WorldWideScience

Sample records for high sensitive optical

  1. Highly Sensitive Optical Receivers

    CERN Document Server

    Schneider, Kerstin

    2006-01-01

    Highly Sensitive Optical Receivers primarily treats the circuit design of optical receivers with external photodiodes. Continuous-mode and burst-mode receivers are compared. The monograph first summarizes the basics of III/V photodetectors, transistor and noise models, bit-error rate, sensitivity and analog circuit design, thus enabling readers to understand the circuits described in the main part of the book. In order to cover the topic comprehensively, detailed descriptions of receivers for optical data communication in general and, in particular, optical burst-mode receivers in deep-sub-µm CMOS are presented. Numerous detailed and elaborate illustrations facilitate better understanding.

  2. High sensitivity optically pumped quantum magnetometer.

    Science.gov (United States)

    Tiporlini, Valentina; Alameh, Kamal

    2013-01-01

    Quantum magnetometers based on optical pumping can achieve sensitivity as high as what SQUID-based devices can attain. In this paper, we discuss the principle of operation and the optimal design of an optically pumped quantum magnetometer. The ultimate intrinsic sensitivity is calculated showing that optimal performance of the magnetometer is attained with an optical pump power of 20 μW and an operation temperature of 48°C. Results show that the ultimate intrinsic sensitivity of the quantum magnetometer that can be achieved is 327 fT/Hz(½) over a bandwidth of 26 Hz and that this sensitivity drops to 130 pT/Hz(½) in the presence of environmental noise. The quantum magnetometer is shown to be capable of detecting a sinusoidal magnetic field of amplitude as low as 15 pT oscillating at 25 Hz.

  3. Highly Sensitive Electro-Optic Modulators

    Energy Technology Data Exchange (ETDEWEB)

    DeVore, Peter S [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-10-26

    There are very important diagnostic and communication applications that receive faint electrical signals to be transmitted over long distances for capture. Optical links reduce bandwidth and distance restrictions of metal transmission lines; however, such signals are only weakly imprinted onto the optical carrier, resulting in low fidelity transmission. Increasing signal fidelity often necessitates insertion of radio-frequency (RF) amplifiers before the electro-optic modulator, but (especially at high frequencies) RF amplification results in large irreversible distortions. We have investigated the feasibility of a Sensitive and Linear Modulation by Optical Nonlinearity (SALMON) modulator to supersede RF-amplified modulators. SALMON uses cross-phase modulation, a manifestation of the Kerr effect, to enhance the modulation depth of an RF-modulated optical wave. This ultrafast process has the potential to result in less irreversible distortions as compared to a RF-amplified modulator due to the broadband nature of the Kerr effect. Here, we prove that a SALMON modulator is a feasible alternative to an RFamplified modulator, by demonstrating a sensitivity enhancement factor greater than 20 and significantly reduced distortion.

  4. High-sensitivity fiber optic acoustic sensors

    Science.gov (United States)

    Lu, Ping; Liu, Deming; Liao, Hao

    2016-11-01

    Due to the overwhelming advantages compared with traditional electronicsensors, fiber-optic acoustic sensors have arisen enormous interest in multiple disciplines. In this paper we present the recent research achievements of our group on fiber-optic acoustic sensors. The main point of our research is high sensitivity interferometric acoustic sensors, including Michelson, Sagnac, and Fabry-Pérot interferometers. In addition, some advanced technologies have been proposed for acoustic or acoustic pressure sensing such as single-mode/multimode fiber coupler, dual FBGs and multi-longitudinal mode fiber laser based acoustic sensors. Moreover, our attention we have also been paid on signal demodulation schemes. The intensity-based quadrature point (Q-point) demodulation, two-wavelength quadrature demodulation and symmetric 3×3 coupler methodare discussed and compared in this paper.

  5. A highly sensitive optical detector for use in deep underwater.

    Science.gov (United States)

    Hanada, H.; Hayashino, T.; Ito, M.; Iwasaki, A.; Kawamorita, K.; Kawamoto, H.; Matsumoto, T.; Narita, S.; Takayama, T.; Tanaka, S.; Yamaguchi, A.; Aoki, T.; Mitsui, K.; Ohashi, Y.; Okada, A.; Fukawa, M.; Uehara, S.; Bolesta, J. W.; Gorham, P. W.; Kondo, S.; Learned, J. G.; Matsuno, S.; Mignard, M.; Mitiguy, R.; O'Connor, D. J.; Peterson, V. Z.; Roberts, A.; Rosen, M.; Stenger, V. J.; Takemori, D.; Wilkins, G.; Grieder, P. K. F.; Minkowski, P.; Kitamura, T.; Camerini, U.; Grogan, W.; Jaworski, M.; March, R.; Narita, T.; Nicklaus, D.

    1998-05-01

    The authors have developed an optical detector module for use in deep underwater experiments that will search for high-energy neutrinos from cosmic rays and astronomical sources. This module is sensitive to single photons, is operable under high pressure, functions automatically and is remotely controlled.

  6. Highly sensitive optical sensor system for blood leakage detection

    Science.gov (United States)

    Ueda, Masahiro; Ishikawa, Kazuhiko; Jie, Chen; Sanae, Mizuno; Touma, Yasunori

    A highly sensitive method for the detection of blood leakage has been developed, and a practical sensor system for blood concentration measurement has been constructed. The present method is based on the attenuation of laser light by blood cells. The effects of the fluctuations of the incident laser light power are eliminated by normalizing the attenuated light intensity by the incident light intensity. A part of the incident laser light is reflected by a beam splitter mounted at the entrance of the test cell, of which the power is measured to provide base data for normalization. The optical path is extended to enhance sensitivity by using a pair of side mirrors. This multi-reflection method is very effective to increase sensitivity; the maximum sensitivity obtained for blood concentration is about 4 X 10 -6 by volume, which is significantly higher than that of the conventional sensors.

  7. High Sensitivity Polymer Optical Fiber-Bragg-Grating-Based Accelerometer

    DEFF Research Database (Denmark)

    Stefani, Alessio; Andresen, Søren; Yuan, Wu

    2012-01-01

    We report on the fabrication and characterization of the first accelerometer based on a polymer optical fiber Bragg grating (FBG) for operation at both 850 and 1550 nm. The devices have a flat frequency response over a 1-kHz bandwidth and a resonance frequency of about 3 kHz. The response is linear...... up to at least 15 g and sensitivities as high as 19 pm/g (shift in resonance wavelength per unit acceleration) have been demonstrated. Given that 15 g corresponds to a strain of less than 0.02% and that polymer fibers have an elastic limit of more than 1%, the polymer FBG accelerometer can measure...... very strong accelerations. We compare with corresponding silica FBG accelerometers and demonstrate that using polymer FBGs improves the sensitivity by more than a factor of four and increases the figure of merit, defined as the sensitivity times the resonance frequency squared....

  8. High-sensitive scanning laser magneto-optical imaging system.

    Science.gov (United States)

    Murakami, Hironaru; Tonouchi, Masayoshi

    2010-01-01

    A high-sensitive scanning laser magneto-optical (MO) imaging system has been developed. The system is mainly composed of a laser source, galvano meters, and a high-sensitive differential optical-detector. Preliminary evaluation of system performance by using a Faraday indicator with a Faraday rotation coefficient of 3.47 x 10(-5) rad/microm Oe shows a magnetic sensitivity of about 5 microT, without any need for accumulation or averaging processing. Using the developed MO system we have succeeded in the fast and quantitative imaging of a rotationally symmetric magnetic field distribution around an YBa(2)Cu(3)O(7-delta) (YBCO) strip line applied with dc-biased current, and also succeeded in the detection of quantized fine signals corresponding to magnetic flux quantum generation in a superconducting loop of an YBCO Josephson vortex flow transistor. Thus, the developed system enables us not only to do fast imaging and local signal detection but also to directly evaluate both the strength and direction of a magnetic signal.

  9. Cavity Enhanced Optical Vernier Spectroscopy, Broad Band, High Resolution, High Sensitivity

    CERN Document Server

    Gohle, Christoph; Schliesser, Albert; Udem, Thomas; Hänsch, Theodor W

    2007-01-01

    A femtosecond frequency comb provides a vast number of equidistantly spaced narrow band laser modes that can be simultaneously tuned and frequency calibrated with 15 digits accuracy. Our Vernier spectrometer utilizes all of theses modes in a massively parallel manner to rapidly record both absorption and dispersion spectra with a sensitivity that is provided by a high finesse broad band optical resonator and a resolution that is only limited by the frequency comb line width while keeping the required setup simple.

  10. Photon Counting System for High-Sensitivity Detection of Bioluminescence at Optical Fiber End.

    Science.gov (United States)

    Iinuma, Masataka; Kadoya, Yutaka; Kuroda, Akio

    2016-01-01

    The technique of photon counting is widely used for various fields and also applicable to a high-sensitivity detection of luminescence. Thanks to recent development of single photon detectors with avalanche photodiodes (APDs), the photon counting system with an optical fiber has become powerful for a detection of bioluminescence at an optical fiber end, because it allows us to fully use the merits of compactness, simple operation, highly quantum efficiency of the APD detectors. This optical fiber-based system also has a possibility of improving the sensitivity to a local detection of Adenosine triphosphate (ATP) by high-sensitivity detection of the bioluminescence. In this chapter, we are introducing a basic concept of the optical fiber-based system and explaining how to construct and use this system.

  11. High-sensitive Optical Pulse-Shape Characterization using a Beating-Contrast-Measurement Technique

    CERN Document Server

    Roncin, Vincent; Millaud, Audrey; Cramer, Romain; Jaouën, Yves; Simon, Jean-Claude

    2014-01-01

    Ultrahigh-speed optical transmission technology, such as optical time domain multiplexing or optical signal processing is a key point for increasing the communication capacity. The system performances are strongly related to pulse properties. We present an original method dedicated to short pulse-shape characterization with high repetition rate using standard optical telecommunications equipments. Its principle is based on temporal measurement of the contrast produced by the beating of two delayed optical pulses in a high bandwidth photo detector. This technique returns firstly reliable information on the pulse-shape, such as pulse width, shape and pedestal. Simulation and experimental results evaluate the high-sensitivity and the high-resolution of the technique allowing the measurement of pulse extinction ratio up to 20 dB with typical timing resolution of about 100 fs. The compatibility of the technique with high repetition rate pulse measurement offers an efficient tool for short pulse analysis.

  12. High Sensitivity Detection of ATP Using Bioluminescence at An Optical Fiber End

    Science.gov (United States)

    Iinuma, Masataka; Ushio, Yasuaki; Kuroda, Akio; Kadoya, Yutaka

    We investigated the sensitivity of ATP detection based on bioluminescence at an optical fiber end where luciferase molecules were immobilized via silica-binding protein molecules. Luminescence was detected by an avalanche photo diode (APD), with coupling optics to make full use of the merit of compactness, high quantum efficiency and low noise of the APD. The core diameter and the numerical aperture of the optical fiber, as well as the design of the coupling optics, were optimized so as to realize high photon-collection efficiency. A detection limit of about 10-10 M was obtained, which corresponds to 10-15 mol of ATP. A rough estimation shows that the photon count rate is still two orders of magnitude lower than that limited by diffusion or reaction processes, implying a possibility of further improvement of the sensitivity.

  13. Highly sensitive fluorescence detection of avidin/streptavidin with an optical interference mirror slide.

    Science.gov (United States)

    Yasuda, Mitsuru; Akimoto, Takuo

    2012-01-01

    This paper presents highly sensitive fluorescence detections of avidin and streptavidin using an optical interference mirror (OIM) slide consisting of a plane mirror covered with an optical interference layer. Compared with a common glass slide, the OIM slide can enhance the fluorescence from a dye by more than 100-fold. We fabricated an OIM slide by depositing an optical interference layer of Al(2)O(3) on an Ag mirror. To enhance the fluorescence maximally, the optimal thickness of the Al(2)O(3) layer was estimated from optical interference theory. For detections of protein, avidin/streptavidin labeled with fluorescein, Cy3, and Cy5 were detected with biotin immobilized on an OIM slide with the optimal Al(2)O(3) thickness. We achieved a sensitivity improvement of more than 50-fold, comparing with a glass slide. Such a high degree of improvement would be a significant contribution to further progress in biomedical research and medical diagnostics.

  14. A high sensitive fiber-optic strain sensor with tunable temperature sensitivity for temperature-compensation measurement

    Science.gov (United States)

    Hu, Jie; Huang, Hui; Bai, Min; Zhan, Tingting; Yang, Zhibo; Yu, Yan; Qu, Bo

    2017-02-01

    A high sensitive fiber-optic strain sensor, which consists of a cantilever, a tandem rod and a fiber collimator, was proposed. The tandem rod, which transfer the applied strain to the cantilever, was used for tuning the temperature sensitivity from ‑0.15 to 0.19 dB/°C via changing the length ratio of the rods. Moreover, due to the small beam divergence of the collimator, high strain sensitivity can be realized via incident-angle sensitive detection-mechanism. A strain detection-range of 1.1 × 103 με (with a sensing length of 21.5 mm), a detection limit of 5.7 × 10‑3 με, and a maximum operating frequency of 1.18 KHz were demonstrated. This sensor is promising for compensating the thermal-expansion of various target objects.

  15. Label-free biosensing with high sensitivity in dual-core microstructured polymer optical fibers

    DEFF Research Database (Denmark)

    Markos, Christos; Yuan, Wu; Vlachos, Kyriakos

    2011-01-01

    We present experimentally feasible designs of a dual-core microstructured polymer optical fiber (mPOF), which can act as a highly sensitive, label-free, and selective biosensor. An immobilized antigen sensing layer on the walls of the holes in the mPOF provides the ability to selectively capture...

  16. Optical Properties of High Sensitivity Fiber Bragg Grating on Temperature Sensor

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    In this paper, the spectrum shift properties of the center reflection wavelength detected to be based on the FBG sensor with ambient temperature change. The basic theoretical methods and numerical simulation for the spectral properties of uniform Bragg grating is analyzed by using coupling mode theory which is optical properties of high sensitivity fiber Bragg grating on temperature sensor in accordance with experiment.

  17. Project Title: Radiochemical Analysis by High Sensitivity Dual-Optic Micro X-ray Fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Havrilla, George J.; Gao, Ning

    2003-06-01

    A novel dual-optic micro X-ray fluorescence instrument will be developed to do radiochemical analysis of high-level radioactive wastes at DOE sites such as Savannah River Site and Hanford. This concept incorporates new X-ray optical elements such as monolithic polycapillaries, which focus X-rays. The polycapillary optic can be used to focus X-rays emitted by the X-ray tube thereby increasing the X-ray flux on the sample over 1000 times. The polycapillary optic will also be used to collect the X-rays from the excitation site. This will effectively screen the radiation background from the radioactive species in the specimen. This dual-optic approach significantly reduces the background and increases the analyte signal thereby increasing the sensitivity of the analysis. This dual-capillary design is essentially a confocal (having the same foci) design, i.e. the detected X-rays are only emitted from the overlap of the two focal spots. This increases spatial resolution and reduce s background. The integration of the X-ray optics increases the signal-to-noise and thereby increases the sensitivity of the analysis for low-level analytes. This work will address a key need for radiochemical analysis of high-level waste using a non-destructive, multi-element, and rapid method in a radiation environment. There is significant potential that this instrumentation could be capable of on-line analysis for process waste stream characterization at DOE sites.

  18. Radiochemical Analysis by High Sensitivity Dual-Optic Micro X-ray Fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Havrilla, George J.; Gao, Ning

    2004-06-01

    A novel dual-optic micro X-ray fluorescence instrument will be developed to do radiochemical analysis of high-level radioactive wastes at DOE sites such as Savannah River Site and Hanford. This concept incorporates new X-ray optical elements such as monolithic polycapillaries, which focus X-rays. The polycapillary optic can be used to focus X-rays emitted by the X-ray tube thereby increasing the X-ray flux on the sample over 1000 times. The polycapillary optic will also be used to collect the X-rays from the excitation site. This will effectively screen the radiation background from the radioactive species in the specimen. This dual-optic approach significantly reduces the background and increases the analyte signal thereby increasing the sensitivity of the analysis. This dual-capillary design is essentially a confocal (having the same foci) design, i.e. the detected X-rays are only emitted from the overlap of the two focal spots. This increases spatial resolution and reduces background. The integration of the X-ray optics increases the signal-to-noise and thereby increases the sensitivity of the analysis for low-level analytes. This work will address a key need for radiochemical analysis of high-level waste using a non-destructive, multi-element, and rapid method in a radiation environment. There is significant potential that this instrumentation could be capable of on-line analysis for process waste stream characterization at DOE sites.

  19. A novel fiber optic geophone with high sensitivity for geo-acoustic detection

    Science.gov (United States)

    Zhang, Zhenhui; Yang, Huayong; Xiong, Shuidong; Luo, Hong; Cao, Chunyan; Ma, Shuqing

    2014-12-01

    A novel interferometric fiber optic geophone is introduced in this paper. This geophone is mainly used for geo-acoustic signal detection. The geophone use one of the three orthogonal components of mandrel type push-pull structure in mechanically and single-mode fiber optic Michelson interferometer structure with Faraday Rotation Mirror (FRM) elements in optically. The resonance frequency of the geophone is larger than 1000Hz. The acceleration sensitivity is as high as 56.6 dB (0dB re 1rad/g) with a slight sensitivity fluctuation of +/-0. 2dB within the frequency band from 20Hz to 200Hz. The geo-acoustic signals generated by underwater blasting are detected successfully. All the channels show good uniformity in the detected wave shape and the amplitudes exhibit very slight differences. The geo-acoustic signal excitated by the engine of surface vehicles was also detected successfully.

  20. Miniaturized Fiber-Optic Fabry-Perot Interferometer for Highly Sensitive Refractive Index Measurement

    Institute of Scientific and Technical Information of China (English)

    Ming Deng; Tao Zhu; Yun-Jiang Rao; Hong Li

    2008-01-01

    This paper presents a novel miniaturized fiber-optic Fabry-Peort interferometer (FPI) for highly sensitive refractive index measurement. This device was tested for the refractive indices of various liquids including acetone and ethanol at room temperature. The sensitivity for measurement of refractive index change of ethanol is 1138 nm/RIU at the wavelength of 1550 nm. In addition, the sensor fabrication is simple including only cleaving, splicing, and etching. The signal is stable with high visibility. Therefore, it provides a valuable tool in biological and chemical applications.

  1. Optical transitions in highly charged californium ions with high sensitivity to variation of the fine-structure constant.

    Science.gov (United States)

    Berengut, J C; Dzuba, V A; Flambaum, V V; Ong, A

    2012-08-17

    We study electronic transitions in highly charged Cf ions that are within the frequency range of optical lasers and have very high sensitivity to potential variations in the fine-structure constant, α. The transitions are in the optical range despite the large ionization energies because they lie on the level crossing of the 5f and 6p valence orbitals in the thallium isoelectronic sequence. Cf(16+) is a particularly rich ion, having several narrow lines with properties that minimize certain systematic effects. Cf(16+) has very large nuclear charge and large ionization energy, resulting in the largest α sensitivity seen in atomic systems. The lines include positive and negative shifters.

  2. High sensitivity resonance frequency measurements of individualmicro-cantilevers using fiber optical interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Duden, Thomas; Radmilovic, Velimir

    2009-03-04

    We describe a setup for the resonance frequency measurement of individual microcantilevers. The setup displays both high spatial selectivity and sensitivity to specimen vibrations by utilizing a tapered uncoated fiber tip. The high sensitivity to specimen vibrations is achieved by the combination of optical Fabry-Perot interferometry and narrow band RF detection. Wave fronts reflected on the specimen and on the fiber tip end face interfere, thus no reference plane on the specimen is needed, as demonstrated with the example of freestanding silicon nitride micro-cantilevers. The resulting system is integrated in a DB-235 dual beam FIB system, thereby allowing the measurement of micro-cantilever responses during observation in SEM mode. The FIB was used to modify the optical fiber tip. At this point of our RF system development, the microcantilevers used to characterize the detector were not modified in situ.

  3. High sensitivity electro-optic modulation of slow light in ellipse rods PC-CROW

    Science.gov (United States)

    Li, Changhong; Wan, Yong; Zong, Weihua

    2017-07-01

    A tunable slow light with low group velocity, high buffer performance and high sensitivity is realized in photonic crystal coupled resonator optical waveguide (PC-CROW) with elliptical rod around cavity. By adjusting the long axis and short axis of the elliptical rods, the slow light and buffer performance of PC-CROW are optimized. As ae=0.42a, be=0.20a, the group velocity is below 2.3053×10-4c, simultaneously, the buffer capacity C and delay time Ts reach the optimum value of 9.8214 bit and 354.8 ps. Then the dynamic modulation of the slow light and buffer performance based on this optimized structure has been discussed systematically. Thanks to the electro-optic effect of the polystyrene substrate, the guided mode shifts linearly to short wavelength in sensitivity of 3.0 nm/mV around 1550 nm, as the applied voltage increases. The modulation sensitivities of delay time and buffer capacity are 0.445 ns/mV and 0.051 bit/mV, respectively. These results show a considerable potential for this structure that can be dynamically controlled according to the practical requirements by electro-optic effect in PC-CROW.

  4. Stereo-SCIDAR: Optical turbulence profiling with high sensitivity using a modified SCIDAR instrument

    CERN Document Server

    Shepherd, H W; Wilson, R W; Butterley, T; Avila, R; Dhillon, V S; Morris, T J

    2013-01-01

    The next generation of adaptive optics (AO) systems will require tomographic reconstruction techniques to map the optical refractive index fluctuations, generated by the atmospheric turbulence, along the line of sight to the astronomical target. These systems can be enhanced with data from an external atmospheric profiler. This is important for Extremely Large Telescope scale tomography. Here we propose a new instrument which utilises the generalised SCIntillation Detection And Ranging (SCIDAR) technique to allow high sensitivity vertical profiles of the atmospheric optical turbulence and wind velocity profile above astronomical observatories. The new approach, which we refer to as 'Stereo-SCIDAR', uses a stereoscopic system with the scintillation pattern from each star of a double-star target incident on a separate detector. Separating the pupil images for each star has several advantages including: increased magnitude difference tolerance for the target stars; negating the need for re-calibration due to the...

  5. Project Title: Radiochemical Analysis by High Sensitivity Dual-Optic Micro X-ray Fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Havrilla, George J.; Gao, Ning

    2002-06-01

    A novel dual-optic micro X-ray fluorescence instrument will be developed to do radiochemical analysis of high-level radioactive wastes at DOE sites such as Savannah River Site and Hanford. This concept incorporates new X-ray optical elements such as monolithic polycapillaries and double bent crystals, which focus X-rays. The polycapillary optic can be used to focus X-rays emitted by the X-ray tube thereby increasing the X-ray flux on the sample over 1000 times. Polycapillaries will also be used to collect the X-rays from the excitation site and screen the radiation background from the radioactive species in the specimen. This dual-optic approach significantly reduces the background and increases the analyte signal thereby increasing the sensitivity of the analysis. A doubly bent crystal used as the focusing optic produces focused monochromatic X-ray excitation, which eliminates the bremsstrahlung background from the X-ray source. The coupling of the doubly bent crystal for monochromatic excitation with a polycapillary for signal collection can effectively eliminate the noise background and radiation background from the specimen. The integration of these X-ray optics increases the signal-to-noise and thereby increases the sensitivity of the analysis for low-level analytes. This work will address a key need for radiochemical analysis of high-level waste using a non-destructive, multi-element, and rapid method in a radiation environment. There is significant potential that this instrumentation could be capable of on-line analysis for process waste stream characterization at DOE sites.

  6. High sensitivity photonic time-stretch electro-optic sampling of terahertz pulses

    Science.gov (United States)

    Szwaj, C.; Evain, C.; Le Parquier, M.; Roy, P.; Manceron, L.; Brubach, J.-B.; Tordeux, M.-A.; Bielawski, S.

    2016-10-01

    Single-shot recording of terahertz electric signals has recently become possible at high repetition rates, by using the photonic time-stretch electro-optic sampling (EOS) technique. However the moderate sensitivity of time-stretch EOS is still a strong limit for a range of applications. Here we present a variant enabling to increase the sensitivity of photonic time-stretch for free-propagating THz signals. The ellipticity of the laser probe is enhanced by adding a set of Brewster plates, as proposed by Ahmed et al. [Rev. Sci. Instrum. 85, 013114 (2014)] in a different context. The method is tested using the high repetition rate terahertz coherent synchrotron radiation source of the SOLEIL synchrotron radiation facility. The signal-to-noise ratio of our terahertz digitizer could thus be straightforwardly improved by a factor ≈6.5, leading to a noise-equivalent input electric field below 1.25 V/cm inside the electro-optic crystal, over the 0-300 GHz band (i.e., 2.3 μ V / cm / √{ Hz } ). The sensitivity is scalable with respect to the available laser power, potentially enabling further sensitivity improvements when needed.

  7. High sensitivity contrast enhanced optical coherence tomography for functional in vivo imaging

    Science.gov (United States)

    Liba, Orly; SoRelle, Elliott D.; Sen, Debasish; de la Zerda, Adam

    2017-02-01

    In this study, we developed and applied highly-scattering large gold nanorods (LGNRs) and custom spectral detection algorithms for high sensitivity contrast-enhanced optical coherence tomography (OCT). We were able to detect LGNRs at a concentration as low as 50 pM in blood. We used this approach for noninvasive 3D imaging of blood vessels deep in solid tumors in living mice. Additionally, we demonstrated multiplexed imaging of spectrally-distinct LGNRs that enabled observations of functional drainage in lymphatic networks. This method, which we call MOZART, provides a platform for molecular imaging and characterization of tissue noninvasively at cellular resolution.

  8. High sensitivity photonic time-stretch electro-optic sampling of terahertz pulses

    CERN Document Server

    Szwaj, Christophe; Parquier, Marc Le; Roy, Pascale; Manceron, Laurent; Brubach, Jean-Blaise; Tordeux, Marie-Agnès; Bielawski, Serge

    2016-01-01

    Single-shot recording of terahertz electric signals has recently become possible at high repetition rates, by using the photonic time-stretch electro-optic sampling (EOS) technique. However the moderate sensitivity of time-stretch EOS is still a strong limit for a range of applications. Here we present a variant enabling to increase the sensitivity of photonic time-stretch for free-propagating THz signals. A key point is to integrate the idea presented in Ref. [Ahmed et al., Rev. Sci. Instrum. 85, 013114 (2014)], for upgrading classical time-stretch systems. The method is tested using the high repetition rate terahertz coherent synchrotron radiation source (CSR) of the SOLEIL synchrotron radiation facility. The signal-to-noise ratio of our terahertz digitizer could thus be straightforwardly improved by a factor $\\approx 6.5$, leading to a noise-equivalent input electric field below $1.25$~V/cm inside the electro-optic crystal, over the 0-300~GHz band (i.e, 2.3~$\\mu$V/cm/$\\sqrt{\\text{Hz}}$). The sensitivity is...

  9. Silicone rubber-coated highly sensitive optical fiber sensor for temperature measurement

    Science.gov (United States)

    Bhardwaj, Vanita; Gangwar, Rahul Kumar; Singh, Vinod Kumar

    2016-12-01

    A silicone rubber-coated Mach-Zehnder interferometer (MZI) is proposed and applied to temperature measurement. The MZI is fabricated by splicing single mode fiber between a short section of no-core fiber (NCF) and the ultra-abrupt taper region. The sensing length of MZI is coated with liquid silicone rubber to enhance the temperature sensitivity. Here, NCF is used to excite the higher order cladding mode, the ultra-abrupt taper region acts as a optical fiber coupler, and the silicone rubber coating on sensing length is used as solid cladding material instead of liquid. The enhancement of the sensitivity of a device is due to the high refractive index (1.42) and thermo-optic coefficient (-1.4×10-4/°C) of silicone rubber as compared to liquid cladding temperature sensors. The experiment was performed for both coated and uncoated MZI and the results were compared. The MZI exhibits a high temperature sensitivity of 253.75 and 121.26 pm/°C for coated and uncoated sensing probes, respectively, in the temperature range from 30°C to 75°C.

  10. High Sensitivity Refractometer Based on TiO₂-Coated Adiabatic Tapered Optical Fiber via ALD Technology.

    Science.gov (United States)

    Zhu, Shan; Pang, Fufei; Huang, Sujuan; Zou, Fang; Guo, Qiang; Wen, Jianxiang; Wang, Tingyun

    2016-08-15

    Atomic layer deposition (ALD) technology is introduced to fabricate a high sensitivity refractometer based on an adiabatic tapered optical fiber. Different thicknesses of titanium dioxide (TiO₂) nanofilm were coated around the tapered fiber precisely and uniformly under different deposition cycles. Attributed to the higher refractive index of the TiO₂ nanofilm compared to that of silica, an asymmetric Fabry-Perot (F-P) resonator could be constructed along the fiber taper. The central wavelength of the F-P resonator could be controlled by adjusting the thickness of the TiO₂ nanofilm. Such a F-P resonator is sensitive to changes in the surrounding refractive index (SRI), which is utilized to realize a high sensitivity refractometer. The refractometer developed by depositing 50.9-nm-thickness TiO₂ on the tapered fiber shows SRI sensitivity as high as 7096 nm/RIU in the SRI range of 1.3373-1.3500. Due to TiO₂'s advantages of high refractive index, lack of toxicity, and good biocompatibility, this refractometer is expected to have wide applications in the biochemical sensing field.

  11. High-refractive-index transparent coatings enhance the optical fiber cladding modes refractometric sensitivity.

    Science.gov (United States)

    Renoirt, Jean-Michel; Zhang, Chao; Debliquy, Marc; Olivier, Marie-Georges; Mégret, Patrice; Caucheteur, Christophe

    2013-11-18

    The high order cladding modes of standard single mode optical fiber appear in quasi-degenerate pairs corresponding to mostly radially or mostly azimuthally polarized light. In this work, we demonstrate that, in the presence of a high-refractive-index coating surrounding the fiber outer surface, the wavelength spacing between the orthogonally polarized cladding modes families can be drastically enhanced. This behavior can be advantageously exploited for refractometric sensing purposes. For this, we make use of tilted fiber Bragg gratings (TFBGs) as spectral combs to excite the orthogonally polarized cladding modes families separately. TFBGs were coated with a nanometer-scale transparent thin film characterized by a refractive index value close to 1.9, well higher than the one of pure silica. This coating brings two important assets: an ~8-fold increase in refractometric sensitivity is obtained in comparison to bare TFBGs while the sensitivity is extended to surrounding refractive index (SRI) values above 1.45.

  12. Highly sensitive detection of molecular interactions with plasmonic optical fiber grating sensors.

    Science.gov (United States)

    Voisin, Valérie; Pilate, Julie; Damman, Pascal; Mégret, Patrice; Caucheteur, Christophe

    2014-01-15

    Surface Plasmon resonance (SPR) optical fiber biosensors constitute a miniaturized counterpart to the bulky prism configuration and offer remote operation in very small volumes of analyte. They are a cost-effective and relatively straightforward technique to yield in situ (or even possibly in vivo) molecular detection. The biosensor configuration reported in this work uses nanometric-scale gold-coated tilted fiber Bragg gratings (TFBGs) interrogated by light polarized radially to the optical fiber outer surface, so as to maximize the optical coupling with the SPR. These gratings were recently associated to aptamers to assess their label-free biorecognition capability in buffer and serum solutions. In this work, using the well-acknowledged biotin-streptavidin pair as a benchmark, we go forward in the demonstration of their unique sensitivity. In addition to the monitoring of the self-assembled monolayer (SAM) in real time, we report an unprecedented limit of detection (LOD) as low as 2 pM. Finally, an immunosensing experiment is realized with human transferrin (dissociation constant Kd~10(-8) M(-1)). It allows to assess both the reversibility and the robustness of the SPR-TFBG biosensors and to confirm their high sensitivity.

  13. Compact, highly sensitive optical gyros and sensors with fast-light

    Science.gov (United States)

    Christensen, Caleb A.; Zavriyev, Anton; Cummings, Malcolm; Beal, A. C.; Lucas, Mark; Lagasse, Michael

    2015-09-01

    Fast-light phenomena can enhance the sensitivity of an optical gyroscope of a given size by several orders of magnitude, and could be applied to other optical sensors as well. MagiQ Technologies has been developing a compact fiber-based fast light Inertial Measurement Unit (IMU) using Stimulated Brillouin Scattering in optical fibers with commercially mature technologies. We will report on our findings, including repeatable fast-light effects in the lab, numerical analysis of noise and stability given realistic optical specs, and methods for optimizing efficiency, size, and reliability with current technologies. The technology could benefit inertial navigation units, gyrocompasses, and stabilization techniques, and could allow high grade IMUs in spacecraft, unmanned aerial vehicles or sensors, where the current size and weight of precision gyros are prohibitive. By using photonic integrated circuits and telecom-grade components along with specialty fibers, we also believe that our design is appropriate for development without further advances in the state of the art of components.

  14. Electro-optic comb based real time ultra-high sensitivity phase noise measurement system for high frequency microwaves.

    Science.gov (United States)

    Kuse, N; Fermann, M E

    2017-06-06

    Recent progress in ultra low phase noise microwave generation indispensably depends on ultra low phase noise characterization systems. However, achieving high sensitivity currently relies on time consuming averaging via cross correlation, which sometimes even underestimates phase noise because of residual correlations. Moreover, extending high sensitivity phase noise measurements to microwaves beyond 10 GHz is very difficult because of the lack of suitable high frequency microwave components. In this work, we introduce a delayed self-heterodyne method in conjunction with sensitivity enhancement via the use of higher order comb modes from an electro-optic comb for ultra-high sensitivity phase noise measurements. The method obviates the need for any high frequency RF components and has a frequency measurement range limited only by the bandwidth (100 GHz) of current electro-optic modulators. The estimated noise floor is as low as -133 dBc/Hz, -155 dBc/Hz, -170 dBc/Hz and -171 dBc/Hz without cross correlation at 1 kHz, 10 kHz, 100 kHz and 1 MHz Fourier offset frequency for a 10 GHz carrier, respectively. Moreover, since no cross correlation is necessary, RF oscillator phase noise can be directly suppressed via feedback up to 100 kHz frequency offset.

  15. High-sensitivity four-layer polymer fiber-optic evanescent wave sensor.

    Science.gov (United States)

    Xin, Xin; Zhong, Nianbing; Liao, Qiang; Cen, Yanyan; Wu, Ruohua; Wang, Zhengkun

    2017-05-15

    We present a novel four-layer structure consisting of bottom, second, third, and surface layers in the sensing region, for a D-shaped step-index fiber-optic evanescent wave (FOEW) sensor. To reduce the background noise, the surface of the longitudinal section in the D-shaped region is coated with a light-absorbing film. We check the morphologies of the second and surface layers, examine the refractive indices (RIs) of the third and surface layers, and analyze the composition of the surface layer. We also investigate the effects of the thicknesses and RIs of the third and surface layers and the LA film on the light transmission and sensitivity of the FOEW sensors. The results highlight the very good sensitivity of the proposed FOEW sensor with a four-layer structure, which reached -0.077 (μg/l)(-1) in the detection of the target antibody; the sensitivity of the novel FOEW sensor was 7.60 and 1.52 times better than that of a conventional sensor with a core-cladding structure and an FOEW sensor with a three-layer structure doped with GeO2. The applications of this high-sensitivity FOEW sensor can be extended to biodefense, disease diagnosis, and biomedical and biochemical analysis.

  16. A highly sensitive upconverting nano-glass-ceramic-based optical thermometer

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Daqin, E-mail: dqchen@hdu.edu.cn; Liu, Shen; Wan, Zhongyi; Chen, Yan, E-mail: chenyan@hdu.edu.cn

    2016-07-05

    Yb/Tm: YF{sub 3} nanoparticles embedded transparent bulk glass ceramic was successfully prepared to explore its possible application in optical temperature sensors. Specifically, owing to the competition of electron population in the thermally coupled Tm{sup 3+3}F{sub 2,3} and {sup 3}H{sub 4} excited states, two upconversion emission bands corresponding to Tm{sup 3+}: {sup 3}F{sub 2,3} → {sup 3}H{sub 6} transition and {sup 1}G{sub 4}→{sup 3}F{sub 4} one exhibited opposite temperature-dependent behaviors, which resulted in monotonous enhancement of the related fluorescence intensity ratio with increase of temperature. As a consequence, Tm{sup 3+} activators in the present YF{sub 3} glass ceramic had advantages of a high sensitivity of 1.84% per K, an avoidable spectral overlapping and a negligible thermal effect for accurate temperature detecting. - Highlights: • Yb/Tm: β-YF{sub 3} embedded transparent glass ceramic was fabricated. • Glass crystallization induced greatly enhancement of upconversion luminescence. • Different T-sensitive emission behaviors of two thermally coupled states were observed. • Tm{sup 3+} fluorescence intensity ratio intensified with increase of temperature. • The glass ceramic exhibited a high sensitivity of 1.84% K{sup −1} and a negligible thermal effect.

  17. Highly Sensitive Fiber-Optic Faraday-Effect Magnetic Field Sensor Based on Yttrium Iron Garnet

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The principle and performance of a fiber-optic Faraday-effect magnetic-field sensor based on an yttrium iron garnet (YIG) and two flux concentrations are described. A single polarization maintaining optical fiber links the sensor head to the source and detection system, in which the technique of phase shift cancellation is used to cancel the phase shift that accumulate in the optical fiber. Flux concentrators were exploited to enhance the YIG crystal magneto optic sensitivity .The sensor system exhibited a noise-equivalent field of 8 and a 3 dB bandwidth of ~10 MHz.

  18. Highly sensitive fiber-optic accelerometer by grating inscription in specific core dip fiber.

    Science.gov (United States)

    Rong, Qiangzhou; Guo, Tuan; Bao, Weijia; Shao, Zhihua; Peng, Gang-Ding; Qiao, Xueguang

    2017-09-19

    A highly sensitive fiber-optic accelerometer based on detecting the power output of resonances from the core dip is demonstrated. The sensing probe comprises a compact structure, hereby a short section of specific core (with a significant core dip) fiber stub containing a straight fiber Bragg grating is spliced to another single-mode fiber via a core self-alignment process. The femtosecond laser side-illumination technique was utilized to ensure that the grating inscription region is precisely positioned and compact in size. Two well-defined core resonances were achieved in reflection: one originates from the core dip and the other originates from fiber core. The key point is that only one of these two reflective resonances exhibits a high sensitivity to fiber bend (and vibration), whereas the other is immune to it. For low frequency (core mode reflection. Moreover, the sensor simultaneously provides an inherent power reference to eliminate unwanted power fluctuations from the light source and transmission lines, thus providing a means of evaluating weak seismic wave at low frequency.

  19. ORANGE: A high sensitivity particle tracker based on optically read out GEM

    Science.gov (United States)

    Marafini, M.; Patera, V.; Pinci, D.; Sarti, A.; Sciubba, A.; Spiriti, E.

    2017-02-01

    GEM-based detectors had a noticeable development in last years and have successfully been employed in different fields from High Energy Physics to imaging applications. Light production associated to the electron multiplication allows to perform an optical readout of these devices. The big progress achieved in CMOS-based photosensors makes possible to develop a high sensitivity, high granularity and low noise readout. In this paper we present the results obtained by reading out the light produced by a triple-GEM structure by means of a 4 mega-pixel CMOS sensor having a noise level less than two photons per pixel. The choice of a CF4 rich gas mixture (He/CF4 60/40) and a detailed optimisation of the electric fields allowed to reach a light-yield high enough to obtain very visible signals from minimum ionizing particles. In a test performed with 450 MeV electron beam, 800 photons per millimeter were collected and a space resolution of about 75 μ m was obtained.

  20. Temperature insensitive hysteresis free highly sensitive polymer optical fiber Bragg grating humidity sensor

    DEFF Research Database (Denmark)

    Woyessa, Getinet; Nielsen, Kristian; Stefani, Alessio

    2016-01-01

    sensitivity and a high hysteresis in the humidity response, in particular when operated at high temperature. PMMA mPOFBGs annealed at high humidity show higher and more linear humidity sensitivity with negligible hysteresis. We also report how annealing at high humidity can blue-shift the FBG wavelength more...

  1. SU-E-T-315: The Change of Optically Stimulated Luminescent Dosimeters (OSLDs) Sensitivity by Accumulated Dose and High Dose

    Energy Technology Data Exchange (ETDEWEB)

    Han, S; Jung, H; Kim, M; Ji, Y; Kim, K [University of Science and Technology, Daejeon (Korea, Republic of); Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Choi, S; Park, S; Yoo, H [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Yi, C [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2014-06-01

    Purpose: The objective of this study is to evaluate radiation sensitivity of optical stimulated luminance dosimeters (OSLDs) by accumulated dose and high dose. Methods: This study was carried out in Co-60 unit (Theratron 780, AECL, and Canada) and used InLight MicroStar reader (Landauer, Inc., Glenwood, IL) for reading. We annealed for 30 min using optical annealing system which contained fluorescent lamps (Osram lumilux, 24 W, 280 ∼780 nm). To evaluate change of OSLDs sensitivity by repeated irradiation, the dosimeters were repeatedly irradiated with 1 Gy. And whenever a repeated irradiation, we evaluated OSLDs sensitivity. To evaluate OSLDs sensitivity after accumulated dose with 5 Gy, We irradiated dose accumulatively (from 1 Gy to 5 Gy) without annealing. And OSLDs was also irradiated with 15, 20, 30 Gy to certify change of OSLDs sensitivity after high dose irradiation. After annealing them, they were irradiated with 1Gy, repeatedly. Results: The OSLDs sensitivity increased up to 3% during irradiating seven times and decreased continuously above 8 times. That dropped by about 0.35 Gy per an irradiation. Finally, after 30 times irradiation, OSLDs sensitivity decreased by about 7%. For accumulated dose from 1 Gy to 5 Gy, OSLDs sensitivity about 1 Gy increased until 4.4% after second times accumulated dose compared with before that. OSLDs sensitivity about 1 Gy decreased by 1.6% in five times irradiation. When OSLDs were irradiated ten times with 1Gy after irradiating high dose (10, 15, 20 Gy), OSLDs sensitivity decreased until 6%, 9%, 12% compared with it before high dose irradiation, respectively. Conclusion: This study certified OSLDs sensitivity by accumulated dose and high dose. When irradiated with 1Gy, repeatedly, OSLDs sensitivity decreased linearly and the reduction rate of OSLDs sensitivity after high dose irradiation had dependence on irradiated dose.

  2. Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique.

    Science.gov (United States)

    Khan, Md Rajibur Rahaman; Kang, Shin-Won

    2016-11-09

    In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal's pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The sensitivity of the proposed pH sensor is 0.46 µs/pH, and the correlation coefficient R² is approximately 0.997. Additional advantages of the proposed optical-fiber PWM pH sensor include a short/fast response-time of about 8 s, good reproducibility properties with a relative standard deviation (RSD) of about 0.019, easy fabrication, low cost, small size, reusability of the optical-fiber sensing-element, and the capability of remote sensing. Finally, the performance of the proposed PWM pH sensor was compared with that of potentiometric, optical-fiber modal interferometer, and optical-fiber Fabry-Perot interferometer pH sensors with respect to dynamic range width, linearity as well as response and recovery times. We observed that the proposed sensing systems have better sensing abilities than the above-mentioned pH sensors.

  3. Geometrical parameter analysis of the high sensitivity fiber optic angular displacement sensor

    CERN Document Server

    Sakamoto, João M S; Kitano, Cláudio; Tittmann, Bernhard R

    2015-01-01

    In this work, we present an analysis of the influence of the geometrical parameters on the sensitivity and linear range of the fiber optic angular displacement sensor, through computational simulations and experiments. The geometrical parameters analyzed were the lens focal length, the gap between fibers, the fibers cladding radii, the emitting fiber critical angle (or, equivalently, the emitting fiber numerical aperture), and the standoff distance (distance between the lens and the reflective surface). Besides, we analyzed the sensor sensitivity regarding any spurious linear displacement. The simulation and experimental results showed that the parameters which play the most important roles are the emitting fiber core radius, the lens focal length, and the light coupling efficiency, while the remaining parameters have little influence on sensor characteristics. This paper was published in Applied Optics and is made available as an electronic reprint with the permission of OSA. The paper can be found at the fo...

  4. Cavity-enhanced room-temperature high sensitivity optical Faraday magnetometry

    Science.gov (United States)

    Sun, Hui; Lei, Yaohua; Fan, Shuangli; Zhang, Qiaolin; Guo, Hong

    2017-01-01

    We propose a cavity QED system with two-photon Doppler-free configuration for weak magnetic field detection with high sensitivity at room temperature based on cavity electromagnetically induced transparency. Owing to the destructive interference induced by the control and driving fields, two transparency channels are opened. The Faraday rotation within two transparency channels can be used to detect weak magnetic field with high sensitivity at room temperature. The sensitivity with single photon and multiphoton probe inputs is analyzed. With single photon measurement, our numerical calculations demonstrate that the sensitivity with 3.8nT/√{Hz} and 6.4nT/√{Hz} could be achieved. When we measure the magnetic field with multiphoton input, the sensitivity can be improved to 7.7fT/√{Hz} and 25.6fT/√{Hz} under the realistic experimental conditions.

  5. High-Sensitivity Spectrophotometry.

    Science.gov (United States)

    Harris, T. D.

    1982-01-01

    Selected high-sensitivity spectrophotometric methods are examined, and comparisons are made of their relative strengths and weaknesses and the circumstances for which each can best be applied. Methods include long path cells, noise reduction, laser intracavity absorption, thermocouple calorimetry, photoacoustic methods, and thermo-optical methods.…

  6. Highly sensitive size discrimination of sub-micron objects using optical Fourier processing based on two-dimensional Gabor filters.

    Science.gov (United States)

    Pasternack, Robert M; Qian, Zhen; Zheng, Jing-Yi; Metaxas, Dimitris N; Boustany, Nada N

    2009-07-06

    We use optical Gabor-like filtering implemented with a digital micromirror device to achieve nanoscale sensitivity to changes in the size of finite and periodic objects imaged at low resolution. The method consists of applying an optical Fourier filter bank consisting of Gabor-like filters of varying periods and extracting the optimum filter period that maximizes the filtered object signal. Using this optimum filter period as a measure of object size, we show sensitivity to a 7.5 nm change in the period of a chirped phase mask with period around 1 microm. We also show 30 nm sensitivity to change in the size of polystyrene spheres with diameters around 500 nm. Unlike digital post-processing our optical processing method retains its sensitivity when implemented at low magnification in undersampled images. Furthermore, the optimum Gabor filter period found experimentally is linearly related to sphere diameter over the range 0.46 microm-1 microm and does not rely on a predictive scatter model such as Mie theory. The technique may have applications in high throughput optical analysis of subcellular morphology to study organelle function in living cells.

  7. Highly sensitive optical chemosensor for the detection of Cu2+ using a rhodamine B spirolatam

    Indian Academy of Sciences (India)

    Gen Hua Wu; Dong Xiang Wang; Da Yu Wu; Yuan Gao; Zhu Qing Wang

    2009-07-01

    Highly sensitive colorimetric chemosensor molecule RHN for selective detection of Cu2+ in mixed CH3CN aqueous media was designed and prepared by incorporating the well-known rhodamine fluorophore and a terdentate O2N binding unit into one molecule. The chemosensor RHN showed not only a reversible, selective, and sensitive absorbance enhancement response to Cu2+, but also a strong colour development against the colourless blank during the sensing event, a feature that would facilitate `naked-eye’ detection.

  8. Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique

    Directory of Open Access Journals (Sweden)

    Md. Rajibur Rahaman Khan

    2016-11-01

    Full Text Available In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM technique. According to the optical-fiber PWM method, the received sensing signal’s pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The sensitivity of the proposed pH sensor is 0.46 µs/pH, and the correlation coefficient R2 is approximately 0.997. Additional advantages of the proposed optical-fiber PWM pH sensor include a short/fast response-time of about 8 s, good reproducibility properties with a relative standard deviation (RSD of about 0.019, easy fabrication, low cost, small size, reusability of the optical-fiber sensing-element, and the capability of remote sensing. Finally, the performance of the proposed PWM pH sensor was compared with that of potentiometric, optical-fiber modal interferometer, and optical-fiber Fabry–Perot interferometer pH sensors with respect to dynamic range width, linearity as well as response and recovery times. We observed that the proposed sensing systems have better sensing abilities than the above-mentioned pH sensors.

  9. A High Sensitivity and Wide Dynamic Range Fiber-Optic Sensor for Low-Concentration VOC Gas Detection

    Directory of Open Access Journals (Sweden)

    Md. Rajibur Rahaman Khan

    2014-12-01

    Full Text Available In this paper, we propose a volatile organic compound (VOC gas sensing system with high sensitivity and a wide dynamic range that is based on the principle of the heterodyne frequency modulation method. According to this method, the time period of the sensing signal shift when Nile Red containing a VOC-sensitive membrane of a fiber-optic sensing element comes into contact with a VOC. This sensing membrane produces strong, fast and reversible signals when exposed to VOC gases. The response and recovery times of the proposed sensing system were less than 35 s, and good reproducibility and accuracy were obtained.

  10. A High Sensitivity and Wide Dynamic Range Fiber-Optic Sensor for Low-Concentration VOC Gas Detection

    Science.gov (United States)

    Khan, Md. Rajibur Rahaman; Kang, Shin-Won

    2014-01-01

    In this paper, we propose a volatile organic compound (VOC) gas sensing system with high sensitivity and a wide dynamic range that is based on the principle of the heterodyne frequency modulation method. According to this method, the time period of the sensing signal shift when Nile Red containing a VOC-sensitive membrane of a fiber-optic sensing element comes into contact with a VOC. This sensing membrane produces strong, fast and reversible signals when exposed to VOC gases. The response and recovery times of the proposed sensing system were less than 35 s, and good reproducibility and accuracy were obtained. PMID:25490592

  11. Natural motion of the optic nerve head revealed by high speed phase-sensitive OCT

    Science.gov (United States)

    OHara, Keith; Schmoll, Tilman; Vass, Clemens; Leitgeb, Rainer A.

    2013-03-01

    We use phase-sensitive optical coherence tomography (OCT) to measure the deformation of the optic nerve head during the pulse cycle, motivated by the possibility that these deformations might be indicative of the progression of glaucoma. A spectral-domain OCT system acquired 100k A-scans per second, with measurements from a pulse-oximeter recorded simultaneously, correlating OCT data to the subject's pulse. Data acquisition lasted for 2 seconds, to cover at least two pulse cycles. A frame-rate of 200-400 B-scans per second results in a sufficient degree of correlated speckle between successive frames that the phase-differences between fames can be extracted. Bulk motion of the entire eye changes the phase by several full cycles between frames, but this does not severely hinder extracting the smaller phase-changes due to differential motion within a frame. The central cup moves about 5 μm/s relative to the retinal-pigment-epithelium edge, with tissue adjacent to blood vessels showing larger motion.

  12. Highly sensitive force sensor based on optical microfiber asymmetrical Fabry-Perot interferometer.

    Science.gov (United States)

    Gong, Yuan; Yu, Cai-Bin; Wang, Ting-Ting; Liu, Xiu-Ping; Wu, Yu; Rao, Yun-Jiang; Zhang, Ming-Lei; Wu, Hui-Juan; Chen, Xiao-Xiao; Peng, Gang-Ding

    2014-02-10

    An asymmetrical Fabry-Perot interferometric (AFPI) force sensor is fabricated based on a narrowband reflection of low-reflectivity fiber Bragg grating (LR-FBG) and a broadband Fresnel reflection of the cleaved fiber end. The AFPI sensor includes a section of microfiber made by tapering and it achieves a force sensitivity of 0.221 pm/μN with a tapered microfiber of 40 mm length and 6.1 μm waist diameter. Compared with similar AFPI structure in 125 μm-diameter single mode fiber, the force sensitivity of the microfiber AFPI structure is greatly enhanced due to its smaller diameter and can be optimized for different force scales by controlling the diameter. The fabrication process of the AFPI sensor is simple and cost-effective. The AFPI sensor has better multiplexing capacity than conventional extrinsic fiber-optic Fabry-Perot sensors, while it also release the requirement on the wavelength matching of the FBG-pair-based FPI.

  13. Highly sensitive sensors based on magneto-optical surface plasmon resonance in Ag/CeYIG heterostructures

    Directory of Open Access Journals (Sweden)

    Jun Qin

    2015-01-01

    Full Text Available In this paper we present a new magneto-optical surface plasmon resonance (MOSPR sensor using a dielectric magneto-optical thin film of Ce1Y 2Fe5O12 (CeYIG and a metallic film of Ag. We demonstrate that by combining the low optical loss of Ag (ε =-62.485+4.331i and the strong magneto-optical effect of CeYIG (ΦF = 2 × 104 deg/cm at ∼1000 nm wavelength, a high figure of merit (FoM for index sensing can be achieved. The device shows a factor of 20 improvement in the index resolution in comparison with ferromagnetic metal based MOSPR sensors at the same wavelength. By carrying out both analytical and numerical simulations, an optimized Ag/CeYIG MOSPR structure with the highest index sensitivity is achieved at the incident light wavelength of 1160 nm and the CeYIG thickness of 25 nm. The enhanced resolution of the DMOSPR sensor has been attributed to both the field enhancement at the sensing interface due to the high index of CeYIG films and, the high magneto-optical figure of merit of the CeYIG near infrared wavelength range.

  14. High-sensitivity label-free optical fiber optrodes based on the excitation of Bloch surface waves

    Science.gov (United States)

    Scaravilli, M.; Castaldi, G.; Cusano, A.; Galdi, V.

    2016-05-01

    In this study, the possibility to excite Bloch surface waves (BSWs) on the tip of a single-mode optical fiber is explored for the first time. In particular, we first show the possibility to achieve an on-tip excitation of BSWs, with optimized characteristic of the arising resonances, via an "all-fiber" grating-coupled configuration. Furthermore, envisioning novel high-performance fiber tip nanoprobes for label-free biosensing, we introduce an ad hoc design aimed at maximizing the refractive-index sensitivity. Numerical results indicate that the estimated sensitivities are comparable with those exhibited by current plasmonic lab-on-tip bio-probes, but are accompanied by a higher spectral selectivity. Therefore, this preliminary work paves the way to the development of new classes of miniaturized surface-wave optical fiber devices for low-detection-limit label-free chemical and biological sensing.

  15. Highly sensitive optical biosensor based on silicon-microring-resonator-loaded Mach–Zehnder interferometer

    Science.gov (United States)

    Yoshida, Soichiro; Ishihara, Shintaro; Arakawa, Taro; Kokubun, Yasuo

    2017-04-01

    We propose and demonstrate a novel biosensor based on a silicon-single-microring-resonator-loaded Mach–Zehnder interferometer (MRR-MZI), and discuss the design of the sensor theoretically. Owing to the combination of an MZI and the enhanced phase change in a microring resonator (MRR), high sensitivity is expected to be realized. The designed MRR-MZI sensor is fabricated using a CMOS-compatible process, and its sensing characteristics are measured using ethanol solutions with a concentration of less than 3 wt % and avidin solutions. The sensitivity of the MRR-MZI to changes in the environmental refractive index is increased by approximately 50 times compared with that of a simple MRR. In addition, avidin solution with a concentration as low as 20 pM was successfully detected.

  16. Highly sensitive optical temperature sensor based on a SiN micro-ring resonator with liquid crystal cladding.

    Science.gov (United States)

    Wang, Chun-Ta; Wang, Cheng-Yu; Yu, Jui-Hao; Kuo, I-Tun; Tseng, Chih-Wei; Jau, Hung-Chang; Chen, Yung-Jui; Lin, Tsung-Hsien

    2016-01-25

    This work develops a sensitivity-enhanced optical temperature sensor that is based on a silicon nitride (SiN) micro-ring resonator that incorporates nematic liquid crystal (NLC) cladding. As the ambient temperature changes, the refractive index of the NLCs, which have a large thermal-optical coefficient, dramatically varies. The change in the refractive index of the NLC cladding that is caused by the temperature shift can alter the effective refractive index of the micro-ring resonator and make the resonance wavelength very sensitive to the ambient temperature. The temperature-sensitivity of the device with 5CB cladding for TM-polarized light was measured to be as high as 1nm/°C between 25 and 33 °C and over 2nm/°C at temperatures close to clearing temperature of the 5CB cladding. The temperature-sensitivity of the proposed device is at least 55 times that of the micro-ring resonator with air cladding, whose temperature-dependent wavelength shift for TM-polarized light is 18pm/ °C.

  17. A Highly Sensitive Fiber-Optic Fabry-Perot Interferometer Based on Internal Reflection Mirrors for Refractive Index Measurement.

    Science.gov (United States)

    Li, Xuefeng; Shao, Yujiao; Yu, Yuan; Zhang, Yin; Wei, Shaowen

    2016-05-31

    In this study, a new type of highly sensitive fiber-optic Fabry-Perot interferometer (FFPI) is proposed with a high sensitivity on a wide refractive index (RI) measurement range based on internal reflection mirrors of micro-cavity. The sensor head consists of a single-mode fiber (SMF) with an open micro-cavity. Since light reflections of gold thin films are not affected by the RI of different measuring mediums, the sensor is designed to improve the fringe visibility of optical interference through sputtering the gold films of various thicknesses on the inner surfaces of the micro-cavity, as a semi-transparent mirror (STM) and a total-reflection mirror (TRM). Experiments have been carried out to verify the feasibility of the sensor's design. It is shown that the fabricated sensor has strong interference visibility exceeding 15 dB over a wide measurement range of RI, and the sensor sensitivity is higher than 1160 nm/RIU, and RI resolution is better than 1.0 × 10(-6) RIU.

  18. High Sensitivity Refractometer Based on TiO2-Coated Adiabatic Tapered Optical Fiber via ALD Technology

    Science.gov (United States)

    Zhu, Shan; Pang, Fufei; Huang, Sujuan; Zou, Fang; Guo, Qiang; Wen, Jianxiang; Wang, Tingyun

    2016-01-01

    Atomic layer deposition (ALD) technology is introduced to fabricate a high sensitivity refractometer based on an adiabatic tapered optical fiber. Different thicknesses of titanium dioxide (TiO2) nanofilm were coated around the tapered fiber precisely and uniformly under different deposition cycles. Attributed to the higher refractive index of the TiO2 nanofilm compared to that of silica, an asymmetric Fabry–Perot (F-P) resonator could be constructed along the fiber taper. The central wavelength of the F-P resonator could be controlled by adjusting the thickness of the TiO2 nanofilm. Such a F-P resonator is sensitive to changes in the surrounding refractive index (SRI), which is utilized to realize a high sensitivity refractometer. The refractometer developed by depositing 50.9-nm-thickness TiO2 on the tapered fiber shows SRI sensitivity as high as 7096 nm/RIU in the SRI range of 1.3373–1.3500. Due to TiO2’s advantages of high refractive index, lack of toxicity, and good biocompatibility, this refractometer is expected to have wide applications in the biochemical sensing field. PMID:27537885

  19. Self-mixing laser Doppler vibrometry with high optical sensitivity application to real-time sound reproduction

    CERN Document Server

    Abe, K; Ko, J Y

    2003-01-01

    Nanometre vibration measurement of an audio speaker and a highly sensitive sound reproduction experiment have been successfully demonstrated by a self-aligned optical feedback vibrometry technique using the self-mixing modulation effect in a laser-diode-pumped microchip solid-state laser. By applying nanometre vibrations to the speaker, which produced nearly inaudible music below 20 dB (200 mu Pa) sound pressure level, we could reproduce clear sound in real time by the use of a simple frequency modulated wave demodulation circuit with a -120 dB light-intensity feedback ratio.

  20. High sensitive pulse oximeter-spectrophotometer for laser-optical dosimetry in biology and medicine

    Science.gov (United States)

    Asimov, M. M.; Asimov, R. M.; Rubinov, A. N.; Mamilov, S. A.; Plaksiy, Yu. S.

    2006-03-01

    High sensitive multi channel pulse oxymeter - spectrophotometer for control of the local tissue oxygen saturation is presented. Due to an original method of data storing and processing the accuracy of measurements 3-4 times are increased in compare with similar systems. This system is used for registration of the local changes of arterial blood saturation with oxygen under effect of low intensity laser radiation. It is shown that the photodissociation of oxyhemoglobin in cutaneous blood vessels play a dominant role in the mechanism of biostimulating and therapeutic effect of low intensity laser radiation. The results of experimental investigation in vivo the dependence of arterial oxygen blood saturation on temperature and the wavelength of laser radiation are presented. It is suggested that dosimetry for laser therapy could be base on regulation of local concentration of free oxygen in tissue.

  1. Highly selective and sensitive determination of copper ion by two novel optical sensors

    Directory of Open Access Journals (Sweden)

    Mehrorang Ghaedi

    2017-05-01

    Full Text Available New optical sensors for the determination of copper ion by incorporation of 1,1′-(4-nitro-1,2-phenylenebis(azan-1-yl-1-ylidenebis(methan-1-yl-1-lidenedinaphthalen-2-ol(L1, 1,1′-2,2′-(1,2-phenylenebis(ethene-2,1-diyldinaphthalen-2-ol 1(L2, dibutylphthalate (DBP and sodium tetraphenylborate (Na-TPB to the plasticized polyvinyl chloride matrices were prepared. The tendency of both ionophores (L2 and L1 as chromoionophore was significantly enhanced by the addition of DBP to the membrane. The proposed sensors benefit from advantages such as high stability, reproducibility and relatively long lifetime, good selectivity for Cu2+ ion determination over a large number of alkali, alkaline earth, transition and heavy metal ions. At optimum values of membrane compositions and experimental conditions, both sensors’ response was linear over a concentration range of 7.98 × 10−6 to 1.31 × 10−4mol L−1 and 1.99 × 10−6 to 5.12 × 10−5 mol L−1 for L2 and L1, respectively. Sensor detection limit based on the definition that the concentration of the sample leads to a signal equal to the blank signal plus three times of its standard deviation was found to be 3.99 × 10−7 and 5.88 × 10−7 mol L−1 for L2 and L1, respectively. The response time of the optodes (defined as the time required reaching the 90% of the peak signal was found to be 5–8 min for L2 and 20–25 min for L1 based sensor. The proposed optical sensors were applied successfully for the determination of Cu2+ ion content in water samples.

  2. High-sensitivity operation of single-beam optically pumped magnetometer in a kHz frequency range

    Science.gov (United States)

    Savukov, I.; Kim, Y. J.; Shah, V.; Boshier, M. G.

    2017-03-01

    Optically pumped magnetometers (OPM) can be used in various applications, from magnetoencephalography to magnetic resonance imaging and nuclear quadrupole resonance (NQR). OPMs provide high sensitivity and have the significant advantage of non-cryogenic operation. To date, many magnetometers have been demonstrated with sensitivity close to 1 fT, but most devices are not commercialized. Most recently, QuSpin developed a model of OPM that is low cost, high sensitivity, and convenient for users, which operates in a single-beam configuration. Here we developed a theory of single-beam (or parallel two-beam) magnetometers and showed that it is possible to achieve good sensitivity beyond their usual frequency range by tuning the magnetic field. Experimentally we have tested and optimized a QuSpin OPM for operation in the frequency range from DC to 1.7 kHz, and found that the performance was only slightly inferior despite the expected decrease due to deviation from the spin-exchange relaxation-free regime.

