WorldWideScience

Sample records for high specific-activity gamma-emitting

  1. Metrological aspects of radiochemical methods for determining activity of gamma-emitting nuclides

    International Nuclear Information System (INIS)

    Shcherbakov, B.Y.

    1986-01-01

    The author considers the problem of metrological compatibility of the two stages in the radiochemical method of determining the activity of a gamma-emitting nuclide: chemical isolation of the nuclide and radiometric measurement of its activity. The authors show that preparation of the specimen in liquid form provides for important advantages compared with the traditional application of the solid residue onto a flat substate. The work here is of interest for analytical chemists who are involved with determination of the activity of gamma emitting nuclides such as Ru 103, Rh 106, Sn 113, Cs 134, Cs 137, La 140, Ce 141, Ce 144, Hg 203, Na 24, Mn 54, Fe 59, Co 60, Zn 65, Zr 95, and Nb 95, for example, in waste water or in emissions to the atmosphere, with the goal of protecting the environment

  2. ORNL shielded facilities capable of remote handling of highly radioactive beta--gamma emitting materials

    International Nuclear Information System (INIS)

    Whitson, W.R.

    1977-09-01

    A survey of ORNL facilities having adequate shielding and containment for the remote handling of experimental quantities of highly radioactive beta-gamma emitting materials is summarized. Portions of the detailed descriptions of these facilities previously published in ORNL/TM-1268 are still valid and are repeated

  3. Mixed gamma emitting gas standard and method

    International Nuclear Information System (INIS)

    McFarland, R.C.; McFarland, P.A.

    1986-01-01

    The invention in one aspect pertains to a method of calibrating gamma spectroscopy systems for gas counting in a variety of counting containers comprising withdrawing a precision volume of a mixed gamma-emitting gas standard from a precision volume vial and delivering the withdrawn precision volume of the gas standard to the interior of a gas counting container. Another aspect of the invention pertains to a mixed gamma-emitting gas standard, comprising a precision spherical vial of predetermined volume, multiple mixed emitting gas components enclosed within the vial, and means for withdrawing from the vial a predetermined amount of the components wherein the gas standard is used to calibrate a gamma spectrometer system for gas counting over a wide energy range without the use of additional standards. A third aspect comprehends a gamma spectrometer calibration system for gas counting, comprising a precision volume spherical glass vial for receiving mixed multiisotope gas components, and two tubular arms extending from the vial. A ground glass stopcock is positioned on each arm, and the outer end of one arm is provided with a rubber septum port

  4. Activity concentrations and mean annual effective dose from gamma-emitting radionuclides in the Lebanese diet

    International Nuclear Information System (INIS)

    Nasreddine, L.; Hwalla, N.; El Samad, O.; Baydoun, R.; Hamze, M.; Parent-Massin, D.

    2008-01-01

    Since the primary factor contributing to the internal effective dose in the human organism is contaminated food, the control of radionuclides in food represents the most important means of protection. This study was conducted to determine the levels of the dietary exposure of the Lebanese population to gamma-emitting radioisotopes. The activity concentrations of gamma-emitting radioisotopes have been measured in food samples that represent the market basket of an adult urban population in Lebanon. The artificial radionuclide 137 Cs was measured above detection limits in only fish, meat and milk-based deserts. The most abundant natural radionuclide was 40 K (31-121 Bq kg -1 ), with the highest content in fish and meat samples. The annual mean effective dose contributed by 40 K in the reference typical diet was estimated equal to 186 μSv y -1 , a value reasonably consistent with findings reported by several other countries. (authors)

  5. Multiplicity and correlated energy of gamma rays emitted in the spontaneous fission of Californium-252

    International Nuclear Information System (INIS)

    Brunson, G.S. Jr.

    1982-06-01

    An array of eight high-speed plastic scintillation detectors has been used to infer a mathematical model for the emission multipliciy of prompt gammas in the spontaneous fission of 252 Cf. Exceptional time resolution and coincidence capability permitted the separation of gammas from fast neutrons over a flight path of approximately 10 cm. About 20 different distribution models were tested. The average energy of the prompt gammas is inversely related to the number emitted; however, this inverse relationship is not strong and the total gamma energy does increase with increasing gamma number. An extension of the experiment incorporated a lithium-drifted germanium gamma spectrometer that resolved nearly 100 discrete gammas associated with fission. Of these gammas, some were preferentially associated with fission in which few gammas were emitted. Certain others were more frequent when many gammas were emitted. Results are presented

  6. Bioaccumulation of gamma emitting radionuclides in Polysiphonia fucoides

    International Nuclear Information System (INIS)

    Tamara Zalewska

    2014-01-01

    The article presents the results of a study on the bioaccumulation abilities of Polysiphonia fucoides, a red algae specific to the southern Baltic Sea, towards (of) gamma emitting isotopes. A laboratory experiment was carried out to determine changes in the activities of some isotopes - 54 Mn, 57 Co, 65 Zn, 110m Ag, 113 Sn, 134 Cs, 137 Cs and 241 Am - occurring in P. fucoides exposed to a seawater medium containing these isotopes over the course of 1 month. All analyzed isotopes showed the greatest increase of radioactive activity in plant tissue in the first 24 h of exposure. The temporary concentration factors of cesium isotopes were increasing linearly during the experiment from 114 to 274 in the case of 137 Cs, and from 144 to 351 in the case of 134 Cs. The level of the initial concentration factor of cesium isotopes in the plant proved to be independent of the initial concentration of the isotope in seawater and it took the lowest (125 dm 3 kg -1 ) level among the studied isotopes. In the case of a mixture of gamma emitting isotopes, a linear relation between the individual isotope activity in P. fucoides and its initial concentration in seawater was established after the first day of exposure; the isotopes initial concentration factors ranged from 767 to 874 dm 3 kg -1 . Having reached the maximal concentration level, a statistically significant decline in radioactivity concentrations of the five isotopes in the plant tissue was observed. A half-life of biological removal of the isotopes from the plant tissue was established at: 3.8 days in the case of 54 Mn, 4 days- 57 Co, 4 days- 60 Co, 4.2 days- 137 Cs and 241 Am-3.5 days. (author)

  7. Procedure for the elaboration of extended sources beta and/or gamma emitting

    International Nuclear Information System (INIS)

    Tejera R, A.; Cortes P, A.; Becerril V, A.

    1991-12-01

    In the laboratory of radioactive standards they have been come manufacturing punctual sources gauged gamma emitting during several years. Before the demand of extended radioactive homogeneous sources of beta particles emitting, in particular with nuclides that are simultaneously gamma and beta emitting, it was designed a procedure for it elaboration based on the one that we use at the moment for the elaboration of the punctual gamma sources. This procedure consists on the integration of a compact group of this type of sources on a single extended support, sealed one of its faces with a film of transparent material in satisfactory grade to the beta particles. In this work this procedure is described and it is applied in the elaboration of two sources that its were requested by the Laguna Verde Central (CFE), one with area of 20 cm 2 and the other one of 100 cm 2 . The homogeneity, measure as the dispersion of the activities of the aliquot ones distributed in the active surfaces was inside 2%. The percentage of attenuation of the beta particles was also measured by the film (window) with the one that the sources were sealed. (Author)

  8. The distribution and abundance of gamma emitting radionuclides in Lake Ontario sediments

    International Nuclear Information System (INIS)

    McKinley, R.S.

    1985-03-01

    The distribution of gamma emitting radionuclides in Lake Ontario sediments was investigated. Samples were collected using a systematic design in the vicinity of Pickering and Darlington, and supplemented by lakewide offshore samples. Naturally occurring 40 K was the predominant source of gamma activity. 60 Co was the only potentially CANDU released radionuclide which showed a distributional association with the Pickering 'A' NGS discharge

  9. Calibration of gamma cameras for the evaluation of accidental intakes of high-energy photon emitting radionuclides by humans based on urine samples

    Energy Technology Data Exchange (ETDEWEB)

    Degenhardt, A.L.; Lucena, E.A.; Reis, A.A. dos; Souza, W.O.; Dantas, A.L.A.; Dantas, B.M., E-mail: bmdantas@ird.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Dosimetria

    2017-07-01

    The prompt response to emergency situations involving suspicion of intakes of radionuclides requires the use of simple and rapid methods of internal monitoring of the exposed individuals. The use of gamma cameras to estimate intakes and committed doses was investigated by the Centers for Disease Control and Preventions (CDC) of the USA in 2010.The present study aims to develop a calibration protocol for gamma cameras to be applied on internal monitoring based on urine samples to evaluate the incorporation of high-energy photon emitting radionuclides in emergency situations. A gamma camera available in a public hospital located in the city of Rio de Janeiro was calibrated using a standard liquid source of {sup 152}Eu supplied by the LNMRI of the IRD.'Efficiency vs Energy' curves at 10 and 30 cm were obtained. Calibration factors, Minimum Detectable Activities and Minimum Detectable Effective Doses of the gamma camera were calculated for {sup 137}Cs and {sup 60}Co. The gamma camera evaluated in this work presents enough sensitivity to detect activities of such radionuclides at dose levels suitable to assess suspected accidental intakes. (author)

  10. Measurement and calculation of characteristic prompt gamma ray spectra emitted during proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Polf, J C; Peterson, S; Beddar, S [M D Anderson Cancer Center, Univeristy of Texas, Houston, TX 77030 (United States); McCleskey, M; Roeder, B T; Spiridon, A; Trache, L [Cyclotron Institute, Texas A and M University, College Station, TX 77843 (United States)], E-mail: jcpolf@mdanderson.org

    2009-11-21

    In this paper, we present results of initial measurements and calculations of prompt gamma ray spectra (produced by proton-nucleus interactions) emitted from tissue equivalent phantoms during irradiations with proton beams. Measurements of prompt gamma ray spectra were made using a high-purity germanium detector shielded either with lead (passive shielding), or a Compton suppression system (active shielding). Calculations of the spectra were performed using a model of both the passive and active shielding experimental setups developed using the Geant4 Monte Carlo toolkit. From the measured spectra it was shown that it is possible to distinguish the characteristic emission lines from the major elemental constituent atoms (C, O, Ca) in the irradiated phantoms during delivery of proton doses similar to those delivered during patient treatment. Also, the Monte Carlo spectra were found to be in very good agreement with the measured spectra providing an initial validation of our model for use in further studies of prompt gamma ray emission during proton therapy. (note)

  11. Calculation of the gamma-dose rate from a continuously emitted plume

    International Nuclear Information System (INIS)

    Huebschmann, W.; Papadopoulos, D.

    1975-06-01

    A computer model is presented which calculates the long term gamma dose rate caused by the radioactive off-gas continuously emitted from a stack. The statistical distribution of the wind direction and velocity and of the stability categories is taken into account. The emitted activity, distributed in the atmosphere according to this statistics, is assumed to be concentrated at the mesh points of a three-dimensional grid. The grid spacing and the integration limits determine the accuracy as well as the computer time needed. When calculating the dose rate in a given wind direction, the contribution of the activity emitted into the neighbouring sectors is evaluated. This influence is demonstrated in the results, which are calculated with a error below 3% and compared to the dose rate distribution curves of the submersion model and the model developed by K.J. Vogt. (orig.) [de

  12. ZZ TPASGAM-85, Gamma Spectra Data Library for Activation Analysis

    International Nuclear Information System (INIS)

    1995-01-01

    Description of program or function: Format: for use with RSIC code package PSR-164/TPASS. Nuclides: 1438 radionuclides; Origin: Recently-published results and also from Nuclear Data Sheets and Atomic Data and Nuclear Data Tables. The TPASGAM data library contains gamma-ray decay information for 1438 radionuclides. The data consist of gamma-ray energies and intensities as well as cross section information useful in activation analysis. This compilation of radionuclide decay data contains, for those radionuclides tabulated, all necessary data for qualitatively and quantitatively measuring the concentration of photon emitting radionuclides as well as conducting activation analyses using gamma-ray spectrometry. It was developed specifically for use with RSIC code package PSR-164/TPASS

  13. High activity gamma irradiators developed in Hungary

    International Nuclear Information System (INIS)

    Stenger, V.

    1997-01-01

    The development of high activity Gamma irradiators began in Hungary already in the early years of 60s. The very first designs were serving research in irradiation chemistry, radiation physics, food and agricultural research, radiation sterilization, plastic radiation chemistry, radiobiology, cancer therapy, personal and high dose dosimetry, following the international trends. Domestic and new international demands forced us to design and construct High Activity Gamma Irradiators: Multipurpose Pilot, Portable and Large scale bulk, Multipurpose Industrial scale types

  14. Benign prostatic hypertrophy with high levels of gamma-seminoprotein (gamma-Sm), prostate specific antigen: report of two cases

    OpenAIRE

    浅川, 正純; 安本, 亮二; 上水流, 雅人; 前川, 正信

    1988-01-01

    gamma-Seminoprotein (gamma-Sm) is recently being noted as a tumor marker of prostatic cancer. However, since gamma-Sm is a specific antigen against the prostatic tissue, high levels are also observed in patients with benign prostatic hypertrophy (BPH). In this report, two patients with BPH who had high levels of gamma-Sm were studied.

  15. Standard guide for high-resolution gamma-ray spectrometry of soil samples

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This guide covers the identification and quantitative determination of gamma-ray emitting radionuclides in soil samples by means of gamma-ray spectrometry. It is applicable to nuclides emitting gamma rays with an approximate energy range of 20 to 2000 keV. For typical gamma-ray spectrometry systems and sample types, activity levels of about 5 Bq (135 pCi) are measured easily for most nuclides, and activity levels as low as 0.1 Bq (2.7 pCi) can be measured for many nuclides. It is not applicable to radionuclides that emit no gamma rays such as the pure beta-emitting radionuclides hydrogen-3, carbon-14, strontium-90, and becquerel quantities of most transuranics. This guide does not address the in situ measurement techniques, where soil is analyzed in place without sampling. Guidance for in situ techniques can be found in Ref (1) and (2). This guide also does not discuss methods for determining lower limits of detection. Such discussions can be found in Refs (3), (4), (5), and (6). 1.2 This guide can be us...

  16. Tables of nuclear constants for gamma activation analysis

    International Nuclear Information System (INIS)

    Randa, Z.; Kreisinger, F.

    1983-01-01

    Tables of nuclear data were compiled for the purpose of routine gamma (photon) activation analysis. The tables are arranged in two parts. The first one lists the radionuclides in the order of their atomic number. In the second one, the emitted gamma-ray photons are tabulated in the order of increasing energy. Tables contain the gamma emitters produced by the following photonuclear reactions: (#betta#,#betta#), (#betta#,n), (#betta#,p), (#betta#,p+n), (#betta#,2n), (#betta#,3n), (#betta#,4n), (#betta#,2p), (#betta#,α), (#betta#,α+n), (#betta#,α+p). This set corresponds to the maximum energy of the bremsstrahlung of roughly 45 MeV. The program for the output of the tabulated data allows the data as required for specific irradiation and measuring reduction of conditions (reaction thresholds, energy and intensity of gamma-rays, half-lives and target elements). (author)

  17. Specific activities and the relevant gamma ray dose rates at 1 meter from radioisotopes and isomers following thermal neutron capture reaction

    International Nuclear Information System (INIS)

    Eissa, E.A.; Aly, R.A.; Gomaa, M.A.; Hassan, A.M.

    1995-01-01

    Calculations were performed for the specific activity of 245 gamma-ray emitting radioisotopes and isomers produced in 48, 72 and 96 hour irradiation periods of the natural isotopic mixture of their 77 elements with thermal neutron flux 1.0 E + 13 n/cm 2 .5, at the core of the (ET-R R-1) reactor. The relevant gamma-ray dose rate at a point 1 meter apart from each radioisotope or isomer was evaluated whenever the specific gamma-ray dose rate constant is available. The irradiation time factor (ITF) for the irradiation periods 24, 48, 72 and 96 hours are reported for each of the 248 gamma-ray emitters. The average of (ITF) over these 248 radionuclides for each irradiation period is taken as a measure of the feasibility of the irradiation time. The results favour the increase of the irradiation period from the conventional 48 to 72 hours but not to 96 hours. A programme was established in the VAX computer to carry out the above mentioned calculations. Tables of the present work are very useful for isotope production and reactor safety. 1 fig., 2 tabs

  18. A sensitive and quantitative biosensing method for the determination of {gamma}-ray emitting radionuclides in surface water

    Energy Technology Data Exchange (ETDEWEB)

    Wolterbeek, H.Th.; Meer, A.J.G.M. van der [Technische Univ. Delft (Netherlands). Interfacultair Reactor Inst.

    1996-11-01

    A quantitative and sensitive biosensing method has been developed for the determination of {gamma}-ray emitting radionuclides in surface water. The method is based on the concept that at equilibrium the specific radioactivity in the biosensor is equal to the specific radioactivity in water. The method consists of the measurement of both the radionuclide and the element in the biosensor and the determination of the element level in water. This three-way analysis eliminates problems such as unpredictable biosensor behaviour, effects of water elemental composition or further abiotic parameters: what remains is the generally high enrichment (bioaccumulation factor BCF) of elements and radionuclides in the biosensor material. Measurements were performed with floating water plants (Azolla filiculoides Lamk., Spirodela polyrhiza/Lemna sp.) and the fully submerged water plant Ceratophyllum demersum L., which were sampled from ditch water. Concentrations of elements and radionuclides were determined in both water and biosensor plants, using Neutron Activation Analysis (NAA), ICP-MS, and {gamma}-ray spectrometry, respectively. For the latter, both 1 litre samples (Marinelli-geometry) and 1 cm{sup 3} samples (well-type detectors) were applied in measurements. (author).

  19. Radiography apparatus using gamma rays emitted by water activated by fusion neutrons

    Science.gov (United States)

    Smith, Donald L.; Ikeda, Yujiro; Uno, Yoshitomo

    1996-01-01

    Radiography apparatus includes an arrangement for circulating pure water continuously between a location adjacent a source of energetic neutrons, such as a tritium target irradiated by a deuteron beam, and a remote location where radiographic analysis is conducted. Oxygen in the pure water is activated via the .sup.16 O(n,p).sup.16 N reaction using .sup.14 -MeV neutrons produced at the neutron source via the .sup.3 H(d,n).sup.4 He reaction. Essentially monoenergetic gamma rays at 6.129 (predominantly) and 7.115 MeV are produced by the 7.13-second .sup.16 N decay for use in radiographic analysis. The gamma rays have substantial penetrating power and are useful in determining the thickness of materials and elemental compositions, particularly for metals and high-atomic number materials. The characteristic decay half life of 7.13 seconds of the activated oxygen is sufficient to permit gamma ray generation at a remote location where the activated water is transported, while not presenting a chemical or radioactivity hazard because the radioactivity falls to negligible levels after 1-2 minutes.

  20. Utilization of freshly induced high-energy gamma-ray activity as a measure of fission rates in re-irradiated burnt UO{sub 2} fuel

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, M. F.; Perret, G. [Paul Scherrer Institut (PSI), CH-5232 Villigen (Switzerland); Krohnert, H.; Chawla, R. [Paul Scherrer Institut (PSI), CH-5232 Villigen (Switzerland); Ecole Polytechnique Federale de Lausanne (EPFL), CH-1015 Lausanne (Switzerland)

    2009-07-01

    In the frame of the LIFE-PROTEUS (Large-scale Irradiation Fuel Experiments at PROTEUS) program, a measurement technique is being developed to measure fission rates in burnt fuel, following re-irradiation in a zero-power research reactor. In the presented approach, the fission rates are estimated by measuring high energy gamma-rays (above 2000 keV) emitted by short-lived fission products freshly produced in the fuel. Due to their high energies, these gamma-rays can be discriminated against the high intrinsic gamma-ray activity of the burnt fuel, which reaches energies up to 2000 keV. To demonstrate the feasibility of this approach, fresh and burnt fuel samples (with burn-ups varying from 36 to 64 MWd/kg) were irradiated in the PROTEUS reactor at the Paul Scherrer Institut, and their emitted gamma-ray spectra were recorded shortly after irradiation. It was possible, for the first time, to detect the short-lived gamma-ray activity in the high-energy region, even in the presence of the intrinsic gamma-ray background of the burnt fuel samples. Using the short-lived gamma-ray lines {sup 142}La (2542 keV), {sup 89}Rb (2570 keV), 95Y (2632 keV), {sup 138}Cs (2640 keV) and {sup 95}Y (3576 keV), relative fission rates between different core positions were derived for a fresh sample as well as for a burnt sample with a burn-up of 36 MWd/kg. It was shown that, for both the fresh and burnt fuel samples, the measured fission rate ratios agreed well, i.e. within the statistical uncertainties, with calculation results obtained by Monte Carlo simulations. (authors)

  1. Search for gamma-ray emitting AGN among unidentified Fermi-LAT sources using machine learning algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Doert, Marlene [Technische Universitaet Dortmund (Germany); Ruhr-Universitaet Bochum (Germany); Einecke, Sabrina [Technische Universitaet Dortmund (Germany); Errando, Manel [Barnard College, Columbia University, New York City (United States)

    2015-07-01

    The second Fermi-LAT source catalog (2FGL) is the deepest all-sky survey of the gamma-ray sky currently available to the community. Out of the 1873 catalog sources, 576 remain unassociated. We present a search for active galactic nuclei (AGN) among these unassociated objects, which aims at a reduction of the number of unassociated gamma-ray sources and a more complete characterization of the population of gamma-ray emitting AGN. Our study uses two complimentary machine learning algorithms which are individually trained on the gamma-ray properties of associated 2FGL sources and thereafter applied to the unassociated sample. The intersection of the two methods yields a high-confidence sample of 231 AGN candidate sources. We estimate the performance of the classification by taking inherent differences between the samples of associated and unassociated 2FGL sources into account. A search for infra-red counterparts and first results from follow-up studies in the X-ray band using Swift satellite data for a subset of our AGN candidates are also presented.

  2. The gamma contamination food factor

    International Nuclear Information System (INIS)

    Kukoc, A.H.; Anicin, I.V.; Adzic, P.R.

    1992-01-01

    We suggest that radioactive food contamination, as determined solely by a quantitative gamma-ray spectroscopic measurement, may, apart from the total activity per unit mass, be for quick reference conveniently characterized by another single figure which we call the ''Gamma Contamination Food Factor'' (GCFF). This factor may be defined as the ratio of the total specific activity of gamma-ray-emitting radionuclides in the food sample (except that of 40 K) to the specific activity of 40 K either in the sample itself or in an ''average man''. We discuss briefly the meaning and advantages of these definitions. (author)

  3. High-sensitivity gamma spectroscopy for extended sources. Application to activity measurements on the human body, on glass, and on soil

    International Nuclear Information System (INIS)

    Jouve, B.

    1962-01-01

    The measurement and location by gamma spectroscopy of human body internal contaminations at maximum permissible levels, and, in certain cases, at lower activities such as that due to 40 K was investigated. The characteristics of the high-sensitivity apparatus used are given, and several assemblies using large-volume NaI(Tl) scintillators are described. The relatively light shielding required for natural radioactivity permitted construction of mobile assembly. Conditions of use are described, and the results are given. All gamma emitting elements were measured in 15 min at levels lower than the tolerance dose. Gamma spectroscopy was also used to determine fission products in the earth and to study radioactive elements in the presence of other emitters. (author) [fr

  4. Tables of nuclear constants for gamma activation analysis

    International Nuclear Information System (INIS)

    Randa, Z.; Kreisinger, F.

    1980-01-01

    The tables of photonuclear reactions presented, designed for gamma activation analysis, list accurate data on energy of photons emitted by radionuclides, gamma line intensity, half-lives, photonuclear reactions, or the genetic relationship leading to the formation of the given radionuclide together with the respective reaction thresholds. They also list natural isotopic occurrence of the individual target nuclides. The tables are arranged by increasing atomic numbers of newly formed radionuclides and by increasing gamma energies. (B.S.)

  5. An improved in situ method for determining depth distributions of gamma-ray emitting radionuclides

    International Nuclear Information System (INIS)

    Benke, R.R.; Kearfott, K.J.

    2001-01-01

    In situ gamma-ray spectrometry determines the quantities of radionuclides in some medium with a portable detector. The main limitation of in situ gamma-ray spectrometry lies in determining the depth distribution of radionuclides. This limitation is addressed by developing an improved in situ method for determining the depth distributions of gamma-ray emitting radionuclides in large area sources. This paper implements a unique collimator design with conventional radiation detection equipment. Cylindrically symmetric collimators were fabricated to allow only those gamma-rays emitted from a selected range of polar angles (measured off the detector axis) to be detected. Positioned with its axis normal to surface of the media, each collimator enables the detection of gamma-rays emitted from a different range of polar angles and preferential depths. Previous in situ methods require a priori knowledge of the depth distribution shape. However, the absolute method presented in this paper determines the depth distribution as a histogram and does not rely on such assumptions. Other advantages over previous in situ methods are that this method only requires a single gamma-ray emission, provides more detailed depth information, and offers a superior ability for characterizing complex depth distributions. Collimated spectrometer measurements of buried area sources demonstrated the ability of the method to yield accurate depth information. Based on the results of actual measurements, this method increases the potential of in situ gamma-ray spectrometry as an independent characterization tool in situations with unknown radionuclide depth distributions

  6. Determination of {gamma}-rays emitting radionuclides in surface water: application of a quantitative biosensing method

    Energy Technology Data Exchange (ETDEWEB)

    Wolterbeek, H Th; Van der Meer, A. J. G. M. [Delft University of Technology, Interfaculty Reactor Institute, Mekelweg 15, 2629 JB Delft (Netherlands)

    1995-12-01

    A quantitative biosensing method has been developed for the determination of {gamma}-rays emitting radionuclides in surface water. The method is based on the concept that at equilibrium the specific radioactivity in the biosensor is equal to the specific radioactivity in water. The method consists of the measurement of both the radionuclide and the related stable isotope (element) in the biosensor and the determination of the element in water. This three-way analysis eliminates problems such as unpredictable biosensor behaviour, effects of water elemental composition or further abiotic parameters on accumulation levels: what remains is the generally high enrichment (bioaccumulation factor BCF) of elements and radionuclides in the biosensor material. Using water plants, the method is shown to be three to five orders of magnitude more sensitive than the direct analysis of water. (author)

  7. Nuclear energy - Waste-packages activity measurement - Part.1: high-resolution gamma spectrometry in integral mode with open geometry

    International Nuclear Information System (INIS)

    2004-01-01

    ISO 14850:2004 describes a procedure for measurements of gamma-emitting radionuclide activity in homogeneous objects such as unconditioned waste (including process waste, dismantling waste, etc.), waste conditioned in various matrices (bitumen, hydraulic binder, thermosetting resins, etc.), notably in the form of 100 L, 200 L, 400 L or 800 L drums, and test specimens or samples, (vitrified waste), and waste packaged in a container, notably technological waste. It also specifies the calibration of the gamma spectrometry chain. The gamma energies used generally range from 0,05 MeV to 3 MeV. (authors)

  8. ''Strong gammas''. List of strong gamma-rays emitted from radionuclides. Documentation of the PC diskette

    International Nuclear Information System (INIS)

    Ichimiya, T.; Narita, T.; Kitao, K.

    1994-01-01

    The PC diskette containing the ''List of strong gamma-rays emitted from radionuclides'' as published by T. Narita et al. in the report JAERI-M-94-059, March 1994, is described. The diskette is available from the IAEA Nuclear Data Section, costfree, upon request. (author)

  9. Decay Curves and Half-Lives of Gamma-Emitting States from a Study of Prompt Fission Gamma Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Albinsson, H [Chalmers Univ. of Technology, Goeteborg (SE)

    1971-04-15

    Measurements were made on the time distributions of the prompt gamma radiation emitted from fragments in the thermal-neutron induced fission of 235U. The gamma radiation emitted during different time intervals after the fission event was studied with the help of a collimator, the position of which was changed along the path of the fragments. In this way decay curves were obtained from which half-lives could be estimated. Time components with half-lives of 7.5, 18 and 60 ps were found and their relative intensities were calculated. Half-lives and associated intensities are in good agreement with earlier data from uranium and californium fission. Problems involved in this type of study are discussed. The collimator technique has proved to be effective for determination of half lives down to less than 10 ps

  10. Gamma emitting radionuclides of the Test Reactor Area leaching ponds

    International Nuclear Information System (INIS)

    Millard, J.B.; Whicker, F.W.; Markham, O.D.

    1978-01-01

    Radioactive leaching ponds adjacent to the Test Reactor Area (TRA) located on the Idaho National Engineering Laboratory (INEL) Site were investigated to determine the seasonal distribution and ecological behavior of gamma emitting radionuclides. The potential hazards to man and the environment were considered through the biological export of radioactive materials from the ponds. Both biotic and abiotic pond compartments were sampled. Fall and winter biomass estimates showed that benthic periphyton comprised 52%, macrophytes and littoral vegetation 35%, and seston 10% of the total for all biotic compartments. Concentrations and concentration factors (CFs) for fall and winter are presented for Cr-51, Co-60, Zr-95, I-131, Cs-137, Ba-140, and Ce-141. Concentrations and CFs ranged over seven orders of magnitude for the various nuclides and compartments. Seston and zooplankton had the highest concentrations followed by periphyton, sediment, macrophytes, littoral plants, willow, and filtered water. Arthropods had variable concentrations and CFs. Significant seasonal differences were observed for concentrations and CFs in seston, macrophytes, and littoral vegetation. A compartmental inventory of total gamma emitting activity accounted for 254 Ci (9.25 TBq) of the 731 Ci (24.8 TBq) estimated to remain in the ponds at the time of sampling. Filtered water and surface sediments contained 99% of the total radioactivity, while periphyton and seston had most of the remaining 1%. An estimate of the avian export rate of radioactivity from the TRA ponds showed that potentially harvestable mourning doves had the lowest rate with 0.02 μCi/y. External tissues of migratory waterfowl were found to contribute 90% of the total exported activity for all birds. The total avian export rate was estimated to be 1350 μCi/y during 1975

  11. Beta activity measurements in high, variable gamma backgrounds

    International Nuclear Information System (INIS)

    Stanga, D.; Sandu, E.; Craciun, L.

    1997-01-01

    In many cases beta activity measurements must be performed in high and variable gamma backgrounds. In such instances it is necessary to use well-shielded detectors but this technique is limited to laboratory equipment and frequently insufficient. In order to perform in a simple manner beta activity measurements in high and variable backgrounds a software-aided counting technique have been developed and a counting system have been constructed. This technique combines the different counting techniques with traditional method of successive measurement of the sample and background. The counting system is based on a programmable multi-scaler which is endowed with appropriate software and allow all operations to be performed via keyboard in an interactive fashion. Two large - area proportional detectors were selected in order to have the same background and the same gamma response within 5%. A program has been developed for the counting data analysis and beta activity computing. The software-aided counting technique has been implemented for beta activity measurement in high and variable backgrounds. (authors)

  12. Modulated High-Energy Gamma-Ray Emission from the Micro-quasar Cygnus X-3

    International Nuclear Information System (INIS)

    Abdo, A.A.; Cheung, C.C.; Dermer, C.D.; Grove, J.E.; Johnson, W.N.; Lovellette, M.N.; Makeev, A.; Ray, P.S.; Strickman, M.S.; Wood, K.S.; Abdo, A.A.; Cheung, C.C.; Ackermann, M.; Ajello, M.; Bechtol, K.; Berenji, B.; Blandford, R.D.; Bloom, E.D.; Borgland, A.W.; Cameron, R.A.; Chiang, J.; Claus, R.; Digel, S.W.; Silva, E.D.E.; Drell, P.S.; Dubois, R.; Focke, W.B.; Glanzman, T.; Godfrey, G.; Hayashida, M.; Johannesson, G.; Johnson, A.S.; Kamae, T.; Kocian, M.L.; Lande, J.; Madejski, G.M.; Michelson, P.F.; Mitthumsiri, W.; Monzani, M.E.; Moskalenko, I.V.; Murgia, S.; Nolan, P.L.; Paneque, D.; Reimer, A.; Reimer, O.; Rochester, L.S.; Romani, R.W.; Tanaka, T.; Thayer, J.B.; Tramacere, A.; Uchiyama, Y.; Usher, T.L.; Waite, A.P.; Wang, P.; Ackermann, M.; Ajello, M.; Bechtol, K.; Berenji, B.; Blandford, R.D.; Bloom, E.D.; Borgland, A.W.; Cameron, R.A.; Chiang, J.; Claus, R.; Digel, S.W.; Silva, E.D.E.; Drell, P.S.; Dubois, R.; Focke, W.B.; Glanzman, T.; Godfrey, G.; Hayashida, M.; Johannesson, G.; Johnson, A.S.; Kamae, T.; Kocian, M.L.; Lande, J.; Madejski, G.M.; Michelson, P.F.; Mitthumsiri, W.; Monzani, M.E.; Moskalenko, I.V.; Murgia, S.; Nolan, P.L.; Paneque, D.; Reimer, A.; Reimer, O.; Rochester, L.S.; Romani, R.W.; Tanaka, T.; Thayer, J.B.; Tramacere, A.; Uchiyama, Y.; Usher, T.L.; Waite, A.P.; Wang, P.; Axelsson, M.; Hjalmarsdotter, L.; Axelsson, M.; Conrad, J.; Hjalmarsdotter, L.; Jackson, M.S.; Meurer, C.; Ryde, F.; Ylinen, T.; Baldini, L.; Bellazzini, R.; Brez, A.; Kuss, M.; Latronico, L.; Omodei, N.; Pesce-Rollins, M.; Razzano, M.; Sgro, C.; Ballet, J.; Casandjian, J.M.; Chaty, S.; Corbel, S.; Grenier, I.A.; Koerding, E.; Rodriguez, J.; Starck, J.L.; Tibaldo, L.

    2009-01-01

    Micro-quasars are accreting black holes or neutron stars in binary systems with associated relativistic jets. Despite their frequent outburst activity, they have never been unambiguously detected emitting high-energy gamma rays. The Fermi Large Area Telescope (LAT) has detected a variable high-energy source coinciding with the position of the x-ray binary and micro-quasar Cygnus X-3. Its identification with Cygnus X-3 is secured by the detection of its orbital period in gamma rays, as well as the correlation of the LAT flux with radio emission from the relativistic jets of Cygnus X-3. The gamma-ray emission probably originates from within the binary system, opening new areas in which to study the formation of relativistic jets. (authors)

  13. Prompt gamma neutron activation analysis

    International Nuclear Information System (INIS)

    Goswami, A.

    2003-01-01

    Prompt gamma neutron activation analysis (PGNAA) is a technique for the analysis of elements present in solid, liquid and gaseous samples by measuring the capture gamma rays emitted from the sample during neutron irradiation. The technique is complementary to conventional neutron activation analysis (NAA) as it can be used in number of cases where NAA fails. Though the technique was first used in sixties, the advantage of the technique was first highlighted by Lindstrom and Anderson. PGNAA is increasingly being used as a rapid, instrumental, nondestructive and multielement analysis technique. A monograph and several excellent reviews on this topic have appeared recently. In this review, an attempt has been made to bring out the essential aspects of the technique, experimental arrangement and instrumentation involved, and areas of application. Some of the results will also be presented

  14. Modeling the Broad-Band Emission from the Gamma-Ray Emitting Narrow-Line Seyfert-1 Galaxies 1H 0323+342 and B2 0954+25A

    International Nuclear Information System (INIS)

    Arrieta-Lobo, Maialen; Boisson, Catherine; Zech, Andreas

    2017-01-01

    Prior to the Fermi-LAT era, only two classes of Active Galactic Nuclei (AGN) were thought to harbor relativistic jets that radiate up to gamma-ray energies: blazars and radio galaxies. The detection of variable gamma-ray emission from Narrow Line Seyfert 1 (NLSy1) galaxies has put them on the spotlight as a new class of gamma-ray emitting AGN. In this respect, gamma-ray emitting NLSy1s seem to be situated between blazars (dominated by non-thermal emission) and Seyferts (accretion disc dominated). In this work, we model the Spectral Energy Distribution (SED) of two gamma-loud NLSy1s, 1H 0323+342 and B2 0954+25A, during quiescent and flaring episodes via a multi-component radiative model that features a relativistic jet and external photon fields from the torus, disc, corona and Broad Line Region (BLR). We find that the interpretation of the high-energy emission of jetted NLSy1s requires taking into account Inverse Compton emission from particles in the relativistic jet that interact with external photon fields. Minimal changes are applied to the model parameters to transition from average to flaring states. In this scenario, the observed variability is explained mainly by means of changes in the jet density and Doppler factor.

  15. Modeling the Broad-Band Emission from the Gamma-Ray Emitting Narrow-Line Seyfert-1 Galaxies 1H 0323+342 and B2 0954+25A

    Energy Technology Data Exchange (ETDEWEB)

    Arrieta-Lobo, Maialen; Boisson, Catherine; Zech, Andreas, E-mail: maialen.arrieta@obspm.fr [Laboratoire Univers et Theories, Observatoire de Paris, CNRS, Université Paris-Diderot, PSL Research University, Meudon (France)

    2017-12-08

    Prior to the Fermi-LAT era, only two classes of Active Galactic Nuclei (AGN) were thought to harbor relativistic jets that radiate up to gamma-ray energies: blazars and radio galaxies. The detection of variable gamma-ray emission from Narrow Line Seyfert 1 (NLSy1) galaxies has put them on the spotlight as a new class of gamma-ray emitting AGN. In this respect, gamma-ray emitting NLSy1s seem to be situated between blazars (dominated by non-thermal emission) and Seyferts (accretion disc dominated). In this work, we model the Spectral Energy Distribution (SED) of two gamma-loud NLSy1s, 1H 0323+342 and B2 0954+25A, during quiescent and flaring episodes via a multi-component radiative model that features a relativistic jet and external photon fields from the torus, disc, corona and Broad Line Region (BLR). We find that the interpretation of the high-energy emission of jetted NLSy1s requires taking into account Inverse Compton emission from particles in the relativistic jet that interact with external photon fields. Minimal changes are applied to the model parameters to transition from average to flaring states. In this scenario, the observed variability is explained mainly by means of changes in the jet density and Doppler factor.

  16. Pulmonary Immune-Compartment-Specific Interferon Gamma Responses in HIV-Infected Individuals with Active Tuberculosis (TB in an Area of High TB Prevalence

    Directory of Open Access Journals (Sweden)

    S. Buldeo

    2012-01-01

    Full Text Available There is a paucity of data on the pulmonary immune-compartment interferon gamma (IFNγ response to M. tuberculosis, particularly in settings of high tuberculosis (TB prevalence and in HIV-coinfected individuals. This data is necessary to understand the diagnostic potential of commercially available interferon gamma release assays (IGRAs in both the pulmonary immune-compartment and peripheral blood. We used intracellular cytokine staining by flow cytometry to assess the IFNγ response to purified protein derivative (PPD and early secretory antigen 6 (ESAT6 in induced sputa (ISp and blood samples from HIV-infected, smear-negative, TB suspects. We found that individuals with active TB disease produced significantly less IFNγ in response to PPD in their induced sputa samples than individuals with non-active TB (control group. This difference was not reflected in the peripheral blood, even within the CD27− CD4+ memory T lymphocyte population. These findings suggest that progression to active TB disease may be associated with the loss of IFNγ secretion at the site of primary infection. Our findings highlight the importance of studying pulmonary immune-compartment M. tuberculosis specific responses to elucidate IFNγ secretion across the spectrum of TB disease.

  17. Detecting special nuclear materials in suspect containers using high-energy gamma rays emitted by fission products

    Science.gov (United States)

    Norman, Eric B [Oakland, CA; Prussin, Stanley G [Kensington, CA

    2009-01-27

    A method and a system for detecting the presence of special nuclear materials in a suspect container. The system and its method include irradiating the suspect container with a beam of neutrons, so as to induce a thermal fission in a portion of the special nuclear materials, detecting the gamma rays that are emitted from the fission products formed by the thermal fission, to produce a detector signal, comparing the detector signal with a threshold value to form a comparison, and detecting the presence of the special nuclear materials using the comparison.

  18. Radium equivalent activity of building materials and gamma ray dose rates in ordinary houses of Sao Paulo, Brazil

    International Nuclear Information System (INIS)

    Campos, M.P.; Pecequilo, B.R.S.

    1994-01-01

    The external radiation exposure from natural radioactivity represents, approximately, 50% of the average annual dose caused to the human body by all natural and artificial radiation sources. Natural radioactivity in building materials is the most important source of external radiation exposure in dwellings because of the gamma rays emitted from potassium 40 and member of the uranium 238 and thorium 232 decay chains. Concrete is one of the most potential sources of elevated radiation exposure, however, little is known about the natural radioactivity of Brazilian construction materials. A study to predict the exposure rates of several ordinary houses built almost of concrete, consisting of 38 samples of 6 different materials was conducted by using high resolution gamma-ray spectrometry. The radium equivalent activity was calculated for all 38 samples in order to compare the specific activities of the construction materials containing different amounts of radium, thorium, and potassium. The effective dose rate due to the indoor gamma radiation from the building materials was performed following the 1988 UNSCEAR procedures

  19. Standard test method for nondestructive assay of radioactive material by tomographic gamma scanning

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method describes the nondestructive assay (NDA) of gamma ray emitting radionuclides inside containers using tomographic gamma scanning (TGS). High resolution gamma ray spectroscopy is used to detect and quantify the radionuclides of interest. The attenuation of an external gamma ray transmission source is used to correct the measurement of the emission gamma rays from radionuclides to arrive at a quantitative determination of the radionuclides present in the item. 1.2 The TGS technique covered by the test method may be used to assay scrap or waste material in cans or drums in the 1 to 500 litre volume range. Other items may be assayed as well. 1.3 The test method will cover two implementations of the TGS procedure: (1) Isotope Specific Calibration that uses standards of known radionuclide masses (or activities) to determine system response in a mass (or activity) versus corrected count rate calibration, that applies to only those specific radionuclides for which it is calibrated, and (2) Respo...

  20. Energy–angle correlation of neutrons and gamma-rays emitted from an HEU source

    Energy Technology Data Exchange (ETDEWEB)

    Miloshevsky, G., E-mail: gennady@purdue.edu; Hassanein, A.

    2014-06-01

    Special Nuclear Materials (SNM) yield very unique fission signatures, namely correlated neutrons and gamma-rays. A major challenge is not only to detect, but also to rapidly identify and recognize SNM with certainty. Accounting for particle multiplicity and correlations is one of standard ways to detect SNM. However, many parameter data such as joint distributions of energy, angle, lifetime, and multiplicity of neutrons and gamma-rays can lead to better recognition of SNM signatures in the background radiation noise. These joint distributions are not well understood. The Monte Carlo simulations of the transport of neutrons and gamma-rays produced from spontaneous and interrogation-induced fission of SNM are carried out using the developed MONSOL computer code. The energy spectra of neutrons and gamma-rays from a bare Highly Enriched Uranium (HEU) source are investigated. The energy spectrum of gamma-rays shows spectral lines by which HEU isotopes can be identified, while those of neutrons do not show any characteristic lines. The joint probability density function (JPDF) of the energy–angle association of neutrons and gamma-rays is constructed. Marginal probability density functions (MPDFs) of energy and angle are derived from JPDF. A probabilistic model is developed for the analysis of JPDF and MPDFs. This probabilistic model is used to evaluate mean values, standard deviations, covariance and correlation between the energy and angle of neutrons and gamma-rays emitted from the HEU source. For both neutrons and gamma-rays, it is found that the energy–angle variables are only weakly correlated.

  1. High-efficiency white organic light-emitting diodes using thermally activated delayed fluorescence

    International Nuclear Information System (INIS)

    Nishide, Jun-ichi; Hiraga, Yasuhide; Nakanotani, Hajime; Adachi, Chihaya

    2014-01-01

    White organic light-emitting diodes (WOLEDs) have attracted much attention recently, aimed for next-generation lighting sources because of their high potential to realize high electroluminescence efficiency, flexibility, and low-cost manufacture. Here, we demonstrate high-efficiency WOLED using red, green, and blue thermally activated delayed fluorescence materials as emissive dopants to generate white electroluminescence. The WOLED has a maximum external quantum efficiency of over 17% with Commission Internationale de l'Eclairage coordinates of (0.30, 0.38).

  2. High-energy gamma-ray emission in compact binaries

    International Nuclear Information System (INIS)

    Cerutti, Benoit

    2010-01-01

    Four gamma-ray sources have been associated with binary systems in our Galaxy: the micro-quasar Cygnus X-3 and the gamma-ray binaries LS I +61 degrees 303, LS 5039 and PSR B1259-63. These systems are composed of a massive companion star and a compact object of unknown nature, except in PSR B1259-63 where there is a young pulsar. I propose a comprehensive theoretical model for the high-energy gamma-ray emission and variability in gamma-ray emitting binaries. In this model, the high-energy radiation is produced by inverse Compton scattering of stellar photons on ultra-relativistic electron-positron pairs injected by a young pulsar in gamma-ray binaries and in a relativistic jet in micro-quasars. Considering anisotropic inverse Compton scattering, pair production and pair cascade emission, the TeV gamma-ray emission is well explained in LS 5039. Nevertheless, this model cannot account for the gamma-ray emission in LS I +61 degrees 303 and PSR B1259-63. Other processes should dominate in these complex systems. In Cygnus X-3, the gamma-ray radiation is convincingly reproduced by Doppler-boosted Compton emission of pairs in a relativistic jet. Gamma-ray binaries and micro-quasars provide a novel environment for the study of pulsar winds and relativistic jets at very small spatial scales. (author)

  3. Synthesis of high specific activity carbon-11 labeled tracers for neuroreceptor studies

    International Nuclear Information System (INIS)

    Dannals, R.F.; Ravert, H.T.; Wilson, A.A.; Wagner, H.N. Jr; Johns Hopkins Medical Institutions, Baltimore, MD

    1989-01-01

    The use of short-lived positron-emitting radiotracers together with positron emission tomography (PET) has allowed scientists to acquire previously inaccessible information regarding problems in physiology, biochemistry, and pharmacology in the living human body. In the past five years, successes in the application of PET to the non-invasive determination of the spatial distribution and regional concentration of a variety of neurotransmitter binding sites within the living brain often followed the successful selections and syntheses of appropriately radiolabeled ligands. This presentation concentrates on the synthesis of these high specific activity radiotracers for neuroreceptor PET studies labeled specifically with carbon-11. (author). 15 refs.; 1 fig

  4. Very-high-energy gamma rays from a distant quasar: how transparent is the universe?

    Science.gov (United States)

    Albert, J; Aliu, E; Anderhub, H; Antonelli, L A; Antoranz, P; Backes, M; Baixeras, C; Barrio, J A; Bartko, H; Bastieri, D; Becker, J K; Bednarek, W; Berger, K; Bernardini, E; Bigongiari, C; Biland, A; Bock, R K; Bonnoli, G; Bordas, P; Bosch-Ramon, V; Bretz, T; Britvitch, I; Camara, M; Carmona, E; Chilingarian, A; Commichau, S; Contreras, J L; Cortina, J; Costado, M T; Covino, S; Curtef, V; Dazzi, F; De Angelis, A; De Cea Del Pozo, E; de Los Reyes, R; De Lotto, B; De Maria, M; De Sabata, F; Mendez, C Delgado; Dominguez, A; Dorner, D; Doro, M; Errando, M; Fagiolini, M; Ferenc, D; Fernández, E; Firpo, R; Fonseca, M V; Font, L; Galante, N; López, R J García; Garczarczyk, M; Gaug, M; Goebel, F; Hayashida, M; Herrero, A; Höhne, D; Hose, J; Hsu, C C; Huber, S; Jogler, T; Kneiske, T M; Kranich, D; La Barbera, A; Laille, A; Leonardo, E; Lindfors, E; Lombardi, S; Longo, F; López, M; Lorenz, E; Majumdar, P; Maneva, G; Mankuzhiyil, N; Mannheim, K; Maraschi, L; Mariotti, M; Martínez, M; Mazin, D; Meucci, M; Meyer, M; Miranda, J M; Mirzoyan, R; Mizobuchi, S; Moles, M; Moralejo, A; Nieto, D; Nilsson, K; Ninkovic, J; Otte, N; Oya, I; Panniello, M; Paoletti, R; Paredes, J M; Pasanen, M; Pascoli, D; Pauss, F; Pegna, R G; Perez-Torres, M A; Persic, M; Peruzzo, L; Piccioli, A; Prada, F; Prandini, E; Puchades, N; Raymers, A; Rhode, W; Ribó, M; Rico, J; Rissi, M; Robert, A; Rügamer, S; Saggion, A; Saito, T Y; Salvati, M; Sanchez-Conde, M; Sartori, P; Satalecka, K; Scalzotto, V; Scapin, V; Schmitt, R; Schweizer, T; Shayduk, M; Shinozaki, K; Shore, S N; Sidro, N; Sierpowska-Bartosik, A; Sillanpää, A; Sobczynska, D; Spanier, F; Stamerra, A; Stark, L S; Takalo, L; Tavecchio, F; Temnikov, P; Tescaro, D; Teshima, M; Tluczykont, M; Torres, D F; Turini, N; Vankov, H; Venturini, A; Vitale, V; Wagner, R M; Wittek, W; Zabalza, V; Zandanel, F; Zanin, R; Zapatero, J

    2008-06-27

    The atmospheric Cherenkov gamma-ray telescope MAGIC, designed for a low-energy threshold, has detected very-high-energy gamma rays from a giant flare of the distant Quasi-Stellar Radio Source (in short: radio quasar) 3C 279, at a distance of more than 5 billion light-years (a redshift of 0.536). No quasar has been observed previously in very-high-energy gamma radiation, and this is also the most distant object detected emitting gamma rays above 50 gigaelectron volts. Because high-energy gamma rays may be stopped by interacting with the diffuse background light in the universe, the observations by MAGIC imply a low amount for such light, consistent with that known from galaxy counts.

  5. The effect of gamma radiation on the properties of activated carbon cloth

    Directory of Open Access Journals (Sweden)

    DANIJELA R. SEKULIĆ

    2009-09-01

    Full Text Available Activated carbon cloth dressing is an appropriate wound healing material due to its biocompatibility and adsorption characteristics. The in-fluence of gamma radiation as a sterilization process on the adsorption and mechanical properties of activated carbon cloth was investigated. The specific surface area, micropore volume, pore size distribution, surface chemistry as well as the breaking load of activated carbon cloth before and after gamma radiation were examined. Characterization by nitrogen adsorption showed that the activated carbon cloth was a microporous material with a high specific surface area and micropores smaller than 1 nm. Gamma radiation decreased the specific surface area and micropore volume but increased the pore width. The sterilization process changed the surface chemistry quantitatively, but not qualitatively. In addition, the breaking load decreased but without any influence considering the further application of this material.

  6. Quantitative portable gamma spectroscopy sample analysis for non-standard sample geometries

    International Nuclear Information System (INIS)

    Enghauser, M.W.; Ebara, S.B.

    1997-01-01

    Utilizing a portable spectroscopy system, a quantitative method for analysis of samples containing a mixture of fission and activation products in nonstandard geometries was developed. The method can be used with various sample and shielding configurations where analysis on a laboratory based gamma spectroscopy system is impractical. The portable gamma spectroscopy method involves calibration of the detector and modeling of the sample and shielding to identify and quantify the radionuclides present in the sample. The method utilizes the intrinsic efficiency of the detector and the unattenuated gamma fluence rate at the detector surface per unit activity from the sample to calculate the nuclide activity and Minimum Detectable Activity (MDA). For a complex geometry, a computer code written for shielding applications (MICROSHIELD) is utilized to determine the unattenuated gamma fluence rate per unit activity at the detector surface. Lastly, the method is only applicable to nuclides which emit gamma rays and cannot be used for pure beta emitters. In addition, if sample self absorption and shielding is significant, the attenuation will result in high MDA's for nuclides which solely emit low energy gamma rays. The following presents the analysis technique and presents verification results demonstrating the accuracy of the method

  7. A study of gamma-emitting radionuclides present into the sediments and algae of the ''Baie de l'Orne'' (Central Normandy Coast) collecting during the years 1980 - 1982

    International Nuclear Information System (INIS)

    Lepy, M.C.

    1982-01-01

    The present status of some environmental effects of existing sources of gamma-emitting radionuclides, along the Central part of the Normandy Coast (Calvados shores and river Orne mouth) was determined. A systematic study was made on the behaviour of the marine sediments and brown alga 'Laminaria digitata' with regard to their properties as indicators of radioactive contamination. Marine sediments were collected into the river Orne at fixed locations and into the sea in and around the estuary from 1977 to 1982. Algae samples were picked up along the coast from 1980 to 1982, mostly on the western part of the Orne estuary. Dosimetry techniques employed have produced accurate and reliable results, despite the very low levels of activity involved. Gamma-emitting radionuclides present in the environment (chiefly 106 Ru, 137 Cs, 95 Zr) were identified and measured. Their behaviour into the marine sediments and into Laminaria Digitata were determined. This study provides evidence on the presence of numerous gamma-emitting radionuclides into the marine environment of the Central part of the Normandy coast, but, altogether with very low levels of radioactivity [fr

  8. Specific or nonspecific? Evaluation of band, baseline, and cognitive specificity of sensorimotor rhythm- and gamma-based neurofeedback.

    Science.gov (United States)

    Kober, Silvia Erika; Witte, Matthias; Neuper, Christa; Wood, Guilherme

    2017-10-01

    Neurofeedback (NF) is often criticized because of the lack of empirical evidence of its specificity. Our present study thus focused on the specificity of NF on three levels: band specificity, cognitive specificity, and baseline specificity. Ten healthy middle-aged individuals performed ten sessions of SMR (sensorimotor rhythm, 12-15Hz) NF training. A second group (N=10) received feedback of a narrow gamma band (40-43Hz). Effects of NF on EEG resting measurements (tonic EEG) and cognitive functions (memory, intelligence) were evaluated using a pre-post design. Both training groups were able to linearly increase the target training frequencies (either SMR or gamma), indicating the trainability of these EEG frequencies. Both NF training protocols led to nonspecific changes in other frequency bands during NF training. While SMR NF only led to concomitant changes in slower frequencies, gamma training affected nearly the whole power spectrum. SMR NF specifically improved memory functions. Gamma training showed only marginal effects on cognitive functions. SMR power assessed during resting measurements significantly increased after SMR NF training compared to a pre-assessment, indicating specific effects of SMR NF on baseline/tonic EEG. The gamma group did not show any pre-post changes in their EEG resting activity. In conclusion, SMR NF specifically affects cognitive functions (cognitive specificity) and tonic EEG (baseline specificity), while increasing SMR during NF training nonspecifically affects slower EEG frequencies as well (band non-specificity). Gamma NF was associated with nonspecific effects on the EEG power spectrum during training, which did not lead to considerable changes in cognitive functions or baseline EEG activity. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Prediction and design of efficient exciplex emitters for high-efficiency, thermally activated delayed-fluorescence organic light-emitting diodes.

    Science.gov (United States)

    Liu, Xiao-Ke; Chen, Zhan; Zheng, Cai-Jun; Liu, Chuan-Lin; Lee, Chun-Sing; Li, Fan; Ou, Xue-Mei; Zhang, Xiao-Hong

    2015-04-08

    High-efficiency, thermally activated delayed-fluorescence organic light-emitting diodes based on exciplex emitters are demonstrated. The best device, based on a TAPC:DPTPCz emitter, shows a high external quantum efficiency of 15.4%. Strategies for predicting and designing efficient exciplex emitters are also provided. This approach allow prediction and design of efficient exciplex emitters for achieving high-efficiency organic light-emitting diodes, for future use in displays and lighting applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Limits to the Fraction of High-energy Photon Emitting Gamma-Ray Bursts

    Science.gov (United States)

    Akerlof, Carl W.; Zheng, WeiKang

    2013-02-01

    After almost four years of operation, the two instruments on board the Fermi Gamma-ray Space Telescope have shown that the number of gamma-ray bursts (GRBs) with high-energy photon emission above 100 MeV cannot exceed roughly 9% of the total number of all such events, at least at the present detection limits. In a recent paper, we found that GRBs with photons detected in the Large Area Telescope have a surprisingly broad distribution with respect to the observed event photon number. Extrapolation of our empirical fit to numbers of photons below our previous detection limit suggests that the overall rate of such low flux events could be estimated by standard image co-adding techniques. In this case, we have taken advantage of the excellent angular resolution of the Swift mission to provide accurate reference points for 79 GRB events which have eluded any previous correlations with high-energy photons. We find a small but significant signal in the co-added field. Guided by the extrapolated power-law fit previously obtained for the number distribution of GRBs with higher fluxes, the data suggest that only a small fraction of GRBs are sources of high-energy photons.

  11. LIMITS TO THE FRACTION OF HIGH-ENERGY PHOTON EMITTING GAMMA-RAY BURSTS

    International Nuclear Information System (INIS)

    Akerlof, Carl W.; Zheng, WeiKang

    2013-01-01

    After almost four years of operation, the two instruments on board the Fermi Gamma-ray Space Telescope have shown that the number of gamma-ray bursts (GRBs) with high-energy photon emission above 100 MeV cannot exceed roughly 9% of the total number of all such events, at least at the present detection limits. In a recent paper, we found that GRBs with photons detected in the Large Area Telescope have a surprisingly broad distribution with respect to the observed event photon number. Extrapolation of our empirical fit to numbers of photons below our previous detection limit suggests that the overall rate of such low flux events could be estimated by standard image co-adding techniques. In this case, we have taken advantage of the excellent angular resolution of the Swift mission to provide accurate reference points for 79 GRB events which have eluded any previous correlations with high-energy photons. We find a small but significant signal in the co-added field. Guided by the extrapolated power-law fit previously obtained for the number distribution of GRBs with higher fluxes, the data suggest that only a small fraction of GRBs are sources of high-energy photons.

  12. Spectra of gamma-ray bursts at high energies

    International Nuclear Information System (INIS)

    Matz, S.M.

    1986-01-01

    Between 1980 February and 1983 August the Gamma-Ray Spectrometer (GRS) on the Solar Maximum Mission satellite (SMM) observed 71 gamma-ray bursts. These events form a representative subset of the class of classical gamma-ray bursts. Since their discovery more than 15 years ago, hundreds of gamma-ray bursts have been detected; however, most observations have been limited to an energy range of roughly 30 keV-1 MeV. The large sensitive area and spectral range of the GRS allow, for the first time, an investigation of the high energy (>1 MeV) behavior of a substantial number of gamma-ray bursts. It is found that high-energy emission is seen in a large fraction of all events and that the data are consistent with all bursts emitting to at least 5 MeV with no cut-offs. Further, no burst spectrum measured by GRS has a clear high-energy cut-off. The high-energy emission can be a significant part of the total burst energy on the average about 30% of the observed energy above 30 keV is contained in the >1 MeV photons. The fact that the observations are consistent with the presence of high-energy emission in all events implies a limit on the preferential beaming of high-energy photons, from any mechanism. Single-photon pair-production in a strong magnetic field produces such beaming; assuming that the low-energy emission is isotropic, the data imply an upper limit of 1 x 10 12 G on the typical magnetic field at burst radiation sites

  13. Imaging instrument for positron emitting heavy ion beam injection

    International Nuclear Information System (INIS)

    Llacer, J.; Chatterjee, A.; Jackson, H.C.; Lin, J.C.; Zunzunegui, M.V.

    1978-10-01

    The design and performance of an instrument for the imaging of coincidence annihilation gamma rays emitted from the end point of the trajectories of radioactive high-energy heavy ions is described. The positron-emitting heavy ions are the result of nuclear fragmentation of accelerated heavy ions used in cancer therapy or diagnostic medicine. The instrument constructed is capable of locating the ion beam trajectory end point within 1 mm for an injected activity of 200 nanoCi in a measurement time of 1 sec in some favorable conditions. Limited imaging in three dimensions is also demonstrated

  14. Gamma-ray detection with an UV-enhanced photodiode and scintillation crystals emitting at short wavelengths

    International Nuclear Information System (INIS)

    Johansen, G.A.

    1997-01-01

    A low-noise ion implanted photodiode with high spectral response in the deep blue/UV region has been tested as read-out device for scintillation crystals with matching emission spectra (YAP(Ce), GSO(Ce), BGO and CsI(Tl)). This gamma-ray detector concept is attractive in many industrial applications where compactness, reliability and ambient temperature operation are important. The results show that the amount of detected scintillation light energy falls rapidly off as the wavelength of the scintillation light decreases. It is concluded that the dynamic spectral response of the photodiode, due to increasing carrier collection times, is considerably less than the DC response at short wavelengths. The diode is not useful in pulse mode operation with scintillation crystals emitting at wavelengths below about 400 nm. For read-out of CsI(Tl) with 661.6 keV gamma-radiation, however, the photodiode concept shows better energy resolution (7.1%) than other detectors. (orig.)

  15. 16α-[77Br]bromoestradiol-17β: a high specific-activity, gamma-emitting tracer with uptake in rat uterus and induced mammary tumors

    International Nuclear Information System (INIS)

    Katzenellenbogen, J.A.; Senderoff, S.G.; McElvany, K.D.; O'Brien, H.A. Jr.; Welch, M.J.

    1981-01-01

    16α-[ 77 Br]bromoestradiol-17β (compound 1) has been synthesized by radiobromination of estrone enoldiacetate. Tissue uptake studies performed 1 hr after administration of compound 1 to immature or mature female rats showed uterus-to-blood ratios of 13, with nontarget tissue-to-blood ratios ranging from 0.6 to 2. Co-administration of unlabeled estradiol caused a selective depression in the uterine uptake with no effect on nontarget tissue uptake. In adult animals bearing adenocarcinomas induced by DMBA (7,12-dimethylbenz(a)anthracene), tumor-to-blood ratios of 6.3 were obtained, this uptake also being depressed in animals treated with unlabeled estradiol. The studies demonstrate that compound 1 has suitable binding properties and sufficiently high specific activity so that its uptake in estrogen target tissues in vivo is mediated primarily by the estrogen receptor. Furthermore, they suggest that this compound may be suitable for imaging human breast tumors that contain estrogen receptors

  16. Natural background gamma-ray spectrum. List of gamma-rays ordered in energy from natural radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Ichimiya, Tsutomu [Japan Radioisotope Association, Tokyo (Japan); Narita, Tsutomu; Kitao, Kensuke

    1998-03-01

    A quick index to {gamma}-rays and X-rays from natural radionuclides is presented. In the list, {gamma}-rays are arranged in order of increasing energy. The list also contains {gamma}-rays from radioactive nuclides produced in a germanium detector and its surrounding materials by interaction with cosmic neutrons, as well as direct {gamma}-rays from interaction with the neutrons. Artificial radioactive nuclides emitting {gamma}-rays with same or near energy value as that of the natural {gamma}-rays and X-rays are also listed. In appendix, {gamma}-ray spectra from a rock, uranium ore, thorium, monazite and uraninite and also background spectra obtained with germanium detectors placed in iron or lead shield have been given. The list is designed for use in {gamma}-ray spectroscopy under the conditions of highly natural background, such as in-situ environmental radiation monitoring or low-level activity measurements, with a germanium detector. (author)

  17. Use of delayed gamma rays for active non-destructive assay of {sup 235}U irradiated by pulsed neutron source (plasma focus)

    Energy Technology Data Exchange (ETDEWEB)

    Andola, Sanjay; Niranjan, Ram [Applied Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Kaushik, T.C., E-mail: tckk@barc.gov.in [Applied Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Rout, R.K. [Applied Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Kumar, Ashwani; Paranjape, D.B.; Kumar, Pradeep; Tomar, B.S.; Ramakumar, K.L. [Radioanalytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Gupta, S.C. [Applied Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2014-07-01

    A pulsed neutron source based on plasma focus device has been used for active interrogation and assay of {sup 235}U by monitoring its delayed high energy γ-rays. The method involves irradiation of fissile material by thermal neutrons obtained after moderation of a burst of neutrons emitted upon fusion of deuterium in plasma focus (PF) device. The delayed gamma rays emitted from the fissile material as a consequence of induced fission were detected by a large volume sodium iodide (NaI(Tl)) detector. The detector is coupled to a data acquisition system of 2k input size with 2k ADC conversion gain. Counting was carried out in pulse height analysis mode for time integrated counts up to 100 s while the temporal profile of delayed gamma has been obtained by counting in multichannel scaling mode with dwell time of 50 ms. To avoid the effect of passive (natural) and active (from surrounding materials) backgrounds, counts have been acquired for gamma energy between 3 and 10 MeV. The lower limit of detection of {sup 235}U in the oxide samples with this set-up is estimated to be 14 mg.

  18. Absolute peak detection efficiencies of a Ge(Li) detector for high gamma-ray energies

    International Nuclear Information System (INIS)

    Katagiri, Masaki

    1985-11-01

    Absolute peak detection efficiencies of a Ge(Li) detector for gamma-rays of 3.5 MeV to 12 MeV were measured using four (p,γ) reactions and a (n,γ) reaction. Two-line-method was used to obtaine peak detection efficiencies. The efficiencies with the both cases are agreed very well. Utilization of (n,γ) reaction is, therefore, effective for measuring these efficiencies, because high energy gamma-rays can be generated easily by using a neutron source. These results were applied to calibration of a gamma-ray standard source, emitting 6.13 MeV gamma-rays, and of intensities of 56 Co standard gamma-ray source. (author)

  19. Correcting the effects of the matrix using capture gamma-ray spectrometry: Application to measurement by Active Neutron Interrogation; Correction des effets de matrice par spectrometrie des rayonnements gamma de capture: Application a la mesure par Interrogation Neutronique Active (I.N.A.)

    Energy Technology Data Exchange (ETDEWEB)

    Baudry, G.

    2003-11-15

    In the field of the measurement of low masses of fissile material ({sup 235}U, {sup 239}Pu, {sup 241}Pu) in radioactive waste drums, the Active Neutron Interrogation is a non-destructive method achieving good results. It does however remain reliant upon uncertainties related to the matrix effects on interrogation and fission neutrons. The aim of this thesis is to develop a correction method able to take into account these matrix effects by quantifying the amount of absorbent materials (chlorine and hydrogen) in a 118- liter homogeneous matrix. The main idea is to use the gamma-ray spectrometry of gamma emitted by neutron captures to identify and quantify the composition of the matrix. An indicator from its chlorine content is then deduced in order to choose the calibration coefficient which best represents the real composition of the matrix. This document firstly presents the needs of control and characterization of radioactive objects, and the means used in the field of nuclear measurement. Emphases is put in particular on the Active Neutron Interrogation method. The matrices of interest are those made of light technological waste (density {<=} 0,4 g/cm{sup 3}) containing hydrogenated and chlorinated materials. The advantages of gamma-rays emitted by neutron captures for the determination of a chlorine content indicator of the matrices and the principles of the correction method are then explained. Measurements have been firstly realized with an existing Neutron Interrogation device (PROMETHEE 6). Such measurements have proven its inadequacy: no signal from the matrix hydrogen was detected, due to an intense signal from the polyethylene contained in some cell elements. Moreover, the matrix chlorine content appeared difficult to be measured. A new and specific device, named REGAIN and dedicated to active gamma-rays spectrometry, was defined with the Monte-Carlo N-Particle (MCNP) code. The experiments conducted with this new device made it possible to detect the

  20. Highly efficient exciplex organic light-emitting diodes using thermally activated delayed fluorescent emitters as donor and acceptor materials

    Science.gov (United States)

    Jeon, Sang Kyu; Yook, Kyoung Soo; Lee, Jun Yeob

    2016-06-01

    Highly efficient exciplex type organic light-emitting diodes were developed using thermally activated delayed fluorescent emitters as donors and acceptors of an exciplex. Blue emitting bis[4-(9,9-dimethyl-9,10-dihydroacridine)phenyl]sulfone (DMAC-DPS) was a donor and 9,9‧-(5-(4,6-diphenyl-1,3,5-triazin-2-yl)-1,3-phenylene)bis(9H-carbazole) (DDCzTrz) and 9,9‧,9″-(5-(4,6-diphenyl-1,3,5-triazin-2-yl)benzene-1,2,3-triyl)tris(9H-carbazole) (TCzTrz) were acceptor materials. The exciplexes of DMAC-DPS:TCzTrz and DMAC-DPS:DDCzTrz resulted in high photoluminescence quantum yield and high quantum efficiency in the green exciplex organic light-emitting diodes. High quantum efficiencies of 13.4% and 15.3% were obtained in the DMAC-DPS:DDCzTrz and DMAC-DPS:TCzTrz exciplex devices.

  1. Alpha-crystallins are involved in specific interactions with the murine gamma D/E/F-crystallin-encoding gene.

    Science.gov (United States)

    Pietrowski, D; Durante, M J; Liebstein, A; Schmitt-John, T; Werner, T; Graw, J

    1994-07-08

    The promoter of the murine gamma E-crystallin (gamma E-Cry) encoding gene (gamma E-cry) was analyzed for specific interactions with lenticular proteins in a gel-retardation assay. A 21-bp fragment immediately downstream of the transcription initiation site (DOTIS) is demonstrated to be responsible for specific interactions with lens extracts. The DOTIS-binding protein(s) accept only the sense DNA strand as target; anti-sense or double-stranded DNA do not interact with these proteins. The DOTIS sequence element is highly conserved among the murine gamma D-, gamma E- and gamma F-cry and is present at comparable positions in the orthologous rat genes. Only a weak or even no protein-binding activity is observed if a few particular bases are changed, as in the rat gamma A-, gamma C- and gamma E-cry elements. DOTIS-binding proteins were found in commercially available bovine alpha-Cry preparations. The essential participation of alpha-Cry in the DNA-binding protein complex was confirmed using alpha-Cry-specific monoclonal antibody. The results reported here point to a novel function of alpha-Cry besides the structural properties in the lens.

  2. Recombining plasma in the gamma-ray-emitting mixed-morphology supernova remnant 3C 391

    Energy Technology Data Exchange (ETDEWEB)

    Ergin, T.; Sezer, A. [TUBITAK Space Technologies Research Institute, ODTU Campus, 06531 Ankara (Turkey); Saha, L.; Majumdar, P.; Chatterjee, A. [Saha Institute of Nuclear Physics, Kolkata, West Bengal 700064 (India); Bayirli, A.; Ercan, E. N., E-mail: tulun.ergin@tubitak.gov.tr [Physics Department, Bogazici University, Bebek, 34342 Istanbul (Turkey)

    2014-07-20

    A group of middle-aged mixed-morphology (MM) supernova remnants (SNRs) interacting with molecular clouds (MCs) has been discovered to be strong GeV gamma-ray emitters by the Large Area Telescope (LAT) on board the Fermi Gamma-Ray Space Telescope (Fermi-LAT). The recent observations of the Suzaku X-ray satellite have revealed that some of these interacting gamma-ray-emitting SNRs, such as IC443, W49B, W44, and G359.1-0.5, have overionized plasmas. 3C 391 (G31.9+0.0) is another Galactic MM SNR interacting with MCs. It was observed in GeV gamma rays by Fermi-LAT as well as in the 0.3-10.0 keV X-ray band by Suzaku. In this work, 3C 391 was detected in GeV gamma rays with a significance of ∼18σ and we showed that the GeV emission is point-like in nature. The GeV gamma-ray spectrum was shown to be best explained by the decay of neutral pions assuming that the protons follow a broken power-law distribution. We revealed radiative recombination structures of silicon and sulfur from 3C 391 using Suzaku data. In this paper, we discuss the possible origin of this type of radiative plasma and hadronic gamma rays.

  3. Correcting the effects of the matrix using capture gamma-ray spectrometry: Application to measurement by Active Neutron Interrogation

    International Nuclear Information System (INIS)

    Baudry, G.

    2003-11-01

    In the field of the measurement of low masses of fissile material ( 235 U, 239 Pu, 241 Pu) in radioactive waste drums, the Active Neutron Interrogation is a non-destructive method achieving good results. It does however remain reliant upon uncertainties related to the matrix effects on interrogation and fission neutrons. The aim of this thesis is to develop a correction method able to take into account these matrix effects by quantifying the amount of absorbent materials (chlorine and hydrogen) in a 118- liter homogeneous matrix. The main idea is to use the gamma-ray spectrometry of gamma emitted by neutron captures to identify and quantify the composition of the matrix. An indicator from its chlorine content is then deduced in order to choose the calibration coefficient which best represents the real composition of the matrix. This document firstly presents the needs of control and characterization of radioactive objects, and the means used in the field of nuclear measurement. Emphases is put in particular on the Active Neutron Interrogation method. The matrices of interest are those made of light technological waste (density ≤ 0,4 g/cm 3 ) containing hydrogenated and chlorinated materials. The advantages of gamma-rays emitted by neutron captures for the determination of a chlorine content indicator of the matrices and the principles of the correction method are then explained. Measurements have been firstly realized with an existing Neutron Interrogation device (PROMETHEE 6). Such measurements have proven its inadequacy: no signal from the matrix hydrogen was detected, due to an intense signal from the polyethylene contained in some cell elements. Moreover, the matrix chlorine content appeared difficult to be measured. A new and specific device, named REGAIN and dedicated to active gamma-rays spectrometry, was defined with the Monte-Carlo N-Particle (MCNP) code. The experiments conducted with this new device made it possible to detect the hydrogen from the

  4. Scanning of Cargo Containers by Gamma-Ray and Fast Neutron Radiography

    International Nuclear Information System (INIS)

    Yousri, A.M.; Bashter, I.I.; Megahid, M.R.; Osman, A.M.; Kansouh, W.A.; Reda, A.M.

    2011-01-01

    This paper describes the combined systems which were installed and tested to detect contraband smuggled in cargo containers. These combined systems are based on radiographers work by gamma-rays emitted from point source 60 Co with 0.5 Ci activity and neutrons emitted from point isotopic sources of Pu-α-Be as well as 14 MeV neutrons emitted from sealed tube neutron generator. The transmitted gamma ray through the inspected object was measured by gamma detection system with NaI(Tl) detector while the transmitted fast neutron beam was measured by a neutron gamma detection system with stilbene organic scintillator. The later possess the capability of discrimination between between gamma and neutron pulses using a discrimination system based on pulse shape discrimination method. The measured intensities of primary incident and transmitted beams of gamma-rays and fast neutrons were used to construct 2D cross-sectional images of the inspected objects hidden directly within benign materials of the container and for object screened by high dense material to stop object detection by gamma or X-rays. The constructed images for the inspected objects show the good capability and effectiveness of the installed gamma and neutron radiographers to detect illicit materials hidden in air cargo containers and sea containers of med size. They have also indicated that the developed scanning systems possess the ease of mobility and low cost of scanning

  5. Absorption of gamma-emitting fission products and activation products by rice under flooded and unflooded conditions from two tropical soils

    International Nuclear Information System (INIS)

    D'Souza, T.J.; Mistry, K.B.

    1980-01-01

    The absorption of gamma-emitting fission products 106 Ru, 125 Sb, 137 Cs and 144 Ce and activation products 59 Fe, 58 Co, 54 Mn and 65 Zn by rice plants grown on two contrasting tropical soils, namely, a blak soil (pellustert) and a laterite (oxisol), and the effects of flooding were studied under controlled conditions. Results indicated greater uptake of 106 Ru and 125 Sb from the black soil than from the laterite. In contrast, the uptake of 144 Ce and 137 Cs was greater in the laterite than in the black soil. Flooding treatment enhanced the uptake of all these fission products by rice plants in the laterite soil whereas this effect was observed only for 125 Sb and 137 Cs in the black soil. The plant uptake of activation products from the two soil types showed maximum accumulation of 65 Zn followed by 54 Mn, 59 Fe and 58 Co in both soil types. Besides, uptake of these nuclides was greater from the laterite soil than from the black soil. Flooding treatment for rice while showing a reduction of 59 Fe uptake showed an increase in plant uptake of 58 Co, 54 Mn and 65 Zn in both soil types. (orig.)

  6. SEARCHING FOR OVERIONIZED PLASMA IN THE GAMMA-RAY-EMITTING SUPERNOVA REMNANT G349.7+0.2

    Energy Technology Data Exchange (ETDEWEB)

    Ergin, T.; Sezer, A. [TUBITAK Space Technologies Research Institute, ODTU Campus, 06531, Ankara (Turkey); Saha, L.; Majumdar, P. [Saha Institute of Nuclear Physics, Kolkata, West Bengal 700064 (India); Gök, F. [Akdeniz University, Faculty of Education, Department of Secondary Science and Mathematics Education, Antalya, 07058 (Turkey); Ercan, E. N., E-mail: tulun.ergin@tubitak.gov.tr [Bogazici University, Physics Department, Bebek, 34342, Istanbul (Turkey)

    2015-05-10

    G349.7+0.2 is a supernova remnant (SNR) expanding in a dense medium of molecular clouds and interacting with clumps of molecular material emitting gamma-rays. We analyzed the gamma-ray data of the Large Area Telescope on board the Fermi Gamma-Ray Space Telescope and detected G349.7+0.2 in the energy range of 0.2–300 GeV with a significance of ∼13σ, showing no extended morphology. Modeling of the gamma-ray spectrum revealed that the GeV gamma-ray emission dominantly originates from the decay of neutral pions, where the protons follow a broken power-law distribution with a spectral break at ∼12 GeV. To search for features of radiative recombination continua in the eastern and western regions of the remnant, we analyzed the Suzaku data of G349.7+0.2 and found no evidence for overionized plasma. In this paper, we discuss possible scenarios to explain the hadronic gamma-ray emission in G349.7+0.2 and the mixed morphology nature of this SNR.

