WorldWideScience

Sample records for high voltage generation

  1. High Voltage Seismic Generator

    Science.gov (United States)

    Bogacz, Adrian; Pala, Damian; Knafel, Marcin

    2015-04-01

    This contribution describes the preliminary result of annual cooperation of three student research groups from AGH UST in Krakow, Poland. The aim of this cooperation was to develop and construct a high voltage seismic wave generator. Constructed device uses a high-energy electrical discharge to generate seismic wave in ground. This type of device can be applied in several different methods of seismic measurement, but because of its limited power it is mainly dedicated for engineering geophysics. The source operates on a basic physical principles. The energy is stored in capacitor bank, which is charged by two stage low to high voltage converter. Stored energy is then released in very short time through high voltage thyristor in spark gap. The whole appliance is powered from li-ion battery and controlled by ATmega microcontroller. It is possible to construct larger and more powerful device. In this contribution the structure of device with technical specifications is resented. As a part of the investigation the prototype was built and series of experiments conducted. System parameter was measured, on this basis specification of elements for the final device were chosen. First stage of the project was successful. It was possible to efficiently generate seismic waves with constructed device. Then the field test was conducted. Spark gap wasplaced in shallowborehole(0.5 m) filled with salt water. Geophones were placed on the ground in straight line. The comparison of signal registered with hammer source and sparker source was made. The results of the test measurements are presented and discussed. Analysis of the collected data shows that characteristic of generated seismic signal is very promising, thus confirms possibility of practical application of the new high voltage generator. The biggest advantage of presented device after signal characteristics is its size which is 0.5 x 0.25 x 0.2 m and weight approximately 7 kg. This features with small li-ion battery makes

  2. Portable High Voltage Impulse Generator

    Directory of Open Access Journals (Sweden)

    S. Gómez

    2011-06-01

    Full Text Available This paper presents a portable high voltage impulse generator which was designed and built with insulation up to 20 kV. This design was based on previous work in which simulation software for standard waves was developed. Commercial components and low-cost components were used in this work; however, these particular elements are not generally used for high voltage applications. The impulse generators used in industry and laboratories are usually expensive; they are built to withstand extra high voltage and they are big, making them impossible to transport. The proposed generator is portable, thereby allowing tests to be made on devices that cannot be moved from their location. The results obtained with the proposed impulse generator were satisfactory in terms of time and waveforms compared to other commercial impulse generators and the standard impulse wave simulator.

  3. High Voltage Piezoelectric System for Generating Neutrons

    Science.gov (United States)

    2013-06-01

    10 mm × 1.5 mm -45-degree rotated y-cut lithium niobate slabs. Input electrodes, shown as gray regions on the top and bottom (not visible) surfaces on...the left portion of the bar in Fig. ??, were used to deliver electrical power to the crystal and applied using silver paint with a measured layer ...voltage, stress, and displacement. The crystals for the PTPS were disks of lithium niobate with 5 mm radius and 2 mm thickness, shown in Fig

  4. On-chip High-Voltage Generator Design

    CERN Document Server

    Tanzawa, Toru

    2013-01-01

    This book describes high-voltage generator design with switched-capacitor multiplier techniques.  The author provides various design techniques for switched-capacitor on-chip high-voltage generators, including charge pump circuits, regulators, level shifters, references, and oscillators.  Readers will see these techniques applied to system design in order to address the challenge of how the on-chip high-voltage generator is designed for Flash memories, LCD drivers, and other semiconductor devices to optimize the entire circuit area and power efficiency with a low voltage supply, while minimizing the cost.   ·         Shows readers how to design charge pump circuits with lower voltage operation, higher power efficiency, and smaller circuit area; ·         Describes comprehensive circuits and systems design of on-chip high-voltage generators; ·         Covers all the component circuit blocks, including charge pumps, pump regulators, level shifters, oscillators, and references.

  5. Ultra-compact Marx-type high-voltage generator

    Science.gov (United States)

    Goerz, David A.; Wilson, Michael J.

    2000-01-01

    An ultra-compact Marx-type high-voltage generator includes individual high-performance components that are closely coupled and integrated into an extremely compact assembly. In one embodiment, a repetitively-switched, ultra-compact Marx generator includes low-profile, annular-shaped, high-voltage, ceramic capacitors with contoured edges and coplanar extended electrodes used for primary energy storage; low-profile, low-inductance, high-voltage, pressurized gas switches with compact gas envelopes suitably designed to be integrated with the annular capacitors; feed-forward, high-voltage, ceramic capacitors attached across successive switch-capacitor-switch stages to couple the necessary energy forward to sufficiently overvoltage the spark gap of the next in-line switch; optimally shaped electrodes and insulator surfaces to reduce electric field stresses in the weakest regions where dissimilar materials meet, and to spread the fields more evenly throughout the dielectric materials, allowing them to operate closer to their intrinsic breakdown levels; and uses manufacturing and assembly methods to integrate the capacitors and switches into stages that can be arranged into a low-profile Marx generator.

  6. Spacecraft-generated plasma interaction with high voltage solar array

    Science.gov (United States)

    Parks, D. E.; Katz, I.

    1978-01-01

    Calculations are made of the effect of interactions of spacecraft-generated plasmas and high voltage solar array components on an advanced Solar Electric Propulsion system. The plasma consists of mercury ions and electrons resulting from the operation of ion thrusters and associated hollow cathode neutralizers. Because large areas of the solar array are at high potential and not completely insulated from the surrounding plasma, the array can, under some conditions, collect excessive electron currents. Results are given for the parasitic currents collected by the solar arrays and means for reducing these currents are considered.

  7. Design of Plasma Generator Driven by High-frequency High-voltage Power Supply

    OpenAIRE

    Yong-Nong, C.; K. Chih-Ming

    2013-01-01

    In this research, a high-frequency high-voltage power supply designed for plasma generator is presented. The power supply mainly consists of a series resonant converter with a high-frequency high-voltage boost transformer. Due to the indispensable high-voltage inheritance in the operation of plasma generator, the analysis of transformer need considering not only winding resistance, leakage inductance, magnetizing inductance, and core-loss resistance, but also parasitic capacitance resulted fr...

  8. Megahertz high voltage pulse generator suitable for capacitive load

    Science.gov (United States)

    Xu, Yu; Chen, Wei; Liang, Hao; Li, Yu-Huai; Liang, Fu-Tian; Shen, Qi; Liao, Sheng-Kai; Peng, Cheng-Zhi

    2017-11-01

    A high voltage pulse generator is presented to drive Pockels cell. The Pockels cell behaves like a capacitor which slows the rise/fall time of the pulse and restrains the repetition rate of the generator. To drive the Pockels cell applied in quantum communication system, it requires about 1 MHz repetition rate with the rise/fall time of the pulse less than 50 ns, adjustable amplitude up to 800 V and an adjustable duration. With the assistance of self-designed transformers, the circuits is simplified that a pair of high current radio frequency (RF) MOSFET drivers are employed to switch the power MOSFETs at a high speed, and the power MOSFETs shape the final output pulse with the requirements. From the tests, the generator can produce 800 V square pulses continously at 1 MHz rate with 46 ns in risetime and 31 ns in falltime when driving a 51 pF capacitive load. And the generator is now used to drive Pockels cell for encoding the polarization of photons.

  9. Megahertz high voltage pulse generator suitable for capacitive load

    Directory of Open Access Journals (Sweden)

    Yu Xu

    2017-11-01

    Full Text Available A high voltage pulse generator is presented to drive Pockels cell. The Pockels cell behaves like a capacitor which slows the rise/fall time of the pulse and restrains the repetition rate of the generator. To drive the Pockels cell applied in quantum communication system, it requires about 1 MHz repetition rate with the rise/fall time of the pulse less than 50 ns, adjustable amplitude up to 800 V and an adjustable duration. With the assistance of self-designed transformers, the circuits is simplified that a pair of high current radio frequency (RF MOSFET drivers are employed to switch the power MOSFETs at a high speed, and the power MOSFETs shape the final output pulse with the requirements. From the tests, the generator can produce 800 V square pulses continously at 1 MHz rate with 46 ns in risetime and 31 ns in falltime when driving a 51 pF capacitive load. And the generator is now used to drive Pockels cell for encoding the polarization of photons.

  10. 21 CFR 892.1700 - Diagnostic x-ray high voltage generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic x-ray high voltage generator. 892.1700... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1700 Diagnostic x-ray high voltage generator. (a) Identification. A diagnostic x-ray high voltage generator is a device that is intended to...

  11. Design of Plasma Generator Driven by High-frequency High-voltage Power Supply

    Directory of Open Access Journals (Sweden)

    C. Yong-Nong

    2013-04-01

    Full Text Available In this research, a high-frequency high-voltage power supply designed for plasma generator is presented. The power supply mainly consists of a series resonant converter with a high-frequency high-voltage boost transformer. Due to the indispensable high-voltage inheritance in the operation of plasma generator, the analysis of transformer need considering not only winding resistance, leakage inductance, magnetizing inductance, and core-loss resistance, but also parasitic capacitance resulted from the insulation wrappings on the high-voltage side. This research exhibits a simple approach to measuring equivalent circuit parameters of the high-frequency, high-voltage transformer with stray capacitance being introduced into the conventional modeling. The proposed modeling scheme provides not only a precise measurement procedure but also effective design information for series-load resonant converter. The plasma discharging plate is designed as part of the electric circuit in the series load-resonant converter and the circuit model of the plasma discharging plate is also conducted as well. Thus, the overall model of the high-voltage plasma generator is built and the designing procedures for appropriate selections of the corresponding resonant-circuit parameters can be established. Finally, a high-voltage plasma generator with 220V, 60Hz, and 1kW input, along with a 22 kHz and over 8kV output, is realized and implemented.

  12. Design of Plasma Generator Driven by High-frequency High-voltage Power Supply

    Directory of Open Access Journals (Sweden)

    C. Yong-Nong

    2013-03-01

    Full Text Available In this research, a high-frequency high-voltage power supply designed for plasma generator is presented. The powersupply mainly consists of a series resonant converter with a high-frequency high-voltage boost transformer. Due to theindispensable high-voltage inheritance in the operation of plasma generator, the analysis of transformer needconsidering not only winding resistance, leakage inductance, magnetizing inductance, and core-loss resistance, butalso parasitic capacitance resulted from the insulation wrappings on the high-voltage side. This research exhibits asimple approach to measuring equivalent circuit parameters of the high-frequency, high-voltage transformer with straycapacitance being introduced into the conventional modeling. The proposed modeling scheme provides not only aprecise measurement procedure but also effective design information for series-load resonant converter. The plasmadischarging plate is designed as part of the electric circuit in the series load-resonant converter and the circuit modelof the plasma discharging plate is also conducted as well. Thus, the overall model of the high-voltage plasmagenerator is built and the designing procedures for appropriate selections of the corresponding resonant-circuitparameters can be established. Finally, a high-voltage plasma generator with 220V, 60Hz, and 1kW input, along witha 22 kHz and over 8kV output, is realized and implemented.

  13. Design and Implementation of a High-Voltage Generator with Output Voltage Control for Vehicle ER Shock-Absorber Applications

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2013-01-01

    Full Text Available A self-oscillating high-voltage generator is proposed to supply voltage for a suspension system in order to control the damping force of an electrorheological (ER fluid shock absorber. By controlling the output voltage level of the generator, the damping force in the ER fluid shock absorber can be adjusted immediately. The shock absorber is part of the suspension system. The high-voltage generator drives a power transistor based on self-excited oscillation, which converts dc to ac. A high-frequency transformer with high turns ratio is used to increase the voltage. In addition, the system uses the car battery as dc power supply. By regulating the duty cycle of the main switch in the buck converter, the output voltage of the buck converter can be linearly adjusted so as to obtain a specific high voltage for ER. The driving system is self-excited; that is, no additional external driving circuit is required. Thus, it reduces cost and simplifies system structure. A prototype version of the actual product is studied to measure and evaluate the key waveforms. The feasibility of the proposed system is verified based on experimental results.

  14. Tesla’s high voltage and high frequency generators with oscillatory circuits

    OpenAIRE

    Cvetić Jovan M.

    2016-01-01

    The principles that represent the basics of the work of the high voltage and high frequency generator with oscillating circuits will be discussed. Until 1891, Tesla made and used mechanical generators with a large number of extruded poles for the frequencies up to about 20 kHz. The first electric generators based on a new principle of a weakly coupled oscillatory circuits he used for the wireless signal transmission, for the study of the discharges in vacuu...

  15. A high voltage asymmetric waveform generator for FAIMS.

    Science.gov (United States)

    Canterbury, Jesse D; Gladden, James; Buck, Lon; Olund, Roy; MacCoss, Michael J

    2010-07-01

    High field asymmetric waveform ion mobility spectrometry (FAIMS) has been used increasingly in recent years as an additional method of ion separation and selection before mass spectrometry. The FAIMS electrodes are relatively simple to design and fabricate for laboratories wishing to implement their own FAIMS designs. However, construction of the electronics apparatus needed to produce the required high magnitude asymmetric electric field oscillating at a frequency of several hundred kilohertz is not trivial. Here we present an entirely custom-built electronics setup capable of supplying the required waveforms and voltages. The apparatus is relatively simple and inexpensive to implement. We also present data acquired on this system demonstrating the use of FAIMS as a gas-phase ion filter interface to an ion trap mass spectrometer. Copyright 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.

  16. Simulation Model solves exact the Enigma named Generating high Voltages and high Frequencies by Tesla Coil

    Directory of Open Access Journals (Sweden)

    Simo Janjanin

    2016-11-01

    Full Text Available Simulation model of Tesla coil has been successfully completed, and has been verified the procedure and functioning. The literature and documentation for the model were taken from the rich sources, especially the copies of Tesla patents. The oscillating system‟s electrical scheme consists of the voltage supply 220/50 Hz, Fe transformer, capacitor and belonging chosen electrical components, the air gap in the primary Tesla coil (air transformer and spark gap in the exit of the coil. The investigation of the oscillating process Tesla coil‟s system using the simulation model in MATLAB & SIMULINK have given the exact solution the enigma named the generating high voltage and high frequency the Tesla‟s coil. The inductance voltage from the spark current in the primary (coil with its high voltage impulse excites the oscillating series circuit Ce-L3-R3 on the secondary of the air transformer to its own damped oscillations

  17. DEVELOPMENT OF HIGH-VOLTAGE HIGH-FREQUENCY POWER SUPPLY FOR OZONE GENERATION

    Directory of Open Access Journals (Sweden)

    NACERA HAMMADI

    2016-05-01

    Full Text Available A high-voltage high-frequency power supply for ozone generation is presented in this paper. Ozone generation is intended to be used in air and in water disinfection. A power stage consisting of a single-phase full bridge inverter for regulating the output power, a current push-pull inverter (driver and a control circuit are described and analyzed. This laboratory build power supply using a high voltage ferrite transformer and a PIC microcontroller was employed to energize a dielectric barrier discharge (DBD ozone generator. The inverter working on the basis of control strategy is of simple structure and has a variation range of the working frequency in order to obtain the optimal frequency value. The experimental results concerning electrical characterization and water treatment using a cylindrical DBD ozone generator supplied by this power supply are given in the end.

  18. Novel Interleaved Converter with Extra-High Voltage Gain to Process Low-Voltage Renewable-Energy Generation

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2016-10-01

    Full Text Available This paper presents a novel interleaved converter (NIC with extra-high voltage gain to process the power of low-voltage renewable-energy generators such as photovoltaic (PV panel, wind turbine, and fuel cells. The NIC can boost a low input voltage to a much higher voltage level to inject renewable energy to DC bus for grid applications. Since the NIC has two circuit branches in parallel at frond end to share input current, it is suitable for high power applications. In addition, the NIC is controlled in an interleaving pattern, which has the advantages that the NIC has lower input current ripple, and the frequency of the ripple is twice the switching frequency. Two coupled inductors and two switched capacitors are incorporated to achieve a much higher voltage gain than conventional high step-up converters. The proposed NIC has intrinsic features such as leakage energy totally recycling and low voltage stress on power semiconductor. Thorough theoretical analysis and key parameter design are presented in this paper. A prototype is built for practical measurements to validate the proposed NIC.

  19. Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through

    DEFF Research Database (Denmark)

    Wang, Yun; Wu, Qiuwei; Xu, Honghua

    2014-01-01

    (HVRT) capability of the DFIG WTGs. The characteristics of DFIG WTGs under voltage sags and swells were studied focusing on the DFIG WTG stator flux and rotor voltages during the transient periods of grid voltage changes. The protection schemes of the rotor crowbar circuit and the dc chopper circuit......This paper presents a fast coordinated control scheme of the rotor side converter (RSC), the DC chopper and the grid side converter (GSC) of doubly fed induction generator (DFIG) wind turbine generators (WTGs) which is to improve the low voltage ride through (LVRT) and high voltage ride through...... were proposed considering the characteristics of the DFIG WTGs during voltage changes. The fast coordinated control of RSC and GSC were developed based on the characteristic analysis in order to realize efficient LVRT and HVRT of the DFIG WTGs. The proposed fast coordinated control schemes were...

  20. Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through

    Directory of Open Access Journals (Sweden)

    Yun Wang

    2014-06-01

    Full Text Available This paper presents a fast coordinated control scheme of the rotor side converter (RSC, the Direct Current (DC chopper and the grid side converter (GSC of doubly fed induction generator (DFIG wind turbine generators (WTGs to improve the low voltage ride through (LVRT and high voltage ride through (HVRT capability of the DFIG WTGs. The characteristics of DFIG WTGs under voltage sags and swells were studied focusing on the DFIG WTG stator flux and rotor voltages during the transient periods of grid voltage changes. The protection schemes of the rotor crowbar circuit and the DC chopper circuit were proposed considering the characteristics of the DFIG WTGs during voltage changes. The fast coordinated control of RSC and GSC were developed based on the characteristic analysis in order to realize efficient LVRT and HVRT of the DFIG WTGs. The proposed fast coordinated control schemes were verified by time domain simulations using Matlab-Simulink.

  1. On-chip high-voltage generator design design methodology for charge pumps

    CERN Document Server

    Tanzawa, Toru

    2016-01-01

    This book provides various design techniques for switched-capacitor on-chip high-voltage generators, including charge pump circuits, regulators, level shifters, references, and oscillators.  Readers will see these techniques applied to system design in order to address the challenge of how the on-chip high-voltage generator is designed for Flash memories, LCD drivers, and other semiconductor devices to optimize the entire circuit area and power efficiency with a low voltage supply, while minimizing the cost.  This new edition includes a variety of useful updates, including coverage of power efficiency and comprehensive optimization methodologies for DC-DC voltage multipliers, modeling of extremely low voltage Dickson charge pumps, and modeling and optimum design of AC-DC switched-capacitor multipliers for energy harvesting and power transfer for RFID.

  2. High voltage pulse generators for kicker magnet excitation

    CERN Document Server

    Fiander, D C; Metzmacher, K D; Pearce, P

    1973-01-01

    Describes three new pulse generator systems for the excitation of the kicker magnets of fast ejection facilities. Firstly a pulse generator for the fast ejection from the 28 GeV proton synchrotron (CPS) of any desired number of the twenty circulating proton bunches is treated. Secondly the paper describes the development of a pulse generator for the transfer at 50 mu sec intervals of single bunches of the proton beam from the CPS to the new 300 GeV machine (SPS) in construction at CERN. Finally the development of a programmable eleven step pulse generator for the CPS/SPS transfer is described. This generator allows the shaving of the CPS beam during eleven turns, and because of the CPS/SPS diameter ratio, allows the SPS to be uniformly filled. (7 refs).

  3. Enhanced Local Grid Voltage Support Method for High Penetration of Distributed Generators

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Rodriguez, Pedro

    2011-01-01

    Grid voltage rise and thermal loading of network components are the most remarkable barriers to allow high number of distributed generator (DG) connections on the medium voltage (MV) and low voltage (LV) electricity networks. The other barriers such as grid power quality (harmonics, voltage...... unbalance, flicker etc.) and network protection mechanisms can be figured out once the maximum DG connection capacity of the network is reached. In this paper, additional reactive power reserve of inverter interfaced DGs is exploited to lower the grid voltage level by means of location-adaptive Q(U) droop...... function. The proposed method aims to achieve less grid voltage violations thus more DG connection on the electricity distribution networks can be allowed....

  4. Benchmarking of Voltage Sag Generators

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Zou, Zhixiang

    2012-01-01

    to guide these grid-connected distributed power generation systems. In order to verify the response of such systems for voltage disturbance, mainly for evaluation of voltage sags/dips, a Voltage Sag Generator (VSG) is needed. This paper evaluates such sag test devices according to IEC 61000 in order...... to provide cheaper solutions to test against voltage sags. Simulation and experimental results demonstrate that the shunt impedance based VSG solution is the easiest and cheapest one for laboratory test applications. The back-to-back fully controlled converter based VSG is the most flexible solution......The increased penetration of renewable energy systems, like photovoltaic and wind power systems, rises the concern about the power quality and stability of the utility grid. Some regulations for Low Voltage Ride-Through (LVRT) for medium voltage or high voltage applications, are coming into force...

  5. Development of a Marx-coupled trigger generator with high voltages and low time delay

    Science.gov (United States)

    Hu, Yixiang; Zeng, Jiangtao; Sun, Fengju; Cong, Peitian; Su, Zhaofeng; Yang, Shi; Zhang, Xinjun; Qiu, Ai'ci

    2016-10-01

    Coupled by the Marx of the "JianGuang-I" facility, a high voltage, low time-delay trigger generator was developed. Working principles of this trigger generator and its key issues were described in detail. Structures of this generator were also carefully designed and optimized. Based on the "JianGuang-I" Marx generator, a test stand was established. And a series of experiment tests were carried out to the study performance of this trigger generator. Experiment results show that the output voltage of this trigger generator can be continuously adjusted from 58 kV to 384 kV. The time delay (from the beginning of the Marx-discharging pulse to the time that the output pulse of the trigger generator arises) of this trigger pulse is about 200 ns and its peak time (0%˜100%) is less than 50 ns. Experiment results also indicate that the time-delay jitter of trigger voltages decreases rapidly with the increase in the peak voltage of trigger pulses. When the trigger voltage is higher than 250 kV, the time-delay jitters (the standard deviation) are less than 7.7 ns.

  6. High voltage engineering

    CERN Document Server

    Rizk, Farouk AM

    2014-01-01

    Inspired by a new revival of worldwide interest in extra-high-voltage (EHV) and ultra-high-voltage (UHV) transmission, High Voltage Engineering merges the latest research with the extensive experience of the best in the field to deliver a comprehensive treatment of electrical insulation systems for the next generation of utility engineers and electric power professionals. The book offers extensive coverage of the physical basis of high-voltage engineering, from insulation stress and strength to lightning attachment and protection and beyond. Presenting information critical to the design, selec

  7. High-voltage pulse generator with inductive energy storage and thyratron

    CERN Document Server

    Vereshchagin, N M

    2002-01-01

    The high-voltage pulse generator with the energy storage on the basis of the single layer solenoid with inductivity of 10-35 mu H is described. The TGI2-500/20 thyratron able of breaking reliably the current with the amplitude of 800-850 A was used as the current breaker. The voltage on the load is formed in two stages. The first stage is characterized by the voltage of 20-25 kV and the growth time of 150-200 m. At the second stage there takes place fast (approx 60 ns) formation of the voltage up 90 kV. The scheme of the charge quenching decreases the instability of the current breaker time

  8. Fast switching thyristor applied in nanosecond-pulse high-voltage generator with closed transformer core.

    Science.gov (United States)

    Li, Lee; Bao, Chaobing; Feng, Xibo; Liu, Yunlong; Fochan, Lin

    2013-02-01

    For a compact and reliable nanosecond-pulse high-voltage generator (NPHVG), the specification parameter selection and potential usage of fast controllable state-solid switches have an important bearing on the optimal design. The NPHVG with closed transformer core and fast switching thyristor (FST) was studied in this paper. According to the analysis of T-type circuit, the expressions for the voltages and currents of the primary and secondary windings on the transformer core of NPHVG were deduced, and the theoretical maximum analysis was performed. For NPHVG, the rise-rate of turn-on current (di/dt) across a FST may exceed its transient rating. Both mean and maximum values of di/dt were determined by the leakage inductances of the transformer, and the difference is 1.57 times. The optimum winding ratio is helpful to getting higher voltage output with lower specification FST, especially when the primary and secondary capacitances have been established. The oscillation period analysis can be effectively used to estimate the equivalent leakage inductance. When the core saturation effect was considered, the maximum di/dt estimated from the oscillating period of the primary current is more accurate than one from the oscillating period of the secondary voltage. Although increasing the leakage inductance of NPHVG can decrease di/dt across FST, it may reduce the output peak voltage of the NPHVG.

  9. High voltage engineering fundamentals

    CERN Document Server

    Kuffel, E; Hammond, P

    1984-01-01

    Provides a comprehensive treatment of high voltage engineering fundamentals at the introductory and intermediate levels. It covers: techniques used for generation and measurement of high direct, alternating and surge voltages for general application in industrial testing and selected special examples found in basic research; analytical and numerical calculation of electrostatic fields in simple practical insulation system; basic ionisation and decay processes in gases and breakdown mechanisms of gaseous, liquid and solid dielectrics; partial discharges and modern discharge detectors; and over

  10. Tesla’s high voltage and high frequency generators with oscillatory circuits

    Directory of Open Access Journals (Sweden)

    Cvetić Jovan M.

    2016-01-01

    Full Text Available The principles that represent the basics of the work of the high voltage and high frequency generator with oscillating circuits will be discussed. Until 1891, Tesla made and used mechanical generators with a large number of extruded poles for the frequencies up to about 20 kHz. The first electric generators based on a new principle of a weakly coupled oscillatory circuits he used for the wireless signal transmission, for the study of the discharges in vacuum tubes, the wireless energy transmission, for the production of the cathode rays, that is x-rays and other experiments. Aiming to transfer the signals and the energy to any point of the surface of the Earth, in the late of 19th century, he had discovered and later patented a new type of high frequency generator called a magnifying transmitter. He used it to examine the propagation of electromagnetic waves over the surface of the Earth in experiments in Colorado Springs in the period 1899-1900. Tesla observed the formation of standing electromagnetic waves on the surface of the Earth by measuring radiated electric field from distant lightning thunderstorm. He got the idea to generate the similar radiation to produce the standing waves. On the one hand, signal transmission, i.e. communication at great distances would be possible and on the other hand, with more powerful and with at least three magnifying transmitters the wireless transmission of energy without conductors at any point of the Earth surface could also be achieved. The discovery of the standing waves on the surface of the Earth and the invention of the magnifying transmitter he claimed his greatest inventions. Less than two years later, at the end of 1901, he designed and started to build a much stronger magnifying transmitter on Long Island near New York City (the Wardenclyffe tower wishing to become a world telecommunication center. During the tower construction, he elaborated the plans for an even stronger transmitter based on

  11. Design of a high DC voltage generator and D-T fuser based on particle accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Wagner L.; Campos, Tarcisio P.R., E-mail: wagnerleite@ufmg.b, E-mail: campos@nuclear.ufmg.b [Universidade Federal de Minas Gerais (DEN/ UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear

    2011-07-01

    This paper approaches a design and simulation of a high voltage Cockcroft Walton multiplier and a compact size deuteron accelerator addressed in neutron generation by d-t fusion. We proposed a circuit arrangement, which was led to simulations. The particle accelerator was computer-generated providing particle transport and electric potential analysis. As results, the simulated voltage multiplier achieved 119 kV, and the accelerator presented a deuteron beam current up to 15 mA, achieving energies in order to 100 keV. In conclusion, the simulation motivates experimental essays in order to investigate the viability of a deuteron accelerator powered by a Cockcroft-Walton source. Such d-t fusor shall produce an interesting ion beam profile, reaching energy values near the d-t fusion cross section peak. (author)

  12. A compact high-voltage pulse generator based on pulse transformer with closed magnetic core.

    Science.gov (United States)

    Zhang, Yu; Liu, Jinliang; Cheng, Xinbing; Bai, Guoqiang; Zhang, Hongbo; Feng, Jiahuai; Liang, Bo

    2010-03-01

    A compact high-voltage nanosecond pulse generator, based on a pulse transformer with a closed magnetic core, is presented in this paper. The pulse generator consists of a miniaturized pulse transformer, a curled parallel strip pulse forming line (PFL), a spark gap, and a matched load. The innovative design is characterized by the compact structure of the transformer and the curled strip PFL. A new structure of transformer windings was designed to keep good insulation and decrease distributed capacitance between turns of windings. A three-copper-strip structure was adopted to avoid asymmetric coupling of the curled strip PFL. When the 31 microF primary capacitor is charged to 2 kV, the pulse transformer can charge the PFL to 165 kV, and the 3.5 ohm matched load can deliver a high-voltage pulse with a duration of 9 ns, amplitude of 84 kV, and rise time of 5.1 ns. When the load is changed to 50 ohms, the output peak voltage of the generator can be 165 kV, the full width at half maximum is 68 ns, and the rise time is 6.5 ns.

  13. A High-Efficiency Voltage Equalization Scheme for Supercapacitor Energy Storage System in Renewable Generation Applications

    Directory of Open Access Journals (Sweden)

    Liran Li

    2016-06-01

    Full Text Available Due to its fast charge and discharge rate, a supercapacitor-based energy storage system is especially suitable for power smoothing in renewable energy generation applications. Voltage equalization is essential for series-connected supercapacitors in an energy storage system, because it supports the system’s sustainability and maximizes the available cell energy. In this paper, we present a high-efficiency voltage equalization scheme for supercapacitor energy storage systems in renewable generation applications. We propose an improved isolated converter topology that uses a multi-winding transformer. An improved push-pull forward circuit is applied on the primary side of the transformer. A coupling inductor is added on the primary side to allow the switches to operate under the zero-voltage switching (ZVS condition, which reduces switching losses. The diodes in the rectifier are replaced with metal-oxide-semiconductor field-effect transistors (MOSFETs to reduce the power dissipation of the secondary side. In order to simplify the control, we designed a controllable rectifying circuit to achieve synchronous rectifying on the secondary side of the transformer. The experimental results verified the effectiveness of the proposed design.

  14. A 70 kV solid-state high voltage pulse generator based on saturable pulse transformer.

    Science.gov (United States)

    Fan, Xuliang; Liu, Jinliang

    2014-02-01

    High voltage pulse generators are widely applied in many fields. In recent years, solid-state and operating at repetitive mode are the most important developing trends of high voltage pulse generators. A solid-state high voltage pulse generator based on saturable pulse transformer is proposed in this paper. The proposed generator is consisted of three parts. They are charging system, triggering system, and the major loop. Saturable pulse transformer is the key component of the whole generator, which acts as a step-up transformer and main switch during working process of this generator. The circuit and working principles of the proposed pulse generator are introduced first in this paper, and the saturable pulse transformer used in this generator is introduced in detail. Circuit of the major loop is simulated to verify the design of the system. Demonstration experiments are carried out, and the results show that when the primary energy storage capacitor is charged to a high voltage, such as 2.5 kV, a voltage with amplitude of 86 kV can be achieved on the secondary winding. The magnetic core of saturable pulse transformer is saturated deeply and the saturable inductance of the secondary windings is very small. The switch function of the saturable pulse transformer can be realized ideally. Therefore, a 71 kV output voltage pulse is formed on the load. Moreover, the magnetic core of the saturable pulse transformer can be reset automatically.

  15. MOSFET-based high voltage double square-wave pulse generator with an inductive adder configuration

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Xin [State Key Laboratory of Electrical Insulation and Power Equipment, Xi' an Jiaotong University, Xi' an 710049 (China); Zhang, Qiaogen, E-mail: hvzhang@mail.xjtu.edu.cn [State Key Laboratory of Electrical Insulation and Power Equipment, Xi' an Jiaotong University, Xi' an 710049 (China); Long, Jinghua [College of Physics, Shenzhen University, Shenzhen 518060 (China); Lei, Yunfei; Liu, Jinyuan [Institute of Optoelectronics, Shenzhen University, Shenzhen 518060 (China)

    2015-09-01

    This paper presents a fast MOSFET-based solid-state pulse generator for high voltage double square-wave pulses. The generator consists mainly of an inductive adder system stacked of 20 solid-state modules. Each of the modules has 18 power MOSFETs in parallel, which are triggered by individual drive circuits; these drive circuits themselves are synchronously triggered by a signal from avalanche transistors. Our experiments demonstrate that the output pulses with amplitude of 8.1 kV and peak current of about 405 A are available at a load impedance of 20 Ω. The pulse has a double square-wave form with a rise and fall time of 40 ns and 26 ns, respectively and bottom flatness better than 12%. The interval time of the double square-wave pulses can be adjustable by varying the interval time of the trigger pulses.

  16. A high voltage pulse generator based on silicon-controlled rectifier for field-reversed configuration experiment

    Science.gov (United States)

    Lin, Munan; Liu, Ming; Zhu, Guanghui; Wang, Yanpeng; Shi, Peiyun; Sun, Xuan

    2017-08-01

    A high voltage pulse generator based on a silicon-controlled rectifier has been designed and implemented for a field reversed configuration experiment. A critical damping circuit is used in the generator to produce the desired pulse waveform. Depending on the load, the rise time of the output trigger signal can be less than 1 μs, and the peak amplitudes of trigger voltage and current are up to 8 kV and 85 A in a single output. The output voltage can be easily adjusted by changing the voltage on a capacitor of the generator. In addition, the generator integrates an electrically floating heater circuit so it is capable of triggering either pseudosparks (TDI-type hydrogen thyratron) or ignitrons. Details of the circuits and their implementation are described in the paper. The trigger generator has successfully controlled the discharging sequence of the pulsed power supply for a field reversed configuration experiment.

  17. Dynamic voltage stability of a distribution system with high penetration of grid-connected photovoltaic type solar generators

    Directory of Open Access Journals (Sweden)

    Zetty Adibah Kamaruzzaman

    2016-06-01

    Full Text Available This paper presents the impact of grid-connected photovoltaic (PV generator on dynamic voltage stability of a power distribution system by considering solar intermittency, PV penetration level, and contingencies such as line outage and load increase. The IEEE 13 node test feeder is used as a test system, and a solar PV of 0.48 kV/0.5 MVA is integrated into the test system. Test results show that system voltage is stable at high PV penetration levels. Increase in load causes voltage instability, in which voltage drops below its allowable operating limit. Thus, increase in PV penetration level does not improve system voltage stability because the system experiences voltage collapse during line outage.

  18. Dual branch high voltage pulse generator for the beam extraction of the Large Hadron Collider

    CERN Document Server

    Bonthond, J; Ducimetière, L; Jansson, U; Vossenberg, Eugène B

    2002-01-01

    The LHC beam extraction kicker system, MKD, is composed of 15 fast kicker magnets per beam to extract the particles in one turn from the collider and to dispose them, after dilution, on an external absorber. Each magnet is powered by a separate pulse generator. The original single branch generator consisted of a discharge capacitor in series with a solid state closing switch left bracket 1 right bracket operating at 30 kV. In combination with a parallel freewheel diode stack this generator produced a current pulse of 2.7 mus rise time, 18.5 kA amplitude and about 1.8 ms fall time, of which only about 90 mus are needed to dump the beam. The freewheel diode circuit is equipped with a flat top current droop compensation network, consisting of a low voltage, low stray inductance, high current discharge capacitor. Extensive reliability studies have meanwhile suggested to further increase the operational safety of this crucial system by equipping each generator with two parallel branches. This paper presents the re...

  19. Simulation Model solves exact the Enigma named Generating high Voltages and high Frequencies by Tesla Coil

    OpenAIRE

    Simo Janjanin

    2016-01-01

    Simulation model of Tesla coil has been successfully completed, and has been verified the procedure and functioning. The literature and documentation for the model were taken from the rich sources, especially the copies of Tesla patents. The oscillating system‟s electrical scheme consists of the voltage supply 220/50 Hz, Fe transformer, capacitor and belonging chosen electrical components, the air gap in the primary Tesla coil (air transformer) and spark gap in the exit of the coil. The inves...

  20. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  1. Technological Aspects: High Voltage

    CERN Document Server

    Faircloth, D.C.

    2013-12-16

    This paper covers the theory and technological aspects of high-voltage design for ion sources. Electric field strengths are critical to understanding high-voltage breakdown. The equations governing electric fields and the techniques to solve them are discussed. The fundamental physics of high-voltage breakdown and electrical discharges are outlined. Different types of electrical discharges are catalogued and their behaviour in environments ranging from air to vacuum are detailed. The importance of surfaces is discussed. The principles of designing electrodes and insulators are introduced. The use of high-voltage platforms and their relation to system design are discussed. The use of commercially available high-voltage technology such as connectors, feedthroughs and cables are considered. Different power supply technologies and their procurement are briefly outlined. High-voltage safety, electric shocks and system design rules are covered.

  2. Push-pull with recovery stage high-voltage DC converter for PV solar generator

    Science.gov (United States)

    Nguyen, The Vinh; Aillerie, Michel; Petit, Pierre; Pham, Hong Thang; Vo, Thành Vinh

    2017-02-01

    A lot of systems are basically developed on DC-DC or DC-AC converters including electronic switches such as MOS or bipolar transistors. The limits of efficiency are quickly reached when high output voltages and high input currents are needed. This work presents a new high-efficiency-high-step-up based on push-pull DC-DC converter integrating recovery stages dedicated to smart HVDC distributed architecture in PV solar energy production systems. Appropriate duty cycle ratio assumes that the recovery stage work with parallel charge and discharge to achieve high step-up voltage gain. Besides, the voltage stress on the main switch is reduced with a passive clamp circuit and thus, low on-state resistance Rdson of the main switch can be adopted to reduce conduction losses. Thus, the efficiency of a basic DC-HVDC converter dedicated to renewable energy production can be further improved with such topology. A prototype converter is developed, and experimentally tested for validation.

  3. High voltage test techniques

    CERN Document Server

    Kind, Dieter

    2001-01-01

    The second edition of High Voltage Test Techniques has been completely revised. The present revision takes into account the latest international developments in High Voltage and Measurement technology, making it an essential reference for engineers in the testing field.High Voltage Technology belongs to the traditional area of Electrical Engineering. However, this is not to say that the area has stood still. New insulating materials, computing methods and voltage levels repeatedly pose new problems or open up methods of solution; electromagnetic compatibility (EMC) or components and systems al

  4. Voltage management of distribution networks with high penetration of distributed photovoltaic generation sources

    Science.gov (United States)

    Alyami, Saeed

    Installation of photovoltaic (PV) units could lead to great challenges to the existing electrical systems. Issues such as voltage rise, protection coordination, islanding detection, harmonics, increased or changed short-circuit levels, etc., need to be carefully addressed before we can see a wide adoption of this environmentally friendly technology. Voltage rise or overvoltage issues are of particular importance to be addressed for deploying more PV systems to distribution networks. This dissertation proposes a comprehensive solution to deal with the voltage violations in distribution networks, from controlling PV power outputs and electricity consumption of smart appliances in real time to optimal placement of PVs at the planning stage. The dissertation is composed of three parts: the literature review, the work that has already been done and the future research tasks. An overview on renewable energy generation and its challenges are given in Chapter 1. The overall literature survey, motivation and the scope of study are also outlined in the chapter. Detailed literature reviews are given in the rest of chapters. The overvoltage and undervoltage phenomena in typical distribution networks with integration of PVs are further explained in Chapter 2. Possible approaches for voltage quality control are also discussed in this chapter, followed by the discussion on the importance of the load management for PHEVs and appliances and its benefits to electric utilities and end users. A new real power capping method is presented in Chapter 3 to prevent overvoltage by adaptively setting the power caps for PV inverters in real time. The proposed method can maintain voltage profiles below a pre-set upper limit while maximizing the PV generation and fairly distributing the real power curtailments among all the PV systems in the network. As a result, each of the PV systems in the network has equal opportunity to generate electricity and shares the responsibility of voltage

  5. A Simple MPPT Algorithm for Novel PV Power Generation System by High Output Voltage DC-DC Boost Converter

    DEFF Research Database (Denmark)

    Sanjeevikumar, Padmanaban; Grandi, Gabriele; Wheeler, Patrick

    2015-01-01

    substantially improves the high output-voltage by a simple MPPT closed loop proportional-integral (P-I) controller, and requires only two sensor for feedback needs. The complete numerical model of the converter circuit along with PV MPPT algorithm is developed in numerical simulation (Matlab/Simulink) software......This paper presents the novel topology of Photo Voltaic (PV) power generation system with simple Maximum Power Point Tracking (MPPT) algorithm in voltage operating mode. Power circuit consists of high output voltage DC-DC boost converter which maximizes the output of PV panel. Usually traditional...... DC-DC boost converters are used for such application, but they are not the most suitable solution due to output limitation, lower efficiency and require more sensors with complex control algorithm. Further on, the effects of parasitic elements are suppressed, as well as the power transfer efficiency...

  6. Novel design of high voltage pulse source for efficient dielectric barrier discharge generation by using silicon diodes for alternating current.

    Science.gov (United States)

    Truong, Hoa Thi; Hayashi, Misaki; Uesugi, Yoshihiko; Tanaka, Yasunori; Ishijima, Tatsuo

    2017-06-01

    This work focuses on design, construction, and optimization of configuration of a novel high voltage pulse power source for large-scale dielectric barrier discharge (DBD) generation. The pulses were generated by using the high-speed switching characteristic of an inexpensive device called silicon diodes for alternating current and the self-terminated characteristic of DBD. The operation started to be powered by a primary DC low voltage power supply flexibly equipped with a commercial DC power supply, or a battery, or DC output of an independent photovoltaic system without transformer employment. This flexible connection to different types of primary power supply could provide a promising solution for the application of DBD, especially in the area without power grid connection. The simple modular structure, non-control requirement, transformer elimination, and a minimum number of levels in voltage conversion could lead to a reduction in size, weight, simple maintenance, low cost of installation, and high scalability of a DBD generator. The performance of this pulse source has been validated by a load of resistor. A good agreement between theoretically estimated and experimentally measured responses has been achieved. The pulse source has also been successfully applied for an efficient DBD plasma generation.

  7. Novel design of high voltage pulse source for efficient dielectric barrier discharge generation by using silicon diodes for alternating current

    Science.gov (United States)

    Truong, Hoa Thi; Hayashi, Misaki; Uesugi, Yoshihiko; Tanaka, Yasunori; Ishijima, Tatsuo

    2017-06-01

    This work focuses on design, construction, and optimization of configuration of a novel high voltage pulse power source for large-scale dielectric barrier discharge (DBD) generation. The pulses were generated by using the high-speed switching characteristic of an inexpensive device called silicon diodes for alternating current and the self-terminated characteristic of DBD. The operation started to be powered by a primary DC low voltage power supply flexibly equipped with a commercial DC power supply, or a battery, or DC output of an independent photovoltaic system without transformer employment. This flexible connection to different types of primary power supply could provide a promising solution for the application of DBD, especially in the area without power grid connection. The simple modular structure, non-control requirement, transformer elimination, and a minimum number of levels in voltage conversion could lead to a reduction in size, weight, simple maintenance, low cost of installation, and high scalability of a DBD generator. The performance of this pulse source has been validated by a load of resistor. A good agreement between theoretically estimated and experimentally measured responses has been achieved. The pulse source has also been successfully applied for an efficient DBD plasma generation.

  8. VOLTAGE REGULATORS OF SYNCHRONOUS GENERATORS

    OpenAIRE

    Grigorash O. V.; Korzenkov P. G.; Popuchieva M. A.

    2015-01-01

    Synchronous generators are the primary source of electrical power autonomous electrosupply systems, including backup systems. They are also used in a structure of rotating electricity converters and are widely used in renewable energy as part of wind power plants of small, mini and micro hydroelectric plants. Increasing the speed and the accuracy of the system of the voltage regulation of synchronous generators is possible due to the development of combined systems containing more stabilizers...

  9. Gyromagnetic nonlinear transmission line generator of high voltage pulses modulated at 4 GHz frequency with 1000 Hz pulse repetition rate

    Science.gov (United States)

    Ulmasculov, M. R.; Sharypov, K. A.; Shunailov, S. A.; Shpak, V. G.; Yalandin, M. I.; Pedos, M. S.; Rukin, S. N.

    2017-05-01

    Results of testing of a generator based on a solid-state drive and the parallel gyromagnetic nonlinear transmission lines with external bias are presented. Stable rf-modulated high-voltage nanosecond pulses were shaped in each of the four channels in 1 s packets with 1000 Hz repetition frequencies. Pulse amplitude reaches -175 kV, at a modulation depth of rf-oscillations to 50 % and the effective frequency ∼4 GHz.

  10. PV Power-Generation System with a Phase-Shift PWM Technique for High Step-Up Voltage Applications

    Directory of Open Access Journals (Sweden)

    Cheng-Tao Tsai

    2012-01-01

    Full Text Available A PV power-generation system with a phase-shift pulse-width modulation (PWM technique for high step-up voltage applications is proposed. The proposed power-generation system consists of two stages. In the input stage, all power switches of the full-bridge converter with phase-shift technique can be operated with zero-current switching (ZCS at turn-on or turn-off transition. Hence, the switching losses of the power switches can be reduced. Then, in the DC output stage, a voltage-doubler circuit is used to boost a high dc-link bus voltage. To supply a utility power, a dc/ac inverter is connected to induce a sinusoidal source. In order to draw a maximum power from PV arrays source, a microcontroller is incorporated with the perturbation and observation method to implement maximum power point tracking (MPPT algorithm and power regulating scheme. In this study, a full load power of 300 W prototype has been built. Experimental results are presented to verify the performance and feasibility of the proposed PV power-generation system.

  11. Hydrodynamic modelling of transient cavities in fluids generated by high voltage spark discharges

    Energy Technology Data Exchange (ETDEWEB)

    Timoshkin, I V; Fouracre, R A; Given, M J; MacGregor, S J [HVT Research Group, Institute for Energy and Environment, Department of Electronic and Electrical Engineering, University of Strathclyde, Royal College Building, 204 George St, Glasgow, G1 1XW (United Kingdom)

    2006-11-21

    Application of a voltage pulse having a rise time of tens of nanoseconds to electrodes immersed in water results in streamer development and the formation of a highly conductive plasma channel between the electrodes. The electrical resistance of such channels decreases rapidly from a few ohms to a few tens of milliohms due to Joule heating resulting from the high current which flows through the plasma. The dynamics of the plasma resistance depend on the parameters of the discharge circuit and the medium in which the discharge takes place. The resistance of the channel reaches a minimum value approximately at the moment of the peak current for under-damped current oscillations. During the resistance collapse, the pressure inside the channel rises to several GPa, causing a rapid expansion of the channel which forms a cavity in the liquid resulting in a high power ultrasound pulse. The cavity expands to a maximum size which is dependent on the circuit driving the discharge and the properties of the plasma discharge channel. The cavity then collapses producing a second acoustic pulse. In this paper the dynamic resistance of the spark channel is described using a phenomenological model based on the plasma channel energy balance equation used by Braginskii. The model which links the hydrodynamic characteristics of the channel and the resulting cavity with the parameters of the electric driving circuit allows the development of the plasma channel and cavity to be predicted. The peak high-power ultrasound (HPU) pressures calculated using this approach are compared with the pressure values estimated by an analytical model which uses a constant value of the spark channel resistance derived from experimental data. Comparisons are also made with direct measurements of HPU output made using a Pinducer sensor. Although the model is based on a phenomenological description of the plasma channel dynamics and its resistance and requires the value of the spark constant, the results

  12. Hydrodynamic modelling of transient cavities in fluids generated by high voltage spark discharges

    Science.gov (United States)

    Timoshkin, I. V.; Fouracre, R. A.; Given, M. J.; MacGregor, S. J.

    2006-11-01

    Application of a voltage pulse having a rise time of tens of nanoseconds to electrodes immersed in water results in streamer development and the formation of a highly conductive plasma channel between the electrodes. The electrical resistance of such channels decreases rapidly from a few ohms to a few tens of milliohms due to Joule heating resulting from the high current which flows through the plasma. The dynamics of the plasma resistance depend on the parameters of the discharge circuit and the medium in which the discharge takes place. The resistance of the channel reaches a minimum value approximately at the moment of the peak current for under-damped current oscillations. During the resistance collapse, the pressure inside the channel rises to several GPa, causing a rapid expansion of the channel which forms a cavity in the liquid resulting in a high power ultrasound pulse. The cavity expands to a maximum size which is dependent on the circuit driving the discharge and the properties of the plasma discharge channel. The cavity then collapses producing a second acoustic pulse. In this paper the dynamic resistance of the spark channel is described using a phenomenological model based on the plasma channel energy balance equation used by Braginskii. The model which links the hydrodynamic characteristics of the channel and the resulting cavity with the parameters of the electric driving circuit allows the development of the plasma channel and cavity to be predicted. The peak high-power ultrasound (HPU) pressures calculated using this approach are compared with the pressure values estimated by an analytical model which uses a constant value of the spark channel resistance derived from experimental data. Comparisons are also made with direct measurements of HPU output made using a Pinducer sensor. Although the model is based on a phenomenological description of the plasma channel dynamics and its resistance and requires the value of the spark constant, the results

  13. High voltage generation from lead-free magnetoelectric coaxial nanotube arrays and their applications in nano energy harvesters

    Science.gov (United States)

    Lekha, C. S. Chitra; Kumar, Ajith S.; Vivek, S.; Rasi, U. P. Mohammed; Venkata Saravanan, K.; Nandakumar, K.; Nair, Swapna S.

    2017-02-01

    Harvesting energy from surrounding vibrations and developing self-powered portable devices for wireless and mobile electronics have recently become popular. Here the authors demonstrate the synthesis of piezoelectric energy harvesters based on nanotube arrays by a wet chemical route, which requires no sophisticated instruments. The energy harvester gives an output voltage of 400 mV. Harvesting energy from a sinusoidal magnetic field is another interesting phenomenon for which the authors fabricated a magnetoelectric energy harvester based on piezoelectric-magnetostrictive coaxial nanotube arrays. Piezoelectric K0.5Na0.5NbO3 (KNN) is fabricated as the shell and magnetostrictive CoFe2O4 (CFO) as the core of the composite coaxial nanotubes. The delivered voltages are as high as 300 mV at 500 Hz and at a weak ac magnetic field of 100 Oe. Further tailoring of the thickness of the piezoelectric and magnetic layers can enhance the output voltage by several orders. Easy, single-step wet chemical synthesis enhances the industrial upscaling potential of these nanotubes as energy harvesters. In view of the excellent properties reported here, the lead-free piezoelectric component (KNN) in this nanocomposite should be explored for eco-friendly piezoelectric as well as magnetoelectric power generators in nanoelectromechanical systems (NEMS).

  14. An exploding foil shockwave technique for magnetic flux compression and high voltage pulse generation

    CERN Document Server

    Goh, S E

    2002-01-01

    This thesis describes a novel electromagnetic shockwave technique for use in compressing magnetic flux and to serve as the basis for a new approach to producing fast-rising voltage pulses with amplitudes of several hundred kV. The shockwave is produced by an exploding foil driven electric gun that accelerates a Mylar flyer to impact with a sample of aluminium powder. Both Japanese and Russian researchers have previously published experimental results for shockwave magnetic flux compression using an explosive driver. The present research considers replacing the explosive energy of this driver by the electrostatic energy stored in a capacitor bank, thereby enabling experiments to be performed in a laboratory environment. Differences in performance that arise from the use of explosive and electrical driver are examined. A conventional electric gun system in planar geometry is developed to study the insulator-to-metallic transition in shock-compressed aluminium powder. This provides data on the conducting shock f...

  15. Operation Manual of the high voltage generator of the Pelletron electron accelerator; Manual de operacion del generador de alto voltaje del acelerador de electrones Pelletron

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez M, V.; Lopez V, H.; Alba P, U

    1988-04-15

    The first version of a manual to operate the generator of high voltage generator of the Pelletron electron accelerator built in the ININ is presented. Since this generator has several components and/or elements, the one manual present has the purpose that the armed one or maintenance of anyone on its parts, is carried out in an orderly and efficient way. (Author)

  16. A distributed parameter model of transmission line transformer for high voltage nanosecond pulse generation.

    Science.gov (United States)

    Li, Jiangtao; Zhao, Zheng; Li, Longjie; He, Jiaxin; Li, Chenjie; Wang, Yifeng; Su, Can

    2017-09-01

    A transmission line transformer has potential advantages for nanosecond pulse generation including excellent frequency response and no leakage inductance. The wave propagation process in a secondary mode line is indispensable due to an obvious inside transient electromagnetic transition in this scenario. The equivalent model of the transmission line transformer is crucial for predicting the output waveform and evaluating the effects of magnetic cores on output performance. However, traditional lumped parameter models are not sufficient for nanosecond pulse generation due to the natural neglect of wave propagations in secondary mode lines based on a lumped parameter assumption. In this paper, a distributed parameter model of transmission line transformer was established to investigate wave propagation in the secondary mode line and its influential factors through theoretical analysis and experimental verification. The wave propagation discontinuity in the secondary mode line induced by magnetic cores is emphasized. Characteristics of the magnetic core under a nanosecond pulse were obtained by experiments. Distribution and formation of the secondary mode current were determined for revealing essential wave propagation processes in secondary mode lines. The output waveform and efficiency were found to be affected dramatically by wave propagation discontinuity in secondary mode lines induced by magnetic cores. The proposed distributed parameter model was proved more suitable for nanosecond pulse generation in aspects of secondary mode current, output efficiency, and output waveform. In depth, comprehension of underlying mechanisms and a broader view of the working principle of the transmission line transformer for nanosecond pulse generation can be obtained through this research.

  17. A distributed parameter model of transmission line transformer for high voltage nanosecond pulse generation

    Science.gov (United States)

    Li, Jiangtao; Zhao, Zheng; Li, Longjie; He, Jiaxin; Li, Chenjie; Wang, Yifeng; Su, Can

    2017-09-01

    A transmission line transformer has potential advantages for nanosecond pulse generation including excellent frequency response and no leakage inductance. The wave propagation process in a secondary mode line is indispensable due to an obvious inside transient electromagnetic transition in this scenario. The equivalent model of the transmission line transformer is crucial for predicting the output waveform and evaluating the effects of magnetic cores on output performance. However, traditional lumped parameter models are not sufficient for nanosecond pulse generation due to the natural neglect of wave propagations in secondary mode lines based on a lumped parameter assumption. In this paper, a distributed parameter model of transmission line transformer was established to investigate wave propagation in the secondary mode line and its influential factors through theoretical analysis and experimental verification. The wave propagation discontinuity in the secondary mode line induced by magnetic cores is emphasized. Characteristics of the magnetic core under a nanosecond pulse were obtained by experiments. Distribution and formation of the secondary mode current were determined for revealing essential wave propagation processes in secondary mode lines. The output waveform and efficiency were found to be affected dramatically by wave propagation discontinuity in secondary mode lines induced by magnetic cores. The proposed distributed parameter model was proved more suitable for nanosecond pulse generation in aspects of secondary mode current, output efficiency, and output waveform. In depth, comprehension of underlying mechanisms and a broader view of the working principle of the transmission line transformer for nanosecond pulse generation can be obtained through this research.

  18. High voltage variable diameter insulator

    Science.gov (United States)

    Vanecek, David L.; Pike, Chester D.