  3. Highly Sensitive Photon Counting Detectors for Deep Space Optical Communications Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A new type of a photon-counting photodetector is proposed to advance the state-of the-art in deep space optical communications technology. The proposed detector...

  4. High-sensitivity optical Faraday magnetometry with intracavity electromagnetically induced transparency

    Science.gov (United States)

    Zhang, Qiaolin; Sun, Hui; Fan, Shuangli; Guo, Hong

    2016-12-01

    We suggest a multiatom cavity quantum electrodynamics system for the detection of a weak magnetic field, based on Faraday rotation with intracavity electromagnetically induced transparency. Our study demonstrates that the collective coupling between the cavity modes and the atomic ensemble can be used to improve the sensitivity. With single-probe photon input, the sensitivity is inversely proportional to the number of atoms, and a sensitivity of 2.45 nT Hz-1/2 could be attained. With multiphoton measurement, our numerical calculations show that the magnetic field sensitivity can be improved to 105.6 aT Hz-1/2 with realistic experimental conditions.

  5. Design of a porous cored hexagonal photonic crystal fiber based optical sensor with high relative sensitivity for lower operating wavelength

    Science.gov (United States)

    Sen, Shuvo; Chowdhury, Sawrab; Ahmed, Kawsar; Asaduzzaman, Sayed

    2017-03-01

    In this article, highly sensitive and low confinement loss enriching micro structured photonic crystal fiber (PCF) has been suggested as an optical sensor. The proposed PCF is porous cored hexagonal (P-HPCF) where cladding contains five layers with circular air holes and core vicinity is formed by two layered elliptical air holes. Two fundamental propagation characteristics such as the relative sensitivity and confinement loss of the proposed P-HPCF have been numerically scrutinized by the full vectorial finite element method (FEM) simulation procedure. The optimized values are modified with different geometrical parameters like diameters of circular or elliptical air holes, pitches of the core, and cladding region over a spacious assortment of wavelength from 0.8 µm to 1.8 µm. All pretending results exhibit that the relative sensitivity is enlarged according to decrement of wavelength of the transmission band (O+E+S+C+L+U). In addition, all useable liquids reveal the maximum sensitivity of 57.00%, 57.18%, and 57.27% for n=1.33, 1.354, and 1.366 respectively by lower band. Moreover, effective area, nonlinear coefficient, frequency, propagation constant, total electric energy, total magnetic energy, and wave number in free space of the proposed P-HPCF have been reported recently.

  6. A high sensitivity optically stimulated luminescence scanning system for measurement of single sand-sized grains

    DEFF Research Database (Denmark)

    Duller, G.A.T.; Bøtter-Jensen, L.; Kohsiek, P.;

    1999-01-01

    An instrument has been designed for the routine analysis of the optically stimulated luminescence signal from single grains of sand. The system is capable of analysing over 3000 individual grains in a single measurement sequence, and the OSL signal from each grain can be read in less than 3 s....... The design principles are described, along with preliminary measurements that illustrate the operation of the system and its capabilities....

  7. Automatically tunable continuous-wave optical parametric oscillator for high-resolution spectroscopy and sensitive trace-gas detection

    Science.gov (United States)

    Ngai, A. K. Y.; Persijn, S. T.; von Basum, G.; Harren, F. J. M.

    2006-11-01

    We present a high-power (2.75 W), broadly tunable (2.75-3.83 μm) continuous-wave optical parametric oscillator based on MgO-doped periodically poled lithium niobate. Automated tuning of the pump laser, etalon and crystal temperature results in a continuous wavelength coverage up to 450 cm-1 per poling period at water in human breath were measured using photoacoustics. Methane (at 3.2 μm) and ethane (at 3.3 μm) were detected using cavity ring-down spectroscopy with detection limits of 0.16 and 0.07 parts per billion by volume, respectively. A recording of 12CH4 and 13CH4 isotopes of methane shows the ability to detect both species simultaneously at similar sensitivities.

  8. Phase-sensitive optical coherence tomography-based vibrometry using a highly phase-stable akinetic swept laser source

    Energy Technology Data Exchange (ETDEWEB)

    Applegate, Brian E.; Park, Jesung; Carbajal, Esteban [Department of Biomedical Engineering, Texas A& M University, College Station, Texas (United States); Oghalai, John S. [Department of Otolaryngology - Head and Neck Surgery, Stanford University, Stanford, California (United States)

    2015-12-31

    Phase-sensitive Optical Coherence Tomography (PhOCT) is an emerging tool for in vivo investigation of the vibratory function of the intact middle and inner ear. PhOCT is able to resolve micron scale tissue morphology in three dimensions as well as measure picometer scale motion at each spatial position. Most PhOCT systems to date have relied upon the phase stability offered by spectrometer detection. On the other hand swept laser source based PhOCT offers a number of advantages including balanced detection, long imaging depths, and high imaging speeds. Unfortunately the inherent phase instability of traditional swept laser sources has necessitated complex user developed hardware/software solutions to restore phase sensitivity. Here we present recent results using a prototype swept laser that overcomes these issues. The akinetic swept laser is electronically tuned and precisely controls sweeps without any mechanical movement, which results in high phase stability. We have developed an optical fiber based PhOCT system around the akinetic laser source that had a 1550 nm center wavelength and a sweep rate of 140 kHz. The stability of the system was measured to be 4.4 pm with a calibrated reflector, thus demonstrating near shot noise limited performance. Using this PhOCT system, we have acquired structural and vibratory measurements of the middle ear in a mouse model, post mortem. The quality of the results suggest that the akinetic laser source is a superior laser source for PhOCT with many advantages that greatly reduces the required complexity of the imaging system.

  9. Highly Sensitive Temperature Sensors Based on Fiber-Optic PWM and Capacitance Variation Using Thermochromic Sensing Membrane.

    Science.gov (United States)

    Khan, Md Rajibur Rahaman; Kang, Shin-Won

    2016-07-09

    In this paper, we propose a temperature/thermal sensor that contains a Rhodamine-B sensing membrane. We applied two different sensing methods, namely, fiber-optic pulse width modulation (PWM) and an interdigitated capacitor (IDC)-based temperature sensor to measure the temperature from 5 °C to 100 °C. To the best of our knowledge, the fiber-optic PWM-based temperature sensor is reported for the first time in this study. The proposed fiber-optic PWM temperature sensor has good sensing ability; its sensitivity is ~3.733 mV/°C. The designed temperature-sensing system offers stable sensing responses over a wide dynamic range, good reproducibility properties with a relative standard deviation (RSD) of ~0.021, and the capacity for a linear sensing response with a correlation coefficient of R² ≈ 0.992 over a wide sensing range. In our study, we also developed an IDC temperature sensor that is based on the capacitance variation principle as the IDC sensing element is heated. We compared the performance of the proposed temperature-sensing systems with different fiber-optic temperature sensors (which are based on the fiber-optic wavelength shift method, the long grating fiber-optic Sagnac loop, and probe type fiber-optics) in terms of sensitivity, dynamic range, and linearity. We observed that the proposed sensing systems have better sensing performance than the above-mentioned sensing system.

  10. Ultra-high-sensitive optical micro-angiography provides depth resolved visualization of microcirculations within human skin under psoriatic conditions

    Science.gov (United States)

    Qin, Jia; An, Lin; Wang, Ruikang

    2011-03-01

    Adequate functioning of the peripheral micro vascular in human skin is necessary to maintain optimal tissue perfusion and preserve normal hemodynamic function. There is a growing body of evidence suggests that vascular abnormalities may directly related to several dermatologic diseases, such as psoriasis, port-wine stain, skin cancer, etc. New in vivo imaging modalities to aid volumetric microvascular blood perfusion imaging are there for highly desirable. To address this need, we demonstrate the capability of ultra-high sensitive optical micro angiography to allow blood flow visualization and quantification of vascular densities of lesional psoriasis area in human subject in vivo. The microcirculation networks of lesion and non-lesion skin were obtained after post processing the data sets captured by the system. With our image resolution (~20 μm), we could compare these two types of microcirculation networks both qualitatively and quantitatively. The B-scan (lateral or x direction) cross section images, en-face (x-y plane) images and the volumetric in vivo perfusion map of lesion and non-lesion skin areas were obtained using UHS-OMAG. Characteristic perfusion map features were identified between lesional and non-lesional skin area. A statistically significant difference between vascular densities of lesion and non-lesion skin area was also found using a histogram based analysis. UHS-OMAG has the potential to differentiate the normal skin microcirculation from abnormal human skin microcirculation non-invasively with high speed and sensitivity. The presented data demonstrates the great potential of UHS-OMAG for detecting and diagnosing skin disease such as psoriasis in human subjects.

  11. High sensitivity of diesel soot morphological and optical properties to combustion temperature in a shock tube.

    Science.gov (United States)

    Qiu, Chong; Khalizov, Alexei F; Hogan, Brian; Petersen, Eric L; Zhang, Renyi

    2014-06-03

    Carbonaceous particles produced from combustion of fossil fuels have strong impacts on air quality and climate, yet quantitative relationships between particle characteristics and combustion conditions remain inadequately understood. We have used a shock tube to study the formation and properties of diesel combustion soot, including particle size distributions, effective density, elemental carbon (EC) mass fraction, mass-mobility scaling exponent, hygroscopicity, and light absorption and scattering. These properties are found to be strongly dependent on the combustion temperature and fuel equivalence ratio. Whereas combustion at higher temperatures (∼2000 K) yields fractal particles of a larger size and high EC content (90 wt %), at lower temperatures (∼1400 K) smaller particles of a higher organic content (up to 65 wt %) are produced. Single scattering albedo of soot particles depends largely on their organic content, increasing drastically from 0.3 to 0.8 when the particle EC mass fraction decreases from 0.9 to 0.3. The mass absorption cross-section of diesel soot increases with combustion temperature, being the highest for particles with a higher EC content. Our results reveal that combustion conditions, especially the temperature, may have significant impacts on the direct and indirect climate forcing of atmospheric soot aerosols.

  12. Noise-immune cavity-enhanced optical frequency comb spectroscopy: A sensitive technique for high-resolution broadband molecular detection

    CERN Document Server

    Khodabakhsh, Amir; Foltynowicz, Aleksandra

    2014-01-01

    Noise-immune cavity-enhanced optical frequency comb spectroscopy (NICE-OFCS) is a recently developed technique that utilizes phase modulation to obtain immunity to frequency-to-amplitude noise conversion by the cavity modes and yields high absorption sensitivity over a broad spectral range. We describe the principles of the technique and discuss possible comb-cavity matching solutions. We present a theoretical description of NICE-OFCS signals detected with a Fourier transform spectrometer (FTS), and validate the model by comparing it to experimental CO2 spectra around 1575 nm. Our system is based on an Er:fiber femtosecond laser locked to a cavity and phase-modulated at a frequency equal to a multiple of the cavity free spectral range (FSR). The NICE-OFCS signal is detected by a fast-scanning FTS equipped with a high-bandwidth commercial detector. We demonstrate a simple method of passive locking of the modulation frequency to the cavity FSR that significantly improves the long term stability of the system, a...

  13. Sensitive fiber-optic immunoassay

    Science.gov (United States)

    Walczak, Irene M.; Love, Walter F.; Slovacek, Rudolf E.

    1991-07-01

    The principles of evanescent wave theory were applied to an immunological sensor for detecting the cardiac-specific isoenzyme creatine kinase-MB (CK-MB). The detection of the CK-MB isoenzyme is used in conjunction with the total CK measurement in the diagnosis of acute myocardial infarction. The clinical range for CK-MB is from 2-100 ng/ml. Previous work which utilized the fluorophor, Fluorescein isothiocyanate (FITC), was able to discriminate between 0 and 3 ng/ml CK-MB. Use of the fluorophor B-phycoerythrin (BPE) increased the assay sensitivity to 0.1 ng/ml CK-MB. The data was collected for 15 minutes using an optical launch and collection angle of 25 degree(s). This fiber optic based system is homogeneous and requires no subsequent washing, handling, or processing steps after exposure to the sample.

  14. Fiber-optic Michelson interferometer with high sensitivity based on a liquid-filled photonic crystal fiber

    Science.gov (United States)

    Hsu, Jui-Ming; Horng, Jing-Shyang; Hsu, Chia-Ling; Lee, Cheng-Ling

    2014-11-01

    This study proposes an ultracompact and highly sensitive liquid-filled photonic crystal fiber Michelson interferometer (LF-PCFMI) based on material dispersion engineering. Numerical simulations and experimental measurements are performed in the work, and both of their results show that the temperature sensitivity can be more greatly improved than those of conventional photonic crystal fiber interferometers (PCFIs). The experimental results indicate that a very high sensitivity with interference wavelength shifts of almost 27 nm within temperature variation of 5 °C has been achieved by the configuration. Numerical analysis for the proposed LF-PCFMI also exhibits a good agreement with the results of the experimental measurements.

  15. Highly sensitive and simple method for refractive index sensing of liquids in microstructured optical fibers using four-wave mixing

    DEFF Research Database (Denmark)

    Frosz, Michael Henoch; Stefani, Alessio; Bang, Ole

    2011-01-01

    We present both experimental measurements and simulations for a simple fiber-optical liquid refractive index sensor, made using only commercially available components and without advanced postprocessing of the fiber. Despite the simplicity, we obtain the highest sensitivity experimentally...... demonstrated to date for aqueous solutions (refractive index around 1.33), which is relevant for extensions to biosensing. The sensor is based on measuring the spectral shift of peaks arising from four-wave mixing (FWM), when filling the holes of a microstructured fiber with different liquid samples...

  16. Reflective type objective based spectral-domain phase-sensitive optical coherence tomography for high-sensitive structural and functional imaging of cochlear microstructures through intact bone of an excised guinea pig cochlea

    Science.gov (United States)

    Subhash, Hrebesh M.; Wang, Ruikang K.; Chen, Fangyi; Nuttall, Alfred L.

    2013-03-01

    Most of the optical coherence tomographic (OCT) systems for high resolution imaging of biological specimens are based on refractive type microscope objectives, which are optimized for specific wave length of the optical source. In this study, we present the feasibility of using commercially available reflective type objective for high sensitive and high resolution structural and functional imaging of cochlear microstructures of an excised guinea pig through intact temporal bone. Unlike conventional refractive type microscopic objective, reflective objective are free from chromatic aberrations due to their all-reflecting nature and can support a broadband of spectrum with very high light collection efficiency.

  17. Construction of optical glucose nanobiosensor with high sensitivity and selectivity at physiological pH on the basis of organic-inorganic hybrid microgels.

    Science.gov (United States)

    Wu, Weitai; Zhou, Ting; Aiello, Michael; Zhou, Shuiqin

    2010-08-15

    A new class of optical glucose nanobiosensors with high sensitivity and selectivity at physiological pH is described. To construct these glucose nanobiosensors, the fluorescent CdS quantum dots (QDs), serving as the optical code, were incorporated into the glucose-sensitive poly(N-isopropylacrylamide-acrylamide-2-acrylamidomethyl-5-fluorophenylboronic acid) copolymer microgels, via both in situ growth method and "breathing in" method, respectively. The polymeric gel can adapt to surrounding glucose concentrations, and regulate the fluorescence of the embedded QDs, converting biochemical signals into optical signals. The gradual swelling of the gel would lead to the quenching of the fluorescence at the elevated glucose concentrations. The hybrid microgels displayed high selectivity to glucose over the potential primary interferents of lactate and human serum albumin in the physiologically important glucose concentration range. The stability, reversibility, and sensitivity of the organic-inorganic hybrid microgel-based biosensors were also systematically studied. These general properties of our nanobiosensors are well tunable under appropriate tailor on the hybrid microgels, in particular, simply through the change in the crosslinking degree of the microgels. The optical glucose nanobiosensors based on the organic-inorganic hybrid microgels have shown the potential for a third generation fluorescent biosensor.

  18. QPSK-to-2×BPSK wavelength and modulation format conversion through phase-sensitive four-wave mixing in a highly nonlinear optical fiber

    DEFF Research Database (Denmark)

    Da Ros, Francesco; Dalgaard, Kjeld; Lei, Lei

    2013-01-01

    A phase-sensitive four-wave mixing (FWM) scheme enabling the simultaneous conversion of the two orthogonal quadratures of an optical signal to different wavelengths is demonstrated for the first time under dynamic operation using a highly nonlinear optical fiber (HNLF) as the nonlinear medium....... The scheme is first optimized with respect to the power levels and phases of the four phase-coherent pumps. The successful modulation and wavelength conversion of the two complex quadratures of a quadrature phase-shift keying (QPSK) signal to two binary phase-shift keying (BPSK) signals is then demonstrated...

  19. Folded cladding porous shaped photonic crystal fiber with high sensitivity in optical sensing applications: Design and analysis

    Directory of Open Access Journals (Sweden)

    Bikash Kumar Paul

    2017-02-01

    Full Text Available A micro structure folded cladding porous shaped with circular air hole photonic crystal fiber (FP-PCF is proposed and numerically investigated in a broader wavelength range from 1.4 µm to 1.64 µm (E+S+C+L+U for chemical sensing purposes. Employing finite element method (FEM with anisotropic perfectly matched layer (PML various properties of the proposed FP-PCF are numerically inquired. Filling the hole of core with aqueous analyte ethanol (n = 1.354 and tuning different geometric parameters of the fiber, the sensitivity order of 64.19% and the confinement loss of 2.07 × 10-5 dB/m are attained at 1.48 µm wavelength in S band. The investigated numerical simulation result strongly focuses on sensing purposes; because this fiber attained higher sensitivity with lower confinement loss over the operating wavelength. Measuring time of sensitivity, simultaneously confinement loss also inquired. It reflects that confinement loss is highly dependable on PML depth but not for sensitivity. Beside above properties numerical aperture (NA, nonlinearity, and effective area are also computed. This FP-PCF also performed as sensor for other alcohol series (methanol, propanol, butanol, pentanol. Optimized FP-PCF shows higher sensitivity and low confinement loss carrying high impact in the area of chemical as well as gas sensing purposes. Surely it is clear that install such type of sensor will flourish technology massively.

  20. A high-sensitivity fiber-optic evanescent wave sensor with a three-layer structure composed of Canada balsam doped with GeO2.

    Science.gov (United States)

    Zhong, Nianbing; Zhao, Mingfu; Zhong, Lianchao; Liao, Qiang; Zhu, Xun; Luo, Binbin; Li, Yishan

    2016-11-15

    In this paper, we present a high-sensitivity polymer fiber-optic evanescent wave (FOEW) sensor with a three-layer structure that includes bottom, inter-, and surface layers in the sensing region. The bottom layer and inter-layer are POFs composed of standard cladding and the core of the plastic optical fiber, and the surface layer is made of dilute Canada balsam in xylene doped with GeO2. We examine the morphology of the doped GeO2, the refractive index and composition of the surface layer and the surface luminous properties of the sensing region. We investigate the effects of the content and morphology of the GeO2 particles on the sensitivity of the FOEW sensors by using glucose solutions. In addition, we examine the response of sensors incubated with staphylococcal protein A plus mouse IgG isotype to goat anti-mouse IgG solutions. Results indicate very good sensitivity of the three-layer FOEW sensor, which showed a 3.91-fold improvement in the detection of the target antibody relative to a conventional sensor with a core-cladding structure, and the novel sensor showed a lower limit of detection of 0.2ng/l and a response time around 320s. The application of this high-sensitivity FOEW sensor can be extended to biodefense, disease diagnosis, biomedical and biochemical analysis.

  1. Cascaded fiber-optic Fabry-Perot interferometers with Vernier effect for highly sensitive measurement of axial strain and magnetic field.

    Science.gov (United States)

    Zhang, Peng; Tang, Ming; Gao, Feng; Zhu, Benpeng; Fu, Songnian; Ouyang, Jun; Shum, Perry Ping; Liu, Deming

    2014-08-11

    We report a highly sensitive fiber-optic sensor based on two cascaded intrinsic fiber Fabry-Perot interferometers (IFFPIs). The cascaded IFFPIs have different free spectral ranges (FSRs) and are formed by a short section of hollow core photonic crystal fiber sandwiched by two single mode fibers. With the superposition of reflective spectrum with different FSRs, the Vernier effect will be generated in the proposed sensor and we found that the strain sensitivity of the proposed sensor can be improved from 1.6 pm/με for a single IFFPI sensor to 47.14 pm/με by employing the Vernier effect. The sensor embed with a metglas ribbon can be also used to measure the magnetic field according to the similar principle. The sensitivity of the magnetic field measurement is achieved to be 71.57 pm/Oe that is significantly larger than the 2.5 pm/Oe for a single IFFPI sensor.

  2. A high-sensitivity chemical sensor based on titania coated optical-fiber long period grating for ammonia sensing in water

    Science.gov (United States)

    Tiwari, D.; James, S. W.; Tatam, R. P.; Korposh, S.; Lee, S. W.

    2015-07-01

    Two highly sensitive ammonia sensors, formed by depositing coatings composed of titanium dioxide (TiO2) onto the cladding of an optical fibre sensing platform, are evaluated. A long period grating (LPG) of period 111 μm was fabricated in the core of an optical fibre so that the LPG operates at or near the phase matching turning point (PMTP). The first coating that was investigated was composed of TiO2 nanoparticles deposited by liquid phase deposition. The sensor showed high sensitivity and allowed low concentrations of ammonia in water (0.01 ppm) to be detected with a response time of less than 60 sec. The second coating was composed of TiO2 with subsequent layers of poly (allyamine hydrochloride) (PAH), and SiO2 nanospheres infused with a sensitive element composed of porphine. The ammonia adsorption to the porphine compound led to the changes in the LPG's transmission spectrum and allowed 0.1 ppm of ammonia in water to be detected with a response time of less than 60 sec.

  3. Optical cavity coupled surface plasmon resonance sensing for enhanced sensitivity

    Institute of Scientific and Technical Information of China (English)

    Zheng Zheng; Xin Zhao; Jinsong Zhu; Jim Diamond

    2008-01-01

    A surface plasmon resonance (SPR) sensing system based on the optical cavity enhanced detection tech-nique is experimentally demonstrated. A fiber-optic laser cavity is built with a SPR sensor inside. By measuring the laser output power when the cavity is biased near the threshold point, the sensitivity, defined as the dependence of the output optical intensity on the sample variations, can be increased by about one order of magnitude compared to that of the SPR sensor alone under the intensity interrogation scheme. This could facilitate ultra-high sensitivity SPR biosensing applications. Further system miniaturization is possible by using integrated optical components and waveguide SPR sensors.

  4. Highly selective and sensitive optical sensor for determination of Pb2+and Hg2+ ions based on the covalent immobilization of dithizone on agarose membrane

    Science.gov (United States)

    Zargoosh, Kiomars; Babadi, Fatemeh Farhadian

    2015-02-01

    A highly sensitive and selective optical membrane for determination of Hg2+ and Pb2+ was prepared by covalent immobilization of dithizone on agarose membrane. In addition to its high stability, reproducibility and relatively long lifetime, the proposed optical sensor revealed good selectivity for target ions over a large number of alkali, alkaline earth, transition, and heavy metal ions. The proposed optical membrane displays linear responses from 1.1 × 10-8 to 2.0 × 10-6 mol L-1 and 1.2 × 10-8 to 2.4 × 10-6 mol L-1 for Hg2+ and Pb2+, respectively. The limits of detection (LOD) were 2.0 × 10-9 mol L-1 and 4.0 × 10-9 mol L-1 for Hg2+ and Pb2, respectively. The prepared optical membrane was successfully applied to the determination of Hg2+ and Pb2+ in industrial wastes, spiked tap water and natural waters without any preconcentration step.

  5. A novel luciferase fusion protein for highly sensitive optical imaging: from single-cell analysis to in vivo whole-body bioluminescence imaging.

    Science.gov (United States)

    Mezzanotte, Laura; Blankevoort, Vicky; Löwik, Clemens W G M; Kaijzel, Eric L

    2014-09-01

    Fluorescence and bioluminescence imaging have different advantages and disadvantages depending on the application. Bioluminescence imaging is now the most sensitive optical technique for tracking cells, promoter activity studies, or for longitudinal in vivo preclinical studies. Far-red and near-infrared fluorescence imaging have the advantage of being suitable for both ex vivo and in vivo analysis and have translational potential, thanks to the availability of very sensitive imaging instrumentation. Here, we report the development and validation of a new luciferase fusion reporter generated by the fusion of the firefly luciferase Luc2 to the far-red fluorescent protein TurboFP635 by a 14-amino acid linker peptide. Expression of the fusion protein, named TurboLuc, was analyzed in human embryonic kidney cells, (HEK)-293 cells, via Western blot analysis, fluorescence microscopy, and in vivo optical imaging. The created fusion protein maintained the characteristics of the original bioluminescent and fluorescent protein and showed no toxicity when expressed in living cells. To assess the sensitivity of the reporter for in vivo imaging, transfected cells were subcutaneously injected in animals. Detection limits of cells were 5 × 10(3) and 5 × 10(4) cells for bioluminescent and fluorescent imaging, respectively. In addition, hydrodynamics-based in vivo gene delivery using a minicircle vector expressing TurboLuc allowed for the analysis of luminescent signals over time in deep tissue. Bioluminescence could be monitored for over 30 days in the liver of animals. In conclusion, TurboLuc combines the advantages of both bioluminescence and fluorescence and allows for highly sensitive optical imaging ranging from single-cell analysis to in vivo whole-body bioluminescence imaging.

  6. Ultra-high resolution polarization-sensitive optical coherence microscopy for brain imaging at 6 um, 3.4 um and 1.3 um resolution (Conference Presentation)

    Science.gov (United States)

    Wang, Hui; Akkin, Taner; Magnain, Caroline V.; Yaseen, Mohammad A.; Cramer, Avilash; Wang, Ruopeng; Sakadžic, Sava; Boas, David A.

    2016-03-01

    Neuroanatomical pathways form the basis for functional activity of brain circuits. In the past, we developed a polarization-sensitive optical coherence tomography with serial scanning to achieve large-scale brain imaging. The system was able to visualize 3D fiber tracts of ~20 um in diameter. To investigate the neuroanatomical pathways at finer scales, we have now built a polarization-maintaining fiber based ultra-high resolution polarization-sensitive optical coherence microscope (PS-OCM) at 1300 nm. The PS-OCM has an axial resolution of 3.5 um in tissue. The detection setup consists of two spectrometers, acquiring spectral interference on orthogonal polarization channels. With a single measurement, the setup generates four contrasts: reflectivity, cross-polarization, retardance and optic axis orientation. To investigate the capability of PS-OCM at different resolutions, we used three microscope objectives that yield lateral resolutions of 6.0 um, 3.4 um and 1.3 um. Blocks of formalin fixed mouse brain and human brain were scanned. The cross-polarization and retardance images clearly depict the neuronal fiber structures, which are comparable with that generated by the maximum projection of volumetric reflectivity data. The optic axis orientation quantifies the in-plane fiber orientation. With the lateral resolution of 1.3 um, the retardance contrast is weak in white matter due to the shallow depth of focus. Overall, the ultra-high resolution PS-OCM provides a new tool to reveal neuroanatomical maps in the brain at cellular resolution.

  7. Optical Design of Dye-Sensitized Nanocrystalline Solar Cells

    Institute of Scientific and Technical Information of China (English)

    LIU Xi-Zhe; MENG Qing-Bo; GAO Chun-Xiao; XUE Bo-Fei; WANG Hong-Xia; CHEN Li-Quan; O.Sato; A.Fujishima

    2004-01-01

    In nanocrystalline dye-sensitized solar cells (DSSCs) the absorption of a large fraction of the incident solar radiation is important for achieving high efficiencies. We develop a model to include both the optical process and the electrochemical process. This model allows us to calculate the performance of the different optical designs (for example the different scattering layers and the different reflecting plane). It is found that appropriate optical designs can improve the performance of DSSCs greatly.

  8. Highly sensitive size discrimination of sub-micron objects using optical Fourier processing based on two-dimensional Gabor filters

    National Research Council Canada - National Science Library

    Robert M. Pasternack; Zhen Qian; Jing-Yi Zheng; Dimitris N. Metaxas; Nada N. Boustany

    2009-01-01

    .... The method consists of applying an optical Fourier filter bank consisting of Gabor-like filters of varying periods and extracting the optimum filter period that maximizes the filtered object signal...

  9. Ultra-high sensitivity optical biosensor based on Vernier effect in triangular ring resonators (TRRs) with SPR

    Science.gov (United States)

    Kim, Tae-Ryong; Kim, Hong-Seung; Li, Jun; Oh, Geum-Yoon; Kim, Doo-Gun; Choi, Young-Wan

    2015-03-01

    In this paper, surface plasmon resonance triangular ring resonator (SPR-TRR) Vernier structure based on InP is simulated for index variation from 1.33 to 1.35. Sensing area of SPR-TRR is achieved to make an ultra-compact SPR mirror by deposition of Au film layer which is designed to deposit on vertex of TRR. The possibility of mass production is shown by a deposition of SPR mirror on the triangular ring resonator (TRR). Also, the sensitivity enhancement of an envelope signal for Vernier effect is confirmed by FDTD simulation compared to SPR-TRR. As simulation results, the sensitivity is enhanced 20 nm / RIU to 480 nm / RIU. Thus, SPR-TRR Vernier structure is used for a biosensor to enhance the sensitivity of biosensor.

  10. Study of optical sensors of the form Al/a-SiC:H/c-Si(n with high sensitivity.

    Directory of Open Access Journals (Sweden)

    L. Magafas

    2008-06-01

    Full Text Available In the present work optical sensors of the form Al/a-SiC:H/c-Si(n, for different thickness of a-SiC:H thin films are stud-ied. More specifically, a-SiC:H thin films were deposited by rf sputtering technique on c-Si(n substrates for different thickness of the amorphous semiconductor and, subsequently, the samples were annealed in the temperature range from 300oC up to 675 oC. Experimental measurements of the optical response of these sensors showed that for thicknesses of a-SiC:H greater than a critical value, which depends on annealing temperature, a mechanism of losses is appeared in the region of wavelengths from 525nm up to 625nm. This behaviour is attributed to the recombination of photo-generated electrons-hole pairs in the neutral region of a-SiC:H, when this exceeds the diffusion length of minority carries, Lp. Also, the value of the reverse bias voltage appears to influence considerably the optical response of these sensors when d > Lp in the case where the a-SiC: H thin films were annealed at 600oC.

  11. Sensitivity enhancement in evanescent optical waveguidesensors

    NARCIS (Netherlands)

    Veldhuis, G.J.; Parriaux, O.; Hoekstra, Hugo; Lambeck, Paul

    2000-01-01

    It is shown, that the sensitivity of the effective refractive index on the cladding index in evanescent optical waveguide sensors, can be larger than unity. This implies that the attenuation of a guided wave propagating in a waveguide immersed in an absorptive medium can be made larger than that of

  12. High speed optical networks

    Science.gov (United States)

    Frankel, Michael Y.; Livas, Jeff

    2005-02-01

    This overview will discuss core network technology and cost trade-offs inherent in choosing between "analog" architectures with high optical transparency, and ones heavily dependent on frequent "digital" signal regeneration. The exact balance will be related to the specific technology choices in each area outlined above, as well as the network needs such as node geographic spread, physical connectivity patterns, and demand loading. Over the course of a decade, optical networks have evolved from simple single-channel SONET regenerator-based links to multi-span multi-channel optically amplified ultra-long haul systems, fueled by high demand for bandwidth at reduced cost. In general, the cost of a well-designed high capacity system is dominated by the number of optical to electrical (OE) and electrical to optical (EO) conversions required. As the reach and channel capacity of the transport systems continued to increase, it became necessary to improve the granularity of the demand connections by introducing (optical add/drop multiplexers) OADMs. Thus, if a node requires only small demand connectivity, most of the optical channels are expressed through without regeneration (OEO). The network costs are correspondingly reduced, partially balanced by the increased cost of the OADM nodes. Lately, the industry has been aggressively pursuing a natural extension of this philosophy towards all-optical "analog" core networks, with each demand touching electrical digital circuitry only at the in/egress nodes. This is expected to produce a substantial elimination of OEO costs, increase in network capacity, and a notionally simpler operation and service turn-up. At the same time, such optical "analog" network requires a large amount of complicated hardware and software for monitoring and manipulating high bit rate optical signals. New and more complex modulation formats that provide resiliency to both optical noise and nonlinear propagation effects are important for extended

  13. Ultra high sensitivity, room temperature magneto-optic field sensor made of ferromagnetic bismuth rare-earth iron garnet thick films

    Science.gov (United States)

    Wu, Dong Ho; Garzarella, Anthony; Fratello, Vince

    2011-03-01

    The ferrimagnetic bismuth rare-earth iron garnet (BiGdLu)3 (FeGa)5 O12 thick film has a specific Faraday rotation θS of 0.09 °/mm at 1550 nm and excellent transparency at infrared wavelengths. Using the thick film we recently have demonstrated a magneto-optic (MO) field sensor with a sensitivity of about 10-14 T/ Hz 1/2 , comparable with SQUID. The sensor is made of all dielectric materials including the bismuth rare-earth iron garnet and optical fibers, and is operated at room temperature without any cooling requirement. The MO field sensor is capable to measure a magnetic field over a very large dynamic range (from a very weak field to a very high magnetic field exceeding several hundred Tesla) and over a very wide frequency range, which may be from DC to a few hundred GHz. However, presently, our MO sensor's frequency range is limited from DC to 2 GHz. We think that this limited frequency range is due to the presence of magnetic domains in the bismuth rare-earth iron garnet film. In this presentation we will report our experimental results obtained from this MO field sensor as well as the effect of magnetic domains.

  14. Polarization sensitive optical coherence tomography detection method

    Energy Technology Data Exchange (ETDEWEB)

    Everett, M J; Sathyam, U S; Colston, B W; DaSilva, L B; Fried, D; Ragadio, J N; Featherstone, J D B

    1999-05-12

    This study demonstrates the potential of polarization sensitive optical coherence tomography (PS-OCT) for non-invasive in vivo detection and characterization of early, incipient caries lesions. PS-OCT generates cross-sectional images of biological tissue while measuring the effect of the tissue on the polarization state of incident light. Clear discrimination between regions of normal and demineralized enamel is first shown in PS-OCT images of bovine enamel blocks containing well-characterized artificial lesions. High-resolution, cross-sectional images of extracted human teeth are then generated that clearly discriminate between the normal and carious regions on both the smooth and occlusal surfaces. Regions of the teeth that appeared to be demineralized in the PS-OCT images were verified using histological thin sections examined under polarized light microscopy. The PS-OCT system discriminates between normal and carious regions by measuring the polarization state of the back-scattered 1310 nm light, which is affected by the state of demineralization of the enamel. Demineralization of enamel increases the scattereing coefficient, thus depolarizing the incident light. This study shows that PS-OCT has great potential for the detection, characterization, and monitoring of incipient caries lesions.

  15. Nonclassical characteristic functions for highly sensitive measurements

    CERN Document Server

    Richter, T; Richter, Th.

    2007-01-01

    Characteristic functions are shown to be useful for highly sensitive measurements. Redistributions of motional Fock states of a trapped atom can be directly monitored via the most fragile nonclassical part of the characteristic function. The method can also be used for decoherence measurements in optical quantum-information systems.

  16. High Sensitivity deflection detection of nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Sanii, Babak; Ashby, Paul

    2009-10-28

    A critical limitation of nanoelectromechanical systems (NEMS) is the lack of a high-sensitivity position detection mechanism. We introduce a noninterferometric optical approach to determine the position of nanowires with a high sensitivity and bandwidth. Its physical origins and limitations are determined by Mie scattering analysis. This enables a dramatic miniaturization of detectable cantilevers, with attendant reductions to the fundamental minimum force noise in highly damping environments. We measure the force noise of an 81{+-}9??nm radius Ag{sub 2}Ga nanowire cantilever in water at 6{+-}3??fN/{radical}Hz.

  17. Novel optical sensing film based on a functional nonwoven nanofibre mat for an easy, fast and highly selective and sensitive detection of tryptamine in beer.

    Science.gov (United States)

    Ramon-Marquez, Teresa; Medina-Castillo, Antonio L; Fernandez-Gutierrez, Alberto; Fernandez-Sanchez, Jorge F

    2016-05-15

    In this paper, the combination of Solid Surface-Room Temperature Phosphorescence (SS-RTP) and nanotechnology has led to a new approach in the detection of biogenic amines in complex matrices. This novel approach allows, for the first time, the direct determination of the concentration of tryptamine in beers. The novelty of the proposed optical sensor resides in its simplicity, rapidity, absence of complex chromatographic separation, sample clean-up, preconcentration, and derivatization protocols. Therefore, this novel methodology simplifies and reduces considerably the time and cost of the analysis, resolving the two major problems of the determination of tryptamine in beer up to now: low sensitivity and matrix effects. The proposed sensor is based on a novel white, uncharged, and non-luminescent functional nonwoven nanofibre mat (Tiss®-Link) formed by hydrophilic nanofibres of 300 nm of diameter functionalized with a high concentration of active vinyl groups (330 µmol g(-1)). It is used to carry out a kinetically controlled covalent immobilisation of tryptamine via Michael type-reaction. The transduction of the sensor is phosphorescence; the covalently immobilized tryptamine is quantified by SS-RTP, obtaining a detection limit of 6 ng mL(-1) with short response times (15 min). The applicability of the sensor was demonstrated by analysing tryptamine in 10 different varieties of beers, obtaining recovery percentages close to 100%.

  18. Polarization properties of single layers in the posterior eyes of mice and rats investigated using high resolution polarization sensitive optical coherence tomography.

    Science.gov (United States)

    Fialová, Stanislava; Augustin, Marco; Glösmann, Martin; Himmel, Tanja; Rauscher, Sabine; Gröger, Marion; Pircher, Michael; Hitzenberger, Christoph K; Baumann, Bernhard

    2016-04-01

    We present a high resolution polarization sensitive optical coherence tomography (PS-OCT) system for ocular imaging in rodents. The system operates at 840 nm and uses a broadband superluminescent diode providing an axial resolution of 5.1 µm in air. PS-OCT data was acquired at 83 kHz A-scan rate by two identical custom-made spectrometers for orthogonal polarization states. Pigmented (Brown Norway, Long Evans) and non-pigmented (Sprague Dawley) rats as well as pigmented mice (C57BL/6) were imaged. Melanin pigment related depolarization was analyzed in the retinal pigment epithelium (RPE) and choroid of these animals using the degree of polarization uniformity (DOPU). For all rat strains, significant differences between RPE and choroidal depolarization were observed. In contrast, DOPU characteristics of RPE and choroid were similar for C57BL/6 mice. Moreover, the depolarization within the same tissue type varied significantly between different rodent strains. Retinal nerve fiber layer thickness, phase retardation, and birefringence were mapped and quantitatively measured in Long Evans rats in vivo for the first time. In a circumpapillary annulus, retinal nerve fiber layer birefringence amounted to 0.16°/µm ± 0.02°/µm and 0.17°/µm ± 0.01°/µm for the left and right eyes, respectively.

  19. High Dynamics and Precision Optical Measurement Using a Position Sensitive Detector (PSD in Reflection-Mode: Application to 2D Object Tracking over a Smart Surface

    Directory of Open Access Journals (Sweden)

    Ioan Alexandru Ivan

    2012-12-01

    Full Text Available When related to a single and good contrast object or a laser spot, position sensing, or sensitive, detectors (PSDs have a series of advantages over the classical camera sensors, including a good positioning accuracy for a fast response time and very simple signal conditioning circuits. To test the performance of this kind of sensor for microrobotics, we have made a comparative analysis between a precise but slow video camera and a custom-made fast PSD system applied to the tracking of a diffuse-reflectivity object transported by a pneumatic microconveyor called Smart-Surface. Until now, the fast system dynamics prevented the full control of the smart surface by visual servoing, unless using a very expensive high frame rate camera. We have built and tested a custom and low cost PSD-based embedded circuit, optically connected with a camera to a single objective by means of a beam splitter. A stroboscopic light source enhanced the resolution. The obtained results showed a good linearity and a fast (over 500 frames per second response time which will enable future closed-loop control by using PSD.

  20. High dynamics and precision optical measurement using a position sensitive detector (PSD) in reflection-mode: application to 2D object tracking over a Smart Surface.

    Science.gov (United States)

    Ivan, Ioan Alexandru; Ardeleanu, Mihai; Laurent, Guillaume J

    2012-12-06

    When related to a single and good contrast object or a laser spot, position sensing, or sensitive, detectors (PSDs) have a series of advantages over the classical camera sensors, including a good positioning accuracy for a fast response time and very simple signal conditioning circuits. To test the performance of this kind of sensor for microrobotics, we have made a comparative analysis between a precise but slow video camera and a custom-made fast PSD system applied to the tracking of a diffuse-reflectivity object transported by a pneumatic microconveyor called Smart-Surface. Until now, the fast system dynamics prevented the full control of the smart surface by visual servoing, unless using a very expensive high frame rate camera. We have built and tested a custom and low cost PSD-based embedded circuit, optically connected with a camera to a single objective by means of a beam splitter. A stroboscopic light source enhanced the resolution. The obtained results showed a good linearity and a fast (over 500 frames per second) response time which will enable future closed-loop control by using PSD.

  1. High-Sensitivity Magnetization Measurements

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The three most common instruments for high-sensitivity magnetization measurements (the vibrating-sample magnetometer, the alternating gradient magnetometer, and the SQUID magne tometer) are described and their limiting sensitivities are discussed. The advantages and disad vantages of each are described. Magnetometers using micro-machined force detectors are briefly mentioned.

  2. Detection of disease-associated prion protein in the optic nerve and the adrenal gland of cattle with bovine spongiform encephalopathy by using highly sensitive immunolabeling procedures.

    Science.gov (United States)

    Okada, Hiroyuki; Iwamaru, Yoshifumi; Fukuda, Shigeo; Yokoyama, Takashi; Mohri, Shirou

    2012-04-01

    A sensitive immunohistochemical procedure, the tyramide signal amplification (TSA) system, was applied to detect the localization of immunolabeled disease-associated prion protein (PrP(Sc)) in cattle affected with bovine spongiform encephalopathy (BSE). In this procedure, immunolabeling could be visualized in the optic nerve and the adrenal medulla. In the optic nerve, the dual immunofluorescent technique showed that the granular PrP(Sc) was occasionally detected in the astrocytes, microglia, and myelin sheath adjacent to the axon. Clustered PrP(Sc) was also scattered in association with microglial cells and astrocytes of the optic nerve. In the adrenal gland, PrP(Sc) immunolabeling was confined within the sympathetic nerve fibers and endings. The results suggest that (1) PrP(Sc) might centrifugally spread within and between glial cells and/or the non-axonal (also known as ad-axonal) region of nerve fibers, rather than the axonal and/or extracellular space pathway in the optic nerve, and (2) the sympathetic innervations might be important for the trafficking of BSE agent in the adrenal glands of cattle. This study also suggests that tyramide-based immunochemical analysis should be performed to detect immunolabeled PrP(Sc) in the extracerebral tissues of BSE-affected cattle.

  3. Label-free and highly sensitive optical imaging of detailed microcirculation within meninges and cortex in mice with the cranium left intact

    Science.gov (United States)

    Jia, Yali; An, Lin; Wang, Ruikang K.

    2010-05-01

    We demonstrate for the first time that the detailed blood flow distribution within intracranial dura mater and cortex can be visualized by an ultrahigh sensitive optical microangiography (UHS-OMAG). The study uses an UHS-OMAG system operating at 1310 nm with an imaging speed at 150 frames per second that requires ~10 s to complete one 3-D scan of ~2.5×2.5 mm2. The system is sensitive to blood flow with a velocity ranging from ~4 μm/s to ~23 mm/s. We show superior performance of UHS-OMAG in providing functional images of capillary level microcirculation within meninges in mice with the cranium left intact, the results of which correlate well with the standard dural histopathology.

  4. Frequency range selection method of trans-impedance amplifier for high sensitivity lock-in amplifier used in the optical sensors

    Science.gov (United States)

    Park, Chang-In; Jeon, Su-Jin; Hong, Nam-Pyo; Choi, Young-Wan

    2016-03-01

    Lock-in amplifier (LIA) has been proposed as a detection technique for optical sensors because it can measure low signal in high noise level. LIA uses synchronous method, so the input signal frequency is locked to a reference frequency that is used to carry out the measurements. Generally, input signal frequency of LIA used in optical sensors is determined by modulation frequency of optical signal. It is important to understand the noise characteristics of the trans-impedance amplifier (TIA) to determine the modulation frequency. The TIA has a frequency range in which noise is minimized by the capacitance of photo diode (PD) and the passive component of TIA feedback network. When the modulation frequency is determined in this range, it is possible to design a robust system to noise. In this paper, we propose a method for the determination of optical signal modulation frequency selection by using the noise characteristics of TIA. Frequency response of noise in TIA is measured by spectrum analyzer and minimum noise region is confirmed. The LIA and TIA circuit have been designed as a hybrid circuit. The optical sensor is modeled by the laser diode (LD) and photo diode (PD) and the modulation frequency was used as the input to the signal generator. The experiments were performed to compare the signal to noise ratio (SNR) of the minimum noise region and the others. The results clearly show that the SNR is enhanced in the minimum noise region of TIA.

  5. On the sensitivity of generic porous optical sensors

    CERN Document Server

    Mackay, Tom G

    2012-01-01

    A porous material was considered as a platform for optical sensing. It was envisaged that the porous material was infiltrated by a fluid which contains an agent to be sensed. Changes in the optical properties of the infiltrated porous material provide the basis for detection of the agent to be sensed. Using a homogenization approach based on the Bruggeman formalism, wherein the infiltrated porous material was regarded as a homogenized composite material, the sensitivity of such a sensor was investigated. For the case of an isotropic dielectric porous material of relative permittivity $\\epsilon^a$ and an isotropic dielectric fluid of relative permittivity $\\epsilon^b$, it was found that the sensitivity was maximized when there was a large contrast between $\\epsilon^a$ and $\\epsilon^b$; the maximum sensitivity was achieved at mid-range values of porosity. Especially high sensitivities may be achieved for $\\epsilon^b$ close to unity when $\\epsilon^a >> 1$, for example. Furthermore, higher sensitivities may be ac...

  6. Ultra-sensitive Magnetic Microscopy with an Optically Pumped Magnetometer

    Science.gov (United States)

    Kim, Young Jin; Savukov, Igor

    2016-04-01

    Optically pumped magnetometers (OPMs) based on lasers and alkali-metal vapor cells are currently the most sensitive non-cryogenic magnetic field sensors. Many applications in neuroscience and other fields require high-resolution, high-sensitivity magnetic microscopic measurements. In order to meet this demand we combined a cm-size spin-exchange relaxation-free (SERF) OPM and flux guides (FGs) to realize an ultra-sensitive FG-OPM magnetic microscope. The FGs serve to transmit the target magnetic flux to the OPM thus improving both the resolution and sensitivity to small magnetic objects. We investigated the performance of the FG-OPM device using experimental and numerical methods, and demonstrated that an optimized device can achieve a unique combination of high resolution (80 μm) and high sensitivity (8.1 pT/). In addition, we also performed numerical calculations of the magnetic field distribution in the FGs to estimate the magnetic noise originating from the domain fluctuations in the material of the FGs. We anticipate many applications of the FG-OPM device such as the detection of micro-biological magnetic fields; the detection of magnetic nano-particles; and non-destructive testing. From our theoretical estimate, an FG-OPM could detect the magnetic field of a single neuron, which would be an important milestone in neuroscience.

  7. Ultra-sensitive Magnetic Microscopy with an Optically Pumped Magnetometer.

    Science.gov (United States)

    Kim, Young Jin; Savukov, Igor

    2016-04-22

    Optically pumped magnetometers (OPMs) based on lasers and alkali-metal vapor cells are currently the most sensitive non-cryogenic magnetic field sensors. Many applications in neuroscience and other fields require high-resolution, high-sensitivity magnetic microscopic measurements. In order to meet this demand we combined a cm-size spin-exchange relaxation-free (SERF) OPM and flux guides (FGs) to realize an ultra-sensitive FG-OPM magnetic microscope. The FGs serve to transmit the target magnetic flux to the OPM thus improving both the resolution and sensitivity to small magnetic objects. We investigated the performance of the FG-OPM device using experimental and numerical methods, and demonstrated that an optimized device can achieve a unique combination of high resolution (80 μm) and high sensitivity (8.1 pT/). In addition, we also performed numerical calculations of the magnetic field distribution in the FGs to estimate the magnetic noise originating from the domain fluctuations in the material of the FGs. We anticipate many applications of the FG-OPM device such as the detection of micro-biological magnetic fields; the detection of magnetic nano-particles; and non-destructive testing. From our theoretical estimate, an FG-OPM could detect the magnetic field of a single neuron, which would be an important milestone in neuroscience.

  8. Optical Sensitivity Gain in Silica-Coated Plasmonic Nanostructures.

    Science.gov (United States)

    Floris, Francesco; Figus, Cristiana; Fornasari, Lucia; Patrini, Maddalena; Pellacani, Paola; Marchesini, Gerardo; Valsesia, Andrea; Artizzu, Flavia; Marongiu, Daniela; Saba, Michele; Mura, Andrea; Bongiovanni, Giovanni; Marabelli, Franco; Quochi, Francesco

    2014-09-04

    Ultrathin films of silica realized by sol-gel synthesis and dip-coating techniques were successfully applied to predefined metal/polymer plasmonic nanostructures to spectrally tune their resonance modes and to increase their sensitivity to local refractive index changes. Plasmon resonance spectral shifts up to 100 nm with slope efficiencies of ∼8 nm/nm for increasing layer thickness were attained. In the ultrathin layer regime (<10 nm), which could be reached by suitable dilution of the silica precursors and optimization of the deposition speed, the sensitivity of the main plasmonic resonance to refractive index changes in aqueous solution could be increased by over 50% with respect to the bare plasmonic chip. Numerical simulations supported experimental data and unveiled the mechanism responsible for the optical sensitivity gain, proving an effective tool in the design of high-performance plasmonic sensors.

  9. A porous silicon optical microcavity for sensitive bacteria detection

    Energy Technology Data Exchange (ETDEWEB)

    Li Sha; Huang Jianfeng; Cai Lintao, E-mail: lt.cai@siat.ac.cn [CAS Key Lab of Health Informatics, Shenzhen Key Laboratory of Cancer Nanotechnology, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055 (China)

    2011-10-21

    A porous silicon microcavity (PSM) is highly sensitive to subtle interface changes due to its high surface area, capillary condensation ability and a narrow resonance peak ({approx}10 nm). Based on the well-defined optical properties of a PSM, we successfully fabricated a bacteria detection chip for molecular or subcellular analysis by surface modification using undecylenic acid (UA), and the specific recognition binding of vancomycin to the D-alanyl-D-alanine of bacteria. The red shift of the PSM resonance peak showed a good linear relationship with bacteria concentration ranging from 100 to 1000 bacteria ml{sup -1} at the level of relative standard deviation of 0.994 and detection limit of 20 bacteria ml{sup -1}. The resulting PSM sensors demonstrated high sensitivity, good reproducibility, fast response and low cost for biosensing.

  10. Static sensitivity calculation of a novel fiber optic biosensor

    Institute of Scientific and Technical Information of China (English)

    Zhongchen Bai; Shuijie Qin; Jing Li; Dashun Huang; Xin Zhang

    2008-01-01

    A novel structure of fiber optic biosensor and its principle are introduced. The sample is detected in microchannels of several microns diameter in fiber optic biosensors. The relation between the optic fiber tapered angle and the fluorescence incident angle is calculated in signal receiving part. As the sensor is a zero-order system, calculating formula of the static sensitivity is derived. When ZnSe nano-crystalline cluster is used for marking the molecules, the static sensitivity for fiber optic biosensors is calculated. At the same time, the relation between the static sensitivity and the ratio of exciting wavelength to fluorescence wavelength is presented.

  11. High pressure optical combustion probe

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, S.D.; Richards, G.A.

    1995-06-01

    The Department of Energy`s Morgantown Energy Technology Center has developed a combustion probe for monitoring flame presence and heat release. The technology involved is a compact optical detector of the OH radical`s UV fluorescence. The OH Monitor/Probe is designed to determine the flame presence and provide a qualitative signal proportional to the flame intensity. The probe can be adjusted to monitor a specific volume in the combustion zone to track spatial fluctuations in the flame. The probe is capable of nanosecond time response and is usually slowed electronically to fit the flame characteristics. The probe is a sapphire rod in a stainless steel tube which may be inserted into the combustion chamber and pointed at the flame zone. The end of the sapphire rod is retracted into the SS tube to define a narrow optical collection cone. The collection cone may be adjusted to fit the experiment. The fluorescence signal is collected by the sapphire rod and transmitted through a UV transmitting, fused silica, fiber optic to the detector assembly. The detector is a side window photomultiplier (PMT) with a 310 run line filter. A Hamamatsu photomultiplier base combined with a integral high voltage power supply permits this to be a low voltage device. Electronic connections include: a power lead from a modular DC power supply for 15 VDC; a control lead for 0-1 volts to control the high voltage level (and therefore gain); and a lead out for the actual signal. All low voltage connections make this a safe and easy to use device while still delivering the sensitivity required.

  12. Xanthine oxidase functionalized Ta2O5 nanostructures as a novel scaffold for highly sensitive SPR based fiber optic xanthine sensor.

    Science.gov (United States)

    Kant, Ravi; Tabassum, Rana; Gupta, Banshi D

    2018-01-15

    Fabrication and characterization of a surface plasmon resonance based fiber optic xanthine sensor using entrapment of xanthine oxidase (XO) enzyme in several nanostructures of tantalum (v) oxide (Ta2O5) have been reported. Chemical route was adopted for synthesizing Ta2O5 nanoparticles, nanorods, nanotubes and nanowires while Ta2O5 nanofibers were prepared by electrospinning technique. The synthesized Ta2O5 nanostructures were characterized by photoluminescence, scanning electron microscopy, UV-Visible spectra and X-ray diffraction pattern. The probes were fabricated by coating an unclad core of the fiber with silver layer followed by the deposition of XO entrapped Ta2O5 nanostructures. The crux of sensing mechanism relies on the modification of dielectric function of sensing layer upon exposure to xanthine solution of diverse concentrations, reflected in terms of shift in resonance wavelength. The sensing probe coated with XO entrapped Ta2O5 nanofibers has been turned out to possess maximum sensitivity amongst the synthesized nanostructures. The probe was optimized in terms of pH of the sample and the concentration of XO entrapped in Ta2O5 nanofibers. The optimized sensing probe possesses a remarkably good sensitivity of 26.2nm/µM in addition to linear range from 0 to 3µM with an invincible LOD value of 0.0127µM together with a response time of 1min. Furthermore, probe selectivity with real sample analysis ensure the usage of the sensor for practical scenario. The results reported open a novel perspective towards a sensitive, rapid, reliable and selective detection of xanthine. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Novel D-π-A-π-A coumarin dyes for highly efficient dye-sensitized solar cells: Effect of π-bridge on optical, electrochemical, and photovoltaic performance

    Science.gov (United States)

    Feng, Haijing; Li, Ranran; Song, Yicong; Li, Xiaoyan; Liu, Bo

    2017-03-01

    The direct connection of coumarin and auxiliary acceptor in D-A-π-A construction will cause large dihedral angle between these two planes, thus affecting the intramolecular charge transfer process. Herein, with an additional π-bridge between coumarin and auxiliary acceptor, two novel coumarin sensitizers, CS-1 and CS-2, based on D-π-A-π-A construction have been designed and synthesized. With this modification, the planarity of donor-to-auxiliary acceptor part is effectively improved, thus resulting in smoother ICT process and less energy loss. Along with the planarization of molecule, the energy levels of the dyes are also effectively optimized. Moreover, the introduction of additional π-bridge will not affect the photostability of the dye. Accordingly, a record high PCE of 8.03% is obtained by CS-2 sensitized DSSCs, with a JSC of 16.38 mA cm-2, a VOC of 694 mV, and a ff of 0.707, while only around 3.5% decline in PCE is found after 1000 h aging test. Our results demonstrate that good planarity is obviously preferred to optimize the energy level and photovoltaic performance of sensitizer, providing a powerful strategy for the development of highly efficient organic sensitizers in the future.

  14. Holographic optical elements recorded in silver halide sensitized gelatin emulsions. Part I. Transmission holographic optical elements.

    Science.gov (United States)

    Kim, J M; Choi, B S; Kim, S I; Kim, J M; Bjelkhagen, H I; Phillips, N J

    2001-02-10

    Silver halide sensitized gelatin (SHSG) holograms are similar to holograms recorded in dichromated gelatin (DCG), the main recording material for holographic optical elements (HOE's). The drawback of DCG is its low sensitivity and limited spectral response. Silver halide materials can be processed in such a way that the final hologram will have properties like a DCG hologram. Recently this technique has become more interesting since the introduction of new ultra-high-resolution silver halide emulsions. An optimized processing technique for transmission HOE's recorded in these materials is introduced. Diffraction efficiencies over 90% can be obtained for transmissive diffraction gratings. Understanding the importance of the selective hardening process has made it possible to obtain results similar to conventional DCG processing. The main advantage of the SHSG process is that high-sensitivity recording can be performed with laser wavelengths anywhere within the visible spectrum. This simplifies the manufacturing of high-quality, large-format HOE's.

  15. Study of influence of the fiber optic coatings parameters on optical acoustic sensitivity

    Science.gov (United States)

    Lavrov, V. S.; Kulikov, A. V.; Plotnikov, M. U.; Efimov, M. E.; Varzhel, S. V.

    2016-08-01

    The paper presents the optical fiber acoustic sensitivity dependence on the coating parameters and the thickness of coating layer. A comparison of data obtained from the theoretical research and experimental estimates of real samples sensitivity in air and water.

  16. Phase-sensitive optical processing in silicon waveguides

    DEFF Research Database (Denmark)

    Petermann, Klaus; Gajda, A.; Dziallas, Claudia

    2015-01-01

    Parametric optical signal processing is reviewed for silicon nano-rib-waveguides with a reverse-biased pin-junction. Phase-sensitive parametric amplification with a phase-sensitive extinction of more than 20 dB has been utilized for the regeneration of DPSK signals......Parametric optical signal processing is reviewed for silicon nano-rib-waveguides with a reverse-biased pin-junction. Phase-sensitive parametric amplification with a phase-sensitive extinction of more than 20 dB has been utilized for the regeneration of DPSK signals...

  17. Sensitivity of optical mass sensor enhanced by optomechanical coupling

    Energy Technology Data Exchange (ETDEWEB)

    He, Yong, E-mail: hey@cczu.edu.cn [School of Mathematics and Physics, Changzhou University, Changzhou 213164 (China)

    2015-03-23

    Optical mass sensors based on cavity optomechanics employ radiation pressure force to drive mechanical resonator whose mechanical susceptibility can be described by nonlinear optical transmission spectrum. In this paper, we present an optical mass sensor based on a two-cavity optomechanical system where the mechanical damping rate can be decreased by adjusting a pump power so that the mass sensitivity which depends on the mechanical quality factor has been enhanced greatly. Compared with that of an optical mass sensor based on single-cavity optomechanics, the mass sensitivity of the optical mass sensor is improved by three orders of magnitude. This is an approach to enhance the mass sensitivity by means of optomechanical coupling, which is suitable for all mass sensor based on cavity optomechanics. Finally, we illustrate the accurate measurement for the mass of a few chromosomes, which can be achieved based on the current experimental conditions.

  18. Polarisation-sensitive optical elements in azobenzene polyesters and peptides

    DEFF Research Database (Denmark)

    Ramanujam, P.S.; Dam-Hansen, Carsten; Berg, Rolf Henrik;

    2006-01-01

    In this article, we describe fabrication of polarisation holographic optical elements in azobenzene polyesters. Both liquid crystalline and amorphous side-chain polyesters have been utilised. Diffractive optical elements such as lenses and gratings that are sensitive to the polarisation...... of the incident light have been fabricated with polarisation holography. Computer-generated optical elements and patterns have also been written with a single polarised laser beam. Recording of polarisation defects enabling easy visualisation is also shown to be feasible in azobenzene polyesters....

  19. Polarization-Sensitive Quantum Optical Coherence Tomography: Experiment

    CERN Document Server

    Booth, Mark C; Teich, Malvin Carl

    2010-01-01

    Polarization-sensitive quantum optical coherence tomography (PS-QOCT) makes use of a Type-II twin-photon light source for carrying out optical sectioning with polarization sensitivity. A BBO nonlinear optical crystal pumped by a Ti:sapphire psec-pulsed laser is used to confirm the theoretical underpinnings of this imaging paradigm. PS-QOCT offers even-order dispersion cancellation with simultaneous access to the group-velocity dispersion characteristics of the interstitial medium between the reflecting surfaces of the sample.

  20. Technical note: Sensitivity of instrumental line shape monitoring for the ground-based high-resolution FTIR spectrometer with respect to different optical attenuators

    Science.gov (United States)

    Sun, Youwen; Palm, Mathias; Weinzierl, Christine; Petri, Christof; Notholt, Justus; Wang, Yuting; Liu, Cheng

    2017-03-01

    The TCCON (Total Carbon Column Observing Network) and most NDACC (Network for Detection of Atmospheric Composition Change) sites assume an ideal ILS (instrumental line shape) for analysis of the spectra. In order to adapt the radiant energy received by the detector, an attenuator or different sizes of field stop can be inserted in the light path. These processes may alter the alignment of a high-resolution FTIR (Fourier transform infrared) spectrometer, and may result in bias due to ILS drift. In this paper, we first investigated the sensitivity of the ILS monitoring with respect to application of different kinds of attenuators for ground-based high-resolution FTIR spectrometers within the TCCON and NDACC networks. Both lamp and sun cell measurements were conducted after the insertion of five different attenuators in front of and behind the interferometer. The ILS characteristics derived from lamp and sun spectra are in good agreement. ILSs deduced from all lamp cell measurements were compared. As a result, the disturbances to the ILS of a high-resolution FTIR spectrometer with respect to the insertion of different attenuators at different positions were quantified. A potential strategy to adapt the incident intensity of a detector was finally deduced.

  1. Optically sensitive Medipix2 detector for adaptive optics wavefront sensing

    CERN Document Server

    Vallerga, John; Tremsina, Anton; Siegmund, Oswald; Mikulec, Bettina; Clark, Allan G; CERN. Geneva

    2005-01-01

    A new hybrid optical detector is described that has many of the attributes desired for the next generation adaptive optics (AO) wavefront sensors. The detector consists of a proximity focused microchannel plate (MCP) read out by multi-pixel application specific integrated circuit (ASIC) chips developed at CERN ("Medipix2") with individual pixels that amplify, discriminate and count input events. The detector has 256 x 256 pixels, zero readout noise (photon counting), can be read out at 1 kHz frame rates and is abutable on 3 sides. The Medipix2 readout chips can be electronically shuttered down to a temporal window of a few microseconds with an accuracy of 10 ns. When used in a Shack-Hartmann style wavefront sensor, a detector with 4 Medipix chips should be able to centroid approximately 5000 spots using 7 x 7 pixel sub-apertures resulting in very linear, off-null error correction terms. The quantum efficiency depends on the optical photocathode chosen for the bandpass of interest.

