  1. Cardiac troponins--Translational biomarkers in cardiology: Theory and practice of cardiac troponin high-sensitivity assays.

    Science.gov (United States)

    Adamcova, Michaela; Popelova-Lencova, Olga; Jirkovsky, Eduard; Simko, Fedor; Gersl, Vladimir; Sterba, Martin

    2016-01-01

    Tn is a unique translational biomarker in cardiology whose potential has not been diminished in the new era of high sensitive assays. cTns can be valuable markers in cardiac diseases as well as in infectious diseases and respiratory diseases. Furthermore, the role of cTns is growing in the routine evaluation of cardioxicity and in determining the efficacy/safety ratio of novel cardioprotective strategies in clinical settings. cTns can detect myocardial injury not only in a wide spectrum of laboratory animals in experimental studies in vivo, but also in isolated heart models or cardiomyocytes in vitro. The crucial issue regarding the cross-species usage of cardiac troponin investigation remains the choice of cardiac troponin testing. This review summarizes the recent proteomic data on aminoacid sequences of cTnT and cTnI in various species, as well as selected analytical characteristics of human cardiac troponin high-sensitivity assays. Due to the highly phylogenetically conserved structure of troponins, the same bioindicator can be investigated using the same method in both clinical and experimental cardiology, thus contributing to a better understanding of the pathogenesis of cardiac diseases as well as to increased effectiveness of troponin use in clinical practice. Measuring cardiac troponins using commercially available human high-sensitivity cardiac troponin tests with convenient antibodies selected on the basis of adequate proteomic knowledge can solve many issues which would otherwise be difficult to address in clinical settings for various ethical and practical reasons. Our survey could help elaborate the practical guidelines for optimizing the choice of cTns assay in cardiology. © 2016 International Union of Biochemistry and Molecular Biology.

  2. High sensitivity troponin and valvular heart disease.

    Science.gov (United States)

    McCarthy, Cian P; Donnellan, Eoin; Phelan, Dermot; Griffin, Brian P; Enriquez-Sarano, Maurice; McEvoy, John W

    2017-07-01

    Blood-based biomarkers have been extensively studied in a range of cardiovascular diseases and have established utility in routine clinical care, most notably in the diagnosis of acute coronary syndrome (e.g., troponin) and the management of heart failure (e.g., brain-natriuretic peptide). The role of biomarkers is less well established in the management of valvular heart disease (VHD), in which the optimal timing of surgical intervention is often challenging. One promising biomarker that has been the subject of a number of recent VHD research studies is high sensitivity troponin (hs-cTn). Novel high-sensitivity assays can detect subclinical myocardial damage in asymptomatic individuals. Thus, hs-cTn may have utility in the assessment of asymptomatic patients with severe VHD who do not have a clear traditional indication for surgical intervention. In this state-of-the-art review, we examine the current evidence for hs-cTn as a potential biomarker in the most commonly encountered VHD conditions, aortic stenosis and mitral regurgitation. This review provides a synopsis of early evidence indicating that hs-cTn has promise as a biomarker in VHD. However, the impact of its measurement on clinical practice and VHD outcomes needs to be further assessed in prospective studies before routine clinical use becomes a reality. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay.

    Science.gov (United States)

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian

    2017-08-01

    High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research high-sensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time-resolved detection of lanthanide fluorescence based on the time constants of the system and analyze the background and noise sources in a heterogeneous fluoroimmunoassay. We determine the limiting factors and their impact on the measurement performance. The suggested model can be generally applied to fluoroimmunoassays employing the dry-cup concept.

  4. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay

    DEFF Research Database (Denmark)

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter

    2017-01-01

    of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared...... to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research highsensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time...

  5. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay

    OpenAIRE

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian

    2017-01-01

    High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by fac...

  6. Transitioning high sensitivity cardiac troponin I (hs-cTnI) into routine diagnostic use: More than just a sensitivity issue

    LENUS (Irish Health Repository)

    Lee, Graham R

    2016-04-01

    High sensitivity cardiac troponin T and I (hs-cTnT and hs-cTnI) assays show analytical, diagnostic and prognostic improvement over contemporary sensitive cTn assays. However, given the importance of troponin in the diagnosis of myocardial infarction, implementing this test requires rigorous analytical and clinical verification across the total testing pathway. This was the aim of this study.

  7. Immediate rule-out of acute myocardial infarction using electrocardiogram and baseline high-sensitivity troponin I

    DEFF Research Database (Denmark)

    Neumann, Johannes Tobias; Sörensen, Nils Arne; Ojeda, Francisco

    2017-01-01

    AIMS: Serial measurements of high-sensitivity troponin are used to rule out acute myocardial infarction (AMI) with an assay specific cutoff at the 99th percentile. Here, we evaluated the performance of a single admission troponin with a lower cutoff combined with a low risk electrocardiogram (ECG...

  8. High-sensitivity cardiac troponin I and risk of heart failure in patients with suspected acute coronary syndrome: a cohort study.

    Science.gov (United States)

    Stelzle, Dominik; Shah, Anoop S V; Anand, Atul; Strachan, Fiona E; Chapman, Andrew R; Denvir, Martin A; Mills, Nicholas L; McAllister, David A

    2018-01-01

    Heart failure may occur following acute myocardial infarction, but with the use of high-sensitivity cardiac troponin assays we increasingly diagnose patients with minor myocardial injury. Whether troponin concentrations remain a useful predictor of heart failure in patients with acute coronary syndrome is uncertain. We identified all consecutive patients (n = 4748) with suspected acute coronary syndrome (61 ± 16 years, 57% male) presenting to three secondary and tertiary care hospitals. Cox-regression models were used to evaluate the association between high-sensitivity cardiac troponin I concentration and subsequent heart failure hospitalization. C-statistics were estimated to evaluate the predictive value of troponin for heart failure hospitalization. Over 2071 years of follow-up there were 83 heart failure hospitalizations. Patients with troponin concentrations above the upper reference limit (URL) were more likely to be hospitalized with heart failure than patients below the URL (118/1000 vs. 17/1000 person years, adjusted hazard ratio: 7.0). Among patients with troponin concentrations acute coronary syndrome. The strongest associations were observed in patients with troponin concentrations in the normal reference range, in whom high-sensitivity cardiac troponin assays identify those at increased risk of heart failure who may benefit from further investigation and treatment. © The Author 2017. Published on behalf of the European Society of Cardiology

  9. Prognostic Value of High-Sensitivity Cardiac Troponin T Compared with Risk Scores in Stable Cardiovascular Disease.

    Science.gov (United States)

    Biener, Moritz; Giannitsis, Evangelos; Kuhner, Manuel; Zelniker, Thomas; Mueller-Hennessen, Matthias; Vafaie, Mehrshad; Trenk, Dietmar; Neumann, Franz-Josef; Hochholzer, Willibald; Katus, Hugo A

    2017-05-01

    Risk stratification of patients with cardiovascular disease remains challenging despite consideration of risk scores. We aimed to evaluate the prognostic performance of high-sensitivity cardiac troponin T in a low-risk outpatient population presenting for nonsecondary and secondary prevention. All-cause mortality, a composite of all-cause mortality, acute myocardial infarction, and stroke (end point 2), and a composite of all-cause mortality, acute myocardial infarction, stroke and rehospitalization for acute coronary syndrome, and decompensated heart failure (end point 3) were defined. The prognostic performance of high-sensitivity cardiac troponin T on index visit was compared with the PROCAM score and 3 FRAMINGHAM subscores. In 693 patients with a median follow-up of 796 days, we observed 16 deaths, 32 patients with end point 2, and 83 patients with end point 3. All risk scores performed better in the prediction of all-cause mortality in nonsecondary prevention (area under the curve [AUC]: PROCAM: 0.922 vs 0.523, P = .001, consistent for all other scores). In secondary prevention, high-sensitivity cardiac troponin T outperformed all risk scores in the prediction of all-cause mortality (ΔAUC: PROCAM: 0.319, P risk scores. Our findings on the prediction of all-cause mortality compared with the FRAMINGHAM-Hard Coronary Heart Disease score were confirmed in an independent validation cohort on 2046 patients. High-sensitivity troponin T provides excellent risk stratification regarding all-cause mortality and all-cause mortality, acute myocardial infarction, and stroke in a secondary prevention cohort in whom risk scores perform poorly. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Self-reported cocaine use is not associated with elevations in high-sensitivity troponin I.

    Science.gov (United States)

    Jordan, Candice D; Korley, Frederick K; Stolbach, Andrew I

    2017-06-01

    High-sensitivity troponin (hsTn) assays detect 10 times lower concentrations of cardiac troponin than conventional assays. We examined the effects of self-reported cocaine use to determine whether those with acute cocaine use being evaluated for ACS are more likely to have elevated hsTnI than those nonusers being evaluated for ACS. We conducted a sub-analysis of a prospective cohort of ED patients evaluated for acute coronary syndrome. Recent cocaine use was determined by structured patient interviews. High-sensitivity troponin (Abbott) and conventional troponin I (Abbott, cTnI) were measured on samples drawn at presentation. Urine toxicology screen for cocaine metabolite was obtained at the discretion of treating clinicians. Of 1862 patients enrolled, 444 reported prior cocaine use and 99 reported cocaine use within the preceding month. Median hsTn in patients with last cocaine use within 24 h, 2-7 days, 1 week-1 month, >1 month, and no prior cocaine use were: 9 (IQR: 3-17) ng/L, 6 (IQR: 3-24.3) ng/L, 6 (IQR: 3-89.5) ng/L, 3 (IQR: 3-18.5) ng/L and 3 (IQR: 3-17) ng/L, respectively. Urine toxicology assays (UTox) for cocaine were performed in 640 (34.4%) patients. The median hsTn for those who were UTox+, UTox - and those without a UTox were: 9 ng/L (IQR: 3-48.5), 9 ng/L (IQR: 3-40) and 3 ng/L (IQR: 3-12), respectively. There were no differences in the prevalence of new troponin elevations (hsTn >99th percentile but cTnI cocaine use compared to those without recent cocaine use. In this first investigation of hsTn in patients with self-reported recent cocaine use, we have determined that hsTn does not lead to an increase in the prevalence of troponin elevation in cocaine users.

  11. Rapid Rule-Out of Acute Myocardial Injury Using a Single High-Sensitivity Cardiac Troponin I Measurement.

    Science.gov (United States)

    Sandoval, Yader; Smith, Stephen W; Shah, Anoop S V; Anand, Atul; Chapman, Andrew R; Love, Sara A; Schulz, Karen; Cao, Jing; Mills, Nicholas L; Apple, Fred S

    2017-01-01

    Rapid rule-out strategies using high-sensitivity cardiac troponin assays are largely supported by studies performed outside the US in selected cohorts of patients with chest pain that are atypical of US practice, and focused exclusively on ruling out acute myocardial infarction (AMI), rather than acute myocardial injury, which is more common and associated with a poor prognosis. Prospective, observational study of consecutive patients presenting to emergency departments [derivation (n = 1647) and validation (n = 2198) cohorts], where high-sensitivity cardiac troponin I (hs-cTnI) was measured on clinical indication. The negative predictive value (NPV) and diagnostic sensitivity of an hs-cTnI concentration rules out acute myocardial injury, regardless of etiology, with an excellent NPV and diagnostic sensitivity, and identifies patients at minimal risk of AMI or cardiac death at 30 days. ClinicalTrials.gov Identifier: NCT02060760. © 2016 American Association for Clinical Chemistry.

  12. Measuring high-sensitivity cardiac troponin T blood concentration in population surveys.

    OpenAIRE

    Lazzarino, AI; Mindell, JS

    2017-01-01

    Introduction The blood test for high-sensitivity cardiac troponin T (HS-CTnT) has been proposed as a marker of cardiovascular risk in the general population, as it is associated with subsequent incidence of cardiovascular events and mortality. We aimed at evaluating the feasibility of HS-CTnT testing within large nationally-representative population surveys in which blood samples are collected during household visits, shipped using the standard civil postal service, and then frozen for subseq...

  13. Measuring high-sensitivity cardiac troponin T blood concentration in population surveys

    OpenAIRE

    Lazzarino, A. I.; Mindell, J. S.

    2017-01-01

    INTRODUCTION: The blood test for high-sensitivity cardiac troponin T (HS-CTnT) has been proposed as a marker of cardiovascular risk in the general population, as it is associated with subsequent incidence of cardiovascular events and mortality. We aimed at evaluating the feasibility of HS-CTnT testing within large nationally-representative population surveys in which blood samples are collected during household visits, shipped using the standard civil postal service, and then frozen for subse...

  14. High sensitivity cardiac troponin I detection in physiological environment using AlGaN/GaN High Electron Mobility Transistor (HEMT) Biosensors.

    Science.gov (United States)

    Sarangadharan, Indu; Regmi, Abiral; Chen, Yen-Wen; Hsu, Chen-Pin; Chen, Pei-Chi; Chang, Wen-Hsin; Lee, Geng-Yen; Chyi, Jen-Inn; Shiesh, Shu-Chu; Lee, Gwo-Bin; Wang, Yu-Lin

    2018-02-15

    In this study, we report the development of a high sensitivity assay for the detection of cardiac troponin I using electrical double layer gated high field AlGaN/GaN HEMT biosensor. The unique gating mechanism overcomes the drawback of charge screening seen in traditional FET based biosensors, allowing detection of target proteins in physiological solutions without sample processing steps. Troponin I specific antibody and aptamer are used as receptors. The tests carried out using purified protein solution and clinical serum samples depict high sensitivity, specificity and wide dynamic range (0.006-148ng/mL). No additional wash or sample pre-treatment steps are required, which greatly simplifies the biosensor system. The miniaturized HEMT chip is packaged in a polymer substrate and easily integrated with a portable measurement unit, to carry out quantitative troponin I detection in serum samples with < 2µl sample volume in 5min. The integrated prototype biosensor unit demonstrates the potential of the method as a rapid, inexpensive, high sensitivity CVD biomarker assay. The highly simplified protocols and enhanced sensor performance make our biosensor an ideal choice for point of care diagnostics and personal healthcare systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. High-sensitivity Cardiac Troponin Elevation after Electroconvulsive Therapy (ECT)

    Science.gov (United States)

    Duma, Andreas; Pal, Swatilika; Johnston, Joshua; Helwani, Mohammad A.; Bhat, Adithya; Gill, Bali; Rosenkvist, Jessica; Cartmill, Christopher; Brown, Frank; Miller, J. Philip; Scott, Mitchell G; Sanchez-Conde, Francisco; Jarvis, Michael; Farber, Nuri B.; Zorumski, Charles F.; Conway, Charles; Nagele, Peter

    2017-01-01

    Background While electroconvulsive therapy (ECT) is widely regarded as a life-saving and safe procedure, evidence regarding its effects on myocardial cell injury are sparse. The objective of this investigation was to determine incidence and magnitude of new cardiac troponin elevation after ECT using a novel high-sensitivity cardiac troponin I (hscTnI) assay. Methods This was a prospective cohort study in adult patients undergoing ECT in a single academic center (up to three ECT treatments per patient). The primary outcome was new hscTnI elevation after ECT, defined as an increase of hscTnI >100% after ECT compared to baseline with at least one value above the limit of quantification (10 ng/L). 12-lead ECG and hscTnI values were obtained prior to and 15–30 minutes after ECT; in a subset of patients an additional 2-hour hscTnI value was obtained. Results The final study population was 100 patients and a total of 245 ECT treatment sessions. Eight patients (8/100, 8%) experienced new hscTnI elevation after ECT with a cumulative incidence of 3.7% (9/245 treatments; one patient had two hscTnI elevations), two of whom had a non-ST-elevation myocardial infarction (incidence 2/245, 0.8%). Median hscTnI concentrations did not increase significantly after ECT. Tachycardia and/or elevated systolic blood pressure developed after approximately two thirds of ECT treatments. Conclusions ECT appears safe from a cardiac standpoint in a large majority of patients. A small subset of patients with pre-existing cardiovascular risk factors, however, may develop new cardiac troponin elevation after ECT, the clinical relevance of which is unclear in the absence of signs of myocardial ischemia. PMID:28166110

  16. European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay.

    Science.gov (United States)

    Krintus, Magdalena; Kozinski, Marek; Boudry, Pascal; Capell, Nuria Estañ; Köller, Ursula; Lackner, Karl; Lefèvre, Guillaume; Lennartz, Lieselotte; Lotz, Johannes; Herranz, Antonio Mora; Nybo, Mads; Plebani, Mario; Sandberg, Maria B; Schratzberger, Wolfgang; Shih, Jessie; Skadberg, Øyvind; Chargui, Ahmed Taoufik; Zaninotto, Martina; Sypniewska, Grazyna

    2014-11-01

    International recommendations highlight the superior value of cardiac troponins (cTns) for early diagnosis of myocardial infarction along with analytical requirements of improved precision and detectability. In this multicenter study, we investigated the analytical performance of a new high sensitive cardiac troponin I (hs-cTnI) assay and its 99th percentile upper reference limit (URL). Laboratories from nine European countries evaluated the ARCHITECT STAT high sensitive troponin I (hs-TnI) immunoassay on the ARCHITECT i2000SR/i1000SR immunoanalyzers. Imprecision, limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ) linearity of dilution, interferences, sample type, method comparisons, and 99th percentile URLs were evaluated in this study. Total imprecision of 3.3%-8.9%, 2.0%-3.5% and 1.5%-5.2% was determined for the low, medium and high controls, respectively. The lowest cTnI concentration corresponding to a total CV of 10% was 5.6 ng/L. Common interferences, sample dilution and carryover did not affect the hs-cTnI results. Slight, but statistically significant, differences with sample type were found. Concordance between the investigated hs-cTnI assay and contemporary cTnI assay at 99th percentile cut-off was found to be 95%. TnI was detectable in 75% and 57% of the apparently healthy population using the lower (1.1 ng/L) and upper (1.9 ng/L) limit of the LoD range provided by the ARCHITECT STAT hs-TnI package insert, respectively. The 99th percentile values were gender dependent. The new ARCHITECT STAT hs-TnI assay with improved analytical features meets the criteria of high sensitive Tn test and will be a valuable diagnostic tool.

  17. Diagnostic Utility of High Sensitivity Troponins for Echocardiographic Markers of Structural Heart Disease.

    Science.gov (United States)

    Wang, Tom Kai Ming; Dugo, Clementina; Gillian, Yvonne; Yvonne, Wynne; Heather, Semple; Kevin, Smith; Peter, Cleave; Jonathan, Christiansen; Andrew, To; Nezar, Amir; Scott, Tony; Ross, Boswell; Patrick, Gladding

    2018-02-15

    The conventional use of high-sensitivity troponins (hs-troponins) is for diagnosing myocardial infarction however they also have a role in chronic disease management. This pilot study assessed the relationship of hs-troponins with echocardiographic markers of left ventricular hypertrophy (LVH) and structural heart disease (SHD). Patients undergoing computer gomography (CT) coronary angiogram for low-intermediate risk chest pain and healthy volunteers were recruited. Hs-troponins Singulex I, Abbott I and Roche T and N-terminal pro-brain natriuretic peptide (NT-proBNP) were evaluated in relation to SHD parameters including left ventricular hypertrophy (LVH Echo ) and left atrial enlargement (LAE Echo ) on echocardiography. 78 subjects who underwent echocardiography were included in this study. C-statistics (95% confidence interval) of the four biomarkers for predicting LVH Echo were 0.84 (0.72-0.92), 0.84 (0.73-0.92), 0.75 (0.63-0.85) and 0.62 (0.49-0.74); for LAE Echo 0.74 (0.6-0.85), 0.78 (0.66-0.88), 0.55 (0.42-0.67) and 0.68 (0.62-0.85); and composite SHD 0.79 (0.66-0.88), 0.87 (0.75-0.94), 0.62 (0.49-0.73) and 0.74 (0.62-0.84) respectively. Optimal cut points for SHD were >1.2 ng/L, >1.6 ng/L, >8 ng/L and >18 pmol/L respectively. These results advocate the potential role of hs-troponins as screening tools for structural heart disease with theranostic implications.

  18. Association between high-sensitive troponin I and coronary artery calcification in a Danish general population

    DEFF Research Database (Denmark)

    Olson, Fredrik; Engborg, Jonathan; Grønhøj, Mette H.

    2016-01-01

    BACKGROUND: High-sensitive troponin I (hs-TnI) is an individual predictor of future cardiovascular disease (CVD). However, the relationship between hs-TnI and coronary artery calcification (CAC) as determined by computed tomography (CT) has not previously been investigated in a general population...

  19. Peri-operative troponin monitoring using a prototype high-sensitivity cardiac troponin I (hs-cTnI) assay: comparisons with hs-cTnT and contemporary cTnI assays.

    LENUS (Irish Health Repository)

    Lee, Graham R

    2013-09-18

    Non-cardiac surgery is associated with major vascular complications and higher incidences of elevated plasma troponin (cTn) concentration. Goal-directed therapy (GDT) is a stroke volume (SV)-guided approach to intravenous (IV) fluid therapy that improves tissue perfusion, oxygenation and reduces post-operative complications. In patients undergoing major gastro-intestinal surgery, we compared high sensitive and contemporary troponin assays and correlated results with patient outcome.

  20. Factors affecting high-sensitivity cardiac troponin T elevation in Japanese metabolic syndrome patients

    Directory of Open Access Journals (Sweden)

    Hitsumoto T

    2015-03-01

    Full Text Available Takashi Hitsumoto,1 Kohji Shirai2 1Hitsumoto Medical Clinic, Yamaguchi, Japan; 2Department of Vascular Function (donated, Sakura Hospital, Toho University School of Medicine, Chiba, Japan Purpose: The blood concentration of cardiac troponin T (ie, high-sensitivity cardiac troponin T [hs-cTnT], measured using a highly sensitive assay, represents a useful biomarker for evaluating the pathogenesis of heart failure or predicting cardiovascular events. However, little is known about the clinical significance of hs-cTnT in metabolic syndrome. The aim of this study was to examine the factors affecting hs-cTnT elevation in Japanese metabolic syndrome patients. Patients and methods: We enrolled 258 metabolic syndrome patients who were middle-aged males without a history of cardiovascular events. We examined relationships between hs-cTnT and various clinical parameters, including diagnostic parameters of metabolic syndrome. Results: There were no significant correlations between hs-cTnT and diagnostic parameters of metabolic syndrome. However, hs-cTnT was significantly correlated with age (P<0.01, blood concentrations of brain natriuretic peptide (P<0.01, reactive oxygen metabolites (markers of oxidative stress, P<0.001, and the cardio–ankle vascular index (marker of arterial function, P<0.01. Furthermore, multiple regression analysis revealed that these factors were independent variables for hs-cTnT as a subordinate factor. Conclusion: The findings of this study indicate that in vivo oxidative stress and abnormality of arterial function are closely associated with an increase in hs-cTnT concentrations in Japanese metabolic syndrome patients. Keywords: troponin, metabolic syndrome, risk factor, oxidative stress, cardio–ankle vascular index

  1. Cardiaal troponine

    NARCIS (Netherlands)

    Mingels, A.M.; Gorgels, T.P.; van Dieijen-Visser, M.P.

    2012-01-01

    Measurement of cardiac troponins (cTnT and cTnI), the only cardiac specific biomarkers available, is the gold standard in diagnosing acute coronary syndrome. Due to the recent introduction of more sensitive methods i.e. the high-sensitivity troponin assays, the diagnostic cut-off concentrations have

  2. Evaluation of a high-sensitivity assay for measurement of canine and feline serum cardiac troponin I

    DEFF Research Database (Denmark)

    Langhorn, Rebecca; Willesen, Jakob; Tarnow, Inge

    2013-01-01

    Cardiac troponins are established as the gold standard biomarkers for acute cardiac injury. As even small elevations of cardiac troponins have prognostic relevance in people, it is important to investigate the performance of sensitive assays for use in veterinary medicine....

  3. High?Sensitivity Troponin: A Clinical Blood Biomarker for Staging Cardiomyopathy in Fabry Disease

    OpenAIRE

    2016-01-01

    Background High?sensitivity troponin (hs?TNT), a biomarker of myocardial damage, might be useful for assessing fibrosis in Fabry cardiomyopathy. We performed a prospective analysis of hs?TNT as a biomarker for myocardial changes in Fabry patients and a retrospective longitudinal follow?up study to assess longitudinal hs?TNT changes relative to fibrosis and cardiomyopathy progression. Methods and Results For the prospective analysis, hs?TNT from 75 consecutive patients with genetically confirm...

  4. Combined determination of highly sensitive troponin T and copeptin for early exclusion of acute myocardial infarction: first experience in an emergency department of a general hospital

    Directory of Open Access Journals (Sweden)

    Lotze U

    2011-08-01

    Full Text Available Ulrich Lotze1, Holger Lemm2, Anke Heyer2, Karin Müller31Department of Internal Medicine, German Red Cross Hospital Sondershausen, Sondershausen, 2Department of Internal Medicine, 3Department of Laboratory Medicine, Saale-Unstrut Hospital Naumburg, Naumburg, GermanyBackground: The purpose of this observational study was to test the diagnostic performance of the Elecsys® troponin T high-sensitive system combined with copeptin measurement for early exclusion of acute myocardial infarction (MI in clinical practice.Methods: Troponin T high-sensitive (diagnostic cutoff: <14 pg/mL and copeptin (diagnostic cutoff: <14 pmol/L levels were determined at admission in addition to other routine laboratory parameters in patients with suspected acute MI presenting to the emergency department of a general hospital over a period of five months.Results: Data from 142 consecutive patients (mean age 71.2 ± 13.5 years, 76 men were analyzed. Final diagnoses were acute MI in 13 patients (nine ST elevation MI, four non-ST elevation MI, 9.2% unstable angina pectoris in three (2.1%, cardiac symptoms not primarily associated with myocardial ischemia in 79 (55.6%, and noncardiac disease in 47 patients (33.1%. The patients with acute MI were younger and had higher troponin T high-sensitive and copeptin values than patients without acute MI. Seventeen patients had very high copeptin values (>150 pmol/L, one of whom had a level of >700 pmol/L and died of pulmonary embolism. A troponin T high-sensitive level of <14 pg/mL in combination with copeptin <14 pmol/L at initial presentation ruled out acute MI in 45 of the 142 patients (31.7%, each with a sensitivity and negative predictive value of 100%.Conclusion: According to this early experience, a single determination of troponin T high-sensitive and copeptin may enable early and accurate exclusion of acute MI in one third of patients, even in an emergency department of a general hospital.Keywords: highly sensitive troponin T

  5. What to do when you question cardiac troponin values

    DEFF Research Database (Denmark)

    Mair, Johannes; Lindahl, Bertil; Müller, Christian

    2017-01-01

    High-sensitivity cardiac troponin assays enable cardiac troponin measurement with a high degree of analytical sensitivity and a low level of analytical imprecision at the low measuring range. One of the most important advantages of these new assays is that they allow novel, more rapid approaches...... for ruling in or ruling out acute myocardial infarctions. The increase in the early diagnostic sensitivity of high-sensitivity cardiac troponin assays comes at the cost of a reduced acute myocardial infarction specificity of the biomarker, because more patients with other causes of acute or chronic...... of the work-up for such a clinical setting....

  6. Effectiveness of 2-hour Troponin in High-risk Patients With Suspected Acute Coronary Syndrome.

    Science.gov (United States)

    Bove, Joseph; Hochman, Steven; Miller, Jacob; Artim, Stephen

    2017-06-01

    Research has shown the safety and effectiveness of drawing a standard troponin level at presentation and again at 2 hours in only low-risk patients. Because high-sensitivity troponins are not currently approved in the United States, we studied the utility of a standard troponin that is presently in use. Our goal was to determine if 2-hour standard troponin would be safe and effective in the evaluation of a high-risk cohort of patients never studied previously. We conducted a single-center prospective observational study of adult patients presenting to the emergency department with signs and symptoms suggestive of acute coronary syndrome. Patients were defined as high risk if the attending physician planned to admit or transfer the patient to the observation unit. History, Electrocardiography, Age, Risk factors, Troponin scores were calculated on all patients to provide verification that the individuals were high risk. The primary outcome was a composite of 30-day myocardial infarction, death, cardiac arrest with return of spontaneous circulation, or dysrhythmia. The secondary outcome was 30-day revascularization. We included a total of 122 patients with an average follow-up of 112 days (minimum 30 days). A total of 86% of cases had History, Electrocardiography, Age, Risk factors, Troponin scores ≥4. The primary outcome was met in 22 (18%) patients, and the secondary outcome occurred in 7 (5.7%) patients. The negative predictive value of negative 2-hour troponins along with no significant delta troponin rise was 98.7%. Discharging patients thought to be high risk who have negative troponins at 0 and 2 hours and no delta troponin rise appears safe. No deaths occurred in follow-up. Larger studies are warranted.

  7. Drug-Induced Rhabdomyolysis with Elevated Cardiac Troponin T

    Directory of Open Access Journals (Sweden)

    Gro Egholm

    2015-01-01

    Full Text Available The essential role of cardiac troponin in the diagnosis of acute myocardial infarction has led to the development of high-sensitivity assays, which are able to detect very small amounts of myocardial necrosis. The high-sensitivity cardiac troponin T assay, however, is not entirely specific for myocardial injury. This case report describes a 48-year-old woman, who, two years after cardiac transplantation, presented with rhabdomyolysis. During the course of the disease, her troponin T level was elevated on repeated occasions, but other definitive evidence of myocardial injury was not found. Asymptomatic cardiac troponin T elevations during rhabdomyolysis may be due to either cardiac involvement or false positive results stemming from skeletal muscle injury.

  8. Detection of high-sensitivity troponin in outpatients with stable pulmonary hypertension identifies a subgroup at higher risk of adverse outcomes.

    Science.gov (United States)

    Roy, Andrew K; McCullagh, Brian N; Segurado, Ricardo; McGorrian, Catherine; Keane, Elizabeth; Keaney, John; Fitzgibbon, Maria N; Mahon, Niall G; Murray, Patrick T; Gaine, Sean P

    2014-01-01

    The detection of elevations in cardiorenal biomarkers, such as troponins, B-type natriuretic peptides (BNPs), and neutrophil gelatinase-associated lipocalins, are associated with poor outcomes in patients hospitalized with acute heart failure. Less is known about the association of these markers with adverse events in chronic right ventricular dysfunction due to pulmonary hypertension, or whether their measurement may improve risk assessment in the outpatient setting. We performed a cohort study of 108 patients attending the National Pulmonary Hypertension Unit in Dublin, Ireland, from 2007 to 2009. Cox proportional hazards analysis and receiver operating characteristic curves were used to determine predictors of mortality and hospitalization. Death or hospitalization occurred in 50 patients (46.3%) during the median study period of 4.1 years. Independent predictors of mortality were: 1) decreasing 6-minute walk test (6MWT; hazard ratio [HR] 12.8; P < .001); 2) BNP (HR 6.68; P < .001); and 3) highly sensitive troponin (hsTnT; HR 5.48; P < .001). Adjusted hazard analyses remained significant when hsTnT was added to a model with BNP and 6MWT (HR 9.26, 95% CI 3.61-23.79), as did the predictive ability of the model for death and rehospitalization (area under the receiver operating characteristic curve 0.81, 95% CI 0.73-0.90). Detection of troponin using a highly sensitive assay identifies a pulmonary hypertension subgroup with a poorer prognosis. hsTnT may also be used in a risk prediction model to identify patients at higher risk who may require escalation of targeted pulmonary vasodilator therapies and closer clinical surveillance. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Temporal seizure focus and status epilepticus are associated with high-sensitive troponin I elevation after epileptic seizures.

    Science.gov (United States)

    Chatzikonstantinou, Anastasios; Ebert, Anne D; Hennerici, Michael G

    2015-09-01

    Postictal elevation of high-sensitive troponin I (TNI), a highly specific biomarker for myocardial ischemia, has been reported. We aimed at evaluating its association of high-sensitive troponin I (TNI) with seizure type and focus, as well as vascular risk factors. TNI was measured in 247 patients admitted to our clinic via the emergency room with an acute epileptic seizure. TNI control measurements were performed in 61.5% of cases. All patients underwent electroencephalography and cerebral imaging. Seizure focus - when possible - was determined using results from these examinations as well as clinical data. Of 247 patients, 133 (53.8%) were men, the mean age was 59 ± 18 years. 70 (28.3%) patients had focal and 177 (71.7%) generalized seizures. Status epilepticus was present in 38 cases (15.4%). Mean TNI was 0.05 ± 0.17. TNI was elevated in 27 patients (10.9%). Higher age, status epilepticus and temporal seizure focus were significantly associated with TNI elevation in multivariate analysis. In 21 (13.8%) of the patients with TNI control measurement, TNI was continuously elevated. Higher age and temporal seizure focus were significantly associated with continuously high TNI. Coronary heart disease and vascular risk factors were significantly associated with high TNI only in univariate analysis. No patient had a symptomatic myocardial ischemia. Postictal TNI elevation is relatively common in older patients with status epilepticus or temporal seizure focus. These data support the concept of relevant and possibly dangerous ictal effects on cardiac function especially in temporal lobe seizures. Although the risk of manifest postictal myocardial infarction seems to be very low, selected patients could profit from closer monitoring. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. A novel diagnostic protocol to identify patients suitable for discharge after a single high-sensitivity troponin

    Science.gov (United States)

    Carlton, Edward W; Cullen, Louise; Than, Martin; Gamble, James; Khattab, Ahmed; Greaves, Kim

    2015-01-01

    Objective To establish whether a novel accelerated diagnostic protocol (ADP) for suspected acute coronary syndrome (ACS) could successfully identify low-risk patients suitable for discharge after a single high-sensitivity troponin T (hs-cTnT) taken at presentation to the emergency department. We also compared the diagnostic accuracy of this ADP with strategies using initial undetectable hs-cTnT. Methods This prospective observational study evaluated the ability of the Triage Rule-out Using high-Sensitivity Troponin (TRUST) ADP to identify low-risk patients with suspected ACS. The ADP incorporated a single presentation hs-cTnT of <14 ng/L, a non-ischaemic ECG and a modified Goldman risk score. Diagnostic performance of the ADP was compared with the detection limit cut-offs of hs-cTnT (<5 ng/L and <3 ng/L). The primary end point was fatal/non-fatal acute myocardial infarction (AMI) within 30 days. Results 960 participants were recruited, mean age 58.0 years, 80 (8.3%) had an AMI. The TRUST ADP classified 382 (39.8%) as low-risk with a sensitivity for identifying AMI of 98.8% (95% CI 92.5% to 99.9%). hs-cTnT detection limits (<5 ng/L and <3 ng/L) had a sensitivity of 100% (94.3 to 100) and 100% (94.4 to 100), respectively. The TRUST ADP identified more patients suitable for early discharge at 39.8% vs 29.3% (<5 ng/L) and 7.9% (<3 ng/L) (p<0.001) with a lower false-positive rate for AMI detection; specificity 43.3% (95% CI 42.7% to 43.4%) vs 32.0% (95% CI 31.5% to 32.0%) and 8.6% (95% CI 8.1% to 8.6%), respectively. Conclusions The TRUST ADP, which incorporates structured risk-assessment and a single presentation hs-cTnT blood draw, has potential to allow early discharge in 40% of patients with suspected ACS and has greater clinical utility than undetectable hs-cTnT strategies. Trial registration number ISRCTN No. 21109279. PMID:25691511

  11. Sensitive Troponin I Assay in Patients with Chest Pain - Association with Significant Coronary Lesions with or Without Renal Failure.

    Science.gov (United States)

    Soeiro, Alexandre de Matos; Gualandro, Danielle Menosi; Bossa, Aline Siqueira; Zullino, Cindel Nogueira; Biselli, Bruno; Soeiro, Maria Carolina Feres de Almeida; Leal, Tatiana de Carvalho Andreucci Torres; Serrano, Carlos Vicente; Oliveira Junior, Mucio Tavares de

    2018-01-01

    Despite having higher sensitivity as compared to conventional troponins, sensitive troponins have lower specificity, mainly in patients with renal failure. Study aimed at assessing the sensitive troponin I levels in patients with chest pain, and relating them to the existence of significant coronary lesions. Retrospective, single-center, observational. This study included 991 patients divided into two groups: with (N = 681) and without (N = 310) significant coronary lesion. For posterior analysis, the patients were divided into two other groups: with (N = 184) and without (N = 807) chronic renal failure. The commercial ADVIA Centaur® TnI-Ultra assay (Siemens Healthcare Diagnostics) was used. The ROC curve analysis was performed to identify the sensitivity and specificity of the best cutoff point of troponin as a discriminator of the probability of significant coronary lesion. The associations were considered significant when p renal failure, the areas under the ROC curve were 0.703 (95% CI: 0.66 - 0.74) and 0.608 (95% CI: 0.52 - 0.70), respectively. The best cutoff points to discriminate the presence of significant coronary lesion were: in the general population, 0.605 ng/dL (sensitivity, 63.4%; specificity, 67%); in patients without renal failure, 0.605 ng/dL (sensitivity, 62.7%; specificity, 71%); and in patients with chronic renal failure, 0.515 ng/dL (sensitivity, 80.6%; specificity, 42%). In patients with chest pain, sensitive troponin I showed a good correlation with significant coronary lesions when its level was greater than 0.605 ng/dL. In patients with chronic renal failure, a significant decrease in specificity was observed in the correlation of troponin levels and severe coronary lesions.

  12. How is cardiac troponin released from injured myocardium?

    DEFF Research Database (Denmark)

    Mair, Johannes; Lindahl, Bertil; Hammarsten, Ola

    2017-01-01

    Cardiac troponin I and cardiac troponin T are nowadays the criterion biomarkers for the laboratory diagnosis of acute myocardial infarction due to their very high sensitivities and specificities for myocardial injury. However, still many aspects of their degradation, tissue release and eliminatio...

  13. Early diagnosis of myocardial infarction using absolute and relative changes in cardiac troponin concentrations

    OpenAIRE

    Irfan Affan Bin; Reichlin Tobias R.; Twerenbold Raphael; Meister Marc; Moehring Berit; Wildi Karin; Bassetti Stefano; Zellweger Christa; Gimenez Maria Rubini; Hoeller Rebeca; Murray Karsten; Sou SeoungMann; Mueller Mira; Mosimann Tamina; Reiter Miriam

    2013-01-01

    Background: Absolute changes in high sensitivity cardiac troponin T (hs cTnT) seem to have higher diagnostic accuracy in the early diagnosis of acute myocardial infarction compared with relative changes. It is unknown whether the same applies to high sensitivity cardiac troponin I (hs cTnI) assays and whether the combination of absolute and relative change might further increase accuracy. Methods: In a prospective international multicenter study high sensitivity cardiac troponin (hs cTn) was ...

  14. Comparison of cardiac troponins I and T measured with high-sensitivity methods for evaluation of prognosis in atrial fibrillation: an ARISTOTLE substudy.

    Science.gov (United States)

    Hijazi, Ziad; Siegbahn, Agneta; Andersson, Ulrika; Lindahl, Bertil; Granger, Christopher B; Alexander, John H; Atar, Dan; Gersh, Bernard J; Hanna, Michael; Harjola, Veli-Pekka; Horowitz, John; Husted, Steen; Hylek, Elaine M; Lopes, Renato D; McMurray, John J V; Wallentin, Lars

    2015-02-01

    Although cardiac troponin is associated with outcomes in atrial fibrillation (AF), the complementary prognostic information provided by cardiac troponin I (cTnI) and cTnT is unknown. This study investigated the distribution, determinants, and prognostic value of cTnI and cTnT concentrations in patients with AF. Samples were collected. At the time of randomization, we analyzed cTnI and cTnT concentrations of 14806 AF patients in the Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation (ARISTOTLE) trial using high-sensitivity assays. Correlations (Spearman), determinants (multivariable linear regression), and outcomes (adjusted Cox models and c-statistics) were investigated. Concentrations of cTnI and cTnT were correlated (r = 0.70) and measurable in most participants [cTnI 98.5% (median 5.4 ng/L, ≥99th percentile in 9.2%) and cTnT 93.5% (median 10.9 ng/L, ≥99th percentile in 34.4%)]. Renal impairment was the most important factor affecting the concentrations of both troponins. cTnI increase was more associated with heart failure, vascular disease, and persistent/permanent AF, and cTnT with age, male sex, and diabetes. Over a median 1.9 years of follow-up, patients with both troponins above the median had significantly higher risk for stroke/systemic embolism [hazard ratio (HR) 1.72 (95% CI 1.31-2.27)], cardiac death [3.14 (2.35-4.20)], and myocardial infarction [2.99 (1.78-5.03)] than those with both troponins below median (all P Chemistry.

  15. Determinants and prognostic implications of Cardiac Troponin T measured by a sensitive assay in Type 2 Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Hallén Jonas

    2010-09-01

    Full Text Available Abstract Background The cardiac troponins are biomarkers used for diagnosis of myocardial injury. They are also powerful prognostic markers in many diseases and settings. Recently introduced high-sensitivity assays indicate that chronic cardiac troponin elevations are common in response to cardiovascular (CV morbidity. Type 2 diabetes mellitus (T2DM confers a high risk of CV disease, but little is known about chronic cardiac troponin elevations in diabetic subjects. Accordingly, we aimed to understand the prevalence, determinants, and prognostic implications of cardiac troponin T (cTnT elevations measured with a high-sensitivity assay in patients with T2DM. Methods cTnT was measured in stored, frozen serum samples from 124 subjects enrolled in the Asker and Bærum Cardiovascular Diabetes trial at baseline and at 2-year follow-up, if availabe (96 samples available. Results were analyzed in relation to baseline variables, hospitalizations, and group assignment (multifactorial intensive versus conventional diabetes care for lowering CV risk. Results One-hundred thirteen (90 % had detectable cTnT at baseline and of those, 22 (18 % of the total population subjects had values above the 99th percentile for healthy controls (13.5 ng/L. Levels at baseline were associated with conventional CV risk factors (age, renal function, gender. There was a strong correlation between cTnT levels at the two time-points (r = 0.92, p > 0.001. Risk for hospitalizations during follow-up increased step-wise by quartiles of hscTnT measured at baseline (p = 0.058. Conclusions Elevations of cTnT above the 99th percentile measured by a highly sensitive assay were encountered frequently in a population of T2DM patients. cTnT levels appeared to be stable over time and associated with conventional CV risk factors. Although a clear trend was present, no statistically robust associations with adverse outcomes could be found.

  16. Cardiac troponins in dogs and cats

    DEFF Research Database (Denmark)

    Langhorn, Rebecca; Willesen, Jakob

    2016-01-01

    Cardiac troponins are sensitive and specific markers of myocardial injury. The troponin concentration can be thought of as a quantitative measure of the degree of injury sustained by the heart, however, it provides no information on the cause of injury or the mechanism of troponin release. Conven...

  17. High-sensitivity cardiac troponin I assay to screen for acute rejection in patients with heart transplant.

    Science.gov (United States)

    Patel, Parag C; Hill, Douglas A; Ayers, Colby R; Lavingia, Bhavna; Kaiser, Patricia; Dyer, Adrian K; Barnes, Aliessa P; Thibodeau, Jennifer T; Mishkin, Joseph D; Mammen, Pradeep P A; Markham, David W; Stastny, Peter; Ring, W Steves; de Lemos, James A; Drazner, Mark H

    2014-05-01

    A noninvasive biomarker that could accurately diagnose acute rejection (AR) in heart transplant recipients could obviate the need for surveillance endomyocardial biopsies. We assessed the performance metrics of a novel high-sensitivity cardiac troponin I (cTnI) assay for this purpose. Stored serum samples were retrospectively matched to endomyocardial biopsies in 98 cardiac transplant recipients, who survived ≥3 months after transplant. AR was defined as International Society for Heart and Lung Transplantation grade 2R or higher cellular rejection, acellular rejection, or allograft dysfunction of uncertain pathogenesis, leading to treatment for presumed rejection. cTnI was measured with a high-sensitivity assay (Abbott Diagnostics, Abbott Park, IL). Cross-sectional analyses determined the association of cTnI concentrations with rejection and International Society for Heart and Lung Transplantation grade and the performance metrics of cTnI for the detection of AR. Among 98 subjects, 37% had ≥1 rejection episode. cTnI was measured in 418 serum samples, including 35 paired to a rejection episode. cTnI concentrations were significantly higher in rejection versus nonrejection samples (median, 57.1 versus 10.2 ng/L; P<0.0001) and increased in a graded manner with higher biopsy scores (P(trend)<0.0001). The c-statistic to discriminate AR was 0.82 (95% confidence interval, 0.76-0.88). Using a cut point of 15 ng/L, sensitivity was 94%, specificity 60%, positive predictive value 18%, and negative predictive value 99%. A high-sensitivity cTnI assay seems useful to rule out AR in cardiac transplant recipients. If validated in prospective studies, a strategy of serial monitoring with a high-sensitivity cTnI assay may offer a low-cost noninvasive strategy for rejection surveillance. © 2014 American Heart Association, Inc.

  18. High-sensitivity troponin assays for the early rule-out or diagnosis of acute myocardial infarction in people eith acute chest pain: a systematic review and cost-effectiveness analysis

    NARCIS (Netherlands)

    M. Westwood (Marie); T. van Asselt (Thea); B. Ramaekers (Bram); P. Whiting (Penny); P. Tokala (Praveen); M.A. Joore (Manuela); N. Armstrong (Nigel); J. Ross (Janine); J.L. Severens (Hans); J. Kleijnen (Jos)

    2015-01-01

    textabstractBackground: Early diagnosis of acute myocardial infarction (AMI) can ensure quick and effective treatment but only 20% of adults with emergency admissions for chest pain have an AMI. High-sensitivity cardiac troponin (hs-cTn) assays may allow rapid rule-out of AMI and avoidance of

  19. High-sensitivity troponin assays for the early rule-out or diagnosis of acute myocardial infarction in people with acute chest pain : a systematic review and cost-effectiveness analysis

    NARCIS (Netherlands)

    Westwood, Marie; van Asselt, Thea; Ramaekers, Bram; Whiting, Penny; Thokala, Praveen; Joore, Manuela; Armstrong, Nigel; Ross, Janine; Severens, Johan; Kleijnen, Jos

    BACKGROUND: Early diagnosis of acute myocardial infarction (AMI) can ensure quick and effective treatment but only 20% of adults with emergency admissions for chest pain have an AMI. High-sensitivity cardiac troponin (hs-cTn) assays may allow rapid rule-out of AMI and avoidance of unnecessary

  20. Validation of an accelerated high-sensitivity troponin T assay protocol in an Australian cohort with chest pain.

    Science.gov (United States)

    Parsonage, William A; Greenslade, Jaimi H; Hammett, Christopher J; Lamanna, Arvin; Tate, Jillian R; Ungerer, Jacobus P; Chu, Kevin; Than, Martin; Brown, Anthony F T; Cullen, Louise

    2014-02-17

    To validate an accelerated biomarker strategy using a high-sensitivity cardiac troponin T (hs-cTnT) assay for diagnosing acute myocardial infarction (AMI) in patients presenting to the emergency department with chest pain; and to validate this strategy in combination with the National Heart Foundation of Australia/Cardiac Society of Australia and New Zealand risk stratification model. Single-centre, prospective, observational cohort study of 764 adults presenting to a tertiary hospital with symptoms of possible acute coronary syndrome between November 2008 and February 2011. AMI or cardiac death within 24 hours of presentation (primary), and major adverse cardiac events within 30 days (secondary). An elevated hs-cTnT assay result above the 99th percentile at either the 0 h or 2 h time points had sensitivity of 96.4% (95% CI, 87.9%-99.0%), specificity of 82.6% (95% CI, 79.7%-85.2%), negative predictive value of 99.7% (95% CI, 98.8%-99.9%) and positive predictive value of 30.5% (95% CI, 24.2%-37.6%) for diagnosing AMI. Compared with a traditional 6 h cardiac troponin testing strategy, the accelerated strategy led to reclassification of risk in only two patients with adverse cardiac outcomes, with no net effect on appropriate management. In patients presenting with chest pain, an accelerated biomarker strategy using the hs-cTnT assay performed well in the initial diagnosis of AMI. The accelerated strategy was also effective when incorporated into a comprehensive strategy of risk stratification that included clinical and demographic factors. The time saved by this approach could have a major impact on health service delivery. Australian New Zealand Clinical Trials Registry ACTRN12610000053022.

  1. Evaluation of analytical performance of a new high-sensitivity immunoassay for cardiac troponin I.

    Science.gov (United States)

    Masotti, Silvia; Prontera, Concetta; Musetti, Veronica; Storti, Simona; Ndreu, Rudina; Zucchelli, Gian Carlo; Passino, Claudio; Clerico, Aldo

    2018-02-23

    The study aim was to evaluate and compare the analytical performance of the new chemiluminescent immunoassay for cardiac troponin I (cTnI), called Access hs-TnI using DxI platform, with those of Access AccuTnI+3 method, and high-sensitivity (hs) cTnI method for ARCHITECT platform. The limits of blank (LoB), detection (LoD) and quantitation (LoQ) at 10% and 20% CV were evaluated according to international standardized protocols. For the evaluation of analytical performance and comparison of cTnI results, both heparinized plasma samples, collected from healthy subjects and patients with cardiac diseases, and quality control samples distributed in external quality assessment programs were used. LoB, LoD and LoQ at 20% and 10% CV values of the Access hs-cTnI method were 0.6, 1.3, 2.1 and 5.3 ng/L, respectively. Access hs-cTnI method showed analytical performance significantly better than that of Access AccuTnI+3 method and similar results to those of hs ARCHITECT cTnI method. Moreover, the cTnI concentrations measured with Access hs-cTnI method showed close linear regressions with both Access AccuTnI+3 and ARCHITECT hs-cTnI methods, although there were systematic differences between these methods. There was no difference between cTnI values measured by Access hs-cTnI in heparinized plasma and serum samples, whereas there was a significant difference between cTnI values, respectively measured in EDTA and heparin plasma samples. Access hs-cTnI has analytical sensitivity parameters significantly improved compared to Access AccuTnI+3 method and is similar to those of the high-sensitivity method using ARCHITECT platform.

  2. High-Sensitivity Troponin: A Clinical Blood Biomarker for Staging Cardiomyopathy in Fabry Disease.

    Science.gov (United States)

    Seydelmann, Nora; Liu, Dan; Krämer, Johannes; Drechsler, Christiane; Hu, Kai; Nordbeck, Peter; Schneider, Andreas; Störk, Stefan; Bijnens, Bart; Ertl, Georg; Wanner, Christoph; Weidemann, Frank

    2016-05-31

    High-sensitivity troponin (hs-TNT), a biomarker of myocardial damage, might be useful for assessing fibrosis in Fabry cardiomyopathy. We performed a prospective analysis of hs-TNT as a biomarker for myocardial changes in Fabry patients and a retrospective longitudinal follow-up study to assess longitudinal hs-TNT changes relative to fibrosis and cardiomyopathy progression. For the prospective analysis, hs-TNT from 75 consecutive patients with genetically confirmed Fabry disease was analyzed relative to typical Fabry-associated echocardiographic findings and total myocardial fibrosis as measured by late gadolinium enhancement (LE) on magnetic resonance imaging. Longitudinal data (3.9±2.0 years), including hs-TNT, LE, and echocardiographic findings from 58 Fabry patients, were retrospectively collected. Hs-TNT level positively correlated with LE (linear correlation coefficient, 0.72; odds ratio, 32.81 [95% CI, 3.56-302.59]; P=0.002); patients with elevated baseline hs-TNT (>14 ng/L) showed significantly increased LE (median: baseline, 1.9 [1.1-3.3] %; follow-up, 3.2 [2.3-4.9] %; PFabry disease and a qualified predictor of cardiomyopathy progression. Thus, hs-TNT could be helpful for staging and follow-up of Fabry patients. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  3. Diagnostic value of exercise-induced changes in circulating high sensitive troponin T in stable chest pain patients

    DEFF Research Database (Denmark)

    Mouridsen, Mette Rauhe; Nielsen, Olav Wendelboe; Pedersen, Ole Dyg

    2013-01-01

    We investigated the diagnostic value of exercise-induced increase in cardiac Troponin T (cTnT) in stable chest pain subjects.......We investigated the diagnostic value of exercise-induced increase in cardiac Troponin T (cTnT) in stable chest pain subjects....

  4. Prognostic implications of high-sensitivity cardiac troponin T assay in a real-world population with non-ST-elevation acute coronary syndrome.

    Science.gov (United States)

    Magnoni, Marco; Gallone, Guglielmo; Ceriotti, Ferruccio; Vergani, Vittoria; Giorgio, Daniela; Angeloni, Giulia; Maseri, Attilio; Cianflone, Domenico

    2018-09-01

    High-sensitivity cardiac troponin T (hsTnT) was recently approved for clinical use by the Food and Drug Administration. The transition from contemporary to hsTnT assays requires a thorough understanding of the clinical differences between these assays. HsTnT may provide a more accurate prognostic stratification than contemporary cardiac troponin I (cTnI) in patients with non-ST-segment elevation acute coronary syndromes (NSTE-ACS). HsTnT and cTnI were measured in 644 patients with CK-MB negative NSTE-ACS who were enrolled in the prospective multicenter SPAI (Stratificazione Prognostica dell'Angina Instabile) study. Patients were stratified at the 99th percentile reference limit for each assay. The primary endpoint was cardiovascular death (CVD) or non-fatal myocardial infarction (MI); the secondary endpoint was the occurrence of unstable angina (UA). Follow-up lasted 180 days. Patients with hsTnT ≥99th percentile were at higher risk of CVD/MI (30-day: 5.9% vs 0.8%, p  = 0.001; 180-day: 11.1% vs 4.7%, p  = 0.004), also after adjusting for TIMI Risk Score. No significant difference in CVD/MI at 180-day was found between hsTnT-positive/cTnI-negative and hsTnT-negative/cTnI-negative patients (adjHR 1.61, 95% CI 0.74-3.49, p  = 0.232). Occurrence of UA was not differently distributed between hsTnT groups dichotomized at the 99th percentile (12.4% vs 12.5% p  = 0.54). Our investigation on a real-world NSTE-ACS population showed good prognostic performance of hsTnT in the risk stratification of the hard endpoint, but did not demonstrate the improved prognostic ability of hsTnT over contemporary cTn. Neither troponin assay predicted the recurrence of UA, suggesting the acute rise of cardiac troponin as a marker of severity, but not the occurrence of future coronary instability.

  5. Serial measurements of high sensitive cardiac troponin I in patients with acutely decompensated heart failure treated with carperitide or nitrates.

    Science.gov (United States)

    Sato, Yukihito; Nishi, Kiyoto; Saijo, Sayaka; Tanada, Yohei; Goto, Taisuke; Takahashi, Naoki; Yamamoto, Erika; Fukuhara, Rei; Miyamoto, Tadashi; Taniguchi, Ryoji; Fujiwara, Hisayoshi; Takatsu, Yoshiki

    2010-07-01

    In patients with acutely decompensated heart failure (ADHF), elevated serum concentration of cardiac troponin is an independent predictor of adverse cardiac events. In ADHF with a preserved systolic blood pressure, treatment with intravenous vasodilator is recommended. However, the effect of vasodilators on troponin concentrations has not been elucidated well. Serial high sensitive cardiac troponin I (hs-TnI) was measured in 36 patients presenting with ADHF and preserved systolic blood pressure, of whom 20 were treated with atrial natriuretic peptide (ANP) and 16 with nitrates. The concentrations of hs-TnI ranged from 0.069+/-0.114ng/ml at baseline to 0.076+/-0.121ng/ml at 5h, 0.062+/-0.106ng/ml at 1 day, and 0.056+/-0.089ng/ml at day 7 (n=36,ns). The relative change in hs-TnI between baseline and at 5h, day 1 and day 7 were 1.13+/-0.43, 0.95+/-0.44 and 0.93+/-0.64 in patients treated with ANP, and 1.02+/-0.19, 0.95+/-0.31 and 1.19+/-1.38 in patients treated with nitrates (ns; ANP versus nitrates). On day 7, a hs-TnI change, >20% decrease from baseline, was observed in 55% patients with ANP versus 56% patients with nitrates (ns). The cardiac event rates were similar in both groups. In ADHF patients with preserved systolic blood pressure, the administration of intravenous vasodilators did not decrease hs-TnI over the first 7 days. Treatments with ANP and nitrates were associated with similar short-term decreases in hs-TnI and long-term adverse cardiac events. Copyright 2010 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  6. The diagnostic value of troponin in critically ill.

    Science.gov (United States)

    Voga, Gorazd

    2010-01-01

    Troponin T and I are sensitive and specific markers of myocardial necrosis. They are used for the routine diagnosis of acute coronary syndrome. In critically ill patients they are basic diagnostic tool for diagnosis of myocardial necrosis due to myocardial ischemia. Moreover, the increase of troponin I and T is related with adverse outcome in many subgroups of critically ill patients. The new, high sensitivity tests which have been developed recently allow earlier and more accurate diagnosis of acute coronary syndrome. The use of the new tests has not been studied in critically ill patients, but they will probably replace the old tests and will be used on the routine basis.

  7. Clinical features and prognosis of patients with acute non-specific chest pain in emergency and cardiology departments after the introduction of high-sensitivity troponins

    DEFF Research Database (Denmark)

    Ilangkovan, Nivethitha; Mickley, Hans; Diederichsen, Axel

    2017-01-01

    OBJECTIVES: To determine the incidence of clinical, cardiac-related endpoints and mortality among patients presenting to an emergency or cardiology department with non-specific chest pain (NSCP), and who receive testing with a high-sensitivity troponin. A second objective was to identify risk...... factors for the above-noted endpoints during 12 months of follow-up. DESIGN: A prospective multicentre study. SETTING: Emergency and cardiology departments in Southern Denmark. SUBJECTS: The study enrolled 1027 patients who were assessed for acute chest pain in an emergency or cardiology department...

  8. Cardiospecific troponins in non-ischemic cardiological pathologies

    Directory of Open Access Journals (Sweden)

    Giuseppe Lippi

    2006-10-01

    Full Text Available Cardiospecific troponin T (TnT and I (TnI are low-molecularweight proteins that form part of the troponin complex and are integral components of the myofibrillar contractile apparatus of the heart. Loss of integrity of cardiac myocyte membranes causes release of cardiac troponins into the circulation, which can be detected by highly sensitive assays for cTnT and cTnI developed to the stat diagnosis of acute coronary syndrome. Regardless of preanalytical and analytical sources (incorrect collection or handling of the specimen, malfunctioning of the analyzer, heterophilic antibodies, a diagnostic troponin value is expression of myocardial damage, though it does not provide definitive clue on the nature of such an increment. In fact, increases in serum cardiac troponins also occur in the absence of cardiac ischemia and may sometimes led to an inappropriate or unjustified clinical decision making. Abnormal troponin values in plasma are frequently observed in various clinical contexts independent from the acute coronary disease, like myocarditis, pulmonary embolism, acute heart failure, septic shock, and as a result of cardiotoxic drugs as well as after therapeutic procedures like coronary angioplasty, electrophysiological ablations, or electrical cardioversion. Awareness of this issue is essential to either prevent unjustified alarmism or underestimation of clinical situations that may finally compromise the patient’s health.

  9. Upconverting nanophosphors as reporters in a highly sensitive heterogeneous immunoassay for cardiac troponin I

    Energy Technology Data Exchange (ETDEWEB)

    Sirkka, Nina, E-mail: nkelon@utu.fi; Lyytikäinen, Annika; Savukoski, Tanja; Soukka, Tero

    2016-06-21

    Photon upconverting nanophosphors (UCNPs) have a unique capability to produce anti-Stokes emission at visible wavelengths via sequential multiphoton absorption upon infrared excitation. Since the anti-Stokes emission can be easily spectrally resolved from the Stokes' shifted autofluorescence, the upconversion luminescence (UCL) is a highly attractive reporter technology for optical biosensors and biomolecular binding assays – potentially enabling unprecedented sensitivity in separation-based solid-phase immunoassays. UCL technology has not previously been applied in sensitive detection of cardiac troponin I (cTnI), which requires highly sensitive detection to enable accurate and timely diagnosis of myocardial infarction. We have developed an UCL-based immunoassay for cTnI using NaYF{sub 4}: Yb{sup 3+}, Er{sup 3+} UCNPs as reporters. Biotinylated anti-cTnI monoclonal antibody (Mab) and Fab fragment immobilized to streptavidin-coated wells were used to capture cTnI. Captured cTnI was detected from dry well surface after a 15 min incubation with poly(acrylic acid) coated UCNPs conjugated to second anti-cTnI Mab. UCL was measured with a dedicated UCL microplate reader. The UCL-based immunoassay allowed sensitive detection of cTnI. The limit of detection was 3.14 ng L{sup −1}. The calibration curve was linear up to cTnI concentration 50,000 ng L{sup −1}. Plasma recoveries of added cTnI were 92–117%. Obtained cTnI concentrations from five normal plasma samples were 4.13–10.7 ng L{sup −1} (median 5.06 ng L{sup −1}). There is yet significant potential for even further improved limit of detection by reducing non-specifically bound fraction of the Mab-conjugated UCNPs. The assay background with zero calibrator was over 40-fold compared to the background obtained from wells where the reporter conjugate had been excluded. - Highlights: • Detection of attomole analyte quantity in microwell using upconversion luminescence. • Upconverting

  10. Prediction of outcome by highly sensitive troponin T in outpatients with chronic systolic left ventricular heart failure

    DEFF Research Database (Denmark)

    Egstrup, Michael; Schou, Morten; Tuxen, Christian D

    2012-01-01

    Our aim was to assess the prognostic impact of a high-sensitivity cardiac troponin T (hs-cTnT) assay in an outpatient population with chronic systolic left ventricular heart failure (HF). Four hundred sixteen patients with chronic HF and left ventricular ejection fraction ≤ 45% were enrolled...... in a prospective cohort study. In addition to hs-cTnT, plasma amino-terminal pro-B-type natriuretic peptide was measured at baseline. Mean age was 71 years, 29% were women, 62% had coronary artery disease (CAD), mean left ventricular ejection fraction was 31%, and 57% had abnormal level of hs-cTnT. During 4.......4 years of follow-up, 211 (51%) patients died. In multivariate Cox regression models, hs-cTnT was categorized as quartiles or dichotomized by the 99th percentile of a healthy population. Adjusted hazard ratios for all-cause mortality for quartiles 2 to 4, with quartile 1 as reference, were 1.4 (95...

  11. Serial High-Sensitivity Troponin T in Post-Primary Angioplasty Exercise Test

    Directory of Open Access Journals (Sweden)

    Humberto Andres Vaz

    2016-04-01

    Full Text Available Abstract Background: The kinetics of high-sensitivity troponin T (hscTnT release should be studied in different situations, including functional tests with transient ischemic abnormalities. Objective: To evaluate the release of hscTnT by serial measurements after exercise testing (ET, and to correlate hscTnT elevations with abnormalities suggestive of ischemia. Methods: Patients with acute ST-segment elevation myocardial infarction (STEMI undergoing primary angioplasty were referred for ET 3 months after infarction. Blood samples were collected to measure basal hscTnT immediately before (TnT0h, 2 (TnT2h, 5 (TnT5h, and 8 hours (TnT8h after ET. The outcomes were peak hscTnT, TnT5h/TnT0h ratio, and the area under the blood concentration-time curve (AUC for hscTnT levels. Log-transformation was performed on hscTnT values, and comparisons were assessed with the geometric mean ratio, along with their 95% confidence intervals. Statistical significance was assessed by analysis of covariance with no adjustment, and then, adjusted for TnT0h, age and sex, followed by additional variables (metabolic equivalents, maximum heart rate achieved, anterior wall STEMI, and creatinine clearance. Results: This study included 95 patients. The highest geometric means were observed at 5 hours (TnT5h. After adjustments, peak hscTnT, TnT5h/TnT0h and AUC were 59% (p = 0.002, 59% (p = 0.003 and 45% (p = 0.003 higher, respectively, in patients with an abnormal ET as compared to those with normal tests. Conclusion: Higher elevations of hscTnT may occur after an abnormal ET as compared to a normal ET in patients with STEMI.

  12. Serial High-Sensitivity Troponin T in Post-Primary Angioplasty Exercise Test

    Energy Technology Data Exchange (ETDEWEB)

    Vaz, Humberto Andres, E-mail: humbertovaz@cardiol.br; Vanz, Ana Paula; Castro, Iran [Instituto de Cardiologia - Fundação Universitária de Cardiologia, Porto Alegre, RS (Brazil)

    2016-04-15

    The kinetics of high-sensitivity troponin T (hscTnT) release should be studied in different situations, including functional tests with transient ischemic abnormalities. To evaluate the release of hscTnT by serial measurements after exercise testing (ET), and to correlate hscTnT elevations with abnormalities suggestive of ischemia. Patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary angioplasty were referred for ET 3 months after infarction. Blood samples were collected to measure basal hscTnT immediately before (TnT{sub 0h}), 2 (TnT{sub 2h}), 5 (TnT{sub 5h}), and 8 hours (TnT{sub 8h}) after ET. The outcomes were peak hscTnT, TnT{sub 5h}/TnT{sub 0h} ratio, and the area under the blood concentration-time curve (AUC) for hscTnT levels. Log-transformation was performed on hscTnT values, and comparisons were assessed with the geometric mean ratio, along with their 95% confidence intervals. Statistical significance was assessed by analysis of covariance with no adjustment, and then, adjusted for TnT{sub 0h}, age and sex, followed by additional variables (metabolic equivalents, maximum heart rate achieved, anterior wall STEMI, and creatinine clearance). This study included 95 patients. The highest geometric means were observed at 5 hours (TnT{sub 5h}). After adjustments, peak hscTnT, TnT{sub 5h}/TnT{sub 0h} and AUC were 59% (p = 0.002), 59% (p = 0.003) and 45% (p = 0.003) higher, respectively, in patients with an abnormal ET as compared to those with normal tests. Higher elevations of hscTnT may occur after an abnormal ET as compared to a normal ET in patients with STEMI.

  13. Pragmatic approach to chest pain patients discharged with undetectable high-sensitivity troponin T and normal electrocardiogram: the STABS + CT protocol.

    Science.gov (United States)

    Bishop, Warrick; Girao, Gary

    2017-06-01

    A strategy that discharges chest pain patients with negative high-sensitivity troponin and non-ischaemic electrocardiography changes may still result in 0.44% of patients experiencing myocardial infarction within 30 days. We observed that a pragmatic approach that systematically discharged 25 patients on cardio-protective medications of aspirin, metoprolol and atorvastatin followed with prompt (<10 days) coronary computed tomography angiography resulted in no major adverse cardiac event and adverse drug reaction 30 days post-presentation. The strategy resulted in three patients (12%) ultimately diagnosed with likely unstable angina, which required planned coronary intervention in two patients and medical management in one patient. No unplanned readmissions for chest pains were noted from initial presentation through to 6-month follow up. © 2017 Royal Australasian College of Physicians.

  14. Age-adjusted high-sensitivity troponin T cut-off value for risk stratification of pulmonary embolism.

    Science.gov (United States)

    Kaeberich, Anja; Seeber, Valerie; Jiménez, David; Kostrubiec, Maciej; Dellas, Claudia; Hasenfuß, Gerd; Giannitsis, Evangelos; Pruszczyk, Piotr; Konstantinides, Stavros; Lankeit, Mareike

    2015-05-01

    High-sensitivity troponin T (hsTnT) helps in identifying pulmonary embolism patients at low risk of an adverse outcome. In 682 normotensive pulmonary embolism patients we investigate whether an optimised hsTnT cut-off value and adjustment for age improve the identification of patients at elevated risk. Overall, 25 (3.7%) patients had an adverse 30-day outcome. The established hsTnT cut-off value of 14 pg·mL(-1) retained its high prognostic value (OR (95% CI) 16.64 (2.24-123.74); p=0.006) compared with the cut-off value of 33 pg·mL(-1) calculated by receiver operating characteristic analysis (7.14 (2.64-19.26); pvalue of 45 pg·mL(-1) but not the established cut-off value of 14 pg·mL(-1) predicted an adverse outcome. An age-adjusted hsTnT cut-off value (≥14 pg·mL(-1) for patients aged risk (12.4% adverse outcome). Risk assessment of normotensive pulmonary embolism patients was improved by the introduction of an age-adjusted hsTnT cut-off value. A three-step approach helped identify patients at higher risk of an adverse outcome who might benefit from advanced therapy. Copyright ©ERS 2015.

  15. European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay

    DEFF Research Database (Denmark)

    Krintus, Magdalena; Kozinski, Marek; Boudry, Pascal

    2014-01-01

    BACKGROUND: International recommendations highlight the superior value of cardiac troponins (cTns) for early diagnosis of myocardial infarction along with analytical requirements of improved precision and detectability. In this multicenter study, we investigated the analytical performance of a ne...

  16. Point-of-care heart-type fatty acid binding protein versus high-sensitivity troponin T testing in emergency patients at high risk for acute coronary syndrome.

    Science.gov (United States)

    Kellens, Sebastiaan; Verbrugge, Frederik H; Vanmechelen, Maxime; Grieten, Lars; Van Lierde, Johan; Dens, Joseph; Vrolix, Mathias; Vandervoort, Pieter

    2016-04-01

    High-sensitivity cardiac troponin testing is used to detect myocardial damage in patients with acute chest pain. Heart-type fatty acid binding protein (H-FABP) may be an alternative, available as point-of-care test. Patients (n=203) referred by general practitioners for suspected acute coronary syndrome or presenting with typical chest pain and one major cardiovascular risk factor at the emergency department were prospectively included in a single-centre cohort study. High-sensitivity cardiac troponin T (hs-TnT) and point-of-care H-FABP testing were concomitantly performed at admission and after 6h. Maximal hs-TnT levels above the 99th percentile were observed in 152 patients (75%) with 127 (63%) fulfilling criteria for myocardial infarction. Upon admission, hs-TnT and H-FABP were associated with an area under the curve (95% CI) of 0.83 (0.77-0.89) and 0.79 (0.73-0.85), respectively, to predict myocardial infarction, which increased to 0.93 (0.90-0.97) and 0.88 (0.84-0.93), respectively, after 6h. The diagnostic accuracy for non-ST-segment elevation myocardial infarction was somewhat lower with an area under the curve (95% CI) of 0.80 (0.72-0.87), 0.90 (0.84-0.96), 0.73 (0.64-0.81) and 0.77 (0.67-0.86), respectively. When assessment was performed within 3h of chest pain onset, diagnostic accuracy of H-FABP versus hs-TnT was similar. Each standard deviation increase in admission H-FABP was associated with a 68% relative risk increase of all-cause mortality (p-value=0.027) during 666 ± 155 days of follow-up. Point-of-care H-FABP testing has lower diagnostic accuracy compared with hs-TnT assessment in patients with high pre-test acute coronary syndrome probability, but might be of interest when assessment is possible early after chest pain onset. © The European Society of Cardiology 2015.

  17. Preprocedural High-Sensitivity Cardiac Troponin T and Clinical Outcomes in Patients With Stable Coronary Artery Disease Undergoing Elective Percutaneous Coronary Intervention.

    Science.gov (United States)

    Zanchin, Thomas; Räber, Lorenz; Koskinas, Konstantinos C; Piccolo, Raffaele; Jüni, Peter; Pilgrim, Thomas; Stortecky, Stefan; Khattab, Ahmed A; Wenaweser, Peter; Bloechlinger, Stefan; Moschovitis, Aris; Frenk, Andre; Moro, Christina; Meier, Bernhard; Fiedler, Georg M; Heg, Dik; Windecker, Stephan

    2016-06-01

    Cardiac troponin detected by new-generation, highly sensitive assays predicts clinical outcomes among patients with stable coronary artery disease (SCAD) treated medically. The prognostic value of baseline high-sensitivity cardiac troponin T (hs-cTnT) elevation in SCAD patients undergoing elective percutaneous coronary interventions is not well established. This study assessed the association of preprocedural levels of hs-cTnT with 1-year clinical outcomes among SCAD patients undergoing percutaneous coronary intervention. Between 2010 and 2014, 6974 consecutive patients were prospectively enrolled in the Bern Percutaneous Coronary Interventions Registry. Among patients with SCAD (n=2029), 527 (26%) had elevated preprocedural hs-cTnT above the upper reference limit of 14 ng/L. The primary end point, mortality within 1 year, occurred in 20 patients (1.4%) with normal hs-cTnT versus 39 patients (7.7%) with elevated baseline hs-cTnT (P<0.001). Patients with elevated hs-cTnT had increased risks of all-cause (hazard ratio 5.73; 95% confidence intervals 3.34-9.83; P<0.001) and cardiac mortality (hazard ratio 4.68; 95% confidence interval 2.12-10.31; P<0.001). Preprocedural hs-TnT elevation remained an independent predictor of 1-year mortality after adjustment for relevant risk factors, including age, sex, and renal failure (adjusted hazard ratio 2.08; 95% confidence interval 1.10-3.92; P=0.024). A graded mortality risk was observed across higher tertiles of elevated preprocedural hs-cTnT, but not among patients with hs-cTnT below the upper reference limit. Preprocedural elevation of hs-cTnT is observed in one fourth of SCAD patients undergoing elective percutaneous coronary intervention. Increased levels of preprocedural hs-cTnT are proportionally related to the risk of death and emerged as independent predictors of all-cause mortality within 1 year. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02241291. © 2016 American Heart Association, Inc.

  18. Diagnostic and prognostic value of high-sensitivity cardiac troponin T in patients with syncope.

    Science.gov (United States)

    Christ, Michael; Geier, Felicitas; Popp, Steffen; Singler, Katrin; Smolarsky, Alexander; Bertsch, Thomas; Müller, Christian; Greve, Yvonne

    2015-02-01

    We examined the diagnostic and predictive value of high-sensitivity cardiac troponin T (cTnThs) in patients with syncope. We performed an analysis of consecutive patients with syncope presenting to the emergency department. The primary end point was the accuracy to diagnose a cardiac syncope. In addition, the study explored the prognostic relevance of cTnThs in patients with cardiac and noncardiac syncope. A total of 360 patients were enrolled (median age, 70.5 years; male, 55.8%; 23.9% aged >80 years). Cardiac syncope was present in 22% of patients, reflex syncope was present in 40% of patients, syncope due to orthostatic hypotension was present in 20% of patients, and unexplained syncope was present in 17.5% of patients. A total of 148 patients (41%) had cTnThs levels above the 99% confidence interval (CI) (cutoff point). The diagnostic accuracy for cTnThs levels to determine the diagnosis of cardiac syncope was quantified by the area under the curve (0.77; CI, 0.72-0.83; P value of cTnThs levels within 30 days: Patients with increased cTnThs levels had a 52% likelihood for adverse events, patients with cTnThs levels below the cutoff point had a low risk (negative predictive value, 83.5%). Increased cTnThs levels indicate adverse prognosis in patients with noncardiac causes of syncope, but not in patients with cardiac syncope being a risk factor for adverse outcome by itself. Patients with syncope presenting to the emergency department have a high proportion of life-threatening conditions. cTnThs levels show a limited diagnostic and predictive accuracy for the identification of patients with syncope at high risk. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Dynamic Equilibrium of Cardiac Troponin C's Hydrophobic Cleft and Its Modulation by Ca2+ Sensitizers and a Ca2+ Sensitivity Blunting Phosphomimic, cTnT(T204E).

    Science.gov (United States)

    Schlecht, William; Dong, Wen-Ji

    2017-10-18

    Several studies have suggested that conformational dynamics are important in the regulation of thin filament activation in cardiac troponin C (cTnC); however, little direct evidence has been offered to support these claims. In this study, a dye homodimerization approach is developed and implemented that allows the determination of the dynamic equilibrium between open and closed conformations in cTnC's hydrophobic cleft. Modulation of this equilibrium by Ca 2+ , cardiac troponin I (cTnI), cardiac troponin T (cTnT), Ca 2+ -sensitizers, and a Ca 2+ -desensitizing phosphomimic of cTnT (cTnT(T204E) is characterized. Isolated cTnC contained a small open conformation population in the absence of Ca 2+ that increased significantly upon the addition of saturating levels of Ca 2+ . This suggests that the Ca 2+ -induced activation of thin filament arises from an increase in the probability of hydrophobic cleft opening. The inclusion of cTnI increased the population of open cTnC, and the inclusion of cTnT had the opposite effect. Samples containing Ca 2+ -desensitizing cTnT(T204E) showed a slight but insignificant decrease in open conformation probability compared to samples with cardiac troponin T, wild type [cTnT(wt)], while Ca 2+ sensitizer treated samples generally increased open conformation probability. These findings show that an equilibrium between the open and closed conformations of cTnC's hydrophobic cleft play a significant role in tuning the Ca 2+ sensitivity of the heart.

  20. Diagnosis of unstable angina pectoris has declined markedly with the advent of more sensitive troponin assays.

    Science.gov (United States)

    D'Souza, Maria; Sarkisian, Laura; Saaby, Lotte; Poulsen, Tina S; Gerke, Oke; Larsen, Torben B; Diederichsen, Axel C P; Jangaard, Nikolaj; Diederichsen, Søren Z; Hosbond, Susanne; Hove, Jens; Thygesen, Kristian; Mickley, Hans

    2015-08-01

    Since the arrival of the universal definition of myocardial infarction more sensitive troponin assays have been developed. How these occurrences have influenced the proportions and clinical features of the components of acute coronary syndrome have not been studied prospectively in unselected hospital patients. During 2010 we evaluated all patients in whom cardiac troponin I had been measured at a single university hospital. The diagnosis of acute myocardial infarction (ST-elevation myocardial infarction [STEMI] or non-ST-elevation myocardial infarction [NSTEMI]) was established in cases of a rise and/or fall of cardiac troponin I together with cardiac ischemic features. Patients with unstable chest discomfort and cardiac troponin I values below the decision limit of myocardial infarction were diagnosed as having unstable angina pectoris. The definition of acute coronary syndrome included unstable angina pectoris, NSTEMI, and STEMI. Mortality data were obtained from the Danish Civil Personal Registration System. Of 3762 consecutive patients, 516 had acute coronary syndrome. Unstable angina pectoris was present in 7%, NSTEMI in 67%, and STEMI in 26%. The NSTEMI patients were older, more frequently women, and had more comorbidities than patients with unstable angina pectoris and STEMI. At median follow-up of 3.2 years 195 patients had died: 14% of unstable angina pectoris, 45% of NSTEMI, and 25% of STEMI patients. Age-adjusted log-rank statistics revealed differences in mortality: NSTEMI vs unstable angina pectoris (P = .0091) and NSTEMI vs STEMI (P = .0045). The application of the universal definition together with the use of a contemporary troponin assay seems to have reduced the proportion of patients with unstable angina pectoris to the benefit of patients with NSTEMI. Despite this, NSTEMI patients have a sustained higher mortality than patients with STEMI. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. The clinical utility of lipid profile and positive troponin in predicting future cardiac events

    Directory of Open Access Journals (Sweden)

    Arun Kumar

    2012-02-01

    Full Text Available Objective: To study the usefulness of traditional lipid profile levels in screening subjects who had developed chest pain due to cardiac event as indicated by a positive troponin I (TnI test. Methods: In this retrospective study data of the 740 patients presented to the emergency department with symptoms of cardiac ischemia that underwent both troponin and lipid profiles tests were compared with the lipid profiles of 411 normal healthy subjects (controls. The troponin was detected qualitatively when a specimen contains TnI above the 99th percentile (TnI >0.5 ng/ mL. The total cholesterol (TC, high density lipoproteins (HDL, very low density lipoproteins (VLDL, and triacyl glycerol (TG levels were also analyzed and low density lipoprotein level (LDL was calculated using Friedewald ’s formula. Results: Patients with chest pain and positive troponin test (with confirmed cardiac event were found to have significantly elevated levels of TC, TG, LDL and significantly reduced HDL levels when compared to the patients who experienced only chest pain (negative troponin and healthy controls. Conclusions: Traditional lipid profile levels still can be used in screening populations to identify the subjects with high risk of developing cardiac event which is identified by highly sensitive and specific positive troponin test.

  2. Detected troponin elevation is associated with high early mortality after lung resection for cancer

    Directory of Open Access Journals (Sweden)

    Van Tornout Fillip

    2006-10-01

    Full Text Available Abstract Background Myocardial infarction can be difficult to diagnose after lung surgery. As recent diagnostic criteria emphasize serum cardiac markers (in particular serum troponin we set out to evaluate its clinical utility and to establish the long term prognostic impact of detected abnormal postoperative troponin levels after lung resection. Methods We studied a historic cohort of patients with primary lung cancer who underwent intended surgical resection. Patients were grouped according to known postoperative troponin status and survival calculated by Kaplan Meier method and compared using log rank. Parametric survival analysis was used to ascertain independent predictors of mortality. Results From 2001 to 2004, a total of 207 patients underwent lung resection for primary lung cancer of which 14 (7% were identified with elevated serum troponin levels within 30 days of surgery, with 9 (64% having classical features of myocardial infarction. The median time to follow up (interquartile range was 22 (1 to 52 months, and the one and five year survival probabilities (95% CI for patients without and with postoperative troponin elevation were 92% (85 to 96 versus 60% (31 to 80 and 61% (51 to 71 versus 18% (3 to 43 respectively (p T stage and postoperative troponin elevation remained independent predictors of mortality in the final multivariable model. The acceleration factor for death of elevated serum troponin after adjusting for tumour stage was 9.19 (95% CI 3.75 to 22.54. Conclusion Patients with detected serum troponin elevation are at high risk of early mortality with or without symptoms of myocardial infarction after lung resection.

