ETDEWEB)

    Pinar, Ali [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Kolda, Tamara G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Carlberg, Kevin Thomas [Wake Forest Univ., Winston-Salem, MA (United States); Ballard, Grey [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mahoney, Michael [Univ. of California, Berkeley, CA (United States)

    2018-01-01

    Through long-term investments in computing, algorithms, facilities, and instrumentation, DOE is an established leader in massive-scale, high-fidelity simulations, as well as science-leading experimentation. In both cases, DOE is generating more data than it can analyze and the problem is intensifying quickly. The need for advanced algorithms that can automatically convert the abundance of data into a wealth of useful information by discovering hidden structures is well recognized. Such efforts however, are hindered by the massive volume of the data and its high velocity. Here, the challenge is developing unsupervised learning methods to discover hidden structure in high-volume, high-velocity data.

  14. A comparative study of self-consolidating concretes incorporating high-volume natural pozzolan or high-volume fly ash

    KAUST Repository

    Celik, Kemal

    2014-09-01

    The purpose of this study is to compare the effects of Portland cement replacement on the strength and durability of self-consolidating concretes (SSC). The two replacement materials used are high-volume natural pozzolan (HVNP), a Saudi Arabian aluminum-silica rich basaltic glass and high-volume Class-F fly ash (HVFAF), from Jim Bridger Power Plant, Wyoming, US. As an extension of the study, limestone filler (LF) is also used to replace Portland cement, alongside HVNP or HVFAF, forming ternary blends. Along with compressive strength tests, non-steady state chloride migration and gas permeability tests were performed, as durability indicators, on SCC specimens. The results were compared to two reference concretes; 100% ordinary Portland cement (OPC) and 85% OPC - 15% LF by mass. The HVNP and HVFAF concrete mixes showed strength and durability results comparable to those of the reference concretes; identifying that both can effectively be used to produce low-cost and environmental friendly SCC. © 2013 Elsevier Ltd. All rights reserved.

  15. A comparative study of self-consolidating concretes incorporating high-volume natural pozzolan or high-volume fly ash

    KAUST Repository

    Celik, Kemal; Meral, Cagla; Mancio, Mauricio; Mehta, P. Kumar; Monteiro, Paulo J.M.

    2014-01-01

    The purpose of this study is to compare the effects of Portland cement replacement on the strength and durability of self-consolidating concretes (SSC). The two replacement materials used are high-volume natural pozzolan (HVNP), a Saudi Arabian aluminum-silica rich basaltic glass and high-volume Class-F fly ash (HVFAF), from Jim Bridger Power Plant, Wyoming, US. As an extension of the study, limestone filler (LF) is also used to replace Portland cement, alongside HVNP or HVFAF, forming ternary blends. Along with compressive strength tests, non-steady state chloride migration and gas permeability tests were performed, as durability indicators, on SCC specimens. The results were compared to two reference concretes; 100% ordinary Portland cement (OPC) and 85% OPC - 15% LF by mass. The HVNP and HVFAF concrete mixes showed strength and durability results comparable to those of the reference concretes; identifying that both can effectively be used to produce low-cost and environmental friendly SCC. © 2013 Elsevier Ltd. All rights reserved.

  16. A high volume, batch mode {sup 129}Xe polarizer

    Energy Technology Data Exchange (ETDEWEB)

    Wojna-Pelczar, Anna, E-mail: anna.wojna.pelczar@mail.muni.cz [Central European Institute of Technology, Masaryk University, Brno (Czech Republic); Formerly: Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków (Poland); Pałasz, Tadeusz [Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków (Poland)

    2017-06-01

    Numerous designs of optical gas polarizers have been proposed, broadening possible applications of the hyperpolarized gases as contrast agents in magnetic resonance imaging. We present a home–made {sup 129}Xe polarizer based on the spin exchange optical pumping method. The polarizer operates under 1 bar of the gas mixture (at the maximum temperature of 160 °C) in a high volume optical cell (5025 cm{sup 3}). Approximately 100 cm{sup 3} of {sup 129}Xe polarized at 1.50±0.37% is produced in a single cycle of polarization. Operation under standard pressure imposes polarization transfer mainly via van der Waals molecules, resulting in the efficient spin exchange between rubidium and {sup 129}Xe atoms. The design, construction and operation of the polarizer are described in details.

  17. An Experimental Study of High Strength-High Volume Fly Ash Concrete for Sustainable Construction Industry

    Science.gov (United States)

    Kate, Gunavant K.; Thakare, Sunil B., Dr.

    2017-08-01

    Concrete is the most widely used building material in the construction of infrastructures such as buildings, bridges, highways, dams, and many other facilities. This paper reports the development, the basic idea, the main properties of high strength-high volume fly ash with application in concrete associated with the development and implementation of Sustainable Properties of High Volume Fly Ash Concrete (HVFAC) Mixtures and Early Age Shrinkage and mechanical properties of concrete for 7,28,56 and 90days. Another alternative to make environment-friendly concrete is the development of high strength-high-volume fly ash concrete which is an synthesized from materials of geological origin or by-product materials such as fly ash which is rich in silicon and aluminum. In this paper 6 concrete mixtures were produced to evaluate the effect of key parameters on the mechanical properties of concrete and its behavior. The study key parameters are; binder material content, cement replacement ratios, and the steel fibers used to High Volume Fly Ash mixtures for increasing performance of concrete.

  18. Effect of high and low ultrafiltration volume during hemodialysis on relative blood volume

    NARCIS (Netherlands)

    Dasselaar, JJ; de Jong, PE; Huisman, RM; Franssen, CFM

    2006-01-01

    Achieving an optimal posthemodialysis hydration status may be difficult because objective criteria for dry weight are lacking. Both relative blood volume changes (Delta RBV) at the end of hemodialysis and Delta RBV normalized for ultrafiltration volume (Delta RBV/UF ratio) have been reported to

  19. High Power Microwave Tubes: Basics and Trends, Volume 2

    Science.gov (United States)

    Kesari, Vishal; Basu, B. N.

    2018-01-01

    Volume 2 of the book begins with chapter 6, in which we have taken up conventional MWTs (such as TWTs, klystrons, including multi-cavity and multi-beam klystrons, klystron variants including reflex klystron, IOT, EIK, EIO and twystron, and crossed-field tubes, namely, magnetron, CFA and carcinotron). In chapter 7, we have taken up fast-wave tubes (such as gyrotron, gyro-BWO, gyro-klystron, gyro-TWT, CARM, SWCA, hybrid gyro-tubes and peniotron). In chapter 8, we discuss vacuum microelectronic tubes (such as klystrino module, THz gyrotron and clinotron BWO); plasma-assisted tubes (such as PWT, plasma-filled TWT, BWO, including PASOTRON, and gyrotron); and HPM (high power microwave) tubes (such as relativistic TWT, relativistic BWO, RELTRON (variant of relativistic klystron), relativistic magnetron, high power Cerenkov tubes including SWO, RDG or orotron, MWCG and MWDG, bremsstrahlung radiation type tube, namely, vircator, and M-type tube MILO). In Chapter 9, we provide handy information about the frequency and power ranges of common MWTs, although more such information is provided at relevant places in the rest of the book as and where necessary. Chapter 10 is an epilogue that sums up the authors' attempt to bring out the various aspects of the basics of and trends in high power MWTs.

  20. Characterization of segmented large volume, high purity germanium detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bruyneel, B. [Koeln Univ. (Germany). Inst. fuer Kernphysik

    2006-07-01

    {gamma}-ray tracking in future HPGe arrays like AGATA will rely on pulse shape analysis (PSA) of multiple {gamma}-interactions. For this purpose, a simple and fast procedure was developed which enabled the first full characterization of a segmented large volume HPGe detector. An analytical model for the hole mobility in a Ge crystal lattice was developed to describe the hole drift anisotropy with experimental velocity values along the crystal axis as parameters. The new model is based on the drifted Maxwellian hole distribution in Ge. It is verified by reproducing successfully experimental longitudinal hole anisotropy data. A comparison between electron and hole mobility shows large differences for the longitudinal and tangential velocity anisotropy as a function of the electrical field orientation. Measurements on a 12 fold segmented, n-type, large volume, irregular shaped HPGe detector were performed in order to determine the parameters of anisotropic mobility for electrons and holes as charge carriers created by {gamma}-ray interactions. To characterize the electron mobility the complete outer detector surface was scanned in small steps employing photopeak interactions at 60 keV. A precise measurement of the hole drift anisotropy was performed with 356 keV rays. The drift velocity anisotropy and crystal geometry cause considerable rise time differences in pulse shapes depending on the position of the spatial charge carrier creation. Pulse shapes of direct and transient signals are reproduced by weighting potential calculations with high precision. The measured angular dependence of rise times is caused by the anisotropic mobility, crystal geometry, changing field strength and space charge effects. Preamplified signals were processed employing digital spectroscopy electronics. Response functions, crosstalk contributions and averaging procedures were taken into account implying novel methods due to the segmentation of the Ge-crystal and the digital electronics

  1. Characterization of segmented large volume, high purity germanium detectors

    International Nuclear Information System (INIS)

    Bruyneel, B.

    2006-01-01

    γ-ray tracking in future HPGe arrays like AGATA will rely on pulse shape analysis (PSA) of multiple γ-interactions. For this purpose, a simple and fast procedure was developed which enabled the first full characterization of a segmented large volume HPGe detector. An analytical model for the hole mobility in a Ge crystal lattice was developed to describe the hole drift anisotropy with experimental velocity values along the crystal axis as parameters. The new model is based on the drifted Maxwellian hole distribution in Ge. It is verified by reproducing successfully experimental longitudinal hole anisotropy data. A comparison between electron and hole mobility shows large differences for the longitudinal and tangential velocity anisotropy as a function of the electrical field orientation. Measurements on a 12 fold segmented, n-type, large volume, irregular shaped HPGe detector were performed in order to determine the parameters of anisotropic mobility for electrons and holes as charge carriers created by γ-ray interactions. To characterize the electron mobility the complete outer detector surface was scanned in small steps employing photopeak interactions at 60 keV. A precise measurement of the hole drift anisotropy was performed with 356 keV rays. The drift velocity anisotropy and crystal geometry cause considerable rise time differences in pulse shapes depending on the position of the spatial charge carrier creation. Pulse shapes of direct and transient signals are reproduced by weighting potential calculations with high precision. The measured angular dependence of rise times is caused by the anisotropic mobility, crystal geometry, changing field strength and space charge effects. Preamplified signals were processed employing digital spectroscopy electronics. Response functions, crosstalk contributions and averaging procedures were taken into account implying novel methods due to the segmentation of the Ge-crystal and the digital electronics. The results are

  2. Ribbon scanning confocal for high-speed high-resolution volume imaging of brain.

    Directory of Open Access Journals (Sweden)

    Alan M Watson

    Full Text Available Whole-brain imaging is becoming a fundamental means of experimental insight; however, achieving subcellular resolution imagery in a reasonable time window has not been possible. We describe the first application of multicolor ribbon scanning confocal methods to collect high-resolution volume images of chemically cleared brains. We demonstrate that ribbon scanning collects images over ten times faster than conventional high speed confocal systems but with equivalent spectral and spatial resolution. Further, using this technology, we reconstruct large volumes of mouse brain infected with encephalitic alphaviruses and demonstrate that regions of the brain with abundant viral replication were inaccessible to vascular perfusion. This reveals that the destruction or collapse of large regions of brain micro vasculature may contribute to the severe disease caused by Venezuelan equine encephalitis virus. Visualization of this fundamental impact of infection would not be possible without sampling at subcellular resolution within large brain volumes.

  3. Low-volume plus ascorbic acid vs high-volume plus simethicone bowel preparation before colonoscopy

    Science.gov (United States)

    Pontone, Stefano; Angelini, Rita; Standoli, Monica; Patrizi, Gregorio; Culasso, Franco; Pontone, Paolo; Redler, Adriano

    2011-01-01

    AIM: To investigate the effectiveness of low-volume plus ascorbic acid [polyethylene glycol plus ascorbic acid (PEG + Asc)] and high-volume plus simethicone [polyethylene glycol plus simethicone (PEG + Sim)] bowel preparations. METHODS: A total of one hundred and forty-four outpatients (76 males), aged from 20 to 84 years (median age 59.5 years), who attended our Department, were divided into two groups, age and sex matched, and underwent colonoscopy. Two questionnaires, one for patients reporting acceptability and the other for endoscopists evaluating bowel cleansing effectiveness according to validated scales, were completed. Indications, timing of examination and endoscopical findings were recorded. Biopsy forceps were used as a measuring tool in order to determine polyp endoscopic size estimation. Difficulty in completing the preparation was rated in a 5-point Likert scale (1 = easy to 5 = unable). Adverse experiences (fullness, cramps, nausea, vomiting, abdominal pain, headache and insomnia), number of evacuations and types of activities performed during preparation (walking or resting in bed) were also investigated. RESULTS: Seventy-two patients were selected for each group. The two groups were age and sex matched as well as being comparable in terms of medical history and drug therapies taken. Fourteen patients dropped out from the trial because they did not complete the preparation procedure. Ratings of global bowel cleansing examinations were considered to be adequate in 91% of PEG + Asc and 88% of PEG + Sim patients. Residual Stool Score indicated similar levels of amount and consistency of residual stool; there was a significant difference in the percentage of bowel wall visualization in favour of PEG + Sim patients. In the PEG + Sim group, 12 adenomas ≤ 10 mm diameter (5/left colon + 7/right colon) vs 9 (8/left colon + 1/right colon) in the PEG + Asc group were diagnosed. Visualization of small lesions seems to be one of the primary advantages of the

  4. Volumizing effects of a smooth, highly cohesive, viscous 20-mg/mL hyaluronic acid volumizing filler: prospective European study

    Directory of Open Access Journals (Sweden)

    Hoffmann Klaus

    2009-08-01

    Full Text Available Abstract Background Facial volume loss contributes significantly to facial aging. The 20-mg/mL hyaluronic acid (HA formulation used in this study is a smooth, highly cohesive, viscous, fully reversible, volumizing filler indicated to restore facial volume. This first prospective study evaluated use in current aesthetic clinical practice. Methods A pan-European evaluation conducted under guidelines of the World Association of Opinion and Marketing Research, the trial comprised a baseline visit (visit 1 and a follow-up (visit 2 at 14 ± 7 days posttreatment. Physicians photographed patients at each visit. Each patient was treated with the 20-mg/mL HA volumizing filler as supplied in standard packaging. Procedural details, aesthetic outcomes, safety, and physician and patient ratings of their experience were recorded. Results Fifteen physicians and 70 patients (91% female; mean age: 50 years participated. Mean volume loss at baseline was 3.7 (moderate on the Facial Volume Loss Scale. Local anesthesia was used in 64.3% of cases. Most injections (85% were administered with needles rather than cannulas. Of the 208 injections, 59% were in the malar region, primarily above the periosteum. Subcutaneous injections were most common for other sites. The mean total injection volume per patient was 4.6 mL. The mean volume loss score declined significantly (P Conclusion The 20-mg/mL smooth, highly cohesive, viscous, volumizing HA filler was effective, well tolerated, and easy to use in current clinical practice. Participants were very likely to recommend this product to colleagues and friends, and patients would be very or quite likely to request this product for future treatments.

  5. EUV source development for high-volume chip manufacturing tools

    Science.gov (United States)

    Stamm, Uwe; Yoshioka, Masaki; Kleinschmidt, Jürgen; Ziener, Christian; Schriever, Guido; Schürmann, Max C.; Hergenhan, Guido; Borisov, Vladimir M.

    2007-03-01

    Xenon-fueled gas discharge produced plasma (DPP) sources were integrated into Micro Exposure Tools already in 2004. Operation of these tools in a research environment gave early learning for the development of EUV sources for Alpha and Beta-Tools. Further experiments with these sources were performed for basic understanding on EUV source technology and limits, especially the achievable power and reliability. The intermediate focus power of Alpha-Tool sources under development is measured to values above 10 W. Debris mitigation schemes were successfully integrated into the sources leading to reasonable collector mirror lifetimes with target of 10 billion pulses due to the effective debris flux reduction. Source collector mirrors, which withstand the radiation and temperature load of Xenon-fueled sources, have been developed in cooperation with MediaLario Technologies to support intermediate focus power well above 10 W. To fulfill the requirements for High Volume chip Manufacturing (HVM) applications, a new concept for HVM EUV sources with higher efficiency has been developed at XTREME technologies. The discharge produced plasma (DPP) source concept combines the use of rotating disk electrodes (RDE) with laser exited droplet targets. The source concept is called laser assisted droplet RDE source. The fuel of these sources has been selected to be Tin. The conversion efficiency achieved with the laser assisted droplet RDE source is 2-3x higher compared to Xenon. Very high pulse energies well above 200 mJ / 2π sr have been measured with first prototypes of the laser assisted droplet RDE source. If it is possible to maintain these high pulse energies at higher repetition rates a 10 kHz EUV source could deliver 2000 W / 2π sr. According to the first experimental data the new concept is expected to be scalable to an intermediate focus power on the 300 W level.

  6. VOLUME BASED DTM GENERATION FROM VERY HIGH RESOLUTION PHOTOGRAMMETRIC DSMS

    Directory of Open Access Journals (Sweden)

    B. Piltz

    2016-06-01

    Full Text Available In this paper we propose a new algorithm for digital terrain (DTM model reconstruction from very high spatial resolution digital surface models (DSMs. It represents a combination of multi-directional filtering with a new metric which we call normalized volume above ground to create an above-ground mask containing buildings and elevated vegetation. This mask can be used to interpolate a ground-only DTM. The presented algorithm works fully automatically, requiring only the processing parameters minimum height and maximum width in metric units. Since slope and breaklines are not decisive criteria, low and smooth and even very extensive flat objects are recognized and masked. The algorithm was developed with the goal to generate the normalized DSM for automatic 3D building reconstruction and works reliably also in environments with distinct hillsides or terrace-shaped terrain where conventional methods would fail. A quantitative comparison with the ISPRS data sets Potsdam and Vaihingen show that 98-99% of all building data points are identified and can be removed, while enough ground data points (~66% are kept to be able to reconstruct the ground surface. Additionally, we discuss the concept of size dependent height thresholds and present an efficient scheme for pyramidal processing of data sets reducing time complexity to linear to the number of pixels, O(WH.

  7. Critical factors for assembling a high volume of DNA barcodes

    Science.gov (United States)

    Hajibabaei, Mehrdad; deWaard, Jeremy R; Ivanova, Natalia V; Ratnasingham, Sujeevan; Dooh, Robert T; Kirk, Stephanie L; Mackie, Paula M; Hebert, Paul D.N

    2005-01-01

    Large-scale DNA barcoding projects are now moving toward activation while the creation of a comprehensive barcode library for eukaryotes will ultimately require the acquisition of some 100 million barcodes. To satisfy this need, analytical facilities must adopt protocols that can support the rapid, cost-effective assembly of barcodes. In this paper we discuss the prospects for establishing high volume DNA barcoding facilities by evaluating key steps in the analytical chain from specimens to barcodes. Alliances with members of the taxonomic community represent the most effective strategy for provisioning the analytical chain with specimens. The optimal protocols for DNA extraction and subsequent PCR amplification of the barcode region depend strongly on their condition, but production targets of 100K barcode records per year are now feasible for facilities working with compliant specimens. The analysis of museum collections is currently challenging, but PCR cocktails that combine polymerases with repair enzyme(s) promise future success. Barcode analysis is already a cost-effective option for species identification in some situations and this will increasingly be the case as reference libraries are assembled and analytical protocols are simplified. PMID:16214753

  8. High accurate volume holographic correlator with 4000 parallel correlation channels

    Science.gov (United States)

    Ni, Kai; Qu, Zongyao; Cao, Liangcai; Su, Ping; He, Qingsheng; Jin, Guofan

    2008-03-01

    Volume holographic correlator allows simultaneously calculate the two-dimensional inner product between the input image and each stored image. We have recently experimentally implemented in VHC 4000 parallel correlation channels with better than 98% output accuracy in a single location in a crystal. The speckle modulation is used to suppress the sidelobes of the correlation patterns, allowing more correlation spots to be contained in the output plane. A modified exposure schedule is designed to ensure the hologram in each channel with unity diffraction efficiency. In this schedule, a restricted coefficient was introduced into the original exposure schedule to solve the problem that the sensitivity and time constant of the crystal will change as a time function when in high-capacity storage. An interleaving method is proposed to improve the output accuracy. By unifying the distribution of the input and stored image patterns without changing the inner products between them, this method could eliminate the impact of correlation pattern variety on calculated inner product values. Moreover, by using this method, the maximum correlation spot size is reduced, which decreases the required minimum safe clearance between neighboring spots in the output plane, allowing more spots to be parallely detected without crosstalk. The experimental results are given and analyzed.

  9. Rheology and setting of high volume fly ash mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Dale P. Bentz; Chiara F. Ferraris [National Institute of Standards and Technology, Gaithersburg, MD (United States). Building and Fire Research Laboratory

    2010-04-15

    While high volume fly ash (HVFA) concretes can be designed and produced to meet 28-d strength requirements and often even exceed the durability performance of conventional concretes, a persistent problem is the potentially long delay in setting time that produces concurrently long delays in finishing the concrete in the field. Previous isothermal calorimetry studies on two different powder additions, namely calcium hydroxide and a rapid set cement, have shown that these powders can mitigate excessive retardation of the hydration reactions. In this paper, rheological measurements and conventional Vicat setting time studies are conducted to verify that these powder additions do indeed reduce setting times in paste systems based on both ASTM Class C and ASTM Class F fly ashes. The reductions depend on the class of fly ash and suggest that trial mixtures would be a necessity to apply these technologies to each specific fly ash/cement/admixture combination being employed in the field. Potentially, for such screening studies, the rheological measurement of yield stress may provide a faster indication of setting (and finishability) than conventional Vicat needle penetration measurements on pastes.

  10. Microstrain evolution during creep of a high volume fraction superalloy

    Energy Technology Data Exchange (ETDEWEB)

    Ma, S. [Materials Department, New Mexico Tech, Socorro, NM 87801 (United States); Brown, D. [Los Alamos National Laboratory, Los Alamos, NM (United States); Bourke, M.A.M. [Los Alamos National Laboratory, Los Alamos, NM (United States); Daymond, M.R. [Rutherford Appleton Laboratory, ISIS Facility, Chilton, Didcot, Oxon OX11 0QX (United Kingdom); Majumdar, B.S. [Materials Department, New Mexico Tech, Socorro, NM 87801 (United States)]. E-mail: majumdar@nmt.edu

    2005-06-15

    The creep of superalloys containing a high volume fraction of {gamma}' phase is significantly influenced by initial misfit and by the evolution of internal stresses. An in situ neutron diffraction technique was used to monitor elastic microstrains in a polycrystalline superalloy, CM247 LC. The misfit was nearly zero at room temperature and it increased to -0.17% at 900 deg. C. These values are rationalized in terms of thermal mismatch using an eigenstrain formulation and a simple formula is derived to relate the thermal mismatch to the misfit strain. During creep at 425 MPa at 900 deg. C, the material exhibited primarily tertiary behavior. For grains with [0 0 1] axis close to the loading direction, the elastic microstrain in the loading direction increased with creep time for the {gamma}' phase, whereas the opposite occurred for the {gamma} phase. These results are explained in terms of constrained deformation in the narrow {gamma} channels and by an interface dislocation buildup. TEM analysis of the crept microstructure provides evidence of the interface dislocation network.

  11. The deflation limb of the pressure-volume relationship in infants during high-frequency ventilation.

    Science.gov (United States)

    Tingay, David G; Mills, John F; Morley, Colin J; Pellicano, Anastasia; Dargaville, Peter A

    2006-02-15

    The importance of applying high-frequency oscillatory ventilation with a high lung volume strategy in infants is well established. Currently, a lack of reliable methods for assessing lung volume limits clinicians' ability to achieve the optimum volume range. To map the pressure-volume relationship of the lung during high-frequency oscillatory ventilation in infants, to determine at what point ventilation is being applied clinically, and to describe the relationship between airway pressure, lung volume, and oxygenation. In 12 infants, a partial inflation limb and the deflation limb of the pressure-volume relationship were mapped using a quasi-static lung volume optimization maneuver. This involved stepwise airway pressure increments to total lung capacity, followed by decrements until the closing pressure of the lung was identified. Lung volume and oxygen saturation were recorded at each airway pressure. Lung volume was measured using respiratory inductive plethysmography. A distinct deflation limb could be mapped in each infant. Overall, oxygenation and lung volume were improved by applying ventilation on the deflation limb. Maximal lung volume and oxygenation occurred on the deflation limb at a mean airway pressure of 3 and 5 cm H(2)O below the airway pressure approximating total lung capacity, respectively. Using current ventilation strategies, all infants were being ventilated near the inflation limb. It is possible to delineate the deflation limb in infants receiving high-frequency oscillatory ventilation; in doing so, greater lung volume and oxygenation can be achieved, often at lower airway pressures.

  12. High brightness diode lasers controlled by volume Bragg gratings

    Science.gov (United States)

    Glebov, Leonid

    2017-02-01

    Volume Bragg gratings (VBGs) recorded in photo-thermo-refractive (PTR) glass are holographic optical elements that are effective spectral and angular filters withstanding high power laser radiation. Reflecting VBGs are narrow-band spectral filters while transmitting VBGs are narrow-band angular filters. The use of these optical elements in external resonators of semiconductor lasers enables extremely resonant feedback that provides dramatic spectral and angular narrowing of laser diodes radiation without significant power and efficiency penalty. Spectral narrowing of laser diodes by reflecting VBGs demonstrated in wide spectral region from near UV to 3 μm. Commercially available VBGs have spectral width ranged from few nanometers to few tens of picometers. Efficient spectral locking was demonstrated for edge emitters (single diodes, bars, modules, and stacks), vertical cavity surface emitting lasers (VCSELs), grating coupled surface emitting lasers (GCSELs), and interband cascade lasers (ICLs). The use of multiplexed VBGs provides multiwavelength emission from a single emitter. Spectrally locked semiconductor lasers demonstrated CW power from milliwatts to a kilowatt. Angular narrowing by transmitting VBGs enables single transverse mode emission from wide aperture diode lasers having resonators with great Fresnel numbers. This feature provides close to diffraction limit divergence along a slow axis of wide stripe edge emitters. Radiation exchange between lasers by means of spatially profiled or multiplexed VBGs enables coherent combining of diode lasers. Sequence of VBGs or multiplexed VBGs enable spectral combining of spectrally narrowed diode lasers or laser modules. Thus the use of VBGs for diode lasers beam control provides dramatic increase of brightness.

  13. High-pressure-assisted synthesis of high-volume ZnGeP2 polycrystalline

    Science.gov (United States)

    Huang, Changbao; Wu, Haixin; Xiao, Ruichun; Chen, Shijing; Ma, Jiaren

    2018-06-01

    The pnictide and chalcogenide semiconductors are promising materials for the applications in the field of photoelectric. High-purity and high-volume polycrystalline required in the real-world applications is hard to be synthesized due to the high vapor pressure of phosphorus and sulfur components at high temperature. A new high-pressure-resisted method was used to investigate the synthesis of the nonlinear-optical semiconductor ZnGeP2. The high-purity ZnGeP2 polycrystalline material of approximately 500 g was synthesized in one run, which enables the preparation of nominally stoichiometric material. Since increasing internal pressure resistance of quartz crucible and reducing the reaction space, the high-pressure-resisted method can be used to rapidly synthesize other pnictide and chalcogenide semiconductors and control the components ratio.

  14. High call volume at poison control centers: identification and implications for communication.

    Science.gov (United States)

    Caravati, E M; Latimer, S; Reblin, M; Bennett, H K W; Cummins, M R; Crouch, B I; Ellington, L

    2012-09-01

    High volume surges in health care are uncommon and unpredictable events. Their impact on health system performance and capacity is difficult to study. To identify time periods that exhibited very busy conditions at a poison control center and to determine whether cases and communication during high volume call periods are different from cases during low volume periods. Call data from a US poison control center over twelve consecutive months was collected via a call logger and an electronic case database (Toxicall®).Variables evaluated for high call volume conditions were: (1) call duration; (2) number of cases; and (3) number of calls per staff member per 30 minute period. Statistical analyses identified peak periods as busier than 99% of all other 30 minute time periods and low volume periods as slower than 70% of all other 30 minute periods. Case and communication characteristics of high volume and low volume calls were compared using logistic regression. A total of 65,364 incoming calls occurred over 12 months. One hundred high call volume and 4885 low call volume 30 minute periods were identified. High volume periods were more common between 1500 and 2300 hours and during the winter months. Coded verbal communication data were evaluated for 42 high volume and 296 low volume calls. The mean (standard deviation) call length of these calls during high volume and low volume periods was 3 minutes 27 seconds (1 minute 46 seconds) and 3 minutes 57 seconds (2 minutes 11 seconds), respectively. Regression analyses revealed a trend for fewer overall verbal statements and fewer staff questions during peak periods, but no other significant differences for staff-caller communication behaviors were found. Peak activity for poison center call volume can be identified by statistical modeling. Calls during high volume periods were similar to low volume calls. Communication was more concise yet staff was able to maintain a good rapport with callers during busy call periods

  15. Electrical Capacitance Volume Tomography with High-Contrast Dielectrics

    Science.gov (United States)

    Nurge, Mark

    2010-01-01

    The Electrical Capacitance Volume Tomography (ECVT) system has been designed to complement the tools created to sense the presence of water in nonconductive spacecraft materials, by helping to not only find the approximate location of moisture but also its quantity and depth. The ECVT system has been created for use with a new image reconstruction algorithm capable of imaging high-contrast dielectric distributions. Rather than relying solely on mutual capacitance readings as is done in traditional electrical capacitance tomography applications, this method reconstructs high-resolution images using only the self-capacitance measurements. The image reconstruction method assumes that the material under inspection consists of a binary dielectric distribution, with either a high relative dielectric value representing the water or a low dielectric value for the background material. By constraining the unknown dielectric material to one of two values, the inverse math problem that must be solved to generate the image is no longer ill-determined. The image resolution becomes limited only by the accuracy and resolution of the measurement circuitry. Images were reconstructed using this method with both synthetic and real data acquired using an aluminum structure inserted at different positions within the sensing region. The cuboid geometry of the system has two parallel planes of 16 conductors arranged in a 4 4 pattern. The electrode geometry consists of parallel planes of copper conductors, connected through custom-built switch electronics, to a commercially available capacitance to digital converter. The figure shows two 4 4 arrays of electrodes milled from square sections of copper-clad circuit-board material and mounted on two pieces of glass-filled plastic backing, which were cut to approximately square shapes, 10 cm on a side. Each electrode is placed on 2.0-cm centers. The parallel arrays were mounted with the electrode arrays approximately 3 cm apart. The open ends

  16. High-Volume Production of Lightweight Multijunction Solar Cells

    Science.gov (United States)

    Youtsey, Christopher

    2015-01-01

    MicroLink Devices, Inc., has transitioned its 6-inch epitaxial lift-off (ELO) solar cell fabrication process into a manufacturing platform capable of sustaining large-volume production. This Phase II project improves the ELO process by reducing cycle time and increasing the yield of large-area devices. In addition, all critical device fabrication processes have transitioned to 6-inch production tool sets designed for volume production. An emphasis on automated cassette-to-cassette and batch processes minimizes operator dependence and cell performance variability. MicroLink Devices established a pilot production line capable of at least 1,500 6-inch wafers per month at greater than 80 percent yield. The company also increased the yield and manufacturability of the 6-inch reclaim process, which is crucial to reducing the cost of the cells.

  17. The effect of chronic erythrocytic polycythemia and high altitude upon plasma and blood volumes.

    Science.gov (United States)

    Burton, R. R.; Smith, A. H.

    1972-01-01

    Comparison of two kinds of physiological chronic erythrocytic polycythemias in order to differentiate the specific effect of erythrocytic polycythemia from the general effects of high altitude upon the plasma volume. The two kinds were produced hormonally in female chickens, at sea level, or by protracted high-altitude exposures. It appears that the vascular system of the body may account for an increase in red blood cell mass either by reduction in plasma volume, or by no change in plasma volume, resulting in differential changes in total blood volumes.

  18. Volume measurement variability in three-dimensional high-frequency ultrasound images of murine liver metastases

    International Nuclear Information System (INIS)

    Wirtzfeld, L A; Graham, K C; Groom, A C; MacDonald, I C; Chambers, A F; Fenster, A; Lacefield, J C

    2006-01-01

    The identification and quantification of tumour volume measurement variability is imperative for proper study design of longitudinal non-invasive imaging of pre-clinical mouse models of cancer. Measurement variability will dictate the minimum detectable volume change, which in turn influences the scheduling of imaging sessions and the interpretation of observed changes in tumour volume. In this paper, variability is quantified for tumour volume measurements from 3D high-frequency ultrasound images of murine liver metastases. Experimental B16F1 liver metastases were analysed in different size ranges including less than 1 mm 3 , 1-4 mm 3 , 4-8 mm 3 and 8-70 mm 3 . The intra- and inter-observer repeatability was high over a large range of tumour volumes, but the coefficients of variation (COV) varied over the volume ranges. The minimum and maximum intra-observer COV were 4% and 14% for the 1-4 mm 3 and 3 tumours, respectively. For tumour volumes measured by segmenting parallel planes, the maximum inter-slice distance that maintained acceptable measurement variability increased from 100 to 600 μm as tumour volume increased. Comparison of free breathing versus ventilated animals demonstrated that respiratory motion did not significantly change the measured volume. These results enable design of more efficient imaging studies by using the measured variability to estimate the time required to observe a significant change in tumour volume

  19. Preferential effects of low volume versus high volume replacement with crystalloid fluid in a hemorrhagic shock model in pigs.

    Science.gov (United States)

    Ponschab, Martin; Schöchl, Herbert; Keibl, Claudia; Fischer, Henrik; Redl, Heinz; Schlimp, Christoph J

    2015-10-06

    Fluid resuscitation is a core stone of hemorrhagic shock therapy, and crystalloid fluids seem to be associated with lower mortality compared to colloids. However, as redistribution starts within minutes, it has been suggested to replace blood loss with a minimum of a three-fold amount of crystalloids. The hypothesis was that in comparison to high volume (HV), a lower crystalloid volume (LV) achieves a favorable coagulation profile and exerts sufficient haemodynamics in the acute phase of resuscitation. In 24 anaesthetized pigs, controlled arterial blood loss of 50 % of the estimated blood volume was either (n = 12) replaced with a LV (one-fold) or a HV (three-fold) volume of a balanced, acetated crystalloid solution at room temperature. Hemodynamic parameters, dilution effects and coagulation profile by standard coagulation tests and thromboelastometry at baseline and after resuscitation were determined in both groups. LV resuscitation increased MAP significantly less compared to the HV, 61 ± 7 vs. 82 ± 14 mmHg (p controlled blood loss, a one fold LV crystalloid replacement strategy is sufficient to adequately raise blood pressure up to a mean arterial pressure >50 mm Hg. The concept of damage control resuscitation (DCR) with permissive hypotension may be better met by using LV as compared to a three fold HV resuscitation strategy. High volume administration of an acetated balanced crystalloid does not lead to hyperchloraemic acidosis, but may negatively influence clinical parameters, such as higher blood pressure, lower body temperature and impaired coagulation parameters, which could potentially increase bleeding after trauma. Replacement of acute blood loss with just an equal amount of an acetated balanced crystalloid appears to be the preferential treatment strategy in the acute phase after controlled bleeding.

  20. Trading volume and the number of trades : a comparative study using high frequency data

    OpenAIRE

    Izzeldin, Marwan

    2007-01-01

    Trading volume and the number of trades are both used as proxies for market activity, with disagreement as to which is the better proxy for market activity. This paper investigates this issue using high frequency data for Cisco and Intel in 1997. A number of econometric methods are used, including GARCH augmented with lagged trading volume and number of trades, tests based on moment restrictions, regression analysis of volatility on volume and trades, normality of returns when standardized by...

  1. Going the Extra Mile: Improved Survival for Pancreatic Cancer Patients Traveling to High-volume Centers.

    Science.gov (United States)

    Lidsky, Michael E; Sun, Zhifei; Nussbaum, Daniel P; Adam, Mohamed A; Speicher, Paul J; Blazer, Dan G

    2017-08-01

    This study compares outcomes following pancreaticoduodenectomy (PD) for patients treated at local, low-volume centers and those traveling to high-volume centers. Although outcomes for PD are superior at high-volume institutions, not all patients live in proximity to major medical centers. Theoretical advantages for undergoing surgery locally exist. The 1998 to 2012 National Cancer Data Base was queried for T1-3N0-1M0 pancreatic adenocarcinoma patients who underwent PD. Travel distances to treatment centers were calculated. Overlaying the upper and lower quartiles of travel distance with institutional volume established short travel/low-volume (ST/LV) and long travel/high-volume (LT/HV) cohorts. Overall survival was evaluated. Of 7086 patients, 773 ST/LV patients traveled ≤6.3 (median 3.2) miles to centers performing ≤3.3 PDs yearly, and 758 LT/HV patients traveled ≥45 (median 97.3) miles to centers performing ≥16 PDs yearly. LT/HV patients had higher stage disease (P travel to a high-volume center remained associated with reduced long-term mortality (hazard ratio 0.75, P travel burden, patients treated at high-volume centers had improved perioperative outcomes, short-term mortality, and overall survival. These data support ongoing efforts to centralize care for patients undergoing PD.

  2. Volume Bragg grating narrowed high-power and highly efficient cladding-pumped Raman fiber laser.

    Science.gov (United States)

    Liu, Jun; Yao, Weichao; Zhao, Chujun; Shen, Deyuan; Fan, Dianyuan

    2014-12-10

    High-power and highly efficient operation of a single-mode cladding-pumped Raman fiber laser with narrow lasing bandwidth is demonstrated. The spectral narrowing was realized by an external cavity containing a volume Bragg grating with a center wavelength of 1658 nm. A maximum output power of 10.4 W at 1658.3 nm with a spectral linewidth (FWHM) of ∼0.1  nm was obtained for the launched pump power of 18.4 W, corresponding to a slope efficiency of 109% with respect to the launched pump power. Lasing characteristics of free-running operation are also evaluated and discussed.

  3. APPHi: Automated Photometry Pipeline for High Cadence Large Volume Data

    Science.gov (United States)

    Sánchez, E.; Castro, J.; Silva, J.; Hernández, J.; Reyes, M.; Hernández, B.; Alvarez, F.; García T.

    2018-04-01

    APPHi (Automated Photometry Pipeline) carries out aperture and differential photometry of TAOS-II project data. It is computationally efficient and can be used also with other astronomical wide-field image data. APPHi works with large volumes of data and handles both FITS and HDF5 formats. Due the large number of stars that the software has to handle in an enormous number of frames, it is optimized to automatically find the best value for parameters to carry out the photometry, such as mask size for aperture, size of window for extraction of a single star, and the number of counts for the threshold for detecting a faint star. Although intended to work with TAOS-II data, APPHi can analyze any set of astronomical images and is a robust and versatile tool to performing stellar aperture and differential photometry.

  4. Case mix-adjusted cost of colectomy at low-, middle-, and high-volume academic centers.

    Science.gov (United States)

    Chang, Alex L; Kim, Young; Ertel, Audrey E; Hoehn, Richard S; Wima, Koffi; Abbott, Daniel E; Shah, Shimul A

    2017-05-01

    Efforts to regionalize surgery based on thresholds in procedure volume may have consequences on the cost of health care delivery. This study aims to delineate the relationship between hospital volume, case mix, and variability in the cost of operative intervention using colectomy as the model. All patients undergoing colectomy (n = 90,583) at 183 academic hospitals from 2009-2012 in The University HealthSystems Consortium Database were studied. Patient and procedure details were used to generate a case mix-adjusted predictive model of total direct costs. Observed to expected costs for each center were evaluated between centers based on overall procedure volume. Patient and procedure characteristics were significantly different between volume tertiles. Observed costs at high-volume centers were less than at middle- and low-volume centers. According to our predictive model, high-volume centers cared for a less expensive case mix than middle- and low-volume centers ($12,786 vs $13,236 and $14,497, P case mix at low-volume centers, which may lead to perceived poor performance at these centers. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Improved Short-Term Outcomes following Orthognathic Surgery Are Associated with High-Volume Centers.

    Science.gov (United States)

    Berlin, Nicholas L; Tuggle, Charles T; Steinbacher, Derek M

    2016-08-01

    Previous studies assessing outcomes following orthognathic surgery rely primarily on single-center/surgeon experience. In addition to issues of generalizability, these studies are limited in evaluating the effect of operative volume on patient outcomes. Orthognathic procedures were identified in the 1999 to 2011 Healthcare Cost and Utilization Project Nationwide Inpatient Sample. Outcomes included occurrence of any in-hospital complication, extended length of stay (>2 days), and increased costs (>$10,784). High-volume hospitals were defined as the 90th percentile of case volume or higher (>31 cases/year). Univariate and multivariate analyses were conducted to identify independent predictors of outcomes. Trend analyses were performed to assess changes in the annual rate of patients treated at high-volume hospitals over the study period. Among 101,692 orthognathic surgery patients, 19.6 percent underwent concurrent ancillary procedures (i.e., genioplasty, rhinoplasty, or septoplasty), and 37.6 percent underwent double-jaw surgery. Fifty-three percent were treated at high-volume hospitals. High-volume hospitals more often performed ancillary procedures (21.4 percent versus 17.4 percent; p surgery (41.3 percent versus 33.4 percent; p orthognathic cases nationwide are performed at a small number of high-volume hospitals. These hospitals discharge patients earlier, perform more complex procedures, and have fewer complications. Risk, III.

  6. In-volume heating using high-power laser diodes

    NARCIS (Netherlands)

    Denisenkov, V.S.; Kiyko, V.V.; Vdovin, G.V.

    2015-01-01

    High-power lasers are useful instruments suitable for applications in various fields; the most common industrial applications include cutting and welding. We propose a new application of high-power laser diodes as in-bulk heating source for food industry. Current heating processes use surface

  7. Proceedings of the 1984 workshop on high-energy excitations in condensed matter. Volume II

    International Nuclear Information System (INIS)

    Silver, R.N.

    1984-12-01

    This volume covers electronic excitations, momentum distributions, high energy photons, and a wrap-up session. Abstracts of individual items from the conference were prepared separately for the data base

  8. Powder metallurgical high performance materials. Proceedings. Volume 3: general topics

    International Nuclear Information System (INIS)

    Kneringer, G.; Roedhammer, P.; Wildner, H.

    2001-01-01

    The proceedings of these seminars form an impressive chronicle of the continued progress in the understanding of refractory metals and cemented carbides and in their manufacture and application. The 15 th Plansee Seminar was convened under the general theme 'Powder Metallurgy High Performance Materials'. Under this broadened perspective the seminar will strive to look beyond the refractory metals and cemented carbides, which remain at its focus, to novel classes of materials, such as intermetallic compounds, with potential for high temperature applications. (boteke)

  9. Functionality and Performance Visualization of the Distributed High Quality Volume Renderer (HVR)

    KAUST Repository

    Shaheen, Sara

    2012-07-01

    Volume rendering systems are designed to provide means to enable scientists and a variety of experts to interactively explore volume data through 3D views of the volume. However, volume rendering techniques are computationally intensive tasks. Moreover, parallel distributed volume rendering systems and multi-threading architectures were suggested as natural solutions to provide an acceptable volume rendering performance for very large volume data sizes, such as Electron Microscopy data (EM). This in turn adds another level of complexity when developing and manipulating volume rendering systems. Given that distributed parallel volume rendering systems are among the most complex systems to develop, trace and debug, it is obvious that traditional debugging tools do not provide enough support. As a consequence, there is a great demand to provide tools that are able to facilitate the manipulation of such systems. This can be achieved by utilizing the power of compute graphics in designing visual representations that reflect how the system works and that visualize the current performance state of the system.The work presented is categorized within the field of software Visualization, where Visualization is used to serve visualizing and understanding various software. In this thesis, a number of visual representations that reflect a number of functionality and performance aspects of the distributed HVR, a high quality volume renderer system that uses various techniques to visualize large volume sizes interactively. This work is provided to visualize different stages of the parallel volume rendering pipeline of HVR. This is along with means of performance analysis through a number of flexible and dynamic visualizations that reflect the current state of the system and enables manipulation of them at runtime. Those visualization are aimed to facilitate debugging, understanding and analyzing the distributed HVR.

  10. Effect of high-volume systematic local infiltration analgesia in Caesarean section

    DEFF Research Database (Denmark)

    Larsen, Klaus Richter; Kristensen, B B; Rasmussen, M A

    2015-01-01

    BACKGROUND: Pain after Caesarean section is often treated with opioids with a risk of side effects. Wound infiltration with local anaesthetics is effective and has few side effects, but volume vs. dose concentration has not been examined. METHODS: Ninety patients scheduled for elective Caesarean...... found concerning time spent in the PACU, to first mobilisation or in number of women with nausea/vomiting (P ≥ 0.05). No complications related to ropivacaine were observed. CONCLUSIONS: Systematic infiltration with a high concentration, low volume compared with low concentration, high volume showed...

  11. Development of alkali activated cements and concrete mixture design with high volumes of red mud

    OpenAIRE

    Krivenko, Pavel; Kovalchuk, Oleksandr; Pasko, Anton; Croymans, Tom; Hutt, Mikael; Lutter, Guillaume; Vandevenne, Niels; Schreurs, Sonja; Schroeyers, Wouter

    2017-01-01

    Dedicated cement compositions were formulated to enable the incorporation of large volume fractions of red mud in alkali activated cements, taking into account the role of the aluminosilicate phase in the processes of hydration and hardening. High volume red mud alkali activated cements were synthesized using a proper combination of red mud, low basic aluminosilicate compounds with a glass phase (blast-furnace slag) and additives selected from high-basic Ca-containing cements with a crystalli...

  12. High-level waste borosilicate glass: A compendium of corrosion characteristics. Volume 2

    International Nuclear Information System (INIS)

    Cunnane, J.C.

    1994-03-01

    The objective of this document is to summarize scientific information pertinent to evaluating the extent to which high-level waste borosilicate glass corrosion and the associated radionuclide release processes are understood for the range of environmental conditions to which waste glass may be exposed in service. Alteration processes occurring within the bulk of the glass (e.g., devitrification and radiation-induced changes) are discussed insofar as they affect glass corrosion.This document is organized into three volumes. Volumes I and II represent a tiered set of information intended for somewhat different audiences. Volume I is intended to provide an overview of waste glass corrosion, and Volume 11 is intended to provide additional experimental details on experimental factors that influence waste glass corrosion. Volume III contains a bibliography of glass corrosion studies, including studies that are not cited in Volumes I and II. Volume I is intended for managers, decision makers, and modelers, the combined set of Volumes I, II, and III is intended for scientists and engineers working in the field of high-level waste

  13. High-level waste borosilicate glass: A compendium of corrosion characteristics. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Cunnane, J.C. [comp.; Bates, J.K.; Bradley, C.R. [Argonne National Lab., IL (United States)] [and others

    1994-03-01

    The objective of this document is to summarize scientific information pertinent to evaluating the extent to which high-level waste borosilicate glass corrosion and the associated radionuclide release processes are understood for the range of environmental conditions to which waste glass may be exposed in service. Alteration processes occurring within the bulk of the glass (e.g., devitrification and radiation-induced changes) are discussed insofar as they affect glass corrosion.This document is organized into three volumes. Volumes I and II represent a tiered set of information intended for somewhat different audiences. Volume I is intended to provide an overview of waste glass corrosion, and Volume 11 is intended to provide additional experimental details on experimental factors that influence waste glass corrosion. Volume III contains a bibliography of glass corrosion studies, including studies that are not cited in Volumes I and II. Volume I is intended for managers, decision makers, and modelers, the combined set of Volumes I, II, and III is intended for scientists and engineers working in the field of high-level waste.

  14. Why choose high volume online post-dilution hemodiafiltration?

    NARCIS (Netherlands)

    Basile, Carlo; Davenport, Andrew; Blankestijn, Peter J.

    The mortality rate of patients on maintenance dialysis remains alarmingly high, at approximately 15–20 % per year. Increasing dialyzer urea clearance has not been shown to improve survival and hence interest has shifted towards convective therapies, such as hemodiafiltration (HDF) which can remove

  15. Evaluation of Additive Manufacturing for High Volume Composite Part Molds

    Energy Technology Data Exchange (ETDEWEB)

    Duty, Chad E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kunc, Vlastimil [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lokitz, Bradley S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Springfield, Robert M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-05-01

    ORNL worked with TruDesign, LLC to develop viable coating solutions to enable the use of large scale 3D printing for both low-temperature and high-temperature composite molds. This project resulted in two commercial products and successfully demonstrated the use of printed molds for autoclave processing for the first time.

  16. Delayed High School Starting Times. Information Capsule. Volume 0908

    Science.gov (United States)

    Blazer, Christie

    2009-01-01

    Educators around the nation are considering pushing high school starting times back until later in the morning, based on evidence suggesting that amount of sleep and circadian rhythms play a part in adolescents' academic performance. While research confirms that adolescents do not get enough sleep and that insufficient sleep can negatively…

  17. Performance enhancement of direct ethanol fuel cell using Nafion composites with high volume fraction of titania

    Science.gov (United States)

    Matos, B. R.; Isidoro, R. A.; Santiago, E. I.; Fonseca, F. C.

    2014-12-01

    The present study reports on the performance enhancement of direct ethanol fuel cell (DEFC) at 130 °C with Nafion-titania composite electrolytes prepared by sol-gel technique and containing high volume fractions of the ceramic phase. It is found that for high volume fractions of titania (>10 vol%) the ethanol uptake of composites is largely reduced while the proton conductivity at high-temperatures is weakly dependent on the titania content. Such tradeoff between alcohol uptake and conductivity resulted in a boost of DEFC performance at high temperatures using Nafion-titania composites with high fraction of the inorganic phase.

  18. MBE growth of VCSELs for high volume applications

    Science.gov (United States)

    Jäger, Roland; Riedl, Michael C.

    2011-05-01

    Mass market applications like laser computer mouse or optical data transmission based on vertical-cavity surface-emitting laser (VCSEL) chips need a high over all yield including epitaxy, processing, dicing, mounting and testing. One yield limitation for VCSEL structures is the emission wavelength variation of the substrate surface area leading to the fraction on laser chips which are below or above the specification limits. For most 850 nm VCSEL products a resonator wavelength variation of ±2 nm is common. This represents an average resonator thickness variation of much less than 1% which is quite challenging to be fulfilled on the entire processed wafer surface area. A high over all yield is demonstrated on MBE grown VCSEL structures.

  19. High Power Microwave Tubes: Basics and Trends, Volume 1

    Science.gov (United States)

    Kesari, Vishal; Basu, B. N.

    2018-01-01

    Our aim in this book is to present a bird's-eye view of microwave tubes (MWTs) which continue to be important despite competitive incursions from solid-state devices (SSDs). We have presented a broad and introductory survey which we hope the readers would be encouraged to read rather than going through lengthier books, and subsequently explore the field of MWTs further in selected areas of relevance to their respective interests. We hope that the present book would motivate newcomers to pursue research in MWTs and apprise them as well as decision makers of the salient features and prospects of as well as the trends of progress in MWTs. The scope of ever expanding applications of MWTs in the high power and high frequency regime will sustain and intensify the research and development in MWTs in coming years.

  20. Volume generation of negative ions in high density hydrogen discharges

    International Nuclear Information System (INIS)

    Hiskes, J.R.; Karo, A.M.

    1983-01-01

    A parametric survey is made of a high-density tandem two-chamber hydrogen negative ion system. The optimum extracted negative ion current densities are sensitive to the atom concentration in the discharge and to the system scale length. For scale lengths ranging from 10 cm to 0.1 cm optimum current densities range from of order 1 to 100 mA cm -2 , respectively

  1. High volume fabrication of laser targets using MEMS techniques

    International Nuclear Information System (INIS)

    Spindloe, C; Tomlinson, S; Green, J; Booth, N.; Tolley, M K; Arthur, G; Hall, F; Potter, R; Kar, S; Higginbotham, A

    2016-01-01

    The latest techniques for the fabrication of high power laser targets, using processes developed for the manufacture of Micro-Electro-Mechanical System (MEMS) devices are discussed. These laser targets are designed to meet the needs of the increased shot numbers that are available in the latest design of laser facilities. Traditionally laser targets have been fabricated using conventional machining or coarse etching processes and have been produced in quantities of 10s to low 100s. Such targets can be used for high complexity experiments such as Inertial Fusion Energy (IFE) studies and can have many complex components that need assembling and characterisation with high precision. Using the techniques that are common to MEMS devices and integrating these with an existing target fabrication capability we are able to manufacture and deliver targets to these systems. It also enables us to manufacture novel targets that have not been possible using other techniques. In addition, developments in the positioning systems that are required to deliver these targets to the laser focus are also required and a system to deliver the target to a focus of an F2 beam at 0.1Hz is discussed. (paper)

  2. High volume improves outcomes: The argument for centralization of rectal cancer surgery.

    Science.gov (United States)

    Aquina, Christopher T; Probst, Christian P; Becerra, Adan Z; Iannuzzi, James C; Kelly, Kristin N; Hensley, Bradley J; Rickles, Aaron S; Noyes, Katia; Fleming, Fergal J; Monson, John R T

    2016-03-01

    Centralization of care to "centers of excellence" in Europe has led to improved oncologic outcomes; however, little is known regarding the impact of nonmandated regionalization of rectal cancer care in the United States. The Statewide Planning and Research Cooperative System (SPARCS) was queried for elective abdominoperineal and low anterior resections for rectal cancer from 2000 to 2011 in New York with the use of International Classification of Diseases, Ninth Revision codes. Surgeon volume and hospital volume were grouped into quartiles, and high-volume surgeons (≥ 10 resections/year) and hospitals (≥ 25 resections/year) were defined as the top quartile of annual caseload of rectal cancer resection and compared with the bottom 3 quartiles during analyses. Bivariate and multilevel regression analyses were performed to assess factors associated with restorative procedures, 30-day mortality, and temporal trends in these endpoints. Among 7,798 rectal cancer resections, the overall rate of no-restorative proctectomy and 30-day mortality decreased by 7.7% and 1.2%, respectively, from 2000 to 2011. In addition, there was a linear increase in the proportion of cases performed by both high-volume surgeons and high-volume hospitals and a decrease in the number of surgeons and hospitals performing rectal cancer surgery. High-volume surgeons at high-volume hospitals were associated independently with both less nonrestorative proctectomies (odds ratio 0.65, 95% confidence interval 0.48-0.89) and mortality (odds ratio 0.43, 95% confidence interval 0.21-0.87) rates. No patterns of significant improvement within the volume strata of the surgeon and hospitals were observed over time. This study suggests that the current trend toward regionalization of rectal cancer care to high-volume surgeons and high-volume centers has led to improved outcomes. These findings have implications regarding the policy of health care delivery in the United States, supporting referral to high-volume

  3. Volume measurement of thalami in normal Chinese Han nationality adults by the high-resolution MRI

    International Nuclear Information System (INIS)

    Ma Shuai; Chen Nan; Guo Yulin

    2012-01-01

    Objective: To measure the volume of thalamus in 1000 healthy Chinese Han nationality adults, and to analyze the relationship between thalamic volume and age, sex, weight and cerebral volume, to provide reliable data for the construction of database of Chinese adults' digital standard brain. Methods: Totally 1000 healthy Chinese adults of Han nationality aged from 18 to 80 years were recruited.They were divided into 5 groups by age: 18-30, 31-40, 41-50, 51-60 and 61-80 years. Each group included 100 males and 100 females. Brain images were obtained on a 1.5 T MR, and the outline of thalami was drawn with Aquariusws software. Then the thalamic volume was calculated automatically. The volumes of left and right thalamus were compared by paired sample t-test. Thalamic volumes of the same side were compared between males and females by independent sample t-test. And thalamic volumes of different age groups were compared by one-way ANOVA. The relationships between thalamic volume and age, sex, weight and cerebral volume were analyzed respectively. Results: The males' standardized volumes of left and right thalamus of healthy Chinese Han nationality adults were (5776 ± 780), (5655 ± 759) mm 3 , and they were (5464 ±573), (5360 ± 542) mm 3 for female. The males' thalamic volume was more than the females' on the same side (t=2.245, 2.200, P<0.01). The left thalamic volumes of various age groups were (6180 ± 534), (6047 ± 562), (5426 ± 471), (5552 ± 526), (4866 ± 552) mm 3 , respectively, while the right thalamic volumes of the 5 groups were (6069 ± 532), (5895 ± 539), (5357 ± 480), (5396 ± 445),(4791 ± 558)mm 3 , respectively. There were statistically significant difference among the 5 groups (F=165.686, 165.235, P<0.01). The left and right thalamic volume were all negatively correlated with age (r=-0.633, -0.645, P<0.05). Conclusions: With high resolution 1.5 T MR scanner,grey matter and white matter can be depicted clearly and the outline

  4. High-volume manufacturing device overlay process control

    Science.gov (United States)

    Lee, Honggoo; Han, Sangjun; Woo, Jaeson; Lee, DongYoung; Song, ChangRock; Heo, Hoyoung; Brinster, Irina; Choi, DongSub; Robinson, John C.

    2017-03-01

    Overlay control based on DI metrology of optical targets has been the primary basis for run-to-run process control for many years. In previous work we described a scenario where optical overlay metrology is performed on metrology targets on a high frequency basis including every lot (or most lots) at DI. SEM based FI metrology is performed ondevice in-die as-etched on an infrequent basis. Hybrid control schemes of this type have been in use for many process nodes. What is new is the relative size of the NZO as compared to the overlay spec, and the need to find more comprehensive solutions to characterize and control the size and variability of NZO at the 1x nm node: sampling, modeling, temporal frequency and control aspects, as well as trade-offs between SEM throughput and accuracy.

  5. Moderator's view: High-volume plasma exchange: pro, con and consensus.

    Science.gov (United States)

    Kaplan, Andre A

    2017-09-01

    I have been asked to comment on the pro and con opinions regarding high-volume plasma exchange. The authors of both positions have provided cogent arguments and a reasonable approach to choosing the exchange volume for any given therapeutic plasma exchange. The major issue of relevance in this discussion is the nature of the toxins targeted for removal. These parameters include molecular weight, the apparent volume of distribution, the degree of protein binding, the biologic and chemical half-life, and the severity and rapidity of its toxicity. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  6. Do high-volume hospitals and surgeons provide better care in urologic oncology?

    Science.gov (United States)

    Eastham, James A

    2009-01-01

    Studies focusing primarily on hospital or surgical volume as a surrogate for surgical experience have found substantial variations in outcomes. Increasing surgical experience has been shown to improve outcomes after multiple procedures, including esophagectomy, pancreatectomy, and primary surgery for colon and breast cancer. More recently, evidence has been presented that surgical volume/experience affects quality of life and cancer control outcomes after urologic oncology procedures. Although most of these data pertain to radical prostatectomy, similar conclusions have been reached for radical cystectomy, retroperitoneal lymph node dissection, and management of renal cell carcinoma. This review highlights data indicating that high-volume surgeons and hospitals provide better care for radical prostatectomy.

  7. Laboratory Investigations on Mechanical Properties of High Volume Fly Ash Concrete and Composite Sections

    OpenAIRE

    Aravindkumar B. Harwalkar; S. S. Awanti

    2013-01-01

    Use of fly ash as a supplementary cementing material in large volumes can bring both technological and economic benefits for concrete industry. In this investigation mix proportions for high volume fly ash concrete were determined at cement replacement levels of 50%, 55%, 60% and 65% with low calcium fly ash. Flexural and compressive strengths of different mixes were measured at ages of 7, 28 and 90 days. Flexural strength of composite section prepared from pavement quali...

  8. Secure data storage by three-dimensional absorbers in highly scattering volume medium

    International Nuclear Information System (INIS)

    Matoba, Osamu; Matsuki, Shinichiro; Nitta, Kouichi

    2008-01-01

    A novel data storage in a volume medium with highly scattering coefficient is proposed for data security application. Three-dimensional absorbers are used as data. These absorbers can not be measured by interferometer when the scattering in a volume medium is strong enough. We present a method to reconstruct three-dimensional absorbers and present numerical results to show the effectiveness of the proposed data storage.

  9. High-Q Fabry–Pérot Micro-Cavities for High-Sensitivity Volume Refractometry

    Directory of Open Access Journals (Sweden)

    Noha Gaber

    2018-01-01

    Full Text Available This work reports a novel structure for a Fabry–Pérot micro cavity that combines the highest reported quality factor for an on-chip Fabry–Pérot resonator that exceeds 9800, and a very high sensitivity for an on-chip volume refractometer based on a Fabry–Pérot cavity that is about 1000 nm/refractive index unit (RIU. The structure consists of two cylindrical Bragg micromirrors that achieve confinement of the Gaussian beam in the plan parallel to the chip substrate, while for the perpendicular plan, external fiber rod lenses (FRLs are placed in the optical path of the input and the output of the cavity. This novel structure overcomes number of the drawbacks presented in previous designs. The analyte is passed between the mirrors, enabling its detection from the resonance peak wavelengths of the transmission spectra. Mixtures of ethanol and deionized (DI-water with different ratios are used as analytes with different refractive indices to exploit the device as a micro-opto-fluidic refractometer. The design criteria are detailed and the modeling is based on Gaussian-optics equations, which depicts a scenario closer to reality than the usually used ray-optics modeling.

  10. High-performance technology for indexing of high volumes of Earth remote sensing data

    Science.gov (United States)

    Strotov, Valery V.; Taganov, Alexander I.; Kolesenkov, Aleksandr N.; Kostrov, Boris V.

    2017-10-01

    The present paper has suggested a technology for search, indexing, cataloging and distribution of aerospace images on the basis of geo-information approach, cluster and spectral analysis. It has considered information and algorithmic support of the system. Functional circuit of the system and structure of the geographical data base have been developed on the basis of the geographical online portal technology. Taking into account heterogeneity of information obtained from various sources it is reasonable to apply a geoinformation platform that allows analyzing space location of objects and territories and executing complex processing of information. Geoinformation platform is based on cartographic fundamentals with the uniform coordinate system, the geographical data base, a set of algorithms and program modules for execution of various tasks. The technology for adding by particular users and companies of images taken by means of professional and amateur devices and also processed by various software tools to the array system has been suggested. Complex usage of visual and instrumental approaches allows significantly expanding an application area of Earth remote sensing data. Development and implementation of new algorithms based on the complex usage of new methods for processing of structured and unstructured data of high volumes will increase periodicity and rate of data updating. The paper has shown that application of original algorithms for search, indexing and cataloging of aerospace images will provide an easy access to information spread by hundreds of suppliers and allow increasing an access rate to aerospace images up to 5 times in comparison with current analogues.

  11. Sampling of high amounts of bioaerosols using a high-volume electrostatic field sampler

    DEFF Research Database (Denmark)

    Madsen, A. M.; Sharma, Anoop Kumar

    2008-01-01

    For studies of the biological effects of bioaerosols, large samples are necessary. To be able to sample enough material and to cover the variations in aerosol content during and between working days, a long sampling time is necessary. Recently, a high-volume transportable electrostatic field...... and 315 mg dust (net recovery of the lyophilized dust) was sampled during a period of 7 days, respectively. The sampling rates of the electrostatic field samplers were between 1.34 and 1.96 mg dust per hour, the value for the Gravikon was between 0.083 and 0.108 mg dust per hour and the values for the GSP...... samplers were between 0.0031 and 0.032 mg dust per hour. The standard deviations of replica samplings and the following microbial analysis using the electrostatic field sampler and GSP samplers were at the same levels. The exposure to dust in the straw storage was 7.7 mg m(-3) when measured...