  2. High sensitivity RNA pseudoknot prediction

    OpenAIRE

    Huang, Xiaolu; Ali, Hesham

    2006-01-01

    Most ab initio pseudoknot predicting methods provide very few folding scenarios for a given RNA sequence and have low sensitivities. RNA researchers, in many cases, would rather sacrifice the specificity for a much higher sensitivity for pseudoknot detection. In this study, we introduce the Pseudoknot Local Motif Model and Dynamic Partner Sequence Stacking (PLMM_DPSS) algorithm which predicts all PLM model pseudoknots within an RNA sequence in a neighboring-region-interference-free fashion. T...

  3. All-optical WDM Regeneration of DPSK Signals using Optical Fourier Transformation and Phase Sensitive Amplification

    DEFF Research Database (Denmark)

    Guan, Pengyu; Røge, Kasper Meldgaard; Kjøller, Niels-Kristian;

    2015-01-01

    We propose a novel all-optical WDM regeneration scheme for DPSK signals based on optical Fourier transformation and phase sensitive amplification. Phase regeneration of a WDM signal consisting of 4x10-Gbit/s phase noise degraded DPSK channels is demonstrated for the first time.......We propose a novel all-optical WDM regeneration scheme for DPSK signals based on optical Fourier transformation and phase sensitive amplification. Phase regeneration of a WDM signal consisting of 4x10-Gbit/s phase noise degraded DPSK channels is demonstrated for the first time....

  4. Miniaturization of a micro-optics array for highly sensitive and parallel detection on an injection moulded lab-on-a-chip

    DEFF Research Database (Denmark)

    Hung, Tran Quang; Sun, Yi; Poulsen, Carl Esben

    2015-01-01

    A miniaturised array of supercritical angle fluorescence (SAF) micro-optics embedded in a microfluidic chamber was fabricated by injection moulding. The fabricated chip could enhance the fluorescence signal around 46 times compared to a conventional microscope. Collection of the fluorescence signal...

  5. Single mode variable-sensitivity fiber optic sensors

    Science.gov (United States)

    Murphy, K. A.; Fogg, B. R.; Gunther, M. F.; Claus, R. O.

    1992-01-01

    We review spatially-weighted optical fiber sensors that filter specific vibration modes from one dimensional beams placed in clamped-free and clamped-clamped configurations. The sensitivity of the sensor is varied along the length of the fiber by tapering circular-core, dual-mode optical fibers. Selective vibration mode suppression on the order of 10 dB was obtained. We describe experimental results and propose future extensions to single mode sensor applications.

  6. High-speed optical frequency-domain imaging

    OpenAIRE

    Yun, S. H.; Tearney, G. J.; Boer; Iftimia, N. V.; Bouma, B. E.

    2003-01-01

    We demonstrate high-speed, high-sensitivity, high-resolution optical imaging based on optical frequency-domain interferometry using a rapidly-tuned wavelength-swept laser. We derive and show experimentally that frequency-domain ranging provides a superior signal-to-noise ratio compared with conventional time-domain ranging as used in optical coherence tomography. A high sensitivity of −110 dB was obtained with a 6 mW source at an axial resolution of 13.5 µm and an A-line rate of 15.7 kHz, rep...

  7. Phase-sensitive multiple reference optical coherence tomography (Conference Presentation)

    Science.gov (United States)

    Dsouza, Roshan I.; Subhash, Hrebesh; Neuhaus, Kai; Hogan, Josh; Wilson, Carol; Leahy, Martin

    2016-03-01

    Multiple reference OCT (MR-OCT) is a recently developed novel time-domain OCT platform based on a miniature reference arm optical delay, which utilizes a single miniature actuator and a partial mirror to generate recirculating optical delay for extended axial-scan range. MR-OCT technology promises to fit into a robust and cost-effective design, compatible with integration into consumer-level devices for addressing wide applications in mobile healthcare and biometry applications. Using conventional intensity based OCT processing techniques, the high-resolution structural imaging capability of MR-OCT has been recently demonstrated for various applications including in vivo human samples. In this study, we demonstrate the feasibility of implementing phase based processing with MR-OCT for various functional applications such as Doppler imaging and sensing of blood vessels, and for tissue vibrography applications. The MR-OCT system operates at 1310nm with a spatial resolution of ~26 µm and an axial scan rate of 600Hz. Initial studies show a displacement-sensitivity of ~20 nm to ~120 nm for the first 1 to 9 orders of reflections, respectively with a mirror as test-sample. The corresponding minimum resolvable velocity for these orders are ~2.3 µm/sec and ~15 µm/sec respectively. Data from a chick chorioallantoic membrane (CAM) model will be shown to demonstrate the feasibility of MR-OCT for imaging in-vivo blood flow.

  8. Sensitivity of quantum-dot semiconductor lasers to optical feedback.

    Science.gov (United States)

    O'Brien, D; Hegarty, S P; Huyet, G; Uskov, A V

    2004-05-15

    The sensitivity of quantum-dot semiconductor lasers to optical feedback is analyzed with a Lang-Kobayashi approach applied to a standard quantum-dot laser model. The carriers are injected into a quantum well and are captured by, or escape from, the quantum dots through either carrier-carrier or phonon-carrier interaction. Because of Pauli blocking, the capture rate into the dots depends on the carrier occupancy level in the dots. Here we show that different carrier capture dynamics lead to a strong modification of the damping of the relaxation oscillations. Regions of increased damping display reduced sensitivity to optical feedback even for a relatively large alpha factor.

  9. High sensitivity RNA pseudoknot prediction.

    Science.gov (United States)

    Huang, Xiaolu; Ali, Hesham

    2007-01-01

    Most ab initio pseudoknot predicting methods provide very few folding scenarios for a given RNA sequence and have low sensitivities. RNA researchers, in many cases, would rather sacrifice the specificity for a much higher sensitivity for pseudoknot detection. In this study, we introduce the Pseudoknot Local Motif Model and Dynamic Partner Sequence Stacking (PLMM_DPSS) algorithm which predicts all PLM model pseudoknots within an RNA sequence in a neighboring-region-interference-free fashion. The PLM model is derived from the existing Pseudobase entries. The innovative DPSS approach calculates the optimally lowest stacking energy between two partner sequences. Combined with the Mfold, PLMM_DPSS can also be used in predicting complicated pseudoknots. The test results of PLMM_DPSS, PKNOTS, iterated loop matching, pknotsRG and HotKnots with Pseudobase sequences have shown that PLMM_DPSS is the most sensitive among the five methods. PLMM_DPSS also provides manageable pseudoknot folding scenarios for further structure determination.

  10. Sensitive optical biosensors for unlabeled targets: A review

    Energy Technology Data Exchange (ETDEWEB)

    Fan Xudong [Department of Biological Engineering, University of Missouri, 240D, Bond Life Sciences Center, 1201 E. Rollins Street, Columbia, Missouri 65211 (United States)], E-mail: fanxud@missouri.edu; White, Ian M.; Shopova, Siyka I.; Zhu Hongying; Suter, Jonathan D.; Sun Yuze [Department of Biological Engineering, University of Missouri, 240D, Bond Life Sciences Center, 1201 E. Rollins Street, Columbia, Missouri 65211 (United States)

    2008-07-14

    This article reviews the recent progress in optical biosensors that use the label-free detection protocol, in which biomolecules are unlabeled or unmodified, and are detected in their natural forms. In particular, it will focus on the optical biosensors that utilize the refractive index change as the sensing transduction signal. Various optical label-free biosensing platforms will be introduced, including, but not limited to, surface plasmon resonance, interferometers, waveguides, fiber gratings, ring resonators, and photonic crystals. Emphasis will be given to the description of optical structures and their respective sensing mechanisms. Examples of detecting various types of biomolecules will be presented. Wherever possible, the sensing performance of each optical structure will be evaluated and compared in terms of sensitivity and detection limit.

  11. Holographic optical elements recorded in silver halide sensitized gelatin emulsions. Part 2. Reflection holographic optical elements.

    Science.gov (United States)

    Kim, Jong Man; Choi, Byung So; Choi, Yoon Sun; Kim, Jong Min; Bjelkhagen, Hans I; Phillips, Nicholas J

    2002-03-10

    Silver halide sensitized gelatin (SHSG) holograms are similar to holograms recorded in dichromated gelatin (DCG), the main recording material for holographic optical elements (HOEs). The drawback of DCG is its low energetic sensitivity and limited spectral response. Silver halide materials can be processed in such away that the final hologram will have properties like a DCG hologram. Recently this technique has become more interesting since the introduction of new ultra-fine-grain silver halide (AgHal) emulsions. In particular, high spatial-frequency fringes associated with HOEs of the reflection type are difficult to construct when SHSG processing methods are employed. Therefore an optimized processing technique for reflection HOEs recorded in the new AgHal materials is introduced. Diffraction efficiencies over 90% can be obtained repeatably for reflection diffraction gratings. Understanding the importance of a selective hardening process has made it possible to obtain results similar to conventional DCG processing. The main advantage of the SHSG process is that high-sensitivity recording can be performed with laser wavelengths anywhere within the visible spectrum. This simplifies the manufacturing of high-quality, large-format HOEs, also including high-quality display holograms of the reflection type in both monochrome and full color.

  12. All-optical control of neuronal function via optical delivery of light-sensitive proteins and optogenetic stimulation

    Science.gov (United States)

    Villalobos, Alex; Gu, Ling; Mohanty, Samarendra

    2012-02-01

    While pulsed laser beams have been used for stimulation of neurons, cellular specificity during optical stimulation is achieved by photo-sensitization of genetically-targeted cells by optogenetic means. However, till date, the process of optogenetic-sensitization primarily involves use of viral vectors. In rare occasions, electroporation has been used. Here, we report an all-optical method in which pulsed laser beam is used for delivery of genes, encoding optogenetic probes, to spatially-targeted cells, followed by optogenetic stimulation and optical detection of the activation process. Use of laser microbeam enabled highly precise spatially-patterned delivery of optogenes, as confirmed by expression of conjugated fluorescent protein. Light-activation of opsin-expressing cells was confirmed by calcium-imaging. The laser-assisted expression of optogenetic probes in spatially-targeted regions in combination with light-assisted activation and optical detection of neural activity will help in better understanding of the neuronal circuitry.

  13. High sensitivity radon emanation measurements.

    Science.gov (United States)

    Zuzel, G; Simgen, H

    2009-05-01

    The presented radon detection technique employs miniaturized ultra-low background proportional counters. (222)Rn samples are purified, mixed with a counting gas and filled into a counter using a special glass vacuum line. The absolute sensitivity of the system is estimated to be 40 microBq (20 (222)Rn atoms). For emanation investigations two metal sealed stainless steel vessels and several glass vials are available. Taking into account their blank contributions, measurements at a minimum detectable activity of about 100 microBq can be performed.

  14. Study of optical properties and proteoglycan content of tendons by polarization sensitive optical coherence tomography

    Science.gov (United States)

    Yang, Ying; Rupani, Asha; Bagnaninchi, Pierre; Wimpenny, Ian; Weightman, Alan

    2012-08-01

    The highly orientated collagen fibers in tendons play a critical role for transferring tensile stress, and they demonstrate birefringent optical properties. However, the influence that proteoglycans (PGs) have on the optical properties of tendons is yet to be fully elucidated. PGs are the essential components of the tendon extracellular matrix; the changes in their quantities and compositions have been associated with tendinopathies. In this study, polarization sensitive optical coherence tomography (PS-OCT) has been used to reveal the relationship between PG content/location and birefringence properties of tendons. Fresh chicken tendons were imaged at regular intervals by PS-OCT and polarization light microscopy during the extraction of PGs, using guanidine hydrochloride (GuHCl). Complementary time-lapsed images taken from the two modalities mutually demonstrated that the extraction of PGs disturbed the local organization of collagen bundles. This corresponded with a decrease in birefringence and associated banding pattern observed by PS-OCT. Furthermore, this study revealed there was a higher concentration of PGs in the outer sheath region than in the fascicles, and therefore the change in birefringence was reduced when extraction was performed on unsheathed tendons. The results provide new insights of tendon structure and the role of PGs on the structural stability of tendons, which also demonstrates the great potential for using PS-OCT as a diagnostic tool to examine tendon pathology.

  15. High-Temperature Optical Sensor

    Science.gov (United States)

    Adamovsky, Grigory; Juergens, Jeffrey R.; Varga, Donald J.; Floyd, Bertram M.

    2010-01-01

    A high-temperature optical sensor (see Figure 1) has been developed that can operate at temperatures up to 1,000 C. The sensor development process consists of two parts: packaging of a fiber Bragg grating into a housing that allows a more sturdy thermally stable device, and a technological process to which the device is subjected to in order to meet environmental requirements of several hundred C. This technology uses a newly discovered phenomenon of the formation of thermally stable secondary Bragg gratings in communication-grade fibers at high temperatures to construct robust, optical, high-temperature sensors. Testing and performance evaluation (see Figure 2) of packaged sensors demonstrated operability of the devices at 1,000 C for several hundred hours, and during numerous thermal cycling from 400 to 800 C with different heating rates. The technology significantly extends applicability of optical sensors to high-temperature environments including ground testing of engines, flight propulsion control, thermal protection monitoring of launch vehicles, etc. It may also find applications in such non-aerospace arenas as monitoring of nuclear reactors, furnaces, chemical processes, and other hightemperature environments where other measurement techniques are either unreliable, dangerous, undesirable, or unavailable.

  16. On the optimization of fiber Bragg grating optical sensor using genetic algorithm to monitor the strain of civil structure with high sensitivity

    Science.gov (United States)

    Kaur, Gurpreet; Kaler, Rajinder Singh; Kwatra, Naveen

    2016-08-01

    The effect of strain on civil structures is experimentally studied using fiber Bragg grating (FBG). The genetic algorithm is implemented to optimize the multiple parameters (Poisson's ratio, photoelastic coefficient P11, and photoelastic coefficient P12) of the proposed sensor. The optimized results helped in increasing the sensitivity in terms of wavelength shift. It is observed that the proposed FBG provides maximum wavelength shift of 38.16 nm with Poisson's ratio of 1.94, photoelastic coefficient P11 of 1.994, and photoelastic coefficient P12 of 1.8103.

  17. Phase Sensitive Amplification using Parametric Processes in Optical Fibers

    DEFF Research Database (Denmark)

    Kang, Ning

    , in specific, the design and optimization of such phase sensitive amplifiers (PSAs). For phase sensitive amplification in highly nonlinear fibers, optima points of operation have been identified for both the standard and the novel high stimulated Brillouin scattering (SBS) threshold highly nonlinear fiber....... Finally, preliminary simulations were carried out to investigate the inline amplification properties of such PSAs, and their pulse shaping capabilities....

  18. Cryogenic High-Sensitivity Magnetometer

    Science.gov (United States)

    Day, Peter; Chui, Talso; Goodstein, David

    2005-01-01

    A proposed magnetometer for use in a cryogenic environment would be sensitive enough to measure a magnetic-flux density as small as a picogauss (10(exp -16) Tesla). In contrast, a typical conventional flux-gate magnetometer cannot measure a magnetic-flux density smaller that about 1 microgauss (10(exp -10) Tesla). One version of this device, for operation near the low end of the cryogenic temperature range, would include a piece of a paramagnetic material on a platform, the temperature of which would be controlled with a periodic variation. The variation in temperature would be measured by use of a conventional germanium resistance thermometer. A superconducting coil would be wound around the paramagnetic material and coupled to a superconducting quantum interference device (SQUID) magnetometer.

  19. Passive endoscopic polarization sensitive optical coherence tomography with completely fiber based optical components

    Science.gov (United States)

    Cahill, Lucas; Lee, Anthony M. D.; Pahlevaninezhad, Hamid; Ng, Samson; MacAulay, Calum E.; Poh, Catherine; Lane, Pierre

    2015-03-01

    Polarization Sensitive Optical Coherence Tomography (PSOCT) is a functional extension of Optical Coherence Tomography (OCT) that is sensitive to well-structured, birefringent tissue such as scars, smooth muscle and cartilage. In this work, we present a novel completely fiber based swept source PSOCT system using a fiber-optic rotary pullback catheter. This PSOCT implementation uses only passive optical components and requires no calibration while adding minimal additional cost to a standard structural OCT imaging system. Due to its complete fiber construction, the system can be made compact and robust, while the fiber-optic catheter allows access to most endoscopic imaging sites. The 1.5mm diameter endoscopic probe can capture 100 frames per second at pullback speeds up to 15 mm/s allowing rapid traversal of large imaging fields. We validate the PSOCT system with known birefringent tissues and demonstrate in vivo PSOCT imaging of human oral scar tissue.

  20. Nano-textured high sensitivity ion sensitive field effect transistors

    Energy Technology Data Exchange (ETDEWEB)

    Hajmirzaheydarali, M.; Sadeghipari, M.; Akbari, M.; Shahsafi, A.; Mohajerzadeh, S., E-mail: mohajer@ut.ac.ir [Thin Film and Nanoelectronics Lab, Nanoelectronics Center of Excellence, School of Electrical and Computer Engineering, University of Tehran, Tehran 143957131 (Iran, Islamic Republic of)

    2016-02-07

    Nano-textured gate engineered ion sensitive field effect transistors (ISFETs), suitable for high sensitivity pH sensors, have been realized. Utilizing a mask-less deep reactive ion etching results in ultra-fine poly-Si features on the gate of ISFET devices where spacing of the order of 10 nm and less is achieved. Incorporation of these nano-sized features on the gate is responsible for high sensitivities up to 400 mV/pH in contrast to conventional planar structures. The fabrication process for this transistor is inexpensive, and it is fully compatible with standard complementary metal oxide semiconductor fabrication procedure. A theoretical modeling has also been presented to predict the extension of the diffuse layer into the electrolyte solution for highly featured structures and to correlate this extension with the high sensitivity of the device. The observed ultra-fine features by means of scanning electron microscopy and transmission electron microscopy tools corroborate the theoretical prediction.

  1. HIGH-EFFICIENCY AUTONOMOUS LASER ADAPTIVE OPTICS

    Energy Technology Data Exchange (ETDEWEB)

    Baranec, Christoph [Institute for Astronomy, University of Hawai' i at Mānoa, Hilo, HI, NZ 96720-2700 (United States); Riddle, Reed; Tendulkar, Shriharsh; Hogstrom, Kristina; Bui, Khanh; Dekany, Richard; Kulkarni, Shrinivas [Division of Physics, Mathematics, and Astronomy, California Institute of Technology, Pasadena, CA 91125 (United States); Law, Nicholas M. [Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3255 (United States); Ramaprakash, A. N.; Burse, Mahesh; Chordia, Pravin; Das, Hillol; Punnadi, Sujit, E-mail: baranec@hawaii.edu [Inter-University Centre for Astronomy and Astrophysics, Ganeshkhind, Pune 411007 (India)

    2014-07-20

    As new large-scale astronomical surveys greatly increase the number of objects targeted and discoveries made, the requirement for efficient follow-up observations is crucial. Adaptive optics imaging, which compensates for the image-blurring effects of Earth's turbulent atmosphere, is essential for these surveys, but the scarcity, complexity and high demand of current systems limit their availability for following up large numbers of targets. To address this need, we have engineered and implemented Robo-AO, a fully autonomous laser adaptive optics and imaging system that routinely images over 200 objects per night with an acuity 10 times sharper at visible wavelengths than typically possible from the ground. By greatly improving the angular resolution, sensitivity, and efficiency of 1-3 m class telescopes, we have eliminated a major obstacle in the follow-up of the discoveries from current and future large astronomical surveys.

  2. High-efficiency Autonomous Laser Adaptive Optics

    CERN Document Server

    Baranec, Christoph; Law, Nicholas M; Ramaprakash, A N; Tendulkar, Shriharsh; Hogstrom, Kristina; Bui, Khanh; Burse, Mahesh; Chordia, Pravin; Das, Hillol; Dekany, Richard; Kulkarni, Shrinivas; Punnadi, Sujit

    2014-01-01

    As new large-scale astronomical surveys greatly increase the number of objects targeted and discoveries made, the requirement for efficient follow-up observations is crucial. Adaptive optics imaging, which compensates for the image-blurring effects of Earth's turbulent atmosphere, is essential for these surveys, but the scarcity, complexity and high demand of current systems limits their availability for following up large numbers of targets. To address this need, we have engineered and implemented Robo-AO, a fully autonomous laser adaptive optics and imaging system that routinely images over 200 objects per night with an acuity 10 times sharper at visible wavelengths than typically possible from the ground. By greatly improving the angular resolution, sensitivity, and efficiency of 1-3 m class telescopes, we have eliminated a major obstacle in the follow-up of the discoveries from current and future large astronomical surveys.

  3. [A simple highly sensitive recording microspectrophotometer].

    Science.gov (United States)

    Govardovskiĭ, V I; Zueva, L V

    1988-04-01

    A design of the recording microspectrophotometer is described. The instrument possesses an absolutely flat base line and quantum-noise limited detection threshold. Two principal elements of the design are the "jumping" stage, and the logarithmic amplifier with the phase-sensitive detector which converts the photomultiplier output into the optical density signal. The performance of the instrument is illustrated by the recordings of visual pigment spectra in single photoreceptors.

  4. Laryngeal imaging with polarization-sensitive optical coherence tomography

    Science.gov (United States)

    Burns, James A.; Kim, Ki Hean; Anderson, R. Rox

    2011-03-01

    Objectives/Hypothesis: Optical coherence tomography (OCT), an imaging technology that provides crosssectional subsurface tissue structure images using backscattered light, is a promising noninvasive, imaging modality for in-vivo assessment of vocal fold layered microstructure. Polarization-sensitive OCT (PS-OCT) augments conventional OCT by detecting changes in the polarization state of reflected light. This study imaged various benign laryngeal pathologies in patients undergoing direct laryngoscopy under general anesthesia to determine whether PS-OCT would provide useful additional information about vocal fold microstructure and glottic surface pathology. Study Design:Prospective clinical trial. Methods: Eighteen patients who were undergoing microlaryngoscopy under general anesthesia for benign glottic disease were imaged bilaterally with OCT and PS-OCT (N=34 vocal folds). Intraoperative microphotography guided placement of the imaging probe. Normalappearing glottic tissue was also imaged if present. When clinically indicated, biopsy or complete removal of the lesion established histologic confirmation. Results: PS-OCT provided high quality, vertical, cross-sectional images up to 1.2mm deep that complemented microlaryngoscopy, and conventional OCT for vocal fold pathologies. Scar tissue was visualized by PS-OCT, characterized by a birefringence pattern more intense than that of normal glottic tissue. Conclusions: Combining PS-OCT with OCT during human vocal cord imaging provides useful information in characterizing vocal cord lesions, particularly scar tissue.

  5. Optical Near Field Studies of Plasmonic and Optical Antennas For Sensitive and Selective Biosensing Applications

    Science.gov (United States)

    Gelfand, Ryan M.

    For biosensing applications a useful device needs at least two properties: high sensitivity and high selectivity. Optical spectroscopy offers unique advantages over other sensing techniques however one big challenge to overcome is the mismatch between wavelength and the size of biologically relevant molecules. In order to have high enough sensitivity to approach the single-molecule limit, the interaction between the light and the molecule should be strong. However, the diffraction limit of light is approximately half the incidence wavelength, on the order of 100 nm for the smallest nondestructive wavelengths. This presents a significant mismatch between the size of the molecule and the smallest focus spot of the light. The photo-excitation should be compressed more than 100 fold to interact strongly. We must use metallic antennas that convert the incidence radiation into plasmonic modes which can then be compressed well below the wavelength diffraction limit. Studying the near field characteristics of these metallic nanostructures will help us gain insight into this emerging field and allow us to better use them in developing next generation devices. We have developed different geometries of these antennas and simulated their performance using Finite Difference Time Domain software. We have concentrated our efforts in the mid-infrared because that is the natural molecular vibration frequency region and also the near infrared because at these frequencies there exists a mature industry for compact sources, detectors, and fiber optic components. Our simulations show a 6,000 fold mode compression for a bowtie antenna and a million fold compression for a plasmonic photonic crystal (ppc) antenna. The bull's-eye antenna does not have as a high a mode compression but it has a natural geometry for molecular sensing due to the central metallic disc. Experimentally, we have measured the near field of these antennas with a custom back reflection apertureless NSOM setup in both

  6. Optics assembly for high power laser tools

    Science.gov (United States)

    Fraze, Jason D.; Faircloth, Brian O.; Zediker, Mark S.

    2016-06-07

    There is provided a high power laser rotational optical assembly for use with, or in high power laser tools for performing high power laser operations. In particular, the optical assembly finds applications in performing high power laser operations on, and in, remote and difficult to access locations. The optical assembly has rotational seals and bearing configurations to avoid contamination of the laser beam path and optics.

  7. Optics assembly for high power laser tools

    Energy Technology Data Exchange (ETDEWEB)

    Fraze, Jason D.; Faircloth, Brian O.; Zediker, Mark S.

    2016-06-07

    There is provided a high power laser rotational optical assembly for use with, or in high power laser tools for performing high power laser operations. In particular, the optical assembly finds applications in performing high power laser operations on, and in, remote and difficult to access locations. The optical assembly has rotational seals and bearing configurations to avoid contamination of the laser beam path and optics.

  8. Polarization-sensitive optical coherence tomography applied to intervertebral disk

    Science.gov (United States)

    Matcher, Stephen J.; Winlove, Peter; Gangnus, Sergei V.

    2003-07-01

    Polarization-sensitive optical coherence tomography (PSOCT) is a powerful new optical imaging modality that is sensitive to the birefringence properties of tissues. It thus has potential applications in studying the large-scale ordering of collagen fibers within connective tisues and changes related to pathology. As a tissue for study by PSOCT, intervertebral disk respresents an interesting system as the collagen organization is believed to show pronounced variations with depth, on a spatial scale of about 100 μm. We have used a polarization-sensitive optical coherence tomography system to measure the birefringence properties of bovine caudal intervertebral disk and compared this with equine flexor tendon. The result for equine tendon, δ = (3.0 +/- 0.5)x10-3 at 1.3 μm, is in broad agreement with values reported for bovine tendon, while bovine intervertebral disk displays a birefringence of about half this, δ = 1.2 x 10-3 at 1.3 μm. While tendon appears to show a uniform fast-axis over 0.8 mm depth, intervertebral disk shows image contrast at all orientations relative to a linearly polarized input beam, suggesting a variation in fast-axis orientation with depth. These initial results suggest that PSOCT could be a useful tool to study collagen organization within this tissue and its variation with applied load and disease.

  9. Experimental Investigation on a Highly Sensitive Atomic Magnetometer

    Institute of Scientific and Technical Information of China (English)

    LI Shu-Guang; XU Yun-Fei; WANG Zhao-Ying; LIU Yun-Xian; LIN Qiang

    2009-01-01

    A highly sensitive all-optical atomic magnetometer based on the magnetooptical effect which uses the advanced technique of single laser beam detection is reported and demonstrated experimentally.A sensitivityof 0.5 pT/Hz1/2 is obtained by analyzing the magnetic noise spectrum,which exceeds that of most traditional magnetometers.This kind of atomic magnetometer is very compact,has a low power consumption,and has a high theoretical sensitivity limit,which make it suitable for many applications.

  10. Optical Molecular Imaging Frontiers in Oncology: The Pursuit of Accuracy and Sensitivity

    Directory of Open Access Journals (Sweden)

    Kun Wang

    2015-09-01

    Full Text Available Cutting-edge technologies in optical molecular imaging have ushered in new frontiers in cancer research, clinical translation, and medical practice, as evidenced by recent advances in optical multimodality imaging, Cerenkov luminescence imaging (CLI, and optical image-guided surgeries. New abilities allow in vivo cancer imaging with sensitivity and accuracy that are unprecedented in conventional imaging approaches. The visualization of cellular and molecular behaviors and events within tumors in living subjects is improving our deeper understanding of tumors at a systems level. These advances are being rapidly used to acquire tumor-to-tumor molecular heterogeneity, both dynamically and quantitatively, as well as to achieve more effective therapeutic interventions with the assistance of real-time imaging. In the era of molecular imaging, optical technologies hold great promise to facilitate the development of highly sensitive cancer diagnoses as well as personalized patient treatment—one of the ultimate goals of precision medicine.

  11. Harmonic detection of magnetic resonance for sensitivity improvement of optical atomic magnetometers

    Science.gov (United States)

    Ranjbaran, M.; Tehranchi, M. M.; Hamidi, S. M.; Khalkhali, S. M. H.

    2017-02-01

    Highly sensitive atomic magnetometers use optically detected magnetic resonance of atomic spins to measure extremely weak magnetic field changes. The magnetometer sensitivity is directly proportional to the ratio of intensity to line-shape of the resonance signal. To obtain narrower resonance signal, we implemented harmonic detection of magnetic resonance method in Mx configuration. The nonlinear spin polarization dynamics in detection of the higher harmonics were employed in phenomenological Bloch equations. The measured and simulated harmonic components of the resonance signals in frequency domain yielded significantly narrower line-width accompanying much improved sensitivity. Our results confirm the sensitivity improvement by a factor of two in optical atomic magnetometer via second harmonic signal which can open a new insight in the weak magnetic field measurement system design.

  12. Optically transparent bionanofiber composites with low sensitivity to refractive index of the polymer matrix

    Science.gov (United States)

    Nogi, Masaya; Handa, Keishin; Nakagaito, Antonio Norio; Yano, Hiroyuki

    2005-12-01

    Transparent polymers were reinforced by bacterial cellulose (BC) nanofibers, which are 10×50nm ribbon-shaped fibers. They exhibited high luminous transmittance at a fiber content as high as 60 wt %, and low sensitivity to a variety of refractive indices of matrix resins. Due to the nanofiber size effect, high transparency was obtained against a wider distribution of refractive index of resins from 1.492 to 1.636 at 20 °C. The optical transparency was also surprisingly insensitive to temperature increases up to 80 °C. As such, BC nanofibers appear to be viable candidates for optically transparent reinforcement.

  13. Automated online optical biosensing system for continuous real-time determination of microcystin-LR with high sensitivity and specificity: early warning for cyanotoxin risk in drinking water sources.

    Science.gov (United States)

    Shi, Han-Chang; Song, Bao-Dong; Long, Feng; Zhou, Xiao-Hong; He, Miao; Lv, Qing; Yang, Hai-Yang

    2013-05-07

    The accelerated eutrophication of surface water sources and climate change have led to an annual occurrence of cyanobacterial blooms in many drinking water resources. To minimize the health risks to the public, cyanotoxin detection methods that are rapid, sensitive, real time, and high frequency must be established. In this study, an innovative automated online optical biosensing system (AOBS) was developed for the rapid detection and early warning of microcystin-LR (MC-LR), one of the most toxic cyanotoxins and most frequently detected in environmental water. In this system, the capturing molecular MC-LR-ovalbumin (MC-LR-OVA) was covalently immobilized onto a biochip surface. By an indirect competitive detection mode, samples containing different concentrations of MC-LR were premixed with a certain concentration of fluorescence-labeled anti-MC-LR-mAb, which binds to MC-LR with high specificity. Then, the sample mixture was pumped onto the biochip surface, and a higher concentration of MC-LR led to less fluorescence-labeled antibody bound onto the biochip surface and thus to lower fluorescence signal. The quantification of MC-LR ranges from 0.2 to 4 μg/L, with a detection limit determined as 0.09 μg/L. The high specificity and selectivity of the sensor were evaluated in terms of its response to a number of potentially interfering cyanotoxins. Potential interference of the environmental sample matrix was assessed by spiked samples, and the recovery of MC-LR ranged from 90 to 120% with relative standard deviation values online analysis that satisfies the high demand for ensuring the safety of drinking water sources. The AOBS can also serve as early warning system for accidental or intentional water pollution.

  14. Optical tractography of the mouse heart using polarization-sensitive optical coherence tomography.

    Science.gov (United States)

    Wang, Yuanbo; Yao, Gang

    2013-01-01

    We developed a method to image myocardial fiber architecture in the mouse heart using a Jones matrix-based polarization-sensitive optical coherence tomography (PSOCT) system. The "cross-helical" laminar structure of myocardial fibers can be clearly visualized using this technology. The obtained myocardial fiber organization agrees well with existing knowledge acquired using conventional histology and diffusion tensor magnetic resonance imaging.

  15. Polarization sensitive spectroscopic optical coherence tomography for multimodal imaging

    Science.gov (United States)

    Strąkowski, Marcin R.; Kraszewski, Maciej; Strąkowska, Paulina; Trojanowski, Michał

    2015-03-01

    Optical coherence tomography (OCT) is a non-invasive method for 3D and cross-sectional imaging of biological and non-biological objects. The OCT measurements are provided in non-contact and absolutely safe way for the tested sample. Nowadays, the OCT is widely applied in medical diagnosis especially in ophthalmology, as well as dermatology, oncology and many more. Despite of great progress in OCT measurements there are still a vast number of issues like tissue recognition or imaging contrast enhancement that have not been solved yet. Here we are going to present the polarization sensitive spectroscopic OCT system (PS-SOCT). The PS-SOCT combines the polarization sensitive analysis with time-frequency analysis. Unlike standard polarization sensitive OCT the PS-SOCT delivers spectral information about measured quantities e.g. tested object birefringence changes over the light spectra. This solution overcomes the limits of polarization sensitive analysis applied in standard PS-OCT. Based on spectral data obtained from PS-SOCT the exact value of birefringence can be calculated even for the objects that provide higher order of retardation. In this contribution the benefits of using the combination of time-frequency and polarization sensitive analysis are being expressed. Moreover, the PS-SOCT system features, as well as OCT measurement examples are presented.

  16. High-power optics lasers and applications

    CERN Document Server

    Apollonov, Victor V

    2015-01-01

    This book covers the basics, realization and materials for high power laser systems and high power radiation interaction with  matter. The physical and technical fundamentals of high intensity laser optics and adaptive optics and the related physical processes in high intensity laser systems are explained. A main question discussed is: What is power optics? In what way is it different from ordinary optics widely used in cameras, motion-picture projectors, i.e., for everyday use? An undesirable consequence of the thermal deformation of optical elements and surfaces was discovered during studies of the interaction with powerful incident laser radiation. The requirements to the fabrication, performance and quality of optical elements employed within systems for most practical applications are also covered. The high-power laser performance is generally governed by the following: (i) the absorption of incident optical radiation (governed primarily by various absorption mechanisms), (ii) followed by a temperature ...

  17. Sensitive Detection: Photoacoustics, Thermography, and Optical Radiation Pressure

    Energy Technology Data Exchange (ETDEWEB)

    Diebold, Gerald J. [Brown Univ., Providence, RI (United States)

    2017-04-21

    Research during the granting period has been carried out in several areas concerned with sensitive detection. An infrared pyrometer based on the photoacoustic effect has been developed. The sensitivity of this instrument to temperature differentials has been shown to be 50 mK. An investigation of transients that accompany photoacoustic waves generated by pulsed lasers has been carried out. Experiments have shown the existence of the transients, and a theory based on rapid heat diffusion has been developed. The photoacoustic effect in one dimension is known to increase without bound (in the linear acoustics regime) when an optical beam moves in a fluid at the sound speed. A solution to the wave equation for pressure has been found that describes the photoacoustic effect in a cell where an infrared optical grating moves at the sound speed. It was shown that the amplification effect exists along with a cavity resonance that can be used to great advantage in trace gas detection. The theory of the photoacoustic effect in a structure where the acoustic properties periodically vary in a one-dimensional based has been formulated based on solutions to a Mathieu equation. It was found that it is possible to excite photoacoustic waves within the band gaps to produce large amplitude acoustic waves. The idea of self-oscillation in a photoacoustic cell using a continuous laser has been investigated. A theory has been completed showing that in a compressive wave, the absorption increases as a result of the density increase leading to further absorption and hence an increased amplitude photoacoustic effect with the result that in a resonator, self-oscillation can place. Experiments have been carried out where irradiation of a suspension of absorbing carbon particles with a high power laser has been shown to result in cavitation luminescence. That is, following generation of CO and H2 from the carbon particles through the carbon-steam reaction, an expanding gas bubble is

  18. Temperature Sensitive Optical Phenomena in Heavy Metal Halide Films.

    Science.gov (United States)

    1979-01-08

    Heavy - metal halides such as Pb!2 and HgI2 exhibit a strongly tempera- ture dependent absorption edge at visible frequencies. The shift in the absorption...AOb9 537 ROCKWELL INTERNATIONAL ANAHEIM CA ELECTRONICS RESEAR—— ETC FIG L u G TEMPERATURE SENSITIVE OPTICAL PHENOMENA IN HEAVY METAL HALIDE F—— ETC (U...PHENOMENA IN HEAVY METAL HALIDE F — ET C( U) ,JAN 79 J D MC*LLEN, D M HEINZ. F S STEARNS DAAK7O— 77—C—01 6 5 UNCLASSIFIED C79 1501 _ _ U SB

  19. Primate retina imaging with polarization-sensitive optical coherence tomography

    Science.gov (United States)

    Ducros, Mathieu G.; Marsack, Jason D.; Rylander, H. Grady; Thomsen, Sharon L.; Milner, Thomas E.

    2001-12-01

    Polarization-sensitive optical coherence tomography (PSOCT) is applied to determine the depth-resolved polarization state of light backreflected from the eye. The birefringence of the retinal nerve fiber layer (RNFL) was observed and measured from PSOCT images recorded postmortem in a Rhesus monkey. An image-processing algorithm was developed to identify birefringent regions in acquired PSOCT retinal images and automatically determine the thickness of the RNFL. Values of the RNFL thickness determined from histology and PSOCT were compared. PSOCT may provide a new method to determine RNFL thickness and birefringence for glaucoma diagnostics.

  20. High sensitivity knitted fabric strain sensors

    Science.gov (United States)

    Xie, Juan; Long, Hairu; Miao, Menghe

    2016-10-01

    Wearable sensors are increasingly used in smart garments for detecting and transferring vital signals and body posture, movement and respiration. Existing fabric strain sensors made from metallized yarns have low sensitivity, poor comfort and low durability to washing. Here we report a knitted fabric strain sensor made from a cotton/stainless steel (SS) fibre blended yarn which shows much higher sensitivity than sensors knitted from metallized yarns. The fabric feels softer than pure cotton textiles owing to the ultrafine stainless steel fibres and does not lose its electrical property after washing. The reason for the high sensitivity of the cotton/SS knitted fabric sensor was explored by comparing its sensing mechanism with the knitted fabric sensor made from metallized yarns. The results show that the cotton/SS yarn-to-yarn contact resistance is highly sensitive to strain applied to hooked yarn loops.

  1. Improved optical performance monitoring technique based on nonlinear optics for high-speed WDM Nyquist systems

    Science.gov (United States)

    Guesmi, Latifa; Menif, Mourad

    2016-04-01

    The field of fiber optics nonlinearity is more discussed last years due to such remarkable enhancement in the nonlinear processes efficiency. In this paper, and for optical performance monitoring (OPM), a new achievement of nonlinear effects has been investigated. The use of cross-phase modulation (XPM) and four-wave mixing (FWM) effects between input optical signal and inserted continuous-wave probe has proposed for impairments monitoring. Indeed, transmitting a multi-channels phase modulated signal at high data rate (1 Tbps WDM Nyquist NRZ- DP-QPSK) improves the sensitivity and the dynamic range monitoring. It was observed by simulation results that various optical parameters including optical power, wavelength, chromatic dispersion (CD), polarization mode dispersion (PMD), optical signal-to-noise ratio (OSNR), Q-factor and so on, can be monitored. Also, the effect of increasing the channel spacing between WDM signals is studied and proved its use for FWM power monitoring.

  2. Near-surface sensitivity suppression way for diffuse reflective optical tomography: simulation and a phantom study

    Science.gov (United States)

    Fukuda, Keiko; Fujii, Mamiko

    2007-07-01

    Diffuse reflective optical measurement is a useful approach for monitoring the oxygen consumption of living tissue such as brain and muscle. To improve the oxygen consumption measurement accuracy, we propose a method for suppressing the near-surface sensitivity. Diffuse reflective light is detected at the aperture used for irradiating the light and is used as a cancellation signal for near-field sensitivity in the conventional measurement scheme. Photon fluence density functions and positional dependences of detected light sensitivity to change in absorbance were simulated. The sensitivity detected at the same position (aperture) as irradiation was significantly high for the near-surface region. With our method, the near-surface sensitivity is reduced by more than 90% while keeping target sensitivity almost constant (only 3% deterioration). The near-surface and deep-field sensitivity was measured with a phantom with light (785 nm) modulated at 1 kHz through an optical fiber bundle. It confirmed suppressed the near-surface sensitivity by subtracting the light detected at the same aperture from the light detected at another aperture.

  3. Optical sensitivity non-uniformity analysis and optimization of a tilt optical readout focal plane array

    Science.gov (United States)

    Fu, Jianyu; Shang, Haiping; Shi, Haitao; Li, Zhigang; Ou, Yi; Chen, Dapeng; Zhang, Qingchuan

    2016-02-01

    An optical readout focal plane array (FPA) usually has a differently tilted reflector/absorber at the initial state due to the micromachining technique. The angular deviation of the reflector/absorber has a strong impact on the optical sensitivity non-uniformity, which is a key factor which affects the imaging uniformity. In this study, a theoretical analysis has been developed, and it is found that the stress matching in SiO2-Aluminum (Al) bilayer leg could make a contribution towards reducing the optical sensitivity non-uniformity. Ion implantation of phosphorus (P) has been utilized to control the stress in SiO2 film. By controlling the implantation energy and dose, the stress and stress stability are modified. The optical readout FPA has been successfully fabricated with the stress-control technique based on P+ implantation. It is demonstrated that the gray response non-uniformity of optical readout FPA has decreased from 25.69% to 10.7%.

  4. Section on High Resolution Optical Imaging (HROI)

    Data.gov (United States)

    Federal Laboratory Consortium — The Section on High Resolution Optical Imaging (HROI) develops novel technologies for studying biological processes at unprecedented speed and resolution. Research...

  5. Development of an optical lens based alpha-particle imaging system using position sensitive photomultiplier tube

    Science.gov (United States)

    Ando, Koki; Oka, Miki; Yamamoto, Seiichi

    2017-02-01

    We developed an optical lens based alpha-particle imaging system using position sensitive photomultiplier tube (PSPMT). The alpha-particle imaging system consists of an optical lens, an extension tube and a 1 in. square high quantum efficiency (HQE) type PSPMT. After a ZnS(Ag) is attached to subject, the scintillation image of ZnS(Ag) is focused on the photocathode of the PSPMT by the use of the optical lens. With this configuration we could image the alpha particle distribution with energy information without contacting to the subject. The spatial resolution and energy resolution were 0.8 mm FWHM and 50% FWHM at 5 mm from the optical lens, respectively. We could successfully image the alpha particle distribution in uranium ore. The developed alpha-particle imaging system will be a new tool for imaging alpha emitters with energy information without contacting the subject.

  6. Reducing the phase sensitivity of laser-based optical reservoir computing systems.

    Science.gov (United States)

    Nguimdo, Romain Modeste; Verschaffelt, Guy; Danckaert, Jan; Van der Sande, Guy

    2016-01-25

    Optical implementations of reservoir computing systems are very promising because of their high processing speeds and the possibility to process several tasks in parallel. These systems can be implemented using semiconductor lasers subject to optical delayed feedback and optical injection. While the amount of the feedback/injection can be easily controlled, it is much more difficult to control the optical feedback/injection phase. We present extensive numerical investigations of the influence of the feedback/injection phases on laser-based reservoir computing systems with feedback. We show that a change in the phase can lead to a strong reduction in the reservoir computing system performance. We introduce a new readout layer design that -at least for some tasks- reduces this sensitivity to changes in the phase. It consists in optimizing the readout weights from a coherent combination of the reservoir's readout signal and its delayed version rather than only from the reservoir's readout signal as is usually done.

  7. Sensitivity and specificity of monochromatic photography of the ocular fundus in differentiating optic nerve head drusen and optic disc oedema: optic disc drusen and oedema.

    Science.gov (United States)

    Gili, Pablo; Flores-Rodríguez, Patricia; Yangüela, Julio; Orduña-Azcona, Javier; Martín-Ríos, María Dolores

    2013-03-01

    Evaluation of the efficacy of monochromatic photography of the ocular fundus in differentiating optic nerve head drusen (ONHD) and optic disc oedema (ODE). Sixty-six patients with ONHD, 31 patients with ODE and 70 healthy subjects were studied. Colour and monochromatic fundus photography with different filters (green, red and autofluorescence) were performed. The results were analysed blindly by two observers. The sensitivity, specificity and interobserver agreement (k) of each test were assessed. Colour photography offers 65.5 % sensitivity and 100 % specificity for the diagnosis of ONHD. Monochromatic photography improves sensitivity and specificity and provides similar results: green filter (71.20 % sensitivity, 96.70 % specificity), red filter (80.30 % sensitivity, 96.80 % specificity), and autofluorescence technique (87.8 % sensitivity, 100 % specificity). The interobserver agreement was good with all techniques used: autofluorescence (k = 0.957), green filter (k = 0.897), red filter (k = 0.818) and colour (k = 0.809). Monochromatic fundus photography permits ONHD and ODE to be differentiated, with good sensitivity and very high specificity. The best results were obtained with autofluorescence and red filter study.

  8. A highly sensitive fiber Bragg grating diaphragm pressure transducer

    Science.gov (United States)

    Allwood, Gary; Wild, Graham; Lubansky, Alex; Hinckley, Steven

    2015-10-01

    In this work, a novel diaphragm based pressure transducer with high sensitivity is described, including the physical design structure, in-depth analysis of optical response to changes in pressure, and a discussion of practical implementation and limitations. A flat circular rubber membrane bonded to a cylinder forms the body of the transducer. A fiber Bragg grating bonded to the center of the diaphragm structure enables the fractional change in pressure to be determined by analyzing the change in Bragg wavelength of the reflected spectra. Extensive evaluation of the physical properties and optical characteristics of the transducer has been performed through experimentation, and modeling using small deformation theory. The results show the transducer has a sensitivity of 0.116 nm/kPa, across a range of 15 kPa. Ultra-low cost interrogation of the optical signal was achieved through the use of an optically mismatched Bragg grating acting as an edge filter to convert the spectral change into an intensity change. A numerical model of the intensity based interrogation was implemented in order to validate the experimental results. Utilizing this interrogation technique and housing both the sensing and reference Bragg gratings within the main body of the transducer means it is effectively temperature insensitive and easily connected to electronic systems.

  9. Optical sensing in high voltage transmission lines using power over fiber and free space optics

    Science.gov (United States)

    Rosolem, João Batista; Bassan, Fabio Renato; Penze, Rivael Strobel; Leonardi, Ariovaldo Antonio; Fracarolli, João Paulo Vicentini; Floridia, Claudio

    2015-12-01

    In this work we propose the use of power over fiber (PoF) and free space optics (FSO) techniques to powering and receive signals from an electrical current sensor placed at high voltage potential using a pair of optical collimators. The technique evaluation was performed in a laboratorial prototype using 62.5/125 μm multimode fiber to study the sensitivity of the optical alignment and the influence of the collimation process in the sensing system wavelengths: data communication (1310 nm) and powering (830 nm). The collimators were installed in a rigid electric insulator in order to maintain the stability of transmission.

  10. Aluminum nanocantilevers for high sensitivity mass sensors

    DEFF Research Database (Denmark)

    Davis, Zachary James; Boisen, Anja

    2005-01-01

    We have fabricated Al nanocantilevers using a simple, one mask contact UV lithography technique with lateral and vertical dimensions under 500 and 100 nm, respectively. These devices are demonstrated as highly sensitive mass sensors by measuring their dynamic properties. Furthermore, it is shown ...

  11. Large temporal window contrast measurement using optical parametric amplification and low-sensitivity detectors

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Rahul C [Los Alamos National Laboratory; Johnson, Randall P [Los Alamos National Laboratory; Shimada, Tsutomu [Los Alamos National Laboratory; Hegelich, Bjorn M [Los Alamos National Laboratory

    2008-01-01

    To address few-shot pulse contrast measurement, we present a correlator coupling the high gain of an optical parametric amplification scheme with large pulse tilt. This combination enables a low sensitivity charge coupled device (CCD) to observe features in the pulse intensity within a 50 ps single-shot window with inter-window dynamic range > 10{sup 7} and < 0.5 mJ input energy. Partitioning of the single window with optical densities to boost the CCD dynamic range is considered.

  12. Multiphasic disseminated encephalomyelitis followed by optic neuritis in a child with gluten sensitivity.

    Science.gov (United States)

    Ching, B H; Mohamed, A R; Khoo, T B; Ismail, H I H M

    2015-08-01

    Multiphasic disseminated encephalomyelitis (MDEM) followed by optic neuritis (ON) has been described as a new entity in recent years. Gluten encephalopathy has also been recognized as a neurological manifestation of celiac disease. Accurate diagnosis of both is important due to the therapeutic implications. We report a girl presenting with recurrent encephalopathic polyfocal demyelinating episodes followed by optic neuritis, and a clinical history suggestive of gluten sensitivity. She had persistently high ESR, neutrophilia, and tested positive for anti-MOG (myelin oligodendrocyte glycoprotein) antibody. She responded well to methylprednisolone in each relapse, and achieved remission for a year after azathioprine was added.

  13. Highly sensitive optical sensor that detects Hg{sup 2+} and Cu{sup 2+} by immobilizing dicarboxylate 1,5-diphenyl-3-thiocarbazone on surface functionalized PVA microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xue, E-mail: baixue@hhu.edu.cn; Gu, Haixin; Hua, Zulin; Dai, Zhangyan; Yang, Bei; Li, Yulong

    2015-11-15

    Highlights: • PVA microspheres were chosen as carrier and DDT groups were chosen as chromophores. • The DDT–PVA microspheres could detect Hg{sup 2+} and Cu{sup 2+} simultaneously within 120 s. • The DDT–PVA microspheres had excellent detection for Hg{sup 2+} and Cu{sup 2+} ions. • The DDT–PVA microspheres had preeminent selectivity and reusability. - Abstract: A novel optical sensor to detect Hg{sup 2+} and Cu{sup 2+} is prepared by immobilizing a synthesized dicarboxylate 1,5-diphenyl-3-thiocarbazone (DDT) group on functionalized polyvinyl alcohol (PVA) microspheres. This optical sensor is successfully fabricated by extensive characterization with Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. Its colorimetric properties, selectivity, sensitivity, and reversibility are investigated as well. In this sensing system, DDT–PVA selectively recognized multiple heavy metal ions, as indicated by the changes in color from orange to scarlet for Hg{sup 2+} and from orange to gray for Cu{sup 2+}. In particular, this optical sensor exhibits the most apparent color changes at pH levels of 12 and 2. Hence, Hg{sup 2+} and Cu{sup 2+} can be detected in aqueous solution at minimum detection limits of 0.053 and 0.132 μM, respectively, with a UV-vis spectrometer. Furthermore, the sensor can be regenerated by ethylene diamine tetraacetic acid and reused several times. Therefore, the optical sensor can detect Hg{sup 2+} because of its selectivity, sensitivity, and reversibility.

  14. 25-Gbit/s burst-mode optical receiver using high-speed avalanche photodiode for 100-Gbit/s optical packet switching.

    Science.gov (United States)

    Nada, Masahiro; Nakamura, Makoto; Matsuzaki, Hideaki

    2014-01-13

    25-Gbit/s error-free operation of an optical receiver is successfully demonstrated against burst-mode optical input signals without preambles. The receiver, with a high-sensitivity avalanche photodiode and burst-mode transimpedance amplifier, exhibits sufficient receiver sensitivity and an extremely quick response suitable for burst-mode operation in 100-Gbit/s optical packet switching.

  15. Semiconductor optical amplifier-based all-optical gates for high-speed optical processing

    DEFF Research Database (Denmark)

    Stubkjær, Kristian

    2000-01-01

    Semiconductor optical amplifiers are useful building blocks for all-optical gates as wavelength converters and OTDM demultiplexers. The paper reviews the progress from simple gates using cross-gain modulation and four-wave mixing to the integrated interferometric gates using cross-phase modulation....... These gates are very efficient for high-speed signal processing and open up interesting new areas, such as all-optical regeneration and high-speed all-optical logic functions...

  16. All fiber optics circular-state swept source polarization-sensitive optical coherence tomography.

    Science.gov (United States)

    Lin, Hermann; Kao, Meng-Chun; Lai, Chih-Ming; Huang, Jyun-Cin; Kuo, Wen-Chuan

    2014-02-01

    A swept source (SS)-based circular-state (CS) polarization-sensitive optical coherence tomography (PS-OCT) constructed entirely with polarization-maintaining fiber optics components is proposed with the experimental verification. By means of the proposed calibration scheme, bulk quarter-wave plates can be replaced by fiber optics polarization controllers to, therefore, realize an all-fiber optics CS SSPS-OCT. We also present a numerical dispersion compensation method, which can not only enhance the axial resolution, but also improve the signal-to-noise ratio of the images. We demonstrate that this compact and portable CS SSPS-OCT system with an accuracy comparable to bulk optics systems requires less stringent lens alignment and can possibly serve as a technology to realize PS-OCT instrument for clinical applications (e.g., endoscopy). The largest deviations in the phase retardation (PR) and fast-axis (FA) angle due to sample probe in the linear scanning and a rotation angle smaller than 65 deg were of the same order as those in stationary probe setups. The influence of fiber bending on the measured PR and FA is also investigated. The largest deviations of the PR were 3.5 deg and the measured FA change by ~12 to 21 deg. Finally, in vivo imaging of the human fingertip and nail was successfully demonstrated with a linear scanning probe.

  17. High blood pressure and visual sensitivity

    Science.gov (United States)

    Eisner, Alvin; Samples, John R.

    2003-09-01

    The study had two main purposes: (1) to determine whether the foveal visual sensitivities of people treated for high blood pressure (vascular hypertension) differ from the sensitivities of people who have not been diagnosed with high blood pressure and (2) to understand how visual adaptation is related to standard measures of systemic cardiovascular function. Two groups of middle-aged subjects-hypertensive and normotensive-were examined with a series of test/background stimulus combinations. All subjects met rigorous inclusion criteria for excellent ocular health. Although the visual sensitivities of the two subject groups overlapped extensively, the age-related rate of sensitivity loss was, for some measures, greater for the hypertensive subjects, possibly because of adaptation differences between the two groups. Overall, the degree of steady-state sensitivity loss resulting from an increase of background illuminance (for 580-nm backgrounds) was slightly less for the hypertensive subjects. Among normotensive subjects, the ability of a bright (3.8-log-td), long-wavelength (640-nm) adapting background to selectively suppress the flicker response of long-wavelength-sensitive (LWS) cones was related inversely to the ratio of mean arterial blood pressure to heart rate. The degree of selective suppression was also related to heart rate alone, and there was evidence that short-term changes of cardiovascular response were important. The results suggest that (1) vascular hypertension, or possibly its treatment, subtly affects visual function even in the absence of eye disease and (2) changes in blood flow affect retinal light-adaptation processes involved in the selective suppression of the flicker response from LWS cones caused by bright, long-wavelength backgrounds.

  18. Highly Energetic, Low Sensitivity Aromatic Peroxy Acids.

    Science.gov (United States)

    Gamage, Nipuni-Dhanesha H; Stiasny, Benedikt; Stierstorfer, Jörg; Martin, Philip D; Klapötke, Thomas M; Winter, Charles H

    2016-02-18

    The synthesis, structure, and energetic materials properties of a series of aromatic peroxy acid compounds are described. Benzene-1,3,5-tris(carboperoxoic) acid is a highly sensitive primary energetic material, with impact and friction sensitivities similar to those of triacetone triperoxide. By contrast, benzene-1,4-bis(carboperoxoic) acid, 4-nitrobenzoperoxoic acid, and 3,5-dinitrobenzoperoxoic acid are much less sensitive, with impact and friction sensitivities close to those of the secondary energetic material 2,4,6-trinitrotoluene. Additionally, the calculated detonation velocities of 3,5-dinitrobenzoperoxoic acid and 2,4,6-trinitrobenzoperoxoic acid exceed that of 2,4,6-trinitrotoluene. The solid-state structure of 3,5-dinitrobenzoperoxoic acid contains intermolecular O-H⋅⋅⋅O hydrogen bonds and numerous N⋅⋅⋅O, C⋅⋅⋅O, and O⋅⋅⋅O close contacts. These attractive lattice interactions may account for the less sensitive nature of 3,5-dinitrobenzoperoxoic acid.

  19. High performance fiber-based optical coherent detection

    Science.gov (United States)

    Chen, Youming

    The sensitivity of signal detection is of major interest for optical high speed communication systems and LIght Detection And Ranging (lidar) systems. Sensitive receivers in fiber-optical networks can reduce transmitter power or amplifier amplification requirements and extend link spans. High receiver sensitivity allows links to be established over long distances in deep space satellite communication systems and large atmospheric attenuation to be overcome in terrestrial free space communications. For lidar systems, the sensitivity of signal detection determines how far and how accurately the lidar can detect the remote objects. Optical receivers employ either coherent or direct detection. In addition to amplitude, coherent detection extracts frequency and phase information from received signals, whereas direct detection extracts the received pulse amplitude only. In theory, coherent detection should yield the highest receiver sensitivity. Another possible technique to improve detection sensitivity is to employ a fiber preamplifier. This technique has been successfully demonstrated in direct detection systems but not in the coherent detection systems. Due to the existence of amplified spontaneous emission (ASE) inside the amplifier, the sensitivity of coherent detection varies with the data rate or pulse rate. For this reason, optically preamplified coherent detection is not used in applications as commonly as optically preamplified direct detection. We investigate the performance of coherent detection employing a fiber amplifier and time-domain-filter. The fiber amplifier is used as the optical preamplifier of the coherent detection system. To reduce the noise induced by the preamplifier to a maximum extent, we investigate the noise properties for both a single pass amplifier and a double pass amplifier. The relative intensity noise and linewidth broadening caused by ASE have been experimentally characterized. The results show that the double pass amplifier has

  20. Refractive index sensitivity enhancement of optical fiber cladding mode by depositing nanofilm via ALD technology.

    Science.gov (United States)

    Zhao, Ying; Pang, Fufei; Dong, Yanhua; Wen, Jianxiang; Chen, Zhenyi; Wang, Tingyun

    2013-11-04

    The atomic layer deposition (ALD) technology is introduced to enhance the sensitivity of optical fiber cladding mode to surrounding refractive index (SRI) variation. The highly uniform Al2O nanofilm was deposited around the double cladding fiber (DCF) which presents cladding mode resonant feature. With the high refractive index coating, the cladding mode resonant spectrum was tuned. And the sensitivity enhancement for SRI sensor was demonstrated. Through adjusting the deposition cycles, a maximum sensitivity of 723 nm/RIU was demonstrated in the DCF with 2500 deposition cycles at the SRI of 1.34. Based on the analysis of cladding modes reorganization, the cladding modes transition of the coated DCF was investigated theoretically. With the high performance nanofilm coating, the proposed SRI sensor is expected to have wide applications in chemical sensors and biosensors.

  1. Magneto-Optic Fiber Bragg Gratings with Application to High-Resolution Magnetic Field Sensors

    Institute of Scientific and Technical Information of China (English)

    Bao-Jian Wu; Ying Yang; Kun Qiu

    2008-01-01

    Magneto-optic fiber Bragg gratings (MFBG) based on magneto-optic materials have a lot of potential applications for sensing and optical signal processing. The transmission and reflection spectra of guided optical waves in the MFBG are investigated. According to the sensitivity of MFBG spectral lines to the magneto-optic coupling intensity varying with applied magnetic field, a novel magnetic field sensor of high-resolution up to 0.01 nm/(kA/m) is predicted.

  2. An optical fan for light beams for high-precision optical measurements and optical switching

    CERN Document Server

    Zhou, Zhi-Yuan; Ding, Dong-Sheng; Jiang, Yun-Kun; Zhang, Wei; Shi, Shuai; Shi, Bao-Sen; Guo, Guang-Can

    2014-01-01

    The polarization and orbital angular momentum properties of light are of great importance in optical science and technology in the fields of high precision optical measurements and high capacity and high speed optical communications. Here we show, a totally new method, based on a combination of these two properties and using the thermal dispersion and electro-optical effect of birefringent crystals, the construction of a simple and robust scheme to rotate a light beam like a fan. Using a computer-based digital image processing technique, we determine the temperature and the thermal dispersion difference of the crystal with high resolution. We also use the rotation phenomenon to realize thermo-optic and electro-optic switches. The basic operating principles for measurement and switching processes are presented in detail. The methods developed here will have wide practical applicability in various fields, including remote sensing, materials science and optical communication networks.

  3. Highly sensitive catalytic spectrophotometric determination of ruthenium

    Science.gov (United States)

    Naik, Radhey M.; Srivastava, Abhishek; Prasad, Surendra

    2008-01-01

    A new and highly sensitive catalytic kinetic method (CKM) for the determination of ruthenium(III) has been established based on its catalytic effect on the oxidation of L-phenylalanine ( L-Pheala) by KMnO 4 in highly alkaline medium. The reaction has been followed spectrophotometrically by measuring the decrease in the absorbance at 526 nm. The proposed CKM is based on the fixed time procedure under optimum reaction conditions. It relies on the linear relationship where the change in the absorbance (Δ At) versus added Ru(III) amounts in the range of 0.101-2.526 ng ml -1 is plotted. Under the optimum conditions, the sensitivity of the proposed method, i.e. the limit of detection corresponding to 5 min is 0.08 ng ml -1, and decreases with increased time of analysis. The method is featured with good accuracy and reproducibility for ruthenium(III) determination. The ruthenium(III) has also been determined in presence of several interfering and non-interfering cations, anions and polyaminocarboxylates. No foreign ions interfered in the determination ruthenium(III) up to 20-fold higher concentration of foreign ions. In addition to standard solutions analysis, this method was successfully applied for the quantitative determination of ruthenium(III) in drinking water samples. The method is highly sensitive, selective and very stable. A review of recently published catalytic spectrophotometric methods for the determination of ruthenium(III) has also been presented for comparison.