  7. Neutron activation analysis for sulphur in coal samples and moisture content by gamma-ray transmission

    International Nuclear Information System (INIS)

    Selvi, S.

    1993-01-01

    A neutron activation analysis method is described for the determination of sulphur in coal samples by analysing the beta spectrum emitted from 32 P and 33 P following the reactions 32 S(n, p) 32 P and 33 S(n, p) 33 P using 252 Cf as a source of neutrons. The transmission of the combined gamma-rays emitted from three 137 Cs and three 241 Am sources is used to measure the water content of the coal samples. (author)

  8. Nuclear energy. Waste-packages activity measurement. Part. 1: high-resolution gamma spectrometry in integral mode with open geometry; ISO 14850-1: 2004. Energie nucleaire -- Mesurage de l'activite de colis de dechets. Partie 1: Spectrometrie gamma haute resolution en mode integral et geometrie ouverte

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    ISO 14850:2004 describes a procedure for measurements of gamma-emitting radionuclide activity in homogeneous objects such as unconditioned waste (including process waste, dismantling waste, etc.), waste conditioned in various matrices (bitumen, hydraulic binder, thermosetting resins, etc.), notably in the form of 100 L, 200 L, 400 L or 800 L drums, and test specimens or samples, (vitrified waste), and waste packaged in a container, notably technological waste. It also specifies the calibration of the gamma spectrometry chain. The gamma energies used generally range from 0,05 MeV to 3 MeV.

  9. Nuclear energy - Waste-packages activity measurement - Part.1: high-resolution gamma spectrometry in integral mode with open geometry; ISO 14850-1:2004. Energie nucleaire - Mesurage de l'activite de colis de dechets - Partie 1: spectrometrie gamma haute resolution en mode integral et geometrie ouverte

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    ISO 14850:2004 describes a procedure for measurements of gamma-emitting radionuclide activity in homogeneous objects such as unconditioned waste (including process waste, dismantling waste, etc.), waste conditioned in various matrices (bitumen, hydraulic binder, thermosetting resins, etc.), notably in the form of 100 L, 200 L, 400 L or 800 L drums, and test specimens or samples, (vitrified waste), and waste packaged in a container, notably technological waste. It also specifies the calibration of the gamma spectrometry chain. The gamma energies used generally range from 0,05 MeV to 3 MeV. (authors)

  10. Sensitivity to Antibiotics of Bacteria Exposed to Gamma Radiation Emitted from Hot Soils of the High Background Radiation Areas of Ramsar, Northern Iran

    Directory of Open Access Journals (Sweden)

    Seyed Mohammad Javad Mortazavi

    2017-04-01

    Full Text Available Background: Over the past several years our laboratories have investigated different aspects of the challenging issue of the alterations in bacterial susceptibility to antibiotics induced by physical stresses. Objective: To explore the bacterial susceptibility to antibiotics in samples of Salmonella enterica subsp. enterica serovar Typhimurium (S. typhimurium, Staphylococcus aureus, and Klebsiella pneumoniae after exposure to gamma radiation emitted from the soil samples taken from the high background radiation areas of Ramsar, northern Iran. Methods: Standard Kirby-Bauer test, which evaluates the size of the zone of inhibition as an indicator of the susceptibility of different bacteria to antibiotics, was used in this study. Results: The maximum alteration of the diameter of inhibition zone was found for K. pneumoniae when tested for ciprofloxacin. In this case, the mean diameter of no growth zone in non-irradiated control samples of K. pneumoniae was 20.3 (SD 0.6 mm; it was 14.7 (SD 0.6 mm in irradiated samples. On the other hand, the minimum changes in the diameter of inhibition zone were found for S. typhimurium and S. aureus when these bacteria were tested for nitrofurantoin and cephalexin, respectively. Conclusion: Gamma rays were capable of making significant alterations in bacterial susceptibility to antibiotics. It can be hypothesized that high levels of natural background radiation can induce adaptive phenomena that help microorganisms better cope with lethal effects of antibiotics.

  11. Sensitivity to Antibiotics of Bacteria Exposed to Gamma Radiation Emitted from Hot Soils of the High Background Radiation Areas of Ramsar, Northern Iran.

    Science.gov (United States)

    Mortazavi, Seyed Mohammad Javad; Zarei, Samira; Taheri, Mohammad; Tajbakhsh, Saeed; Mortazavi, Seyed Alireza; Ranjbar, Sahar; Momeni, Fatemeh; Masoomi, Samaneh; Ansari, Leila; Movahedi, Mohammad Mehdi; Taeb, Shahram; Zarei, Sina; Haghani, Masood

    2017-04-01

    Over the past several years our laboratories have investigated different aspects of the challenging issue of the alterations in bacterial susceptibility to antibiotics induced by physical stresses. To explore the bacterial susceptibility to antibiotics in samples of Salmonella enterica subsp. enterica serovar Typhimurium ( S. typhimurium ), Staphylococcus aureus , and Klebsiella pneumoniae after exposure to gamma radiation emitted from the soil samples taken from the high background radiation areas of Ramsar, northern Iran. Standard Kirby-Bauer test, which evaluates the size of the zone of inhibition as an indicator of the susceptibility of different bacteria to antibiotics, was used in this study. The maximum alteration of the diameter of inhibition zone was found for K. pneumoniae when tested for ciprofloxacin. In this case, the mean diameter of no growth zone in non-irradiated control samples of K. pneumoniae was 20.3 (SD 0.6) mm; it was 14.7 (SD 0.6) mm in irradiated samples. On the other hand, the minimum changes in the diameter of inhibition zone were found for S. typhimurium and S. aureus when these bacteria were tested for nitrofurantoin and cephalexin, respectively. Gamma rays were capable of making significant alterations in bacterial susceptibility to antibiotics. It can be hypothesized that high levels of natural background radiation can induce adaptive phenomena that help microorganisms better cope with lethal effects of antibiotics.

  12. Radiation Build-Up In Shielding Of Low Activity High Energia Gamma Source

    International Nuclear Information System (INIS)

    Helfi-Yuliati; Mukhlis-Akhadi

    2003-01-01

    Research to observe radiation build-up factor (b) in aluminium (Al), iron (Fe) and lead (Pb) for shielding of gamma radiation of high energy from 137 cs (E γ : 662 keV) source and 60 Co (E γ : 1332 keV) of low activity sources has been carried out. Al with Z =13 represent metal of low atomic number, Fe with Z =26 represent metal of medium atomic number, and Pb with Z = 82 represent metal of high atomic number. Low activity source in this research is source which if its dose rate decrease to 3 % of its initial dose rate became safe for the workers. Research was conducted by counting of radiation intensity behind shielding with its thickness vary from 1 to 5 times of half value thickness (HVT). NaI(TI) detector which connected to multi channel analyzer (MCA) was used for the counting. Calculation result show that all of b value are close to 1 (b ∼ 1) for all kinds of metals. No radiation build-up factor is required in estimating the shielding thickness from several kinds of metals for low activity of high energy gamma source. (author)

  13. Natural gamma-emitting radionuclides in egyptian cement

    International Nuclear Information System (INIS)

    El Arabi, A.M.; Abbady, A.; El Kamel, A.H.; Nosier, A.; Moustafa, A.

    2005-01-01

    Samples of cement manufactured in Egypt and the various raw materials, which compose the product, have been analyzed using gamma-spectroscopy, in order to determine the concentration of natural radionuclides and associated radiological hazard. The mean of specific activity due to all the three radionuclides (226 R a, 232 T h and 40 K ) were found to be 20±4 , 11± 2, 320 ± 18 (gypsum), 41 ±8, 27± 5, 410± 27 (clay), 58 ± 11, 18 3, 321± 20 (Iron ore) and 37.6 ± 6, 11.8 ± 3, 178.6 ± 15 Bq.kg-1 (Portland cement), respectively. 40 K concentration could not be detected in Slag; limestone; Sulphate resistant cement; Clinker and White cement, while the mean activity concentrations of 226 R a and 232 T h are 239 ± 16, 48.7 ± 7; 31.5 ±5, 10 ± 2; 47 ± 7, 20 ± 4; 23 ± 5, 10.4 ± 3 and 23 ± 5, 11 ±3 Bq.kg-1, respectively. The measured activity concentrations of these natural radionuclides were compared with data of some countries. The present values are in the same range and sometimes less than those in other countries

  14. Natural gamma-emitting radionuclides in egyptian cement

    International Nuclear Information System (INIS)

    El-Arabi, A.M.; Abbady, A.; El-Kamel, A.H.; Nosier, A.; Moustafa, A.

    2005-01-01

    Samples of cement manufactured in Egypt and the various raw materials, which compose the product, have been analyzed using gamma-spectroscopy, in order to determine the concentration of natural radionuclides and associated radiological hazard. The mean of specific activity due to all the three radionuclides (226 R a, 232 T h and 40 K ) were found to be 20 ± 4 , 11 ± 2, 320 ± 18 (gypsum), 41 ± 8, 27 ± 5, 410 ± 27 (clay), 58 ± 11, 18 3, 321 ± 20 (Iron ore) and 37.6 ± 6, 11.8 ± 3, 178.6 ± 15 Bq.kg-1 (Portland cement), respectively. 40 K concentration could not be detected in Slag; limestone; Sulphate resistant cement; Clinker and White cement, while the mean activity concentrations of 226 R a and 232 T h are 239 ± 16, 48.7 ± 7; 31.5 ± 5, 10 ± 2; 47 3 ± 7, 20 ± 4; 23 ± 5, 10.4 ± 3 and 23 ± 5, 11 ± 3 Bq.kg-1, respectively. The measured activity concentrations of these natural radionuclides were compared with data of some countries. The present values are in the same range and sometimes less than those in other countries

  15. SWEPP Gamma-Ray Spectrometer System software design description

    International Nuclear Information System (INIS)

    Femec, D.A.; Killian, E.W.

    1994-08-01

    To assist in the characterization of the radiological contents of contract-handled waste containers at the Stored Waste Examination Pilot Plant (SWEPP), the SWEPP Gamma-Ray Spectrometer (SGRS) System has been developed by the Radiation Measurements and Development Unit of the Idaho National Engineering Laboratory. The SGRS system software controls turntable and detector system activities. In addition to determining the concentrations of gamma-ray-emitting radionuclides, this software also calculates attenuation-corrected isotopic mass ratios of-specific interest. This document describes the software design for the data acquisition and analysis software associated with the SGRS system

  16. SWEPP Gamma-Ray Spectrometer System software design description

    Energy Technology Data Exchange (ETDEWEB)

    Femec, D.A.; Killian, E.W.

    1994-08-01

    To assist in the characterization of the radiological contents of contract-handled waste containers at the Stored Waste Examination Pilot Plant (SWEPP), the SWEPP Gamma-Ray Spectrometer (SGRS) System has been developed by the Radiation Measurements and Development Unit of the Idaho National Engineering Laboratory. The SGRS system software controls turntable and detector system activities. In addition to determining the concentrations of gamma-ray-emitting radionuclides, this software also calculates attenuation-corrected isotopic mass ratios of-specific interest. This document describes the software design for the data acquisition and analysis software associated with the SGRS system.

  17. NEW FERMI-LAT EVENT RECONSTRUCTION REVEALS MORE HIGH-ENERGY GAMMA RAYS FROM GAMMA-RAY BURSTS

    Energy Technology Data Exchange (ETDEWEB)

    Atwood, W. B. [Santa Cruz Institute for Particle Physics, Department of Physics and Department of Astronomy and Astrophysics, University of California at Santa Cruz, Santa Cruz, CA 95064 (United States); Baldini, L. [Universita di Pisa and Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, I-56127 Pisa (Italy); Bregeon, J.; Pesce-Rollins, M.; Sgro, C.; Tinivella, M. [Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, I-56127 Pisa (Italy); Bruel, P. [Laboratoire Leprince-Ringuet, Ecole polytechnique, CNRS/IN2P3, Palaiseau (France); Chekhtman, A. [Center for Earth Observing and Space Research, College of Science, George Mason University, Fairfax, VA 22030 (United States); Cohen-Tanugi, J. [Laboratoire Univers et Particules de Montpellier, Universite Montpellier 2, CNRS/IN2P3, F-34095 Montpellier (France); Drlica-Wagner, A.; Omodei, N.; Rochester, L. S.; Usher, T. L. [W. W. Hansen Experimental Physics Laboratory, Kavli Institute for Particle Astrophysics and Cosmology, Department of Physics and SLAC National Accelerator Laboratory, Stanford University, Stanford, CA 94305 (United States); Granot, J. [Department of Natural Sciences, The Open University of Israel, 1 University Road, P.O. Box 808, Ra' anana 43537 (Israel); Longo, F. [Istituto Nazionale di Fisica Nucleare, Sezione di Trieste, I-34127 Trieste (Italy); Razzaque, S. [Department of Physics, University of Johannesburg, Auckland Park 2006 (South Africa); Zimmer, S., E-mail: melissa.pesce.rollins@pi.infn.it, E-mail: nicola.omodei@stanford.edu, E-mail: granot@openu.ac.il [Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm (Sweden)

    2013-09-01

    Based on the experience gained during the four and a half years of the mission, the Fermi-LAT Collaboration has undertaken a comprehensive revision of the event-level analysis going under the name of Pass 8. Although it is not yet finalized, we can test the improvements in the new event reconstruction with the special case of the prompt phase of bright gamma-ray bursts (GRBs), where the signal-to-noise ratio is large enough that loose selection cuts are sufficient to identify gamma rays associated with the source. Using the new event reconstruction, we have re-analyzed 10 GRBs previously detected by the Large Area Telescope (LAT) for which an X-ray/optical follow-up was possible and found four new gamma rays with energies greater than 10 GeV in addition to the seven previously known. Among these four is a 27.4 GeV gamma ray from GRB 080916C, which has a redshift of 4.35, thus making it the gamma ray with the highest intrinsic energy ({approx}147 GeV) detected from a GRB. We present here the salient aspects of the new event reconstruction and discuss the scientific implications of these new high-energy gamma rays, such as constraining extragalactic background light models, Lorentz invariance violation tests, the prompt emission mechanism, and the bulk Lorentz factor of the emitting region.

  18. Gamma ray heating rates due to chromium isotopes in stellar core during late stages of high mass stars (>10M⊙

    Directory of Open Access Journals (Sweden)

    Nabi Jameel-Un

    2017-01-01

    Full Text Available Gamma ray heating rates are thought to play a crucial role during the pre-supernova stage of high mass stars. Gamma ray heating rates, due to β±-decay and electron (positron capture on chromium isotopes, are calculated using proton-neutron quasiparticle random phase approximation theory. The electron capture significantly affects the lepton fraction (Ye and accelerates the core contraction. The gamma rays emitted as a result of weak processes heat the core and tend to hinder the cooling and contraction due to electron capture and neutrino emission. The emitted gamma rays tend to produce enormous entropy and set the convection to play its role at this stage. The gamma heating rates, on 50-60Cr, are calculated for the density range 10 < ρ (g.cm-3 < 1011 and temperature range 107 < T (K < 3.0×1010.

  19. Direct electrical stimulation of human cortex evokes high gamma activity that predicts conscious somatosensory perception

    Science.gov (United States)

    Muller, Leah; Rolston, John D.; Fox, Neal P.; Knowlton, Robert; Rao, Vikram R.; Chang, Edward F.

    2018-04-01

    Objective. Direct electrical stimulation (DES) is a clinical gold standard for human brain mapping and readily evokes conscious percepts, yet the neurophysiological changes underlying these percepts are not well understood. Approach. To determine the neural correlates of DES, we stimulated the somatosensory cortex of ten human participants at frequency-amplitude combinations that both elicited and failed to elicit conscious percepts, meanwhile recording neural activity directly surrounding the stimulation site. We then compared the neural activity of perceived trials to that of non-perceived trials. Main results. We found that stimulation evokes distributed high gamma activity, which correlates with conscious perception better than stimulation parameters themselves. Significance. Our findings suggest that high gamma activity is a reliable biomarker for perception evoked by both natural and electrical stimuli.

  20. Mobility of gamma-emitting fission products in typical black and laterite soils

    International Nuclear Information System (INIS)

    D'Souza, T.J.; Mistry, K.B.

    1981-01-01

    Studies on the movement of the gamma-emitting fission products 106 Ru, 125 Sb, 137 Cs and 144 Ce, surface deposited on columns of the black and laterite soils revealed that the mobility of these nuclides in the two soils depended mainly on the ionic form of the nuclide, soil reaction and predominant clay mineral type in the soil. Results showed a rapid breakthrough of 106 Ru in the black soil and considerable migration to the lower layers in the laterite soil on leaching with rain water, or moderately high calcium or sodium irrigation waters. While near complete fixation of 144 Ce and 137 Cs in the top contaminated layer of both soils was observed, a slight movement of 125 Sb only in the black soil was noticed. Incorporation of organic matter had no effects on the movement of fission products in both soil types, whereas ethylenediaminetraacetic acid (EDTA) induced variable movement of the different radionuclides in the two soil types. (author)

  1. Estimation of neutron energy distributions from prompt gamma emissions

    Science.gov (United States)

    Panikkath, Priyada; Udupi, Ashwini; Sarkar, P. K.

    2017-11-01

    A technique of estimating the incident neutron energy distribution from emitted prompt gamma intensities from a system exposed to neutrons is presented. The emitted prompt gamma intensities or the measured photo peaks in a gamma detector are related to the incident neutron energy distribution through a convolution of the response of the system generating the prompt gammas to mono-energetic neutrons. Presently, the system studied is a cylinder of high density polyethylene (HDPE) placed inside another cylinder of borated HDPE (BHDPE) having an outer Pb-cover and exposed to neutrons. The emitted five prompt gamma peaks from hydrogen, boron, carbon and lead can be utilized to unfold the incident neutron energy distribution as an under-determined deconvolution problem. Such an under-determined set of equations are solved using the genetic algorithm based Monte Carlo de-convolution code GAMCD. Feasibility of the proposed technique is demonstrated theoretically using the Monte Carlo calculated response matrix and intensities of emitted prompt gammas from the Pb-covered BHDPE-HDPE system in the case of several incident neutron spectra spanning different energy ranges.

  2. Response-surface models for deterministic effects of localized irradiation of the skin by discrete {beta}/{gamma} -emitting sources

    Energy Technology Data Exchange (ETDEWEB)

    Scott, B.R.

    1995-12-01

    Individuals who work at nuclear reactor facilities can be at risk for deterministic effects in the skin from exposure to discrete {Beta}- and {gamma}-emitting ({Beta}{gamma}E) sources (e.g., {Beta}{gamma}E hot particles) on the skin or clothing. Deterministic effects are non-cancer effects that have a threshold and increase in severity as dose increases (e.g., ulcer in skin). Hot {Beta}{gamma}E particles are {sup 60}Co- or nuclear fuel-derived particles with diameters > 10 {mu}m and < 3 mm and contain at least 3.7 kBq (0.1 {mu}Ci) of radioactivity. For such {Beta}{gamma}E sources on the skin, it is the beta component of the dose that is most important. To develop exposure limitation systems that adequately control exposure of workers to discrete {Beta}{gamma}E sources, models are needed for systems that adequately control exposure of workers to discrete {Beta}{gamma}E sources, models are needed for evaluating the risk of deterministic effects of localized {Beta} irradiation of the skin. The purpose of this study was to develop dose-rate and irradiated-area dependent, response-surface models for evaluating risks of significant deterministic effects of localized irradiation of the skin by discrete {Beta}{gamma}E sources and to use modeling results to recommend approaches to limiting occupational exposure to such sources. The significance of the research results as follows: (1) response-surface models are now available for evaluating the risk of specific deterministic effects of localized irradiation of the skin; (2) modeling results have been used to recommend approaches to limiting occupational exposure of workers to {Beta} radiation from {Beta}{gamma}E sources on the skin or on clothing; and (3) the generic irradiated-volume, weighting-factor approach to limiting exposure can be applied to other organs including the eye, the ear, and organs of the respiratory or gastrointestinal tract and can be used for both deterministic and stochastic effects.

  3. Freshly induced short-lived gamma-ray activity as a measure of fission rates in lightly re-irradiated spent fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kroehnert, H., E-mail: hanna.kroehnert@psi.c [Paul Scherrer Institut (PSI), OPRA-E07, CH-5232 Villigen (Switzerland); Perret, G., E-mail: gregory.perret@psi.c [Paul Scherrer Institut (PSI), OPRA-E07, CH-5232 Villigen (Switzerland); Murphy, M.F., E-mail: mike.murphy@psi.c [Paul Scherrer Institut (PSI), OPRA-E07, CH-5232 Villigen (Switzerland); Chawla, R., E-mail: rakesh.chawla@epfl.c [Paul Scherrer Institut (PSI), OPRA-E07, CH-5232 Villigen (Switzerland); Ecole Polytechnique Federale de Lausanne (EPFL), CH-1015 Lausanne (Switzerland)

    2010-12-01

    A new measurement technique has been developed to determine fission rates in burnt fuel, following re-irradiation in a zero-power research reactor. The development has been made in the frame of the LIFE-PROTEUS program at the Paul Scherrer Institute, which aims at characterizing the interfaces between fresh and highly burnt fuel assemblies in modern LWRs. To discriminate against the high intrinsic gamma-ray activity of the burnt fuel, the proposed measurement technique uses high-energy gamma-rays, above 2000 keV, emitted by short-lived fission products freshly produced in the fuel. To demonstrate the feasibility of this technique, a fresh UO{sub 2} sample and a 36 GWd/t burnt UO{sub 2} sample were irradiated in the PROTEUS reactor and their gamma-ray activities were recorded directly after irradiation. For both fresh and the burnt fuel samples, relative fission rates were derived for different core positions, based on the short-lived {sup 142}La (2542 keV), {sup 89}Rb (2570 keV), {sup 138}Cs (2640 keV) and {sup 95}Y (3576 keV) gamma-ray lines. Uncertainties on the inter-position fission rate ratios were mainly due to the uncertainties on the net-area of the gamma-ray peaks and were about 1-3% for the fresh sample, and 3-6% for the burnt one. Thus, for the first time, it has been shown that the short-lived gamma-ray activity, induced in burnt fuel by irradiation in a zero-power reactor, can be used as a quantitative measure of the fission rate. For both fresh and burnt fuel, the measured results agreed, within the uncertainties, with Monte Carlo (MCNPX) predictions.

  4. Gamma-irradiation activates biochemical systems: induction of nitrate reductase activity in plant callus.

    OpenAIRE

    Pandey, K N; Sabharwal, P S

    1982-01-01

    Gamma-irradiation induced high levels of nitrate reductase activity (NADH:nitrate oxidoreductase, EC 1.6.6.1) in callus of Haworthia mirabilis Haworth. Subcultures of gamma-irradiated tissues showed autonomous growth on minimal medium. We were able to mimic the effects of gamma-irradiation by inducing nitrate reductase activity in unirradiated callus with exogenous auxin and kinetin. These results revealed that induction of nitrate reductase activity by gamma-irradiation is mediated through i...

  5. Absorption of gamma-emitting fission products and activation products by rice under flooded and unflooded conditions from two tropical soils

    Energy Technology Data Exchange (ETDEWEB)

    D' Souza, T J; Mistry, K B [Bhabha Atomic Research Centre, Bombay (India). Biology and Agriculture Div.

    1980-01-01

    The absorption of gamma-emitting fission products /sup 106/Ru, /sup 125/Sb, /sup 137/Cs and /sup 144/Ce and activation products /sup 59/Fe, /sup 58/Co, /sup 54/Mn and /sup 65/Zn by rice plants grown on two contrasting tropical soils, namely, a blak soil (pellustert) and a laterite (oxisol), and the effects of flooding were studied under controlled conditions. Results indicated greater uptake of /sup 106/Ru and /sup 125/Sb from the black soil than from the laterite. In contrast, the uptake of /sup 144/Ce and /sup 137/Cs was greater in the laterite than in the black soil. Flooding treatment enhanced the uptake of all these fission products by rice plants in the laterite soil whereas this effect was observed only for /sup 125/Sb and /sup 137/Cs in the black soil. The plant uptake of activation products from the two soil types showed maximum accumulation of /sup 65/Zn followed by /sup 54/Mn, /sup 59/Fe and /sup 58/Co in both soil types. Besides, uptake of these nuclides was greater from the laterite soil than from the black soil. Flooding treatment for rice while showing a reduction of /sup 59/Fe uptake showed an increase in plant uptake of /sup 58/Co, /sup 54/Mn and /sup 65/Zn in both soil types.

  6. Gene expression profiling in cells with enhanced gamma-secretase activity.

    Directory of Open Access Journals (Sweden)

    Alexandra I Magold

    2009-09-01

    Full Text Available Processing by gamma-secretase of many type-I membrane protein substrates triggers signaling cascades by releasing intracellular domains (ICDs that, following nuclear translocation, modulate the transcription of different genes regulating a diverse array of cellular and biological processes. Because the list of gamma-secretase substrates is growing quickly and this enzyme is a cancer and Alzheimer's disease therapeutic target, the mapping of gamma-secretase activity susceptible gene transcription is important for sharpening our view of specific affected genes, molecular functions and biological pathways.To identify genes and molecular functions transcriptionally affected by gamma-secretase activity, the cellular transcriptomes of Chinese hamster ovary (CHO cells with enhanced and inhibited gamma-secretase activity were analyzed and compared by cDNA microarray. The functional clustering by FatiGO of the 1,981 identified genes revealed over- and under-represented groups with multiple activities and functions. Single genes with the most pronounced transcriptional susceptibility to gamma-secretase activity were evaluated by real-time PCR. Among the 21 validated genes, the strikingly decreased transcription of PTPRG and AMN1 and increased transcription of UPP1 potentially support data on cell cycle disturbances relevant to cancer, stem cell and neurodegenerative diseases' research. The mapping of interactions of proteins encoded by the validated genes exclusively relied on evidence-based data and revealed broad effects on Wnt pathway members, including WNT3A and DVL3. Intriguingly, the transcription of TERA, a gene of unknown function, is affected by gamma-secretase activity and was significantly altered in the analyzed human Alzheimer's disease brain cortices.Investigating the effects of gamma-secretase activity on gene transcription has revealed several affected clusters of molecular functions and, more specifically, 21 genes that hold significant

  7. Volatiles emitted from flowers by gamma-radiated and nonradiated Jasminum polyanthum Franch. in situ

    International Nuclear Information System (INIS)

    Christensen, L.P.; Jakobsen, H.B.; Kristiansen, K.; Moller, J.

    1997-01-01

    Volatile compounds emitted from flowers of Jasminum polyanthum Pepita in situ were collected by dynamic headspace technique and analyzed by GC-FID and GC-MS. A total of 32 compounds were identified. The flower scent was dominated by benzyl acetate (57.8%), p-cresol (12.2%), (E)-isoeugenol (9.7%), eugenol (3.5%), 2-methoxy-p-cresol (3.1%), linalool (3.0%), phenethyl acetate (2.1%), and (Z)3-hexenyl butyrate (1.9%). The strong scent of Pepita reduces its production potentialities as a pot plant, thus the possibility to reduce or modify the emission of volatiles from Pepita by mutagenesis was investigated. The average total yields of volatiles in Pepita were approximately 2800 ng flower-1 h-1, and in one gamma-radiated clone a significantly lower yield of 1050 ng flower-1 h-1 was found. The volatile profiles of the gamma-radiated plants were made up of the same 32 compounds found in Pepita. Significant differences in the headspace composition between Pepita and gamma-radiated plants were found for some of the major volatiles

  8. Quantitative portable gamma-spectroscopy sample analysis for non-standard sample geometries

    International Nuclear Information System (INIS)

    Ebara, S.B.

    1998-01-01

    Utilizing a portable spectroscopy system, a quantitative method for analysis of samples containing a mixture of fission and activation products in nonstandard geometries was developed. This method was not developed to replace other methods such as Monte Carlo or Discrete Ordinates but rather to offer an alternative rapid solution. The method can be used with various sample and shielding configurations where analysis on a laboratory based gamma-spectroscopy system is impractical. The portable gamma-spectroscopy method involves calibration of the detector and modeling of the sample and shielding to identify and quantify the radionuclides present in the sample. The method utilizes the intrinsic efficiency of the detector and the unattenuated gamma fluence rate at the detector surface per unit activity from the sample to calculate the nuclide activity and Minimum Detectable Activity (MDA). For a complex geometry, a computer code written for shielding applications (MICROSHIELD) is utilized to determine the unattenuated gamma fluence rate per unit activity at the detector surface. Lastly, the method is only applicable to nuclides which emit gamma-rays and cannot be used for pure beta or alpha emitters. In addition, if sample self absorption and shielding is significant, the attenuation will result in high MDA's for nuclides which solely emit low energy gamma-rays. The following presents the analysis technique and presents verification results using actual experimental data, rather than comparisons to other approximations such as Monte Carlo techniques, to demonstrate the accuracy of the method given a known geometry and source term. (author)

  9. 16 alpha-[77Br]bromoestradiol-17 beta: a high specific-activity, gamma-emitting tracer with uptake in rat uterus and uterus and induced mammary tumors

    International Nuclear Information System (INIS)

    Katzenellenbogen, J.A.; Senderoff, S.G.; McElvany, K.D.; O'Brien, H.A. Jr.; Welch, M.J.

    1981-01-01

    16 alpha-[77Br]bromoestradiol-17 beta (Compound 1) has been synthesized by radiobromination of estrone enoldiacetate. Tissue uptake studies performed 1 h after administration of Compound 1 to immature or mature female rats showed uterus-to-blood ratios of 13, with nontarget issue-to-blood ratios ranging from 0.6 to 2. Co-administration of unlabelled estradiol caused a selective depression in the uterine uptake with no effect on nontarget tissue uptake. In adult animals bearing adenocarcinomas induced by DMBA (7,12-dimethylbenz(a)anthracene), tumor-to-blood ratios of 6.3 were obtained, this uptake also being depressed in animals treated with unlabeled estradiol. The studies demonstrate that Compound 1 has suitable binding properties and sufficiently high specific activity so that its uptake in estrogen target tissues in vivo is mediated primarily by the estrogen receptor. Furthermore, they suggest that this compound may be suitable for imaging human breast tumors that contain estrogen receptors

  10. A spectral study of gamma-ray emitting active galactic nuclei

    DEFF Research Database (Denmark)

    Pohl, M.; Hartman, R.C.; Jones, B.B.

    1997-01-01

    In this paper we present a statistical analysis of the gamma-ray spectra of flat-spectrum radio quasars (FSRQ) compared to those of BL Lacs. The average spectra and possible systematic deviations from power-law behaviour are investigated by summing up the intensity and the power-law fit statistic...

  11. Fission-product yields for thermal-neutron fission of 243Cm determined from measurements with a high-resolution low-energy germanium gamma-ray detector

    International Nuclear Information System (INIS)

    Merriman, L.D.

    1984-04-01

    Cumulative fission-product yields have been determined for 13 gamma rays emitted during the decay of 12 fission products created by thermal-neutron fission of 243 Cm. A high-resolution low-energy germanium detector was used to measure the pulse-height spectra of gamma rays emitted from a 77-nanogram sample of 243 Cm after the sample had been irradiated by thermal neutrons. Analysis of the data resulted in the identification and matching of gamma-ray energies and half-lives to individual radioisotopes. From these results, 12 cumulative fission product yields were deduced for radionuclides with half-lives between 4.2 min and 84.2 min. 7 references

  12. The study of specific activity and effect of gamma ray from natural radionuclide to the environment outside Sultan Abdul Aziz Plant Station, Kapar, Klang, Selangor

    International Nuclear Information System (INIS)

    Wan Amar Fikri Wan Ali

    2012-01-01

    Waste resulting from coal combustion process can result in increasing the specific activity of natural radionuclide such as 238 U, 232 Th , 226 Ra and 40 K. Following combustion, radionuclide focused on fly ash, some escape the filtration system in the chimney that causes the gamma ray exposure dose increases. The objective of this study was to calculate the specific activity of natural radionuclide and identifying the gamma ray exposure dose outside the Stesen Janakuasa Elektric Station of Sultan Abdul Aziz further examine the risk of gamma ray exposure dose and specific activity of natural radionuclide to the ecosystem because the station is located close to residential areas and local residents migratory bird stopover. The samples studied are soil, water and sediment that are outside the station. Samples taken with the correct procedures then treated and stored about a month before counting. Gamma ray exposure dose for the seven stations studied are between 0.330 μSv/ h - 1.20 μSv/ h. While the range of specific activities obtained for the 40 K, 238 U, 232 Th and 226 Ra were 201 Bq/ kg - 468 Bq/ kg, 0.480 Bq/ kg - 2.57 Bq/ kg, 12.9 Bq/ kg - 74.5 Bq/ kg and 6.64 Bq/ kg - 11.7 Bq/ kg. While the sediment samples were 216 Bq/ kg - 465 Bq/ kg, 18.1 Bq/ kg - 4.43 Bq/ kg, 24.8 Bq/ kg - 65.3 Bq/ kg, 8.53 Bq/ kg - 11.2 Bq/ kg. For water samples, the specific range of their specific activities are 10.5 Bq/ L - 12.1 Bq/ L, 1.40 Bq/ L - 1.63 Bq/ L, 1.57 Bq/ L - 1.65 Bq/ L and 0 Bq/ L - 1.14 Bq/ L. (author)

  13. High Energy Gamma-rays from FR I Jets

    CERN Document Server

    Sikora, M

    2003-01-01

    Thanks to Hubble and Chandra telescopes, some of the large scale jets in extragalactic radio sources are now being observed at optical and X-ray frequencies. For the FR I objects the synchrotron nature of this emission is surely established, although a lot of uncertainties--connected for example with the particle acceleration processes involved--remain. In this paper we study production of high energy gamma-rays in FR I kiloparsec-scale jets by inverse-Compton emission of the synchrotron-emitting electrons. We consider different origin of seed photons contributing to the inverse-Compton scattering, including nuclear jet radiation as well as ambient, stellar and circumstellar emission of the host galaxies. We discuss how future detections or non-detections of the evaluated gamma-ray fluxes can provide constraints on the unknown large scale jet parameters, i.e. the magnetic field intensity and the jet Doppler factor. For the nearby sources Centaurus A and M 87, we find measurable fluxes of TeV photons resulting...

  14. Mobile Phone Chips Reduce Increases in EEG Brain Activity Induced by Mobile Phone-Emitted Electromagnetic Fields

    Science.gov (United States)

    Henz, Diana; Schöllhorn, Wolfgang I.; Poeggeler, Burkhard

    2018-01-01

    Recent neurophysiological studies indicate that exposure to electromagnetic fields (EMFs) generated by mobile phone radiation can exert effects on brain activity. One technical solution to reduce effects of EMFs in mobile phone use is provided in mobile phone chips that are applied to mobile phones or attached to their surfaces. To date, there are no systematical studies on the effects of mobile phone chip application on brain activity and the underlying neural mechanisms. The present study investigated whether mobile phone chips that are applied to mobile phones reduce effects of EMFs emitted by mobile phone radiation on electroencephalographic (EEG) brain activity in a laboratory study. Thirty participants volunteered in the present study. Experimental conditions (mobile phone chip, placebo chip, no chip) were set up in a randomized within-subjects design. Spontaneous EEG was recorded before and after mobile phone exposure for two 2-min sequences at resting conditions. During mobile phone exposure, spontaneous EEG was recorded for 30 min during resting conditions, and 5 min during performance of an attention test (d2-R). Results showed increased activity in the theta, alpha, beta and gamma bands during EMF exposure in the placebo and no chip conditions. Application of the mobile phone chip reduced effects of EMFs on EEG brain activity and attentional performance significantly. Attentional performance level was maintained regarding number of edited characters. Further, a dipole analysis revealed different underlying activation patterns in the chip condition compared to the placebo chip and no chip conditions. Finally, a correlational analysis for the EEG frequency bands and electromagnetic high-frequency (HF) emission showed significant correlations in the placebo chip and no chip condition for the theta, alpha, beta, and gamma bands. In the chip condition, a significant correlation of HF with the theta and alpha bands, but not with the beta and gamma bands was

  15. Mobile Phone Chips Reduce Increases in EEG Brain Activity Induced by Mobile Phone-Emitted Electromagnetic Fields.

    Science.gov (United States)

    Henz, Diana; Schöllhorn, Wolfgang I; Poeggeler, Burkhard

    2018-01-01

    Recent neurophysiological studies indicate that exposure to electromagnetic fields (EMFs) generated by mobile phone radiation can exert effects on brain activity. One technical solution to reduce effects of EMFs in mobile phone use is provided in mobile phone chips that are applied to mobile phones or attached to their surfaces. To date, there are no systematical studies on the effects of mobile phone chip application on brain activity and the underlying neural mechanisms. The present study investigated whether mobile phone chips that are applied to mobile phones reduce effects of EMFs emitted by mobile phone radiation on electroencephalographic (EEG) brain activity in a laboratory study. Thirty participants volunteered in the present study. Experimental conditions (mobile phone chip, placebo chip, no chip) were set up in a randomized within-subjects design. Spontaneous EEG was recorded before and after mobile phone exposure for two 2-min sequences at resting conditions. During mobile phone exposure, spontaneous EEG was recorded for 30 min during resting conditions, and 5 min during performance of an attention test (d2-R). Results showed increased activity in the theta, alpha, beta and gamma bands during EMF exposure in the placebo and no chip conditions. Application of the mobile phone chip reduced effects of EMFs on EEG brain activity and attentional performance significantly. Attentional performance level was maintained regarding number of edited characters. Further, a dipole analysis revealed different underlying activation patterns in the chip condition compared to the placebo chip and no chip conditions. Finally, a correlational analysis for the EEG frequency bands and electromagnetic high-frequency (HF) emission showed significant correlations in the placebo chip and no chip condition for the theta, alpha, beta, and gamma bands. In the chip condition, a significant correlation of HF with the theta and alpha bands, but not with the beta and gamma bands was

  16. Monitoring gamma radioactivity over large land areas using portable equipment

    International Nuclear Information System (INIS)

    Mac Mahon, T.D.; Gray, P.W.; Eer, A.M. D'; Naboulsi, A.H.; Koutsoyannopoulos, C.

    1990-01-01

    The principal objective of this research has been to provide information on cost-effective techniques to detect localized areas of gamma-emitting radionuclides. This objective has been achieved by determining the time required to scan unit area as a function of depth of the gamma source below the site surface, the activity of the gamma source, the energy of the emitted gamma-ray, and the gamma transport properties of the site material. A comparison between survey and sampling techniques is made, and the advantages of using survey techniques to detect localized gamma-ray sources are discussed. A survey technique based on an adaptive moving array detector system is described. A field experiment has been carried out to verify the results of calculations of the sensitivity of the techniques described

  17. Formation properties from high resolution neutron activation gamma-ray spectra

    International Nuclear Information System (INIS)

    Mellor, D.W.; Underwood, M.C.

    1985-01-01

    A neutron activation logging tool has been developed comprising a Five Curie /sup 241/ Am-Be neutron source and a large n-type hyper-pure germanium gamma-ray detector. The tool maintains a constant temperature cryogenic environment for periods in excess of twenty hours. No liquid nitrogen or other consumable material is used in the operating or recharging stages. A large calibration tank in simulated well-bore geometry has been constructed with sand bodies saturated with oil and low salinity water (14,000 ppm NaCl). In the water zone prompt neutron capture gamma-rays from silicon, hydrogen and chlorine were prominent; gamma-rays from inelastic scattering on oxygen and silicon were detected. No gamma-rays arising from inelastic scattering on carbon were detected. These data have been interpreted to yield the porosity, fluid saturations, salinity and matrix composition. In the oil zone, gamma-rays arising from inelastic scattering on oxygen, silicon and carbon were detected. The intensity of the carbon line was very poor, and inadequate for quantitative purposes

  18. Prompt Gamma Radiation from Fragments in the Thermal Fission of 235U

    International Nuclear Information System (INIS)

    Albinsson, H.; Lindow, L.

    1970-06-01

    Measurements were made on the gamma radiation emitted from fission fragments in slow neutron induced fission of 235 U. The fragments were detected with solid state detectors of the surface barrier type and the gamma radiation with a Nal(Tl) scintillator. Mass selection was used so that the gamma radiation could be measured as a function of fragment mass. Time discrimination between the fission gammas and the prompt neutrons released in the fission process was employed to reduce the background. The gamma radiation emitted during different time intervals after the fission event was studied with the help of a collimator, the position of which was changed along the path of the fission fragments. In this way a decay curve was obtained from which the life-time of one of the gamma-emitting states could be estimated. The relative yield of the gamma-rays was determined as a function of mass for different gamma-ray energy portions and two specific time intervals after the fission events. Comparisons were made with data obtained from 252 Cf-fission. Attention is drawn to some features which seem to be the same in 235 U and 252 Cf-fission

  19. Numerical simulations on efficiency and measurement of capabilities of BGO detectors for high energy gamma ray

    CERN Document Server

    Wen Wan Xin

    2002-01-01

    The energy resolution and time resolution of two phi 75 x 100 BGO detectors for high energy gamma ray newly made were measured with sup 1 sup 3 sup 7 Cs and sup 6 sup 0 Co resources. The two characteristic gamma rays of high energy emitted from the thermal neutron capture of germanium in BGO crystal were used for the energy calibration of gamma spectra. The intrinsic photopeak efficiency, single escape probability and double escape probabilities of BGO detectors in photon energy range of 4-30 MeV are numerically calculated with GEANT code. The real count response and count ratio of the uniformly distributed incident photons in energy range of 0-30 MeV are also calculated. The distortion of gamma spectra caused by the photon energy loss extension to lower energy in detection medium is discussed

  20. Radiosensitivity of Prostate Cancer Cell Lines for Irradiation from Beta Particle-emitting Radionuclide ¹⁷⁷Lu Compared to Alpha Particles and Gamma Rays.

    Science.gov (United States)

    Elgqvist, Jörgen; Timmermand, Oskar Vilhelmsson; Larsson, Erik; Strand, Sven-Erik

    2016-01-01

    The purpose of the present study was to investigate the radiosensitivity of the prostate cancer cell lines LNCaP, DU145, and PC3 when irradiated with beta particles emitted from (177)Lu, and to compare the effect with irradiation using alpha particles or gamma rays. Cells were irradiated with beta particles emitted from (177)Lu, alpha particles from (241)Am, or gamma rays from (137)Cs. A non-specific polyclonal antibody was labeled with (177)Lu and used to irradiate cells in suspension with beta particles. A previously described in-house developed alpha-particle irradiator based on a (241)Am source was used to irradiate cells with alpha particles. External gamma-ray irradiation was achieved using a standard (137)Cs irradiator. Cells were irradiated to absorbed doses equal to 0, 0.5, 1, 2, 4, 6, 8, or 10 Gy. The absorbed doses were calculated as mean absorbed doses. For evaluation of cell survival, the tetrazolium-based WST-1 assay was used. After irradiation, WST-1 was added to the cell solutions, incubated, and then measured for level of absorbance at 450 nm, indicating the live and viable cells. LNCaP, DU145, and PC3 cell lines all had similar patterns of survival for the different radiation types. No significant difference in surviving fractions were observed between cells treated with beta-particle and gamma-ray irradiation, represented for example by the surviving fraction values (mean±SD) at 2, 6, and 10 Gy (SF2, SF6, and SF10) for DU145 after beta-particle irradiation: 0.700±0.090, 0.186±0.050 and 0.056±0.010, respectively. A strong radiosensitivity to alpha particles was observed, with SF2 values of 0.048±0.008, 0.018±0.006 and 0.015±0.005 for LNCaP, DU145, and PC3, respectively. The surviving fractions after irradiation using beta particles or gamma rays did not differ significantly at the absorbed dose levels and dose rates used. Irradiation using alpha particles led to a high level of cell killing. The results show that the beta-particle emitter

  1. Evaluation of a high-resolution, breast-specific, small-field-of-view gamma camera for the detection of breast cancer

    International Nuclear Information System (INIS)

    Brem, R.F.; Kieper, D.A.; Rapelyea, J.A.; Majewski, S.

    2003-01-01

    Purpose: The purpose of our study is to review the state of the art in nuclear medicine imaging of the breast (scintimammography) and to evaluate a novel, high-resolution, breast-specific gamma camera (HRBGC) for the detection of suspicious breast lesions. Materials and Methods: Fifty patients with 58 breast lesions in whom a scintimammogram was clinically indicated were prospectively evaluated with a general-purpose gamma camera and a HRBGC prototype. Nuclear studies were prospectively classified as negative (normal/benign) or positive (suspicious/malignant) by two radiologists, blinded to mammographic and histologic results with both the conventional and high-resolution. All lesions were confirmed by pathology. Results: Included in this study were 30 benign and 28 malignant lesions. The sensitivity for detection of breast cancer was 64.3% (18/28) with the conventional camera and 78.6% (22/28) with the HRBGC. Specificity of both systems was 93.3% (28/30). In the 18 nonpalpable cancers, sensitivity was 55.5% (10/18) and 72.2% (13/18) with the general-purpose camera and HRBGC, respectively. In cancers ≤ 1cm, 7 of 15 were detected with the general-purpose camera and 10 of 15 with the HRBGC. Four of the cancers (median size, 8.5 mm) detected with the HRBGC were missed by the conventional camera Conclusion: Evaluation of indeterminate breasts lesions with a high resolution, breast-specific gamma camera results in improved sensitivity for the detection of cancer with greater improvement demonstrated in nonpalpable and ≤1 cm cancers

  2. Reduction in Cortical Gamma Synchrony during Depolarized State of Slow Wave Activity in Mice

    Directory of Open Access Journals (Sweden)

    EUNJIN eHWANG

    2013-12-01

    Full Text Available EEG gamma band oscillations have been proposed to account for the neural synchronization crucial for perceptual integration. While increased gamma power and synchronization is generally observed during cognitive tasks performed during wake, several studies have additionally reported increased gamma power during sleep or anesthesia, raising questions about the characteristics of gamma oscillation during impaired consciousness and its role in conscious processing. Phase-amplitude modulation has been observed between slow wave activity (SWA, 0.5–4 Hz and gamma oscillations during ketamine/xylazine anesthesia or sleep, showing increased gamma activity corresponding to the depolarized (ON state of SWA. Here we divided gamma activity into its ON and OFF (hyperpolarized state components based on the phase of SWA induced by ketamine/xylazine anesthesia and compared their power and synchrony with wake state levels in mice. We further investigated the state-dependent changes in both gamma power and synchrony across primary motor and primary somatosensory cortical regions and their interconnected thalamic regions throughout anesthesia and recovery. As observed previously, gamma power was as high as during wake specifically during the ON state of SWA. However, the synchrony of this gamma activity between somatosensory-motor cortical regions was significantly reduced compared to the baseline wake state. In addition, the somatosensory-motor cortical synchrony of gamma oscillations was reduced and restored in an anesthetic state-dependent manner, reflecting the changing depth of anesthesia. Our results provide evidence that during anesthesia changes in long-range information integration between cortical regions might be more critical for changes in consciousness than changes in local gamma oscillatory power.

  3. Plutonium characterisation with prompt high energy gamma-rays from (n,gamma) reactions for nuclear warhead dismantlement verification

    Energy Technology Data Exchange (ETDEWEB)

    Postelt, Frederik; Gerald, Kirchner [Carl Friedrich von Weizsaecker-Centre for Science and Peace Research, Hamburg (Germany)

    2015-07-01

    Measurements of neutron induced gammas allow the characterisation of fissile material (i.e. plutonium and uranium), despite self- and additional shielding. Most prompt gamma-rays from radiative neutron capture reactions in fissile material have energies between 3 and 6.5 MeV. Such high energy photons have a high penetrability and therefore minimise shielding and self-absorption effects. They are also isotope specific and therefore well suited to determine the isotopic composition of fissile material. As they are non-destructive, their application in dismantlement verification is desirable. Disadvantages are low detector efficiencies at high gamma energies, as well as a high background of gammas which result from induced fission reactions in the fissile material, as well as delayed gammas from both, (n,f) and(n,gamma) reactions. In this talk, simulations of (n,gamma) measurements and their implications are presented. Their potential for characterising fissile material is assessed and open questions are addressed.

  4. Gamma-ray-spectroscopy following high-flux 14-MeV neutron activation

    International Nuclear Information System (INIS)

    Williams, R.E.

    1981-01-01

    The Rotating Target Neutron Source (RTNS-I), a high-intensity source of 14-MeV neutrons at the Lawrence Livermore National Laboratory (LLNL), has been used for applications in activation analysis, inertial-confinement-fusion diagnostic development, and fission decay-heat studies. The fast-neutron flux from the RTNS-I is at least 50 times the maximum fluxes available from typical neutron generators, making these applications possible. Facilities and procedures necessary for gamma-ray spectroscopy of samples irradiated at the RTNS-I were developed

  5. Gamma-ray-spectroscopy following high-flux 14-MeV neutron activation

    Energy Technology Data Exchange (ETDEWEB)

    Williams, R.E.

    1981-10-12

    The Rotating Target Neutron Source (RTNS-I), a high-intensity source of 14-MeV neutrons at the Lawrence Livermore National Laboratory (LLNL), has been used for applications in activation analysis, inertial-confinement-fusion diagnostic development, and fission decay-heat studies. The fast-neutron flux from the RTNS-I is at least 50 times the maximum fluxes available from typical neutron generators, making these applications possible. Facilities and procedures necessary for gamma-ray spectroscopy of samples irradiated at the RTNS-I were developed.

  6. Low and high gamma oscillations in rat ventral striatum have distinct relationships to behavior, reward, and spiking activity on a learned spatial decision task

    Directory of Open Access Journals (Sweden)

    Matthijs A A Van Der Meer

    2009-06-01

    Full Text Available Local field potential (LFP oscillations in the brain reflect organization thought to be important for perception, attention, movement, and memory. In the basal ganglia, including dorsal striatum, dysfunctional LFP states are associated with Parkinson’s disease, while in healthy subjects, dorsal striatal LFPs have been linked to decision-making processes. However, LFPs in ventral striatum have been less studied. We report that in rats running a spatial decision task, prominent gamma-50 (45-55 Hz and gamma-80 (70-85 Hz oscillations in ventral striatum had distinct relationships to behavior, task events, and spiking activity. Gamma-50 power increased sharply following reward delivery and before movement initiation, while in contrast, gamma-80 power ramped up gradually to reward locations. Gamma-50 power was low and contained little structure during early learning, but rapidly developed a stable pattern, while gamma-80 power was initially high before returning to a stable level within a similar timeframe. Putative fast-spiking interneurons (FSIs showed phase, firing rate, and coherence relationships with gamma-50 and gamma-80, indicating that the observed LFP patterns are locally relevant. Furthermore, in a number of FSIs such relationships were specific to gamma-50 or gamma-80, suggesting that partially distinct FSI populations mediate the effects of gamma-50 and gamma-80.

  7. Calorimetric measurement of strong γ emitting sources

    International Nuclear Information System (INIS)

    Brangier, B.; Herczeg, C.; Henry, R.

    1968-01-01

    This publication gives the principle and a description of an adiabatic calorimeter for measuring the real activity of strong gamma-emitting sources by absorbing the emitted energy in a mass of copper. Because of the difficulty of evaluating the amount self- absorption, we have built a calorimeter for measuring the self- absorption, and a description of it is given.The results of these three measurements are fairly satisfactory. The calibration and the actual measurements obtained are given with a few corrections made necessary by the design of the apparatus. The correlation of the various results is discussed. (author) [fr

  8. Prompt Gamma Radiation from Fragments in the Thermal Fission of {sup 235}U

    Energy Technology Data Exchange (ETDEWEB)

    Albinsson, H [Chalmers Univ. of Technology, Goteborg (Sweden); Lindow, L [AB Atomenergi, Nykoeping (Sweden)

    1970-06-15

    Measurements were made on the gamma radiation emitted from fission fragments in slow neutron induced fission of {sup 235}U. The fragments were detected with solid state detectors of the surface barrier type and the gamma radiation with a Nal(Tl) scintillator. Mass selection was used so that the gamma radiation could be measured as a function of fragment mass. Time discrimination between the fission gammas and the prompt neutrons released in the fission process was employed to reduce the background. The gamma radiation emitted during different time intervals after the fission event was studied with the help of a collimator, the position of which was changed along the path of the fission fragments. In this way a decay curve was obtained from which the life-time of one of the gamma-emitting states could be estimated. The relative yield of the gamma-rays was determined as a function of mass for different gamma-ray energy portions and two specific time intervals after the fission events. Comparisons were made with data obtained from {sup 252} Cf-fission. Attention is drawn to some features which seem to be the same in {sup 235}U and {sup 252} Cf-fission.

  9. Simulation of Neutron-Induced Prompt Gamma-ray Spectra Emitted from Fake Tungsten Gold Bar

    Energy Technology Data Exchange (ETDEWEB)

    Lee, K. M.; Sum, G. M. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Fake gold bars on the market cannot be identified easily without testing because they have the same appearance as a pure gold bar. A non-destructive monitoring method is needed to avoid the trading of fake gold bars on the market. The ultimate goal of this study is to find a fake gold bar detection method using a PGAA (Prompt Gamma Activation Analysis). Using existing data, the number of neutron capture for gold and tungsten in fake tungsten gold bar was calculated and a Monte Carlo simulation for the prompt neutron-induced gamma-ray spectra was conducted. A simulation for neutron-induced prompt gamma-rays spectra when a neutron beam is irradiated onto pure and fake gold bars was successfully conducted. Through a comparison between the prompt gamma-ray spectra of the pure gold bar and those of the fake gold bar, it was concluded that the observation of prompt high-energy gamma-rays from tungsten or a reduction of prompt gamma-rays from gold can be evidence of a fake gold bar. The possibility for detecting a fake gold bar using a PGAA facility was verified.

  10. Simulation of Neutron-Induced Prompt Gamma-ray Spectra Emitted from Fake Tungsten Gold Bar

    International Nuclear Information System (INIS)

    Lee, K. M.; Sum, G. M.

    2016-01-01

    Fake gold bars on the market cannot be identified easily without testing because they have the same appearance as a pure gold bar. A non-destructive monitoring method is needed to avoid the trading of fake gold bars on the market. The ultimate goal of this study is to find a fake gold bar detection method using a PGAA (Prompt Gamma Activation Analysis). Using existing data, the number of neutron capture for gold and tungsten in fake tungsten gold bar was calculated and a Monte Carlo simulation for the prompt neutron-induced gamma-ray spectra was conducted. A simulation for neutron-induced prompt gamma-rays spectra when a neutron beam is irradiated onto pure and fake gold bars was successfully conducted. Through a comparison between the prompt gamma-ray spectra of the pure gold bar and those of the fake gold bar, it was concluded that the observation of prompt high-energy gamma-rays from tungsten or a reduction of prompt gamma-rays from gold can be evidence of a fake gold bar. The possibility for detecting a fake gold bar using a PGAA facility was verified

  11. Gamma power is phase-locked to posterior alpha activity.

    Directory of Open Access Journals (Sweden)

    Daria Osipova

    Full Text Available Neuronal oscillations in various frequency bands have been reported in numerous studies in both humans and animals. While it is obvious that these oscillations play an important role in cognitive processing, it remains unclear how oscillations in various frequency bands interact. In this study we have investigated phase to power locking in MEG activity of healthy human subjects at rest with their eyes closed. To examine cross-frequency coupling, we have computed coherence between the time course of the power in a given frequency band and the signal itself within every channel. The time-course of the power was calculated using a sliding tapered time window followed by a Fourier transform. Our findings show that high-frequency gamma power (30-70 Hz is phase-locked to alpha oscillations (8-13 Hz in the ongoing MEG signals. The topography of the coupling was similar to the topography of the alpha power and was strongest over occipital areas. Interestingly, gamma activity per se was not evident in the power spectra and only became detectable when studied in relation to the alpha phase. Intracranial data from an epileptic subject confirmed these findings albeit there was slowing in both the alpha and gamma band. A tentative explanation for this phenomenon is that the visual system is inhibited during most of the alpha cycle whereas a burst of gamma activity at a specific alpha phase (e.g. at troughs reflects a window of excitability.

  12. Occult Breast Cancer: Scintimammography with High-Resolution Breast-specific Gamma Camera in Women at High Risk for Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Rachel F. Brem; Jocelyn A. Rapelyea; , Gilat Zisman; Kevin Mohtashemi; Joyce Raub; Christine B. Teal; Stan Majewski; Benjamin L. Welch

    2005-08-01

    To prospectively evaluate a high-resolution breast-specific gamma camera for depicting occult breast cancer in women at high risk for breast cancer but with normal mammographic and physical examination findings. MATERIALS AND METHODS: Institutional Review Board approval and informed consent were obtained. The study was HIPAA compliant. Ninety-four high-risk women (age range, 36-78 years; mean, 55 years) with normal mammographic (Breast Imaging Reporting and Data System [BI-RADS] 1 or 2) and physical examination findings were evaluated with scintimammography. After injection with 25-30 mCi (925-1110 MBq) of technetium 99m sestamibi, patients were imaged with a high-resolution small-field-of-view breast-specific gamma camera in craniocaudal and mediolateral oblique projections. Scintimammograms were prospectively classified according to focal radiotracer uptake as normal (score of 1), with no focal or diffuse uptake; benign (score of 2), with minimal patchy uptake; probably benign (score of 3), with scattered patchy uptake; probably abnormal (score of 4), with mild focal radiotracer uptake; and abnormal (score of 5), with marked focal radiotracer uptake. Mammographic breast density was categorized according to BI-RADS criteria. Patients with normal scintimammograms (scores of 1, 2, or 3) were followed up for 1 year with an annual mammogram, physical examination, and repeat scintimammography. Patients with abnormal scintimammograms (scores of 4 or 5) underwent ultrasonography (US), and those with focal hypoechoic lesions underwent biopsy. If no lesion was found during US, patients were followed up with scintimammography. Specific pathologic findings were compared with scintimammographic findings. RESULTS: Of 94 women, 78 (83%) had normal scintimammograms (score of 1, 2, or 3) at initial examination and 16 (17%) had abnormal scintimammograms (score of 4 or 5). Fourteen (88%) of the 16 patients had either benign findings at biopsy or no focal abnormality at US; in two

  13. Occult Breast Cancer: Scintimammography with High-Resolution Breast-specific Gamma Camera in Women at High Risk for Breast Cancer

    International Nuclear Information System (INIS)

    Rachel F. Brem; Jocelyn A. Rapelyea; , Gilat Zisman; Kevin Mohtashemi; Joyce Raub; Christine B. Teal; Stan Majewski; Benjamin L. Welch

    2005-01-01

    To prospectively evaluate a high-resolution breast-specific gamma camera for depicting occult breast cancer in women at high risk for breast cancer but with normal mammographic and physical examination findings. MATERIALS AND METHODS: Institutional Review Board approval and informed consent were obtained. The study was HIPAA compliant. Ninety-four high-risk women (age range, 36-78 years; mean, 55 years) with normal mammographic (Breast Imaging Reporting and Data System [BI-RADS] 1 or 2) and physical examination findings were evaluated with scintimammography. After injection with 25-30 mCi (925-1110 MBq) of technetium 99m sestamibi, patients were imaged with a high-resolution small-field-of-view breast-specific gamma camera in craniocaudal and mediolateral oblique projections. Scintimammograms were prospectively classified according to focal radiotracer uptake as normal (score of 1), with no focal or diffuse uptake; benign (score of 2), with minimal patchy uptake; probably benign (score of 3), with scattered patchy uptake; probably abnormal (score of 4), with mild focal radiotracer uptake; and abnormal (score of 5), with marked focal radiotracer uptake. Mammographic breast density was categorized according to BI-RADS criteria. Patients with normal scintimammograms (scores of 1, 2, or 3) were followed up for 1 year with an annual mammogram, physical examination, and repeat scintimammography. Patients with abnormal scintimammograms (scores of 4 or 5) underwent ultrasonography (US), and those with focal hypoechoic lesions underwent biopsy. If no lesion was found during US, patients were followed up with scintimammography. Specific pathologic findings were compared with scintimammographic findings. RESULTS: Of 94 women, 78 (83%) had normal scintimammograms (score of 1, 2, or 3) at initial examination and 16 (17%) had abnormal scintimammograms (score of 4 or 5). Fourteen (88%) of the 16 patients had either benign findings at biopsy or no focal abnormality at US; in two

  14. The opacity of the universe for high and very high energy {gamma}-rays

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Manuel

    2013-08-15

    The flux of high energy (HE, energy 100 MeVhigh energy (VHE, E>or similar 100 GeV) {gamma}-rays originating from cosmological sources is attenuated due to pair production in interactions with photons at ultraviolet to infrared wavelengths of the extragalactic background light (EBL). The main components contributing to the EBL photon density are the starlight integrated over cosmic time and the starlight reprocessed by dust in galaxies. Consequently, the EBL is an integral measure of the cosmic star formation history. Depending on the source distance, the Universe should be opaque to {gamma}-rays above a certain energy. Nevertheless, the number of detected {gamma}-ray sources has increased continuously in recent years. VHE emitting objects beyond redshifts of z>0.5 have been detected with imaging air Cherenkov telescopes (IACTs), while HE {gamma}-rays from active galactic nuclei (AGN) above redshifts z>or similar 3 have been observed with the Large Area Telescope (LAT) on board the Fermi satellite. In this work, a large sample of VHE {gamma}-ray spectra will be combined with data of the Fermi-LAT to derive upper limits on the EBL photon density at z = 0. Generic EBL realizations are used to correct AGN spectra for absorption, which are subsequently tested against model assumptions. The evolution of the EBL with redshift is accounted for, and a possible formation of electromagnetic cascades is considered. As a result, the EBL density is constrained over almost three orders of magnitude in wavelength, between 0.4 {mu}m and 100 {mu}m. At optical wavelengths, an EBL intensity above 24 nW m{sup -2}sr{sup -1} is ruled out, and between 8 {mu}m and 31 {mu}m it is limited to be below 5 nW m{sup -2}sr{sup -1}. In the infrared, the constraints are within a factor {proportional_to} 2 of lower limits derived from galaxy number counts. Additionally,the behavior of VHE spectra in the transition from the optical depth regimes {tau

  15. Direct measurement of γ-emitting radionuclides in waste drum

    International Nuclear Information System (INIS)

    Ma Ruwei; Mao Yong; Zhang Xiuzhen; Xia Xiaobin; Guo Caiping; Han Yueqin

    1993-01-01

    The low-level rad waste produced from nuclear power plant, nuclear facilities, and in the process of their decommissioning is stored in waste depository. For the safety of transport and storage of these wastes, some test must be done. One of them is to analyse the kinds and activities of radionuclides in each waste drum. Segmented scanning gamma spectrum analysis can be used for direct measurement of gamma-emitting radionuclides in drum. Gamma emitters such as Co-60, Cs-137, Ra-226 can be measured directly from outside of drum. A method and system for direct measuring gamma emitters in waste drum are described, and measuring apparatus and measurement results as well

  16. VLBI OBSERVATIONS OF THE JET IN M 87 DURING THE VERY HIGH ENERGY {gamma}-RAY FLARE IN 2010 APRIL

    Energy Technology Data Exchange (ETDEWEB)

    Hada, Kazuhiro; Giroletti, Marcello; Giovannini, Gabriele [INAF Istituto di Radioastronomia, via Gobetti 101, I-40129 Bologna (Italy); Kino, Motoki; Nagai, Hiroshi [National Astronomical Observatory of Japan, Osawa, Mitaka, Tokyo 181-8588 (Japan); Doi, Akihiro [Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency, 3-1-1 Yoshinodai, Chuo, Sagamihara 252-5210 (Japan); Hagiwara, Yoshiaki; Honma, Mareki; Kawaguchi, Noriyuki [Department of Astronomical Science, Graduate University for Advanced Studies (SOKENDAI), 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan)

    2012-11-20

    We report on the detailed radio status of the M 87 jet during the very high energy (VHE) {gamma}-ray flaring event in 2010 April, obtained from high-resolution, multi-frequency, phase-referencing Very Long Baseline Array observations. We especially focus on the properties of the jet base (the radio core) and the peculiar knot HST-1, which are currently favored as the {gamma}-ray emitting sites. During the VHE flaring event, the HST-1 region remains stable in terms of its structure and flux density in the optically thin regime above 2 GHz, being consistent with no signs of enhanced activities reported at X-ray for this feature. The radio core shows an inverted spectrum at least up to 43 GHz during this event. Astrometry of the core position, which is specified as {approx}20 R {sub s} from the central engine in our previous study, shows that the core position is stable on a level of 4 R {sub s}. The core at 43 and 22 GHz tends to show slightly ({approx}10%) higher flux level near the date of the VHE flux peak compared with the epochs before/after the event. The size of the 43 GHz core is estimated to be {approx}17 R {sub s}, which is close to the size of the emitting region suggested from the observed timescale of rapid variability at VHE. These results tend to favor the scenario that the VHE {gamma}-ray flare in 2010 April is associated with the radio core.

  17. Power output and efficiency of beta-emitting microspheres

    International Nuclear Information System (INIS)

    Cheneler, David; Ward, Michael

    2015-01-01

    Current standard methods to calculate the dose of radiation emitted during medical applications by beta-minus emitting microspheres rely on an over-simplistic formalism. This formalism is a function of the average activity of the radioisotope used and the physiological dimensions of the patient only. It neglects the variation in energy of the emitted beta particle due to self-attenuation, or self-absorption, effects related to the finite size of the sphere. Here it is assumed the sphere is comprised of a pure radioisotope with beta particles being emitted isotropically throughout the material. The full initial possible kinetic energy distribution of a beta particle is taken into account as well as the energy losses due to scattering by other atoms in the microsphere and bremsstrahlung radiation. By combining Longmire’s theory of the mean forward range of charged particles and the Rayleigh distribution to take into account the statistical nature of scattering and energy straggling, the linear attenuation, or self-absorption, coefficient for beta-emitting radioisotopes has been deduced. By analogy with gamma radiation transport in spheres, this result was used to calculate the rate of energy emitted by a beta-emitting microsphere and its efficiency. Comparisons to standard point dose kernel formulations generated using Monte Carlo data show the efficacy of the proposed method. Yttrium-90 is used as a specific example throughout, as a medically significant radioisotope, frequently used in radiation therapy for treating cancer. - Highlights: • Range-energy relationship for the beta particles in yttrium-90 is calculated. • Formalism for the semi-analytical calculation of self-absorption coefficients. • Energy-dependent self-absorption coefficient calculated for yttrium-90. • Flux rate of beta particles from a self-attenuating radioactive sphere is shown. • The efficiency of beta particle emitting radioactive microspheres is calculated

  18. Neutron-Activated Gamma-Emission: Technology Review

    Science.gov (United States)

    2012-01-01

    in Be9 + α  C12 + n and Be9 + α  3He4 + n. Chadwick (5) made use of the naturally occurring α-emitter polonium - 210 , which decays to lead-206 with...emission, the variation of gamma attenuation with distance and the presence of organic clutter (in food , fertilizer, dirt road, etc.) makes it 8...a neutron source by mixing a radioisotope that emits alpha particles, such as radium or polonium , with a low atomic weight isotope, usually in the

  19. Pharmacological evidences for DFK167-sensitive presenilin-independent gamma-secretase-like activity.

    Science.gov (United States)

    Sevalle, Jean; Ayral, Erwan; Hernandez, Jean-François; Martinez, Jean; Checler, Frédéric

    2009-07-01

    Amyloid-beta (Abeta) peptides production is thought to be a key event in the neurodegenerative process ultimately leading to Alzheimer's disease (AD) pathology. A bulk of studies concur to propose that the C-terminal moiety of Abeta is released from its precursor beta-amyloid precursor protein by a high molecular weight enzymatic complex referred to as gamma-secretase, that is composed of at least, nicastrin (NCT), Aph-1, Pen-2, and presenilins (PS) 1 or 2. They are thought to harbor the gamma-secretase catalytic activity. However, several lines of evidence suggest that additional gamma-secretase-like activities could potentially contribute to Abeta production. By means of a quenched fluorimetric substrate (JMV2660) mimicking the beta-amyloid precursor protein sequence targeted by gamma-secretase, we first show that as expected, this probe allows monitoring of an activity detectable in several cell systems including the neuronal cell line telencephalon specific murine neurons (TSM1). This activity is reduced by DFK167, N-[N-(3,5-difluorophenacetyl)-L-alanyl]-S-phenylglycine t-butyl ester (DAPT), and LY68458, three inhibitors known to functionally interact with PS. Interestingly, JMV2660 but not the unrelated peptide JMV2692, inhibits Abeta production in an in vitrogamma-secretase assay as expected from a putative substrate competitor. This activity is enhanced by PS1 and PS2 mutations known to be responsible for familial forms of AD and reduced by aspartyl mutations inactivating PS or in cells devoid of PS or NCT. However, we clearly establish that residual JMV2660-hydrolysing activity could be recovered in PS- and NCT-deficient fibroblasts and that this activity remained inhibited by DFK167. Overall, our study describes the presence of a proteolytic activity displaying gamma-secretase-like properties but independent of PS and still blocked by DFK167, suggesting that the PS-dependent complex could not be the unique gamma-secretase activity responsible for Abeta

  20. Multi-group transport methods for high-resolution neutron activation analysis

    International Nuclear Information System (INIS)

    Burns, K. A.; Smith, L. E.; Gesh, C. J.; Shaver, M. W.

    2009-01-01

    The accurate and efficient simulation of coupled neutron-photon problems is necessary for several important radiation detection applications. Examples include the detection of nuclear threats concealed in cargo containers and prompt gamma neutron activation analysis for nondestructive determination of elemental composition of unknown samples. In these applications, high-resolution gamma-ray spectrometers are used to preserve as much information as possible about the emitted photon flux, which consists of both continuum and characteristic gamma rays with discrete energies. Monte Carlo transport is the most commonly used modeling tool for this type of problem, but computational times for many problems can be prohibitive. This work explores the use of multi-group deterministic methods for the simulation of neutron activation problems. Central to this work is the development of a method for generating multi-group neutron-photon cross-sections in a way that separates the discrete and continuum photon emissions so that the key signatures in neutron activation analysis (i.e., the characteristic line energies) are preserved. The mechanics of the cross-section preparation method are described and contrasted with standard neutron-gamma cross-section sets. These custom cross-sections are then applied to several benchmark problems. Multi-group results for neutron and photon flux are compared to MCNP results. Finally, calculated responses of high-resolution spectrometers are compared. Preliminary findings show promising results when compared to MCNP. A detailed discussion of the potential benefits and shortcomings of the multi-group-based approach, in terms of accuracy, and computational efficiency, is provided. (authors)

  1. SBS 0846+513: a New Gamma-ray Emitting Narrow-line Seyfert 1 Galaxy

    Science.gov (United States)

    D'Ammando, F.; Orienti, M.; Finke, J.; Raiteri, C. M.; Angelakis, E.; Fuhrmann, L.; Giroletti, M.; Hovatta, T.; Max-Moerbeck, W.; Perkins, J. S.; hide

    2012-01-01

    We report Fermi-LAT observations of the radio-loud AGN SBS 0846+513 (z=0.5835), optically classified as a Narrow-Line Seyfert 1 galaxy, together with new and archival radio-to-X-ray data. The source was not active at ?-ray energies during the first two years of Fermi operation. A significant increase in activity was observed during 2010 October-2011 August. In particular a strong gamma-ray flare was observed in 2011 June reaching an isotropic ?-ray luminosity (0.1-300 GeV) of 1.0×10(sup 48) erg s(sup -1), comparable to that of the brightest flat spectrum radio quasars, and showing spectral evolution in gamma rays. An apparent superluminal velocity of (8.2+/-1.5)c in the jet was inferred from 2011-2012 VLBA images, suggesting the presence of a highly relativistic jet. Both the power released by this object during the flaring activity and the apparent superluminal velocity are strong indications of the presence of a relativistic jet as powerful as those of blazars. In addition, variability and spectral properties in radio and gamma-ray bands indicate blazar-like behaviour, suggesting that, except for some distinct optical characteristics, SBS 0846+513 could be considered as a young blazar at the low end of the blazar's black hole mass distribution.

  2. Cosmic very high-energy {gamma}-rays

    Energy Technology Data Exchange (ETDEWEB)

    Plaga, R. [Max-Planck-Institut fur Physik, Muenchen (Germany)

    1998-12-31

    The article gives a brief overview, aimed at nonspecialists, about the goals and selected recent results of the detection of very-high energy {gamma}-rays (energies above 100 GeV) with ground based detectors. The stress is on the physics questions, specially the origin of Galactic Cosmic Rays and the emission of TeV {gamma}-radiation from active galaxies. Moreover some particle-physics questions which are addressed in this area are discussed.

  3. Use of gamma spectroscopy in activation analysis; Utilisation de la spectrographie gamma dans l'analyse par activation

    Energy Technology Data Exchange (ETDEWEB)

    Leveque, [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    Brief review of the principles of activation analysis: calculation of activities, decay curves, {beta} absorption curves, examples of application. - Principle and description of the {gamma} spectrograph. - Practical utilisation of the {gamma} spectrograph: analysis by activation, analysis by {beta} - x fluorescence. - Sensitivity limit of the method and precision of the measurements. - Possible improvements to the method: {gamma} spectroscopy with elimination of the Compton effect. (author) [French] Bref rappel des principes de l'analyse par activation: calcul des activites, courbes de decroissance, courbes d'absorption {beta}, exemples d'utilisation. - Principe et description du spectrographe {gamma}. - Utilisation pratique de la spectrographie {gamma}: analyse par activation, analyse par fluorescence {beta} - x. - Limite de sensibilite de la methode et precision des mesures. - Ameliorations possibles de la methode: spectrographe {gamma} avec elimination de l'effet Compton. (auteur)

  4. Report on the IAEA-CU-2006-11 proficiency test on the determination of gamma emitting radionuclides in air filters

    International Nuclear Information System (INIS)

    Shakhashiro, A.; Kim, C.-K.; Sansone, U.; Ferrari, M.; Sill, D.

    2006-10-01

    This report summarises the results of the IAEA-CU-2006-11 proficiency test on the determination of gamma emitting radionuclides in air filters, organised within the frame of the IAEA Technical Cooperation project RER/8/009 ''Air Pollution Monitoring in the Mediterranean Region''. The proficiency test was conducted by the Reference Materials Group of the Chemistry Unit (Physics, Chemistry and Instrumentation Laboratory) of the IAEA's analytical laboratories located in Seibersdorf (Austria) in cooperation with the Radiological and Environmental Sciences Laboratory, Department of Energy in the United States of America. The objective of TC project RER/8/009 is to contribute to air quality improvement through the establishment of a network for air monitoring and the design of a remedial strategy where the monitoring shows poor air quality. A spiked air filter with known activities of gamma emitting radionuclides prepared by the Department of Energy of the United States of America was used in this proficiency test. 14 spiked filters were distributed to the participating laboratories in April 2006. The deadline for receiving the results from the participants was set at 31 July 2006. The participating laboratories were requested to analyse the samples employing the methods used in their routine work, so that their performance on the test samples could be directly related to the real performance of the laboratory. Each laboratory was given a confidential code to assure the anonymity of the evaluation results. From the 14 initially registered, 11 laboratories reported their results back to the IAEA. The analytical results of the participating laboratories were evaluated against the reference values assigned to the reference air filter, and a rating system was applied

  5. Relativistic motion in gamma-ray bursts

    International Nuclear Information System (INIS)

    Krolik, J.H.; Pier, E.A.

    1991-01-01

    Three fundamental problems affect models of gamma-ray bursts, i.e., the energy source, the ability of high-energy photons to escape the radiation region, and the comparative weakness of X-ray emission. It is indicated that relativistic bulk motion of the gamma-ray-emitting plasma generically provides a solution to all three of these problems. Results show that, if the plasma that produces gamma-ray bursts has a bulk relativistic velocity with Lorentz factor gamma of about 10, several of the most troubling problems having to do with gamma-ray bursts are solved. 42 refs

  6. The goals of gamma-ray spectroscopy in high energy astrophysics

    Science.gov (United States)

    Lingenfelter, Richard E.; Higdon, James C.; Leventhal, Marvin; Ramaty, Reuven; Woosley, Stanford E.

    1990-01-01

    The use of high resolution gamma-ray spectroscopy in astrophysics is discussed with specific attention given to the application of the Nuclear Astrophysics Explorer (NAE). The gamma-ray lines from nuclear transitions in radionucleic decay and positron annihilation permits the study of current sites, rates and models of nucleosynthesis, and galactic structure. Diffuse galactic emission is discussed, and the high-resolution observations of gamma-ray lines from discrete sites are also described. Interstellar mixing and elemental abundances can also be inferred from high-resolution gamma-ray spectroscopy of nucleosynthetic products. Compact objects can also be examined by means of gamma-ray emissions, allowing better understanding of neutron stars and the accreting black hole near the galactic center. Solar physics can also be investigated by examining such features as solar-flare particle acceleration and atmospheric abundances.