  12. High-Flux Hemodialysis and High-Volume Hemodiafiltration Improve Serum Calcification Propensity.

    Directory of Open Access Journals (Sweden)

    Marijke Dekker

    Full Text Available Calciprotein particles (CPPs may play an important role in the calcification process. The calcification propensity of serum (T50 is highly predictive of all-cause mortality in chronic kidney disease patients. Whether T50 is therapeutically improvable, by high-flux hemodialysis (HD or hemodiafiltration (HDF, has not been studied yet.We designed a cross-sectional single center study, and included stable prevalent in-center dialysis patients on HD or HDF. Patients were divided into two groups based on dialysis modality, were on a thrice-weekly schedule, had a dialysis vintage of > 3 months and vascular access providing a blood flow rate > 300 ml/min. Calcification propensity of serum was measured by the time of transformation from primary to secondary CPP (T50 test, by time-resolved nephelometry.We included 64 patients, mean convective volume was 21.7L (SD 3.3L. In the pooled analysis, T50 levels increased in both the HD and HDF group with pre- and post-dialysis (mean (SD of 244(64 - 301(57 and 253(55 - 304(61 min respectively (P = 0.43(HD vs. HDF. The mean increase in T50 was 26.29% for HD and 21.97% for HDF patients (P = 0.61 (HD vs. HDF. The delta values (Δ of calcium, phosphate and serum albumin were equal in both groups. Baseline T50 was negatively correlated with phosphate, and positively correlated with serum magnesium and fetuin-A. The ΔT50 was mostly influenced by Δ phosphate (r = -0.342; P = 0.002 HD and r = -0.396; P<0.001 HDF in both groups.HD and HDF patients present with same baseline T50 calcification propensity values pre-dialysis. Calcification propensity is significantly improved during both HD and HDF sessions without significant differences between both modalities.

  13. High initial tidal volumes in emergency department patients at risk for acute respiratory distress syndrome.

    Science.gov (United States)

    Allison, Michael G; Scott, Michael C; Hu, Kami M; Witting, Michael D; Winters, Michael E

    2015-04-01

    Emergency department (ED) patients are at high risk for the acute respiratory distress syndrome (ARDS). Settings only 1 mL/kg above recommended tidal volumes confers harm for these patients. The purpose of this study was to determine whether ED physicians routinely initiate mechanical ventilation with low tidal volumes in patients at risk for ARDS. We retrospectively reviewed the charts of all adult patients who were intubated in an urban, academic ED. The charts were analyzed to identify patients in whom ARDS developed within 48 hours after ED admission. Patients were eligible for inclusion if they had bilateral infiltrates on imaging, had a Pao2/Fio2 ratio less than 300 mm Hg and did not have heart failure contributing to their presentation. The tidal volumes set in the ED were then compared with the recommended tidal volume of 6 mL/kg of predicted body weight. The initial tidal volumes set in the ED were higher than recommended by an average of 80 mL (95% confidence interval, 60-110, P tidal volume ventilation setting. In an academic, tertiary hospital, newly intubated ED patients in whom ARDS developed within 48 hours after intubation were ventilated with tidal volumes that exceeded recommendations by an average of 1.5 mL/kg. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Perioperative mortality in cats and dogs undergoing spay or castration at a high-volume clinic.

    Science.gov (United States)

    Levy, J K; Bard, K M; Tucker, S J; Diskant, P D; Dingman, P A

    2017-06-01

    High volume spay-neuter (spay-castration) clinics have been established to improve population control of cats and dogs to reduce the number of animals admitted to and euthanazed in animal shelters. The rise in the number of spay-neuter clinics in the USA has been accompanied by concern about the quality of animal care provided in high volume facilities, which focus on minimally invasive, time saving techniques, high throughput and simultaneous management of multiple animals under various stages of anesthesia. The aim of this study was to determine perioperative mortality for cats and dogs in a high volume spay-neuter clinic in the USA. Electronic medical records and a written mortality log were used to collect data for 71,557 cats and 42,349 dogs undergoing spay-neuter surgery from 2010 to 2016 at a single high volume clinic in Florida. Perioperative mortality was defined as deaths occurring in the 24h period starting with the administration of the first sedation or anesthetic drugs. Perioperative mortality was reported for 34 cats and four dogs for an overall mortality of 3.3 animals/10,000 surgeries (0.03%). The risk of mortality was more than twice as high for females (0.05%) as for males (0.02%) (P=0.008) and five times as high for cats (0.05%) as for dogs (0.009%) (P=0.0007). High volume spay-neuter surgery was associated with a lower mortality rate than that previously reported in low volume clinics, approaching that achieved in human surgery. This is likely to be due to the young, healthy population of dogs and cats, and the continuous refinement of techniques based on experience and the skills and proficiency of teams that specialize in a limited spectrum of procedures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Communications Strategies on Alcohol and Highway Safety. Volume II. High School Youth. Final Report.

    Science.gov (United States)

    Grey Advertising, Inc., New York, NY.

    The second part of a two-part, two volume study deals with high school youth and identifies target populations and communications strategies for encouraging personal action steps to prevent drunk driving. Data, collected from interviews and questionnaires, are summarized and presented in tabular form. One fourth of high schoolers in a…

  16. EUV mask defect inspection and defect review strategies for EUV pilot line and high volume manufacturing

    Science.gov (United States)

    Chan, Y. David; Rastegar, Abbas; Yun, Henry; Putna, E. Steve; Wurm, Stefan

    2010-04-01

    Reducing mask blank and patterned mask defects is the number one challenge for extreme ultraviolet lithography. If the industry succeeds in reducing mask blank defects at the required rate of 10X every year for the next 2-3 years to meet high volume manufacturing defect requirements, new inspection and review tool capabilities will soon be needed to support this goal. This paper outlines the defect inspection and review tool technical requirements and suggests development plans to achieve pilot line readiness in 2011/12 and high volume manufacturing readiness in 2013. The technical specifications, tooling scenarios, and development plans were produced by a SEMATECH-led technical working group with broad industry participation from material suppliers, tool suppliers, mask houses, integrated device manufacturers, and consortia. The paper summarizes this technical working group's assessment of existing blank and mask inspection/review infrastructure capabilities to support pilot line introduction and outlines infrastructure development requirements and tooling strategies to support high volume manufacturing.

  17. US evaluation of volume brain lesions produced by high-intensity focused US

    International Nuclear Information System (INIS)

    Chua, R.V.; Chua, G.T.; Fry, F.J.; Franklin, T.D.; Wills, E.R.; Hastings, J.S.; Sanghui, N.T.

    1987-01-01

    Eighteen volume brain lesions produced by high-intensity focused US in the right cerebral hemispheres of research canines were evaluated by diagnostic US from immediately after ablation up to 62 days later. Animals were killed and perfused for whole-brain recovery. US evaluation of whole-brain specimens was performed. Histologic analysis of brain sections verified lesion placement, size, and tissue response to US. These sections were compared with US studies for correlation data. Correlation data suggest that US visualization may aid in accurate placement of volume brain lesions and in evaluation of effects of high-intensity focuses US in normal brain

  18. Service expectations from high- and low-volume customers in the alcoholic beverage industry

    Directory of Open Access Journals (Sweden)

    Jacques Beukes

    2013-08-01

    Research purpose: This research study investigated the relationship between the volume a customer buys from an alcoholic beverage supply company and what influence this volume has on their customer service expectations. Motivation for the study: The main purpose of this study was to evaluate what influence the volume an organisation buys from alcoholic beverage suppliers has on their service quality expectations. Research design, approach and method: A non-probability judgement sample method was used, with a sample size of 220 respondents. The questionnaire requested respondents (high- and low-volume to rank their customer service expectations and opinions with reference to Parasuraman’s service delivery dimensions. Ranking was done using a five-point Likert scale. Main findings: The findings of the study indicated that both the high- and low-volume customers felt that alcoholic beverage supply companies had to deliver on all five service delivery dimensions but failed to do so to full satisfaction. Practical and managerial implications: It is recommended that the alcoholic beverage supply companies should address the problem areas identified in this study to avoid defection of customers. Contribution and value add: This may assist alcoholic beverage supply companies to better understand the customers’ demographic profiles. The study also revealed that the satisfaction level experienced by customers in both sections of the study (high- and low-demand, with a considerable gap between expectations and opinions within the empathy dimension.

  19. High Energy Performance Tests of Large Volume LaBr{sub 3}:Ce Detector

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A.; Gondal, M.A.; Khiari, F.Z.; Dastageer, M.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Maslehuddin, M.M. [Center for Engineering Research, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2015-07-01

    High energy prompt gamma ray tests of a large volume cylindrical 100 mm x 100 mm (height x diameter) LaBr{sub 3}:Ce detector were carried out using a portable neutron generator-based Prompt Gamma Neutron Activation Analysis (PGNAA) setup. In this study prompt gamma-rays yield were measured from water samples contaminated with toxic elements such nickel, chromium and mercury compounds with gamma ray energies up to 10 MeV. The experimental yield of prompt gamma-rays from toxic elements were compared with the results of Monte Carlo calculations. In spite of its higher intrinsic background due to its larger volume, an excellent agreement between the experimental and calculated yields of high energy gamma-rays from Ni, Cr and Hg samples has been achieved for the large volume LaBr{sub 3}:Ce detector. (authors)

  20. Low versus high volume of culture medium during embryo transfer: a randomized clinical trial.

    Science.gov (United States)

    Sigalos, George Α; Michalopoulos, Yannis; Kastoras, Athanasios G; Triantafyllidou, Olga; Vlahos, Nikos F

    2018-04-01

    The aim of this prospective randomized control trial was to evaluate if the use of two different volumes (20-25 vs 40-45 μl) of media used for embryo transfer affects the clinical outcomes in fresh in vitro fertilization (IVF) cycles. In total, 236 patients were randomized in two groups, i.e., "low volume" group (n = 118) transferring the embryos with 20-25 μl of medium and "high volume" group (n = 118) transferring the embryos with 40-45 μl of medium. The clinical pregnancy, implantation, and ongoing pregnancy rates were compared between the two groups. No statistically significant differences were observed in clinical pregnancy (46.8 vs 54.3%, p = 0.27), implantation (23.7 vs 27.8%, p = 0.30), and ongoing pregnancy (33.3 vs 40.0%, p = 0.31) rates between low and high volume group, respectively. Higher volume of culture medium to load the embryo into the catheter during embryo transfer does not influence the clinical outcome in fresh IVF cycles. NCT03350646.

  1. A flexible and accurate digital volume correlation method applicable to high-resolution volumetric images

    Science.gov (United States)

    Pan, Bing; Wang, Bo

    2017-10-01

    Digital volume correlation (DVC) is a powerful technique for quantifying interior deformation within solid opaque materials and biological tissues. In the last two decades, great efforts have been made to improve the accuracy and efficiency of the DVC algorithm. However, there is still a lack of a flexible, robust and accurate version that can be efficiently implemented in personal computers with limited RAM. This paper proposes an advanced DVC method that can realize accurate full-field internal deformation measurement applicable to high-resolution volume images with up to billions of voxels. Specifically, a novel layer-wise reliability-guided displacement tracking strategy combined with dynamic data management is presented to guide the DVC computation from slice to slice. The displacements at specified calculation points in each layer are computed using the advanced 3D inverse-compositional Gauss-Newton algorithm with the complete initial guess of the deformation vector accurately predicted from the computed calculation points. Since only limited slices of interest in the reference and deformed volume images rather than the whole volume images are required, the DVC calculation can thus be efficiently implemented on personal computers. The flexibility, accuracy and efficiency of the presented DVC approach are demonstrated by analyzing computer-simulated and experimentally obtained high-resolution volume images.

  2. High-pitch dual-source CT coronary angiography with low volumes of contrast medium

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Knobloch, Gesine; Durmus, Tahir; Hamm, Bernd; Schwenke, Carsten; Huppertz, Alexander

    2014-01-01

    To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). One-hundred consecutive patients (body weight 65-85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/m 2 ) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes (G 30 , 30 mL; G 40 , 40 mL; G 50 , 50 mL; G 60 , 60 mL; G 70 , 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. Mean attenuation for men and women ranged from 345.0 and 399.1 HU in G 30 to 478.2 and 571.8 HU in G 70 . Mean attenuation values were higher in groups with higher CM volumes (P 30 , G 40 , G 50 , G 60 and G 70 were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. (orig.)

  3. High-energy molecular lasers self-controlled volume-discharge lasers and applications

    CERN Document Server

    Apollonov, V V

    2016-01-01

    This book displays the physics and design of high-power molecular lasers. The lasers described are self-controlled volume-discharge lasers. The book explains self-sustained discharge lasers, self-initiated discharge lasers and technical approaches to laser design. Important topics discussed are laser efficiency, laser beam quality and electric field homogeneity. The book contains many new innovative applications.

  4. 76 FR 1067 - Testing of Certain High Production Volume Chemicals; Second Group of Chemicals

    Science.gov (United States)

    2011-01-07

    ... Mfg & NOES (number based criteria based criteria significant chemicals (lbs) industrial of workers... 2070-AD16 Testing of Certain High Production Volume Chemicals; Second Group of Chemicals AGENCY... section 4(a)(1)(B) of the Toxic Substances Control Act (TSCA) to require manufacturers, importers, and...

  5. Operating manual for the High Flux Isotope Reactor. Volume I. Description of the facility

    International Nuclear Information System (INIS)

    1982-09-01

    This volume contains a comprehensive description of the High Flux Isotope Reactor Facility. Its primary purpose is to supplement the detailed operating procedures, providing the reactor operators with background information on the various HFIR systems. The detailed operating procdures are presented in another report

  6. Thermosetting resins with high fractions of free volume and inherently low dielectric constants.

    Science.gov (United States)

    Lin, Liang-Kai; Hu, Chien-Chieh; Su, Wen-Chiung; Liu, Ying-Ling

    2015-08-18

    This work demonstrates a new class of thermosetting resins, based on Meldrum's acid (MA) derivatives, which have high fractions of free volume and inherently low k values of about 2.0 at 1 MHz. Thermal decomposition of the MA groups evolves CO2 and acetone to create air-trapped cavities so as to reduce the dielectric constants.

  7. Operating manual for the High Flux Isotope Reactor. Volume I. Description of the facility

    Energy Technology Data Exchange (ETDEWEB)

    1982-09-01

    This volume contains a comprehensive description of the High Flux Isotope Reactor Facility. Its primary purpose is to supplement the detailed operating procedures, providing the reactor operators with background information on the various HFIR systems. The detailed operating procdures are presented in another report.

  8. Lean Production Control at a High-Variety, Low-Volume Parts Manufacturer

    NARCIS (Netherlands)

    Bokhorst, Jos A. C.; Slomp, Jannes

    2010-01-01

    Eaton Electric General Supplies, a parts manufacturing unit that supplies parts for Eaton's electrical business unit, implemented several lean control elements in its high-variety, low-volume production units. These control elements include a constant work-in-process mechanism to limit and control

  9. A lean production control system for high-variety/low-volume environments : a case study implementation

    NARCIS (Netherlands)

    Slomp, J.; Bokhorst, J.A.C.; Germs, R.

    2009-01-01

    Due to the success of lean manufacturing, many companies are interested in implementing a lean production control system. Lean production control principles include the levelling of production, the use of pull mechanisms and takt time control. These principles have mainly been applied in high volume

  10. Statistical evaluation of the mechanical properties of high-volume class F fly ash concretes

    KAUST Repository

    Yoon, Seyoon; Monteiro, Paulo J.M.; Macphee, Donald E.; Glasser, Fredrik P.; Imbabi, Mohammed Salah-Eldin

    2014-01-01

    the authors experimentally and statistically investigated the effects of mix-design factors on the mechanical properties of high-volume class F fly ash concretes. A total of 240 and 32 samples were produced and tested in the laboratory to measure compressive

  11. High tidal volume decreases adult respiratory distress syndrome, atelectasis, and ventilator days compared with low tidal volume in pediatric burned patients with inhalation injury.

    Science.gov (United States)

    Sousse, Linda E; Herndon, David N; Andersen, Clark R; Ali, Arham; Benjamin, Nicole C; Granchi, Thomas; Suman, Oscar E; Mlcak, Ronald P

    2015-04-01

    Inhalation injury, which is among the causes of acute lung injury and acute respiratory distress syndrome (ARDS), continues to represent a significant source of mortality in burned patients. Inhalation injury often requires mechanical ventilation, but the ideal tidal volume strategy is not clearly defined in burned pediatric patients. The aim of this study was to determine the effects of low and high tidal volume on the number of ventilator days, ventilation pressures, and incidence of atelectasis, pneumonia, and ARDS in pediatric burned patients with inhalation injury within 1 year post burn injury. From 1986 to 2014, inhalation injury was diagnosed by bronchoscopy in pediatric burned patients (n = 932). Patients were divided into 3 groups: unventilated (n = 241), high tidal volume (HTV, 15 ± 3 mL/kg, n = 190), and low tidal volume (LTV, 9 ± 3 mL/kg, n = 501). High tidal volume was associated with significantly decreased ventilator days (p tidal volume significantly decreases ventilator days and the incidence of both atelectasis and ARDS compared with low tidal volume in pediatric burned patients with inhalation injury. Therefore, the use of HTV may interrupt sequences leading to lung injury in our patient population. Copyright © 2015 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  12. High-level waste borosilicate glass: A compendium of corrosion characteristics. Volume 3

    International Nuclear Information System (INIS)

    Cunnane, J.C.

    1994-03-01

    The objective of this document is to summarize scientific information pertinent to evaluating the extent to which high-level waste borosilicate glass corrosion and the associated radionuclide release processes are understood for the range of environmental conditions to which waste glass may be exposed in service. Alteration processes occurring within the bulk of the glass (e.g., devitrification and radiation-induced changes) are discussed insofar as they affect glass corrosion. Volume III contains a bibliography of glass corrosion studies, including studies that are not cited in Volumes I and II

  13. High-level waste borosilicate glass: A compendium of corrosion characteristics. Volume 3

    Energy Technology Data Exchange (ETDEWEB)

    Cunnane, J.C. [comp.; Bates, J.K.; Bradley, C.R. [Argonne National Lab., IL (United States)] [and others

    1994-03-01

    The objective of this document is to summarize scientific information pertinent to evaluating the extent to which high-level waste borosilicate glass corrosion and the associated radionuclide release processes are understood for the range of environmental conditions to which waste glass may be exposed in service. Alteration processes occurring within the bulk of the glass (e.g., devitrification and radiation-induced changes) are discussed insofar as they affect glass corrosion. Volume III contains a bibliography of glass corrosion studies, including studies that are not cited in Volumes I and II.

  14. High-volume intensive training course: a new paradigm for video-assisted thoracoscopic surgery education.

    Science.gov (United States)

    Sihoe, Alan D L; Gonzalez-Rivas, Diego; Yang, Timothy Y; Zhu, Yuming; Jiang, Gening

    2018-03-27

    The emergence of ultra-high-volume centres promises new opportunities for thoracic surgical training. The goal of this study was to investigate the effectiveness of a novel observership course in teaching video-assisted thoracoscopic surgery (VATS) at an ultra-high-volume centre. Two-week courses in VATS at a specialist unit now performing >10 000 major lung resections annually (>50 daily on average) were attended by 230 surgeons from around the world from 2013 to 2016. An online survey preserving responder anonymity was completed by 156 attendees (67.8%). Attendees included 37% from Western Europe, 18% from Eastern Europe and 17% from Latin America. Experience with open thoracic surgery for more than 5 years was reported by 67%, but 79% had less than 5 years of VATS lobectomy experience. During the course, 70% observed over 30 uniportal VATS operations (including 38% observing over 50), and 69% attended an animal wet lab. Although 72% of the responders attended the course less than 12 months ago, the number of ports used (P < 0.001), operation times (P < 0.001) and conversion rates (P < 0.001) reported by the responders were reduced significantly after the course. Improvements in the problem areas of tissue retraction, instrumentation, stapler application and coordination with the assistant during VATS were reported by 56%, 57%, 58% and 53%, respectively. Of those who had attended other VATS courses previously, 87% preferred the training from this high-volume course. High-volume intensive observership training at an ultra-high-volume centre may improve VATS proficiency in a short period of time, and may provide a time-efficient modality for future thoracic surgical training.

  15. Amygdalar, hippocampal, and thalamic volumes in youth at high risk for development of bipolar disorder.

    Science.gov (United States)

    Karchemskiy, Asya; Garrett, Amy; Howe, Meghan; Adleman, Nancy; Simeonova, Diana I; Alegria, Dylan; Reiss, Allan; Chang, Kiki

    2011-12-30

    Children of parents with bipolar disorder (BD), especially those with attention deficit hyperactivity disorder (ADHD) and symptoms of depression or mania, are at significantly high risk for developing BD. As we have previously shown amygdalar reductions in pediatric BD, the current study examined amygdalar volumes in offspring of parents (BD offspring) who have not yet developed a full manic episode. Youth participating in the study included 22 BD offspring and 22 healthy controls of comparable age, gender, handedness, and IQ. Subjects had no history of a manic episode, but met criteria for ADHD and moderate mood symptoms. MRI was performed on a 3T GE scanner, using a 3D volumetric spoiled gradient echo series. Amygdalae were manually traced using BrainImage Java software on positionally normalized brain stacks. Bipolar offspring had similar amygdalar volumes compared to the control group. Exploratory analyses yielded no differences in hippocampal or thalamic volumes. Bipolar offspring do not show decreased amygdalar volume, possibly because these abnormalities occur after more prolonged illness rather than as a preexisting risk factor. Longitudinal studies are needed to determine whether amygdalar volumes change during and after the development of BD. 2011 Elsevier Ireland Ltd. All rights reserved.

  16. Low-load high volume resistance exercise stimulates muscle protein synthesis more than high-load low volume resistance exercise in young men.

    Directory of Open Access Journals (Sweden)

    Nicholas A Burd

    Full Text Available BACKGROUND: We aimed to determine the effect of resistance exercise intensity (%1 repetition maximum-1RM and volume on muscle protein synthesis, anabolic signaling, and myogenic gene expression. METHODOLOGY/PRINCIPAL FINDINGS: Fifteen men (21+/-1 years; BMI=24.1+/-0.8 kg/m2 performed 4 sets of unilateral leg extension exercise at different exercise loads and/or volumes: 90% of repetition maximum (1RM until volitional failure (90FAIL, 30% 1RM work-matched to 90%FAIL (30WM, or 30% 1RM performed until volitional failure (30FAIL. Infusion of [ring-13C6] phenylalanine with biopsies was used to measure rates of mixed (MIX, myofibrillar (MYO, and sarcoplasmic (SARC protein synthesis at rest, and 4 h and 24 h after exercise. Exercise at 30WM induced a significant increase above rest in MIX (121% and MYO (87% protein synthesis at 4 h post-exercise and but at 24 h in the MIX only. The increase in the rate of protein synthesis in MIX and MYO at 4 h post-exercise with 90FAIL and 30FAIL was greater than 30WM, with no difference between these conditions; however, MYO remained elevated (199% above rest at 24 h only in 30FAIL. There was a significant increase in AktSer473 at 24h in all conditions (P=0.023 and mTORSer2448 phosphorylation at 4 h post-exercise (P=0.025. Phosporylation of Erk1/2Tyr202/204, p70S6KThr389, and 4E-BP1Thr37/46 increased significantly (P<0.05 only in the 30FAIL condition at 4 h post-exercise, whereas, 4E-BP1Thr37/46 phosphorylation was greater 24 h after exercise than at rest in both 90FAIL (237% and 30FAIL (312% conditions. Pax7 mRNA expression increased at 24 h post-exercise (P=0.02 regardless of condition. The mRNA expression of MyoD and myogenin were consistently elevated in the 30FAIL condition. CONCLUSIONS/SIGNIFICANCE: These results suggest that low-load high volume resistance exercise is more effective in inducing acute muscle anabolism than high-load low volume or work matched resistance exercise modes.

  17. Analysis of the high water wave volume for the Sava River near Zagreb

    Science.gov (United States)

    Trninic, Dusan

    2010-05-01

    The paper analyses volumes of the Sava River high water waves near Zagreb during the period: 1926-2008 (N = 83 years), which is needed for more efficient control of high and flood waters. The primary Sava flood control structures in the City of Zagreb are dikes built on both riverbanks, and the Odra Relief Canal with lateral spillway upstream from the City of Zagreb. Intensive morphological changes in the greater Sava area near Zagreb, and anthropological and climate variations and changes at the Sava catchment up to the Zagreb area require detailed analysis of the water wave characteristics. In one analysis, maximum annual volumes are calculated for high water waves with constant duration of: 10, 20, 30, 40, 50 and 60 days. Such calculations encompass total quantity of water (basic and surface runoff). The log Pearson III distribution is adapted for this series of maximum annual volumes. Based on the results obtained, the interrelations are established between the wave volume as function of duration and occurrence probability. In addition to the analysis of maximum volumes of constant duration, it is interesting to carry out the analyses of maximum volume in excess of the reference discharge since it is very important for the flood control. To determine the reference discharges, a discharge of specific duration is used from an average discharge duration curve. The adopted reference discharges have durations of 50, 40, 30, 20 and 10%. Like in the previous case, log Pearson III distribution is adapted to the maximum wave data series. For reference discharge Q = 604 m3/s (duration 10%), a linear trend is calculated of maximum annual volumes exceeding the reference discharge for the Sava near Zagreb during the analyzed period. The analysis results show a significant decrease trend. A similar analysis is carried out for the following three reference discharges: regular flood control measures at the Sava near Zagreb, which are proclaimed when the water level is 350 cm

  18. Machine vision for high-precision volume measurement applied to levitated containerless material processing

    International Nuclear Information System (INIS)

    Bradshaw, R.C.; Schmidt, D.P.; Rogers, J.R.; Kelton, K.F.; Hyers, R.W.

    2005-01-01

    By combining the best practices in optical dilatometry with numerical methods, a high-speed and high-precision technique has been developed to measure the volume of levitated, containerlessly processed samples with subpixel resolution. Containerless processing provides the ability to study highly reactive materials without the possibility of contamination affecting thermophysical properties. Levitation is a common technique used to isolate a sample as it is being processed. Noncontact optical measurement of thermophysical properties is very important as traditional measuring methods cannot be used. Modern, digitally recorded images require advanced numerical routines to recover the subpixel locations of sample edges and, in turn, produce high-precision measurements

  19. Protein-bound toxins: added value in their removal with high convective volumes.

    Science.gov (United States)

    Abad, Soraya; Vega, Almudena; Quiroga, Borja; Arroyo, David; Panizo, Nayara; Reque, Javier Eduardo; López-Gómez, Juan Manuel

    Chronic kidney disease is associated with an increased risk of cardiovascular events. In recent years, protein-bound toxins have become more important due to their association with increased morbidity and mortality, characterised by inadequate clearance during dialysis. The purpose of this study is to assess the influence of high convective volumes on postdilution online haemodiafiltration (OL-HDF) on the removal of medium-sized molecules, small molecules and protein-bound molecules. In forty postdilutional OL-HDF sessions, the reduction rates of toxins of different molecular weights were measured in 13 patients, including protein-bound molecules such as p-cresyl sulphate, indoxyl sulphate and homocysteine. Total convective volume was 28.3 (5.1) litres (range 16.3-38.0 litres). Mean reduction rate of protein-bound molecules was 44.4% (15.7%), 48.7% (14.1%) and 58.6% (8.8%) for p-cresyl sulphate, indoxyl sulphate and homocysteine, respectively. Moreover, a statistically significant direct association was found between the reduction rates of all three molecules, the replacement volume and the Kt/V. High convective volumes during postdilution OL-HDF are associated with increased removal of protein-bound uraemic toxins. Copyright © 2016 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  20. ESTIMATION OF STAND HEIGHT AND FOREST VOLUME USING HIGH RESOLUTION STEREO PHOTOGRAPHY AND FOREST TYPE MAP

    Directory of Open Access Journals (Sweden)

    K. M. Kim

    2016-06-01

    Full Text Available Traditional field methods for measuring tree heights are often too costly and time consuming. An alternative remote sensing approach is to measure tree heights from digital stereo photographs which is more practical for forest managers and less expensive than LiDAR or synthetic aperture radar. This work proposes an estimation of stand height and forest volume(m3/ha using normalized digital surface model (nDSM from high resolution stereo photography (25cm resolution and forest type map. The study area was located in Mt. Maehwa model forest in Hong Chun-Gun, South Korea. The forest type map has four attributes such as major species, age class, DBH class and crown density class by stand. Overlapping aerial photos were taken in September 2013 and digital surface model (DSM was created by photogrammetric methods(aerial triangulation, digital image matching. Then, digital terrain model (DTM was created by filtering DSM and subtracted DTM from DSM pixel by pixel, resulting in nDSM which represents object heights (buildings, trees, etc.. Two independent variables from nDSM were used to estimate forest stand volume: crown density (% and stand height (m. First, crown density was calculated using canopy segmentation method considering live crown ratio. Next, stand height was produced by averaging individual tree heights in a stand using Esri’s ArcGIS and the USDA Forest Service’s FUSION software. Finally, stand volume was estimated and mapped using aerial photo stand volume equations by species which have two independent variables, crown density and stand height. South Korea has a historical imagery archive which can show forest change in 40 years of successful forest rehabilitation. For a future study, forest volume change map (1970s–present will be produced using this stand volume estimation method and a historical imagery archive.

  1. Scoping studies to reduce ICPP high-level radioactive waste volumes for final disposal

    International Nuclear Information System (INIS)

    Knecht, D.A.; Berreth, J.R.; Chipman, N.A.; Cole, H.S.; Geczi, L.S.; Kerr, W.B.; Staples, B.A.

    1985-08-01

    This report presents the results of scoping studies carried out to determine the feasibility of the following candidate options to reduce high-level waste volume: (1) low-fluoride, low-volume glass, (2) glass-ceramic and ceramic, (3) Modified Zirflex, (4) inerts removal by neutralization, and (5) modified Fluorinel processes. The results of the scoping studies show that the glass-ceramic/ceramic waste forms and neutralization process with potential HLW volume reductions ranging from 60 to 80% appear feasible, based on laboratory-scale tests. The presently used Fluorinel process modified by reducing HF usage also appears to be feasible and could result in up to a 10% potential volume reduction. If the current process start-up tests verify the practicality, reduced HF usage will be implemented. The low-volume glass and Modified Zirflex processes may also be feasible, based on laboratory tests, but would require significantly more process development and/or modifications and could result in only a 20 to 30% potential volume reduction. Based on these scoping studies, it is recommended that (1) the glass-ceramic/ceramic and neutralization processes be developed further, (2) reduced HF use for the Modified Fluorinel process be implemented as soon as practical and other options reducing chemical usage for criticality control be evaluated, (3) basic development for the glass process be continued as a back-up technology, and (4) laboratory-scale radioactive fuel dissolution testing for the Modified Zirflex process be completed with further process development discontinued unless needed in the future

  2. A Study on the Evaluation of Field Application of High-Fluidity Concrete Containing High Volume Fly Ash

    Directory of Open Access Journals (Sweden)

    Yun-Wang Choi

    2015-01-01

    Full Text Available In the recent concrete industry, high-fluidity concrete is being widely used for the pouring of dense reinforced concrete. Normally, in the case of high-fluidity concrete, it includes high binder contents, so it is necessary to replace part of the cement through admixtures such as fly ash to procure economic feasibility and durability. This study shows the mechanical properties and field applicability of high-fluidity concrete using mass of fly ash as alternative materials of cement. The high-fluidity concrete mixed with 50% fly ash was measured to manufacture concrete that applies low water/binder ratio to measure the mechanical characteristics as compressive strength and elastic modulus. Also, in order to evaluate the field applicability, high-fluidity concrete containing high volume fly ash was evaluated for fluidity, compressive strength, heat of hydration, and drying shrinkage of concrete.

  3. Fetal lung volume measurement by MRI with high-speed imaging systems

    Energy Technology Data Exchange (ETDEWEB)

    Osada, Hisao; Kaku, Kenshi [Chiba Univ. (Japan). Hospital

    2002-08-01

    Although ultrasonography is widely used for fetal morphologic observation, magnetic resonance imaging (MRI) has gained popularity as a new prenatal diagnostic method with recent introduction of high-speed imaging systems. Infants with lung hypoplasia affecting respiratory function require intensive management starting immediately after birth. Therefore, accurate prenatal differential diagnosis and severity evaluation are extremely important for these fetuses. The aim of this study is to measure fetal lung volume using a computer-based, three-dimensional MRI imaging system and to evaluate the possibility of clinical applications of this procedure. A total of 96 fetuses were evaluated, all were morphologically abnormal, and MRI was done for advanced assessment from 24 to 39 weeks gestation. Three-directional views of fetal chest were imaged by Signa Horizon, 1.5 Tesla, version 5.6 (General Electronics) with the following conditions; coil: TORSO coil, sequence: SSFSE (single shot fast spin echo), slice thickness: 5 mm, and imaging speed: 2 seconds/slice. To calculate the lung volume and create three-dimensional image, the lung area in each slice was traced out, then multiplied using computer image processing. Simultaneously, the volumes of all slices were summed to give the volume of each lung. Linear regression analysis and analysis of covariance (ANCOVA) were used for statistical analyses. In all cases, clear images were obtained, and were adequate for three-dimensional evaluation of the fetal lung. Thirty-five fetuses had poor outcomes, such as intrauterine fetal death, neonatal death, and intensive respiratory care. Regression lines of lung volume versus gestational week were calculated for these fetuses with poor outcome and 61 other fetuses with good outcome. ANCOVA, with gestational week as a covariant, revealed a significant intergroup difference in the lung volume (p<0.001). Similarly, regression lines of lung volume versus fetal body weight estimated by

  4. A high volume cost efficient production macrostructuring process. [for silicon solar cell surface treatment

    Science.gov (United States)

    Chitre, S. R.

    1978-01-01

    The paper presents an experimentally developed surface macro-structuring process suitable for high volume production of silicon solar cells. The process lends itself easily to automation for high throughput to meet low-cost solar array goals. The tetrahedron structure observed is 0.5 - 12 micron high. The surface has minimal pitting with virtually no or very few undeveloped areas across the surface. This process has been developed for (100) oriented as cut silicon. Chemi-etched, hydrophobic and lapped surfaces were successfully texturized. A cost analysis as per Samics is presented.

  5. High-pitch dual-source CT coronary angiography with low volumes of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Lembcke, Alexander; Hein, Patrick A.; Knobloch, Gesine; Durmus, Tahir; Hamm, Bernd [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); Schwenke, Carsten [SCO:SSiS - Schwenke Consulting, Berlin (Germany); Huppertz, Alexander [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); ISI - Imaging Science Institute Charite, Berlin (Germany)

    2014-01-15

    To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). One-hundred consecutive patients (body weight 65-85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/m{sup 2}) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes (G{sub 30}, 30 mL; G{sub 40}, 40 mL; G{sub 50}, 50 mL; G{sub 60}, 60 mL; G{sub 70}, 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. Mean attenuation for men and women ranged from 345.0 and 399.1 HU in G{sub 30} to 478.2 and 571.8 HU in G{sub 70}. Mean attenuation values were higher in groups with higher CM volumes (P < 0.0001) and higher in women than in men (P < 0.0001). The proportions of segments with attenuation of at least 300 HU in G{sub 30}, G{sub 40}, G{sub 50}, G{sub 60} and G{sub 70} were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. (orig.)

  6. Back-end interconnection. A generic concept for high volume manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Bosman, J.; Budel, T.; De Kok, C.J.G.M.

    2013-10-15

    The general method to realize series connection in thin film PV modules is monolithical interconnection through a sequence of laser scribes (P1, P2 and P3) and layer depositions. This method however implies that the deposition processes are interrupted several times, an undesirable situation in high volume processing. In order to eliminate this drawback we focus our developments on the so called 'back-end interconnection concept' in which series interconnection takes place AFTER the deposition of the functional layers of the thin film PV device. The process of making a back-end interconnection combines laser scribing, curing, sintering and inkjet processes. These different processes interacts with each other and are investigated in order to create processing strategies that are robust to ensure high volume production. The generic approach created a technology base that can be applied to any thin film PV technology.

  7. Adoption of lean principles in a high-volume molecular diagnostic microbiology laboratory.

    Science.gov (United States)

    Mitchell, P Shawn; Mandrekar, Jayawant N; Yao, Joseph D C

    2014-07-01

    Clinical laboratories are constantly facing challenges to do more with less, enhance quality, improve test turnaround time, and reduce operational expenses. Experience with adopting and applying lean concepts and tools used extensively in the manufacturing industry is described for a high-volume clinical molecular microbiology laboratory, illustrating how operational success and benefits can be achieved. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  8. Novel reprocessing methods with nuclide separation for volume reduction of high level radioactive waste

    International Nuclear Information System (INIS)

    Suzuki, Tatsuya

    2015-01-01

    We have proposed the reprocessing system with nuclide separation processes based on the chromatographic technique in the hydrochloric acid solution system. Our proposing system consists of the dissolution process, the reprocessing process, the MA separation process, and nuclide separation processes. In our proposing processes, the pyridine resin is used as a main separation media. We expect that our proposing will contribute to that volume reduction of high level radioactive waste by combining the transmutation techniques, usage of valuable elements, and so on. (author)

  9. VOLUME STUDY WITH HIGH DENSITY OF PARTICLES BASED ON CONTOUR AND CORRELATION IMAGE ANALYSIS

    Directory of Open Access Journals (Sweden)

    Tatyana Yu. Nikolaeva

    2014-11-01

    Full Text Available The subject of study is the techniques of particle statistics evaluation, in particular, processing methods of particle images obtained by coherent illumination. This paper considers the problem of recognition and statistical accounting for individual images of small scattering particles in an arbitrary section of the volume in case of high concentrations. For automatic recognition of focused particles images, a special algorithm for statistical analysis based on contouring and thresholding was used. By means of the mathematical formalism of the scalar diffraction theory, coherent images of the particles formed by the optical system with high numerical aperture were simulated. Numerical testing of the method proposed for the cases of different concentrations and distributions of particles in the volume was performed. As a result, distributions of density and mass fraction of the particles were obtained, and the efficiency of the method in case of different concentrations of particles was evaluated. At high concentrations, the effect of coherent superposition of the particles from the adjacent planes strengthens, which makes it difficult to recognize images of particles using the algorithm considered in the paper. In this case, we propose to supplement the method with calculating the cross-correlation function of particle images from adjacent segments of the volume, and evaluating the ratio between the height of the correlation peak and the height of the function pedestal in the case of different distribution characters. The method of statistical accounting of particles considered in this paper is of practical importance in the study of volume with particles of different nature, for example, in problems of biology and oceanography. Effective work in the regime of high concentrations expands the limits of applicability of these methods for practically important cases and helps to optimize determination time of the distribution character and

  10. 77 FR 21065 - Certain High Production Volume Chemicals; Test Rule and Significant New Use Rule; Fourth Group of...

    Science.gov (United States)

    2012-04-09

    ... 2070-AJ66 Certain High Production Volume Chemicals; Test Rule and Significant New Use Rule; Fourth... an opportunity to comment on a proposed test rule for 23 high production volume (HPV) chemical... necessary, to prohibit or limit that activity before it occurs. The opportunity to present oral comment was...

  11. A reliable and consistent production technology for high volume compacted graphite iron castings

    Directory of Open Access Journals (Sweden)

    Liu Jincheng

    2014-07-01

    Full Text Available The demands for improved engine performance, fuel economy, durability, and lower emissions provide a continual challenge for engine designers. The use of Compacted Graphite Iron (CGI has been established for successful high volume series production in the passenger vehicle, commercial vehicle and industrial power sectors over the last decade. The increased demand for CGI engine components provides new opportunities for the cast iron foundry industry to establish efficient and robust CGI volume production processes, in China and globally. The production window range for stable CGI is narrow and constantly moving. Therefore, any one step single addition of magnesium alloy and the inoculant cannot ensure a reliable and consistent production process for complicated CGI engine castings. The present paper introduces the SinterCast thermal analysis process control system that provides for the consistent production of CGI with low nodularity and reduced porosity, without risking the formation of flake graphite. The technology is currently being used in high volume Chinese foundry production. The Chinese foundry industry can develop complicated high demand CGI engine castings with the proper process control technology.

  12. The current status of emergency operations at a high-volume cancer center.

    Science.gov (United States)

    Komori, Koji; Kimura, Kenya; Kinoshita, Takashi; Ito, Seiji; Abe, Tetsuya; Senda, Yoshiki; Misawa, Kazunari; Ito, Yuichi; Uemura, Norihisa; Natsume, Seiji; Kawai, Ryosuke; Kawakami, Jiro; Asano, Tomonari; Iwata, Yoshinori; Kurahashi, Shintaro; Tsutsuyama, Masayuki; Shigeyoshi, Itaru; Shimizu, Yasuhiro

    2014-01-01

    This study aimed to assess the pathogenic causes, clinical conditions, surgical procedures, in-hospital mortality, and operative death associated with emergency operations at a high-volume cancer center. Although many reports have described the contents, operative procedures, and prognosis of elective surgeries in high-volume cancer centers, emergency operations have not been studied in sufficient detail. We retrospectively enrolled 28 consecutive patients who underwent emergency surgery. Cases involving operative complications were excluded. The following surgical procedures were performed during emergency operations: closure in 3 cases (10.7%), diversion in 22 cases (78.6%), ileus treatment in 2 cases (7.1%), and hemostasis in 1 case (3.6%). Closure alone was performed only once for peritonitis. Diversion was performed in 17 cases (77.3%) of peritonitis, 4 cases (18.2%) of stenosis of the gastrointestinal tract, and 1 case (4.5%) of bleeding. There was a significant overall difference (P = 0.001). The frequency of emergency operations was very low at a high-volume cancer center. However, the recent shift in treatment approaches toward nonoperative techniques may enhance the status of emergency surgical procedures. The results presented in this study will help prepare for emergency situations and resolve them as quickly and efficiently as possible.

  13. Association Between Treatment at High-Volume Facilities and Improved Overall Survival in Soft Tissue Sarcomas.

    Science.gov (United States)

    Venigalla, Sriram; Nead, Kevin T; Sebro, Ronnie; Guttmann, David M; Sharma, Sonam; Simone, Charles B; Levin, William P; Wilson, Robert J; Weber, Kristy L; Shabason, Jacob E

    2018-03-15

    Soft tissue sarcomas (STS) are rare malignancies that require complex multidisciplinary management. Therefore, facilities with high sarcoma case volume may demonstrate superior outcomes. We hypothesized that STS treatment at high-volume (HV) facilities would be associated with improved overall survival (OS). Patients aged ≥18 years with nonmetastatic STS treated with surgery and radiation therapy at a single facility from 2004 through 2013 were identified from the National Cancer Database. Facilities were dichotomized into HV and low-volume (LV) cohorts based on total case volume over the study period. OS was assessed using multivariable Cox regression with propensity score-matching. Patterns of care were assessed using multivariable logistic regression analysis. Of 9025 total patients, 1578 (17%) and 7447 (83%) were treated at HV and LV facilities, respectively. On multivariable analysis, high educational attainment, larger tumor size, higher grade, and negative surgical margins were statistically significantly associated with treatment at HV facilities; conversely, black race and non-metropolitan residence were negative predictors of treatment at HV facilities. On propensity score-matched multivariable analysis, treatment at HV facilities versus LV facilities was associated with improved OS (hazard ratio, 0.87, 95% confidence interval, 0.80-0.95; P = .001). Older age, lack of insurance, greater comorbidity, larger tumor size, higher tumor grade, and positive surgical margins were associated with statistically significantly worse OS. In this observational cohort study using the National Cancer Database, receipt of surgery and radiation therapy at HV facilities was associated with improved OS in patients with STS. Potential sociodemographic disparities limit access to care at HV facilities for certain populations. Our findings highlight the importance of receipt of care at HV facilities for patients with STS and warrant further study into improving access to

  14. High-throughput high-volume nuclear imaging for preclinical in vivo compound screening§.

    Science.gov (United States)

    Macholl, Sven; Finucane, Ciara M; Hesterman, Jacob; Mather, Stephen J; Pauplis, Rachel; Scully, Deirdre; Sosabowski, Jane K; Jouannot, Erwan

    2017-12-01

    Preclinical single-photon emission computed tomography (SPECT)/CT imaging studies are hampered by low throughput, hence are found typically within small volume feasibility studies. Here, imaging and image analysis procedures are presented that allow profiling of a large volume of radiolabelled compounds within a reasonably short total study time. Particular emphasis was put on quality control (QC) and on fast and unbiased image analysis. 2-3 His-tagged proteins were simultaneously radiolabelled by 99m Tc-tricarbonyl methodology and injected intravenously (20 nmol/kg; 100 MBq; n = 3) into patient-derived xenograft (PDX) mouse models. Whole-body SPECT/CT images of 3 mice simultaneously were acquired 1, 4, and 24 h post-injection, extended to 48 h and/or by 0-2 h dynamic SPECT for pre-selected compounds. Organ uptake was quantified by automated multi-atlas and manual segmentations. Data were plotted automatically, quality controlled and stored on a collaborative image management platform. Ex vivo uptake data were collected semi-automatically and analysis performed as for imaging data. >500 single animal SPECT images were acquired for 25 proteins over 5 weeks, eventually generating >3500 ROI and >1000 items of tissue data. SPECT/CT images clearly visualized uptake in tumour and other tissues even at 48 h post-injection. Intersubject uptake variability was typically 13% (coefficient of variation, COV). Imaging results correlated well with ex vivo data. The large data set of tumour, background and systemic uptake/clearance data from 75 mice for 25 compounds allows identification of compounds of interest. The number of animals required was reduced considerably by longitudinal imaging compared to dissection experiments. All experimental work and analyses were accomplished within 3 months expected to be compatible with drug development programmes. QC along all workflow steps, blinding of the imaging contract research organization to compound properties and

  15. PIEZOELECTRIC WAVEGUIDE SENSOR FOR MEASURING PULSE PRESSURE IN CLOSED LIQUID VOLUMES AT HIGH VOLTAGE ELECTRIC DISCHARGE

    Directory of Open Access Journals (Sweden)

    V. G. Zhekul

    2017-10-01

    Full Text Available Purpose. Investigations of the characteristics of pressure waves presuppose the registration of the total profile of the pressure wave at a given point in space. For these purposes, various types of «pressure to the electrical signal» transmitters (sensors are used. Most of the common sensors are unsuitable for measuring the pulse pressure in a closed water volume at high hydrostatic pressures, in particular to study the effect of a powerful high-voltage pulse discharge on increasing the inflow of minerals and drinking water in wells. The purpose of the work was to develop antijamming piezoelectric waveguide sensor for measuring pulse pressure at a close distance from a high-voltage discharge channel in a closed volume of a liquid. Methodology. We have applied the calibration method as used as a secondary standard, the theory of electrical circuits. Results. We have selected the design and the circuit solution of the waveguide pressure sensor. We have developed a waveguide pulse-pressure sensor DTX-1 with a measuring loop. This sensor makes it possible to study the spectral characteristics of pressure waves of high-voltage pulse discharge in closed volumes of liquid at a hydrostatic pressure of up to 20 MPa and a temperature of up to 80 °C. The sensor can be used to study pressure waves with a maximum amplitude value of up to 150 MPa and duration of up to 80 µs. According to the results of the calibration, the sensitivity of the developed sensor DTX-1 with a measuring loop is 0.0346 V/MPa. Originality. We have further developed the theory of designing the waveguide piezoelectric pulse pressure sensors for measuring the pulse pressure at a close distance from a high-voltage discharge channel in a closed fluid volume by controlling the attenuation of the amplitude of the pressure signal. Practical value. We have developed, created, calibrated, used in scientific research waveguide pressure pulse sensors DTX-1. We propose sensors DTX-1 for sale

  16. High Productivity DRIE solutions for 3D-SiP and MEMS Volume Manufacturing

    International Nuclear Information System (INIS)

    Puech, M; Thevenoud, J M; Launay, N; Arnal, N; Godinat, P; Andrieu, B; Gruffat, J M

    2006-01-01

    Emerging 3D-SiP technologies and high volume MEMS applications require high productivity mass production DRIE systems. The Alcatel DRIE product range has recently been optimised to reach the highest process and hardware production performances. A study based on sub-micron high aspect ratio structures encountered in the most stringent 3D-SiP has been carried out. The optimization of the Bosch process parameters has resulted in ultra high silicon etch rates, with unrivalled uniformity and repeatability leading to excellent process. In parallel, most recent hardware and proprietary design optimization including vacuum pumping lines, process chamber, wafer chucks, pressure control system, gas delivery are discussed. These improvements have been monitored in a mass production environment for a mobile phone application. Field data analysis shows a significant reduction of cost of ownership thanks to increased throughput and much lower running costs. These benefits are now available for all 3D-SiP and high volume MEMS applications. The typical etched patterns include tapered trenches for CMOS imagers, through silicon via holes for die stacking, well controlled profile angle for 3D high precision inertial sensors, and large exposed area features for inkjet printer heads and Silicon microphones

  17. Resistance to Corrosion of Reinforcement of High Volume Fly Ash Concrete

    International Nuclear Information System (INIS)

    Kwon, S. O.; Bae, S. H.; Lee, H. J.; Lee, K. M.; Jung, S. H.

    2014-01-01

    Due to the increasing of interest about the eco-friendly concrete, it is increased to use concretes containing by-products of industry such as fly ash(FA), ground granulated blast furnace slag(GGBFS), silica fume(SF), and etc. Especially, these are well known for improving the resistances to reinforcement corrosion in concrete and decreasing chloride ion penetration. The purpose of this experimental research is to evaluate the resistance against corrosion of reinforcement of high volume fly ash(HVFA) concrete which is replaced with high volume fly ash for cement volume. For this purpose, the concrete test specimens were made for various strength level and replacement ratio of FA, and then the compressive strength and diffusion coefficient for chloride ion of them were measured for 28, 91, and 182 days, respectively. Also, corrosion monitoring by half cell potential method was carried out for the made lollypop concrete test specimens to detect the time of corrosion initiation for reinforcement in concrete. As a result, it was observed from the test results that the compressive strength of HVFA concrete was decreased with increasing replacement ratio of FA but long-term resistances against reinforcement corrosion and chloride ion penetration of that were increased

  18. Is the Distance Worth It? Patients With Rectal Cancer Traveling to High-Volume Centers Experience Improved Outcomes.

    Science.gov (United States)

    Xu, Zhaomin; Becerra, Adan Z; Justiniano, Carla F; Boodry, Courtney I; Aquina, Christopher T; Swanger, Alex A; Temple, Larissa K; Fleming, Fergal J

    2017-12-01

    It is unclear whether traveling long distances to high-volume centers would compensate for travel burden among patients undergoing rectal cancer resection. The purpose of this study was to determine whether operative volume outweighs the advantages of being treated locally by comparing the outcomes of patients with rectal cancer treated at local, low-volume centers versus far, high-volume centers. This was a population-based study. The National Cancer Database was queried for patients with rectal cancer. Patients with stage II or III rectal cancer who underwent surgical resection between 2006 and 2012 were included. The outcomes of interest were margins, lymph node yield, receipt of neoadjuvant chemoradiation, adjuvant chemotherapy, readmission within 30 days, 30-day and 90-day mortality, and 5-year overall survival. A total of 18,605 patients met inclusion criteria; 2067 patients were in the long-distance/high-volume group and 1362 in the short-distance/low-volume group. The median travel distance was 62.6 miles for the long-distance/high-volume group and 2.3 miles for the short-distance/low-volume group. Patients who were younger, white, privately insured, and stage III were more likely to have traveled to a high-volume center. When controlled for patient factors, stage, and hospital factors, patients in the short-distance/low-volume group had lower odds of a lymph node yield ≥12 (OR = 0.51) and neoadjuvant chemoradiation (OR = 0.67) and higher 30-day (OR = 3.38) and 90-day mortality (OR = 2.07) compared with those in the long-distance/high-volume group. The short-distance/low-volume group had a 34% high risk of overall mortality at 5 years compared with the long-distance/high-volume group. We lacked data regarding patient and physician decision making and surgeon-specific factors. Our results indicate that when controlled for patient, tumor, and hospital factors, patients who traveled a long distance to a high-volume center had improved lymph node yield

  19. High intensity and reduced volume training attenuates stress and recovery levels in elite swimmers

    DEFF Research Database (Denmark)

    Elbe, Anne-Marie; Rasmussen, Camilla P; Nielsen, Glen

    2016-01-01

    This study investigated the effect of increased high-intensity interval training (HIT) at the expense of total training volume on the stress and recovery levels of elite swimmers. Forty-one elite swimmers participated in the study and were randomly assigned to either a HIT or a control group (CON....... The Recovery Stress Questionnaire - Sport was used to measure the swimmers' stress and recovery levels. After the 12 week intervention, the general stress level was 16.6% (2.6-30.7%; mean and 95% CI) lower and the general recovery level was 6.5% (0.7-12.4%) higher in HIT compared to the CON, after adjusting...... for baseline values. No significant effects could be observed in sports-specific stress or sports-specific recovery. The results indicate that increasing training intensity and reducing training volume for 12 weeks can reduce general stress and increase general recovery levels in competitive swimmers....

  20. Models for high cell density bioreactors must consider biomass volume fraction: Cell recycle example.

    Science.gov (United States)

    Monbouquette, H G

    1987-06-01

    Intrinsic models, which take into account biomass volume fraction, must be formulated for adequate simulation of high-biomass-density fermentations with cell recycle. Through comparison of corresponding intrinsic and non-intrinsic models in dimensionless form, constraints for non-intrinsic model usage in terms of biokinetic and fermenter operating parameters can be identified a priori. Analysis of a simple product-inhibition model indicates that the non-intrinsic approach is suitable only when the attainable biomass volume fraction in the fermentation broth is less than about 0.10. Inappropriate application of a non-intrinsic model can lead to gross errors in calculated substrate and product concentrations, substrate conversion, and volumetric productivity.

  1. Models for high cell density bioreactors must consider biomass volume fraction: cell recycle example

    Energy Technology Data Exchange (ETDEWEB)

    Monbouquette, H.G.

    1987-06-01

    Intrinsic models, which take into account biomass volume fraction, must be formulated for adequate simulation of high-biomass-density fermentations with cell recycle. Through comparison of corresponding intrinsic and non-intrinsic models in dimensionless form, constraints for non-intrinsic model usage in terms of biokinetic and fermenter operating parameters can be identified a priori. Analysis of a simple product-inhibition model indicates that the non-intrinsic approach is suitable only when the attainable biomass volume fraction in the fermentation broth is less than about 0.10. Inappropriate application of a non-intrinsic model can lead to gross errors in calculated substrate and product concentrations, substrate conversion, and volumetric productivity. (Refs. 14).

  2. Glass Property Data and Models for Estimating High-Level Waste Glass Volume

    Energy Technology Data Exchange (ETDEWEB)

    Vienna, John D.; Fluegel, Alexander; Kim, Dong-Sang; Hrma, Pavel R.

    2009-10-05

    This report describes recent efforts to develop glass property models that can be used to help estimate the volume of high-level waste (HLW) glass that will result from vitrification of Hanford tank waste. The compositions of acceptable and processable HLW glasses need to be optimized to minimize the waste-form volume and, hence, to save cost. A database of properties and associated compositions for simulated waste glasses was collected for developing property-composition models. This database, although not comprehensive, represents a large fraction of data on waste-glass compositions and properties that were available at the time of this report. Glass property-composition models were fit to subsets of the database for several key glass properties. These models apply to a significantly broader composition space than those previously publised. These models should be considered for interim use in calculating properties of Hanford waste glasses.

  3. Damping behavior of polymer composites with high volume fraction of NiMnGa powders

    Science.gov (United States)

    Sun, Xiaogang; Song, Jie; Jiang, Hong; Zhang, Xiaoning; Xie, Chaoying

    2011-03-01

    Polymer composites inserted with high volume fraction (up to 70 Vol%) of NiMnGa powders were fabricated and their damping behavior was investigated by dynamic mechanical analysis. It is found that the polymer matrix has little influence on the transformation temperatures of NiMnGa powders. A damping peak appears for NiMnGa/epoxy resin (EP) composites accompanying with the martensitic transformation or reverse martensitic transformation of NiMnGa powders during cooling or heating. The damping capacity for NiMnGa/EP composites increases linearly with the increase of volume fraction of NiMnGa powders and, decreases dramatically as the test frequency increases. The fracture strain of NiMnGa/EP composites decrease with the increase of NiMnGa powders.

  4. Glass Property Data and Models for Estimating High-Level Waste Glass Volume

    International Nuclear Information System (INIS)

    Vienna, John D.; Fluegel, Alexander; Kim, Dong-Sang; Hrma, Pavel R.

    2009-01-01

    This report describes recent efforts to develop glass property models that can be used to help estimate the volume of high-level waste (HLW) glass that will result from vitrification of Hanford tank waste. The compositions of acceptable and processable HLW glasses need to be optimized to minimize the waste-form volume and, hence, to save cost. A database of properties and associated compositions for simulated waste glasses was collected for developing property-composition models. This database, although not comprehensive, represents a large fraction of data on waste-glass compositions and properties that were available at the time of this report. Glass property-composition models were fit to subsets of the database for several key glass properties. These models apply to a significantly broader composition space than those previously publised. These models should be considered for interim use in calculating properties of Hanford waste glasses.

  5. Statistical evaluation of the mechanical properties of high-volume class F fly ash concretes

    KAUST Repository

    Yoon, Seyoon

    2014-03-01

    High-Volume Fly Ash (HVFA) concretes are seen by many as a feasible solution for sustainable, low embodied carbon construction. At the moment, fly ash is classified as a waste by-product, primarily of thermal power stations. In this paper the authors experimentally and statistically investigated the effects of mix-design factors on the mechanical properties of high-volume class F fly ash concretes. A total of 240 and 32 samples were produced and tested in the laboratory to measure compressive strength and Young\\'s modulus respectively. Applicability of the CEB-FIP (Comite Euro-international du Béton - Fédération Internationale de la Précontrainte) and ACI (American Concrete Institute) Building Model Code (Thomas, 2010; ACI Committee 209, 1982) [1,2] to the experimentally-derived mechanical property data for HVFA concretes was established. Furthermore, using multiple linear regression analysis, Mean Squared Residuals (MSRs) were obtained to determine whether a weight- or volume-based mix proportion is better to predict the mechanical properties of HVFA concrete. The significance levels of the design factors, which indicate how significantly the factors affect the HVFA concrete\\'s mechanical properties, were determined using analysis of variance (ANOVA) tests. The results show that a weight-based mix proportion is a slightly better predictor of mechanical properties than volume-based one. The significance level of fly ash substitution rate was higher than that of w/b ratio initially but reduced over time. © 2014 Elsevier Ltd. All rights reserved.

  6. Minimization of storage and disposal volumes by treatment of liquids by highly selective ion exchangers

    International Nuclear Information System (INIS)

    Tusa, E.; Harjula, R.; Lehto, J.

    2000-01-01

    Novel highly selective inorganic ion exchangers provide new efficient methods for the treatment of nuclear waste liquids. These methods have several advantages compared to conventional technologies such as evaporation, direct solidification or treatment by organic ion exchange resins. Due to high selectivity, the radionuclides can be concentrated to a very small volume even from high-salt effluents. This means that the volume waste will be very small compared to other methods, which brings considerable savings in the cost of intermediate storage and final disposal. Process equipment are highly compact and require little supervision, which brings down the capital and operation costs. The new selective inorganic ion exchangers CsTreat, SrTreat and CoTreat (manufactured by Fortum Engineering Ltd., Finland) have the highest selectivities and processing capacities, exceeding those of zeolites by several orders of magnitude. The materials are now in use in a number of nuclear sites worldwide, including those in the USA, Europe and Japan. Installations include mobile and stationary systems. Considerable experience has been gained in the use of these new materials. Lessons learned, as well as advantages and economic benefits of these highly selective exchangers will be discussed in this paper. (authors)

  7. Comparison of the outcomes for laparoscopic gastrectomy performed by the same surgeon between a low-volume hospital and a high-volume center.

    Science.gov (United States)

    Kim, Min Gyu; Kwon, Sung Joon

    2014-05-01

    The volume-outcome relationship in laparoscopic surgery is controversial. This study was designed to identify differences in laparoscopic gastrectomy outcomes between a low-volume hospital and a high-volume center and to provide guidelines for overcoming the problems associated with a low-volume hospital. From April 2009 to November 2012, one surgeon performed 134 totally laparoscopic distal gastrectomies (TLDGs) at a high-volume center (HVC; ASAN Medical Center) and at a low-volume hospital (LVH; Hanyang University Guri Hospital). All laparoscopically assisted gastrectomies were excluded from this study. During the early period of laparoscopic gastrectomy at the low-volume hospital, TLDG with Roux-en-Y gastrojejunostomy (RYGJ) was performed according to the surgeon's choice. The reconstruction method was classified as gastroduodenostomy (GD) or RYGJ. Early surgical outcomes achieved at the LVH were investigated and compared with those obtained at the HVC. The early surgical outcomes differed significantly between the two hospitals. In particular, the postoperative complication rate for the patients who underwent TLDG RYGJ at the LVH was higher than at the HVC (LVH 15.4 % vs. HVC 0 %; p = 0.037). Furthermore, significant differences were observed in the mean operation time (TLDG GD: LVH 141.0 min vs. HVC 117.4 min, p = 0.001; TLDG RYGJ: LVH 186.3 min vs. HVC 134.6 min, p = 0.009) and length of hospital stay (TLDG GD: LVH 8.1 days vs. HVC 7.2 days, p = 0.044; TLDG RYGJ: LVH 11.5 day vs. HVC 6.8 day, p = 0.009). Although all the operations were performed by one experienced surgeon, the early surgical outcomes differed significantly between the low- and high-volume hospitals. Low-volume hospitals often lack well-trained surgical professionals such as first assistants and scrub nurses. Therefore, the authors recommend that a surgeon who works at an LVH should assess potential personnel shortages and find a solution before operating.

  8. Ageless Aluminum-Cerium-Based Alloys in High-Volume Die Casting for Improved Energy Efficiency

    Science.gov (United States)

    Stromme, Eric T.; Henderson, Hunter B.; Sims, Zachary C.; Kesler, Michael S.; Weiss, David; Ott, Ryan T.; Meng, Fanqiang; Kassoumeh, Sam; Evangelista, James; Begley, Gerald; Rios, Orlando

    2018-04-01

    Strong chemical reactions between Al and Ce lead to the formation of intermetallics with exceptional thermal stability. The rapid formation of intermetallics directly from the liquid phase during solidification of Al-Ce alloys leads to an ultrafine microconstituent structure that effectively strengthens as-cast alloys without further microstructural optimization via thermal processing. Die casting is a high-volume manufacturing technology that accounts for greater than 40% of all cast Al products, whereas Ce is highly overproduced as a waste product of other rare earth element (REE) mining. Reducing heat treatments would stimulate significant improvements in manufacturing energy efficiency, exceeding (megatonnes/year) per large-scale heat-treatment line. In this study, multiple compositions were evaluated with wedge mold castings to test the sensitivity of alloys to the variable solidification rate inherent in high-pressure die casting. Once a suitable composition was determined, it was successfully demonstrated at 800 lbs/h in a 600-ton die caster, after which the as-die cast parts performed similarly to ubiquitous A380 in the same geometry without requiring heat treatment. This work demonstrates the compatibility of Al REE alloys with high-volume die-casting applications with minimal heat treatments.

  9. Ageless Aluminum-Cerium-Based Alloys in High-Volume Die Casting for Improved Energy Efficiency

    Science.gov (United States)

    Stromme, Eric T.; Henderson, Hunter B.; Sims, Zachary C.; Kesler, Michael S.; Weiss, David; Ott, Ryan T.; Meng, Fanqiang; Kassoumeh, Sam; Evangelista, James; Begley, Gerald; Rios, Orlando

    2018-06-01

    Strong chemical reactions between Al and Ce lead to the formation of intermetallics with exceptional thermal stability. The rapid formation of intermetallics directly from the liquid phase during solidification of Al-Ce alloys leads to an ultrafine microconstituent structure that effectively strengthens as-cast alloys without further microstructural optimization via thermal processing. Die casting is a high-volume manufacturing technology that accounts for greater than 40% of all cast Al products, whereas Ce is highly overproduced as a waste product of other rare earth element (REE) mining. Reducing heat treatments would stimulate significant improvements in manufacturing energy efficiency, exceeding (megatonnes/year) per large-scale heat-treatment line. In this study, multiple compositions were evaluated with wedge mold castings to test the sensitivity of alloys to the variable solidification rate inherent in high-pressure die casting. Once a suitable composition was determined, it was successfully demonstrated at 800 lbs/h in a 600-ton die caster, after which the as-die cast parts performed similarly to ubiquitous A380 in the same geometry without requiring heat treatment. This work demonstrates the compatibility of Al REE alloys with high-volume die-casting applications with minimal heat treatments.

  10. Porosity of Self-Compacting Concrete (SCC) incorporating high volume fly ash

    Science.gov (United States)

    Kristiawan, S. A.; Sunarmasto; Murti, G. Y.