  4. Optic axis determination by fibre-based polarization-sensitive swept-source optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lu Zenghai; Kasaragod, Deepa K; Matcher, Stephen J, E-mail: z.lu@sheffield.ac.uk, E-mail: s.j.matcher@sheffield.ac.uk [Department of Materials Science and Engineering, Kroto Research Institute, University of Sheffield, North Campus, Broad Lane, Sheffield, S3 7HQ (United Kingdom)

    2011-02-21

    We describe a fibre-based variable-incidence angle (VIA) polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) system to determine the 3D optical axis of birefringent biological tissues. Single-plane VIA-PS-OCT is also explored which requires measurement of the absolute fast-axis orientation. A state-of-the-art PS-SS-OCT system with some improvements both in hardware and software was used to determine the apparent optical birefringence of equine tendon for a number of different illumination directions. Polar and azimuthal angles of cut equine tendon were produced by the VIA method and compared with the nominal values. A quarter waveplate (QWP) and equine tendon were used as test targets to validate the fast-axis measurements using the system. Polar and azimuthal angles of cut equine tendon broadly agreed with the expected values within about 8% of the nominal values. A theoretical and experimental analysis of the effect of the sample arm fibre on determination of optical axis orientation using a proposed definition based on the orientation of the eigenpolarization ellipse experimentally confirms that this algorithm only works correctly for special settings of the sample arm fibre. A proposed algorithm based on the angle between Stokes vectors on the Poincare sphere is confirmed to work for all settings of the sample arm fibre. A calibration procedure is proposed to remove the sign ambiguity of the measured orientation and was confirmed experimentally by using the QWP.

  5. Enhanced laboratory sensitivity to variation of the fine-structure constant using highly charged ions.

    Science.gov (United States)

    Berengut, J C; Dzuba, V A; Flambaum, V V

    2010-09-17

    We study atomic systems that are in the frequency range of optical atomic clocks and have enhanced sensitivity to potential time variation of the fine-structure constant α. The high sensitivity is due to coherent contributions from three factors: high nuclear charge Z, high ionization degree, and significant differences in the configuration composition of the states involved. Configuration crossing keeps the frequencies in the optical range despite the large ionization energies. We discuss a few promising examples that have the largest α sensitivities seen in atomic systems.

  6. High-sensitive cardiac troponin T

    Institute of Scientific and Technical Information of China (English)

    Ru-Yi Xu; Xiao-Fa Zhu; Ye Yang; Ping Ye

    2013-01-01

    Cardiac troponin is the preferred biomarker for the diagnosis of acute myocardial infarction (AMI). The recent development of a high-sensitive cardiac troponin T (hs-cTnT) assay permits detection of very low levels of cTnT. Using the hs-cTnT assay improves the overall diagnostic accuracy in patients with suspected AMI, while a negative result also has a high negative predictive value. The gain in sensitivity may be particularly important in patients with a short duration from symptom onset to admission. Measurement of cardiac troponin T with the hs-cTnT assay may provide strong prognostic information in patients with acute coronary syndromes, stable coronary artery disease, heart failure and even in the general population; however, increased sensitivity comes at a cost of decreased specificity. Serial testing, as well as clinical context and co-existing diseases, are likely to become increasingly important for the interpretation of hs-cTnT assay results.

  7. Sensitivity and Specificity of Cardiac Tissue Discrimination Using Fiber-Optics Confocal Microscopy.

    Science.gov (United States)

    Huang, Chao; Sachse, Frank B; Hitchcock, Robert W; Kaza, Aditya K

    2016-01-01

    Disturbances of the cardiac conduction system constitute a major risk after surgical repair of complex cases of congenital heart disease. Intraoperative identification of the conduction system may reduce the incidence of these disturbances. We previously developed an approach to identify cardiac tissue types using fiber-optics confocal microscopy and extracellular fluorophores. Here, we applied this approach to investigate sensitivity and specificity of human and automated classification in discriminating images of atrial working myocardium and specialized tissue of the conduction system. Two-dimensional image sequences from atrial working myocardium and nodal tissue of isolated perfused rodent hearts were acquired using a fiber-optics confocal microscope (Leica FCM1000). We compared two methods for local application of extracellular fluorophores: topical via pipette and with a dye carrier. Eight blinded examiners evaluated 162 randomly selected images of atrial working myocardium (n = 81) and nodal tissue (n = 81). In addition, we evaluated the images using automated classification. Blinded examiners achieved a sensitivity and specificity of 99.2 ± 0.3% and 98.0 ± 0.7%, respectively, with the dye carrier method of dye application. Sensitivity and specificity was similar for dye application via a pipette (99.2 ± 0.3% and 94.0 ± 2.4%, respectively). Sensitivity and specificity for automated methods of tissue discrimination were similarly high. Human and automated classification achieved high sensitivity and specificity in discriminating atrial working myocardium and nodal tissue. We suggest that our findings facilitate clinical translation of fiber-optics confocal microscopy as an intraoperative imaging modality to reduce the incidence of conduction disturbances during surgical correction of congenital heart disease.

  8. Sensitivity and Specificity of Cardiac Tissue Discrimination Using Fiber-Optics Confocal Microscopy

    Science.gov (United States)

    Huang, Chao; Sachse, Frank B.; Hitchcock, Robert W.; Kaza, Aditya K.

    2016-01-01

    Disturbances of the cardiac conduction system constitute a major risk after surgical repair of complex cases of congenital heart disease. Intraoperative identification of the conduction system may reduce the incidence of these disturbances. We previously developed an approach to identify cardiac tissue types using fiber-optics confocal microscopy and extracellular fluorophores. Here, we applied this approach to investigate sensitivity and specificity of human and automated classification in discriminating images of atrial working myocardium and specialized tissue of the conduction system. Two-dimensional image sequences from atrial working myocardium and nodal tissue of isolated perfused rodent hearts were acquired using a fiber-optics confocal microscope (Leica FCM1000). We compared two methods for local application of extracellular fluorophores: topical via pipette and with a dye carrier. Eight blinded examiners evaluated 162 randomly selected images of atrial working myocardium (n = 81) and nodal tissue (n = 81). In addition, we evaluated the images using automated classification. Blinded examiners achieved a sensitivity and specificity of 99.2±0.3% and 98.0±0.7%, respectively, with the dye carrier method of dye application. Sensitivity and specificity was similar for dye application via a pipette (99.2±0.3% and 94.0±2.4%, respectively). Sensitivity and specificity for automated methods of tissue discrimination were similarly high. Human and automated classification achieved high sensitivity and specificity in discriminating atrial working myocardium and nodal tissue. We suggest that our findings facilitate clinical translation of fiber-optics confocal microscopy as an intraoperative imaging modality to reduce the incidence of conduction disturbances during surgical correction of congenital heart disease. PMID:26808149

  9. Sensitivity and Specificity of Cardiac Tissue Discrimination Using Fiber-Optics Confocal Microscopy.

    Directory of Open Access Journals (Sweden)

    Chao Huang

    Full Text Available Disturbances of the cardiac conduction system constitute a major risk after surgical repair of complex cases of congenital heart disease. Intraoperative identification of the conduction system may reduce the incidence of these disturbances. We previously developed an approach to identify cardiac tissue types using fiber-optics confocal microscopy and extracellular fluorophores. Here, we applied this approach to investigate sensitivity and specificity of human and automated classification in discriminating images of atrial working myocardium and specialized tissue of the conduction system. Two-dimensional image sequences from atrial working myocardium and nodal tissue of isolated perfused rodent hearts were acquired using a fiber-optics confocal microscope (Leica FCM1000. We compared two methods for local application of extracellular fluorophores: topical via pipette and with a dye carrier. Eight blinded examiners evaluated 162 randomly selected images of atrial working myocardium (n = 81 and nodal tissue (n = 81. In addition, we evaluated the images using automated classification. Blinded examiners achieved a sensitivity and specificity of 99.2 ± 0.3% and 98.0 ± 0.7%, respectively, with the dye carrier method of dye application. Sensitivity and specificity was similar for dye application via a pipette (99.2 ± 0.3% and 94.0 ± 2.4%, respectively. Sensitivity and specificity for automated methods of tissue discrimination were similarly high. Human and automated classification achieved high sensitivity and specificity in discriminating atrial working myocardium and nodal tissue. We suggest that our findings facilitate clinical translation of fiber-optics confocal microscopy as an intraoperative imaging modality to reduce the incidence of conduction disturbances during surgical correction of congenital heart disease.

  10. Fiber Optic Component Tests In High Speed Data Bus Applications

    Science.gov (United States)

    Creswell, R.; Drake, M. D.; Husbands, C. R.

    1982-12-01

    A series of tests was performed to evaluate off-the-shelf components for the design of a fiber optic channel for the Nascom System Improvements Project in support of the NASA Goddard Space Flight Center. This paper describes the results of this series of tests, establishing operational performance of active and passive fiber optic components at data rates up to 150 Mb/s. These tests determine the transmission characteristics of the fiber optic transmitters and receivers and the effects of data rate, bit pattern sensitivity, and vestigial optical energy on the performance of these devices. Tests were also performed to evaluate the capability of fused biconical couplers to Function properly at these high data rates.

  11. Influence of PDMS encapsulation on the sensitivity and frequency range of fiber-optic interferometer

    Science.gov (United States)

    Nedoma, Jan; Fajkus, Marcel; Vasinek, Vladimir

    2016-10-01

    Fiber-optic sensors are one of the dynamically developing areas of photonics and photonic applications. This group of sensors can also include fiber-optic interferometers which enable very sensitive sensing. They are entirely passive regarding power supply, and immune to electromagnetic interference. This type of sensor is dependent on the phase change. It mostly used in the field which requires high measurement accuracy. We can achieve a change of sensitivity in the order of 10-8. The fundamental problem of fiber-optic interferometry is a design and imposition (encapsulation) of the measuring arm and reference arm of the interferometer. Polydimethylsiloxane elastomer (PDMS) is one of the possibilities to encapsulation of the sensory arm. Two-component PDMS Sylgard 184 is used type. The article analyzes the effect of encapsulation into a PDMS of the measuring arm of the interferometer to frequency response and sensitivity of the Mach-Zehnder interferometer with the division of power in a ratio of 1:1 (measuring arm and reference arm). Input power set to a reference value of 1 mW, this value was constant for all performed experimental measurements. The generator of a harmonic signal with fixed amplitude signal used for analysis of the frequency characteristic of the interferometer. The application written in LabView development environment, evaluated the amplitude-frequency spectra of the signal. Repeated test of assembled prototype verified the measured results.

  12. Photodetector having high speed and sensitivity

    Science.gov (United States)

    Morse, Jeffrey D.; Mariella, Jr., Raymond P.

    1991-01-01

    The present invention provides a photodetector having an advantageous combination of sensitivity and speed; it has a high sensitivity while retaining high speed. In a preferred embodiment, visible light is detected, but in some embodiments, x-rays can be detected, and in other embodiments infrared can be detected. The present invention comprises a photodetector having an active layer, and a recombination layer. The active layer has a surface exposed to light to be detected, and comprises a semiconductor, having a bandgap graded so that carriers formed due to interaction of the active layer with the incident radiation tend to be swept away from the exposed surface. The graded semiconductor material in the active layer preferably comprises Al.sub.1-x Ga.sub.x As. An additional sub-layer of graded In.sub.1-y Ga.sub.y As may be included between the Al.sub.1-x Ga.sub.x As layer and the recombination layer. The recombination layer comprises a semiconductor material having a short recombination time such as a defective GaAs layer grown in a low temperature process. The recombination layer is positioned adjacent to the active layer so that carriers from the active layer tend to be swept into the recombination layer. In an embodiment, the photodetector may comprise one or more additional layers stacked below the active and recombination layers. These additional layers may include another active layer and another recombination layer to absorb radiation not absorbed while passing through the first layers. A photodetector having a stacked configuration may have enhanced sensitivity and responsiveness at selected wavelengths such as infrared.

  13. High sensitivity troponin and valvular heart disease.

    Science.gov (United States)

    McCarthy, Cian P; Donnellan, Eoin; Phelan, Dermot; Griffin, Brian P; Sarano, Maurice Enriquez-; McEvoy, John W

    2017-01-16

    Blood-based biomarkers have been extensively studied in a range of cardiovascular diseases and have established utility in routine clinical care, most notably in the diagnosis of acute coronary syndrome (e.g., troponin) and the management of heart failure (e.g., brain-natriuretic peptide). The role of biomarkers is less well established in the management of valvular heart disease (VHD), in which the optimal timing of surgical intervention is often challenging. One promising biomarker that has been the subject of a number of recent VHD research studies is high sensitivity troponin (hs-cTn). Novel high-sensitivity assays can detect subclinical myocardial damage in asymptomatic individuals. Thus, hs-cTn may have utility in the assessment of asymptomatic patients with severe VHD who do not have a clear traditional indication for surgical intervention. In this state-of-the-art review, we examine the current evidence for hs-cTn as a potential biomarker in the most commonly encountered VHD conditions, aortic stenosis and mitral regurgitation. This review provides a synopsis of early evidence indicating that hs-cTn has promise as a biomarker in VHD. However, the impact of its measurement on clinical practice and VHD outcomes needs to be further assessed in prospective studies before routine clinical use becomes a reality.

  14. Ultrathin plasmonic nanogratings for rapid and highly-sensitive detection

    CERN Document Server

    Zeng, Beibei; Bartoli, Filbert J

    2014-01-01

    We developed a nanoplasmonic sensor platform employing the extraordinary optical properties of one-dimensional nanogratings patterned on 30nm-thick ultrathin Ag films. Excitation of Fano resonances in the ultrathin Ag nanogratings results in transmission spectra with high amplitude, large contrast, and narrow bandwidth, making them well-suited for rapid and highly-sensitive sensing applications. The ultrathin nanoplasmonic sensor chip was integrated with a polydimethylsiloxane (PDMS) microfluidic channel, and the measured refractive index resolution was found to be 1.46x10-6 refractive index units (RIU) with a high temporal resolution of 1 sec. This compares favorably with commercial prism-based surface plasmon resonance sensors, but is achieved using a more convenient collinear transmission geometry and a significantly smaller sensor footprint of 50x50um2. In addition, an order-of-magnitude improvement in the temporal and spatial resolutions was achieved relative to state-of-the-art nanoplasmonic sensors, fo...

  15. Angular and spectral sensitivity of fly photoreceptors. I. Integrated facet lens and rhabdomere optics

    NARCIS (Netherlands)

    Stavenga, D.G.

    2003-01-01

    Three optical components of a fly’s eye determine the angular sensitivity of the photoreceptors: the light diffracting facet lens, the wave-guiding rhabdomere and the light-absorbing visual pigment in the rhabdomere. How the integrated optical system of the fly eye shapes the angular sensitivity cur

  16. Birefringence measurement in polarization-sensitive optical coherence tomography using differential-envelope detection method

    Science.gov (United States)

    Kuo, Wen-Chuan; Lin, Shey-Chien; Chuang, Chung-Yu

    2010-05-01

    In this research, we integrated two demodulating logarithmic amplifiers with one differential amplifier for use in a Mach-Zehnder interferometer so as to obtain a two-channel polarization-sensitive optical coherence tomography system. Birefringence signals can be acquired using this system along with a differential-envelope detection method. Because the two orthogonal polarizations are common-path propagation, common noise originating from background fluctuations or multiple scattering in turbid media can be reduced to improve the detection sensitivity and accuracy of birefringence measurement. Besides, this simple and effective technique is an analog detection method and is capable of providing high temporal response; it can also help obtain a high time-bandwidth product as compared to the conventional method of using a numerical method with a limited sampling rate. The feasibility of the proposed system is supported by theory and is also shown by performing experiments involving a human vessel, which is a highly scattering medium with weak birefringence.

  17. High sensitivity moiré interferometry with compact achromatic interferometry

    Science.gov (United States)

    Czarnek, Robert

    Experimental observations and measurements are the sources of information essential for correct development of mathematical models of real structural materials. Moiré interferometry offers high sensitivity in full-field measurements of in-plane displacements on the surface of a specimen. Although it is a powerful method in experimental stress analysis, it has some shortcomings. One is that existing systems require highly coherent light. The only sufficient source of light for this application is a long cavity laser, which is relatively expensive and at best cumbersome. Another shortcoming is that measurements must be performed in a vibration-free environment, such as that found on a holographic table. These requirements limit the use of existing moiré interferometers to a holographic laboratory. In this paper a modified concept of compensation is presented, which permits the use of a chromatic source of light in a compact moiré system. The compensator provides order in the angles of incident light for each separate wavelength, so that the virtual reference grating created by each wavelength in a continuous spectrum is identical in frequency and spatial position. The result is a virtual reference grating that behaves exactly like that created in coherent light. With this development the use of a laser diode, which is a non-coherent light source of tiny dimensions, becomes practical. The special configuration of the optics that create the virtual grating allows its synchronization with the specimen grating and leads to an interferometer design that is relatively insensitive to the vibrations found in a mechanical testing laboratory. Sensitivity to relative motion is analyzed theoretically. This development provides the oppurtunity to apply moiré interferometry to solid mechanics problems that cannot be studied in an optics laboratory. Experimental verification of the optical concepts is provided. A compact moiré interferometer based on the presented idea was

  18. High Spectral Density Optical Communication Technologies

    CERN Document Server

    Nakazawa, Masataka; Miyazaki, Tetsuya

    2010-01-01

    The latest hot topics of high-spectral density optical communication systems using digital coherent optical fibre communication technologies are covered by this book. History and meaning of a "renaissance" of the technology, requirements to the Peta-bit/s class "new generation network" are also covered in the first part of this book. The main topics treated are electronic and optical devices, digital signal processing including forward error correction, modulation formats as well as transmission and application systems. The book serves as a reference to researchers and engineers.

  19. Jones matrix analysis for a polarization-sensitive optical coherence tomography system using fiber-optic components

    OpenAIRE

    Park, B. H.; Pierce, M. C.; Cense, B.; De Boer, MR

    2004-01-01

    We present an analysis for polarization-sensitive optical coherence tomography that facilitates the unrestricted use of fiber and fiber-optic components throughout an interferometer and yields sample birefringence, diattenuation, and relative optic axis orientation. We use a novel Jones matrix approach that compares the polarization states of light reflected from the sample surface with those reflected from within a biological sample for pairs of depth scans. The incident polarization alterna...

  20. Large pi-aromatic molecules as potential sensitizers for highly efficient dye-sensitized solar cells.

    Science.gov (United States)

    Imahori, Hiroshi; Umeyama, Tomokazu; Ito, Seigo

    2009-11-17

    Recently, dye-sensitized solar cells have attracted much attention relevant to global environmental issues. Thus far, ruthenium(II) bipyridyl complexes have proven to be the most efficient TiO(2) sensitizers in dye-sensitized solar cells. However, a gradual increment in the highest power conversion efficiency has been recognized in the past decade. More importantly, considering that ruthenium is a rare metal, novel dyes without metal or using inexpensive metal are desirable for highly efficient dye-sensitized solar cells. Large pi-aromatic molecules, such as porphyrins, phthalocyanines, and perylenes, are important classes of potential sensitizers for highly efficient dye-sensitized solar cells, owing to their photostability and high light-harvesting capabilities that can allow applications in thinner, low-cost dye-sensitized solar cells. Porphyrins possess an intense Soret band at 400 nm and moderate Q bands at 600 nm. Nevertheless, the poor light-harvesting properties relative to the ruthenium complexes have limited the cell performance of porphyrin-sensitized TiO(2) cells. Elongation of the pi conjugation and loss of symmetry in porphyrins cause broadening and a red shift of the absorption bands together with an increasing intensity of the Q bands relative to that of the Soret band. On the basis of the strategy, the cell performance of porphyrin-sensitized solar cells has been improved intensively by the enhanced light absorption. Actually, some push-pull-type porphyrins have disclosed a remarkably high power conversion efficiency (6-7%) that was close to that of the ruthenium complexes. Phthalocyanines exhibit strong absorption around 300 and 700 nm and redox features that are similar to porphyrins. Moreover, phthalocyanines are transparent over a large region of the visible spectrum, thereby enabling the possibility of using them as "photovoltaic windows". However, the cell performance was poor, owing to strong aggregation and lack of directionality in the

  1. Integrated optical investigation of two light-sensitive proteins

    Science.gov (United States)

    Fábián, László; Krekic, Szilvia; Tóth-Boconádi, Rudolf; Taneva, Stefka G.; Bálint, Agneta M.; Nánai, László; Dér, András

    2017-01-01

    Integrated optics is one of the most intensively investigated fields when working on alternative methods to overcome the disadvantages of integrated electronics. Besides inorganic active optical crystals, dyes and polymers, molecules of biological origin with suitable nonlinear optical properties can also find applications in integrated optical - biophotonic - devices. The state-of-the-art photonic integration technology is ready to provide the passive elements of integrated optical circuits. The bottle-neck in integrated optics is to find a proper nonlinear optical material that is supposed to be the cladding medium in waveguide-based photonic applications, performing light-controlled active functions. Based on our earlier results, here we present the experimental demonstration of subpicosecond photonic switching with an alternative approach, where the active role is performed by a biological material, the chromoprotein bacteriorhodopsin. Moreover, measurements of the light-induced refractive index change performed on a dried film of the Photoactive Yellow Protein are also presented. Our findings show that these photochromic pigments can be promising candidates as active nonlinear optical materials for all-optical data processing in future biophotonic applications. These results may serve as a basis for the future realization of protein-based integrated optical devices that can eventually lead to a conceptual revolution in the development of telecommunication technologies.

  2. Optics of high-performance electron microscopes*

    OpenAIRE

    H H Rose

    2016-01-01

    During recent years, the theory of charged particle optics together with advances in fabrication tolerances and experimental techniques has lead to very significant advances in high-performance electron microscopes. Here, we will describe which theoretical tools, inventions and designs have driven this development. We cover the basic theory of higher-order electron optics and of image formation in electron microscopes. This leads to a description of different methods to correct aberrations by...

  3. High-speed signal processing using highly nonlinear optical fibres

    DEFF Research Database (Denmark)

    Peucheret, Christophe; Oxenløwe, Leif Katsuo; Mulvad, Hans Christian Hansen

    2009-01-01

    relying on the phase of the optical field. Topics covered include all-optical switching of 640 Gbit/s and 1.28 Tbit/s serial data, wavelength conversion at 640 Gbit/s, optical amplitude regeneration of differential phase shift keying (DPSK) signals, as well as midspan spectral inversion for differential 8......We review recent progress in all-optical signal processing techniques making use of conventional silica-based highly nonlinear fibres. In particular, we focus on recent demonstrations of ultra-fast processing at 640 Gbit/s and above, as well as on signal processing of novel modulation formats...

  4. Heterogeneous catalysis in highly sensitive microreactors

    DEFF Research Database (Denmark)

    Olsen, Jakob Lind

    This thesis present a highly sensitive silicon microreactor and examples of its use in studying catalysis. The experimental setup built for gas handling and temperature control for the microreactor is described. The implementation of LabVIEW interfacing for all the experimental parts makes...... automated experiments and data collection possible. An argon ush at the O-rings (used to interface the silicon microreactor with the gas system), which was developed, is presented. It enables experiments with temperatures up to 400., and up to 500. for short periods of time. The CO oxidation reaction...... of adsorbates readily converted to methanol as the source of the transient increase in methanol production, is eliminated. A study of mass selected ruthenium nanoparticles from a magnetron-sputter gas-aggregation source, deposited in microreactors, is presented. It is, shown that CO methanation can be measured...

  5. High sensitive radiation detector for radiology dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Valente, M.; Malano, F. [Instituto de Fisica Enrique Gaviola, Oficina 102 FaMAF - UNC, Av. Luis Medina Allende, Ciudad Universitaria, 5000 Cordoba (Argentina); Molina, W.; Vedelago, J., E-mail: valente@famac.unc.edu.ar [Laboratorio de Investigaciones e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Laboratorio 448 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina)

    2014-08-15

    Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, dose rate recorded and incident direction independence as well as linear dose response. This work presents the development and characterization of a novel Fricke gel system, based on modified chemical compositions making possible its application in clinical radiology. Properties of standard Fricke gel dosimeter for high dose levels are used as starting point and suitable chemical modifications are introduced and carefully investigated in order to attain high resolution for low dose ranges, like those corresponding to radiology interventions. The developed Fricke gel radiation dosimeter system achieves the expected typical dose dependency, actually showing linear response in the dose range from 20 up to 4000 mGy. Systematic investigations including several chemical compositions are carried out in order to obtain a good enough dosimeter response for low dose levels. A suitable composition among those studied is selected as a good candidate for low dose level radiation dosimetry consisting on a modified Fricke solution fixed to a gel matrix containing benzoic acid along with sulfuric acid, ferrous sulfate, xylenol orange and ultra-pure reactive grade water. Dosimeter samples are prepared in standard vials for its in phantom irradiation and further characterization by spectrophotometry measuring visible light transmission and absorbance before and after irradiation. Samples are irradiated by typical kV X-ray tubes and calibrated Farmer type ionization chamber is used as reference to measure dose rates inside phantoms in at vials locations. Once sensitive material composition is already optimized, dose-response curves show significant improvement regarding overall sensitivity for low dose levels. According to

  6. Sensitivity study of reliable, high-throughput resolution metricsfor photoresists

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Christopher N.; Naulleau, Patrick P.

    2007-07-30

    The resolution of chemically amplified resists is becoming an increasing concern, especially for lithography in the extreme ultraviolet (EUV) regime. Large-scale screening and performance-based down-selection is currently underway to identify resist platforms that can support shrinking feature sizes. Resist screening efforts, however, are hampered by the absence of reliable resolution metrics that can objectively quantify resist resolution in a high-throughput fashion. Here we examine two high-throughput metrics for resist resolution determination. After summarizing their details and justifying their utility, we characterize the sensitivity of both metrics to two of the main experimental uncertainties associated with lithographic exposure tools, namely: limited focus control and limited knowledge of optical aberrations. For an implementation at EUV wavelengths, we report aberration and focus limited error bars in extracted resolution of {approx} 1.25 nm RMS for both metrics making them attractive candidates for future screening and down-selection efforts.

  7. A flexible tactile sensitive sheet using a hetero-core fiber optic sensor

    Science.gov (United States)

    Fujino, S.; Yamazaki, H.; Hosoki, A.; Watanabe, K.

    2014-05-01

    In this report, we have designed a tactile sensitive sheet based on a hetero-core fiber-optic sensor, which realize an areal sensing by using single sensor potion in one optical fiber line. Recently, flexible and wide-area tactile sensing technology is expected to applied to acquired biological information in living space and robot achieve long-term care services such as welfare and nursing-care and humanoid technology. A hetero-core fiber-optic sensor has several advantages such as thin and flexible transmission line, immunity to EMI. Additionally this sensor is sensitive to moderate bending actions with optical loss changes and is independent of temperature fluctuation. Thus, the hetero-core fiber-optic sensor can be suitable for areal tactile sensing. We measure pressure characteristic of the proposed sensitive sheet by changing the pressure position and pinching characteristic on the surface. The proposed tactile sensitive sheet shows monotonic responses on the whole sensitive sheet surface although different sensitivity by the position is observed at the sensitive sheet surface. Moreover, the tactile sensitive sheet could sufficiently detect the pinching motion. In addition, in order to realize the discrimination between pressure and pinch, we fabricated a doubled-over sensor using a set of tactile sensitive sheets, which has different kinds of silicon robbers as a sensitive sheet surface. In conclusion, the flexible material could be given to the tactile sensation which is attached under proposed sensitive sheet.

  8. High sensitivity field asymmetric ion mobility spectrometer

    Science.gov (United States)

    Chavarria, Mario A.; Matheoud, Alessandro V.; Marmillod, Philippe; Liu, Youjiang; Kong, Deyi; Brugger, Jürgen; Boero, Giovanni

    2017-03-01

    A high sensitivity field asymmetric ion mobility spectrometer (FAIMS) was designed, fabricated, and tested. The main components of the system are a 10.6 eV UV photoionization source, an ion filter driven by a high voltage/high frequency n-MOS inverter circuit, and a low noise ion detector. The ion filter electronics are capable to generate square waveforms with peak-to-peak voltages up to 1000 V at frequencies up to 1 MHz with adjustable duty cycles. The ion detector current amplifier has a gain up to 1012 V/A with an effective equivalent input noise level down to about 1 fA/Hz1/2 during operation with the ion filter at the maximum voltage and frequency. The FAIMS system was characterized by detecting different standard chemical compounds. Additionally, we investigated the use of a synchronous modulation/demodulation technique to improve the signal-to-noise ratio in FAIMS measurements. In particular, we implemented the modulation of the compensation voltage with the synchronous demodulation of the ion current. The analysis of the measurements at low concentration levels led to an extrapolated limit of detection for acetone of 10 ppt with an averaging time of 1 s.

  9. Analytical analysis of sensitivity of optical waveguide sensor

    African Journals Online (AJOL)

    user

    International Journal of Engineering, Science and Technology. Vol. ... optical sensors have attracted considerable attention, especially in the application of biochemical species ... Section 2 provides the principle and basic theory of optical sensors and the modal ... The electric and magnetic fields of a mode can be written as.

  10. Technology Development for High Efficiency Optical Communications

    Science.gov (United States)

    Farr, William H.

    2012-01-01

    Deep space optical communications is a significantly more challenging operational domain than near Earth space optical communications, primarily due to effects resulting from the vastly increased range between transmitter and receiver. The NASA Game Changing Development Program Deep Space Optical Communications Project is developing four key technologies for the implementation of a high efficiency telecommunications system that will enable greater than 10X the data rate of a state-of-the-art deep space RF system (Ka-band) for similar transceiver mass and power burden on the spacecraft. These technologies are a low mass spacecraft disturbance isolation assembly, a flight qualified photon counting detector array, a high efficiency flight laser amplifier and a high efficiency photon counting detector array for the ground-based receiver.

  11. Optically transparent high temperature shape memory polymers.

    Science.gov (United States)

    Xiao, Xinli; Qiu, Xueying; Kong, Deyan; Zhang, Wenbo; Liu, Yanju; Leng, Jinsong

    2016-03-21

    Optically transparent shape memory polymers (SMPs) have potential in advanced optoelectronic and other common shape memory applications, and here optically transparent shape memory polyimide is reported for the first time. The polyimide possesses a glass transition temperature (Tg) of 171 °C, higher than the Tg of other transparent SMPs reported, and the influence of molecular structure on Tg is discussed. The 120 μm thick polyimide film exhibits transmittance higher than 81% in 450-800 nm, and the possible mechanism of its high transparency is analyzed, which will benefit further research on other transparent high temperature SMPs. The transparent polyimide showed excellent thermomechanical properties and shape memory performances, and retained high optical transparency after many shape memory cycles.

  12. High Optical Access Trap 2.0.

    Energy Technology Data Exchange (ETDEWEB)

    Maunz, Peter Lukas Wilhelm [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-26

    The High Optical Access (HOA) trap was designed in collaboration with the Modular Universal Scalable Ion-trap Quantum Computer (MUSIQC) team, funded along with Sandia National Laboratories through IARPA's Multi Qubit Coherent Operations (MQCO) program. The design of version 1 of the HOA trap was completed in September 2012 and initial devices were completed and packaged in February 2013. The second version of the High Optical Access Trap (HOA-2) was completed in September 2014 and is available at IARPA's disposal.

  13. The effect of input phase modulation to a phase-sensitive optical amplifier

    CERN Document Server

    Li, Tian; Horrom, Travis; Jones, Kevin M; Lett, Paul D

    2016-01-01

    Many optical applications depend on amplitude modulating optical beams using devices such as acousto-optical modulators (AOMs) or optical choppers. Methods to add amplitude modulation (AM) often inadvertently impart phase modulation (PM) onto the light as well. While this PM is of no consequence to many phase-insensitive applications, phase-sensitive processes can be affected. Here we study the effects of input phase and amplitude modulation on the output of a quantum-noise limited phase-sensitive optical amplifier (PSA) realized in hot $^{85}$Rb vapor. We investigate the dependence of PM on AOM alignment and demonstrate a novel approach to quantifying PM by using the PSA as a diagnostic tool. We then use this method to measure the alignment-dependent PM of an optical chopper which arises due to diffraction effects as the chopper blade passes through the optical beam.

  14. Ultra-sensitive broad-dynamic range optical magnetometer with instance response to magnetic field changes

    CERN Document Server

    Wlodarczyk, Przemyslaw; Zachorowski, Jerzy; Lipinski, Marcin

    2012-01-01

    We investigate one of the most sensitive devices for measuring magnetic fields, the, so-called, AMOR magnetometer. The device exploits a specific nonlinear optical phenomenon (amplitude-modulated nonlinear magneto-optical rotation) for ultra-precise magnetic field detection. It allows measuring the field with a sensitivity of 10^-14 T/Hz^-1/2 within a dynamic range of 10-4 T. Such high sensitivity and the dynamic range covering the Earth magnetic field are desired in context of many practical application of the device. By elaborating the electronic model of the magnetometer we study its different characteristics in various arrangements. It allows us to optimize the device regarding different requirements, e.g., technical simplicity, data processing, etc. It is shown that the device may be automated operating it in the self-oscillation mode. Particularly, we show that the magnetometer instantly responses to the magnetic field change. Our numerical analyses are confirmed with experimental results obtained in on...

  15. Optical temperature sensor with enhanced sensitivity by employing hybrid waveguides in a silicon Mach-Zehnder interferometer

    DEFF Research Database (Denmark)

    Guan, Xiaowei; Wang, Xiaoyan; Frandsen, Lars Hagedorn

    2016-01-01

    of the fabricated sensor with silicon/polymer hybrid waveguides is measured to be 172 pm/°C, which is two times larger than a conventional all-silicon optical temperature sensor (∼80 pm/°C). Moreover, a design with silicon/titanium dioxide hybrid waveguides is by calculation expected to have a sensitivity as high...

  16. High-speed analog fiber optic links for satellite communication

    Science.gov (United States)

    Daryoush, A. S.; Herczfeld, P. R.; Kunath, R. R.

    1988-01-01

    Large-aperture phased array antennas operating at millimeter wave frequencies are designed for space-based communications and imaging. Array elements are comprised of active transmit/receive (T/R) modules which are linked to the central processing unit through a high-speed fiberoptic network. This paper demonstrates optical control of active modules for satellite communication at 24 GHz. An approach called T/R level data mixing, which utilizes fiberoptic transmission of a data signal to individual T/R modules to be upconverted by an optically synchronized local oscillator, is demonstrated at 24 GHz. A free-running HEMT oscillator, used as local oscillator at 24 GHz, is synchronized using indirect subharmonic optical injection locking over a locking range of 14 MHz. Results of data link performance over 500-1000 MHz is also reported in terms of gain-bandwidth, linearity and third-order intercept, sensitivity, and dynamic range.

  17. Advanced Functionalities for Highly Reliable Optical Networks

    DEFF Research Database (Denmark)

    An, Yi

    This thesis covers two research topics concerning optical solutions for networks e.g. avionic systems. One is to identify the applications for silicon photonic devices for cost-effective solutions in short-range optical networks. The other one is to realise advanced functionalities in order to in......) using two exclusive OR (XOR) gates realised by four-wave mixing (FWM) in semiconductor optical amplifiers (SOAs) is experimentally demonstrated and very low (~ 1 dB) total operation penalty is achieved....... to increase the availability of highly reliable optical networks. A cost-effective transmitter based on a directly modulated laser (DML) using a silicon micro-ring resonator (MRR) to enhance its modulation speed is proposed, analysed and experimentally demonstrated. A modulation speed enhancement from 10 Gbit...... interconnects and network-on-chips. A novel concept of all-optical protection switching scheme is proposed, where fault detection and protection trigger are all implemented in the optical domain. This scheme can provide ultra-fast establishment of the protection path resulting in a minimum loss of data...

  18. Annealing effects on strain and stress sensitivity of polymer optical fibre based sensors

    DEFF Research Database (Denmark)

    Pospori, A.; Marques, C. A. F.; Zubel, M. G.

    2016-01-01

    The annealing effects on strain and stress sensitivity of polymer optical fibre Bragg grating sensors after their photoinscription are investigated. PMMA optical fibre based Bragg grating sensors are first photo-inscribed and then they were placed into hot water for annealing. Strain, stress...... and force sensitivity measurements are taken before and after annealing. Parameters such as annealing time and annealing temperature are investigated. The change of the fibre diameter due to water absorption and the annealing process is also considered. The results show that annealing the polymer optical...... fibre tends to increase the strain, stress and force sensitivity of the photo-inscribed sensor....

  19. Sensitization of an optical fiber methane sensor with graphene

    Science.gov (United States)

    Zhang, J. Y.; Ding, E. J.; Xu, S. C.; Li, Z. H.; Wang, X. X.; Song, F.

    2017-09-01

    We analyze the mechanism by which tin oxide can be utilized for the optical sensing of methane gas via surface adsorption and electromagnetic theory. Single-mode optical fibers with core diameters of 9 μm and cladding diameters of 12 μm were used. A 15 mm-long segment of each optical fiber was polished to the core via wheel side-polishing; the exposed fiber core areas were coated with graphene-doped tin oxide such that a novel graphene-based optical fiber methane sensor was fabricated. The experimental results show that the sensor exhibits excellent linear fitting and reproducibility, making it useful for the detection of low concentrations of methane.

  20. High performance fluoride optical coatings for DUV optics

    Science.gov (United States)

    Zhang, Lichao; Cai, Xikun

    2014-08-01

    In deep ultraviolet region that typical applications are used on the ArF wavelength, coated optics should meet stringent requirements of optical systems. To meet these requirements, systematical researches are carried out on fabrication and characterization methods of fluoride coatings. First, by optimizing of deposition processes, dense coatings with the refractive index of ~1.7 for LaF3 and ~1.4 for MgF2, together with extinction coefficients of ~2×10-4 on 193nm were realized. The transmission of AR coating for 193nm achieved by using optimized deposition techniques is 99.8%. Second, a method of designing shadowing masks was developed to solve the problem of correcting coating thickness distributions for complex DUV systems. By using the method, the thickness distribution error specification of 3% PV has been achieved on substrates with ~300mm diameters and large curvatures. Finally, the laser calorimetry method is used to evaluate the laser radiation stability of fluoride coatings. It is turned out that the damage coefficients of fluoride coatings, which are defined as the values of unrecoverable increase of the absorption during the laser irradiation process, are much lower than that of fused silica substrates. The above progresses could further support the realization of high performance DUV optical systems.

  1. Highly sensitive direct conversion ultrasound interferometer

    Science.gov (United States)

    Svitelskiy, Oleksiy; Grossmann, John; Suslov, Alexey

    2015-03-01

    Being invented more than fifty years ago, the ultrasonic pulse-echo technique has proven itself as a valuable and indispensable non-destructive tool to explore elastic properties of materials in engineering and scientific tasks. We propose a new design for the instrument based on mass-produced integral microchips. In our design the radiofrequency echo-pulse signal is processed by AD8302 RF gain and phase detector (www.analog.com).Its phase output is linearly proportional to the phase difference between the exciting and response signals. The gain output is proportional to the log of the ratio of amplitudes of the received to the exciting signals. To exclude the non-linear fragments and to enable exploring large phase changes, we employ parallel connection of two detectors, fed by in-phase and quadrature signals respectively. The instrument allowed us exploring phase transitions with precision of ΔV / V ~10-7 (V is the ultrasound speed). The high sensitivity of the logarithmic amplifiers embedded into AD8302 requires good grounding and screening of the receiving circuitry.

  2. UV-sensitive optical sensors based on ITO-gallium phosphide heterojunctions

    Energy Technology Data Exchange (ETDEWEB)

    Malik, Oleksandr; Hidalga-Wade, F. Javier de la; Zuniga-Islas, Carlos; Abundis Patino, Jesus H. [National Institute for Astrophysics, Optics, and Electronics (INAOE), Puebla (Mexico)

    2010-04-15

    Design and characteristics of wide-band UV sensors based on ITO/GaP heterostructures are discussed. Such sensors have perfect electrical parameters and high UV-visible sensitivity in comparison with surface-barrier structures using a semi-transparent thin metal film as an electrode. Many applications require UV sensors with an effective rejection of visible radiation and a wide temperature operating interval. For this aim, the theoretical modelling of extreme selective optical sensors with a double Ag/ITO thin film on the GaP surface, in which the thin silver film serves as a narrow bandpass filter at 320 nm, has been conducted. With this modelling the optimal thickness combination for the silver and ITO films was found for the maximum rejection of the sensitivity to visible radiation (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  3. Optical polarization tractography based on polarization-sensitive optical coherence tomography

    Science.gov (United States)

    Yao, Gang; Wang, Yuanbo; Ravanfar, Mohammadreza; Azinfar, Leila; Yao, Xuan; Zhang, Keqing; Duan, Dongsheng

    2016-03-01

    Fibrous tissues exist in many parts of the body, where the directional fiber organization is critical in maintaining their normal functions. Disruption of the normal fibrous structure is often linked to tissue dysfunction. An imaging tool that can reveal the detailed fiber architecture will be valuable for our understanding of the structure-function relationship in these tissues. Here, we described a new high-resolution tractography method developed from Jones matrix polarizationsensitive optical coherence tomography. We demonstrated its applications for visualization of fibrous structures in several different animal tissues.

  4. Theoretical modelling of a bi-dimensional U-shaped surface plasmon resonance based fibre optic sensor for sensitivity enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Verma, R K; Gupta, B D [Physics Department, Indian Institute of Technology Delhi, New Delhi-110016 (India)], E-mail: bdgupta@physics.iitd.ernet.in

    2008-05-07

    Theoretical analysis of a surface plasmon resonance based fibre optic sensor with a uniform semi-metal coated U-shaped probe is carried out using a bi-dimensional model. All the rays of the p-polarized light launched in the fibre and their electric vectors are assumed to be confined in the plane of bending of the U-shaped probe. The effect of the bending radius of the probe on the sensitivity of the sensor is studied. The study shows that as the bending radius of the probe decreases the sensitivity of the sensor increases. For the light launching conditions used, the maximum sensitivity achieved is several times more than that reported for a fibre optic tapered probe. In addition to high sensitivity, the most advantageous feature of a U-shaped probe is that it can be used as a point sensor.

  5. Comparison of different technologies for high-quality optical coatings

    Science.gov (United States)

    Flory, Francois

    1990-08-01

    Modern optical systems require still higher quality optical coatings. Conventional production techniques are not able to give such high quality layers. One of the main defaults comes from the relatively porous structure of the thin films; as a consequence the sensitiveness of the materials to the moisture gives noticeably unstable properties versus time. In this work, after a very short review of the different techniques nowaday used to perform high quality optical thin films, we will be especially interested in oxide layer production (Si02, Ta2O5, Ti02). To give a good comparison of the performances obtained with techniques such as TAD and ion plating we need extremely powerful characterization means: - In vacuo measurements of optical properties allowing the study of spontaneous water adsorption during air entrance; - Absorption measurement with photothermal deflection spectroscopy; - Scattering losses measurements and consequently determination of the grain size of the microstructure. Refractive index measurements, and optical anisotropy determined by guided mode study. Finally some views from electron microscopy justify the validity of the model used with our characterization techniques. To end, we will show the interest of ion plating technique when we are looking for very uniform deposition on large surfaces.

  6. High capacity optical links for datacentre connectivity

    DEFF Research Database (Denmark)

    Tafur Monroy, Idelfonso; Usuga, Mario; Vegas Olmos, Juan José

    There is a timely and growing demand for high capacity optical data transport solutions to provide connectivity inside data centres and between data centres located at different geographical locations. The requirements for reach are in the order of 2 km for intra-datacentre and up to 100 km for i...

  7. High Sensitivity, High Frequency and High Time Resolution Decimetric Spectroscope

    Science.gov (United States)

    Sawant, H. S.; Rosa, R. R.

    1990-11-01

    RESUMEN. Se ha desarrollado el primer espectroscopio decimetrico latino americano operando en una banda de 100 MHz con alta resoluci6n de fre- cuencia (100 KHz) y tiempo (10 ms), alrededor de cualquier centro de frecuencia en el intervalo de 2000-200 MHz. El prop6sito de esta nota es describir investigaciones solares y no solares que se planean, progra ma de investigaci6n y la situaci6n actual de desarrollo de este espectroscopio. ABSTRACT. First Latin American Decimetric Spectroscope operating over a band of 100 MHz with high resolution in frequency (100 KHz) and time (10 ms), around any center frequency in the range of 2000-200 MHz is being developed. The purpose of this note is to describe planned solar, and non-solar, research programmes and present status of development of this spectroscope. Keq wo : INSTRUMENTS - SPECTROSCOPY

  8. Highly sensitive detection using Herriott cell for laser absorption spectroscopy

    Science.gov (United States)

    Zhao, Chongyi; Song, Guangming; Du, Yang; Zhao, Xiaojun; Wang, Wenju; Zhong, Liujun; Hu, Mai

    2016-11-01

    The tunable diode laser absorption spectroscopy combined with the long absorption path technique is a significant method to detect harmful gas. The long optical path could come true by Herriott cell reducing the size of the spectrometers. A 15 cm long Herriott cell with 28.8 m optical absorption path after 96 times reflection was designed that enhanced detection sensitivity of absorption spectroscopy. According to the theory data of calculation, Herriott cell is analyzed and simulated by softwares Matlab and Lighttools.

  9. Optical high-performance computing: introduction to the JOSA A and Applied Optics feature.

    Science.gov (United States)

    Caulfield, H John; Dolev, Shlomi; Green, William M J

    2009-08-01

    The feature issues in both Applied Optics and the Journal of the Optical Society of America A focus on topics of immediate relevance to the community working in the area of optical high-performance computing.

  10. Optical signal processing for enabling high-speed, highly spectrally efficient and high capacity optical systems

    Science.gov (United States)

    Fazal, Muhammad Irfan

    The unabated demand for more capacity due to the ever-increasing internet traffic dictates that the boundaries of the state of the art maybe pushed to send more data through the network. Traditionally, this need has been satisfied by multiple wavelengths (wavelength division multiplexing), higher order modulation formats and coherent communication (either individually or combined together). WDM has the ability to reduce cost by using multiple channels within the same physical fiber, and with EDFA amplifiers, the need for O-E-O regenerators is eliminated. Moreover the availability of multiple colors allows for wavelength-based routing and network planning. Higher order modulation formats increases the capacity of the link by their ability to encode data in both the phase and amplitude of light, thereby increasing the bits/sec/Hz as compared to simple on-off keyed format. Coherent communications has also emerged as a primary means of transmitting and receiving optical data due to its support of formats that utilize both phase and amplitude to further increase the spectral efficiency of the optical channel, including quadrature amplitude modulation (QAM) and quadrature phase shift keying (QPSK). Polarization multiplexing of channels can double capacity by allowing two channels to share the same wavelength by propagating on orthogonal polarization axis and is easily supported in coherent systems where the polarization tracking can be performed in the digital domain. Furthermore, the forthcoming IEEE 100 Gbit/s Ethernet Standard, 802.3ba, provides greater bandwidth, higher data rates, and supports a mixture of modulation formats. In particular, Pol-MUX QPSK is increasingly becoming the industry's format of choice as the high spectral efficiency allows for 100 Gbit/s transmission while still occupying the current 50 GHz/channel allocation of current 10 Gbit/s OOK fiber systems. In this manner, 100 Gbit/s transfer speeds using current fiber links, amplifiers, and filters

  11. Characterization of Three High Efficiency and Blue Sensitive Silicon Photomultipliers

    CERN Document Server

    Otte, Adam Nepomuk; Nguyen, Thanh; Purushotham, Dhruv

    2016-01-01

    We report about the optical and electrical characterization of three high efficiency and blue sensitive Silicon photomultipliers from FBK, Hamamatsu, and SensL. Key features of the tested devices when operated at 90% breakdown probability are peak photon detection efficiencies between 40% and 55%, temperature dependencies of gain and PDE that are less than 1%/$^{\\circ}$C, dark rates of $\\sim$50\\,kHz/mm$^{2}$ at room temperature, afterpulsing of about 2%, and direct optical crosstalk between 6% and 20%. The characteristics of all three devices impressively demonstrate how the Silicon-photomultiplier technology has improved over the past ten years. It is further demonstrated how the voltage and temperature characteristics of a number of quantities can be parameterized on the basis of physical models. The models provide a deeper understanding of the device characteristics over a wide bias and temperature range. They also serve as examples how producers could provide the characteristics of their SiPMs to users. A...

  12. Characterization of three high efficiency and blue sensitive silicon photomultipliers

    Science.gov (United States)

    Otte, Adam Nepomuk; Garcia, Distefano; Nguyen, Thanh; Purushotham, Dhruv

    2017-02-01

    We report about the optical and electrical characterization of three high efficiency and blue sensitive Silicon photomultipliers from FBK, Hamamatsu, and SensL. Key features of the tested devices when operated at 90% breakdown probability are peak photon detection efficiencies between 40% and 55%, temperature dependencies of gain and PDE that are less than 1%/°C, dark rates of ∼50 kHz/mm2 at room temperature, afterpulsing of about 2%, and direct optical crosstalk between 6% and 20%. The characteristics of all three devices impressively demonstrate how the Silicon-photomultiplier technology has improved over the past ten years. It is further demonstrated how the voltage and temperature characteristics of a number of quantities can be parameterized on the basis of physical models. The models provide a deeper understanding of the device characteristics over a wide bias and temperature range. They also serve as examples how producers could provide the characteristics of their SiPMs to users. A standardized parameterization of SiPMs would enable users to find the optimal SiPM for their application and the operating point of SiPMs without having to perform measurements thus significantly reducing design and development cycles.

  13. Annealing effects on strain and stress sensitivity of polymer optical fibre based sensors

    DEFF Research Database (Denmark)

    Pospori, A.; Marques, C. A. F.; Zubel, M. G.;

    2016-01-01

    The annealing effects on strain and stress sensitivity of polymer optical fibre Bragg grating sensors after their photoinscription are investigated. PMMA optical fibre based Bragg grating sensors are first photo-inscribed and then they were placed into hot water for annealing. Strain, stress and ...

  14. Hybrid optical antenna with high directivity gain.

    Science.gov (United States)

    Bonakdar, Alireza; Mohseni, Hooman

    2013-08-01

    Coupling of a far-field optical mode to electronic states of a quantum absorber or emitter is a crucial process in many applications, including infrared sensors, single molecule spectroscopy, and quantum metrology. In particular, achieving high quantum efficiency for a system with a deep subwavelength quantum absorber/emitter has remained desirable. In this Letter, a hybrid optical antenna based on coupling of a photonic nanojet to a metallo-dielectric antenna is proposed, which allows such efficient coupling. A quantum efficiency of about 50% is predicted for a semiconductor with volume of ~λ³/170. Despite the weak optical absorption coefficient of 2000 cm(-1) in the long infrared wavelength of ~8 μm, very strong far-field coupling has been achieved, as evidenced by an axial directivity gain of 16 dB, which is only 3 dB below of theoretical limit. Unlike the common phased array antenna, this structure does not require coherent sources to achieve a high directivity. The quantum efficiency and directivity gain are more than an order of magnitude higher than existing metallic, dielectric, or metallo-dielectric optical antenna.

  15. PlanetPol: A Very High Sensitivity Polarimeter

    Science.gov (United States)

    Hough, J. H.; Lucas, P. W.; Bailey, J. A.; Tamura, M.; Hirst, E.; Harrison, D.; Bartholomew-Biggs, M.

    2006-09-01

    We have built and used on several occasions an optical broadband stellar polarimeter, PlanetPol, which employs photoelastic modulators and avalanche photodiodes and achieves a photon-noise-limited sensitivity of at least 1 in 106 in fractional polarization. Observations of a number of polarized standards taken from the literature show that the accuracy of polarization measurements is ~1%. We have developed a method for accurately measuring the polarization of altitude-azimuth mounted telescopes by observing bright nearby stars at different parallactic angles, and we find that the on-axis polarization of the William Herschel Telescope is typically ~15 × 10-6, measured with an accuracy of a few parts in 107. The nearby stars (distance less than 32 pc) are found to have very low polarizations, typically a few ×10-6, indicating that very little interstellar polarization is produced close to the Sun and that their intrinsic polarization is also low. Although the polarimeter can be used for a wide range of astronomy, the very high sensitivity was set by the goal of detecting the polarization signature of unresolved extrasolar planets.

  16. Optical multichannel analyzer techniques for high resolution optical spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Chao, J.L.

    1980-06-01

    The development of optical multichannel analyzer techniques for UV/VIS spectroscopy is presented. The research focuses on the development of spectroscopic techniques for measuring high resolution spectral lineshape functions from the exciton phosphorescence in H/sub 2/-1,2,4,5-tetrachlorobenzene. It is found that the temperature dependent frequency shifts and widths confirm a theoretical model based on an exchange theory. The exchange of low energy phonon modes which couple with excited state exciton transitions is shown to display the proper temperature dependent behavior. In addition to the techniques for using the optical multichannel analyzer (OMA) to perform low light level target integration, the use of the OMA for capturing spectral information in transient pulsed laser applications is discussed. An OMP data acquisition system developed for real-time signal processng is described. Both hardware and software interfacing considerations for control and data acquisition by a microcomputer are described. The OMA detector is described in terms of the principles behind its photoelectron detection capabilities and its design is compared with other optoelectronic devices.

  17. A new sensitive system for measurement of thermally and optically stimulated luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Markey, B.G.; Boetter-Jensen, L.; Poolton, N.R.J.; Christensen, H.E.; Willumsen, F. [Risoe National Lab., Roskilde (Denmark)

    1996-12-31

    An automatic system developed at Riso National Laboratory for measuring thermally and optically stimulated luminescence (TL, OSL) is widely used for radiation dose measurements. In the present model, high excitation and detection efficiencies were attempted, but inevitably there is a constant demand for improvements that would allow lower doses (or less sensitive materials) to be measured, with increased accuracy. This article reports on a new generation of designs that are intended to meet these demands. Substantial increases in sensitivity of the instruments are made by replacing the lens optics of the system with a combination of ellipsoidal mirrors and light guides, which also serve to make the system more flexible in choice of excitation source when OSL measurements are required. A variety of new light sources might be employed, adapted to allow them most efficient wavelengths of excitation to be used for the particular dosemeter under study. The capabilities and characteristics of the new design are described, and comparison with the existing TL/OSL system is made throughout the article. (author).

  18. Stable optical trapping and sensitive characterization of nanostructures using standing-wave Raman tweezers

    Science.gov (United States)

    Wu, Mu-ying; Ling, Dong-xiong; Ling, Lin; Li, William; Li, Yong-qing

    2017-01-01

    Optical manipulation and label-free characterization of nanoscale structures open up new possibilities for assembly and control of nanodevices and biomolecules. Optical tweezers integrated with Raman spectroscopy allows analyzing a single trapped particle, but is generally less effective for individual nanoparticles. The main challenge is the weak gradient force on nanoparticles that is insufficient to overcome the destabilizing effect of scattering force and Brownian motion. Here, we present standing-wave Raman tweezers for stable trapping and sensitive characterization of single isolated nanostructures with a low laser power by combining a standing-wave optical trap with confocal Raman spectroscopy. This scheme has stronger intensity gradients and balanced scattering forces, and thus can be used to analyze many nanoparticles that cannot be measured with single-beam Raman tweezers, including individual single-walled carbon nanotubes (SWCNT), graphene flakes, biological particles, SERS-active metal nanoparticles, and high-refractive semiconductor nanoparticles. This would enable sorting and characterization of specific SWCNTs and other nanoparticles based on their increased Raman fingerprints. PMID:28211526

  19. Stable optical trapping and sensitive characterization of nanostructures using standing-wave Raman tweezers

    Science.gov (United States)

    Wu, Mu-Ying; Ling, Dong-Xiong; Ling, Lin; Li, William; Li, Yong-Qing

    2017-02-01

    Optical manipulation and label-free characterization of nanoscale structures open up new possibilities for assembly and control of nanodevices and biomolecules. Optical tweezers integrated with Raman spectroscopy allows analyzing a single trapped particle, but is generally less effective for individual nanoparticles. The main challenge is the weak gradient force on nanoparticles that is insufficient to overcome the destabilizing effect of scattering force and Brownian motion. Here, we present standing-wave Raman tweezers for stable trapping and sensitive characterization of single isolated nanostructures with a low laser power by combining a standing-wave optical trap with confocal Raman spectroscopy. This scheme has stronger intensity gradients and balanced scattering forces, and thus can be used to analyze many nanoparticles that cannot be measured with single-beam Raman tweezers, including individual single-walled carbon nanotubes (SWCNT), graphene flakes, biological particles, SERS-active metal nanoparticles, and high-refractive semiconductor nanoparticles. This would enable sorting and characterization of specific SWCNTs and other nanoparticles based on their increased Raman fingerprints.

  20. Towards green high capacity optical networks

    Science.gov (United States)

    Glesk, I.; Mohd Warip, M. N.; Idris, S. K.; Osadola, T. B.; Andonovic, I.

    2012-02-01

    The demand for fast, secure, energy efficient high capacity networks is growing. It is fuelled by transmission bandwidth needs which will support among other things the rapid penetration of multimedia applications empowering smart consumer electronics and E-businesses. All the above trigger unparallel needs for networking solutions which must offer not only high-speed low-cost "on demand" mobile connectivity but should be ecologically friendly and have low carbon footprint. The first answer to address the bandwidth needs was deployment of fibre optic technologies into transport networks. After this it became quickly obvious that the inferior electronic bandwidth (if compared to optical fiber) will further keep its upper hand on maximum implementable serial data rates. A new solution was found by introducing parallelism into data transport in the form of Wavelength Division Multiplexing (WDM) which has helped dramatically to improve aggregate throughput of optical networks. However with these advancements a new bottleneck has emerged at fibre endpoints where data routers must process the incoming and outgoing traffic. Here, even with the massive and power hungry electronic parallelism routers today (still relying upon bandwidth limiting electronics) do not offer needed processing speeds networks demands. In this paper we will discuss some novel unconventional approaches to address network scalability leading to energy savings via advance optical signal processing. We will also investigate energy savings based on advanced network management through nodes hibernation proposed for Optical IP networks. The hibernation reduces the network overall power consumption by forming virtual network reconfigurations through selective nodes groupings and by links segmentations and partitionings.

  1. Interfacial Polycondensation Synthesis of Optically Sensitive Polyurea Microcapsule

    Directory of Open Access Journals (Sweden)

    Weidong Lai

    2014-01-01

    Full Text Available TMPTA prepolymer resin and photoinitiators of ITX/TPO had been encapsulated in core-shell structured microcapsules as optical responding ingredients based on interfacial polycondensation method, and polyurea structured microcapsule shell had been formed on the sheared O/W interface. The synthesized microcapsule had regular core-shell structure with the diameter of about 0.455 μm and shell thickness of about 40 nm. UV-visible absorption spectra indicated that the encapsulated ITX and TPO photoinitiators could efficiently absorb UV irradiation. Under exposure, the C=C bonds absorbance of the microencapsulated TMPTA decreased rapidly and then nearly unchanged during further exposure after 30 s. This implied that the optical response was achieved by C=C bond cleavage of TMPTA monomer initiated by the photoinitiator radicals, to form network polymers in microcapsules. The relative crosslinking rate was about 50%. Due to core polymer formation, the thermal phase change temperature of exposed microcapsules was narrowed and ranged from 105 to 205°C, compared with that from 125 to 260°C of unexposed microcapsules. Furthermore, the image density decrease at longer irradiation time had also verified the optical responding function of the synthesized microcapsules in macroscopic viewpoint.

  2. Highly sensitive temperature sensor based on an isopropanol-filled photonic crystal fiber long period grating

    Science.gov (United States)

    Du, Chao; Wang, Qi; Zhao, Yong; Li, Jin

    2017-03-01

    A high sensitivity measurement method for temperature has been proposed and investigated based on an isopropanol-filled photonic crystal fiber long period grating (PCF-LPG). Due to the high thermo-optic coefficient (TOC) of isopropanol, the sensitivity of the proposed temperature sensor could be effectively improved by filling isopropanol in the air waveguides of PCF. It can be found that the resonant dip will be split in two dips after filling isopropanol and the two dips have different sensitivities to surrounding temperature. Because of PCF-LPG is sensitive to the refractive index (RI) of internal filled liquid, the isopropanol-filled PCF-LPG temperature sensor has a high sensitivities of 1.356 nm/°C in the range of 20-50 °C. The simplicity and the excellent performance of our proposed device make it potential for the applications of high-precision temperature measurement is required.

  3. Bidirectional all-optical switches based on highly nonlinear optical fibers

    Science.gov (United States)

    Liu, Wenjun; Yang, Chunyu; Liu, Mengli; Yu, Weitian; Zhang, Yujia; Lei, Ming; Wei, Zhiyi

    2017-05-01

    All-optical switches have become one of the research focuses of nonlinear optics due to their fast switching speed. They have been applied in such fields as ultrafast optics, all-optical communication and all-optical networks. In this paper, based on symbolic computation, bidirectional all-optical switches are presented using analytic two-soliton solutions. Various types of soliton interactions are analyzed through choosing the different parameters of high-order dispersion and nonlinearity. Results indicate that bidirectional all-optical switches can be effectively achieved using highly nonlinear optical fibers.

  4. Thermal and chemical treatment of polymer optical fiber Bragg grating sensors for enhanced mechanical sensitivity

    DEFF Research Database (Denmark)

    Pospori, Andreas; Marques, C. A. F.; Saez-Rodriguez, D.

    2017-01-01

    An investigation of the thermal annealing effects on the strain, stress, and force sensitivities of polymer optical fiber Bragg grating sensors is performed. We demonstrate for the first time that the fiber annealing can enhance both stress and force sensitivities of Bragg grating sensors, with t...

  5. Semiconductor lasers as integrated optical biosensors: sensitivity optimisation

    Energy Technology Data Exchange (ETDEWEB)

    Coote, J; Sweeney, S J [Advanced Technology Institute, University of Surrey, Guildford, UK GU2 7XH (United Kingdom)

    2007-07-15

    Semiconductor lasers contain both a light source and waveguide, rendering them suitable for adaptation to evanescent field biosensing. One-dimensional simulations using the beam propagation method have been carried out for planar semiconductor waveguide structures, with a view to maximising sensitivity of the effective index to changes in the refractive index and thickness of a film on the waveguide surface. Various structural parameters are investigated and it is found that thinning the upper cladding layer maximises the sensitivity. Implications for laser operation are considered, and an optimised structure is proposed. Surface layer index and thickness resolutions of 0.2 and 2nm are predicted.

  6. High-sensitivity visible-blind UV detectors made with organic semiconductors

    Science.gov (United States)

    Yu, Gang; Cao, Yong; Srdanov, Gordana

    1999-04-01

    High sensitivity visible-blind UV detectors were fabricated with organic semiconductors. The photo-sensitivity at 350 nm reaches 75 mA/Watt, corresponding to quantum efficiency of approximately 27% el/ph. The visible/UV suppression ratio is more than 10(superscript 4) without optical filters. These UV detectors are of linear intensity dependence with fast response time. The simple fabrication process allows these UV detectors to be made in large size, in flexible forms or onto non-planar substrates with low cost. The fabrication process also allows these UV detectors to be integrated with electronic devices or optical devices.

  7. High accuracy measure of atomic polarizability in an optical lattice clock

    OpenAIRE

    Sherman, J. A.; Lemke, N. D.; Hinkley, N.; Pizzocaro, M.; Fox, R. W.; Ludlow, A. D.; Oates, C. W.

    2011-01-01

    Despite being a canonical example of quantum mechanical perturbation theory, as well as one of the earliest observed spectroscopic shifts, the Stark effect contributes the largest source of uncertainty in a modern optical atomic clock through blackbody radiation. By employing an ultracold, trapped atomic ensemble and high stability optical clock, we characterize the quadratic Stark effect with unprecedented precision. We report the ytterbium optical clock's sensitivity to electric fields (suc...