  7. Processing of gamma-ray spectrometric logs

    International Nuclear Information System (INIS)

    Umiastowski, K.; Dumesnil, P.

    1984-10-01

    CEA (Commissariat a l'Energie Atomique) has developped a gamma-ray spectrometric tool, containing an analog-to-digital converter. This new tool permits to perform very precise uranium logs (natural gamma-ray spectrometry), neutron activation logs and litho-density logs (gamma-gamma spectrometric logs). Specific processing methods were developped to treate the particular problems of down-hole gamma-ray spectrometry. Extraction of the characteristic gamma-ray peak, even if they are superposed on the background radiation of very high intensity, is possible. This processing methode enables also to obtain geological informations contained in the continuous background of the spectrum. Computer programs are written in high level language for SIRIUS (VICTOR) and APOLLO computers. Exemples of uranium and neutron activation logs treatment are presented [fr

  8. Detailed deposition density maps constructed by large-scale soil sampling for gamma-ray emitting radioactive nuclides from the Fukushima Dai-ichi Nuclear Power Plant accident.

    Science.gov (United States)

    Saito, Kimiaki; Tanihata, Isao; Fujiwara, Mamoru; Saito, Takashi; Shimoura, Susumu; Otsuka, Takaharu; Onda, Yuichi; Hoshi, Masaharu; Ikeuchi, Yoshihiro; Takahashi, Fumiaki; Kinouchi, Nobuyuki; Saegusa, Jun; Seki, Akiyuki; Takemiya, Hiroshi; Shibata, Tokushi

    2015-01-01

    Soil deposition density maps of gamma-ray emitting radioactive nuclides from the Fukushima Dai-ichi Nuclear Power Plant (NPP) accident were constructed on the basis of results from large-scale soil sampling. In total 10,915 soil samples were collected at 2168 locations. Gamma rays emitted from the samples were measured by Ge detectors and analyzed using a reliable unified method. The determined radioactivity was corrected to that of June 14, 2011 by considering the intrinsic decay constant of each nuclide. Finally the deposition maps were created for (134)Cs, (137)Cs, (131)I, (129m)Te and (110m)Ag. The radioactivity ratio of (134)Cs-(137)Cs was almost constant at 0.91 regardless of the locations of soil sampling. The radioactivity ratios of (131)I and (129m)Te-(137)Cs were relatively high in the regions south of the Fukushima NPP site. Effective doses for 50 y after the accident were evaluated for external and inhalation exposures due to the observed radioactive nuclides. The radiation doses from radioactive cesium were found to be much higher than those from the other radioactive nuclides. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Performance assessment of a NaI(Tl) gamma counter for PET applications with methods for improved quantitative accuracy and greater standardization

    OpenAIRE

    Lodge, Martin A; Holt, Daniel P; Kinahan, Paul E; Wong, Dean F; Wahl, Richard L

    2015-01-01

    Background Although NaI(Tl) gamma counters play an important role in many quantitative positron emission tomography (PET) protocols, their calibration for positron-emitting samples has not been standardized across imaging sites. In this study, we characterized the operational range of a gamma counter specifically for positron-emitting radionuclides, and we assessed the role of traceable 68Ge/68Ga sources for standardizing system calibration. Methods A NaI(Tl) gamma counter was characterized w...

  10. Comparative effects of exposure to high-energy electrons and gamma radiation on active avoidance behaviour

    International Nuclear Information System (INIS)

    Hunt, W.A.

    1983-01-01

    The effect of two types of ionizing radiation was examined on active avoidance behaviour. Male Sprague-Dawley rats were trained to avoid footshock by jumping onto a retractable ledge. When irradiated with high-energy electrons or gamma photons, their performance was degraded in a dose-dependent manner. However, electrons were 1.6 times as effective as gamma photons with ED50s of 62 and 102 Gy, respectively. All animals recovered within 24 min for all doses used. The data suggest that different types of ionizing radiation may not be equivalent when assessing their effect on behaviour. (author)

  11. High-Z Nanoparticle/Polymer Nanocomposites for Gamma-Ray Scintillation Detectors

    Science.gov (United States)

    Liu, Chao

    -Z inorganic nanoparticles. A facile single-precursor method is first developed to synthesize HfO2 nanoparticles, the highest-Z simple oxide with band gap larger than polyvinyltoluene, with uniform size distribution around 5 nm. A nanoparticle-surface-modification protocol is then developed for the fabrication of transparent nanocomposite monoliths with high nanoparticle loadings (up to 40 wt%). Using this method, transparent HfO2-loaded blue-emitting nanocomposite scintillators (2 mm thick, transmittance at 550 nm >75%) have been fabricated capable of producing a full energy photopeak for 662 keV gamma rays, with the best deconvoluted photopeak energy resolution production. The resulting nanocomposites thus exhibit unprecedented simultaneous enhancements in both light yield (visible photons produced per MeV of gamma photon energy) and gamma attenuation power. In a best demonstration, a 60 wt% quantum-dot nanocomposite scintillator exhibits a light yield of 9255 photons/MeV and a photopeak resolution of 9.8% under 662 keV Cs-137 gamma irradiation, demonstrating the potential of this model system for future high-performance low-cost spectroscopic gamma detectors.

  12. Use of a Shielded High Resolution Gamma Spectrometry System to Segregate LLW from Contact Handleable ILW Containing Plutonium - 13046

    Energy Technology Data Exchange (ETDEWEB)

    Lester, Rosemary; Wilkins, Colin [Canberra UK Ltd, Unit 1 B528.1, Harwell Science Campus, Oxfordshire OX11 0DF (United Kingdom); Chard, Patrick [Canberra UK Ltd, Forss Business and Technology park, Thurso, Caithness KW14 7UZ (United Kingdom); Jaederstroem, Henrik; LeBlanc, Paul; Mowry, Rick [Canberra Industries, Inc., 800 Research Parkway, Meriden, Connecticut, 06450 (United States); MacDonald, Sanders; Gunn, William [Dounreay Site Restoration Limited, Dounreay, Thurso, Caithness, KW14 7TZ (United Kingdom)

    2013-07-01

    Dounreay Site Restoration Limited (DSRL) have a number of drums of solid waste that may contain Plutonium Contaminated Material. These are currently categorised as Contact Handleable Intermediate Level Waste (CHILW). A significant fraction of these drums potentially contain waste that is in the Low Level Waste (LLW) category. A Canberra Q2 shielded high resolution gamma spectrometry system is being used to quantify the total activity of drums that are potentially in the LLW category in order to segregate those that do contain LLW from CHILW drums and thus to minimise the total volume of waste in the higher category. Am-241 is being used as an indicator of the presence of plutonium in the waste from its strong 59.54 keV gamma-ray; a knowledge of the different waste streams from which the material originates allows a pessimistic waste 'fingerprint' to be used in order to determine an upper limit to the activities of the weak and non-gamma-emitting plutonium and associated radionuclides. This paper describes the main features of the high resolution gamma spectrometry system being used by DSRL to perform the segregation of CHILW and LLW and how it was configured and calibrated using the Canberra In-Situ Object Counting System (ISOCS). It also describes how potential LLW drums are selected for assay and how the system uses the existing waste stream fingerprint information to determine a reliable upper limit for the total activity present in each measured drum. Results from the initial on-site commissioning trials and the first measurements of waste drums using the new monitor are presented. (authors)

  13. Annihilation gamma ray background characterization and rejection for a positron camera

    International Nuclear Information System (INIS)

    Levin, C.S.; Tornai, M.P.; MacDonald, L.R.

    1996-01-01

    We have developed a miniature (1.2 cm 2 ) beta-ray camera prototype to assist a surgeon in locating and removing the margins of a resected tumor. When imaging positron emitting radiopharmaceuticals, annihilation gamma ray interactions in the detector can mimic those of the betas. The extent of the background contamination depends on the detector, geometry and tumor specificity of the radiopharmaceutical. We have characterized the effects that annihilation gamma rays have on positron imaging with the camera. We studied beta and gamma ray detection rates and imaging using small positron or electron sources directly exposed to the detector to simulate hot tumor remnants and a cylinder filled with 18 F to simulate annihilation background from the brain. For various ratios of phantom brain/tumor activity, a annihilation gamma rate of 1.8 cts/sec/gCi was measured in the CaF 2 (Eu) detector. We present two gamma-ray background rejection schemes that use a β-γ coincidence. Results show that the coincidence methods works with ∼99% gamma ray rejection efficiency

  14. Radioactivity Measurement in the Detergent Products by Gamma Spectrometry

    International Nuclear Information System (INIS)

    Ksouri, Abir

    2009-01-01

    Our study focuses on the evaluation of the level of radioactivity in the detergents. We have determined the specific activities of gamma emitting radionuclides belonging to the natural families of uranium, thorium and potassium using gamma spectrometry. The activities of radionuclides ( 235 U, 238U , 226 Ra, 232 Th, 40K) and their descendants are below the minimum detectable activity for dishwasher products, soaps, bleaches and shampoos, whereas they are found to levels considered very low (between 0,2 and 13 Bq/kg on average) in the products washes linens. These values are always lower than those of raw materials, what is explained by the conservation of radioactive material throughout the manufacturing process. The effective dose due to external exposure estimated below the regulatory standard recommended (<1 mSv / year), allows us to show that detergent products are not contaminated by radioactivity, are healthy and do not have harmful radiological impact on the consumer.

  15. Application of neutron activation analysis method on biomonitors for assessing environment quality

    International Nuclear Information System (INIS)

    Nitescu, E. A.; Valeca, S.; Bucsa, A. F.

    2016-01-01

    The purpose of this paper is to determine the chemical elements concentrations which affect both the population health and environment, such as toxic agents which are contained in air and are retained by precipitation inside the biomonitors vegetal tissues. The Neutron Activation Analysis is an analytic technique based on measuring the numbers and the energy of gamma radiation emitted by the radioactive isotopes produced in the sample matrix by irradiation with thermal neutrons in a nuclear reactor [1]. Usually, the samples are irradiated together with specific neutron flux monitors, duplicates and interest elements standards for a prior selected period of time inside the core of nuclear reactor. After the irradiation experiment and the specific radioactive decaying, can proceed measuring the gamma energies spectrum by using a high resolution detection system (HPGe - High Purity Germanium crystal) for gamma spectrometry and then assess the impact of the traced elements on population and environment. (authors)

  16. Simple single-emitting layer hybrid white organic light emitting with high color stability

    Science.gov (United States)

    Nguyen, C.; Lu, Z. H.

    2017-10-01

    Simultaneously achieving a high efficiency and color quality at luminance levels required for solid-state lighting has been difficult for white organic light emitting diodes (OLEDs). Single-emitting layer (SEL) white OLEDs, in particular, exhibit a significant tradeoff between efficiency and color stability. Furthermore, despite the simplicity of SEL white OLEDs being its main advantage, the reported device structures are often complicated by the use of multiple blocking layers. In this paper, we report a highly simplified three-layered white OLED that achieves a low turn-on voltage of 2.7 V, an external quantum efficiency of 18.9% and power efficiency of 30 lm/W at 1000 cd/cm2. This simple white OLED also shows good color quality with a color rendering index of 75, CIE coordinates (0.42, 0.46), and little color shifting at high luminance. The device consists of a SEL sandwiched between a hole transport layer and an electron transport layer. The SEL comprises a thermally activated delayer fluorescent molecule having dual functions as a blue emitter and as a host for other lower energy emitters. The improved color stability and efficiency in such a simple device structure is explained as due to the elimination of significant energy barriers at various organic-organic interfaces in the traditional devices having multiple blocking layers.

  17. Carbonic anhydrase III regulates peroxisome proliferator-activated receptor-{gamma}2

    Energy Technology Data Exchange (ETDEWEB)

    Mitterberger, Maria C. [Cell Metabolism and Differentiation Research Group, Institute for Biomedical Aging Research of the Austrian Academy of Sciences, 6020 Innsbruck (Austria); Kim, Geumsoo [Laboratory of Biochemistry, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD 20892-8012 (United States); Rostek, Ursula [Cell Metabolism and Differentiation Research Group, Institute for Biomedical Aging Research of the Austrian Academy of Sciences, 6020 Innsbruck (Austria); Levine, Rodney L. [Laboratory of Biochemistry, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD 20892-8012 (United States); Zwerschke, Werner, E-mail: werner.zwerschke@oeaw.ac.at [Cell Metabolism and Differentiation Research Group, Institute for Biomedical Aging Research of the Austrian Academy of Sciences, 6020 Innsbruck (Austria)

    2012-05-01

    Carbonic anhydrase III (CAIII) is an isoenzyme of the CA family. Because of its low specific anhydrase activity, physiological functions in addition to hydrating CO{sub 2} have been proposed. CAIII expression is highly induced in adipogenesis and CAIII is the most abundant protein in adipose tissues. The function of CAIII in both preadipocytes and adipocytes is however unknown. In the present study we demonstrate that adipogenesis is greatly increased in mouse embryonic fibroblasts (MEFs) from CAIII knockout (KO) mice, as demonstrated by a greater than 10-fold increase in the induction of fatty acid-binding protein-4 (FABP4) and increased triglyceride formation in CAIII{sup -/-} MEFs compared with CAIII{sup +/+} cells. To address the underlying mechanism, we investigated the expression of the two adipogenic key regulators, peroxisome proliferator-activated receptor-{gamma}2 (PPAR{gamma}2) and CCAAT/enhancer binding protein-{alpha}. We found a considerable (approximately 1000-fold) increase in the PPAR{gamma}2 expression in the CAIII{sup -/-} MEFs. Furthermore, RNAi-mediated knockdown of endogenous CAIII in NIH 3T3-L1 preadipocytes resulted in a significant increase in the induction of PPAR{gamma}2 and FABP4. When both CAIII and PPAR{gamma}2 were knocked down, FABP4 was not induced. We conclude that down-regulation of CAIII in preadipocytes enhances adipogenesis and that CAIII is a regulator of adipogenic differentiation which acts at the level of PPAR{gamma}2 gene expression. -- Highlights: Black-Right-Pointing-Pointer We discover a novel function of Carbonic anhydrase III (CAIII). Black-Right-Pointing-Pointer We show that CAIII is a regulator of adipogenesis. Black-Right-Pointing-Pointer We demonstrate that CAIII acts at the level of PPAR{gamma}2 gene expression. Black-Right-Pointing-Pointer Our data contribute to a better understanding of the role of CAIII in fat tissue.

  18. The high intensity {gamma}-ray source (HI{gamma}S) and recent results

    Energy Technology Data Exchange (ETDEWEB)

    Tonchev, A.P. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States)]. E-mail: tonchev@tunl.duke.edu; Boswell, M. [University of North Carolina at Chapel Hill and TUNL, Chapel Hill, NC 27599 (United States); Howell, C.R. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States); Karwowski, H.J. [University of North Carolina at Chapel Hill and TUNL, Chapel Hill, NC 27599 (United States); Kelley, J.H. [North Carolina State University and TUNL, Raleigh, NC 27695 (United States); Tornow, W. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States); Wu, Y.K. [Duke University and Duke Free Electron Laser Laboratory, Durham, NC 27708-0319 (United States)

    2005-12-15

    The high intensity {gamma}-ray source (HI{gamma}S) utilizes intra-cavity backscattering of free electron laser photons from the Duke electron storage ring to produce a unique monoenergetic beam of high-flux {gamma}-rays with high polarization and selectable energy resolution. At present, {gamma}-ray beams with energies from 2 to 58 MeV are available with intensities as high as 10{sup 5}-5 x 10{sup 6} {gamma}/s, energy spreads of 3% or better, and nearly 100% linear polarization. The quality and intensity of the {gamma}-ray beams at HI{gamma}S are responsible for the unprecedented performance of this facility in a broad range of research programs in nuclear structure, nuclear astrophysics and nuclear applications. Recent results from excitation of isomeric states in ({gamma}, n) reactions and parity assignments of dipole states determined via the ({gamma}, {gamma}') reaction are presented.

  19. [Adenovirus-mediated canine interferon-gamma expression and its antiviral activity against canine parvovirus].

    Science.gov (United States)

    Zhang, Kao; Jin, Huijun; Zhong, Fei; Li, Xiujin; Neng, Changai; Chen, Huihui; Li, Wenyan; Wen, Jiexia

    2012-11-04

    To construct recombinant adenovirus containing canine interferon-gamma (cIFN-gamma) gene and to investigate its antiviral activity against canine parvovirus in Madin-Darby canine kidney cells (MDCK). [Methods] The cIFN-gamma gene was inserted into adenovirus shuttle plasmid to construct pShuttle3-cIFN-gamma expression vector, from which the cIFN-gamma expression cassette was transferred into the adenovirus genomic plasmid pAdeno-X by specific restriction sites to generate recombinant adenovirus genomic plasmid pAd-cIFN-gamma. The pAd-cIFN-gamma plasmid was linearized by digestion and transfected into human embryonic kidney (HEK) 293T cells to generate the replication-defective cIFN-gamma recombinant adenovirus (Ad-cIFN-gamma). To analyze its anti-canine parvovirus activity, the MDCK cells were pre-infected by Ad-cIFN-gamma recombinant adenovirus, and then infected by canine parvovirus. The antiviral activity of the Ad-cIFN-gamma recombinant adenovirus against parvovirus was analyzed. The recombinant adenovirus containing cIFN-gamma gene was constructed by the ligation method. The recombinant adenovirus could mediates recombinant cIFN-gamma secretory expression in MDCK cells. The Ad-cIFN-gamma recombinant adenovirus could significantly inhibit canine parvovirus replication in MDCK cells pre-infected with the recombinant adenovirus. These results indicate that the Ad-cIFN-gamma recombinant adenovirus has the potent antiviral activity against canine parvovirus. The Ad-cIFN-gamma recombinant adenovirus was successfully constructed by the ligation method and possessed a powerful antiviral activity against canine parvovirus.

  20. Measurement of gamma activity from the PUREX stack, Number 296-A-10, HEPA filters

    International Nuclear Information System (INIS)

    Barnett, J.M.

    1995-11-01

    In response to the Environmental Protection Agency's requirements for evaluating radioactive emissions from stacks, this test plan was developed. The test plan employs the use of low resolution (NaI) portable gamma spectrometry to identify and measure gamma emitting radionuclides from HEPA filters. The test description, expected results, and test set-up and steps are discussed

  1. A procedure for the production of steel exhibiting a low specific activity of gamma emitters

    International Nuclear Information System (INIS)

    Dolenek, J.; Raska, P.; Kodrle, L. et al.

    1989-01-01

    Steel exhibiting low specific gamma activity can be obtained from a metallic charge containing liquid and solid pig iron produced from ores, sinters, coke, limestone and other components. This charge is worked up in a metallurgical fining unit using predetermined amounts of slag-forming substances such as lime, limestone and dolomite; fining ore can also be present. The smelt must be kept in constant motion. The pig iron smelt for the production of this steel contains 0.1-1.1% Si and 0.1-1.0% Mn. All equipment with which the charge and steel will come in contact must be free from remains of previous productions and, preferrably, fitted with new lining. This concerns runners, pig iron transportation mixers, ladles and the production unit. (P.A.)

  2. HNF-1B specifically regulates the transcription of the {gamma}a-subunit of the Na{sup +}/K{sup +}-ATPase

    Energy Technology Data Exchange (ETDEWEB)

    Ferre, Silvia [Department of Physiology, Radboud University Nijmegen Medical Centre (Netherlands); Veenstra, Gert Jan C. [Department of Molecular Biology, Faculty of Science, Nijmegen Centre for Molecular Life Sciences, Radboud University Nijmegen (Netherlands); Bouwmeester, Rianne; Hoenderop, Joost G.J. [Department of Physiology, Radboud University Nijmegen Medical Centre (Netherlands); Bindels, Rene J.M., E-mail: r.bindels@fysiol.umcn.nl [Department of Physiology, Radboud University Nijmegen Medical Centre (Netherlands)

    2011-01-07

    Research highlights: {yields} Defects in HNF-1B transcription factor affect Mg{sup 2+} handling in the distal kidney. {yields} {gamma}a- and {gamma}b- subunits of the Na{sup +}/K{sup +}-ATPase colocalize in the distal convoluted tubule of the nephron. {yields} HNF-1B specifically activates {gamma}a expression. {yields} HNF-1B mutants have a dominant negative effect on wild type HNF-1B activity. {yields} Defective transcription of {gamma}a may promote renal Mg{sup 2+} wasting. -- Abstract: Hepatocyte nuclear factor-1B (HNF-1B) is a transcription factor involved in embryonic development and tissue-specific gene expression in several organs, including the kidney. Recently heterozygous mutations in the HNF1B gene have been identified in patients with hypomagnesemia due to renal Mg{sup 2+} wasting. Interestingly, ChIP-chip data revealed HNF-1B binding sites in the FXYD2 gene, encoding the {gamma}-subunit of the Na{sup +}/K{sup +}-ATPase. The {gamma}-subunit has been described as one of the molecular players in the renal Mg{sup 2+} reabsorption in the distal convoluted tubule (DCT). Of note, the FXYD2 gene can be alternatively transcribed into two main variants, namely {gamma}a and {gamma}b. In the present study, we demonstrated via two different reporter gene assays that HNF-1B specifically acts as an activator of the {gamma}a-subunit, whereas the {gamma}b-subunit expression was not affected. Moreover, the HNF-1B mutations H69fsdelAC, H324S325fsdelCA, Y352finsA and K156E, previously identified in patients with hypomagnesemia, prevented transcription activation of {gamma}a-subunit via a dominant negative effect on wild type HNF1-B. By immunohistochemistry, it was shown that the {gamma}a- and {gamma}b-subunits colocalize at the basolateral membrane of the DCT segment of mouse kidney. On the basis of these data, we suggest that abnormalities involving the HNF-1B gene may impair the relative abundance of {gamma}a and {gamma}b, thus affecting the transcellular Mg{sup 2

  3. SYSTEMATIC STUDY OF GAMMA-RAY-BRIGHT BLAZARS WITH OPTICAL POLARIZATION AND GAMMA-RAY VARIABILITY

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Ryosuke; Fukazawa, Yasushi; Kanda, Yuka; Shiki, Kensei; Kawabata, Miho; Nakaoka, Tatsuya; Takaki, Katsutoshi; Takata, Koji; Ui, Takahiro [Department of Physical Science, Hiroshima University, Higashi-Hiroshima, Hiroshima 739-8526 (Japan); Nalewajko, Krzysztof; Madejski, Greg M. [Kavli Institute for Particle Astrophysics and Cosmology, SLAC National Accelerator Laboratory, Stanford University, 2575 Sand Hill Road M/S 29, Menlo Park, CA 94025 (United States); Uemura, Makoto; Tanaka, Yasuyuki T.; Kawabata, Koji S.; Akitaya, Hiroshi; Ohsugi, Takashi [Hiroshima Astrophysical Science Center, Hiroshima University, Higashi-Hiroshima, Hiroshima 739-8526 (Japan); Schinzel, Frank K. [Department of Physics and Astronomy, University of New Mexico, Albuquerque, NM 87131 (United States); Moritani, Yuki [Kavli Institute for the Physics and Mathematics of the Universe (WPI), The University of Tokyo Institutes for Advanced Study, The University of Tokyo, Kashiwa, Chiba 277-8583 (Japan); Sasada, Mahito [Institute for Astrophysical Research, Boston University, 725 Commonwealth Avenue, Boston, MA 02215 (United States); Yamanaka, Masayuki, E-mail: itoh@hep01.hepl.hiroshima-u.ac.jp, E-mail: itoh@hp.phys.titech.ac.jp [Department of Physics, Faculty of Science and Engineering, Konan University, Okamoto, Kobe, Hyogo 658-8501 (Japan); and others

    2016-12-10

    Blazars are highly variable active galactic nuclei that emit radiation at all wavelengths from radio to gamma rays. Polarized radiation from blazars is one key piece of evidence for synchrotron radiation at low energies, and it also varies dramatically. The polarization of blazars is of interest for understanding the origin, confinement, and propagation of jets. However, even though numerous measurements have been performed, the mechanisms behind jet creation, composition, and variability are still debated. We performed simultaneous gamma-ray and optical photopolarimetry observations of 45 blazars between 2008 July and 2014 December to investigate the mechanisms of variability and search for a basic relation between the several subclasses of blazars. We identify a correlation between the maximum degree of optical linear polarization and the gamma-ray luminosity or the ratio of gamma-ray to optical fluxes. Since the maximum polarization degree depends on the condition of the magnetic field (chaotic or ordered), this result implies a systematic difference in the intrinsic alignment of magnetic fields in parsec-scale relativistic jets between different types of blazars (flat-spectrum radio quasars vs. BL Lacs) and consequently between different types of radio galaxies (FR I versus FR II).

  4. Dependency of {gamma}-secretase complex activity on the structural integrity of the bilayer

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Hua, E-mail: hzhou2@lbl.gov [Life Sciences Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, CA 94720 (United States); Zhou, Shuxia; Walian, Peter J.; Jap, Bing K. [Life Sciences Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, CA 94720 (United States)

    2010-11-12

    Research highlights: {yields} Partial solubilization of membranes with CHAPSO can increase {gamma}-secretase activity. {yields} Completely solubilized {gamma}-secretase is inactive. {yields} Purified {gamma}-secretase regains activity after reconstitution into lipid bilayers. {yields} A broad range of detergents can be used to successfully reconstitute {gamma}-secretase. -- Abstract: {gamma}-secretase is a membrane protein complex associated with the production of A{beta} peptides that are pathogenic in Alzheimer's disease. We have characterized the activity of {gamma}-secretase complexes under a variety of detergent solubilization and reconstitution conditions, and the structural state of proteoliposomes by electron microscopy. We found that {gamma}-secretase activity is highly dependent on the physical state or integrity of the membrane bilayer - partial solubilization may increase activity while complete solubilization will abolish it. The activity of well-solubilized {gamma}-secretase can be restored to near native levels when properly reconstituted into a lipid bilayer environment.

  5. Very high-energy gamma rays from gamma-ray bursts.

    Science.gov (United States)

    Chadwick, Paula M

    2007-05-15

    Very high-energy (VHE) gamma-ray astronomy has undergone a transformation in the last few years, with telescopes of unprecedented sensitivity having greatly expanded the source catalogue. Such progress makes the detection of a gamma-ray burst at the highest energies much more likely than previously. This paper describes the facilities currently operating and their chances for detecting gamma-ray bursts, and reviews predictions for VHE gamma-ray emission from gamma-ray bursts. Results to date are summarized.

  6. Some problems of the detection of the high energy gamma-radiation in space

    Science.gov (United States)

    Fradkin, M. I.; Ginzburg, V. L.; Kurnosova, L. V.; Labensky, A. G.; Razorenov, L. A.; Rusakovich, M. A.; Topchiev, N. P.; Kaplin, V. A.; Runtso, M. F.; Gorchakov, E. V.; Ignatiev, P. P.

    1995-05-01

    Diffuse gamma radiation in the Galaxy has been measured with instruments onboard the COS-B and Compton Gamma Ray Observatory (CGRO) satellites from the tens of keV up to about 30 GeV. There is no experimental data at higher energies, but this data is very important for the spectrum of primary cosmic rays and the existence of neutralinos (hypothetical supersymmetrical particles which are supposed to constitute dark matter in the Galaxy and create gamma-quanta in the process of annihilation). The GAMMA-400 collaboration is working on the design of a telescope for gamma-ray measurements in the 10-1000 GeV range. The electronics of the GAMMA-400 eliminate some hindering effects, in particular the influence of backscattered gammas emitted by the very massive calorimeter (calorimeter albedo). The GAMMA-400 project may be realized in the near future if economic conditions in Russia are favorable.

  7. Process and device for monitoring active and highly active liquids for specific nuclides, particularly in the primary coolant of boiling water and pressurized water reactors

    International Nuclear Information System (INIS)

    Paffrath; Haag; Hanstein, W.

    1986-01-01

    The invention provides for a direct continuous measurement of amounts of activity or concentration and the automatic execution of analysis cycles for specific nuclides, which occur depending on the continuously determined total gamma value. The continuously determined total gamma values in a first measuring circuit are used to decide the frequency of sampling, the volume of samples, the measuring times, the doses of separating chemicals and the sample remnants. These parameters are provided for the control of the execution of an analysis cycle for specific nuclides occurring in a second measuring circuit. (orig./HP) [de

  8. Cytotoxic activities of amentoflavone against human breast and cervical cancers are mediated by increasing of PTEN expression levels due to peroxisomes proliferate-activated receptor {gamma} activation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eunjung; Shin, Soyoung; Lee, Jeeyoung; Lee, So Jung; Kim, Jinkyoung; Yoon, Doyoung; Kim, Yangmee [Konkuk Univ., Seoul (Korea, Republic of); Woo, Eunrhan [Chosun Univ., Gwangju (Korea, Republic of)

    2012-07-15

    Human peroxisomes proliferate-activated receptor gamma (hPPAR{gamma}) has been implicated in numerous pathologies, including obesity, diabetes, and cancer. Previously, we verified that amentoflavone is an activator of hPPAR{gamma} and probed the molecular basis of its action. In this study, we investigated the mechanism of action of amentoflavone in cancer cells and demonstrated that amentoflavone showed strong cytotoxicity against MCF-7 and HeLa cancer cell lines. We showed that hPPAR{gamma} expression in MCF-7 and HeLa cells is specifically stimulated by amentoflavone, and suggested that amentoflavone-induced cytotoxic activities are mediated by activation of hPPAR{gamma} in these two cancer cell lines. Moreover, amentoflavone increased PTEN levels in these two cancer cell lines, indicating that the cytotoxic activities of amentoflavone are mediated by increasing of PTEN expression levels due to hPPAR{gamma} activation.

  9. Characterization of the neutron flow for the implementation of an experimental analysis installation for rapid gamma activation in the Argentine Research Reactor RA-6

    International Nuclear Information System (INIS)

    Henriquez, C.; Gennuso, G.

    2000-01-01

    This is the final work to obtain a Diploma on Specialization in Application of Nuclear Technological Energy, carried out at the Research Reactor RA-6, from March to December 1999. Different work has been realized on the Tangential Tube N of the 500 KW Argentine RA-6 research reactor, in order to add a new technique to the present existing analytical methods. This Prompt Gamma Neutron Activation Analysis technique (PGNAA) requires a beam of collimated thermal neutrons, a lowest possible gamma radiation, and a thermal component of the biggest possible cadmium rate. It also must have a high resolution detection system for the measurement of the gamma radiation emitted after the capture of the neutron produced in the study sample. Continuing with the facility's technical requirements, a collimator was installed inside the N passing tube, in order to concentrate the neutrons coming from the nuclear core and also to compensate possible losses during the path. This collimator is 440mm long and 200 mm in diameter and consists of lead and steel cylinders with different size holes on the inside, so that it can deliver a 50 mm diameter beam of thermal collimated neutrons. Two 100 mm thick bismuth filters are inside the passing tube, to reduce the gamma component inside de beam, coming from the reactor core. This work aims to the characterization of the thermal and epithermal component of the neutron beam in the collimator and at the exit of it , and also to prove experimentally that the collimator achieves the technical specifications for which it was designed and built, specifically by verifying its functioning (degree of convergence of the beam obtained). On the other hand, it is necessary to learn about the PGNAA technique in order to define the technical requirements for its adequate operation. (author)

  10. Chemical composition and lipoxygenase activity in soybeans (Glycine max L. Merr.) submitted to gamma irradiation

    Science.gov (United States)

    Barros, Érica Amanda de; Broetto, Fernando; Bressan, Dayanne F.; Sartori, Maria M. P.; Costa, Vladimir E.

    2014-05-01

    Soybeans are an important food due to their functional and nutritional characteristics. However, consumption by western populations is limited by the astringent taste of soybeans and their derivatives which results from the action of lipoxygenase, an enzyme activated during product processing. The aim of this study was to evaluate the effect of gamma irradiation on the chemical composition and specific activity of lipoxygenase in different soybean cultivars. Soybeans were stored in plastic bags and irradiated with doses of 2.5, 5 and 10 kGy. The chemical composition (moisture, protein, lipids, ashes, crude fiber, and carbohydrates) and lipoxygenase specific activity were determined for each sample. Gamma irradiation induced a small increase of protein and lipid content in some soybean cultivars, which did not exceed the highest content of 5% and 26%, respectively, when compared to control. Lipoxygenase specific activity decreased in the three cultivars with increasing gamma irradiation dose. In conclusion, the gamma irradiation doses used are suitable to inactivate part of lipoxygenase while not causing expressive changes in the chemical composition of the cultivars studied.

  11. Synthesis of high specific activity tritium labelled compounds

    International Nuclear Information System (INIS)

    Parent, P.

    1986-01-01

    Tritiated methyl iodide of high specific activity is synthetized by Fischer-Tropsch reaction of tritium with carbon monoxide, tritiated methanol obtained is reacted with hydriodic acid. It is used for the synthesis of S-adenosyl L-methionine 3 H-methyl and of diazepam 3 H-methyl derivatives. Synthesis of 3-PPP 3 H: (hydroxy-3 phenyl)-3N-n propyl [ 3 H-2.3] piperidine [ 3 H-2.3] with a specific activity of 4.25 T Bq/mM (115 Ci/mM) and of baclofene 3 H with a specific activity of 0.925 TBq (25 Ci/mM) are also described [fr

  12. Comparative uptake of gamma-emitting fission product nuclides by plants

    International Nuclear Information System (INIS)

    D'souza, T.J.; Mistry, K.B.

    1974-01-01

    The comparative uptake of long-lived gamma-emitting fission product nuclides 106 Ru, 125 Sb, 137 Cs and 144 Ce, present in global fallout from nuclear explosions, by maize (Zea mays L) plants was examined in water culture experiments. Over identical duration of plant growth, the extent of accumulation of the radionuclides in aerial tissues was in the following decreasing order: 137 Cs >, 125 Sb >, 106 Ru > and 144 Ce. In roots, however, the retention of 144 Ce and 106 Ru was greater than that of 137 Cs and 125 Sb. Complementary studies with maize and rice (Oryza sativa L) grown on two contrasting soil types, namely, laterite and black clay loam indicated that 137 Cs uptake by plants was markedly greater than that of the other radionuclides in both soil types. Plant uptake of 106 Ru and 125 Sb was significantly higher than that of 144 Ce in the black soil. In the laterite, however, 144 Ce uptake far exceeded that of 106 Ru and 125 Sb. In general, maize removed higher amounts of the radionuclides than rice from both soil types. (author)

  13. Chemical synthesis of high specific-activity [35S]adenosylhomocysteine

    International Nuclear Information System (INIS)

    Stern, P.H.; Hoffman, R.M.

    1986-01-01

    The study of the family of transmethylases, critical to normal cellular function and often altered in cancer, can be facilitated by the availability of a high specific-activity S-adenosylhomocysteine. The authors report the two-step preparation of [ 35 S]adenosylhomocysteine from [ 35 S]methionine at a specific activity of 1420 Ci/mmol in an overall yield of 24% by a procedure involving demethylation of the [ 35 S]methionine to [ 35 S]homocysteine followed by condensation with 5'-chloro-5'-deoxyadenosine. The ease of the reactions, ready availability and low cost of the reagents and high specific-activity and stability of the product make the procedure an attractive one with many uses, and superior to current methodology

  14. 3.4-Inch Quarter High Definition Flexible Active Matrix Organic Light Emitting Display with Oxide Thin Film Transistor

    Science.gov (United States)

    Hatano, Kaoru; Chida, Akihiro; Okano, Tatsuya; Sugisawa, Nozomu; Inoue, Tatsunori; Seo, Satoshi; Suzuki, Kunihiko; Oikawa, Yoshiaki; Miyake, Hiroyuki; Koyama, Jun; Yamazaki, Shunpei; Eguchi, Shingo; Katayama, Masahiro; Sakakura, Masayuki

    2011-03-01

    In this paper, we report a 3.4-in. flexible active matrix organic light emitting display (AMOLED) display with remarkably high definition (quarter high definition: QHD) in which oxide thin film transistors (TFTs) are used. We have developed a transfer technology in which a TFT array formed on a glass substrate is separated from the substrate by physical force and then attached to a flexible plastic substrate. Unlike a normal process in which a TFT array is directly fabricated on a thin plastic substrate, our transfer technology permits a high integration of high performance TFTs, such as low-temperature polycrystalline silicon TFTs (LTPS TFTs) and oxide TFTs, on a plastic substrate, because a flat, rigid, and thermally-stable glass substrate can be used in the TFT fabrication process in our transfer technology. As a result, this technology realized an oxide TFT array for an AMOLED on a plastic substrate. Furthermore, in order to achieve a high-definition AMOLED, color filters were incorporated in the TFT array and a white organic light-emitting diode (OLED) was combined. One of the features of this device is that the whole body of the device can be bent freely because a source driver and a gate driver can be integrated on the substrate due to the high mobility of an oxide TFT. This feature means “true” flexibility.

  15. Induced Gamma-Band Activity and Fixational Eye Movements are Differentially Influenced by Low-and High-Level Factors in a Visual Object Classification Task

    Directory of Open Access Journals (Sweden)

    J Martinovic

    2011-04-01

    Full Text Available Until recently induced high frequency oscillatory activity (gamma-band activity; >30 Hz was considered a neural marker of cortical object representation. However, Yuval-Greenberg et al (2008; Neuron demonstrated that induced gamma-band activity (GBA in the elecetroencephalogram (EEG is susceptible to artifacts caused by miniature eye movements, which account for the major part of the signal in the crucial time window of 200-400 ms after stimulus onset. Is there an underlying cortical-induced gamma-band response that is obscured by ocular artifacts but can still be recorded with EEG? Furthermore, if object-specific modulations of induced GBA in previous studies were caused by ocular artifacts, should we instead study fixational eye movements as a response that can reflect higher-level representational processes in vision? In order to investigate this, we conducted an eye tracking experiment and an EEG experiment using the same design. Participants were asked to classify line drawings of objects or non-objects. To introduce low-level differences, their contours were defined along different directions in cardinal colour space: 1 S-cone-isolating (S, or 2 intermediate isoluminant (S and L-M, or 3 a full-colour stimulus, containing an additional achromatic component (S; L-M; L+M+S. In both experiments, behavioural performance was optimal for full-colour stimuli. In the eye tracking experiment, fixational eye movement rates 200-400 ms after stimulus onset depended on low-level factors, with no difference between objects and non-objects. In the EEG experiment, miniature eye movements were identified and removed using the saccadic filter approach. The artifact-free induced GBA exhibited a lateralised distribution, with enhancements at left and right posterior sites. Activity was higher for full-colour objects on the left, with the opposite effect observed on the right. We conclude that induced GBA can be observed in the EEG. While it showed high

  16. Measurement of high dose rates of 60Co by gamma activation of115In and 111Cd foils

    International Nuclear Information System (INIS)

    Haddad, Kh; Qattan, M.; Taleb, A.

    2009-12-01

    The high gamma dose rate measurement technique using nuclear reaction (γ,(γ ' ') was introduced in this work. This technique is cheap, easy, reliable, and independent of chemical and physical factors, which affect other techniques. The response to the absorbed dose in this technique is linear and can be used for high dose. Cd and In foils were irradiated using 60 Co source and the resulted isomer activities were measured using gamma spectrometer. These foils were calibrated to be used as dosemeter and its results were compared with conventional one. The dose distribution in the irradiation field was determined using In foils. (authors)

  17. High-sensitivity gamma spectroscopy for extended sources. Application to activity measurements on the human body, on glass, and on soil; Spectrographie gamma a grande sensibilite pour sources etendues. Application a la mesure de l'activite du corps humain, du verre et du sol

    Energy Technology Data Exchange (ETDEWEB)

    Jouve, B

    1962-07-01

    The measurement and location by gamma spectroscopy of human body internal contaminations at maximum permissible levels, and, in certain cases, at lower activities such as that due to {sup 40}K was investigated. The characteristics of the high-sensitivity apparatus used are given, and several assemblies using large-volume NaI(Tl) scintillators are described. The relatively light shielding required for natural radioactivity permitted construction of mobile assembly. Conditions of use are described, and the results are given. All gamma emitting elements were measured in 15 min at levels lower than the tolerance dose. Gamma spectroscopy was also used to determine fission products in the earth and to study radioactive elements in the presence of other emitters. (author) [French] La spectrographie gamma du corps humain permet la mesure et la localisation des contaminations internes au niveau des doses de tolerance et, dans certains cas, celle d'activites plus faibles comme la radioactivite naturelle due principalement au potassium 40. Les caracteristiques des appareils a grande sensibilite permettant ces mesures sont exposees et on decrit plusieurs realisations originales utilisant un scintillateur NaI(Tl) de grand volume. L'epaisseur du blindage a ete limitee a 5 cm de plomb, ainsi, pour une protection suffisante contre les rayonnements ambiants, les appareils sont relativement legers et l'une des realisations a pu etre installee dans un laboratoire mobile. Les conditions d'utilisation (mouvement propre, etalonnage) et les resultats obtenus sont donnes; tous les radioelements emetteurs gamma sont mesurables en 15 minutes a un niveau inferieur a la dose de tolerance. On presente enfin des applications a la spectrographie gamma d'echantillons volumineux (poudres ou liquides) et de tres faible activite: elles interessent des domaines tres varies comme, par exemple, la geophysique (etude des retombees radioactives) ou l'industrie chimique (dosage du potassium dans les

  18. The Radio/Gamma-Ray Connection from 120 MHz to 230 GHz

    Directory of Open Access Journals (Sweden)

    Marcello Giroletti

    2016-09-01

    Full Text Available Radio loud active galactic nuclei are composed of different spatial features, each one characterized by different spectral properties in the radio band. Among them, blazars are the most common class of sources detected at gamma-rays by Fermi, and their radio emission is dominated by the flat spectrum compact core. In this contribution, we explore the connection between emission at high energy revealed by Fermi and at radio frequencies. Taking as a reference the strong and very highly significant correlation found between gamma rays and cm-λ radio emission, we explore the different behaviours found as we change the energy range in gamma rays and in radio, therefore changing the physical parameters of the zones involved in the emitted radiation. We find that the correlation weakens when we consider (1 gamma rays of energy above 10 GeV (except for high synchrotron peaked blazars or (2 low frequency radio data taken by the Murchison Widefield Array; on the other hand, the correlation strengthens when we consider mm-λ data taken by Atacama Large Millimeter Array (ALMA.

  19. THE PROBLEMS OF USING EXEMPTION ACTIVITY VALUES FOR REGULATING THE MANAGEMENT OF SEALED RADIONUCLIDE SOURCES OF GAMMA-RADIATION

    Directory of Open Access Journals (Sweden)

    A. N. Barkovsky

    2017-01-01

    Full Text Available The article focuses on the procedure for exemption of the sealed and unsealed radionuclide sources of gamma radiation from regulatory control. The contradictory nature of the existing set of exemption criteria has been noted, leading, in some cases, to paradoxical situations. It is shown that the exempt activity values determined in NRB-99/2009 and in the international basic safety standards of the IAEA are significantly overestimated (in comparison with the activity values of a point source creating the ambient dose equivalent rate of 1 μSv / h at a distance of 0.1 m for a number of the most widely used gamma-emitting radionuclides, including 22Na, 54Mn, 75Se, 152Eu and 154Eu. It is proposed to revise the current values of exempt activity, bringing them in line with the dose rate criterion for the exempt of sealed radionuclide sources of gamma radiation, and to present them with one significant digit. The corrected values of exempt activity for  seven selected radionuclides are proposed for further use in the process of revision of the national radiation safety standards.

  20. Benchmark studies of induced radioactivity produced in LHC materials, Part I: Specific activities.

    Science.gov (United States)

    Brugger, M; Khater, H; Mayer, S; Prinz, A; Roesler, S; Ulrici, L; Vincke, H

    2005-01-01

    Samples of materials which will be used in the LHC machine for shielding and construction components were irradiated in the stray radiation field of the CERN-EU high-energy reference field facility. After irradiation, the specific activities induced in the various samples were analysed with a high-precision gamma spectrometer at various cooling times, allowing identification of isotopes with a wide range of half-lives. Furthermore, the irradiation experiment was simulated in detail with the FLUKA Monte Carlo code. A comparison of measured and calculated specific activities shows good agreement, supporting the use of FLUKA for estimating the level of induced activity in the LHC.

  1. Benchmark studies of induced radioactivity produced in LHC materials, part I: Specific activities

    International Nuclear Information System (INIS)

    Brugger, M.; Khater, H.; Mayer, S.; Prinz, A.; Roesler, S.; Ulrici, L.; Vincke, H.

    2005-01-01

    Samples of materials which will be used in the LHC machine for shielding and construction components were irradiated in the stray radiation field of the CERN-EU high-energy reference field facility. After irradiation, the specific activities induced in the various samples were analysed with a high-precision gamma spectrometer at various cooling times, allowing identification of isotopes with a wide range of half-lives. Furthermore, the irradiation experiment was simulated in detail with the FLUKA Monte Carlo code. A comparison of measured and calculated specific activities shows good agreement, supporting the use of FLUKA for estimating the level of induced activity in the LHC. (authors)

  2. Experienced Mindfulness Meditators Exhibit Higher Parietal-Occipital EEG Gamma Activity during NREM Sleep

    Science.gov (United States)

    Ferrarelli, Fabio; Smith, Richard; Dentico, Daniela; Riedner, Brady A.; Zennig, Corinna; Benca, Ruth M.; Lutz, Antoine; Davidson, Richard J.; Tononi, Giulio

    2013-01-01

    Over the past several years meditation practice has gained increasing attention as a non-pharmacological intervention to provide health related benefits, from promoting general wellness to alleviating the symptoms of a variety of medical conditions. However, the effects of meditation training on brain activity still need to be fully characterized. Sleep provides a unique approach to explore the meditation-related plastic changes in brain function. In this study we performed sleep high-density electroencephalographic (hdEEG) recordings in long-term meditators (LTM) of Buddhist meditation practices (approximately 8700 mean hours of life practice) and meditation naive individuals. We found that LTM had increased parietal-occipital EEG gamma power during NREM sleep. This increase was specific for the gamma range (25–40 Hz), was not related to the level of spontaneous arousal during NREM and was positively correlated with the length of lifetime daily meditation practice. Altogether, these findings indicate that meditation practice produces measurable changes in spontaneous brain activity, and suggest that EEG gamma activity during sleep represents a sensitive measure of the long-lasting, plastic effects of meditative training on brain function. PMID:24015304

  3. Preparation of high specific activity labelled triiodothyronine (T3) for radioimmunoassay

    International Nuclear Information System (INIS)

    Pillai, M.R.A.; Nagvekar, U.H.; Desai, C.N.; Mani, R.S.

    1981-01-01

    A method standardized for the preparation of high specific activity labelled triiodothyronine (T 3 ) is discussed. Iodine-125 labelled T 3 with a specific activity of 3 mCi μg was prepared by iodinating 3,5-diiodothyronine (T 2 ) and purifying it over Sephadex G-25 gel. Radochemical purity and stability evaluations were done by paper chromatography. Specific activity of the labelled T 3 prepared was estimated by the self-displacement method. The use of this high specific activity labelled T 3 in radioimmunoassay increased the sensitivity considerably. The advantage of this procedure is that the specific activity of labelled T 3 formed is independent of reaction yield and labelled T 3 yield. (author)

  4. Gender- and age-dependent gamma-secretase activity in mouse brain and its implication in sporadic Alzheimer disease.

    Directory of Open Access Journals (Sweden)

    Lisa Placanica

    Full Text Available Alzheimer disease (AD is an age-related disorder. Aging and female gender are two important risk factors associated with sporadic AD. However, the mechanism by which aging and gender contribute to the pathogenesis of sporadic AD is unclear. It is well known that genetic mutations in gamma-secretase result in rare forms of early onset AD due to the aberrant production of Abeta42 peptides, which are the major constituents of senile plaques. However, the effect of age and gender on gamma-secretase has not been fully investigated. Here, using normal wild-type mice, we show mouse brain gamma-secretase exhibits gender- and age-dependent activity. Both male and female mice exhibit increased Abeta42ratioAbeta40 ratios in aged brain, which mimics the effect of familial mutations of Presenilin-1, Presenlin-2, and the amyloid precursor protein on Abeta production. Additionally, female mice exhibit much higher gamma-secretase activity in aged brain compared to male mice. Furthermore, both male and female mice exhibit a steady decline in Notch1 gamma-secretase activity with aging. Using a small molecule affinity probe we demonstrate that male mice have less active gamma-secretase complexes than female mice, which may account for the gender-associated differences in activity in aged brain. These findings demonstrate that aging can affect gamma-secretase activity and specificity, suggesting a role for gamma-secretase in sporadic AD. Furthermore, the increased APP gamma-secretase activity seen in aged females may contribute to the increased incidence of sporadic AD in women and the aggressive Abeta plaque pathology seen in female mouse models of AD. In addition, deceased Notch gamma-secretase activity may also contribute to neurodegeneration. Therefore, this study implicates altered gamma-secretase activity and specificity as a possible mechanism of sporadic AD during aging.

  5. Initial Gamma Spectrometry Examination of the AGR-3/4 Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Harp, Jason M.; Demkowicz, Paul A.; Stempien, John D.

    2016-11-01

    The initial results from gamma spectrometry examination of the different components from the combined third and fourth US Advanced Gas Reactor Fuel Development TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail particles surrounded by two graphitic diffusion rings (inner and outer) and a graphite sink were irradiated in the Idaho National Laboratory’s Advanced Test Reactor. Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. Additionally, inner and outer rings were also examined by gamma spectrometry both to evaluate the fission product inventory and the distribution of gamma-emitting fission products within the rings using gamma emission computed tomography. The cesium inventory of the scanned rings compares acceptably well with the expected inventory from fission product transport modeling. The inventory of the graphite fission product sinks is also being evaluated by gamma spectrometry.

  6. Examining the nature of very-high-energy gamma-ray emission from the AGN PKS 1222+216 and 3C 279

    Science.gov (United States)

    Price, Sharleen; Brill, Ari; Mukherjee, Reshmi; VERITAS

    2018-01-01

    Blazars are a type of active galactic nuclei (AGN) that emit jets of ionized matter which move towards the Earth at relativistic speeds. In this research we carried out a study of two objects, 3C 279 and PKS 1222+216, which belong to the subset of blazars known as FSRQs (flat spectrum radio quasars), the most powerful TeV-detected sources at gamma-ray energies with bolometric luminosities exceeding 1048 erg/s. The high-energy emission of quasars peaks in the MeV-GeV band, making these sources very rarely detectable in the TeV energy range. In fact, only six FSRQs have ever been detected in this range by very-high-energy gamma-ray telescopes. We will present results from observing campaigns on 3C 279 in 2014 and 2016, when the object was detected in high flux states by Fermi-LAT. Observations include simultaneous coverage with the Fermi-LAT satellite and the VERITAS ground-based array spanning four decades in energy from 100 MeV to 1 TeV. We will also report VERITAS observations of PKS 1222+216 between 2008 and 2017. The detection/non-detection of TeV emission during flaring episodes at MeV energies will further contribute to our understanding of particle acceleration and gamma-ray emission mechanisms in blazar jets.

  7. Evaluation of gamma activities of naturally occurring radioactive materials in uncontaminated surface soils of Jamaica

    International Nuclear Information System (INIS)

    Maurice Miller; Mitko Voutchkov

    2014-01-01

    In this study a geological, lithological or pedogenesis analysis is used to explain the values and distribution of the primordial specific gamma activities in the Jamaican soil environment. A random systematic sampling method resulted in Jamaica being divided into 50 square grids with a maximum sampling density of 225 square meters per sample. The resulting sixty-eight (68) samples were measured on a Canberra HPGe detector for 24 h and the photopeaks for the primordial gammas of 238 U, 232 Th and 40 K analyzed. Spearman's correlation was used to investigate the relationships between the primordial specific activities and the geological features of the soil samples collected and the geographic information system, ArcGIS v10.1 used to graphically depict the gamma profile of the primordials across the island. The Kruskal-Wallis test indicated that in general the variations of the primordial gamma specific activities over the underlying soil geologies were statistically significant. However, the pairwise Post-Hoc test results did not suggest a significant variation in mean specific for any of the primordial with all the underlying geology even when the unadjusted p value was used. This result along with the Spearman's coefficient correlation values suggested a moderate to weak relationship between the gamma profile of the top soil and its underlying geology. With the exception of a weak correlation with 232 Th (-0.295) no other primordial radionuclide correlated with the UNESCO/FAO soil categories for the island. The most significant correlations for soil characteristics and gamma activities were organic matters which were positive for 232 Th (0.518), 238 U (0.481) but negative for 40 K (-0.284). (author)

  8. Production of high-specific activity radionuclides using SM high-flux reactor

    International Nuclear Information System (INIS)

    Karelin, Ye.A.; Toporov, Yu.G.; Filimonov, V.T.; Vakhetov, F.Z.; Tarasov, V.A.; Kuznetsov, R.A.; Lebedev, V.M.; Andreev, O.I.; Melnik, M.I.; Gavrilov, V.D.

    1997-01-01

    The development of High Specific Activity (HSA) radionuclides production technologies is one of the directions of RIAR activity, and the high flux research reactor SM, having neutron flux density up to 2.10 15 cm -2 s 1 in a wide range of neutron spectra hardness, plays the principal role in this development. The use of a high-flux reactor for radionuclide production provides the following advantages: production of radionuclides with extremely high specific activity, decreasing of impurities content in irradiated targets (both radioactive and non-radioactive), cost-effective use of expensive isotopically enriched target materials. The production technologies of P-33, Gd-153, W-188, Ni-63, Fe-55,59, Sn-113,117m,119m, Sr- 89, applied in industry, nuclear medicine, research, etc, were developed by RIAR during the last 5-10 years. The research work included the development of calculation procedures for radionuclide reactor accumulation forecast, experimental determination of neutron cross-sections, the development of irradiated materials reprocessing procedures, isolation and purification of radionuclides. The principal results are reviewed in the paper. (authors)

  9. Fractionation of gamma-emitting fission products absorbed by red kidney beans (Phaseolus vulgaris L.)

    International Nuclear Information System (INIS)

    D'Souza, T.J.; Mistry, K.B.

    1980-01-01

    The gamma-emitting fission product nuclides 106 Ru, 125 Sb, 137 Cs and 144 Ce that accumulated in the edible pods of bean (Phaseolus vulgaris L.) plants grown in nutrient culture were subjected to chemical fractionation. The results indicated that the largest fraction of 106 Ru, 125 Sb and 144 Ce was associated with ionic forms including salts of organic acids, phosphates, carbonates and some protein-bound forms extracted with dilute mineral acids (acid fraction). The association of these radionuclides with lipids including lipophyllic pigments, free amino acids and amino sugars (ethanol fraction) was next in significance. The association of 137 Cs was, however, greater with the ethanol fraction than with the acid fraction. Considerably reduced amounts of the fission products were present in the pectates, proteins, polysaccharides and nucleic acids. (U.K.)

  10. Production of high specific activity silicon-32

    International Nuclear Information System (INIS)

    Phillips, D.R.; Brzezinski, M.A.

    1998-01-01

    This is the final report of a three-year, Laboratory Directed Research and Development Project (LDRD) at Los Alamos National Laboratory (LANL). There were two primary objectives for the work performed under this project. The first was to take advantage of capabilities and facilities at Los Alamos to produce the radionuclide 32 Si in unusually high specific activity. The second was to combine the radioanalytical expertise at Los Alamos with the expertise at the University of California to develop methods for the application of 32 Si in biological oceanographic research related to global climate modeling. The first objective was met by developing targetry for proton spallation production of 32 Si in KCl targets and chemistry for its recovery in very high specific activity. The second objective was met by developing a validated field-useable, radioanalytical technique, based upon gas-flow proportional counting, to measure the dynamics of silicon uptake by naturally occurring diatoms

  11. High-sensitivity gamma spectroscopy for extended sources. Application to activity measurements on the human body, on glass, and on soil; Spectrographie gamma a grande sensibilite pour sources etendues. Application a la mesure de l'activite du corps humain, du verre et du sol

    Energy Technology Data Exchange (ETDEWEB)

    Jouve, B

    1962-07-01

    The measurement and location by gamma spectroscopy of human body internal contaminations at maximum permissible levels, and, in certain cases, at lower activities such as that due to {sup 40}K was investigated. The characteristics of the high-sensitivity apparatus used are given, and several assemblies using large-volume NaI(Tl) scintillators are described. The relatively light shielding required for natural radioactivity permitted construction of mobile assembly. Conditions of use are described, and the results are given. All gamma emitting elements were measured in 15 min at levels lower than the tolerance dose. Gamma spectroscopy was also used to determine fission products in the earth and to study radioactive elements in the presence of other emitters. (author) [French] La spectrographie gamma du corps humain permet la mesure et la localisation des contaminations internes au niveau des doses de tolerance et, dans certains cas, celle d'activites plus faibles comme la radioactivite naturelle due principalement au potassium 40. Les caracteristiques des appareils a grande sensibilite permettant ces mesures sont exposees et on decrit plusieurs realisations originales utilisant un scintillateur NaI(Tl) de grand volume. L'epaisseur du blindage a ete limitee a 5 cm de plomb, ainsi, pour une protection suffisante contre les rayonnements ambiants, les appareils sont relativement legers et l'une des realisations a pu etre installee dans un laboratoire mobile. Les conditions d'utilisation (mouvement propre, etalonnage) et les resultats obtenus sont donnes; tous les radioelements emetteurs gamma sont mesurables en 15 minutes a un niveau inferieur a la dose de tolerance. On presente enfin des applications a la spectrographie gamma d'echantillons volumineux (poudres ou liquides) et de tres faible activite: elles interessent des domaines tres varies comme, par exemple, la geophysique (etude des retombees radioactives) ou l'industrie chimique

  12. Detection of gamma rays using scintillation optical fibers

    International Nuclear Information System (INIS)

    Park, J. W.; Hong, S. B.

    2002-01-01

    Scintillating optical fibers have several advantages over other conventional materials used for radiation detection. We have used glass and plastic scintillating fibers to detect gamma rays emitted from 60 Co and 137 Cs, and beta rays from 90 Sr. The sensors are constructed of single strand or multi-strand fibers of 1 mm diameter. The glass scintillating fiber used contains cerium-activated lithium-silicate as scintillating material and the plastic scintillating fiber used is Bicron model BCF-12. In this paper, we report the pulse-height spectra obtained by both sensor types, and analyze them in the aspect of their usability for radiation detectors. Our investigation suggests that the glass fiber can be used to develop gamma ray detectors which will function in high and low gamma ray flux environments. Use of the sensor for the beta ray detection was not satisfactory. The plastic fiber sensor did not work satisfactorily for the weak gamma sources, but did produce somewhat promising results. The scintillating plastic fiber offers some feasibility as beta ray sensor material

  13. Pedunculopontine Nucleus Gamma Band Activity-Preconscious Awareness, Waking, and REM Sleep

    Directory of Open Access Journals (Sweden)

    Francisco J Urbano

    2014-10-01

    Full Text Available The pedunculopontine nucleus (PPN is a major component of the reticular activating system (RAS that regulates waking and REM sleep, states of high frequency EEG activity. Recently, we described the presence of high threshold, voltage-dependent N- and P/Q-type calcium channels in RAS nuclei that subserve gamma band oscillations in the mesopontine pedunculopontine nucleus (PPN, intralaminar parafascicular nucleus (Pf, and pontine Subcoeruleus nucleus dorsalis (SubCD. Cortical gamma band activity participates in sensory perception, problem solving, and memory. Rather than participating in the temporal binding of sensory events as in the cortex, gamma band activity in the RAS may participate in the processes of preconscious awareness, and provide the essential stream of information for the formulation of many of our actions. That is, the RAS may play an early permissive role in volition. Our latest results suggest that, 1 the manifestation of gamma band activity during waking may employ a separate intracellular pathway compared to that during REM sleep, 2 neuronal calcium sensor (NCS-1 protein, which is over expressed in schizophrenia and bipolar disorder, modulates gamma band oscillations in the PPN in a concentration-dependent manner, 3 leptin, which undergoes resistance in obesity resulting in sleep dysregulation, decreases sodium currents in PPN neurons, accounting for its normal attenuation of waking, and 4 following our discovery of electrical coupling in the RAS, we hypothesize that there are cell clusters within the PPN that may act in concert. These results provide novel information on the mechanisms controlling high frequency activity related to waking and REM sleep by elements of the RAS.

  14. The sensitivity of gamma-index method to the positioning errors of high-definition MLC in patient-specific VMAT QA for SBRT

    International Nuclear Information System (INIS)

    Kim, Jung-in; Park, So-Yeon; Kim, Hak Jae; Kim, Jin Ho; Ye, Sung-Joon; Park, Jong Min

    2014-01-01

    To investigate the sensitivity of various gamma criteria used in the gamma-index method for patient-specific volumetric modulated arc therapy (VMAT) quality assurance (QA) for stereotactic body radiation therapy (SBRT) using a flattening filter free (FFF) photon beam. Three types of intentional misalignments were introduced to original high-definition multi-leaf collimator (HD-MLC) plans. The first type, referred to Class Out, involved the opening of each bank of leaves. The second type, Class In, involved the closing of each bank of leaves. The third type, Class Shift, involved the shifting of each bank of leaves towards the ground. Patient-specific QAs for the original and the modified plans were performed with MapCHECK2 and EBT2 films. The sensitivity of the gamma-index method using criteria of 1%/1 mm, 1.5%/1.5 mm, 1%/2 mm, 2%/1 mm and 2%/2 mm was investigated with absolute passing rates according to the magnitudes of MLCs misalignments. In addition, the changes in dose-volumetric indicators due to the magnitudes of MLC misalignments were investigated. The correlations between passing rates and the changes in dose-volumetric indicators were also investigated using Spearman’s rank correlation coefficient (γ). The criterion of 2%/1 mm was able to detect Class Out and Class In MLC misalignments of 0.5 mm and Class Shift misalignments of 1 mm. The widely adopted clinical criterion of 2%/2 mm was not able to detect 0.5 mm MLC errors of the Class Out or Class In types, and also unable to detect 3 mm Class Shift errors. No correlations were observed between dose-volumetric changes and gamma passing rates (γ < 0.8). Gamma criterion of 2%/1 mm was found to be suitable as a tolerance level with passing rates of 90% and 80% for patient-specific VMAT QA for SBRT when using MapCHECK2 and EBT2 film, respectively

  15. Controls of internal contamination from gamma-emitting radionuclides performed whole-body counter measures on children's population from Bjelorussia, Russia and Ucraina

    International Nuclear Information System (INIS)

    Tarroni, G.; Battisti, P.; Castellani, C.M.; Formignani, M.; Rampa, E.; Ticconi, R.

    1994-12-01

    This report summarizes the results obtained in 9 measurement campaigns, performed at the ENEA (Italian Agency for New Technologies, Energy and the Environment) centres of Bologna and Roma-Casaccia from April 1991 to September 1992, for the assessment of internal contamination from gamma-emitting radionuclides. Homogeneous samples were selected for the controls, each one representing the children's population from given area. 15 areas were investigated and 24 examined; 20 of them were from Bjelorussia. 266 children, 124 male and 142 female subjects, were controlled. The instruments were intercalibrated according to the body size, from 20.25 kg to 81 kg. Body contamination only from 1 37 Cs and 1 34 Cs was detected. Evaluations were performed in order to test appropriate use of ICRP caesium biokynetic model for children aged 8 to 15 years. Statistical distribution of body activity data were carefully analyzed. It is demonstrated that the data are well fitted by lognormal distribution and a difference between sexes in terms of activity. A significant difference between sexes was found in terms of activity intake

  16. Rapid and low-invasive functional brain mapping by realtime visualization of high gamma activity for awake craniotomy.

    Science.gov (United States)

    Kamada, K; Ogawa, H; Kapeller, C; Prueckl, R; Guger, C

    2014-01-01

    For neurosurgery with an awake craniotomy, the critical issue is to set aside enough time to identify eloquent cortices by electrocortical stimulation (ECS). High gamma activity (HGA) ranging between 80 and 120 Hz on electrocorticogram (ECoG) is assumed to reflect localized cortical processing. In this report, we used realtime HGA mapping and functional magnetic resonance imaging (fMRI) for rapid and reliable identification of motor and language functions. Three patients with intra-axial tumors in their dominant hemisphere underwent preoperative fMRI and lesion resection with an awake craniotomy. All patients showed significant fMRI activation evoked by motor and language tasks. After the craniotomy, we recorded ECoG activity by placing subdural grids directly on the exposed brain surface. Each patient performed motor and language tasks and demonstrated realtime HGA dynamics in hand motor areas and parts of the inferior frontal gyrus. Sensitivity and specificity of HGA mapping were 100% compared to ECS mapping in the frontal lobe, which suggested HGA mapping precisely indicated eloquent cortices. The investigation times of HGA mapping was significantly shorter than that of ECS mapping. Specificities of the motor and language-fMRI, however, did not reach 85%. The results of HGA mapping was mostly consistent with those of ECS mapping, although fMRI tended to overestimate functional areas. This novel technique enables rapid and accurate functional mapping.

  17. Characterizing gamma fields using isomeric activation ratios

    Science.gov (United States)

    Venkataraman, Ramkumar; Fleming, Ronald F.

    1994-12-01

    Isomeric activities were induced in indium by gamma irradiation in three different gamma fields, through the reactions 115In(γ, γ') 115mIn and 113In(γ, γ') 113mIn. The irradiation fields were (i) the 15 kCi 60Co source available in the University, (ii) the spent fuel gamma irradiator in the pool of the University's Ford Nuclear Reactor (FNR) and (iii) south face of the core of the FNR during routine shut downs. Isomeric activation ratios can serve to characterize gamma fields, provided the response functions of the two (γ, γ') reactions sample different energy regimes of the gamma spectrum present in the irradiation fields. The response of an isomeric activation detector, in turn, depends on the number of activation energy levels of the nuclide and the probabilities with which the activation levels de-populate to the isomeric level. The reaction rate ratio RIn115m/ RIn113m was measured in the three gamma fields. The measured ratios were (i) 1.210 ± 0.011 in the 60Co source, (ii) 1.314 ± 0.060 in the spent fuel gamma irradiator and (iii) 1.298 ± 0.039 in a location alongside the FNR core during routine shut downs. The measured reaction rate ratios are not only close to each other, but close to unity as well. This indicates that the excitation functions for the reactions 115In(γ, γ') 115mIn and 113In(γ, γ') 113mIn have similar shapes and that for the nuclides 115In and 113In, the number of activation energy levels and the probabilities with which they populate the isomeric levels are very similar to each other. Thus, the ratio RIn115m/ RIn113m will not yield any information regarding the shape of gamma spectrum in the field of measurement. However by choosing (γ, γ') reactions with different shapes for the excitation functions one can measure a set of isomeric activation ratios that characterize a given gamma field.

  18. A cannonball model of gamma-ray bursts superluminal signatures

    CERN Document Server

    Dar, Arnon; Dar, Arnon; Rujula, Alvaro De

    2000-01-01

    Recent observations suggest that the long-duration gamma ray bursts (GRBs) and their afterglows are produced by highly relativistic jets emitted in supernova explosions. We propose that the result of the event is not just a compact object plus the ejecta: within a day, a fraction of the parent star falls back to produce a thick accretion disk. The subsequent accretion generates jets and constitutes the GRB ``engine'', as in the observed ejection of relativistic ``cannonballs'' of plasma by microquasars and active galactic nuclei. The GRB is produced as the jetted cannonballs exit the supernova shell reheated by the collision, re-emitting their own radiation and boosting the light of the shell. They decelerate by sweeping up interstellar matter, which is accelerated to cosmic-ray energies and emits synchrotron radiation: the afterglow. We emphasize here a smoking-gun signature of this model of GRBs: the superluminal motion of the afterglow, that can be searched for ---the sooner the better--- in the particular...

  19. Highly efficient white top-emitting organic light-emitting diodes with forward directed light emission

    Energy Technology Data Exchange (ETDEWEB)

    Freitag, Patricia; Reineke, Sebastian; Furno, Mauro; Luessem, Bjoern; Leo, Karl [Institut fuer Angewandte Photophysik, TU Dresden (Germany)

    2010-07-01

    The demand for highly efficient and energy saving illumination has increased considerably during the last decades. Organic light emitting diodes (OLEDs) are promising candidates for future lighting technologies. They offer high efficiency along with excellent color quality, allowing substantially lower power consumption than traditional illuminants. Recently, especially top-emitting devices have attracted high interest due to their compatibility with opaque substrates like metal sheets. In this contribution, we demonstrate top-emitting OLEDs with white emission spectra employing a multilayer hybrid cavity structure with two highly efficient phosphorescent emitter materials for orange-red (Ir(MDQ)2(acac)) and green (Ir(ppy)3) emission as well as the stable fluorescent blue emitter TBPe. To improve the OLED performance and modify the color quality, two different electron blocking layers and anode material combinations are tested. Compared to Lambertian emission, our devices show considerably enhanced forward emission, which is preferred for most lighting applications. Besides broadband emission and angle independent emission maxima, power efficiencies of 13.3 lm/W at 3 V and external quantum efficiencies of 5.3% are achieved. The emission shows excellent CIE coordinates of (0.420,0.407) at approx. 1000 cd/m{sup 2} and color rendering indices up to 77.

  20. Active targeting of tumor cells using light emitting bacteria

    International Nuclear Information System (INIS)

    Moon, Sung Min; Min, Jung Joon; Hong, Yeong Jin; Kim, Hyun Ju; Le, Uuenchi N.; Rhee, Joon Haeng; Song, Ho Chun; Heo, Young Jun; Bom, Hee Seung; Choy, Hyon E

    2004-01-01

    The presence of bacteria and viruses in human tumors has been recognized for more than 50 years. Today, with the discovery of bacterial strains that specifically target tumors, and aided by genomic sequencing and genetic engineering, there is new interest in the use of bacteria as tumor vectors. Here, we show that bacteria injected intravenously into live animals entered and replicated in solid tumors and metastases using the novel imaging technology of biophotonics. Bioluminescence operon (LuxCDABE) or fluorescence protein, GFP) has been cloned into pUC19 plasmid to engineer pUC19lux or pUC19gfp. Engineered plasmid was transformed into different kinds of wild type (MG1655) or mutant E. coli (DH5, ppGpp, fnr, purE, crpA, flagella, etc.) strains to construct light emitting bacteria. Xenograft tumor model has been established using CT26 colon cancer cell line. Light emitting bacteria was injected via tail vein into tumor bearing mouse. In vivo bioluminescence imaging has been done after 20 min to 14 days of bacterial injection. We observed localization of tumors by light-emitting E. coli in tumor (CT-26) bearing mice. We confirmed the presence of light-emitting bacteria under the fluorescence microscope with E. coli expressing GFP. Althoug varying mutants strain with deficient invading function has been found in tumor tissues, mutant strains of movement (flagella) couldn't show any light signal from the tumor tissue under the cooled CCD camera, indicating bacteria may actively target the tumor cells. Based on their 'tumor-finding' nature, bacteria may be designed to carry multiple genes or drugs for detection and treatment of cancer, such as prodrug-converting enzymes, toxins, angiogenesis inhibitors and cytokines

  1. SWEPP gamma-ray spectrometer system software user's guide

    International Nuclear Information System (INIS)

    Femec, D.A.

    1994-08-01

    The SWEPP Gamma-Ray Spectrometer (SGRS) System has been developed by the Radiation Measurement and Development Unit of the Idaho National Engineering Laboratory to assist in the characterization of the radiological contents of contact-handled waste containers at the Stored Waste Examination Pilot Plant (SWEPP). In addition to determining the concentrations of gamma-ray-emitting radionuclides, the software also calculates attenuation-corrected isotopic mass ratios of specific interest, and provides controls for SGRS hardware as required. This document serves as a user's guide for the data acquisition and analysis software associated with the SGRS system

  2. High energy astrophysics with ground-based gamma ray detectors

    International Nuclear Information System (INIS)

    Aharonian, F; Buckley, J; Kifune, T; Sinnis, G

    2008-01-01

    Recent advances in ground-based gamma ray astronomy have led to the discovery of more than 70 sources of very high energy (E γ ≥ 100 GeV) gamma rays, falling into a number of source populations including pulsar wind nebulae, shell type supernova remnants, Wolf-Rayet stars, giant molecular clouds, binary systems, the Galactic Center, active galactic nuclei and 'dark' (yet unidentified) galactic objects. We summarize the history of TeV gamma ray astronomy up to the current status of the field including a description of experimental techniques and highlight recent astrophysical results. We also discuss the potential of ground-based gamma ray astronomy for future discoveries and describe possible directions for future instrumental developments

  3. The metrological activity determination of 238 U and 230 Th by gamma spectrometry to industrial fuel-cycle application

    International Nuclear Information System (INIS)

    Almeida M, M.C. de; Delgado, J.U.; Poledna, R.

    2006-01-01

    This work describes the difficulty for determining the activity of 238 U and 230 Th using gamma spectrometry due to the low gamma-ray emission probabilities of 92 and 67 keV, and, mainly, the associated high uncertainties about 13 and 11%, respectively. 230 Th is a 238 U daughter and it is product from uranium mills and refineries. 230 Th decays to 226 Ra and this decay has to be measured because these radionuclides are not in secular equilibrium with their daughter products, besides the gamma-energies have high uncertainties in the emission probabilities. These radionuclides, mostly 238 U, are important in the nuclear fuel-cycle, since the mining of uranium ore, where the nominal isotopic content of natural uranium is 99.27% of 238 U, until the irradiated fuel reprocessing, where this isotope, a fertile material, is recovered to be used again. The uranium and thorium are considered safeguarded nuclear materials and the metrology tries to calibrate and standardize these materials to improve the activity determination techniques applied in different fuel-cycle scopes. The essential characteristics of the safeguarded materials are low gamma energies (less than 100 keV) and emission probabilities but with high uncertainties. In this way, the metrology can contribute to homeland security defense against illicit nuclear trafficking with the identification and quantification of the safeguarded radionuclides such as uranium and thorium, using specific gamma window energy and high resolution planar or coaxial germanium detector. The efficiency curve is obtained from the reference source spectrum considering the photopeak areas corresponding the standard activities. This curve depends on radiation energy, sample geometry, photon attenuation (sample absorption and material absorption between sample-detector), dead time and sample-detector position. The metrological activity determinations of 238 U solid sources, and of 230 Th, in solution (5 ml flask), were performed using

  4. Open high-level data formats and software for gamma-ray astronomy

    Science.gov (United States)

    Deil, Christoph; Boisson, Catherine; Kosack, Karl; Perkins, Jeremy; King, Johannes; Eger, Peter; Mayer, Michael; Wood, Matthew; Zabalza, Victor; Knödlseder, Jürgen; Hassan, Tarek; Mohrmann, Lars; Ziegler, Alexander; Khelifi, Bruno; Dorner, Daniela; Maier, Gernot; Pedaletti, Giovanna; Rosado, Jaime; Contreras, José Luis; Lefaucheur, Julien; Brügge, Kai; Servillat, Mathieu; Terrier, Régis; Walter, Roland; Lombardi, Saverio

    2017-01-01

    In gamma-ray astronomy, a variety of data formats and proprietary software have been traditionally used, often developed for one specific mission or experiment. Especially for ground-based imaging atmospheric Cherenkov telescopes (IACTs), data and software are mostly private to the collaborations operating the telescopes. However, there is a general movement in science towards the use of open data and software. In addition, the next-generation IACT instrument, the Cherenkov Telescope Array (CTA), will be operated as an open observatory. We have created a Github organisation at https://github.com/open-gamma-ray-astro where we are developing high-level data format specifications. A public mailing list was set up at https://lists.nasa.gov/mailman/listinfo/open-gamma-ray-astro and a first face-to-face meeting on the IACT high-level data model and formats took place in April 2016 in Meudon (France). This open multi-mission effort will help to accelerate the development of open data formats and open-source software for gamma-ray astronomy, leading to synergies in the development of analysis codes and eventually better scientific results (reproducible, multi-mission). This write-up presents this effort for the first time, explaining the motivation and context, the available resources and process we use, as well as the status and planned next steps for the data format specifications. We hope that it will stimulate feedback and future contributions from the gamma-ray astronomy community.