  3. Assessment of the 2016 National Institute for Health and Care Excellence high-sensitivity troponin rule-out strategy

    Science.gov (United States)

    Greenslade, Jaimi; Cullen, Louise; Than, Martin; Kendall, Jason; Body, Richard; Parsonage, William A; Khattab, Ahmed

    2018-01-01

    Objective We aimed to evaluate the limit of detection of high-sensitivity troponin (hs-cTn) and Thrombolysis In Myocardial Infarction (TIMI) score combination rule-out strategy suggested within the 2016 National Institute for Health and Care Excellence (NICE) Chest Pain of Recent Onset guidelines and establish the optimal TIMI score threshold for clinical use. Methods A pooled analysis of adult patients presenting to the emergency department with chest pain and a non-ischaemic ECG, recruited into six prospective studies, from Australia, New Zealand and the UK. We evaluated the sensitivity of TIMI score thresholds from 0 to 2 alongside hs-cTnT or hs-cTnI for the primary outcome of major adverse cardiac events within 30 days. Results Data were available for 3159 patients for hs-cTnT and 4532 for hs-cTnI, of these 376 (11.9%) and 445 (9.8%) had major adverse cardiac events, respectively. Using a TIMI score of 0, the sensitivity for the primary outcome was 99.5% (95% CI 98.1% to 99.9%) alongside hs-cTnT and 98.9% (97.4% to 99.6%)%) alongside hs-cTnI, identifying 17.9% and 21.0% of patients as low risk, respectively. For a TIMI score ≤1 sensitivity was 98.9% (97.3% to 99.7%)%) alongside hs-cTnT and 98.4% (96.8% to 99.4%)%) alongside hs-cTnI, identifying 28.1% and 35.7% as low risk, respectively. For TIMI≤2, meta-sensitivity was <98% with either assay. Conclusions Our findings support the rule-out strategy suggested by NICE. The TIMI score threshold suggested for clinical use is 0. The proportion of patients identified as low risk (18%–21%) and suitable for early discharge using this threshold may be sufficient to encourage change of practice. Trial registration numbers ADAPT observational study/IMPACT intervention trial ACTRN12611001069943. ADAPT-ADP randomised controlled trial ACTRN12610000766011. EDACS-ADP randomised controlled trial ACTRN12613000745741. TRUST observational study ISRCTN no. 21109279. PMID:28864718

  4. Troponin and exercise.

    Science.gov (United States)

    Gresslien, T; Agewall, S

    2016-10-15

    Cardiac troponins are the preferred biomarkers in diagnostic of myocardial infarction, but these markers also can rise in response to exercise. Multiple studies have assessed troponins post-exercise, but the results have varied and there have been disagreements about the mechanism of troponin release. The aim of this paper was to review the literature, and to consider factors and mechanisms regarding exercise-induced increase of troponin. 145 studies were found after a search in pubmed and inclusion of additional articles found in the reference list of the first articles. Results showed that troponin rises in 0-100% of subjects after prolonged heavy exercise like marathon, but also after short-term and intermittent exercise like 30min of running and basketball. The variation can be due to factors like intensity, age, training experience, variation in sample size, blood sample timing and troponin assay. The pattern of troponin level post-exercise corresponds to release from the cytosolic compartment of cardiomyocytes. Increased membrane permeability might be caused by production of reactive oxygen species or alterations in calcium, pH, glucose/fat metabolism or in communication between integrins. Other suggested mechanisms are increased cardiovascular stress, inflammation, vasculitis, release of troponin degradation products in "blebs", dehydration, impaired renal clearance and expression of cardiac troponin in skeletal muscle. It can be concluded that both heavy and light exercise may cause elevated troponin, which have to be considered when patient are suspected to have a myocardial infarction. Several factors probably influence post-exercise levels of troponin, but the mechanism of release is most likely physiologic. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Combined measurement of copeptin, high-sensitivity troponin T, and N-terminal proBNP improves the identification of patients at risk of cardiovascular death

    DEFF Research Database (Denmark)

    Alehagen, Urban; Dahlström, Ulf; Carstensen, John

    2012-01-01

    and all mortality was registered. Cardiovascular mortality was evaluated using Kaplan–Meier plots and multivariate Cox proportional hazard regression analyses. Results: Copeptin, HS-TnT, and NT-proBNP measurements provided independent prognostic information in a multivariate setting over 5 years (hazard......Objectives: A multimarker strategy for the handling of patients with heart failure has been suggested in the literature. Therefore, the potential prognostic relevance of combined copeptin, high-sensitivity troponin T (HS-TnT), and N-terminal proBNP (NT-proBNP) measurement in plasma from elderly...... patients with symptoms of heart failure was evaluated. Methods: This study included 470 elderly patients (mean age 73 years) from a rural municipality with symptoms of heart failure. Clinical examination, echocardiography, and biomarker measurements were performed. All patients were followed for 13 years...

  6. Troponin and anti-troponin autoantibody levels in patients with ventricular noncompaction.

    Directory of Open Access Journals (Sweden)

    Hatice Betül Erer

    Full Text Available Ventricular hypertrabeculation/noncompaction is a morphologic and functional anomaly of myocardium characterized by prominent trabeculae accompanied by deep recessus. Dilated cardiomyopathy with left ventricular failure is observed in these patients, while the cause or pathophysiologic nature of this complication is not known. Anti-troponin antibodies are formed against circulating cardiac troponins after an acute coronary event or conditions associated with chronic myocyte necrosis, such as dilated cardiomyopathy. In present study, we aimed to investigate cardiac troponins and anti troponin autoantibodies in ventricular noncompaction/hypertrabeculation patients with/without reduced ejection fraction. A total of 50 patients with ventricular noncompaction and 23 healthy volunteers were included in this study. Noncompaction/hypertrabeculation was diagnosed with two-dimensional echocardiography using appropriate criteria. Depending on ejection fraction, patients were grouped into noncompaction with preserved EF (LVEF >50%, n = 24 and noncompaction with reduced EF (LVEF <35%, n = 26 groups. Troponin I, troponin T, anti-troponin I IgM and anti-troponin T IgM were measured with sandwich immunoassay method using a commercially available kit. Patients with noncompaction had significantly higher troponin I (28.98±9.21 ng/ml in NCNE group and 28.11±10.42 ng/ml in NCLE group, troponin T (22.17±6.97 pg/ml in NCNE group and 22.78±7.76 pg/ml in NCLE group and antitroponin I IgM (1.92±0.43 µg/ml in NCNE group and 1.79±0.36 µg/ml in NCLE group levels compared to control group, while antitroponin T IgM and IgG were only elevated in patients with noncompaction and reduced EF (15.81±6.52 µg/ml for IgM and 16.46±6.25 µg/ml for IgG. Elevated cardiac troponins and anti-troponin I autoantibodies were observed in patients with noncompaction preceding the decline in systolic function and could indicate ongoing myocardial damage in these patients.

  7. Troponin and Anti-Troponin Autoantibody Levels in Patients with Ventricular Noncompaction

    Science.gov (United States)

    Erer, Hatice Betül; Güvenç, Tolga Sinan; Kemik, Ahu Sarbay; Yılmaz, Hale Yaka; Kul, Şeref; Altay, Servet; Sayar, Nurten; Kaya, Yüksel; Eren, Mehmet

    2013-01-01

    Ventricular hypertrabeculation/noncompaction is a morphologic and functional anomaly of myocardium characterized by prominent trabeculae accompanied by deep recessus. Dilated cardiomyopathy with left ventricular failure is observed in these patients, while the cause or pathophysiologic nature of this complication is not known. Anti-troponin antibodies are formed against circulating cardiac troponins after an acute coronary event or conditions associated with chronic myocyte necrosis, such as dilated cardiomyopathy. In present study, we aimed to investigate cardiac troponins and anti troponin autoantibodies in ventricular noncompaction/hypertrabeculation patients with/without reduced ejection fraction. A total of 50 patients with ventricular noncompaction and 23 healthy volunteers were included in this study. Noncompaction/hypertrabeculation was diagnosed with two-dimensional echocardiography using appropriate criteria. Depending on ejection fraction, patients were grouped into noncompaction with preserved EF (LVEF >50%, n = 24) and noncompaction with reduced EF (LVEF <35%, n = 26) groups. Troponin I, troponin T, anti-troponin I IgM and anti-troponin T IgM were measured with sandwich immunoassay method using a commercially available kit. Patients with noncompaction had significantly higher troponin I (28.98±9.21 ng/ml in NCNE group and 28.11±10.42 ng/ml in NCLE group), troponin T (22.17±6.97 pg/ml in NCNE group and 22.78±7.76 pg/ml in NCLE group) and antitroponin I IgM (1.92±0.43 µg/ml in NCNE group and 1.79±0.36 µg/ml in NCLE group) levels compared to control group, while antitroponin T IgM and IgG were only elevated in patients with noncompaction and reduced EF (15.81±6.52 µg/ml for IgM and 16.46±6.25 µg/ml for IgG). Elevated cardiac troponins and anti-troponin I autoantibodies were observed in patients with noncompaction preceding the decline in systolic function and could indicate ongoing myocardial damage in these patients. PMID:23469039

  8. Influence of population selection on the 99th percentile reference value for cardiac troponin assays.

    Science.gov (United States)

    Collinson, Paul O; Heung, Yen Ming; Gaze, David; Boa, Frances; Senior, Roxy; Christenson, Robert; Apple, Fred S

    2012-01-01

    We sought to determine the effect of patient selection on the 99th reference percentile of 2 sensitive and 1 high-sensitivity (hs) cardiac troponin assays in a well-defined reference population. Individuals>45 years old were randomly selected from 7 representative local community practices. Detailed information regarding the participants was collected via questionnaires. The healthy reference population was defined as individuals who had no history of vascular disease, hypertension, or heavy alcohol intake; were not receiving cardiac medication; and had blood pressure60 mL·min(-1)·(1.73 m2)(-1), and normal cardiac function according to results of echocardiography. Samples were stored at -70 °C until analysis for cardiac troponin I (cTnI) and cardiac troponin T (cTnT) and N-terminal pro-B-type natriuretic peptide. Application of progressively more stringent population selection strategies to the initial baseline population of 545 participants until the only individuals who remained were completely healthy according to the study criteria reduced the number of outliers seen and led to a progressive decrease in the 99th-percentile value obtained for the Roche hs-cTnT assay and the sensitive Beckman cTnI assay but not for the sensitive Siemens Ultra cTnI assay. Furthermore, a sex difference found in the baseline population for the hs-cTnT (P=0.0018) and Beckman cTnI assays (Pstrategy significantly influenced the 99th percentile reference values determined for troponin assays and the observed sex differences in troponin concentrations.

  9. NT-proBNP and troponin T levels differ after haemodialysis with a low versus high flux membrane

    OpenAIRE

    Laveborn, Emilie; Lindmark, Krister; Skagerlind, Malin; Stegmayr, Bernd

    2015-01-01

    BACKGROUND: Brain natriuretic peptide (BNP), N-terminal-proBNP (NT-proBNP), and high sensitive cardiac troponin T (TnT) are markers that are elevated in chronic kidney disease and correlate with increased risk of mortality. Data are conflicting on the effect of biomarker levels by hemodialysis (HD).Our aim was to clarify to what extent HD with low-flux (LF) versus high-flux (HF) membranes affects the plasma levels of BNP, NT-proBNP, and TnT. METHODS AND MATERIALS: 31 HD patients were included...

  10. Plasma Levels of High Sensitivity Cardiac Troponin T in Adults with Repaired Tetralogy of Fallot

    Science.gov (United States)

    Lai, Clare T. M.; Wong, Sophia J.; Ip, Janice J. K.; Wong, Wai-keung; Tsang, Kwong-cheong; Lam, Wendy W. M.; Cheung, Yiu-fai

    2015-01-01

    Detectable low circulating level of cardiac troponin T (cTnT) may reflect subclinical myocardial injury. We tested the hypothesis that circulating levels of hs-cTnT are altered in adults with repaired tetralogy of Fallot (TOF) and associated with ventricular volume load and function. Eighty-eight TOF patients and 48 controls were studied. Plasma hs-cTnT levels were determined using a highly sensitive assay (hs-cTnT). The right (RV) and left ventricular (LV) volumes and ejection fraction (EF) were measured using 3D echocardiography and, in 52 patients, cardiac magnetic resonance (CMR). The median (interquartile range) for male and female patients were 4.87 (3.83–6.62) ng/L and 3.11 (1.00–3.87) ng/L, respectively. Thirty percent of female but none of the male patients had increased hs-cTnT levels. Female patients with elevated hs-cTnT levels, compared to those without, had greater RV end-diastolic and end-systolic volumes and LV systolic dyssynchrony index (all p < 0.05). For patient cohort only, hs-cTnT levels correlated positively with CMR-derived RV end-diastolic volume and negatively with echocardiography-derived LV and RV EF (all p < 0.05). Multiple linear regression identified sex and RV EF as significant correlates of log-transformed hs-cTnT levels. Increased hs-cTnT levels occur in 30% of female patients after TOF repair, and are associated with greater RV volumes and worse RV EF. PMID:26360613

  11. Validation of the (Troponin-only) Manchester ACS decision aid with a contemporary cardiac troponin I assay.

    Science.gov (United States)

    Va Den Berg, Patricia; Burrows, Gillian; Lewis, Philip; Carley, Simon; Body, Richard

    2018-04-01

    The Manchester Acute Coronary Syndromes (MACS) decision aid can 'rules in' and 'rule out' acute coronary syndromes (ACS) by combining a patient's symptoms with the results of a single blood test taken at the time of arrival in the Emergency Department (ED). The original model (MACS) included two biomarkers: high sensitivity cardiac troponin T (hs-cTnT) and heart-type fatty acid binding protein (h-FABP). A refined model without h-FABP was found to have comparable sensitivity but greater specificity. We sought to validate MACS and T-MACS using the contemporary Siemens Advia Centaur cardiac troponin I assay to increase usability in practice. This is a secondary analysis from prospective diagnostic cohort study at Stepping Hill Hospital, United Kingdom. Patients presenting with chest pain of suspected cardiac nature warranting rule out for ACS were included. All patients underwent hs-cTnT testing at least 12h after peak symptoms. The primary outcome was a diagnosis of ACS, defined as either prevalent acute myocardial infarction (AMI) or incident major adverse cardiac events (death, AMI or coronary revascularization) within 30days. Of 405 included patients, 76 (18.8%) had ACS. MACS and T-MACS had similar C-statistics (0.94 for each, p=0.36) and sensitivity (difference 1.3%, 95% CI -1.3 to 3.9%, p=1.00) but T-MACS had significantly greater specificity (difference 16.7%, 95% CI 14.6-18.9%, p<0.0001). T-MACS and MACS would have allowed 36.3% and 22.5% patients to be immediately discharged respectively. Of patients classified as 'very low risk', none had ACS when MACS was used compared to one (0.7%) with T-MACS. Both MACS and T-MACS effectively ruled out ACS even with a contemporary troponin I assay and could be used to reduce unnecessary hospital admissions. Copyright © 2017. Published by Elsevier Inc.

  12. Cross-sectional study of high-sensitivity cardiac troponins T and I in a hospital and community outpatient setting.

    Science.gov (United States)

    Potter, Julia M; Simpson, Aaron J; Kerrigan, Jennifer; Southcott, Emma; Salib, Marie M; Koerbin, Gus; Hickman, Peter E

    2017-02-01

    Cardiac troponins are specific for the heart, but not for the acute coronary syndrome. We wanted to assess how common elevated cardiac troponin concentrations were, in a population with significant non-cardiac disease. We measured both hs-cTnT and hs-cTnI on all samples submitted to the laboratory during one 24h period, and assessed the magnitude of the cTn concentration with the location and severity of disease of the patient. Community patients and patients from the maternity ward had the lowest cTn concentrations with results above the 99th percentile being only 0-2% of the total. As expected, the highest proportion of results >99th percentile came from Coronary Care and Intensive Care. However, substantial numbers of persons on Medical and Surgical wards, without a primary diagnosis of cardiac disease, also had cTn >99th percentile. Particularly for cTnT, there was a highly significant odds ratio predicting mortality when results above and below the 99th percentile were compared. Significant illnesses apart from the acute coronary syndrome are important causes of a rise in cTn to above the 99th percentile, and appear to reflect the total body burden of disease. Even when the high hs-cTn concentration is not due to the acute coronary syndrome, there is a significant association with all-cause mortality. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Sex differences of troponin test performance in chest pain patients.

    Science.gov (United States)

    Slagman, Anna; Searle, Julia; Vollert, Jörn O; Storchmann, Harald; Büschenfelde, Dirk Meyer Zum; von Recum, Johannes; Vlasny, Daniela; Ale-Abaei, Angela; Koch, Matthias; Müller, Christian; Müller, Reinhold; Somasundaram, Rajan; Möckel, Martin

    2015-01-01

    Current guidelines recommend troponin as the preferred biomarker to diagnose acute myocardial infarction (AMI) irrespective of the patient's sex. Recent reports have shown that sex-specific cut-offs should be considered but studies investigating sex-differences in the diagnostic accuracy of cardiac troponins are sparse. To evaluate whether the diagnostic performance of cardiac troponin at admission (cTn) under routine conditions is influenced by patient's sex. Between 15th of February 2009 and 15th of February 2010, women (n=1648) and men (n=2305) who presented to the emergency department with chest pain (n=3954) were enrolled. The diagnostic performance of the routine, contemporary sensitive cTn assays (TnI; Stratus® CS, Siemens and TnT; Roche Diagnostics) at baseline for the diagnosis of non-ST-elevation myocardial infarction (NSTEMI) was analyzed. NSTEMI was diagnosed in 7.3% (n=287) of all patients. Men were more likely to be diagnosed with NSTEMI (8.8%; n=202) as compared to women (5.2%; n=85; psex, with a lower sensitivity and NPV in women. The definition and implementation of sex-specific cut-off values for cTn into clinical routine seems to be highly recommendable. Copyright © 2015. Published by Elsevier Ireland Ltd.

  14. Absolute and relative kinetic changes of high-sensitivity cardiac troponin T in acute coronary syndrome and in patients with increased troponin in the absence of acute coronary syndrome.

    Science.gov (United States)

    Mueller, Matthias; Biener, Moritz; Vafaie, Mehrshad; Doerr, Susanne; Keller, Till; Blankenberg, Stefan; Katus, Hugo A; Giannitsis, Evangelos

    2012-01-01

    We evaluated kinetic changes of high-sensitivity cardiac troponin T (hs-cTnT) in patients with acute coronary syndrome (ACS) and patients with hs-cTnT increases not due to ACS to rule in or rule out non-ST-segment elevation myocardial infarction (STEMI). hs-cTnT was measured serially in consecutive patients presenting to the emergency department. Patients with ACS who had at least 2 hs-cTnT measurements within 6 h and non-ACS patients with hs-cTnT concentrations above the 99th percentile value (14 ng/L) were enrolled to compare absolute and relative kinetic changes of hs-cTnT. For discrimination of non-STEMI (n=165) in the entire study population (n=784), the absolute δ change with the ROC-optimized value of 9.2 ng/L yielded an area under the curve of 0.898 and was superior to all relative δ changes (Prise or fall of at least 9.2 ng/L in the entire study population and 6.9 ng/L in selected ACS patients seems adequate to rule-out non-STEMI. However, δ-values are useful to rule-in non-STEMI only in a specific ACS population.

  15. Serial Sampling of High-Sensitivity Cardiac Troponin T May Not Be Required for Prediction of Acute Myocardial Infarction Diagnosis in Chest Pain Patients with Highly Abnormal Concentrations at Presentation.

    Science.gov (United States)

    Mueller-Hennessen, Matthias; Mueller, Christian; Giannitsis, Evangelos; Biener, Moritz; Vafaie, Mehrshad; deFilippi, Christopher R; Christ, Michael; Ordóñez-Llanos, Jorge; Panteghini, Mauro; Plebani, Mario; Verschuren, Franck; Melki, Dina; French, John K; Christenson, Robert H; Body, Richard; McCord, James; Dinkel, Carina; Katus, Hugo A; Lindahl, Bertil

    2017-02-01

    Guidelines for diagnosing acute myocardial infarction (AMI) recommend adding kinetic changes to the initial cardiac troponin (cTn) blood concentration to improve AMI diagnosis. We hypothesized that kinetic changes may not be required in patients presenting with highly abnormal cTn. Patients presenting with suspected AMI to the emergency department were enrolled in a prospective diagnostic study. We assessed the positive predictive value (PPV) of initial high-sensitivity cardiac troponin T (hs-cTnT) blood concentrations alone and in combination with kinetic changes for AMI. Predefined relative changes (δ change of ≥20%) and absolute changes (Δ change ≥9.2 ng/L) within different time intervals (1 h, 2 h, and 4-14 h after presentation) were assessed. The final diagnosis was adjudicated by 2 independent cardiologists. Among 1282 patients, 213 (16.6%) patients had a final diagnosis of AMI. For AMI prediction, PPVs increased from 48.8% for an initial hs-cTnT >14 ng/L to 87.2% for >60 ng/L, whereas PPVs remained unchanged for higher hs-cTnT concentrations at baseline (87.1% for both >80 ng/L and >100 ng/L). With addition of 20% relative Δ change, PPVs were not further improved in patients with baseline hs-cTnT >80 ng/L using the 1-h (84.0%) and 2-h (88.9%) intervals, and only minimally when extending the interval to 4-14 h (91.2% for >80 ng/L and 90.4% for >100 ng/L, respectively). Similar findings were observed when applying absolute changes. In chest pain patients with highly abnormal hs-cTnT concentrations at presentation, subsequent blood draws may not be required, as they do not provide incremental diagnostic value for prediction of AMI diagnosis. © 2016 American Association for Clinical Chemistry.

  16. Time to shift from contemporary to high-sensitivity cardiac troponin in diagnosis of acute coronary syndromes

    Directory of Open Access Journals (Sweden)

    Jamshed J. Dalal

    2016-11-01

    Training and displaying the clinical algorithm depicting the role of hs-TnI assay in acute cardiac care units and in EDs are an efficient way to deliver the new standard of care to patients. Compared with contemporary troponin assays, the hs-cTn assay accelerates the diagnostic pathway to 0–1 h, thus reducing the time for diagnosis of NSTEMI and hence, its management.

  17. Elevated Cardiac Troponin T in Patients With Skeletal Myopathies.

    Science.gov (United States)

    Schmid, Johannes; Liesinger, Laura; Birner-Gruenberger, Ruth; Stojakovic, Tatjana; Scharnagl, Hubert; Dieplinger, Benjamin; Asslaber, Martin; Radl, Roman; Beer, Meinrad; Polacin, Malgorzata; Mair, Johannes; Szolar, Dieter; Berghold, Andrea; Quasthoff, Stefan; Binder, Josepha S; Rainer, Peter P

    2018-04-10

    Cardiac troponins are often elevated in patients with skeletal muscle disease who have no evidence of cardiac disease. The goal of this study was to characterize cardiac troponin concentrations in patients with myopathies and derive insights regarding the source of elevated troponin T measurements. Cardiac troponin T (cTnT) and cardiac troponin I (cTnI) concentrations were determined by using high sensitivity assays in 74 patients with hereditary and acquired skeletal myopathies. Patients underwent comprehensive cardiac evaluation, including 12-lead electrocardiogram, 24-h electrocardiogram, cardiac magnetic resonance imaging, and coronary artery computed tomography. cTnT and cTnI protein expression was determined in skeletal muscle samples of 9 patients and in control tissues derived from autopsy using antibodies that are used in commercial assays. Relevant Western blot bands were subjected to liquid chromatography tandem mass spectrometry for protein identification. Levels of cTnT (median: 24 ng/l; interquartile range: 11 to 54 ng/l) were elevated (>14 ng/l) in 68.9% of patients; cTnI was elevated (>26 ng/l) in 4.1% of patients. Serum cTnT levels significantly correlated with creatine kinase and myoglobin (r = 0.679 and 0.786, respectively; both p < 0.001). Based on cTnT serial testing, 30.1% would have fulfilled current rule-in criteria for myocardial infarction. Noncoronary cardiac disease was present in 23%. Using cTnT antibodies, positive bands were found in both diseased and healthy skeletal muscle at molecular weights approximately 5 kDa below cTnT. Liquid chromatography tandem mass spectrometry identified the presence of skeletal troponin T isoforms in these bands. Measured cTnT concentrations were chronically elevated in the majority of patients with skeletal myopathies, whereas cTnI elevation was rare. Our data indicate that cross-reaction of the cTnT immunoassay with skeletal muscle troponin isoforms was the likely cause. Copyright © 2018 The

  18. Cardiac troponin T: A sensitive and specific indicator of myocardial injury in patients with cerebrovascular stroke

    Directory of Open Access Journals (Sweden)

    Mohammed Amin

    2012-09-01

    Conclusions: Myocardial injury is not uncommon in patients with CVS. Silent ST-T wave changes and new resting SWMA are possible complications. We demonstrated highly significant correlation between positive troponin T and myocardial injury in these patients.

  19. Troponin elevation in patients with various tachycardias and normal epicardial coronaries

    Directory of Open Access Journals (Sweden)

    Yousuf Kanjwal

    2008-08-01

    Full Text Available Troponin elevation is usually synonymous with acute coronary syndrome (ACS. Although sensitive for ACS, the elevation of serum troponin, in the absence of clinical evidence of ischemia, should prompt a search for other etiologies of myocardial necrosis. In fact, elevated values of troponin are correlated with myocardial necrosis even though it does not discriminate the mechanism involved. We report a series of seven patients (age range 18-67 years, who presented with complaints of chest discomfort and were found to have regular supraventricular tachycardia (5 patients and one patient each with atrial fibrillation and ventricular tachycardia. All these patients had elevated troponin I and underwent coronary angiography that revealed normal epicardial coronary arteries. This is first case series in which all patients underwent coronary angiography and none of the patients was hemodynamically unstable at the time of presentation. Patients with elevated troponin due to conditions other than ACS can receive inappropriate and delayed definitive diagnosis and treatment.

  20. Falsely elevated troponin: rare occurrence or future problem

    Directory of Open Access Journals (Sweden)

    James Nguyen

    2016-12-01

    Full Text Available Introduction: Troponins are known to be released in response to cardiac damage and therefore are the biomarkers of choice for the early diagnosis of acute myocardial infarction (AMI, improving outcome in patients presenting with chest pain. However, false results can occur due to interference from other substances in the blood. Case: A 52-year-old male with a past medical history of alcohol abuse, hypertension, and coronary artery bypass graft at age 34 with normal stress test 2 years before presented to the emergency department (ED complaining of 1 day of non-exertional chest pain with radiation to the neck and left arm. His troponin was elevated to 5 ng/mL in two samples drawn 12 h apart, with normal CK-MB. Renal function was normal. Electrocardiogram (ECG showed normal sinus rhythm with no ST elevations or depressions. He underwent cardiac catheterization which showed no obstructive lesions. Five years later, he returned to the ED with abdominal pain and shortness of breath. Troponin was elevated and showed no signs of downtrend on repeat every 6 h. ECG was unchanged from 5 years before. He was discharged with a follow-up cardiac computed tomography (CT. Troponin was measured on the day of his scan and remained elevated; he was asymptomatic. Cardiac CT showed unremarkable coronaries and bypass grafts. Given persistently positive troponin in the setting of minimal to no symptoms, he was thought to have falsely elevated troponins. Centrifugation and 2:1 dilution of the sample resulted in the same general value, respectively. Rheumatoid factor and heterophile antibodies were negative. When his blood sample was sent to a different hospital utilizing a three-site immunoassay method, the value was found zero. Discussion: Cardiac troponins (cTn are structural proteins unique to the heart, not expressed outside of cardiac tissue and have high sensitivity and specificity for myocardial damage. Therefore, it is the test of choice for the diagnosis of

  1. External validation of heart-type fatty acid binding protein, high-sensitivity cardiac troponin, and electrocardiography as rule-out for acute myocardial infarction.

    Science.gov (United States)

    Van Hise, Christopher B; Greenslade, Jaimi H; Parsonage, William; Than, Martin; Young, Joanna; Cullen, Louise

    2018-02-01

    To externally validate a clinical decision rule incorporating heart fatty acid binding protein (h-FABP), high-sensitivity troponin (hs-cTn) and electrocardiogram (ECG) for the detection of acute myocardial infarction (AMI) on presentation to the Emergency Department. We also investigated whether this clinical decision rule improved identification of AMI over algorithms incorporating hs-cTn and ECG only. This study included data from 789 patients from the Brisbane ADAPT cohort and 441 patients from the Christchurch TIMI RCT cohort. The primary outcome was index AMI. Sensitivity, specificity, positive predictive value and negative predictive value were used to assess the diagnostic accuracy of the algorithms. 1230 patients were recruited, including 112 (9.1%) with AMI. The algorithm including h-FABP and hs-cTnT had 100% sensitivity and 32.4% specificity. The algorithm utilising h-FABP and hs-cTnI had similar sensitivity (99.1%) and higher specificity (43.4%). The hs-cTnI and hs-cTnT algorithms without h-FABP both had a sensitivity of 98.2%; a result that was not significantly different from either algorithm incorporating h-FABP. Specificity was higher for the hs-cTnI algorithm (68.1%) compared to the hs-cTnT algorithm (33.0%). The specificity of the algorithm incorporating hs-cTnI alone was also significantly higher than both of the algorithms incorporating h-FABP (p<0.01). For patients presenting to the Emergency Department with chest pain, an algorithm incorporating h-FABP, hs-cTn and ECG has high accuracy and can rule out up to 40% of patients. An algorithm incorporating only hs-cTn and ECG has similar sensitivity and may rule out a higher proportion of patients. Each of the algorithms can be used to safely identify patients as low risk for AMI on presentation to the Emergency Department. Copyright © 2017 The Canadian Society of Clinical Chemists. All rights reserved.

  2. N-terminal Pro-brain Natriuretic Peptide, High-sensitivity Troponin and Pulmonary Artery Clot Score as Predictors of Right Ventricular Dysfunction in Echocardiography.

    Science.gov (United States)

    Granér, Marit; Harjola, Veli-Pekka; Selander, Tuomas; Laiho, Mia K; Piilonen, Anneli; Raade, Merja; Mustonen, Pirjo

    2016-06-01

    We investigated the ability of cardiac biomarkers and total pulmonary artery (PA) clot score to predict right ventricular dysfunction (RVD) on admission and at seven-month follow-up in subjects with acute pulmonary embolism (APE). Sixty-three normotensive patients with APE were divided into two groups: patients with (n= 32, age 58±19 years) and without (n=31, age 55±16 years) echocardiographic RVD. Transthoracic echocardiography (TTE), N-terminal pro-brain natriuretic peptide (NT-proBNP), and high-sensitivity troponin T (hsTnT) were assessed upon arrival and repeated at seven months. Total PA clot score was determined on admission. The age- and sex dependent NT-proBNP on admission, on day 5, and at seven months exhibited the best sensitivity (admission 94%, day 5 100%, seven months 100%) and negative predictive value (NPV) (89%, 100%, 100%) for detecting RVD. Six patients (10%) had persistent RVD at seven months. Total PA clot score showed only low to moderate sensitivity (77%) and PPV (7%) for detection of RVD at seven months. Normal age- and sex dependent NT-proBNP on admission or measured five days later seems to be useful in exclusion of RVD at follow up. Total PA clot score shows only to be of modest benefit for predicting persistent RVD. Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  3. N-terminal pro-brain natriuretic peptide and high-sensitivity troponin T exhibit additive prognostic value for the outcome of critically ill patients.

    Science.gov (United States)

    Lenz, Max; Krychtiuk, Konstantin A; Goliasch, Georg; Distelmaier, Klaus; Wojta, Johann; Heinz, Gottfried; Speidl, Walter S

    2018-04-01

    Patients treated at medical intensive care units suffer from various pathologies and often present with elevated troponin T (TnT) and N-terminal pro-brain natriuretic peptide (NT-proBNP) levels. Both markers may reflect different forms of cardiac involvement in critical illness. Therefore, the aim of our study was to examine the synergistic prognostic potential of NT-proBNP and high-sensitivity TnT (hs)TnT in unselected critically ill patients. We included all consecutive patients admitted to our intensive care unit within one year, excluding those suffering from acute myocardial infarction or undergoing cardiac surgery and measured NT-proBNP and TnT plasma levels on the day of admission and 72 hours thereafter. Of the included 148 patients, 52% were male, mean age was of 64.2 ± 16.8 years and 30-day mortality was 33.2%. Non-survivors showed significantly higher NT-proBNP and TnT plasma levels as compared with survivors ( pvalue. This might be attributed to a difference in underlying pathomechanisms and an assessment of synergistic risk factors.

  4. Combining High Sensitivity Cardiac Troponin I and Cardiac Troponin T in the Early Diagnosis of Acute Myocardial Infarction.

    Science.gov (United States)

    van der Linden, Noreen; Wildi, Karin; Twerenbold, Raphael; Pickering, John W; Than, Martin; Cullen, Louise; Greenslade, Jaimi; Parsonage, William; Nestelberger, Thomas; Boeddinghaus, Jasper; Badertscher, Patrick; Rubini Giménez, Maria; Klinkenberg, Lieke J J; Bekers, Otto; Schöni, Aline; Keller, Dagmar I; Sabti, Zaid; Puelacher, Christian; Cupa, Janosch; Schumacher, Lukas; Kozhuharov, Nikola; Grimm, Karin; Shrestha, Samyut; Flores, Dayana; Freese, Michael; Stelzig, Claudia; Strebel, Ivo; Miró, Òscar; Rentsch, Katharina; Morawiec, Beata; Kawecki, Damian; Kloos, Wanda; Lohrmann, Jens; Richards, A Mark; Troughton, Richard; Pemberton, Christopher; Osswald, Stefan; van Dieijen-Visser, Marja P; Mingels, Alma M; Reichlin, Tobias; Meex, Steven J R; Mueller, Christian

    2018-04-24

    Background -Combining two signals of cardiomyocyte injury, cardiac troponin I (cTnI) and T (cTnT), might overcome some individual pathophysiological and analytical limitations and thereby increase diagnostic accuracy for acute myocardial infarction (AMI) with a single blood draw. We aimed to evaluate the diagnostic performance of combinations of high sensitivity (hs) cTnI and hs-cTnT for the early diagnosis of AMI. Methods -The diagnostic performance of combining hs-cTnI (Architect, Abbott) and hs-cTnT (Elecsys, Roche) concentrations (sum, product, ratio and a combination algorithm) obtained at the time of presentation was evaluated in a large multicenter diagnostic study of patients with suspected AMI. The optimal rule out and rule in thresholds were externally validated in a second large multicenter diagnostic study. The proportion of patients eligible for early rule out was compared with the ESC 0/1 and 0/3 hour algorithms. Results -Combining hs-cTnI and hs-cTnT concentrations did not consistently increase overall diagnostic accuracy as compared with the individual isoforms. However, the combination improved the proportion of patients meeting criteria for very early rule-out. With the ESC 2015 guideline recommended algorithms and cut-offs, the proportion meeting rule out criteria after the baseline blood sampling was limited (6-24%) and assay dependent. Application of optimized cut-off values using the sum (9 ng/L) and product (18 ng2/L2) of hs-cTnI and hs-cTnT concentrations led to an increase in the proportion ruled-out after a single blood draw to 34-41% in the original (sum: negative predictive value (NPV) 100% (95%CI: 99.5-100%); product: NPV 100% (95%CI: 99.5-100%) and in the validation cohort (sum: NPV 99.6% (95%CI: 99.0-99.9%); product: NPV 99.4% (95%CI: 98.8-99.8%). The use of a combination algorithm (hs-cTnI <4 ng/L and hs-cTnT <9 ng/L) showed comparable results for rule out (40-43% ruled out; NPV original cohort 99.9% (95%CI: 99.2-100%); NPV

  5. Progression in sensing cardiac troponin biomarker charge transductions on semiconducting nanomaterials

    Energy Technology Data Exchange (ETDEWEB)

    Fathil, M.F.M., E-mail: faris.fathil@gmail.com [Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis, 01000, Kangar, Perlis (Malaysia); Md Arshad, M.K., E-mail: mohd.khairuddin@unimap.edu.my [Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis, 01000, Kangar, Perlis (Malaysia); School of Microelectronic Engineering, Universiti Malaysia Perlis, 01000, Kangar, Perlis (Malaysia); Ruslinda, A.R., E-mail: ruslinda@unimap.edu.my [Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis, 01000, Kangar, Perlis (Malaysia); Nuzaihan, M.N.M., E-mail: m.nuzaihan@unimap.edu.my [Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis, 01000, Kangar, Perlis (Malaysia); Gopinath, Subash C.B., E-mail: subash@unimap.edu.my [Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis, 01000, Kangar, Perlis (Malaysia); School of Bioprocess Engineering, Universiti Malaysia Perlis, 02600, Arau, Perlis (Malaysia); Adzhri, R., E-mail: adzhri@gmail.com [Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis, 01000, Kangar, Perlis (Malaysia); Hashim, U., E-mail: uda@unimap.edu.my [Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis, 01000, Kangar, Perlis (Malaysia); School of Microelectronic Engineering, Universiti Malaysia Perlis, 01000, Kangar, Perlis (Malaysia)

    2016-09-07

    A real-time ability to interpret the interaction between targeted biomolecules and the surface of semiconductors (metal transducers) into readable electrical signals, without biomolecular modification involving fluorescence dyes, redox enzymes, and radioactive labels, created by label-free biosensors has been extensively researched. Field-effect transistor (FET)- and capacitor-based biosensors are among the diverse electrical charge biosensing architectures that have drawn much attention for having charge transduction; thus, enabling the early and rapid diagnosis of the appropriate cardiac biomarkers at lower concentrations. These semiconducting material-based transducers are very suitable to be integrated with portable electronic devices for future online collection, transmission, reception, analysis, and reporting. This overview elucidates and clarifies two major electrical label-free systems (FET- and capacitor-based biosensors) with cardiac troponin (cTn) biomarker-mediated charge transduction for acute myocardial infarction (AMI) diagnosis. Advances in these systems are highlighted by their progression in bridging the laboratory and industry; the foremost technologies have made the transition from benchtop to bedside and beyond. - Highlights: • The progression of cardiac troponin detection from past to future are presented. • Electrical label-free biosensors for cardiac troponin are discussed. • The discussion focused on field-effect transistor-and capacitor-based devices. • Surface functionalization, sensitivity, and innovation of devices are highlighted. • They presented high sensitivity and specificity of real-time AMI determination.

  6. Early diagnosis of myocardial infarction using absolute and relative changes in cardiac troponin concentrations.

    Science.gov (United States)

    Irfan, Affan; Reichlin, Tobias; Twerenbold, Raphael; Meister, Marc; Moehring, Berit; Wildi, Karin; Bassetti, Stefano; Zellweger, Christa; Gimenez, Maria Rubini; Hoeller, Rebeca; Murray, Karsten; Sou, Seoung Mann; Mueller, Mira; Mosimann, Tamina; Reiter, Miriam; Haaf, Philip; Ziller, Ronny; Freidank, Heike; Osswald, Stefan; Mueller, Christian

    2013-09-01

    Absolute changes in high-sensitivity cardiac troponin T (hs-cTnT) seem to have higher diagnostic accuracy in the early diagnosis of acute myocardial infarction compared with relative changes. It is unknown whether the same applies to high-sensitivity cardiac troponin I (hs-cTnI) assays and whether the combination of absolute and relative change might further increase accuracy. In a prospective, international multicenter study, high-sensitivity cardiac troponin (hs-cTn) was measured with 3 novel assays (hs-cTnT, Roche Diagnostics Corp, Indianapolis, Ind; hs-cTnI, Beckman Coulter Inc, Brea, Calif; hs-cTnI, Siemens, Munich, Germany) in a blinded fashion at presentation and after 1 and 2 hours in a blinded fashion in 830 unselected patients with suspected acute myocardial infarction. The final diagnosis was adjudicated by 2 independent cardiologists. The area under the receiver operating characteristic curve for diagnosing acute myocardial infarction was significantly higher for 1- and 2-hour absolute versus relative hs-cTn changes for all 3 assays (P Siemens, 0.96 [95% CI, 0.93-0.99]) were high and provided some benefit compared with the use of absolute change alone for hs-cTnT, but not for the hs-cTnI assays. Reclassification analysis confirmed the superiority of absolute changes versus relative changes. Absolute changes seem to be the preferred metrics for both hs-cTnT and hs-cTnI in the early diagnosis of acute myocardial infarction. The combination of absolute and relative changes provides a small added value for hs-cTnT, but not for hs-cTnI. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. The structure of the muscle protein complex 4Ca2+ ·troponin C · troponin

    International Nuclear Information System (INIS)

    Olah, G.A.; Trewhella, J.

    1994-01-01

    Analysis of scattering data based on a Monte Carlo integration method was used to 2+ obtain a low resolution model of the 4Ca 2+ circ troponin C circ troponin I complex. This modeling method allows rapid testing of plausible structures where the best fit model can be ascertained by a comparison between model structure scattering profiles and measured scattering data. In the best fit model, troponin I appears as a spiral structure 2+ that wraps around 4Ca 2+ circ troponin C which adopts an extended dumbbell conformation similar to that observed in the crystal structures of troponin C. The Monte Carlo modeling method can be applied to other biological systems in which detailed structural information is lacking

  8. Serum cardiac troponin I and cardiac troponin T concentrations in dogs with gastric dilatation-volvulus.

    Science.gov (United States)

    Schober, Karsten E; Cornand, Corinna; Kirbach, Babett; Aupperle, Heike; Oechtering, Gerhard

    2002-08-01

    To determine whether serum concentrations of cardiac troponin I (cTnI) and cardiac troponin T (cTnT) are increased in dogs with gastric dilatationvolvulus (GDV) and whether concentrations correlate with severity of ECG abnormalities or outcome. Prospective case series. 85 dogs with GDV. Serum cTnl and cTnT concentrations were measured 12 to 24, 48, 72, and 96 hours after surgery. Dogs were grouped on the basis of severity of ECG abnormalities and outcome. cTnl and cTnT were detected in serum from 74 (87%) and 43 (51%) dogs, respectively. Concentrations were significantly different among groups when dogs were grouped on the basis of severity of ECG abnormalities (none or mild vs moderate vs severe). Dogs that died (n = 16) had significantly higher serum cTnI (24.9 ng/ml) and cTnT (0.18 ng/ml) concentrations than did dogs that survived (2.05 and dogs with high serum cardiac troponin concentrations. Results indicate that concentrations of cTnI and cTnT suggestive of myocardial cell injury can commonly be found in serum from dogs with GDV and that serum cardiac troponin concentrations are associated with severity of ECG abnormalities and outcome.

  9. Relationship between Cardiac Troponin and Thrombo-Inflammatory Molecules in Prediction of Outcome after Acute Ischemic Stroke

    DEFF Research Database (Denmark)

    Csecsei, Peter; Pusch, Gabriella; Ezer, Erzsebet

    2018-01-01

    BACKGROUND: In patients with acute ischemic stroke (AIS) without cardiovascular complications, we investigated the association of serum concentration of cardiac troponin (high-sensitivity cardiac troponin T [hs-cTnT]) with thrombo-inflammatory markers. METHODS: Thirty-five patients with first......-ever AIS were prospectively examined. Serum hs-cTnT was measured 6 and 24 hours after stroke, whereas S100B, high-sensitivity C-reactive protein (hsCRP), soluble CD40 ligand, tissue plasminogen activator (tPA), monocyte chemoattractant protein-1 (MCP-1), and P-selectin were measured 6 and 72 hours after...... stroke. Severity of stroke was assessed by the National Institutes of Health Stroke Scale (NIHSS) on admission, 24 hours later, and at discharge. RESULTS: Concentration of MCP-1 at 6 hours was higher in the serum of patients with worsened NIHSS by 24 hours (P = .009). Concentration of hs-cTnT at both 6...

  10. Role of Admission Troponin-T and Serial Troponin-T Testing in Predicting Outcomes in Severe Sepsis and Septic Shock.

    Science.gov (United States)

    Vallabhajosyula, Saraschandra; Sakhuja, Ankit; Geske, Jeffrey B; Kumar, Mukesh; Poterucha, Joseph T; Kashyap, Rahul; Kashani, Kianoush; Jaffe, Allan S; Jentzer, Jacob C

    2017-09-09

    Troponin-T elevation is seen commonly in sepsis and septic shock patients admitted to the intensive care unit. We sought to evaluate the role of admission and serial troponin-T testing in the prognostication of these patients. This was a retrospective cohort study from 2007 to 2014 on patients admitted to the intensive care units at the Mayo Clinic with severe sepsis and septic shock. Elevated admission troponin-T and significant delta troponin-T were defined as ≥0.01 ng/mL and ≥0.03 ng/mL in 3 hours, respectively. The primary outcome was in-hospital mortality. Secondary outcomes included 1-year mortality and lengths of stay. During this 8-year period, 944 patients met the inclusion criteria with 845 (90%) having an admission troponin-T ≥0.01 ng/mL. Serial troponin-T values were available in 732 (78%) patients. Elevated admission troponin-T was associated with older age, higher baseline comorbidity, and severity of illness, whereas significant delta troponin-T was associated with higher severity of illness. Admission log 10 troponin-T was associated with unadjusted in-hospital (odds ratio 1.6; P =0.003) and 1-year mortality (odds ratio 1.3; P =0.04), but did not correlate with length of stay. Elevated delta troponin-T and log 10 delta troponin-T were not significantly associated with any of the primary or secondary outcomes. Admission log 10 troponin-T remained an independent predictor of in-hospital mortality (odds ratio 1.4; P =0.04) and 1-year survival (hazard ratio 1.3; P =0.008). In patients with sepsis and septic shock, elevated admission troponin-T was associated with higher short- and long-term mortality. Routine serial troponin-T testing did not add incremental prognostic value in these patients. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  11. A practical approach for the validation and clinical implementation of a high-sensitivity cardiac troponin I assay across a North American city

    Directory of Open Access Journals (Sweden)

    Peter A. Kavsak

    2015-04-01

    Full Text Available Objectives: Despite several publications on the analytical performance of high-sensitivity cardiac troponin (hs-cTn assays, there has been little information on how laboratories should validate and implement these assays into clinical service. Our study provides a practical approach for the validation and implementation of a hs-cTn assay across a large North American City. Design and methods: Validation for the Abbott ARCHITECT hs-cTnI assay (across 5 analyzers consisted of verification of limit of blank (LoB, precision (i.e., coefficient of variation; CV testing at the reported limit of detection (LoD and within and outside the 99th percentile, linearity testing, cTnI versus hs-cTnI patient comparison within and between analyzers (Passing and Bablok and non-parametric analyses. Education, clinical communications, and memorandums were issued in advance to inform all staff across the city as well as a selected reminder the day before live-date to important users. All hospitals switched to the hs-cTnI assay concurrently (the contemporary cTnI assay removed with laboratory staff instructed to repeat samples previously measured with the contemporary cTnI assay with the hs-cTnI assay only by physician request. Results: Across the 5 analyzers and 6 reagent packs the overall LoB was 0.6 ng/L (n=60 with a CV of 33% at an overall mean of 1.2 ng/L (n=60; reported LoD=1.0 ng/L, with linearity demonstrated from 45,005 ng/L to 1.1 ng/L. Precision testing with a normal patient-pool QC material (mean range across 5 analyzers was 3.9–4.4 ng/L yielded a range of CVs from 7% to 10% (within-run and CVs from 7% to 18% (between-run with the high patient-pool QC material (mean range across 5 analyzers was 29.6–36.3 ng/L yielding a range of CVs from 2% to 5% (within-run and CVs from 4% to 8% (between-run. There was agreement between hs-cTnI versus cTnI with the patient samples (slope ranges: 0.89–1.03; intercept ranges: 1.9–3

  12. Effect of antioxidant supplementation on exercise-induced cardiac troponin release in cyclists: a randomized trial.

    Science.gov (United States)

    Klinkenberg, Lieke J J; Res, Peter T; Haenen, Guido R; Bast, Aalt; van Loon, Luc J C; van Dieijen-Visser, Marja P; Meex, Steven J R

    2013-01-01

    Cardiac troponin is the biochemical gold standard to diagnose acute myocardial infarction. Interestingly however, elevated cardiac troponin concentrations are also frequently observed during and after endurance-type exercise. Oxidative stress associated with prolonged exercise has been proposed to contribute to cardiac troponin release. Therefore, the aim of this study was to assess the effect of 4 week astaxanthin supplementation (a potent cartenoid antioxidant) on antioxidant capacity and exercise-induced cardiac troponin release in cyclists. Thirty-two well-trained male cyclists (age 25±5, weight 73±7 kg, maximum O2 uptake 60±5 mL·kg(-1)·min(-1), Wmax 5.4±0.5 W·kg(-1); mean ± SD) were repeatedly subjected to a laboratory based standardized exercise protocol before and after 4 weeks of astaxanthin (20 mg/day), or placebo supplementation in a double-blind randomized manner. Blood samples were obtained at baseline, at 60 min of cycling and immediately post-exercise (≈ 120 min). The pre-supplementation cycling trial induced a significant rise of median cardiac troponin T concentrations from 3.2 (IQR 3.0-4.2) to 4.7 ng/L (IQR 3.7-6.7), immediately post-exercise (pexercise-induced cardiac troponin T release (p = 0.24), as measured by the incremental area under the curve. Furthermore, the elevation in basal plasma astaxanthin concentrations was not reflected in changes in antioxidant capacity markers (trolox equivalent antioxidant capacity, uric acid, and malondialdehyde). Markers of inflammation (high-sensitivity C-reactive protein) and exercise-induced skeletal muscle damage (creatine kinase) were equally unaffected by astaxanthin supplementation. Despite substantial increases in plasma astaxanthin concentrations, astaxanthin supplementation did not improve antioxidant capacity in well-trained cyclists. Accordingly, exercise-induced cardiac troponin T concentrations were not affected by astaxanthin supplementation. ClinicalTrials.gov NCT01241877.

  13. Operating characteristics of a qualitative troponin assay for the diagnosis of acute coronary syndrome.

    Science.gov (United States)

    Farsi, Davood; Pishbin, Elham; Abbasi, Saeed; Hafezimoghadam, Peyman; Fathi, Marzieh; Zare, Mohammad Amin

    2013-04-01

    The troponin I serum level is widely used in acute coronary syndrome patients for their classification. The qualitative assay is faster and more available than the quantitative assay. The objective was to determine the operating characteristics of a qualitative troponin I assay compared with a quantitative method. This is a prospective observational study and patients suspected to have acute coronary syndrome were enrolled. A rapid troponin I test and a quantitative assay were carried out for each patient on arrival and 6 h after admission. A total of 262 patients were enrolled. The degree of agreement between the second rapid qualitative and quantitative troponin I was excellent (κ=0.946; 95% confidence interval, 0.903-0.989). The sensitivity, specificity, negative predictive value, and positive predictive value of the rapid qualitative troponin I test were 92.6, 100, 96.8, and 100%, respectively. In conclusion, this study reveals an excellent agreement between quantitative and qualitative bedside assays 6 h after admission in a sample of Iranian patients in the emergency department.

  14. Performance of highly sensitive cardiac troponin T assay to detect ischaemia at PET-CT in low-risk patients with acute coronary syndrome: a prospective observational study.

    Science.gov (United States)

    Morawiec, Beata; Fournier, Stephane; Tapponnier, Maxime; Prior, John O; Monney, Pierre; Dunet, Vincent; Lauriers, Nathalie; Recordon, Frederique; Trana, Catalina; Iglesias, Juan-Fernando; Kawecki, Damian; Boulat, Olivier; Bardy, Daniel; Lamsidri, Sabine; Eeckhout, Eric; Hugli, Olivier; Muller, Olivier

    2017-07-10

    Highly sensitive troponin T (hs-TnT) assay has improved clinical decision-making for patients admitted with chest pain. However, this assay's performance in detecting myocardial ischaemia in a lowrisk population has been poorly documented. To assess hs-TnT assay's performance to detect myocardial ischaemia at positron emission tomography/CT (PET-CT) in low-risk patients admitted with chest pain. Patients admitted for chest pain with a nonconclusive ECG and negative standard cardiac troponin T results at admission and after 6 hours were prospectively enrolled. Their hs-TnT samples were at T0, T2 and T6. Physicians were blinded to hs-TnT results. All patients underwent a PET-CT at rest and during adenosine-induced stress. All patients with a positive PET-CT result underwent a coronary angiography. Forty-eight patients were included. Six had ischaemia at PET-CT. All of them had ≥1 significant stenosis at coronary angiography. Areas under the curve (95% CI) for predicting significant ischaemia at PET-CT using hs-TnT were 0.764 (0.515 to 1.000) at T0, 0.812(0.616 to 1.000) at T2 and 0.813(0.638 to 0.989) at T6. The receiver operating characteristicbased optimal cut-off value for hs-TnT at T0, T2 and T6 needed to exclude significant ischaemia at PET-CT was <4 ng/L. Using this value, sensitivity, specificity, positive and negative predictive values of hs-TnT to predict significant ischaemia were 83%/38%/16%/94% at T0, 100%/40%/19%/100% at T2 and 100%/43%/20%/100% at T6, respectively. Our findings suggest that in low-risk patients, using the hs-TnT assay with a cut-off value of 4 ng/L demonstrates excellent negative predictive value to exclude myocardial ischaemia detection at PET-CT, at the expense of weak specificity and positive predictive value. ClinicalTrials.gov Identifier: NCT01374607. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly

  15. The structure of the muscle protein complex 4Ca{sup 2+} {center_dot}troponin C {center_dot} troponin

    Energy Technology Data Exchange (ETDEWEB)

    Olah, G.A.; Trewhella, J. [Los Alamos National Laboratory, NM (United States)

    1994-12-31

    Analysis of scattering data based on a Monte Carlo integration method was used to 2+ obtain a low resolution model of the 4Ca{sup 2+}{circ} troponin C{circ}troponin I complex. This modeling method allows rapid testing of plausible structures where the best fit model can be ascertained by a comparison between model structure scattering profiles and measured scattering data. In the best fit model, troponin I appears as a spiral structure 2+ that wraps around 4Ca{sup 2+}{circ}troponin C which adopts an extended dumbbell conformation similar to that observed in the crystal structures of troponin C. The Monte Carlo modeling method can be applied to other biological systems in which detailed structural information is lacking.

  16. A direct comparison of decision rules for early discharge of suspected acute coronary syndromes in the era of high sensitivity troponin.

    Science.gov (United States)

    Chew, Pei Gee; Frost, Fredrick; Mullen, Liam; Fisher, Michael; Zadeh, Heidar; Grainger, Ruth; Albouaini, Khaled; Dodd, James; Patel, Bilal; Velavan, Periaswamy; Kunadian, Babu; Rawat, Anju; Obafemi, Toba; Tong, Sarah; Jones, Julia; Khand, Aleem

    2018-02-01

    We tested the hypothesis that a single high sensitivity troponin at limits of detection (LOD HSTnT) (Acute Coronary Events (GRACE) (acute coronary syndrome. In a prospective cohort study, risk scores were computed in consecutive patients with suspected acute coronary syndrome presenting to the Emergency Room of a large English hospital. Adjudication of myocardial infarction, as per third universal definition, involved a two-physician, blinded, independent review of all biomarker positive chest pain re-presentations to any national hospital. The primary and secondary outcome was a composite of type 1 myocardial infarction, unplanned coronary revascularisation and all cause death (MACE) at six weeks and one year. Of 3054 consecutive presentations with chest pain 1642 had suspected acute coronary syndrome (52% male, median age 59 years, 14% diabetic, 20% previous myocardial infarction). Median time from chest pain to presentation was 9.7 h. Re-presentations occurred in eight hospitals with 100% follow-up achieved. Two hundred and eleven (12.9%) and 279 (17%) were adjudicated to suffer MACE at six weeks and one year respectively. Only HEART ≤3 (negative predictive value MACE 99.4%, sensitivity 97.6%, %discharge 53.4) and LOD HSTnT strategy (negative predictive value MACE 99.8%, sensitivity 99.5%, %discharge 36.9) achieved pre-specified negative predictive value of >99% for MACE at six weeks. For type 1 myocardial infarction alone the negative predictive values at six weeks and one year were identical, for both HEART ≤3 and LOD HSTnT at 99.8% and 99.5% respectively. HEART ≤3 or LOD HSTnT strategy rules out short and medium term myocardial infarction with ≥99.5% certainty, and short-term MACE with >99% certainty, allowing for early discharge of 53.4% and 36.9% respectively of suspected acute coronary syndrome. Adoption of either strategy has the potential to greatly reduce Emergency Room pressures and minimise follow-up investigations. Very early presenters (<3 h

  17. Clinical Use of Ultrasensitive Cardiac Troponin I Assay in Intermediate- and High-Risk Surgery Patients

    Directory of Open Access Journals (Sweden)

    Flávia Kessler Borges

    2013-01-01

    Full Text Available Background. Cardiac troponin levels have been reported to add value in the detection of cardiovascular complications in noncardiac surgery. A sensitive cardiac troponin I (cTnI assay could provide more accurate prognostic information. Methods. This study prospectively enrolled 142 patients with at least one Revised Cardiac Risk Index risk factor who underwent noncardiac surgery. cTnI levels were measured postoperatively. Short-term cardiac outcome predictors were evaluated. Results. cTnI elevation was observed in 47 patients, among whom 14 were diagnosed as having myocardial infarction (MI. After 30 days, 16 patients had major adverse cardiac events (MACE. Excluding patients with a final diagnosis of MI, predictors of cTnI elevation included dialysis, history of heart failure, transoperative major bleeding, and elevated levels of pre- and postoperative N-terminal pro-B-type natriuretic peptide (NT-proBNP. Maximal cTnI values showed the highest sensitivity (94%, specificity (75%, and overall accuracy (AUC 0.89; 95% CI 0.80–0.98 for postoperative MACE. Postoperative cTnI peak level (OR 9.4; 95% CI 2.3–39.2 and a preoperative NT-proBNP level ≥917 pg/mL (OR 3.47; 95% CI 1.05–11.6 were independent risk factors for MACE. Conclusions. cTnI was shown to be an independent prognostic factor for cardiac outcomes and should be considered as a component of perioperative risk assessment.

  18. Effect of antioxidant supplementation on exercise-induced cardiac troponin release in cyclists: a randomized trial.

    Directory of Open Access Journals (Sweden)

    Lieke J J Klinkenberg

    Full Text Available Cardiac troponin is the biochemical gold standard to diagnose acute myocardial infarction. Interestingly however, elevated cardiac troponin concentrations are also frequently observed during and after endurance-type exercise. Oxidative stress associated with prolonged exercise has been proposed to contribute to cardiac troponin release. Therefore, the aim of this study was to assess the effect of 4 week astaxanthin supplementation (a potent cartenoid antioxidant on antioxidant capacity and exercise-induced cardiac troponin release in cyclists.Thirty-two well-trained male cyclists (age 25±5, weight 73±7 kg, maximum O2 uptake 60±5 mL·kg(-1·min(-1, Wmax 5.4±0.5 W·kg(-1; mean ± SD were repeatedly subjected to a laboratory based standardized exercise protocol before and after 4 weeks of astaxanthin (20 mg/day, or placebo supplementation in a double-blind randomized manner. Blood samples were obtained at baseline, at 60 min of cycling and immediately post-exercise (≈ 120 min.The pre-supplementation cycling trial induced a significant rise of median cardiac troponin T concentrations from 3.2 (IQR 3.0-4.2 to 4.7 ng/L (IQR 3.7-6.7, immediately post-exercise (p<0.001. Four weeks of astaxanthin supplementation significantly increased mean basal plasma astaxanthin concentrations from non-detectable values to 175±86 µg·kg(-1. However, daily astaxanthin supplementation had no effect on exercise-induced cardiac troponin T release (p = 0.24, as measured by the incremental area under the curve. Furthermore, the elevation in basal plasma astaxanthin concentrations was not reflected in changes in antioxidant capacity markers (trolox equivalent antioxidant capacity, uric acid, and malondialdehyde. Markers of inflammation (high-sensitivity C-reactive protein and exercise-induced skeletal muscle damage (creatine kinase were equally unaffected by astaxanthin supplementation.Despite substantial increases in plasma astaxanthin concentrations

  19. Epicardial fat thickness in stable coronary artery disease: its relationship with high-sensitive cardiac troponin T and N-terminal pro-brain natriuretic peptide.

    Science.gov (United States)

    Börekçi, Abdurrezzak; Gür, Mustafa; Özaltun, Betül; Baykan, Ahmet Oytun; Harbalioğlu, Hazar; Seker, Taner; Sen, Ömer; Acele, Armağan; Gözükara, Mehmet Yavuz; Kuloğlu, Osman; Koç, Mevlüt; Çayli, Murat

    2014-12-01

    Epicardial adipose tissue is related to coronary atherosclerosis, left ventricle hypertrophy, myocardial dysfunction, cardiomyopathy, and inflammation, which produces a variety of cytokines that influence key pathogenic mechanisms of atherogenesis. The main goal of this study is to examine the relationship between epicardial fat thickness (EFT) and cardiovascular risk markers as well as the complexity of coronary artery disease (CAD) in patients with stable CAD. We prospectively included 439 stable CAD patients undergoing coronary angiography in the present study (mean age: 62.2±10.7 years). Patients were divided into two groups (EFTlow and EFThigh groups) according to their median EFT values. EFT was evaluated by two-dimensional echocardiography before angiography. The SYNTAX score was calculated in all patients. N-terminal pro-brain natriuretic peptide (NT-proBNP), high-sensitive C-reactive protein (hs-CRP), high-sensitive cardiac troponin T (hs-cTnT), uric acid, and other biochemical markers were also measured. Age, SYNTAX score, frequencies of diabetes, hyperlipidemia, and hypertension, NT-proBNP, hs-CRP, hs-cTnT, and uric acid levels were higher in EFThigh group compared with the EFTlow group (P<0.05 for all). EFT was associated independently with age (β=-0.102, P=0.001), diabetes (β=-0.083, P=0.011), SYNTAX score (β=0.352, P<0.001), hs-CRP level (β=0.217, P<0.001), hs-cTnT level (β=0.197, P<0.001), and NT-proBNP level (β=0.300, P<0.001) in multivariate analysis. EFT obtained by echocardiograpy may not only be an easy tool but also an important tool for early detection of increased cardiac risk as well as the extent and complexity of CAD in patients with stable CAD.

  20. FET-biosensor for cardiac troponin biomarker

    Directory of Open Access Journals (Sweden)

    Md Arshad Mohd Khairuddin

    2017-01-01

    Full Text Available Acute myocardial infarction or myocardial infarction (MI is a major health problem, due to diminished flow of blood to the heart, leads to higher rates of mortality and morbidity. The most specific markers for cardiac injury are cardiac troponin I (cTnI and cardiac troponin T (cTnT which have been considered as ‘gold standard’. Due to higher specificity, determination of the level of cardiac troponins became a predominant indicator for MI. Currently, field-effect transistor (FET-based biosensors have been main interest to be implemented in portable sensors with the ultimate application in point-of-care testing (POCT. In this paper, we review on the FET-based biosensor based on its principle of operation, integration with nanomaterial, surface functionalization as well as immobilization, and the introduction of additional gate (for ambipolar conduction on the device architecture for the detection of cardiac troponin I (cTnI biomarker.

  1. Can we monitor heart attack in the troponin era: evidence from a population-based cohort study

    Directory of Open Access Journals (Sweden)

    Rankin Jamie M

    2011-06-01

    Full Text Available Abstract Background Troponins (highly sensitive biomarkers of myocardial damage increase counts of myocardial infarction (MI in clinical practice, but their impact on trends in admission rates for MI in National statistics is uncertain. Methods Cases coded as MI or other cardiac diagnoses in the Hospital Morbidity Data Collection (MI-HMDC in Western Australia in 1998 and 2003 were classified using revised criteria for MI developed by an International panel convened by the American Heart Association (AHA criteria using information on symptoms, ECGs and cardiac biomarkers abstracted from samples of medical notes. Age-sex standardized rates of MI-HMDC were compared with rates of MI based on AHA criteria including troponins (MI-AHA or traditional biomarkers only (MI-AHAck. Results Between 1998 and 2003, rates of MI-HMDC decreased by 3.5% whereas rates of MI-AHA increased by 17%, a difference largely due to increased false-negative cases in the HMDC associated with marked increased use of troponin tests in cardiac admissions generally, and progressively lower test thresholds. In contrast, rates of MI-AHAck declined by 18%. Conclusions Increasing misclassification of MI-AHA by the HMDC may be due to reluctance by clinicians to diagnose MI based on relatively small increases in troponin levels. These influences are likely to continue. Monitoring MI using AHA criteria will require calibration of commercially available troponin tests and agreement on lower diagnostic thresholds for epidemiological studies. Declining rates of MI-AHAck are consistent with long-standing trends in MI in Western Australia, suggesting that neither MI-HMDC nor MI-AHA reflect the true underlying population trends in MI.

  2. Troponin T is a strong marker of mortality in hospitalized patients

    DEFF Research Database (Denmark)

    Iversen, Kasper; Køber, Lars; Gøtze, Jens Peter

    2013-01-01

    hospitalized population are unknown. METHODS: Consecutive patients aged >40years admitted to a district hospital between 1 April 1998 and 31 March 1999 were included. A comprehensive medical interview and clinical examination were performed including echocardiography and measurement of natriuretic peptides...... and troponin T with a high-sensitivity assay (hs-TnT). RESULTS: Serum for analyses of hs-TnT was available from 1176 patients. Patients were 73.7years old on average (interquartile range, 64.5-80.0years), 59.2% were women and median follow-up was 11.4years. The prevalence of elevated hs-TnT (> 99th percentile...

  3. Head-to-head comparison of cardiac troponin T and troponin I in patients without acute coronary syndrome

    DEFF Research Database (Denmark)

    Árnadóttir, Ásthildur; Falk Klein, Christine; Iversen, Kasper

    2017-01-01

    BACKGROUND: Cardiac-specific troponin T (cTnT) and troponin I (cTnI) are considered diagnostically equal in patients with acute coronary syndrome (ACS). The aim of this systematic review was to compare the prevalence and prognostic strength of elevations of cTnT and cTnI in patients with other...

  4. Troponin T or troponin I or CK-MB (or none?).

    Science.gov (United States)

    Collinson, P O

    1998-11-01

    patients, thrombolysis is the treatment of choice. Patients presenting with ST segment elevation represents the minority of patients with probable ACS 9.6% of all patients presenting to our hospital. The majority require risk stratification into high- and low-risk groups. It is here that cardiac troponins have a major role. The measurement of cTnT has been shown in a large number of studies to enable risk stratification of patients with unstable angina. The combination of cTnT, admission ECG and stress ECG can be used for a comprehensive risk stratification of patients with unstable angina. The combination of cTnT, admission ECG and stress ECG can be used for a comprehensive risk stratification which can be completed by 24 h from admission, as well as allowing a safe discharge policy from the ED. Measurements of cardiac troponins can also be used to predict prognosis in patients with other diagnostic categories. Patients with cardiac failure can be risk stratified according to cTnT status. cTnT status on admission allows subdivision into high- and low-risk groups in patients presenting with ST segment elevation. Certainly, cTnT measurement can be incorporated into a clinical decision-making strategy to assign patients to investigation and management pathways. There is evidence that cTnT may be useful to guide therapeutic options. The major issue is one of cost. In the U.K. model of managed care with undemanding diagnostic standards, the role of cTnT will be to enhance clinical decision-making strategies, to provide accurate diagnosis and to reduce lengths of stay. This can be shown to have potential for major improvements in cost efficiency. Improvements in diagnostic accuracy can reduce inappropriate long-term drug therapy. In systems with a more aggressive laboratory investigation strategy, rationalization of test numbers will provide an immediate cost reduction while improving quality. Finally, use of point-of-care testing (POCT) means that biochemical testing can be pe

  5. Selectivity verification of cardiac troponin monoclonal antibodies for cardiac troponin detection by using conventional ELISA

    Science.gov (United States)

    Fathil, M. F. M.; Arshad, M. K. Md; Gopinath, Subash C. B.; Adzhri, R.; Ruslinda, A. R.; Hashim, U.

    2017-03-01

    This paper presents preparation and characterization of conventional enzyme-linked immunosorbent assay (ELISA) for cardiac troponin detection to determine the selectivity of the cardiac troponin monoclonal antibodies. Monoclonal antibodies, used to capture and bind the targets in this experiment, are cTnI monoclonal antibody (MAb-cTnI) and cTnT monoclonal antibody (MAb-cTnT), while both cardiac troponin I (cTnI) and T (cTnT) are used as targets. ELISA is performed inside two microtiter plates for MAb-cTnI and MAb-cTnT. For each plate, monoclonal antibodies are tested by various concentrations of cTnI and cTnT ranging from 0-6400 µg/l. The binding selectivity and level of detection between monoclonal antibodies and antigen are determined through visual observation based on the color change inside each well on the plate. ELISA reader is further used to quantitatively measured the optical density of the color changes, thus produced more accurate reading. The results from this experiment are utilized to justify the use of these monoclonal antibodies as bio-receptors for cardiac troponin detection by using field-effect transistor (FET)-based biosensors coupled with substrate-gate in the future.

  6. Origin of noise in liquid-gated Si nanowire troponin biosensors

    Science.gov (United States)

    Kutovyi, Y.; Zadorozhnyi, I.; Hlukhova, H.; Handziuk, V.; Petrychuk, M.; Ivanchuk, Andriy; Vitusevich, S.

    2018-04-01

    Liquid-gated Si nanowire field-effect transistor (FET) biosensors are fabricated using a complementary metal-oxide-semiconductor-compatible top-down approach. The transport and noise properties of the devices reflect the high performance of the FET structures, which allows label-free detection of cardiac troponin I (cTnI) molecules. Moreover, after removing the troponin antigens the structures demonstrate the same characteristics as before cTnI detection, indicating the reusable operation of biosensors. Our results show that the additional noise is related to the troponin molecules and has characteristics which considerably differ from those usually recorded for conventional FETs without target molecules. We describe the origin of the noise and suggest that noise spectroscopy represents a powerful tool for understanding molecular dynamic processes in nanoscale FET-based biosensors.

  7. Troponins Test

    Science.gov (United States)

    ... lab's website in order to provide you with background information about the test(s) you had performed. You will need to return ... C, Banfi G, Guidi GC. Influence of a half-marathon run on NT-proBNP and troponin ... MedlinePlus Medical Encyclopedia [On-line information]. Available online ...

  8. S-glutathionylation of troponin I (fast) increases contractile apparatus Ca2+ sensitivity in fast-twitch muscle fibres of rats and humans.

    Science.gov (United States)

    Mollica, J P; Dutka, T L; Merry, T L; Lamboley, C R; McConell, G K; McKenna, M J; Murphy, R M; Lamb, G D

    2012-03-15

    Oxidation can decrease or increase the Ca2+ sensitivity of the contractile apparatus in rodent fast-twitch (type II) skeletal muscle fibres, but the reactions and molecular targets involved are unknown. This study examined whether increased Ca2+ sensitivity is due to S-glutathionylation of particular cysteine residues. Skinned muscle fibres were directly activated in heavily buffered Ca2+ solutions to assess contractile apparatus Ca2+ sensitivity. Rat type II fibres were subjected to S-glutathionylation by successive treatments with 2,2′-dithiodipyridine (DTDP) and glutathione (GSH), and displayed a maximal increase in pCa50 (−log10 [Ca2+] at half-maximal force) of ∼0.24 pCa units, with little or no effect on maximum force or Hill coefficient. Partial similar effect was produced by exposure to oxidized gluthathione (GSSG, 10 mM) for 10 min at pH 7.1, and near-maximal effect by GSSG treatment at pH 8.5. None of these treatments significantly altered Ca2+ sensitivity in rat type I fibres. Western blotting showed that both the DTDP–GSH and GSSG–pH 8.5 treatments caused marked S-glutathionylation of the fast troponin I isoform (TnI(f)) present in type II fibres, but not of troponin C (TnC) or myosin light chain 2. Both the increased Ca2+ sensitivity and glutathionylation of TnI(f) were blocked by N-ethylmaleimide (NEM). S-nitrosoglutathione (GSNO) also increased Ca2+ sensitivity, but only in conditions where it caused S-glutathionylation of TnI(f). In human type II fibres from vastus lateralis muscle, DTDP–GSH treatment also caused similar increased Ca2+ sensitivity and S-glutathionylation of TnI(f). When the slow isoform of TnI in type I fibres of rat was partially substituted (∼30%) with TnI(f), DTDP–GSH treatment caused a significant increase in Ca2+ sensitivity (∼0.08 pCa units). TnIf in type II fibres from toad and chicken muscle lack Cys133 present in mammalian TnIf, and such fibres showed no change in Ca2+ sensitivity with DTDP–GSH nor any S

  9. The Correlation between Troponin and Ferritin Serum Levels in the Patients with Major Beta-Thalassemia

    Directory of Open Access Journals (Sweden)

    Iraj Shahramian

    2013-06-01

    Full Text Available Background: Thalassemia is a hereditary hemoglobinopathy whose most common complication is cardiac involvement which ends up in these patients’ death. Since troponin is a sensitive and specific marker for the detection of microinfarct, we studied the relationship between troponin and ferritin serum levels for early diagnosis of cardiac involvement in these patients. Materials and Methods: This case-control study was performed on 80 patients, including 40 patients with major thalassemia and normal echocardiography and 40 healthy volunteers ranging from 6 months to 16 years old. All the children were examined and the eligible children who were not infected with known heart disease, iron deficiency anemia, kidney disease, diabetes, fever, and systemic diseases were enrolled into the study after obtaining written informed consents from their parents. At 8:00 A.M. before breakfast, 5cc blood was drawn from these children. After collecting the samples, ferritin and troponin serum levels were evaluated using ELISA and electro- kymonolonsense methods, respectively. The gathered data were analyzed through the SPSS statistical software (v. 20 and T-test. Besides, P value<0.05 was considered as statistically significant. Results: The study results revealed a significant difference between the two groups regarding the mean of the serum levels of troponin (P=0.045 and ferritin (P=0.001. In this study, no significant correlation was observed between serum troponin and ferritin levels and age and BMI in the two groups. Also, no significant relationship was found between serum troponin level and sex (P=0.264. Conclusions: In microinfarct, troponin increases independent of ferritin; therefore, it can be used for early detection of cardiac involvement in thalassemia patients to determine the sub-clinical effects.

  10. Motor neurone disease presenting with raised serum Troponin T.

    Science.gov (United States)

    Mamo, Jonathan P

    2015-05-01

    Myocardial damage indicated by a rise in cardiac Troponin may not necessarily be due to a cardiac event. Many diseases such as sepsis, pulmonary embolism, heart and renal failure can also be associated with an elevated cardiac Troponin level. This brief report discusses the rare event of a patient with motor neurone disease, where the possible diagnosis of acute myocardial infarction arose due to an elevated cardiac Troponin. A 69-year-old gentleman presented with a history of a central chest ache of mild intensity, lasting a total of 2 h prior to complete resolution. Multiple cardiac Troponin assays were elevated, and echocardiography did not show any acute changes of myocardial damage. His electrocardiogram was also normal. This patient's raised cardiac Troponin was therefore explained on the basis of his active motor neurone disease. This rare case outlines the importance of considering motor neurone disease as a cause of elevated cardiac Troponin in the absence of clinical evidence of an acute coronary event. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  11. Multi-centre evaluation of recent troponin assays for the diagnosis of NSTEMI

    Directory of Open Access Journals (Sweden)

    Camille Chenevier-Gobeaux

    2018-07-01

    Full Text Available Objectives: We aimed to compare the use of nine different cardiac troponin (cTn assays (2 cTnT and 7 cTnI for the diagnosis of NSTEMI in a single multi-centre population. Design and methods: One hundred and fifty-eight patients were included (mean age 60 years, SD 17 years, including 23 patients (14% with NSTEMI. Results: The analytical comparison highlighted a large heterogeneity of cTn assays, as reflected by percentages of patients with detectable cTn, correlation coefficients, Passing-Bablok comparisons and concordance coefficients. Correlations within cTnI assays were good and correlation within cTnT assays was excellent. Diagnostic performances demonstrated that each cTn assay has specific threshold values. Furthermore, some assays (HS-cTnI and T, cTnI-Pathfast and cTnI-Centaur indicated high sensitivity and negative predictive value using the limit of detection (LoD diagnostic strategy. For the latter assays, a significant increase in specificity was found when using the 99th percentile or the H0-H3 strategies, in comparison to the LoD strategy. When applying the European Society of Cardiology H0-H3 algorithm, comparable diagnostic performances were obtained. Conclusion: All 9 cTn assays indicated overall good diagnostic performances for the diagnosis of NSTEMI in emergency departments when the recommended algorithm based on the variation of cTn value between two measurements at admission and 3 h later was used. Keywords: Cardiac troponin, High-sensitivity assay, Chest pain, Emergency department, NSTEMI, Analytical evaluation

  12. Diagnosis of Unstable Angina Pectoris Has Declined Markedly with the Advent of More Sensitive Troponin Assays

    DEFF Research Database (Denmark)

    D'Souza, Maria; Sarkisian, Laura; Saaby, Lotte

    2015-01-01

    ]) was established in cases of a rise and/or fall of cardiac troponin I together with cardiac ischemic features. Patients with unstable chest discomfort and cardiac troponin I values below the decision limit of myocardial infarction were diagnosed as having unstable angina pectoris. The definition of acute coronary...... syndrome included unstable angina pectoris, NSTEMI, and STEMI. Mortality data were obtained from the Danish Civil Personal Registration System. RESULTS: Of 3762 consecutive patients, 516 had acute coronary syndrome. Unstable angina pectoris was present in 7%, NSTEMI in 67%, and STEMI in 26%. The NSTEMI...... patients were older, more frequently women, and had more comorbidities than patients with unstable angina pectoris and STEMI. At median follow-up of 3.2 years 195 patients had died: 14% of unstable angina pectoris, 45% of NSTEMI, and 25% of STEMI patients. Age-adjusted log-rank statistics revealed...

  13. Prognostic prediction of troponins in cardiac myxoma: case study with literature review

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    2015-04-01

    Full Text Available AbstractObjective:It was supposed that troponins in cardiac myxoma patients might be in a same fashion as in the conditions without myocardial injury. In order to verify this hypothesis, troponins in cardiac myxoma patients were discussed by presenting a comprehensive retrieval of the literature with incorporating the information of a recent patient.Methods:Postoperative detections of troponin I, creatine kinase isoenzyme MB (CK-MB and N-terminal pro-B-type natriuretic peptide revealed elevated troponin I and CK-MB and normal N-terminal pro-B-type natriuretic peptide. Postoperative troponin I and CK-MB shared a same trend, reaching a peak value at postoperative hour 2, gradually decreased on postoperative day 1, and reached a plateau on postoperative days 7 and 13. A significant correlation could be noted between the postoperative values of the two indicators (Y=0.0714X + 0.6425, r2=0.9111, r=0.9545, P=0.0116. No significant linear correlation between troponin I and N-terminal pro-B-type natriuretic peptide were found. Literature review of troponins in cardiac myxoma patients revealed the uncomplicated patients had a normal or only slightly elevated troponin before open heart surgery. However, the complicated patients (with cerebral or cardiac events showed a normal preoperative troponin in 3 (23.1% and an elevated troponin in 10 (76.9% patients (χ2=7.54, P=0.0169, Fisher's exact test. The overall quantitative result of troponin I was 2.45±2.53 µg/L, and that of troponin T was 3.10±4.29 mg/L, respectively.Conclusion:Troponins are not necessarily elevated in patients with a cardiac myxoma without coronary syndrome. By contrast, patients with a cardiac myxoma with an elevated troponin may herald the presence of an associated coronary event. An old cerebral infarct does not necessarily cause an elevation of troponin or B-type natriuretic peptide, or new neurological events, but might lead to a delayed awakening.

  14. Cardiac magnetic resonance imaging in patients with chest pain, high troponin levels and absence of coronary artery obstruction

    International Nuclear Information System (INIS)

    Avegliano, G.P.; Costabel, J.P.; Kuschnir, P.; Thierer, J.; Alves de Lima, A.; Sanchez, G.; Ronderos, J.; Huguet, M.; Petit, M.; Frangi, A.A.