    2017-02-01

    Degradation of concrete could be triggered by the presence of aggressive agents from the environment into the body of concrete. The penetration of these agents is influenced by the pore characteristics of the concrete. Incorporating a pozzolanic material such as fly ash could modify the pore characteristic of the concrete. This research aims to investigate the influence of incorporating fly ash at high volume level on the porosity of Self-Compacting Concrete (SCC). Laboratory investigations were carried out following the ASTM C642 for measuring density and volume of permeable pores (voids) of the SCC with varying fly ash contents (50-70% by weight of total binder). In addition, a measurement of permeable voids by saturation method was carried out to obtain an additional volume of voids that could not be measured by the immersion and boiling method of ASTM C642. The results show that the influence of fly ash content on the porosity appears to be dependent on age of SCC. At age less than 56 d, fly ash tends to cause an increase of voids but at 90 d of age it reduces the pores. The additional pores that can be penetrated by vacuum saturation method counts about 50% of the total voids.

  11. High Center Volume Does Not Mitigate Risk Associated with Using High Donor Risk Organs in Liver Transplantation.

    Science.gov (United States)

    Beal, Eliza W; Black, Sylvester M; Mumtaz, Khalid; Hayes, Don; El-Hinnawi, Ashraf; Washburn, Kenneth; Tumin, Dmitry

    2017-09-01

    High-risk donor allografts increase access to liver transplant, but potentially reduce patient and graft survival. It is unclear whether the risk associated with using marginal donor livers is mitigated by increasing center experience. The United Network for Organ Sharing registry was queried for adult first-time liver transplant recipients between 2/2002 and 12/2015. High donor risk was defined as donor risk index >1.9, and 1-year patient and graft survival were compared according to donor risk index in small and large centers. Multivariable Cox regression estimated the hazard ratio (HR) associated with using high-risk donor organs, according to a continuous measure of annual center volume. The analysis included 51,770 patients. In 67 small and 67 large centers, high donor risk index predicted increased mortality (p = 0.001). In multivariable analysis, high-donor risk index allografts predicted greater mortality hazard at centers performing 20 liver transplants per year (HR 1.35; 95% CI 1.22, 1.49; p donor risk index and center volume was not statistically significant (p = 0.747), confirming that the risk associated with using marginal donor livers was comparable between smaller and larger centers. Results were consistent when examining graft loss. At both small and large centers, high-risk donor allografts were associated with reduced patient and graft survival after liver transplant. Specific strategies to mitigate the risk of liver transplant involving high-risk donors are needed, in addition to accumulation of center expertise.

  12. Pore volume is most highly correlated with the visual assessment of skin pores.

    Science.gov (United States)

    Kim, S J; Shin, M K; Back, J H; Koh, J S

    2014-11-01

    Many studies have been focused on evaluating assessment techniques for facial pores amid growing attention on skin care. Ubiquitous techniques used to assess the size of facial pores include visual assessment, cross-section images of the skin surface, and profilometric analysis of silicone replica of the facial skin. In addition, there are indirect assessment methods, including observation of pores based on confocal laser scanning microscopy and the analysis of sebum secretion and skin elasticity. The aim of this study was to identify parameters useful in estimating pore of surface in normal skin. The severity of pores on the cheek area by frontal optical images was divided on a 0-6 scale with '0' being faint and small pore and '6' being obvious and large pore. After the photos of the frontal cheek of 32 women aged between 35 and 49 were taken, the size of their pores was measured on a 0-6 scale; and the correlation between visual grading of pore and various evaluations (pore volume by 3-D image, pore area and number by Optical Image Analyzer) contributing to pore severity investigated using direct, objective, and noninvasive evaluations. The visual score revealed that the size of pores was graded on a 1-6 scale. Visual grading of pore was highly correlated with pore volume measured from 3-D images and pore area measured from 2-D optical images in the order (P pore was also slightly correlated with the number of pores in size of over 0.04 mm(2) (P pore score and pore volume can be explained by 3-D structural characteristics of pores. It is concluded that pore volume and area serve as useful parameters in estimating pore of skin surface. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Dose volume assessment of high dose rate 192IR endobronchial implants

    International Nuclear Information System (INIS)

    Cheng, B. Saw; Korb, Leroy J.; Pawlicki, Todd; Wu, Andrew

    1996-01-01

    Purpose: To study the dose distributions of high dose rate (HDR) endobronchial implants using the dose nonuniformity ratio (DNR) and three volumetric irradiation indices. Methods and Materials: Multiple implants were configured by allowing a single HDR 192 Ir source to step through a length of 6 cm along an endobronchial catheter. Dwell times were computed to deliver a dose of 5 Gy to points 1 cm away from the catheter axis. Five sets of source configurations, each with different dwell position spacings from 0.5 to 3.0 cm, were evaluated. Three-dimensional (3D) dose distributions were then generated for each source configuration. Differential and cumulative dose-volume curves were generated to quantify the degree of target volume coverage, dose nonuniformity within the target volume, and irradiation of tissues outside the target volume. Evaluation of the implants were made using the DNR and three volumetric irradiation indices. Results: The observed isodose distributions were not able to satisfy all the dose constraints. The ability to optimally satisfy the dose constraints depended on the choice of dwell position spacing and the specification of the dose constraint points. The DNR and irradiation indices suggest that small dwell position spacing does not result in a more homogeneous dose distribution for the implant. This study supports the existence of a relationship between the dwell position spacing and the distance from the catheter axis to the reference dose or dose constraint points. Better dose homogeneity for an implant can be obtained if the spacing of the dwell positions are about twice the distance from the catheter axis to the reference dose or dose constraint points

  14. High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 5

    International Nuclear Information System (INIS)

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Identification Document (S/RID) is contained in multiple volumes. This document (Volume 5) outlines the standards and requirements for the Fire Protection and Packaging and Transportation sections

  15. High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 4

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Identification Document (S/RID) is contained in multiple volumes. This document (Volume 4) presents the standards and requirements for the following sections: Radiation Protection and Operations.

  16. High level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 6

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Identification Document (S/RID) is contained in multiple volumes. This document (Volume 6) outlines the standards and requirements for the sections on: Environmental Restoration and Waste Management, Research and Development and Experimental Activities, and Nuclear Safety.

  17. High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Document (S/RID) is contained in multiple volumes. This document (Volume 2) presents the standards and requirements for the following sections: Quality Assurance, Training and Qualification, Emergency Planning and Preparedness, and Construction.

  18. High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 2

    International Nuclear Information System (INIS)

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Document (S/RID) is contained in multiple volumes. This document (Volume 2) presents the standards and requirements for the following sections: Quality Assurance, Training and Qualification, Emergency Planning and Preparedness, and Construction

  19. High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 4

    International Nuclear Information System (INIS)

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Identification Document (S/RID) is contained in multiple volumes. This document (Volume 4) presents the standards and requirements for the following sections: Radiation Protection and Operations

  20. High level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 6

    International Nuclear Information System (INIS)

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Identification Document (S/RID) is contained in multiple volumes. This document (Volume 6) outlines the standards and requirements for the sections on: Environmental Restoration and Waste Management, Research and Development and Experimental Activities, and Nuclear Safety

  1. Best Practices During Hip Arthroscopy: Aggregate Recommendations of High-Volume Surgeons.

    Science.gov (United States)

    Gupta, Asheesh; Suarez-Ahedo, Carlos; Redmond, John M; Gerhardt, Michael B; Hanypsiak, Bryan; Stake, Christine E; Finch, Nathan A; Domb, Benjamin G

    2015-09-01

    To survey surgeons who perform a high volume of hip arthroscopy procedures regarding their operative technique, type of procedure, and postoperative management. We conducted a cross-sectional survey of 27 high-volume orthopaedic surgeons specializing in hip arthroscopy to report their preferences and practices related to their operative practice and postoperative rehabilitation protocol. All participants completed the survey in person in an anonymous fashion during a meeting of the American Hip Institute. All surgeons perform hip arthroscopy with the patient in the supine position, accessing the central compartment of the hip initially, using intraoperative fluoroscopy. All surgeons perform labral repair (100%), with the majority performing labral reconstructions (77.8%) and gluteus medius repairs (81.5%). There is variability in the type of anchors used during labral repair. Most surgeons perform capsular closure in most cases (88.9%), inject either intra-articular cortisone or platelet-rich plasma at the conclusion of the procedure (59%), and prescribe a postoperative hip brace for some or all patients (59%). There is considerable variability in rehabilitation protocols. All surgeons routinely prescribe postoperative heterotopic ossification prophylaxis to their patients, with most surgeons (88.9%) prescribing a nonsteroidal anti-inflammatory medication for 3 weeks. Forty percent of the respondents use the modified Harris Hip Score as the most important outcome measure. Consistent practices such as use of intraoperative fluoroscopy, heterotopic ossification prophylaxis, and labral repair skills were identified by surveying 27 hip arthroscopy surgeons at high-volume centers. Most of the surgeons performed routine capsular closure unless underlying conditions precluded capsular release or plication. The survey identified higher variability between surgeons regarding postoperative rehabilitation protocols and use of intra-articular pharmacologic injections at the

  2. Powder metallurgical high performance materials. Proceedings. Volume 1: high performance P/M metals

    International Nuclear Information System (INIS)

    Kneringer, G.; Roedhammer, P.; Wildner, H.

    2001-01-01

    The proceedings of this sequence of seminars form an impressive chronicle of the continued progress in the understanding of refractory metals and cemented carbides and in their manufacture and application. There the ingenuity and assiduous work of thousands of scientists and engineers striving for progress in the field of powder metallurgy is documented in more than 2000 contributions covering some 30000 pages. The 15th Plansee Seminar was convened under the general theme 'Powder Metallurgical High Performance Materials'. Under this broadened perspective the seminar will strive to look beyond the refractory metals and cemented carbides, which remain at its focus, to novel classes of materials, such as intermetallic compounds, with potential for high temperature applications. (author)

  3. Powder metallurgical high performance materials. Proceedings. Volume 1: high performance P/M metals

    Energy Technology Data Exchange (ETDEWEB)

    Kneringer, G; Roedhammer, P; Wildner, H [eds.

    2001-07-01

    The proceedings of this sequence of seminars form an impressive chronicle of the continued progress in the understanding of refractory metals and cemented carbides and in their manufacture and application. There the ingenuity and assiduous work of thousands of scientists and engineers striving for progress in the field of powder metallurgy is documented in more than 2000 contributions covering some 30000 pages. The 15th Plansee Seminar was convened under the general theme 'Powder Metallurgical High Performance Materials'. Under this broadened perspective the seminar will strive to look beyond the refractory metals and cemented carbides, which remain at its focus, to novel classes of materials, such as intermetallic compounds, with potential for high temperature applications. (author)

  4. High-Efficiency Volume Reflection of an Ultrarelativistic Proton Beam with a Bent Silicon Crystal

    CERN Document Server

    Scandale, Walter; Carnera, Alberto; Della Mea, Gianantonio; De Salvador, Davide; Milan, Riccardo; Vomiero, Alberto; Baricordi, Stefano; Dalpiaz, Pietro; Fiorini, Massimiliano; Guidi, Vincenzo; Martinelli,Giuliano; Mazzolari, Andrea; Milan, Emiliano; Ambrosi, Giovanni; Azzarello, Philipp; Battiston, Roberto; Bertucci, Bruna; Burger, William J; Ionica, Maria; Zuccon, Paolo; Cavoto, Gianluca; Santacesaria, Roberta; Valente, Paolo; Vallazza, Erik; Afonin, Alexander G; Baranov, Vladimir T; Chesnokov, Yury A; Kotov, Vladilen I; Maisheev, Vladimir A; Yaznin, Igor A; Afansiev, Sergey V; Kovalenko, Alexander D; Taratin, Alexander M; Denisov, Alexander S; Gavrikov, Yury A; Ivanov, Yuri M; Ivochkin, Vladimir G; Kosyanenko, Sergey V; Petrunin, Anatoli A; Skorobogatov, Vyacheslav V; Suvorov, Vsevolod M; Bolognini, Davide; Foggetta,Luca; Hasan, Said; Prest, Michela

    2007-01-01

    The volume reflection phenomenon was detected while investigating 400 GeV proton interactions with bent silicon crystals in the external beam H8 of the CERN Super Proton Synchrotron. Such a process was observed for a wide interval of crystal orientations relative to the beam axis, and its efficiency exceeds 95%, thereby surpassing any previously observed value. These observations suggest new perspectives for the manipulation of high-energy beams, e.g., for collimation and extraction in new-generation hadron colliders, such as the CERN Large Hadron Collider.

  5. Severe Leptospirosis with Multiple Organ Failure Successfully Treated by Plasma Exchange and High-Volume Hemofiltration

    Directory of Open Access Journals (Sweden)

    Vincent Bourquin

    2011-01-01

    Full Text Available Background. Leptospirosis is a spirochetal zoonosis with complex clinical features including renal and liver failure. Case report. We report the case of a Swiss fisherman presenting with leptospirosis. After initial improvement, refractory septic shock and severe liver and kidney failure developed. The expected mortality was estimated at 90% with clinical scores. The patient underwent plasma exchanges and high-volume hemofiltration (HVHF with complete recovery of hepatic and kidney functions. Discussion. Plasma exchanges and HVHF may confer survival benefit on patients with severe leptospirosis, refractory septic shock, and multiple-organ failure.

  6. A hybrid plasmonic microresonator with high quality factor and small mode volume

    International Nuclear Information System (INIS)

    Lu, Qijing; Chen, Daru; Wu, Genzhu; Peng, Baojin; Xu, Jiancheng

    2012-01-01

    We propose a novel hybrid plasmonic microcavity which is composed of a silver nanoring and a silica toroidal microcavity. The hybrid mode of the proposed hybrid plasmonic microcavity due to the coupling between the surface plasmon polaritons (SPPs) and the dielectric mode is demonstrated with a high quality factor (>1000) and an ultrasmall mode volume (∼0.8 μm 3 ). This microcavity shows great potential in fundamental studies of nonlinear optics and cavity quantum electrodynamics (cQED) and applications in low-threshold plasmonic microlasers. (paper)

  7. Snow cover volumes dynamic monitoring during melting season using high topographic accuracy approach for a Lebanese high plateau witness sinkhole

    Science.gov (United States)

    Abou Chakra, Charbel; Somma, Janine; Elali, Taha; Drapeau, Laurent

    2017-04-01

    Climate change and its negative impact on water resource is well described. For countries like Lebanon, undergoing major population's rise and already decreasing precipitations issues, effective water resources management is crucial. Their continuous and systematic monitoring overs long period of time is therefore an important activity to investigate drought risk scenarios for the Lebanese territory. Snow cover on Lebanese mountains is the most important water resources reserve. Consequently, systematic observation of snow cover dynamic plays a major role in order to support hydrologic research with accurate data on snow cover volumes over the melting season. For the last 20 years few studies have been conducted for Lebanese snow cover. They were focusing on estimating the snow cover surface using remote sensing and terrestrial measurement without obtaining accurate maps for the sampled locations. Indeed, estimations of both snow cover area and volumes are difficult due to snow accumulation very high variability and Lebanese mountains chains slopes topographic heterogeneity. Therefore, the snow cover relief measurement in its three-dimensional aspect and its Digital Elevation Model computation is essential to estimate snow cover volume. Despite the need to cover the all lebanese territory, we favored experimental terrestrial topographic site approaches due to high resolution satellite imagery cost, its limited accessibility and its acquisition restrictions. It is also most challenging to modelise snow cover at national scale. We therefore, selected a representative witness sinkhole located at Ouyoun el Siman to undertake systematic and continuous observations based on topographic approach using a total station. After four years of continuous observations, we acknowledged the relation between snow melt rate, date of total melting and neighboring springs discharges. Consequently, we are able to forecast, early in the season, dates of total snowmelt and springs low

  8. Development of a high-order finite volume method with multiblock partition techniques

    Directory of Open Access Journals (Sweden)

    E. M. Lemos

    2012-03-01

    Full Text Available This work deals with a new numerical methodology to solve the Navier-Stokes equations based on a finite volume method applied to structured meshes with co-located grids. High-order schemes used to approximate advective, diffusive and non-linear terms, connected with multiblock partition techniques, are the main contributions of this paper. Combination of these two techniques resulted in a computer code that involves high accuracy due the high-order schemes and great flexibility to generate locally refined meshes based on the multiblock approach. This computer code has been able to obtain results with higher or equal accuracy in comparison with results obtained using classical procedures, with considerably less computational effort.

  9. Adjustable mounting device for high-volume production of beam-shaping systems for high-power diode lasers

    Science.gov (United States)

    Haag, Sebastian; Bernhardt, Henning; Rübenach, Olaf; Haverkamp, Tobias; Müller, Tobias; Zontar, Daniel; Brecher, Christian

    2015-02-01

    In many applications for high-power diode lasers, the production of beam-shaping and homogenizing optical systems experience rising volumes and dynamical market demands. The automation of assembly processes on flexible and reconfigurable machines can contribute to a more responsive and scalable production. The paper presents a flexible mounting device designed for the challenging assembly of side-tab based optical systems. It provides design elements for precisely referencing and fixating two optical elements in a well-defined geometric relation. Side tabs are presented to the machine allowing the application of glue and a rotating mechanism allows the attachment to the optical elements. The device can be adjusted to fit different form factors and it can be used in high-volume assembly machines. The paper shows the utilization of the device for a collimation module consisting of a fast-axis and a slow-axis collimation lens. Results regarding the repeatability and process capability of bonding side tab assemblies as well as estimates from 3D simulation for overall performance indicators achieved such as cycle time and throughput will be discussed.

  10. Determination of radionuclide concentrations in ground level air using the ASS-500 high volume sampler

    International Nuclear Information System (INIS)

    Frenzel, E.; Arnold, D.; Wershofen, H.

    1996-01-01

    A method for determination of radionuclide concentrations in air aerosol samples collected by the high volume aerosol sampler ASS-500 was elaborated. The aerosol sampling station ASS-500 is a Stand alone, all-weather proofed instrument. It is designed for representative sampling of airborne radionuclides from ground level air at a height of about 1.5 m above ground level. The ASS-500 station enables continuous air monitoring both normal and emergency Situations. The collection of aerosols on the Petrianov FPP-15-1.5 type filter out of an air volume of about 100,000 m 3 (sampling period 1 wk) or of about 250,000 m 3 (sampling period 3 wk) admits accurate spectrometric low level measurements of natural and artificial radionuclides. The achieved detection limit is 0.5 μBq m -3 and 0.2 μBq m -3 for 137 Cs, respectively. A new developed air flow Meter system allows to enhance the collected air volume to about 150,000 m 3 per week and lowers the detection limit to -3 for 137 Cs for weekly collected aerosol samples. In Poland the CLOR uses 9 Stations ASS-500 at different sites as atmospheric radioactivity control system. On the basis of spectrometric measurements of natural and artificial radionuclides in the collected aerosol samples at the different sites, CLOR establishes a weekly report about the radiological situation at Poland for responsible authorities. The very low achievable detection limit of the Station ASS-500 due 10 the high air flow fate and the long possible sampling period were the key argument for other government radiation protection authorities in Europe to introduce the Station ASS-500 into their low level radionuclide atmospheric monitoring programs (Austria, Belarus, France, Germany, Iceland, Spain, Switzerland, Ukraine)

  11. Pozzolanic Activity Assessment of LUSI (LUmpur SIdoarjo) Mud in Semi High Volume Pozzolanic Mortar

    Science.gov (United States)

    Hardjito, Djwantoro; Antoni; Wibowo, Gunadi M.; Christianto, Danny

    2012-01-01

    LUSI mud obtained from the mud volcano in Sidoarjo, Indonesia, is a viable aluminosilicate material to be utilized as pozzolanic material. LUSI is an abbreviation of the local name of the mud, i.e., Lumpur Sidoarjo, meaning Sidoarjo mud. This paper reports the results of an investigation to assess the pozzolanic activity of LUSI mud, especially in semi high volume pozzolanic mortar. In this case, the amount of mud incorporated is between 30% to 40% of total cementitious material, by mass. The content of SiO2 in the mud is about 30%, whilst the total content of SiO2, Fe2O3 and Al2O3 is more than 70%. Particle size and degree of partial cement replacement by treated LUSI mud affect the compressive strength, the strength activity index (SAI), the rate of pozzolanic activity development, and the workability of mortar incorporating LUSI mud. Manufacturing semi high volume LUSI mud mortar, up to at least 40% cement replacement, is a possibility, especially with a smaller particle size of LUSI mud, less than 63 μm. The use of a larger percentage of cement replacement by LUSI mud does not show any adverse effect on the water demand, as the flow of the fresh mortar increased with the increase of percentage of LUSI mud usage.

  12. Blood Volume, Plasma Volume and Circulation Time in a High-Energy-Demand Teleost, the Yellowfin Tuna (Thunnus Albacares)

    DEFF Research Database (Denmark)

    Brill, R.W.; Cousins, K.L.; Jones, D.R.

    1998-01-01

    We measured red cell space with 51Cr-labeled red blood cells, and dextran space with 500 kDa fluorescein-isothiocyanate-labeled dextran (FITC-dextran), in two groups of yellowfin tuna (Thunnus albacares). Red cell space was 13.8+/-0.7 ml kg-1 (mean +/- s.e.m.) Assuming a whole- body hematocrit...... for albacore (Thunnus alalunga, 82-197 ml kg-1). Plasma volume within the primary circulatory system (calculated from the 51Cr-labeled red blood cell data) was 32.9+/-2.3 ml kg-1. Dextran space was 37.0+/-3.7 ml kg-1. Because 500 kDa FITC-dextran appeared to remain within the vascular space, these data imply...

  13. Development of Small-Volume, High-Precision, and Reliable Cryogenic Linear Actuators by Using Novel Intermetallic Compounds

    Data.gov (United States)

    National Aeronautics and Space Administration — Space missions often involve ultra-cold environments, and cryogenic actuators must be mechanically robust for long-term cyclic work, generate high power per volume,...

  14. Immobilization of defense high-level waste: an assessment of technological strategies and potential regulatory goals. Volume II

    International Nuclear Information System (INIS)

    1979-06-01

    This volume contains the following appendices: selected immobilization processes, directory of selected European organizations involved in HLW management, U.S. high-level waste inventories, and selected European HLW program

  15. Feasibility of disposal of high-level radioactive waste into the seabed. Volume 4: Engineering

    International Nuclear Information System (INIS)

    Hickerson, J.; Freeman, T.J.; Boisson, J.Y.; Murray, C.N.; Gera, F.; Nakamura, H.; Nieuwenhuis, J.D.; Schaller, K.H.

    1988-01-01

    One of the options suggested for disposal of high-level radioactive waste resulting from the generation of nuclear power is burial beneath the deep ocean floor in geologically stable sediment formations which have no economic value. The 8-volume series provides an assessment of the technical feasibility and radiological safety of this disposal concept based on the results obtained by ten years of co-operation and information exchange among the Member countries participating in the NEA Seabed Working Group. This report summarizes work performed to develop and evaluate engineering methods of emplacing high level radioactive waste in stable, deep ocean sediments. It includes results of desktop studies, laboratory experiments and field tests conducted in deep water

  16. Eating disorders, energy intake, training volume, and menstrual function in high-level modern rhythmic gymnasts.

    Science.gov (United States)

    Sundgot-Borgen, J

    1996-06-01

    This study examined clinical and subclinical eating disorders (EDs) in young Norwegian modern rhythmic gymnasts. Subjects were 12 members of the national team, age 13-20 years, and individually matched nonathletic controls. All subjects participated in a structured clinical interview for EDs, medical examination, and dietary analysis. Two of the gymnasts met the DSM-III-R criteria for anorexia nervosa, and 2 met the criteria for anorexia athletica (a subclinical ED). All the gymnasts were dieting in spite of the fact that they were all extremely lean. The avoidance of maturity, menstrual irregularities, energy deficit, high training volume, and high frequency of injuries were common features among the gymnasts. Ther is a need to learn more about risk factors and the etiology of EDs in different sports. Coaches, parents, and athletes need more information about principles of proper nutrition and methods to achieve ideal body composition for optional health and athletic performance.

  17. Middleware Proxy: A Request-Driven Messaging Broker For High Volume Data Distribution

    CERN Document Server

    Sliwinski, W; Dworak, A

    2014-01-01

    Nowadays, all major infrastructures and data centres (commercial and scientific) make an extensive use of the publish-subscribe messaging paradigm, which helps to decouple the message sender (publisher) from the message receiver (consumer). This paradigm is also heavily used in the CERN Accelerator Control system, in Proxy broker - critical part of the Controls Middleware (CMW) project. Proxy provides the aforementioned publish-subscribe facility and also supports execution of synchronous read and write operations. Moreover, it enables service scalability and dramatically reduces the network resources and overhead (CPU and memory) on publisher machine, required to serve all subscriptions. Proxy was developed in modern C++, using state of the art programming techniques (e.g. Boost) and following recommended software patterns for achieving low-latency and high concurrency. The outstanding performance of the Proxy infrastructure was confirmed during the last 3 years by delivering the high volume of LHC equipment...

  18. Feasibility of disposal of high-level radioactive waste into the seabed. Volume 2: Radiological assessment

    International Nuclear Information System (INIS)

    Marsily, G. de; Berhendt, V.; Ensminger, D.; Flebus, C.; Hutchinson, B.; Kane, P.; Karpf, A.; Klett, R.; Mobbs, S.; Poulin, M.; Stanner, D.

    1988-01-01

    One of the options suggested for disposal of high-level radioactive waste resulting from the generation of nuclear power is burial beneath the deep ocean floor in geologically stable sediment formations which have no economic value. The 8-volume series provides an assessment of the technical feasibility and radiological safety of this disposal concept based on the results obtained by ten years of co-operation and information exchange among the Member countries participating in the NEA Seabed Working Group. This report presents the results of the radiological assessment which consists in estimating the detriment to man and to the environment which could result from the disposal of high level nuclear waste within seabed sediments in the deep oceans

  19. Using electrochemical separation to reduce the volume of high-level nuclear waste

    International Nuclear Information System (INIS)

    Slater, S.A.; Gay, E.C.

    1998-01-01

    Argonne National Laboratory (ANL) has developed an electrochemical separation technique called electrorefining that will treat a variety of metallic spent nuclear fuel and reduce the volume of high-level nuclear waste that requires disposal. As part of that effort, ANL has developed a high throughput electrorefiner (HTER) that has a transport rate approximately three times faster than electrorefiners previously developed at ANL. This higher rate is due to the higher electrode surface area, a shorter transport path, and more efficient mixing, which leads to smaller boundary layers about the electrodes. This higher throughput makes electrorefining an attractive option in treating Department of Energy spent nuclear fuels. Experiments have been done to characterize the HTER, and a simulant metallic fuel has been successfully treated. The HTER design and experimental results is discussed

  20. Flexural Behavior of High-Volume Steel Fiber Cementitious Composite Externally Reinforced with Basalt FRP Sheet

    Directory of Open Access Journals (Sweden)

    Seungwon Kim

    2016-01-01

    Full Text Available High-performance fiber-reinforced cementitious composites (HPFRCCs are characterized by unique tensile strain hardening and multiple microcracking behaviors. The HPFRCC, which demonstrates remarkable properties such as strength, ductility, toughness, durability, stiffness, and thermal resistance, is a class of fiber cement composite with fine aggregates. It can withstand tensile stresses by forming distributed microcracks owing to the embedded fibers in the concrete, which improve the energy absorption capacity and apparent ductility. This high energy absorbing capacity can be enhanced further by an external stiff fiber-reinforced polymer (FRP. Basalt fabric is externally bonded as a sheet on concrete materials to enhance the durability and resistance to fire and other environmental attacks. This study investigates the flexural performance of an HPFRCC that is externally reinforced with multiple layers of basalt FRP. The HPFRCC considered in the study contains steel fibers at a volume fraction of 8%.

  1. High-voltage electrode optimization towards uniform surface treatment by a pulsed volume discharge

    International Nuclear Information System (INIS)

    Ponomarev, A V; Pedos, M S; Scherbinin, S V; Mamontov, Y I; Ponomarev, S V

    2015-01-01

    In this study, the shape and material of the high-voltage electrode of an atmospheric pressure plasma generation system were optimised. The research was performed with the goal of achieving maximum uniformity of plasma treatment of the surface of the low-voltage electrode with a diameter of 100 mm. In order to generate low-temperature plasma with the volume of roughly 1 cubic decimetre, a pulsed volume discharge was used initiated with a corona discharge. The uniformity of the plasma in the region of the low-voltage electrode was assessed using a system for measuring the distribution of discharge current density. The system's low-voltage electrode - collector - was a disc of 100 mm in diameter, the conducting surface of which was divided into 64 radially located segments of equal surface area. The current at each segment was registered by a high-speed measuring system controlled by an ARM™-based 32-bit microcontroller. To facilitate the interpretation of results obtained, a computer program was developed to visualise the results. The program provides a 3D image of the current density distribution on the surface of the low-voltage electrode. Based on the results obtained an optimum shape for a high-voltage electrode was determined. Uniformity of the distribution of discharge current density in relation to distance between electrodes was studied. It was proven that the level of non-uniformity of current density distribution depends on the size of the gap between electrodes. Experiments indicated that it is advantageous to use graphite felt VGN-6 (Russian abbreviation) as the material of the high-voltage electrode's emitting surface. (paper)

  2. Investigation of tDCS volume conduction effects in a highly realistic head model

    Science.gov (United States)

    Wagner, S.; Rampersad, S. M.; Aydin, Ü.; Vorwerk, J.; Oostendorp, T. F.; Neuling, T.; Herrmann, C. S.; Stegeman, D. F.; Wolters, C. H.

    2014-02-01

    Objective. We investigate volume conduction effects in transcranial direct current stimulation (tDCS) and present a guideline for efficient and yet accurate volume conductor modeling in tDCS using our newly-developed finite element (FE) approach. Approach. We developed a new, accurate and fast isoparametric FE approach for high-resolution geometry-adapted hexahedral meshes and tissue anisotropy. To attain a deeper insight into tDCS, we performed computer simulations, starting with a homogenized three-compartment head model and extending this step by step to a six-compartment anisotropic model. Main results. We are able to demonstrate important tDCS effects. First, we find channeling effects of the skin, the skull spongiosa and the cerebrospinal fluid compartments. Second, current vectors tend to be oriented towards the closest higher conducting region. Third, anisotropic WM conductivity causes current flow in directions more parallel to the WM fiber tracts. Fourth, the highest cortical current magnitudes are not only found close to the stimulation sites. Fifth, the median brain current density decreases with increasing distance from the electrodes. Significance. Our results allow us to formulate a guideline for volume conductor modeling in tDCS. We recommend to accurately model the major tissues between the stimulating electrodes and the target areas, while for efficient yet accurate modeling, an exact representation of other tissues is less important. Because for the low-frequency regime in electrophysiology the quasi-static approach is justified, our results should also be valid for at least low-frequency (e.g., below 100 Hz) transcranial alternating current stimulation.

  3. High-Performance Home Technologies: Solar Thermal & Photovoltaic Systems; Volume 6 Building America Best Practices Series

    Energy Technology Data Exchange (ETDEWEB)

    None

    2007-06-01

    The sixth volume of the Building America Best Practices Series presents information that is useful throughout the U.S. for enhancing the energy efficiency practices in the specific climate zones that are presented in each of the volumes.

  4. Mixing subattolitre volumes in a quantitative and highly parallel manner with soft matter nanofluidics

    DEFF Research Database (Denmark)

    Christensen, Sune M.; Bolinger, Pierre-Yves; Hatzakis, Nikos

    2012-01-01

    Handling and mixing ultrasmall volumes of reactants in parallel can increase the throughput and complexity of screening assays while simultaneously reducing reagent consumption. Microfabricated silicon and plastic can provide reliable fluidic devices, but cannot typically handle total volumes sma...

  5. High concentration tritium gas measurement with small volume ionization chambers for fusion fuel gas monitors

    International Nuclear Information System (INIS)

    Uda, Tatsuhiko; Okuno, Kenji; Matsuda, Yuji; Naruse, Yuji

    1991-01-01

    To apply ionization chambers to fusion fuel gas processing systems, high concentration tritium gas was experimentally measured with small volume 0.16 and 21.6 cm 3 ionization chambers. From plateau curves, the optimum electric field strength was obtained as 100∼200 V/cm. Detection efficiency was confirmed as dependent on the ionization ability of the filled gas, and moreover on its stopping power, because when the range of the β-rays was shortened, the probability of energy loss by collisions with the electrode and chamber wall increased. Loss of ions by recombination was prevented by using a small volume ionization chamber. For example the 0.16 cm 3 ionization chamber gave measurement with linearity to above 40% tritium gas. After the tritium gas measurements, the concentration levels inside the chamber were estimated from their memory currents. Although more than 1/4,000 of the maximum, current was observed as a memory effect, the smaller ionization chamber gave a smaller memory effect. (author)

  6. Cranial Tumor Surgical Outcomes at a High-Volume Academic Referral Center.

    Science.gov (United States)

    Brown, Desmond A; Himes, Benjamin T; Major, Brittny T; Mundell, Benjamin F; Kumar, Ravi; Kall, Bruce; Meyer, Fredric B; Link, Michael J; Pollock, Bruce E; Atkinson, John D; Van Gompel, Jamie J; Marsh, W Richard; Lanzino, Giuseppe; Bydon, Mohamad; Parney, Ian F

    2018-01-01

    To determine adverse event rates for adult cranial neuro-oncologic surgeries performed at a high-volume quaternary academic center and assess the impact of resident participation on perioperative complication rates. All adult patients undergoing neurosurgical intervention for an intracranial neoplastic lesion between January 1, 2009, and December 31, 2013, were included. Cases were categorized as biopsy, extra-axial/skull base, intra-axial, or transsphenoidal. Complications were categorized as neurologic, medical, wound, mortality, or none and compared for patients managed by a chief resident vs a consultant neurosurgeon. A total of 6277 neurosurgical procedures for intracranial neoplasms were performed. After excluding radiosurgical procedures and pediatric patients, 4151 adult patients who underwent 4423 procedures were available for analysis. Complications were infrequent, with overall rates of 9.8% (435 of 4423 procedures), 1.7% (73 of 4423), and 1.4% (63 of 4423) for neurologic, medical, and wound complications, respectively. The rate of perioperative mortality was 0.3% (14 of 4423 procedures). Case performance and management by a chief resident did not negatively impact outcome. In our large-volume brain tumor practice, rates of complications were low, and management of cases by chief residents in a semiautonomous manner did not negatively impact surgical outcomes. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  7. Non-equilibrium Inertial Separation Array for High-throughput, Large-volume Blood Fractionation.

    Science.gov (United States)

    Mutlu, Baris R; Smith, Kyle C; Edd, Jon F; Nadar, Priyanka; Dlamini, Mcolisi; Kapur, Ravi; Toner, Mehmet

    2017-08-30

    Microfluidic blood processing is used in a range of applications from cancer therapeutics to infectious disease diagnostics. As these applications are being translated to clinical use, processing larger volumes of blood in shorter timescales with high-reliability and robustness is becoming a pressing need. In this work, we report a scaled, label-free cell separation mechanism called non-equilibrium inertial separation array (NISA). The NISA mechanism consists of an array of islands that exert a passive inertial lift force on proximate cells, thus enabling gentler manipulation of the cells without the need of physical contact. As the cells follow their size-based, deterministic path to their equilibrium positions, a preset fraction of the flow is siphoned to separate the smaller cells from the main flow. The NISA device was used to fractionate 400 mL of whole blood in less than 3 hours, and produce an ultrapure buffy coat (96.6% white blood cell yield, 0.0059% red blood cell carryover) by processing whole blood at 3 mL/min, or ∼300 million cells/second. This device presents a feasible alternative for fractionating blood for transfusion, cellular therapy and blood-based diagnostics, and could significantly improve the sensitivity of rare cell isolation devices by increasing the processed whole blood volume.

  8. Synthesis and characterization of high volume fraction Al-Al2O3 nanocomposite powders by high-energy milling

    International Nuclear Information System (INIS)

    Prabhu, B.; Suryanarayana, C.; An, L.; Vaidyanathan, R.

    2006-01-01

    Al-Al 2 O 3 metal matrix composite (MMC) powders with volume fractions of 20, 30, and 50% Al 2 O 3 were synthesized by high-energy milling of the blended component powders. The particle sizes of Al 2 O 3 studied were 50 nm, 150 nm, and 5 μm. A uniform distribution of the Al 2 O 3 reinforcement in the Al matrix was successfully obtained after milling the powders for a period of 20 h at a ball-to-powder ratio of 10:1 in a SPEX mill. The uniform distribution of Al 2 O 3 in the Al matrix was confirmed by characterizing these nanocomposite powders by scanning electron microscopy (SEM), energy dispersive spectrometry (EDS), X-ray mapping, and X-ray diffraction (XRD) techniques

  9. High production volume chemical Amine Oxide [C8-C20] category environmental risk assessment

    DEFF Research Database (Denmark)

    Sanderson, Hans; Tibazarwa, Caritas; Greggs, William

    2009-01-01

    and personal care products. Given the lack of persistence or bioaccumulation, and the low likelihood of these chemicals partitioning to soil, the focus of the environmental assessment is on the aquatic environment. In the United States, the E-FAST model is used to estimate effluent concentrations in the United......An environmental assessment of amine oxides has been conducted under the OECD SIDS High Production Volume (HPV) Program via the Global International Council of Chemical Associations (ICCA) Amine Oxides Consortium. Amine oxides are primarily used in conjunction with surfactants in cleaning...... States from manufacturing facilities and from municipal facilities resulting from consumer product uses. Reasonable worst-case ratios of predicted environmental concentration (PEC) to predicted no effect concentration (PNEC) range from 0.04 to 0.003, demonstrating that these chemicals are a low risk...

  10. [Efficiency of high-volume hemofiltration in patients with severe sepsis and intracranial hypertension].

    Science.gov (United States)

    Musaeva, T S; Berdnikov, A P; Goncharenko, S I; Denisova, E A

    2014-01-01

    We performed a retrospective study in 68 patients (144 procedures) with severe sepsis and intracranial hypertension measured by the pressure in the central retinal vein. The patients underwent high-volume hemofiltration (HV-HF) for extrarenal indications. Increased pressure in the central retinal vein was accompanied by critical points of cerebral perfusion pressure and the growth of neurological deficit with inhibition level of consciousness to coma 1. In this case, IHV-HF may be associated with the formation of the critical points of cerebral perfihsion and severe disorders of microcirculation and the lack of resolution of tissue hypoperfusion. In case of intracranial hypertension IHV-HF is not effective in the category of patients where there is a combination ΔpCO2 > 5.9 mm Hg level and GCS <10 points.

  11. Challenges and solutions for high-volume testing of silicon photonics

    Science.gov (United States)

    Polster, Robert; Dai, Liang Yuan; Oikonomou, Michail; Cheng, Qixiang; Rumley, Sebastien; Bergman, Keren

    2018-02-01

    The first generation of silicon photonic products is now commercially available. While silicon photonics possesses key economic advantages over classical photonic platforms, it has yet to become a commercial success because these advantages can be fully realized only when high-volume testing of silicon photonic devices is made possible. We discuss the costs, challenges, and solutions of photonic chip testing as reported in the recent research literature. We define and propose three underlying paradigms that should be considered when creating photonic test structures: Design for Fast Coupling, Design for Minimal Taps, and Design for Parallel Testing. We underline that a coherent test methodology must be established prior to the design of test structures, and demonstrate how an optimized methodology dramatically reduces the burden when designing for test, by reducing the needed complexity of test structures.

  12. High volume hydraulic fracturing operations: potential impacts on surface water and human health.

    Science.gov (United States)

    Mrdjen, Igor; Lee, Jiyoung

    2016-08-01

    High volume, hydraulic fracturing (HVHF) processes, used to extract natural gas and oil from underground shale deposits, pose many potential hazards to the environment and human health. HVHF can negatively affect the environment by contaminating soil, water, and air matrices with potential pollutants. Due to the relatively novel nature of the process, hazards to surface waters and human health are not well known. The purpose of this article is to link the impacts of HVHF operations on surface water integrity, with human health consequences. Surface water contamination risks include: increased structural failure rates of unconventional wells, issues with wastewater treatment, and accidental discharge of contaminated fluids. Human health risks associated with exposure to surface water contaminated with HVHF chemicals include increased cancer risk and turbidity of water, leading to increased pathogen survival time. Future research should focus on modeling contamination spread throughout the environment, and minimizing occupational exposure to harmful chemicals.

  13. Effects of 12 weeks high-intensity & reduced-volume training in elite athletes

    DEFF Research Database (Denmark)

    Kilen, Anders; Larsson, Tanja Hultengren; Jørgensen, Majke

    2014-01-01

    It was investigated if high-intensity interval training (HIT) at the expense of total training volume improves performance, maximal oxygen uptake and swimming economy. 41 elite swimmers were randomly allocated to a control (CON) or HIT group. For 12 weeks both groups trained ∼12 h per week. HIT c...... (3.8±0.7 vs. 3.8±0.7 l O2×min-1; n = 11) group. Oxygen uptake determined at fixed submaximal speed was not significantly affected in either group by the intervention. Body fat % tended to increase (P = 0.09) in the HIT group (15.4±1.6% vs. 16.3±1.6%; P = 0.09; n = 16) and increased (P...

  14. Reduction on high level radioactive waste volume and geological repository footprint with high burn-up and high thermal efficiency of HTGR

    Energy Technology Data Exchange (ETDEWEB)

    Fukaya, Yuji, E-mail: fukaya.yuji@jaea.go.jp; Nishihara, Tetsuo

    2016-10-15

    Highlights: • We evaluate the number of canisters and its footprint for HTGR. • We proposed new waste loading method for direct disposal of HTGR. • HTGR can significantly reduce HLW volume compared with LWR. - Abstract: Reduction on volume of High Level radioactive Waste (HLW) and footprint in a geological repository due to high burn-up and high thermal efficiency of High Temperature Gas-cooled Reactor (HTGR) has been investigated. A helium-cooled and graphite-moderated commercial HTGR was designed as a Gas Turbine High Temperature Reactor (GTHTR300), and that has particular features such as significantly high burn-up of approximately 120 GWd/t, high thermal efficiency around 50%, and pin-in-block type fuel. The pin-in-block type fuel was employed to reduce processed graphite volume in reprocessing. By applying the feature, effective waste loading method for direct disposal is proposed in this study. By taking into account these feature, the number of HLW canister generations and its repository footprint are evaluated by burn-up fuel composition, thermal calculation and criticality calculation in repository. As a result, it is found that the number of canisters and its repository footprint per electricity generation can be reduced by 60% compared with Light Water Reactor (LWR) representative case for direct disposal because of the higher burn-up, higher thermal efficiency, less TRU generation, and effective waste loading proposed in this study for HTGR. But, the reduced ratios change to 20% and 50% if the long term durability of LWR canister is guaranteed. For disposal with reprocessing, the number of canisters and its repository footprint per electricity generation can be reduced by 30% compared with LWR because of the 30% higher thermal efficiency of HTGR.

  15. Fast and effective determination of strontium-90 in high volumes water samples

    International Nuclear Information System (INIS)

    Basarabova, B.; Dulanska, S.

    2014-01-01

    A simple and fast method was developed for determination of 90 Sr in high volumes of water samples from vicinity of nuclear power facilities. Samples were taken from the environment near Nuclear Power Plants in Jaslovske Bohunice and Mochovce in Slovakia. For determination of 90 Sr was used solid phase extraction using commercial sorbent Analig R Sr-01 from company IBC Advanced Technologies, Inc.. Determination of 90 Sr was performed with dilute solution of HNO 3 (1.5-2 M) and also tested in base medium with NaOH. For elution of 90 Sr was used eluent EDTA with pH in range 8-9. To achieve fast determination, automation was applied, which brings significant reduction of separation time. Concentration of water samples with evaporation was not necessary. Separation was performed immediately after filtration of analyzed samples. The aim of this study was development of less expensive, time unlimited and energy saving method for determination of 90 Sr in comparison with conventional methods. Separation time for fast-flow with volume of 10 dm 3 of water samples was 3.5 hours (flow-rate approximately 3.2 dm 3 / 1 hour). Radiochemical strontium yield was traced by using radionuclide 85 Sr. Samples were measured with HPGe detector (High-purity Germanium detector) at energy E φ = 514 keV. By using Analig R Sr-01 yields in range 72 - 96 % were achieved. Separation based on solid phase extraction using Analig R Sr-01 employing utilization of automation offers new, fast and effective method for determination of 90 Sr in water matrix. After ingrowth of yttrium samples were measured by Liquid Scintillation Spectrometer Packard Tricarb 2900 TR with software Quanta Smart. (authors)

  16. High volume fly ash RCC for dams - I : mixture optimization and mechanical properties

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, S. [PEAB Construction Co., Oslo (Norway); Lahus, O. [Norwegian Building Research Inst., Oslo (Norway)

    2001-07-01

    Roller compacted concretes (RCC) were developed for the Norwegian Skjerka hydropower project. RCCs were developed to have a high-volume fly ash content to address environmental issues, including the reduction of carbon dioxide emissions associated with dam construction. They also makes good use of waste product and conserve natural resources. This study examined a series of mixtures to determine the appropriateness of using RCC as a competing alternative to the traditional rock fill dam proposed for the Skjerka hydropower project. The main advantage of RCC is speed, allowing a relatively large dam to be constructed in just one summer season, saving financial costs and providing early return on the investment. In addition, fly ash can be used in the structure, using clean and renewable energy. Several procedures to proportion RCC mixtures were proposed, including the optimal paste volume method which is based on the assumption that an optimal RCC should have just enough paste to fill the space between particles when the granular skeleton has reached its maximum density under compaction. With this assumption, RCC tests began in 1998 in the laboratories of the Norwegian Building Research Institute. An ordinary portland cement was used and combined with ordinary low lime fly ash. Both coarse and fine aggregate were used. The tests determined the optimum paste-mortar ratio, the content of coarse aggregates and the production of specimens for test on hardened and fresh concrete. The study showed that the compressive strength of RCC increased with increasing cement/(cement + fly ash) ratio. The permeability coefficient decreased with increasing cement-content and increasing cement/(cement + fly ash) ratio due to the slow pozzolanic reaction of fly ash making a more open pore structure. It was concluded that an optimized mixture can result in a high performance RCC in terms of fresh and hardened concrete properties. 15 refs., 5 tabs., 11 figs.

  17. Measuring the volume of cingulate cortex in Chinese normal adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Zhang Chao; Chen Nan; Wang Xing; Li Kuncheng; Zhou Xin; Zhuo Yan; Chen Lin

    2010-01-01

    correlated with age (r=-0.330, -0.324, -0.169, -0.243, P<0.05), though the correlation coefficient is not high. Conclusions: Cingulate cortex volume could be accurately measured on the high-resolution MRI with 3D volume analysis software, which can provide morphological data for the construction of database for Chinese Standard Brain. The results may provide normal range for the diagnosis of the volumetric deficits of cingulate cortex. (authors)

  18. Application of advanced diffraction based optical metrology overlay capabilities for high-volume manufacturing

    Science.gov (United States)

    Chen, Kai-Hsiung; Huang, Guo-Tsai; Hsieh, Hung-Chih; Ni, Wei-Feng; Chuang, S. M.; Chuang, T. K.; Ke, Chih-Ming; Huang, Jacky; Rao, Shiuan-An; Cumurcu Gysen, Aysegul; d'Alfonso, Maxime; Yueh, Jenny; Izikson, Pavel; Soco, Aileen; Wu, Jon; Nooitgedagt, Tjitte; Ottens, Jeroen; Kim, Yong Ho; Ebert, Martin

    2017-03-01

    On-product overlay requirements are becoming more challenging with every next technology node due to the continued decrease of the device dimensions and process tolerances. Therefore, current and future technology nodes require demanding metrology capabilities such as target designs that are robust towards process variations and high overlay measurement density (e.g. for higher order process corrections) to enable advanced process control solutions. The impact of advanced control solutions based on YieldStar overlay data is being presented in this paper. Multi patterning techniques are applied for critical layers and leading to additional overlay measurement demands. The use of 1D process steps results in the need of overlay measurements relative to more than one layer. Dealing with the increased number of overlay measurements while keeping the high measurement density and metrology accuracy at the same time presents a challenge for high volume manufacturing (HVM). These challenges are addressed by the capability to measure multi-layer targets with the recently introduced YieldStar metrology tool, YS350. On-product overlay results of such multi-layers and standard targets are presented including measurement stability performance.

  19. Moderate Recovery Unnecessary to Sustain High Stroke Volume during Interval Training. A Brief Report

    Directory of Open Access Journals (Sweden)

    Jamie Stanley

    2014-06-01

    Full Text Available It has been suggested that the time spent at a high stroke volume (SV is important for improving maximal cardiac function. The aim of this study was to examine the effect of recovery intensity on cardiovascular parameters during a typical high-intensity interval training (HIIT session in fourteen well-trained cyclists. Oxygen consumption (VO2, heart rate (HR, SV, cardiac output (Qc, and oxygenation of vastus lateralis (TSI were measured during a HIIT (3×3-min work period, 2 min of recovery session on two occasions. VO2, HR and Qc were largely higher during moderate-intensity (60% compared with low-intensity (30% (VO2, effect size; ES = +2.6; HR, ES = +2.8; Qc, ES = +2.2 and passive (HR, ES = +2.2; Qc, ES = +1.7 recovery. By contrast, there was no clear difference in SV between the three recovery conditions, with the SV during the two active recovery periods not being substantially different than during exercise (60%, ES = −0.1; 30%, ES = −0.2. To conclude, moderate-intensity recovery may not be required to maintain a high SV during HIIT.

  20. High-Dimensional Function Approximation With Neural Networks for Large Volumes of Data.

    Science.gov (United States)

    Andras, Peter

    2018-02-01

    Approximation of high-dimensional functions is a challenge for neural networks due to the curse of dimensionality. Often the data for which the approximated function is defined resides on a low-dimensional manifold and in principle the approximation of the function over this manifold should improve the approximation performance. It has been show that projecting the data manifold into a lower dimensional space, followed by the neural network approximation of the function over this space, provides a more precise approximation of the function than the approximation of the function with neural networks in the original data space. However, if the data volume is very large, the projection into the low-dimensional space has to be based on a limited sample of the data. Here, we investigate the nature of the approximation error of neural networks trained over the projection space. We show that such neural networks should have better approximation performance than neural networks trained on high-dimensional data even if the projection is based on a relatively sparse sample of the data manifold. We also find that it is preferable to use a uniformly distributed sparse sample of the data for the purpose of the generation of the low-dimensional projection. We illustrate these results considering the practical neural network approximation of a set of functions defined on high-dimensional data including real world data as well.

  1. Survival rate in nasopharyngeal carcinoma improved by high caseload volume: a nationwide population-based study in Taiwan

    International Nuclear Information System (INIS)

    Lee, Ching-Chih; Hung, Shih-Kai; Huang, Tze-Ta; Lee, Moon-Sing; Su, Yu-Chieh; Chou, Pesus; Hsiao, Shih-Hsuan; Chiou, Wen-Yen; Lin, Hon-Yi; Chien, Sou-Hsin

    2011-01-01

    Positive correlation between caseload and outcome has previously been validated for several procedures and cancer treatments. However, there is no information linking caseload and outcome of nasopharyngeal carcinoma (NPC) treatment. We used nationwide population-based data to examine the association between physician case volume and survival rates of patients with NPC. Between 1998 and 2000, a total of 1225 patients were identified from the Taiwan National Health Insurance Research Database. Survival analysis, the Cox proportional hazards model, and propensity score were used to assess the relationship between 10-year survival rates and physician caseloads. As the caseload of individual physicians increased, unadjusted 10-year survival rates increased (p < 0.001). Using a Cox proportional hazard model, patients with NPC treated by high-volume physicians (caseload ≥ 35) had better survival rates (p = 0.001) after adjusting for comorbidities, hospital, and treatment modality. When analyzed by propensity score, the adjusted 10-year survival rate differed significantly between patients treated by high-volume physicians and patients treated by low/medium-volume physicians (75% vs. 61%; p < 0.001). Our data confirm a positive volume-outcome relationship for NPC. After adjusting for differences in the case mix, our analysis found treatment of NPC by high-volume physicians improved 10-year survival rate

  2. A high-throughput platform for low-volume high-temperature/pressure sealed vessel solvent extractions

    International Nuclear Information System (INIS)

    Damm, Markus; Kappe, C. Oliver

    2011-01-01

    Highlights: ► Parallel low-volume coffee extractions in sealed-vessel HPLC/GC vials. ► Extractions are performed at high temperatures and pressures (200 °C/20 bar). ► Rapid caffeine determination from the liquid phase. ► Headspace analysis of volatiles using solid-phase microextraction (SPME). - Abstract: A high-throughput platform for performing parallel solvent extractions in sealed HPLC/GC vials inside a microwave reactor is described. The system consist of a strongly microwave-absorbing silicon carbide plate with 20 cylindrical wells of appropriate dimensions to be fitted with standard HPLC/GC autosampler vials serving as extraction vessels. Due to the possibility of heating up to four heating platforms simultaneously (80 vials), efficient parallel analytical-scale solvent extractions can be performed using volumes of 0.5–1.5 mL at a maximum temperature/pressure limit of 200 °C/20 bar. Since the extraction and subsequent analysis by either gas chromatography or liquid chromatography coupled with mass detection (GC–MS or LC–MS) is performed directly from the autosampler vial, errors caused by sample transfer can be minimized. The platform was evaluated for the extraction and quantification of caffeine from commercial coffee powders assessing different solvent types, extraction temperatures and times. For example, 141 ± 11 μg caffeine (5 mg coffee powder) were extracted during a single extraction cycle using methanol as extraction solvent, whereas only 90 ± 11 were obtained performing the extraction in methylene chloride, applying the same reaction conditions (90 °C, 10 min). In multiple extraction experiments a total of ∼150 μg caffeine was extracted from 5 mg commercial coffee powder. In addition to the quantitative caffeine determination, a comparative qualitative analysis of the liquid phase coffee extracts and the headspace volatiles was performed, placing special emphasis on headspace analysis using solid-phase microextraction (SPME

  3. A high-throughput platform for low-volume high-temperature/pressure sealed vessel solvent extractions

    Energy Technology Data Exchange (ETDEWEB)

    Damm, Markus [Christian Doppler Laboratory for Microwave Chemistry (CDLMC) and Institute of Chemistry, Karl-Franzens-University Graz, Heinrichstrasse 28, A-8010 Graz (Austria); Kappe, C. Oliver, E-mail: oliver.kappe@uni-graz.at [Christian Doppler Laboratory for Microwave Chemistry (CDLMC) and Institute of Chemistry, Karl-Franzens-University Graz, Heinrichstrasse 28, A-8010 Graz (Austria)

    2011-11-30

    Highlights: Black-Right-Pointing-Pointer Parallel low-volume coffee extractions in sealed-vessel HPLC/GC vials. Black-Right-Pointing-Pointer Extractions are performed at high temperatures and pressures (200 Degree-Sign C/20 bar). Black-Right-Pointing-Pointer Rapid caffeine determination from the liquid phase. Black-Right-Pointing-Pointer Headspace analysis of volatiles using solid-phase microextraction (SPME). - Abstract: A high-throughput platform for performing parallel solvent extractions in sealed HPLC/GC vials inside a microwave reactor is described. The system consist of a strongly microwave-absorbing silicon carbide plate with 20 cylindrical wells of appropriate dimensions to be fitted with standard HPLC/GC autosampler vials serving as extraction vessels. Due to the possibility of heating up to four heating platforms simultaneously (80 vials), efficient parallel analytical-scale solvent extractions can be performed using volumes of 0.5-1.5 mL at a maximum temperature/pressure limit of 200 Degree-Sign C/20 bar. Since the extraction and subsequent analysis by either gas chromatography or liquid chromatography coupled with mass detection (GC-MS or LC-MS) is performed directly from the autosampler vial, errors caused by sample transfer can be minimized. The platform was evaluated for the extraction and quantification of caffeine from commercial coffee powders assessing different solvent types, extraction temperatures and times. For example, 141 {+-} 11 {mu}g caffeine (5 mg coffee powder) were extracted during a single extraction cycle using methanol as extraction solvent, whereas only 90 {+-} 11 were obtained performing the extraction in methylene chloride, applying the same reaction conditions (90 Degree-Sign C, 10 min). In multiple extraction experiments a total of {approx}150 {mu}g caffeine was extracted from 5 mg commercial coffee powder. In addition to the quantitative caffeine determination, a comparative qualitative analysis of the liquid phase coffee

  4. High- versus low-volume polyethylene glycol plus laxative versus sennosides for colonoscopy preparation in children.

    Science.gov (United States)

    Kierkus, Jaroslaw; Horvath, Andrea; Szychta, Monika; Woynarowski, Marek; Wegner, Agnieszka; Wiernicka, Anna; Dadalski, Maciej; Teisseyre, Mikolaj; Dziechciarz, Piotr

    2013-08-01

    Many protocols of bowel preparation are available for use in children; however, none of them is commonly accepted. The aim of the study was to evaluate the efficacy and acceptability of high-volume polyethylene glycol (PEG) versus low-volume PEG combined with bisacodyl (BPEG) versus sennosides for colonoscopy preparation in children. Participants ages 10 to 18 years were randomly assigned to receive either PEG 60 or PEG 30 mL kg⁻¹ day⁻¹ plus oral bisacodyl 10 to 15 mg/day or sennosides 2 mg kg⁻¹ day⁻¹ for 2 days. A blinded assessment of bowel cleansing was made by the endoscopist according to the Aronchick and Ottawa scales. Patient acceptability was evaluated with the visual-analog scale. Analysis was done on an available case analysis basis. Of 240 patients enrolled in the study 234 patients were available for analysis of the efficacy of colon cleansing. There were no significant differences found among the 3 groups for the proportions of participants with excellent/good (PEG: 35/79, BPEG: 26/79, sennosides 25/76) and poor/inadequate (PEG: 20/79, BPEG: 28/79, sennosides 28/76) bowel preparation evaluated with the Aronchick scale and for the mean Ottawa total score (PEG: 5.47 ± 3.63, BPEG: 6.22 ± 3.3, sennosides: 6.18 ± 3.53). Acceptability of bowel cleansing protocol was similar in all of the groups (P = 0.8). All 3 cleansing methods showed similar efficacy and tolerability; however, none of them was satisfactory.

  5. Polarized training has greater impact on key endurance variables than threshold, high intensity or high volume training

    Directory of Open Access Journals (Sweden)

    Thomas eStöggl

    2014-02-01

    Full Text Available Endurance athletes integrate four conditioning concepts in their training programs: high-volume training (HVT, ‘threshold-training’ (THR, high-intensity interval training (HIIT and a combination of these aforementioned concepts known as polarized training (POL. The purpose of this study was to explore which of these four training concepts provides the greatest response on key components of endurance performance in well-trained endurance athletes. Methods: Forty eight runners, cyclists, triathletes and cross-country skiers (peak oxygen uptake: (VO2peak: 62.6±7.1 mL∙min-1∙kg-1 were randomly assigned to one of four groups performing over nine weeks. An incremental test, work economy and a VO2peak tests were performed. Training intensity was heart rate controlled. Results: POL demonstrated the greatest increase in VO2peak (+6.8 ml∙min∙kg-1 or 11.7%, P0.05. Conclusion: POL resulted in the greatest improvements in most key variables of endurance performance in well-trained endurance athletes. THR or HVT did not lead to further improvements in performance related variables.

  6. Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization

    International Nuclear Information System (INIS)

    Gupta, Rajiv; Brady, Tom; Grasruck, Michael; Suess, Christoph; Schmidt, Bernhard; Stierstorfer, Karl; Popescu, Stefan; Flohr, Thomas; Bartling, Soenke H.

    2006-01-01

    Digital flat-panel-based volume CT (VCT) represents a unique design capable of ultra-high spatial resolution, direct volumetric imaging, and dynamic CT scanning. This innovation, when fully developed, has the promise of opening a unique window on human anatomy and physiology. For example, the volumetric coverage offered by this technology enables us to observe the perfusion of an entire organ, such as the brain, liver, or kidney, tomographically (e.g., after a transplant or ischemic event). By virtue of its higher resolution, one can directly visualize the trabecular structure of bone. This paper describes the basic design architecture of VCT. Three key technical challenges, viz., scatter correction, dynamic range extension, and temporal resolution improvement, must be addressed for successful implementation of a VCT scanner. How these issues are solved in a VCT prototype and the modifications necessary to enable ultra-high resolution volumetric scanning are described. The fundamental principles of scatter correction and dose reduction are illustrated with the help of an actual prototype. The image quality metrics of this prototype are characterized and compared with a multi-detector CT (MDCT). (orig.)

  7. Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Rajiv; Brady, Tom [Massachusetts General Hospital, Department of Radiology, Founders House, FND-2-216, Boston, MA (United States); Grasruck, Michael; Suess, Christoph; Schmidt, Bernhard; Stierstorfer, Karl; Popescu, Stefan; Flohr, Thomas [Siemens Medical Solutions, Forchheim (Germany); Bartling, Soenke H. [Hannover Medical School, Department of Neuroradiology, Hannover (Germany)

    2006-06-15

    Digital flat-panel-based volume CT (VCT) represents a unique design capable of ultra-high spatial resolution, direct volumetric imaging, and dynamic CT scanning. This innovation, when fully developed, has the promise of opening a unique window on human anatomy and physiology. For example, the volumetric coverage offered by this technology enables us to observe the perfusion of an entire organ, such as the brain, liver, or kidney, tomographically (e.g., after a transplant or ischemic event). By virtue of its higher resolution, one can directly visualize the trabecular structure of bone. This paper describes the basic design architecture of VCT. Three key technical challenges, viz., scatter correction, dynamic range extension, and temporal resolution improvement, must be addressed for successful implementation of a VCT scanner. How these issues are solved in a VCT prototype and the modifications necessary to enable ultra-high resolution volumetric scanning are described. The fundamental principles of scatter correction and dose reduction are illustrated with the help of an actual prototype. The image quality metrics of this prototype are characterized and compared with a multi-detector CT (MDCT). (orig.)

  8. Image guided, adaptive, accelerated, high dose brachytherapy as model for advanced small volume radiotherapy

    International Nuclear Information System (INIS)

    Haie-Meder, Christine; Siebert, Frank-Andre; Poetter, Richard

    2011-01-01

    Brachytherapy has consistently provided a very conformal radiation therapy modality. Over the last two decades this has been associated with significant improvements in imaging for brachytherapy applications (prostate, gynecology), resulting in many positive advances in treatment planning, application techniques and clinical outcome. This is emphasized by the increased use of brachytherapy in Europe with gynecology as continuous basis and prostate and breast as more recently growing fields. Image guidance enables exact knowledge of the applicator together with improved visualization of tumor and target volumes as well as of organs at risk providing the basis for very individualized 3D and 4D treatment planning. In this commentary the most important recent developments in prostate, gynecological and breast brachytherapy are reviewed, with a focus on European recent and current research aiming at the definition of areas for important future research. Moreover the positive impact of GEC-ESTRO recommendations and the highlights of brachytherapy physics are discussed what altogether presents a full overview of modern image guided brachytherapy. An overview is finally provided on past and current international brachytherapy publications focusing on 'Radiotherapy and Oncology'. These data show tremendous increase in almost all research areas over the last three decades strongly influenced recently by translational research in regard to imaging and technology. In order to provide high level clinical evidence for future brachytherapy practice the strong need for comprehensive prospective clinical research addressing brachytherapy issues is high-lighted.

  9. [Effect of different volumes of fluid resuscitation on hemorrhagic shock with pulmonary edema at high altitude in the unacclimated rat].

    Science.gov (United States)

    Liu, Liang-ming; Hu, De-yao; Liu, Jian-cang; Li, Ping; Liu, Hou-dong; Xiao, Nan; Zhou, Xue-wu; Tian, Kun-lun; Huo, Xiao-ping; Shi, Quan-gui; He, Yan-mei; Yin, Zuo-ming

    2003-05-01

    To study the effects of different volumes of fluid resuscitation on hemorrhagic shock with pulmonary edema at high altitude in the unacclimated rat. One hundred and twenty-six SD rats transported to Lasa, Tibet, 3 760 meters above the sea level, were anesthetized one week later with sodium pentobarbital (30 mg/kg, intraperitoneal). Hemorrhagic shock with pulmonary edema model was induced by hemorrhage (50 mm Hg for 1 hour, 1 mmHg=0.133 kPa) plus intravenous injection of oleic acid (50 microl/kg). Experiments were then conducted in two parts. Sixty-three rats in part I were equally divided into nine groups (n=7): normal control, hemorrhagic shock control, hemorrhagic shock with pulmonary edema (HSPE) without fluid infusion, HSPE plus infusing lactated Ringer's solution (LR) with 0.5-, 1-, 1.5-, 2- or 3- fold volume shed blood, and 1 volume of LR plus mannitol (10 ml/kg). Hemodynamic parameters including mean arterial blood pressure (MAP), left intraventricular systolic pressure (LVSP) and the maximal change rate of intraventricular pressure rise or decline (+/- dp/dt max) were observed at 15, 30, 60 and 120 minutes after infusion, blood gases were measured at 30 and 120 minutes after infusion and the water content of lung and brain was determined at 120 minutes after infusion. In part II, additional 63 rats were used to observe the effect of different volumes of fluid resuscitation on survival time of HSPE rats. 0.5 volume of LR infusion significantly improved MAP, LVSP and +/- dp/dt max, prolonged the survival time of HSPE animals (all P<0.01), while it did not increase the water content of lung and brain and had no marked influence on blood gases. One volume of LR infusion slightly improved hemodynamic parameters, prolonged the survival time and increased the water content of lung. More than 1 volume of LR infusion including 1.5-, 2- and 3- fold volume LR deteriorated the hemodynamic parameters and decreased the survival time of shocked animal, meanwhile they

  10. High failure rates after (131)I therapy in Graves hyperthyroidism patients with large thyroid volumes, high iodine uptake, and high iodine turnover.