  5. The activity of {gamma}-emitters as measured by ionisation chambers the determination of the specific emission coefficient {gamma} for some radio-elements (1961); Mesure de l'activite des emetteurs {gamma} par chambre d'ionisation. Determination du coefficient specifique d'emission {gamma} de quelques radioelements (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Engelmann, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-06-15

    The object of this work is to study techniques of measurement using the gamma ionisation chamber, making it possible either to measure the activities of radioactive sources, or to determine the specific emission coefficient {gamma} (or the coefficient K) of a given radioelement. The ionisation chambers studied belong to two categories: graphites cavity-chambers, and 4 {pi} {gamma} chambers. For the cavity-chamber measurements, the different correction factors of which account must be taken have been calculated, in particular the geometric and hygrometric corrections. The absorption and auto-absorption corrections have led to the introduction of the notion of the 'effective energy {gamma}' of a radioelement. In the case of 4 {pi} {gamma} chambers, it has been shown that appropriately shaped electrodes make it possible to improve their performances. One of the chambers described permits the measurement of {beta} emitters using the associated Bremsstrahlung. In order to measure the K coefficient of some radioelements, it has been found useful a 4 {pi} {gamma} chamber with graphite walls, the measurement being carried out by comparison with a radium standard. The validity of the method was checked with radioelements for whom the K coefficient values are well-known ({sup 24}Na, {sup 60}Co, {sup 131}I, {sup 198}Au). For other radioelements, the following values were obtained (expressed in r cm{sup 3} mc{sup -1} h{sup -1}): {sup 51}Cr: 0,18; {sup 56}Mn: 8,8; {sup 65}Zn: 3,05; {sup 124}Sb: 9,9; {sup 134}Cs: 9,3; {sup 137}Cs: 3,35; {sup 141}Ce: 0,46; {sup 170}Tm: 0,023; {sup 192}Ir: 24,9; {sup 203}Hg: 1,18; These values have been corrected for the contribution to the dose of the fluorescent radiation which may be emitted by the source, except in the case of Tm{sup 170}. In the last part of this work, the performances of the different electro-metric devices used were compared. (author) [French] Le but de ce travail est d'etudier les techniques de mesure par chambre d

  6. Prompt Gamma Ray Spectroscopy for process monitoring

    International Nuclear Information System (INIS)

    Zoller, W.H.; Holmes, J.L.

    1991-01-01

    Prompt Gamma Ray Spectroscopy (PGRS) is a very powerful analytical technique able to measure many metallic, contamination problem elements. The technique involves measurement of gamma rays that are emitted by nuclei upon capturing a neutron. This method is sensitive not only to the target element but also to the particular isotope of that element. PGRS is capable of measuring dissolved metal ions in a flowing system. In the field, isotopic neutron sources are used to produce the desired neutron flux ( 252 Cf can produce neutron flux of the order of 10 8 neutrons/cm 2 --sec.). Due to high penetrating power of gamma radiation, high efficiency gamma ray detectors can be placed in an appropriate geometry to maximize sensitivity, providing real-time monitoring with low detection level capabilities

  7. Sediment studies at Bikini Atoll part 3. Inventories of some long-lived gamma-emitting radionuclides associated with lagoon surface sediments

    Energy Technology Data Exchange (ETDEWEB)

    Noshkin, V.E.

    1997-12-01

    Surface sediment samples were collected during 1979 from 87 locations in the lagoon at Bikini Atoll. The collections were made to better define the concentrations and distribution of long-lived radionuclides associated with the bottom material and to show what modifications occurred to the composition of the surface sediment from the nuclear testing program conducted by the United States at the Atoll between 1946 and 1958. This is the last of three reports on Bikini sediment studies. In this report, we discuss the concentrations and inventories of the residual long-lived gamma-emitting radionuclides in sediments from the lagoon. The gamma-emitting radionuclides detected most frequently in sediments collected in 1979, in addition to Americium-241 ({sup 241}Am) (discussed in the second report of this series), included Cesium-137 ({sup 137}Cs), Bismuth-207 ({sup 207}Bi), Europium-155 ({sup 155}Eu), and Cobalt-60 ({sup 60}Co). Other man-made, gamma-emitting radionuclides such as Europium-152,154 ({sup 152,154}Eu), Antimony-125 ({sup 125}Sb), and Rhodium-101,102m ({sup 101,102m}Rh) were occasionally measured above detection limits in sediments near test site locations. The mean inventories for {sup 137}Cs, {sup 207}Ei, {sup 155}Eu, and {sup 60}Co in the surface 4 cm of the lagoon sediment to be 1.7, 0.56, 7.76, and 0.74 TBq, respectively. By June 1997, radioactive decay would reduce these values to 1.1, 0.38, 0.62, and 0.07 TBq, respectively. Some additional loss results from a combination of different processes that continuously mobilize and return some amount of the radionuclides to the water column. The water and dissolved constituents are removed from the lagoon through channels and exchange with the surface waters of the north equatorial Pacific Ocean. Highest levels of these radionuclides are found in surface deposits lagoonward of the Bravo Crater. Lowest concentrations and inventories are associated with sediment lagoonward of the eastern reef. The quantities in

  8. SPEAR-FCODE-GAMMA functional specifications. Final report

    International Nuclear Information System (INIS)

    Fiero, I.B.

    1983-03-01

    SPEAR FCODE GAMMA (SFG), a conceptual fuel-performance code for use in licensing analyses, has been defined and characterized as a set of functional specifications. The potential licensing-related applications of SFG are established and discussed. General code specifications including regulatory, interface, hardware application, code model and software, and operational specifications are discussed. The code input and output information including data requirements as well as formatting aspects are detailed. Finally, the SFG code-accuracy guidelines are established and the validation process is described

  9. N-tritioacetoxyphthalimide: A new high specific activity tritioacetylating reagent

    International Nuclear Information System (INIS)

    Saljoughian, M.; Morimoto, Hiromi; Than, Chit

    1996-01-01

    The authors' aim was to develop a nonvolatile, stable, and facile tritioacetylating reagent and to demonstrate its use on simple peptides. Accordingly, the authors made the synthesis of high specific activity N-(tritioacetoxy) derivatives of succinimide, phthalimide, and naphthalimide a major focus. As the preferred approach, N-(tritioacetoxy)phthalimide was prepared by radical dehalogenation of N-(iodoacetoxy)phthalimide using high specific activity tributyltin tritide. This tritiated acetylation reagent was characterized by 3 H and 1 H NMR spectroscopy and by radio-HPLC. Efficacy of the reagent was investigated by tritioacetylation of several peptides at their N-terminal amino group. 26 refs., 1 fig

  10. Preliminary results on soil-emitted gamma radiation and its relation with the local atmospheric electric field at Amieira (Portugal)

    International Nuclear Information System (INIS)

    Lopes, F; Barbosa, S M; Silva, H G; Bárias, S

    2015-01-01

    The atmospheric electric field near the Earth's surface is dominated by atmospheric pollutants and natural radioactivity, with the latter directly linked to radon ( 222 Rn) gas. For a better comprehension on the temporal variability of both the atmospheric electric field and the radon concentration and its relation with local atmospheric variables, simultaneous measurements of soil-emitted gamma radiation and potential gradient (defined from the vertical component of the atmospheric electric field) were taken every minute, along with local meteorological parameters (e.g., temperature, atmospheric pressure, relative humidity and daily solar radiation). The study region is Amieira, part of the Alqueva lake in Alentejo Portugal, where an interdisciplinary meteorological campaign, ALEX2014, took place from June to August 2014. Soil gamma radiation is more sensitive to small concentrations of radon as compared with alpha particles measurements, for that reason it is more suited for sites with low radon levels, as expected in this case. Preliminary results are presented here: statistical and spectral analysis show that i) the potential gradient has a stronger daily cycle as compared with the gamma radiation, ii) most of the energy of the gamma signal is concentrated in the low frequencies (close to 0), contrary to the potential gradient that has most of the energy in frequency 1 (daily cycle) and iii) a short-term relation between gamma radiation and the potential gradient has not been found. Future work and plans are also discussed. (paper)

  11. Summary report of consultants' meeting on high-precision beta-intensity measurements and evaluations for specific PET radioisotopes

    International Nuclear Information System (INIS)

    Capote Noy, R.; Nicols, A.L.

    2009-12-01

    A summary is given of a Consultants' Meeting on 'High-precision beta-intensity measurements and evaluations for specific PET radioisotopes'. Participants assessed and reviewed the decay data for close to 50 positron-emitting radionuclides. Technical discussions are described in this report, along with the detailed recommendations and a priority list for future work. Direct positron and X-ray measurements are required to resolve a significant number of outstanding issues associated with the radionuclides reviewed. The following new measurements are recommended: gamma-ray emission probability for Cu-64, positron and Xray emission probabilities for Ni-57, Cu-62, Ga-66, As-72, Se-73, Rb-81,82m, Sr-83, Y-86 and Tc-94m. The following immediate evaluations were also recommended: Br-76 and I-120g.. Participants assessed and reviewed the decay data for close to 50 positron-emitting radionuclides. Technical discussions are described in this report, along with the detailed recommendations and a priority list for future work. Direct positron and X-ray measurements are required to resolve a significant number of outstanding issues associated with the radionuclides reviewed. The following new measurements are recommended: gamma-ray emission probability for Cu-64, positron and Xray emission probabilities for Ni-57, Cu-62, Ga-66, As-72, Se-73, Rb-81,82m, Sr-83, Y-86 and Tc-94m. The following immediate evaluations were also recommended: Br-76 and I-120g. (author)

  12. Gamma-ray pulsars: Emission zones and viewing geometries

    Science.gov (United States)

    Romani, Roger W.; Yadigaroglu, I.-A.

    1995-01-01

    There are now a half-dozen young pulsars detected in high-energy photons by the Compton Gamma-Ray Observatory (CGRO), showing a variety of emission efficiencies and pulse profiles. We present here a calculation of the pattern of high-energy emission on the sky in a model which posits gamma-ray production by charge-depleted gaps in the outer magnetosphere. This model accounts for the radio to gamma-ray pulse offsets of the known pulsars, as well as the shape of the high-energy pulse profiles. We also show that about one-third of emitting young radio pulsars will not be detected due to beaming effects, while approximately 2.5 times the number of radio-selected gamma-ray pulsars will be viewed only high energies. Finally we compute the polarization angle variation and find that the previously misunderstood optical polarization sweep of the Crab pulsar arises naturally in this picture. These results strongly support an outer magnetosphere location for the gamma-ray emission.

  13. Effect of gamma irradiation on fluoride release and antibacterial activity of resin dental materials

    International Nuclear Information System (INIS)

    Carvalho, Fabiola Galbiatti de; Fucio, Suzana Beatriz Portugal de; Correr-Sobrinho, Lourenco; Pascon, Fernanda Miori; Kantovitz, Kamila Rosamilia; Puppin-Rontani, Regina Maria

    2009-01-01

    This study evaluated the effect of gamma irradiation on fluoride release and antibacterial activity of FluroShield (FS) and Clearfil Protect Bond (CPB). Four groups were formed: G1-FS + gamma; G2-FS without gamma; G3-CPB + gamma; G4-CPB without gamma. For fluoride release analysis, 12 disks of each material were prepared and covered with nail polish, except for one side (50.4 mm 2 area). G1 and G3 were sterilized with a 14.5 KGy dose at 27 deg C for 24 h, while G2 and G4 (controls) were not sterilized and were maintained under the same time and temperature conditions. Fluoride release measurements were made in duplicate (n=6) by an ion specific electrode. The antibacterial activity of the CPB and FS against Streptococcus mutans after gamma sterilization was evaluated by the agar-disc diffusion method. The diameter of the zones of microbial growth inhibition was recorded after 48 h. Data were analyzed statistically by ANOVA and Tukey's test (alpha=5%). Gamma sterilization decreased the fluoride release of FS by approximately 50%, while CPB was not affected. There was no statistically significant difference (p>0.05) in the antibacterial effect of CPB between gamma and non-gamma sterilization groups. FS presented no antibacterial activity. Gamma irradiation decreased the fluoride release of FS, but did not affect the antibacterial activity of the studied materials. (author)

  14. Effect of gamma irradiation on fluoride release and antibacterial activity of resin dental materials

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Fabiola Galbiatti de; Fucio, Suzana Beatriz Portugal de; Correr-Sobrinho, Lourenco [Universidade Estadual de Campinas (UNICAMP), Piracicaba, SP (Brazil). Piracicaba Dental School. Dept. of Dental Materials; Pascon, Fernanda Miori; Kantovitz, Kamila Rosamilia; Puppin-Rontani, Regina Maria [Universidade Estadual de Campinas (UNICAMP), Piracicaba, SP (Brazil). Piracicaba Dental School. Dept. of Pedriatric Dentistry], e-mail: rmpuppin@fop.unicamp.br

    2009-07-01

    This study evaluated the effect of gamma irradiation on fluoride release and antibacterial activity of FluroShield (FS) and Clearfil Protect Bond (CPB). Four groups were formed: G1-FS + gamma; G2-FS without gamma; G3-CPB + gamma; G4-CPB without gamma. For fluoride release analysis, 12 disks of each material were prepared and covered with nail polish, except for one side (50.4 mm{sup 2} area). G1 and G3 were sterilized with a 14.5 KGy dose at 27 deg C for 24 h, while G2 and G4 (controls) were not sterilized and were maintained under the same time and temperature conditions. Fluoride release measurements were made in duplicate (n=6) by an ion specific electrode. The antibacterial activity of the CPB and FS against Streptococcus mutans after gamma sterilization was evaluated by the agar-disc diffusion method. The diameter of the zones of microbial growth inhibition was recorded after 48 h. Data were analyzed statistically by ANOVA and Tukey's test (alpha=5%). Gamma sterilization decreased the fluoride release of FS by approximately 50%, while CPB was not affected. There was no statistically significant difference (p>0.05) in the antibacterial effect of CPB between gamma and non-gamma sterilization groups. FS presented no antibacterial activity. Gamma irradiation decreased the fluoride release of FS, but did not affect the antibacterial activity of the studied materials. (author)

  15. Monte Carlo simulation of gamma-ray interactions in an over-square high-purity germanium detector for in-vivo measurements

    Science.gov (United States)

    Saizu, Mirela Angela

    2016-09-01

    The developments of high-purity germanium detectors match very well the requirements of the in-vivo human body measurements regarding the gamma energy ranges of the radionuclides intended to be measured, the shape of the extended radioactive sources, and the measurement geometries. The Whole Body Counter (WBC) from IFIN-HH is based on an “over-square” high-purity germanium detector (HPGe) to perform accurate measurements of the incorporated radionuclides emitting X and gamma rays in the energy range of 10 keV-1500 keV, under conditions of good shielding, suitable collimation, and calibration. As an alternative to the experimental efficiency calibration method consisting of using reference calibration sources with gamma energy lines that cover all the considered energy range, it is proposed to use the Monte Carlo method for the efficiency calibration of the WBC using the radiation transport code MCNP5. The HPGe detector was modelled and the gamma energy lines of 241Am, 57Co, 133Ba, 137Cs, 60Co, and 152Eu were simulated in order to obtain the virtual efficiency calibration curve of the WBC. The Monte Carlo method was validated by comparing the simulated results with the experimental measurements using point-like sources. For their optimum matching, the impact of the variation of the front dead layer thickness and of the detector photon absorbing layers materials on the HPGe detector efficiency was studied, and the detector’s model was refined. In order to perform the WBC efficiency calibration for realistic people monitoring, more numerical calculations were generated simulating extended sources of specific shape according to the standard man characteristics.

  16. Activation analysis for measurements of silicon, phosphorus, alkali metals and other elements in high-purity metals

    International Nuclear Information System (INIS)

    Schmid, W.

    1988-01-01

    In the present thesis, methods of activation analysis were developed for the determination of the elements silicon, phosphorus, potassium, sodium, i.a. in the high-purity metals vanadium, niobium, tantalum, tungsten, molybdenum and iron. The determination of silicon is based on the activation of samples with reactor neutrons, on a subsequent radiochemical separation of the tracer radionuclide 31 Si resulting from the reaction 30 Si(n,γ), and on the measurement of β activity with the help of a liquid scintillation measuring desk. Since the tracer radionuclide 31 Si almost exclusively emits β rays which are not sufficiently nuclide-specific, silicon was selectively separated from the other sample elements by being distilled as silicon tetrafluoride. The processing of the residue following the separation of silicon permits a complementary gamma-spectroscopic determination of a whole lot of additional elements. Thus, the separation of the nuclide 182 Ta with the anion exchanger Dowex 1X8 from HF/H 2 SO 4 medium permits the determination of 22 elements in vanadium, niobium and tantalum. Phosphorus content is determined by activating the samples with rapid neutrons (cyclotrons) via the reaction 31 P(n,p) 31 Si. (orig./MM) [de

  17. Influence of radiation-dose pattern from inhaled beta--gamma-emitting radionuclides on canine peripheral lymphocytes

    International Nuclear Information System (INIS)

    Jones, R.K.; Boecker, B.B.; Pickrell, J.A.; Hobbs, C.H.; McClellan, R.O.

    1976-01-01

    As part of studies assess the biological hazards associated with inhaled radionuclides, periodic hematologic evaluations were performed on beagle dogs given a single nose-only exposure to aerosols of beta--gamma-emitting isotopes. The physical form and specific radionuclides selected produced radiation-dose patterns representative of those which might be encountered in the event of human accidental exposures. Dogs received graded lung burdens of either 90 Y, 91 Y, 144 Ce, or 90 Sr, each in fused clay. Differences in the effective half-lives of these radionuclides resulted in a spectrum of cumulative radiation doses to lung delivered at a variety of dose rates. Since the form in which the radionuclides were inhaled was relatively insoluble, the lung and intrathoracic tissues represented the primary recipient of the dose. Regardless of the effective half-life of radionuclide retention, a dose-related depression of peripheral lymphocytes was observed at various times after inhalation exposure. The time at which maximum depression and subsequent recovery occurred, however, was most directly related to the effective half-life of the radionuclide. Of special interest was the persistence of lymphopenia through 2 1 / 2 years after exposure to 144 Ce and 90 Sr in fused clay where, other than tracheobronchial lymph nodes, the lymphoid tissue received very little radiation dose. The possible mechanisms responsible for lymphocyte depression from these various radiation-dose patterns are discussed

  18. Submonolayer Quantum Dots for High Speed Surface Emitting Lasers

    Directory of Open Access Journals (Sweden)

    Zakharov ND

    2007-01-01

    Full Text Available AbstractWe report on progress in growth and applications of submonolayer (SML quantum dots (QDs in high-speed vertical-cavity surface-emitting lasers (VCSELs. SML deposition enables controlled formation of high density QD arrays with good size and shape uniformity. Further increase in excitonic absorption and gain is possible with vertical stacking of SML QDs using ultrathin spacer layers. Vertically correlated, tilted or anticorrelated arrangements of the SML islands are realized and allow QD strain and wavefunction engineering. Respectively, both TE and TM polarizations of the luminescence can be achieved in the edge-emission using the same constituting materials. SML QDs provide ultrahigh modal gain, reduced temperature depletion and gain saturation effects when used in active media in laser diodes. Temperature robustness up to 100 °C for 0.98 μm range vertical-cavity surface-emitting lasers (VCSELs is realized in the continuous wave regime. An open eye 20 Gb/s operation with bit error rates better than 10−12has been achieved in a temperature range 25–85 °Cwithout current adjustment. Relaxation oscillations up to ∼30 GHz have been realized indicating feasibility of 40 Gb/s signal transmission.

  19. A gamma-gamma coincidence/anticoincidence spectrometer for low-level cosmogenic (22)Na/(7)Be activity ratio measurement.

    Science.gov (United States)

    Zhang, Weihua; Ungar, Kurt; Stukel, Matthew; Mekarski, Pawel

    2014-04-01

    In this study, a digital gamma-gamma coincidence/anticoincidence spectrometer was developed and examined for low-level cosmogenic (22)Na and (7)Be in air-filter sample monitoring. The spectrometer consists of two bismuth germanate scintillators (BGO) and an XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The spectrometer design allows a more selective measurement of (22)Na with a significant background reduction by gamma-gamma coincidence events processing. Hence, the system provides a more sensitive way to quantify trace amounts of (22)Na than normal high resolution gamma spectrometry providing a critical limit of 3 mBq within a 20 h count. The use of a list-mode data acquisition technique enabled simultaneous determination of (22)Na and (7)Be activity concentrations using a single measurement by coincidence and anticoincidence mode respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Nearly Efficiency-Droop-Free AlGaN-Based Ultraviolet Light-Emitting Diodes with a Specifically Designed Superlattice p-Type Electron Blocking Layer for High Mg Doping Efficiency

    Science.gov (United States)

    Zhang, Zi-Hui; Huang Chen, Sung-Wen; Chu, Chunshuang; Tian, Kangkai; Fang, Mengqian; Zhang, Yonghui; Bi, Wengang; Kuo, Hao-Chung

    2018-04-01

    This work reports a nearly efficiency-droop-free AlGaN-based deep ultraviolet light-emitting diode (DUV LED) emitting in the peak wavelength of 270 nm. The DUV LED utilizes a specifically designed superlattice p-type electron blocking layer (p-EBL). The superlattice p-EBL enables a high hole concentration in the p-EBL which correspondingly increases the hole injection efficiency into the multiple quantum wells (MQWs). The enhanced hole concentration within the MQW region can more efficiently recombine with electrons in the way of favoring the radiative recombination, leading to a reduced electron leakage current level. As a result, the external quantum efficiency for the proposed DUV LED structure is increased by 100% and the nearly efficiency-droop-free DUV LED structure is obtained experimentally.

  1. High gamma power in ECoG reflects cortical electrical stimulation effects on unit activity in layers V/VI

    Science.gov (United States)

    Yazdan-Shahmorad, Azadeh; Kipke, Daryl R.; Lehmkuhle, Mark J.

    2013-12-01

    Objective. Cortical electrical stimulation (CES) has been used extensively in experimental neuroscience to modulate neuronal or behavioral activity, which has led this technique to be considered in neurorehabilitation. Because the cortex and the surrounding anatomy have irregular geometries as well as inhomogeneous and anisotropic electrical properties, the mechanism by which CES has therapeutic effects is poorly understood. Therapeutic effects of CES can be improved by optimizing the stimulation parameters based on the effects of various stimulation parameters on target brain regions. Approach. In this study we have compared the effects of CES pulse polarity, frequency, and amplitude on unit activity recorded from rat primary motor cortex with the effects on the corresponding local field potentials (LFP), and electrocorticograms (ECoG). CES was applied at the surface of the cortex and the unit activity and LFPs were recorded using a penetrating electrode array, which was implanted below the stimulation site. ECoGs were recorded from the vicinity of the stimulation site. Main results. Time-frequency analysis of LFPs following CES showed correlation of gamma frequencies with unit activity response in all layers. More importantly, high gamma power of ECoG signals only correlated with the unit activity in lower layers (V-VI) following CES. Time-frequency correlations, which were found between LFPs, ECoGs and unit activity, were frequency- and amplitude-dependent. Significance. The signature of the neural activity observed in LFP and ECoG signals provides a better understanding of the effects of stimulation on network activity, representative of large numbers of neurons responding to stimulation. These results demonstrate that the neurorehabilitation and neuroprosthetic applications of CES targeting layered cortex can be further improved by using field potential recordings as surrogates to unit activity aimed at optimizing stimulation efficacy. Likewise, the signatures

  2. EGRET upper limits to the high-energy gamma-ray emission from the millisecond pulsars in nearby globular clusters

    Science.gov (United States)

    Michelson, P. F.; Bertsch, D. L.; Brazier, K.; Chiang, J.; Dingus, B. L.; Fichtel, C. E.; Fierro, J.; Hartman, R. C.; Hunter, S. D.; Kanbach, G.

    1994-01-01

    We report upper limits to the high-energy gamma-ray emission from the millisecond pulsars (MSPs) in a number of globular clusters. The observations were done as part of an all-sky survey by the energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory (CGRO) during Phase I of the CGRO mission (1991 June to 1992 November). Several theoretical models suggest that MSPs may be sources of high-energy gamma radiation emitted either as primary radiation from the pulsar magnetosphere or as secondary radiation generated by conversion into photons of a substantial part of the relativistic e(+/-) pair wind expected to flow from the pulsar. To date, no high-energy emission has been detected from an individual MSP. However, a large number of MSPs are expected in globular cluster cores where the formation rate of accreting binary systems is high. Model predictions of the total number of pulsars range in the hundreds for some clusters. These expectations have been reinforced by recent discoveries of a substantial number of radio MSPs in several clusters; for example, 11 have been found in 47 Tucanae (Manchester et al.). The EGRET observations have been used to obtain upper limits for the efficiency eta of conversion of MSP spin-down power into hard gamma rays. The upper limits are also compared with the gamma-ray fluxes predicted from theoretical models of pulsar wind emission (Tavani). The EGRET limits put significant constraints on either the emission models or the number of pulsars in the globular clusters.

  3. Monte Carlo simulation of gamma-ray total counting efficiency for a Phoswich detector

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, S. [Education Faculty, Kastamonu University, 37200 Kastamonu (Turkey)], E-mail: syalcin@kastamonu.edu.tr; Gurler, O. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Gundogdu, O. [Department of Physics, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, GU2 7XH (United Kingdom); NCCPM, Medical Physics, Royal Surrey County Hospital, Guildford, GU2 7XX (United Kingdom); Kaynak, G. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey)

    2009-01-15

    The LB 1000-PW detector is mainly used for determining total alpha, beta and gamma activity of low activity natural sources such as water, soil, air filters and any other environmental sources. Detector efficiency needs to be known in order to measure the absolute activity of such samples. This paper presents results on the total gamma counting efficiency of a Phoswich detector from point and disk sources. The directions of photons emitted from the source were determined by Monte Carlo techniques and the true path lengths in the detector were determined by analytical equations depending on photon directions. Results are tabulated for various gamma energies.

  4. Monte Carlo simulation of gamma-ray total counting efficiency for a Phoswich detector

    International Nuclear Information System (INIS)

    Yalcin, S.; Gurler, O.; Gundogdu, O.; Kaynak, G.

    2009-01-01

    The LB 1000-PW detector is mainly used for determining total alpha, beta and gamma activity of low activity natural sources such as water, soil, air filters and any other environmental sources. Detector efficiency needs to be known in order to measure the absolute activity of such samples. This paper presents results on the total gamma counting efficiency of a Phoswich detector from point and disk sources. The directions of photons emitted from the source were determined by Monte Carlo techniques and the true path lengths in the detector were determined by analytical equations depending on photon directions. Results are tabulated for various gamma energies

  5. The GRAD high-altitude balloon flight over Antarctica

    International Nuclear Information System (INIS)

    Eichhorn, G.; Coldwell, R.L.; Dunnam, F.E.; Rester, A.C.; Trombka, J.I.; Starr, R.; Lasche, G.P.

    1989-01-01

    The Gamma Ray Advanced Detector(GRAD) consists of a n-type germanium detector inside an active bismuth-germanate Compton and charged particle shield with additional active plastic shielding across the aperture. It will be flown on a high altitude balloon at 36 km altitude at a latitude of 78 degree S over Antarctica for observations of gamma radiation emitted by the radioactive decay of 56 Co in the Supernova SN1987A, for assessment of the performance of bismuth-germanate scintillation material in the radiation environment of near space, for gathering information on the gamma-ray background over Antarctica, and for testing fault-tolerant software

  6. Experimental techniques for the detection of the high energy gamma rays of cosmic origin

    International Nuclear Information System (INIS)

    Dumitrescu, Gh.; Angelescu, T.; Radu, A.A.

    2002-01-01

    The observation of high energy gamma rays of cosmic origin in the early 90 by Volcano Ranch experiment opened a new direction of study in astrophysics. The very high energy and the very low flux of these gamma rays, posed numerous detection problems which in turn were the object of a very intense research activity. The present article tries to review the detection techniques for the high energy gamma rays of cosmic origin. In the 'Introduction' we summarize the specific problems involved in the detection of this type of radiation. 'Chapter 1' presents the classic technique based on the use of scintillation detectors. 'Chapter 2' includes the imaging atmospheric Cherenkov technique (IACT) and the sampling wavefront technique. 'Chapter 3' is dedicated to the detection of the atmospheric nitrogen. 'Chapter 4' describes issues related to the calibration of the detectors, the cross checking of the experimental data, the use of the Monte Carlo simulations and the use of the density observed at a distance of 600 m S(600), in order to estimate the primary energy. The characteristics of some future developments of the above presented techniques are included in the last chapter. (authors)

  7. Modulation of Enzymatic Activities of Dual Functional Peroxiredoxin by Gamma Irradiation

    International Nuclear Information System (INIS)

    Hong, Sung Hyun; Lee, Seung Sik; Park, Chul Hong; Chung, Byung Yeoup

    2012-01-01

    Recently, enzymes have frequently been used as catalysts in various bio-industrial, commercial, and pharmaceutical applications, because they are more stable, more efficient, and less toxic than the synthetic catalysts. However, one of their major disadvantages is their low thermostability, which leads the researchers to develop new forms of industrially important enzymes with increased resistance to inactivation and aggregation. This study describes a strategy for modifying the molecular chaperone activity of peroxiredoxin (Prx) by using gamma irradiation. Prxs are a ubiquitous family of antioxidant enzymes. Upon oxidation of their peroxidatic Cys, the molecules undergo a structural conversion from a low-molecular-weight (LMW) species acting as a peroxidase to a high-molecular-weight (HMW) complex functioning as a chaperone. In the present study, we examined the effect of gamma irradiation on PP1084 with respect to its protein structure and enzymatic function. The use of gamma irradiation as a physical treatment can increase the cohesive strength of the protein by forming cross-links. The aims of the present work were (1) to improve the chaperone activity of PP1084 by gamma irradiation, (2) to identify the 'optimal' intensity of gamma irradiation, and (3) to investigate the influence of gamma irradiation on protein hydrophobicity as related to chaperone function. Following PP1084 treatment with 30 kGy gamma irradiation, the PP1084 chaperone activity enhanced by about 3-4-fold compared with nonirradiated PP1084, while the peroxidase activity decreased. Ongoing research efforts are addressing the physical modifications of PP1084 protein by gamma irradiation

  8. Measurement and Analysis of Specific Activities of 238U, 232Th,226Ra, 40K and 137Cs in Soil Samples from Phatthalung Province (Thailand) using Gamma Ray Spectrometry

    International Nuclear Information System (INIS)

    Daoh, Murnee; Kessaratikoon, Prasong; Udomsomporn, Suchin

    2011-06-01

    Full text: Specific activity of natural (238 U , 232 T h, 226 R a and 40 K ) and anthropogenic radionuclide (137 C s) in 109 soil samples collected from 11 districts in Phathalung province have been measured and analyzed. Experimental results were obtained by using a high purity germanium (HPGe) detector and gamma spectrometry analysis system at Nuclear and Material Physics laboratory in Department of Physics Faculty of Science Thaksin University Songkhla Campus. Gamma ray radioactive standard sources 60 C o, 137 C s and 133 B a were used to calibrate the measurement system. The KCl and two reference materials (RGU-1 and RGTh-1) obtained from the International Atomic Energy Agency were also used to analyze and compute the 40 K , 238 U (or 226 R a) and 232 T h specific activity in all soil samples. The IAEA/SL-2 was also used to evaluate the specific activity of 137 C s in all soil samples. The measuring time of each sample was 10,800 seconds. It was found that specific activity ranged from 148.17 to 11276.78 Bq/kg for 40 K , 58.29 to 518.45 Bq/kg for 226 R a, 8.40 to 236.19 Bq/kg for 232 T h and 0.00 tp 12.39 Bq/kg for 137 C s with mean values of 3573.35 ± 203.89 Bq/kg, 135.89 ± 6.71 Bq/kg, 76.34 ± 5.32 Bq/kg and 1.05 ± 0.70 Bq/kg respectively. Furthermore, absorbed dose rate in air (D), radium equivalent activity (Ra e q), external hazard index (H e x), and annual effective dose rate (AEDout) of this area were also evaluated by using the mean values of specific activities of the 40 K , 226 R a and 232 T h. Moreover, the experimental results were also compared with Office of Atoms for Peace (OAP) research data, Thailand and global radioactivity measurement and evaluations. The radioactive contour maps of specific activities of natural and anthropogenic radionuclides from this study were created by using the program ArcGis Version 9.2

  9. Prompt gamma-ray activation analysis (PGAA)

    International Nuclear Information System (INIS)

    Kern, J.

    1996-01-01

    The paper deals with a brief description of the principles of prompt gamma-ray activation analysis (PGAA), with the detection of gamma-rays, the PGAA project at SINQ and with the expected performances. 8 figs., 3 tabs., 10 refs

  10. Prompt gamma-ray activation analysis (PGAA)

    Energy Technology Data Exchange (ETDEWEB)

    Kern, J [Fribourg Univ. (Switzerland). Inst. de Physique

    1996-11-01

    The paper deals with a brief description of the principles of prompt gamma-ray activation analysis (PGAA), with the detection of gamma-rays, the PGAA project at SINQ and with the expected performances. 8 figs., 3 tabs., 10 refs.

  11. The activity of selected gamma radionuclides in the Tatra National Park

    Directory of Open Access Journals (Sweden)

    Kubica Barbara

    2017-01-01

    Full Text Available Cesium is naturally occurring active metal, represented by one stable isotope 133Cs, and number of artificial, unstable, isotopes. The most common artificial isotope of cesium is 137Cs, present in the environment of the Tatra Mountains due to nuclear weapon testing in late `50, and nuclear reactor accident in Chernobyl in 1986. However in recent years the growth in biofuels use for power generation can be the next source of 137Cs emission. Burning wood cultivated on grounds contaminated by 137Cs can introduce secondary emission of this isotope to the atmosphere.This paper presents the results of determination of gamma emitting radionuclides artificial 137Cs and natural 40K in soil samples from the Tatra Mountains. Results show some differences in the vertical distribution of examined radionuclides. It was found that the change of activity of 137Cs in the soil samples depends mostly on the soil density and on the concentration of organic material. The state of “zero” 137Cs activity was developed in the form of maps.

  12. Use of proportional gas scintillator in absolute measurements of alpha-gamma emitter activities

    International Nuclear Information System (INIS)

    Tobias, C.C.B.

    1987-01-01

    The absolute activity of U-235 contained in a U 3 O 8 sample was measured utilizing a sum-coincidence circuit which selects only the alpha particles which are simultaneous with the 143 KeV and 186 KeV gamma radiations from the Th-231 (product nucleus). The alpha particles were detected by means of a new type of a gas scintillating chamber, in which the light emitted by excitation of the gas atoms, due to the passage of a charged incoming particle, has its intensity increased by the action of an applied electric field. The gamma radiations were detected by means of a NaI(Tl) 1'' x 1 1/2'' scintillation detector. The value obtained for the half-life of U-235 was compared with the data available from various observers which used different experimental techniques. It is shown tht the results, are in excellent agreement with the best international data available on the subject and that, therefore, the sum-coincidence technique constitutes an important method for such measurements. (Author) [pt

  13. Ultra-bright and highly efficient inorganic based perovskite light-emitting diodes

    Science.gov (United States)

    Zhang, Liuqi; Yang, Xiaolei; Jiang, Qi; Wang, Pengyang; Yin, Zhigang; Zhang, Xingwang; Tan, Hairen; Yang, Yang (Michael); Wei, Mingyang; Sutherland, Brandon R.; Sargent, Edward H.; You, Jingbi

    2017-06-01

    Inorganic perovskites such as CsPbX3 (X=Cl, Br, I) have attracted attention due to their excellent thermal stability and high photoluminescence quantum efficiency. However, the electroluminescence quantum efficiency of their light-emitting diodes was CsPbBr3 lattice and by depositing a hydrophilic and insulating polyvinyl pyrrolidine polymer atop the ZnO electron-injection layer to overcome these issues. As a result, we obtained light-emitting diodes exhibiting a high brightness of 91,000 cd m-2 and a high external quantum efficiency of 10.4% using a mixed-cation perovskite Cs0.87MA0.13PbBr3 as the emitting layer. To the best of our knowledge, this is the brightest and most-efficient green perovskite light-emitting diodes reported to date.

  14. Uptake and transport of positron-emitting tracer in plants

    Energy Technology Data Exchange (ETDEWEB)

    Kume, Tamikazu; Matsuhashi, Shinpei; Shimazu, Masamitsu [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; and others

    1997-03-01

    The transport of a positron-emitting isotope introduced into a plant was dynamically followed by a special observation apparatus called `Positron-Emitting Tracer Imaging System`. In the system, annihilation {gamma}-rays from the positron emitter are detected with two planer detectors (5 x 6 cm square). The water containing ca. 5 MBq/ml of {sup 18}F was fed to the cut stem of soybean for 2 min and then the images of tracer activity were recorded for 30 - 50 min. When the midrib of a leaf near the petiole was cut just before measurement, the activity in the injured leaf was decreased but detected even at the apex. This result suggests that the damaged leaf recovered the uptake of water through the lamina. Maximum tracer activities in leaves of unirradiated plant were observed within 10 min, whereas those of irradiated plant at 100 Gy were observed after over 25 min. The final activity of irradiated plant after 30 min was lower than that of unirradiated plant. In case of beans, there was a difference in the absorption behavior of the {sup 18}F-labeled water between unirradiated and irradiated samples. These results show that the system is effective to observe the uptake and transportation of water containing positron emitting tracer for the study of damage and recovery functions of plants. (author)

  15. Inhibition of [gamma]-endorphin generating endopeptidase activity of rat brain by peptides: Structure activity relationship

    NARCIS (Netherlands)

    Lebouille, J.L.M.; Visser, W.H.; Hendriks, R.W.; Nispen, J.W. van; Greven, H.M.; Burbach, J.P.H.

    1985-01-01

    Gamma-Endorphin generating endopeptidase (gammaEGE) activity is an enzyme activity which converts beta-endorphin into gamma-endorphin and beta-endorphin-(18–31). The inhibitory potency on gammaEGE activity of neuropeptides and analogues or fragments of neuropeptides was tested. Dynorphin-(1–13)

  16. Gamma-ray imaging system for real-time measurements in nuclear waste characterisation

    Science.gov (United States)

    Caballero, L.; Albiol Colomer, F.; Corbi Bellot, A.; Domingo-Pardo, C.; Leganés Nieto, J. L.; Agramunt Ros, J.; Contreras, P.; Monserrate, M.; Olleros Rodríguez, P.; Pérez Magán, D. L.

    2018-03-01

    A compact, portable and large field-of-view gamma camera that is able to identify, locate and quantify gamma-ray emitting radioisotopes in real-time has been developed. The device delivers spectroscopic and imaging capabilities that enable its use it in a variety of nuclear waste characterisation scenarios, such as radioactivity monitoring in nuclear power plants and more specifically for the decommissioning of nuclear facilities. The technical development of this apparatus and some examples of its application in field measurements are reported in this article. The performance of the presented gamma-camera is also benchmarked against other conventional techniques.

  17. Gamma-ray mirror technology for NDA of spent fuel

    Energy Technology Data Exchange (ETDEWEB)

    Descalle, M. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ruz-Armendariz, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Decker, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Alameda, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Brejnholt, N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Soufli, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Robinson, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Dreyer, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pivovaroff, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ziock, K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Chichester, D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Watson, S. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Trellue, H. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-28

    Direct measurements of gamma rays emitted by fissile material have been proposed as an alternative to measurements of the gamma rays from fission products. From a safeguards applications perspective, direct detection of uranium (U) and plutonium (Pu) K-shell fluorescence emission lines and specific lines from some of their isotopes could lead to improved shipper-receiver difference or input accountability at the start of Pu reprocessing. However, these measurements are difficult to implement when the spent fuel is in the line-of-sight of the detector, as the detector is exposed to high rates dominated by fission product emissions. To overcome the combination of high rates and high background, grazing incidence multilayer mirrors have been proposed as a solution to selectively reflect U and Pu hard X-ray and soft gamma rays in the 90 to 420 keV energy into a high-purity germanium (HPGe) detector shielded from the direct line-of-sight of spent fuel. Several groups demonstrated that K-shell fluorescence lines of U and Pu in spent fuel could be detected with Ge detectors. In the field of hard X-ray optics the performance of reflective multilayer coated reflective optics was demonstrated up to 645 keV at the European Synchrotron Radiation Facility. Initial measurements conducted at Oak Ridge National Laboratory with sealed sources and scoping experiments conducted at the ORNL Irradiated Fuels Examination Laboratory (IFEL) with spent nuclear fuel further demonstrated the pass-band properties of multilayer mirrors for reflecting specific emission lines into 1D and 2D HPGe detectors, respectively.

  18. The metrological activity determination of {sup 238} U and {sup 230} Th by gamma spectrometry to industrial fuel-cycle application

    Energy Technology Data Exchange (ETDEWEB)

    Almeida M, M.C. de; Delgado, J.U.; Poledna, R. [Instituto de Radioprotecao e Dosimetria- IRD/SEMRA, CNEN, Av. Salvador Allende s/n, Recreio, CEP 22780-160, Rio de Janeiro (Brazil)]. e-mail: marcandida@yahoo.com.br

    2006-07-01

    This work describes the difficulty for determining the activity of {sup 238} U and {sup 230} Th using gamma spectrometry due to the low gamma-ray emission probabilities of 92 and 67 keV, and, mainly, the associated high uncertainties about 13 and 11%, respectively. {sup 230} Th is a {sup 238} U daughter and it is product from uranium mills and refineries. {sup 230} Th decays to {sup 226} Ra and this decay has to be measured because these radionuclides are not in secular equilibrium with their daughter products, besides the gamma-energies have high uncertainties in the emission probabilities. These radionuclides, mostly {sup 238} U, are important in the nuclear fuel-cycle, since the mining of uranium ore, where the nominal isotopic content of natural uranium is 99.27% of {sup 238} U, until the irradiated fuel reprocessing, where this isotope, a fertile material, is recovered to be used again. The uranium and thorium are considered safeguarded nuclear materials and the metrology tries to calibrate and standardize these materials to improve the activity determination techniques applied in different fuel-cycle scopes. The essential characteristics of the safeguarded materials are low gamma energies (less than 100 keV) and emission probabilities but with high uncertainties. In this way, the metrology can contribute to homeland security defense against illicit nuclear trafficking with the identification and quantification of the safeguarded radionuclides such as uranium and thorium, using specific gamma window energy and high resolution planar or coaxial germanium detector. The efficiency curve is obtained from the reference source spectrum considering the photopeak areas corresponding the standard activities. This curve depends on radiation energy, sample geometry, photon attenuation (sample absorption and material absorption between sample-detector), dead time and sample-detector position. The metrological activity determinations of {sup 238} U solid sources, and of

  19. Determination Performance Of Gamma Spectrometry Co-Axial HPGE Detector In Radiochemistry And Environment Group, Nuclear Malaysia

    International Nuclear Information System (INIS)

    Mei-Woo, Y.

    2014-01-01

    Gamma Spectrometry System is used to measure qualitatively and quantitatively a gamma emitting radionuclide. The accuracy of the measurement very much depends on the performance specifications of the HPGe detectors. From this study it found that all the seven co-axial HPGe detectors in Radiochemistry and Environment Group, Nuclear Malaysia are in good working conditions base on the verification of performance specifications namely Resolution, Peak Shape, Peak-to-Compton ratio and Relative Efficiency against the warranted value from the manufacturers. (author)

  20. Blue emitting organic semiconductors under high pressure

    DEFF Research Database (Denmark)

    Knaapila, Matti; Guha, Suchismita

    2016-01-01

    This review describes essential optical and emerging structural experiments that use high GPa range hydrostatic pressure to probe physical phenomena in blue-emitting organic semiconductors including π-conjugated polyfluorene and related compounds. The work emphasizes molecular structure and inter......This review describes essential optical and emerging structural experiments that use high GPa range hydrostatic pressure to probe physical phenomena in blue-emitting organic semiconductors including π-conjugated polyfluorene and related compounds. The work emphasizes molecular structure...... and intermolecular self-organization that typically determine transport and optical emission in π-conjugated oligomers and polymers. In this context, hydrostatic pressure through diamond anvil cells has proven to be an elegant tool to control structure and interactions without chemical intervention. This has been...... and intermolecular interactions on optical excitations, electron–phonon interaction, and changes in backbone conformations. This picture is connected to the optical high pressure studies of other π-conjugated systems and emerging x-ray scattering experiments from polyfluorenes which provides a structure-property map...

  1. Compton effect thermally activated depolarization dosimeter

    Science.gov (United States)

    Moran, Paul R.

    1978-01-01

    A dosimetry technique for high-energy gamma radiation or X-radiation employs the Compton effect in conjunction with radiation-induced thermally activated depolarization phenomena. A dielectric material is disposed between two electrodes which are electrically short circuited to produce a dosimeter which is then exposed to the gamma or X radiation. The gamma or X-radiation impinging on the dosimeter interacts with the dielectric material directly or with the metal composing the electrode to produce Compton electrons which are emitted preferentially in the direction in which the radiation was traveling. A portion of these electrons becomes trapped in the dielectric material, consequently inducing a stable electrical polarization in the dielectric material. Subsequent heating of the exposed dosimeter to the point of onset of ionic conductivity with the electrodes still shorted through an ammeter causes the dielectric material to depolarize, and the depolarization signal so emitted can be measured and is proportional to the dose of radiation received by the dosimeter.

  2. Gamma activation analysis with microtron

    International Nuclear Information System (INIS)

    Fiderkiewicz, A.; Kierzek, J.; Parus, J.; Swiderska-Kowalczyk, M.; Wolski, W.; Zoltowski, T.

    1989-01-01

    The physical principles of gamma activation analysis, its capabilities as well as its application to analyse polymetallic ores with use of mean power microtron are presented. Limits of detection and determination for above twenty elements occurring in those ores with use of short- and longlived radioisotopes are specified. The work contains conception of construction of race-track microtron with electrons energy adjusted in 10-30 MeV range and with current not less than 20 μA. Besides the development of microtrons, the reason for choosing the race-track construction for gamma activation analysis is given. 69 refs., 35 figs., 5 tabs. (author)

  3. In-situ high-resolution gamma-spectrometric survey of burial ground-monitoring wells

    International Nuclear Information System (INIS)

    Bowman, W.W.

    1981-09-01

    In situ high resolution gamma-ray spectrometry with an intrinsic germanium detector assembly of special design surveyed the burial ground monitoring wells to locate and identify gamma emitters that may have migrated from the burial trenches toward the water table. Gamma-ray spectra were acquired as a function of depth in each well and recorded on magnetic tape. These spectra were reduced by a series of computer programs to produce count rate versus depth profiles for natural and man-made activities. The original spectra and the profiles have been archived on magnetic tape for comparison with similar future surveys. Large amounts of man-made activities were observed in some of the burial trenches; however, below the trench bottoms, only very low but detectable amounts of 60 Co and 137 Cs were observed in eleven wells. The highest level of man-made gamma activity observed below the trench bottoms has a count rate roughly equal to that observed for uranium daughter activities which are natural to the subsoil

  4. Characterisation of imperial college reactor centre legacy waste using gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Shuhaimi, Alif Imran Mohd

    2016-01-01

    Waste characterisation is a principal component in waste management strategy. The characterisation includes identification of chemical, physical and radiochemical parameters of radioactive waste. Failure to determine specific waste properties may result in sentencing waste packages which are not compliant with the regulation of long term storage or disposal. This project involved measurement of intensity and energy of gamma photons which may be emitted by radioactive waste generated during decommissioning of Imperial College Reactor Centre (ICRC). The measurement will use High Purity Germanium (HPGe) as Gamma-ray detector and ISOTOPIC-32 V4.1 as analyser. In order to ensure the measurements provide reliable results, two quality control (QC) measurements using difference matrices have been conducted. The results from QC measurements were used to determine the accuracy of the ISOTOPIC software

  5. Characterisation of imperial college reactor centre legacy waste using gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Shuhaimi, Alif Imran Mohd [Nuclear Energy Department, Regulatory Economics & Planning Division, Tenaga Nasional Berhad (Malaysia)

    2016-01-22

    Waste characterisation is a principal component in waste management strategy. The characterisation includes identification of chemical, physical and radiochemical parameters of radioactive waste. Failure to determine specific waste properties may result in sentencing waste packages which are not compliant with the regulation of long term storage or disposal. This project involved measurement of intensity and energy of gamma photons which may be emitted by radioactive waste generated during decommissioning of Imperial College Reactor Centre (ICRC). The measurement will use High Purity Germanium (HPGe) as Gamma-ray detector and ISOTOPIC-32 V4.1 as analyser. In order to ensure the measurements provide reliable results, two quality control (QC) measurements using difference matrices have been conducted. The results from QC measurements were used to determine the accuracy of the ISOTOPIC software.

  6. Automatic control by natural gamma radiation emitted by coal; Control Automatico mediante Radiometria Gamma Natural de la Cenizas de los Carbones

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    Due to the characteristics of its coal and orebody, Monsacro shaft was chosen to host the test. The ash percentage of the different coal seams was carried out by two different methods: Traditional analysis in laboratory. Analysis by means of natural gamma radiation emitted by coal. The following conclusions were obtained after the test: Neither during the mounting nor during the test, a problem was encountered in the working of the radioactive methods. The absolute error between the two methods was minimum. The radioactive analysis is total (this means that the whole coal is analysed) and it is carried out in short period of time. The traditional one is just partial, and could take a few hours to accomplish it. The radioactive one is done in the wagon or in the belt conveyor directly, meanwhile the traditional one needs sample takers permanently. The investment cost of the radioactivity method is amortized within two years. (Author)

  7. Report on the IAEA-CU-2006-08 proficiency test on the determination of gamma emitting radionuclides in sea water

    International Nuclear Information System (INIS)

    Shakhashiro, A.; Sansone, U.; Martin, P.; Makarewicz, M.; Mohagheghi, A.

    2007-03-01

    The Cooperative Monitoring Centre of Sandia National Laboratories of the United States (SNL) has initiated the Radiation Measurements Cross Calibration (RMCC) project. The RMCC aims to promote regional cooperation in the Middle East for preparedness for radiological emergencies. The International Atomic Energy Agency (IAEA) is cooperating with Sandia National Laboratories in this project. On a practical level, the initial aim of the RMCC is to establish a network of experts to cooperatively standardize nuclear monitoring and measurement capabilities in the Middle East by applying internationally recognized standards for laboratory radiation measurements. One of the project activities is to assist selected radiation measurement laboratories to participate in a quality assurance program and proficiency tests. During the second Workshop of the RMCC Project, organised by Sandia National Laboratories in Doha, Qatar, 12-17 November 2005, it was agreed to request the Chemistry Unit at the Agency's Seibersdorf laboratories to organise a special Proficiency Test (PT) for participants, for gamma-emitters in sea water. It is well known that proficiency testing is a method for regularly assessing the accuracy of the analytical data produced by the laboratories of particular measurements. According to the requirements of the RMCC project the IAEA-CU-2006-08 proficiency test (PT) on the determination of gamma emitting radionuclides in sea water was conducted by the Chemistry Unit of the IAEA's Laboratories located in Seibersdorf (Austria). The Chemistry Unit is actively involved in the production and characterization of matrix reference materials of terrestrial origin, widely used for method validation and organization of proficiency tests and intercomparison studies. The Chemistry Unit is a part of the Physics, Chemistry and Instrumentation Laboratory. This report describes the sample preparation methodology, data evaluation approach, summary evaluation of each nuclide and

  8. Design of a software for gamma detector efficiency

    International Nuclear Information System (INIS)

    Lopez, G.

    2011-01-01

    Gamma spectroscopy with highly-pure-germanium detector is one of the most used method for qualitative and quantitative analysis of samples. Nevertheless Gamma spectroscopy results require to be corrected, first for taking into account the self-shielding effect that represents the absorption of the photons by the sample itself and secondly for correcting the fact that 2 photons emitted simultaneously with energy E 1 and E 2 are likely to be simultaneously detected and then counted as a single photon with an energy E 1 +E 2 . This effect is called gamma-gamma coincidence. A software has been designed to simulate both effect and produce correcting factors in the case of cylindrical geometries. This software has been validated on Americium 241 for the self-shielding effect and on Cesium 134 for gamma-gamma coincidence. (A.C.)

  9. Photon Activation Analysis Of Light Elements Using 'Non-Gamma' Radiation Spectroscopy - The Instrumental Determination Of Phosphorus

    International Nuclear Information System (INIS)

    Segebade, Christian; Goerner, Wolf

    2011-01-01

    Unlike metal determinations the analysis of light elements (e.g., carbon, oxygen, phosphorus) is frequently problematic, in particular if analysed instrumentally. In photon activation analysis (PAA) the respective activation products do not emit gamma radiation in the most cases. Usually, annihilation quanta counting and subsequent decay curve analysis have been used for determinations of C, N, O, and F. However, radiochemical separation of the respective radioisotopes mostly is indispensable. For several reasons, some of the light elements cannot be analysed following this procedure, e.g. phosphorus. In this contribution the instrumental PAA of phosphorus in organic matrix by activation with bremsstrahlung of an electron linear accelerator and subsequent beta spectroscopy is described. The accuracy of the results was excellent as obtained by analysis of a BCR Reference Material.

  10. Improvement in minimum detectable activity for low energy gamma by optimization in counting geometry

    Directory of Open Access Journals (Sweden)

    Anil Gupta

    2017-01-01

    Full Text Available Gamma spectrometry for environmental samples of low specific activities demands low minimum detection levels of measurement. An attempt has been made to lower the gamma detection level of measurement by optimizing the sample geometry, without compromising on the sample size. Gamma energy of 50–200 keV range was chosen for the study, since low energy gamma photons suffer the most self-attenuation within matrix. The simulation study was carried out using MCNP based software “EffCalcMC” for silica matrix and cylindrical geometries. A volume of 250 ml sample geometry of 9 cm diameter is optimized as the best suitable geometry for use, against the in-practice 7 cm diameter geometry of same volume. An increase in efficiency of 10%–23% was observed for the 50–200 keV gamma energy range and a corresponding lower minimum detectable activity of 9%–20% could be achieved for the same.

  11. Gas lantern mantle: a low activity alpha particle source

    International Nuclear Information System (INIS)

    Mukherjee, B.; Manzoor, S.

    1991-01-01

    Commercially available gas lantern mantles contain a substantial amount of radioactive ThO 2 . Gas lantern mantles purchased from a Sydney camping shop were incinerated, deposited as a thin layer on a aluminium planchette, and the emitted alpha spectrum was measured with a silicon surfacer barrier detector. The specific activity of the samples was estimated by high resolution gamma spectroscopy using a high purity germanium detector as well as CR-39 solid state nuclear track detectors. The micro-morphology of the incinerated powder was analysed by scanning electron microscopy. The depth dose and LET distribution of alpha particles in soft tissue were calculated from the energy spectrum. 12 refs., 2 tabs., 5 figs

  12. The activity of {gamma}-emitters as measured by ionisation chambers the determination of the specific emission coefficient {gamma} for some radio-elements (1961); Mesure de l'activite des emetteurs {gamma} par chambre d'ionisation. Determination du coefficient specifique d'emission {gamma} de quelques radioelements (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Engelmann, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-06-15

    The object of this work is to study techniques of measurement using the gamma ionisation chamber, making it possible either to measure the activities of radioactive sources, or to determine the specific emission coefficient {gamma} (or the coefficient K) of a given radioelement. The ionisation chambers studied belong to two categories: graphites cavity-chambers, and 4 {pi} {gamma} chambers. For the cavity-chamber measurements, the different correction factors of which account must be taken have been calculated, in particular the geometric and hygrometric corrections. The absorption and auto-absorption corrections have led to the introduction of the notion of the 'effective energy {gamma}' of a radioelement. In the case of 4 {pi} {gamma} chambers, it has been shown that appropriately shaped electrodes make it possible to improve their performances. One of the chambers described permits the measurement of {beta} emitters using the associated Bremsstrahlung. In order to measure the K coefficient of some radioelements, it has been found useful a 4 {pi} {gamma} chamber with graphite walls, the measurement being carried out by comparison with a radium standard. The validity of the method was checked with radioelements for whom the K coefficient values are well-known ({sup 24}Na, {sup 60}Co, {sup 131}I, {sup 198}Au). For other radioelements, the following values were obtained (expressed in r cm{sup 3} mc{sup -1} h{sup -1}): {sup 51}Cr: 0,18; {sup 56}Mn: 8,8; {sup 65}Zn: 3,05; {sup 124}Sb: 9,9; {sup 134}Cs: 9,3; {sup 137}Cs: 3,35; {sup 141}Ce: 0,46; {sup 170}Tm: 0,023; {sup 192}Ir: 24,9; {sup 203}Hg: 1,18; These values have been corrected for the contribution to the dose of the fluorescent radiation which may be emitted by the source, except in the case of Tm{sup 170}. In the last part of this work, the performances of the different electro-metric devices used were compared. (author) [French] Le but de ce travail est d'etudier les techniques de mesure par

  13. Human gamma oscillations during slow wave sleep.

    Directory of Open Access Journals (Sweden)

    Mario Valderrama

    Full Text Available Neocortical local field potentials have shown that gamma oscillations occur spontaneously during slow-wave sleep (SWS. At the macroscopic EEG level in the human brain, no evidences were reported so far. In this study, by using simultaneous scalp and intracranial EEG recordings in 20 epileptic subjects, we examined gamma oscillations in cerebral cortex during SWS. We report that gamma oscillations in low (30-50 Hz and high (60-120 Hz frequency bands recurrently emerged in all investigated regions and their amplitudes coincided with specific phases of the cortical slow wave. In most of the cases, multiple oscillatory bursts in different frequency bands from 30 to 120 Hz were correlated with positive peaks of scalp slow waves ("IN-phase" pattern, confirming previous animal findings. In addition, we report another gamma pattern that appears preferentially during the negative phase of the slow wave ("ANTI-phase" pattern. This new pattern presented dominant peaks in the high gamma range and was preferentially expressed in the temporal cortex. Finally, we found that the spatial coherence between cortical sites exhibiting gamma activities was local and fell off quickly when computed between distant sites. Overall, these results provide the first human evidences that gamma oscillations can be observed in macroscopic EEG recordings during sleep. They support the concept that these high-frequency activities might be associated with phasic increases of neural activity during slow oscillations. Such patterned activity in the sleeping brain could play a role in off-line processing of cortical networks.

  14. Enhanced Dendritic Cell-Mediated Antigen-Specific CD4+ T Cell Responses: IFN-Gamma Aids TLR Stimulation

    Directory of Open Access Journals (Sweden)

    Kuo-Ching Sheng

    2013-01-01

    Full Text Available Phenotypic maturation and T cell stimulation are two functional attributes of DCs critical for immune induction. The combination of antigens, including those from cancer, with Toll-like receptor (TLR ligands induces far superior cellular immune responses compared to antigen alone. In this study, IFN-gamma treatment of bone marrow-derived DC, followed by incubation with the TLR2, TLR4, or TLR9 agonists, enhanced DC activation compared to TLR ligation alone. Most notably, the upregulation of CD40 with LPS stimulation and CD86 with CpG stimulation was observed in in vitro cultures. Similarly, IFN-gamma coinjected with TLR ligands was able to promote DC activation in vivo, with DCs migrating from the site of immunization to the popliteal lymph nodes demonstrating increased expression of CD80 and CD86. The heightened DC activation translated to a drastic increase in T cell stimulatory capacity in both antigen independent and antigen dependent fashions. This is the first time that IFN-gamma has been shown to have a combined effect with TLR ligation to enhance DC activation and function. The results demonstrate the novel use of IFN-gamma together with TLR agonists to enhance antigen-specific T cell responses, for applications in the development of enhanced vaccines and drug targets against diseases including cancer.

  15. Principles and techniques of gamma ray tracers

    International Nuclear Information System (INIS)

    Claxton, K.T.

    1978-01-01

    Radioactive tracer techniques provide a very sensitive means of studying physical and chemical processes in a whole variety of different media. Some of the techniques and principles of radioactive tracers and their application to practical engineering systems are discussed. Information which has been found useful in the design of high temperature liquid sodium facilities employing radio-tracers, is presented. The report deals solely with the use of gamma-emitting species as the tracer. These find particular application for in-situ studies on engineering systems where the highly penetrating properties of gamma rays are needed for detection through strongly absorbent media such as stainless steel pepe walls. (author)

  16. General description and first results with the ORIS-LMRI 4 {pi} {gamma} metering chamber; Descripcion general y primeros resultados con la camara 4 {pi} {gamma} metrologica ORIS-LMRI

    Energy Technology Data Exchange (ETDEWEB)

    Tejera R, A; Becerril V, A; Cortes P, A

    1990-04-15

    A problem that present the ionization chambers is that the response for the radiation is global, that is to say that it cannot discriminate against selectively the relating responses at different energies, if these impact simultaneously in the active volume. This is a reason to calibrate the chambers, if is possible, with gamma monoenergetic emitting and by average calculations to complete the response curve with gamma emitting of well-known yields. To obtain the calibration coefficients and may used them, it is necessary that so much the standardized radioisotopes as the solutions by calibrating, are contained in vessels with the same geometry and the same quantity. In the exposed case, pattern solutions of 5 ml were used contained in glass cruets of 10 ml. The problem solutions are contained in same cruets to those of the patterns. The first results obtained with the ORIS-LMRI 4 {pi} {gamma} metering chamber are presented. (Author)

  17. Application of low-cost Gallium Arsenide light-emitting-diodes as kerma dosemeter and fluence monitor for high-energy neutrons

    International Nuclear Information System (INIS)

    Mukherjee, B.; Simrock, S.; Khachan, J.; Rybka, D.; Romaniuk, R.

    2007-01-01

    Displacement damage (DD) caused by fast neutrons in unbiased Gallium Arsenide (GaAs) light emitting diodes (LED) resulted in a reduction of the light output. On the other hand, a similar type of LED irradiated with gamma rays from a 60 Co source up to a dose level in excess of 1.0 kGy (1.0 x 10 5 rad) was found to show no significant drop of the light emission. This phenomenon was used to develop a low cost passive fluence monitor and kinetic energy released per unit mass dosemeter for accelerator-produced neutrons. These LED-dosemeters were used to assess the integrated fluence of photoneutrons, which were contaminated with a strong Bremsstrahlung gamma-background generated by the 730 MeV superconducting electron linac driving the free electron laser in Hamburg (FLASH) at Deutsches Elektronen-Synchrotron. The applications of GaAs LED as a routine neutron fluence monitor and DD precursor for the electronic components located in high-energy accelerator environment are highlighted. (authors)

  18. Spontaneous Gamma Activity in Schizophrenia.

    Science.gov (United States)

    Hirano, Yoji; Oribe, Naoya; Kanba, Shigenobu; Onitsuka, Toshiaki; Nestor, Paul G; Spencer, Kevin M

    2015-08-01

    A major goal of translational neuroscience is to identify neural circuit abnormalities in neuropsychiatric disorders that can be studied in animal models to facilitate the development of new treatments. Oscillations in the gamma band (30-100 Hz) of the electroencephalogram have received considerable interest as the basic mechanisms underlying these oscillations are understood, and gamma abnormalities have been found in schizophrenia (SZ). Animal models of SZ based on hypofunction of the N-methyl-d-aspartate receptor (NMDAR) demonstrate increased spontaneous broadband gamma power, but this phenomenon has not been identified clearly in patients with SZ. To examine spontaneous gamma power and its relationship to evoked gamma oscillations in the auditory cortex of patients with SZ. We performed a cross-sectional study including 24 patients with chronic SZ and 24 matched healthy control participants at the Veterans Affairs Boston Healthcare System from January 1, 2009, through December 31, 2012. Electroencephalograms were obtained during auditory steady-state stimulation at multiple frequencies (20, 30, and 40 Hz) and during a resting state in 18 participants in each group. Electroencephalographic activity in the auditory cortex was estimated using dipole source localization. Auditory steady-state response (ASSR) measures included the phase-locking factor and evoked power. Spontaneous gamma power was measured as induced (non-phase-locked) gamma power in the ASSR data and as total gamma power in the resting-state data. The ASSR phase-locking factor was reduced significantly in patients with SZ compared with controls for the 40-Hz stimulation (mean [SD], 0.075 [0.028] vs 0.113 [0.065]; F1,46 = 6.79 [P = .012]) but not the 20- or the 30-Hz stimulation (0.042 [0.038] vs 0.043 [0.034]; F1,46 = 0.006 [P = .938] and 0.084 [0.040] vs 0.098 [0.050]; F1,46 = 1.605 [P = .212], respectively), repeating previous findings. The mean [SD] broadband-induced (30

  19. Study of the gamma spectrum of 16N with a BGO detector, for the purpose of calibration and of determining the fluorine grade of mineral samples

    International Nuclear Information System (INIS)

    Castro-Garcia, M.P.; Alonso-Sanchez, T.; Rey-Ronco, M.A.

    2013-01-01

    The study of 16 N's gamma spectrum has two main uses: calibrating gamma detectors in a high energy range, and determining the fluorine grade of mineral samples of fluorite. This article examines and compares the gamma ray spectrum of 16 N as recorded by a Bi 4 GeO 12 detector, as well as the resolution of this detector at high energy levels, and the signal-background relationship of an experimental laboratory cyclic activation unit. 16 N is the product of the reaction 9-F-19(n,α)7-N-16, which takes place during the neutron activation of mineral samples of fluorspar, and its production depends, among other factors, upon the grade of fluorite. The technique used in this study is cyclic-type neutron activation for recording delayed gamma rays, carried out with an americium-beryllium neutron source with an activity of 1 Ci. Lastly, a correlation is established between the area below the peak amount of 16 N emitted by the sample, and the sample's fluorite grade. (author)

  20. High energy gamma-ray production in nuclear reactions

    International Nuclear Information System (INIS)

    Pinston, J.A.; Nifenecker, H.; Nifenecker, H.

    1989-01-01

    Experimental techniques used to study high energy gamma-ray production in nuclear reactions are reviewed. High energy photon production in nucleus-nucleus collisions is discussed. Semi-classical descriptions of the nucleus-nucleus gamma reactions are introduced. Nucleon-nucleon gamma cross sections are considered, including theoretical aspects and experimental data. High energy gamma ray production in proton-nucleus reactions is explained. Theoretical explanations of photon emission in nucleus-nucleus collisions are treated. The contribution of charged pion currents to photon production is mentioned

  1. The Generalized Gamma-DBN for High-Resolution SAR Image Classification

    Directory of Open Access Journals (Sweden)

    Zhiqiang Zhao

    2018-06-01

    Full Text Available With the increase of resolution, effective characterization of synthetic aperture radar (SAR image becomes one of the most critical problems in many earth observation applications. Inspired by deep learning and probability mixture models, a generalized Gamma deep belief network (g Γ-DBN is proposed for SAR image statistical modeling and land-cover classification in this work. Specifically, a generalized Gamma-Bernoulli restricted Boltzmann machine (gΓB-RBM is proposed to capture high-order statistical characterizes from SAR images after introducing the generalized Gamma distribution. After stacking the g Γ B-RBM and several standard binary RBMs in a hierarchical manner, a gΓ-DBN is constructed to learn high-level representation of different SAR land-covers. Finally, a discriminative neural network is constructed by adding an additional predict layer for different land-covers over the constructed deep structure. Performance of the proposed approach is evaluated via several experiments on some high-resolution SAR image patch sets and two large-scale scenes which are captured by ALOS PALSAR-2 and COSMO-SkyMed satellites respectively.

  2. Synthesis of [diene-"1"4C] curcumin at high specific activity

    International Nuclear Information System (INIS)

    Filer, Crist N.; Lacy, James M.; Wright, Christopher

    2016-01-01

    An efficient method is described to label curcumin with "1"4C at high specific activity. - Highlights: • This paper describes the synthesis of ["1"4C] Curcumin at the highest specific activity and total activity amount yet reported. • The "1"4C label was installed in the diene framework of Curcumin. • This paper also describes the characterization of ["1"4C] Curcumin by HPLC and mass spectrometry.

  3. Harvesting Triplet Excitons with Exciplex Thermally Activated Delayed Fluorescence Emitters toward High Performance Heterostructured Organic Light-Emitting Field Effect Transistors.

    Science.gov (United States)

    Song, Li; Hu, Yongsheng; Liu, Zheqin; Lv, Ying; Guo, Xiaoyang; Liu, Xingyuan

    2017-01-25

    The utilization of triplet excitons plays a key role in obtaining high emission efficiency for organic electroluminescent devices. However, to date, only phosphorescent materials have been implemented to harvest the triplet excitons in the organic light-emitting field effect transistors (OLEFETs). In this work, we report the first incorporation of exciplex thermally activated delayed fluorescence (TADF) emitters in heterostructured OLEFETs to harvest the triplet excitons. By developing a new kind of exciplex TADF emitter constituted by m-MTDATA (4,4',4″-tris(N-3-methylphenyl-N-phenylamino)triphenylamine) as the donor and OXD-7 (1,3-bis[2-(4-tert-butylphenyl)-1,3,4-oxadiazo-5-yl]benzene) as the acceptor, an exciton utilization efficiency of 74.3% for the devices was achieved. It is found that the injection barrier between hole transport layer and emission layer as well as the ratio between donor and acceptor would influence the external quantum efficiency (EQE) significantly. Devices with a maximum EQE of 3.76% which is far exceeding the reported results for devices with conventional fluorescent emitters were successfully demonstrated. Moreover, the EQE at high brightness even outperformed the result for organic light-emitting diode based on the same emitter. Our results demonstrate that the exciplex TADF emitters can be promising candidates to develop OLEFETs with high performance.

  4. Search for solar axion emission from $^7$Li and D(p,$\\gamma)^3$He nuclear decays with the CAST $\\gamma$-ray calorimeter

    CERN Document Server

    Andriamonje, S.; Autiero, D.; Barth, K.; Belov, A.; Beltran, B.; Brauninger, H.; Carmona, J.M.; Cebrian, S.; Collar, J.I.; Dafni, T.; Davenport, M.; Di Lella, L.; Eleftheriadis, C.; Englhauser, J.; Fanourakis, G.; Ferrer-Ribas, E.; Fischer, H.; Franz, J.; Friedrich, P.; Geralis, T.; Giomataris, I.; Gninenko, S.; Gomez, H.; Hasinoff, M.; Heinsius, F.H.; Hoffmann, D.H.H.; Irastorza, I.G.; Jacoby, J.; Jakovcic, K.; Kang, D.; Konigsmann, K.; Kotthaus, R.; Krcmar, M.; Kousouris, K.; Kuster, M.; Lakic, B.; Lasseur, C.; Liolios, A.; Ljubicic, A.; Lutz, G.; Luzon, G.; Miller, D.W.; Morales, J.; Ortiz, A.; Papaevangelou, T.; Placci, A.; Raffelt, G.; Riege, H.; Rodriguez, A.; Ruz, J.; Savvidis, I.; Semertzidis, Y.; Serpico, P.; Stewart, L.; Vieira, J.D.; Villar, J.; Vogel, J.; Walckiers, L.; Zioutas, K.

    2010-01-01

    We present the results of a search for a high-energy axion emission signal from 7Li (0.478 MeV) and D(p,gamma)3He (5.5 MeV) nuclear transitions using a low-background gamma-ray calorimeter during Phase I of the CAST experiment. These so-called "hadronic axions" could provide a solution to the long-standing strong-CP problem and can be emitted from the solar core from nuclear M1 transitions. This is the first such search for high-energy pseudoscalar bosons with couplings to nucleons conducted using a helioscope approach. No excess signal above background was found.

  5. Radiation emitting devices regulations

    International Nuclear Information System (INIS)

    1970-01-01

    The Radiation Emitting Devices Regulations are the regulations referred to in the Radiation Emitting Devices Act and relate to the operation of devices. They include standards of design and construction, standards of functioning, warning symbol specifications in addition to information relating to the seizure and detention of machines failing to comply with the regulations. The radiation emitting devices consist of the following: television receivers, extra-oral dental x-ray equipment, microwave ovens, baggage inspection x-ray devices, demonstration--type gas discharge devices, photofluorographic x-ray equipment, laser scanners, demonstration lasers, low energy electron microscopes, high intensity mercury vapour discharge lamps, sunlamps, diagnostic x-ray equipment, ultrasound therapy devices, x-ray diffraction equipment, cabinet x-ray equipment and therapeutic x-ray equipment

  6. Energy spectrum of lightning gamma emission

    Energy Technology Data Exchange (ETDEWEB)

    Chubenko, A.P. [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Karashtin, A.N. [Research Radiophysics Institute, Nizhny Novgorod (Russian Federation); Ryabov, V.A., E-mail: ryabov@x4u.lebedev.r [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Shepetov, A.L. [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Antonova, V.P.; Kryukov, S.V. [Ionosphere Institute, Almaty (Kazakhstan); Mitko, G.G.; Naumov, A.S.; Pavljuchenko, L.V. [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Ptitsyn, M.O., E-mail: ptitsyn@lpi.r [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Shalamova, S.Ya. [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Shlyugaev, Yu.V. [Research Radiophysics Institute, Nizhny Novgorod (Russian Federation); Vildanova, L.I. [Tien-Shan Mountain Cosmic Ray Station, Almaty (Kazakhstan); Zybin, K.P. [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Gurevich, A.V., E-mail: alex@lpi.r [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation)

    2009-08-10

    The results of gamma emission observations obtained during thunderstorms at Tien-Shan Mountain Cosmic Ray Station are presented. The energy spectrum radiation of the stepped leader gamma radiation is measured. The total energy of stepped leader emitted in gamma rays is estimated as 10{sup -3}-10{sup -2} J. The experimental results are in an agreement with the runaway breakdown mechanism.

  7. Energy spectrum of lightning gamma emission

    International Nuclear Information System (INIS)

    Chubenko, A.P.; Karashtin, A.N.; Ryabov, V.A.; Shepetov, A.L.; Antonova, V.P.; Kryukov, S.V.; Mitko, G.G.; Naumov, A.S.; Pavljuchenko, L.V.; Ptitsyn, M.O.; Shalamova, S.Ya.; Shlyugaev, Yu.V.; Vildanova, L.I.; Zybin, K.P.; Gurevich, A.V.

    2009-01-01

    The results of gamma emission observations obtained during thunderstorms at Tien-Shan Mountain Cosmic Ray Station are presented. The energy spectrum radiation of the stepped leader gamma radiation is measured. The total energy of stepped leader emitted in gamma rays is estimated as 10 -3 -10 -2 J. The experimental results are in an agreement with the runaway breakdown mechanism.

  8. Study of {gamma}'s in Naiade; Etude des gamma de Naiade

    Energy Technology Data Exchange (ETDEWEB)

    Millot, J P; Rastoin, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    Following a study of the gamma sources, the flux of gamma of different energies in the swimming pool is investigated. The biological dose can thus be obtained by calculation, and compared with the results given by photographic plates. The influence of photoneutrons is estimated by calculation, and research is being carried out on their influence on the thermal neutron flux curve on the axis of the uranium plate, with the plate emitting neutrons and with the plate protected by boral. (author) [French] Apres l'etude des sources de gamma, l'on etudie le flux de gamma de differentes energies dans la piscine. La dose biologique peut etre obtenue ainsi par le calcul et comparee avec les resultats donnes par les plaques photographiques. L'influence des photoneutrons est estimee par le calcul et l'on recherche leur influence sur la courbe de flux de neutrons thermiques sur l'axe de la plaque d'uranium, la plaque emettant des neutrons et la plaque protegee par du boral. (auteur)

  9. The CXC chemokines gamma interferon (IFN-gamma)-inducible protein 10 and monokine induced by IFN-gamma are released during severe melioidosis

    NARCIS (Netherlands)

    Lauw, F. N.; Simpson, A. J.; Prins, J. M.; van Deventer, S. J.; Chaowagul, W.; White, N. J.; van der Poll, T.

    2000-01-01

    Gamma interferon (IFN-gamma)-inducible protein 10 (IP-10) and monokine induced by IFN-gamma (Mig) are related CXC chemokines which bind to the CXCR3 receptor and specifically target activated T lymphocytes and natural killer (NK) cells. The production of IP-10 and Mig by various cell types in vitro

  10. SWEPP gamma-ray spectrometer system software test plan and report

    International Nuclear Information System (INIS)

    Femec, D.A.

    1994-09-01

    The SWEPP Gamma-Ray Spectrometer (SGRS) System has been developed by the Radiation Measurements and Development Unit of the Idaho National Engineering Laboratory to assist in the characterization of the radiological contents of contact-handled waste containers at the Stored Waste Examination Pilot Plant (SWEPP). In addition to determining the concentrations of gamma-ray-emitting radionuclides, the software also calculates attenuation-corrected isotopic mass ratios of specific interest, and provides controls for SGRS hardware as required. This document presents the test plan and report for the data acquisition and analysis software associated with the SGRS system

  11. $\\gamma$-$\\gamma$ and $\\gamma$-p events at high energies

    CERN Document Server

    Schuler, Gerhard A.; Gerhard A Schuler; Torbjorn Sjostrand

    1994-01-01

    A real photon has a complicated nature, whereby it may remain unresolved or fluctuate into a vector meson or a perturbative q-qbar pair. Based on this picture, we previously presented a model for gamma-p events that is based on the presence of three main event classes: direct, VMD and anomalous. In gamma-gamma events, a natural generalization gives three-by-three combinations of the nature of the two incoming photons, and thus six distinct event classes. The properties of these classes are constrained by the choices already made, in the gamma-p model, of cut-off procedures and other aspects. It is therefore possible to predict the energy-dependence of the cross section for each of the six components separately. The total cross section thus obtained is in good agreement with data, and also gives support to the idea that a simple factorized ansatz with a pomeron and a reggeon term can be a good approximation. Event properties undergo a logical evolution from p-p to gamma-p to gamma-gamma events, with larger cha...

  12. New stage in high-energy gamma-ray studies with GAMMA-400 after Fermi-LAT

    Directory of Open Access Journals (Sweden)

    Topchiev N.P.