  8. ASIC-enabled High Resolution Optical Time Domain Reflectometer

    Science.gov (United States)

    Skendzic, Sandra

    (5) conclusion. Thus, it begins by providing background, basic OTDR operation, overview of ASIC functionality, and past experiments done with the ASIC for multimode fiber. Chapter 2 begins the investigation of a high resolution OTDR for single mode fiber. A though explanation of how the OTDR ASIC operates is presented in this chapter, as well as details on the OTDR scheme that has been implemented. Chapter 3 analyzes the performance of the OTDR. Chapter 4 introduces a hybrid silicon semiconductor optical amplifier and discusses its theoretical implication on the OTDR in terms of improving receiver sensitivity. Lastly, a summary of the findings and discussion of other applications lie in Chapter 5.

  9. H-infinity mix sensitivity controller design based on GIMC for electro-optical stabilization and tracking system

    Science.gov (United States)

    Liu, Zi-dong; Bao, Qi-liang; Xia, Yunxia; Liu, Xiang

    2013-08-01

    Electro-optical stabilization and tracking system is critical and difficult issue in satellite laser communication. Moreover, line-of-sight stabilized system is the kernel of implementing electro-optical stabilization and tracking system, which can be used to isolate the vibration of the moving platform of the satellite and the disturbance of the space environment. In this paper, we propose a new method, which using H∞ mix sensitivity based on generalized internal model controller (GIMC), to design the control system of the electro-optical stabilized platform. It is well known that there is an intrinsic conflict between performance and robustness in the standard feedback framework. Generalized internal model controller is a new architecture which can separate the performance and robustness design in controller design. This architecture has two parts: a high performance controller, say K0,which is designed by PI controller in this paper, and then a robustification controller, say Q, which is designed to improve the ability of the anti disturbance by using H-infinity mix sensitivity controller design method. In this paper, we also present the steps of controller design by using this method to make it easier to use. Based on the proposed method, numerical simulation and experiment are both carried out for a gyro stabilized platform of electro-optical tacking system. Both the numerical simulated and the experimental results show that the electro-optical stabilized platform using the H-infinity mix sensitivity controller design method based on GIMC is accurate and effective. Comparing with the same PI controller in standard feedback framework, the proposed method can guarantee the high tracking performance as same as the PI controller and improve the external disturbance restraining ability a lot. In conclusion, H-infinity mix sensitivity controller design method based on GIMC is a new approach for gyro stabilized platform of electro-optical stabilization and tracking

  10. High sensitivity probe absorption technique for time-of-flight measurements on cold atoms

    Indian Academy of Sciences (India)

    A K Mohapatra; C S Unnikrishnan

    2006-06-01

    We report on a phase-sensitive probe absorption technique with high sensitivity, capable of detecting a few hundred ultra-cold atoms in flight in an observation time of a few milliseconds. The large signal-to-noise ratio achieved is sufficient for reliable measurements on low intensity beams of cold atoms. We demonstrate the high sensitivity and figure of merit of the simple method by measuring the time-of-flight of atoms moving upwards from a magneto-optical trap released in the gravitational field.

  11. Sensitive, Specific Complementary - Strand Optical Detection of Viral RNA

    Science.gov (United States)

    1997-06-01

    promise Its components have been characterized and proven to show unparalleled sensitivity; in addition, an innovative method for improving...sensing. 14. SUBJECT TERMS 15. NUMBER OF PAGES RNA, enterovirii, biosensor, evanscent waves, refractometry , 31 phase detection, complementary strand...Phase Measurements (10) Tri-Phase Detection Method . (11) Phase Detectors (12) Phase Processor Board (13) Laboratory Experim ents

  12. Forty-Four Pass Fibre Optic Loop for Improving the Sensitivity of Surface Plasmon Resonance Sensors

    CERN Document Server

    Su, Chin B

    2007-01-01

    A forty-four pass fibre optic surface plasmon resonance sensor that enhances detection sensitivity according to the number of passes is demonstrated for the first time. The technique employs a fibre optic recirculation loop that passes the detection spot forty- four times, thus enhancing sensitivity by a factor of forty-four. Presently, the total number of passes is limited by the onset of lasing action of the recirculation loop. This technique offers a significant sensitivity improvement for various types of plasmon resonance sensors that may be used in chemical and biomolecule detections.

  13. First-harmonic sensitivity functions for a linearised diffusion model of ultrasound-modulated optical tomography

    Science.gov (United States)

    Powell, Samuel; Arridge, Simon R.; Leung, Terence S.

    2015-03-01

    Ultrasound-modulated optical tomography is an emerging biomedical imaging modality which uses the spatially localised acoustically-driven modulation of coherent light as a probe of the structure and optical properties of biological tissues. In this work we model the first-harmonic flux generated by the coupled physics using a simple linearised diffusion-style forward model. We derive analytical expressions for the sensitivity of this measurement type with respect to the optical absorption and scattering coefficients. These correlation measurement density functions can be employed as part of an image-reconstruction procedure capable of reconstructing quantitative images of the optical properties of a medium under investigation.

  14. High-resolution CT of lesions of the optic nerve

    Energy Technology Data Exchange (ETDEWEB)

    Peyster, R.G.; Hoover, E.D.; Hershey, B.L.; Haskin, M.E.

    1983-05-01

    The optic nerves are well demonstrated by high-resolution computed tomography. Involvement of the optic nerve by optic gliomas and optic nerve sheath meningiomas is well known. However, nonneoplastic processes such as increased intracranial pressure, optic neuritis, Grave ophthalmopathy, and orbital pseudotumor may also alter the appearance of the optic nerve/sheath on computed tomography. Certain clinical and computed tomographic features permit distinction of these nonneoplastic tumefactions from tumors.

  15. Experimental results of fiber optic contrast-sensitive dislocation sensor

    Science.gov (United States)

    Zyczkowski, M.; Szustakowski, M.; Palka, N.

    2005-05-01

    The dislocation sensor based on the contrast phenomenon in an unbalanced fiber optic Michelson interferometer with a 3 x 3 coupler and a semiconductor multimode laser. Periodic contrast oscillations, which depend on a laser spectrum, occur if a measuring arm of the interferometer is elongated. A conception of the elongation sensor that based on linearization of contrast oscillations is shown. Next, a setup of the sensor and signal processing scheme of the sensor is presented. During measurements, for 1-m long sensor we obtained 5-mm measuring range with +/-28-μm uncertainty. Explanation of these differences and conclusion to further research are formulated.

  16. Optics of high-performance electron microscopes.

    Science.gov (United States)

    Rose, H H

    2008-01-01

    During recent years, the theory of charged particle optics together with advances in fabrication tolerances and experimental techniques has lead to very significant advances in high-performance electron microscopes. Here, we will describe which theoretical tools, inventions and designs have driven this development. We cover the basic theory of higher-order electron optics and of image formation in electron microscopes. This leads to a description of different methods to correct aberrations by multipole fields and to a discussion of the most advanced design that take advantage of these techniques. The theory of electron mirrors is developed and it is shown how this can be used to correct aberrations and to design energy filters. Finally, different types of energy filters are described.

  17. Jones matrix analysis for a polarization-sensitive optical coherence tomography system using fiber-optic components

    Science.gov (United States)

    Hyle Park, B.; Pierce, Mark C.; Cense, Barry; de Boer, Johannes F.

    2004-11-01

    We present an analysis for polarization-sensitive optical coherence tomography that facilitates the unrestricted use of fiber and fiber-optic components throughout an interferometer and yields sample birefringence, diattenuation, and relative optic axis orientation. We use a novel Jones matrix approach that compares the polarization states of light reflected from the sample surface with those reflected from within a biological sample for pairs of depth scans. The incident polarization alternated between two states that are perpendicular in a Poincaré sphere representation to ensure proper detection of tissue birefringence regardless of optical fiber contributions. The method was validated by comparing the calculated diattenuation of a polarizing sheet, chicken tendon, and muscle with that obtained by independent measurement. The relative importance of diattenuation versus birefringence to angular displacement of Stokes vectors on a Poincaré sphere was quantified.

  18. Fabrication and tolerances of optics for high concentration photovoltaics

    OpenAIRE

    Benitez Gimenez, Pablo; Miñano Dominguez, Juan Carlos; Ahmadpanaih, Hamed; Mendes Lopes, Joao; Zamora Herranz, Pablo

    2014-01-01

    High Concentration Photovoltaics (HCPV) require an optical system with high efficiency, low cost and large tolerance. We describe the particularities of the HCPV applications, which constrain the optics design and the manufacturing techonologies.

  19. Optical switching of radical pair conformation enhances magnetic sensitivity

    CERN Document Server

    Guerreschi, Gian Giacomo; Steiner, Ulrich E; Briegel, Hans J

    2013-01-01

    The yield of chemical reactions involving intermediate radical pairs is influenced by magnetic fields well beyond the levels expected from energy considerations. This dependence can be traced back to the microscopic dynamics of electron spins and constitutes the basis of the chemical compass. Here we propose a new experimental approach based on molecular photoswitches to achieve additional control on the chemical reaction and to allow short-time resolution of the spin dynamics. Our proposal enables experiments to test some of the standard assumptions of the radical pair model and improves the sensitivity of chemical magnetometers by two orders of magnitude.

  20. Microshell Arrays Enhanced Sensitivity in Detection of Specific Antibody for Reduced Graphene Oxide Optical Sensor

    Directory of Open Access Journals (Sweden)

    Wen-Shuai Jiang

    2017-01-01

    Full Text Available Protein-protein interactions play an important role in the investigation of biomolecules. In this paper, we reported on the use of a reduced graphene oxide microshell (RGOM-based optical biosensor for the determination of goat anti-rabbit IgG. The biosensor was prepared through a self-assembly of monolayers of monodisperse polystyrene microspheres, combined with a high-temperature reduction, in order to decorate the RGOM with rabbit IgG. The periodic microshells allowed a simpler functionalization and modification of RGOM with bioreceptor units, than reduced graphene oxide (RGO. With additional antibody-antigen binding, the RGOM-based biosensor achieved better real-time and label-free detection. The RGOM-based biosensor presented a more satisfactory response to goat anti-rabbit IgG than the RGO-based biosensor. This method is promising for immobilizing biomolecules on graphene surfaces and for the fabrication of biosensors with enhanced sensitivity.

  1. Microshell Arrays Enhanced Sensitivity in Detection of Specific Antibody for Reduced Graphene Oxide Optical Sensor

    Science.gov (United States)

    Jiang, Wen-Shuai; Xin, Wei; Chen, Shao-Nan; Li, Cun-Bo; Gao, Xiao-Guang; Pan, Lei-Ting; Liu, Zhi-Bo; Tian, Jian-Guo

    2017-01-01

    Protein-protein interactions play an important role in the investigation of biomolecules. In this paper, we reported on the use of a reduced graphene oxide microshell (RGOM)-based optical biosensor for the determination of goat anti-rabbit IgG. The biosensor was prepared through a self-assembly of monolayers of monodisperse polystyrene microspheres, combined with a high-temperature reduction, in order to decorate the RGOM with rabbit IgG. The periodic microshells allowed a simpler functionalization and modification of RGOM with bioreceptor units, than reduced graphene oxide (RGO). With additional antibody-antigen binding, the RGOM-based biosensor achieved better real-time and label-free detection. The RGOM-based biosensor presented a more satisfactory response to goat anti-rabbit IgG than the RGO-based biosensor. This method is promising for immobilizing biomolecules on graphene surfaces and for the fabrication of biosensors with enhanced sensitivity. PMID:28125011

  2. Near-field measurement of modal interference in optical nanofibers for sub-Angstrom radius sensitivity

    CERN Document Server

    Fatemi, Fredrik K; Solano, Pablo; Fenton, Eliot F; Beadie, Guy; Rolston, Steven L; Orozco, Luis A

    2016-01-01

    Optical nanofibers (ONF) of subwavelength dimensions confine light in modes with a strong evanescent field that can trap, probe, and manipulate nearby quantum systems. To measure the evanescent field and propagating modes, and to optimize ONF performance, a surface probe is desirable during fabrication. We demonstrate a nondestructive measurement of light propagation in ONFs by sampling the local evanescent field with a microfiber. This approach reveals the behavior of all propagating modes, and because the modal beat lengths in cylindrical waveguides depend strongly on radius, simultaneously provides exquisite sensitivity to the ONF radius. We show that our measured spatial frequencies provide a map of the average ONF radius (over a 600 micrometer window) along the 10 mm ONF waist with 40 picometer resolution and high signal-to-noise ratio. The measurements agree with scanning electron microscopy (SEM) to within SEM instrument resolution. This fast method is immune to polarization, intrinsic birefringence, m...

  3. High data rate optical transceiver terminal

    Science.gov (United States)

    Clarke, E. S.

    1973-01-01

    The objectives of this study were: (1) to design a 400 Mbps optical transceiver terminal to operate from a high-altitude balloon-borne platform in order to permit the quantitative evaluation of a space-qualifiable optical communications system design, (2) to design an atmospheric propagation experiment to operate in conjunction with the terminal to measure the degrading effects of the atmosphere on the links, and (3) to design typical optical communications experiments for space-borne laboratories in the 1980-1990 time frame. As a result of the study, a transceiver package has been configured for demonstration flights during late 1974. The transceiver contains a 400 Mbps transmitter, a 400 Mbps receiver, and acquisition and tracking receivers. The transmitter is a Nd:YAG, 200 Mhz, mode-locked, CW, diode-pumped laser operating at 1.06 um requiring 50 mW for 6 db margin. It will be designed to implement Pulse Quaternary Modulation (PQM). The 400 Mbps receiver utilizes a Dynamic Crossed-Field Photomultiplier (DCFP) detector. The acquisition receiver is a Quadrant Photomultiplier Tube (QPMT) and receives a 400 Mbps signal chopped at 0.1 Mhz.

  4. Current Trends of High capacity Optical Interconnection Data Link in High Performance Optical Communication Systems

    Directory of Open Access Journals (Sweden)

    Ahmed Nabih Zaki Rashed

    2013-02-01

    Full Text Available Optical technologies are ubiquitous in telecommunications networks and systems, providing multiple wavelength channels of transport at 2.5 Gbit/sec to 40 Gbit/sec data rates over single fiber optic cables. Market pressures continue to drive the number of wavelength channels per fiber and the data rate per channel. This trend will continue for many years to come as electronic commerce grows and enterprises demand higher and reliable bandwidth over long distances. Electronic commerce, in turn, is driving the growth curves for single processor and multiprocessor performance in data base transaction and Web based servers. Ironically, the insatiable taste for enterprise network bandwidth, which has driven up the volume and pushed down the price of optical components for telecommunications, is simultaneously stressing computer system bandwidth increasing the need for new interconnection schemes and providing for the first time commercial opportunities for optical components in computer systems. The evolution of integrated circuit technology is causing system designs to move towards communication based architectures. We have presented the current tends of high performance system capacity of optical interconnection data transmission link in high performance optical communication and computing systems over wide range of the affecting parameters.

  5. Symbolic modeling of high energy beam optics

    CERN Document Server

    Autin, Bruno

    1999-01-01

    A classical problem of computational physics consists of finding the minimum of a chi /sup 2/ like function of many variables. Powerful optimization algorithms have been developed but do not guarantee convergence towards an absolute minimum. Analytical methods can improve the insight into a physical problem but calculations quickly exceed the power of a human brain. There comes the interest of optical design of high energy particle accelerators. The physics background is sketched and emphasis is put on the methodology. In practice, algebraic models may not be precise enough but they usually provide excellent initial conditions for a final numerical optimization. (4 refs).

  6. Pseudo working-point control measurement scheme for acoustic sensitivity of interferometric fiber-optic hydrophones

    Institute of Scientific and Technical Information of China (English)

    Zefeng Wang; Yongming Hu; Zhou Meng; Ming Ni

    2008-01-01

    A novel pseudo working-point control measurement scheme for the acoustic sensitivity of interferometric fiber-optic hydrophones is described and demonstrated.The measurement principle is introduced in detail.An experimental system,which interrogates an interferometric fiber-optic hydrophone with this method,is designed.The acoustic pressure phase sensitivity of the fiber-optic hydrophone is measured over the frequency range of 20-2500Hz.The measured acoustic sensitivity is about-156.5dB re 1rad/μPa with a fluctuation lower than ±1.2dB,which is in good agreement with the results obtained by the method of phase generated carrier.The experimental results testify the validity of this new method which has the advantages of no electric elements in the sensing head,the simplicity of signal processing,and wide working bandwidth.

  7. High-Sensitivity GaN Microchemical Sensors

    Science.gov (United States)

    Son, Kyung-ah; Yang, Baohua; Liao, Anna; Moon, Jeongsun; Prokopuk, Nicholas

    2009-01-01

    Systematic studies have been performed on the sensitivity of GaN HEMT (high electron mobility transistor) sensors using various gate electrode designs and operational parameters. The results here show that a higher sensitivity can be achieved with a larger W/L ratio (W = gate width, L = gate length) at a given D (D = source-drain distance), and multi-finger gate electrodes offer a higher sensitivity than a one-finger gate electrode. In terms of operating conditions, sensor sensitivity is strongly dependent on transconductance of the sensor. The highest sensitivity can be achieved at the gate voltage where the slope of the transconductance curve is the largest. This work provides critical information about how the gate electrode of a GaN HEMT, which has been identified as the most sensitive among GaN microsensors, needs to be designed, and what operation parameters should be used for high sensitivity detection.

  8. Frequency-resolved noise figure measurements of phase (in)sensitive fiber optical parametric amplifiers.

    Science.gov (United States)

    Malik, R; Kumpera, A; Lorences-Riesgo, A; Andrekson, P A; Karlsson, M

    2014-11-17

    We measure the frequency-resolved noise figure of fiber optical parametric amplifiers both in phase-insensitive and phase-sensitive modes in the frequency range from 0.03 to 3 GHz. We also measure the variation in noise figure due to the degradation in pump optical signal to noise ratio and also as a function of the input signal powers. Noise figure degradation due to stimulated Brillouin scattering is observed.

  9. A high-sensitivity push-pull magnetometer

    Science.gov (United States)

    Breschi, E.; Grujić, Z. D.; Knowles, P.; Weis, A.

    2014-01-01

    We describe our approach to atomic magnetometry based on the push-pull optical pumping technique. Cesium vapor is pumped and probed by a resonant laser beam whose circular polarization is modulated synchronously with the spin evolution dynamics induced by a static magnetic field. The magnetometer is operated in a phase-locked loop, and it has an intrinsic sensitivity below 20fT/√Hz , using a room temperature paraffin-coated cell. We use the magnetometer to monitor magnetic field fluctuations with a sensitivity of 300fT/√Hz .

  10. A high-sensitivity push-pull magnetometer

    CERN Document Server

    Breschi, E; Knowles, P; Weis, A

    2013-01-01

    We describe our approach to atomic magnetometry based on the push-pull optical pumping technique. Cesium vapor is pumped and probed by a resonant laser beam whose circular polarization is modulated synchronously with the spin evolution dynamics induced by a static magnetic field. The magnetometer is operated in a phase-locked loop, and it has an intrinsic sensitivity below 20fT/\\sqrt(Hz) using a room temperature paraffin-coated cell. We use the magnetometer to monitor magnetic field fluctuations with a sensitivity of 300fT/\\sqrt(Hz).

  11. Sensitivity of a long-period optical fiber grating bend sensor

    DEFF Research Database (Denmark)

    Rathje, Jacob; Svalgaard, Mikael; Hübner, Jörg

    1998-01-01

    We have investigated the sensitivity of long-period fiber gratings used in curvature measuring fibre optic sensors and found a bend coefficient of 0.77 dB cm/mrad. In the current setup this corresponds to the ability of detecting curvatures with a radius up to approximately 200 m......We have investigated the sensitivity of long-period fiber gratings used in curvature measuring fibre optic sensors and found a bend coefficient of 0.77 dB cm/mrad. In the current setup this corresponds to the ability of detecting curvatures with a radius up to approximately 200 m...

  12. 16 channel WDM regeneration in a single phase-sensitive amplifier through optical Fourier transformation

    DEFF Research Database (Denmark)

    Guan, Pengyu; Da Ros, Francesco; Lillieholm, Mads

    2016-01-01

    We demonstrate simultaneous phase regeneration of 16-WDM DPSK channels using optical Fourier transformation and a single phase-sensitive amplifier. The BERs of 16-WDM×10-Gbit/s phase noise degraded DPSK signals are improved by 0.4-1.3 orders of magnitude......We demonstrate simultaneous phase regeneration of 16-WDM DPSK channels using optical Fourier transformation and a single phase-sensitive amplifier. The BERs of 16-WDM×10-Gbit/s phase noise degraded DPSK signals are improved by 0.4-1.3 orders of magnitude...

  13. Optical alignment of high resolution Fourier transform spectrometers

    Science.gov (United States)

    Breckinridge, J. B.; Ocallaghan, F. G.; Cassie, A. G.

    1980-01-01

    Remote sensing, high resolution FTS instruments often contain three primary optical subsystems: Fore-Optics, Interferometer Optics, and Post, or Detector Optics. We discuss the alignment of a double-pass FTS containing a cat's-eye retro-reflector. Also, the alignment of fore-optics containing confocal paraboloids with a reflecting field stop which relays a field image onto a camera is discussed.

  14. Detection of neural activity using phase-sensitive optical low-coherence reflectometry

    Science.gov (United States)

    Akkin, Taner; Davã©, Digant P.; Milner, Thomas E.; Rylander, H. Grady, III

    2004-05-01

    We demonstrate non-contact sub-nanometer optical measurement of neural surface displacement associated with action potential propagation. Experimental results are recorded from nerve bundles dissected from crayfish walking leg using a phase-sensitive optical low coherence reflectometer. No exogenous chemicals or reflection coatings are applied. Transient neural surface displacement is less than 1 nm in amplitude, 1 ms in duration and is coincident with action potential arrival to the optical measurement site. Because the technique uses back-reflected light, noninvasive detection of various neuropathies may be possible.

  15. The implementation of high speed digital PSD in optically pumping magnetometers

    Science.gov (United States)

    Chen, Jun; Cheng, Defu; Zhou, Zhijian; Ma, Ming; Wang, Chao; Hu, Ruifan

    2017-01-01

    The 4He optically pumping magnetometer is a kind of high resolution instrument for measuring magnetic field intensity. Its response speed cannot meet the requirements in some experiments. By analyzing many factors, Phase Sensitive Detector (PSD) which is the key part of the lock-in amplifier processes data at a very slow speed is found. To improve its performance, this paper introduces a parallel digital phase sensitive detector based on coordinate rotation digital computer (CORDIC) algorithm. The cost time of the parallel digital phase sensitive detector is only 5.1% of the previous one. It can greatly enhance the response speed of the 4He optically pumping magnetometer.

  16. Triggers for a high sensitivity charm experiment

    Energy Technology Data Exchange (ETDEWEB)

    Christian, D.C.

    1994-07-01

    Any future charm experiment clearly should implement an E{sub T} trigger and a {mu} trigger. In order to reach the 10{sup 8} reconstructed charm level for hadronic final states, a high quality vertex trigger will almost certainly also be necessary. The best hope for the development of an offline quality vertex trigger lies in further development of the ideas of data-driven processing pioneered by the Nevis/U. Mass. group.

  17. Updating Mars-GRAM to Increase the Accuracy of Sensitivity Studies at Large Optical Depths

    Science.gov (United States)

    Justh, Hiliary L.; Justus, C. G.; Badger, Andrew M.

    2010-01-01

    The Mars Global Reference Atmospheric Model (Mars-GRAM) is an engineering-level atmospheric model widely used for diverse mission applications. Mars-GRAM s perturbation modeling capability is commonly used, in a Monte-Carlo mode, to perform high fidelity engineering end-to-end simulations for entry, descent, and landing (EDL). During the Mars Science Laboratory (MSL) site selection process, it was discovered that Mars-GRAM, when used for sensitivity studies for MapYear=0 and large optical depth values such as tau=3, is less than realistic. From the surface to 80 km altitude, Mars-GRAM is based on the NASA Ames Mars General Circulation Model (MGCM). MGCM results that were used for Mars-GRAM with MapYear set to 0 were from a MGCM run with a fixed value of tau=3 for the entire year at all locations. This has resulted in an imprecise atmospheric density at all altitudes. As a preliminary fix to this pressure-density problem, density factor values were determined for tau=0.3, 1 and 3 that will adjust the input values of MGCM MapYear 0 pressure and density to achieve a better match of Mars-GRAM MapYear 0 with Thermal Emission Spectrometer (TES) observations for MapYears 1 and 2 at comparable dust loading. Currently, these density factors are fixed values for all latitudes and Ls. Results will be presented from work being done to derive better multipliers by including variation with latitude and/or Ls by comparison of MapYear 0 output directly against TES limb data. The addition of these more precise density factors to Mars-GRAM 2005 Release 1.4 will improve the results of the sensitivity studies done for large optical depths.

  18. Mars-GRAM: Increasing the Precision of Sensitivity Studies at Large Optical Depths

    Science.gov (United States)

    Justh, Hilary L.; Justus, C. G.; Badger, Andrew M.

    2010-01-01

    The Mars Global Reference Atmospheric Model (Mars-GRAM) is an engineering-level atmospheric model widely used for diverse mission applications. Mars-GRAM's perturbation modeling capability is commonly used, in a Monte-Carlo mode, to perform high fidelity engineering end-to-end simulations for entry, descent, and landing (EDL). It has been discovered during the Mars Science Laboratory (MSL) site selection process that Mars-GRAM, when used for sensitivity studies for MapYear=0 and large optical depth values such as tau=3, is less than realistic. A comparison study between Mars atmospheric density estimates from Mars-GRAM and measurements by Mars Global Surveyor (MGS) has been undertaken for locations of varying latitudes, Ls, and LTST on Mars. The preliminary results from this study have validated the Thermal Emission Spectrometer (TES) limb data. From the surface to 80 km altitude, Mars-GRAM is based on the NASA Ames Mars General Circulation Model (MGCM). MGCM results that were used for Mars-GRAM with MapYear=0 were from a MGCM run with a fixed value of tau=3 for the entire year at all locations. This has resulted in an imprecise atmospheric density at all altitudes. To solve this pressure-density problem, density factor values were determined for tau=.3, 1 and 3 that will adjust the input values of MGCM MapYear 0 pressure and density to achieve a better match of Mars-GRAM MapYear 0 with TES observations for MapYears 1 and 2 at comparable dust loading. The addition of these density factors to Mars-GRAM will improve the results of the sensitivity studies done for large optical depths.

  19. High-Speed Microscale Optical Tracking Using Digital Frequency-Domain Multiplexing

    OpenAIRE

    MacLachlan, Robert A.; Riviere, Cameron N.

    2009-01-01

    Position-sensitive detectors (PSDs), or lateral-effect photodiodes, are commonly used for high-speed, high-resolution optical position measurement. This paper describes the instrument design for multidimensional position and orientation measurement based on the simultaneous position measurement of multiple modulated sources using frequency-domain-multiplexed (FDM) PSDs. The important advantages of this optical configuration in comparison with laser/mirror combinations are that it has a large ...

  20. High-Speed Microscale Optical Tracking Using Digital Frequency-Domain Multiplexing

    OpenAIRE

    MacLachlan, Robert A.; Riviere, Cameron N.

    2009-01-01

    Position-sensitive detectors (PSDs), or lateral-effect photodiodes, are commonly used for high-speed, high-resolution optical position measurement. This paper describes the instrument design for multidimensional position and orientation measurement based on the simultaneous position measurement of multiple modulated sources using frequency-domain-multiplexed (FDM) PSDs. The important advantages of this optical configuration in comparison with laser/mirror combinations are that it has a large ...

  1. Comparison of sensitivity and resolution load sensor at various configuration polymer optical fiber

    Science.gov (United States)

    Arifin, A.; Yusran, Miftahuddin, Abdullah, Bualkar; Tahir, Dahlang

    2017-01-01

    This study uses a load sensor with a macro-bending on polymer optical fiber loop model which is placed between two plates with a buffer spring. The load sensor with light intensity modulation principle is an infrared LED emits light through the polymer optical fiber then received by the phototransistor and amplifier. Output voltage from the amplifier continued to arduino sequence and displayed on the computer. Load augment on the sensor resulted in an increase of curvature on polymer optical fibers that can cause power losses gets bigger too. This matter will result in the intensity of light that received by phototransistor getting smaller, so that the output voltage that ligable on computer will be getting smaller too. The sensitivity and resolution load sensors analyzed based on configuration with various amount of loops, imperfection on the jacket, and imperfection at the cladding and core of polymer optical fiber. The results showed that the augment on the amount of load, imperfection on the jacket and imperfection on the sheath and core polymer optical fiber can improve the sensitivity and resolution of the load sensor. The best sensors resolution obtained on the number of loops 4 with imperfection 8 on the core and cladding polymer optical fiber that is 0.037 V/N and 0,026 N. The advantages of the load sensor based on polymers optical fiber are easy to make, low cost and simple to use measurement methods.

  2. A Sensitive Scheme to Observe Weak Photo-Refraction Effects in Some Nonlinear Optical Crystals Pumped by Ultrashort Optical Pulses

    Institute of Scientific and Technical Information of China (English)

    XU Shi-Xiang; GAO Yan-Xia; CAI Hua; LI Jing-Zhen

    2009-01-01

    We present a sensitive scheme, for the first time to our knowledge, to observe photo-refraction (PR) effects in some nonlinear optical crystals, e.g.β-BBO, LBO and BIBO, pumped by an intense ultrashort laser pulse chain. These quite weak effects are "amplified" by sensitive cw intracavity loss modulation. Our results show that they are repeatable and are dependent on pumping power and wavelength, and their response time ranges from tens of seconds to several minutes. The recorded dynamical transitions between the self-focusing to the self-defocusing (or vice versa) induced by the PR effect may be critically important for us to give more insight into the stability of some cascade nonlinear frequency conversions, e.g. multi-stage optical parametric amplifiers.

  3. Highly stable piezoelectrically tunable optical cavities

    CERN Document Server

    Möhle, Katharina; Döringshoff, Klaus; Nagel, Moritz; Peters, Achim

    2013-01-01

    We have implemented highly stable and tunable frequency references using optical high finesse cavities which incorporate a piezo actuator. As piezo material we used ceramic PZT, crystalline quartz, or PZN-PT single crystals. Lasers locked to these cavities show a relative frequency stability better than 1 x 10^{-14}, which is most likely not limited by the piezo actuators. The piezo cavities can be electrically tuned over more than one free spectral range (> 1.5 GHz) with only a minor decrease in frequency stability. Furthermore, we present a novel cavity design, where the piezo actuator is prestressed between the cavity spacer components. This design features a hermetically sealable intra cavity volume suitable for, e.g., cavity enhanced spectroscopy.

  4. Fiber optic chemical sensors: The evolution of high- density fiber-optic DNA microarrays

    Science.gov (United States)

    Ferguson, Jane A.

    2001-06-01

    Sensors were developed for multianalyte monitoring, fermentation monitoring, lactate analysis, remote oxygen detection for use in bioremediation monitoring and in a fuel spill clean-up project, heavy metal analysis, and high density DNA microarrays. The major focus of this thesis involved creating and improving high-density DNA gene arrays. Fiber optic sensors are created using fluorescent indicators, polymeric supports, and optical fiber substrates. The fluorescent indicator is entrapped in a polymer layer and attached to the tip of the optical fiber. The tip of the fiber bearing the sensing layer (the distal end) is placed in the sample of interest while the other end of the fiber (the proximal end) is connected to an analysis system. Any length of fiber can be used without compromising the integrity or sensitivity of the system. A fiber optic oxygen sensor was designed incorporating an oxygen sensitive fluorescent dye and a gas permeable polymer attached to an optical fiber. The construction simplicity and ruggedness of the sensor enabled its deployment for in situ chemical oxidation and bioremediation studies. Optical fibers were also used as the substrate to detect biomolecules in solution. To monitor bioprocesses, the production of the analyte of interest must be coupled with a species that is optically measurable. For example, oxygen is consumed in many metabolic functions. The fiber optic oxygen sensor is equipped with an additional sensing layer. Upon contact with a specific biochemical in the sample, a reaction occurs in the additional sensing layer that either consumes or produces oxygen. This dual layer system was used to monitor the presence of lactate, an important metabolite for clinical and bioprocess analysis. In many biological and environmental systems, the generation of one species occurs coincidentally with the generation or consumption of another species. A multianalyte sensor was prepared that can monitor the simultaneous activity of pH, CO2

  5. Scalloped electrodes for highly sensitive electrical measurements

    DEFF Research Database (Denmark)

    Vazquez Rodriguez, Patricia; Dimaki, Maria; Svendsen, Winnie Edith

    2011-01-01

    In this work we introduce a novel out-of-plane electrode with pronounced scalloped surface and high aspect ratio for electrical recordings of brain tissue in vitro, with the aim to reduce significantly the impedance of the measuring system. The profile and height of the structures is tailored...... by means of silicon fabrication techniques that sharpen them progressively and in a controlled manner. We will show that the use of the scalloped area achieves a great decrease in impedance, which is very significant for a reduction of noise in electrical measurements. The measured impedance reflects...

  6. Method for high-speed Manchester encoded optical signal generation

    DEFF Research Database (Denmark)

    Zhang, Jianfeng; Chi, Nan; Holm-Nielsen, Pablo Villanueva

    2004-01-01

    A method for high-speed Manchester encoded optical signal generation is proposed and demonstrated with a specially configured electro-optical modulator. A 10 Gb/s Manchester encoded optical signal was generated, and its bit-error-ratio (BER) performance was evaluated.......A method for high-speed Manchester encoded optical signal generation is proposed and demonstrated with a specially configured electro-optical modulator. A 10 Gb/s Manchester encoded optical signal was generated, and its bit-error-ratio (BER) performance was evaluated....

  7. High quality factor and high sensitivity chalcogenide 1D photonic crystal microbridge cavity for mid-infrared sensing

    Science.gov (United States)

    Xu, Peipeng; Yu, Zenghui; Shen, Xiang; Dai, Shixun

    2017-01-01

    We present and theoretically investigate a mid-infrared (mid-IR) optical sensor based on a Ge11.5As24Se64.5 one-dimensional photonic crystal microbridge cavity (PhC-MC). Optimizing the structure of the PhC-MC strongly confines the resonant mode field to the air region, thereby greatly enhancing the overlap and interaction of the light field and target analytes. A high calculated sensitivity (2280 nm per refractive index unit) is achieved with a resonant wavelength of 4132 nm. The figure of merit of the device for sensing is extremely high (929,750) because of the high quality factor and sensitivity of the cavity. The sensing part of the cavity is also small (50×3 μm2). The proposed PhC-MC can be an ideal platform for on-chip integrated mid-IR optical sensing.

  8. High pressure fiber optic sensor system

    Science.gov (United States)

    Guida, Renato; Xia, Hua; Lee, Boon K; Dekate, Sachin N

    2013-11-26

    The present application provides a fiber optic sensor system. The fiber optic sensor system may include a small diameter bellows, a large diameter bellows, and a fiber optic pressure sensor attached to the small diameter bellows. Contraction of the large diameter bellows under an applied pressure may cause the small diameter bellows to expand such that the fiber optic pressure sensor may measure the applied pressure.

  9. Multipurpose High Sensitivity Radiation Detector: Terradex

    Energy Technology Data Exchange (ETDEWEB)

    Alpat, Behcet [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy)]. E-mail: behcet.alpat@pg.infn.it; Aisa, Damiano [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Bizzarri, Marco [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Blasko, Sandor [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Esposito, Gennaro [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Farnesini, Lucio [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Fiori, Emmanuel [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Papi, Andrea [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Postolache, Vasile [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Renzi, Francesca [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Ionica, Romeo [Politecnica University of Bucarest, Splaiul Indipendentei, Bucharest (Romania); Manolescu, Florentina [Space Science Institute of Bucharest, Maugurele, Bucharest (Romania); Ozkorucuklu, Suat [Suleyman Demirel Universitesi, Isparta (Turkey); Denizli, Haluk [Abant Izzet Baysal Universitesi, Bolu (Turkey); Tapan, Ilhan [Uludag Universitesi, Bursa (Turkey); Ercan Pilicer [Uludag Universitesi, Bursa (Turkey); Egidi, Felice [SITE Technology, Carsoli (Italy); Moretti, Cesare [SITE Technology, Carsoli(AQ) (Italy); Dicola, Luca [SITE Technology, Carsoli(AQ) (Italy)

    2007-05-11

    Terradex project aims to realise an accurate and programmable multiparametric tool which will measure relevant physical quantities such as observation time, energy and type of all decay products of three naturally occurring decay chains of uranium and thorium series present in nature as well as the decay products of man-made radioactivity. The measurements described in this work are based on the performance tests of the first version of an instrument that is designed to provide high counting accuracy, by introducing self-triggering, delayed time-coincidence technique, of products of a given decay chain. In order to qualify the technique and to calibrate the Terradex, a {sup 222}Rn source is used. The continuous and accurate monitoring of radon concentration in air is realised by observing the alpha and beta particles produced by the decay of {sup 222}Rn and its daughters and tag each of them with a precise occurrence time. The validity of delayed coincident technique by using the state of the art electronics with application of novel data sampling and analysis methods are discussed. The flexibility of sampling protocols and the advantages of online calibration capability to achieve the highest level of precision in natural and man-made radiation measurements are also described.

  10. Phase-sensitive microwave optical double resonance in an N system

    Science.gov (United States)

    Preethi, T. M.; Manukumara, M.; Asha, K.; Vijay, J.; Roshi, D. A.; Narayanan, A.

    2011-08-01

    An experimental investigation of a Microwave Optical Double Resonance (MODR) phenomenon is carried out in a four level N system of 85Rb atoms, at room temperature. This N system consists of a closed three level Λ subsystem irradiated with two optical fields and one microwave field. The MODR response is investigated in a separate probe field which drives a resonant transition from one of the ground states of the Λ system to a fourth level. We find that, under two-photon resonance condition for the optical fields, the MODR becomes a function of the relative phase between the beat frequency envelop of the optical fields and the microwave field. The variation in MODR is shown to be correlated with the phase-sensitive variation of the EIT phenomenon seen in such microwave-connected closed Λ systems. We envisage that this phase-sensitive variation in the MODR, can be utilized for a phase-sensitive manipulation of non-linear optical phenomena in N systems.

  11. Surface enhanced Raman optical activity as an ultra sensitive tool for ligand binding analysis

    DEFF Research Database (Denmark)

    Johannessen, Christian; Abdali, Salim

    2007-01-01

    The Surface Enhanced Resonance Raman Scattering (SERRS) and Surface Enhanced Resonance Raman Optical Activity (SERROA) spectra of myoglobin and the myoglobin-azide complex were measured on very dilute samples (100 nM protein) in order to analyze the sensitivity of SERROA spectroscopy when inducing...

  12. Macular sensitivity and fixation patterns in patients with autosomal dominant optic atrophy

    DEFF Research Database (Denmark)

    Rönnbäck, Cecilia; Larsen, Michael

    2014-01-01

    INTRODUCTION: The objective of this study was to test macular sensitivity, fixation stability and fixation location using microperimetry in patients with autosomal dominant optic atrophy (ADOA) and mutation-free relatives. MATERIAL AND METHODS: This was a cross-sectional study of 43 patients...

  13. 16 channel WDM regeneration in a single phase-sensitive amplifier through optical Fourier transformation

    DEFF Research Database (Denmark)

    Guan, Pengyu; Da Ros, Francesco; Lillieholm, Mads

    2016-01-01

    We demonstrate simultaneous phase regeneration of 16-WDM DPSK channels using optical Fourier transformation and a single phase-sensitive amplifier. The BERs of 16-WDM×10-Gbit/s phase noise degraded DPSK signals are improved by 0.4-1.3 orders of magnitude...

  14. Sensitivity calibration procedures in optical-CT scanning of BANG 3 polymer gel dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Y.; Wuu, Cheng-Shie; Maryanski, Marek J. [Department of Radiation Oncology, Columbia University, New York, New York 10032 (United States); Department of Radiation Oncology, Columbia University, New York, New York 10032 and MGS Research Inc., Madison, Connecticut 06443 (United States)

    2010-02-15

    The dose response of the BANG 3 polymer gel dosimeter (MGS Research Inc., Madison, CT) was studied using the OCTOPUS laser CT scanner (MGS Research Inc., Madison, CT). Six 17 cm diameter and 12 cm high Barex cylinders, and 18 small glass vials were used to house the gel. The gel phantoms were irradiated with 6 and 10 MV photons, as well as 12 and 16 MeV electrons using a Varian Clinac 2100EX. Three calibration methods were used to obtain the dose response curves: (a) Optical density measurements on the 18 glass vials irradiated with graded doses from 0 to 4 Gy using 6 or 10 MV large field irradiations; (b) optical-CT scanning of Barex cylinders irradiated with graded doses (0.5, 1, 1.5, and 2 Gy) from four adjacent 4x4 cm{sup 2} photon fields or 6x6 cm{sup 2} electron fields; and (c) percent depth dose (PDD) comparison of optical-CT scans with ion chamber measurements for 6x6 cm{sup 2}, 12 and 16 MeV electron fields. The dose response of the BANG 3 gel was found to be linear and energy independent within the uncertainties of the experimental methods (about 3%). The slopes of the linearly fitted dose response curves (dose sensitivities) from the four field irradiations (0.0752{+-}3%, 0.0756{+-}3%, 0.0767{+-}3%, and 0.0759{+-}3% cm{sup -1} Gy{sup -1}) and the PDD matching methods (0.0768{+-}3% and 0.0761{+-}3% cm{sup -1} Gy{sup -1}) agree within 2.2%, indicating a good reproducibility of the gel dose response within phantoms of the same geometry. The dose sensitivities from the glass vial approach are different from those of the cylindrical Barex phantoms by more than 30%, owing probably to the difference in temperature inside the two types of phantoms during gel formation and irradiation, and possible oxygen contamination of the glass vial walls. The dose response curve obtained from the PDD matching approach with 16 MeV electron field was used to calibrate the gel phantom irradiated with the 12 MeV, 6x6 cm{sup 2} electron field. Three-dimensional dose distributions

  15. Read-only high accuracy volume holographic optical correlator

    Science.gov (United States)

    Zhao, Tian; Li, Jingming; Cao, Liangcai; He, Qingsheng; Jin, Guofan

    2011-10-01

    A read-only volume holographic correlator (VHC) is proposed. After the recording of all of the correlation database pages by angular multiplexing, a stand-alone read-only high accuracy VHC will be separated from the VHC recording facilities which include the high-power laser and the angular multiplexing system. The stand-alone VHC has its own low power readout laser and very compact and simple structure. Since there are two lasers that are employed for recording and readout, respectively, the optical alignment tolerance of the laser illumination on the SLM is very sensitive. The twodimensional angular tolerance is analyzed based on the theoretical model of the volume holographic correlator. The experimental demonstration of the proposed read-only VHC is introduced and discussed.

  16. Sensitivity Study of Ice Crystal Optical Properties in the 874 GHz Submillimeter Band

    Science.gov (United States)

    Tang, Guanglin; Yang, Ping; Wu, Dong L.

    2015-01-01

    Testing of an 874 GHz submillimeter radiometer on meteorological satellites is being planned to improve ice water content retrievals. In this paper we study the optical properties of ice cloud particles in the 874 GHz band. The results show that the bulk scattering and absorption coefficients of an ensemble of ice cloud particles are sensitive to the particle shape and effective diameter, whereas the latter is also sensitive to temperature. The co-polar back scattering cross-section is not sensitive to particle shape, temperature, and the effective diameter in the range of 50200 m.

  17. High nonlinear optical anisotropy of urea nanofibers

    Science.gov (United States)

    Isakov, D.; de Matos Gomes, E.; Belsley, M.; Almeida, B.; Martins, A.; Neves, N.; Reis, R.

    2010-07-01

    Nanofibers consisting of the optically nonlinear organic molecule urea embedded in both poly(ethylene oxide) (PEO) and poly(vinyl alcohol) (PVA) polymers were produced by the electrospinning technique. The second-harmonic generation produced by aligned fiber mats of these materials displays a strong dependence on the polarization of the incident light. In PVA-urea nanofibers the effectiveness in generating of the second-harmonic light is as high as that of a pure urea powder with an average grain size of 110 μm. The results suggest that single crystalline urea nanofibers were achieved with a long-range crystalline order extending into the range of 2-4 μm with PVA as the host polymer.

  18. In vitro birefringence imaging with spectral domain polarization-sensitive optical coherence tomography

    Institute of Scientific and Technical Information of China (English)

    Qiang Gong; Chuanmao Fan; Fan Zhang; Jianquan Yao

    2008-01-01

    Spectral domain polarization-sensitive optical coherence tomography (SDPS-OCT) is a depth-resolved polarization-sensitive interferometry which integrates polarization optics into spectral domain optical co-herence tomography (SD-OCT). This configuration can obtain birefringence information of samples and improve the imaging speed. In this paper, horizontally polarized light is used to replace natural light of the source. Then, right-rotated circularly polarized light is the incident sample light. To obtain two orthogonal components of the polarized interferogram, the reflected light of the reference arm is set to be 45° linearly polarized light. These two components are acquired by two spectrometers synchronously. The system was employed to achieve 12.8-#m axial resolution and 4.36-#m transverse resolution. We have imaged in vitro chicken tendon and muscle tissues with these system.

  19. High temperature probe sensor with high sensitivity based on Michelson interferometer

    Science.gov (United States)

    Zhao, Na; Fu, Haiwei; Shao, Min; Yan, Xu; Li, Huidong; Liu, Qinpeng; Gao, Hong; Liu, Yinggang; Qiao, Xueguang

    2015-05-01

    A novel Michelson interferometer based on a bi-taper is achieved. Such a device is fabricated by splicing a section of thin core fiber (TCF) at one end of single-mode fiber (SMF). Due to the fiber bi-taper at the splicing point of SMF and TCF, the light is coupled into the fiber core and cladding from lead in fiber core. The light will be reflected at the end of the fiber and then will be recoupled back into the lead out fiber core by the fiber bi-taper. While the light returns back to the lead out fiber, the intermodal interference will occur for the optical path difference between core mode and cladding mode. A high temperature sensitivity of 0.140 nm/°C is achieved from 30 to 800 °C, and the linearity is 99.9%. The configuration features the advantages of easy fabrication, a compact size, high sensitivity, wide sensing range and high mechanical strength, making it a good candidate for distant temperature sensing and oil prospecting.

  20. Highly sensitive ammonia sensor using reflection of light at a glass - photonic crystal interface

    CERN Document Server

    Kuchyanov, A S; Spisser, H; Plekhanov, A I

    2013-01-01

    We have discovered and studied the effect of the asymmetric deformation of a photonic crystal in the form of a change in the slope of the crystal planes as it is filled with a gaseous analyte. We have demonstrated that the use of a new effect leading to the displacement of the stop band against the unchanged spectrum of diffracted white light at the (glass-thin opal film) interface can be used as fast, compact, high sensitive and reproducible optical chemical sensor for ammonia. Low cost and simplicity of sensor fabrication, the response of which can be easily observed without resorting to spectral instruments are therefore likely to be attractive. The basis for high sensitivity (1 ppm), fast response (120 ms) is capillary vapor condensation. On the basis of this effect a cheap high-speed and highly sensitive gas sensors has been built.

  1. Design optimization of high pressure and high temperature piezoresistive pressure sensor for high sensitivity

    Science.gov (United States)

    Niu, Zhe; Zhao, Yulong; Tian, Bian

    2014-01-01

    This paper describes a design method for optimizing sensitivity of piezoresistive pressure sensor in high-pressure and high-temperature environment. In order to prove the method, a piezoresistive pressure sensor (HPTSS) is designed. With the purpose of increasing sensitivity and to improve the measurement range, the piezoresistive sensor adopts rectangular membrane and thick film structure. The configuration of piezoresistors is arranged according to the characteristic of the rectangular membrane. The structure and configuration of the sensor chip are analyzed theoretically and simulated by the finite element method. This design enables the sensor chip to operate in high pressure condition (such as 150 MPa) with a high sensitivity and accuracy. The silicon on insulator wafer is selected to guarantee the thermo stability of the sensor chip. In order to optimize the fabrication and improve the yield of production, an electric conduction step is devised. Series of experiments demonstrates a favorable linearity of 0.13% and a high accuracy of 0.48%. And the sensitivity of HTPSS is about six times as high as a conventional square-membrane sensor chip in the experiment. Compared with the square-membrane pressure sensor and current production, the strength of HPTTS lies in sensitivity and measurement. The performance of the HPTSS indicates that it could be an ideal candidate for high-pressure and high-temperature sensing in real application.

  2. Design optimization of high pressure and high temperature piezoresistive pressure sensor for high sensitivity.

    Science.gov (United States)

    Niu, Zhe; Zhao, Yulong; Tian, Bian

    2014-01-01

    This paper describes a design method for optimizing sensitivity of piezoresistive pressure sensor in high-pressure and high-temperature environment. In order to prove the method, a piezoresistive pressure sensor (HPTSS) is designed. With the purpose of increasing sensitivity and to improve the measurement range, the piezoresistive sensor adopts rectangular membrane and thick film structure. The configuration of piezoresistors is arranged according to the characteristic of the rectangular membrane. The structure and configuration of the sensor chip are analyzed theoretically and simulated by the finite element method. This design enables the sensor chip to operate in high pressure condition (such as 150 MPa) with a high sensitivity and accuracy. The silicon on insulator wafer is selected to guarantee the thermo stability of the sensor chip. In order to optimize the fabrication and improve the yield of production, an electric conduction step is devised. Series of experiments demonstrates a favorable linearity of 0.13% and a high accuracy of 0.48%. And the sensitivity of HTPSS is about six times as high as a conventional square-membrane sensor chip in the experiment. Compared with the square-membrane pressure sensor and current production, the strength of HPTTS lies in sensitivity and measurement. The performance of the HPTSS indicates that it could be an ideal candidate for high-pressure and high-temperature sensing in real application.

  3. Automated identification of basal cell carcinoma by polarization-sensitive optical coherence tomography

    Science.gov (United States)

    Duan, Lian; Marvdashti, Tahereh; Lee, Alex; Tang, Jean Y.; Ellerbee, Audrey K.

    2014-01-01

    We report an automated classifier to detect the presence of basal cell carcinoma in images of mouse skin tissue samples acquired by polarization-sensitive optical coherence tomography (PS-OCT). The sensitivity and specificity of the classifier based on combined information of the scattering intensity and birefringence properties of the samples are significantly higher than when intensity or birefringence information are used alone. The combined information offers a sensitivity of 94.4% and specificity of 92.5%, compared to 78.2% and 82.2% for intensity-only information and 85.5% and 87.9% for birefringence-only information. These results demonstrate that analysis of the combination of complementary optical information obtained by PS-OCT has great potential for accurate skin cancer diagnosis. PMID:25360384

  4. Thermal lensing compensation principle for the ACIGA's High Optical Power Test Facility Test 1

    Science.gov (United States)

    Degallaix, Jérřome; Slagmolen, Bram; Zhao, Chunnong; Ju, Li; Blair, David

    2005-09-01

    Thermal lensing is becoming recognized as one of the dominant obstacles to the second generation of laser interferometric gravitational wave detectors. Very high optical power is required to circulate in the interferometer to reach the sensitivity goal, creating strong thermal induced wavefront distortion. These effects will be studied at the High Optical Power Test Facility in Gingin, Western Australia. In this paper, we present simulation results for the first test planned for the middle of 2004. This experiment will produce 5 kW of optical power circulating inside a Fabry Perot cavity and will demonstrate large thermal lensing effects.

  5. A highly sensitive colorimetric and ratiometric sensor for fluoride ion

    Institute of Scientific and Technical Information of China (English)

    Zhao Wu Xu; Jin Tang; He Tian

    2008-01-01

    A new benzoimidazole-naphthalimide derivative 4 was synthesized and its photophysical properties were studied.This compound showed highly selectively and sensitive colorimetric and ratiometric sensing ability for fluoride anion.

  6. All-Optical Temporal Differentiator Using a High Resolution Optical Arbitrary Waveform Shaper

    Institute of Scientific and Technical Information of China (English)

    DONG Jian-Ji; LUO Bo-Wen; ZHANG Yin; LEI Lei; HUANG De-Xiu; ZHANG Xin-Liang

    2012-01-01

    We experimentally demonstrate an all-optical temporal differentiator using a high resolution optical arbitrary waveform shaper, which is based on liquid crystal on silicon switching elements, and both amplitude and phase of the spectrum are programmable. By designing specific transfer functions with the optical waveform shaper, we obtain first-, second-, and third-order differentiators for periodic pulses with small average errors. We also theoretically analyze the bandwidth limitation of optical waveform shaper on the differentiator.%We experimentally demonstrate an all-optical temporal differentiator using a high resolution optical arbitrary waveform shaper,which is based on liquid crystal on silicon switching elements,and both amplitude and phase of the spectrum are programmable.By designing specific transfer functions with the optical waveform shaper,we obtain first-,second-,and third-order differentiators for periodic pulses with small average errors.We also theoretically analyze the bandwidth limitation of optical waveform shaper on the differentiator.

  7. Crystal optics for hard-X-ray spectroscopy of highly charged ions

    OpenAIRE

    Beyer, H. F.; Attia, D.; Banas, D; Bigot, E. -O. Le; Bosch, F.; Dousse, Jean-Claude; Förster, E.; Gumberidze, A.; Hagmann, S.; Heß, S.; J. Hoszowska; Indelicato, P.; Jagodzinski, P.; Kozhuharov, Chr.; Krings, Th.

    2009-01-01

    A twin crystal-spectrometer assembly, operated in the focusing compensated asymmetric Laue geometry has been developed for accurate spectroscopy of fast highly charged heavy ions in the hard-X-ray region. Coupled to the focusing crystal optics is a specially developed two-dimensional position-sensitive X-ray detector which is necessary for retaining spectral resolution also for fast moving sources. We summarize the crystal optics and demonstrate the usefulness of the instrument for spectrosco...

  8. Sensitivity of aerosol optical thickness and aerosol direct radiative effect to relative humidity

    Directory of Open Access Journals (Sweden)

    H. Bian

    2008-07-01

    Full Text Available We present a sensitivity study on the effects of spatial and temporal resolution of atmospheric relative humidity (RH on calculated aerosol optical thickness (AOT and the aerosol direct radiative effects (DRE in a global model. Using the same aerosol fields simulated in the Global Modeling Initiative (GMI model, we find that, on a global average, the calculated AOT from RH in 1° latitude by 1.25° longitude spatial resolution is 11% higher than that in 2° by 2.5° resolution, and the corresponding DRE at the top of the atmosphere is 8–9% higher for total aerosols and 15% higher for only anthropogenic aerosols in the finer spatial resolution case. The difference is largest over surface escarpment regions (e.g. >200% over the Andes Mountains where RH varies substantially with surface terrain. The largest zonal mean AOT difference occurs at 50–60°N (16–21%, where AOT is also relatively larger. A similar increase is also found when the time resolution of RH is increased. This increase of AOT and DRE with the increase of model resolution is due to the highly non-linear relationship between RH and the aerosol mass extinction efficiency (MEE at high RH (>80%. Our study suggests that caution should be taken in a multi-model comparison (e.g. AeroCom since the comparison usually deals with results coming from different spatial/temporal resolutions.

  9. High sensitivity, wide coverage, and high-resolution NIR non-cryogenic spectrograph, WINERED

    Science.gov (United States)

    Ikeda, Yuji; Kobayashi, Naoto; Kondo, Sohei; Otsubo, Shogo; Hamano, Satoshi; Sameshima, Hiroaki; Yoshikawa, Tomoshiro; Fukue, Kei; Nakanishi, Kenshi; Kawanishi, Takafumi; Nakaoka, Tetsuya; Kinoshita, Masaomi; Kitano, Ayaka; Asano, Akira; Takenaka, Keiichi; Watase, Ayaka; Mito, Hiroyuki; Yasui, Chikako; Minami, Atsushi; Izumu, Natsuko; Yamamoto, Ryo; Mizumoto, Misaki; Arasaki, Takayuki; Arai, Akira; Matsunaga, Noriyuki; Kawakita, Hideyo

    2016-08-01

    Near-infrared (NIR) high-resolution spectroscopy is a fundamental observational method in astronomy. It provides significant information on the kinematics, the magnetic fields, and the chemical abundances, of astronomical objects embedded in or behind the highly extinctive clouds or at the cosmological distances. Scientific requirements have accelerated the development of the technology required for NIR high resolution spectrographs using 10 m telescopes. WINERED is a near-infrared (NIR) high-resolution spectrograph that is currently mounted on the 1.3 m Araki telescope of the Koyama Astronomical Observatory in Kyoto-Sangyo University, Japan, and has been successfully operated for three years. It covers a wide wavelength range from 0.90 to 1.35 μm (the z-, Y-, and J-bands) with a spectral resolution of R = 28,000 (Wide-mode) and R = 80,000 (Hires-Y and Hires-J modes). WINERED has three distinctive features: (i) optics with no cold stop, (ii) wide spectral coverage, and (iii) high sensitivity. The first feature, originating from the Joyce proposal, was first achieved by WINERED, with a short cutoff infrared array, cold baffles, and custom-made thermal blocking filters, and resulted in reducing the time for development, alignment, and maintenance, as well as the total cost. The second feature is realized with the spectral coverage of Δλ/λ 1/6 in a single exposure. This wide coverage is realized by a combination of a decent optical design with a cross-dispersed echelle and a large format array (2k x 2k HAWAII- 2RG). The Third feature, high sensitivity, is achieved via the high-throughput optics (>60 %) and the very low noise of the system. The major factors affecting the high throughput are the echelle grating and the VPH cross-disperser with high diffraction efficiencies of 83 % and 86 %, respectively, and the high QE of HAWAII-2RG (83 % at 1.23 μm). The readout noise of the electronics and the ambient thermal background radiation at longer wavelengths could be

  10. Optical sampling of ultrahigh bitrate signals using highly nonlinear chalcogenide planar waveguides or tapered fibers

    Science.gov (United States)

    Van Erps, Jürgen; Luan, Feng; Pelusi, Mark D.; Mägi, Eric; Iredale, Tim; Madden, Steve; Choi, Duk Yong; Bulla, Douglas A.; Luther-Davies, Barry; Thienpont, Hugo; Eggleton, Benjamin J.

    2010-06-01

    As the bit rates of optical networks increase, the ability of accurate monitoring of optical waveforms has become increasingly important. In recent years, optical sampling has emerged as a technique to perform time-resolved measurements of optical data signals at high data rates with a bandwidth that cannot be reached by conventional photodetectors and oscilloscopes. In an optical sampling system, the optical signal is sampled in the optical domain by a nonlinear optical sampling gate before the resulting samples are converted to an electrical signal. This avoids the need for high bandwidth electronics if the optical sampling gate is operated with a modest repetition frequency. In this paper, we present an optical sampling system using the optical Kerr effect in a highly nonlinear chalcogenide device, enabling combined capability for femtosecond resolution and broadband signal wavelength tunability. A temporal resolution 450-fs is achieved using four-wave mixing (FWM) in dispersion-engineered chalcogenide waveguides: on one hand a 7-cm long planar waveguide (integrated on a photonic chip) and on the other hand a 5-cm long tapered fiber. The use of a short length, dispersion-shifted waveguide with ultrahigh nonlinearity (10000/W/km) enables high-resolution optical sampling without the detrimental effect of chromatic dispersion on the temporal distortion of the signal and sampling pulses, as well as their phase mismatch (which in turn would degrade the FWM efficiency and the sensitivity of the measurement). Using these chalcogenide devices, we successfully monitor a 640-Gb/s optical time-division multiplexing (OTDM) datastream, showcasing its potential for monitoring of signals at bitrates approaching and beyond Tb/s. We compare the advantages and disadvantages of both approaches and discuss fundamental limitations as well as potential improvements.

  11. The design of space optical communications terminal with high efficient

    Science.gov (United States)

    Deng, Xiaoguo; Li, Gang; Jiang, Bo; Yang, Xiaoxu; Yan, Peipei

    2015-02-01

    In order to improve high-speed laser space optical communications terminal receive energy and emission energy, meet the demand of mini-type and light-type for space-based bear platform, based on multiple-reflect coaxial optical receiving antenna structure, while considering the installation difficulty, a high-efficient optical system had been designed, which aperture is off-axial, both signal-receiving sub-optical system and emission sub-optical system share a same primary optical path. By the separating light lens behind the primary optical path, the received light with little energy will be filtered and shaped and then transmitted to each detector, at the same time, by the coupling element, the high-power laser will be coupling into optical antenna, and then emitted to outside. Applied the power-detected optical system evaluate principle, the optimized off-axial optical system's efficiency had been compared with the coaxial optical system. While, analyzed the Gauss beam energy distribution by numerical theory, discussed that whether off-axis optical system can be an emission terminal, verify the feasibility of the theory of the design of the system.

  12. Optical micromachined ultrasound transducers (OMUT) - a new approach for high resolution imaging

    Science.gov (United States)

    Tadayon, M. A.; Ashkenazi, S.

    2013-03-01

    Piezoelectric ultrasound (US) transducers are at the heart of almost any ultrasonic medical imaging probe. However, their sensitivity and reliability severely degrade in applications requiring high frequency (>20 MHz) and small element size (construct micron-size air cavities capped by an elastic membrane. The membrane functions as the active ultrasound transmitter and receiver. We will describe the design and testing of prototype OMUT devices which implement a receive-only function. The cavity detector is an optical cavity which its top mirror is deflected under the application of pressure. The intensity of a reflected light beam is highly sensitive to displacement of the top membrane if the optical wavelength is at near-resonance condition. Therefore, US pulses can be detected by recording the reflected light intensity. The sensitivity of the device depends on the mechanical properties of the top membrane and optical characteristics of the optical cavity. The device was fabricated using SU8 as a structural material and gold as a mirror. We have developed a new bonding method to fabricate a sealed, low roughness, high quality optical cavity. The 60μm cavity with the 8.5 μm top membrane is tested in water with 25MHz ultrasound transducer. The NEP of the device for bandwidth of 28MHz was 9.25kPa. The optical cavity has a finesse of around 23.

  13. Polarization-sensitive swept-source optical coherence tomography with continuous source polarization modulation

    OpenAIRE

    Yamanari, Masahiro; Makita, Shuichi; Yasuno, Yoshiaki

    2008-01-01

    We present fiber-based polarization-sensitive swept-source optical coherence tomography (SS-OCT) based on continuous source polarization modulation. The light source is a frequency swept laser centered at 1.31 μm with a scanning rate of 20 kHz. The incident polarization is modulated by a resonant electro-optic modulator at 33.3 MHz, which is one-third of the data acquisition frequency. The zeroth- and first-order harmonic components of the OCT signals with respect to the polarization modulati...