    2011-01-01

    The prevalence of myocardial infarction with angiographically normal coronary arteries is approximately 7-10%. The etiological diagnosis is sometimes difficult and is important in terms of clinical practice and prognosis. The goal of our study was to show a series of consecutive patients with an initial diagnosis of acute coronary syndrome with high troponin levels and absence of coronary artery obstruction in which cardiac magnetic resonance imaging (CMRI) gave a description of the myocardial lesion, orientating towards the etiological diagnosis. From January 2005 to December 2009, 720 consecutive patients with an initial diagnosis of acute coronary syndrome and elevated troponins were included; 64 of these patients did not present angiographically significant coronary artery stenosis. Within 72 ± 24 h after coronary angiography, these patients underwent CMRI using b-SSFP sequences for cine imaging in short-axis, 2-, 3- and 4- chamber views for the evaluation of segmental wall motion, with T2-weighted and delayed enhancement (DE) images of the myocardium with an 'inversion-recovery' sequence. The following diagnoses were made: myocarditis (39 patients); myocardial infarction (12 patients); Tako-Tsubo syndrome (8 patients); apical hypertrophic cardiomyopathy (2 patients); 3 patients remained without diagnosis. These findings demonstrate the usefulness of CMRI in the clinical scenario of patients with chest pain, inconclusive ECG findings and high troponin levels with angiographically normal coronary arteries. The presence and distribution pattern of DE make it possible to define the etiological diagnosis and interpret the physiopathological process. (authors) [es

  15. Anti-troponin I antibodies in renal transplant patients.

    Science.gov (United States)

    Nunes, José Pedro L; Sampaio, Susana; Cerqueira, Ana; Kaya, Ziya; Oliveira, Nuno Pardal

    2015-02-01

    To characterize the prevalence and clinical correlates of anti-troponin I antibodies in renal transplant patients. A group of 48 consecutive renal transplant patients under immunosuppressive therapy were studied. Anti-troponin I antibodies were measured and clinical data were retrieved. An anti-troponin I antibody titer renal transplant patients, and are not associated with the presence of clinical heart disease, but are associated with lack of statin therapy. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  16. Mechanism of troponin elevations in patients with acute ischemic stroke

    DEFF Research Database (Denmark)

    Jensen, Jesper K.; Atar, Dan; Mickley, Hans

    2007-01-01

    the introduction of troponin in the diagnosis of acute myocardial infarction, this marker has been measured in a number of other conditions as well. One of these conditions is acute ischemic stroke, causing diagnostic dilemmas for clinicians. Because various electrocardiographic alterations have also been reported...... in these patients, it has been suggested that elevated troponin levels are somehow neurologically mediated, thus not caused by direct cardiac release. In conclusion, this review examines the available studies that systematically measured troponin in patients with acute ischemic stroke to properly interpret troponin...... elevations in these patients Udgivelsesdato: 2007-Mar-15...

  17. Impact of high-sensitivity cardiac troponin I assays on patients presenting to an emergency department with suspected acute coronary syndrome.

    Science.gov (United States)

    Yip, Thomas P Y; Pascoe, Heather M; Lane, Stephen E

    2014-08-04

    To determine whether introduction of high-sensitivity cardiac troponin I (hscTn-I) assays affected management of patients presenting with suspected acute coronary syndrome (ACS) to the emergency department (ED) of a tertiary referral hospital. A retrospective analysis of all patients presenting to the Geelong Hospital ED with suspected ACS from 23 April 2010 to 22 April 2013 -2 years before and 1 year after the changeover to hscTn-I assays on 23 April 2012. Hospital admission rates, time spent in the ED, rates of coronary angiography, rates of percutaneous coronary intervention (PCI) and coronary artery bypass graft surgery (CABGS), rates of discharge with a diagnosis of ACS, and rates of inhospital mortality. 12 360 consecutive patients presented with suspected ACS during the study period; 1897 were admitted to Geelong Hospital in the 2 years before and 944 in the 1 year after the changeover to hscTn-I assays. Comparing the two patient groups, there was no statistically significant difference in all-hospital admission rates (95% CI for the difference, - 3.1% to 0.3%; P = 0.10) or proportion of patients subsequently discharged with a diagnosis of ACS (95% CI for the difference, - 2.3% to 5.4%; P = 0.43). After the changeover, the median time patients spent in the ED was 11.5% shorter (3.85 h v 4.35 h; 95% CI for the difference, - 0.59 to - 0.43; P rise in the proportion of patients who had invasive treatment (PCI and/or CABGS) (95% CI for the difference, - 0.4% to 6.3%; P = 0.08). Inhospital mortality rates from ACS did not change significantly (95% CI for the difference, - 1.5% to 0.8%; P = 0.43). The introduction of hscTn-I assays appeared to be associated with more rapid diagnosis, resulting in less time spent in the ED, without a change in hospital admission rates. A higher proportion of patients had coronary angiographies after the changeover, but there was no significant change in rates of invasive treatment or inhospital mortality.

  18. DIAGNOSTIC EFFICACY OF CARDIAC TROPONIN-T IN ACUTE MYOCARDIAL INFARCTION PATIENTS ADMITTED IN INTENSIVE CARDIAC CARE UNIT

    Directory of Open Access Journals (Sweden)

    Tapan

    2016-03-01

    Full Text Available INTRODUCTION Myocardial infarction is a common and severe manifestation of ischaemic heart disease (IHD. Acute myocardial infarction (AMI is the result of death of heart muscle cells following either from a prolonged or severe ischaemia. The World Health Organisation emphasises IHD as our "Modern Epidemic" and AMI as common cause of sudden death. AIM The present study has been undertaken with the aim to assess the role of cardiac Troponin-T in early diagnosis of AMI and to evaluate its positive roles over CK-MB and LDH enzyme assays. The study also aims to find out the role of cardiac Troponin-T test, where ECG changes are nondiagnostic and inconclusive for AMI. MATERIAL & METHOD One hundred cases of provisionally diagnosed AMI, who were admitted during June 2012 to July 2015 in ICC Unit of TMC & Dr. BRAM Teaching Hospital, formed the subjects for the study. Those patients reported 2 to 10 hours after onset of chest pain were included in this study. Patients reported beyond 10 hours after onset of chest pain of AMI cases and patients having chest pain of non-AMI causes are excluded from the study. The provisional diagnosis of AMI was done on the basis of the history, chest pain, clinical findings and ECG changes. Trop-T test (Troponin-T sensitive rapid test by Muller Bardoff, et al, 1991 as well as CK-MB (creatine kinase-MB isoenzymeassays were performed immediately for each and every patient. Trop-T test was repeated in some selective cases where the early changes were insignificant and the results were compared with those of CK-MB, at different period of the disease onset. RESULTS The rapid cardiac Troponin-T test (CTn-T has 100% specificity for AMI whereas CK-MB and LDH have specificities of 80% and 60% respectively. The CTn-T has diagnostic efficiency of 92% for AMI but ECG has only 69% sensitivity and 80% specificity. The overall diagnostic efficacy of cardiac Troponin-T is higher than that of CK-MB, LDH and ECG (94% versus 92%, 91 % and 72

  19. The ZnO-FET Biosensor for Cardiac Troponin I

    Science.gov (United States)

    Fathil, M. F. M.; Arshad, M. K. Md; Nuzaihan, M. N. M.; Gopinath, Subash C. B.; Ruslinda, A. R.; Hashim, U.

    2018-03-01

    This paper investigates the influence of substrate-gate coupling on the ZnO-FET biosensor’s sensitivity for detection of cardiac troponin I (cTnI), a ‘gold standard’ biomarker for acute myocardial infarction (AMI). The FET-based device with introduction of substrate-gate coupling on p-type silicon-on-insulator (SOI) substrate is fabricated using conventional lithography processes. An n-type zinc oxide (ZnO) thin film deposited via electron-beam evaporator is used as transducer for bridging the source and drain regions. Surface modifications via functionalization with 3-aminopropyltriethoxysilane (APTES) and glutaraldehyde (GA) as chemical linkers, followed by immobilization of cTnI monoclonal antibody (MAb-cTnI) as bio-receptor on the ZnO thin film allow different concentration of cTnI detection with high selectivity. The device’s sensitivity increases up to 9 %·(g/ml)-1 with the increase of the substrate-gate voltage (VSG) up to -10 V at very low limit of detection (LOD) down to 1.6 fg/ml.

  20. Predictive value of routine point-of-care cardiac troponin T measurement for prehospital diagnosis and risk-stratification in patients with suspected acute myocardial infarction

    DEFF Research Database (Denmark)

    Rasmussen, Martin B; Stengaard, Carsten; Sørensen, Jacob T

    2017-01-01

    -of-care cardiac troponin T measurements (11.0%) had a value ≥50 ng/l, including 966 with acute myocardial infarction (sensitivity: 44.2%, specificity: 92.8%). Patients presenting with a prehospital point-of-care cardiac troponin T value ≥50 ng/l had a one-year mortality of 24% compared with 4.8% in those...... with values analysis: point-of-care cardiac troponin T≥50 ng/l (hazard ratio 2.10, 95% confidence interval: 1.90-2.33), congestive heart failure (hazard ratio 1.93, 95% confidence interval: 1......OBJECTIVE: The purpose of this study was to determine the predictive value of routine prehospital point-of-care cardiac troponin T measurement for diagnosis and risk stratification of patients with suspected acute myocardial infarction. METHODS AND RESULTS: All prehospital emergency medical service...

  1. Midregional-proAtrial Natriuretic Peptide and High Sensitive Troponin T Strongly Predict Adverse Outcome in Patients Undergoing Percutaneous Repair of Mitral Valve Regurgitation.

    Directory of Open Access Journals (Sweden)

    Jochen Wöhrle

    Full Text Available It is not known whether biomarkers of hemodynamic stress, myocardial necrosis, and renal function might predict adverse outcome in patients undergoing percutaneous repair of severe mitral valve insufficiency. Thus, we aimed to assess the predictive value of various established and emerging biomarkers for major adverse cardiovascular events (MACE in these patients.Thirty-four patients with symptomatic severe mitral valve insufficiency with a mean STS-Score for mortality of 12.6% and a mean logistic EuroSCORE of 19.7% undergoing MitraClip therapy were prospectively included in this study. Plasma concentrations of mid regional-proatrial natriuretic peptide (MR-proANP, Cystatin C, high-sensitive C-reactive protein (hsCRP, high-sensitive troponin T (hsTnT, N-terminal B-type natriuretic peptide (NT-proBNP, galectin-3, and soluble ST-2 (interleukin 1 receptor-like 1 were measured directly before procedure. MACE was defined as cardiovascular death and hospitalization for heart failure (HF.During a median follow-up of 211 days (interquartile range 133 to 333 days, 9 patients (26.5% experienced MACE (death: 7 patients, rehospitalization for HF: 2 patients. Thirty day MACE-rate was 5.9% (death: 2 patients, no rehospitalization for HF. Baseline concentrations of hsTnT (Median 92.6 vs 25.2 ng/L, NT-proBNP (Median 11251 vs 1974 pg/mL and MR-proANP (Median 755.6 vs 318.3 pmol/L, all p<0.001 were clearly higher in those experiencing an event vs event-free patients, while other clinical variables including STS-Score and logistic EuroSCORE did not differ significantly. In Kaplan-Meier analyses, NT-proBNP and in particular hsTnT and MR-proANP above the median discriminated between those experiencing an event vs event-free patients. This was further corroborated by C-statistics where areas under the ROC curve for prediction of MACE using the respective median values were 0.960 for MR-proANP, 0.907 for NT-proBNP, and 0.822 for hsTnT.MR-proANP and hsTnT strongly

  2. Risk prediction in stable cardiovascular disease using a high-sensitivity cardiac troponin T single biomarker strategy compared to the ESC-SCORE.

    Science.gov (United States)

    Biener, Moritz; Giannitsis, Evangelos; Kuhner, Manuel; Zelniker, Thomas; Mueller-Hennessen, Matthias; Vafaie, Mehrshad; Stoyanov, Kiril M; Neumann, Franz-Josef; Katus, Hugo A; Hochholzer, Willibald; Valina, Christian Marc

    2018-01-01

    To evaluate the prognostic performance of high-sensitivity cardiac troponin T (hs-cTnT) compared with the ESC-SCORE. We included low-risk outpatients with stable cardiovascular (CV) disease categorised into need for non-secondary and secondary prevention. The prognostication of hs-cTnT at index visit was compared with the European Society of Cardiology-Systematic COronary Risk Evaluation (ESC-SCORE) with respect to all-cause mortality (ACM) and two composite endpoints (ACM, acute myocardial infarction (AMI) and stroke and ACM, AMI, stroke and rehospitalisation for acute coronary syndrome (ACS) and decompensated heart failure (DHF)). Within a median follow-up of 796 days, a total of 16 deaths, 32 composite endpoints of ACM, AMI and stroke and 83 composite endpoints of ACM, AMI, stroke, rehospitalisation for ACS and DHF were observed among 693 stable low-risk outpatients. Using C-statistics, measurement of hs-cTnT alone outperformed the ESC-SCORE for the prediction of ACM in the entire study population (Δarea under the curve (AUC) 0.221, p=0.0039) and both prevention groups (non-secondary: ΔAUC 0.164, p=0.0208; secondary: ΔAUC 0.264, p=0.0134). For the prediction of all other secondary endpoints, hs-cTnT was at least as effective as the ESC-SCORE, both in secondary and non-secondary prevention. Using continuous and categorical net reclassification improvement and integrated discrimination improvement, hs-cTnT significantly improved reclassification regarding all endpoints in the entire population and in the secondary prevention cohort. In non-secondary prevention, hs-cTnT improved reclassification only for ACM. The results were confirmed in an independent external cohort on 2046 patients. Hs-cTnT is superior to the multivariable ESC-SCORE for the prediction of ACM and a composite endpoint in stable outpatients with and without relevant CV disease. NCT01954303; Pre-results.

  3. 24-Hour Kinetics of Cardiac Troponin-T Using a "High-Sensitivity" Assay in Thoroughbred Chuckwagon Racing Geldings after Race and Associated Clinical Sampling Guidelines.

    Science.gov (United States)

    Shields, E; Seiden-Long, I; Massie, S; Leguillette, R

    2018-01-01

    A "high-sensitivity" cardiac troponin-T (hscTnT) assay recently has been validated for use in horses and is a specific biomarker of myocardial damage. Postexercise release kinetics of cTnT utilizing the hscTnT assay have yet to be established in horses. To determine: (1) cTnT release kinetics in racing Thoroughbreds after a high-intensity 5/8th mile Chuckwagon race; (2) the effects of age on pre- and postrace cTnT concentrations; and (3) sampling guidelines for clinicians evaluating horses presenting after exercise. Samples were obtained from 38 Thoroughbred geldings aged 5-16 years before racing and immediately, 2, 3, 4, 6, 12, and 24 hour postrace. Prospective, observational study with convenience sampling. A fifth-generation hscTnT assay was used for plasma sample analysis, and concentrations were compared at all time-points. Correlations were determined between cTnT concentrations and age. Biochemistry analysis was performed to assess rhabdomyolysis, renal failure, and exercise-induced dehydration. All horses with measureable cTnT concentrations had significant postexercise increases in cTnT with a median peak (8.0 ng/L) at 3-hour postrace. All horses had peak postexercise cTnT concentrations 2- to 6-hour postrace ≤ the 99th percentile upper reference limit of 23.2 ng/L, after which all cTnT concentrations decreased until returning to baseline by 12-24 hours. There was no correlation over time between cTnT concentrations and age. In racing Thoroughbreds completing short-duration, high-intensity Chuckwagon races, cTnT concentrations are expected to be increased 2- to 6-hour postrace and to decrease by 12-24 hours while remaining ≤23.2 ng/L throughout. This study contributes to establishing guidelines for clinical use of the hscTnT assay in exercising horses. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  4. Factors contributing to troponin exchange in myofibrils and in solution.

    Science.gov (United States)

    She, M; Trimble, D; Yu, L C; Chalovich, J M

    2000-01-01

    The troponin complex in a muscle fiber can be replaced with exogenous troponin by using a gentle exchange procedure in which the actin-tropomyosin complex is never devoid of a full complement of troponin (Brenner et al. (1999) Biophys J 77: 2677-2691). The mechanism of this exchange process and the factors that influence this exchange are poorly understood. In this study, the exchange process has now been examined in myofibrils and in solution. In myofibrils under rigor conditions, troponin exchange occurred preferentially in the region of overlap between actin and myosin when the free Ca2+ concentration was low. At higher concentrations of Ca2+, the exchange occurred uniformly along the actin. Ca2+ also accelerated troponin exchange in solution but the effect of S1 could not be confirmed in solution experiments. The rate of exchange in solution was insensitive to moderate changes in pH or ionic strength. Increasing the temperature resulted in a two-fold increase in rate with each 10 degrees C increase in temperature. A sequential two step model of troponin binding to actin-tropomyosin could simulate the observed association and dissociation transients. In the absence of Ca2+ or rigor S1, the following rate constants could describe the binding process: k1 = 7.12 microM(-1) s(-1), k(-1) = 0.65 s(-1), k2 = 0.07 s(-1), k(-2) = 0.0014 s(-1). The slow rate of detachment of troponin from actin (k(-2)) limits the rate of exchange in solution and most likely contributes to the slow rate of exchange in fibers.

  5. Troponin C Mutations Partially Stabilize the Active State of Regulated Actin and Fully Stabilize the Active State When Paired with Δ14 TnT.

    Science.gov (United States)

    Baxley, Tamatha; Johnson, Dylan; Pinto, Jose R; Chalovich, Joseph M

    2017-06-13

    Striated muscle contraction is regulated by the actin-associated proteins tropomyosin and troponin. The extent of activation of myosin ATPase activity is lowest in the absence of both Ca 2+ and activating cross-bridges (i.e., S1-ADP or rigor S1). Binding of activating species of myosin to actin at a saturating Ca 2+ concentration stabilizes the most active state (M state) of the actin-tropomyosin-troponin complex (regulated actin). Ca 2+ binding alone produces partial stabilization of the active state. The extent of stabilization at a saturating Ca 2+ concentration depends on the isoform of the troponin subunits, the phosphorylation state of troponin, and, in the case of cardiac muscle, the presence of hypertrophic cardiomyopathy-producing mutants of troponin T and troponin I. Cardiac dysfunction is also associated with mutations of troponin C (TnC). Troponin C mutants A8V, C84Y, and D145E increase the Ca 2+ sensitivity of ATPase activity. We show that these mutants change the distribution of regulated actin states. The A8V and C84Y TnC mutants decreased the inactive B state distribution slightly at low Ca 2+ concentrations, but the D145E mutants had no effect on that state. All TnC mutants increased the level of the active M state compared to that of the wild type, at a saturating Ca 2+ concentration. Troponin complexes that contained two mutations that stabilize the active M state, A8V TnC and Δ14 TnT, appeared to be completely in the active state in the presence of only Ca 2+ . Because Ca 2+ gives full activation, in this situation, troponin must be capable of positioning tropomyosin in the active M state without the need for rigor myosin binding.

  6. Increase in Cardiac Troponin I in a Lamb with Tetralogy of Fallot

    Science.gov (United States)

    NEUWALD, Elisa Barp; SOARES, Frederico Aécio Carvalho; DREYER, Cristina Terres; CARNESELLA, Samuel; WOUTERS, Angelica Terezinha Barth; GONZÁLEZ, Félix Hilario Diaz; DRIEMEIER, David

    2013-01-01

    ABSTRACT This study describes a case of tetralogy of Fallot in a lamb showing failure to thrive and signs of respiratory distress. Physical examination, electrocardiography, thoracic radiographies, echocardiography and cardiac troponin I evaluation were performed. The value of cardiac troponin I was compared with the values of 10 healthy lambs of the same age and breed, and the affected animal demonstrated an increase in cardiac troponin I. Due to the poor prognosis, euthanasia was indicated, and necropsy confirmed the diagnosis. This is the first report of an increase in cardiac troponin I in a lamb with tetralogy of Fallot. PMID:23685750

  7. 5A.01: CORONARY ATHEROSCLEROSIS AND ADVERSE OUTCOME IN HYPERTENSIVE PATIENTS WITH RECENT-ONSET ATRIAL FIBRILLATION AND TROPONIN RISE.

    Science.gov (United States)

    Conti, A; Angeli, E; Trausi, F; Grifoni, C; Lazzeretti, D; Bianchi, S; Catarzi, S; Covelli, A; Perrotta, M E; Lencioni, A M; Pisani, N; Bertolini, L

    2015-06-01

    Atrial fibrillation (AF), the most common cardiac-arrhythmia in critical-care, has reached a high prevalence in hypertensive patients. Prevention of systemic-embolism is mandatory; unfortunately, evidence to support the treatment of comorbidities as coronary artery disease (CAD) that contribute to excess mortality is lacking, and the mechanism underlying the troponin-rise during AF without acute coronary syndrome (ACS) is unclear. This study investigates the relationship between CAD, stroke and outcomes in patients with troponin-rise and AF. Patients with a recent-onset AF and without severe comorbidities were enrolled. Baseline characteristics in those with troponin-rise versus those without were adjusted with propensity-score-matching for possible confounders. SPSS-software allowed estimation of the propensity-score using logistic-regression and specifying nearest-neighbor matching in prior-stroke, heart-rate, hypertension, TIMI-risk-score, GRACE-score, CHA2DS2Vasc-score. Patients with a troponin-rise or cardiovascular event (CVE) were considered for angiography. The primary endpoint was the composite of ACS, revascularization (with critical CAD>/ = 70%) and cardiac-death at the follow-up; the secondary endpoint was stroke. Out of 6203 AF patients without severe comorbidities, 3541 with recent-onset AF completed the study; 202(6%) showed a troponin-rise, 91(3%) a CVE. After matching no difference existed in baseline characteristics. On multivariate analysis, in the entire cohort, troponin-rise, know-CAD and hypertension were predictors of the endpoint, whereas only troponin-rise (Odd Ratio, OR: 10, Confidence Interval 95%, CI: 4-22, p  2 (OR 4, CI 2-9, p rise achieved the endpoint in 38(19%) and 43(1%), respectively (p  0.50 ng/L with 55% and 75%, respectively. Patients with a recent-onset AF and troponin-rise showed a high prevalence of CVE but not stroke, thus CAD might have a role in poor outcomes.

  8. A carbon nanotube screen-printed electrode for label-free detection of the human cardiac troponin T.

    Science.gov (United States)

    Silva, Bárbara V M; Cavalcanti, Igor T; Silva, Mízia M S; Dutra, Rosa F

    2013-12-15

    Label-free immunosensor based on amine-functionalized carbon nanotubes screen-printed electrode is described for detection of the cardiac troponin T, an important marker of acute myocardial infarction. The disposable sensor was fabricated by tightly squeezing an adhesive carbon ink containing carbon nanotubes onto a polyethylene terephthalate substrate forming a thin film. The use of carbon nanotubes increased the reproducibility and stability of the sensor, and the amine groups permitted nonrandom immobilization of antibodies against cardiac troponin T. Amperometric responses were obtained by differential pulse voltammetry in presence of a ferrocyanide/ferricyanide redox probe after troponin T incubation. The calibration curve indicated a linear response of troponin T between 0.0025 ng mL(-1) and 0.5 ng mL(-1), with a good correlation coefficient (r=0.995; p<0.0001, n=7). The limit of detection (0.0035 ng mL(-1) cardiac troponin T) was lower than any previously described by immunosensors and was comparable with conventional analytical methods. The high reproducibility and clinical range obtained using this immunosensor support its utility as a potential tool for point-of-care acute myocardial infarction diagnostic testing. © 2013 Elsevier B.V. All rights reserved.

  9. Clinical Characteristics and Outcomes of Patients with Myocardial Infarction, Myocardial Injury, and Nonelevated Troponins

    DEFF Research Database (Denmark)

    Sarkisian, Laura; Saaby, Lotte; Poulsen, Tina S

    2016-01-01

    BACKGROUND: Cardiac troponins have emerged as the preferred biomarkers for detecting myocardial necrosis and diagnosing myocardial infarction. However, current cardiac troponin assays do not discriminate between ischemic and nonischemic causes of myocardial cell death. Thus, when an increased...... troponin value is encountered in the absence of obvious myocardial ischemia, a careful search for other clinical conditions is crucial. METHODS: In 2010 to 2011, we prospectively studied hospitalized patients who had cardiac troponin I measured on clinical indication. An acute myocardial infarction...... was diagnosed in cases of a cardiac troponin I increase or decrease pattern with at least 1 value >30 ng/L (99th percentile) together with myocardial ischemia. Myocardial injury was defined as cardiac troponin I values >30 ng/L, but without signs or symptoms indicating overt cardiac ischemia. Patients with peak...

  10. Changes in the dynamics of the cardiac troponin C molecule explain the effects of Ca2+-sensitizing mutations.

    Science.gov (United States)

    Stevens, Charles M; Rayani, Kaveh; Singh, Gurpreet; Lotfalisalmasi, Bairam; Tieleman, D Peter; Tibbits, Glen F

    2017-07-14

    Cardiac troponin C (cTnC) is the regulatory protein that initiates cardiac contraction in response to Ca 2+ TnC binding Ca 2+ initiates a cascade of protein-protein interactions that begins with the opening of the N-terminal domain of cTnC, followed by cTnC binding the troponin I switch peptide (TnI SW ). We have evaluated, through isothermal titration calorimetry and molecular-dynamics simulation, the effect of several clinically relevant mutations (A8V, L29Q, A31S, L48Q, Q50R, and C84Y) on the Ca 2+ affinity, structural dynamics, and calculated interaction strengths between cTnC and each of Ca 2+ and TnI SW Surprisingly the Ca 2+ affinity measured by isothermal titration calorimetry was only significantly affected by half of these mutations including L48Q, which had a 10-fold higher affinity than WT, and the Q50R and C84Y mutants, each of which had affinities 3-fold higher than wild type. This suggests that Ca 2+ affinity of the N-terminal domain of cTnC in isolation is insufficient to explain the pathogenicity of these mutations. Molecular-dynamics simulation was used to evaluate the effects of these mutations on Ca 2+ binding, structural dynamics, and TnI interaction independently. Many of the mutations had a pronounced effect on the balance between the open and closed conformations of the TnC molecule, which provides an indirect mechanism for their pathogenic properties. Our data demonstrate that the structural dynamics of the cTnC molecule are key in determining myofilament Ca 2+ sensitivity. Our data further suggest that modulation of the structural dynamics is the underlying molecular mechanism for many disease mutations that are far from the regulatory Ca 2+ -binding site of cTnC. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  11. Prospective study of cardiac troponin I release in patients with upper gastrointestinal bleeding.

    Science.gov (United States)

    Iser, David M; Thompson, Alexander J V; Sia, Koon Ket; Yeomans, Neville D; Chen, Robert Y M

    2008-06-01

    The rate of cardiac injury in upper gastrointestinal hemorrhage is unclear. The aims of this study were to determine prospectively the risk of cardiac troponin I release and associated adverse cardiac events in patients with acute upper gastrointestinal hemorrhage. From January to September 2003, we prospectively studied patients with documented hematemesis and melena referred to the gastroenterology unit in a tertiary teaching hospital in Melbourne, Australia. Serial assays for cardiac troponin I were performed at 0, 12 and 24 h. Serial creatine kinase levels and electrocardiographs were also performed. Clinical and biochemical data were collected. The primary endpoint was a troponin level >0.5 microg/L within 24 h of recruitment. Various clinical variables were then compared between the groups of patients with or without troponin rise. A total of 156 patients were included in the study. The mean age was 67 years (range 19-96). There were 104 (67%) male patients. A troponin level of greater than 0.5 microg/L was found in 30/156 (19%); 126 (81%) patients had normal troponin levels. Age greater than 65 years, signs of hemodynamic instability at presentation, a recent history of cardiac disease, cardiovascular compromise following endoscopy, and re-bleeding were associated with troponin release. Upper gastrointestinal bleeding is associated with a risk of cardiac injury of up to 19%. Troponin assay could be used to screen for cardiac damage, especially in elderly patients who present with hemodynamic instability.

  12. High-sensitivity troponin assays for the early rule-out or diagnosis of acute myocardial infarction in people with acute chest pain: A systematic review and cost-effectiveness analysis

    NARCIS (Netherlands)

    M. Westwood (Marie); T. van Asselt (Thea); B.L.T. Ramaekers (Bram); P. Whiting (Penny); P. Thokala (Praveen); M.A. Joore (Manuela); N. Armstrong (Nigel); J. Ross (Janine); J.L. Severens (Hans); J. Kleijnen (Jos)

    2015-01-01

    textabstractBackground The primary indication for this assessment is the early rule-out of acute myocardial infarction (AMI) in people presenting with acute chest pain and suspected, but not confirmed, non-ST segment elevation myocardial infarction (NSTEMI). Cardiac troponins (cTns) I and T are used

  13. Diagnostic value of mean platelet volume (MPV) to troponin T inpatients with acute coronary syndrome

    Science.gov (United States)

    Aryanto, D.; Isnanta, R.; Safri, Z.; Hasan, R.

    2018-03-01

    Acute Coronary Syndrome (ACS) is used to describe the spectrum of coronary artery disease (CAD). Troponin T is the determinant of the most sensitive marker of ACS, but there aren’t all hospitals have this because of expensiveness. Mean Platelet Volume (MPV) is one of the components of a complete blood routine examination and relatively cheap as a marker in ACS. Determining the sensitivity and specificity of MPV in detecting cases of the acute coronary syndrome, 325 subjects’ medical records were from the period of July 2013 to June 2014; 228 ACS patients met the inclusion criteria. 228 subjects showed a risk factor for age ≥45years of more 195 (85.5%). 122 subjects with hypertension (53.5%) and subjects who smoked 118 (51.8%) that suffered most ACS. Subjects with risk factors for diabetes mellitus, obesity, menopause and dyslipidemia in this study was lower than non-diabetic 161 (70.6%), obese189 (82.9%), nonmenopause 196 (86%) and normal lipid 210 (92.1%). But there was norelation between risk factor with MPV and troponin T statistically. The results of diagnostic tests MPV for the evaluation of patients with ACS, sensitivity 92%, specificity 71%, positive predictive value 95% and negative predictive value 58%.

  14. Coronary atherosclerosis and adverse outcomes in patients with recent-onset atrial fibrillation and troponin rise.

    Science.gov (United States)

    Conti, Alberto; Angeli, Elena; Scorpiniti, Margherita; Alesi, Andrea; Trausi, Federica; Lazzeretti, Delia; Padeletti, Luigi; Gensini, Gian Franco

    2015-10-01

    The relationship between troponin and atrial fibrillation (AF) without acute coronary syndrome is still unclear. We sought to investigate the presence of coronary atherosclerosis and adverse outcomes in patients with AF. Consecutive patients with recent-onset AF and without severe comorbidities were enrolled between 2004 and 2013. Patients with a troponin rise or with adverse outcomes were considered for coronary angiography and revascularization when "critical" stenosis (≥70%) was recognized. Propensity score matching was performed to adjust for baseline characteristics; after matching, no differences existed between the groups of patients with or without troponin rise. The primary end point was the composite of acute coronary syndrome, revascularization, and cardiac death at 1- and 12-month follow-ups. Of 3627 patients enrolled, 3541 completed the study; 202 (6%) showed troponin rise; and 91 (3%), an adverse outcome. In the entire cohort, on multivariate analysis, the odds ratio for the occurrence of the primary end point of troponin rise was 14 (95% confidence interval [CI], 10-23; Prise was 10 (CI, 4-22; Prise achieved the primary end point in 38 (19%) and 43 (1%) patients, respectively (Prise showed higher prevalence of coronary atherosclerosis and adverse cardiac events. Stroke per se did not succeed in justifying the high morbidity. Thus, beyond stroke, coronary atherosclerosis might have a pivotal role in poor outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Prognostic importance of troponin T and creatine kinase after elective angioplasty

    NARCIS (Netherlands)

    Nienhuis, Mark B.; Ottervanger, Jan Paul; Dikkeschei, Bert; Suryapranata, Harry; de Boer, Menko-Jan; Dambrink, Jan-Henk E.; Hoorntje, Jan C. A.; van't Hof, Arnoud W. J.; Gosselink, Marcel; Zijlstra, Felix

    2007-01-01

    Background: The prognostic importance of elevated cardiac enzymes after elective percutaneous coronary intervention has been debated. Therefore, we performed a prospective observational study to evaluate the prognostic value of postprocedural rise of troponin T and creatine kinase. Methods: Troponin

  16. Analysis of troponin I gene polymorphisms and meat quality in ...

    African Journals Online (AJOL)

    Troponin I is one of myofibrillar proteins required for the calcium regulation of skeletal muscle contraction. The expression of both genes, TNNI1 and TNNI2, in troponin is muscle fibre specific and may affect meat quality traits. In this study, the PCR-RFLP method was applied to genotype 120 Mongcai pigs at three ...

  17. Molecular basis of calcium-sensitizing and desensitizing mutations of the human cardiac troponin C regulatory domain: a multi-scale simulation study.

    Directory of Open Access Journals (Sweden)

    Peter Michael Kekenes-Huskey

    Full Text Available Troponin C (TnC is implicated in the initiation of myocyte contraction via binding of cytosolic Ca²⁺ and subsequent recognition of the Troponin I switch peptide. Mutations of the cardiac TnC N-terminal regulatory domain have been shown to alter both calcium binding and myofilament force generation. We have performed molecular dynamics simulations of engineered TnC variants that increase or decrease Ca²⁺ sensitivity, in order to understand the structural basis of their impact on TnC function. We will use the distinction for mutants that are associated with increased Ca²⁺ affinity and for those mutants with reduced affinity. Our studies demonstrate that for GOF mutants V44Q and L48Q, the structure of the physiologically-active site II Ca²⁺ binding site in the Ca²⁺-free (apo state closely resembled the Ca²⁺-bound (holo state. In contrast, site II is very labile for LOF mutants E40A and V79Q in the apo form and bears little resemblance with the holo conformation. We hypothesize that these phenomena contribute to the increased association rate, k(on, for the GOF mutants relative to LOF. Furthermore, we observe significant positive and negative positional correlations between helices in the GOF holo mutants that are not found in the LOF mutants. We anticipate these correlations may contribute either directly to Ca²⁺ affinity or indirectly through TnI association. Our observations based on the structure and dynamics of mutant TnC provide rationale for binding trends observed in GOF and LOF mutants and will guide the development of inotropic drugs that target TnC.

  18. Establishment of colloid gold immunity chromatography assay for cardiac troponin I (cTnI)

    International Nuclear Information System (INIS)

    Wang Dezhi; Chen Jiying; Qin Lili; Zhao Baojian; Zhang Chunming

    2006-01-01

    Objective: To establish the colloid gold Immunity chromatography assay for cardiac troponin I. Methods: To purify cTnI from human cardiac muscle and immunize rabbit with it. cTnI antibody of rabbit anti-human cardiac muscle has been prepared and colloid gold immunity chromatography assay was established by using immunity chromatography technology. Results: Anti-serum titles of cTnI were 1:100000, Ka=2.38 x 10 9 L/mol; Methodological index: Sensitivity: 5 ng/ml; Specificity: cTnI is no cross-reaction with cTnT, cTnC and CK-MB. conclusion: The assay is highly specific, quick and simple. It can be widely used for the early diagnosis of AMI and scientific research. (authors)

  19. [Early detection of the cardiotoxicity induced by chemotherapy drug through two-dimensional speckle tracking echocardiography combined with high-sensitive cardiac troponin T].

    Science.gov (United States)

    Wang, W; Kang, Y; Shu, X H; Shen, X D; He, B

    2017-11-23

    Objective: To investigate the clinical value of two-dimensional speckle tracking echocardiography(2D-STE) combined with high-sensitive cardiac troponin T (hs-cTnT) in early detection of the cardiotoxicity induced by chemotherapy drug. Methods: Seventy-five non-Hodgkin's lymphoma patients who received the CHOP regimen were recruited in this study. Conventional echocardiography and 2D-STE were performed on these patients before chemotherapy, the second day after the third course of chemotherapy (during chemotherapy) and the second day after the last course of chemotherapy (after chemotherapy). The parameters included left ventricular ejection fraction (LVEF), global longitudinal strain (LS), global circumferential strain (CS) and global radial strain (RS). The serum hs-cTNT levels were tested simultaneously. Results: Three cycles of CHOP were completed in 30 patients and 6-8 cycles of CHOP were completed in 45 patients. The LVEF of 75 patients before, during and after chemotherapy was (63.8±2.6)%, (63.8±2.8)% and (64.0±3.3)%, respectively, without significant difference ( P =0.91). However, the LS of 75 patients before, during and after chemotherapy was (-18.5±1.7)%, (-16.5±1.9)% and (-16.0±1.6)%, respectively. The CS was (-20.9±2.9)%, (-19.3±3.5)% and (-19.2±3.2)%, respectively. The RS was (39.2±6.4)%, (35.3±5.2)% and (35.0±6.2)%, respectively. The hs-cTnT was (0.001 0±0.002 0)ng/ml, (0.006 3±0.008 9)ng/ml and (0.007 3±0.003 8)ng/ml, respectively. The LS, CS and RS were significantly decreased while hs-cTnT was significantly increased during chemotherapy when compared to those before chemotherapy (all of P chemotherapy were marginally different from those during chemotherapy (all of P >0.05). Moreover, T(LS-SD), T(CS-SD) and T(RS-SD) showed no significant difference before, during and after chemotherapy (all of P >0.05). The reduction of LS was positively associated with the enhancement of hs-cTnT after chemotherapy ( r =0.60, P effectively and

  20. Elevated Troponin Serum Levels in Adult Onset Still’s Disease

    Directory of Open Access Journals (Sweden)

    Carlo Umberto Manzini

    2015-01-01

    Full Text Available Adult onset Still’s disease (AOSD is a rare inflammatory systemic disease that occasionally may affect myocardium. Diagnosis is based on typical AOSD symptoms after the exclusion of well-known infectious, neoplastic, or autoimmune/autoinflammatory disorders. In the case of abrupt, recent onset AOSD, it could be particularly difficult to make the differential diagnosis and in particular to early detect the possible heart involvement. This latter event is suggested by the clinical history of the four patients described here, incidentally observed at our emergency room. All cases were referred because of acute illness (high fever, malaise, polyarthralgias, skin rash, and sore throat, successively classified as AOSD, and they presented abnormally high levels of serum troponin without overt symptoms of cardiac involvement. The timely treatment with steroids (3 cases or ibuprofen (1 case leads to the remission of clinicoserological manifestations within few weeks. These observations suggest that early myocardial injury might be underestimated or entirely overlooked in patients with AOSD; routine cardiac assessment including troponin evaluation should be mandatory in all patients with suspected AOSD.

  1. Molecular Defects in Cardiac Myofilament Ca2+-Regulation Due to Cardiomyopathy-Linked Mutations Can Be Reversed by Small Molecules Binding to Troponin

    Directory of Open Access Journals (Sweden)

    Alice Sheehan

    2018-03-01

    filaments. Many of these compounds were either pure re-couplers or pure desensitizers, indicating these properties are independent; moreover, re-coupling ability could be lost with small changes of compound structure, indicating the possibility of specificity. Small molecules that can re-couple may have therapeutic potential.HIGHLIGHTS- Inherited cardiomyopathies are common diseases that are currently untreatable at a fundamental level and therefore finding a small molecule treatment is highly desirable.- We have identified a molecular level dysfunction common to nearly all mutations: uncoupling of the relationship between troponin I phosphorylation and modulation of myofilament Ca2+-sensitivity, essential for normal responses to adrenaline.- We have identified a new class of drugs that are capable of both reducing Ca2+-sensitivity and/or recouping the relationship between troponin I phosphorylation and Ca2+-sensitivity.- The re-coupling phenomenon can be explained on the basis of a single mechanism that is testable.- Measurements with a wide range of small molecules of varying structures can indicate the critical molecular features required for recoupling and allows the prediction of other potential re-couplers.

  2. Molecular Defects in Cardiac Myofilament Ca2+-Regulation Due to Cardiomyopathy-Linked Mutations Can Be Reversed by Small Molecules Binding to Troponin.

    Science.gov (United States)

    Sheehan, Alice; Messer, Andrew E; Papadaki, Maria; Choudhry, Afnan; Kren, Vladimír; Biedermann, David; Blagg, Brian; Khandelwal, Anuj; Marston, Steven B

    2018-01-01

    . Many of these compounds were either pure re-couplers or pure desensitizers, indicating these properties are independent; moreover, re-coupling ability could be lost with small changes of compound structure, indicating the possibility of specificity. Small molecules that can re-couple may have therapeutic potential. HIGHLIGHTS - Inherited cardiomyopathies are common diseases that are currently untreatable at a fundamental level and therefore finding a small molecule treatment is highly desirable.- We have identified a molecular level dysfunction common to nearly all mutations: uncoupling of the relationship between troponin I phosphorylation and modulation of myofilament Ca 2+ -sensitivity, essential for normal responses to adrenaline.- We have identified a new class of drugs that are capable of both reducing Ca 2+ -sensitivity and/or recouping the relationship between troponin I phosphorylation and Ca 2+ -sensitivity.- The re-coupling phenomenon can be explained on the basis of a single mechanism that is testable.- Measurements with a wide range of small molecules of varying structures can indicate the critical molecular features required for recoupling and allows the prediction of other potential re-couplers.

  3. Association between Angiotensin-Converting Enzyme Inhibitors and Troponin in Acute Coronary Syndrome

    Directory of Open Access Journals (Sweden)

    Luiz Minuzzo

    2014-12-01

    Full Text Available Background: Cardiovascular disease is the leading cause of mortality in the western world and its treatment should be optimized to decrease severe adverse events. Objective: To determine the effect of previous use of angiotensin-converting enzyme inhibitors on cardiac troponin I measurement in patients with acute coronary syndrome without ST-segment elevation and evaluate clinical outcomes at 180 days. Methods: Prospective, observational study, carried out in a tertiary center, in patients with acute coronary syndrome without ST-segment elevation. Clinical, electrocardiographic and laboratory variables were analyzed, with emphasis on previous use of angiotensin-converting enzyme inhibitors and cardiac troponin I. The Pearson chi-square tests (Pereira or Fisher's exact test (Armitage were used, as well as the non-parametric Mann-Whitney's test. Variables with significance levels of 0.5 ng / mL were high blood glucose at admission (p = 0.0034 and ST-segment depression ≥ 0.5 mm in one or more leads (p = 0.0016. The use of angiotensin-converting inhibitors prior to hospitalization was associated with troponin ≤ 0.5 ng / mL (p = 0.0482. The C-statistics for this model was 0.77. Conclusion: This study showed a correlation between prior use of angiotensin-converting enzyme inhibitors and reduction in the myocardial necrosis marker troponin I in patients admitted for acute coronary syndrome without ST-segment elevation. However, there are no data available yet to state that this reduction could lead to fewer severe clinical events such as death and re-infarction at 180 days.

  4. Association of Elevated High Sensitivity Cardiac Troponin T(hs-cTnT) Levels with Hemorrhagic Transformation and 3-Month Mortality in Acute Ischemic Stroke Patients with Rheumatic Heart Disease in China.

    Science.gov (United States)

    Liu, Junfeng; Wang, Deren; Xiong, Yao; Liu, Bian; Hao, Zilong; Tao, Wendan; Liu, Ming

    2016-01-01

    Elevated levels of high sensitivity cardiac troponin T (hs-cTnT) occur in a substantial proportion of patients with acute ischemic stroke (AIS) and can predict poor outcome and mortality after stroke. Whether elevated hs-cTnT levels can also predict hemorrhagic transformation (HT) or prognosis in AIS patients with rheumatic heart disease (RHD) remains unclear. Data from the Chengdu Stroke Registry on consecutive AIS patients with RHD admitted to West China Hospital within 1 month of stroke onset from October 2011 to February 2014 were examined. Clinico-demographic characteristics, HT, functional outcomes and stroke recurrence were compared between patients with elevated hs-cTnT levels (≥14 ng/L) and patients with normal hs-cTnT levels (mortality and 3-month disability/mortality (all P≤0.029). After controlling for age, sex, hypertension, renal impairment and National Institutes of Health Stroke Scale score on admission, the risk of HT and 3-month mortality was, respectively, 4.0- and 5.5-fold higher in patients with elevated hs-cTnT levels than in patients with normal hs-cTnT levels. Elevated hs-cTnT levels are independently associated with HT and 3-month mortality in AIS patients with RHD. These results with a small cohort should be verified and extended in large studies.

  5. Prevalence and significance of troponin elevations in patients without acute coronary disease

    DEFF Research Database (Denmark)

    Vestergaard, Kirstine Roll; Jespersen, Camilla Bang; Arnadottir, Asthildur

    2016-01-01

    BACKGROUND: Cardiac troponin T and I are important diagnostic and prognostic markers in patients with acute coronary syndrome (ACS). Troponin elevations in various non-ACS scenarios have been documented, but few studies have been conducted on the general hospitalized population, none compared...

  6. Economic evaluation of the one-hour rule-out and rule-in algorithm for acute myocardial infarction using the high-sensitivity cardiac troponin T assay in the emergency department.

    Directory of Open Access Journals (Sweden)

    Apoorva Ambavane

    Full Text Available The 1-hour (h algorithm triages patients presenting with suspected acute myocardial infarction (AMI to the emergency department (ED towards "rule-out," "rule-in," or "observation," depending on baseline and 1-h levels of high-sensitivity cardiac troponin (hs-cTn. The economic consequences of applying the accelerated 1-h algorithm are unknown.We performed a post-hoc economic analysis in a large, diagnostic, multicenter study of hs-cTnT using central adjudication of the final diagnosis by two independent cardiologists. Length of stay (LoS, resource utilization (RU, and predicted diagnostic accuracy of the 1-h algorithm compared to standard of care (SoC in the ED were estimated. The ED LoS, RU, and accuracy of the 1-h algorithm was compared to that achieved by the SoC at ED discharge. Expert opinion was sought to characterize clinical implementation of the 1-h algorithm, which required blood draws at ED presentation and 1h, after which "rule-in" patients were transferred for coronary angiography, "rule-out" patients underwent outpatient stress testing, and "observation" patients received SoC. Unit costs were for the United Kingdom, Switzerland, and Germany. The sensitivity and specificity for the 1-h algorithm were 87% and 96%, respectively, compared to 69% and 98% for SoC. The mean ED LoS for the 1-h algorithm was 4.3h-it was 6.5h for SoC, which is a reduction of 33%. The 1-h algorithm was associated with reductions in RU, driven largely by the shorter LoS in the ED for patients with a diagnosis other than AMI. The estimated total costs per patient were £2,480 for the 1-h algorithm compared to £4,561 for SoC, a reduction of up to 46%.The analysis shows that the use of 1-h algorithm is associated with reduction in overall AMI diagnostic costs, provided it is carefully implemented in clinical practice. These results need to be prospectively validated in the future.

  7. Cardiac Troponin I, Creatine Phosphokinase and Myoglobine Levels in Preeclampsia

    Directory of Open Access Journals (Sweden)

    Ahmet Kale

    2005-01-01

    Full Text Available To evaluate minor myocardial injury in preeclamptic pregnancies by serum markers of cardiac troponin-I, creatine phosphokinase and myoglobine. Group I consisted of 45 preeclamptic pregnancies, Group 2 consisted of uncomplicated pregnancies. The groups were compared for maternal age, parity, mean troponin–I, creatine phosphokinase and myoglobine values. Student-t test were used in statistical analyses. Significance was accepted as p<0.05. Cardiac troponin-I levels were statistically significantly higher in preeclamptic pregnancies (0,97 ± 0,11ng/ml than control groups (0,12 ± 0.09 ng/ml (p<0.001. No statistically significant difference was found with mean levels of creatine phosphokinase and myoglobin levels between two groups. Higher values of troponin-I’in preeclamptic patients is thought to be a result of myocardial injury and associated with pregnancy-induced hypertension.

  8. Routine Troponin Measurements Are Unnecessary to Exclude Asymptomatic Coronary Events in Acute Ischemic Stroke Patients.

    Science.gov (United States)

    Ali, Farwa; Young, Jimmy; Rabinstein, Alejandro A; Flemming, Kelly D; Fugate, Jennifer E

    2016-05-01

    Obtaining serum troponin levels in every patient with acute stroke is recommended in recent stroke guidelines, but there is no evidence that these contribute positively to clinical care. We sought to determine the clinical significance of measuring troponin levels in acute ischemic stroke patients. We reviewed 398 consecutive patients with acute ischemic stroke at a large academic institution from 2010 to 2012. Troponin levels were measured as a result of protocol in place during part of the study period. The mean age was 70 years (standard deviation ±16 years) and 197 (49.5%) were men. Chronic kidney disease was present in 78 (19.6%), coronary artery disease in 107 (26.9%), and atrial fibrillation in 107 (26.9%). Serum troponin T was measured in 246 of 398 patients (61.8%). Troponin was elevated (>.01 ng/mL) at any point in 38 of 246 patients (15.5%) and was elevated in 28 patients at all 3 measurements (11.3% of those with troponin measured). Only 4 of 246 patients (1.6%) had a significant uptrend. Two were iatrogenic in the setting of hemodynamic augmentation using vasopressors to maintain cerebral perfusion. One case was attributed to stroke and chronic kidney disease and another case to heart failure from inflammatory fibrocalcific mitral valvular heart disease. Serum troponin elevation in patients with ischemic stroke is not usually caused by clinically significant acute myocardial ischemia unless iatrogenic in the setting of vasopressor administration. Serum troponin levels should be measured judicially, based on clinical context, rather than routinely in all stroke patients. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  9. Diagnosis of type 1 and type 2 myocardial infarction using a high-sensitivity cardiac troponin I assay with sex-specific 99th percentiles based on the third universal definition of myocardial infarction classification system.

    Science.gov (United States)

    Sandoval, Yader; Smith, Stephen W; Schulz, Karen M; Murakami, MaryAnn M; Love, Sara A; Nicholson, Jennifer; Apple, Fred S

    2015-04-01

    The frequency and characteristics of myocardial infarction (MI) subtypes per the Third Universal Definition of MI (TUDMI) classification system using high-sensitivity (hs) cardiac troponin assays with sex-specific cutoffs is not well known. We sought to describe the diagnostic characteristics of type 1 (T1MI) and type 2 (T2MI) MI using an hs-cardiac troponin I (hs-cTnI) assay with sex-specific cutoffs. A total of 310 consecutive patients with serial cTnI measurements obtained on clinical indication were studied with contemporary and hs-cTnI assays. Ninety-ninth percentile sex-specific upper reference limits (URLs) for the hs-cTnI assay were 16 ng/L for females and 34 ng/L for males. The TUDMI consensus recommendations were used to define and adjudicate MI based on each URL. A total of 127 (41%) patients had at least 1 hs-cTnI exceeding the sex-specific 99th percentiles, whereas 183 (59%) had hs-cTnI within the reference interval. Females had more myocardial injury related to supply/demand ischemia than males (39% vs 18%, P = 0.01), whereas males had more multifactorial or indeterminate injury (52% vs 33%, P = 0.05). By hs-cTnI, there were 32 (10%) acute MIs, among which 10 (3%) were T1MI and 22 (7%) were T2MI. T2MI represented 69% (22 out of 32) of all acute MIs, whereas T1MI represented 31% (10 out of 32). Ninety-five patients (31%) had an increased hs-cTnI above the 99th percentile but did not meet criteria for acute MI. The most common triggers for T2MI were tachyarrhythmias, hypotension/shock, and hypertension. By contemporary cTnI, more MIs (14 T1MI and 29 T2MI) were diagnosed. By contemporary cTnI, there were 43 MIs, 14 T1MI, and 29 T2MI. Fewer MI diagnoses were found with the hs-cTnI assay, contrary to the commonly accepted idea that hs-cTnI will lead to excessive false-positive diagnoses. © 2015 American Association for Clinical Chemistry.

  10. Mild troponin I elevation does not predict ischemia on myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Le Dung Ha

    2017-08-01

    Full Text Available IntroductionData are limited on the degree of mild troponin I elevation and clinical risk factors in predicting myocardial ischemia.MethodsHospitalized adult patients who underwent myocardial perfusion imaging (MPI from 2015 to 2016 at Rochester General Hospital and had mild troponin I elevation (>0.1 and <1.5 ng/mL were included. Predictors of outcomes were determined using logistic regression model.ResultsOne hundred and sixty-six patients with mild troponin I elevation who underwent MPI were followed. Mean age was 69.6 ± 12.5 years and 53.0% of the patients were female. Fourteen patients (8.4% presented with typical chest pain (CP, 60 patients (36.1% had atypical CP and 92 patients (55.4% had no CP on presentation. MPI was positive for ischemia in 45 patients (27.1%. There was no difference in peak troponin I level with ischemia versus no ischemia on MPI (0.34 ng/dL [0.13-0.69] vs. 0.23 ng/dL [0.14-0.50], p value 0.254. Atypical CP did not predict the presence of ischemia on MPI (odds ratio [OR] 1.97, 95% confidence interval [CI] 0.91-4.26. Coronary artery disease (CAD history (age and sex adjusted p value 0.013, diabetes (adjusted p value 0.036, creatinine ≥2 mg/dL (adjusted p value 0.019 and dialysis (adjusted p value 0.006 were statistically significant predictors of ischemia on MPI.ConclusionsIn patients presenting with mild troponin I elevation, peak troponin I level did not predict ischemia on MPI. The presence of CAD history, diabetes, elevated creatinine and dialysis were predictors of ischemia on MPI.

  11. Investigating the role of uncoupling of Troponin I phosphorylation from changes in myofibrillar Ca2+-sensitivity in the pathogenesis of Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Andrew Easton Messer

    2014-08-01

    Full Text Available Contraction in the mammalian heart is controlled by the intracellular Ca2+ concentration as it is in all striated muscle, but the heart has an additional signalling system that comes into play to increase heart rate and cardiac output during exercise or stress. β-adrenergic stimulation of heart muscle cells leads to release of cyclic-AMP and the activation of protein kinase A which phosphorylates key proteins in the sarcolemma, sarcoplasmic reticulum and contractile apparatus. Troponin I (TnI and Myosin Binding Protein C (MyBP-C are the prime targets in the myofilaments. TnI phosphorylation lowers myofibrillar Ca2+-sensitivity and increases the speed of Ca2+-dissociation and relaxation (lusitropic effect.Recent studies have shown that this relationship between Ca2+-sensitivity and TnI phosphorylation may be unstable. In familial cardiomyopathies, both dilated and hypertrophic (DCM and HCM, a mutation in one of the proteins of the thin filament often results in the loss of the relationship (uncoupling and blunting of the lusitropic response. For familial dilated cardiomyopathy in thin filament proteins it has been proposed that this uncoupling is causative of the phenotype. Uncoupling has also been found in human heart tissue from patients with hypertrophic obstructive cardiomyopathy as a secondary effect. Recently, it has been found that Ca2+-sensitizing drugs can promote uncoupling, whilst one Ca2+-desensitising drug Epigallocatechin 3-Gallate (EGCG can reverse uncoupling.We will discuss recent findings about the role of uncoupling in the development of cardiomyopathies and the molecular mechanism of the process.

  12. Effects of the whole-body cryotherapy on NTproBNP, hsCRP and troponin I in athletes.

    Science.gov (United States)

    Banfi, Giuseppe; Melegati, Gianluca; Barassi, Alessandra; d'Eril, Gianlodovico Melzi

    2009-11-01

    Whole-body cryotherapy refers to brief exposure to very cold air for treating symptoms of various illnesses. In sports medicine, whole-body cryotherapy is administered to improve recovery from muscular trauma. As specific studies are lacking, we measured cardiac markers in 10 top-level rugby players of the Italian National team before and after a 1-week course of daily sessions of whole-body cryotherapy. All subjects continued with the same training workload as that of the previous weeks. N-terminal pro B-type natriuretic peptide (NTproBNP) levels increased but remained within the normal range, whilst troponin I (TnI) and high sensitivity C-reactive protein (hsCRP) were unchanged. Whole-body cryotherapy did not impair cardiac function in this sample of elite athletes.

  13. Serial Measurement of High-Sensitivity Troponin I and Cardiovascular Outcomes in Patients With Type 2 Diabetes Mellitus in the EXAMINE Trial (Examination of Cardiovascular Outcomes With Alogliptin Versus Standard of Care).

    Science.gov (United States)

    Cavender, Matthew A; White, William B; Jarolim, Petr; Bakris, George L; Cushman, William C; Kupfer, Stuart; Gao, Qi; Mehta, Cyrus R; Zannad, Faiez; Cannon, Christopher P; Morrow, David A

    2017-05-16

    We aimed to describe the relationship between changes in high-sensitivity cardiac troponin I (hsTnI) and cardiovascular outcomes. The EXAMINE trial (Examination of Cardiovascular Outcomes With Alogliptin Versus Standard of Care) was a phase IIIb clinical outcomes trial designed to evaluate the cardiovascular safety of alogliptin, a nonselective dipeptidyl peptidase 4 inhibitor. Patients with type 2 diabetes mellitus, glycohemoglobin between 6.5% and 11% (or between 7% and 11% if they were on insulin), and a recent acute coronary syndrome (between 15 and 90 days before randomization) were eligible for the trial. hsTnI was measured using the Abbott ARCHITECT assay at baseline and 6 months in patients randomized in the EXAMINE trial. This analysis was restricted to patients randomized ≥30 days after qualifying acute coronary syndrome to mitigate the potential for persistent hsTnI elevation after acute coronary syndrome (n=3808). The primary end point of the trial was cardiovascular death, myocardial infarction, or stroke. Cardiovascular death or heart failure was a prespecified, adjudicated secondary end point. At baseline, hsTnI was detectable (≥1.9 ng/L) in 93% of patients and >99 th percentile upper reference limit in 16%. There was a strong relationship between increasing hsTnI, both at baseline and 6 months, and the incidence of cardiovascular events through 24 months ( P diabetes mellitus without clinically recognized events had dynamic or persistently elevated values and were at high risk of recurrent events. hsTnI may have a role in personalizing preventive strategies in patients with diabetes mellitus based on risk. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00968708. © 2017 American Heart Association, Inc.

  14. IN SEARCH OF THE MISSING LINK: SERUM LIPID PROFILE, TROPONIN T AND ACUTE CORONARY SYNDROME.

    OpenAIRE

    Basabdatta Samanta; Bharti Kawatra; Sandip

    2014-01-01

    Acute coronary syndrome is one of the leading causes of morbidity and mortality worldwide , hyperlipidemias being a major predisposing factor. Cardiac Troponin T (cTnT) is one of the most sensitive and specific biomarkers of myocardial injury. The aim of the study was to evaluate the relationship among TnT levels and lipid profiles of different age groups of patients with ACS , and to determine if any the association of age with lipid profile and TnT levels. The ...

  15. Consequences of implementing a cardiac troponin assay with improved sensitivity at Swedish coronary care units: an analysis from the SWEDEHEART registry.

    Science.gov (United States)

    Eggers, Kai M; Lindahl, Bertil; Melki, Dina; Jernberg, Tomas

    2016-08-07

    Cardiac troponin (cTn) assays with improved sensitivity are increasingly utilized for the assessment of patients admitted because of suspected acute coronary syndrome (ACS). However, data on the clinical consequences of the implementation of such assays are limited. In a retrospective register-based study (37 710 coronary care unit admissions; SWEDEHEART registry), we compared the case mix, the use of diagnostic procedures, treatments, and 1-year all-cause mortality 1 year before the implementation of a cTn assay with improved sensitivity (study period 1) and 1 year thereafter (study period 2). During study period 2, more at-risk patients were admitted and more patients had cTn levels above the myocardial infarction cut-off (ACS patients +13.1%; non-ACS patients +160.1%). cTn levels above this cut-off exhibited stronger associations with mortality risk in study period 2 (adjusted HR 4.45 [95% confidence interval, CI, 3.36-5.89]) compared with period 1 (adjusted HR 2.43 [95% CI 2.11-2.80]), similar as for the cTn ratio relative to the respective 99th percentile. While there was no multivariable-adjusted increase in the use of diagnostic procedures, significant trends towards more differentiated treatment depending on the cause of cTn elevation, i.e. ACS or non-ACS, were noted. The implementation of a cTn assay with improved sensitivity was associated with an increase in the number of patients who due to their cTn-status were identified as suitable for beneficial therapies. There was no inappropriate increase in hospital resource utilization. As such, cTn assays with improved sensitivity provide an opportunity to improve the clinical management of patients with suspected ACS. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  16. The Veracity of Troponin Test Requests for Patients Presenting to the Emergency Department with Chest Pain; A Clinical Audit

    Directory of Open Access Journals (Sweden)

    Anita Sabzghabaei

    2017-10-01

    Full Text Available Introduction: Troponin test is one of the methods for diagnosing acute coronary syndrome, but the overuse and misuse of this test has increased the costs imposed on the health system and the patients. Objective: The present study was conducted to investigate the veracity of troponin test requests for patients presenting to an emergency department with chest pain and examine the effectiveness of training emergency medicine assistants in reducing unnecessary and inappropriate requests in emergency departments. Methods: This clinical audit was conducted in the emergency department of Imam Hossein Hospital, Tehran, Iran, in 2014. Sampling was carried out using the census method and all the cases presenting to the emergency department for whom a troponin test was requested by the emergency medical assistants were included in the research. First, the veracity of the current troponin test requests was assessed; then, training was given to the personnel, and the veracity of the troponin test requests was once again verified after the training was completed. The rate of veracious troponin requests for the patients was measured based on two factors, including the interval between the patients’ admission and the troponin test request, and the interval between the onset of pain and the troponin test request. The veracity of the troponin test request was compared before and after training using the Phi test and Cramer’s V test in IBM SPSS-21. Results: This study examined a total of 500 patients (250 before training and 250 after, who had a mean age of 57.65±18.15 years, including 51.6% men. Significant differences were observed between the mean time of the patients’ admission and the overall and post-training troponin test results (P=0.000, and also between the mean time of the onset of pain and the overall and post-training troponin test results (P=0.000. The number of positive troponin test results did not differ significantly between the patients

  17. Peptide Functionalized Gold Nanorods for the Sensitive Detection of a Cardiac Biomarker Using Plasmonic Paper Devices (Postprint)

    Science.gov (United States)

    2015-11-10

    Albumin to saturate the non-specific binding sites on the paper substrate prior to troponin exposure. For testing the biosensor, troponin of various...AFRL-RX-WP-JA-2016-0191 PEPTIDE FUNCTIONALIZED GOLD NANORODS FOR THE SENSITIVE DETECTION OF A CARDIAC BIOMARKER USING PLASMONIC PAPER ...SENSITIVE DETECTION OF A CARDIAC BIOMARKER USING PLASMONIC PAPER DEVICES (POSTPRINT) 5a. CONTRACT NUMBER FA8650-15-D-5405-0001 5b. GRANT NUMBER 5c

  18. Cardiac troponin I (CTnI level among children with epileptic seizures

    Directory of Open Access Journals (Sweden)

    Ahmed Anwer Attia Khattab

    2014-09-01

    Conclusion: Cardiac troponin I is a perfect tool for early detection of cases with myocardial dysfunction in epileptic patients – cardiac troponin I is significantly increased in children with epilepsy especially the complicated epilepsy. Cardiac injury in epileptic children is more common in patients with early onset epilepsy, positive prenatal problem, idiopathic epilepsy, abnormal imaging and EEG – elevated TnI levels may be of value in assessing the severity and eventual outcome and mortality risk of the disease in children with epilepsy.

  19. Frequency and significance of troponin T elevation in acute ischemic stroke

    DEFF Research Database (Denmark)

    Jensen, Jesper K.; Kristensen, Søren R.; Bak, Søren

    2007-01-01

    Elevated levels of troponin have been reported in patients with acute ischemic stroke. In this prospective study, the prevalence and characteristics of troponin elevation were examined in 244 patients with acute ischemic stroke but without overt ischemic heart disease. Troponin T (TnT) and creatine...... for a mean of 19 +/- 7 months, with all-cause mortality as the clinical end point. Elevated levels of TnT (>0.03 micro g/L) and creatine kinase-MB (> or =10 micro g/L) were observed in 10% and 9% of patients, respectively. Patients with elevated TnT had higher frequencies of heart and/or renal failure....... Perfusion abnormalities on myocardial perfusion scintigraphy at rest were not more frequent or pronounced in patients with TnT levels of > or =0.10 micro g/L than in the control group. Only 7 patients (3%) had elevations of TnT or creatine kinase-MB and electrocardiographic changes suggesting acute...

  20. A randomized cross-over study of the acute effects of running 5 km on glucose, insulin, metabolic rate, cortisol and Troponin T.

    Science.gov (United States)

    Keselman, Boris; Vergara, Marta; Nyberg, Sofia; Nystrom, Fredrik H

    2017-01-01

    We aimed to study the impact by running 5 km, at maximal speed, on the normal variations of metabolic variables related to glucose, insulin, insulin sensitivity, cortisol, glucagon, Troponin T and metabolic rate. Five women and 12 men 25.7±5.2 years of age with a body-mass-index of 22.5±2.3 kg/m2 where recruited to run 5 km at individual maximal speed in the morning, and to a corresponding day of rest, followed by standardized breakfast and lunch meals. Blood sampling and measurement of indirect calorimetry were done before and after meals. The participants were randomized regarding the order of the two trial-days in this cross-over study. Insulin and cortisol levels were higher, and insulin sensitivity was lower, on the race-day compared with the day of rest (linear mixed model: pdays (p = 0.29 and p = 0.53, respectively). When analyzing specific time-points we found that glucose increased from 5.01±0.37 mmol/l to 6.36 ± 1.3 mmol/l, pindex of serum sensitivity, 1/(log10insulin+log10glucose), was lowered post-race, p<0.0001. Serum cortisol levels increased from 408±137 nmol/l to 644±171 nmol/l, p<0.0001, post-race while serum glucagon levels were unaffected. Troponin T was detectable in serum post-race in 12 out of the 17 participants and reached or surpassed the clinical reference level of 15 ng/l in three subjects. Post-race electrocardiograms displayed no pathologies. Relatively short running-races can apparently induce a reduction in insulin sensitivity that is not fully compensated by concomitantly increased insulin secretion intended to ensure euglycemia. Since also Troponin T was detected in plasma in a majority of the participants, our data suggest that it is possible to induce considerable metabolic stress by running merely 5 km, when striving for maximal speed.

  1. Functional effects of the DCM mutant Gly159Asp troponin C in skinned muscle fibres

    DEFF Research Database (Denmark)

    Preston, Laura C; Lipscomb, Simon; Robinson, Paul

    2006-01-01

    We recently reported a dilated cardiomyopathy (DCM) causing mutation in a novel disease gene, TNNC1, which encodes cardiac troponin C (TnC). We have determined how this mutation, Gly159Asp, affects contractile regulation when incorporated into muscle fibres. Endogenous troponin in rabbit skinned...

  2. Multiple Species Comparison of Cardiac Troponin T and Dystrophin: Unravelling the DNA behind Dilated Cardiomyopathy.

    Science.gov (United States)

    England, Jennifer; Loughna, Siobhan; Rutland, Catrin Sian

    2017-07-07

    Animals have frequently been used as models for human disorders and mutations. Following advances in genetic testing and treatment options, and the decreasing cost of these technologies in the clinic, mutations in both companion and commercial animals are now being investigated. A recent review highlighted the genes associated with both human and non-human dilated cardiomyopathy. Cardiac troponin T and dystrophin were observed to be associated with both human and turkey (troponin T) and canine (dystrophin) dilated cardiomyopathies. This review gives an overview of the work carried out in cardiac troponin T and dystrophin to date in both human and animal dilated cardiomyopathy.

  3. Continuous cardiac troponin I release in Fabry disease.

    Science.gov (United States)

    Feustel, Andreas; Hahn, Andreas; Schneider, Christian; Sieweke, Nicole; Franzen, Wolfgang; Gündüz, Dursun; Rolfs, Arndt; Tanislav, Christian

    2014-01-01

    Fabry disease (FD) is a rare lysosomal storage disorder also affecting the heart. The aims of this study were to determine the frequency of cardiac troponin I (cTNI) elevation, a sensitive parameter reflecting myocardial damage, in a smaller cohort of FD-patients, and to analyze whether persistent cTNI can be a suitable biomarker to assess cardiac dysfunction in FD. cTNI values were determined at least twice per year in 14 FD-patients (6 males and 8 females) regularly followed-up in our centre. The data were related to other parameters of heart function including cardiac magnetic resonance imaging (cMRI). Three patients (21%) without specific vascular risk factors other than FD had persistent cTNI-elevations (range 0.05-0.71 ng/ml, normal: gadolinium enhancement (LGE) in all three individuals with cTNI values ≥0.01, while none of the 11 patients with cTNI <0.01 showed a pathological enhancement (p<0.01). Two subjects with increased cTNI-values underwent coronary angiography, excluding relevant stenoses. A myocardial biopsy performed in one during this procedure demonstrated substantial accumulation of globotriaosylceramide (Gb3) in cardiomyocytes. Continuous cTNI elevation seems to occur in a substantial proportion of patients with FD. The high accordance with LGE, reflecting cardiac dysfunction, suggests that cTNI-elevation can be a useful laboratory parameter for assessing myocardial damage in FD.

  4. Risk stratification in stable coronary artery disease is possible at cardiac troponin levels below conventional detection and is improved by use of N-terminal pro-B-type natriuretic peptide

    DEFF Research Database (Denmark)

    Lyngbæk, Stig; Winkel, Per; Gøtze, Jens P

    2014-01-01

    AIMS: Low prevalence of detectable cardiac troponin in healthy people and low-risk patients previously curtailed its use. With a new high-sensitive cardiac troponin assay (hs-cTnT), concentrations below conventional detection may have prognostic value, notably in combination with N-terminal pro......-B-type natriuretic peptide (NT-pro-BNP). METHODS AND RESULTS: Biomarker concentrations were determined from serum obtained at enrolment in the CLARICOR trial involving 4197 patients with stable coronary artery disease (CAD) followed for 2.6 years. Serum hs-cTnT was detectable (above 3 ng/l) in 78% and above...... the conventional 99th percentile (13.5 ng/l) in 23%. Across all levels of hs-cTnT there was a graded increase in the risk of cardiovascular death after adjustment for known prognostic indicators: hazard ratio (HR) per unit increase in the natural logarithm of the hs-cTnT level, 1.49; 95% confidence interval (CI...

  5. Impact of high-intensity interval training and moderate-intensity continuous training on resting and postexercise cardiac troponin T concentration.

    Science.gov (United States)

    Nie, Jinlei; Zhang, Haifeng; Kong, Zhaowei; George, Keith; Little, Jonathan P; Tong, Tomas K; Li, Feifei; Shi, Qingde

    2018-03-01

    What is the central question of this study? Does exercise training impact resting and postexercise cardiac troponin T (cTnT) concentration? What is the main finding and its importance? This randomized controlled intervention study demonstrated that 12 weeks of either high-intensity interval training or moderate-intensity continuous training largely abolished the exercise-induced elevation in cTnT when exercise was performed at the same absolute intensity. There was no impact of training on resting cTnT or postexercise appearance of cTnT when exercise was performed at the same relative intensity. These findings provide new information that might help clinicians with decision-making in relationship to basal and postexercise values of cTnT in individuals with different training status. We evaluated the influence of 12 weeks of high-intensity interval training [HIIT; repeated 4 min cycling at 90% of maximal oxygen uptake (V̇O2max) interspersed with 3 min rest, 200-300 kJ per session, 3 or 4 days each week] and work-equivalent moderate-intensity continuous training (MICT; continuous cycling at 60% V̇O2max) on resting cardiac troponin T (cTnT) and the appearance of exercise-induced cTnT. Forty-eight sedentary obese young women were randomly assigned to HIIT, MICT or a control group. The V̇O2max and body composition were measured before and after training. At baseline, cTnT was assessed using a high-sensitivity assay at rest and immediately, 2 and 4 h after 45 min cycling at 60% V̇O2max. After a 12 week training period, cTnT was assessed before and after 45 min cycling at the same relative and absolute intensities as before training. Training led to higher V̇O2max and lower fat mass in both HIIT and MICT groups (all P training, cTnT was significantly elevated in all three groups (by 35-118%, all P training, both resting and postexercise cTnT concentrations (same relative intensity) were similar to pretraining values. In contrast, postexercise cTnT (same

  6. Multiple Species Comparison of Cardiac Troponin T and Dystrophin: Unravelling the DNA behind Dilated Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Jennifer England

    2017-07-01

    Full Text Available Animals have frequently been used as models for human disorders and mutations. Following advances in genetic testing and treatment options, and the decreasing cost of these technologies in the clinic, mutations in both companion and commercial animals are now being investigated. A recent review highlighted the genes associated with both human and non-human dilated cardiomyopathy. Cardiac troponin T and dystrophin were observed to be associated with both human and turkey (troponin T and canine (dystrophin dilated cardiomyopathies. This review gives an overview of the work carried out in cardiac troponin T and dystrophin to date in both human and animal dilated cardiomyopathy.

  7. Drug-Induced Rhabdomyolysis with Elevated Cardiac Troponin T

    DEFF Research Database (Denmark)

    Egholm, Gro; Pareek, Manan

    2015-01-01

    for myocardial injury. This case report describes a 48-year-old woman, who, two years after cardiac transplantation, presented with rhabdomyolysis. During the course of the disease, her troponin T level was elevated on repeated occasions, but other definitive evidence of myocardial injury was not found...

  8. High-NaCl Diet Aggravates Cardiac Injury in Rats with Adenine-Induced Chronic Renal Failure and Increases Serum Troponin T Levels

    DEFF Research Database (Denmark)

    Kashioulis, Pavlos; Hammarsten, Ola; Marcussen, Niels

    2016-01-01

    AIMS: To examine the effects of 2 weeks of high-NaCl diet on left ventricular (LV) morphology and serum levels of cardiac troponin T (cTnT) in rats with adenine-induced chronic renal failure (ACRF). METHODS: Male Sprague-Dawley rats either received chow containing adenine or were pair......-fed an identical diet without adenine [controls (C)]. Approximately 10 weeks after the beginning of the study, the rats were randomized to either remain on a normal NaCl diet (NNa; 0.6%) or to be switched to high-NaCl chow (HNa; 4%) for 2 weeks, after which acute experiments were performed. RESULTS: Rats with ACRF...... showed statistically significant increases (p rats (p

  9. Usefulness of the troponin-ejection fraction product to differentiate stress cardiomyopathy from ST-segment elevation myocardial infarction.

    Science.gov (United States)

    Nascimento, Francisco O; Yang, Solomon; Larrauri-Reyes, Maiteder; Pineda, Andres M; Cornielle, Vertilio; Santana, Orlando; Heimowitz, Todd B; Stone, Gregg W; Beohar, Nirat

    2014-02-01

    The presentation of stress cardiomyopathy (SC) with nonobstructive coronary artery disease mimics that of ST-segment elevation myocardial infarction (STEMI) due to coronary occlusion. No single parameter has been successful in differentiating the 2 entities. We thus sought to develop a noninvasive clinical tool to discriminate between these 2 conditions. We retrospectively reviewed 59 consecutive cases of SC at our institution from July 2005 through June 2011 and compared those with 60 consecutives cases of angiographically confirmed STEMI treated with primary percutaneous coronary intervention in the same period. All patients underwent acute echocardiography, and the peak troponin I level was determined. The troponin-ejection fraction product (TEFP) was derived by multiplying the peak troponin I level and the echocardiographically derived left ventricular ejection fraction. Comparing the SC and STEMI groups, the mean left ventricular ejection fraction at the time of presentation was 30 ± 9% versus 44 ± 11%, respectively (p statistic 0.91 ± 0.02, p <0.001). In conclusion, for patients not undergoing emergent angiography, the TEFP may be used with high accuracy to differentiate SC with nonobstructive coronary artery disease from true STEMI due to coronary occlusion. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Pim-1 Kinase Phosphorylates Cardiac Troponin I and Regulates Cardiac Myofilament Function

    Directory of Open Access Journals (Sweden)

    Ni Zhu

    2018-03-01

    Full Text Available Background/Aims: Pim-1 is a serine/threonine kinase that is highly expressed in the heart, and exerts potent cardiac protective effects through enhancing survival, proliferation, and regeneration of cardiomyocytes. Its myocardial specific substrates, however, remain unknown. In the present study, we aim to investigate whether Pim-1 modulates myofilament activity through phosphorylation of cardiac troponin I (cTnI, a key component in regulating myofilament function in the heart. Methods: Coimmunoprecipitation and immunofluorescent assays were employed to investigate the interaction of Pim-1 with cTnI in cardiomyocytes. Biochemical, site directed mutagenesis, and mass spectrometric analyses were utilized to identify the phosphorylation sites of Pim1 in cTnI. Myofilament functional assay using skinned cardiac fiber was used to assess the effect of Pim1-mediated phosphorylation on cardiac myofilament activity. Lastly, the functional significance of Pim1-mediated cTnI in heart disease was determined in diabetic mice. Results: We found that Pim-1 specifically interacts with cTnI in cardiomyocytes and this interaction leads to Pim1-mediated cTnI phosphorylation, predominantly at Ser23/24 and Ser150. Furthermore, our functional assay demonstrated that Pim-1 induces a robust phosphorylation of cTnI within the troponin complex, thus leading to a decreased Ca2+ sensitivity. Insulin-like growth factor 1 (IGF-1, a peptide growth factor that has been shown to stimulate myocardial contractility, markedly induces cTnI phosphorylation at Ser23/24 and Ser150 through increasing Pim-1 expression in cardiomyocytes. In a high-fat diabetic mice model, the expression of Pim1 in the heart is significantly decreased, which is accompanied by a decreased phosphorylation of cTnI at Ser23/24 and Ser150, further implicating the pathological significance of the Pim1/cTnI axis in the development of diabetic cardiomyopathy. Conclusion: Our results demonstrate that Pim-1 is a

  11. Continuous cardiac troponin I release in Fabry disease.

    Directory of Open Access Journals (Sweden)

    Andreas Feustel

    Full Text Available Fabry disease (FD is a rare lysosomal storage disorder also affecting the heart. The aims of this study were to determine the frequency of cardiac troponin I (cTNI elevation, a sensitive parameter reflecting myocardial damage, in a smaller cohort of FD-patients, and to analyze whether persistent cTNI can be a suitable biomarker to assess cardiac dysfunction in FD.cTNI values were determined at least twice per year in 14 FD-patients (6 males and 8 females regularly followed-up in our centre. The data were related to other parameters of heart function including cardiac magnetic resonance imaging (cMRI.Three patients (21% without specific vascular risk factors other than FD had persistent cTNI-elevations (range 0.05-0.71 ng/ml, normal: <0.01. cMRI disclosed late gadolinium enhancement (LGE in all three individuals with cTNI values ≥0.01, while none of the 11 patients with cTNI <0.01 showed a pathological enhancement (p<0.01. Two subjects with increased cTNI-values underwent coronary angiography, excluding relevant stenoses. A myocardial biopsy performed in one during this procedure demonstrated substantial accumulation of globotriaosylceramide (Gb3 in cardiomyocytes.Continuous cTNI elevation seems to occur in a substantial proportion of patients with FD. The high accordance with LGE, reflecting cardiac dysfunction, suggests that cTNI-elevation can be a useful laboratory parameter for assessing myocardial damage in FD.

  12. MIPs-graphene nanoplatelets-MWCNTs modified glassy carbon electrode for the determination of cardiac troponin I.

    Science.gov (United States)

    Ma, Ya; Shen, Xiao-Lei; Wang, Hai-Shui; Tao, Jia; Huang, Jian-Zhi; Zeng, Qiang; Wang, Li-Shi

    2017-03-01

    An electrochemical sensor with high selectivity in addition to sensitivity was developed for the determination of cardiac troponin I (cTnI), based on the modification of cTnI imprinted polymer film on a glassy carbon electrode (GCE). The sensor was fabricated by layer-by-layer assembled graphene nanoplatelets (GS), multiwalled carbon nanotubes (MWCNTs), chitosan (CS), glutaraldehyde (GA) composites, which can increase the electronic transfer rate and the active surface area to capture a larger number of antigenic proteins. MWCNTs/GS based imprinted polymers (MIPs/MWCNTs/GS) were synthesized by means of methacrylic acid (MAA) as the monomer, ethylene glycol dimethacrylate (EGDMA) as the cross linker α,α'-azobisisobutyronitrile (AIBN) as the initiator and cTnI as the template. In comparison with conventional methods, the proposed electrochemical sensor is highly sensitive for cTnI, providing a better linear response range from 0.005 to 60 ng cm -3 and a lower limit of detection (LOD) of 0.0008 ng cm -3 under optimal experimental conditions. In addition, the electrochemical sensor exhibited good specificity, acceptable reproducibility and stability. Moreover, satisfactory results were obtained in real human serum samples, indicating that the developed method has the potential to find application in clinical detection of cTnI as an alternative approach. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Troponin elevation in subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Ioannis N. Mavridis

    2015-03-01

    Full Text Available Troponin (tr elevation in aneurysmal subarachnoid hemorrhage (SAH patients is often difficult to be appropriately assessed by clinicians, causing even disagreements regarding its management between neurosurgeons and cardiologists. The purpose of this article was to review the literature regarding the clinical interpretation of tr elevation in SAH. We searched for articles in PubMed using the key words: “troponin elevation” and “subarachnoid hemorrhage”. All of them, as well as relative neurosurgical books, were used for this review. Some type of cardiovascular abnormality develops in most SAH patients. Neurogenic stunned myocardium is a frequent SAH complication, due to catecholamine surge which induces cardiac injury, as evidenced by increased serum tr levels, electrocardiographic (ECG changes and cardiac wall motion abnormalities. Tr elevation, usually modest, is an early and specific marker for cardiac involvement after SAH and its levels peak about two days after SAH. Cardiac tr elevation predictors include poor clinical grade, intraventricular hemorrhage, loss of consciousness at ictus, global cerebral edema, female sex, large body surface area, lower systolic blood pressure, higher heart rate and prolonged Q-Tc interval. Elevated tr levels are associated with disability and death (especially tr >1 μg/L, worse neurological grade, systolic and diastolic cardiac dysfunction, pulmonary congestion, longer intensive care unit stay and incidence of vasospasm. Tr elevation is a common finding in SAH patients and constitutes a rightful cause of worry about the patients' cardiac function and prognosis. It should be therefore early detected, carefully monitored and appropriately managed by clinicians.