    2017-01-01

    Full Text Available Fermi-LAT has made a significant contribution to the study of high-energy gamma-ray diffuse emission and the observations of 3000 discrete sources. However, one third of all gamma-ray sources (both galactic and extragalactic are unidentified, the data on the diffuse gamma-ray emission should be clarified, and signatures of dark matter particles in the high-energy gamma-ray range are not observed up to now. GAMMA-400, the currently developing gamma-ray telescope, will have angular (∼0.01∘ at 100 GeV and energy (∼1% at 100 GeV resolutions in the energy range of 10–1000 GeV which are better than Fermi-LAT (as well as ground gamma-ray telescopes by a factor of 5–10. It will observe some regions of the Universe (such as the Galactic Center, Fermi Bubbles, Crab, Cygnus, etc. in a highly elliptic orbit (without shading the telescope by the Earth continuously for a long time. It will allow us to identify many discrete sources, to clarify the structure of extended sources, to specify the data on the diffuse emission, and to resolve gamma rays from dark matter particles.

  13. Burnup determination of power reactor fuel elements by gamma spectrometry; Determination par spectrometrie {gamma} du taux d'irradiation des elements combustibles des reacteurs de puissance

    Energy Technology Data Exchange (ETDEWEB)

    Robin, M; Jastrzeb, M; Boisliveau, S; Boyer, R; Vidal, R [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    This report describes a method for determining by {gamma} spectrometry the burn up and the specific power of fuel elements irradiated in power reactors. The energy spectrum of {gamma} rays emitted by fission products is measured by means of a simple equipment using a sodium iodide detector and a multichannel analyzer. In order to extract from the spectrum a quantity proportional to the burn up, it is necessary to: - isolate an activity specific of one emitter,- give the same importance to fissions in uranium and plutonium - take into account the radioactive decay during and after irradiation. One hundred fuel elements were studied and burn up values obtained by {gamma} spectrometry are compared to results given by chemical analyses. Preliminary measurements show that the accuracy of the results is greatly increased by the use of a germanium detector, due to its good resolution. (authors) [French] Ce rapport expose une methode de determination par spectrometrie {gamma} du taux d'irradiation et de la puissance specifique des elements combustibles irradies dans les reacteurs de puissance. Une installation simple utilisant un detecteur d'iodure de sodium et un selecteur multicanaux mesure le spectre en energie du rayonnement {gamma} emis par les produits de fission. Afin d'extraire du spectre une quantite proportionnelle au taux de combustion, il faut: - isoler une activite specifique a un emetteur, - donner la meme importance aux fissions survenues dans l'uranium et le plutonium, - prendre en compte la decroissance radioactive pendant et apres l'irradiation. Les mesures ont porte sur une centaine d'elements combustibles et les taux de combustion obtenus par spectrometrie {gamma} sont compares aux resultats des analyses chimiques. Des mesures preliminaires montrent que l'utilisation d'un detecteur de germanium augmente considerablement la precision des resultats, en raison de son excellente resolution. (auteurs)

  14. Emergence of White Organic Light-Emitting Diodes Based on Thermally Activated Delayed Fluorescence

    Directory of Open Access Journals (Sweden)

    Peng Xiao

    2018-02-01

    Full Text Available Recently, thermally activated delayed fluorescence (TADF organic light-emitting diodes (OLEDs have attracted both academic and industrial interest due to their extraordinary characteristics, such as high efficiency, low driving voltage, bright luminance, lower power consumption and potentially long lifetime. In this invited review, the fundamental concepts of TADF have been firstly introduced. Then, main approaches to realize WOLEDs based on TADF have been summarized. More specifically, the recent development of WOLEDs based on all TADF emitters, WOLEDs based on TADF and conventional fluorescence emitters, hybrid WOLEDs based on blue TADF and phosphorescence emitters and WOLEDs based on TADF exciplex host and phosphorescence dopants is highlighted. In particular, design strategies, device structures, working mechanisms and electroluminescent processes of the representative WOLEDs based on TADF are reviewed. Finally, challenges and opportunities for further enhancement of the performance of WOLEDs based on TADF are presented.

  15. Automation system for measurement of gamma-ray spectra of induced activity for multi-element high-volume neutron activation analysis at the IBR-2 reactor of FLNP at JINR

    International Nuclear Information System (INIS)

    Pavlov, S.S.; Dmitriev, A.Yu.; Chepurchenko, I.A.; Frontas'eva, M.V.

    2014-01-01

    The automation system for measurement of induced activity of gamma-ray spectra for multi-element high-volume neutron activation analysis (NAA) was designed, developed and implemented at the IBR-2 reactor. The system consists of three devices of automatic sample changers for three Canberra HPGe detector-based gamma spectrometry systems. Each sample changer consists of two-axis linear positioning module M202A by DriveSet (DriveSet.de) company and disk with 45 slots for containers with samples. Control of automatic sample changer is performed by the Xemo S360U controller by Systec (systec.de) company. Positioning accuracy can reach 0.1 mm. Special software performs automatic changing of samples and measurement of gamma spectra at constant interaction with the NAA database. The system is unique and can be recommended for other laboratories as one of the possible ways of the NAA integrated automation

  16. Development of a lion-specific interferon-gamma assay.

    Science.gov (United States)

    Maas, M; van Kooten, P J S; Schreuder, J; Morar, D; Tijhaar, E; Michel, A L; Rutten, V P M G

    2012-10-15

    The ongoing spread of bovine tuberculosis (BTB) in African free-ranging lion populations, for example in the Kruger National Park, raises the need for diagnostic assays for BTB in lions. These, in addition, would be highly relevant for zoological gardens worldwide that want to determine the BTB status of their lions, e.g. for translocations. The present study concerns the development of a lion-specific IFN-γ assay, following the production and characterization of monoclonal antibodies specific for lion interferon-gamma (IFN-γ). Recombinant lion IFN-γ (rLIFN-γ) was produced in mammalian cells and used to immunize mice to establish hybridoma cell lines producing monoclonal antibodies. These were used to develop a sensitive, lion IFN-γ-specific capture ELISA, able to detect rLIFN-γ to the level of 160 pg/ml. Recognition of native lion IFN-γ was shown in an initial assessment of supernatants of mitogen stimulated whole blood cultures of 11 known BTB-negative lions. In conclusion, the capture ELISA shows potential as a diagnostic assay for bovine tuberculosis in lions. Preliminary results also indicate the possible use of the test for other (feline) species. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. The {sup 124}Sb activity standardization by gamma spectrometry for medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, M.C.M. de, E-mail: marcandida@yahoo.com.b [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes, Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear (SEMRA/LNMRI/IRD/CNEN), Av. Salvador Allende s/n, Recreio, Rio de Janeiro, RJ, CEP 22780-160 (Brazil); Iwahara, A.; Delgado, J.U.; Poledna, R.; Silva, R.L. da [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes, Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear (SEMRA/LNMRI/IRD/CNEN), Av. Salvador Allende s/n, Recreio, Rio de Janeiro, RJ, CEP 22780-160 (Brazil)

    2010-07-21

    This work describes a metrological activity determination of {sup 124}Sb, which can be used as radiotracer, applying gamma spectrometry methods with hyper pure germanium detector and efficiency curves. This isotope with good activity and high radionuclidic purity is employed in the form of meglumine antimoniate (Glucantime) or sodium stibogluconate (Pentostam) to treat leishmaniasis. {sup 124}Sb is also applied in animal organ distribution studies to solve some questions in pharmacology. {sup 124}Sb decays by {beta}-emission and it produces several photons (X and gamma rays) with energy varying from 27 to 2700 keV. Efficiency curves to measure point {sup 124}Sb solid sources were obtained from a {sup 166m}Ho standard that is a multi-gamma reference source. These curves depend on radiation energy, sample geometry, photon attenuation, dead time and sample-detector position. Results for activity determination of {sup 124}Sb samples using efficiency curves and a high purity coaxial germanium detector were consistent in different counting geometries. Also uncertainties of about 2% (k=2) were obtained.

  18. Rapid and minimum invasive functional brain mapping by real-time visualization of high gamma activity during awake craniotomy.

    Science.gov (United States)

    Ogawa, Hiroshi; Kamada, Kyousuke; Kapeller, Christoph; Hiroshima, Satoru; Prueckl, Robert; Guger, Christoph

    2014-11-01

    Electrocortical stimulation (ECS) is the gold standard for functional brain mapping during an awake craniotomy. The critical issue is to set aside enough time to identify eloquent cortices by ECS. High gamma activity (HGA) ranging between 80 and 120 Hz on electrocorticogram is assumed to reflect localized cortical processing. In this report, we used real-time HGA mapping and functional neuronavigation integrated with functional magnetic resonance imaging (fMRI) for rapid and reliable identification of motor and language functions. Four patients with intra-axial tumors in their dominant hemisphere underwent preoperative fMRI and lesion resection with an awake craniotomy. All patients showed significant fMRI activation evoked by motor and language tasks. During the craniotomy, we recorded electrocorticogram activity by placing subdural grids directly on the exposed brain surface. Each patient performed motor and language tasks and demonstrated real-time HGA dynamics in hand motor areas and parts of the inferior frontal gyrus. Sensitivity and specificity of HGA mapping were 100% compared with ECS mapping in the frontal lobe, which suggested HGA mapping precisely indicated eloquent cortices. We found different HGA dynamics of language tasks in frontal and temporal regions. Specificities of the motor and language-fMRI did not reach 85%. The results of HGA mapping was mostly consistent with those of ECS mapping, although fMRI tended to overestimate functional areas. This novel technique enables rapid and accurate identification of motor and frontal language areas. Furthermore, real-time HGA mapping sheds light on underlying physiological mechanisms related to human brain functions. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Evaluation of a gamma monitor for survey of waste for shallow land burial

    International Nuclear Information System (INIS)

    Hoy, J.E.

    1978-12-01

    During an 8-month evaluation of the Gamma Waste Monitor, 54 reactor-area scrap casks and 8 shipments from the separations areas containing fission product activities were measured. It was concluded that a more accurate and detailed record of radionuclide burials can be obtained by using this monitor than by present methods of estimation. The monitor will significantly improve records and will provide a more reliable data base for evaluating long-term effects on the environment. Although the monitor can directly detect only gamma-emitting radionuclides, a method is proposed in this report for estimating the total radionuclide distribution by association with radionuclides that are detected. The monitor cannot assay transuranic waste and tritium. In many cases where the radionuclide emits two gamma rays of different energy, corrections for attenuation at other photon energies can be empirically derived from the spectrum. Complete details are included in the Appendix for operating the facility. Experimental data gathered during the evaluation period are contained in the body of this report

  20. Nondestructive and quantitative characterization of TRU and LLW mixed-waste using active and passive gamma-ray spectrometry and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Camp, D.C.; Martz, H.E.

    1991-11-12

    The technology being proposed by LLNL is an Active and Passive Computed Tomography (A P CT) Drum Scanner for contact-handled (CH) wastes. It combines the advantages offered by two well-developed nondestructive assay technologies: gamma-ray spectrometry and computed tomography (CT). Coupled together, these two technologies offer to nondestructively and quantitatively characterize mixed- wastes forms. Gamma-ray spectroscopy uses one or more external radiation detectors to passively and nondestructively measure the energy spectrum emitted from a closed container. From the resulting spectrum one can identify most radioactivities detected, be they transuranic isotopes, mixed-fission products, activation products or environmental radioactivities. Spectral libraries exist at LLNL for all four. Active (A) or transmission CT is a well-developed, nondestructive medical and industrial technique that uses an external-radiation beam to map regions of varying attenuation within a container. Passive (P) or emission CT is a technique mainly developed for medical application, e.g., single-photon emission CT. Nondestructive industrial uses of PCT are under development and just coming into use. This report discuses work on the A P CT Drum Scanner at LLNL.

  1. Investigation of {sup 136} Ba gamma-Transitions in the (n,n` gamma) Reaction

    Energy Technology Data Exchange (ETDEWEB)

    Sergiwa, S M [University of Garyuonis, Benghazi, (Libyan Arab Jamahiriya); Rateb, G M; Zleetni, S M; dufani, M M; Shermit, A M; Al Hamidi, M M [Tajoura Nuclear Research Center, Tripoli, (Libyan Arab Jamahiriya); El-Ahrash, M S [7th of April University, Zawia, (Libyan Arab Jamahiriya)

    1995-10-01

    Using the reactor fast neutron beam, angular distribution and linear polarization of gamma-rays emitted from the {sup 136} Ba (n,n` gamma) reaction were measured. From these measurements, a decay scheme of {sup 1}36{sup B}a has been constructed. New spin and parity (J{pi}) assignments as well as resolving ambiguities in previous assignments for some levels were done. In addition, multipole mixing rations ({delta} - values, important for model comparison) have been unambiguously determined for many gamma-transitions. 1 fig., 2 tabs.

  2. Systematic search for very-high-energy gamma-ray emission from bow shocks of runaway stars

    Science.gov (United States)

    H.E.S.S. Collaboration; Abdalla, H.; Abramowski, A.; Aharonian, F.; Ait Benkhali, F.; Akhperjanian, A. G.; Andersson, T.; Angüner, E. O.; Arakawa, M.; Arrieta, M.; Aubert, P.; Backes, M.; Balzer, A.; Barnard, M.; Becherini, Y.; Becker Tjus, J.; Berge, D.; Bernhard, S.; Bernlöhr, K.; Blackwell, R.; Böttcher, M.; Boisson, C.; Bolmont, J.; Bordas, P.; Bregeon, J.; Brun, F.; Brun, P.; Bryan, M.; Büchele, M.; Bulik, T.; Capasso, M.; Carr, J.; Casanova, S.; Cerruti, M.; Chakraborty, N.; Chalme-Calvet, R.; Chaves, R. C. G.; Chen, A.; Chevalier, J.; Chrétien, M.; Coffaro, M.; Colafrancesco, S.; Cologna, G.; Condon, B.; Conrad, J.; Cui, Y.; Davids, I. D.; Decock, J.; Degrange, B.; Deil, C.; Devin, J.; deWilt, P.; Dirson, L.; Djannati-Ataï, A.; Domainko, W.; Donath, A.; Drury, L. O.'C.; Dutson, K.; Dyks, J.; Edwards, T.; Egberts, K.; Eger, P.; Ernenwein, J.-P.; Eschbach, S.; Farnier, C.; Fegan, S.; Fernandes, M. V.; Fiasson, A.; Fontaine, G.; Förster, A.; Funk, S.; Füßling, M.; Gabici, S.; Gajdus, M.; Gallant, Y. A.; Garrigoux, T.; Giavitto, G.; Giebels, B.; Glicenstein, J. F.; Gottschall, D.; Goyal, A.; Grondin, M.-H.; Hahn, J.; Haupt, M.; Hawkes, J.; Heinzelmann, G.; Henri, G.; Hermann, G.; Hervet, O.; Hinton, J. A.; Hofmann, W.; Hoischen, C.; Holler, M.; Horns, D.; Ivascenko, A.; Iwasaki, H.; Jacholkowska, A.; Jamrozy, M.; Janiak, M.; Jankowsky, D.; Jankowsky, F.; Jingo, M.; Jogler, T.; Jouvin, L.; Jung-Richardt, I.; Kastendieck, M. A.; Katarzyński, K.; Katsuragawa, M.; Katz, U.; Kerszberg, D.; Khangulyan, D.; Khélifi, B.; Kieffer, M.; King, J.; Klepser, S.; Klochkov, D.; Kluźniak, W.; Kolitzus, D.; Komin, Nu.; Kosack, K.; Krakau, S.; Kraus, M.; Krüger, P. P.; Laffon, H.; Lamanna, G.; Lau, J.; Lees, J.-P.; Lefaucheur, J.; Lefranc, V.; Lemière, A.; Lemoine-Goumard, M.; Lenain, J.-P.; Leser, E.; Lohse, T.; Lorentz, M.; Liu, R.; López-Coto, R.; Lypova, I.; Marandon, V.; Marcowith, A.; Mariaud, C.; Marx, R.; Maurin, G.; Maxted, N.; Mayer, M.; Meintjes, P. J.; Meyer, M.; Mitchell, A. M. W.; Moderski, R.; Mohamed, M.; Mohrmann, L.; Morå, K.; Moulin, E.; Murach, T.; Nakashima, S.; de Naurois, M.; Niederwanger, F.; Niemiec, J.; Oakes, L.; O'Brien, P.; Odaka, H.; Öttl, S.; Ohm, S.; Ostrowski, M.; Oya, I.; Padovani, M.; Panter, M.; Parsons, R. D.; Pekeur, N. W.; Pelletier, G.; Perennes, C.; Petrucci, P.-O.; Peyaud, B.; Piel, Q.; Pita, S.; Poon, H.; Prokhorov, D.; Prokoph, H.; Pühlhofer, G.; Punch, M.; Quirrenbach, A.; Raab, S.; Reimer, A.; Reimer, O.; Renaud, M.; de los Reyes, R.; Richter, S.; Rieger, F.; Romoli, C.; Rowell, G.; Rudak, B.; Rulten, C. B.; Sahakian, V.; Saito, S.; Salek, D.; Sanchez, D. A.; Santangelo, A.; Sasaki, M.; Schlickeiser, R.; Schüssler, F.; Schulz, A.; Schwanke, U.; Schwemmer, S.; Seglar-Arroyo, M.; Settimo, M.; Seyffert, A. S.; Shafi, N.; Shilon, I.; Simoni, R.; Sol, H.; Spanier, F.; Spengler, G.; Spies, F.; Stawarz, Ł.; Steenkamp, R.; Stegmann, C.; Stycz, K.; Sushch, I.; Takahashi, T.; Tavernet, J.-P.; Tavernier, T.; Taylor, A. M.; Terrier, R.; Tibaldo, L.; Tiziani, D.; Tluczykont, M.; Trichard, C.; Tsuji, N.; Tuffs, R.; Uchiyama, Y.; van der Walt, D. J.; van Eldik, C.; van Rensburg, C.; van Soelen, B.; Vasileiadis, G.; Veh, J.; Venter, C.; Viana, A.; Vincent, P.; Vink, J.; Voisin, F.; Völk, H. J.; Vuillaume, T.; Wadiasingh, Z.; Wagner, S. J.; Wagner, P.; Wagner, R. M.; White, R.; Wierzcholska, A.; Willmann, P.; Wörnlein, A.; Wouters, D.; Yang, R.; Zabalza, V.; Zaborov, D.; Zacharias, M.; Zanin, R.; Zdziarski, A. A.; Zech, A.; Zefi, F.; Ziegler, A.; Żywucka, N.

    2018-04-01

    Context. Runaway stars form bow shocks by ploughing through the interstellar medium at supersonic speeds and are promising sources of non-thermal emission of photons. One of these objects has been found to emit non-thermal radiation in the radio band. This triggered the development of theoretical models predicting non-thermal photons from radio up to very-high-energy (VHE, E ≥ 0.1 TeV) gamma rays. Subsequently, one bow shock was also detected in X-ray observations. However, the data did not allow discrimination between a hot thermal and a non-thermal origin. Further observations of different candidates at X-ray energies showed no evidence for emission at the position of the bow shocks either. A systematic search in the Fermi-LAT energy regime resulted in flux upper limits for 27 candidates listed in the E-BOSS catalogue. Aim. Here we perform the first systematic search for VHE gamma-ray emission from bow shocks of runaway stars. Methods: Using all available archival H.E.S.S. data we search for very-high-energy gamma-ray emission at the positions of bow shock candidates listed in the second E-BOSS catalogue release. Out of the 73 bow shock candidates in this catalogue, 32 have been observed with H.E.S.S. Results: None of the observed 32 bow shock candidates in this population study show significant emission in the H.E.S.S. energy range. Therefore, flux upper limits are calculated in five energy bins and the fraction of the kinetic wind power that is converted into VHE gamma rays is constrained. Conclusions: Emission from stellar bow shocks is not detected in the energy range between 0.14 and 18 TeV.The resulting upper limits constrain the level of VHE gamma-ray emission from these objects down to 0.1-1% of the kinetic wind energy.

  3. Neutron-induced gamma-ray spectroscopy: simulations for chemical mapping of planetary surfaces

    International Nuclear Information System (INIS)

    Brueckner, J.; Waenke, H.; Reedy, R.C.

    1986-01-01

    Cosmic rays interact with the surface of a planetary body and produce a cascade of secondary particles, such as neutrons. Neutron-induced scattering and capture reactions play an important role in the production of discrete gamma-ray lines that can be measured by a gamma-ray spectrometer on board of an orbiting spacecraft. These data can be used to determine the concentration of many elements in the surface of a planetary body, which provides clues to its bulk composition and in turn to its origin and evolution. To investigate the gamma rays made by neutron interactions, thin targets were irradiated with neutrons having energies from 14 MeV to 0.025 eV. By means of foil activation technique the ratio of epithermal to thermal neutrons was determined to be similar to that in the Moon. Gamma rays emitted by the targets and the surrounding material were detected by a high-resolution germanium detector in the energy range of 0.1 to 8 MeV. Most of the gamma-ray lines that are expected to be used for planetary gamma-ray spectroscopy were found in the recorded spectra and the principal lines in these spectra are presented. 58 refs., 7 figs., 9 tabs

  4. A study of Venus surface elemental composition from 14 MeV neutron induced gamma ray spectroscopy: Activation analysis

    International Nuclear Information System (INIS)

    Jun, I.; Kim, W.; Smith, M.; Mitrofanov, I.; Litvak, M.

    2011-01-01

    The surface elemental composition of Venus can be determined using an artificially pulsed 14 MeV neutron generator (PNG) combined with a gamma ray spectrometer (GRS). The 14 MeV neutrons will interact with the surface materials and generate gamma rays, characteristic of specific elements, whose energy spectrum will be measured by GRS. These characteristic gamma rays are produced mainly through 3 different neutron interaction mechanisms: capture, inelastic, and activation reactions. Each reaction type has a different neutron energy dependency and different time scale for gamma ray production and transport. Certain elements are more easily identified through one reaction type over the others. Thus, careful analysis of the gamma ray spectra during and after the neutron pulse provides a comprehensive understanding of the surface elemental composition. In this paper, we use a well-tested neutron/gamma transport code, called Monte Carlo N-Particles (MCNP), to investigate the measurement capability of a PNG-GRS detection system through the neutron activation reactions. An activation analysis was performed for a representative soil composition of Venus with a notional operational scenario of PNG and GRS. The analysis shows that the proposed instrument concept can identify most of the modeled surface elements at Venus with sufficient accuracy through the activation mode. Specifically, U, Th, K, Si can be measured to within 1%, Fe within 2%, Al within 10%, Ca within 5%, Mg with 15%, Mn with 20%, and Cl within 6%. Although modeled in the analysis, it is shown that the activation mode alone cannot distinguish the S and Ti peaks.

  5. The adipogenic acetyltransferase Tip60 targets activation function 1 of peroxisome proliferator-activated receptor gamma

    DEFF Research Database (Denmark)

    van Beekum, Olivier; Brenkman, Arjan B; Grøntved, Lars

    2008-01-01

    The transcription factor peroxisome proliferator-activated receptor gamma (PPARgamma) plays a key role in the regulation of lipid and glucose metabolism in adipocytes, by regulating their differentiation, maintenance, and function. The transcriptional activity of PPARgamma is dictated by the set...... in cells, and through use of chimeric proteins, we established that coactivation by Tip60 critically depends on the N-terminal activation function 1 of PPARgamma, a domain involved in isotype-specific gene expression and adipogenesis. Chromatin immunoprecipitation experiments showed that the endogenous Tip...... of proteins with which this nuclear receptor interacts under specific conditions. Here we identify the HIV-1 Tat-interacting protein 60 (Tip60) as a novel positive regulator of PPARgamma transcriptional activity. Using tandem mass spectrometry, we found that PPARgamma and the acetyltransferase Tip60 interact...

  6. Active neutron and gamma-ray imaging of highly enriched uranium for treaty verification.

    Science.gov (United States)

    Hamel, Michael C; Polack, J Kyle; Ruch, Marc L; Marcath, Matthew J; Clarke, Shaun D; Pozzi, Sara A

    2017-08-11

    The detection and characterization of highly enriched uranium (HEU) presents a large challenge in the non-proliferation field. HEU has a low neutron emission rate and most gamma rays are low energy and easily shielded. To address this challenge, an instrument known as the dual-particle imager (DPI) was used with a portable deuterium-tritium (DT) neutron generator to detect neutrons and gamma rays from induced fission in HEU. We evaluated system response using a 13.7-kg HEU sphere in several configurations with no moderation, high-density polyethylene (HDPE) moderation, and tungsten moderation. A hollow tungsten sphere was interrogated to evaluate the response to a possible hoax item. First, localization capabilities were demonstrated by reconstructing neutron and gamma-ray images. Once localized, additional properties such as fast neutron energy spectra and time-dependent neutron count rates were attributed to the items. For the interrogated configurations containing HEU, the reconstructed neutron spectra resembled Watt spectra, which gave confidence that the interrogated items were undergoing induced fission. The time-dependent neutron count rate was also compared for each configuration and shown to be dependent on the neutron multiplication of the item. This result showed that the DPI is a viable tool for localizing and confirming fissile mass and multiplication.

  7. A weighted least-squares lump correction algorithm for transmission-corrected gamma-ray nondestructive assay

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Sprinkle, J.K. Jr.; Sheppard, G.A.

    1993-01-01

    With transmission-corrected gamma-ray nondestructive assay instruments such as the Segmented Gamma Scanner (SGS) and the Tomographic Gamma Scanner (TGS) that is currently under development at Los Alamos National Laboratory, the amount of gamma-ray emitting material can be underestimated for samples in which the emitting material consists of particles or lumps of highly attenuating material. This problem is encountered in the assay of uranium and plutonium-bearing samples. To correct for this source of bias, we have developed a least-squares algorithm that uses transmission-corrected assay results for several emitted energies and a weighting function to account for statistical uncertainties in the assay results. The variation of effective lump size in the fitted model is parameterized; this allows the correction to be performed for a wide range of lump-size distributions. It may be possible to use the reduced chi-squared value obtained in the fit to identify samples in which assay assumptions have been violated. We found that the algorithm significantly reduced bias in simulated assays and improved SGS assay results for plutonium-bearing samples. Further testing will be conducted with the TGS, which is expected to be less susceptible than the SGS to systematic source of bias

  8. In vivo adenylate cyclase activity in ultraviolet- and gamma-irradiated Escherichia coli

    Energy Technology Data Exchange (ETDEWEB)

    Chatterjee, A; Bhattacharya, A K

    1988-06-01

    The incorporation of (/sup 14/C)adenine into the cyclic AMP fraction by whole cells of Escherichia coli B/r was taken as a measure of the in vivo adenylate cyclase activity. This activity was significantly inhibited by irradiation of the cells either with /sup 60/Co ..gamma..-rays or with UV light from a germicidal lamp, suggesting inhibition of cyclic AMP synthesis. The incubation of cells after irradiation with lower doses (50-100 Gy) of ..gamma..-rays produced a significant increase of in vivo adenylate cyclase activity, whereas there was no significant change after high doses (150 Gy and above). Dark incubation of cells after irradiation with UV light (54 J m/sup -2/) led to recovery of enzyme activity to the level measured in unirradiated cells. Thus it appears that the catabolite repression of L-arabinose isomerase induced by UV light, as well as ..gamma..-irradiation, is due to reduced cyclic AMP synthesis in irradiated cells.

  9. Non-destructive assay of mechanical components using gamma-rays and thermal neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Erica Silvani; Avelino, Mila R. [PPG-EM/UERJ, R. Sao Francisco Xavier, 524, Maracana - Rio de Janeiro - RJ (Brazil); Almeida, Gevaldo L. de; Souza, Maria Ines S. [IEN/CNEN, Rua Helio de Almeida, 75, Ilha do Fundao, Rio de Janeiro - RJ (Brazil)

    2013-05-06

    This work presents the results obtained in the inspection of several mechanical components through neutron and gamma-ray transmission radiography. The 4.46 Multiplication-Sign 10{sup 5} n.cm{sup -2}.s{sup -1} thermal neutron flux available at the main port of the Argonauta research reactor in Instituto de Engenharia Nuclear has been used as source for the neutron radiographic imaging. The 412 keV {gamma}-ray emitted by {sup 198}Au, also produced in that reactor, has been used as interrogation agent for the gamma radiography. Imaging Plates - IP specifically designed to operate with thermal neutrons or with X-rays have been employed as detectors and storage devices for each of these radiations.

  10. Bidirectional modulation of hippocampal gamma (20-80 Hz) frequency activity in vitro via alpha(α)- and beta(β)-adrenergic receptors (AR).

    Science.gov (United States)

    Haggerty, D C; Glykos, V; Adams, N E; Lebeau, F E N

    2013-12-03

    Noradrenaline (NA) in the hippocampus plays an important role in memory function and has been shown to modulate different forms of synaptic plasticity. Oscillations in the gamma frequency (20-80 Hz) band in the hippocampus have also been proposed to play an important role in memory functions and, evidence from both in vitro and in vivo studies, has suggested this activity can be modulated by NA. However, the role of different NA receptor subtypes in the modulation of gamma frequency activity has not been fully elucidated. We have found that NA (30 μM) exerts a bidirectional control on the magnitude of kainate-evoked (50-200 nM) gamma frequency oscillations in the cornu Ammonis (CA3) region of the rat hippocampus in vitro via activation of different receptor subtypes. Activation of alpha-adrenergic receptors (α-AR) reduced the power of the gamma frequency oscillation. In contrast, activation of beta-adrenergic receptors (β-AR) caused an increase in the power of the gamma frequency oscillations. Using specific agonists and antagonists of AR receptor subtypes we demonstrated that these effects are mediated specifically via α1A-AR and β1-AR subtypes. NA activated both receptor subtypes, but the α1A-AR-mediated effect predominated, resulting in a reversible suppression of gamma frequency activity. These results suggest that NA is able to differentially modulate on-going gamma frequency oscillatory activity that could result in either increased or decreased information flow through the hippocampus. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.

  11. Laboratory of High resolution gamma spectrometry

    International Nuclear Information System (INIS)

    Mendez G, A.; Giber F, J.; Rivas C, I.; Reyes A, B.

    1992-01-01

    The Department of Nuclear Experimentation of the Nuclear Systems Management requests the collaboration of the Engineering unit for the supervision of the execution of the work of the High resolution Gamma spectrometry and low bottom laboratory, using the hut of the sub critic reactor of the Nuclear Center of Mexico. This laboratory has the purpose of determining the activity of special materials irradiated in nuclear power plants. In this report the architecture development, concepts, materials and diagrams for the realization of this type of work are presented. (Author)

  12. Highly efficient silicon light emitting diode

    NARCIS (Netherlands)

    Le Minh, P.; Holleman, J.; Wallinga, Hans

    2002-01-01

    In this paper, we describe the fabrication, using standard silicon processing techniques, of silicon light-emitting diodes (LED) that efficiently emit photons with energy around the silicon bandgap. The improved efficiency had been explained by the spatial confinement of charge carriers due to a

  13. Scintillation {gamma} spectrography. Physical principles. Apparatus. Operation; Spectrographie {gamma} a scintillations. Principes physiques. Appareillage. Utilisation

    Energy Technology Data Exchange (ETDEWEB)

    Julliot, C. [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The scintillation detector forms the main part of the instrument used, the electronic unit presenting the results produced. After a brief description of the process of {gamma} photon absorption in the material, the particular case of NaI (T1), the scintillator used, is examined. The intensity of the scintillation caused by {gamma} ray absorption and the characteristics of the photomultiplier play a determining part in the energy resolution of the instrument. For the {gamma} recording spectrograph, we show to what extent the technique for using the electronic unit can modify the results. A detailed description is given of the activity measurement of a {gamma}-emitting radioelement by the spectrographic method. (author) [French] Dans l'appareillage utilise, le detecteur a scintillations constitue la piece maitresse, l'ensemble electronique presente les resultats issus du detecteur. Apres avoir brievement decrit le processus d'absorption des photons {gamma} dans la matiere, nous examinons le cas particulier du NaI(T1), le scintillateur utilise. L'intensite de la scintillation provoque par l'absorption des rayons {gamma} et les caracteristiques du photomultiplicateur jouent un role determinant dans la resolution en energie de l'appareil. Pour le spectrographe {gamma} enregistreur, nous indiquons dans quelle mesure la technique d'utilisation de l'ensemble electronique peut modifier les resultats. La-mesure de l'activite d'un radioelement emetteur {gamma} par spectrographie fait l'objet d'une description detaillee. (auteur)

  14. Scintillation {gamma} spectrography. Physical principles. Apparatus. Operation; Spectrographie {gamma} a scintillations. Principes physiques. Appareillage. Utilisation

    Energy Technology Data Exchange (ETDEWEB)

    Julliot, C [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The scintillation detector forms the main part of the instrument used, the electronic unit presenting the results produced. After a brief description of the process of {gamma} photon absorption in the material, the particular case of NaI (T1), the scintillator used, is examined. The intensity of the scintillation caused by {gamma} ray absorption and the characteristics of the photomultiplier play a determining part in the energy resolution of the instrument. For the {gamma} recording spectrograph, we show to what extent the technique for using the electronic unit can modify the results. A detailed description is given of the activity measurement of a {gamma}-emitting radioelement by the spectrographic method. (author) [French] Dans l'appareillage utilise, le detecteur a scintillations constitue la piece maitresse, l'ensemble electronique presente les resultats issus du detecteur. Apres avoir brievement decrit le processus d'absorption des photons {gamma} dans la matiere, nous examinons le cas particulier du NaI(T1), le scintillateur utilise. L'intensite de la scintillation provoque par l'absorption des rayons {gamma} et les caracteristiques du photomultiplicateur jouent un role determinant dans la resolution en energie de l'appareil. Pour le spectrographe {gamma} enregistreur, nous indiquons dans quelle mesure la technique d'utilisation de l'ensemble electronique peut modifier les resultats. La-mesure de l'activite d'un radioelement emetteur {gamma} par spectrographie fait l'objet d'une description detaillee. (auteur)

  15. Analysis and Summary Report of Historical Dry Well Gamma Logs for the 241-B Tank Farm - 200 East

    International Nuclear Information System (INIS)

    SYDNOR, H.A.

    2000-01-01

    This report provides a summary of the gross gamma ray data for the 241-B Tank Farm and is intended to identify changes in the gamma activity of gamma-emitting radionuclide contaminants around each accessible borehole, and is not intended to provide interpretation of the data relative to vadose zone mechanics. Trends in data, as well as areas where additional information would be helpful in evaluating the unusual nature of some of the data, are discussed

  16. High rate gamma spectroscopy system for activation analysis of short-lived isomeric transitions

    Energy Technology Data Exchange (ETDEWEB)

    Westphall, G P [Atominstitut der Oesterreichischen Hochschulen, Vienna

    1976-07-15

    A high rate spectroscopy system specially suited for measurement of short-lived isomeric transitions is described, which, as part of a fast activation analysis facility at the TRIGA Mark II reactor, provides for automatic recording and immediate evaluation of gamma spectra taken from nuclides activated at stationary or pulsed reactor power. The system consists of a commercial de-coupled Ge(Li)-detector of 70 cm/sup 3/ modified for recycling operation for input rates in excess of 500000 c/s /sup 60/Co, a time variant trapezoidal shaping section and a fast constant dead-time ADC coupled to a programmed multichannel analyzer. Novel circuits for efficient pile-up rejection and time variant base line restoration extend the concept of gated integration up to count rates of more than 200000 c/s /sup 60/Co. Time-sequenced recording of spectra is performed by a minicomputer operated as a front-end processor of a larger laboratory computer, where final data processing takes place. New concepts for very simple and cost-effective implementation of multichannel analyzers by means of general purpose small computers are described.

  17. Superantigen and HLA-DR ligation induce phospholipase-C gamma 1 activation in class II+ T cells

    DEFF Research Database (Denmark)

    Kanner, S B; Odum, Niels; Grosmaire, L

    1992-01-01

    Bacterial enterotoxin superantigens bind directly to HLA class II molecules (HLA-DR) expressed on both APC and activated human T cells, and simultaneously bind to certain V beta chains of the TCR. In this report, we compared early T cell signaling events in human alloantigen-stimulated T cells when...... activated by HLA-DR ligation through antibody cross-linking or by direct enterotoxin superantigen binding. Both types of stimuli induced tyrosine phosphorylation of phosphatidylinositol-specific phospholipase C gamma 1 (PLC gamma 1) and an increase in intracellular calcium concentration; however......, superantigen-induced signaling was stronger than class II ligation alone. Antibody-mediated ligation of HLA-DR with CD3 resulted in augmented PLC gamma 1 activation and increased calcium mobilization, consistent with a mechanism of superantigen activity through a combination of class II and CD3/Ti signals...

  18. Prompt gamma-based neutron dosimetry for Am-Be and other workplace neutron spectra

    International Nuclear Information System (INIS)

    Udupi, Ashwini; Panikkath, Priyada; Sarkar, P.K.

    2016-01-01

    A new field-deployable technique for estimating the neutron ambient dose equivalent H*(10) by using the measured prompt gamma intensities emitted from borated high-density polyethylene (BHDPE) and the combination of normal HDPE and BHDPE with different configurations have been evaluated in this work. Monte Carlo simulations using the FLUKA code has been employed to calculate the responses from the prompt gammas emitted due to the monoenergetic neutrons interacting with boron, hydrogen, and carbon nuclei. A suitable linear combination of these prompt gamma responses (dose conversion coefficient (DCC)-estimated) is generated to approximate the International Commission on Radiological Protection provided DCC using the cross-entropy minimization technique. In addition, the shape and configurations of the HDPE and BHDPE combined system are optimized using the FLUKA code simulation results. The proposed method is validated experimentally, as well as theoretically, using different workplace neutron spectra with a satisfactory outcome. (author)

  19. Developing Procedures for Screening High Emitting Vehicles and Quantifying the Environmental Impacts of Grades

    OpenAIRE

    Park, Sangjun

    2005-01-01

    Since the transportation sector is highly responsible for U.S. fuel consumption and emissions, assessing the environmental impacts of transportation activities is essential for air-quality improvement programs. Also, high emitting vehicles need to be considered in the modeling of mobile-source emissions, because they contribute to a large portion of the total emissions, although they comprise a small portion of the vehicle fleet. In the context of this research, the thesis quantifies the envi...

  20. Improvements on Low Level Activity Gamma Measurements and X-ray Spectrometry at the CEA-MADERE Measurement Platform

    OpenAIRE

    Sergeyeva Victoria; Domergue Christophe; Destouches Christophe; Girard Jean Michel; Philibert Hervé; Bonora Jonathan; Thiollay Nicolas; Lyoussi Abdallah

    2016-01-01

    The CEA MADERE platform (Measurement Applied to DosimEtry in REactors) is a part of the Instrumentation Sensors and Dosimetry Laboratory (LDCI). This facility is dedicated to the specific activity measurements of solid and radioactive samples using Gamma and X-ray spectrometry. MADERE is a high-performance facility devoted to neutron dosimetry for experimental programs performed in CEA and for the irradiation surveillance programmes of PWR vessels. The MADERE platform is engaged in a continuo...

  1. Sodium fast reactor power monitoring using gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Coulon, R.; Normand, S.; Barbot, L.; Domenech, T.; Kondrasovs, V.; Corre, G.; Frelin, A.M. [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, CEA - Saclay DRT/LIST/DETECS/SSTM, Batiment 516 - P.C. no 72, Gif sur Yvette, F-91191 (France); Montagu, T.; Dautremer, T.; Barat, E. [CEA, LIST, Laboratoire Processus Stochastiques et Spectres (France); Ban, G. [ENSICAEN (France)

    2009-06-15

    This work deals with the use of high flux gamma spectrometry to monitor the fourth generation of sodium fast reactor (SFR) power. The simulation study part of this work has shown that power monitoring in a short time response and with a good accuracy is possible. An experimental test is under preparation at the French SFR Phenix experimental reactor to validate simulation studies. First, physical calculations have been done to correlate gamma activity to the released thermal power. Gamma emitter production rate in the reactor core was calculated with technical and nuclear data as the sodium velocity, the atomic densities, Phenix neutron spectrum and incident neutron cross-sections of reactions producing gamma emitters. A thermal hydraulic transfer function was used for modeling primary sodium flow in our calculations. For the power monitoring problematic, use of a short decay period gamma emitter will allow to have a very fast response system without cumulative effect. We have determined that the best tagging agent is 20F which emits 1634 keV energy photons with a decay period of 11 s. The gamma spectrum was determined by flux point and a pulse high tally MCNP5.1.40 simulation and shown the possibility to measure the signal of this radionuclide. The experiment will be set during the reactor 'end life testing'. The Delayed Neutron Detection (DND) room has been chosen as the best available location on Phenix reactor to measure this kind of radionuclide due to a short transit time from reactor core to measurement sample. This location is optimum for global power measurement because homogenized sampling in the reactor hot pool. The main spectrometer is composed of a coaxial high purity germanium diode (HPGe) coupled with a transistor reset preamplifier. The HPGe diode signal will be processed by the Adonis digital signal processing due to high flux and fast activity measurement. Post-processing softwares will be used to limit statistical problems of the

  2. Enhanced Gamma Oscillatory Activity in Rats with Chronic Inflammatory Pain

    OpenAIRE

    Wang, Jing; Wang, Jing; Xing, Guo-Gang; Li, Xiaoli; Wan, You

    2016-01-01

    It has been reported that oscillatory gamma activity participates in brief acute pain and tonic ongoing pain. It is of great interest to determine whether the gamma activity is involved in chronic pain since chronic pain is a more severe pathological condition characterized by pain persistency. To investigate the oscillatory gamma activity in chronic pain, in the present study, we recorded spontaneous electrocorticogram (ECoG) signals during chronic pain development in rats with chronic infla...

  3. Design of a {gamma}-ray analysis system for determination of boron in a patient`s head, during neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Verbakel, W.F.A.R.

    1997-12-01

    Boron Neutron Capture Therapy (BNCT) is a new radiation therapy in which thermal neutron capture by {sup 10}B is used for the selective destruction of a cancer tumour. At the High Flux Reactor (HFR) in Petten, Netherlands, a therapy facility is built for the neutron irradiations. In first instance, patients with a brain tumour will be treated. The doses delivered to the tumour and to the healthy tissue depend on the thermal neutron fluence and on the boron concentrations in these regions. Yet, both concentrations change in time after the administration of the tumour-seeking boron compound. An accurate determination of the patient`s dose requires the knowledge of these time dependent concentrations during the therapy. For this reason, a {gamma}-ray telescope system, together with a reconstruction tool, are developed. Two HPGe-detectors measure the 478 keV prompt {gamma}-rays which are emitted at the boron neutron capture reaction, in a large background of {gamma}-rays and neutrons. By using the detectors in a telescope configuration, only {gamma}-rays emitted by a small specific region are detected. The best shielding of the detectors is obtained by performing the measurements through a small hole in the iron roof. A reconstruction tool is developed to calculate absolute boron concentrations using the measured boron {gamma}-ray detection rates. Besides the boron {gamma}-rays, a large component of 2.2 MeV {gamma}-rays emitted at thermal neutron capture in hydrogen is measured. Since the hydrogen distribution is almost homogeneous over the head, this component can serve as a measure of the total number of thermal neutrons in the observed volume. By using the hydrogen {gamma}-line for normalisation of the boron concentration, the reconstruction tool eliminates the greater part of the influence of the inhomogeneity of the thermal neutron distribution. MCNP calculations are used as a tool for the optimisation of the detector configuration. Experiments on a head phantom

  4. On the radiochemical purity of elementary 35S with high specific activity

    International Nuclear Information System (INIS)

    Todorovsky, D.S.; Kostadinov, K.N.; Efremova, Yu.N.

    1979-01-01

    Radiochemical composition and chemical changes with increasing storage time of benzene solutions and of solid species of elementary 35 S with high specific activity are studied. The dependence of the stability on the specific activity and the radioactive concentration is shown and some tentative limits are given for permissible storage periods. (author)

  5. CeBr3 as a room-temperature, high-resolution gamma-ray detector

    International Nuclear Information System (INIS)

    Guss, Paul; Reed, Michael; Yuan Ding; Reed, Alexis; Mukhopadhyay, Sanjoy

    2009-01-01

    Cerium bromide (CeBr 3 ) has become a material of interest in the race for high-resolution gamma-ray spectroscopy at room temperature. This investigation quantified the potential of CeBr 3 as a room-temperature, high-resolution gamma-ray detector. The performance of CeBr 3 crystals was compared to other scintillation crystals of similar dimensions and detection environments. Comparison of self-activity of CeBr 3 to cerium-doped lanthanum tribromide (LaBr 3 :Ce) was performed. Energy resolution and relative intrinsic efficiency were measured and are presented.

  6. A study on gamma rays from electrochemical cells

    International Nuclear Information System (INIS)

    Shin, Seung Ai

    1993-01-01

    The energies and intensities of gamma rays emitted from 3 cells with Pd-cathodes of φ 1mm x 10mm, φ 2mm x 20mm, φ 1mm x 10mm were determined using HPGe-detector system and compared with Pd-neutron capture model. Very strong gamma rays of 512keC, 622keC, 1051keC and 8 more important ones were found to be identical with characteristic gamma rays of 106 Pd and 109 Pd. It is likely that the neutron capture reaction, A PD(n, γ) A+1 Pd, occurred in the cell and the neutrons came from the fusion reaction of two deutrons. It is necessary, however, to retest the model since another strong 84keV-gamma rays do not belong to any A+1 Pd-gamma spectra and two important 106 Pd-gamma rays 717keV, 1046KeV were not detected. Total amount of emitted gamma rays was large when the size of the Pd-cathod was large. Its depedence on the time of measurement and the preheating period did not have any regularities. Thus the replication is not an easy thing. (Author)

  7. Fc gamma receptor activation induces the tyrosine phosphorylation of both phospholipase C (PLC)-gamma 1 and PLC-gamma 2 in natural killer cells

    OpenAIRE

    1992-01-01

    Crosslinking of the low affinity immunoglobulin G (IgG) Fc receptor (Fc gamma R type III) on natural killer (NK) cells initiates antibody- dependent cellular cytotoxicity. During this process, Fc gamma R stimulation results in the rapid activation of phospholipase C (PLC), which hydrolyzes membrane phosphoinositides, generating inositol-1,4,5- trisphosphate and sn-1,2-diacylglycerol as second messengers. We have recently reported that PLC activation after Fc gamma R stimulation can be inhibit...

  8. Airborne and total gamma absorbed dose rates at Patiala - India

    International Nuclear Information System (INIS)

    Tesfaye, Tilahun; Sahota, H.S.; Singh, K.

    1999-01-01

    The external gamma absorbed dose rate due to gamma rays originating from gamma emitting aerosols in air, is compared with the total external gamma absorbed dose rate at the Physics Department of Punjabi University, Patiala. It has been found out that the contribution, to the total external gamma absorbed dose rate, of radionuclides on particulate matter suspended in air is about 20% of the overall gamma absorbed dose rate. (author)

  9. Reconstruction of the isotope activity content of heterogeneous nuclear waste drums.

    Science.gov (United States)

    Krings, Thomas; Mauerhofer, Eric

    2012-07-01

    Radioactive waste must be characterized in order to verify its conformance with national regulations for intermediate storage or its disposal. Segmented gamma scanning (SGS) is a most widely applied non-destructive analytical technique for the characterization of radioactive waste drums. The isotope specific activity content is generally calculated assuming a homogeneous matrix and activity distribution for each measured drum segment. However, real radioactive waste drums exhibit non-uniform isotope and density distributions most affecting the reliability and accuracy of activities reconstruction in SGS. The presence of internal shielding structures in the waste drum contributes generally to a strong underestimation of the activity and this in particular for radioactive sources emitting low energy gamma-rays independently of their spatial distribution. In this work we present an improved method to quantify the activity of spatially concentrated gamma-emitting isotopes (point sources or hot spots) in heterogeneous waste drums with internal shielding structures. The isotope activity is reconstructed by numerical simulations and fits of the angular dependent count rate distribution recorded during the drum rotation in SGS using an analytical expression derived from a geometric model. First results of the improved method and enhancements of this method are shown and are compared to each other as well as to the conventional method which assumes a homogeneous matrix and activity distribution. It is shown that the new model improves the accuracy and the reliability of the activity reconstruction in SGS and that the presented algorithm is suitable with respect to the framework requirement of industrial application. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Standard test method for nondestructive assay of special nuclear material in low density scrap and waste by segmented passive gamma-Ray scanning

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the transmission-corrected nondestructive assay (NDA) of gamma-ray emitting special nuclear materials (SNMs), most commonly 235U, 239Pu, and 241Am, in low-density scrap or waste, packaged in cylindrical containers. The method can also be applied to NDA of other gamma-emitting nuclides including fission products. High-resolution gamma-ray spectroscopy is used to detect and measure the nuclides of interest and to measure and correct for gamma-ray attenuation in a series of horizontal segments (collimated gamma detector views) of the container. Corrections are also made for counting losses occasioned by signal processing limitations (1-3). 1.2 There are currently several systems in use or under development for determining the attenuation corrections for NDA of radioisotopic materials (4-8). A related technique, tomographic gamma-ray scanning (TGS), is not included in this test method (9, 10, 11). 1.2.1 This test method will cover two implementations of the Segmented Gamma Scanning ...

  11. Production and Applications of Long-Lived Positron-Emitting Radionuclides

    Science.gov (United States)

    Graves, Stephen A.

    Positron emission tomography (PET) is a medical imaging modality capable of determining the in vivo spatial distribution of a biologically relevant molecule which has been labeled with a positron-emitting isotope. The use of molecules such as monoclonal antibodies and nanoparticles for therapeutic and diagnostic applications has expanded preclinically in recent years. As these larger molecules tend to have longer circulation times and slow clearance kinetics, positron-emitting isotopes with half-lives longer than conventional medical radioisotopes are required for PET applications. This dissertation details methods for the production of 51Mn (t1/2: 45.4 min), 52gMn (t1/2: 5.59 d), 64Cu (t1/2: 12.7 h), 76Br (t1/2: 16.2 h), 89Zr (t1/2: 3.27 d), and 194Au (t1/2: 38.0 h) on low-energy medical cyclotrons, including targetry considerations, radiochemical separation methods, and analysis of resulting purity. Pursuant to the production of these isotopes, several instrumentation developments have been made including implementation of an automatic nuclide identification library for gamma spectroscopy; development of methods for dead time correction and background estimation in auto-gamma counting; and the creation of a new linearly-filled Derenzo-type PET phantom. Measurement of the radioactive half-lives of 51Mn and 52gMn are presented in addition to their use in a variety of preclinical molecular imaging applications, including immunoPET, stem cell tracking, functional beta-cell mass determination, and probing the impact of isoflurane on acute pancreatic function. An analytic model of effective specific activity is formed and tested against preliminary trace metal analysis results. Measurements of excitation functions for the large-scale production of medically relevant isotopes, including 52gMn, at the Los Alamos National Laboratory Isotope Production Facility (100 MeV p+) are presented. The results described herein have enabled and informed a variety of novel

  12. In vivo prompt gamma activation analysis facility for total body nitrogen and cadmium

    International Nuclear Information System (INIS)

    Munive, Marco; Solis, Jose; Revilla, Angel

    2008-01-01

    Full text: Prompt Neutron Activation Analysis (PGNAA) is a technique that could have medical applications, like determination of body's contents of protein and heavy metals in vivo. The in vivo PGNAA facility, contains a neutron source (Cf-252) with safety device, a compartment for animal irradiation, and a gamma rays detecting system based on the NaI(Tl) detector with an analytical software. The prompt gamma rays were emitted after 10 -15 s of the interaction, so they don't produce radioactive waste, and have a characteristics energy for each element, i.e. a strong peak at 2.24 MeV is observed for H. The facility has been used with laboratory mice. Water-filled phantom placed in the neutron beam was used to system calibration. Three study groups of 5 mice each one were selected and were feed with a different diet and the total body nitrogen (TBN) of the mice was monitored with the facility. The diet produced a different TBN for each group. Some mice drunk diluted water with Cl 2 Cd, so the presence of Cd was detected in the mouse. The minimum Cd concentration that the system can detect was 20 ppm. The total dose (neutron and gamma dose was measured from TLDs and simulated by MNCP-4B in the sample compartment during the irradiation time (5 minutes) is less than 2.5 mSv. This total dose is low than the dose from other analytical radiological techniques (25 a 50 mSv). (author)

  13. Topical Rosiglitazone Treatment Improves Ulcerative Colitis by Restoring Peroxisome Proliferator-Activated Receptor-gamma Activity

    DEFF Research Database (Denmark)

    Pedersen, G.; Brynskov, Jørn

    2010-01-01

    and functional activity in human colonic epithelium and explored the potential of topical treatment with rosiglitazone (a PPAR gamma ligand) in patients with ulcerative colitis. METHODS: Spontaneous and rosiglitazone-mediated PPAR gamma and adipophillin expression (a gene transcriptionally activated by PPAR...... for 14 days. RESULTS: PPAR gamma expression was fourfold reduced in epithelial cells from inflamed compared with uninflamed mucosa and controls. Adipophillin levels were decreased in parallel. Rosiglitazone induced a concentration-dependent increase in adipophillin levels and restored PPAR gamma activity...... in epithelial cells from inflamed mucosa in vitro. Rosiglitazone enema treatment was well tolerated and reduced the Mayo ulcerative colitis score from 8.9 to 4.3 (P levels in the epithelial cells of the patients, indicating PPAR...

  14. A NuSTAR Observation of the Gamma-Ray Emitting Millisecond Pulsar PSR J1723–2837

    Energy Technology Data Exchange (ETDEWEB)

    Kong, A. K. H. [Institute of Astronomy and Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Hui, C. Y. [Department of Astronomy and Space Science, Chungnam National University, Daejeon (Korea, Republic of); Takata, J. [Institute of Particle Physics and Astronomy, Huazhong University of Science and Technology (China); Li, K. L. [Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Tam, P. H. T., E-mail: akong@phys.nthu.edu.tw, E-mail: cyhui@cnu.ac.kr [School of Physics and Astronomy, Sun Yat-sen University, Zhuhai 519082 (China)

    2017-04-20

    We report on the first NuSTAR observation of the gamma-ray emitting millisecond pulsar binary PSR J1723–2837. X-ray radiation up to 79 keV is clearly detected, and the simultaneous NuSTAR and Swift spectrum is well described by an absorbed power law with a photon index of ∼1.3. We also find X-ray modulations in the 3–10, 10–20, 20–79, and 3–79 keV bands at the 14.8 hr binary orbital period. All of these are entirely consistent with previous X-ray observations below 10 keV. This new hard X-ray observation of PSR J1723–2837 provides strong evidence that the X-rays are from the intrabinary shock via an interaction between the pulsar wind and the outflow from the companion star. We discuss how the NuSTAR observation constrains the physical parameters of the intrabinary shock model.

  15. Application of gamma-spectrometry to post irradiation examination

    International Nuclear Information System (INIS)

    Kim, S.K.; Huh, Y.H.; Park, K.J.

    1982-01-01

    A areat variety of nuclear gamma rays emitted from fission and activation products of spent nuclear fuel contains much information that can be elicited without affecting the integrity of the fuel elements. In the present work, a versatile code CAERI was developed which locates peaks and calculates their areas for X-rays as well as gamma rays using elegant features of some widely used programs for gamma ray peak fitting. CAERI coded in FORTRAN used infinite series approximation more accurate than other workers' various, simple, piecewise series approximations for evaluation of the Voigt function which represents the X-ray peak with nonneglible natural line width. CAERI can handle even a complex multiplet consisting of peaks from X-rays and rays in arbitrary mixture, which one often encounters in the isotopic analysis of heavy elements such as U and Pu. (Author)

  16. IDENTIFICATION OF NEW GAMMA-RAY BLAZAR CANDIDATES WITH MULTIFREQUENCY ARCHIVAL OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Cowperthwaite, Philip S. [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Massaro, F. [SLAC National Laboratory and Kavli Institute for Particle Astrophysics and Cosmology, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); D' Abrusco, R.; Paggi, A.; Smith, Howard A. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Tosti, G., E-mail: pcowpert@umd.edu [Dipartimento di Fisica, Università Degli Studi di Perugia, I-06123 Perugia (Italy)

    2013-11-01

    Blazars are a highly variable, radio-loud subclass of active galactic nuclei. In order to better understand such objects we must be able to easily identify candidate blazars from the growing population of unidentified sources. Working toward this goal, we attempt to identify new gamma-ray blazar candidates from a sample of 102 previously unidentified sources. These sources are selected from The Astronomer's Telegram and the literature on the basis of non-periodic variability and multi-wavelength behavior. We then attempt to associate these objects to an IR counterpart in the Wide-field Infrared Survey Explorer all-sky survey. We are able to identify 16 candidate sources whose IR colors are consistent with those of the blazar population. Of those, 13 sources have IR colors indicative of being gamma-ray emitting blazar candidates. These sources all possess archival multi-wavelength observations that support their blazar-like nature.

  17. Gamma-spectrometric measurement of radioactivity in agricultural soils of the Lombardia region, northern Italy.

    Science.gov (United States)

    Guidotti, Laura; Carini, Franca; Rossi, Riccardo; Gatti, Marina; Cenci, Roberto M; Beone, Gian Maria

    2015-04-01

    This work is part of a wider monitoring project of the agricultural soils in Lombardia, which aims to build a database of topsoil properties and the potentially toxic elements, organic pollutants and gamma emitting radionuclides that the topsoils contain. A total of 156 agricultural soils were sampled according to the LUCAS (Land Use/Cover Area frame statistical Survey) standard procedure. The aim was to provide a baseline to document the conditions present at the time of sampling. The results of the project concerning soil radioactivity are presented here. The aim was to assess the content of (238)U, (232)Th, (137)Cs and (40)K by measuring soil samples by gamma spectrometry. (238)U, (232)Th and (40)K activities range 24-231, 20-70, and 242-1434 Bq kg(-1) respectively. The geographic distribution of (238)U reflects the geophysical framework of the Lombardia region: the soils with high content of uranium are distributed for the most part in the South Alpine belt, where the presence of magmatic rocks is widespread. These soils show an higher activity of (238)U than of (232)Th. The (238)U activities become lower than (232)Th when soils are located in the plain, originating from basic sedimentary rocks. (137)Cs activity ranges 0.4-86.8 kBq m(-2). The lowest activity of (137)Cs is in the plain, whereas the highest is in the North on soils kept as lawn or pasture. The (137)Cs activity of some samples suggests the presence of accumulation processes that lead to (137)Cs enriched soils. This is the first survey of gamma emitting radionuclides in Lombardia that is based on the LUCAS standard sampling. The results from this monitoring campaign are important for the human radiation exposure and provide the zero point, which will be useful for assessing future effects due to external factors such as human activities. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. High-Speed Semiconductor Vertical-Cavity Surface-Emitting Lasers for Optical Data-Transmission Systems (Review)

    Science.gov (United States)

    Blokhin, S. A.; Maleev, N. A.; Bobrov, M. A.; Kuzmenkov, A. G.; Sakharov, A. V.; Ustinov, V. M.

    2018-01-01

    The main problems of providing a high-speed operation semiconductor lasers with a vertical microcavity (so-called "vertical-cavity surface-emitting lasers") under amplitude modulation and ways to solve them have been considered. The influence of the internal properties of the radiating active region and the electrical parasitic elements of the equivalent circuit of lasers are discussed. An overview of approaches that lead to an increase of the cutoff parasitic frequency, an increase of the differential gain of the active region, the possibility of the management of mode emission composition and the lifetime of photons in the optical microcavities, and reduction of the influence of thermal effects have been presented. The achieved level of modulation bandwidth of ˜30 GHz is close to the maximum achievable for the classical scheme of the direct-current modulation, which makes it necessary to use a multilevel modulation format to further increase the information capacity of optical channels constructed on the basis of vertical-cavity surface-emitting lasers.

  19. Topical Rosiglitazone Treatment Improves Ulcerative Colitis by Restoring Peroxisome Proliferator-Activated Receptor-gamma Activity

    DEFF Research Database (Denmark)

    Pedersen, G.; Brynskov, Jørn

    2010-01-01

    OBJECTIVES: Impaired epithelial expression of peroxisome proliferator-activated receptor-gamma (PPAR gamma) has been described in animal colitis models and briefly in patients with ulcerative colitis, but the functional significance in humans is not well defined. We examined PPAR gamma expression...

  20. High Affinity IgE-Fc Receptor alpha and gamma Subunit Interactions

    International Nuclear Information System (INIS)

    Rashid, A.; Housden, J. E. M.; Sabban, S.; Helm, B.

    2014-01-01

    Objective: To explore the relationships between the subunits (alpha, beta and gamma) of the high affinity IgE receptor (Fc and RI) and its ability to mediate transmembrane signaling. Study Design: Experimental study. Place and Duration of Study: Department of Molecular Biology and Biotechnology, University of Sheffield, UK, from 2008 to 2009. Methodology: The approach employed was to create a chimera (human alpha-gamma-gamma) using the extracellular (EC) domain of the human high affinity IgE receptor. The alpha subunit (huFc and RIalpha) of IgE receptor was spliced onto the rodent gamma TM and cytoplasmic domain (CD). This was transfected into the Rat Basophilic Leukemia cell line in order to assess the possibility of selectively activating cells transfected with this single pass construct for antigen induced mediator release. Results: The RBLs cell lines transfected with the huFc and RIalpha/gamma/gamma cDNA constructs were assessed for the cell surface expression of the huFc and RIalpha subunit and the response to the antigenic stimulus by looking for degranulation and intracellular Ca2+ mobilisation. The results obtained showed the absence of huFc and RIalpha subunit expression on the surface of transfected cells as seen by flowcytometric studies, beta-hexosaminidase assays and intracellular calcium mobilisation studies. Conclusion: In the present study the grounds for non-expression of huFc and RIalpha/gamma/gamma cDNA remains elusive but may be due to the fact that the human-rodent chimeric receptors are assembled differently than the endogenous rodent receptors as seen in study in which COS 7 cells were transfected with human/rat chimeric complexes. (author)

  1. Seasonal distribution and uptake of gamma emitting radionuclides at the test reactor area leaching ponds

    International Nuclear Information System (INIS)

    Millard, J.B.

    1986-01-01

    Radioactive leaching ponds adjacent to the Test Reactor Area (TRA) located on the Idaho National Engineering Laboratory (INEL) site were investigated to determine the seasonal distribution and ecological behavior of gamma emitting radionuclides in various pond compartments. The physical, chemical and biological properties of the TRA ponds were documented including basic morphometry, water chemistry and species identification. Penetrating radiation exposure rates at the ponds ranged from 35 to 65 mR/d at the water surface and up to 3400 mR/d one meter above bottom sediments. Seasonal concentrations and concentration ratios were determined for 16 principle radionuclides in filtered water, sediment, seston, zooplankton, net plankton, nannoplankton, periphyton, macrophytes, thistle, speedwell and willow. Seston and nannoplankton had the highest concentration ratios with substantial decreases observed for higher trophic level compartments. Significant (P < 0.01 to P < 0.001) seasonal effects wee found for concentration ratios. Radionuclides without nutrient analogs had the highest ratios in spring for periphyton, macrophytes and littoral plants. Concentration ratios were highest in summer, fall or winter for radionuclides with nutrient analogs

  2. Very high energy gamma ray astrophysics

    International Nuclear Information System (INIS)

    Lamb, R.C.; Lewis, D.A.

    1991-01-01

    The Whipple Observatory High Resolution Camera will be used in a vigorous program of observations to search for new sources of very-high-energy gamma rays. In addition, a search for antimatter using the moon-earth system as an ion spectrometer will be begun. The first phase of GRANITE, the new 37-element 11-m camera, will be concluded with first light scheduled for September, 1991. The two cameras will operate in support of the Gamma Ray Observatory mission in the winter of 1991/2

  3. Nondestructive and quantitative characterization of TRU and LLW mixed-waste using active and passive gamma-ray spectrometry and computed tomography

    International Nuclear Information System (INIS)

    Camp, D.C.; Martz, H.E.

    1991-01-01

    The technology being proposed by LLNL is an Active and Passive Computed Tomography (A ampersand P CT) Drum Scanner for contact-handled (CH) wastes. It combines the advantages offered by two well-developed nondestructive assay technologies: gamma-ray spectrometry and computed tomography (CT). Coupled together, these two technologies offer to nondestructively and quantitatively characterize mixed- wastes forms. Gamma-ray spectroscopy uses one or more external radiation detectors to passively and nondestructively measure the energy spectrum emitted from a closed container. From the resulting spectrum one can identify most radioactivities detected, be they transuranic isotopes, mixed-fission products, activation products or environmental radioactivities. Spectral libraries exist at LLNL for all four. Active (A) or transmission CT is a well-developed, nondestructive medical and industrial technique that uses an external-radiation beam to map regions of varying attenuation within a container. Passive (P) or emission CT is a technique mainly developed for medical application, e.g., single-photon emission CT. Nondestructive industrial uses of PCT are under development and just coming into use. This report discuses work on the A ampersand P CT Drum Scanner at LLNL

  4. Gamma-activation analyses of 187 Os in molybdenite

    International Nuclear Information System (INIS)

    Dikij, N.P.; Dovbnya, A.N.; Borovlev, V.I.; Lyashko, Yu.V.; Medvedeva, E.P.; Uvarov, V.L.; Val'ter, A.A.; Storizhko, V.E.

    1999-01-01

    197 Os and 187 Re are used in cosmological studies. Common registration of gamma and X-ray irradiation in compositions containing these radioisotopes permits to increase the accuracy in determination of their content. The results of 187 Os gamma-activation analysis in molybdenite are presented

  5. High Intensity Organic Light-emitting Diodes

    Science.gov (United States)

    Qi, Xiangfei

    This thesis is dedicated to the fabrication, modeling, and characterization to achieve high efficiency organic light-emitting diodes (OLEDs) for illumination applications. Compared to conventional lighting sources, OLEDs enabled the direct conversion of electrical energy into light emission and have intrigued the world's lighting designers with the long-lasting, highly efficient illumination. We begin with a brief overview of organic technology, from basic organic semiconductor physics, to its application in optoelectronics, i.e. light-emitting diodes, photovoltaics, photodetectors and thin-film transistors. Due to the importance of phosphorescent materials, we will focus on the photophysics of metal complexes that is central to high efficiency OLED technology, followed by a transient study to examine the radiative decay dynamics in a series of phosphorescent platinum binuclear complexes. The major theme of this thesis is the design and optimization of a novel architecture where individual red, green and blue phosphorescent OLEDs are vertically stacked and electrically interconnected by the compound charge generation layers. We modeled carrier generation from the metal-oxide/doped organic interface based on a thermally assisted tunneling mechanism. The model provides insights to the optimization of a stacked OLED from both electrical and optical point of view. To realize the high intensity white lighting source, the efficient removal of heat is of a particular concern, especially in large-area devices. A fundamental transfer matrix analysis is introduced to predict the thermal properties in the devices. The analysis employs Laplace transforms to determine the response of the system to the combined effects of conduction, convection, and radiation. This perspective of constructing transmission matrices greatly facilitates the calculation of transient coupled heat transfer in a general multi-layer composite. It converts differential equations to algebraic forms, and

  6. Gamma-neutron activation experiments using laser wakefield accelerators

    International Nuclear Information System (INIS)

    Leemans, W.P.; Rodgers, D.; Catravas, P.E.; Geddes, C.G.R.; Fubiani, G.; Esarey, E.; Shadwick, B.A.; Donahue, R.; Smith, A.

    2001-01-01

    Gamma-neutron activation experiments have been performed with relativistic electron beams produced by a laser wakefield accelerator. The electron beams were produced by tightly focusing (spot diameter ≅6 μm) a high power (up to 10 TW), ultra-short (≥50 fs) laser beam from a high repetition rate (10 Hz) Ti:sapphire (0.8 μm) laser system, onto a high density (>10 19 cm -3 ) pulsed gasjet of length ≅1.5 mm. Nuclear activation measurements in lead and copper targets indicate the production of electrons with energy in excess of 25 MeV. This result was confirmed by electron distribution measurements using a bending magnet spectrometer. Measured γ-ray and neutron yields are also found to be in reasonable agreement with simulations using a Monte Carlo transport code

  7. Application of intrinsic germanium spectral gamma-ray logging for characterization of high-level nuclear waste tank leaks

    International Nuclear Information System (INIS)

    Brodeur, J.R.; Kiesler, J.P.; Kos, S.E.; Koizumi, C.J.; Nicaise, W.F.; Price, R.K.

    1993-11-01

    Spectral gamma-ray logging with a high-resolution, intrinsic germanium logging system was completed in boreholes surrounding two high-level nuclear waste tanks at the US Department of Energy's Hanford Site. The purpose was to characterize the concentrations of man-made radionuclides in the unsaturated zone sediments and identify any new leaks from the tanks. An intrinsic germanium detection system was used for this work because it was important to positively identify the specific radionuclides and to precisely assay those radionuclides. The spectral gamma log data were processed and displayed as log plots for each individual borehole and as three-dimensional plots of 137 Cs radionuclide concentrations. These data were reviewed to identify the sources of the contamination. The investigation did not uncover a new or active leak from either of the tanks. Most of the contamination found could be related to known pipeline leaks, to surface contamination from aboveground liquid spills, or to leaks from other tanks. The current spectral gamma ray data now provide a new baseline from which to compare future log data and identify any changes in the radioelement concentration

  8. High-power light-emitting diode based facility for plant cultivation

    Energy Technology Data Exchange (ETDEWEB)

    Tamulaitis, G [Institute of Materials Science and Applied Research, Vilnius University, Sauletekio al. 9-III, LT-10222 Vilnius (Lithuania); Duchovskis, P [Lithuanian Institute of Horticulture, Babtai, LT-54333 Kaunas District (Lithuania); Bliznikas, Z [Institute of Materials Science and Applied Research, Vilnius University, Sauletekio al. 9-III, LT-10222 Vilnius (Lithuania); Breive, K [Institute of Materials Science and Applied Research, Vilnius University, Sauletekio al. 9-III, LT-10222 Vilnius (Lithuania); Ulinskaite, R [Lithuanian Institute of Horticulture, Babtai, LT-54333 Kaunas District (Lithuania); Brazaityte, A [Lithuanian Institute of Horticulture, Babtai, LT-54333 Kaunas District (Lithuania); Novickovas, A [Institute of Materials Science and Applied Research, Vilnius University, Sauletekio al. 9-III, LT-10222 Vilnius (Lithuania); Zukauskas, A [Institute of Materials Science and Applied Research, Vilnius University, Sauletekio al. 9-III, LT-10222 Vilnius (Lithuania)

    2005-09-07

    Based on perspectives of the development of semiconductor materials systems for high-power light-emitting diodes (LEDs), an illumination facility for greenhouse plant cultivation was designed with the dominating 640 nm photosynthetically active component delivered by AlGaInP LEDs and supplementary components from AlGaN (photothropic action, 455 nm) and AlGaAs (photosynthetic 660 nm and photomorphogenetic 735 nm) LEDs. Photosynthesis intensity, photosynthetic productivity and growth morphology as well as chlorophyll and phytohormone concentrations were investigated in radish and lettuce grown in phytotron chambers under the LED-based illuminators and under high-pressure sodium (HPS) lamps with an equivalent photon flux density. Advantages of the high-power LED-based illuminators over conventional HPS lamps, applicability of AlGaInP LEDs for photosynthesis and control of plant growth by circadian manipulation of a relatively weak far-red component were demonstrated.

  9. High-power light-emitting diode based facility for plant cultivation

    International Nuclear Information System (INIS)

    Tamulaitis, G; Duchovskis, P; Bliznikas, Z; Breive, K; Ulinskaite, R; Brazaityte, A; Novickovas, A; Zukauskas, A

    2005-01-01

    Based on perspectives of the development of semiconductor materials systems for high-power light-emitting diodes (LEDs), an illumination facility for greenhouse plant cultivation was designed with the dominating 640 nm photosynthetically active component delivered by AlGaInP LEDs and supplementary components from AlGaN (photothropic action, 455 nm) and AlGaAs (photosynthetic 660 nm and photomorphogenetic 735 nm) LEDs. Photosynthesis intensity, photosynthetic productivity and growth morphology as well as chlorophyll and phytohormone concentrations were investigated in radish and lettuce grown in phytotron chambers under the LED-based illuminators and under high-pressure sodium (HPS) lamps with an equivalent photon flux density. Advantages of the high-power LED-based illuminators over conventional HPS lamps, applicability of AlGaInP LEDs for photosynthesis and control of plant growth by circadian manipulation of a relatively weak far-red component were demonstrated

  10. Report on the IAEA-CU-2006-03 world-wide open proficiency test on the determination of gamma emitting radionuclides

    International Nuclear Information System (INIS)

    Shakhashiro, A.; Sansone, U.; Trinkl, A.; Makarewicz, M.; Yonezawa, C.; Kim, C.K.; Kis-Benedek, G.; Benesch, T.; Schorn, R.

    2007-05-01

    The results of analytical measurements play a vital role in our daily lives. Analytical data may be the basis upon which economic, legal or environmental management decisions are made, and they are essential in international trade, environmental protection, safe transportation, law enforcement, consumer safety and the preservation of human health. As an incorrect decision can be extremely costly and detrimental, it is essential that such measurements are accurate, reliable, cost effective and defensible. In addition, measurements performed by laboratories located worldwide should yield traceable and comparable results. Proficiency testing is a method for regularly assessing the accuracy of the analytical data produced by the laboratories of particular measurements. The IAEA-CU-2006-03 world-wide proficiency test (PT) on the determination of gamma emitting radionuclides in water grass and soil is conducted by the Chemistry Unit of the IAEA's Laboratories located in Seibersdorf (Austria), which is actively involved in the production and characterization of matrix reference materials of terrestrial origin, widely used for method validation and organization of proficiency tests and intercomparison studies. The Chemistry Unit is a part of the Physics, Chemistry and Instrumentation Laboratory. This report describes the sample preparation methodology, data evaluation approach, summary evaluation of each nuclide and individual evaluation report for each laboratory

  11. Detection of 16 Gamma-Ray Pulsars Through Blind Frequency Searches Using the Fermi LAT

    International Nuclear Information System (INIS)

    Anderson, B.; Atwood, W.B.; Dormody, M.; Johnson, R.P.; Porter, T.A.; Primack, J.R.; Sadrozinski, H.F.W.; Parkinson, P.M.S.; Ziegler, M.; Abdo, A.A.; Dermer, C.D.; Grove, J.E.; Gwon, C.; Johnson, W.N.; Lovellette, M.N.; Makeev, A.; Ray, P.S.; Strickman, M.S.; Wolff, M.T.; Wood, K.S.; Ackermann, M.; Ajello, M.; Bechtol, K.; Berenji, B.; Blandford, R.D.; Borgland, A.W.; Cameron, R.A.; Chiang, J.; Claus, R.; Digel, S.W.; Silva, E.D.E.; Drell, P.S.; Dubois, R.; Funk, S.; Glanzman, T.; Godfrey, G.; Hayashida, M.; Johannesson, G.; Kamae, T.; Kocian, M.L.; Lande, J.; Madejski, G.M.; Michelson, P.F.; Mitthumsiri, W.; Monzani, M.E.; Moskalenko, I.V.; Murgia, S.; Nolan, P.L.; Paneque, D.; Reimer, A.; Reimer, O.; Rochester, L.S.; Romani, R.W.; Tajima, H.; Tanaka, T.; Thayer, J.G.; Tramacere, A.; Uchiyama, Y.; Usher, T.L.; Van Etten, A.; Waite, A.P.; Wang, P.; Watters, K.; Ackermann, M.; Ajello, M.; Bechtol, K.; Berenji, B.; Bloom, E.D.; Borgland, A.W.; Cameron, R.A.; Chiang, J.; Claus, R.; Digel, S.W.; Silva, E.D.E.; Drell, P.S.; Dubois, R.; Glanzman, T.; Godfrey, G.; Hayashida, M.; Johannesson, G.; Kamae, T.; Kocian, M.L.; Lande, J.; Madejski, G.M.; Michelson, P.F.; Mitthumsiri, W.; Monzani, M.E.; Moskalenko, I.V.; Murgia, S.; Nolan, P.L.; Paneque, D.; Reimer, A.; Reimer, O.; Rochester, L.S.; Romani, R.W.; Tajima, H.; Tanaka, T.; Thayer, J.G.; Tramacere, A.; Uchiyama, Y.; Usher, T.L.; Van Etten, A.; Waite, A.P.; Wang, P.; Watters, K.; Axelsson, M.; Conrad, J.; Meurer, C.; Ryde, F.; Ylinen, T.; Axelsson, M.; Baldini, L.; Bellazzini, R.; Bregeon, J.; Brez, A.; Kuss, M.; Latronico, L.; Omodei, N.; Pesce-Rollins, M.; Razzano, M.; Sgro, C.; Spandre, G.; Ballet, J.; Casandjian, J.M.; Grenier, I.A.; Pierbattista, M.; Starck, J.L.