    Science.gov (United States)

    de Jong, Jeroen A F; Verkooijen, Helena M; Valk, Gerlof D; Zelissen, Pierre M J; de Keizer, Bart

    2013-06-01

    The objective of this study was to identify patient characteristics positively and independently associated with I-iodide treatment failure in a large cohort of patients with Graves hyperthyroidism treated with either a calculated "standard" activity of 3.7 MBq/mL (0.1 mCi) or 7.4 MBq/mL (0.2 mCi) of thyroid volume. Data on 385 consecutive patients were prospectively collected. Clinical treatment outcome up to 1 year in relation to thyroid volume, 5- and 24-hour I uptake, 5/24-hour I uptake ratio, and the administered activity of radioiodine were analyzed. Overall treatment results were hypothyroidism in 46%, euthyroidism in 29%, and recurrent hyperthyroidism in 26% of patients. Thyroid volume (P = 0.000), 5/24-hour uptake ratio (P = 0.000), and 5- and 24-hour uptake alone (respectively, P = 0.000 and P = 0.002) were significantly associated with therapy outcome. Patients with a combination of a thyroid volume greater than 50 mL and a 5/24-hour uptake ratio 0.8 or greater showed treatment failure in 70% and 42% (respectively, 3.7 MBq/mL, n = 20; and 7.4 MBq/mL, n = 41).Thyroid volume and 5/24-hour uptake ratio were positively and independently associated with recurrent hyperthyroidism (respectively, odds ratio [OR], 5.3; 95% confidence interval [CI], 2.39-11.76; and OR, 2.97; 95% CI, 1.59-5.59). Higher activities of 7.4 MBq/mL I were associated with a lower risk of treatment failure (OR, 0.34; 95% CI, 0.18-0.62). Large thyroid volumes and high 5/24-hour uptake ratios are positively and independently associated with recurrent hyperthyroidism following I therapy in Graves hyperthyroidism. Higher success rates can be achieved when account is taken of these poor prognostic factors. In consequence, these patients should be treated with activities greater than 7.4 MBq/mL.

  11. Plasma uric acid and tumor volume are highly predictive of outcome in nasopharyngeal carcinoma patients receiving intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Lin, Hui; Lin, Huan-Xin; Ge, Nan; Wang, Hong-Zhi; Sun, Rui; Hu, Wei-Han

    2013-01-01

    The combined predictive value of plasma uric acid and primary tumor volume in nasopharyngeal carcinoma (NPC) patients receiving intensity modulated radiation therapy (IMRT) has not yet been determined. In this retrospective study, plasma uric acid level was measured after treatment in 130 histologically-proven NPC patients treated with IMRT. Tumor volume was calculated from treatment planning CT scans. Overall (OS), progression-free (PFS) and distant metastasis-free (DMFS) survival were compared using Kaplan-Meier analysis and the log rank test, and Cox multivariate and univariate regression models were created. Patients with a small tumor volume (<27 mL) had a significantly better DMFS, PFS and OS than patients with a large tumor volume. Patients with a high post-treatment plasma uric acid level (>301 μmol/L) had a better DMFS, PFS and OS than patients with a low post-treatment plasma uric acid level. Patients with a small tumor volume and high post-treatment plasma uric acid level had a favorable prognosis compared to patients with a large tumor volume and low post-treatment plasma uric acid level (7-year overall OS, 100% vs. 48.7%, P <0.001 and PFS, 100% vs. 69.5%, P <0.001). Post-treatment plasma uric acid level and pre-treatment tumor volume have predictive value for outcome in NPC patients receiving IMRT. NPC patients with a large tumor volume and low post-treatment plasma uric acid level may benefit from additional aggressive treatment after IMRT

  12. Implementation of machine learning for high-volume manufacturing metrology challenges (Conference Presentation)

    Science.gov (United States)

    Timoney, Padraig; Kagalwala, Taher; Reis, Edward; Lazkani, Houssam; Hurley, Jonathan; Liu, Haibo; Kang, Charles; Isbester, Paul; Yellai, Naren; Shifrin, Michael; Etzioni, Yoav

    2018-03-01

    In recent years, the combination of device scaling, complex 3D device architecture and tightening process tolerances have strained the capabilities of optical metrology tools to meet process needs. Two main categories of approaches have been taken to address the evolving process needs. In the first category, new hardware configurations are developed to provide more spectral sensitivity. Most of this category of work will enable next generation optical metrology tools to try to maintain pace with next generation process needs. In the second category, new innovative algorithms have been pursued to increase the value of the existing measurement signal. These algorithms aim to boost sensitivity to the measurement parameter of interest, while reducing the impact of other factors that contribute to signal variability but are not influenced by the process of interest. This paper will evaluate the suitability of machine learning to address high volume manufacturing metrology requirements in both front end of line (FEOL) and back end of line (BEOL) sectors from advanced technology nodes. In the FEOL sector, initial feasibility has been demonstrated to predict the fin CD values from an inline measurement using machine learning. In this study, OCD spectra were acquired after an etch process that occurs earlier in the process flow than where the inline CD is measured. The fin hard mask etch process is known to impact the downstream inline CD value. Figure 1 shows the correlation of predicted CD vs downstream inline CD measurement obtained after the training of the machine learning algorithm. For BEOL, machine learning is shown to provide an additional source of information in prediction of electrical resistance from structures that are not compatible for direct copper height measurement. Figure 2 compares the trench height correlation to electrical resistance (Rs) and the correlation of predicted Rs to the e-test Rs value for a far back end of line (FBEOL) metallization level

  13. Low-volume high-intensity swim training is superior to high-volume low-intensity training in relation to insulin sensitivity and glucose control in inactive middle-aged women.

    Science.gov (United States)

    Connolly, Luke J; Nordsborg, Nikolai B; Nyberg, Michael; Weihe, Pál; Krustrup, Peter; Mohr, Magni

    2016-10-01

    We tested the hypothesis that low-volume high-intensity swimming has a larger impact on insulin sensitivity and glucose control than high-volume low-intensity swimming in inactive premenopausal women with mild hypertension. Sixty-two untrained premenopausal women were randomised to an inactive control (n = 20; CON), a high-intensity low-volume (n = 21; HIT) or a low-intensity high-volume (n = 21; LIT) training group. During the 15-week intervention period, HIT performed 3 weekly 6-10 × 30-s all-out swimming intervals (average heart rate (HR) = 86 ± 3 % HRmax) interspersed by 2-min recovery periods and LIT swam continuously for 1 h at low intensity (average HR = 73 ± 3 % HRmax). Fasting blood samples were taken and an oral glucose tolerance test (OGTT) was conducted pre- and post-intervention. After HIT, resting plasma [insulin] was lowered (17 ± 34 %; P high-intensity intermittent swimming is an effective and time-efficient training strategy for improving insulin sensitivity, glucose control and biomarkers of vascular function in inactive, middle-aged mildly hypertensive women.

  14. Measuring the volume of caudate nucleus in healthy Chinese adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Ni Mingfei; Chen Nan; Wang Xing; Wu Jianlin; Li Kuncheng; Zhou Xin; Zhou Yan; Chen Lin

    2010-01-01

    Objective: To explore the normal range of the caudate nucleus' volume in Chinese adults of the Han nationality and provide morphological data for the construction of database for Chinese Standard Brain. Methods: This was a clinical multi-center study. One thousand Chinese healthy volunteers (age range =18 to 70) recruited from 16 hospitals were divided into 5 groups, i.e, Group A (age range = 18 to 30), B (age range =31 to 40), C (age range =41 to 50), D (age range =51 to 60), and E (age range =61 to 70). Each group contained 100 males and 100 females. All of the volunteers were scanned by MR using T 1 weighted three-dimensional magnetization prepared rapid acquisition gradient echo sequence. The volume of caudate was measured manually using 3D volume analysis software. The difference of volumes of the caudate between male and female were analyzed by independent sample t-test, and among age groups by ANOVA. Pearson's correlation coefficient was used to characterize the relationship between volumes and age. The differences of measurements between left and right caudate nucleus were analyzed by paired t test. Results: (1) The mean volume of bilateral caudate nucleus in healthy Chinese adults was (10.973± 1.647) cm 3 . The mean volume of the the male's left and right caudate nucleus were (5.656±0.860) and (5.671±0.855) cm 3 respectively,no significant differences were found between the volume of left and right caudate nucleus (t=1.230, P>0.05). The mean volume of the the female's left and right caudate nucleus were (5.287±0.774) and (5.331±0.766) cm 3 respectively, and the right's was larger than the left's with significant differences (t=3.999, P<0.01); (2) Pearson correlation analysis showed a significant negative correlation between the nucleus volume and age (male and female's, left and right) (r=-0.561, -0.568, -0.548, -0.552, P<0.05). Conclusion: With high-resolution MRI and 3D volumetric analytic software (Midob), the volume of the caudate nucleus can be

  15. Just-in-Time Training for High-Risk Low-Volume Therapies: An Approach to Ensure Patient Safety.

    Science.gov (United States)

    Helman, Stephanie; Lisanti, Amy Jo; Adams, Ann; Field, Cynthia; Davis, Katherine Finn

    2016-01-01

    High-risk low-volume therapies are those therapies that are practiced infrequently and yet carry an increased risk to patients because of their complexity. Staff nurses are required to competently manage these therapies to treat patients' unique needs and optimize outcomes; however, maintaining competence is challenging. This article describes implementation of Just-in-Time Training, which requires validation of minimum competency of bedside nurses managing high-risk low-volume therapies through direct observation of a return-demonstration competency checklist.

  16. Investigation on high efficiency volume Bragg gratings performances for spectrometry in space environment

    Science.gov (United States)

    Loicq, Jérôme; Stockman, Y.; Georges, Marc; Gaspar Venancio, Luis M.

    2017-11-01

    The special properties of Volume Bragg Gratings (VBGs) make them good candidates for spectrometry applications where high spectral resolution, low level of straylight and low polarisation sensitivity are required. Therefore it is of interest to assess the maturity and suitability of VBGs as enabling technology for future ESA missions with demanding requirements for spectrometry. The VBGs suitability for space application is being investigated in the frame of a project led by CSL and funded by the European Space Agency. The goal of this work is twofold: first the theoretical advantages and drawbacks of VBGs with respect to other technologies with identical functionalities are assessed, and second the performances of VBG samples in a representative space environment are experimentally evaluated. The performances of samples of two VBGs technologies, the Photo-Thermo-Refractive (PTR) glass and the DiChromated Gelatine (DCG), are assessed and compared in the Hα, O2-B and NIR bands. The tests are performed under vacuum condition combined with temperature cycling in the range of 200 K to 300K. A dedicated test bench experiment is designed to evaluate the impact of temperature on the spectral efficiency and to determine the optical wavefront error of the diffracted beam. Furthermore the diffraction efficiency degradation under gamma irradiation is assessed. Finally the straylight, the diffraction efficiency under conical incidence and the polarisation sensitivity is evaluated.

  17. Impact of Micro Silica on the properties of High Volume Fly Ash Concrete (HVFA)

    Science.gov (United States)

    Sripragadeesh, R.; Ramakrishnan, K.; Pugazhmani, G.; Ramasundram, S.; Muthu, D.; Venkatasubramanian, C.

    2017-07-01

    In the current situation, to overcome the difficulties of feasible construction, concrete made with various mixtures of Ordinary Portland Cement (OPC) and diverse mineral admixtures, is the wise choice for engineering construction. Mineral admixtures viz. Ground Granulated Blast Furnace Slag (GGBS), Meta kaolin (MK), Fly Ash (FA) and Silica Fume (SF) etc. are used as Supplementary Cementitious Materials (SCM) in binary and ternary blend cement system to enhance the mechanical and durability properties. Investigation on the effect of different replacement levels of OPC in M25 grade with FA + SF in ternary cement blend on the strength characteristics and beam behavior was studied. The OPC was partially replaced (by weight) with different combinations of SF (5%, 10%, 15%, 20% and 25%) and FA as 50% (High Volume Fly Ash - HVFA). The amount of FA addition is kept constant at 50% for all combinations. The compressive strength and tensile strength tests on cube and cylinder specimens, at 7 and 28 days were carried out. Based on the compressive strength results, optimum mix proportion was found out and flexural behaviour was studied for the optimum mix. It was found that all the mixes (FA + SF) showed improvement in compressive strength over that of the control mix and the mix with 50% FA + 10% SF has 20% increase over the control mix. The tensile strength was also increased over the control mix. Flexural behaviour also showed a significant improvement in the mix with FA and SF over the control mix.

  18. A rapid method for estimation of Pu-isotopes in urine samples using high volume centrifuge.

    Science.gov (United States)

    Kumar, Ranjeet; Rao, D D; Dubla, Rupali; Yadav, J R

    2017-07-01

    The conventional radio-analytical technique used for estimation of Pu-isotopes in urine samples involves anion exchange/TEVA column separation followed by alpha spectrometry. This sequence of analysis consumes nearly 3-4 days for completion. Many a times excreta analysis results are required urgently, particularly under repeat and incidental/emergency situations. Therefore, there is need to reduce the analysis time for the estimation of Pu-isotopes in bioassay samples. This paper gives the details of standardization of a rapid method for estimation of Pu-isotopes in urine samples using multi-purpose centrifuge, TEVA resin followed by alpha spectrometry. The rapid method involves oxidation of urine samples, co-precipitation of plutonium along with calcium phosphate followed by sample preparation using high volume centrifuge and separation of Pu using TEVA resin. Pu-fraction was electrodeposited and activity estimated using 236 Pu tracer recovery by alpha spectrometry. Ten routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 47-88% with a mean and standard deviation of 64.4% and 11.3% respectively. With this newly standardized technique, the whole analytical procedure is completed within 9h (one working day hour). Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Very Low Volume High-Intensity Interval Exercise Is More Effective in Young Than Old Women

    Directory of Open Access Journals (Sweden)

    Raulas Krusnauskas

    2018-01-01

    Full Text Available We investigated the acute neuromuscular and stress responses to three different high-intensity interval training sessions in young (age 19.5±1.3 years and older (age 65.7±2.8 years women. Cycling exercise comprised either 6 × 5 s or 3 × 30 s all-out, or 3 × 60 s submaximal, efforts each performed 5 weeks apart in randomized order. Peak and average power was higher in young than in older women and was largest during the 6 × 5 s strategy in both groups (p<0.05. The decrease in the ratio of torques evoked by 20 and 100 Hz electrical stimulation, representing low-frequency fatigue, was more evident after the 3 × 30 and 3 × 60 s than the 6 × 5 s bout in both groups and was larger in young than in older women (p<0.05. Both groups preferred 6 × 5 s cycling for further training. In conclusion, in young women, very low volume (6 × 5 s all-out exercise induces significant physiological stress and seems to be an effective means of training. For older women, longer exercise sessions (3 × 60 s are more stressful than shorter ones but are still tolerable psychologically.

  20. Replicable Interprofessional Competency Outcomes from High-Volume, Inter-Institutional, Interprofessional Simulation

    Directory of Open Access Journals (Sweden)

    Deborah Bambini

    2016-10-01

    Full Text Available There are significant limitations among the few prior studies that have examined the development and implementation of interprofessional education (IPE experiences to accommodate a high volume of students from several disciplines and from different institutions. The present study addressed these gaps by seeking to determine the extent to which a single, large, inter-institutional, and IPE simulation event improves student perceptions of the importance and relevance of IPE and simulation as a learning modality, whether there is a difference in students’ perceptions among disciplines, and whether the results are reproducible. A total of 290 medical, nursing, pharmacy, and physical therapy students participated in one of two large, inter-institutional, IPE simulation events. Measurements included student perceptions about their simulation experience using the Attitude Towards Teamwork in Training Undergoing Designed Educational Simulation (ATTITUDES Questionnaire and open-ended questions related to teamwork and communication. Results demonstrated a statistically significant improvement across all ATTITUDES subscales, while time management, role confusion, collaboration, and mutual support emerged as significant themes. Results of the present study indicate that a single IPE simulation event can reproducibly result in significant and educationally meaningful improvements in student perceptions towards teamwork, IPE, and simulation as a learning modality.

  1. Compression Behavior of Confined Columns with High-Volume Fly Ash Concrete

    Directory of Open Access Journals (Sweden)

    Sung-Won Yoo

    2017-01-01

    Full Text Available The use of fly ash in ordinary concrete provides practical benefits to concrete structures, such as a gain in long-term strength, reduced hydration heat, improved resistance to chloride, and enhanced workability. However, few studies with high-volume fly ash (HVFA concrete have been conducted that focus on the structural applications such as a column. Thus, there is a need to promote field applications of HVFA concrete as a sustainable construction material. To this end, this study investigated the compressive behavior of reinforced concrete columns that contain HVFA with a 50 percent replacement rate. Six columns were fabricated for this study. The study variables were the HVFA replacement rate, tied steel ratio, and tie steel spacing. The computed ultimate strength by the American Concrete Institute (ACI code conservatively predicted the measured values, and, thus, the existing equation in the ACI code is feasible for confined RC columns that contain HVFA. In addition, an analysis model was calibrated based on the experimental results and is recommended for predicting the stress-strain relationship of confined reinforced concrete columns that contain HVFA.

  2. Replicable Interprofessional Competency Outcomes from High-Volume, Inter-Institutional, Interprofessional Simulation.

    Science.gov (United States)

    Bambini, Deborah; Emery, Matthew; de Voest, Margaret; Meny, Lisa; Shoemaker, Michael J

    2016-10-25

    There are significant limitations among the few prior studies that have examined the development and implementation of interprofessional education (IPE) experiences to accommodate a high volume of students from several disciplines and from different institutions. The present study addressed these gaps by seeking to determine the extent to which a single, large, inter-institutional, and IPE simulation event improves student perceptions of the importance and relevance of IPE and simulation as a learning modality, whether there is a difference in students' perceptions among disciplines, and whether the results are reproducible. A total of 290 medical, nursing, pharmacy, and physical therapy students participated in one of two large, inter-institutional, IPE simulation events. Measurements included student perceptions about their simulation experience using the Attitude Towards Teamwork in Training Undergoing Designed Educational Simulation (ATTITUDES) Questionnaire and open-ended questions related to teamwork and communication. Results demonstrated a statistically significant improvement across all ATTITUDES subscales, while time management, role confusion, collaboration, and mutual support emerged as significant themes. Results of the present study indicate that a single IPE simulation event can reproducibly result in significant and educationally meaningful improvements in student perceptions towards teamwork, IPE, and simulation as a learning modality.

  3. Sustainable concrete with high volume GGBFS to build Masdar City in the UAE

    Directory of Open Access Journals (Sweden)

    Mohamed Elchalakani

    2014-01-01

    Full Text Available Masdar City (MC is leading the Middle East in the development of energy and resource efficient low-carbon construction in the United Arab Emirates (UAE. One of its major goals is to develop and specify materials and processes that will help reducing its environmental footprint through resource and energy conservation, as well as renewable energy generation. In 2010 MC announced on its website a prized-competition for the best proposal of “Sustainable Concrete” and “Lowest Carbon Footprint” to build MC with a total of two million cubic meter of concrete on 4 years period. This paper presents the experimental test results of 13 types of concrete mixes made with high volume of ground granulated blast furnace slag (GGBFS cement with 50%, 60%, 70% and 80% replacement of ordinary Portland cement (OPC to reduce the carbon emissions. A fly ash-blended mix made with 30% fly ash was also tested. The paper provides more information on the mix design parameter, full justification of CO2 footprint, and cost reduction for each concrete type. The hardened and plastic properties and durability test parameters for each mix are presented. The results show that the slag concrete mixes significantly reduce the carbon footprint and meet the requirements of MC. An economical mix with 80% GGBFS and 20% OPC was nominated for use in the future construction of MC with 154 kg/m3 carbon foot print.

  4. Mechanical properties of concrete containing a high volume of tire-rubber particles.

    Science.gov (United States)

    Khaloo, Ali R; Dehestani, M; Rahmatabadi, P

    2008-12-01

    Due to the increasingly serious environmental problems presented by waste tires, the feasibility of using elastic and flexible tire-rubber particles as aggregate in concrete is investigated in this study. Tire-rubber particles composed of tire chips, crumb rubber, and a combination of tire chips and crumb rubber, were used to replace mineral aggregates in concrete. These particles were used to replace 12.5%, 25%, 37.5%, and 50% of the total mineral aggregate's volume in concrete. Cylindrical shape concrete specimens 15 cm in diameter and 30 cm in height were fabricated and cured. The fresh rubberized concrete exhibited lower unit weight and acceptable workability compared to plain concrete. The results of a uniaxial compressive strain control test conducted on hardened concrete specimens indicate large reductions in the strength and tangential modulus of elasticity. A significant decrease in the brittle behavior of concrete with increasing rubber content is also demonstrated using nonlinearity indices. The maximum toughness index, indicating the post failure strength of concrete, occurs in concretes with 25% rubber content. Unlike plain concrete, the failure state in rubberized concrete occurs gently and uniformly, and does not cause any separation in the specimen. Crack width and its propagation velocity in rubberized concrete are lower than those of plain concrete. Ultrasonic analysis reveals large reductions in the ultrasonic modulus and high sound absorption for tire-rubber concrete.

  5. Automated high-volume aerosol sampling station for environmental radiation monitoring

    International Nuclear Information System (INIS)

    Toivonen, H.; Honkamaa, T.; Ilander, T.; Leppaenen, A.; Nikkinen, M.; Poellaenen, R.; Ylaetalo, S.

    1998-07-01

    An automated high-volume aerosol sampling station, known as CINDERELLA.STUK, for environmental radiation monitoring has been developed by the Radiation and Nuclear Safety Authority (STUK), Finland. The sample is collected on a glass fibre filter (attached into a cassette), the airflow through the filter is 800 m 3 /h at maximum. During the sampling, the filter is continuously monitored with Na(I) scintillation detectors. After the sampling, the large filter is automatically cut into 15 pieces that form a small sample and after ageing, the pile of filter pieces is moved onto an HPGe detector. These actions are performed automatically by a robot. The system is operated at a duty cycle of 1 d sampling, 1 d decay and 1 d counting. Minimum detectable concentrations of radionuclides in air are typically 1Ae10 x 10 -6 Bq/m 3 . The station is equipped with various sensors to reveal unauthorized admittance. These sensors can be monitored remotely in real time via Internet or telephone lines. The processes and operation of the station are monitored and partly controlled by computer. The present approach fulfils the requirements of CTBTO for aerosol monitoring. The concept suits well for nuclear material safeguards, too

  6. Identification of risk factors for post-endoscopic retrograde cholangiopancreatography pancreatitis in a high volume center.

    Directory of Open Access Journals (Sweden)

    Veit Phillip

    Full Text Available Pancreatitis is the most common complication of endoscopic retrograde cholangiopancreatography (ERCP. Several patients´ or procedure related risk factors for post-ERCP pancreatitis (PEP have been suggested. The aim of this study was to validate the risk factors for PEP in a high-volume center.All patients undergoing first time ERCP at a tertiary referral center between December 2010 and October 2013 were retrospectively included. PEP was defined according to the Atlanta Classification.344 patients were included in the final analysis. The risk to develop PEP was increased in patients with chronic pancreatitis (odds ratio 3.7 and after inadvertent cannulation of the pancreatic duct (odds ratio 2.2, which occurred in 26.5% of the patients. Inadvertent cannulation occurred significantly more frequently in patients with difficult cannulation of the papilla duodeni major (odds ratio 12.7; p<0.001. ERCP on call was associated with an increased risk for difficult cannulation (odds ratio 3.0.Inadvertent cannulation of the pancreatic duct is a procedure related risk factor for PEP. Measurements on preventing inadvertent cannulation of the pancreatic duct should be established and studies on prophylactic measurements should focus particularly on patients with inadvertent cannulation of the pancreatic duct.

  7. Identification of risk factors for post-endoscopic retrograde cholangiopancreatography pancreatitis in a high volume center.

    Science.gov (United States)

    Phillip, Veit; Schwab, Miriam; Haf, David; Algül, Hana

    2017-01-01

    Pancreatitis is the most common complication of endoscopic retrograde cholangiopancreatography (ERCP). Several patients´ or procedure related risk factors for post-ERCP pancreatitis (PEP) have been suggested. The aim of this study was to validate the risk factors for PEP in a high-volume center. All patients undergoing first time ERCP at a tertiary referral center between December 2010 and October 2013 were retrospectively included. PEP was defined according to the Atlanta Classification. 344 patients were included in the final analysis. The risk to develop PEP was increased in patients with chronic pancreatitis (odds ratio 3.7) and after inadvertent cannulation of the pancreatic duct (odds ratio 2.2), which occurred in 26.5% of the patients. Inadvertent cannulation occurred significantly more frequently in patients with difficult cannulation of the papilla duodeni major (odds ratio 12.7; passociated with an increased risk for difficult cannulation (odds ratio 3.0). Inadvertent cannulation of the pancreatic duct is a procedure related risk factor for PEP. Measurements on preventing inadvertent cannulation of the pancreatic duct should be established and studies on prophylactic measurements should focus particularly on patients with inadvertent cannulation of the pancreatic duct.

  8. Finite volume simulation of 2-D steady square lid driven cavity flow at high reynolds numbers

    Directory of Open Access Journals (Sweden)

    K. Yapici

    2013-12-01

    Full Text Available In this work, computer simulation results of steady incompressible flow in a 2-D square lid-driven cavity up to Reynolds number (Re 65000 are presented and compared with those of earlier studies. The governing flow equations are solved by using the finite volume approach. Quadratic upstream interpolation for convective kinematics (QUICK is used for the approximation of the convective terms in the flow equations. In the implementation of QUICK, the deferred correction technique is adopted. A non-uniform staggered grid arrangement of 768x768 is employed to discretize the flow geometry. Algebraic forms of the coupled flow equations are then solved through the iterative SIMPLE (Semi-Implicit Method for Pressure-Linked Equation algorithm. The outlined computational methodology allows one to meet the main objective of this work, which is to address the computational convergence and wiggled flow problems encountered at high Reynolds and Peclet (Pe numbers. Furthermore, after Re > 25000 additional vortexes appear at the bottom left and right corners that have not been observed in earlier studies.

  9. An exponential universal scaling law for the volume pinning force of high temperature superconductors

    International Nuclear Information System (INIS)

    Hampshire, D.P.

    1993-01-01

    The exponential magnetic field dependence of the critical current density (J c (B,T)) found in many high temperature superconductors, given by: J c (B,T) α(T)exp(-B/β(T)) where α(T) and β(T) are functions of temperature alone, necessarily implies a Universal Scaling Law for the volume pinning force (F p ) of the form: F p /F PMAX exp(+1).(B/β(T)).exp(-B/β(T)). If the Upper Critical Field is not explicitly measured but is artificially determined by smooth extrapolation of J c (B,T) to zero on a linear J c (B,T) vs B plot, this exponential scaling law can be closely approximated by the Kramer dependence given by: F p /F PMAX C.b p .(1-b) q where p = 0.5, q = 2, C ∼ 3.5 and b = B/B C2 (T). The implications for flux pinning studies are discussed. (orig.)

  10. Volume Attenuation and High Frequency Loss as Auditory Depth Cues in Stereoscopic 3D Cinema

    Science.gov (United States)

    Manolas, Christos; Pauletto, Sandra

    2014-09-01

    Assisted by the technological advances of the past decades, stereoscopic 3D (S3D) cinema is currently in the process of being established as a mainstream form of entertainment. The main focus of this collaborative effort is placed on the creation of immersive S3D visuals. However, with few exceptions, little attention has been given so far to the potential effect of the soundtrack on such environments. The potential of sound both as a means to enhance the impact of the S3D visual information and to expand the S3D cinematic world beyond the boundaries of the visuals is large. This article reports on our research into the possibilities of using auditory depth cues within the soundtrack as a means of affecting the perception of depth within cinematic S3D scenes. We study two main distance-related auditory cues: high-end frequency loss and overall volume attenuation. A series of experiments explored the effectiveness of these auditory cues. Results, although not conclusive, indicate that the studied auditory cues can influence the audience judgement of depth in cinematic 3D scenes, sometimes in unexpected ways. We conclude that 3D filmmaking can benefit from further studies on the effectiveness of specific sound design techniques to enhance S3D cinema.

  11. Survival rate in nasopharyngeal carcinoma improved by high caseload volume: a nationwide population-based study in Taiwan

    Directory of Open Access Journals (Sweden)

    Chou Pesus

    2011-08-01

    Full Text Available Abstract Background Positive correlation between caseload and outcome has previously been validated for several procedures and cancer treatments. However, there is no information linking caseload and outcome of nasopharyngeal carcinoma (NPC treatment. We used nationwide population-based data to examine the association between physician case volume and survival rates of patients with NPC. Methods Between 1998 and 2000, a total of 1225 patients were identified from the Taiwan National Health Insurance Research Database. Survival analysis, the Cox proportional hazards model, and propensity score were used to assess the relationship between 10-year survival rates and physician caseloads. Results As the caseload of individual physicians increased, unadjusted 10-year survival rates increased (p p = 0.001 after adjusting for comorbidities, hospital, and treatment modality. When analyzed by propensity score, the adjusted 10-year survival rate differed significantly between patients treated by high-volume physicians and patients treated by low/medium-volume physicians (75% vs. 61%; p Conclusions Our data confirm a positive volume-outcome relationship for NPC. After adjusting for differences in the case mix, our analysis found treatment of NPC by high-volume physicians improved 10-year survival rate.

  12. Measuring the volume of insula in healthy Chinese adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Qi Guangrui; Guo Yulin; Lai Yanbo; Gong Rui; Zhu Kai; Zhao Dan; Chen Nan; Wang Xing; Li Kuncheng; Zhuo Yan; Chen Lin

    2010-01-01

    volume (F= -0.361, -0.337, P 3 , the right were (8694 ± 1005), (8136 ± 1100), (8034 ± 910), (7496 ± 990), (6989 ± 932) mm 3 , there were significant differences among 5 groups between left and right insula volume (F= -0.490, -0.512, P<0.01). There was significant negative correlation between the volume and age( before standarizded: r= -0.361, -0.337, after standardized r=-0.490, -0.512, P<0.05). Before and after standardized, there was significant correlation between the volume of right and left insula and cerebral volume (r=0.470,0.459, P<0.05). Before and after standardized, there was significant correlation between the volume of right and left insula and weight(r =0.141,0.092,P<0.05). Conclusions: 1.5 T MR scanner has high resolution, for distinguishing the white matter from the gray matter, and provide morphological data of insula for the construction of database for Chinese Standard Brain. (authors)

  13. High Power Compact Single-Frequency Volume Bragg Er-Doped Fiber Laser, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal is based on successful results of Phase I project where it was shown that the use of volume Bragg gratings in PTR glass as selectors of transverse and...

  14. High procedure volume is strongly associated with improved survival after lung cancer surgery

    DEFF Research Database (Denmark)

    Lüchtenborg, Margreet; Riaz, Sharma P; Coupland, Victoria H

    2013-01-01

    Studies have reported an association between hospital volume and survival for non-small-cell lung cancer (NSCLC). We explored this association in England, accounting for case mix and propensity to resect....

  15. Transient regimes during high-temperature deformation of a bulk metallic glass: A free volume approach

    International Nuclear Information System (INIS)

    Bletry, M.; Guyot, P.; Brechet, Y.; Blandin, J.J.; Soubeyroux, J.L.

    2007-01-01

    The homogeneous deformation of a zirconium-based bulk metallic glass is investigated in the glass transition range. Compression and stress-relaxation tests have been conducted. The stress-strain curves are modeled in the framework of the free volume theory, including transient phenomena (overshoot and undershoot). This approach allows several physical parameters (activation volume, flow defect creation and relaxation coefficient) to be determined from a mechanical experiment. This model is able to rationalize the dependency of stress overshoot on relaxation time. It is shown that, due to the relationship between flow defect concentration and free volume model, it is impossible to determine the equilibrium flow defect concentration. However, the relative variation of flow defect is always the same, and all the model parameters depend on the equilibrium flow defect concentration. The methodology presented in this paper should, in the future, allow the consistency of the free volume model to be assessed

  16. Substance use and regional gray matter volume in individuals at high risk of psychosis

    OpenAIRE

    Stone, James; Bhattacharyya, Sagnik; Barker, Gareth J; McGuire, Philip K; Bhattacharyya, Sagnik

    2012-01-01

    Individuals with an at risk mental state (ARMS) are at greatly increased risk of developing a psychotic illness. Risk of transition to psychosis is associated with regionally reduced cortical gray matter volume. There has been considerable interest in the interaction between psychosis risk and substance use. In this study we investigate the relationship between alcohol, cannabis and nicotine use with gray matter volume in ARMS subjects and healthy volunteers. Twenty seven ARMS subjects and 27...

  17. Construction of a Liposome Dialyzer for preparation of high-value, small-volume liposome formulations

    OpenAIRE

    Adamala, Katarzyna; Engelhart, Aaron E.; Kamat, Neha P.; Jin, Lin; Szostak, Jack W.

    2015-01-01

    The liposome dialyzer is a small-volume equilibrium dialysis device, built from commercially available materials, that is designed for rapid exchange of small volumes of an extraliposomal reagent pool against a liposome preparation. The dialyzer is prepared by modification of commercially available dialysis cartridges and consists of a reactor with two 300 µL chambers and a 1.56 cm2 dialysis surface area. The dialyzer is prepared in three stages: 1) disassembly of dialysis cartridges to obtai...

  18. Design and evaluation of high-volume fly ash (HVFA) concrete mixes, report C : shear behavior of HVFA reinforced concrete.

    Science.gov (United States)

    2012-10-01

    Concrete is the most widely used man-made material on the planet. Unfortunately, producing Portland cement generates carbon dioxide (a greenhouse gas) at roughly a pound for pound ratio. High-volume fly ash (HVFA) concrete concrete with at least ...

  19. High-volume infiltration analgesia in total knee arthroplasty: a randomized, double-blind, placebo-controlled trial

    DEFF Research Database (Denmark)

    Andersen, L.O.; Husted, H.; Otte, K.S.

    2008-01-01

    with a detailed description of the infiltration technique. METHODS: In a randomized, double-blind, placebo-controlled trial in 12 patients undergoing bilateral knee arthroplasty, saline or high-volume (170 ml) ropivacaine (0.2%) with epinephrine was infiltrated around each knee, with repeated doses administered...

  20. Water stress from high-volume hydraulic fracturing potentially threatens aquatic biodiversity and ecosystem services in Arkansas, United States

    Science.gov (United States)

    Entrekin, Sally; Trainor, Anne; Saiers, James; Patterson, Lauren; Maloney, Kelly O.; Fargione, Joseph; Kiesecker, Joseph M.; Baruch-Mordo, Sharon; Konschnik, Katherine E.; Wiseman, Hannah; Nicot, Jean-Philippe; Ryan, Joseph N.

    2018-01-01

    Demand for high-volume, short duration water withdrawals could create water stress to aquatic organisms in Fayetteville Shale streams sourced for hydraulic fracturing fluids. We estimated potential water stress using permitted water withdrawal volumes and actual water withdrawals compared to monthly median, low, and high streamflows. Risk for biological stress was considered at 20% of long-term median and 10% of high- and low-flow thresholds. Future well build-out projections estimated potential for continued stress. Most water was permitted from small, free-flowing streams and “frack” ponds (dammed streams). Permitted 12-h pumping volumes exceeded median streamflow at 50% of withdrawal sites in June, when flows were low. Daily water usage, from operator disclosures, compared to median streamflow showed possible water stress in 7–51% of catchments from June–November, respectively. If 100% of produced water was recycled, per-well water use declined by 25%, reducing threshold exceedance by 10%. Future water stress was predicted to occur in fewer catchments important for drinking water and species of conservation concern due to the decline in new well installations and increased use of recycled water. Accessible and precise withdrawal and streamflow data are critical moving forward to assess and mitigate water stress in streams that experience high-volume withdrawals.

  1. Water Stress from High-Volume Hydraulic Fracturing Potentially Threatens Aquatic Biodiversity and Ecosystem Services in Arkansas, United States.

    Science.gov (United States)

    Entrekin, Sally; Trainor, Anne; Saiers, James; Patterson, Lauren; Maloney, Kelly; Fargione, Joseph; Kiesecker, Joseph; Baruch-Mordo, Sharon; Konschnik, Katherine; Wiseman, Hannah; Nicot, Jean-Philippe; Ryan, Joseph N

    2018-02-20

    Demand for high-volume, short duration water withdrawals could create water stress to aquatic organisms in Fayetteville Shale streams sourced for hydraulic fracturing fluids. We estimated potential water stress using permitted water withdrawal volumes and actual water withdrawals compared to monthly median, low, and high streamflows. Risk for biological stress was considered at 20% of long-term median and 10% of high- and low-flow thresholds. Future well build-out projections estimated potential for continued stress. Most water was permitted from small, free-flowing streams and "frack" ponds (dammed streams). Permitted 12-h pumping volumes exceeded median streamflow at 50% of withdrawal sites in June, when flows were low. Daily water usage, from operator disclosures, compared to median streamflow showed possible water stress in 7-51% of catchments from June-November, respectively. If 100% of produced water was recycled, per-well water use declined by 25%, reducing threshold exceedance by 10%. Future water stress was predicted to occur in fewer catchments important for drinking water and species of conservation concern due to the decline in new well installations and increased use of recycled water. Accessible and precise withdrawal and streamflow data are critical moving forward to assess and mitigate water stress in streams that experience high-volume withdrawals.

  2. 77 FR 28281 - Withdrawal of Revocation of TSCA Section 4 Testing Requirements for One High Production Volume...

    Science.gov (United States)

    2012-05-14

    ... Withdrawal of Revocation of TSCA Section 4 Testing Requirements for One High Production Volume Chemical...]amino]- (CAS No. 1324-76-1), also known as C.I. Pigment Blue 61. EPA received an adverse comment regarding C.I. Pigment Blue 61. This document withdraws the revocation of testing requirements for C.I...

  3. Transient analysis of electromagnetic wave interactions on high-contrast scatterers using volume electric field integral equation

    KAUST Repository

    Sayed, Sadeed Bin; Ulku, Huseyin Arda; Bagci, Hakan

    2014-01-01

    A marching on-in-time (MOT)-based time domain volume electric field integral equation (TD-VEFIE) solver is proposed for accurate and stable analysis of electromagnetic wave interactions on high-contrast scatterers. The stability is achieved using

  4. Quantifying volume loss from ice cliffs on debris-covered glaciers using high-resolution terrestrial and aerial photogrammetry

    NARCIS (Netherlands)

    Brun, Fanny; Buri, Pascal; Miles, Evan S.; Wagnon, Patrick; Steiner, J.F.; Berthier, Etienne; Ragettli, S.; Kraaijenbrink, P.D.A.; Immerzeel, W.W.; Pellicciotti, Francesca

    Mass losses originating from supraglacial ice cliffs at the lower tongues of debris-covered glaciers are a potentially large component of the mass balance, but have rarely been quantified. In this study, we develop a method to estimate ice cliff volume losses based on high-resolution topographic

  5. Exploring the relation between process design and efficiency in high-volume cataract pathways from a lean thinking perspective

    NARCIS (Netherlands)

    van Vliet, Ellen J.; Bredenhoff, E.; Bredenhoff, Eelco; Sermeus, Walter; Kop, Lucas M.; Sol, Johannes C.A.; van Harten, Willem H.

    2011-01-01

    Objective: To compare process designs of three high-volume cataract pathways in a lean thinking framework and to explore how efficiency in terms of lead times, hospital visits and costs is related to process design. Design: International retrospective comparative benchmark study with a mixed-method

  6. Volume of hospital is important for the prognosis of high-risk patients with nonvariceal upper gastrointestinal bleeding (NVUGIB).

    Science.gov (United States)

    Choi, Jin Woo; Jeon, Seong Woo; Kwon, Jung Gu; Lee, Dong Wook; Ha, Chang Yoon; Cho, Kwang Bum; Jang, Byung Ik; Park, Jung Bae; Park, Youn Sun

    2017-08-01

    Nonvariceal upper gastrointestinal bleeding (NVUGIB) is a potentially life-threatening hospital emergency requiring hemodynamic stabilization and resuscitation. This study is carried out to determine whether hospital volume can influence outcome in patients with NVUGIB. This is a retrospective study with a prospective cohort database (KCT 0000514. cris.nih.go.kr). Eight teaching hospitals were divided into two different groups: high-volume centers (HVC, ≥60 NVUGIB patients/year, four clinics) and low-volume centers (LVC, bleeding after treatment, re-bleeding, necessity for surgical/other retreatments, and death within 30 days. Similar baseline characters for patients were observed in both groups. There was a significant difference in the incidence of poor outcome between the HVC and LVC groups (9.06 vs. 13.69%, P = 0.014). The incidence rate of poor outcome in high-risk patients (Rockall score ≥8) in HVC was lower than that in high-risk patients in LVC (16.07 vs. 26.92%, P = 0.048); however, there was no significant difference in poor outcome in the lower-risk patients in either group (8.72 vs. 10.42%, P = 0.370). Significant correlation between hospital volume and outcome in NVUGIB patients was observed. Referral to HVC for the management of high-risk NVUGIB patients should be considered in clinical practice.

  7. Relationship between three cotton trash measurements: High Volume Instrumentation (HVI), Shirley Analyzer (SA), and Advanced Fiber Information System (AFIS)

    Science.gov (United States)

    Presence of non-lint materials (trashes) in commercial cotton bales at various amounts degrades the market values and further influences the end-use qualities. In order to ensure a fair trading, the USDA’s AMS has introduced the high volume instrument (HVI) measurement as a universal standard index....

  8. High-volume plasma exchange in patients with acute liver failure: An open randomised controlled trial.

    Science.gov (United States)

    Larsen, Fin Stolze; Schmidt, Lars Ebbe; Bernsmeier, Christine; Rasmussen, Allan; Isoniemi, Helena; Patel, Vishal C; Triantafyllou, Evangelos; Bernal, William; Auzinger, Georg; Shawcross, Debbie; Eefsen, Martin; Bjerring, Peter Nissen; Clemmesen, Jens Otto; Hockerstedt, Krister; Frederiksen, Hans-Jørgen; Hansen, Bent Adel; Antoniades, Charalambos G; Wendon, Julia

    2016-01-01

    Acute liver failure (ALF) often results in cardiovascular instability, renal failure, brain oedema and death either due to irreversible shock, cerebral herniation or development of multiple organ failure. High-volume plasma exchange (HVP), defined as exchange of 8-12 or 15% of ideal body weight with fresh frozen plasma in case series improves systemic, cerebral and splanchnic parameters. In this prospective, randomised, controlled, multicentre trial we randomly assigned 182 patients with ALF to receive either standard medical therapy (SMT; 90 patients) or SMT plus HVP for three days (92 patients). The baseline characteristics of the groups were similar. The primary endpoint was liver transplantation-free survival during hospital stay. Secondary-endpoints included survival after liver transplantation with or without HVP with intention-to-treat analysis. A proof-of-principle study evaluating the effect of HVP on the immune cell function was also undertaken. For the entire patient population, overall hospital survival was 58.7% for patients treated with HVP vs. 47.8% for the control group (hazard ratio (HR), with stratification for liver transplantation: 0.56; 95% confidence interval (CI), 0.36-0.86; p=0.0083). HVP prior to transplantation did not improve survival compared with patients who received SMT alone (CI 0.37 to 3.98; p=0.75). The incidence of severe adverse events was similar in the two groups. Systemic inflammatory response syndrome (SIRS) and sequential organ failure assessment (SOFA) scores fell in the treated group compared to control group, over the study period (pHVP improves outcome in patients with ALF by increasing liver transplant-free survival. This is attributable to attenuation of innate immune activation and amelioration of multi-organ dysfunction. Copyright © 2015 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  9. Self-healing of mechanically-loaded self consolidating concretes with high volumes of fly ash

    Energy Technology Data Exchange (ETDEWEB)

    Mustafa Sahmaran; Suleyman B. Keskin; Gozde Ozerkan; Ismail O. Yaman [University of Gaziantep, Gaziantep (Turkey). Department of Civil Engineering

    2008-11-15

    This article discusses the effects of self-healing on self consolidating concretes incorporating high volumes of fly ash (HVFA-SCC) when subjected to continuous water exposure. For this purpose, self consolidating concretes with fly ash replacement ratios of 0%, 35%, and 55% were prepared having a constant water-cementitious material ratio of 0.35. A uniaxial compression load was applied to generate microcracks in concrete where cylindrical specimens were pre-loaded up to 70% and 90% of the ultimate compressive load determined at 28 days. Later, the extent of damage was determined as percentage of loss in mechanical properties and percentage of increase in permeation properties. After pre-loading, concrete specimens were stored in water for a month and the mechanical and permeation properties are monitored at every two weeks. It was observed that HVFA-SCC mixtures initially lost 27% of their strength when pre-loaded up to 90% of their ultimate strength, and after 30 days of water curing that reduction was only 7%, indicating a substantial healing. On the other hand, for SCC specimens without fly ash that were pre-loaded to the same level, the loss in strength was initially 19%, and after a month of moist curing it was only 13%. Similar observations were also made on the permeation properties with greater effects. As the HVFA-SCCs studied have an important amount of unhydrated fly ash available in their microstructure, these observations are attributed to the self-healing of the pre-existing cracks, mainly by hydration of anhydrous fly ash particles on the crack surfaces.

  10. A high volume sampling system for isotope determination of volatile halocarbons and hydrocarbons

    Directory of Open Access Journals (Sweden)

    E. Bahlmann

    2011-10-01

    Full Text Available The isotopic composition of volatile organic compounds (VOCs can provide valuable information on their sources and fate not deducible from mixing ratios alone. In particular the reported carbon stable isotope ratios of chloromethane and bromomethane from different sources cover a δ13C-range of almost 100‰ making isotope ratios a very promising tool for studying the biogeochemistry of these compounds. So far, the determination of the isotopic composition of C1 and C2 halocarbons others than chloromethane is hampered by their low mixing ratios.

    In order to determine the carbon isotopic composition of C1 and C2 halocarbons with mixing ratios as low as 1 pptv (i a field suitable cryogenic high volume sampling system and (ii a chromatographic set up for processing these samples have been developed and validated. The sampling system was tested at two different sampling sites, an urban and a coastal location in Northern Germany. The average δ13C-values for bromomethane at the urban site were −42.9 ± 1.1‰ and agreed well with previously published results. But at the coastal site bromomethane was substantially enriched in 13C by almost 10‰. Less pronounced differences were observed for chlorodifluoromethane, 1,1,1-trichloroethane and chloromethane. We suggest that these differences are related to the turnover of these compounds in ocean surface waters. Furthermore we report first carbon isotope ratios for iodomethane (−40.4‰ to −79.8‰, bromoform (−13.8‰ to 22.9‰, and other halocarbons.

  11. High-volume image-guided injection for recalcitrant medial collateral ligament injuries of the knee

    International Nuclear Information System (INIS)

    Drumm, O.; Chan, O.; Malliaras, P.; Morrissey, D.; Maffulli, N.

    2014-01-01

    Aim: To evaluate the effectiveness of a novel injection technique in the management of recalcitrant medial collateral ligament (MCL) injuries of the knee. Materials and methods: The injection, comprising 10 ml local anaesthetic with 25–50 mg hydrocortisone, is directed beneath the periosteal attachment of the MCL. Twenty-eight patients who received the intervention were asked to complete a questionnaire, a visual analogue scale (VAS) and the International Knee Documentation Committee (IKDC) subjective knee form to quantify symptoms pre-injection and at follow-up. Data were assessed using descriptive statistics. Further analysis was conducted using the Wilcoxon signed-rank test and Fisher's exact test. Results: Sixty-eight percent (n = 19) of patients responded. Three patients were excluded according to the exclusion criteria. Of those studied, 37.5% (n = 6) were professional athletes. At follow-up, patients reported a mean improvement on the VAS of 75.5% (SD = 23.6). There was a significant improvement in IKDC scores (mean difference 42%, SD = 14.2) pre- and post-injection (Wilcoxon signed-rank test, p < 0.001). No residual symptoms were reported by 50% (n = 8) of patients, and a further 37.5% (n = 6) of patients had improved. Of those patients who played sport, two-thirds (n = 10) had returned to their previous level of sport at follow-up, including all of the professional athletes. Conclusion: Periosteal high-volume image-guided injection is a useful treatment for recalcitrant MCL injury. Results are encouraging, particularly amongst the professional athletes studied

  12. The role of equilibrium volume and magnetism on the stability of iron phases at high pressures.

    Science.gov (United States)

    Alnemrat, S; Hooper, J P; Vasiliev, I; Kiefer, B

    2014-01-29

    The present study provides new insights into the pressure dependence of magnetism by tracking the hybridization between crystal orbitals for pressures up to 600 GPa in the known hcp, bcc and fcc iron. The Birch-Murnaghan equation of state parameters are; bcc: V0 = 11.759 A(3)/atom, K0 = 177.72 GPa; hcp: V0 = 10.525 A(3)/atom, K0 = 295.16 GPa; and fcc: V0 = 10.682 A(3)/atom, K0 = 274.57 GPa. These parameters compare favorably with previous studies. Consistent with previous studies we find that the close-packed hcp and fcc phases are non-magnetic at pressures above 50 GPa and 60 GPa, respectively. The principal features of magnetism in iron are predicted to be invariant, at least up to ∼6% overextension of the equilibrium volume. Our results predict that magnetism for overextended fcc iron disappears via an intermediate spin state. This feature suggests that overextended lattices can be used to stabilize particular magnetic states. The analysis of the orbital hybridization shows that the magnetic bcc structure at high pressures is stabilized by splitting the majority and minority spin bands. The bcc phase is found to be magnetic at least up to 600 GPa; however, magnetism is insufficient to stabilize the bcc phase itself, at least at low temperatures. Finally, the analysis of the orbital contributions to the total energy provides evidence that non-magnetic hcp and fcc phases are likely more stable than bcc at core earth pressures.

  13. High-resolution surface and volume-based in vivo atlas of the serotonin system in the healthy brain

    DEFF Research Database (Denmark)

    Beliveau, Vincent; Ganz, Melanie; Svarer, Claus

    ) was performed using the FS PET pipeline [7] with a Multilinear Reference Tissue Model 2 [8] for all tracers, using a high-binding region for estimating k2', with the exception of [18F]Altanserin for which steady-state quantification (BPP) was used. The individual BP maps were then averaged for each tracer...... to create the final maps. Results: Surface and volume-based average BPND and BPP maps were created for all tracers (Figures 1-4). The availability of structural MRI enabled us to perform accurate normalization in both surface and volume, a quality previously absent from similar work [9]. These maps...

  14. Twenty-third water reactor safety information meeting: Volume 1, plenary session, high burnup fuel behavior, thermal hydraulic research. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Monteleone, S. [comp.] [Brookhaven National Lab., Upton, NY (United States)

    1996-03-01

    This three-volume report contains papers presented at the Twenty- Third Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, October 23-25, 1995. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Italy, Japan, Norway, Russia, Sweden, and Switzerland. This document, Volume 1, present topics on High Burnup Fuel Behavior, Thermal Hydraulic Research, and Plenary Session topics. Individual papers have been cataloged separately.

  15. Feasibility of disposal of high-level radioactive waste into the seabed. Volume 1: Overview of research and conclusions

    International Nuclear Information System (INIS)

    1988-01-01

    One of the options suggested for disposal of high-level radioactive waste resulting from the generation of nuclear power is burial beneath the deep ocean floor in geologically stable sediment formations which have no economic value. The 8-volume series provides an assessment of the technical feasibility and radiological safety of this disposal concept on the results obtained by ten years of co-operation and information exchange among the Member countries participating in the NEA Seabed Working Group. This volume provides an overview of the research and a summary of the results

  16. Twenty-third water reactor safety information meeting: Volume 1, plenary session, high burnup fuel behavior, thermal hydraulic research. Proceedings

    International Nuclear Information System (INIS)

    Monteleone, S.

    1996-03-01

    This three-volume report contains papers presented at the Twenty- Third Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, October 23-25, 1995. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Italy, Japan, Norway, Russia, Sweden, and Switzerland. This document, Volume 1, present topics on High Burnup Fuel Behavior, Thermal Hydraulic Research, and Plenary Session topics. Individual papers have been cataloged separately

  17. High Statistics Analysis using Anisotropic Clover Lattices: (IV) The Volume Dependence of the Light Hadron Masses

    Energy Technology Data Exchange (ETDEWEB)

    Beane, S R; Detmold, W; Lin, H W; Luu, T C; Orginos, K; Parreno, A; Savage, M J; Torok, A; Walker-Loud, A

    2011-07-01

    The volume dependence of the octet baryon masses and relations among them are explored with Lattice QCD. Calculations are performed with nf = 2 + 1 clover fermion discretization in four lattice volumes, with spatial extent L ? 2.0, 2.5, 3.0 and 4.0 fm, with an anisotropic lattice spacing of b_s ? 0.123 fm in the spatial direction, and b_t = b_s/3.5 in the time direction, and at a pion mass of m_\\pi ? 390 MeV. The typical precision of the ground-state baryon mass determination is volume dependence of the masses, the Gell-Mann Okubo mass-relation, and of other mass combinations. A comparison with the predictions of heavy baryon chiral perturbation theory is performed in both the SU(2)L ? SU(2)R and SU(3)L ? SU(3)R expansions. Predictions of the three-flavor expansion for the hadron masses are found to describe the observed volume dependences reasonably well. Further, the ?N? axial coupling constant is extracted from the volume dependence of the nucleon mass in the two-flavor expansion, with only small modifications in the three-flavor expansion from the inclusion of kaons and eta's. At a given value of m?L, the finite-volume contributions to the nucleon mass are predicted to be significantly smaller at m_\\pi ? 140 MeV than at m_\\pi ? 390 MeV due to a coefficient that scales as ? m_\\pi^3. This is relevant for the design of future ensembles of lattice gauge-field configurations. Finally, the volume dependence of the pion and kaon masses are analyzed with two-flavor and three-flavor chiral perturbation theory.

  18. Increased cartilage volume after injection of hyaluronic acid in osteoarthritis knee patients who underwent high tibial osteotomy.

    Science.gov (United States)

    Chareancholvanich, Keerati; Pornrattanamaneewong, Chaturong; Narkbunnam, Rapeepat

    2014-06-01

    High tibial osteotomy (HTO) is a surgical procedure used to correct abnormal mechanical loading of the knee joint; additionally, intra-articular hyaluronic acid injections have been shown to restore the viscoelastic properties of synovial fluid and balance abnormal biochemical processes. It was hypothesized that combining HTO with intra-articular hyaluronic acid injections would have benefit to improve the cartilage volume of knee joints. Forty patients with medial compartment knee osteoarthritis (OA) were randomly placed into 1 of 2 groups. The study group (n = 20) received 2 cycles (at 6-month intervals) of 5 weekly intra-articular hyaluronic acid injections after HTO operation. The control group (n = 20) did not receive any intra-articular injections after HTO surgery. Cartilage volume (primary outcome) was assessed by magnetic resonance imaging (MRI) pre-operatively and 1 year post-operatively. Treatment efficacy (secondary outcomes) was evaluated with the Western Ontario and McMaster Universities OA Index (WOMAC) and by the comparison of the total rescue medication (paracetamol/diclofenac) used (weeks 6, 12, 24, 48). MRI studies showed a significant increase in total cartilage volume (p = 0.033), lateral femoral cartilage volume (p = 0.044) and lateral tibial cartilage volume (p = 0.027) in the study group. Cartilage volume loss was detected at the lateral tibial plateau in the control group. There were significant improvements after surgery in both groups for all subscales of WOMAC scores (p hyaluronic acid injections may be beneficial for increasing total cartilage volume and preventing the loss of lateral tibiofemoral joint cartilage after HTO. Therapeutic study, Level I.

  19. Use of the SONET Score to Evaluate High Volume Emergency Department Overcrowding: A Prospective Derivation and Validation Study

    Directory of Open Access Journals (Sweden)

    Hao Wang

    2015-01-01

    Full Text Available Background. The accuracy and utility of current Emergency Department (ED crowding estimation tools remain uncertain in EDs with high annual volumes. We aimed at deriving a more accurate tool to evaluate overcrowding in a high volume ED setting and determine the association between ED overcrowding and patient care outcomes. Methods. A novel scoring tool (SONET: Severely overcrowded-Overcrowded-Not overcrowded Estimation Tool was developed and validated in two EDs with both annual volumes exceeding 100,000. Patient care outcomes including the number of left without being seen (LWBS patients, average length of ED stay, ED 72-hour returns, and mortality were compared under the different crowding statuses. Results. The total number of ED patients, the number of mechanically ventilated patients, and patient acuity levels were independent risk factors affecting ED overcrowding. SONET was derived and found to better differentiate severely overcrowded, overcrowded, and not overcrowded statuses with similar results validated externally. In addition, SONET scores correlated with increased length of ED stay, number of LWBS patients, and ED 72-hour returns. Conclusions. SONET might be a better fit to determine high volume ED overcrowding. ED overcrowding negatively impacts patient care operations and often produces poor patient perceptions of standardized care delivery.

  20. Combining high-resolution satellite images and altimetry to estimate the volume of small lakes

    Science.gov (United States)

    Baup, F.; Frappart, F.; Maubant, J.

    2014-05-01

    This study presents an approach to determining the volume of water in small lakes (manager of the lake. Three independent approaches are developed to estimate the lake volume and its temporal variability. The first two approaches (HRBV and ABV) are empirical and use synchronous ground measurements of the water volume and the satellite data. The results demonstrate that altimetry and imagery can be effectively and accurately used to monitor the temporal variations of the lake (R2ABV = 0.98, RMSEABV = 5%, R2HRBV = 0.90, and RMSEABV = 7.4%), assuming a time-varying triangular shape for the shore slope of the lake (this form is well adapted since it implies a difference inferior to 2% between the theoretical volume of the lake and the one estimated from bathymetry). The third method (AHRBVC) combines altimetry (to measure the lake level) and satellite images (of the lake surface) to estimate the volume changes of the lake and produces the best results (R2AHRBVC = 0.98) of the three methods, demonstrating the potential of future Sentinel and SWOT missions to monitor small lakes and reservoirs for agricultural and irrigation applications.

  1. Effect of total cementitious content on shear strength of high-volume fly ash concrete beams

    International Nuclear Information System (INIS)

    Arezoumandi, Mahdi; Volz, Jeffery S.; Ortega, Carlos A.; Myers, John J.

    2013-01-01

    Highlights: ► Existing design standards conservatively predicted the capacity of the HVFAC beams. ► In general, the HVFAC beams exceeded the code predicted shear strengths. ► The cementitious content did not have effect on the shear behavior of the HVFAC beams. - Abstract: The production of portland cement – the key ingredient in concrete – generates a significant amount of carbon dioxide. However, due to its incredible versatility, availability, and relatively low cost, concrete is the most consumed manmade material on the planet. One method of reducing concrete’s contribution to greenhouse gas emissions is the use of fly ash to replace a significant amount of the cement. This paper compares two experimental studies that were conducted to investigate the shear strength of full-scale beams constructed with high-volume fly ash concrete (HVFAC) – concrete with at least 50% of the cement replaced with fly ash. The primary difference between the two studies involved the amount of cementitious material, with one mix having a relatively high total cementitious content (502 kg/m 3 ) and the other mix having a relatively low total cementitious content (337 kg/m 3 ). Both mixes utilized a 70% replacement of portland cement with a Class C fly ash. Each of these experimental programs consisted of eight beams (six without shear reinforcing and two with shear reinforcing in the form of stirrups) with three different longitudinal reinforcement ratios. The beams were tested under a simply supported four-point loading condition. The experimental shear strengths of the beams were compared with both the shear provisions of selected standards (US, Australia, Canada, Europe, and Japan) and a shear database of conventional concrete (CC) specimens. Furthermore, statistical data analyses (both parametric and nonparametric) were performed to evaluate whether or not there is any statistically significant difference between the shear strength of both mixes. Results of these

  2. High order spectral volume and spectral difference methods on unstructured grids

    Science.gov (United States)

    Kannan, Ravishekar

    The spectral volume (SV) and the spectral difference (SD) methods were developed by Wang and Liu and their collaborators for conservation laws on unstructured grids. They were introduced to achieve high-order accuracy in an efficient manner. Recently, these methods were extended to three-dimensional systems and to the Navier Stokes equations. The simplicity and robustness of these methods have made them competitive against other higher order methods such as the discontinuous Galerkin and residual distribution methods. Although explicit TVD Runge-Kutta schemes for the temporal advancement are easy to implement, they suffer from small time step limited by the Courant-Friedrichs-Lewy (CFL) condition. When the polynomial order is high or when the grid is stretched due to complex geometries or boundary layers, the convergence rate of explicit schemes slows down rapidly. Solution strategies to remedy this problem include implicit methods and multigrid methods. A novel implicit lower-upper symmetric Gauss-Seidel (LU-SGS) relaxation method is employed as an iterative smoother. It is compared to the explicit TVD Runge-Kutta smoothers. For some p-multigrid calculations, combining implicit and explicit smoothers for different p-levels is also studied. The multigrid method considered is nonlinear and uses Full Approximation Scheme (FAS). An overall speed-up factor of up to 150 is obtained using a three-level p-multigrid LU-SGS approach in comparison with the single level explicit method for the Euler equations for the 3rd order SD method. A study of viscous flux formulations was carried out for the SV method. Three formulations were used to discretize the viscous fluxes: local discontinuous Galerkin (LDG), a penalty method and the 2nd method of Bassi and Rebay. Fourier analysis revealed some interesting advantages for the penalty method. These were implemented in the Navier Stokes solver. An implicit and p-multigrid method was also implemented for the above. An overall speed

  3. High-volume image quality assessment systems: tuning performance with an interactive data visualization tool

    Science.gov (United States)

    Bresnahan, Patricia A.; Pukinskis, Madeleine; Wiggins, Michael

    1999-03-01

    Image quality assessment systems differ greatly with respect to the number and types of mags they need to evaluate, and their overall architectures. Managers of these systems, however, all need to be able to tune and evaluate system performance, requirements often overlooked or under-designed during project planning. Performance tuning tools allow users to define acceptable quality standards for image features and attributes by adjusting parameter settings. Performance analysis tools allow users to evaluate and/or predict how well a system performs in a given parameter state. While image assessment algorithms are becoming quite sophisticated, duplicating or surpassing the human decision making process in their speed and reliability, they often require a greater investment in 'training' or fine tuning of parameters in order to achieve optimum performance. This process may involve the analysis of hundreds or thousands of images, generating a large database of files and statistics that can be difficult to sort through and interpret. Compounding the difficulty is the fact that personnel charged with tuning and maintaining the production system may not have the statistical or analytical background required for the task. Meanwhile, hardware innovations have greatly increased the volume of images that can be handled in a given time frame, magnifying the consequences of running a production site with an inadequately tuned system. In this paper, some general requirements for a performance evaluation and tuning data visualization system are discussed. A custom engineered solution to the tuning and evaluation problem is then presented, developed within the context of a high volume image quality assessment, data entry, OCR, and image archival system. A key factor influencing the design of the system was the context-dependent definition of image quality, as perceived by a human interpreter. This led to the development of a five-level, hierarchical approach to image quality

  4. Free volume model: High-temperature deformation of a Zr-based bulk metallic glass

    International Nuclear Information System (INIS)

    Bletry, M.; Guyot, P.; Blandin, J.J.; Soubeyroux, J.L.