  14. Association of Elevated High Sensitivity Cardiac Troponin T(hs-cTnT Levels with Hemorrhagic Transformation and 3-Month Mortality in Acute Ischemic Stroke Patients with Rheumatic Heart Disease in China.

    Directory of Open Access Journals (Sweden)

    Junfeng Liu

    Full Text Available Elevated levels of high sensitivity cardiac troponin T (hs-cTnT occur in a substantial proportion of patients with acute ischemic stroke (AIS and can predict poor outcome and mortality after stroke. Whether elevated hs-cTnT levels can also predict hemorrhagic transformation (HT or prognosis in AIS patients with rheumatic heart disease (RHD remains unclear.Data from the Chengdu Stroke Registry on consecutive AIS patients with RHD admitted to West China Hospital within 1 month of stroke onset from October 2011 to February 2014 were examined. Clinico-demographic characteristics, HT, functional outcomes and stroke recurrence were compared between patients with elevated hs-cTnT levels (≥14 ng/L and patients with normal hs-cTnT levels (<14 ng/L.The final analysis involved 84 patients (31 males; mean age, 61.6±12.2 years, of whom serum hs-cTnT levels were elevated in 58.3%. Renal impairment was independently associated with elevated hs-cTnT levels (OR 4.184, 95%CI 1.17 to 15.01, P = 0.028, and patients with elevated hs-cTnT levels were at significantly higher risk of HT, 3-month mortality and 3-month disability/mortality (all P≤0.029. After controlling for age, sex, hypertension, renal impairment and National Institutes of Health Stroke Scale score on admission, the risk of HT and 3-month mortality was, respectively, 4.0- and 5.5-fold higher in patients with elevated hs-cTnT levels than in patients with normal hs-cTnT levels.Elevated hs-cTnT levels are independently associated with HT and 3-month mortality in AIS patients with RHD. These results with a small cohort should be verified and extended in large studies.

  15. Performance characteristics of loci method for measuring cardiac troponin I on the dimension EXL

    Directory of Open Access Journals (Sweden)

    José L. Martín Calderón

    2015-04-01

    Full Text Available Objective: To define the performance characteristics of the LOCI® method for cardiac troponin I on the Dimension EXL system. Designs and methods: Three different levels of commercial control (mean concentrations 0.426, 1.42, and 18.64 µg/L were used for the imprecision study, quantifying separately within-run and between-run over 20 days. The limit of blank (LoB and limit of detection (LoD were assessed with 20 replicates of a sample without troponin I. Linearity was assessed by regression analysis. In addition, we studied inaccuracy, carry-over and limit of quantitation and conducted a method comparison with the Stratus CS (n=69. The reference interval was determined in 146 healthy blood donors using non-parametric method. Results: The within-run imprecision (coefficient of variation [CV], % obtained at each level was 2.4, 1.4% and 2.2%, while the between-run imprecision (CV,% was 3.3%, 2.9% and 2.5%. Total imprecision was 4.06%, 3.3% and 3.4% for each control level. The limit of quantitation which corresponds to the troponin I concentration at which CV=10% was 0.05 µg/L. Method comparison with the Stratus CS assay produced the equation: Dimension EXL=−0.002698+1.0233⁎(Stratus CS with a confidence interval from −0.01562 to 0.00626 for the intercept and (0.979 to 1.0875 for the slope. The 99th percentile obtained for the reference population was 0.047 µg/L. Conclusions: The LOCI method for cardiac troponin I on the Dimension EXL meets all guidelines recommended criteria referring to limit of quantitation, imprecision and shows excellent transferability with the Stratus CS method. Keywords: Cardiac troponin, LOCI, Dimension EXL

  16. Multiple species comparison of cardiac troponin T and dystrophin: unravelling the DNA behind dilated cardiomyopathy

    OpenAIRE

    England, Jennifer; Loughna, Siobhan; Rutland, Catrin S.

    2017-01-01

    Animals have frequently been used as models for human disorders and mutations. Following advances in genetic testing and treatment options, and the decreasing cost of these technologies in the clinic, mutations in both companion and commercial animals are now being investigated. A recent review highlighted the genes associated with both human and non-human dilated cardiomyopathy. Cardiac troponin T and dystrophin were observed to be associated with both human and turkey (troponin T) and canin...

  17. Obstructive sleep apnea: no independent association to troponins.

    Science.gov (United States)

    Hall, Trygve Sørdahl; Herrscher, Tobias; Jarolim, Petr; Fagerland, Morten W; Jensen, Torstein; Hallén, Jonas; Agewall, Stefan; Atar, Dan

    2014-05-01

    Cardiac troponins (cTn) are to date the most sensitive and specific biochemical markers of myocardial injury. Abnormal breathing patterns in patients with obstructive sleep apnea (OSA) may cause myocardial cell stress detectable by novel cTn assays. The objectives of this study were to investigate whether a new single-molecule cTnI (S-cTnI) assay and a commercially available high-sensitivity cTnT (hs-cTnT) assay would detect myocyte injury in individuals evaluated for possible OSA, and to explore their relation to variables of disordered breathing during sleep. Consecutive individuals referred to Lovisenberg Diakonale Hospital's sleep laboratory between 1 October 2009 and 1 March 2010 were included. We measured cTn in specimens collected the morning after sleep and studied these in relation to variables recorded during polygraphy or polysomnography. All 222 (100 %) individuals had measurable cTn levels using either assay. Stratified into categories according to the apnea-hypopnea index (AHI), patients with OSA (AHI ≥5) had a different distribution of S-cTnI (P = 0.036) and hs-cTnT (P = 0.002) compared to those without (AHI <5). The median (quartiles 1-3) were 3.0 (1.9-6.0) versus 2.3 (1.6-3.8) ng/l for S-cTnI, and 7.0 (5.5-8.7) versus 6.2 (4.9-7.2) ng/l for hs-cTnT. However, in multiple median regression analyses adjusted for conventional predictors, neither S-cTnI (P = 0.57) nor hs-cTnT (P = 0.80) were significantly associated with AHI. This study reveals no association independent of conventional predictors between OSA and myocardial cell injury measured by S-cTnI and hs-cTnT assays. Our findings support a search for novel biomarkers for prognostication of OSA.

  18. Small-angle x-ray scattering investigation of the solution structure of troponin C

    International Nuclear Information System (INIS)

    Hubbard, S.R.; Hodgson, K.O.; Doniach, S.

    1988-01-01

    X-ray crystallographic studies of troponin C have revealed a novel protein structure consisting of two globular domains, each containing two Ca 2+ -binding sites, connected via a nine-turn alpha-helix, three turns of which are fully exposed to solvent. Since the crystals were grown at pH approximately 5, it is of interest to determine whether this structure is applicable to the protein in solution under physiological conditions. We have used small-angle x-ray scattering to examine the solution structure of troponin C at pH 6.8 and the effect of Ca 2+ on the structure. The scattering data are consistent with an elongated structure in solution with a radius of gyration of approximately 23.0 A, which is quite comparable to that computed for the crystal structure. The experimental scattering profile and the scattering profile computed from the crystal structure coordinates do, however, exhibit differences at the 40-A level. A weak Ca 2+ -facilitated dimerization of troponin C was observed. The data rule out large Ca 2+ -induced structural changes, indicating rather that the molecule with Ca 2+ bound is only slightly more compact than the Ca 2+ -free molecule

  19. Factors independently associated with cardiac troponin I levels in young and healthy adults from the general population.

    Science.gov (United States)

    Bossard, Matthias; Thériault, Sébastien; Aeschbacher, Stefanie; Schoen, Tobias; Kunz, Seraina; von Rotz, Mirco; Estis, Joel; Todd, John; Risch, Martin; Mueller, Christian; Risch, Lorenz; Paré, Guillaume; Conen, David

    2017-02-01

    Determinants of cardiomyocyte injury as quantified by high-sensitivity cardiac troponin I (cTnI) in young and healthy individuals, and sex-specific 99th percentiles are largely unknown. Our study included 2077 adults from the general population aged 25-41 years without cardiovascular disease. cTnI was measured using a high-sensitivity assay. We performed stepwise backward linear regression analyses to identify variables independently associated with hs-cTnI levels, and calculated narrow-sense heritability from 1638-genotyped participants. Median age was 37 years. cTnI was quantifiable in all but 11 participants (99.5 %). Median (interquartile range) cTnI was significantly higher in men than in women [0.99 (0.71; 1.65) versus 0.47 (0.33; 0.71) ng/L, p age, systolic blood pressure, heart rate, left ventricular mass, N-terminal pro B-type natriuretic peptide, and creatine kinase (all p age, and systolic blood pressure belong to the strongest determinants of hs-cTnI in healthy adults. The 99th percentile was three times higher in men compared to women. Hence, sex-specific cut-off values may be preferable when applying hs-cTnI for screening purposes. Our results may also improve the interpretation of cTn levels in daily clinical practice.

  20. The relationship of plasma creatinine (as eGFR) and high-sensitivity cardiac troponin and NT-proBNP concentrations in a hospital and community outpatient population.

    Science.gov (United States)

    Potter, Julia M; Simpson, Aaron J; Kerrigan, Jennifer; Southcott, Emma; Salib, Marie M; Koerbin, Gus; Hickman, Peter E

    2017-10-01

    While persons with overt renal failure have a well-described rise in troponin and NT-proBNP, it is less well described what the relationship is between cardiac markers and persons with impaired renal function, not requiring dialysis. We have collected ALL samples referred to our pathology practice over a 24h period and measured hs-cTnI, hs-cTnT, NT-proBNP, calculated the eGFR, and related our measurements to clinical outcomes. For both men and women, for all of hs-cTnI, hs-cTnT and NT-proBNP, there was a graded response, as renal function worsened, the concentration of the cardiac marker increased. There is a graded inverse relationship between eGFR and the concentrations of hs-cTnI, hs-cTnT and NT-proBNP. For women only there appeared to be an increase in mortality at lowest eGFR. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. Cardiac troponin I degradation in serum of patients with hypertrophic obstructive cardiomyopathy undergoing percutaneous septal ablation

    DEFF Research Database (Denmark)

    Madsen, Lene H; Lund, Terje; Grieg, Zanina

    2009-01-01

    prior to initiation of PTSMA and up to 50 h following the procedure. Western blot analysis was performed with subsequent analysis of relative intensities of the bands as compared to the degradation of cTnI in STEMI patients from the ASSENT-2 troponin substudy. RESULTS: We demonstrate intact cTnI and 9...... degradation products [molecular weight (MW) 12.0-23.5 kDa]. The bands were comparable in MW to degradation fragments in STEMI. Their early rise in intensity, occurring within few minutes after the alcohol injection, emphasizes how susceptible troponin bands are to chemical/ischemic insults. Moreover, two...... additional bands were visible in the PTSMA population. CONCLUSION: This work describes the degradation products of troponin I in HOCM patients undergoing PTSMA. The detected bands appear fast and are similar to degradations following STEMI. This model contributes to our knowledge of the degradation patterns...

  2. Impact of statin use on exercise-induced cardiac troponin elevations.

    NARCIS (Netherlands)

    Eijsvogels, T.M.H.; Januzzi, J.L., Jr.; Taylor, B.A.; Isaacs, S.K.; D'Hemecourt, P.; Zaleski, A.; Dyer, S.; Troyanos, C.; Weiner, R.B.; Thompson, P.D.; Baggish, A.L.

    2014-01-01

    Marathon running commonly causes a transient elevation of creatine kinase and cardiac troponin I (cTnI). The use of statins before marathon running exacerbates the release of creatine kinase from skeletal muscle, but the effect of statin use on exercise-induced cTnI release is unknown. We therefore

  3. Fluorescent Protein-Based Ca2+ Sensor Reveals Global, Divalent Cation-Dependent Conformational Changes in Cardiac Troponin C.

    Directory of Open Access Journals (Sweden)

    Myriam A Badr

    Full Text Available Cardiac troponin C (cTnC is a key effector in cardiac muscle excitation-contraction coupling as the Ca2+ sensing subunit responsible for controlling contraction. In this study, we generated several FRET sensors for divalent cations based on cTnC flanked by a donor fluorescent protein (CFP and an acceptor fluorescent protein (YFP. The sensors report Ca2+ and Mg2+ binding, and relay global structural information about the structural relationship between cTnC's N- and C-domains. The sensors were first characterized using end point titrations to decipher the response to Ca2+ binding in the presence or absence of Mg2+. The sensor that exhibited the largest responses in end point titrations, CTV-TnC, (Cerulean, TnC, and Venus was characterized more extensively. Most of the divalent cation-dependent FRET signal originates from the high affinity C-terminal EF hands. CTV-TnC reconstitutes into skinned fiber preparations indicating proper assembly of troponin complex, with only ~0.2 pCa unit rightward shift of Ca2+-sensitive force development compared to WT-cTnC. Affinity of CTV-TnC for divalent cations is in agreement with known values for WT-cTnC. Analytical ultracentrifugation indicates that CTV-TnC undergoes compaction as divalent cations bind. C-terminal sites induce ion-specific (Ca2+ versus Mg2+ conformational changes in cTnC. Our data also provide support for the presence of additional, non-EF-hand sites on cTnC for Mg2+ binding. In conclusion, we successfully generated a novel FRET-Ca2+ sensor based on full length cTnC with a variety of cellular applications. Our sensor reveals global structural information about cTnC upon divalent cation binding.

  4. Troponin rise in hospitalized patients with nonacute coronary syndrome: retrospective assessment of outcomes and predictors.

    Science.gov (United States)

    Dhesi, Sumandeep; Shanks, Miriam; Tymchak, Wayne J

    2015-03-01

    Cardiac troponin is elevated in several clinical settings apart from thrombotic acute coronary syndrome (ACS) and is associated with increased adverse events. It is not clear whether troponin elevation in type II myocardial infarction (MI) is associated with increased cardiovascular events. Our objectives were to identify the cause of mortality in type II MI and to attempt to establish the threshold range of cardiac troponin-I (cTnI) elevation as well as clinical factors associated with adverse outcomes in type II MI. This retrospective cohort study included 245 patients presenting with a noncardiac primary diagnosis associated with cTnI elevation at a single centre from January 2003 to December 2011. Primary outcome was a composite of cardiovascular and noncardiovascular mortality. Secondary outcomes included subsequent stroke, ACS, and heart failure (HF). At 1 year, ACS occurred in 13 patients (5.3%), stroke was seen in 10 (4.1%) patients, and HF occurred in 19 (7.8%) patients. Overall 1-year mortality included 102 events (41.6%), with 10 cardiovascular deaths (9.8%), 65 noncardiovascular deaths (63.7%), and 27 (26.5%) deaths from unknown causes. In multivariable analysis, factors independently associated with increased overall 1-year mortality included cTnI elevation ≥ 4.63 μg/L (odds ratio [OR], 3.37; 95% confidence interval [CI], 1.55-7.34; P = 0.002), age ≥ 70 years (OR, 2.44; 95% CI, 1.40-4.29; P = 0.002), and estimated glomerular filtration rate high after type II MI, the majority of mortality is caused by noncardiovascular events. Copyright © 2015 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  5. Single histidine button in cardiac troponin I sustains heart performance in response to severe hypercapnic respiratory acidosis in vivo.

    Science.gov (United States)

    Palpant, Nathan J; D'Alecy, Louis G; Metzger, Joseph M

    2009-05-01

    Intracellular acidosis is a profound negative regulator of myocardial performance. We hypothesized that titrating myofilament calcium sensitivity by a single histidine substituted cardiac troponin I (A164H) would protect the whole animal physiological response to acidosis in vivo. To experimentally induce severe hypercapnic acidosis, mice were exposed to a 40% CO(2) challenge. By echocardiography, it was found that systolic function and ventricular geometry were maintained in cTnI A164H transgenic (Tg) mice. By contrast, non-Tg (Ntg) littermates experienced rapid and marked cardiac decompensation during this same challenge. For detailed hemodymanic assessment, Millar pressure-conductance catheterization was performed while animals were treated with a beta-blocker, esmolol, during a severe hypercapnic acidosis challenge. Survival and load-independent measures of contractility were significantly greater in Tg vs. Ntg mice. This assay showed that Ntg mice had 100% mortality within 5 min of acidosis. By contrast, systolic and diastolic function were protected in Tg mice during acidosis, and they had 100% survival. This study shows that, independent of any beta-adrenergic compensation, myofilament-based molecular manipulation of inotropy by histidine-modified troponin I maintains cardiac inotropic and lusitropic performance and markedly improves survival during severe acidosis in vivo.

  6. Selection of specific inhibitor peptides in enzyme-linked immunosorbent assay (ELISA) of cardiac troponin I using immuno-dominant epitopes as competitor.

    Science.gov (United States)

    Rezaee, Majid Asiabanha; Rasaee, Mohammad Javad; Mohammadnejad, Javad

    2017-01-01

    Human cardiac troponin I (cTni) is the gold marker for early diagnosis of myocardial infarction. In this regard, four immune-dominant epitopes of cTni were predicted and their 3D structures were determined. Thereafter, the competitive performance of the peptides was monitored with the developed polyclonal antibody-based indirect competitive ELISA; a half-maximal inhibitory concentration (IC50) of 0.49 (µg/mL) and detection limit of 0.037 (µg/mL) were achieved for recombinant cTni. The competitive ELISA determined sensitivity levels of 0.306, 0.141, 0.960, and 0.155 (µg/mL), respectively, for each peptide as competitor. We indicated that two of the selected epitopes have significant sensitivity scales and inhibition ability.

  7. Incidence of major vascular events after cardiac surgery: impact of preoperative monitoring with troponin and electrocardiogram

    International Nuclear Information System (INIS)

    Sandra M Quiroga; Juan C Villar; Luz X, Martinez

    2009-01-01

    Recent demographic changes have led to an increased risk of major vascular events among patients undergoing non-cardiac surgery. Troponin and electrocardiogram monitoring would further identify these major vascular events. Methods: we prospectively collected data on eligible patients (non-selected individuals aged 45 or older undergoing non-cardiac surgery under general or regional anesthesia in two hospitals in Bucaramanga, with expected length of stay longer than 24 hours) during a time-interrupted series,before and after postoperative diagnostic monitoring (blinded assessment of troponin T and electrocardiograms ignoring clinical data). For the period before the intervention (usual clinical care),two independent reviewers extracted clinical information from clinical histories (of all eligible patients from 3 randomly-selected months of 2005). For the period after diagnostic monitoring, we followed 100 consecutive eligible patients. Primary outcome was a composite of major vascular events within hospital, including myocardial infarction (defined as any troponin elevation associated with electrocardiographic changes suggesting ischemia, regardless of symptoms). Results: we included 534 clinical charts and 100 prospective surgical patients (mean age 62.2, SD 12.9 years; 56% women). The more frequent surgical procedures were orthopedics (26.8%) followed by abdominal (20.2%).The incidence of major vascular events recorded in clinical charts was 2.8%, compared with 7% among monitored patients (p=0,071). All four myocardial infarctions identified among the later group were silent. Conclusion: postoperative monitoring with troponin and electrocardiography identified a higher proportion of major vascular events, mainly silent myocardial infarctions.

  8. The impact of intermittent exercise in a hypoxic environment on redox status and cardiac troponin release in the serum of well-trained marathon runners.

    Science.gov (United States)

    Li, Feifei; Nie, Jinlei; Lu, Yifan; Tong, Tom Kwok Keung; Yi, Longyan; Yan, Huiping; Fu, Frank Hoo Kin; Ma, Shengxia

    2016-10-01

    To investigate the effects of hypoxic training on redox status and cardiac troponin (cTn) release after intermittent exercise. Nine well-trained male marathon runners (age, 21.7 ± 2.3 year; body mass, 64.7 ± 4.8 kg; height, 177.9 ± 3.8 cm; and VO2max, 64.3 ± 6.7 ml kg(-1) min(-1)) completed intermittent exercise under normoxic [trial N; fraction of inspiration oxygen (FIO2), 21.0 %] and hypoxic (trial H; FIO2, 14.4 %) conditions in random order. Each bout of intermittent exercise included hard run (16.2 ± 0.8 km h(-1)) at 90 % VO2max for 2 min followed by easy run (9.0 ± 0.4 km h(-1)) at 50 % VO2max for 2 min and 23 bouts in 92 min totally. Malondialdehyde, reduced glutathione (GSH), superoxide dismutase, an estimate of total antioxidant capacity (T-AOC), high-sensitivity cardiac troponin T (hs-cTnT), and cardiac troponin I (cTnI) were measured before, immediately after (0 h), and 2, 4, and 24 h after the completion of trials N and H. GSH was increased immediately after trial N. T-AOC was lower 4 h after trial H than trial N. Hs-cTnT was elevated from 0 to 4 h and returned to baseline 24 h after both trials. CTnI was increased after trial H; peaked at 2-4 h and returned to below the detection by 24 h. The overall redox status was balanced under normoxic conditions, and exercise-induced cTn release did not deviate. However, the protective effects of antioxidant were weaker in the hypoxic state than normoxic, and the stress on the myocardium induced by intermittent exercise was transiently aggravated.

  9. Electrocardiographic Findings and Serum Troponin I in Carbon Monoxide Poisoned Patients

    Directory of Open Access Journals (Sweden)

    Scott Reza Jafarian Kerman

    2012-03-01

    Full Text Available Carbon monoxide (CO poisoning, though with different sources, is one of the most deadly emergencies in all countries. CO can threaten men's life by several paths especially cardiac complications, which can mimic other cardiac problems such as myocardial infarction. The objective of this study was to determine ECG findings and serum troponin I levels in CO poisoned patients. In this analytical cross-sectional study, 63 CO poisoning patients were consecutively included from hospital's emergency departments. CO content was measured by a CO-oximeter and an electrocardiography was taken first thing on admission. Arterial blood gas (ABG, troponin I and other data was collected afterwards. Data were divided by age groups (adults and children and gender. CO content was significantly higher only in subjects with normal T wave compared to patients with inverted T wave in their initial ECG (P=0.016. No other significant difference was noticed. None of the ABG findings correlated significantly with CO content. Also no significant correlation was found with CO content after stratification by gender and age groups, but pH in children (r=-0.484, P=0.026. CO content was significantly higher in adults (P=0.023, but other ABG data were not significantly different. Only 3 patients had elevated troponin I. Receiver operating characteristic (ROC analysis showed no significant cutoff points in CO content for ECG changes. No significant specific change in electrocardiograms (ECG could contribute carboxyhemoglobin content in carbon monoxide poisoned patients. In addition, no specific difference was found between adults and pediatric subjects' ECGs. All other findings seemed to be accidental.

  10. A randomized cross-over study of the acute effects of running 5 km on glucose, insulin, metabolic rate, cortisol and Troponin T

    OpenAIRE

    Keselman, Boris; Vergara, Marta; Nyberg, Sofia; Nystrom, Fredrik H.

    2017-01-01

    Background We aimed to study the impact by running 5 km, at maximal speed, on the normal variations of metabolic variables related to glucose, insulin, insulin sensitivity, cortisol, glucagon, Troponin T and metabolic rate. Material and methods Five women and 12 men 25.7 +/- 5.2 years of age with a body-mass-index of 22.5 +/- 2.3 kg/m(2) where recruited to run 5 km at individual maximal speed in the morning, and to a corresponding day of rest, followed by standardized breakfast and lunch meal...

  11. Prediction of troponin-T degradation using color image texture features in 10d aged beef longissimus steaks.

    Science.gov (United States)

    Sun, X; Chen, K J; Berg, E P; Newman, D J; Schwartz, C A; Keller, W L; Maddock Carlin, K R

    2014-02-01

    The objective was to use digital color image texture features to predict troponin-T degradation in beef. Image texture features, including 88 gray level co-occurrence texture features, 81 two-dimension fast Fourier transformation texture features, and 48 Gabor wavelet filter texture features, were extracted from color images of beef strip steaks (longissimus dorsi, n = 102) aged for 10d obtained using a digital camera and additional lighting. Steaks were designated degraded or not-degraded based on troponin-T degradation determined on d 3 and d 10 postmortem by immunoblotting. Statistical analysis (STEPWISE regression model) and artificial neural network (support vector machine model, SVM) methods were designed to classify protein degradation. The d 3 and d 10 STEPWISE models were 94% and 86% accurate, respectively, while the d 3 and d 10 SVM models were 63% and 71%, respectively, in predicting protein degradation in aged meat. STEPWISE and SVM models based on image texture features show potential to predict troponin-T degradation in meat. © 2013.

  12. Blood troponin levels in acute cardiac events depends on space weather activity components (a correlative study).

    Science.gov (United States)

    Stoupel, Eliiyahu; Radishauskas, Richardas; Bernotiene, Gailute; Tamoshiunas, Abdonas; Virvichiute, Daiva

    2018-02-05

    Many biological processes are influenced by space weather activity components such as solar activity (SA), geomagnetic activity (GMA) and cosmic ray activity (CRA). Examples are total mortality, acute myocardial infarction (AMI), stroke (cerebrovascular accident), sudden cardiac death, some congenital maladies (congenital heart disease and Down syndrome), many events in neonatology, ophtalmology, blood pressure regulation, blood coagulation, inflammation, etc. The aim of this study was to check if the level of blood troponins (Tns) - markers of myocardial damage and recognized components of modern description of AMI - is connected with the mentioned space weather parameters. Patients admitted to a 3000-bed tertiary university hospital in Kaunas, Lithuania, with suspected AMI were the object of the study. Data for the time between 2008 and 2013 - 72 consecutive months - were studied. Of the patients, 1896 (1398 male, 498 female) had elevated troponin I (Tn I) or troponin T (Tn T, sensitive Tn) levels. Normal values were 0.00-0.03 ng/mL for Tn I and 0.00-14.00 ng/mL for Tn T. Monthly means and standard deviation of Tn I and Tn T were compared with monthly markers of SA, GMA and CRA. Pearson correlation coefficients and their probabilities were established (in addition to the consecutive graphs of both comparing physical and biological data). The cosmophysical data came from space service institutions in the United States, Russia and Finland. AMI was diagnosed in 1188 patients (62.66%), and intermediate coronary syndrome in 698 patients (36.81%). There were significant links of the Tn blood levels with four SA indices and CRA (neutron activity in imp/min); there was no significant correlation with GMA indices Ap and Cp (p=0.27 and p=0.235). Tn T levels significantly correlated with the GMA indices and not with the SA and CRA levels (Ap: r=0.77, p=0.0021; Cp: r=0.729, p=0.0047). First, the monthly level of blood Tn I in ACS is significantly correlated with the indices

  13. Serum levels of troponin I in obese adults attending University of ...

    African Journals Online (AJOL)

    Background: Obesity according to World Health Organization (WHO) is a condition in which excess body fat has accumulated to the extent that it may have an adverse effect on health leading to reduced life expectancy and increased health problem. Aim: To determine the serum concentrations of troponin I in obese adults ...

  14. Association of cardiac troponin I with disease severity and outcomes in patients with pulmonary hypertension.

    Science.gov (United States)

    Vélez-Martínez, Mariella; Ayers, Colby; Mishkin, Joseph D; Bartolome, Sonja B; García, Christine K; Torres, Fernando; Drazner, Mark H; de Lemos, James A; Turer, Aslan T; Chin, Kelly M

    2013-06-15

    Previous studies have identified cardiac troponin I (cTnI) as an important marker in pulmonary hypertension (PH) prognosis. However, traditional assays are limited by poor sensitivity, even among patients at high risk. cTnI was measured in 255 PH patients using a new highly sensitive (hs) assay. Other measures included demographics, creatinine, 6-minute walk distance, hemodynamics, cardiac magnetic resonance imaging, and B-type natriuretic peptide level. The association between cTnI and survival was assessed using Kaplan-Meier analysis and Cox regression. cTnI was detectable with the hs assay in 95% of the patients with a median level of 6.9 pg/ml (IQR 2.7-12.6 pg/ml). Higher cTnI levels associated with higher levels of B-type natriuretic peptide, shorter 6-minute walk distance, and more severe hemodynamic and cardiac magnetic resonance imaging abnormalities. During a median follow-up of 3.5 years, 60 individuals died. Unadjusted event rates increased across higher cTnI quartiles (3, 5, 13, 17 events/100 person-years, respectively, p trend = 0.002). cTnI in the fourth (vs first) quartile remained associated with death in a final stepwise multivariable model that included clinical variables and hemodynamics (adjusted hazard ratio 5.3, 95% confidence interval 1.8-15.6). In conclusion, cTnI levels, detectable with a novel hs assay, identify patients with PH who have more severe hemodynamic and cardiac structural abnormalities and provide novel and independent prognostic information. This hs assay has the potential to detect more at-risk patients and improve current risk-stratification algorithms. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Identification and expression of troponin T, a new marker on the surface of cultured tumor endothelial cells by aptamer ligand

    International Nuclear Information System (INIS)

    Ara, Mst Naznin; Hyodo, Mamoru; Ohga, Noritaka; Akiyama, Kosuke; Hida, Kyoko; Hida, Yasuhiro; Shinohara, Nobuo; Harashima, Hideyoshi

    2014-01-01

    The identification of a specific biomarker involves the development of new clinical diagnostic tools, and an in-depth understanding of the disease at the molecular level. When new blood vessels form in tumor cells, endothelial cell production is induced, a process that plays a key role in disease progression and metastasis to distinct organs for solid tumor types. The present study reports on the identification of a new biomarker on primary cultured mouse tumor endothelial cells (mTECs) using our recently developed high-affinity DNA aptamer AraHH001 (K d = 43 nmol/L) assisted proteomics approach. We applied a strategy involving aptamer-facilitated biomarker discovery. Biotin-tagged AraHH001 was incubated with lysates of mTECs and the aptamer-proteins were then conjugated with streptavidin magnetic beads. Finally, the bound proteins were separated by sodiumdodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) with silver staining. We identified troponin T via matrix assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry, the molecular target of aptamer AraHH001, and its presence was confirmed by measuring mRNA, protein levels, western blot, immunostaining, a gel shift assay of AraHH001 with troponin T. We first report here on the discovery of troponin T on mTECs, a promising and interesting diagnostic tool in the development of antiangiogenic therapy techniques the involves the targeting of the tumor vasculature

  16. Troponin T3 expression in skeletal and smooth muscle is required for growth and postnatal survival: characterization of Tnnt3(tm2a(KOMP)Wtsi) mice.

    Science.gov (United States)

    Ju, Yawen; Li, Jie; Xie, Chao; Ritchlin, Christopher T; Xing, Lianping; Hilton, Matthew J; Schwarz, Edward M

    2013-09-01

    The troponin complex, which consists of three regulatory proteins (troponin C, troponin I, and troponin T), is known to regulate muscle contraction in skeletal and cardiac muscle, but its role in smooth muscle remains controversial. Troponin T3 (TnnT3) is a fast skeletal muscle troponin believed to be expressed only in skeletal muscle cells. To determine the in vivo function and tissue-specific expression of Tnnt3, we obtained the heterozygous Tnnt3+/flox/lacZ mice from Knockout Mouse Project (KOMP) Repository. Tnnt3(lacZ/+) mice are smaller than their WT littermates throughout development but do not display any gross phenotypes. Tnnt3(lacZ/lacZ) embryos are smaller than heterozygotes and die shortly after birth. Histology revealed hemorrhagic tissue in Tnnt3(lacZ/lacZ) liver and kidney, which was not present in Tnnt3(lacZ/+) or WT, but no other gross tissue abnormalities. X-gal staining for Tnnt3 promoter-driven lacZ transgene expression revealed positive staining in skeletal muscle and diaphragm and smooth muscle cells located in the aorta, bladder, and bronchus. Collectively, these findings suggest that troponins are expressed in smooth muscle and are required for normal growth and breathing for postnatal survival. Moreover, future studies with this mouse model can explore TnnT3 function in adult muscle function using the conditional-inducible gene deletion approach Copyright © 2013 Wiley Periodicals, Inc.

  17. Baseline cardiac troponin t levels are elevated in subjects with untreated diabetes mellitus

    DEFF Research Database (Denmark)

    Pareek, M; Nielsen, M L; Leósdóttir, M

    2015-01-01

    Objective: Cardiac troponins are biomarkers of myocardial injury and serve both diagnostic and prognostic purposes. Even mild elevations represent subclinical myocardial damage in the general population. The objective of this study was to investigate the relationship between glucometabolic status...

  18. [Diagnostics of acute myocardial infarction in elderly patients].

    Science.gov (United States)

    Bahrmann, P; Heppner, H J; Bahrmann, A; Christ, M; Bertsch, T; Sieber, C C

    2011-06-01

    The early diagnosis of an acute myocardial infarction (MI) is improved by the introduction of novel high-sensitivity troponin assays. These assays can measure low level myocardial injury not detectable by standard troponin assays. Especially in older patients who appear to have a higher basal troponin level, the results must always be judged in the context of the medical history, physical examination, electrocardiogram (ECG) and any further findings. Even small increases in high-sensitivity troponin indicate increased risk for death or MI during follow-up. In the case of MI an invasive strategy results in better survival rates compared with conservative therapy but at the expense of an increased risk of bleeding in elderly patients. This article provides an overview on the diagnosis of MI in elderly patients.

  19. Rapid detection of cardiac troponin I using antibody-immobilized gate-pulsed AlGaN/GaN high electron mobility transistor structures

    Science.gov (United States)

    Yang, Jiancheng; Carey, Patrick; Ren, Fan; Wang, Yu-Lin; Good, Michael L.; Jang, Soohwan; Mastro, Michael A.; Pearton, S. J.

    2017-11-01

    We report a comparison of two different approaches to detecting cardiac troponin I (cTnI) using antibody-functionalized AlGaN/GaN High Electron Mobility Transistors (HEMTs). If the solution containing the biomarker has high ionic strength, there can be difficulty in detection due to charge-screening effects. To overcome this, in the first approach, we used a recently developed method involving pulsed biases applied between a separate functionalized electrode and the gate of the HEMT. The resulting electrical double layer produces charge changes which are correlated with the concentration of the cTnI biomarker. The second approach fabricates the sensing area on a glass slide, and the pulsed gate signal is externally connected to the nitride HEMT. This produces a larger integrated change in charge and can be used over a broader range of concentrations without suffering from charge-screening effects. Both approaches can detect cTnI at levels down to 0.01 ng/ml. The glass slide approach is attractive for inexpensive cartridge-type sensors.

  20. Troponin is a Potential Marker of Subclinical Myocardial Injury in Patient Undergoing Chemotherapy

    Czech Academy of Sciences Publication Activity Database

    Umlauf, J.; Pecen, Ladislav; Šimíčková, M.; Nekulová, M.; Vondráček, V.; Valík, D.

    2002-01-01

    Roč. 17, č. 3 (2002), s. 131 ISSN 0886-3849. [International Conference on Human Tumor Markers /19./. 25.08.2002-29.08.2002, Velje] Institutional research plan: AV0Z1030915 Keywords : markers of myocardial injury * troponin Subject RIV: BA - General Mathematics

  1. The structure of the muscle protein complex 4Ca2+. Tronponin C*troponin: A Monte Carlo modeling analysis of small-angle X-ray and neutron scattering data

    International Nuclear Information System (INIS)

    Olah, G.A.; Trewhella, J.

    1995-01-01

    Analysis of scattering data based on a Monte Carlo integration method was used to obtain a low resolution model of the 4Ca2+.troponin c.troponin I complex. This modeling method allows rapid testing of plausible structures where the best fit model can be ascertained by a comparison between model structure scattering profiles and measured scattering data. In the best fit model, troponin I appears as a spiral structure that wraps about 4CA2+.trophonin C which adopts an extended dumbell conformation similar to that observed in the crystal structures of troponin C. The Monte Carlo modeling method can be applied to other biological systems in which detailed structural information is lacking

  2. A High-Performance Fluorescence Immunoassay Based on the Relaxation of Quenching, Exemplified by Detection of Cardiac Troponin I

    Directory of Open Access Journals (Sweden)

    Seung-Wan Kim

    2016-05-01

    Full Text Available The intramolecular fluorescence self-quenching phenomenon is a major drawback in developing high-performance fluorometric biosensors which use common fluorophores as signal generators. We propose two strategies involving liberation of the fluorescent molecules by means of enzymatic fragmentation of protein or dehybridization of double-stranded DNA. In the former, bovine serum albumin (BSA was coupled with the fluorescent BODIPY dye (Red BSA, and then immobilized on a solid surface. When the insolubilized Red BSA was treated with proteinase K (10 units/mL for 30 min, the fluorescent signal was significantly increased (3.5-fold compared to the untreated control. In the second case, fluorophore-tagged DNA probes were linked to gold nanoparticles by hybridization with capture DNA strands densely immobilized on the surface. The quenched fluorescence signal was recovered (3.7-fold by thermal dehybridization, which was induced with light of a specific wavelength (e.g., 530 nm for less than 1 min. We next applied the Red BSA self-quenching relaxation technique employing enzymatic fragmentation to a high-performance immunoassay of cardiac troponin I (cTnI in a microtiter plate format. The detection limit was 0.19 ng/mL cTnI, and the fluorescent signal was enhanced approximately 4.1-fold compared with the conventional method of direct measurement of the fluorescent signal from a non-fragmented fluorophore-labeled antibody.

  3. Drosophila muscleblind is involved in troponin T alternative splicing and apoptosis.

    Directory of Open Access Journals (Sweden)

    Marta Vicente-Crespo

    2008-02-01

    Full Text Available Muscleblind-like proteins (MBNL have been involved in a developmental switch in the use of defined cassette exons. Such transition fails in the CTG repeat expansion disease myotonic dystrophy due, in part, to sequestration of MBNL proteins by CUG repeat RNA. Four protein isoforms (MblA-D are coded by the unique Drosophila muscleblind gene.We used evolutionary, genetic and cell culture approaches to study muscleblind (mbl function in flies. The evolutionary study showed that the MblC protein isoform was readily conserved from nematods to Drosophila, which suggests that it performs the most ancestral muscleblind functions. Overexpression of MblC in the fly eye precursors led to an externally rough eye morphology. This phenotype was used in a genetic screen to identify five dominant suppressors and 13 dominant enhancers including Drosophila CUG-BP1 homolog aret, exon junction complex components tsunagi and Aly, and pro-apoptotic genes Traf1 and reaper. We further investigated Muscleblind implication in apoptosis and splicing regulation. We found missplicing of troponin T in muscleblind mutant pupae and confirmed Muscleblind ability to regulate mouse fast skeletal muscle Troponin T (TnnT3 minigene splicing in human HEK cells. MblC overexpression in the wing imaginal disc activated apoptosis in a spatially restricted manner. Bioinformatics analysis identified a conserved FKRP motif, weakly resembling a sumoylation target site, in the MblC-specific sequence. Site-directed mutagenesis of the motif revealed no change in activity of mutant MblC on TnnT3 minigene splicing or aberrant binding to CUG repeat RNA, but altered the ability of the protein to form perinuclear aggregates and enhanced cell death-inducing activity of MblC overexpression.Taken together our genetic approach identify cellular processes influenced by Muscleblind function, whereas in vivo and cell culture experiments define Drosophila troponin T as a new Muscleblind target, reveal a

  4. Towards evidence-based emergency medicine: Best BETs from the Manchester Royal Infirmary. BET 2: Is there value in testing troponin levels after ICD discharge?

    Science.gov (United States)

    Targett, Chris; Harris, Tim

    2014-03-01

    A short cut review was carried out to establish whether testing for troponin levels is useful after discharge of an Implanted Cardioverter-Defibrillator (ICD). Many papers were found using the reported searches, none of which directly addressed the problem but some 13 presented the best evidence to answer the clinical question. The author, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of those best papers are tabulated. It is concluded that the number of ICD discharges must be taken into account when evaluating any troponin level rise. Overall a positive troponin assay post ICD discharge is independently associated with an increased mortality.

  5. High prevalence of Arginine to Glutamine Substitution at 98, 141 and 162 positions in Troponin I (TNNI3 associated with hypertrophic cardiomyopathy among Indians

    Directory of Open Access Journals (Sweden)

    Rani Deepa

    2012-08-01

    Full Text Available Abstract Background Troponin I (TNNI3 is the inhibitory subunit of the thin filament regulatory complex Troponin, which confers calcium-sensitivity to striated muscle actomyosin ATPase activity. Mutations (2-7% in this gene had been reported in hypertrophic cardiomyopathy patients (HCM. However, the frequencies of mutations and associated clinical presentation have not been established in cardiomyopathy patients of Indian origin, hence we have undertaken this study. Methods We have sequenced all the exons, including the exon-intron boundaries of TNNI3 gene in 101 hypertrophic cardiomyopathy patients (HCM, along with 160 healthy controls, inhabited in the same geographical region of southern India. Results Our study revealed a total of 16 mutations. Interestingly, we have observed Arginine to Glutamine (R to Q mutation at 3 positions 98, 141 and 162, exclusively in HCM patients with family history of sudden cardiac death. The novel R98Q was observed in a severe hypertrophic obstructive cardiomyopathy patient (HOCM. The R141Q mutation was observed in two familial cases of severe asymmetric septal hypertrophy (ASH++. The R162Q mutation was observed in a ASH++ patient with mean septal thickness of 29 mm, and have also consists of allelic heterogeneity by means of having one more synonymous (E179E mutation at g.4797: G → A: in the same exon 7, which replaces a very frequent codon (GAG: 85% with a rare codon (GAA: 14%. Screening for R162Q mutation in all the available family members revealed its presence in 9 individuals, including 7 with allelic heterogeneity (R162Q and E179E of which 4 were severely affected. We also found 2 novel SNPs, (g.2653; G → A and g.4003 C → T exclusively in HCM, and in silico analysis of these SNPs have predicted to cause defect in recognition/binding sites for proteins responsible for proper splicing. Conclusion Our study has provided valuable information regarding the prevalence of TNNI3 mutations in

  6. St. Dominic Savio Nursing Home, Cahilly, Liscannor, Clare.

    LENUS (Irish Health Repository)

    Lee, Graham R

    2016-04-01

    High sensitivity cardiac troponin T and I (hs-cTnT and hs-cTnI) assays show analytical, diagnostic and prognostic improvement over contemporary sensitive cTn assays. However, given the importance of troponin in the diagnosis of myocardial infarction, implementing this test requires rigorous analytical and clinical verification across the total testing pathway. This was the aim of this study.

  7. Analytical evaluation of a new point of care system for measuring cardiac Troponin I

    NARCIS (Netherlands)

    Kemper, D.W.; Semjonow, V.; de Theije, F.; Keizer, D.; van Lippen, L.; Mair, J.; Wille, B.; Christ, M.; Geijer, F.; Hausfater, P.; Pariente, D.; Scharnhorst, V.; Curvers, J.; Nieuwenhuis, J.

    2017-01-01

    OBJECTIVES: Point-of-care cardiac troponin testing with adequate analytical performances has the potential to improve chest pain patients flow in the emergency department. We present the analytical evaluation of the newly developed Philips Minicare cTnI point-of-care immunoassay. DESIGN & METHODS:

  8. Cardiac biomarkers in neonatology: BNP/NTproBNP, troponin I/T, CK-MB and myoglobin – a systematic review

    Directory of Open Access Journals (Sweden)

    Rita P. Teixeira

    2017-06-01

    Full Text Available Cardiac biomarkers play a central role in myocardial injury and heart failure in adult patients, but their clinical relevance in neonatology has not been clearly stablished. The aim of this systematic review was to evaluate the recent literature on B-type natriuretic peptide (BNP/N-terminal-pro-BNP (NTproBNP, troponin I/T, Creatine Kinase-MB (CK-MB and myoglobin and their relationship with different pathologies of the newborn. A total of 67 articles were included to undergo data extraction, after a first text and abstract analysis and a second full-text analysis, using the PubMed database.Evidence shows that cardiac biomarkers are a useful and fast diagnostic tool with great potential for becoming as important as clinical and echocardiographic findings in pathologies of the heart. BNP/NTproBNP and troponin I/T demonstrated to be the ones with greater value. BNP/NTproBNP is of particular significance in the diagnosis and management of patent ductus arteriosus, as it has a good correlation with diagnosis, treatment and prognosis. Troponin T may be a beneficial additional marker for this disease, correlating with ductal significance and treatment response. Moreover, BNP/NTproBNP can be used, with other clinical and laboratory findings, in the diagnosis and as a guide for treatment in pulmonary hypertension and in the diagnosis and management of cardiac sequela in bronchopulmonary dysplasia. Troponin I/T finds its clinical importance in perinatal asphyxia as a marker of myocardial injury and a reliable indicator of severity and mortality. Further studies with larger cohort populations are needed for stablishing the cutoff values specific for each neonatal pathology allowing its early and proper management.

  9. Nanocomposites of gold nanoparticles and graphene oxide towards an stable label-free electrochemical immunosensor for detection of cardiac marker troponin-I.

    Science.gov (United States)

    Liu, Guozhen; Qi, Meng; Zhang, Yin; Cao, Chaomin; Goldys, Ewa M

    2016-02-25

    A stable label-free amperometric immunosensor is presented based on gold nanoparticles and graphene oxide nanocomposites for detection of cardiac troponin-I in the early diagnosis of myocardial infarction. For designing of the sensing platform, firstly the nanocomposites based on GO and AuNPs were prepared and anchored on electrode surfaces. The formed nanocomposites provided a platform with big surface area for loading anti-cTnI capture antibody, and worked as a bridge for fast electron transfer subsequently increased the sensitivity. Moreover, the linkages between AuNP, GO, and electrodes were based on covalent bonding by aryldiazonium salt coupling chemistry, which favors the stability of the sensing interface. Finally, the anti-cTnI detection antibody was immobilized on GO tailored with ferrocene molecules, functioning as the signal reporter for the detection of cTnI. The modification process was monitored using electrochemistry, SEM, XPS. The herein immunosensor demonstrates a good selectivity and high sensitivity against human-cTnI, and is capable of detecting cTnI at concentrations as low as 0.05 ng mL(-1), which is 100 times lower than that possible by conventional methods. It is potential to design the portable sensing platform based on AuNPs and GO nanocomposites for future point-of-care diagnostics. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Troponin T and NT ProBNP Levels in Gestational, Type 1 and Type 2 Diabetic Mothers and Macrosomic Infants.

    Science.gov (United States)

    Mert, Mustafa Kurthan; Satar, Mehmet; Özbarlas, Nazan; Yaman, Akgün; Özgünen, Fatma Tuncay; Asker, Hüseyin Selim; Çekinmez, Eren Kale; Tetiker, Tamer

    2016-01-01

    This study compares NT proBNP and troponin T levels in umbilical cord arterial blood and postnatal echocardiographic findings for infants of gestational and pregestational diabetic mothers and macrosomic infants. Twenty-seven infants of pregestational diabetic mothers, 61 infants of gestational diabetic mothers and 37 macrosomic infants of nondiabetic mothers were prospectively enrolled in this study along with a control group of 58 healthy infants of mothers without any pregestational or gestational disorders as the control group. All enrollees were born after 34 weeks of gestation. For this study, umbilical cord blood was drawn during delivery to determine NT proBNP and troponin T levels. Echocardiography was performed 24-72 h after the delivery. Umbilical cord troponin T and NT proBNP levels were found to be higher in the diabetic and macrosomic groups than in the control group (all of them p gestational infants of diabetic mothers groups (r = 0.564 and r = 0.560, respectively, p gestational diabetic mothers were divided into two groups according to HbA1c levels in the third trimester as good (6.1 %) metabolic control. In the good and suboptimal metabolic control diabetic groups, NT proBNP levels were also positively correlated with interventricular septum thickness (r = 0.536 and r = 0.576, respectively, p mothers and the control group, the myocardial performance index of macrosomic infants was lower than that of the control group (p = 0.017). Cardiac biomarkers (NT proBNP and troponin T) were elevated in infants of diabetic mothers and macrosomic infants. While there was a positive correlation between NT proBNP levels and cardiac structure in infants of pregestational and gestational diabetic mothers, there was no relationship between NT proBNP levels and cardiac function.

  11. Ca2+-induced PRE-NMR changes in the troponin complex reveal the possessive nature of the cardiac isoform for its regulatory switch.

    Directory of Open Access Journals (Sweden)

    Nicole M Cordina

    Full Text Available The interaction between myosin and actin in cardiac muscle, modulated by the calcium (Ca2+ sensor Troponin complex (Tn, is a complex process which is yet to be fully resolved at the molecular level. Our understanding of how the binding of Ca2+ triggers conformational changes within Tn that are subsequently propagated through the contractile apparatus to initiate muscle activation is hampered by a lack of an atomic structure for the Ca2+-free state of the cardiac isoform. We have used paramagnetic relaxation enhancement (PRE-NMR to obtain a description of the Ca2+-free state of cardiac Tn by describing the movement of key regions of the troponin I (cTnI subunit upon the release of Ca2+ from Troponin C (cTnC. Site-directed spin-labeling was used to position paramagnetic spin labels in cTnI and the changes in the interaction between cTnI and cTnC subunits were then mapped by PRE-NMR. The functionally important regions of cTnI targeted in this study included the cTnC-binding N-region (cTnI57, the inhibitory region (cTnI143, and two sites on the regulatory switch region (cTnI151 and cTnI159. Comparison of 1H-15N-TROSY spectra of Ca2+-bound and free states for the spin labeled cTnC-cTnI binary constructs demonstrated the release and modest movement of the cTnI switch region (∼10 Å away from the hydrophobic N-lobe of troponin C (cTnC upon the removal of Ca2+. Our data supports a model where the non-bound regulatory switch region of cTnI is highly flexible in the absence of Ca2+ but remains in close vicinity to cTnC. We speculate that the close proximity of TnI to TnC in the cardiac complex is favourable for increasing the frequency of collisions between the N-lobe of cTnC and the regulatory switch region, counterbalancing the reduction in collision probability that results from the incomplete opening of the N-lobe of TnC that is unique to the cardiac isoform.

  12. Serum cardiac troponin I in acute stroke is related to serum cortisol and TNF-alpha

    DEFF Research Database (Denmark)

    Christensen, Hanne Krarup; Johannesen, Helle Hjorth; Christensen, Anders Fogh

    2004-01-01

    Serum cardiac troponin I (cTnI) is a specific marker of myocardial injury related to in-patient fatality and cardiac injury in acute stroke. We investigated whether cTnI in acute stroke is related to serum cortisol, acute inflammatory response, and insular damage. We also investigated whether c...

  13. Clinical performance of a new point-of-care cardiac troponin I test.

    Science.gov (United States)

    Christ, Michael; Geier, Felicitas; Blaschke, Sabine; Giannitsis, Evangelos; Khellaf, Mehdi; Mair, Johannes; Pariente, David; Scharnhorst, Volkher; Semjonow, Veronique; Hausfater, Pierre

    2018-04-09

    We evaluated the clinical performance of the Minicare cardiac troponin-I (cTnI), a new point-of-care (POC) cTnI test for the diagnosis of acute myocardial infarction (AMI) in a prospective, multicentre study (ISRCTN77371338). Of 474 patients (≥18 years) admitted to an emergency department (ED) or chest pain unit (CPU) with symptoms suggestive of acute coronary syndrome (ACS; ≤12 h from symptom onset), 465 were eligible. Minicare cTnI was tested immediately, 3 h and 6 h after presentation. AMI diagnoses were adjudicated independently based on current guidelines. The diagnostic performance of the Minicare cTnI test at 3 h was similar for whole blood and in plasma: sensitivity 0.92 vs. 0.90; specificity 0.91 vs. 0.90; positive predictive value (PPV) 0.68 vs. 0.66; negative predictive value (NPV) 0.98 vs. 0.98; positive likelihood ratio (LR+) 10.18 vs. 9.41; negative likelihood ratio (LR-) 0.09 vs. 0.11. The optimal diagnostic performance was obtained at 3 h using cut-offs cTnI >43 ng/L plus cTnI change from admission ≥18.5 ng/L: sensitivity 0.90, specificity 0.96, PPV 0.81, NPV 0.98, and LR+ 21.54. The area under the receiver operating characteristics (ROC) curve for cTnI whole blood baseline value and absolute change after 3 h curve was 0.93. These data support the clinical usefulness of Minicare cTnI within a 0 h/3 h-blood sampling protocol supported by current guidelines for the evaluation of suspected ACS.

  14. Prognostic value of predischarge dobutamine stress echocardiography in chest pain patients with a negative cardiac troponin T

    NARCIS (Netherlands)

    Bholasingh, Radha; Cornel, Jan Hein; Kamp, Otto; van Straalen, Jan P.; Sanders, Gerard T.; Tijssen, Jan G. P.; Umans, Victor A. W. M.; Visser, Cees A.; de Winter, Robbert J.

    2003-01-01

    OBJECTIVES We prospectively studied the prognostic value of predischarge dobutamine stress echocardiography (I)SE) in low-risk chest pain patients with a normal or nondiagnostic electrocardiogram (ECG) and a negative serial troponin T. BACKGROUND Noninvasive stress testing is recommended before

  15. Quantitative troponin and death, cardiogenic shock, cardiac arrest and new heart failure in patients with non-ST-segment elevation acute coronary syndromes (NSTE ACS): insights from the Global Registry of Acute Coronary Events.

    Science.gov (United States)

    Jolly, Sanjit S; Shenkman, Heather; Brieger, David; Fox, Keith A; Yan, Andrew T; Eagle, Kim A; Steg, P Gabriel; Lim, Ki-Dong; Quill, Ann; Goodman, Shaun G

    2011-02-01

    The objective of this study was to determine if the extent of quantitative troponin elevation predicted mortality as well as in-hospital complications of cardiac arrest, new heart failure and cardiogenic shock. 16,318 patients with non-ST-segment elevation acute coronary syndromes (NSTE ACS) from the Global Registry of Acute Coronary Events (GRACE) were included. The maximum 24 h troponin value as a multiple of the local laboratory upper limit of normal was used. The population was divided into five groups based on the degree of troponin elevation, and outcomes were compared. An adjusted analysis was performed using quantitative troponin as a continuous variable with adjustment for known prognostic variables. For each approximate 10-fold increase in the troponin ratio, there was an associated increase in cardiac arrest, sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) (1.0, 2.4, 3.4, 5.9 and 13.4%; p<0.001 for linear trend), cardiogenic shock (0.5, 1.4, 2.0, 4.4 and 12.7%; p<0.001), new heart failure (2.5, 5.1, 7.4, 11.6 and 15.8%; p<0.001) and mortality (0.8, 2.2, 3.0, 5.3 and 14.0%; p<0.001). These findings were replicated using the troponin ratio as a continuous variable and adjusting for covariates (cardiac arrest, sustained VT or VF, OR 1.56, 95% CI 1.39 to 1.74; cardiogenic shock, OR 1.87, 95% CI 1.61 to 2.18; and new heart failure, OR 1.57, 95% CI 1.45 to 1.71). The degree of troponin elevation was predictive of early mortality (HR 1.61, 95% CI 1.44 to 1.81; p<0.001 for days 0-14) and longer term mortality (HR 1.18, 95% CI 1.07 to 1.30, p=0.001 for days 15-180). The extent of troponin elevation is an independent predictor of morbidity and mortality.

  16. Decreasing troponin turnaround time in the emergency department using the central laboratory: A process improvement study.

    Science.gov (United States)

    Boelstler, Arlene M; Rowland, Ralph; Theoret, Jennifer; Takla, Robert B; Szpunar, Susan; Patel, Shraddha P; Lowry, Andrew M; Pena, Margarita E

    2015-03-01

    To implement collaborative process improvement measures to reduce emergency department (ED) troponin turnaround time (TAT) to less than 60min using central laboratory. This was an observational, retrospective data study. A multidisciplinary team from the ED and laboratory identified opportunities and developed a new workflow model. Process changes were implemented in ED patient triage, staffing, lab collection and processing. Data collected included TAT of door-to-order, order-to-collect, collect-to-received, received-to-result, door-to-result, ED length of stay, and hemolysis rate before (January-August, 2011) and after (September 2011-June 2013) process improvement. After process improvement and implementation of the new workflow model, decreased median TAT (in min) was seen in door-to-order (54 [IQR43] vs. 11 [IQR20]), order-to-collect (15 [IQR 23] vs. 10 [IQR12]), collect-to-received (6 [IQR8] vs. 5 [IQR5]), received-to-result (30 [IQR12] vs. 24 [IQR11]), and overall door-to-result (117 [IQR60] vs. 60 [IQR40]). A troponin TAT of <60min was realized beginning in May 2012 (59 [IQR39]). Hemolysis rates decreased (14.63±0.74 vs. 3.36±1.99, p<0.0001), as did ED length of stay (5.87±2.73h vs. 5.15±2.34h, p<0.0001). Conclusion Troponin TAT of <60min using a central laboratory was achieved with collaboration between the ED and the laboratory; additional findings include a decreased ED length of stay. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Unusual towering elevation of troponin I after ST-elevation myocardial infarction and intensive monitoring with echocardiography post-percutaneous coronary intervention: a case report

    Directory of Open Access Journals (Sweden)

    Suryadevara Ramya

    2010-05-01

    Full Text Available Abstract Introduction The elevation of troponin levels directly corresponds to the extent of myocardial injury. Here we present a case of a robust rise in cardiac biomarkers that correspond to extensive damage to the myocardium but did not spell doom for our patient. It is important to note that, to the best of our knowledge, this is the highest level of troponin I ever reported in the literature after a myocardial injury in an acute setting. Case presentation A 53-year-old African American man with an unknown medical history presented to the emergency room of our hospital with chest pain associated with diaphoresis and altered mental status. He required emergency intubation due to acute respiratory failure and circulatory collapse within 10 minutes of his arrival. He was started on heparin and eptifibatide (Integrilin drips but he was taken immediately for cardiac catheterization, which showed a total occlusion of his proximal left anterior descending, diffuse left circumflex disease and severe left ventricular dysfunction with segmental wall motion abnormality. He remained hypotensive throughout the procedure and an intra-aortic balloon pump was inserted for circulatory support. His urinary toxicology examination result was positive for cocaine metabolites. Serial echocardiograms showed an akinetic apex, a severely hypokinetic septum, and severe systolic dysfunction of his left ventricle. Our patient stayed at the Coronary Care Unit for a total of 15 days before he was finally discharged. Conclusion Studies demonstrate that an increase of 1 ng/ml in the cardiac troponin I level is associated with a significant increase in the risk ratio for death. The elevation of troponin I to 515 ng/ml in our patient is an unusual robust presentation which may reflect a composite of myocyte necrosis and reperfusion but without short-term mortality. Nevertheless, prolonged close monitoring is required for better outcome. We also emphasize the need for the

  18. Chimeric recombinant antibody fragments in cardiac troponin I immunoassay.

    Science.gov (United States)

    Hyytiä, Heidi; Heikkilä, Taina; Brockmann, Eeva-Christine; Kekki, Henna; Hedberg, Pirjo; Puolakanaho, Tarja; Lövgren, Timo; Pettersson, Kim

    2015-03-01

    To introduce a novel nanoparticle-based immunoassay for cardiac troponin I (cTnI) utilizing chimeric antibody fragments and to demonstrate that removal of antibody Fc-part and antibody chimerization decrease matrix related interferences. A sandwich-type immunoassay for cTnI based on recombinant chimeric (mouse variable/human constant) antigen binding (cFab) antibodies and intrinsically fluorescent nanoparticles was developed. To test whether using chimeric antibody fragments helps to avoid matrix related interferences, samples (n=39) with known amounts of triglycerides, bilirubin, rheumatoid factor (RF) or human anti-mouse antibodies (HAMAs) were measured with the novel assay, along with a previously published nanoparticle-based research assay with the same antibody epitopes. The limit of detection (LoD) was 3.30ng/L. Within-laboratory precision for 29ng/L and 2819ng/L cTnI were 13.7% and 15.9%, respectively. Regression analysis with Siemens ADVIA Centaur® yielded a slope (95% confidence intervals) of 0.18 (0.17-1.19) and a y-intercept of 1.94 (-1.28-3.91) ng/L. When compared to a previously published nanoparticle-based assay, the novel assay showed substantially reduced interference in the tested interference prone samples, 15.4 vs. 51.3%. A rheumatoid factor containing sample was decreased from 241ng/L to sensitive (LoD=3.3ng/L) immunoassay for the detection of cTnI and decreased matrix related interferences, thus resulting in a lower number of falsely elevated cTnI-values. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Fluorescence Lifetime Readouts of Troponin-C-Based Calcium FRET Sensors: A Quantitative Comparison of CFP and mTFP1 as Donor Fluorophores

    Science.gov (United States)

    Laine, Romain; Stuckey, Daniel W.; Manning, Hugh; Warren, Sean C.; Kennedy, Gordon; Carling, David

    2012-01-01

    We have compared the performance of two Troponin-C-based calcium FRET sensors using fluorescence lifetime read-outs. The first sensor, TN-L15, consists of a Troponin-C fragment inserted between CFP and Citrine while the second sensor, called mTFP-TnC-Cit, was realized by replacing CFP in TN-L15 with monomeric Teal Fluorescent Protein (mTFP1). Using cytosol preparations of transiently transfected mammalian cells, we have measured the fluorescence decay profiles of these sensors at controlled concentrations of calcium using time-correlated single photon counting. These data were fitted to discrete exponential decay models using global analysis to determine the FRET efficiency, fraction of donor molecules undergoing FRET and calcium affinity of these sensors. We have also studied the decay profiles of the donor fluorescent proteins alone and determined the sensitivity of the donor lifetime to temperature and emission wavelength. Live-cell fluorescence lifetime imaging (FLIM) of HEK293T cells expressing each of these sensors was also undertaken. We confirmed that donor fluorescence of mTFP-TnC-Cit fits well to a two-component decay model, while the TN-L15 lifetime data was best fitted to a constrained four-component model, which was supported by phasor analysis of the measured lifetime data. If the constrained global fitting is employed, the TN-L15 sensor can provide a larger dynamic range of lifetime readout than the mTFP-TnC-Cit sensor but the CFP donor is significantly more sensitive to changes in temperature and emission wavelength compared to mTFP and, while the mTFP-TnC-Cit solution phase data broadly agreed with measurements in live cells, this was not the case for the TN-L15 sensor. Our titration experiment also indicates that a similar precision in determination of calcium concentration can be achieved with both FRET biosensors when fitting a single exponential donor fluorescence decay model to the fluorescence decay profiles. We therefore suggest that m

  20. Encapsulation-Stabilized, Europium Containing Nanoparticle as a Probe for Time-Resolved luminescence Detection of Cardiac Troponin I

    Directory of Open Access Journals (Sweden)

    Ka Ram Kim

    2017-10-01

    Full Text Available The use of a robust optical signaling probe with a high signal-to-noise ratio is important in the development of immunoassays. Lanthanide chelates are a promising material for this purpose, which provide time-resolved luminescence (TRL due to their large Stokes shift and long luminescence lifetime. From this, they have attracted considerable interest in the in vitro diagnostics field. However, the direct use of lanthanide chelates is limited because their luminescent signal can be easily affected by various quenchers. To overcome this drawback, strategies that rely on the entrapment of lanthanide chelates inside nanoparticles, thereby enabling the protection of the lanthanide chelate from water, have been reported. However, the poor stability of the lanthanide-entrapped nanoparticles results in a significant fluctuation in TRL signal intensity, and this still remains a challenging issue. To address this, we have developed a Lanthanide chelate-Encapsulated Silica Nano Particle (LESNP as a new immunosensing probe. In this approach, the lanthanide chelate is covalently crosslinked within the silane monomer during the silica nanoparticle formation. The resulting LESNP is physically stable and retains TRL properties of the parent lanthanide chelate. Using the probe, a highly sensitive, sandwich-based TRL immunoassay for the cardiac troponin I was conducted, exhibiting a limit of detection of 48 pg/mL. On the basis of the features of the LESNP such as TRL signaling capability, stability, and the ease of biofunctionalization, we expect that the LESNP can be widely applied in the development of TRL-based immunosensing.

  1. Troponin elevations after non-cardiac, non-vascular surgery are predictive of major adverse cardiac events and mortality

    DEFF Research Database (Denmark)

    Ekeloef, S; Alamili, M; Devereaux, P J

    2016-01-01

    -analysis was conducted in January 2016 according to the Meta-analysis Of Observational Studies in Epidemiology guidelines. Both interventional and observational studies measuring troponin within the first 4 days after surgery were eligible. A systematic search was performed in PubMed, EMBASE, Scopus, and the Cochrane...

  2. Cardiac troponin T and fast skeletal muscle denervation in ageing.

    Science.gov (United States)

    Xu, Zherong; Feng, Xin; Dong, Juan; Wang, Zhong-Min; Lee, Jingyun; Furdui, Cristina; Files, Daniel Clark; Beavers, Kristen M; Kritchevsky, Stephen; Milligan, Carolanne; Jin, Jian-Ping; Delbono, Osvaldo; Zhang, Tan

    2017-10-01

    Ageing skeletal muscle undergoes chronic denervation, and the neuromuscular junction (NMJ), the key structure that connects motor neuron nerves with muscle cells, shows increased defects with ageing. Previous studies in various species have shown that with ageing, type II fast-twitch skeletal muscle fibres show more atrophy and NMJ deterioration than type I slow-twitch fibres. However, how this process is regulated is largely unknown. A better understanding of the mechanisms regulating skeletal muscle fibre-type specific denervation at the NMJ could be critical to identifying novel treatments for sarcopenia. Cardiac troponin T (cTnT), the heart muscle-specific isoform of TnT, is a key component of the mechanisms of muscle contraction. It is expressed in skeletal muscle during early development, after acute sciatic nerve denervation, in various neuromuscular diseases and possibly in ageing muscle. Yet the subcellular localization and function of cTnT in skeletal muscle is largely unknown. Studies were carried out on isolated skeletal muscles from mice, vervet monkeys, and humans. Immunoblotting, immunoprecipitation, and mass spectrometry were used to analyse protein expression, real-time reverse transcription polymerase chain reaction was used to measure gene expression, immunofluorescence staining was performed for subcellular distribution assay of proteins, and electromyographic recording was used to analyse neurotransmission at the NMJ. Levels of cTnT expression in skeletal muscle increased with ageing in mice. In addition, cTnT was highly enriched at the NMJ region-but mainly in the fast-twitch, not the slow-twitch, muscle of old mice. We further found that the protein kinase A (PKA) RIα subunit was largely removed from, while PKA RIIα and RIIβ are enriched at, the NMJ-again, preferentially in fast-twitch but not slow-twitch muscle in old mice. Knocking down cTnT in fast skeletal muscle of old mice: (i) increased PKA RIα and reduced PKA RIIα at the NMJ; (ii

  3. Troponin-positive chest pain with unobstructed coronary arteries: incremental diagnostic value of cardiovascular magnetic resonance imaging.

    Science.gov (United States)

    Pathik, Bhupesh; Raman, Betty; Mohd Amin, Nor Hanim; Mahadavan, Devan; Rajendran, Sharmalar; McGavigan, Andrew D; Grover, Suchi; Smith, Emma; Mazhar, Jawad; Bridgman, Cameron; Ganesan, Anand N; Selvanayagam, Joseph B

    2016-10-01

    Troponin-positive chest pain patients with unobstructed coronaries represent a clinical dilemma. Cardiovascular magnetic resonance (CMR) imaging has an increasingly prominent role in the assessment of these patients; however, its utility in addition to expert clinical judgement is unclear. We sought to determine the incremental diagnostic value of CMR and the heterogeneity in diagnoses by experienced cardiologists when presented with blinded clinical and investigative data in this population. A total of 125 consecutive patients presenting to a tertiary centre between 2010 and 2014 with cardiac chest pain, elevated troponin (>29 ng/L), and unobstructed coronaries were enrolled and underwent CMR. A panel of three experienced cardiologists unaware of the CMR diagnosis and blinded to each other's assessment provided a diagnosis based on clinical and investigative findings. A consensus panel diagnosis was defined as two or more cardiologists sharing the same clinical diagnosis. Findings were classified into acute myocarditis, Takotsubo cardiomyopathy, acute myocardial infarction (AMI), or indeterminate. CMR provided a diagnosis in 87% of patients. Consensus panel diagnosis and CMR were concordant in 65/125 (52%) patients. There was an only moderate level of agreement between the three cardiologists (k = 0.47, P < 0.05) and a poor level of agreement between the consensus panel and CMR (k = 0.38, P < 0.05) with the most disagreement seen in patients with AMI diagnosed on CMR. The clinical diagnosis of patients with non-obstructive coronaries and positive troponin remains a challenge. The concordance between CMR and clinical diagnosis is poor. CMR provides a diagnosis in majority of these patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  4. Effect of Xenon Anesthesia Compared to Sevoflurane and Total Intravenous Anesthesia for Coronary Artery Bypass Graft Surgery on Postoperative Cardiac Troponin Release: An International, Multicenter, Phase 3, Single-blinded, Randomized Noninferiority Trial.

    Science.gov (United States)

    Hofland, Jan; Ouattara, Alexandre; Fellahi, Jean-Luc; Gruenewald, Matthias; Hazebroucq, Jean; Ecoffey, Claude; Joseph, Pierre; Heringlake, Matthias; Steib, Annick; Coburn, Mark; Amour, Julien; Rozec, Bertrand; Liefde, Inge de; Meybohm, Patrick; Preckel, Benedikt; Hanouz, Jean-Luc; Tritapepe, Luigi; Tonner, Peter; Benhaoua, Hamina; Roesner, Jan Patrick; Bein, Berthold; Hanouz, Luc; Tenbrinck, Rob; Bogers, Ad J J C; Mik, Bert G; Coiffic, Alain; Renner, Jochen; Steinfath, Markus; Francksen, Helga; Broch, Ole; Haneya, Assad; Schaller, Manuella; Guinet, Patrick; Daviet, Lauren; Brianchon, Corinne; Rosier, Sebastien; Lehot, Jean-Jacques; Paarmann, Hauke; Schön, Julika; Hanke, Thorsten; Ettel, Joachym; Olsson, Silke; Klotz, Stefan; Samet, Amir; Laurinenas, Giedrius; Thibaud, Adrien; Cristinar, Mircea; Collanges, Olivier; Levy, François; Rossaint, Rolf; Stevanovic, Ana; Schaelte, Gereon; Stoppe, Christian; Hamou, Nora Ait; Hariri, Sarah; Quessard, Astrid; Carillion, Aude; Morin, Hélène; Silleran, Jacqueline; Robert, David; Crouzet, Anne-Sophie; Zacharowski, Kai; Reyher, Christian; Iken, Sonja; Weber, Nina C; Hollmann, Marcus; Eberl, Susanne; Carriero, Giovanni; Collacchi, Daria; Di Persio, Alessandra; Fourcade, Olivier; Bergt, Stefan; Alms, Angela

    2017-12-01

    Ischemic myocardial damage accompanying coronary artery bypass graft surgery remains a clinical challenge. We investigated whether xenon anesthesia could limit myocardial damage in coronary artery bypass graft surgery patients, as has been reported for animal ischemia models. In 17 university hospitals in France, Germany, Italy, and The Netherlands, low-risk elective, on-pump coronary artery bypass graft surgery patients were randomized to receive xenon, sevoflurane, or propofol-based total intravenous anesthesia for anesthesia maintenance. The primary outcome was the cardiac troponin I concentration in the blood 24 h postsurgery. The noninferiority margin for the mean difference in cardiac troponin I release between the xenon and sevoflurane groups was less than 0.15 ng/ml. Secondary outcomes were the safety and feasibility of xenon anesthesia. The first patient included at each center received xenon anesthesia for practical reasons. For all other patients, anesthesia maintenance was randomized (intention-to-treat: n = 492; per-protocol/without major protocol deviation: n = 446). Median 24-h postoperative cardiac troponin I concentrations (ng/ml [interquartile range]) were 1.14 [0.76 to 2.10] with xenon, 1.30 [0.78 to 2.67] with sevoflurane, and 1.48 [0.94 to 2.78] with total intravenous anesthesia [per-protocol]). The mean difference in cardiac troponin I release between xenon and sevoflurane was -0.09 ng/ml (95% CI, -0.30 to 0.11; per-protocol: P = 0.02). Postoperative cardiac troponin I release was significantly less with xenon than with total intravenous anesthesia (intention-to-treat: P = 0.05; per-protocol: P = 0.02). Perioperative variables and postoperative outcomes were comparable across all groups, with no safety concerns. In postoperative cardiac troponin I release, xenon was noninferior to sevoflurane in low-risk, on-pump coronary artery bypass graft surgery patients. Only with xenon was cardiac troponin I release less than with total intravenous

  5. Is general anesthesia a risk for myocardium? Effect of anesthesia on myocardial function as assessed by cardiac troponin-i in two different groups (isofluran+N2O inhalation and propofol+fentanyl iv anesthesia

    Directory of Open Access Journals (Sweden)

    Demet Dogan Erol

    2007-11-01

    Full Text Available Demet Dogan Erol1, Ibrahim Ozen21Department of Anaesthesiology and Reanimation, School of Medicine, Kocatepe University, Afyonkarahisar, Turkey; 2Department of Anaesthesiology and Reanimation, Karadeniz Technical University Faculty of Medicine, Trabzon, TurkeyBackground and objectives: Peroperative myocardial infarction (MI is the most common cause of morbidity and mortality. What is the role of general anesthesia in this process? Is general anesthesia a risk for myocardial infarction? The present study was designed to determine whether the measurement of serum levels of cardiac troponin I (cTnI, a highly sensitive and specific marker for cardiac injury, would help establish the diagnosis of myocardial infarction in two different types of anesthesia.Method: Elective abdominal hysterectomy was planned with the permission of the ethic committee in 40 patients who were 20–45 years range, in ASA-I group, and have a Goldman Cardiac Risk Index-0. The patients were divided into two groups. Isoflurane + N2O was administrated to first group, and Propofol + Fentanyl to second group. cTnI levels were determined before anesthesia, after induction before surgery and 9 hours after the second period respectively.Results: There was no significant difference between the groups by the means of demographic properties, hemodynamic parameters and cTnI levels, and the cTnI levels were determined under the basal levels in all samples.Conclusion: General anesthesia is not a risk for myocardial infarction to state eliminating risk factors and protection hemodynamia cardiac.Keywords: cardiac troponin-I, myocardial infarction, isofluran + N2O inhalation anesthesia, propofol + fentanyl intravenous anesthesia.

  6. High order depletion sensitivity analysis

    International Nuclear Information System (INIS)

    Naguib, K.; Adib, M.; Morcos, H.N.

    2002-01-01

    A high order depletion sensitivity method was applied to calculate the sensitivities of build-up of actinides in the irradiated fuel due to cross-section uncertainties. An iteration method based on Taylor series expansion was applied to construct stationary principle, from which all orders of perturbations were calculated. The irradiated EK-10 and MTR-20 fuels at their maximum burn-up of 25% and 65% respectively were considered for sensitivity analysis. The results of calculation show that, in case of EK-10 fuel (low burn-up), the first order sensitivity was found to be enough to perform an accuracy of 1%. While in case of MTR-20 (high burn-up) the fifth order was found to provide 3% accuracy. A computer code SENS was developed to provide the required calculations

  7. Myofilament Calcium Sensitivity: Mechanistic Insight into TnI Ser-23/24 and Ser-150 Phosphorylation Integration

    Directory of Open Access Journals (Sweden)

    Hussam E Salhi

    2016-12-01

    Full Text Available Troponin I (TnI is a major regulator of cardiac muscle contraction and relaxation. During physiological and pathological stress, TnI is differentially phosphorylated at multiple residues through different signaling pathways to match cardiac function to demand. The combination of these TnI phosphorylations can exhibit an expected or unexpected functional integration, whereby the function of two phosphorylations are different than that predicted from the combined function of each individual phosphorylation alone. We have shown that TnI Ser-23/24 and Ser-150 phosphorylation exhibit functional integration and are simultaneously increased in response to cardiac stress. In the current study, we investigated the functional integration of TnI Ser-23/24 and Ser-150 to alter cardiac contraction. We hypothesized that Ser-23/24 and Ser-150 phosphorylation each utilize distinct molecular mechanisms to alter the TnI binding affinity within the thin filament. Mathematical modeling predicts that Ser-23/24 and Ser-150 phosphorylation affect different TnI affinities within the thin filament to distinctly alter the Ca2+-binding properties of troponin. Protein binding experiments validate this assertion by demonstrating pseudo-phosphorylated Ser-150 decreases the affinity of isolated TnI for actin, whereas Ser-23/24 pseudo-phosphorylation is not different from unphosphorylated. Thus, our data supports that TnI Ser-23/24 affects TnI-TnC binding, while Ser-150 phosphorylation alters TnI-actin binding. By measuring force development in troponin-exchanged skinned myocytes, we demonstrate that the Ca2+ sensitivity of force is directly related to the amount of phosphate present on TnI. Furthermore, we demonstrate that Ser-150 pseudo-phosphorylation blunts Ser-23/24-mediated decreased Ca2+-sensitive force development whether on the same or different TnI molecule. Therefore, TnI phosphorylations can integrate across troponins along the myofilament. These data demonstrate

  8. Serum cardiac troponin I in canine syncope and seizures.

    Science.gov (United States)

    Dutton, E; Dukes-McEwan, J; Cripps, P J

    2017-02-01

    To determine if serum cardiac troponin I (cTnI) concentration distinguishes between cardiogenic syncope and collapsing dogs presenting with either generalized epileptic seizures (both with and without cardiac disease) or vasovagal syncope. Seventy-nine prospectively recruited dogs, grouped according to aetiology of collapse: generalized epileptic seizures (group E), cardiogenic syncope (group C), dogs with both epileptic seizures and cardiac disease (group B), vasovagal syncope (group V) or unclassified (group U). Most patients had ECG (n = 78), echocardiography (n = 78) and BP measurement (n = 74) performed. Dogs with a history of intoxications, trauma, evidence of metabolic disorders or renal insufficiency (based on serum creatinine concentrations >150 μmol/L and urine specific gravity disease) or vasovagal syncope. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. The clinical value of determination of serum troponin I and hypersensitive C-reactive protein around extracorporeal circulation

    International Nuclear Information System (INIS)

    Wang Rui; Cao Yong; Yan Ji

    2005-01-01

    To explore the clinical value of determination of serum troponin I (cTnI) and hyper-sensitive C-reactive protein(hs-CRP) around extracorporeal circulation, cTnI and hs-CRP were determined in 46 patients with congenital heart disease before and after the surgery (0, 24h, 3d, 7d, 15d respectively). At the same time, electrocardiogram(ECG), hemo dynamics and other adverse events were recorded. Before the surgery results of cTnI and hs-CRP were in nor- mal range, wheraas after surgery the level of cTnI went up, reached its peak at 24h, and returned normal on d7. The level of hs-CRP begin to increase at 24h, returned normal on dT. Its level was higher in patients with postoperative infection than that in patients without infection, however, it returned normal after anti-inflammatory treatment. Therefore, cTnI and hs-CRP may be taken as diagnostic criteria of prognosis in patient after extracorporea circulation surgery. Postoperative infection around extracorporeal circulation surgery could be prevented by monitring hs-CRP concentration. (authors)

  10. A high-sensitivity neutron counter and waste-drum counting with the high-sensitivity neutron instrument

    International Nuclear Information System (INIS)

    Hankins, D.E.; Thorngate, J.H.

    1993-04-01

    At Lawrence Livermore National Laboratory (LLNL), a highly sensitive neutron counter was developed that can detect and accurately measure the neutrons from small quantities of plutonium or from other low-level neutron sources. This neutron counter was originally designed to survey waste containers leaving the Plutonium Facility. However, it has proven to be useful in other research applications requiring a high-sensitivity neutron instrument

  11. High-Sensitivity GaN Microchemical Sensors

    Science.gov (United States)

    Son, Kyung-ah; Yang, Baohua; Liao, Anna; Moon, Jeongsun; Prokopuk, Nicholas

    2009-01-01

    Systematic studies have been performed on the sensitivity of GaN HEMT (high electron mobility transistor) sensors using various gate electrode designs and operational parameters. The results here show that a higher sensitivity can be achieved with a larger W/L ratio (W = gate width, L = gate length) at a given D (D = source-drain distance), and multi-finger gate electrodes offer a higher sensitivity than a one-finger gate electrode. In terms of operating conditions, sensor sensitivity is strongly dependent on transconductance of the sensor. The highest sensitivity can be achieved at the gate voltage where the slope of the transconductance curve is the largest. This work provides critical information about how the gate electrode of a GaN HEMT, which has been identified as the most sensitive among GaN microsensors, needs to be designed, and what operation parameters should be used for high sensitivity detection.