    2009-01-01

    Pulsars are rapidly rotating, highly magnetized neutron stars emitting radiation across the electromagnetic spectrum. Although there are more than 1800 known radio pulsars, until recently only seven were observed to pulse in gamma rays, and these were all discovered at other wavelengths. The Fermi Large Area Telescope (LAT) makes it possible to pinpoint neutron stars through their gamma-ray pulsations. We report the detection of 16 gamma-ray pulsars in blind frequency searches using the LAT. Most of these pulsars are coincident with previously unidentified gamma-ray sources, and many are associated with supernova remnants. Direct detection of gamma-ray pulsars enables studies of emission mechanisms, population statistics, and the energetics of pulsar wind nebulae and supernova remnants. (authors)

  12. Highly accurate determination of relative gamma-ray detection efficiency for Ge detector and its application

    International Nuclear Information System (INIS)

    Miyahara, H.; Mori, C.; Fleming, R.F.; Dewaraja, Y.K.

    1997-01-01

    When quantitative measurements of γ-rays using High-Purity Ge (HPGe) detectors are made for a variety of applications, accurate knowledge of oy-ray detection efficiency is required. The emission rates of γ-rays from sources can be determined quickly in the case that the absolute peak efficiency is calibrated. On the other hand, the relative peak efficiencies can be used for determination of intensity ratios for plural samples and for comparison to the standard source. Thus, both absolute and relative detection efficiencies are important in use of γ-ray detector. The objective of this work is to determine the relative gamma-ray peak detection efficiency for an HPGe detector with the uncertainty approaching 0.1% . We used some nuclides which emit at least two gamma-rays with energies from 700 to 2400 keV for which the relative emission probabilities are known with uncertainties much smaller than 0.1%. The relative peak detection efficiencies were calculated from the measurements of the nuclides, 46 Sc, 48 Sc, 60 Co and 94 Nb, emitting two γ- rays with the emission probabilities of almost unity. It is important that various corrections for the emission probabilities, the cascade summing effect, and the self-absorption are small. A third order polynomial function on both logarithmic scales of energy and efficiency was fitted to the data, and the peak efficiency predicted at certain energy from covariance matrix showed the uncertainty less than 0.5% except for near 700 keV. As an application, the emission probabilities of the 1037.5 and 1212.9 keV γ-rays for 48 Sc were determined using the function of the highly precise relative peak efficiency. Those were 0.9777+0,.00079 and 0.02345+0.00017 for the 1037.5 and 1212.9 keV γ-rays, respectively. The sum of these probabilities is close to unity within the uncertainty which means that the certainties of the results are high and the accuracy has been improved considerably

  13. High-resolution gamma ray attenuation density measurements on mining exploration drill cores, including cut cores

    Science.gov (United States)

    Ross, P.-S.; Bourke, A.

    2017-01-01

    Physical property measurements are increasingly important in mining exploration. For density determinations on rocks, one method applicable on exploration drill cores relies on gamma ray attenuation. This non-destructive method is ideal because each measurement takes only 10 s, making it suitable for high-resolution logging. However calibration has been problematic. In this paper we present new empirical, site-specific correction equations for whole NQ and BQ cores. The corrections force back the gamma densities to the "true" values established by the immersion method. For the NQ core caliber, the density range extends to high values (massive pyrite, 5 g/cm3) and the correction is thought to be very robust. We also present additional empirical correction factors for cut cores which take into account the missing material. These "cut core correction factors", which are not site-specific, were established by making gamma density measurements on truncated aluminum cylinders of various residual thicknesses. Finally we show two examples of application for the Abitibi Greenstone Belt in Canada. The gamma ray attenuation measurement system is part of a multi-sensor core logger which also determines magnetic susceptibility, geochemistry and mineralogy on rock cores, and performs line-scan imaging.

  14. Found: A Galaxy's Missing Gamma Rays

    Science.gov (United States)

    Kohler, Susanna

    2016-04-01

    Recent reanalysis of data from the Fermi Gamma-ray Space Telescope has resulted in the first detection of high-energy gamma rays emitted from a nearby galaxy. This discovery reveals more about how supernovae interact with their environments.Colliding Supernova RemnantAfter a stellar explosion, the supernovas ejecta expand, eventually encountering the ambient interstellar medium. According to models, this generates a strong shock, and a fraction of the kinetic energy of the ejecta is transferred into cosmic rays high-energy radiation composed primarily of protons and atomic nuclei. Much is still unknown about this process, however. One open question is: what fraction of the supernovas explosion power goes into accelerating these cosmic rays?In theory, one way to answer this is by looking for gamma rays. In a starburst galaxy, the collision of the supernova-accelerated cosmic rays with the dense interstellar medium is predicted to produce high-energy gamma rays. That radiation should then escape the galaxy and be visible to us.Pass 8 to the RescueObservational tests of this model, however, have beenstumped by Arp 220. This nearby ultraluminous infrared galaxy is the product of a galaxy merger ~700 million years ago that fueled a frenzy of starbirth. Due to its dusty interior and extreme levels of star formation, Arp 220 has long been predicted to emit the gamma rays produced by supernova-accelerated cosmic rays. But though weve looked, gamma-ray emission has never been detected from this galaxy until now.In a recent study, a team of scientists led by Fang-Kun Peng (Nanjing University) reprocessed 7.5 years of Fermi observations using the new Pass 8 analysis software. The resulting increase in resolution revealed the first detection of GeV emission from Arp 220!Acceleration EfficiencyGamma-ray luminosity vs. total infrared luminosity for LAT-detected star-forming galaxies and Seyferts. Arp 220s luminosities are consistent with the scaling relation. [Peng et al. 2016

  15. Breast-specific gamma-imaging: molecular imaging of the breast using 99mTc-sestamibi and a small-field-of-view gamma-camera.

    Science.gov (United States)

    Jones, Elizabeth A; Phan, Trinh D; Blanchard, Deborah A; Miley, Abbe

    2009-12-01

    Breast-specific gamma-imaging (BSGI), also known as molecular breast imaging, is breast scintigraphy using a small-field-of-view gamma-camera and (99m)Tc-sestamibi. There are many different types of breast cancer, and many have characteristics making them challenging to detect by mammography and ultrasound. BSGI is a cost-effective, highly sensitive and specific technique that complements other imaging modalities currently being used to identify malignant lesions in the breast. Using the current Society of Nuclear Medicine guidelines for breast scintigraphy, Legacy Good Samaritan Hospital began conducting BSGI, breast scintigraphy with a breast-optimized gamma-camera. In our experience, optimal imaging has been conducted in the Breast Center by a nuclear medicine technologist. In addition, the breast radiologists read the BSGI images in correlation with the mammograms, ultrasounds, and other imaging studies performed. By modifying the current Society of Nuclear Medicine protocol to adapt it to the practice of breast scintigraphy with these new systems and by providing image interpretation in conjunction with the other breast imaging studies, our center has found BSGI to be a valuable adjunctive procedure in the diagnosis of breast cancer. The development of a small-field-of-view gamma-camera, designed to optimize breast imaging, has resulted in improved detection capabilities, particularly for lesions less than 1 cm. Our experience with this procedure has proven to aid in the clinical work-up of many of our breast patients. After reading this article, the reader should understand the history of breast scintigraphy, the pharmaceutical used, patient preparation and positioning, imaging protocol guidelines, clinical indications, and the role of breast scintigraphy in breast cancer diagnosis.

  16. A semianalytical method for calculating the parameters of the electromagnetic halos around extragalactic gamma-ray sources

    NARCIS (Netherlands)

    Kel'ner, [No Value; Khangulyan, DV; Aharonian, FA

    2004-01-01

    The ultrahigh-energy (>20 TeV) gamma rays emitted by active galactic nuclei can be absorbed in intergalactic space through the production of electron-positron pairs during their interaction with extragalactic background photon fields. The electrons and positrons produced by this interaction form an

  17. Observation of solar gamma-ray by Hinotori

    International Nuclear Information System (INIS)

    Yoshimori, Masato; Okudaira, Kiyoaki; Hirashima, Yo; Kondo, Ichiro.

    1982-01-01

    The solar gamma-ray emitted by solar flare was observed. The gamma-ray is the electromagnetic radiation with the energy more than 300 keV. The line gamma-ray intensity and the time profile were observed. The gamma-ray detector CsI (Tl) was loaded on Hinotori, and the observed gamma-ray was analyzed by a multi-channel analyzer. The observed line gamma-ray was the radiation from Fe-56 and Ne-20. The line gamma-ray from C-12 and O-16 was also seen. These gamma-ray is the direct evidence of the nuclear reaction on the sun. The observed spectrum suggested the existence of the lines from Mg-24 and Si-28. The intensity of the 2.22 MeV gamma-line was small. This fact showed that the origin of this line was different from other nuclear gamma-ray. Two kinds of hard X-ray bursts were detected. The one was impulsive burst, and the other was gradual burst. There was no time difference between the hard X-ray and the gamma-ray of the impulsive burst. The impulsive burst may be explained by the beam model. The delay of time profile in the high energy gamma-ray of the gradual burst was observed. This means that the time when accelerated electrons cause bremsstrahlung depends on the electron energy. The long trapping of electrons at the top of magnetic loop is suggested. (Kato, T.)

  18. Use of prompt gamma emissions from polyethylene to estimate neutron ambient dose equivalent

    Energy Technology Data Exchange (ETDEWEB)

    Priyada, P.; Sarkar, P.K., E-mail: pradip.sarkar@manipal.edu

    2015-06-11

    The possibility of using measured prompt gamma emissions from polyethylene to estimate neutron ambient dose equivalent is explored theoretically. Monte Carlo simulations have been carried out using the FLUKA code to calculate the response of a high density polyethylene cylinder to emit prompt gammas from interaction of neutrons with the nuclei of hydrogen and carbon present in polyethylene. The neutron energy dependent responses of hydrogen and carbon nuclei are combined appropriately to match the energy dependent neutron fluence to ambient dose equivalent conversion coefficients. The proposed method is tested initially with simulated spectra and then validated using experimental measurements with an Am–Be neutron source. Experimental measurements and theoretical simulations have established the feasibility of estimating neutron ambient dose equivalent using measured neutron induced prompt gammas emitted from polyethylene with an overestimation of neutron dose at very low energies. - Highlights: • A new method for estimating H{sup ⁎}(10) using prompt gamma emissions from HDPE. • Linear combination of 2.2 MeV and 4.4 MeV gamma intensities approximates DCC (ICRP). • Feasibility of the method was established theoretically and experimentally. • The response of the present technique is very similar to that of the rem meters.

  19. Laboratory of High resolution gamma spectrometry; Laboratorio de espectrometria gamma de alta resolucion

    Energy Technology Data Exchange (ETDEWEB)

    Mendez G, A.; Giber F, J.; Rivas C, I.; Reyes A, B

    1992-01-15

    The Department of Nuclear Experimentation of the Nuclear Systems Management requests the collaboration of the Engineering unit for the supervision of the execution of the work of the High resolution Gamma spectrometry and low bottom laboratory, using the hut of the sub critic reactor of the Nuclear Center of Mexico. This laboratory has the purpose of determining the activity of special materials irradiated in nuclear power plants. In this report the architecture development, concepts, materials and diagrams for the realization of this type of work are presented. (Author)

  20. Category-specific visual responses: an intracranial study comparing gamma, beta, alpha and ERP response selectivity

    Directory of Open Access Journals (Sweden)

    Juan R Vidal

    2010-11-01

    Full Text Available The specificity of neural responses to visual objects is a major topic in visual neuroscience. In humans, functional magnetic resonance imaging (fMRI studies have identified several regions of the occipital and temporal lobe that appear specific to faces, letter-strings, scenes, or tools. Direct electrophysiological recordings in the visual cortical areas of epileptic patients have largely confirmed this modular organization, using either single-neuron peri-stimulus time-histogram or intracerebral event-related potentials (iERP. In parallel, a new research stream has emerged using high-frequency gamma-band activity (50-150 Hz (GBR and low-frequency alpha/beta activity (8-24 Hz (ABR to map functional networks in humans. An obvious question is now whether the functional organization of the visual cortex revealed by fMRI, ERP, GBR, and ABR coincide. We used direct intracerebral recordings in 18 epileptic patients to directly compare GBR, ABR, and ERP elicited by the presentation of seven major visual object categories (faces, scenes, houses, consonants, pseudowords, tools, and animals, in relation to previous fMRI studies. Remarkably both GBR and iERP showed strong category-specificity that was in many cases sufficient to infer stimulus object category from the neural response at single-trial level. However, we also found a strong discrepancy between the selectivity of GBR, ABR, and ERP with less than 10% of spatial overlap between sites eliciting the same category-specificity. Overall, we found that selective neural responses to visual objects were broadly distributed in the brain with a prominent spatial cluster located in the posterior temporal cortex. Moreover, the different neural markers (GBR, ABR, and iERP that elicit selectivity towards specific visual object categories present little spatial overlap suggesting that the information content of each marker can uniquely characterize high-level visual information in the brain.

  1. Measurement of characteristic prompt gamma rays emitted from oxygen and carbon in tissue-equivalent samples during proton beam irradiation.

    Science.gov (United States)

    Polf, Jerimy C; Panthi, Rajesh; Mackin, Dennis S; McCleskey, Matt; Saastamoinen, Antti; Roeder, Brian T; Beddar, Sam

    2013-09-07

    The purpose of this work was to characterize how prompt gamma (PG) emission from tissue changes as a function of carbon and oxygen concentration, and to assess the feasibility of determining elemental concentration in tissues irradiated with proton beams. For this study, four tissue-equivalent water-sucrose samples with differing densities and concentrations of carbon, hydrogen, and oxygen were irradiated with a 48 MeV proton pencil beam. The PG spectrum emitted from each sample was measured using a high-purity germanium detector, and the absolute detection efficiency of the detector, average beam current, and delivered dose distribution were also measured. Changes to the total PG emission from (12)C (4.44 MeV) and (16)O (6.13 MeV) per incident proton and per Gray of absorbed dose were characterized as a function of carbon and oxygen concentration in the sample. The intensity of the 4.44 MeV PG emission per incident proton was found to be nearly constant for all samples regardless of their carbon concentration. However, we found that the 6.13 MeV PG emission increased linearly with the total amount (in grams) of oxygen irradiated in the sample. From the measured PG data, we determined that 1.64 × 10(7) oxygen PGs were emitted per gram of oxygen irradiated per Gray of absorbed dose delivered with a 48 MeV proton beam. These results indicate that the 6.13 MeV PG emission from (16)O is proportional to the concentration of oxygen in tissue irradiated with proton beams, showing that it is possible to determine the concentration of oxygen within tissues irradiated with proton beams by measuring (16)O PG emission.

  2. High and low energy gamma beam dump designs for the gamma beam delivery system at ELI-NP

    International Nuclear Information System (INIS)

    Yasin, Zafar; Matei, Catalin; Ur, Calin A.; Mitu, Iani-Octavian; Udup, Emil; Petcu, Cristian

    2016-01-01

    The Extreme Light Infrastructure - Nuclear Physics (ELI-NP) is under construction in Magurele, Bucharest, Romania. The facility will use two 10 PW lasers and a high intensity, narrow bandwidth gamma beam for stand-alone and combined laser-gamma experiments. The accurate estimation of particle doses and their restriction within the limits for both personel and general public is very important in the design phase of any nuclear facility. In the present work, Monte Carlo simulations are performed using FLUKA and MCNPX to design 19.4 and 4 MeV gamma beam dumps along with shielding of experimental areas. Dose rate contour plots from both FLUKA and MCNPX along with numerical values of doses in experimental area E8 of the facility are performed. The calculated doses are within the permissible limits. Furthermore, a reasonable agreement between both codes enhances our confidence in using one or both of them for future calculations in beam dump designs, radiation shielding, radioactive inventory, and other calculations releated to radiation protection. Residual dose rates and residual activity calculations are also performed for high-energy beam dump and their effect is negligible in comparison to contributions from prompt radiation.

  3. High and low energy gamma beam dump designs for the gamma beam delivery system at ELI-NP

    Energy Technology Data Exchange (ETDEWEB)

    Yasin, Zafar, E-mail: zafar.yasin@eli-np.ro; Matei, Catalin; Ur, Calin A.; Mitu, Iani-Octavian; Udup, Emil; Petcu, Cristian [Extreme Light Infrastructure - Nuclear Physics / Horia Hulubei National Institute for R& D in Physics and Nuclear Engineering, Bucharest-Magurele (Romania)

    2016-03-25

    The Extreme Light Infrastructure - Nuclear Physics (ELI-NP) is under construction in Magurele, Bucharest, Romania. The facility will use two 10 PW lasers and a high intensity, narrow bandwidth gamma beam for stand-alone and combined laser-gamma experiments. The accurate estimation of particle doses and their restriction within the limits for both personel and general public is very important in the design phase of any nuclear facility. In the present work, Monte Carlo simulations are performed using FLUKA and MCNPX to design 19.4 and 4 MeV gamma beam dumps along with shielding of experimental areas. Dose rate contour plots from both FLUKA and MCNPX along with numerical values of doses in experimental area E8 of the facility are performed. The calculated doses are within the permissible limits. Furthermore, a reasonable agreement between both codes enhances our confidence in using one or both of them for future calculations in beam dump designs, radiation shielding, radioactive inventory, and other calculations releated to radiation protection. Residual dose rates and residual activity calculations are also performed for high-energy beam dump and their effect is negligible in comparison to contributions from prompt radiation.

  4. Specific gamma-ray dose constants for nuclides important to dosimetry and radiological assessment

    International Nuclear Information System (INIS)

    Unger, L.M.; Trubey, D.K.

    1982-05-01

    Tables of specific gamma-ray dose constants (the unshielded gamma-ray dose equivalent rate at 1 m from a point source) have been computed for approximately 500 nuclides important to dosimetry and radiological assessment. The half life, the mean attenuation coefficient, and thickness for a lead shield providing 95% dose equivalent attenuation are also listed

  5. Production of interferon-gamma by in vivo tumor-sensitized T cells: Association with active antitumor immunity

    International Nuclear Information System (INIS)

    Bursuker, I.; Pearce, M.T.

    1990-01-01

    The state of active immunity to Meth A fibrosarcoma in mice immunized with an admixture of Meth A cells and Propionibacterium acnes is associated with possession by the host of spleen cells capable of producing interferon-gamma (IFN-gamma) upon in vitro restimulation with irradiated tumor cells. The ability of spleen cells from immunized mice to produce IFN-gamma in response to irradiated Meth A cells decays as active antitumor immunity is replaced by a state of immunological memory. The IFN-producing cells are L3T4+Ly2+, cyclophosphamide-sensitive and radiosensitive T cells, as determined by their sensitivity to corresponding monoclonal antibodies and complement. The induction of IFN-gamma production by in vivo tumor-sensitized T cells is tumor specific, in that spleen cells from mice immunized against Meth A fibrosarcoma can produce IFN in response to irradiated Meth A cells but not in response to another syngeneic tumor M109 lung carcinoma

  6. Extragalactic Gamma-Ray Astrophysics

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    During the last decades, various classes of radio-loud active galactic nuclei have been established as sources of high-energy radiation extending over a very broad range from soft gamma-rays (photon energies E~MeV) up to very-high-energy gamma-rays (E>100 GeV). These include blazars of different types, as well as young and evolved radio galaxies. The observed gamma-ray emission from such implies efficient particle acceleration processes taking place in highly magnetized and relativistic jets produced by supermassive black holes, processes that have yet to be identified and properly understood. In addition, nearby starforming and starburst galaxies, some of which host radio-quiet Seyfert-type nuclei, have been detected in the gamma-ray range as well. In their cases, the observed gamma-ray emission is due to non-thermal activity in the interstellar medium, possibly including also a contribution from accretion disks and nuclear outflows. Finally, the high-energy emission from clusters of galaxies remains elusive...

  7. Very high energy gamma-ray astronomy

    International Nuclear Information System (INIS)

    Weekes, T.C.

    1988-01-01

    Current interest in gamma-ray astronomy at energies above 100 GeV comes from the identification of Cygnus X-3 and other X-ray binaries as sources. In addition there are reports of emission from radio pulsars and a variety of other objects. The statistical significance of many of the observations is not high and many reported effects await confirmation, but there are a sufficient number of independent reports that very high energy gamma-ray astronomy must now be considered to have an observational basis. The observations are summarized with particular emphasis on those reported since 1980. The techniques used - the detection of small air showers using the secondary photons and particles at ground level - are unusual and are described. Future prospects for the field are discussed in relation to new ground-based experiments, satellite gamma-ray studies and proposed neutrino astronomy experiments. (orig.) With 296 refs

  8. Minimum Detectable Activity for Tomographic Gamma Scanning System

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Ram [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Smith, Susan [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Kirkpatrick, J. M. [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Croft, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographic Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each “view” is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities

  9. Gamma-ray angular distribution and correlation measurement. II

    International Nuclear Information System (INIS)

    Twin, P.J.

    1975-01-01

    Angular correlations of γ-rays following nuclear reactions depend, in general, on some alignment of the γ-emitting initial state. The methods of alignment are briefly discussed and then the techniques and experimental methods associated with direct angular distributions, particle-gamma correlations, gamma-gamma correlations and linear polarization correlations are dealt with. Finally the inherent ambiguities which arise when different spin and delta values give identical correlations are discussed for the simple direct and particle-gamma correlations together with the question whether the larger information content of gamma-gamma and linear polarization correlations can resolve these ambiguities. (Auth.)

  10. Dopamine D4 receptor activation increases hippocampal gamma oscillations by enhancing synchronization of fast-spiking interneurons.

    Directory of Open Access Journals (Sweden)

    Richard Andersson

    Full Text Available BACKGROUND: Gamma oscillations are electric activity patterns of the mammalian brain hypothesized to serve attention, sensory perception, working memory and memory encoding. They are disrupted or altered in schizophrenic patients with associated cognitive deficits, which persist in spite of treatment with antipsychotics. Because cognitive symptoms are a core feature of schizophrenia it is relevant to explore signaling pathways that potentially regulate gamma oscillations. Dopamine has been reported to decrease gamma oscillation power via D1-like receptors. Based on the expression pattern of D4 receptors (D4R in hippocampus, and pharmacological effects of D4R ligands in animals, we hypothesize that they are in a position to regulate gamma oscillations as well. METHODOLOGY/PRINCIPAL FINDINGS: To address this hypothesis we use rat hippocampal slices and kainate-induced gamma oscillations. Local field potential recordings as well as intracellular recordings of pyramidal cells, fast-spiking and non-fast-spiking interneurons were carried out. We show that D4R activation with the selective ligand PD168077 increases gamma oscillation power, which can be blocked by the D4R-specific antagonist L745,870 as well as by the antipsychotic drug Clozapine. Pyramidal cells did not exhibit changes in excitatory or inhibitory synaptic current amplitudes, but inhibitory currents became more coherent with the oscillations after application of PD168077. Fast-spiking, but not non-fast spiking, interneurons, increase their action potential phase-coupling and coherence with regard to ongoing gamma oscillations in response to D4R activation. Among several possible mechanisms we found that the NMDA receptor antagonist AP5 also blocks the D4R mediated increase in gamma oscillation power. CONCLUSIONS/SIGNIFICANCE: We conclude that D4R activation affects fast-spiking interneuron synchronization and thereby increases gamma power by an NMDA receptor-dependent mechanism. This

  11. Hard beta and gamma emissions of 124I. Impact on occupational dose in PET/CT.

    Science.gov (United States)

    Kemerink, G J; Franssen, R; Visser, M G W; Urbach, C J A; Halders, S G E A; Frantzen, M J; Brans, B; Teule, G J J; Mottaghy, F M

    2011-01-01

    The hard beta and gamma radiation of 124I can cause high doses to PET/CT workers. In this study we tried to quantify this occupational exposure and to optimize radioprotection. Thin MCP-Ns thermoluminescent dosimeters suitable for measuring beta and gamma radiation were used for extremity dosimetry, active personal dosimeters for whole-body dosimetry. Extremity doses were determined during dispensing of 124I and oral administration of the activity to the patient, the body dose during all phases of the PET/CT procedure. In addition, dose rates of vials and syringes as used in clinical practice were measured. The procedure for dispensing 124I was optimized using newly developed shielding. Skin dose rates up to 100 mSv/min were measured when in contact with the manufacturer's vial containing 370 MBq of 124I. For an unshielded 5 ml syringe the positron skin dose was about seven times the gamma dose. Before optimization of the preparation of 124I, using an already reasonably safe technique, the highest mean skin dose caused by handling 370 MBq was 1.9 mSv (max. 4.4 mSv). After optimization the skin dose was below 0.2 mSv. The highly energetic positrons emitted by 124I can cause high skin doses if radioprotection is poor. Under optimized conditions occupational doses are acceptable. Education of workers is of paramount importance.

  12. Conditioning the gamma spectrometer for activity measurement at very high background

    OpenAIRE

    Yan, Weihua; Zhang, Liguo; Zhang, Zhao; Xiao, Zhigang

    2013-01-01

    The application of a high purity germanium (HPGe) gamma spectrometer in determining the fuel element burnup in a future reactor is studied. The HPGe detector is exposed by a Co60 source with varying irradiation rate from 10 kcps to 150 kcps to simulate the input counting rate in real reactor environment. A Cs137 and a Eu152 source are positioned at given distances to generate certain event rate in the detector with the former being proposed as a labeling nuclide to measure the burnup of fuel ...

  13. The level of PPD-specific IFN-gamma-producing CD4+ T cells in the blood predicts the in vivo response to PPD.

    Science.gov (United States)

    Martins, Marcia Valéria B S; Lima, Mônica Cristina B S; Duppre, Nadia C; Matos, Haroldo J; Spencer, John S; Brennan, Patrick J; Sarno, Euzenir N; Fonseca, Leila; Pereira, Geraldo M B; Pessolani, Maria Cristina V

    2007-05-01

    There are no reliable means for detecting subclinical mycobacterial infections. The recent sequencing of several mycobacterial genomes has now afforded new opportunities for the development of pathogen-specific diagnostic tests, critical in the context of leprosy and tuberculosis control. In the present study, we applied a multi-parametric flow cytometric analysis that allowed the investigation of T-cell functions in order to define immunological markers that measure previous exposure to mycobacteria. We compared the in vivo response to PPD, the gold standard skin test reagent for measuring previous exposure to Mycobacterium tuberculosis, with in vitro parameters of leukocyte activation in five PPD positive and five PPD negative healthy volunteers. PPD-stimulated peripheral leukocytes expressing CD4, CD69, cutaneous lymphocyte-associated antigen (CLA) and intracellular IFN-gamma were enumerated in whole blood and compared with the size of in vivo PPD-induced induration and IFN-gamma production levels as measured by ELISA in supernatants of PPD-stimulated peripheral blood mononuclear cells. The reactivity to the tuberculin skin test (TST) was associated with markedly increased frequencies of PPD-responsive activated (CD69+) and IFN-gamma-producing CD4+T cells. Detection of PPD-specific IFN-gamma producing leukocytes was restricted to CD4+T cells and a subset of these cells was shown to express the skin homing molecule CLA. Multiple linear regression modeling of responses to PPD showed the highest association between skin test indurations and frequencies of PPD-responsive IFN-gamma-producing CD4+CD69+ T cells. Our data show that the in vitro enumeration of antigen-specific IFN-gamma-producing CD4+ T cells can provide an alternative to the in vivo tuberculin test for the detection of latent Mycobacterium tuberculosis infection. Moreover, the measurement of these immunological parameters can be useful for the screening of new specific antigens defined by the genome

  14. Multi-parameter study of gammas capture

    International Nuclear Information System (INIS)

    Samama, R.; Nifenecker, H.; Carlos, P.; Delaitre, B.

    1966-06-01

    This equipment is intended for analyzing, recording, and reading simultaneous information from several 'gamma' detectors. It allows multiparameter study of γ-γ cascades emitted after thermal neutrons capture. (authors) [fr

  15. National Uranium Resource Evaluation. General procedure for calibration and reduction of aerial gamma-ray measurements: specification BFEC 1250-B

    International Nuclear Information System (INIS)

    Purvance, D.; Novak, E.

    1983-12-01

    The information contained in this specification was acquired over the course of the US Department of Energy (DOE) National Uranium Resource Evaluation (NURE) program during the period 1974 through 1982. NURE was a program of the DOE Grand Junction Area Office to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States. Bendix Field Engineering Corporation (BFEC) has been the operating contractor for the DOE Grand Junction facility. The requirements stipulated herein had been incorporated as contractual specifications for the various subcontractors engaged in the aerial gamma-ray surveys, which were a major aspect of the NURE program. Although this phase of NURE activities has been completed, there exists valuable knowledge gained from these years of experience in the calibration of gamma-ray spectrometer systems and in the reduction of calibration data. Specification BFEC 1250-B is being open-filed by the US Department of Energy at this time to make this knowledge available to those desiring to apply gamma-ray spectrometry to other geophysical problems

  16. Precision Gamma-Ray Branching Ratios for Long-Lived Radioactive Nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Tonchev, Anton [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-10-19

    Many properties of the high-energy-density environments in nuclear weapons tests, advanced laser-fusion experiments, the interior of stars, and other astrophysical bodies must be inferred from the resulting long-lived radioactive nuclei that are produced. These radioactive nuclei are most easily and sensitively identified by studying the characteristic gamma rays emitted during decay. Measuring a number of decays via detection of the characteristic gamma-rays emitted during the gamma-decay (the gamma-ray branching ratio) of the long-lived fission products is one of the most straightforward and reliable ways to determine the number of fissions that occurred in a nuclear weapon test. The fission products 147Nd, 144Ce, 156Eu, and certain other long-lived isotopes play a crucial role in science-based stockpile stewardship, however, the large uncertainties (about 8%) on the branching ratios measured for these isotopes are currently limiting the usefulness of the existing data [1,2]. We performed highly accurate gamma-ray branching-ratio measurements for a group of high-atomic-number rare earth isotopes to greatly improve the precision and reliability with which the fission yield and reaction products in high-energy-density environments can be determined. We have developed techniques that take advantage of new radioactive-beam facilities, such as DOE's CARIBU located at Argonne National Laboratory, to produce radioactive samples and perform decay spectroscopy measurements. The absolute gamma-ray branching ratios for 147Nd and 144Ce are reduced <2% precision. In addition, high-energy monoenergetic neutron beams from the FN Tandem accelerator in TUNL at Duke University was used to produce 167Tm using the 169Tm(n,3n) reaction. Fourtime improved branching ratio of 167Tm is used now to measure reaction-in-flight (RIF) neutrons from a burning DT capsule at NIF [10]. This represents the

  17. Several experimental applications of gamma ray spectrometry on the analysis of uranium compounds

    International Nuclear Information System (INIS)

    Korob, Ricardo O.; Blasiyh Nuno, Guillermo A.

    2002-01-01

    Several experimental applications of gamma ray spectrometry on the analysis of uranium compounds and materials containing it are studied. Special attention is devoted to the correlation between experimental spectra and the decay chains of 235 U and 238 U contained in the analyzed samples. The following applications are discussed: enrichment determination without using calibration standards, determination of uranium concentration, intensities of the gamma rays emitted by the nuclides present in the decay chains of study and the activity of such nuclides. Because of its importance, detailed discussion about the former one is shown. In addition, preliminary results regarding the emission probabilities of the most important gamma rays of 234m Pa are also informed. (author)

  18. Liver-Specific Activation of AMPK Prevents Steatosis on a High-Fructose Diet

    Directory of Open Access Journals (Sweden)

    Angela Woods

    2017-03-01

    Full Text Available AMP-activated protein kinase (AMPK plays a key role in integrating metabolic pathways in response to energy demand. We identified a mutation in the γ1 subunit (γ1D316A that leads to activation of AMPK. We generated mice with this mutation to study the effect of chronic liver-specific activation of AMPK in vivo. Primary hepatocytes isolated from these mice have reduced gluconeogenesis and fatty acid synthesis, but there is no effect on fatty acid oxidation compared to cells from wild-type mice. Liver-specific activation of AMPK decreases lipogenesis in vivo and completely protects against hepatic steatosis when mice are fed a high-fructose diet. Our findings demonstrate that liver-specific activation of AMPK is sufficient to protect against hepatic triglyceride accumulation, a hallmark of non-alcoholic fatty liver disease (NAFLD. These results emphasize the clinical relevance of activating AMPK in the liver to combat NAFLD and potentially other associated complications (e.g., cirrhosis and hepatocellular carcinoma.

  19. Synthesis of glycolic acid-1-14C of high specific activity

    International Nuclear Information System (INIS)

    Ramamurthy, T.V.; Viswanathan, K.V.

    1987-01-01

    A simple procedure is described which efficiently converts traces of 14 C labelled cyanide present as a dilute solution into glycolic acid-1- 14 C with more than 85% radiochemical recovery and of high specific activity. (author)

  20. The PPAR{gamma} ligand ciglitazone regulates androgen receptor activation differently in androgen-dependent versus androgen-independent human prostate cancer cells

    Energy Technology Data Exchange (ETDEWEB)

    Moss, Patrice E.; Lyles, Besstina E.; Stewart, LaMonica V., E-mail: lstewart@mmc.edu

    2010-12-10

    The androgen receptor (AR) regulates growth and progression of androgen-dependent as well as androgen-independent prostate cancer cells. Peroxisome proliferator-activated receptor gamma (PPAR{gamma}) agonists have been reported to reduce AR activation in androgen-dependent LNCaP prostate cancer cells. To determine whether PPAR{gamma} ligands are equally effective at inhibiting AR activity in androgen-independent prostate cancer, we examined the effect of the PPAR{gamma} ligands ciglitazone and rosiglitazone on C4-2 cells, an androgen- independent derivative of the LNCaP cell line. Luciferase-based reporter assays and Western blot analysis demonstrated that PPAR{gamma} ligand reduced dihydrotestosterone (DHT)-induced increases in AR activity in LNCaP cells. However, in C4-2 cells, these compounds increased DHT-induced AR driven luciferase activity. In addition, ciglitazone did not significantly alter DHT-mediated increases in prostate specific antigen (PSA) protein or mRNA levels within C4-2 cells. siRNA-based experiments demonstrated that the ciglitazone-induced regulation of AR activity observed in C4-2 cells was dependent on the presence of PPAR{gamma}. Furthermore, overexpression of the AR corepressor cyclin D1 inhibited the ability of ciglitazone to induce AR luciferase activity in C4-2 cells. Thus, our data suggest that both PPAR{gamma} and cyclin D1 levels influence the ability of ciglitazone to differentially regulate AR signaling in androgen-independent C4-2 prostate cancer cells.

  1. Decontamination Experiments on Intact Pig Skin Contaminated with Beta-Gamma- Emitting Nuclides

    Energy Technology Data Exchange (ETDEWEB)

    Edvardsson, K A; Hagsgaard, S [AB Atomenergi, Nykoeping (Sweden); Swensson, A [Dept. of Occupational Medicine, Karolinska Sjukhuset, Stockholm (Sweden)

    1966-11-15

    A number of decontamination experiments have been performed on intact pig skin. In most of the experiments NaI-131 in water solution has been utilized because this nuclide is widely used within the Studsvik research establishment, is easy to detect and relatively harmless, and is practical to use in these experiments. Among the {beta} {gamma}-nuclides studied 1-131 has furthermore proved to be the one most difficult to remove from the skin. The following conclusions and recommendations regarding the decontamination of skin are therefore valid primarily for iodine in the form of Nal, but are probably also applicable to many other {beta} {gamma}-nuclides. a) A prolonged interval between contamination and decontamination has a negative effect on the result of the decontamination. Therefore start decontamination as soon as possible after the contamination. b) Soap and water has proved to be the most suitable decontamination agent. A number of other agents have appeared to be harmful to the skin. Therefore, first of all use only soap and water in connection with gentle rubbing. c) No clear connection between the temperature of the water for washing and the result of the decontamination has been demonstrated. d) Skin not degreased before the contamination seems to be somewhat easier to decontaminate than degreased skin, particularly if the activity has been on the skin for a long time. Therefore do not remove the sebum of the skin when engaged on radioactive work involving contamination risks. e) Irrigation of the contaminated surface with a solution containing the corresponding inactive ions or ordinary water in large quantities may considerably decrease the skin contamination. f) In radioactive work of long duration involving high risks of contamination prophylactic measures in the form of a protective substance ('invisible glove'), type Kerodex, may make decontamination easier.

  2. EJ-309 pulse shape discrimination performance with a high gamma-ray-to-neutron ratio and low threshold

    Energy Technology Data Exchange (ETDEWEB)

    Kaplan, A.C., E-mail: Alexis.C.Kaplan@gmail.com [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, 2355 Bonisteel Blvd., Ann Arbor, MI 48104 (United States); Nuclear Engineering and Nonproliferation Division, Los Alamos National Laboratory, Los Alamos, NM 87544 (United States); Flaska, M.; Enqvist, A.; Dolan, J.L.; Pozzi, S.A. [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, 2355 Bonisteel Blvd., Ann Arbor, MI 48104 (United States)

    2013-11-21

    Measuring neutrons in the presence of high gamma-ray fluence is a challenge with multi-particle detectors. Organic liquid scintillators such as the EJ-309 are capable of accurate pulse-shape discrimination (PSD) but the chance for particle misclassification is not negligible for some applications. By varying the distance from an EJ-309 scintillator to a strong-gamma-ray source and keeping a weak-neutron source at a fixed position, various gamma-to-neutron ratios can be measured and PSD performance can be quantified. Comparing neutron pulse-height distributions allows for pulse-height specific PSD evaluation, and quantification and visualization of deviation from {sup 252}Cf alone. Even with the addition of the misclassified gamma-rays, the PSD is effective in separating particles so that neutron count rate can be predicted with less than 10% error up to a gamma-to-neutron ratio of almost 650. For applications which can afford a reduction in neutron detection efficiency, PSD can be sufficiently effective in discriminating particles to measure a weak neutron source in a high gamma-ray background. -- Highlights: •We measure neutrons in a high photon background with EJ-309 liquid scintillators. •A low threshold is used to test the limits of particle discrimination. •A weak neutron signal is detectable with a gamma/neutron ratio as high as 770. •Photon pileup most commonly adds to error in classification of neutrons. •Neutron count rates are within 10% of expected rate under high gamma background.

  3. EJ-309 pulse shape discrimination performance with a high gamma-ray-to-neutron ratio and low threshold

    International Nuclear Information System (INIS)

    Kaplan, A.C.; Flaska, M.; Enqvist, A.; Dolan, J.L.; Pozzi, S.A.

    2013-01-01

    Measuring neutrons in the presence of high gamma-ray fluence is a challenge with multi-particle detectors. Organic liquid scintillators such as the EJ-309 are capable of accurate pulse-shape discrimination (PSD) but the chance for particle misclassification is not negligible for some applications. By varying the distance from an EJ-309 scintillator to a strong-gamma-ray source and keeping a weak-neutron source at a fixed position, various gamma-to-neutron ratios can be measured and PSD performance can be quantified. Comparing neutron pulse-height distributions allows for pulse-height specific PSD evaluation, and quantification and visualization of deviation from 252 Cf alone. Even with the addition of the misclassified gamma-rays, the PSD is effective in separating particles so that neutron count rate can be predicted with less than 10% error up to a gamma-to-neutron ratio of almost 650. For applications which can afford a reduction in neutron detection efficiency, PSD can be sufficiently effective in discriminating particles to measure a weak neutron source in a high gamma-ray background. -- Highlights: •We measure neutrons in a high photon background with EJ-309 liquid scintillators. •A low threshold is used to test the limits of particle discrimination. •A weak neutron signal is detectable with a gamma/neutron ratio as high as 770. •Photon pileup most commonly adds to error in classification of neutrons. •Neutron count rates are within 10% of expected rate under high gamma background

  4. Highly efficient greenish-blue platinum-based phosphorescent organic light-emitting diodes on a high triplet energy platform

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Y. L., E-mail: yilu.chang@mail.utoronto.ca; Gong, S., E-mail: sgong@chem.utoronto.ca; White, R.; Lu, Z. H., E-mail: zhenghong.lu@utoronto.ca [Department of Materials Science and Engineering, University of Toronto, 184 College St., Toronto, Ontario M5S 3E4 (Canada); Wang, X.; Wang, S., E-mail: wangs@chem.queensu.ca [Department of Chemistry, Queen' s University, 90 Bader Lane, Kingston, Ontario K7L 3N6 (Canada); Yang, C. [Department of Chemistry, Wuhan University, Wuhan 430072 (China)

    2014-04-28

    We have demonstrated high-efficiency greenish-blue phosphorescent organic light-emitting diodes (PHOLEDs) based on a dimesitylboryl-functionalized C^N chelate Pt(II) phosphor, Pt(m-Bptrz)(t-Bu-pytrz-Me). Using a high triplet energy platform and optimized double emissive zone device architecture results in greenish-blue PHOLEDs that exhibit an external quantum efficiency of 24.0% and a power efficiency of 55.8 lm/W. This record high performance is comparable with that of the state-of-the-art Ir-based sky-blue organic light-emitting diodes.

  5. Resting-state beta and gamma activity in Internet addiction.

    Science.gov (United States)

    Choi, Jung-Seok; Park, Su Mi; Lee, Jaewon; Hwang, Jae Yeon; Jung, Hee Yeon; Choi, Sam-Wook; Kim, Dai Jin; Oh, Sohee; Lee, Jun-Young

    2013-09-01

    Internet addiction is the inability to control one's use of the Internet and is related to impulsivity. Although a few studies have examined neurophysiological activity as individuals with Internet addiction engage in cognitive processing, no information on spontaneous EEG activity in the eyes-closed resting-state is available. We investigated resting-state EEG activities in beta and gamma bands and examined their relationships with impulsivity among individuals with Internet addiction and healthy controls. Twenty-one drug-naïve patients with Internet addiction (age: 23.33 ± 3.50 years) and 20 age-, sex-, and IQ-matched healthy controls (age: 22.40 ± 2.33 years) were enrolled in this study. Severity of Internet addiction was identified by the total score on Young's Internet Addiction Test. Impulsivity was measured with the Barratt Impulsiveness Scale-11 and a stop-signal task. Resting-state EEG during eyes closed was recorded, and the absolute/relative power of beta and gamma bands was analyzed. The Internet addiction group showed high impulsivity and impaired inhibitory control. The generalized estimating equation showed that the Internet-addiction group showed lower absolute power on the beta band than did the control group (estimate = -3.370, p Internet-addiction group showed higher absolute power on the gamma band than did the control group (estimate = 0.434, p Internet addiction as well as with the extent of impulsivity. The present study suggests that resting-state fast-wave brain activity is related to the impulsivity characterizing Internet addiction. These differences may be neurobiological markers for the pathophysiology of Internet addiction. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Studied by electron paramagnetic resonance (EPR) of polymethyl methacrylate (PMMA) irradiated with gamma photons from cobalt 60

    International Nuclear Information System (INIS)

    Jalali, Hajer

    2013-01-01

    Ionizing radiation is radiation able to deposit enough energy in the material through which they pass to create ionization. These ionizing radiations, when mastered, have many practical uses beneficial (areas of health, industry ...). Gamma rays are emitted by radioactive nuclei. The objective of our work is the study of polymethyl methacrylate (PMMA) irradiated by gamma photons from cobalt-60. To study the technique of radio spectroscopy (9 to 10Hz) electron paramagnetic resonance EPR is used. This technique is specific to characterize transient free radicals involved in chemical reactions such as oxidation, combustion, polymerization reactions ... We analyzed the EPR spectra three batch KS, EB, and JF our dosimeter according to the dose (high and low) and showed that the dosimetric response can be represented in exponential form (high dose) and linear form (low dose). We also studied the kinetics of decay of the EPR signal as a function of time (fading) and showed that the responses relating to stabilize after 20 min of irradiation.

  7. High power ultraviolet light emitting diodes based on GaN/AlGaN quantum wells produced by molecular beam epitaxy

    International Nuclear Information System (INIS)

    Cabalu, J. S.; Bhattacharyya, A.; Thomidis, C.; Friel, I.; Moustakas, T. D.; Collins, C. J.; Komninou, Ph.

    2006-01-01

    In this paper, we report on the growth by molecular beam epitaxy and fabrication of high power nitride-based ultraviolet light emitting diodes emitting in the spectral range between 340 and 350 nm. The devices were grown on (0001) sapphire substrates via plasma-assisted molecular beam epitaxy. The growth of the light emitting diode (LED) structures was preceded by detailed materials studies of the bottom n-AlGaN contact layer, as well as the GaN/AlGaN multiple quantum well (MQW) active region. Specifically, kinetic conditions were identified for the growth of the thick n-AlGaN films to be both smooth and to have fewer defects at the surface. Transmission-electron microscopy studies on identical GaN/AlGaN MQWs showed good quality and well-defined interfaces between wells and barriers. Large area mesa devices (800x800 μm 2 ) were fabricated and were designed for backside light extraction. The LEDs were flip-chip bonded onto a Si submount for better heat sinking. For devices emitting at 340 nm, the measured differential on-series resistance is 3 Ω with electroluminescence spectrum full width at half maximum of 18 nm. The output power under dc bias saturates at 0.5 mW, while under pulsed operation it saturates at approximately 700 mA to a value of 3 mW, suggesting that thermal heating limits the efficiency of these devices. The output power of the investigated devices was found to be equivalent with those produced by the metal-organic chemical vapor deposition and hydride vapor-phase epitaxy methods. The devices emitting at 350 nm were investigated under dc operation and the output power saturates at 4.5 mW under 200 mA drive current

  8. Experimental arrangement for production and use of gamma radiation from neutron capture

    International Nuclear Information System (INIS)

    Mafra, Olga Yajgunovitch

    1969-01-01

    This dissertation presents the main characteristics and construction details of collimator system for gamma radiation emitted by atomic nuclei after capturing thermal neutrons. This construction was made in one of the cross channels of IEAR-1 swimming pool reactor of the Atomic Energy Institute of Sao Paulo, Brazil. The energies of gamma radiation available vary range from about 4 MeV and 11 MeV, discreetly. With this experimental arrangement is obtained: high intensity, good collimation and monochrome gamma radiation, important for conducting experiments with gamma radiation. It is also present in this dissertation the description of the techniques employed in determining the intensity of gamma radiation and the extent of contamination in the neutron beam as well as the program list GAMAU that adjusts the gamma spectrum photopeak taken as a Gaussian curve. We intend to use this experimental arrangement for the measurement of cross sections of photonuclear reactions

  9. Ore sorting using natural gamma radiation

    International Nuclear Information System (INIS)

    Clark, G.J.; Dickson, B.L.; Gray, F.E.

    1980-01-01

    A method of sorting an ore which emits natural gamma radiation is described, comprising the steps of: (a) mining the ore, (b) placing, substantially at the mining location, the sampled or mined ore on to a moving conveyor belt, (c) measuring the natural gamma emission, water content and mass of the ore while the ore is on the conveyor belt, (d) using the gamma, water content and mass measurements to determine the ore grade, and (e) directing the ore to a location characteristic of its grade when it leaves the conveyor belt

  10. Results from the first national in-situ gamma spectrometry survey of the United Kingdom

    International Nuclear Information System (INIS)

    Tyler, A.

    2004-01-01

    In-situ gamma spectrometry was introduced for the first time as part of a national soil and herbage pollution survey of the United Kingdom (UK) in 2002. The aim of introducing the in-situ approach was to evaluate its potential for replacing the conventional soil sampling approach in environmental monitoring. A total of 138 points were measured across the whole of the UK on a 50 km grid, encompassing a complete spectrum of soil types, geology (providing a range of natural radioactive backgrounds) and anthropogenic radioactivity (primarily derived from atmospheric weapons testing and Chernobyl fallout). Ten calibration sites were set up to derive an in-situ calibration from spatially distributed sampling points, designed to match the spatial response of the in-situ detector at 1 m above the ground. The importance of variations in the vertical activity distributions of 137 Cs on the in-situ detector calibration was verified and the advantages and disadvantages of implementing a forward scattering type approach for real time in-situ correction was evaluated. The accuracy of the in-situ calibrations was evaluated for the remaining 128 sites by independent comparison with soil core derived estimates of specific activity concentrations and inventories of a range of natural and anthropogenic gamma emitting radionuclides. Air kerma measurements were also derived from the in-situ gamma spectrometry measurements and compared with conventional GM tube derived estimates. (authors)

  11. Study of the /sup 233/Th(. gamma. ,xn)226,222/supTh/ reaction at. gamma. -energies <= 60 MeV using a helium jet

    Energy Technology Data Exchange (ETDEWEB)

    Jungclas, H

    1974-01-01

    A helium jet system is set up for the transport and investigation of daughter products of the nuclear reaction /sup 232/Th (..gamma..,xn) at E/sub..gamma../<=60 MeV. The theoretical fundamentals for the target kinematics such as photoexcitation, evaporation cascade and range of heavy ions are presented. Activation experiments with thick thorium tetrafluoride targets and catcher foils for the reaction products emitted showed a nuclide-dependent forwards-backwards ratio which agrees with the calculated values within 1-2 standard deviations of the statistic error. A target system with thorium nitrate coated glass wool is tested with the helium in 'on-line' operation and after irradiation is used for the investigation of the long-lived activities with the excess pressure jet. The radioactive decay series of the transported reaction products are identified by alpha spectroscopy.

  12. GEANT4 simulation study of a gamma-ray detector for neutron resonance densitometry

    International Nuclear Information System (INIS)

    Tsuchiya, Harufumi; Harada, Hideo; Koizumi, Mitsuo; Kitatani, Fumito; Takamine, Jun; Kureta, Masatoshi; Iimura, Hideki

    2013-01-01

    A design study of a gamma-ray detector for neutron resonance densitometry was made with GEANT4. The neutron resonance densitometry, combining neutron resonance transmission analysis and neutron resonance capture analysis, is a non-destructive technique to measure amounts of nuclear materials in melted fuels of the Fukushima Daiichi nuclear power plants. In order to effectively quantify impurities in the melted fuels via prompt gamma-ray measurements, a gamma-ray detector for the neutron resonance densitometry consists of cylindrical and well type LaBr 3 scintillators. The present simulation showed that the proposed gamma-ray detector suffices to clearly detect the gamma rays emitted by 10 B(n, αγ) reaction in a high environmental background due to 137 Cs radioactivity with its Compton edge suppressed at a considerably small level. (author)

  13. Study, simulation and modelling of a gamma photon detector placed on an integral-type eccentric orbit

    International Nuclear Information System (INIS)

    Diallo, N.

    1999-01-01

    Gamma-ray lines are the signature of nuclear reactions and other high-energy processes that take place in the Universe. Their measurement and study provide invaluable information on many important problems in high energy astrophysics, including particle acceleration, physics of compact objects and nucleosynthesis. However the observation of astronomical gamma-ray sources has to be performed above the atmosphere because the Earth's atmosphere is opaque to gamma-rays. Unfortunately at these altitudes, spatial high energy electromagnetic radiation (X and gamma rays) detectors are exposed to intense parasite fluxes of radiation and particles induced by primary galactic cosmic rays. These fluxes as well radiation and secondary particles they generate, constitute a considerable source of background which limits their performances. Our study has been done in the framework of the INTEGRAL mission, a gamma-ray astronomy mission of the European Space Agency. INTEGRAL is devoted to the observation of celestial gamma-ray sources. It consists of two main instruments: an imager IBIS and a high resolution germanium spectrometer SPI (ΔE/E = 1.6 10 -3 at 1.3 MeV). We studied the hadronic component of the SPI background. This component is due to the radioactive decay of unstable nuclides produced by the interactions of cosmic-ray protons with the materials of SPI. It consists of a continuum with gamma ray lines superimposed. To study nuclear processes, Monte Carlo simulations have been performed with the nuclear code TIERCE developed at CEA/DAM. We used the GEANT Monte Carlo code developed at CERN to simulate the germanium detectors response. Background reduction techniques as PSD (Pulse Shape Discrimination) and energetic signatures have been applied in well chosen energy ranges to reduce the background. and improve the SPI sensitivity. With the estimated SPI narrow-line sensitivity level, SPI would be able to detect many gamma ray limes emitted in the active galactic sites

  14. Effect of Dopant Activation on Device Characteristics of InGaN-based Light Emitting Diodes

    Science.gov (United States)

    Lacroce, Nicholas; Liu, Guangyu; Tan, Chee-Keong; Arif, Ronald A.; Lee, Soo Min; Tansu, Nelson

    2015-03-01

    Achieving high uniformity in growths and device characteristics of InGaN-based light-emitting diodes (LEDs) is important for large scale manufacturing. Dopant activation and maintaining control of variables affecting dopant activation are critical steps in the InGaN-based light emitting diodes (LEDs) fabrication process. In the epitaxy of large scale production LEDs, in-situ post-growth annealing is used for activating the Mg acceptor dopant in the p-AlGaN and p-GaN of the LEDs. However, the annealing temperature varies with respect to position in the reactor chamber, leading to severe uniform dopant activation issue across the devices. Thus, it is important to understand how the temperature gradient and the resulting variance in Mg acceptor activation will alter the device properties. In this work, we examine the effect of varying p-type doping levels in the p-GaN layers and AlGaN electron blocking layer of the GaN LEDs on the optoelectronic properties including the band profile, carrier concentration, current density, output power and quantum efficiency. By understanding the variations and its effect, the identification of the most critical p-type doping layer strategies to address this variation will be clarified.

  15. A new method for studying the transport of gamma photons in various geological materials by combining the SSNTD technique with Monte Carlo simulations

    International Nuclear Information System (INIS)

    Misdaq, M.A.; Merzouki, A.; Bourzik, W.; Sfairi, T.

    2000-01-01

    The gamma dose rate due to the uranium and thorium series as well as the potassium 40 nuclei represents a large fraction of the total dose rate from the natural background. Natural gamma-activities of rock and soil samples collected from volcanic areas have been determined using gamma-ray spectrometry. The corresponding gamma dose rates in air have been measured by means of thermoluminescence (TL) dosimeters. Annual absorbed gamma dose rates have been evaluated in different soil samples belonging to an archaeological site by using experimental and calculational methods. Uranium and thorium contents in different geological samples have been determined by using CR-39 and LR-115 type II solid state nuclear track detectors (SSNTD) and calculating the probabilities for alpha particles emitted by the uranium and thorium series to reach and be registered on the SSNTD films. A new method has been developed based on calculating the self-absorption and transmission coefficients of the gamma photons emitted by the uranium and thorium families as well as the potassium 40 isotope for evaluating the gamma dose rate in the considered geological samples. Transport of gamma-photons across parallelepipedic blocks of the geological materials studied has been investigated. Gamma dose rates have been evaluated in the atmosphere of different geological deposits. (author)

  16. The Multi-Messenger Approach to High-Energy Gamma-Ray Sources

    CERN Document Server

    Paredes, Josep M; Torres, Diego F

    2008-01-01

    This book provides a theoretical and observational overview of the state of the art of gamma-ray astrophysics, and their impact and connection with the physics of cosmic rays and neutrinos. With the aim of shedding new and fresh light on the problem of the nature of the gamma-ray sources, particularly those yet unidentified, this book summarizes contributions to a workshop that continues with the series initiated by the meeting held at Tonantzintla in October 2000, and Hong-Kong in May 2004. This books will be of interest for all active researchers in the field of high energy astrophysics and astroparticle physics, as well as for graduate students entering into the subject.

  17. Use of MCNP + GADRAS in Generating More Realistic Gamma-Ray Spectra for Plutonium and HEU Objects

    International Nuclear Information System (INIS)

    Rawool-Sullivan, Mohini; Mattingly, John; Mitchell, Dean

    2012-01-01

    The ability to accurately simulate high-resolution gamma spectra from materials that emit both neutrons and gammas is very important to the analysis of special nuclear materials (SNM), e.g., uranium and plutonium. One approach under consideration has been to combine MCNP and GADRAS. This approach is expected to generate more accurate gamma ray spectra for complex three-dimensional geometries than can be obtained from one-dimensional deterministic transport simulations (e.g., ONEDANT). This presentation describes application of combining MCNP and GADRAS in simulating plutonium and uranium spectra.

  18. PARP-1 is a key player in controlling apoptosis induced by high LET carbon ion beam and low LET gamma radiation in HeLa cells

    International Nuclear Information System (INIS)

    Ghorai, Atanu; Ghosh, Utpal; Bhattacharyya, Nitai P.; Sarma, Asitikantha

    2014-01-01

    PARP-1 inhibitors have long been used as chemo-sensitizer or radio-sensitizer and specific PARP-1 inhibitors are also in clinical trial for the treatment of various cancers. PARP-1 is not only involved in DNA repair but also plays very complex role in induction of apoptosis in postirradiation condition. Our objective is to investigate role of PARP-1 in apoptosis triggered by high LET carbon ion beam (CIB) and low LET gamma. We have treated HeLa and PARP-1 knock down HeLa (Hsil) cells with various doses of CIB and gamma. We measured DNA damage by comet assay and various apoptotic parameters such as nuclear fragmentation, activation of caspase-3,8,9, AIF translocation etc. We observed higher DNA breaks and also higher apoptosis in HsiI cells compared with HeLa cells. Both CIB and gamma treatment results G2/M arrest but unlike gamma CIB makes S-phase delay, implicating that gamma and CIB triggers different pathway after DNA damage. Cell death by CIB or by gamma increased up on knocking down of PARP-1 but increase is higher for high LET CIB compared with low LET gamma. Furthermore, expression level of PARP-1 controls the intensity of overall apoptosis in cells in post-irradiation condition. So, combination of PARP-1 inhibition with high LET CIB could be a promising tool to combat cancer. (author)

  19. Enhanced stimulus-induced gamma activity in humans during propofol-induced sedation.

    Directory of Open Access Journals (Sweden)

    Neeraj Saxena

    Full Text Available Stimulus-induced gamma oscillations in the 30-80 Hz range have been implicated in a wide number of functions including visual processing, memory and attention. While occipital gamma-band oscillations can be pharmacologically modified in animal preparations, pharmacological modulation of stimulus-induced visual gamma oscillations has yet to be demonstrated in non-invasive human recordings. Here, in fifteen healthy humans volunteers, we probed the effects of the GABAA agonist and sedative propofol on stimulus-related gamma activity recorded with magnetoencephalography, using a simple visual grating stimulus designed to elicit gamma oscillations in the primary visual cortex. During propofol sedation as compared to the normal awake state, a significant 60% increase in stimulus-induced gamma amplitude was seen together with a 94% enhancement of stimulus-induced alpha suppression and a simultaneous reduction in the amplitude of the pattern-onset evoked response. These data demonstrate, that propofol-induced sedation is accompanied by increased stimulus-induced gamma activity providing a potential window into mechanisms of gamma-oscillation generation in humans.

  20. High-energy {gamma}-irradiation effect on physical ageing in Ge-Se glasses

    Energy Technology Data Exchange (ETDEWEB)

    Golovchak, R. [Lviv Scientific Research Institute of Materials of SRC ' Carat' , 202 Stryjska Str., Lviv, UA-79031 (Ukraine); Kozdras, A. [Department of Physics of Opole University of Technology, 75 Ozimska Str., Opole, PL-45370 (Poland); Department of Economy of Academy of Management and Administration in Opole, 18 Niedzialkowski Str., Opole, PL-45085 (Poland); Kozyukhin, S. [Institute of General and Inorganic Chemistry of RAS, Leninsky Pr. 31, Moscow 199991 (Russian Federation); Shpotyuk, O. [Lviv Scientific Research Institute of Materials of SRC ' Carat' , 202 Stryjska Str., Lviv, UA-79031 (Ukraine); Institute of Physics of Jan Dlugosz University, 13/15 al. Armii Krajowej, Czestochowa, PL-42201 (Poland)], E-mail: shpotyuk@novas.lviv.ua

    2009-09-01

    Effect of Co{sup 60} {gamma}-irradiation on physical ageing in binary Ge{sub x}Se{sub 100-x} glasses (5 {<=} x {<=} 27) is studied using conventional differential scanning calorimetry method. It is shown, that high-energy irradiation leads to additional increase in the glass transition temperature and endothermic peak area near the glass transition region over the one induced by isochronal storage of these glasses at normal conditions. This {gamma}-induced physical ageing is shown to be well-pronounced in Se-rich glasses (x < 20), while only negligible changes are recorded for glasses of 20 {<=} x {<=} 27 compositions. The effect under consideration is supposed to be associated with {gamma}-activated structural relaxation of the glass network towards thermodynamic equilibrium of supercooled liquid.

  1. Natural gamma ray spectrum analysis technique

    International Nuclear Information System (INIS)

    Chevalier, P.; Seeman, B.

    1976-01-01

    In accordance with an illustrative embodiment of the present invention, a method and apparatus is disclosed for determining the presence of a selected number of naturally radioactive materials in an earth formation from the spectrum of natural gamma radiation emitted by the materials in the formation by deriving representations of portions of the detected gamma radiation spectrum and combining the representations to determine therefrom the presence of the selected materials

  2. Echolocating bats emit a highly directional sonar sound beam in the field

    DEFF Research Database (Denmark)

    Surlykke, Annemarie; Boel Pedersen, Simon; Jakobsen, Lasse

    2009-01-01

    Bats use echolocation or biosonar to navigate and find prey at night. They emit short ultrasonic calls and listen for reflected echoes. The beam width of the calls is central to the function of the sonar, but directionality of echolocation calls has never been measured from bats flying in the wild....... We used a microphone array to record sounds and determine horizontal directionality for echolocation calls of the trawling Daubenton's bat, Myotis daubentonii, flying over a pond in its natural habitat. Myotis daubentonii emitted highly directional calls in the field. Directionality increased...... and directionality can be explained by the simple piston model. The model also suggests that the increase in the emitted intensity in the field is caused by the increased directionality, focusing sound energy in the forward direction. The bat may increase directionality by opening the mouth wider to emit a louder...

  3. Performance of analytical methods for tomographic gamma scanning

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Mercer, D.J.

    1997-01-01

    The use of gamma-ray computerized tomography for nondestructive assay of radioactive materials has led to the development of specialized analytical methods. Over the past few years, Los Alamos has developed and implemented a computer code, called ARC-TGS, for the analysis of data obtained by tomographic gamma scanning (TGS). ARC-TGS reduces TGS transmission and emission tomographic data, providing the user with images of the sample contents, the activity or mass of selected radionuclides, and an estimate of the uncertainty in the measured quantities. The results provided by ARC-TGS can be corrected for self-attenuation when the isotope of interest emits more than one gamma-ray. In addition, ARC-TGS provides information needed to estimate TGS quantification limits and to estimate the scan time needed to screen for small amounts of radioactivity. In this report, an overview of the analytical methods used by ARC-TGS is presented along with an assessment of the performance of these methods for TGS

  4. External exposure doses due to gamma emitting natural radionuclides in some Egyptian building materials.

    Science.gov (United States)

    Moharram, B M; Suliman, M N; Zahran, N F; Shennawy, S E; El Sayed, A R

    2012-01-01

    Using of building materials containing naturally occurring radionuclides as (238)U, (232)Th and (40)K and their progeny results in an external exposures of the housing of such buildings. In the present study, indoor dose rates for typical Egyptian rooms are calculated using the analytical method and activity concentrations of natural radionuclides in some building materials. Uniform chemical composition of the walls, floor and ceiling as well as uniform mass concentrations of the radionuclides in walls, floor and ceiling assumed. Different room models are assumed to discuss variation of indoor dose rates according to variation in room construction. Activity concentrations of (238)U, (232)Th and (40)K content in eight samples representative Clay soil and different building materials used in most recent Egyptian building were measured using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). The specific activity for (238)U, (232)Th and (40)K, from the selected samples, were in the range 14.15-60.64, 2.75-84.66 and 7.35-554.4Bqkg(-1), respectively. The average indoor absorbed dose rates in air ranged from 0.005μGyh(-1) to 0.071μGyh(-1) and the corresponding population-weighted annual effective dose due to external gamma radiation varies from 0.025 to 0.345mSv. An outdoor dose rate for typical building samples in addition to some radiological hazards has been introduced for comparison. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Measurement and Analysis of Specific Activities of Natural Radionuclides (40K, 226Ra and 232Th) in Beach Sand Samples from Talo Kapo Beach of Yaring District in Pattani Province using Gamma Ray Spectrometry

    Science.gov (United States)

    Daoh, M.; Masae, R. N.; Po-oh, S.; Boonkrongcheep; Kessaratikoon, P.

    2017-09-01

    The Specific Activities of 40K, 226Ra and 232Th were studied and determinate for 30 beach sand samples collected from Talo Kapo beach of Yaring district in Pattani province. Experimental results were obtained by using a high-purity germanium (HPGe) detector and gamma spectrometry analysis system. The IAEA-SOIL-6 reference materials obtained from the International Atomic Energy Agency were also used to analyze and compute the 40K, 226Ra and 232Th specific activity in all 30 beach sand samples. The measuring time of each sample is 10,000 seconds. It was found that specific activity range from 1805.37 - 3323.05, 40.96 - 2137.36 38.63 - 4329.28 Bq/kg for with mean values of 2242.79 ± 117.40, 250.18 ± 8.21 and 458.42 ± 7.68 Bq/kg for 40K, 226Ra and 232Th, respectively. Moreover, the results were also compared with research data in the south of Thailand, the Office of Atoms for Peace (OAP) annual report data and the recommended values which were proposed by United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR,)

  6. Variation of Neutron Moderating Power on HDPE by Gamma Radiation

    International Nuclear Information System (INIS)

    Park, Kwang June; Ju, June Sik; Kang, Hee Young; Shin, Hee Sung; Kim, Ho Dong

    2009-01-01

    High density polyethylene (HDPE) is degraded due to a radiation-induced oxidation when it is used as a neutron moderator in a neutron counter for a nuclear material accounting of spent fuels. The HDPE exposed to the gamma-ray emitted from the fission products in a spent nuclear fuel results in a radiation-induced degradation which changes its original molecular structure to others. So a neutron moderating power variation of HDPE, irradiated by a gamma radiation, was investigated in this work. Five HDPE moderator structures were exposed to the gamma radiation emitted from a 60 Co source to a level of 10 5 -10 9 rad to compare their post-irradiation properties. As a result of the neutron measurement test with 5 irradiated HDPE structures and a neutron measuring system, it was confirmed that the neutron moderating power for the 105 rad irradiated HDPE moderator revealed the largest decrease when the un-irradiated pure one was used as a reference. It implies that a neutron moderating power variation of HDPE is not directly proportional to the integrated gamma dose rate. To clarify the cause of these changes, some techniques such as a FTIR, an element analysis and a densitometry were employed. As a result of these analyses, it was confirmed that the molecular structure of the gamma irradiated HDPEs had partially changed to others, and the contents of hydrogen and oxygen had varied during the process of a radiation-induced degradation. The mechanism of these changes cannot be explained in detail at present, and thus need further study

  7. Mechanism of action for anti-radiation vaccine in reducing the biological impact of high-dose gamma irradiation

    Science.gov (United States)

    Maliev, Vladislav; Popov, Dmitri; Jones, Jeffrey A.; Casey, Rachael C.

    Ionizing radiation is a major health risk of long-term space travel, the biological consequences of which include genetic and oxidative damage. In this study, we propose an original mechanism by which high doses of ionizing radiation induce acute toxicity. We identified biological components that appear in the lymphatic vessels shortly after high-dose gamma irradiation. These radiation-induced toxins, which we have named specific radiation determinants (SRD), were generated in the irradiated tissues and then circulated throughout the body via the lymph circulation and bloodstream. Depending on the type of SRD elicited, different syndromes of acute radiation sickness (ARS) were expressed. The SRDs were developed into a vaccine used to confer active immunity against acute radiation toxicity in immunologically naïve animals. Animals that were pretreated with SRDs exhibited resistance to lethal doses of gamma radiation, as measured by increased survival times and survival rates. In comparison, untreated animals that were exposed to similar large doses of gamma radiation developed acute radiation sickness and died within days. This phenomenon was observed in a number of mammalian species. Initial analysis of the biochemical characteristics indicated that the SRDs were large molecular weight (200-250 kDa) molecules that were comprised of a mixture of protein, lipid, carbohydrate, and mineral. Further analysis is required to further identify the SRD molecules and the biological mechanism by which they mediate the toxicity associated with acute radiation sickness. By doing so, we may develop an effective specific immunoprophylaxis as a countermeasure against the acute effects of ionizing radiation.

  8. A model problem for restricted-data gamma ray emission tomography of highly active nuclear waste

    International Nuclear Information System (INIS)

    Cattle, Brian A.

    2007-01-01

    This paper develops the work of Cattle et al. [Cattle, B.A., Fellerman, A.S., West, R.M., 2004. On the detection of solid deposits using gamma ray emission tomography with limited data. Measurement Science and Technology 15, 1429-1439] by considering a generalization of the model employed therein. The focus of the work is the gamma ray tomographic analysis of high-level waste processing. The work in this paper considers a two-dimensional model for the measurement of gamma ray photon flux, as opposed to the previous one-dimensional analysis via the integrated Beer-Lambert law. The mathematical inverse problem that arises in determining physical quantities from the photon count measurements is tackled using Bayesian statistical methods that are implemented computationally using a Markov chain Monte Carlo (MCMC) approach. In a further new development, the effect of the degree of collimation of the detector on the reliability of the solutions is also considered

  9. A high rate gamma spectroscopy system for activation analysis of short lived isomeric transitions

    Energy Technology Data Exchange (ETDEWEB)

    Westphal, G P [Atominstitut, Vienna (Austria)

    1976-07-01

    A high rate spectroscopy system specially suited for measurement of short-lived isomeric transitions is described, which, as part of a fast activation analysis facility at the TRIGA Mark II reactor, provides for automatic recording and immediate evaluation of gamma spectra taken from nuclides activated at stationary or pulsed reactor power. The system consists of a commercial DC-coupled Ge(Li)-detector of 70 cm{sup 3} modified for recycling operation for input rates in excess of 500,000 c/s Co-60, a time variant trapezoidal shaping section and a fast constant dead-time ADC coupled to a programmed multi-channel analyzer. Novel circuits for efficient pile-up rejection and time variant base line restoration extend the concept of gated integration up to count rates of more than 300,000 c/s Co-60. Time-sequenced recording of spectra is performed by a mini computer operated as a front-end processor of a larger laboratory computer, where final data processing takes place. New concepts for very simple and cost-effective implementation of multi-channel analyzers by means of general purpose small computers are described. (author)

  10. Production of sealed sup 6 sup 0 Co and sup 1 sup 9 sup 2 Ir sources of high specific activity in the nuclear reactor RA

    International Nuclear Information System (INIS)

    Dobrijevic, R.; Vucina, J.

    1998-01-01

    Given is a review on the development of the production of 60 Co and 192 Ir performed in the Vinca Institute in the nuclear reactor RA. The experience gained showed that this reactor was suitable for obtaining of these and some other radionuclides. One possibility of its re-start is that the performances of the reactor remain the same (power 6.5 MW, max.neutron flux up to 6x10 13 n.cm -2 s -1 ). By applying new techniques of target preparation, 60 Co for sterilization units of specific activity 1.11 TBq/g could be produced. Maximal activity of sup 1 sup 9 sup 2 Ir would be about 1.48 TBq what is satisfactory for the sources for gamma radiography. The increase of the flux to 10 14 n.cm -2 s -1 would enable the production of 60 Co of specific activities about 3.335 TBq/g. This is satisfactory for the sources for the radiation therapy of activities up to 111 TBq and for gamma radiography of activities about 0.37 TBq. In the case of 192 Ir the sources for the radiation therapy of activities about 0.37 TBq could be obtained. Maximal achievable activities of 192 Ir would be about 3.7 TBq. (author)

  11. Gamma radiation (Co60) effects on active substances and microbe burden of medicinal plants

    International Nuclear Information System (INIS)

    Dall'Agnol, L.

    2001-01-01

    In order to evaluate the effects of radioactivity on active vegetal substances, samples of Fennel (Foeniculum vulgare Miller., fructus), Guarana (Paulinia cupana, Kunth, semen), Gingko (gingko biloba, L., folium), and Kawa-Kawa (Piper methysticum G. Forst, rhizoma), were treated with scaling doses (0 to 25 KGy) of gamma radiation (Co 60 ). The 'blind test' methodology was used. The active substances from each sample were analysed by qualitative and quantitative methods after radiation. There were no significant differences seen between the control sample (0 KGy) and the irradiated samples. Microbe contamination was significantly reduced, about 10000 CFU/g, with the initial 5 KGy dose. It was concluded that gamma radiation can be used as an alternative procedure to reduce microbiologic contamination in medicinal plants. Before this procedure can be extended to other medicinal plants, more specific analytical methods are recommended to verify possible structural alterations in active vegetal molecules. (author)

  12. Circulating gamma delta T cells are activated and depleted during progression of high-grade gliomas: Implications for gamma delta T cell therapy of GBM

    Science.gov (United States)

    Glioblastoma multiforme (GBM) remains frustratingly impervious to any existing therapy. We have previously shown that GBM is sensitive to recognition and lysis by ex vivo activated gamma delta T cells, a minor subset of lymphocytes that innately recognize autologous stress-associated target antigens...

  13. Very high energy gamma ray astronomy from Hanle

    International Nuclear Information System (INIS)

    Chitnis, Varsha R.

    2015-01-01

    Over a past decade very high energy (VHE) gamma ray astronomy has emerged as a major astronomical discipline. In India, we have a long tradition of experiments in this field. Few years ago, multi-institutional Himalayan Gamma Ray Observatory (HiGRO) collaboration was formed to set up VHE gamma rays experiments at Hanle, a high altitude location in Himalayas. HAGAR, the first phase of this collaboration is operational since 2008. HAGAR has successfully detected VHE gamma ray emission from some of the extragalactic objects like Mrk 421, Mrk 501 as well as galactic sources including Crab nebula/pulsar. Details of HAGAR telescope system and results obtained will be discussed. HiGRO is now gearing up for the next phase, i.e. 21 m diameter MACE telescope, which is being installed at Hanle at present. Details of MACE telescope system and future plans will be discussed. (author)

  14. Discrimination of irradiated MOX fuel from UOX fuel by multivariate statistical analysis of simulated activities of gamma-emitting isotopes

    Science.gov (United States)

    Åberg Lindell, M.; Andersson, P.; Grape, S.; Hellesen, C.; Håkansson, A.; Thulin, M.

    2018-03-01

    This paper investigates how concentrations of certain fission products and their related gamma-ray emissions can be used to discriminate between uranium oxide (UOX) and mixed oxide (MOX) type fuel. Discrimination of irradiated MOX fuel from irradiated UOX fuel is important in nuclear facilities and for transport of nuclear fuel, for purposes of both criticality safety and nuclear safeguards. Although facility operators keep records on the identity and properties of each fuel, tools for nuclear safeguards inspectors that enable independent verification of the fuel are critical in the recovery of continuity of knowledge, should it be lost. A discrimination methodology for classification of UOX and MOX fuel, based on passive gamma-ray spectroscopy data and multivariate analysis methods, is presented. Nuclear fuels and their gamma-ray emissions were simulated in the Monte Carlo code Serpent, and the resulting data was used as input to train seven different multivariate classification techniques. The trained classifiers were subsequently implemented and evaluated with respect to their capabilities to correctly predict the classes of unknown fuel items. The best results concerning successful discrimination of UOX and MOX-fuel were acquired when using non-linear classification techniques, such as the k nearest neighbors method and the Gaussian kernel support vector machine. For fuel with cooling times up to 20 years, when it is considered that gamma-rays from the isotope 134Cs can still be efficiently measured, success rates of 100% were obtained. A sensitivity analysis indicated that these methods were also robust.

  15. Role of 4-1BB receptor in the control played by CD8(+ T cells on IFN-gamma production by Mycobacterium tuberculosis antigen-specific CD4(+ T Cells.