    2006-01-01

    The homogeneous deformation of a zirconium-based bulk metallic glass is investigated in the glass transition region. Compression tests at different temperatures and strain rates have been conducted. The mechanical behavior is analyzed in the framework of the free volume model, taking into account the dependence of the flow defect concentration on deformation. The activation volume is evaluated and allows one to gather the viscosity data (for the different strain rates and temperatures) on a unique master curve. It is also shown that, due to the relation between flow defect concentration and free volume, it is not possible to deduce the equilibrium flow defect concentration directly from mechanical measurements. However, if this parameter is arbitrarily chosen, mechanical measurements give access to the other parameters of the model, these parameters for the alloy under investigation being of the same order of magnitude as those for other metallic glasses

  5. Effect of High-Temperature Curing Methods on the Compressive Strength Development of Concrete Containing High Volumes of Ground Granulated Blast-Furnace Slag

    Directory of Open Access Journals (Sweden)

    Wonsuk Jung

    2017-01-01

    Full Text Available This paper investigates the effect of the high-temperature curing methods on the compressive strength of concrete containing high volumes of ground granulated blast-furnace slag (GGBS. GGBS was used to replace Portland cement at a replacement ratio of 60% by binder mass. The high-temperature curing parameters used in this study were the delay period, temperature rise, peak temperature (PT, peak period, and temperature down. Test results demonstrate that the compressive strength of the samples with PTs of 65°C and 75°C was about 88% higher than that of the samples with a PT of 55°C after 1 day. According to this investigation, there might be optimum high-temperature curing conditions for preparing a concrete containing high volumes of GGBS, and incorporating GGBS into precast concrete mixes can be a very effective tool in increasing the applicability of this by-product.

  6. Substance use and regional gray matter volume in individuals at high risk of psychosis.

    Science.gov (United States)

    Stone, James M; Bhattacharyya, Sagnik; Barker, Gareth J; McGuire, Philip K

    2012-02-01

    Individuals with an at risk mental state (ARMS) are at greatly increased risk of developing a psychotic illness. Risk of transition to psychosis is associated with regionally reduced cortical gray matter volume. There has been considerable interest in the interaction between psychosis risk and substance use. In this study we investigate the relationship between alcohol, cannabis and nicotine use with gray matter volume in ARMS subjects and healthy volunteers. Twenty seven ARMS subjects and 27 healthy volunteers took part in the study. All subjects underwent volumetric MRI imaging. The relationship between regional gray matter volume and cannabis use, smoking, and alcohol use in controls and ARMS subjects was analysed using voxel-based morphometry. In any region where a significant relationship with drug was present, data were analysed to determine if there was any group difference in this relationship. Alcohol intake was inversely correlated with gray matter volume in cerebellum, cannabis intake was use was inversely correlated with gray matter volume in prefrontal cortex and tobacco intake was inversely correlated with gray matter volume in left temporal cortex. There were no significant interactions by group in any region. There is no evidence to support the hypothesis of increased susceptibility to harmful effects of drugs and alcohol on regional gray matter in ARMS subjects. However, alcohol, tobacco and cannabis at low to moderate intake may be associated with lower gray matter in both ARMS subjects and healthy volunteers-possibly representing low-level cortical damage or change in neural plasticity. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. European Registry of Carotid Artery Stenting: results from a prospective registry of eight high volume EUROPEAN institutions.

    Science.gov (United States)

    Stabile, Eugenio; Garg, Pallav; Cremonesi, Alberto; Bosiers, Marc; Reimers, Bernhard; Setacci, Carlo; Cao, Piergiorgio; Schmidt, Andrej; Sievert, Horst; Peeters, Patrick; Nikas, Dimitry; Werner, Martin; de Donato, Gianmarco; Parlani, Giambattista; Castriota, Fausto; Hornung, Marius; Mauri, Laura; Rubino, Paolo

    2012-08-01

    Carotid endarterectomy (CEA) is the standard revascularization therapy to prevent stroke in patients with carotid artery disease. Carotid artery stenting (CAS) could be considered a potential alternative in patients at high surgical risk. Recent clinical trials have challenged this concept due a relatively high incidence of post-CAS adverse events, which occurred in low volume centers. The aim of this study was to evaluate the outcomes associated with neuroprotected CAS in selected high volume centers. From January 2007 to December 2007, 1,611 patients underwent neuroprotected CAS in eight European Centers. For each patients, clinical, procedural, and one month follow-up data from all patients have been collected. An independent clinical events committee adjudicated the events. Overall in hospital death was 0.06% (one patient), whereas in-hospital stroke was 0.49% (eight patients). Between hospital discharge and 30 days three additional patients died (0.18%) and 10 patients experienced a stroke (0.67%). Overall 30 days mortality was 0.24% (four patients) and stroke incidence 1.12% (18 patients). The 30 day stroke/death rate was 1.36%. CAS is a reasonable alternative to CEA to treat carotid artery atherosclerosis in well-experienced high volume centers. These data suggest that future prospective trials comparing CAS and CEA outcomes should include only centers highly experienced in both treatment modalities. Copyright © 2012 Wiley Periodicals, Inc.

  8. Parallel Adaptive Mesh Refinement for High-Order Finite-Volume Schemes in Computational Fluid Dynamics

    Science.gov (United States)

    Schwing, Alan Michael

    For computational fluid dynamics, the governing equations are solved on a discretized domain of nodes, faces, and cells. The quality of the grid or mesh can be a driving source for error in the results. While refinement studies can help guide the creation of a mesh, grid quality is largely determined by user expertise and understanding of the flow physics. Adaptive mesh refinement is a technique for enriching the mesh during a simulation based on metrics for error, impact on important parameters, or location of important flow features. This can offload from the user some of the difficult and ambiguous decisions necessary when discretizing the domain. This work explores the implementation of adaptive mesh refinement in an implicit, unstructured, finite-volume solver. Consideration is made for applying modern computational techniques in the presence of hanging nodes and refined cells. The approach is developed to be independent of the flow solver in order to provide a path for augmenting existing codes. It is designed to be applicable for unsteady simulations and refinement and coarsening of the grid does not impact the conservatism of the underlying numerics. The effect on high-order numerical fluxes of fourth- and sixth-order are explored. Provided the criteria for refinement is appropriately selected, solutions obtained using adapted meshes have no additional error when compared to results obtained on traditional, unadapted meshes. In order to leverage large-scale computational resources common today, the methods are parallelized using MPI. Parallel performance is considered for several test problems in order to assess scalability of both adapted and unadapted grids. Dynamic repartitioning of the mesh during refinement is crucial for load balancing an evolving grid. Development of the methods outlined here depend on a dual-memory approach that is described in detail. Validation of the solver developed here against a number of motivating problems shows favorable

  9. Mi Carrera. Volume IV: Effective Career Planning with Hispanic High School Students.

    Science.gov (United States)

    Douglas, Denise, Ed.

    This curriculum guide, the fourth of a four-volume set that is intended to improve career and vocational guidance services to Spanish-speaking students in grades 9 through 12, is actually a collection of three different resources. The first section, "Group Activities: Intercambios," by Maria Garcia, is a model culturally based group counseling…

  10. Mechanical Properties and Shear Strengthening Capacity of High Volume Fly Ash-Cementitious Composite

    Science.gov (United States)

    Joseph, Aswin K.; Anand, K. B.

    2018-02-01

    This paper discusses development of Poly Vinyl Alcohol (PVA) fibre reinforced cementitious composites taking into account environmental sustainability. Composites with fly ash to cement ratios from 0 to 3 are investigated in this study. The mechanical properties of HVFA-cement composite are discussed in this paper at PVA fiber volume fraction maintained at 1% of total volume of composite. The optimum replacement of cement with fly ash was found to be 75%, i.e. fly ash to cement ratio (FA/C) of 3. The increase in fiber content from 1% to 2% showed better mechanical performance. A strain capacity of 2.38% was obtained for FA/C ratio of 3 with 2% volume fraction of fiber. With the objective of evaluating the performance of cementitious composites as a strengthening material in reinforced concrete beams, the beams deficient in shear capacity were strengthened with optimal mix having 2% volume fraction of fiber as the strengthening material and tested under four-point load. The reinforced concrete beams designed as shear deficient were loaded to failure and retrofitted with the composite in order to assess the efficiency as a repair material under shear.

  11. Final Report - Advanced MEA's for Enhanced Operating Conditions, Amenable to High Volume Manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Debe, Mark K.

    2007-09-30

    This report summarizes the work completed under a 3M/DOE contract directed at advancing the key fuel cell (FC) components most critical for overcoming the polymer electrolyte membrane fuel cell (PEMFC) performance, durability & cost barriers. This contract focused on the development of advanced ion exchange membranes & electrocatalysts for PEMFCs that will enable operation under ever more demanding automotive operating conditions & the use high volume compatible processes for their manufacture. Higher performing & more durable electrocatalysts must be developed for PEMFCs to meet the power density & lifetime hours required for FC vehicles. At the same time the amount of expensive Pt catalyst must be reduced to lower the MEA costs. While these two properties are met, the catalyst must be made resistant to multiple degradation mechanisms to reach necessary operating lifetimes. In this report, we present the work focused on the development of a completely new approach to PEMFC electrocatalyts, called nanostructured thin film (NSTF) catalysts. The carbon black supports are eliminated with this new approach which eliminates the carbon corrosion issue. The thin film nature of the catalyst significantly improves its robustness against dissolution & grain growth, preserving the surface area. Also, the activity of the NSTF for oxygen reduction is improved by over 500% compared to dispersed Pt catalyts. Finally, the process for fabricating the NSTF catalysts is consistent with high volume roll-good manufacturing & extremely flexible towards the introduction of new catalyst compositions & structures. This report documents the work done to develop new multi-element NSTF catalysts with properties that exceed pure Pt, that are optimized for use with the membranes discussed below, & advance the state-of-the-art towards meeting the DOE 2010 targets for PEMFC electrocatalysts. The work completed advances the understanding of the NSTF catalyst technology, identifies new NSTF

  12. High-volume ovarian cancer care: survival impact and disparities in access for advanced-stage disease.

    Science.gov (United States)

    Bristow, Robert E; Chang, Jenny; Ziogas, Argyrios; Randall, Leslie M; Anton-Culver, Hoda

    2014-02-01

    To characterize the impact of hospital and physician ovarian cancer case volume on survival for advanced-stage disease and investigate socio-demographic variables associated with access to high-volume providers. Consecutive patients with stage IIIC/IV epithelial ovarian cancer (1/1/96-12/31/06) were identified from the California Cancer Registry. Disease-specific survival analysis was performed using Cox-proportional hazards model. Multivariate logistic regression analyses were used to evaluate for differences in access to high-volume hospitals (HVH) (≥20 cases/year), high-volume physicians (HVP) (≥10 cases/year), and cross-tabulations of high- or low-volume hospital (LVH) and physician (LVP) according to socio-demographic variables. A total of 11,865 patients were identified. The median ovarian cancer-specific survival for all patients was 28.2 months, and on multivariate analysis the HVH/HVP provider combination (HR = 1.00) was associated with superior ovarian cancer-specific survival compared to LVH/LVP (HR = 1.31, 95%CI = 1.16-1.49). Overall, 2119 patients (17.9%) were cared for at HVHs, and 1791 patients (15.1%) were treated by HVPs. Only 4.3% of patients received care from HVH/HVP, while 53.1% of patients were treated by LVH/LVP. Both race and socio-demographic characteristics were independently associated with an increased likelihood of being cared for by the LVH/LVP combination and included: Hispanic race (OR = 1.72, 95%CI = 1.22-2.42), Asian/Pacific Islander race (OR = 1.57, 95%CI = 1.07-2.32), Medicaid insurance (OR = 2.51, 95%CI = 1.46-4.30), and low socioeconomic status (OR = 2.84, 95%CI = 1.90-4.23). Among patients with advanced-stage ovarian cancer, the provider combination of HVH/HVP is an independent predictor of improved disease-specific survival. Access to high-volume ovarian cancer providers is limited, and barriers are more pronounced for patients with low socioeconomic status, Medicaid insurance, and racial minorities. Copyright © 2013

  13. Measuring the volume of the hippocampus in healthy Chinese adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Zhang Yong; Chen Nan; Wang Xing; Li Kuncheng; Zhuo Yan; Chen Lin

    2010-01-01

    Objective: To measure the volume of hippocampal formation (HPF) in healthy Chinese Han adults and provide database for researching on a variety of diseases associated with alteration of hippocampal structure. Methods: This is a clinical multi-center study. One thousand Chinese healthy volunteers (age range=18 to 70) recruited from 15 hospitals were divided into 5 groups, i. e., Group A (age range=18 to 30), B (age range=31 to 40), C (age range =41 to 50), D (age range =51 to 60), and E (age range = 61 to 70). Each group contained 100 males and 100 females. All of the volunteers were scanned by MR using T 1 weighted three-dimensional magnetization prepared rapid acquisition gradient echo sequence. The margin of HPF were outlined manually for each side. Using multiple linear regression, relationships between hippocampal volume and sex, age, weight and height were analyzed respectively. Independent two sample t test was used to study the differences between male and female and between left and right. The differences of hippocampal volume among age groups were analyzed by ANOVA. Results: Hippocampal volume for left and right side were (4752±659) and (5032±660) mm 3 respectively. The volume of HPF is significant correlated with gender and age, but without relevance to height and weight (left and right r=0.283,0.311, F=30.127,37.050,P 3 respectively for men, and (4647±624) and (4904±630) mm 3 for women. The right hippocampal volume was larger than the left (t=7.030,6.696, P 3 respectively, while the volumes of the fight hippocampus were (5340± 647), (5276±582), (5264±620), (5133±661), (4894±699) mm 3 respectively. Among age groups, the differences were statistically significant (left and right F=5.737,7.607, P 0.05). There was no significant difference of hippocampal among different groups in women (P>0.05). Conclusions: With high-resolution MRI, the volume of the HPF was accurately measured, so as to provide the basic data for research of the hippocampus

  14. Containment at the Source during Waste Volume Reduction of Large Radioactive Components Using Oxylance High-Temperature Cutting Equipment - 13595

    International Nuclear Information System (INIS)

    Keeney, G. Neil

    2013-01-01

    As a waste-volume reduction and management technique, highly contaminated Control Element Drive Mechanism (CEDM) housings were severed from the Reactor Pressure Vessel Head (RPVH) inside the San Onofre Unit 2 primary containment utilizing Oxylance high-temperature cutting equipment and techniques. Presented are relevant data concerning: - Radiological profiles of the RPVH and individual CEDMs; - Design overviews of the engineering controls and the specialized confinement housings; - Utilization of specialized shielding; - Observations of apparent metallurgical-contamination coalescence phenomena at high temperatures resulting in positive control over loose-surface contamination conditions; - General results of radiological and industrial hygiene air sampling and monitoring; - Collective dose and personnel contamination event statistics; - Lessons learned. (author)

  15. Immobilization of defense high-level waste: an assessment of technological strategies and potential regulatory goals. Volume I

    International Nuclear Information System (INIS)

    1979-06-01

    An investigation was made of the high-level radioactive waste immobilization technology programs in the U.S. and Europe, and of the associated regulatory programs and waste management perspectives in the countries studied. Purpose was to assess the ability of those programs to satisfy DOE waste management needs and U.S. regulatory requirements. This volume includes: introduction, immobilization strategies in the context of waste isolation program needs, high-level waste management as an integrated system, regulatory goals, engineered-barrier characteristics, barrier technology, high-level waste disposal programs, analysis of HLW immobilization technology in the context of policy and regulatory requirements, and waste immobilization program option

  16. Containment at the Source during Waste Volume Reduction of Large Radioactive Components Using Oxylance High-Temperature Cutting Equipment - 13595

    Energy Technology Data Exchange (ETDEWEB)

    Keeney, G. Neil [Health Physicist, HazMat CATS, LLC (United States)

    2013-07-01

    As a waste-volume reduction and management technique, highly contaminated Control Element Drive Mechanism (CEDM) housings were severed from the Reactor Pressure Vessel Head (RPVH) inside the San Onofre Unit 2 primary containment utilizing Oxylance high-temperature cutting equipment and techniques. Presented are relevant data concerning: - Radiological profiles of the RPVH and individual CEDMs; - Design overviews of the engineering controls and the specialized confinement housings; - Utilization of specialized shielding; - Observations of apparent metallurgical-contamination coalescence phenomena at high temperatures resulting in positive control over loose-surface contamination conditions; - General results of radiological and industrial hygiene air sampling and monitoring; - Collective dose and personnel contamination event statistics; - Lessons learned. (author)

  17. Cerebral gray matter volume losses in essential tremor: A case-control study using high resolution tissue probability maps.

    Science.gov (United States)

    Cameron, Eric; Dyke, Jonathan P; Hernandez, Nora; Louis, Elan D; Dydak, Ulrike

    2018-03-10

    Essential tremor (ET) is increasingly recognized as a multi-dimensional disorder with both motor and non-motor features. For this reason, imaging studies are more broadly examining regions outside the cerebellar motor loop. Reliable detection of cerebral gray matter (GM) atrophy requires optimized processing, adapted to high-resolution magnetic resonance imaging (MRI). We investigated cerebral GM volume loss in ET cases using automated segmentation of MRI T1-weighted images. MRI was acquired on 47 ET cases and 36 controls. Automated segmentation and voxel-wise comparisons of volume were performed using Statistical Parametric Mapping (SPM) software. To improve upon standard protocols, the high-resolution International Consortium for Brain Mapping (ICBM) 2009a atlas and tissue probability maps were used to process each subject image. Group comparisons were performed: all ET vs. Controls, ET with head tremor (ETH) vs. Controls, and severe ET vs. An analysis of variance (ANOVA) was performed between ET with and without head tremor and controls. Age, sex, and Montreal Cognitive Assessment (MoCA) score were regressed out from each comparison. We were able to consistently identify regions of cerebral GM volume loss in ET and in ET subgroups in the posterior insula, superior temporal gyri, cingulate cortex, inferior frontal gyri and other occipital and parietal regions. There were no significant increases in GM volume in ET in any comparisons with controls. This study, which uses improved methodologies, provides evidence that GM volume loss in ET is present beyond the cerebellum, and in fact, is widespread throughout the cerebrum as well. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Disposable photonic integrated circuits for evanescent wave sensors by ultra-high volume roll-to-roll method.

    Science.gov (United States)

    Aikio, Sanna; Hiltunen, Jussi; Hiitola-Keinänen, Johanna; Hiltunen, Marianne; Kontturi, Ville; Siitonen, Samuli; Puustinen, Jarkko; Karioja, Pentti

    2016-02-08

    Flexible photonic integrated circuit technology is an emerging field expanding the usage possibilities of photonics, particularly in sensor applications, by enabling the realization of conformable devices and introduction of new alternative production methods. Here, we demonstrate that disposable polymeric photonic integrated circuit devices can be produced in lengths of hundreds of meters by ultra-high volume roll-to-roll methods on a flexible carrier. Attenuation properties of hundreds of individual devices were measured confirming that waveguides with good and repeatable performance were fabricated. We also demonstrate the applicability of the devices for the evanescent wave sensing of ambient refractive index. The production of integrated photonic devices using ultra-high volume fabrication, in a similar manner as paper is produced, may inherently expand methods of manufacturing low-cost disposable photonic integrated circuits for a wide range of sensor applications.

  19. Effect of uncertainty in pore volumes on the uncertainty in amount adsorbed at high-pressures on activated carbon cloth

    International Nuclear Information System (INIS)

    Pendleton, Ph.; Badalyan, A.

    2005-01-01

    Activated carbon cloth (ACC) is a good adsorbent for high rate adsorption of volatile organic carbons [1] and as a storage media for methane [2]. It has been shown [2] that the capacity of ACC to adsorb methane, in the first instance, depends on its micropore volume. One way of increasing this storage capacity is to increase micropore volume [3]. Therefore, the uncertainty in the determination of ACC micropore volume becomes a very important factor, since it affects the uncertainty of amount adsorbed at high-pressures, which usually accompany storage of methane on ACC. Recently, we developed a method for the calculation of experimental uncertainty in micropore volume using low pressure nitrogen adsorption data at 77 K for FM1/250 ACC (ex. Calgon, USA). We tested several cubic equations of state (EOS) and multiple parameter (EOS) to determine the amount of high-pressure nitrogen adsorbed, and compared these data with amounts calculated via interpolated NIST density data. The amount adsorbed calculated from interpolated NIST density data exhibit the lowest propagated combined uncertainty. Values of relative combined standard uncertainty for FM1/250 calculated using a weighted, mean-least-squares method applied to the low-pressure nitrogen adsorption data (Fig. 1) gave 3.52% for the primary micropore volume and 1.63% for the total micropore volume. Our equipment allows the same sample to be exposed to nitrogen (and other gases) at pressures from 10 -4 Pa to 17-MPa in the temperature range from 176 to 252 K. The maximum uptake of nitrogen was 356-mmol/g at 201.92 K and 15.8-MPa (Fig. 2). The delivery capacity of ACC is determined by the amount of adsorbed gas recovered when the pressure is reduced from that for maximum adsorption to 0.1-MPa [2]. In this regard, the total micropore volume becomes an important parameter in determining the amount of gas delivered during desorption. In the present paper we will discuss the effect of uncertainty in micropore volume

  20. Highly efficient volume hologram multiplexing in thick dye-doped jelly-like gelatin.

    Science.gov (United States)

    Katarkevich, Vasili M; Rubinov, Anatoli N; Efendiev, Terlan Sh

    2014-08-01

    Dye-doped jelly-like gelatin is a thick-layer self-developing photosensitive medium that allows single and multiplexed volume phase holograms to be successfully recorded using pulsed laser radiation. In this Letter, we present a method for multiplexed recording of volume holograms in a dye-doped jelly-like gelatin, which provides significant increase in their diffraction efficiency. The method is based on the recovery of the photobleached dye molecule concentration in the hologram recording zone of gel, thanks to molecule diffusion from other unexposed gel areas. As an example, an optical recording of a multiplexed hologram consisting of three superimposed Bragg gratings with mean values of the diffraction efficiency and angular selectivity of ∼75% and ∼21', respectively, is demonstrated by using the proposed method.

  1. Measuring the volume of temporal lobe in healthy Chinese adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Jia Kefeng; Wu Li; Duan Hui; Han Dan; Chen Nan; Li Kuncheng

    2010-01-01

    Objective: To explore the morphological features of temporal lobe of healthy Chinese Han adults on the high-resolution MRI and provide morphological data of temporal lobe for the construction of database for Chinese Standard Brain. Methods: This is a clinical multi-center study. Three hundred healthy Chinese volunteers (male 150, and female 150) recruited from 15 hospitals were divided equally into five groups according to their age, i.e., 18-30 (Group A), 31-40 (Group B), 41-50 (Group C), 51- 60(Group D), 61-70(Group E). All subjects were scanned using T 1 WI 3D MPRAGE sequence and volumes of standardized temporal lobe were collected. The bilateral volumes of standardized temporal lobe were compared by variance analysis between male and female subjects and among five age groups. Results: The mean volumes of left and right temporal lobe were (97 126±15 703) mm 3 and (97 015 ± 15 545) mm 3 respectively for men, and (95 123 ± 14 564) mm 3 and (96 423 ± 13 407) mm 3 for women. The difference temporal lobe volume between male and female wasn't significant on the same side (F=1.336, 0.127, P= 0.249, 0.722). The left temporal lobe volumes of Group A-E were (93 873±13 351), (95 566± 11 964), (10 1890 ± 14 511), (93 972 ± 14 050) and (95 636 ± 19 864) mm 3 respectively, and those on the right side were (93 409 ± 10 984), (98 158 ± 16 392), (102 079 ± 15 112), (95 448 ± 11 123) and (94 658 ± 16 928) mm 3 . There were significant differences among 5 groups between left and right temporal lobe volume(F=2.940, 3.514, P=0.021, 0.008). Further pairwise comparison revealed that left and right temporal lobe volume in Group C is higher than those of Group A and D (P 0.05). Conclusion: High-resolution MRI could offer detailed images and precise morphological data of temporal lobe, which provides morphological data of temporal lobe for the construction of database for Chinese Standard Brain. (authors)

  2. High-temperature vacant lattice site formation in solids and free volumes in melts studied by positron lifetime measurements

    Science.gov (United States)

    Schaefer, H.-E.

    1991-05-01

    In the present paper a concise review is given of the application of positron lifetime measurements to the study of high-temperature vacancies in intermetallic compounds (F 76.3Al 23.7), in metal oxides (NiO), in elemental semiconductors (Si, Ge), and of the oxygen loss or uptake in YBa 2Cu 3O 7-δ. Investigations of free volumes in elemental melts (Al, In, Ge) are included.

  3. High-temperature vacant lattice site formation in solids and free volumes in melts studied by positron lifetime measurements

    International Nuclear Information System (INIS)

    Schaefer, H.E.

    1991-01-01

    In the present paper a concise review is given of the application of positron lifetime measurements to the study of high-temperature vacancies in intermetallic compounds (F 76.3 Al 23.7 ), in metal oxides (NiO), in elemntal semiconductors (Si, Ge), and of the oxygen loss or uptake in YBa 2 Cu 3 O 7-δ . Investigations of free volumes in elemental melts (Al, In, Ge) are included. (orig.)

  4. Hippocampus and amygdala volumes in children and young adults at high-risk of schizophrenia: research synthesis.

    Science.gov (United States)

    Ganzola, Rossana; Maziade, Michel; Duchesne, Simon

    2014-06-01

    Studies have reported hippocampal and amygdala volume abnormalities in schizophrenic patients. It is necessary to explore the potential for these structures as early disease markers in subjects at high risk (HR) of schizophrenia. We performed a review of 29 magnetic resonance imaging (MRI) studies measuring hippocampal and amygdala volumes in subjects at HR for schizophrenia. We reclassified subjects in 3 new HR categories: presence of only risk symptoms (psychotic moderate symptoms), presence of only risk factors (genetic, developmental or environmental), and presence of combined risk symptoms/factors. Hippocampal volume reductions were detected in subjects with first episode (FE) of psychosis, in all young adults and in adolescents at HR of schizophrenia. The loss of tissue was mainly located in the posterior part of hippocampus and the right side seems more vulnerable in young adults with only risk symptoms. Instead, the anterior sector seems more involved in HR subjects with genetic risks. Abnormal amygdala volumes were found in FE subjects, in children with combined risk symptoms/factors and in older subjects using different inclusion criteria, but not in young adults. Hippocampal and amygdala abnormalities may be present before schizophrenia onset. Further studies should be conducted to clarify whether these abnormalities are causally or effectually related to neurodevelopment. Shape analysis could clarify the impact of environmental, genetic, and developmental factors on the medial temporal structures during the evolution of this disease. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Excess Molar Volumes of the Octane-1-Chlorobutane System at High Pressures and Elevated Temperatures

    Czech Academy of Sciences Publication Activity Database

    Morávková, Lenka; Linek, Jan

    2002-01-01

    Roč. 56, č. 6 (2002), s. 374-377 ISSN 0366-6352. [International Conference of Slovak Society of Chemical Engineering /29./. Tatranské Matliare, 27.05.2002-31.05.2002] R&D Projects: GA ČR GA203/00/0600 Keywords : densities * excess volumes * mixtures Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 0.336, year: 2002

  6. Excess Molar Volumes of the Heptane ů 1-Chloropentane System at High Pressures and Elevated Temperatures

    Czech Academy of Sciences Publication Activity Database

    Linek, Jan; Morávková, Lenka

    2001-01-01

    Roč. 55, č. 6 (2001), s. 382-385 ISSN 0366-6352. [28th International Conference of SSCHE. Tatranské Matliare, 21.05.2001-25.05.2001] R&D Projects: GA ČR GA203/00/0600 Institutional research plan: CEZ:AV0Z4072921 Keywords : measurement * excess molar volumes * apparatus Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 0.349, year: 2001

  7. Perception of alcohol strength impaired by low and high volume distraction

    OpenAIRE

    Stafford, Lorenzo; Agobiani, E.; Fernandes, M.

    2013-01-01

    Recent research demonstrated impaired discrimination of alcohol strength under distracting conditions. The present study aimed to extend this by examining the effects of distraction volume on alcohol perception. In the study here (between subjects design, 34 females/20 males), participants completed standardized taste and olfactory tests, followed by a taste test of alcoholic beverages (0, 1.9, 3.9, 5.6 and 7.5pct abv) in a randomly allocated distractive or control condition [Control, Shadow ...

  8. Construction of a Liposome Dialyzer for preparation of high-value, small-volume liposome formulations

    Science.gov (United States)

    Adamala, Katarzyna; Engelhart, Aaron E.; Kamat, Neha P.; Jin, Lin; Szostak, Jack W.

    2016-01-01

    The liposome dialyzer is a small-volume equilibrium dialysis device, built from commercially available materials, that is designed for rapid exchange of small volumes of an extraliposomal reagent pool against a liposome preparation. The dialyzer is prepared by modification of commercially available dialysis cartridges and consists of a reactor with two 300 µL chambers and a 1.56 cm2 dialysis surface area. The dialyzer is prepared in three stages: 1) disassembly of dialysis cartridges to obtain required parts; 2) assembly of the dialyzer; and 3) sealing the dialyzer with epoxy. Preparation of the dialyser takes about 1.5 h, not including overnight epoxy curing. Each round of dialysis takes 1–24 h, depending on the analyte and membrane employed. We previously used the dialyzer for small-volume nonenzymatic RNA synthesis reactions inside fatty acid vesicles. In this protocol, we demonstrate other applications, including removal of unencapsulated calcein from vesicles, remote loading, and vesicle microscopy. PMID:26020615

  9. Evolving progress in oncologic and operative outcomes for esophageal and junctional cancer: lessons from the experience of a high-volume center.

    LENUS (Irish Health Repository)

    Reynolds, John V

    2012-05-01

    Modern series from high-volume esophageal centers report an approximate 40% 5-year survival in patients treated with curative intent and postoperative mortality rates of less than 4%. An objective analysis of factors that underpin current benchmarks within high-volume centers has not been performed.

  10. ACUTE EFFECTS OF STATIC STRETCHING, DYNAMIC EXERCISES, AND HIGH VOLUME UPPER EXTREMITY PLYOMETRIC ACTIVITY ON TENNIS SERVE PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Ertugrul Gelen

    2012-12-01

    Full Text Available The purpose of this study was to compare the acute effects of static stretching; dynamic exercises and high volume upper extremity plyometric activity on tennis serve performance. Twenty-six elite young tennis players (15.1 ± 4.2 years, 167.9 ± 5.8 cm and 61.6 ± 8.1 kg performed 4 different warm-up (WU routines in a random order on non-consecutive days. The WU methods consisted of traditional WU (jogging, rally and serve practice (TRAD; traditional WU and static stretching (TRSS; traditional WU and dynamic exercise (TRDE; and traditional WU and high volume upper extremity plyometric activity (TRPLYP. Following each WU session, subjects were tested on a tennis serve ball speed test. TRAD, TRSS, TRDE and TRPLYO were compared by repeated measurement analyses of variance and post-hoc comparisons. In this study a 1 to 3 percent increase in tennis serve ball speed was recorded in TRDE and TRPLYO when compared to TRAD (p 0.05. ICCs for ball speed showed strong reliability (0.82 to 0.93 for the ball speed measurements.The results of this study indicate that dynamic and high volume upper extremity plyometric WU activities are likely beneficial to serve speed of elite junior tennis players.

  11. High frequency oscillatory ventilation with lung volume optimization in very low birth weight newborns – a nine-year experience

    Directory of Open Access Journals (Sweden)

    José Nona

    2009-09-01

    Full Text Available Objective: To evaluate the clinical outcome of very low birth weight newborns, submitted to high frequency oscillatory ventilation with a strategy of early lung volume optimization. Methods: Descriptive prospective study in a nine-year period, between 1999 January 1st to 2008 January 1st. All the very low birth weight newborns were born in Dr. Alfredo da Costa Maternity, Lisbon, Portugal, were admitted to the Neonatal Intensive Care Unit and submitted to high frequency oscillatory ventilation with early lung volume optimization; these newborns were followed-up since birth and their charts were analyzed periodically until hospital discharge. Rresults: From a total population of 730 very low birth weight inborns, 117 babies died (16% and 613 survived (84%. The median of birth weight was 975 g and the gestational age median was 28 weeks. For the survivors, the median ventilation and oxygenation times were 3 and 18 days, respectively. The incidence of chronic lung disease was 9.5%, with nine newborns discharged on oxygen therapy. The incidence of intraventricular hemorrhage III – IV (total population group was 11.5% and the incidence of retinopathy of prematurity grade 3 or higher was 8.0%. Cconclusions: High frequency oscillatory ventilation with early lung volume optimization strategy reduced the need of respiratory support, and improved pulmonary and global outcomes in very low birth weight infants with respiratory distress syndrome.

  12. Excluded volume effects caused by high concentration addition of acid generators in chemically amplified resists used for extreme ultraviolet lithography

    Science.gov (United States)

    Kozawa, Takahiro; Watanabe, Kyoko; Matsuoka, Kyoko; Yamamoto, Hiroki; Komuro, Yoshitaka; Kawana, Daisuke; Yamazaki, Akiyoshi

    2017-08-01

    The resolution of lithography used for the high-volume production of semiconductor devices has been improved to meet the market demands for highly integrated circuits. With the reduction in feature size, the molecular size becomes non-negligible in the resist material design. In this study, the excluded volume effects caused by adding high-concentration acid generators were investigated for triphenylsulfonium nonaflate. The resist film density was measured by X-ray diffractometry. The dependences of absorption coefficient and protected unit concentration on acid generator weight ratio were calculated from the measured film density. Using these values, the effects on the decomposition yield of acid generators, the protected unit fluctuation, and the line edge roughness (LER) were evaluated by simulation on the basis of sensitization and reaction mechanisms of chemically amplified extreme ultraviolet resists. The positive effects of the increase in acid generator weight ratio on LER were predominant below the acid generator weight ratio of 0.3, while the negative effects became equivalent to the positive effects above the acid generator weight ratio of 0.3 owing to the excluded volume effects.

  13. High spatiotemporal resolution measurement of regional lung air volumes from 2D phase contrast x-ray images.

    Science.gov (United States)

    Leong, Andrew F T; Fouras, Andreas; Islam, M Sirajul; Wallace, Megan J; Hooper, Stuart B; Kitchen, Marcus J

    2013-04-01

    Described herein is a new technique for measuring regional lung air volumes from two-dimensional propagation-based phase contrast x-ray (PBI) images at very high spatial and temporal resolution. Phase contrast dramatically increases lung visibility and the outlined volumetric reconstruction technique quantifies dynamic changes in respiratory function. These methods can be used for assessing pulmonary disease and injury and for optimizing mechanical ventilation techniques for preterm infants using animal models. The volumetric reconstruction combines the algorithms of temporal subtraction and single image phase retrieval (SIPR) to isolate the image of the lungs from the thoracic cage in order to measure regional lung air volumes. The SIPR algorithm was used to recover the change in projected thickness of the lungs on a pixel-by-pixel basis (pixel dimensions ≈ 16.2 μm). The technique has been validated using numerical simulation and compared results of measuring regional lung air volumes with and without the use of temporal subtraction for removing the thoracic cage. To test this approach, a series of PBI images of newborn rabbit pups mechanically ventilated at different frequencies was employed. Regional lung air volumes measured from PBI images of newborn rabbit pups showed on average an improvement of at least 20% in 16% of pixels within the lungs in comparison to that measured without the use of temporal subtraction. The majority of pixels that showed an improvement was found to be in regions occupied by bone. Applying the volumetric technique to sequences of PBI images of newborn rabbit pups, it is shown that lung aeration at birth can be highly heterogeneous. This paper presents an image segmentation technique based on temporal subtraction that has successfully been used to isolate the lungs from PBI chest images, allowing the change in lung air volume to be measured over regions as small as the pixel size. Using this technique, it is possible to measure

  14. A new model for volume recombination in plane-parallel chambers in pulsed fields of high dose-per-pulse.

    Science.gov (United States)

    Gotz, M; Karsch, L; Pawelke, J

    2017-11-01

    In order to describe the volume recombination in a pulsed radiation field of high dose-per-pulse this study presents a numerical solution of a 1D transport model of the liberated charges in a plane-parallel ionization chamber. In addition, measurements were performed on an Advanced Markus ionization chamber in a pulsed electron beam to obtain suitable data to test the calculation. The experiment used radiation pulses of 4 μs duration and variable dose-per-pulse values up to about 1 Gy, as well as pulses of variable duration up to 308 [Formula: see text] at constant dose-per-pulse values between 85 mGy and 400 mGy. Those experimental data were compared to the developed numerical model and existing descriptions of volume recombination. At low collection voltages the observed dose-per-pulse dependence of volume recombination can be approximated by the existing theory using effective parameters. However, at high collection voltages large discrepancies are observed. The developed numerical model shows much better agreement with the observations and is able to replicate the observed behavior over the entire range of dose-per-pulse values and collection voltages. Using the developed numerical model, the differences between observation and existing theory are shown to be the result of a large fraction of the charge being collected as free electrons and the resultant distortion of the electric field inside the chamber. Furthermore, the numerical solution is able to calculate recombination losses for arbitrary pulse durations in good agreement with the experimental data, an aspect not covered by current theory. Overall, the presented numerical solution of the charge transport model should provide a more flexible tool to describe volume recombination for high dose-per-pulse values as well as for arbitrary pulse durations and repetition rates.

  15. Action of the isolated canine diaphragm on the lower ribs at high lung volumes.

    Science.gov (United States)

    De Troyer, André; Wilson, Theodore A

    2014-10-15

    The normal diaphragm has an inspiratory action on the lower ribs, but subjects with chronic obstructive pulmonary disease commonly have an inward displacement of the lateral portions of the lower rib cage during inspiration. This paradoxical displacement, conventionally called 'Hoover's sign', has traditionally been attributed to the direct action of radially oriented diaphragmatic muscle fibres. In the present study, the inspiratory intercostal muscles in all interspaces in anaesthetized dogs were severed so that the diaphragm was the only muscle active during inspiration. The displacements of the lower ribs along the craniocaudal and laterolateral axes and the changes in pleural pressure (∆Ppl) and transdiaphragmatic pressure were measured during occluded breaths and mechanical ventilation at different lung volumes between functional residual capacity (FRC) and total lung capacity. From these data, the separate effects on rib displacement of ∆Ppl and of the force exerted by the diaphragm on the ribs were determined. Isolated spontaneous diaphragm contraction at FRC displaced the lower ribs cranially and outward, but this motion was progressively reversed into a caudal and inward motion as lung volume increased. However, although the force exerted by the diaphragm on the ribs decreased with increasing volume, it continued to displace the ribs cranially and outward. These observations suggest that Hoover's sign is usually caused by the decrease in the zone of apposition and, thus, by the dominant effect of ∆Ppl on the lower ribs, rather than an inward pull from the diaphragm. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.

  16. Influence of Utilization of High-Volumes of Class F Fly Ash on the Abrasion Resistance of Concrete

    Directory of Open Access Journals (Sweden)

    William PRINCE

    2007-01-01

    Full Text Available Utilization of large volumes of fly ash in various concrete applications is a becoming a more general practice in an efforts towards using large quantities of fly ash. Around the world, Class C or Class F or both as available have been used in high volumes in cement-based materials. In India, majority of fly generated is of Class F type as per ASTM C 618. Yearly fly ash generation in India is approximately 95 million tonnes. Out of which around 15-20% is utilized in cement production and cement/concrete related activities. In order to increase its percentage utilization, an investigation was carried out to use it in concrete.In this paper, abrasion resistance of high volume fly ash (HVFA concretes made with 35, 45, 55, and 65% of cement replacement was evaluated in terms of its relation with compressive strength. Comparison was made between ordinary Portland cement and fly ash concrete. Test results indicated that abrasion resistance of concrete having cement replacement up to 35 percent was comparable to the normal concrete mix with out fly ash. Beyond 35% cement replacement, fly ash concretes exhibited slightly lower resistance to abrasion relative to non-fly ash concretes. Test results further indicated that abrasion resistance of concrete is closely related with compressive strength, and had a very good correlation between abrasion resistance and compressive strength (R2 value between 0.9018 and 0.9859 depending upon age.

  17. Intenational conference on high-energy physics. Volume 2. Sessions IV to VIII. [Geneva, June 27-July 4, 1979

    Energy Technology Data Exchange (ETDEWEB)

    1980-02-01

    Volume 2 of the conference proceedings contains sessions on hadron physics, charged-lepton physics, the p-p-bar collider at CERN, future European accelerator possibilities, parallel discussion sessions (on high-energy) hadron-induced reactions, deep inelastic phenomena, hadron spectroscopy, weak ineractions and gauge theories, and quark confinement), and a closing session on gauge appreciation of developments in particle physics. A list of participants is also included. Three of the papers in this volume have already been cited in ERA, and can be found as reference to the entry CONF-790642-- in the Report Number Index. The remaining 36 will be processed as they are received on the Atomindex tape. (RWR)

  18. Study of emission of a volume nanosecond discharge plasma in xenon, krypton and argon at high pressures

    International Nuclear Information System (INIS)

    Baksht, E Kh; Lomaev, Mikhail I; Rybka, D V; Tarasenko, Viktor F

    2006-01-01

    The emission properties of a volume nanosecond discharge plasma produced in xenon, krypton and argon at high pressures in a discharge gap with a cathode having a small radius of curvature are studied. Spectra in the range 120-850 nm and amplitude-time characteristics of xenon emission at different regimes and excitation techniques are recorded and analysed. It is shown that upon excitation of the volume discharge initiated by a beam of avalanche electrons, at least 90% of the energy in the spectral range 120-850 nm is emitted by xenon dimers. For xenon at a pressure of 1.2 atm, ∼45 mJ of the spontaneous emission energy was obtained in the full solid angle in a pulse with the full width at half-maximum ∼130 ns. (laser applications and other topics in quantum electronics)

  19. Comparison of different volumes of high intensity interval training on cardiac autonomic function in sedentary young women.

    Science.gov (United States)

    Bhati, Pooja; Bansal, Vishal; Moiz, Jamal Ali

    2017-08-24

    Purpose The present study was conducted to compare the effects of low volume of high intensity interval training (LVHIIT) and high volume of high intensity interval training (HVHIIT) on heart rate variability (HRV) as a primary outcome measure, and on maximum oxygen consumption (VO2max), body composition, and lower limb muscle strength as secondary outcome measures, in sedentary young women. Methods Thirty-six participants were recruited in this study. The LVHIIT group (n = 17) performed one 4-min bout of treadmill running at 85%-95% maximum heart rate (HRmax), followed by 3 min of recovery by running at 70% HRmax, three times per week for 6 weeks. The HVHIIT group (n = 15) performed four times 4-min bouts of treadmill running at 85%-95% HRmax, interspersed with 3-min of recovery by running at 70% HRmax, 3 times per week for 6 weeks. All criterion measures were measured before and after training in both the groups. Results Due to attrition of four cases, data of 32 participants was used for analysis. A significant increase in high frequency (HF) power (p high frequency power (LF/HF) ratio (p body composition, and muscle strength. Conclusion The study results suggest that both LVHIIT and HVHIIT are equally effective in improving VO2max, body composition, and muscle strength, in sedentary young women. However, HVHIIT induces parasympathetic dominance as well, as measured by HRV.

  20. Prostate cancer volume associates with preoperative plasma levels of testosterone that independently predicts high grade tumours which show low densities (quotient testosterone/tumour volume

    Directory of Open Access Journals (Sweden)

    Antonio B. Porcaro

    2016-01-01

    Conclusion: The investigation shows that TT relates to volume and grade of PCa; moreover, the density of TT relative to TV inversely associates with rate of increase of cancer that depends on the grade of the tumour.

  1. Influence of high volumes of ultra-fine additions on self-compacting concrete[ACI SP-239

    Energy Technology Data Exchange (ETDEWEB)

    Cioffi, R. [Naples Univ., Naples (Italy). Faculty of Engineering; Colangelo, F. [Naples Univ., Naples (Italy). Dept. of Technologies; Caputo, D.; Liguori, B. [Naples Univ., Naples (Italy). Dept. of Materials and Production Engineering

    2006-07-01

    The addition of fine minerals can reduce water demand and increase the slump characteristics of concrete. This paper examined the influence of high volumes of ultra-fine fly ash, raw fly ash, silica fume and natural zeolites on the properties of self-compacting concrete (SCC). Three samples of SCC were prepared using various mineral additions to determine normal slump and J-ring slump flows of fresh concrete as well as the compressive strength and elastic modulus properties of hardened concrete. Cement and crushed limestone natural aggregates were used. The fly ash, silica fume and natural zeolites were subjected to wet high energy milling. The rotating speed, milling time, water-to-solid ratio, and size of milling media were optimized to obtain powders with varying qualities. Results of the study showed that values for the normal slump flow ranged between 604 and 785 mm, while the differences with the J-ring slump flow were less than 30 mm. The samples were then tested to evaluate the mechanical properties of the hardened concrete after 7 and 28 curing days. The modulus of elasticity and compressive strength showed improvements in the concretes containing the ultra-fine fly ash. No segregation phenomena were observed in the case of the cylindrical column specimens. It was concluded that all the specimens provided environmentally sustainable, high workability concretes which can be successfully prepared with the addition of high volumes of minerals. 17 refs., 5 tabs., 6 figs.

  2. Cesium-enhanced D sup - beam characteristics from a high-brightness volume source

    Energy Technology Data Exchange (ETDEWEB)

    Debiak, T.W. (Grumman Corporate Research Center, Bethpage, NY (USA))

    1991-05-01

    Previous experiments have demonstrated that the H{sup -} beam extracted from a volume ion source may increase by a factor of 4 or more when cesium vapor is introduced into the arc discharge chamber. We have extended these experiments to cesiated D{sup -} beams transported with and without space-charge neutralization by xenon gas. The D{sup -} results show qualitatively similar characteristics to those obtained with H{sup -}. In particular, a factor of almost 7 in current enhancement was obtained compared with noncesiated beams accompanied by a dramatic reduction in electron current. A study of the beam divergence as a function of extracted equivalent current showed that the divergence of the cesiated beams was larger than the uncesiated beams at the same equivalent current. Introduction of xenon gas at a partial pressure of 2.5x10{sup -5} Torr reduced the divergence of the cesiated beams to the value obtained for the uncesiated beams. (orig.).

  3. High integrity software for nuclear power plants: Candidate guidelines, technical basis and research needs. Executive summary: Volume 1

    International Nuclear Information System (INIS)

    Seth, S.; Bail, W.; Cleaves, D.; Cohen, H.; Hybertson, D.; Schaefer, C.; Stark, G.; Ta, A.; Ulery, B.

    1995-06-01

    The work documented in this report was performed in support of the US Nuclear Regulatory Commission to examine the technical basis for candidate guidelines that could be considered in reviewing and evaluating high integrity computer software used in the safety systems of nuclear power plants. The framework for the work consisted of the following software development and assurance activities: requirements specification; design; coding; verification and validation, including static analysis and dynamic testing; safety analysis; operation and maintenance; configuration management; quality assurance; and planning and management. Each activity (framework element) was subdivided into technical areas (framework subelements). The report describes the development of approximately 200 candidate guidelines that span the entire range of software life-cycle activities; the assessment of the technical basis for those candidate guidelines; and the identification, categorization and prioritization of research needs for improving the technical basis. The report has two volumes: Volume 1, Executive Summary, includes an overview of the framework and of each framework element, the complete set of candidate guidelines, the results of the assessment of the technical basis for each candidate guideline, and a discussion of research needs that support the regulatory function; Volume 2 is the main report

  4. High integrity software for nuclear power plants: Candidate guidelines, technical basis and research needs. Main report, Volume 2

    International Nuclear Information System (INIS)

    Seth, S.; Bail, W.; Cleaves, D.; Cohen, H.; Hybertson, D.; Schaefer, C.; Stark, G.; Ta, A.; Ulery, B.

    1995-06-01

    The work documented in this report was performed in support of the US Nuclear Regulatory Commission to examine the technical basis for candidate guidelines that could be considered in reviewing and evaluating high integrity computer e following software development and assurance activities: Requirements specification; design; coding; verification and validation, inclukding static analysis and dynamic testing; safety analysis; operation and maintenance; configuration management; quality assurance; and planning and management. Each activity (framework element) was subdivided into technical areas (framework subelements). The report describes the development of approximately 200 candidate guidelines that span the entire ran e identification, categorization and prioritization of technical basis for those candidate guidelines; and the identification, categorization and prioritization of research needs for improving the technical basis. The report has two volumes: Volume 1, Executive Summary includes an overview of the framwork and of each framework element, the complete set of candidate guidelines, the results of the assessment of the technical basis for each candidate guideline, and a discussion of research needs that support the regulatory function; this document, Volume 2, is the main report

  5. High integrity software for nuclear power plants: Candidate guidelines, technical basis and research needs. Main report, Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Seth, S.; Bail, W.; Cleaves, D.; Cohen, H.; Hybertson, D.; Schaefer, C.; Stark, G.; Ta, A.; Ulery, B. [Mitre Corp., McLean, VA (United States)

    1995-06-01

    The work documented in this report was performed in support of the US Nuclear Regulatory Commission to examine the technical basis for candidate guidelines that could be considered in reviewing and evaluating high integrity computer e following software development and assurance activities: Requirements specification; design; coding; verification and validation, inclukding static analysis and dynamic testing; safety analysis; operation and maintenance; configuration management; quality assurance; and planning and management. Each activity (framework element) was subdivided into technical areas (framework subelements). The report describes the development of approximately 200 candidate guidelines that span the entire ran e identification, categorization and prioritization of technical basis for those candidate guidelines; and the identification, categorization and prioritization of research needs for improving the technical basis. The report has two volumes: Volume 1, Executive Summary includes an overview of the framwork and of each framework element, the complete set of candidate guidelines, the results of the assessment of the technical basis for each candidate guideline, and a discussion of research needs that support the regulatory function; this document, Volume 2, is the main report.

  6. USAF Summer Research Program - 1995 High School Apprenticeship Program Final Reports, Volume 14, Rome Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1995-01-01

    The United States Air Force High School Apprenticeship Program's (USAF HSAP) purpose is to place outstanding high school students whose interests are in the areas of mathematics, engineering, and science to work in a laboratory environment...

  7. High-intensity high-volume swimming induces more robust signaling through PGC-1α and AMPK activation than sprint interval swimming in m. triceps brachii

    DEFF Research Database (Denmark)

    Casuso, Rafael A; Plaza-Díaz, Julio; Ruiz-Ojeda, Francisco J

    2017-01-01

    We aimed to test whether high-intensity high-volume training (HIHVT) swimming would induce more robust signaling than sprint interval training (SIT) swimming within the m. triceps brachii due to lower metabolic and oxidation. Nine well-trained swimmers performed the two training procedures...... on separate randomized days. Muscle biopsies from m. triceps brachii and blood samples were collected at three different time points: a) before the intervention (pre), b) immediately after the swimming procedures (post) and c) after 3 h of rest (3 h). Hydroperoxides, creatine kinase (CK), and lactate...

  8. High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 7. Revision 1

    International Nuclear Information System (INIS)

    Burt, D.L.

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Identification Document (S/RID) is contained in multiple volumes. This document (Volume 7) presents the standards and requirements for the following sections: Occupational Safety and Health, and Environmental Protection

  9. High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 7. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Burt, D.L.

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Identification Document (S/RID) is contained in multiple volumes. This document (Volume 7) presents the standards and requirements for the following sections: Occupational Safety and Health, and Environmental Protection.

  10. Topology of genetic associations between regional gray matter volume and intellectual ability: Evidence for a high capacity network.

    Science.gov (United States)

    Bohlken, Marc M; Brouwer, Rachel M; Mandl, René C W; Hedman, Anna M; van den Heuvel, Martijn P; van Haren, Neeltje E M; Kahn, René S; Hulshoff Pol, Hilleke E

    2016-01-01

    Intelligence is associated with a network of distributed gray matter areas including the frontal and parietal higher association cortices and primary processing areas of the temporal and occipital lobes. Efficient information transfer between gray matter regions implicated in intelligence is thought to be critical for this trait to emerge. Genetic factors implicated in intelligence and gray matter may promote a high capacity for information transfer. Whether these genetic factors act globally or on local gray matter areas separately is not known. Brain maps of phenotypic and genetic associations between gray matter volume and intelligence were made using structural equation modeling of 3T MRI T1-weighted scans acquired in 167 adult twins of the newly acquired U-TWIN cohort. Subsequently, structural connectivity analyses (DTI) were performed to test the hypothesis that gray matter regions associated with intellectual ability form a densely connected core. Gray matter regions associated with intellectual ability were situated in the right prefrontal, bilateral temporal, bilateral parietal, right occipital and subcortical regions. Regions implicated in intelligence had high structural connectivity density compared to 10,000 reference networks (p=0.031). The genetic association with intelligence was for 39% explained by a genetic source unique to these regions (independent of total brain volume), this source specifically implicated the right supramarginal gyrus. Using a twin design, we show that intelligence is genetically represented in a spatially distributed and densely connected network of gray matter regions providing a high capacity infrastructure. Although genes for intelligence have overlap with those for total brain volume, we present evidence that there are genes for intelligence that act specifically on the subset of brain areas that form an efficient brain network. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Evaluation of sampling inhalable PM10 particulate matter (≤ 10 μm) using co-located high volume samplers

    International Nuclear Information System (INIS)

    Rajoy, R R S; Dias, J W C; Rego, E C P; Netto, A D Pereira

    2015-01-01

    This paper presents the results of the determination of the concentrations of atmospheric particulate matter ≤ 10 μm (PM10), collected simultaneously by six PM10 high volume samplers from two different manufacturers installed in the same location. Fifteen samples of 24 h were obtained with each equipment at a selected urban area of Rio de Janeiro city. The concentration of PM10 ranged between 10.73 and 54.04 μg m −3 . The samplers were considered comparable to each other, as the adopted methodology presented good repeatability

  12. Association Between Treatment at a High-Volume Facility and Improved Survival for Radiation-Treated Men With High-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yu-Wei [Department of Radiation Oncology, Dana-Farber Cancer Institute and Brigham and Women' s Hospital, Boston, Massachusetts (United States); Mahal, Brandon A. [Department of Medicine, Brigham and Women' s Hospital, Boston, Massachusetts (United States); Harvard Medical School, Boston, Massachusetts (United States); Muralidhar, Vinayak [Department of Radiation Oncology, Dana-Farber Cancer Institute and Brigham and Women' s Hospital, Boston, Massachusetts (United States); Harvard Medical School, Boston, Massachusetts (United States); Nezolosky, Michelle [Department of Radiation Oncology, Dana-Farber Cancer Institute and Brigham and Women' s Hospital, Boston, Massachusetts (United States); Beard, Clair J. [Department of Radiation Oncology, Dana-Farber Cancer Institute and Brigham and Women' s Hospital, Boston, Massachusetts (United States); Harvard Medical School, Boston, Massachusetts (United States); Den, Robert B. [Department of Radiation Oncology, Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, Pennsylvania (United States); Feng, Felix Y. [Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, Michigan (United States); Hoffman, Karen E. [Department of Radiation Oncology, the University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Martin, Neil E.; Orio, Peter F. [Department of Radiation Oncology, Dana-Farber Cancer Institute and Brigham and Women' s Hospital, Boston, Massachusetts (United States); Harvard Medical School, Boston, Massachusetts (United States); Nguyen, Paul L., E-mail: pnguyen@LROC.harvard.edu [Department of Radiation Oncology, Dana-Farber Cancer Institute and Brigham and Women' s Hospital, Boston, Massachusetts (United States); Harvard Medical School, Boston, Massachusetts (United States)

    2016-03-15

    Purpose: Although the association between higher hospital volume and improved outcomes has been well-documented in surgery, there is little data about whether this effect exists for radiation-treated patients. We investigated whether treatment at a radiation facility that treats a high volume of prostate cancer patients is associated with improved survival for men with high-risk prostate cancer. Methods and Materials: We used the National Cancer Database (NCDB) to identity patients diagnosed with prostate cancer from 2004 to 2006. The radiation case volume (RCV) of each hospital was based on its number of radiation-treated prostate cancer patients. We used propensity-score based analysis to compare the overall survival (OS) of high-risk prostate cancer patients in high versus low RCV hospitals. Primary endpoint is overall survival. Covariates adjusted for were tumor characteristics, sociodemographic factors, radiation type, and use of androgen deprivation therapy (ADT). Results: A total of 19,565 radiation-treated high-risk patients were identified. Median follow-up was 81.0 months (range: 1-108 months). When RCV was coded as a continuous variable, each increment of 100 radiation-managed patients was associated with improved OS (adjusted hazard ratio [AHR]: 0.97; 95% confidence interval [CI]: 0.95-0.98; P<.0001) after adjusting for known confounders. For illustrative purposes, when RCV was dichotomized at the 80th percentile (43 patients/year), high RCV was associated with improved OS (7-year overall survival 76% vs 74%, log-rank test P=.0005; AHR: 0.91, 95% CI: 0.86-0.96, P=.0005). This association remained significant when RCV was dichotomized at 75th (37 patients/year), 90th (60 patients/year), and 95th (84 patients/year) percentiles but not the 50th (19 patients/year). Conclusions: Our results suggest that treatment at centers with higher prostate cancer radiation case volume is associated with improved OS for radiation-treated men with high-risk prostate

  13. A molecular dynamics study of ambient and high pressure phases of silica: structure and enthalpy variation with molar volume.

    Science.gov (United States)

    Rajappa, Chitra; Sringeri, S Bhuvaneshwari; Subramanian, Yashonath; Gopalakrishnan, J

    2014-06-28

    Extensive molecular dynamics studies of 13 different silica polymorphs are reported in the isothermal-isobaric ensemble with the Parrinello-Rahman variable shape simulation cell. The van Beest-Kramer-van Santen (BKS) potential is shown to predict lattice parameters for most phases within 2%-3% accuracy, as well as the relative stabilities of different polymorphs in agreement with experiment. Enthalpies of high-density polymorphs - CaCl2-type, α-PbO2-type, and pyrite-type - for which no experimental data are available as yet, are predicted here. Further, the calculated enthalpies exhibit two distinct regimes as a function of molar volume-for low and medium-density polymorphs, it is almost independent of volume, while for high-pressure phases a steep dependence is seen. A detailed analysis indicates that the increased short-range contributions to enthalpy in the high-density phases arise not only from an increased coordination number of silicon but also shorter Si-O bond lengths. Our results indicate that amorphous phases of silica exhibit better optimization of short-range interactions than crystalline phases at the same density while the magnitude of Coulombic contributions is lower in the amorphous phase.

  14. Short-term moderate intensive high volume training program provides aerobic endurance benefit in wheelchair basketball players.

    Science.gov (United States)

    Skucas, Kestutis; Pokvytyte, Vaida

    2017-04-01

    The aim of this paper was to investigate the effect of short-term period, moderate intensity and high volume endurance training on physiological variables in elite wheelchair basketball players. Eight wheelchair basketball players were examined. The subjects participated in a two-week intervention program of mainly two training types: wheelchair basketball and wheelchair driving endurance training. The subjects performed the continuously increasing cycling exercise (CCE) at the constant 60 rpm arm cranking speed at the beginning of the program and after two weeks of the program. The initial workload was 20 W, then the workload was increased by 2 W every 5 seconds until fatigue. The post training of the wheelchair basketball group in the study showed a significant improvement in the peak oxygen uptake (VO2peak) and the peak power output (POpeak). VO2peak increased by 9% from 2.32±0.16 L/min to 2.53±0.2 L/min (Pbasketball squad had relatively high levels of aerobic fitness prior to participating in the endurance training program. Nevertheless, the high-volume, moderate-intensity, short-term training program, which evolved over the two-weeks period, resulted in the improvement of the athlete's aerobic endurance. The ventilatory threshold (VT) and the second ventilatory threshold (VT2) are good markers for aerobic capacity of wheelchair athletes.

  15. Identifying practice-related factors for high-volume prescribers of antibiotics in Danish general practice

    DEFF Research Database (Denmark)

    Aabenhus, Rune; Siersma, Volkert Dirk; Sandholdt, Håkon

    2017-01-01

    practice-related factors driving high antibiotic prescribing rates. Results: We included 98% of general practices in Denmark (n = 1962) and identified a 10% group of high prescribers who accounted for 15% of total antibiotic prescriptions and 18% of critically important antibiotic prescriptions. Once case...... prescriptions issued over the phone compared with all antibiotic prescriptions; and a high number of consultations per 1000 patients. We also found that a low number of consultations per 1000 patients was associated with a reduced likelihood of being a high prescriber of antibiotics. Conclusions: An apparent...

  16. Mechanical Properties of High Volume Fly Ash Concrete Reinforced with Hybrid Fibers

    Directory of Open Access Journals (Sweden)

    Rooban Chakravarthy

    2016-01-01

    Full Text Available Fly ash substitution to cement is a well-recognized approach to reduce CO2 emissions. Although fly ash concrete is prone to brittle behavior, researchers have shown that addition of fibers could reduce brittle behavior. Previous research efforts seem to have utlised a single type of fiber or two types of fibers. In this research, three types of fibers, steel, polypropylene, and basalt as 0%, 0.50%, 0.75%, and 1% by volume of concrete, were mixed in varying proportions with concrete specimens substituted with 50% fly ash (class F. All specimens were tested for compressive strength, indirect tensile strength, and flexural strength over a period of 3 to 56 days of curing. Test results showed that significant improvement in mechanical properties could be obtained by a particular hybrid fiber reinforcement combination (1% steel fiber, 0.75% polypropylene fiber, and 0.75% basalt fiber. The strength values were observed to exceed previous research results. Workability of concrete was affected when the fiber combination exceeded 3%. Thus a limiting value for adding fibers and the combination to achieve maximum strengths have been identified in this research.

  17. Studies in Mathematics, Volume X. Applied Mathematics in the High School.

    Science.gov (United States)

    Schiffer, Max M.

    This publication contains a sequence of lectures given to high school mathematics teachers by the author. Applications of mathematics emphasized are elementary algebra, geometry, and matrix algebra. Included are: (1) an introduction concerning teaching applications of mathematics; (2) Chapter 1: Mechanics for the High School Student; (3) Chapter…

  18. SyPRID sampler: A large-volume, high-resolution, autonomous, deep-ocean precision plankton sampling system

    Science.gov (United States)

    Billings, Andrew; Kaiser, Carl; Young, Craig M.; Hiebert, Laurel S.; Cole, Eli; Wagner, Jamie K. S.; Van Dover, Cindy Lee

    2017-03-01

    The current standard for large-volume (thousands of cubic meters) zooplankton sampling in the deep sea is the MOCNESS, a system of multiple opening-closing nets, typically lowered to within 50 m of the seabed and towed obliquely to the surface to obtain low-spatial-resolution samples that integrate across 10 s of meters of water depth. The SyPRID (Sentry Precision Robotic Impeller Driven) sampler is an innovative, deep-rated (6000 m) plankton sampler that partners with the Sentry Autonomous Underwater Vehicle (AUV) to obtain paired, large-volume plankton samples at specified depths and survey lines to within 1.5 m of the seabed and with simultaneous collection of sensor data. SyPRID uses a perforated Ultra-High-Molecular-Weight (UHMW) plastic tube to support a fine mesh net within an outer carbon composite tube (tube-within-a-tube design), with an axial flow pump located aft of the capture filter. The pump facilitates flow through the system and reduces or possibly eliminates the bow wave at the mouth opening. The cod end, a hollow truncated cone, is also made of UHMW plastic and includes a collection volume designed to provide an area where zooplankton can collect, out of the high flow region. SyPRID attaches as a saddle-pack to the Sentry vehicle. Sentry itself is configured with a flight control system that enables autonomous survey paths to low altitudes. In its verification deployment at the Blake Ridge Seep (2160 m) on the US Atlantic Margin, SyPRID was operated for 6 h at an altitude of 5 m. It recovered plankton samples, including delicate living larvae, from the near-bottom stratum that is seldom sampled by a typical MOCNESS tow. The prototype SyPRID and its next generations will enable studies of plankton or other particulate distributions associated with localized physico-chemical strata in the water column or above patchy habitats on the seafloor.

  19. High Volume Manufacturing of NanoEngineered High ZT Thermoelectrics for Multiple Energy Generation Applications, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — SMI has teamed with a leading thermoelectric (TE) research group in order to optimize and convert high-performance TE materials developed in laboratory-scale into...