  14. Towards Extremely Sensitive Ultraviolet-Light Sensors Employing Photochromic Optical Microfiber

    Directory of Open Access Journals (Sweden)

    George Y. Chen

    2015-01-01

    Full Text Available We propose an extremely responsive ultraviolet-light sensor (−1.39 × 106 dB/(W/cm2 based on photochromic optical microfiber. A densely packed planar coil of ZBLAN optical microfiber is doped with photochromic dyes. Under ultraviolet radiation, the photochromic microfiber experiences temporary photodarkening, and the change in the transmission of the probe light provides a measure of the incident ultraviolet light. This novel design grants an enhancement in sensitivity (3.13 nW/cm2 by at least one order of magnitude compared to traditional electrical counterparts.

  15. Optical Transmitter Terminal for Selective RF High Frequency Bans Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the proposal work is to investigate the highly innovative conceptual design of an optical communication selective frequency transmitter terminal...

  16. Highly Sensitive Cadmium Concentration Sensor Using Long Period Grating

    Directory of Open Access Journals (Sweden)

    A. S. Lalasangi

    2011-08-01

    Full Text Available In this paper we have proposed a simple and effective Long Period Grating chemical sensor for detecting the traces of Cadmium (Cd++ in drinking water at ppm level. Long Period gratings (LPG were fabricated by point-by-point technique with CO2 laser. We have characterized the LPG concentration sensor sensitivity for different solutions of Cd concentrations varying from 0.01 ppm to 0.04 ppm by injecting white Light source and observed transmitted spectra using Optical Spectrum Analyzer (OSA. Proper reagents have been used in the solutions for detection of the Cd species. The overall shift in wavelength is 10 nm when surrounding medium gradually changed from water to 0.04 ppm of cadmium concentrations. A comparative study has been done using sophisticated spectroscopic atomic absorption spectrometer (AAS and Inductively Coupled Plasma (ICP instruments. The spectral sensitivity enhancement was done by modifying grating surface with gold nanoparticles.

  17. TOCUSO: Test of Conceptual Understanding on High School Optics Topics

    Science.gov (United States)

    Akarsu, Bayram

    2012-01-01

    Physics educators around the world often need reliable diagnostic materials to measure students' understanding of physics concept in high school. The purpose of this study is to evaluate a new diagnostic tool on High School Optics concept. Test of Conceptual Understanding on High School Optics (TOCUSO) consists of 25 conceptual items that…

  18. Transplantation in highly HLA-sensitized patients: challenges and solutions

    Directory of Open Access Journals (Sweden)

    Kim IK

    2014-09-01

    Full Text Available Irene K Kim, Ashley Vo, Stanley C Jordan Transplant Immunotherapy Program, Comprehensive Transplant Center, Cedars-Sinai Medical Center, Los Angeles, CA, USA Abstract: Despite better understanding of the impact of development of the human leukocyte antigen (HLA antibody and numerous advancements in immunosuppressive therapy, the ability to successfully transplant highly sensitized patients remains a significant challenge. As the percentage of the waiting list becomes increasingly populated with highly sensitized patients, there is a growing demand for effective strategies to manage these patients. Over the past 20 years, desensitization therapies have been modified and developed, and are mainly utilized at transplant centers that have developed expertise. In addition, recognition that the highly sensitized patient population is disadvantaged on the transplant waiting list has led to recent changes in national kidney allocation policy. Furthermore, creative strategies, such as enrollment of sensitized patients into paired kidney exchange programs, have been developed to find compatible matches for these patients. The goal of this article is to address some of the specific challenges related to transplanting the highly sensitized patient at a high-volume transplant center with experience in desensitization and to review established and emerging solutions to help this patient population. Keywords: human leukocyte antigen, antibodies, desensitization, high-dose intravenous immunoglobulin, rituximab

  19. High Speed Fibre Optic Backbone LAN

    Science.gov (United States)

    Tanimoto, Masaaki; Hara, Shingo; Kajita, Yuji; Kashu, Fumitoshi; Ikeuchi, Masaru; Hagihara, Satoshi; Tsuzuki, Shinji

    1987-09-01

    Our firm has developed the SUMINET-4100 series, a fibre optic local area network (LAN), to serve the communications system trunk line needs for facilities, such as steel refineries, automobile plants and university campuses, that require large transmission capacity, and for the backbone networks used in intelligent building systems. The SUMINET-4100 series is already in service in various fields of application. Of the networks available in this series, the SUMINET-4150 has a trunk line speed of 128 Mbps and the multiplexer used for time division multiplexing (TDM) was enabled by designing an ECL-TTL gate array (3000 gates) based custom LSI. The synchronous, full-duplex V.24 and V.3.5 interfaces (SUMINET-2100) are provided for use with general purpose lines. And the IBM token ring network, the SUMINET-3200, designed for heterogeneous PCs and the Ethernet can all be connected to sub loops. Further, the IBM 3270 TCA and 5080 CADAM can be connected in the local mode. Interfaces are also provided for the NTT high-speed digital service, the digital PBX systems, and the Video CODEC system. The built-in loop monitor (LM) and network supervisory processor (NSP) provide management of loop utilization and send loop status signals to the host CPU's network configuration and control facility (NCCF). These built-in functions allow both the computer system and LAN to be managed from a single source at the host. This paper outlines features of the SUMINET-4150 and provides an example of its installation.

  20. Application of portable optical laboratory in high schools and colleges

    Science.gov (United States)

    Altshuler, Gregory B.; Belashenkov, Nickolai R.; Ermolaev, Vladimir S.; Inochkin, Mickle V.; Karasev, Vyatcheslav B.

    1995-10-01

    The present paper describes the experience of application of portable optical laboratory in optical practicum developed directly for training and demonstrations of basic optical laws and phenomena in high-schools, colleges and nontechnical universities all over Russia. The laboratory includes the portable optical platform with built-in laser and lamp sources, kit of optical components and software. These accessories provide the attractive and smart teaching in general optics during lectures, lessons and practice at schools and colleges. The portable optical laboratory provides 28 basic lab works and demonstrations in reflection, refraction, absorption and dispersion of light, interference, diffraction, polarization of light, image formation and waveguide propagation of light in optical fibers. Due to their interdependence one can teach and learn a whole course of general optics. The individual work of students and school children with optical kit stimulates and develops their creative abilities and experimental skills, as well increases the effectiveness of education. The kit is provided with optional elements for a number of extra experiments with holography, polarizing light propagation, simple optical devices etc. These extensions allow to modify the education process according to teacher's point of view. The conception of optical class-room based on portable optical laboratories is discussed. The effectiveness of individual and small-group training is analyzed.

  1. Mutagen sensitivity has high heritability: evidence from a twin study.

    Science.gov (United States)

    Wu, Xifeng; Spitz, Margaret R; Amos, Christopher I; Lin, Jie; Shao, Lina; Gu, Jian; de Andrade, Mariza; Benowitz, Neal L; Shields, Peter G; Swan, Gary E

    2006-06-15

    Despite numerous studies showing that mutagen sensitivity is a cancer predisposition factor, the heritability of mutagen sensitivity has not been clearly established. In this report, we used a classic twin study design to examine the role of genetic and environmental factors on the mutagen sensitivity phenotype. Mutagen sensitivity was measured in peripheral blood lymphocytes from 460 individuals [148 pairs of monozygotic (MZ) twins, 57 pairs of dizygotic (DZ) twins, and 50 siblings]. The intraclass correlation coefficients were all significantly higher in MZ twins than in dizygotes (DZ pairs and MZ-sibling pairs combined) for sensitivity to four different mutagen challenges. Applying biometric genetic modeling, we calculated a genetic heritability of 40.7%, 48.0%, 62.5%, and 58.8% for bleomycin, benzo[a]pyrene diol epoxide, gamma-radiation, and 4-nitroquinoline-1-oxide sensitivity, respectively. This study provides the strongest and most direct evidence that mutagen sensitivity is highly heritable, thereby validating the use of mutagen sensitivity as a cancer susceptibility factor.

  2. Improving Mars-GRAM: Increasing the Accuracy of Sensitivity Studies at Large Optical Depths

    Science.gov (United States)

    Justh, Hilary L.; Justus, C. G.; Badger, Andrew M.

    2010-01-01

    Extensively utilized for numerous mission applications, the Mars Global Reference Atmospheric Model (Mars-GRAM) is an engineering-level atmospheric model. In a Monte-Carlo mode, Mars-GRAM's perturbation modeling capability is used to perform high fidelity engineering end-to-end simulations for entry, descent, and landing (EDL). Mars-GRAM has been found to be inexact when used during the Mars Science Laboratory (MSL) site selection process for sensitivity studies for MapYear=0 and large optical depth values such as tau=3. Mars-GRAM is based on the NASA Ames Mars General Circulation Model (MGCM) from the surface to 80 km altitude. Mars-GRAM with the MapYear parameter set to 0 utilizes results from a MGCM run with a fixed value of tau=3 at all locations for the entire year. Imprecise atmospheric density and pressure at all altitudes is a consequence of this use of MGCM with tau=3. Density factor values have been determined for tau=0.3, 1 and 3 as a preliminary fix to this pressure-density problem. These factors adjust the input values of MGCM MapYear 0 pressure and density to achieve a better match of Mars-GRAM MapYear 0 with Thermal Emission Spectrometer (TES) observations for MapYears 1 and 2 at comparable dust loading. These density factors are fixed values for all latitudes and Ls and are included in Mars-GRAM Release 1.3. Work currently being done, to derive better multipliers by including variations with latitude and/or Ls by comparison of MapYear 0 output directly against TES limb data, will be highlighted in the presentation. The TES limb data utilized in this process has been validated by a comparison study between Mars atmospheric density estimates from Mars-GRAM and measurements by Mars Global Surveyor (MGS). This comparison study was undertaken for locations on Mars of varying latitudes, Ls, and LTST. The more precise density factors will be included in Mars-GRAM 2005 Release 1.4 and thus improve the results of future sensitivity studies done for large

  3. The influence of photoreceptor size and distribution on optical sensitivity in the eyes of lanternfishes (Myctophidae.

    Directory of Open Access Journals (Sweden)

    Fanny de Busserolles

    Full Text Available The mesopelagic zone of the deep-sea (200-1000 m is characterised by exponentially diminishing levels of downwelling sunlight and by the predominance of bioluminescence emissions. The ability of mesopelagic organisms to detect and behaviourally react to downwelling sunlight and/or bioluminescence will depend on the visual task and ultimately on the eyes and their capacity for detecting low levels of illumination and intermittent point sources of bioluminescent light. In this study, we investigate the diversity of the visual system of the lanternfish (Myctophidae. We focus specifically on the photoreceptor cells by examining their size, arrangement, topographic distribution and contribution to optical sensitivity in 53 different species from 18 genera. We also examine the influence(s of both phylogeny and ecology on these photoreceptor variables using phylogenetic comparative analyses in order to understand the constraints placed on the visual systems of this large group of mesopelagic fishes at the first stage of retinal processing. We report great diversity in the visual system of the Myctophidae at the level of the photoreceptors. Photoreceptor distribution reveals clear interspecific differences in visual specialisations (areas of high rod photoreceptor density, indicating potential interspecific differences in interactions with prey, predators and/or mates. A great diversity in photoreceptor design (length and diameter and density is also present. Overall, the myctophid eye is very sensitive compared to other teleosts and each species seems to be specialised for the detection of a specific signal (downwelling light or bioluminescence, potentially reflecting different visual demands for survival. Phylogenetic comparative analyses highlight several relationships between photoreceptor characteristics and the ecological variables tested (depth distribution and luminous tissue patterns. Depth distribution at night was a significant factor in most

  4. The influence of photoreceptor size and distribution on optical sensitivity in the eyes of lanternfishes (Myctophidae)

    KAUST Repository

    de Busserolles, Fanny

    2014-06-13

    The mesopelagic zone of the deep-sea (200-1000 m) is characterised by exponentially diminishing levels of downwelling sunlight and by the predominance of bioluminescence emissions. The ability of mesopelagic organisms to detect and behaviourally react to downwelling sunlight and/or bioluminescence will depend on the visual task and ultimately on the eyes and their capacity for detecting low levels of illumination and intermittent point sources of bioluminescent light. In this study, we investigate the diversity of the visual system of the lanternfish (Myctophidae). We focus specifically on the photoreceptor cells by examining their size, arrangement, topographic distribution and contribution to optical sensitivity in 53 different species from 18 genera. We also examine the influence(s) of both phylogeny and ecology on these photoreceptor variables using phylogenetic comparative analyses in order to understand the constraints placed on the visual systems of this large group of mesopelagic fishes at the first stage of retinal processing. We report great diversity in the visual system of the Myctophidae at the level of the photoreceptors. Photoreceptor distribution reveals clear interspecific differences in visual specialisations (areas of high rod photoreceptor density), indicating potential interspecific differences in interactions with prey, predators and/or mates. A great diversity in photoreceptor design (length and diameter) and density is also present. Overall, the myctophid eye is very sensitive compared to other teleosts and each species seems to be specialised for the detection of a specific signal (downwelling light or bioluminescence), potentially reflecting different visual demands for survival. Phylogenetic comparative analyses highlight several relationships between photoreceptor characteristics and the ecological variables tested (depth distribution and luminous tissue patterns). Depth distribution at night was a significant factor in most of the

  5. Electronic and optical properties of dye-sensitized TiO₂ interfaces.

    Science.gov (United States)

    Pastore, Mariachiara; Selloni, Annabella; Fantacci, Simona; De Angelis, Filippo

    2014-01-01

    Dye-sensitized solar cells (DSCs) represent a promising approach to the direct conversion of sunlight to electrical energy at low cost and high efficiency. DSCs are based on a film of anatase TiO₂ nanoparticles covered by adsorbed molecular dyes and immersed in a liquid redox electrolyte. Upon photoexcitation of the chemisorbed dye, electrons are injected into the TiO₂ conduction band and can travel across the nanostructured film to reach the counter-electrode, while the oxidized dye is regenerated by the redox electrolyte. In this review we present a summary of recent computational studies of the electronic and optical properties of dye-sensitized TiO2 interfaces, with the aim of providing the basic understanding of the operation principles of DSCs and establishing the conceptual basis for their design and optimization.We start with a discussion of isolated dyes in solution, focusing on the dye's atomic structure, ground and excited state oxidation potentials, and optical absorption spectra. We examine both Ru(II)-polypyridyl complexes and organic "push-pull" dyes with a D-π-A structure, where the donor group (D) is an electron-rich unit, linked through a conjugated linker (π) to the electron-acceptor group (A). We show that a properly calibrated computational approach based on Density Functional Theory (DFT) combined with Time Dependent DFT (TD-DFT) can provide a good description of both the absorption spectra and ground and excited state oxidation potential values of the Ru(II) complexes. On the other hand, organic push-pull dyes are not well described by the standard DFT/TD-DFT approach. For these dyes, an excellent description of the electronic structure in gas phase can be obtained by the many body perturbation theory GW method, which has, however, a much higher computational cost.We next consider interacting dye/semiconductor systems. Key properties are the dye adsorption structure onto the semiconductor, the nature and localization of the dye

  6. Sensitive Detection of Small Particles in Fluids Using Optical Fiber Tip with Dielectrophoresis

    Directory of Open Access Journals (Sweden)

    Yi-Hsin Tai

    2016-02-01

    Full Text Available This work presents using a tapered fiber tip coated with thin metallic film to detect small particles in water with high sensitivity. When an AC voltage applied to the Ti/Al coated fiber tip and indium tin oxide (ITO substrate, a gradient electric field at the fiber tip induced attractive/repulsive force to suspended small particles due to the frequency-dependent dielectrophoresis (DEP effect. Such DEP force greatly enhanced the concentration of the small particles near the tip. The increase of the local concentration also increased the scattering of surface plasmon wave near the fiber tip. Combined both DEP effect and scattering optical near-field, we show the detection limit of the concentration for 1.36 μm polystyrene beads can be down to 1 particle/mL. The detection limit of the Escherichia coli (E. coli bacteria was 20 CFU/mL. The fiber tip sensor takes advantages of ultrasmall volume, label-free and simple detection system.

  7. Imaging natural and artificial demineralization on dentin surfaces with polarization sensitive optical coherence tomography.

    Science.gov (United States)

    Manesh, Saman K; Darling, Cynthia L; Fried, Daniel

    2008-01-01

    The purpose of this study was to assess the potential of polarization sensitive optical coherence tomography (PS-OCT) to measure non-destructively the severity of natural and artificial caries lesions in dentin and determine the efficacy of intervention with anti-caries agents. Although several studies have demonstrated the utility of PS-OCT to image caries lesions in enamel and to quantify the lesion severity, only a few studies have focused on lesions in dentin. In this study images of natural root caries lesions on extracted human teeth were acquired with PS-OCT. In addition artificial lesions were produced in dentin after 12 days of exposure to a demineralization solution at a pH of 5.0. Before exposure, three incisions were made on the sample surfaces using Er:YAG laser irradiation and selected areas were treated with topical fluoride. PS-OCT images were acquired using a high power (45-mw) 1310-nm superluminescent diode with a bandwidth of 35-nm. PS-OCT was able to measure demineralization in dentin to a depth of ~ 1 mm. Polarized light microscopy and microradiography were used to measure lesion severity on histological thin sections for comparison. PS-OCT successfully measured the inhibition of demineralization by topical fluoride. Er:YAG laser irradiation did not significantly increase or decrease the rate of dentin demineralization.

  8. Imaging caries lesions and lesion progression with polarization-sensitive optical coherence tomography

    Science.gov (United States)

    Fried, Daniel; Xie, John; Shafi, Sahar; Featherstone, John D. B.; Breunig, Thomas; Le, Charles Q.

    2002-06-01

    New diagnostic tools are needed for the characterization of dental caries in the early stages of development. If carious lesions are detected early enough, they can be arrested without the need for surgical intervention. The objective of this study was to demonstrate that polarization sensitive optical coherence tomography (PS-OCT) can be used for the imaging of early caries lesions and for the monitoring of lesion progression over time. High-resolution polarization resolved images were acquired of natural caries lesions and simulated caries lesions of varying severity created over time periods of 1 to 14 days. Linearly polarized light was incident on the tooth samples and the reflected intensity in both orthogonal polarizations was measured. PS-OCT was invaluable for removing the confounding influence of surface reflections and native birefringence and for resolving the surface structure of caries lesions. This study demonstrated that PS-OCT is well suited for the resolution of interproximal and occlusal caries, early root caries, and secondary caries around composite fillings. Longitudinal measurements of lesion progression established a strong correlation (p<0.001) between the reflected light from the lesion area and the square root of time indicating that PS-OCT is well suited for monitoring changes in enamel mineralization over time.

  9. An optical fiber spool for laser stabilization with reduced acceleration sensitivity to 10-12/g

    Institute of Scientific and Technical Information of China (English)

    胡永奇; 董靖; 黄军超; 李唐; 刘亮

    2015-01-01

    Environmental vibration causes mechanical deformation in optical fibers, which induces excess frequency noise in fiber-stabilized lasers. In order to solve such a problem, we propose an ultralow acceleration sensitivity fiber spool with symmetrically mounted structure. By numerical analysis with the finite element method, we obtain the optimal geometry parameters of the spool with which the horizontal and vertical acceleration sensitivity can be reduced to 3.25 × 10−12/g and 5.38 × 10−12/g respectively. Moreover, the structure features the insensitivity to the variation of geometry parameters, which will minimize the infl uence from numerical simulation error and manufacture tolerance.

  10. Non-invasive assessment of corneal crosslinking changes using polarization sensitive optical coherence tomography

    Science.gov (United States)

    Alonso-Caneiro, D.; Yamanari, M.; Fukuda, S.; Hoshi, S.; Nagase, S.; Oshika, T.; Yasuno, Y.; Collins, M.

    2013-03-01

    Collagen crosslinking (CXL) has shown promising results in the prevention of the progression of keratoconus and corneal ectasia. However, techniques for in vivo and in situ assessment of the treatment are limited. In this study, ex vivo porcine eyes were treated with a chemical CXL agent (glutaraldehyde), during which polarization sensitive optical coherence tomography (PS-OCT) recordings were acquired simultaneously to assess the sensitivity of the technique to assess changes in the cornea. The results obtained in this study suggest that PSOCT may be a suitable technique to measure CXL changes in situ and to assess the local changes in the treated region of the cornea.

  11. Strategies to Improve the Accuracy of Mars-GRAM Sensitivity Studies at Large Optical Depths

    Science.gov (United States)

    Justh, Hilary L.; Justus, Carl G.; Badger, Andrew M.

    2010-01-01

    The poster provides an overview of techniques to improve the Mars Global Reference Atmospheric Model (Mars-GRAM) sensitivity. It has been discovered during the Mars Science Laboratory (MSL) site selection process that the Mars Global Reference Atmospheric Model (Mars-GRAM) when used for sensitivity studies for TES MapYear = 0 and large optical depth values such as tau = 3 is less than realistic. A preliminary fix has been made to Mars-GRAM by adding a density factor value that was determined for tau = 0.3, 1 and 3.

  12. A fibre-optic diode laser spectrometer for sensitive simultaneous measurement of CO{sub 2} and CO gas concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Engelbrecht, R.; Euring, J.; Kuntz, F.; Schmidt, L.P. [Erlangen-Nuernberg Univ., Erlangen (DE). Lehrstuhl fuer Elektrotechnik (Hochfrequenztechnik)

    2001-07-01

    Many technically relevant molecules like CO{sub 2}, CO or H{sub 2}O have characteristic absorption lines for infrared light at specific wavelengths. The application of tunable diode laser absorption spectroscopy (TDLAS) has been demonstrated for atmospheric pollution detection, for combustion control in industrial processes, and in the exhaust of automotive engines. Due to the need for expensive custom-made diode lasers at non-standard wavelengths and delicate to align optics, such systems were often used only in laboratory environments. Recently, the advance of wideband fibre-optic communication systems has opened new perspectives. Diode lasers in the so-called L-band from 1565 nm to 1620 nm are now available. These lasers are mature products with high stability and reliability as required for high-speed communication networks and for industrial applications. At the Lehrstuhl fuer Hochfrequenztechnik we have developed a sensitive spectrometer using such commercially available diode lasers for the simultaneous measurement of CO{sub 2} and CO concentrations. By using fibre-optic components the spectrometer is much more flexible in application and less critical in alignment than systems with free-space optics. (orig.)

  13. Achieving sensitive, high-resolution laser spectroscopy at CRIS

    Energy Technology Data Exchange (ETDEWEB)

    Groote, R. P. de [Instituut voor Kern- en Stralingsfysica, KU Leuven (Belgium); Lynch, K. M., E-mail: kara.marie.lynch@cern.ch [EP Department, CERN, ISOLDE (Switzerland); Wilkins, S. G. [The University of Manchester, School of Physics and Astronomy (United Kingdom); Collaboration: the CRIS collaboration

    2017-11-15

    The Collinear Resonance Ionization Spectroscopy (CRIS) experiment, located at the ISOLDE facility, has recently performed high-resolution laser spectroscopy, with linewidths down to 20 MHz. In this article, we present the modifications to the beam line and the newly-installed laser systems that have made sensitive, high-resolution measurements possible. Highlights of recent experimental campaigns are presented.

  14. Sensitivity of Bragg gratings in birefringent optical fiber to transverse compression between conforming materials.

    Science.gov (United States)

    Dennison, Christopher R; Wild, Peter M

    2010-04-20

    A theoretical and experimental investigation of the transverse load sensitivity of Bragg gratings in birefringent fibers to conforming contact is presented. A plane elasticity model is used to predict the contact dimensions between a conforming material and optical fiber and the principal stresses, indicating birefringence, created as a result of this contact. The transverse load sensitivity of commercially available birefringent fiber is experimentally measured for two cases of conforming contact. Theoretical and experimental results show that birefringent optical fiber can be used to make modulus-independent measurements of contact load. Therefore, Bragg gratings could be applied to conforming contact load measurements while avoiding some of the complications associated with existing contact sensors: specifically, the necessity to precalibrate by using materials with mechanical properties identical to those found in situ.

  15. Influence of Temperature Variation on Optical Receiver Sensitivity and its Compensation

    Directory of Open Access Journals (Sweden)

    A. Prokes

    2007-09-01

    Full Text Available In the paper, the influence of temperature variation on the sensitivity of an avalanche-photodiode-based optical receiver applied in the free space optical communication link is discussed. Communication systems of this type are exposed to a wide range of operating temperatures, which markedly affect many photodiode and preamplifier parameters. The paper presents a receiver sensitivity calculation, taking into consideration the temperature dependence of avalanche photodiode gain, excess noise factor, dark current and thermal noise of preamplifier resistances, and describes the compensation of temperature effects on photodiode gain based on a corresponding change in the reverse voltage applied to the diode. The calculations are demonstrated on the connection of a small-area silicon APD operating in the wavelength range from 820 to 1150 nm with a transimpedance preamplifier using a bipolar junction transistor.

  16. High-sensitivity 3 to 5 micron PPLN LADAR wavelength converter system

    Science.gov (United States)

    Kingsley, S. A.; Sriram, S.; Powers, P. E.

    2005-05-01

    Remote sensing systems, such as LIDAR, have benefited greatly from nonlinear sources capable of generating tunable mid-infrared wavelengths (3-5 microns). Much work has focused on improving the energy output of these sources so as to improve the system's range. We present a different approach to improving the range by focusing on improving the receiver of a LADAR system employing nonlinear optical techniques. In this paper, we will present results of a receiver system based on frequency converting mid-infrared wavelengths to the 1.5 μm region using Periodically-Poled Lithium Niobate (PPLN). By doing so, optical amplifiers and avalanche photodetectors (APDs) developed for the fiber optics communications industry can be used, thus providing very high detection sensitivity and high speed without the need for cryogenically cooled optical detectors. We will present results of laboratory experiments with 3 μm, 2.5 ns FWHM LADAR pulses that have been converted to 1.5 μm. Detection sensitivities as low as 1.5 x 10^-13 Joules have been demonstrated. The performance of the Peltier-cooled 1.5 μm InGaAs APD quasi photon-counting receiver will be described.

  17. High-speed optical correlation-domain reflectometry without using acousto-optic modulator

    CERN Document Server

    Shizuka, Makoto; Hayashi, Neisei; Mizuno, Yosuke; Nakamura, Kentaro

    2015-01-01

    To achieve a distributed reflectivity measurement along an optical fiber, we develop a simplified cost-effective configuration of optical correlation- (or coherence-) domain reflectometry based on a synthesized optical coherence function by sinusoidal modulation. By excluding conventional optical heterodyne detection (practically, without using an acousto-optic modulator) and by exploiting the foot of the Fresnel reflection spectrum, the electrical bandwidth required for signal processing is lowered down to several megahertz. We evaluate the basic system performance and demonstrate its high-speed operation (10 ms for one scan) by tracking a moving reflection point in real time.

  18. Miniaturized High Performance Optical Gyroscope Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose a new approach for to the design and fabrication of miniaturized Interferometric Fiber Optical Gyroscope (FOG) that enables the production of smaller IRU...

  19. Fiber-Based Polarization Diversity Detection for Polarization-Sensitive Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Hamid Pahlevaninezhad

    2014-09-01

    Full Text Available We present a new fiber-based polarization diversity detection (PDD scheme for polarization sensitive optical coherence tomography (PSOCT. This implementation uses a new custom miniaturized polarization-maintaining fiber coupler with single mode (SM fiber inputs and polarization maintaining (PM fiber outputs. The SM fiber inputs obviate matching the optical lengths of the two orthogonal OCT polarization channels prior to interference while the PM fiber outputs ensure defined orthogonal axes after interference. Advantages of this detection scheme over those with bulk optics PDD include lower cost, easier miniaturization, and more relaxed alignment and handling issues. We incorporate this PDD scheme into a galvanometer-scanned OCT system to demonstrate system calibration and PSOCT imaging of an achromatic quarter-wave plate, fingernail in vivo, and chicken breast, salmon, cow leg, and basa fish muscle samples ex vivo.

  20. A portable optical DSPI strain sensor with radial sensitivity using an axis-symmetrical DOE

    Science.gov (United States)

    Viotti, Matias R.; Kapp, Walter A.; Albertazzi Gonçalves, Armando, Jr.

    2010-09-01

    This paper presents the optical setup of a radial in-plane digital speckle pattern interferometer (DSPI) which uses an axissymmetrical diffractive optical element to obtain double illumination. The application of the DOE gives true in-plane sensitivity that is independent on the wavelength of the laser used as illumination source. Furthermore, it only depends on the grating period of the DOE. A new optical layout was introduced in order to obtain a circular measurement area of about 5 mm in diameter. A brief description of the DOE and the portable strain sensor are presented. A detailed explanation of the clamping system is presented showing its ability to deal with rigid body displacements. Finally, some experimental results are shown enlightening that it is able to measure mechanical stress fields from only one difference phase map.

  1. Optical Fiber/Nanowire Hybrid Structures for Efficient Three-Dimensional Dye-Sensitized Solar Cells

    KAUST Repository

    Weintraub, Benjamin

    2009-11-09

    Wired up: The energy conversion efficiency of three-dimensional dye-sensitized solar cells (DSSCs) in a hybrid structure that integrates optical fibers and nanowire arrays is greater than that of a two-dimensional device. Internal axial illumination enhances the energy conversion efficiency of a rectangular fiber-based hybrid structure (see picture) by a factor of up to six compared to light illumination normal to the fiber axis from outside the device.

  2. Polarization-Sensitive Interneurons in the Optic Lobe of the Desert Ant Cataglyphis bicolor

    Science.gov (United States)

    Labhart, Thomas

    Desert ants, Cataglyphis bicolor (Hymenoptera), navigate by using compass information provided by skylight polarization. In this study, electrophysiological recordings were made from polarization-sensitive interneurons (POL-neurons) in the optic lobe of Cataglyphis. The POL-neurons exhibit a characteristic polarization opponency. They receive monochromatic input from the UV receptors of the specialized dorsal rim area of the compound eye. Both polarization opponency and monochromacy are features also found in the POL-neurons of crickets (Orthoptera).

  3. Sensitized phosphorescence studies of p-xylene+biacetyl system, an optical antenna.

    Science.gov (United States)

    Bayrakçeken, Fuat

    2007-04-01

    p-Xylene sensitized biacetyl fluorescence and phosphorescence has been investigated and photosensitized phosphorescence lifetimes of biacetyl in the vapor phase has been determined. Attempts to detect the triplet of biacetyl by its absorption spectrum were unsuccessful, due to primarily, it is believed, to the low extinction coefficients of the triplet, and the low triplet concentrations produced by the optical pumping device at room temperature.

  4. Near-infrared absorption fiber-optic sensors for ultra-sensitive CO2 detection

    Science.gov (United States)

    Chong, Xinyuan; Kim, Ki-Joong; Ohodnicki, Paul R.; Chang, Chih-Hung; Wang, Alan X.

    2015-05-01

    We present a fiber-optic sensor working at near-infrared (NIR) wavelength (~1.57μm) for CO2 detection. In order to increase the NIR absorption, we utilize functional sensor materials metalorganic framework (MOF) on the surface of the core of a multimode-fiber with the cladding layer etched away. The selected functional materials demonstrated excellent adsorption capacity of CO2 and significantly increased the detection sensitivity down to 500 ppm with only 8-centimeter absorption length.

  5. A multichannel smartphone optical biosensor for high-throughput point-of-care diagnostics.

    Science.gov (United States)

    Wang, Li-Ju; Chang, Yu-Chung; Sun, Rongrong; Li, Lei

    2017-01-15

    Current reported smartphone spectrometers are only used to monitor or measure one sample at a time. For the first time, we demonstrate a multichannel smartphone spectrometer (MSS) as an optical biosensor that can simultaneously optical sense multiple samples. In this work, we developed a novel method to achieve the multichannel optical spectral sensing with nanometer resolution on a smartphone. A 3D printed cradle held the smartphone integrated with optical components. This optical sensor performed accurate and reliable spectral measurements by optical intensity changes at specific wavelength or optical spectral shifts. A custom smartphone multi-view App was developed to control the optical sensing parameters and to align each sample to the corresponding channel. The captured images were converted to the transmission spectra in the visible wavelength range from 400nm to 700nm with the high resolution of 0.2521nm per pixel. We validated the performance of this MSS via measuring the concentrations of protein and immunoassaying a type of human cancer biomarker. Compared to the standard laboratory instrument, the results sufficiently showed that this MSS can achieve the comparative analysis detection limits, accuracy and sensitivity. We envision that this multichannel smartphone optical biosensor will be useful in high-throughput point-of-care diagnostics with its minimizing size, light weight, low cost and data transmission function. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Temperature Sensitivity of an Atomic Vapor Cell-Based Dispersion-Enhanced Optical Cavity

    Science.gov (United States)

    Myneni, K.; Smith, D. D.; Chang, H.; Luckay, H. A.

    2015-01-01

    Enhancement of the response of an optical cavity to a change in optical path length, through the use of an intracavity fast-light medium, has previously been demonstrated experimentally and described theoretically for an atomic vapor cell as the intracavity resonant absorber. This phenomenon may be used to enhance both the scale factor and sensitivity of an optical cavity mode to the change in path length, e.g. in gyroscopic applications. We study the temperature sensitivity of the on-resonant scale factor enhancement, S(sub o), due to the thermal sensitivity of the lower-level atom density in an atomic vapor cell, specifically for the case of the Rb-87 D(sub 2) transition. A semi-empirical model of the temperature-dependence of the absorption profile, characterized by two parameters, a(sub o)(T) and gamma(sub a)(T) allows the temperature-dependence of the cavity response, S(sub o)(T) and dS(sub o)/dT to be predicted over a range of temperature. We compare the predictions to experiment. Our model will be useful in determining the useful range for S(sub o), given the practical constraints on temperature stability for an atomic vapor cell.

  7. Research of High Sensitivity Uncooled Infrared Detector Array

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Pingchuan [Huazhong University of Science and Technology, Wuhan 430074 (China); Zhang, Bo, E-mail: redmoon123456@126.com, E-mail: lhzyzb@126.com [Luohe Vocational Technology College, Luohe 462002 (China)

    2011-02-01

    The infrared thermal imaging technology has been widely used in military and civilian fields and the field of the infrared detection and infrared thermal imaging technology has been of concern for a long time. On infrared thermal imaging, its core components for the infrared focal plane arrays, how to develop a high sensitivity of the multi-focal plane infrared detector is a key issue. Although the Common focal plane array of quantum has high sensitivity, but it requires low temperature cooling work environment and led to complexity and high cost, difficult to compact. Conventional uncooled infrared focal plane array is contrast to the quantum focal plane arrays. Therefore, this article preceded by the uncooled infrared detector array to improve the wide temperature sensitivity in examining the feasibility PMN composite film, materials composition, structure design and preparation process technology.

  8. Amorphous silicon rich silicon nitride optical waveguides for high density integrated optics

    DEFF Research Database (Denmark)

    Philipp, Hugh T.; Andersen, Karin Nordström; Svendsen, Winnie Edith

    2004-01-01

    Amorphous silicon rich silicon nitride optical waveguides clad in silica are presented as a high-index contrast platform for high density integrated optics. Performance of different cross-sectional geometries have been measured and are presented with regards to bending loss and insertion loss...

  9. Amorphous silicon rich silicon nitride optical waveguides for high density integrated optics

    DEFF Research Database (Denmark)

    Philipp, Hugh T.; Andersen, Karin Nordström; Svendsen, Winnie Edith

    2004-01-01

    Amorphous silicon rich silicon nitride optical waveguides clad in silica are presented as a high-index contrast platform for high density integrated optics. Performance of different cross-sectional geometries have been measured and are presented with regards to bending loss and insertion loss....... A sample double ring add-drop filter is presented....

  10. Fast optical signal processing in high bit rate OTDM systems

    DEFF Research Database (Denmark)

    Poulsen, Henrik Nørskov; Jepsen, Kim Stokholm; Clausen, Anders;

    1998-01-01

    As all-optical signal processing is maturing, optical time division multiplexing (OTDM) has also gained interest for simple networking in high capacity backbone networks. As an example of a network scenario we show an OTDM bus interconnecting another OTDM bus, a single high capacity user...

  11. Optical performance of an ultra-sensitive horn-coupled transition-edge-sensor bolometer with hemispherical backshort in the far infrared

    CERN Document Server

    Audley, Michael D; Gao, Jian-Rong; Khosropanah, Pourya; Hijmering, Richard; Ridder, Marcel; Mauskopf, Philip D; Morozov, Dmitry; Trappe, Neil A; Doherty, Stephen

    2016-01-01

    The next generation of far infrared space observatories will require extremely sensitive detectors that can be realized only by combining extremely low intrinsic noise with high optical efficiency. We have measured the broad-band optical response of ultra-sensitive TES bolometers (NEP$\\approx2\\rm\\ aW/\\sqrt Hz$) in the 30--60-$\\mu\\rm m$ band where radiation is coupled to the detectors with a few-moded conical feedhorn and a hemispherical backshort. We show that these detectors have an optical efficiency of 60% (the ratio of the power detected by the TES bolometer to the total power propagating through the feedhorn). We find that the measured optical efficiency can be understood in terms of the modes propagating through the feedhorn with the aid of a spatial mode-filtering technique.

  12. Optically sensitive devices based on Pt nano particles fabricated by atomic layer deposition and embedded in a dielectric stack

    Energy Technology Data Exchange (ETDEWEB)

    Mikhelashvili, V.; Padmanabhan, R.; Eisenstein, G. [Electrical Engineering Department, Technion, Haifa 3200 (Israel); Russell Berrie Nanotechnology Institute, Technion, Haifa 3200 (Israel); Meyler, B.; Yofis, S.; Weindling, S.; Salzman, J. [Electrical Engineering Department, Technion, Haifa 3200 (Israel); Atiya, G.; Cohen-Hyams, Z.; Kaplan, W. D. [Department of Material Science and Engineering, Technion, Haifa 3200 (Israel); Russell Berrie Nanotechnology Institute, Technion, Haifa 3200 (Israel); Ankonina, G. [Russell Berrie Nanotechnology Institute, Technion, Haifa 3200 (Israel); Photovoltaic Laboratory, Technion, Haifa 3200 (Israel)

    2015-10-07

    We report a series of metal insulator semiconductor devices with embedded Pt nano particles (NPs) fabricated using a low temperature atomic layer deposition process. Optically sensitive nonvolatile memory cells as well as optical sensors: (i) varactors, whose capacitance-voltage characteristics, nonlinearity, and peak capacitance are strongly dependent on illumination intensity; (ii) highly linear photo detectors whose responsivity is enhanced due to the Pt NPs. Both single devices and back to back pairs of diodes were used. The different configurations enable a variety of functionalities with many potential applications in biomedical sensing, environmental surveying, simple imagers for consumer electronics and military uses. The simplicity and planar configuration of the proposed devices makes them suitable for standard CMOS fabrication technology.

  13. Ultra-sensitive near-infrared fiber-optic gas sensors enhanced by metal-organic frameworks

    Science.gov (United States)

    Chong, Xinyuan; Kim, Ki-Joong; Li, Erwen; Zhang, Yujing; Ohodnicki, Paul R.; Chang, Chih-Hung; Wang, Alan X.

    2016-03-01

    We demonstrate ultra-sensitive near-infrared (NIR) fiber-optic gas sensors enhanced by metalorganic framework (MOF) Cu-BTC (BTC=benzene-1,3,5- tricarboxylate), which is coated on a single-mode optical fiber. For the first time, we obtained high-resolution NIR spectroscopy of CO2 adsorbed in MOF without seeing any rotational side band. Real-time measurement showed different response time depending on the concentration of CO2, which is attributed to the complex adsorption and desorption mechanism of CO2 in Cu-BTC. The lowest detection limit of CO2 we achieved is 20 ppm with only 5-cm long Cu-BTC film.

  14. Optically sensitive devices based on Pt nano particles fabricated by atomic layer deposition and embedded in a dielectric stack

    Science.gov (United States)

    Mikhelashvili, V.; Padmanabhan, R.; Meyler, B.; Yofis, S.; Atiya, G.; Cohen-Hyams, Z.; Weindling, S.; Ankonina, G.; Salzman, J.; Kaplan, W. D.; Eisenstein, G.

    2015-10-01

    We report a series of metal insulator semiconductor devices with embedded Pt nano particles (NPs) fabricated using a low temperature atomic layer deposition process. Optically sensitive nonvolatile memory cells as well as optical sensors: (i) varactors, whose capacitance-voltage characteristics, nonlinearity, and peak capacitance are strongly dependent on illumination intensity; (ii) highly linear photo detectors whose responsivity is enhanced due to the Pt NPs. Both single devices and back to back pairs of diodes were used. The different configurations enable a variety of functionalities with many potential applications in biomedical sensing, environmental surveying, simple imagers for consumer electronics and military uses. The simplicity and planar configuration of the proposed devices makes them suitable for standard CMOS fabrication technology.

  15. Scalable photonic crystal chips for high sensitivity protein detection.

    Science.gov (United States)

    Liang, Feng; Clarke, Nigel; Patel, Parth; Loncar, Marko; Quan, Qimin

    2013-12-30

    Scalable microfabrication technology has enabled semiconductor and microelectronics industries, among other fields. Meanwhile, rapid and sensitive bio-molecule detection is increasingly important for drug discovery and biomedical diagnostics. In this work, we designed and demonstrated that photonic crystal sensor chips have high sensitivity for protein detection and can be mass-produced with scalable deep-UV lithography. We demonstrated label-free detection of carcinoembryonic antigen from pg/mL to μg/mL, with high quality factor photonic crystal nanobeam cavities.

  16. High-sensitivity, high-speed continuous imaging system

    Science.gov (United States)

    Watson, Scott A; Bender, III, Howard A

    2014-11-18

    A continuous imaging system for recording low levels of light typically extending over small distances with high-frame rates and with a large number of frames is described. Photodiode pixels disposed in an array having a chosen geometry, each pixel having a dedicated amplifier, analog-to-digital convertor, and memory, provide parallel operation of the system. When combined with a plurality of scintillators responsive to a selected source of radiation, in a scintillator array, the light from each scintillator being directed to a single corresponding photodiode in close proximity or lens-coupled thereto, embodiments of the present imaging system may provide images of x-ray, gamma ray, proton, and neutron sources with high efficiency.

  17. Sensitive detection of beryllium using a fiber optic liquid waveguide cell.

    Science.gov (United States)

    Deng, Gang; Wei, Lily; Collins, Greg E

    2003-05-28

    The metallochromic chelating agent, Chromazurol S, has been utilized in conjunction with a fiber optic liquid waveguide capillary cell to enable the sensitive detection of beryllium in solution (30 ng l(-1) detection limit) and following extraction from a contaminated plexiglas surface (0.5 ng cm(-2) detection limit). The addition of a cationic surfactant, cetylpyridinium chloride, to Chromazurol S at pH 10 in Tris-HCl buffer results in the formation of two bathochromic peaks in the visible spectrum following metal chelation by beryllium. The first absorbance band, at 515 nm, is intermediate in nature, permitting maximal sensitivity for low beryllium concentrations, but diminishing in intensity at concentrations above 100 mug l(-1). The second absorbance band, centered at 610 nm, dominates for beryllium concentrations of 100 mug l(-1) and above. Experimental conditions including pH, buffer type, additive surfactants, masking agents, and dye concentration were investigated in order to optimize detection sensitivity and selectivity. A fiber optic spectrometer is used with both a liquid waveguide capillary cell and 1 cm cuvette cell, to give a sensitive and broad dynamic range for beryllium detection that capitalizes on both beryllium metal chelate absorbance bands formed under these conditions.

  18. Optically transparent FTO-free cathode for dye-sensitized solar cells.

    Science.gov (United States)

    Kavan, Ladislav; Liska, Paul; Zakeeruddin, Shaik M; Grätzel, Michael

    2014-12-24

    The woven fabric containing electrochemically platinized tungsten wire is an affordable flexible cathode for liquid-junction dye-sensitized solar cells with the I3(-)/I(-) redox mediator and electrolyte solution consisting of ionic liquids and propionitrile. The fabric-based electrode outperforms the thermally platinized FTO in serial ohmic resistance and charge-transfer resistance for triiodide reduction, and it offers comparable or better optical transparency in the visible and particularly in the near-IR spectral region. The electrode exhibits good stability during electrochemical loading and storage at open circuit. The dye-sensitized solar cells with a C101-sensitized titania photoanode and either Pt-W/PEN or Pt-FTO cathodes show a comparable performance.

  19. Correlation between polarization sensitive optical coherence tomography and SHG microscopy in articular cartilage

    Science.gov (United States)

    Zhou, Xin; Ju, Myeong Jin; Huang, Lin; Tang, Shuo

    2017-02-01

    Polarization-sensitive optical coherence tomography (PS-OCT) and second harmonic generation (SHG) microscopy are two imaging modalities with different resolutions, field-of-views (FOV), and contrasts, while they both have the capability of imaging collagen fibers in biological tissues. PS-OCT can measure the tissue birefringence which is induced by highly organized fibers while SHG can image the collagen fiber organization with high resolution. Articular cartilage, with abundant structural collagen fibers, is a suitable sample to study the correlation between PS-OCT and SHG microscopy. Qualitative conjecture has been made that the phase retardation measured by PS-OCT is affected by the relationship between the collagen fiber orientation and the illumination direction. Anatomical studies show that the multilayered architecture of articular cartilage can be divided into four zones from its natural surface to the subchondral bone: the superficial zone, the middle zone, the deep zone, and the calcified zone. The different zones have different collagen fiber orientations, which can be studied by the different slopes in the cumulative phase retardation in PS-OCT. An algorithm is developed based on the quantitative analysis of PS-OCT phase retardation images to analyze the microstructural features in swine articular cartilage tissues. This algorithm utilizes the depth-dependent slope changing of phase retardation A-lines to segment structural layers. The results show good consistency with the knowledge of cartilage morphology and correlation with the SHG images measured at selected depth locations. The correlation between PS-OCT and SHG microscopy shows that PS-OCT has the potential to analyze both the macro and micro characteristics of biological tissues with abundant collagen fibers and other materials that may cause birefringence.

  20. Sensitivity of aerosol optical thickness and aerosol direct radiative effect to relative humidity

    Directory of Open Access Journals (Sweden)

    H. Bian

    2009-04-01

    Full Text Available We present a sensitivity study of the effects of spatial and temporal resolution of atmospheric relative humidity (RH on calculated aerosol optical thickness (AOT and the aerosol direct radiative effects (DRE in a global model. We carry out different modeling experiments using the same aerosol fields simulated in the Global Modeling Initiative (GMI model at a resolution of 2° latitude by 2.5° longitude, using time-averaged fields archived every three hours by the Goddard Earth Observation System Version 4 (GEOS-4, but we change the horizontal and temporal resolution of the relative humidity fields. We find that, on a global average, the AOT calculated using RH at a 1°×1.25° horizontal resolution is 11% higher than that using RH at a 2°×2.5° resolution, and the corresponding DRE at the top of the atmosphere is 8–9% and 15% more negative (i.e., more cooling for total aerosols and anthropogenic aerosol alone, respectively, in the finer spatial resolution case. The difference is largest over surface escarpment regions (e.g. >200% over the Andes Mountains where RH varies substantially with surface terrain. The largest zonal mean AOT difference occurs at 50–60° N (16–21%, where AOT is also relatively larger. A similar impact is also found when the time resolution of RH is increased. This increase of AOT and aerosol cooling with the increase of model resolution is due to the highly non-linear relationship between RH and the aerosol mass extinction efficiency (MEE at high RH (>80%. Our study is a specific example of the uncertainty in model results highlighted by multi-model comparisons such as AeroCom, and points out one of the many inter-model differences that can contribute to the overall spread among models.

  1. Nonlinear optical signal processing for high-speed, spectrally efficient fiber optic systems and networks

    Science.gov (United States)

    Zhang, Bo

    The past decade has witnessed astounding boom in telecommunication network traffic. With the emergence of multimedia over Internet, the high-capacity optical transport systems have started to shift focus from the core network towards the end users. This trend leads to diverse optical networks with transparency and reconfigurability requirement. As single channel data rate continues to increase and channel spacing continues to shrink for high capacity, high spectral efficiency, the workload on conventional electronic signal processing elements in the router nodes continues to build up. Performing signal processing functions in the optical domain can potentially alleviate the speed bottleneck if the unique optical properties are efficiently leveraged to assist electronic processing methodologies. Ultra-high bandwidth capability along with the promise for multi-channel and format-transparent operation make optical signal processing an attractive technology which is expected to have great impact on future optical networks. For optical signal processing applications in fiber-optic network and systems, a laudable goal would be to explore the unique nonlinear optical processes in novel photonic devices. This dissertation investigates novel optical signal processing techniques through simulations and experimental demonstrations, analyzes limitations of these nonlinear processing elements and proposes techniques to enhance the system performance or designs for functional photonic modules. Two key signal-processing building blocks for future optical networks, namely slow-light-based tunable optical delay lines and SOA-based high-speed wavelength converters, are presented in the first part of the dissertation. Phase preserving and spectrally efficient slow light are experimentally demonstrated using advanced modulation formats. Functional and novel photonic modules, such as multi-channel synchronizer and variable-bit-rate optical time division multiplexer are designed and

  2. Radiative Effect of Clouds on Tropospheric Chemistry: Sensitivity to Cloud Vertical Distributions and Optical Properties

    Science.gov (United States)

    Liu, H.; Crawford, J. H.; Pierce, R. B.; Considine, D. B.; Logan, J. A.; Duncan, B. N.; Norris, P.; Platnick, S. E.; Chen, G.; Yantosca, R. M.; Evans, M. J.

    2005-12-01

    Representation of clouds in global models poses a significant challenge since most cloud processes occur on sub-grid scales and must be parameterized. Uncertainties in cloud distributions and optical properties are therefore a limiting factor in model assessments of the radiative effect of clouds on global tropospheric chemistry. We present an analysis of the sensitivity of the radiative effect of clouds to cloud vertical distributions and optical properties with the use of the GEOS-CHEM global 3-D chemistry transport model coupled with the Fast-J radiative transfer algorithm. GEOS-CHEM was driven with a series of meteorological archives (GEOS1-STRAT, GEOS-3, and GEOS-4) generated by the Goddard Earth Observing System data assimilation system (GEOS DAS) at the NASA global Modeling and Assimilation Office (GMAO), which have significantly different cloud optical depths and vertical distributions. The column cloud optical depths in GEOS-3 generally agree with the satellite retrieval products from the Moderate Resolution Imaging Spectroradiometer (MODIS) and the International Satellite Cloud Climatology Project (ISCCP) within ±10%, while those in GEOS1-STRAT and GEOS-4 are too low by factors of about 5 and 2, respectively. With respect to vertical distribution, clouds in GEOS-4 are optically much thinner in the tropical upper troposphere compared to those in GEOS1-STRAT and GEOS-3. Assuming linear scaling of cloud optical depth with cloud fraction in a grid-box, our model calculations indicate that the changes in global mean hydroxyl radical (OH) due to the radiative effect of clouds in June are about -1% (GEOS1-STRAT), 1% (GEOS-3), and 14% (GEOS-4), respectively. The effects on global mean OH are similar for GEOS1-STRAT and GEOS-3 due to similar vertical distributions of clouds, even though the column cloud optical depths in the two archives differ by a factor of about 5. Clouds in GEOS-4 have a much larger impact on global mean OH because more solar radiation is

  3. An inexpensive high-temperature optical fiber thermometer

    Science.gov (United States)

    Moore, Travis J.; Jones, Matthew R.; Tree, Dale R.; Allred, David D.

    2017-01-01

    An optical fiber thermometer consists of an optical fiber whose tip is coated with a highly conductive, opaque material. When heated, this sensing tip becomes an isothermal cavity that emits like a blackbody. This emission is used to predict the sensing tip temperature. In this work, analytical and experimental research has been conducted to further advance the development of optical fiber thermometry. An inexpensive optical fiber thermometer is developed by applying a thin coating of a high-temperature cement onto the tip of a silica optical fiber. An FTIR spectrometer is used to detect the spectral radiance exiting the fiber. A rigorous mathematical model of the irradiation incident on the detection system is developed. The optical fiber thermometer is calibrated using a blackbody radiator and inverse methods are used to predict the sensing tip temperature when exposed to various heat sources.

  4. Sensitive Method for Enantioseparation of Rivastigmine with Highly Sulfated Cyclodextrin as Chiral Selector by Capillary Electrophoresis

    Institute of Scientific and Technical Information of China (English)

    WANG Zhao-Yan; XU Xing-Xiang; HU Zhi-De; KANG Jing-Wu

    2006-01-01

    A sensitive method for enantioseparation of a basic drug rivastigmine and determination of its optical impurity by capillary electrophoresis with highly sulfatedβ-cyclodextrin (HS-β-CD) as the chiral selector is described. In general, enantioseparation of basic chiral compounds is carried out in acidic condition (pH 2.5) to prevent analytes from adsorption on the capillary wall. However, in the case of rivastigmine, the detection sensitivity was too limited to determine the optical impurity of S-rivastigmine lower than 1% when buffer pH was 2.5. It was found that the detection sensitivity was improved 1.6 times just by raising the buffer pH value from 2.5 to 5.8. The poor column efficiency due to the adsorption of the analytes on the capillary wall was resolved by using dynamical coating of the capillary wall with the linear polyacrylamide solution. The experimental parameters such as the concentration of HS-β-CD, buffer pH and buffer ionic strength were optimized, respectively. The method was validated in terms of repeatability, linearity, limit of detection (LOD) and limit of quantitation (LOQ). Using the present method, the optical purity of nonracemic rivastigmine with the enantiomeric excess (ee) value of 99.14% was determined.

  5. Sub-picometer multi-wavelength detector based on highly sensitive nanomechanical resonator

    Science.gov (United States)

    Maeda, Etsuo; Kometani, Reo

    2017-07-01

    The wavelength division multiplexing (WDM) method for near infrared (NIR) optical fiber (1530-1565 nm) is the system that is wildly used for intercontinental communication. WDM achieves high-speed and large-capacity communication, but costs a lot because the high-resolution (˜10 pm) wavelength locker for wavelength stabilization only corresponds to a single wavelength. In this report, we propose a highly sensitive sub-picometer multi-wavelength detector that substitutes a typical single-wavelength detector for WDM. Our wavelength detector consists of a narrow band (FWHM 20 000) nanomechanical resonator. The photonic absorber confines and transforms the illuminated NIR light wave into thermal stress, and then, the thermal stress in the nanomechanical resonator will appear as the eigenfrequency shift of the nanomechanical resonator. Through experimental works with an NIR laser and optical Doppler vibration meter, the sensitivity of our wavelength detector was determined to be 0.196 pm in the 10-nm-range of the NIR region. Our sub-picometer multi-wavelength detector will achieve a fast, wide-band, and cost-effective optical communication system.

  6. Portable High Sensitivity and High Resolution Sensor to Determine Oxygen Purity Levels Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this Phase I STTR project is to develop a highly sensitive oxygen (O2) sensor, with high accuracy and precision, to determine purity levels of high...

  7. High-resolution retinal imaging using adaptive optics and Fourier-domain optical coherence tomography

    Science.gov (United States)

    Olivier, Scot S.; Werner, John S.; Zawadzki, Robert J.; Laut, Sophie P.; Jones, Steven M.

    2010-09-07

    This invention permits retinal images to be acquired at high speed and with unprecedented resolution in three dimensions (4.times.4.times.6 .mu.m). The instrument achieves high lateral resolution by using adaptive optics to correct optical aberrations of the human eye in real time. High axial resolution and high speed are made possible by the use of Fourier-domain optical coherence tomography. Using this system, we have demonstrated the ability to image microscopic blood vessels and the cone photoreceptor mosaic.

  8. High energy laser optics manufacturing: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Baird, E.D.

    1980-07-01

    This report presents concepts and methods, major conclusions, and major recommendations concerning the fabrication of high energy laser optics (HELO) that are to be machined by the Large Optics Diamond Turning Machine (LODTM) at the Lawrence Livermore National Laboratory (LLNL). Detailed discussions of concepts and methods proposed for metrological operations, polishing of reflective surfaces, mounting of optical components, construction of mirror substrates, and applications of coatings are included.

  9. The high education of optical engineering in East China

    Science.gov (United States)

    Liu, Xu; Liu, Xiangdong; Wang, Xiaoping; Bai, Jian; Liu, Yuling

    2014-07-01

    The history and the development of the high education in the field of optical engineering in the area of East China will be presented in the paper. The overall situation of research and human resource training in optics and photonics will also be reviewed, it shows that China needs lots of talents and experts in this field to support the world optical industry in East China.

  10. Aluminum nano-cantilevers for high sensitivity mass sensors

    DEFF Research Database (Denmark)

    Davis, Zachary James; Boisen, Anja

    2005-01-01

    We have fabricated Al nano-cantilevers using a very simple one mask contact UV lithography technique with lateral dimensions under 500 nm and vertical dimensions of approximately 100 nm. These devices are demonstrated as highly sensitive mass sensors by measuring their dynamic properties. Further...

  11. Highly Sensitive AMS Measurement of 53Mn at CIAE

    Institute of Scientific and Technical Information of China (English)

    DONG; Ke-jun; HU; Hao; LIU; Guang-shan; HE; Ming; LI; Zhen-yu; DOU; Liang; XIE; Lin-bo; LIU; Jian-cheng; WANG; Xiang-gao; SHEN; Hong-tao; LIN; De-yu; ZHENG; Guo-wen; WANG; Xiao-bo; LI; Heng; LI; Chao-li; WU; Shao-yong; YOU; Qu-bo; JIN; Chun-sheng; CHEN; Zhi-gang; YUAN; Jian; JIANG; Shan

    2013-01-01

    Methods for highly sensitive AMS measurement of 53Mn were explored by extracting different Mn-containing molecular ions in ion source and using different chemical forms of sample materials.Preliminary results indicate that a method for AMS measurement of 53Mn has been established and a-155355

  12. Sensitivity Study of Strapdown Inertial Sensors in High Performance Applications

    Science.gov (United States)

    1980-12-01

    system error varied with a change in heading 7K. ( xii 1 SENSITIVITY STUDY OF STRAPDOWN INERTIAL SENSORS IN HIGH PERFORMANCE APPLICATIONS I. Introduction...given in Tabla 10. 23 State Meaning o Basic Altitude Damped INS x(1) Error in East Longitude 5.7735 x 1O Ŗ arc min x(2) Error in North Latitude

  13. [Burner head with high sensitivity in atomic absorption spectroscopy].

    Science.gov (United States)

    Feng, X; Yang, Y

    1998-12-01

    This paper presents a burner head with gas-sample separate entrance and double access, which is used for atomic absorption spectroscopy. According to comparison and detection, the device can improve sensitivity by a factor of 1 to 5. In the meantime it has properties of high stability and resistance to interference.

  14. Microelectromechanical Resonant Accelerometer Designed with a High Sensitivity

    Science.gov (United States)

    Zhang, Jing; Su, Yan; Shi, Qin; Qiu, An-Ping

    2015-01-01

    This paper describes the design and experimental evaluation of a silicon micro-machined resonant accelerometer (SMRA). This type of accelerometer works on the principle that a proof mass under acceleration applies force to two double-ended tuning fork (DETF) resonators, and the frequency output of two DETFs exhibits a differential shift. The dies of an SMRA are fabricated using silicon-on-insulator (SOI) processing and wafer-level vacuum packaging. This research aims to design a high-sensitivity SMRA because a high sensitivity allows for the acceleration signal to be easily demodulated by frequency counting techniques and decreases the noise level. This study applies the energy-consumed concept and the Nelder-Mead algorithm in the SMRA to address the design issues and further increase its sensitivity. Using this novel method, the sensitivity of the SMRA has been increased by 66.1%, which attributes to both the re-designed DETF and the reduced energy loss on the micro-lever. The results of both the closed-form and finite-element analyses are described and are in agreement with one another. A resonant frequency of approximately 22 kHz, a frequency sensitivity of over 250 Hz per g, a one-hour bias stability of 55 μg, a bias repeatability (1σ) of 48 μg and the bias-instability of 4.8 μg have been achieved. PMID:26633425

  15. Microelectromechanical Resonant Accelerometer Designed with a High Sensitivity

    Directory of Open Access Journals (Sweden)

    Jing Zhang

    2015-12-01

    Full Text Available This paper describes the design and experimental evaluation of a silicon micro-machined resonant accelerometer (SMRA. This type of accelerometer works on the principle that a proof mass under acceleration applies force to two double-ended tuning fork (DETF resonators, and the frequency output of two DETFs exhibits a differential shift. The dies of an SMRA are fabricated using silicon-on-insulator (SOI processing and wafer-level vacuum packaging. This research aims to design a high-sensitivity SMRA because a high sensitivity allows for the acceleration signal to be easily demodulated by frequency counting techniques and decreases the noise level. This study applies the energy-consumed concept and the Nelder-Mead algorithm in the SMRA to address the design issues and further increase its sensitivity. Using this novel method, the sensitivity of the SMRA has been increased by 66.1%, which attributes to both the re-designed DETF and the reduced energy loss on the micro-lever. The results of both the closed-form and finite-element analyses are described and are in agreement with one another. A resonant frequency of approximately 22 kHz, a frequency sensitivity of over 250 Hz per g, a one-hour bias stability of 55 μg, a bias repeatability (1σ of 48 μg and the bias-instability of 4.8 μg have been achieved.

  16. 基于光纤M-Z干涉的高灵敏度液体折射率传感器的实验研究%Experimentally Study on High-sensitivity Fiber-optic Refractometers Based on Mach-Zehnder Interference

    Institute of Scientific and Technical Information of China (English)

    周赢武

    2012-01-01

    A high sensitivity fiber-optic refractive index sensor based on Mach-Zehnder interferometer is proposed and fabricated. The relationship between the resonance wavelength shifts to the refractive index is studied with NaCl and glycerin solution. The experimental results show that the resonance wavelength shifts to longer wavelength with the increase of the refractive index of the surrounding media, and the wavelength shift is nearly linear to the refractive index with a sensitivity is of 4 086 nm/refractive-index as the refractive index ranges from 1. 333 to 1. 356. The sensor is easy to fabricate, compact, and will be usefull in chemical and biotechnological industry.%提出并制备了一种基于Mach-Zehnder干涉效应的高灵敏度光纤液体折射率传感器.分别利用NaCl溶液和甘油溶液,研究了传感器的透射光谱和外界介质折射率的关系.实验结果表明,随着周围介质折射率的增大,传感器干涉谱的极小值点对应的波长向长波方向漂移,在1.333~1.356的折射率变化范围内,极小值点对应的波长的漂移量和折射率的变化具有较好的线性关系,对应的灵敏度约为4086 nm/refractive-index.该传感器制作简单、结构紧凑,在生物和化学测量中具有较好的应用前景.

  17. Highly sensitive curvature sensor based on a multicladding fiber sandwiched dual no-core fibers structure.

    Science.gov (United States)

    Qi, Yanhui; Ma, Lin; Kang, Zexin; Bai, Yunlong; Yin, Bin; Jian, Shuisheng

    2014-10-01

    In this paper, we present a simple, compact, and highly sensitive optical fiber curvature sensor. It consists of dual no-core fibers for coupling energy from the lead-in single-mode fiber (SMF), and recoupling the energy into the lead-out SMF. The sensing section is constituted by multicladding fiber with a length of 5 cm. In the experiment, the spectrum shows a blueshift, and the energy corresponding to the resonant wavelength shows a cosine series with a bending of the sensing segment. The curvature sensitivity around the wavelength of 1550 nm shows -39.02 nm/m(-1) within the curvature range from 0.3 to 2.14 m(-1). The temperature sensitivity is 78.2 pm/°C in the temperature range of 10 °C-60 °C. It implies the possibility of temperature measurement.