    Directory of Open Access Journals (Sweden)

    Carla Palma

    Full Text Available BACKGROUND: Antigen-specific IFN-gamma producing CD4(+ T cells are the main mediators of protection against Mycobacterium tuberculosis infection both under natural conditions and following vaccination. However these cells are responsible for lung damage and poor vaccine efficacy when not tightly controlled. Discovering new tools to control nonprotective antigen-specific IFN-gamma production without affecting protective IFN-gamma is a challenge in tuberculosis research. METHODS AND FINDINGS: Immunization with DNA encoding Ag85B, a candidate vaccine antigen of Mycobacterium tuberculosis, elicited in mice a low but protective CD4(+ T cell-mediated IFN-gamma response, while in mice primed with DNA and boosted with Ag85B protein a massive increase in IFN-gamma response was associated with loss of protection. Both protective and non-protective Ag85B-immunization generated antigen-specific CD8(+ T cells which suppressed IFN-gamma-secreting CD4(+ T cells. However, ex vivo ligation of 4-1BB, a member of TNF-receptor super-family, reduced the massive, non-protective IFN-gamma responses by CD4(+ T cells in protein-boosted mice without affecting the low protective IFN-gamma-secretion in mice immunized with DNA. This selective inhibition was due to the induction of 4-1BB exclusively on CD8(+ T cells of DNA-primed and protein-boosted mice following Ag85B protein stimulation. The 4-1BB-mediated IFN-gamma inhibition did not require soluble IL-10, TGF-beta, XCL-1 and MIP-1beta. In vivo Ag85B stimulation induced 4-1BB expression on CD8(+ T cells and in vivo 4-1BB ligation reduced the activation, IFN-gamma production and expansion of Ag85B-specific CD4(+ T cells of DNA-primed and protein-boosted mice. CONCLUSION/SIGNIFICANCE: Antigen-specific suppressor CD8(+ T cells are elicited through immunization with the mycobacterial antigen Ag85B. Ligation of 4-1BB receptor further enhanced their suppressive activity on IFN-gamma-secreting CD4(+ T cells. The selective

  16. Iron influence in self-attenuation of gamma radiation in sand samples

    Energy Technology Data Exchange (ETDEWEB)

    Aquino, Reginaldo R.; Cavalcante, Fernanda; Pecequilo, Brigitte R.S, E-mail: raquino@ipen.br, E-mail: fcavalcante@ipen.br, E-mail: brigitte@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Self-attenuation of gamma rays are usually observed in sand samples, due to the presence of iron particles of natural or anthropogenic causes, which may lead to misleading activities concentrations results. As iron atoms are often present in sand samples, the self-attenuation contribution from this mineral requires special attention when assessing sand samples radioactivity. This contributions in verified in the in the present study, using several silica (sand-like) samples doped with different concentrations of iron. The samples were arranged with pure SiO{sub 4} (98,9%) mineral from the region of Setiba, (Espirito Santo state, Brazil) and Itabirito mineral, from Itabira (Minas Gerais state, Brazil), using standard 100 mL high density polyethylene (HDPE) flat-botton cylindrical flasks, each sealed using a 52.5 mm plan screw cap and bubble spigot. Three samples were arranged in different concentrations - Fe 25% and SiO{sub 4} 75%; Fe 50% and SiO{sub 4} 50%; Fe 75% and SiO{sub 4} 25% and two other samples were assembled in the same geometry, using 100% SiO{sub 4} and 100% Fe. These samples were exposed to a large spectrum of gamma radiation (121 keV to 1408 keV) emitted by sources of {sup 60}Co, {sup 137}Cs and {sup 152}Eu. These gamma radiations were collimated and directed over the doped samples in a high resolution gamma ray spectrometer, whose spectra were analyzed with the Winner Gamma software. The matrix effect intensity is inferred by the percentage differences observed in varying the iron concentration that proved to be more intense for lower energy radiation. (author)

  17. Recent developments in white light emitting diodes

    Science.gov (United States)

    Lohe, P. P.; Nandanwar, D. V.; Belsare, P. D.; Moharil, S. V.

    2018-05-01

    In the recent years solid state lighting based on LEDs has revolutionized lighting technology. LEDs have many advantages over the conventional lighting based on fluorescent and incandescent lamps such as mercury free, high conversion efficiency of electrical energy into light, long lifetime reliability and ability to use with many types of devices. LEDs have emerged as a new potentially revolutionary technology that could save up to half of energy used for lighting applications. White LEDs would be the most important light source in the future, so much so that this aspect had been highlighted by the Nobel committee during the award of 2014 Nobel Prize for Physics. Recent advancement in the fabrication of GaN chip capable of emitting in blue and near UV region paved way for fabrication of white LED lamps. Mainly there are two approaches used for preparing white emitting solid state lamp. In the first approach blue light (λ=450 nm) emitted from the InGaN LED chip is partially absorbed by the YAG:Ce3+ phosphor coated on it and re-emitted as yellow fluorescence. A white light can be generated by the combination of blue + yellow emission bands. These lamps are already available. But they are suffering from major drawback that their Colour Rendering Index (CRI) is low. In the second approach, white LEDs are made by coating near ultraviolet emitting (360 to 410nm) LED with a mixture of high efficiency red, green and blue emitting phosphors, analogous to the fluorescent lamp. This method yields lamps with better color rendition. Addition of a yellow emitting phosphor improves CRI further. However conversion efficiency is compromised to some extent. Further the cost of near UV emitting chip is very high compared to blue emitting chips. Thus cost and light output wise, near UV chips are much inferior to blue chips. Recently some rare earth activated oxynitrides, silicates, fluorides have emerged as an important family of luminescent materials for white LED application

  18. Radiation Build-Up Of High Energy Gamma In Shielding Of High Atomic Number

    International Nuclear Information System (INIS)

    Yuliati, Helfi; Akhadi, Mukhlis

    2000-01-01

    Research to observe effect of radiation build-up factor (b) in iron (Fe) and lead (Pb) for high energy gamma shielding from exp.137 Cs (E gamma : 662 keV) and exp.60 Co (E gamma : 1332 keV) sources has been carried out. Research was conducted bt counting of radiation intensity behind shielding with its thickness vary from 1 to 5 times of half value thickness (HVT). NaI (TI) detector which connected to multi channel analyzer (MCA) was used for the counting. Calculation result show that all of b value are near to 1 (b∼1) both for Fe and Pb. Without inserting b in calculation, from the experiment it was obtained HVT value of Fe for high gamma radiation of 662 and 1332 keV were : (12,94 n 0,03) mm and (17,33 n 0,01) mm with their deviation standards were 0,2% and 0,06% respectively. Value of HVT for Pb with the same energy were : (6,31 n 0,03) mm and (11,86 n 0,03) mm with their deviation standars were : 0,48% and 0,25% respectively. HVL concept could be applied directly to estimate shielding thickness of high atomic number of high energy gamma radiation, without inserting correction of radiation build-up factor

  19. Tangential channel for nuclear gamma-resonance spectroscopy in thermal neutron capture

    International Nuclear Information System (INIS)

    Belogurov, V.N.; Bondars, H.Ya.; Lapenas, A.A.; Reznikov, R.S.; Senkov, P.E.

    1979-01-01

    Design of a tangential reactor channel which has been made to replace the radial one in the pulsed research reactor IRT-2000 is described. It allows to use the same hole in biological reactor schielding. Characteristics of neutron and gamma-background spectra at the excit of the channel are given and compared with analogous characteristics of the radial one. The gamma background in the tangential channel is lower than in the radial channel. The gamma spectra in the Gd 155 (n, γ)Gd 156 , Gd 157 (n, γ)Gd 158 , Er 167 (n, γ)Er 168 and Hf 177 (n, γ)Hf 178 reactions show that the application of X-ray detection units BDR with the tangential channel allows to carry out the gamma spectrometry of gamma quanta emitted in the thermal neutron capture by both high and low neutron capture cross section nuclei (e.g., Gdsup(157, 155) and Er 167 , Hf 177 , respectively)

  20. Comparison of laser fluorimetry, high resolution gamma-ray spectrometry and neutron activation analysis techniques for determination of uranium content in soil samples

    International Nuclear Information System (INIS)

    Ghods, A.; Asgharizadeh, F.; Salimi, B.; Abbasi, A.

    2004-01-01

    Much more concern is given nowadays for exposure of the world population to natural radiation especially to uranium since 57% of that exposure is due to radon-222, which is a member of uranium decay series. Most of the methods used for uranium determination is low concentration require either tedious separation and preconcentration or the accessibility to special instrumentation for detection of uranium at this low level. this study compares three techniques and methods for uranium analysis among different soil sample with variable uranium contents. Two of these techniques, neutron activation analysis and high resolution gamma-ray spectrometry , are non-destructive while the other, laser fluorimetry is done via chemical extraction of uranium. Analysis of standard materials is done also to control the quality and accuracy of the work. In spite of having quite variable ranges of detection limit, results obtained by high resolution gamma-ray spectrometry based on the assumption of having secular equilibrium between uranium and its daughters, which causes deviation whenever this condition was missed. For samples with reasonable uranium content, neutron activation analysis would be a rapid and reliable technique, while for low uranium content laser fluorimetry would be the most appropriate and accurate technique

  1. Measurement of the relative power density distribution of the IPEN/MB-01 reactor, using a fuel rod gamma scanning technique

    International Nuclear Information System (INIS)

    Carneiro, Alvaro Luiz Guimaraes

    1996-01-01

    This work presents a measurement methodology for determination of radial and axial relative power density distribution of the IPEN/MB-01 Reactor core by means of the fuel rod gamma scanning. The methodology is based on the proportionality between gamma activity emitted by the radioactive decay of the fission products and power density. The scanning technique consists of counting gamma radiation above 0,6 MeV along the active area of the fuel rod, getting a distribution profile. The experimental results will be used as a benchmark for qualification and to establish possible deviations for the calculational methodology currently used at IPEN. The comparison of the calculated and measured results showed good agreement. (author)

  2. SNM gamma-ray fingerprint monitor functional requirements and design specifications

    International Nuclear Information System (INIS)

    Bieber, A.M. Jr.; Kane, W.R.

    1994-07-01

    A number of DOE facilities need to perform confirmatory inventory measurements on items of special nuclear material (SNM). The DOE Office of Safeguards and Security (OSS) has tasked the Safeguards, Safety and Nonproliferation Division (SSN) of the Department of Advanced Technology at Brookhaven National Laboratory (BNL) to develop a high-resolution gamma-ray-spectroscopy-based instrument for performing confirmatory inventory measurements on such materials, a ''gamma-ray fingerprint monitor'' (GRFM). This document is a conceptual design for the SSN GRFM system. This conceptual design is based on previous experience with measurements of plutonium-bearing materials and comparison of gamma-ray spectrum features, not on actual tests of the procedures or hardware described. As a result, modifications may be necessary when actual prototype hardware and software are tested in realistic circumstances on actual materials of interest

  3. Neutron counting and gamma spectroscopy with PVT detectors

    International Nuclear Information System (INIS)

    Mitchell, Dean James; Brusseau, Charles A.

    2011-01-01

    Radiation portals normally incorporate a dedicated neutron counter and a gamma-ray detector with at least some spectroscopic capability. This paper describes the design and presents characterization data for a detection system called PVT-NG, which uses large polyvinyl toluene (PVT) detectors to monitor both types of radiation. The detector material is surrounded by polyvinyl chloride (PVC), which emits high-energy gamma rays following neutron capture reactions. Assessments based on high-energy gamma rays are well suited for the detection of neutron sources, particularly in border security applications, because few isotopes in the normal stream of commerce have significant gamma ray yields above 3 MeV. Therefore, an increased count rate for high-energy gamma rays is a strong indicator for the presence of a neutron source. The sensitivity of the PVT-NG sensor to bare 252 Cf is 1.9 counts per second per nanogram (cps/ng) and the sensitivity for 252 Cf surrounded by 2.5 cm of polyethylene is 2.3 cps/ng. The PVT-NG sensor is a proof-of-principal sensor that was not fully optimized. The neutron detector sensitivity could be improved, for instance, by using additional moderator. The PVT-NG detectors and associated electronics are designed to provide improved resolution, gain stability, and performance at high-count rates relative to PVT detectors in typical radiation portals. As well as addressing the needs for neutron detection, these characteristics are also desirable for analysis of the gamma-ray spectra. Accurate isotope identification results were obtained despite the common impression that the absence of photopeaks makes data collected by PVT detectors unsuitable for spectroscopic analysis. The PVT detectors in the PVT-NG unit are used for both gamma-ray and neutron detection, so the sensitive volume exceeds the volume of the detection elements in portals that use dedicated components to detect each type of radiation.

  4. A data acquisition and control system for high-speed gamma-ray tomography

    Science.gov (United States)

    Hjertaker, B. T.; Maad, R.; Schuster, E.; Almås, O. A.; Johansen, G. A.

    2008-09-01

    A data acquisition and control system (DACS) for high-speed gamma-ray tomography based on the USB (Universal Serial Bus) and Ethernet communication protocols has been designed and implemented. The high-speed gamma-ray tomograph comprises five 500 mCi 241Am gamma-ray sources, each at a principal energy of 59.5 keV, which corresponds to five detector modules, each consisting of 17 CdZnTe detectors. The DACS design is based on Microchip's PIC18F4550 and PIC18F4620 microcontrollers, which facilitates an USB 2.0 interface protocol and an Ethernet (IEEE 802.3) interface protocol, respectively. By implementing the USB- and Ethernet-based DACS, a sufficiently high data acquisition rate is obtained and no dedicated hardware installation is required for the data acquisition computer, assuming that it is already equipped with a standard USB and/or Ethernet port. The API (Application Programming Interface) for the DACS is founded on the National Instrument's LabVIEW® graphical development tool, which provides a simple and robust foundation for further application software developments for the tomograph. The data acquisition interval, i.e. the integration time, of the high-speed gamma-ray tomograph is user selectable and is a function of the statistical measurement accuracy required for the specific application. The bandwidth of the DACS is 85 kBytes s-1 for the USB communication protocol and 28 kBytes s-1 for the Ethernet protocol. When using the iterative least square technique reconstruction algorithm with a 1 ms integration time, the USB-based DACS provides an online image update rate of 38 Hz, i.e. 38 frames per second, whereas 31 Hz for the Ethernet-based DACS. The off-line image update rate (storage to disk) for the USB-based DACS is 278 Hz using a 1 ms integration time. Initial characterization of the high-speed gamma-ray tomograph using the DACS on polypropylene phantoms is presented in the paper.

  5. A data acquisition and control system for high-speed gamma-ray tomography

    International Nuclear Information System (INIS)

    Hjertaker, B T; Maad, R; Schuster, E; Almås, O A; Johansen, G A

    2008-01-01

    A data acquisition and control system (DACS) for high-speed gamma-ray tomography based on the USB (Universal Serial Bus) and Ethernet communication protocols has been designed and implemented. The high-speed gamma-ray tomograph comprises five 500 mCi 241 Am gamma-ray sources, each at a principal energy of 59.5 keV, which corresponds to five detector modules, each consisting of 17 CdZnTe detectors. The DACS design is based on Microchip's PIC18F4550 and PIC18F4620 microcontrollers, which facilitates an USB 2.0 interface protocol and an Ethernet (IEEE 802.3) interface protocol, respectively. By implementing the USB- and Ethernet-based DACS, a sufficiently high data acquisition rate is obtained and no dedicated hardware installation is required for the data acquisition computer, assuming that it is already equipped with a standard USB and/or Ethernet port. The API (Application Programming Interface) for the DACS is founded on the National Instrument's LabVIEW® graphical development tool, which provides a simple and robust foundation for further application software developments for the tomograph. The data acquisition interval, i.e. the integration time, of the high-speed gamma-ray tomograph is user selectable and is a function of the statistical measurement accuracy required for the specific application. The bandwidth of the DACS is 85 kBytes s −1 for the USB communication protocol and 28 kBytes s −1 for the Ethernet protocol. When using the iterative least square technique reconstruction algorithm with a 1 ms integration time, the USB-based DACS provides an online image update rate of 38 Hz, i.e. 38 frames per second, whereas 31 Hz for the Ethernet-based DACS. The off-line image update rate (storage to disk) for the USB-based DACS is 278 Hz using a 1 ms integration time. Initial characterization of the high-speed gamma-ray tomograph using the DACS on polypropylene phantoms is presented in the paper

  6. Energies and Yields of Prompt Gamma Rays from Fragments in Slow-Neutron Induced Fission of 235U

    Energy Technology Data Exchange (ETDEWEB)

    Albinsson, H [Chalmers Univ. of Technology, Goeteborg (SE)

    1971-04-15

    Measurements were made on the gamma radiation emitted from fission fragments in slow-neutron induced fission of 235U. The fragments were detected with solid state detectors of the surface barrier type and the gamma radiation with a Nal(Tl) scintillator. Mass selection was used so that the gamma radiation could be measured as a function of fragment mass. Time discrimination between the fission gammas and the prompt neutrons released in the fission process was employed to reduce the background. The gamma radiation emitted during different time intervals after the fission event was studied with the help of a collimator, the position of which was changed along the path of the fission fragments. In this way it was possible to select various collimator settings and let gamma radiation of different half-lives be enhanced. Gamma-ray energy spectra from these time components were then recorded as function of mass. The spectrum shape differed greatly depending on the half-life of the radiation and the fragment from which it was emitted. The results of the present measurements were discussed in the light of existing fission models, and comparisons were made with prompt gamma-ray and neutron data from other fission experiments

  7. Energies and Yields of Prompt Gamma Rays from Fragments in Slow-Neutron Induced Fission of 235U

    International Nuclear Information System (INIS)

    Albinsson, H.

    1971-04-01

    Measurements were made on the gamma radiation emitted from fission fragments in slow-neutron induced fission of 235 U. The fragments were detected with solid state detectors of the surface barrier type and the gamma radiation with a Nal(Tl) scintillator. Mass selection was used so that the gamma radiation could be measured as a function of fragment mass. Time discrimination between the fission gammas and the prompt neutrons released in the fission process was employed to reduce the background. The gamma radiation emitted during different time intervals after the fission event was studied with the help of a collimator, the position of which was changed along the path of the fission fragments. In this way it was possible to select various collimator settings and let gamma radiation of different half-lives be enhanced. Gamma-ray energy spectra from these time components were then recorded as function of mass. The spectrum shape differed greatly depending on the half-life of the radiation and the fragment from which it was emitted. The results of the present measurements were discussed in the light of existing fission models, and comparisons were made with prompt gamma-ray and neutron data from other fission experiments

  8. Thermally Activated Delayed Fluorescence Emitters for Deep Blue Organic Light Emitting Diodes: A Review of Recent Advances

    Directory of Open Access Journals (Sweden)

    Thanh-Tuân Bui

    2018-03-01

    Full Text Available Organic light-emitting diodes offer attractive perspectives for the next generation display and lighting technologies. The potential is huge and the list of potential applications is almost endless. So far, blue emitters still suffer from noticeably inferior electroluminescence performances in terms of efficiency, lifespan, color quality, and charge injection/transport when compared to that of the other colors. Emitting materials matching the NTSC standard blue of coordinates (0.14, 0.08 are extremely rare and still constitutes the focus of numerous academic and industrial researches. In this context, we review herein the recent developments on highly emissive deep-blue thermally activated delayed fluorescence emitters that constitute the third-generation electroluminescent materials.

  9. Epidermis-type lipoxygenase 3 regulates adipocyte differentiation and peroxisome proliferator-activated receptor gamma activity

    DEFF Research Database (Denmark)

    Hallenborg, Philip; Jørgensen, Claus; Petersen, Rasmus K

    2010-01-01

    preadipocytes. Here, we show that forced expression of eLOX3 or addition of eLOX3 products stimulated adipogenesis under conditions that normally require an exogenous PPAR gamma ligand for differentiation. Hepoxilins, a group of oxidized arachidonic acid derivatives produced by eLOX3, bound to and activated...... PPAR gamma. Production of hepoxilins was increased transiently during the initial stages of adipogenesis. Furthermore, small interfering RNA-mediated or retroviral short hairpin RNA-mediated knockdown of eLOX3 expression abolished differentiation of 3T3-L1 preadipocytes. Finally, we demonstrate...... differentiation has remained enigmatic. Previously, we showed that lipoxygenase (LOX) activity is involved in activation of PPAR gamma during the early stages of adipocyte differentiation. Of the seven known murine LOXs, only the unconventional LOX epidermis-type lipoxygenase 3 (eLOX3) is expressed in 3T3-L1...

  10. Clinical outcomes of gamma knife radiosurgery in the salvage treatment of patients with recurrent high-grade glioma.

    Science.gov (United States)

    Elaimy, Ameer L; Mackay, Alexander R; Lamoreaux, Wayne T; Demakas, John J; Fairbanks, Robert K; Cooke, Barton S; Lamm, Andrew F; Lee, Christopher M

    2013-12-01

    Previously published randomized evidence did not report a survival advantage for patients diagnosed with grade IV glioma who were treated with stereotactic radiosurgery followed by external beam radiation therapy and chemotherapy when compared to patients treated with external beam radiation therapy and chemotherapy alone. In recent years, gamma knife radiosurgery has become increasingly popular as a salvage treatment modality for patients diagnosed with recurrent high-grade glioma. The purpose of this article is to review the efficacy of gamma knife radiosurgery for patients who suffer from this malignancy. Retrospective, prospective, and randomized clinical studies published between the years 2000 and 2012 analyzing gamma knife radiosurgery for patients with high-grade glioma were reviewed. After assessing patient age, Karnofsky performance status, tumor histology, and extent of resection, gamma knife radiosurgery is a viable, minimally invasive treatment option for patients diagnosed with recurrent high-grade glioma. The available prospective and retrospective evidence suggests that gamma knife radiosurgery provides patients with a high local tumor control rate and a median survival after tumor recurrence ranging from 13 to 26 months. Gamma knife radiosurgery followed by chemotherapy for recurrent high-grade glioma may provide select patients with increased levels of survival. However, further investigation into this matter is needed due to the limited number of published reports. Additional clinical research is also needed to analyze the efficacy and radiation-related toxicities of fractionated gamma knife radiosurgery due to its potential to limit treatment-associated morbidity. Gamma knife radiosurgery is a safe and effective treatment option for select patients diagnosed with recurrent high-grade glioma. Although treatment outcomes have improved, further evidence in the form of phase III randomized trials is needed to assess the durability of treating

  11. Accelerator Production and Separations for High Specific Activity Rhenium-186

    Energy Technology Data Exchange (ETDEWEB)

    Jurisson, Silvia S. [Univ. of Missouri, Columbia, MO (United States); Wilbur, D. Scott [Univ. of Washington, Seattle, WA (United States)

    2016-04-01

    Tungsten and osmium targets were evaluated for the production of high specific activity rhenium-186. Rhenium-186 has potential applications in radiotherapy for the treatment of a variety of diseases, including targeting with monoclonal antibodies and peptides. Methods were evaluated using tungsten metal, tungsten dioxide, tungsten disulfide and osmium disulfide. Separation of the rhenium-186 produced and recycling of the enriched tungsten-186 and osmium-189 enriched targets were developed.

  12. Developments in gamma-ray spectrometry: systems, software, and methods-II. 3. Low-Energy Gamma-Ray Spectrometry Using a Compton-Suppressed Telescope Detector

    International Nuclear Information System (INIS)

    Sigg, R.A.; DiPrete, D.P.

    2001-01-01

    The Savannah River Technology Center (SRTC) utilizes gamma-ray spectrometry in studying numerous areas of applied interest to the Savannah River Site (SRS). For example, analyses of long-lived gamma-ray-emitting fission products and actinides are required to meet waste characterization, process holdup, environmental restoration, and decontamination and decommissioning efforts. A significant portion of the overall effort centers on measurements of gamma rays having energies below several hundred kilo-electron-volts. To assist these efforts, the SRTC recently acquired a spectrometer system that provides lower natural and Compton scattered background levels while achieving relatively high counting efficiencies for low-energy gamma rays. The combination of high efficiency and low background provides factor-of- 2-to-4 improvements in minimum detectable activities and allows meeting programmatic objectives with shorter measurement times. Numerous Compton-suppression spectrometers have been reported since the concept was first advanced. The spectrometer consists of two high-purity germanium detectors in a telescope configuration surrounded by a background /Compton-suppression sodium iodide detector. The front germanium detector is a 20-mm-thick x 60-mm-diam broad energy spectrometer, and the rear detector is a 40% efficient 61- mm-diam x 60-cm-thick closed-end coaxial spectrometer. The cryostat housing the germanium detectors (a) includes a carbon composite window for transmitting low-energy gamma rays, (b) is in a J-type configuration to mask the germanium detectors from natural activities in the cryo-pumping media, and (c) is fabricated from materials selected for low background. The telescope detector is in the 8.6-cm-inside-diameter annulus of a 22.9- x 22.9-cm sodium iodide detector encased in a 10-cm-thick lead shield. The counting system is located in a basement counting room having ∼60-cm-thick concrete walls. Initial tests show that the low-energy segment of

  13. Gamma factors of an ambulatory source; Factores gamma de una fuente ambulatoria

    Energy Technology Data Exchange (ETDEWEB)

    Arcos P, A; Vega C, H R; Manzanares A, E; Salas L, M A; Hernandez D, V M [Unidades Academicas de Estudios Nucleares e Ingenieria Electrica, Universidad Autonoma de Zacatecas, C. Cipres 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Barquero, R [Hospital Universitario del Rio Hortega, E-47010 Valladolid (Spain)

    2007-07-01

    Some of the procedures for diagnostic or treatment used in the medicine use radioactive materials as the I{sup 131}. By means of Monte Carlo methods were calculated the doses in the internal organs of a woman, with three months of pregnancy, due to the radioiodine captured by her thyroid, as well as to 1 meter of the gland. A three-dimensional mathematical model of the body of a woman was used and by means of Monte Carlo, the radioiodine photons were transported isotropically from the thyroid toward the whole body and was calculated the absorbed dose by their internal organs, also the Kerma in air (K) was determined and the environmental equivalent dose (H{sup *}(10)) at 1 m of the gland. Two activity factors at dose were determined, Gamma Factors that it allows to estimate the dose that the patient produces to people to its around. Of the gamma radiation that emits the I{sup 131} in the thyroid was found that the thymus receives the biggest dose while the uterus is the organ that smaller dose receives. The determined gamma factors were: {gamma}{sub KAire} = 56 {mu}Gy-m{sup 2}-h{sup -1}-GBq{sup -1}, and {gamma}{sub H}{sup *}{sub (10)} = 73 {mu}Sv-m{sup 2}-h{sup -1}-GBq{sup -1}. The distribution of the absorbed dose by the internal organs is attributed to the relative distance among the thyroid and the other organs, to the inter-organs shielding, its size and to its elementary composition. The {gamma}{sub KAire} and {gamma}{sub H}{sup *}{sub (10)} factors allow to estimate the exposure that the patient produces on the personnel to its around. With this, the nuclear medicus, the medical physicist or the one responsible of the radiological safety in the hospital can give more precise indications on the behavior of people around the patient. (Author)

  14. Preparation of tritiated thymidine of high specific activity

    International Nuclear Information System (INIS)

    Ivan'kova, E.K.; Sidorov, G.V.; Myasoedov, N.F.

    1981-01-01

    Optimum conditions for the reaction are determined; and conditions for reaction component separation on resins of Dowex-1x8 and APA-8p (HCOO - , elution with ammonium formate) are optimized. It is established that the transition from thymine preparations with the specific activity of 0.15 and 1.5 TBq/mmol to the preparation with the specific activity of 3.25 TBq/mmol brings about the reduction in the desoxyribosylation reaction rate and the decrease in the thymidine yield from 85-90 to 65% [ru

  15. Assessment of gamma, beta and alpha-particle-emitting nuclides in marine samples

    International Nuclear Information System (INIS)

    Holm, E.

    1997-01-01

    Depending on the physical properties of radionuclides different systems must be used for their measurement. Most convenient is if gamma spectrometry can be used by germanium, Silicon or Scintillation detectors (eg. NaI). If, however, the main emission consists of beta or alpha particles or low-energy photons as is the case for radionuclides decaying by electron capture, radiochemical separation and specific source preparations must be undertaken. In such cases also the radiochemical yield must be determined. The radiochemical part mainly follows the lines presented by prof. T. Jaakkola, Department of Radiochemistry, Helsinki, Finland, at a course in radioecology in Lurid, 1991. For very long-lived radionuclides other methods such as mass spectrometry are superior although often associated with sophisticated expensive instrumentation. (author)

  16. Physicochemical properties of cross-linked poly-gamma-glutamic acid and its flocculating activity against kaolin suspension

    International Nuclear Information System (INIS)

    Taniguchi, M.; Kato, K.; Shimauchi, A.; Ping, X.; Fujita, K.; Tanaka, T.; Tarui, Y.; Hirasawa, E.

    2005-01-01

    Cross-linked poly-Gamma-glutamic acid (C-L Gamma-PGA) was prepared with Gamma-PGA irradiated with Gamma-PGA at various kGy values. The physicochemical properties including viscosity and water absorption capacity were compared between C-L Gamma-PGA and several typical flocculating agents. The viscosity of C-L Gamma-PGA increased with the dose of Gamma-lrradiatio, although the water absorption capacity of C-L Gamma-PGA did not, which showed a maximum of 1005.6 ml/g at 20 kGy. Flocculating activity against kaolin suspension was not observed for any of the test compounds when used singly. However, the activity of C-L Gamma-PGA markedly increased following the addition of polyaluminum chloride. The activity increased with temperature up to 80deg C and remained at 80 deg C of heat pretreatment for 1 h, but did not at more than 50 deg C of beat pretreatment for 24 h. The activity was also observed within a pH range of 4.5-10.0. Roth the water absorption capacity and flocculating activity of C-L Gamma-PGA decreased in parallel with increasing NaCl concentration, suggesting that the hocculating activity of C-L Gamma-PGA was associated with its water absorption capacity, rather than viscosity. An investigation of the effects of various cations on the flocculating activity of C-L Gamma-PGA showed that only trivalent catlons had a synergistic effect. The mechanism of C-L Gamma-PGA flocculating activity is discussed based on the results of preliminary experiments

  17. Coaxial Mono-Energetic Gamma Generator for Active Interrogation

    International Nuclear Information System (INIS)

    Ludewigt, Bernhard A.; Antolak, A.J.; Henestroza, E.; Leitner, M.; Leung, K.-N.; Waldron, W.; Wilde, S.; Kwan, J.W.

    2008-01-01

    Compact mono-energetic photon sources are sought for active interrogation systems to detect shielded special nuclear materials in, for example, cargo containers, trucks and other vehicles. A prototype gamma interrogation source has been designed and built that utilizes the 11B(p,gamma)12C reaction to produce 12 MeV gamma-rays which are near the peak of the photofission cross section. In particular, the 11B(p,gamma)12C resonance at 163 kV allows the production of gammas at low proton acceleration voltages, thus keeping the design of a gamma generator comparatively small and simple. A coaxial design has been adopted with a toroidal-shaped plasma chamber surrounding a cylindrical gamma production target. The plasma discharge is driven by a 2 MHz rf-power supply (capable up to 50 kW) using a circular rf-antenna. Permanent magnets embedded in the walls of the plasma chamber generate a multi-cusp field that confines the plasma and allows higher plasma densities and lower gas pressures. About 100 proton beamlets are extracted through a slotted plasma electrode towards the target at the center of the device that is at a negative 180 kV. The target consists of LaB6 tiles that are brazed to a water-cooled cylindrical structure. The generator is designed to operate at 500 Hz with 20 mu s long pulses, and a 1percent duty factor by pulsing the ion source rf-power. A first-generation coaxial gamma source has been built for low duty factor experiments and testing.

  18. Janus probe, a detection system for high energy reactor gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Gold, R.; Kaiser, B.J.

    1980-03-01

    In reactor environments, gamma-ray spectra are continuous and the absolute magnitude as well as the general shape of the gamma continuum are of paramount importance. Consequently, conventional methods of gamma-ray detection are not suitable for in-core gamma-ray spectrometry. To meet these specific needs, a method of continuous gamma-ray spectrometry, namely Compton Recoil Gamma-Ray Spectrometry, was developed for in-situ observations of reactor environments. A new gamma-ray detection system has been developed which extends the applicability of Compton Recoil Gamma-Ray Spectrometry up to roughly 7 MeV. This detection system is comprised of two separate Si(Li) detectors placed face-to-face. Hence this new detection system is called the Janus probe. Also shown is the block diagram of pulse processing instrumentation for the Janus probe. This new gamma probe not only extends the upper energy limit of in-core gamma-ray spectrometry, but in addition possesses other fundamental advantages

  19. Propagation speed of {gamma}-radiation in air

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcante, Jose T.P.D.; Silva, Paulo R.J.; Saitovitch, Henrique [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil); Macedo Junior, Marcelo A.V. [Centro Federal de Educacao Tecnologica de Quimica de Nilopolis (CEFET), RJ (Brazil)

    2008-07-01

    To perform such measurements the availability of a gamma radiation source in which two {gamma}-rays are emitted simultaneously in opposite directions -as already used(5,6) as well as applied in the present case- turns out to be essential to the feasibility of the experiment, as far as no reflection techniques could be used. Such suitable source was the positron emitter {sup 22}Na placed in a metal container in which the positrons are stopped and annihilated when reacting with the medium electrons, in such way originating -as it is very well established from momentum/energy conservation laws(7)- two {gamma}-rays, energy 511 KeV each, both emitted simultaneously in opposite directions. In all these previous experiments were used photomultiplier detectors coupled to NaI(Tl) crystal scintillators, which have a good energy resolution but a deficient time resolution for such purposes. Presently, as an innovatively improvement, were used BaF{sub 2} and CsF crystal scintillators which display a much better time resolution. (author)

  20. Measurement of Neutron Energy Spectrum Emitted by Cf-252 Source Using Time-of-Flight Method

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheol Ho; Son, Jaebum; Kim, Tae Hoon; Lee, Sangmin; Kim, Yong-Kyun [Hanyang University, Seoul (Korea, Republic of)

    2016-10-15

    The techniques proposed to detect the neutrons usually require the detection of a secondary recoiling nucleus in a scintillator (or other type of detector) to indicate the rare collision of a neutron with a nucleus. This is the same basic technique, in this case detection of a recoil proton that was used by Chadwick in the 1930 s to discover and identify the neutron and determine its mass. It is primary technique still used today for detection of fast neutron, which typically involves the use of a hydrogen based organic plastic or liquid scintillator coupled to a photo-multiplier tube. The light output from such scintillators is a function of the cross section and nuclear kinematics of the n + nucleus collision. With the exception of deuterated scintillators, the scintillator signal does not necessarily produce a distinct peak in the scintillator spectrum directly related to the incident neutron energy. Instead neutron time-of-flight (TOF) often must be utilized to determine the neutron energy, which requires generation of a prompt start signal from the nuclear source emitting the neutrons. This method takes advantage of the high number of prompt gamma rays. The Time-of-Flight method was used to measure neutron energy spectrum emitted by the Cf-252 neutron source. Plastic scintillator that has a superior discrimination ability of neutron and gamma-ray was used as a stop signal detector and liquid scintillator was used as a stat signal detector. In experiment, neutron and gamma-ray spectrum was firstly measured and discriminated using the TOF method. Secondly, neutron energy spectrum was obtained through spectrum analysis. Equation of neutron energy spectrum that was emitted by Cf-252 source using the Gaussian fitting was obtained.

  1. Late effects of low-energy gamma-emitting stents in a rabbit iliac artery model

    International Nuclear Information System (INIS)

    Strauss, Bradley H.; Li, Chris; Whittingham, Heather A.; Tio, Fermin O.; Kutryk, Michael J.B.; Janicki, Christian; Sparkes, John D.; Turnlund, Todd; Sweet, William L.

    2002-01-01

    Purpose: To determine the long-term dose response of novel low-dose γ-emitting stents in a rabbit iliac artery model. Methods and Materials: Control stents (n=24) and 103 Pd stents 1.0 to 4.0 mCi (n=36) were implanted in the iliac arteries of 30 New Zealand rabbits. Stents were evaluated by intravascular ultrasound (immediately post procedure and before killing) and by histomorphometry. Results: At 26 weeks, 28 rabbits were killed, with no evidence of stent thrombosis. In the body of the stent there was a dose-response relationship with 50% inhibition of intimal hyperplasia at the highest activity compared to control stents (p=0.07) and a significant increase in intimal hyperplasia at the lowest activity (p 103 Pd stents is feasible with reduction of in-stent hyperplasia in a dose-related manner. However, significant narrowing at the stent edges, increased in-stent hyperplasia at lower activities, and incomplete vascular healing with persistence of immature neointima at higher activities are significant limitations

  2. Study of the high energy gamma-ray emission from the crab pulsar with the MAGIC telescope and Fermi-LAT

    International Nuclear Information System (INIS)

    Saito, Takayuki

    2010-01-01

    My thesis deals with a fundamental question of high energy gamma-ray astronomy. Namely, I studied the cut-off shape of the Crab pulsar spectrum to distinguish between the leading scenarios for the pulsar models. Pulsars are celestial objects, which emit periodic pulsed electromagnetic radiation (pulsation) from radio to high energy gamma-rays. Two major scenarios evolved in past 40 years to explain the pulsation mechanism: the inner magnetosphere scenario and the outer magnetosphere scenario. Both scenarios predict a high energy cut-off in the gamma-ray energy spectrum, but with different cut-off sharpness. An exponential cut-off is expected for the outer magnetosphere scenario while a super-exponential cut-off is predicted for the inner magnetosphere scenario. Therefore, one of the best ways to confirm or refute these scenarios is to measure the energy spectrum of a pulsar at around the cut-off energy, i.e., at energies between a few GeV and a few tens of GeV. All past attempts to measure pulsar spectra with ground-based instruments have failed while satellite-borne detectors had a too small area to study detailed spectra in the GeV domain. In this thesis, the gamma-ray emission at around the cut-off energy from the Crab pulsar is studied with the MAGIC telescope. The public data of the satellite-borne gamma-ray detector, Fermi-LAT, are also analyzed in order to discuss the MAGIC observation results in comparison with the adjacent energy band. In late 2007, a new trigger system (SUM trigger system) allowed to reduce the threshold energy of the MAGIC telescope from 50 GeV to 25 GeV and the Crab pulsar was successfully detected during observations from October 2007 and January 2009. My analysis reveals that the energy spectrum is consistent with a simple power law between 25 GeV to 100 GeV. The extension of the energy spectrum up to 100 GeV rules out the inner magnetosphere scenario. Fermi-LAT started operation in August 2008. The Fermi-LAT data reveal that a power

  3. Study of the high energy gamma-ray emission from the crab pulsar with the MAGIC telescope and Fermi-LAT

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Takayuki

    2010-12-06

    My thesis deals with a fundamental question of high energy gamma-ray astronomy. Namely, I studied the cut-off shape of the Crab pulsar spectrum to distinguish between the leading scenarios for the pulsar models. Pulsars are celestial objects, which emit periodic pulsed electromagnetic radiation (pulsation) from radio to high energy gamma-rays. Two major scenarios evolved in past 40 years to explain the pulsation mechanism: the inner magnetosphere scenario and the outer magnetosphere scenario. Both scenarios predict a high energy cut-off in the gamma-ray energy spectrum, but with different cut-off sharpness. An exponential cut-off is expected for the outer magnetosphere scenario while a super-exponential cut-off is predicted for the inner magnetosphere scenario. Therefore, one of the best ways to confirm or refute these scenarios is to measure the energy spectrum of a pulsar at around the cut-off energy, i.e., at energies between a few GeV and a few tens of GeV. All past attempts to measure pulsar spectra with ground-based instruments have failed while satellite-borne detectors had a too small area to study detailed spectra in the GeV domain. In this thesis, the gamma-ray emission at around the cut-off energy from the Crab pulsar is studied with the MAGIC telescope. The public data of the satellite-borne gamma-ray detector, Fermi-LAT, are also analyzed in order to discuss the MAGIC observation results in comparison with the adjacent energy band. In late 2007, a new trigger system (SUM trigger system) allowed to reduce the threshold energy of the MAGIC telescope from 50 GeV to 25 GeV and the Crab pulsar was successfully detected during observations from October 2007 and January 2009. My analysis reveals that the energy spectrum is consistent with a simple power law between 25 GeV to 100 GeV. The extension of the energy spectrum up to 100 GeV rules out the inner magnetosphere scenario. Fermi-LAT started operation in August 2008. The Fermi-LAT data reveal that a power

  4. Study, simulation and modelling of a gamma photon detector placed on an integral-type eccentric orbit; Etude, simulation et modelisation d'un detecteur de photons gamma place sur une orbite excentrique de type integral

    Energy Technology Data Exchange (ETDEWEB)

    Diallo, N

    1999-07-01

    Gamma-ray lines are the signature of nuclear reactions and other high-energy processes that take place in the Universe. Their measurement and study provide invaluable information on many important problems in high energy astrophysics, including particle acceleration, physics of compact objects and nucleosynthesis. However the observation of astronomical gamma-ray sources has to be performed above the atmosphere because the Earth's atmosphere is opaque to gamma-rays. Unfortunately at these altitudes, spatial high energy electromagnetic radiation (X and gamma rays) detectors are exposed to intense parasite fluxes of radiation and particles induced by primary galactic cosmic rays. These fluxes as well radiation and secondary particles they generate, constitute a considerable source of background which limits their performances. Our study has been done in the framework of the INTEGRAL mission, a gamma-ray astronomy mission of the European Space Agency. INTEGRAL is devoted to the observation of celestial gamma-ray sources. It consists of two main instruments: an imager IBIS and a high resolution germanium spectrometer SPI ({delta}E/E = 1.6 10{sup -3} at 1.3 MeV). We studied the hadronic component of the SPI background. This component is due to the radioactive decay of unstable nuclides produced by the interactions of cosmic-ray protons with the materials of SPI. It consists of a continuum with gamma ray lines superimposed. To study nuclear processes, Monte Carlo simulations have been performed with the nuclear code TIERCE developed at CEA/DAM. We used the GEANT Monte Carlo code developed at CERN to simulate the germanium detectors response. Background reduction techniques as PSD (Pulse Shape Discrimination) and energetic signatures have been applied in well chosen energy ranges to reduce the background. and improve the SPI sensitivity. With the estimated SPI narrow-line sensitivity level, SPI would be able to detect many gamma ray limes emitted in the active

  5. Reduction of Compton background from hydrogen in prompt gamma-ray analysis by multiple photon detection

    International Nuclear Information System (INIS)

    Toh, Y.; Oshima, M.; Kimura, A.; Koizumi, M.; Furutaka, K.; Hatsukawa, Y.

    2008-01-01

    Low-energy photons produced by the Compton scattering from hydrogen increase the background in the lower-energy region of the gamma-ray spectrum. This results in an increase in the detection limit for trace elements. In multiple photon detection prompt gamma-ray analysis (MPGA), only those elements that simultaneously emit two or more prompt gamma-rays, which have cascade relation and are emitted within a short interval, can be measured. Therefore, the influence of hydrogen can be reduced. In this study, standard polymer and food samples are measured. The hydrogen background is reduced in MPGA. (author)

  6. Extraction of surface plasmons in organic light-emitting diodes via high-index coupling.

    Science.gov (United States)

    Scholz, Bert J; Frischeisen, Jörg; Jaeger, Arndt; Setz, Daniel S; Reusch, Thilo C G; Brütting, Wolfgang

    2012-03-12

    The efficiency of organic light-emitting diodes (OLEDs) is still limited by poor light outcoupling. In particular, the excitation of surface plasmon polaritons (SPPs) at metal-organic interfaces represents a major loss channel. By combining optical simulations and experiments on simplified luminescent thin-film structures we elaborate the conditions for the extraction of SPPs via coupling to high-index media. As a proof-of-concept, we demonstrate the possibility to extract light from wave-guided modes and surface plasmons in a top-emitting white OLED by a high-index prism.

  7. GQ-16, a Novel Peroxisome Proliferator-activated Receptor gamma (PPAR gamma) Ligand, Promotes Insulin Sensitization without Weight Gain

    NARCIS (Netherlands)

    Amato, Angelica A.; Rajagopalan, Senapathy; Lin, Jean Z.; Carvalho, Bruno M.; Figueira, Ana C. M.; Lu, Jenny; Ayers, Stephen D.; Mottin, Melina; Silveira, Rodrigo L.; Telles de Souza, Paulo; Mourao, Rosa H. V.; Saad, Mario J. A.; Togashi, Marie; Simeoni, Luiz A.; Abdalla, Dulcineia S. P.; Skaf, Munir S.; Polikparpov, Igor; Lima, Maria C. A.; Galdino, Suely L.; Brennan, Richard G.; Baxter, John D.; Pitta, Ivan R.; Webb, Paul; Phillips, Kevin J.; Neves, Francisco A. R.

    2012-01-01

    The recent discovery that peroxisome proliferator-activated receptor gamma (PPAR gamma) targeted anti-diabetic drugs function by inhibiting Cdk5-mediated phosphorylation of the receptor has provided a new viewpoint to evaluate and perhaps develop improved insulin-sensitizing agents. Herein we report

  8. Gamma radiation effect on biological activity and enzymatic properties of snake venoms

    International Nuclear Information System (INIS)

    Herrera, E.; Yarleque, A.; Campos, S.; Zavaleta, A.

    1986-01-01

    The effect of gamma radiation, from Co-60, on the biological activity and on some enzymatic activities, present in the venoms of Lachesis muta and Bothrops atrox, using samples of dried venom that had been irradiated at a dose of 0.1, 0.5 and 1.0 Mrad have been studied. Variations in the degree of hemorrhage and local necrosis were observed in albino mice injected subcutaneously with venoms of both types. The reduction of the biological activity was greater for the local hemorrhagic effect and was dependent on the doses of irradiation. The specific activity of various enzymes, present in both venoms, is affected by the gamma radiation, at a dose of 0.1 Mrad the order of increasing inactivation being: exonuclease (4%), phospholipase (24%), caseinolytic enzyme (20%), tamesterase (33%), a thrombine-like enzyme (40%), fibrinolytic enzyme (41%), 5'-nucleotidase (50%) and endonuclease (55%). The enzymatic inactivation was augmented by 0.5 and 1.0 Mrad, without maintaining an arithmetic relation. The enzyme of major resistance to the radiation was exonuclease, whereas 5'-nucleotidase and endonuclease were the most sensitive. No significant changes were observed in the spectrum of UV absorbtion (range 260 to 290 nm) nor in the contents of L-tyrosine in the irradiated venoms

  9. Pair creation by very high-energy photons in gamma-ray bursts a unified picture for the energetics of GRBs

    CERN Document Server

    Totani, T

    1999-01-01

    The extreme energetics of the gamma-ray burst (GRB) 990123 have revealed that some GRBs emit quite a large amount of energy, and the total energy release from GRBs seems to change from burst to burst by a factor of 10/sup 2/-10/sup $9 3/ as E/sub gamma , iso/~10/sup 52-55/ erg, where E/sub gamma , iso/ is the observed GRB energy when the radiation is isotropic. If all GRBs are triggered by similar events, such a wide dispersion in energy release seems odd. The $9 author proposes a unified picture for the energetics of GRBs, in which all GRB events release roughly the same amount of energy E/sub iso/~10 /sup 55-56/ erg relativistic motion, with the baryon load problem almost resolved. A mild $9 dispersion in the initial Lorentz factor ( Gamma ) results in a difference of E/sub gamma , iso/ by up to a factor of m/sub p//m/sub e/~10/sup 3/. Protons work as `a hidden energy reservoir' of the total GRB energy, and E/sub gamma , $9 iso/ depends on the energy transfer efficiency from protons into electrons (or posit...

  10. DISCERNING THE GAMMA-RAY-EMITTING REGION IN THE FLAT SPECTRUM RADIO QUASARS

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Y. G. [Department of Physics, Yunnan Normal University, Kunming, 650092 (China); Yang, C. Y.; Wang, J. C. [Yunnan Observatories, Chinese Academy of Sciences, Kunming 650011 (China); Zhang, L., E-mail: ynzyg@ynu.edu.cn, E-mail: chyy@ynao.ac.cn [Department of Astronomy, Yunnan University, Kunming, 650091 (China)

    2017-01-01

    A model-dependent method is proposed to determine the location of the γ -ray-emitting region for a given flat spectrum radio quasar (FSRQ). In the model, the extra-relativistic electrons are injected at the base of the jet and non-thermal photons are produced by both synchrotron radiation and inverse-Compton (IC) scattering in the energy dissipation region. The target photons dominating IC scattering originate from both synchrotron photons and external ambient photon fields, and the energy density of external radiation field is a function of the distance between the position of the dissipation region and a central supermassive black hole, and their spectra are seen in the comoving frame. Moreover, the energy dissipation region could be determined by the model parameter through reproducing the γ -ray spectra. Such a model is applied to reproduce the quasi-simultaneous multi-wavelength observed data for 36 FSRQs. In order to define the width of the broad-line region (BLR) shell and dusty molecular torus (MT) shell, a simple numerical constraint is used to determine the outer boundary of the BLR and dusty MT. Our results show that (1) the γ -ray-emitting regions are located at the range from 0.1 to 10 pc; (2) the γ -ray-emitting regions are located outside the BLRs and within the dusty molecular tori; and (3) the γ -ray-emitting regions are located closer to the dusty MT ranges than the BLRs. Therefore, it may be concluded that direct evidence for the far site scenario could be obtained on the basis of the model results.

  11. COSANI-2, Gamma Doses from SABINE Calculation, Activity from ANISN Flux Calculation

    International Nuclear Information System (INIS)

    Dupont, C.

    1975-01-01

    1 - Nature of physical problem solved: Retrieval of SABINE and/or ANISN results. Calculates in case of SABINE results the individual contributions of capture gamma rays in each region to the total gamma dose and to the total gamma heating may calculate in case of ANISN new activity rates starting from ANISN flux saved on tape and activity cross sections taken on an ANISN binary library tape. The program can draw on a BENSON plotter any of the following quantities: - group flux; - activity rates; - dose rates; - neutron spectra for SABINE; - neutron or gamma direct or adjoint spectra for ANISN; - gamma heating and dose rate for SABINE including individual contributions from each region. Several ANISN and/or SABINE cases can be drawn on the same graph for comparison purposes. 2 - Restrictions on the complexity of the problem: Maximum number of: - tapes containing ANISN and/or SABINE results: 5; - curves per graph: 3; - regions: 40; - points per curve: 500; - energy groups: 200

  12. Study on the physiological activities of gamma-irradiated seafood cooking drips

    International Nuclear Information System (INIS)

    Jo, Eu Ri; Kim, Yeon Joo; Choi, Jong Il; Sung, Nak Yun; Jung, Pil Moon; Kim, Jae Hun; Song, Beom Seok; Yoon, Yo Han; Lee, Ju Woon; Lee, Ju Yeoun

    2010-01-01

    Cooking drips which were obtained as by-product after seafood processing in the food industries, still contain lost of proteins, carbohydrates, and other functional materials. This study was conducted to investigate the effect of gamma irradiation on the biological activities of seafood cooking drips. When the cooking drips of Hizikia fusiformis, Enteroctopus dofleini and Thunnus thynnus were irradiated, the antioxidant activities, whitening effect, and angiotensin I converting enzyme inhibition activity of the ethanol extract from seafood cooking drips were all increased by gamma irradiation. This was because of the increased extraction efficiency of available compounds by irradiation. These results suggested that the seafood cooking drips, wasted as by-products, can be used as functional compounds with gamma irradiation treatment

  13. Study on the physiological activities of gamma-irradiated seafood cooking drips

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Eu Ri; Kim, Yeon Joo; Choi, Jong Il; Sung, Nak Yun; Jung, Pil Moon; Kim, Jae Hun; Song, Beom Seok; Yoon, Yo Han; Lee, Ju Woon [Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Lee, Ju Yeoun [Chonbuk National University, Jeonju (Korea, Republic of)

    2010-03-15

    Cooking drips which were obtained as by-product after seafood processing in the food industries, still contain lost of proteins, carbohydrates, and other functional materials. This study was conducted to investigate the effect of gamma irradiation on the biological activities of seafood cooking drips. When the cooking drips of Hizikia fusiformis, Enteroctopus dofleini and Thunnus thynnus were irradiated, the antioxidant activities, whitening effect, and angiotensin I converting enzyme inhibition activity of the ethanol extract from seafood cooking drips were all increased by gamma irradiation. This was because of the increased extraction efficiency of available compounds by irradiation. These results suggested that the seafood cooking drips, wasted as by-products, can be used as functional compounds with gamma irradiation treatment.

  14. Gamma dosimetry of high doses

    International Nuclear Information System (INIS)

    Martinez C, T.; Galvan G, A.; Canizal, G.

    1991-01-01

    The gamma dosimetry of high doses is problematic in almost all the classic dosemeters either based on the thermoluminescence, electric, chemical properties, etc., because they are saturated to very high dose and they are no longer useful. This work carries out an investigation in the interval of high doses. The solid system of heptahydrate ferrous sulfate, can be used as solid dosemeter of routine for high doses of radiation. The proposed method is simple, cheap and it doesn't require sophisticated spectrophotometers or spectrometers but expensive and not common in some laboratories

  15. Application of Monte Carlo simulation to the standardization of positron emitting radionuclides

    International Nuclear Information System (INIS)

    Tongu, Margareth Lika Onishi

    2009-01-01

    Since 1967, the Nuclear Metrology Laboratory (LNM) at the Nuclear and Energy Research (IPEN) in Sao Paulo, Brazil, has developed radionuclide standardization methods and measurements of the Gamma-ray emission probabilities per decay by means of 4πβ-γ coincidence system, a high accuracy primary method for determining disintegration rate of radionuclides of interest. In 2001 the LNM started a research field on modeling, based on Monte Carlo method, of all the system components, including radiation detectors and radionuclide decay processes. This methodology allows the simulation of the detection process in a 4πβ-γ system, determining theoretically the observed activity as a function of the 4πβ detector efficiency, enabling the prediction of the behavior of the extrapolation curve and optimizing a detailed planning of the experiment before starting the measurements. One of the objectives of the present work is the improvement of the 4π proportional counter modeling, presenting a detailed description of the source holder and radioactive source material, as well as absorbers placed around the source. The simulation of radiation transport through the detectors has been carried out using code MCNPX. The main focus of the present work is on Monte Carlo modeling of the standardization of positron emitting radionuclides associated (or not) with electron capture and accompanied (or not) by the emission of Gamma radiation. One difficulty in this modeling is to simulate the detection of the annihilation Gamma ray, which arise in the process of positron absorption within the 4π detector. The methodology was applied to radionuclides 18 F and 22 Na. (author)

  16. Determination of 137Cs activity in soil from Qatar using high-resolution gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Al-Sulaiti, Huda; Nasir, Tabassum; Al Mugren, K.S.; Alkhomashi, N.; Al-Dahan, N.; Al-Dosari, M.; Bradley, D.A.; Bukhari, S.; Matthews, M.; Regan, P.H.; Santawamaitre, T.; Malain, D.; Habib, A.; Al-Dosari, Hanan; Al Sadig, Ibrahim

    2016-01-01

    With interest in establishing baseline concentrations of 137 Cs in soil from the Qatarian peninsula, we focus on determination of the activity concentrations in 129 soil samples collected across the State of Qatar prior to the 2011 Fukushima Dai-ichi nuclear power plant accident. As such, the data provides the basis of a reference map for the detection of releases of this fission product. The activity concentrations were measured via high-resolution gamma-ray spectrometry using a hyper-pure germanium detector enclosed in a copper-lined passive lead shield that was situated in a low-background environment. The activity concentrations ranged from 0.21 to 15.41 Bq/kg, with a median value of 1 Bq/kg, the greatest activity concentration being observed in a sample obtained from northern Qatar. Although it cannot be confirmed, it is expected that this contamination is mainly due to releases from the Chernobyl accident of 26 April 1986, there being a lack of data from Qatar before the accident. The values are typically within but are sometimes lower than the range indicated by data from other countries in the region. The lower values than those of others is suggested to be due to variation in soil characteristics as well as metrological factors at the time of deposition. - Highlights: • A baseline for the radionuclide 137 Cs in soil samples collected from Qatar was established. • 129 soil samples collected across the landscape. • Samples were collected before the most recent accident “the 2011 Fukushima Dai-ichi NNP accident”. • The highest activity concentration was found to be 15.41±0.67 Stat. and 0.11 Syst. • The relatively high concentrations can be attributed to rain washout.

  17. Multi-messenger Light Curves from Gamma-Ray Bursts in the Internal Shock Model

    Energy Technology Data Exchange (ETDEWEB)

    Bustamante, Mauricio [Center for Cosmology and AstroParticle Physics (CCAPP), The Ohio State University, Columbus, OH 43210 (United States); Heinze, Jonas; Winter, Walter [Deutsches Elektronen-Synchrotron (DESY), Platanenallee 6, D-15738 Zeuthen (Germany); Murase, Kohta, E-mail: bustamanteramirez.1@osu.edu, E-mail: walter.winter@desy.de, E-mail: jonas.heinze@desy.de, E-mail: murase@psu.edu [Center for Particle and Gravitational Astrophysics, The Pennsylvania State University, University Park, PA16802 (United States)

    2017-03-01

    Gamma-ray bursts (GRBs) are promising as sources of neutrinos and cosmic rays. In the internal shock scenario, blobs of plasma emitted from a central engine collide within a relativistic jet and form shocks, leading to particle acceleration and emission. Motivated by present experimental constraints and sensitivities, we improve the predictions of particle emission by investigating time-dependent effects from multiple shocks. We produce synthetic light curves with different variability timescales that stem from properties of the central engine. For individual GRBs, qualitative conclusions about model parameters, neutrino production efficiency, and delays in high-energy gamma-rays can be deduced from inspection of the gamma-ray light curves. GRBs with fast time variability without additional prominent pulse structure tend to be efficient neutrino emitters, whereas GRBs with fast variability modulated by a broad pulse structure can be inefficient neutrino emitters and produce delayed high-energy gamma-ray signals. Our results can be applied to quantitative tests of the GRB origin of ultra-high-energy cosmic rays, and have the potential to impact current and future multi-messenger searches.

  18. Multi-messenger light curves from gamma-ray bursts in the internal shock model

    Energy Technology Data Exchange (ETDEWEB)

    Bustamante, Mauricio [Ohio State Univ., Columbus, OH (United States). Center for Cosmology and AstroParticle Physics (CCAPP); Ohio State Univ., Columbus, OH (United States). Dept. of Physics; Murase, Kohta [Pennsylvania State Univ., University Park, PA (United States). Center for Particle and Gravitational Astrophysics; Pennsylvania State Univ., University Park, PA (United States). Dept. of Astronomy and Astrophysics; Winter, Walter [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2016-06-15

    Gamma-ray bursts (GRBs) are promising as sources of neutrinos and cosmic rays. In the internal shock scenario, blobs of plasma emitted from a central engine collide within a relativistic jet and form shocks, leading to particle acceleration and emission. Motivated by present experimental constraints and sensitivities, we improve the predictions of particle emission by investigating time-dependent effects from multiple shocks. We produce synthetic light curves with different variability timescales that stem from properties of the central engine. For individual GRBs, qualitative conclusions about model parameters, neutrino production efficiency, and delays in high-energy gamma rays can be deduced from inspection of the gamma-ray light curves. GRBs with fast time variability without additional prominent pulse structure tend to be efficient neutrino emitters, whereas GRBs with fast variability modulated by a broad pulse structure tend to be inefficient neutrino emitters and produce delayed high-energy gamma-ray signals. Our results can be applied to quantitative tests of the GRB origin of ultra-high-energy cosmic rays, and have the potential to impact current and future multi-messenger searches.

  19. Standard test method for gamma energy emission from fission products in uranium hexafluoride and uranyl nitrate solution

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the measurement of gamma energy emitted from fission products in uranium hexafluoride (UF6) and uranyl nitrate solution. It is intended to provide a method for demonstrating compliance with UF6 specifications C 787 and C 996 and uranyl nitrate specification C 788. 1.2 The lower limit of detection is 5000 MeV Bq/kg (MeV/kg per second) of uranium and is the square root of the sum of the squares of the individual reporting limits of the nuclides to be measured. The limit of detection was determined on a pure, aged natural uranium (ANU) solution. The value is dependent upon detector efficiency and background. 1.3 The nuclides to be measured are106Ru/ 106Rh, 103Ru,137Cs, 144Ce, 144Pr, 141Ce, 95Zr, 95Nb, and 125Sb. Other gamma energy-emitting fission nuclides present in the spectrum at detectable levels should be identified and quantified as required by the data quality objectives. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its us...

  20. Investigation of self-powered gamma flux detectors with Lead(II) oxide serving as both emitter and insulator

    International Nuclear Information System (INIS)

    Shi, H.; Yue, S.; Jonkmans, G.; Sur, B.; Hilborn, J.

    2010-01-01

    The use of Lead(II) oxide as the electron-emitting component and the insulating component of self-powered flux detectors is a concept that had not been previously explored. Detectors constructed from various combinations of electrodes (stainless steel, Al, Pb, and W) and insulating materials (Al 2 O 3 and PbO) were irradiated in a 427 Gy/h gamma field. Although high gamma sensitivities were achieved, PbO did not prove to be a strong emitter of gamma-induced electrons. Nevertheless, PbO did serve as a better insulator than one that is currently in use, namely alumina. (author)

  1. Gamma-ray detection and Compton camera image reconstruction with application to hadron therapy

    International Nuclear Information System (INIS)

    Frandes, M.

    2010-09-01

    A novel technique for radiotherapy - hadron therapy - irradiates tumors using a beam of protons or carbon ions. Hadron therapy is an effective technique for cancer treatment, since it enables accurate dose deposition due to the existence of a Bragg peak at the end of particles range. Precise knowledge of the fall-off position of the dose with millimeters accuracy is critical since hadron therapy proved its efficiency in case of tumors which are deep-seated, close to vital organs, or radio-resistant. A major challenge for hadron therapy is the quality assurance of dose delivery during irradiation. Current systems applying positron emission tomography (PET) technologies exploit gamma rays from the annihilation of positrons emitted during the beta decay of radioactive isotopes. However, the generated PET images allow only post-therapy information about the deposed dose. In addition, they are not in direct coincidence with the Bragg peak. A solution is to image the complete spectrum of the emitted gamma rays, including nuclear gamma rays emitted by inelastic interactions of hadrons to generated nuclei. This emission is isotropic, and has a spectrum ranging from 100 keV up to 20 MeV. However, the measurement of these energetic gamma rays from nuclear reactions exceeds the capability of all existing medical imaging systems. An advanced Compton scattering detection method with electron tracking capability is proposed, and modeled to reconstruct the high-energy gamma-ray events. This Compton detection technique was initially developed to observe gamma rays for astrophysical purposes. A device illustrating the method was designed and adapted to Hadron Therapy Imaging (HTI). It consists of two main sub-systems: a tracker where Compton recoiled electrons are measured, and a calorimeter where the scattered gamma rays are absorbed via the photoelectric effect. Considering a hadron therapy scenario, the analysis of generated data was performed, passing trough the complete

  2. Endonuclease activities in extracts of Micrococcus luteus that act on. gamma. -irradiated DNA

    Energy Technology Data Exchange (ETDEWEB)

    Schoen-Bopp, A; Schaefer, G; Hagen, U [Kernforschungszentrum Karlsruhe (Germany, F.R.). Inst. fuer Strahlenbiologie

    1977-03-01

    Several protein fractions containing endonuclease activity against ..gamma..-irradiated DNA (..gamma..-endonuclease) were isolated from M.luteus. The crude extract was eluted on a phosphocellulose column and chromatographed on TEAE cellulose and subsequently on hydroxypatite. Five peaks of ..gamma..-endonuclease were obtained from each preparation. Repeated experiments showed comparable chromatographic behaviour of the fractions. There was no detectable activity of uv-endonuclease in the fractions with ..gamma..-endonuclease but a small contamination of endonuclease against unirradiated DNA and against DNA with apurinic sites. The ..gamma..-endonuclease was stimulated by, but was not dependent on, magnesium. Several tests for endonuclease activity have been used: the analysis of strand breaks in calf-thymus DNA or in PM2 DNA, and the determination of end-groups formed by endonuclease, either 3'OH end-groups or phosphomonoester end groups. From the results obtained it can be assumed that the strand breaks induced by the ..gamma..-endonuclease carry 3'OH and 5' phosphate end groups.

  3. Preparation of [35S]sulfobromophthalein of high specific activity

    International Nuclear Information System (INIS)

    Kurisu, H.; Nilprabhassorn, P.; Wolkoff, A.W.

    1989-01-01

    Study of the hepatocyte transport mechanism of organic anions such as bilirubin and sulfobromophthalein has been limited by the relatively low specific activities of these ligands. [ 3 H]Bilirubin and [ 35 S]sulfobromophthalein have been available with specific activities of only approximately 100 mCi/mmol. We now report a relatively simple procedure to prepare [ 35 S]sulfobromophthalein at a specific activity of approximately 3000 mCi/mmol. This compound is radiochemically pure and serves as a tracer for authentic sulfobromophthalein as judged by chromatography, hepatocyte uptake, metabolism, and biliary excretion. Use of this material as a photoaffinity probe and as a transported ligand may permit dissection and understanding of its transport mechanism

  4. High-energy gamma-ray beams from Compton-backscattered laser light

    Energy Technology Data Exchange (ETDEWEB)

    Sandorfi, A.M.; LeVine, M.J.; Thorn, C.E.; Giordano, G.; Matone, G.

    1983-01-01

    Collisions of light photons with relativistic electrons have previously been used to produce polarized ..gamma..-ray beams with modest (-10%) resolution but relatively low intensity. In contrast, the LEGS project (Laser + Electron Gamma Source) at Brookhaven will produce a very high flux (>2 x 10/sup 7/ s/sup -1/) of background-free polarized ..gamma.. rays whose energy will be determined to a high accuracy (..delta..E = 2.3 MeV). Initially, 300(420)-MeV ..gamma.. rays will be produced by backscattering uv light from the new 2.5(3.0)-GeV X-ray storage ring of the National Synchrotron Light Source (NSLS). The LEGS facility will operate as one of many passive users of the NSLS. In a later stage of the project, a Free Electron Laser is expectred to extend the ..gamma..-ray energy up to 700 MeV.

  5. Equipment for automatic measurement of gamma activity distribution in a column

    International Nuclear Information System (INIS)

    Kalincak, M.; Machan, V.; Vilcek, S.; Balkovsky, K.

    1978-01-01

    The design of a device for stepwise scanning of gamma activity distributions along chromatographic columns is described. In connection with a single-channel gamma spectrometer and a counting ratemeter with a recorder this device permits the resolution of a number of gamma emitters on the column, the determination of the gamma nuclide content in different chemical forms in the sample by means of column separation methods - Gel Chromatography Columns Scanning Method - and the determination of gamma nuclide distribution along the columns. The device permits the scanning of columns of up to 20 mm in diameter and 700 mm in length and continual scanning over a 450 mm column length with one clamping. With minor adaptations it is possible to scan columns up to 30 mm in diameter. The length of the scanned sections is 5 or 10 mm, the scanning time setting is arbitrary and variable activity levels and radiation energies may be measured. (author)

  6. Gamma-ray detection and Compton camera image reconstruction with application to hadron therapy; Detection des rayons gamma et reconstruction d'images pour la camera Compton: Application a l'hadrontherapie

    Energy Technology Data Exchange (ETDEWEB)

    Frandes, M.

    2010-09-15

    A novel technique for radiotherapy - hadron therapy - irradiates tumors using a beam of protons or carbon ions. Hadron therapy is an effective technique for cancer treatment, since it enables accurate dose deposition due to the existence of a Bragg peak at the end of particles range. Precise knowledge of the fall-off position of the dose with millimeters accuracy is critical since hadron therapy proved its efficiency in case of tumors which are deep-seated, close to vital organs, or radio-resistant. A major challenge for hadron therapy is the quality assurance of dose delivery during irradiation. Current systems applying positron emission tomography (PET) technologies exploit gamma rays from the annihilation of positrons emitted during the beta decay of radioactive isotopes. However, the generated PET images allow only post-therapy information about the deposed dose. In addition, they are not in direct coincidence with the Bragg peak. A solution is to image the complete spectrum of the emitted gamma rays, including nuclear gamma rays emitted by inelastic interactions of hadrons to generated nuclei. This emission is isotropic, and has a spectrum ranging from 100 keV up to 20 MeV. However, the measurement of these energetic gamma rays from nuclear reactions exceeds the capability of all existing medical imaging systems. An advanced Compton scattering detection method with electron tracking capability is proposed, and modeled to reconstruct the high-energy gamma-ray events. This Compton detection technique was initially developed to observe gamma rays for astrophysical purposes. A device illustrating the method was designed and adapted to Hadron Therapy Imaging (HTI). It consists of two main sub-systems: a tracker where Compton recoiled electrons are measured, and a calorimeter where the scattered gamma rays are absorbed via the photoelectric effect. Considering a hadron therapy scenario, the analysis of generated data was performed, passing trough the complete

  7. Gamma-ray induced doppler broadening

    International Nuclear Information System (INIS)

    Robinson, S.J.

    1992-01-01

    The ultra high resolving power of the GAMS4 double-flat crystal spectrometer (M.S. Dewey et al Nucl. Instrum. Methods A 284 (1989) 151.) has been used to observe the Doppler broadening of gamma-rays emitted by nuclei recoiling at speeds as low as 10 -6 c. Such recoils may be induced by the previous emission of gamma-radiation following thermal neutron capture. If the population mechanism of an excited state is known (or can be approximated) and the slowing down mechanism can be modeled, then this technique can be used to extract the lifetime of excited nuclear states. The combination of this technique and the neutron capture reaction allows the study of states which cannot necessarily be accessed by other means. This has allowed the resolution of a number of long standing questions in low-spin nuclear structure. The basis of the technique is discussed and a number of examples given

  8. Dynamics of large-scale cortical interactions at high gamma frequencies during word production: event related causality (ERC) analysis of human electrocorticography (ECoG).

    Science.gov (United States)

    Korzeniewska, Anna; Franaszczuk, Piotr J; Crainiceanu, Ciprian M; Kuś, Rafał; Crone, Nathan E

    2011-06-15

    Intracranial EEG studies in humans have shown that functional brain activation in a variety of functional-anatomic domains of human cortex is associated with an increase in power at a broad range of high gamma (>60Hz) frequencies. Although these electrophysiological responses are highly specific for the location and timing of cortical processing and in animal recordings are highly correlated with increased population firing rates, there has been little direct empirical evidence for causal interactions between different recording sites at high gamma frequencies. Such causal interactions are hypothesized to occur during cognitive tasks that activate multiple brain regions. To determine whether such causal interactions occur at high gamma frequencies and to investigate their functional significance, we used event-related causality (ERC) analysis to estimate the dynamics, directionality, and magnitude of event-related causal interactions using subdural electrocorticography (ECoG) recorded during two word production tasks: picture naming and auditory word repetition. A clinical subject who had normal hearing but was skilled in American Signed Language (ASL) provided a unique opportunity to test our hypothesis with reference to a predictable pattern of causal interactions, i.e. that language cortex interacts with different areas of sensorimotor cortex during spoken vs. signed responses. Our ERC analyses confirmed this prediction. During word production with spoken responses, perisylvian language sites had prominent causal interactions with mouth/tongue areas of motor cortex, and when responses were gestured in sign language, the most prominent interactions involved hand and arm areas of motor cortex. Furthermore, we found that the sites from which the most numerous and prominent causal interactions originated, i.e. sites with a pattern of ERC "divergence", were also sites where high gamma power increases were most prominent and where electrocortical stimulation mapping

  9. Development of Simultaneous Beta-and-Coincidence-Gamma Imager for Plant Imaging Research

    Energy Technology Data Exchange (ETDEWEB)

    Tai, Yuan-Chuan [Washington Univ., St. Louis, MO (United States). School of Medicine

    2016-09-30

    The goal of this project is to develop a novel imaging system that can simultaneously acquire beta and coincidence gamma images of positron sources in thin objects such as leaves of plants. This hybrid imager can be used to measure carbon assimilation in plants quantitatively and in real-time after C-11 labeled carbon-dioxide is administered. A better understanding of carbon assimilation, particularly under the increasingly elevated atmospheric CO2 level, is extremely critical for plant scientists who study food crop and biofuel production. Phase 1 of this project is focused on the technology development with 3 specific aims: (1) develop a hybrid detector that can detect beta and gamma rays simultaneously; (2) develop an imaging system that can differentiate these two types of radiation and acquire beta and coincidence gamma images in real-time; (3) develop techniques to quantify radiotracer distribution using beta and gamma images. Phase 2 of this project is to apply technologies developed in phase 1 to study plants using positron-emitting radionuclide such as 11C to study carbon assimilation in biofuel plants.

  10. Loss of consciousness is related to hyper-correlated gamma-band activity in anesthetized macaques and sleeping humans.

    Science.gov (United States)

    Bola, Michał; Barrett, Adam B; Pigorini, Andrea; Nobili, Lino; Seth, Anil K; Marchewka, Artur

    2018-02-15

    Loss of consciousness can result from a wide range of causes, including natural sleep and pharmacologically induced anesthesia. Important insights might thus come from identifying neuronal mechanisms of loss and re-emergence of consciousness independent of a specific manipulation. Therefore, to seek neuronal signatures of loss of consciousness common to sleep and anesthesia we analyzed spontaneous electrophysiological activity recorded in two experiments. First, electrocorticography (ECoG) acquired from 4 macaque monkeys anesthetized with different anesthetic agents (ketamine, medetomidine, propofol) and, second, stereo-electroencephalography (sEEG) from 10 epilepsy patients in different wake-sleep stages (wakefulness, NREM, REM). Specifically, we investigated co-activation patterns among brain areas, defined as correlations between local amplitudes of gamma-band activity. We found that resting wakefulness was associated with intermediate levels of gamma-band coupling, indicating neither complete dependence, nor full independence among brain regions. In contrast, loss of consciousness during NREM sleep and propofol anesthesia was associated with excessively correlated brain activity, as indicated by a robust increase of number and strength of positive correlations. However, such excessively correlated brain signals were not observed during REM sleep, and were present only to a limited extent during ketamine anesthesia. This might be related to the fact that, despite suppression of behavioral responsiveness, REM sleep and ketamine anesthesia often involve presence of dream-like conscious experiences. We conclude that hyper-correlated gamma-band activity might be a signature of loss of consciousness common across various manipulations and independent of behavioral responsiveness. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. On the Preparation of Working Standards for Gamma-Ray Spectrometry

    International Nuclear Information System (INIS)

    Durasevic, M.; Kandic, A.; Milosevic, Z.; Seslak, B.; Vukanac, I.

    2013-01-01

    In the Laboratory for Radionuclide Metrology at Vinca Institute, activity concentration measurements are routinely performed and numerous calibration standards are required. Thus, a variety of calibration standards whose measurement geometry and chemical composition and density are similar to those of the measured samples were prepared. The standardized solutions of a common mixture of gamma-emitting radionuclides (241Am, 109Cd, 139Ce, 57Co, 60Co,137Cs, 203Hg, 113Sn, 85Sr, 88Y and 210Pb) purchased at the Czech Metrological Institute were used to prepare working standards for efficiency and energy calibration of gamma-ray semiconductor HPGe spectrometer in accordance with the IAEA recommendations. Calibration standards were prepared in different geometries (PVC cylindrical boxes, Marinelly beakers and PVC cylindrical bottles) and with various matrices (mineralized grass, activated carbon, surface soil, water, sand and ached filter paper). The matrix materials were spiked by using the activated carbon as the activity carrier, and homogenized mechanically. A comprehensive review of the procedures and techniques used for working standard preparation is presented in this paper.(author)

  12. Crystalline nanotubes of {gamma}-AlOOH and {gamma}-Al{sub 2}O{sub 3}: hydrothermal synthesis, formation mechanism and catalytic performance

    Energy Technology Data Exchange (ETDEWEB)

    Lu, C L; Lv, J G; Xu, L; Guo, X F; Hou, W H [Key Laboratory of Mesoscopic Chemistry of MOE, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China); Hu, Y; Huang, H [State Key Laboratory of Materials-Oriented Chemical Engineering, Nanjing University of Technology, Nanjing 210009 (China)], E-mail: guoxf@nju.edu.cn, E-mail: whou@nju.edu.cn

    2009-05-27

    Crystalline nanotubes of {gamma}-AlOOH and {gamma}-Al{sub 2}O{sub 3} have been synthesized. An anionic surfactant-assisted hydrothermal process yields {gamma}-AlOOH nanotubes, and appropriate calcination treatment of the {gamma}-AlOOH nanotubes yields {gamma}-Al{sub 2}O{sub 3} nanotubes. The nanotubes were characterized by XRD, SEM, TEM, TG-DSC, FTIR and nitrogen adsorption-desorption techniques. Both the {gamma}-AlOOH and {gamma}-Al{sub 2}O{sub 3} nanotubes are crystalline, with a representative length of {approx}500 nm and diameters of 20-40 nm. The {gamma}-Al{sub 2}O{sub 3} nanotubes exhibit a very high mesoporous specific surface area (SSA) of 201.0 m{sup 2} g{sup -1} and a high mesopore volume of 0.68 cm{sup 3} g{sup -1} with an average mesopore size of 27.7 nm, as well as a high microporous SSA of 186.0 m{sup 2} g{sup -1} and a micropore volume of 0.08 cm{sup 3} g{sup -1} with an average micropore size of 0.53 nm. The formation process was discussed and a possible mechanism was proposed, in which a lamellar phase was first formed by camphorsulfonic anions and Al(III) species, and then rolled up to form the crystalline nanotubes under the hydrothermal condition. The catalytic performance of the obtained {gamma}- Al{sub 2}O{sub 3} nanotubes was tested by using the dehydration of ethanol to ethylene as a probe reaction and it was shown that the obtained {gamma}- Al{sub 2}O{sub 3} nanotubes catalyst possesses a higher catalytic activity compared with the {gamma}- Al{sub 2}O{sub 3} nanoparticles.