    1984-01-01

    A high voltage feedthrough assembly (10) having a tubular insulator (15) extending between the ground plane ring (16) and the high voltage ring (30). The insulator (15) is made of Pyrex and decreases in diameter from the ground plane ring (16) to the high voltage ring (30), producing equipotential lines almost perpendicular to the wall (27) of the insulator (15) to optimize the voltage-holding capability of the feedthrough assembly (10).

  19. Nanosecond pulsed electric fields (nsPEFs) low cost generator design using power MOSFET and Cockcroft-Walton multiplier circuit as high voltage DC source

    Science.gov (United States)

    Sulaeman, M. Y.; Widita, R.

    2014-09-01

    Purpose: Non-ionizing radiation therapy for cancer using pulsed electric field with high intensity field has become an interesting field new research topic. A new method using nanosecond pulsed electric fields (nsPEFs) offers a novel means to treat cancer. Not like the conventional electroporation, nsPEFs able to create nanopores in all membranes of the cell, including membrane in cell organelles, like mitochondria and nucleus. NsPEFs will promote cell death in several cell types, including cancer cell by apoptosis mechanism. NsPEFs will use pulse with intensity of electric field higher than conventional electroporation, between 20-100 kV/cm and with shorter duration of pulse than conventional electroporation. NsPEFs requires a generator to produce high voltage pulse and to achieve high intensity electric field with proper pulse width. However, manufacturing cost for creating generator that generates a high voltage with short duration for nsPEFs purposes is highly expensive. Hence, the aim of this research is to obtain the low cost generator design that is able to produce a high voltage pulse with nanosecond width and will be used for nsPEFs purposes. Method: Cockcroft-Walton multiplier circuit will boost the input of 220 volt AC into high voltage DC around 1500 volt and it will be combined by a series of power MOSFET as a fast switch to obtain a high voltage with nanosecond pulse width. The motivation using Cockcroft-Walton multiplier is to acquire a low-cost high voltage DC generator; it will use capacitors and diodes arranged like a step. Power MOSFET connected in series is used as voltage divider to share the high voltage in order not to damage them. Results: This design is expected to acquire a low-cost generator that can achieve the high voltage pulse in amount of -1.5 kV with falltime 3 ns and risetime 15 ns into a 50Ω load that will be used for nsPEFs purposes. Further detailed on the circuit design will be explained at presentation.

  20. Evaluation of the contact switch materials in high voltage power supply for generate of underwater shockwave by electrical discharge

    Directory of Open Access Journals (Sweden)

    K Higa

    2016-10-01

    Full Text Available We have developed the high voltage power-supply unit by Cockcroft-Walton circuit for ingenerate high pressure due to underwater shockwave by electrical discharge. This high voltage power supply has the problem of the metal contact switch operation that contact switch stop by melting and bonding due to electrical spark. We have studied the evaluation of materials of contact switch for the reducing electrical energy loss and the problem of contact switch operation. In this research, measurement of discharge voltage and high pressure due to underwater shockwave was carried out using the contact switch made of different materials as brass plate, brass-carbon plate-brass and carbon block. The contact switch made of carbon is effective to reduce energy loss and problem of contactor switch operation.

  1. High Voltage Ramp Generator for Electro-Optically Tunable Filter for the MSE-CIF Diagnostics on NSTX.

    Science.gov (United States)

    Wu, Ying; Levinton, Fred

    2004-11-01

    The motional Stark effect (MSE) diagnostic is routinely used to determine the q-profile in large fusion devices. To apply the MSE diagnostic to experiments with low magnetic fields such as NSTX (<1 T), a tunable birefringent Lyot filter is used with high throughput and high resolution which allows for a good signal-to-noise ratio. The birefringent filter is made from lithium-niobate crystals, which are coated with a layer of indium tin-oxide (ITO). The ITO layer is a transparent conductive coating. By applying an electric field across the crystal the index of refraction is varied. This allows tunability of the filter. Putting multiple crystals together and tuning them individually it is possible to pass certain wavelengths of light and reject others. A high voltage ramp generator circuit is under development to ramp a 5 kV signal using a simple design involving MOSFET ladders. The goal is to design the circuit so that it can ramp ±5000 volts at a frequency of around 1 kHz. This would allow the filter to sweep over a range of ˜ 1nm.

  2. METHODICAL APPROACHES TO THE CHOICE OF THE NEW GENERATION OF HIGH-VOLTAGE POWER TRANSMISSION LINE 220 kV OPTIONS

    OpenAIRE

    POSTOLATI V.M.; E. V. Bykova; SUSLOVI V.M.; SHAKARYAN Ui.G; TIMASHOVA L.V.; KAREVA S.N.

    2010-01-01

    The Transmission Power Lines of new generation are described in the article (single- compact, double-circuit compact, double-circuit Controlled Self-compensating High Voltage Transmission Power Lines (CSHVL). Basic principles of creation, design elements and comparative characteristics of the transmission lines of the new generation are described, the advantages of its are showed. Methodical approaches to the choosing of a new generation of transmission lines and facilities management FACTS a...

  3. Failures’ Study of a New Character Three-Phase High Voltage Supply for industrial Microwave Generators with one magnetrons per Phase

    Directory of Open Access Journals (Sweden)

    R. Batit

    2016-04-01

    Full Text Available This article treats the development of one of the equivalent electrical models for a single phase power supply for one magnetron; in particular that of its own high voltage (HV transformer newly dimensioned. This single phase system supplies a voltage doubler and current stabilizer circuit, which supplies a single magnetron. Then, by star connecting the three identical models of the single-phase power supply for one magnetron, we obtain a new character three-phase high voltage power supply for industrial microwave generators with one magnetron per phase. The simulation with EMTP (Electro Magnetic Transcients Program in nominal operation has given the theoretical results close to the experimental measurements. Finally, the magnetrons’ failure of the microwave generator was also treated and allowed to observe the interaction’s influence between magnetrons; also the regulation of the anode current has been achieved successfully.

  4. Design of high-throughput and low-power true random number generator utilizing perpendicularly magnetized voltage-controlled magnetic tunnel junction

    Directory of Open Access Journals (Sweden)

    Hochul Lee

    2017-05-01

    Full Text Available A true random number generator based on perpendicularly magnetized voltage-controlled magnetic tunnel junction devices (MRNG is presented. Unlike MTJs used in memory applications where a stable bit is needed to store information, in this work, the MTJ is intentionally designed with small perpendicular magnetic anisotropy (PMA. This allows one to take advantage of the thermally activated fluctuations of its free layer as a stochastic noise source. Furthermore, we take advantage of the voltage dependence of anisotropy to temporarily change the MTJ state into an unstable state when a voltage is applied. Since the MTJ has two energetically stable states, the final state is randomly chosen by thermal fluctuation. The voltage controlled magnetic anisotropy (VCMA effect is used to generate the metastable state of the MTJ by lowering its energy barrier. The proposed MRNG achieves a high throughput (32 Gbps by implementing a 64×64 MTJ array into CMOS circuits and executing operations in a parallel manner. Furthermore, the circuit consumes very low energy to generate a random bit (31.5 fJ/bit due to the high energy efficiency of the voltage-controlled MTJ switching.

  5. Design of high-throughput and low-power true random number generator utilizing perpendicularly magnetized voltage-controlled magnetic tunnel junction

    Science.gov (United States)

    Lee, Hochul; Ebrahimi, Farbod; Amiri, Pedram Khalili; Wang, Kang L.

    2017-05-01

    A true random number generator based on perpendicularly magnetized voltage-controlled magnetic tunnel junction devices (MRNG) is presented. Unlike MTJs used in memory applications where a stable bit is needed to store information, in this work, the MTJ is intentionally designed with small perpendicular magnetic anisotropy (PMA). This allows one to take advantage of the thermally activated fluctuations of its free layer as a stochastic noise source. Furthermore, we take advantage of the voltage dependence of anisotropy to temporarily change the MTJ state into an unstable state when a voltage is applied. Since the MTJ has two energetically stable states, the final state is randomly chosen by thermal fluctuation. The voltage controlled magnetic anisotropy (VCMA) effect is used to generate the metastable state of the MTJ by lowering its energy barrier. The proposed MRNG achieves a high throughput (32 Gbps) by implementing a 64 ×64 MTJ array into CMOS circuits and executing operations in a parallel manner. Furthermore, the circuit consumes very low energy to generate a random bit (31.5 fJ/bit) due to the high energy efficiency of the voltage-controlled MTJ switching.

  6. Analysis of a novel autonomous marine hybrid power generation/energy storage system with a high-voltage direct current link

    DEFF Research Database (Denmark)

    Wang, L.; Lee, D. J.; Lee, W. J.

    2008-01-01

    This paper presents both time-domain and frequency-domain simulated results of a novel marine hybrid renewable-energy power generation/energy storage system (PG/ESS) feeding isolated loads through an high-voltage direct current (HVDC) link. The studied marine PG subsystems comprise both offshore...

  7. Associating ground magnetometer observations with current or voltage generators

    DEFF Research Database (Denmark)

    Hartinger, M. D.; Xu, Z.; Clauer, C. R.

    2017-01-01

    A circuit analogy for magnetosphere-ionosphere current systems has two extremes for driversof ionospheric currents: ionospheric elec tric fields/voltages constant while current/conductivity vary—the“voltage generator”—and current constant while electric field/conductivity vary—the “current generator.......”Statistical studies of ground magnetometer observations associated with dayside Transient High LatitudeCurrent Systems (THLCS) driven by similar mechanisms find contradictory results using this paradigm:some studies associate THLCS with voltage generators, others with current generators. We argue that mostof...... these two assumptions substantially alter expectations for magnetic perturbations associatedwith either a current or a voltage generator. Our results demonstrate that before interpreting groundmagnetometer observations of THLCS in the context of current/voltage generators, the location...

  8. Calibration of Voltage Transformers and High- Voltage Capacitors at NIST

    Science.gov (United States)

    Anderson, William E.

    1989-01-01

    The National Institute of Standards and Technology (NIST) calibration service for voltage transformers and high-voltage capacitors is described. The service for voltage transformers provides measurements of ratio correction factors and phase angles at primary voltages up to 170 kV and secondary voltages as low as 10 V at 60 Hz. Calibrations at frequencies from 50–400 Hz are available over a more limited voltage range. The service for high-voltage capacitors provides measurements of capacitance and dissipation factor at applied voltages ranging from 100 V to 170 kV at 60 Hz depending on the nominal capacitance. Calibrations over a reduced voltage range at other frequencies are also available. As in the case with voltage transformers, these voltage constraints are determined by the facilities at NIST. PMID:28053409

  9. Modular High Voltage Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    Newell, Matthew R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-18

    The goal of this project is to develop a modular high voltage power supply that will meet the needs of safeguards applications and provide a modular plug and play supply for use with standard electronic racks.

  10. METHODICAL APPROACHES TO THE CHOICE OF THE NEW GENERATION OF HIGH-VOLTAGE POWER TRANSMISSION LINE 220 kV OPTIONS

    Directory of Open Access Journals (Sweden)

    POSTOLATI V.M.

    2010-08-01

    Full Text Available The Transmission Power Lines of new generation are described in the article (single- compact, double-circuit compact, double-circuit Controlled Self-compensating High Voltage Transmission Power Lines (CSHVL. Basic principles of creation, design elements and comparative characteristics of the transmission lines of the new generation are described, the advantages of its are showed. Methodical approaches to the choosing of a new generation of transmission lines and facilities management FACTS are formulated. Methodical approaches to the choice of options for transmission lines 220 kV and facilities management are shown.

  11. Impedance matching for repetitive high voltage all-solid-state Marx generator and excimer DBD UV sources

    Science.gov (United States)

    Wang, Yonggang; Tong, Liqing; Liu, Kefu

    2017-06-01

    The purpose of impedance matching for a Marx generator and DBD lamp is to limit the output current of the Marx generator, provide a large discharge current at ignition, and obtain fast voltage rising/falling edges and large overshoot. In this paper, different impedance matching circuits (series inductor, parallel capacitor, and series inductor combined with parallel capacitor) are analyzed. It demonstrates that a series inductor could limit the Marx current. However, the discharge current is also limited. A parallel capacitor could provide a large discharge current, but the Marx current is also enlarged. A series inductor combined with a parallel capacitor takes full advantage of the inductor and capacitor, and avoids their shortcomings. Therefore, it is a good solution. Experimental results match the theoretical analysis well and show that both the series inductor and parallel capacitor improve the performance of the system. However, the series inductor combined with the parallel capacitor has the best performance. Compared with driving the DBD lamp with a Marx generator directly, an increase of 97.3% in radiant power and an increase of 59.3% in system efficiency are achieved using this matching circuit.

  12. High performance pulse generator

    Science.gov (United States)

    Grothaus, Michael G.; Moran, Stuart L.; Hardesty, Leonard W.

    1992-06-01

    The device is a compact Marx-type generator capable of producing a high-voltage burst of pulses having risetimes less than 10 nanoseconds at repetition rates up to 10 kHz. High-pressure hydrogen switches are used as the switching elements to achieve high rep-rate. A small coaxial design provides low inductance and a fast risetime. The device may be used as a high-rep-rate high-voltage trigger generator, or as a high-voltage pulse source capable of producing up to 1 MV pulses at high repetition rates.

  13. High-Voltage Thermionic Reactor Using Double-Sheath Fuel Elements, 3rd Interational Electrical Power Generation

    Energy Technology Data Exchange (ETDEWEB)

    Schock, Alfred

    1972-06-01

    A novel design concept for a "flashlight-type" in-core thermionic reactor is described. This concept, called the "double-sheath" design in contrast to the previously considered "wet-sheath" and "dry-sheath" concepts, permits the build-up of high reactor output voltages, without the danger of cesium breakdown and shorts-to-ground. In addition to a description of the design and its functional components, a brief discussion of suggested fuel element fabrication and reactor assembly techniques is presented. The proposed design offers the potential of high reliability because only insulators at very low potentials (e.g.<3 volts) are in contact with cesium vapor; because there are no ceramic or cermet seals within the reactor (all are outside, beyond the reflectors); and because all vacuum-tight joints in the reactor are between ductile niobium components.

  14. 46 CFR 120.324 - Dual voltage generators.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Dual voltage generators. 120.324 Section 120.324... INSTALLATION Power Sources and Distribution Systems § 120.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The neutral of a dual voltage...

  15. 46 CFR 129.326 - Dual-voltage generators.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Dual-voltage generators. 129.326 Section 129.326... INSTALLATIONS Power Sources and Distribution Systems § 129.326 Dual-voltage generators. If a dual-voltage generator is installed on an OSV— (a) The neutral of the dual-voltage system must be solidly grounded at the...

  16. Doubly-Fed Induction Generator Control Under Voltage Sags

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Blaabjerg, Frede; Lima, K.

    2008-01-01

    This paper proposes a new control technique to improve the fault-ride through capability of doubly fed induction generators (DFIG). In such generators the appearance of severe voltage sags at the coupling point make rise to high over currents at the rotor/stator windings, something that makes...

  17. Transient voltage sharing in series-coupled high voltage switches

    Directory of Open Access Journals (Sweden)

    Editorial Office

    1992-07-01

    Full Text Available For switching voltages in excess of the maximum blocking voltage of a switching element (for example, thyristor, MOSFET or bipolar transistor such elements are often coupled in series - and additional circuitry has to be provided to ensure equal voltage sharing. Between each such series element and system ground there is a certain parasitic capacitance that may draw a significant current during high-speed voltage transients. The "open" switch is modelled as a ladder network. Analy­sis reveals an exponential progression in the distribution of the applied voltage across the elements. Overstressing thus oc­curs in some of the elements at levels of the total voltage that are significantly below the design value. This difficulty is overcome by grading the voltage sharing circuitry, coupled in parallel with each element, in a prescribed manner, as set out here.

  18. High-voltage test and measuring techniques

    CERN Document Server

    Hauschild, Wolfgang

    2014-01-01

    It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  19. High-Voltage Droplet Dispenser

    Science.gov (United States)

    Eichenberg, Dennis J.

    2003-01-01

    An apparatus that is extremely effective in dispensing a wide range of droplets has been developed. This droplet dispenser is unique in that it utilizes a droplet bias voltage, as well as an ionization pulse, to release a droplet. Apparatuses that deploy individual droplets have been used in many applications, including, notably, study of combustion of liquid fuels. Experiments on isolated droplets are useful in that they enable the study of droplet phenomena under well-controlled and simplified conditions. In this apparatus, a syringe dispenses a known value of liquid, which emerges from, and hangs onto, the outer end of a flat-tipped, stainless steel needle. Somewhat below the needle tip and droplet is a ring electrode. A bias high voltage, followed by a high-voltage pulse, is applied so as to attract the droplet sufficiently to pull it off the needle. The voltages are such that the droplet and needle are negatively charged and the ring electrode is positively charged.

  20. Automated tube voltage selection in thoracoabdominal computed tomography at high pitch using a third-generation dual-source scanner: image quality and radiation dose performance.

    Science.gov (United States)

    Lurz, Markus; Lell, Michael M; Wuest, Wolfgang; Eller, Achim; Scharf, Michael; Uder, Michael; May, Matthias Stefan

    2015-05-01

    The objective of this study was to evaluate the radiation dose and image quality performance of thoracoabdominal examinations with an automated tube voltage selection (tube voltage adaptation), tube current modulation, and high pitch using a third-generation dual-source computed tomography (CT) compared intraindividually with 120-kV examinations with tube current modulation with special attention on clinically relevant lesions in the liver, the lungs, and extrahepatic soft tissues. This study was approved by the institutional review board. Computed tomography of the body was performed using a third-generation dual-source system in 95 patients (mean body mass index, 25 kg/m²; range, 18-35 kg/m²). For 49 of these patients, all calculated tube settings and resulting dose values were recorded for each of the 12 gradual contrast weightings of the tube voltage adaptation algorithm. Spiral CT was performed for all patients with an intermediate weighting (grade 7) in a portal venous phase at 120 reference kV, 180 reference mAs, and pitch of 1.55. Objective image quality was assessed on the basis of contrast-to-noise ratio. Subjective image quality was assessed on the basis of clarity and sharpness of anatomical and pathological structures as well as interfering beam hardening and spiral and motion artifacts (heart, lungs, diaphragm). Previous examinations on a 64-slice scanner served as reference. All examinations were rated good or excellent for clinical diagnosis. Automated tube voltage selection resulted in significantly lower effective radiation dose (9.5 mSv) compared with the reference (12.0 mSv; P radiation dose reduction while substantially increasing the image quality, even at large-volume exposure.

  1. Design and measurements of a fast high-voltage pulse generator for the MedAustron Low Energy Transfer line fast deflector

    CERN Document Server

    Fowler, T; Mueller, F; Kramer, T; Stadlbauer, T

    2012-01-01

    MedAustron, a centre for ion-therapy and research, will comprise an accelerator facility based on a synchrotron for the delivery of protons and light ions for cancer treatment. The Low Energy Beam Transfer line (LEBT) to the synchrotron contains an electrostatic fast deflector (EFE) which, when energized, deviates the continuous beam arriving from the ion source onto a Faraday Cup: the specified voltage is ±3.5 kV. De-energizing the EFE for variable pulse durations from 500 ns up to d.c. allows beam passage for multi-turn injection into the synchrotron. To maintain beam quality in the synchrotron, the EFE pulse generator requires rise and fall times of less than 300 ns between 90 % of peak voltage and a ±1 V level. To achieve this, a pulsed power supply (PKF), with high voltage MOSFET switches connected in a push-pull configuration, will be mounted in close proximity to the deflector itself. A fast, large dynamic range monitoring circuit will verify switching to the ±1 V level and subsequent flat bottom pu...

  2. TRANSISTOR HIGH VOLTAGE POWER SUPPLY

    Science.gov (United States)

    Driver, G.E.

    1958-07-15

    High voltage, direct current power supplies are described for use with battery powered nuclear detection equipment. The particular advantages of the power supply described, are increased efficiency and reduced size and welght brought about by the use of transistors in the circuit. An important feature resides tn the employment of a pair of transistors in an alternatefiring oscillator circuit having a coupling transformer and other circuit components which are used for interconnecting the various electrodes of the transistors.

  3. Advances in high voltage engineering

    CERN Document Server

    Haddad, A

    2005-01-01

    This book addresses the very latest research and development issues in high voltage technology and is intended as a reference source for researchers and students in the field, specifically covering developments throughout the past decade. This unique blend of expert authors and comprehensive subject coverage means that this book is ideally suited as a reference source for engineers and academics in the field for years to come.

  4. Intelligent Distribution Voltage Control with Distributed Generation =

    Science.gov (United States)

    Castro Mendieta, Jose

    In this thesis, three methods for the optimal participation of the reactive power of distributed generations (DGs) in unbalanced distributed network have been proposed, developed, and tested. These new methods were developed with the objectives of maintain voltage within permissible limits and reduce losses. The first method proposes an optimal participation of reactive power of all devices available in the network. The propose approach is validated by comparing the results with other methods reported in the literature. The proposed method was implemented using Simulink of Matlab and OpenDSS. Optimization techniques and the presentation of results are from Matlab. The co-simulation of Electric Power Research Institute's (EPRI) OpenDSS program solves a three-phase optimal power flow problem in the unbalanced IEEE 13 and 34-node test feeders. The results from this work showed a better loss reduction compared to the Coordinated Voltage Control (CVC) method. The second method aims to minimize the voltage variation on the pilot bus on distribution network using DGs. It uses Pareto and Fuzzy-PID logic to reduce the voltage variation. Results indicate that the proposed method reduces the voltage variation more than the other methods. Simulink of Matlab and OpenDSS is used in the development of the proposed approach. The performance of the method is evaluated on IEEE 13-node test feeder with one and three DGs. Variables and unbalanced loads are used, based on real consumption data, over a time window of 48 hours. The third method aims to minimize the reactive losses using DGs on distribution networks. This method analyzes the problem using the IEEE 13-node test feeder with three different loads and the IEEE 123-node test feeder with four DGs. The DGs can be fixed or variables. Results indicate that integration of DGs to optimize the reactive power of the network helps to maintain the voltage within the allowed limits and to reduce the reactive power losses. The thesis is

  5. Energy Storage Options for Voltage Support in Low-Voltage Grids with High Penetration of Photovoltaic

    DEFF Research Database (Denmark)

    Marra, Francesco; Tarek Fawzy, Y.; Bülo, Thorsten

    2012-01-01

    The generation of power by photovoltaic (PV) systems is constantly increasing in low-voltage (LV) distribution grids, in line with the European environmental targets. To cope with the effects on grid voltage profiles during high generation and low demand periods, new solutions need to be establis......The generation of power by photovoltaic (PV) systems is constantly increasing in low-voltage (LV) distribution grids, in line with the European environmental targets. To cope with the effects on grid voltage profiles during high generation and low demand periods, new solutions need...... to be established. In the long term, these solutions should also aim to allow further more PV installed capacity, while meeting the power quality requirements. In this paper, different concepts of energy storage are proposed to ensure the voltage quality requirements in a LV grid with high PV penetration...

  6. 46 CFR 183.324 - Dual voltage generators.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Dual voltage generators. 183.324 Section 183.324... TONS) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The...

  7. Energy harvesting in high voltage measuring techniques

    Science.gov (United States)

    Żyłka, Pawel; Doliński, Marcin

    2016-02-01

    The paper discusses selected problems related to application of energy harvesting (that is, generating electricity from surplus energy present in the environment) to supply autonomous ultra-low-power measurement systems applicable in high voltage engineering. As a practical example of such implementation a laboratory model of a remote temperature sensor is presented, which is self-powered by heat generated in a current-carrying busbar in HV- switchgear. Presented system exploits a thermoelectric harvester based on a passively cooled Peltier module supplying micro-power low-voltage dc-dc converter driving energy-efficient temperature sensor, microcontroller and a fibre-optic transmitter. Performance of the model in laboratory simulated conditions are presented and discussed.

  8. Low power, scalable multichannel high voltage controller

    Science.gov (United States)

    Stamps, James Frederick [Livermore, CA; Crocker, Robert Ward [Fremont, CA; Yee, Daniel Dadwa [Dublin, CA; Dils, David Wright [Fort Worth, TX

    2008-03-25

    A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

  9. High-Voltage Digital-To-Analog Converter

    Science.gov (United States)

    Huston, Steven W.

    1990-01-01

    High-voltage 10-bit digital-to-analog converter operates under computer control to put out voltages up to 500 V at currents up to 35 mA. Circuit includes high-voltage power supply used to generate high-voltage square wave at frequency set by computer at value between 0.2 Hz and 10 Hz. Used to drive 0.02-microfarad, 1-kV capacitor at slewing rate of 1 V/microsecond to provide signal for robotic imaging system.

  10. High Voltage Nanosecond Pulse Generator.

    Science.gov (United States)

    1978-11-01

    pulse to a laser load was desiqned , built , and tested . —- -~~~-~~~~----j ‘~ ~~ _)— ~ --. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ CoIx ~r 1 I

  11. Associating ground magnetometer observations with current or voltage generators

    DEFF Research Database (Denmark)

    Hartinger, M. D.; Xu, Z.; Clauer, C. R.

    2017-01-01

    .”Statistical studies of ground magnetometer observations associated with dayside Transient High LatitudeCurrent Systems (THLCS) driven by similar mechanisms find contradictory results using this paradigm:some studies associate THLCS with voltage generators, others with current generators. We argue that mostof...... this contradiction arises from two assumptions used to interpret ground magnetometer observations:(1) measurements made at fixed position relative to the THLCS field-aligned current and (2) negligibleauroral precipitation contributions to ionospheric conductivity. We use observations and simulations toillustrate how...

  12. High voltage MOSFET switching circuit

    Science.gov (United States)

    McEwan, Thomas E.

    1994-01-01

    The problem of source lead inductance in a MOSFET switching circuit is compensated for by adding an inductor to the gate circuit. The gate circuit inductor produces an inductive spike which counters the source lead inductive drop to produce a rectangular drive voltage waveform at the internal gate-source terminals of the MOSFET.

  13. High-voltage engineering and testing

    CERN Document Server

    Ryan, Hugh M

    2013-01-01

    This 3rd edition of High Voltage Engineering Testing describes strategic developments in the field and reflects on how they can best be managed. All the key components of high voltage and distribution systems are covered including electric power networks, UHV and HV. Distribution systems including HVDC and power electronic systems are also considered.

  14. Improving Low Voltage Ride Through Capability of Wind Generators Using Dynamic Voltage Restorer

    Science.gov (United States)

    Sivasankar, Gangatharan; Suresh Kumar, Velu

    2014-08-01

    The increasing wind power integration with power grid has forced the situation to improve the reliability of wind generators for stable operation. One important problem with induction generator based wind farm is its low ride through capability to the grid voltage disturbance. Any disturbance such as voltage dip may cause wind farm outages. Since wind power contribution is in predominant percentage, such outages may lead to stability problem. The proposed strategy is to use dynamic voltage controller (DVR) to compensate the voltage disturbance. The DVR provides the wind generator the ability to remain connected in grid and improve the reliability. The voltage dips due to symmetrical and unsymmetrical faults are considered for analysis. The vector control scheme is employed for fault compensation which uses software phase locked loop scheme and park dq0 transformation technique. Extensive simulation results are included to illustrate the control and operation of DVR.

  15. High-voltage power supply unit

    CERN Document Server

    Garipov, G K; Silaev, A A; Shirokov, A V

    2002-01-01

    A unit comprising four high-voltage power sources (HPS) is designed for power supply of four independent photomultipliers. Each HPS comprises a pulse-width modulator, digital-to-analog converter, base voltage source and digital interface. HPS unit supplies up to 2000 V output voltage, up to 2.5 mA current and long-term stability equal to +- 0.03%

  16. Planar LTCC transformers for high voltage flyback converters.

    Energy Technology Data Exchange (ETDEWEB)

    Schofield, Daryl (NASCENT Technology Inc. , Watertown, SD); Schare, Joshua M.; Glass, Sarah Jill; Roesler, Alexander William; Ewsuk, Kevin Gregory; Slama, George (NASCENT Technology Inc. , Watertown, SD); Abel, Dave (NASCENT Technology Inc. , Watertown, SD)

    2007-06-01

    This paper discusses the design and use of low-temperature (850 C to 950 C) co-fired ceramic (LTCC) planar magnetic flyback transformers for applications that require conversion of a low voltage to high voltage (> 100V) with significant volumetric constraints. Measured performance and modeling results for multiple designs showed that the LTCC flyback transformer design and construction imposes serious limitations on the achievable coupling and significantly impacts the transformer performance and output voltage. This paper discusses the impact of various design factors that can provide improved performance by increasing transformer coupling and output voltage. The experiments performed on prototype units demonstrated LTCC transformer designs capable of greater than 2 kV output. Finally, the work investigated the effect of the LTCC microstructure on transformer insulation. Although this paper focuses on generating voltages in the kV range, the experimental characterization and discussion presented in this work applies to designs requiring lower voltage.

  17. Fractional-order Systems and Synchronous Generator Voltage Regulator

    Directory of Open Access Journals (Sweden)

    Wojciech Lubośny

    2015-03-01

    Full Text Available Modern regulators of synchronous generators, including voltage regulators, are digital systems, in their vast majority with standard structures contained in the IEEE standard. These are systems described with stationary differential equations of integral order. Differential equations of fractional order are not employed in regulators for synchronous generator control. This paper presents an analysis of the possibilities of using a system of fractional differential equations in the voltage regulator of an synchronous generator with a static excitation system.

  18. Advanced High Voltage Power Device Concepts

    CERN Document Server

    Baliga, B Jayant

    2012-01-01

    Advanced High Voltage Power Device Concepts describes devices utilized in power transmission and distribution equipment, and for very high power motor control in electric trains and steel-mills. Since these devices must be capable of supporting more than 5000-volts in the blocking mode, this books covers operation of devices rated at 5,000-V, 10,000-V and 20,000-V. Advanced concepts (the MCT, the BRT, and the EST) that enable MOS-gated control of power thyristor structures are described and analyzed in detail. In addition, detailed analyses of the silicon IGBT, as well as the silicon carbide MOSFET and IGBT, are provided for comparison purposes. Throughout the book, analytical models are generated to give a better understanding of the physics of operation for all the structures. This book provides readers with: The first comprehensive treatment of high voltage (over 5000-volts) power devices suitable for the power distribution, traction, and motor-control markets;  Analytical formulations for all the device ...

  19. Enhancement of AC high voltage measurements’ uncertainty using a high voltage divider calibration method

    Directory of Open Access Journals (Sweden)

    El-Rifaie Ali M.

    2015-01-01

    Full Text Available This paper discusses enhancing of the measurements’ uncertainty for AC high voltage up to 100 kV. This is achieved by using a high voltage divider calibration method. Voltage measurements have been carried out at the Egyptian national institute for standards (NIS, using a high voltage measuring system (Phenix-KVM100, that consists of a high voltage divider and a voltage display. The voltage divider and display have been calibrated in low and high voltage ranges. Reference standard digital voltmeter and a multifunction calibrator have been used to calibrate the KVM100 for achieving accurate and traceable results. All calibrations have been performed automatically using Laboratory Virtual Instrument Engineering Workbench (LabVIEW programs specially designed for this task. Uncertainty budget has been evaluated to get the measurements’ expanded uncertainties.

  20. Compact, Lightweight, High Voltage Propellant Isolators Project

    Data.gov (United States)

    National Aeronautics and Space Administration — TA&T, Inc. proposes an enabling fabrication process for high voltage isolators required in high power solar electric and nuclear electric propulsion (SEP and...

  1. High voltage electricity installations a planning perspective

    CERN Document Server

    Jay, Stephen Andrew

    2006-01-01

    The presence of high voltage power lines has provoked widespread concern for many years. High Voltage Electricity Installations presents an in-depth study of policy surrounding the planning of high voltage installations, discussing the manner in which they are percieved by the public, and the associated environmental issues. An analysis of these concerns, along with the geographical, environmental and political influences that shape their expression, is presented. Investigates local planning policy in an area of the energy sector that is of highly topical environmental and public concern Cover

  2. Impact of Voltage Conditions on Distributed Generation Connectivity in Medium Voltage Grids

    OpenAIRE

    Ireneusz Grządzielski; Krzysztof Marszałkiewicz; Andrzej Trzeciak

    2015-01-01

    A significant increase in the distributed generating sources connected and planned for connection to medium voltage (MV) grids makes voltage criteria very important in assessing the sources’ connectivity. Many requests have been submitted for connection of distributed generation sources at a considerable distance (even a dozen or so kilometres) from a main supply substation’s MV buses. As a rule, these are requests for the interconnection deep in an existing MV bus, but also directly to MV sw...

  3. Impact of Voltage Conditions on Distributed Generation Connectivity in Medium Voltage Grids

    Directory of Open Access Journals (Sweden)

    Ireneusz Grządzielski

    2015-12-01

    Full Text Available A significant increase in the distributed generating sources connected and planned for connection to medium voltage (MV grids makes voltage criteria very important in assessing the sources’ connectivity. Many requests have been submitted for connection of distributed generation sources at a considerable distance (even a dozen or so kilometres from a main supply substation’s MV buses. As a rule, these are requests for the interconnection deep in an existing MV bus, but also directly to MV switching substation bays. Then maintaining appropriate voltage levels becomes a basic technical problem. Another technical problem relates to meeting the power quality criteria. THD index, and the level of individual harmonics, significantly increases, in many cases reaching or even exceeding the boundary values. With their extensive experience, the authors present examples and results of some analyses herewith. They indicate the impact of voltage conditions on the connection possibilities of distributed generation to MV grids.

  4. Integrated differential high-voltage transmitting circuit for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Farch, Kjartan

    2015-01-01

    In this paper an integrated differential high-voltage transmitting circuit for capacitive micromachined ultrasonic transducers (CMUTs) used in portable ultrasound scanners is designed and implemented in a 0.35 μm high-voltage process. Measurements are performed on the integrated circuit in order...... to assess its performance. The circuit generates pulses at differential voltage levels of 60V, 80V and 100 V, a frequency up to 5MHz and a measured driving strength of 1.75 V/ns with the CMUT connected. The total on-chip area occupied by the transmitting circuit is 0.18 mm2 and the power consumption...

  5. High voltage and electrical insulation engineering

    CERN Document Server

    Arora, Ravindra

    2011-01-01

    "The book is written for students as well as for teachers and researchers in the field of High Voltage and Insulation Engineering. It is based on the advance level courses conducted at TU Dresden, Germany and Indian Institute of Technology Kanpur, India. The book has a novel approach describing the fundamental concept of field dependent behavior of dielectrics subjected to high voltage. There is no other book in the field of high voltage engineering following this new approach in describing the behavior of dielectrics. The contents begin with the description of fundamental terminology in the subject of high voltage engineering. It is followed by the classification of electric fields and the techniques of field estimation. Performance of gaseous, liquid and solid dielectrics under different field conditions is described in the subsequent chapters. Separate chapters on vacuum as insulation and the lightning phenomenon are included"--

  6. Conversion of Impulse Voltage Generator Into Steep Wave Impulse Test-Equipment

    Science.gov (United States)

    Khan, Mohammed Zaid; Tanwar, Surender Singh; Dayama, Ravindra; Choudhary, Rahul Raj; Mangal, Ravindra

    This paper demonstrates the alternative measures to generate the Steep wave impulse by using Impulse Voltage Generator (IVG) for high voltage testing of porcelain insulators. The modification of IVG by incorporating compensation of resistor, inductor, and capacitor has been achieved and further performance of the modified system has been analyzed by applying the generated lightning impulse and analyzing the electrical characteristics of impulse waves under standard lightning and fast rise multiple lightning waveform to determine the effect to improve rise time. The advantageous results have been received and being reported such as increase in overshoot compensation, increase in capacitive and inductive load ranges. Such further reduces the duration of oscillations of standard impulse voltages. The reduction in oscillation duration of steep front impulse voltages may be utilized in up gradation of Impulse Voltage Generator System. Stray capacitance could further be added in order to get the minimized difference of measurement between simulation and the field establishment.

  7. Simplified Process for Manufacturing Macroscale Patterns to Enhance Voltage Generation by a Triboelectric Generator

    Directory of Open Access Journals (Sweden)

    Jun-Ho Yang

    2015-11-01

    Full Text Available This paper proposes a simple, yet effective and affordable, manufacturing process to enhance the overall efficiency of voltage generation by a triboelectric generator (TEG using 3D printers for energy-harvesting applications. The proposed method can be classified as macroscale surface patterning, in contrast to micro- and nanoscale patterning of TEG proposed in previous studies. Experiments were conducted using a designed test-bed system that allowed the control of external factors, such as the magnitude and frequency of the frictional force and the relative humidity, and an output voltage increase of up to 67% was obtained from a TEG with macroscale patterns that increased the surface area by 14%. The peak voltage generated by the TEG was as high as 18 V, and the addition of a designed analog circuit that uses no external power enabled storage of a DC voltage of 0.4 V. In comparison with previous methods that employ micro- or nanoscale patterns, the proposed patterning method is faster and more suitable for mass production.

  8. Resonance analysis in parallel voltage-controlled Distributed Generation inverters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2013-01-01

    of the inverters and the remaining system dynamics. This paper addresses the later interactions and the consequent resonances through the frequency-domain analysis of the inverters output impedances and the remaining equivalent network impedance. Furthermore, impacts of the virtual output impedance loop......Thanks to the fast responses of the inner voltage and current control loops, the dynamic behaviors of parallel voltage-controlled Distributed Generation (DG) inverters not only relies on the stability of load sharing among them, but subjects to the interactions between the voltage control loops...

  9. Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage: feasibility, image quality, radiation dose, and effect of iterative reconstruction.

    Science.gov (United States)

    Hell, Michaela M; Bittner, Daniel; Schuhbaeck, Annika; Muschiol, Gerd; Brand, Michael; Lell, Michael; Uder, Michael; Achenbach, Stephan; Marwan, Mohamed

    2014-01-01

    Low tube voltage reduces radiation exposure in coronary CT angiography (CTA). Using 70 kVp tube potential has so far not been possible because CT systems were unable to provide sufficiently high tube current with low voltage. We evaluated feasibility, image quality (IQ), and radiation dose of coronary CTA using a third-generation dual-source CT system capable of producing 450 mAs tube current at 70 kVp tube voltage. Coronary CTA was performed in 26 consecutive patients with suspected coronary artery disease, selected for body weight Image noise was lower in IR vs FBP (60 ± 10 HU vs 74 ± 8 HU; P < .001). In patients <100 kg and with a regular heart rate <60 beats/min, third-generation dual-source CT using high-pitch spiral acquisition and 70 kVp tube voltage is feasible and provides both robust IQ and very low radiation exposure. Copyright © 2014 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  10. Performance analysis of voltage regulation in diesel-wind generation

    African Journals Online (AJOL)

    generated by the two sources one source is the diesel engine generator and the other source is the wind energy conversion system the supply is provided to the isolated load. The voltage is regulated at the load side .The electrical energy produced by the wind turbine at constant speed is connected to the specific load by ...

  11. High voltage testing for the Majorana Demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Abgrall, N.; Arnquist, Isaac J.; Avignone, F. T.; Barabash, A.; Bertrand, F.; Bradley, A. W.; Brudanin, V.; Busch, Matthew; Buuck, M.; Byram, D.; Caldwell, A. S.; Chan, Yuen-Dat; Christofferson, C. D.; Chu, Pamela M.; Cuesta, C.; Detwiler, Jason A.; Doe, P. J.; Dunagan, C.; Efremenko, Yuri; Ejiri, H.; Elliott, S. R.; Fu, Z.; Galindo-Uribarri, A.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guinn, I.; Guiseppe, V. E.; Henning, R.; Hoppe, Eric W.; Howard, S.; Howe, M. A.; Jasinski, B. R.; Keeter, K.; Kidd, M. F.; Konovalov, S.; Kouzes, Richard T.; Laferriere, Brian D.; Leon, Jonathan D.; Li, Alexander D.; MacMullin, J.; Martin, R. D.; Massarcyk, R.; Meijer, S. J.; Mertens, S.; Orrell, John L.; O' Shaughnessy, C.; Poon, Alan W.; Radford, D. C.; Rager, J.; Rielage, Keith; Robertson, R. G. H.; Romero Romo, M.; Shanks, B.; Shirchenko, M.; Snyder, N.; Suriano, Anne-Marie E.; Tedeschi, D.; Thompson, Andrew; Ton, K. T.; Trimble, J. E.; Varner, R. L.; Vasilyev, Sergey; Vetter, Kai; Vorren, Kris R.; White, Brandon R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, Chang-Hong; Yumatov, V.

    2016-07-01

    The Majorana Collaboration is constructing theMajorana Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of theMajorana Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the Majorana Demonstrator was characterized and the micro-discharge effects during theMajorana Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

  12. 76 FR 70721 - Voltage Coordination on High Voltage Grids; Notice of Staff Workshop

    Science.gov (United States)

    2011-11-15

    ... Energy Regulatory Commission Voltage Coordination on High Voltage Grids; Notice of Staff Workshop Take notice that the Federal Energy Regulatory Commission will hold a Workshop on Voltage Coordination on High Voltage Grids on Thursday, December 1, 2011 from 9 a.m. to 4:30 p.m. This staff-led workshop will be held...

  13. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    . A detailed analysis of dominant loss factors in high power converters for low voltage applications is presented. The analysis concludes that: • Power transformers for low voltage high power, if properly designed, will have extremely low leakage inductance. • If optimally designed, boost converters......The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based......, if a converter is properly designed, primary side voltage clamp circuits will not even work in low voltage high power converters. • Very high conversion efficiency can be achieved. Peak efficiency of 98% and worst case minimum efficiency of 96.8% are demonstrated on a 1.5 kW converter. The ability...

  14. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    and maximum output power. In chapter 3, a detailed analysis of dominant loss factors in high power converters for low voltage applications is presented. The analysis concludes that: • Power transformers for low voltage high power, if properly designed, will have extremely low leakage inductance......The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based....... • If optimally designed, boost converters will be much more efficient than comparable buck type converters for high power low voltage applications. • The use of voltage clamp circuits to protect primary switches in boost converters is no longer needed for device protection. On the other hand...

  15. Pulsed high voltage discharge induce hematologic changes

    African Journals Online (AJOL)

    STORAGESEVER

    2009-10-19

    Oct 19, 2009 ... The aim of this work to examine the effect of the gas-liquid hybrid discharge treatment system on some hematological ... liquid phase. The high energy plasma arc produces a pressure shock wave, electromagnetic radiations, .... through a 50 kilo-ohm resistor by a negative dc high-voltage power supply and ...

  16. 76 FR 72203 - Voltage Coordination on High Voltage Grids; Notice of Reliability Workshop Agenda

    Science.gov (United States)

    2011-11-22

    ... Energy Regulatory Commission Voltage Coordination on High Voltage Grids; Notice of Reliability Workshop... between voltage control, reliability, and economic dispatch. In addition, the Commission will consider how improvements to dispatch and voltage control software could improve reliability and market efficiency. This...

  17. Modular high voltage power supply for chemical analysis

    Science.gov (United States)

    Stamps, James F [Livermore, CA; Yee, Daniel D [Dublin, CA

    2008-07-15

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  18. Voltage Control in Wind Power Plants with Doubly Fed Generators

    DEFF Research Database (Denmark)

    Garcia, Jorge Martinez

    the reactive power operation of the converters, in steadystate, within a maximum band of 10 %. It is clear that an on-load tap changer system will help to keep the stator voltage close to its nominal value, but the action of the mechanically switched capacitors is badly influencing the on-load tap changer line......In this work, the process of designing a wind power plant composed of; doubly fed induction generators, a static compensator unit, mechanically switched capacitors and on-load tap changer, for voltage control is shown. The selected control structure is based on a decentralized system, since...... measured current at medium voltage, thus reducing the tap moving operations. Finally, due to the wind power plant reactive power is sized for maximum active power level, it is expected that a big amount of reactive power remains unused most of the time due to the wind power generation characteristics...

  19. An Inexpensive Source of High Voltage

    Science.gov (United States)

    Saraiva, Carlos

    2012-01-01

    As a physics teacher I like recycling old apparatus and using them for demonstrations in my classes. In physics laboratories in schools, sources of high voltage include induction coils or electronic systems that can be bought from companies that sell lab equipment. But these sources can be very expensive. In this article, I will explain how you…

  20. 30 CFR 75.804 - Underground high-voltage cables.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground high-voltage cables. 75.804 Section... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.804 Underground high-voltage cables. (a) Underground high-voltage cables used in resistance...

  1. 30 CFR 77.810 - High-voltage equipment; grounding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage equipment; grounding. 77.810... COAL MINES Surface High-Voltage Distribution § 77.810 High-voltage equipment; grounding. Frames, supporting structures, and enclosures of stationary, portable, or mobile high-voltage equipment shall be...

  2. Ultra High Voltage Surge Waveforms Measurement Using an Optical Transducer

    Directory of Open Access Journals (Sweden)

    Francisco G. PEÑA-LECONA

    2010-05-01

    Full Text Available Ultra high voltage surge waveforms measurement by means of a portable optical transducer is presented. The sensor system uses a transducer element based on the longitudinal electro-optic effect with a double pass configuration to obtain a better sensitivity. The transducer head is allocated to one meter of distance from the generating element of electric field and it is able to measure waveform surges from 515 kV up to 1090 kV with fast response. It is demonstrated that the telemetry of ultra high voltage surge waveforms can be successfully done by means of this proposed optical transducer.

  3. Electrical system architecture having high voltage bus

    Science.gov (United States)

    Hoff, Brian Douglas [East Peoria, IL; Akasam, Sivaprasad [Peoria, IL

    2011-03-22

    An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

  4. Optimal operation control of low-voltage grids with a high share of distributed power generation[Dissertation 17063]; Optimierte Betriebsfuehrung von Niederspannungsnetzen mit einem hohen Anteil an dezentraler Erzeugung

    Energy Technology Data Exchange (ETDEWEB)

    Malte, C. T.

    2007-07-01

    The importance of renewable energy sources and combined heat and power generation for electricity production will further increase in the next years, not only in Germany but all over Europe. Beside the conventional more or less centrally organised generation and distribution structure, more and more distributed generation (DG) units of different technologies will come to the forefront. Today's centrally organised electricity supply structure is comparatively stable, relatively simple to control and guarantees a high degree of supply quality. But it requests large investments with a long commitment, is less flexible and can barely use efficiency potentials. Distribution grids (low and medium voltage) are essentially passive; this means that the network management is carried out at the higher voltage levels. As more and more DG units feed in the grid, the distribution grids have to become more 'active'. With a high share of wind power, combined heat and power as well as photovoltaic generation, more duties of grid management have to be carried out at the point of common coupling of DG units. This requests for more communication und new control strategies in the distribution grids. At the same time grids with DG have in the mid-term the potential to reduce the susceptibility for large scale black-outs, because, on one hand, with a high number of smaller and individually controlled DG units the breakdown of one unit does not have a major impact and, on the other hand, with a specific grid management the option exists to build up islanded grids during interruptions on the higher voltage levels and to continue to supply the connected customers. In the European research project 'DISPOWER' 38 institutions from all over Europe dealt these topics. In this context a new kind of energy management system for low voltage grids was developed: 'PoMS'. PoMS is the acronym for 'Power Flow and Power Quality Management System'. Major

  5. Square-Wave Voltage Injection Algorithm for PMSM Position Sensorless Control With High Robustness to Voltage Errors

    DEFF Research Database (Denmark)

    Ni, Ronggang; Xu, Dianguo; Blaabjerg, Frede

    2017-01-01

    relationship with the magnetic field distortion. Position estimation errors caused by higher order harmonic inductances and voltage harmonics generated by the SVPWM are also discussed. Both simulations and experiments are carried out based on a commercial PMSM to verify the superiority of the proposed method......Rotor position estimated with high-frequency (HF) voltage injection methods can be distorted by voltage errors due to inverter nonlinearities, motor resistance, and rotational voltage drops, etc. This paper proposes an improved HF square-wave voltage injection algorithm, which is robust to voltage...... errors without any compensations meanwhile has less fluctuation in the position estimation error. The average position estimation error is investigated based on the analysis of phase harmonic inductances, and deduced in the form of the phase shift of the second-order harmonic inductances to derive its...

  6. COAXIAL DISK SHUNT FOR MEASURING IN THE HEAVY-CURRENT CHAIN OF HIGH-VOLTAGE GENERATOR OF STORM DISCHARGES OF IMPULSES OF CURRENT OF ARTIFICIAL LIGHTNING WITH THE INTEGRAL OF ACTION TO 15•106 J/OHM

    Directory of Open Access Journals (Sweden)

    M. I. Baranov

    2017-10-01

    Full Text Available Purpose. Description of construction and basic technical descriptions developed and created in Research & Design Institute «Molniya» National Technical University «Kharkiv Polytechnic Institute» high-voltage heavy-current coaxial disk shunt of type of SC-300M2, allowing reliably to measure the peak-temporal parameters (PTP of impulses of current of artificial lightning in wide peak and temporal ranges with the integral of their action to 15·106 J/Ohm. Methodology. Electrophysics bases of high-voltage impulsive technique, scientific and technical bases of development and creation of high-voltage heavy-current impulsive electrical equipment, including the powerful generators of current of lightning (GCL, and also measuring methods in bit chains powerful high-voltage GCL AVP large impulsive currents of micro- and millisecond temporal ranges. Results. Offered and described new construction of measuring high-voltage heavy-current shunt, containing a measuring round disk from stainless steel easily soiled a 12Х18Н10Т thickness 2 mm and external diameter 80 mm. Experimental a way impulsive active resistance of RS≈0,08 mOhm of the indicated measuring disk and on his basis a calculation coefficient transformation is found of SS of coaxial disk shunt of type of SC-300M2, numeral equal in the concerted mode of operations of his coaxial cable line (CCL SS≈2/RS≈25·103 A/V. It is rotined that it is expedient to use this value SS for measuring in the heavy-current bit chain of GCL ATP impulsive A- and repeated impulsive D- component of current of artificial lightning, and also ATP of aperiodic impulse of current of artificial lightning of temporal form 10 μc/350 μc. It is set that taking into account application in the end CCL of shunt of a co-ordinate divizor of voltage with two output coaxial sockets 1:1 (for SSA≈25·103 A/V and 1:2 (SSC≈12,5·103 A/V at measuring of ATP intermediate B-, protracted C- and shortened protracted C

  7. Diagnosis of High Voltage Insulators Made of Ceramic Using Spectrophotometry

    Directory of Open Access Journals (Sweden)

    Paweł Frącz

    2016-01-01

    Full Text Available The paper presents results of comparative analysis of optical signals emitted by partial discharges occurring on three types of high voltage insulators made of porcelain. The research work consisted of diagnosis of the following devices: a long rod insulator, a cap insulator, and an insulating cylinder. For optical signal registration a spectrophotometer was applied. All measurements were performed under laboratory conditions by changing the value of partial discharges generation voltage. For the cylindrical insulator also the distance between high voltage and ground electrodes was subjected for investigation as a factor having influence on partial discharges. The main contribution which resulted from the studies is statement that application of spectrophotometer enables faster recognition of partial discharges, as compared to standard methods.

  8. APPLICATION OF HIGH VOLTAGE DIVIDERS FOR POWER QUALITY INDICES MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Y. L. Anokhin

    2017-12-01

    Full Text Available Introduction. Determination of power quality indices in high-voltage power grids allows to find the reasons for the deterioration of the power quality. The relevant national and International Standards for power quality contain relevant norms of quality indices and requirements for their accuracy measurement. Problem. The most complicated part in the process of measuring the power quality indices at high voltage is the selection of the corresponding high-voltage scale voltage converters. Therefore, comparing the requirements of IEC 61000-4-30 to high voltage scale voltage converters is an important task. Goal. Analysis of the International Standard IEC 61000-4-30 requirements feasibility for measuring the indices of power quality in high-voltage electrical networks using different types of high-voltage scale voltage converters. Methodology. Comparison of the requirements of IEC 61000-4-30 Standard to high-voltage scale voltage converters, when measuring power quality indices, with the characteristics of high voltage electromagnetic transformers used in Ukraine, and with promising developments of high-voltage converters of other types. Results. It is shown in the study that in order to fulfill some of the requirements for class A of IEC 61000-4-30, the characteristics of electromagnetic voltage transformers should be determined in the substation conditions using mobile calibration high-voltage laboratories. To meet all the requirements for Class A IEC 61000-4-30, it is recommended to use broadband high-voltage dividers of resistive-capacitive type. Originality. In study it is shown firstly that all the requirements of the IEC 61000-4-30 Standard for high-voltage scale voltage converters can be performed on the basis of the use of broadband resistive-capacitive damped voltage dividers. Practical value. Expositions of specific types of resistive-capacitive high-voltage dividers are presented, their parameters are confirmed by the results of state

  9. A multilevel voltage-source inverter with separate dc sources for static var generation

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Fang Zheng [Tennessee Univ., Knoxville, TN (United States)]|[Oak Ridge National Lab., TN (United States); Lai, Jih-Sheng; McKeever, J.; VanCoevering, J. [Oak Ridge National Lab., TN (United States)

    1995-09-01

    A new multilevel voltage-source inverter with a separate dc sources is proposed for high-voltage, high-power applications, such as flexible ac transmission systems (FACTS) including static var generation (SVG), power line conditioning, series compensation, phase shifting, voltage balancing, fuel cell and photovoltaic utility systems interfacing, etc. The new M-level inverter consists of (M-1)/2 single phase full bridges in which each bridge has its own separate dc source. This inverter can generate almost sinusoidal waveform voltage with only one time switching per cycle as the number of levels increases. It can solve the problems of conventional transformer-based multipulse inverters and the problems of the multilevel diode-clamped inverter and the multilevel flying capacitor inverter. To demonstrate the superiority of the new inverter, a SVG system using the new inverter topology is discussed through analysis, simulation and experiment.

  10. Voltage Stabilization Control of Wide-Speed-Range Permanent-Magnet Synchronous Generator Systems

    OpenAIRE

    Miao, Dongmin

    2016-01-01

    DC power systems have a constant DC-link voltage, as well as the advantages such as high stability, high efficiency, small size and light weight; therefore, they are widely used in stand-alone power systems, e.g. the power systems in aircrafts and automobiles, isolated wind power generation systems, etc. Permanent-Magnet Synchronous Generators (PMSGs) possess the advantages including high power density, high efficiency, and high control precision, and have obtained great attention and have be...

  11. High-voltage multijunction photovoltaic solar cell

    Energy Technology Data Exchange (ETDEWEB)

    Doroshenko, V.G.; Zaks, M.B.; Kalash' yan, V.A.; Lozovskiy, V.N.; Skokov, Yu.V.; Solodukha, O.I.

    1979-01-01

    The possibility of developing a high-voltage multijunction photovoltaic cell (HMPC) based on a single crystal with multiple vertical p-n junctions formed by heavily doped zones at right angles to the illuminated surface of the instrument is demonstrated. A laboratory technology for producing HMPC based on the zone recrystallization method with a temperature gradient and linear zones is presented. The investigated variant of HMPC was made of n-type silicon with resistivity of 1 ohm.cm in which are formed vertical p/sup +/ type zones doped with aluminum or an aluminum-boron alloy. The performance HMPC (with 11 and 5 vertical p-n junctions) was experimentally investigated in the presence of 400 to 500 ms light pulses from a xenon lamp with a near-solar spectrum and the current-voltage characteristic of the HMPC was found to be then virtually unaffected.