  12. Toward Protein Structure In Situ: Comparison of Two Bifunctional Rhodamine Adducts of Troponin C

    Science.gov (United States)

    Julien, Olivier; Sun, Yin-Biao; Knowles, Andrea C.; Brandmeier, Birgit D.; Dale, Robert E.; Trentham, David R.; Corrie, John E. T.; Sykes, Brian D.; Irving, Malcolm

    2007-01-01

    As part of a program to develop methods for determining protein structure in situ, sTnC was labeled with a bifunctional rhodamine (BR or BSR), cross-linking residues 56 and 63 of its C-helix. NMR spectroscopy of the N-terminal domain of BSR-labeled sTnC in complex with Ca2+ and the troponin I switch peptide (residues 115–131) showed that BSR labeling does not significantly affect the secondary structure of the protein or its dynamics in solution. BR-labeling was previously shown to have no effect on the solution structure of this complex. Isometric force generation in isolated demembranated fibers from rabbit psoas muscle into which BR- or BSR-labeled sTnC had been exchanged showed reduced Ca2+-sensitivity, and this effect was larger with the BSR label. The orientation of rhodamine dipoles with respect to the fiber axis was determined by polarized fluorescence. The mean orientations of the BR and BSR dipoles were almost identical in relaxed muscle, suggesting that both probes accurately report the orientation of the C-helix to which they are attached. The BSR dipole had smaller orientational dispersion, consistent with less flexible linkers between the rhodamine dipole and cysteine-reactive groups. PMID:17483167

  13. Restricted N-terminal truncation of cardiac troponin T: a novel mechanism for functional adaptation to energetic crisis.

    Science.gov (United States)

    Feng, Han-Zhong; Biesiadecki, Brandon J; Yu, Zhi-Bin; Hossain, M Moazzem; Jin, J-P

    2008-07-15

    The N-terminal variable region of cardiac troponin T (TnT) is a regulatory structure that can be selectively removed during myocardial ischaemia reperfusion by mu-calpain proteolysis. Here we investigated the pathophysiological significance of this post-translational modification that removes amino acids 1-71 of cardiac TnT. Working heart preparations were employed to study rat acute myocardial infarction and transgenic mouse hearts over-expressing the N-terminal truncated cardiac TnT (cTnT-ND). Ex vivo myocardial infarction by ligation of the left anterior descending coronary artery induced heart failure and produced cTnT-ND not only in the infarct but also in remote zones, including the right ventricular free wall, indicating a whole organ response in the absence of systemic neurohumoral mechanisms. Left ventricular pressure overload in mouse working hearts produced increased cTnT-ND in both ventricles, suggesting a role of haemodynamic stress in triggering an acute whole organ proteolytic regulation. Transgenic mouse hearts in which the endogenous intact cardiac TnT was partially replaced by cTnT-ND showed lowered contractile velocity. When afterload increased from 55 mmHg to 90 mmHg, stroke volume decreased in the wild type but not in the transgenic mouse hearts. Correspondingly, the left ventricular rapid-ejection time of the transgenic mouse hearts was significantly longer than that of wild type hearts, especially at high afterload. The restricted deletion of the N-terminal variable region of cardiac troponin T demonstrates a novel mechanism by which the thin filament regulation adapts to sustain cardiac function under stress conditions.

  14. The use of cell cycle arrest biomarkers in the early detection of acute kidney injury. Is this the new renal troponin?

    Science.gov (United States)

    Ortega, Luis M; Heung, Michael

    2018-04-05

    Acute kidney injury (AKI) has a high prevalence in critical care patients. Early detection might prevent patients from developing chronic kidney disease and requirement for renal replacement therapy. If we compare AKI with acute coronary syndrome, in which an increase in cardiac troponin may trigger early diagnosis and therapeutic intervention, we could extrapolate a similar technique in patients with early AKI without changes in urinary frequency or serum creatinine. The objective is to identify biomarker-positive, creatinine-negative patients that would allow therapeutic interventions to be initiated before finding changes in serum creatinine, preventing kidney damage. Tissue inhibitor of metalloproteinase 2 and insulin-like growth factor binding protein 7 are cell cycle arrest biomarkers that have demonstrated, in recent clinical trials, to have good sensitivity and specificity for early detection of AKI. Other recent studies have shown that the joint use of these biomarkers with serum creatinine and urine production could improve the prognosis of AKI in critical patients. The application of these biomarkers in clinical practice would enable the early identification of patients at risk of AKI, establishing interventions that would improve the survival of renal function. Copyright © 2017 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  15. Validation, optimisation, and application data in support of the development of a targeted selected ion monitoring assay for degraded cardiac troponin T

    Directory of Open Access Journals (Sweden)

    Alexander S. Streng

    2016-06-01

    Full Text Available Cardiac troponin T (cTnT fragmentation in human serum was investigated using a newly developed targeted selected ion monitoring assay, as described in the accompanying article: “Development of a targeted selected ion monitoring assay for the elucidation of protease induced structural changes in cardiac troponin T” [1]. This article presents data describing aspects of the validation and optimisation of this assay. The data consists of several figures, an excel file containing the results of a sequence identity search, and a description of the raw mass spectrometry (MS data files, deposited in the ProteomeXchange repository with id PRIDE: http://www.ebi.ac.uk/pride/archive/projects/PXD003187.

  16. High-Sensitivity Spectrophotometry.

    Science.gov (United States)

    Harris, T. D.

    1982-01-01

    Selected high-sensitivity spectrophotometric methods are examined, and comparisons are made of their relative strengths and weaknesses and the circumstances for which each can best be applied. Methods include long path cells, noise reduction, laser intracavity absorption, thermocouple calorimetry, photoacoustic methods, and thermo-optical methods.…

  17. Cardiac troponin T and CK-MB mass release after visually successful percutaneous transluminal coronary angioplasty in stable angina pectoris

    DEFF Research Database (Denmark)

    Ravkilde, J; Nissen, H; Mickley, H

    1994-01-01

    The incidence of cardiac troponin T (Tn-T) and creatine kinase (CK) isoenzyme MB mass release was studied in 23 patients with stable angina pectoris undergoing visually successful percutaneous transluminal coronary angioplasty (PTCA). Serial blood samples were drawn for measurement of serum Tn...

  18. Papel da dosagem seriada de troponina nos pacientes com suspeita de contusão miocárdica após trauma torácico fechado The role of serial measurement of troponin in patients with a suspected myocardial injury after chest trauma

    Directory of Open Access Journals (Sweden)

    Thiago Domingos Corrêa

    2007-06-01

    myocardial injury troponin I and troponin T have stood out. Troponins are proteins of the citocellular apparatus, released into the bloodstream only after the disruption of myocytes cellular membrane. Therefore they are highly specific to detect myocardial injuries. CONTENTS: We performed a clinical review using the electronic databases MedLine and LILACS from January 1980 to November 2006 about the importance of a serial measurement of troponin I and T as a diagnostic tool as well as predictor of unfavorable clinical outcome in patients with myocardial contusion after a blunt chest trauma. CONCLUSIONS: Although troponins I and T are more specific than usual biomarkers CKMB and CK, these two first biomarkers show a low sensitivity and positive predictive value to diagnosis myocardial contusion. Patients with ECG abnormalities, troponins elevations or both should remain in an intensive care unit (ICU for at least 24 hours, period in which they cam develop most of the complications related to myocardial contusion.

  19. High sensitivity optical molecular imaging system

    Science.gov (United States)

    An, Yu; Yuan, Gao; Huang, Chao; Jiang, Shixin; Zhang, Peng; Wang, Kun; Tian, Jie

    2018-02-01

    Optical Molecular Imaging (OMI) has the advantages of high sensitivity, low cost and ease of use. By labeling the regions of interest with fluorescent or bioluminescence probes, OMI can noninvasively obtain the distribution of the probes in vivo, which play the key role in cancer research, pharmacokinetics and other biological studies. In preclinical and clinical application, the image depth, resolution and sensitivity are the key factors for researchers to use OMI. In this paper, we report a high sensitivity optical molecular imaging system developed by our group, which can improve the imaging depth in phantom to nearly 5cm, high resolution at 2cm depth, and high image sensitivity. To validate the performance of the system, special designed phantom experiments and weak light detection experiment were implemented. The results shows that cooperated with high performance electron-multiplying charge coupled device (EMCCD) camera, precision design of light path system and high efficient image techniques, our OMI system can simultaneously collect the light-emitted signals generated by fluorescence molecular imaging, bioluminescence imaging, Cherenkov luminance and other optical imaging modality, and observe the internal distribution of light-emitting agents fast and accurately.

  20. Molecular and immunohistochemical analyses of cardiac troponin T during cardiac development in the Mexican axolotl, Ambystoma mexicanum.

    Science.gov (United States)

    Zhang, C; Pietras, K M; Sferrazza, G F; Jia, P; Athauda, G; Rueda-de-Leon, E; Rveda-de-Leon, E; Maier, J A; Dube, D K; Lemanski, S L; Lemanski, L F

    2007-01-01

    The Mexican axolotl, Ambystoma mexicanum, is an excellent animal model for studying heart development because it carries a naturally occurring recessive genetic mutation, designated gene c, for cardiac nonfunction. The double recessive mutants (c/c) fail to form organized myofibrils in the cardiac myoblasts resulting in hearts that fail to beat. Tropomyosin expression patterns have been studied in detail and show dramatically decreased expression in the hearts of homozygous mutant embryos. Because of the direct interaction between tropomyosin and troponin T (TnT), and the crucial functions of TnT in the regulation of striated muscle contraction, we have expanded our studies on this animal model to characterize the expression of the TnT gene in cardiac muscle throughout normal axolotl development as well as in mutant axolotls. In addition, we have succeeded in cloning the full-length cardiac troponin T (cTnT) cDNA from axolotl hearts. Confocal microscopy has shown a substantial, but reduced, expression of TnT protein in the mutant hearts when compared to normal during embryonic development. 2006 Wiley-Liss, Inc.

  1. Elevated Plasma Cardiac Troponin T Levels Caused by Skeletal Muscle Damage in Pompe Disease.

    Science.gov (United States)

    Wens, Stephan C A; Schaaf, Gerben J; Michels, Michelle; Kruijshaar, Michelle E; van Gestel, Tom J M; In 't Groen, Stijn; Pijnenburg, Joon; Dekkers, Dick H W; Demmers, Jeroen A A; Verdijk, Lex B; Brusse, Esther; van Schaik, Ron H N; van der Ploeg, Ans T; van Doorn, Pieter A; Pijnappel, W W M Pim

    2016-02-01

    Elevated plasma cardiac troponin T (cTnT) levels in patients with neuromuscular disorders may erroneously lead to the diagnosis of acute myocardial infarction or myocardial injury. In 122 patients with Pompe disease, the relationship between cTnT, cardiac troponin I, creatine kinase (CK), CK-myocardial band levels, and skeletal muscle damage was assessed. ECG and echocardiography were used to evaluate possible cardiac disease. Patients were divided into classic infantile, childhood-onset, and adult-onset patients. cTnT levels were elevated in 82% of patients (median 27 ng/L, normal values normal in all patients, whereas CK-myocardial band levels were increased in 59% of patients. cTnT levels correlated with CK levels in all 3 subgroups (Pmass index measured with echocardiography was normal in all the 3 subgroups. cTnT mRNA expression in skeletal muscle was not detectable in controls but was strongly induced in patients with Pompe disease. cTnT protein was identified by mass spectrometry in patient-derived skeletal muscle tissue. Elevated plasma cTnT levels in patients with Pompe disease are associated with skeletal muscle damage, rather than acute myocardial injury. Increased cTnT levels in Pompe disease and likely other neuromuscular disorders should be interpreted with caution to avoid unnecessary cardiac interventions. © 2016 American Heart Association, Inc.

  2. Single and multiple cardiovascular biomarkers in subjects without a previous cardiovascular event

    DEFF Research Database (Denmark)

    Pareek, Manan; Bhatt, Deepak L; Vaduganathan, Muthiah

    2017-01-01

    Aims To assess the incremental value of biomarkers, including N-terminal prohormone of brain natriuretic peptide (NT-proBNP), high-sensitivity troponin T (hs-TnT), high-sensitivity C-reactive protein (hs-CRP), interleukin-6 (IL-6), growth differentiation factor 15 (GDF-15), and procollagen type 1...

  3. Commutability of possible external quality assessment materials for cardiac troponin measurement.

    Directory of Open Access Journals (Sweden)

    Shunli Zhang

    Full Text Available The measurement of cardiac troponin is crucial in the diagnosis of myocardial infarction. The performance of troponin measurement is most conveniently monitored by external quality assessment (EQA programs. The commutability of EQA samples is often unknown and the effectiveness of EQA programs is limited.Commutability of possible EQA materials was evaluated. Commercial control materials used in an EQA program, human serum pools prepared from patient samples, purified analyte preparations, swine sera from model animals and a set of patient samples were measured for cTnI with 4 assays including Abbott Architect, Beckman Access, Ortho Vitros and Siemens Centaur. The measurement results were logarithm-transformed, and the transformed data for patient samples were pairwise analyzed with Deming regression and 95% prediction intervals were calculated for each pair of assays. The commutability of the materials was evaluated by comparing the logarithmic results of the materials with the limits of the intervals. Matrix-related biases were estimated for noncommutable materials. The impact of matrix-related bias on EQA was analyzed and a possible correction for the bias was proposed.Human serum pools were commutable for all assays; purified analyte preparations were commutable for 2 of the 6 assay pairs; commercial control materials and swine sera were all noncommutable; swine sera showed no reactivity to Vitros assay. The matrix-related biases for noncommutable materials ranged from -83% to 944%. Matrix-related biases of the EQA materials caused major abnormal between-assay variations in the EQA program and correction of the biases normalized the variations.Commutability of materials has major impact on the effectiveness of EQA programs for cTnI measurement. Human serum pools prepared from patient samples are commutable and other materials are mostly noncommutable. EQA programs should include at least one human serum pool to allow proper interpretation of

  4. Subclinical Atherosclerosis, Cardiac and Kidney Function, Heart Failure, and Dementia in the Very Elderly.

    Science.gov (United States)

    Kuller, Lewis H; Lopez, Oscar L; Gottdiener, John S; Kitzman, Dalane W; Becker, James T; Chang, Yuefang; Newman, Anne B

    2017-07-22

    Heart failure (HF) and dementia are major causes of disability and death among older individuals. Risk factors and biomarkers of HF may be determinants of dementia in the elderly. We evaluated the relationship between biomarkers of cardiovascular disease and HF and risk of dementia and death. Three hypotheses were tested: (1) higher levels of high-sensitivity cardiac troponin T, N-terminal of prohormone brain natriuretic peptide, and cystatin C predict risk of death, cardiovascular disease, HF, and dementia; (2) higher levels of cardiovascular disease biomarkers are associated with increased risk of HF and then secondary increased risk of dementia; and (3) risk of dementia is lower among participants with a combination of lower coronary artery calcium, atherosclerosis, and lower high-sensitivity cardiac troponin T (myocardial injury). The Cardiovascular Health Study Cognition Study was a continuation of the Cardiovascular Health Study limited to the Pittsburgh, PA, center from 1998-1999 to 2014. In 1992-1994, 924 participants underwent magnetic resonance imaging of the brain. There were 199 deaths and 116 developed dementia before 1998-1999. Of the 609 participants eligible for the Pittsburgh Cardiovascular Health Study Cognition Study, 87.5% (n=532) were included in the study. There were 120 incident HF cases and 72% had dementia. In 80 of 87, dementia preceded HF. A combination of low coronary artery calcium score and low high-sensitivity cardiac troponin T was significantly associated with reduced risk of dementia and HF. Most participants with HF had dementia but with onset before HF. Lower high-sensitivity cardiac troponin T and coronary artery calcium was associated with low risk of dementia based on a small number of events. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00005133. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  5. Changes in force and calcium sensitivity in the developing avian heart.

    Science.gov (United States)

    Godt, R E; Fogaça, R T; Nosek, T M

    1991-11-01

    The aim of this study was to characterize the development of the contractile properties of intact and chemically skinned muscle from chicken heart and to compare these characteristics with those of developing mammalian heart reported by others. Small trabeculae were dissected from left ventricles of Arbor Acre chickens between embryonic day 7 and young adulthood (7 weeks post-hatching). At all ages, increasing extracellular calcium (0.45-3.6 mM) progressively increased twitch force of electrically stimulated trabeculae. Twitch force at 1.8 mM extracellular calcium, normalized to cross-sectional area, increased to a maximum at 1 day post-hatching, remained constant through 3 weeks post-hatching, but then decreased at 7 weeks post-hatching. The maximal calcium-activated force of trabeculae chemically skinned with Triton X-100 detergent increased to a maximum 2 days before the time of hatching and was not significantly changed up to 7 weeks post-hatching. Over the ages studied, average twitch force in 1.8 mM calcium was between 26 and 66% of maximal calcium-activated force after skinning, suggesting that the contractile apparatus is not fully activated during the twitch in normal Ringer. In skinned trabeculae, the calcium sensitivity of the contractile apparatus was higher in the embryo than in the young adult. These age-dependent changes in calcium sensitivity are correlated with isoform switching in troponin T. A decrease in pH from 7.0 to 6.5 decreased the calcium sensitivity of the contractile apparatus to a greater degree in skinned trabeculae from young adult hearts than in those from embryonic hearts. This change in susceptibility to acidosis is temporally associated with isoform switching in troponin I.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Highly Sensitive Optical Receivers

    CERN Document Server

    Schneider, Kerstin

    2006-01-01

    Highly Sensitive Optical Receivers primarily treats the circuit design of optical receivers with external photodiodes. Continuous-mode and burst-mode receivers are compared. The monograph first summarizes the basics of III/V photodetectors, transistor and noise models, bit-error rate, sensitivity and analog circuit design, thus enabling readers to understand the circuits described in the main part of the book. In order to cover the topic comprehensively, detailed descriptions of receivers for optical data communication in general and, in particular, optical burst-mode receivers in deep-sub-µm CMOS are presented. Numerous detailed and elaborate illustrations facilitate better understanding.

  7. Cardiac troponin T predicts occult coronary artery stenosis in patients with chronic kidney disease at the start of renal replacement therapy.

    Science.gov (United States)

    Hayashi, Terumasa; Obi, Yoshitsugu; Kimura, Tomonori; Iio, Ken-Ichiro; Sumitsuji, Satoru; Takeda, Yoshihiro; Nagai, Yoshiyuki; Imai, Enyu

    2008-09-01

    The high prevalence of asymptomatic coronary artery stenosis (CAS) in chronic kidney disease (CKD) has emerged as an important predictor of outcome. However, diagnostic tools that can identify asymptomatic CAS have not yet been established. We investigated whether asymptomatic patients at the initiation of renal replacement therapy (RRT) could be screened using cardiac troponin T (cTnT) and atherosclerotic surrogate markers such as ankle-brachial blood pressure index (ABPI) and intima-media thickness (IMT). Among 142 patients who were about to start RRT, 60 who were asymptomatic underwent coronary evaluation by multi-slice computed tomography (MSCT) and/or coronary angiography (CAG). CAG diagnosed 35 patients (43.8%) as CAS positive and 27 of them had multi-vessel disease. Factors associated with CAS were smoking, elevated cTnT, low ABPI and high IMT. Moreover, the severity of CAS was associated with smoking, cTnT and ABPI. Stepwise logistic regression analyses revealed that cTnT was a powerful predictor of asymptomatic multi-vessel CAS. Receiver operating characteristic analysis documented the usefulness of cTnT as a screening tool with a cut-off point 0.05 ng/ml. The optimal screening tool for multi-vessel CAS was cTnT (sensitivity, 92.6%; 95% CI, 82.7-99.9; specificity, 63.6%; 95% CI, 47.2-80.0). We concluded that cTnT should be measured as part of a strategy for detecting asymptomatic CAS, especially multi-vessel disease in patients with CKD at the start of RRT.

  8. A new score for the diagnosis of acute coronary syndrome in acute chest pain with non-diagnostic ECG and normal troponin.

    Science.gov (United States)

    Boubaker, Hamdi; Grissa, Mohamed Habib; Beltaief, Kaouther; Amor, Mohamed Haj; Mdimagh, Zouhaier; Boukhris, Amor; Ben Amor, Mehdi; Dridi, Zohra; Letaief, Mondher; Bouida, Wahid; Boukef, Riadh; Najjar, Fadhel; Nouira, Semir

    2015-10-01

    Acute coronary syndrome (ACS) represents a difficult diagnostic challenge in patients with undifferentiated chest pain. There is a need for a valid clinical score to improve diagnostic accuracy. To compare the performance of a model combining the Thrombolysis in Myocardial Infarction (TIMI) score and a score describing chest pain (ACS diagnostic score: ACSD score) with that of both scores alone in the diagnosis of ACS in ED patients with chest pain associated with a non-diagnostic ECG and normal troponin. In this observational cohort study, we enrolled 809 patients admitted to a chest pain unit with normal ECG and normal troponin. They were prospectively evaluated in order to calculate TIMI score, chest pain characteristics score and ACSD score. Diagnosis of ACS was the primary outcome and defined on the basis of 2 cardiologists after reviewing the patient medical records and follow-up data. Mortality and major cardiovascular events were followed for 1 month for patients discharged directly from ED. Discriminative power of scores was evaluated by the area under the ROC curve. ACS was confirmed in 90 patients (11.1%). The area under the ROC curve for ACSD score was 0.85 (95% CI 0.80 to 0.90) compared with 0.74 (95% CI 0.67 to 0.81) for TIMI and 0.79 (95% CI 0.74 to 0.84) for chest pain characteristics score. A threshold value of 9 appeared to optimise sensitivity (92%) and negative predictive value (99%) without excessively compromising specificity (62%) and positive predictive value (23%). The ACSD score showed a good discrimination performance and an excellent negative predictive value which allows safely ruling out ACS in ED patients with undifferentiated chest pain. Our findings should be validated in a larger multicentre study. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  9. Ascending-ramp biphasic waveform has a lower defibrillation threshold and releases less troponin I than a truncated exponential biphasic waveform.

    Science.gov (United States)

    Huang, Jian; Walcott, Gregory P; Ruse, Richard B; Bohanan, Scott J; Killingsworth, Cheryl R; Ideker, Raymond E

    2012-09-11

    We tested the hypothesis that the shape of the shock waveform affects not only the defibrillation threshold but also the amount of cardiac damage. Defibrillation thresholds were determined for 11 waveforms-3 ascending-ramp waveforms, 3 descending-ramp waveforms, 3 rectilinear first-phase biphasic waveforms, a Gurvich waveform, and a truncated exponential biphasic waveform-in 6 pigs with electrodes in the right ventricular apex and superior vena cava. The ascending, descending, and rectilinear waveforms had 4-, 8-, and 16-millisecond first phases and a 3.5-millisecond rectilinear second phase that was half the voltage of the first phase. The exponential biphasic waveform had a 60% first-phase and a 50% second-phase tilt. In a second study, we attempted to defibrillate after 10 seconds of ventricular fibrillation with a single ≈30-J shock (6 pigs successfully defibrillated with 8-millisecond ascending, 8-millisecond rectilinear, and truncated exponential biphasic waveforms). Troponin I blood levels were determined before and 2 to 10 hours after the shock. The lowest-energy defibrillation threshold was for the 8-milliseconds ascending ramp (14.6±7.3 J [mean±SD]), which was significantly less than for the truncated exponential (19.6±6.3 J). Six hours after shock, troponin I was significantly less for the ascending-ramp waveform (0.80±0.54 ng/mL) than for the truncated exponential (1.92±0.47 ng/mL) or the rectilinear waveform (1.17±0.45 ng/mL). The ascending ramp has a significantly lower defibrillation threshold and at ≈30 J causes 58% less troponin I release than the truncated exponential biphasic shock. Therefore, the shock waveform affects both the defibrillation threshold and the amount of cardiac damage.

  10. Troponin release following endurance exercise: is inflammation the cause? a cardiovascular magnetic resonance study

    Directory of Open Access Journals (Sweden)

    O'Hanlon Rory

    2010-07-01

    Full Text Available Abstract Background The aetiology and clinical significance of troponin release following endurance exercise is unclear but may be due to transient myocardial inflammation. Cardiovascular magnetic resonance (CMR affords us the opportunity to evaluate the presence of myocardial inflammation and focal fibrosis and is the ideal imaging modality to study this hypothesis. We sought to correlate the relationship between acute bouts of ultra endurance exercise leading to cardiac biomarkers elevation and the presence of myocardial inflammation and fibrosis using CMR. Methods 17 recreation athletes (33.5 +/- 6.5 years were studied before and after a marathon run with troponin, NTproBNP, and CMR. Specific imaging parameters to look for inflammation included T2 weighted images, and T1 weighted spin-echo images before and after an intravenous gadolinium-DTPA to detect myocardial hyperemia secondary to inflammation. Late gadolinium imaging was performed (LGE to detect any focal regions of replacement fibrosis. Results Eleven of the 17 participant had elevations of TnI above levels of cut off for myocardial infarction 6 hrs after the marathon (0.075 +/- 0.02, p = 0.007. Left ventricular volumes were reduced post marathon and a small increase in ejection fraction was noted (64+/- 1% pre, 67+/- 1.2% post, P = 0.014. Right ventricular volumes, stroke volume, and ejection fraction were unchanged post marathon. No athlete fulfilled criteria for myocardial inflammation based on current criteria. No regions of focal fibrosis were seen in any of the participants. Conclusion Exercise induced cardiac biomarker release is not associated with any functional changes by CMR or any detectable myocardial inflammation or fibrosis.

  11. Methylation-Sensitive High Resolution Melting (MS-HRM).

    Science.gov (United States)

    Hussmann, Dianna; Hansen, Lise Lotte

    2018-01-01

    Methylation-Sensitive High Resolution Melting (MS-HRM) is an in-tube, PCR-based method to detect methylation levels at specific loci of interest. A unique primer design facilitates a high sensitivity of the assays enabling detection of down to 0.1-1% methylated alleles in an unmethylated background.Primers for MS-HRM assays are designed to be complementary to the methylated allele, and a specific annealing temperature enables these primers to anneal both to the methylated and the unmethylated alleles thereby increasing the sensitivity of the assays. Bisulfite treatment of the DNA prior to performing MS-HRM ensures a different base composition between methylated and unmethylated DNA, which is used to separate the resulting amplicons by high resolution melting.The high sensitivity of MS-HRM has proven useful for detecting cancer biomarkers in a noninvasive manner in urine from bladder cancer patients, in stool from colorectal cancer patients, and in buccal mucosa from breast cancer patients. MS-HRM is a fast method to diagnose imprinted diseases and to clinically validate results from whole-epigenome studies. The ability to detect few copies of methylated DNA makes MS-HRM a key player in the quest for establishing links between environmental exposure, epigenetic changes, and disease.

  12. Cardiac troponin I levels in canine pyometra

    Directory of Open Access Journals (Sweden)

    Hagman Ragnvi

    2007-02-01

    Full Text Available Abstract Background Myocardial injury may contribute to unexpected deaths due to pyometra. To detect myocardial damage, measurement of cardiac troponin I (cTnI is currently the most sensitive and specific method. The aims of the present study were to evaluate presence of myocardial damage in canine pyometra by analysis of cTnI, to explore whether myocardial injury was associated with systemic inflammatory response syndrome (SIRS and to evaluate whether other clinical or laboratory parameters were associated with cTnI increase. Methods Preoperative plasma levels of cTnI were investigated in 58 female dogs with pyometra and 9 controls. The value of physical examination findings, haematological, serum biochemical and pro-inflammatory (CRP and TNF-α parameters as possible predictors of increased cTnI levels was also evaluated. Results Seven dogs with pyometra (12% and one control dog (11% had increased levels of cTnI. In the pyometra group, the levels ranged between 0.3–0.9 μg l-1 and in the control dog the level was 0.3 μg l-1. The cTnI levels did not differ significantly between the two groups. No cardiac abnormalities were evident on preoperative physical examinations. Four of the pyometra patients died within two weeks of surgery, of which two were examined post mortem. In one of these cases (later diagnosed with myocarditis and disseminated bacterial infection the cTnI levels increased from 0.9 μg l-1 preoperatively to 180 μg l-1 the following day when also heart arrhythmia was also detected. The other patient had cTnI levels of 0.7 μg l-1 with no detectable heart pathology post mortem. CTnI increase was not associated with presence of SIRS. There was a trend for the association of cTnI increase with increased mortality. No preoperative physical examination findings and few but unspecific laboratory parameters were associated with increased cTnI levels. Conclusion Increased cTnI levels were observed in 12% of the dogs with pyometra. The

  13. TNNI3K is a novel mediator of myofilament function and phosphorylates cardiac troponin I

    International Nuclear Information System (INIS)

    Wang, Hui; Wang, Lin; Song, Li; Zhang, Yan-Wan; Ye, Jue; Xu, Rui-Xia; Shi, Na; Meng, Xian-Min

    2013-01-01

    The phosphorylation of cardiac troponin I (cTnI) plays an important role in the contractile dysfunction associated with heart failure. Human cardiac troponin I-interacting kinase (TNNI3K) is a novel cardiac-specific functional kinase that can bind to cTnI in a yeast two-hybrid screen. The purpose of this study was to investigate whether TNNI3K can phosphorylate cTnI at specific sites and to examine whether the phosphorylation of cTnI caused by TNNI3K can regulate cardiac myofilament contractile function. Co-immunoprecipitation was performed to confirm that TNNI3K could interact with cTnI. Kinase assays further indicated that TNNI3K did not phosphorylate cTnI at Ser23/24 and Ser44, but directly phosphorylated Ser43 and Thr143 in vitro. The results obtained for adult rat cardiomyocytes also indicated that enhanced phosphorylation of cTnI at Ser43 and Thr143 correlated with rTNNI3K (rat TNNI3K) overexpression, and phosphorylation was reduced when rTNNI3K was knocked down. To determine the contractile function modulated by TNNI3K-mediated phosphorylation of cTnI, cardiomyocyte contraction was studied in adult rat ventricular myocytes. The contraction of cardiomyocytes increased with rTNNI3K overexpression and decreased with rTNNI3K knockdown. We conclude that TNNI3K may be a novel mediator of cTnI phosphorylation and contribute to the regulation of cardiac myofilament contraction function

  14. High blood pressure and visual sensitivity

    Science.gov (United States)

    Eisner, Alvin; Samples, John R.

    2003-09-01

    The study had two main purposes: (1) to determine whether the foveal visual sensitivities of people treated for high blood pressure (vascular hypertension) differ from the sensitivities of people who have not been diagnosed with high blood pressure and (2) to understand how visual adaptation is related to standard measures of systemic cardiovascular function. Two groups of middle-aged subjects-hypertensive and normotensive-were examined with a series of test/background stimulus combinations. All subjects met rigorous inclusion criteria for excellent ocular health. Although the visual sensitivities of the two subject groups overlapped extensively, the age-related rate of sensitivity loss was, for some measures, greater for the hypertensive subjects, possibly because of adaptation differences between the two groups. Overall, the degree of steady-state sensitivity loss resulting from an increase of background illuminance (for 580-nm backgrounds) was slightly less for the hypertensive subjects. Among normotensive subjects, the ability of a bright (3.8-log-td), long-wavelength (640-nm) adapting background to selectively suppress the flicker response of long-wavelength-sensitive (LWS) cones was related inversely to the ratio of mean arterial blood pressure to heart rate. The degree of selective suppression was also related to heart rate alone, and there was evidence that short-term changes of cardiovascular response were important. The results suggest that (1) vascular hypertension, or possibly its treatment, subtly affects visual function even in the absence of eye disease and (2) changes in blood flow affect retinal light-adaptation processes involved in the selective suppression of the flicker response from LWS cones caused by bright, long-wavelength backgrounds.

  15. Highly sensitive high resolution Raman spectroscopy using resonant ionization methods

    International Nuclear Information System (INIS)

    Owyoung, A.; Esherick, P.

    1984-05-01

    In recent years, the introduction of stimulated Raman methods has offered orders of magnitude improvement in spectral resolving power for gas phase Raman studies. Nevertheless, the inherent weakness of the Raman process suggests the need for significantly more sensitive techniques in Raman spectroscopy. In this we describe a new approach to this problem. Our new technique, which we call ionization-detected stimulated Raman spectroscopy (IDSRS), combines high-resolution SRS with highly-sensitive resonant laser ionization to achieve an increase in sensitivity of over three orders of magnitude. The excitation/detection process involves three sequential steps: (1) population of a vibrationally excited state via stimulated Raman pumping; (2) selective ionization of the vibrationally excited molecule with a tunable uv source; and (3) collection of the ionized species at biased electrodes where they are detected as current in an external circuit

  16. Molecular Defects in Cardiac Myofilament Ca2+-Regulation Due to Cardiomyopathy-Linked Mutations Can Be Reversed by Small Molecules Binding to Troponin

    Czech Academy of Sciences Publication Activity Database

    Sheehan, A.; Messer, A.E.; Papadaki, M.; Choudhry, A.; Křen, Vladimír; Biedermann, David; Blagg, B.; Khandelwal, A.; Marston, S.B.

    2018-01-01

    Roč. 9, MAR 27 2018 (2018), č. článku 243. ISSN 1664-042X R&D Projects: GA MZd(CZ) NV16-27317A Institutional support: RVO:61388971 Keywords : cardiomyopathy * sarcomeric protein mutations * troponin I phosphorylation OBOR OECD: Cardiac and Cardiovascular systems Impact factor: 4.134, year: 2016

  17. Troponin T and N-terminal pro B-Type natriuretic peptide and presence of coronary artery disease

    DEFF Research Database (Denmark)

    Mouridsen, Mette R; Sajadieh, Ahmad; Carlsen, Christian M

    2015-01-01

    BACKGROUND: We tested the effects of exercise intensity, sampling intervals, degree of coronary artery stenosis, and demographic factors on circulating N-terminal pro B-Type natriuretic peptide (NT-pro-BNP) and cardiac Troponin T (cTnT) in subjects suspected of coronary artery disease (CAD). MATE...... = 0.4067 p = 0.046). CONCLUSIONS: Baseline cTnT and ΔcTnT were found to be independently associated with CAD and also with exercise intensity in stable chest pain subjects. These properties were not identified for NT-pro-BNP....

  18. Oxidative stress and cardiomyocyte necrosis with elevated serum troponins: pathophysiologic mechanisms.

    Science.gov (United States)

    Robinson, Antwon D; Ramanathan, Kodangudi B; McGee, Jesse E; Newman, Kevin P; Weber, Karl T

    2011-08-01

    The progressive nature of heart failure is linked to multiple factors, including an ongoing loss of cardiomyocytes and necrosis. Necrotic cardiomyocytes leave behind several footprints: the spillage of their contents leading to elevations in serum troponins; and morphologic evidence of tissue repair with scarring. The pathophysiologic origins of cardiomyocyte necrosis relates to neurohormonal activation, including the adrenergic nervous system. Catecholamine-initiated excessive intracellular Ca accumulation and mitochondria Ca overloading in particular initiate a mitochondriocentric signal-transducer-effector pathway to necrosis and which includes the induction of oxidative stress and opening of their inner membrane permeability transition pore. Hypokalemia, ionized hypocalcemia and hypomagnesemia, where consequent elevations in parathyroid hormone further account for excessive intracellular Ca accumulation, hypozincemia and hyposelenemia each compromise metalloenzyme-based antioxidant defenses. The necrotic loss of cardiomyocytes and adverse structural remodeling of myocardium is related to the central role played by a mitochondriocentric pathway initiated by neurohormonal activation.

  19. Characterization and validation of new tools for measuring site-specific cardiac troponin I phosphorylation.

    Science.gov (United States)

    Thoemmes, Stephen F; Stutzke, Crystal A; Du, Yanmei; Browning, Michael D; Buttrick, Peter M; Walker, Lori A

    2014-01-31

    Phosphorylation of cardiac troponin I is a well established mechanism by which cardiac contractility is modulated. However, there are a number of phosphorylation sites on TnI which contribute singly or in combination to influence cardiac function. Accordingly, methods for accurately measuring site-specific TnI phosphorylation are needed. Currently, two strategies are employed: mass spectrometry, which is costly, difficult and has a low throughput; and Western blotting using phospho-specific antibodies, which is limited by the availability of reagents. In this report, we describe a cohort of new site-specific TnI phosphoantibodies, generated against physiologically relevant phosphorylation sites, that are superior to the current commercially available antibodies: to phospho-serine 22/23 which shows a >5-fold phospho-specificity for phosphorylated TnI; to phospho-serine 43, which has >3-fold phospho-specificity for phosphorylated TnI; and phospho-serine 150 which has >2-fold phospho-specificity for phosphorylated TnI. These new antibodies demonstrated greater sensitivity and specificity for the phosphorylated TnI than the most widely used commercially available reagents. For example, at a protein load of 20 μg of total cardiac extract, a commercially available antibody recognized both phosphorylated and dephosphorylated TnI to the same degree. At the same protein load our phospho-serine 22/23 antibody exhibited no cross-reactivity with dephosphorylated TnI. These new tools should allow a more accurate assessment and a better understanding of the role of TnI phosphorylation in the response of the heart to pathologic stress. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Hypertrophic cardiomyopathy-linked mutation in troponin T causes myofibrillar disarray and pro-arrhythmic action potential changes in human iPSC cardiomyocytes.

    Science.gov (United States)

    Wang, Lili; Kim, Kyungsoo; Parikh, Shan; Cadar, Adrian Gabriel; Bersell, Kevin R; He, Huan; Pinto, Jose R; Kryshtal, Dmytro O; Knollmann, Bjorn C

    2018-01-01

    Mutations in cardiac troponin T (TnT) are linked to increased risk of ventricular arrhythmia and sudden death despite causing little to no cardiac hypertrophy. Studies in mice suggest that the hypertrophic cardiomyopathy (HCM)-associated TnT-I79N mutation increases myofilament Ca sensitivity and is arrhythmogenic, but whether findings from mice translate to human cardiomyocyte electrophysiology is not known. To study the effects of the TnT-I79N mutation in human cardiomyocytes. Using CRISPR/Cas9, the TnT-I79N mutation was introduced into human induced pluripotent stem cells (hiPSCs). We then used the matrigel mattress method to generate single rod-shaped cardiomyocytes (CMs) and studied contractility, Ca handling and electrophysiology. Compared to isogenic control hiPSC-CMs, TnT-I79N hiPSC-CMs exhibited sarcomere disorganization, increased systolic function and impaired relaxation. The Ca-dependence of contractility was leftward shifted in mutation containing cardiomyocytes, demonstrating increased myofilament Ca sensitivity. In voltage-clamped hiPSC-CMs, TnT-I79N reduced intracellular Ca transients by enhancing cytosolic Ca buffering. These changes in Ca handling resulted in beat-to-beat instability and triangulation of the cardiac action potential, which are predictors of arrhythmia risk. The myofilament Ca sensitizer EMD57033 produced similar action potential triangulation in control hiPSC-CMs. The TnT-I79N hiPSC-CM model not only reproduces key cellular features of TnT-linked HCM such as myofilament disarray, hypercontractility and diastolic dysfunction, but also suggests that this TnT mutation causes pro-arrhythmic changes of the human ventricular action potential. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Retinal sensitivity and choroidal thickness in high myopia.

    Science.gov (United States)

    Zaben, Ahmad; Zapata, Miguel Á; Garcia-Arumi, Jose

    2015-03-01

    To estimate the association between choroidal thickness in the macular area and retinal sensitivity in eyes with high myopia. This investigation was a transversal study of patients with high myopia, all of whom had their retinal sensitivity measured with macular integrity assessment microperimetry. The choroidal thicknesses in the macular area were then measured by optical coherence tomography, and statistical correlations between their functionality and the anatomical structuralism, as assessed by both types of measurements, were analyzed. Ninety-six eyes from 77 patients with high myopia were studied. The patients had a mean age ± standard deviation of 38.9 ± 13.2 years, with spherical equivalent values ranging from -6.00 diopter to -20.00 diopter (8.74 ± 2.73 diopter). The mean central choroidal thickness was 159.00 ± 50.57. The mean choroidal thickness was directly correlated with sensitivity (r = 0.306; P = 0.004) and visual acuity but indirectly correlated with the spherical equivalent values and patient age. The mean sensitivity was not significantly correlated with the macular foveal thickness (r = -0.174; P = 0.101) or with the overall macular thickness (r = 0.103; P = 0.334); furthermore, the mean sensitivity was significantly correlated with visual acuity (r = 0.431; P < 0.001) and the spherical equivalent values (r = -0.306; P = 0.003). Retinal sensitivity in highly myopic eyes is directly correlated with choroidal thickness and does not seem to be associated with retinal thickness. Thus, in patients with high myopia, accurate measurements of choroidal thickness may provide more accurate information about this pathologic condition because choroidal thickness correlates to a greater degree with the functional parameters, patient age, and spherical equivalent values.

  2. Visualizing the principal component of 1H,15N-HSQC NMR spectral changes that reflect protein structural or functional properties: application to troponin C

    International Nuclear Information System (INIS)

    Robertson, Ian M.; Boyko, Robert F.; Sykes, Brian D.

    2011-01-01

    Laboratories often repeatedly determine the structure of a given protein under a variety of conditions, mutations, modifications, or in a number of states. This approach can be cumbersome and tedious. Given then a database of structures, identifiers, and corresponding 1 H, 15 N-HSQC NMR spectra for homologous proteins, we investigated whether structural information could be ascertained for a new homolog solely from its 1 H, 15 N-HSQC NMR spectrum. We addressed this question with two different approaches. First, we used a semi-automated approach with the program, ORBplus. ORBplus looks for patterns in the chemical shifts and correlates these commonalities to the explicit property of interest. ORBplus ranks resonances based on consistency of the magnitude and direction of the chemical shifts within the database, and the chemical shift correlation of the unknown protein with the database. ORBplus visualizes the results by a histogram and a vector diagram, and provides residue specific predictions on structural similarities with the database. The second method we used was partial least squares (PLS), which is a multivariate statistical technique used to correlate response and predictor variables. We investigated the ability of these methods to predict the tertiary structure of the contractile regulatory protein troponin C. Troponin C undergoes a closed-to-open conformational change, which is coupled to its function in muscle. We found that both ORBplus and PLS were able to identify patterns in the 1 H, 15 N-HSQC NMR data from different states of troponin C that correlated to its conformation.

  3. Beyond triage: the diagnostic accuracy of emergency department nursing staff risk assessment in patients with suspected acute coronary syndromes.

    Science.gov (United States)

    Carlton, Edward Watts; Khattab, Ahmed; Greaves, Kim

    2016-02-01

    To establish the accuracy of emergency department (ED) nursing staff risk assessment using an established chest pain risk score alone and when incorporated with presentation high-sensitivity troponin testing as part of an accelerated diagnostic protocol (ADP). Prospective observational study comparing nursing and physician risk assessment using the modified Goldman (m-Goldman) score and a predefined ADP, incorporating presentation high-sensitivity troponin. A UK District ED. Consecutive patients, aged ≥18, with suspected cardiac chest pain and non-ischaemic ECG, for whom the treating physician determined serial troponin testing was required. 30-day major adverse cardiac events (MACE). 960 participants were recruited. 912/960 (95.0%) had m-Goldman scores recorded by physicians and 745/960 (77.6%) by nursing staff. The area under the curve of the m-Goldman score in predicting 30-day MACE was 0.647 (95% CI 0.594 to 0.700) for physicians and 0.572 (95% CI 0.510 to 0.634) for nursing staff (p=0.09). When incorporated into an ADP, sensitivity for the rule-out of MACE was 99.2% (95% CI 94.8% to 100%) and 96.7% (90.3% to 99.2%) for physicians and nurses, respectively. One patient in the physician group (0.3%) and three patients (1.1%) in the nursing group were classified as low risk yet had MACE. There was fair agreement in the identification of low-risk patients (kappa 0.31, 95% CI 0.24 to 0.38). The diagnostic accuracy of ED nursing staff risk assessment is similar to that of ED physicians and interobserver reliability between assessor groups is fair. When incorporating high-sensitivity troponin testing, a nurse-led ADP has a miss rate of 1.1% for MACE at 30 days. Controlled Trials Database (ISRCTN no. 21109279). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. Cardiac Troponin Elevation Predicts Mortality in Patients Undergoing Orthotopic Liver Transplantation

    Directory of Open Access Journals (Sweden)

    David Snipelisky

    2013-01-01

    Full Text Available Introduction. While patients undergoing orthotopic liver transplantation (OLT have high cardiovascular event rates, preoperative risk stratification may not necessarily predict those susceptible patients. Troponin T (TnT may help predict patients at risk for cardiovascular complications. Methods. Consecutive patients undergoing OLT at Mayo Clinic in Florida between 1998 and 2010 who had TnT obtained within 10 days following surgery were included. Three groups were compared based on TnT level: (1 normal (TnT ≤0.01 ng/mL, (2 intermediate (TnT 0.02–0.11 ng/mL, and (3 elevated (TnT >0.11 ng/mL. Overall and cardiovascular mortality was assessed. Results. Of the 78 patients included, there was no difference in age, gender, severity of liver disease, and echocardiographic findings. Patients in the normal and intermediate TnT groups had a lower overall mortality rate (14.3% and 0%, resp. when compared with those with elevated TnT (50%; P=0.001. Patients in the elevated TnT group had a cardiovascular mortality rate of 37.5% compared with 1.4% in the other groups combined (P<0.01. The elevated TnT group had a much higher mortality rate when compared with those in the intermediate group (P<0.0001. Conclusion. TnT may accurately help risk stratify patients in the early postoperative setting to better predict cardiovascular complications.

  5. Laser-engraved carbon nanotube paper for instilling high sensitivity, high stretchability, and high linearity in strain sensors

    KAUST Repository

    Xin, Yangyang

    2017-06-29

    There is an increasing demand for strain sensors with high sensitivity and high stretchability for new applications such as robotics or wearable electronics. However, for the available technologies, the sensitivity of the sensors varies widely. These sensors are also highly nonlinear, making reliable measurement challenging. Here we introduce a new family of sensors composed of a laser-engraved carbon nanotube paper embedded in an elastomer. A roll-to-roll pressing of these sensors activates a pre-defined fragmentation process, which results in a well-controlled, fragmented microstructure. Such sensors are reproducible and durable and can attain ultrahigh sensitivity and high stretchability (with a gauge factor of over 4.2 × 10(4) at 150% strain). Moreover, they can attain high linearity from 0% to 15% and from 22% to 150% strain. They are good candidates for stretchable electronic applications that require high sensitivity and linearity at large strains.

  6. Novel Risk Stratification Assays for Acute Coronary Syndrome.

    Science.gov (United States)

    Ahmed, Haitham M; Hazen, Stanley L

    2017-08-01

    Since identification of aspartate aminotransferase as the first cardiac biomarker in the 1950s, there have been a number of new markers used for myocardial damage detection over the decades. There have also been several generations of troponin assays, each with progressively increasing sensitivity for troponin detection. Accordingly, the "standard of care" for myocardial damage detection continues to change. The purpose of this paper is to review the clinical utility, biological mechanisms, and predictive value of these various biomarkers in contemporary clinical studies. As of this writing, a fifth "next" generation troponin assay has now been cleared by the US Food and Drug Administration for clinical use in the USA for subjects presenting with suspected acute coronary syndromes. Use of these high-sensitivity assays has allowed for earlier detection of myocardial damage as well as greater negative predictive value for infarction after only one or two serial measurements. Recent algorithms utilizing these assays have allowed for more rapid rule-out of myocardial infarction in emergency department settings. In this review, we discuss novel assays available for the risk assessment of subjects presenting with chest pain, including both the "next generation" cardiac troponin assays as well as other novel biomarkers. We review the biological mechanisms for these markers, and explore the positive and negative predictive value of the assays in clinical studies, where reported. We also discuss the potential use of these new markers within the context of future clinical care in the modern era of higher sensitivity troponin testing. Finally, we discuss advances in new platforms (e.g., mass spectrometry) that historically have not been considered for rapid in vitro diagnostic capabilities, but that are taking a larger role in clinical diagnostics, and whose prognostic value and power promise to usher in new markers with potential for future clinical utility in acute coronary

  7. Highly sensitive detection using microring resonator and nanopores

    Science.gov (United States)

    Bougot-Robin, K.; Hoste, J. W.; Le Thomas, N.; Bienstman, P.; Edel, J. B.

    2016-04-01

    One of the most significant challenges facing physical and biological scientists is the accurate detection and identification of single molecules in free-solution environments. The ability to perform such sensitive and selective measurements opens new avenues for a large number of applications in biological, medical and chemical analysis, where small sample volumes and low analyte concentrations are the norm. Access to information at the single or few molecules scale is rendered possible by a fine combination of recent advances in technologies. We propose a novel detection method that combines highly sensitive label-free resonant sensing obtained with high-Q microcavities and position control in nanoscale pores (nanopores). In addition to be label-free and highly sensitive, our technique is immobilization free and does not rely on surface biochemistry to bind probes on a chip. This is a significant advantage, both in term of biology uncertainties and fewer biological preparation steps. Through combination of high-Q photonic structures with translocation through nanopore at the end of a pipette, or through a solid-state membrane, we believe significant advances can be achieved in the field of biosensing. Silicon microrings are highly advantageous in term of sensitivity, multiplexing, and microfabrication and are chosen for this study. In term of nanopores, we both consider nanopore at the end of a nanopipette, with the pore being approach from the pipette with nanoprecise mechanical control. Alternatively, solid state nanopores can be fabricated through a membrane, supporting the ring. Both configuration are discussed in this paper, in term of implementation and sensitivity.

  8. Chronic defensiveness and neuroendocrine dysfunction reflect a novel cardiac troponin T cut point: The SABPA study.

    Science.gov (United States)

    Malan, Leoné; Hamer, Mark; von Känel, Roland; Lambert, Gavin W; Delport, Rhena; Steyn, Hendrik S; Malan, Nicolaas T

    2017-11-01

    Sympatho-adrenal responses are activated as an innate defense coping (DefS) mechanism during emotional stress. Whether these sympatho-adrenal responses drive cardiac troponin T (cTnT) increases are unknown. Therefore, associations between cTnT and sympatho-adrenal responses were assessed. A prospective bi-ethnic cohort, excluding atrial fibrillation, myocardial infarction and stroke cases, was followed for 3 years (N=342; 45.6±9.0years). We obtained serum high-sensitive cTnT and exposure measures [Coping-Strategy-Indicator, depression/Patient-Health-Questionnarie-9, 24h BP, 24h heart-rate-variability (HRV) and 24h urinary catecholamines]. Blacks showed moderate depression (45% vs. 16%) and 24h hypertension (67% vs. 42%) prevalence compared to Whites. A receiver-operating-characteristics cTnT cut-point 4.2ng/L predicting hypertension in Blacks was used as binary outcome measure in relation to exposure measures [AUC 0.68 (95% CI 0.60-0.76); sensitivity/specificity 63/70%; P≤0.001]. Bi-ethnic cTnT-incidence was similar (Blacks=27%, Whites=25%) with cTnT-recovery better in Blacks (9%) compared to Whites (5%), P=0.001. In cross-sectional analyses, elevated cTnT was related to DefS [OR 1.08 (95% CI 0.99-1.16); P=0.06]; 24h BP [OR 1.03-1.04 (95% CI 1.01-1.08); P≤0.02] and depressed HRV [OR 2.19 (95% CI 1.09-4.41); P=0.03] in Blacks, but not in Whites. At 3year follow-up, elevated cTnT was related to attenuated urine norepinephrine:creatinine ratio in Blacks [OR 1.46 (95% CI 1.01-2.10); P=0.04]. In Whites, a cut point of 5.6ng/L cTnT predicting hypertension was not associated with exposure measures. Central neural control systems exemplified a brain-heart stress pathway. Desensitization of sympatho-adrenal responses occurred with initial neural- (HRV) followed by neuroendocrine dysfunction (norepinephrine:creatinine) in relation to elevated cTnT. Chronic defensiveness may thus drive the desensitization or physiological depression, reflecting ischemic heart disease

  9. Development of High Temperature/High Sensitivity Novel Chemical Resistive Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Chunrui [Univ. of Texas, San Antonio, TX (United States); Enriquez, Erik [Univ. of Texas, San Antonio, TX (United States); Wang, Haibing [Univ. of Texas, San Antonio, TX (United States); Xu, Xing [Univ. of Texas, San Antonio, TX (United States); Bao, Shangyong [Univ. of Texas, San Antonio, TX (United States); Collins, Gregory [Univ. of Texas, San Antonio, TX (United States)

    2013-08-13

    The research has been focused to design, fabricate, and develop high temperature/high sensitivity novel multifunctional chemical sensors for the selective detection of fossil energy gases used in power and fuel systems. By systematically studying the physical properties of the LnBaCo2O5+d (LBCO) [Ln=Pr or La] thin-films, a new concept chemical sensor based high temperature chemical resistant change has been developed for the application for the next generation highly efficient and near zero emission power generation technologies. We also discovered that the superfast chemical dynamic behavior and an ultrafast surface exchange kinetics in the highly epitaxial LBCO thin films. Furthermore, our research indicates that hydrogen can superfast diffuse in the ordered oxygen vacancy structures in the highly epitaxial LBCO thin films, which suggest that the LBCO thin film not only can be an excellent candidate for the fabrication of high temperature ultra sensitive chemical sensors and control systems for power and fuel monitoring systems, but also can be an excellent candidate for the low temperature solid oxide fuel cell anode and cathode materials.

  10. Nanocomposites of gold nanoparticles and graphene oxide towards an stable label-free electrochemical immunosensor for detection of cardiac marker troponin-I

    International Nuclear Information System (INIS)

    Liu, Guozhen; Qi, Meng; Zhang, Yin; Cao, Chaomin; Goldys, Ewa M.

    2016-01-01

    A stable label-free amperometric immunosensor is presented based on gold nanoparticles and graphene oxide nanocomposites for detection of cardiac troponin-I in the early diagnosis of myocardial infarction. For designing of the sensing platform, firstly the nanocomposites based on GO and AuNPs were prepared and anchored on electrode surfaces. The formed nanocomposites provided a platform with big surface area for loading anti-cTnI capture antibody, and worked as a bridge for fast electron transfer subsequently increased the sensitivity. Moreover, the linkages between AuNP, GO, and electrodes were based on covalent bonding by aryldiazonium salt coupling chemistry, which favors the stability of the sensing interface. Finally, the anti-cTnI detection antibody was immobilized on GO tailored with ferrocene molecules, functioning as the signal reporter for the detection of cTnI. The modification process was monitored using electrochemistry, SEM, XPS. The herein immunosensor demonstrates a good selectivity and high sensitivity against human-cTnI, and is capable of detecting cTnI at concentrations as low as 0.05 ng mL −1 , which is 100 times lower than that possible by conventional methods. It is potential to design the portable sensing platform based on AuNPs and GO nanocomposites for future point-of-care diagnostics. - Highlights: • Nanocomposites based on GO and AuNPs were prepared and anchored on the electrode surfaces covalently to form a stable sensing interface. • The anti-cTnI detection antibody was immobilized on GO tailored with ferrocene molecules, functioning as the signal reporter for the detection of cTnI. • The detectable concentration of cTnI is 0.05 ng mL -1 in buffer with the assay time of less than 5 min. • The herein simple and novel approach for fabrication of AuNP and graphene based platform is promising for future fabrication of point-of-care devices.

  11. Pharmacodynamic modeling of cardiac biomarkers in breast cancer patients treated with anthracycline and trastuzumab regimens

    NARCIS (Netherlands)

    de Vries Schultink, Aurelia H M; Boekhout, Annelies H; Gietema, Jourik A; Burylo, Artur M; Dorlo, Thomas P C; van Hasselt, J G Coen; Schellens, Jan H M; Huitema, Alwin D R

    Trastuzumab is associated with cardiotoxicity, manifesting as a decrease of the left-ventricular ejection fraction (LVEF). Administration of anthracyclines prior to trastuzumab increases risk of cardiotoxicity. High-sensitive troponin T and N-terminal-pro-brain natriuretic peptide (NT-proBNP) are

  12. Replacement of Cetyltrimethylammoniumbromide Bilayer on Gold Nanorod by Alkanethiol Crosslinker for Enhanced Plasmon Resonance Sensitivity

    Science.gov (United States)

    Casas, Justin; Venkataramasubramani, Meenakshi; Wang, Yanyan; Tang, Liang

    2013-01-01

    Surface modification of gold nanorods (GNRs) is often problematic due to tightly packed cetyltrimethylammoniumbromide (CTAB) bilayer. Herein, we performed a double phase transfer ligand exchange to achieve displacement of CTAB on nanorods. During the removal, 11-mercaptoundecanoic acid (MUDA) crosslinker is simultaneously assembled on nanorod surfaces to prevent aggregation. The resulting MUDA-GNRs retain the shape and position of plasmon peaks similar to CTAB-capped GNRs. The introduction of carboxyl groups allows covalent conjugation of biological receptors in a facile fashion to construct a robust, label-free biosensor based on localized surface plasmon resonance (LSPR) transduction of biomolecular interaction. More importantly, smaller MUDA layer on the GNRs reduces the distance of target binding to the plasmonic nanostructure interface, leading to a significant enhancement in LSPR assay sensitivity and specificity. Compared to modification using conventional electropolymer adsorption, MUDA-coated gold nanosensor exhibits five times lower detection limit for cardiac troponin I assay with a high selectivity. PMID:23816849

  13. Importância da troponina I no diagnóstico do infarto do miocárdio no pós-operatório de cirurgia de revascularização The importance of troponin I in the diagnosis of myocardial infarction in the postoperative of coronary artery bypass graft surgery

    Directory of Open Access Journals (Sweden)

    Marcos Aurélio Barboza de Oliveira

    2009-03-01

    second postoperative day with myocardial infarction (P=0.0005. ROC curve was used to define the cutoff value, and 6.1 ng/ml (sensitivity=90.0%, specificity=82.1%, OR=49.8 with CI=95% 6.1- 410.4, P<0.0001 were found. CONCLUSION: The chance of a patient with postoperative myocardial infarction to present troponin I equal to or higher than 6.1 ng/ml is 49.8-fold higher than the chance of a patient without infarction to present troponin I higher than this value.

  14. Myofibrillar troponin exists in three states and there is signal transduction along skeletal myofibrillar thin filaments.

    Science.gov (United States)

    Swartz, Darl R; Yang, Zhenyun; Sen, Asok; Tikunova, Svetlana B; Davis, Jonathan P

    2006-08-18

    Activation of striated muscle contraction is a highly cooperative signal transduction process converting calcium binding by troponin C (TnC) into interactions between thin and thick filaments. Once calcium is bound, transduction involves changes in protein interactions along the thin filament. The process is thought to involve three different states of actin-tropomyosin (Tm) resulting from changes in troponin's (Tn) interaction with actin-Tm: a blocked (B) state preventing myosin interaction, a closed (C) state allowing weak myosin interactions and favored by calcium binding to Tn, and an open or M state allowing strong myosin interactions. This was tested by measuring the apparent rate of Tn dissociation from rigor skeletal myofibrils using labeled Tn exchange. The location and rate of exchange of Tn or its subunits were measured by high-resolution fluorescence microscopy and image analysis. Three different rates of Tn exchange were observed that were dependent on calcium concentration and strong cross-bridge binding that strongly support the three-state model. The rate of Tn dissociation in the non-overlap region was 200-fold faster at pCa 4 (C-state region) than at pCa 9 (B-state region). When Tn contained engineered TnC mutants with weakened regulatory TnI interactions, the apparent exchange rate at pCa 4 in the non-overlap region increased proportionately with TnI-TnC regulatory affinity. This suggests that the mechanism of calcium enhancement of the rate of Tn dissociation is by favoring a TnI-TnC interaction over a TnI-actin-Tm interaction. At pCa 9, the rate of Tn dissociation in the overlap region (M-state region) was 100-fold faster than the non-overlap region (B-state region) suggesting that strong cross-bridges increase the rate of Tn dissociation. At pCa 4, the rate of Tn dissociation was twofold faster in the non-overlap region (C-state region) than the overlap region (M-state region) that likely involved a strong cross-bridge influence on Tn

  15. Impact of copeptin on diagnosis of acute coronary syndrome

    African Journals Online (AJOL)

    Zeinab H. El Sayed

    2014-03-17

    Mar 17, 2014 ... the levels of copeptin, high-sensitivity cardiac troponin high ... The Egyptian Journal of Medical Human Genetics ... negative predictive value, which aids in early and safe ruling out of ... a standardized protocol in the National Heart Institute, Health ... Local ethics committee approved the study proto- col and ...

  16. Cardiovascular biomarkers and sex: the case for women.

    Science.gov (United States)

    Daniels, Lori B; Maisel, Alan S

    2015-10-01

    Measurement of biomarkers is a critical component of cardiovascular care. Women and men differ in their cardiac physiology and manifestations of cardiovascular disease. Although most cardiovascular biomarkers are used by clinicians without taking sex into account, sex-specific differences in biomarkers clearly exist. Baseline concentrations of many biomarkers (including cardiac troponin, natriuretic peptides, galectin-3, and soluble ST2) differ in men versus women, but these sex-specific differences do not generally translate into a need for differential sex-based cut-off points. Furthermore, most biomarkers are similarly diagnostic and prognostic, regardless of sex. Two potential exceptions are cardiac troponins measured by high-sensitivity assay, and proneurotensin. Troponin levels are lower in women than in men and, with the use of high-sensitivity assays, sex-specific cut-off points might improve the diagnosis of myocardial infarction. Proneurotensin is a novel biomarker that was found to be predictive of incident cardiovascular disease in women, but not men, and was also predictive of incident breast cancer. If confirmed, proneurotensin might be a unique biomarker of disease risk in women. With any biomarker, an understanding of sex-specific differences might improve its use and might also lead to an enhanced understanding of the physiological differences between the hearts of men and women.

  17. High-field modulated ion-selective field-effect-transistor (FET) sensors with sensitivity higher than the ideal Nernst sensitivity.

    Science.gov (United States)

    Chen, Yi-Ting; Sarangadharan, Indu; Sukesan, Revathi; Hseih, Ching-Yen; Lee, Geng-Yen; Chyi, Jen-Inn; Wang, Yu-Lin

    2018-05-29

    Lead ion selective membrane (Pb-ISM) coated AlGaN/GaN high electron mobility transistors (HEMT) was used to demonstrate a whole new methodology for ion-selective FET sensors, which can create ultra-high sensitivity (-36 mV/log [Pb 2+ ]) surpassing the limit of ideal sensitivity (-29.58 mV/log [Pb 2+ ]) in a typical Nernst equation for lead ion. The largely improved sensitivity has tremendously reduced the detection limit (10 -10  M) for several orders of magnitude of lead ion concentration compared to typical ion-selective electrode (ISE) (10 -7  M). The high sensitivity was obtained by creating a strong filed between the gate electrode and the HEMT channel. Systematical investigation was done by measuring different design of the sensor and gate bias, indicating ultra-high sensitivity and ultra-low detection limit obtained only in sufficiently strong field. Theoretical study in the sensitivity consistently agrees with the experimental finding and predicts the maximum and minimum sensitivity. The detection limit of our sensor is comparable to that of Inductively-Coupled-Plasma Mass Spectrum (ICP-MS), which also has detection limit near 10 -10  M.

  18. Silicon nanowire structures as high-sensitive pH-sensors

    International Nuclear Information System (INIS)

    Belostotskaya, S O; Chuyko, O V; Kuznetsov, A E; Kuznetsov, E V; Rybachek, E N

    2012-01-01

    Sensitive elements for pH-sensors created on silicon nanostructures were researched. Silicon nanostructures have been used as ion-sensitive field effect transistor (ISFET) for the measurement of solution pH. Silicon nanostructures have been fabricated by 'top-down' approach and have been studied as pH sensitive elements. Nanowires have the higher sensitivity. It was shown, that sensitive element, which is made of 'one-dimensional' silicon nanostructure have bigger pH-sensitivity as compared with 'two-dimensional' structure. Integrated element formed from two p- and n-type nanowire ISFET ('inverter') can be used as high sensitivity sensor for local relative change [H+] concentration in very small volume.

  19. Development of a highly sensitive lithium fluoride thermoluminescence dosimeter

    International Nuclear Information System (INIS)

    Moraes da Silva, Teresinha de; Campos, Leticia Lucente

    1995-01-01

    In recent times, LiF: Mg, Cu, P thermoluminescent phosphor has been increasingly in use for radiation monitoring due its high sensitivity and ease of preparation. The Dosimetric Materials Production Laboratory of IPEN, (Nuclear Energy Institute) has developed a simple method to obtain high sensitivity LiF. The preparation method is described. (author). 4 refs., 1 fig., 1 tab

  20. Phase sensitive diffraction sensor for high sensitivity refractive index measurement

    Science.gov (United States)

    Kumawat, Nityanand; Varma, Manoj; Kumar, Sunil

    2018-02-01

    In this study a diffraction based sensor has been developed for bio molecular sensing applications and performing assays in real time. A diffraction grating fabricated on a glass substrate produced diffraction patterns both in transmission and reflection when illuminated by a laser diode. We used zeroth order I(0,0) as reference and first order I(0,1) as signal channel and conducted ratiometric measurements that reduced noise by more than 50 times. The ratiometric approach resulted in a very simple instrumentation with very high sensitivity. In the past, we have shown refractive index measurements both for bulk and surface adsorption using the diffractive self-referencing approach. In the current work we extend the same concept to higher diffraction orders. We have considered order I(0,1) and I(1,1) and performed ratiometric measurements I(0,1)/I(1,1) to eliminate the common mode fluctuations. Since orders I(0,1) and I(1,1) behaved opposite to each other, the resulting ratio signal amplitude increased more than twice compared to our previous results. As a proof of concept we used different salt concentrations in DI water. Increased signal amplitude and improved fluid injection system resulted in more than 4 times improvement in detection limit, giving limit of detection 1.3×10-7 refractive index unit (RIU) compared to our previous results. The improved refractive index sensitivity will help significantly for high sensitivity label free bio sensing application in a very cost-effective and simple experimental set-up.

  1. Heterogeneous catalysis in highly sensitive microreactors

    DEFF Research Database (Denmark)

    Olsen, Jakob Lind

    This thesis present a highly sensitive silicon microreactor and examples of its use in studying catalysis. The experimental setup built for gas handling and temperature control for the microreactor is described. The implementation of LabVIEW interfacing for all the experimental parts makes...

  2. The selectively bred high alcohol sensitivity (HAS) and low alcohol sensitivity (LAS) rats differ in sensitivity to nicotine.

    Science.gov (United States)

    de Fiebre, NancyEllen C; Dawson, Ralph; de Fiebre, Christopher M

    2002-06-01

    Studies in rodents selectively bred to differ in alcohol sensitivity have suggested that nicotine and ethanol sensitivities may cosegregate during selective breeding. This suggests that ethanol and nicotine sensitivities may in part be genetically correlated. Male and female high alcohol sensitivity (HAS), control alcohol sensitivity, and low alcohol sensitivity (LAS) rats were tested for nicotine-induced alterations in locomotor activity, body temperature, and seizure activity. Plasma and brain levels of nicotine and its primary metabolite, cotinine, were measured in these animals, as was the binding of [3H]cytisine, [3H]epibatidine, and [125I]alpha-bungarotoxin in eight brain regions. Both replicate HAS lines were more sensitive to nicotine-induced locomotor activity depression than the replicate LAS lines. No consistent HAS/LAS differences were seen on other measures of nicotine sensitivity; however, females were more susceptible to nicotine-induced seizures than males. No HAS/LAS differences in nicotine or cotinine levels were seen, nor were differences seen in the binding of nicotinic ligands. Females had higher levels of plasma cotinine and brain nicotine than males but had lower brain cotinine levels than males. Sensitivity to a specific action of nicotine cosegregates during selective breeding for differential sensitivity to a specific action of ethanol. The differential sensitivity of the HAS/LAS rats is due to differences in central nervous system sensitivity and not to pharmacokinetic differences. The differential central nervous system sensitivity cannot be explained by differences in the numbers of nicotinic receptors labeled in ligand-binding experiments. The apparent genetic correlation between ethanol and nicotine sensitivities suggests that common genes modulate, in part, the actions of both ethanol and nicotine and may explain the frequent coabuse of these agents.

  3. A high sensitivity nanomaterial based SAW humidity sensor

    Energy Technology Data Exchange (ETDEWEB)

    Wu, T-T; Chou, T-H [Institute of Applied Mechanics, National Taiwan University, Taipei 106, Taiwan (China); Chen, Y-Y [Department of Mechanical Engineering, Tatung University, Taipei 104, Taiwan (China)], E-mail: wutt@ndt.iam.ntu.edu.tw

    2008-04-21

    In this paper, a highly sensitive humidity sensor is reported. The humidity sensor is configured by a 128{sup 0}YX-LiNbO{sub 3} based surface acoustic wave (SAW) resonator whose operating frequency is at 145 MHz. A dual delay line configuration is realized to eliminate external temperature fluctuations. Moreover, for nanostructured materials possessing high surface-to-volume ratio, large penetration depth and fast charge diffusion rate, camphor sulfonic acid doped polyaniline (PANI) nanofibres are synthesized by the interfacial polymerization method and further deposited on the SAW resonator as selective coating to enhance sensitivity. The humidity sensor is used to measure various relative humidities in the range 5-90% at room temperature. Results show that the PANI nanofibre based SAW humidity sensor exhibits excellent sensitivity and short-term repeatability.

  4. Highly sensitive microcalorimeters for radiation research

    International Nuclear Information System (INIS)

    Avaev, V.N.; Demchuk, B.N.; Ioffe, L.A.; Efimov, E.P.

    1984-01-01

    Calorimetry is used in research at various types of nuclear-physics installations to obtain information on the quantitative and qualitative composition of ionizing radiation in a reactor core and in the surrounding layers of the biological shield. In this paper, the authors examine the characteristics of highly sensitive microcalorimeters with modular semiconductor heat pickups designed for operation in reactor channels. The microcalorimeters have a thin-walled aluminum housing on whose inner surface modular heat pickups are placed radially as shown here. The results of measurements of the temperature dependence of the sensitivity of the microcalorimeters are shown. The results of measuring the sensitivity of a PMK-2 microcalorimeter assembly as a function of integrated neutron flux for three energy intervals and the adsorbed gamma energy are shown. In order to study specimens with different shapes and sizes, microcalorimeters with chambers in the form of cylinders and a parallelepiped were built and tested

  5. Reversible Stress Cardiomyopathy Presenting as Acute Coronary Syndrome with Elevated Troponin in the Absence of Regional Wall Motion Abnormalities: A Forme Fruste of Stress Cardiomyopathy?

    Directory of Open Access Journals (Sweden)

    Mahesh Anantha Narayanan

    2014-01-01

    Full Text Available We present a case of reversible stress cardiomyopathy in a surgical patient, described here as a forme fruste due to its atypical features. It is important to recognize such unusual presentation of stress cardiomyopathy that mimics acute coronary syndrome. Stress cardiomyopathy commonly presents as acute coronary syndrome and is characterized by typical or atypical variants of regional wall motion abnormalities. We report a 60-year-old Caucasian male with reversible stress cardiomyopathy following a sternal fracture fixation. Although the patient had several typical features of stress cardiomyopathy including physical stress, ST-segment elevation, elevated cardiac biomarkers and normal epicardial coronaries, there were few features that were atypical, including unusual age, gender, absence of regional wall motion abnormalities, high lateral ST elevation, and high troponin-ejection fraction product. In conclusion, this could represent a forme fruste of stress cardiomyopathy.

  6. The value of determination of blood cardiac troponin T, IL-8 and TNF-α contents for the diagnosis and prognosis assessment in patients with viral myocarditis

    International Nuclear Information System (INIS)

    Tao Qian; Zhou Xuanyan; Li Enjie

    2006-01-01

    Objective: To investigate the value of determination of blood cardiac troponin T (cTnT), IL-8 and TNF-α contents for the diagnosis and prognosis assessment in patients with viral myocarditis (VMC). Methods: Plasma cTnT (with immuno-infiltration method) and serum IL - 8, TNF ( with ELISA) contents were measured in 86 patients with VMC at different stages ( 1 months, 6 months), and 30 controls. Results: The positive rates of blood cTnT, IL-8 and TNF-α in acute VMC patients were significantly higher than those in patients with history less than 6 months as well as with history more than 6 months and the controls group (P 0.05). The cure rate in patients with positive cTnT was significantly lower than that in patients with negative cTnT both at 1 months and 6 months (P<0.005). Conclusion: Blood cTnT, IL-8 and TNF-α are sensitive and specific predictors for diagnosis and prognosis assessment in patients with VMC. (authors)

  7. Genotype‐specific pathogenic effects in human dilated cardiomyopathy

    Science.gov (United States)

    Schuldt, Maike; Harakalova, Magdalena; Vink, Aryan; Asselbergs, Folkert W.; Pinto, Jose R.; Krüger, Martina; Kuster, Diederik W. D.; van der Velden, Jolanda

    2017-01-01

    Key points Mutations in genes encoding cardiac troponin I (TNNI3) and cardiac troponin T (TNNT2) caused altered troponin protein stoichiometry in patients with dilated cardiomyopathy. TNNI3p.98trunc resulted in haploinsufficiency, increased Ca2+‐sensitivity and reduced length‐dependent activation. TNNT2p.K217del caused increased passive tension.A mutation in the gene encoding Lamin A/C (LMNA p.R331Q) led to reduced maximal force development through secondary disease remodelling in patients suffering from dilated cardiomyopathy.Our study shows that different gene mutations induce dilated cardiomyopathy via diverse cellular pathways. Abstract Dilated cardiomyopathy (DCM) can be caused by mutations in sarcomeric and non‐sarcomeric genes. In this study we defined the pathogenic effects of three DCM‐causing mutations: the sarcomeric mutations in genes encoding cardiac troponin I (TNNI3p.98truncation) and cardiac troponin T (TNNT2p.K217deletion; also known as the p.K210del) and the non‐sarcomeric gene mutation encoding lamin A/C (LMNAp.R331Q). We assessed sarcomeric protein expression and phosphorylation and contractile behaviour in single membrane‐permeabilized cardiomyocytes in human left ventricular heart tissue. Exchange with recombinant troponin complex was used to establish the direct pathogenic effects of the mutations in TNNI3 and TNNT2. The TNNI3p.98trunc and TNNT2p.K217del mutation showed reduced expression of troponin I to 39% and 51%, troponin T to 64% and 53%, and troponin C to 73% and 97% of controls, respectively, and altered stoichiometry between the three cardiac troponin subunits. The TNNI3p.98trunc showed pure haploinsufficiency, increased Ca2+‐sensitivity and impaired length‐dependent activation. The TNNT2p.K217del mutation showed a significant increase in passive tension that was not due to changes in titin isoform composition or phosphorylation. Exchange with wild‐type troponin complex corrected troponin protein levels to 83% of

  8. Troponin T, N-terminal pro natriuretic peptide and a patent ductus arteriosus scoring system predict death before discharge or neurodevelopmental outcome at 2 years in preterm infants.

    LENUS (Irish Health Repository)

    El-Khuffash, Afif F

    2011-03-01

    There is little consensus regarding the use of echocardiography in patent ductus arteriosus (PDA) treatment in preterm infants. The use of troponin T (cTnT) and N-terminal Pro-BNP (NTpBNP) in combination with echocardiography assessment may facilitate the development of a superior predictive model.

  9. Lack of concordance between a rapid bedside and conventional laboratory method of cardiac troponin testing: impact on risk stratification of patients suspected of acute coronary syndrome.

    NARCIS (Netherlands)

    Cramer, G.E.; Kievit, P.C.; Brouwer, M.A.; Keijzer, M.H. de; Luijten, H.E.; Verheugt, F.W.A.

    2007-01-01

    OBJECTIVES: This study was designed to test the usefulness of a bedside assay as compared to a laboratory method of troponin testing to predict adverse cardiac outcome of chest pain patients. METHODS: We studied 358 ER visits of patients suspected of a non ST-elevation acute coronary syndrome. cTnI

  10. Low Power and High Sensitivity MOSFET-Based Pressure Sensor

    International Nuclear Information System (INIS)

    Zhang Zhao-Hua; Ren Tian-Ling; Zhang Yan-Hong; Han Rui-Rui; Liu Li-Tian

    2012-01-01

    Based on the metal-oxide-semiconductor field effect transistor (MOSFET) stress sensitive phenomenon, a low power MOSFET pressure sensor is proposed. Compared with the traditional piezoresistive pressure sensor, the present pressure sensor displays high performances on sensitivity and power consumption. The sensitivity of the MOSFET sensor is raised by 87%, meanwhile the power consumption is decreased by 20%. (cross-disciplinary physics and related areas of science and technology)

  11. Troponin T elevation after permanent pacemaker implantation.

    Science.gov (United States)

    Chen, Xueying; Yu, Ziqing; Bai, Jin; Hu, Shulan; Wang, Wei; Qin, Shengmei; Wang, Jingfeng; Sun, Zhe; Su, Yangang; Ge, Junbo

    2017-08-01

    The objective of the study is to study the incidence, significance, and factors associated with cardiac troponin T (CTNT) elevation after pacemaker implantation. Three hundred seventy-four patients (104 single-chamber pacemakers or ICD, 243 dual-chamber pacemakers, and 27 cardiac resynchronization therapy/cardiac resynchronization therapy defibrillator) who had normal levels of CTNT at baseline and underwent implantation of a permanent pacemaker system were included in this study. Serum levels of CTNT were measured at baseline, 6 and 24 h after the implantation procedure. The median of CTNT levels increased from 0.012 ng/mL at baseline to 0.032 and 0.019 ng/mL at 6 and 24 h after the procedure, respectively (all p 0.09 ng/mL). After 1-year follow-up, the incidence of complications including dislodgement of the lead, pocket infection, pneumothorax, hemothorax, and vein thrombus and cardiac outcomes including hospitalization of heart failure, coronary artery disease, arrhythmia, and cardiovascular mortality was not significantly different between the normal and elevated CTNT groups at 6 h after the procedure. By logistic regression analysis, gender, N-terminal pro-B type natriuretic peptide (NT-pro-BNP) at baseline, left ventricular ejection fractions (LVEF), estimated glomerular filtration rate (eGFR), and fluoroscopy time were independently associated with CTNT elevation after adjusted for age, pacemaker types, right ventricle lead location (RVA or RVOT), heart function, and left ventricular end systolic dimension. Pacemaker implantation was found to be accompanied with CTNT elevation in 55.6% of the patients at 6 h after the procedure, and its kinetics were fast, which might not be related to the complications and adverse cardiac outcomes within 1 year of follow-up. Moreover, gender, NT-pro-BNP at baseline, LVEF, eGFR, and fluoroscopy time were found to be independent predictors of CTNT elevation.

  12. Single photon detector with high polarization sensitivity.

    Science.gov (United States)

    Guo, Qi; Li, Hao; You, LiXing; Zhang, WeiJun; Zhang, Lu; Wang, Zhen; Xie, XiaoMing; Qi, Ming

    2015-04-15

    Polarization is one of the key parameters of light. Most optical detectors are intensity detectors that are insensitive to the polarization of light. A superconducting nanowire single photon detector (SNSPD) is naturally sensitive to polarization due to its nanowire structure. Previous studies focused on producing a polarization-insensitive SNSPD. In this study, by adjusting the width and pitch of the nanowire, we systematically investigate the preparation of an SNSPD with high polarization sensitivity. Subsequently, an SNSPD with a system detection efficiency of 12% and a polarization extinction ratio of 22 was successfully prepared.

  13. NK sensitivity of neuroblastoma cells determined by a highly sensitive coupled luminescent method

    International Nuclear Information System (INIS)

    Ogbomo, Henry; Hahn, Anke; Geiler, Janina; Michaelis, Martin; Doerr, Hans Wilhelm; Cinatl, Jindrich

    2006-01-01

    The measurement of natural killer (NK) cells toxicity against tumor or virus-infected cells especially in cases with small blood samples requires highly sensitive methods. Here, a coupled luminescent method (CLM) based on glyceraldehyde-3-phosphate dehydrogenase release from injured target cells was used to evaluate the cytotoxicity of interleukin-2 activated NK cells against neuroblastoma cell lines. In contrast to most other methods, CLM does not require the pretreatment of target cells with labeling substances which could be toxic or radioactive. The effective killing of tumor cells was achieved by low effector/target ratios ranging from 0.5:1 to 4:1. CLM provides highly sensitive, safe, and fast procedure for measurement of NK cell activity with small blood samples such as those obtained from pediatric patients

  14. High-sensitivity cardiac troponin T is associated with cognitive decline in older adults at high cardiovascular risk

    DEFF Research Database (Denmark)

    Wijsman, Liselotte W; de Craen, Anton JM; Trompet, Stella

    2016-01-01

    (mean baseline score (standard error (SE)) lowest vs highest third 65.91 (1.16) vs 69.40 (1.10) seconds, p vs 22.40 (0.31) digits coded, p Picture-Word Learning test (9.45 (0.09) vs 9.31 (0.08) pictures remembered, p = 0.......002) and delayed Picture-Word Learning test (10.33 (0.12) vs 10.10 (0.12) pictures remembered, p = 0.013). Furthermore, participants with higher hs-cTnT had steeper decline on Stroop test (mean annual change (SE) lowest vs highest third 0.34 (0.12) vs 1.06 (0.12) seconds, p = 0.013), Letter-Digit Coding test (-0.......29 (0.03) vs -0.46 (0.03) digits coded, p Picture-Word Learning test (0.01 (0.01) vs -0.06 (0.01) pictures remembered, p Picture-Word Learning test (-0.03 (0.01) vs -0.12 (0.02) pictures remembered, p = 0.001). Associations were independent of cardiovascular...