  13. Natural radioactivity investigation in Dam sediments of northeast Algeria using gamma spectroscopy

    Directory of Open Access Journals (Sweden)

    Benrachi Fatima

    2017-01-01

    Full Text Available Current research paper intends to estimate the natural radioactivity levels in sediments samples collected from Beni Haroun Dam in the northeast Algeria, using high resolution HPGe detector. The mean activity concentrations values measured for the radionuclides 232Th, 226Ra and 40K are 18.9 ± 1.9, 37.3 ± 2.7 and 149.9 ± 5.5 Bq/kg, respectively. The 137Cs anthropogenic radionuclide has been observed with maximum activity concentration value of 0.8 ± 0.4 Bq/kg, which is considered an insignificant amount. In order to assess the radiological threat of gamma radiations emitted by these radionuclides on the health of the population, absorbed dose rate, annual effective dose equivalent and radiation hazard indices were had been calculated. The obtained values are compared with the world wide average ones.

  14. Acridinium esters as high-specific-activity labels in immunoassay

    International Nuclear Information System (INIS)

    Weeks, I.; Beheshti, I.; McCapra, F.; Campbell, A.K.; Woodhead, J.S.

    1983-01-01

    A chemiluminescent acridinium ester has been synthesized that reacts spontaneously with proteins to yield stable, immunoreactive derivatives of high specific activity. The compound has been used to prepare chemiluminescent monoclonal antibodies to human alpha 1-fetoprotein having average incorporation ratios as great as 2.8 mol of label per mole of antibody, which corresponds to a detection limit of approximately 8 X 10(-19) mol. These antibodies have been used in the preliminary development of a two-site immunochemiluminometric assay for human alpha 1-fetoprotein, which requires only a 30-min incubation and a quantification time of 5 s per sample

  15. Determination of low specific activity iodine-129 off-gas concentrations by GC separation and negative ionization mass spectrometry

    International Nuclear Information System (INIS)

    Fernandez, S.J.; Rankin, R.A.; McManus, G.J.; Nielsen, R.A.; Delmore, J.E.; Hohorst, F.A.; Murphy, L.P.

    1983-09-01

    This document is the final report of the laboratory development of a method for determining the specific activity of the 129 I emitted from a nuclear fuel reprocessing plant. The technique includes cryogenic sample collection, chemical form separation, quantitation by gas chromatography, and specific activity measurement of each chemical species by negative ionization mass spectrometry. The major conclusions were that both organic and elemental iodine can be quantitatively collected without fractionation and that specific activity measurements as low as one atom of 129 I per 10 5 atoms of 127 I are possible

  16. High-efficiency orange and tandem white organic light-emitting diodes using phosphorescent dyes with horizontally oriented emitting dipoles.

    Science.gov (United States)

    Lee, Sunghun; Shin, Hyun; Kim, Jang-Joo

    2014-09-03

    Tandem white organic light-emitting diodes (WOLEDs) using horizontally oriented phosphorescent dyes in an exciplex-forming co-host are presented, along with an orange OLED. A high external quantum efficiency of 32% is achieved for the orange OLED at 1000 cd m(-2) and the tandem WOLEDs exhibit a high maximum EQE of 54.3% (PE of 63 lm W(-1)). © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Portable high energy gamma ray imagers

    International Nuclear Information System (INIS)

    Guru, S.V.; Squillante, M.R.

    1996-01-01

    To satisfy the needs of high energy gamma ray imagers for industrial nuclear imaging applications, three high energy gamma cameras are presented. The RMD-Pinhole camera uses a lead pinhole collimator and a segmented BGO detector viewed by a 3 in. square position sensitive photomultiplier tube (PSPMT). This pinhole gamma camera displayed an energy resolution of 25.0% FWHM at the center of the camera at 662 keV and an angular resolution of 6.2 FWHM at 412 keV. The fixed multiple hole collimated camera (FMCC), used a multiple hole collimator and a continuous slab of NaI(Tl) detector viewed by the same PSPMT. The FMCC displayed an energy resolution of 12.4% FWHM at 662 keV at the center of the camera and an angular resolution of 6.0 FWHM at 412 keV. The rotating multiple hole collimated camera (RMCC) used a 180 antisymmetric rotation modulation collimator and CsI(Tl) detectors coupled to PIN silicon photodiodes. The RMCC displayed an energy resolution of 7.1% FWHM at 662 keV and an angular resolution of 4.0 FWHM at 810 keV. The performance of these imagers is discussed in this paper. (orig.)

  18. Gamma irradiation enhances biological activities of mulberry leaf extract

    International Nuclear Information System (INIS)

    Cho, Byoung-Ok; Che, Denis Nchang; Yin, Hong-Hua; Jang, Seon-Il

    2017-01-01

    The purpose of this study was to investigate the influence of irradiation on the anti-oxidative, anti-inflammatory and whitening effects of mulberry leaf extract. This was done by comparing the phenolic contents; 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging effects; 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulphonicacid) (ABTS) radical scavenging effects; in vitro tyrosinase inhibitory effects and the production of IL-6, TNF-α, PGE 2 , and NO in lipopolysaccharide-stimulated RAW264.7 macrophages and the production of IL-6 and TNF-α in phorbol 12-myristate 13-acetate plus calcium ionophore A23187-stimulated HMC-1 cells, respectively. The results showed that irradiated mulberry leaf extract possesses more anti-oxidant, anti-inflammatory, and tyrosinase inhibitory activities than their non-irradiated counterpart, probably due to increase in phenolic contents induced by gamma irradiation at dose of 10kGy. This research stresses on the importance of irradiation in functional foods. - Highlights: • Gamma-irradiated mulberry leaf extract enhanced in vitro antioxidant activities. • Gamma-irradiated mulberry leaf extract enhanced in vitro tyrosinase inhibitory effects. • Gamma-irradiated mulberry leaf extract treatment reduced the production of IL-6, TNF-α, PGE 2 , and NO.

  19. Highly efficient single-layer dendrimer light-emitting diodes with balanced charge transport

    Science.gov (United States)

    Anthopoulos, Thomas D.; Markham, Jonathan P. J.; Namdas, Ebinazar B.; Samuel, Ifor D. W.; Lo, Shih-Chun; Burn, Paul L.

    2003-06-01

    High-efficiency single-layer-solution-processed green light-emitting diodes based on a phosphorescent dendrimer are demonstrated. A peak external quantum efficiency of 10.4% (35 cd/A) was measured for a first generation fac-tris(2-phenylpyridine) iridium cored dendrimer when blended with 4,4'-bis(N-carbazolyl)biphenyl and electron transporting 1,3,5-tris(2-N-phenylbenzimidazolyl)benzene at 8.1 V. A maximum power efficiency of 12.8 lm/W was measured also at 8.1 V and 550 cd/m2. These results indicate that, by simple blending of bipolar and electron-transporting molecules, highly efficient light-emitting diodes can be made employing a very simple device structure.

  20. Spectroscopic gamma camera for use in high dose environments

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Yuichiro, E-mail: yuichiro.ueno.bv@hitachi.com [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Fujishima, Yasutake; Kometani, Yutaka [Hitachi Works, Hitachi-GE Nuclear Energy, Ltd., Hitachi-shi, Ibaraki-ken (Japan); Suzuki, Yasuhiko [Measuring Systems Engineering Dept., Hitachi Aloka Medical, Ltd., Ome-shi, Tokyo (Japan); Umegaki, Kikuo [Faculty of Engineering, Hokkaido University, Sapporo-shi, Hokkaido (Japan)

    2016-06-21

    We developed a pinhole gamma camera to measure distributions of radioactive material contaminants and to identify radionuclides in extraordinarily high dose regions (1000 mSv/h). The developed gamma camera is characterized by: (1) tolerance for high dose rate environments; (2) high spatial and spectral resolution for identifying unknown contaminating sources; and (3) good usability for being carried on a robot and remotely controlled. These are achieved by using a compact pixelated detector module with CdTe semiconductors, efficient shielding, and a fine resolution pinhole collimator. The gamma camera weighs less than 100 kg, and its field of view is an 8 m square in the case of a distance of 10 m and its image is divided into 256 (16×16) pixels. From the laboratory test, we found the energy resolution at the 662 keV photopeak was 2.3% FWHM, which is enough to identify the radionuclides. We found that the count rate per background dose rate was 220 cps h/mSv and the maximum count rate was 300 kcps, so the maximum dose rate of the environment where the gamma camera can be operated was calculated as 1400 mSv/h. We investigated the reactor building of Unit 1 at the Fukushima Dai-ichi Nuclear Power Plant using the gamma camera and could identify the unknown contaminating source in the dose rate environment that was as high as 659 mSv/h.

  1. Heat transfer and structure stress analysis of micro packaging component of high power light emitting diode

    Directory of Open Access Journals (Sweden)

    Hsu Chih-Neng

    2013-01-01

    Full Text Available This paper focuses on the heat transfer and structural stress analysis of the micro- scale packaging structure of a high-power light emitting diode. The thermal-effect and thermal-stress of light emitting diode are determined numerically. Light emitting diode is attached to the silicon substrate through the wire bonding process by using epoxy as die bond material. The silicon substrate is etched with holes at the bottom and filled with high conductivity copper material. The chip temperature and structure stress increase with input power consumption. The micro light emitting diode is mounted on the heat sink to increase the heat dissipation performance, to decrease chip temperature, to enhance the material structure reliability and safety, and to avoid structure failure as well. This paper has successfully used the finite element method to the micro-scale light emitting diode heat transfer and stress concentration at the edges through etched holes.

  2. Time-of-flight discrimination between gamma-rays and neutrons by using artificial neural networks

    International Nuclear Information System (INIS)

    Akkoyun, S.

    2013-01-01

    Highlights: ► Time-of-flight (tof) is an obvious method for separation between gamma and neutron particles. ► tof distributions are obtained by neural networks. ► Neural network method is consistent with the experimental results. ► Neural networks can classify different events for discrimination. - Abstract: In gamma-ray spectroscopy, a number of neutrons are emitted from the nuclei together with the gamma-rays. These neutrons influence gamma-ray spectra. An obvious method for discrimination between neutrons and gamma-rays is based on the time-of-flight (tof) technique. In this work, the tof distributions of gamma-rays and neutrons were obtained both experimentally and by using artificial neural networks (ANNs). It was shown that, ANN can correctly classify gamma-ray and neutron events. Also, for highly nonlinear detector response for tof, we have constructed consistent empirical physical formulas (EPFs) by appropriate ANNs. These ANN–EPFs can be used to derive further physical functions which could be relevant to discrimination between gamma-rays and neutrons

  3. Novel Concrete Chemistry Achieved with Low Dose Gamma Radiation Curing and Resistance to Neutron Activation

    Science.gov (United States)

    Burnham, Steven Robert

    As much as 50% of ageing-related problems with concrete structures can be attributed to con-struction deficiencies at the time of placement. The most influential time affecting longevity of concrete structures is the curing phase, or commonly the initial 28 days following its placement. A novel advanced atomistic analysis of novel concrete chemistry is presented in this dissertation with the objective to improve concrete structural properties and its longevity. Based on experiments and computational models, this novel concrete chemistry is discussed in two cases: (a) concrete chemistry changes when exposed to low-dose gamma radiation in its early curing stage, thus improving its strength in a shorter period of time then curing for the conventional 28 days; (b) concrete chemistry is controlled by its atomistic components to assure strength is not reduced but that its activation due to long-term exposure to neutron flux in nuclear power plants is negligible. High dose gamma radiation is well documented as a degradation mechanism that decreases concrete's compressive strength; however, the effects of low-dose gamma radiation on the initial curing phase of concrete, having never been studied before, proved its compressive strength increases. Using a 137 Cs source, concrete samples were subjected to gamma radiation during the initial curing phase for seven, 14, and 28 days. The compressive strength after seven days is improved for gamma cured concrete by 24% and after 14 days by 76%. Concrete shows no improvement in compressive strength after 28 days of exposure to gamma radiation, showing that there is a threshold effect. Scanning Electron Microscopy is used to examine the microstructure of low-dose gamma radiation where no damage to its microstructure is found, showing no difference between gamma cured and conventionally cured concrete. Molecular dynamics modeling based on the MOPAC package is used to study how gamma radiation during the curing stage improves

  4. Field Deployable Gamma Radiation Detectors for DHS Use

    Energy Technology Data Exchange (ETDEWEB)

    Sanjoy Mukhopadhyay

    2007-08-01

    Recently, the Department of Homeland Security (DHS) has integrated all nuclear detection research, development, testing, evaluation, acquisition, and operational support into a single office: the Domestic Nuclear Detection Office (DNDO). The DNDO has specific requirements set for all commercial off-the-shelf and government off-the-shelf radiation detection equipment and data acquisition systems. This article would investigate several recent developments in field deployable gamma radiation detectors that are attempting to meet the DNDO specifications. Commercially available, transportable, handheld radio isotope identification devices (RIID) are inadequate for DHS requirements in terms of sensitivity, resolution, response time, and reach-back capability. The leading commercial vendor manufacturing handheld gamma spectrometer in the United States is Thermo Electron Corporation. Thermo Electron's identiFINDER{trademark}, which primarily uses sodium iodide crystals (3.18 x 2.54cm cylinders) as gamma detectors, has a Full-Width-at-Half-Maximum energy resolution of 7 percent at 662 keV. Thermo Electron has just recently come up with a reach-back capability patented as RadReachBack{trademark} that enables emergency personnel to obtain real-time technical analysis of radiation samples they find in the field. The current project has the goal to build a prototype handheld gamma spectrometer, equipped with a digital camera and an embedded cell phone to be used as an RIID with higher sensitivity, better resolution, and faster response time (able to detect the presence of gamma-emitting radio isotopes within 5 seconds of approach), which will make it useful as a field deployable tool. The handheld equipment continuously monitors the ambient gamma radiation, and, if it comes across any radiation anomalies with higher than normal gamma gross counts, it sets an alarm condition. When a substantial alarm level is reached, the system automatically triggers the saving of relevant

  5. Field Deployable Gamma Radiation Detectors for DHS Use

    International Nuclear Information System (INIS)

    Sanjoy Mukhopadhyay

    2007-01-01

    Recently, the Department of Homeland Security (DHS) has integrated all nuclear detection research, development, testing, evaluation, acquisition, and operational support into a single office: the Domestic Nuclear Detection Office (DNDO). The DNDO has specific requirements set for all commercial off-the-shelf and government off-the-shelf radiation detection equipment and data acquisition systems. This article would investigate several recent developments in field deployable gamma radiation detectors that are attempting to meet the DNDO specifications. Commercially available, transportable, handheld radio isotope identification devices (RIID) are inadequate for DHS requirements in terms of sensitivity, resolution, response time, and reach-back capability. The leading commercial vendor manufacturing handheld gamma spectrometer in the United States is Thermo Electron Corporation. Thermo Electron's identiFINDER(trademark), which primarily uses sodium iodide crystals (3.18 x 2.54cm cylinders) as gamma detectors, has a Full-Width-at-Half-Maximum energy resolution of 7 percent at 662 keV. Thermo Electron has just recently come up with a reach-back capability patented as RadReachBack(trademark) that enables emergency personnel to obtain real-time technical analysis of radiation samples they find in the field. The current project has the goal to build a prototype handheld gamma spectrometer, equipped with a digital camera and an embedded cell phone to be used as an RIID with higher sensitivity, better resolution, and faster response time (able to detect the presence of gamma-emitting radio isotopes within 5 seconds of approach), which will make it useful as a field deployable tool. The handheld equipment continuously monitors the ambient gamma radiation, and, if it comes across any radiation anomalies with higher than normal gamma gross counts, it sets an alarm condition. When a substantial alarm level is reached, the system automatically triggers the saving of relevant

  6. Gamma ray bursts: Current status of observations and theory

    International Nuclear Information System (INIS)

    Meegan, C.A.

    1990-04-01

    Gamma ray bursts display a wide range of temporal and spectral characteristics, but typically last several seconds and emit most of their energy in a low energy, gamma ray region. The burst sources appear to be isotropically distributed on the sky. Several lines of evidence suggest magnetic neutron stars as sources for bursts. A variety of energy sources and emission mechanisms are proposed

  7. Peroxisome proliferator-activated receptor gamma coactivator-1 alpha acts as a tumor suppressor in hepatocellular carcinoma.

    Science.gov (United States)

    Liu, Rui; Zhang, Haiyang; Zhang, Yan; Li, Shuang; Wang, Xinyi; Wang, Xia; Wang, Cheng; Liu, Bin; Zen, Ke; Zhang, Chen-Yu; Zhang, Chunni; Ba, Yi

    2017-04-01

    Peroxisome proliferator-activated receptor gamma coactivator-1 alpha plays a crucial role in regulating the biosynthesis of mitochondria, which is closely linked to the energy metabolism in various tumors. This study investigated the regulatory role of peroxisome proliferator-activated receptor gamma coactivator-1 alpha in the pathogenesis of hepatocellular carcinoma. In this study, the changes of peroxisome proliferator-activated receptor gamma coactivator-1 alpha messenger RNA levels between normal human liver and hepatocellular carcinoma tissue were examined by quantitative reverse transcription polymerase chain reaction. Knockdown of peroxisome proliferator-activated receptor gamma coactivator-1 alpha was conducted by RNA interference in the human liver cell line L02, while overexpression of peroxisome proliferator-activated receptor gamma coactivator-1 alpha was conducted by adenovirus encoding peroxisome proliferator-activated receptor gamma coactivator-1 alpha complementary DNA in the human hepatocarcinoma cell line HepG2. Cellular morphological changes were observed via optical and electron microscopy. Cellular apoptosis was determined by Hoechst 33258 staining. In addition, the expression levels of 21,400 genes in tissues and cells were detected by microarray. It was shown that peroxisome proliferator-activated receptor gamma coactivator-1 alpha expression was significantly downregulated in hepatocellular carcinoma compared with normal liver tissues. After knockdown of peroxisome proliferator-activated receptor gamma coactivator-1 alpha expression in L02 cells, cells reverted to immature and dedifferentiated morphology exhibiting cancerous tendency. Apoptosis occurred in the HepG2 cells after transfection by adenovirus encoding peroxisome proliferator-activated receptor gamma coactivator-1 alpha. Microarray analysis showed consistent results. The results suggest that peroxisome proliferator-activated receptor gamma coactivator-1 alpha acts as a tumor

  8. Effect of gamma irradiation on antioxidant activity of Amoora rohitaka

    International Nuclear Information System (INIS)

    Rajurkar, N.S.; Gaikwad, K.N.

    2012-01-01

    The effect of a medium dose of gamma radiation on antioxidant activity of Amoora rohitaka was studied. Radiation doses were 0, 1, 3 and 5 kGy. Antioxidant activity was screened by using different assay. With increasing dose the formation of Maillard reaction products (MRPs) contributes to the increase in the antioxidant activity. MRPs are formed as a result of Maillard reaction. In ABTS [2,2-azino-bis-3-ethylbenzothiazoline-6-sulfonic acid di-ammonium salt] assay, ethanol extract showed increase in scavenging activity. It also showed a marked increase in polyphenolic contents. The present study reveals that gamma irradiation can be an efficient process to increase antioxidant activity of Amoora rohitaka. (author)

  9. Observations and numerical studies of gamma-ray emission in colliding-wind binaries

    International Nuclear Information System (INIS)

    Reitberger, K.

    2014-01-01

    Massive stars in binary systems have long been regarded as potential sources of high-energy gamma rays. The emission is thought to arise in the region where the stellar winds collide, thereby producing accelerated particles which subsequently emit gamma rays.This scenario is supported by observations with the Fermi Large Area Telescope presented in this thesis. To address the underlying emission mechanisms in a quantitative way, numerical simulations that incorporate hydrodynamics, the acceleration of charged particles as well as the subsequent gamma-ray emission were found to be needed.This thesis presents the analysis of a high-energy gamma-ray source and its identification with the particle-accelerating colliding-wind binary system Eta Carinae. In order to go beyond the present understanding of such objects, this work provides detailed description of a new 3D-hydrodynamical model, which incorporates the line-driven acceleration of the winds, gravity, orbital motion and the radiative cooling of the shocked plasma, as well as the diffusive shock acceleration of charged particles in the wind collision region. In a subsequent step we simulate and study the resulting gamma-ray emission via relativistic bremsstrahlung, anisotropic inverse Compton radiation and neutral pion decay. (author) [de

  10. The Gamma-Ray Emitting Radio-Loud Narrow-Line Seyfert 1 Galaxy PKS 2004-447 II. The Radio View

    Science.gov (United States)

    Schulz, R.; Kreikenbohm, A.; Kadler, M.; Ojha, R.; Ros, E.; Stevens, J.; Edwards, P. G.; Carpenter, B.; Elsaesser, D.; Gehrels, N.; hide

    2016-01-01

    Context. gamma-ray-detected radio-loud narrow-line Seyfert 1 (gamma-NLS1) galaxies constitute a small but interesting sample of the gamma-ray-loud AGN. The radio-loudest gamma-NLS1 known, PKS2004447, is located in the southern hemisphere and is monitored in the radio regime by the multiwavelength monitoring programme TANAMI. Aims. We aim for the first detailed study of the radio morphology and long-term radio spectral evolution of PKS2004447, which are essential for understanding the diversity of the radio properties of gamma-NLS1s. Methods. The TANAMI VLBI monitoring program uses the Australian Long Baseline Array (LBA) and telescopes in Antarctica, Chile, New Zealand, and South Africa to monitor the jets of radio-loud active galaxies in the southern hemisphere. Lower resolution radio flux density measurements at multiple radio frequencies over four years of observations were obtained with the Australia Telescope Compact Array (ATCA). Results. The TANAMI VLBI image at 8.4GHz shows an extended one-sided jet with a dominant compact VLBI core. Its brightness temperature is consistent with equipartition, but it is an order of magnitude below other gamma-NLS1s with the sample value varying over two orders of magnitude. We find a compact morphology with a projected large-scale size 11 kpc and a persistent steep radio spectrum with moderate flux-density variability. Conclusions. PKS2004447 appears to be a unique member of the gamma-NLS1 sample. It exhibits blazar-like features, such as a flat featureless X-ray spectrum and a core-dominated, one-sided parsec-scale jet with indications for relativistic beaming. However, the data also reveal properties atypical for blazars, such as a radio spectrum and large-scale size consistent with compact-steep-spectrum (CSS) objects, which are usually associated with young radio sources. These characteristics are unique among all gamma-NLS1s and extremely rare among gamma-ray-loud AGN.

  11. Gamma-emitting radionuclides in the bottom sediments of some Finnish lakes

    International Nuclear Information System (INIS)

    Ilus, E.; Puhakainen, M.; Saxen, R.

    1993-10-01

    In 1988 and 1990 bottom sediment and surface water samples were taken from eight large lakes representing all five categories of deposition regions contaminated by the chernobyl fallout in Finland. All samples were analysed for gamma-emitting radionuclides. The 137 Cs concentrations in surface waters varied in 1988 from 20 to 310 Bq/m 3 and in 1990 from 78 to 170 Bq/m 3 . The other radionuclides of Chernobyl origin detected in water samples were 106 Ru, 125 Sb and 134 Cs. In the sediments the total amount of 137 Cs per square metre varied in 1988 from 1100 to 160 000 Bq/m 2 and in 1990 from 14 000 to 250 000 Bq/m 2 . The maximum values were in Lake Pyhaejaervi. The maximum concentration of 137 Cs in the surface layer of sediment (0-2cm) was 55 700 Bq/kg dry wt in Lake Naesijaervi. In addition to the cesium isotopes 137 Cs and 134 Cs , Chernobyl derived 106 Ru, 125 Sb amd 144 Ce were detected i the surface layer of sediment in most lakes. 54 Mn, 60 Co and 110m Ag were also detected in some lakes situated in the regions most contaminated by the Chernobyl fallout. In 1988 the maximum concentrations of 137 Cs and 134 Cs were in the uppermost layer of sediment (0-2cm) at almost all stations. In 1990, the cesium peaks already occurred at many stations in the second slice (2-5cm), which may indicate downward diffusion of cesium in sediments or mixing of sediment layers during sampling. The most important factors affecting cesium values in sediments were the local amount of deposition and the type of sediment. This study did not reveal any correletion between the maximum depth of the lake and the area of the lake with the cesium amounts in the sediments. (orig.). (23 refs., 10 figs., 6 tabs.)

  12. High dose gamma-ray standard

    International Nuclear Information System (INIS)

    Macrin, R.; Moraru, R.

    1999-01-01

    The high gamma-ray doses produced in a gamma irradiator are used, mainly, for radiation processing, i.e. sterilization of medical products, processing of food, modifications of polymers, irradiation of electronic devices, a.s.o. The used absorbed doses depend on the application and cover the range 10 Gy to 100 MGy. The regulations in our country require that the response of the dosimetry systems, used for the irradiation of food and medical products, be calibrated and traceable to the national standards. In order to be sure that the products receive the desired absorbed dose, appropriate dosimetric measurements must be performed, including the calibration of the dosemeters and their traceability to the national standards. The high dose gamma-ray measurements are predominantly based on the use of reference radiochemical dosemeters. Among them the ferrous sulfate can be used as reference dosemeter for low doses (up to 400 Gy) but due to its characteristics it deserves to be considered a standard dosemeter and to be used for transferring the conventional absorbed dose to other chemical dosemeters used for absorbed doses up to 100 MGy. The study of the ferrous sulfate dosemeter consisted in preparing many batches of solution by different operators in quality assurance conditions and in determining for all batches the linearity, the relative intrinsic error, the repeatability and the reproducibility. The principal results are the following: the linear regression coefficient: 0.999, the relative intrinsic error: max.6 %, the repeatability (for P* = 95 %): max.3 %, the reproducibility (P* = 95%): max.5 %. (authors)

  13. Effects of gamma rays on non-vascular smooth muscles contractions (rat small intestine)

    International Nuclear Information System (INIS)

    Azroony, R.; Ksies, F.; Alya, G.

    2003-03-01

    In this experiment, the contractile response evoked by activating the membranous cholinergic and adrenergic receptors in the smooth muscular fibres isolated from jejunum in rat small intestine is studied. Also the effect of gamma rays on regulating this contractile response after exposing the whole body of the animals to different doses of gamma rays (3, 5 and 7 Gy) emitted from 60 Co source is studied. Results show that irradiation lessens the sensitivity of muscarinic cholinergic receptors to their agonists in a dose dependent manner. And there is an important shift on irradiated rats where the maximum effect of acetylcholine (E max) can be obtained in higher concentrations of acetylcholine. Concerning the effects of gamma rays on adrenergic receptors, our results show that irradiation, also, decreases the sensitivity of α1 adrenergic receptors to their agonists, and this decrease is represented in a decrease of the irradiated muscular fibers response to the inhibitory effect of phenylephrine (more specific to α1 adrenergic receptors than α2 adrenergic receptors) in a dose dependent manner. While we have found that α2 adrenergic receptors have no important effect on regulating the contractile response of the smooth muscular fibers in the rat jejunum neither in smooth muscular fibers isolated from control animals nor in those fibers which where isolated from irradiated animals. (author)

  14. The technique of express vital determination of radiocesium specific activity in muscular tissue of large agricultural animals by means of the TIM-140 radiometer

    International Nuclear Information System (INIS)

    1997-01-01

    The technique is intended for vital determination of cesium 137 specific activity in muscular tissue of large agricultural animals by means of the TIM-140 radiometer. The specific activity is determined using two measurements. With one measurement the gamma radiation detector is located on a lateral surface of coxofemoral part of the animal, and with the second measurement the absorbing gamma radiation screen is placed between the detector and zone of measurement. The external gamma background and useful signal are registered simultaneously. It allows to carry out measurements with a background till 0.05 mR/h without application of external screens

  15. Highlights of GeV Gamma-Ray Astronomy

    Science.gov (United States)

    Thompson, David J.

    2010-01-01

    Because high-energy gamma rays are primarily produced by high-energy particle interactions, the gamma-ray survey of the sky by the Fermi Gamma-ray Space Telescope offers a view of sites of cosmic ray production and interactions. Gamma-ray bursts, pulsars, pulsar wind nebulae, binary sources, and Active Galactic Nuclei are all phenomena that reveal particle acceleration through their gamma-ray emission. Diffuse Galactic gamma radiation, Solar System gamma-ray sources, and energetic radiation from supernova remnants are likely tracers of high-energy particle interactions with matter and photon fields. This paper will present a broad overview of the constantly changing sky seen with the Large Area Telescope (LAT) on the Fermi spacecraft.

  16. The application of computer technique in routine neutron activation analysis using high resolution gamma ray spectrometry

    International Nuclear Information System (INIS)

    Szopa, Z.; Plejewska, M.; Staszelis, J.

    1982-01-01

    A full system of four computer programs for routine - qualitative and quantitative - neutron activation analysis (NAA) using high resolution gamma ray-spectrometry had been elaborated. The structure and possibilities of the ''data flow'' programs i.e. programs DIDPDP and DIDCDC, dedicated for fast and reliable ''off line'' data transfer between the buffer memory of the spectrometric line (9-track magnetic tape) and the fast access memory (disc) of the used computers PDP-11/45 and CYBER-73 had been presented. The structure and organization of the ''data processing'' programs i.e. programs SAWAPS and MAZYG had been presented as well. The utility and reliability of these programs in the case of the large-scale, routine NAA, exampled by analysis of filters with air polutants, had been tested and discussed. Programs are written mainly in FORTRAN. (author)

  17. Surface gamma-ray survey of SX Tank Farm

    International Nuclear Information System (INIS)

    Stromswold, D.C.; Arthur, R.J.

    1996-08-01

    Measurements made over the surface of the SX Tank Farm at Hanford show Cs 137 to be the only significant gamma ray emitting contaminant. A high-purity germanium detector collected the data in the surface survey. Most of the detected radiation originated from specific above ground objects, such as pipes and vents. One area of increased radiation in the north section of the tank farm between tanks SX-102 and SX-105, was apparently due to contamination of the soil by Cs 137. An area of interest near tanks SX-108, SX-111, and SX-112, below which borehole logs has indicated deep Cs 137 contamination, also showed Cs 137 at the surface, but the signal originated mainly from surface objects rather than from contaminated soils. A significant result of the surface survey is the understanding that surface objects with contamination can affect the signal observed by borehole logging tools as they reach the ground surface

  18. High-energy gamma-ray astronomy and the COS-B mission

    International Nuclear Information System (INIS)

    Wills, R.D.

    1977-01-01

    The most significant results in gamma-ray astronomy have been produced by satellite- and balloon-borne instruments sensitive in the range 30 MeV to approximately 10 GeV. The COS-B instrument which is described is typical of this type of detector. For this reason the review of gamma-ray production mechanisms gives greater attention to those processes which are specifically important in that energy range. (orig.) [de

  19. Computer programs for data reduction and interpretation in plutonium and uranium analysis by gamma ray spectrometry

    International Nuclear Information System (INIS)

    Singh, R.K.; Moorthy, A.D.; Babbar, R.K.; Udagatti, S.V.

    1989-01-01

    Non destructive gamma ray have been developed for analysis of isotopic abundances and concentrations of plutonium and uranium in the respective product solutions of a reprocessing plant. The method involves analysis of gamma rays emitted from the sample and uses a multichannel analyser system. Data reduction and interpretation of these techniques are tedious and time consuming. In order to make it possible to use them in routine analysis, computer programs have been developed in HP-BASIC language which can be used in HP-9845B desktop computer. A set of programs, for plutonium estimation by high resolution gamma ray spectrometry and for on-line measurement of uranium by gamma ray spectrometry are described in this report. (author) 4 refs., 3 tabs., 6 figs

  20. Perforin and IFN-gamma do not significantly regulate the virus-specific CD8+ T cell response in the absence of antiviral effector activity

    DEFF Research Database (Denmark)

    Christensen, Jeanette Erbo; Wodarz, Dominik; Christensen, Jan P

    2004-01-01

    Using gene-targeted mice we have investigated whether perforin and/or interferon-gamma exert a direct regulatory effect on the expansion and contraction of antigen-specific CD8(+) T cells following infection with a virus (vesicular stomatitis virus) which is not controlled through these molecular...

  1. Total body-calcium measurements: comparison of two delayed-gamma neutron activation facilities

    International Nuclear Information System (INIS)

    Ma, R.; Ellis, K.J.; Shypailo, R.J.; Pierson, R.N. Jr.

    1999-01-01

    This study compares two independently calibrated delayed-gamma neutron activation (DGNA) facilities, one at the Brookhaven National Laboratory (BNL), Upton, New York, and the other at the Children's Nutrition Research Center (CNRC), Houston, Texas that measure total body calcium (TBCa). A set of BNL phantoms was sent to CNRC for neutron activation analysis, and a set of CNRC phantoms was measured at BNL. Both facilities showed high precision (<2%), and the results were in good agreement, within 5%. (author)

  2. Catalog of gamma-rays unplaced in radioactive decay schemes

    International Nuclear Information System (INIS)

    Narita, Tsutomu; Kitao, Kensuke.

    1991-03-01

    A catalog is made for gamma-rays emitted in decay of radioactive nuclides but not placed in their decay schemes. It consists of two tables. In Table 1, the number of these unplaced gamma-ray components by a nuclide is given together with the fraction of total intensity of these gamma-rays to that of all observed gamma-rays. In Table 2, the unplaced gamma-rays are arranged in order of increasing energy. Each line of this table contains the gamma-ray energy, intensity, nuclide identification, and energies and intensities of the most prominent gamma-rays from the decay of the radionuclides. This catalog is a compilation from Evaluated Nuclear Structure Data File (ENSDF) maintained by National Nuclear Data Center at Brookhaven National Laboratory, of at February 1990. (author)

  3. X-Ray Emission from an Asymmetric Blast Wave and a Massive White Dwarf in the Gamma Ray Emitting Nova V407 CYG

    Science.gov (United States)

    Nelson, Thomas; Donato, Davide; Mukai, Koji; Sokoloski, Jennifer; Chomiuk, Laura

    2012-01-01

    Classical nova events in symbiotic stars, although rare, offer a unique opportunity to probe the interaction between ejecta and a dense environment in stellar explosions. In this work, we use X-ray data obtained with Swift and Suzaku during the recent classical nova outburst in V407 Cyg to explore such an interaction. We find evidence of both equilibrium and non-equilibrium ionization plasmas at the time of peak X-ray brightness, indicating a strong asymmetry in the density of the emitting region. Comparing a simple model to the data, we find that the X-ray evolution is broadly consistent with nova ejecta driving a forward shock into the dense wind of the Mira companion. We detect a highly absorbed soft X-ray component in the spectrum during the first 50 days of the outburst that is consistent with supersoft emission from the nuclear burning white dwarf. The high temperature and short turn off time of this emission component, in addition to the observed breaks in the optical and UV lightcurves, indicate that the white dwarf in the binary is extremely massive. Finally, we explore the connections between the X-ray and GeV-ray evolution, and propose that the gamma ray turn-off is due to the stalling of the forward shock as the ejecta reach the red giant surface.

  4. The holistic analysis of gamma-ray spectra in instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Blaauw, M

    1993-11-15

    The subject is the computerized analysis of the gamma-ray spectra in INAA. This analysis can be separated in three parts: The conversion of the spectra to information on {gamma}-ray energies and their relative intensities (spectrum reduction), the determination of the relation between the intensity of a {gamma}-ray and the amount of the corresponding element present in the sample (standardization) and the attribution of the {gamma}-ray energies to the elements, including the subsequent computation of the amounts of the elements (interpretation). A {gamma}-ray spectrum can be considered to be the linear sum of the {gamma}-ray spectra of the individual radionuclides present in the sample. Knowing the relative activities of the different radionuclides that may be produced by activation of a single element, a {gamma}-ray spectrum in INAA can also be considered to be the linear sum of the spectra of the elements. This principle has hitherto not been used in INAA to analyze the spectra by linear least squares methods, using all {gamma}-ray energies observed in the spectrum. The implementation of this `holistic` approach required that attention be paid to both spectrum reduction, standardization and interpretation. The thesis describes the methods developed for the holistic analysis of {gamma}-ray spectra in INAA, and present results of experimental comparisons between the holistic and other approaches. (orig./HP).

  5. Portable gamma-ray holdup and attributes measurements of high- and variable-burnup plutonium

    International Nuclear Information System (INIS)

    Wenz, T.R.; Russo, P.A.; Miller, M.C.; Menlove, H.O.; Takahashi, S.; Yamamoto, Y.; Aoki, I.

    1991-01-01

    High burnup-plutonium holdup has been assayed quantitatively by low resolution gamma-ray spectrometry. The assay was calibrated with four plutonium standards representing a range of fuel burnup and 241 Am content. Selection of a calibration standard based on its qualitative spectral similarity to gamma-ray spectra of the process material is partially responsible for the success of these holdup measurements. The spectral analysis method is based on the determination of net counts in a single spectral region of interest (ROI). However, the low-resolution gamma-ray assay signal for the high-burnup plutonium includes unknown amounts of contamination from 241 Am. For most needs, the range of calibration standards required for this selection procedure is not available. A new low-resolution gamma-ray spectral analysis procedure for assay of 239 Pu has been developed. The procedure uses the calculated isotope activity ratios and the measured net counts in three spectral ROIs to evaluate and remove the 241 Am contamination from the 239 Pu assay signal on a spectrum-by-spectrum basis. The calibration for the new procedure requires only a single plutonium standard. The procedure also provides a measure of the burnup and age attributes of holdup deposits. The new procedure has been demonstrated using portable gamma-ray spectroscopy equipment for a wide range of plutonium standards and has also been applied to the assay of 239 Pu holdup in a mixed oxide fuel fabrication facility. 10 refs., 5 figs., 3 tabs

  6. Comparative toxicity of four chlorinated dibenzo-p-dioxins (CDDs) and their mixture. Pt. 2. Structure-activity relationships with inhibition of hepatic phosphoenolpyruvate carboxykinase, pyruvate carboxylase, and [gamma]-glutamyl transpeptidase activities

    Energy Technology Data Exchange (ETDEWEB)

    Weber, L.W.D.; Stahl, B.U.; Rozman, K. (Kansas Univ. Medical Center, Dept. of Pharmacology, Toxicology and Therapeutics, Kansas City, KS (United States) GSF, Inst. fuer Toxikologie, Neuherberg (Germany)); Lebofsky, M. (Kansas Univ. Medical Center, Dept. of Pharmacology, Toxicology and Therapeutics, Kansas City, KS (United States)); Kettrup, A. (GSF, Inst. fuer Oekologische Chemie, Neuherberg (Germany))

    1992-08-01

    Male Sprague-Dawley rats were treated with an LD[sub 20], LD[sub 50] and LD[sub 80] respectively, of tetra-, penta-, hexa-, hepta-CDD and a mixture of the four CDDs, all carrying chlorine substituents in the biologically crucial 2,3,7, and 8 positions. Specific activities of two key enzymes of gluconeogenesis, viz, phosphoenolpyruvate carboxylkinase (PEPCK) and pyruvate carboxylase (PC), as well as the activity of the preneoplastic marker enzyme [gamma]-glutamyl transpeptidase ([gamma]-GT), were determined in livers of CDD-treated and ad libitum-fed control animals. PEPCK activity showed evidence for dose-related inhibition on the second day after dosing; PC activity was slightly reduced, whereas [gamma]-GT activity was dose-dependently inhibited. By 8 days after dosing PEPCK activities were dose-dependently decreased after administration of all four CDDs and their mixture. PC activities were significantly reduced, but no dose-response was evident. The activity of [gamma]-GT was dose-dependently inhibited, but only to a value of 25% below control activities. It is concluded that CDDs share a common mechanism of acute toxicity, viz, inhibition of glucocorticoid-dependent enzymes which results in a derailment of intermediary metabolism not compatible with survival of the animals. (orig.).

  7. Gamma irradiation improves the antioxidant activity of Aloe vera (Aloe barbadensis miller) extracts

    International Nuclear Information System (INIS)

    Lee, Eun Mi; Bai, Hyoung-Woo; Lee, Seung Sik; Hong, Sung Hyun; Cho, Jae-Young; Byung, Yeoup Chung

    2012-01-01

    Aloe has been widely used in food products, pharmaceuticals, and cosmetics because of its aromatic and therapeutic properties. In the present study, the ethanolic extracts of aloe gel were gamma-irradiated from 10 to 100 kGy. After gamma irradiation, the color of the ethanolic extracts of aloe gel changed to red; this color persisted up to 40 kGy but disappeared above 50 kGy. Liquid chromatography/mass spectrometry analysis demonstrated the production of a new, unknown compound (m/z=132) after gamma irradiation of the ethanolic extracts of aloe gel. The amount of this unknown compound increased with increasing irradiation up to 80 kGy, and it was degraded at 100 kGy. Interestingly, it was found that gamma irradiation significantly increased the antioxidant activity, as measured by the 1,1-diphenyl-2-picrylhydrazyl-radical scavenging capacity. The antioxidant activity of aloe extract was dramatically increased from 53.9% in the non-irradiated sample to 92.8% in the sample irradiated at 40 kGy. This strong antioxidant activity was retained even at 100 kGy. These results indicate that gamma irradiation of aloe extract can enhance its antioxidant activity through the formation of a new compound. Based on these results, increased antioxidant activity of aloe extracts by gamma rays can be applied to various industries, especially cosmetics, foodstuffs, and pharmaceuticals.

  8. Gamma irradiation improves the antioxidant activity of Aloe vera (Aloe barbadensis miller) extracts

    Science.gov (United States)

    Mi Lee, Eun; Bai, Hyoung-Woo; Sik Lee, Seung; Hyun Hong, Sung; Cho, Jae-Young; Yeoup Chung, Byung

    2012-08-01

    Aloe has been widely used in food products, pharmaceuticals, and cosmetics because of its aromatic and therapeutic properties. In the present study, the ethanolic extracts of aloe gel were gamma-irradiated from 10 to 100 kGy. After gamma irradiation, the color of the ethanolic extracts of aloe gel changed to red; this color persisted up to 40 kGy but disappeared above 50 kGy. Liquid chromatography/mass spectrometry analysis demonstrated the production of a new, unknown compound (m/z=132) after gamma irradiation of the ethanolic extracts of aloe gel. The amount of this unknown compound increased with increasing irradiation up to 80 kGy, and it was degraded at 100 kGy. Interestingly, it was found that gamma irradiation significantly increased the antioxidant activity, as measured by the 1,1-diphenyl-2-picrylhydrazyl-radical scavenging capacity. The antioxidant activity of aloe extract was dramatically increased from 53.9% in the non-irradiated sample to 92.8% in the sample irradiated at 40 kGy. This strong antioxidant activity was retained even at 100 kGy. These results indicate that gamma irradiation of aloe extract can enhance its antioxidant activity through the formation of a new compound. Based on these results, increased antioxidant activity of aloe extracts by gamma rays can be applied to various industries, especially cosmetics, foodstuffs, and pharmaceuticals.

  9. Effects of 60Co gamma radiation on crotamine

    Directory of Open Access Journals (Sweden)

    Boni-Mitake M.

    2001-01-01

    Full Text Available Ionizing radiation can change the molecular structure and affect the biological properties of biomolecules. This has been employed to attenuate animal toxins. Crotamine is a strongly basic polypeptide (pI 10.3 from Crotalus durissus terrificus venom composed of 42 amino acid residues. It induces skeletal muscle spasms leading to a spastic paralysis of hind limbs in mice. The objective of the present study was to carry out a biochemical study and a toxic activity assay on native and irradiated crotamine. Crotamine was purified from C.d. terrificus venom by Sephadex G-100 gel filtration followed by ion-exchange chromatography, and irradiated at 2 mg/ml in 0.15 M NaCl with 2.0 kGy gamma radiation emitted by a 60Co source. The native and irradiated toxins were evaluated in terms of structure and toxic activity (LD50. Irradiation did not change the protein concentration, the electrophoretic profile or the primary structure of the protein although differences were shown by spectroscopic techniques. Gamma radiation reduced crotamine toxicity by 48.3%, but did not eliminate it.

  10. Gamma-ray vulnerability of light-emitting diodes injection-laser diodes and pin-photodiodes for 1.3 μm wavelength-fiber optics

    International Nuclear Information System (INIS)

    Breuze, G.; Serre, J.

    1992-01-01

    With the increasing use of optical data links, it becomes essential to test for radiation vulnerability not only the transmission support - fiber and cable - but also fiber-end electro-optical components that could be exposed to hostile environment. Presently there is a significant number of radiation tests of optical fibers [1,2,3[. Here are only given a few results obtained on gradient index multimode fibers with and without phosphor. These data provide an important contribution to the improvement of all standard electro-optical pigtailed components working on the 1.3 μm wavelength: light-emitting diodes (LED), injection-laser diode modules (LDM) and pin-photodiodes (PD). Multicomponent LDM behaviour under CO 60 exposure was extensively tested. Hardened optical data links allow now to ensure medium data transmission rates on appreciable fiber - lengths despite medium steady - state gamma-ray exposure

  11. High energy photons and neutrinos from gamma ray bursts

    International Nuclear Information System (INIS)

    Dar, A.

    1998-01-01

    The Hubble space telescope has recently discovered thousands of gigantic comet-like objects in a ring around the central star in the nearest planetary nebula. It is suggested that such circumstellar rings exist around most of stars. Collisions of the relativistic debris from gamma ray bursts in dense stellar regions with such gigantic comet-like objects, which have been stripped off from the circumstellar rings by gravitational perturbations, produce detectable fluxes of high energy gamma-rays and neutrinos from gamma ray bursts

  12. Discovery of a Series of Imidazo[4,5-b]pyridines with Dual Activity at Angiotensin II Type 1 Receptor and Peroxisome Proliferator-Activated Receptor-[gamma

    Energy Technology Data Exchange (ETDEWEB)

    Casimiro-Garcia, Agustin; Filzen, Gary F.; Flynn, Declan; Bigge, Christopher F.; Chen, Jing; Davis, Jo Ann; Dudley, Danette A.; Edmunds, Jeremy J.; Esmaeil, Nadia; Geyer, Andrew; Heemstra, Ronald J.; Jalaie, Mehran; Ohren, Jeffrey F.; Ostroski, Robert; Ellis, Teresa; Schaum, Robert P.; Stoner, Chad (Pfizer)

    2013-03-07

    Mining of an in-house collection of angiotensin II type 1 receptor antagonists to identify compounds with activity at the peroxisome proliferator-activated receptor-{gamma} (PPAR{gamma}) revealed a new series of imidazo[4,5-b]pyridines 2 possessing activity at these two receptors. Early availability of the crystal structure of the lead compound 2a bound to the ligand binding domain of human PPAR{gamma} confirmed the mode of interaction of this scaffold to the nuclear receptor and assisted in the optimization of PPAR{gamma} activity. Among the new compounds, (S)-3-(5-(2-(1H-tetrazol-5-yl)phenyl)-2,3-dihydro-1H-inden-1-yl)-2-ethyl-5-isobutyl-7-methyl-3H-imidazo[4,5-b]pyridine (2l) was identified as a potent angiotensin II type I receptor blocker (IC{sub 50} = 1.6 nM) with partial PPAR{gamma} agonism (EC{sub 50} = 212 nM, 31% max) and oral bioavailability in rat. The dual pharmacology of 2l was demonstrated in animal models of hypertension (SHR) and insulin resistance (ZDF rat). In the SHR, 2l was highly efficacious in lowering blood pressure, while robust lowering of glucose and triglycerides was observed in the male ZDF rat.

  13. Biohydrogen production using waste activated sludge disintegrated by gamma irradiation

    International Nuclear Information System (INIS)

    Yin, Yanan; Wang, Jianlong

    2015-01-01

    Highlights: • The waste activated sludge could be disintegrated by gamma irradiation. • The disintegrated sludge could be used for biohydrogen production. • Combined alkali-irradiation treatment achieved the highest solubilization of sludge. - Abstract: The biohydrogen production using the disintegrated and dissolved sludge by gamma irradiation was studied. The experimental results showed that gamma irradiation and irradiation combined with alkali pretreatment could disintegrate and dissolve waste activated sludge for biohydrogen production. The alkali-irradiation treatment of the sludge at pH = 12 and 20 kGy achieved the highest disintegration and dissolution, i.e., it could destroy the cell walls and release organic matters (such as soluble COD, polysaccharides and protein) into the solution. The disintegrated sludge could be used as a low-cost substrate for biohydrogen production

  14. Liquid scintillation counting techniques for the determination of some alpha emitting actinides: a review

    International Nuclear Information System (INIS)

    Mirashi, N.N.; Chander, Keshav; Aggarwal, S.K.

    2000-12-01

    The present report is a review of the work on liquid scintillation counting techniques, for the determination of alpha emitting actinides like uranium, plutonium, americium etc; for the last three decades (1970-1999). It covers the progress that has taken place in conventional liquid scintillation counting employing various solvents, scintillators and extractants. There is gradual development in instrumentation from integral counting of alpha emitters to alpha liquid scintillation spectrometry to resolve and identify different alpha emitters. These advancements have led to Pulse Shape Analysis (PSA) and Photon Electron Rejecting Alpha Liquid Scintillation Spectrometry (PERALS) techniques for the determination of the alpha emitters in the presence of beta and gamma activity. These techniques allow the determination of actinides at very low levels which has increased their applications to almost all the fields of chemistry; be it biomedical, environmental, geological or process chemistry of nuclear fuels. The development of biphasic technique using various extractants to separate different elements and counting in presence of one another has been made possible. Inorganic scintillators have been recently developed which have the advantage of eliminating effects of quenching and presence of beta/gamma emitting actinides. This review will serve as a reference to those who want to carry out work in the field of determination of actinides using liquid scintillation counting techniques. (author)

  15. Highly efficient exciplex organic light-emitting diodes incorporating a heptazine derivative as an electron acceptor.

    Science.gov (United States)

    Li, Jie; Nomura, Hiroko; Miyazaki, Hiroshi; Adachi, Chihaya

    2014-06-11

    Highly efficient exciplex systems incorporating a heptazine derivative () as an electron acceptor and 1,3-di(9H-carbazol-9-yl)benzene () as an electron donor are developed. An organic light-emitting diode containing 8 wt% : as an emitting layer exhibits a maximum external quantum efficiency of 11.3%.

  16. Vertical-cavity surface-emitting lasers for medical diagnosis

    DEFF Research Database (Denmark)

    Ansbæk, Thor

    This thesis deals with the design and fabrication of tunable Vertical-Cavity Surface-Emitting Lasers (VCSELs). The focus has been the application of tunable VCSELs in medical diagnostics, specifically OCT. VCSELs are candidates as light sources for swept-source OCT where their high sweep rate, wide...

  17. Gamma-spectrometric measurement of radioactivity in agricultural soils of the Lombardia region, northern Italy

    International Nuclear Information System (INIS)

    Guidotti, Laura; Carini, Franca; Rossi, Riccardo; Gatti, Marina; Cenci, Roberto M.; Beone, Gian Maria

    2015-01-01

    This work is part of a wider monitoring project of the agricultural soils in Lombardia, which aims to build a database of topsoil properties and the potentially toxic elements, organic pollutants and gamma emitting radionuclides that the topsoils contain. A total of 156 agricultural soils were sampled according to the LUCAS (Land Use/Cover Area frame statistical Survey) standard procedure. The aim was to provide a baseline to document the conditions present at the time of sampling. The results of the project concerning soil radioactivity are presented here. The aim was to assess the content of 238 U, 232 Th, 137 Cs and 40 K by measuring soil samples by gamma spectrometry. 238 U, 232 Th and 40 K activities range 24–231, 20–70, and 242–1434 Bq kg −1 respectively. The geographic distribution of 238 U reflects the geophysical framework of the Lombardia region: the soils with high content of uranium are distributed for the most part in the South Alpine belt, where the presence of magmatic rocks is widespread. These soils show an higher activity of 238 U than of 232 Th. The 238 U activities become lower than 232 Th when soils are located in the plain, originating from basic sedimentary rocks. 137 Cs activity ranges 0.4–86.8 kBq m −2 . The lowest activity of 137 Cs is in the plain, whereas the highest is in the North on soils kept as lawn or pasture. The 137 Cs activity of some samples suggests the presence of accumulation processes that lead to 137 Cs enriched soils. This is the first survey of gamma emitting radionuclides in Lombardia that is based on the LUCAS standard sampling. The results from this monitoring campaign are important for the human radiation exposure and provide the zero point, which will be useful for assessing future effects due to external factors such as human activities. - Highlights: • A monitoring campaign of agricultural soils was carried out in Lombardia, Italy. • 156 topsoils were sampled according to the European standard

  18. Use of gamma ray attenuation technique in the study on Pinus oocarpa specific mass variation of 24-years old

    International Nuclear Information System (INIS)

    Rezende, Marcos Antonio de; Guerrini, Ivan Amaral; Ducatti, Carlos

    1999-01-01

    The work studies the physical properties of the wood, evidencing the use of the 241 Am, as gamma radiation source. The results showed that most of the trees of Pinus oocarpa presented a pick of high specific mass in the beginning of the growth, followed by a decrease near by the 5 year-old age. Starting from that age, there was gradual increment of the specific mass to the cut age, made to the 24 years. (author)

  19. Activity measurement of phosphorus-32 in the presence of pure beta-emitting impurities

    CSIR Research Space (South Africa)

    Simpson, B

    2006-02-27

    Full Text Available Activity measurements undertaken at the CSIR's National Metrology Laboratory (NML) on a solution of the pure beta-emitting radionuclide phosphorus-32, which formed part of an international key comparison, are described. Since exploratory source...

  20. TLR2-dependent inhibition of macrophage responses to IFN-gamma is mediated by distinct, gene-specific mechanisms.

    Directory of Open Access Journals (Sweden)

    Sarah A Benson

    2009-07-01

    Full Text Available Mycobacterium tuberculosis uses multiple mechanisms to avoid elimination by the immune system. We have previously shown that M. tuberculosis can inhibit selected macrophage responses to IFN-gamma through TLR2-dependent and -independent mechanisms. To specifically address the role of TLR2 signaling in mediating this inhibition, we stimulated macrophages with the specific TLR2/1 ligand Pam(3CSK(4 and assayed responses to IFN-gamma. Pam(3CSK(4 stimulation prior to IFN-gamma inhibited transcription of the unrelated IFN-gamma-inducible genes, CIITA and CXCL11. Surface expression of MHC class II and secretion of CXCL11 were greatly reduced as well, indicating that the reduction in transcripts had downstream effects. Inhibition of both genes required new protein synthesis. Using chromatin immunoprecipitation, we found that TLR2 stimulation inhibited IFN-gamma-induced RNA polymerase II binding to the CIITA and CXCL11 promoters. Furthermore, TATA binding protein was unable to bind the TATA box of the CXCL11 promoter, suggesting that assembly of transcriptional machinery was disrupted. However, TLR2 stimulation affected chromatin modifications differently at each of the inhibited promoters. Histone H3 and H4 acetylation was reduced at the CIITA promoter but unaffected at the CXCL11 promoter. In addition, NF-kappaB signaling was required for inhibition of CXCL11 transcription, but not for inhibition of CIITA. Taken together, these results indicate that TLR2-dependent inhibition of IFN-gamma-induced gene expression is mediated by distinct, gene-specific mechanisms that disrupt binding of the transcriptional machinery to the promoters.

  1. Actively shielded low level gamma - spectrometric system

    International Nuclear Information System (INIS)

    Mrdja, D.; Bikit, I.; Forkapic, S.; Slivka, J.; Veskovic, M.

    2005-01-01

    The results of the adjusting and testing of the actively shielded low level gamma-spectrometry system are presented. The veto action of the shield reduces the background in the energy region of 50 keV to the 2800 keV for about 3 times. (author) [sr

  2. A rapid dissolution procedure to aid initial nuclear forensics investigations of chemically refractory compounds and particles prior to gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Reading, David G., E-mail: d.reading@noc.soton.ac.uk [GAU-Radioanalytical Laboratories, Ocean and Earth Science, University of Southampton, National Oceanography Centre, European Way, Southampton SO14 3ZH (United Kingdom); Croudace, Ian W.; Warwick, Phillip E. [GAU-Radioanalytical Laboratories, Ocean and Earth Science, University of Southampton, National Oceanography Centre, European Way, Southampton SO14 3ZH (United Kingdom); Britton, Richard [AWE plc, Aldermaston, Reading, Berkshire, RG7 4PR (United Kingdom)

    2015-11-05

    A rapid and effective preparative procedure has been evaluated for the accurate determination of low-energy (40–200 keV) gamma-emitting radionuclides ({sup 210}Pb, {sup 234}Th, {sup 226}Ra, {sup 235}U) in uranium ores and uranium ore concentrates (UOCs) using high-resolution gamma ray spectrometry. The measurement of low-energy gamma photons is complicated in heterogeneous samples containing high-density mineral phases and in such situations activity concentrations will be underestimated. This is because attenuation corrections, calculated based on sample mean density, do not properly correct where dense grains are dispersed within a less dense matrix (analogous to a nugget effect). The current method overcomes these problems using a lithium tetraborate fusion that readily dissolves all components including high-density, self-attenuating minerals/compounds. This is the ideal method for dissolving complex, non-volatile components in soils, rocks, mineral concentrates, and other materials where density reduction is required. Lithium borate fusion avoids the need for theoretical efficiency corrections or measurement of matrix matched calibration standards. The resulting homogeneous quenched glass produced can be quickly dissolved in nitric acid producing low-density solutions that can be counted by gamma spectrometry. The effectiveness of the technique is demonstrated using uranium-bearing Certified Reference Materials and provides accurate activity concentration determinations compared to the underestimated activity concentrations derived from direct measurements of a bulk sample. The procedure offers an effective solution for initial nuclear forensic studies where complex refractory minerals or matrices exist. It is also significantly faster, safer and simpler than alternative approaches. - Highlights: • Low energy gamma photons (<200 keV) are attenuated in U-bearing compounds. • Corrections based on bulk density do not yield accurate activity

  3. What's that sound? Matches with auditory long-term memory induce gamma activity in human EEG.

    Science.gov (United States)

    Lenz, Daniel; Schadow, Jeanette; Thaerig, Stefanie; Busch, Niko A; Herrmann, Christoph S

    2007-04-01

    In recent years the cognitive functions of human gamma-band activity (30-100 Hz) advanced continuously into scientific focus. Not only bottom-up driven influences on 40 Hz activity have been observed, but also top-down processes seem to modulate responses in this frequency band. Among the various functions that have been related to gamma activity a pivotal role has been assigned to memory processes. Visual experiments suggested that gamma activity is involved in matching visual input to memory representations. Based on these findings we hypothesized that such memory related modulations of gamma activity exist in the auditory modality, as well. Thus, we chose environmental sounds for which subjects already had a long-term memory (LTM) representation and compared them to unknown, but physically similar sounds. 21 subjects had to classify sounds as 'recognized' or 'unrecognized', while EEG was recorded. Our data show significantly stronger activity in the induced gamma-band for recognized sounds in the time window between 300 and 500 ms after stimulus onset with a central topography. The results suggest that induced gamma-band activity reflects the matches between sounds and their representations in auditory LTM.

  4. Mechanism of Action for Anti-radiation Vaccine in Reducing the Biological Impact of High-dose Gamma Irradiation

    Science.gov (United States)

    Maliev, Vladislav; Popov, Dmitri; Jones, Jeffrey A.; Casey, Rachael C.

    2007-01-01

    Ionizing radiation is a major health risk of long-term space travel, the biological consequences of which include genetic and oxidative damage. In this study, we propose an original mechanism by which high doses of ionizing radiation induce acute toxicity. We identified biological components that appear in the lymphatic vessels shortly after gamma irradiation. These radiation-induced toxins, which we have named specific radiation determinants (SRD), were generated in the irradiated tissues and then collected and circulated throughout the body via the lymph circulation and bloodstream. Depending on the type of SRD elicited, different syndromes of acute radiation sickness (ARS) were expressed. The SRDs were developed into a vaccine used to confer active immunity against acute radiation toxicity in immunologically naive animals. Animals that were pretreated with SRDs exhibited resistance to lethal doses of gamma radiation, as measured by increased survival times and survival rates. In comparison, untreated animals that were exposed to similar large doses of gamma radiation developed acute radiation sickness and died within days. This phenomenon was observed in a number of mammalian species. Initial analysis of the biochemical characteristics indicated that the SRDs were large molecular weight (200-250 kDa) molecules that were comprised of a mixture of protein, lipid, carbohydrate, and mineral. Further analysis is required to further identify the SRD molecules and the biological mechanism by which the mediate the toxicity associated with acute radiation sickness. By doing so, we may develop an effective specific immunoprophylaxis as a countermeasure against the acute effects of ionizing radiation.

  5. Implementation of the Prompt Gamma facility in the ININ; Implementacion de la instalacion del Prompt Gamma en el ININ

    Energy Technology Data Exchange (ETDEWEB)

    Macias B, L.R.; Delfin L, A.; Aguilar H, F. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The Prompt Gamma Neutron Activation Analysis (PGNAA) technique is based on the reaction of a neutron and an atom emitting gamma radiation in an immediate form and it is used for the elemental identification and characterization. This is a non-destructive technique and presents advantages compared with the X-ray fluorescence analysis technique since it has the advantage of the ability for the neutron penetration which allows a complete analysis in volume of material while the X-ray penetration is not very deep, it is superficial and other advantage of PGNAA is that can detects light elements while by mean of the X-ray fluorescence technique it is not possible. In this work it is shown the implementation of this technique un the National Institute of Nuclear Research (ININ) and the way in which this technique is applied with a radiation source of the TRIGA Mark III reactor from which thermal neutrons were isolated. (Author)

  6. Evaluation of {sup 211}At-labelled monodisperse polymer particles in vivo: comparison of different specific activities

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, R.H.; Hoff, Per; Alstad, Jorolf [Oslo Univ., Chemistry Dept., Oslo (Norway); Varaas, Tone; De Vos, L.N.; Nustad, Kjell [Norwegian Radium Hospital, Central Lab., Oslo (Norway); Vergote, I.B. [Norwegian Radium Hospital, Gynecologic Oncology Dept., Oslo (Norway)

    1996-09-01

    The {alpha}-particle emitter {sup 211}At was covalently coupled to 1.8 {mu}m aminated monodisperse polymer particles (MDPP) and used to irradiate the intraperitoneal cavity in mice with disseminated tumour cells. Specific activity has previously been shown to influence the therapeutic efficacy of {alpha}-particle emitting compounds and the therapeutic efficacy of {sup 211}At-MDPP with various specific activity was therefore investigated. Groups of mice (10 animals per group) were treated with intraperitoneal injections of 100 kBq of {sup 211}At-MDPP with specific activities of 0.19, 0.55, 1.7, 5.0, 15, and 45 MBq/mg. A significantly prolonged survival was observed in the treated groups compared to the control group (from 19 to 26 days vs. 12 days, median). The difference in survival between the {sup 211}At-MDPP treated groups was not significant, but some animals with short survival were observed in the groups that had received the 0.19, 15 and 45 MBq/mg preparations. K13 monoclonal antibody values, which are an indicator of tumour growth, were high in some animals in the 15 and 45 MBq/mg groups (day 7 values). (author).

  7. Effect of Gamma Irradiation on Antioxidant Activity and Curcuminoids of Curcuma longa L

    International Nuclear Information System (INIS)

    Thongphasuk, Piyanuch; Thongphasuk, Jarunee; Kulchanapakawat, Tiwat; Sajjabut, Surasak; Pongpat, Suchada; Eamsiri, Jaruratana

    2007-08-01

    Full text: Gamma irradiation at the dose of 10 kGy is one of the methods to reduce microbial contamination of medicinal herbs. Since irradiation may also affect active compounds of the herbs, the objective of this research was to study the effect of gamma irradiation (10 kGy) on antioxidant activity and curcuminoids contents of Curcuma longa L. DPPH (1,1-diphenyl-2-picryl-hydrazyl H) was used to study antioxidant activity and UV-spectrophotometry was used to study curcuminoids contents. The results showed that gamma irradiation at 10 kGy did not significantly affect antioxidant activity and curcuminoids contents of C. longa

  8. Respiratory activity variations induced in groups of LD 12:12 synchronized Sprague-Dawley rats by a 100 dB white noise emitted at 12-h intervals.

    Science.gov (United States)

    Stupfel, M; Molin, D; Thierry, H; Busnel, M C

    1980-01-01

    A white noise is emitted during 2 h, either in the middle of the scotoperiod (activity period) or of the photoperiod (rest period), on grouped specific pathogen free (SPF) male Sprague-Dawley rats, LD 12:12 synchronized by light (L = 6 h = 150 lux). Continuous measurements of VCO2, taken as an index of respiratory activity shows: 1. a short increase both after the beginning and the end of the stimulus, with slight time length differences between young and older rats; 2. a slight (2-3%) continued increase during the photoperiod and a high decrease (13%) during the scotoperiod. These VCO2 variations obtained during and after the white noise emission correspond to measurements of activity displacement and observations of behavior performed on a small sample of rats.

  9. Determination of low specific activity iodine-129 off-gas concentrations by GC separation and negative ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, S.J.; Rankin, R.A.; McManus, G.J.; Nielsen, R.A.; Delmore, J.E.; Hohorst, F.A.; Murphy, L.P.

    1983-09-01

    This document is the final report of the laboratory development of a method for determining the specific activity of the /sup 129/I emitted from a nuclear fuel reprocessing plant. The technique includes cryogenic sample collection, chemical form separation, quantitation by gas chromatography, and specific activity measurement of each chemical species by negative ionization mass spectrometry. The major conclusions were that both organic and elemental iodine can be quantitatively collected without fractionation and that specific activity measurements as low as one atom of /sup 129/I per 10/sup 5/ atoms of /sup 127/I are possible.

  10. High energy neutrinos from gamma-ray bursts with precursor supernovae.

    Science.gov (United States)

    Razzaque, Soebur; Mészáros, Peter; Waxman, Eli

    2003-06-20

    The high energy neutrino signature from proton-proton and photo-meson interactions in a supernova remnant shell ejected prior to a gamma-ray burst provides a test for the precursor supernova, or supranova, model of gamma-ray bursts. Protons in the supernova remnant shell and photons entrapped from a supernova explosion or a pulsar wind from a fast-rotating neutron star remnant provide ample targets for protons escaping the internal shocks of the gamma-ray burst to interact and produce high energy neutrinos. We calculate the expected neutrino fluxes, which can be detected by current and future experiments.

  11. Manufacturing polymer light emitting diode with high luminance efficiency by solution process

    Science.gov (United States)

    Kim, Miyoung; Jo, SongJin; Yang, Ho Chang; Yoon, Dang Mo; Kwon, Jae-Taek; Lee, Seung-Hyun; Choi, Ju Hwan; Lee, Bum-Joo; Shin, Jin-Koog

    2012-06-01

    While investigating polymer light emitting diodes (polymer-LEDs) fabricated by solution process, surface roughness influences electro-optical (E-O) characteristics. We expect that E-O characteristics such as luminance and power efficiency related to surface roughness and layer thickness of emitting layer with poly-9-Vinylcarbazole. In this study, we fabricated polymer organic light emitting diodes by solution process which guarantees easy, eco-friendly and low cost manufacturing for flexible display applications. In order to obtain high luminescence efficiency, E-O characteristics of these devices by varying parameters for printing process have been investigated. Therefore, we optimized process condition for polymer-LEDs by adjusting annealing temperatures of emission, thickness of emission layer showing efficiency (10.8 cd/A) at 10 mA/cm2. We also checked wavelength dependent electroluminescence spectrum in order to find the correlation between the variation of efficiency and the thickness of the layer.

  12. Highly Efficient Spectrally Stable Red Perovskite Light-Emitting Diodes.

    Science.gov (United States)

    Tian, Yu; Zhou, Chenkun; Worku, Michael; Wang, Xi; Ling, Yichuan; Gao, Hanwei; Zhou, Yan; Miao, Yu; Guan, Jingjiao; Ma, Biwu

    2018-05-01

    Perovskite light-emitting diodes (LEDs) have recently attracted great research interest for their narrow emissions and solution processability. Remarkable progress has been achieved in green perovskite LEDs in recent years, but not blue or red ones. Here, highly efficient and spectrally stable red perovskite LEDs with quasi-2D perovskite/poly(ethylene oxide) (PEO) composite thin films as the light-emitting layer are reported. By controlling the molar ratios of organic salt (benzylammonium iodide) to inorganic salts (cesium iodide and lead iodide), luminescent quasi-2D perovskite thin films are obtained with tunable emission colors from red to deep red. The perovskite/polymer composite approach enables quasi-2D perovskite/PEO composite thin films to possess much higher photoluminescence quantum efficiencies and smoothness than their neat quasi-2D perovskite counterparts. Electrically driven LEDs with emissions peaked at 638, 664, 680, and 690 nm have been fabricated to exhibit high brightness and external quantum efficiencies (EQEs). For instance, the perovskite LED with an emission peaked at 680 nm exhibits a brightness of 1392 cd m -2 and an EQE of 6.23%. Moreover, exceptional electroluminescence spectral stability under continuous device operation has been achieved for these red perovskite LEDs. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Measurement systems in the area of land remediation and soil segregation activities

    International Nuclear Information System (INIS)

    Simon, Gerold G.; Sokcic-Kostic, Marina; Auler, Ingolf; Eickelpasch, Ludger; Betts, Jonathan

    2007-01-01

    Available in abstract form only. Full text of publication follows: The remediation of radioactively contaminated land is a small but growing sector in the area of decommissioning of nuclear facilities. This also includes the material from buildings after demolition. Contamination comprises in general alpha and beta activities and emission of alpha, beta and gamma radiation. The measurement is in practice restricted to the measurement of gamma emission, because of the high penetration of material by gamma rays. All isotopes, which do not emit gammas are estimated on the basis of given relation between alpha and beta emitters without gamma radiation and emitters with gamma radiation. This method is called 'key nuclide method'. Whilst many studies have been completed, others still continue in the processing of large volumes of concrete, steel and soil. An important conclusion from these and similar research programs is that a significant proportion of the waste contains only low concentrations of radioactive nuclides. Therefore, much of the material from the remediation can be considered for 'free release'. It was often not possible to attain adequate specific information on these materials, so a measurement system is needed for their classification and characterization. NUKEM Technologies has practical experience in characterising and remediating of nuclear sites. Recently, it has pioneered the use of innovative in-situ and ex-situ characterisation and waste segregation technologies, which enhance the efficiency of remedial actions and provide assurance to customers, regulators and the public that all significant contamination has been removed and sites can be used for new purposes. (authors)

  14. Color-tunable and high-efficiency organic light-emitting diode by adjusting exciton bilateral migration zone

    Science.gov (United States)

    Liu, Shengqiang; Wu, Ruofan; Huang, Jiang; Yu, Junsheng

    2013-09-01

    A voltage-controlled color-tunable and high-efficiency organic light-emitting diode (OLED) by inserting 16-nm N,N'-dicarbazolyl-3,5-benzene (mCP) interlayer between two complementary emitting layers (EMLs) was fabricated. The OLED emitted multicolor ranging from blue (77.4 cd/A @ 6 V), white (70.4 cd/A @ 7 V), to yellow (33.7 cd/A @ 9 V) with voltage variation. An equivalent model was proposed to reveal the color-tunable and high-efficiency emission of OLEDs, resulting from the swing of exciton bilateral migration zone near mCP/blue-EML interface. Also, the model was verified with a theoretical arithmetic using single-EML OLEDs to disclose the crucial role of mCP exciton adjusting layer.

  15. Top emitting white OLEDs

    Energy Technology Data Exchange (ETDEWEB)

    Freitag, Patricia; Luessem, Bjoern; Leo, Karl [Technische Universitaet Dresden, Institut fuer Angewandte Photophysik, George-Baehr-Strasse 1, 01069 Dresden (Germany)

    2009-07-01

    Top emitting organic light emitting diodes (TOLEDs) provide a number of interesting opportunities for new applications, such as the opportunity to fabricate ITO-free devices by using opaque substrates. This makes it possible to manufacture low cost OLEDs for signage and lighting applications. A general top emitting device consists of highly reflecting metal contacts as anode and semitransparent cathode, the latter one for better outcouling reasons. In between several organic materials are deposited as charge transporting, blocking, and emission layers. Here, we show a top emitting white organic light emitting diode with silver electrodes arranged in a p-i-n structure with p- and n-doped charge transport layers. The centrical emission layer consists of two phosphorescent (red and green) and one fluorescent (blue) emitter systems separated by an ambipolar interlayer to avoid mutual exciton quenching. By adding an additional dielectric capping layer on top of the device stack, we achieve a reduction of the strong microcavity effects which appear due to the high reflection of both metal electrodes. Therefore, the outcoupled light shows broad and nearly angle-independent emission spectra, which is essential for white light emitting diodes.

  16. Gamma beams generation with high intensity lasers for two photon Breit-Wheeler pair production

    Science.gov (United States)

    D'Humieres, Emmanuel; Ribeyre, Xavier; Jansen, Oliver; Esnault, Leo; Jequier, Sophie; Dubois, Jean-Luc; Hulin, Sebastien; Tikhonchuk, Vladimir; Arefiev, Alex; Toncian, Toma; Sentoku, Yasuhiko

    2017-10-01

    Linear Breit-Wheeler pair creation is the lowest threshold process in photon-photon interaction, controlling the energy release in Gamma Ray Bursts and Active Galactic Nuclei, but it has never been directly observed in the laboratory. Using numerical simulations, we demonstrate the possibility to produce collimated gamma beams with high energy conversion efficiency using high intensity lasers and innovative targets. When two of these beams collide at particular angles, our analytical calculations demonstrate a beaming effect easing the detection of the pairs in the laboratory. This effect has been confirmed in photon collision simulations using a recently developed innovative algorithm. An alternative scheme using Bremsstrahlung radiation produced by next generation high repetition rate laser systems is also being explored and the results of first optimization campaigns in this regime will be presented.

  17. Prehistory analysis using photon activation analysis

    International Nuclear Information System (INIS)

    Krausova, I.; Chvatil, D.; Tajer, J.

    2017-01-01

    Instrumental photon activation analysis (IPAA) is a suitable radio-analytical method for non-destructive determination of total nitrogen in various matrices. IPAA determination of nitrogen is based on 14 N (γ, n) 13 N nuclear reaction after high-energy photon irradiation. The analytically usable product of this photo-nuclear reaction is a positron emitter emitting only non-specific annihilation of 511 keV, which can be emitted by other radionuclides present in the sample. Some of them, besides the non-specific 511 keV line, also emit specific lines that allow their contribution to analytical radionuclide 13 N to be subtracted. An efficient source of high-energy photon radiation is the secondary bremsstrahlung generated by the conversion of the electron beam accelerated by a high-frequency circular accelerator - a microtron. The non-destructive IPAA contributed to the clarification of the origins of a precious bracelet originating from a fortified settlement in the area of Karlovy Vary - Drahovice from the late Bronze Age. (authors)

  18. A system of radiation monitoring, and methods and equipment for measuring water of low specific activity

    International Nuclear Information System (INIS)

    Sivintsev, Yu.V.

    1975-01-01

    The author considers criteria for the radiation protection of the population and the environment. He describes the role of procedures for monitoring waters of low specific activity in the framework of a system for ensuring the radiation safety of the population living near a nuclear power station. The main technical characteristics (background, efficiency, sensitivity) of the laboratory equipment for gamma spectrometric analysis of water samples of low specific activity are discussed. (author)

  19. Waste inspection tomography (WIT)

    Energy Technology Data Exchange (ETDEWEB)

    Bernardi, R.T. [Bio-Imaging Research, Inc., Lincolnshire, IL (United States)

    1995-10-01

    Waste Inspection Tomography (WIT) provides mobile semi-trailer mounted nondestructive examination (NDE) and assay (NDA) for nuclear waste drum characterization. WIT uses various computed tomography (CT) methods for both NDE and NDA of nuclear waste drums. Low level waste (LLW), transuranic (TRU), and mixed radioactive waste can be inspected and characterized without opening the drums. With externally transmitted x-ray NDE techniques, WIT has the ability to identify high density waste materials like heavy metals, define drum contents in two- and three-dimensional space, quantify free liquid volumes through density and x-ray attenuation coefficient discrimination, and measure drum wall thickness. With waste emitting gamma-ray NDA techniques, WIT can locate gamma emitting radioactive sources in two- and three-dimensional space, identify gamma emitting, isotopic species, identify the external activity levels of emitting gamma-ray sources, correct for waste matrix attenuation, provide internal activity approximations, and provide the data needed for waste classification as LLW or TRU.

  20. Waste inspection tomography (WIT)

    International Nuclear Information System (INIS)

    Bernardi, R.T.

    1995-01-01

    Waste Inspection Tomography (WIT) provides mobile semi-trailer mounted nondestructive examination (NDE) and assay (NDA) for nuclear waste drum characterization. WIT uses various computed tomography (CT) methods for both NDE and NDA of nuclear waste drums. Low level waste (LLW), transuranic (TRU), and mixed radioactive waste can be inspected and characterized without opening the drums. With externally transmitted x-ray NDE techniques, WIT has the ability to identify high density waste materials like heavy metals, define drum contents in two- and three-dimensional space, quantify free liquid volumes through density and x-ray attenuation coefficient discrimination, and measure drum wall thickness. With waste emitting gamma-ray NDA techniques, WIT can locate gamma emitting radioactive sources in two- and three-dimensional space, identify gamma emitting, isotopic species, identify the external activity levels of emitting gamma-ray sources, correct for waste matrix attenuation, provide internal activity approximations, and provide the data needed for waste classification as LLW or TRU