  12. Modeling and Stress Analysis of Doubly-Fed Induction Generator during Grid Voltage Swell

    DEFF Research Database (Denmark)

    Zhou, Dao; Song, Yipeng; Blaabjerg, Frede

    2016-01-01

    the DFIG modeling and challenges when facing the symmetrical voltage swell. Then, the High Voltage Ride-Through (HVRT) capability of the DFIG can be calculated by using the demagnetizing current control, and the stator current, rotor current as well as the electromagnetic torque can be deduced during...... the transient voltage swell and its recovery. It is concluded that although both higher swell level and higher rotor speed cause higher rotor electromotive force, the doubly-fed induction generator can successfully ride through the grid fault due to the relatively small swell level required by the modern grid...

  13. Impact of Distributed Generation on the Voltage Sag Performance of Transmission Systems

    Directory of Open Access Journals (Sweden)

    Pierluigi Caramia

    2017-07-01

    Full Text Available In this paper, we analysed the growing penetration of generating units from renewable energy sources in transmission power systems. Among the possible effects of the interaction of distributed generation (DG with transmission systems, we considered the abnormal operating conditions caused by short circuits in the transmission systems and the resulting voltage sags that occur in the network. A systematic method is presented for analysing the voltage sag behaviour of any transmission system in which large DG units are connected to the transmission system by means of High Voltage/Medium Voltage (HV/MV stations. The method proposed for obtaining the voltage sags is the fault position method (FPM, from which we derived a graphical visualization of the during-fault voltage (DFV matrix as a valuable tool to obtain an immediate measure of the propagation of voltage sags in the network. The results obtained were based on a portion of a real transmission system. The system that we considered is an actual portion of the Italian transmission system, and all of the quantities we used were obtained from the data of the Transmission system operator (TSO.

  14. Generator voltage stabilisation for series-hybrid electric vehicles.

    Science.gov (United States)

    Stewart, P; Gladwin, D; Stewart, J; Cowley, R

    2008-04-01

    This paper presents a controller for use in speed control of an internal combustion engine for series-hybrid electric vehicle applications. Particular reference is made to the stability of the rectified DC link voltage under load disturbance. In the system under consideration, the primary power source is a four-cylinder normally aspirated gasoline internal combustion engine, which is mechanically coupled to a three-phase permanent magnet AC generator. The generated AC voltage is subsequently rectified to supply a lead-acid battery, and permanent magnet traction motors via three-phase full bridge power electronic inverters. Two complementary performance objectives exist. Firstly to maintain the internal combustion engine at its optimal operating point, and secondly to supply a stable 42 V supply to the traction drive inverters. Achievement of these goals minimises the transient energy storage requirements at the DC link, with a consequent reduction in both weight and cost. These objectives imply constant velocity operation of the internal combustion engine under external load disturbances and changes in both operating conditions and vehicle speed set-points. An electronically operated throttle allows closed loop engine velocity control. System time delays and nonlinearities render closed loop control design extremely problematic. A model-based controller is designed and shown to be effective in controlling the DC link voltage, resulting in the well-conditioned operation of the hybrid vehicle.

  15. High Voltage in Noble Liquids for High Energy Physics

    Energy Technology Data Exchange (ETDEWEB)

    Rebel, B. [Fermilab; Bernard, E. [Yale U.; Faham, C. H. [LBL, Berkeley; Ito, T. M. [Los Alamos; Lundberg, B. [Maryland U.; Messina, M. [Columbia U.; Monrabal, F. [Valencia U., IFIC; Pereverzev, S. P. [LLNL, Livermore; Resnati, F. [Zurich, ETH; Rowson, P. C. [SLAC; Soderberg, M. [Fermilab; Strauss, T. [Bern U.; Tomas, A. [Imperial Coll., London; Va' vra, J. [SLAC; Wang, H. [UCLA

    2014-08-22

    A workshop was held at Fermilab November 8-9, 2013 to discuss the challenges of using high voltage in noble liquids. The participants spanned the fields of neutrino, dark matter, and electric dipole moment physics. All presentations at the workshop were made in plenary sessions. This document summarizes the experiences and lessons learned from experiments in these fields at developing high voltage systems in noble liquids.

  16. Maintenance Optimization of High Voltage Substation Model

    Directory of Open Access Journals (Sweden)

    Radim Bris

    2008-01-01

    Full Text Available The real system from practice is selected for optimization purpose in this paper. We describe the real scheme of a high voltage (HV substation in different work states. Model scheme of the HV substation 22 kV is demonstrated within the paper. The scheme serves as input model scheme for the maintenance optimization. The input reliability and cost parameters of all components are given: the preventive and corrective maintenance costs, the actual maintenance period (being optimized, the failure rate and mean time to repair - MTTR.

  17. Zero voltage switching driver and flyback transformer for generation of atmospheric pressure plasma jet

    Science.gov (United States)

    Zin, Rosnah Mohd; Soon, Chin Fhong; Sani, Mohd Zuhri Ab; Rizon, Elfa Rizan; Tee, Kian Sek; Ahmad, Mohd Khairul; Ahmad, Nabihah@Nornabihah; Jubadi, Warsuzarina Mat; Nayan, Nafarizal

    2017-09-01

    There are increasing interests in the application of cold atmospheric plasma device for the application in surface science and medical field. Numerous studies focused on the effects of plasma emission onto living organisms. This report presents the application of a power driver circuit for induction of cold atmospheric plasma (CAP). The system consists of a resonant inverter of Zero Voltage Switching (ZVS) circuit powered by a 12Vdc input voltage which is coupled to a flyback transformer in generation of high voltage up to 24.5 kV. The output voltage from the ZVS driver and flyback transformer to the plasma torch (quartz tube) was determined using Falstad circuit simulation. The simulation on the waveforms generated from the ZVS circuit correlated well with the actual voltage measurement at the output of the ZVS circuit. The peak voltage dropped across a parallel capacitor coupled to the flyback transformer is approximately 36 V. The atmospheric pressure plasma jet (APPJ) purged with Argon gas at a flow rate of 50 l/min was exposed to a leaf for 5 seconds. This created pin holes in the exposed area of the leaf indicating high temperature was induced at the focused spot of the plasma. An atmospheric pressure plasma jet (APPJ) system has been developed for with potential application in destructive medicine.

  18. High Voltage GaN Schottky Rectifiers

    Energy Technology Data Exchange (ETDEWEB)

    CAO,X.A.; CHO,H.; CHU,S.N.G.; CHUO,C.-C.; CHYI,J.-I.; DANG,G.T.; HAN,JUNG; LEE,C.-M.; PEARTON,S.J.; REN,F.; WILSON,R.G.; ZHANG,A.P.

    1999-10-25

    Mesa and planar GaN Schottky diode rectifiers with reverse breakdown voltages (V{sub RB}) up to 550V and >2000V, respectively, have been fabricated. The on-state resistance, R{sub ON}, was 6m{Omega}{center_dot} cm{sup 2} and 0.8{Omega}cm{sup 2}, respectively, producing figure-of-merit values for (V{sub RB}){sup 2}/R{sub ON} in the range 5-48 MW{center_dot}cm{sup -2}. At low biases the reverse leakage current was proportional to the size of the rectifying contact perimeter, while at high biases the current was proportional to the area of this contact. These results suggest that at low reverse biases, the leakage is dominated by the surface component, while at higher biases the bulk component dominates. On-state voltages were 3.5V for the 550V diodes and {ge}15 for the 2kV diodes. Reverse recovery times were <0.2{micro}sec for devices switched from a forward current density of {approx}500A{center_dot}cm{sup -2} to a reverse bias of 100V.

  19. A High-Voltage Level Tolerant Transistor Circuit

    NARCIS (Netherlands)

    Annema, Anne J.; Geelen, Godefridus Johannes Gertrudis Maria

    2001-01-01

    A high-voltage level tolerant transistor circuit, comprising a plurality of cascoded transistors, including a first transistor (T1) operatively connected to a high-voltage level node (3) and a second transistor (T2) operatively connected to a low-voltage level node (2). The first transistor (T1)

  20. Prediction of breakdown voltages in novel gases for high voltage insulation

    Energy Technology Data Exchange (ETDEWEB)

    Koch, M.

    2015-07-01

    This thesis submitted to the Swiss Federal Institute of Technology ETH in Zurich examines the use of sulphur hexafluoride (SF{sub 6}) and similar gases as important insulation media for high voltage equipment. Due to its superior insulation properties, SF{sub 6} is widely used in gas-insulated switchgear. However, the gas also has a very high global warming potential and the content of SF{sub 6} in the atmosphere is constantly increasing. The search for new insulation gases using classical breakdown experiments is discussed. A model for SF{sub 6} based on the stepped leader model is described. This calculates the breakdown voltages in arbitrary electrode configurations and under standard voltage waveforms. Thus, the thesis provides a method for the prediction of breakdown voltages of arbitrary field configurations under standard voltage waveforms for gases with electron-attaching properties. With this, further gases can be characterized for usage as high voltage insulation media.

  1. High-Capacity, High-Voltage Composite Oxide Cathode Materials

    Science.gov (United States)

    Hagh, Nader M.

    2015-01-01

    This SBIR project integrates theoretical and experimental work to enable a new generation of high-capacity, high-voltage cathode materials that will lead to high-performance, robust energy storage systems. At low operating temperatures, commercially available electrode materials for lithium-ion (Li-ion) batteries do not meet energy and power requirements for NASA's planned exploration activities. NEI Corporation, in partnership with the University of California, San Diego, has developed layered composite cathode materials that increase power and energy densities at temperatures as low as 0 degC and considerably reduce the overall volume and weight of battery packs. In Phase I of the project, through innovations in the structure and morphology of composite electrode particles, the partners successfully demonstrated an energy density exceeding 1,000 Wh/kg at 4 V at room temperature. In Phase II, the team enhanced the kinetics of Li-ion transport and electronic conductivity at 0 degC. An important feature of the composite cathode is that it has at least two components that are structurally integrated. The layered material is electrochemically inactive; however, upon structural integration with a spinel material, the layered material can be electrochemically activated and deliver a large amount of energy with stable cycling.

  2. Small Distributed Renewable Energy Generation for Low Voltage Distribution Networks

    Directory of Open Access Journals (Sweden)

    Chindris M.

    2016-08-01

    Full Text Available Driven by the existing energy policies, the use of renewable energy has increased considerably all over the world in order to respond to the increasing energy consumption and to reduce the environmental impact of the electricity generation. Although most policy makers and companies are focusing on large applications, the use of cheap small generation units, based on local renewable resources, has become increasingly attractive for the general public, small farms and remote communities. The paper presents several results of a research project aiming to identify the power quality issues and the impact of RES based distributed generation (DG or other non-linear loads on low voltage (LV distribution networks in Romania; the final goal is to develop a Universal Power Quality Conditioner (UPQC able to diminish the existing disturbances. Basically, the work analyses the existing DG technologies and identifies possible solutions for their integration in Romania; taking into account the existent state of the art, the attention was paid on small systems, using wind and solar energy, and on possibility to integrate them into suburban and rural LV distribution networks. The presence of DG units at distribution voltage level means the transition from traditional passive to active distribution networks. In general, the relatively low penetration levels of DG does not produce problems; however, the nowadays massive increase of local power generation have led to new integration challenges in order to ensure the reliability and quality of the power supply. Power quality issues are identified and their assessment is the key element in the design of measures aiming to diminish all existing disturbances.

  3. RICH High Voltages & PDF Analysis @ LHCb

    CERN Multimedia

    Fanchini, E

    2009-01-01

    In the LHCb experiment an important issue is the identification of the hadrons of the final states of the B mesons decays. Two RICH subdetectors are devoted to this task, and the Hybrid Photon Detectors (HPDs) are the photodetectors used to detect Cherenkov light. In this poster there is a description of how the very high voltage (-18 KV) supply stability used to power the HPDs is monitored. It is also presented the basics of a study which can be done with the first collision data: the analysis of the dimuons from the Drell-Yan process. This process is well known and the acceptance of the LHCb detector in terms of pseudorapidity will be very useful to improve the knowledge of the proton structure functions or, alternatively, try to estimate the luminosity from it.

  4. Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients. Initial experience with 3{sup rd} generation dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Hagelstein, Claudia; Henzler, Thomas; Haubenreisser, Holger; Meyer, Mathias; Sudarski, Sonja; Schoenberg, Stefan O.; Neff, K. Wolfgang; Weis, Meike [Univ. Medical Center Mannheim (Germany). Inst. of Clinical Radiology and Nuclear Medicine

    2016-07-01

    Minimizing radiation dose while at the same time preserving image quality is of particular importance in pediatric chest CT. Very recently, CT imaging with a tube voltage of 70 kVp has become clinically available. However, image noise is inversely proportional to the tube voltage. We aimed to investigate radiation dose and image quality of pediatric chest CT performed at 70 kVp in an anthropomorphic pediatric phantom as well as in clinical patients. An anthropomorphic pediatric phantom, which resembles a one-year-old child in physiognomy, was scanned on the 3{sup rd} generation dual-source CT (DSCT) system at 70 kVp and 80 kVp and a fixed ultra low tube-current of 8 mAs to solely evaluate the impact of lowering tube voltage. After the phantom measurements, 18 pediatric patients (mean 29.5 months; range 1-91 months; 21 examinations) underwent 3.2 high-pitch chest CT on the same DSCT system at 70 kVp tube voltage without any sedation. Radiation dose and presence of motion artifacts was compared to a retrospectively identified patient cohort examined at 80 kVp on a 16-slice single-source-CT (SSCT; n = 15; 14/15 with sedation; mean 30.7 months; range 0-96 months; pitch = 1.5) or on a 2{sup nd} generation DSCT without any sedation (n = 6; mean 32.8 months; range 4-61 months; pitch = 3.2). Radiation dose in the phantom scans was reduced by approximately 40% when using a tube voltage of 70 kVp instead of 80 kVp. In the pediatric patient group examined at 70 kVp age-specific effective dose (ED; mean 0.5 ± 0.2 mSv) was significantly lower when compared to the retrospective cohort scanned at 80 kVp on the 16-slice-SSCT (mean ED: 1.0 ± 0.3 mSv; p < 0.0001) and also considerably lower when compared to the cohort scanned at 80 kVp on the 2{sup nd} generation DSCT (mean ED: 0.9 ± 0.5 mSv). None of the prospective, sedation-free CT examinations showed any motion artifacts whereas 13/15 examinations of the retrospective patient cohort scanned at 80 kVp with a pitch of 1

  5. Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients: Initial experience with 3(rd) generation dual-source CT.

    Science.gov (United States)

    Hagelstein, Claudia; Henzler, Thomas; Haubenreisser, Holger; Meyer, Mathias; Sudarski, Sonja; Schoenberg, Stefan O; Neff, K Wolfgang; Weis, Meike

    2016-12-01

    Minimizing radiation dose while at the same time preserving image quality is of particular importance in pediatric chest CT. Very recently, CT imaging with a tube voltage of 70 kVp has become clinically available. However, image noise is inversely proportional to the tube voltage. We aimed to investigate radiation dose and image quality of pediatric chest CT performed at 70 kVp in an anthropomorphic pediatric phantom as well as in clinical patients. An anthropomorphic pediatric phantom, which resembles a one-year-old child in physiognomy, was scanned on the 3(rd) generation dual-source CT (DSCT) system at 70 kVp and 80 kVp and a fixed ultra low tube-current of 8 mAs to solely evaluate the impact of lowering tube voltage. After the phantom measurements, 18 pediatric patients (mean 29.5 months; range 1-91 months; 21 examinations) underwent 3.2 high-pitch chest CT on the same DSCT system at 70 kVp tube voltage without any sedation. Radiation dose and presence of motion artifacts was compared to a retrospectively identified patient cohort examined at 80 kVp on a 16-slice single-source-CT (SSCT; n=15; 14/15 with sedation; mean 30.7 months; range 0-96 months; pitch=1.5) or on a 2(nd) generation DSCT without any sedation (n=6; mean 32.8 months; range 4-61 months; pitch=3.2). Radiation dose in the phantom scans was reduced by approximately 40% when using a tube voltage of 70 kVp instead of 80 kVp. In the pediatric patient group examined at 70 kVp age-specific effective dose (ED; mean 0.5±0.2 mSv) was significantly lower when compared to the retrospective cohort scanned at 80 kVp on the 16-slice-SSCT (mean ED: 1.0±0.3 mSv; p<0.0001) and also considerably lower when compared to the cohort scanned at 80 kVp on the 2(nd) generation DSCT (mean ED: 0.9±0.5 mSv). None of the prospective, sedation-free CT examinations showed any motion artifacts whereas 13/15 examinations of the retrospective patient cohort scanned at 80 kVp with a pitch of 1.5 showed motion artifacts. 3.2 high

  6. Study on cathode high voltage pulse control in image intensifier

    Science.gov (United States)

    Yang, Ye; Yan, Bo; Ni, Xiao-bing; Zhi, Qiang; Li, Jun-guo; Yao, Ze; Deng, Guang-xu

    2016-03-01

    This paper briefly introduces the basic working principle of auto-gating power source. Due to the presence of noise in the circuit, the cathode pulse signal generated by the AD converter is unstable. In this paper, the circuit of the AD converter is adjusted to improve the instability of the cathode high voltage pulse signal, especially in the case of low light and high illumination to avoid the jitter of the pulse. The experiment was carried out. And it could guide the implementation of this part of the circuit.

  7. Bottlenecks reduction using superconductors in high voltage transmission lines

    Directory of Open Access Journals (Sweden)

    Daloub Labib

    2016-01-01

    Full Text Available Energy flow bottlenecks in high voltage transmission lines known as congestions are one of the challenges facing power utilities in fast developing countries. Bottlenecks occur in selected power lines when transmission systems are operated at or beyond their transfer limits. In these cases, congestions result in preventing new power supply contracts, infeasibility in existing contracts, price spike and market power abuse. The “Superconductor Technology” in electric power transmission cables has been used as a solution to solve the problem of bottlenecks in energy transmission at high voltage underground cables and overhead lines. The increase in demand on power generation and transmission happening due to fast development and linked to the intensive usage of transmission network in certain points, which in turn, lead to often frequent congestion in getting the required power across to where it is needed. In this paper, a bottleneck in high voltage double overhead transmission line with Aluminum Conductor Steel Reinforced was modeled using conductor parameters and replaced by Gap-Type Superconductor to assess the benefit of upgrading to higher temperature superconductor and obtain higher current carrying capacity. This proved to reduce the high loading of traditional aluminum conductors and allow more power transfer over the line using superconductor within the same existing right-of-way, steel towers, insulators and fittings, thus reducing the upgrade cost of building new lines.

  8. External loading of High Voltage Pylons

    Directory of Open Access Journals (Sweden)

    Peter Polák

    2013-12-01

    Full Text Available This contribution is devoted to issues of long term safe service of high-voltage pylons, which are loaded during service by variable loading with simultaneous acting of external environment. There were proved the procedures ensuring that the limit state will not occur during the period of technical life and the service will be safe for a long time. A draft of diagnostic procedures was elaborated, applied in suitable inspection intervals, following from the analysis of failure risks. The maintenance and repair procedures, assuring the safety of service until next inspection are planned on the basis of application of analytic methods of dynamic fracture mechanics. This procedure of controlled ageing is designed for the new and serviced pylons as well. The controlled ageing at the same time prolongs the technical life of structure with a high measure of safety. Residual life can be determined in each phase of pylon life. Controlled ageing allows saving high economic values at spending considerable lower costs for inspection and maintenance.

  9. Generation of large-scale, barrier-free diffuse plasmas in air at atmospheric pressure using array wire electrodes and nanosecond high-voltage pulses

    Science.gov (United States)

    Teng, Yun; Li, Lee; Liu, Yun-Long; Liu, Lun; Liu, Minghai

    2014-10-01

    This paper introduces a method to generate large-scale diffuse plasmas by using a repetition nanosecond pulse generator and a parallel array wire-electrode configuration. We investigated barrier-free diffuse plasmas produced in the open air in parallel and cross-parallel array line-line electrode configurations. We found that, when the distance between the wire-electrode pair is small, the discharges were almost extinguished. Also, glow-like diffuse plasmas with little discharge weakening were obtained in an appropriate range of line-line distances and with a cathode-grounding cross-electrode configuration. As an example, we produced a large-scale, stable diffuse plasma with volumes as large as 18 × 15 × 15 cm3, and this discharge region can be further expanded. Additionally, using optical and electrical measurements, we showed that the electron temperature was higher than the gas temperature, which was almost the same as room temperature. Also, an array of electrode configuration with more wire electrodes had helped to prevent the transition from diffuse discharge to arc discharge. Comparing the current waveforms of configurations with 1 cell and 9 cells, we found that adding cells significantly increased the conduction current and the electrical energy delivered in the electrode gaps.

  10. Design and development of high voltage high power operational ...

    Indian Academy of Sciences (India)

    systems and the electron deflection systems. Power operational amplifiers have ... approach is cost and availability of high voltage devices in chip form. 2.2 Amplifier with opamp input stage .... power opamp, using chip passive components, semiconductor bare dice minimizes the size while increasing the reliability.

  11. Application of Load Compensation in Voltage Controllers of Large Generators in the Polish Power Grid

    Directory of Open Access Journals (Sweden)

    Bogdan Sobczak

    2014-03-01

    Full Text Available The Automatic Voltage Regulator normally controls the generator stator terminal voltage. Load compensation is used to control the voltage which is representative of the voltage at a point either within or external to the generator. In the Polish Power Grid (PPG compensation is ready to use in every AVR of a large generator, but it is utilized only in the case of generators operating at the same medium voltage buses. It is similar as in most European Power Grids. The compensator regulating the voltage at a point beyond the machine terminals has significant advantages in comparison to the slower secondary Voltage and Reactive Power Control System (ARNE1. The compensation stiffens the EHV grid, which leads to improved voltage quality in the distribution grid. This effect may be particularly important in the context of the dynamic development of wind and solar energy.

  12. Low-voltage and high-voltage TEM observations on MWCNTs of rat in vivo.

    Science.gov (United States)

    Sakaguchi, Norihito; Watari, Fumio; Yokoyama, Atsuro; Nodasaka, Yoshinobu; Ichinose, Hideki

    2009-01-01

    In the present study, we focused on the optimal conditions for observation of morphology and atomic structure of carbon nanotube (CNT) in vivo by transmission electron microscopy (TEM). Either low-voltage or high-voltage TEMs was chosen for the high-contrast or high-resolution imaging of subcutaneous tissue and the multi-wall CNT (MWCNT). The morphology and structure of each cell organelle were well recognized using the low-voltage TEM at 75 kV. Individual MWCNTs forming the cluster were also visible by the low-voltage TEM. On the contrary, the high-voltage TEM image at 1250 kV shows poor contrast on both the cell organelles and MWCNTs. However, graphene layers of MWCNT were clearly visible in the HRTEM image using the high-voltage TEM. The influence of the surrounding biological tissue can be disregarded by the high-energy electrons due to their weak scattering/absorption effect in the tissue. It was indicated that the usage of the high-voltage TEM is quite effective to the atomic structure analysis of nano-crystalline materials in vivo.

  13. LED-Based High-Voltage Lines Warning System

    Directory of Open Access Journals (Sweden)

    Eldar MUSA

    2013-04-01

    Full Text Available LED-based system, running with the current of high-voltage lines and converting the current flowing through the line into the light by using a toroid transformer, has been developed. The transformer’s primary winding is constituted by the high voltage power line. Toroidal core consists of two equal parts and the secondary windings are evenly placed on these two parts. The system is mounted on the high-voltage lines as a clamp. The secondary winding ends are connected in series by the connector on the clamp. LEDs are supplied by the voltage at the ends of secondary. Current flowing through highvoltage transmission lines is converted to voltage by the toroidal transformer and the light emitting LEDs are supplied with this voltage. The theory of the conversion of the current flowing through the line into the light is given. The system, running with the current of the line and converting the current into the light, has been developed. System has many application areas such as warning high voltage lines (warning winches to not hinder the high-voltage lines when working under the lines, warning planes to not touch the high-voltage lines, remote measurement of high-voltage line currents, and local illumination of the line area

  14. High Voltage Application of Explosively Formed Fuses

    Energy Technology Data Exchange (ETDEWEB)

    Tasker, D.G.; Goforth, J.H.; Fowler, C.M.; Lopez, E.M.; Oona, H.; Marsh, S.P.; King, J.C.; Herrera, D.H.; Torres, D.T.; Sena, F.C.; Martinez, E.C.; Reinovsky, R.E.; Stokes, J.L.; Tabaka, L.J.; Kiuttu, G.; Degnan, J.

    1998-10-18

    At Los Alamos, the authors have primarily applied Explosively Formed Fuse (EFF) techniques to high current systems. In these systems, the EFF has interrupted currents from 19 to 25 MA, thus diverting the current to low inductance loads. The magnitude of transferred current is determined by the ratio of storage inductance to load inductance, and with dynamic loads, the current has ranged from 12 to 20 MA. In a system with 18 MJ stored energy, the switch operates at a power up to 6 TW. The authors are now investigating the use of the EFF technique to apply high voltages to high impedance loads in systems that are more compact. In these systems, they are exploring circuits with EFF lengths from 43 to 100 cm, which have storage inductances large enough to apply 300 to 500 kV across high impedance loads. Experimental results and design considerations are presented. Using cylindrical EFF switches of 10 cm diameter and 43 cm length, currents of approximately 3 MA were interrupted producing {approximately}200 kV. This indicate s the switch had an effective resistance of {approximately}100 m{Omega} where 150--200 m{Omega} was expected. To understand the lower performance, several parameters were studied, including: electrical conduction through the explosive products; current density; explosive initiation; insulator type; conductor thickness; and so on. The results show a number of interesting features, most notably that the primary mechanism of switch operation is mechanical and not electrical fusing of the conductor. Switches opening on a 10 to 10 {micro}s time scale with resistances starting at 50 {micro}{Omega} and increasing to perhaps 1 {Omega} now seem possible to construct, using explosive charges as small as a few pounds.

  15. Flexible voltage support control for three-phase distributed generation inverters under grid fault

    DEFF Research Database (Denmark)

    Camacho, Antonio; Castilla, Miguel; Miret, Jaume

    2013-01-01

    Operators describe the behavior of the energy source, regulating voltage limits and reactive power injection to remain connected and support the grid under fault. On the basis that different kinds of voltage sags require different voltage support strategies, a flexible control scheme for three phase grid...... connected inverters is proposed. In three phase balanced voltage sags, the inverter should inject reactive power in order to raise the voltage in all phases. In one or two phase faults, the main concern of the distributed generation inverter is to equalize voltages by reducing the negative symmetric...... of this work is the introduction of a control algorithm for reference current generation that provides flexible voltage support under grid faults. Two different voltage sags have been experimentally tested to illustrate the behavior of the proposed voltage support control scheme....

  16. Artificial neural networks in high voltage transmission line problems

    Science.gov (United States)

    Ekonomou, L.; Kontargyri, V. T.; Kourtesi, St.; Maris, T. I.; Stathopulos, I. A.

    2007-07-01

    According to the literature high voltage transmission line problems are faced using conventional analytical methods, which include in most cases empirical and/or approximating equations. Artificial intelligence and more specifically artificial neural networks (ANN) are addressed in this work, in order to give accurate solutions to high voltage transmission line problems using in the calculations only actual field data. Two different case studies are studied, i.e., the estimation of critical flashover voltage on polluted insulators and the estimation of lightning performance of high voltage transmission lines. ANN models are developed and are tested on operating high voltage transmission lines and polluted insulators, producing very satisfactory results. These two ANN models can be used in electrical engineers' studies aiming at the more effective protection of high voltage equipment.

  17. Nitrogen doping effect on flow-induced voltage generation from graphene-water interface

    Science.gov (United States)

    Okada, Takeru; Kalita, Golap; Tanemura, Masaki; Yamashita, Ichiro; Meyyappan, M.; Samukawa, Seiji

    2018-01-01

    Liquid-flow-induced generation of electricity using nanocarbons, particularly graphene-water interface, has received attention for energy harvesting. Here, we have obtained voltage generation from a single water droplet motion on graphene. We have investigated the effect of the graphene surface condition on flow-induced voltage generation, which is controlled by heteroatom doping. Nitrogen-doped graphene shows three times higher voltage generation compared to pristine graphene due to the doping-induced surface charge of graphene. Graphene surface potential tuning by doping is shown to play an important role in voltage generation.

  18. Real-time transient stabilization and voltage regulation of power generators with unknown mechanical power input

    Energy Technology Data Exchange (ETDEWEB)

    Kenne, Godpromesse, E-mail: gokenne@yahoo.co [Laboratoire d' Automatique et d' Informatique Appliquee (LAIA), Departement de Genie Electrique, Universite de Dschang, B.P. 134 Bandjoun (Cameroon); Goma, Raphael, E-mail: raphael.goma@lss.supelec.f [Laboratoire des Signaux et Systemes (L2S), CNRS-SUPELEC, Universite Paris XI, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France); Nkwawo, Homere, E-mail: homere.nkwawo@iutv.univ-paris13.f [Departement GEII, Universite Paris XIII, 99 Avenue Jean Baptiste Clement, 93430 Villetaneuse (France); Lamnabhi-Lagarrigue, Francoise, E-mail: lamnabhi@lss.supelec.f [Laboratoire des Signaux et Systemes (L2S), CNRS-SUPELEC, Universite Paris XI, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France); Arzande, Amir, E-mail: Amir.arzande@supelec.f [Departement Energie, Ecole Superieure d' Electricite-SUPELEC, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France); Vannier, Jean Claude, E-mail: Jean-claude.vannier@supelec.f [Departement Energie, Ecole Superieure d' Electricite-SUPELEC, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France)

    2010-01-15

    A nonlinear adaptive excitation controller is proposed to enhance the transient stability and voltage regulation of synchronous generators with unknown power angle and mechanical power input. The proposed method is based on a standard third-order model of a synchronous generator which requires only information about the physical available measurements of relative angular speed, active electric power, infinite bus and generator terminal voltages. The operating conditions are computed online using the above physical available measurements, the terminal voltage reference value and the estimate of the mechanical power input. The proposed design is therefore capable of providing satisfactory voltage in the presence of unknown variations of the power system operating conditions. Using the concept of sliding mode equivalent control techniques, a robust decentralized adaptive controller which insures the exponential convergence of the outputs to the desired ones, is obtained. Real-time experimental results are reported, comparing the performance of the proposed adaptive nonlinear control scheme to one of the conventional AVR/PSS controller. The high simplicity of the overall adaptive control scheme and its robustness with respect to line impedance variation including critical unbalanced operating condition and temporary turbine fault, constitute the main positive features of the proposed approach.

  19. Study of Low Voltage Ride Through Performance for Wind Power Generation with Doubly Fed Induction Generator

    Science.gov (United States)

    Hirawata, Ryoya; Kai, Takaaki

    Recently, the introduction of wind power generation is increasing rapidly. The ratio of wind power generation to the capacity of a total generation is getting higher and higher. When the phase-to-phase fault occurs in the power system, the frequency of power system is lower due to disconnecting of the wind power generation with doubly fed induction generator (DFIG). Therefore, the power system might become unstable. This paper describes the LVRT (low voltage ride through) performance improvement scheme of the wind power generation with DFIG. The wind power generation is disconnected from the grid in case of the power system fault. It is independently in operation from the grid by controlling of the inverter equipped in the generation. After clearance of the power system fault, the wind power generation is immediately re-connected to the grid. As a result, instability in the power system disappears. The performance of LVRT is confirmed by using simulation software PSCAD/EMTDC. The simulation result shows an excellent result to the three-phase short-circuit fault of the voltage dip 100%.

  20. ON SELECTION OF CIRCUIT-BREAKERS SWITCHING ELECTRICAL INSTALLATIONS OF HIGH AND EXTRA-HIGH VOLTAGE

    Directory of Open Access Journals (Sweden)

    T. M. Lazimov

    2005-01-01

    Full Text Available The paper proposes some additional conditions for high-voltage circuit-breaker selection keeping in mind coordination of the switched over-voltages and voltages induced in secondary circuits with their permissible values.

  1. Voltage Control Support and Coordination between Renewable Generation Plants in MV Distribution Systems

    DEFF Research Database (Denmark)

    Petersen, Lennart; Iov, Florin; D. Hansen, Anca

    2016-01-01

    This paper focusses on voltage control support and coordination between renewable generation plants in medium voltage distribution systems. An exemplary benchmark grid in Denmark, including a number of flexible ReGen plants providing voltage control functionality, is used as a base case. First...

  2. High voltage switches having one or more floating conductor layers

    Science.gov (United States)

    Werne, Roger W.; Sampayan, Stephen; Harris, John Richardson

    2015-11-24

    This patent document discloses high voltage switches that include one or more electrically floating conductor layers that are isolated from one another in the dielectric medium between the top and bottom switch electrodes. The presence of the one or more electrically floating conductor layers between the top and bottom switch electrodes allow the dielectric medium between the top and bottom switch electrodes to exhibit a higher breakdown voltage than the breakdown voltage when the one or more electrically floating conductor layers are not present between the top and bottom switch electrodes. This increased breakdown voltage in the presence of one or more electrically floating conductor layers in a dielectric medium enables the switch to supply a higher voltage for various high voltage circuits and electric systems.

  3. BACK TO BACK VOLTAGE SOURCE INVERTER FOR CONTROL OF SELF EXCITED INDUCTION GENERATOR

    Directory of Open Access Journals (Sweden)

    Ainur Rachmad Hidayat

    2017-01-01

    Full Text Available Wind is one of the most develop renewable energy to help human meet the electricity needs as availability is abundant. Instrument which can be used to convert wind energy into electrical energy is an induction generator. In this final project will discuss about the operation of the wind turbine with induction generator controlled using back to back voltage source inverter with grid connected system low voltage 380 V. Switching of back to back voltage source inverter was designed in average model.In back to back voltage source inverter, there are two converters that are machine side converter and grid side converter. Machine side converter has function to regulate the voltage and frequency of generator and turbine speed in order to the wind turbine can generate maximum power at any wind speed with method volt / hetrz constant control. Grid side converter has function to adjust the DC voltage keep be contant by synchronizing the phase angle between the converter output and grid using current controlled voltage source inverter method.The simulation results showed that wind turbine always generated the maximum power at any wind speed. Voltage and frequency of Generator is stable and directly proportional to the wind speed and the dc link voltage is always constant so the power flow can bidirectional. Therefore, back-to-back voltage source inverter is suitable for controlling wind turbine using an induction generator.  

  4. Integrated reconfigurable high-voltage transmitting circuit for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Jørgensen, Ivan Harald Holger

    2015-01-01

    In this paper a high-voltage transmitting circuit aimed for capacitive micromachined ultrasonic transducers (CMUTs) used in scanners for medical applications is designed and implemented in a 0.35 μm high-voltage CMOS process. The transmitting circuit is reconfigurable externally making it able...

  5. Collapse of a cavitation bubble generated by low voltage discharge in water

    Directory of Open Access Journals (Sweden)

    Zima Patrik

    2012-04-01

    Full Text Available The article presents experimental results of the optical study of cavitation bubble collapse close to a solid boundary in water. The bubble was generated by discharge of two low-voltage capacitors. High-speed CCD camera was used to record the time evolution of the bubble size. High-power halogen lamp was used for illumination. The system was synchronized by pulse generator connected to an oscilloscope. The velocity of the re-entrant jet was estimated from the time resolved photography for different maximum bubble sizes.

  6. PV source based high voltage gain current fed converter

    Science.gov (United States)

    Saha, Soumya; Poddar, Sahityika; Chimonyo, Kudzai B.; Arunkumar, G.; Elangovan, D.

    2017-11-01

    This work involves designing and simulation of a PV source based high voltage gain, current fed converter. It deals with an isolated DC-DC converter which utilizes boost converter topology. The proposed converter is capable of high voltage gain and above all have very high efficiency levels as proved by the simulation results. The project intends to produce an output of 800 V dc from a 48 V dc input. The simulation results obtained from PSIM application interface were used to analyze the performance of the proposed converter. Transformer used in the circuit steps up the voltage as well as to provide electrical isolation between the low voltage and high voltage side. Since the converter involves high switching frequency of 100 kHz, ultrafast recovery diodes are employed in the circuitry. The major application of the project is for future modeling of solar powered electric hybrid cars.

  7. Multiple High Voltage Pulse Stressing of Polymer Thick Film Resistors

    Directory of Open Access Journals (Sweden)

    Busi Rambabu

    2014-01-01

    Full Text Available The purpose of this paper is to study high voltage interactions in polymer thick film resistors, namely, polyvinyl chloride- (PVC- graphite thick film resistors, and their applications in universal trimming of these resistors. High voltages in the form of impulses for various pulse durations and with different amplitudes have been applied to polymer thick film resistors and we observed the variation of resistance of these resistors with high voltages. It has been found that the resistance of polymer thick film resistors decreases in the case of higher resistivity materials and the resistance of polymer thick film resistor increases in the case of lower resistivity materials when high voltage impulses are applied to them. It has been also found that multiple high voltage pulse (MHVP stressing can be used to trim the polymer thick film resistors either upwards or downwards.

  8. High Voltage Installation of PS Linac 1 Preinjector

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    The high-voltage installation of the linac 1 preinjector in its house-sized Faraday cage. Originally driven by a 520 kV Cockcroft-Walton generator, at the time of this picture the HV came from a 520 kV SAMES generator. The column in the front carries a capacitor. The cubicle in the right background is the electronics platform (see 7403120). The round structure at left houses the ion source, from where the protons (and sometimes other ions), electrostatically accelerated to 520 keV, enter the Alvarez structure of linac 1, to be accelerated to 50 MeV. Jean-Luc Vallet is busy with servicing the installation. See also 7403064X, 7403066X.

  9. Recycling potential for low voltage and high voltage high rupturing capacity fuse links.

    Science.gov (United States)

    Psomopoulos, Constantinos S; Barkas, Dimitrios A; Kaminaris, Stavros D; Ioannidis, George C; Karagiannopoulos, Panagiotis

    2017-12-01

    Low voltage and high voltage high-rupturing-capacity fuse links are used in LV and HV installations respectively, protecting mainly the LV and HV electricity distribution and transportation networks. The Waste Electrical and Electronic Equipment Directive (2002/96/EC) for "Waste of electrical and electronic equipment" is the main related legislation and as it concerns electrical and electronic equipment, it includes electric fuses. Although, the fuse links consist of recyclable materials, only small scale actions have been implemented for their recycling around Europe. This work presents the possibilities for material recovery from this specialized industrial waste for which there are only limited volume data. Furthermore, in order to present the huge possibilities and environmental benefits, it presents the potential for recycling of HRC fuses used by the Public Power Corporation of Greece, which is the major consumer for the country, but one of the smallest ones in Europe and globally, emphasizing in this way in the issue. According to the obtained results, fuse recycling could contribute to the effort for minimize the impacts on the environment through materials recovery and reduction of the wastes' volume disposed of in landfills. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. High voltage bus and auxiliary heater control system for an electric or hybrid vehicle

    Science.gov (United States)

    Murty, Balarama Vempaty

    2000-01-01

    A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

  11. Properties of Polymer Composites Used in High-Voltage Applications

    Directory of Open Access Journals (Sweden)

    Ilona Pleşa

    2016-04-01

    Full Text Available The present review article represents a comprehensive study on polymer micro/nanocomposites that are used in high-voltage applications. Particular focus is on the structure-property relationship of composite materials used in power engineering, by exploiting fundamental theory as well as numerical/analytical models and the influence of material design on electrical, mechanical and thermal properties. In addition to describing the scientific development of micro/nanocomposites electrical features desired in power engineering, the study is mainly focused on the electrical properties of insulating materials, particularly cross-linked polyethylene (XLPE and epoxy resins, unfilled and filled with different types of filler. Polymer micro/nanocomposites based on XLPE and epoxy resins are usually used as insulating systems for high-voltage applications, such as: cables, generators, motors, cast resin dry-type transformers, etc. Furthermore, this paper includes ample discussions regarding the advantages and disadvantages resulting in the electrical, mechanical and thermal properties by the addition of micro- and nanofillers into the base polymer. The study goals are to determine the impact of filler size, type and distribution of the particles into the polymer matrix on the electrical, mechanical and thermal properties of the polymer micro/nanocomposites compared to the neat polymer and traditionally materials used as insulation systems in high-voltage engineering. Properties such as electrical conductivity, relative permittivity, dielectric losses, partial discharges, erosion resistance, space charge behavior, electric breakdown, tracking and electrical tree resistance, thermal conductivity, tensile strength and modulus, elongation at break of micro- and nanocomposites based on epoxy resin and XLPE are analyzed. Finally, it was concluded that the use of polymer micro/nanocomposites in electrical engineering is very promising and further research work

  12. Optically triggered high voltage switch network and method for switching a high voltage

    Science.gov (United States)

    El-Sharkawi, Mohamed A.; Andexler, George; Silberkleit, Lee I.

    1993-01-19

    An optically triggered solid state switch and method for switching a high voltage electrical current. A plurality of solid state switches (350) are connected in series for controlling electrical current flow between a compensation capacitor (112) and ground in a reactive power compensator (50, 50') that monitors the voltage and current flowing through each of three distribution lines (52a, 52b and 52c), which are supplying three-phase power to one or more inductive loads. An optical transmitter (100) controlled by the reactive power compensation system produces light pulses that are conveyed over optical fibers (102) to a switch driver (110') that includes a plurality of series connected optical triger circuits (288). Each of the optical trigger circuits controls a pair of the solid state switches and includes a plurality of series connected resistors (294, 326, 330, and 334) that equalize or balance the potential across the plurality of trigger circuits. The trigger circuits are connected to one of the distribution lines through a trigger capacitor (340). In each switch driver, the light signals activate a phototransistor (300) so that an electrical current flows from one of the energy reservoir capacitors through a pulse transformer (306) in the trigger circuit, producing gate signals that turn on the pair of serially connected solid state switches (350).

  13. Second and third generation voltage-sensitive fluorescent proteins for monitoring membrane potential

    Directory of Open Access Journals (Sweden)

    Amelie Perron

    2009-06-01

    Full Text Available Over the last decade, optical neuroimaging methods have been enriched by engineered biosensors derived from fluorescent protein (FP reporters fused to protein detectors that convert physiological signals into changes of intrinsic FP fluorescence. These FP-based indicators are genetically encoded, and hence targetable to specific cell populations within networks of heterologous cell types. Among this class of biosensors, the development of optical probes for membrane potential is both highly desirable and challenging. A suitable FP voltage sensor would indeed be a valuable tool for monitoring the activity of thousands of individual neurons simultaneously in a non-invasive manner. Previous prototypic genetically-encoded FP voltage indicators achieved a proof of principle but also highlighted several difficulties such as poor cell surface targeting and slow kinetics. Recently, we developed a new series of FRET-based Voltage-Sensitive Fluorescent Proteins (VSFPs, referred to as VSFP2s, with efficient targeting to the plasma membrane and high responsiveness to membrane potential signaling in excitable cells. In addition to these FRET-based voltage sensors, we also generated a third series of probes consisting of single FPs with response kinetics suitable for the optical imaging of fast neuronal signals. These newly available genetically-encoded reporters for membrane potential will be instrumental for future experimental approaches directed toward the understanding of neuronal network dynamics and information processing in the brain. Here, we review the development and current status of these novel fluorescent probes.

  14. Survey of high voltage electron microscopy worldwide in 1998.

    Energy Technology Data Exchange (ETDEWEB)

    Allen, C. W.

    1998-03-05

    High voltage TEMs were introduced commercially thirty years ago, with the installations of 500 kV Hitachi instruments at the Universities of Nagoya and Tokyo. Since that time 53 commercial instruments, having maximum accelerating potentials of 0.5-3.5 MV, will have been delivered by the end of 1998. Table 1 summarizes the sites and some information regarding those HVEMS which are available in 1998. This corrects, updates and expands an earlier report of this sort [2]. There have been three commercial HVEM manufacturers: AEI (UK), Hitachi and JEOL (Japan). The proportion of the total number of HVEMS produced by each manufacturer is similar to that reflected in Table 1: AEI and Kratos/AEI (12), Hitachi (20) and JEOL (21). The term Kratos/AEI refers to instruments delivered after the takeover of AEI by Grates in the late 1970's. In Table 1 only maximum accelerating potentials are listed, which is generally also the design value for which the resolution for imaging was optimized. It is important to realize that in many applications, especially those studying irradiation effects, much lower voltages may be employed somewhat routinely to minimize atom displacements by the incident electron beam during analysis. These minimum values range from 100 kV for the AEI and Kratos/AEI instruments to typically 400 kV for the current generation of atomic resolution instruments, the latter being well above the thresholds for displacement in light elements such as Al and Si and for displacement of anions in many ceramic materials such as the high Tc superconductors, for example. An additional potential problem is electron-induced sputtering and differential sputtering (unequal sputtering rates in multicomponent materials), especially when accurate elemental microanalysis is being attempted. These same issues may arise for intermediate voltage TEMs as well, of course.

  15. Voltage-Mode Four-Phase Sinusoidal Generator and Its Useful Extensions

    Directory of Open Access Journals (Sweden)

    Sudhanshu Maheshwari

    2013-01-01

    Full Text Available This paper introduces a new voltage-mode second-order sinusoidal generator circuit with four active elements and six passive elements, including grounded capacitors. The frequency and condition of oscillation can be independently controlled. The effect of active element’s nonidealities and parasitic effects is also studied; the proposed topology is good in absorbing several parasitic elements involved with the active elements. The circuit is advantageous for generating high frequency signals which is demonstrated for 25 MHz outputs. Several circuit extensions are also given which makes the new proposal useful for real circuit adoption. The proposed theory is validated through simulation results.

  16. Phononic High Harmonic Generation

    OpenAIRE

    Ganesan, Adarsh; Do, Cuong; Seshia, Ashwin A.

    2016-01-01

    This paper reports the first experimental evidence for phononic low-order to high-order harmonic conversion leading to high harmonic generation. Similar to parametric resonance, phononic high harmonic generation is also mediated by a threshold dependent instability of a driven phonon mode. Once the threshold for instability is met, a cascade of harmonic generation processes is triggered. Firstly, the up-conversion of first harmonic phonons into second harmonic phonons is established. Subseque...

  17. High voltage high repetition rate pulse using Marx topology

    Science.gov (United States)

    Hakki, A.; Kashapov, N.

    2015-06-01

    The paper describes Marx topology using MOSFET transistors. Marx circuit with 10 stages has been done, to obtain pulses about 5.5KV amplitude, and the width of the pulses was about 30μsec with a high repetition rate (PPS > 100), Vdc = 535VDC is the input voltage for supplying the Marx circuit. Two Ferrite ring core transformers were used to control the MOSFET transistors of the Marx circuit (the first transformer to control the charging MOSFET transistors, the second transformer to control the discharging MOSFET transistors).

  18. Mechanical Properties of Composites Used in High-Voltage Applications

    Directory of Open Access Journals (Sweden)

    Andreas Moser

    2016-07-01

    Full Text Available Materials used in high voltage applications have to meet a lot of regulations for their safety and functional usage during their lifetime. For high voltage applications the electrical properties are the most relevant designing criteria. However, the mechanical properties of such materials have rarely been considered for application dimensioning over the last decades. This article gives an overview of composite materials used in high voltage applications and some basic mechanical and thermo-mechanical characterization methods of such materials, including a discussion of influences on practically used epoxy based thermosets.

  19. Process engineering of high voltage alginate encapsulation of mesenchymal stem cells

    Energy Technology Data Exchange (ETDEWEB)

    Gryshkov, Oleksandr, E-mail: gryshkov@imp.uni-hannover.de [Institute for Multiphase Processes, Leibniz University Hannover, D-30167 Hannover (Germany); Pogozhykh, Denys, E-mail: pogozhykh@imp.uni-hannover.de [Institute for Multiphase Processes, Leibniz University Hannover, D-30167 Hannover (Germany); Zernetsch, Holger, E-mail: zernetsch@imp.uni-hannover.de [Institute for Multiphase Processes, Leibniz University Hannover, D-30167 Hannover (Germany); Hofmann, Nicola, E-mail: hofmann@imp.uni-hannover.de [Institute for Multiphase Processes, Leibniz University Hannover, D-30167 Hannover (Germany); Mueller, Thomas, E-mail: mueller.thomas@mh-hannover.de [Institute for Transfusion Medicine, Medical School Hannover, D-30625 Hannover (Germany); Glasmacher, Birgit, E-mail: glasmacher@imp.uni-hannover.de [Institute for Multiphase Processes, Leibniz University Hannover, D-30167 Hannover (Germany)

    2014-03-01

    Encapsulation of stem cells in alginate beads is promising as a sophisticated drug delivery system in treatment of a wide range of acute and chronic diseases. However, common use of air flow encapsulation of cells in alginate beads fails to produce beads with narrow size distribution, intact spherical structure and controllable sizes that can be scaled up. Here we show that high voltage encapsulation (≥ 15 kV) can be used to reproducibly generate spherical alginate beads (200–400 μm) with narrow size distribution (± 5–7%) in a controlled manner under optimized process parameters. Flow rate of alginate solution ranged from 0.5 to 10 ml/h allowed producing alginate beads with a size of 320 and 350 μm respectively, suggesting that this approach can be scaled up. Moreover, we found that applied voltages (15–25 kV) did not alter the viability and proliferation of encapsulated mesenchymal stem cells post-encapsulation and cryopreservation as compared to air flow. We are the first who employed a comparative analysis of electro-spraying and air flow encapsulation to study the effect of high voltage on alginate encapsulated cells. This report provides background in application of high voltage to encapsulate living cells for further medical purposes. Long-term comparison and work on alginate–cell interaction within these structures will be forthcoming. - Highlights: • High voltage alginate encapsulation of mesenchymal stem cells (MSCs) was designed. • Reproducible and spherical alginate beads were generated via high voltage. • Air flow encapsulation was utilized as a comparative approach to high voltage. • High voltage did not alter the viability and proliferation of encapsulated MSCs. • High voltage encapsulation can be scaled up and applied in cell-based therapy.

  20. Enhanced Model of Nonlinear Spiral High Voltage Divider

    Directory of Open Access Journals (Sweden)

    V. Panko

    2015-04-01

    Full Text Available This paper deals with the enhanced accurate DC and RF model of nonlinear spiral polysilicon voltage divider. The high resistance polysilicon divider is a sensing part of the high voltage start-up MOSFET transistor that can operate up to 700 V. This paper presents the structure of a proposed model, implemented voltage, frequency and temperature dependency, and scalability. A special attention is paid to the ability of the created model to cover the mismatch and influence of a variation of process parameters on the device characteristics. Finally, the comparison of measured data vs. simulation is presented in order to confirm the model validity and a typical application is demonstrated.

  1. Performance of Doubly-Fed Wind Power Generators During Voltage Dips

    DEFF Research Database (Denmark)

    Aparicio, N.; Chen, Zhe; Beltran, H.

    The growing of wind generation in Spain has forced its Transmission System Operator (TSO) to release new requirements that establish the amount of reactive power that a wind turbine has to supply to the grid during a voltage dip. Wind turbines equipped with doubly-fed induction generators (DFIG......) can regulate easily the reactive power generated in steady state. However, difficulties appear when reactive power has to be generated during voltage dips. Simulations have been carried out in order to check whether DFIG wind turbines can fulfill the reactive power requirements. Protection system...... acting as STATCOM helps to improve the voltage profile sufficiently to permit rotor-side converter reconnection....

  2. An Integrated Chip High-Voltage Power Receiver for Wireless Biomedical Implants

    Directory of Open Access Journals (Sweden)

    Vijith Vijayakumaran Nair

    2015-06-01

    Full Text Available In near-field wireless-powered biomedical implants, the receiver voltage largely overrides the compliance of low-voltage power receiver systems. To limit the induced voltage, generally, low-voltage topologies utilize limiter circuits, voltage clippers or shunt regulators, which are power-inefficient methods. In order to overcome the voltage limitation and improve power efficiency, we propose an integrated chip high-voltage power receiver based on the step down approach. The topology accommodates voltages as high as 30 V and comprises a high-voltage semi-active rectifier, a voltage reference generator and a series regulator. Further, a battery management circuit that enables safe and reliable implant battery charging based on analog control is proposed and realized. The power receiver is fabricated in 0.35-μm high-voltage Bipolar-CMOS-DMOStechnology based on the LOCOS0.35-μm CMOS process. Measurement results indicate 83.5% power conversion efficiency for a rectifier at 2.1 mA load current. The low drop-out regulator based on the current buffer compensation and buffer impedance attenuation scheme operates with low quiescent current, reduces the power consumption and provides good stability. The topology also provides good power supply rejection, which is adequate for the design application. Measurement results indicate regulator output of 4 ± 0.03 V for input from 5 to 30 V and 10 ± 0.05 V output for input from 11 to 30 V with load current 0.01–100 mA. The charger circuit manages the charging of the Li-ion battery through all if the typical stages of the Li-ion battery charging profile.

  3. Flow-driven voltage generation in carbon nanotubes

    Indian Academy of Sciences (India)

    The flow of various liquids and gases over single-walled carbon nanotube bundles induces an electrical signal (voltage/current) in the sample along the ... to the nanotubes, the gas flow effect can be seen for a variety of solids ranging from single and multi-walled carbon nanotubes, graphite and doped semiconductors.

  4. Highly-Efficient and Modular Medium-Voltage Converters

    Science.gov (United States)

    2015-09-28

    of the modular multilevel converter based on si and sic switching devices for medium/high-voltage applications," IEEE Trans. Electron Devices, vol...4. TITLE AND SUBTITLE Highly-Efficient and Modula Medium-Voltage Converters 6. AUTHOR(S) Maryam Saeedifard 7. PERFORMING ORGANIZATIC i NAME(S...improving the converter’s efficiency and power density. 15. SUBJECT TERMS Modular Multilevel Converters , DC-DC Conversion, DC-AC Conversion 16

  5. Study of protection devices against the effects of electric discharges inside a very high voltage generator: the Vivitron accelerator; Etude de dispositifs de protection contre les effets des decharges electriques au sein d`un generateur de tres haute tension: l`accelerateur Vivitron

    Energy Technology Data Exchange (ETDEWEB)

    Nolot, E.

    1996-10-31

    The Vivitron tandem is a large electrostatic accelerator comprising a Van de Graaff generator designed to reach terminal voltages of around 30 MV. The machine is limited at rather lower nominal voltages (about 20 MV) due to the sensitivity of the insulating column structure to transient overvoltages. These are induced by electrical discharges in compressed SF{sub 6}. This thesis first aims at analysing the fundamental reasons of electrical discharges in order to limit the probability of their occurrence. Then we simulate the transient overvoltages induced and present some improvements which may lead to a stable behaviour of the Vivitron at nominal voltages higher than 20 MV. Initially we deduce discharge onset voltages and actual breakdown field limitations in the different gap geometries from analysis of possible breakdown mechanisms in compressed SF{sub 6}. In a second part, some electrical characteristics of the insulating column structure are measured at high voltage. Fast rising oscillating waves induced by sparking in the Vivitron, along with the associated energies,are determined in the third part. The last part deals with new surge protections of the insulating column structure. Spark gaps with precise onset voltage and optimized shielding electrodes are discussed. ZnO-based varistors designed for operation at very high fields have also been developed in order to reduce transient overvoltage values. (author). 122 refs.

  6. High Voltage Bi-directional Flyback Converter for Capacitive Actuator

    DEFF Research Database (Denmark)

    Thummala, Prasanth; Zhang, Zhe; Andersen, Michael A. E.