  20. High lung cancer surgical procedure volume is associated with shorter length of stay and lower risks of re-admission and death

    DEFF Research Database (Denmark)

    Møller, Henrik; Riaz, Sharma P; Holmberg, Lars

    2016-01-01

    It is debated whether treating cancer patients in high-volume surgical centres can lead to improvement in outcomes, such as shorter length of hospital stay, decreased frequency and severity of post-operative complications, decreased re-admission, and decreased mortality. The dataset for this anal......It is debated whether treating cancer patients in high-volume surgical centres can lead to improvement in outcomes, such as shorter length of hospital stay, decreased frequency and severity of post-operative complications, decreased re-admission, and decreased mortality. The dataset...... to their geographical population. Higher volume hospitals had shorter length of stay and the odds of re-admission were 15% lower in the highest hospital volume quintile compared with the lowest quintile. Mortality risks were 1% after 30 d and 3% after 90 d. Patients from hospitals in the highest volume quintile had...

  1. Low Cost High Performance Generator Technology Program. Volume 4. Mission application study

    International Nuclear Information System (INIS)

    1975-07-01

    Results of initial efforts to investigate application of selenide thermoelectric RTG's to specific missions as well as an indication of development requirements to enable satisfaction of emerging RTG performance criteria are presented. Potential mission applications in DoD such as SURVSATCOM, Advance Defense Support Program, Laser Communication Satellite, Satellite Data System, Global Positioning Satellite, Deep Space Surveillance Satellite, and Unmanned Free Swimming Submersible illustrate power requirements in the range of 500 to 1000 W. In contrast, the NASA applications require lower power ranging from 50 W for outer planetary atmospheric probes to about 200 W for spacecraft flights to Jupiter and other outer planets. The launch dates for most of these prospective missions is circa 1980, a requirement roughly compatible with selenide thermoelectric and heat source technology development. A discussion of safety criteria is included to give emphasis to the requirements for heat source design. In addition, the observation is made that the potential accident environments of all launch vehicles are similar so that a reasonable composite set of design specifications may be derived to satisfy almost all applications. Details of the LCHPG application potential is afforded by three designs: an 80 W RTG using improved selenide thermoelectric material, a 55 to 65 W LCHPG using current and improved selenide materials, and the final 500 W LCHPG as reported in Volume 2. The final results of the LCHPG design study have shown that in general, all missions can expect an LCHPG design which yields 10 percent efficiency at 3 W/lb with the current standard selenide thermoelectric materials, with growth potential to 14 percent at greater than 4 W/lb in the mid 1980's time frame

  2. Investigation of high-current low pressure quasistationary volume discharge in cross-field ExH

    International Nuclear Information System (INIS)

    Bashutin, O.A.; Vovchenko, E.D.; Kirnev, G.S.

    1995-01-01

    Different types of high current discharge permitted to create large volume of high density homogeneous plasma are widely used in modern technique. Such discharges are applied as plasma emitters of charged particles and also in various technologies for sputtering, implantation and etching of materials. The results of a plasma electron density dynamics investigation of low pressure quasistationary volume discharge in cross-field E x H is described in this paper. The discharge was created in a quadrupole magnetic system with special form electrodes and has following characteristics current up to 1,8 kA, voltage on the interval 80-120 V, existence time up to 1,5 ms. The discharge conserves diffusive character of plasma and cathode layer on all current range. On a first research stage plasma parameters of discharge were determined by means of Langmuir probe, that could been used in central discharge region only, where magnetic field was equal to zero. An obtained plasma density was reached 1,5*10 15 cm -3 with electron temperature T e =10 eV. The research of discharge plasma in regions with magnetic field had required to use interferometric measurement technique

  3. Design and evaluation of high-volume fly ash (HVFA) concrete mixes, report D : creep, shrinkage, and abrasion resistance of HVFA concrete.

    Science.gov (United States)

    2012-10-01

    The main objective of this study was to determine the effect on shrinkage, creep, : and abrasion resistance of high-volume fly ash (HVFA) concrete. The HVFA concrete : test program consisted of comparing the shrinkage, creep, and abrasion performance...

  4. Modeling emissions and environmental impacts of transportation activities associated with high volume horizontal hydraulic fracturing operations in the Marcellus Shale Formation : final report.

    Science.gov (United States)

    2015-09-18

    The researchers' initial University Transportation Research Center (UTRC) research project identified routes and road segments with predicted high volumes of truck traffic related to natural gas extraction in the Marcellus Shale region. Results also ...

  5. Advances on Propulsion Technology for High-Speed Aircraft. Volume 1

    National Research Council Canada - National Science Library

    2007-01-01

    .... The demand for supersonic vehicles is believed to boost in the incoming years. This VKI/RTO lecture series will review the current state of the art of high speed propulsion for both airplanes and space launchers...

  6. Advances on Propulsion Technology for High-Speed Aircraft. Volume 2

    National Research Council Canada - National Science Library

    2007-01-01

    .... The demand for supersonic vehicles is believed to boost in the incoming years. This VKI/RTO lecture series will review the current state of the art of high speed propulsion for both airplanes and space launchers...

  7. DOE public hearing held at the Calais High School, Calais, Maine, April 8, 1986: Volume 1

    International Nuclear Information System (INIS)

    1986-01-01

    This document contains a transcript of the comments of 20 witnesses. These meetings were held to hear public comments regarding the selection of a site for a second high-level nuclear waste repository

  8. Summer Research Program - 1996 High School Apprenticeship Program Volume 15A Wright Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1996-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  9. Summer Research Program - 1996 High School Apprenticeship Program. Volume 12B, Armstrong Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1996-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  10. Summer Research Program - 1998 High School Apprenticeship Program Final Reports. Volume 12, Armstrong Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1998-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  11. Summer Research Program - 1996 High School Apprenticeship Program. Volume 16, Arnold Engineering Development Center

    National Research Council Canada - National Science Library

    Moore, Gary

    1996-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  12. Summer Research Program - 1997. High School Apprenticeship Program. Final Reports, Volume 12A, Armstrong Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1997-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  13. Summer Research Program - 1998 High School Apprenticeship Program. Volume 14. Phillips Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1998-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  14. Summer Research Program - 1997. High School Apprenticeship Program. Final Reports Volume 15B, Wright Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1997-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  15. Summer Research Program - 1996. High School Apprenticeship Program Final Reports. Volume 15B, Wright Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1996-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  16. Summer Research Program - 1998 High School Apprenticeship Program Volume 15C Wright Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1998-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  17. Summer Research Program - 1998 High School Apprenticeship Program Volume 13 Rome Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1998-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  18. 1997 Summer Research Program (SRP), High School Apprenticeship Program (HSAP), Final Reports, Volume 13, Phillips Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1997-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  19. Summer Research Program - 1997 High School Apprenticeship Program. Volume 14, Rome Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1997-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  20. Summer Research Program - 1997. High School Apprenticeship Program Final Reports. Volume 15A, Wright Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1997-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  1. Summer Research Program - 1998 High School Apprenticeship Program Volume 15B Wright Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1998-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  2. Summer Research Program - 1997 High School Appenticeship Program Volume 16 Arnold Engineering Development Center

    National Research Council Canada - National Science Library

    Moore, Gary

    1997-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  3. Summer Research Program - 1997. High School Apprenticeship Program. Final Reports. Volume 15C, Wright Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1997-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  4. Summer Research Program - 1996 High School Apprenticeship Program Volume 13 Phillips Laboratory

    National Research Council Canada - National Science Library

    Moore, Gary

    1996-01-01

    The United States Air Force Summer Research Program (USAF-SRP) is designed to introduce university, college, and technical institute faculty members, graduate students, and high school students to Air Force research...

  5. Manufacturing Technology for High Voltage Power Supplies (HVPS). Volume III - Procedural Details

    National Research Council Canada - National Science Library

    1996-01-01

    .... The thrust of this program was to improve the reliability of High Voltage Power Supplies (HVPS). This was accomplished conducting a comprehensive evaluation of the materials, components and processes used to produce HVPS...

  6. High-Level Waste Salt Disposition Systems Engineering Team Final Report, Volumes I, II, and III

    International Nuclear Information System (INIS)

    Piccolo, S.F.

    1999-01-01

    This report describes the process used and results obtained by the High Level Waste Salt Disposition Systems Engineering Team to select a primary and backup alternative salt disposition method for the Savannah River Site

  7. The Effects of Design Strength, Fly Ash Content and Curing Method on Compressive Strength of High Volume Fly Ash Concrete: A Design of Experimental

    OpenAIRE

    Solikin Mochamad; Setiawan Budi

    2017-01-01

    High volume fly ash concrete becomes one of alternatives to produce green concrete as it uses waste material and significantly reduces the utilization of Portland cement in concrete production. Although using less cement, its compressive strength is comparable to ordinary Portland cement (hereafter OPC) and the its durability increases significantly. This paper reports investigation on the effect of design strength, fly ash content and curing method on compressive strength of High Volume Fly ...

  8. Transient analysis of electromagnetic wave interactions on high-contrast scatterers using volume electric field integral equation

    KAUST Repository

    Sayed, Sadeed Bin

    2014-07-01

    A marching on-in-time (MOT)-based time domain volume electric field integral equation (TD-VEFIE) solver is proposed for accurate and stable analysis of electromagnetic wave interactions on high-contrast scatterers. The stability is achieved using band-limited but two-sided (non-causal) temporal interpolation functions and an extrapolation scheme to cast the time marching into a causal form. The extrapolation scheme is designed to be highly accurate for oscillating and exponentially decaying fields, hence it accurately captures the physical behavior of the resonant modes that are excited inside the dielectric scatterer. Numerical results demonstrate that the resulting MOT scheme maintains its stability as the number of resonant modes increases with the contrast of the scatterer.

  9. Feasibility of disposal of high-level radioactive waste into the seabed. Volume 3: Geoscience characterization studies

    International Nuclear Information System (INIS)

    Shephard, L.E.; Auffret, G.A.; Buckley, D.E.; Schuettenhelm, R.T.E.; Searle, R.C.

    1988-01-01

    One of the options suggested for disposal of high-level radioactive waste resulting from the generation of nuclear power is burial beneath the deep ocean floor in geologically stable sediment formations which have no economic value. The 8-volume series provides an assessment of the technical feasibility and radiological safety of this disposal concept based on the results obtained by ten years of co-operation and information exchange among the Member countries participating in the NEA Seabed Working Group. This report summarizes the results of a study performed to establish if, on the basis of available data, sites may be found that will satisfy the geoscience requirements for a potential subseabed high-level waste repository

  10. 2D and 3D milled surface roughness of high volume fraction SiCp/Al composites

    Directory of Open Access Journals (Sweden)

    Tao Wang

    2015-06-01

    Full Text Available This paper presents a study on surface roughness generated by high speed milling of high volume fraction (65% silicon carbide particle-reinforced aluminum matrix (SiCp/Al composites. Typical 2D (Ra and Rz and 3D (Sa and Sq surface roughness parameters were selected to evaluate the influence of the milling parameters on the surface quality in comparison with aluminum alloy. The 3D topography of the milled surface was studied as well. The results indicate that 3D parameters (Sa and Sq are more capable to describe the influence of the milling parameters on the surface quality, and among them Sq is preferable due to its good sensitivity. Sq decreases with milling speed and increases with feed rate. The influence of axial depth of cut (ADOC is negligible.

  11. Dedicated Perioperative Hip Fracture Comanagement Programs are Cost-effective in High-volume Centers: An Economic Analysis.

    Science.gov (United States)

    Swart, Eric; Vasudeva, Eshan; Makhni, Eric C; Macaulay, William; Bozic, Kevin J

    2016-01-01

    a full-time basis. Additionally, we evaluated the scenario where the necessary staff was already employed at the hospital and could be dedicated to a comanagement service on a part-time basis, and explored the effect of triaging only patients considered high risk to a comanagement service versus comanaging all geriatric patients. Finally, probabilistic sensitivity analysis was conducted on all critical variables, with broad ranges used for values around which there was higher uncertainty. For the base case, universal comanagement was more cost effective than traditional care and risk-stratified comanagement (incremental cost effectiveness ratios of USD 41,100 per quality-adjusted life-year and USD 81,900 per quality-adjusted life-year, respectively). Comanagement was more cost effective than traditional management as long as the case volume was more than 54 patients annually (range, 41-68 patients based on sensitivity analysis) and resulted in cost savings when there were more than 318 patients annually (range, 238-397 patients). In a scenario where staff could be partially dedicated to a comanagement service, universal comanagement was more cost effective than risk-stratified comanagement (incremental cost effectiveness of USD 2300 per quality-adjusted life-year), and both comanagement programs had lower costs and better outcomes compared with traditional management. Sensitivity analysis was conducted and showed that the level of uncertainty in key variables was not high enough to change the core conclusions of the model. Implementation of a systems-based comanagement strategy using a dedicated team to improve perioperative medical care and expedite preoperative evaluation is cost effective in hospitals with moderate volume and can result in cost savings at higher-volume centers. The optimum patient population for a comanagement strategy is still being defined. Level 1, Economic and Decision Analysis.

  12. Price duration versus trading volume in high-frequency data for selected DAX companies

    Directory of Open Access Journals (Sweden)

    Christoph Mitterer

    2016-12-01

    Full Text Available The properties of the time series of durations between consecutive trades of a particular stock have been studied by many contributors in the literature of financial econometrics. Among them are highly prominent scientists like Engle (2000 and Gourieroux and Jasiak (2001. The importance of this topic, accompanied by the growing availability of (ultra-high-frequency data, has prompted an increase of contributions in recent years. Intensive research based on high-frequency data has several financial motivations. First of all, it is linked with microstructure theory. Secondly, it contributes to the literature on stochastic time deformation. But the most important need for research on the dynamics of trade durations is the necessity to manage liquidity risk. The reason is that durations between the following trades are a widely accepted measures of market liquidity. In addition, their volatility reflects the liquidity risk.

  13. High-resolution neutron protein crystallography with radically small crystal volumes: Application of perdeuteration to human aldose reductase

    International Nuclear Information System (INIS)

    Hazemann, I.; Dauvergne, M.T.; Blakeley, M.P.; Meilleur, Flora; Haertlein, M.; Van Dorsselaer, A.; Mitschler, A.; Myles, Dean A.A.; Podjarny, A.

    2005-01-01

    Neutron diffraction data have been collected to 2.2 (angstrom) resolution from a small (0.15 mm 3 ) crystal of perdeuterated human aldose reductase (h-AR; MW = 36 kDa) in order to help to determine the protonation state of the enzyme. h-AR belongs to the aldo-keto reductase family and is implicated in diabetic complications. Its ternary complexes (h-AR-coenzyme NADPH-selected inhibitor) provide a good model to study both the enzymatic mechanism and inhibition. Here, the successful production of fully deuterated human aldose reductase (h-AR(D)), subsequent crystallization of the ternary complex h-AR(D)-NADPH-IDD594 and neutron Laue data collection at the LADI instrument at ILL using a crystal volume of just 0.15 mm 3 are reported. Neutron data were recorded to 2 (angstrom) resolution, with subsequent data analysis using data to 2.2 (angstrom). This is the first fully deuterated enzyme of this size (36 kDa) to be solved by neutron diffraction and represents a milestone in the field, as the crystal volume is at least one order of magnitude smaller than those usually required for other high-resolution neutron structures determined to date. This illustrates the significant increase in the signal-to-noise ratio of data collected from perdeuterated crystals and demonstrates that good-quality neutron data can now be collected from more typical protein crystal volumes. Indeed, the signal-to-noise ratio is then dominated by other sources of instrument background, the nature of which is under investigation. This is important for the design of future instruments, which should take maximum advantage of the reduction in the intrinsic diffraction pattern background from fully deuterated samples.

  14. Between demarcation and discretion: The medical-administrative boundary as a locus of safety in high-volume organisational routines.

    Science.gov (United States)

    Grant, Suzanne; Guthrie, Bruce

    2018-04-01

    Patient safety is an increasing concern for health systems internationally. The majority of administrative work in UK general practice takes place in the context of organisational routines such as repeat prescribing and test results handling, where high workloads and increased clinician dependency on administrative staff have been identified as an emerging safety issue. Despite this trend, most research to date has focused on the redistribution of the clinical workload between doctors, nurses and allied health professionals within individual care settings. Drawing on Strauss's negotiated order perspective, we examine ethnographically the achievement of safety across the medical-administrative boundary in key high-volume routines in UK general practice. We focus on two main issues. First, GPs engaged in strategies of demarcation by defining receptionist work as routine, unspecialised and dependent upon GP clinical knowledge and oversight as the safety net to deal with complexity and risk. Receptionists consented to this 'social closure' when describing their role, thus reinforcing the underlying inter-occupational relationship of medical domination. Second, in everyday practice, GPs and receptionists engaged in informal boundary-blurring to safely accommodate the complexity of everyday high-volume routine work. This comprised additional informal discretionary spaces for receptionist decision-making and action that went beyond the routine safety work formally assigned to them. New restratified intra-occupational hierarchies were also being created between receptionists based on the complexity of the safety work that they were authorised to do at practice level, with specialised roles constituting a new form of administrative 'professional project'. The article advances negotiated order theory by providing an in-depth examination of the ways in which medical-administrative boundary-making and boundary-blurring constitute distinct modes of safety in high-volume

  15. Intermediate photovoltaic system application experiment operational performance report. Volume 9 for Beverly High School, Beverly, Massachusetts

    Energy Technology Data Exchange (ETDEWEB)

    1982-07-01

    Presented are the data accumulated during May 1982 at the intermediate photovoltaic project at Beverly High School, Beverly, Massachusetts. Generated energy and environmental (weather) data are presented graphically. Explanations of irregularities not attributable to weather are provided. Due to computer damage data were acquired for only the first 7 days of the month, although the PV system continued normal operation.

  16. Renewable Electricity Futures Study. Volume 1. Exploration of High-Penetration Renewable Electricity Futures

    Energy Technology Data Exchange (ETDEWEB)

    Hand, M. M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Baldwin, S. [U.S. Dept. of Energy, Washington, DC (United States); DeMeo, E. [Renewable Energy Consulting, Chicago, IL (United States); Reilly, J. M. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Mai, T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Arent, D. [Joint Inst. for Strategic Energy Analysis, Boulder, CO (United States); Porro, G. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Meshek, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sandor, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-06-15

    The Renewable Electricity Futures (RE Futures) Study investigated the challenges and impacts of achieving very high renewable electricity generation levels in the contiguous United States by 2050. The analysis focused on the sufficiency of the geographically diverse U.S. renewable resources to meet electricity demand over future decades, the hourly operational characteristics of the U.S. grid with high levels of variable wind and solar generation, and the potential implications of deploying high levels of renewables in the future. RE Futures focused on technical aspects of high penetration of renewable electricity; it did not focus on how to achieve such a future through policy or other measures. Given the inherent uncertainties involved with analyzing alternative long-term energy futures as well as the multiple pathways that might be taken to achieve higher levels of renewable electricity supply, RE Futures explored a range of scenarios to investigate and compare the impacts of renewable electricity penetration levels (30%–90%), future technology performance improvements, potential constraints to renewable electricity development, and future electricity demand growth assumptions. RE Futures was led by the National Renewable Energy Laboratory (NREL) and the Massachusetts Institute of Technology (MIT). Learn more at the RE Futures website. http://www.nrel.gov/analysis/re_futures/

  17. Skylab experiments. Volume 6: Mechanics. [Skylab program accomplishments for high school level education

    Science.gov (United States)

    1973-01-01

    Skylab program activities are presented in a form adapted to instruction of high school students. The overall goals of the program are discussed. The specific accomplishments of the mechanics investigations are described. The subjects involved are as follows: (1) evaluation of mobility aids, (2) mass measurement devices, and (3) space guidance crew/vehicle disturbances.

  18. High Temperature Advanced Structural Composites. Volume 2. Ceramic Matrix Composites, Fiber Processing and Properties, and Interfaces

    Science.gov (United States)

    1993-04-02

    furfural . toughness and a pseudoplasticity. the latter of treated to a higher temperature. The mamx or acetylenic resins provide simple processing...crystalline by TU/SAD and has an effective surface area of 250 m /go based on BET measurments with N2 adsorption . This solid crystallizes to high purity

  19. Development of base technology for high burnup PWR fuel improvement Volume 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yang Eun; Lee, Sang Hee; Bae, Seong Man [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center; Chung, Jin Gon; Chung, Sun Kyo; Kim, Sun Du [Korea Atomic Energy Research Inst., Daeduk (Korea, Republic of); Kim, Jae Won; Chung, Sun Kyo; Kim, Sun Du [Korea Nuclear Fuel Development Inst., Seoul (Korea, Republic of)

    1995-12-31

    Development of base technology for high burnup nuclear fuel -Development of UO{sub 2} pellet manufacturing technology -Improvement of fuel rod performance code -Improvement of plenum spring design -Study on the mechanical characteristics of fuel cladding -Organization of fuel failure mechanism Establishment of next stage R and D program (author). 226 refs., 100 figs.

  20. Renewable Electricity Futures Study. Volume 1: Exploration of High-Penetration Renewable Electricity Futures

    Energy Technology Data Exchange (ETDEWEB)

    Mai, T.; Wiser, R.; Sandor, D.; Brinkman, G.; Heath, G.; Denholm, P.; Hostick, D.J.; Darghouth, N.; Schlosser, A.; Strzepek, K.

    2012-06-01

    The Renewable Electricity Futures (RE Futures) Study investigated the challenges and impacts of achieving very high renewable electricity generation levels in the contiguous United States by 2050. The analysis focused on the sufficiency of the geographically diverse U.S. renewable resources to meet electricity demand over future decades, the hourly operational characteristics of the U.S. grid with high levels of variable wind and solar generation, and the potential implications of deploying high levels of renewables in the future. RE Futures focused on technical aspects of high penetration of renewable electricity; it did not focus on how to achieve such a future through policy or other measures. Given the inherent uncertainties involved with analyzing alternative long-term energy futures as well as the multiple pathways that might be taken to achieve higher levels of renewable electricity supply, RE Futures explored a range of scenarios to investigate and compare the impacts of renewable electricity penetration levels (30%-90%), future technology performance improvements, potential constraints to renewable electricity development, and future electricity demand growth assumptions. RE Futures was led by the National Renewable Energy Laboratory (NREL) and the Massachusetts Institute of Technology (MIT).

  1. Capabilities for managing high-volume production of electric engineering equipment at the Electrochemical Production Plant

    Energy Technology Data Exchange (ETDEWEB)

    Podlednev, V.M.

    1996-04-01

    The Electromechanical Production Plant is essentially a research center with experimental facilities and power full testing base. Major products of the plant today include heat pipes and devices of their basis of different functions and power from high temperature ranges to cryogenics. This report describes work on porous titanium and carbon-graphite current collectors, electrocatalyst synthesis, and electrocatalyst applications.

  2. Powder metallurgical high performance materials. Proceedings. Volume 2: P/M hard materials

    Energy Technology Data Exchange (ETDEWEB)

    Kneringer, G; Roedhammer, P; Wildner, H [eds.

    2001-07-01

    The proceedings of these seminars form an impressive chronicle of the continued progress in the understanding of refractory metals and cemented carbides and in their manufacture and application. There the ingenuity and assiduous work of thousands of scientists and engineers striving for progress in the field of powder metallurgy is documented in more than 2000 contributions covering some 30000 pages. The 15{sup th} Plansee Seminar was convened under the general theme 'Powder Metallurgical High Performance Materials'. Under this broadened perspective the seminar will strive to look beyond the refractory metals and cemented carbides, which remain at its focus, to novel classes of materials, such as intermetallic compounds, with potential for high temperature applications. (author)

  3. Powder metallurgical high performance materials. Proceedings. Volume 2: P/M hard materials

    International Nuclear Information System (INIS)

    Kneringer, G.; Roedhammer, P.; Wildner, H.

    2001-01-01

    The proceedings of these seminars form an impressive chronicle of the continued progress in the understanding of refractory metals and cemented carbides and in their manufacture and application. There the ingenuity and assiduous work of thousands of scientists and engineers striving for progress in the field of powder metallurgy is documented in more than 2000 contributions covering some 30000 pages. The 15 th Plansee Seminar was convened under the general theme 'Powder Metallurgical High Performance Materials'. Under this broadened perspective the seminar will strive to look beyond the refractory metals and cemented carbides, which remain at its focus, to novel classes of materials, such as intermetallic compounds, with potential for high temperature applications. (author)

  4. Advances on Propulsion Technology for High-Speed Aircraft. Volume 1

    Science.gov (United States)

    2007-03-01

    breathing propulsion in the 21st century make space travel routine and intercontinental travel as easy as intercity travel is today? This presentation...higher thermal margins. The second fluid of the cooling system travels in a closed Brayton loop. A compressor pumps the second fluid which enters the...the compressor, closing the Brayton loop. The heated fuel travels from the heat exchanger to the combustor, where it utilized I to propel the high

  5. Review of current status of high flux heat transfer techniques. Volume I. Text + Appendix A

    International Nuclear Information System (INIS)

    Bauer, W.H.; Gordon, H.S.; Lackner, H.; Mettling, J.R.; Miller, J.E.

    1980-09-01

    The scope of this work comprised two tasks. The first was to review high heat flux technology with consideration given to heat transfer panel configuration, diagnostics techniques and coolant supply. The second task was to prepare a report describing the findings of the review, to recommend the technology offering the least uncertainty for scale-up for the MFTF-B requirement and to recommend any new or perceived requirements for R and D effort

  6. High density matter in AGS, SPS and RHIC collisions: Proceedings. Volume 9

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    This 1-day workshop focused on phenomenological models regarding the specific question of the maximum energy density achievable in collisions at AGS, SPS and RHIC. The idea was to have 30-minute (or less) presentations of each model--but not the model as a whole, rather then that strongly narrowed to the above physics question. The key topics addressed were: (1) to estimate the energy density in heavy-ion collisions within a model, and to discuss its physical implications; (2) to suggest experimental observables that may confirm the correctness of a model approach--with respect to the energy density estimate; (3) to compare with existing data from AGS and SPS heavy-ion collisions, and to give predictions for the future RHIC experiments. G. Ogilvie started up the workshop with a critical summary of experimental manifestations of high-density matter at the AGS, and gave a personal outlook on RHIC physics. R. Mattiello talked about his newly developed hadron cascade model for applications to AGS and SPS collisions. Next, D. Kharzeev gave a nice introduction of the Glauber approach to high-energy collisions and illustrated the predictive power of this approach in nucleus-nucleus collisions at the SPS. It followed S. Vance with a presentation of the baryon-junction model to explain the observed baryon stopping phenomenon in collisions of heavy nuclei. S. Bass continued with a broad perspective of the UrQMD model, and provided insight into the details of the microscopic dynamical features of nuclear collisions at high energy. J. Sandweiss and J. Kapusta addressed the interesting aspect of photon production in peripherical nuclear collisions due to intense electromagnetic bremstrahlung by the highly charged, fast moving ions. Finally, H. Sorge closed up the one-day workshop with a presentation of his recent work with the RQMD model. This report consists of a summary and vugraphs of the presentations.

  7. HIGH EFFICIENCY STRUCTURAL FLOWTHROUGH ROTOR WITH ACTIVE FLAP CONTROL: VOLUME ONE: PRELIMINARY DESIGN REPORT

    Energy Technology Data Exchange (ETDEWEB)

    Zuteck, Michael D. [Zimitar, Inc.; Jackson, Kevin L. [Zimitar, Inc.; Santos, Richard A. [Zimitar, Inc.; Chow, Ray [Zimitar, Inc.; Nordenholz, Thomas R. [The California Maritime Academy; Wamble, John Lee [Zimitar, Inc.

    2015-05-16

    The Zimitar one-piece rotor primary structure is integrated, so balanced thrust and gravity loads flow through the hub region without transferring out of its composite material. Large inner rotor geometry is used since there is no need to neck down to a blade root region and pitch bearing. Rotor control is provided by a highly redundant, five flap system on each blade, sized so that easily handled standard electric linear actuators are sufficient.

  8. High density matter in AGS, SPS and RHIC collisions. Proceedings. Volume 9

    International Nuclear Information System (INIS)

    1998-01-01

    This 1-day workshop focused on phenomenological models regarding the specific question of the maximum energy density achievable in collisions at AGS, SPS and RHIC. The idea was to have 30-minute (or less) presentations of each model--but not the model as a whole, rather then that strongly narrowed to the above physics question. The key topics addressed were: (1) to estimate the energy density in heavy-ion collisions within a model, and to discuss its physical implications; (2) to suggest experimental observables that may confirm the correctness of a model approach--with respect to the energy density estimate; (3) to compare with existing data from AGS and SPS heavy-ion collisions, and to give predictions for the future RHIC experiments. G. Ogilvie started up the workshop with a critical summary of experimental manifestations of high-density matter at the AGS, and gave a personal outlook on RHIC physics. R. Mattiello talked about his newly developed hadron cascade model for applications to AGS and SPS collisions. Next, D. Kharzeev gave a nice introduction of the Glauber approach to high-energy collisions and illustrated the predictive power of this approach in nucleus-nucleus collisions at the SPS. It followed S. Vance with a presentation of the baryon-junction model to explain the observed baryon stopping phenomenon in collisions of heavy nuclei. S. Bass continued with a broad perspective of the UrQMD model, and provided insight into the details of the microscopic dynamical features of nuclear collisions at high energy. J. Sandweiss and J. Kapusta addressed the interesting aspect of photon production in peripherical nuclear collisions due to intense electromagnetic bremstrahlung by the highly charged, fast moving ions. Finally, H. Sorge closed up the one-day workshop with a presentation of his recent work with the RQMD model. This report consists of a summary and vugraphs of the presentations

  9. Intermediate photovoltaic system application experiment operational performance report. Volume 2 for Beverly High School, Beverly, MA

    Energy Technology Data Exchange (ETDEWEB)

    1981-09-01

    For the month of July 1981, performance data are listed and graphed for an intermediate photovoltaic system at a high school in Massachusetts. The energy production, incident solar energy and efficiency are given, and the daily energy production and efficiency, and energy production as a function of power and voltage are graphed. The output of the power conditioner, insolation, heating and cooling loads, temperature and wind data, and the number of freeze-thaw cycles are given. (LEW)

  10. Intermediate Photovoltaic System Application Experiment operational performance: executive summary. Volume for Beverly High School, Beverly, MA

    Energy Technology Data Exchange (ETDEWEB)

    1981-09-01

    For the momth of July 1981, performance data are given for a grid-connected 100 kW photovoltaic flat panel power system at a high school in Massachusetts. The total electrical energy produced solar energy incident on the solar cells, array and system efficiency, capacity factor and insolation are given for the month and the daily energy production and incident solar energy are graphed. (LEW)

  11. USAF Summer Research Program - 1993 High School Apprenticeship Program Final Reports, Volume 12, Armstrong Laboratory

    Science.gov (United States)

    1993-12-01

    photoelectric effect in biological substances (amino acids, proteins , or spores), a conducting metal, salt (NaCl), was tested to determine if granule...eliminating exercise before a flight, and maintaining a high protein , low bulk diet. Some leave alcohol out of their daily routine to help in the process...WISE has eight tools: Freewriting ( Dinosaur Drag), Sticky Notes, Writing Pad, Thought Log, Crossword Puzzle, Cubing, Revision, and Idea Board. In

  12. Review of current status of high flux heat transfer techniques. Volume I. Text + Appendix A

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, W.H.; Gordon, H.S.; Lackner, H.; Mettling, J.R.; Miller, J.E.

    1980-09-01

    The scope of this work comprised two tasks. The first was to review high heat flux technology with consideration given to heat transfer panel configuration, diagnostics techniques and coolant supply. The second task was to prepare a report describing the findings of the review, to recommend the technology offering the least uncertainty for scale-up for the MFTF-B requirement and to recommend any new or perceived requirements for R and D effort.

  13. HIGH EFFICIENCY STRUCTURAL FLOWTHROUGH ROTOR WITH ACTIVE FLAP CONTROL: VOLUME ZERO: OVERVIEW AND COMMERCIAL PATH

    Energy Technology Data Exchange (ETDEWEB)

    Zuteck, Michael D. [Zimitar, Inc.; Jackson, Kevin L. [Zimitar, Inc.; Santos, Richard A. [Zimitar, Inc.

    2015-05-16

    The Zimitar one-piece rotor primary structure is integrated, so balanced thrust and gravity loads flow through the hub region without transferring out of its composite material. Large inner rotor geometry is used since there is no need to neck down to a blade root region and pitch bearing. Rotor control is provided by a highly redundant, five flap system on each blade, sized so that easily handled standard electric linear actuators are sufficient.

  14. HIGH EFFICIENCY STRUCTURAL FLOWTHROUGH ROTOR WITH ACTIVE FLAP CONTROL: VOLUME TWO: INNOVATION & COST OF ENERGY

    Energy Technology Data Exchange (ETDEWEB)

    Zuteck, Michael D. [Zimitar, Inc.; Jackson, Kevin L. [Zimitar, Inc.; Santos, Richard A. [Zimitar, Inc.

    2015-05-16

    The Zimitar one-piece rotor primary structure is integrated, so balanced thrust and gravity loads flow through the hub region without transferring out of its composite material. Large inner rotor geometry is used since there is no need to neck down to a blade root region and pitch bearing. Rotor control is provided by a highly redundant, five flap system on each blade, sized so that easily handled standard electric linear actuators are sufficient.

  15. HIGH EFFICIENCY STRUCTURAL FLOWTHROUGH ROTOR WITH ACTIVE FLAP CONTROL: VOLUME THREE: MARKET & TEAM

    Energy Technology Data Exchange (ETDEWEB)

    Zuteck, Michael D. [Zimitar, Inc.; Jackson, Kevin L. [Zimitar, Inc.; Santos, Richard A. [Zimitar, Inc.

    2015-05-16

    The Zimitar one-piece rotor primary structure is integrated, so balanced thrust and gravity loads flow through the hub region without transferring out of its composite material. Large inner rotor geometry is used since there is no need to neck down to a blade root region and pitch bearing. Rotor control is provided by a highly redundant, five flap system on each blade, sized so that easily handled standard electric linear actuators are sufficient.

  16. Tomographic Particle Image Velocimetry using Pulsed, High Power LED Volume Illumination

    OpenAIRE

    Buchmann, N. A.; Willert, C.; Soria, J.

    2011-01-01

    This paper investigates the use of high-power light emitting diode (LED) illumination in Particle Image Velocimetry (PIV) as an alternative to traditional laser-based illumination. The solid-state LED devices can provide averaged radiant power in excess of 10W and by operating the LEDs with short current pulses, considerably higher than in continuous operation, light pulses of sufficient energy suitable for imaging micron-sized particles can be generated. The feasibility of this LED-based ill...

  17. Flexural Behavior of High-Volume Steel Fiber Cementitious Composite Externally Reinforced with Basalt FRP Sheet

    OpenAIRE

    Seungwon Kim; Cheolwoo Park

    2016-01-01

    High-performance fiber-reinforced cementitious composites (HPFRCCs) are characterized by unique tensile strain hardening and multiple microcracking behaviors. The HPFRCC, which demonstrates remarkable properties such as strength, ductility, toughness, durability, stiffness, and thermal resistance, is a class of fiber cement composite with fine aggregates. It can withstand tensile stresses by forming distributed microcracks owing to the embedded fibers in the concrete, which improve the energy...

  18. Evaluation of two intracavitary high-dose-rate brachytherapy devices for irradiating additional and irregularly shaped volumes of breast tissue

    International Nuclear Information System (INIS)

    Lu, Sharon M.; Scanderbeg, Daniel J.; Barna, Patrick; Yashar, William; Yashar, Catheryn

    2012-01-01

    The SAVI and Contura breast brachytherapy applicators represent 2 recent advancements in brachytherapy technology that have expanded the number of women eligible for accelerated partial breast irradiation in the treatment of early-stage breast cancer. Early clinical experience with these 2 single-entry, multichannel high-dose-rate brachytherapy devices confirms their ease of use and dosimetric versatility. However, current clinical guidelines for SAVI and Contura brachytherapy may result in a smaller or less optimal volume of treated tissue compared with traditional interstitial brachytherapy. This study evaluates the feasibility of using the SAVI and Contura to irradiate larger and irregularly shaped target volumes, approaching what is treatable with the interstitial technique. To investigate whether additional tissue can be treated, 17 patients treated with the SAVI and 3 with the Contura were selected. For each patient, the planning target volume (PTV) was modified to extend 1.1 cm, 1.3 cm, and 1.5 cm beyond the tumor bed cavity. To evaluate dose conformance to an irregularly shaped target volume, 9 patients treated with the SAVI and 3 with the Contura were selected from the original 20 patients. The following asymmetric PTV margin combinations were assessed for each patient: 1.5/0.3, 1.3/0.3, and 1.1/0.3 cm. For all patients, treatment planning was performed, adopting the National Surgical Adjuvant Breast and Bowel Project guidelines, and dosimetric comparisons were made. The 6–1 and 8–1 SAVI devices can theoretically treat a maximal tissue margin of 1.5 cm and an asymmetric PTV with margins ranging from 0.3 to 1.5 cm. The 10–1 SAVI and Contura can treat a maximal margin of 1.3 cm and 1.1 cm, respectively, and asymmetric PTV with margins ranging from 0.3–1.3 cm. Compared with the Contura, the SAVI demonstrated greater dosimetric flexibility. Risk of developing excessive hot spots increased with the size of the SAVI device. Both the SAVI and Contura

  19. The heart rate increase at the onset of high-work intensity exercise is accelerated by central blood volume loading.

    Science.gov (United States)

    Miyamoto, Tadayoshi; Oshima, Yoshitake; Ikuta, Komei; Kinoshita, Hiroshi

    2006-01-01

    Using a water immersion (WI) method, the combined effect of central blood volume (CBV) loading and work intensity on the time course of heart rate (HR) at the onset of upright dynamic exercise was investigated. Seven males cranked a cycle ergometer for 12 min using their un-immersed arms at low-, moderate- and high-work intensities, followed by a 12-min rest. For WI, the pre-exercise resting cardiac output increased by 36%, while HR decreased by 22% [from 76.8 (10.4) to 59.6 (9.8) beats/min]. WI also increased the high-frequency (HF, 0.15-0.40 Hz) component of the HR variability, suggesting an increased vagal activity. During the initial 2 min of the exercise period at low-work intensity, HR increased by 34.9 and 25.8% in the WI and control conditions, respectively. These were 117 and 73% at high-work intensity, indicating more accelerated HR with WI than the control. The plasma norepinephrine concentration increased less during high-work intensity exercise during WI, as compared to exercise during control conditions. In conclusion, the HR increase at the onset of high-work intensity exercise is accelerated by CBV loading but not at low intensity, possibly reflecting vago-sympathetic interaction and reduced baroreflex sensitivity.

  20. Comparison of high temperature gas particulate collectors for low level radwaste incinerator volume reduction systems

    International Nuclear Information System (INIS)

    Moscardini, R.L.; Johnston, J.R.; Waters, R.M.; Zievers, J.F.

    1983-01-01

    Incinerator system off-gases must be treated to prevent the release of particulates, noxious gases and radioactive elements to the environment. Fabric filters, venturi scrubbers, cyclone separators, an ceramic or metal filter candles have been used for particulate removal. Dry high temperature particulate collectors have the advantage of not creating additional liquid wastes. This paper presents a graphical comparison of different methods for filtering particles from high temperature incineration system off-gases. Eight methods of off-gas handling are compared. A much larger group may be present, but some judicious selection of different, but related systems was done for this paper based on experience with the Combustion Engineering Waste Incineration System (CE/WIS) Prototype. The eight types are: Inertial Devices, Electrostatic Precipitators (ESP), Standard Fabric Bags, Woven Ceramic Bags, Granular Beds, Sintered Metal Tubes, Felted Ceramic Bags and Ceramic Filter Candles. For high temperature LLRW particulate collection in incinerator off-gas systems, ceramic filter candles are the best overall choice

  1. High-resolution dynamic angiography using flat-panel volume CT: feasibility demonstration for neuro and lower limb vascular applications

    International Nuclear Information System (INIS)

    Mehndiratta, Amit; Rabinov, James D.; Grasruck, Michael; Liao, Eric C.; Crandell, David; Gupta, Rajiv

    2015-01-01

    This paper evaluates a prototype flat-panel volume CT (fpVCT) for dynamic in vivo imaging in a variety of neurovascular and lower limb applications. Dynamic CTA was performed on 12 patients (neuro = 8, lower limb = 4) using an fpVCT with 120 kVp, 50 mA, rotation time varying from 8 to 19 s, and field of view of 25 x 25 x 18 cm 3 . Four-dimensional data sets (i.e. 3D images over time) were reconstructed and reviewed. Dynamic CTA demonstrated sufficient spatio-temporal resolution to elucidate first-pass and recirculation dynamics of contrast bolus through neurovasclar pathologies and phasic blood flow though lower-limb vasculature and grafts. The high spatial resolution of fpVCT resulted in reduced partial volume and metal beam-hardening artefacts. This facilitated assessment of vascular lumen in the presence of calcified plaque and evaluation of fractures, especially in the presence of fixation hardware. Evaluation of arteriovenous malformation using dynamic fpVCT angiography was of limited utility. Dynamic CTA using fpVCT can visualize time-varying phenomena in neuro and lower limb vascular applications and has sufficient diagnostic imaging quality to evaluate a number of pathologies affecting these regions. (orig.)

  2. High-resolution dynamic angiography using flat-panel volume CT: feasibility demonstration for neuro and lower limb vascular applications

    Energy Technology Data Exchange (ETDEWEB)

    Mehndiratta, Amit [Massachusetts General Hospital, Department of Radiology, Harvard Medical School, Boston, MA (United States); University of Oxford, Institute of Biomedical Engineering and Keble College, Oxford (United Kingdom); Indian Institute of Technology Delhi and All India Institute of Medical Science, Centre for Biomedical Engineering, New Delhi (India); Rabinov, James D. [Massachusetts General Hospital, Interventional Neuroradiology, Harvard Medical School, Boston, MA (United States); Grasruck, Michael [Siemens Medical Solutions, Forchheim (Germany); Liao, Eric C. [Massachusetts General Hospital, Department of Plastic and Reconstructive Surgery and Center for Regenerative Medicine, Harvard Medical School, Boston, MA (United States); Crandell, David [Spaulding Rehabilitation Hospital, Department of Physical Medicine and Rehabilitation, Harvard Medical School, Charlestown, MA (United States); Gupta, Rajiv [Massachusetts General Hospital, Department of Radiology, Harvard Medical School, Boston, MA (United States)

    2015-07-15

    This paper evaluates a prototype flat-panel volume CT (fpVCT) for dynamic in vivo imaging in a variety of neurovascular and lower limb applications. Dynamic CTA was performed on 12 patients (neuro = 8, lower limb = 4) using an fpVCT with 120 kVp, 50 mA, rotation time varying from 8 to 19 s, and field of view of 25 x 25 x 18 cm{sup 3}. Four-dimensional data sets (i.e. 3D images over time) were reconstructed and reviewed. Dynamic CTA demonstrated sufficient spatio-temporal resolution to elucidate first-pass and recirculation dynamics of contrast bolus through neurovasclar pathologies and phasic blood flow though lower-limb vasculature and grafts. The high spatial resolution of fpVCT resulted in reduced partial volume and metal beam-hardening artefacts. This facilitated assessment of vascular lumen in the presence of calcified plaque and evaluation of fractures, especially in the presence of fixation hardware. Evaluation of arteriovenous malformation using dynamic fpVCT angiography was of limited utility. Dynamic CTA using fpVCT can visualize time-varying phenomena in neuro and lower limb vascular applications and has sufficient diagnostic imaging quality to evaluate a number of pathologies affecting these regions. (orig.)

  3. Impact of surgical experience on management and outcome of pancreatic surgery performed in high- and low-volume centers.

    Science.gov (United States)

    Stella, Marco; Bissolati, Massimiliano; Gentile, Daniele; Arriciati, Alessandro

    2017-09-01

    Pancreaticoduodenectomy (PD) is one of the procedures in general surgery with the highest rate of life-threatening complications. The positive impact of the volume-outcome ratio on outcomes and mortality in pancreatic surgery (PS) has led to policy-level efforts toward centralization of care for PS that is currently under evaluation by some Regional Health Services. The role of the surgeon's experience and training is still under debate. The aim of this paper is to compare the outcomes of PS by the same surgeon in a high volume (HV) and in a low volume (LV) hospital to assess whether a specific training in PS could outdo the benefits of hospital volume. 124 pancreatic resections (98 PD) were conducted by a single surgeon from 2004 to 2014 in two different Italian hospitals with different PS volumes as well as in general surgical activities. The results were retrospectively analyzed. All data regarding demographics, oncological characteristics, surgical parameters and post-operative outcomes were compared between patients operated on in the HV (group A) and LV hospital (group B). The surgical experience in the LV hospital has been then divided into a first period (group B1) and in a second period (group B2). χ 2 test or Fisher's exact test (when variables were dichotomous) was used. The unpaired t test was used to compare continuous data between the two groups. Values are expressed as n. of cases (percent) for categorical data or as mean (standard deviation) for continuous data. A p value less than 0.05 was considered as significant. From 2004 to 2014, 124 patients underwent pancreatic resection by the same surgeon: 69 in an HV hospital (group A) and 55 in an LV hospital (group B). We focused our attention on PD outcomes, 54 in group A and 44 in group B (22 in group B1 and 22 in group B2, accordingly to the aforementioned criteria). A higher incidence of ASA 3 patients, although not statistically significant, was found in group B than in group A (34 vs. 18%; p

  4. Modular, High-Volume Fuel Cell Leak-Test Suite and Process

    Energy Technology Data Exchange (ETDEWEB)

    Ru Chen; Ian Kaye

    2012-03-12

    Fuel cell stacks are typically hand-assembled and tested. As a result the manufacturing process is labor-intensive and time-consuming. The fluid leakage in fuel cell stacks may reduce fuel cell performance, damage fuel cell stack, or even cause fire and become a safety hazard. Leak check is a critical step in the fuel cell stack manufacturing. The fuel cell industry is in need of fuel cell leak-test processes and equipment that is automatic, robust, and high throughput. The equipment should reduce fuel cell manufacturing cost.

  5. Yucca Mountain, Nevada - A Proposed Geologic Repository for High-Level Radioactive Waste (Volume 1) Introduction

    International Nuclear Information System (INIS)

    R.A. Levich; J.S. Stuckless

    2006-01-01

    Yucca Mountain in Nevada represents the proposed solution to what has been a lengthy national effort to dispose of high-level radioactive waste, waste which must be isolated from the biosphere for tens of thousands of years. This chapter reviews the background of that national effort and includes some discussion of international work in order to provide a more complete framework for the problem of waste disposal. Other chapters provide the regional geologic setting, the geology of the Yucca Mountain site, the tectonics, and climate (past, present, and future). These last two chapters are integral to prediction of long-term waste isolation

  6. Yucca Mountain, Nevada - A Proposed Geologic Repository for High-Level Radioactive Waste (Volume 1) Introduction

    Energy Technology Data Exchange (ETDEWEB)

    R.A. Levich; J.S. Stuckless

    2006-09-25

    Yucca Mountain in Nevada represents the proposed solution to what has been a lengthy national effort to dispose of high-level radioactive waste, waste which must be isolated from the biosphere for tens of thousands of years. This chapter reviews the background of that national effort and includes some discussion of international work in order to provide a more complete framework for the problem of waste disposal. Other chapters provide the regional geologic setting, the geology of the Yucca Mountain site, the tectonics, and climate (past, present, and future). These last two chapters are integral to prediction of long-term waste isolation.

  7. Physics of laser fusion. Volume III. High-power pulsed lasers

    International Nuclear Information System (INIS)

    Holzrichter, J.F.; Eimerl, D.; George, E.V.; Trenholme, J.B.; Simmons, W.W.; Hunt, J.T.

    1982-09-01

    High-power pulsed lasers can deliver sufficient energy on inertial-confinement fusion (ICF) time scales (0.1 to 10 ns) to heat and compress deuterium-tritium fuel to fusion-reaction conditions. Several laser systems have been examined, including Nd:glass, CO 2 , KrF, and I 2 , for their ICF applicability. A great deal of developmental effort has been applied to the Nd:glass laser and the CO 2 gas laser systems; these systems now deliver > 10 4 J and 20 x 10 12 W to ICF targets. We are constructing the Nova Nd:glass laser at LLNL to provide > 100 kJ and > 100 x 10 12 W of 1-μm radiation for fusion experimentation in the mid-1980s. For ICF target gain > 100 times the laser input, we expect that the laser driver must deliver approx. 3 to 5 MJ of energy on a time scale of 10 to 20 ns. In this paper we review the technological status of fusion-laser systems and outline approaches to constructing high-power pulsed laser drivers

  8. Effect of High-Volume Injection, Platelet-Rich Plasma, and Sham Treatment in Chronic Midportion Achilles Tendinopathy

    DEFF Research Database (Denmark)

    Boesen, Anders Ploug; Hansen, Rudi; Boesen, Morten Ilum

    2017-01-01

    with eccentric training in chronic AT seems more effective in reducing pain, improving activity level, and reducing tendon thickness and intratendinous vascularity than eccentric training alone. HVI may be more effective in improving outcomes of chronic AT than PRP in the short term. Registration: NCT02417987......BACKGROUND: Injection therapies are often considered alongside exercise for chronic midportion Achilles tendinopathy (AT), although evidence of their efficacy is sparse. PURPOSE: To determine whether eccentric training in combination with high-volume injection (HVI) or platelet-rich plasma (PRP......) injections improves outcomes in AT. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: A total of 60 men (age, 18-59 years) with chronic (>3 months) AT were included and followed for 6 months (n = 57). All participants performed eccentric training combined with either (1) one HVI...

  9. Improvement of Oxygenation in Severe Acute Respiratory Distress Syndrome With High-Volume Continuous Veno-venous Hemofiltration.

    Science.gov (United States)

    Yang, Wenmin; Hong, Jie; Zeng, Qiyi; Tao, Jianping; Chen, Feiyan; Dang, Run; Liang, Yufeng; Wu, Zhiyuan; Yang, Yiyu

    2016-01-01

    The efficacy and therapeutic mechanisms of continuous renal replacement therapy (CRRT) for improvement of oxygenation in acute respiratory distress syndrome (ARDS) remain controversial. These questions were addressed by retrospective analysis of severe ARDS patients admitted to the pediatric intensive care unit of our hospital from 2009 to 2015 who received high-volume continuous veno-venous hemofiltration during mechanical ventilation. There was a significant improvement in partial oxygen pressure/fraction of inspired oxygen (PaO2/FiO2) 24 hours after CRRT onset compared with baseline (median change = 51.5; range = -19 to 450.5; P Improvement in oxygenation is likely related to both restoration of fluid balance and clearance of inflammatory mediators.

  10. Using high-order polynomial basis in 3-D EM forward modeling based on volume integral equation method

    Science.gov (United States)

    Kruglyakov, Mikhail; Kuvshinov, Alexey

    2018-05-01

    3-D interpretation of electromagnetic (EM) data of different origin and scale becomes a common practice worldwide. However, 3-D EM numerical simulations (modeling)—a key part of any 3-D EM data analysis—with realistic levels of complexity, accuracy and spatial detail still remains challenging from the computational point of view. We present a novel, efficient 3-D numerical solver based on a volume integral equation (IE) method. The efficiency is achieved by using a high-order polynomial (HOP) basis instead of the zero-order (piecewise constant) basis that is invoked in all routinely used IE-based solvers. We demonstrate that usage of the HOP basis allows us to decrease substantially the number of unknowns (preserving the same accuracy), with corresponding speed increase and memory saving.

  11. On-chip polarimetry for high-throughput screening of nanoliter and smaller sample volumes

    Science.gov (United States)

    Bachmann, Brian O. (Inventor); Bornhop, Darryl J. (Inventor); Dotson, Stephen (Inventor)

    2012-01-01

    A polarimetry technique for measuring optical activity that is particularly suited for high throughput screening employs a chip or substrate (22) having one or more microfluidic channels (26) formed therein. A polarized laser beam (14) is directed onto optically active samples that are disposed in the channels. The incident laser beam interacts with the optically active molecules in the sample, which slightly alter the polarization of the laser beam as it passes multiple times through the sample. Interference fringe patterns (28) are generated by the interaction of the laser beam with the sample and the channel walls. A photodetector (34) is positioned to receive the interference fringe patterns and generate an output signal that is input to a computer or other analyzer (38) for analyzing the signal and determining the rotation of plane polarized light by optically active material in the channel from polarization rotation calculations.

  12. Study of short haul high-density V/STOL transportation systems, volume 1

    Science.gov (United States)

    Solomon, H. L.

    1972-01-01

    The relative advantages of STOL aircraft concepts were examined by simulating the operations of a short haul high-density intercity STOL system set in two arenas, the California corridor and the Chicago-Detroit-Cleveland triangle, during the 1980 time period. The study was constrained to the use of three aircraft concepts designated as the deflected slipstream turboprop, externally blown flap, and augmentor wing turbofan configurations. The projected demographic, economic, travel demand, and travel characteristics of the representative arenas were identified. The STOL airline operating scenarios were then formulated and through the use of the aerospace modal split simulation program, the traveler modal choices involving alternative STOL concepts were estimated in the context of the total transportation environment for 1980. System combinations that presented the best potential for economic return and traveler acceptance were then identified for each STOL concept.

  13. Double-side illuminated titania nanotubes for high volume hydrogen generation by water splitting

    Science.gov (United States)

    Mohapatra, Susanta K.; Mahajan, Vishal K.; Misra, Mano

    2007-11-01

    A sonoelectrochemical anodization method is proposed to synthesize TiO2 nanotubular arrays on both sides of a titanium foil (TiO2/Ti/TiO2). Highly ordered TiO2 nanotubular arrays of 16 cm2 area with uniform surface distribution can be obtained using this anodization procedure. These double-sided TiO2/Ti/TiO2 materials are used as both photoanode (carbon-doped titania nanotubes) and cathode (Pt nanoparticles dispersed on TiO2 nanotubes; PtTiO2/Ti/PtTiO2) in a specially designed photoelectrochemical cell to generate hydrogen by water splitting at a rate of 38 ml h-1. The nanomaterials are characterized by FESEM, HRTEM, STEM, EDS, FFT, SAED and XPS techniques. The present approach can be used for large-scale hydrogen generation using renewable energy sources.

  14. Intermediate photovoltaic system application experiment operational performance report. Volume 7. Beverly High School, Beverly, MA

    Energy Technology Data Exchange (ETDEWEB)

    1982-04-01

    Performance data are given for a grid-connected photovoltaic power supply at a Massachusetts high school for the month of March, 1982. Data presented include: daily and monthly electrical energy produced; daily and monthly solar energy incident in the array plane; daily and monthly array efficiency; energy produced as a function of power level, voltage, cell temperature, and hour of the day; power conditioner input, output, and efficiency for two power conditioner units and for the overall power conditioning system; daily and monthly photovoltaic energy to load and the corresponding dollar value; grid to load energy from February 17 through April 5; photovoltaic system efficiency; capacity factor; daily system availability; daily and hourly insolation; heating and cooling degree days; hourly and monthly ambient temperature; hourly and monthly wind speed; wind direction distribution; number of freeze/thaw cycles; hourly cell temperature; and data acquisition mode and recording interval plot. Also included are seven summaries of site events. (LEW)

  15. Net-shape forming and properties of high volume fraction SiCp/Al composites

    International Nuclear Information System (INIS)

    Ren Shubin; Qu Xuanhui; Guo Jia; He Xinbo; Qin Mingli; Shen Xiaoyu

    2009-01-01

    High performance SiCp/Al composites have been realized their net-shape forming by use of a novel process-ceramic injection molding (CIM) for the preparation of SiC preform and pressureless infiltration of aluminum alloys. The dimension precision of prepared SiCp/Al parts could reach about ±0.3%, and their properties could also better meet the requirement of electronic packaging on the materials. In this paper, the CIM process to fabricate SiC preform and the infiltration of SiC preform by Al alloys have been discussed in detail. Additionally, the properties of prepared SiCp/Al composites have also been given research and evaluation.

  16. Research and development of a high efficiency gas-fired water heater. Volume 2. Task reports

    Energy Technology Data Exchange (ETDEWEB)

    Vasilakis, A.D.; Pearson, J.F.; Gerstmann, J.

    1980-01-01

    Design and development of a cost-effective high efficiency gas-fired water heater to attain a service efficiency of 70% (including the effect of exfiltration) and a service efficiency of 78% (excluding exfiltration) for a 75 GPD draw at a 90/sup 0/F temperature rise, with a stored water to conditioned air temperature difference of 80/sup 0/F, are described in detail. Based on concept evaluation, a non-powered natural draft water heater was chosen as the most cost-effective design to develop. The projected installed cost is $374 compared to $200 for a conventional unit. When the project water heater is compared to a conventional unit, it has a payback of 3.7 years and life cycle savings of $350 to the consumer. A prototype water heater was designed, constructed, and tested. When operated with sealed combustion, the unit has a service efficiency of 66.4% (including the effect of exfiltration) below a burner input of 32,000 Btu/h. In the open combustion configuration, the unit operated at a measured efficiency of 66.4% Btu/h (excluding exfiltration). This compares with a service efficiency of 51.3% for a conventional water heater and 61% for a conventional high efficiency unit capable of meeting ASHRAE 90-75. Operational tests showed the unit performed well with no evidence of stacking or hot spots. It met or exceeded all capacity or usage tests specified in the program test plan and met all emission goals. Future work will concentrate on designing, building, and testing pre-production units. It is anticipated that both sealed combustion and open draft models will be pursued.

  17. The effect of long-term, high-volume aerobic exercise training on postprandial lipemia and oxidative stress.

    Science.gov (United States)

    Bloomer, Richard J; Fisher-Wellman, Kelsey H; Bell, Heather K

    2010-04-01

    We have previously found no effect of moderate-volume aerobic exercise training (approximately 3 hrs*wk(-1)) on postprandial oxidative stress. It is possible that a higher volume of exercise is needed to impact postprandial oxidative stress in young, otherwise healthy individuals. Our purpose was to compare blood triglycerides (TAGs) and oxidative stress biomarkers in 10 healthy untrained and 10 healthy highly aerobically trained (eg, >or= 40 miles running*wk(-1) or >or= 150 miles cycling*wk(-1)) men and women following ingestion of a lipid meal. Blood samples were collected before (in a 10-hour fasted state), and 1, 2, 4, and 6 hours after ingestion of a lipid load (heavy whipping cream at 1 g*kg(-1)). Blood samples were analyzed for TAGs, malondialdehyde (MDA), hydrogen peroxide (H(2)O(2)), and nitrate/nitrite (NOx). No training status or interaction effects were noted for TAGs, MDA, H2O2, or NOx (P > 0.05). However, a time effect was noted for TAGs (P = 0.01), with values higher at 2 hours (67 +/- 6 mg*dL(-1)) compared with premeal (41 +/- 6 mg*dL(-1)). A time effect was also noted for H2O2 (P = 0.0001), with values higher at 2 hours (24 +/- 3 micromol*L(-1)), 4 hours (23 +/- 3 micromol*L(-1)), and 6 hours (21 +/- 3 mumol.L(-1)) compared with premeal (7 +/- 2 micromol*L(-1)). The time effect for MDA approached significance (P = 0.07), with values peaking at 4 hours post-meal (1.59 +/- 0.16 micromol*L(-1)) compared with premeal (0.99 +/- 0.15 micromol*L(-1)). These data indicate that aerobic exercise training (even when performed at a relatively high volume) does not attenuate postprandial lipemia or oxidative stress as compared with no exercise when healthy men and women consume a lipid load in the form of heavy whipping cream. Fasting TAG values may be most important in this regard. It is possible that long-term exercise may be capable of attenuating postprandial lipemia or oxidative stress in older individuals, those with chronic disease, or those with

  18. Red Blood Cell Transfusion Need for Elective Primary Posterior Lumbar Fusion in A High-Volume Center for Spine Surgery

    Science.gov (United States)

    Ristagno, Giuseppe; Beluffi, Simonetta; Tanzi, Dario; Belloli, Federica; Carmagnini, Paola; Croci, Massimo; D’Aviri, Giuseppe; Menasce, Guido; Pastore, Juan C.; Pellanda, Armando; Pollini, Alberto; Savoia, Giorgio

    2018-01-01

    (1) Background: This study evaluated the perioperative red blood cell (RBC) transfusion need and determined predictors for transfusion in patients undergoing elective primary lumbar posterior spine fusion in a high-volume center for spine surgery. (2) Methods: Data from all patients undergoing spine surgery between 1 January 2014 and 31 December 2016 were reviewed. Patients’ demographics and comorbidities, perioperative laboratory results, and operative time were analyzed in relation to RBC transfusion. Multivariate logistic regression analysis was performed to identify the predictors of transfusion. (3) Results: A total of 874 elective surgeries for primary spine fusion were performed over the three years. Only 54 cases (6%) required RBC transfusion. Compared to the non-transfused patients, transfused patients were mainly female (p = 0.0008), significantly older, with a higher ASA grade (p = 0.0002), and with lower pre-surgery hemoglobin (HB) level and hematocrit (p < 0.0001). In the multivariate logistic regression, a lower pre-surgery HB (OR (95% CI) 2.84 (2.11–3.82)), a higher ASA class (1.77 (1.03–3.05)) and a longer operative time (1.02 (1.01–1.02)) were independently associated with RBC transfusion. (4) Conclusions: In the instance of elective surgery for primary posterior lumbar fusion in a high-volume center for spine surgery, the need for RBC transfusion is low. Factors anticipating transfusion should be taken into consideration in the patient’s pre-surgery preparation. PMID:29385760

  19. Red Blood Cell Transfusion Need for Elective Primary Posterior Lumbar Fusion in A High-Volume Center for Spine Surgery

    Directory of Open Access Journals (Sweden)

    Giuseppe Ristagno

    2018-01-01

    Full Text Available (1 Background: This study evaluated the perioperative red blood cell (RBC transfusion need and determined predictors for transfusion in patients undergoing elective primary lumbar posterior spine fusion in a high-volume center for spine surgery. (2 Methods: Data from all patients undergoing spine surgery between 1 January 2014 and 31 December 2016 were reviewed. Patients’ demographics and comorbidities, perioperative laboratory results, and operative time were analyzed in relation to RBC transfusion. Multivariate logistic regression analysis was performed to identify the predictors of transfusion. (3 Results: A total of 874 elective surgeries for primary spine fusion were performed over the three years. Only 54 cases (6% required RBC transfusion. Compared to the non-transfused patients, transfused patients were mainly female (p = 0.0008, significantly older, with a higher ASA grade (p = 0.0002, and with lower pre-surgery hemoglobin (HB level and hematocrit (p < 0.0001. In the multivariate logistic regression, a lower pre-surgery HB (OR (95% CI 2.84 (2.11–3.82, a higher ASA class (1.77 (1.03–3.05 and a longer operative time (1.02 (1.01–1.02 were independently associated with RBC transfusion. (4 Conclusions: In the instance of elective surgery for primary posterior lumbar fusion in a high-volume center for spine surgery, the need for RBC transfusion is low. Factors anticipating transfusion should be taken into consideration in the patient’s pre-surgery preparation.

  20. On fully multidimensional and high order non oscillatory finite volume methods, I

    International Nuclear Information System (INIS)

    Lafon, F.