  18. High-sensitivity observations of solar flare decimeter radiation

    CERN Document Server

    Benz, Arnold O; Monstein, C; Benz, Arnold O.; Messmer, Peter; Monstein, Christian

    2000-01-01

    A new acousto-optic radio spectrometer has observed the 1 - 2 GHz radio emission of solar flares with unprecedented sensitivity. The number of detected decimeter type III bursts is greatly enhanced compared to observations by conventional spectrometers observing only one frequency at the time. The observations indicate a large number of electron beams propagating in dense plasmas. For the first time, we report weak, reversed drifting type III bursts at frequencies above simultaneous narrowband decimeter spikes. The type III bursts are reliable signatures of electron beams propagating downward in the corona, apparently away from the source of the spikes. The observations contradict the most popular spike model that places the spike sources at the footpoints of loops. Conspicuous also was an apparent bidirectional type U burst forming a fish-like pattern. It occurs simultaneously with an intense U-burst at 600-370 MHz observed in Tremsdorf. We suggest that it intermodulated with strong terrestrial interference ...

  19. Highly sensitive detection using microring resonator and nanopores

    Science.gov (United States)

    Bougot-Robin, K.; Hoste, J. W.; Le Thomas, N.; Bienstman, P.; Edel, J. B.

    2016-04-01

    One of the most significant challenges facing physical and biological scientists is the accurate detection and identification of single molecules in free-solution environments. The ability to perform such sensitive and selective measurements opens new avenues for a large number of applications in biological, medical and chemical analysis, where small sample volumes and low analyte concentrations are the norm. Access to information at the single or few molecules scale is rendered possible by a fine combination of recent advances in technologies. We propose a novel detection method that combines highly sensitive label-free resonant sensing obtained with high-Q microcavities and position control in nanoscale pores (nanopores). In addition to be label-free and highly sensitive, our technique is immobilization free and does not rely on surface biochemistry to bind probes on a chip. This is a significant advantage, both in term of biology uncertainties and fewer biological preparation steps. Through combination of high-Q photonic structures with translocation through nanopore at the end of a pipette, or through a solid-state membrane, we believe significant advances can be achieved in the field of biosensing. Silicon microrings are highly advantageous in term of sensitivity, multiplexing, and microfabrication and are chosen for this study. In term of nanopores, we both consider nanopore at the end of a nanopipette, with the pore being approach from the pipette with nanoprecise mechanical control. Alternatively, solid state nanopores can be fabricated through a membrane, supporting the ring. Both configuration are discussed in this paper, in term of implementation and sensitivity.

  20. High-speed and high-sensitivity displacement measurement with phase-locked low-coherence interferometry.

    Science.gov (United States)

    Manojlović, Lazo M; Zivanov, Miloš B; Slankamenac, Miloš P; Bajić, Jovan S; Stupar, Dragan Z

    2012-07-01

    A novel high-speed and high-sensitivity displacement measurement sensing system, based on the phase-locked low-coherence interferometry, is presented. The sensing system is realized by comprising the Michelson fiber-optic interferometer. In order to obtain quadrature signals at the interferometer outputs, a 3×3 fused silica fiber-optic directional coupler is used. Therefore, the usage of the interferometer phase modulation as well as the usage of the lock-in amplification has been avoided. In this way, the speed of such a realized sensing system is significantly increased in comparison with the standard phase-locked interferometric systems that can be found elsewhere in the literature. The bandwidth of the realized sensing system is limited by the first resonance frequency of the used piezo actuator to 4.6 kHz. The estimated noise floor in the displacement measurement is approximately 180  pm/√Hz.

  1. High Sensitive Precise 3D Accelerometer for Solar System Exploration with Unmanned Spacecrafts

    Science.gov (United States)

    Savenko, Y. V.; Demyanenko, P. O.; Zinkovskiy, Y. F.

    Solutions of several space and geophysical tasks require creating high sensitive precise accelerometers with sensitivity in order of 10 -13 g. These several tasks are following: inertial navigation of the Earth and Space; gravimetry nearby the Earth and into Space; geology; geophysics; seismology etc. Accelerometers (gravimeters and gradientmeters) with required sensitivity are not available now. The best accelerometers in the world have sensitivity worth on 4-5 orders. It has been developed a new class of fiber-optical sensors (FOS) with light pulse modulation. These sensors have super high threshold sensitivity and wide (up to 10 orders) dynamic range, and can be used as a base for creating of measurement units of physical values as 3D superhigh sensitive precise accelerometers of linear accelerations that is suitable for highest requirements. The principle of operation of the FOS is organically combined with a digital signal processing. It allows decreasing hardware of the accelerometer due to using a usual air-borne or space-borne computer; correcting the influence of natural, design, technological drawbacks of FOS on measured results; neutralising the influence of extraordinary situations available during using of FOS; decreasing the influence of internal and external destabilising factors (as for FOS), such as oscillation of environment temperature, instability of pendulum cycle frequency of sensitive element of the accelerometer etc. We were conducted a quantitative estimation of precise opportunities of analogue FOS in structure of fiber optical measuring devices (FOMD) for elementary FOMD with analogue FOS built on modern element basis of fiber optics (FO), at following assumptions: absolute parameter stability of devices of FOS measuring path; single transmission band of registration path; maximum possible inserted in optical fiber (OF) a radiated power. Even at such idealized assumptions, a calculated value in limit reached minimum inaccuracy of

  2. Highly Mass-Sensitive Thin Film Plate Acoustic Resonators (FPAR)

    Science.gov (United States)

    Arapan, Lilia; Alexieva, Gergana; Avramov, Ivan D.; Radeva, Ekaterina; Strashilov, Vesseline; Katardjiev, Ilia; Yantchev, Ventsislav

    2011-01-01

    The mass sensitivity of thin aluminum nitride (AlN) film S0 Lamb wave resonators is theoretically and experimentally studied. Theoretical predictions based on modal and finite elements method analysis are experimentally verified. Here, two-port 888 MHz synchronous FPARs are micromachined and subsequently coated with hexamethyl-disiloxane(HMDSO)-plasma-polymerized thin films of various thicknesses. Systematic data on frequency shift and insertion loss versus film thickness are presented. FPARs demonstrate high mass-loading sensitivity as well as good tolerance towards the HMDSO viscous losses. Initial measurements in gas phase environment are further presented. PMID:22163994

  3. Highly mass-sensitive thin film plate acoustic resonators (FPAR).

    Science.gov (United States)

    Arapan, Lilia; Alexieva, Gergana; Avramov, Ivan D; Radeva, Ekaterina; Strashilov, Vesseline; Katardjiev, Ilia; Yantchev, Ventsislav

    2011-01-01

    The mass sensitivity of thin aluminum nitride (AlN) film S0 Lamb wave resonators is theoretically and experimentally studied. Theoretical predictions based on modal and finite elements method analysis are experimentally verified. Here, two-port 888 MHz synchronous FPARs are micromachined and subsequently coated with hexamethyl-disiloxane(HMDSO)-plasma-polymerized thin films of various thicknesses. Systematic data on frequency shift and insertion loss versus film thickness are presented. FPARs demonstrate high mass-loading sensitivity as well as good tolerance towards the HMDSO viscous losses. Initial measurements in gas phase environment are further presented.

  4. Design and Fabrication of High Sensitive Piezoresistive MEMS Accelerometer

    Directory of Open Access Journals (Sweden)

    JOSHI A.B

    2008-04-01

    Full Text Available This paper addresses the design and fabrication of high sensitive single axis piezoresistive micro-accelerometer for 50 g application. MEMS based accelerometer structure comprise of flexure fixed at one end and having attached proof mass at other end. This structure is designed and simulated using Coventorware. The simulation results show the sensitivity of 4mV/g. The structure is fabricated in N type silicon (100 substrate using Silicon bulk micromachining. This paper also discuses the use of PECVD Si3N4 layer as a masking material for silicon micromachining and process flow for accelerometer.

  5. Cardiac troponins and high-sensitivity cardiac troponin assays.

    Science.gov (United States)

    Conrad, Michael J; Jarolim, Petr

    2014-03-01

    Measurement of circulating cardiac troponins I and T has become integral to the diagnosis of myocardial infarction. This article discusses the structure and function of the troponin complex and the release of cardiac troponin molecules from the injured cardiomyocyte into the circulation. An overview of current cardiac troponin assays and their classification according to sensitivity is presented. The diagnostic criteria, role, and usefulness of cardiac troponin for myocardial infarction are discussed. In addition, several examples are given of the usefulness of high-sensitivity cardiac troponin assays for short-term and long-term prediction of adverse events.

  6. Highly Mass-Sensitive Thin Film Plate Acoustic Resonators (FPAR

    Directory of Open Access Journals (Sweden)

    Ventsislav Yantchev

    2011-07-01

    Full Text Available The mass sensitivity of thin aluminum nitride (AlN film S0 Lamb wave resonators is theoretically and experimentally studied. Theoretical predictions based on modal and finite elements method analysis are experimentally verified. Here, two-port 888 MHz synchronous FPARs are micromachined and subsequently coated with hexamethyl-disiloxane(HMDSO-plasma-polymerized thin films of various thicknesses. Systematic data on frequency shift and insertion loss versus film thickness are presented. FPARs demonstrate high mass-loading sensitivity as well as good tolerance towards the HMDSO viscous losses. Initial measurements in gas phase environment are further presented.

  7. A Highly Sensitive Refractometric Sensor Based on Cascaded SiN Microring Resonators

    Directory of Open Access Journals (Sweden)

    Daniel Pergande

    2013-10-01

    Full Text Available We investigate a highly sensitive optical sensor based on two cascaded microring resonators exploiting the Vernier effect. The architecture consists of two microrings with a slight difference in their free spectral ranges. This allows the generation of the Vernier effect for achieving ultra-high sensitivities. The sensor chip was fabricated using a silicon nitride platform and characterized with isopropanol/ethanol mixtures. A sensitivity of 0.95 nm/% was found for isopropanol concentrations in ethanol ranging from 0% to 10%. Furthermore, a collection of measurements was carried out using aqueous sodium chloride (NaCl in solutions of different concentrations, confirming a high sensitivity of 10.3 nm/% and a bulk refractive index sensitivity of 6,317 nm/RIU. A limit of detection of 3.16 ´ 10−6 RIU was determined. These preliminary results show the potential features of cascaded silicon nitride microring resonators for real-time and free-label monitoring of biomolecules for a broad range of applications.

  8. A highly sensitive refractometric sensor based on cascaded SiN microring resonators.

    Science.gov (United States)

    Zamora, Vanessa; Lützow, Peter; Weiland, Martin; Pergande, Daniel

    2013-10-28

    We investigate a highly sensitive optical sensor based on two cascaded microring resonators exploiting the Vernier effect. The architecture consists of two microrings with a slight difference in their free spectral ranges. This allows the generation of the Vernier effect for achieving ultra-high sensitivities. The sensor chip was fabricated using a silicon nitride platform and characterized with isopropanol/ethanol mixtures. A sensitivity of 0.95 nm/% was found for isopropanol concentrations in ethanol ranging from 0% to 10%. Furthermore, a collection of measurements was carried out using aqueous sodium chloride (NaCl) in solutions of different concentrations, confirming a high sensitivity of 10.3 nm/% and a bulk refractive index sensitivity of 6,317 nm/RIU. A limit of detection of 3.16 × 10(-6) RIU was determined. These preliminary results show the potential features of cascaded silicon nitride microring resonators for real-time and free-label monitoring of biomolecules for a broad range of applications.

  9. Large-sensitive-area superconducting nanowire single-photon detector at 850 nm with high detection efficiency

    CERN Document Server

    Li, Hao; You, Lixing; Yang, Xiaoyan; Zhang, Weijun; Liu, Xiaoyu; Chen, Sijing; Wang, Zhen; Xie, Xiaoming

    2015-01-01

    Satellite-ground quantum communication requires single-photon detectors of 850-nm wavelength with both high detection efficiency and large sensitive area. We developed superconducting nanowire single-photon detectors (SNSPDs) on one-dimensional photonic crystals, which acted as optical cavities to enhance the optical absorption, with a sensitive-area diameter of 50 um. The fabricated multimode fiber coupled NbN SNSPDs exhibited a maximum system detection efficiency (DE) of up to 82% and a DE of 78% at a dark count rate of 100 Hz at 850-nm wavelength as well as a system jitter of 105 ps.

  10. Turbulence velocity profiling for high sensitivity and vertical-resolution atmospheric characterization with Stereo-SCIDAR

    Science.gov (United States)

    Osborn, J.; Butterley, T.; Townson, M. J.; Reeves, A. P.; Morris, T. J.; Wilson, R. W.

    2017-02-01

    As telescopes become larger, into the era of ˜40 m Extremely Large Telescopes, the high-resolution vertical profile of the optical turbulence strength is critical for the validation, optimization and operation of optical systems. The velocity of atmospheric optical turbulence is an important parameter for several applications including astronomical adaptive optics systems. Here, we compare the vertical profile of the velocity of the atmospheric wind above La Palma by means of a comparison of Stereo-SCIntillation Detection And Ranging (Stereo-SCIDAR) with the Global Forecast System models and nearby balloon-borne radiosondes. We use these data to validate the automated optical turbulence velocity identification from the Stereo-SCIDAR instrument mounted on the 2.5 m Isaac Newton Telescope, La Palma. By comparing these data we infer that the turbulence velocity and the wind velocity are consistent and that the automated turbulence velocity identification of the Stereo-SCIDAR is precise. The turbulence velocities can be used to increase the sensitivity of the turbulence strength profiles, as weaker turbulence that may be misinterpreted as noise can be detected with a velocity vector. The turbulence velocities can also be used to increase the altitude resolution of a detected layer, as the altitude of the velocity vectors can be identified to a greater precision than the native resolution of the system. We also show examples of complex velocity structure within a turbulent layer caused by wind shear at the interface of atmospheric zones.

  11. High Sensitivity Very Low Frequency Receiver for Earthquake Data Acquisition.

    Science.gov (United States)

    Munir, A.; Najmurrokhman, A.

    2017-03-01

    high sensitivity very low frequency (VLF) receiver is developed based on AD744 monolithic operational amplifier (Op-Amp) for earthquake data acquisition. In research related natural phenomena such as atmospheric noise, lightning and earthquake, a VLF receiver particularly with high sensitivity is utterly required due to the low power of VLF wave signals received by the antenna. The developed receiver is intended to have high sensitivity reception for the signals in frequency range of 10-30kHz allocated for earthquake observation. The VLF receiver which is portably designed is also equipped with an output port connectable to the soundcard of personal computer for further data acquisition. After obtaining the optimum design, the hardware realization is implemented on a printed circuit board (PCB) for experimental characterization. It shows that the sensitivity of realized VLF receiver is almost linear in the predefined frequency range for the input signals lower than -12dBm and to be quadratic for the higher level input signals.

  12. High-accurate optical vector analysis based on optical single-sideband modulation

    Science.gov (United States)

    Xue, Min; Pan, Shilong

    2016-11-01

    Most of the efforts devoted to the area of optical communications were on the improvement of the optical spectral efficiency. Varies innovative optical devices are thus developed to finely manipulate the optical spectrum. Knowing the spectral responses of these devices, including the magnitude, phase and polarization responses, is of great importance for their fabrication and application. To achieve high-resolution characterization, optical vector analyzers (OVAs) based on optical single-sideband (OSSB) modulation have been proposed and developed. Benefiting from the mature and highresolution microwave technologies, the OSSB-based OVA can potentially achieve a resolution of sub-Hz. However, the accuracy is restricted by the measurement errors induced by the unwanted first-order sideband and the high-order sidebands in the OSSB signal, since electrical-to-optical conversion and optical-to-electrical conversion are essentially required to achieve high-resolution frequency sweeping and extract the magnitude and phase information in the electrical domain. Recently, great efforts have been devoted to improve the accuracy of the OSSB-based OVA. In this paper, the influence of the unwanted-sideband induced measurement errors and techniques for implementing high-accurate OSSB-based OVAs are discussed.

  13. Optical glass with tightest refractive index and dispersion tolerances for high-end optical designs

    Science.gov (United States)

    Jedamzik, R.; Reichel, S.; Hartmann, P.

    2014-03-01

    In high end optical designs the quality of the optical system not only depends on the chosen optical glasses but also on the available refractive index and Abbe number tolerances. The primary optical design is based on datasheet values of the refractive index and Abbe number. In general the optical position of the delivered glass will deviate from the catalog values by given tolerances due to production tolerances. Therefore in many cases the final optical design needs to be modified based on real glass data. Tighter refractive index and Abbe number tolerances can greatly reduce this additional amount of work. The refractive index and Abbe number of an optical glass is a function of the chemical composition and the annealing process. Tight refractive index tolerances require not only a close control and high reliability of the melting and fine annealing process but also best possible material data. These data rely on high accuracy measurement and accurate control during mass production. Modern melting and annealing procedure do not only enable tight index tolerances but also a high homogeneity of the optical properties. Recently SCHOTT was able to introduce the tightest available refractive index and Abbe number tolerance available in the market: step 0.5 meaning a refractive index tolerance of +/- 0.0001 and an Abbe number tolerance of +/- 0.1%. This presentation describes how the refractive index depends on the glass composition and annealing process and describes the requirements to get to this tightest refractive index and Abbe number tolerance.

  14. Alternative high-resolution lithographic technologies for optical applications

    Science.gov (United States)

    Zeitner, Uwe D.; Weichelt, Tina; Bourgin, Yannick; Kinder, Robert

    2016-03-01

    Modern optical applications have special demands on the lithographic fabrication technologies. This relates to the lateral shape of the structures as well as to their three dimensional surface profile. On the other hand optical nano-structures are often periodic which allows for the use of dedicated lithographic exposure principles. The paper briefly reviews actual developments in the field of optical nano-structure generation. Special emphasis will be given to two technologies: electron-beam lithography based on a flexible cell-projection method and the actual developments in diffractive mask aligner lithography. Both offer a cost effective fabrication alternative for high resolution structures or three-dimensional optical surface profiles.

  15. Recent Advances in Ultra-High-Speed Optical Signal Processing

    DEFF Research Database (Denmark)

    Mulvad, Hans Christian Hansen; Palushani, Evarist; Hu, Hao;

    2012-01-01

    We review recent advances in the optical signal processing of ultra-high-speed serial data signals up to 1.28 Tbit/s, with focus on applications of time-domain optical Fourier transformation. Experimental methods for the generation of symbol rates up to 1.28 Tbaud are also described....

  16. Highly Sensitive Liquid Core Temperature Sensor Based on Multimode Interference Effects

    Directory of Open Access Journals (Sweden)

    Miguel A. Fuentes-Fuentes

    2015-10-01

    Full Text Available A novel fiber optic temperature sensor based on a liquid-core multimode interference device is demonstrated. The advantage of such structure is that the thermo-optic coefficient (TOC of the liquid is at least one order of magnitude larger than that of silica and this, combined with the fact that the TOC of silica and the liquid have opposite signs, provides a liquid-core multimode fiber (MMF highly sensitive to temperature. Since the refractive index of the liquid can be easily modified, this allows us to control the modal properties of the liquid-core MMF at will and the sensor sensitivity can be easily tuned by selecting the refractive index of the liquid in the core of the device. The maximum sensitivity measured in our experiments is 20 nm/°C in the low-temperature regime up to 60 °C. To the best of our knowledge, to date, this is the largest sensitivity reported for fiber-based MMI temperature sensors.

  17. Near-infrared grating-assisted SPR optical fiber sensors: design rules for ultimate refractometric sensitivity.

    Science.gov (United States)

    Caucheteur, Christophe; Voisin, Valérie; Albert, Jacques

    2015-02-09

    Plasmonic optical fiber sensors are continuously developed for (bio)chemical sensing purposes. Recently, surface plasmon resonance (SPR) generation was achieved in gold-coated tilted fiber Bragg gratings (TFBGs). These sensors probe the surrounding medium with near-infrared narrowband resonances, which enhances both the penetration depth of the evanescent field in the external medium and the wavelength resolution of the interrogation. They constitute a unique configuration to probe all the fiber cladding modes individually. We use them to analyze the modal distribution of gold-coated telecommunication-grade optical fibers immersed in aqueous solutions. Theoretical investigations with a finite-difference complex mode solver are confirmed by experimental data obtained on TFBGs. We show that the refractometric sensitivity varies with the mode order and that the global SPR envelope shift in response to surrounding refractive index (SRI) changes higher than 1e-2 RIU (refractive index unit) can be ~25% bigger than the local SPR mode shift arising from SRI changes limited to 1e-4 RIU. We bring clear evidence that the optimum gold thickness for SPR generation lies in the range between 50 and 70 nm while a cladding diameter decrease from 125 µm to 80 µm enhances the refractometric sensitivity by ~20%. Finally, we demonstrate that the ultimate refractometric sensitivity of cladding modes is ~550 nm/RIU when they are probed by gold-coated TFBGs.

  18. Optical Processing of High Dimensionality Signals

    DEFF Research Database (Denmark)

    Da Ros, Francesco

    signal processing, including wavelength conversion, optical phase conjugation (OPC), and signal regeneration. This project focuses precisely on the applications of OPAs for all-optical signal processing with a two-fold focus: on the one hand, processing the advanced modulation formats required......) waveguides, are investigated. The limits of parametric amplification for 16-quadrature amplitude modulation (QAM) signals are first characterized. The acquired knowledge is then applied to the design of a black-box OPC-device used to provide Kerr nonlinearity compensation for a 5-channel polarization......-division multiplexing (PDM) 16-QAM signal at 1.12 Tbps with significant improvements in received signal quality. Furthermore, the first demonstration of phase regeneration for binary phase-shift keying (BPSK) signals using the silicon platform is presented. The silicon-based OPA relies on a novel design where a reverse...

  19. Fast and sensitive optical toxicity bioassay based on dual wavelength analysis of bacterial ferricyanide reduction kinetics.

    Science.gov (United States)

    Pujol-Vila, F; Vigués, N; Díaz-González, M; Muñoz-Berbel, X; Mas, J

    2015-05-15

    Global urban and industrial growth, with the associated environmental contamination, is promoting the development of rapid and inexpensive general toxicity methods. Current microbial methodologies for general toxicity determination rely on either bioluminescent bacteria and specific medium solution (i.e. Microtox(®)) or low sensitivity and diffusion limited protocols (i.e. amperometric microbial respirometry). In this work, fast and sensitive optical toxicity bioassay based on dual wavelength analysis of bacterial ferricyanide reduction kinetics is presented, using Escherichia coli as a bacterial model. Ferricyanide reduction kinetic analysis (variation of ferricyanide absorption with time), much more sensitive than single absorbance measurements, allowed for direct and fast toxicity determination without pre-incubation steps (assay time=10 min) and minimizing biomass interference. Dual wavelength analysis at 405 (ferricyanide and biomass) and 550 nm (biomass), allowed for ferricyanide monitoring without interference of biomass scattering. On the other hand, refractive index (RI) matching with saccharose reduced bacterial light scattering around 50%, expanding the analytical linear range in the determination of absorbent molecules. With this method, different toxicants such as metals and organic compounds were analyzed with good sensitivities. Half maximal effective concentrations (EC50) obtained after 10 min bioassay, 2.9, 1.0, 0.7 and 18.3 mg L(-1) for copper, zinc, acetic acid and 2-phenylethanol respectively, were in agreement with previously reported values for longer bioassays (around 60 min). This method represents a promising alternative for fast and sensitive water toxicity monitoring, opening the possibility of quick in situ analysis.

  20. Biosensor based on excessively tilted fiber grating in thin-cladding optical fiber for sensitive and selective detection of low glucose concentration.

    Science.gov (United States)

    Luo, Binbin; Yan, Zhijun; Sun, Zhongyuan; Liu, Yong; Zhao, Mingfu; Zhang, Lin

    2015-12-14

    We report a highly sensitive, high Q-factor, label free and selective glucose sensor by using excessively tilted fiber grating (Ex-TFG) inscribed in the thin-cladding optical fiber (TCOF). Glucose oxidase (GOD) was covalently immobilized on optical fiber surface and the effectiveness of GOD immobilization was investigated by the fluorescence microscopy and highly accurate spectral interrogation method. In contrast to the long period grating (LPG) and optical fiber (OF) surface Plasmon resonance (SPR) based glucose sensors, the Ex-TFG configuration has merits of nearly independent cross sensitivity of the environmental temperature, simple fabrication method (no noble metal deposition or cladding etching) and high detection accuracy (or Q-factor). Our experimental results have shown that Ex-TFG in TCOF based sensor has a reliable and fast detection for the glucose concentration as low as 0.1~2.5mg/ml and a high sensitivity of ~1.514 nm·(mg/ml)⁻¹, which the detection accuracy is ~0.2857 nm⁻¹ at pH 5.2, and the limit of detection (LOD) is 0.013~0.02 mg/ml at the pH range of 5.2~7.4 by using an optical spectrum analyzer with a resolution of 0.02 nm.

  1. Application of Single-Mode Fiber-Coupled Receivers in Optical Satellite to High-Altitude Platform Communications

    Directory of Open Access Journals (Sweden)

    Oswald Wallner

    2008-05-01

    Full Text Available In a free-space optical communication system employing fiber-optic components, the phasefront distortions induced by atmospheric turbulence limit the efficiency with which the laser beam is coupled into a single-mode fiber. We analyze different link scenarios including a geostationary (GEO satellite, a high-altitude platform (HAP, and an optical ground station (OGS. Single-mode coupled optically preamplified receivers allow for efficient suppression of background noise and highly sensitive detection. While GEO-to-OGS communication suffers from atmospheric turbulence, we demonstrate that GEO-to-HAP communication allows for close to diffraction-limited performance when applying tip-tilt correction.

  2. Application of Single-Mode Fiber-Coupled Receivers in Optical Satellite to High-Altitude Platform Communications

    Directory of Open Access Journals (Sweden)

    Fidler Franz

    2008-01-01

    Full Text Available Abstract In a free-space optical communication system employing fiber-optic components, the phasefront distortions induced by atmospheric turbulence limit the efficiency with which the laser beam is coupled into a single-mode fiber. We analyze different link scenarios including a geostationary (GEO satellite, a high-altitude platform (HAP, and an optical ground station (OGS. Single-mode coupled optically preamplified receivers allow for efficient suppression of background noise and highly sensitive detection. While GEO-to-OGS communication suffers from atmospheric turbulence, we demonstrate that GEO-to-HAP communication allows for close to diffraction-limited performance when applying tip-tilt correction.

  3. Are Inflationary Predictions Sensitive to Very High Energy Physics?

    CERN Document Server

    Burgess, C P; Lemieux, F; Holman, R

    2003-01-01

    It has been proposed that the successful inflationary description of density perturbations on cosmological scales is sensitive to the details of physics at extremely high (trans-Planckian) energies. We test this proposal by examining how inflationary predictions depend on higher-energy scales within a simple model where the higher-energy physics is well understood. We find the best of all possible worlds: inflationary predictions are robust against the vast majority of high-energy effects, but can be sensitive to some effects in certain circumstances, in a way which does not violate ordinary notions of decoupling. This implies both that the comparison of inflationary predictions with CMB data is meaningful, and that it is also worth searching for small deviations from the standard results in the hopes of learning about very high energies.

  4. Design of highly sensitive multichannel bimetallic photonic crystal fiber biosensor

    Science.gov (United States)

    Hameed, Mohamed Farhat O.; Alrayk, Yassmin K. A.; Shaalan, Abdelhamid A.; El Deeb, Walid S.; Obayya, Salah S. A.

    2016-10-01

    A design of a highly sensitive multichannel biosensor based on photonic crystal fiber is proposed and analyzed. The suggested design has a silver layer as a plasmonic material coated by a gold layer to protect silver oxidation. The reported sensor is based on detection using the quasi transverse electric (TE) and quasi transverse magnetic (TM) modes, which offers the possibility of multichannel/multianalyte sensing. The numerical results are obtained using a finite element method with perfect matched layer boundary conditions. The sensor geometrical parameters are optimized to achieve high sensitivity for the two polarized modes. High-refractive index sensitivity of about 4750 nm/RIU (refractive index unit) and 4300 nm/RIU with corresponding resolutions of 2.1×10-5 RIU, and 2.33×10-5 RIU can be obtained according to the quasi TM and quasi TE modes of the proposed sensor, respectively. Further, the reported design can be used as a self-calibration biosensor within an unknown analyte refractive index ranging from 1.33 to 1.35 with high linearity and high accuracy. Moreover, the suggested biosensor has advantages in terms of compactness and better integration of microfluidics setup, waveguide, and metallic layers into a single structure.

  5. Sensitivity of HAWC to high-mass dark matter annihilations

    Science.gov (United States)

    Abeysekara, A. U.; Alfaro, R.; Alvarez, C.; Álvarez, J. D.; Arceo, R.; Arteaga-Velázquez, J. C.; Ayala Solares, H. A.; Barber, A. S.; Baughman, B. M.; Bautista-Elivar, N.; Becerra Gonzalez, J.; Belmont, E.; BenZvi, S. Y.; Berley, D.; Bonilla Rosales, M.; Braun, J.; Caballero-Lopez, R. A.; Caballero-Mora, K. S.; Carramiñana, A.; Castillo, M.; Cotti, U.; Cotzomi, J.; de la Fuente, E.; De León, C.; DeYoung, T.; Diaz Hernandez, R.; Diaz-Cruz, L.; Díaz-Vélez, J. C.; Dingus, B. L.; DuVernois, M. A.; Ellsworth, R. W.; Fiorino, D. W.; Fraija, N.; Galindo, A.; Garfias, F.; González, M. M.; Goodman, J. A.; Grabski, V.; Gussert, M.; Hampel-Arias, Z.; Harding, J. P.; Hui, C. M.; Hüntemeyer, P.; Imran, A.; Iriarte, A.; Karn, P.; Kieda, D.; Kunde, G. J.; Lara, A.; Lauer, R. J.; Lee, W. H.; Lennarz, D.; León Vargas, H.; Linares, E. C.; Linnemann, J. T.; Longo, M.; Luna-Garcia, R.; Marinelli, A.; Martinez, H.; Martinez, O.; Martínez-Castro, J.; Matthews, J. A. J.; McEnery, J.; Mendoza Torres, E.; Miranda-Romagnoli, P.; Moreno, E.; Mostafá, M.; Nellen, L.; Newbold, M.; Noriega-Papaqui, R.; Oceguera-Becerra, T.; Patricelli, B.; Pelayo, R.; Pérez-Pérez, E. G.; Pretz, J.; Rivière, C.; Rosa-González, D.; Ryan, J.; Salazar, H.; Salesa, F.; Sanchez, F. E.; Sandoval, A.; Schneider, M.; Silich, S.; Sinnis, G.; Smith, A. J.; Sparks Woodle, K.; Springer, R. W.; Taboada, I.; Toale, P. A.; Tollefson, K.; Torres, I.; Ukwatta, T. N.; Villaseñor, L.; Weisgarber, T.; Westerhoff, S.; Wisher, I. G.; Wood, J.; Yodh, G. B.; Younk, P. W.; Zaborov, D.; Zepeda, A.; Zhou, H.; Abazajian, K. N.; Milagro Collaboration

    2014-12-01

    The High Altitude Water Cherenkov (HAWC) observatory is a wide field-of-view detector sensitive to gamma rays of 100 GeV to a few hundred TeV. Located in central Mexico at 19° North latitude and 4100 m above sea level, HAWC will observe gamma rays and cosmic rays with an array of water Cherenkov detectors. The full HAWC array is scheduled to be operational in Spring 2015. In this paper, we study the HAWC sensitivity to the gamma-ray signatures of high-mass (multi-TeV) dark matter annihilation. The HAWC observatory will be sensitive to diverse searches for dark matter annihilation, including annihilation from extended dark matter sources, the diffuse gamma-ray emission from dark matter annihilation, and gamma-ray emission from nonluminous dark matter subhalos. Here we consider the HAWC sensitivity to a subset of these sources, including dwarf galaxies, the M31 galaxy, the Virgo cluster, and the Galactic center. We simulate the HAWC response to gamma rays from these sources in several well-motivated dark matter annihilation channels. If no gamma-ray excess is observed, we show the limits HAWC can place on the dark matter cross section from these sources. In particular, in the case of dark matter annihilation into gauge bosons, HAWC will be able to detect a narrow range of dark matter masses to cross sections below thermal. HAWC should also be sensitive to nonthermal cross sections for masses up to nearly 1000 TeV. The constraints placed by HAWC on the dark matter cross section from known sources should be competitive with current limits in the mass range where HAWC has similar sensitivity. HAWC can additionally explore higher dark matter masses than are currently constrained.

  6. Attonewton force detection using microspheres in a dual-beam optical trap in high vacuum

    CERN Document Server

    Ranjit, Gambhir; Stutz, Jordan H; Cunningham, Mark; Geraci, Andrew A

    2015-01-01

    We describe the implementation of laser-cooled silica microspheres as force sensors in a dual-beam optical dipole trap in high vacuum. Using this system we have demonstrated trap lifetimes exceeding several days, attonewton force detection capability, and wide tunability in trapping and cooling parameters. Measurements have been performed with charged and neutral beads to calibrate the sensitivity of the detector. This work establishes the suitability of dual beam optical dipole traps for precision force measurement in high vacuum with long averaging times, and enables future applications including the study of gravitational inverse square law violations at short range, Casimir forces, acceleration sensing, and quantum opto-mechanics.

  7. Immobilized fluorescent dyes for sensitive pH measurements on enamel surfaces with fiber optics

    Science.gov (United States)

    Rumphorst, A.; Seeger, Stefan; Duschner, H.

    1996-01-01

    Information on the pH directly on surfaces of dental enamel is an important aspect in research on tooth decay. As an alternative to pH-electrodes our approach to the problem is the optical determination of pH by pH sensitive fluorescent dyes immobilized to tooth surfaces. In this study a model for measuring pH either on aminated cellulose substrates or on enamel (in vitro) with a fluorescein type dye is presented. The experimental realization is a fiber optic sensor with a nitrogen-pumped dye laser system and photodiode for the detection of the emitted fluorescence light. The surface pH values in the range between 4 and 7 were derived from the ratios of the excitation bands at 490 nm and 460 nm.

  8. H.sub.2O doped WO.sub.3, ultra-fast, high-sensitivity hydrogen sensors

    Science.gov (United States)

    Liu, Ping; Tracy, C. Edwin; Pitts, J. Roland; Lee, Se-Hee

    2011-03-22

    An ultra-fast response, high sensitivity structure for optical detection of low concentrations of hydrogen gas, comprising: a substrate; a water-doped WO.sub.3 layer coated on the substrate; and a palladium layer coated on the water-doped WO.sub.3 layer.

  9. Design and performance of ultra-high-density optical fiber cable with rollable optical fiber ribbons

    Science.gov (United States)

    Hogari, Kazuo; Yamada, Yusuke; Toge, Kunihiro

    2010-08-01

    This paper proposes a novel ultra-high-density optical fiber cable that employs rollable optical fiber ribbons. The cable has great advantages in terms of cable weight and diameter, and fiber splicing workability. Moreover, it will be easy to install in a small space in underground ducts and on residential and business premises. The structural design of the rollable optical fiber ribbon is evaluated theoretically and experimentally, and an optimum adhesion pitch P in the longitudinal direction is obtained. In addition, we examined the performance of ultra-high-density cables with a small diameter that employ rollable optical fiber ribbons and bending-loss insensitive optical fibers. The transmission, mechanical and mid-span access performance of these cables was confirmed to be excellent.

  10. Strategies to Improve the Accuracy of Mars-GRAM Sensitivity Studies at Large Optical Depths

    Science.gov (United States)

    Justh, Hilary L.; Justus, Carl G.; Badger, Andrew M.

    2009-01-01

    The Mars Global Reference Atmospheric Model (Mars-GRAM) is an engineering-level atmospheric model widely used for diverse mission applications. Mars-GRAM s perturbation modeling capability is commonly used, in a Monte-Carlo mode, to perform high fidelity engineering end-to-end simulations for entry, descent, and landing (EDL). It has been discovered during the Mars Science Laboratory (MSL) site selection process that Mars-GRAM when used for sensitivity studies for MapYear=0 and large optical depth values such as tau=3 is less than realistic. A comparison study between Mars atmospheric density estimates from Mars- GRAM and measurements by Mars Global Surveyor (MGS) has been undertaken for locations of varying latitudes, Ls, and LTST on Mars. The preliminary results from this study have validated the Thermal Emission Spectrometer (TES) limb data. From the surface to 80 km altitude, Mars- GRAM is based on the NASA Ames Mars General Circulation Model (MGCM). MGCM results that were used for Mars-GRAM with MapYear=0 were from a MGCM run with a fixed value of tau=3 for the entire year at all locations. Unrealistic energy absorption by uniform atmospheric dust leads to an unrealistic thermal energy balance on the polar caps. The outcome is an inaccurate cycle of condensation/sublimation of the polar caps and, as a consequence, an inaccurate cycle of total atmospheric mass and global-average surface pressure. Under an assumption of unchanged temperature profile and hydrostatic equilibrium, a given percentage change in surface pressure would produce a corresponding percentage change in density at all altitudes. Consequently, the final result of a change in surface pressure is an imprecise atmospheric density at all altitudes. To solve this pressure-density problem, a density factor value was determined for tau=.3, 1 and 3 that will adjust the input values of MGCM MapYear 0 pressure and density to achieve a better match of Mars-GRAM MapYear=0 with MapYears 1 and 2 MGCM output

  11. Automated detection of chorio-scleral interface using polarization-sensitive optical coherence tomography

    Science.gov (United States)

    Duan, Lian; Yamanari, Masahiro; Yasuno, Yoshiaki

    2012-01-01

    A polarization sensitive optical coherence tomography based automated algorithm for segmentation of the chorio-scleral interface is presented. The algorithm employs a two-step segmentation approach. At first, local birefringence based segmentation with low precision is performed to roughly distinguish the choroid and sclera. Successively, a depth oriented slope fitting to phase retardation is applied in both the choroid and sclera. The interface is determined as the cross-point of the two phase retardation slope lines. The algorithm shows potential for functional, objective, and volumetric choroid thickness measurement.

  12. Imaging of human breast tissue using polarization sensitive optical coherence tomography

    Science.gov (United States)

    Verma, Y.; Gautam, M.; Divakar Rao, K.; Swami, M. K.; Gupta, P. K.

    2011-12-01

    We report a study on the use of polarization sensitive optical coherence tomography (PSOCT) for discriminating malignant (invasive ductal carcinoma), benign (fibroadenoma) and normal (adipocytes) breast tissue sites. The results show that while conventional OCT, that utilizes only the intensity of light back-scattered from tissue microstructures, is able to discriminate breast tissues as normal (adipocytes) and abnormal (malignant and benign) tissues, PS-OCT helps in discriminating between malignant and benign tissue sites also. The estimated values of birefringence obtained from the PSOCT imaging show that benign breast tissue samples have significantly higher birefringence as compared to the malignant tissue samples.

  13. X-ray-sensitive storage phosphors with the optically stable luminescent centres

    CERN Document Server

    Gorin, G B; Zvezdova, N P; Kochubey, D I; Sedova, Y G; Kochubey, D I; Kulipanov, G N; Lyakh, V V; Pindyurin, V F

    2000-01-01

    NaCl, KCl, KBr and LiF crystals doped by In, Tl, Ni, Pd and Ca were investigated as X-ray-sensitive materials. Influence of the way of doping of an impurity and growing of a crystal on such parameters of a material as: sensitivity to ionising radiation; radiative, optical and thermal stability of the image, obtained after an irradiation is investigated. As a result of the work, media for recording of the X-ray images are developed. These allow to reproduce the images in a mode of a photoluminescence. Spatial resolution and the dynamic range of registration of the developed materials concede to similar parameters of commercial storage luminophores like 'Image Plates' based on BaFBr : La. At the same time, as distinct from 'Image Plates', the developed radiophotoluminophores allow a long storage and multiple readout of the information recorded.

  14. Sensitivity-enhanced temperature sensor with cascaded fiber optic Sagnac interferometers based on Vernier-effect

    Science.gov (United States)

    Shao, Li-Yang; Luo, Yuan; Zhang, Zhiyong; Zou, Xihua; Luo, Bin; Pan, Wei; Yan, Lianshan

    2015-02-01

    A novel fiber optic temperature sensor has been proposed and experimentally demonstrated with ~9 times sensitivity enhancement by using two cascaded Sagnac interferometers. These two Sagnac interferometers consist of the same type of polarization maintaining fibers with slightly different lengths. The working principle is analogous to a Vernier scale. One interferometer acts as filter, while the other is for temperature sensing. The envelope of the cascaded sensor shifts much more than single one with a certain enhancement factor, which related to the free space range difference between the filter and sensor interferometers. Experimental results show that the temperature sensitivity is enhanced from -1.46 nm/°C based on single Sagnac configuration to -13.36 nm/°C.

  15. Test of the notch technique for determining the radial sensitivity of the optical model potential

    CERN Document Server

    Yang, Lei; Jia, Hui-ming; Xu, Xin-Xing; Ma, Nan-Ru; Sun, Li-Jie; Yang, Feng; Zhang, Huan-Qiao; Li, Zu-Hua; Wang, Dong-Xi

    2015-01-01

    Detailed investigations on the notch technique are performed on the ideal data generated by the optical model potential parameters extracted from the 16O+208Pb system at the laboratory energy of 129.5 MeV, to study the sensitivities of this technique on the model parameters as well as the experimental data. It is found that, for the perturbation parameters, a sufficient large reduced fraction and an appropriate small perturbation width are necessary to determine the accurate radial sensitivity; while for the potential parameters, almost no dependence was observed. For the experimental measurements, the number of data points has little influence for the heavy target system, and the relative inner information of the nuclear potential can be derived when the measurement extended to a lower cross section.

  16. Enhancing the limiting sensitivity of optical/infrared interferometry with natural guide star adaptive optics: happy couples or bad bed-fellows?

    Science.gov (United States)

    Rea, Alexander D.; Haniff, Christopher A.

    2012-07-01

    Enhancing the limiting sensitivity of optical/infrared interferometry is one of the "holy grails" of interferometric research. While the use of adaptive optics is in principle attractive, a number of issues suggest that its ability to enhance the sensitivity of ground-based arrays is less clear. Indeed, the ultimate sensitivity of an array may be limited by any of the multiple active and photon-hungry subsystems that comprise its whole. In this paper we investigate the limiting sensitivity of interferometer arrays using unit telescopes of moderate size (i.e. with D <= 4 m) equipped with natural guide star adaptive optics systems. We focus on how to realise the best limiting sensitivity for observations in the near-infrared. We nd that for Vega-type targets, i.e. those that have similar magnitudes at all wavelengths, the use of an adaptive optics system can provide enchancements in limiting sensitivity of up to 1.5 magnitudes. However, for redder targets this improvement can decrease dramatically, and very similar sensitivity (Δmlimiting <= 0.5) can be obtained with arrays using 1.5m-class apertures and tip-tilt correction alone.

  17. Development of High Sensitivity Nuclear Emulsion and Fine Grained Emulsion

    Energy Technology Data Exchange (ETDEWEB)

    Kawahara, H.; Asada, T. [Department of Physics, Nagoya University, Nagoya 464-8602 (Japan); Naka, T. [Institute of Advanced Research, Nagoya University (Japan); Naganawa, N.; Kuwabara, K.; Nakamura, M. [Department of Physics, Nagoya University, Nagoya 464-8602 (Japan)

    2014-08-15

    Nuclear emulsion is a particle detector having high spacial resolution and angular resolution. It became useful for large statistics experiment thanks to the development of automatic scanning system. In 2010, a facility for emulsion production was introduced and R and D of nuclear emulsion began at Nagoya university. In this paper, we present results of development of the high sensitivity emulsion and fine grained emulsion for dark matter search experiment. Improvement of sensitivity is achieved by raising density of silver halide crystals and doping well-adjusted amount of chemicals. Production of fine grained emulsion was difficult because of unexpected crystal condensation. By mixing polyvinyl alcohol (PVA) to gelatin as a binder, we succeeded in making a stable fine grained emulsion.

  18. Highly sensitive troponin T in patients with acute ischemic stroke

    DEFF Research Database (Denmark)

    Jensen, J K; Ueland, T; Aukrust, P;

    2012-01-01

    in decedents than in survivors. After adjustment for stroke severity, C-reactive protein, age, NT-proBNP and prior heart and/or renal failure, hsTnT levels were not a significant predictor of long-term all-cause or cardiovascular mortality. Conclusion: Elevated levels of hsTnT are frequently present......Background: Newly developed troponin assays have superior diagnostic and prognostic performance in acute coronary syndrome (ACS), when compared to conventional troponin assays; however, highly sensitive troponin has not been evaluated in patients with acute ischemic stroke. Methods: Highly...... sensitive troponin T (hsTnT) was measured daily during the first 4 days in 193 consecutive patients with acute ischemic stroke without overt ACS or atrial fibrillation. The patients were previously tested normal with a fourth-generation TnT assay. The patients were followed for 47 months, with all...

  19. Depth profilometry via multiplexed optical high-coherence interferometry

    National Research Council Canada - National Science Library

    Kazemzadeh, Farnoud; Wong, Alexander; Behr, Bradford B; Hajian, Arsen R

    2015-01-01

    ... such as defect detection, corrosion assessment, and dental assessment to name a few. In this study, we investigate the feasibility of depth profilometry using an Multiplexed Optical High-coherence Interferometry MOHI instrument...

  20. Decay of high order optical vortices in anisotropic nonlinear optical media

    DEFF Research Database (Denmark)

    Mamaev, A.V.; Saffman, M.; Zozulya, A.A.

    1997-01-01

    We present an experimental and theoretical study of the decay of high order optical vortices in media with an anisotropic nonlocal nonlinearity. Vortices with charge n decay into an aligned array of n vortices of unit charge.......We present an experimental and theoretical study of the decay of high order optical vortices in media with an anisotropic nonlocal nonlinearity. Vortices with charge n decay into an aligned array of n vortices of unit charge....

  1. Structural Glycomic Analyses at High Sensitivity: A Decade of Progress

    Science.gov (United States)

    Alley, William R.; Novotny, Milos V.

    2013-06-01

    The field of glycomics has recently advanced in response to the urgent need for structural characterization and quantification of complex carbohydrates in biologically and medically important applications. The recent success of analytical glycobiology at high sensitivity reflects numerous advances in biomolecular mass spectrometry and its instrumentation, capillary and microchip separation techniques, and microchemical manipulations of carbohydrate reactivity. The multimethodological approach appears to be necessary to gain an in-depth understanding of very complex glycomes in different biological systems.

  2. Highly Sensitive Flexible Magnetic Sensor Based on Anisotropic Magnetoresistance Effect.

    Science.gov (United States)

    Wang, Zhiguang; Wang, Xinjun; Li, Menghui; Gao, Yuan; Hu, Zhongqiang; Nan, Tianxiang; Liang, Xianfeng; Chen, Huaihao; Yang, Jia; Cash, Syd; Sun, Nian-Xiang

    2016-11-01

    A highly sensitive flexible magnetic sensor based on the anisotropic magnetoresistance effect is fabricated. A limit of detection of 150 nT is observed and excellent deformation stability is achieved after wrapping of the flexible sensor, with bending radii down to 5 mm. The flexible AMR sensor is used to read a magnetic pattern with a thickness of 10 μm that is formed by ferrite magnetic inks.

  3. Magneto-optical system for high speed real time imaging

    Science.gov (United States)

    Baziljevich, M.; Barness, D.; Sinvani, M.; Perel, E.; Shaulov, A.; Yeshurun, Y.

    2012-08-01

    A new magneto-optical system has been developed to expand the range of high speed real time magneto-optical imaging. A special source for the external magnetic field has also been designed, using a pump solenoid to rapidly excite the field coil. Together with careful modifications of the cryostat, to reduce eddy currents, ramping rates reaching 3000 T/s have been achieved. Using a powerful laser as the light source, a custom designed optical assembly, and a high speed digital camera, real time imaging rates up to 30 000 frames per seconds have been demonstrated.

  4. Application of Beyond Bound Decoding for High Speed Optical Communications

    DEFF Research Database (Denmark)

    Li, Bomin; Larsen, Knud J.; Vegas Olmos, Juan José;

    2013-01-01

    This paper studies the application of beyond bound decoding method for high speed optical communications. This hard-decision decoding method outperforms traditional minimum distance decoding method, with a total net coding gain of 10.36 dB.......This paper studies the application of beyond bound decoding method for high speed optical communications. This hard-decision decoding method outperforms traditional minimum distance decoding method, with a total net coding gain of 10.36 dB....

  5. High-speed optical signal processing using time lenses

    DEFF Research Database (Denmark)

    Galili, Michael; Hu, Hao; Guan, Pengyu;

    2015-01-01

    This paper will discuss time lenses and their broad range of applications. A number of recent demonstrations of complex high-speed optical signal processing using time lenses will be outlined with focus on the operating principle.......This paper will discuss time lenses and their broad range of applications. A number of recent demonstrations of complex high-speed optical signal processing using time lenses will be outlined with focus on the operating principle....

  6. A new sensitive system for measurement of thermally and optically stimulated luminescence

    DEFF Research Database (Denmark)

    Markey, B.G.; Bøtter-Jensen, L.; Poolton, N.R.J.

    1996-01-01

    An automatic system developed at RisO National Laboratory for measuring thermally and optically stimulated luminescence (TL, OSL) is widely used for radiation dose measurements. In the present model, high excitation and detection efficiencies were attempted, but inevitably there is a constant...... optics of the system with a combination of ellipsoidal mirrors and light guides, which also serve to make the system more flexible in choice of excitation source when OSL measurements are required. A variety of new light sources might be employed, adapted to allow the most efficient wavelengths...

  7. A plateau in the sensitivity of a compact optically pumped atomic magnetometer

    Directory of Open Access Journals (Sweden)

    Natsuhiko Mizutani

    2014-05-01

    Full Text Available In a compact optically pumped atomic magnetometer (OPAM, there is a plateau in the sensitivity where the dependence of the sensitivity on pumping power is small compared with that predicted by the uniform polarization model. The mechanism that generates this plateau was explained by numerical analysis. The distribution of spin polarization in the alkali metal cell of an OPAM was modeled using the Bloch equation incorporating a diffusion term and an equation for the attenuation of the pump beam. The model was well-fitted to the experimental results for a module with a cubic cell with 20 mm sides and pump and probe beams with 8 mm diameter. On the plateau, strong magnetic response was generated at the regions that were not illuminated directly by the intense pump beam, while at the same time spin polarization as large as 0.5 was maintained due to diffusion of the spin-polarized atoms. Thus, the sensitivity of the magnetometer monitored with a probe beam decreases only slightly with increasing pump beam intensity because the spin polarization under an intense pump beam is saturated. This plateau, which is characteristic of this type of magnetometer using a narrow pump and probe beams, can be used in arrays of magnetometers because it enables stable operation with little sensitivity fluctuation from changes in pump beam power.

  8. New Architecture of Optical Interconnect for High-Speed Optical Computerized Data Networks (Nonlinear Response

    Directory of Open Access Journals (Sweden)

    El-Sayed A. El-Badawy

    2008-02-01

    Full Text Available Although research into the use of optics in computers has increased in the last and current decades, the fact remains that electronics is still superior to optics in almost every way. Research into the use of optics at this stage mirrors the research into electronics after the 2nd World War. The advantages of using fiber optics over wiring are the same as the argument for using optics over electronics in computers. Even through totally optical computers are now a reality, computers that combine both electronics and optics, electro-optic hybrids, have been in use for some time. In the present paper, architecture of optical interconnect is built up on the bases of four Vertical-Cavity Surface- Emitting Laser Diodes (VCSELD and two optical links where thermal effects of both the diodes and the links are included. Nonlinear relations are correlated to investigate the power-current and the voltage-current dependences of the four devices. The good performance (high speed of the interconnect is deeply and parametrically investigated under wide ranges of the affecting parameters. The high speed performance is processed through three different effects, namely the device 3-dB bandwidth, the link dispersion characteristics, and the transmitted bit rate (soliton. Eight combinations are investigated; each possesses its own characteristics. The best architecture is the one composed of VCSELD that operates at 850 nm and the silica fiber whatever the operating set of causes. This combination possesses the largest device 3-dB bandwidth, the largest link bandwidth and the largest soliton transmitted bit rate. The increase of the ambient temperature reduces the high-speed performance of the interconnect

  9. New Architecture of Optical Interconnect for High-Speed Optical Computerized Data Networks (Nonlinear Response

    Directory of Open Access Journals (Sweden)

    El-Sayed A. El-Badawy

    2008-02-01

    Full Text Available Although research into the use of optics in computers has increased in the last and current decades, the fact remains that electronics is still superior to optics in almost every way. Research into the use of optics at this stage mirrors the research into electronics after the 2nd World War. The advantages of using fiber optics over wiring are the same as the argument for using optics over electronics in computers. Even through totally optical computers are now a reality, computers that combine both electronics and optics, electro-optic hybrids, have been in use for some time. In the present paper, architecture of optical interconnect is built up on the bases of four Vertical-Cavity Surface- Emitting Laser Diodes (VCSELD and two optical links where thermal effects of both the diodes and the links are included. Nonlinear relations are correlated to investigate the power-current and the voltage-current dependences of the four devices. The good performance (high speed of the interconnect is deeply and parametrically investigated under wide ranges of the affecting parameters. The high speed performance is processed through three different effects, namely the device 3-dB bandwidth, the link dispersion characteristics, and the transmitted bit rate (soliton. Eight combinations are investigated; each possesses its own characteristics. The best architecture is the one composed of VCSELD that operates at 850 nm and the silica fiber whatever the operating set of causes. This combination possesses the largest device 3-dB bandwidth, the largest link bandwidth and the largest soliton transmitted bit rate. The increase of the ambient temperature reduces the high-speed performance of the interconnect

  10. High-resolution optical functional mapping of the human somatosensory cortex

    Directory of Open Access Journals (Sweden)

    Stefan P Koch

    2010-06-01

    Full Text Available Non-invasive optical imaging of brain function has been promoted in a number of fields in which functional magnetic resonance imaging (fMRI is limited due to constraints induced by the scanning environment. Beyond physiological and psychological research, bedside monitoring and neurorehabilitation may be relevant clinical applications that are yet little explored. A major obstacle to advocate the tool in clinical research is insufficient spatial resolution. Based on a multi-distance high-density optical imaging setup, we here demonstrate a dramatic increase in sensitivity of the method. We show that optical imaging allows for the differentiation between activations of single finger representations in the primary somatosensory cortex (SI. Methodologically our findings confirm results in a pioneering study by Zeff et al. (2007 and extend them to the homuncular organization of SI. After performing a motor task, 8 subjects underwent vibrotactile stimulation of the little finger and the thumb. We used a high-density diffuse-optical sensing array in conjunction with optical tomographic reconstruction. Optical imaging disclosed three discrete activation foci one for motor and 2 discrete foci for vibrotactile stimulation of the 1st and 5th finger respectively. The results were co-registered to the individual anatomical brain anatomy (MRI which confirmed the localization in the expected cortical gyri in 4 subjects. This advance in spatial resolution opens new perspectives to apply optical imaging in the research on plasticity notably in patients undergoing neurorehabilitation.

  11. Recent trends in high spin sensitivity magnetic resonance

    Science.gov (United States)

    Blank, Aharon; Twig, Ygal; Ishay, Yakir

    2017-07-01

    new ideas, show how these limiting factors can be mitigated to significantly improve the sensitivity of induction detection. Finally, we outline some directions for the possible applications of high-sensitivity induction detection in the field of electron spin resonance.

  12. Photoacoustic absorption spectrometer for highly transparent dielectrics with parts-per-million sensitivity

    Science.gov (United States)

    Waasem, Niklas; Fieberg, Stephan; Hauser, Janosch; Gomes, Gregory; Haertle, Daniel; Kühnemann, Frank; Buse, Karsten

    2013-02-01

    A sensitive photoacoustic absorption spectrometer for highly transparent solids has been built and tested. As the light source an optical parametrical oscillator pumped by a nanosecond pulse laser with 10 Hz repetition rate is employed, covering the complete wavelength range from 407 to 2600 nm. A second-harmonic-generation unit extends the range of accessible wavelengths down to 212 nm. A lead-zirconate-titanate piezo transducer, directly coupled to the sample, detects the photoacoustically generated sound waves. Absorption spectra of lithium triborate, lithium niobate, and alpha barium borate crystals with absorption coefficients down to 10-5 cm-1 are presented.

  13. Human MCG measurements with a high-sensitivity potassium atomic magnetometer.

    Science.gov (United States)

    Kamada, K; Ito, Y; Kobayashi, T

    2012-06-01

    Measuring biomagnetic fields, such as magnetocardiograms (MCGs), is important for investigating biological functions. To address to this need, we developed an optically pumped atomic magnetometer. In this study, human MCGs were acquired using a potassium atomic magnetometer without any modulating systems. The sensitivity of the magnetometer is comparable to that of high-T(c) superconducting quantum interference devices (SQUIDs) and is sufficient for acquiring human MCGs. The activity of a human heart estimated from the MCG maps agrees well with that measured with SQUID magnetometers. Thus, our magnetometer produces reliable results, which demonstrate the potential of our atomic magnetometer for biomagnetic measurements.

  14. Pulsed Discharge Helium Ionization Detector for Highly Sensitive Aquametry.

    Science.gov (United States)

    Mowry, Curtis D; Pimentel, Adam S; Sparks, Elizabeth S; Moorman, Matthew W; Achyuthan, Komandoor E; Manginell, Ronald P

    2016-01-01

    Trace moisture quantitation is crucial in medical, civilian and military applications. Current aquametry technologies are limited by the sample volume, reactivity, or interferences, and/or instrument size, weight, power, cost, and complexity. We report for the first time on the use of a pulsed discharge helium ionization detector (PDHID-D2) (∼196 cm(3)) for the sensitive (limit of detection, 0.047 ng; 26 ppm), linear (r(2) >0.99), and rapid (volume of liquid or gas. The relative humidity sensitivity was 0.22% (61.4 ppmv) with a limit of detection of less than 1 ng moisture with gaseous samples. The sensitivity was 10 to 100 to fold superior to competing technologies without the disadvantages inherent to these technologies. The PDHID-D2, due to its small footprint and low power requirement, has good size, weight, and power-portability (SWAPP) factors. The relatively low cost (∼$5000) and commercial availability of the PDHID-D2 makes our technique applicable to highly sensitive aquametry.

  15. Portable evanescent wave fiber biosensor for highly sensitive detection of Shigella

    Science.gov (United States)

    Xiao, Rui; Rong, Zhen; Long, Feng; Liu, Qiqi

    2014-11-01

    A portable evanescent wave fiber biosensor was developed to achieve the rapid and highly sensitive detection of Shigella. In this study, a DNA probe was covalently immobilized onto fiber-optic biosensors that can hybridize with a fluorescently labeled complementary DNA. The sensitivity of detection for synthesized oligonucleotides can reach 10-10 M. The surface of the sensor can be regenerated with 0.5% sodium dodecyl sulfate solution (pH 1.9) for over 30 times without significant deterioration of performance. The total analysis time for a single sample, including the time for measurement and surface regeneration, was less than 6 min. We employed real-time polymerase chain reaction (PCR) and compared the results of both methods to investigate the actual Shigella DNA detection capability of the fiber-optic biosensor. The fiber-optic biosensor could detect as low as 102 colony-forming unit/mL Shigella. This finding was comparable with that by real-time PCR, which suggests that this method is a potential alternative to existing detection methods.

  16. Highly Sensitive and Miniaturized Fluorescence Detection System with an Autonomous Capillary Fluid Manipulation Chip

    Directory of Open Access Journals (Sweden)

    Ji Fang

    2012-05-01

    Full Text Available This paper presents a novel, highly sensitive and ultra-small fluorescent detection system, including an autonomous capillary fluid manipulation chip. The optical detector integrates a LED light source, all necessary optical components, and a photodiode with preamplifier into one package of about 2 cm × 2 cm × 2 cm. Also, the low-cost and simple pumpless microfluidic device works well in sample preparation and manipulation. This chip consists of capillary stop valves and trigger valves which are fabricated by lithography and then bonded with a polydimethylsiloxane-ethylene oxide polymer polydimethylsiloxane (PEO-PDMS cover. The contact angle of the PEO-PDMS can be adjusted by changing the concentration of the PEO. Hence, the fluidic chip can achieve functionalities such as timing features and basic logical functions. The prototype has been tested by fluorescence dye 5-Carboxyfluorescein (5-FAM dissolved into the solvent DMSO (Dimethyl Sulfoxide. The results prove a remarkable sensitivity at a pico-scale molar, around 1.08 pM. The low-cost and miniaturized optical detection system, with a self-control capillary-driven microfluidic chip developed in this work, can be used as the crucial parts in portable biochemical detection applications and point of care testing.

  17. Aqueye+: a new ultrafast single photon counter for optical high time resolution astrophysics

    CERN Document Server

    Zampieri, L; Barbieri, C; Verroi, E; Barbieri, M; Ceribella, G; D'Alessandro, M; Farisato, G; Di Paola, A; Zoccarato, P

    2015-01-01

    Aqueye+ is a new ultrafast optical single photon counter, based on single photon avalanche photodiodes (SPAD) and a 4-fold split-pupil concept. It is a completely revisited version of its predecessor, Aqueye, successfully mounted at the 182 cm Copernicus telescope in Asiago. Here we will present the new technological features implemented on Aqueye+, namely a state of the art timing system, a dedicated and optimized optical train, a high sensitivity and high frame rate field camera and remote control, which will give Aqueye plus much superior performances with respect to its predecessor, unparalleled by any other existing fast photometer. The instrument will host also an optical vorticity module to achieve high performance astronomical coronography and a real time acquisition of atmospheric seeing unit. The present paper describes the instrument and its first performances.

  18. Resolving molecular vibronic structure using high-sensitivity two-dimensional electronic spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Bizimana, Laurie A.; Brazard, Johanna; Carbery, William P.; Gellen, Tobias; Turner, Daniel B., E-mail: dturner@nyu.edu [Department of Chemistry, New York University, 100 Washington Square East, New York, New York 10003 (United States)

    2015-10-28

    Coherent multidimensional optical spectroscopy is an emerging technique for resolving structure and ultrafast dynamics of molecules, proteins, semiconductors, and other materials. A current challenge is the quality of kinetics that are examined as a function of waiting time. Inspired by noise-suppression methods of transient absorption, here we incorporate shot-by-shot acquisitions and balanced detection into coherent multidimensional optical spectroscopy. We demonstrate that implementing noise-suppression methods in two-dimensional electronic spectroscopy not only improves the quality of features in individual spectra but also increases the sensitivity to ultrafast time-dependent changes in the spectral features. Measurements on cresyl violet perchlorate are consistent with the vibronic pattern predicted by theoretical models of a highly displaced harmonic oscillator. The noise-suppression methods should benefit research into coherent electronic dynamics, and they can be adapted to multidimensional spectroscopies across the infrared and ultraviolet frequency ranges.