    2013-01-01

    This paper presents a high voltage DC-DC converter topology for bi-directional energy transfer between a low voltage DC source and a high voltage capacitive load. The topology is a bi-directional flyback converter with variable switching frequency control during the charge mode, and constant...... switching frequency control during the discharge mode. The converter is capable of charging the capacitive load from 24 V DC source to 2.5 kV, and discharges it to 0 V. The flyback converter has been analyzed in detail during both charge and discharge modes, by considering all the parasitic elements...... in the converter, including the most dominating parameters of the high voltage transformer viz., self-capacitance and leakage inductance. The specific capacitive load for this converter is a dielectric electro active polymer (DEAP) actuator, which can be used as an effective replacement for conventional actuators...

  7. High Input Voltage, Silicon Carbide Power Processing Unit Performance Demonstration

    Science.gov (United States)

    Bozak, Karin E.; Pinero, Luis R.; Scheidegger, Robert J.; Aulisio, Michael V.; Gonzalez, Marcelo C.; Birchenough, Arthur G.

    2015-01-01

    A silicon carbide brassboard power processing unit has been developed by the NASA Glenn Research Center in Cleveland, Ohio. The power processing unit operates from two sources: a nominal 300 Volt high voltage input bus and a nominal 28 Volt low voltage input bus. The design of the power processing unit includes four low voltage, low power auxiliary supplies, and two parallel 7.5 kilowatt (kW) discharge power supplies that are capable of providing up to 15 kilowatts of total power at 300 to 500 Volts (V) to the thruster. Additionally, the unit contains a housekeeping supply, high voltage input filter, low voltage input filter, and master control board, such that the complete brassboard unit is capable of operating a 12.5 kilowatt Hall effect thruster. The performance of the unit was characterized under both ambient and thermal vacuum test conditions, and the results demonstrate exceptional performance with full power efficiencies exceeding 97%. The unit was also tested with a 12.5kW Hall effect thruster to verify compatibility and output filter specifications. With space-qualified silicon carbide or similar high voltage, high efficiency power devices, this would provide a design solution to address the need for high power electric propulsion systems.

  8. High Input Voltage, Silicon Carbide Power Processing Unit Performance Demonstration

    Science.gov (United States)

    Bozak, Karin E.; Pinero, Luis R.; Scheidegger, Robert J.; Aulisio, Michael V.; Gonzalez, Marcelo C.; Birchenough, Arthur G.

    2015-01-01

    A silicon carbide brassboard power processing unit has been developed by the NASA Glenn Research Center in Cleveland, Ohio. The power processing unit operates from two sources - a nominal 300-Volt high voltage input bus and a nominal 28-Volt low voltage input bus. The design of the power processing unit includes four low voltage, low power supplies that provide power to the thruster auxiliary supplies, and two parallel 7.5 kilowatt power supplies that are capable of providing up to 15 kilowatts of total power at 300-Volts to 500-Volts to the thruster discharge supply. Additionally, the unit contains a housekeeping supply, high voltage input filter, low voltage input filter, and master control board, such that the complete brassboard unit is capable of operating a 12.5 kilowatt Hall Effect Thruster. The performance of unit was characterized under both ambient and thermal vacuum test conditions, and the results demonstrate the exceptional performance with full power efficiencies exceeding 97. With a space-qualified silicon carbide or similar high voltage, high efficiency power device, this design could evolve into a flight design for future missions that require high power electric propulsion systems.

  9. Variable speed wind turbine generator system with current controlled voltage source inverter

    Energy Technology Data Exchange (ETDEWEB)

    Muyeen, S.M., E-mail: muyeen0809@yahoo.co [Dept. of Electrical Engineering, Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Al-Durra, Ahmed [Dept. of Electrical Engineering, The Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Tamura, J. [Dept. of EEE, Kitami Institute of Technology, 165 Koen-cho, Kitami 090-8507 (Japan)

    2011-07-15

    highlights: {yields} Current controlled voltage source inverter scheme for wind power application. {yields} Low voltage ride through of wind farm. {yields} Variable speed wind turbine driven permanent magnet synchronous generator-operation and control. -- Abstract: The present popular trend of wind power generation is to use variable speed wind turbine (VSWT) driving a doubly fed induction generator (DFIG), wound field synchronous generator (WFSG) or permanent magnet synchronous generator (PMSG). Among them, stability analyses of DFIG type of VSWT have already been reported in many literatures. However, transient stability and low voltage ride through (LVRT) characteristics analyses for synchronous generator type of VSWT is not sufficient enough. This paper focuses on detailed LVRT characteristic analysis of variable speed wind turbine driving a PMSG (VSWT-PMSG) with current controlled voltage source inverter (CC-VSI). Modeling and suitable control strategies for overall system are developed to augment the low voltage ride through capability of variable speed wind generator, considering recent wind farm grid code. Both symmetrical and unsymmetrical faults are analyzed as network disturbances in this paper. The permanent fault due to unsuccessful reclosing of circuit breakers is taken into consideration, which is a salient feature of this study. Moreover, the dynamic characteristic is analyzed using real wind speed data measured in Hokkaido Island, Japan. The proposed control scheme is simulated by using the standard power system simulation package PSCAD/EMTDC and results are verified by comparing that of voltage controlled voltage source inverter scheme available in power system literature.

  10. Planar LTCC transformers for high voltage flyback converters: Part II.

    Energy Technology Data Exchange (ETDEWEB)

    Schofield, Daryl (NASCENTechnology, Inc., Watertown, SD); Schare, Joshua M., Ph.D.; Slama, George (NASCENTechnology, Inc., Watertown, SD); Abel, David (NASCENTechnology, Inc., Watertown, SD)

    2009-02-01

    This paper is a continuation of the work presented in SAND2007-2591 'Planar LTCC Transformers for High Voltage Flyback Converters'. The designs in that SAND report were all based on a ferrite tape/dielectric paste system originally developed by NASCENTechnoloy, Inc, who collaborated in the design and manufacturing of the planar LTCC flyback converters. The output/volume requirements were targeted to DoD application for hard target/mini fuzing at around 1500 V for reasonable primary peak currents. High voltages could be obtained but with considerable higher current. Work had begun on higher voltage systems and is where this report begins. Limits in material properties and processing capabilities show that the state-of-the-art has limited our practical output voltage from such a small part volume. In other words, the technology is currently limited within the allowable funding and interest.

  11. A High-Voltage Test Bed for the Evaluation of High-Voltage Dividers for Pulsed Applications

    CERN Document Server

    Bastos, M C; Hammarquist, M

    2011-01-01

    The design, evaluation, and commissioning of a high-voltage reference test bed for pulsed applications to be used in the precision testing of high-voltage dividers is described. The test bed is composed of a pulsed power supply, a reference divider based on compressed-gas capacitor technology, and an acquisition system that makes use of the fast measurement capabilities of the HP3458 digital voltmeter. The results of the evaluation of the reference system are presented.

  12. Reliability and Characterization of High Voltage Power Capacitors

    Science.gov (United States)

    2014-03-01

    permittivity EVCS electric vehicle charging system GPIB general-purpose interface bus GW giga-watt HVST high voltage stress test IV current voltage...traditional fossil fuel . The typical solar power system requires multiple subsystems as well as the physical infrastructure to support the solar panels. The...that will last, reducing the militaries overall dependence on traditional fossil fuel . B. CONVERTER OVERVIEW The typical solar power system

  13. Integrated Reconfigurable High-Voltage Transmitting Circuit for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Jørgensen, Ivan Harald Holger

    2014-01-01

    -out and measurements are performed on the integrated circuit. The transmitting circuit is reconfigurable externally making it able to drive a wide variety of CMUTs. The transmitting circuit can generate several pulse shapes, pulse voltages up to 100 V, maximum pulse range of 50 V and frequencies up to 5 MHz. The area...

  14. Understanding and Improving High Voltage Vacuum Insulators for Microsecond Pulses

    Energy Technology Data Exchange (ETDEWEB)

    Javedani, J B; Goerz, D A; Houck, T L; Lauer, E J; Speer, R D; Tully, L K; Vogtlin, G E; White, A D

    2007-03-05

    High voltage insulation is one of the main areas of pulsed power research and development, and dielectric breakdown is usually the limiting factor in attaining the highest possible performance in pulsed power devices. For many applications the delivery of pulsed power into a vacuum region is the most critical aspect of operation. The surface of an insulator exposed to vacuum can fail electrically at an applied field more than an order or magnitude below the bulk dielectric strength of the insulator. This mode of breakdown, called surface flashover, imposes serious limitations on the power flow into a vacuum region. This is especially troublesome for applications where high voltage conditioning of the insulator and electrodes is not practical and for applications where relatively long pulses, on the order of several microseconds, are required. The goal of this project is to establish a sound fundamental understanding of the mechanisms that lead to surface flashover, and then evaluate the most promising techniques to improve vacuum insulators and enable high voltage operation at stress levels near the intrinsic bulk breakdown limits of the material. The approach we proposed and followed was to develop this understanding through a combination of theoretical and computation methods coupled with experiments to validate and quantify expected behaviors. In this report we summarize our modeling and simulation efforts, theoretical studies, and experimental investigations. The computational work began by exploring the limits of commercially available codes and demonstrating methods to examine field enhancements and defect mechanisms at microscopic levels. Plasma simulations with particle codes used in conjunction with circuit models of the experimental apparatus enabled comparisons with experimental measurements. The large scale plasma (LSP) particle-in-cell (PIC) code was run on multiprocessor platforms and used to simulate expanding plasma conditions in vacuum gap regions

  15. Low voltage surface transverse wave oscillators for the next generation CMOS technology.

    Science.gov (United States)

    Avramov, Ivan D

    2005-08-01

    The design and performance of voltage controlled surface transverse wave oscillators (VCSTWO) in the lower gigahertz frequency range, operating on supply and tuning voltages in the 1.2 to 3.3 V range, and suitable for direct interfacing with the next generation CMOS circuits are presented. By applying the "boost" principle, as used in direct current (DC)-DC converters, to the design of the sustaining amplifier, the VCSTWO outputs are switched between 0 V and a positive peak value, exceeding the supply voltage Us, to provide safe CMOS-circuit switching while keeping the radio frequency (RF)/DC efficiency to a maximum for low DC power consumption. The investigated 1.0 and 2.5 GHz VCSTWO are varactor tuned feedback-loop oscillators stabilized with two-port surface transverse wave (STW) resonators. Each VCSTWO has a DC-coupled, high-impedance switched output to drive the CMOS circuit directly, and an additional sinusoidal 50 ohmz high-power reference output available for other low-noise system applications. Phase noise levels in the -103 to -115 dBc/Hz range at 1 kHz carrier offset are achieved with 1.0 GHz VCSTWO at a RF/DC efficiency in the 21 to 29% range. The 2.5 GHz prototypes demonstrate phase noise levels in the -97 to -102 dBc/Hz range at 1 kHz carrier offset, and efficiencies range between 8 and 15%.

  16. Two Players Make a Formidable Combination: In Situ Generated Poly(acrylic anhydride-2-methyl-acrylic acid-2-oxirane-ethyl ester-methyl methacrylate) Cross-Linking Gel Polymer Electrolyte toward 5 V High-Voltage Batteries.

    Science.gov (United States)

    Ma, Yue; Ma, Jun; Chai, Jingchao; Liu, Zhihong; Ding, Guoliang; Xu, Gaojie; Liu, Haisheng; Chen, Bingbing; Zhou, Xinhong; Cui, Guanglei; Chen, Liquan

    2017-11-29

    Electrochemical performance of high-voltage lithium batteries with high energy density is limited because of the electrolyte instability and the electrode/electrolyte interfacial reactivity. Hence, a cross-linking polymer network of poly(acrylic anhydride-2-methyl-acrylic acid-2-oxirane-ethyl ester-methyl methacrylate) (PAMM)-based electrolyte was introduced via in situ polymerization inspired by "shuangjian hebi", which is a statement in a traditional Chinese Kungfu story similar to the synergetic effect of 1 + 1 > 2. A poly(acrylic anhydride) and poly(methyl methacrylate)-based system is very promising as electrolyte materials for lithium-ion batteries, in which the anhydride and acrylate groups can provide high voltage resistance and fast ionic conductivity, respectively. As a result, the cross-linking PAMM-based electrolyte possesses a significant comprehensive enhancement, including electrochemical stability window exceeding 5 V vs Li+/Li, an ionic conductivity of 6.79 × 10-4 S cm-1 at room temperature, high mechanical strength (27.5 MPa), good flame resistance, and excellent interface compatibility with Li metal. It is also demonstrated that this gel polymer electrolyte suppresses the negative effect resulting from dissolution of Mn2+ ions at 25 and 55 °C. Thus, the LiNi0.5Mn1.5O4/Li and LiNi0.5Mn1.5O4/Li4Ti5O12 cells using the optimized in situ polymerized cross-linking PAMM-based gel polymer electrolyte deliver stable charging/discharging profiles and excellent rate performance at room temperature and even at 55 °C. These findings suggest that the cross-linking PAMM is an intriguing candidate for 5 V class high-voltage gel polymer electrolyte toward high-energy lithium-on batteries.

  17. Wind farms generation limits and its impact in real-time voltage stability assessment

    DEFF Research Database (Denmark)

    Perez, Angel; Jóhannsson, Hjörtur; Østergaard, Jacob

    2015-01-01

    indicates the distance to the limit activation and theeffect of each load in such a limit. The wind farm control schemesincludes voltage control and it is represented as a constantcurrent at its limit. A criteria to select the critical bus bar, basedon the generator transformation coefficients, is presented....... Thismethodology is tested in a platform that produces synthesizedPMU measurements from time-domain simulations and criticalboundary for the wind-farm limits are shown. The methodology isalso tested for synchronous machines and its parallel structure isexploited when implemented in a High Performance...

  18. Controlled Compact High Voltage Power Lines

    OpenAIRE

    Postolati V.; Bycova Е.; Suslov V.; Timashova L.; Shakarian Yu.; Kareva S.

    2016-01-01

    Nowadays modern overhead transmission lines (OHL) constructions having several significant differences from conventional ones are being used in power grids more and more widely. Implementation of compact overhead lines equipped with FACTS devices, including phase angle regulator settings (compact controlled OHL), appears to be one of the most effective ways of power grid development. Compact controlled AC HV OHL represent a new generation of power transmission lines embodying recent advanced ...

  19. Architecture for a High-to-Medium-Voltage Power Converter

    Science.gov (United States)

    Vorpenian, Vatche

    2008-01-01

    A power converter now undergoing development is required to operate at a DC input potential ranging between 5.5 and 10 kV and a DC output potential of 400 V at a current up to 25 A. This power converter is also required to be sufficiently compact and reliable to fit and operate within the confines of a high-pressure case to be lowered to several miles (approx.5 km) below the surface of the ocean. The architecture chosen to satisfy these requirements calls for a series/ parallel arrangement of 48 high-frequency, pulse-width-modulation (PWM), transformer-isolation DC-to-DC power converter blocks. The input sides of the converter blocks would be connected in series so that the input potential would be divided among them, each of them being exposed to an input potential of no more than 10 kV/48 . 210 V. The series connection of inputs would also enforce a requirement that all the converter blocks operate at the same input current. The outputs of the converter blocks would be connected in a matrix comprising 6 parallel legs, each leg being a cascade of eight outputs wired in series (see figure). All the converter blocks would be identical within the tolerances of the values of their components. A single voltage feedback loop would regulate the output potential. All the converter blocks would be driven by the same PWM waveform generated by this feedback loop. The power transformer of each converter block would have a unity turns ratio and would be capable of withstanding as much as 10 kVDC between its primary and secondary windings. (Although, in general, the turns ratio could be different from unity, the simplest construction for minimizing leakage and maximizing breakdown voltage is attained at a turns ratio of unity.)

  20. Increase the threshold voltage of high voltage GaN transistors by low temperature atomic hydrogen treatment

    Energy Technology Data Exchange (ETDEWEB)

    Erofeev, E. V., E-mail: erofeev@micran.ru [Tomsk State University of Control Systems and Radioelectronics, Research Institute of Electrical-Communication Systems (Russian Federation); Fedin, I. V.; Kutkov, I. V. [Research and Production Company “Micran” (Russian Federation); Yuryev, Yu. N. [National Research Tomsk Polytechnic University, Institute of Physics and Technology (Russian Federation)

    2017-02-15

    High-electron-mobility transistors (HEMTs) based on AlGaN/GaN epitaxial heterostructures are a promising element base for the fabrication of high voltage electronic devices of the next generation. This is caused by both the high mobility of charge carriers in the transistor channel and the high electric strength of the material, which makes it possible to attain high breakdown voltages. For use in high-power switches, normally off-mode GaN transistors operating under enhancement conditions are required. To fabricate normally off GaN transistors, one most frequently uses a subgate region based on magnesium-doped p-GaN. However, optimization of the p-GaN epitaxial-layer thickness and the doping level makes it possible to attain a threshold voltage of GaN transistors close to V{sub th} = +2 V. In this study, it is shown that the use of low temperature treatment in an atomic hydrogen flow for the p-GaN-based subgate region before the deposition of gate-metallization layers makes it possible to increase the transistor threshold voltage to V{sub th} = +3.5 V. The effects under observation can be caused by the formation of a dipole layer on the p-GaN surface induced by the effect of atomic hydrogen. The heat treatment of hydrogen-treated GaN transistors in a nitrogen environment at a temperature of T = 250°C for 12 h reveals no degradation of the transistor’s electrical parameters, which can be caused by the formation of a thermally stable dipole layer at the metal/p-GaN interface as a result of hydrogenation.

  1. High impulse voltage and current measurement techniques fundamentals, measuring instruments, measuring methods

    CERN Document Server

    Schon, Klaus

    2013-01-01

    Equipment to be installed in electric power-transmission and distribution systems must pass acceptance tests with standardized high-voltage or high-current test impulses which simulate the stress on the insulation caused by external lightning discharges and switching operations in the grid. High impulse voltages and currents are also used in many other fields of science and engineering for various applications. Therefore, precise impulse-measurement techniques are necessary, either to prevent an over- or understressing of the insulation or to guarantee the effectiveness and quality of the application. The book deals with: principal generator circuits for generating high-voltage and high-current impulses measuring systems and their calibration according to IEC 60060 and IEC 62475 methods of estimating uncertainties of measurement mathematical and experimental basis for characterizing the transfer behavior of spatially extended systems used for measuring fast transients. This book is intended for engineers and ...

  2. A flexible low-voltage ride-through operation for the distributed generation converters

    DEFF Research Database (Denmark)

    Chen, Hsin-Chih; Lee, Chia-Tse; Cheng, Po-Tai

    2013-01-01

    With more and more distributed energy resources (DERs) are installed in the utility grid, the utility requires the DER generation system to remain grid-connected and injects reactive and active power to support grid voltage during voltage sags. In this paper, a positive- and negative......-sequence current injection method is proposed to meet the low-voltage ride through (LVRT) requirement. The proposed method predefined a current constraint to avoid the overcurrent during the LVRT operation and adjust the positive-sequence reactive current to reduce the DC-bus voltage ripple. Comparisons...

  3. Unbalanced voltage control of virtual synchronous generator in isolated micro-grid

    Science.gov (United States)

    Cao, Y. Z.; Wang, H. N.; Chen, B.

    2017-06-01

    Virtual synchronous generator (VSG) control is recommended to stabilize the voltage and frequency in isolated micro-grid. However, common VSG control is challenged by widely used unbalance loads, and the linked unbalance voltage problem worsens the power quality of the micro-grid. In this paper, the mathematical model of VSG was presented. Based on the analysis of positive- and negative-sequence equivalent circuit of VSG, an approach was proposed to eliminate the negative-sequence voltage of VSG with unbalance loads. Delay cancellation method and PI controller were utilized to identify and suppress the negative-sequence voltages. Simulation results verify the feasibility of proposed control strategy.

  4. Voltage and frequency control of wind-powered islanded microgrids based on induction generator and STATCOM

    DEFF Research Database (Denmark)

    Bouzid, Allal; Sicard, Pierre; Guerrero, Josep M.

    2015-01-01

    This paper presents a comprehensive modeling of a three-phase cage induction machine used as a self-excited squirrel-cage induction generator (SEIG), and discusses the regulation of the voltage and frequency of a self-excited SEIG based on the action of the static synchronous Compensator (STATCOM......). The STATCOM with the proposed controller consists of a three-phase voltage-sourced inverter and a DC voltage. The compensator can provide the active and reactive powers and regulate AC system bus voltage and the frequency, but also may enhance the load stability. Moreover, a feed forward control method...

  5. Environmental and biotechnological applications of high-voltage pulsed discharges in water

    Science.gov (United States)

    Sato, Masayuki

    2008-05-01

    A high-voltage pulse has wide application in fields such as chemistry, physics and biology and their combinations. The high-voltage pulse forms two kinds of physical processes in water, namely (a) a pulsed electric field (PEF) in the parallel electrode configuration and (b) plasma generation by a pulsed discharge in the water phase with a concentrated electric field. The PEF can be used for inactivation of bacteria in liquid foods as a non-thermal process, and the underwater plasma is applicable not only for the decomposition of organic materials in water but also for biological treatment of wastewater. These discharge states are controlled mainly by the applied pulse voltage and the electrode shape. Some examples of environmental and biotechnological applications of a high-voltage pulse are reviewed.

  6. Design of High-Voltage Switch-Mode Power Amplifier Based on Digital-Controlled Hybrid Multilevel Converter

    National Research Council Canada - National Science Library

    Hou, Yanbin; Sun, Wanrong; Ren, Aifeng; Liu, Shuming

    2016-01-01

    ...) and hybrid multilevel converter. Under the control of input signal, cascaded power converters with separate DC sources operate in PSM switch mode to directly generate high-voltage and high-power output...

  7. Experimental investigation of SDBD plasma actuator driven by AC high voltage with a superimposed positive pulse bias voltage

    Science.gov (United States)

    Qi, Xiao-Hua; Yan, Hui-Jie; Yang, Liang; Hua, Yue; Ren, Chun-Sheng

    2017-08-01

    In this work, a driven voltage consisting of AC high voltage with a superimposed positive pulse bias voltage ("AC+ Positive pulse bias" voltage) is adopted to study the performance of a surface dielectric barrier discharge plasma actuator under atmospheric conditions. To compare the performance of the actuator driven by single-AC voltage and "AC+ Positive pulse bias" voltage, the actuator-induced thrust force and power consumption are measured as a function of the applied AC voltage, and the measured results indicate that the thrust force can be promoted significantly after superimposing the positive pulse bias voltage. The physical mechanism behind the thrust force changes is analyzed by measuring the optical properties, electrical characteristics, and surface potential distribution. Experimental results indicate that the glow-like discharge in the AC voltage half-cycle, next to the cycle where a bias voltage pulse has been applied, is enhanced after applying the positive pulse bias voltage, and this perhaps is the main reason for the thrust force increase. Moreover, surface potential measurement results reveal that the spatial electric field formed by the surface charge accumulation after positive pulse discharge can significantly affect the applied external electric field, and this perhaps can be responsible for the experimental phenomenon that the decrease of thrust force is delayed by pulse bias voltage action after the filament discharge occurs in the glow-like discharge region. The schlieren images further verify that the actuator-induced airflow velocity increases with the positive pulse voltage.

  8. Rectenna for high-voltage applications

    Science.gov (United States)

    Epp, Larry W. (Inventor); Khan, Abdur R. (Inventor)

    2002-01-01

    An energy transfer system is disclosed. The system includes patch elements, shielding layers, and energy rectifying circuits. The patch elements receive and couple radio frequency energy. The shielding layer includes at least one opening that allows radio frequency energy to pass through. The openings are formed and positioned to receive the radio frequency energy and to minimize any re-radiating back toward the source of energy. The energy rectifying circuit includes a circuit for rectifying the radio frequency energy into dc energy. A plurality of energy rectifying circuits is arranged in an array to provide a sum of dc energy generated by the energy rectifying circuit.

  9. Voltage generation of piezoelectric cantilevers by laser heating.

    Science.gov (United States)

    Hsieh, Chun-Yi; Liu, Wei-Hung; Chen, Yang-Fang; Shih, Wan Y; Gao, Xiaotong; Shih, Wei-Heng

    2012-11-15

    Converting ambient thermal energy into electricity is of great interest in harvesting energy from the environment. Piezoelectric cantilevers have previously been shown to be an effective biosensor and a tool for elasticity mapping. Here we show that a single piezoelectric (lead-zirconate titanate (PZT)) layer cantilever can be used to convert heat to electricity through pyroelectric effect. Furthermore, piezoelectric-metal (PZT-Ti) bi-layer cantilever showed an enhanced induced voltage over the single PZT layer alone due to the additional piezoelectric effect. This type of device can be a way for converting heat energy into electricity.

  10. Statistical characteristics of transient enclosure voltage in ultra-high-voltage gas-insulated switchgear

    Science.gov (United States)

    Cai, Yuanji; Guan, Yonggang; Liu, Weidong

    2017-06-01

    Transient enclosure voltage (TEV), which is a phenomenon induced by the inner dielectric breakdown of SF6 during disconnector operations in a gas-insulated switchgear (GIS), may cause issues relating to shock hazard and electromagnetic interference to secondary equipment. This is a critical factor regarding the electromagnetic compatibility of ultra-high-voltage (UHV) substations. In this paper, the statistical characteristics of TEV at UHV level are collected from field experiments, and are analyzed and compared to those from a repeated strike process. The TEV waveforms during disconnector operations are recorded by a self-developed measurement system first. Then, statistical characteristics, such as the pulse number, duration of pulses, frequency components, magnitude and single pulse duration, are extracted. The transmission line theory is introduced to analyze the TEV and is validated by the experimental results. Finally, the relationship between the TEV and the repeated strike process is analyzed. This proves that the pulse voltage of the TEV is proportional to the corresponding breakdown voltage. The results contribute to the definition of the standard testing waveform of the TEV, and can aid the protection of electronic devices in substations by minimizing the threat of this phenomenon.

  11. Temperature Stabilized Characterization of High Voltage Power Supplies

    CERN Document Server

    Krarup, Ole

    2017-01-01

    High precision measurements of the masses of nuclear ions in the ISOLTRAP experiment relies on an MR-ToF. A major source of noise and drift is the instability of the high voltage power supplies employed. Electrical noise and temperature changes can broaden peaks in time-of-flight spectra and shift the position of peaks between runs. In this report we investigate how the noise and drift of high-voltage power supplies can be characterized. Results indicate that analog power supplies generally have better relative stability than digitally controlled ones, and that the high temperature coefficients of all power supplies merit efforts to stabilize them.

  12. High voltage switch triggered by a laser-photocathode subsystem

    Science.gov (United States)

    Chen, Ping; Lundquist, Martin L.; Yu, David U. L.

    2013-01-08

    A spark gap switch for controlling the output of a high voltage pulse from a high voltage source, for example, a capacitor bank or a pulse forming network, to an external load such as a high gradient electron gun, laser, pulsed power accelerator or wide band radar. The combination of a UV laser and a high vacuum quartz cell, in which a photocathode and an anode are installed, is utilized as triggering devices to switch the spark gap from a non-conducting state to a conducting state with low delay and low jitter.

  13. Multi-objective optimization of distributed generation with voltage ...

    African Journals Online (AJOL)

    DR OKE

    The limitation of traditional power generation, increasing power demand and benefits of distributed generation (DG) have been .... used in wind farms, mainly come under this category. ..... research interests are distributed generation planning, state estimation, short term forecasting, and AI application in power systems.

  14. Controlled Compact High Voltage Power Lines

    Directory of Open Access Journals (Sweden)

    Postolati V.

    2016-04-01

    Full Text Available Nowadays modern overhead transmission lines (OHL constructions having several significant differences from conventional ones are being used in power grids more and more widely. Implementation of compact overhead lines equipped with FACTS devices, including phase angle regulator settings (compact controlled OHL, appears to be one of the most effective ways of power grid development. Compact controlled AC HV OHL represent a new generation of power transmission lines embodying recent advanced achievements in design solutions, including towers and insulation, together with interconnection schemes and control systems. Results of comprehensive research and development in relation to 110–500kV compact controlled power transmission lines together with theoretical basis, substantiation, and methodological approaches to their practical application are presented in the present paper.

  15. High-Voltage Converter for the Traction Application

    Directory of Open Access Journals (Sweden)

    Sergey Volskiy

    2016-01-01

    Full Text Available High-voltage converter employing IGCT switches (VDC=2800 V for traction application is presented. Such a power traction drive operates with an unstable input voltage over 2000⋯4000 V DC and with an output power up to 1200 kW. The original power circuit of the high-voltage converter is demonstrated. Development of the attractive approach to designing the low-loss snubber circuits of the high-frequency IGCT switches is proposed. It is established on the complex multilevel analysis of the transient phenomena and power losses. The essential characteristics of the critical parameters under transient modes and the relation between the snubber circuit parameters and the losses are discussed. Experimental results for the prototype demonstrate the properties of new power circuit. The test results confirm the proposed high-voltage converter performance capability as well as verifying the suitability of the conception for its use in the Russian suburban train power system and other high-voltage applications.

  16. E-beam high voltage switching power supply

    Science.gov (United States)

    Shimer, Daniel W.; Lange, Arnold C.

    1997-01-01

    A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

  17. Gaseous insulators for high voltage electrical equipment

    Science.gov (United States)

    Christophorou, Loucas G.; James, David R.; Pace, Marshall O.; Pai, Robert Y.

    1979-01-01

    Gaseous insulators comprise compounds having high attachment cross sections for electrons having energies in the 0-1.3 electron volt range. Multi-component gaseous insulators comprise compounds and mixtures having overall high electron attachment cross sections in the 0-1.3 electron volt range and moderating gases having high cross sections for inelastic interactions with electrons of energies 1-4 electron volts. Suitable electron attachment components include hexafluorobutyne, perfluorobutene-2, perfluorocyclobutane, perfluorodimethylcyclobutane, perfluorocyclohexene, perfluoromethylcyclohexane, hexafluorobutadiene, perfluoroheptene-1 and hexafluoroazomethane. Suitable moderating gases include N.sub.2, CO, CO.sub.2 and H.sub.2. The gaseous insulating mixture can also contain SF.sub.6, perfluoropropane and perfluorobenzene.

  18. Modeling of long High Voltage AC Underground

    DEFF Research Database (Denmark)

    Gudmundsdottir, Unnur Stella; Bak, Claus Leth; Wiechowski, W. T.

    2010-01-01

    cable models, perform highly accurate field measurements for validating the model and identifying possible disadvantages of the cable model. Furthermore the project suggests and implements improvements and validates them against several field measurements. It is shown in this paper how a new method...

  19. Coordinated Low Voltage Ride through strategies for Permanent Magnet Direct Drive Synchronous Generators

    Directory of Open Access Journals (Sweden)

    Zhang Ge

    2016-01-01

    Full Text Available By analyzing the mechanism of the low voltage ride through on the permanent magnet direct drive synchronous wind power generating units, this paper proposes a coordinated control strategy for permanent magnet synchronous generator. In order to avoid over speed operation of the generation units, over voltage on DC capacitor and over current on convert, the improved pitch angle control and inverter control are used. When the grid voltage drops, the captured wind power is cut down by the variable pitch system, which limits the speed of the generator, the generator side converter keeps the DC capacitor voltage stabile; and the grid side converter provides reactive power to the grid to help the grid voltage recover. The control strategy does not require any additional hardware equipment, with existing control means, the unit will be able to realize low voltage ride through. Finally, based on Matlab/Simulink to build permanent magnet direct drive wind power generation system, the simulation results verify the correctness and effectiveness of the control strategy.

  20. A strategy for protection of high voltage systems using resistive superconducting fault current limiters

    Science.gov (United States)

    Schettino, H. J.; Andrade, R. de, Jr.; Polasek, A.; Kottonau, D.; de Sousa, W. T. B.

    2018-01-01

    This work describes an use of a resistive superconducting fault current limiter (R-SFCL) device based on second generation high temperature superconductors tapes (2G tapes), using a thermal-electrical analogy method to represent heat exchanges. The considered SFCL is supposed to be inserted into the coupling point of a new generation unit to a 12 bar CIGRE benchmark transmission system. The strategy is the investigation of the limitation performance in the high voltage grid by connecting the SFCL at medium voltage grid. We evaluated the performance of the SFCL through the analysis of two cases of faults in different points of the system. Results show that a correct design of the SFCL may effectively limit the contribution of fault currents in the high voltage side. Additionally, it was possible to investigate the behavior of the device internal variables such as the temperature of the superconducting layers for the different cases studied.

  1. Performance analysis of voltage regulation in diesel-wind generation

    African Journals Online (AJOL)

    user

    2006-05-04

    May 4, 2006 ... Abstract. In presented paper performance analysis of the hybrid diesel-wind energy conversion system has presented. Electrical energy is generated by the two sources one source is the diesel engine generator and the other source is the wind energy conversion system the supply is provided to the ...

  2. High-Voltage Multiplexing for ATLAS ITk

    CERN Document Server

    Hommels, Bart; The ATLAS collaboration

    2017-01-01

    The High Luminosity upgrade to the Large Hadron Collider (HL-LHC) requires a replacement of the present ATLAS inner tracker with an all-silicon inner tracker (ITk). The outer radii of the ITk will consist of groups of silicon strip sensors mounted on common support structures. Lack of space for additional cabling will require groups of sensors to share a common HV bus (-500 V). This creates a need to remotely disable a failing sensor from the common HV bus to permit continued operation of the other sensors. We have developed circuitry consisting of a Gallium Nitride Field-Effect transistor (GaNFET) and a HV Multiplier circuit to disable a failed sensor. The devices have been shown to survive radiation doses as high as 1 x 1016 neutrons/cm2 and ionizing doses over 200 Mrad. We will present the HV Mux circuitry and show irradiation results on individual components with an emphasis on the GaNFET results with neutrons, protons, pions, and gammas. We will present a dual-stage variation of the HV Mux that will perm...

  3. High voltage pulsed cable design: a practical example

    Energy Technology Data Exchange (ETDEWEB)

    Kewish, R.W. Jr.; Boicourt, G.P.

    1979-01-01

    The design of optimum high voltage pulse cable is difficult because very little emperical data are available on performance in pulsed applications. This paper follows the design and testing of one high voltage pulse cable, 40/100 trigger cable. The design was based on an unproven theory and the impressive outcome lends support to the theory. The theory is outlined and it is shown that there exists an inductance which gives a cable of minimum size for a given maximum stress. Test results on cable manufactured according to the design are presented and compared with the test results on the cable that 40/100 replaces.

  4. Digitally gain controlled linear high voltage amplifier for laboratory applications

    Science.gov (United States)

    Koçum, C.

    2011-08-01

    The design of a digitally gain controlled high-voltage non-inverting bipolar linear amplifier is presented. This cost efficient and relatively simple circuit has stable operation range from dc to 90 kHz under the load of 10 kΩ and 39 pF. The amplifier can swing up to 360 Vpp under these conditions and it has 2.5 μs rise time. The gain can be changed by the aid of JFETs. The amplifiers have been realized using a combination of operational amplifiers and high-voltage discrete bipolar junction transistors. The circuit details and performance characteristics are discussed.

  5. The research of high voltage switchgear detecting unit

    Science.gov (United States)

    Ji, Tong; Xie, Wei; Wang, Xiaoqing; Zhang, Jinbo

    2017-07-01

    In order to understand the status of the high voltage switch in the whole life circle, you must monitor the mechanical and electrical parameters that affect device health. So this paper gives a new high voltage switchgear detecting unit based on ARM technology. It can measure closing-opening mechanical wave, storage motor current wave and contactor temperature to judge the device’s health status. When something goes wrong, it can be on alert and give some advice. The practice showed that it can meet the requirements of circuit breaker mechanical properties temperature online detection.

  6. Rotor Voltage Dynamics in the Doubly Fed Induction Generator During Grid Faults

    DEFF Research Database (Denmark)

    Lima, Francisco K. A.; Luna, Alvaro; Rodriguez, Pedro

    2010-01-01

    the system to control the initial overcurrents that appear in the generator during voltage sags, which can damage the RSC, without tripping it. As a difference with classical solutions, based on the installation of crowbar circuits, this operation mode permits to keep the inverter connected to the generator......This paper presents a new control strategy for the rotor-side converter (RSC) of wind turbines (WTs) based on doubly fed induction generators (DFIG) that intends to improve its low-voltage ride through capability. The main objective of this work is to design an algorithm that would enable......, something that would permit the injection of power to the grid during the fault, as the new grid codes demand. A theoretical study of the dynamical behavior of the rotor voltage is also developed, in order to show that the voltage at the rotor terminals required for the control strategy implementation...

  7. High reliability low jitter pulse generator

    Science.gov (United States)

    Savage, Mark E.; Stoltzfus, Brian S.

    2013-01-01

    A method and concomitant apparatus for generating pulses comprising providing a laser light source, disposing a voltage electrode between ground electrodes, generating laser sparks using the laser light source via laser spark gaps between the voltage electrode and the ground electrodes, and outputting pulses via one or more insulated ground connectors connected to the voltage electrode.

  8. High-voltage, high-current, solid-state closing switch

    Energy Technology Data Exchange (ETDEWEB)

    Focia, Ronald Jeffrey

    2017-08-22

    A high-voltage, high-current, solid-state closing switch uses a field-effect transistor (e.g., a MOSFET) to trigger a high-voltage stack of thyristors. The switch can have a high hold-off voltage, high current carrying capacity, and high time-rate-of-change of current, di/dt. The fast closing switch can be used in pulsed power applications.

  9. Digitally Programmable High-Q Voltage Mode Universal Filter

    Directory of Open Access Journals (Sweden)

    D. Singh

    2013-12-01

    Full Text Available A new low-voltage low-power CMOS current feedback amplifier (CFA is presented in this paper. This is used to realize a novel digitally programmable CFA (DPCFA using transistor arrays and MOS switches. The proposed realizations nearly allow rail-to-rail swing capability at all the ports. Class-AB output stage ensures low power dissipation and high current drive capability. The proposed CFA/ DPCFA operates at supply voltage of ±0.75 V and exhibits bandwidth better than 95 MHz. An application of the DPCFA to realize a novel voltage mode high-Q digitally programmable universal filter (UF is given. Performances of all the proposed circuits are verified by PSPICE simulation using TSMC 0.25μm technology parameters.

  10. High-voltage discharge in supersonic jet of plumbum vapor

    Science.gov (United States)

    Amirov, R. Kh; Antonov, N. N.; Liziakin, G. D.; Polistchook, V. P.; Samoylov, I. S.; Usmanov, R. A.; Yartsev, I. M.

    2015-11-01

    During study of vacuum discharge in plumbum evaporating from molybdenum crucible in identical geometry of discharge gap and the same crucible temperature existence of two different discharge forms were observed. These two forms are vacuum arc with current above 10 A and voltage about 15 V and high-voltage discharge with current about 10 mA and voltage of 340 V. Plumbum was placed in heat-isolated crucible (cathode). Electron-beam heater was situated under the crucible. At the temperature of 1.25 kK that corresponds to plumbum saturated vapor pressure about 0.1 kPa voltage from power source (380 V, 200 A) was applied to anode and high-voltage discharge initiated with characteristics mentioned above. After a few seconds this discharge could turn into arc or could exist hundreds of seconds until total plumbum evaporation. Glow of discharge could take the form of a cone, harness or plasma bunch that hanged at the appreciable distance from the electrodes. The estimations of plasma parameters are presented.

  11. Small Distributed Renewable Energy Generation for Low Voltage Distribution Networks

    OpenAIRE

    Chindris M.; Cziker A.; Miron Anca

    2016-01-01

    Driven by the existing energy policies, the use of renewable energy has increased considerably all over the world in order to respond to the increasing energy consumption and to reduce the environmental impact of the electricity generation. Although most policy makers and companies are focusing on large applications, the use of cheap small generation units, based on local renewable resources, has become increasingly attractive for the general public, small farms and remote communities. The pa...

  12. High Output Piezo/Triboelectric Hybrid Generator

    Science.gov (United States)

    Jung, Woo-Suk; Kang, Min-Gyu; Moon, Hi Gyu; Baek, Seung-Hyub; Yoon, Seok-Jin; Wang, Zhong-Lin; Kim, Sang-Woo; Kang, Chong-Yun

    2015-03-01

    Recently, piezoelectric and triboelectric energy harvesting devices have been developed to convert mechanical energy into electrical energy. Especially, it is well known that triboelectric nanogenerators have a simple structure and a high output voltage. However, whereas nanostructures improve the output of triboelectric generators, its fabrication process is still complicated and unfavorable in term of the large scale and long-time durability of the device. Here, we demonstrate a hybrid generator which does not use nanostructure but generates much higher output power by a small mechanical force and integrates piezoelectric generator into triboelectric generator, derived from the simultaneous use of piezoelectric and triboelectric mechanisms in one press-and-release cycle. This hybrid generator combines high piezoelectric output current and triboelectric output voltage, which produces peak output voltage of ~370 V, current density of ~12 μA.cm-2, and average power density of ~4.44 mW.cm-2. The output power successfully lit up 600 LED bulbs by the application of a 0.2 N mechanical force and it charged a 10 μF capacitor to 10 V in 25 s. Beyond energy harvesting, this work will provide new opportunities for developing a small, built-in power source in self-powered electronics such as mobile electronics.

  13. Switched Reluctance Generator Output Voltage Ripple Reduction Based on Fuzzy Sliding Mode

    Directory of Open Access Journals (Sweden)

    Xia Fei

    2015-01-01

    Full Text Available Aiming at the problem of Switched Reluctance Generator output voltage ripple, this paper designs a fuzzy sliding mode controller based on the analysis of various factors affecting the output voltage ripple. The traditional sliding mode controller has quick convergence, but it has chattering problem. This paper introduces the fuzzy control to select the appropriate sliding mode gain. It can combine with traditional angle control to adjust the output voltage by adjusting the conduction angle. It is more effective in shortening the adjustment time and reducing the overshoot and steady-state of error compared with the classical PID control. Meanwhile, it also solves the chattering problem of traditional sliding mode control. Finally, it makes use of nonlinear model structure to validate that it is effective in restraining voltage ripple and improving the dynamic performance of the system and the voltage quality.

  14. Study of a High Voltage Ion Engine Power Supply

    Science.gov (United States)

    Stuart, Thomas A.; King, Roger J.; Mayer, Eric

    1996-01-01

    A complete laboratory breadboard version of a ion engine power converter was built and tested. This prototype operated on a line voltage of 80-120 Vdc, and provided output ratings of 1100 V at 1.8 kW, and 250 V at 20 mA. The high-voltage (HV) output voltage rating was revised from the original value of 1350 V at the beginning of the project. The LV output was designed to hold up during a 1-A surge current lasting up to 1 second. The prototype power converter included a internal housekeeping power supply which also operated from the line input. The power consumed in housekeeping was included in the overall energy budget presented for the ion engine converter. HV and LV output voltage setpoints were commanded through potentiometers. The HV converter itself reached its highest power efficiency of slightly over 93% at low line and maximum output. This would dip below 90% at high line. The no-load (rated output voltages, zero load current) power consumption of the entire system was less than 13 W. A careful loss breakdown shows that converter losses are predominately Metal-Oxide-Semiconductor Field Effect Transistor (MOSFET) conduction losses and HV rectifier snubbing losses, with the rectifier snubbing losses becoming predominant at high line. This suggests that further improvements in power efficiency could best be obtained by either developing a rectifier that was adequately protected against voltage overshoot with less snubbing, or by developing a pre-regulator to reduced the range of line voltage on the converter. The transient testing showed the converter to be fully protected against load faults, including a direct short-circuit from the HV output to the LV output terminals. Two currents sensors were used: one to directly detect any core ratcheting on the output transformer and re-initiate a soft start, and the other to directly detect a load fault and quickly shut down the converter for load protection. The finished converter has been extensively fault tested

  15. Digital measurement system for the LHC klystron high voltage modulator.

    CERN Document Server

    Mikkelsen, Anders

    Accelerating voltage in the Large Hadron Collider (LHC) is created by a means of 16 superconducting standing wave RF cavities, each fed by a 400MHz/300kW continuous wave klystron amplifier. Part of the upgrade program for the LHC long shutdown one is to replace the obsolete analogue current and voltage measurement circuitry located in the high voltage bunkers by a new, digital system, using ADCs and optical fibres. A digital measurement card is implemented and integrated into the current HV modulator oil tank (floating at -58kV) and interfaced to the existing digital VME boards collecting the data for several klystrons at the ground potential. Measured signals are stored for the logging, diagnostics and post-mortem analysis purposes.

  16. Proximity effects of high voltage electric power transmission lines on ...

    African Journals Online (AJOL)

    Yomi

    Zeki Demir. Department of Landscape Architecture, Faculty of Forestry, Düzce University. Konuralp, 81620 Düzce, Turkey. E-mail: zekidemir@duzce.edu.tr. Tel: +90-380-5421136. Fax: +90-380-5421136. Accepted 18 August, 2010. The proximity effects of high voltage electric power transmission lines on Leyland Cypress.

  17. A Review of High Voltage Drive Amplifiers for Capacitive Actuators

    DEFF Research Database (Denmark)

    Huang, Lina; Zhang, Zhe; Andersen, Michael A. E.

    2012-01-01

    This paper gives an overview of the high voltage amplifiers, which are used to drive capacitive actuators. The amplifiers for both piezoelectric and DEAP (dielectric electroactive polymer) actuator are discussed. The suitable topologies for driving capacitive actuators are illustrated in detail...

  18. High Voltage Electrical Injuries In The University Of Calabar ...

    African Journals Online (AJOL)

    Background: Burn injuries are a common presentation in Nigerian hospitals and result from a variety of causes. Recently, many have resulted from Petroleum related fire incidents. High voltage electrical injuries are relatively rare; lightning strikes even rarer. In traditional societies where Traditional medicine practitioners are ...

  19. Proximity effects of high voltage electric power transmission lines on ...

    African Journals Online (AJOL)

    The proximity effects of high voltage electric power transmission lines on Leyland Cypress (xCupressocyparis leylandii (Dallim. and A.B. Jacks.) Dallim) and Japanese Privet (Ligustrum japonicum Thunb.) growth were examined in a private nursery located in Sakarya, Turkey. Five transect were randomly chosen in both ...

  20. Pulsed high voltage discharge induce hematologic changes | El ...

    African Journals Online (AJOL)

    The aim of this work to examine the effect of the gas-liquid hybrid discharge treatment system on some hematological parameters. The gas-liquid hybrid discharge (HD) reactor consists of high voltage point discharge electrode above blood surface and cylinderical ground copper electrode containing the blood (in the same ...

  1. Flow-driven voltage generation in carbon nanotubes

    Indian Academy of Sciences (India)

    nanotube plays a key role while electrical signal generation due to gas flow is due to an interplay of Bernoulli's principle ... 2.1 Experimental details, results and some applications of the flow sensor. The SWNT bundles were ... bundles by flowing water over them fit the empirical logarithmic law over a large range of velocity.

  2. Impact on Generator Reactive Power Limits on a Static Voltage Stability

    Directory of Open Access Journals (Sweden)

    TOVAR-GONZALEZ, E. A.

    2011-11-01

    Full Text Available Voltage stability margin in a power system is closely related with the availability of reactive power in the system. Therefore, adequate modeling of the reactive power sources becomes an important issue in this type of studies. The Minimum Singular Value of the load flow Jacobian matrix has been commonly used as a static voltage stability index. In this paper, such index is used to assess the influence on the static voltage stability limit of modeling the generators reactive power limits by its capability curve. Simulation results on a test system indicate that modeling the reactive power limits of the generating units by the simplified Qmin/Qmax approach, commonly used by most of the load flow programs, yields optimistic values for this voltage stability index.

  3. Direct detection of the parametrically generated half-harmonic voltage in a Josephson tunnel junction

    DEFF Research Database (Denmark)

    Mygind, Jesper; Pedersen, Niels Falsig; Sørensen, O. H.

    1976-01-01

    The first direct observation of the parametrically generated half-harmonic voltage in a Josephson tunnel junction is reported. A microwave signal at f=17.25 GHz is applied to the junction dc current biased at zero voltage such that the Josephson plasma resonance fp=f/2. Under these conditions a l...... a large-amplitude microwave signal is emitted at fp provided the input power exceeds a threshold value. The results are compared to existing theory. Applied Physics Letters is copyrighted by The American Institute of Physics.......The first direct observation of the parametrically generated half-harmonic voltage in a Josephson tunnel junction is reported. A microwave signal at f=17.25 GHz is applied to the junction dc current biased at zero voltage such that the Josephson plasma resonance fp=f/2. Under these conditions...

  4. 30 CFR 75.810 - High-voltage trailing cables; splices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage trailing cables; splices. 75.810... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.810 High-voltage trailing cables; splices. In the case of high-voltage cables used as trailing...

  5. 30 CFR 77.807-1 - High-voltage powerlines; clearances above ground.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage powerlines; clearances above... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.807-1 High-voltage powerlines; clearances above ground. High-voltage powerlines located above driveways, haulageways, and railroad tracks...

  6. 30 CFR 18.53 - High-voltage longwall mining systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage longwall mining systems. 18.53... and Design Requirements § 18.53 High-voltage longwall mining systems. (a) In each high-voltage motor-starter enclosure, with the exception of a controller on a high-voltage shearer, the disconnect device...

  7. 30 CFR 75.800 - High-voltage circuits; circuit breakers.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage circuits; circuit breakers. 75.800... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.800 High-voltage circuits; circuit breakers. High-voltage circuits entering the underground area...

  8. 30 CFR 75.812-2 - High-voltage power centers and transformers; record of examination.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage power centers and transformers... High-Voltage Distribution § 75.812-2 High-voltage power centers and transformers; record of examination... record shall be kept in a book approved by the Secretary. High-Voltage Longwalls Source: 67 FR 11001, Mar...

  9. 30 CFR 77.800 - High-voltage circuits; circuit breakers.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage circuits; circuit breakers. 77.800... COAL MINES Surface High-Voltage Distribution § 77.800 High-voltage circuits; circuit breakers. High-voltage circuits supplying power to portable or mobile equipment shall be protected by suitable circuit...

  10. 30 CFR 77.804 - High-voltage trailing cables; minimum design requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage trailing cables; minimum design... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.804 High-voltage trailing cables; minimum design requirements. (a) High-voltage trailing cables used in resistance grounded systems shall be...

  11. High Voltage Power Converter for Large Wind Turbine

    DEFF Research Database (Denmark)

    Sztykiel, Michal

    system operates at 20 kV level - identical as for the collector distribution network. Medium voltage operation allows the converter unit along with the filter to be installed on the base platform inside the tower. In this manner, more space in the nacelle can be flexibly accommodated by the mechanical...... application. System B consists of the generator-side 2-level converter, DC/DC boost unit and a grid-side NPC-3L converter. System C is made of a seriesconnected full-bridge cells on the generator-side, and a grid-side NPC-5L converter. The performance of the proposed topologies is analyzed both under...

  12. Unbalanced voltage faults: the impact on structural loads of doubly fed asynchronous generator wind turbines

    DEFF Research Database (Denmark)

    Barahona Garzón, Braulio; Cutululis, Nicolaos Antonio; Hansen, Anca Daniela

    2014-01-01

    by unbalanced voltage faults relative to those during normal operation; and to evaluate the potential for reducing structural loads with the control of the generator. The method applied is integrated dynamic analysis. Namely, dynamic analysis with models that consider the most important aeroelastic, electrical......This paper investigates the impact that unbalanced voltage faults have on wind turbine structural loads. In such cases, electromagnetic torque oscillations occur at two times the supply voltage frequency. The objectives of this work are to quantify wind turbine structural loads induced...

  13. Power electronic solutions for interfacing offshore wind turbine generators to medium voltage DC collection grids

    Science.gov (United States)

    Daniel, Michael T.

    Here in the early 21st century humanity is continuing to seek improved quality of life for citizens throughout the world. This global advancement is providing more people than ever with access to state-of-the-art services in areas such as transportation, entertainment, computing, communication, and so on. Providing these services to an ever-growing population while considering the constraints levied by continuing climate change will require new frontiers of clean energy to be developed. At the time of this writing, offshore wind has been proven as both a politically and economically agreeable source of clean, sustainable energy by northern European nations with many wind farms deployed in the North, Baltic, and Irish Seas. Modern offshore wind farms are equipped with an electrical system within the farm itself to aggregate the energy from all turbines in the farm before it is transmitted to shore. This collection grid is traditionally a 3-phase medium voltage alternating current (MVAC) system. Due to reactive power and other practical constraints, it is preferable to use a medium voltage direct current (MVDC) collection grid when siting farms >150 km from shore. To date, no offshore wind farm features an MVDC collection grid. However, MVDC collection grids are expected to be deployed with future offshore wind farms as they are sited further out to sea. In this work it is assumed that many future offshore wind farms may utilize an MVDC collection grid to aggregate electrical energy generated by individual wind turbines. As such, this work presents both per-phase and per-pole power electronic converter systems suitable for interfacing individual wind turbines to such an MVDC collection grid. Both interfaces are shown to provide high input power factor at the wind turbine while providing DC output current to the MVDC grid. Common mode voltage stress and circulating currents are investigated, and mitigation strategies are provided for both interfaces. A power sharing

  14. Solid-Body Fuse Developed for High- Voltage Space Power Missions

    Science.gov (United States)

    Dolce, James L.; Baez, Anastacio N.

    2001-01-01

    AEM Incorporated has completed the development, under a NASA Glenn Research Center contract, of a solid-body fuse for high-voltage power systems of satellites and spacecraft systems. High-reliability fuses presently defined by MIL-PRF-23419 do not meet the increased voltage and amperage requirements for the next generation of spacecraft. Solid-body fuses exhibit electrical and mechanical attributes that enable these fuses to perform reliably in the vacuum and high-vibration and -shock environments typically present in spacecraft applications. The construction and screening techniques for solid-body fuses described by MIL-PRF-23419/12 offer an excellent roadmap for the development of high-voltage solid-body fuses.

  15. Design and development of high voltage high power operational ...

    Indian Academy of Sciences (India)

    Normally power opamps can deliver current more than 50 mA and can operate on the supply voltage more than ±25 V. This paper gives the details of one of the power opamps developed to drive the Piezo Actuators for Active Vibration Control (AVC) of aircraft/aerospace structures. The designed power opamp will work on ...

  16. High-Voltage Clock Driver for Photon-Counting CCD Characterization

    Science.gov (United States)

    Baker, Robert

    2013-01-01

    A document discusses the CCD97 from e2v technologies as it is being evaluated at Goddard Space Flight Center's Detector Characterization Laboratory (DCL) for possible use in ultra-low background noise space astronomy applications, such as Terrestrial Planet Finder Coronagraph (TPF-C). The CCD97 includes a photoncounting mode where the equivalent output noise is less than one electron. Use of this mode requires a clock signal at a voltage level greater than the level achievable by the existing CCD (charge-coupled-device) electronics. A high-voltage waveform generator has been developed in code 660/601 to support the CCD97 evaluation. The unit generates required clock waveforms at voltage levels from -20 to +50 V. It deals with standard and arbitrary waveforms and supports pixel rates from 50 to 500 kHz. The system is designed to interface with existing Leach CCD electronics.