  15. Performance of terahertz metamaterials as high-sensitivity sensor

    Science.gov (United States)

    He, Yanan; Zhang, Bo; Shen, Jingling

    2017-09-01

    A high-sensitivity sensor based on the resonant transmission characteristics of terahertz (THz) metamaterials was investigated, with the proposal and fabrication of rectangular bar arrays of THz metamaterials exhibiting a period of 180 μm on a 25 μm thick flexible polyimide. Varying the size of the metamaterial structure revealed that the length of the rectangular unit modulated the resonant frequency, which was verified by both experiment and simulation. The sensing characteristics upon varying the surrounding media in the sample were tested by simulation and experiment. Changing the surrounding medium from that of air to that of alcohol or oil produced resonant frequency redshifts of 80 GHz or 150 GHz, respectively, which indicates that the sensor possessed a high sensitivity of 667 GHz per unit of refractive index. Finally, the influence of the sample substrate thickness on the sensor sensitivity was investigated by simulation. It may be a reference for future sensor design.

  16. The R21C Mutation in Cardiac Troponin I Imposes Differences in Contractile Force Generation between the Left and Right Ventricles of Knock-In Mice

    Directory of Open Access Journals (Sweden)

    Jingsheng Liang

    2015-01-01

    Full Text Available We investigated the effect of the hypertrophic cardiomyopathy-linked R21C (arginine to cysteine mutation in human cardiac troponin I (cTnI on the contractile properties and myofilament protein phosphorylation in papillary muscle preparations from left (LV and right (RV ventricles of homozygous R21C+/+ knock-in mice. The maximal steady-state force was significantly reduced in skinned papillary muscle strips from the LV compared to RV, with the latter displaying the level of force observed in LV or RV from wild-type (WT mice. There were no differences in the Ca2+ sensitivity between the RV and LV of R21C+/+ mice; however, the Ca2+ sensitivity of force was higher in RV-R21C+/+ compared with RV-WT and lower in LV- R21C+/+ compared with LV-WT. We also observed partial loss of Ca2+ regulation at low [Ca2+]. In addition, R21C+/+-KI hearts showed no Ser23/24-cTnI phosphorylation compared to LV or RV of WT mice. However, phosphorylation of the myosin regulatory light chain (RLC was significantly higher in the RV versus LV of R21C+/+ mice and versus LV and RV of WT mice. The difference in RLC phosphorylation between the ventricles of R21C+/+ mice likely contributes to observed differences in contractile force and the lower tension monitored in the LV of HCM mice.

  17. Perinatal Changes of Cardiac Troponin-I in Normal and Intrauterine Growth-Restricted Pregnancies

    Directory of Open Access Journals (Sweden)

    Nicoletta Iacovidou

    2007-01-01

    Full Text Available Intrauterine growth restriction (IUGR implies fetal hypoxia, resulting in blood flow redistribution and sparing of vital organs (brain, heart. Serum cardiac Troponin-I (cTnI, a well-established marker of myocardial ischaemia, was measured in 40 mothers prior to delivery, the doubly clamped umbilical cords (representing fetal state, and their 20 IUGR and 20 appropriate-for-gestational-age (AGA neonates on day 1 and 4 postpartum. At all time points, no differences in cTnI levels were observed between the AGA and IUGR groups. Strong positive correlations were documented between maternal and fetal/neonatal values (r≥.498, P≤.025 in all cases in the AGA and r≥.615, P≤.009 in all cases in the IUGR group. These results may indicate (a normal heart function, due to heart sparing, in the IUGR group (b potential crossing of the placental barrier by cTnI in both groups

  18. A High-Sensitivity Current Sensor Utilizing CrNi Wire and Microfiber Coils

    Directory of Open Access Journals (Sweden)

    Xiaodong Xie

    2014-05-01

    Full Text Available We obtain an extremely high current sensitivity by wrapping a section of microfiber on a thin-diameter chromium-nickel wire. Our detected current sensitivity is as high as 220.65 nm/A2 for a structure length of only 35 μm. Such sensitivity is two orders of magnitude higher than the counterparts reported in the literature. Analysis shows that a higher resistivity or/and a thinner diameter of the metal wire may produce higher sensitivity. The effects of varying the structure parameters on sensitivity are discussed. The presented structure has potential for low-current sensing or highly electrically-tunable filtering applications.

  19. An algorithm for rule-in and rule-out of acute myocardial infarction using a novel troponin I assay.

    Science.gov (United States)

    Lindahl, Bertil; Jernberg, Tomas; Badertscher, Patrick; Boeddinghaus, Jasper; Eggers, Kai M; Frick, Mats; Rubini Gimenez, Maria; Linder, Rickard; Ljung, Lina; Martinsson, Arne; Melki, Dina; Nestelberger, Thomas; Rentsch, Katharina; Reichlin, Tobias; Sabti, Zaid; Schubera, Marie; Svensson, Per; Twerenbold, Raphael; Wildi, Karin; Mueller, Christian

    2017-01-15

    To derive and validate a hybrid algorithm for rule-out and rule-in of acute myocardial infarction based on measurements at presentation and after 2 hours with a novel cardiac troponin I (cTnI) assay. The algorithm was derived and validated in two cohorts (605 and 592 patients) from multicentre studies enrolling chest pain patients presenting to the emergency department (ED) with onset of last episode within 12 hours. The index diagnosis and cardiovascular events up to 30 days were adjudicated by independent reviewers. In the validation cohort, 32.6% of the patients were ruled out on ED presentation, 6.1% were ruled in and 61.3% remained undetermined. A further 22% could be ruled out and 9.8% ruled in, after 2 hours. In total, 54.6% of the patients were ruled out with a negative predictive value (NPV) of 99.4% (95% CI 97.8% to 99.9%) and a sensitivity of 97.7% (95% CI 91.9% to 99.7%); 15.8% were ruled in with a positive predictive value (PPV) of 74.5% (95% CI 64.8% to 82.2%) and a specificity of 95.2% (95% CI 93.0% to 96.9%); and 29.6% remained undetermined after 2 hours. No patient in the rule-out group died during the 30-day follow-up in the two cohorts. This novel two-step algorithm based on cTnI measurements enabled just over a third of the patients with acute chest pain to be ruled in or ruled out already at presentation and an additional third after 2 hours. This strategy maximises the speed of rule-out and rule-in while maintaining a high NPV and PPV, respectively. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  20. Nanowire-templated microelectrodes for high-sensitivity pH detection

    DEFF Research Database (Denmark)

    Antohe, V.A.; Radu, Adrian; Mátéfi-Tempfli, Mária

    2009-01-01

    A highly sensitive pH capacitive sensor has been designed by confined growth of vertically aligned nanowire arrays on interdigited microelectrodes. The active surface of the device has been functionalized with an electrochemical pH transducer (polyaniline). We easily tune the device features...... by combining lithographic techniques with electrochemical synthesis. The reported electrical LC resonance measurements show considerable sensitivity enhancement compared to conventional capacitive pH sensors realized with microfabricated interdigited electrodes. The sensitivity can be easily improved...

  1. Clinical and Prognostic Profiles of Cardiomyopathies Caused by Mutations in the Troponin T Gene.

    Science.gov (United States)

    Ripoll-Vera, Tomás; Gámez, José María; Govea, Nancy; Gómez, Yolanda; Núñez, Juana; Socías, Lorenzo; Escandell, Ángela; Rosell, Jorge

    2016-02-01

    Mutations in the troponin T gene (TTNT2) have been associated in small studies with the development of hypertrophic cardiomyopathy characterized by a high risk of sudden death and mild hypertrophy. We describe the clinical course of patients carrying mutations in this gene. We analyzed the clinical characteristics and prognosis of patients with mutations in the TNNT2 gene who were seen in an inherited cardiac disease unit. Of 180 families with genetically studied cardiomyopathies, 21 families (11.7%) were identified as having mutations in TNNT2: 10 families had Arg92Gln, 5 had Arg286His, 3 had Arg278Cys, 1 had Arg92Trp, 1 had Arg94His, and 1 had Ile221Thr. Thirty-three additional genetic carriers were identified through family assessment. The study included 54 genetic carriers: 56% were male, and the mean average age was 41 ± 17 years. There were 33 cases of hypertrophic cardiomyopathy, 9 of dilated cardiomyopathy, and 1 of noncompaction cardiomyopathy, and maximal myocardial thickness was 18.5 ± 6mm. Ventricular dysfunction was present in 30% of individuals and a history of sudden death in 62%. During follow-up, 4 patients died and 14 (33%) received a defibrillator (8 probands, 6 relatives). Mean survival was 54 years. Carriers of Arg92Gln had early disease development, high penetrance, a high risk of sudden death, a high rate of defibrillator implantation, and a high frequency of mixed phenotype. Mutations in the TNNT2 gene were more common in this series than in previous studies. The clinical and prognostic profiles depended on the mutation present. Carriers of the Arg92Gln mutation developed hypertrophic or dilated cardiomyopathy and had a significantly worse prognosis than those with other mutations in TNNT2 or other sarcomeric genes. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  2. Aluminum nanocantilevers for high sensitivity mass sensors

    DEFF Research Database (Denmark)

    Davis, Zachary James; Boisen, Anja

    2005-01-01

    We have fabricated Al nanocantilevers using a simple, one mask contact UV lithography technique with lateral and vertical dimensions under 500 and 100 nm, respectively. These devices are demonstrated as highly sensitive mass sensors by measuring their dynamic properties. Furthermore, it is shown ...

  3. The Pajarito Monitor: a high-sensitivity monitoring system for highly enriched uranium

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.; Garcia, C.; Martinez, J.

    1984-01-01

    The Pajarito Monitor for Special Nuclear Material is a high-sensitivity gamma-ray monitoring system for detecting small quantities of highly enriched uranium transported by pedestrians or motor vehicles. The monitor consists of two components: a walk-through personnel monitor and a vehicle monitor. The personnel monitor has a plastic-scintillator detector portal, a microwave occupancy monitor, and a microprocessor control unit that measures the radiation intensity during background and monitoring periods to detect transient diversion signals. The vehicle monitor examines stationary motor vehicles while the vehicle's occupants pass through the personnel portal to exchange their badges. The vehicle monitor has four groups of large plastic scintillators that scan the vehicle from above and below. Its microprocessor control unit measures separate radiation intensities in each detector group. Vehicle occupancy is sensed by a highway traffic detection system. Each monitor's controller is responsible for detecting diversion as well as serving as a calibration and trouble-shooting aid. Diversion signals are detected by a sequential probability ratio hypothesis test that minimizes the monitoring time in the vehicle monitor and adapts itself well to variations in individual passage speed in the personnel monitor. Designed to be highly sensitive to diverted enriched uranium, the monitoring system also exhibits exceptional sensitivity for plutonium

  4. An Underwater Acoustic Vector Sensor with High Sensitivity and Broad Band

    Directory of Open Access Journals (Sweden)

    Hu Zhang

    2014-05-01

    Full Text Available Recently, acoustic vector sensor that use accelerators as sensing elements are widely used in underwater acoustic engineering, but the sensitivity of which at low frequency band is usually lower than -220 dB. In this paper, using a piezoelectric trilaminar optimized low frequency sensing element, we designed a high sensitivity internal placed ICP piezoelectric accelerometer as sensing element. Through structure optimization, we made a high sensitivity, broadband, small scale vector sensor. The working band is 10-2000 Hz, sound pressure sensitivity is -185 dB (at 100 Hz, outer diameter is 42 mm, length is 80 mm.

  5. Intracoronary and systemic melatonin to patients with acute myocardial infarction

    DEFF Research Database (Denmark)

    Halladin, Natalie L; Busch, Sarah Ekeløf; Jensen, Svend Eggert

    2014-01-01

    -point is the Myocardial Salvage Index assessed by cardiovascular magnetic resonance imaging on day 4 (± 1) after pPCI. The secondary end-points are high-sensitivity troponin, creatinekinase myocardial band and clinical events. CONCLUSION: The aim of the IMPACT trial is to evaluate the effect of melatonin on reperfusion...

  6. Retrospective Evaluation of Two Fast-track Strategies to Rule Out Acute Coronary Syndrome in a Real-life Chest Pain Population

    DEFF Research Database (Denmark)

    Schønemann-Lund, Martin; Schoos, Mikkel Malby; Iversen, Kasper

    2015-01-01

    BACKGROUND: The European Society of Cardiology (ESC) guideline on non-ST-elevation acute coronary syndrome (N-STE ACS) proposed a new ACS rule-out protocol. OBJECTIVES: To evaluate this new tool, which uses diagnostic levels of high-sensitivity troponin T (hs-TnT; > 14 ng/L) in a slightly modifie...

  7. Cardiac Stress and Inflammatory Markers as Predictors of Heart Failure in Patients With Type 2 Diabetes : The ADVANCE Trial

    NARCIS (Netherlands)

    Ohkuma, Toshiaki; Jun, Min; Woodward, Mark; Zoungas, Sophia; Cooper, Mark E; Grobbee, Diederick E; Hamet, Pavel; Mancia, Giuseppe; Williams, Bryan; Welsh, Paul; Sattar, Naveed; Shaw, Jonathan E.; Rahimi, Kazem; Chalmers, John

    OBJECTIVE: This study examined the individual and combined effect of N-terminal pro-B-type natriuretic peptide (NT-proBNP), high-sensitivity cardiac troponin T (hs-cTnT), interleukin-6 (IL-6), and hs-CRP on the prediction of heart failure incidence or progression in patients with type 2 diabetes.

  8. Genotype-specific pathogenic effects in human dilated cardiomyopathy.

    Science.gov (United States)

    Bollen, Ilse A E; Schuldt, Maike; Harakalova, Magdalena; Vink, Aryan; Asselbergs, Folkert W; Pinto, Jose R; Krüger, Martina; Kuster, Diederik W D; van der Velden, Jolanda

    2017-07-15

    Mutations in genes encoding cardiac troponin I (TNNI3) and cardiac troponin T (TNNT2) caused altered troponin protein stoichiometry in patients with dilated cardiomyopathy. TNNI3 p.98trunc resulted in haploinsufficiency, increased Ca 2+ -sensitivity and reduced length-dependent activation. TNNT2 p.K217del caused increased passive tension. A mutation in the gene encoding Lamin A/C (LMNA p.R331Q ) led to reduced maximal force development through secondary disease remodelling in patients suffering from dilated cardiomyopathy. Our study shows that different gene mutations induce dilated cardiomyopathy via diverse cellular pathways. Dilated cardiomyopathy (DCM) can be caused by mutations in sarcomeric and non-sarcomeric genes. In this study we defined the pathogenic effects of three DCM-causing mutations: the sarcomeric mutations in genes encoding cardiac troponin I (TNNI3 p.98truncation ) and cardiac troponin T (TNNT2 p.K217deletion ; also known as the p.K210del) and the non-sarcomeric gene mutation encoding lamin A/C (LMNA p.R331Q ). We assessed sarcomeric protein expression and phosphorylation and contractile behaviour in single membrane-permeabilized cardiomyocytes in human left ventricular heart tissue. Exchange with recombinant troponin complex was used to establish the direct pathogenic effects of the mutations in TNNI3 and TNNT2. The TNNI3 p.98trunc and TNNT2 p.K217del mutation showed reduced expression of troponin I to 39% and 51%, troponin T to 64% and 53%, and troponin C to 73% and 97% of controls, respectively, and altered stoichiometry between the three cardiac troponin subunits. The TNNI3 p.98trunc showed pure haploinsufficiency, increased Ca 2+ -sensitivity and impaired length-dependent activation. The TNNT2 p.K217del mutation showed a significant increase in passive tension that was not due to changes in titin isoform composition or phosphorylation. Exchange with wild-type troponin complex corrected troponin protein levels to 83% of controls in the TNNI3

  9. Importância da troponina-I cardíaca nos portadores de obstrução no tronco da artéria coronária esquerda sem evento cardíaco prévio Importance of cardiac troponin-I in the preoperative period of patients without prior cardiac events but suffering from left coronary branch obstruction

    Directory of Open Access Journals (Sweden)

    Domingo M. Braile

    2004-12-01

    suffering from left coronary branch obstruction but without prior cardiac events. METHOD: The cardiac troponin-I serum levels of 115 patients with obstructive coronary disease were analyzed. The ages of the patients varied between 32 and 81 years old with a mean age and standard deviation of 59.7 ± 10.5 years. The patients were divided into two groups: Group A, 41 patients suffering from left coronary branch obstruction with the degree of obstruction varying between 20% to subtotal occlusion (about 60% and Group B, 74 patients without left coronary branch obstruction. All the patients were submitted to catheterism and no evidence of previous acute myocardial infarction (AMI was identified. Chemoluminescence was utilized to measure the cardiac troponin-I level using the Sanofi-Pasteur Access apparatus, with values of less than 0.l nanograms per milliliter (ng/ml considered normal. RESULTS: No association was evidenced between the degree of left coronary branch obstruction and troponin-Ic serum levels (P= 0.4617, however the average serum levels of troponin-I, in Groups A and B were 0.3841 ng/mL and 0.1711 ng/mL respectively (P=0.0324 Mann-Whitney test; OR = 4.44 95% CI 1.60 - 12.31. CONCLUSIONS: The patients of Group A have 3.44 times higher chance of presenting with myocardial injury as identified by increased cardiac troponin-I levels than Group B, independent of the degree of left coronary branch obstruction. The sensitivity of clinical suspicion of myonecrosis was relatively low (31.7%, but the specificity was high (90.5%. However the clinical importance of the documentation of myonecrosis in a determined percentage of patients with branch injury without electrocardiographic evidence is stressed. Thus, patients with left coronary branch obstruction should be quickly submitted to operative procedures, in order to avoid worsening of the myonecrosis.

  10. High-intensity xenon plasma discharge lamp for bulk-sensitive high-resolution photoemission spectroscopy.

    Science.gov (United States)

    Souma, S; Sato, T; Takahashi, T; Baltzer, P

    2007-12-01

    We have developed a highly brilliant xenon (Xe) discharge lamp operated by microwave-induced electron cyclotron resonance (ECR) for ultrahigh-resolution bulk-sensitive photoemission spectroscopy (PES). We observed at least eight strong radiation lines from neutral or singly ionized Xe atoms in the energy region of 8.4-10.7 eV. The photon flux of the strongest Xe I resonance line at 8.437 eV is comparable to that of the He Ialpha line (21.218 eV) from the He-ECR discharge lamp. Stable operation for more than 300 h is achieved by efficient air-cooling of a ceramic tube in the resonance cavity. The high bulk sensitivity and high-energy resolution of PES using the Xe lines are demonstrated for some typical materials.

  11. High-speed high-sensitivity infrared spectroscopy using mid-infrared swept lasers (Conference Presentation)

    Science.gov (United States)

    Childs, David T. D.; Groom, Kristian M.; Hogg, Richard A.; Revin, Dmitry G.; Cockburn, John W.; Rehman, Ihtesham U.; Matcher, Stephen J.

    2016-03-01

    Infrared spectroscopy is a highly attractive read-out technology for compositional analysis of biomedical specimens because of its unique combination of high molecular sensitivity without the need for exogenous labels. Traditional techniques such as FTIR and Raman have suffered from comparatively low speed and sensitivity however recent innovations are challenging this situation. Direct mid-IR spectroscopy is being speeded up by innovations such as MEMS-based FTIR instruments with very high mirror speeds and supercontinuum sources producing very high sample irradiation levels. Here we explore another possible method - external cavity quantum cascade lasers (EC-QCL's) with high cavity tuning speeds (mid-IR swept lasers). Swept lasers have been heavily developed in the near-infrared where they are used for non-destructive low-coherence imaging (OCT). We adapt these concepts in two ways. Firstly by combining mid-IR quantum cascade gain chips with external cavity designs adapted from OCT we achieve spectral acquisition rates approaching 1 kHz and demonstrate potential to reach 100 kHz. Secondly we show that mid-IR swept lasers share a fundamental sensitivity advantage with near-IR OCT swept lasers. This makes them potentially able to achieve the same spectral SNR as an FTIR instrument in a time x N shorter (N being the number of spectral points) under otherwise matched conditions. This effect is demonstrated using measurements of a PDMS sample. The combination of potentially very high spectral acquisition rates, fundamental SNR advantage and the use of low-cost detector systems could make mid-IR swept lasers a powerful technology for high-throughput biomedical spectroscopy.

  12. Development of high sensitivity and high speed large size blank inspection system LBIS

    Science.gov (United States)

    Ohara, Shinobu; Yoshida, Akinori; Hirai, Mitsuo; Kato, Takenori; Moriizumi, Koichi; Kusunose, Haruhiko

    2017-07-01

    The production of high-resolution flat panel displays (FPDs) for mobile phones today requires the use of high-quality large-size photomasks (LSPMs). Organic light emitting diode (OLED) displays use several transistors on each pixel for precise current control and, as such, the mask patterns for OLED displays are denser and finer than the patterns for the previous generation displays throughout the entire mask surface. It is therefore strongly demanded that mask patterns be produced with high fidelity and free of defect. To enable the production of a high quality LSPM in a short lead time, the manufacturers need a high-sensitivity high-speed mask blank inspection system that meets the requirement of advanced LSPMs. Lasertec has developed a large-size blank inspection system called LBIS, which achieves high sensitivity based on a laser-scattering technique. LBIS employs a high power laser as its inspection light source. LBIS's delivery optics, including a scanner and F-Theta scan lens, focus the light from the source linearly on the surface of the blank. Its specially-designed optics collect the light scattered by particles and defects generated during the manufacturing process, such as scratches, on the surface and guide it to photo multiplier tubes (PMTs) with high efficiency. Multiple PMTs are used on LBIS for the stable detection of scattered light, which may be distributed at various angles due to irregular shapes of defects. LBIS captures 0.3mμ PSL at a detection rate of over 99.5% with uniform sensitivity. Its inspection time is 20 minutes for a G8 blank and 35 minutes for G10. The differential interference contrast (DIC) microscope on the inspection head of LBIS captures high-contrast review images after inspection. The images are classified automatically.

  13. High-resolution, high-sensitivity NMR of nano-litre anisotropic samples by coil spinning

    Energy Technology Data Exchange (ETDEWEB)

    Sakellariou, D [CEA Saclay, DSM, DRECAM, SCM, Lab Struct and Dynam Resonance Magnet, CNRS URA 331, F-91191 Gif Sur Yvette, (France); Le Goff, G; Jacquinot, J F [CEA Saclay, DSM, DRECAM, SPEC: Serv Phys Etat Condense, CNRS URA 2464, F-91191 Gif Sur Yvette, (France)

    2007-07-01

    Nuclear magnetic resonance (NMR) can probe the local structure and dynamic properties of liquids and solids, making it one of the most powerful and versatile analytical methods available today. However, its intrinsically low sensitivity precludes NMR analysis of very small samples - as frequently used when studying isotopically labelled biological molecules or advanced materials, or as preferred when conducting high-throughput screening of biological samples or 'lab-on-a-chip' studies. The sensitivity of NMR has been improved by using static micro-coils, alternative detection schemes and pre-polarization approaches. But these strategies cannot be easily used in NMR experiments involving the fast sample spinning essential for obtaining well-resolved spectra from non-liquid samples. Here we demonstrate that inductive coupling allows wireless transmission of radio-frequency pulses and the reception of NMR signals under fast spinning of both detector coil and sample. This enables NMR measurements characterized by an optimal filling factor, very high radio-frequency field amplitudes and enhanced sensitivity that increases with decreasing sample volume. Signals obtained for nano-litre-sized samples of organic powders and biological tissue increase by almost one order of magnitude (or, equivalently, are acquired two orders of magnitude faster), compared to standard NMR measurements. Our approach also offers optimal sensitivity when studying samples that need to be confined inside multiple safety barriers, such as radioactive materials. In principle, the co-rotation of a micrometer-sized detector coil with the sample and the use of inductive coupling (techniques that are at the heart of our method) should enable highly sensitive NMR measurements on any mass-limited sample that requires fast mechanical rotation to obtain well-resolved spectra. The method is easy to implement on a commercial NMR set-up and exhibits improved performance with miniaturization, and we

  14. Multimode fiber tip Fabry-Perot cavity for highly sensitive pressure measurement.

    Science.gov (United States)

    Chen, W P; Wang, D N; Xu, Ben; Zhao, C L; Chen, H F

    2017-03-23

    We demonstrate an optical Fabry-Perot interferometer fiber tip sensor based on an etched end of multimode fiber filled with ultraviolet adhesive. The fiber device is miniature (with diameter of less than 60 μm), robust and low cost, in a convenient reflection mode of operation, and has a very high gas pressure sensitivity of -40.94 nm/MPa, a large temperature sensitivity of 213 pm/°C within the range from 55 to 85 °C, and a relatively low temperature cross-sensitivity of 5.2 kPa/°C. This device has a high potential in monitoring environment of high pressure.

  15. High mass resolution time of flight mass spectrometer for measuring products in heterogeneous catalysis in highly sensitive microreactors

    DEFF Research Database (Denmark)

    Andersen, Thomas; Jensen, Robert; Christensen, M. K.

    2012-01-01

    We demonstrate a combined microreactor and time of flight system for testing and characterization of heterogeneous catalysts with high resolution mass spectrometry and high sensitivity. Catalyst testing is performed in silicon-based microreactors which have high sensitivity and fast thermal...

  16. Achieving sensitive, high-resolution laser spectroscopy at CRIS

    Energy Technology Data Exchange (ETDEWEB)

    Groote, R. P. de [Instituut voor Kern- en Stralingsfysica, KU Leuven (Belgium); Lynch, K. M., E-mail: kara.marie.lynch@cern.ch [EP Department, CERN, ISOLDE (Switzerland); Wilkins, S. G. [The University of Manchester, School of Physics and Astronomy (United Kingdom); Collaboration: the CRIS collaboration

    2017-11-15

    The Collinear Resonance Ionization Spectroscopy (CRIS) experiment, located at the ISOLDE facility, has recently performed high-resolution laser spectroscopy, with linewidths down to 20 MHz. In this article, we present the modifications to the beam line and the newly-installed laser systems that have made sensitive, high-resolution measurements possible. Highlights of recent experimental campaigns are presented.

  17. Highly efficient and stable cyclometalated ruthenium(II) complexes as sensitizers for dye-sensitized solar cells

    International Nuclear Information System (INIS)

    Huang, Jian-Feng; Liu, Jun-Min; Su, Pei-Yang; Chen, Yi-Fan; Shen, Yong; Xiao, Li-Min; Kuang, Dai-Bin; Su, Cheng-Yong

    2015-01-01

    Highlights: • Four novel thiocyanate-free cyclometalated ruthenium sensitizer were conveniently synthesized. • The D-CF 3 -sensitized DSSCs show higher efficiency compared to N719 based cells. • The DSSCs based on D-CF 3 and D-bisCF 3 sensitizers exhibit excellent long-term stability. • The diverse cyclometalated Ru complexes can be developed as high-performance sensitizers for use in DSSC. - Abstract: Four novel thiocyanate-free cyclometallted Ru(II) complexes, D-bisCF 3 , D-CF 3 , D-OMe, and D-DPA, with two 4,4′-dicarboxylic acid-2,2′-bipyridine together with a functionalized phenylpyridine ancillary ligand, have been designed and synthesized. The effect of different substituents (R = bisCF 3 , CF 3 , OMe, and DPA) on the ancillary C^N ligand on the photophysical properties and photovoltaic performance is investigated. Under standard global AM 1.5 solar conditions, the device based on D-CF 3 sensitizer gives a higher conversion efficiency of 8.74% than those based on D-bisCF 3 , D-OMe, and D-DPA, which can be ascribed to its broad range of visible light absorption, appropriate localization of the frontier orbitals, weak hydrogen bonds between -CF 3 and -OH groups at the TiO 2 surface, moderate dye loading on TiO 2 , and high charge collection efficiency. Moreover, the D-bisCF 3 and D-CF 3 based DSSCs exhibit good stability under 100 mW cm −2 light soaking at 60 °C for 400 h

  18. Modelling Ca2+ bound Troponin in Excitation Contraction Coupling

    Directory of Open Access Journals (Sweden)

    Henry G. Zot

    2016-09-01

    Full Text Available To explain disparate decay rates of cytosolic Ca2+ and structural changes in the thin filaments during a twitch, we model the time course of Ca2+ bound troponin (Tn resulting from the free Ca2+ transient of fast skeletal muscle. In fibers stretched beyond overlap, the decay of Ca2+ as measured by a change in fluo 3 fluorescence is significantly slower than the intensity decay of the meridional 1/38.5 nm-1 reflection of Tn; this is not simply explained by considering only the Ca2+ binding properties of Tn alone (Matsuo, T., Iwamoto, H., and Yagi, N. (2010. Biophys. J. 99, 193-200. We apply a comprehensive model that includes the known Ca2+ binding properties of Tn in the context of the thin filament with and without cycling crossbridges. Calculations based on the model predict that the transient of Ca2+ bound Tn correlates with either the fluo 3 time course in muscle with overlapping thin and thick filaments or the intensity of the meridional 1/38.5 nm-1 reflection in overstretched muscle. Hence, cycling crossbridges delay the dissociation of Ca2+ from Tn. Correlation with the fluo 3 fluorescence change is not causal given that the transient of Ca2+ bound Tn depends on sarcomere length, whereas the fluo-3 fluorescence change does not. Transient positions of tropomyosin calculated from the time course of Ca2+ bound Tn are in reasonable agreement with the transient of measured perturbations of the Tn repeat in overlap and non-overlap muscle preparations.

  19. Are inflationary predictions sensitive to very high energy physics?

    International Nuclear Information System (INIS)

    Burgess, C.P.; Lemieux, F.; Holman, R.; Cline, J.M.

    2003-01-01

    It has been proposed that the successful inflationary description of density perturbations on cosmological scales is sensitive to the details of physics at extremely high (trans-Planckian) energies. We test this proposal by examining how inflationary predictions depend on higher-energy scales within a simple model where the higher-energy physics is well understood. We find the best of all possible worlds: inflationary predictions are robust against the vast majority of high-energy effects, but can be sensitive to some effects in certain circumstances, in a way which does not violate ordinary notions of decoupling. This implies both that the comparison of inflationary predictions with CMB data is meaningful, and that it is also worth searching for small deviations from the standard results in the hopes of learning about very high energies. (author)

  20. Desensitization protocol in highly HLA-sensitized and ABO-incompatible high titer kidney transplantation.

    Science.gov (United States)

    Uchida, J; Machida, Y; Iwai, T; Naganuma, T; Kitamoto, K; Iguchi, T; Maeda, S; Kamada, Y; Kuwabara, N; Kim, T; Nakatani, T

    2010-12-01

    A positive crossmatch indicates the presence of donor-specific alloantibodies and is associated with a graft loss rate of >80%; anti-ABO blood group antibodies develop in response to exposure to foreign blood groups, resulting in immediate graft loss. However, a desensitization protocol for highly HLA-sensitized and ABO-incompatible high-titer kidney transplantation has not yet been established. We treated 6 patients with high (≥1:512) anti-A/B antibody titers and 2 highly HLA-sensitized patients. Our immunosuppression protocol was initiated 1 month before surgery and included mycophenolate mofetil (1 g/d) and/or low-dose steroid (methylprednisolone 8 mg/d). Two doses of the anti-CD20 antibody rituximab (150 mg/m(2)) were administered 2 weeks before and on the day of transplantation. We performed antibody removal with 6-12 sessions of plasmapheresis (plasma exchange or double-filtration plasmapheresis) before transplantation. Splenectomy was also performed on the day of transplantation. Postoperative immunosuppression followed the same regimen as ABO-compatible cases, in which calcineurin inhibitors were initiated 3 days before transplantation, combined with 2 doses of basiliximab. Of the 8 patients, 7 subsequently underwent successful living-donor kidney transplantation. Follow-up of our recipients showed that the patient and graft survival rates were 100%. Acute cellular rejection and antibody-mediated rejection episodes occurred in 1 of the 7 recipients. These findings suggest that our immunosuppression regimen consisting of rituximab infusions, splenectomy, plasmapheresis, and pharmacologic immunosuppression may prove to be effective as a desensitization protocol for highly HLA-sensitized and ABO-incompatible high-titer kidney transplantation. Copyright © 2010 Elsevier Inc. All rights reserved.

  1. Depleted Nanocrystal-Oxide Heterojunctions for High-Sensitivity Infrared Detection

    Science.gov (United States)

    2015-08-28

    Approved for Public Release; Distribution Unlimited Final Report: 4.3 Electronic Sensing - Depleted Nanocrystal- Oxide Heterojunctions for High...reviewed journals: Final Report: 4.3 Electronic Sensing - Depleted Nanocrystal- Oxide Heterojunctions for High-Sensitivity Infrared Detection Report Title...PERCENT_SUPPORTEDNAME FTE Equivalent: Total Number: 1 1 Final Progress Report Project title: Depleted Nanocrystal- Oxide Heterojunctions for High

  2. Covalent immobilisation of antibodies in Teflon-FEP microfluidic devices for the sensitive quantification of clinically relevant protein biomarkers.

    Science.gov (United States)

    Pivetal, Jeremy; Pereira, Filipa M; Barbosa, Ana I; Castanheira, Ana P; Reis, Nuno M; Edwards, Alexander D

    2017-03-13

    This study reports for the first time the sensitive colorimetric and fluorescence detection of clinically relevant protein biomarkers by sandwich immunoassays using the covalent immobilisation of antibodies onto the fluoropolymer surface inside Teflon®-FEP microfluidic devices. Teflon®-FEP has outstanding optical transparency ideal for high-sensitivity colorimetric and fluorescence bioassays, however this thermoplastic is regarded as chemically inert and very hydrophobic. Covalent immobilisation can offer benefits over passive adsorption to plastic surfaces by allowing better control over antibody density, orientation and analyte binding capacity, and so we tested a range of different and novel covalent immobilisation strategies. We first functionalised the inner surface of a 10-bore, 200 μm internal diameter FEP microcapillary film with high-molecular weight polyvinyl alcohol (PVOH) without changing the outstanding optical transparency of the device delivered by the matched refractive index of FEP and water. Glutaraldehyde immobilisation was compared with the use of photoactivated linkers and NHS-ester crosslinkers for covalently immobilising capture antibodies onto PVOH. Three clinically relevant sandwich ELISAs were tested against the cytokine IL-1β, the myocardial infarct marker cardiac troponin I (cTnI), and the chronic heart failure marker brain natriuretic peptide (BNP). Overall, glutaraldehyde immobilisation was effective for BNP assays, but yielded unacceptable background for IL-1β and cTnI assays caused by direct binding of the biotinylated detection antibody to the modified PVOH surface. We found NHS-ester groups reacted with APTES-treated PVOH coated fluoropolymers. This facilitated a novel method for capture antibody immobilisation onto fluoropolymer devices using a bifunctional NHS-maleimide crosslinker. The density of covalently immobilised capture antibodies achieved using PVOH/APTES/NHS/maleimide approached levels seen with passive adsorption

  3. Design of highly sensitive multichannel bimetallic photonic crystal fiber biosensor

    Science.gov (United States)

    Hameed, Mohamed Farhat O.; Alrayk, Yassmin K. A.; Shaalan, Abdelhamid A.; El Deeb, Walid S.; Obayya, Salah S. A.

    2016-10-01

    A design of a highly sensitive multichannel biosensor based on photonic crystal fiber is proposed and analyzed. The suggested design has a silver layer as a plasmonic material coated by a gold layer to protect silver oxidation. The reported sensor is based on detection using the quasi transverse electric (TE) and quasi transverse magnetic (TM) modes, which offers the possibility of multichannel/multianalyte sensing. The numerical results are obtained using a finite element method with perfect matched layer boundary conditions. The sensor geometrical parameters are optimized to achieve high sensitivity for the two polarized modes. High-refractive index sensitivity of about 4750 nm/RIU (refractive index unit) and 4300 nm/RIU with corresponding resolutions of 2.1×10-5 RIU, and 2.33×10-5 RIU can be obtained according to the quasi TM and quasi TE modes of the proposed sensor, respectively. Further, the reported design can be used as a self-calibration biosensor within an unknown analyte refractive index ranging from 1.33 to 1.35 with high linearity and high accuracy. Moreover, the suggested biosensor has advantages in terms of compactness and better integration of microfluidics setup, waveguide, and metallic layers into a single structure.

  4. Serine Protease Zymography: Low-Cost, Rapid, and Highly Sensitive RAMA Casein Zymography.

    Science.gov (United States)

    Yasumitsu, Hidetaro

    2017-01-01

    To detect serine protease activity by zymography, casein and CBB stain have been used as a substrate and a detection procedure, respectively. Casein zymography has been using substrate concentration at 1 mg/mL and employing conventional CBB stain. Although ordinary casein zymography provides reproducible results, it has several disadvantages including time-consuming and relative low sensitivity. Improved casein zymography, RAMA casein zymography, is rapid and highly sensitive. RAMA casein zymography completes the detection process within 1 h after incubation and increases the sensitivity at least by tenfold. In addition to serine protease, the method also detects metalloprotease 7 (MMP7, Matrilysin) with high sensitivity.

  5. Effect of radiation-induced heart injury on content of cardiac troponin I and endothelin-1 in SD rats

    International Nuclear Information System (INIS)

    Xu Jiuhong; Gao Yaoming; Zhang Junning; Li Xinli

    2011-01-01

    Objective: To investigate the effect of radiation-induced heart injury (RIHD) on cardiac endothelin-1 (ET-1) and cardiac troponin I (cTnI) in SD rats, and the possibility regarding ET-1 and cTnI as biomarker of RIHD was also explored. Methods: Healthy female SD rats were randomly divided into two groups: the control group (C) and irradiation group (R). The rats in R group were irradiated with linear accelerator at a single dose of 25 Gy. Five milliliters blood was collected from the inferior vena cava on the 5th, 15th, 30th, 60th day after radiation. Blood was centrifuged and serum was collected. Content of ET-1 and cTnI in blood serum were detected by ELISA kits. Results: The content of ET-1 in the R group was always higher than that in the C group (P<0.01) during the whole process, and the difference between two groups had statistical significance only on the 5th day (P<0.01) and 15th day (P<0.05) after radiation. However, the content of cTnI in R group was higher than that in the C group within 30 days after radiation, then decreased, and only on the 15th day (P<0.05) and the 30th day (P<0.01) after radiation, there was statistical difference between two groups. Conclusion: The content of ET-1 and cTnI in blood serum increase obviously after receiving RIHD, so these two indicators can be used as markers to diagnose early RIHD sensitively and specifically. (authors)

  6. Aluminum nano-cantilevers for high sensitivity mass sensors

    DEFF Research Database (Denmark)

    Davis, Zachary James; Boisen, Anja

    2005-01-01

    We have fabricated Al nano-cantilevers using a very simple one mask contact UV lithography technique with lateral dimensions under 500 nm and vertical dimensions of approximately 100 nm. These devices are demonstrated as highly sensitive mass sensors by measuring their dynamic properties. Further...

  7. Prototype of high resolution PET using resistive electrode position sensitive CdTe detectors

    International Nuclear Information System (INIS)

    Kikuchi, Yohei; Ishii, Keizo; Matsuyama, Shigeo; Yamazaki, Hiromichi

    2008-01-01

    Downsizing detector elements makes it possible that spatial resolutions of positron emission tomography (PET) cameras are improved very much. From this point of view, semiconductor detectors are preferable. To obtain high resolution, the pixel type or the multi strip type of semiconductor detectors can be used. However, in this case, there is a low packing ratio problem, because a dead area between detector arrays cannot be neglected. Here, we propose the use of position sensitive semiconductor detectors with resistive electrode. The CdTe detector is promising as a detector for PET camera because of its high sensitivity. In this paper, we report development of prototype of high resolution PET using resistive electrode position sensitive CdTe detectors. We made 1-dimensional position sensitive CdTe detectors experimentally by changing the electrode thickness. We obtained 750 A as an appropriate thickness of position sensitive detectors, and evaluated the performance of the detector using a collimated 241 Am source. A good position resolution of 1.2 mm full width half maximum (FWHM) was obtained. On the basis of the fundamental development of resistive electrode position sensitive detectors, we constructed a prototype of high resolution PET which was a dual head type and was consisted of thirty-two 1-dimensional position sensitive detectors. In conclusion, we obtained high resolutions which are 0.75 mm (FWHM) in transaxial, and 1.5 mm (FWHM) in axial. (author)

  8. Low Cost, Low Power, High Sensitivity Magnetometer

    Science.gov (United States)

    2008-12-01

    which are used to measure the small magnetic signals from brain. Other types of vector magnetometers are fluxgate , coil based, and magnetoresistance...concentrator with the magnetometer currently used in Army multimodal sensor systems, the Brown fluxgate . One sees the MEMS fluxgate magnetometer is...Guedes, A.; et al., 2008: Hybrid - LOW COST, LOW POWER, HIGH SENSITIVITY MAGNETOMETER A.S. Edelstein*, James E. Burnette, Greg A. Fischer, M.G

  9. Highly sensitive assay for tyrosine hydroxylase activity by high-performance liquid chromatography.

    Science.gov (United States)

    Nagatsu, T; Oka, K; Kato, T

    1979-07-21

    A highly sensitive assay for tyrosine hydroxylase (TH) activity by high-performance liquid chromatography (HPLC) with amperometric detection was devised based on the rapid isolation of enzymatically formed DOPA by a double-column procedure, the columns fitted together sequentially (the top column of Amberlite CG-50 and the bottom column of aluminium oxide). DOPA was adsorbed on the second aluminium oxide column, then eluted with 0.5 M hydrochloric acid, and assayed by HPLC with amperometric detection. D-Tyrosine was used for the control. alpha-Methyldopa was added to the incubation mixture as an internal standard after incubation. This assay was more sensitive than radioassays and 5 pmol of DOPA formed enzymatically could be measured in the presence of saturating concentrations of tyrosine and 6-methyltetrahydropterin. The TH activity in 2 mg of human putamen could be easily measured, and this method was found to be particularly suitable for the assay of TH activity in a small number of nuclei from animal and human brain.

  10. Sensitive high performance liquid chromatographic method for the ...

    African Journals Online (AJOL)

    A new simple, sensitive, cost-effective and reproducible high performance liquid chromatographic (HPLC) method for the determination of proguanil (PG) and its metabolites, cycloguanil (CG) and 4-chlorophenylbiguanide (4-CPB) in urine and plasma is described. The extraction procedure is a simple three-step process ...

  11. Review of high-sensitivity Radon studies

    Science.gov (United States)

    Wojcik, M.; Zuzel, G.; Simgen, H.

    2017-10-01

    A challenge in many present cutting-edge particle physics experiments is the stringent requirements in terms of radioactive background. In peculiar, the prevention of Radon, a radioactive noble gas, which occurs from ambient air and it is also released by emanation from the omnipresent progenitor Radium. In this paper we review various high-sensitivity Radon detection techniques and approaches, applied in the experiments looking for rare nuclear processes happening at low energies. They allow to identify, quantitatively measure and finally suppress the numerous sources of Radon in the detectors’ components and plants.

  12. Recent trends in high spin sensitivity magnetic resonance

    Science.gov (United States)

    Blank, Aharon; Twig, Ygal; Ishay, Yakir

    2017-07-01

    new ideas, show how these limiting factors can be mitigated to significantly improve the sensitivity of induction detection. Finally, we outline some directions for the possible applications of high-sensitivity induction detection in the field of electron spin resonance.

  13. A wide-bandwidth and high-sensitivity robust microgyroscope

    International Nuclear Information System (INIS)

    Sahin, Korhan; Sahin, Emre; Akin, Tayfun; Alper, Said Emre

    2009-01-01

    This paper reports a microgyroscope design concept with the help of a 2 degrees of freedom (DoF) sense mode to achieve a wide bandwidth without sacrificing mechanical and electronic sensitivity and to obtain robust operation against variations under ambient conditions. The design concept is demonstrated with a tuning fork microgyroscope fabricated with an in-house silicon-on-glass micromachining process. When the fabricated gyroscope is operated with a relatively wide bandwidth of 1 kHz, measurements show a relatively high raw mechanical sensitivity of 131 µV (° s −1 ) −1 . The variation in the amplified mechanical sensitivity (scale factor) of the gyroscope is measured to be less than 0.38% for large ambient pressure variations such as from 40 to 500 mTorr. The bias instability and angle random walk of the gyroscope are measured to be 131° h −1 and 1.15° h −1/2 , respectively

  14. Compton imaging with a highly-segmented, position-sensitive HPGe detector

    Energy Technology Data Exchange (ETDEWEB)

    Steinbach, T.; Hirsch, R.; Reiter, P.; Birkenbach, B.; Bruyneel, B.; Eberth, J.; Hess, H.; Lewandowski, L. [Universitaet zu Koeln, Institut fuer Kernphysik, Koeln (Germany); Gernhaeuser, R.; Maier, L.; Schlarb, M.; Weiler, B.; Winkel, M. [Technische Universitaet Muenchen, Physik Department, Garching (Germany)

    2017-02-15

    A Compton camera based on a highly-segmented high-purity germanium (HPGe) detector and a double-sided silicon-strip detector (DSSD) was developed, tested, and put into operation; the origin of γ radiation was determined successfully. The Compton camera is operated in two different modes. Coincidences from Compton-scattered γ-ray events between DSSD and HPGe detector allow for best angular resolution; while the high-efficiency mode takes advantage of the position sensitivity of the highly-segmented HPGe detector. In this mode the setup is sensitive to the whole 4π solid angle. The interaction-point positions in the 36-fold segmented large-volume HPGe detector are determined by pulse-shape analysis (PSA) of all HPGe detector signals. Imaging algorithms were developed for each mode and successfully implemented. The angular resolution sensitively depends on parameters such as geometry, selected multiplicity and interaction-point distances. Best results were obtained taking into account the crosstalk properties, the time alignment of the signals and the distance metric for the PSA for both operation modes. An angular resolution between 13.8 {sup circle} and 19.1 {sup circle}, depending on the minimal interaction-point distance for the high-efficiency mode at an energy of 1275 keV, was achieved. In the coincidence mode, an increased angular resolution of 4.6 {sup circle} was determined for the same γ-ray energy. (orig.)

  15. Novel charge sensitive preamplifier without high-value feedback resistor

    International Nuclear Information System (INIS)

    Xi Deming

    1992-01-01

    A novel charge sensitive preamplifier is introduced. The method of removing the high value feedback resistor, the circuit design and analysis are described. A practical circuit and its measured performances are provided

  16. Nuclear Scan Strategy and Outcomes in Chest Pain Patients Value of Stress Testing with Dipyridamole or Adenosine

    International Nuclear Information System (INIS)

    Conti, Alberto; Mariannini, Yuri; Canuti, Erica; Petrova, Tetyana; Innocenti, Francesca; Zanobetti, Maurizio; Gallini, Chiara; Costanzo, Egidio

    2014-01-01

    To update the prognostic value of scan strategy with pharmacological stress agent in chest pain (CP) patients presenting with normal electrocardiography (ECG) and troponin. Two consecutive nonrandomized series of patients with CP and negative first-line workup inclusive of serial ECG, serial troponin, and echocardiography underwent myocardial perfusion imaging single photon emission computed tomography (SPECT) in the emergency department. Of 170 patients enrolled, 52 patients underwent dipyridamole-SPECT and 118 adenosine-SPECT. Patients with perfusion defects underwent angiography, whereas the remaining patients were discharged and followed-up. Primary endpoint was the composite of nonfatal myocardial infarction, unstable angina, revascularization, and cardiovascular death at follow-up or the presence of coronary stenosis > 50% at angiography. At multivariate analysis, the presence of perfusion defects or hypertension was independent predictor of the primary endpoint. Sensitivity and negative predictive value were higher in patients subjected to adenosine-SPECT (95% and 99%, respectively) versus dipyridamole-SPECT (56% and 89%; yield 70% and 11%, respectively; P < 0.03). Of note, sensitivity, negative, and positive predictive values were high in patients with hypertension (100%, 93%, and 60%, respectively) or nonischemic echocardiography alterations (100%, 100%, and 100%, respectively). In CP patients, presenting with normal ECG and troponin, adenosine-SPECT adds incremental prognostic values to dipyridamole-SPECT. Costly scan strategy is more appropriate and avoids unnecessary angiograms in patients with hypertension or nonischemic echocardiography alterations

  17. BH3105 type neutron dose equivalent meter of high sensitivity

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Enshan; Yang Jianfeng; Zhang Hong; Huang Jiling

    1995-10-01

    It is noted that to design a neutron dose meter of high sensitivity is almost impossible in the frame of traditional designing principle--'absorption net principle'. Based on a newly proposed principle of obtaining neutron dose equi-biological effect adjustment--' absorption stick principle', a brand-new neutron dose-equivalent meter with high neutron sensitivity BH3105 has been developed. Its sensitivity reaches 10 cps/(μSv·h -1 ), which is 18∼40 times higher than one of foreign products of the same kind and is 10 4 times higher than that of domestic FJ342 neutron rem-meter. BH3105 has a measurement range from 0.1μSv/h to 1 Sv/h which is 1 or 2 orders wider than that of the other's. It has the advanced properties of gamma-resistance, energy response, orientation, etc. (6 tabs., 5 figs.)

  18. Monte carlo calculation of energy-dependent response of high-sensitive neutron monitor, HISENS

    International Nuclear Information System (INIS)

    Imanaka, Tetsuji; Ebisawa, Tohru; Kobayashi, Keiji; Koide, Hiroaki; Seo, Takeshi; Kawano, Shinji

    1988-01-01

    A highly sensitive neutron monitor system, HISENS, has been developed to measure leakage neutrons from nuclear facilities. The counter system of HISENS contains a detector bank which consists of ten cylindrical proportional counters filled with 10 atm 3 He gas and a paraffin moderator mounted in an aluminum case. The size of the detector bank is 56 cm high, 66 cm wide and 10 cm thick. It is revealed by a calibration experiment using an 241 Am-Be neutron source that the sensitivity of HISENS is about 2000 times as large as that of a typical commercial rem-counter. Since HISENS is designed to have a high sensitivity in a wide range of neutron energy, the shape of its energy dependent response curve cannot be matched to that of the dose equivalent conversion factor. To estimate dose equivalent values from neutron counts by HISENS, it is necessary to know the energy and angular characteristics of both HISENS and the neutron field. The area of one side of the detector bank is 3700 cm 2 and the detection efficiency in the constant region of the response curve is about 30 %. Thus, the sensitivity of HISENS for this energy range is 740 cps/(n/cm 2 /sec). This value indicates the extremely high sensitivity of HISENS as compared with exsisting highly sensitive neutron monitors. (Nogami, K.)

  19. CONSTRUCTION OF A DIFFERENTIAL ISOTHERMAL CALORIMETER OF HIGH SENSITIVITY AND LOW COST.

    OpenAIRE

    Trinca, RB; Perles, CE; Volpe, PLO

    2009-01-01

    CONSTRUCTION OF A DIFFERENTIAL ISOTHERMAL CALORIMETER OF HIGH SENSITIVITY AND LOW COST The high cost of sensitivity commercial calorimeters may represent an obstacle for many calorimetric research groups. This work describes (fie construction and calibration of a batch differential heat conduction calorimeter with sample cells volumes of about 400 mu L. The calorimeter was built using two small high sensibility square Peltier thermoelectric sensors and the total cost was estimated to be about...

  20. A high sensitivity process variation sensor utilizing sub-threshold operation

    OpenAIRE

    Meterelliyoz, Mesut; Song, Peilin; Stellari, Franco; Kulkarni, Jaydeep P.; Roy, Kaushik

    2008-01-01

    In this paper, we propose a novel low-power, bias-free, high-sensitivity process variation sensor for monitoring random variations in the threshold voltage. The proposed sensor design utilizes the exponential current-voltage relationship of sub-threshold operation thereby improving the sensitivity by 2.3X compared to the above-threshold operation. A test-chip containing 128 PMOS and 128 NMOS devices has been fabri...

  1. Sensitivity to apomorphine-induced yawning and hypothermia in rats eating standard or high-fat chow.

    Science.gov (United States)

    Baladi, Michelle G; Thomas, Yvonne M; France, Charles P

    2012-07-01

    Feeding conditions modify sensitivity to indirect- and direct-acting dopamine receptor agonists as well as the development of sensitization to these drugs. This study examined whether feeding condition affects acute sensitivity to apomorphine-induced yawning or changes in sensitivity that occur over repeated drug administration. Quinpirole-induced yawning was also evaluated to see whether sensitization to apomorphine confers cross-sensitization to quinpirole. Drug-induced yawning was measured in different groups of male Sprague Dawley rats (n = 6/group) eating high (34.3%) fat or standard (5.7% fat) chow. Five weeks of eating high-fat chow rendered otherwise drug-naïve rats more sensitive to apomorphine- (0.01-1.0 mg/kg, i.p.) and quinpirole- (0.0032-0.32 mg/kg, i.p.) induced yawning, compared with rats eating standard chow. In other rats, tested weekly with apomorphine, sensitivity to apomorphine-induced yawning increased (sensitization) similarly in rats with free access to standard or high-fat chow; conditioning to the testing environment appeared to contribute to increased yawning in both groups of rats. Food restriction decreased sensitivity to apomorphine-induced yawning across five weekly tests. Rats with free access to standard or high-fat chow and sensitized to apomorphine were cross-sensitized to quinpirole-induced yawning. The hypothermic effects of apomorphine and quinpirole were not different regardless of drug history or feeding condition. Eating high-fat chow or restricting access to food alters sensitivity to direct-acting dopamine receptor agonists (apomorphine, quinpirole), although the relative contribution of drug history and dietary conditions to sensitivity changes appears to vary among agonists.

  2. An UPLC-MS/MS method for highly sensitive high-throughput analysis of phytohormones in plant tissues

    Directory of Open Access Journals (Sweden)

    Balcke Gerd Ulrich

    2012-11-01

    Full Text Available Abstract Background Phytohormones are the key metabolites participating in the regulation of multiple functions of plant organism. Among them, jasmonates, as well as abscisic and salicylic acids are responsible for triggering and modulating plant reactions targeted against pathogens and herbivores, as well as resistance to abiotic stress (drought, UV-irradiation and mechanical wounding. These factors induce dramatic changes in phytohormone biosynthesis and transport leading to rapid local and systemic stress responses. Understanding of underlying mechanisms is of principle interest for scientists working in various areas of plant biology. However, highly sensitive, precise and high-throughput methods for quantification of these phytohormones in small samples of plant tissues are still missing. Results Here we present an LC-MS/MS method for fast and highly sensitive determination of jasmonates, abscisic and salicylic acids. A single-step sample preparation procedure based on mixed-mode solid phase extraction was efficiently combined with essential improvements in mobile phase composition yielding higher efficiency of chromatographic separation and MS-sensitivity. This strategy resulted in dramatic increase in overall sensitivity, allowing successful determination of phytohormones in small (less than 50 mg of fresh weight tissue samples. The method was completely validated in terms of analyte recovery, sensitivity, linearity and precision. Additionally, it was cross-validated with a well-established GC-MS-based procedure and its applicability to a variety of plant species and organs was verified. Conclusion The method can be applied for the analyses of target phytohormones in small tissue samples obtained from any plant species and/or plant part relying on any commercially available (even less sensitive tandem mass spectrometry instrumentation.

  3. Effect of Intracoronary and Intravenous Melatonin on Myocardial Salvage Index in Patients with ST-Elevation Myocardial Infarction

    DEFF Research Database (Denmark)

    Ekeloef, Sarah; Halladin, Natalie; Fonnes, Siv

    2017-01-01

    .0–63.6) and the placebo group (n = 19) at 61.5% (95% CI 57.5–65.5), p = 0.21. The levels of high-sensitive troponin T, creatinine kinase myocardial band, and oxidative biomarkers (advanced oxidation protein products, malondialdehyde, myeloperoxidase) were similar in the groups. The frequency of clinical events at 90 days...

  4. Eating high-fat chow enhances sensitization to the effects of methamphetamine on locomotion in rats.

    Science.gov (United States)

    McGuire, Blaine A; Baladi, Michelle G; France, Charles P

    2011-05-11

    Eating high-fat chow can modify the effects of drugs acting directly or indirectly on dopamine systems and repeated intermittent drug administration can markedly increase sensitivity (i.e., sensitization) to the behavioral effects of indirect-acting dopamine receptor agonists (e.g., methamphetamine). This study examined whether eating high-fat chow alters the sensitivity of male Sprague Dawley rats to the locomotor stimulating effects of acute or repeated administration of methamphetamine. The acute effects of methamphetamine on locomotion were not different between rats (n=6/group) eating high-fat or standard chow for 1 or 4 weeks. Sensitivity to the effects of methamphetamine (0.1-10mg/kg, i.p.) increased progressively across 4 once per week tests; this sensitization developed more rapidly and to a greater extent in rats eating high-fat chow as compared with rats eating standard chow. Thus, while eating high-fat chow does not appear to alter sensitivity of rats to acutely-administered methamphetamine, it significantly increases the sensitization that develops to repeated intermittent administration of methamphetamine. These data suggest that eating certain foods influences the development of sensitization to drugs acting on dopamine systems. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. High sensitivity amplifier/discriminator for PWC's

    International Nuclear Information System (INIS)

    Hansen, S.

    1983-01-01

    The facility support group at Fermilab is designing and building a general purpose beam chamber for use in several locations at the laboratory. This pwc has 128 wires per plane spaced 1 mm apart. An initial production of 25 signal planes is anticipated. In proportional chambers, the size of the signal depends exponentially on the charge stored per unit of length along the anode wire. As the wire spacing decreases, the capacitance per unit length decreases, thereby requiring increased applied voltage to restore the necessary charge per unit length. In practical terms, this phenomenon is responsible for difficulties in constructing chambers with less than 2 mm wire spacing. 1 mm chambers, therefore, are frequently operated very near to their breakdown point and/or a high gain gas containing organic compounds such as magic gas is used. This argon/iso-butane mixture has three drawbacks: it is explosive when exposed to the air, it leaves a residue on the wires after extended use and is costly. An amplifier with higher sensitivity would reduce the problems associated with operating chambers with small wire spacings and allow them to be run a safe margin below their breakdown voltage even with an inorganic gas mixture such as argon/CO2, this eliminating the need to use magic gas. Described here is a low cost amplifier with a usable threshold of less than 0.5 μA. Data on the performance of this amplifier/discriminator in operation on a prototype beam chamber are given. This data shows the advantages of the high sensitivity of this design

  6. A highly sensitive and specific assay for vertebrate collagenase

    International Nuclear Information System (INIS)

    Sodek, J.; Hurum, S.; Feng, J.

    1981-01-01

    A highly sensitive and specific assay for vertebrate collagenase has been developed using a [ 14 C]-labeled collagen substrate and a combination of SDS-PAGE (sodium dodecyl sulfate-polyacrylamide gel electrophoresis) and fluorography to identify and quantitate the digestion products. The assay was sufficiently sensitive to permit the detection and quantitation of collagenase activity in 0.1 μl of gingival sulcal fluid, and in samples of cell culture medium without prior concentration. The assay has also been used to detect the presence of inhibitors of collagenolytic enzymes in various cell culture fluids. (author)

  7. Comprehensive Characterization of Swine Cardiac Troponin T Proteoforms by Top-Down Mass Spectrometry

    Science.gov (United States)

    Lin, Ziqing; Guo, Fang; Gregorich, Zachery R.; Sun, Ruixiang; Zhang, Han; Hu, Yang; Shanmuganayagam, Dhanansayan; Ge, Ying

    2018-04-01

    Cardiac troponin T (cTnT) regulates the Ca2+-mediated interaction between myosin thick filaments and actin thin filaments during cardiac contraction and relaxation. cTnT is released into the blood following injury, and increased serum levels of the protein are used clinically as a biomarker for myocardial infarction. Moreover, mutations in cTnT are causative in a number of familial cardiomyopathies. With the increasing use of large animal (swine) model to recapitulate human diseases, it is essential to characterize species-dependent protein sequence variants, alternative RNA splicing, and post-translational modifications (PTMs), but challenges remain due to the incomplete database and lack of validation of the predicted splicing isoforms. Herein, we integrated top-down mass spectrometry (MS) with online liquid chromatography (LC) and immunoaffinity purification to comprehensively characterize miniature swine cTnT proteoforms, including those arising from alternative RNA splicing and PTMs. A total of seven alternative splicing isoforms of cTnT were identified by LC/MS from swine left ventricular tissue, with each isoform containing un-phosphorylated and mono-phosphorylated proteoforms. The phosphorylation site was localized to Ser1 for the mono-phosphorylated proteoforms of cTnT1, 3, 4, and 6 by online MS/MS combining collisionally activated dissociation (CAD) and electron transfer dissociation (ETD). Offline MS/MS on Fourier-transform ion cyclotron resonance (FT-ICR) mass spectrometer with CAD and electron capture dissociation (ECD) was then utilized to achieve deep sequencing of mono-phosphorylated cTnT1 (35.2 kDa) with a high sequence coverage of 87%. Taken together, this study demonstrated the unique advantage of top-down MS in the comprehensive characterization of protein alternative splicing isoforms together with PTMs. [Figure not available: see fulltext.

  8. Resting serum concentration of high-sensitivity C-reactive protein ...

    African Journals Online (AJOL)

    Resting serum concentration of high-sensitivity C-reactive protein (hs-CRP) in sportsmen and untrained male adults. F.A. Niyi-Odumosu, O. A. Bello, S.A. Biliaminu, B.V. Owoyele, T.O. Abu, O.L. Dominic ...

  9. ZnO nanorod biosensor for highly sensitive detection of specific protein binding

    International Nuclear Information System (INIS)

    Kim, Jin Suk; Park, Won Il; Lee, Chul Ho; Yi, Gyu Chul

    2006-01-01

    We report on the fabrication of electrical biosensors based on functionalized ZnO nanorod surfaces with biotin for highly sensitive detection of biological molecules. Due to the clean interface and easy surface modification, the ZnO nanorod sensors can easily detect streptavidin binding down to a concentration of 25 nM, which is more sensitive than previously reported one-dimensional (1D) nanostructure electrical biosensors. In addition, the unique device structure with a micrometer-scale hole at the center of the ZnO nanorod's conducting channel reduces the leakage current from the aqueous solution, hence enhancing device sensitivity. Moreover, ZnO nanorod field-effect-transistor (FET) sensors may open up opportunities to create many other oxide nanorod electrical sensors for highly sensitive and selective real-time detection of a wide variety of biomolecules.

  10. High Throughput Measurement of Locomotor Sensitization to Volatilized Cocaine in Drosophila melanogaster.

    Science.gov (United States)

    Filošević, Ana; Al-Samarai, Sabina; Andretić Waldowski, Rozi

    2018-01-01

    Drosophila melanogaster can be used to identify genes with novel functional roles in neuronal plasticity induced by repeated consumption of addictive drugs. Behavioral sensitization is a relatively simple behavioral output of plastic changes that occur in the brain after repeated exposures to drugs of abuse. The development of screening procedures for genes that control behavioral sensitization has stalled due to a lack of high-throughput behavioral tests that can be used in genetically tractable organism, such as Drosophila . We have developed a new behavioral test, FlyBong, which combines delivery of volatilized cocaine (vCOC) to individually housed flies with objective quantification of their locomotor activity. There are two main advantages of FlyBong: it is high-throughput and it allows for comparisons of locomotor activity of individual flies before and after single or multiple exposures. At the population level, exposure to vCOC leads to transient and concentration-dependent increase in locomotor activity, representing sensitivity to an acute dose. A second exposure leads to further increase in locomotion, representing locomotor sensitization. We validate FlyBong by showing that locomotor sensitization at either the population or individual level is absent in the mutants for circadian genes period (per) , Clock (Clk) , and cycle (cyc) . The locomotor sensitization that is present in timeless (tim) and pigment dispersing factor (pdf) mutant flies is in large part not cocaine specific, but derived from increased sensitivity to warm air. Circadian genes are not only integral part of the neural mechanism that is required for development of locomotor sensitization, but in addition, they modulate the intensity of locomotor sensitization as a function of the time of day. Motor-activating effects of cocaine are sexually dimorphic and require a functional dopaminergic transporter. FlyBong is a new and improved method for inducing and measuring locomotor sensitization

  11. High Throughput Measurement of Locomotor Sensitization to Volatilized Cocaine in Drosophila melanogaster

    Directory of Open Access Journals (Sweden)

    Ana Filošević

    2018-02-01

    Full Text Available Drosophila melanogaster can be used to identify genes with novel functional roles in neuronal plasticity induced by repeated consumption of addictive drugs. Behavioral sensitization is a relatively simple behavioral output of plastic changes that occur in the brain after repeated exposures to drugs of abuse. The development of screening procedures for genes that control behavioral sensitization has stalled due to a lack of high-throughput behavioral tests that can be used in genetically tractable organism, such as Drosophila. We have developed a new behavioral test, FlyBong, which combines delivery of volatilized cocaine (vCOC to individually housed flies with objective quantification of their locomotor activity. There are two main advantages of FlyBong: it is high-throughput and it allows for comparisons of locomotor activity of individual flies before and after single or multiple exposures. At the population level, exposure to vCOC leads to transient and concentration-dependent increase in locomotor activity, representing sensitivity to an acute dose. A second exposure leads to further increase in locomotion, representing locomotor sensitization. We validate FlyBong by showing that locomotor sensitization at either the population or individual level is absent in the mutants for circadian genes period (per, Clock (Clk, and cycle (cyc. The locomotor sensitization that is present in timeless (tim and pigment dispersing factor (pdf mutant flies is in large part not cocaine specific, but derived from increased sensitivity to warm air. Circadian genes are not only integral part of the neural mechanism that is required for development of locomotor sensitization, but in addition, they modulate the intensity of locomotor sensitization as a function of the time of day. Motor-activating effects of cocaine are sexually dimorphic and require a functional dopaminergic transporter. FlyBong is a new and improved method for inducing and measuring locomotor

  12. Cardiac complications in diphtheria and predictors of outcomes.

    Science.gov (United States)

    Samdani, Sunil; Jain, Avani; Meena, Vinod; Meena, C B

    2018-01-01

    To study the cardiac complications in diphtheria patients and to study the predictors of outcomes. Single centre prospective analysis of cardiac complications in diphtheria patients. In this study, there were 60 patients diagnosed with diphtheria with ECG changes. The ECG changes seen were sinus tachycardia (68.3%), T wave inversion (20%), ST segment depression (13.3%), right bundle branch block (5%), multiple atrial ectopics (3.3%). The case fatality rate in our study was 25% (15 patients). High CPK-MB, myoglobulin and cardiac troponin levels were associated with cardiac mortality. In our study, cardiac troponin T had the highest sensitivity (80%) and CK-MB had the highest specificity (95.56%). Cardiac involvement is a common complication of infection with C. diphtheria and is associated with high mortality. As diphtheria can be prevented by adequate vaccination, efforts should be maximized for high vaccine coverage with booster doses. Copyright © 2017. Published by Elsevier B.V.

  13. The Effect of a Diet Moderately High in Protein and Fiber on Insulin Sensitivity Measured Using the Dynamic Insulin Sensitivity and Secretion Test (DISST

    Directory of Open Access Journals (Sweden)

    Lisa Te Morenga

    2017-11-01

    Full Text Available Evidence shows that weight loss improves insulin sensitivity but few studies have examined the effect of macronutrient composition independently of weight loss on direct measures of insulin sensitivity. We randomised 89 overweight or obese women to either a standard diet (StdD, that was intended to be low in fat and relatively high in carbohydrate (n = 42 or to a relatively high protein (up to 30% of energy, relatively high fibre (>30 g/day diet (HPHFib (n = 47 for 10 weeks. Advice regarding strict adherence to energy intake goals was not given. Insulin sensitivity and secretion was assessed by a novel method—the Dynamic Insulin Sensitivity and Secretion Test (DISST. Although there were significant improvements in body composition and most cardiometabolic risk factors on HPHFib, insulin sensitivity was reduced by 19.3% (95% CI: 31.8%, 4.5%; p = 0.013 in comparison with StdD. We conclude that the reduction in insulin sensitivity after a diet relatively high in both protein and fibre, despite cardiometabolic improvements, suggests insulin sensitivity may reflect metabolic adaptations to dietary composition for maintenance of glucose homeostasis, rather than impaired metabolism.

  14. High Sensitivity TSS Prediction: Estimates of Locations Where TSS Cannot Occur

    KAUST Repository

    Schaefer, Ulf; Kodzius, Rimantas; Kai, Chikatoshi; Kawai, Jun; Carninci, Piero; Hayashizaki, Yoshihide; Bajic, Vladimir B.

    2013-01-01

    from mouse and human genomes, we developed a methodology that allows us, by performing computational TSS prediction with very high sensitivity, to annotate, with a high accuracy in a strand specific manner, locations of mammalian genomes that are highly

  15. Highly Sensitive Reentrant Cavity-Microstrip Patch Antenna Integrated Wireless Passive Pressure Sensor for High Temperature Applications

    Directory of Open Access Journals (Sweden)

    Fei Lu

    2017-01-01

    Full Text Available A novel reentrant cavity-microstrip patch antenna integrated wireless passive pressure sensor was proposed in this paper for high temperature applications. The reentrant cavity was analyzed from aspects of distributed model and equivalent lumped circuit model, on the basis of which an optimal sensor structure integrated with a rectangular microstrip patch antenna was proposed to better transmit/receive wireless signals. In this paper, the proposed sensor was fabricated with high temperature resistant alumina ceramic and silver metalization with weld sealing, and it was measured in a hermetic metal tank with nitrogen pressure loading. It was verified that the sensor was highly sensitive, keeping stable performance up to 300 kPa with an average sensitivity of 981.8 kHz/kPa at temperature 25°C, while, for high temperature measurement, the sensor can operate properly under pressure of 60–120 kPa in the temperature range of 25–300°C with maximum pressure sensitivity of 179.2 kHz/kPa. In practical application, the proposed sensor is used in a method called table lookup with a maximum error of 5.78%.

  16. Polarization-sensitive and broadband germanium sulfide photodetectors with excellent high-temperature performance.

    Science.gov (United States)

    Tan, Dezhi; Zhang, Wenjin; Wang, Xiaofan; Koirala, Sandhaya; Miyauchi, Yuhei; Matsuda, Kazunari

    2017-08-31

    Layered materials, such as graphene, transition metal dichalcogenides and black phosphorene, have been established rapidly as intriguing building blocks for optoelectronic devices. Here, we introduce highly polarization sensitive, broadband, and high-temperature-operation photodetectors based on multilayer germanium sulfide (GeS). The GeS photodetector shows a high photoresponsivity of about 6.8 × 10 3 A W -1 , an extremely high specific detectivity of 5.6 × 10 14 Jones, and broad spectral response in the wavelength range of 300-800 nm. More importantly, the GeS photodetector has high polarization sensitivity to incident linearly polarized light, which provides another degree of freedom for photodetectors. Tremendously enhanced photoresponsivity is observed with a temperature increase, and high responsivity is achievable at least up to 423 K. The establishment of larger photoinduced reduction of the Schottky barrier height will be significant for the investigation of the photoresponse mechanism of 2D layered material-based photodetectors. These attributes of high photocurrent generation in a wide temperature range, broad spectral response, and polarization sensitivity coupled with environmental stability indicate that the proposed GeS photodetector is very suitable for optoelectronic applications.

  17. Development of High Sensitivity Nuclear Emulsion and Fine Grained Emulsion

    Science.gov (United States)

    Kawahara, H.; Asada, T.; Naka, T.; Naganawa, N.; Kuwabara, K.; Nakamura, M.

    2014-08-01

    Nuclear emulsion is a particle detector having high spacial resolution and angular resolution. It became useful for large statistics experiment thanks to the development of automatic scanning system. In 2010, a facility for emulsion production was introduced and R&D of nuclear emulsion began at Nagoya university. In this paper, we present results of development of the high sensitivity emulsion and fine grained emulsion for dark matter search experiment. Improvement of sensitivity is achieved by raising density of silver halide crystals and doping well-adjusted amount of chemicals. Production of fine grained emulsion was difficult because of unexpected crystal condensation. By mixing polyvinyl alcohol (PVA) to gelatin as a binder, we succeeded in making a stable fine grained emulsion.

  18. Exercise tolerance in asymptomatic patients with moderate-severe valvular heart disease and preserved ejection fraction.

    Science.gov (United States)

    Olaf, Schulz; Debora, Brala; Ricarda, Bensch; Gunnar, Berghöfer; Jochen, Krämer; Schimke, Ingolf; Halle, Martin; Jaffe, Allan

    2012-12-20

    For asymptomatic patients with moderate-severe valvular heart disease, in whom symptoms may be obscured, objective exercise tolerance measures are warranted for decisions concerning physical activities and surgical treatment. We compared 61 patients (39 with aortic stenosis, 22 with aortic or mitral regurgitation) to 23 controls without valvular heart disease but with indications for stress testing. All participants underwent cardiopulmonary function testing and dobutamine stress echocardiography. Blood was drawn before as well as after bicycle stress to assess high-sensitivity cardiac troponin T (hscTnT). Patients who underwent surgery were re-evaluated 1.5 ±0.9 years after the operation. Conventional bicycle test following guideline criteria revealed a pathologic result in 26% of the patients, whereas spiroergometry showed an objectively reduced exercise tolerance in 59%, reaching a prognostically relevant feature in 39%. Stress echocardiography detected a reduced systolic reserve in 33% and elevated filling pressures in 62%. These abnormalities were significantly less present in the control group (4, 17, 9, 9, 4% respectively, p valvular heart disease beyond stress-test criteria recommended in recent guidelines. High-sensitivity cardiac troponin I may be of additional value. Results of these tests presage post-operative function.

  19. Organic dye for highly efficient solid-state dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt-Mende, L.; Bach, U.; Humphry-Baker, R.; Ito, S.; Graetzel, M. [Institut des Sciences et Ingenierie Chimiques (ISIC), Laboratoire de Photonique et Interfaces (LPI), Ecole Polytechnique Federale de Lausanne (EPFL), CH-1015 Lausanne (Switzerland); Horiuchi, T.; Miura, H. [Technology Research Laboratory, Corporate Research Center, Mitsubishi Paper Mills Limited, 46, Wadai, Tsukuba City, Ibaraki 300-4247 (Japan); Uchida, S. [Institute of Multidisciplinary Research for Advanced Materials (IMRAM), Tohoku University, 1-1 Katahira 2-chome, Aoba-ku, Sendai 980-8577 (Japan)

    2005-04-04

    The feasibility of solid-state dye-sensitized solar cells as a low-cost alternative to amorphous silicon cells is demonstrated. Such a cell with a record efficiency of over 4 % under simulated sunlight is reported, made possible by using a new organic metal-free indoline dye as the sensitizer with high absorption coefficient. (Abstract Copyright [2005], Wiley Periodicals, Inc.)

  20. Differential sensitivity of long-sleep and short-sleep mice to high doses of cocaine.

    Science.gov (United States)

    de Fiebre, C M; Ruth, J A; Collins, A C

    1989-12-01

    The cocaine sensitivity of male and female long-sleep (LS) and short-sleep (SS) mice, which have been selectively bred for differential ethanol-induced "sleep-time," was examined in a battery of behavioral and physiological tests. Differences between these two mouse lines were subtle and were seen primarily at high doses. At high doses, SS mice were more sensitive than LS mice, particularly to cocaine-induced hypothermia; however, significant hypothermia was not seen except at doses which were very near to the seizure threshold. During a 60-min test of locomotor activity, LS mice showed greater stimulation of Y-maze activity by 20 mg/kg cocaine than SS mice. Consistent with the finding of subtle differences in sensitivity to low doses of cocaine. LS and SS mice did not differ in sensitivity to cocaine inhibition of synaptosomal uptake of [3H]-dopamine, [3H]-norepinephrine or [3H]-5-hydroxytryptamine. However, consistent with the finding of differential sensitivity to high doses of cocaine, SS mice were more sensitive to the seizure-producing effects of the cocaine and lidocaine, a local anesthetic. It is hypothesized that the differential sensitivity of these mouse lines to high doses of cocaine is due to differential sensitivity to cocaine's actions on systems that regulate local anesthetic effects. Selective breeding for differential duration of alcohol-induced "sleep-time" may have resulted in differential ion channel structure or function in these mice.

  1. Characterization of a high resolution and high sensitivity pre-clinical PET scanner with 3D event reconstruction

    CERN Document Server

    Rissi, M; Bolle, E; Dorholt, O; Hines, K E; Rohne, O; Skretting, A; Stapnes, S; Volgyes, D

    2012-01-01

    COMPET is a preclinical PET scanner aiming towards a high sensitivity, a high resolution and MRI compatibility by implementing a novel detector geometry. In this approach, long scintillating LYSO crystals are used to absorb the gamma-rays. To determine the point of interaction (P01) between gamma-ray and crystal, the light exiting the crystals on one of the long sides is collected with wavelength shifters (WLS) perpendicularly arranged to the crystals. This concept has two main advantages: (1) The parallax error is reduced to a minimum and is equal for the whole field of view (FOV). (2) The P01 and its energy deposit is known in all three dimension with a high resolution, allowing for the reconstruction of Compton scattered gamma-rays. Point (1) leads to a uniform point source resolution (PSR) distribution over the whole FOV, and also allows to place the detector close to the object being imaged. Both points (1) and (2) lead to an increased sensitivity and allow for both high resolution and sensitivity at the...

  2. The Relationship between Ethical Sensitivity, High Ability and Gender in Higher Education Students

    Science.gov (United States)

    Schutte, Ingrid; Wolfensberger, Marca; Tirri, Kirsi

    2014-01-01

    This study examined the ethical sensitivity of high-ability undergraduate students (n=731) in the Netherlands who completed the 28-item Ethical Sensitivity Scale Questionnaire (ESSQ) developed by Tirri & Nokelainen (2007; 2011). The ESSQ is based on Narvaez' (2001) operationalization of ethical sensitivity in seven dimensions. The following…

  3. Development of the "Highly Sensitive Dog" questionnaire to evaluate the personality dimension "Sensory Processing Sensitivity" in dogs.

    Directory of Open Access Journals (Sweden)

    Maya Braem

    Full Text Available In humans, the personality dimension 'sensory processing sensitivity (SPS', also referred to as "high sensitivity", involves deeper processing of sensory information, which can be associated with physiological and behavioral overarousal. However, it has not been studied up to now whether this dimension also exists in other species. SPS can influence how people perceive the environment and how this affects them, thus a similar dimension in animals would be highly relevant with respect to animal welfare. We therefore explored whether SPS translates to dogs, one of the primary model species in personality research. A 32-item questionnaire to assess the "highly sensitive dog score" (HSD-s was developed based on the "highly sensitive person" (HSP questionnaire. A large-scale, international online survey was conducted, including the HSD questionnaire, as well as questions on fearfulness, neuroticism, "demographic" (e.g. dog sex, age, weight; age at adoption, etc. and "human" factors (e.g. owner age, sex, profession, communication style, etc., and the HSP questionnaire. Data were analyzed using linear mixed effect models with forward stepwise selection to test prediction of HSD-s by the above-mentioned factors, with country of residence and dog breed treated as random effects. A total of 3647 questionnaires were fully completed. HSD-, fearfulness, neuroticism and HSP-scores showed good internal consistencies, and HSD-s only moderately correlated with fearfulness and neuroticism scores, paralleling previous findings in humans. Intra- (N = 447 and inter-rater (N = 120 reliabilities were good. Demographic and human factors, including HSP score, explained only a small amount of the variance of HSD-s. A PCA analysis identified three subtraits of SPS, comparable to human findings. Overall, the measured personality dimension in dogs showed good internal consistency, partial independence from fearfulness and neuroticism, and good intra- and inter

  4. Troponin T isoform expression is modulated during Atlantic Halibut metamorphosis

    Directory of Open Access Journals (Sweden)

    Llewellyn Lynda

    2007-06-01

    Full Text Available Abstract Background Flatfish metamorphosis is a thyroid hormone (TH driven process which leads to a dramatic change from a symmetrical larva to an asymmetrical juvenile. The effect of THs on muscle and in particular muscle sarcomer protein genes is largely unexplored in fish. The change in Troponin T (TnT, a pivotal protein in the assembly of skeletal muscles sarcomeres and a modulator of calcium driven muscle contraction, during flatfish metamophosis is studied. Results In the present study five cDNAs for halibut TnT genes were cloned; three were splice variants arising from a single fast TnT (fTnT gene; a fourth encoded a novel teleost specific fTnT-like cDNA (AfTnT expressed exclusively in slow muscle and the fifth encoded the teleost specific sTnT2. THs modified the expression of halibut fTnT isoforms which changed from predominantly basic to acidic isoforms during natural and T4 induced metamorphosis. In contrast, expression of red muscle specific genes, AfTnT and sTnT2, did not change during natural metamorphosis or after T4 treatment. Prior to and after metamorphosis no change in the dorso-ventral symmetry or temporal-spatial expression pattern of TnT genes and muscle fibre organization occurred in halibut musculature. Conclusion Muscle organisation in halibut remains symmetrical even after metamorphosis suggesting TH driven changes are associated with molecular adaptations. We hypothesize that species specific differences in TnT gene expression in teleosts underlies different larval muscle developmental programs which better adapts them to the specific ecological constraints.