    1992-11-01

    A fully multidimensional flux formulation for solving nonlinear conservation laws of hyperbolic type is introduced to perform calculations on unstructured grids made of triangular or quadrangular cells. Fluxes are computed across dual median cells with a multidimensional 2D Riemann Solver (R2D Solver) whose intermediate states depend on either a three (on triangle R2DT solver) of four (on quadrangle, R2DQ solver) state solutions prescribed on the three or four sides of a gravity cell. Approximate Riemann solutions are computed via a linearization process of Roe's type involving multidimensional effects. Moreover, a monotonous scheme using stencil and central Lax-Friedrichs corrections on sonic curves are built in. Finally, high order accurate ENO-like (Essentially Non Oscillatory) reconstructions using plane and higher degree polynomial limitations are defined in the set up of finite element Lagrange spaces P k and Q k for k≥0, on triangles and quadrangles, respectively. Numerical experiments involving both linear and nonlinear conservation laws to be solved on unstructured grids indicate the ability of our techniques when dealing with strong multidimensional effects. An application to Euler's equations for the Mach three step problem illustrates the robustness and usefulness of our techniques using triangular and quadrangular grids. (Author). 33 refs., 13 figs

  1. Intermediate photovoltaic system application experiment operational performance report. Volume 6 for Beverly High School, Beverly, MA

    Energy Technology Data Exchange (ETDEWEB)

    1982-03-01

    Performance data are given for the month of February, 1982 for a photovoltaic power supply at a Massachusetts high school. Data given include: monthly and daily electrical energy yield; monthly and daily insolation; monthly and daily array efficiency; energy production as a function of power level, voltage, cell temperature, and hour of day; insolation as a function of hour of the day; input, output and efficiency for each of two power conditioning units and for the total power conditioning system; energy supplied to the load by the photovoltaic system and by the grid; photovoltaic system efficiency; dollar value of the energy supplied by the photovoltaic system; capacity factor; daily photovoltaic energy to load; daily system availability and hours of daylight; heating and cooling degree days; hourly cell temperature, ambient temperature, wind speed, and insolation; average monthly wind speed; wind direction distribution; and daily data acquisition mode and recording interval plot. Also included are four site event report summaries, one involving hardware/maintenance for a power conditioning inverter, and the other three involving operations. (LEW)

  2. Intermediate photovoltaic system application experiment operational performance report. Volume 5 for Beverly High School, Beverly, MA

    Energy Technology Data Exchange (ETDEWEB)

    1982-02-01

    Performance data are presented for the month of January, 1982 for a grid-connected photovoltaic power supply at a Massachusetts high school. Data presented include: monthly and daily electrical energy produced; monthly and daily solar energy incident on the array; monthly and daily array efficiency; plots of energy produced as a function of power level, voltage, cell temperature and time of day; power conditioner input, output and efficiency for each of two individual units and for the total power conditioning system; photovoltaic system efficiency; capacity factor; PV system to load and grid to load energies and corresponding dollar values; daily energy supplied to the load by the PV system; daily PV system availability; monthly and hourly insolation; monthly and hourly temperature average; monthly and hourly wind speed; wind direction distribution; average heating and cooling degree days; number of freeze/thaw cycles; and the data acquisition mode and recording interval plot. Also included are summaries of two problems with the operating data acquisition system. (LEW)

  3. High-level waste borosilicate glass a compendium of corrosion characteristics. Volume 1

    International Nuclear Information System (INIS)

    Cunnane, J.C.

    1994-03-01

    Current plans call for the United States Department of Energy (DOE) to start up facilities for vitrification of high-level radioactive waste (HLW) stored in tanks at the Savannah River Site, Aiken, South Carolina, in 1995; West Valley Demonstration Project, West Valley, New York, in 1996; and at the Hanford Site, Richland, Washington, after the year 2000. The product from these facilities will be canistered HLW borosilicate glass, which will be stored, transported, and eventually disposed of in a geologic repository. The behavior of this glass waste product, under the range of likely service conditions, is the subject of considerable scientific and public interest. Over the past few decades, a large body of scientific information on borosilicate waste glass has been generated worldwide. The intent of this document is to consolidate information pertaining to our current understanding of waste glass corrosion behavior and radionuclide release. The objective, scope, and organization of the document are discussed in Section 1.1, and an overview of borosilicate glass corrosion is provided in Section 1.2. The history of glass as a waste form and the international experience with waste glass are summarized in Sections 1.3 and 1.4, respectively

  4. High Temperature Growth of Graphene from Cobalt Volume: Effect on Structural Properties

    Directory of Open Access Journals (Sweden)

    Giampiero Amato

    2018-02-01

    Full Text Available Several transition metals other than the largely used Cu and Ni can be, in principle, employed to catalyze carbon precursors for the chemical vapor deposition of graphene, because the thermodynamics of their alloying with carbon is well known. For example, the wealth of information in the Co-C phase diagram can be used to predict the properties of graphene grown in this way. It is, in fact, expected that growth occurs at a temperature higher than in Ni, with beneficial consequences to the mechanical and electronic properties of the final product. In this work, the growth of graphene onto Co film is presented together with an extensive Raman characterization of the structural properties of the material so far obtained. Previous results reporting the full coverage with negligible defective areas, in spite of discontinuities in the underlying metal, are confirmed, together with the occurrence of strain in the graphene sheet. Strain is deeply investigated in this work, in view of possible employment in engineering the material properties. The observed strain is ascribed to the high thermal mismatch with the substrate, even if an effect of the crystallographic transition of Co cannot be excluded.

  5. HIIT enhances endurance performance and aerobic characteristics more than high-volume training in trained rowers.

    Science.gov (United States)

    Ní Chéilleachair, Niamh J; Harrison, Andrew J; Warrington, Giles D

    2017-06-01

    This study compared the effects of long slow distance training (LSD) with high-intensity interval training (HIIT) in rowers. Nineteen well-trained rowers performed three tests before and after an 8-week training intervention: (1) 2000 m time trial; (2) seven-stage incremental step test to determine maximum oxygen uptake ([Formula: see text]O 2max ), power output at [Formula: see text]O 2max (W[Formula: see text]O 2max ), peak power output (PPO), rowing economy and blood lactate indices and (3) seven-stroke power-output test to determine maximal power output (W max ) and force (F max ). After baseline testing, participants were randomly assigned either to a HIIT or LSD group. The LSD comprised 10 weekly aerobic sessions. The HIIT also comprised 10 weekly sessions: 8 aerobic and 2 HIIT. The HIIT sessions comprised 6-8 × 2.5 min intervals at 100% PPO with recovery time based on heart rate (HR) returning to 70% HR max . Results demonstrated that the HIIT produced greater improvement in 2000 m time trial performance than the LSD (effect size (ES) = 0.25). Moreover, the HIIT produced greater improvements in [Formula: see text]O 2max (ES = 0.95, P = 0.035) and power output at lactate threshold (W LT ) (ES = 1.15, P = 0.008). Eight weeks of HIIT performed at 100% PPO is more effective than LSD in improving performance and aerobic characteristics in well-trained rowers.

  6. High Resolution DNS of Turbulent Flows using an Adaptive, Finite Volume Method

    Science.gov (United States)

    Trebotich, David

    2014-11-01

    We present a new computational capability for high resolution simulation of incompressible viscous flows. Our approach is based on cut cell methods where an irregular geometry such as a bluff body is intersected with a rectangular Cartesian grid resulting in cut cells near the boundary. In the cut cells we use a conservative discretization based on a discrete form of the divergence theorem to approximate fluxes for elliptic and hyperbolic terms in the Navier-Stokes equations. Away from the boundary the method reduces to a finite difference method. The algorithm is implemented in the Chombo software framework which supports adaptive mesh refinement and massively parallel computations. The code is scalable to 200,000 + processor cores on DOE supercomputers, resulting in DNS studies at unprecedented scale and resolution. For flow past a cylinder in transition (Re = 300) we observe a number of secondary structures in the far wake in 2D where the wake is over 120 cylinder diameters in length. These are compared with the more regularized wake structures in 3D at the same scale. For flow past a sphere (Re = 600) we resolve an arrowhead structure in the velocity in the near wake. The effectiveness of AMR is further highlighted in a simulation of turbulent flow (Re = 6000) in the contraction of an oil well blowout preventer. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Advanced Scientific Computing Research, Applied Mathematics program under Contract Number DE-AC02-05-CH11231.

  7. High-volume use of self-cementing spray dry absorber material for structural applications

    Science.gov (United States)

    Riley, Charles E.

    Spray dry absorber (SDA) material, or spray dryer ash, is a byproduct of energy generation by coal combustion and sulfur emissions controls. Like any resource, it ought to be used to its fullest potential offsetting as many of the negative environmental impacts of coal combustion as possible throughout its lifecycle. Its cementitious and pozzolanic properties suggest it be used to augment or replace another energy and emissions intensive product: Portland cement. There is excellent potential for spray dryer ash to be used beneficially in structural applications, which will offset CO2 emissions due to Portland cement production, divert landfill waste by further utilizing a plentiful coal combustion by-product, and create more durable and sustainable structures. The research into beneficial use applications for SDA material is relatively undeveloped and the material is highly underutilized. This dissertation explored a specific self-cementing spray dryer ash for use as a binder in structural materials. Strength and stiffness properties of hydrated spray dryer ash mortars were improved by chemical activation with Portland cement and reinforcement with polymer fibers from automobile tire recycling. Portland cement at additions of five percent of the cementitious material was found to function effectively as an activating agent for spray dryer ash and had a significant impact on the hardened properties. The recycled polymer fibers improved the ductility and toughness of the material in all cases and increased the compressive strength of weak matrix materials like the pure hydrated ash. The resulting hardened materials exhibited useful properties that were sufficient to suggest that they be used in structural applications such as concrete, masonry block, or as a hydraulic cement binder. While the long-term performance characteristics remain to be investigated, from an embodied-energy and carbon emissions standpoint the material investigated here is far superior to

  8. Effect of volume ratio of liquid to solid on the interfacial microstructure and mechanical properties of high chromium cast iron and medium carbon steel bimetal

    International Nuclear Information System (INIS)

    Xiong Bowen; Cai Changchun; Lu Baiping

    2011-01-01

    Highlights: → Volume ratio of liquid to solid affects significantly the interfacial microstructure. → Elemental diffusion activity is increased by increasing volume ratio. → Mechanical property is improved by increasing volume ratio. - Abstract: The high chromium cast iron and medium carbon steel bimetal was fabricated by liquid-solid casting technology. The effect of volume ratios of liquid to solid (6:1, 10:1 and 12:1) on the interfacial microstructure and mechanical properties of bimetal was investigated. The interfacial microstructure was analyzed using scanning electron microscope (SEM) and transmission electron microscope (TEM). The shear strength and microhardness in as-cast condition were studied at room temperature. The results show that the volume ratios of liquid to solid affect significantly the interfacial microstructure. When liquid-solid volume ratio was 6:1, the unbonded region was detected in interface region because the imported heat energy cannot support effectively the diffusion of element, whereas, when liquid-solid volume ratios reach 10:1 and 12:1, a sound interfacial microstructure was achieved by the diffusion of C, Cr, Mo, Cu and Mn, and metallurgical bonding without unbonded region, void and hole, etc. was detected. With the increase of liquid-solid volume ratio, the elemental diffusion activity improves, resulting in the increase of width of interface transition region. At the same distance from interface, with the increase of liquid-solid volume ratio, the microhardness is degraded in HCCI, but increased in MCS. The shear strength is also improved with the increase of liquid-solid volume ratio.

  9. Fiber Fabry-Perot Force Sensor with Small Volume and High Performance for Assessing Fretting Damage of Steam Generator Tubes.

    Science.gov (United States)

    Huang, Peijian; Wang, Ning; Li, Junying; Zhu, Yong; Zhang, Jie

    2017-12-13

    Measuring the radial collision force between the steam generator tube (SGT) and the tube support plate (TSP) is essential to assess the fretting damage of the SGT. In order to measure the radial collision force, a novel miniaturized force sensor based on fiber Fabry-Perot (F-P) was designed, and the principle and characteristics of the sensor were analyzed in detail. Then, the F-P force sensor was successfully fabricated and calibrated, and the overall dimensions of the encapsulated fiber F-P sensor were 17 mm × 5 mm × 3 mm (L × W × H). The sensor works well in humid, high pressure (10 MPa), high temperature (350 °C), and vibration (40 kHz) environments. Finally, the F-P force sensors were installed in a 1:1 steam generator test loop, and the radial collision force signals between the SGT and the TSP were obtained. The experiments indicated that the F-P sensor with small volume and high performance could help in assessing the fretting damage of the steam generator tubes.

  10. High-temperature, large-volume, lavalike ash-flow tuffs without calderas in southwestern Idaho

    Science.gov (United States)

    Ekren, E.B.; McIntyre, David H.; Bennett, Earl H.

    1984-01-01

    Rhyolitic rocks were erupted from vents in and adjacent to the Owyhee Mountains and Owyhee Plateau of southwestern Idaho from 16 m.y. ago to about 10 m.y. ago. They were deposited on a highly irregular surface developed on a variety of basement rocks that include granitic rocks of Cretaceous age, quartz latite and rhyodacite tuffs and lava flows of Eocene age, andesitic and basaltic lava flows of Oligocene age, and latitic and basaltic lava flows of early Miocene age. The rhyolitic rocks are principally welded tuffs that, regardless of their source, have one feature in common-namely internal characteristics indicating en-masse, viscous lavalike flowage. The flowage features commonly include considerable thicknesses of flow breccia at the bases of various cooling units. On the basis of the tabular nature of the rhyolitic deposits, their broad areal extents, and the local preservation of pyroclastic textures at the bases, tops, and distal ends of some of the deposits, we have concluded that the rocks were emplaced as ash flows at extremely high temperatures and that they coalesced to liquids before final emplacement and cooling. Temperatures of l090?C and higher are indicated by iron-titanium oxide compositions. Rhyolites that are about 16 m.y. old are preserved mostly in the downdropped eastern and western flanks of the Silver City Range and they are inferred to have been erupted from the Silver City Range. They rarely contain more than about 2 percent phenocrysts that consist of quartz and subequal amounts of plagioclase and alkali feldspar; commonly, they contain biotite, and they are the only rhyolitic rocks in the area to do so. The several rhyolitic units that are 14 m.y. to about 10 m.y. old contain only pyroxene-principally ferriferous and intermediate pigeonites-as mafic constituents. The rhyolites of the Silver City Range comprise many cooling units, none of which can be traced for great distances. Rocks erupted from the Owyhee Plateau include two sequences

  11. High baseline left ventricular and systolic volume may identify patients at risk of chemotherapy-induced cardiotoxicity

    International Nuclear Information System (INIS)

    Atiar Rahman; Alex Gedevanishvili; Seham Ali; Elma G Briscoe; Vani Vijaykumar

    2004-01-01

    contribute to cardiac toxicity, but neither low baseline peak filling rates nor left ventricular en d diastolic volume predicted future progression to chemotherapy induced cardiotoxicity. Summary: We conclude that high baseline left ventricular end systolic volumes may identify patients at risk of chemotherapy-induced cardiotoxicity, this parameter should be carefully evaluated prior to initiation for chemotherapy. (authors)

  12. Effects of low-volume high-intensity interval training in a community setting: a pilot study.

    Science.gov (United States)

    Reljic, Dejan; Wittmann, Felix; Fischer, Joachim E

    2018-06-01

    High-intensity interval training (HIIT) is emerging as an effective and time-efficient exercise strategy for health promotion. However, most HIIT studies are conducted in laboratory settings and evidence regarding the efficacy of time-efficient "low-volume" HIIT is based mainly on demanding "all-out" protocols. Thus, the aim of this pilot study was to assess the feasibility and efficacy of two low-volume (≤ 30 min time-effort/week), non-all-out HIIT protocols, performed 2 ×/week over 8 weeks in a community-based fitness centre. Thirty-four sedentary men and women were randomised to either 2 × 4-min HIIT (2 × 4-HIIT) or 5 × 1-min HIIT (5 × 1-HIIT) at 85-95% maximal heart rate (HR max ), or an active control group performing moderate-intensity continuous training (MICT, 76 min/week) at 65-75% HR max . The exercise protocols were well tolerated and no adverse events occurred. 2 × 4-HIIT and 5 × 1-HIIT exhibited lower dropout rates (17 and 8 vs. 30%) than MICT. All training modes improved VO 2max (2 × 4-HIIT: + 20%, P HIIT: + 27%, P HIIT protocols required 60% less time commitment. Both HIIT protocols and MICT had positive impact on cholesterol profiles. Only 5 × 1-HIIT significantly improved waist circumference (P HIIT can be feasibly implemented in a community-based setting. Moreover, our data suggest that practical (non-all-out) HIIT that requires as little as 30 min/week, either performed as 2 × 4-HIIT or 5 × 1-HIIT, may induce significant improvements in VO 2max and cardiometabolic risk markers.

  13. Variation in critical care unit admission rates and outcomes for patients with acute coronary syndromes or heart failure among high- and low-volume cardiac hospitals.

    Science.gov (United States)

    van Diepen, Sean; Bakal, Jeffrey A; Lin, Meng; Kaul, Padma; McAlister, Finlay A; Ezekowitz, Justin A

    2015-02-27

    Little is known about cross-hospital differences in critical care units admission rates and related resource utilization and outcomes among patients hospitalized with acute coronary syndromes (ACS) or heart failure (HF). Using a population-based sample of 16,078 patients admitted to a critical care unit with a primary diagnosis of ACS (n=14,610) or HF (n=1467) between April 1, 2003 and March 31, 2013 in Alberta, Canada, we stratified hospitals into high (>250), medium (200 to 250), or low (<200) volume based on their annual volume of all ACS and HF hospitalization. The percentage of hospitalized patients admitted to critical care units varied across low, medium, and high-volume hospitals for both ACS and HF as follows: 77.9%, 81.3%, and 76.3% (P<0.001), and 18.0%, 16.3%, and 13.0% (P<0.001), respectively. Compared to low-volume units, critical care patients with ACS and HF admitted to high-volume hospitals had shorter mean critical care stays (56.6 versus 95.6 hours, P<0.001), more critical care procedures (1.9 versus 1.2 per patient, <0.001), and higher resource-intensive weighting (2.8 versus 1.5, P<0.001). No differences in in-hospital mortality (5.5% versus 6.2%, adjusted odds ratio 0.93; 95% CI, 0.61 to 1.41) were observed between high- and low-volume hospitals; however, 30-day cardiovascular readmissions (4.6% versus 6.8%, odds ratio 0.77; 95% CI, 0.60 to 0.99) and cardiovascular emergency-room visits (6.6% versus 9.5%, odds ratio 0.80; 95% CI, 0.69 to 0.94) were lower in high-volume compared to low-volume hospitals. Outcomes stratified by ACS or HF admission diagnosis were similar. Cardiac patients hospitalized in low-volume hospitals were more frequently admitted to critical care units and had longer hospitals stays despite lower resource-intensive weighting. These findings may provide opportunities to standardize critical care utilization for ACS and HF patients across high- and low-volume hospitals. © 2015 The Authors. Published on behalf of the American

  14. Comparison of affective responses during and after low volume high-intensity interval exercise, continuous moderate- and continuous high-intensity exercise in active, untrained, healthy males.

    Science.gov (United States)

    Niven, Ailsa; Thow, Jacqueline; Holroyd, Jack; Turner, Anthony P; Phillips, Shaun M

    2018-09-01

    This study compared affective responses to low volume high-intensity interval exercise (HIIE), moderate-intensity continuous exercise (MICE) and high-intensity continuous exercise (HICE). Twelve untrained males ([Formula: see text] 48.2 ± 6.7 ml·kg -1 ·min -1 ) completed MICE (30 min cycle at 85% of ventilatory threshold (VT)), HICE (cycle at 105% of VT matched with MICE for total work), and HIIE (10 x 6 s cycle sprints with 60 s recovery). Affective valence and perceived activation were measured before exercise, post warm-up, every 20% of exercise time, and 1, 5, 10, and 15 min post-exercise. Affective valence during exercise declined by 1.75 ± 2.42, 1.17 ± 1.99, and 0.42 ± 1.38 units in HICE, HIIE, and MICE, respectively, but was not statistically influenced by trial (P = 0.35), time (P = 0.06), or interaction effect (P = 0.08). Affective valence during HICE and HIIE was consistently less positive than MICE. Affective valence post-exercise was not statistically influenced by trial (P = 0.10) and at 5 min post-exercise exceeded end-exercise values (P = 0.048). Circumplex profiles showed no negative affect in any trial. Affective responses to low volume HIIE are similar to HICE but remain positive and rebound rapidly, suggesting it may be a potential alternative exercise prescription.

  15. Acute response of circulating vascular regulating microRNAs during and after high-intensity and high-volume cycling in children

    Directory of Open Access Journals (Sweden)

    Yvonne eKilian

    2016-03-01

    Full Text Available Aim: The aim of the present study was to analyze the response of vascular circulating microRNAs (miRNAs; miR-16, miR-21, miR-126 and the VEGF mRNA following an acute bout of HIIT and HVT in children. Methods: Twelve healthy competitive young male cyclists (14.4 ± 0.8 yrs; 57.9 ± 9.4 ml·min-1·kg-1 peak oxygen uptake performed one session of high intensity 4x4 min intervals (HIIT at 90-95% peak power output, each interval separated by 3 min of active recovery, and one high volume session (HVT consisting of a constant load exercise for 90 min at 60% peak power output. Capillary blood from the earlobe was collected under resting conditions, during exercise (d1 = 20 min, d2 = 30 min, d3 = 60 min, and 0, 30, 60, 180 min after the exercise to determine miR-16, -21, -126 and VEGF mRNA.Results: HVT significantly increased miR-16 and miR-126 during and after the exercise compared to pre values, whereas HIIT showed no significant influence on the miRNAs compared to pre values. VEGF mRNA significantly increased during and after HIIT (d1, 30`, 60`, 180` and HVT (d3, 0`, 60`. Conclusion: Results of the present investigation suggest a volume dependent exercise regulation of vascular regulating miRNAs (miR-16, miR-21, miR-126 in children. In line with previous data, our data show that acute exercise can alter circulating miRNAs profiles that might be used as novel biomarkers to monitor acute and chronic changes due to exercise in various tissues.

  16. Quest to validate and define performance for the high volume metallic stator PCP at 250 degrees Celsius

    Energy Technology Data Exchange (ETDEWEB)

    Noonan, S.G. [ConocoPhillips Co., Houston, TX (United States); Klaczek, W.; Piers, K. [C-FER Technologies, Edmonton, AB (Canada); Seince, L. [PCM USA Inc., Houston, TX (United States); Jahn, S. [Kudu Industries, Calgary, AB (Canada)

    2008-10-15

    ConocoPhillips has been searching for a high volume artificial lift system that will reliably operate in a 250 degree Celsius downhole environment to meet the needs of steam assisted gravity drainage (SAGD) operations. This paper described the complexity of building and operating a high temperature flow loop rated for 250 degrees Celsius. It also described the lessons learned while upgrading an existing flow loop, from the initial design, procurement and construction through to the final commissioning phases. The paper described the issues encountered with the first artificial lit system tested at 250 degrees Celsius. The system consisted of a metallic progressing cavity pump system rated for 6919 barrels per day at 500 rotations per minute. The final upgraded capabilities of the flow loop were also listed. Images of the upgraded flow loop were also provided. It was concluded that the test program not only served to validate and define the pump's performance, but also provided valuable lessons on the completion configuration and operational procedures. Testing new artificial lift technology in a controlled flow loop, rather than in field installation, provided the opportunity to test these pumping systems under a large variety of conditions to truly understand the performance and limitations of each pump. 3 refs., 1 tab., 5 figs.

  17. High Resolution 3-D Finite-Volume Coastal Ocean Modeling in Lower Campbell River and Discovery Passage, British Columbia, Canada

    Directory of Open Access Journals (Sweden)

    Yuehua Lin

    2014-03-01

    Full Text Available The 3-D unstructured-grid, Finite-Volume Coastal Ocean Model (FVCOM was used to simulate the flows in Discovery Passage including the adjoining Lower Campbell River, British Columbia, Canada. Challenges in the studies include the strong tidal currents (e.g., up to 7.8 m/s in Seymour Narrows and tailrace discharges, small-scale topographic features and steep bottom slopes, and stratification affected by the Campbell River freshwater discharges. Two applications of high resolution 3-D FVCOM modeling were conducted. One is for the Lower Campbell River extending upstream as far as the John Hart Hydroelectric dam. The horizontal resolution varies from 0.27 m to 32 m in the unstructured triangular mesh to resolve the tailrace flow. The bottom elevation decreases ~14 m within the distance of ~1.4 km along the river. This pioneering FVCOM river modeling demonstrated a very good performance in simulating the river flow structures. The second application is to compute ocean currents immediately above the seabed along the present underwater electrical cable crossing routes across Discovery Passage. Higher resolution was used near the bottom with inter-layer spacing ranging from 0.125 to 0.0005 of total water depth. The model behaves very well in simulating the strong tidal currents in the area at high resolution in both the horizontal and vertical. One year maximum near bottom tidal current along the routes was then analyzed using the model results.

  18. Progressive Decline in Hippocampal CA1 Volume in Individuals at Ultra-High-Risk for Psychosis Who Do Not Remit: Findings from the Longitudinal Youth at Risk Study.

    Science.gov (United States)

    Ho, New Fei; Holt, Daphne J; Cheung, Mike; Iglesias, Juan Eugenio; Goh, Alex; Wang, Mingyuan; Lim, Joseph Kw; de Souza, Joshua; Poh, Joann S; See, Yuen Mei; Adcock, Alison R; Wood, Stephen J; Chee, Michael Wl; Lee, Jimmy; Zhou, Juan

    2017-05-01

    Most individuals identified as ultra-high-risk (UHR) for psychosis do not develop frank psychosis. They continue to exhibit subthreshold symptoms, or go on to fully remit. Prior work has shown that the volume of CA1, a subfield of the hippocampus, is selectively reduced in the early stages of schizophrenia. Here we aimed to determine whether patterns of volume change of CA1 are different in UHR individuals who do or do not achieve symptomatic remission. Structural MRI scans were acquired at baseline and at 1-2 follow-up time points (at 12-month intervals) from 147 UHR and healthy control subjects. An automated method (based on an ex vivo atlas of ultra-high-resolution hippocampal tissue) was used to delineate the hippocampal subfields. Over time, a greater decline in bilateral CA1 subfield volumes was found in the subgroup of UHR subjects whose subthreshold symptoms persisted (n=40) and also those who developed clinical psychosis (n=12), compared with UHR subjects who remitted (n=41) and healthy controls (n=54). No baseline differences in volumes of the overall hippocampus or its subfields were found among the groups. Moreover, the rate of volume decline of CA1, but not of other hippocampal subfields, in the non-remitters was associated with increasing symptom severity over time. Thus, these findings indicate that there is deterioration of CA1 volume in persistently symptomatic UHR individuals in proportion to symptomatic progression.

  19. Industrial based volume manufacturing of lightweight aluminium alloy panel components with high-strength and complex-shape for car body and chassis structures

    Science.gov (United States)

    Anyasodor, Gerald; Koroschetz, Christian

    2017-09-01

    To achieve the high volume manufacture of lightweight passenger cars at economic cost as required in the automotive industry, low density materials and new process route will be needed. While high strength aluminium alloy grades: AA7075 and AA6082 may provide the alternative material solution, hot stamping process used for high-strength and ultrahigh strength steels such as boron steel 22mnb5 can enable the volume manufacture of panel components with high-strength and complex-shape for car body and chassis structures. These aluminium alloy grades can be used to manufacture panel components with possible yield strengths ≥ 500 MPa. Due to the differences in material behaviors, hot stamping process of 22mnb5 cannot be directly applied to high strength aluminium alloy grades. Despite recorded successes in laboratories, researches and niche hot forming processes of high strength aluminium alloy grades, not much have been achieved for adequate and efficient volume manufacturing system applicable in the automotive industry. Due to lack of such system and based on expert knowledge in hot stamping production-line, AP&T presents in this paper a hot stamping processing route for high strength aluminium alloys been suitable for production-line development and volume manufacturing.

  20. Moderately high frequency ventilation with a conventional ventilator allows reduction of tidal volume without increasing mean airway pressure.

    Science.gov (United States)

    Cordioli, Ricardo Luiz; Park, Marcelo; Costa, Eduardo Leite Vieira; Gomes, Susimeire; Brochard, Laurent; Amato, Marcelo Britto Passos; Azevedo, Luciano Cesar Pontes

    2014-12-01

    The aim of this study was to explore if positive-pressure ventilation delivered by a conventional ICU ventilator at a moderately high frequency (HFPPV) allows a safe reduction of tidal volume (V T) below 6 mL/kg in a porcine model of severe acute respiratory distress syndrome (ARDS) and at a lower mean airway pressure than high-frequency oscillatory ventilation (HFOV). This is a prospective study. In eight pigs (median weight 34 [29,36] kg), ARDS was induced by pulmonary lavage and injurious ventilation. The animals were ventilated with a randomized sequence of respiratory rates: 30, 60, 90, 120, 150, followed by HFOV at 5 Hz. At each step, V T was adjusted to allow partial pressure of arterial carbon dioxide (PaCO2) to stabilize between 57 and 63 mmHg. Data are shown as median [P25th,P75th]. After lung injury, the PaO2/FiO2 (P/F) ratio was 92 [63,118] mmHg, pulmonary shunt 26 [17,31]%, and static compliance 11 [8,14] mL/cmH2O. Positive end-expiratory pressure (PEEP) was 14 [10,17] cmH2O. At 30 breaths/min, V T was higher than 6 (7.5 [6.8,10.2]) mL/kg, but at all higher frequencies, V T could be reduced and PaCO2 maintained, leading to reductions in plateau pressures and driving pressures. For frequencies of 60 to 150/min, V T progressively fell from 5.2 [5.1,5.9] to 3.8 [3.7,4.2] mL/kg (p mechanics, auto-PEEP generation, hemodynamics, or gas exchange. Mean airway pressure was maintained constant and was increased only during HFOV. During protective mechanical ventilation, HFPPV delivered by a conventional ventilator in a severe ARDS swine model safely allows further tidal volume reductions. This strategy also allowed decreasing airway pressures while maintaining stable PaCO2 levels.

  1. Divergence-free MHD on unstructured meshes using high order finite volume schemes based on multidimensional Riemann solvers

    Science.gov (United States)

    Balsara, Dinshaw S.; Dumbser, Michael

    2015-10-01

    Several advances have been reported in the recent literature on divergence-free finite volume schemes for Magnetohydrodynamics (MHD). Almost all of these advances are restricted to structured meshes. To retain full geometric versatility, however, it is also very important to make analogous advances in divergence-free schemes for MHD on unstructured meshes. Such schemes utilize a staggered Yee-type mesh, where all hydrodynamic quantities (mass, momentum and energy density) are cell-centered, while the magnetic fields are face-centered and the electric fields, which are so useful for the time update of the magnetic field, are centered at the edges. Three important advances are brought together in this paper in order to make it possible to have high order accurate finite volume schemes for the MHD equations on unstructured meshes. First, it is shown that a divergence-free WENO reconstruction of the magnetic field can be developed for unstructured meshes in two and three space dimensions using a classical cell-centered WENO algorithm, without the need to do a WENO reconstruction for the magnetic field on the faces. This is achieved via a novel constrained L2-projection operator that is used in each time step as a postprocessor of the cell-centered WENO reconstruction so that the magnetic field becomes locally and globally divergence free. Second, it is shown that recently-developed genuinely multidimensional Riemann solvers (called MuSIC Riemann solvers) can be used on unstructured meshes to obtain a multidimensionally upwinded representation of the electric field at each edge. Third, the above two innovations work well together with a high order accurate one-step ADER time stepping strategy, which requires the divergence-free nonlinear WENO reconstruction procedure to be carried out only once per time step. The resulting divergence-free ADER-WENO schemes with MuSIC Riemann solvers give us an efficient and easily-implemented strategy for divergence-free MHD on

  2. Ink-Jet Printing of Gluconobacter oxydans: Micropatterned Coatings As High Surface-to-Volume Ratio Bio-Reactive Coatings

    Directory of Open Access Journals (Sweden)

    Marcello Fidaleo

    2013-12-01

    Full Text Available We formulated a latex ink for ink-jet deposition of viable Gram-negative bacterium Gluconobacter oxydans as a model adhesive, thin, highly bio-reactive microstructured microbial coating. Control of G. oxydans latex-based ink viscosity by dilution with water allowed ink-jet piezoelectric droplet deposition of 30 × 30 arrays of two or three droplets/dot microstructures on a polyester substrate. Profilometry analysis was used to study the resulting dry microstructures. Arrays of individual dots with base diameters of ~233–241 µm were obtained. Ring-shaped dots with dot edges higher than the center, 2.2 and 0.9 µm respectively, were obtained when a one-to-four diluted ink was used. With a less diluted ink (one-to-two diluted, the microstructure became more uniform with an average height of 3.0 µm, but the ink-jet printability was more difficult. Reactivity of the ink-jet deposited microstructures following drying and rehydration was studied in a non-growth medium by oxidation of 50 g/L D-sorbitol to L-sorbose, and a high dot volumetric reaction rate was measured (~435 g·L−1·h−1. These results indicate that latex ink microstructures generated by ink-jet printing may hold considerable potential for 3D fabrication of high surface-to-volume ratio biocoatings for use as microbial biosensors with the aim of coating microbes as reactive biosensors on electronic devices and circuit chips.

  3. Intravenous superoxide dismutase as a protective agent to prevent impairment of lung function induced by high tidal volume ventilation.

    Science.gov (United States)

    Wu, Nan-Chun; Liao, Fan-Ting; Cheng, Hao-Min; Sung, Shih-Hsien; Yang, Yu-Chun; Wang, Jiun-Jr

    2017-07-26

    Positive-pressure mechanical ventilation is essential in assisting patients with respiratory failure in the intensive care unit and facilitating oxygenation in the operating room. However, it was also recognized as a primary factor leading to hospital-acquired pulmonary dysfunction, in which pulmonary oxidative stress and lung inflammation had been known to play important roles. Cu/Zn superoxide dismutase (SOD) is an important antioxidant, and possesses anti-inflammatory capacity. In this study, we aimed to study the efficacy of Cu/Zn SOD, administered intravenously during high tidal volume (HTV) ventilation, to prevent impairment of lung function. Thirty-eight male Sprague-Dawley rats were divided into 3 groups: 5 h ventilation with (A) low tidal volume (LTV; 8 mL/kg; n = 10), (B) high tidal volume (HTV; 18 mL/kg; n = 14), or (C) HTV and intravenous treatment of Cu/Zn SOD at a dose of 1000 U/kg/h (HTV + SOD; n = 14). Lung function was evaluated both at baseline and after 5-h ventilation. Lung injury was assessed by histological examination, lung water and protein contents in the bronchoalveolar lavage fluid (BALF). Pulmonary oxidative stress was examined by concentrations of methylguanidine (MG) and malondialdehyde (MDA) in BALF, and antioxidative activity by protein expression of glutathione peroxidase-1 (GPx-1) in the lung. Severity of lung inflammation was evaluated by white blood cell and differential count in BALF, and protein expression of inducible nitric oxide synthase (iNOS), intercellular adhesion molecule-1 (ICAM-1), tumor necrosis factor-α (TNF-α), matrix metalloproteinase-9 (MMP-9), and mRNA expression of nuclear factor-κB (NF-κB) in the lung. We also examined protein expression of surfactant protein (SP)-A and D and we measured hourly changes in serum nitric oxide (NO) level. Five hours of LTV ventilation did not induce a major change in lung function, whereas 5 h of HTV ventilation induced apparent combined restrictive and

  4. To what extent do long-duration high-volume dam releases influence river–aquifer interactions? A case study in New South Wales, Australia

    KAUST Repository

    Graham, Peter W.

    2014-11-20

    Long-duration high-volume dam releases are unique anthropogenic events with no naturally occurring equivalents. The impact from such dam releases on a downstream Quaternary alluvial aquifer in New South Wales, Australia, is assessed. It is observed that long-duration (>26 days), high-volume dam releases (>8,000 ML/day average) result in significant variations in river–aquifer interactions. These variations include a flux from the river to the aquifer up to 6.3 m3/day per metre of bank (at distances of up to 330 m from the river bank), increased extent and volume of recharge/bank storage, and a long-term (>100 days) reversal of river–aquifer fluxes. In contrast, during lower-volume events (<2,000 ML/day average) the flux was directed from the aquifer to the river at rates of up to 1.6 m3/day per metre of bank. A groundwater-head prediction model was constructed and river–aquifer fluxes were calculated; however, predicted fluxes from this method showed poor correlation to fluxes calculated using actual groundwater heads. Long-duration high-volume dam releases have the potential to skew estimates of long-term aquifer resources and detrimentally alter the chemical and physical properties of phreatic aquifers flanking the river. The findings have ramifications for improved integrated management of dam systems and downstream aquifers.

  5. To what extent do long-duration high-volume dam releases influence river-aquifer interactions? A case study in New South Wales, Australia

    Science.gov (United States)

    Graham, P. W.; Andersen, M. S.; McCabe, M. F.; Ajami, H.; Baker, A.; Acworth, I.

    2015-03-01

    Long-duration high-volume dam releases are unique anthropogenic events with no naturally occurring equivalents. The impact from such dam releases on a downstream Quaternary alluvial aquifer in New South Wales, Australia, is assessed. It is observed that long-duration (>26 days), high-volume dam releases (>8,000 ML/day average) result in significant variations in river-aquifer interactions. These variations include a flux from the river to the aquifer up to 6.3 m3/day per metre of bank (at distances of up to 330 m from the river bank), increased extent and volume of recharge/bank storage, and a long-term (>100 days) reversal of river-aquifer fluxes. In contrast, during lower-volume events (bank. A groundwater-head prediction model was constructed and river-aquifer fluxes were calculated; however, predicted fluxes from this method showed poor correlation to fluxes calculated using actual groundwater heads. Long-duration high-volume dam releases have the potential to skew estimates of long-term aquifer resources and detrimentally alter the chemical and physical properties of phreatic aquifers flanking the river. The findings have ramifications for improved integrated management of dam systems and downstream aquifers.

  6. The local free volume and its correlation with the structural, chemical and dynamic properties of branched polymers, polymer electrolytes, highly oriented polyethylene fibres and other polymers

    International Nuclear Information System (INIS)

    Bamford, David

    2002-01-01

    frequently observed levelling off of the expansion of the hole volume at high temperatures is proposed in terms of increased thermal motions of the polymer chain segments on a time scale comparable to the o-Ps lifetime. The ionic conductivity of all the samples was found to follow both the Cohen-Turnbull and Vogel Tamman Fulcher theories over changes in the conductivity of several orders of magnitude demonstrating a direct link between the average free volume hole size and the ionic conductivity. Surprisingly, no clear differences were observed between the single ion and mixed ion conductors, showing the conduction mechanism to be independent of the specific interactions between the ions and the polymer chains. At temperatures near or below the glass transition, a change in the ion transport mechanism from a random redistribution of free volume in the rubbery phase to a thermally activated hopping in the glassy phase is observed. The anisotropic 'free volume hole' shape in highly oriented polyethylene fibres is studied using 2-Dimensional Angular Correlation of Annihilation Radiation spectroscopy and a new method of analysing the data is proposed. The average shape of these holes is determined and bears a remarkable similarity to the expected shape of chain fold defects in the crystalline phase. Finally, the potential use of Doppler Broadening of Annihilation Radiation DBAR spectroscopy as a probe of the chemical surroundings of free volume holes in polymers is assessed. Several series of fluorinated polymers are studied using PALS and DBAR spectroscopy and a linear decrease in the S-parameter of the annihilation peak is observed with increasing fluorine content. Using a new coincidence DBAR spectrometer it was found that the presence of oxygen, fluorine or chlorine in polymers could be identified from subtle but characteristic changes in the shape of the annihilation peak. (author)

  7. Preventive maintenance basis: Volume 10 -- High voltage electric motors (5 kV and greater). Final report

    International Nuclear Information System (INIS)

    Worledge, D.; Hinchcliffe, G.

    1997-07-01

    US nuclear plants are implementing preventive maintenance (PM) tasks with little documented basis beyond fundamental vendor information to support the tasks or their intervals. The Preventive Maintenance Basis project provides utilities with the technical basis for PM tasks and task intervals associated with 40 specific components such as valves, electric motors, pumps, and HVAC equipment. This report provides an overview of the PM Basis project and describes use of the PM Basis database. Volume 10 of the report provides a program of PM tasks suitable for application to high voltage (5kV and greater) electric motors in nuclear power plants. The PM tasks that are recommended provide a cost-effective way to intercept the causes and mechanisms that lead to degradation and failure. They can be used, in conjunction with material from other sources, to develop a complete PM program or to improve an existing program. Users of this information will be utility managers, supervisors, craft technicians, and training instructors responsible for developing, optimizing, or fine-tuning PM programs. Reactor Coolant Pumps motors (RCP's) are not excluded from this report in so far as good PM practices for motors of the appropriate class are concerned. However, the special auxiliary equipment normally associated with RCP's has not been included. Consequently, this report does not provide a complete PM program for RCP's. Industry and vendor programs for RCP's should be consulted for complete definition of RCP motor PM programs

  8. Effect of Copolymer Latexes on Physicomechanical Properties of Mortar Containing High Volume Fly Ash as a Replacement Material of Cement

    Directory of Open Access Journals (Sweden)

    El-Sayed Negim

    2014-01-01

    Full Text Available This paper investigates the physicomechanical properties of mortar containing high volume of fly ash (FA as partial replacement of cement in presence of copolymer latexes. Portland cement (PC was partially replaced with 0, 10, 20, 30 50, and 60% FA. Copolymer latexes were used based on 2-hydroxyethyl acrylate (2-HEA and 2-hydroxymethylacrylate (2-HEMA. Testing included workability, setting time, absorption, chemically combined water content, compressive strength, and scanning electron microscopy (SEM. The addition of FA to mortar as replacement of PC affected the physicomechanical properties of mortar. As the content of FA in the concrete increased, the setting times (initial and final were elongated. The results obtained at 28 days of curing indicate that the maximum properties of mortar occur at around 30% FA. Beyond 30% FA the properties of mortar reduce and at 60% FA the properties of mortar are lower than those of the reference mortar without FA. However, the addition of polymer latexes into mortar containing FA improved most of the physicomechanical properties of mortar at all curing times. Compressive strength, combined water, and workability of mortar containing FA premixed with latexes are higher than those of mortar containing FA without latexes.

  9. Effect of copolymer latexes on physicomechanical properties of mortar containing high volume fly ash as a replacement material of cement.

    Science.gov (United States)

    Negim, El-Sayed; Kozhamzharova, Latipa; Gulzhakhan, Yeligbayeva; Khatib, Jamal; Bekbayeva, Lyazzat; Williams, Craig

    2014-01-01

    This paper investigates the physicomechanical properties of mortar containing high volume of fly ash (FA) as partial replacement of cement in presence of copolymer latexes. Portland cement (PC) was partially replaced with 0, 10, 20, 30 50, and 60% FA. Copolymer latexes were used based on 2-hydroxyethyl acrylate (2-HEA) and 2-hydroxymethylacrylate (2-HEMA). Testing included workability, setting time, absorption, chemically combined water content, compressive strength, and scanning electron microscopy (SEM). The addition of FA to mortar as replacement of PC affected the physicomechanical properties of mortar. As the content of FA in the concrete increased, the setting times (initial and final) were elongated. The results obtained at 28 days of curing indicate that the maximum properties of mortar occur at around 30% FA. Beyond 30% FA the properties of mortar reduce and at 60% FA the properties of mortar are lower than those of the reference mortar without FA. However, the addition of polymer latexes into mortar containing FA improved most of the physicomechanical properties of mortar at all curing times. Compressive strength, combined water, and workability of mortar containing FA premixed with latexes are higher than those of mortar containing FA without latexes.

  10. APS 6BM-B Large Volume High Pressure Beamline: A Workhorse for Rock and Mineral Physics

    Science.gov (United States)

    Chen, H.; Whitaker, M. L.; Baldwin, K. J.; Huebsch, W. R.; Vaughan, M. T.; Weidner, D. J.

    2017-12-01

    With the inheritance of decades of technical innovations at the NSLS X17B2 Beamline, APS 6BM-B Beamline was established in 2015 and is a dedicated beamline for synchrotron-based large volume high pressure research in earth sciences, especially rock and mineral physics. Currently a 250-ton hydraulic press equipped with a D-DIA module is installed and a Rotational Drickamer Apparatus from Yale University is hosted every cycle, covering a pressure range from crust to lower mantle. 6BM-B operates in white beam mode with an effective energy range of 20-100 keV. Energy dispersive X-ray diffraction data is collected using a 10-element solid state Ge array detector arranged in a circular geometry to allow for the real time assessment of stress. Direct radiographic imaging using Prosillica CCD camera and scintillating YAG crystals yields sample strain and strain rate. In addition to applications in phase transitions, equation of states measurements, sound velocity measurements, this setup is ideal for studies of steady state and dynamic deformation process. In this presentation, technical features and strengths of 6BM-B will be discussed. Most recent progress and science highlights of our user community will be showcased.

  11. Effects of high-volume plasmapheresis on ammonia, urea, and amino acids in patients with acute liver failure.

    Science.gov (United States)

    Clemmesen, J O; Kondrup, J; Nielsen, L B; Larsen, F S; Ott, P

    2001-04-01

    In acute liver failure (ALF), urea production is severely impaired, and detoxification of ammonia by glutamine synthesis plays an important protective role. The aim of this study was to examine the effects of therapeutic high-volume plasmapheresis (HVP) on arterial concentrations and splanchnic exchange rates of ammonia, urea, and amino acids-in particular, glutamine. A quantity of 8 L of plasma was exchanged over the course of 7 h in 11 patients with ALF after development of hepatic encephalopathy grade III-IV. Splanchnic exchange rates of ammonia, urea, and amino acids were measured by use of liver vein catheterization. HVP removed ammonia and glutamine at a rate of 1 micromol/min and 27 micromol/min, respectively. Arterial ammonia decreased from 160 +/- 65 to 114 +/- 50 micromol/L (p HVP) were as follows: for ammonia, -93 +/- 101 versus -70 +/- 80 micromol/min (NS); urea-nitrogen, 0.08 +/- 1.64 versus -0.31 +/- 0.45 mmol/min (NS); alanine, -73 +/- 151 versus 12 +/- 83 micromol/min (p HVP in patients with ALF. The data suggest that this effect of HVP could be explained by increased hepatic urea synthesis and possibly by increased glutamine synthesis in muscle tissue.

  12. Development of large-volume, high-resolution tracking detectors based on capillaries filled with liquid scintillator

    International Nuclear Information System (INIS)

    Buontempo, S.; Fabre, J.P.; Frenkel, A.; Gregoire, G.; Hoepfner, K.; Konijn, J.; Kozarenko, E.; Kreslo, I.; Kushnirenko, A.; Martellotti, G.; Michel, L.; Mondardini, M.R.; Penso, G.; Siegmund, W.P.; Strack, R.; Tyukov, V.; Vasilchenko, V.; Vilain, P.; Wilquet, G.; Winter, K.; Wong, H.; Zymin, K.

    1995-01-01

    Searches for the decay of short-lived particles require real time, high-resolution tracking in active targets, which in the case of neutrino physics should be of large volume. The possibility of achieving this by using glass capillaries filled with organic liquid scintillator is being investigated in the framework of the CHORUS experiment at CERN. In this paper, after outlining the application foreseen, advances in the tracking technique are discussed and results from tests are reported. An active target of dimensions 180x2x2 cm 3 has been assembled from capillaries with 20 μm diameter pores. The readout scheme currently in operation allows the reading of similar 5x10 5 channels using a single chain of image intensifiers having a resolution of σ similar 20 μm. Following the development of new liquid scintillators and purification methods an attenuation length of similar 3 m has been obtained. This translates into a hit density of 3.5 per mm for a minimum-ionizing particle that crosses the active target at a distance of 1 m from the readout end. (orig.)

  13. THE SPITZER EXTRAGALACTIC REPRESENTATIVE VOLUME SURVEY: THE ENVIRONMENTS OF HIGH-z SDSS QUASI-STELLAR OBJECTS

    International Nuclear Information System (INIS)

    Falder, J. T.; Stevens, J. A.; Jarvis, Matt J.; Bonfield, D. G.; Lacy, M.; Farrah, D.; Oliver, S.; Surace, J.; Mauduit, J.-C.; Vaccari, M.; Marchetti, L.; Gonzalez-Solares, E.; Afonso, J.; Cava, A.; Seymour, N.

    2011-01-01

    This paper presents a study of the environments of SDSS quasi-stellar objects (QSOs) in the Spitzer Extragalactic Representative Volume Survey (SERVS). We concentrate on the high-redshift QSOs as these have not been studied in large numbers with data of this depth before. We use the IRAC 3.6-4.5 μm color of objects and ancillary r-band data to filter out as much foreground contamination as possible. This technique allows us to find a significant (>4σ) overdensity of galaxies around QSOs in a redshift bin centered on z ∼ 2.0 and an (>2σ) overdensity of galaxies around QSOs in a redshift bin centered on z ∼ 3.3. We compare our findings to the predictions of a semi-analytic galaxy formation model, based on the ΛCDM MILLENNIUM simulation, and find for both redshift bins that the model predictions match well the source density we have measured from the SERVS data.

  14. High Patient Satisfaction of a Hyaluronic Acid Filler Producing Enduring Full-Facial Volume Restoration: An 18-Month Open Multicenter Study.

    Science.gov (United States)

    Talarico, Sergio; Meski, Ana P; Buratini, Laura; Manela-Azulay, Mônica; Simpson, Helen; Sidou, Farzaneh; Kerrouche, Nabil

    2015-12-01

    Volume restoration is an essential part of facial rejuvenation. To assess long-term full-facial volume restoration using HAEL Volume Lidocaine hyaluronic acid filler. An 18-month open study in 60 subjects with at least Grade 2 on the 4-point volume loss scale (VLS) for full face and at least 2 indications affected among chin, temporal areas, jawline, cheeks, cheekbones, and nasolabial folds (NLF). Performance was assessed by VLS, Lemperle rating scale (LRS), investigator Global Aesthetic Improvement Scale (GAIS), and 3-dimensional (3D) imaging. Most subjects (71.6%) had 3 or 4 indications injected, most commonly cheekbones (96.7%) and NLF (93.3%). At 18 months, at least a 1-grade improvement in VLS was observed for full face (68.3% of subjects), chin (77.8%), temporal areas (73.7%), cheeks (66.6%), cheekbones (58.6%), jawline (43.1%), and NLF (71.4%; LRS). For all indications, more than 60% of the volume gained at 3 weeks was sustained at 18 months based on 3D digital imaging. At 18 months, 95.0% of subjects had improved full-face GAIS and all subjects were satisfied with their aesthetic outcome. One subject (1.6%) had treatment-related adverse events. Full-facial volume restoration was well sustained over 18 months with high patient satisfaction and good tolerability.

  15. Pituitary gland volume in patients with schizophrenia, subjects at ultra high-risk of developing psychosis and healthy controls: a systematic review and meta-analysis.

    Science.gov (United States)

    Nordholm, Dorte; Krogh, Jesper; Mondelli, Valeria; Dazzan, Paola; Pariante, Carmine; Nordentoft, Merete

    2013-11-01

    A larger pituitary size is thought to reflect a greater activation of the hypothalamic-pituitary-adrenal (HPA) axis, which may be related to an increase in the number and size of corticotroph cells. Some studies, but not all, indicate that pituitary volume increases before or at the onset of psychosis. There is a need for at critical appraisal of the literature on this topic accompanied by a meta-analytical evaluation of the data. We included studies comparing the volume of the pituitary gland in healthy controls and patients with schizophrenia, first episode of psychosis (FEP), schizotypal disorder or ultra high-risk (UHR) subjects. We defined three groups of subjects for the analyses: healthy controls; UHR and schizotypal patients; and patients diagnosed with first episode of psychosis, schizophrenia or schizoaffective disorder. Ten studies were included in the meta-analysis. We found a trend of a larger pituitary volume in both UHR subject who had transition to psychosis (p=0.05) and in FEP subjects (p=0.09) compared to healthy controls. There was no difference in pituitary volume between patients with schizophrenia combined with FEP versus healthy controls (p=0.52) or between UHR (with and without transition) and healthy controls (p=0.24). In a regression analysis, we demonstrated that the number of subjects receiving antipsychotics and pituitary volume were positively correlated. As previously reported in other samples, gender also had an impact on pituitary volume with females presenting with a larger mean volume. Results from this meta-analysis suggest that the pituitary gland could be increasing before the onset of psychosis. Both gender and use of antipsychotics have a major impact on the pituitary volume. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training

    Science.gov (United States)

    Stöggl, Thomas L.; Björklund, Glenn

    2017-01-01

    The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR) in well-trained endurance athletes. Methods: Thirty-six male (n = 33) and female (n = 3) runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO2peak): 61.9 ± 8.0 mL·kg−1·min−1] were randomly assigned to one of three groups (blocked high intensity interval training HIIT; polarized training POL; high volume low intensity oriented control group CG/HVLIT applying no HIIT). A maximal anaerobic running/cycling test (MART/MACT) was performed prior to and following a 9-week training period. Results: Only the HIIT group achieved improvements in peak power/velocity (+6.4%, P 0.05). Acute HRR was improved in HIIT (11.2%, P = 0.002) and POL (7.9%, P = 0.023) with no change in the HVLIT oriented control group. Conclusion: Only a training regime that includes a significant amount of HIIT improves the neuromuscular status, anaerobic power and the acute HRR in well-trained endurance athletes. A training regime that followed more a low and moderate intensity oriented model (CG/HVLIT) had no effect on any performance or HRR outcomes. PMID:28824457

  17. Successful well test application of portable multi-phase flow meter for high gas-volume and high water-cut wells in east Kalimantan, Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Kaura, Jiten D.; Finley, D.B. [PT Halliburton Indonesia, Jakarta (Indonesia); Sudradjat, Wangsa; Riyanto, Latief [Tota E and P Indonesie, Jakarta (Indonesia); Halverson, Martin [FlowSys AS, Bergen (Norway)

    2004-07-01

    Recently, testing was needed on production wells in East Kalimantan. The wells were in a mature field, and productivity from the wells field featured high water cut (WC) and extremely high gas-volume fractions (GVF). The WC and GVF ranged from 80 to 100% and 90 to 100%, respectively. Moreover, most of the wells are low productivity so they are very sensitive to back-pressure. The high WC, high GVF and low-productivity from these wells in this area present an extreme challenge for accurate production measurement. Barges are commonly used to perform well services in the swamp area of this marginal field, and production allocations from wells in this difficult area were previously monitored and measured with conventional well-test equipment on-board a well testing barge. The well test equipment traditionally used requires a large footprint, and the associated flaring presents an environmental situation in this sensitive swamp area. Hence, the MPFM solution was chosen. To better meet the challenges presented by the testing conditions, a portable multiphase flow meter (MPFM) was chosen to perform the testing from the well-testing barge. For comparative purposes, the MPFM was installed on the barge immediately upstream of the well testing equipment. Initial measurements with the MPFM yielded results that were {+-} 30% of the test separator reading. A slight modification was introduced to the MPFM system in the form of a gas knock-out (GKO) vessel. Subsequent measurements with the modified MPFM system yielded readings that were {+-}10% of the test separator reading. (author)

  18. Angle β of greater than 80° at the start of spirometry may identify high-quality flow volume curves.

    Science.gov (United States)

    Lian, Ningfang; Li, Li; Ren, Weiying; Jiang, Zhilong; Zhu, Lei

    2017-04-01

    The American Thoracic Society (ATS) and European Respiratory Society (ERS) emphasize a satisfactory start in maximal expiratory flow-volume (MEFV) curves and highlight subjective parameters: performance without hesitation and expiration with maximum force. We described a new parameter, angle β for characterization of the start to the MEFV curve. Subjects completed the MEFV curve at least three times and at least two curves met ATS/ERS quality. Subjects were divided into normal, restrictive and obstructive groups according to pulmonary function test results. The tangent line was drawn at the start of the MEFV curve's ascending limb to the x-axis and the angle β between the tangent line and x-axis was obtained. The relationships between tangent of β, pulmonary function parameters (PFPs) and anthropometric data were assessed. The MEFV curves with insufficient explosion at the start were considered as poor-quality MEFV curves. In 998 subjects with high-quality spirometry, although PFP varied in relation to the three aspects: the angle β and its tangent were similar (P > 0.05), the tangent of β did not correlate with PFP or anthropometric measurements (P > 0.05) and the lower limit of normal (LLN) of the angle β was 80° in the group with high-quality spirometry (P < 0.05). Angle β derived from poor-quality MEFV curves was smaller than that from good quality one (P < 0.05). Angle β may function as a parameter to assess the expiratory efforts, which can be used to assess the quality of the MEFV curve start. © 2016 Asian Pacific Society of Respirology.

  19. A study on the effect of nano silica on compressive strength of high volume fly ash mortars and concretes

    International Nuclear Information System (INIS)

    Shaikh, F.U.A.; Supit, S.W.M.; Sarker, P.K.

    2014-01-01

    Highlights: • The addition of NS compensates low early age compressive strength of HVFA system. • NS also contributes to later age compressive strength gain of HVFA system. • The XRD results confirm the reduction of CH in HVFA paste due to addition of NS. - Abstract: This paper presents the effect of nano silica (NS) on the compressive strength of mortars and concretes containing different high volume fly ash (HVFA) contents ranging from 40% to 70% (by weight) as partial replacement of cement. The compressive strength of mortars is measured at 7 and 28 days and that for concretes is measured at 3, 7, 28, 56 and 90 days. The effects of NS in microstructure development and pozzolanic reaction of pastes containing above HVFA contents are also studied through backscattered electron (BSE) image and X-ray diffraction (XRD) analysis. Results show that among different NS contents ranging from 1% to 6%, cement mortar containing 2% NS exhibited highest 7 and 28 days compressive strength. This NS content (2%) is then added to the HVFA mortars and concretes and the results show that the addition of 2% NS improved the early age (7 days) compressive strength of mortars containing 40% and 50% fly ash by 5% and 7%, respectively. However, this improvement is not observed at high fly ash contents beyond 50%. On the other hand, all HVFA mortars exhibited improvement in 28 days compressive strength due to addition of 2% NS and the most significant improvement is noticed in mortars containing more than 50% fly ash. In HVFA concretes, the improvement of early age (3 days) compressive strength is also noticed due to addition of 2% NS. The BSE and XRD analysis results also support the above findings

  20. Feasibility and safety of cavity-directed stereotactic radiosurgery for brain metastases at a high-volume medical center

    Directory of Open Access Journals (Sweden)

    Paul Rava, MD PhD

    2016-07-01

    Conclusions: Excellent local control is achievable with cavity-directed SRS in well-selected patients, particularly for lesions with diameter <3 cm and resection cavity volumes <14 mL. Long-term survival is possible for select patients.

  1. High-surgical-volume hospitals associated with better quality and lower cost of kidney transplantation in Taiwan

    Directory of Open Access Journals (Sweden)

    Shu-Yun Tsao

    2011-01-01

    Conclusion: Seventy-seven percent of kidney transplant surgeries were concentrated at six hospitals in Taiwan. There were significant differences in quality and cost between HSVHs and LSVHs. We suggest adopting volume-based strategies for nonurgent kidney transplants.

  2. Measuring the volume of frontal lobe in healthy Chinese adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Yin Lu; Liu Peifang; Ye Zhaoxiang; Chen Nan; Wang Xing; Li Kuncheng; Zhuo Yan; Chen Lin

    2010-01-01

    Objective: To explore the normal range of the volume of frontal lobe in Chinese adults of the Han nationality and provide morphological data for the construction of database for Chinese Standard Brain. Methods: This is a clinical multi-center study. Two hundred Chinese healthy volunteers (age range =18 to 70) recruited from 16 hospitals were divided into 5 groups, i.e., age range from 18 to 30, age range from 31 to 40, age range from 41 to 50, age range from 51 to 60, and age range from 61 to 70. Each group contained 20 males and 20 females. All of the volunteers were scanned by MR using T 1 weighted three- dimensional magnetization prepared rapid acquisition gradient echo sequence. We used the manual method to trace the region of interest and measured the left and right frontal lobe volumes separately. All the data were analyzed with SPSS (version 13.0). The sex differences in the frontal lobe volumes were analyzed by independent-samples t test, and the side differences were analyzed by paired-samples t test. Correlation and regression analysis was used between the age and the frontal lobe volumes. Results: In 200 healthy Chinese Han volunteers, the total frontal lobe volumes was (563±73) cm 3 . For male, the volumes of the left and the right frontal lobe were (288±42) cm 3 and (292±41) cm 3 , respectively. The volumes of the left and right frontal lobe in 100 women were (273±30)cm 3 and (274±30) cm 3 respectively. The differences of sex (t=3.334, P 0.05). There were negative correlations between the frontal lobe volumes and age in men and women (r=-0.586, -0.498, P< 0.01). Conclusions: The total frontal lobe volume of men was larger than that of women. The volume of the right frontal lobe was larger than the left frontal lobe in men, and the asymmetries didn't exist in women. The total frontal lobe volumes were both shrinking with age in men and women, which was more rapid in men than in women. (authors)

  3. Estimation of mean tree stand volume using high-resolution aerial RGB imagery and digital surface model, obtained from sUAV and Trestima mobile application

    Directory of Open Access Journals (Sweden)

    G. K. Rybakov

    2017-06-01

    Full Text Available This study considers a remote sensing technique for mean volume estimation based on a very high-resolution (VHR aerial RGB imagery obtained using a small-sized unmanned aerial vehicle (sUAV and a high-resolution photogrammetric digital surface model (DSM as well as an innovative technology for field measurements (Trestima. The study area covers approx. 220 ha of forestland in Finland. The work concerns the entire process from remote sensing and field data acquisition to statistical analysis and forest volume wall-to-wall mapping. The study showed that the VHR aerial imagery and the high-resolution DSM produced based on the application of the sUAV have good prospects for forest inventory. For the sUAV based estimation of forest variables such as Height, Basal Area and mean Volume, Root Mean Square Error constituted 6.6 %, 22.6 % and 26.7 %, respectively. Application of Trestima for estimation of the mean volume of the standing forest showed minor difference over the existing Forest Management Plan at all the selected forest compartments. Simultaneously, the results of the study confirmed that the technologies and the tools applied at this work could be a reliable and potentially cost-effective means of forest data acquisition with high potential of operational use.

  4. Design and Development of Virtual Reality Simulation for Teaching High-Risk Low-Volume Problem-Prone Office-Based Medical Emergencies

    Science.gov (United States)

    Lemheney, Alexander J.

    2014-01-01

    Physicians' offices are not the usual place where emergencies occur; thus how staff remains prepared and current regarding medical emergencies presents an ongoing challenge for private practitioners. The very nature of low-volume, high-risk, and problem-prone medical emergencies is that they occur with such infrequency it is difficult for staff to…

  5. SOAC - State-of-the-Art Car Engineering Tests at Department of Transportation High Speed Ground Test Center : Volume 2. Performance Tests.

    Science.gov (United States)

    1975-01-01

    The six-volume report presents the technical methodology, data samples, and results of tests conducted on the SOAC on the Rail Transit Test Track at the High Speed Ground Test Center in Pueblo, Colorado during the period April to July 1973. The Test ...

  6. High School and Beyond. 1980 Senior Coort. Third-Follow-Up (1986). Data File User's Manual. Volume II: Survey Instruments. Contractor Report.

    Science.gov (United States)

    Sebring, Penny; And Others

    Survey instruments used in the collection of data for the High School and Beyond base year (1980) through the third follow-up surveys (1986) are provided as Volume II of a user's manual for the senior cohort data file. The complete user's manual is designed to provide the extensive documentation necessary for using the cohort data files. Copies of…

  7. The Complete Local Volume Groups Sample - I. Sample selection and X-ray properties of the high-richness subsample

    Science.gov (United States)

    O'Sullivan, Ewan; Ponman, Trevor J.; Kolokythas, Konstantinos; Raychaudhury, Somak; Babul, Arif; Vrtilek, Jan M.; David, Laurence P.; Giacintucci, Simona; Gitti, Myriam; Haines, Chris P.

    2017-12-01

    We present the Complete Local-Volume Groups Sample (CLoGS), a statistically complete optically selected sample of 53 groups within 80 Mpc. Our goal is to combine X-ray, radio and optical data to investigate the relationship between member galaxies, their active nuclei and the hot intra-group medium (IGM). We describe sample selection, define a 26-group high-richness subsample of groups containing at least four optically bright (log LB ≥ 10.2 LB⊙) galaxies, and report the results of XMM-Newton and Chandra observations of these systems. We find that 14 of the 26 groups are X-ray bright, possessing a group-scale IGM extending at least 65 kpc and with luminosity >1041 erg s-1, while a further three groups host smaller galaxy-scale gas haloes. The X-ray bright groups have masses in the range M500 ≃ 0.5-5 × 1013 M⊙, based on system temperatures of 0.4-1.4 keV, and X-ray luminosities in the range 2-200 × 1041 erg s-1. We find that ∼53-65 per cent of the X-ray bright groups have cool cores, a somewhat lower fraction than found by previous archival surveys. Approximately 30 per cent of the X-ray bright groups show evidence of recent dynamical interactions (mergers or sloshing), and ∼35 per cent of their dominant early-type galaxies host active galactic nuclei with radio jets. We find no groups with unusually high central entropies, as predicted by some simulations, and confirm that CLoGS is in principle capable of detecting such systems. We identify three previously unrecognized groups, and find that they are either faint (LX, R500 < 1042 erg s-1) with no concentrated cool core, or highly disturbed. This leads us to suggest that ∼20 per cent of X-ray bright groups in the local universe may still be unidentified.

  8. Hepatic blood flow and splanchnic oxygen consumption in patients with liver failure. Effect of high-volume plasmapheresis.