  17. Multiloop Rapid-Rise/Rapid Fall High-Voltage Power Supply

    Science.gov (United States)

    Bearden, Douglas

    2007-01-01

    A proposed multiloop power supply would generate a potential as high as 1.25 kV with rise and fall times rise-time, and fall-time requirements. The power supply would include a preregulator that would be used to program a voltage 1/30 of the desired output voltage. By means of a circuit that would include a pulse-width modulator (PWM), two voltage doublers, and a transformer having two primary and two secondary windings, the preregulator output voltage would be amplified by a factor of 30. A resistor would limit the current by controlling a drive voltage applied to field-effect transistors (FETs) during turn-on of the PWM. Two feedback loops would be used to regulate the high output voltage. A pulse transformer would be used to turn on four FETs to short-circuit output capacitors when the outputs of the PWM were disabled. Application of a 0-to-5-V square to a PWM shut-down pin would cause a 20-to-1,250-V square wave to appear at the output.

  18. Operational characteristics of a high voltage dense plasma focus

    Science.gov (United States)

    Woodall, D. M.

    1985-11-01

    A high voltage dense plasma focus powered by a single stage Marx bank was designed, built and operated. The maximum bank parameters are: voltage--120 kV, energy--20 kJ, short circuit current--600kA. The bank impedance is about 200 millohms. The plasma focus center electrode diameter is 1.27 cm. The outer electrode diameter is 10.16 cm. Rundown length is about 10 cm, corresponding to a bank quarter period of about 900 millohms ns. Rundown L is about 50 milliohms. The context of this work is established with a review of previous plasma focus theoretical, experimental and computational work and related topics. Theoretical motivation for high voltage operation is presented. The design, construction and operation of this device are discussed in detail. Results and analysis of measurements obtained are presented. Device operation was investigated primarily at 80 kV (9 kJ), with a gas fill of about 1 torr H2, plus 3-5 percent A. The following diagnostics were used: gun voltage and current measurements; filtered, time resolved x ray PIN measurements of the pinch region; time integrated x ray pinhole photographs of the pinch region; fast frame visible light photographs of the sheath during rundown; and B probe measurements of the current sheath shortly before collapse.

  19. Electronic Current Transducer (ECT) for high voltage dc lines

    Science.gov (United States)

    Houston, J. M.; Peters, P. H., Jr.; Summerayes, H. R., Jr.; Carlson, G. J.; Itani, A. M.

    1980-02-01

    The development of a bipolar electronic current transducer (ECT) for measuring the current in a high voltage dc (HVDC) power line at line potential is discussed. The design and construction of a free standing ECT for use on a 400 kV line having a nominal line current of 2000 A is described. Line current is measured by a 0.0001 ohm shunt whose voltage output is sampled by a 14 bit digital data link. The high voltage interface between line and ground is traversed by optical fibers which carry digital light signals as far as 300 m to a control room where the digital signal is converted back to an analog representation of the shunt voltage. Two redundant electronic and optical data links are used in the prototype. Power to operate digital and optical electronics and temperature controlling heaters at the line is supplied by a resistively and capacitively graded 10 stage cascade of ferrite core transformers located inside the hollow, SF6 filled, porcelain support insulator. The cascade is driven by a silicon controlled rectifier inverter which supplies about 100 W of power at 30 kHz.

  20. High transmembrane voltage raised by close contact initiates fusion pore

    Directory of Open Access Journals (Sweden)

    Bing Bu

    2016-12-01

    Full Text Available Membrane fusion lies at the heart of neuronal communication but the detailed mechanism of a critical step, fusion pore initiation, remains poorly understood. Here, through atomistic molecular dynamics simulations, a transient pore formation induced by a close contact of two apposed bilayers is firstly reported. Such a close contact gives rise to a high local transmembrane voltage that induces the transient pore formation. Through simulations on two apposed bilayers fixed at a series of given distances, the process in which two bilayers approaching to each other under the pulling force from fusion proteins for membrane fusion was mimicked. Of note, this close contact induced fusion pore formation is contrasted with previous reported electroporation under ad hoc applied external electric field or ionic charge in-balance. We show that the transmembrane voltage increases with the decrease of the distance between the bilayers. Below a critical distance, depending on the lipid composition, the local transmembrane voltage can be sufficiently high to induce the transient pores. The size of these pores is approximately 1~2 nm in diameter, which is large enough to allow passing of neurotransmitters. A resealing of the membrane pores resulting from the neutralization of the transmembrane voltage by ions through the pores was then observed. We also found that the membrane tension can either prolong the lifetime of transient pores or cause them to dilate for full collapse. This result provides a possible mechanism for fusion pore formation and regulation of pathway of fusion process.

  1. 30 CFR 18.54 - High-voltage continuous mining machines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage continuous mining machines. 18.54... and Design Requirements § 18.54 High-voltage continuous mining machines. (a) Separation of high-voltage components from lower voltage components. In each motor-starter enclosure, barriers, partitions...

  2. 30 CFR 75.705-2 - Repairs to energized surface high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Repairs to energized surface high-voltage lines... Repairs to energized surface high-voltage lines. An energized high-voltage surface line may be repaired... on power circuits with a phase-to-phase nominal voltage no greater than 15,000 volts; (3) Such...

  3. An improved direct feedback linearization technique for transient stability enhancement and voltage regulation of power generators

    Energy Technology Data Exchange (ETDEWEB)

    Kenne, Godpromesse [Laboratoire d' Automatique et d' Informatique Appliquee (LAIA), Departement de Genie Electrique, Universite de Dschang, B.P. 134 Bandjoun, Cameroun; Goma, Raphael; Lamnabhi-Lagarrigue, Francoise [Laboratoire des Signaux et Systemes (L2S), CNRS-SUPELEC, Universite Paris XI, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France); Nkwawo, Homere [Departement GEII, Universite Paris XIII, IUT Villetaneuse, 99 Avenue Jean Baptiste Clement, 93430 Villetaneuse (France); Arzande, Amir; Vannier, Jean Claude [Departement Energie, Ecole Superieure d' Electricite-SUPELEC, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France)

    2010-09-15

    In this paper, a simple improved direct feedback linearization design method for transient stability and voltage regulation of power systems is discussed. Starting with the classical direct feedback linearization technique currently applied to power systems, an adaptive nonlinear excitation control of synchronous generators is proposed, which is new and effective for engineering. The power angle and mechanical power input are not assumed to be available. The proposed method is based on a standard third-order model of a synchronous generator which requires only information about the physical available measurements of angular speed, active electric power and generator terminal voltage. Experimental results of a practical power system show that fast response, robustness, damping, steady-state and transient stability as well as voltage regulation are all achieved satisfactorily. (author)

  4. High-voltage plasma interactions calculations using NASCAP/LEO

    Science.gov (United States)

    Mandell, M. J.; Katz, I.

    1990-01-01

    This paper reviews four previous simulations (two laboratory and two space-flight) of interactions of a high-voltage spacecraft with a plasma under low-earth orbit conditions, performed using a three-dimensional computer code NASCAP/LEO. Results show that NASCAP/LEO can perform meaningful simulations of high-voltage plasma interactions taking into account three-dimensional effects of geometry, spacecraft motion, and magnetic field. Two new calculations are presented: (1) for current collection by 1-mm pinholes in wires (showing that a pinhole in a wire can collect far more current than a similar pinhole in a flat plate); and (2) current collection by Charge-2 mother vehicle launched in December 1985. It is shown that the Charge-2 calculations predicted successfully ion collection at negative bias, the floating potential of a probe outside or inside the sheath under negative bias conditions, and magnetically limited electron collection under electron beam operation at high altitude.

  5. Highly Reliable NPP Instrumentation Using Constant Voltage Feedback Circuits

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Seung J.; Choi, Bo H.; Kim, Ji H.; Rim, Chun T. [KAIST, Daejeon (Korea, Republic of)

    2014-08-15

    A highly reliable nuclear power plant (NPP) instrumentation using constant voltage feedback circuits is proposed. Contrary to conventional NPP instrumentation, two operational amplifiers are used at auxiliary building to supply constant DC voltage across the potentiometer or wheatstone bridge type sensors, such as resistance temperature detectors (RTD) and strain gauges. The proposed constant voltage feedback circuits maintain its output voltage as constant regardless of the length of lead wire from the auxiliary building to the sensors. A detail analysis of the proposed feedback circuits and design procedures including the internal resistance and parasitic LC components of lead wire are presented. A prototype with lumped RLC values for modeling lead wires is fabricated and experimentally verified to supply constant 10V up to 200m distance under 0.8% error. Due to its versatile characteristics with cost effective structure, the proposed scheme can be generally extended to pressure meters and water-level recorders to guarantee robust measurements without conventional current transducers under severe accidents.

  6. Dynamic performance of doubly-fed induction generator stator flux during consecutive grid voltage variations

    DEFF Research Database (Denmark)

    Zhu, Rongwu; Chen, Zhe; Wu, Xiaojie

    2015-01-01

    For the grid-connected doubly-fed induction generator (DFIG)-based wind turbine, because of the stator connected to the grid directly, the stator flux easily suffers from the effects of grid voltage variations, such as grid disturbances and grid faults. Moreover, since the magnetic field is excited...... reveal that the stator flux can be accumulated by the consecutive variations of the stator voltage, and the instants of grid voltage variations can lead to different amplitudes of the stator flux. In addition, the conventional vector control strategy and the active damping strategy are compared...... by the rotor current, stator flux is also affected by the rotor current. Therefore this study systematically studies the dynamic performances of stator flux under consecutive grid voltage variations and varying rotor currents, and its influence on the performances of the DFIG during grid faults. The analyses...

  7. Low voltage ride-Through strategy based on virtual synchronous generator control

    Science.gov (United States)

    Guo, L.; Su, J. H.; Yu, L.; Lai, J. D.

    2017-06-01

    Inverters controlled in virtual synchronous generator(VSG) method is able to operate in both grid-connected mode and islanding mode. Due to this characteristic, this paper put forwards a low voltage ride-through(LVRT) strategy which is based on VSG control. If the grid voltage sags, VSG can limit the output current amplitude and meanwhile inject reactive power to the grid. Once the voltage drop time exceeds the maximum ride-through time, VSG would smoothly switch to islanding mode and continues to carry loads independently. The proposed strategy achieves a control algorithm unity between normal operating and grid voltage sag status in grid-connected mode. Simulations can support the validity of the strategy.

  8. Autonomous Voltage Security Regions to Prevent Cascading Trip Faults in Wind Turbine Generators

    DEFF Research Database (Denmark)

    Niu, Tao; Guo, Qinglai; Sun, Hongbin

    2016-01-01

    Cascading trip faults in large-scale wind power centralized integration areas bring new challenges to the secure operation of power systems. In order to deal with the complexity of voltage security regions and the computation difficulty, this paper proposes an autonomous voltage security region...... (AVSR) for each wind farm and the point of common coupling (PCC) substation, whose voltage can be controlled in a decoupled way. The computation of the AVSR can be completed using a stepwise search method exchanging voltage and power information between the control center and the wind farms. At each...... wind farm, an AVSR is determined to guarantee the normal operation of each wind turbine generator (WTG), while in the control center, each region is designed in order to guarantee secure operation both under normal conditions and after an N-1 contingency. A real system in Northern China was used...

  9. Special features of large-size resistors for high-voltage pulsed installations

    Science.gov (United States)

    Minakova, N. N.; Ushakov, V. Ya.

    2017-12-01

    Many structural materials in pulsed power engineering operate under extreme conditions. For example, in high-voltage electrophysical installations among which there are multistage high-voltage pulse generators (HVPG), rigid requirements are imposed on characteristics of solid-state resistors that are more promising in comparison with widely used liquid resistors. Materials of such resistors shall be able to withstand strong electric fields, operate at elevated temperatures, in transformer oil, etc. Effective charge of high-voltage capacitors distributed over the HVPG steps (levels) requires uniform voltage distribution along the steps of the installation that can be obtained using large-size resistors. For such applications, polymer composite materials are considered rather promising. They can work in transformer oil and have small mass in comparison with bulky resistors on inorganic basis. This allows technical solutions already developed and implemented in HVPG with liquid resistors to be employed. This paper is devoted to the solution of some tasks related to the application of filled polymers in high-voltage engineering.

  10. A high voltage method for measuring low capacitance for tomography.

    Science.gov (United States)

    Lu, Decai; Shao, Fuqun; Guo, Zhiheng

    2009-05-01

    Low capacitance measurement is involved in many industrial applications, especially in the applications of electrical capacitance tomography (ECT). Most of the low capacitance measurement circuits employ an ac-based method or a charge/discharge method because of high sensitivity, high resolution, and immunity to stray capacitance; and its excitation or charge voltage are not more than 20 V. When ECT techniques for large industrial equipment such as blast furnaces or grain barns are explored, the existing methods for measuring low capacitance have some limitations. This paper proposes a high excitation voltage ac-based method for measuring low capacitance to improve the resolution of measurement. The method uses a high excitation voltage of several hundred volts and a transformer ratio arms as the C/V transducer. Experimental results indicate that the new method has a resolution of 0.005 fF, a good stability (about 0.003 fF over 4 h) and linearity (0.9992).

  11. High-voltage integrated transmitting circuit with differential driving for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Færch, Kjartan Ullitz

    2016-01-01

    In this paper, a high-voltage integrated differential transmitting circuit for capacitive micromachined ultrasonic transducers (CMUTs) used in portable ultrasound scanners is presented. Due to its application, area and power consumption are critical and need to be minimized. The circuitry...... is designed and implemented in AMS 0.35 μ m high-voltage process. Measurements are performed on the fabricated integrated circuit in order to assess its performance. The transmitting circuit consists of a low-voltage control logic, pulse-triggered level shifters and a differential output stage that generates...... conditions is 0.936 mW including the load. The integrated circuits measured prove to be consistent and robust to local process variations by measurements....

  12. Using the Direct Search Method for Optimal Dispatch of Distributed Generation in a Medium-Voltage Microgrid

    Directory of Open Access Journals (Sweden)

    Wei-Tzer Huang

    2014-12-01

    Full Text Available This paper proposes a simple and efficient approach for the optimal dispatch in a medium-voltage microgrid (MG with various types of distributed generation (DG. The fuel costs generated by these DGs are determined using quadratic and linear functions dependent on the types of DGs. Instead of using the traditional Lagrange multiplier method for power system economic dispatch, the proposed direct search method (DSM approach is able to handle several inequality constraints without introducing any multipliers and furthermore it can solve the non-derivative problems or the fuel cost functions being much more complicated. Accordingly, the DSM is proposed for determining the optimal dispatch of MGs with various types of DG to minimize generation costs under grid-tied and autonomous operations. Results demonstrate that the proposed DSM is a highly suitable and simple approach to determining the optimal dispatch in medium-voltage MGs with various types of DG.

  13. Light-weight DC to very high voltage DC converter

    Science.gov (United States)

    Druce, R.L.; Kirbie, H.C.; Newton, M.A.

    1998-06-30

    A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current. 1 fig.

  14. DISTRIBUTION OF HIGH-FREQUENCY VOLTAGE IN DISTRIBUTION NETWORK

    Directory of Open Access Journals (Sweden)

    M. I. Polujanov

    2005-01-01

    Full Text Available The paper reveals a method for remote determination of a location of single-phase short circuit on the ground in distribution networks with isolated neutral point. The method is based on measurement of high-frequency (a tone  range inter-phase voltage at all transformer substations and it creates preconditions for automation of searching process.  

  15. Pollution Maintenance Techniques in Coastal High Voltage Installations

    OpenAIRE

    Pyrgioti, E.; I. Vitellas; Thalassinakis, E.; D. Pylarinos; K. Siderakis

    2011-01-01

    Pollution of outdoor high voltage insulators is a common problem for utilities, with a considerable impact to power system reliability. In an effort to prevent possible flashovers due to pollution, many methods have been applied, aiming to improve the insulation performance, either by suppressing the formation of surface conductivity or by increasing the possible insulation level. In the case of substations, the selection of the appropriate technique is complex due to certain issues correlate...

  16. THE EFFECT OF LIGHTNING ON HIGH VOLTAGE ELECTRICAL SUBSTATIONS’ LOW VOLTAGE SYSTEMS

    Directory of Open Access Journals (Sweden)

    M. I. Fursanov

    2016-01-01

    Full Text Available The article presents the results of studies of the effects of lightning on low voltage systems of high voltage electrical substations with outdoor switchgears of 110 kV. The topicality of research is associated with a wide spreading of such substations as well as with a high reliability requirements of their work and, also, with their widespread distribution and high probability of lightning strikes to the substation or around it. The highest probable and the most dangerous effects of lightning on low voltage systems of a substation are determined on the basis of critical review and special literature analysis and, also, of systematization of practical information that had been collected during the survey of operating substations. Adequate physical models were developed for the list of hazardous effects based on physical processes of lightning. A model of each effect was studied on the basis of the sensitivity theory. The accuracy and adequacy of the models were verified by means of comparison of calculation results for the models under investigation with the results of calculations fulfilled in accordance with specialized programs, as well as from practical or theoretical data obtained by other authors. The factors that had been included in the models were studied and were defined in accordance with their nature (natural or artificial, the range of possible values in a substation was determined; the coefficients of elasticity were calculated. The obtained results enable to ascertain the contribution of the factor in the effect of lightning and the ability to control the factor. The relationship between the factors and the effects of lightning are shown as graphs. For practical application the information, obtained as the result of the research, was organized in the form of checklists that can be applied when collecting baseline information to develop the lightning protection of the substation, to examine the existing lightning protection, to

  17. Distributed Control of Battery Energy Storage Systems for Voltage Regulation in Distribution Networks with High PV Penetration

    DEFF Research Database (Denmark)

    Zeraati, Mehdi; Golshan, Mohamad Esmaeil Hamedani; Guerrero, Josep M.

    2017-01-01

    issues of distribution networks. In this paper, the battery energy storage (BES) systems are used in order to solve the voltage rise during the peak PV generation as well as the voltage drop while meeting the peak load. A coordinated control strategy is proposed to regulate the charge/discharge of BESs......The voltage rise problem in low voltage (LV) distribution networks with high penetration of photovoltaic (PV) resources is one of the most important challenges in the development of these renewable resources since it may prevent the maximum PV penetration considering the reliability and security...... using a combination of the local droop based control method and a distributed control scheme which ensures the voltages of feeder remain within allowed limits. Therefore, two different consensus algorithms are used: The first algorithm determines the BESs participation in voltage regulation in terms...

  18. Rad-Hard, Miniaturized, Scalable, High-Voltage Switching Module for Power Applications Rad-Hard, Miniaturized

    Science.gov (United States)

    Adell, Philippe C.; Mojarradi, Mohammad; DelCastillo, Linda Y.; Vo, Tuan A.

    2011-01-01

    A paper discusses the successful development of a miniaturized radiation hardened high-voltage switching module operating at 2.5 kV suitable for space application. The high-voltage architecture was designed, fabricated, and tested using a commercial process that uses a unique combination of 0.25 micrometer CMOS (complementary metal oxide semiconductor) transistors and high-voltage lateral DMOS (diffusion metal oxide semiconductor) device with high breakdown voltage (greater than 650 V). The high-voltage requirements are achieved by stacking a number of DMOS devices within one module, while two modules can be placed in series to achieve higher voltages. Besides the high-voltage requirements, a second generation prototype is currently being developed to provide improved switching capabilities (rise time and fall time for full range of target voltages and currents), the ability to scale the output voltage to a desired value with good accuracy (few percent) up to 10 kV, to cover a wide range of high-voltage applications. In addition, to ensure miniaturization, long life, and high reliability, the assemblies will require intensive high-voltage electrostatic modeling (optimized E-field distribution throughout the module) to complete the proposed packaging approach and test the applicability of using advanced materials in a space-like environment (temperature and pressure) to help prevent potential arcing and corona due to high field regions. Finally, a single-event effect evaluation would have to be performed and single-event mitigation methods implemented at the design and system level or developed to ensure complete radiation hardness of the module.

  19. Nanosecond pulsed power generator for a voltage amplitude up to 300 kV and a repetition rate up to 16 Hz for fine disintegration of quartz

    Energy Technology Data Exchange (ETDEWEB)

    Krastelev, E. G., E-mail: ekrastelev@yandex.ru; Sedin, A. A.; Tugushev, V. I. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2015-12-15

    A generator of high-power high-voltage nanosecond pulses is intended for electrical discharge disintegration of mineral quartz and other nonconducting minerals. It includes a 320 kV Marx pulsed voltage generator, a high-voltage glycerin-insulated coaxial peaking capacitor, and an output gas spark switch followed by a load, an electric discharge disintegration chamber. The main parameters of the generator are as follows: a voltage pulse amplitude of up to 300 kV, an output impedance of ≈10 Ω, a discharge current amplitude of up to 25 kA for a half-period of 80–90 ns, and a pulse repetition rate of up to 16 Hz.

  20. Prototype high voltage bushing: Configuration to its operational demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Sejal, E-mail: sshah@iter-india.org [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar 382428 (India); Sharma, D. [Institute for Plasma Research, Bhat, Gandhinagar 382428 (India); Parmar, D.; Tyagi, H.; Joshi, K.; Shishangiya, H.; Bandyopadhyay, M.; Rotti, C.; Chakraborty, A. [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar 382428 (India)

    2016-12-15

    High Voltage Bushing (HVB) is the key component of Diagnostic Neutral Beam (DNB) system of ITER as it provides access to high voltage electrical, hydraulic, gas and diagnostic feedlines to the beam source with isolation from grounded vessel. HVB also provides primary vacuum confinement for the DNB system. Being Safety Important Class (SIC) component of ITER, it involves several configurational, technological and operational challenges. To ensure its operational performance & reliability, particularly electrostatic behavior, half scale down Prototype High Voltage Bushing (PHVB) is designed considering same design criteria of DNB HVB. Design optimization has been carried out followed by finite element (FE) analysis to obtain DNB HVB equivalent electric stress on different parts of PHVB, taking into account all design, manufacturing & space constraints. PHVB was tested up to 60 kV without breakdown, which validates its design for the envisaged operation of 50 kV DC. This paper presents the design of PHVB, FEA validation, manufacturing constraints, experimental layout with interfacing auxiliary systems and operational results related to functional performance.

  1. Health problems from radiation of high-voltage facilities

    Directory of Open Access Journals (Sweden)

    Hossein Ali Yousefi Rizi

    2013-01-01

    Full Text Available Aims: The aim of this study was to survey the health problems caused by exposure to high-voltage facility radiation. Materials and Methods: Sampling included workers exposed to electromagnetic fields at high-voltage facilities. The strength of the electric and magnetic fields was determined by a field meter. A questionnaire was used to evaluate the prevalence of subjective and psychological symptoms. Statistical descriptive used and data analyzed by a Student′s t-tests. Results: This study indicates that increased symptoms among the exposed workers including depression, anxiety, hostility, paranoia, inter-sensitivity, and obsession-compulsion. Some of the self-reported symptoms were, headache (53.5%, fatigue (35.6%, difficulties in concentration (32.5%, vertigo/dizziness (30.4%, attention disorders (28.8%, nervousness (28.1%, and palpitations (14.7%. A significant relationship was observed between the exposure to the electromagnetic field and psychological symptoms (P < 0.05. Conclusion: Radiation of high-voltage facilities probably increased the risk of mental disorders and intensified them in susceptible workers, especially depression. This finding confirmed the results obtained in provocative studies that indicated an increase in the risk of psychological symptoms, which was put forth by several investigators Observation of occupational health and other control measures play an important role in decreasing the symptoms.

  2. Solar powered high voltage energization for vehicular exhaust cleaning: A step towards possible retrofitting in vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Rajanikanth, B.S.; Mohapatro, Sankarsan [High Voltage Lab, Indian Institute of Science, Bangalore-560012 (India); Umanand, L. [CEDT, Indian Institute of Science, Bangalore-560012 (India)

    2009-03-15

    This paper proposes a novel way of generating high voltage for electric discharge plasma in controlling NO{sub x} emission in diesel engine exhaust. A solar powered high frequency electric discharge topology has been suggested that will improve the size and specific energy density required when compared to the traditional repetitive pulse or 50 Hz AC energization. This methodology has been designed, fabricated and experimentally verified by conducting studies on real diesel engine exhaust. (author)

  3. High Voltage Power Supply With High Output Current and Low Power Consumption for Photomultiplier Tubes

    Science.gov (United States)

    Cunha, José Paulo V. S.; Begalli, Marcia; Bellar, Maria Dias

    2012-04-01

    In some applications, photomultiplier tubes (PMTs) are powered by battery based circuits, where the available energy is severely limited. The most simple approach to design high voltage power supplies (HVPS) for PMTs has considered resistive voltage dividers in order to bias the dynodes. However, this approach usually results in high power losses and, consequently, this undermines the PMT performance. In this work, the proposed solution is the use of a power circuit based on the forward converter connected to a transformer built with several secondary windings. Each secondary voltage is rectified and filtered to eliminate voltage ripple. Each dynode voltage is supplied by a rectified secondary voltage. The proposed topology provides low power consumption as well as low sensitivity of the PMT gain with respect to the dynode currents. Taking into account the Waste Electrical and Electronic Equipment Directive (WEEE), this HVPS has been designed to allow the recycling of old PMTs.

  4. PHENIX Resistive Plate Chambers High Voltage Performance Analysis

    Science.gov (United States)

    Towell, Marshall; Phenix Collaboration

    2013-10-01

    The PHENIX experiment at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory studies polarized proton-proton collisions to better understand the spin structure of the proton. While RHIC is operating there are millions of collisions each second, but the PHENIX data acquisition system can only record a few thousand each second. To help select the rare events of interest, a new forward trigger has been commissioned that includes four stations of Resistive Plate Chambers (RPCs). During the most recent RHIC run, significant polarized proton-proton data were recorded with the new trigger for the first time. The RPC high voltage was recorded and studied for each module and each run. Every physics run was classified into one of four categories depending on its high voltage conditions, including the number of trips and the number and magnitude of mismatches between the HV set point and readback voltage. Each condition that was required to consider a run to have good HV was investigated systematically to determine the appropriate set points. The methods and results of this systematic study will be presented. This research was supported in part by the DOE under grant number DE-FG03-94ER40860.

  5. Voltage Control Scheme with Distributed Generation and Grid Connected Converter in a DC Microgrid

    Directory of Open Access Journals (Sweden)

    Jong-Chan Choi

    2014-10-01

    Full Text Available Direct Current (DC microgrids are expected to become larger due to the rapid growth of DC energy sources and power loads. As the scale of the system expends, the importance of voltage control will be increased to operate power systems stably. Many studies have been performed on voltage control methods in a DC microgrid, but most of them focused only on a small scale microgrid, such as a building microgrid. Therefore, a new control method is needed for a middle or large scale DC microgrid. This paper analyzes voltage drop problems in a large DC microgrid and proposes a cooperative voltage control scheme with a distributed generator (DG and a grid connected converter (GCC. For the voltage control with DGs, their location and capacity should be considered for economic operation in the systems. Accordingly, an optimal DG allocation algorithm is proposed to minimize the capacity of a DG for voltage control in DC microgrids. The proposed methods are verified with typical load types by a simulation using MATLAB and PSCAD/EMTDC.

  6. Grid Voltage Synchronization for Distributed Generation Systems under Grid Fault Conditions

    DEFF Research Database (Denmark)

    Luna, Alvaro; Rocabert, J.; Candela, I.

    2015-01-01

    The actual grid code requirements for the grid connection of distributed generation systems, mainly wind and PV systems, are becoming very demanding. The Transmission System Operators (TSOs) are especially concerned about the Low Voltage Ride Through requirements. Solutions based on the installat...

  7. Low Voltage Ride-Through of Variable Speed Wind Turbines with Permanent Magnet Synchronous Generator

    DEFF Research Database (Denmark)

    Hu, Weihao; Chen, Zhe; Wang, Yue

    2009-01-01

    This paper presents a simulation model of a MW-level variable speed wind turbine with a permanent magnet synchronous generator (PMSG) and a full-scale converter developed in the simulation tool of PSCAD/EMTDC. The low voltage ride-through (LVRT) capability of the wind turbine is investigated. A new...

  8. Synchronous Generator Model with Fractional Order Voltage Regulator PIbDa

    Directory of Open Access Journals (Sweden)

    Dariusz Spałek

    2015-06-01

    Full Text Available Synchronous generator together with excitation circuit, voltage controller and system stabilizer constitute nonlinear ordinary differential equations set. The nonlinearity of differential equations set results from magnetic circuits saturation. One of the most important, from the electric energy distribution point of view, is the influence of voltage control applied on the generator voltage. There could be applied regulator either classical PID or fractional of type PIbDa which bases on the so-called fractional derivative idea. Numerical solutions of nonlinear differential equations set, that takes into account both magnetic circuits saturation and fractional regulator PIbDa, lead to decisions either to accept or to reject the chosen parameters. The sensibility of generator work on chosen fractional regulator parameters is the main aim of this paper. With the help of C++ program provided the most important states of work (short–circuit, setting voltage change, reactive power rejection can be analyzed basing on the accepted model of synchronous generator such as (1,1, (2,2 or (3,3.

  9. Robust Current Control of Doubly Fed Wind Turbine Generator under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Wang, Yun; Gong, Wenming; Wu, Qiuwei

    2014-01-01

    This paper presents the design of a H ∞ current controller for doubly fed induction generators (DFIGs) in order to maintain stable operation under unbalanced voltage conditions. The H ∞ current controller has a multi-input and multi-output (MIMO) structure and is designed using the loop shaping...

  10. Experimental validation of a high voltage pulse measurement method.

    Energy Technology Data Exchange (ETDEWEB)

    Cular, Stefan; Patel, Nishant Bhupendra; Branch, Darren W.

    2013-09-01

    This report describes X-cut lithium niobates (LiNbO3) utilization for voltage sensing by monitoring the acoustic wave propagation changes through LiNbO3 resulting from applied voltage. Direct current (DC), alternating current (AC) and pulsed voltage signals were applied to the crystal. Voltage induced shift in acoustic wave propagation time scaled quadratically for DC and AC voltages and linearly for pulsed voltages. The measured values ranged from 10 - 273 ps and 189 ps 2 ns for DC and non-DC voltages, respectively. Data suggests LiNbO3 has a frequency sensitive response to voltage. If voltage source error is eliminated through physical modeling from the uncertainty budget, the sensors U95 estimated combined uncertainty could decrease to ~0.025% for DC, AC, and pulsed voltage measurements.

  11. A High Voltage Swing 1.9 GHz PA in Standard CMOS

    NARCIS (Netherlands)

    Aartsen, W.A.J.; Annema, Anne J.; Nauta, Bram

    A circuit technique for RF power amplifiers that reliably handle voltage peaks well above the nominal supply voltage is presented. To achieve this high-voltage tolerance the circuit implements switched-cascode transistors that yield reliable operation for voltages up to 7V at RF frequencies in a

  12. Consideration of Reactor Installation to Mitigate Voltage Rise Caused by the Connection of a Renewable Energy Generator

    Directory of Open Access Journals (Sweden)

    Yeonho Ok

    2017-03-01

    Full Text Available This paper describes the detailed analysis of a reactor application for a power plant to mitigate the voltage rise of a distribution line (DL caused by the connection of distributed resources (DRs. The maximum capacity of renewable energy generators (REGs that meets the acceptable voltage rise of a DL and the necessary capacity of the reactor to mitigate that voltage rise according to the different types of REGs are analyzed. The re-coordination of a protection relay and the loss of generation revenue as well as the installation location of a reactor are described. Finally, the ON/OFF conditions of the reactor, such as the magnitudes of the grid voltage and generator voltage, and the duration time of the voltage rise are analyzed. As the voltage rise is mitigated and self-limited in small power plants, it is confirmed that the capacity of the DRs connected to the DL can be increased through a field demonstration.

  13. Impact of Solar Array Designs on High Voltage Operations

    Science.gov (United States)

    Brandhorst, Henry W., Jr.; Ferguson, Dale; Piszczor, Mike; ONeill, Mark

    2006-01-01

    As power levels of advanced spacecraft climb above 25 kW, higher solar array operating voltages become attractive. Even in today s satellites, operating spacecraft buses at 100 V and above has led to arcing in GEO communications satellites, so the issue of spacecraft charging and solar array arcing remains a design problem. In addition, micrometeoroid impacts on all of these arrays can also lead to arcing if the spacecraft is at an elevated potential. For example, tests on space station hardware disclosed arcing at 75V on anodized A1 structures that were struck with hypervelocity particles in Low Earth Orbit (LEO) plasmas. Thus an understanding of these effects is necessary to design reliable high voltage solar arrays of the future, especially in light of the Vision for Space Exploration of NASA. In the future, large GEO communication satellites, lunar bases, solar electric propulsion missions, high power communication systems around Mars can lead to power levels well above 100 kW. As noted above, it will be essential to increase operating voltages of the solar arrays well above 80 V to keep the mass of cabling needed to carry the high currents to an acceptable level. Thus, the purpose of this paper is to discuss various solar array approaches, to discuss the results of testing them at high voltages, in the presence of simulated space plasma and under hypervelocity impact. Three different types of arrays will be considered. One will be a planar array using thin film cells, the second will use planar single or multijunction cells and the last will use the Stretched Lens Array (SLA - 8-fold concentration). Each of these has different approaches for protection from the space environment. The thin film cell based arrays have minimal covering due to their inherent radiation tolerance, conventional GaAs and multijunction cells have the traditional cerium-doped microsheet glasses (of appropriate thickness) that are usually attached with Dow Corning DC 93-500 silicone

  14. Synthesis of Voltages of Multiple Uniform PWM, Generated by Trapezoidal and Sinusoidal Functions

    Directory of Open Access Journals (Sweden)

    A. G. Ctryzhniou

    2013-01-01

    Full Text Available The problem of synthesis and qualitative estimation of the harmonic composition of voltages of multiple uniform PWM pulses generated by trapezoidal and sinusoidal functions is considered. Analytical expressions for PWM pulses parameters ai  and ti have been received and they can be used for program-based generation of multiple uniform PWM, determination of n-harmonic magnitude in pulse-width regulation and AC motor operation simulation.

  15. Impacts of distributed generation on low-voltage distribution network protection

    OpenAIRE

    Ogden, Richard; Yang, Jin

    2015-01-01

    This paper reports work of a MEng student final year project, which looks in detail at the impacts that distributed generation can have on existing low-voltage distribution network protection systems. After a review of up-to-date protection issues, this paper will investigate several key issues that face distributed generation connections when it comes to network protection systems. These issues include, the blinding of protection systems, failure to automatically reclose, unintentional islan...

  16. Temperature and Voltage Offsets in High-ZT Thermoelectrics

    Science.gov (United States)

    Levy, George S.

    2017-10-01

    Thermodynamic temperature can take on different meanings. Kinetic temperature is an expectation value and a function of the kinetic energy distribution. Statistical temperature is a parameter of the distribution. Kinetic temperature and statistical temperature, identical in Maxwell-Boltzmann statistics, can differ in other statistics such as those of Fermi-Dirac or Bose-Einstein when a field is present. Thermal equilibrium corresponds to zero statistical temperature gradient, not zero kinetic temperature gradient. Since heat carriers in thermoelectrics are fermions, the difference between these two temperatures may explain voltage and temperature offsets observed during meticulous Seebeck measurements in which the temperature-voltage curve does not go through the origin. In conventional semiconductors, temperature offsets produced by fermionic electrical carriers are not observable because they are shorted by heat phonons in the lattice. In high-ZT materials, however, these offsets have been detected but attributed to faulty laboratory procedures. Additional supporting evidence for spontaneous voltages and temperature gradients includes data collected in epistatic experiments and in the plasma Q-machine. Device fabrication guidelines for testing the hypothesis are suggested including using unipolar junctions stacked in a superlattice, alternating n/n + and p/p + junctions, selecting appropriate dimensions, doping, and loading.

  17. New perspectives in vacuum high voltage insulation. II. Gas desorption

    CERN Document Server

    Diamond, W T

    1998-01-01

    An examination has been made of gas desorption from unbaked electrodes of copper, niobium, aluminum, and titanium subjected to high voltage in vacuum. It has been shown that the gas is composed of water vapor, carbon monoxide, and carbon dioxide, the usual components of vacuum outgassing, plus an increased yield of hydrogen and light hydrocarbons. The gas desorption was driven by anode conditioning as the voltage was increased between the electrodes. The gas is often desorbed as microdischarges-pulses of a few to hundreds of microseconds-and less frequently in a more continuous manner without the obvious pulsed structure characteristic of microdischarge activity. The quantity of gas released was equivalent to many monolayers and consisted mostly of neutral molecules with an ionic component of a few percent. A very significant observation was that the gas desorption was more dependent on the total voltage between the electrodes than on the electric field. It was not triggered by field-emitted electrons but oft...

  18. Simple, compact, and low cost CO2 laser driven by fast high voltage solid state switch for industrial application

    Science.gov (United States)

    Tanaka, Miyu; Tei, Masaya; Uno, Kazuyuki; Nakano, Hitoshi

    2017-02-01

    A longitudinally excited CO2 laser driven with a reverse recovery characteristics of high voltage diode has been developed. A diode is used to control the high voltage pulse as an opening switch. Power supply for longitudinally excited CO2 laser is composed of a pulse generator, transformer, capacitor, and a diode, is very simple. Laser oscillation has been successfully achieved, several tens of mJ in laser energy has been obtained.

  19. SEMICONDUCTOR DEVICES: A novel high voltage start up circuit for an integrated switched mode power supply

    Science.gov (United States)

    Hao, Hu; Xingbi, Chen

    2010-09-01

    A novel high voltage start up circuit for providing an initial bias voltage to an integrated switched mode power supply (SMPS) is presented. An enhanced mode VDMOS transistor, the gate of which is biased by a floating p-island, is used to provide start up current and sustain high voltage. An NMOS transistor having a high source to ground breakdown voltage is included to extend the bias voltage range to the SMPS. Simulation results indicate that the high voltage start up circuit can start and restart as designed. The proposed structure is believed to be more energy saving and cost-effective compared with other solutions.

  20. Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy

    CERN Document Server

    Krieger, A.; Catherall, R.; Hochschulz, F.; Kramer, J.; Neugart, R.; Rosendahl, S.; Schipper, J.; Siesling, E.; Weinheimer, Ch.; Yordanov, D.T.; Nortershauser, W.

    2011-01-01

    A high-voltage divider with accuracy at the ppm level and collinear laser spectroscopy were used to calibrate the highvoltage installation at the radioactive ion beam facility ISOLDE at CERN. The accurate knowledge of this voltage is particularly important for collinear laser spectroscopy measurements. Beam velocity measurements using frequencycomb based collinear laser spectroscopy agree with the new calibration. Applying this, one obtains consistent results for isotope shifts of stable magnesium isotopes measured using collinear spectroscopy and laser spectroscopy on laser-cooled ions in a trap. The long-term stability and the transient behavior during recovery from a voltage dropout were investigated for the different power supplies currently applied at ISOLDE.

  1. Kinetics of charged particles in a high-voltage gas discharge in a nonuniform electrostatic field

    Energy Technology Data Exchange (ETDEWEB)

    Kolpakov, V. A., E-mail: kolpakov683@gmail.com; Krichevskii, S. V.; Markushin, M. A. [Korolev Samara National Research University (Russian Federation)

    2017-01-15

    A high-voltage gas discharge is of interest as a possible means of generating directed flows of low-temperature plasma in the off-electrode space distinguished by its original features [1–4]. We propose a model for calculating the trajectories of charges particles in a high-voltage gas discharge in nitrogen at a pressure of 0.15 Torr existing in a nonuniform electrostatic field and the strength of this field. Based on the results of our calculations, we supplement and refine the extensive experimental data concerning the investigation of such a discharge published in [1, 2, 5–8]; good agreement between the theory and experiment has been achieved. The discharge burning is initiated and maintained through bulk electron-impact ionization and ion–electron emission. We have determined the sizes of the cathode surface regions responsible for these processes, including the sizes of the axial zone involved in the discharge generation. The main effect determining the kinetics of charged particles consists in a sharp decrease in the strength of the field under consideration outside the interelectrode space, which allows a free motion of charges with specific energies and trajectories to be generated in it. The simulation results confirm that complex electrode systems that allow directed plasma flows to be generated at a discharge current of hundreds or thousands of milliamperes and a voltage on the electrodes of 0.3–1 kV can be implemented in practice [3, 9, 10].

  2. Low Voltage Ride-Through Capability Solutions for Permanent Magnet Synchronous Wind Generators

    Directory of Open Access Journals (Sweden)

    Victor F. Mendes

    2016-01-01

    Full Text Available Due to the increasing number of wind power plants, several countries have modified their grid codes to include specific requirements for the connection of this technology to the power system. One of the requirements is the ride-through fault capability (RTFC, i.e., the system capability to sustain operation during voltage sags. In this sense, the present paper intends to investigate the behavior of a full-converter wind generator with a permanent magnet synchronous machine during symmetrical and asymmetrical voltage sags. Two solutions to improve the low voltage ride-through capability (LVRT of this technology are analyzed: discharging resistors (brake chopper and resonant controllers (RCs. The design and limitations of these solutions and the others proposed in the literature are discussed. Experimental results in a 34 kW test bench, which represents a scaled prototype of a real 2 MW wind conversion system, are presented.

  3. ELABORATION OF HIGH-VOLTAGE PULSE INSTALLATIONS AND PROVIDING THEIR OPERATION PROTECTIVE MEASURES

    Directory of Open Access Journals (Sweden)

    А. М. Hashimov

    2016-01-01

    Full Text Available The article presents design engineering methods for the high-voltage pulse installations of technological purpose for disinfection of drinking water, sewage, and edible liquids by high field micro- and nanosecond pulsing exposure. Designing potentialities are considered of the principal elements of the high-voltage part and the discharge circuit of the installations towards assuring the best efficient on-load utilization of the source energy and safe operation of the high-voltage equipment. The study shows that for disinfection of drinking water and sewage it is expedient to apply microsecond pulse actions causing the electrohydraulic effect in aqueous media with associated complex of physical processes (ultraviolet emission, generation of ozone and atomic oxygen, mechanical compression waves, etc. having detrimental effect on life activity of the microorganisms. In case of disinfecting edible liquids it is recommended to use the nanosecond pulses capable of straight permeating the biological cell nucleus, inactivating it. Meanwhile, the nutritive and biological values of the foodstuffs are saved and their organoleptic properties are improved. It is noted that in elaboration process of high-frequency pulse installations special consideration should be given to issues of the operating personnel safety discipline and securing conditions for the entire installation uninterrupted performance. With this objective in view the necessary requirements should be fulfilled on shielding the high- and low-voltage installation parts against high-frequency electromagnetic emissions registered by special differential sensors. Simultaneously, the abatement measures should be applied on the high-voltage equipment operational noise level. The authors offer a technique for noise abatement to admissible levels (lower than 80 dB A by means of coating the inside surface with shielded enclosure of densely-packed abutting sheets of porous electro-acoustic insulating

  4. High impedance fault detection in low voltage networks

    Energy Technology Data Exchange (ETDEWEB)

    Christie, R.D. (Univ. of Washington, Seattle, WA (United States). Dept. of Electrical Engineering); Zadehgol, H.; Habib, M.M. (Seattle City Light, WA (United States))

    1993-10-01

    High impedance faults are those with fault current magnitude similar to load currents. Experimental results were obtained that conform operating experience that such faults can occur in the low voltage (600V and below) underground distribution networks typically found in urban power systems. These faults produce current waveforms qualitatively similar to those found on overhead feeders, but quantitatively smaller. Loose connectors can produce similar, but cleaner current characteristics. Noisy loads remain a major impediment to reliable detection. Design and installation of an inexpensive prototype fault detector on the Seattle City Light street network is described.

  5. Self-monitoring high voltage transmission line suspension insulator

    Science.gov (United States)

    Stemler, Gary E.; Scott, Donald N.

    1981-01-01

    A high voltage transmission line suspension insulator (18 or 22) which monitors its own dielectric integrity. A dielectric rod (10) has one larger diameter end fitting attachable to a transmission line and another larger diameter end fitting attachable to a support tower. The rod is enclosed in a dielectric tube (14) which is hermetically sealed to the rod's end fittings such that a liquidtight space (20) is formed between the rod and the tube. A pressurized dielectric liquid is placed within that space. A discoloring dye placed within this space is used to detect the loss of the pressurized liquid.

  6. A Conservation Voltage Reduction Scheme for a Distribution Systems with Intermittent Distributed Generators

    Directory of Open Access Journals (Sweden)

    Pyeong-Ik Hwang

    2016-08-01

    Full Text Available In this paper, a conservation voltage reduction (CVR scheme is proposed for a distribution system with intermittent distributed generators (DGs, such as photovoltaics and wind turbines. The CVR is a scheme designed to reduce energy consumption by lowering the voltages supplied to customers. Therefore, an unexpected under-voltage violation can occur due to the variation of active power output from the intermittent DGs. In order to prevent the under-voltage violation and improve the CVR effect, a new reactive power controller which complies with the IEEE Std. 1547TM, and a parameter determination method for the controller are proposed. In addition, an optimal power flow (OPF problem to determine references for the resources of CVR is formulated with consideration of the intermittent DGs. The proposed method is validated using a modified IEEE 123-node test feeder. With the proposed method, the voltages of the test system are maintained to be greater than the lower bound, even though the active power outputs of the DGs are varied. Moreover, the CVR effect is improved compared to that used with the conventional reactive power control methods.

  7. 30 CFR 77.704-1 - Work on high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Work on high-voltage lines. 77.704-1 Section 77... MINES Grounding § 77.704-1 Work on high-voltage lines. (a) No high-voltage line shall be regarded as... provided in § 77.103) that such high-voltage line has been deenergized and grounded. Such qualified person...

  8. An accurate continuous calibration system for high voltage current transformer.

    Science.gov (United States)

    Tong, Yue; Li, Bin Hong

    2011-02-01

    A continuous calibration system for high voltage current transformers is presented in this paper. The sensor of this system is based on a kind of electronic instrument current transformer, which is a clamp-shape air core coil. This system uses an optical fiber transmission system for its signal transmission and power supply. Finally the digital integrator and fourth-order convolution window algorithm as error calculation methods are realized by the virtual instrument with a personal computer. It is found that this system can calibrate a high voltage current transformer while energized, which means avoiding a long calibrating period in the power system and the loss of power metering expense. At the same time, it has a wide dynamic range and frequency band, and it can achieve a high accuracy measurement in a complex electromagnetic field environment. The experimental results and the on-site operation results presented in the last part of the paper, prove that it can reach the 0.05 accuracy class and is easy to operate on site.

  9. Low power, high voltage power supply with fast rise/fall time

    Science.gov (United States)

    Bearden, Douglas B. (Inventor)

    2007-01-01

    A low power, high voltage power supply system includes a high voltage power supply stage and a preregulator for programming the power supply stage so as to produce an output voltage which is a predetermined fraction of a desired voltage level. The power supply stage includes a high voltage, voltage doubler stage connected to receive the output voltage from the preregulator and for, when activated, providing amplification of the output voltage to the desired voltage level. A first feedback loop is connected between the output of the preregulator and an input of the preregulator while a second feedback loop is connected between the output of the power supply stage and the input of the preregulator.

  10. High-Voltage, High-Impedance Ion Beam Production

    Science.gov (United States)

    2009-06-01

    collaboration with Tim Renk and Victor Harper- Slaboszewicz of Sandia National Laboratories. Joint experiments on Mercury are planned for the future...Young, "Pinched-Beam Ion Diode Scaling on the Aurora Pulser," J. Appl. Phys. 53, 8543 (1982). [8] T. J. Renk , et al., "Generation of Ion Beams in

  11. A New High Frequency Injection Method Based on Duty Cycle Shifting without Maximum Voltage Magnitude Loss

    DEFF Research Database (Denmark)

    Wang, Dong; Lu, Kaiyuan; Rasmussen, Peter Omand

    2015-01-01

    The conventional high frequency signal injection method is to superimpose a high frequency voltage signal to the commanded stator voltage before space vector modulation. Therefore, the magnitude of the voltage used for machine torque production is limited. In this paper, a new high frequency...

  12. 76 FR 19698 - Safety Zone; Repair of High Voltage Transmission Lines to Logan International Airport, Saugus...

    Science.gov (United States)

    2011-04-08

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone; Repair of High Voltage Transmission Lines..., within the Captain of the Port (COTP) Boston Zone to allow for repair of high voltage transmission lines... during the repair of high voltage transmission lines. Entering into, transiting through, mooring or...

  13. 76 FR 4575 - Safety Zone; Repair of High Voltage Transmission Lines to Logan International Airport, Saugus...

    Science.gov (United States)

    2011-01-26

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AAOO Safety Zone; Repair of High Voltage Transmission Lines... of high voltage transmission lines to Logan Airport. This safety zone is required to provide for the safety of life on navigable waters during the repair of high voltage transmission lines. Entering into...

  14. 30 CFR 75.705-10 - Tying into energized high-voltage surface circuits.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tying into energized high-voltage surface....705-10 Tying into energized high-voltage surface circuits. If the work of forming an additional circuit by tying into an energized high-voltage surface line is performed from the ground, any person...

  15. 30 CFR 75.811 - High-voltage underground equipment; grounding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage underground equipment; grounding... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.811 High-voltage underground equipment; grounding. Frames, supporting structures and...

  16. 30 CFR 77.807-3 - Movement of equipment; minimum distance from high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... high-voltage lines. 77.807-3 Section 77.807-3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.807-3 Movement of equipment; minimum distance from high-voltage lines. When any part of any equipment operated on the surface of any...

  17. 30 CFR 77.704-10 - Tying into energized high-voltage surface circuits.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tying into energized high-voltage surface... AREAS OF UNDERGROUND COAL MINES Grounding § 77.704-10 Tying into energized high-voltage surface circuits. If the work of forming an additional circuit by tying into an energized high-voltage surface line is...

  18. 30 CFR 75.705-1 - Work on high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Work on high-voltage lines. 75.705-1 Section 75... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.705-1 Work on high-voltage lines. (a) Section 75.705 specifically prohibits work on energized high-voltage lines underground; (b...

  19. Process engineering of high voltage alginate encapsulation of mesenchymal stem cells.

    Science.gov (United States)

    Gryshkov, Oleksandr; Pogozhykh, Denys; Zernetsch, Holger; Hofmann, Nicola; Mueller, Thomas; Glasmacher, Birgit

    2014-03-01

    Encapsulation of stem cells in alginate beads is promising as a sophisticated drug delivery system in treatment of a wide range of acute and chronic diseases. However, common use of air flow encapsulation of cells in alginate beads fails to produce beads with narrow size distribution, intact spherical structure and controllable sizes that can be scaled up. Here we show that high voltage encapsulation (≥ 15 kV) can be used to reproducibly generate spherical alginate beads (200-400 μm) with narrow size distribution (± 5-7%) in a controlled manner under optimized process parameters. Flow rate of alginate solution ranged from 0.5 to 10 ml/h allowed producing alginate beads with a size of 320 and 350 μm respectively, suggesting that this approach can be scaled up. Moreover, we found that applied voltages (15-25 kV) did not alter the viability and proliferation of encapsulated mesenchymal stem cells post-encapsulation and cryopreservation as compared to air flow. We are the first who employed a comparative analysis of electro-spraying and air flow encapsulation to study the effect of high voltage on alginate encapsulated cells. This report provides background in application of high voltage to encapsulate living cells for further medical purposes. Long-term comparison and work on alginate-cell interaction within these structures will be forthcoming. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. A high-voltage rechargeable magnesium-sodium hybrid battery

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yifei; An, Qinyou; Cheng, Yingwen; Liang, Yanliang; Ren, Yang; Sun, Cheng-Jun; Dong, Hui; Tang, Zhongjia; Li, Guosheng; Yao, Yan

    2017-04-01

    Growing global demand of safe and low-cost energy storage technology triggers strong interests in novel battery concepts beyond state-of-art Li-ion batteries. Here we report a high-voltage rechargeable Mg–Na hybrid battery featuring dendrite-free deposition of Mg anode and Na-intercalation cathode as a low-cost and safe alternative to Li-ion batteries for large-scale energy storage. A prototype device using a Na3V2(PO4)3 cathode, a Mg anode, and a Mg–Na dual salt electrolyte exhibits the highest voltage (2.60 V vs. Mg) and best rate performance (86% capacity retention at 10C rate) among reported hybrid batteries. Synchrotron radiation-based X-ray absorption near edge structure (XANES), atomic-pair distribution function (PDF), and high-resolution X-ray diffraction (HRXRD) studies reveal the chemical environment and structural change of Na3V2(PO4)3 cathode during the Na ion insertion/deinsertion process. XANES study shows a clear reversible shift of vanadium K-edge and HRXRD and PDF studies reveal a reversible two-phase transformation and V–O bond length change during cycling. The energy density of the hybrid cell could be further improved by developing electrolytes with a higher salt concentration and wider electrochemical window. This work represents a significant step forward for practical safe and low-cost hybrid batteries.

  1. Pollution Maintenance Techniques in Coastal High Voltage Installations

    Directory of Open Access Journals (Sweden)

    E. Pyrgioti

    2011-02-01

    Full Text Available Pollution of outdoor high voltage insulators is a common problem for utilities, with a considerable impact to power system reliability. In an effort to prevent possible flashovers due to pollution, many methods have been applied, aiming to improve the insulation performance, either by suppressing the formation of surface conductivity or by increasing the possible insulation level. In the case of substations, the selection of the appropriate technique is complex due to certain issues correlated to the nature of the installation. In this paper, several techniques usually implemented by utilities, are investigated based on the experienced gained in the case of Crete, a Greek island in southern Europe, where due to the coastal development of the power system, the majority of high voltage installations are exposed to intense marine pollution. The technique of coating insulators with Room Temperature Vulcanized Silicone Rubber (RTV SIR has proved rather efficient and therefore is presented extendedly. Correlation of the material behaviour with environmental conditions is discussed and results from long term monitoring, including environmental parameters and leakage current measurements, in a 150 kV Substation are presented. It is shown that RTV SIR coatings have remarkably suppressed surface activity and that porcelain insulators exhibit different activity period when coated.

  2. High-Speed Fuses in IGBT based Voltage Source Converters

    DEFF Research Database (Denmark)

    Iov, Florin; Blaabjerg, Frede; Rasmussen, Henrik

    2005-01-01

    The demand for protection of power electronic applications has during the last couple of years increased regarding the high-power IGBT modules. Even with an active protection, a high power IGBT still has a risk of exhibiting a violent rupture in the case of a fault if IGBT fuses do not protect it....... By introducing fuses into voltage source converters a better protection of IGBTs can be achieved. This paper is a complete overview of a research project carried out in cooperation by Aalborg University, Denmark and Cooper Bussmann International. This paper discusses three main issues regarding the IGBT fuse...... protection. First, the problem of adding inductance in the DC-link circuit is treated, second a short discussion of the protection of the IGBT module is done, and finally, the impact of the high frequency loading on the current carrying capability of the fuses is presented....

  3. Dynamic Stability Improvement of Grid Connected DFIG Using Enhanced Field Oriented Control Technique for High Voltage Ride Through

    OpenAIRE

    Ananth Duggirala, V.N.; Nagesh Kumar Gundavarapu, V.

    2015-01-01

    Doubly fed induction generator (DFIG) is a better alternative to increased power demand. Modern grid regulations force DFIG to operate without losing synchronism during overvoltages called high voltage ride through (HVRT) during grid faults. Enhanced field oriented control technique (EFOC) was proposed in Rotor Side Control of DFIG converter to improve power flow transfer and to improve dynamic and transient stability. Further electromagnetic oscillations are damped, improved voltage mitigati...