  5. Towards highly sensitive strain sensing based on nanostructured materials

    International Nuclear Information System (INIS)

    Dao, Dzung Viet; Nakamura, Koichi; Sugiyama, Susumu; Bui, Tung Thanh; Dau, Van Thanh; Yamada, Takeo; Hata, Kenji

    2010-01-01

    This paper presents our recent theoretical and experimental study of piezo-effects in nanostructured materials for highly sensitive, high resolution mechanical sensors. The piezo-effects presented here include the piezoresistive effect in a silicon nanowire (SiNW) and single wall carbon nanotube (SWCNT) thin film, as well as the piezo-optic effect in a Si photonic crystal (PhC) nanocavity. Firstly, the electronic energy band structure of the silicon nanostructure is discussed and simulated by using the First-Principles Calculations method. The result showed a remarkably different energy band structure compared with that of bulk silicon. This difference in the electronic state will result in different physical, chemical, and therefore, sensing properties of silicon nanostructures. The piezoresistive effects of SiNW and SWCNT thin film were investigated experimentally. We found that, when the width of ( 110 ) p-type SiNW decreases from 500 to 35 nm, the piezoresistive effect increases by more than 60%. The longitudinal piezoresistive coefficient of SWCNT thin film was measured to be twice that of bulk p-type silicon. Finally, theoretical investigations of the piezo-optic effect in a PhC nanocavity based on Finite Difference Time Domain (FDTD) showed extremely high resolution strain sensing. These nanostructures were fabricated based on top-down nanofabrication technology. The achievements of this work are significant for highly sensitive, high resolution and miniaturized mechanical sensors

  6. High-sensitivity bend angle measurements using optical fiber gratings.

    Science.gov (United States)

    Rauf, Abdul; Zhao, Jianlin; Jiang, Biqiang

    2013-07-20

    We present a high-sensitivity and more flexible bend measurement method, which is based on the coupling of core mode to the cladding modes at the bending region in concatenation with optical fiber grating serving as band reflector. The characteristics of a bend sensing arm composed of bending region and optical fiber grating is examined for different configurations including single fiber Bragg grating (FBG), chirped FBG (CFBG), and double FBGs. The bend loss curves for coated, stripped, and etched sections of fiber in the bending region with FBG, CFBG, and double FBG are obtained experimentally. The effect of separation between bending region and optical fiber grating on loss is measured. The loss responses for single FBG and CFBG configurations are compared to discover the effectiveness for practical applications. It is demonstrated that the sensitivity of the double FBG scheme is twice that of the single FBG and CFBG configurations, and hence acts as sensitivity multiplier. The bend loss response for different fiber diameters obtained through etching in 40% hydrofluoric acid, is measured in double FBG scheme that resulted in a significant increase in the sensitivity, and reduction of dead-zone.

  7. High Temperature and High Sensitive NOx Gas Sensor with Hetero-Junction Structure using Laser Ablation Method

    Science.gov (United States)

    Gao, Wei; Shi, Liqin; Hasegawa, Yuki; Katsube, Teruaki

    In order to develop a high temperature (200°C˜400°C) and high sensitive NOx gas sensor, we developed a new structure of SiC-based hetero-junction device Pt/SnO2/SiC/Ni, Pt/In2O3/SiC/Ni and Pt/WO3/SiC/Ni using a laser ablation method for the preparation of both metal (Pt) electrode and metal-oxide film. It was found that Pt/In2O3/SiC/Ni sensor shows higher sensitivity to NO2 gas compared with the Pt/SnO2/SiC/Ni and Pt/WO3/SiC/Ni sensor, whereas the Pt/WO3/SiC/Ni sensor had better sensitivity to NO gas. These results suggest that selective detection of NO and NO2 gases may be obtained by choosing different metal oxide films.

  8. Development of High Sensitivity Nuclear Emulsion and Fine Grained Emulsion

    International Nuclear Information System (INIS)

    Kawahara, H.; Asada, T.; Naka, T.; Naganawa, N.; Kuwabara, K.; Nakamura, M.

    2014-01-01

    Nuclear emulsion is a particle detector having high spacial resolution and angular resolution. It became useful for large statistics experiment thanks to the development of automatic scanning system. In 2010, a facility for emulsion production was introduced and R and D of nuclear emulsion began at Nagoya university. In this paper, we present results of development of the high sensitivity emulsion and fine grained emulsion for dark matter search experiment. Improvement of sensitivity is achieved by raising density of silver halide crystals and doping well-adjusted amount of chemicals. Production of fine grained emulsion was difficult because of unexpected crystal condensation. By mixing polyvinyl alcohol (PVA) to gelatin as a binder, we succeeded in making a stable fine grained emulsion

  9. Time-dependent responses of rat troponin I and cardiac injury following isoproterenol administration

    Directory of Open Access Journals (Sweden)

    Sabaheta Hasić

    2011-02-01

    Full Text Available Aim To develop a rat model of myocardial infarction induced by isoproterenol (ISO. We investigated a type of histological myocardial changes and cardiac troponin I (TnI kinetic. Methods The study has used adult, male, Wistar strain rats. Rats were distributed in ISO and control groups. Rats treated with ISO were divided into groups according to the time of cTnI and myocardial lesion analyses: ISO I (30’, ISO II (60’, ISO III (120’ and ISO IV (240’. We determined cTnI (Life Diagnostics Inc. West Chester PA, USA in the serum by ELISA method. We performed histological analysis on the specimens of left ventricular wall stained by hematoxillin-eosin (HE method. Results The irst statistically signiicant rise of cTnI was noted 30 minutes after the ISO administration. There was no statistically signiicant difference between cTnI mean values among the ISO groups. Observed myocardial histological changes were time dependent. Conclusions This model can be suitable for cardioprotective and cardiotoxicity supstance investigations followed by cTnI measurement in blood. The similarity between induced myocardial lesion on animal model in our study and human myocardial lesion in ischemia give us suficient impulse for further preclinical researches of new cardiac markers.

  10. High pressure-sensitive gene expression in Lactobacillus sanfranciscensis

    Directory of Open Access Journals (Sweden)

    R.F. Vogel

    2005-08-01

    Full Text Available Lactobacillus sanfranciscensis is a Gram-positive lactic acid bacterium used in food biotechnology. It is necessary to investigate many aspects of a model organism to elucidate mechanisms of stress response, to facilitate preparation, application and performance in food fermentation, to understand mechanisms of inactivation, and to identify novel tools for high pressure biotechnology. To investigate the mechanisms of the complex bacterial response to high pressure we have analyzed changes in the proteome and transcriptome by 2-D electrophoresis, and by microarrays and real time PCR, respectively. More than 16 proteins were found to be differentially expressed upon high pressure stress and were compared to those sensitive to other stresses. Except for one apparently high pressure-specific stress protein, no pressure-specific stress proteins were found, and the proteome response to pressure was found to differ from that induced by other stresses. Selected pressure-sensitive proteins were partially sequenced and their genes were identified by reverse genetics. In a transcriptome analysis of a redundancy cleared shot gun library, about 7% of the genes investigated were found to be affected. Most of them appeared to be up-regulated 2- to 4-fold and these results were confirmed by real time PCR. Gene induction was shown for some genes up-regulated at the proteome level (clpL/groEL/rbsK, while the response of others to high hydrostatic pressure at the transcriptome level seemed to differ from that observed at the proteome level. The up-regulation of selected genes supports the view that the cell tries to compensate for pressure-induced impairment of translation and membrane transport.

  11. New approach to 3-D, high sensitivity, high mass resolution space plasma composition measurements

    International Nuclear Information System (INIS)

    McComas, D.J.; Nordholt, J.E.

    1990-01-01

    This paper describes a new type of 3-D space plasma composition analyzer. The design combines high sensitivity, high mass resolution measurements with somewhat lower mass resolution but even higher sensitivity measurements in a single compact and robust design. While the lower resolution plasma measurements are achieved using conventional straight-through time-of-flight mass spectrometry, the high mass resolution measurements are made by timing ions reflected in a linear electric field (LEF), where the restoring force that an ion experiences is proportional to the depth it travels into the LEF region. Consequently, the ion's equation of motion in that dimension is that of a simple harmonic oscillator and its travel time is simply proportional to the square root of the ion's mass/charge (m/q). While in an ideal LEF, the m/q resolution can be arbitrarily high, in a real device the resolution is limited by the field linearity which can be achieved. In this paper we describe how a nearly linear field can be produced and discuss how the design can be optimized for various different plasma regimes and spacecraft configurations

  12. A CMOS In-Pixel CTIA High Sensitivity Fluorescence Imager.

    Science.gov (United States)

    Murari, Kartikeya; Etienne-Cummings, Ralph; Thakor, Nitish; Cauwenberghs, Gert

    2011-10-01

    Traditionally, charge coupled device (CCD) based image sensors have held sway over the field of biomedical imaging. Complementary metal oxide semiconductor (CMOS) based imagers so far lack sensitivity leading to poor low-light imaging. Certain applications including our work on animal-mountable systems for imaging in awake and unrestrained rodents require the high sensitivity and image quality of CCDs and the low power consumption, flexibility and compactness of CMOS imagers. We present a 132×124 high sensitivity imager array with a 20.1 μm pixel pitch fabricated in a standard 0.5 μ CMOS process. The chip incorporates n-well/p-sub photodiodes, capacitive transimpedance amplifier (CTIA) based in-pixel amplification, pixel scanners and delta differencing circuits. The 5-transistor all-nMOS pixel interfaces with peripheral pMOS transistors for column-parallel CTIA. At 70 fps, the array has a minimum detectable signal of 4 nW/cm(2) at a wavelength of 450 nm while consuming 718 μA from a 3.3 V supply. Peak signal to noise ratio (SNR) was 44 dB at an incident intensity of 1 μW/cm(2). Implementing 4×4 binning allowed the frame rate to be increased to 675 fps. Alternately, sensitivity could be increased to detect about 0.8 nW/cm(2) while maintaining 70 fps. The chip was used to image single cell fluorescence at 28 fps with an average SNR of 32 dB. For comparison, a cooled CCD camera imaged the same cell at 20 fps with an average SNR of 33.2 dB under the same illumination while consuming over a watt.

  13. High order effects in cross section sensitivity analysis

    International Nuclear Information System (INIS)

    Greenspan, E.; Karni, Y.; Gilai, D.

    1978-01-01

    Two types of high order effects associated with perturbations in the flux shape are considered: Spectral Fine Structure Effects (SFSE) and non-linearity between changes in performance parameters and data uncertainties. SFSE are investigated in Part I using a simple single resonance model. Results obtained for each of the resolved and for representative unresolved resonances of 238 U in a ZPR-6/7 like environment indicate that SFSE can have a significant contribution to the sensitivity of group constants to resonance parameters. Methods to account for SFSE both for the propagation of uncertainties and for the adjustment of nuclear data are discussed. A Second Order Sensitivity Theory (SOST) is presented, and its accuracy relative to that of the first order sensitivity theory and of the direct substitution method is investigated in Part II. The investigation is done for the non-linear problem of the effect of changes in the 297 keV sodium minimum cross section on the transport of neutrons in a deep-penetration problem. It is found that the SOST provides a satisfactory accuracy for cross section uncertainty analysis. For the same degree of accuracy, the SOST can be significantly more efficient than the direct substitution method

  14. N-terminal pro-brain natriuretic peptide for additional risk stratification in patients with non-ST-elevation acute coronary syndrome and an elevated troponin T: an Invasive versus Conservative Treatment in Unstable coronary Syndromes (ICTUS) substudy

    NARCIS (Netherlands)

    Windhausen, Fons; Hirsch, Alexander; Sanders, Gerard T.; Cornel, Jan Hein; Fischer, Johan; van Straalen, Jan P.; Tijssen, Jan G. P.; Verheugt, Freek W. A.; de Winter, Robbert J.

    2007-01-01

    BACKGROUND: New evidence has emerged that the assessment of multiple biomarkers such as cardiac troponin T (cTnT) and N-terminal pro-brain natriuretic peptide (NT-proBNP) in patients with non-ST-elevation acute coronary syndrome (nSTE-ACS) provides unique prognostic information. The purpose of this

  15. High-Sensitivity Temperature-Independent Silicon Photonic Microfluidic Biosensors

    Science.gov (United States)

    Kim, Kangbaek

    Optical biosensors that can precisely quantify the presence of specific molecular species in real time without the need for labeling have seen increased use in the drug discovery industry and molecular biology in general. Of the many possible optical biosensors, the TM mode Si biosensor is shown to be very attractive in the sensing application because of large field amplitude on the surface and cost effective CMOS VLSI fabrication. Noise is the most fundamental factor that limits the performance of sensors in development of high-sensitivity biosensors, and noise reduction techniques require precise studies and analysis. One such example stems from thermal fluctuations. Generally SOI biosensors are vulnerable to ambient temperature fluctuations because of large thermo-optic coefficient of silicon (˜2x10 -4 RIU/K), typically requiring another reference ring and readout sequence to compensate temperature induced noise. To address this problem, we designed sensors with a novel TM-mode shallow-ridge waveguide that provides both large surface amplitude for bulk and surface sensing. With proper design, this also provides large optical confinement in the aqueous cladding that renders the device athermal using the negative thermo-optic coefficient of water (~ --1x10-4RIU/K), demonstrating cancellation of thermo-optic effects for aqueous solution operation near 300K. Additional limitations resulting from mechanical actuator fluctuations, stability of tunable lasers, and large 1/f noise of lasers and sensor electronics can limit biosensor performance. Here we also present a simple harmonic feedback readout technique that obviates the need for spectrometers and tunable lasers. This feedback technique reduces the impact of 1/f noise to enable high-sensitivity, and a DSP lock-in with 256 kHz sampling rate can provide down to micros time scale monitoring for fast transitions in biomolecular concentration with potential for small volume and low cost. In this dissertation, a novel

  16. A highly sensitive CMOS digital Hall sensor for low magnetic field applications.

    Science.gov (United States)

    Xu, Yue; Pan, Hong-Bin; He, Shu-Zhuan; Li, Li

    2012-01-01

    Integrated CMOS Hall sensors have been widely used to measure magnetic fields. However, they are difficult to work with in a low magnetic field environment due to their low sensitivity and large offset. This paper describes a highly sensitive digital Hall sensor fabricated in 0.18 μm high voltage CMOS technology for low field applications. The sensor consists of a switched cross-shaped Hall plate and a novel signal conditioner. It effectively eliminates offset and low frequency 1/f noise by applying a dynamic quadrature offset cancellation technique. The measured results show the optimal Hall plate achieves a high current related sensitivity of about 310 V/AT. The whole sensor has a remarkable ability to measure a minimum ± 2 mT magnetic field and output a digital Hall signal in a wide temperature range from -40 °C to 120 °C.

  17. From Molecular Design to Co-sensitization; High performance indole based photosensitizers for dye-sensitized solar cells

    International Nuclear Information System (INIS)

    Babu, Dickson D.; Su, Rui; El-Shafei, Ahmed; Adhikari, Airody Vasudeva

    2016-01-01

    displays promising photovoltaic results and exhibited an enhanced efficiency of 8.06%. Further, good agreement between the calculated and experimental results showcase the precision of the energy functional and basis set utilized in this study. All these findings provide a deeper insight and better understanding into the intricacies involved in the design of superior co-sensitizers for development of highly efficient DSSCs.

  18. High degree gravitational sensitivity from Mars orbiters for the GMM-1 gravity model

    Science.gov (United States)

    Lerch, F. J.; Smith, D. E.; Chan, J. C.; Patel, G. B.; Chinn, D. S.

    1994-01-01

    Orbital sensitivity of the gravity field for high degree terms (greater than 30) is analyzed on satellites employed in a Goddard Mars Model GMM-1, complete in spherical harmonics through degree and order 50. The model is obtained from S-band Doppler data on Mariner 9 (M9), Viking Orbiter 1 (VO1), and Viking Orbiter 2 (VO2) spacecraft, which were tracked by the NASA Deep Space Network on seven different highly eccentric orbits. The main sensitivity of the high degree terms is obtained from the VO1 and VO2 low orbits (300 km periapsis altitude), where significant spectral sensitivity is seen for all degrees out through degree 50. The velocity perturbations show a dominant effect at periapsis and significant effects out beyond the semi-latus rectum covering over 180 degrees of the orbital groundtrack for the low altitude orbits. Because of the wideband of periapsis motion covering nearly 180 degrees in w and +39 degrees in latitude coverage, the VO1 300 km periapsis altitude orbit with inclination of 39 degrees gave the dominant sensitivity in the GMM-1 solution for the high degree terms. Although the VO2 low periapsis orbit has a smaller band of periapsis mapping coverage, it strongly complements the VO1 orbit sensitivity for the GMM-1 solution with Doppler tracking coverage over a different inclination of 80 degrees.

  19. Photon Counting System for High-Sensitivity Detection of Bioluminescence at Optical Fiber End.

    Science.gov (United States)

    Iinuma, Masataka; Kadoya, Yutaka; Kuroda, Akio

    2016-01-01

    The technique of photon counting is widely used for various fields and also applicable to a high-sensitivity detection of luminescence. Thanks to recent development of single photon detectors with avalanche photodiodes (APDs), the photon counting system with an optical fiber has become powerful for a detection of bioluminescence at an optical fiber end, because it allows us to fully use the merits of compactness, simple operation, highly quantum efficiency of the APD detectors. This optical fiber-based system also has a possibility of improving the sensitivity to a local detection of Adenosine triphosphate (ATP) by high-sensitivity detection of the bioluminescence. In this chapter, we are introducing a basic concept of the optical fiber-based system and explaining how to construct and use this system.

  20. CALDER: High-sensitivity cryogenic light detectors

    International Nuclear Information System (INIS)

    Casali, N.; Bellini, F.; Cardani, L.

    2017-01-01

    The current bolometric experiments searching for rare processes such as neutrinoless double-beta decay or dark matter interaction demand for cryogenic light detectors with high sensitivity, large active area and excellent scalability and radio-purity in order to reduce their background budget. The CALDER project aims to develop such kind of light detectors implementing phonon-mediated Kinetic Inductance Detectors (KIDs). The goal for this project is the realization of a 5 × 5 cm"2 light detector working between 10 and 100mK with a baseline resolution RMS below 20 eV. In this work the characteristics and the performances of the prototype detectors developed in the first project phase will be shown.

  1. Evaluation of plasma sphingosine 1-phosphate, hepcidin and cardiovascular damage biomarkers (cardiac troponin I and homocysteine) in rats infected with brucellosis and vaccinated (Rev-1, RB-51).

    Science.gov (United States)

    Azimzadeh, Kaveh; Nasrollahi Nargesabad, Reza; Vousooghi, Nasim

    2017-08-01

    Brucellosis is known as one of important zoonosis. Studying the histological and biochemical effects of the disease could help to increase our knowledge about it. The aim of the present study was to evaluate changes of plasma parameters after intraperitoneal injection of two species of Brucella (Brucella melitensis and Brucella abortus) and two vaccines (Rev-1, RB-51) in the rat. Forty male rats were divided into five groups (n = 8 in each group). Two groups received suspensions of Brucella abortus and Brucella melitensis and two other groups were injected intraperitoneally with two mentioned vaccines and the last group received only distilled water. The results showed a significant increase in sphingosine 1-phosphate, Malondialdehyde, hepcidin, homocysteine, cardiac troponin I and copper levels and a considerable decrease in the levels of iron and zinc (P ≤ 0.01) in infected groups compared to the control animals. In vaccinated groups, hepcidin was increased but other parameters were not changed in comparison to the control group. It can be concluded that increase of homocysteine and cardiac troponin I in brucellosis could be a warning for cardiac adverse effects. Besides, increase of sphingosine 1-phosphate probably indicates its stimulant and modulatory effects in anti- Brucellosis biochemical pathways of the host. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Polymer-Particle Pressure-Sensitive Paint with High Photostability

    Directory of Open Access Journals (Sweden)

    Yu Matsuda

    2016-04-01

    Full Text Available We propose a novel fast-responding and paintable pressure-sensitive paint (PSP based on polymer particles, i.e. polymer-particle (pp-PSP. As a fast-responding PSP, polymer-ceramic (PC-PSP is widely studied. Since PC-PSP generally consists of titanium (IV oxide (TiO2 particles, a large reduction in the luminescent intensity will occur due to the photocatalytic action of TiO2. We propose the usage of polymer particles instead of TiO2 particles to prevent the reduction in the luminescent intensity. Here, we fabricate pp-PSP based on the polystyrene particle with a diameter of 1 μm, and investigate the pressure- and temperature-sensitives, the response time, and the photostability. The performances of pp-PSP are compared with those of PC-PSP, indicating the high photostability with the other characteristics comparable to PC-PSP.

  3. Association of elevated serum cardiac troponin-I level and complications in acute heart failurecases

    Directory of Open Access Journals (Sweden)

    Farjana Akhter

    2013-07-01

    Full Text Available Acute heart failure is one of the major causes of morbidity and mortality all over the world. Available published data has suggested that patients of acute heart failure with elevated level of serum cardiac troponin-I (cTn-I have more adverse outcomes than that of acute heart failure with normal cTn-I level. Elevated level of serum cTn-I is a potential risk factor for acute heart failure. This study was carried out in the department of Biochemistry, Dhaka Medical College and National Institute of Cardiovascular Disease (NICVD during the period from January 2010 to December 2010. In this study, 100 patients with acute heart failure were enrolled. Out of 100 cases, 50 had elevated serum cTn-I (cTn-I ³ 1.0 ng/ml and 50 had normal serum cTn-I (cTn-I < 1.0 ng/ml. The adverse outcome of the two groups were recorded and compared. Patients with high and normal serum cTn-I had mean age of 52.40 ± 8.10 years and 54.64 ± 7.26 years respectively while male and female cases were equally distributed. Left ventricular systolic dysfunction (lower ejection fraction was significantly (p<0.05 higher among cases with elevated cTn-I level compared to those with normal level. The rate of renal failure (raised serum creatinine, impaired liver functions (raised ALT and AST and abnormal serum electrolytes were significantly higher among the patients with elevated cTn-I compared to those with normal level. The study showed that elevated serum cTn-I level was a good biomarker to indicate adverse complications in acute heart failure cases. Ibrahim Med. Coll. J. 2013; 7(2: 32-34

  4. Instruction manual for ORNL tandem high abundance sensitivity mass spectrometer

    International Nuclear Information System (INIS)

    Smith, D.H.; McKown, H.S.; Chrisite, W.H.; Walker, R.L.; Carter, J.A.

    1976-06-01

    This manual describes the physical characteristics of the tandem mass spectrometer built by Oak Ridge National Laboratory for the International Atomic Energy Agency. Specific requirements met include ability to run small samples, high abundance sensitivity, good precision and accuracy, and adequate sample throughput. The instrument is capable of running uranium samples as small as 10 -12 g and has an abundance sensitivity in excess of 10 6 . Precision and accuracy are enhanced by a special sweep control circuit. Sample throughput is 6 to 12 samples per day. Operating instructions are also given

  5. Spectral and Concentration Sensitivity of Multijunction Solar Cells at High Temperature: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, Daniel J.; Steiner, Myles A.; Perl, Emmett E.; Simon, John

    2017-06-14

    We model the performance of two-junction solar cells at very high temperatures of ~400 degrees C and beyond for applications such as hybrid PV/solar-thermal power production, and identify areas in which the design and performance characteristics behave significantly differently than at more conventional near-room-temperature operating conditions. We show that high-temperature operation reduces the sensitivity of the cell efficiency to spectral content, but increases the sensitivity to concentration, both of which have implications for energy yield in terrestrial PV applications. For other high-temperature applications such as near-sun space missions, our findings indicate that concentration may be a useful tool to enhance cell efficiency.

  6. New and highly sensitive assay for L-5-hydroxytryptophan decarboxylase activity by high-performance liquid chromatography-voltammetry.

    Science.gov (United States)

    Rahman, M K; Nagatsu, T; Kato, T

    1980-12-12

    This paper describes a new, inexpensive and highly sensitive assay for aromatic L-amino acid decarboxylase (AADC) activity, using L-5-hydroxytryptophan (L-5-HTP) as substrate, in rat and human brains and serum by high-performance liquid chromatography (HPLC) with voltammetric detection. L-5-HTP was used as substrate and D-5-HTP for the blank. After isolating serotonin (5-HT) formed enzymatically from L-5-HTP on a small Amberlite CG-50 column, the 5-HT was eluted with hydrochloric acid and assayed by HPLC with a voltammetric detector. N-Methyldopamine was added to each incubation mixture as an internal standard. This method is sensitive enough to measure 5-HT, formed by the enzyme, 100 fmol to 140 pmol or more. An advantage of this method is that one can incubate the enzyme for longer time (up to 150 min), as compared with AADC assay using L-DOPA as substrate, resulting in a very high sensitivity. By using this new method, AADC activity was discovered in rat serum.

  7. High sensitivity probe absorption technique for time-of-flight ...

    Indian Academy of Sciences (India)

    Abstract. We report on a phase-sensitive probe absorption technique with high sen- sitivity, capable of detecting a few hundred ultra-cold atoms in flight in an observation time of a few milliseconds. The large signal-to-noise ratio achieved is sufficient for reliable measurements on low intensity beams of cold atoms.

  8. Nitrogen detected TROSY at high field yields high resolution and sensitivity for protein NMR

    International Nuclear Information System (INIS)

    Takeuchi, Koh; Arthanari, Haribabu; Shimada, Ichio; Wagner, Gerhard

    2015-01-01

    Detection of 15 N in multidimensional NMR experiments of proteins has sparsely been utilized because of the low gyromagnetic ratio (γ) of nitrogen and the presumed low sensitivity of such experiments. Here we show that selecting the TROSY components of proton-attached 15 N nuclei (TROSY 15 N H ) yields high quality spectra in high field magnets (>600 MHz) by taking advantage of the slow 15 N transverse relaxation and compensating for the inherently low 15 N sensitivity. The 15 N TROSY transverse relaxation rates increase modestly with molecular weight but the TROSY gain in peak heights depends strongly on the magnetic field strength. Theoretical simulations predict that the narrowest line width for the TROSY 15 N H component can be obtained at 900 MHz, but sensitivity reaches its maximum around 1.2 GHz. Based on these considerations, a 15 N-detected 2D 1 H– 15 N TROSY-HSQC ( 15 N-detected TROSY-HSQC) experiment was developed and high-quality 2D spectra were recorded at 800 MHz in 2 h for 1 mM maltose-binding protein at 278 K (τ c  ∼ 40 ns). Unlike for 1 H detected TROSY, deuteration is not mandatory to benefit 15 N detected TROSY due to reduced dipolar broadening, which facilitates studies of proteins that cannot be deuterated, especially in cases where production requires eukaryotic expression systems. The option of recording 15 N TROSY of proteins expressed in H 2 O media also alleviates the problem of incomplete amide proton back exchange, which often hampers the detection of amide groups in the core of large molecular weight proteins that are expressed in D 2 O culture media and cannot be refolded for amide back exchange. These results illustrate the potential of 15 N H -detected TROSY experiments as a means to exploit the high resolution offered by high field magnets near and above 1 GHz

  9. A highly sensitive RF-to-DC power converter with an extended dynamic range

    KAUST Repository

    Almansouri, Abdullah Saud Mohammed

    2017-10-24

    This paper proposes a highly sensitive RF-to-DC power converter with an extended dynamic range that is designed to operate at the medical band 433 MHz and simulated using 0.18 μm CMOS technology. Compared to the conventional fully cross-coupled rectifier, the proposed design offers 3.2× the dynamic range. It is also highly sensitive and requires −18 dBm of input power to produce a 1 V-output voltage when operating with a 100 kΩ load. Furthermore, the proposed design offers an open circuit sensitivity of −23.4 dBm and a peak power conversion efficiency of 67%.

  10. Real-time, single-step bioassay using nanoplasmonic resonator with ultra-high sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiang; Ellman, Jonathan A; Chen, Fanqing Frank; Su, Kai-Hang; Wei, Qi-Huo; Sun, Cheng

    2014-04-01

    A nanoplasmonic resonator (NPR) comprising a metallic nanodisk with alternating shielding layer(s), having a tagged biomolecule conjugated or tethered to the surface of the nanoplasmonic resonator for highly sensitive measurement of enzymatic activity. NPRs enhance Raman signals in a highly reproducible manner, enabling fast detection of protease and enzyme activity, such as Prostate Specific Antigen (paPSA), in real-time, at picomolar sensitivity levels. Experiments on extracellular fluid (ECF) from paPSA-positive cells demonstrate specific detection in a complex bio-fluid background in real-time single-step detection in very small sample volumes.

  11. Performance of high-resolution position-sensitive detectors developed for storage-ring decay experiments

    International Nuclear Information System (INIS)

    Yamaguchi, T.; Suzaki, F.; Izumikawa, T.; Miyazawa, S.; Morimoto, K.; Suzuki, T.; Tokanai, F.; Furuki, H.; Ichihashi, N.; Ichikawa, C.; Kitagawa, A.; Kuboki, T.; Momota, S.; Nagae, D.; Nagashima, M.; Nakamura, Y.; Nishikiori, R.; Niwa, T.; Ohtsubo, T.; Ozawa, A.

    2013-01-01

    Highlights: • Position-sensitive detectors were developed for storage-ring decay spectroscopy. • Fiber scintillation and silicon strip detectors were tested with heavy ion beams. • A new fiber scintillation detector showed an excellent position resolution. • Position and energy detection by silicon strip detectors enable full identification. -- Abstract: As next generation spectroscopic tools, heavy-ion cooler storage rings will be a unique application of highly charged RI beam experiments. Decay spectroscopy of highly charged rare isotopes provides us important information relevant to the stellar conditions, such as for the s- and r-process nucleosynthesis. In-ring decay products of highly charged RI will be momentum-analyzed and reach a position-sensitive detector set-up located outside of the storage orbit. To realize such in-ring decay experiments, we have developed and tested two types of high-resolution position-sensitive detectors: silicon strips and scintillating fibers. The beam test experiments resulted in excellent position resolutions for both detectors, which will be available for future storage-ring experiments

  12. High hunger state increases olfactory sensitivity to neutral but not food odors.

    Science.gov (United States)

    Stafford, Lorenzo D; Welbeck, Kimberley

    2011-01-01

    Understanding how hunger state relates to olfactory sensitivity has become more urgent due to their possible role in obesity. In 2 studies (within-subjects: n = 24, between-subjects: n = 40), participants were provided with lunch before (satiated state) or after (nonsatiated state) testing and completed a standardized olfactory threshold test to a neutral odor (Experiments 1 and 2) and discrimination test to a food odor (Experiment 2). Experiment 1 revealed that olfactory sensitivity was greater in the nonsatiated versus satiated state, with additionally increased sensitivity for the low body mass index (BMI) compared with high BMI group. Experiment 2 replicated this effect for neutral odors, but in the case of food odors, those in a satiated state had greater acuity. Additionally, whereas the high BMI group had higher acuity to food odors in the satiated versus nonsatiated state, no such differences were found for the low BMI group. The research here is the first to demonstrate how olfactory acuity changes as a function of hunger state and relatedness of odor to food and that BMI can predict differences in olfactory sensitivity.

  13. Highly Sensitive and Selective Gas Sensor Using Hydrophilic and Hydrophobic Graphenes

    Science.gov (United States)

    Some, Surajit; Xu, Yang; Kim, Youngmin; Yoon, Yeoheung; Qin, Hongyi; Kulkarni, Atul; Kim, Taesung; Lee, Hyoyoung

    2013-01-01

    New hydrophilic 2D graphene oxide (GO) nanosheets with various oxygen functional groups were employed to maintain high sensitivity in highly unfavorable environments (extremely high humidity, strong acidic or basic). Novel one-headed polymer optical fiber sensor arrays using hydrophilic GO and hydrophobic reduced graphene oxide (rGO) were carefully designed, leading to the selective sensing of volatile organic gases for the first time. The two physically different surfaces of GO and rGO could provide the sensing ability to distinguish between tetrahydrofuran (THF) and dichloromethane (MC), respectively, which is the most challenging issue in the area of gas sensors. The eco-friendly physical properties of GO allowed for faster sensing and higher sensitivity when compared to previous results for rGO even under extreme environments of over 90% humidity, making it the best choice for an environmentally friendly gas sensor. PMID:23736838

  14. Applications of molecules as high-resolution, high-sensitivity threshold electron detectors

    International Nuclear Information System (INIS)

    Chutjian, A.

    1991-01-01

    The goal of the work under the contract entitled ''Applications of Molecules as High-Resolution, High-Sensitivity Threshold Electron Detectors'' (DoE IAA No. DE-AI01-83ER13093 Mod. A006) was to explore the electron attachment properties of a variety of molecules at electron energies not accessible by other experimental techniques. As a result of this work, not only was a large body of basic data measured on attachment cross sections and rate constants; but also extensive theoretical calculations were carried out to verify the underlying phenomenon of s-wave attachment. Important outgrowths of this week were also realized in other areas of research. The basic data have applications in fields such as combustion, soot reduction, rocket-exhaust modification, threshold photoelectron spectroscopy, and trace species detection

  15. Cardiac biomarkers in neonatal hypoxic ischaemia.

    LENUS (Irish Health Repository)

    Sweetman, D

    2012-04-01

    Following a perinatal hypoxic-ischaemic insult, term infants commonly develop cardiovascular dysfunction. Troponin-T, troponin-I and brain natriuretic peptide are sensitive indicators of myocardial compromise. The long-term effects of cardiovascular dysfunction on neurodevelopmental outcome following perinatal hypoxic ischaemia remain controversial. Follow-up studies are warranted to ensure optimal cardiac function in adulthood. CONCLUSION: Cardiac biomarkers may improve the diagnosis of myocardial injury, help guide management, estimate mortality risk and may also aid in longterm neurodevelopmental outcome prediction following neonatal hypoxic-ischaemia.

  16. Highly sensitive electrochemical determination of 1-naphthol based on high-index facet SnO2 modified electrode

    International Nuclear Information System (INIS)

    Huang Xiaofeng; Zhao Guohua; Liu Meichuan; Li Fengting; Qiao Junlian; Zhao Sichen

    2012-01-01

    Highlights: ► It is the first time to employ high-index faceted SnO 2 in electrochemical analysis. ► High-index faceted SnO 2 has excellent electrochemical activity toward 1-naphthol. ► Highly sensitive determination of 1-naphthol is realized on high-index faceted SnO 2 . ► The detection limit of 1-naphthol is as low as 5 nM on high-index faceted SnO 2 . ► Electro-oxidation kinetics for 1-napthol on the novel electrode is discussed. - Abstract: SnO 2 nanooctahedron with {2 2 1} high-index facet (HIF) was synthesized by a simple hydrothermal method, and was firstly employed to sensitive electrochemical sensing of a typical organic pollutant, 1-naphthol (1-NAP). The constructed HIF SnO 2 modified glassy carbon electrode (HIF SnO 2 /GCE) possessed advantages of large effective electrode area, high electron transfer rate, and low charge transfer resistance. These improved electrochemical properties allowed the high electrocatalytic performance, high effective active sites and high adsorption capacity of 1-NAP on HIF SnO 2 /GCE. Cyclic voltammetry (CV) results showed that the electrochemical oxidation of 1-NAP obeyed a two-electron transfer process and the electrode reaction was under diffusion control on HIF SnO 2 /GCE. By adopting differential pulse voltammetry (DPV), electrochemical detection of 1-NAP was conducted on HIF SnO 2 /GCE with a limit of detection as low as 5 nM, which was relatively low compared to the literatures. The electrode also illustrated good stability in comparison with those reported value. Satisfactory results were obtained with average recoveries in the range of 99.7–103.6% in the real water sample detection. A promising device for the electrochemical detection of 1-NAP with high sensitivity has therefore been provided.

  17. High Sensitivity Indium Phosphide Based Avalanche Photodiode Focal Plane Arrays, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — nLight has demonstrated highly-uniform APD arrays based on the highly sensitive InGaAs/InP material system. These results provide great promise for achieving the...

  18. Eating high fat chow increases the sensitivity of rats to 8-OH-DPAT-induced lower lip retraction.

    Science.gov (United States)

    Li, Jun-Xu; Ju, Shutian; Baladi, Michelle G; Koek, Wouter; France, Charles P

    2011-12-01

    Eating high fat food can alter sensitivity to drugs acting on dopamine systems; this study examined whether eating high fat food alters sensitivity to a drug acting on serotonin (5-HT) systems. Sensitivity to (+)-8-hydroxy-2-(dipropylamino) tetralin hydrobromide (8-OH-DPAT; 5-HT1A receptor agonist)-induced lower lip retraction was examined in separate groups (n=8-9) of rats with free access to standard (5.7% fat) or high fat (34.3% fat) chow; sensitivity to quinpirole (dopamine D3/D2 receptor agonist)-induced yawning was also examined. Rats eating high fat chow gained more body weight than rats eating standard chow and, after 6 weeks of eating high fat chow, they were more sensitive to 8-OH-DPAT (0.01-0.1 mg/kg)-induced lower lip retraction and quinpirole (0.0032-0.32 mg/kg)-induced yawning. These changes were not reversed when rats that previously ate high fat chow were switched to eating standard chow and sensitivity to 8-OH-DPAT and quinpirole increased when rats that previously ate standard chow ate high fat chow. These data extend previous results showing changes in sensitivity to drugs acting on dopamine systems in animals eating high fat chow to a drug acting at 5-HT1A receptors and they provide support for the notion that eating certain foods impacts sensitivity to drugs acting on monoamine systems.

  19. Mass Spectrometry-based Assay for High Throughput and High Sensitivity Biomarker Verification

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Xuejiang; Tang, Keqi

    2017-06-14

    Searching for disease specific biomarkers has become a major undertaking in the biomedical research field as the effective diagnosis, prognosis and treatment of many complex human diseases are largely determined by the availability and the quality of the biomarkers. A successful biomarker as an indicator to a specific biological or pathological process is usually selected from a large group of candidates by a strict verification and validation process. To be clinically useful, the validated biomarkers must be detectable and quantifiable by the selected testing techniques in their related tissues or body fluids. Due to its easy accessibility, protein biomarkers would ideally be identified in blood plasma or serum. However, most disease related protein biomarkers in blood exist at very low concentrations (<1ng/mL) and are “masked” by many none significant species at orders of magnitude higher concentrations. The extreme requirements of measurement sensitivity, dynamic range and specificity make the method development extremely challenging. The current clinical protein biomarker measurement primarily relies on antibody based immunoassays, such as ELISA. Although the technique is sensitive and highly specific, the development of high quality protein antibody is both expensive and time consuming. The limited capability of assay multiplexing also makes the measurement an extremely low throughput one rendering it impractical when hundreds to thousands potential biomarkers need to be quantitatively measured across multiple samples. Mass spectrometry (MS)-based assays have recently shown to be a viable alternative for high throughput and quantitative candidate protein biomarker verification. Among them, the triple quadrupole MS based assay is the most promising one. When it is coupled with liquid chromatography (LC) separation and electrospray ionization (ESI) source, a triple quadrupole mass spectrometer operating in a special selected reaction monitoring (SRM) mode

  20. High-Sensitivity Measurement of Density by Magnetic Levitation.

    Science.gov (United States)

    Nemiroski, Alex; Kumar, A A; Soh, Siowling; Harburg, Daniel V; Yu, Hai-Dong; Whitesides, George M

    2016-03-01

    This paper presents methods that use Magnetic Levitation (MagLev) to measure very small differences in density of solid diamagnetic objects suspended in a paramagnetic medium. Previous work in this field has shown that, while it is a convenient method, standard MagLev (i.e., where the direction of magnetization and gravitational force are parallel) cannot resolve differences in density mm) because (i) objects close in density prevent each other from reaching an equilibrium height due to hard contact and excluded volume, and (ii) using weaker magnets or reducing the magnetic susceptibility of the medium destabilizes the magnetic trap. The present work investigates the use of weak magnetic gradients parallel to the faces of the magnets as a means of increasing the sensitivity of MagLev without destabilization. Configuring the MagLev device in a rotated state (i.e., where the direction of magnetization and gravitational force are perpendicular) relative to the standard configuration enables simple measurements along the axes with the highest sensitivity to changes in density. Manipulating the distance of separation between the magnets or the lengths of the magnets (along the axis of measurement) enables the sensitivity to be tuned. These modifications enable an improvement in the resolution up to 100-fold over the standard configuration, and measurements with resolution down to 10(-6) g/cm(3). Three examples of characterizing the small differences in density among samples of materials having ostensibly indistinguishable densities-Nylon spheres, PMMA spheres, and drug spheres-demonstrate the applicability of rotated Maglev to measuring the density of small (0.1-1 mm) objects with high sensitivity. This capability will be useful in materials science, separations, and quality control of manufactured objects.

  1. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili, E-mail: wangnsrl@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029 (China); Zhang, Kai [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Zhu, Peiping; Wu, Ziyu, E-mail: wuzy@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China and Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2015-02-15

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.

  2. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili; Zhang, Kai; Zhu, Peiping; Wu, Ziyu

    2015-01-01

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations

  3. High-sensitivity C-reactive protein predicts target organ damage in Chinese patients with metabolic syndrome

    DEFF Research Database (Denmark)

    Zhao, Zhigang; Nie, Hai; He, Hongbo

    2007-01-01

    with metabolic syndrome. A total of 1082 consecutive patients of Chinese origin were screened for the presence of metabolic syndrome according to the National Cholesterol Education Program's Adult Treatment Panel III. High-sensitivity C-reactive protein and target organ damage, including cardiac hypertrophy......Observational studies established high-sensitivity C-reactive protein as a risk factor for cardiovascular events in the general population. The goal of this study was to determine the relationship between target organ damage and high-sensitivity C-reactive protein in a cohort of Chinese patients......, carotid intima-media thickness, and renal impairment, were investigated. The median (25th and 75th percentiles) of high-sensitivity C-reactive protein in 619 patients with metabolic syndrome was 2.42 mg/L (0.75 and 3.66 mg/L) compared with 1.13 mg/L (0.51 and 2.46 mg/L) among 463 control subjects (P

  4. Highly sensitive wearable strain sensor based on silver nanowires and nanoparticles

    Science.gov (United States)

    Shengbo, Sang; Lihua, Liu; Aoqun, Jian; Qianqian, Duan; Jianlong, Ji; Qiang, Zhang; Wendong, Zhang

    2018-06-01

    Here, we propose a highly sensitive and stretchable strain sensor based on silver nanoparticles and nanowires (Ag NPs and NWs), advancing the rapid development of electronic skin. To improve the sensitivity of strain sensors based on silver nanowires (Ag NWs), Ag NPs and NWs were added to polydimethylsiloxane (PDMS) as an aid filler. Silver nanoparticles (Ag NPs) increase the conductive paths for electrons, leading to the low resistance of the resulting sensor (14.9 Ω). The strain sensor based on Ag NPs and NWs showed strong piezoresistivity with a tunable gauge factor (GF) at 3766, and a change in resistance as the strain linearly increased from 0% to 28.1%. The high GF demonstrates the irreplaceable role of Ag NPs in the sensor. Moreover, the applicability of our high-performance strain sensor has been demonstrated by its ability to sense movements caused by human talking, finger bending, wrist raising and walking.

  5. Design of a high-sensitivity classifier based on a genetic algorithm: application to computer-aided diagnosis

    International Nuclear Information System (INIS)

    Sahiner, Berkman; Chan, Heang-Ping; Petrick, Nicholas; Helvie, Mark A.; Goodsitt, Mitchell M.

    1998-01-01

    A genetic algorithm (GA) based feature selection method was developed for the design of high-sensitivity classifiers, which were tailored to yield high sensitivity with high specificity. The fitness function of the GA was based on the receiver operating characteristic (ROC) partial area index, which is defined as the average specificity above a given sensitivity threshold. The designed GA evolved towards the selection of feature combinations which yielded high specificity in the high-sensitivity region of the ROC curve, regardless of the performance at low sensitivity. This is a desirable quality of a classifier used for breast lesion characterization, since the focus in breast lesion characterization is to diagnose correctly as many benign lesions as possible without missing malignancies. The high-sensitivity classifier, formulated as the Fisher's linear discriminant using GA-selected feature variables, was employed to classify 255 biopsy-proven mammographic masses as malignant or benign. The mammograms were digitized at a pixel size of 0.1mmx0.1mm, and regions of interest (ROIs) containing the biopsied masses were extracted by an experienced radiologist. A recently developed image transformation technique, referred to as the rubber-band straightening transform, was applied to the ROIs. Texture features extracted from the spatial grey-level dependence and run-length statistics matrices of the transformed ROIs were used to distinguish malignant and benign masses. The classification accuracy of the high-sensitivity classifier was compared with that of linear discriminant analysis with stepwise feature selection (LDA sfs ). With proper GA training, the ROC partial area of the high-sensitivity classifier above a true-positive fraction of 0.95 was significantly larger than that of LDA sfs , although the latter provided a higher total area (A z ) under the ROC curve. By setting an appropriate decision threshold, the high-sensitivity classifier and LDA sfs correctly

  6. Highly sensitive detection of urinary cadmium to assess personal exposure

    Energy Technology Data Exchange (ETDEWEB)

    Argun, Avni A.; Banks, Ashley M.; Merlen, Gwendolynne; Tempelman, Linda A. [Giner, Inc., 89 Rumford Ave., Newton 02466, MA United States (United States); Becker, Michael F.; Schuelke, Thomas [Fraunhofer USA – CCL, 1449 Engineering Research Ct., East Lansing 48824, MI (United States); Dweik, Badawi M., E-mail: bdweik@ginerinc.com [Giner, Inc., 89 Rumford Ave., Newton 02466, MA United States (United States)

    2013-04-22

    Highlights: ► An electrochemical sensor capable of detecting cadmium at parts-per-billion levels in urine. ► A novel fabrication method for Boron-Doped Diamond (BDD) ultramicroelectrode (UME) arrays. ► Unique combination of BDD UME arrays and a differential pulse voltammetry algorithm. ► High sensitivity, high reproducibility, and very low noise levels. ► Opportunity for portable operation to assess on-site personal exposure. -- Abstract: A series of Boron-Doped Diamond (BDD) ultramicroelectrode arrays were fabricated and investigated for their performance as electrochemical sensors to detect trace level metals such as cadmium. The steady-state diffusion behavior of these sensors was validated using cyclic voltammetry followed by electrochemical detection of cadmium in water and in human urine to demonstrate high sensitivity (>200 μA ppb{sup −1} cm{sup −2}) and low background current (<4 nA). When an array of ultramicroelectrodes was positioned with optimal spacing, these BDD sensors showed a sigmoidal diffusion behavior. They also demonstrated high accuracy with linear dose dependence for quantification of cadmium in a certified reference river water sample from the U.S. National Institute of Standards and Technology (NIST) as well as in a human urine sample spiked with 0.25–1 ppb cadmium.

  7. The evaluation of B-type Natriuretic Peptide and Troponin I in acute myocardial infarction and unstable angina

    Directory of Open Access Journals (Sweden)

    Nafija Serdarevic

    2014-09-01

    Full Text Available Introduction: The diagnostic utility of B-type natriuretic peptide (BNP has prompted interest in its use as an aid in the detection of early heart failure and assessment of diseases. The first objective of this study was measurement of BNP and troponin I (TnI blood levels in patients with acute myocardial infarction (AMI and unstable angina. The second objective of this study was to find a correlation between TnI and BNP in blood.Methods: The concentrations of BNP and TnI in 150 blood levels were determined using CMIA (chemiluminescent microparticle immunoassay Architect and 2000 (Abbott diagnostics. The retrospective study included 100 patients who were hospitalized at the Department of Internal Medicine of the University Clinical Center Sarajevo and 50 healthy control. The reference blood range of BNP is 0-100 pg/mL and TnI is 0.00-0.4 ng/mL.Results: In the patients with AMI the mean value of BNP is 764.48 ± 639.52 pg/mL and TnI is 2.50 ± 2.28ng/mL. The patients with unstable angina have BNP 287.18 ± 593.20 pg/mL and TnI 0.10 ± 0.23 ng/mL. Our studies have shown that the correlation between BNP and TnI was statistically significant for p< 0.05 using Student t test with correlation coefficient r = 0.36. Conclusions: BNP and TnI levels can help to identify the patients with a high risk for cardiovascular diseases.

  8. Online high sensitivity measurement system for transuranic aerosols

    International Nuclear Information System (INIS)

    Kordas, J.F.; Phelps, P.L.

    1976-01-01

    A measurement system for transuranic aerosols has been designed that will be able to withstand the corrosive nature of stack effluents and yet have extremely high sensitivity. It will be capable of measuring 1 maximum permissible concentration (MPC) of plutonium or americium in 30 minutes with a fractional standard deviation of less than 0.33. Background resulting from 218 Po is eliminated by alpha energy discrimination and a decay scheme analysis. A microprocessor controls all data acquisition, data reduction, and instrument calibration

  9. High Excitation Transfer Efficiency from Energy Relay Dyes in Dye-Sensitized Solar Cells

    KAUST Repository

    Hardin, Brian E.

    2010-08-11

    The energy relay dye, 4-(Dicyanomethylene)-2-methyl-6-(4- dimethylaminostyryl)-4H-pyran (DCM), was used with a near-infrared sensitizing dye, TT1, to increase the overall power conversion efficiency of a dye-sensitized solar cell (DSC) from 3.5% to 4.5%. The unattached DCM dyes exhibit an average excitation transfer efficiency (EÌ?TE) of 96% inside TT1-covered, mesostructured TiO2 films. Further performance increases were limited by the solubility of DCM in an acetonitrile based electrolyte. This demonstration shows that energy relay dyes can be efficiently implemented in optimized dye-sensitized solar cells, but also highlights the need to design highly soluble energy relay dyes with high molar extinction coefficients. © 2010 American Chemical Society.

  10. The impact of hepatitis B carrier on cardiac troponin I in 100-km ultramarathon runners.

    Science.gov (United States)

    Li, Li-Hua; How, Chorng-Kuang; Kao, Wei-Fong; Chiu, Yu-Hui; Meng, Chen; Hsu, Cheng-Chin; Tsay, Yeou-Guang

    2017-06-01

    Prolonged endurance exercise is known to cause elevation of cardiac troponin I (cTnI). Previous studies have reported the correlation of several factors with exercise-induced cTnI release. However, the investigation of the predictors for elevated cTnI and postrace kinetics of cTnI after ultramarathon running is lacking, especially in an Oriental population. Twenty-six participants, including eight hepatitis B virus carrier (HBVc) runners, who finished a 100-km ultramarathon in Taiwan were enrolled. For each participant, blood samples were collected 1 week before the race, as well as immediately and 24 hours after the finish. The results showed that 19 runners (73.1%) had postrace elevated cTnI levels and eight (30.8%) had elevated cTnI values lasting more than 24 hours after the run. A multiple linear regression analysis demonstrated that the HBV status was a factor related to the high level of cTnI after 24 hours of running (β=0.03, p=0.08). The recovery of plasma cTnI levels was delayed in ultramarathon runners with latent HBV infection. Among HBVc runners, multiple linear regression analyses showed age (β=-0.01), previous running experience (β=-0.06), training distance (β=0.37), and 4 hours of running distance (β=-0.04) as significant predictors of higher postrace cTnI levels. For most athletes, cTnI values significantly increased immediately following the race in the absence of adverse clinical sequelae, and HBVc runners had higher and prolonged cTnI levels. While several factors are identified for such HBV effects, the specific causes need further elucidation. Copyright © 2017. Published by Elsevier Taiwan LLC.

  11. Highly Sensitive Liquid Core Temperature Sensor Based on Multimode Interference Effects

    Directory of Open Access Journals (Sweden)

    Miguel A. Fuentes-Fuentes

    2015-10-01

    Full Text Available A novel fiber optic temperature sensor based on a liquid-core multimode interference device is demonstrated. The advantage of such structure is that the thermo-optic coefficient (TOC of the liquid is at least one order of magnitude larger than that of silica and this, combined with the fact that the TOC of silica and the liquid have opposite signs, provides a liquid-core multimode fiber (MMF highly sensitive to temperature. Since the refractive index of the liquid can be easily modified, this allows us to control the modal properties of the liquid-core MMF at will and the sensor sensitivity can be easily tuned by selecting the refractive index of the liquid in the core of the device. The maximum sensitivity measured in our experiments is 20 nm/°C in the low-temperature regime up to 60 °C. To the best of our knowledge, to date, this is the largest sensitivity reported for fiber-based MMI temperature sensors.

  12. Nitrogen detected TROSY at high field yields high resolution and sensitivity for protein NMR

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Koh [National Institute for Advanced Industrial Science and Technology, Molecular Profiling Research Center for Drug Discovery (Japan); Arthanari, Haribabu [Harvard Medical School, Department of Biochemistry and Molecular Pharmacology (United States); Shimada, Ichio, E-mail: shimada@iw-nmr.f.u-tokyo.ac.jp [National Institute for Advanced Industrial Science and Technology, Molecular Profiling Research Center for Drug Discovery (Japan); Wagner, Gerhard, E-mail: gerhard-wagner@hms.harvard.edu [Harvard Medical School, Department of Biochemistry and Molecular Pharmacology (United States)

    2015-12-15

    Detection of {sup 15}N in multidimensional NMR experiments of proteins has sparsely been utilized because of the low gyromagnetic ratio (γ) of nitrogen and the presumed low sensitivity of such experiments. Here we show that selecting the TROSY components of proton-attached {sup 15}N nuclei (TROSY {sup 15}N{sub H}) yields high quality spectra in high field magnets (>600 MHz) by taking advantage of the slow {sup 15}N transverse relaxation and compensating for the inherently low {sup 15}N sensitivity. The {sup 15}N TROSY transverse relaxation rates increase modestly with molecular weight but the TROSY gain in peak heights depends strongly on the magnetic field strength. Theoretical simulations predict that the narrowest line width for the TROSY {sup 15}N{sub H} component can be obtained at 900 MHz, but sensitivity reaches its maximum around 1.2 GHz. Based on these considerations, a {sup 15}N-detected 2D {sup 1}H–{sup 15}N TROSY-HSQC ({sup 15}N-detected TROSY-HSQC) experiment was developed and high-quality 2D spectra were recorded at 800 MHz in 2 h for 1 mM maltose-binding protein at 278 K (τ{sub c} ∼ 40 ns). Unlike for {sup 1}H detected TROSY, deuteration is not mandatory to benefit {sup 15}N detected TROSY due to reduced dipolar broadening, which facilitates studies of proteins that cannot be deuterated, especially in cases where production requires eukaryotic expression systems. The option of recording {sup 15}N TROSY of proteins expressed in H{sub 2}O media also alleviates the problem of incomplete amide proton back exchange, which often hampers the detection of amide groups in the core of large molecular weight proteins that are expressed in D{sub 2}O culture media and cannot be refolded for amide back exchange. These results illustrate the potential of {sup 15}N{sub H}-detected TROSY experiments as a means to exploit the high resolution offered by high field magnets near and above 1 GHz.

  13. High spatial precision nano-imaging of polarization-sensitive plasmonic particles

    Science.gov (United States)

    Liu, Yunbo; Wang, Yipei; Lee, Somin Eunice

    2018-02-01

    Precise polarimetric imaging of polarization-sensitive nanoparticles is essential for resolving their accurate spatial positions beyond the diffraction limit. However, conventional technologies currently suffer from beam deviation errors which cannot be corrected beyond the diffraction limit. To overcome this issue, we experimentally demonstrate a spatially stable nano-imaging system for polarization-sensitive nanoparticles. In this study, we show that by integrating a voltage-tunable imaging variable polarizer with optical microscopy, we are able to suppress beam deviation errors. We expect that this nano-imaging system should allow for acquisition of accurate positional and polarization information from individual nanoparticles in applications where real-time, high precision spatial information is required.

  14. Flexible hemispheric microarrays of highly pressure-sensitive sensors based on breath figure method.

    Science.gov (United States)

    Wang, Zhihui; Zhang, Ling; Liu, Jin; Jiang, Hao; Li, Chunzhong

    2018-05-30

    Recently, flexible pressure sensors featuring high sensitivity, broad sensing range and real-time detection have aroused great attention owing to their crucial role in the development of artificial intelligent devices and healthcare systems. Herein, highly sensitive pressure sensors based on hemisphere-microarray flexible substrates are fabricated via inversely templating honeycomb structures deriving from a facile and static breath figure process. The interlocked and subtle microstructures greatly improve the sensing characteristics and compressibility of the as-prepared pressure sensor, endowing it a sensitivity as high as 196 kPa-1 and a wide pressure sensing range (0-100 kPa), as well as other superior performance, including a lower detection limit of 0.5 Pa, fast response time (10 000 cycles). Based on the outstanding sensing performance, the potential capability of our pressure sensor in capturing physiological information and recognizing speech signals has been demonstrated, indicating promising application in wearable and intelligent electronics.

  15. Highly sensitive optical chemosensor for the detection of Cu using a ...

    Indian Academy of Sciences (India)

    Administrator

    Highly sensitive colorimetric chemosensor molecule RHN for selective detection of Cu. 2+ in ... colour development against the colourless blank during the sensing event, a feature that would facilitate ... ever reported, much attention has been.

  16. Mesoporous structured MIPs@CDs fluorescence sensor for highly sensitive detection of TNT.

    Science.gov (United States)

    Xu, Shoufang; Lu, Hongzhi

    2016-11-15

    A facile strategy was developed to prepare mesoporous structured molecularly imprinted polymers capped carbon dots (M-MIPs@CDs) fluorescence sensor for highly sensitive and selective determination of TNT. The strategy using amino-CDs directly as "functional monomer" for imprinting simplify the imprinting process and provide well recognition sites accessibility. The as-prepared M-MIPs@CDs sensor, using periodic mesoporous silica as imprinting matrix, and amino-CDs directly as "functional monomer", exhibited excellent selectivity and sensitivity toward TNT with detection limit of 17nM. The recycling process was sustainable for 10 times without obvious efficiency decrease. The feasibility of the developed method in real samples was successfully evaluated through the analysis of TNT in soil and water samples with satisfactory recoveries of 88.6-95.7%. The method proposed in this work was proved to be a convenient and practical way to prepare high sensitive and selective fluorescence MIPs@CDs sensors. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. A wide range and highly sensitive optical fiber pH sensor using polyacrylamide hydrogel

    Science.gov (United States)

    Pathak, Akhilesh Kumar; Singh, Vinod Kumar

    2017-12-01

    In the present study we report the fabrication and characterization of no-core fiber sensor (NCFS) using smart hydrogel coating for pH measurement. The no-core fiber (NCF) is stubbed between two single-mode fibers with SMA connector before immobilizing of smart hydrogel. The wavelength interrogation technique is used to calculate the sensitivity of the proposed sensor. The result shows a high sensitivity of 1.94 nm/pH for a wide range of pH values varied from 3 to 10 with a good linear response. In addition to high sensitivity, the fabricated sensor provides a fast response time with a good stability, repeatability and reproducibility.

  18. Analysis of Cyberbullying Sensitivity Levels of High School Students and Their Perceived Social Support Levels

    Science.gov (United States)

    Akturk, Ahmet Oguz

    2015-01-01

    Purpose: The purpose of this paper is to determine the cyberbullying sensitivity levels of high school students and their perceived social supports levels, and analyze the variables that predict cyberbullying sensitivity. In addition, whether cyberbullying sensitivity levels and social support levels differed according to gender was also…

  19. High fat diet-fed obese rats are highly sensitive to doxorubicin-induced cardiotoxicity

    International Nuclear Information System (INIS)

    Mitra, Mayurranjan S.; Donthamsetty, Shashikiran; White, Brent; Mehendale, Harihara M.

    2008-01-01

    Often, chemotherapy by doxorubicin (Adriamycin) is limited due to life threatening cardiotoxicity in patients during and posttherapy. Recently, we have shown that moderate diet restriction remarkably protects against doxorubicin-induced cardiotoxicity. This cardioprotection is accompanied by decreased cardiac oxidative stress and triglycerides and increased cardiac fatty-acid oxidation, ATP synthesis, and upregulated JAK/STAT3 pathway. In the current study, we investigated whether a physiological intervention by feeding 40% high fat diet (HFD), which induces obesity in male Sprague-Dawley rats (250-275 g), sensitizes to doxorubicin-induced cardiotoxicity. A LD 10 dose (8 mg doxorubicin/kg, ip) administered on day 43 of the HFD feeding regimen led to higher cardiotoxicity, cardiac dysfunction, lipid peroxidation, and 80% mortality in the obese (OB) rats in the absence of any significant renal or hepatic toxicity. Doxorubicin toxicokinetics studies revealed no change in accumulation of doxorubicin and doxorubicinol (toxic metabolite) in the normal diet-fed (ND) and OB hearts. Mechanistic studies revealed that OB rats are sensitized due to: (1) higher oxyradical stress leading to upregulation of uncoupling proteins 2 and 3, (2) downregulation of cardiac peroxisome proliferators activated receptor-α, (3) decreased plasma adiponectin levels, (4) decreased cardiac fatty-acid oxidation (666.9 ± 14.0 nmol/min/g heart in ND versus 400.2 ± 11.8 nmol/min/g heart in OB), (5) decreased mitochondrial AMP-α2 protein kinase, and (6) 86% drop in cardiac ATP levels accompanied by decreased ATP/ADP ratio after doxorubicin administration. Decreased cardiac erythropoietin and increased SOCS3 further downregulated the cardioprotective JAK/STAT3 pathway. In conclusion, HFD-induced obese rats are highly sensitized to doxorubicin-induced cardiotoxicity by substantially downregulating cardiac mitochondrial ATP generation, increasing oxidative stress and downregulating the JAK/STAT3

  20. Environmental Sensitivity in Children: Development of the Highly Sensitive Child Scale and Identification of Sensitivity Groups

    Science.gov (United States)

    Pluess, Michael; Assary, Elham; Lionetti, Francesca; Lester, Kathryn J.; Krapohl, Eva; Aron, Elaine N.; Aron, Arthur

    2018-01-01

    A large number of studies document that children differ in the degree they are shaped by their developmental context with some being more sensitive to environmental influences than others. Multiple theories suggest that "Environmental Sensitivity" is a common trait predicting the response to negative as well as positive exposures.…

  1. Field test investigation of high sensitivity fiber optic seismic geophone

    Science.gov (United States)

    Wang, Meng; Min, Li; Zhang, Xiaolei; Zhang, Faxiang; Sun, Zhihui; Li, Shujuan; Wang, Chang; Zhao, Zhong; Hao, Guanghu

    2017-10-01

    Seismic reflection, whose measured signal is the artificial seismic waves ,is the most effective method and widely used in the geophysical prospecting. And this method can be used for exploration of oil, gas and coal. When a seismic wave travelling through the Earth encounters an interface between two materials with different acoustic impedances, some of the wave energy will reflect off the interface and some will refract through the interface. At its most basic, the seismic reflection technique consists of generating seismic waves and measuring the time taken for the waves to travel from the source, reflect off an interface and be detected by an array of geophones at the surface. Compared to traditional geophones such as electric, magnetic, mechanical and gas geophone, optical fiber geophones have many advantages. Optical fiber geophones can achieve sensing and signal transmission simultaneously. With the development of fiber grating sensor technology, fiber bragg grating (FBG) is being applied in seismic exploration and draws more and more attention to its advantage of anti-electromagnetic interference, high sensitivity and insensitivity to meteorological conditions. In this paper, we designed a high sensitivity geophone and tested its sensitivity, based on the theory of FBG sensing. The frequency response range is from 10 Hz to 100 Hz and the acceleration of the fiber optic seismic geophone is over 1000pm/g. sixteen-element fiber optic seismic geophone array system is presented and the field test is performed in Shengli oilfield of China. The field test shows that: (1) the fiber optic seismic geophone has a higher sensitivity than the traditional geophone between 1-100 Hz;(2) The low frequency reflection wave continuity of fiber Bragg grating geophone is better.

  2. High sensitivity tests of the standard model for electroweak interactions

    International Nuclear Information System (INIS)

    Koetke, D.D.

    1992-01-01

    The work done on this project was focussed mainly on LAMPF experiment E969 known as the MEGA experiment, a high sensitivity search for the lepton family number violating decay μ → eγ to a sensitivity which, measured in terms of the branching ratio, BR = [μ→eγ]/[μ→e ν μ ν e ] ∼10 -13 is over two orders of magnitude better than previously reported values. The work done on MEGA during this period was divided between that done at Valparaiso University and that done at LAMPF. In addition, some contributions were made to a proposal to the LAMPF PAC to perform a precision measurement of the Michel ρ parameter, described below

  3. High sensitive quench detection method using an integrated test wire

    International Nuclear Information System (INIS)

    Fevrier, A.; Tavergnier, J.P.; Nithart, H.; Kiblaire, M.; Duchateau, J.L.

    1981-01-01

    A high sensitive quench detection method which works even in the presence of an external perturbing magnetic field is reported. The quench signal is obtained from the difference in voltages at the superconducting winding terminals and at the terminals at a secondary winding strongly coupled to the primary. The secondary winding could consist of a ''zero-current strand'' of the superconducting cable not connected to one of the winding terminals or an integrated normal test wire inside the superconducting cable. Experimental results on quench detection obtained by this method are described. It is shown that the integrated test wire method leads to efficient and sensitive quench detection, especially in the presence of an external perturbing magnetic field

  4. A novel detection platform for parallel monitoring of DNA hybridization with high sensitivity and specificity

    DEFF Research Database (Denmark)

    Yi, Sun; Perch-Nielsen, Ivan R.; Wang, Zhenyu

    We developed a high-sensitive platform to monior multiple hybridization events in real time. By creating a microoptical array in a polymeric chip, the system combine the excellent discriminative power of supercritical angle fluorescence (SAF) microscopy with high-throughput capabilities of microa......We developed a high-sensitive platform to monior multiple hybridization events in real time. By creating a microoptical array in a polymeric chip, the system combine the excellent discriminative power of supercritical angle fluorescence (SAF) microscopy with high-throughput capabilities...

  5. Ultra-high sensitive hydrazine chemical sensor based on low-temperature grown ZnO nanoparticles

    International Nuclear Information System (INIS)

    Mehta, S.K.; Singh, Kulvinder; Umar, Ahmad; Chaudhary, G.R.; Singh, Sukhjinder

    2012-01-01

    Graphical abstract: Systematic representation of the fabricated amperometric hydrazine chemical sensor based on ZnO NPs/Au modified electrode. Highlights: ► Synthesis of well-crystalline ZnO NPs has been achieved in aqueous solution. ► ZnO NPs act as efficient electron mediators for hydrazine sensor. ► Extremely high sensitivity and low-detection limit have been obtained. - Abstract: Using well-crystalline ZnO nanoparticles (NPs), an ultra high sensitive hydrazine amperometric sensor has been fabricated and reported in this paper. The ZnO NPs have been synthesized by very simple aqueous solution process at 90 °C and characterized in detail in terms of their morphological, compositional, structural and optical properties. The detailed investigations reveal that the synthesized products are well-crystalline NPs, possessing wurtzite hexagonal phase and exhibit good optical properties. The fabricated amperometric hydrazine sensor exhibits ultra-high sensitivity of ∼97.133 μA cm −2 μM −1 and very low-detection limit of 147.54 nM. To the best of our knowledge, this is the first report in which an ultra-high sensitivity and low-detection limit have been obtained for the hydrazine chemical sensor based on ZnO nanostructures.

  6. Rats bred for high alcohol drinking are more sensitive to delayed and probabilistic outcomes.

    Science.gov (United States)

    Wilhelm, C J; Mitchell, S H

    2008-10-01

    Alcoholics and heavy drinkers score higher on measures of impulsivity than nonalcoholics and light drinkers. This may be because of factors that predate drug exposure (e.g. genetics). This study examined the role of genetics by comparing impulsivity measures in ethanol-naive rats selectively bred based on their high [high alcohol drinking (HAD)] or low [low alcohol drinking (LAD)] consumption of ethanol. Replicates 1 and 2 of the HAD and LAD rats, developed by the University of Indiana Alcohol Research Center, completed two different discounting tasks. Delay discounting examines sensitivity to rewards that are delayed in time and is commonly used to assess 'choice' impulsivity. Probability discounting examines sensitivity to the uncertain delivery of rewards and has been used to assess risk taking and risk assessment. High alcohol drinking rats discounted delayed and probabilistic rewards more steeply than LAD rats. Discount rates associated with probabilistic and delayed rewards were weakly correlated, while bias was strongly correlated with discount rate in both delay and probability discounting. The results suggest that selective breeding for high alcohol consumption selects for animals that are more sensitive to delayed and probabilistic outcomes. Sensitivity to delayed or probabilistic outcomes may be predictive of future drinking in genetically predisposed individuals.

  7. Myocardial Injury in Patients With Sepsis and Its Association With Long-Term Outcome.

    Science.gov (United States)

    Frencken, Jos F; Donker, Dirk W; Spitoni, Cristian; Koster-Brouwer, Marlies E; Soliman, Ivo W; Ong, David S Y; Horn, Janneke; van der Poll, Tom; van Klei, Wilton A; Bonten, Marc J M; Cremer, Olaf L

    2018-02-01

    Sepsis is frequently complicated by the release of cardiac troponin, but the clinical significance of this myocardial injury remains unclear. We studied the associations between troponin release during sepsis and 1-year outcomes. We enrolled consecutive patients with sepsis in 2 Dutch intensive care units between 2011 and 2013. Subjects with a clinically apparent cause of troponin release were excluded. High-sensitivity cardiac troponin I (hs-cTnI) concentration in plasma was measured daily during the first 4 intensive care unit days, and multivariable Cox regression analysis was used to model its association with 1-year mortality while adjusting for confounding. In addition, we studied cardiovascular morbidity occurring during the first year after hospital discharge. Among 1258 patients presenting with sepsis, 1124 (89%) were eligible for study inclusion. Hs-cTnI concentrations were elevated in 673 (60%) subjects on day 1, and 755 (67%) ever had elevated levels in the first 4 days. Cox regression analysis revealed that high hs-cTnI concentrations were associated with increased death rates during the first 14 days (adjusted hazard ratio, 1.72; 95% confidence interval, 1.14-2.59 and hazard ratio, 1.70; 95% confidence interval, 1.10-2.62 for hs-cTnI concentrations of 100-500 and >500 ng/L, respectively) but not thereafter. Furthermore, elevated hs-cTnI levels were associated with the development of cardiovascular disease among 200 hospital survivors who were analyzed for this end point (adjusted subdistribution hazard ratio, 1.25; 95% confidence interval, 1.04-1.50). Myocardial injury occurs in the majority of patients with sepsis and is independently associated with early-but not late-mortality, as well as postdischarge cardiovascular morbidity. © 2018 American Heart Association, Inc.

  8. Development of a high sensitivity pinhole type gamma camera using semiconductors for low dose rate fields

    Science.gov (United States)

    Ueno, Yuichiro; Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi; Fujishima, Yasutake; Yoshida, Akira; Umegaki, Kikuo

    2018-06-01

    We developed a pinhole type gamma camera, using a compact detector module of a pixelated CdTe semiconductor, which has suitable sensitivity and quantitative accuracy for low dose rate fields. In order to improve the sensitivity of the pinhole type semiconductor gamma camera, we adopted three methods: a signal processing method to set the discriminating level lower, a high sensitivity pinhole collimator and a smoothing image filter that improves the efficiency of the source identification. We tested basic performances of the developed gamma camera and carefully examined effects of the three methods. From the sensitivity test, we found that the effective sensitivity was about 21 times higher than that of the gamma camera for high dose rate fields which we had previously developed. We confirmed that the gamma camera had sufficient sensitivity and high quantitative accuracy; for example, a weak hot spot (0.9 μSv/h) around a tree root could be detected within 45 min in a low dose rate field test, and errors of measured dose rates with point sources were less than 7% in a dose rate accuracy test.

  9. High-Efficiency Dye-Sensitized Solar Cell with Three-Dimensional Photoanode

    KAUST Repository

    Tétreault, Nicolas

    2011-11-09

    Herein, we present a straightforward bottom-up synthesis of a high electron mobility and highly light scattering macroporous photoanode for dye-sensitized solar cells. The dense three-dimensional Al/ZnO, SnO2, or TiO 2 host integrates a conformal passivation thin film to reduce recombination and a large surface-area mesoporous anatase guest for high dye loading. This novel photoanode is designed to improve the charge extraction resulting in higher fill factor and photovoltage for DSCs. An increase in photovoltage of up to 110 mV over state-of-the-art DSC is demonstrated. © 2011 American Chemical Society.

  10. High-Efficiency Dye-Sensitized Solar Cell with Three-Dimensional Photoanode

    KAUST Repository

    Té treault, Nicolas; Arsenault, É ric; Heiniger, Leo-Philipp; Soheilnia, Navid; Brillet, Jé ré mie; Moehl, Thomas; Zakeeruddin, Shaik; Ozin, Geoffrey A.; Grä tzel, Michael

    2011-01-01

    Herein, we present a straightforward bottom-up synthesis of a high electron mobility and highly light scattering macroporous photoanode for dye-sensitized solar cells. The dense three-dimensional Al/ZnO, SnO2, or TiO 2 host integrates a conformal passivation thin film to reduce recombination and a large surface-area mesoporous anatase guest for high dye loading. This novel photoanode is designed to improve the charge extraction resulting in higher fill factor and photovoltage for DSCs. An increase in photovoltage of up to 110 mV over state-of-the-art DSC is demonstrated. © 2011 American Chemical Society.

  11. High sensitivity and high Q-factor nanoslotted parallel quadrabeam photonic crystal cavity for real-time and label-free sensing

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Daquan [Rowland Institute at Harvard University, Cambridge, Massachusetts 02142 (United States); State Key Laboratory of Information Photonics and Optical Communications, School of Information and Communication Engineering, Beijing University of Posts and Telecommunications, Beijing 100876 (China); School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts 02138 (United States); Kita, Shota; Wang, Cheng; Lončar, Marko [School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts 02138 (United States); Liang, Feng; Quan, Qimin [Rowland Institute at Harvard University, Cambridge, Massachusetts 02142 (United States); Tian, Huiping; Ji, Yuefeng [State Key Laboratory of Information Photonics and Optical Communications, School of Information and Communication Engineering, Beijing University of Posts and Telecommunications, Beijing 100876 (China)

    2014-08-11

    We experimentally demonstrate a label-free sensor based on nanoslotted parallel quadrabeam photonic crystal cavity (NPQC). The NPQC possesses both high sensitivity and high Q-factor. We achieved sensitivity (S) of 451 nm/refractive index unit and Q-factor >7000 in water at telecom wavelength range, featuring a sensor figure of merit >2000, an order of magnitude improvement over the previous photonic crystal sensors. In addition, we measured the streptavidin-biotin binding affinity and detected 10 ag/mL concentrated streptavidin in the phosphate buffered saline solution.

  12. BH5047 type depth sand moisture-meter of high sensitivity

    International Nuclear Information System (INIS)

    Ji Changsong; Xie Liangnian; Zhang Shulan; Zhang Shuheng

    2000-01-01

    A new depth neutron moisture meter BH5047 has been developed. BH5047 neutron moisture meter is characterised by it is high sensitivity and used for sand water content measurement at concrete mixer. Calibration function is obtained by the Method of Least Squares. Linear correlation efficiency is as good as 0.9977

  13. Incremental value of a combination of cardiac troponin T, N-terminal pro-brain natriuretic peptide and C-reactive protein for prediction of mortality in end-stage renal disease

    DEFF Research Database (Denmark)

    Hallén, Jonas; Madsen, Lene Helleskov; Ladefoged, Søren

    2011-01-01

    Abstract Objective. To determine the relative prognostic merits of C-reactive protein (CRP), cardiac troponin T (cTnT) and N-terminal pro-brain natriuretic peptide (NT-pro-BNP) for prediction of all-cause death in patients with end-stage renal disease (ESRD) receiving haemodialysis. Material...... and methods. This prospective, controlled cohort study included 109 patients. Biomarkers were sampled at inclusion and considered as categorical and continuous variables in Cox proportional hazard models. Results. Mean follow-up ± SD was 926 ± 385 days, during which 52 patients (48%) died. All three markers...

  14. Intra-Cavity Total Reflection For High Sensitivity Measurement Of Optical Properties

    Science.gov (United States)

    Pipino, Andrew Charles Rule

    1999-11-16

    An optical cavity resonator device is provided for conducting sensitive murement of optical absorption by matter in any state with diffraction-limited spatial resolution through utilization of total internal reflection within a high-Q (high quality, low loss) optical cavity. Intracavity total reflection generates an evanescent wave that decays exponentially in space at a point external to the cavity, thereby providing a localized region where absorbing materials can be sensitively probed through alteration of the Q-factor of the otherwise isolated cavity. When a laser pulse is injected into the cavity and passes through the evanescent state, an amplitude loss resulting from absorption is incurred that reduces the lifetime of the pulse in the cavity. By monitoring the decay of the injected pulse, the absorption coefficient of manner within the evanescent wave region is accurately obtained from the decay time measurement.

  15. Highly Sensitive and Very Stretchable Strain Sensor Based on a Rubbery Semiconductor.

    Science.gov (United States)

    Kim, Hae-Jin; Thukral, Anish; Yu, Cunjiang

    2018-02-07

    There is a growing interest in developing stretchable strain sensors to quantify the large mechanical deformation and strain associated with the activities for a wide range of species, such as humans, machines, and robots. Here, we report a novel stretchable strain sensor entirely in a rubber format by using a solution-processed rubbery semiconductor as the sensing material to achieve high sensitivity, large mechanical strain tolerance, and hysteresis-less and highly linear responses. Specifically, the rubbery semiconductor exploits π-π stacked poly(3-hexylthiophene-2,5-diyl) nanofibrils (P3HT-NFs) percolated in silicone elastomer of poly(dimethylsiloxane) to yield semiconducting nanocomposite with a large mechanical stretchability, although P3HT is a well-known nonstretchable semiconductor. The fabricated strain sensors exhibit reliable and reversible sensing capability, high gauge factor (gauge factor = 32), high linearity (R 2 > 0.996), and low hysteresis (degree of hysteresis wearable smart gloves. Systematic investigations in the materials design and synthesis, sensor fabrication and characterization, and mechanical analysis reveal the key fundamental and application aspects of the highly sensitive and very stretchable strain sensors entirely from rubbers.

  16. B-type natriuretic peptide: a novel early blood marker of acute myocardial infarction in patients with chest pain and no ST-segment elevation.

    Science.gov (United States)

    Bassan, Roberto; Potsch, Alfredo; Maisel, Alan; Tura, Bernardo; Villacorta, Humberto; Nogueira, Mônica Viegas; Campos, Augusta; Gamarski, Roberto; Masetto, Antonio Cláudio; Moutinho, Marco Aurélio

    2005-02-01

    This study was undertaken to determine the diagnostic value of admission B-type natriuretic peptide (BNP) for acute myocardial infarction (AMI) in patients with acute chest pain and no ST-segment elevation. A prospective study with 631 consecutive patients was conducted in the emergency department. Non-ST elevation AMI was present in 72 patients and their median admission BNP level was significantly higher than in unstable angina and non-acute coronary syndrome patients. Sensitivity of admission BNP for AMI (cut-off value of 100 pg/mL) was significantly higher than creatine kinase-MB (CKMB) and troponin-I on admission (70.8 vs. 45.8 vs. 50.7%, respectively, P<0.0001) and specificity was 68.9%. Simultaneous use of these markers significantly improved sensitivity to 87.3% and the negative predictive value to 97.3%. In multiple logistic regression analysis, admission BNP was a significant independent predictor of AMI, even when CKMB and troponin-I were present in the model. BNP is a useful adjunct to standard cardiac markers in patients presenting to the emergency department with chest pain and no ST-segment elevation, particularly if initial CKMB and/or troponin-I are non-diagnostic.

  17. Sensitivity of MENA Tropical Rainbelt to Dust Shortwave Absorption: A High Resolution AGCM Experiment

    KAUST Repository

    Bangalath, Hamza Kunhu; Stenchikov, Georgiy L.

    2016-01-01

    Shortwave absorption is one of the most important, but the most uncertain, components of direct radiative effect by mineral dust. It has a broad range of estimates from different observational and modeling studies and there is no consensus on the strength of absorption. To elucidate the sensitivity of the Middle East and North Africa (MENA) tropical summer rainbelt to a plausible range of uncertainty in dust shortwave absorption, AMIP-style global high resolution (25 km) simulations are conducted with and without dust, using the High-Resolution Atmospheric Model (HiRAM). Simulations with dust comprise three different cases by assuming dust as a very efficient, standard and inefficient absorber. Inter-comparison of these simulations shows that the response of the MENA tropical rainbelt is extremely sensitive to the strength of shortwave absorption. Further analyses reveal that the sensitivity of the rainbelt stems from the sensitivity of the multi-scale circulations that define the rainbelt. The maximum response and sensitivity are predicted over the northern edge of the rainbelt, geographically over Sahel. The sensitivity of the responses over the Sahel, especially that of precipitation, is comparable to the mean state. Locally, the response in precipitation reaches up to 50% of the mean, while dust is assumed to be a very efficient absorber. Taking into account that Sahel has a very high climate variability and is extremely vulnerable to changes in precipitation, the present study suggests the importance of reducing uncertainty in dust shortwave absorption for a better simulation and interpretation of the Sahel climate.