  19. Case studies of high-sensitivity monitoring of natural and engineered slopes

    Directory of Open Access Journals (Sweden)

    Werner Lienhart

    2015-08-01

    Full Text Available High-sensitivity monitoring solutions are crucial for early warning systems of earth structures. In this paper, we discuss the design and implementation of such systems for natural and engineered slopes using two case studies. At the Gradenbach Observatory, one key element of the monitoring system is a large fiber optic strain rosette embedded in the slope. We demonstrate that the strain rosette can depict landslide deformations much earlier than geodetic sensors like GPS or total stations and is therefore well suitable for an early warning system. In a second application we report the construction of a reinforced earth structure using geogrids. A distributed fiber optic measurement system was installed to measure the current operating grade of the geogrids within the earth structure. About 2 km of Brillouin sensing cables were installed in the project area. It is demonstrated that the developed monitoring system is well suited for assessing the current state of health of reinforced earth structures.

  20. High Sensitivity Terahertz Detection through Large-Area Plasmonic Nano-Antenna Arrays

    Science.gov (United States)

    Yardimci, Nezih Tolga; Jarrahi, Mona

    2017-01-01

    Plasmonic photoconductive antennas have great promise for increasing responsivity and detection sensitivity of conventional photoconductive detectors in time-domain terahertz imaging and spectroscopy systems. However, operation bandwidth of previously demonstrated plasmonic photoconductive antennas has been limited by bandwidth constraints of their antennas and photoconductor parasitics. Here, we present a powerful technique for realizing broadband terahertz detectors through large-area plasmonic photoconductive nano-antenna arrays. A key novelty that makes the presented terahertz detector superior to the state-of-the art is a specific large-area device geometry that offers a strong interaction between the incident terahertz beam and optical pump at the nanoscale, while maintaining a broad operation bandwidth. The large device active area allows robust operation against optical and terahertz beam misalignments. We demonstrate broadband terahertz detection with signal-to-noise ratio levels as high as 107 dB. PMID:28205615

  1. Case studies of high-sensitivity monitoring of natural and engineered slopes

    Institute of Scientific and Technical Information of China (English)

    Werner Lienhart

    2015-01-01

    High-sensitivity monitoring solutions are crucial for early warning systems of earth structures. In this paper, we discuss the design and implementation of such systems for natural and engineered slopes using two case studies. At the Gradenbach Observatory, one key element of the monitoring system is a large fiber optic strain rosette embedded in the slope. We demonstrate that the strain rosette can depict landslide deformations much earlier than geodetic sensors like GPS or total stations and is therefore well suitable for an early warning system. In a second application we report the construction of a reinforced earth structure using geogrids. A distributed fiber optic measurement system was installed to measure the current operating grade of the geogrids within the earth structure. About 2 km of Brillouin sensing cables were installed in the project area. It is demonstrated that the developed monitoring system is well suited for assessing the current state of health of reinforced earth structures.

  2. High Sensitivity Terahertz Detection through Large-Area Plasmonic Nano-Antenna Arrays

    Science.gov (United States)

    Yardimci, Nezih Tolga; Jarrahi, Mona

    2017-02-01

    Plasmonic photoconductive antennas have great promise for increasing responsivity and detection sensitivity of conventional photoconductive detectors in time-domain terahertz imaging and spectroscopy systems. However, operation bandwidth of previously demonstrated plasmonic photoconductive antennas has been limited by bandwidth constraints of their antennas and photoconductor parasitics. Here, we present a powerful technique for realizing broadband terahertz detectors through large-area plasmonic photoconductive nano-antenna arrays. A key novelty that makes the presented terahertz detector superior to the state-of-the art is a specific large-area device geometry that offers a strong interaction between the incident terahertz beam and optical pump at the nanoscale, while maintaining a broad operation bandwidth. The large device active area allows robust operation against optical and terahertz beam misalignments. We demonstrate broadband terahertz detection with signal-to-noise ratio levels as high as 107 dB.

  3. Malaria pigment crystals as magnetic micro-rotors: key for high-sensitivity diagnosis

    CERN Document Server

    Butykai, A; Kocsis, V; Szaller, D; Bordacs, S; Tatrai-Szekeres, E; Kiss, L F; Bota, A; Vertessy, B G; Zelles, T; Kezsmarki, I

    2012-01-01

    The need to develop new methods for the high-sensitivity diagnosis of malaria has initiated a global activity in medical and interdisciplinary sciences. Most of the diverse variety of emerging techniques are based on research-grade instruments, sophisticated reagent-based assays or rely on expertise. Here, we suggest an alternative optical methodology with an easy-to-use and cost-effective instrumentation, which takes advantage of the unique properties of malaria pigment revealed in the present study. Malaria pigment, also called hemozoin, is an insoluble microcrystalline form of heme. We found that these crystallites show remarkable magnetic and optical anisotropy distinctly from any other components of blood. In suspensions they can simultaneously act as magnetically driven micro-rotors and spinning polarizers. These properties can gain fundamental importance not only in the diagnosis of malaria and in therapies, where hemozoin is considered as drug target or immune modulator, but generally in the magnetic ...

  4. Development of a highly sensitive galvanic cell oxygen sensor.

    Science.gov (United States)

    Ogino, H; Asakura, K

    1995-02-01

    A highly sensitive galvanic cell oxygen sensor was successfully developed for determining parts per billion of oxygen in high purity gases such as nitrogen, argon, etc. The response of this improved sensor was proportional in the range of oxygen concentrations from 10.0 ppm to the detection limit. The response speed in this study was improved to within 90 sec for a 90% response. The detection limit was tentatively found to be less than 0.4 ppb corresponding to S N = 2 .

  5. Influence of load by high power on the optical coupler

    Science.gov (United States)

    Bednarek, Lukas; Poboril, Radek; Vanderka, Ales; Hajek, Lukas; Nedoma, Jan; Vasinek, Vladimir

    2016-12-01

    Nowadays, aging of the optical components is a very current topic. Therefore, some investigations are focused on this area, so that the aging of the optical components is accelerated by thermal, high power and gamma load. This paper deals by findings of the influence of the load by laser with high optical power on the transmission parameters of the optical coupler. The investigated coupler has one input and eight outputs (1x8). Load by laser with high optical power is realized using a fiber laser with a cascade configuration EDFA amplifiers. The output power of the amplifier is approximately 250 mW. Duration of the load is moving from 104 hours to 139 hours. After each load, input power and output powers of all branches are measured. Following parameters of the optical coupler are calculated using formulas: the insertion losses of the individual branches, split ratio, total losses, homogeneity of the losses and cross-talk between different branches. All measurements are performed at wavelengths 1310 nm and 1550 nm. Individual optical powers are measured 20 times, due to the exclusion of statistical error of the measurement. After measuring, the coupler is connected to the amplifier for next cycle of the load. The paper contains an evaluation of the results of the coupler before and after four cycles of the burden.

  6. Ultra-high-speed Optical Signal Processing using Silicon Photonics

    DEFF Research Database (Denmark)

    Oxenløwe, Leif Katsuo; Ji, Hua; Jensen, Asger Sellerup

    on silicon photonics. In particular we use nano-engineered silicon waveguides (nanowires) [1] enabling efficient phasematched four-wave mixing (FWM), cross-phase modulation (XPM) or self-phase modulation (SPM) for ultra-high-speed optical signal processing of ultra-high bit rate serial data signals. We show......— In supercomputers, the optical inter-connects are getting closer and closer to the processing cores. Today, a single supercomputer system has as many optical links as the whole worldwide web together, and it is envisaged that future computing chips will contain multiple electronic processor cores...... with a photonic layer on top to interconnect them. For such systems, silicon is an attractive candidate enabling both electronic and photonic control. For some network scenarios, it may be beneficial to use optical on-chip packet switching, and for high data-density environments one may take advantage...

  7. Development of high $\\beta^*$-optics for ALICE

    CERN Document Server

    Hermes, Pascal Dominik; Wessels, Johannes Peter

    This thesis describes a feasibility study for a special optical configuration in Insertion Region 2 (IR2) of the Large Hadron Collider (LHC), which is host of the ALICE detector. This configuration allows the study of elastic and diffractive scattering during LHC high-intensity proton operation, in parallel to the nominal physics studies in all LHC experiments at the design energy of 7 TeV per beam. Such measurements require the instal- lation of additional Roman Pot (RP) detectors in the very forward region, at longitudinal distances of 150 m to 220 m from the Interaction Point (IP). Apart from being adjusted for a specific betatron phase advance between the IP and the RP detectors, such a configuration must be optimized for the largest possible $\\beta^*$ -value, to be sensitive for the smallest possible four-momentum transfer $|t|$. A value of $\\beta^*$ = 18 m is compatible with a bunch spacing of 25 ns, considering the LHC design emittance of N = 3.75 μm rad, and a required bunch-bunch separation of $12 \\...

  8. All-optical high performance graphene-photonic crystal switch

    Science.gov (United States)

    Hoseini, Mehrdad; Malekmohammad, Mohammad

    2017-01-01

    The all-optical switch is realized based on nonlinear transmission changes in Fano resonance of 2D photonic crystals (PhC) which enhances the light intensity on the graphene in PhC; and in this study, the graphene layer is used as the nonlinear material. The refractive index change of graphene layer leads to a shift in the Fano resonance frequency due to the input light intensity through the Kerr nonlinear effect. Through finite-difference time-domain simulation, it is found that the high performance of all-optical switching can be achieved by the designed structure with a threshold pump intensity as low as MW/cm2. This structure is featured by optical bistability. The obtained results are applicable in micro optical integrated circuits for modulators, switches and logic elements for optical computation.

  9. Ultra-high Frequency Linear Fiber Optic Systems

    CERN Document Server

    Lau, Kam

    2011-01-01

    This book provides an in-depth treatment of both linear fiber-optic systems and their key enabling devices. It presents a concise but rigorous treatment of the theory and practice of analog (linear) fiber-optics links and systems that constitute the foundation of Hybrid Fiber Coax infrastructure in present-day CATV distribution and cable modem Internet access. Emerging applications in remote fiber-optic feed for free-space millimeter wave enterprise campus networks are also described. Issues such as dispersion and interferometric noise are treated quantitatively, and means for mitigating them are explained. This broad but concise text will thus be invaluable not only to students of fiber-optics communication but also to practicing engineers. To the second edition of this book important new aspects of linear fiber-optic transmission technologies are added, such as high level system architectural issues, algorithms for deriving the optimal frequency assignment, directly modulated or externally modulated laser t...

  10. Performance of terahertz metamaterials as high-sensitivity sensor

    Science.gov (United States)

    He, Yanan; Zhang, Bo; Shen, Jingling

    2017-09-01

    A high-sensitivity sensor based on the resonant transmission characteristics of terahertz (THz) metamaterials was investigated, with the proposal and fabrication of rectangular bar arrays of THz metamaterials exhibiting a period of 180 μm on a 25 μm thick flexible polyimide. Varying the size of the metamaterial structure revealed that the length of the rectangular unit modulated the resonant frequency, which was verified by both experiment and simulation. The sensing characteristics upon varying the surrounding media in the sample were tested by simulation and experiment. Changing the surrounding medium from that of air to that of alcohol or oil produced resonant frequency redshifts of 80 GHz or 150 GHz, respectively, which indicates that the sensor possessed a high sensitivity of 667 GHz per unit of refractive index. Finally, the influence of the sample substrate thickness on the sensor sensitivity was investigated by simulation. It may be a reference for future sensor design.

  11. High-sensitivity strain visualization using electroluminescence technologies

    Science.gov (United States)

    Xu, Jian; Jo, Hongki

    2016-04-01

    Visualizing mechanical strain/stress changes is an emerging area in structural health monitoring. Several ways are available for strain change visualization through the color/brightness change of the materials subjected to the mechanical stresses, for example, using mechanoluminescence (ML) materials and mechanoresponsive polymers (MRP). However, these approaches were not effectively applicable for civil engineering system yet, due to insufficient sensitivity to low-level strain of typical civil structures and limitation in measuring both static and dynamic strain. In this study, design and validation for high-sensitivity strain visualization using electroluminescence technologies are presented. A high-sensitivity Wheatstone bridge, of which bridge balance is precisely controllable circuits, is used with a gain-adjustable amplifier. The monochrome electroluminescence (EL) technology is employed to convert both static and dynamic strain change into brightness/color change of the EL materials, through either brightness change mode (BCM) or color alternation mode (CAM). A prototype has been made and calibrated in lab, the linearity between strain and brightness change has been investigated.

  12. HIGHLY SENSITIVE CATALASE ELECTRODE BASED ON POLYPYRROLE FILMS WITH MICROCONTAINERS

    Institute of Scientific and Technical Information of China (English)

    Yu-ying Gao; Gao-quan Shi

    2006-01-01

    Highly sensitive catalase electrodes for sensing hydrogen peroxide have been fabricated based on polypyrrole films with microcontainers. The microcontainers have a cup-like morphology and are arranged in a density of 4000 units cm-2.Catalase was immobilized into the polypyrrole films with microcontainers (Ppy-mc), which were coated on a Pt substrate electrode. The catalase/Ppy-mc/Pt electrode showed linear response to hydrogen peroxide in the range of 0-18 mmol/L at a potential of -0.3 V (versus SCE). Its sensitivity was measured to be approximately 3.64 μA (mmol/L)-1 cm-2, which is about two times that of the electrode fabricated from a flat Ppy film (catalase/Ppy-flat/Pt electrode). The electrode is highly selective for hydrogen peroxide and its sensitivity is interfered by potential interferents such as ascorbic acid, urea and fructose. Furthermore, such catalase electrodes showed long-term storage stability of 15 days under dry conditions at 4℃.

  13. Optical Tomography of MMP Activity Allows a Sensitive Noninvasive Characterization of the Invasiveness and Angiogenesis of SCC Xenografts

    Directory of Open Access Journals (Sweden)

    Wa'el Al Rawashdeh

    2014-03-01

    Full Text Available For improved tumor staging and therapy control, imaging biomarkers are of great interest allowing a noninvasive characterization of invasiveness. In squamous epithelial skin and cervix lesions, transition to invasive stages is associated with enhanced matrix metalloproteinase (MMP activity, increased angiogenesis, and worsened prognosis. Thus, we investigated MMP activity as imaging biomarker of invasiveness and the potential of optical tomography in characterizing the angiogenic and invasive behavior of skin squamous cell carcinoma (SCC xenografts. MMP activity was measured in vivo in HaCaT-ras A-5RT3 tumors at different angiogenic and invasive stages (onset of angiogenesis, intermediate and highly angiogenic, invasive stage and after 1 week of sunitinib treatment by fluorescence molecular tomography–microcomputed tomography imaging using an activatable probe. Treatment response was additionally assessed morphologically by optical coherence tomography (OCT. In vivo MMP activity significantly differed between the groups, revealing highest levels in the highly angiogenic, invasive tumors that were confirmed by immunohistochemistry. At the onset of angiogenesis with lowest MMP activity, fibroblasts were detected in the MMP-positive areas, whereas macrophages were absent. Accumulation of both cell types occurred in both invasive groups, again to a significantly higher degree at the most invasive and angiogenic stage. Sunitinib treatment significantly reduced the MMP activity and accumulation of fibroblasts and macrophages and blocked tumor invasion that was additionally visualized by OCT. Human cervical SCCs also showed high MMP activity and a similar stromal composition as the HaCaT xenografts, whereas normal tissue was negative. This study strongly suggests MMP activity as imaging biomarker and demonstrates the high sensitivity of optical tomography in determining tumor invasiveness that can morphologically be supported by OCT.

  14. In-line microfluidic integration of photonic crystal fibres as a highly sensitive refractometer.

    Science.gov (United States)

    Wu, Chuang; Tse, Ming-Leung Vincent; Liu, Zhengyong; Guan, Bai-Ou; Zhang, A Ping; Lu, Chao; Tam, Hwa-Yaw

    2014-11-07

    Photonic crystal fibres appear to be an ideal platform for the realisation of novel optofluidic devices and sensors due to their waveguide nature and microstructured architecture. In this paper, we present the fabrication and characterisation of an in-line photonic crystal fibre microfluidic refractometer enabled by a C-shaped fibre. The C-shaped fibre spliced in-between the photonic crystal fibre and the single-mode fibre allows simultaneous in-line optical signal delivery and analyte fluid feeding. Through an arc discharge pre-treatment technique, we successfully achieve selective exploitation of only the central two channels of the photonic crystal fibre for microfluidic sensing. After constructing a Sagnac interferometer, a highly sensitive refractometer with a sensitivity of 8699 nm per RIU was achieved experimentally; this agrees very well with the theoretical value of 8675 nm per RIU. As a demonstration for label-free optical sensing application, the refractometer was used to measure the concentration of NaCl solution with a sensitivity of 15.08 nm/(1 wt%) and a detection limit of 2.3 × 10(-3) wt% (23 ppm).

  15. The AOLI low-order non-linear curvature wavefront sensor: a method for high sensitivity wavefront reconstruction

    CERN Document Server

    Crass, Jonathan; Femenia, Bruno; King, David L; Mackay, Craig D; Rebolo-López, Rafael; Labadie, Lucas; Garrido, Antonio Pérez; Balcells, Marc; Sánchez, Anastasio Díaz; Fuensalida, Jesús Jimenez; Lopez, Roberto L; Oscoz, Alejandro; Prieto, Jorge A Pérez; Rodríguez-Ramos, Luis F; Villó, Isidro

    2012-01-01

    The Adaptive Optics Lucky Imager (AOLI) is a new instrument under development to demonstrate near diffraction limited imaging in the visible on large ground-based telescopes. We present the adaptive optics system being designed for the instrument comprising a large stroke deformable mirror, fixed component non-linear curvature wavefront sensor and photon-counting EMCCD detectors. We describe the optical design of the wavefront sensor where two photoncounting CCDs provide a total of four reference images. Simulations of the optical characteristics of the system are discussed, with their relevance to low and high order AO systems. The development and optimisation of high-speed wavefront reconstruction algorithms are presented. Finally we discuss the results of simulations to demonstrate the sensitivity of the system.

  16. Development of highly sensitive monolithic interferometer for infrared planet search

    Directory of Open Access Journals (Sweden)

    Jiang P.

    2011-07-01

    Full Text Available We present the design, fabrication and testing of a highly sensitive monolithic interferometer for InfraRed Exoplanet Tracker (IR-ET. This interferometer is field-compensated, thermal-stable for working in the wavelength range between 0.8 and 1.35 μm. Two arms of the interferometer creates a fixed delay of 18.0 mm, which is optimized to have the best sensitivity for radial velocity measurements of slow-rotating M dwarfs for planet detection. IR-ET is aiming to reach 3–20 m/s Doppler precision for J<10 M dwarfs in less than 15 min exposures. We plan to conduct a planet survey around hundreds of nearby M dwarfs through collaborations with Astrophysical Research Consortium scientists in 2011–2014.

  17. Polymer-Particle Pressure-Sensitive Paint with High Photostability

    Directory of Open Access Journals (Sweden)

    Yu Matsuda

    2016-04-01

    Full Text Available We propose a novel fast-responding and paintable pressure-sensitive paint (PSP based on polymer particles, i.e. polymer-particle (pp-PSP. As a fast-responding PSP, polymer-ceramic (PC-PSP is widely studied. Since PC-PSP generally consists of titanium (IV oxide (TiO2 particles, a large reduction in the luminescent intensity will occur due to the photocatalytic action of TiO2. We propose the usage of polymer particles instead of TiO2 particles to prevent the reduction in the luminescent intensity. Here, we fabricate pp-PSP based on the polystyrene particle with a diameter of 1 μm, and investigate the pressure- and temperature-sensitives, the response time, and the photostability. The performances of pp-PSP are compared with those of PC-PSP, indicating the high photostability with the other characteristics comparable to PC-PSP.

  18. New application of superconductors: high sensitivity cryogenic light detectors

    CERN Document Server

    Cardani, L; Casali, N; Casellano, M G; Colantoni, I; Coppolecchia, A; Cosmelli, C; Cruciani, A; D'Addabbo, A; Di Domizio, S; Martinez, M; Tomei, C; Vignati, M

    2016-01-01

    In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superconductor can break the Cooper pairs, causing sizable variations in the kinetic inductance and, thus, in the response of the LC circuit. The continuous monitoring of the amplitude and frequency modulation allows to reconstruct the incident energy with excellent sensitivity. This concept is at the basis of Kinetic Inductance Detectors (KIDs), that are characterized by natural aptitude to multiplexed read-out (several sensors can be tuned to different resonant frequencies and coupled to the same line), resolution of few eV, stable behavior over a wide temperature range, and ease in fabrication. We present the results ob...

  19. Apparatus and Methods Using Highly Optically Dispersive Media

    Science.gov (United States)

    2011-08-02

    of two-beam interferometers , such as, e.g., a Michelson interferometer , a Twyman-Green interferometer , and others known in the art. An alternative...guiding fiber . 20 32. The apparatus of claim 1, wherein the apparatus is a spectroscopic interferometer . 33. The apparatus of claim 1, wherein the...Zhimin et a!. "Enhancing the spectral sensitivity of interferometers using slow-light media". Optics Letters, vol. 32, No. 8, Apr. 15, 2007, pp. 915

  20. Highly sensitive detection of urinary cadmium to assess personal exposure

    Energy Technology Data Exchange (ETDEWEB)

    Argun, Avni A.; Banks, Ashley M.; Merlen, Gwendolynne; Tempelman, Linda A. [Giner, Inc., 89 Rumford Ave., Newton 02466, MA United States (United States); Becker, Michael F.; Schuelke, Thomas [Fraunhofer USA – CCL, 1449 Engineering Research Ct., East Lansing 48824, MI (United States); Dweik, Badawi M., E-mail: bdweik@ginerinc.com [Giner, Inc., 89 Rumford Ave., Newton 02466, MA United States (United States)

    2013-04-22

    Highlights: ► An electrochemical sensor capable of detecting cadmium at parts-per-billion levels in urine. ► A novel fabrication method for Boron-Doped Diamond (BDD) ultramicroelectrode (UME) arrays. ► Unique combination of BDD UME arrays and a differential pulse voltammetry algorithm. ► High sensitivity, high reproducibility, and very low noise levels. ► Opportunity for portable operation to assess on-site personal exposure. -- Abstract: A series of Boron-Doped Diamond (BDD) ultramicroelectrode arrays were fabricated and investigated for their performance as electrochemical sensors to detect trace level metals such as cadmium. The steady-state diffusion behavior of these sensors was validated using cyclic voltammetry followed by electrochemical detection of cadmium in water and in human urine to demonstrate high sensitivity (>200 μA ppb{sup −1} cm{sup −2}) and low background current (<4 nA). When an array of ultramicroelectrodes was positioned with optimal spacing, these BDD sensors showed a sigmoidal diffusion behavior. They also demonstrated high accuracy with linear dose dependence for quantification of cadmium in a certified reference river water sample from the U.S. National Institute of Standards and Technology (NIST) as well as in a human urine sample spiked with 0.25–1 ppb cadmium.

  1. [Highly sensitive detection technology for biological toxins applying sugar epitopes].

    Science.gov (United States)

    Uzawa, Hirotaka

    2009-01-01

    The Shiga toxin is a highly poisonous protein produced by enterohemorrhagic Escherichia coli O157. This bacterial toxin causes the hemolytic uremic syndrome. Another plant toxin from castor beans, ricin, is also highly toxic. The toxin was used for assassination in London. Recently, there were several cases of postal matter containing ricin. Both toxins are categorized as biological warfare agents by the Centers of Disease Control and Prevention. Conventional detection methods based on the antigen-antibody reaction, PCR and other cell-free assays have been proposed. However, those approaches have drawbacks in terms of sensitivity, analytical time, or stability of the detection reagents. Therefore, development of a facile and sensitive detection method is essential. Here we describe new detection methods applying carbohydrate epitopes as the toxin ligands, which is based on the fact that the toxins bind cell-surface oligosaccharides. Namely, the Shiga toxin has an affinity for globobiosyl (Gb(2)) disaccharide, and ricin binds the beta-D-galactose residue. For Shiga toxin detection, surface plasmon resonance (SPR) was applied. A polyanionic Gb(2)-glycopolymer was designed for this purpose, and it was used for the assembly of Gb(2)-chips using alternating layer-by-layer technology. The method allowed us to detect the toxin at a low concentration of LD(50). A synthetic carbohydrate ligand for ricin was designed and immobilized on the chips. SPR analysis with the chips allows us to detect ricin in a highly sensitive and facile manner (10 pg/ml, 5 min). Our present approaches provide a highly effective way to counter bioterrorism.

  2. Recent progress on high-speed optical transmission

    Directory of Open Access Journals (Sweden)

    Jianjun Yu

    2016-05-01

    Full Text Available The recently reported high spectral efficiency (SE and high-baud-rate signal transmission are all based on digital coherent optical communications and digital signal processing (DSP. DSP simplifies the reception of advanced modulation formats and also enables the major electrical and optical impairments to be processed and compensated in the digital domain, at the transmitter or receiver side. In this paper, we summarize the research progress on high-speed signal generation and detection and also show the progress on DSP for high-speed signal detection. We also report the latest progress on multi-core and multi-mode multiplexing.

  3. High-sensitivity observations of solar flare decimeter radiation

    Science.gov (United States)

    Benz, A. O.; Messmer, P.; Monstein, C.

    2001-01-01

    A new acousto-optic radio spectrometer has observed the 1-2 GHz radio emission of solar flares with unprecedented sensitivity. The number of detected decimeter type III bursts is greatly enhanced compared to observations by conventional spectrometers observing only one frequency at the time. The observations indicate a large number of electron beams propagating in dense plasmas. For the first time, we report weak, reversed drifting type III bursts at frequencies above simultaneous narrowband decimeter spikes. The type III bursts are reliable signatures of electron beams propagating downward in the corona, apparently away from the source of the spikes. The observations contradict the most popular spike model that places the spike sources at the footpoints of loops. Conspicuous also was an apparent bidirectional type U burst forming a fish-like pattern. It occurs simultaneously with an intense U-burst at 600-370 MHz observed in Tremsdorf. We suggest that it intermodulated with strong terrestrial interference(cellular phones) causing a spurious symmetric pattern in the spectrogram at 1.4 GHz. Symmetric features in the 1-2 GHz range, some already reported in the literature, therefore must be considered with utmost caution.

  4. Fiber optic temperature sensing with enhanced sensitivity based on spectral interferometry

    Science.gov (United States)

    Militky, J.; Kadulova, M.; Ciprian, D.; Hlubina, P.

    2017-01-01

    Temperature sensing with enhanced sensitivity based on the spectral interference of polarization modes in a highly birefringent (HB) fiber is proposed and demonstrated. A temperature sensor employs a tandem configuration of a birefringent quartz crystal and HB fiber placed between an analyzer and a polarizer. In the setup a modified channeled spectrum is generated, which shifts with the temperature change of the sensing part of the HB fiber. We analyze the measurement method theoretically and show that the sensitivity of the temperature sensing based on the wavelength interrogation is enhanced in comparison to a standard method with a fiber interferometer. We also demonstrate the enhancement of the temperature sensitivity for three HB fibers under test. Experimental results show that the temperature sensing can reach a sensitivity of -0.30 nm/K, which is enhanced in comparison to -0.10 nm/K reached for a standard measurement.

  5. High-throughput proteomics : optical approaches.

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, George S.

    2008-09-01

    Realistic cell models could greatly accelerate our ability to engineer biochemical pathways and the production of valuable organic products, which would be of great use in the development of biofuels, pharmaceuticals, and the crops for the next green revolution. However, this level of engineering will require a great deal more knowledge about the mechanisms of life than is currently available. In particular, we need to understand the interactome (which proteins interact) as it is situated in the three dimensional geometry of the cell (i.e., a situated interactome), and the regulation/dynamics of these interactions. Methods for optical proteomics have become available that allow the monitoring and even disruption/control of interacting proteins in living cells. Here, a range of these methods is reviewed with respect to their role in elucidating the interactome and the relevant spatial localizations. Development of these technologies and their integration into the core competencies of research organizations can position whole institutions and teams of researchers to lead in both the fundamental science and the engineering applications of cellular biology. That leadership could be particularly important with respect to problems of national urgency centered around security, biofuels, and healthcare.

  6. Exploring the origin of high optical absorption in conjugated polymers

    KAUST Repository

    Vezie, Michelle S.

    2016-05-16

    The specific optical absorption of an organic semiconductor is critical to the performance of organic optoelectronic devices. For example, higher light-harvesting efficiency can lead to higher photocurrent in solar cells that are limited by sub-optimal electrical transport. Here, we compare over 40 conjugated polymers, and find that many different chemical structures share an apparent maximum in their extinction coefficients. However, a diketopyrrolopyrrole-thienothiophene copolymer shows remarkably high optical absorption at relatively low photon energies. By investigating its backbone structure and conformation with measurements and quantum chemical calculations, we find that the high optical absorption can be explained by the high persistence length of the polymer. Accordingly, we demonstrate high absorption in other polymers with high theoretical persistence length. Visible light harvesting may be enhanced in other conjugated polymers through judicious design of the structure.

  7. Magneto-Optical Activity in High Index Dielectric Nanoantennas

    CERN Document Server

    de Sousa, N; Sáenz, J J; García-Martín, A

    2016-01-01

    The magneto-optical activity, namely the polarization conversion capabilities of high-index, non-absorbing, core-shell dielectric nanospheres is theoretically analyzed. We show that, in analogy with their plasmonic counterparts, the polarization conversion in resonant dielectric particles is linked to the amount of electromagnetic field probing the magneto-optical material in the system. However, in strong contrast with plasmon nanoparticles, due to the peculiar distribution of the internal fields in resonant dielectric spheres, the magneto-optical response is fully governed by the magnetic (dipolar and quadrupolar) resonances with little effect of the electric ones.

  8. Optical levitation of high purity nanodiamonds in vacuum without heating

    CERN Document Server

    Frangeskou, A C; Gines, L; Mandal, S; Williams, O A; Barker, P F; Morley, G W

    2016-01-01

    Levitated nanodiamonds containing nitrogen vacancy centres in high vacuum are a potential test bed for numerous phenomena in fundamental physics. However, experiments so far have been limited to low vacuum due to heating arising from optical absorption of the trapping laser. We show that milling pure diamond creates nanodiamonds that do not heat up as the optical intensity is raised above 700 GW/m$^2$ below 5 mbar of pressure. This advance now means that the level of attainable vacuum for nanodiamonds in optical dipole traps is no longer temperature limited.

  9. Research of high speed optical switch based on compound semiconductor

    Institute of Scientific and Technical Information of China (English)

    WANG MingHua; QI Wei; YU Hui; JIANG XiaoQing; YANG JianYi

    2009-01-01

    High-speed optical switch and its array are the crucial components of all-optical switching system. This paper presents the analytical model of a total-internal-reflection (TIR) optical switch. By employing the carrier injection effect in GaAs and the GaAs/AlGaAs double heterojunction structure, the X-junction TIR switch and the Mach-Zehnder interference (MZI) switch are demonstrated at 1.55 IJm. The measured results show that the extinction ratio of both switches exceeds 20 dB. The switching speed reaches the scale of 10 ns.

  10. High-speed image matching with coaxial holographic optical correlator

    Science.gov (United States)

    Ikeda, Kanami; Watanabe, Eriko

    2016-09-01

    A computation speed of more than 100 Gbps is experimentally demonstrated using our developed ultrahigh-speed optical correlator. To verify this high computation speed practically, the computation speeds of our optical correlator and conventional digital image matching are quantitatively compared. We use a population count function that achieves the fastest calculation speed when calculating binary matching by a central processing unit (CPU). The calculation speed of the optical correlator is dramatically faster than that using a CPU (2.40 GHz × 4) and 16 GB of random access memory, especially when the calculation data are large-scale.

  11. Highly Sensitive and Selective Sensor Chips with Graphene-Oxide Linking Layer.

    Science.gov (United States)

    Stebunov, Yury V; Aftenieva, Olga A; Arsenin, Aleksey V; Volkov, Valentyn S

    2015-10-07

    The development of sensing interfaces can significantly improve the performance of biological sensors. Graphene oxide provides a remarkable immobilization platform for surface plasmon resonance (SPR) biosensors due to its excellent optical and biochemical properties. Here, we describe a novel sensor chip for SPR biosensors based on graphene-oxide linking layers. The biosensing assay model was based on a graphene oxide film containing streptavidin. The proposed sensor chip has three times higher sensitivity than the carboxymethylated dextran surface of a commercial sensor chip. Moreover, the demonstrated sensor chips are bioselective with more than 25 times reduced binding for nonspecific interaction and can be used multiple times. We consider the results presented here of importance for any future applications of highly sensitive SPR biosensing.

  12. Soliton-based ultra-high speed optical communications

    Indian Academy of Sciences (India)

    Akira Hasegawa

    2001-11-01

    Multi-terabit/s, ultra-high speed optical transmissions over several thousands kilometers on fibers are becoming a reality. Most use RZ (Return to Zero) format in dispersion-managed fibers. This format is the only stable waveform in the presence of fiber Kerr nonlinearity and dispersion in all optical transmission lines with loss compensated by periodic amplifications. The nonlinear Schrödinger equation assisted by the split step numerical solutions is commonly used as the master equation to describe the information transfer in optical fibers. All these facts are the outcome of research on optical solitons in fibers in spite of the fact that the commonly used RZ format is not always called a soliton format. The overview presented here attempts to incorporate the role of soliton-based communications research in present day ultra-high speed communications.

  13. High-Order Modulation for Optical Fiber Transmission

    CERN Document Server

    Seimetz, Matthias

    2009-01-01

    Catering to the current interest in increasing the spectral efficiency of optical fiber networks by the deployment of high-order modulation formats, this monograph describes transmitters, receivers and performance of optical systems with high-order phase and quadrature amplitude modulation. In the first part of the book, the author discusses various transmitter implementation options as well as several receiver concepts based on direct and coherent detection, including designs of new structures. Hereby, both optical and electrical parts are considered, allowing the assessment of practicability and complexity. In the second part, a detailed characterization of optical fiber transmission systems is presented, regarding a wide range of modulation formats. It provides insight in the fundamental behavior of different formats with respect to relevant performance degradation effects and identifies the major trends in system performance.

  14. Synthesis of high purity metal oxide nanoparticles for optical applications

    Science.gov (United States)

    Baker, C.; Kim, W.; Friebele, E. J.; Villalobos, G.; Frantz, J.; Shaw, L. B.; Sadowski, B.; Fontana, J.; Dubinskii, M.; Zhang, J.; Sanghera, J.

    2014-09-01

    In this paper we present our recent research results in synthesizing various metal oxide nanoparticles for use as laser gain media (solid state as well as fiber lasers) and transparent ceramic windows via two separate techniques, co-precipitation and flame spray pyrolysis. The nanoparticles were pressed into ceramic discs that exhibited optical transmission approaching the theoretical limit and showed very high optical-to-optical lasing slope efficiency. We have also synthesized sesquioxide nanoparticles using a Flame Spray Pyrolysis (FSP) technique that leads to the synthesis of a metastable phase of sesquioxide which allows fabricating excellent optical quality transparent windows with very fine grain sizes. Finally, we present our research in the synthesis of rare earth doped boehmite nanoparticles where the rareearth ion is encased in a cage of aluminum and oxygen to prevent ion-ion proximity and energy transfer. The preforms have been drawn into fibers exhibiting long lifetimes and high laser efficiencies.

  15. High sensitive detection of high-order partial wave scattering in photoassociation of ultralcold atoms

    Institute of Scientific and Technical Information of China (English)

    Li Yu-Qing; Ma Jie; Wu Ji-Zhou; Zhang Yi-Chi; Zhao Yan-Ting; Wang Li-Rong; Xiao Lian-Tuan; Jia Suo-Tang

    2012-01-01

    We report on the observation of enhanced high-order partial wave scattering from atom-atom interaction via changing the temperature of a magneto-optical trap in the process of photoassociation. The high-order scattering partial wave is directly manifested through the large signal amplitude of the rovibrational resonance levels of trap-loss spectroscopy from photoassociation.

  16. High speed nonlinear optical components for next-generation optical communications

    OpenAIRE

    Cleary, Ciaran Sean

    2013-01-01

    Electronic signal processing systems currently employed at core internet routers require huge amounts of power to operate and they may be unable to continue to satisfy consumer demand for more bandwidth without an inordinate increase in cost, size and/or energy consumption. Optical signal processing techniques may be deployed in next-generation optical networks for simple tasks such as wavelength conversion, demultiplexing and format conversion at high speed (≥100Gb.s-1) to alleviate the pres...

  17. Influence of Smoking on Ultra-High-Frequency Auditory Sensitivity.

    Science.gov (United States)

    Prabhu, Prashanth; Varma, Gowtham; Dutta, Kristi Kaveri; Kumar, Prajwal; Goyal, Swati

    2017-04-01

    In this study, an attempt was made to determine the effect of smoking on ultra-high-frequency auditory sensitivity. The study also attempted to determine the relationship between the nature of smoking and ultra-high-frequency otoacoustic emissions (OAEs) and thresholds. The study sample included 25 smokers and 25 non-smokers. A detailed history regarding their smoking habits was collected. High-frequency audiometric thresholds and amplitudes of high-frequency distortion-product OAEs were analyzed for both ears from all participants. The results showed that the ultra-high-frequency thresholds were elevated and that there was reduction in the amplitudes of ultra-high-frequency OAEs in smokers. There was an increased risk of auditory damage with chronic smoking. The study results highlight the application of ultra-high-frequency OAEs and ultra-high-frequency audiometry for the early detection of auditory impairment. However, similar studies should be conducted on a larger population for better generalization of the results.

  18. High directivity optical antenna substrates for surface enhanced Raman scattering.

    Science.gov (United States)

    Wang, Dongxing; Zhu, Wenqi; Chu, Yizhuo; Crozier, Kenneth B

    2012-08-22

    A two-dimensional array of gold optical antennas integrated with a one-dimensional array of gold strips and mirrors is introduced and fabricated. The experimental results show that this design achieves average surface-enhanced Raman scattering (SERS) enhancement factors as high as 1.2 × 10(10) , which is more than two orders of magnitude larger than optical antennas without the gold strips and gold mirror.

  19. Electrophoretic High Molecular Weight DNA Purification Enables Optical Mapping

    OpenAIRE

    Maydan, Jason; THOMAS, Matthew; Tabanfar, Leyla; Mai, Laura; Poon, Hau-Ling; Pe, Joel; HAHN, KRISTEN; Goji, Noriko; Amoako, Kingsley; Marziali, Andre; Hanson, Dan

    2013-01-01

    Optical mapping generates an ordered restriction map from single, long DNA molecules. By overlapping restriction maps from multiple molecules, a physical map of entire chromosomes and genomes is constructed, greatly facilitating genome assembly in next generation sequencing projects, comparative genomics and strain typing. However, optical mapping relies on a method of preparing high quality DNA >250 kb in length, which can be challenging from some organisms and sample types. Here we demonstr...

  20. TOPICAL REVIEW: Optics of high-performance electron microscopes

    OpenAIRE

    H H Rose

    2008-01-01

    During recent years, the theory of charged particle optics together with advances in fabrication tolerances and experimental techniques has lead to very significant advances in high-performance electron microscopes. Here, we will describe which theoretical tools, inventions and designs have driven this development. We cover the basic theory of higher-order electron optics and of image formation in electron microscopes. This leads to a description of different methods to correct aberrations by...

  1. High Average Power Optical FEL Amplifiers

    CERN Document Server

    Ben-Zvi, I; Litvinenko, V

    2005-01-01

    Historically, the first demonstration of the FEL was in an amplifier configuration at Stanford University. There were other notable instances of amplifying a seed laser, such as the LLNL amplifier and the BNL ATF High-Gain Harmonic Generation FEL. However, for the most part FELs are operated as oscillators or self amplified spontaneous emission devices. Yet, in wavelength regimes where a conventional laser seed can be used, the FEL can be used as an amplifier. One promising application is for very high average power generation, for instance a 100 kW average power FEL. The high electron beam power, high brightness and high efficiency that can be achieved with photoinjectors and superconducting energy recovery linacs combine well with the high-gain FEL amplifier to produce unprecedented average power FELs with some advantages. In addition to the general features of the high average power FEL amplifier, we will look at a 100 kW class FEL amplifier is being designed to operate on the 0.5 ampere Energy Recovery Li...

  2. Potential programs for high sensitivity FIR spectroscopy with SPICA

    CERN Document Server

    Spinoglio, L; Saraceno, P; Spinoglio, Luigi; Giorgio, Anna Maria Di; Saraceno, Paolo

    2006-01-01

    We discuss the potential of high sensitivity mid-IR and far-IR spectroscopy to proof the physical properties of active nuclei and starburst regions of local and distant galaxies. For local galaxies, it will be possible to map the discs and ISM through the low ionization ionic lines and a variety of molecular tracers, such as OH, H2O and high-J CO. At increasing distance, most of the ionic nebular lines (typical of stars and AGNs) are shifted into the FIR, making possible to compare the observed spectra with those predicted by different evolutionary scenarios. At the very high redshift of 10-15, sensitive mid-to-far-IR spectrometers, such as those planned to be at the focal plane of the future SPICA mision, could be adequate to detect the H recombination lines excited in the HII regions around population III stars, if these stars happened to reside in large clusters of more than 10^5 members.

  3. High-sensitivity piezoelectric perovskites for magnetoelectric composites

    Science.gov (United States)

    Amorín, Harvey; Algueró, Miguel; Campo, Rubén Del; Vila, Eladio; Ramos, Pablo; Dollé, Mickael; Romaguera-Barcelay, Yonny; Cruz, Javier Pérez De La; Castro, Alicia

    2015-01-01

    A highly topical set of perovskite oxides are high-sensitivity piezoelectric ones, among which Pb(Zr,Ti)O3 at the morphotropic phase boundary (MPB) between ferroelectric rhombohedral and tetragonal polymorphic phases is reckoned a case study. Piezoelectric ceramics are used in a wide range of mature, electromechanical transduction technologies like piezoelectric sensors, actuators and ultrasound generation, to name only a few examples, and more recently for demonstrating novel applications like magnetoelectric composites. In this case, piezoelectric perovskites are combined with magnetostrictive materials to provide magnetoelectricity as a product property of the piezoelectricity and piezomagnetism of the component phases. Interfaces play a key issue, for they control the mechanical coupling between the piezoresponsive phases. We present here main results of our investigation on the suitability of the high sensitivity MPB piezoelectric perovskite BiScO3–PbTiO3 in combination with ferrimagnetic spinel oxides for magnetoelectric composites. Emphasis has been put on the processing at low temperature to control reactions and interdiffusion between the two oxides. The role of the grain size effects is extensively addressed. PMID:27877758

  4. High-Sensitivity Measurement of Density by Magnetic Levitation.

    Science.gov (United States)

    Nemiroski, Alex; Kumar, A A; Soh, Siowling; Harburg, Daniel V; Yu, Hai-Dong; Whitesides, George M

    2016-03-01

    This paper presents methods that use Magnetic Levitation (MagLev) to measure very small differences in density of solid diamagnetic objects suspended in a paramagnetic medium. Previous work in this field has shown that, while it is a convenient method, standard MagLev (i.e., where the direction of magnetization and gravitational force are parallel) cannot resolve differences in density mm) because (i) objects close in density prevent each other from reaching an equilibrium height due to hard contact and excluded volume, and (ii) using weaker magnets or reducing the magnetic susceptibility of the medium destabilizes the magnetic trap. The present work investigates the use of weak magnetic gradients parallel to the faces of the magnets as a means of increasing the sensitivity of MagLev without destabilization. Configuring the MagLev device in a rotated state (i.e., where the direction of magnetization and gravitational force are perpendicular) relative to the standard configuration enables simple measurements along the axes with the highest sensitivity to changes in density. Manipulating the distance of separation between the magnets or the lengths of the magnets (along the axis of measurement) enables the sensitivity to be tuned. These modifications enable an improvement in the resolution up to 100-fold over the standard configuration, and measurements with resolution down to 10(-6) g/cm(3). Three examples of characterizing the small differences in density among samples of materials having ostensibly indistinguishable densities-Nylon spheres, PMMA spheres, and drug spheres-demonstrate the applicability of rotated Maglev to measuring the density of small (0.1-1 mm) objects with high sensitivity. This capability will be useful in materials science, separations, and quality control of manufactured objects.

  5. High-speed adaptive interferometer for optical coherence-domain reflectometry through turbid media.

    Science.gov (United States)

    Peng, L; Yu, P; Nolte, D D; Melloch, M R

    2003-03-15

    Two-wave mixing in a dynamic holographic film acts as the adaptive beam combiner in a short-coherence interferometer that performs optical coherence-domain reflectometry (OCDR) through turbid media. This approach combines the high spatial resolution and sensitivity of coherence-domain reflectometry with photorefractive quantum-well-based adaptive homodyne detection. A depth resolution of 28 microm and penetration through 16 mean free paths in a turbid medium have been obtained in this adaptive OCDR application.

  6. Enhanced monolithic diffraction gratings with high efficiency and reduced polarization sensitivity for remote sensing applications

    Science.gov (United States)

    Triebel, Peter; Diehl, Torsten; Moeller, Tobias; Gatto, Alexandre; Pesch, Alexander; Erdmann, Lars H.; Burkhardt, Matthias; Kalies, Alexander

    2015-10-01

    Spectral imaging systems lead to enhanced sensing properties when the sensing system provides sufficient spectral resolution to identify materials from its spectral reflectance signature. The performance of diffraction gratings provides an initial way to improve instrumental resolution. Thus, subsequent manufacturing techniques of high quality gratings are essential to significantly improve the spectral performance. The ZEISS unique technology of manufacturing real-blazed profiles and as well as lamellar profiles comprising transparent substrates is well suited for the production of transmission gratings. In order to reduce high order aberrations, aspherical and free-form surfaces can be alternatively processed to allow more degrees of freedom in the optical design of spectroscopic instruments with less optical elements and therefore size and weight advantages. Prism substrates were used to manufacture monolithic GRISM elements for UV to IR spectral range. Many years of expertise in the research and development of optical coatings enable high transmission anti-reflection coatings from the DUV to the NIR. ZEISS has developed specially adapted coating processes (Ion beam sputtering, ion-assisted deposition and so on) for maintaining the micro-structure of blazed gratings in particular. Besides of transmission gratings, numerous spectrometer setups (e.g. Offner, Rowland circle, Czerny-Turner system layout) working on the optical design principles of reflection gratings. This technology steps can be applied to manufacture high quality reflection gratings from the EUV to the IR applications with an outstanding level of low stray light and ghost diffraction order by employing a combination of holography and reactive ion beam etching together with the in-house coating capabilities. We report on results of transmission gratings on plane and curved substrates and GRISM elements with enhanced efficiency of the grating itself combined with low scattered light in the angular

  7. Mode profiling of optical fibers at high laser powers

    DEFF Research Database (Denmark)

    Nielsen, Peter Carøe; Pedersen, David Bue; Simonsen, R.B.

    2008-01-01

    This paper describes the development of a measuring equipment capable of analysing the beam profile at high optical powers emitted by delivery fibers used in manufacturing processes. Together with the optical delivery system, the output beam quality from the delivery fiber and the shape...... of the focused spot can be determined. The analyser is based on the principle of a rotating wire being swept though the laser beam, while the reflected signal is recorded [1]. By changing the incident angle of the rotating rod from 0° to 360° in relation to the fiber, the full profile of the laser beam...... is obtained. Choosing a highly reflective rod material and a sufficiently high rotation speed, these measurements can be done with high laser powers, without any additional optical elements between the fiber and analyzer. The performance of the analyzer was evaluated by coupling laser light into different...

  8. Ultra-high accuracy optical testing: creating diffraction-limitedshort-wavelength optical systems

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Kenneth A.; Naulleau, Patrick P.; Rekawa, Senajith B.; Denham, Paul E.; Liddle, J. Alexander; Gullikson, Eric M.; Jackson, KeithH.; Anderson, Erik H.; Taylor, John S.; Sommargren, Gary E.; Chapman,Henry N.; Phillion, Donald W.; Johnson, Michael; Barty, Anton; Soufli,Regina; Spiller, Eberhard A.; Walton, Christopher C.; Bajt, Sasa

    2005-08-03

    Since 1993, research in the fabrication of extreme ultraviolet (EUV) optical imaging systems, conducted at Lawrence Berkeley National Laboratory (LBNL) and Lawrence Livermore National Laboratory (LLNL), has produced the highest resolution optical systems ever made. We have pioneered the development of ultra-high-accuracy optical testing and alignment methods, working at extreme ultraviolet wavelengths, and pushing wavefront-measuring interferometry into the 2-20-nm wavelength range (60-600 eV). These coherent measurement techniques, including lateral shearing interferometry and phase-shifting point-diffraction interferometry (PS/PDI) have achieved RMS wavefront measurement accuracies of 0.5-1-{angstrom} and better for primary aberration terms, enabling the creation of diffraction-limited EUV optics. The measurement accuracy is established using careful null-testing procedures, and has been verified repeatedly through high-resolution imaging. We believe these methods are broadly applicable to the advancement of short-wavelength optical systems including space telescopes, microscope objectives, projection lenses, synchrotron beamline optics, diffractive and holographic optics, and more. Measurements have been performed on a tunable undulator beamline at LBNL's Advanced Light Source (ALS), optimized for high coherent flux; although many of these techniques should be adaptable to alternative ultraviolet, EUV, and soft x-ray light sources. To date, we have measured nine prototype all-reflective EUV optical systems with NA values between 0.08 and 0.30 (f/6.25 to f/1.67). These projection-imaging lenses were created for the semiconductor industry's advanced research in EUV photolithography, a technology slated for introduction in 2009-13. This paper reviews the methods used and our program's accomplishments to date.

  9. Testing spatial α-variation with optical atomic clocks based on highly charged ions

    Directory of Open Access Journals (Sweden)

    Berengut J. C.

    2013-08-01

    Full Text Available We review recent works illustrating the potential use of highly charged ions as the basis of optical atomic clocks of exceptional accuracy and very high sensitivity to variation of the fine structure constant, α. The tendency towards large transition energies in highly charged ions can be overcome using level crossings, which allow transitions between different orbitals to be within the range of usual lasers. We present simple scaling laws that demonstrate reduced systematics that could be realised in highly charged ion clocks. Such clocks could allow us to corroborate astronomical studies that suggest a spatial gradient in values of α across the Universe.

  10. High pressure-sensitive gene expression in Lactobacillus sanfranciscensis

    Directory of Open Access Journals (Sweden)

    R.F. Vogel

    2005-08-01

    Full Text Available Lactobacillus sanfranciscensis is a Gram-positive lactic acid bacterium used in food biotechnology. It is necessary to investigate many aspects of a model organism to elucidate mechanisms of stress response, to facilitate preparation, application and performance in food fermentation, to understand mechanisms of inactivation, and to identify novel tools for high pressure biotechnology. To investigate the mechanisms of the complex bacterial response to high pressure we have analyzed changes in the proteome and transcriptome by 2-D electrophoresis, and by microarrays and real time PCR, respectively. More than 16 proteins were found to be differentially expressed upon high pressure stress and were compared to those sensitive to other stresses. Except for one apparently high pressure-specific stress protein, no pressure-specific stress proteins were found, and the proteome response to pressure was found to differ from that induced by other stresses. Selected pressure-sensitive proteins were partially sequenced and their genes were identified by reverse genetics. In a transcriptome analysis of a redundancy cleared shot gun library, about 7% of the genes investigated were found to be affected. Most of them appeared to be up-regulated 2- to 4-fold and these results were confirmed by real time PCR. Gene induction was shown for some genes up-regulated at the proteome level (clpL/groEL/rbsK, while the response of others to high hydrostatic pressure at the transcriptome level seemed to differ from that observed at the proteome level. The up-regulation of selected genes supports the view that the cell tries to compensate for pressure-induced impairment of translation and membrane transport.

  11. A cute and highly contrast-sensitive superposition eye : The diurnal owlfly Libelloides macaronius

    NARCIS (Netherlands)

    Belušič, Gregor; Pirih, Primož; Stavenga, Doekele G.

    The owlfly Libelloides macaronius (Insecta: Neuroptera) has large bipartite eyes of the superposition type. The spatial resolution and sensitivity of the photoreceptor array in the dorsofrontal eye part was studied with optical and electrophysiological methods. Using structured illumination

  12. A cute and highly contrast-sensitive superposition eye - the diurnal owlfly Libelloides macaronius

    NARCIS (Netherlands)

    Belusic, Gregor; Pirih, Primoz; Stavenga, Doekele G.; Belušič, Gregor; Pirih, Primož

    2013-01-01

    The owlfly Libelloides macaronius (Insecta: Neuroptera) has large bipartite eyes of the superposition type. The spatial resolution and sensitivity of the photoreceptor array in the dorsofrontal eye part was studied with optical and electrophysiological methods. Using structured illumination microsco

  13. Rituximab induction therapy in highly sensitized kidney transplant recipients

    Institute of Scientific and Technical Information of China (English)

    YIN Hang; WAN Hao; HU Xiao-peng; LI Xiao-bei; WANG Wei; LIU Hang; REN Liang; ZHANG Xiao-dong

    2011-01-01

    Background The number of highly sensitized patients is rising, and sensitization can lead to renal transplant failure.The present study aimed to investigate the safety and efficacy of renal transplantation following induction therapy with rituximab in highly sensitized kidney transplant recipients.Methods Seven highly sensitized kidney transplant recipients who underwent rituximab therapy from December 2008 to December 2009 were retrospectively analyzed. There were 3 men and 4 women, with a mean age of 38.5 years (range, 21-47 years). The duration of hemodialysis was 3-12 months, with a mean duration of 11 months. For 4 patients,this was the second transplant; the previous graft survival time was 2-11 years, with a mean survival time of 5.8 years. All the female recipients had history of multiple pregnancies, and all patients had previously received blood transfusions. All donors were men, with a mean age of 32.5 years (range, 25-37 years). In 2 of the 7 patients, both class I and class II of panel reactive antibody were high; the remaining 5 patients showed either high in class I or in class II of panel reactive antibody. The mean panel reactive antibody value was 31% for class I and 51% for class II respectively. The donors and the recipients had the same blood type, with low lymphocyte cytotoxicity ranging from 2% to 5%. The human leukocyte antigen (HLA) mismatch numbers were from 2 to 4. All patients received tacrolimus (0.1 mg·kg-1·d-1) and mycophenolate mofetil (750 mg twice per day) orally 3 days prior to surgery. All patients received a single dose of 600 mg rituximab (375 mg/m2) infusion on the day before surgery and polyclonal antibody (antithymocyte globulin) on the day of surgery.Postoperative creatinine, creatinine clearance rate, and occurrence of rejection by pathological biopsy confirmation were monitored.Results No patient had delayed graft function after surgery. Two patients had acute rejection, one on day 7 and the other on day 13 post

  14. Highly sensitive detection of Staphylococcus aureus directly from patient blood.

    Directory of Open Access Journals (Sweden)

    Padmapriya P Banada

    Full Text Available BACKGROUND: Rapid detection of bloodstream infections (BSIs can be lifesaving. We investigated the sample processing and assay parameters necessary for highly-sensitive detection of bloodstream bacteria, using Staphylococcus aureus as a model pathogen and an automated fluidic sample processing-polymerase chain reaction (PCR platform as a model diagnostic system. METHODOLOGY/PRINCIPAL FINDINGS: We compared a short 128 bp amplicon hemi-nested PCR and a relatively shorter 79 bp amplicon nested PCR targeting the S. aureus nuc and sodA genes, respectively. The sodA nested assay showed an enhanced limit of detection (LOD of 5 genomic copies per reaction or 10 colony forming units (CFU per ml blood over 50 copies per reaction or 50 CFU/ml for the nuc assay. To establish optimal extraction protocols, we investigated the relative abundance of the bacteria in different components of the blood (white blood cells (WBCs, plasma or whole blood, using the above assays. The blood samples were obtained from the patients who were culture positive for S. aureus. Whole blood resulted in maximum PCR positives with sodA assay (90% positive as opposed to cell-associated bacteria (in WBCs (71% samples positive or free bacterial DNA in plasma (62.5% samples positive. Both the assays were further tested for direct detection of S. aureus in patient whole blood samples that were contemporaneous culture positive. S. aureus was detected in 40/45 of culture-positive patients (sensitivity 89%, 95% CI 0.75-0.96 and 0/59 negative controls with the sodA assay (specificity 100%, 95% CI 0.92-1. CONCLUSIONS: We have demonstrated a highly sensitive two-hour assay for detection of sepsis causing bacteria like S. aureus directly in 1 ml of whole blood, without the need for blood culture.

  15. Polarization Sensitive Optical Coherence Tomography: A Review of Technology and Applications

    Directory of Open Access Journals (Sweden)

    Bernhard Baumann

    2017-05-01

    Full Text Available Polarization sensitive optical coherence tomography (PS-OCT is an imaging technique based on light scattering. PS-OCT performs rapid two- and three-dimensional imaging of transparent and translucent samples with micrometer scale resolution. PS-OCT provides image contrast based on the polarization state of backscattered light and has been applied in many biomedical fields as well as in non-medical fields. Thereby, the polarimetric approach enabled imaging with enhanced contrast compared to standard OCT and the quantitative assessment of sample polarization properties. In this article, the basic methodological principles, the state of the art of PS-OCT technologies, and important applications of the technique are reviewed in a concise yet comprehensive way.

  16. Planoconcave optical microresonator sensors for photoacoustic imaging: pushing the limits of sensitivity (Conference Presentation)

    Science.gov (United States)

    Guggenheim, James A.; Zhang, Edward Z.; Beard, Paul C.

    2016-03-01

    Most photoacoustic scanners use piezoelectric detectors but these have two key limitations. Firstly, they are optically opaque, inhibiting backward mode operation. Secondly, it is difficult to achieve adequate detection sensitivity with the small element sizes needed to provide near-omnidirectional response as required for tomographic imaging. Planar Fabry-Perot (FP) ultrasound sensing etalons can overcome both of these limitations and have proved extremely effective for superficial (heating. Finally, a prototype microresonator based photoacoustic scanner has been developed and applied to the problem of deep-tissue (>1cm) photoacoustic imaging in vivo. Imaging results for second generation microresonator sensors (with R = 99.5% and thickness up to ~800um) are compared to the best achievable with the planar FP sensors and piezoelectric receivers.

  17. Effects of laser frequency drift in phase-sensitive optical time-domain reflectometry fiber sensors

    CERN Document Server

    Zhirnov, Andrey; Stepanov, Konstantin; Nesterov, Evgeny; Karasik, Valery; Svelto, Cesare; Pnev, Alexey

    2016-01-01

    The present work studies the influence of laser frequency drifts on operating of phase-sensitive optical time-domain reflectometry ($\\Phi$-OTDR) fiber sensors. A mathematical model and numerical simulations are employed to highlight the influence of frequency drifts of light sources on two characteristic scales: large-time (minutes) and short-time (milliseconds) frequency drifts. Numerical simulation results are compared with predictions given by the fluctuation ratio coefficient (FRC), and they are in a qualitative agreement. In addition to qualitative criteria for light sources given by the FRC, quantitive requirements for optimal light sources for $\\Phi$-OTDR sensors are obtained. Numerical simulation results are verified by comparison with experimental data for three significantly different types of light source.

  18. Investigation of polarization-sensitive optical coherence tomography towards the study of microstructure of articular cartilage

    Science.gov (United States)

    Kasaragod, Deepa; Lu, Zenghai; Le Maitre, Christine; Wilkinson, J. Mark; Matcher, Stephen

    2013-03-01

    This paper highlights the extended Jones matrix calculus based multi-angle study carried out to understand the depth dependent structural orientation of the collagen fibers in articular cartilage using polarization-sensitive optical coherence tomography (PS-OCT). A 3D lamellar model for the collagen fiber orientation, with a quadratic profile for the arching of the collagen fibers in transitional zone which points towards an ordered arrangement of fibers in that zone is the basis of the organization architecture of collagen fibers in articular cartilage. Experimental data for both ex-vivo bovine fetlock and human patellar cartilage samples are compared with theoretical predictions, with a good quantitative agreement for bovine and a reasonable qualitative agreement for human articular cartilage samples being obtained

  19. Birefringence imaging of biological tissue by spectral domain polarization sensitive optical coherence tomography

    Science.gov (United States)

    Jing, Zhijun; Fan, Chuanmao; Jiang, Jingying; Gong, Qiang; Ma, Zhenhe; Zhang, Fan; Yao, Jianquan; Wang, R. K.

    2007-02-01

    A spectral domain Polarization sensitive optical coherence tomography (SDPS-OCT) system has been developed to acquire depth images of biological tissues such as porcine tendon, rabbit eye. The Stocks vectors (I, Q, U, and V) of the backscattered light from the biological tissues have been reconstructed. Further, the phase retardation and polarization degree between the two orthogonal polarizing states have been computed. Reconstructed images, i.e. birefringence images, from Stokes parameters, retardation and polarization degree of biological tissues show significant local variations in the polarization state. And the birefringence contrast of biological tissue possibly changes by some outside force. In addition, the local thickness of the birefringence layer determined with our system is significant. The results presented show SDPS-OCT is a potentially powerful technique to investigate tissue structural properties on the basis of the fact that any fibrous structure with biological tissues can influence the polarization state of light.

  20. Octopaminergic modulation of a fly visual motion-sensitive neuron during stimulation with naturalistic optic flow

    Directory of Open Access Journals (Sweden)

    Diana eRien

    2013-10-01

    Full Text Available In a variety of species locomotor activity, like walking or flying, has been demonstrated to alter visual information processing. The neuromodulator octopamine was shown to change the response characteristics of optic-flow processing neurons in the fly’s visual system in a similar way as locomotor activity. This modulation resulted in enhanced neuronal responses, in particular during sustained stimulation with high temporal frequencies, and in shorter latencies of responses to abrupt onsets of pattern motion. These state-dependent changes were interpreted to adjust neuronal tuning to the range of high velocities encountered during locomotion. Here we assess the significance of these changes for the processing of optic flow as experienced during flight. Naturalistic image sequences were reconstructed based on measurements of the head position and gaze direction of Calliphora vicina flying in an arena. We recorded the responses of the V1 neuron during presentation of these image sequences on a panoramic stimulus device (FliMax. Consistent with previous accounts, we found that spontaneous as well as stimulus-induced spike rates were increased by an octopamine agonist and decreased by an antagonist. Moreover, a small but consistent decrease in response latency upon octopaminergic activation was present, which might support fast responses to optic flow cues and limit instabilities during closed-loop optomotor regulation. However, apart from these effects the similarities between the dynamic response properties in the different pharmacologically induced states were surprisingly high, indicating that the processing of naturalistic optic flow is not fundamentally altered by octopaminergic modulation.