  4. 30 CFR 77.704-2 - Repairs to energized high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Repairs to energized high-voltage lines. 77.704... UNDERGROUND COAL MINES Grounding § 77.704-2 Repairs to energized high-voltage lines. An energized high-voltage... repairs will be performed on power circuits with a phase-to-phase nominal voltage no greater than 15,000...

  5. A VOLTAGE STABILIZER FOR A MICROGRID SYSTEM WITH TWO TYPES OF DISTRIBUTED GENERATION RESOURCES

    Directory of Open Access Journals (Sweden)

    Maedeh Mahzarnia

    2013-11-01

    Full Text Available ABSTRACT: Microgrids are used as controllable units connected to power grid, in which the electrical distances between reactive power sources and the loads that need the reactive compensation are not too much. Thus, a coordinated compensation of reactive sources has to be implemented in order to avoid a fast voltage collapse by proposing a Microgrid Voltage Stabilizer (MGVS. This stabilizer is desirable to improve the dynamic voltage profile and is tested at a 21-bus IEEE microgrid system. In order to verify the performance of this stabilizer, three distributed generation (DG resources are utilized in this microgrid (Two PV resources which are categorized as power-electronic converter based on DG and a diesel generator which is known as synchronous machine-based on DG. At first, the mentioned resources and all of their needed equipments are modeled. Then a control model of the stabilizer with appropriate parameters for the proposed microgrid is presented. Voltage deficiency of the system is the input of the stabilizer, and the output signal of the stabilizer, is divided between the DGs in order to provide required reactive power. The dynamic voltage profile of buses in the presence of MGVS and its absence has been compared by implying disturbances. Simulation results in MATLAB/SIMULINK show that the dynamic voltage profile of the buses improves satisfactorily with the addition of MGVS. ABSTRAK: Grid mikro digunakan sebagai unit kawalan yang disambungkan kepada grid kuasa, di mana jarak elektrikal antara sumber kuasa reaktif dan bebanan yang memerlukan kompensasi reaktif tidak terlalu besar.  Dengan itu, kompensasi yang selaras dengan sumber reaktif perlu diimplimentasikan untuk mengelak kegagalan voltan pantas dengan menggunakan Grid Mikro Penstabil Voltan (Microgrid Voltage Stabilizer - MGVS. Penstabil ini sesuai digunakan untuk meningkatkan profil voltan dinamik dan telah diuji ke atas sistem mikro grid 21-bus IEEE. Untuk memastikan

  6. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Marzocchi, Badder

    2017-01-01

    The CMS Electromagnetic Calorimeter is made of scintillating lead tungstate crystals, using avalanche photodiodes (APD) as photo-detectors in the barrel part. The high voltage system, consisting of 1224 channels, biases groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  7. Parallel input parallel output high voltage bi-directional converters for driving dielectric electro active polymer actuators

    DEFF Research Database (Denmark)

    Thummala, Prasanth; Zhang, Zhe; Andersen, Michael A. E.

    2014-01-01

    Dielectric electroactive polymer (DEAP) actuators are capacitive devices which provide mechanical motions when charged electrically. The charging characteristics of a DEAP actuator depends on its size, voltage applied to its electrodes, and its operating frequency. The main idea of this paper....... This enables operating the DEAP actuators in various static and dynamic applications e.g. positioning, vibration generation or damping, and pumps. The proposed idea is experimentally verified by connecting three high voltage converters in parallel to operate a single DEAP actuator. The experimental results...... with both film capacitive load and the DEAP actuator are shown for a maximum charging voltage of 2 kV....

  8. High-voltage atmospheric breakdown across intervening rutile dielectrics.

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, Kenneth Martin; Simpson, Sean; Coats, Rebecca Sue; Jorgenson, Roy Eberhardt; Hjalmarson, Harold Paul; Pasik, Michael Francis

    2013-09-01

    This report documents work conducted in FY13 on electrical discharge experiments performed to develop predictive computational models of the fundamental processes of surface breakdown in the vicinity of high-permittivity material interfaces. Further, experiments were conducted to determine if free carrier electrons could be excited into the conduction band thus lowering the effective breakdown voltage when UV photons (4.66 eV) from a high energy pulsed laser were incident on the rutile sample. This report documents the numerical approach, the experimental setup, and summarizes the data and simulations. Lastly, it describes the path forward and challenges that must be overcome in order to improve future experiments for characterizing the breakdown behavior for rutile.

  9. Unique Power Dense, Configurable, Robust, High-Voltage Power Supplies Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Princeton Power will develop and deliver three small, lightweight 50 W high-voltage power supplies that have a configurable output voltage range from 500 to 50 kVDC....

  10. Stepwise compensation waveform generation by using Josephson voltage standards for joule balance

    Science.gov (United States)

    Wang, Gang; Xu, Jinxin; You, Qiang; Li, Zhengkun; Zhang, Zhonghua

    2017-01-01

    Flux linkage difference in the new joule balance can be obtained by the time integration of the induced voltage u(t) from the suspended coil relative to a moving magnet driven by a dc motor translation platform. Due to the finite acceleration of the dc motor, the transition and waveform of u(t) are finite and not regular. To accurately measure the time integration of u(t), a compensation waveform with precision time integration should be synthesized. In this paper, a stepwise compensation waveform is synthesized by a programmable Josephson voltage standard (PJVS) according to u(t). The accuracy of measuring the stepwise waveform with multiple transitions can be improved by reducing the ratio of the time integrated value of the total transitions to the total waveform less than one part in 102 in the joule balance. The time integration of the rise/fall transition is measured by a synchronized reference square wave generated by another PJVS system. With the total time integration more than 20 Vs, the uncertainty of the generated stepwise waveform is within 5.2  ×  10-8 VsV-1s-1. The result confirms that the PJVS has the capability to generate a stepwise compensation voltage for flux linkage difference measurement.

  11. 75 FR 17529 - High-Voltage Continuous Mining Machine Standard for Underground Coal Mines

    Science.gov (United States)

    2010-04-06

    ... condition occurs. Ungrounded circuits include high-voltage transformers that power low- and medium-voltage... transformers in the power center. This will provide a safe means of de-energizing high-voltage circuits in the... machines in underground coal mines. It also revises MSHA's design requirements for approval of these mining...

  12. Battery powered high output voltage bidirectional flyback converter for cylindrical DEAP actuator

    DEFF Research Database (Denmark)

    Huang, Lina; Thummala, Prasanth; Zhang, Zhe

    2012-01-01

    DEAP (Dielectric Electro Active Polymer) actuator is essentially a capacitive load and can be applied in various actuation occasions. However, high voltage is needed to actuate it. In this paper, a high voltage bidirectional flyback converter with low input voltage is presented. The fundamental...

  13. On-load Tap Changer Diagnosis on High-Voltage Power Transformers using Dynamic Resistance Measurements

    NARCIS (Netherlands)

    Erbrink, J.J.

    2011-01-01

    High-voltage transformers have tap changers to regulate the voltage in the high-voltage network when the load changes. Those tap changers are subject to different degradation mechanisms and need regular maintenance. Various defects, like contact degradation, often remain undetected and the

  14. 30 CFR 57.12071 - Movement or operation of equipment near high-voltage powerlines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Movement or operation of equipment near high-voltage powerlines. 57.12071 Section 57.12071 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION...-voltage powerlines. When equipment must be moved or operated near energized high-voltage powerlines (other...

  15. 30 CFR 77.807-2 - Booms and masts; minimum distance from high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ...-voltage lines. 77.807-2 Section 77.807-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.807-2 Booms and masts; minimum distance from high-voltage lines. The booms and masts of equipment operated on the surface of any...

  16. 30 CFR 56.12071 - Movement or operation of equipment near high-voltage power lines.

    Science.gov (United States)

    2010-07-01

    ...-voltage power lines. 56.12071 Section 56.12071 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... NONMETAL MINES Electricity § 56.12071 Movement or operation of equipment near high-voltage power lines. When equipment must be moved or operated near energized high-voltage powerlines (other than trolley...

  17. A Fiber-Optic Sensor for Acoustic Emission Detection in a High Voltage Cable System

    Directory of Open Access Journals (Sweden)

    Tongzhi Zhang

    2016-11-01

    Full Text Available We have proposed and demonstrated a Michelson interferometer-based fiber sensor for detecting acoustic emission generated from the partial discharge (PD of the accessories of a high-voltage cable system. The developed sensor head is integrated with a compact and relatively high sensitivity cylindrical elastomer. Such a sensor has a broadband frequency response and a relatively high sensitivity in a harsh environment under a high-voltage electric field. The design and fabrication of the sensor head integrated with the cylindrical elastomer is described, and a series of experiments was conducted to evaluate the sensing performance. The experimental results demonstrate that the sensitivity of our developed sensor for acoustic detection of partial discharges is 1.7 rad / ( m ⋅ Pa . A high frequency response up to 150 kHz is achieved. Moreover, the relatively high sensitivity for the detection of PD is verified in both the laboratory environment and gas insulated switchgear. The obtained results show the great potential application of a Michelson interferometer-based fiber sensor integrated with a cylindrical elastomer for in-situ monitoring high-voltage cable accessories for safety work.

  18. A Fiber-Optic Sensor for Acoustic Emission Detection in a High Voltage Cable System

    Science.gov (United States)

    Zhang, Tongzhi; Pang, Fufei; Liu, Huanhuan; Cheng, Jiajing; Lv, Longbao; Zhang, Xiaobei; Chen, Na; Wang, Tingyun

    2016-01-01

    We have proposed and demonstrated a Michelson interferometer-based fiber sensor for detecting acoustic emission generated from the partial discharge (PD) of the accessories of a high-voltage cable system. The developed sensor head is integrated with a compact and relatively high sensitivity cylindrical elastomer. Such a sensor has a broadband frequency response and a relatively high sensitivity in a harsh environment under a high-voltage electric field. The design and fabrication of the sensor head integrated with the cylindrical elastomer is described, and a series of experiments was conducted to evaluate the sensing performance. The experimental results demonstrate that the sensitivity of our developed sensor for acoustic detection of partial discharges is 1.7 rad/(m⋅Pa). A high frequency response up to 150 kHz is achieved. Moreover, the relatively high sensitivity for the detection of PD is verified in both the laboratory environment and gas insulated switchgear. The obtained results show the great potential application of a Michelson interferometer-based fiber sensor integrated with a cylindrical elastomer for in-situ monitoring high-voltage cable accessories for safety work. PMID:27916900

  19. Design and power management of an offshore medium voltage DC microgrid realized through high voltage power electronics technologies and control

    Science.gov (United States)

    Grainger, Brandon Michael

    The growth in the electric power industry's portfolio of Direct Current (DC) based generation and loads have captured the attention of many leading research institutions. Opportunities for using DC based systems have been explored in electric ship design and have been a proven, reliable solution for transmitting bulk power onshore and offshore. To integrate many of the renewable resources into our existing AC grid, a number of power conversions through power electronics are required to condition the equipment for direct connection. Within the power conversion stages, there is always a requirement to convert to or from DC. The AC microgrid is a conceptual solution proposed for integrating various types of renewable generation resources. The fundamental microgrid requirements include the capability of operating in islanding mode and/or grid connected modes. The technical challenges associated with microgrids include (1) operation modes and transitions that comply with IEEE1547 without extensive custom engineering and (2) control architecture and communication. The Medium Voltage DC (MVDC) architecture, explored by the University of Pittsburgh, can be visualized as a special type of DC microgrid. This dissertation is multi-faceted, focused on many design aspects of an offshore DC microgrid. The focal points of the discussion are focused on optimized high power, high frequency magnetic material performance in electric machines, transformers, and DC/DC power converters---all components found within offshore, power system architectures. A new controller design based upon model reference control is proposed and shown to stabilize the electric motor drives (modeled as constant power loads), which serve as the largest power consuming entities in the microgrid. The design and simulation of a state-of-the-art multilevel converter for High Voltage DC (HVDC) is discussed and a component sensitivity analysis on fault current peaks is explored. A power management routine is

  20. Spatial and temporal instabilities in high voltage power devices

    Energy Technology Data Exchange (ETDEWEB)

    Milady, Saeed

    2010-01-29

    Dynamic avalanche can occur during the turn-off process of high voltage bipolar devices, e.g. IGBTs and p{sup +}n{sup -}n{sup +} power diodes, that may result in spatial instabilities of the homogeneous current density distribution across the device and the formation of current filaments. Filaments may cause the destruction of the device, mainly because of the high local temperatures. The first part of this work is dedicated to the current filament behavior. The positive feedback mechanisms caused by the transient current flow through the gate capacitance of an IGBT operating under short circuit conditions may result in oscillations and temporal instabilities of the IGBT current. The oscillations may cause electromagnetic interference (EMI). Furthermore, the positive feedback mechanism may accelerate the over-heating of the device and result in a thermal run-away. This is the subject of the second part of this work. In the first part of this work using the device simulation results of power diodes the underlying physical mechanisms of the filament dynamic is investigated. Simulation results of diode structures with evenly distributed doping inhomogeneities show that, the filament motion gets smoother as the distance between the inhomogeneities decreases. Hopping to faraway inhomogeneities turns into the hopping to neighboring ones and finally a smooth motion. In homogeneous structures the slow inhibitory effect of the electron-hole plasma extraction and the fast activation, due to hole current flowing along the filament, result in a smooth filament motion. An analytical model for the filament velocity under isothermal conditions is presented that can reproduce the simulation data satisfactorily. The influence of the boundary conditions on the filament behavior is discussed. The positive beveled edge termination prohibits a long stay of the filament at the edge reducing the risk of filament pinning. Self-heating effects may turn the initially electrically triggered

  1. Laser ultrasonic analysis of normal modes generated by a voltage pulse on an AT quartz sensor.

    Science.gov (United States)

    Goossens, Jozefien; Martinez, Loïc; Glorieux, Christ; Wilkie-Chancellier, Nicolas; Ehssein, Chighali Ould; Serfaty, Stéphane

    2006-12-22

    Laser ultrasonic detection is a versatile and highly sensitive tool for the observation of surface waves. In the following study, laser ultrasonic detection is used for the experimental study of spurious normal vibration modes of a disk quartz sensor excited by a voltage pulse. The AT cut crystal (cut of the crystal relative to the the main crystallographic axis is 35.25 degrees) is optimal for generating mainly thickness-shear vibrations (central frequency 6 MHz) on the quartz surface. However, resulting from shear-to-longitudinal and shear-to-surface mode conversion, and from the weak coupling with the other crystallographic axes, other modes (thickness-compressional and bending modes) are always present in the plate response. Since the laser vibrometer is sensitive to normal displacements, the laser investigation shows waves that can be considered as unwanted for the AT quartz used as a shear sensor. The scanned three dimensional (3D) amplitude-space-time signals are carefully analysed using their representation in three dual Fourier domains (space-time, wave number-frequency). Results on the transient analysis of the waves, the normal bending modes and the dispersion curves are shown.

  2. Breakdown in helium in high-voltage open discharge with subnanosecond current front rise

    Energy Technology Data Exchange (ETDEWEB)

    Schweigert, I. V., E-mail: ischweig@itam.nsc.ru; Alexandrov, A. L. [Russian Academy of Sciences, Khristianovich Institute of Theoretical and Applied Mechanics, Siberian Branch (Russian Federation); Bokhan, P. A.; Zakrevskiy, Dm. E. [Russian Academy of Sciences, Rzhanov Institute of Semiconductors Physics, Siberian Branch (Russian Federation)

    2016-07-15

    Investigations of high-voltage open discharge in helium have shown a possibility of generation of current pulses with subnanosecond front rise, due to ultra-fast breakdown development. The open discharge is ignited between two planar cathodes with mesh anode in the middle between them. For gas pressure 6 Torr and 20 kV applied voltage, the rate of current rise reaches 500 A/(cm{sup 2} ns) for current density 200 A/cm{sup 2} and more. The time of breakdown development was measured for different helium pressures and a kinetic model of breakdown in open discharge is presented, based on elementary reactions for electrons, ions and fast atoms. The model also includes various cathode emission processes due to cathode bombardment by ions, fast atoms, electrons and photons of resonant radiation with Doppler shift of frequency. It is shown, that the dominating emission processes depend on the evolution of the discharge voltage during the breakdown. In the simulations, two cases of voltage behavior were considered: (i) the voltage is kept constant during the breakdown; (ii) the voltage is reduced with the growth of current. For the first case, the exponentially growing current is maintained due to photoemission by the resonant photons with Doppler-shifted frequency. For the second case, the dominating factor of current growth is the secondary electron emission. In both cases, the subnanosecond rise of discharge current was obtained. Also the effect of gas pressure on breakdown development was considered. It was found that for 20 Torr gas pressure the time of current rise decreases to 0.1 ns, which is in agreement with experimental data.

  3. Enhanced output voltage generation via ZnO nanowires (50 nm): Effect of diameter thinning on voltage enhancement

    Science.gov (United States)

    Ahmad, Mansoor; Iqbal, Muhammad Azhar; Kiely, Janice; Luxton, Richard; Jabeen, Musarrat

    2017-05-01

    50 nm ZnO nanowires were grown on indium tin oxide (ITO) coated poly ethylene terephthalate (PET) substrates by adapting facile aqueous growth technique using low temperature and vacuum conditions. Prior to growth of ZnO nanowires, pure hexagonal wurtzite structured seed layer was grown on flexible substrates. Surface morphology of nanostructure has been examined by scanning electron microscopy (SEM). Vertical growth orientation has been evidenced in XRD patterns. Minute external mechanical force ( 50 nN) has produced periodic voltage peaks. 2.5 nm and 7.5 nm thick sputtered Pt electrode have been tested to obtain output voltages. 50 nm ZnO nanowires has produced a maximum output voltage of 2.717 volts having an output power density of 397.1 mW/cm2. By squeezing the diameter, we have reduced reverse leakage current through nanowires and enhanced output voltage.

  4. WECS Based Self-Excited Squirrel-Cage Induction Generator with Reduced Voltage Source Inverter Rating

    Directory of Open Access Journals (Sweden)

    O.Chandra sekha

    2014-07-01

    Full Text Available This paper presents the regulation of the voltage and frequency of a stand-alone fixed-pitch wind energy conversion system (WECS based on a self-excited squirrel-cage induction machine. A shunt connected voltage source inverter (VSI and a controllable dump load are used for regulation purposes. A battery bank is included in the dc side of the VSI so that it can absorb and inject active power thus increasing the efficiency and availability of the system. A control scheme for the VSI with self-governing control of real and reactive power allows the state of charge of the batteries to be kept in a safe range while maximizing the voltage regulating capabilities of the VSI. The characteristics of the wind turbine, selfexcited generator, and the ratings of the VSI are considered in order to find out the load range for which voltage and frequency can be regulated for a given wind speed range. The possibility of the proposed system is verified by MATLAB/SIMULINK. simulations.

  5. An Improved Control Strategy of Limiting the DC-Link Voltage Fluctuation for a Doubly Fed Induction Wind Generator

    DEFF Research Database (Denmark)

    Yao, J.; Li, H.; Liao, Y.

    2008-01-01

    The paper presents to develop a new control strategy of limiting the dc-link voltage fluctuation for a back-to-back pulsewidth modulation converter in a doubly fed induction generator (DFIG) for wind turbine systems. The reasons of dc-link voltage fluctuation are analyzed. An improved control...... strategy with the instantaneous rotor power feedback is proposed to limit the fluctuation range of the dc-link voltage. An experimental rig is set up to valid the proposed strategy, and the dynamic performances of the DFIG are compared with the traditional control method under a constant grid voltage...... effective, and the fluctuation of the dc-link voltage may be successfully limited in a small range under a constant grid voltage and a non-serious grid voltage dip....

  6. Hybrid-PIC Modeling of a High-Voltage, High-Specific-Impulse Hall Thruster

    Science.gov (United States)

    Smith, Brandon D.; Boyd, Iain D.; Kamhawi, Hani; Huang, Wensheng

    2013-01-01

    The primary life-limiting mechanism of Hall thrusters is the sputter erosion of the discharge channel walls by high-energy propellant ions. Because of the difficulty involved in characterizing this erosion experimentally, many past efforts have focused on numerical modeling to predict erosion rates and thruster lifespan, but those analyses were limited to Hall thrusters operating in the 200-400V discharge voltage range. Thrusters operating at higher discharge voltages (V(sub d) >= 500 V) present an erosion environment that may differ greatly from that of the lower-voltage thrusters modeled in the past. In this work, HPHall, a well-established hybrid-PIC code, is used to simulate NASA's High-Voltage Hall Accelerator (HiVHAc) at discharge voltages of 300, 400, and 500V as a first step towards modeling the discharge channel erosion. It is found that the model accurately predicts the thruster performance at all operating conditions to within 6%. The model predicts a normalized plasma potential profile that is consistent between all three operating points, with the acceleration zone appearing in the same approximate location. The expected trend of increasing electron temperature with increasing discharge voltage is observed. An analysis of the discharge current oscillations shows that the model predicts oscillations that are much greater in amplitude than those measured experimentally at all operating points, suggesting that the differences in oscillation amplitude are not strongly associated with discharge voltage.

  7. Investigating Enhancement Mode Gallium Nitride Power FETs in High Voltage, High Frequency Soft Switching Converters

    DEFF Research Database (Denmark)

    Nour, Yasser; Knott, Arnold; Jørgensen, Ivan Harald Holger

    2016-01-01

    of using enhancement mode gallium nitride switches to form a 50V quasi-square-wave zero-voltage-switching buck converter running at 2-6 MHz under full load. The designed converter achieved 83% efficiency converting 50V input voltage to 12.2V at 9W load.......An increased attention has been detected to develop smaller and lighter high voltage power converters in the range of 50V to 400V domain. The main applications for these converters are mainly focused for Power over Ethernet (PoE), LED lighting and AC adapters. This work will discuss a study...

  8. Investigating Enhancement Mode Gallium Nitride Power FETs in High Voltage, High Frequency Soft Switching Converters

    DEFF Research Database (Denmark)

    Nour, Yasser; Knott, Arnold; Jørgensen, Ivan Harald Holger

    2016-01-01

    An increased attention has been detected to develop smaller and lighter high voltage power converters in the range of 50V to 400V domain. The main applications for these converters are mainly focused for Power over Ethernet (PoE), LED lighting and AC adapters. This work will discuss a study of us...... of using enhancement mode gallium nitride switches to form a 50V quasi-square-wave zero-voltage-switching buck converter running at 2-6 MHz under full load. The designed converter achieved 83% efficiency converting 50V input voltage to 12.2V at 9W load....

  9. Electric and magnetic field measurements in a high voltage center.

    Science.gov (United States)

    Safigianni, Anastasia S; Spyridopoulos, Anastasios I; Kanas, Vasilis L

    2012-01-01

    This paper investigates the electric and magnetic fields inside a large high voltage center constituted both of 400/150 and 150/20 kV substation areas. Results of previous field measurements and calculations in substations, made by the authors of this paper or other researchers, are presented first. The basic data distinguishing the examined center from previously examined substations follow. The main results of the field measurements in the areas of the above-mentioned center are presented in relevant diagrams. General conclusions arising from the comparison of the measured field values with relevant reference levels in force for safe public and occupational exposure as well as with the results of previous research are finally given.

  10. Growing of semiinsulating Si for high-voltage devices

    Directory of Open Access Journals (Sweden)

    Turtsevich A. S.

    2008-02-01

    Full Text Available The effect of the N2O/SiH4 flow ratio ( on the peculiarities of initial stages, structural, morphological and electrophysical properties of the SiPOS film has been investigates. The average roughness of thin SiPOS films (Ra is 0.09 nm (for polysilicon films - 1.52 nm. The films having 2.5-22.0 at.% oxygen have quasi-crystal structure. Explanation of the obtained results on the base of multi-route layer deposition process in SiH4-N2O gas system has been presented. The obtained results have been used for the optimization of SiPOS film deposition process under high-voltage device.

  11. Locational Pricing to Mitigate Voltage Problems Caused by High PV Penetration

    Directory of Open Access Journals (Sweden)

    Sam Weckx

    2015-05-01

    Full Text Available In this paper, a locational marginal pricing algorithm is proposed to control the voltage in unbalanced distribution grids. The increasing amount of photovoltaic (PV generation installed in the grid may cause the voltage to rise to unacceptable levels during periods of low consumption. With locational prices, the distribution system operator can steer the reactive power consumption and active power curtailment of PV panels to guarantee a safe network operation. Flexible loads also respond to these prices. A distributed gradient algorithm automatically defines the locational prices that avoid voltage problems. Using these locational prices results in a minimum cost for the distribution operator to control the voltage. Locational prices can differ between the three phases in unbalanced grids. This is caused by a higher consumption or production in one of the phases compared to the other phases and provides the opportunity for arbitrage, where power is transferred from a phase with a low price to a phase with a high price. The effect of arbitrage is analyzed. The proposed algorithm is applied to an existing three-phase four-wire radial grid. Several simulations with realistic data are performed.

  12. HYBRID EVOLUTIONARY ALGORITHMS FOR FREQUENCY AND VOLTAGE CONTROL IN POWER GENERATING SYSTEM

    Directory of Open Access Journals (Sweden)

    A. Soundarrajan

    2010-10-01

    Full Text Available Power generating system has the responsibility to ensure that adequate power is delivered to the load, both reliably and economically. Any electrical system must be maintained at the desired operating level characterized by nominal frequency and voltage profile. But the ability of the power system to track the load is limited due to physical and technical consideration. Hence, a Power System Control is required to maintain a continuous balance between power generation and load demand. The quality of power supply is affected due to continuous and random changes in load during the operation of the power system. Load Frequency Controller (LFC and Automatic Voltage Regulator (AVR play an important role in maintaining constant frequency and voltage in order to ensure the reliability of electric power. The fixed gain PID controllers used for this application fail to perform under varying load conditions and hence provide poor dynamic characteristics with large settling time, overshoot and oscillations. In this paper, Evolutionary Algorithms (EA like, Enhanced Particle Swarm Optimization (EPSO, Multi Objective Particle Swarm Optimization (MOPSO, and Stochastic Particle Swarm Optimization (SPSO are proposed to overcome the premature convergence problem in a standard PSO. These algorithms reduce transient oscillations and also increase the computational efficiency. Simulation results demonstrate that the proposed controller adapt themselves appropriate to varying loads and hence provide better performance characteristics with respect to settling time, oscillations and overshoot.

  13. Voltage Regulation Using a Permanent Magnet Synchronous Generator with a Series Compensator: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Ping; Wu, Ziping; Muljadi, Eduard; Gao, Wenzhong

    2015-08-24

    A wind power plant (WPP) is often operated at unity power factor, and the utility host where the WPP connects prefers to regulate the voltage. Although this may not be an issue in a stiff grid, the connection to a weak grid can be a problematic. This paper explores the advantages of having voltage regulation capability via reactive power control. Another issue in wind power generation is that not all turbines are able to control their reactive power due to technical reasons or contractual obligations. A synchronous condenser (SC) using a permanent magnet synchronous generator (PMSG) is proposed to provide necessary reactive power for regulating voltage at a weak grid connection. A PMSG has the advantage of higher efficiency and reliability. Because of its lack of a field winding, a PMSG is typically controlled by a full-power converter, which can be costly. In the proposed system, the reactive power of the SC is controlled by a serially connected compensator operating in a closed-loop configuration. The compensator also damps the PMSG’s tendency to oscillate. The compensator’s VA rating is only a fraction of the rating of the SC and the PMSG. In this initial investigation, the proposed scheme is shown to be effective by computer simulations.

  14. Evaluation of the piezoelectric properties and voltage generation of flexible zinc oxide thin films.

    Science.gov (United States)

    Laurenti, M; Stassi, S; Lorenzoni, M; Fontana, M; Canavese, G; Cauda, V; Pirri, C F

    2015-05-29

    Local piezoresponse and piezoelectric output voltage were evaluated on ZnO thin films deposited by radio-frequency magnetron sputtering on hard Si/Ti/Au and flexible Cu-coated polyimide substrates. Three different thicknesses of ZnO films were studied (285 nm, 710 nm, and 1380 nm), focusing on characteristics like crystallinity, grain size, surface roughness, and morphology. Independent of the nature of the metal layer and the substrate, our results show that thicker films presented a higher level of crystallinity and a preferential orientation along the c-axis direction, as well as a lower density of grain boundaries and larger crystal sizes. The improvement of the crystalline structure of the material directly enhances its piezoelectric properties, as confirmed by the local characterizations performed by piezoresponse force microscopy and by the evaluation of the output voltage generation under the application of a periodical mechanical deformation on the whole film. In particular, the highest value of the d33 coefficient obtained (8 pm V(-1)) and the highest generated output voltage (0.746 V) belong to the thickest films on hard and flexible substrates, respectively. These results envision the use of ZnO thin films--particularly on flexible substrates--as conformable, reliable, and efficient active materials for use in nanosensing, actuation, and piezoelectric nanogenerators.

  15. First high-voltage measurements using Ca+ ions at the ALIVE experiment

    Science.gov (United States)

    König, K.; Geppert, Ch.; Krämer, J.; Maaß, B.; Otten, E. W.; Ratajczyk, T.; Nörtershäuser, W.

    2017-11-01

    Many physics experiments depend on accurate high-voltage measurements to determine for example the exact retardation potential of an electron spectrometer as in the KATRIN experiment or the acceleration voltage of the ions at ISOL facilities. Until now only precision high-voltage dividers can be used to measure voltages up to 65 kV with an accuracy of 1 ppm. However, these dividers need frequent calibration and cross-checking and the direct traceability is not given. In this article we will describe the status of an experiment which aims to measure high voltages using collinear laser spectroscopy and which has the potential to provide a high-voltage standard and hence, a calibration source for precision high-voltage dividers on the 1 ppm level.

  16. First high-voltage measurements using Ca{sup +} ions at the ALIVE experiment

    Energy Technology Data Exchange (ETDEWEB)

    König, K., E-mail: kkoenig@ikp.tu-darmstadt.de [Technische Universität Darmstadt, Institut für Kernphysik (Germany); Geppert, Ch. [Universität Mainz, Institut für Kernchemie (Germany); Krämer, J.; Maaß, B. [Technische Universität Darmstadt, Institut für Kernphysik (Germany); Otten, E. W. [Universität Mainz, Institut für Physik (Germany); Ratajczyk, T.; Nörtershäuser, W. [Technische Universität Darmstadt, Institut für Kernphysik (Germany)

    2017-11-15

    Many physics experiments depend on accurate high-voltage measurements to determine for example the exact retardation potential of an electron spectrometer as in the KATRIN experiment or the acceleration voltage of the ions at ISOL facilities. Until now only precision high-voltage dividers can be used to measure voltages up to 65 kV with an accuracy of 1 ppm. However, these dividers need frequent calibration and cross-checking and the direct traceability is not given. In this article we will describe the status of an experiment which aims to measure high voltages using collinear laser spectroscopy and which has the potential to provide a high-voltage standard and hence, a calibration source for precision high-voltage dividers on the 1 ppm level.

  17. Passivity-Based Control of a Doubly Fed Induction Generator System under Unbalanced Grid Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Jiawei Huang

    2017-08-01

    Full Text Available According to the theory of passivity-based control (PBC, this paper establishes a port-controlled Hamiltonian system with dissipation (PCHD model for a doubly fed induction generator (DFIG system under unbalanced grid voltage conditions and proposes a method of interconnection and damping assignment passivity-based control (IDA-PBC of the system under such conditions. By using this method, the rotor-side converter and grid-side converter can be controlled simultaneously in order to improve fault ride-through capability of the DFIG system. Simulation results indicate that this IDA-PBC strategy effectively suppresses fluctuations of output current and power in the DFIG system during unbalanced grid voltage sag/swell, enhances dynamic performance, and improves the robustness of the system.

  18. High voltage and high specific capacity dual intercalating electrode Li-ion batteries

    Science.gov (United States)

    West, William C. (Inventor); Blanco, Mario (Inventor)

    2010-01-01

    The present invention provides high capacity and high voltage Li-ion batteries that have a carbonaceous cathode and a nonaqueous electrolyte solution comprising LiF salt and an anion receptor that binds the fluoride ion. The batteries can comprise dual intercalating electrode Li ion batteries. Methods of the present invention use a cathode and electrode pair, wherein each of the electrodes reversibly intercalate ions provided by a LiF salt to make a high voltage and high specific capacity dual intercalating electrode Li-ion battery. The present methods and systems provide high-capacity batteries particularly useful in powering devices where minimizing battery mass is important.

  19. The progress of funnelling gun high voltage condition and beam test

    Energy Technology Data Exchange (ETDEWEB)

    Wang, E. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ben-Zvi, I. [Brookhaven National Lab. (BNL), Upton, NY (United States); Gassner, D. M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Lambiase, R. [Brookhaven National Lab. (BNL), Upton, NY (United States); Meng, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Rahman, O. [Brookhaven National Lab. (BNL), Upton, NY (United States); Pikin, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Rao, T. [Brookhaven National Lab. (BNL), Upton, NY (United States); Sheehy, B. [Brookhaven National Lab. (BNL), Upton, NY (United States); Skaritka, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Pietz, J. [Transfer Engineering and Manufacturing, Inc., Fremont, CA (United States); Ackeret, M. [Transfer Engineering and Manufacturing, Inc., Fremont, CA (United States); Yeckel, C. [Thompson, Stangenes Industries, Palo Alto, CA (United States); Miller, R. [Thompson, Stangenes Industries, Palo Alto, CA (United States); Dobrin, E. [Thompson, Stangenes Industries, Palo Alto, CA (United States); Thompson, K. [Thompson, Stangenes Industries, Palo Alto, CA (United States)

    2015-05-03

    A prototype of a high average current polarized electron funneling gun as an eRHIC injector has been built at BNL. The gun was assembled and tested at Stangenes Incorporated. Two beams were generated from two GaAs photocathodes and combined by a switched combiner field. We observed the combined beams on a YAG crystal and measured the photocurrent by a Faraday cup. The gun has been shipped to Stony Brook University and is being tested there. In this paper we will describe the major components of the gun and recent beam test results. High voltage conditioning is discussed as well.

  20. High-Voltage-Input Level Translator Using Standard CMOS

    Science.gov (United States)

    Yager, Jeremy A.; Mojarradi, Mohammad M.; Vo, Tuan A.; Blalock, Benjamin J.

    2011-01-01

    proposed integrated circuit would translate (1) a pair of input signals having a low differential potential and a possibly high common-mode potential into (2) a pair of output signals having the same low differential potential and a low common-mode potential. As used here, "low" and "high" refer to potentials that are, respectively, below or above the nominal supply potential (3.3 V) at which standard complementary metal oxide/semiconductor (CMOS) integrated circuits are designed to operate. The input common-mode potential could lie between 0 and 10 V; the output common-mode potential would be 2 V. This translation would make it possible to process the pair of signals by use of standard 3.3-V CMOS analog and/or mixed-signal (analog and digital) circuitry on the same integrated-circuit chip. A schematic of the circuit is shown in the figure. Standard 3.3-V CMOS circuitry cannot withstand input potentials greater than about 4 V. However, there are many applications that involve low-differential-potential, high-common-mode-potential input signal pairs and in which standard 3.3-V CMOS circuitry, which is relatively inexpensive, would be the most appropriate circuitry for performing other functions on the integrated-circuit chip that handles the high-potential input signals. Thus, there is a need to combine high-voltage input circuitry with standard low-voltage CMOS circuitry on the same integrated-circuit chip. The proposed circuit would satisfy this need. In the proposed circuit, the input signals would be coupled into both a level-shifting pair and a common-mode-sensing pair of CMOS transistors. The output of the level-shifting pair would be fed as input to a differential pair of transistors. The resulting differential current output would pass through six standoff transistors to be mirrored into an output branch by four heterojunction bipolar transistors. The mirrored differential current would be converted back to potential by a pair of diode-connected transistors

  1. Low Voltage Ride-through in DFIG Wind Generators by Controlling the Rotor Current without Crowbars

    Directory of Open Access Journals (Sweden)

    Jaime Rodríguez Arribas

    2014-01-01

    Full Text Available Among all the different types of electric wind generators, those that are based on doubly fed induction generators, or DFIG technology, are the most vulnerable to grid faults such as voltage sags. This paper proposes a new control strategy for this type of wind generator, that allows these devices to withstand the effects of a voltage sag while following the new requirements imposed by grid operators. This new control strategy makes the use of complementary devices such as crowbars unnecessary, as it greatly reduces the value of currents originated by the fault. This ensures less costly designs for the rotor systems as well as a more economic sizing of the necessary power electronics. The strategy described here uses an electric generator model based on space-phasor theory that provides a direct control over the position of the rotor magnetic flux. Controlling the rotor magnetic flux has a direct influence on the rest of the electrical variables enabling the machine to evolve to a desired work point during the transient imposed by the grid disturbance. Simulation studies have been carried out, as well as test bench trials, in order to prove the viability and functionality of the proposed control strategy.

  2. Advances in high voltage insulation and arc interruption in SF6 and vacuum

    CERN Document Server

    Maller, V N

    1982-01-01

    Advances in High Voltage Insulation and Arc Interruption in SF6 and Vacuum deals with high voltage breakdown and arc extinction in sulfur hexafluoride (SF6) and high vacuum, with special emphasis on the application of these insulating media in high voltage power apparatus and devices. The design and developmental aspects of various high voltage power apparatus using SF6 and high vacuum are highlighted. This book is comprised of eight chapters and opens with a discussion on electrical discharges in SF6 and high vacuum, along with the properties and handling of SF6 gas. The following chapters fo

  3. Voltage-gated sodium channel expression and action potential generation in differentiated NG108-15 cells.

    Science.gov (United States)

    Liu, Jinxu; Tu, Huiyin; Zhang, Dongze; Zheng, Hong; Li, Yu-Long

    2012-10-25

    The generation of action potential is required for stimulus-evoked neurotransmitter release in most neurons. Although various voltage-gated ion channels are involved in action potential production, the initiation of the action potential is mainly mediated by voltage-gated Na+ channels. In the present study, differentiation-induced changes of mRNA and protein expression of Na+ channels, Na+ currents, and cell membrane excitability were investigated in NG108-15 cells. Whole-cell patch-clamp results showed that differentiation (9 days) didn't change cell membrane excitability, compared to undifferentiated state. But differentiation (21 days) induced the action potential generation in 45.5% of NG108-15 cells (25/55 cells). In 9-day-differentiated cells, Na+ currents were mildly increased, which was also found in 21-day differentiated cells without action potential. In 21-day differentiated cells with action potential, Na+ currents were significantly enhanced. Western blot data showed that the expression of Na+ channels was increased with differentiated-time dependent manner. Single-cell real-time PCR data demonstrated that the expression of Na+ channel mRNA was increased by 21 days of differentiation in NG108-15 cells. More importantly, the mRNA level of Na+ channels in cells with action potential was higher than that in cells without action potential. Differentiation induces expression of voltage-gated Na+ channels and action potential generation in NG108-15 cells. A high level of the Na+ channel density is required for differentiation-triggered action potential generation.

  4. Method and system for a gas tube switch-based voltage source high voltage direct current transmission system

    Energy Technology Data Exchange (ETDEWEB)

    She, Xu; Chokhawala, Rahul Shantilal; Zhou, Rui; Zhang, Di; Sommerer, Timothy John; Bray, James William

    2016-12-13

    A voltage source converter based high-voltage direct-current (HVDC) transmission system includes a voltage source converter (VSC)-based power converter channel. The VSC-based power converter channel includes an AC-DC converter and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and a DC-AC inverter include at least one gas tube switching device coupled in electrical anti-parallel with a respective gas tube diode. The VSC-based power converter channel includes a commutating circuit communicatively coupled to one or more of the at least one gas tube switching devices. The commutating circuit is configured to "switch on" a respective one of the one or more gas tube switching devices during a first portion of an operational cycle and "switch off" the respective one of the one or more gas tube switching devices during a second portion of the operational cycle.

  5. The Investigation of Field Plate Design in 500 V High Voltage NLDMOS

    Directory of Open Access Journals (Sweden)

    Donghua Liu

    2015-01-01

    Full Text Available This paper presents a 500 V high voltage NLDMOS with breakdown voltage (VBD improved by field plate technology. Effect of metal field plate (MFP and polysilicon field plate (PFP on breakdown voltage improvement of high voltage NLDMOS is studied. The coeffect of MFP and PFP on drain side has also been investigated. A 500 V NLDMOS is demonstrated with a 37 μm drift length and optimized MFP and PFP design. Finally the breakdown voltage 590 V and excellent on-resistance performance (Rsp = 7.88 ohm * mm2 are achieved.

  6. High-Voltage LED Light Engine with Integrated Driver

    Energy Technology Data Exchange (ETDEWEB)

    Soer, Wouter [Lumileds LLC, San Jose, CA (United States)

    2016-02-29

    LED luminaires have seen dramatic changes in cost breakdown over the past few years. The LED component cost, which until recently was the dominant portion of luminaire cost, has fallen to a level of the same order as the other luminaire components, such as the driver, housing, optics etc. With the current state of the technology, further luminaire performance improvement and cost reduction is realized most effectively by optimization of the whole system, rather than a single component. This project focuses on improving the integration between LEDs and drivers. Lumileds has developed a light engine platform based on low-cost high-power LEDs and driver topologies optimized for integration with these LEDs on a single substrate. The integration of driver and LEDs enables an estimated luminaire cost reduction of about 25% for targeted applications, mostly due to significant reductions in driver and housing cost. The high-power LEDs are based on Lumileds’ patterned sapphire substrate flip-chip (PSS-FC) technology, affording reduced die fabrication and packaging cost compared to existing technology. Two general versions of PSS-FC die were developed in order to create the desired voltage and flux increments for driver integration: (i) small single-junction die (0.5 mm2), optimal for distributed lighting applications, and (ii) larger multi-junction die (2 mm2 and 4 mm2) for high-power directional applications. Two driver topologies were developed: a tapped linear driver topology and a single-stage switch-mode topology, taking advantage of the flexible voltage configurations of the new PSS-FC die and the simplification opportunities enabled by integration of LEDs and driver on the same board. A prototype light engine was developed for an outdoor “core module” application based on the multi-junction PSS-FC die and the single-stage switch-mode driver. The light engine meets the project efficacy target of 128 lm/W at a luminous flux

  7. Improvement of high-voltage staircase drive circuit waveform for high-intensity therapeutic ultrasound

    Science.gov (United States)

    Tamano, Satoshi; Jimbo, Hayato; Azuma, Takashi; Yoshizawa, Shin; Fujiwara, Keisuke; Itani, Kazunori; Umemura, Shin-Ichiro

    2016-07-01

    Recently, in the treatment of diseases such as cancer, noninvasive or low-invasive modality, such as high-intensity focused ultrasound (HIFU), has been put into practice as an alternative to open surgery. HIFU induces thermal ablation of the target tissue to be treated. To improve the efficiency of HIFU, we have proposed a “triggered-HIFU” technique, which uses the combination of a short-duration, high-voltage transmission and a long-duration, medium-voltage transmission. In this method, the transmission device must endure high peak voltage for the former and the high time-average power for the latter. The triggered-HIFU sequence requires electronic scanning of the HIFU focus to maximize its thermal efficiency. Therefore, the transmission device must drive an array transducer with the number of elements on the order of a hundred or more, which requires that each part of the device that drives each element must be compact. The purpose of this work is to propose and construct such a transmission device by improving the staircase drive circuit, which we previously proposed. The main point of improvement is that both N and P MOSFETs are provided for each staircase voltage level instead of only one of them. Compared with the previous ultrasonic transmission circuit, high-voltage spikes were significantly reduced, the power consumption was decreased by 26.7%, and the transmission circuit temperature rise was decreased by 14.5 °C in the triggered-HIFU heating mode.

  8. Research on voltage characteristic of the third generation low-light-level image intensifier tube's output signal to noise ratio

    Science.gov (United States)

    Bai, Xiaofeng; Yin, Lei; Hu, Wen; Shi, Feng; Hou, Zhipeng; Shi, Hongli; He, Yingping

    2012-10-01

    Signal to noise ratio is an important parameter to evaluate the 3rd generation low-light-level image intensifier. In this article, voltage in different poles have been changed respectively, output signal to noise ratio referring to different voltages have been studied, and the relationship between each voltage and output signal to noise ratio has been analyzed. The study results show that voltage of photocathode is not less than 150 V, voltage of MCP is between 800 V and 900 V, and voltage of screen is between 5000 V and 6000 V while output signal to noise ratio of filmed image intensifier is optimized. The study in this article is worthwhile for developing signal to noise ratio of the 3rd low-light-level image intensifier sufficiently.

  9. Characteristics and Breakdown Behaviors of Polysilicon Resistors for High Voltage Applications

    Directory of Open Access Journals (Sweden)

    Xiao-Yu Tang

    2015-01-01

    Full Text Available With the rapid development of the power integrated circuit technology, polysilicon resistors have been widely used not only in traditional CMOS circuits, but also in the high voltage applications. However, there have been few detailed reports about the polysilicon resistors’ characteristics, like voltage and temperature coefficients and breakdown behaviors which are critical parameters of high voltage applications. In this study, we experimentally find that the resistance of the polysilicon resistor with a relatively low doping concentration shows negative voltage and temperature coefficients, while that of the polysilicon resistor with a high doping concentration has positive voltage and temperature coefficients. Moreover, from the experimental results of breakdown voltages of the polysilicon resistors, it could be deduced that the breakdown of polysilicon resistors is thermally rather than electrically induced. We also proposed to add an N-type well underneath the oxide to increase the breakdown voltage in the vertical direction when the substrate is P-type doped.

  10. Design of a high voltage input - output ratio dc-dc converter dedicated to small power fuel cell systems

    Science.gov (United States)

    Béthoux, O.; Cathelin, J.

    2010-12-01

    Consuming chemical energy, fuel cells produce simultaneously heat, water and useful electrical power [J.M. Andújar, F. Segura, Renew. Sust. Energy Rev. 13, 2309 (2009)], [J. Larminie, A. Dicks, Fuel Cell Systems Explained, 2nd edn. (John Wiley & Sons, 2003)]. As a matter of fact, the voltage generated by a fuel cell strongly depends on both the load power demand and the operating conditions. Besides, as a result of many design aspects, fuel cells are low voltage and high current electric generators. On the contrary, electric loads are commonly designed for small voltage swing and a high V/I ratio in order to minimize Joule losses. Therefore, electric loads supplied by fuel cells are typically fed by means of an intermediate power voltage regulator. The specifications of such a power converter are to be able to step up the input voltage with a high ratio (a ratio of 10 is a classic situation) and also to work with an excellent efficiency (in order to minimize its size, its weight and its losses) [A. Shahin, B. Huang, J.P. Martin, S. Pierfederici, B. Davat, Energy Conv. Manag. 51, 56 (2010)]. This paper deals with the design of this essential ancillary device. It intends to bring out the best structure for fulfilling this function. Several dc-dc converters with large voltage step-up ratios are introduced. A topology based on a coupled inductor or tapped inductor is closely studied. A detailed modelling is performed with the purpose of providing designing rules. This model is validated with both simulation and implementation. The experimental prototype is based on the following specifications: the fuel cell output voltage ranges from a 50 V open-voltage to a 25 V rated voltage while the load requires a constant 250 V voltage. The studied coupled inductor converter is compared with a classic boost converter commonly used in this voltage elevating application. Even though the voltage regulator faces severe FC specifications, the measured efficiency reaches 96% at the

  11. Development of high voltage lead wires using electron beam irradiation

    Science.gov (United States)

    Hun-Jai, Bae; Ho-Soung, Sohn; Dong-Jung, Choi

    1995-09-01

    It is known to those skilled to the art that the electric wires used in high voltage operating electric equipments such as TV sets, microwave ovens, duplicators and etc., have such a structure that a conductor is coated with an insulating layer which is encapsulated with a protecting jacket layer. The electric wire specification such as UL and CSA requires superior cut-through property and flame-retardant property of the wire for utilization safety. The cut-through property of insulation material, for example, high density polyethylene, can be increased by crosslinking of the polymer. Also the flame-retardant property of jacket material which protects the flammable inner insulation can be raised by flame-retardant formulating of the material. In the wire and cable industry, crosslinking by electron beam processing is more effective than that by chemical processing in the viewpoint of through-put rate of the products. The jacket layer of the wire plays the role of protecting the insulation material from burning. The protecting ability of the jacket is related to its inherent flammability and formability of swollen carbonated layer when burned. Crosslinking of the material gives a good formability of swollen carbonated layer, and it protects the insulation material from direct flame. In formulating the flame-retardant jacket material, a crosslinking system must be considered with base polymers and other flame-retardant additives.

  12. Photoconductivity of high-voltage space insulating materials

    Science.gov (United States)

    Coffey, H. T.; Nanevicz, J. E.; Adamo, R. C.

    1975-01-01

    The dark and photoconductivities of four high voltage spacecraft insulators, Kapton-H, FEP Teflon, Parylene, and fused quartz, were studied under a variety of conditions intended to simulate a space environment. All measurements were made in a vacuum of less than .00001 torr while the temperature was varied from 22 C to 100 C. Some of the samples used employed conventional deposited metal electrodes--others employed electrodes composed either of an electron beam or a plasma formed by ionization of the residual gas in the test chamber. Test results show: (1) Kapton had unusual conduction properties; it conductivity decreased by more than an order of magnitude when heated at 100 C in a vacuum, but ultimately attained a stable and reproducible value. (2) Both Teflon and fused quartz had high dark resistivities but low photoresistivities when exposed to UV. Optical-density measurements revealed that both materials transmitted UV with little attenuation. (3) Parylene was found to have a low but relatively stable resistivity--comparatively minor changes occurred upon heating or illuminating the sample. Optical-density measurements showed that Parylene was absorbent in the UV and would prevent photoemission from the metal electrode on the back surface.

  13. Design of the robust synchronous generator stator voltage regulator based on the interval plant model

    Directory of Open Access Journals (Sweden)

    Stojić Đorđe

    2013-01-01

    Full Text Available In this paper a novel method for the stator voltage regulator of a synchronous generator based on the interval plant mode, is presented. Namely, it is shown in the literature that, in order to design a controller for the first-order compensator, the limited number of interval plants needs to be examined. Consequently, the intervals of the plant model parameter variations used to calculate the four extreme interval plants required for the sequential PI controller design are determined. The controller is designed using frequency-domain-based techniques, while its robust performance is examined using simulation tests.

  14. Control and Protection in Low Voltage Grid with Large Scale Renewable Electricity Generation

    DEFF Research Database (Denmark)

    Mustafa, Ghullam

    (s). Islanding is a situation where electrical system becomes electrically isolated from the rest of the power network and yet continues to be energized by the DG units connected to it. With the increased penetration of DG units, islanded operation of the distribution network is used to improve the reliability...... or voltage in MG decreases or increases respectively. It requires the significant amount of energy available in the power source with very fast response. A VF control cannot be used for wind and solar power generations because they are unpredictable and depend on the weather conditions (i.e. wind speed...

  15. Excitation and voltage regulation for a 95 MVA surge-power generator

    CERN Document Server

    Bayer, K H

    1972-01-01

    The excitation equipment of the 95 MVA surge-power generator, which feeds the main ring magnets of the 28 GeV proton synchrotron at CERN in Geneva, is subject to certain abnormal requirements. They relate both to its dynamic control characteristics and to its accuracy of voltage regulation. These are essential in order to comply with the most stringent conditions made with respect to reproducibility of magnet cycles over the whole duration of an experimenting period of three to four weeks. A special control concept also ensures optimum results in this respect for the dynamic transition regions within a pulse cycle. (4 refs).

  16. High voltage-power frequency electrical heating in-situ conversion technology of oil shale

    Science.gov (United States)

    Sun, Youhong; Yang, Yang; Lopatin, Vladimir; Guo, Wei; Liu, Baochang; Yu, Ping; Gao, Ke; Ma, Yinlong

    2014-05-01

    With the depletion of conventional energy sources,oil shale has got much attention as a new type of energy resource,which is rich and widespread in the world.The conventional utilization of oil shale is mainly focused on resorting to produce shale oil and fuel gas with low extraction efficiency about one in a million due to many shortcomings and limitations.And the in-situ conversion of oil shale,more environmentally friendly,is still in the experimental stage.High voltage-power frequency electrical heating in-situ conversion of oil shale is a new type of in-situ pyrolysis technology.The main equipment includes a high voltage-power frequency generator and interior reactor. The high voltage-power frequency generator can provide a voltage between 220-8000 V which can be adjusted in real time according to the actual situation.Firstly,high voltage is used to breakdown the oil shale to form a dendritic crack between two electrodes providing a conductive channel inside the oil shale rock.And then the power frequency(220V) is used to generate the electric current for heating the internal surface of conductive channel,so that the energy can be transmitted to the surrounding oil shale.When the temperature reaches 350 degree,the oil shale begins to pyrolysis.In addition,the temperature in the conductive channel can be extremely high with high voltage,which makes the internal surface of conductive channel graphitization and improves its heat conduction performance.This technology can successfully make the oil shale pyrolysis, based on a lot of lab experiments,and also produce the combustible shale oil and fuel gas.Compared to other in-situ conversion technology,this method has the following advantages: high speed of heating oil shale,the equipment underground is simple,and easy to operate;it can proceed without the limitation of shale thickness, and can be used especially in the thin oil shale reservoir;the heating channel is parallel to the oil shale layers,which has more

  17. BEHAVIOUR OF BACKFILL MATERIALS FOR ELECTRICAL GROUNDING SYSTEMS UNDER HIGH VOLTAGE CONDITIONS

    Directory of Open Access Journals (Sweden)

    S. C. LIM

    2015-06-01

    Full Text Available Backfill materials like Bentonite and cement are effective in lowering grounding resistance of electrodes for a considerable period. During lightning, switching impulses and earth fault occurrences in medium and high voltage networks, the grounding system needs to handle extremely high currents either for a short duration or prolonged period respectively. This paper investigates the behaviour of bentonite, cement and sand under impulse and alternating high voltage (50Hz conditions. Fulguritic-formation was observed in all materials under alternating high voltage. The findings reveal that performance of grounding systems under high voltage conditions may significantly change from the outcomes anticipated at design stage.

  18. Index-Based Assessment of Voltage Rise and Reverse Power Flow Phenomena in a Distribution Feeder Under High PV Penetration

    DEFF Research Database (Denmark)

    Hasheminamin, Maryam; Agelidis, Vassilios G.; Salehi, Vahid

    2015-01-01

    The proliferation of photovoltaic (PV) generation in low- and medium-voltage distribution networks is expected to continue. Qualified studies can quantify adverse impacts of high PV penetration on distribution networks and assist utilities in decision making. This paper proposes an index-based me......The proliferation of photovoltaic (PV) generation in low- and medium-voltage distribution networks is expected to continue. Qualified studies can quantify adverse impacts of high PV penetration on distribution networks and assist utilities in decision making. This paper proposes an index...... are used to confirm the effectiveness of the proposed indices. This paper derives the acceptable range of the proposed indices and safe margin, which have been compared with the basic active power curtailment method with no constraint, in order to avoid voltage rise. The IEEE 69-bus network is also...

  19. Offshore wind power plants with VSC-HVDC transmission : Grid code compliance optimization and the effect on high voltage ac transmission system

    NARCIS (Netherlands)

    Ndreko, M.