    Science.gov (United States)

    Clemmesen, J O; Gerbes, A L; Gülberg, V; Hansen, B A; Larsen, F S; Skak, C; Tygstrup, N; Ott, P

    1999-02-01

    Liver failure represents a major therapeutic challenge, and yet basic pathophysiological questions about hepatic perfusion and oxygenation in this condition have been poorly investigated. In this study, hepatic blood flow (HBF) and splanchnic oxygen delivery (DO2, sp) and oxygen consumption (VO2,sp) were assessed in patients with liver failure defined as hepatic encephalopathy grade II or more. Measurements were repeated after high-volume plasmapheresis (HVP) with exchange of 8 to 10 L of plasma. HBF was estimated by use of constant infusion of D-sorbitol and calculated according to Fick's principle from peripheral artery and hepatic vein concentrations. In 14 patients with acute liver failure (ALF), HBF (1.78 +/- 0.78 L/min) and VO2,sp (3.9 +/- 0.9 mmol/min) were higher than in 11 patients without liver disease (1.07 +/- 0.19 L/min, P HVP, HBF increased from 1.67 +/- 0.72 to 2.07 +/- 1.11 L/min (n=11) in ALF, and from 1.89 +/- 1.32 to 2.34 +/- 1.54 L/min (n=7) in AOCLD, P HVP. Blood flow was redirected to the liver as the systemic vascular resistance index increased (1,587 +/- 650 vs. 2, 020 +/- 806 Dyne. s. cm-5. m2, P HVP, but as cardiac output increased from 9.1 +/- 2.8 to 10.1 +/- 2.9 L/min (P HVP (n=18), DO2,sp increased by 15% (P HVP. Changes of ET-1 were positively correlated with changes in HBF (P HVP (P HVP did not correlate. Our data suggest that liver failure is associated with increased HBF and VO2, sp. HVP further increased HBF and DO2,sp but VO2,sp was unchanged, indicating that splanchnic hypoxia was not present.

  9. Fully digital data processing during cardiovascular implantable electronic device follow-up in a high-volume tertiary center.

    Science.gov (United States)

    Staudacher, Ingo; Nalpathamkalam, Asha Roy; Uhlmann, Lorenz; Illg, Claudius; Seehausen, Sebastian; Akhavanpoor, Mohammadreza; Buchauer, Anke; Geis, Nicolas; Lugenbiel, Patrick; Schweizer, Patrick A; Xynogalos, Panagiotis; Zylla, Maura M; Scholz, Eberhard; Zitron, Edgar; Katus, Hugo A; Thomas, Dierk

    2017-10-11

    Increasing numbers of patients with cardiovascular implantable electronic devices (CIEDs) and limited follow-up capacities highlight unmet challenges in clinical electrophysiology. Integrated software (MediConnect ® ) enabling fully digital processing of device interrogation data has been commercially developed to facilitate follow-up visits. We sought to assess feasibility of fully digital data processing (FDDP) during ambulatory device follow-up in a high-volume tertiary hospital to provide guidance for future users of FDDP software. A total of 391 patients (mean age, 70 years) presenting to the outpatient department for routine device follow-up were analyzed (pacemaker, 44%; implantable cardioverter defibrillator, 39%; cardiac resynchronization therapy device, 16%). Quality of data transfer and follow-up duration were compared between digital (n = 265) and manual processing of device data (n = 126). Digital data import was successful, complete and correct in 82% of cases when early software versions were used. When using the most recent software version the rate of successful digital data import increased to 100%. Software-based import of interrogation data was complete and without failure in 97% of cases. The mean duration of a follow-up visit did not differ between the two groups (digital 18.7 min vs. manual data transfer 18.2 min). FDDP software was successfully implemented into the ambulatory follow-up of patients with implanted pacemakers and defibrillators. Digital data import into electronic patient management software was feasible and supported the physician's workflow. The total duration of follow-up visits comprising technical device interrogation and clinical actions was not affected in the present tertiary center outpatient cohort.

  10. Preseason Workload Volume and High-Risk Periods for Noncontact Injury Across Multiple Australian Football League Seasons.

    Science.gov (United States)

    Colby, Marcus J; Dawson, Brian; Heasman, Jarryd; Rogalski, Brent; Rosenberg, Michael; Lester, Leanne; Peeling, Peter

    2017-07-01

    Colby, MJ, Dawson, B, Heasman, J, Rogalski, B, Rosenberg, M, Lester, L, and Peeling, P. Preseason workload volume and high-risk periods for noncontact injury across multiple Australian Football League seasons. J Strength Cond Res 31(7): 1821-1829, 2017-The purpose of this study was to assess the association between preseason workloads and noncontact injury risk in Australian football players. Individual player injury data were recorded over 4 full seasons (2012-15) from one professional club. Noncontact injury incidence (per 1,000 "on legs" field training and game hours) was compared across the preseason, precompetition, and in-season phases to determine relative noncontact injury risk. Preseason workloads (global positioning system-derived total distance run and sprint distance) and individual (fixed) injury risk factors (age, previous injury history) were incorporated into the analysis. A generalized estimating equation with a binary logistic function modeled potential risk factors with noncontact injury for selected periods across the annual cycle. Odds ratios were calculated to determine the relative injury risk. The (preseason) precompetition phase (19.1 injuries per 1,000 hours) and (in-season) rounds 12-17 (16.0 injuries per 1,000 hours) resulted in the highest injury incidence. Low cumulative total distances in late preseason (<108 km) and precompetition (76-88 km) periods were associated with significantly (p ≤ 0.05) greater injury risk during the in-season phase. In conclusion, these results suggest players are at the greatest injury risk during the precompetition period, with low preseason cumulative workloads associated with increased in-season injury risk. Therefore, strength and conditioning staff should place particular emphasis on achieving at least moderate training loads during and leading into this phase, where competitive game play is first introduced.

  11. CONWIP versus POLCA: A comparative analysis in a high-mix, low-volume (HMLV) manufacturing environment

    Energy Technology Data Exchange (ETDEWEB)

    Frazee, T.; Standridge, C.

    2016-07-01

    Few studies comparing manufacturing control systems as they relate to high-mix, low-volume applications have been reported. This paper compares two strategies, constant work in process (CONWIP) and Paired-cell Overlapping Loops of Cards with Authorization (POLCA), for controlling work in process (WIP) in such a manufacturing environment. Characteristics of each control method are explained in regards to lead time impact and thus, why one may be advantageous over the other. An industrial system in the Photonics industry is studied. Discrete event simulation is used as the primary tool to compare performance of CONWIP and POLCA controls for the same WIP level with respect to lead time. Model verification and validation are accomplished by comparing historic data to simulation generated data including utilizations. Both deterministic and Poisson distributed order arrivals are considered. For the system considered in this case study, including order arrival patterns, a POLCA control can outperform a CONWIP parameter in terms of average lead time for a given level of WIP. At higher levels of WIP, the performance of POLCA and CONWIP is equivalent. The POLCA control helps limit WIP in specific áreas of the system where the CONWIP control only limits the overall WIP in the system. Thus, POLCA can generate acceptably low lead times at lower levels of WIP for conditions equivalent to the HMLV manufacturing systems studied. The study compliments and extends previous studies of CONWIP and POLCA performance to a HMLV manufacturing environment. It demonstrates the utility of discrete event simulation in that regard. It shows that proper inventory controls in bottleneck áreas of a system can reduce average lead time. (Author)

  12. Do Red Edge and Texture Attributes from High-Resolution Satellite Data Improve Wood Volume Estimation in a Semi-Arid Mountainous Region?

    DEFF Research Database (Denmark)

    Schumacher, Paul; Mislimshoeva, Bunafsha; Brenning, Alexander

    2016-01-01

    to overcome this issue. However, clear recommendations on the suitability of specific proxies to provide accurate biomass information in semi-arid to arid environments are still lacking. This study contributes to the understanding of using multispectral high-resolution satellite data (RapidEye), specifically...... red edge and texture attributes, to estimate wood volume in semi-arid ecosystems characterized by scarce vegetation. LASSO (Least Absolute Shrinkage and Selection Operator) and random forest were used as predictive models relating in situ-measured aboveground standing wood volume to satellite data...

  13. High-power linearly-polarized operation of a cladding-pumped Yb fibre laser using a volume Bragg grating for wavelength selection.

    Science.gov (United States)

    Jelger, P; Wang, P; Sahu, J K; Laurell, F; Clarkson, W A

    2008-06-23

    In this work a volume Bragg grating is used as a wavelength selective element in a high-power cladding-pumped Yb-doped silica fiber laser. The laser produced 138 W of linearly-polarized single-spatial-mode output at 1066 nm with a relatively narrow linewidth of 0.2 nm for approximately 202 W of launched pump power at 976 nm. The beam propagation factor (M(2)) for the output beam was determined to be 1.07. Thermal limitations of volume Bragg gratings are discussed in the context of power scaling for fiber lasers.

  14. Effect of tapering after a period of high-volume sprint interval training on running performance and muscular adaptations in moderately trained runners

    DEFF Research Database (Denmark)

    Skovgaard, Casper; Almquist, Nicki Winfield; Kvorning, Thue

    2018-01-01

    The effect of tapering following a period of high-volume sprint interval training (SIT) and a basic volume of aerobic training on performance and muscle adaptations in moderately trained runners was examined. Eleven (8 males, 3 females) runners (maximum oxygen uptake (VO2-max): 56.8±2.9 mL·min(-1...... running test at 90% of vVO2-max to exhaustion (RRT). In addition, a biopsy from m. vastus lateralis was obtained at rest. Performance during RRT was better (P... at 60% of vVO2-max was lower (P

  15. High-energy X-ray measurements of structural anisotropy and excess free volume in a homogenously deformed Zr-based metallic glass

    International Nuclear Information System (INIS)

    Ott, R.T.; Kramer, M.J.; Besser, M.F.; Sordelet, D.J.

    2006-01-01

    We have used high-energy X-ray scattering to measure the structural anisotropy and excess free volume in a homogeneously deformed Zr-based metallic glass alloy. The scattering results show that bond length anisotropy is present in the samples following isothermal tensile creep deformation. The average atomic bond length in the direction parallel to the tensile loading axis is larger than that in the direction normal to the loading axis. The magnitude of the bond length anisotropy is found to be dependent on the gradient of macroscopic plastic strain along the gauge length. Furthermore, the scattering results show that the excess free volume also increases with increasing macroscopic plastic strain. Results from differential scanning calorimetry analysis of free volume variations along the gauge length of the creep samples are consistent with results from the X-ray scattering experiments

  16. A method for volume determination of the orbit and its contents by high resolution axial tomography and quantitative digital image analysis.

    Science.gov (United States)

    Cooper, W C

    1985-01-01

    The various congenital and acquired conditions which alter orbital volume are reviewed. Previous investigative work to determine orbital capacity is summarized. Since these studies were confined to postmortem evaluations, the need for a technique to measure orbital volume in the living state is presented. A method for volume determination of the orbit and its contents by high-resolution axial tomography and quantitative digital image analysis is reported. This procedure has proven to be accurate (the discrepancy between direct and computed measurements ranged from 0.2% to 4%) and reproducible (greater than 98%). The application of this method to representative clinical problems is presented and discussed. The establishment of a diagnostic system versatile enough to expand the usefulness of computerized axial tomography and polytomography should add a new dimension to ophthalmic investigation and treatment.

  17. High Intensity High Volume Interval Training Improves Endurance Performance and Induces a Nearly Complete Slow-to-Fast Fiber Transformation on the mRNA Level

    Directory of Open Access Journals (Sweden)

    Julian Eigendorf

    2018-05-01

    Full Text Available We present here a longitudinal study determining the effects of two 3 week-periods of high intensity high volume interval training (HIHVT (90 intervals of 6 s cycling at 250% maximum power, Pmax/24 s on a cycle ergometer. HIHVT was evaluated by comparing performance tests before and after the entire training (baseline, BSL, and endpoint, END and between the two training sets (intermediate, INT. The mRNA expression levels of myosin heavy chain (MHC isoforms and markers of energy metabolism were analyzed in M. vastus lateralis biopsies by quantitative real-time PCR. In incremental tests peak power (Ppeak was increased, whereas V˙O2peak was unaltered. Prolonged time-to-exhaustion was found in endurance tests with 65 and 80% Pmax at INT and END. No changes in blood levels of lipid metabolites were detected. Training-induced decreases of hematocrit indicate hypervolemia. A shift from slow MHCI/β to fast MHCIIa mRNA expression occurred after the first and second training set. The mRNA expression of peroxisome proliferator-activated receptor gamma coactivator 1α (PGC-1α, a master regulator of oxidative energy metabolism, decreased after the second training set. In agreement, a significant decrease was also found for citrate synthase mRNA after the second training set, indicating reduced oxidative capacity. However, mRNA expression levels of glycolytic marker enzyme glyceraldehyde-3-phosphate dehydrogenase did not change after the first and second training set. HIHVT induced a nearly complete slow-to-fast fiber type transformation on the mRNA level, which, however, cannot account for the improvements of performance parameters. The latter might be explained by the well-known effects of hypervolemia on exercise performance.

  18. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training

    Directory of Open Access Journals (Sweden)

    Thomas L. Stöggl

    2017-08-01

    Full Text Available The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR in well-trained endurance athletes.Methods: Thirty-six male (n = 33 and female (n = 3 runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO2peak: 61.9 ± 8.0 mL·kg−1·min−1] were randomly assigned to one of three groups (blocked high intensity interval training HIIT; polarized training POL; high volume low intensity oriented control group CG/HVLIT applying no HIIT. A maximal anaerobic running/cycling test (MART/MACT was performed prior to and following a 9-week training period.Results: Only the HIIT group achieved improvements in peak power/velocity (+6.4%, P < 0.001 and peak lactate (P = 0.001 during the MART/MACT, while, unexpectedly, in none of the groups the performance at the established lactate concentrations (4, 6, 10 mmol·L−1 was changed (P > 0.05. Acute HRR was improved in HIIT (11.2%, P = 0.002 and POL (7.9%, P = 0.023 with no change in the HVLIT oriented control group.Conclusion: Only a training regime that includes a significant amount of HIIT improves the neuromuscular status, anaerobic power and the acute HRR in well-trained endurance athletes. A training regime that followed more a low and moderate intensity oriented model (CG/HVLIT had no effect on any performance or HRR outcomes.

  19. Inter fraction variations in rectum and bladder volumes and dose distributions during high dose rate brachytherapy treatment of the uterine cervix investigated by repetitive CT-examinations

    International Nuclear Information System (INIS)

    Hellebust, Taran Paulsen; Dale, Einar; Skjoensberg, Ane; Olsen, Dag Rune

    2001-01-01

    Purpose: To evaluate variation of dose to organs at risk for patients receiving fractionated high dose rate gynaecological brachytherapy by using CT-based 3D treatment planning and dose-volume histograms (DVH). Materials and methods: Fourteen patients with cancer of the uterine cervix underwent three to six CT examinations (mean 4.9) during their course of high-dose-rate brachytherapy using radiographically compatible applicators. The rectal and bladder walls were delineated and DVHs were calculated. Results: Inter fraction variation of the bladder volume (CV mean =44.1%) was significantly larger than the inter fraction variation of the mean dose (CV mean =19.9%, P=0.005) and the maximum dose (CV mean =17.5%, P=0.003) of the bladder wall. The same trend was seen for rectum, although the figures were not significantly different. Performing CT examinations at four of seven brachytherapy fractions reduced the uncertainty to 4 and 7% for the bladder and rectal doses, respectively. A linear regression analysis showed a significant, negative relationship between time after treatment start and the whole bladder volume (P=0.018), whereas no correlation was found for the rectum. For both rectum and bladder a linear regression analysis revealed a significant, negative relationship between the whole volume and median dose (P<0.05). Conclusion: Preferably a CT examination should be provided at every fraction. However, this is logistically unfeasible in most institutions. To obtain reliable DVHs the patients will in the future undergo 3-4 CT examinations during the course of brachytherapy at our institution. Since this study showed an association between large bladder volumes and dose reductions, the patients will be treated with a standardized bladder volume

  20. Technology of high-level nuclear waste disposal. Advances in the science and engineering of the management of high-level nuclear wastes. Volume 1

    International Nuclear Information System (INIS)

    Hofmann, P.L.; Breslin, J.J.

    1981-01-01

    The papers in this volume cover the following subjects: waste isolation and the natural geohydrologic system; repository perturbations of the natural system; radionuclide migration through the natural system; and repository design technology. Individual papers are abstracted

  1. Technology of high-level nuclear waste disposal. Advances in the science and engineering of the management of high-level nuclear wastes. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, P.L.; Breslin, J.J. (eds.)

    1981-01-01

    The papers in this volume cover the following subjects: waste isolation and the natural geohydrologic system; repository perturbations of the natural system; radionuclide migration through the natural system; and repository design technology. Individual papers are abstracted.

  2. Volume-change-free GeTeN films for high-performance phase-change memory

    International Nuclear Information System (INIS)

    Yin, You; Hosaka, Sumio; Zhang, Hui; Liu, Yang; Yu, Qi

    2013-01-01

    N-doping into GeTe is investigated with the aim of reducing the volume change upon crystallization, which usually induces a huge internal stress in phase-change memory devices. It is demonstrated that the thickness change upon crystallization of a N-doped GeTe (GeTeN) film is almost zero when N is doped in an appropriate amount. Cracks resulting from the stress caused by volume change disappear and the mean crystal size decreases by more than 50% upon N-doping into GeTe. It is thought that the volume-change-free behaviour is due to the formation of low-density nitride and grain refinement. (paper)

  3. The Effects of Design Strength, Fly Ash Content and Curing Method on Compressive Strength of High Volume Fly Ash Concrete: A Design of Experimental

    Directory of Open Access Journals (Sweden)

    Solikin Mochamad

    2017-01-01

    Full Text Available High volume fly ash concrete becomes one of alternatives to produce green concrete as it uses waste material and significantly reduces the utilization of Portland cement in concrete production. Although using less cement, its compressive strength is comparable to ordinary Portland cement (hereafter OPC and the its durability increases significantly. This paper reports investigation on the effect of design strength, fly ash content and curing method on compressive strength of High Volume Fly Ash Concrete. The experiment and data analysis were prepared using minitab, a statistic software for design of experimental. The specimens were concrete cylinder with diameter of 15 cm and height of 30 cm, tested for its compressive strength at 56 days. The result of the research demonstrates that high volume fly ash concrete can produce comparable compressive strength which meets the strength of OPC design strength especially for high strength concrete. In addition, the best mix proportion to achieve the design strength is the combination of high strength concrete and 50% content of fly ash. Moreover, the use of spraying method for curing method of concrete on site is still recommended as it would not significantly reduce the compressive strength result.

  4. High-dose preoperative chemoradiotherapy in esophageal cancer patients does not increase postoperative pulmonary complications: Correlation with dose-volume histogram parameters

    International Nuclear Information System (INIS)

    Hurmuzlu, Meysan; Ovrebo, Kjell; Wentzel-Larsen, Tore; Muren, Ludvig Paul; Viste, Asgaut; Smaaland, Rune

    2010-01-01

    Purpose: To investigate the association of high-dose preoperative chemoradiotherapy (CRT) and dose-volume histogram (DVH) parameters of lungs with incidence of postoperative pulmonary complications and to identify predictive clinical factors of pulmonary complications. Methods: Data of 65 patients were collected retrospectively. Thirty-five patients underwent transthoracic esophagectomy (TTE) alone and 30 received cisplatin and 5-fluorouracil, concomitant with radiotherapy, median dose 66 Gy, and followed by TTE. From the DVH for each lung alone and for both lungs together as one organ we generated total lung volume, mean radiotherapy dose, relative and absolute volumes receiving more than a threshold dose, and relative and absolute volumes receiving less than a threshold dose. Postoperative pulmonary complications were defined as pneumonia or respiratory failure. Results: Sixty percent of the patients in the TTE alone group had postoperative pulmonary complications versus 63% in the CRT + TTE group. Postoperative mortality was 8.6% and 16.7% in the respective patient groups (p = NS). None of the DVH parameters was associated with postoperative pulmonary complications. Squamous cell carcinoma was an adverse factor related to increased postoperative pulmonary complications. Conclusion: High-dose preoperative CRT was not associated with increased postoperative pulmonary complications in this cohort of esophageal cancer patients.

  5. Changes of the liver volume and the Child-Pugh score after high dose hypofractionated radiotherapy in patients with small hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kim, Young Il; Park, Hee Chul; Lim, Do Hoon; Park, Hyo Jung; Park, Su Yeon; Kim, Jin Sung; Han, Young Yih; Kang, Sang Won; Paik, Seung Woon

    2012-01-01

    To investigate the safety of high dose hypofractionated radiotherapy (RT) in patients with small hepatocellular carcinoma (HCC) in terms of liver volumetric changes and clinical liver function. We retrospectively reviewed 16 patients with small HCC who were treated with high dose hypofractionated RT between 2006 and 2009. The serial changes of the liver volumetric parameter were analyzed from pre-RT and follow-up (FU) computed tomography (CT) scans. We estimated linear time trends of whole liver volume using a linear mixed model. The serial changes of the Child-Pugh (CP) scores were also analyzed in relation to the volumetric changes. Mean pre-RT volume of entire liver was 1,192.2 mL (range, 502.6 to 1,310.2 mL) and mean clinical target volume was 14.7 mL (range, 1.56 to 70.07 mL). Fourteen (87.5%) patients had 4 FU CT sets and 2 (12.5%) patients had 3 FU CT sets. Mean interval between FU CT acquisition was 2.5 months. After considering age, gender and the irradiated liver volume as a fixed effects, the mixed model analysis confirmed that the change in liver volume is not significant throughout the time course of FU periods. Majority of patients had a CP score change less than 2 except in 1 patient who had CP score change more than 3. The high dose hypofractionated RT for small HCC is relatively safe and feasible in terms of liver volumetric changes and clinical liver function.

  6. Liver Resections in a High-Volume Center: Form Standard Procedures to Extreme Surgery and Ultrasound-guided Resections.

    Science.gov (United States)

    Botea, Florin; Ionescu, Mihnea; Braşoveanu, Vladislav; Hrehoreţ, Doina; Alexandrescu, Sorin; Grigorie, Mihai; Stanciulea, Oana; Nicolaescu, Diana; Tomescu, Dana; Droc, Gabriela; Ungureanu, Daniela; Fota, Ruxandra; Croitoru, Adina; Gheorghe, Liana; Gheorghe, Cristian; Lupescu, Ioana; Grasu, Mugur; Boroş, Mirela; Dumitru, Radu; Toma, Mihai; Herlea, Vlad; Popescu, Irinel

    2017-01-01

    Background: Liver resection (LR) is the treatment of choice for most benign and malignant focal liver lesions, as well as in selected patients with liver trauma. Few other therapies can compete with LR in selected cases, such as liver transplantation in hepatocellular carcinoma (HCC) and ablative therapies in small HCCs or liver metastases. The present paper analyses a single center experience in LR, reviewing the indications of LR, the operative techniques and their short-term results. Between January 2000 and December 2016, in "œDan Setlacec" Center of General Surgery and Liver Transplantation were performed 3165 LRs in 3016 patients, for pathologic conditions of the liver. In the present series, liver resections for living-donor liver transplantation were excluded. The median age of the patients was 56 years (mean 58 years; range 1-88), with male/female ratio 1524/1492 and adult/pediatric patient ratio 2973/43. Results: Malignant lesions were the main indication for LR (2372 LRs; 74.9%). Among these, colorectal liver metastases were the most frequent indication (952 LRs; 30.1%), followed by hepatocellular carcinoma (575 patients, 18.2%). The highest number of resected tumors per patient was 21, and the median diameter of the largest tumor was 40 mm (mean 51 mm; range 3-250). Major resections rate was 18.6% (588 LRs) and anatomical LRs were performed in 789 patients (24.9%). The median operative time was 180 minutes (mean 204 minutes; range 45-920). The median blood loss was 500 ml (mean 850 ml; range 500-9500), with a transfusion rate of 41.6% (1316 LRs). The morbidity rate was 40.1% (1270 LRs) and the rate of major complications (Dindo-Clavien IIIa or more) was 13.2% (418 LRs). Mortality rate was 4.2% (127 pts). LRs should be performed in specialized high-volume centers to achieve the best results (low morbidity and mortality rates). Celsius.

  7. Pituitary gland volume in patients with schizophrenia, subjects at ultra high-risk of developing psychosis and healthy controls

    DEFF Research Database (Denmark)

    Nordholm, Dorte; Krogh, Jesper; Mondelli, Valeria

    2013-01-01

    A larger pituitary size is thought to reflect a greater activation of the hypothalamic-pituitary-adrenal (HPA) axis, which may be related to an increase in the number and size of corticotroph cells. Some studies, but not all, indicate that pituitary volume increases before or at the onset...

  8. International conference on high-energy physics. Volume 1. Sessions I to III. [Geneva, June 27-July 4, 1979

    Energy Technology Data Exchange (ETDEWEB)

    1980-02-01

    Volume 1 of the conference proceedings contains sessions on neutrino physics and weak interactions, e/sup +/e/sup -/ physics, and theory. Five of the papers have already been cited in ERA, and can be found by reference to the entry CONF-790642-- in the Report Number Index. The remaining 30 will be processed as they are received on the Atomindex tape. (RWR)

  9. Deep Learning Algorithm for Auto-Delineation of High-Risk Oropharyngeal Clinical Target Volumes With Built-In Dice Similarity Coefficient Parameter Optimization Function.

    Science.gov (United States)

    Cardenas, Carlos E; McCarroll, Rachel E; Court, Laurence E; Elgohari, Baher A; Elhalawani, Hesham; Fuller, Clifton D; Kamal, Mona J; Meheissen, Mohamed A M; Mohamed, Abdallah S R; Rao, Arvind; Williams, Bowman; Wong, Andrew; Yang, Jinzhong; Aristophanous, Michalis

    2018-06-01

    Automating and standardizing the contouring of clinical target volumes (CTVs) can reduce interphysician variability, which is one of the largest sources of uncertainty in head and neck radiation therapy. In addition to using uniform margin expansions to auto-delineate high-risk CTVs, very little work has been performed to provide patient- and disease-specific high-risk CTVs. The aim of the present study was to develop a deep neural network for the auto-delineation of high-risk CTVs. Fifty-two oropharyngeal cancer patients were selected for the present study. All patients were treated at The University of Texas MD Anderson Cancer Center from January 2006 to August 2010 and had previously contoured gross tumor volumes and CTVs. We developed a deep learning algorithm using deep auto-encoders to identify physician contouring patterns at our institution. These models use distance map information from surrounding anatomic structures and the gross tumor volume as input parameters and conduct voxel-based classification to identify voxels that are part of the high-risk CTV. In addition, we developed a novel probability threshold selection function, based on the Dice similarity coefficient (DSC), to improve the generalization of the predicted volumes. The DSC-based function is implemented during an inner cross-validation loop, and probability thresholds are selected a priori during model parameter optimization. We performed a volumetric comparison between the predicted and manually contoured volumes to assess our model. The predicted volumes had a median DSC value of 0.81 (range 0.62-0.90), median mean surface distance of 2.8 mm (range 1.6-5.5), and median 95th Hausdorff distance of 7.5 mm (range 4.7-17.9) when comparing our predicted high-risk CTVs with the physician manual contours. These predicted high-risk CTVs provided close agreement to the ground-truth compared with current interobserver variability. The predicted contours could be implemented clinically, with only

  10. Intensity-modulated radiotherapy in patients with locally advanced rectal cancer reduces volume of bowel treated to high dose levels

    International Nuclear Information System (INIS)

    Urbano, M. Teresa Guerrero; Henrys, Anthony J.; Adams, Elisabeth J.; Norman, Andrew R.; Bedford, James L.; Harrington, Kevin J.; Nutting, Christopher M.; Dearnaley, David P.; Tait, Diana M.

    2006-01-01

    Purpose: To investigate the potential for intensity-modulated radiotherapy (IMRT) to spare the bowel in rectal tumors. Methods and Materials: The targets (pelvic nodal and rectal volumes), bowel, and bladder were outlined in 5 patients. All had conventional, three-dimensional conformal RT and forward-planned multisegment three-field IMRT plans compared with inverse-planned simultaneous integrated boost nine-field equally spaced IMRT plans. Equally spaced seven-field and five-field and five-field, customized, segmented IMRT plans were also evaluated. Results: Ninety-five percent of the prescribed dose covered at least 95% of both planning target volumes using all but the conventional plan (mean primary and pelvic planning target volume receiving 95% of the prescribed dose was 32.8 ± 13.7 Gy and 23.7 ± 4.87 Gy, respectively), reflecting a significant lack of coverage. The three-field forward planned IMRT plans reduced the volume of bowel irradiated to 45 Gy and 50 Gy by 26% ± 16% and 42% ± 27% compared with three-dimensional conformal RT. Additional reductions to 69 ± 51 cm 3 to 45 Gy and 20 ± 21 cm 3 to 50 Gy were obtained with the nine-field equally spaced IMRT plans-64% ± 11% and 64% ± 20% reductions compared with three-dimensional conformal RT. Reducing the number of beams and customizing the angles for the five-field equally spaced IMRT plan did not significantly reduce bowel sparing. Conclusion: The bowel volume irradiated to 45 Gy and 50 Gy was significantly reduced with IMRT, which could potentially lead to less bowel toxicity. Reducing the number of beams did not reduce bowel sparing and the five-field customized segmented IMRT plan is a reasonable technique to be tested in clinical trials

  11. High order well-balanced finite volume WENO schemes and discontinuous Galerkin methods for a class of hyperbolic systems with source terms

    International Nuclear Information System (INIS)

    Xing Yulong; Shu Chiwang

    2006-01-01

    Hyperbolic balance laws have steady state solutions in which the flux gradients are nonzero but are exactly balanced by the source term. In our earlier work [J. Comput. Phys. 208 (2005) 206-227; J. Sci. Comput., accepted], we designed a well-balanced finite difference weighted essentially non-oscillatory (WENO) scheme, which at the same time maintains genuine high order accuracy for general solutions, to a class of hyperbolic systems with separable source terms including the shallow water equations, the elastic wave equation, the hyperbolic model for a chemosensitive movement, the nozzle flow and a two phase flow model. In this paper, we generalize high order finite volume WENO schemes and Runge-Kutta discontinuous Galerkin (RKDG) finite element methods to the same class of hyperbolic systems to maintain a well-balanced property. Finite volume and discontinuous Galerkin finite element schemes are more flexible than finite difference schemes to treat complicated geometry and adaptivity. However, because of a different computational framework, the maintenance of the well-balanced property requires different technical approaches. After the description of our well-balanced high order finite volume WENO and RKDG schemes, we perform extensive one and two dimensional simulations to verify the properties of these schemes such as the exact preservation of the balance laws for certain steady state solutions, the non-oscillatory property for general solutions with discontinuities, and the genuine high order accuracy in smooth regions

  12. Volume of high-risk intratumoral subregions at multi-parametric MR imaging predicts overall survival and complements molecular analysis of glioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Yi; Li, Ruijiang [Stanford University, Department of Radiation Oncology, Palo Alto, CA (United States); Hokkaido University, Global Station for Quantum Medical Science and Engineering, Global Institution for Collaborative Research and Education, Hokkaido (Japan); Ren, Shangjie [Tianjin University, School of Electrical Engineering and Automation, Tianjin Shi (China); Tha, Khin Khin; Shirato, Hiroki [Hokkaido University, Global Station for Quantum Medical Science and Engineering, Global Institution for Collaborative Research and Education, Hokkaido (Japan); Hokkaido University, Department of Radiology and Nuclear Medicine, Hokkaido (Japan); Wu, Jia [Stanford University, Department of Radiation Oncology, Palo Alto, CA (United States)

    2017-09-15

    To develop and validate a volume-based, quantitative imaging marker by integrating multi-parametric MR images for predicting glioblastoma survival, and to investigate its relationship and synergy with molecular characteristics. We retrospectively analysed 108 patients with primary glioblastoma. The discovery cohort consisted of 62 patients from the cancer genome atlas (TCGA). Another 46 patients comprising 30 from TCGA and 16 internally were used for independent validation. Based on integrated analyses of T1-weighted contrast-enhanced (T1-c) and diffusion-weighted MR images, we identified an intratumoral subregion with both high T1-c and low ADC, and accordingly defined a high-risk volume (HRV). We evaluated its prognostic value and biological significance with genomic data. On both discovery and validation cohorts, HRV predicted overall survival (OS) (concordance index: 0.642 and 0.653, P < 0.001 and P = 0.038, respectively). HRV stratified patients within the proneural molecular subtype (log-rank P = 0.040, hazard ratio = 2.787). We observed different OS among patients depending on their MGMT methylation status and HRV (log-rank P = 0.011). Patients with unmethylated MGMT and high HRV had significantly shorter survival (median survival: 9.3 vs. 18.4 months, log-rank P = 0.002). Volume of the high-risk intratumoral subregion identified on multi-parametric MRI predicts glioblastoma survival, and may provide complementary value to genomic information. (orig.)

  13. Efficacy of thermal treatment and copper-silver ionization for controlling Legionella pneumophila in high-volume hot water plumbing systems in hospitals.

    Science.gov (United States)

    Mietzner, S; Schwille, R C; Farley, A; Wald, E R; Ge, J H; States, S J; Libert, T; Wadowsky, R M; Miuetzner, S

    1997-12-01

    Thermal treatment and copper-silver ionization are often used for controlling Legionella pneumophila in high-volume hospital plumbing systems, although the comparative efficacies of these measures in high-volume systems are unknown. Thermal treatment of a hot water circuit was accomplished by flushing hot water (> 60 degrees C) through distal fixtures for 10 minutes. Copper-silver ionization was conducted in three circuits by installing units into return lines immediately upstream from hot water tanks. Recovery rates of L. pneumophila were monitored by culturing swab samples from faucets. Concentrations of copper and silver in water samples were determined by atomic absorption spectrophotometry. Four heat-flush treatments failed to provide long-term control of L. pneumophila. In contrast, ionization treatment reduced the rate of recovery of L. pneumophila from 108 faucets from 72% to 2% within 1 month and maintained effective control for at least 22 months. Only three samples (1.9%) of hot water from faucets exceeded Environmental Protection Agency standards for silver, and none exceeded the standards for copper. Of 24 samples obtained from hot water tanks, 42% and 50% exceeded the silver and copper standards, respectively. Copper-silver ionization effectively controls L. pneumophila in high-volume plumbing systems and is superior to thermal treatment; however, high concentrations of copper and silver can accumulate at the bottom of hot water tanks.

  14. Automation of registration of sample weights for high-volume neutron activation analysis at the IBR-2 reactor of FLNP, JINR

    International Nuclear Information System (INIS)

    Dmitriev, A.Yu.; Dmitriev, F.A.

    2015-01-01

    The 'Weight' software tool was created at FLNP JINR to automate the reading of analytical balance readouts and saving these values in the NAA database. The analytical balance connected to the personal computer is used to measure weight values. The 'Weight' software tool controls the reading of weight values and the exchange of information with the NAA database. The weighing process of a large amount of samples is reliably provided during high-volume neutron activation analysis. [ru

  15. Operating range, hold-up, droplet size and axial mixing of pulsed plate columns in highly disperse and low-continuity volume flows

    International Nuclear Information System (INIS)

    Schmidt, H.; Miller, H.

    Operating behavior, hold-up, droplet size and axial mixing are investigated in highly disperse and slightly continuous volume flows in a pulsed plate column. The geometry of the column of 4-m length and 10-cm inside diameter was held constant. The hole shape of the column bases was changed, wherby the cylindrical, sharp-edge drilled hole is compared with the punched, nozzle-shaped hole in their effects on the fluid-dynamic behavior. In this case we varied the volume flows, the ratio of volume flows, the pulse frequency and the operating temperature. The operation was held constant for the aqueous, the organic, the continuous and the disperse phases. The objective was to demonstrate the applicability of pulsed plate columns with very large differences between the organic disperse and the aqueous continuous volume flow, to obtain design data for such columns and to perform a scale-up to industrial reprocessing plant-size. 18 references, 11 figures, 3 tables

  16. Server-based enterprise collaboration software improves safety and quality in high-volume PET/CT practice.

    Science.gov (United States)

    McDonald, James E; Kessler, Marcus M; Hightower, Jeremy L; Henry, Susan D; Deloney, Linda A

    2013-12-01

    With increasing volumes of complex imaging cases and rising economic pressure on physician staffing, timely reporting will become progressively challenging. Current and planned iterations of PACS and electronic medical record systems do not offer workflow management tools to coordinate delivery of imaging interpretations with the needs of the patient and ordering physician. The adoption of a server-based enterprise collaboration software system by our Division of Nuclear Medicine has significantly improved our efficiency and quality of service.

  17. Construction of a liposome dialyzer for the preparation of high-value, small-volume liposome formulations.

    Science.gov (United States)

    Adamala, Katarzyna; Engelhart, Aaron E; Kamat, Neha P; Jin, Lin; Szostak, Jack W

    2015-06-01

    The liposome dialyzer is a small-volume equilibrium dialysis device, built from commercially available materials, that is designed for the rapid exchange of small volumes of an extraliposomal reagent pool against a liposome preparation. The dialyzer is prepared by modification of commercially available dialysis cartridges (Slide-A-Lyzer cassettes), and it consists of a reactor with two 300-μl chambers and a 1.56-cm(2) dialysis surface area. The dialyzer is prepared in three stages: (i) disassembling the dialysis cartridges to obtain the required parts, (ii) assembling the dialyzer and (iii) sealing the dialyzer with epoxy. Preparation of the dialyzer takes ∼1.5 h, not including overnight epoxy curing. Each round of dialysis takes 1-24 h, depending on the analyte and membrane used. We previously used the dialyzer for small-volume non-enzymatic RNA synthesis reactions inside fatty acid vesicles. In this protocol, we demonstrate other applications, including removal of unencapsulated calcein from vesicles, remote loading and vesicle microscopy.

  18. A Highly Stable Marching-on-in-Time Volume Integral Equation Solver for Analyzing Transient Wave Interactions on High-Contrast Scatterers

    KAUST Repository

    Bagci, Hakan

    2014-01-06

    Time domain integral equation (TDIE) solvers represent an attractive alternative to finite difference (FDTD) and finite element (FEM) schemes for analyzing transient electromagnetic interactions on composite scatterers. Current induced on a scatterer, in response to a transient incident field, generates a scattered field. First, the scattered field is expressed as a spatio-temporal convolution of the current and the Green function of the background medium. Then, a TDIE is obtained by enforcing boundary conditions and/or fundamental field relations. TDIEs are often solved for the unknown current using marching on-in-time (MOT) schemes. MOT-TDIE solvers expand the current using local spatio-temporal basis functions. Inserting this expansion into the TDIE and testing the resulting equation in space and time yields a lower triangular system of equations (termed MOT system), which can be solved by marching in time for the coefficients of the current expansion. Stability of the MOT scheme often depends on how accurately the spatio-temporal convolution of the current and the Green function is discretized. In this work, band-limited prolate-based interpolation functions are used as temporal bases in expanding the current and discretizing the spatio-temporal convolution. Unfortunately, these functions are two sided, i.e., they require ”future” current samples for interpolation, resulting in a non-causal MOT system. To alleviate the effect of non-causality and restore the ability to march in time, an extrapolation scheme can be used to estimate the future values of the currents from their past values. Here, an accurate, stable and band-limited extrapolation scheme is developed for this purpose. This extrapolation scheme uses complex exponents, rather than commonly used harmonics, so that propagating and decaying mode fields inside the dielectric scatterers are accurately modeled. The resulting MOT scheme is applied to solving the time domain volume integral equation (VIE

  19. Technology of high-level nuclear waste disposal. Advances in the science and engineering of the management of high-level nuclear wastes. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, P.L. (ed.)

    1982-01-01

    The twenty papers in this volume are divided into three parts: site exploration and characterization; repository development and design; and waste package development and design. These papers represent the status of technology that existed in 1981 and 1982. Individual papers were processed for inclusion in the Energy Data Base.

  20. Technology of high-level nuclear waste disposal. Advances in the science and engineering of the management of high-level nuclear wastes. Volume 2

    International Nuclear Information System (INIS)

    Hofmann, P.L.

    1982-01-01

    The twenty papers in this volume are divided into three parts: site exploration and characterization; repository development and design; and waste package development and design. These papers represent the status of technology that existed in 1981 and 1982. Individual papers were processed for inclusion in the Energy Data Base

  1. High, but not low, exercise volume shifts the balance of renin-angiotensin system toward ACE2/Mas receptor axis in skeletal muscle in obese rats.

    Science.gov (United States)

    Frantz, Eliete Dalla Corte; Giori, Isabele Gomes; Machado, Marcus Vinícius; Magliano, D'Angelo Carlo; Freitas, Fernanda Marques; Andrade, Mariana Sodré Boêta; Vieira, Aline Bomfim; Nóbrega, Antonio Claudio Lucas; Tibiriçá, Eduardo

    2017-10-01

    Metabolic syndrome is a cluster of metabolic risk factors that is linked to central obesity, elevated blood pressure, insulin resistance (IR), and dyslipidemia, where the renin-angiotensin system (RAS) may provide a link among them. This study aimed to evaluate volume exercise effects comparing low vs. high volume of chronic aerobic exercise on RAS axes in skeletal muscle in a diet-induced obesity (DIO) rat model. For this, male Wistar-Kyoto rats were fed a standard chow (SC) diet or a high-fat (HF) diet for 32 wk. Animals receiving the HF diet were randomly divided into low exercise volume (LEV, 150 min/wk) and high exercise volume (HEV, 300 min/wk) at the 20th week. After 12 wk of aerobic treadmill training, the body mass and composition, blood pressure, glucose and lipid metabolism, RAS axes, insulin signaling, and inflammatory pathway were performed. HEV slowed the body mass gain, reduced intra-abdominal fat pad and leptin levels, improved total and peripheral body composition and inflammatory cytokine, reduced angiotensin II type 1 receptor expression, and increased Mas receptor protein expression compared with the HF animals. Sedentary groups (SC and HF) presented lower time to exhaustion and maximal velocity compared with the LEV and HEV groups. Both exercise training groups showed reduced resting systolic blood pressure and heart rate, improved glucose tolerance, IR, insulin signaling, and lipid profile. We conclude that the HEV, but not LEV, shifted the balance of RAS toward the ACE2/Mas receptor axis in skeletal muscle, presenting protective effects against the DIO model. Copyright © 2017 the American Physiological Society.

  2. Dosimetric Coverage of the Prostate, Normal Tissue Sparing, and Acute Toxicity with High-Dose-Rate Brachytherapy for Large Prostate Volumes

    Directory of Open Access Journals (Sweden)

    George Yang

    2015-06-01

    Full Text Available ABSTRACTPurposeTo evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes.Materials and MethodsOne hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL were treated with high-dose-rate (HDR brachytherapy ± intensity modulated radiation therapy (IMRT to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38% unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE version 4.ResultsMedian follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3% patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17% patients developed Grade 2 acute urinary retention. American Urological Association (AUA symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p=0.04. There was no ≥ Grade 3 acute toxicity.ConclusionsDosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes.

  3. Dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with high-dose-rate brachytherapy for large prostate volumes

    Energy Technology Data Exchange (ETDEWEB)

    Yang, George; Strom, Tobin J.; Shrinath, Kushagra; Mellon, Eric A.; Fernandez, Daniel C.; Biagioli, Matthew C. [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Wilder, Richard B., E-mail: mcbiagioli@yahoo.com [Cancer Treatment Centers of America, Newnan, GA (United States)

    2015-05-15

    Purpose: to evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes. Materials and methods: one hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL) were treated with high-dose-rate (HDR) brachytherapy ± intensity modulated radiation therapy (IMRT) to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38%) unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE) version 4. Results: median follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3%) patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17%) patients developed Grade 2 acute urinary retention. American Urological Association (AUA) symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p-0.04). There was no ≥ Grade 3 acute toxicity. Conclusions: dosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes. (author)

  4. Analysis of dose volume histogram parameters to estimate late bladder and rectum complications after high-dose (70-78 Gy) conformal radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Boersma, L.J.; Brink, M. van den; Bruce, A.; Gras, L.; Velde, A. te; Lebesque, J.V.

    1997-01-01

    Purpose: To investigate whether Dose Volume Histogram (DVH) parameters can be used to identify risk groups for developing late gastrointestinal (GI) and genitourinary (GU) complications after conformal radiotherapy for prostate cancer, and to examine the effect of using different morbidity scoring systems on the results of these analyses. Materials and Methods: DVH parameters were analyzed for 130 patients with localized prostate cancer, treated with conformal radiotherapy in a dose-escalating protocol (70-78 Gy, 2 Gy per fraction). The incidence of late (> 6 months) GI and GU complications was scored based on questionnaires and classified using the RTOG/EORTC and the SOMA/LENT scoring system. Moreover, patients were classified as being a rectal bleeder or no rectal bleeder and a distinction was made between non-severe and severe (requiring one or more laser treatments) rectal bleeding. The median follow-up time was 22 months. It was investigated whether the relative and absolute rectal wall volumes, irradiated to various dose levels (≥ 60 Gy, ≥ 65 Gy, ≥ 70 Gy and ≥ 75 Gy) were correlated with the observed actuarial incidences of GI complications. First, the analysis was performed using volume as a continuous variable. Subsequently, for each dose level in the DVH the rectal wall volumes were dichotomized using different volumes as cut-off levels. Twenty cut-off levels were tested on their ability to discriminate between high and low risk for developing GI complications (Fig.). The relationship between bladder wall volumes irradiated to various dose levels and observed actuarial GU complications was investigated using the absolute bladder wall volumes, measured as a continuous variable. For both GI and GU complications, the role of the prescribed radiation dose and the maximum radiation dose in the rectal and bladder wall was analyzed as well. Results: None of the DVH parameters of the rectal wall was significantly correlated with the actuarial incidences of

  5. Estimation of the incidence of late bladder and rectum complications after high-dose (70-78 Gy) conformal radiotherapy for prostate cancer, using dose-volume histograms

    International Nuclear Information System (INIS)

    Boersma, Liesbeth J.; Brink, Mandy van den; Bruce, Allison M.; Shouman, Tarek; Gras, Luuk; Velde, Annet te; Lebesque, Joos V.

    1998-01-01

    Purpose: To investigate whether Dose-Volume Histogram (DVH) parameters can be used to identify risk groups for developing late gastrointestinal (GI) and genitourinary (GU) complications after conformal radiotherapy for prostate cancer. Methods and Materials: DVH parameters were analyzed for 130 patients with localized prostate cancer, treated with conformal radiotherapy in a dose-escalating protocol (70-78 Gy, 2 Gy per fraction). The incidence of late (>6 months) GI and GU complications was classified using the RTOG/EORTC and the SOMA/LENT scoring system. In addition, GI complications were divided in nonsevere and severe (requiring one or more laser treatments or blood transfusions) rectal bleeding. The median follow-up time was 24 months. We investigated whether rectal and bladder wall volumes, irradiated to various dose levels, correlated with the observed actuarial incidences of GI and GU complications, using volume as a continuous variable. Subsequently, for each dose level in the DVH, the rectal wall volumes were dichotomized using different volumes as cutoff levels. The impact of the total radiation dose, and the maximum radiation dose in the rectal and bladder wall was analyzed as well. Results: The actuarial incidence at 2 years for GI complications ≥Grade II was 14% (RTOG/EORTC) or 20% (SOMA/LENT); for GU complications ≥Grade III 8% (RTOG/EORTC) or 21% (SOMA/LENT). Neither for GI complications ≥Grade II (RTOG/EORTC or SOMA/LENT), nor for GU complications ≥Grade III (RTOG/EORTC or SOMA/LENT), was a significant correlation found between any of the DVH parameters and the actuarial incidence of complications. For severe rectal bleeding (actuarial incidence at 2 years 3%), four consecutive volume cutoff levels were found, which significantly discriminated between high and low risk. A trend was observed that a total radiation dose ≥ 74 Gy (or a maximum radiation dose in the rectal wall >75 Gy) resulted in a higher incidence of severe rectal bleeding (p

  6. Improving visit cycle time using patient flow analysis in a high-volume inner-city hospital-based ambulatory clinic serving minority New Yorkers.

    Science.gov (United States)

    Dhar, Sanjay; Michel, Raquel; Kanna, Balavenkatesh

    2011-01-01

    Patient waiting time and waiting room congestion are quality indicators that are related to efficiency of ambulatory care systems and patient satisfaction. Our main purpose was to test a program to decrease patient visit cycle time, while maintaining high-quality healthcare in a high-volume inner-city hospital-based clinic in New York City. Use of patient flow analysis and the creation of patient care teams proved useful in identifying areas for improvement, target, and measure effectiveness of interventions. The end result is reduced visit cycle time, improved provider team performance, and sustained patient care outcomes. © 2010 National Association for Healthcare Quality.

  7. High performance liquid chromatography column efficiency enhancement by zero dead volume recycling and practical approach using park and recycle arrangement.

    Science.gov (United States)

    Minarik, Marek; Franc, Martin; Minarik, Milan

    2018-06-15

    A new instrumental approach to recycling HPLC is described. The concept is based on fast reintroduction of incremental peak sections back onto the separation column. The re-circulation is performed within a closed loop containing only the column and two synchronized switching valves. By having HPLC pump out of the cycle, the method minimizes peak broadening due to dead volume. As a result the efficiency is dramatically increased allowing for the most demanding analytical applications. In addition, a parking loop is employed for temporary storage of analytes from the middle section of the separated mixture prior to their recycling. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Volume labeling with Alexa Fluor dyes and surface functionalization of highly sensitive fluorescent silica (SiO2) nanoparticles

    Science.gov (United States)

    Wang, Wei; Nallathamby, Prakash D.; Foster, Carmen M.; Morrell-Falvey, Jennifer L.; Mortensen, Ninell P.; Doktycz, Mitchel J.; Gu, Baohua; Retterer, Scott T.

    2013-10-01

    A new synthesis approach is described that allows the direct incorporation of fluorescent labels into the volume or body of SiO2 nanoparticles. In this process, fluorescent Alexa Fluor dyes with different emission wavelengths were covalently incorporated into the SiO2 nanoparticles during their formation by the hydrolysis of tetraethoxysilane. The dye molecules were homogeneously distributed throughout the SiO2 nanoparticles. The quantum yields of the Alexa Fluor volume-labeled SiO2 nanoparticles were much higher than nanoparticles labeled using conventional organic dyes. The size of the resulting nanoparticles was controlled using microemulsion reaction media with sizes in the range of 20-100 nm and a polydispersity of cultured macrophages. Differences in particle agglomeration and cell association were clearly associated with differences in observed nanoparticle toxicity. The capacity to maintain particle fluorescence while making significant changes to surface chemistry makes these particles extremely versatile and useful for studies of particle agglomeration, uptake, and transport in environmental and biological systems.A new synthesis approach is described that allows the direct incorporation of fluorescent labels into the volume or body of SiO2 nanoparticles. In this process, fluorescent Alexa Fluor dyes with different emission wavelengths were covalently incorporated into the SiO2 nanoparticles during their formation by the hydrolysis of tetraethoxysilane. The dye molecules were homogeneously distributed throughout the SiO2 nanoparticles. The quantum yields of the Alexa Fluor volume-labeled SiO2 nanoparticles were much higher than nanoparticles labeled using conventional organic dyes. The size of the resulting nanoparticles was controlled using microemulsion reaction media with sizes in the range of 20-100 nm and a polydispersity of cultured macrophages. Differences in particle agglomeration and cell association were clearly associated with differences in

  9. A true minimally invasive approach for cochlear implantation: high accuracy in cranial base navigation through flat-panel-based volume computed tomography.

    Science.gov (United States)

    Majdani, Omid; Bartling, Soenke H; Leinung, Martin; Stöver, Timo; Lenarz, Minoo; Dullin, Christian; Lenarz, Thomas

    2008-02-01

    High-precision intraoperative navigation using high-resolution flat-panel volume computed tomography makes feasible the possibility of minimally invasive cochlear implant surgery, including cochleostomy. Conventional cochlear implant surgery is typically performed via mastoidectomy with facial recess to identify and avoid damage to vital anatomic landmarks. To accomplish this procedure via a minimally invasive approach--without performing mastoidectomy--in a precise fashion, image-guided technology is necessary. With such an approach, surgical time and expertise may be reduced, and hearing preservation may be improved. Flat-panel volume computed tomography was used to scan 4 human temporal bones. A drilling channel was planned preoperatively from the mastoid surface to the round window niche, providing a margin of safety to all functional important structures (e.g., facial nerve, chorda tympani, incus). Postoperatively, computed tomographic imaging and conventional surgical exploration of the drilled route to the cochlea were performed. All 4 specimens showed a cochleostomy located at the scala tympani anterior inferior to the round window. The chorda tympani was damaged in 1 specimen--this was preoperatively planned as a narrow facial recess was encountered. Using flat-panel volume computed tomography for image-guided surgical navigation, we were able to perform minimally invasive cochlear implant surgery defined as a narrow, single-channel mastoidotomy with cochleostomy. Although this finding is preliminary, it is technologically achievable.

  10. Use of a new tandem cation/anion exchange system with clinical-scale generators provides high specific volume solutions of technetium-99m and rhenium-188

    International Nuclear Information System (INIS)

    Knapp, F.R. Jr.; Beets, A.L.; Mirzadeh, S.; Guhlke, S.; Univ. of Bonn

    1998-03-01

    In this paper the authors describe the first application of a simple and inexpensive post elution tandem cation-anion exchange column system which is based on generator elution with salts of weak acids such as ammonium acetate instead of saline solution to provide very high specific volume solutions of technetium-99m and rhenium-188 from clinical scale molybdenum-99/technetium-99m generator prepared from low specific activity (n,y) molybdenum-99, and tungsten-188/rhenium-188 generators, respectively. Initial passage of the bolus through a strong cation exchange cartridge converts the ammonium acetate to acetic acid which is essentially not ionized at the acidic pH, allowing specific subsequent amine type (QMA SepPak trademark) anion exchange cartridge column trapping of the microscopic levels of the pertechnetate or perrhenate. Subsequent elution of the anion cartridge with a small volume ( 500 mCi/mL) from the alumina-based tungsten-188/rhenium-188 generator

  11. Feasibility of disposal of high-level radioactive waste into the seabed. volume 7: Review of laboratory investigations of radionuclide migration through deep-sea sediments

    International Nuclear Information System (INIS)

    Brush, L.H.

    1988-01-01

    One of the options suggested for disposal of high-level radioactive waste resulting from the generation of nuclear power is burial beneath the deep ocean floor in geologically stable sediment formations which have no economic value. The 8-volume series provides an assessment of the technical feasibility and radiological safety of this disposal concept based on the results obtained by ten years of co-operation and information exchange among the Member countries participating in the NEA Seabed Working Group. This volume contains a review of the laboratory investigations of radionuclide migration through deep-sea sediments. In addition, it discusses the data selected for the radiological assessment, on the basis of both field and laboratory studies

  12. Proceedings of the twenty-fourth water reactor safety information meeting. Volume 1: Plenary session; High burnup fuel; Containment and structural aging

    International Nuclear Information System (INIS)

    Monteleone, S.

    1997-01-01

    This three-volume report contains papers presented at the Twenty-Fourth Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, maryland, October 21--23, 1996. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from Czech Republic, Finland, France, Japan, Norway, Russia and United Kingdom. This first volume is divided into 3 sections: plenary session; high burnup fuel; and containment and structural aging. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database

  13. Proceedings of the twenty-fourth water reactor safety information meeting. Volume 1: Plenary session; High burnup fuel; Containment and structural aging

    Energy Technology Data Exchange (ETDEWEB)

    Monteleone, S. [comp.] [Brookhaven National Lab., Upton, NY (United States)

    1997-01-01

    This three-volume report contains papers presented at the Twenty-Fourth Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, maryland, October 21--23, 1996. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from Czech Republic, Finland, France, Japan, Norway, Russia and United Kingdom. This first volume is divided into 3 sections: plenary session; high burnup fuel; and containment and structural aging. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  14. Analytical performance evaluation of a high-volume hematology laboratory utilizing sigma metrics as standard of excellence.

    Science.gov (United States)

    Shaikh, M S; Moiz, B

    2016-04-01

    Around two-thirds of important clinical decisions about the management of patients are based on laboratory test results. Clinical laboratories are required to adopt quality control (QC) measures to ensure provision of accurate and precise results. Six sigma is a statistical tool, which provides opportunity to assess performance at the highest level of excellence. The purpose of this study was to assess performance of our hematological parameters on sigma scale in order to identify gaps and hence areas of improvement in patient care. Twelve analytes included in the study were hemoglobin (Hb), hematocrit (Hct), red blood cell count (RBC), mean corpuscular volume (MCV), red cell distribution width (RDW), total leukocyte count (TLC) with percentages of neutrophils (Neutr%) and lymphocytes (Lymph %), platelet count (Plt), mean platelet volume (MPV), prothrombin time (PT), and fibrinogen (Fbg). Internal quality control data and external quality assurance survey results were utilized for the calculation of sigma metrics for each analyte. Acceptable sigma value of ≥3 was obtained for the majority of the analytes included in the analysis. MCV, Plt, and Fbg achieved value of performed poorly on both level 1 and 2 controls with sigma value of <3. Despite acceptable conventional QC tools, application of sigma metrics can identify analytical deficits and hence prospects for the improvement in clinical laboratories. © 2016 John Wiley & Sons Ltd.

  15. Stereotactic body radiotherapy and treatment at a high volume facility is associated with improved survival in patients with inoperable stage I non-small cell lung cancer

    International Nuclear Information System (INIS)

    Koshy, Matthew; Malik, Renuka; Mahmood, Usama; Husain, Zain; Sher, David J.

    2015-01-01

    Background: This study examined the comparative effectiveness of no treatment (NoTx), conventional fractionated radiotherapy (ConvRT), and stereotactic body radiotherapy (SBRT) in patients with inoperable stage I non-small cell lung cancer. This population based cohort also allowed us to examine what facility level characteristics contributed to improved outcomes. Methods: We included patients in the National Cancer Database from 2003 to 2006 with T1-T2N0M0 inoperable lung cancer (n = 13,036). Overall survival (OS) was estimated using Kaplan–Meier methods and Cox proportional hazard regression. Results: The median follow up was 68 months (interquartile range: 35–83 months) in surviving patients. Among the cohort, 52% received NoTx, 41% received ConvRT and 6% received SBRT. The 3-year OS was 28% for NoTx, 36% for ConvRT radiotherapy, and 48% for the SBRT cohort (p < 0.0001). On multivariate analysis, the hazard ratio for SBRT and ConvRT were 0.67 and 0.77, respectively, as compared to NoTx (1.0 ref) (p < 0.0001). Patients treated at a high volume facility vs. low volume facility had a hazard ratio of 0.94 vs. 1.0 (p = 0.01). Conclusions: Patients with early stage inoperable lung cancer treated with SBRT and at a high volume facility had a survival benefit compared to patients treated with ConvRT or NoTx or to those treated at a low volume facility

  16. Multiplexing spheroid volume, resazurin and acid phosphatase viability assays for high-throughput screening of tumour spheroids and stem cell neurospheres.

    Directory of Open Access Journals (Sweden)

    Delyan P Ivanov

    Full Text Available Three-dimensional cell culture has many advantages over monolayer cultures, and spheroids have been hailed as the best current representation of small avascular tumours in vitro. However their adoption in regular screening programs has been hindered by uneven culture growth, poor reproducibility and lack of high-throughput analysis methods for 3D. The objective of this study was to develop a method for a quick and reliable anticancer drug screen in 3D for tumour and human foetal brain tissue in order to investigate drug effectiveness and selective cytotoxic effects. Commercially available ultra-low attachment 96-well round-bottom plates were employed to culture spheroids in a rapid, reproducible manner amenable to automation. A set of three mechanistically different methods for spheroid health assessment (Spheroid volume, metabolic activity and acid phosphatase enzyme activity were validated against cell numbers in healthy and drug-treated spheroids. An automated open-source ImageJ macro was developed to enable high-throughput volume measurements. Although spheroid volume determination was superior to the other assays, multiplexing it with resazurin reduction and phosphatase activity produced a richer picture of spheroid condition. The ability to distinguish between effects on malignant and the proliferating component of normal brain was tested using etoposide on UW228-3 medulloblastoma cell line and human neural stem cells. At levels below 10 µM etoposide exhibited higher toxicity towards proliferating stem cells, whereas at concentrations above 10 µM the tumour spheroids were affected to a greater extent. The high-throughput assay procedures use ready-made plates, open-source software and are compatible with standard plate readers, therefore offering high predictive power with substantial savings in time and money.

  17. Information needs for characterization of high-level waste repository sites in six geologic media. Volume 2. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1985-05-01

    Volume II contains appendices for the following: (1) remote sensing and surface mapping techniques; (2) subsurface mapping methods for site characterization; (3) gravity technique; (4) audio-frequency magnetotelluric technique; (5) seismic refraction technique; (6) direct-current electrical resistivity method; (7) magnetic technique; (8) seismic reflection technique; (9) seismic crosshole method; (10) mechanical downhole seismic velocity survey method; (11) borehole geophysical logging techniques; (12) drilling and coring methods for precharacterization studies; (13) subsurface drilling methods for site characterization; (14) geomechanical/thermomechanical techniques for precharacterization studies; (15)geomechanical/thermal techniques for site characterization studies; (16) exploratory geochemical techniques for precharacterization studies; (17) geochemical techniques for site characterization; (18) hydrologic techniques for precharacterization studies; (19) hydrologic techniques for site characterization; and (20) seismological techniques.

  18. Information needs for characterization of high-level waste repository sites in six geologic media. Volume 2. Appendices

    International Nuclear Information System (INIS)

    1985-05-01

    Volume II contains appendices for the following: (1) remote sensing and surface mapping techniques; (2) subsurface mapping methods for site characterization; (3) gravity technique; (4) audio-frequency magnetotelluric technique; (5) seismic refraction technique; (6) direct-current electrical resistivity method; (7) magnetic technique; (8) seismic reflection technique; (9) seismic crosshole method; (10) mechanical downhole seismic velocity survey method; (11) borehole geophysical logging techniques; (12) drilling and coring methods for precharacterization studies; (13) subsurface drilling methods for site characterization; (14) geomechanical/thermomechanical techniques for precharacterization studies; (15)geomechanical/thermal techniques for site characterization studies; (16) exploratory geochemical techniques for precharacterization studies; (17) geochemical techniques for site characterization; (18) hydrologic techniques for precharacterization studies; (19) hydrologic techniques for site characterization; and (20) seismological techniques

  19. Ablation of clinically relevant kidney tissue volumes by high-intensity focused ultrasound: Preliminary results of standardized ex-vivo investigations.

    Science.gov (United States)

    Häcker, Axel; Peters, Kristina; Knoll, Thomas; Marlinghaus, Ernst; Alken, Peter; Jenne, Jürgen W; Michel, Maurice Stephan

    2006-11-01

    To investigate strategies to achieve confluent kidney-tissue ablation by high-intensity focused ultrasound (HIFU). Our model of the perfused ex-vivo porcine kidney was used. Tissue ablation was performed with an experimental HIFU device (Storz Medical, Kreuzlingen, Switzerland). Lesion-to-lesion interaction was investigated by varying the lesion distance (5 to 2.5 mm), generator power (300, 280, and 260 W), cooling time (10, 20, and 30 seconds), and exposure time (4, 3, and 2 seconds). The lesion rows were analyzed grossly and by histologic examination (hematoxylin-eosin and nicotinamide adenine dinucleotide staining). It was possible to achieve complete homogeneous ablation of a clinically relevant tissue volume but only by meticulous adjustment of the exposure parameters. Minimal changes in these parameters caused changes in lesion formation with holes within the lesions and lesion-to-lesion interaction. Our preliminary results show that when using this new device, HIFU can ablate a large tissue volume homogeneously in perfused ex-vivo porcine tissue under standardized conditions with meticulous adjustment of exposure parameters. Further investigations in vivo are necessary to test whether large tissue volumes can be ablated completely and reliably despite the influence of physiologic tissue and organ movement.

  20. Robotic Assisted Simple Prostatectomy versus Holmium Laser Enucleation of the Prostate for Lower Urinary Tract Symptoms in Patients with Large Volume Prostate: A Comparative Analysis from a High Volume Center.

    Science.gov (United States)

    Umari, Paolo; Fossati, Nicola; Gandaglia, Giorgio; Pokorny, Morgan; De Groote, Ruben; Geurts, Nicolas; Goossens, Marijn; Schatterman, Peter; De Naeyer, Geert; Mottrie, Alexandre

    2017-04-01

    external validation at other high volume centers. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.