  18. Sensitivity of MENA Tropical Rainbelt to Dust Shortwave Absorption: A High Resolution AGCM Experiment

    KAUST Repository

    Bangalath, Hamza Kunhu

    2016-06-13

    Shortwave absorption is one of the most important, but the most uncertain, components of direct radiative effect by mineral dust. It has a broad range of estimates from different observational and modeling studies and there is no consensus on the strength of absorption. To elucidate the sensitivity of the Middle East and North Africa (MENA) tropical summer rainbelt to a plausible range of uncertainty in dust shortwave absorption, AMIP-style global high resolution (25 km) simulations are conducted with and without dust, using the High-Resolution Atmospheric Model (HiRAM). Simulations with dust comprise three different cases by assuming dust as a very efficient, standard and inefficient absorber. Inter-comparison of these simulations shows that the response of the MENA tropical rainbelt is extremely sensitive to the strength of shortwave absorption. Further analyses reveal that the sensitivity of the rainbelt stems from the sensitivity of the multi-scale circulations that define the rainbelt. The maximum response and sensitivity are predicted over the northern edge of the rainbelt, geographically over Sahel. The sensitivity of the responses over the Sahel, especially that of precipitation, is comparable to the mean state. Locally, the response in precipitation reaches up to 50% of the mean, while dust is assumed to be a very efficient absorber. Taking into account that Sahel has a very high climate variability and is extremely vulnerable to changes in precipitation, the present study suggests the importance of reducing uncertainty in dust shortwave absorption for a better simulation and interpretation of the Sahel climate.

  19. A Novel High-Sensitivity, Low-Power, Liquid Crystal Temperature Sensor

    Directory of Open Access Journals (Sweden)

    José Francisco Algorri

    2014-04-01

    Full Text Available A novel temperature sensor based on nematic liquid crystal permittivity as a sensing magnitude, is presented. This sensor consists of a specific micrometric structure that gives considerable advantages from other previous related liquid crystal (LC sensors. The analytical study reveals that permittivity change with temperature is introduced in a hyperbolic cosine function, increasing the sensitivity term considerably. The experimental data has been obtained for ranges from −6 °C to 100 °C. Despite this, following the LC datasheet, theoretical ranges from −40 °C to 109 °C could be achieved. These results have revealed maximum sensitivities of 33 mVrms/°C for certain temperature ranges; three times more than of most silicon temperature sensors. As it was predicted by the analytical study, the micrometric size of the proposed structure produces a high output voltage. Moreover the voltage’s sensitivity to temperature response can be controlled by the applied voltage. This response allows temperature measurements to be carried out without any amplification or conditioning circuitry, with very low power consumption.

  20. Diabetes Mellitus, Microalbuminuria, and Subclinical Cardiac Disease: Identification and Monitoring of Individuals at Risk of Heart Failure.

    Science.gov (United States)

    Swoboda, Peter P; McDiarmid, Adam K; Erhayiem, Bara; Ripley, David P; Dobson, Laura E; Garg, Pankaj; Musa, Tarique A; Witte, Klaus K; Kearney, Mark T; Barth, Julian H; Ajjan, Ramzi; Greenwood, John P; Plein, Sven

    2017-07-17

    Patients with type 2 diabetes mellitus and elevated urinary albumin:creatinine ratio (ACR) have increased risk of heart failure. We hypothesized this was because of cardiac tissue changes rather than silent coronary artery disease. In a case-controlled observational study 130 subjects including 50 ACR+ve diabetes mellitus patients with persistent microalbuminuria (ACR >2.5 mg/mol in males and >3.5 mg/mol in females, ≥2 measurements, no previous renin-angiotensin-aldosterone therapy, 50 ACR-ve diabetes mellitus patients and 30 controls underwent cardiovascular magnetic resonance for investigation of myocardial fibrosis, ischemia and infarction, and echocardiography. Thirty ACR+ve patients underwent further testing after 1-year treatment with renin-angiotensin-aldosterone blockade. Cardiac extracellular volume fraction, a measure of diffuse fibrosis, was higher in diabetes mellitus patients than controls (26.1±3.4% and 23.3±3.0% P =0.0002) and in ACR+ve than ACR-ve diabetes mellitus patients (27.2±4.1% versus 25.1±2.9%, P =0.004). ACR+ve patients also had lower E' measured by echocardiography (8.2±1.9 cm/s versus 8.9±1.9 cm/s, P =0.04) and elevated high-sensitivity cardiac troponin T 18% versus 4% ≥14 ng/L ( P =0.05). Rate of silent myocardial ischemia or infarction were not influenced by ACR status. Renin-angiotensin-aldosterone blockade was associated with increased left ventricular ejection fraction (59.3±7.8 to 61.5±8.7%, P =0.03) and decreased extracellular volume fraction (26.5±3.6 to 25.2±3.1, P =0.01) but no changes in diastolic function or high-sensitivity cardiac troponin T levels. Asymptomatic diabetes mellitus patients with persistent microalbuminuria have markers of diffuse cardiac fibrosis including elevated extracellular volume fraction, high-sensitivity cardiac troponin T, and diastolic dysfunction, which may in part be reversible by renin-angiotensin-aldosterone blockade. Increased risk in these patients may be mediated by

  1. Development of an ozone high sensitive sensor working at ambient temperature

    International Nuclear Information System (INIS)

    Berger, F; Ghaddab, B; Sanchez, J B; Mavon, C

    2011-01-01

    Hybrid SnO 2 /SWNTs thin layer were deposited by using sol-gel process. Such sensitive layers showed very high performances for O 3 flow detection at ambient temperature. Limit sensitivity, lower than 21,5 ppb of O 3 in air has been reached by using these hybrid layers. Compared to usefull metal oxide sensors, the main advantage of the use of such hybrid layers, is that these devices enable the detection of O 3 traces at room temperature. The influence of sensor's working temperature is discussed and finally a reactional mechanism for the detection of O 3 is proposed.

  2. High sensitivity tests of the standard model for electroweak interactions

    International Nuclear Information System (INIS)

    Koetke, D.D.; Manweiler, R.W.; Shirvel Stanislaus, T.D.

    1993-01-01

    The work done on this project was focused on two LAMPF experiments. The MEGA experiment, a high-sensitivity search for the lepton-family-number-violating decay μ → e γ to a sensitivity which, measured in terms of the branching ratio, BR = [μ → e γ]/[μ → ev μ v e ] ∼ 10 -13 , is over two orders of magnitude better than previously reported values. The second is a precision measurement of the Michel ρ parameter from the positron energy spectrum of μ → ev μ v e to test the V-A theory of weak interactions. The uncertainty in the measurement of the Michel ρ parameter is expected to be a factor of three lower than the present reported value

  3. Highly sensitive chemiluminescent point mutation detection by circular strand-displacement amplification reaction.

    Science.gov (United States)

    Shi, Chao; Ge, Yujie; Gu, Hongxi; Ma, Cuiping

    2011-08-15

    Single nucleotide polymorphism (SNP) genotyping is attracting extensive attentions owing to its direct connections with human diseases including cancers. Here, we have developed a highly sensitive chemiluminescence biosensor based on circular strand-displacement amplification and the separation by magnetic beads reducing the background signal for point mutation detection at room temperature. This method took advantage of both the T4 DNA ligase recognizing single-base mismatch with high selectivity and the strand-displacement reaction of polymerase to perform signal amplification. The detection limit of this method was 1.3 × 10(-16)M, which showed better sensitivity than that of most of those reported detection methods of SNP. Additionally, the magnetic beads as carrier of immobility was not only to reduce the background signal, but also may have potential apply in high through-put screening of SNP detection in human genome. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. A highly sensitive pressure sensor using a Au-patterned polydimethylsiloxane membrane for biosensing applications

    International Nuclear Information System (INIS)

    Liu, Xinchuan; Zhu, Yihao; Nomani, Md W; Koley, Goutam; Wen, Xuejun; Hsia, Tain-Yen

    2013-01-01

    We report on the fabrication and characterization of a highly sensitive pressure sensor using a Au film patterned on a polydimethylsiloxane (PDMS) membrane. The strain-induced change in the film resistance was utilized to perform the quantitative measurement of absolute pressure. The highest sensitivity obtained for a 200 µm thick PDMS film sensor was 0.23/KPa with a range of 50 mm Hg, which is the best result reported so far, over that range, for any pressure sensor on a flexible membrane. The noise-limited pressure resolution was found to be 0.9 Pa (0.007 mm Hg), and a response time of ∼200 ms, are the best reported results for these sensors. The ultrahigh sensitivity is attributed to the strain-induced formation of microcracks, the effect of which on the resistance change was found to be highly reversible within a certain pressure range. A physical model correlating the sensitivity with the sensor parameters and crack geometry has been proposed. (paper)

  5. High-sensitivity visualization of localized electric fields using low-energy electron beam deflection

    Science.gov (United States)

    Jeong, Samuel; Ito, Yoshikazu; Edwards, Gary; Fujita, Jun-ichi

    2018-06-01

    The visualization of localized electronic charges on nanocatalysts is expected to yield fundamental information about catalytic reaction mechanisms. We have developed a high-sensitivity detection technique for the visualization of localized charges on a catalyst and their corresponding electric field distribution, using a low-energy beam of 1 to 5 keV electrons and a high-sensitivity scanning transmission electron microscope (STEM) detector. The highest sensitivity for visualizing a localized electric field was ∼0.08 V/µm at a distance of ∼17 µm from a localized charge at 1 keV of the primary electron energy, and a weak local electric field produced by 200 electrons accumulated on the carbon nanotube (CNT) apex can be visualized. We also observed that Au nanoparticles distributed on a CNT forest tended to accumulate a certain amount of charges, about 150 electrons, at a ‑2 V bias.

  6. Transportable high sensitivity small sample radiometric calorimeter

    International Nuclear Information System (INIS)

    Wetzel, J.R.; Biddle, R.S.; Cordova, B.S.; Sampson, T.E.; Dye, H.R.; McDow, J.G.

    1998-01-01

    A new small-sample, high-sensitivity transportable radiometric calorimeter, which can be operated in different modes, contains an electrical calibration method, and can be used to develop secondary standards, will be described in this presentation. The data taken from preliminary tests will be presented to indicate the precision and accuracy of the instrument. The calorimeter and temperature-controlled bath, at present, require only a 30-in. by 20-in. tabletop area. The calorimeter is operated from a laptop computer system using unique measurement module capable of monitoring all necessary calorimeter signals. The calorimeter can be operated in the normal calorimeter equilibration mode, as a comparison instrument, using twin chambers and an external electrical calibration method. The sample chamber is 0.75 in (1.9 cm) in diameter by 2.5 in. (6.35 cm) long. This size will accommodate most 238 Pu heat standards manufactured in the past. The power range runs from 0.001 W to <20 W. The high end is only limited by sample size

  7. Quartz crystal microbalance-based system for high-sensitivity differential sputter yield measurements

    International Nuclear Information System (INIS)

    Rubin, B.; Topper, J. L.; Farnell, C. C.; Yalin, A. P.

    2009-01-01

    We present a quartz crystal microbalance-based system for high sensitivity differential sputter yield measurements of different target materials due to ion bombardment. The differential sputter yields can be integrated to find total yields. Possible ion beam conditions include ion energies in the range of 30-350 eV and incidence angles of 0 deg. - 70 deg. from normal. A four-grid ion optics system is used to achieve a collimated ion beam at low energy (<100 eV) and a two-grid ion optics is used for higher energies (up to 750 eV). A complementary weight loss approach is also used to measure total sputter yields. Validation experiments are presented that confirm high sensitivity and accuracy of sputter yield measurements.

  8. High sensitivity on-line monitor for radioactive effluent

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Toshimi [Tohoku Electric Power Co. Ltd., Sendai (Japan); Ishizuka, Akira; Abe, Eisuke; Inoue, Yasuhiko; Fujii, Masaaki; Kitaguchi, Hiroshi; Doi, Akira

    1983-04-01

    A new approach for a highly sensitive effluent monitor is presented. The free flow type monitor, which consists of a straightener, nozzle, monitoring section and ..gamma..-ray detector, is demonstrated to be effective in providing long term stability. The 160 start-and-stop cycles of effluent discharge were repeated in a 120-h testing period. Results showed a background increase was not observed for the free flow type monitor. The background count rate was calibrated to the lowest detection limit to be 2.2 x 10/sup -2/ Bq/ml for a 300 s measurement time.

  9. Superior Predictive Value for NTproBNP Compared with High Sensitivity cTnT in Dialysis Patients: A Pilot Prospective Observational Study

    Directory of Open Access Journals (Sweden)

    Luminita Voroneanu

    2014-12-01

    Full Text Available Background/Aims: The clinical utility of the new biomarker, high sensitivity cardiac T troponin (hs-cTnT is still unclear in dialysis patients. Furthermore, the prognostic value of combining N-terminal pro-B-type natriuretic peptide (NT-pro-BNP and hs-cTnT has not been explored so far. The objective of this pilot study was to determine the utility of hs-cTnT alone versus hs-cTnT in combination with NT-proBNP for predicting death in a stable hemodialysis cohort. Methods: A prospective observational pilot study including 98 chronic asymptomatic hemodialysis patients with a follow up period of 24 months was designed. The cut-off values for NT-proBNP and hs-cTnT were calculated using receiver operating characteristic (ROC analysis, using mortality as an end-point. Based on the cut-off values, the cohort was divided into four groups. Group 1 - NT-proBNP 69.48 ng/l; group 3 - NT-proBNP > 14275 pg/ml and hs-cTnT 14275 pg/ml and hs-cTnT > 69.48 ng/l. Survival for each group was determined using the Kaplan-Meier method and Cox regression analysis. Results: During the follow-up period 16 patients died. According to the ROC curves analysis, the cut-off point for hs-cTnT and for NT-proBNP were 69.43 ng/l (AUC = 0.618; p = 0.04 and 14275 pg/ml (AUC = 0.722; p = 0.003, respectively. In univariate Cox analysis, both hs-cTnT (HR = 3.34; p = 0.016 and NT-proBNP (HR = 5.94; p = 0.01 were predictors of death. In the multivariable Cox proportional hazards model, only NT-pro-BNP levels above the cut-off value remained an independent predictor of all-cause mortality. The combined elevation of both biomarkers did not improve significantly the prognostic value compared with NT-proBNP alone (HR = 6.15 versus HR =4 .78; p = 0.338. Conclusion: NT-pro-BNP is a strong predictor of overall mortality in asymptomatic hemodialysis patients. The addition of hs-cTnT did not improve the prognostic accuracy compared with NT proBNP alone.

  10. Addressing Curse of Dimensionality in Sensitivity Analysis: How Can We Handle High-Dimensional Problems?

    Science.gov (United States)

    Safaei, S.; Haghnegahdar, A.; Razavi, S.

    2016-12-01

    Complex environmental models are now the primary tool to inform decision makers for the current or future management of environmental resources under the climate and environmental changes. These complex models often contain a large number of parameters that need to be determined by a computationally intensive calibration procedure. Sensitivity analysis (SA) is a very useful tool that not only allows for understanding the model behavior, but also helps in reducing the number of calibration parameters by identifying unimportant ones. The issue is that most global sensitivity techniques are highly computationally demanding themselves for generating robust and stable sensitivity metrics over the entire model response surface. Recently, a novel global sensitivity analysis method, Variogram Analysis of Response Surfaces (VARS), is introduced that can efficiently provide a comprehensive assessment of global sensitivity using the Variogram concept. In this work, we aim to evaluate the effectiveness of this highly efficient GSA method in saving computational burden, when applied to systems with extra-large number of input factors ( 100). We use a test function and a hydrological modelling case study to demonstrate the capability of VARS method in reducing problem dimensionality by identifying important vs unimportant input factors.

  11. A highly sensitive multiplasmonic sensor using hyperbolic chiral sculptured thin films

    Science.gov (United States)

    Abbas, Farhat; Faryad, Muhammad

    2017-11-01

    Surface plasmon-polariton (SPP) waves guided by an interface of a metal and a hyperbolic chiral sculptured thin film (STF) were theoretically investigated for optical sensing of an analyte. The chiral STF was infiltrated with the analyte to be sensed, and the resulting change in the incidence angle of excitation of the SPP waves in the prism-coupled configuration was computed. The results indicated the potential of this configuration for a plasmonic sensor with sensitivity up to 6000 degrees per refractive index units of the infiltrating fluid in the angular investigation scheme, with multiple SPP waves of the same frequency but different phase speeds, spatial profiles, and sensitivities. The enhancement in the sensitivity is attributed to the high field strength of the SPP waves near the interface. A multiplasmonic sensor is advantageous because of its potential for higher confidence in the measurement of the same analyte.

  12. A simple, tunable, and highly sensitive radio-frequency sensor.

    Science.gov (United States)

    Cui, Yan; Sun, Jiwei; He, Yuxi; Wang, Zheng; Wang, Pingshan

    2013-08-05

    We report a radio frequency (RF) sensor that exploits tunable attenuators and phase shifters to achieve high-sensitivity and broad band frequency tunability. Three frequency bands are combined to enable sensor operations from ∼20 MHz to ∼38 GHz. The effective quality factor ( Q eff ) of the sensor is as high as ∼3.8 × 10 6 with 200  μ l of water samples. We also demonstrate the measurement of 2-proponal-water-solution permittivity at 0.01 mole concentration level from ∼1 GHz to ∼10 GHz. Methanol-water solution and de-ionized water are used to calibrate the RF sensor for the quantitative measurements.

  13. Highly sensitive determination of atropine using cobalt oxide nanostructures: Influence of functional groups on the signal sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Soomro, Razium Ali, E-mail: raziumsoomro@gmail.com [Interface Analysis Centre, School of Physics, University of Bristol, Bristol, BS8 1TL (United Kingdom); National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080 (Pakistan); Nafady, Ayman [Department of Chemistry, College of Science, King Saud University, Riyadh (Saudi Arabia); Department of Chemistry, Faculty of Science, Sohag University, Sohag (Egypt); Hallam, Keith Richard [Interface Analysis Centre, School of Physics, University of Bristol, Bristol, BS8 1TL (United Kingdom); Jawaid, Sana [National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080 (Pakistan); Al Enizi, Abdullah [Department of Chemistry, College of Science, King Saud University, Riyadh (Saudi Arabia); Sherazi, Syed Tufail Hussain; Sirajuddin [National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080 (Pakistan); Ibupoto, Zafar Hussain [Dr M.A. Kazi Institute of Chemistry, University of Sindh, Jamshoro, 76080 (Pakistan); Willander, Magnus [Department of Science and Technology, Campus Norrkoping, Linkoping University, SE-60174, Norrkoping (Sweden)

    2016-12-15

    This study describes sensitive determination of atropine using glassy carbon electrodes (GCE) modified with Co{sub 3}O{sub 4} nanostructures. The as-synthesised nanostructures were grown using cysteine (CYS), glutathione (GSH) and histidine (HYS) as effective templates under hydrothermal action. The obtained morphologies revealed interesting structural features, including both cavity-based and flower-shaped structures. The as-synthesised morphologies were noted to actively participate in electro-catalysis of atropine (AT) drug where GSH-assisted structures exhibited the best signal response in terms of current density and over-potential value. The study also discusses the influence of functional groups on the signal sensitivity of atropine electro-oxidation. The functionalisation was carried with the amino acids originally used as effective templates for the growth of Co{sub 3}O{sub 4} nanostructures. The highest increment was obtained when GSH was used as the surface functionalising agent. The GSH-functionalised Co{sub 3}O{sub 4}-modified electrode was utilised for the electro-chemical sensing of AT in a concentration range of 0.01–0.46 μM. The developed sensor exhibited excellent working linearity (R{sup 2} = 0.999) and signal sensitivity up to 0.001 μM of AT. The noted high sensitivity of the sensor is associated with the synergy of superb surface architectures and favourable interaction facilitating the electron transfer kinetics for the electro-catalytic oxidation of AT. Significantly, the developed sensor demonstrated excellent working capability when used for AT detection in human urine samples with strong anti-interference potential against common co-existing species, such as glucose, fructose, cysteine, uric acid, dopamine and ascorbic acid. - Highlights: • Template-assisted growth of Co{sub 3}O{sub 4} nanostructures. • Shape-dependent electro-catalysis of atropine. • Effect of functionalisation of signal sensitivity.

  14. High-resolution nuclear magnetic resonance studies of proteins.

    Science.gov (United States)

    Jonas, Jiri

    2002-03-25

    The combination of advanced high-resolution nuclear magnetic resonance (NMR) techniques with high-pressure capability represents a powerful experimental tool in studies of protein folding. This review is organized as follows: after a general introduction of high-pressure, high-resolution NMR spectroscopy of proteins, the experimental part deals with instrumentation. The main section of the review is devoted to NMR studies of reversible pressure unfolding of proteins with special emphasis on pressure-assisted cold denaturation and the detection of folding intermediates. Recent studies investigating local perturbations in proteins and the experiments following the effects of point mutations on pressure stability of proteins are also discussed. Ribonuclease A, lysozyme, ubiquitin, apomyoglobin, alpha-lactalbumin and troponin C were the model proteins investigated.

  15. The nature and nurture of high IQ: an extended sensitive period for intellectual development.

    Science.gov (United States)

    Brant, Angela M; Munakata, Yuko; Boomsma, Dorret I; Defries, John C; Haworth, Claire M A; Keller, Matthew C; Martin, Nicholas G; McGue, Matthew; Petrill, Stephen A; Plomin, Robert; Wadsworth, Sally J; Wright, Margaret J; Hewitt, John K

    2013-08-01

    IQ predicts many measures of life success, as well as trajectories of brain development. Prolonged cortical thickening observed in individuals with high IQ might reflect an extended period of synaptogenesis and high environmental sensitivity or plasticity. We tested this hypothesis by examining the timing of changes in the magnitude of genetic and environmental influences on IQ as a function of IQ score. We found that individuals with high IQ show high environmental influence on IQ into adolescence (resembling younger children), whereas individuals with low IQ show high heritability of IQ in adolescence (resembling adults), a pattern consistent with an extended sensitive period for intellectual development in more-intelligent individuals. The pattern held across a cross-sectional sample of almost 11,000 twin pairs and a longitudinal sample of twins, biological siblings, and adoptive siblings.

  16. Highly sensitive uric acid biosensor based on individual zinc oxide micro/nanowires

    International Nuclear Information System (INIS)

    Zhao, Yanguang; Yan, Xiaoqin; Kang, Zhuo; Lin, Pei; Fang, Xiaofei; Lei, Yang; Ma, Siwei; Zhang, Yue

    2013-01-01

    We describe the use of individual zinc oxide (ZnO) micro/nanowires in an electrochemical biosensor for uric acid. The wires were synthesized by chemical vapor deposition and possess uniform morphology and high crystallinity as revealed by scanning electron microscopy, X-ray diffraction, and photoluminescence studies. The enzyme uricase was then immobilized on the surface of the ZnO micro/nanowires by physical adsorption, and this was proven by Raman spectroscopy and fluorescence microscopy. The resulting uric acid biosensor undergoes fast electron transfer between the active site of the enzyme and the surface of the electrode. It displays high sensitivity (89.74 μA cm −2 mM −1 ) and a wide linear analytical range (between 0.1 mM and 0.59 mM concentrations of uric acid). This study also demonstrates the potential of the use of individual ZnO micro/nanowires for the construction of highly sensitive nano-sized biosensors. (author)

  17. A Monolithic CMOS Magnetic Hall Sensor with High Sensitivity and Linearity Characteristics.

    Science.gov (United States)

    Huang, Haiyun; Wang, Dejun; Xu, Yue

    2015-10-27

    This paper presents a fully integrated linear Hall sensor by means of 0.8 μm high voltage complementary metal-oxide semiconductor (CMOS) technology. This monolithic Hall sensor chip features a highly sensitive horizontal switched Hall plate and an efficient signal conditioner using dynamic offset cancellation technique. An improved cross-like Hall plate achieves high magnetic sensitivity and low offset. A new spinning current modulator stabilizes the quiescent output voltage and improves the reliability of the signal conditioner. The tested results show that at the 5 V supply voltage, the maximum Hall output voltage of the monolithic Hall sensor microsystem, is up to ±2.1 V and the linearity of Hall output voltage is higher than 99% in the magnetic flux density range from ±5 mT to ±175 mT. The output equivalent residual offset is 0.48 mT and the static power consumption is 20 mW.

  18. A Monolithic CMOS Magnetic Hall Sensor with High Sensitivity and Linearity Characteristics

    Directory of Open Access Journals (Sweden)

    Haiyun Huang

    2015-10-01

    Full Text Available This paper presents a fully integrated linear Hall sensor by means of 0.8 μm high voltage complementary metal-oxide semiconductor (CMOS technology. This monolithic Hall sensor chip features a highly sensitive horizontal switched Hall plate and an efficient signal conditioner using dynamic offset cancellation technique. An improved cross-like Hall plate achieves high magnetic sensitivity and low offset. A new spinning current modulator stabilizes the quiescent output voltage and improves the reliability of the signal conditioner. The tested results show that at the 5 V supply voltage, the maximum Hall output voltage of the monolithic Hall sensor microsystem, is up to ±2.1 V and the linearity of Hall output voltage is higher than 99% in the magnetic flux density range from ±5 mT to ±175 mT. The output equivalent residual offset is 0.48 mT and the static power consumption is 20 mW.

  19. Development of miniature γ dose rate monitor with high sensitivity

    International Nuclear Information System (INIS)

    Shi Huilu; Tuo Xianguo; Xi Dashun; Tang Rong; Mu Keliang; Yang Jianbo

    2009-01-01

    This paper introduces a miniature γ dose rate monitor with high sensitivity which design based on single chip microcomputer, it can continue monitoring γ dose rate and then choose wire or wireless communications to sent the monitoring data to host according to the actual conditions. It has two kinds of power supply system, AC power supply system and battery which can be chose by concrete circumstances. The design idea and implementation technology of hardware and software and the system structure of the monitor are detailed illustrated in this paper. The experimental results show that measurable range is 0.1 mR/h-200 mR/h, the sensitivity of γ is 90 cps/mR/h, dead time below 200 us, error of stability below ±10%. (authors)

  20. RAMA casein zymography: Time-saving and highly sensitive casein zymography for MMP7 and trypsin.

    Science.gov (United States)

    Yasumitsu, Hidetaro; Ozeki, Yasuhiro; Kanaly, Robert A

    2016-11-01

    To detect metalloproteinase-7 (MMP7), zymography is conducted using a casein substrate and conventional CBB stain. It has disadvantages because it is time consuming and has low sensitivity. Previously, a sensitive method to detect MMP7 up to 30 pg was reported, however it required special substrates and complicated handlings. RAMA casein zymography described herein is rapid, sensitive, and reproducible. By applying high-sensitivity staining with low substrate conditions, the staining process is completed within 1 h and sensitivity was increased 100-fold. The method can detect 10 pg MMP7 by using commercially available casein without complicated handlings. Moreover, it increases detection sensitivity for trypsin. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Palladium Gate All Around - Hetero Dielectric -Tunnel FET based highly sensitive Hydrogen Gas Sensor

    Science.gov (United States)

    Madan, Jaya; Chaujar, Rishu

    2016-12-01

    The paper presents a novel highly sensitive Hetero-Dielectric-Gate All Around Tunneling FET (HD-GAA-TFET) based Hydrogen Gas Sensor, incorporating the advantages of band to band tunneling (BTBT) mechanism. Here, the Palladium supported silicon dioxide is used as a sensing media and sensing relies on the interaction of hydrogen with Palladium-SiO2-Si. The high surface to volume ratio in the case of cylindrical GAA structure enhances the fortuities for surface reactions between H2 gas and Pd, and thus improves the sensitivity and stability of the sensor. Behaviour of the sensor in presence of hydrogen and at elevated temperatures is discussed. The conduction path of the sensor which is dependent on sensors radius has also been varied for the optimized sensitivity and static performance analysis of the sensor where the proposed design exhibits a superior performance in terms of threshold voltage, subthreshold swing, and band to band tunneling rate. Stability of the sensor with respect to temperature affectability has also been studied, and it is found that the device is reasonably stable and highly sensitive over the bearable temperature range. The successful utilization of HD-GAA-TFET in gas sensors may open a new door for the development of novel nanostructure gas sensing devices.

  2. Determination of Chlorinated Hydrocarbons in Water Using Highly Sensitive Mid-Infrared Sensor Technology

    Science.gov (United States)

    Lu, Rui; Mizaikoff, Boris; Li, Wen-Wei; Qian, Chen; Katzir, Abraham; Raichlin, Yosef; Sheng, Guo-Ping; Yu, Han-Qing

    2013-08-01

    Chlorinated aliphatic hydrocarbons and chlorinated aromatic hydrocarbons (CHCs) are toxic and carcinogenic contaminants commonly found in environmental samples, and efficient online detection of these contaminants is still challenging at the present stage. Here, we report an advanced Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) sensor for in-situ and simultaneous detection of multiple CHCs, including monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, trichloroethylene, perchloroethylene, and chloroform. The polycrystalline silver halide sensor fiber had a unique integrated planar-cylindric geometry, and was coated with an ethylene/propylene copolymer membrane to act as a solid phase extractor, which greatly amplified the analytical signal and contributed to a higher detection sensitivity compared to the previously reported sensors. This system exhibited a high detection sensitivity towards the CHCs mixture at a wide concentration range of 5~700 ppb. The FTIR-ATR sensor described in this study has a high potential to be utilized as a trace-sensitive on-line device for water contamination monitoring.

  3. The Manchester Acute Coronary Syndromes (MACS) decision rule: validation with a new automated assay for heart-type fatty acid binding protein.

    Science.gov (United States)

    Body, Richard; Burrows, Gillian; Carley, Simon; Lewis, Philip S

    2015-10-01

    The Manchester Acute Coronary Syndromes (MACS) decision rule may enable acute coronary syndromes to be immediately 'ruled in' or 'ruled out' in the emergency department. The rule incorporates heart-type fatty acid binding protein (h-FABP) and high sensitivity troponin T levels. The rule was previously validated using a semiautomated h-FABP assay that was not practical for clinical implementation. We aimed to validate the rule with an automated h-FABP assay that could be used clinically. In this prospective diagnostic cohort study we included patients presenting to the emergency department with suspected cardiac chest pain. Serum drawn on arrival was tested for h-FABP using an automated immunoturbidimetric assay (Randox) and high sensitivity troponin T (Roche). The primary outcome, a diagnosis of acute myocardial infarction (AMI), was adjudicated based on 12 h troponin testing. A secondary outcome, major adverse cardiac events (MACE; death, AMI, revascularisation or new coronary stenosis), was determined at 30 days. Of the 456 patients included, 78 (17.1%) had AMI and 97 (21.3%) developed MACE. Using the automated h-FABP assay, the MACS rule had the same C-statistic for MACE as the original rule (0.91; 95% CI 0.88 to 0.92). 18.9% of patients were identified as 'very low risk' and thus eligible for immediate discharge with no missed AMIs and a 2.3% incidence of MACE (n=2, both coronary stenoses). 11.1% of patients were classed as 'high-risk' and had a 92.0% incidence of MACE. Our findings validate the performance of a refined MACS rule incorporating an automated h-FABP assay, facilitating use in clinical settings. The effectiveness of this refined rule should be verified in an interventional trial prior to implementation. UK CRN 8376. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  4. High sensitive radiation detector for radiology dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Valente, M.; Malano, F. [Instituto de Fisica Enrique Gaviola, Oficina 102 FaMAF - UNC, Av. Luis Medina Allende, Ciudad Universitaria, 5000 Cordoba (Argentina); Molina, W.; Vedelago, J., E-mail: valente@famac.unc.edu.ar [Laboratorio de Investigaciones e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Laboratorio 448 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina)

    2014-08-15

    Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, dose rate recorded and incident direction independence as well as linear dose response. This work presents the development and characterization of a novel Fricke gel system, based on modified chemical compositions making possible its application in clinical radiology. Properties of standard Fricke gel dosimeter for high dose levels are used as starting point and suitable chemical modifications are introduced and carefully investigated in order to attain high resolution for low dose ranges, like those corresponding to radiology interventions. The developed Fricke gel radiation dosimeter system achieves the expected typical dose dependency, actually showing linear response in the dose range from 20 up to 4000 mGy. Systematic investigations including several chemical compositions are carried out in order to obtain a good enough dosimeter response for low dose levels. A suitable composition among those studied is selected as a good candidate for low dose level radiation dosimetry consisting on a modified Fricke solution fixed to a gel matrix containing benzoic acid along with sulfuric acid, ferrous sulfate, xylenol orange and ultra-pure reactive grade water. Dosimeter samples are prepared in standard vials for its in phantom irradiation and further characterization by spectrophotometry measuring visible light transmission and absorbance before and after irradiation. Samples are irradiated by typical kV X-ray tubes and calibrated Farmer type ionization chamber is used as reference to measure dose rates inside phantoms in at vials locations. Once sensitive material composition is already optimized, dose-response curves show significant improvement regarding overall sensitivity for low dose levels. According to

  5. High sensitive radiation detector for radiology dosimetry

    International Nuclear Information System (INIS)

    Valente, M.; Malano, F.; Molina, W.; Vedelago, J.

    2014-08-01

    Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, dose rate recorded and incident direction independence as well as linear dose response. This work presents the development and characterization of a novel Fricke gel system, based on modified chemical compositions making possible its application in clinical radiology. Properties of standard Fricke gel dosimeter for high dose levels are used as starting point and suitable chemical modifications are introduced and carefully investigated in order to attain high resolution for low dose ranges, like those corresponding to radiology interventions. The developed Fricke gel radiation dosimeter system achieves the expected typical dose dependency, actually showing linear response in the dose range from 20 up to 4000 mGy. Systematic investigations including several chemical compositions are carried out in order to obtain a good enough dosimeter response for low dose levels. A suitable composition among those studied is selected as a good candidate for low dose level radiation dosimetry consisting on a modified Fricke solution fixed to a gel matrix containing benzoic acid along with sulfuric acid, ferrous sulfate, xylenol orange and ultra-pure reactive grade water. Dosimeter samples are prepared in standard vials for its in phantom irradiation and further characterization by spectrophotometry measuring visible light transmission and absorbance before and after irradiation. Samples are irradiated by typical kV X-ray tubes and calibrated Farmer type ionization chamber is used as reference to measure dose rates inside phantoms in at vials locations. Once sensitive material composition is already optimized, dose-response curves show significant improvement regarding overall sensitivity for low dose levels. According to

  6. High-Sensitivity C-Reactive Protein as a Predictor of Cardiovascular Events after ST-Elevation Myocardial Infarction

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Daniel Rios Pinto; Ramos, Adriane Monserrat; Vieira, Pedro Lima; Menti, Eduardo; Bordin, Odemir Luiz Jr.; Souza, Priscilla Azambuja Lopes de; Quadros, Alexandre Schaan de; Portal, Vera Lúcia, E-mail: veraportal.pesquisa@gmail.com [Programa de Pós-Graduação em Ciências da Saúde: Cardiologia - Instituto de Cardiologia/Fundação Universitária de Cardiologia, Porto Alegre, RS (Brazil)

    2014-07-15

    The association between high-sensitivity C-reactive protein and recurrent major adverse cardiovascular events (MACE) in patients with ST-elevation myocardial infarction who undergo primary percutaneous coronary intervention remains controversial. To investigate the potential association between high-sensitivity C-reactive protein and an increased risk of MACE such as death, heart failure, reinfarction, and new revascularization in patients with ST-elevation myocardial infarction treated with primary percutaneous coronary intervention. This prospective cohort study included 300 individuals aged >18 years who were diagnosed with ST-elevation myocardial infarction and underwent primary percutaneous coronary intervention at a tertiary health center. An instrument evaluating clinical variables and the Thrombolysis in Myocardial Infarction (TIMI) and Global Registry of Acute Coronary Events (GRACE) risk scores was used. High-sensitivity C-reactive protein was determined by nephelometry. The patients were followed-up during hospitalization and up to 30 days after infarction for the occurrence of MACE. Student's t, Mann-Whitney, chi-square, and logistic regression tests were used for statistical analyses. P values of ≤0.05 were considered statistically significant. The mean age was 59.76 years, and 69.3% of patients were male. No statistically significant association was observed between high-sensitivity C-reactive protein and recurrent MACE (p = 0.11). However, high-sensitivity C-reactive protein was independently associated with 30-day mortality when adjusted for TIMI [odds ratio (OR), 1.27; 95% confidence interval (CI), 1.07-1.51; p = 0.005] and GRACE (OR, 1.26; 95% CI, 1.06-1.49; p = 0.007) risk scores. Although high-sensitivity C-reactive protein was not predictive of combined major cardiovascular events within 30 days after ST-elevation myocardial infarction in patients who underwent primary angioplasty and stent implantation, it was an independent predictor

  7. Cardiac involvement in canine babesiosis : review article

    Directory of Open Access Journals (Sweden)

    R.G. Lobetti

    2005-06-01

    Full Text Available Cardiac dysfunction in canine babesiosis has traditionally been regarded as a rare complication, with the majority of lesions reported as incidental findings at post-mortem examination. Recent studies have, however, demonstrated cardiac lesions in canine babesiosis. Cardiac troponins, especially troponin I, are sensitive markers of myocardial injury in canine babesiosis, and the magnitude of elevation of plasma troponin I concentrations appears to be proportional to the severity of the disease. ECG changes in babesiosis are similar to the pattern described for myocarditis and myocardial ischaemia and together with histopathological findings indicate that the heart suffers from the same pathological processes described in other organs in canine babesiosis, namely inflammation and hypoxia. The clinical application of the ECG appears to be limited and thus cardiovascular assessment should be based on functional monitoring rather than an ECG tracing. On cardiac histopathology from dogs that succumbed to babesiosis, haemorrhage, necrosis, inflammation and fibrin microthrombi in the myocardium were documented, all of which would have resulted in ECG changes and elevations in cardiac troponin. Myocardial damage causes left ventricular failure, which will result in hypotension and an expansion of the plasma volume due to homeostatic mechanisms.

  8. Quality and sensitivity of high-resolution numerical simulation of urban heat islands

    Science.gov (United States)

    Li, Dan; Bou-Zeid, Elie

    2014-05-01

    High-resolution numerical simulations of the urban heat island (UHI) effect with the widely-used Weather Research and Forecasting (WRF) model are assessed. Both the sensitivity of the results to the simulation setup, and the quality of the simulated fields as representations of the real world, are investigated. Results indicate that the WRF-simulated surface temperatures are more sensitive to the planetary boundary layer (PBL) scheme choice during nighttime, and more sensitive to the surface thermal roughness length parameterization during daytime. The urban surface temperatures simulated by WRF are also highly sensitive to the urban canopy model (UCM) used. The implementation in this study of an improved UCM (the Princeton UCM or PUCM) that allows the simulation of heterogeneous urban facets and of key hydrological processes, together with the so-called CZ09 parameterization for the thermal roughness length, significantly reduce the bias (Changing UCMs and PBL schemes does not alter the performance of WRF in reproducing bulk boundary layer temperature profiles significantly. The results illustrate the wide range of urban environmental conditions that various configurations of WRF can produce, and the significant biases that should be assessed before inferences are made based on WRF outputs. The optimal set-up of WRF-PUCM developed in this paper also paves the way for a confident exploration of the city-scale impacts of UHI mitigation strategies in the companion paper (Li et al 2014).

  9. Risk stratification in non-ST elevation acute coronary syndromes: Risk scores, biomarkers and clinical judgment

    Directory of Open Access Journals (Sweden)

    David Corcoran

    2015-09-01

    Clinical guidelines recommend an early invasive strategy in higher risk NSTE-ACS. The Global Registry of Acute Coronary Events (GRACE risk score is a validated risk stratification tool which has incremental prognostic value for risk stratification compared with clinical assessment or troponin testing alone. In emergency medicine, there has been a limited adoption of the GRACE score in some countries (e.g. United Kingdom, in part related to a delay in obtaining timely blood biochemistry results. Age makes an exponential contribution to the GRACE score, and on an individual patient basis, the risk of younger patients with a flow-limiting culprit coronary artery lesion may be underestimated. The future incorporation of novel cardiac biomarkers into this diagnostic pathway may allow for earlier treatment stratification. The cost-effectiveness of the new diagnostic pathways based on high-sensitivity troponin and copeptin must also be established. Finally, diagnostic tests and risk scores may optimize patient care but they cannot replace patient-focused good clinical judgment.

  10. High-precision high-sensitivity clock recovery circuit for a mobile payment application

    International Nuclear Information System (INIS)

    Sun Lichong; Yan Na; Min Hao; Ren Wenliang

    2011-01-01

    This paper presents a fully integrated carrier clock recovery circuit for a mobile payment application. The architecture is based on a sampling-detection module and a charge pump phase locked loop. Compared with clock recovery in conventional 13.56 MHz transponders, this circuit can recover a high-precision consecutive carrier clock from the on/off keying (OOK) signal sent by interrogators. Fabricated by a SMIC 0.18-μm EEPROM CMOS process, this chip works from a single power supply as low as 1.5 V Measurement results show that this circuit provides 0.34% frequency deviation and 8 mV sensitivity. (semiconductor integrated circuits)

  11. High efficiency solid-state sensitized heterojunction photovoltaic device

    KAUST Repository

    Wang, Mingkui

    2010-06-01

    The high molar extinction coefficient heteroleptic ruthenium dye, NaRu(4,4′-bis(5-(hexylthio)thiophen-2-yl)-2,2′-bipyridine) (4-carboxylic acid-4′-carboxylate-2,2′-bipyridine) (NCS) 2, exhibits certified 5% electric power conversion efficiency at AM 1.5 solar irradiation (100 mW cm-2) in a solid-state dye-sensitized solar cell using 2,2′,7,7′-tetrakis-(N,N-di-pmethoxyphenylamine)-9, 9′-spirobifluorene (spiro-MeOTAD) as the organic hole-transporting material. This demonstration elucidates a class of photovoltaic devices with potential for low-cost power generation. © 2010 Elsevier Ltd. All rights reserved.

  12. High efficiency solid-state sensitized heterojunction photovoltaic device

    KAUST Repository

    Wang, Mingkui; Liu, Jingyuan; Cevey-Ha, Ngoc-Le; Moon, Soo-Jin; Liska, Paul; Humphry-Baker, Robin; Moser, Jacques-E.; Grä tzel, Carole; Wang, Peng; Zakeeruddin, Shaik M.

    2010-01-01

    The high molar extinction coefficient heteroleptic ruthenium dye, NaRu(4,4′-bis(5-(hexylthio)thiophen-2-yl)-2,2′-bipyridine) (4-carboxylic acid-4′-carboxylate-2,2′-bipyridine) (NCS) 2, exhibits certified 5% electric power conversion efficiency at AM 1.5 solar irradiation (100 mW cm-2) in a solid-state dye-sensitized solar cell using 2,2′,7,7′-tetrakis-(N,N-di-pmethoxyphenylamine)-9, 9′-spirobifluorene (spiro-MeOTAD) as the organic hole-transporting material. This demonstration elucidates a class of photovoltaic devices with potential for low-cost power generation. © 2010 Elsevier Ltd. All rights reserved.

  13. High Sensitive pH Sensor Based on AlInN/GaN Heterostructure Transistor

    Directory of Open Access Journals (Sweden)

    Yan Dong

    2018-04-01

    Full Text Available The AlInN/GaN high-electron-mobility-transistor (HEMT indicates better performances compared with the traditional AlGaN/GaN HEMTs. The present work investigated the pH sensor functionality of an analogous HEMT AlInN/GaN device with an open gate. It was shown that the Al0.83In0.17N/GaN device demonstrates excellent pH sense functionality in aqueous solutions, exhibiting higher sensitivity (−30.83 μA/pH for AlInN/GaN and −4.6 μA/pH for AlGaN/GaN and a faster response time, lower degradation and good stability with respect to the AlGaN/GaN device, which is attributed to higher two-dimensional electron gas (2DEG density and a thinner barrier layer in Al0.83In0.17N/GaN owning to lattice matching. On the other hand, the open gate geometry was found to affect the pH sensitivity obviously. Properly increasing the width and shortening the length of the open gate area could enhance the sensitivity. However, when the open gate width is too larger or too small, the pH sensitivity would be suppressed conversely. Designing an optimal ratio of the width to the length is important for achieving high sensitivity. This work suggests that the AlInN/GaN-based 2DEG carrier modulated devices would be good candidates for high-performance pH sensors and other related applications.

  14. High Sensitive pH Sensor Based on AlInN/GaN Heterostructure Transistor.

    Science.gov (United States)

    Dong, Yan; Son, Dong-Hyeok; Dai, Quan; Lee, Jun-Hyeok; Won, Chul-Ho; Kim, Jeong-Gil; Chen, Dunjun; Lee, Jung-Hee; Lu, Hai; Zhang, Rong; Zheng, Youdou

    2018-04-24

    The AlInN/GaN high-electron-mobility-transistor (HEMT) indicates better performances compared with the traditional AlGaN/GaN HEMTs. The present work investigated the pH sensor functionality of an analogous HEMT AlInN/GaN device with an open gate. It was shown that the Al 0.83 In 0.17 N/GaN device demonstrates excellent pH sense functionality in aqueous solutions, exhibiting higher sensitivity (−30.83 μA/pH for AlInN/GaN and −4.6 μA/pH for AlGaN/GaN) and a faster response time, lower degradation and good stability with respect to the AlGaN/GaN device, which is attributed to higher two-dimensional electron gas (2DEG) density and a thinner barrier layer in Al 0.83 In 0.17 N/GaN owning to lattice matching. On the other hand, the open gate geometry was found to affect the pH sensitivity obviously. Properly increasing the width and shortening the length of the open gate area could enhance the sensitivity. However, when the open gate width is too larger or too small, the pH sensitivity would be suppressed conversely. Designing an optimal ratio of the width to the length is important for achieving high sensitivity. This work suggests that the AlInN/GaN-based 2DEG carrier modulated devices would be good candidates for high-performance pH sensors and other related applications.

  15. Towards sensitive, high-throughput, biomolecular assays based on fluorescence lifetime

    Science.gov (United States)

    Ioanna Skilitsi, Anastasia; Turko, Timothé; Cianfarani, Damien; Barre, Sophie; Uhring, Wilfried; Hassiepen, Ulrich; Léonard, Jérémie

    2017-09-01

    Time-resolved fluorescence detection for robust sensing of biomolecular interactions is developed by implementing time-correlated single photon counting in high-throughput conditions. Droplet microfluidics is used as a promising platform for the very fast handling of low-volume samples. We illustrate the potential of this very sensitive and cost-effective technology in the context of an enzymatic activity assay based on fluorescently-labeled biomolecules. Fluorescence lifetime detection by time-correlated single photon counting is shown to enable reliable discrimination between positive and negative control samples at a throughput as high as several hundred samples per second.

  16. Resonance analysis of a high temperature piezoelectric disc for sensitivity characterization.

    Science.gov (United States)

    Bilgunde, Prathamesh N; Bond, Leonard J

    2018-07-01

    Ultrasonic transducers for high temperature (200 °C+) applications are a key enabling technology for advanced nuclear power systems and in a range of chemical and petro-chemical industries. Design, fabrication and optimization of such transducers using piezoelectric materials remains a challenge. In this work, experimental data-based analysis is performed to investigate the fundamental causal factors for the resonance characteristics of a piezoelectric disc at elevated temperatures. The effect of all ten temperature-dependent piezoelectric constants (ε 33 , ε 11 , d 33 , d 31 , d 15 , s 11 , s 12 , s 13 , s 33 , s 44 ) is studied numerically on both the radial and thickness mode resonances of a piezoelectric disc. A sensitivity index is defined to quantify the effect of each of the temperature-dependent coefficients on the resonance modes of the modified lead zirconium titanate disc. The temperature dependence of s 33 showed highest sensitivity towards the thickness resonance mode followed by ε 33 , s 11 , s 13 , s 12 , d 31 , d 33 , s 44 , ε 11 , and d 15 in the decreasing order of the sensitivity index. For radial resonance modes, the temperature dependence of ε 33 showed highest sensitivity index followed by s 11 , s 12 and d 31 coefficient. This numerical study demonstrates that the magnitude of d 33 is not the sole factor that affects the resonance characteristics of the piezoelectric disc at high temperatures. It appears that there exists a complex interplay between various temperature dependent piezoelectric coefficients that causes reduction in the thickness mode resonance frequencies which is found to be agreement in with the experimental data at an elevated temperature. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Evaluation of C-reactive protein, Haptoglobin and cardiac troponin 1 levels in brachycephalic dogs with upper airway obstructive syndrome

    Directory of Open Access Journals (Sweden)

    Planellas Marta

    2012-08-01

    Full Text Available Abstract Background Brachycephalic dogs have unique upper respiratory anatomy with abnormal breathing patterns similar to those in humans with obstructive sleep apnea syndrome (OSAS. The objective of this study was to evaluate the correlation between anatomical components, clinical signs and several biomarkers, used to determine systemic inflammation and myocardial damage (C-reactive protein, CRP; Haptoglobin, Hp; cardiac troponin I, cTnI, in dogs with brachycephalic upper airway obstructive syndrome (BAOS. Results Fifty brachycephalic dogs were included in the study and the following information was studied: signalment, clinical signs, thoracic radiographs, blood work, ECG, components of BAOS, and CRP, Hp and cTnI levels. A high proportion of dogs with BAOS (88% had gastrointestinal signs. The prevalence of anatomic components of BAOS was: elongated soft palate (100%, stenotic nares (96%, everted laryngeal saccules (32% and tracheal hypoplasia (29.1%. Increased serum levels of biomarkers were found in a variable proportion of dogs: 14% (7/50 had values of CRP > 20 mg/L, 22.9% (11/48 had values of Hp > 3 g/L and 47.8% (22/46 had levels of cTnI > 0.05 ng/dl. Dogs with everted laryngeal saccules had more severe respiratory signs (p Conclusions According to the low percentage of patients with elevated levels of CRP and Hp, BAOS does not seem to cause an evident systemic inflammatory status. Some degree of myocardial damage may occur in dogs with BAOS that can be detected by cTnI concentration.

  18. Can a Point-of-Care Troponin I Assay be as Good as a Central Laboratory Assay? A MIDAS Investigation.

    Science.gov (United States)

    Peacock, W Frank; Diercks, Deborah; Birkhahn, Robert; Singer, Adam J; Hollander, Judd E; Nowak, Richard; Safdar, Basmah; Miller, Chadwick D; Peberdy, Mary; Counselman, Francis; Chandra, Abhinav; Kosowsky, Joshua; Neuenschwander, James; Schrock, Jon; Lee-Lewandrowski, Elizabeth; Arnold, William; Nagurney, John

    2016-09-01

    We aimed to compare the diagnostic accuracy of the Alere Triage Cardio3 Tropinin I (TnI) assay (Alere, Inc., USA) and the PathFast cTnI-II (Mitsubishi Chemical Medience Corporation, Japan) against the central laboratory assay Singulex Erenna TnI assay (Singulex, USA). Using the Markers in the Diagnosis of Acute Coronary Syndromes (MIDAS) study population, we evaluated the ability of three different assays to identify patients with acute myocardial infarction (AMI). The MIDAS dataset, described elsewhere, is a prospective multicenter dataset of emergency department (ED) patients with suspected acute coronary syndrome (ACS) and a planned objective myocardial perfusion evaluation. Myocardial infarction (MI) was diagnosed by central adjudication. The C-statistic with 95% confidence intervals (CI) for diagnosing MI by using a common population (n=241) was 0.95 (0.91-0.99), 0.95 (0.91-0.99), and 0.93 (0.89-0.97) for the Triage, Singulex, and PathFast assays, respectively. Of samples with detectable troponin, the absolute values had high Pearson (R(P)) and Spearman (R(S)) correlations and were R(P)=0.94 and R(S)=0.94 for Triage vs Singulex, R(P)=0.93 and R(S)=0.85 for Triage vs PathFast, and R(P)=0.89 and R(S)=0.73 for PathFast vs Singulex. In a single comparative population of ED patients with suspected ACS, the Triage Cardio3 TnI, PathFast, and Singulex TnI assays provided similar diagnostic performance for MI.

  19. Highly-sensitive and large-dynamic diffuse optical tomography system for breast tumor detection

    Science.gov (United States)

    Du, Wenwen; Zhang, Limin; Yin, Guoyan; Zhang, Yanqi; Zhao, Huijuan; Gao, Feng

    2018-02-01

    Diffuse optical tomography (DOT) as a new functional imaging has important clinical applications in many aspects such as benign and malignant breast tumor detection, tumor staging and so on. For quantitative detection of breast tumor, a three-wavelength continuous-wave DOT prototype system combined the ultra-high sensitivity of the photon-counting detection and the measurement parallelism of the lock-in technique was developed to provide high temporal resolution, high sensitivity, large dynamic detection range and signal-to-noise ratio. Additionally, a CT-analogous scanning mode was proposed to cost-effectively increase the detection data. To evaluate the feasibility of the system, a series of assessments were conducted. The results demonstrate that the system can obtain high linearity, stability and negligible inter-wavelength crosstalk. The preliminary phantom experiments show the absorption coefficient is able to be successfully reconstructed, indicating that the system is one of the ideal platforms for optical breast tumor detection.

  20. High sensitivity tests of the standard model for electroweak interactions

    International Nuclear Information System (INIS)

    1994-01-01

    The work done on this project focused on two LAMPF experiments. The MEGA experiment is a high-sensitivity search for the lepton family number violating decay μ → eγ to a sensitivity which, measured in terms of the branching ratio, BR = [μ → eγ]/[μ eν μ ν e ] ∼ 10 -13 , will be over two orders of magnitude better than previously reported values. The second is a precision measurement of the Michel ρ parameter from the positron energy spectrum of μ → eν μ ν e to test the predictions V-A theory of weak interactions. In this experiment the uncertainty in the measurement of the Michel ρ parameter is expected to be a factor of three lower than the present reported value. The detectors are operational, and data taking has begun

  1. Accelerated Sensitivity Analysis in High-Dimensional Stochastic Reaction Networks.

    Science.gov (United States)

    Arampatzis, Georgios; Katsoulakis, Markos A; Pantazis, Yannis

    2015-01-01

    Existing sensitivity analysis approaches are not able to handle efficiently stochastic reaction networks with a large number of parameters and species, which are typical in the modeling and simulation of complex biochemical phenomena. In this paper, a two-step strategy for parametric sensitivity analysis for such systems is proposed, exploiting advantages and synergies between two recently proposed sensitivity analysis methodologies for stochastic dynamics. The first method performs sensitivity analysis of the stochastic dynamics by means of the Fisher Information Matrix on the underlying distribution of the trajectories; the second method is a reduced-variance, finite-difference, gradient-type sensitivity approach relying on stochastic coupling techniques for variance reduction. Here we demonstrate that these two methods can be combined and deployed together by means of a new sensitivity bound which incorporates the variance of the quantity of interest as well as the Fisher Information Matrix estimated from the first method. The first step of the proposed strategy labels sensitivities using the bound and screens out the insensitive parameters in a controlled manner. In the second step of the proposed strategy, a finite-difference method is applied only for the sensitivity estimation of the (potentially) sensitive parameters that have not been screened out in the first step. Results on an epidermal growth factor network with fifty parameters and on a protein homeostasis with eighty parameters demonstrate that the proposed strategy is able to quickly discover and discard the insensitive parameters and in the remaining potentially sensitive parameters it accurately estimates the sensitivities. The new sensitivity strategy can be several times faster than current state-of-the-art approaches that test all parameters, especially in "sloppy" systems. In particular, the computational acceleration is quantified by the ratio between the total number of parameters over the

  2. Accelerated Sensitivity Analysis in High-Dimensional Stochastic Reaction Networks.

    Directory of Open Access Journals (Sweden)

    Georgios Arampatzis

    Full Text Available Existing sensitivity analysis approaches are not able to handle efficiently stochastic reaction networks with a large number of parameters and species, which are typical in the modeling and simulation of complex biochemical phenomena. In this paper, a two-step strategy for parametric sensitivity analysis for such systems is proposed, exploiting advantages and synergies between two recently proposed sensitivity analysis methodologies for stochastic dynamics. The first method performs sensitivity analysis of the stochastic dynamics by means of the Fisher Information Matrix on the underlying distribution of the trajectories; the second method is a reduced-variance, finite-difference, gradient-type sensitivity approach relying on stochastic coupling techniques for variance reduction. Here we demonstrate that these two methods can be combined and deployed together by means of a new sensitivity bound which incorporates the variance of the quantity of interest as well as the Fisher Information Matrix estimated from the first method. The first step of the proposed strategy labels sensitivities using the bound and screens out the insensitive parameters in a controlled manner. In the second step of the proposed strategy, a finite-difference method is applied only for the sensitivity estimation of the (potentially sensitive parameters that have not been screened out in the first step. Results on an epidermal growth factor network with fifty parameters and on a protein homeostasis with eighty parameters demonstrate that the proposed strategy is able to quickly discover and discard the insensitive parameters and in the remaining potentially sensitive parameters it accurately estimates the sensitivities. The new sensitivity strategy can be several times faster than current state-of-the-art approaches that test all parameters, especially in "sloppy" systems. In particular, the computational acceleration is quantified by the ratio between the total number of

  3. Comparison of pre- and post-levothyroxine high-sensitivity c-reactive protein and fetuin-a levels in subclinical hypothyroidism

    Directory of Open Access Journals (Sweden)

    Oktay Bilgir

    2015-02-01

    Full Text Available OBJECTIVE: The objective of this trial was to determine the levels of inflammatory markers, high-sensitivity C-reactive protein and fetuin-A pre- and post-levothyroxine treatment in cases of subclinical hypothyroidism. MATERIALS AND METHODS: A total of 32 patients with a diagnosis of subclinical hypothyroidism and a control group of 30 healthy individuals were tested for high-sensitivity C-reactive protein and fetuin-A, followed by the administration of 50 µg of levothyroxine in the patient group for 3 months. During the post-treatment stage, high-sensitivity C-reactive protein and fetuin-A levels in the patient group were re-assessed and compared with pre-treatment values. RESULTS: Pre-treatment levels of both high-sensitivity C-reactive protein and fetuin-A were observed to be higher in the patient group than in the control group. The decrease in high-sensitivity C-reactive protein levels during the post-treatment stage was not statistically significant. However, the decrease observed in post-treatment fetuin-A levels was found to be statistically significant. CONCLUSION: The decrease in fetuin-A levels in subclinical hypothyroidism cases indicates that levothyroxine treatment exerts anti-inflammatory and anti-apoptotic effects. Although the decrease in high-sensitivity C-reactive protein levels was statistically non-significant, it is predicted to reach significance with sustained treatment.

  4. Highly sensitive glucose sensor based on monodisperse palladium nickel/activated carbon nanocomposites.

    Science.gov (United States)

    Koskun, Yağmur; Şavk, Aysun; Şen, Betül; Şen, Fatih

    2018-06-20

    Glucose enzyme biosensors have been used for a variety of applications such as medical diagnosis, bioprocess engineering, beverage industry and environmental scanning etc. and there is still a growing interest in glucose sensors. For this purpose, addressed herein, as a novel glucose sensor, highly sensitive activated carbon (AC) decorated monodisperse nickel and palladium alloy nanocomposites modified glassy carbon electrode (Ni-Pd@AC/GCE NCs) have been synthesized by in-situ reduction technique. Raman Spectroscopy (RS), X-ray Photoelectron Spectroscopy (XPS), X-ray Diffraction (XRD), Transmission Electron Microscopy (TEM), cyclic voltammetry (CV) and chronoamperometry (CA) were used for the characterization of the prepared non-enzymatic glucose sensor. The characteristic sensor properties of the Ni-Pd@AC/GCE electrode were compared with Ni-Pd NCs/GCE, Ni@AC/GCE and Pd@AC/GCE and the results demonstrate that the AC is very effective in the enhancement of the electrocatalytic properties of sensor. In addition, the Ni-Pd@AC/GCE nanocomposites showed a very low detection limit of 0.014 μM, a wide linear range of 0.01 mM-1 mM and a very high sensitivity of 90 mA mM -1  cm -2 . Furthermore, the recommended sensor offer the various advantageous such as facile preparation, fast response time, high selectivity and sensitivity. Lastly, monodisperse Ni-Pd@AC/GCE was utilized to detect glucose in real sample species. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Rational clinical evaluation of suspected acute coronary syndromes: The value of more information.

    Science.gov (United States)

    Hancock, David G; Chuang, Ming-Yu Anthony; Bystrom, Rebecca; Halabi, Amera; Jones, Rachel; Horsfall, Matthew; Cullen, Louise; Parsonage, William A; Chew, Derek P

    2017-12-01

    Many meta-analyses have provided synthesised likelihood ratio data to aid clinical decision-making. However, much less has been published on how to safely combine clinical information in practice. We aimed to explore the benefits and risks of pooling clinical information during the ED assessment of suspected acute coronary syndrome. Clinical information on 1776 patients was collected within a randomised trial conducted across five South Australian EDs between July 2011 and March 2013. Bayes theorem was used to calculate patient-specific post-test probabilities using age- and gender-specific pre-test probabilities and likelihood ratios corresponding to the presence or absence of 18 clinical factors. Model performance was assessed as the presence of adverse cardiac outcomes among patients theoretically discharged at a post-test probability less than 1%. Bayes theorem-based models containing high-sensitivity troponin T (hs-troponin) outperformed models excluding hs-troponin, as well as models utilising TIMI and GRACE scores. In models containing hs-troponin, a plateau in improving discharge safety was observed after the inclusion of four clinical factors. Models with fewer clinical factors better approximated the true event rate, tended to be safer and resulted in a smaller standard deviation in post-test probability estimates. We showed that there is a definable point where additional information becomes uninformative and may actually lead to less certainty. This evidence supports the concept that clinical decision-making in the assessment of suspected acute coronary syndrome should be focused on obtaining the least amount of information that provides the highest benefit for informing the decisions of admission or discharge. © 2017 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  6. Sensitizing effects of NOx on CH4 oxidation at high pressure

    DEFF Research Database (Denmark)

    Rasmussen, Christian Lund; Rasmussen, Anja Egede; Glarborg, Peter

    2008-01-01

    The CH4/O2/NOx system is investigated in a laboratory-scale high pressure laminar flow reactor with the purpose of elucidating the sensitizing effects of NOx on CH4 oxidation at high pressures and medium temperatures. Experiments are conducted at 100, 50, and 20 bar, 600-900 K, and stoichiometric...... ratios ranging from highly reducing to oxidizing conditions. The experimental results are interpreted in terms of a detailed kinetic model drawn from previous work of the authors, including an updated reaction subset for the direct interactions of NOx and C1-2 hydrocarbon species relevant...

  7. High sensitivity MOSFET-based neutron dosimetry

    International Nuclear Information System (INIS)

    Fragopoulou, M.; Konstantakos, V.; Zamani, M.; Siskos, S.; Laopoulos, T.; Sarrabayrouse, G.

    2010-01-01

    A new dosemeter based on a metal-oxide-semiconductor field effect transistor sensitive to both neutrons and gamma radiation was manufactured at LAAS-CNRS Laboratory, Toulouse, France. In order to be used for neutron dosimetry, a thin film of lithium fluoride was deposited on the surface of the gate of the device. The characteristics of the dosemeter, such as the dependence of its response to neutron dose and dose rate, were investigated. The studied dosemeter was very sensitive to gamma rays compared to other dosemeters proposed in the literature. Its response in thermal neutrons was found to be much higher than in fast neutrons and gamma rays.

  8. Investigation of high sensitivity radio-frequency readout circuit based on AlGaN/GaN high electron mobility transistor

    International Nuclear Information System (INIS)

    Zhang Xiao-Yu; Sun Jian-Dong; Li Xin-Xing; Zhou Yu; Lü Li; Qin Hua; Tan Ren-Bing

    2015-01-01

    An AlGaN/GaN high electron mobility transistor (HEMT) device is prepared by using a semiconductor nanofabrication process. A reflective radio-frequency (RF) readout circuit is designed and the HEMT device is assembled in an RF circuit through a coplanar waveguide transmission line. A gate capacitor of the HEMT and a surface-mounted inductor on the transmission line are formed to generate LC resonance. By tuning the gate voltage V g , the variations of gate capacitance and conductance of the HEMT are reflected sensitively from the resonance frequency and the magnitude of the RF reflection signal. The aim of the designed RF readout setup is to develop a highly sensitive HEMT-based detector. (paper)

  9. High sensitivity thermal sensors on insulating diamond

    Energy Technology Data Exchange (ETDEWEB)

    Job, R. [Fernuniversitaet Hagen (Gesamthochschule) (Germany). Electron. Devices; Denisenko, A.V. [Fernuniversitaet Hagen (Gesamthochschule) (Germany). Electron. Devices; Zaitsev, A.M. [Fernuniversitaet Hagen (Gesamthochschule) (Germany). Electron. Devices; Melnikov, A.A. [Belarussian State Univ., Minsk (Belarus). HEII and FD; Werner, M. [VDI/VDE-IT, Teltow (Germany); Fahrner, W.R. [Fernuniversitaet Hagen (Gesamthochschule) (Germany). Electron. Devices

    1996-12-15

    Diamond is a promising material to develop sensors for applications in harsh environments. To increase the sensitivity of diamond temperature sensors the effect of thermionic hole emission (TE) over an energetic barrier formed in the interface between highly boron-doped p-type and intrinsic insulating diamond areas has been suggested. To study the TE of holes a p-i-p diode has been fabricated and analyzed by electrical measurements in the temperature range between 300 K and 700 K. The experimental results have been compared with numerical simulations of its electrical characteristics. Based on a model of the thermionic emission of carriers into an insulator it has been suggested that the temperature sensitivity of the p-i-p diode on diamond is strongly affected by the re-emission of holes from a group of donor-like traps located at a level of 0.7-1.0 eV above the valence band. The mechanism of thermal activation of the current includes a spatial redistribution of the potential, which results in the TE regime from a decrease of the immobilized charge of the ionized traps within the i-zone of the diode and the correspondent lowering of the forward biased barrier. The characteristics of the p-i-p diode were studied with regard to temperature sensor applications. The temperature coefficient of resistance (TCR=-0.05 K{sup -1}) for temperatures above 600 K is about four times larger than the maximal attainable TCR for conventional boron-doped diamond resistors. (orig.)

  10. High frequency electrical stimulation concurrently induces central sensitization and ipsilateral inhibitory pain modulation.

    Science.gov (United States)

    Vo, L; Drummond, P D

    2013-03-01

    In healthy humans, analgesia to blunt pressure develops in the ipsilateral forehead during various forms of limb pain. The aim of the current study was to determine whether this analgesic response is induced by ultraviolet B radiation (UVB), which evokes signs of peripheral sensitization, or by high-frequency electrical stimulation (HFS), which triggers signs of central sensitization. Before and after HFS and UVB conditioning, sensitivity to heat and to blunt and sharp stimuli was assessed at and adjacent to the treated site in the forearm. In addition, sensitivity to blunt pressure was measured bilaterally in the forehead. The effect of ipsilateral versus contralateral temple cooling on electrically evoked pain in the forearm was then examined, to determine whether HFS or UVB conditioning altered inhibitory pain modulation. UVB conditioning triggered signs of peripheral sensitization, whereas HFS conditioning triggered signs of central sensitization. Importantly, ipsilateral forehead analgesia developed after HFS but not UVB conditioning. In addition, decreases in electrically evoked pain at the HFS-treated site were greater during ipsilateral than contralateral temple cooling, whereas decreases at the UVB-treated site were similar during both procedures. HFS conditioning induced signs of central sensitization in the forearm and analgesia both in the ipsilateral forehead and the HFS-treated site. This ipsilateral analgesia was not due to peripheral sensitization or other non-specific effects, as it failed to develop after UVB conditioning. Thus, the supra-spinal mechanisms that evoke central sensitization might also trigger a hemilateral inhibitory pain modulation process. This inhibitory process could sharpen the boundaries of central sensitization or limit its spread. © 2012 European Federation of International Association for the Study of Pain Chapters.

  11. Cardiac Troponin T and Hydration Status as Prognostic Markers in Hemodialysis Patients.

    Science.gov (United States)

    Hoppe, Krzysztof; Schwermer, Krzysztof; Klysz, Patrycja; Radziszewska, Dorota; Sawatiuk, Peter; Baum, Ewa; Kaczmarek, Jolanta; Roszak, Magdalena; Kaluzna, Malgorzata; Lindholm, Bengt; Pawlaczyk, Krzysztof; Oko, Andrzej

    2015-01-01

    This study aimed to assess cardiac troponin T (cTnT) and hydration state as cardiovascular (CV) risk markers in hemodialysis (HD) patients. Two hundred and forty one patients were divided according to HD vintage into two groups: SV (HD ≤24 months) and LV. Water balance was assessed with overhydration (OH%; bioimpedance analysis) and daily diuresis (DD); CV dysfunction with cTnT and heart ultrasound; nutrition with subjective global assessment (SGA), cholesterol (TC) and albumin. SV had lower OH% (2.8 vs. 3.5, p < 0.05) and higher DD (1,161 vs. 637 ml, p < 0.001), while LV had higher cTnT (0.1 ± 0.04 vs. 0.1 ± 0.07 ng/ml, p < 0.05) and lower interventricular septum thickness (IVS; 13.4 vs. 14.5 mm, p < 0.05). Nutritional state as reflected by lower TC was worse in LV (184.7 vs. 169.5 mg/dl, p < 0.05). Mortality was higher in patients in the LV group (15 vs. 27 deaths, p < 0.05). OH% correlated inversely with albumin (r = -0.36, p < 0.001), TC (r = -0.31, p < 0.001) and cTnT (r = -0.4, p < 0.001). cTnT correlated positively with IVS (r = 0.39, p < 0.001), SGA (r = 0.23, p = 0.001) and mortality rate (r = 0.21, p < 0.01), and negatively with DD (r = -0.34, p < 0.001) and albumin (r = -0.25, p < 0.001). Longer dialysis vintage associates with CV dysfunction, overhydration and increased mortality, which may be predicted with OH% and cTnT. Video Journal Club ‘Cappuccino with Claudio Ronco' at http://www.karger.com/?doi=376603.

  12. High Sensitivity Refractometer Based on TiO2-Coated Adiabatic Tapered Optical Fiber via ALD Technology

    Science.gov (United States)

    Zhu, Shan; Pang, Fufei; Huang, Sujuan; Zou, Fang; Guo, Qiang; Wen, Jianxiang; Wang, Tingyun

    2016-01-01

    Atomic layer deposition (ALD) technology is introduced to fabricate a high sensitivity refractometer based on an adiabatic tapered optical fiber. Different thicknesses of titanium dioxide (TiO2) nanofilm were coated around the tapered fiber precisely and uniformly under different deposition cycles. Attributed to the higher refractive index of the TiO2 nanofilm compared to that of silica, an asymmetric Fabry–Perot (F-P) resonator could be constructed along the fiber taper. The central wavelength of the F-P resonator could be controlled by adjusting the thickness of the TiO2 nanofilm. Such a F-P resonator is sensitive to changes in the surrounding refractive index (SRI), which is utilized to realize a high sensitivity refractometer. The refractometer developed by depositing 50.9-nm-thickness TiO2 on the tapered fiber shows SRI sensitivity as high as 7096 nm/RIU in the SRI range of 1.3373–1.3500. Due to TiO2’s advantages of high refractive index, lack of toxicity, and good biocompatibility, this refractometer is expected to have wide applications in the biochemical sensing field. PMID:27537885

  13. Development of a High-Sensitivity Wireless Accelerometer for Structural Health Monitoring.

    Science.gov (United States)

    Zhu, Li; Fu, Yuguang; Chow, Raymond; Spencer, Billie F; Park, Jong Woong; Mechitov, Kirill

    2018-01-17

    Structural health monitoring (SHM) is playing an increasingly important role in ensuring the safety of structures. A shift of SHM research away from traditional wired methods toward the use of wireless smart sensors (WSS) has been motivated by the attractive features of wireless smart sensor networks (WSSN). The progress achieved in Micro Electro-Mechanical System (MEMS) technologies and wireless data transmission, has extended the effectiveness and range of applicability of WSSNs. One of the most common sensors employed in SHM strategies is the accelerometer; however, most accelerometers in WSS nodes have inadequate resolution for measurement of the typical accelerations found in many SHM applications. In this study, a high-resolution and low-noise tri-axial digital MEMS accelerometer is incorporated in a next-generation WSS platform, the Xnode. In addition to meeting the acceleration sensing demands of large-scale civil infrastructure applications, this new WSS node provides powerful hardware and a robust software framework to enable edge computing that can deliver actionable information. Hardware and software integration challenges are presented, and the associate resolutions are discussed. The performance of the wireless accelerometer is demonstrated experimentally through comparison with high-sensitivity wired accelerometers. This new high-sensitivity wireless accelerometer will extend the use of WSSN to a broader class of SHM applications.

  14. Development of a High-Sensitivity Wireless Accelerometer for Structural Health Monitoring

    Science.gov (United States)

    Zhu, Li; Fu, Yuguang; Chow, Raymond; Spencer, Billie F.; Park, Jong Woong; Mechitov, Kirill

    2018-01-01

    Structural health monitoring (SHM) is playing an increasingly important role in ensuring the safety of structures. A shift of SHM research away from traditional wired methods toward the use of wireless smart sensors (WSS) has been motivated by the attractive features of wireless smart sensor networks (WSSN). The progress achieved in Micro Electro-Mechanical System (MEMS) technologies and wireless data transmission, has extended the effectiveness and range of applicability of WSSNs. One of the most common sensors employed in SHM strategies is the accelerometer; however, most accelerometers in WSS nodes have inadequate resolution for measurement of the typical accelerations found in many SHM applications. In this study, a high-resolution and low-noise tri-axial digital MEMS accelerometer is incorporated in a next-generation WSS platform, the Xnode. In addition to meeting the acceleration sensing demands of large-scale civil infrastructure applications, this new WSS node provides powerful hardware and a robust software framework to enable edge computing that can deliver actionable information. Hardware and software integration challenges are presented, and the associate resolutions are discussed. The performance of the wireless accelerometer is demonstrated experimentally through comparison with high-sensitivity wired accelerometers. This new high-sensitivity wireless accelerometer will extend the use of WSSN to a broader class of SHM applications. PMID:29342102

  15. High-speed asynchronous optical sampling for high-sensitivity detection of coherent phonons

    International Nuclear Information System (INIS)

    Dekorsy, T; Taubert, R; Hudert, F; Schrenk, G; Bartels, A; Cerna, R; Kotaidis, V; Plech, A; Koehler, K; Schmitz, J; Wagner, J

    2007-01-01

    A new optical pump-probe technique is implemented for the investigation of coherent acoustic phonon dynamics in the GHz to THz frequency range which is based on two asynchronously linked femtosecond lasers. Asynchronous optical sampling (ASOPS) provides the performance of on all-optical oscilloscope and allows us to record optically induced lattice dynamics over nanosecond times with femtosecond resolution at scan rates of 10 kHz without any moving part in the set-up. Within 1 minute of data acquisition time signal-to-noise ratios better than 10 7 are achieved. We present examples of the high-sensitivity detection of coherent phonons in superlattices and of the coherent acoustic vibration of metallic nanoparticles

  16. High sensitivity optical fiber liquid level sensor based on a compact MMF-HCF-FBG structure

    Science.gov (United States)

    Zhang, Yunshan; Zhang, Weigang; Chen, Lei; Zhang, Yanxin; Wang, Song; Yan, Tieyi

    2018-05-01

    An ultra-high sensitivity fiber liquid level sensor based on wavelength demodulation is proposed and demonstrated. The sensor is composed of a segment of multimode fiber and a large aperture hollow-core fiber assisted by a fiber Bragg grating (FBG). Interference occurs due to core mismatching and different modes with different effective refractive indices. The experimental results show that the liquid level sensitivity of the sensor is 1.145 nm mm‑1, and the linearity is up to 0.996. The dynamic temperature compensation of the sensor can be achieved by cascading an FBG. Considering the high sensitivity and compact structure of the sensor, it can be used for real-time intelligent monitoring of tiny changes in liquid level.

  17. A self-amplified transistor immunosensor under dual gate operation: highly sensitive detection of hepatitis B surface antigen

    Science.gov (United States)

    Lee, I.-K.; Jeun, M.; Jang, H.-J.; Cho, W.-J.; Lee, K. H.

    2015-10-01

    Ion-sensitive field-effect transistors (ISFETs), although they have attracted considerable attention as effective immunosensors, have still not been adopted for practical applications owing to several problems: (1) the poor sensitivity caused by the short Debye screening length in media with high ion concentration, (2) time-consuming preconditioning processes for achieving the highly-diluted media, and (3) the low durability caused by undesirable ions such as sodium chloride in the media. Here, we propose a highly sensitive immunosensor based on a self-amplified transistor under dual gate operation (immuno-DG ISFET) for the detection of hepatitis B surface antigen. To address the challenges in current ISFET-based immunosensors, we have enhanced the sensitivity of an immunosensor by precisely tailoring the nanostructure of the transistor. In the pH sensing test, the immuno-DG ISFET showed superior sensitivity (2085.53 mV per pH) to both standard ISFET under single gate operation (58.88 mV per pH) and DG ISFET with a non-tailored transistor (381.14 mV per pH). Moreover, concerning the detection of hepatitis B surface antigens (HBsAg) using the immuno-DG ISFET, we have successfully detected trace amounts of HBsAg (22.5 fg mL-1) in a non-diluted 1× PBS medium with a high sensitivity of 690 mV. Our results demonstrate that the proposed immuno-DG ISFET can be a biosensor platform for practical use in the diagnosis of various diseases.Ion-sensitive field-effect transistors (ISFETs), although they have attracted considerable attention as effective immunosensors, have still not been adopted for practical applications owing to several problems: (1) the poor sensitivity caused by the short Debye screening length in media with high ion concentration, (2) time-consuming preconditioning processes for achieving the highly-diluted media, and (3) the low durability caused by undesirable ions such as sodium chloride in the media. Here, we propose a highly sensitive immunosensor

  18. Cardiac Troponin and Creatine Kinase Response to the Three Modes of Training (Running, Pedaling and Swimming in Young Girls

    Directory of Open Access Journals (Sweden)

    Abbas Saremi

    2016-04-01

    Full Text Available Abstract Background: Cardiac troponin T and creatine kinase are used as biological markers for cardiomyocytes and its levels in serum are used as indicators of myocardial cell injury. The purpose of this study was to compare the effects of 3 different training protocols (runing, swimming, and pedaling training on myocardial cell injury biomarkers in young girls. Materials and Methods: In this semi-experimental study with pretest–posttest design, ten healthy young girls (aged 23.0±1.6 y were selected in a convenience sampling way. The subjects performed three types of exercise in 7 days interval. Blood sample was assessed before and after the exercise sessions. Data were analyzed using t-test and analysis of variance. Results: Our results indicated that creatin kinase increased significantly after three types of exercise (p0.05. Conclusion: Our data suggest that intensive exercise is associated with cardiac damage in less trained girls and the type of exercise is determinants of the magnitude of myocardial injury biomarkers release.

  19. Use of resting myocardial scintigraphy during chest pain to exclude diagnosis of acute myocardial infarction

    International Nuclear Information System (INIS)

    Barbirato, Gustavo Borges; Azevedo, Jader Cunha de; Felix, Renata Christian Martins; Correa, Patricia Lavatori; Volschan, Andre; Viegas, Monica; Pimenta, Lucia; Dohmann, Hans Fernando Rocha; Mesquita, Evandro Tinoco; Mesquita, Claudio Tinoco

    2009-01-01

    Background: Images of myocardial perfusion taken during an episode of chest pain have been used for patients in the emergency department. Objective: To evaluate the operating characteristics of 99m Tc-Tetrofosmin scintigraphy during an episode of chest pain to exclude the diagnosis of cute myocardial infarction. Methods: One hundred and eight patients admitted with chest pain, or up to four hours after the end of symptoms and non diagnostic electrocardiogram, underwent resting scintigraphy and measurement of troponin I concentrations. Patients with a history of myocardial infarction (MI) were not excluded (24 patients). Troponin I concentrations were determined at admission and 6 hours later. Nuclear physicians performed a blind analysis of the images, and myocardial infarction was confirmed whenever troponin I level increase was three times that of the control. Results: Resting perfusion image was abnormal in all 6 patients with MI. Only 1 patient had a normal image and increased troponin levels. Fifty-five patients had positive images without MI, and 46 patients had normal images and troponin levels. The prevalence of the disease was 6.5%. The sensitivity and specificity of the resting images during an episode of chest pain to diagnose MI was 85.7% and 45.5%, respectively. The negative predictive value was 97.7%. Conclusion: Patients undergoing chest pain protocol with SPECT showed an excellent negative predictive value to exclude diagnosis of myocardial infarction. These results suggest that resting perfusion image is an important tool at the chest pain unit. (author)

  20. A Flexible and Highly Sensitive Piezoresistive Pressure Sensor Based on Micropatterned Films Coated with Carbon Nanotubes

    Directory of Open Access Journals (Sweden)

    Jia-lin Yao

    2016-01-01

    Full Text Available Excellent flexibility, high sensitivity, and low consumption are essential characteristics in flexible microtube pressure sensing occasion, for example, implantable medical devices, industrial pipeline, and microfluidic chip. This paper reports a flexible, highly sensitive, and ultrathin piezoresistive pressure sensor for fluid pressure sensing, whose sensing element is micropatterned films with conductive carbon nanotube layer. The flexible pressure sensor, the thickness of which is 40 ± 10 μm, could be economically fabricated by using biocompatible polydimethylsiloxane (PDMS. Experimental results show that the flexible pressure sensor has high sensitivity (0.047 kPa−1 in gas sensing and 5.6 × 10−3 kPa−1 in liquid sensing and low consumption (<180 μW, and the sensor could be used to measure the pressure in curved microtubes.