    2017-01-01

    The development of large offshore wind power generation in the North Sea has been significantly accelerated in the last years. The large distance from shore in combination with the need for large transmission capacity has raised the interest for the voltage source converter high voltage direct

  20. High-voltage sharp-recovery 4H:SiC drift diodes: Theoretical estimation of limiting parameters

    Science.gov (United States)

    Ivanov, P. A.; Grekhov, I. V.

    2015-06-01

    A simple mathematical model of 4H:SiC sharp-recovery drift diodes with a p +- p- n 0- n + structure. With this model, the limiting electrical parameters of high-voltage (2-10 kV) pulse generators built around these diodes are theoretically estimated.

  1. An Underappreciated Radiation Hazard from High Voltage Electrodes in Vacuum.

    Science.gov (United States)

    West, Adam D; Lasner, Zack; DeMille, David; West, Elizabeth P; Panda, Cristian D; Doyle, John M; Gabrielse, Gerald; Kryskow, Adam; Mitchell, Corinne

    2017-01-01

    The use of high voltage (HV) electrodes in vacuum is commonplace in physics laboratories. In such systems, it has long been known that electron emission from an HV cathode can lead to bremsstrahlung x rays; indeed, this is the basic principle behind the operation of standard x-ray sources. However, in laboratory setups where x-ray production is not the goal and no electron source is deliberately introduced, field-emitted electrons accelerated by HV can produce x rays as an unintended hazardous byproduct. Both the level of hazard and the safe operating regimes for HV vacuum electrode systems are not widely appreciated, at least in university laboratories. A reinforced awareness of the radiation hazards associated with vacuum HV setups would be beneficial. The authors present a case study of a HV vacuum electrode device operated in a university atomic physics laboratory. They describe the characterization of the observed x-ray radiation, its relation to the observed leakage current in the device, the steps taken to contain and mitigate the radiation hazard, and suggested safety guidelines.

  2. An Underappreciated Radiation Hazard from High Voltage Electrodes in Vacuum

    CERN Document Server

    West, Adam; DeMille, David; West, Elizabeth; Panda, Cristian; Doyle, John; Gabrielse, Gerald; Kryskow, Adam; Mitchell, Corinne

    2016-01-01

    The use of high voltage (HV) electrodes in vacuum is commonplace in physics laboratories. In such systems, it has long been known that electron emission from an HV cathode can lead to bremsstrahlung X-rays; indeed, this is the basic principle behind the operation of standard X-ray sources. However, in laboratory setups where X-ray production is not the goal and no electron source is deliberately introduced, field-emitted electrons accelerated by HV can produce X-rays as an unintended hazardous byproduct. Both the level of hazard and the safe operating regimes for HV vacuum electrode systems are not widely appreciated, at least in university laboratories. A reinforced awareness of the radiation hazards associated with vacuum HV setups would be beneficial. We present a case study of a HV vacuum electrode device operated in a university atomic physics laboratory. We describe the characterisation of the observed X-ray radiation, its relation to the observed leakage current in the device, the steps taken to contai...

  3. Effect of high solenoidal magnetic fields on breakdown voltages of high vacuum 805 MHz cavities

    Energy Technology Data Exchange (ETDEWEB)

    Moretti, A.; Bross, A.; Geer, S.; Qian, Z.; /Fermilab; Norem, J.; /Argonne; Li, D.; Zisman, M.; /LBL, Berkeley; Torun, Y.; /IIT, Chicago; Rimmer, R.; /Jefferson Lab; Errede,; /Illinois U., Urbana

    2005-10-01

    There is an on going international collaboration studying the feasibility and cost of building a muon collider or neutrino factory [1,2]. An important aspect of this study is the full understanding of ionization cooling of muons by many orders of magnitude for the collider case. An important muon ionization cooling experiment, MICE [3], has been proposed to demonstrate and validate the technology that could be used for cooling. Ionization cooling is accomplished by passing a high-emittance muon beam alternately through regions of low Z material, such as liquid hydrogen, and very high accelerating RF Cavities within a multi-Tesla solenoidal field. To determine the effect of very large solenoidal magnetic fields on the generation of dark current, x-rays and on the breakdown voltage gradients of vacuum RF cavities, a test facility has been established at Fermilab in Lab G. This facility consists of a 12 MW 805 MHz RF station and a large warm bore 5 T solenoidal superconducting magnet containing a pill box type cavity with thin removable window apertures. This system allows dark current and breakdown studies of different window configurations and materials. The results of this study will be presented. The study has shown that the peak achievable accelerating gradient is reduced by a factor greater than 2 when solenoidal field of greater than 2 T are applied to the cavity.

  4. Optimization of kV Selection on Third-generation High-pitch Dual-source Coronary CT Angiography Using Ultra-low Contrast Media Protocols in Patients with Body Mass Index between 20-30 kg/m2 under Automatic Tube Voltage Selection.

    Science.gov (United States)

    Wang, Ming; Yi, Yan; Cao, Jian; Wang, Yining; Qi, Bing; Ma, Shuo; Wang, Yun

    2017-02-20

    Objective To investigate the application of automatic tube voltage selection (CARE-kV)coronary CT angiography (CCTA)using ultra-low contrast media (CM)protocols in patients with body mass index (BMI)between 20 kg/m2 and 30 kg/m2 on third-generation dual-source CT (DSCT). Methods We prospectively included 134 consecutive patients with BMI between 20 kg/m2 and 30 kg/m2who underwent CARE-kV prospective high-pitch CCTA on third-generation DSCT using the ultra-low CM protocols and divided them into two groups according to the CARE-kV results:70 kV group(n=91):65 patients with normal BMI(20 kg/m2≤BMI≤25 kg/m2)and 26 patients with high BMI(25 kg/m2image quality (IQ),and results of patients in each group and subgroup were evaluated and compared.ResultsThe ED of 70 kV group was(0.24±0.04)mSv,which was 53% lower(H=3.37,P=0.02)than that of 80 kV group [(0.51±0.05)mSv]. No significant difference of CNR and SNR had been found in normal BMI patients(H=1.81,P=0.23)and high BMI patients (H=0.91,P=0.84)among 70 kV group and 80 kV group,as well as the subjective IQ in normal BMI patients(Z=0.79,P=0.76)and high BMI patients (Z=0.77,P=0.81)among 70 kV group and 80 kV group. Conclusion sWhen patients with BMI between 20 kg/m2 and 30 kg/m2 receive CARE-kV prospective high-pitch CCTA on third-generation DSCT,the CARE-kV results for a portion of patients may be higher than other patients with the same BMI level,so as to guarantee the equivalent IQ. The CARE-kV can help to select the patients' optimal tube voltage value more accurately and reasonably.

  5. Voltage Unbalance and Harmonic Compensation in Microgrids by Cooperation of Distributed Generators and Active Power Filters

    DEFF Research Database (Denmark)

    Hashempour, Mohammad M.; Savaghebi, Mehdi; Quintero, Juan Carlos Vasquez

    2016-01-01

    , selective virtual impedance and voltage/current regulators. Based on the secondary control, at first voltage harmonic compensation and voltage unbalance compensation of point of common coupling (PCC), that might includes sensitive loads, is carried out by DGs. Voltage compensation of PCC by DGs may cause...

  6. Proportional-Type Performance Recovery DC-Link Voltage Tracking Algorithm for Permanent Magnet Synchronous Generators

    Directory of Open Access Journals (Sweden)

    Seok-Kyoon Kim

    2017-09-01

    Full Text Available This study proposes a disturbance observer-based proportional-type DC-link voltage tracking algorithm for permanent magnet synchronous generators (PMSGs. The proposed technique feedbacks the only proportional term of the tracking errors, and it contains the nominal static and dynamic feed-forward compensators coming from the first-order disturbance observers. It is rigorously proved that the proposed method ensures the performance recovery and offset-free properties without the use of the integrators of the tracking errors. A wind power generation system has been simulated to verify the efficacy of the proposed method using the PSIM (PowerSIM software with the DLL (Dynamic Link Library block.

  7. A novel method to measure the generated voltage of a ZnO nanogenerator

    Energy Technology Data Exchange (ETDEWEB)

    Heever, Stanley T van den; Buettner, Ulrich; Perold, Willem J, E-mail: tsvdh@sun.ac.za [Department of Electrical and Electronic Engineering, Stellenbosch University, Cnr Banghoek Road and Joubert Street, 7600, Stellenbosch (South Africa)

    2011-09-30

    A novel method to measure the output voltage of a zinc oxide nanowire nanogenerator is proposed. Various tests are performed to verify that the output voltage does indeed originate from the nanogenerator and not from environmental noise. Although noise does influence the output voltage measurements, the output voltage is easily distinguishable from the measured noise. It is also shown that the method can be used to determine the internal resistance of the nanogenerator by measuring the output voltage over different output resistors.

  8. High-Mixed-Voltage Analog and RF Circuit Techniques for Nanoscale CMOS

    CERN Document Server

    Mak, Pui-In

    2012-01-01

    This book presents high-/mixed-voltage analog and radio frequency (RF) circuit techniques for developing low-cost multistandard wireless receivers in nm-length CMOS processes.  Key benefits of high-/mixed-voltage RF and analog CMOS circuits are explained, state-of-the-art examples are studied, and circuit solutions before and after voltage-conscious design are compared. Three real design examples are included, which demonstrate the feasibility of high-/mixed-voltage circuit techniques.    Provides a valuable summary and real case studies of the state-of-the-art in high-/mixed-voltage circuits and systems; Includes novel high-/mixed-voltage analog and RF circuit techniques – from concept to practice; Describes the first high-voltage-enabled mobile-TVRF front-end in 90nm CMOS and the first mixed-voltage full-band mobile-TV Receiver in 65nm CMOS; Demonstrates the feasibility of high-/mixed-voltage circuit techniques with real design examples.  

  9. Electric Power High-Voltage Transmission Lines: Design Options, Cost, and Electric and Magnetic Field Levels

    Energy Technology Data Exchange (ETDEWEB)

    Stoffel, J. B. [Argonne National Lab. (ANL), Argonne, IL (United States). Environmental Assessment Division. Electronics and Computing Technologies Division; Pentecost, E. D. [Argonne National Lab. (ANL), Argonne, IL (United States). Environmental Assessment Division; Roman, R. D. [Argonne National Lab. (ANL), Argonne, IL (United States). Environmental Assessment Division; Traczyk, P. A. [Argonne National Lab. (ANL), Argonne, IL (United States). Environmental Assessment Division

    1994-11-01

    The aim of this report is to provide background information about (1) the electric and magnetic fields (EMFs) of high-voltage transmission lines at typical voltages and line configurations and (2) typical transmission line costs to assist preparers and reviewers of the section on alternatives in environmental documents. This report will give the reviewing individual a better appreciation of the factors affecting EMF strengths near high-voltage transmission lines and the approaches that might be used to reduce EMF impacts on humans and other biological species in the vicinity of high-voltage overhead or underground alternating-current (ac) or direct-current (dc) transmission lines.

  10. CFD Simulation of Transonic Flow in High-Voltage Circuit Breaker

    Directory of Open Access Journals (Sweden)

    Xiangyang Ye

    2012-01-01

    Full Text Available A high-voltage circuit breaker is an indispensable piece of equipment in the electric transmission and distribution systems. Transonic flow typically occurs inside breaking chamber during the current interruption, which determines the insulating characteristics of gas. Therefore, accurate compressible flow simulations are required to improve the prediction of the breakdown voltages in various test duties of high-voltage circuit breakers. In this work, investigation of the impact of the solvers on the prediction capability of the breakdown voltages in capacitive switching is presented. For this purpose, a number of compressible nozzle flow validation cases have been presented. The investigation is then further extended for a real high-voltage circuit breaker geometry. The correlation between the flow prediction accuracy and the breakdown voltage prediction capability is identified.

  11. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Fasanella, Giuseppe

    2016-01-01

    The CMS Electromagnetic Calorimeter utilizes scintillating lead tungstate crystals, with avalanche photodiodes (APD) as photo-detectors in the barrel part. 1224 HV channels bias groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  12. Design, Implementation, Modeling, and Optimization of Next Generation Low-Voltage Power MOSFETs

    Science.gov (United States)

    Yoo, Abraham

    In this thesis, next generation low-voltage integrated power semiconductor devices are proposed and analyzed in terms of device structure and layout optimization techniques. Both approaches strive to minimize the power consumption of the output stage in DC-DC converters. In the first part of this thesis, we present a low-voltage CMOS power transistor layout technique, implemented in a 0.25mum, 5 metal layer standard CMOS process. The hybrid waffle (HW) layout was designed to provide an effective trade-off between the width of diagonal source/drain metal and the active device area, allowing more effective optimization between switching and conduction losses. In comparison with conventional layout schemes, the HW layout exhibited a 30% reduction in overall on-resistance with 3.6 times smaller total gate charge for CMOS devices with a current rating of 1A. Integrated DC-DC buck converters using HW output stages were found to have higher efficiencies at switching frequencies beyond multi-MHz. In the second part of the thesis, we present a CMOS-compatible lateral superjunction FINFET (SJ-FINFET) on a SOI platform. One drawback associated with low-voltage SJ devices is that the on-resistance is not only strongly dependent on the drift doping concentration but also on the channel resistance as well. To resolve the issue, a SJ-FINFET structure consisting of a 3D trench gate and SJ drift region was developed to minimize both channel and drift resistances. Several prototype devices were fabricated in a 0.5mum CMOS compatible process with nine masking layers. In comparison with conventional SJ-LDMOSFETs, the fabricated SJ-FINFETs demonstrated approximately 30% improvement in Ron,sp. This is a positive indication that the SJ-FINFET can become a competitive power device for sub-100V rating applications.

  13. High-voltage microdischarge as a source of extreme density plasma

    Science.gov (United States)

    Levko, Dmitry; Raja, Laxminarayan L.

    2018-01-01

    The generation of non-equilibrium (cold) plasmas with the densities ˜1019-1020 cm-3 in a fully ionized state has been reported in several recent experimental studies. In this work, we simulate a high-voltage high-pressure nanosecond xenon microdischarge that provides an easily accessible source of such a fully ionized cold plasma. In our studies, we use self-consistent one-dimensional Particle-in-Cell Monte Carlo collisions model. We observe that the generation of a fully ionized plasma can be driven by the secondary electron emission from the cathode. Initially, secondary electrons propagate through the collisional sheath and generate the plasma with a density ˜1018 cm-3. Such a dense plasma generated in the vicinity of the cathode sheath makes sheath collisionless, which allows the acceleration of secondary electrons to keV energies. These energetic electrons are responsible for the generation of fully ionized plasma. We also obtain that accounting for the electron field emission allows faster generation of fully ionized plasma, although the main physical mechanisms remain unchanged.

  14. Large-Scale Electrochemical Energy Storage in High Voltage Grids: Overview of the Italian Experience

    Directory of Open Access Journals (Sweden)

    Roberto Benato

    2017-01-01

    Full Text Available This paper offers a wide overview on the large-scale electrochemical energy projects installed in the high voltage Italian grid. Detailed descriptions of energy (charge/discharge times of about 8 h and power intensive (charge/discharge times ranging from 0.5 h to 4 h installations are presented with some insights into the authorization procedures, safety features, and ancillary services. These different charge/discharge times reflect the different operation uses inside the electric grid. Energy intensive storage aims at decoupling generation and utilization since, in the southern part of Italy, there has been a great growth of wind farms: these areas are characterized by a surplus of generation with respect to load absorption and to the net transport capacity of the 150 kV high voltage backbones. Power intensive storage aims at providing ancillary services inside the electric grid as primary and secondary frequency regulation, synthetic rotational inertia, and further functionalities. The return on experience of Italian installations will be able to play a key role also for other countries and other transmission system operators.

  15. High-tension corona controlled ozone generator for environment protection

    Science.gov (United States)

    Vijayan, T.; Patil, Jagadish G.

    2010-02-01

    Engineering details of a high voltage driven corona-plasma ozone generator are described. The plasma diode of generator has coaxial cylindrical geometry with cathode located inside anode. Cathode is made of a large number of radial gas nozzles arranged on central tubular mast which admits oxygen gas. The sharp endings of the nozzles along with a set of corona rings create the high electric field at the cathode required for formation of dense corona plume responsible for O3 evolution. A model of coronal plasma generation and ozone production is presented. The plasma formation is strongly dependent on the electric field and temperature in side diode where a high electron density in a low temperature negative corona is suited for high ozone yields. These are established by suitable regulation of A-K gap, voltage, oxygen pressure, and cathode-nozzle population.

  16. High Bandwidth Zero Voltage Injection Method for Sensorless Control of PMSM

    DEFF Research Database (Denmark)

    Ge, Xie; Lu, Kaiyuan; Kumar, Dwivedi Sanjeet

    2014-01-01

    High frequency signal injection is widely used in PMSM sensorless control system for low speed operations. The conventional voltage injection method often needs filters to obtain particular harmonic component in order to estimate the rotor position; or it requires several voltage pulses to be inj......High frequency signal injection is widely used in PMSM sensorless control system for low speed operations. The conventional voltage injection method often needs filters to obtain particular harmonic component in order to estimate the rotor position; or it requires several voltage pulses...

  17. Electronics drivers for high voltage dielectric electro active polymer (DEAP) applications

    Science.gov (United States)

    Zhang, Zhe; Andersen, Michael A. E.

    2015-04-01

    Dielectric electro active polymer (DEAP) can be used in actuation, sensing and energy harvesting applications, but driving the DEAP based actuators and generators has three main challenges from a power electronics standpoint, i.e. high voltage (around 2.5 kV), nonlinearity, and capacitive behavior. In this paper, electronics divers for heating valves, loud speakers, incremental motors, and energy harvesting are reviewed, studied and developed in accordance with their corresponding specifications. Due to the simplicity and low power capacity (below 10W), the reversible Fly-back converters with both magnetic and piezoelectric transformers are employed for the heating valve and incremental motor application, where only ON/OFF regulation is adopted for energy saving; as for DEAP based energy harvesting, the noisolated Buck/Boost converter is used, due to the system high power capacity (above 100W), but the voltage balancing across the series-connected high voltage IGBTs is a critical issue and accordingly a novel gate driver circuitry is proposed and equipped; due to the requirements of the audio products, such as low distortion and noise, the multi-level Buck converter based Class-D amplifier, because of its high control linearity, is implemented for the loud speaker applications. A synthesis among those converter topologies and control techniques is given; therefore, for those DEAP based applications, their diversity and similarity of electronics drivers, as well as the key technologies employed are analyzed. Therefore a whole picture of how to choose the proper topologies can be revealed. Finally, the design guidelines in order to achieve high efficiency and reliability are discussed.

  18. Design of High Performance Permanent-Magnet Synchronous Wind Generators

    Directory of Open Access Journals (Sweden)

    Chun-Yu Hsiao

    2014-11-01

    Full Text Available This paper is devoted to the analysis and design of high performance permanent-magnet synchronous wind generators (PSWGs. A systematic and sequential methodology for the design of PMSGs is proposed with a high performance wind generator as a design model. Aiming at high induced voltage, low harmonic distortion as well as high generator efficiency, optimal generator parameters such as pole-arc to pole-pitch ratio and stator-slot-shoes dimension, etc. are determined with the proposed technique using Maxwell 2-D, Matlab software and the Taguchi method. The proposed double three-phase and six-phase winding configurations, which consist of six windings in the stator, can provide evenly distributed current for versatile applications regarding the voltage and current demands for practical consideration. Specifically, windings are connected in series to increase the output voltage at low wind speed, and in parallel during high wind speed to generate electricity even when either one winding fails, thereby enhancing the reliability as well. A PMSG is designed and implemented based on the proposed method. When the simulation is performed with a 6 Ω load, the output power for the double three-phase winding and six-phase winding are correspondingly 10.64 and 11.13 kW. In addition, 24 Ω load experiments show that the efficiencies of double three-phase winding and six-phase winding are 96.56% and 98.54%, respectively, verifying the proposed high performance operation.

  19. Voltage Control of PM Synchronous Motor Driven PM Synchronous Generator System Using Recurrent Wavelet Neural Network Controller

    Directory of Open Access Journals (Sweden)

    C.H. Lin

    2013-04-01

    Full Text Available In this paper the two novel recurrent wavelet neural network (RWNN controllers are proposed for controlling output direct current (DC voltage of the rectifier and output alternate current (AC voltage of the inverter. The output power of the rectifier and the inverter is provided by three-phase permanent magnet synchronous generator (PMSG system directly-driven by permanent magnet synchronous motor (PMSM. Firstly, the field-oriented mechanism is implemented for controlling output of the PMSG system. Then, one RWNN controller is developed for controlling rectifier to convert AC voltage into DC link voltage and the other RWNN controller is implemented for controlling inverter to convert DC link voltage into AC line voltage. Moreover, two online trained RWNNs using backpropagation learning algorithms are developed for regulating both the DC link voltage of the rectifier and the AC line voltage of the inverter. Finally, the effectiveness and advantages of the proposed two RWNN controllers are demonstrated in comparison with the two PI controllers from some experimental results.

  20. A novel series connected batteries state of high voltage safety monitor system for electric vehicle application.

    Science.gov (United States)

    Jiaxi, Qiang; Lin, Yang; Jianhui, He; Qisheng, Zhou

    2013-01-01

    Batteries, as the main or assistant power source of EV (Electric Vehicle), are usually connected in series with high voltage to improve the drivability and energy efficiency. Today, more and more batteries are connected in series with high voltage, if there is any fault in high voltage system (HVS), the consequence is serious and dangerous. Therefore, it is necessary to monitor the electric parameters of HVS to ensure the high voltage safety and protect personal safety. In this study, a high voltage safety monitor system is developed to solve this critical issue. Four key electric parameters including precharge, contact resistance, insulation resistance, and remaining capacity are monitored and analyzed based on the equivalent models presented in this study. The high voltage safety controller which integrates the equivalent models and control strategy is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated, and the online electric parameters monitor strategy is analyzed and discussed. The test results indicate that the high voltage safety monitor system designed in this paper is suitable for EV application.

  1. 30 CFR 77.704 - Work on high-voltage lines; deenergizing and grounding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Work on high-voltage lines; deenergizing and grounding. 77.704 Section 77.704 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... OF UNDERGROUND COAL MINES Grounding § 77.704 Work on high-voltage lines; deenergizing and grounding...

  2. 30 CFR 75.705 - Work on high-voltage lines; deenergizing and grounding.

    Science.gov (United States)

    2010-07-01

    ... grounding. 75.705 Section 75.705 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.705 Work on high-voltage lines; deenergizing and grounding. High-voltage lines, both on the surface and...

  3. 30 CFR 77.802 - Protection of high-voltage circuits; neutral grounding resistors; disconnecting devices.

    Science.gov (United States)

    2010-07-01

    ... grounding resistors; disconnecting devices. 77.802 Section 77.802 Mineral Resources MINE SAFETY AND HEALTH... of high-voltage circuits; neutral grounding resistors; disconnecting devices. High-voltage circuits... grounded through a suitable resistor at the source transformers, and a grounding circuit, originating at...

  4. 76 FR 26183 - Safety Zone; Repair of High Voltage Transmission Lines to Logan International Airport, Saugus...

    Science.gov (United States)

    2011-05-06

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone; Repair of High Voltage Transmission Lines... transmission lines to Logan Airport. This safety zone is required to provide for the safety of life on navigable waters during the repair of high voltage transmission lines. Entering into, transiting through...

  5. 75 FR 20918 - High-Voltage Continuous Mining Machine Standard for Underground Coal Mines

    Science.gov (United States)

    2010-04-22

    ... From the Federal Register Online via the Government Publishing Office ] DEPARTMENT OF LABOR Mine Safety and Health Administration 30 CFR Parts 18 and 75 RIN 1219-AB34 High-Voltage Continuous Mining... the table titled Table 10--HIGH VOLTAGE TRAILING CABLE AMPACITIES AND OUTSIDE DIAMETERS, the first...

  6. A Novel Series Connected Batteries State of High Voltage Safety Monitor System for Electric Vehicle Application

    Directory of Open Access Journals (Sweden)

    Qiang Jiaxi

    2013-01-01

    Full Text Available Batteries, as the main or assistant power source of EV (Electric Vehicle, are usually connected in series with high voltage to improve the drivability and energy efficiency. Today, more and more batteries are connected in series with high voltage, if there is any fault in high voltage system (HVS, the consequence is serious and dangerous. Therefore, it is necessary to monitor the electric parameters of HVS to ensure the high voltage safety and protect personal safety. In this study, a high voltage safety monitor system is developed to solve this critical issue. Four key electric parameters including precharge, contact resistance, insulation resistance, and remaining capacity are monitored and analyzed based on the equivalent models presented in this study. The high voltage safety controller which integrates the equivalent models and control strategy is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated, and the online electric parameters monitor strategy is analyzed and discussed. The test results indicate that the high voltage safety monitor system designed in this paper is suitable for EV application.

  7. Particle flows to shape and voltage surface discontinuities in the electron sheath surrounding a high voltage solar array in LEO

    Science.gov (United States)

    Metz, Roger N.

    1991-01-01

    This paper discusses the numerical modeling of electron flows from the sheath surrounding high positively biased objects in LEO (Low Earth Orbit) to regions of voltage or shape discontinuity on the biased surfaces. The sheath equations are derived from the Two-fluid, Warm Plasma Model. An equipotential corner and a plane containing strips of alternating voltage bias are treated in two dimensions. A self-consistent field solution of the sheath equations is outlined and is pursued through one cycle. The electron density field is determined by numerical solution of Poisson's equation for the electrostatic potential in the sheath using the NASCAP-LEO relation between electrostatic potential and charge density. Electron flows are calculated numerically from the electron continuity equation. Magnetic field effects are not treated.

  8. Highly Efficient Vector-Inversion Pulse Generators

    Science.gov (United States)

    Rose, Franklin

    2004-01-01

    Improved transmission-line pulse generators of the vector-inversion type are being developed as lightweight sources of pulsed high voltage for diverse applications, including spacecraft thrusters, portable x-ray imaging systems, impulse radar systems, and corona-discharge systems for sterilizing gases. In this development, more than the customary attention is paid to principles of operation and details of construction so as to the maximize the efficiency of the pulse-generation process while minimizing the sizes of components. An important element of this approach is segmenting a pulse generator in such a manner that the electric field in each segment is always below the threshold for electrical breakdown. One design of particular interest, a complete description of which was not available at the time of writing this article, involves two parallel-plate transmission lines that are wound on a mandrel, share a common conductor, and are switched in such a manner that the pulse generator is divided into a "fast" and a "slow" section. A major innovation in this design is the addition of ferrite to the "slow" section to reduce the size of the mandrel needed for a given efficiency.

  9. High-explosive-driven delay line pulse generator

    Energy Technology Data Exchange (ETDEWEB)

    Shearer, J.W.

    1982-11-15

    The inclusion of a delay line circuit into the design of a high-explosive-driven generator shortens the time constant of the output pulse. After a brief review of generator concepts and previously described pulse-shortening methods, a geometry is presented which incorporates delay line circuit techcniques into a coil generator. The circuit constants are adjusted to match the velocity of the generated electromagnetic wave to the detonation velocity of the high explosive. The proposed generator can be modeled by adding a variable inductance term to the telegrapher's equation. A particular solution of this equation is useful for exploring the operational parameters of the generator. The duration of the electromagnetic pulse equals the radial expansion time of the high-explosive-driven armature until it strikes the coil. Because the impedance of the generator is a constant, the current multiplication factor is limited only by nonlinear effects such as voltage breakdown, diffusion, and compression at high energies.

  10. Decentralized Voltage Control Coordination of On-Load Tap Changer Transformers, Distributed Generation Units and Flexible Loads

    DEFF Research Database (Denmark)

    Romani Dalmau, Aina; Martinez Perez, David; Diaz de Cerio Mendaza, Iker

    2015-01-01

    approach is introduced in order to coordinate the voltage control capability from different assets in medium voltage networks. In this sense, the on-load tap changer strategy of the primary substation and the power factor control of wind turbines and combined heat and power plants are combined...... of the on-load tap changer and the reactive power from dispersed generation while maximizing the capacity usage of the Power-to-Gas load....

  11. Superconcentrated electrolytes for a high-voltage lithium-ion battery

    Science.gov (United States)

    Wang, Jianhui; Yamada, Yuki; Sodeyama, Keitaro; Chiang, Ching Hua; Tateyama, Yoshitaka; Yamada, Atsuo

    2016-01-01

    Finding a viable electrolyte for next-generation 5 V-class lithium-ion batteries is of primary importance. A long-standing obstacle has been metal-ion dissolution at high voltages. The LiPF6 salt in conventional electrolytes is chemically unstable, which accelerates transition metal dissolution of the electrode material, yet beneficially suppresses oxidative dissolution of the aluminium current collector; replacing LiPF6 with more stable lithium salts may diminish transition metal dissolution but unfortunately encounters severe aluminium oxidation. Here we report an electrolyte design that can solve this dilemma. By mixing a stable lithium salt LiN(SO2F)2 with dimethyl carbonate solvent at extremely high concentrations, we obtain an unusual liquid showing a three-dimensional network of anions and solvent molecules that coordinate strongly to Li+ ions. This simple formulation of superconcentrated LiN(SO2F)2/dimethyl carbonate electrolyte inhibits the dissolution of both aluminium and transition metal at around 5 V, and realizes a high-voltage LiNi0.5Mn1.5O4/graphite battery that exhibits excellent cycling durability, high rate capability and enhanced safety. PMID:27354162

  12. Utilization of low voltage D-T neutron generators in neutron physics studies

    Energy Technology Data Exchange (ETDEWEB)

    Singkarat, S.

    1995-08-01

    In a small nuclear laboratory of a developing country a low voltage D-T neutron generator can be a very useful scientific apparatus. Such machines have been used successfully for more than 40 years in teaching and scientific research. The original continuous mode 150-kV D-T neutron generator has been modified to have also a capability of producing 2-ns pulsed neutrons. Together with a carefully designed 10 m long flight path collimator and shielding of a 25 cm diameter {center_dot} 10 cm thick BC-501 neutron detector, the pulsing system was successfully used for measuring the double differential cross-section (DDX) of natural iron for 14.1-MeV neutron from the angle of 30 deg to 150 deg in 10 deg steps. In order to extend the utility of the generator, two methods for converting the almost monoenergetic 14-MeV neutrons to monoenergetic neutrons of lower energy were proposed and tested. The first method uses a pulsed neutron generator and the second method uses an ordinary continuous mode generator. The latter method was successfully used to measure the scintillation light output of a 1.4 cm diameter spherical NE-213 scintillation detector. The neutron generator has also been used in the continuous search for improved neutron detection techniques. There is a proposal, based on Monte Carlo calculations, of using a scintillation fiber for a fast neutron spectrometer. Due to the slender shape of the fiber, the pattern of produced light gives a peak in the pulse height spectrum instead of the well-known rectangular-like distribution, when the fiber is bombarded end-on by a beam of 14-MeV neutrons. Experimental investigations were undertaken. Detailed investigations on the light transportation property of a short fiber were performed. The predicted peak has not yet been found but the fiber detector may be developed as a directional discrimination fast neutron detector. 18 refs.

  13. First test of a high voltage feedthrough for liquid Argon TPCs connected to a 300 kV power supply

    CERN Document Server

    Cantini, C; Bueno, L Molina; Murphy, S; Radics, B; Regenfus, C; Rigaut, Y-A; Rubbia, A; Sergiampietri, F; Viant, T; Wu, S

    2016-01-01

    Voltages above a hundred kilo-volt will be required to generate the drift field of future very large liquid Argon Time Projection Chambers. The most delicate component is the feedthrough whose role is to safely deliver the very high voltage to the cathode through the thick insulating walls of the cryostat without compromising the purity of the argon inside. This requires a feedthrough that is typically meters long and carefully designed to be vacuum tight and have small heat input. Furthermore, all materials should be carefully chosen to allow operation in cryogenic conditions. In addition, electric fields in liquid argon should be kept below a threshold to reduce risks of discharges. The combination of all above requirements represents significant challenges from the design and manufacturing perspective. In this paper, we report on the successful operation of a feedthrough satisfying all the above requirements. The details of the feedthrough design and its manufacturing steps are provided. Very high voltages...

  14. Coordinated control of a DFIG-based wind-power generation system with SGSC under distorted grid voltage conditions

    DEFF Research Database (Denmark)

    Yao, Jun; Li, Qing; Chen, Zhe

    2013-01-01

    This paper presents a coordinated control method for a doubly-fed induction generator (DFIG)-based wind-power generation system with a series grid-side converter (SGSC) under distorted grid voltage conditions. The detailed mathematical models of the DFIG system with SGSC are developed in the mult...

  15. The monitoring results of electromagnetic radiation of 110-kV high-voltage lines in one urban location in Chongqing P.R. China.

    Science.gov (United States)

    Qin, Qi-Zhong; Chen, Yu; Fu, Ting-Ting; Ding, Li; Han, Ling-Li; Li, Jian-Chao

    2012-03-01

    To understand electromagnetic radiation field strength and its influencing factors of certain 110-kV high-voltage lines in one urban area of Chongqing by measuring 110-kV high-voltage line's electromagnetic radiation level. According to the methodology as determined by the National Hygienic Standards, we selected certain adjacent residential buildings, high-voltage lines along a specific street and selected different distances around its vertical projection point as monitoring points. The levels of electromagnetic radiations were measured respectively. In this investigation within the frequency of 5-1,000 Hz both the electric field strength and magnetic field strength of each monitoring sites were lower than the public exposure standards as determined by the International Commission on Non-Ionizing Radiation Protection. However, the electrical field strength on the roof adjacent to the high-voltage lines was significantly higher than that as measured on the other floors in the same buildings (p electromagnetic radiation measurements of different monitoring points, under the same high-voltage lines, showed the location which is nearer the high-voltage line maintain a consistently higher level of radiation than the more distant locations (p Electromagnetic radiation generated by high-voltage lines decreases proportionally to the distance from the lines. The buildings can to some extent shield (or absorb) the electric fields generated by high-voltage lines nearby. The electromagnetic radiation intensity near high-voltage lines may be mitigated or intensified by the manner in which the high-voltage lines are set up, and it merits attention for the potential impact on human health.

  16. High-Capacity Cathode Material with High Voltage for Li-Ion Batteries.

    Science.gov (United States)

    Shi, Ji-Lei; Xiao, Dong-Dong; Ge, Mingyuan; Yu, Xiqian; Chu, Yong; Huang, Xiaojing; Zhang, Xu-Dong; Yin, Ya-Xia; Yang, Xiao-Qing; Guo, Yu-Guo; Gu, Lin; Wan, Li-Jun

    2018-01-15

    Electrochemical energy storage devices with a high energy density are an important technology in modern society, especially for electric vehicles. The most effective approach to improve the energy density of batteries is to search for high-capacity electrode materials. According to the concept of energy quality, a high-voltage battery delivers a highly useful energy, thus providing a new insight to improve energy density. Based on this concept, a novel and successful strategy to increase the energy density and energy quality by increasing the discharge voltage of cathode materials and preserving high capacity is proposed. The proposal is realized in high-capacity Li-rich cathode materials. The average discharge voltage is increased from 3.5 to 3.8 V by increasing the nickel content and applying a simple after-treatment, and the specific energy is improved from 912 to 1033 Wh kg-1 . The current work provides an insightful universal principle for developing, designing, and screening electrode materials for high energy density and energy quality. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Electronics drivers for high voltage dielectric electro active polymer (DEAP) applications

    DEFF Research Database (Denmark)

    Zhang, Zhe; Andersen, Michael A. E.

    2015-01-01

    Dielectric electro active polymer (DEAP) can be used in actuation, sensing and energy harvesting applications, but driving the DEAP based actuators and generators has three main challenges from a power electronics standpoint, i.e. high voltage ( around 2.5 kV), nonlinearity, and capacitive behavior...... magnetic and piezoelectric transformers are employed for the heating valve and incremental motor application, where only ON/OFF regulation is adopted fo r energy saving; as for DEAP based energy harvesting, the no - isolated Buck/Boost converter is used, due to the system high power capacity (above 100W......, because of its high control linearity, is implemented for the loud speaker application s . A synthesis among those converter topologies and control techniques is given; therefore, for those DEAP based applications, their diversity and similarity of electronics drivers, as well as the key technologies...

  18. Very low power, high voltage base for a Photo Multiplier Tube for the KM3NeT deep sea neutrino telescope

    CERN Document Server

    Timmer, P; Peek, H

    2010-01-01

    The described system is developed in the framework of a deep-sea submerged Very Large Volume neutrino Telescope where photons are detected by a large number of Photo Multiplier Tubes. These PMTs are placed in optical modules (OM). A basic Cockcroft-Walton (CW) voltage multiplier circuit design is used to generate multiple voltages to drive the dynodes of the photomultiplier tube. To achieve a long lifetime and a high reliability the dissipation in the OM must be kept to the minimum. The design is also constrained by size restrictions, load current, voltage range, and the maximum allowable ripple in the output voltage. A surface mount PMT-base PCB prototype is designed and successfully tested. The system draws less than 1.5 mA of supply current at a voltage of 3.3 V with outputs up to -1400 Vdc cathode voltage, a factor 10 less than the commercially available state of the art

  19. A high-voltage test for the ATLAS RPC qualification

    CERN Document Server

    Aielli, G; Cardarelli, R; Di Ciaccio, A; Di Simone, A; Liberti, B; Santonico, R

    2004-01-01

    The RPC production sequence for the ATLAS experiment includes a specific test of current absorption at the operating point, which concerns the RPC "gas volumes", namely the bare detectors not yet assembled with the read-out panels and the mechanical support structures. The test, which is carried out at the production site, consists of two phases. The gas volumes are initially conditioned with pure argon, keeping the voltage constant just above the breakdown value of about 2 kV. The final test, performed after the volumes have undergone inner surface varnishing with linseed oil, is based on the measurement of the current-voltage characteristics with the binary operating gas, C//2H//2F//4/i-C//4H//1//0 = 95/5. The results presented here concern 45% of the total foreseen production.

  20. Design of High-Voltage Switch-Mode Power Amplifier Based on Digital-Controlled Hybrid Multilevel Converter

    Directory of Open Access Journals (Sweden)

    Yanbin Hou

    2016-01-01

    Full Text Available Compared with conventional Class-A, Class-B, and Class-AB amplifiers, Class-D amplifier, also known as switching amplifier, employs pulse width modulation (PWM technology and solid-state switching devices, capable of achieving much higher efficiency. However, PWM-based switching amplifier is usually designed for low-voltage application, offering a maximum output voltage of several hundred Volts. Therefore, a step-up transformer is indispensably adopted in PWM-based Class-D amplifier to produce high-voltage output. In this paper, a switching amplifier without step-up transformer is developed based on digital pulse step modulation (PSM and hybrid multilevel converter. Under the control of input signal, cascaded power converters with separate DC sources operate in PSM switch mode to directly generate high-voltage and high-power output. The relevant topological structure, operating principle, and design scheme are introduced. Finally, a prototype system is built, which can provide power up to 1400 Watts and peak voltage up to ±1700 Volts. And the performance, including efficiency, linearity, and distortion, is evaluated by experimental tests.

  1. Effect of high-voltage impulse current on the structure and function of rabbit heart

    Directory of Open Access Journals (Sweden)

    Xin-ping XU

    2011-06-01

    Full Text Available Objective To explore the effect of high-voltage impulse current(HVIC on the structure and function of rabbit heart.Methods Sixty healthy male rabbits were involved in present study and divided into 6 groups randomly(n=10.The rabbits were then shocked using a high-voltage pulse generator with current intensity of 0,50,100,150,250 and 500mA(pulse width 100μs,duration 5s respectively.The heart rate and electrocardiogram(ECG of rabbits were detected before and 0,1,3,7,14 and 28 days after the electric shock.Moreover,the myocardial tissue of rabbits was obtained immediately and 28 days after shock to observe the pathological changes.Results Immediately after electric shock of 50 to 500mA,the heart rate of rabbit increased by different degree,and the ECG showed arrhythmia,myocardial ischemia,atrial fibrillation and atrioventricular block,and the changes recovered gradually one day later.The pathological observation showed cell swelling,separation of myofibril and sarcoplasmic condensation of Purkinje fibers immediately after electric shock of 50 to 500mA,and the changes recovered 28 days after shock.The cardiac injuries aggravated with the increasing of current intensity,especially when it exceeded 150mA,and the recovery time prolonged.Conclusion High-voltage impulse current may induce recoverable injuries on heart structure and function,and the damage effect shows a correlation with the current intensity.

  2. Design of a pulsewidth-modulated resonant converter for a high-output-voltage power supply

    Science.gov (United States)

    Turnbull, Fred G.; Tompkins, Russell E.

    1987-12-01

    The design and fabrication of a parallel resonant converter circuit and a high-frequency step-up transformer used to supply an adjustable dc voltage to a load is described. The 500-W system is operated from 115/230 V single-phase 60Hz power, which is rectified and filtered to form a 310-V dc link. A two-transistor half-bridge circuit operating at a fixed frequency above the ciruits resonant frequency converts the dc voltage to an ac voltage at approximately 20 kHx. This high-frequency voltage is transformed with a low-capacitance oil-impregnated ferrite transformer. The output voltage is rectified to form a dc voltage with a maximum value of 90-kV peak. The output voltage is adjustable using pulsewidth modulation of the conduction time of the two transistors in the power circuit. The energy stored in the resonant circuit provides a sinusoidal transformer voltage at fixed frequency over a wide range of control. The system is provided with a closed-loop peak-voltage regulator and an on-off capability from the control electronics. The transformer is designed for a specific value of inductance and capacitance to operate at the desired resonant frequency and characteristic impedance.

  3. Evaluation of high-voltage, high-power, solid-state remote power controllers for amps

    Science.gov (United States)

    Callis, Charles P.

    1987-01-01

    The Electrical Power Branch at Marshall Space Flight Center has a Power System Development Facility where various power circuit breadboards are tested and evaluated. This project relates to the evaluation of a particular remote power controller (RPC) energizing high power loads. The Facility equipment permits the thorough testing and evaluation of high-voltage, high-power solid-state remote power controllers. The purpose is to evaluate a Type E, 30 Ampere, 200 V dc remote power controller. Three phases of the RPC evaluation are presented. The RPC is evaluated within a low-voltage, low-power circuit to check its operational capability. The RPC is then evaluated while performing switch/circuit breaker functions within a 200 V dc, 30 Ampere power circuit. The final effort of the project relates to the recommended procedures for installing these RPC's into the existing Autonomously Managed Power System (AMPS) breadboard/test facility at MSFC.

  4. High Input Voltage Discharge Supply for High Power Hall Thrusters Using Silicon Carbide Devices

    Science.gov (United States)

    Pinero, Luis R.; Scheidegger, Robert J.; Aulsio, Michael V.; Birchenough, Arthur G.

    2014-01-01

    A power processing unit for a 15 kW Hall thruster is under development at NASA Glenn Research Center. The unit produces up to 400 VDC with two parallel 7.5 kW discharge modules that operate from a 300 VDC nominal input voltage. Silicon carbide MOSFETs and diodes were used in this design because they were the best choice to handle the high voltage stress while delivering high efficiency and low specific mass. Efficiencies in excess of 97 percent were demonstrated during integration testing with the NASA-300M 20 kW Hall thruster. Electromagnet, cathode keeper, and heater supplies were also developed and will be integrated with the discharge supply into a vacuum-rated brassboard power processing unit with full flight functionality. This design could be evolved into a flight unit for future missions that requires high power electric propulsion.

  5. Topics in high voltage pulsed power plasma devices and applications

    Science.gov (United States)

    Chen, Hao

    Pulsed power technology is one of the tools that is used by scientists and engineers nowadays to produce gas plasmas. The transient ultra high power is able to provide a huge pulse of energy which is sometimes greater than the ionization energy of the gas, and therefore separates the ions and electrons to form the plasma. Sometimes, the pulsed power components themselves are plasma devices. For example, the gas type switches can "turn on" the circuit by creating the plasma channel between the switch electrodes. Mini Back Lighted Thyratron, or as we call it, mini-BLT, is one of these gas type plasma switches. The development of the reduced size and weight "mini-BLT" is presented in this dissertation. Based on the operation characteristics testing of the mini-BLT, suggestions of optimizing the design of the switch are proposed. All the factors such as the geometry of the hollow electrodes and switch housing, the gas condition, the optical triggering source, etc. are necessary to consider when we design and operate the mini-BLT. By reducing the diameter of the cylindrical gas path between the electrodes in the BLT, a novel high density plasma source is developed, producing the plasma in the "squeezed" capillary. The pulsed power generator, of course, is inevitably used to provide the ionization energy for hydrogen gas sealed in the capillary. Plasma diagnostics are necessarily analyzed and presented in detail to properly complete and understand the capillary plasma. This high density plasma source (1019 cm-3) has the potential applications in the plasma wakefield accelerator. The resonant oscillation behavior of the particles in plasmas allows for dynamically generated accelerating electric fields that have orders of magnitude larger than those available in the conventional RF accelerators. Finally, the solid state switches are introduced as a comparison to the gas type switch. Pulsed power circuit topologies such as the Marx Bank, magnetic pulse compression and diode

  6. Charge-pump voltage converter

    Science.gov (United States)

    Brainard, John P [Albuquerque, NM; Christenson, Todd R [Albuquerque, NM

    2009-11-03

    A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

  7. Serially-Connected Compensator for Eliminating the Unbalanced Three-Phase Voltage Impact on Wind Turbine Generators: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Z.; Hsu, P.; Muljadi, E.; Gao, W.

    2015-04-06

    Untransposed transmission lines, unbalanced tap changer operations, and unbalanced loading in weak distribution lines can cause unbalanced-voltage conditions. The resulting unbalanced voltage at the point of interconnection affects proper gird integration and reduces the lifetime of wind turbines due to power oscillations, torque pulsations, mechanical stresses, energy losses, and uneven and overheating of the generator stator winding. This work investigates the dynamic impact of unbalanced voltage on the mechanical and electrical components of integrated Fatigue, Aerodynamics, Structures, and Turbulence (FAST) wind turbine generation systems (WTGs) of Type 1 (squirrel-cage induction generator) and Type 3 (doubly-fed induction generator). To alleviate this impact, a serially-connected compensator for a three-phase power line is proposed to balance the wind turbine-side voltage. Dynamic simulation studies are conducted in MATLAB/Simulink to compare the responses of these two types of wind turbine models under normal and unbalanced-voltage operation conditions and demonstrate the effectiveness of the proposed compensator.

  8. Response of low voltage networks with high penetration of photovoltaic systems to transmission network faults

    NARCIS (Netherlands)

    Skaloumpakas, K.; Boemer, J.C.; Van Ruitenbeek, E.; Gibescu, M.

    2014-01-01

    The installed capacity of photovoltaic (PV) systems connected to low voltage (LV) networks in Germany has increased to more than 25 GW. Current grid codes still mandate these PV systems to disconnect in case of voltage dips below 0.8 p.u. The resulting response of LV distribution systems with high

  9. High performance AC–DC control power supply for low voltage ride ...

    Indian Academy of Sciences (India)

    Home; Journals; Sadhana; Volume 41; Issue 2 ... The CPS design presented here maintains a constant 24Vdc output even over a wide (90Vrms to 270Vrms ) ac voltage variation at its input for a High Power Converter (HPC). ... The CPS was tested for wide input voltage range (vin) and the performance validates the design.

  10. High voltage conversion ratio, switched C & L cells, step-down DC-DC converter

    DEFF Research Database (Denmark)

    Pelan, Ovidiu; Muntean, Nicolae; Cornea, Octavian

    2013-01-01

    The paper presents a high voltage conversion ratio DC-DC step-down topology obtained from a classical buck converter associated with an input switched-capacitor cell and an output switched-inductor cell. Analytical descriptions, the voltage and current limits of the main components are synthesize...

  11. Nonlinear Parasitic Capacitance Modelling of High Voltage Power MOSFETs in Partial SOI Process

    DEFF Research Database (Denmark)

    Fan, Lin; Knott, Arnold; Jørgensen, Ivan Harald Holger

    2016-01-01

    : off-state, sub-threshold region, and on-state in the linear region. A high voltage power MOSFET is designed in a partial Silicon on Insulator (SOI) process, with the bulk as a separate terminal. 3D plots and contour plots of the capacitances versus bias voltages for the transistor summarize...

  12. High level white noise generator

    Science.gov (United States)

    Borkowski, Casimer J.; Blalock, Theron V.

    1979-01-01

    A wide band, stable, random noise source with a high and well-defined output power spectral density is provided which may be used for accurate calibration of Johnson Noise Power Thermometers (JNPT) and other applications requiring a stable, wide band, well-defined noise power spectral density. The noise source is based on the fact that the open-circuit thermal noise voltage of a feedback resistor, connecting the output to the input of a special inverting amplifier, is available at the amplifier output from an equivalent low output impedance caused by the feedback mechanism. The noise power spectral density level at the noise source output is equivalent to the density of the open-circuit thermal noise or a 100 ohm resistor at a temperature of approximately 64,000 Kelvins. The noise source has an output power spectral density that is flat to within 0.1% (0.0043 db) in the frequency range of from 1 KHz to 100 KHz which brackets typical passbands of the signal-processing channels of JNPT's. Two embodiments, one of higher accuracy that is suitable for use as a standards instrument and another that is particularly adapted for ambient temperature operation, are illustrated in this application.

  13. Fundamentals of high energy electron beam generation

    Science.gov (United States)

    Turman, B. N.; Mazarakis, M. G.; Neau, E. L.

    High energy electron beam accelerator technology has been developed over the past three decades in response to military and energy-related requirements for weapons simulators, directed-energy weapons, and inertially-confined fusion. These applications required high instantaneous power, large beam energy, high accelerated particle energy, and high current. These accelerators are generally referred to as 'pulsed power' devices, and are typified by accelerating potential of millions of volts (MV), beam current in thousands of amperes (KA), pulse duration of tens to hundreds of nanoseconds, kilojoules of beam energy, and instantaneous power of gigawatts to teffawatts (10(exp 9) to 10(exp 12) watts). Much of the early development work was directed toward single pulse machines, but recent work has extended these pulsed power devices to continuously repetitive applications. These relativistic beams penetrate deeply into materials, with stopping range on the order of a centimeter. Such high instantaneous power deposited in depth offers possibilities for new material fabrication and processing capabilities that can only now be explored. Fundamental techniques of pulse compression, high voltage requirements, beam generation and transport under space-charge-dominated conditions will be discussed in this paper.

  14. The effect of high voltage, high frequency pulsed electric field on slain ovine cortical bone.

    Science.gov (United States)

    Asgarifar, Hajarossadat; Oloyede, Adekunle; Zare, Firuz

    2014-04-01

    High power, high frequency pulsed electric fields known as pulsed power (PP) has been applied recently in biology and medicine. However, little attention has been paid to investigate the application of pulse power in musculoskeletal system and its possible effect on functional behavior and biomechanical properties of bone tissue. This paper presents the first research investigating whether or not PP can be applied safely on bone tissue as a stimuli and what will be the possible effect of these signals on the characteristics of cortical bone by comparing the mechanical properties of this type of bone pre and post expose to PP and in comparison with the control samples. A positive buck-boost converter was applied to generate adjustable high voltage, high frequency pulses (up to 500 V and 10 kHz). The functional behavior of bone in response to pulse power excitation was elucidated by applying compressive loading until failure. The stiffness, failure stress (strength) and the total fracture energy (bone toughness) were determined as a measure of the main bone characteristics. Furthermore, an ultrasonic technique was applied to determine and comprise bone elasticity before and after pulse power stimulation. The elastic property of cortical bone samples appeared to remain unchanged following exposure to pulse power excitation for all three orthogonal directions obtained from ultrasonic technique and similarly from the compression test. Nevertheless, the compressive strength and toughness of bone samples were increased when they were exposed to 66 h of high power pulsed electromagnetic field compared to the control samples. As the toughness and the strength of the cortical bone tissue are directly associated with the quality and integrity of the collagen matrix whereas its stiffness is primarily related to bone mineral content these overall results may address that although, the pulse power stimulation can influence the arrangement or the quality of the collagen network

  15. Improved rotor current control of wind turbine driven doubly-fed induction generators during network voltage unbalance

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jiabing; He, Yikang [College of Electrical Engineering, Zhejiang University, Hangzhou 310027 (China); Xu, Lie [School of Electronic, Electrical Engineering and Computer Science, The Queen' s University of Belfast, Belfast BT9 5AH (United Kingdom)

    2010-07-15

    This paper investigates an improved control and operation of a doubly-fed induction generator (DFIG) system under unbalanced network conditions. A new rotor current control scheme is presented, which consists of a main controller and an auxiliary compensator. The main controller is constructed in the same way as the conventional vector control design without involving sequential-component decomposition in order to guarantee system stability and high transient response. While the auxiliary controller is specially designed to control the negative sequence current taking into account the impact of the main controller on negative sequence components. Simulated results on a commercial 1.5-MW DFIG system and experimental tests on a 1.5-kW DFIG prototype are provided and compared with those of conventional vector control and dual PI current control schemes to demonstrate the effectiveness of the proposed control strategy during steady-state and transient conditions when the network voltage is unbalanced. (author)

  16. Locational Pricing to Mitigate Voltage Problems Caused by High PV Penetration

    OpenAIRE

    Sam Weckx; Reinhilde D'hulst; Johan Driesen

    2015-01-01

    In this paper, a locational marginal pricing algorithm is proposed to control the voltage in unbalanced distribution grids. The increasing amount of photovoltaic (PV) generation installed in the grid may cause the voltage to rise to unacceptable levels during periods of low consumption. With locational prices, the distribution system operator can steer the reactive power consumption and active power curtailment of PV panels to guarantee a safe network operation. Flexible loads also respond to...

  17. High Performance, Low Operating Voltage n-Type Organic Field Effect Transistor Based on Inorganic-Organic Bilayer Dielectric System

    Science.gov (United States)

    Dey, A.; Singh, A.; Kalita, A.; Das, D.; Iyer, P. K.

    2016-04-01

    The performance of organic field-effect transistors (OFETs) fabricated utilizing vacuum deposited n-type conjugated molecule N,N’-Dioctadecyl-1,4,5,8-naphthalenetetracarboxylic diimide (NDIOD2) were investigated using single and bilayer dielectric system over a low-cost glass substrate. Single layer device structure consists of Poly (vinyl alcohol) (PVA) as the dielectric material whereas the bilayer systems contain two different device configuration namely aluminum oxide/Poly (vinyl alcohol) (Al2O3/PVA) and aluminum oxide/Poly (methyl mefhacrylate) (Al2O3/PMMA) in order to reduce the operating voltage and improve the device performance. It was observed that the devices with Al2O3/PMMA bilayer dielectric system and top contact aluminum electrodes exhibit excellent n-channel behaviour under vacuum compared to the other two structures with electron mobility value of 0.32 cm2/Vs, threshold voltages ~1.8 V and current on/off ratio ~104, operating under a very low voltage (6 V). These devices demonstrate highly stable electrical behaviour under multiple scans and low threshold voltage instability in vacuum condition even after 7 days than the Al2O3/PVA device structure. This low operating voltage, high performance OTFT device with bilayer dielectric system is expected to have diverse applications in the next generation of OTFT technologies.

  18. Comparative analysis of cellulose pressboard and aramid paper used in air insulation systems of high-voltage devices

    Directory of Open Access Journals (Sweden)

    Turba Tomasz

    2017-01-01

    Full Text Available The paper presents results of a comparative analysis of parameters of two kinds of solid dielectrics used in air insulation systems to prevent occurring partial discharges. The research works regarded materials made of: cellulose pressboard and aramid paper. All measurements were performed under laboratory conditions by changing the value of partial discharges generation voltage until breakdown occurred in the inhomogeneous environment that was simulated using needle-plate (made of copper electrode system. The main contribution which resulted from studies is a statement that potential use of aramid paper as a dielectric can extend the life of a high voltage electric device as compared to standard cellulose pressboard usage due to higher electric resistances to breakdown or detection of corona voltage. Results shown that the aramid paper has greater electric resistance to breakdown in comparison to cellulose with no difference between both on detecting corona of partial discharge.

  19. Comparative analysis of cellulose pressboard and aramid paper used in air insulation systems of high-voltage devices

    Science.gov (United States)

    Turba, Tomasz; Frącz, Paweł

    2017-10-01

    The paper presents results of a comparative analysis of parameters of two kinds of solid dielectrics used in air insulation systems to prevent occurring partial discharges. The research works regarded materials made of: cellulose pressboard and aramid paper. All measurements were performed under laboratory conditions by changing the value of partial discharges generation voltage until breakdown occurred in the inhomogeneous environment that was simulated using needle-plate (made of copper) electrode system. The main contribution which resulted from studies is a statement that potential use of aramid paper as a dielectric can extend the life of a high voltage electric device as compared to standard cellulose pressboard usage due to higher electric resistances to breakdown or detection of corona voltage. Results shown that the aramid paper has greater electric resistance to breakdown in comparison to cellulose with no difference between both on detecting corona of partial discharge.

  20. Efficient Parametric Identification Method for High Voltage Pulse Transformers

    CERN Document Server

    Aguglia, D; Viarouge, P; Cros, J

    2014-01-01

    This paper presents a new identification method for a pulse transformer equivalent circuit. It is based on an analytical approximation of the frequency-domain impedance data derived from a no-load test with open-circuited secondary winding and only requires measurements of primary current and voltage without phase data. Compared with time consuming and complex methods based on off-line non-linear identification procedures, this simple method also gives an estimation of the error on the identified parameters. The method is validated on an existing pulse transformer.

  1. Effect of recovery time of fault current limiter on over current from distributed generator in micro grid after voltage sag

    Directory of Open Access Journals (Sweden)

    Daisuke Iioka

    2016-01-01

    Full Text Available This paper describes an effect of recovery time of fault current limiter on over current from a micro grid system which is interconnected to a power distribution system. We have assumed that the semi-conductor type fault current limiter is installed between the micro grid system with the synchronous generator and the power distribution system, measured the over current after a voltage sag occurrence in the power distribution system and a recovery of fault current limiter by experiments in our laboratory. Finally, it was found that the introduction of recovery time for fault current limiter after voltage sag is useful for suppressing the over current from the distributed generator.

  2. Understanding and Prevention of Transient Voltages and Dielectric Breakdown in High Voltage Battery Systems

    Science.gov (United States)

    2017-07-31

    other provision of law , no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a...in high current battery systems and how vented Li-ion electrolyte gas impacts the dielectric breakdown strength of ambient air. 1S. SUBJECTTERMS...electrical grid, either in homes or in the distribution network, but the loads being sourced in those applications are vastly different than those being

  3. Multifunctional pulse generator for high-intensity focused ultrasound system

    Science.gov (United States)

    Tamano, Satoshi; Yoshizawa, Shin; Umemura, Shin-Ichiro

    2017-07-01

    High-intensity focused ultrasound (HIFU) can achieve high spatial resolution for the treatment of diseases. A major technical challenge in implementing a HIFU therapeutic system is to generate high-voltage high-current signals for effectively exciting a multichannel HIFU transducer at high efficiencies. In this paper, we present the development of a multifunctional multichannel generator/driver. The generator can produce a long burst as well as an extremely high-voltage short pulse of pseudosinusoidal waves (trigger HIFU) and second-harmonic superimposed waves for HIFU transmission. The transmission timing, waveform, and frequency can be controlled using a field-programmable gate array (FPGA) via a universal serial bus (USB) microcontroller. The hardware is implemented in a compact printed circuit board. The test results of trigger HIFU reveal that the power consumption and the temperature rise of metal-oxide semiconductor field-effect transistors were reduced by 19.9% and 38.2 °C, respectively, from the previous design. The highly flexible performance of the novel generator/driver is demonstrated in the generation of second-harmonic superimposed waves, which is useful for cavitation-enhanced HIFU treatment, although the previous design exhibited difficulty in generating it.

  4. Analysis of Wind Generator Operations under Unbalanced Voltage Dips in the Light of the Spanish Grid Code

    Directory of Open Access Journals (Sweden)

    Joaquín Montañana-Romeu

    2011-08-01

    Full Text Available Operation of doubly fed induction generators subjected to transient unbalanced voltage dips is analyzed in this article to verify the fulfillment of the Spanish grid code. Akagi’s p-q theory is not used for this study, because control of the electronic converter is not the main goal of the paper, but rather to know the physical phenomena involved in the wind turbine when voltage dips occur. Hence, the magnetizing reactive power of the induction generators and their components, which are related with the magnetic fields and determine operation of these machines, are expressed through the reactive power formulations established in the technical literature by three well-known approaches: the delayed voltage (DV method, Czarnecki’s Current’s Physical Components (CPC theory and Emanuel’s approach. Non-fundamental and negative-sequence components of the magnetizing reactive power are respectively established to define the effects of the distortion and voltage imbalances on the magnetic fields and electromagnetic torques. Also, fundamental-frequency positive-sequence and negative-sequence reactive powers are decomposed into two components: due to the reactive loads and caused by the imbalances. This decomposition provides additional information about the effects of the imbalances on the main magnetic field and electromagnetic torque of the induction generator. All the above mentioned reactive powers are finally applied to one actual wind turbine subjected to a two-phase voltage dip in order to explain its operation under such transient conditions.

  5. Results of the 2015 testbeam of a 180 nm AMS High-Voltage CMOS sensor prototype

    CERN Document Server

    Benoit, M.

    2016-07-21

    Active pixel sensors based on the High-Voltage CMOS technology are being investigated as a viable option for the future pixel tracker of the ATLAS experiment at the High-Luminosity LHC. This paper reports on the testbeam measurements performed at the H8 beamline of the CERN Super Proton Synchrotron on a High-Voltage CMOS sensor prototype produced in 180 nm AMS technology. Results in terms of tracking efficiency and timing performance, for different threshold and bias conditions, are shown.

  6. Diffusion voltage in polymer light emitting diodes measured with electric field induced second harmonic generation

    Energy Technology Data Exchange (ETDEWEB)

    Kristensen, P.K.; Rafaelsen, J.; Pedersen, T.G.; Pedersen, K. [Department of Physics and Nanotechnology, Aalborg University, Pontoppidanstraede 103, 9220 Aalborg East (Denmark)

    2005-12-01

    We apply electric field induced second harmonic (EFISH) to polymer light emitting diodes (PLEDs) and demonstrate the ability to determine the diffusion voltage in PLED devices. The EFISH signal is proportional to the square of the effective field, which is the sum of the diffusion voltage and the applied voltage. By minimizing the EFISH-signal as a function of the applied voltage, the diffusion voltage is determined by measuring the applied voltage that cancels out the diffusion voltage. The PLEDs are fabricated with indium tin oxide (ITO) as the hole injecting contact and two different electron injecting contacts, namely aluminum and calcium. The diffusion voltage originates from the rearranged charges caused by the difference in Fermi levels in the materials in the PLEDs. Different contacts will thus cause different diffusion voltages. We demonstrate here that the EFISH signal is proportional to the square of the effective field in both reverse and forward bias, and discuss the dependence on contact materials. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  7. Calculation and measurement of a neutral air flow velocity impacting a high voltage capacitor with asymmetrical electrodes

    Directory of Open Access Journals (Sweden)

    M. Malík

    2014-01-01

    Full Text Available This paper deals with the effects surrounding phenomenon of a mechanical force generated on a high voltage asymmetrical capacitor (the so called Biefeld-Brown effect. A method to measure this force is described and a formula to calculate its value is also given. Based on this the authors derive a formula characterising the neutral air flow velocity impacting an asymmetrical capacitor connected to high voltage. This air flow under normal circumstances lessens the generated force. In the following part this velocity is measured using Particle Image Velocimetry measuring technique and the results of the theoretically calculated velocity and the experimentally measured value are compared. The authors found a good agreement between the results of both approaches.

  8. Preparation methodology and possible treatments for improved ceramics for high voltage vacuum applications

    CERN Document Server

    Tan, J

    1998-01-01

    The flashover characteristics of an insulator bridged high voltage vacuum gap can play an important role in the overall performance of a high voltage device, for example in the extreme environments of high energy particle accelerators. The detailed preparation of the insulators is, at present, governed by the commercial production methods and by standard bulk cleaning processes, which for a particular application may be far from optimum. The influence of the mechanical preparation, thermal history and particular cleaning technique have been investigated for commercially available alumina samples, with measurement of surface characteristics by scanning electron microscopy and laser diffraction, measurement of the secondary electron emission curve and analysis of the high voltage performance with the possibility of applied fields up to 200kV/cm. The results of the different measurements are discussed in the overall context of the problems encountered in the full sized high voltage devices, and suggestions are m...

  9. Dynamic Stability Improvement of Grid Connected DFIG Using Enhanced Field Oriented Control Technique for High Voltage Ride Through

    Directory of Open Access Journals (Sweden)

    V. N. Ananth Duggirala

    2015-01-01

    Full Text Available Doubly fed induction generator (DFIG is a better alternative to increased power demand. Modern grid regulations force DFIG to operate without losing synchronism during overvoltages called high voltage ride through (HVRT during grid faults. Enhanced field oriented control technique (EFOC was proposed in Rotor Side Control of DFIG converter to improve power flow transfer and to improve dynamic and transient stability. Further electromagnetic oscillations are damped, improved voltage mitigation and limit surge currents for sustained operation of DFIG during voltage swells. The proposed strategy has advantages such as improved reactive power control, better damping of electromagnetic torque oscillations, and improved continuity of voltage and current from stator and rotor to grid during disturbance. In EFOC technique, rotor flux reference changes its value from synchronous speed to zero during fault for injecting current at the rotor slip frequency. In this process, DC-Offset component of stator flux is controlled so that decomposition during overvoltage faults can be minimized. The offset decomposition of flux will be oscillatory in a conventional FOC, whereas in EFOC it is aimed to be quick damping. The system performance with overvoltage of 1.3 times, 1.62 times, and 2 times the rated voltage occurring is analyzed by using simulation studies.

  10. Improved modeling of new three-phase high voltage transformer with magnetic shunts

    Directory of Open Access Journals (Sweden)

    Chraygane M.

    2015-03-01

    Full Text Available This original paper deals with a new approach for the study of behavior in nonlinear regime of a new three-phase high voltage power supply for magnetrons, used for the microwave generators in industrial applications. The design of this system is composed of a new three-phase leakage flux transformer supplying by phase a cell, composed of a capacitor and a diode, which multiplies the voltage and stabilizes the current. Each cell. in turn, supplies a single magnetron. An equivalent model of this transformer is developed taking into account the saturation phenomenon and the stabilization process of each magnetron. Each inductance of the model is characterized by a non linear relation between flux and current. This model was tested by EMTP software near the nominal state. The theoretical results were compared to experimental measurements with a good agreement. Relative to the current device, the new systemprovides gains of size, volume, cost of implementation and maintenance which make it more economical.

  11. Environmental justice: a contrary finding for the case of high-voltage electric power transmission lines.

    Science.gov (United States)

    Wartenberg, Daniel; Greenberg, Michael R; Harris, Gerald

    2010-05-01

    Environmental justice is the consideration of whether minority and/or lower-income residents in a geographic area are likely to have disproportionately higher exposures to environmental toxins than those living elsewhere. Such situations have been identified for a variety of factors, such as air pollution, hazardous waste, water quality, noise, residential crowding, and housing quality. This study investigates the application of this concept to high-voltage electric power transmission lines (HVTL), which some perceive as a health risk because of the magnetic fields they generate, and also as esthetically unpleasing. We mapped all 345 kV and higher voltage HVTL in New York State and extracted and summarized proximate US Census sociodemographic and housing characteristic data into four categories on the basis of distances from HVTL. Contrary to our expectation, people living within 2000 ft from HVTL were more likely to be exposed to magnetic fields, white, of higher income, more educated and home owners, than those living farther away, particularly in urban areas. Possible explanations for these patterns include the desire for the open space created by the rights-of-way, the preference for new homes/subdivisions that are often located near HVTL, and moving closer to HVTL before EMFs were considered a risk. This study suggests that environmental justice may not apply to all environmental risk factors and that one must be cautious in generalizing. In addition, it shows the utility of geographical information system methodology for summarizing information from extremely large populations, often a challenge in epidemiology.

  12. Temporal and voltage stress stability of high performance indium-zinc-oxide thin film transistors

    Science.gov (United States)

    Song, Yang; Katsman, Alexander; Butcher, Amy L.; Paine, David C.; Zaslavsky, Alexander

    2017-10-01

    Thin film transistors (TFTs) based on transparent oxide semiconductors, such as indium zinc oxide (IZO), are of interest due to their improved characteristics compared to traditional a-Si TFTs. Previously, we reported on top-gated IZO TFTs with an in-situ formed HfO2 gate insulator and IZO active channel, showing high performance: on/off ratio of ∼107, threshold voltage VT near zero, extracted low-field mobility μ0 = 95 cm2/V·s, and near-perfect subthreshold slope at 62 mV/decade. Since device stability is essential for technological applications, in this paper we report on the temporal and voltage stress stability of IZO TFTs. Our devices exhibit a small negative VT shift as they age, consistent with an increasing carrier density resulting from an increasing oxygen vacancy concentration in the channel. Under gate bias stress, freshly annealed TFTs show a negative VT shift during negative VG gate bias stress, while aged (>1 week) TFTs show a positive VT shift during negative VG stress. This indicates two competing mechanisms, which we identify as the field-enhanced generation of oxygen vacancies and the field-assisted migration of oxygen vacancies, respectively. A simplified kinetic model of the vacancy concentration evolution in the IZO channel under electrical stress is provided.

  13. An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.

    Energy Technology Data Exchange (ETDEWEB)

    Litzenberger, Wayne; Lava, Val

    1994-08-01

    References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

  14. Efficiency Optimization by Considering the High Voltage Flyback Transformer Parasitics using an Automatic Winding Layout Technique

    DEFF Research Database (Denmark)

    Thummala, Prasanth; Schneider, Henrik; Zhang, Zhe

    2015-01-01

    .The energy efficiency is optimized using a proposed new automatic winding layout (AWL) technique and a comprehensive loss model.The AWL technique generates a large number of transformer winding layouts.The transformer parasitics such as dc resistance, leakage inductance and self-capacitance are calculated...... for each winding layout.An optimization technique is formulated to minimize the sum of energy losses during charge and discharge operations.The efficiency and energy loss distribution results from the optimization routine provide a deep insight into the high voltage transformer designand its impact...... on the total converter efficiency.The proposed efficiency optimization approach is experimentally verified on a25 W (average charging power) with100 W (peakpower) flyback dc-dc prototype....

  15. The Design of Integrated Information System for High Voltage Metering Lab

    Science.gov (United States)

    Ma, Yan; Yang, Yi; Xu, Guangke; Gu, Chao; Zou, Lida; Yang, Feng

    2018-01-01

    With the development of smart grid, intelligent and informatization management of high-voltage metering lab become increasingly urgent. In the paper we design an integrated information system, which automates the whole transactions from accepting instruments, make experiments, generating report, report signature to instrument claims. Through creating database for all the calibrated instruments, using two-dimensional code, integrating report templates in advance, establishing bookmarks and online transmission of electronical signatures, our manual procedures reduce largely. These techniques simplify the complex process of account management and report transmission. After more than a year of operation, our work efficiency improves about forty percent averagely, and its accuracy rate and data reliability are much higher as well.

  16. Ionization processes in combined high-voltage nanosecond - laser discharges in inert gas

    Science.gov (United States)

    Starikovskiy, Andrey; Shneider, Mikhail; PU Team

    2016-09-01

    Remote control of plasmas induced by laser radiation in the atmosphere is one of the challenging issues of free space communication, long-distance energy transmission, remote sensing of the atmosphere, and standoff detection of trace gases and bio-threat species. Sequences of laser pulses, as demonstrated by an extensive earlier work, offer an advantageous tool providing access to the control of air-plasma dynamics and optical interactions. The avalanche ionization induced in a pre-ionized region by infrared laser pulses where investigated. Pre-ionization was created by an ionization wave, initiated by high-voltage nanosecond pulse. Then, behind the front of ionization wave extra avalanche ionization was initiated by the focused infrared laser pulse. The experiment was carried out in argon. It is shown that the gas pre-ionization inhibits the laser spark generation under low pressure conditions.

  17. Insulation co-ordination in high-voltage electric power systems

    CERN Document Server

    Diesendorf, W

    2015-01-01

    Insulation Co-ordination in High-Voltage Electric Power Systems deals with the methods of insulation needed in different circumstances. The book covers topics such as overvoltages and lightning surges; disruptive discharge and withstand voltages; self-restoring and non-self-restoring insulation; lightning overvoltages on transmission lines; and the attenuation and distortion of lightning surges. Also covered in the book are topics such as the switching surge designs of transmission lines, as well as the insulation coordination of high-voltage stations. The text is recommended for electrical en

  18. Bidirectional Flyback Converter with Multiple Series Connected Outputs for High Voltage Capacitive Charge and Discharge Applications

    DEFF Research Database (Denmark)

    Thummala, Prasanth; Schneider, Henrik; Zhang, Zhe

    2015-01-01

    V) in series with a high voltage blocking diode is added, in parallel with a high voltage freewheeling diode of a conventional flyback topology, to enable bidirectional operation. Experimental result from a digitally controlled bidirectional flyback converter shows that the discharge energy efficiency...... by lower voltage rating MOSFETs driven by a gate drive transformer. Simulation results to compare the operation of conventional and proposed converters are provided. The advantages of proposed implementation are improved energy efficiency and lower cost. Experimental results with two series connected...

  19. A Sepic-Type Single-Stage Electronic Ballast for High Line Voltage Applications

    Science.gov (United States)

    Shen, Chih-Lung; Chen, Kuo-Kuang

    In this paper, a sepic-type single-stage electronic ballast (STSSEB) is proposed, which is derived from the combination of a sepic converter and a half-bridge inverter. The ballast can not only step down input voltage directly but achieve high power factor, reduce voltage stress, improve efficiency and lower cost. Since component stress is reduced significantly, the presented ballast can be applied to high voltage mains. Derivation of the STSSEB is first presented. Then, analysis, design and practical consideration for the STSSEB are discussed. A 347Vac 60W prototype has been simulated and implemented. Simulations and experimental results have verified the feasibility of the proposed STSSEB.

  20. A high voltage gain quasi Z-source isolated DC/DC converter

    DEFF Research Database (Denmark)

    Siwakoti, Yam P.; Blaabjerg, Frede; Loh, Poh Chiang

    2014-01-01

    by a voltage doubling output rectifier. The converter is well-suited to applications requiring a high voltage gain, especially renewable energy sources such as photovoltaic and fuel-cell power supplies. To demonstrate the converter's performance a prototype designed to output 400 V at 500 W was constructed......A compact quasi-Z-source DC/DC converter is presented with high voltage gain, isolated output, and improved efficiency. The improvements in size and performance were achieved by using a square wave inverter with only two output switches driving an isolating transformer in push-pull mode, followed...

  1. A low knee voltage and high breakdown voltage of 4H-SiC TSBS employing poly-Si/Ni Schottky scheme

    Science.gov (United States)

    Kim, Dong Young; Seok, Ogyun; Park, Himchan; Bahng, Wook; Kim, Hyoung Woo; Park, Ki Cheol

    2018-02-01

    We report a low knee voltage and high breakdown voltage 4H-SiC TSBS employing poly-Si/Ni dual Schottky contacts. A knee voltage was significantly improved from 0.75 to 0.48 V by utilizing an alternative low work-function material of poly-Si as an anode electrode. Also, reverse breakdown voltage was successfully improved from 901 to 1154 V due to a shrunk low-work-function Schottky region by a proposed self-align etching process between poly-Si and SiC. SiC TSBS with poly-Si/Ni dual Schottky scheme is a suitable structure for high-efficiency rectification and high-voltage blocking operation.

  2. Coordination of voltage and reactive power control in the extra high voltage substations based on the example of solutions applied in the national power system

    Directory of Open Access Journals (Sweden)

    Dariusz Kołodziej

    2012-06-01

    Full Text Available This paper presents examples of coordination between automatic voltage and reactive power control systems (ARST covering adjacent and strongly related extra high voltage substations. Included are conclusions resulting from the use of these solutions. The Institute of Power Engineering, Gdańsk Division has developed and deployed ARST systems in the national power system for a dozen or so years.

  3. A high voltage, constant current stimulator for electrocutaneous stimulation through small electrodes.

    Science.gov (United States)

    Poletto, C J; Van Doren, C L

    1999-08-01

    A high-voltage stimulator has been designed to allow transcutaneous stimulation of tactile fibers of the fingertip. The stimulator's output stage was based upon an improved Howland current pump topology, modified to allow high load impedances and small currents. The compliance voltage of approximately 800 V is achieved using commercially available high-voltage operational amplifiers. The output current accuracy is better than +/- 5% over the range of 1 to 25 mA for 30 microseconds or longer pulses. The rise time for square pulses is less than 1 microsecond. High-voltage, common-mode, latch-up power supply problems and solutions are discussed. The stimulator's input stage is optically coupled to the controlling computer and complies with applicable safety standards for use in a hospital environment. The design presented here is for monophasic stimulation only, but could be modified for biphasic stimulation.

  4. Demonstration of the two-chamber approach for high-voltage measurements using collinear laser spectroscopy

    Science.gov (United States)

    Will, Elisa; Ullmann, Johannes; Frömmgen, Nadja; Geppert, Christopher; Gorges, Christian; Hammen, Michael; Kaufmann, Simon; Krieger, Andreas; Nörtershäuser, Wilfried

    2014-06-01

    An electronic measurement of high-voltages of several ten kV with accuracy as required for precision experiments is currently only feasible using highly sophisticated voltage dividers. Collinear laser spectroscopy can provide a direct and precise measurement of high-voltages using the Doppler shift of accelerated ions. Although proposed already in 1982, a measurement with relative accuracy better than 10-4 was not reported so far. To improve this accuracy, a dedicated new setup for high-voltage measurements will be installed at the Technische Universität Darmstadt. A two-chamber approach will be used to remove uncertainties due to the insufficiently known starting potential inside the ion source. Here we present a demonstration of the pump-and-probe technique performed in preparatory studies at the TRIGA-LASER experiment in Mainz.

  5. Project resumes: biological effects from electric fields associated with high-voltage transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-01-01

    Abstracts of research projects are presented in the following areas: measurements and special facilities; cellular and subcellular studies; physiology; behavior; environmental effects; modeling, scaling and dosimetry; and high voltage direct current. (ACR)

  6. Lithium-Ion Electrolytes with Improved Safety Tolerance to High Voltage Systems

    Science.gov (United States)

    Smart, Marshall C. (Inventor); Bugga, Ratnakumar V. (Inventor); Prakash, Surya G. (Inventor); Krause, Frederick C. (Inventor)

    2015-01-01

    The invention discloses various embodiments of electrolytes for use in lithium-ion batteries, the electrolytes having improved safety and the ability to operate with high capacity anodes and high voltage cathodes. In one embodiment there is provided an electrolyte for use in a lithium-ion battery comprising an anode and a high voltage cathode. The electrolyte has a mixture of a cyclic carbonate of ethylene carbonate (EC) or mono-fluoroethylene carbonate (FEC) co-solvent, ethyl methyl carbonate (EMC), a flame retardant additive, a lithium salt, and an electrolyte additive that improves compatibility and performance of the lithium-ion battery with a high voltage cathode. The lithium-ion battery is charged to a voltage in a range of from about 2.0 V (Volts) to about 5.0 V (Volts).

  7. Spontaneous aggregation of lithium ion coordination polymers in fluorinated electrolytes for high-voltage batteries.

    Science.gov (United States)

    Malliakas, Christos D; Leung, Kevin; Pupek, Krzysztof Z; Shkrob, Ilya A; Abraham, Daniel P

    2016-04-28

    Fluorinated carbonates are pursued as liquid electrolyte solvents for high-voltage Li-ion batteries. Here we report aggregation of [Li(+)(FEC)3]n polymer species in fluoroethylene carbonate containing electrolytes and scrutinize the causes for this behavior.

  8. Frequency dependent rectifier memristor bridge used as a programmable synaptic membrane voltage generator

    Directory of Open Access Journals (Sweden)

    Oliver Pabst

    2013-03-01

    Full Text Available Reasoned by its dynamical behavior, the memristor enables a lot of new applications in analog circuit design. Since some realizations have been shown (e.g. 2007 by Hewlett Packard, the development of applications with memristors becomes more and more interesting. Besides applications in neural networks and storage devices, analog memristive circuits also promise further applications. Therefore, this article proposes a frequency dependent rectifier memristor bridge for different purposes, for example, using as a programmable synaptic membrane voltage generator for Spike-Time-Dependent-Plasticity and describes the circuit theory. In this context it is shown that the Picard Iteration is one possibility to analytically solve the system of nonlinear state equations of memristor circuits. An intuitive picture of how a memristor works in a network in general is given as well and in this context some research on the dynamical behavior of a HP memristor should be done. After all it is suggested to use the memristor bridge as a neuron.

  9. Load Concentration Factor Based Analytical Method for Optimal Placement of Multiple Distribution Generators for Loss Minimization and Voltage Profile Improvement

    NARCIS (Netherlands)

    Shahzad, Mohsin; Ahmad, Ishtiaq; Gawlik, Wolfgang; Palensky, P.

    2016-01-01

    This paper presents novel separate methods for finding optimal locations, sizes of multiple distributed generators (DGs) simultaneously and operational power factor in order to minimize power loss and improve the voltage profile in the distribution system. A load concentration factor (LCF) is

  10. AC Voltage Control of DC/DC Converters Based on Modular Multilevel Converters in Multi-Terminal High-Voltage Direct Current Transmission Systems

    Directory of Open Access Journals (Sweden)

    Rui Li

    2016-12-01

    Full Text Available The AC voltage control of a DC/DC converter based on the modular multilevel converter (MMC is considered under normal operation and during a local DC fault. By actively setting the AC voltage according to the two DC voltages of the DC/DC converter, the modulation index can be near unity, and the DC voltage is effectively utilized to output higher AC voltage. This significantly decreases submodule (SM capacitance and conduction losses of the DC/DC converter, yielding reduced capital cost, volume, and higher efficiency. Additionally, the AC voltage is limited in the controllable range of both the MMCs in the DC/DC converter; thus, over-modulation and uncontrolled currents are actively avoided. The AC voltage control of the DC/DC converter during local DC faults, i.e., standby operation, is also proposed, where only the MMC connected on the faulty cable is blocked, while the other MMC remains operational with zero AC voltage output. Thus, the capacitor voltages can be regulated at the rated value and the decrease of the SM capacitor voltages after the blocking of the DC/DC converter is avoided. Moreover, the fault can still be isolated as quickly as the conventional approach, where both MMCs are blocked and the DC/DC converter is not exposed to the risk of overcurrent. The proposed AC voltage control strategy is assessed in a three-terminal high-voltage direct current (HVDC system incorporating a DC/DC converter, and the simulation results confirm its feasibility.

  11. Detailed Behavior Analysis for High Voltage Bidirectional Flyback Converter Driving DEAP Actuator

    DEFF Research Database (Denmark)

    Huang, Lina; Zhang, Zhe; Andersen, Michael A. E.

    2013-01-01

    flyback based converter has been implemented. The parasitic elements have serious influence for the operation of the converter, especially in the high output voltage condition. The detailed behavior analysis has been performed considering the impact of the critical parasitic parameters. The converter has...... been analyzed for both charging and discharging processes in low and high output voltage operating occasions. The experimental waveforms can validate the analysis....

  12. Preparation and characterization of EPDM-silica nano/micro composites for high voltage insulation applications

    OpenAIRE

    Ali Muhammad; Choudhry Muhammad Ahmad

    2015-01-01

    The rising market for substitute materials in high voltage insulation components is stimulated largely by the need to reduce overall costs. In this respect, polymer insulators offer significant advantages over old traditional materials. In the present research, efforts have been made to quantify the effect of silica (having different particle size nano, micro and hybrid) loading on the mechanical and thermal behaviors of Ethylene-Propylene-Diene Monomer (EPDM) based high voltage electrical in...

  13. Static Electricity as Part of Electromagnetic Environment on High-Voltage Electrical Substation

    Directory of Open Access Journals (Sweden)

    M. I. Fursanov

    2012-01-01

    Full Text Available Causes of occurrences electrostatic discharges (ESD on high-voltage electric substation were investigated and dependences values ESD’s on parameters interaction structures, humidity of air were found. Experimental research values ESD’s on high-voltage electric substation and in man-made conditions was fulfilled. Uncertainty measurement’s was taken into consideration by research results analyze. Matching with research of other authors was made. Danger ESD’s for electric devises was established.

  14. A STUDY ON LOSS & COST MINIMIZATION BY USING HIGH VOLTAGE DISTRIBUTION SYSTEM

    OpenAIRE

    P. Hussain Khan*, Ch. Punya Sekhar

    2016-01-01

    This paper presents a converter free system to improve the loss minimization and to reduce the cost of power distribution. The high voltage distribution system is implemented to reduce the loss in the present distribution system. The detailed cost estimation and loss minimization in high voltage distribution system is calculated through simulation results. These performance analysis are presented in this paper.      

  15. High-voltage electroporation of bacteria: genetic transformation of Campylobacter jejuni with plasmid DNA.

    OpenAIRE

    Miller, J F; Dower, W J; Tompkins, L S

    1988-01-01

    Electroporation permits the uptake of DNA by mammalian cells and plant protoplasts because it induces transient permeability of the cell membrane. We investigated the utility of high-voltage electroporation as a method for genetic transformation of intact bacterial cells by using the enteric pathogen Campylobacter jejuni as a model system. This report demonstrates that the application of high-voltage discharges to bacterial cells permits genetic transformation. Our method involves exposure of...

  16. Study of the plasma interference with high voltage electrode array for space power application

    OpenAIRE

    Iwasa, Minoru; Tanaka, Koji; Sasaki, Susumu; Odawara, Osamu; 岩佐 稔; 田中 孝治; 佐々木 進; 小田原 修

    2005-01-01

    We are studying the problems associated with high voltage power systems in space. Especially we are interested in the potential distribution of the solar array that is resistant to the electrical discharge. We have carried out experiments on the interaction between the high voltage solar array and the ambient plasma. In the experiment, an array of electrodes distributed on the insulation panel was used to simulate the inter-connectors of the solar array. An electrode array without the insulat...

  17. Analysis and mitigation of external factors induced failures in high voltage equipment

    OpenAIRE

    AKALP, Onur; Kaya, İbrahim; Efe, Serhat Berat

    2016-01-01

    In this study, insulators and switchyard equipment with porcelain outer surface with the most experienced equipment failures in high voltage power systems have been investigated. The effects of the external environment cause malfunctions in these equipments are determined. Due to the external environment effects failures occurring in equipment were examined. Firstly, high-voltage switchgear equipments which are the subject of study are explained. These include circuit breakers, disconnectors,...

  18. Voltage amplification of thermopower waves via current crowding at high resistances in self-propagating combustion waves

    Science.gov (United States)

    Yeo, Taehan; Hwang, Hayoung; Cho, Yonghwan; Shin, Dongjoon; Choi, Wonjoon

    2015-07-01

    Combustion wave propagation in micro/nanostructured materials generates a chemical-thermal-electrical energy conversion, which enables the creation of an unusual source of electrical energy, called a thermopower wave. In this paper, we report that high electrical resistance regimes would significantly amplify the output voltage of thermopower waves, because the current crowding creates a narrow path for charge carrier transport. We show that the structurally defective regions in the hybrid composites of chemical fuels and carbon nanotube (CNT) arrays determine both the resistance levels of the hybrid composites and the corresponding output voltage of thermopower waves. A sudden acceleration of the crowded charges would be induced by the moving reaction front of the combustion wave when the supplied driving force overcomes the potential barrier to cause charge carrier transport over the defective region. This property is investigated experimentally for the locally manipulated defective areas using diverse methods. In this study, thermopower waves in CNT-based hybrid composites are able to control the peak voltages in the range of 10-1000 mV by manipulating the resistance from 10 Ω to 100 kΩ. This controllable voltage generation from thermopower waves may enable applications using the combustion waves in micro/nanostructured materials and better understanding of the underlying physics.

  19. Optimal reactive power and voltage control in distribution networks with distributed generators by fuzzy adaptive hybrid particle swarm optimisation method

    DEFF Research Database (Denmark)

    Chen, Shuheng; Hu, Weihao; Su, Chi

    2015-01-01

    A new and efficient methodology for optimal reactive power and voltage control of distribution networks with distributed generators based on fuzzy adaptive hybrid PSO (FAHPSO) is proposed. The objective is to minimize comprehensive cost, consisting of power loss and operation cost of transformers...... that the proposed method can search a more promising control schedule of all transformers, all capacitors and all distributed generators with less time consumption, compared with other listed artificial intelligent methods....

  20. A New Approach to High Efficincy in Isolated Boost Converters for High-Power Low-Voltage Fuel Cell Apllications

    DEFF Research Database (Denmark)

    Nymand, Morten; Andersen, Michael A. E.

    2008-01-01

    A new low-leakage-inductance low-resistance design approach to low-voltage high-power isolated boost converters is presented. Very low levels of parasitic circuit inductances are achieved by optimizing transformer design and circuit lay-out. Primary side voltage clamp circuits can be eliminated b...

  1. A research technique for the effect of higher harmonic voltages on the operating parameters of a permanent magnet synchronous generator

    Directory of Open Access Journals (Sweden)

    Hasanova L. H.

    2017-12-01

    Full Text Available Nowadays permanent magnet synchronous machines those frequency-controlled from stator side with frequency inverters made on the basis of power transistors or fully controlled thyristors, are widely used as motors and generators. In future they are also promising a good application in transport, including marine. Modern frequency inverters are equipped with a control system based on sine-shaped pulse width modulation. While shaping the voltage in the output of the inverter, in addition to the fundamental harmonic, higher harmonic components are also included in the voltage shape, which certainly affect the operating parameters of the generator (electromagnetic torque, power, currents. To determine this effect the modeling and investigation technique of higher harmonic voltages in the "electric network – frequency converter – synchronous machine with permanent magnets" system has been developed. The proposed equations of a frequency-controlled permanent magnet synchronous machine allow relatively simply reproduce the harmonic composition of the voltage in the output of a frequency inverter equipped with the control system based on a sinusoidal pulse width modulation. The developed research technique can be used for inverters with any number and composition of voltage harmonic components feeding a stator winding of a permanent magnet synchronous machine. On a particular case, the efficiency of the research technique of the higher harmonics influence on the operating parameters of the generator has been demonstrated. At the same time, the study has been carried out taking into account the shape of the voltage curve feeding the windings of the synchronous machine containing in addition to the fundamental harmonic the 8, 10, 11, 13, 14 and 16-th harmonic components, and the rated active power of the synchronous machine has been equal to 1 500 kW.

  2. Design and Development of Autonomous High Voltage Driving System for DEAP Actuator in Radiator Thermostat

    DEFF Research Database (Denmark)

    Huang, Lina; Zhang, Zhe; Andersen, Michael A. E.

    2014-01-01

    make a high voltage capacitive load driving system to be necessary. The only energy source battery determines it needs to be an autonomous system. The detailed system specifications have been introduced and the corresponding system level design has been proposed. In addition, the detailed design......In radiator thermostat applications, DEAP (Dielectric Electro Active Polymer) actuator tends to be a good candidate to replace the conventional self-actuating or step motor based actuator due to its intrinsic advantages. The capacitive property and high voltage (HV) driving demand of DEAP actuator...... and implementation information has been provided as well, including the power and control stage inside the high voltage converter, the output voltage measurement circuit, the feedback control, etc. Finally, the experimental results have been provided to validate the capability and performance of the driving system....

  3. Design and construction of prototype transversely excited atmospheric (TEA nitrogen laser energized by a high voltage electrical discharge

    Directory of Open Access Journals (Sweden)

    Mukhtar Hussain

    2015-07-01

    Full Text Available The present study reports design and construction, of a prototype of Transversely Excited Atmospheric (TEA nitrogen laser, and a high voltage power supply to excite N2 gas in air, while air is used as an active lasing medium. A Blumlein line discharge circuit is used for operation of this laser. The high voltage is generated by a fly back transformer based power supply varying from 10 kV to 20 kV. The wavelength (337.1 nm of TEA nitrogen laser is measured employing a standard commercial spectrometer and the laser output energy of 300 μJ is measured from the constructed system. Different parameters such as beam profile, laser output spectrum, laser efficiency, and variation of E/P (Electrical field/Pressure value with respect to input voltage and electrodes separations are studied in order to optimize the overall operational efficiency of present nitrogen laser. The analysis of the high voltage prototype appeared in this designed source has also been made and described in this paper.

  4. Self-Healable Electrical Insulation for High Voltage Applications

    Science.gov (United States)

    Williams, Tiffany S.

    2017-01-01

    Polymeric aircraft electrical insulation normally degrades by partial discharge with increasing voltage, which causes excessive localized Joule heating in the material and ultimately leads to dielectric failure of the insulator through thermal breakdown. Developing self-healing insulation could be a viable option to mitigate permanent mechanical degradation, thus increasing the longevity of the insulation. Instead of relying on catalyst and monomer-filled microcapsules to crack, flow, and cure at the damaged sites described in well-published mechanisms, establishment of ionic crosslinks could allow for multiple healing events to occur with the added benefit of achieving full recovery strength under certain thermal environments. This could be possible if the operating temperature of the insulator is the same as or close to the temperature where ionic crosslinks are formed. Surlyn, a commercial material with ionic crosslinks, was investigated as a candidate self-healing insulator based off prior demonstrations of self-healing behavior. Thin films of varying thicknesses were investigated and the effects of thickness on the dielectric strength were evaluated and compared to representative polymer insulators. The effects of thermal conditioning on the recovery strength and healing were observed as a function of time following dielectric breakdown. Moisture absorption was also studied to determine if moisture absorption rates in Surlyn were lower than that of common polyimides.

  5. Modulation of High-Voltage Activated Ca2+ Channels by Membrane Phosphatidylinositol 4,5-Bisphosphate

    Science.gov (United States)

    Suh, Byung-Chang; Leal, Karina; Hille, Bertil

    2010-01-01

    SUMMARY Modulation of voltage-gated Ca2+ channels controls activities of excitable cells. We show that high-voltage activated Ca2+ channels are regulated by membrane phosphatidylinositol 4,5-bisphosphate (PIP2) with different sensitivities. Plasma membrane PIP2 depletion by rapamycin-induced translocation of an inositol lipid 5-phosphatase or by a voltage-sensitive 5-phosphatase (VSP) suppresses CaV1.2 and CaV1.3 channel currents by ~35%, and CaV2.1 and CaV2.2 currents by 29 and 55%, respectively. Other CaV channels are less sensitive. Inhibition is not relieved by strong depolarizing prepulses. It changes the voltage dependence of channel gating little. Recovery of currents from inhibition needs intracellular hydrolysable ATP, presumably for PIP2 resynthesis. When PIP2 is increased by overexpressing PIP 5-kinase, activation and inactivation of CaV2.2 current slow and voltage-dependent gating shifts to slightly higher voltages. Thus, endogenous membrane PIP2 supports high-voltage activated L-, N-, and P/Q- type Ca2+ channels, and stimuli that activate phospholipase C deplete PIP2 and reduce those Ca2+ channel currents. PMID:20670831

  6. Voltage magnitude and margin controller for remote industrial microgrid with high wind penetration

    DEFF Research Database (Denmark)

    Cai, Yu; Lin, Jin; Song, Yonghua

    2013-01-01

    It is well known that the remote industrial microgrid is located at the periphery of the grid, which is weakly connected to the main grid. In order to enhance the voltage stability and ensure a good power quality for industries, a voltage magnitude and margin controller based on wind turbines...... is proposed in this paper. This controller includes two parts to improve voltage stability in different time scales by using local measurements. Case studies conducted for a remote microgrid with high wind penetration have proved the effectiveness of the proposed control scheme....

  7. A Novel Quasi-SEPIC High-Voltage Boost DC-DC Converter

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; N. Soltani, Mohsen; Blaabjerg, Frede

    2017-01-01

    This paper proposes a modified coupled-inductor SEPIC dc-dc converter for low power and high voltage gain applications such as for piezoelectric drive systems. The converter uses the same components as of SEPIC converter with an additional diode. Compared to conventional topologies with similar...... voltage gain expression, the proposed topology uses less components to achieve same or even higher voltage gain. This helps to design a very compact and light weight converter with higher power density at lower cost. Due to brevity, the principle of operation, theoretical analysis and comparison supported...

  8. Behavior of AC High Voltage Polyamide Insulators: Evolution of Leakage Current in Different Surface Conditions

    OpenAIRE

    Mohammed El Amine Slama; Abderrahmane Beroual

    2015-01-01

    This paper is aimed at a systematic study of the leakage current of high voltage polyamide insulator string under different conditions of pollution for possible application in the electric locomotive systems. It is shown that in the case of clean/dry and clean/wetted insulators, the leakage current and applied voltage are linear. While in the case of pollution with saline spray, the leakage current and the applied voltage are not linear; the leakage current changes from a linear regime to a n...

  9. Behavior of AC High Voltage Polyamide Insulators: Evolution of Leakage Current in Different Surface Conditions

    Directory of Open Access Journals (Sweden)

    Mohammed El Amine Slama

    2015-01-01

    Full Text Available This paper is aimed at a systematic study of the leakage current of high voltage polyamide insulator string under different conditions of pollution for possible application in the electric locomotive systems. It is shown that in the case of clean/dry and clean/wetted insulators, the leakage current and applied voltage are linear. While in the case of pollution with saline spray, the leakage current and the applied voltage are not linear; the leakage current changes from a linear regime to a nonlinear regime up to total flashover of the insulators sting. Traces of erosion and tracking of insulators resulting of partial discharges are observed.

  10. An AT89C52 Microcontroller Based High Resolution PWM Controller for 3-Phase Voltage Source Inverters

    Directory of Open Access Journals (Sweden)

    K. M. Rahman and S. J. M. Idrus

    2012-10-01

    Full Text Available A novel technique for generating real time high resolution pulse width modulated patterns for a three phase voltage source inverter is presented in this paper. An AT89C52 microcontroller computes the PWM pulse widths on carrier cycle basis based on the input frequency.  The microcontroller send the pulse width information for the three phases to a memory minimized ROM lookup table, which is scanned by a binary counter to generate the real time PWM patterns. The on board timer of AT89C52 is utilized to generate programmed clock for the scanning binary counter. The overall design is hardware minimized and compact that makes it feasible for low cost high performance ac drive applications.  The proposed PWM controller supports variable frequency variable voltage operation for wide range and hence is ideally suited for industrial drives requiring wide speed variations.  Keywords: Pulse width modulation, Microcontroller application, Voltage source inverter, variable speed ac drives.

  11. High voltage pulses for high impedance loads using explosive formed fuses

    Energy Technology Data Exchange (ETDEWEB)

    Degnan, J.H.; Kiuttu, G.F.; Turchi, P.J. [Air Force Research Labs., Kirtland AFB, NM (United States). Phillips Research Site; Goforth, J.H.; Lopez, E.A.; Oona, H.; Tasker, D.G. [Los Alamos National Lab., NM (United States); Graham, J.D.

    1998-10-01

    Explosive formed fuses (EFF`s) use conducting elements that are deformed by explosive pressure (typically, against dielectric dies). This causes the fuse geometry to change, so that the conducting element cross section decreases. This enables a higher ratio of current conduction to current interrupt time than for normal fuses, and it enables more control of when current interruption occurs. In combination with a suitable output closing switch, EFF`s can be used to obtain several hundred kilovolt voltage pulses from inductive stores to drive several ohm loads. With proper choices of inductive store, EFF geometry and material, and output closing switch features, such a voltage pulse can be approximately flat topped for microsecond duration and have a small fraction of microsecond risetime. The authors present theoretical analysis and circuit simulations which illustrate this, using scaled empirical EFF parameters for inductive stores in the 1 weber flux, several hundred nanohenry range. The circuit simulations were done using MicroCap-IV, with user defined elements. These simulations were done with static inductive stores and with explosive magnetic flux compression generators driving inductive stores.

  12. Electric Field Simulations and Analysis for High Voltage High Power Medium Frequency Transformer

    Directory of Open Access Journals (Sweden)

    Pei Huang

    2017-03-01

    Full Text Available The electronic power transformer (EPT raises concerns for its notable size and volume reduction compared with traditional line frequency transformers. Medium frequency transformers (MFTs are important components in high voltage and high power energy conversion systems such as EPTs. High voltage and high power make the reliable insulation design of MFT more difficult. In this paper, the influence of wire type and interleaved winding structure on the electric field distribution of MFT is discussed in detail. The electric field distributions for six kinds of typical non-interleaved windings with different wire types are researched using a 2-D finite element method (FEM. The electric field distributions for one non-interleaved winding and two interleaved windings are also studied using 2-D FEM. Furthermore, the maximum electric field intensities are obtained and compared. The results show that, in this case study, compared with foil conductor, smaller maximum electric field intensity can be achieved using litz wire in secondary winding. Besides, interleaving can increase the maximum electric field intensity when insulation distance is constant. The proposed method of studying the electric field distribution and analysis results are expected to make a contribution to the improvement of electric field distribution in transformers.

  13. High-Voltage, High-Power Gaseous Electronics Switch For Electric Grid Power Conversion

    Science.gov (United States)

    Sommerer, Timothy J.

    2014-05-01

    We are developing a high-voltage, high-power gas switch for use in low-cost power conversion terminals on the electric power grid. Direct-current (dc) power transmission has many advantages over alternating current (ac) transmission, but at present the high cost of ac-dc power interconversion limits the use of dc. The gas switch we are developing conducts current through a magnetized cold cathode plasma in hydrogen or helium to reach practical current densities > 1 A/cm2. Thermal and sputter damage of the cathode by the incident ion flux is a major technical risk, and is being addressed through use of a ``self-healing'' liquid metal cathode (eg, gallium). Plasma conditions and cathode sputtering loss are estimated by analyzing plasma spectral emission. A particle-in-cell plasma model is used to understand various aspects of switch operation, including the conduction phase (where plasma densities can exceed 1013 cm-3), the switch-open phase (where the high-voltage must be held against gas breakdown on the left side of Paschen's curve), and the switching transitions (especially the opening process, which is initiated by forming an ion-matrix sheath adjacent to a control grid). The information, data, or work presented herein was funded in part by the Advanced Research Projects Agency-Energy (ARPA-E), U.S. Department of Energy, under Award Number DE-AR0000298.

  14. Design of load-to-failure tests of high-voltage insulation breaks for ITER's cryogenic network

    CERN Document Server

    Langeslag, S A E; Aviles Santillana, I; Sgobba, S; Foussat, A

    2015-01-01

    The development of new generation superconducting magnets for fusion research, such as the ITER experiment, is largely based on coils wound with so-called cable-in-conduit conductors. The concept of the cable-in-conduit conductor is based on a direct cooling principle, by supercritical helium, flowing through the central region of the conductor, in close contact with the superconducting strands. Consequently, a direct connection exists between the electrically grounded helium coolant supply line and the highly energised magnet windings. Various insulated regions, constructed out of high-voltage insulation breaks, are put in place to isolate sectors with different electrical potential. In addition to high voltages and significant internal helium pressure, the insulation breaks will experience various mechanical forces resulting from differential thermal contraction phenomena and electro-magnetic loads. Special test equipment was designed, prepared and employed to assess the mechanical reliability of the insul...

  15. The design and development of low- and high-voltage ASICs for space-borne CCD cameras

    Science.gov (United States)

    Waltham, N.; Morrissey, Q.; Clapp, M.; Bell, S.; Jones, L.; Torbet, M.

    2017-11-01

    The CCD remains the pre-eminent visible and UV wavelength image sensor in space science, Earth and planetary remote sensing. However, the design of space-qualified CCD readout electronics is a significant challenge with requirements for low-volume, low-mass, low-power, high-reliability and tolerance to space radiation. Space-qualified components are frequently unavailable and up-screened commercial components seldom meet project or international space agency requirements. In this paper, we describe an alternative approach of designing and space-qualifying a series of low- and high-voltage mixed-signal application-specific integrated circuits (ASICs), the ongoing development of two low-voltage ASICs with successful flight heritage, and two new high-voltage designs. A challenging sub-system of any CCD camera is the video processing and digitisation electronics. We describe recent developments to improve performance and tolerance to radiation-induced single event latchup of a CCD video processing ASIC originally developed for NASA's Solar Terrestrial Relations Observatory and Solar Dynamics Observatory. We also describe a programme to develop two high-voltage ASICs to address the challenges presented with generating a CCD's bias voltages and drive clocks. A 0.35 μm, 50 V tolerant, CMOS process has been used to combine standard low-voltage 3.3 V transistors with high-voltage 50 V diffused MOSFET transistors that enable output buffers to drive CCD bias drains, gates and clock electrodes directly. We describe a CCD bias voltage generator ASIC that provides 24 independent and programmable 0-32 V outputs. Each channel incorporates a 10-bit digital-to-analogue converter, provides current drive of up to 20 mA into loads of 10 μF, and includes current-limiting and short-circuit protection. An on-chip telemetry system with a 12-bit analogue-to-digital converter enables the outputs and multiple off-chip camera voltages to be monitored. The ASIC can drive one or more CCDs and

  16. The design and development of low- and high-voltage ASICs for space-borne CCD cameras

    Science.gov (United States)

    Waltham, N.; Morrissey, Q.; Clapp, M.; Bell, S.; Jones, L.; Torbet, M.

    2017-12-01

    The CCD remains the pre-eminent visible and UV wavelength image sensor in space science, Earth and planetary remote sensing. However, the design of space-qualified CCD readout electronics is a significant challenge with requirements for low-volume, low-mass, low-power, high-reliability and tolerance to space radiation. Space-qualified components are frequently unavailable and up-screened commercial components seldom meet project or international space agency requirements. In this paper, we describe an alternative approach of designing and space-qualifying a series of low- and high-voltage mixed-signal application-specific integrated circuits (ASICs), the ongoing development of two low-voltage ASICs with successful flight heritage, and two new high-voltage designs. A challenging sub-system of any CCD camera is the video processing and digitisation electronics. We describe recent developments to improve performance and tolerance to radiation-induced single event latchup of a CCD video processing ASIC originally developed for NASA's Solar Terrestrial Relations Observatory and Solar Dynamics Observatory. We also describe a programme to develop two high-voltage ASICs to address the challenges presented with generating a CCD's bias voltages and drive clocks. A 0.35 μm, 50 V tolerant, CMOS process has been used to combine standard low-voltage 3.3 V transistors with high-voltage 50 V diffused MOSFET transistors that enable output buffers to drive CCD bias drains, gates and clock electrodes directly. We describe a CCD bias voltage generator ASIC that provides 24 independent and programmable 0-32 V outputs. Each channel incorporates a 10-bit digital-to-analogue converter, provides current drive of up to 20 mA into loads of 10 μF, and includes current-limiting and short-circuit protection. An on-chip telemetry system with a 12-bit analogue-to-digital converter enables the outputs and multiple off-chip camera voltages to be monitored. The ASIC can drive one or more CCDs and

  17. A Novel Transformerless DC–DC Converters With High Step-Up Voltage Gain And Low Voltage Stress On The Switch

    Directory of Open Access Journals (Sweden)

    hossein ajdarfaeghi

    2016-10-01

    Full Text Available In this paper, a single switch transformerless high step up dc-dc converter with low voltage stress on the switch is proposed. In the proposed converter only one switch is used which makes the control scheme simple as well as reducing the switching power loss. The voltage gain of the proposed converter is higher than the conventional boost converter and buck boost converter and Proposed converter works in wide rang than conventional converters. The proposed converter has low voltage stress on the switch which makes reducing the switching power loss. The proposed converter can be operated in the continuous conduction mode (CCM and the discontinuous conduction mode (DCM. In this paper, different operation modes of the proposed converter, calculation of the voltage gain, the currents that flow through the components, efficiency and capacitors voltage ripple are presented. To verify the operation of the proposed converter, simulation results via PSCAD software and experimental results are provided.

  18. Derivation of Parabolic Current Control with High Precision, Fast Convergence and Extended Voltage Control Application

    OpenAIRE

    Zhang, Lanhua

    2016-01-01

    Current control is an important topic in modern power electronics system. For voltage source inverters, current control loop ensures the waveform quality at steady state and the fast response at transient state. To improve the current control performance, quite a few nonlinear control strategies have been presented and one well-known strategy is the hysteresis current control. It achieves fast response without stability issue and it has high control precision. However, for voltage source inve...

  19. Effect of Doubly Fed Induction GeneratorTidal Current Turbines on Stability of a Distribution Grid under Unbalanced Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Dahai Zhang

    2017-02-01

    Full Text Available This paper analyses the effects of doubly fed induction generator (DFIG tidal current turbines on a distribution grid under unbalanced voltage conditions of the grid. A dynamic model of an electrical power system under the unbalanced network is described in the paper, aiming to compare the system performance when connected with and without DFIG at the same location in a distribution grid. Extensive simulations of investigating the effect of DFIG tidal current turbine on stability of the distribution grid are performed, taking into account factors such as the power rating, the connection distance of the turbine and the grid voltage dip. The dynamic responses of the distribution system are examined, especially its ability to ride through fault events under unbalanced grid voltage conditions. The research has shown that DFIG tidal current turbines can provide a good damping performance and that modern DFIG tidal current power plants, equipped with power electronics and low-voltage ride-through capability, can stay connected to weak electrical grids even under the unbalanced voltage conditions, whilst not reducing system stability.

  20. Atmospheric pressure plasma jet with high-voltage power supply based on piezoelectric transformer.

    Science.gov (United States)

    Babij, Michał; Kowalski, Zbigniew W; Nitsch, Karol; Silberring, Jerzy; Gotszalk, Teodor

    2014-05-01

    The dielectric barrier discharge plasma jet, an example of the nonthermal atmospheric pressure plasma jet (APPJ), generates low-temperature plasmas that are suitable for the atomization of volatile species and can also be served as an ionization source for ambient mass and ion mobility spectrometry. A new design of APPJ for mass spectrometry has been built in our group. In these plasma sources magnetic transformers (MTs) and inductors are typically used in power supplies but they present several drawbacks that are even more evident when dealing with high-voltage normally used in APPJs. To overcome these disadvantages, high frequency generators with the absence of MT are proposed in the literature. However, in the case of miniaturized APPJs these conventional power converters, built of ferromagnetic cores and inductors or by means of LC resonant tank circuits, are not so useful as piezoelectric transformer (PT) based power converters due to bulky components and small efficiency. We made and examined a novel atmospheric pressure plasma jet with PT supplier served as ionization source for ambient mass spectrometry, and especially mobile spectrometry where miniaturization, integration of components, and clean plasma are required. The objective of this paper is to describe the concept, design, and implementation of this miniaturized piezoelectric transformer-based atmospheric pressure plasma jet.